WorldWideScience

Sample records for uniform test method

  1. 10 CFR Appendix P to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Pool Heaters

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Pool Heaters 1. Test... 2.9 of ANSI Z21.56-1994. The measurement of energy consumption for oil-fired pool heaters in Btu is...

  2. 10 CFR Appendix B1 to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Freezers

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Freezers 1... temperature, then these test results shall be used to determine energy consumption. If the compartment...

  3. 10 CFR Appendix Q to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Fluorescent Lamp Ballasts

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... Appendix Q to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Fluorescent... reference; see § 430.3). The test for measuring standby mode energy consumption of fluorescent lamp ballasts...

  4. 10 CFR 431.107 - Uniform test method for the measurement of energy efficiency of commercial heat pump water...

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters. [Reserved] 431.107 Section 431.107 Energy DEPARTMENT OF....107 Uniform test method for the measurement of energy efficiency of commercial heat pump water heaters...

  5. 10 CFR Appendix S to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Faucets and Showerheads

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Water Consumption of... Appendix S to Subpart B of Part 430—Uniform Test Method for Measuring the Water Consumption of Faucets and... water consumption value shall be rounded to one decimal place for non-metered faucets, or two decimal...

  6. 10 CFR Appendix X to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Dehumidifiers

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption of Dehumidifiers X Appendix X to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY... Appendix X to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of...

  7. 10 CFR Appendix N to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Furnaces and Boilers

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... Appendix N to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Furnaces... average burner operating hours, average annual fuel energy consumption and average annual auxiliary...

  8. 10 CFR Appendix U to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Ceiling Fans

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Ceiling Fans 1. Scope... significant digits as the previous step. Round the final energy consumption value to the nearest whole number...

  9. 10 CFR 431.204 - Uniform test method for the measurement of energy consumption of illuminated exit signs.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform test method for the measurement of energy consumption of illuminated exit signs. 431.204 Section 431.204 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION... Procedures § 431.204 Uniform test method for the measurement of energy consumption of illuminated exit signs...

  10. 10 CFR 431.86 - Uniform test method for the measurement of energy efficiency of commercial packaged boilers.

    Science.gov (United States)

    2010-01-01

    ... efficiency of commercial packaged boilers. 431.86 Section 431.86 Energy DEPARTMENT OF ENERGY ENERGY... Boilers Test Procedures § 431.86 Uniform test method for the measurement of energy efficiency of... packaged boiler equipment classes. (B) On or after March 2, 2012, conduct the thermal efficiency test as...

  11. 10 CFR 431.106 - Uniform test method for the measurement of energy efficiency of commercial water heaters and hot...

    Science.gov (United States)

    2010-01-01

    ... efficiency of commercial water heaters and hot water supply boilers (other than commercial heat pump water... PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Commercial Water Heaters, Hot Water Supply Boilers and Unfired Hot Water Storage Tanks Test Procedures § 431.106 Uniform test method for the measurement...

  12. 10 CFR 431.76 - Uniform test method for the measurement of energy efficiency of commercial warm air furnaces.

    Science.gov (United States)

    2010-01-01

    ...) Measurement of flue CO 2 (carbon dioxide) for oil-fired commercial warm air furnaces. In addition to the flue... commercial warm air furnace. The test procedure for the measurement of the condensate from the flue gas under... 10 Energy 3 2010-01-01 2010-01-01 false Uniform test method for the measurement of energy...

  13. 10 CFR 431.224 - Uniform test method for the measurement of energy consumption for traffic signal modules and...

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform test method for the measurement of energy consumption for traffic signal modules and pedestrian modules. 431.224 Section 431.224 Energy DEPARTMENT OF... measurement of energy consumption for traffic signal modules and pedestrian modules. (a) Scope. This section...

  14. Uniform peanut performance test 2017

    Science.gov (United States)

    The Uniform Peanut Performance Tests (UPPT) are designed to evaluate the commercial potential of advanced breeding peanut lines not formally released. The tests are performed in ten locations across the peanut production belt. In this study, 2 controls and 14 entries were evaluated at 8 locations....

  15. 10 CFR Appendix T to Subpart B of... - Uniform Test Method for Measuring the Water Consumption of Water Closets and Urinals

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Water Consumption of... Appendix T to Subpart B of Part 430—Uniform Test Method for Measuring the Water Consumption of Water... previous step. The final water consumption value shall be rounded to one decimal place. b. The test...

  16. 10 CFR Appendix V to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Ceiling Fan Light Kits

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... Appendix V to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Ceiling Fan... the final energy consumption value to a whole number as follows: (i) A fractional number at or above...

  17. 10 CFR Appendix G to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Unvented Home Heating Equipment

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption..., App. G Appendix G to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of... energy consumption for primary electric heaters. For primary electric heaters, calculate the annual...

  18. Impact of Uniform Methods on Interlaboratory Antibody Titration Variability: Antibody Titration and Uniform Methods.

    Science.gov (United States)

    Bachegowda, Lohith S; Cheng, Yan H; Long, Thomas; Shaz, Beth H

    2017-01-01

    -Substantial variability between different antibody titration methods prompted development and introduction of uniform methods in 2008. -To determine whether uniform methods consistently decrease interlaboratory variation in proficiency testing. -Proficiency testing data for antibody titration between 2009 and 2013 were obtained from the College of American Pathologists. Each laboratory was supplied plasma and red cells to determine anti-A and anti-D antibody titers by their standard method: gel or tube by uniform or other methods at different testing phases (immediate spin and/or room temperature [anti-A], and/or anti-human globulin [AHG: anti-A and anti-D]) with different additives. Interlaboratory variations were compared by analyzing the distribution of titer results by method and phase. -A median of 574 and 1100 responses were reported for anti-A and anti-D antibody titers, respectively, during a 5-year period. The 3 most frequent (median) methods performed for anti-A antibody were uniform tube room temperature (147.5; range, 119-159), uniform tube AHG (143.5; range, 134-150), and other tube AHG (97; range, 82-116); for anti-D antibody, the methods were other tube (451; range, 431-465), uniform tube (404; range, 382-462), and uniform gel (137; range, 121-153). Of the larger reported methods, uniform gel AHG phase for anti-A and anti-D antibodies had the most participants with the same result (mode). For anti-A antibody, 0 of 8 (uniform versus other tube room temperature) and 1 of 8 (uniform versus other tube AHG), and for anti-D antibody, 0 of 8 (uniform versus other tube) and 0 of 8 (uniform versus other gel) proficiency tests showed significant titer variability reduction. -Uniform methods harmonize laboratory techniques but rarely reduce interlaboratory titer variance in comparison with other methods.

  19. An efficient, maintenance free and approved method for spectroscopic control and monitoring of blend uniformity: The moving F-test.

    Science.gov (United States)

    Besseling, Rut; Damen, Michiel; Tran, Thanh; Nguyen, Thanh; van den Dries, Kaspar; Oostra, Wim; Gerich, Ad

    2015-10-10

    Dry powder mixing is a wide spread Unit Operation in the Pharmaceutical industry. With the advent of in-line Near Infrared (NIR) Spectroscopy and Quality by Design principles, application of Process Analytical Technology to monitor Blend Uniformity (BU) is taking a more prominent role. Yet routine use of NIR for monitoring, let alone control of blending processes is not common in the industry, despite the improved process understanding and (cost) efficiency that it may offer. Method maintenance, robustness and translation to regulatory requirements have been important barriers to implement the method. This paper presents a qualitative NIR-BU method offering a convenient and compliant approach to apply BU control for routine operation and process understanding, without extensive calibration and method maintenance requirements. The method employs a moving F-test to detect the steady state of measured spectral variances and the endpoint of mixing. The fundamentals and performance characteristics of the method are first presented, followed by a description of the link to regulatory BU criteria, the method sensitivity and practical considerations. Applications in upscaling, tech transfer and commercial production are described, along with evaluation of the method performance by comparison with results from quantitative calibration models. A full application, in which end-point detection via the F-test controls the blending process of a low dose product, was successfully filed in Europe and Australia, implemented in commercial production and routinely used for about five years and more than 100 batches. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. 10 CFR Appendix M to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... Consumption of Central Air Conditioners and Heat Pumps 1. DEFINITIONS 2. TESTING CONDITIONS 2.1Test room... more common ducts within each test room that contains multiple indoor coils. At the plane where each...

  1. An innovative validated spectrofluorimetric method for determination of Lisinopril in presence of hydrochlorothiazide; application to content uniformity testing

    Science.gov (United States)

    Derayea, Sayed M.; Badr El-din, Khalid M.; Mohammed, Fatma F.

    2018-01-01

    A new sensitive and discriminating spectrofluorimetric method has been developed and validated for determination of Lisinopril, one of the angiotensin converting enzyme inhibitors, in its pure bulk form and pharmaceutical tablets. The reaction of Lisinopril with ethylacetoacetate and formaldehyde in acidic buffered medium (pH 3.8) has yielded a pale yellow product that exhibited a high fluorescence measured at 438 nm after excitation at 350 nm. All the experimental parameters affecting the formation and stability of the produced fluorophore were carefully investigated and optimized to give the maximum sensitivity. The fluorescence intensity was directly proportional to the drug concentration in the range of 0.5-4.5 μg/mL with a limit of detection equal to 0.16 μg/mL. The method was successfully applied in the analysis of the commercially available pharmaceutical tablets containing the single drug or its binary mixtures with Hydrochlorothiazide. Furthermore, the developed procedure was adapted for studying the content uniformity test of some dosage forms containing the cited drug.

  2. 10 CFR Appendix F to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Room Air Conditioners

    Science.gov (United States)

    2010-01-01

    ... of Room Air Conditioners F Appendix F to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY... Conditioners 1. Test method. The test method for testing room air conditioners shall consist of application of the methods and conditions in American National Standard (ANS) Z234.1-1972, “Room Air Conditioners...

  3. 10 CFR Appendix J1 to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Automatic and Semi-Automatic Clothes...

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... Energy Consumption of Automatic and Semi-Automatic Clothes Washers The provisions of this appendix J1... means for determining the energy consumption of a clothes washer with an adaptive control system...

  4. 10 CFR Appendix J to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Automatic and Semi-Automatic Clothes...

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption.... Note: Appendix J does not provide a means for determining the energy consumption of a clothes washer... divided by the total clothes washer energy consumption per cycle, with such energy consumption expressed...

  5. 10 CFR 431.304 - Uniform test method for the measurement of energy consumption of walk-in coolers and walk-in...

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform test method for the measurement of energy consumption of walk-in coolers and walk-in freezers. 431.304 Section 431.304 Energy DEPARTMENT OF ENERGY... measuring, pursuant to EPCA, the energy consumption of refrigerated bottled or canned beverage vending...

  6. 10 CFR Appendix W to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Medium Base Compact Fluorescent Lamps

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption of Medium Base Compact Fluorescent Lamps W Appendix W to Subpart B of Part 430 Energy DEPARTMENT OF... the previous step. Round the final energy consumption value, as applicable, to the nearest decimal...

  7. 10 CFR 431.294 - Uniform test method for the measurement of energy consumption of refrigerated bottled or canned...

    Science.gov (United States)

    2010-01-01

    ... consumption of refrigerated bottled or canned beverage vending machines. 431.294 Section 431.294 Energy... method for the measurement of energy consumption of refrigerated bottled or canned beverage vending... test procedure for energy consumption of refrigerated bottled or canned beverage vending machines shall...

  8. 10 CFR Appendix Y to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Battery Chargers

    Science.gov (United States)

    2010-01-01

    ... Requirements,” append this sentence to the end: “The test equipment must be capable of accounting for crest factor and frequency spectrum in its measurement of the UUT input current.” 4. Test Measurement: (a) Inactive Mode Energy Consumption Measurement. The measurement of the battery charger energy ratio shall...

  9. 10 CFR Appendix D to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Clothes Dryers

    Science.gov (United States)

    2010-01-01

    ... CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. D... the door plane and the loading port. Record the temperature of the water and then the weight of the...

  10. 10 CFR Appendix I to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Conventional Ranges, Conventional...

    Science.gov (United States)

    2010-01-01

    ... PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. I Appendix I to Subpart B of Part... between the center and the corners of the conventional gas oven on the diagonals of a horizontal plane...

  11. 10 CFR Appendix A to Subpart K of... - Uniform Test Method for Measuring the Energy Consumption of Distribution Transformers

    Science.gov (United States)

    2010-01-01

    ... Measured quantity Test systemaccuracy Power Losses ± 3.0% Voltage ± 0.5% Current ± 0.5% Resistance ± 0.5... and then take simultaneous readings of voltage and current. Determine the winding resistance Rdc by... resistance measurements: (a) Use separate current and voltage leads when measuring small (< 10 ohms...

  12. 10 CFR 431.64 - Uniform test method for the measurement of energy consumption of commercial refrigerators...

    Science.gov (United States)

    2010-01-01

    ... consumption of commercial refrigerators, freezers, and refrigerator-freezers. 431.64 Section 431.64 Energy... method for the measurement of energy consumption of commercial refrigerators, freezers, and refrigerator... energy consumption in kilowatt hours per day (kWh/day) for a given product category and volume or total...

  13. Development of a chromatographic method with multi-criteria decision making design for simultaneous determination of nifedipine and atenolol in content uniformity testing.

    Science.gov (United States)

    Ahmed, Sameh; Alqurshi, Abdulmalik; Mohamed, Abdel-Maaboud Ismail

    2018-07-01

    A new robust and reliable high-performance liquid chromatography (HPLC) method with multi-criteria decision making (MCDM) approach was developed to allow simultaneous quantification of atenolol (ATN) and nifedipine (NFD) in content uniformity testing. Felodipine (FLD) was used as an internal standard (I.S.) in this study. A novel marriage between a new interactive response optimizer and a HPLC method was suggested for multiple response optimizations of target responses. An interactive response optimizer was used as a decision and prediction tool for the optimal settings of target responses, according to specified criteria, based on Derringer's desirability. Four independent variables were considered in this study: Acetonitrile%, buffer pH and concentration along with column temperature. Eight responses were optimized: retention times of ATN, NFD, and FLD, resolutions between ATN/NFD and NFD/FLD, and plate numbers for ATN, NFD, and FLD. Multiple regression analysis was applied in order to scan the influences of the most significant variables for the regression models. The experimental design was set to give minimum retention times, maximum resolution and plate numbers. The interactive response optimizer allowed prediction of optimum conditions according to these criteria with a good composite desirability value of 0.98156. The developed method was validated according to the International Conference on Harmonization (ICH) guidelines with the aid of the experimental design. The developed MCDM-HPLC method showed superior robustness and resolution in short analysis time allowing successful simultaneous content uniformity testing of ATN and NFD in marketed capsules. The current work presents an interactive response optimizer as an efficient platform to optimize, predict responses, and validate HPLC methodology with tolerable design space for assay in quality control laboratories. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Development and validation of a new spectrofluorimetric method for the determination of some beta-blockers through fluorescence quenching of eosin Y. Application to content uniformity test

    Directory of Open Access Journals (Sweden)

    Derayea Sayed M

    2016-01-01

    Full Text Available A simple, rapid, sensitive and economic spectrofluorimetric method has been developed and validated for determination of some β-adrenergic blocking agents namely; betaxolol hydrochloride (BTX, carvedilol (CAR, labetalol hydrochloride (LBT, nebivolol hydrochloride (NEB and propranolol hydrochloride (PRO. The method is based on the quenching effect of the cited drugs on the fluorescence intensity of eosin Y at pH 3.4 (acetate buffer. The fluorescence quenching is due to the formation of an ion-pair complex and was measured without extraction at 545 nm (λex. 301.5 nm. The factors affecting the formation of the ion-pair complex were carefully studied and optimized. Under the optimal conditions, the linear ranges for the relationship between the fluorescence quenching value and the concentration of the investigated drugs were 100-2500, 150-2500 and 50-2250 ng mL-1 for (BTX, CAR, (LBT, NEB and (PRO respectively. The method was validated according to ICH guidelines and was applied for determination of the cited drugs in pharmaceutical dosage forms with excellent recoveries. In addition, content uniformity testing of some commercial dosage forms was checked by the proposed method.

  15. Highly Sensitive Micellar Enhanced Spectrofluorimetric Method for Determination of Mirtazapine in Tablets and Human Urine: Application to In Vitro Drug Release and Content Uniformity Test

    Directory of Open Access Journals (Sweden)

    Hany W. Darwish

    2016-01-01

    Full Text Available A highly sensitive and simple micelle enhanced spectrofluorimetric method was developed for assaying mirtazapine (MRZ in REMERON® tablets and spiked human urine directly without the need of derivatizing agent. The basis of the current procedure is the examination of the relative fluorescence intensity (RFI of MRZ in sodium lauryl sulphate (SLS micellar medium. The RFI of MRZ in water was enhanced markedly on addition of SLS. The RFI was measured at 403 nm after excitation at 320 nm. The fluorescence-concentration relationship was linear over the range 1–500 ng/mL, with lower detection limit of 0.399 ng/mL. The proposed method was successfully applied to the determination of MRZ in dosage form and spiked human urine. Recovery percentages of MRZ utilizing the current method were 99.05±1.83, 98.37±1.96, and 100.41±2.61% for pure powder, pharmaceutical dosage form, and spiked human urine, respectively. The application of the proposed method was extended to test content uniformity and the in vitro drug release of REMERON tablets, according to USP guidelines.

  16. A simple uniformity test for ultrasound phased arrays.

    Science.gov (United States)

    Dudley, Nicholas J; Woolley, Darren J

    2016-09-01

    It is difficult to test phased array ultrasound transducers for non functioning elements. We aimed to modify a widely performed test to improve its ease and effectiveness for these arrays. A paperclip was slowly moved along the transducer array, with the scanner operating in M-mode, imaging at a fundamental frequency with automatic gain and grey scale adjustment disabled. Non-functioning elements are identified by a dark vertical line in the image. The test was repeated several times for each transducer, looking for consistency of results. 2 transducers, with faults already shown by electronic transducer testing, were used to validate the method. 23 transducers in clinical use were tested. The results of the modified test on the 2 faulty transducers agreed closely with electronic transducer testing results. The test indicated faults in 5 of the 23 transducers in clinical use: 3 with a single failed element and 2 with non-uniform sensitivity. 1 transducer with non-uniform sensitivity had undergone lens repair; the new lens was visibly non-uniform in thickness and further testing showed a reduction in depth of penetration and a loss of elevational focus in comparison with a new transducer. The modified test is capable of detecting non-functioning elements. Further work is required to provide a better understanding of more subtle faults. Copyright © 2016 Associazione Italiana di Fisica Medica. All rights reserved.

  17. Preparation of uniform porous hydroxyapatite biomaterials by a new method

    International Nuclear Information System (INIS)

    Tang Yuejun; Tang Yuefeng; Lv Chuntang; Zhou Zhonghua

    2008-01-01

    In this paper, a new method of preparation of uniform porous hydroxyapatite biomaterials was reported. In order to obtain uniform porous biomaterials, disk samples were formed by the mixture of hydroxyapatite (HAP) powders and monodispersed polystyrene microspheres, and then HAP uniform porous materials with different diameter and different porosity (diameter: 436 ± 25 nm, 892 ± 20 nm and 1890 ± 20 nm, porosity: 46.5%, 41.3% and 34.7%, respectively) were prepared by sintering these disk samples at 1250 deg. C for 5 h. The pure phase of HAP powders fabricated by the hydrothermal technology was confirmed by X-ray diffraction (XRD). The surface and size distribution of pores in HAP biomaterials were observed by scanning electron microscopy (SEM), and the pore size distribution in porous HAP biomaterials was tested by mercury intrusion method

  18. Uniform Sampling Table Method and its Applications II--Evaluating the Uniform Sampling by Experiment.

    Science.gov (United States)

    Chen, Yibin; Chen, Jiaxi; Chen, Xuan; Wang, Min; Wang, Wei

    2015-01-01

    A new method of uniform sampling is evaluated in this paper. The items and indexes were adopted to evaluate the rationality of the uniform sampling. The evaluation items included convenience of operation, uniformity of sampling site distribution, and accuracy and precision of measured results. The evaluation indexes included operational complexity, occupation rate of sampling site in a row and column, relative accuracy of pill weight, and relative deviation of pill weight. They were obtained from three kinds of drugs with different shape and size by four kinds of sampling methods. Gray correlation analysis was adopted to make the comprehensive evaluation by comparing it with the standard method. The experimental results showed that the convenience of uniform sampling method was 1 (100%), odds ratio of occupation rate in a row and column was infinity, relative accuracy was 99.50-99.89%, reproducibility RSD was 0.45-0.89%, and weighted incidence degree exceeded the standard method. Hence, the uniform sampling method was easy to operate, and the selected samples were distributed uniformly. The experimental results demonstrated that the uniform sampling method has good accuracy and reproducibility, which can be put into use in drugs analysis.

  19. Uniformity testing: assessment of a centralized web-based uniformity analysis system.

    Science.gov (United States)

    Klempa, Meaghan C

    2011-06-01

    Uniformity testing is performed daily to ensure adequate camera performance before clinical use. The aim of this study is to assess the reliability of Beth Israel Deaconess Medical Center's locally built, centralized, Web-based uniformity analysis system by examining the differences between manufacturer and Web-based National Electrical Manufacturers Association integral uniformity calculations measured in the useful field of view (FOV) and the central FOV. Manufacturer and Web-based integral uniformity calculations measured in the useful FOV and the central FOV were recorded over a 30-d period for 4 cameras from 3 different manufacturers. These data were then statistically analyzed. The differences between the uniformity calculations were computed, in addition to the means and the SDs of these differences for each head of each camera. There was a correlation between the manufacturer and Web-based integral uniformity calculations in the useful FOV and the central FOV over the 30-d period. The average differences between the manufacturer and Web-based useful FOV calculations ranged from -0.30 to 0.099, with SD ranging from 0.092 to 0.32. For the central FOV calculations, the average differences ranged from -0.163 to 0.055, with SD ranging from 0.074 to 0.24. Most of the uniformity calculations computed by this centralized Web-based uniformity analysis system are comparable to the manufacturers' calculations, suggesting that this system is reasonably reliable and effective. This finding is important because centralized Web-based uniformity analysis systems are advantageous in that they test camera performance in the same manner regardless of the manufacturer.

  20. Methods for obtaining a uniform volume concentration of implanted ions

    International Nuclear Information System (INIS)

    Reutov, V.F.

    1995-01-01

    Three simple practical methods of irradiations with high energy particles providing the conditions for obtaining a uniform volume concentration of the implanted ions in the massive samples are described in the present paper. Realization of the condition of two-sided irradiation of a plane sample during its rotation in the flux of the projectiles is the basis of the first method. The use of free air as a filter with varying absorbent ability due to movement of the irradiated sample along ion beam brought to the atmosphere is at the basis of the second method of uniform ion alloying. The third method for obtaining a uniform volume concentration of the implanted ions in a massive sample consists of irradiation of a sample through the absorbent filter in the shape of a foil curved according to the parabolic law moving along its surface. The first method is the most effective for obtaining a great number of the samples, for example, for mechanical tests, the second one - for irradiation in different gaseous media, and the third one - for obtaining high concentrations of the implanted ions under controlled (regulated) thermal and deformation conditions. 2 refs., 7 figs

  1. Expedited, uniform processing of multi-vendor gamma test data

    International Nuclear Information System (INIS)

    Zimmerman, R.E.

    2002-01-01

    Aim: Acceptance testing of gamma camera performance is time consuming. When data is collected from different vendors image format and methodology differences can result in disjointed and difficult to compare results. Even when performing NEMA specified tests consistent processing of data from multi-vendor cameras results in methodological inconsistencies. A more uniform and consistent method to process data collected from gamma cameras would be a boon to those involved in acquiring and processing such test data. Methods and Materials: Image J is an image processing program freely available on the Web at http://rsb.info.nih.gov/ij/. It can be run using a normal Web browser or installed on any computer. Since it is written in Java it is platform and operating system independent. Image J is very extensible, object based and has a large international user community in many imaging disciplines. Extensions to Image J are written using the Java programming language and the internal macro recording facility. Image J handles multiple image formats useful in nuclear medicine including DICOM, RAW, BMP, JPG, Interfile, AVI and QT. Extensions have been written to process and determine gamma camera intrinsic and extrinsic uniformity, COR errors, planar extrinsic resolution and reconstructed spatial resolution. The testing and processing adhere closely to NEMA specified procedures and result in quantitative measures of performance traceable to NEMA and manufacturers specifications. Results and Conclusions: Extensions to Image J written specifically to process gamma camera acceptance test data have resulted in considerable decrease in time to complete the analysis and allows a consistent, vendor independent, method to measure performance of cameras from multiple vendors. Quality control images from multiple camera vendors are also easily processed in a consistent fashion. The availability of this or similar platform and vendor independent software should lead to more complete

  2. Alternative methods for evaluation of non-uniformity in nuclear medicine images

    International Nuclear Information System (INIS)

    Rasaneh, S.; Rajabi, H.; Hajizadeh, E.

    2005-01-01

    Non-uniformity test is the most essential in daily quality control procedures of nuclear medicine equipment's. However, the calculation of non-uniformity is hindered due to high level of noise in nuclear medicine data. Non-uniformity may be considered as a type of systematic error while noise is certainly a random error. The present methods of uniformity evaluation are not able to distinguish between systematic and random error and therefore produce incorrect results when noise is significant. In the present study, two hypothetical methods have been tested for evaluation of non-uniformity in nuclear medicine images. Materials and Methods: Using the Monte Carlo method, uniform and non-uniform flood images of different matrix sizes and different counts were generated. The uniformity of the images was calculated using the conventional method and proposed methods. The results were compared with the known non-uniformity data of simulated images. Results: It was observed that the value of integral uniformity never went below the recommended values except in small matrix size of high counts (more than 80 millions counts). The differential uniformity was quite insensitive to the degree of non-uniformity in large matrix size. Matrix size of 64*64 was only found to be suitable for the calculation of differential uniformity. It was observed that in uniform images, a small amount of non-uniformity changes the p-value of Kolmogorov-Smirnov test and noise amplitude of fast fourier transformation test significantly while the conventional methods failed to detect the nonuniformity. Conclusion: The conventional methods do not distinguish noise, which is always present in the data and occasional non-uniformity at low count density. In a uniform intact flood image, the difference between maximum and minimum pixel count (the value of integral uniformity) is much more than the recommended values for non-uniformity. After filtration of image, this difference decreases, but remains high

  3. Flood field uniformity testing - effects of crystal hydration

    International Nuclear Information System (INIS)

    Dimcheva, M.; Sergieva, S.; Doldurova, M.; Jovanovska, A.

    2012-01-01

    The most basic and sensitive routine quality control (QC) of gamma camera is that of intrinsic flood-field uniformity. The routine QC test must be assessed daily and any nonuniformity must be eliminated before patient testing to eliminate artifacts and false positive or false-negative patient results. The purpose of this study was to compare uniformity analysis results for scintillation crystal hydration with symmetric and asymmetric energy window on the Siemens Symbia T2 SPECTCT camera. Integral and differential uniformity analysis was performed by placing a point source 99m Tc in front of the detector with removed collimator to measure the effect of correction matrix, a count rate and activity volume on intrinsic uniformity. A 15% energy window set symmetrically over the 99m Tc photo peak is equivalent to 140±10% keV or a window spanning 126-154 keV. The results, received from Detector 2 gave the following uniformity parameter values: Both asymmetric energy window images show clearly multiple focal spots due to crystal hydration: discrete hot spots in the asymmetric low window image and discrete cold spots in the asymmetric high window image. The above results are not seen yet on the symmetric window image. We had replaced Detector 2 in order to avoid spots become visible in flood images obtained with the clinical energy window. The uniformity of a gamma camera is maybe the most important parameter that expresses the quality of the camera's performance. Non uniform areas in the field of view can result in misdiagnosed patients and low quality of clinical services. (authors)

  4. 10 CFR Appendix O to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Vented Home Heating Equipment

    Science.gov (United States)

    2010-01-01

    ... ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B... an integral draft diverter, install nine thermocouples, wired in parallel, in a horizontal plane in... thermocouples along imaginary lines intersecting at right angles in this horizontal plane at points one third...

  5. 10 CFR Appendix R to Subpart B of... - Uniform Test Method for Measuring Average Lamp Efficacy (LE), Color Rendering Index (CRI), and...

    Science.gov (United States)

    2010-01-01

    ... (LE), Color Rendering Index (CRI), and Correlated Color Temperature (CCT) of Electric Lamps R Appendix R to Subpart B of Part 430 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CONSERVATION PROGRAM FOR CONSUMER PRODUCTS Test Procedures Pt. 430, Subpt. B, App. R Appendix R to Subpart B of Part...

  6. Nondestructive testing method

    International Nuclear Information System (INIS)

    Porter, J.F.

    1996-01-01

    Nondestructive testing (NDT) is the use of physical and chemical methods for evaluating material integrity without impairing its intended usefulness or continuing service. Nondestructive tests are used by manufaturer's for the following reasons: 1) to ensure product reliability; 2) to prevent accidents and save human lives; 3) to aid in better product design; 4) to control manufacturing processes; and 5) to maintain a uniform quality level. Nondestructive testing is used extensively on power plants, oil and chemical refineries, offshore oil rigs and pipeline (NDT can even be conducted underwater), welds on tanks, boilers, pressure vessels and heat exchengers. NDT is now being used for testing concrete and composite materials. Because of the criticality of its application, NDT should be performed and the results evaluated by qualified personnel. There are five basic nondestructive examination methods: 1) liquid penetrant testing - method used for detecting surface flaws in materials. This method can be used for metallic and nonmetallic materials, portable and relatively inexpensive. 2) magnetic particle testing - method used to detect surface and subsurface flaws in ferromagnetic materials; 3) radiographic testing - method used to detect internal flaws and significant variation in material composition and thickness; 4) ultrasonic testing - method used to detect internal and external flaws in materials. This method uses ultrasonics to measure thickness of a material or to examine the internal structure for discontinuities. 5) eddy current testing - method used to detect surface and subsurface flaws in conductive materials. Not one nondestructive examination method can find all discontinuities in all of the materials capable of being tested. The most important consideration is for the specifier of the test to be familiar with the test method and its applicability to the type and geometry of the material and the flaws to be detected

  7. Influencing factors of GaN growth uniformity through orthogonal test analysis

    International Nuclear Information System (INIS)

    Zhang, Zhi; Fang, Haisheng; Yan, Han; Jiang, Zhimin; Zheng, Jiang; Gan, Zhiyin

    2015-01-01

    Gallium nitride (GaN) is widely used in light-emitting diode (LED) devices due to its wide bandgap and excellently optoelectronic performance. The efficiency and lifetime of LEDs are critically determined by quality of GaN, for example, growth uniformity. Metal-organic chemical vapor deposition (MOCVD) is the most popular technique to grow high-quality GaN epitaxial layers. Growth uniformity is influenced by fluid flow, heat transfer and chemical reactions in the reactor. In this paper, the growth process in a close-coupled showerhead (CCS) MOCVD reactor is investigated based on 3D numerical simulation. Influences of the operating parameters on the growth uniformity are presented. To evaluate the role of the parameters systematically and efficiently on the growth uniformity, orthogonal test method is introduced. The results reveal that the growth rate and uniformity are strongly related to the total gas flow rate, the showerhead height and the inlet gas temperature, but are weakly affected by the isothermal wall temperature, the rotating speed and the susceptor temperature under the ranges of the current study. The optimized combination of the parameters is further proposed as a useful reference for obtaining the LED layers with a balance between the growth rate and the growth uniformity in industry. - Highlights: • Fluid flow, heat transfer, chemical reactions are calculated for a 3D CCS reactor. • The effects of process parameters on growth rate and uniformity are investigated. • Orthogonal test method is introduced to analyze the effect of multi-factors. • Optimal combinations can be obtained for the best growth rate and uniformity.

  8. Test stand for non-uniformity correction of microbolometer focal plane arrays used in thermal cameras

    Science.gov (United States)

    Krupiński, Michał; Bareła, Jaroslaw; Firmanty, Krzysztof; Kastek, Mariusz

    2013-10-01

    Uneven response of particular detectors (pixels) to the same incident power of infrared radiation is an inherent feature of microbolometer focal plane arrays. As a result an image degradation occurs, known as Fixed Pattern Noise (FPN), which distorts the thermal representation of an observed scene and impairs the parameters of a thermal camera. In order to compensate such non-uniformity, several NUC correction methods are applied in digital data processing modules implemented in thermal cameras. Coefficients required to perform the non-uniformity correction procedure (NUC coefficients) are determined by calibrating the camera against uniform radiation sources (blackbodies). Non-uniformity correction is performed in a digital processing unit in order to remove FPN pattern in the registered thermal images. Relevant correction coefficients are calculated on the basis of recorded detector responses to several values of radiant flux emitted from reference IR radiation sources (blackbodies). The measurement of correction coefficients requires specialized setup, in which uniform, extended radiation sources with high temperature stability are one of key elements. Measurement stand for NUC correction developed in Institute of Optoelectronics, MUT, comprises two integrated extended blackbodies with the following specifications: area 200×200 mm, stabilized absolute temperature range +15 °C÷100 °C, and uniformity of temperature distribution across entire surface +/-0.014 °C. Test stand, method used for the measurement of NUC coefficients and the results obtained during the measurements conducted on a prototype thermal camera will be presented in the paper.

  9. Sagagd method for the beam shaping of uniform illumination

    International Nuclear Information System (INIS)

    Li Yongping; Chen Dewei; Wang Wei

    2002-01-01

    The simulated annealing algorithm, the genetic and the gradient descent algorithm are retrospectively and successfully amalgamated to optimal design of pure phase element for uniform beams. The process of this method is divided into three steps, first the energy enhancement of the main lobe, then the process to make the top of the main lobe to be smooth and the fringe to be steep, at last the full optimization beam. After these three steps of optimization, the beam is good enough to be applied to ICF

  10. An efficient shutter-less non-uniformity correction method for infrared focal plane arrays

    Science.gov (United States)

    Huang, Xiyan; Sui, Xiubao; Zhao, Yao

    2017-02-01

    The non-uniformity response in infrared focal plane array (IRFPA) detectors has a bad effect on images with fixed pattern noise. At present, it is common to use shutter to prevent from radiation of target and to update the parameters of non-uniformity correction in the infrared imaging system. The use of shutter causes "freezing" image. And inevitably, there exists the problems of the instability and reliability of system, power consumption, and concealment of infrared detection. In this paper, we present an efficient shutter-less non-uniformity correction (NUC) method for infrared focal plane arrays. The infrared imaging system can use the data gaining in thermostat to calculate the incident infrared radiation by shell real-timely. And the primary output of detector except the shell radiation can be corrected by the gain coefficient. This method has been tested in real infrared imaging system, reaching high correction level, reducing fixed pattern noise, adapting wide temperature range.

  11. Philosophy, design and testing of a uniform applied load flat plate testing machine

    International Nuclear Information System (INIS)

    Quirk, A.; Crook, C.

    1976-08-01

    The presence of a central crack, and its associated plastic zones may significantly affect distribution of the stress applied by a loading machine, to a test plate. As a result the fracture stress may be affected, usually optimistically. Examples of these effects are discussed. The design of a machine in which the load is uniformly applied to the test specimen is described and preliminary test data presented. (author)

  12. Non-uniform sampling and wide range angular spectrum method

    International Nuclear Information System (INIS)

    Kim, Yong-Hae; Byun, Chun-Won; Oh, Himchan; Lee, JaeWon; Pi, Jae-Eun; Heon Kim, Gi; Lee, Myung-Lae; Ryu, Hojun; Chu, Hye-Yong; Hwang, Chi-Sun

    2014-01-01

    A novel method is proposed for simulating free space field propagation from a source plane to a destination plane that is applicable for both small and large propagation distances. The angular spectrum method (ASM) was widely used for simulating near field propagation, but it caused a numerical error when the propagation distance was large because of aliasing due to under sampling. Band limited ASM satisfied the Nyquist condition on sampling by limiting a bandwidth of a propagation field to avoid an aliasing error so that it could extend the applicable propagation distance of the ASM. However, the band limited ASM also made an error due to the decrease of an effective sampling number in a Fourier space when the propagation distance was large. In the proposed wide range ASM, we use a non-uniform sampling in a Fourier space to keep a constant effective sampling number even though the propagation distance is large. As a result, the wide range ASM can produce simulation results with high accuracy for both far and near field propagation. For non-paraxial wave propagation, we applied the wide range ASM to a shifted destination plane as well. (paper)

  13. Uniform relativistic universe models with pressure. Part 2. Observational tests

    International Nuclear Information System (INIS)

    Krempec, J.; Krygier, B.

    1977-01-01

    The magnitude-redshift and angular diameter-redshift relations are discussed for the uniform (homogeneous and isotropic) relativistic Universe models with pressure. The inclusion of pressure into the energy-momentum tensor has given larger values of the deceleration parameter q. An increase of the deceleration parameter has led to the brightening of objects as well as to a little larger angular diameters. (author)

  14. Uniform irradiation system using beam scanning method for cyclotron

    International Nuclear Information System (INIS)

    Agematsu, Takashi; Okumura, Susumu; Arakawa, Kazuo

    1994-03-01

    JAERI AVF-cyclotron is equipped with an ion beam scanner for large area irradiation. The two-dimensional fluence distribution of ion beam obtained using cellulose triacetate film dosimeter was not uniform. This is resulted from the distortion of excitation current for electromagnet of the scanner. So, the beam scanning condition, i.e., the relation between the ion species, the beam profile and the scanning width, was extremely limited to make a good uniformity. We have developed a beam scanning simulator to get fluence distributions by calculation and then compared the simulated distributions with the measured ones. It was revealed that the both of them are in good agreement and the beam scanning condition to get good uniformity was led by using this simulator. On the basis of these results, the power supply of scanner was improved. A good uniformity of beam distribution was available. (author)

  15. Uniform approximation is more appropriate for Wilcoxon Rank-Sum Test in gene set analysis.

    Directory of Open Access Journals (Sweden)

    Zhide Fang

    Full Text Available Gene set analysis is widely used to facilitate biological interpretations in the analyses of differential expression from high throughput profiling data. Wilcoxon Rank-Sum (WRS test is one of the commonly used methods in gene set enrichment analysis. It compares the ranks of genes in a gene set against those of genes outside the gene set. This method is easy to implement and it eliminates the dichotomization of genes into significant and non-significant in a competitive hypothesis testing. Due to the large number of genes being examined, it is impractical to calculate the exact null distribution for the WRS test. Therefore, the normal distribution is commonly used as an approximation. However, as we demonstrate in this paper, the normal approximation is problematic when a gene set with relative small number of genes is tested against the large number of genes in the complementary set. In this situation, a uniform approximation is substantially more powerful, more accurate, and less intensive in computation. We demonstrate the advantage of the uniform approximations in Gene Ontology (GO term analysis using simulations and real data sets.

  16. Automated simultaneous assembly of multi-stage testing for the uniform CPA examination

    NARCIS (Netherlands)

    Breithaupt, Krista; Ariel, A.; Veldkamp, Bernard P.

    2004-01-01

    Some solutions used in the assembly of the computerized Uniform Certified Public Accountancy (CPA) licensing examination are offered as practical alternatives for operational programs producing large numbers of forms. The Uniform CPA examination will be offered as an adaptive multi-stage test (MST)

  17. On the Existence of Uniformly Most Powerful Bayesian Tests With Application to Non-Central Chi-Squared Tests

    OpenAIRE

    Nikooienejad, Amir; Johnson, Valen E.

    2018-01-01

    Uniformly most powerful Bayesian tests (UMPBTs) are an objective class of Bayesian hypothesis tests that can be considered the Bayesian counterpart of classical uniformly most powerful tests. Unfortunately, UMPBTs have only been exposed for application in one parameter exponential family models. The purpose of this article is to describe methodology for deriving UMPBTs for a larger class of tests. Specifically, we introduce sufficient conditions for the existence of UMPBTs and propose a unifi...

  18. Development of Drop/Shock Test in Microelectronics and Impact Dynamic Analysis for Uniform Board Response

    Science.gov (United States)

    Kallolimath, Sharan Chandrashekar

    For the past several years, many researchers are constantly developing and improving board level drop test procedures and specifications to quantify the solder joint reliability performance of consumer electronics products. Predictive finite element analysis (FEA) by utilizing simulation software has become widely acceptable verification method which can reduce time and cost of the real-time test process. However, due to testing and metrological limitations it is difficult not only to simulate exact drop condition and capture critical measurement data but also tedious to calibrate the system to improve test methods. Moreover, some of the important ever changing factors such as board flexural rigidity, damping, drop height, and drop orientation results in non-uniform stress/strain distribution throughout the test board. In addition, one of the most challenging tasks is to quantify uniform stress and strain distribution throughout the test board and identify critical failure factors. The major contributions of this work are in the four aspects of the drop test in electronics as following. First of all, an analytical FEA model was developed to study the board natural frequencies and responses of the system with the consideration of dynamic stiffness, damping behavior of the material and effect of impact loading condition. An approach to find the key parameters that affect stress and strain distributions under predominate mode responses was proposed and verified with theoretical solutions. Input-G method was adopted to study board response behavior and cut boundary interpolation methods was used to analyze local model solder joint stresses with the development of global/local FEA model in ANSYS software. Second, no ring phenomenon during the drop test was identified theoretically when the test board was modeled as both discrete system and continuous system. Numerical analysis was then conducted by FEA method for detailed geometry of attached chips with solder

  19. An inverse method for color uniformity in white LED spotlights

    NARCIS (Netherlands)

    Prins, C.R.; Thije Boonkkamp, ten J.H.M.; Tukker, T.W.; IJzerman, W.L.

    2013-01-01

    Color over Angle (CoA) variation in the light output of white phosphor-converted LEDs is a common problem in LED lighting technology. In this article we propose an inverse method to design an optical element that eliminates the color variation for a point light source. The method in this article is

  20. An inverse method for color uniformity in white LED spotlights

    NARCIS (Netherlands)

    Prins, C.R.; Thije Boonkkamp, ten J.H.M.; Tukker, T.W.; IJzerman, W.L.

    2014-01-01

    Color over Angle (CoA) variation in the light output of white phosphor-converted LEDs is a common problem in LED lighting technology. In this article we propose an inverse method to design an optical element that eliminates the color variation for a point light source. The method in this article is

  1. Evaluation of the Discrepancy between the European Pharmacopoeia Test and an Adopted United States Pharmacopoeia Test Regarding the Weight Uniformity of Scored Tablet Halves: Is Harmonization Required?

    Science.gov (United States)

    Zaid, Abdel Naser; Ghoush, Abeer Abu; Al-Ramahi, Rowa'; Are'r, Mohammed

    2012-01-01

    The aim of this study was to evaluate whether there exists any discrepancy between the European Pharmacopoeia (Ph. Eur.) and adopted United States Pharmacopeia (USP) tests concerning the weight uniformity measurements of tablet halves after splitting. The USP method does not contain provisions to evaluate split tablets, so here we adopt their whole tablet weight uniformity method. Twenty-nine different commercial scored tablets (local and imported) were divided. The split units were individually weighed and the relative standard deviation (RSD) for each product was calculated and then evaluated according to both the adopted USP and the Ph. Eur. tests of weight uniformity. Twenty out of the 29 products tested failed the USP test, while 14 of them failed the Ph. Eur. test. Nine products passed both the USP and Ph. Eur. tests. Six products passed the Ph. Eur. test but failed the USP test, with all of these products having an RSD greater than 6%. The correlation coefficient between the weight and content of split halves for three randomly selected products-corotenol 100 mg, corotenol 50 mg, and lorazepam 2.5 mg-was found to be 0.986, 0.998, and 0.72, respectively. A clear difference can be seen between outcomes obtained by the two compendial tablet splitting methods with regard to weight uniformity. Results from the USP test showed that tighter measures are needed to pass the test. Our results argue that the Ph. Eur. should revise the existing weight uniformity test on scored tablets to include the RSD parameter in it. The USP should include this adopted test as a specific test for scored tablet halves, not just whole tablets. Manufacturers in some cases will need to improve the quality of the produced scored tablets in order to pass the USP test, especially those with low therapeutic indices. Finally, harmonization between the pharmacopoeias regarding the weight uniformity testing of split tablets is warranted. The aim of this study was to evaluate whether there

  2. Volume Equalization Method for Land Grading Design: Uniform ...

    African Journals Online (AJOL)

    muğla üniversitesi

    2011-05-23

    May 23, 2011 ... *Corresponding author. E-mail: ... Land grading has been in practice for a long time, but land-grading ... method was based on least-squares theory and he showed its ... Srinisava (1996) developed a nonlinear optimization.

  3. Complementary variational principle method applied to thermal conductivities of a plasma in a uniform magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Sehgal, A K; Gupta, S C [Punjabi Univ., Patiala (India). Dept. of Physics

    1982-12-14

    The complementary variational principles method (CVP) is applied to the thermal conductivities of a plasma in a uniform magnetic field. The results of computations show that the CVP derived results are very useful.

  4. High-uniformity centimeter-wide Si etching method for MEMS devices with large opening elements

    Science.gov (United States)

    Okamoto, Yuki; Tohyama, Yukiya; Inagaki, Shunsuke; Takiguchi, Mikio; Ono, Tomoki; Lebrasseur, Eric; Mita, Yoshio

    2018-04-01

    We propose a compensated mesh pattern filling method to achieve highly uniform wafer depth etching (over hundreds of microns) with a large-area opening (over centimeter). The mesh opening diameter is gradually changed between the center and the edge of a large etching area. Using such a design, the etching depth distribution depending on sidewall distance (known as the local loading effect) inversely compensates for the over-centimeter-scale etching depth distribution, known as the global or within-die(chip)-scale loading effect. Only a single DRIE with test structure patterns provides a micro-electromechanical systems (MEMS) designer with the etched depth dependence on the mesh opening size as well as on the distance from the chip edge, and the designer only has to set the opening size so as to obtain a uniform etching depth over the entire chip. This method is useful when process optimization cannot be performed, such as in the cases of using standard conditions for a foundry service and of short turn-around-time prototyping. To demonstrate, a large MEMS mirror that needed over 1 cm2 of backside etching was successfully fabricated using as-is-provided DRIE conditions.

  5. Acceptability of impregnated school uniforms for dengue control in Thailand: a mixed methods approach.

    Science.gov (United States)

    Murray, Natasha; Jansarikij, Suphachai; Olanratmanee, Phanthip; Maskhao, Pongsri; Souares, Aurélia; Wilder-Smith, Annelies; Kittayapong, Pattamaporn; Louis, Valérie R

    2014-01-01

    As current dengue control strategies have been shown to be largely ineffective in reducing dengue in school-aged children, novel approaches towards dengue control need to be studied. Insecticide-impregnated school uniforms represent an innovative approach with the theoretical potential to reduce dengue infections in school children. This study took place in the context of a randomised control trial (RCT) to test the effectiveness of permethrin-impregnated school uniforms (ISUs) for dengue prevention in Chachoengsao Province, Thailand. The objective was to assess the acceptability of ISUs among parents, teachers, and principals of school children involved in the trial. Quantitative and qualitative tools were used in a mixed methods approach. Class-clustered randomised samples of school children enrolled in the RCT were selected and their parents completed 321 self-administered questionnaires. Descriptive statistics and logistic regression were used to analyse the quantitative data. Focus group discussions and individual semi-structured interviews were conducted with parents, teachers, and principals. Qualitative data analysis involved content analysis with coding and thematic development. The knowledge and experience of dengue was substantial. The acceptability of ISUs was high. Parents (87.3%; 95% CI 82.9-90.8) would allow their child to wear an ISU and 59.9% (95% CI 53.7-65.9) of parents would incur additional costs for an ISU over a normal uniform. This was significantly associated with the total monthly income of a household and the educational level of the respondent. Parents (62.5%; 95% CI 56.6-68.1) indicated they would be willing to recommend ISUs to other parents. Acceptability of the novel tool of ISUs was high as defined by the lack of concern along with the willingness to pay and recommend. Considering issues of effectiveness and scalability, assessing acceptability of ISUs over time is recommended.

  6. Acceptability of impregnated school uniforms for dengue control in Thailand: a mixed methods approach

    Directory of Open Access Journals (Sweden)

    Natasha Murray

    2014-09-01

    Full Text Available Background: As current dengue control strategies have been shown to be largely ineffective in reducing dengue in school-aged children, novel approaches towards dengue control need to be studied. Insecticide-impregnated school uniforms represent an innovative approach with the theoretical potential to reduce dengue infections in school children. Objectives: This study took place in the context of a randomised control trial (RCT to test the effectiveness of permethrin-impregnated school uniforms (ISUs for dengue prevention in Chachoengsao Province, Thailand. The objective was to assess the acceptability of ISUs among parents, teachers, and principals of school children involved in the trial. Methodology: Quantitative and qualitative tools were used in a mixed methods approach. Class-clustered randomised samples of school children enrolled in the RCT were selected and their parents completed 321 self-administered questionnaires. Descriptive statistics and logistic regression were used to analyse the quantitative data. Focus group discussions and individual semi-structured interviews were conducted with parents, teachers, and principals. Qualitative data analysis involved content analysis with coding and thematic development. Results: The knowledge and experience of dengue was substantial. The acceptability of ISUs was high. Parents (87.3%; 95% CI 82.9–90.8 would allow their child to wear an ISU and 59.9% (95% CI 53.7–65.9 of parents would incur additional costs for an ISU over a normal uniform. This was significantly associated with the total monthly income of a household and the educational level of the respondent. Parents (62.5%; 95% CI 56.6–68.1 indicated they would be willing to recommend ISUs to other parents. Conclusions: Acceptability of the novel tool of ISUs was high as defined by the lack of concern along with the willingness to pay and recommend. Considering issues of effectiveness and scalability, assessing acceptability of ISUs

  7. Analytical examination of a spiral beam scanning method for uniform irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Mitsuhiro; Okumura, Susumu; Arakawa, Kazuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    A new circular beam scanning method for uniform irradiation of high-energy, intense ion beams over a large area has been developed. A sweeping speed and a trajectory density in a radial direction are kept constant to obtain uniform fluence distribution. A radial position of a beam spot on a target and an angular frequency of the circular motion are expressed by an irrational function of time. The beam is swept continuously, and a beam trajectory becomes spiral. More than 90 % uniformity of the fluence distribution can been achieved over a large area. (author)

  8. Uniform Foam Crush Testing for Multi-Mission Earth Entry Vehicle Impact Attenuation

    Science.gov (United States)

    Patterson, Byron W.; Glaab, Louis J.

    2012-01-01

    Multi-Mission Earth Entry Vehicles (MMEEVs) are blunt-body vehicles designed with the purpose of transporting payloads from outer space to the surface of the Earth. To achieve high-reliability and minimum weight, MMEEVs avoid use of limited-reliability systems, such as parachutes and retro-rockets, instead using built-in impact attenuators to absorb energy remaining at impact to meet landing loads requirements. The Multi-Mission Systems Analysis for Planetary Entry (M-SAPE) parametric design tool is used to facilitate the design of MMEEVs and develop the trade space. Testing was conducted to characterize the material properties of several candidate impact foam attenuators to enhance M-SAPE analysis. In the current effort, four different Rohacell foams are tested at three different, uniform, strain rates (approximately 0.17, approximately 100, approximately 13,600%/s). The primary data analysis method uses a global data smoothing technique in the frequency domain to remove noise and system natural frequencies. The results from the data indicate that the filter and smoothing technique are successful in identifying the foam crush event and removing aberrations. The effect of strain rate increases with increasing foam density. The 71-WF-HT foam may support Mars Sample Return requirements. Several recommendations to improve the drop tower test technique are identified.

  9. Radiation flaw detector for testing non-uniform surface bodies of revolution

    International Nuclear Information System (INIS)

    Valevich, M.I.

    1984-01-01

    Radiation flaw detector for testing bodies of revolution with non-uniform surface, welded joints, etc., based on spatial filtration and differentiation of ionizing radiation flux has been described. The calculation of the most important unit of flaw detector - integrators - is made. Experimental studies of the sensitivity have shown, that the radiation flaw detector can be used for rapid testing of products with the sensitivity comparable with the sensitivity of radiographic testing of steel

  10. Computational methods and modeling. 1. Sampling a Position Uniformly in a Trilinear Hexahedral Volume

    International Nuclear Information System (INIS)

    Urbatsch, Todd J.; Evans, Thomas M.; Hughes, H. Grady

    2001-01-01

    Monte Carlo particle transport plays an important role in some multi-physics simulations. These simulations, which may additionally involve deterministic calculations, typically use a hexahedral or tetrahedral mesh. Trilinear hexahedrons are attractive for physics calculations because faces between cells are uniquely defined, distance-to-boundary calculations are deterministic, and hexahedral meshes tend to require fewer cells than tetrahedral meshes. We discuss one aspect of Monte Carlo transport: sampling a position in a tri-linear hexahedron, which is made up of eight control points, or nodes, and six bilinear faces, where each face is defined by four non-coplanar nodes in three-dimensional Cartesian space. We derive, code, and verify the exact sampling method and propose an approximation to it. Our proposed approximate method uses about one-third the memory and can be twice as fast as the exact sampling method, but we find that its inaccuracy limits its use to well-behaved hexahedrons. Daunted by the expense of the exact method, we propose an alternate approximate sampling method. First, calculate beforehand an approximate volume for each corner of the hexahedron by taking one-eighth of the volume of an imaginary parallelepiped defined by the corner node and the three nodes to which it is directly connected. For the sampling, assume separability in the parameters, and sample each parameter, in turn, from a linear pdf defined by the sum of the four corner volumes at each limit (-1 and 1) of the parameter. This method ignores the quadratic portion of the pdf, but it requires less storage, has simpler sampling, and needs no extra, on-the-fly calculations. We simplify verification by designing tests that consist of one or more cells that entirely fill a unit cube. Uniformly sampling complicated cells that fill a unit cube will result in uniformly sampling the unit cube. Unit cubes are easily analyzed. The first problem has four wedges (or tents, or A frames) whose

  11. Comparisons of uniform and discrete source distributions for use in bioassay laboratory performance testing

    International Nuclear Information System (INIS)

    Scherpelz, R.I.; MacLellan, J.A.

    1987-09-01

    The Pacific Northwest Laboratory (PNL) is sending a torso phantom with radioactive material uniformly distributed in the lungs to in vivo bioassay laboratories for analysis. Although the radionuclides ultimately chosen for the studies had relatively long half-lives, future accreditation testing will require repeated tests with short half-life test nuclides. Computer modeling was used to simulate the major components of the phantom. Radiation transport calculations were then performed using the computer models to calculate dose rates either 15 cm from the chest or at its surface. For 144 Ce and 60 Co, three configurations were used for the lung comparison tests. Calculations show that, for most detector positions, a single plug containing 40 K located in the back of the heart provides a good approximation to a uniform distribution of 40 K. The approximation would lead, however, to a positive bias for the detector reading if the detector were located at the chest surface near the center. Loading the 40 K in a uniform layer inside the chest wall is not a good approximation of the uniform distribution in the lungs, because most of the radionuclides would be situated close to the detector location and the only shielding would be the thickness of the chest wall. The calculated dose rates for 60 Co and 144 Ce were similar at all calculated reference points. 3 refs., 5 figs., 10 tabs

  12. The Role of Cohesive Particle Interactions on Solids Uniformity and Mobilization During Jet Mixing: Testing Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Gauglitz, Phillip A.; Wells, Beric E.; Bamberger, Judith A.; Fort, James A.; Chun, Jaehun; Jenks, Jeromy WJ

    2010-04-01

    Radioactive waste that is currently stored in large underground tanks at the Hanford Site will be staged in selected double-shell tanks (DSTs) and then transferred to the Waste Treatment and Immobilization Plant (WTP). Before being transferred, the waste will be mixed, sampled, and characterized to determine if the waste composition and meets the waste feed specifications. Washington River Protection Solutions is conducting a Tank Mixing and Sampling Demonstration Program to determine the mixing effectiveness of the current baseline mixing system that uses two jet mixer pumps and the adequacy of the planned sampling method. The overall purpose of the demonstration program is to mitigate the technical risk associated with the mixing and sampling systems meeting the feed certification requirements for transferring waste to the WTP.The purpose of this report is to analyze existing data and evaluate whether scaled mixing tests with cohesive simulants are needed to meet the overall objectives of the small-scale mixing demonstration program. This evaluation will focus on estimating the role of cohesive particle interactions on various physical phenomena that occur in parts of the mixing process. A specific focus of the evaluation will be on the uniformity of suspended solids in the mixed region. Based on the evaluation presented in this report and the absence of definitive studies, the recommendation is to conduct scaled mixing tests with cohesive particles and augment the initial testing with non-cohesive particles. In addition, planning for the quantitative tests would benefit from having test results from some scoping experiments that would provide results on the general behavior when cohesive inter-particle forces are important.

  13. Calibration of EBT2 film by the PDD method with scanner non-uniformity correction.

    Science.gov (United States)

    Chang, Liyun; Chui, Chen-Shou; Ding, Hueisch-Jy; Hwang, Ing-Ming; Ho, Sheng-Yow

    2012-09-21

    exposed to 60° physical wedge fields and the compositive fields, and their relative dose profiles were compared with those from the water phantom measurement. The fitting uncertainty was less than 0.5% due to the many calibration points, and the overall calibration uncertainty was within 3% for doses above 50 cGy, when the average of four films were used for the calibration. According to our study, the non-uniformity calibration factor was found to be independent of the given dose for the EBT2 film and the relative dose differences between the profiles measured by the film and the Profiler were within 1.5% after applying the non-uniformity correction. For the verification tests, the relative dose differences between the measurements by films and in the water phantom, when the average of three films were used, were generally within 3% for the 60° wedge fields and compositive fields, respectively. In conclusion, our method is convenient, time-saving and cost-effective, since no film cutting is needed and only two films with two exposures are needed.

  14. Calibration of EBT2 film by the PDD method with scanner non-uniformity correction

    International Nuclear Information System (INIS)

    Chang Liyun; Ding, Hueisch-Jy; Chui, Chen-Shou; Hwang, Ing-Ming; Ho, Sheng-Yow

    2012-01-01

    exposed to 60° physical wedge fields and the compositive fields, and their relative dose profiles were compared with those from the water phantom measurement. The fitting uncertainty was less than 0.5% due to the many calibration points, and the overall calibration uncertainty was within 3% for doses above 50 cGy, when the average of four films were used for the calibration. According to our study, the non-uniformity calibration factor was found to be independent of the given dose for the EBT2 film and the relative dose differences between the profiles measured by the film and the Profiler were within 1.5% after applying the non-uniformity correction. For the verification tests, the relative dose differences between the measurements by films and in the water phantom, when the average of three films were used, were generally within 3% for the 60° wedge fields and compositive fields, respectively. In conclusion, our method is convenient, time-saving and cost-effective, since no film cutting is needed and only two films with two exposures are needed. (paper)

  15. Uniform distribution and quasi-Monte Carlo methods discrepancy, integration and applications

    CERN Document Server

    Kritzer, Peter; Pillichshammer, Friedrich; Winterhof, Arne

    2014-01-01

    The survey articles in this book focus on number theoretic point constructions, uniform distribution theory, and quasi-Monte Carlo methods. As deterministic versions of the Monte Carlo method, quasi-Monte Carlo rules enjoy increasing popularity, with many fruitful applications in mathematical practice, as for example in finance, computer graphics, and biology.

  16. Method to incorporate anisotropic semiconductor nanocrystals of all shapes in an ultrathin and uniform silica shell

    NARCIS (Netherlands)

    Hutter, Eline M.; Pietra, Francesca; Moes, Relinde; Mitoraj, Dariusz; Meeldijk, Johannes D.; De Mello Donegá, Celso; Vanmaekelbergh, Daniël

    2014-01-01

    In this work, we present a method for the incorporation of anisotropic colloidal nanocrystals of many different shapes in silica in a highly controlled way. This method yields a uniform silica shell, with thickness tunable from 3 to 17 nm. The silica shell perfectly adapts to the shape of the

  17. On the Bahadur-efficient testing of uniformity by means of entropy

    Czech Academy of Sciences Publication Activity Database

    Harremoes, P.; Vajda, Igor

    2008-01-01

    Roč. 54, č. 1 (2008), s. 321-331 ISSN 0018-9448 R&D Projects: GA MŠk(CZ) 1M0572; GA ČR(CZ) GA102/07/1131 Institutional research plan: CEZ:AV0Z10750506 Keywords : Bahadur-efficient testing * power divergence tests * power entropy tests Subject RIV: BD - Theory of Information Impact factor: 3.793, year: 2008 http://library.utia.cas.cz/separaty/2010/SI/vajda-on the bahadur-efficient testing of uniformity by means of entropy.pdf

  18. Design and testing of a uniformly solar energy TIR-R concentration lenses for HCPV systems.

    Science.gov (United States)

    Shen, S C; Chang, S J; Yeh, C Y; Teng, P C

    2013-11-04

    In this paper, total internal reflection-refraction (TIR-R) concentration (U-TIR-R-C) lens module were designed for uniformity using the energy configuration method to eliminate hot spots on the surface of solar cell and increase conversion efficiency. The design of most current solar concentrators emphasizes the high-power concentration of solar energy, however neglects the conversion inefficiency resulting from hot spots generated by uneven distributions of solar energy concentrated on solar cells. The energy configuration method proposed in this study employs the concept of ray tracing to uniformly distribute solar energy to solar cells through a U-TIR-R-C lens module. The U-TIR-R-C lens module adopted in this study possessed a 76-mm diameter, a 41-mm thickness, concentration ratio of 1134 Suns, 82.6% optical efficiency, and 94.7% uniformity. The experiments demonstrated that the U-TIR-R-C lens module reduced the core temperature of the solar cell from 108 °C to 69 °C and the overall temperature difference from 45 °C to 10 °C, and effectively relative increased the conversion efficiency by approximately 3.8%. Therefore, the U-TIR-R-C lens module designed can effectively concentrate a large area of sunlight onto a small solar cell, and the concentrated solar energy can be evenly distributed in the solar cell to achieve uniform irradiance and effectively eliminate hot spots.

  19. A progressively reduced pretension method to fabricate Bradbury-Nielsen gates with uniform tension

    International Nuclear Information System (INIS)

    Ni, Kai; Guo, Jingran; Yu, Zhou; Cao, Like; Yu, Quan; Qian, Xiang; Wang, Xiaohao

    2015-01-01

    A Bradbury-Nielsen gate (BNG) is often used to modulate ion beams. It consists of two interleaved and electrically isolated sets of wires with uniform tension, which ideally keep parallel, equidistant, and coplanar over a wide temperature range, making the BNG reliable and robust. We have previously analyzed the non-uniformity problem of wire tensions with sequentially winding method and developed a template-based transfer method to solve this problem. In this paper, we introduced a progressively reduced pretension method, which allows directly and sequentially fixing wires onto the substrate without using a template. Theoretical analysis shows that by applying proper pretension to each wire when fixing it, the final wire tensions of all wires can be uniform. The algorithm and flowchart to calculate the pretension sequence are given, and the fabrication process is introduced in detail. Pretensions are generated by weight combination with a weaving device. A BNG with stainless steel wire and a printed circuit board substrate is constructed with this method. The non-uniformity of the final wire tensions is less than 2.5% in theory. The BNG is successfully employed in our ion mobility spectrometer, and the measured resolution is 33.5 at a gate opening time of 350 μs. Compared to the template-based method, this method is simpler, faster, and more flexible with comparable production quality when manufacturing BNGs with different configurations

  20. On the Bahadur-efficient testing of uniformity by means of entropy

    Czech Academy of Sciences Publication Activity Database

    Vajda, Igor; Harremoës, P.

    2008-01-01

    Roč. 54, 1/2 (2008), s. 321-331 ISSN 0018-9448 R&D Projects: GA MŠk(CZ) 1M0572; GA ČR(CZ) GA102/07/1131 Institutional research plan: CEZ:AV0Z10750506 Keywords : Bahadur efficiency * entropy * goodness-of-fit * power divergences * uniformity testing Subject RIV: BD - Theory of Information Impact factor: 3.793, year: 2008

  1. Probabilistic uniformities of uniform spaces

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Lopez, J.; Romaguera, S.; Sanchis, M.

    2017-07-01

    The theory of metric spaces in the fuzzy context has shown to be an interesting area of study not only from a theoretical point of view but also for its applications. Nevertheless, it is usual to consider these spaces as classical topological or uniform spaces and there are not too many results about constructing fuzzy topological structures starting from a fuzzy metric. Maybe, H/{sup o}hle was the first to show how to construct a probabilistic uniformity and a Lowen uniformity from a probabilistic pseudometric /cite{Hohle78,Hohle82a}. His method can be directly translated to the context of fuzzy metrics and allows to characterize the categories of probabilistic uniform spaces or Lowen uniform spaces by means of certain families of fuzzy pseudometrics /cite{RL}. On the other hand, other different fuzzy uniformities can be constructed in a fuzzy metric space: a Hutton $[0,1]$-quasi-uniformity /cite{GGPV06}; a fuzzifiying uniformity /cite{YueShi10}, etc. The paper /cite{GGRLRo} gives a study of several methods of endowing a fuzzy pseudometric space with a probabilistic uniformity and a Hutton $[0,1]$-quasi-uniformity. In 2010, J. Guti/'errez Garc/'{/i}a, S. Romaguera and M. Sanchis /cite{GGRoSanchis10} proved that the category of uniform spaces is isomorphic to a category formed by sets endowed with a fuzzy uniform structure, i. e. a family of fuzzy pseudometrics satisfying certain conditions. We will show here that, by means of this isomorphism, we can obtain several methods to endow a uniform space with a probabilistic uniformity. Furthermore, these constructions allow to obtain a factorization of some functors introduced in /cite{GGRoSanchis10}. (Author)

  2. Semiconductor testing method

    International Nuclear Information System (INIS)

    Brown, Stephen.

    1992-01-01

    In a method of avoiding use of nuclear radiation, eg gamma rays, X-rays, electron beams, for testing semiconductor components for resistance to hard radiation, which hard radiation causes data corruption in some memory devices and 'latch-up' in others, similar fault effects can be achieved using a xenon or other 'light' flash gun even though the penetration of light is significantly less than that of gamma rays. The method involves treating a device with gamma radiation, measuring a particular fault current at the onset of a fault event, repeating the test with light to confirm the occurrence of the fault event at the same measured fault current, and using the fault current value as a reference for future tests using light on similar devices. (author)

  3. Materials and test methods

    International Nuclear Information System (INIS)

    Kase, M.B.

    1985-01-01

    The objective of this study was to provide, in cooperation with ORNL and LANL, specimens required for studies to develop organic insulators having the cryogenic neutron irradiation resistance required for MFE systems utilizing superconducting magnetic confinement. To develop test methods and analytical procedures for assessing radiation damage. To stimulate and participate in international cooperation directed toward accomplishing these objectives. The system for producing uniaxially reinforced, 3-4 mm (0.125 in) diameter rod specimens has been refined and validated by production of excellent quality specimens using liquid-mix epoxy resin systems. The methodology is undergoing further modification to permit use of hot-melt epoxy and polyimide resin systems as will be required for the experimental program to be conducted in the NLTNIF reactor at ORNL. Preliminary studies indicate that short beam and torsional shear test methods will be useful in evaluating radiation degradation. Development of these and other applicable test methods are continuing. A cooperative program established with laboratories in Japan and in England has resulted in the production and testing of specimens having an identical configuration

  4. A method to measure the mean thickness and non-uniformity of non-uniform thin film by alpha-ray thickness gauge

    International Nuclear Information System (INIS)

    Miyahara, Hiroshi; Yoshida, Makoto; Watanabe, Tamaki

    1977-01-01

    The α-ray thickness gauge is used to measure non-destructively the thicknesses of thin films, and up to the present day, a thin film with uniform thickness is only taken up as the object of α-ray thickness gauge. When the thickness is determined from the displacement between the absorption curves in the presence and absence of thin film, the absorption curve must be displaced in parallel. When many uniform particles were dispersed as sample, the shape of the absorption curve was calculated as the sum of many absorption curves corresponding to the thin films with different thicknesses. By the comparison of the calculated and measured absorption curves, the number of particles, or the mean superficial density can be determined. This means the extension of thickness measurement from uniform to non-uniform films. Furthermore, these particle models being applied to non-uniform thin film, the possibility of measuring the mean thickness and non-uniformity was discussed. As the result, if the maximum difference of the thickness was more than 0.2 mg/cm 2 , the nonuniformity was considered to distinguish by the usual equipment. In this paper, an α-ray thickness gauge using the absorption curve method was treated, but one can apply this easily to an α-ray thickness gauge using α-ray energy spectra before and after the penetration of thin film. (auth.)

  5. A method for the preparation of very thin and uniform α-radioactive sources

    International Nuclear Information System (INIS)

    Becerril-Vilchis, A.; Cortes, A.; Dayras, F.; Sanoit, J. de

    1996-01-01

    The method is based on the electrodeposition of α-emitters as hydroxides on stainless steel cathodes rotating at constant angular velocity. A new electrochemical cell, which has been described elsewhere, was designed. This design takes into account the hydrodynamic behaviour of the rotating disc electrode. Electrochemical and physicochemical studies allowed us to predict the best conditions for each α-emitter, in order to obtain very thin and uniform deposits with a minimal current density value. These included determining the dependence of the deposition yield and uniformity on the cathode rotation speed, solution pH, deposition current density and deposition time. Controlling the optimum values of hydrodynamic, electrochemical and physicochemical process conditions then gives reproducible deposition uniformity and yields. The thickness and uniformity of the α-sources were characterised by high resolution alpha spectroscopy with PIPS detectors. These sources are specially suitable for spectroscopic, α-particle emission probability and isotopic ratio studies. Using this method values ≤10 keV for the energy resolution and 100 to 1 for the peak to valley ratio have been obtained. (orig.)

  6. New reversing freeform lens design method for LED uniform illumination with extended source and near field

    Science.gov (United States)

    Zhao, Zhili; Zhang, Honghai; Zheng, Huai; Liu, Sheng

    2018-03-01

    In light-emitting diode (LED) array illumination (e.g. LED backlighting), obtainment of high uniformity in the harsh condition of the large distance height ratio (DHR), extended source and near field is a key as well as challenging issue. In this study, we present a new reversing freeform lens design algorithm based on the illuminance distribution function (IDF) instead of the traditional light intensity distribution, which allows uniform LED illumination in the above mentioned harsh conditions. IDF of freeform lens can be obtained by the proposed mathematical method, considering the effects of large DHR, extended source and near field target at the same time. In order to prove the claims, a slim direct-lit LED backlighting with DHR equal to 4 is designed. In comparison with the traditional lenses, illuminance uniformity of LED backlighting with the new lens increases significantly from 0.45 to 0.84, and CV(RMSE) decreases dramatically from 0.24 to 0.03 in the harsh condition. Meanwhile, luminance uniformity of LED backlighting with the new lens is obtained as high as 0.92 at the condition of extended source and near field. This new method provides a practical and effective way to solve the problem of large DHR, extended source and near field for LED array illumination.

  7. Silver Nanowire Transparent Conductive Films with High Uniformity Fabricated via a Dynamic Heating Method.

    Science.gov (United States)

    Jia, Yonggao; Chen, Chao; Jia, Dan; Li, Shuxin; Ji, Shulin; Ye, Changhui

    2016-04-20

    The uniformity of the sheet resistance of transparent conductive films is one of the most important quality factors for touch panel applications. However, the uniformity of silver nanowire transparent conductive films is far inferior to that of indium-doped tin oxide (ITO). Herein, we report a dynamic heating method using infrared light to achieve silver nanowire transparent conductive films with high uniformity. This method can overcome the coffee ring effect during the drying process and suppress the aggregation of silver nanowires in the film. A nonuniformity factor of the sheet resistance of the as-prepared silver nanowire transparent conductive films could be as low as 6.7% at an average sheet resistance of 35 Ω/sq and a light transmittance of 95% (at 550 nm), comparable to that of high-quality ITO film in the market. In addition, a mechanical study shows that the sheet resistance of the films has little change after 5000 bending cycles, and the film could be used in touch panels for human-machine interactive input. The highly uniform and mechanically stable silver nanowire transparent conductive films meet the requirement for many significant applications and could play a key role in the display market in a near future.

  8. Construction of a test stand for the measurement of the light output uniformity of CALIFA crystals

    Energy Technology Data Exchange (ETDEWEB)

    Susenburger, Markus; Ignatov, Alexander; Kroell, Thorsten [Technische Universitaet Darmstadt, Darmstadt (Germany)

    2016-07-01

    Currently, the Facility for Antiproton and Ion Research (FAIR) at GSI in Darmstadt is under construction. One experiment at GSI and FAIR is called Reactions with Relativistic Radioactive Beams (R{sup 3}B). A key component of the R{sup 3}B is the CALorimeter for In Flight detection of γ-rays and light charged pArticles (CALIFA), which will surround the R{sup 3}B target chamber and will be capable of the detection of γ-rays in a wide energy range from 100 keV to 30 MeV as well as of light charged particles. CALIFA is built out of two parts, the so called CALIFA barrel and CALIFA endcap. The barrel consists of 1952 CsI(Tl) detector crystals which have to fulfill several specifications. One of these specifications is the uniformity of the light output. Depending on the location of the deposited energy, the crystal's light output varies due to optical focusing effects. This behavior can be manipulated by lapping the crystal's surface. The aim of this work is the development of a test stand which will check if the crystals match the requirements according to the light output uniformity. Because of the large number of crystals needed to be tested, the stand automates the test procedure, which guarantees comparable test measurement for all crystals. The development and construction of this stand is reported.

  9. A method for real time detecting of non-uniform magnetic field

    Science.gov (United States)

    Marusenkov, Andriy

    2015-04-01

    The principle of measuring magnetic signatures for observing diverse objects is widely used in Near Surface work (unexploded ordnance (UXO); engineering & environmental; archaeology) and security and vehicle detection systems as well. As a rule, the magnitude of the signals to be measured is much lower than that of the quasi-uniform Earth magnetic field. Usually magnetometers for these purposes contain two or more spatially separated sensors to estimate the full tensor gradient of the magnetic field or, more frequently, only partial gradient components. The both types (scalar and vector) of magnetic sensors could be used. The identity of the scale factors and proper alignment of the sensitivity axes of the vector sensors are very important for deep suppression of the ambient field and detection of weak target signals. As a rule, the periodical calibration procedure is used to keep matching sensors' parameters as close as possible. In the present report we propose the technique for detection magnetic anomalies, which is almost insensitive to imperfect matching of the sensors. This method based on the idea that the difference signals between two sensors are considerably different when the instrument is rotated or moved in uniform and non-uniform fields. Due to the misfit of calibration parameters the difference signal observed at the rotation in the uniform field is similar to the total signal - the sum of the signals of both sensors. Zero change of the difference and total signals is expected, if the instrument moves in the uniform field along a straight line. In contrast, the same move in the non-uniform field produces some response of each of the sensors. In case one measures dB/dx and moves along x direction, the sensors signals is shifted in time with the lag proportional to the distance between sensors and the speed of move. It means that the difference signal looks like derivative of the total signal at move in the non-uniform field. So, using quite simple

  10. Uniform irradiation using rotational-linear scanning method for narrow synchrotron radiation beam

    International Nuclear Information System (INIS)

    Nariyama, N.; Ohnishi, S.; Odano, N.

    2004-01-01

    At SPring-8, photon intensity monitors for synchrotron radiation have been developed. Using these monitors, the responses of radiation detectors and dosimeters to monoenergetic photons can be measured. In most cases, uniform irradiation to the sample is necessary. Here, two scanning methods are proposed. One is an XZ-linear scanning method, which moves the sample simultaneously in both the X and Z direction, that is, in zigzag fashion. The other is a rotational-linear scanning method, which rotates the sample moving in the X direction. To investigate the validity of the two methods, thermoluminescent dosimeters were irradiated with a broad synchrotron-radiation beam, and the readings from the two methods were compared with that of the dosimeters fixed in the beam. The results for both scanning methods virtually agreed with that of the fixed method. The advantages of the rotational-linear scanning method are that low- and medium-dose irradiation is possible, uniformity is excellent and the load to the scanning equipment is light: hence, this method is superior to the XZ-linear scanning method for most applications. (author)

  11. A New Method for Determining Permethrin Level on Military Uniform Fabrics

    Science.gov (United States)

    2017-06-01

    new desorption-gas chromatography– mass spectrometry based screening tool for permethrin content in military fabrics was developed. The method allows...SUBJECT TERMS permethrin, Army Combat Uniform, ACU, camouflage, desorption-gas chromatography- mass spectrometry , D-GC-MS 16. SECURITY CLASSIFICATION OF...reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching

  12. Hydra phantom applicability for carrying out tests of field uniformity in gamma cameras

    International Nuclear Information System (INIS)

    Aragao Filho, Geraldo L.; Oliveira, Alex C.H.

    2014-01-01

    Nuclear Medicine is a medical modality that makes use of radioactive material 'in vivo' in humans, making them a temporary radioactive source. The radiation emitted by the patient's body is detected by a specific equipment, called a gamma camera, creates an image showing the spatial and temporal biodistribution of radioactive material administered to the patient. Therefore, it's of fundamental importance a number of specific measures to make sure that procedure be satisfactory, called quality control. To Nuclear Medicine, quality control of gamma camera has the purpose of ensuring accurate scintillographic imaging, truthful and reliable for the diagnosis, guaranteeing visibility and clarity of details of structures, and also to determine the frequency and the need for preventive maintenance of equipment. To ensure the quality control of the gamma camera it's necessary to use some simulators, called phantom, used in Nuclear Medicine to evaluate system performance, system calibration and simulation of injuries. The goal of this study was to validate a new simulator for nuclear medicine, the Hydra phantom. The phantom was initially built for construction of calibration curves used in radiotherapy planning and quality control in CT. It has similar characteristics to specific phantoms in nuclear medicine, containing inserts and water area. Those inserts are regionally sourced materials, many of them are already used in the literature and based on information about density and interaction of radiation with matter. To verify its efficiency in quality control in Nuclear Medicine, was performed a test for uniformity field, one of the main tests performed daily, so we can verify the ability of the gamma camera to reproduce a uniform distribution of the administered activity in the phantom, been analysed qualitatively, through the image, and quantitatively, through values established for Central Field Of View (CFOV) and Useful Field Of View (UFOV). Also, was evaluated their

  13. Dissolution Behavior and Content Uniformity of An Improved Tablet Formulation Assayed by Spectrofluorometric and RIA Methods

    Directory of Open Access Journals (Sweden)

    Morteza Rafiee-Tehrani

    1990-06-01

    Full Text Available Digoxin 0.25 mg tablets were manufactured by pregranulation of lactose-fcorn starch with 10% corn starch paste and deposition of solvent on pregranules to make digoxin granules. In the preparation of tablet A, granules of lactose-corn Starch was uniformly moistened with a 5% chloroform-ethanol solution (2:lv/vof digoxin by a simple blending. Tablet B was produced by spray granulation system on which the solvent was sprayed on the granules of lactose-corn starch by utilization of a laboratory size fluidized bed drier (Uniglatt . The content uniformity and dissolution of both tablets were determined by the spectrofluorometric and radio¬immunoassay (RIA method modified for the assay of tablet solutious. One available commercially brand of digoxin tablet (C was included in dissolution study for comparison. For the spectrofluorometric method the technique is based on the fluor-ometric measurenent of the dehydration product of the cardiotonic steroid resulting from its reaction with hydrogen peroxide in concentrated hydrochloric acid. For the RIA method, the filtrate was diluted to theoretical concentration of 2.5 ng/ml."nAliquots of this dilution were then assayed for digoxin content using a commercial digoxin125 I RIA kit. Results from both assay methods were extrapolated to the total tablet content and compared with the labeled amount of 20 individual tablets. All tablet assay results were within the USP standards for the content uniformity and"ndissolution of individual. The individual tablet deviations from labeled amount by RIA method were smaller when compared with the spectrofluorometric method.There was no significant difference between the release of digoxin from three products, and thus it is suggested that the Procedure B could be easily applied for manufacturing"nof digoxin tablets in industrial scales.It was also concluded that,the RIA method could be used for the digoxin tablet determination.

  14. Incorporation of Collision Probability Method in STREAM to Consider Non-uniform Material Composition in Fuel Subregions

    International Nuclear Information System (INIS)

    Choi, Sooyoung; Choe, Jiwon; Lee, Deokjung

    2016-01-01

    STREAM uses a pin-based slowing-down method (PSM) which solves pointwise energy slowing-down problems with sub-divided fuel pellet, and shows a great performance in calculating effective cross-section (XS). Various issues in the conventional resonance treatment methods (i.e., approximations on resonance scattering source, resonance interference effect, and intrapellet self-shielding effect) were successfully resolved by PSM. PSM assumes that a fuel rod has a uniform material composition and temperature even though PSM calculates spatially dependent effective XSs of fuel subregions. When the depletion calculation or thermal/hydraulic (T/H) coupling are performed with sub-divided material meshes, each subregion has its own material condition depending on position. It was reported that the treatment of distributed temperature is important to calculate an accurate fuel temperature coefficient (FTC). In order to avoid the approximation in PSM, the collision probability method (CPM) has been incorporated as a calculation option. The resonance treatment method, PSM, used in the transport code STREAM has been enhanced to accurately consider a non-uniform material condition. The method incorporates CPM in computing collision probability of isolated fuel pin. From numerical tests with pin-cell problems, STREAM with the method showed very accurate multiplication factor and FTC results less than 83 pcm and 1.43 % differences from the references, respectively. The original PSM showed larger differences than the proposed method but still has a high accuracy

  15. Incorporation of Collision Probability Method in STREAM to Consider Non-uniform Material Composition in Fuel Subregions

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sooyoung; Choe, Jiwon; Lee, Deokjung [UNIST, Ulsan (Korea, Republic of)

    2016-10-15

    STREAM uses a pin-based slowing-down method (PSM) which solves pointwise energy slowing-down problems with sub-divided fuel pellet, and shows a great performance in calculating effective cross-section (XS). Various issues in the conventional resonance treatment methods (i.e., approximations on resonance scattering source, resonance interference effect, and intrapellet self-shielding effect) were successfully resolved by PSM. PSM assumes that a fuel rod has a uniform material composition and temperature even though PSM calculates spatially dependent effective XSs of fuel subregions. When the depletion calculation or thermal/hydraulic (T/H) coupling are performed with sub-divided material meshes, each subregion has its own material condition depending on position. It was reported that the treatment of distributed temperature is important to calculate an accurate fuel temperature coefficient (FTC). In order to avoid the approximation in PSM, the collision probability method (CPM) has been incorporated as a calculation option. The resonance treatment method, PSM, used in the transport code STREAM has been enhanced to accurately consider a non-uniform material condition. The method incorporates CPM in computing collision probability of isolated fuel pin. From numerical tests with pin-cell problems, STREAM with the method showed very accurate multiplication factor and FTC results less than 83 pcm and 1.43 % differences from the references, respectively. The original PSM showed larger differences than the proposed method but still has a high accuracy.

  16. Facile Synthesis of Long, Straight and Uniform Copper Nanowires via a Solvothermal Method

    Institute of Scientific and Technical Information of China (English)

    Chunfu Lin; Hong Lin; Ning Wang; Xing Zhang; Jun Yang; Jianbo Li; Xiaozhan Yang

    2006-01-01

    Copper nanowires were facilely prepared via a solvothermal method. In this method, cetyltrimethylammonium bromide (CTAB) was used as a soft template, copper nitrate was an inorganic precursor, and absolute ethanol served as a reducing agent as well as a solvent. X-ray diffraction (XRD) and scanning electron microscopy (SEM) were used to characterize the as-prepared copper nanowires. The as-prepared copper nanowires are fairly uniform and long. The majority of them are longer than 100 μm and some even longer than 200 μm. Furthermore, most nanowires are quite straight. In addition,The mechanism of the growth process of copper nanowires was discussed.

  17. A simple method to improve the spatial uniformity of venetian-blind photomultiplier tubes

    International Nuclear Information System (INIS)

    Santos, J.M.F. dos; Veloso, J.F.C.A.; Morgado, R.E.

    1996-01-01

    An improvement in the uniformity of venetian-blind photomultiplier tubes has been achieved by reducing the voltage difference between the first and second dynodes. The method has been applied to a gas proportional scintillation counter (GPSC) instrumented with a venetian-blind photomultiplier (PMT). When exposed to a 20-mm collimated 5.9-keV x-ray beam, an overall improvement in energy resolution for the GPSC/PMT combination from 20% to 11.5% was achieved. An alternative method that reduces the photocathode-to-first-dynode voltage was less effective and resulted in a severe degradation of detector energy resolution

  18. Automatic method detection of artifacts for control of tomographic uniformity on SPECT; Metodo automatico de dteccion de artefactos para el control de la uniformidad tomografica en SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Reynes Llompart, G.; Puchal, R.

    2013-07-01

    The objective of this work is the find an automatic method for the detection and classification of artifacts produced in tomographic uniformity, extracting the characteristics necessary to apply a classification algorithm using pattern recognition techniques. The method has been trained and validated with synthetic images and tested with real images. (Author)

  19. New method for solving inductive electric fields in the non-uniformly conducting ionosphere

    Directory of Open Access Journals (Sweden)

    H. Vanhamäki

    2006-10-01

    Full Text Available We present a new calculation method for solving inductive electric fields in the ionosphere. The time series of the potential part of the ionospheric electric field, together with the Hall and Pedersen conductances serves as the input to this method. The output is the time series of the induced rotational part of the ionospheric electric field. The calculation method works in the time-domain and can be used with non-uniform, time-dependent conductances. In addition, no particular symmetry requirements are imposed on the input potential electric field. The presented method makes use of special non-local vector basis functions called the Cartesian Elementary Current Systems (CECS. This vector basis offers a convenient way of representing curl-free and divergence-free parts of 2-dimensional vector fields and makes it possible to solve the induction problem using simple linear algebra. The new calculation method is validated by comparing it with previously published results for Alfvén wave reflection from a uniformly conducting ionosphere.

  20. New method for solving inductive electric fields in the non-uniformly conducting ionosphere

    Science.gov (United States)

    Vanhamäki, H.; Amm, O.; Viljanen, A.

    2006-10-01

    We present a new calculation method for solving inductive electric fields in the ionosphere. The time series of the potential part of the ionospheric electric field, together with the Hall and Pedersen conductances serves as the input to this method. The output is the time series of the induced rotational part of the ionospheric electric field. The calculation method works in the time-domain and can be used with non-uniform, time-dependent conductances. In addition, no particular symmetry requirements are imposed on the input potential electric field. The presented method makes use of special non-local vector basis functions called the Cartesian Elementary Current Systems (CECS). This vector basis offers a convenient way of representing curl-free and divergence-free parts of 2-dimensional vector fields and makes it possible to solve the induction problem using simple linear algebra. The new calculation method is validated by comparing it with previously published results for Alfvén wave reflection from a uniformly conducting ionosphere.

  1. PARALLEL AND ADAPTIVE UNIFORM-DISTRIBUTED REGISTRATION METHOD FOR CHANG’E-1 LUNAR REMOTE SENSED IMAGERY

    Directory of Open Access Journals (Sweden)

    X. Ning

    2012-08-01

    To resolve the above-mentioned registration difficulties, a parallel and adaptive uniform-distributed registration method for CE-1 lunar remote sensed imagery is proposed in this paper. Based on 6 pairs of randomly selected images, both the standard SIFT algorithm and the parallel and adaptive uniform-distributed registration method were executed, the versatility and effectiveness were assessed. The experimental results indicate that: by applying the parallel and adaptive uniform-distributed registration method, the efficiency of CE-1 lunar remote sensed imagery registration were increased dramatically. Therefore, the proposed method in the paper could acquire uniform-distributed registration results more effectively, the registration difficulties including difficult to obtain results, time-consuming, non-uniform distribution could be successfully solved.

  2. An efficient and general numerical method to compute steady uniform vortices

    Science.gov (United States)

    Luzzatto-Fegiz, Paolo; Williamson, Charles H. K.

    2011-07-01

    Steady uniform vortices are widely used to represent high Reynolds number flows, yet their efficient computation still presents some challenges. Existing Newton iteration methods become inefficient as the vortices develop fine-scale features; in addition, these methods cannot, in general, find solutions with specified Casimir invariants. On the other hand, available relaxation approaches are computationally inexpensive, but can fail to converge to a solution. In this paper, we overcome these limitations by introducing a new discretization, based on an inverse-velocity map, which radically increases the efficiency of Newton iteration methods. In addition, we introduce a procedure to prescribe Casimirs and remove the degeneracies in the steady vorticity equation, thus ensuring convergence for general vortex configurations. We illustrate our methodology by considering several unbounded flows involving one or two vortices. Our method enables the computation, for the first time, of steady vortices that do not exhibit any geometric symmetry. In addition, we discover that, as the limiting vortex state for each flow is approached, each family of solutions traces a clockwise spiral in a bifurcation plot consisting of a velocity-impulse diagram. By the recently introduced "IVI diagram" stability approach [Phys. Rev. Lett. 104 (2010) 044504], each turn of this spiral is associated with a loss of stability for the steady flows. Such spiral structure is suggested to be a universal feature of steady, uniform-vorticity flows.

  3. The history, development and application of a uniformly applied load wide plate testing machine

    International Nuclear Information System (INIS)

    Quirk, A.; Bevitt, E.

    1989-01-01

    The paper describes early attempts to use a rigid end wide plate testing machine to investigate the behaviour of centre cracked flat plates. Confusing and inconsistent results arising from the above tests lead to a detailed investigation of the loading characteristics of rigid end machines in general and the difficulties which can arise in the interpretation of data obtained by the use of such machines. In order to overcome the above difficulties which stem largely from uneven load distribution, a versatile testing machine was designed which by use of cheap and easily obtainable components allows the application of a uniformly distributed applied load to a centre cracked test plate. The machine which was commissioned in its original form in 1975 was initially capable of testing plate of 820 mm width and 25 or 48 mm thickness up to maximum stress levels of 488 or 254 MPa respectively. The ease of adaptability of the machine has since permitted its capacity to be increased to handle plate up to 2032 mm wide and 76 mm thickness and by use of double-banked hydraulic jacks stress levels up to 350 MPa can be achieved on plate of these dimensions. The configuration of the machine allows adequate access for strain gauging, crack tip observation and measurements, and temperature control, tests having been conducted in the temperature range -40 0 C to 290 0 C. Advantages and potential for further development of the machine are given together with details of two of a number of fracture studies which have been conducted since its commissioning. (orig.)

  4. A method for generating skewed random numbers using two overlapping uniform distributions

    International Nuclear Information System (INIS)

    Ermak, D.L.; Nasstrom, J.S.

    1995-02-01

    The objective of this work was to implement and evaluate a method for generating skewed random numbers using a combination of uniform random numbers. The method provides a simple and accurate way of generating skewed random numbers from the specified first three moments without an a priori specification of the probability density function. We describe the procedure for generating skewed random numbers from unifon-n random numbers, and show that it accurately produces random numbers with the desired first three moments over a range of skewness values. We also show that in the limit of zero skewness, the distribution of random numbers is an accurate approximation to the Gaussian probability density function. Future work win use this method to provide skewed random numbers for a Langevin equation model for diffusion in skewed turbulence

  5. ACORN—A new method for generating sequences of uniformly distributed Pseudo-random Numbers

    Science.gov (United States)

    Wikramaratna, R. S.

    1989-07-01

    A new family of pseudo-random number generators, the ACORN ( additive congruential random number) generators, is proposed. The resulting numbers are distributed uniformly in the interval [0, 1). The ACORN generators are defined recursively, and the ( k + 1)th order generator is easily derived from the kth order generator. Some theorems concerning the period length are presented and compared with existing results for linear congruential generators. A range of statistical tests are applied to the ACORN generators, and their performance is compared with that of the linear congruential generators and the Chebyshev generators. The tests show the ACORN generators to be statistically superior to the Chebyshev generators, while being statistically similar to the linear congruential generators. However, the ACORN generators execute faster than linear congruential generators for the same statistical faithfulness. The main advantages of the ACORN generator are speed of execution, long period length, and simplicity of coding.

  6. Test system and method

    DEFF Research Database (Denmark)

    2012-01-01

    at a second distance from the centre, the second distance being larger than the first distance, one or more sensors arranged at each fluid channel, wherein the sensors each comprise at least one optical detectable member, the test apparatus further comprising one or more optical sensing devices arranged...... larger than the first distance, one or more sensors arranged at each fluid channel, wherein the sensors each comprise at least one optical detectable member, the test apparatus further comprising one or more optical sensing devices arranged for sensing the at least one optical detectable member...

  7. SPET reconstruction with a non-uniform attenuation coefficient using an analytical regularizing iterative method

    International Nuclear Information System (INIS)

    Soussaline, F.; LeCoq, C.; Raynaud, C.; Kellershohn, C.

    1982-09-01

    The aim of this study is to evaluate the potential of the RIM technique when used in brain studies. The analytical Regulatorizing Iterative Method (RIM) is designed to provide fast and accurate reconstruction of tomographic images when non-uniform attenuation is to be accounted for. As indicated by phantom studies, this method improves the contrast and the signal-to-noise ratio as compared to those obtained with FBP (Filtered Back Projection) technique. Preliminary results obtained in brain studies using AMPI-123 (isopropil-amphetamine I-123) are very encouraging in terms of quantitative regional cellular activity. However, the clinical usefulness of this mathematically accurate reconstruction procedure is going to be demonstrated in our Institution, in comparing quantitative data in heart or liver studies where control values can be obtained

  8. SPET reconstruction with a non-uniform attenuation coefficient using an analytical regularizing iterative method

    International Nuclear Information System (INIS)

    Soussaline, F.; LeCoq, C.; Raynaud, C.; Kellershohn

    1982-01-01

    The potential of the Regularizing Iterative Method (RIM), when used in brain studies, is evaluated. RIM is designed to provide fast and accurate reconstruction of tomographic images when non-uniform attenuation is to be accounted for. As indicated by phantom studies, this method improves the contrast and the signal-to-noise ratio as compared to those obtained with Filtered Back Projection (FBP) technique. Preliminary results obtained in brain studies using isopropil-amphetamine I-123 (AMPI-123) are very encouraging in terms of quantitative regional cellular activity. However, the clinical usefulness of this mathematically accurate reconstruction procedure is going to be demonstrated, in comparing quantitative data in heart or liver studies where control values can be obtained

  9. Impact of uniform electrode current distribution on ETF. [Engineering Test Facility MHD generator

    Science.gov (United States)

    Bents, D. J.

    1982-01-01

    A basic reason for the complexity and sheer volume of electrode consolidation hardware in the MHD ETF Powertrain system is the channel electrode current distribution, which is non-uniform. If the channel design is altered to provide uniform electrode current distribution, the amount of hardware required decreases considerably, but at the possible expense of degraded channel performance. This paper explains the design impacts on the ETF electrode consolidation network associated with uniform channel electrode current distribution, and presents the alternate consolidation designs which occur. They are compared to the baseline (non-uniform current) design with respect to performance, and hardware requirements. A rational basis is presented for comparing the requirements for the different designs and the savings that result from uniform current distribution. Performance and cost impacts upon the combined cycle plant are discussed.

  10. A Non-Uniformly Under-Sampled Blade Tip-Timing Signal Reconstruction Method for Blade Vibration Monitoring

    Directory of Open Access Journals (Sweden)

    Zheng Hu

    2015-01-01

    Full Text Available High-speed blades are often prone to fatigue due to severe blade vibrations. In particular, synchronous vibrations can cause irreversible damages to the blade. Blade tip-timing methods (BTT have become a promising way to monitor blade vibrations. However, synchronous vibrations are unsuitably monitored by uniform BTT sampling. Therefore, non-equally mounted probes have been used, which will result in the non-uniformity of the sampling signal. Since under-sampling is an intrinsic drawback of BTT methods, how to analyze non-uniformly under-sampled BTT signals is a big challenge. In this paper, a novel reconstruction method for non-uniformly under-sampled BTT data is presented. The method is based on the periodically non-uniform sampling theorem. Firstly, a mathematical model of a non-uniform BTT sampling process is built. It can be treated as the sum of certain uniform sample streams. For each stream, an interpolating function is required to prevent aliasing in the reconstructed signal. Secondly, simultaneous equations of all interpolating functions in each sub-band are built and corresponding solutions are ultimately derived to remove unwanted replicas of the original signal caused by the sampling, which may overlay the original signal. In the end, numerical simulations and experiments are carried out to validate the feasibility of the proposed method. The results demonstrate the accuracy of the reconstructed signal depends on the sampling frequency, the blade vibration frequency, the blade vibration bandwidth, the probe static offset and the number of samples. In practice, both types of blade vibration signals can be particularly reconstructed by non-uniform BTT data acquired from only two probes.

  11. Standardized waste form test methods

    International Nuclear Information System (INIS)

    Slate, S.C.

    1984-11-01

    The Materials Characterization Center (MCC) is developing standard tests to characterize nuclear waste forms. Development of the first thirteen tests was originally initiated to provide data to compare different high-level waste (HLW) forms and to characterize their basic performance. The current status of the first thirteen MCC tests and some sample test results is presented: The radiation stability tests (MCC-6 and 12) and the tensile-strength test (MCC-11) are approved; the static leach tests (MCC-1, 2, and 3) are being reviewed for full approval; the thermal stability (MCC-7) and microstructure evaluation (MCC-13) methods are being considered for the first time; and the flowing leach tests methods (MCC-4 and 5), the gas generation methods (MCC-8 and 9), and the brittle fracture method (MCC-10) are indefinitely delayed. Sample static leach test data on the ARM-1 approved reference material are presented. Established tests and proposed new tests will be used to meet new testing needs. For waste form production, tests on stability and composition measurement are needed to provide data to ensure waste form quality. In transportation, data are needed to evaluate the effects of accidents on canisterized waste forms. The new MCC-15 accident test method and some data are presented. Compliance testing needs required by the recent draft repository waste acceptance specifications are described. These specifications will control waste form contents, processing, and performance. 2 references, 2 figures

  12. Standardized waste form test methods

    International Nuclear Information System (INIS)

    Slate, S.C.

    1984-01-01

    The Materials Characterization Center (MCC) is developing standard tests to characterize nuclear waste forms. Development of the first thirteen tests was originally initiated to provide data to compare different high-level waste (HLW) forms and to characterize their basic performance. The current status of the first thirteen MCC tests and some sample test results are presented: the radiation stability tests (MCC-6 and 12) and the tensile-strength test (MCC-11) are approved; the static leach tests (MCC-1, 2, and 3) are being reviewed for full approval; the thermal stability (MCC-7) and microstructure evaluation (MCC-13) methods are being considered for the first time; and the flowing leach test methods (MCC-4 and 5), the gas generation methods (MCC-8 and 9), and the brittle fracture method (MCC-10) are indefinitely delayed. Sample static leach test data on the ARM-1 approved reference material are presented. Established tests and proposed new tests will be used to meet new testing needs. For waste form production, tests on stability and composition measurement are needed to provide data to ensure waste form quality. In transporation, data are needed to evaluate the effects of accidents on canisterized waste forms. The new MCC-15 accident test method and some data are presented. Compliance testing needs required by the recent draft repository waste acceptance specifications are described. These specifications will control waste form contents, processing, and performance

  13. Chapter 21: Estimating Net Savings - Common Practices. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Violette, Daniel M. [Navigant, Boulder, CO (United States); Rathbun, Pamela [Tetra Tech, Madison, WI (United States)

    2017-11-02

    This chapter focuses on the methods used to estimate net energy savings in evaluation, measurement, and verification (EM and V) studies for energy efficiency (EE) programs. The chapter provides a definition of net savings, which remains an unsettled topic both within the EE evaluation community and across the broader public policy evaluation community, particularly in the context of attribution of savings to a program. The chapter differs from the measure-specific Uniform Methods Project (UMP) chapters in both its approach and work product. Unlike other UMP resources that provide recommended protocols for determining gross energy savings, this chapter describes and compares the current industry practices for determining net energy savings but does not prescribe methods.

  14. Chapter 1: Introduction. The Uniform Methods Project: Methods for Determining Energy-Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Li, Michael [Dept. of Energy (DOE), Washington DC (United States). Office of Energy Efficiency and Renewable Energy; Haeri, Hossein [The Cadmus Group, Portland, OR (United States); Reynolds, Arlis [The Cadmus Group, Portland, OR (United States)

    2017-09-28

    This chapter provides a set of model protocols for determining energy and demand savings that result from specific energy efficiency measures implemented through state and utility efficiency programs. The methods described here are approaches that are or are among the most commonly used and accepted in the energy efficiency industry for certain measures or programs. As such, they draw from the existing body of research and best practices for energy efficiency program evaluation, measurement, and verification (EM&V). These protocols were developed as part of the Uniform Methods Project (UMP), funded by the U.S. Department of Energy (DOE). The principal objective for the project was to establish easy-to-follow protocols based on commonly accepted methods for a core set of widely deployed energy efficiency measures.

  15. Testing the Pareto against the lognormal distributions with the uniformly most powerful unbiased test applied to the distribution of cities.

    Science.gov (United States)

    Malevergne, Yannick; Pisarenko, Vladilen; Sornette, Didier

    2011-03-01

    Fat-tail distributions of sizes abound in natural, physical, economic, and social systems. The lognormal and the power laws have historically competed for recognition with sometimes closely related generating processes and hard-to-distinguish tail properties. This state-of-affair is illustrated with the debate between Eeckhout [Amer. Econ. Rev. 94, 1429 (2004)] and Levy [Amer. Econ. Rev. 99, 1672 (2009)] on the validity of Zipf's law for US city sizes. By using a uniformly most powerful unbiased (UMPU) test between the lognormal and the power-laws, we show that conclusive results can be achieved to end this debate. We advocate the UMPU test as a systematic tool to address similar controversies in the literature of many disciplines involving power laws, scaling, "fat" or "heavy" tails. In order to demonstrate that our procedure works for data sets other than the US city size distribution, we also briefly present the results obtained for the power-law tail of the distribution of personal identity (ID) losses, which constitute one of the major emergent risks at the interface between cyberspace and reality.

  16. Influence of Signal Intensity Non-Uniformity on Brain Volumetry Using an Atlas-Based Method

    International Nuclear Information System (INIS)

    Takao, Hidemasa; Kunimatsu, Akira; Mori, Harushi

    2012-01-01

    Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 X[measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials.

  17. Influence of signal intensity non-uniformity on brain volumetry using an atlas-based method.

    Science.gov (United States)

    Goto, Masami; Abe, Osamu; Miyati, Tosiaki; Kabasawa, Hiroyuki; Takao, Hidemasa; Hayashi, Naoto; Kurosu, Tomomi; Iwatsubo, Takeshi; Yamashita, Fumio; Matsuda, Hiroshi; Mori, Harushi; Kunimatsu, Akira; Aoki, Shigeki; Ino, Kenji; Yano, Keiichi; Ohtomo, Kuni

    2012-01-01

    Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 × [measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials.

  18. Influence of Signal Intensity Non-Uniformity on Brain Volumetry Using an Atlas-Based Method

    Energy Technology Data Exchange (ETDEWEB)

    Takao, Hidemasa; Kunimatsu, Akira; Mori, Harushi [University of Tokyo Hospital, Tokyo (Japan); and others

    2012-07-15

    Many studies have reported pre-processing effects for brain volumetry; however, no study has investigated whether non-parametric non-uniform intensity normalization (N3) correction processing results in reduced system dependency when using an atlas-based method. To address this shortcoming, the present study assessed whether N3 correction processing provides reduced system dependency in atlas-based volumetry. Contiguous sagittal T1-weighted images of the brain were obtained from 21 healthy participants, by using five magnetic resonance protocols. After image preprocessing using the Statistical Parametric Mapping 5 software, we measured the structural volume of the segmented images with the WFU-PickAtlas software. We applied six different bias-correction levels (Regularization 10, Regularization 0.0001, Regularization 0, Regularization 10 with N3, Regularization 0.0001 with N3, and Regularization 0 with N3) to each set of images. The structural volume change ratio (%) was defined as the change ratio (%) = (100 X[measured volume - mean volume of five magnetic resonance protocols] / mean volume of five magnetic resonance protocols) for each bias-correction level. A low change ratio was synonymous with lower system dependency. The results showed that the images with the N3 correction had a lower change ratio compared with those without the N3 correction. The present study is the first atlas-based volumetry study to show that the precision of atlas-based volumetry improves when using N3-corrected images. Therefore, correction for signal intensity non-uniformity is strongly advised for multi-scanner or multi-site imaging trials.

  19. Combining the multilevel fast multipole method with the uniform geometrical theory of diffraction

    Directory of Open Access Journals (Sweden)

    A. Tzoulis

    2005-01-01

    Full Text Available The presence of arbitrarily shaped and electrically large objects in the same environment leads to hybridization of the Method of Moments (MoM with the Uniform Geometrical Theory of Diffraction (UTD. The computation and memory complexity of the MoM solution is improved with the Multilevel Fast Multipole Method (MLFMM. By expanding the k-space integrals in spherical harmonics, further considerable amount of memory can be saved without compromising accuracy and numerical speed. However, until now MoM-UTD hybrid methods are restricted to conventional MoM formulations only with Electric Field Integral Equation (EFIE. In this contribution, a MLFMM-UTD hybridization for Combined Field Integral Equation (CFIE is proposed and applied within a hybrid Finite Element - Boundary Integral (FEBI technique. The MLFMM-UTD hybridization is performed at the translation procedure on the various levels of the MLFMM, using a far-field approximation of the corresponding translation operator. The formulation of this new hybrid technique is presented, as well as numerical results.

  20. A novel scene-based non-uniformity correction method for SWIR push-broom hyperspectral sensors

    Science.gov (United States)

    Hu, Bin-Lin; Hao, Shi-Jing; Sun, De-Xin; Liu, Yin-Nian

    2017-09-01

    A novel scene-based non-uniformity correction (NUC) method for short-wavelength infrared (SWIR) push-broom hyperspectral sensors is proposed and evaluated. This method relies on the assumption that for each band there will be ground objects with similar reflectance to form uniform regions when a sufficient number of scanning lines are acquired. The uniform regions are extracted automatically through a sorting algorithm, and are used to compute the corresponding NUC coefficients. SWIR hyperspectral data from airborne experiment are used to verify and evaluate the proposed method, and results show that stripes in the scenes have been well corrected without any significant information loss, and the non-uniformity is less than 0.5%. In addition, the proposed method is compared to two other regular methods, and they are evaluated based on their adaptability to the various scenes, non-uniformity, roughness and spectral fidelity. It turns out that the proposed method shows strong adaptability, high accuracy and efficiency.

  1. Quantitative SPECT reconstruction for brain distribution with a non-uniform attenuation using a regularizing method

    International Nuclear Information System (INIS)

    Soussaline, F.; Bidaut, L.; Raynaud, C.; Le Coq, G.

    1983-06-01

    An analytical solution to the SPECT reconstruction problem, where the actual attenuation effect can be included, was developped using a regularizing iterative method (RIM). The potential of this approach in quantitative brain studies when using a tracer for cerebrovascular disorders is now under evaluation. Mathematical simulations for a distributed activity in the brain surrounded by the skull and physical phantom studies were performed, using a rotating camera based SPECT system, allowing the calibration of the system and the evaluation of the adapted method to be used. On the simulation studies, the contrast obtained along a profile, was less than 5%, the standard deviation 8% and the quantitative accuracy 13%, for a uniform emission distribution of mean = 100 per pixel and a double attenuation coefficient of μ = 0.115 cm -1 and 0.5 cm -1 . Clinical data obtained after injection of 123 I (AMPI) were reconstructed using the RIM without and with cerebrovascular diseases or lesion defects. Contour finding techniques were used for the delineation of the brain and the skull, and measured attenuation coefficients were assumed within these two regions. Using volumes of interest, selected on homogeneous regions on an hemisphere and reported symetrically, the statistical uncertainty for 300 K events in the tomogram was found to be 12%, the index of symetry was of 4% for normal distribution. These results suggest that quantitative SPECT reconstruction for brain distribution is feasible, and that combined with an adapted tracer and an adequate model physiopathological parameters could be extracted

  2. Strategic development of a multivariate calibration model for the uniformity testing of tablets by transmission NIR analysis.

    Science.gov (United States)

    Sasakura, D; Nakayama, K; Sakamoto, T; Chikuma, T

    2015-05-01

    The use of transmission near infrared spectroscopy (TNIRS) is of particular interest in the pharmaceutical industry. This is because TNIRS does not require sample preparation and can analyze several tens of tablet samples in an hour. It has the capability to measure all relevant information from a tablet, while still on the production line. However, TNIRS has a narrow spectrum range and overtone vibrations often overlap. To perform content uniformity testing in tablets by TNIRS, various properties in the tableting process need to be analyzed by a multivariate prediction model, such as a Partial Least Square Regression modeling. One issue is that typical approaches require several hundred reference samples to act as the basis of the method rather than a strategically designed method. This means that many batches are needed to prepare the reference samples; this requires time and is not cost effective. Our group investigated the concentration dependence of the calibration model with a strategic design. Consequently, we developed a more effective approach to the TNIRS calibration model than the existing methodology.

  3. Improving LED CCT uniformity using micropatterned films optimized by combining ray tracing and FDTD methods.

    Science.gov (United States)

    Ding, Xinrui; Li, Jiasheng; Chen, Qiu; Tang, Yong; Li, Zongtao; Yu, Binhai

    2015-02-09

    Although the light-emitting diode (LED) has revolutionized lighting, the non-uniformity of its correlated color temperature (CCT) still remains a major concern. In this context, to improve the light distribution performance of remote phosphor LED lamps, we employ a micropatterned array (MPA) optical film fabricated using a low-cost molding process. The parameters of the MPA, including different installation configurations, positioning, and diameters, are optimized by combining the finite-difference time-domain and ray-tracing methods. Results show that the sample with the upward-facing convex-cone MPA film that has a diameter of half of that of the remote phosphor glass, and is tightly affixed to the inward surface of the remote phosphor glass renders a superior light distribution performance. When compared with the case in which no MPA film is used, the deviation of the CCT distribution decreases from 1033 K to 223 K, and the corresponding output power of the sample is an acceptable level of 85.6%. We perform experiments to verify our simulation results, and the two sets of results exhibit a close agreement. We believe that our approach can be used to optimize MPA films for various lighting applications.

  4. Method to account for dose fractionation in analysis of IMRT plans: Modified equivalent uniform dose

    International Nuclear Information System (INIS)

    Park, Clinton S.; Kim, Yongbok; Lee, Nancy; Bucci, Kara M.; Quivey, Jeanne M.; Verhey, Lynn J.; Xia Ping

    2005-01-01

    Purpose: To propose a modified equivalent uniform dose (mEUD) to account for dose fractionation using the biologically effective dose without losing the advantages of the generalized equivalent uniform dose (gEUD) and to report the calculated mEUD and gEUD in clinically used intensity-modulated radiotherapy (IMRT) plans. Methods and Materials: The proposed mEUD replaces the dose to each voxel in the gEUD formulation by a biologically effective dose with a normalization factor. We propose to use the term mEUD D o /n o that includes the total dose (D o ) and number of fractions (n o ) and to use the term mEUD o that includes the same total dose but a standard fraction size of 2 Gy. A total of 41 IMRT plans for patients with nasopharyngeal cancer treated at our institution between October 1997 and March 2002 were selected for the study. The gEUD and mEUD were calculated for the planning gross tumor volume (pGTV), planning clinical tumor volume (pCTV), parotid glands, and spinal cord. The prescription dose for these patients was 70 Gy to >95% of the pGTV and 59.4 Gy to >95% of the pCTV in 33 fractions. Results: The calculated average gEUD was 72.2 ± 2.4 Gy for the pGTV, 54.2 ± 7.1 Gy for the pCTV, 26.7 ± 4.2 Gy for the parotid glands, and 34.1 ± 6.8 Gy for the spinal cord. The calculated average mEUD D o /n o using 33 fractions was 71.7 ± 3.5 Gy for mEUD 70/33 of the pGTV, 49.9 ± 7.9 Gy for mEUD 59.5/33 of the pCTV, 27.6 ± 4.8 Gy for mEUD 26/33 of the parotid glands, and 32.7 ± 7.8 Gy for mEUD 45/33 of the spinal cord. Conclusion: The proposed mEUD, combining the gEUD with the biologically effective dose, preserves all advantages of the gEUD while reflecting the fractionation effects and linear and quadratic survival characteristics

  5. Standard Test Method for Sandwich Corrosion Test

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method defines the procedure for evaluating the corrosivity of aircraft maintenance chemicals, when present between faying surfaces (sandwich) of aluminum alloys commonly used for aircraft structures. This test method is intended to be used in the qualification and approval of compounds employed in aircraft maintenance operations. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements appear in Section 9.

  6. Methods for Equating Mental Tests.

    Science.gov (United States)

    1984-11-01

    1983) compared conventional and IRT methods for equating the Test of English as a Foreign Language ( TOEFL ) after chaining. Three conventional and...three IRT equating methods were examined in this study; two sections of TOEFL were each (separately) equated. The IRT methods included the following: (a...group. A separate base form was established for each of the six equating methods. Instead of equating the base-form TOEFL to itself, the last (eighth

  7. A METHOD FOR EVALUATION OF NON-UNIFORM RADIANT-CONVECTIVE LOAD ON HUMAN BODY DURING MENTAL WORK

    Directory of Open Access Journals (Sweden)

    Lenka Prokšová Zuská

    2017-10-01

    Full Text Available The objective of this study was to develop a documentation for the amendment of the microclimatic part of the Czech Government Regulation, particularly in a non-uniform radiant-convective load evaluation. Changes in regulation were made based on experimental data obtained on a group of experimental individuals in a climatic chamber. One of the objectives of the climatic chamber experiments was to evaluate whether there was a possibility to use an alternative method, which utilizes a new value – stereotemperature, for the assessment. A group of 24 women was exposed to a non-uniform radiant-convective load in a climatic chamber for 1 hour during their computer work. Measurements were divided according to the globe temperature into 3 stages. The physical parameters of air were continuously measured: the air temperature, globe temperature, air velocity, radiant temperature, relative humidity, stereotemperature and physiological parameters. Thermal sensations of experimental subjects were expressed in the seven-point scale according to EN ISO 7730. The thermal sensation correlated very well with the difference of stereotemperature and the globe temperature. The stereotemperature correlated very well with the radiant temperature. In this work, the composed equations were used to develop the limit values for the thermal stress evaluation in the uniform and non-uniform thermal environment at workplaces. It is possible to determine how the body of an exposed person perceives the non-uniform climatic conditions in the indoor environment, by adding the stereotemperature to government regulations.

  8. Test equating methods and practices

    CERN Document Server

    Kolen, Michael J

    1995-01-01

    In recent years, many researchers in the psychology and statistical communities have paid increasing attention to test equating as issues of using multiple test forms have arisen and in response to criticisms of traditional testing techniques This book provides a practically oriented introduction to test equating which both discusses the most frequently used equating methodologies and covers many of the practical issues involved The main themes are - the purpose of equating - distinguishing between equating and related methodologies - the importance of test equating to test development and quality control - the differences between equating properties, equating designs, and equating methods - equating error, and the underlying statistical assumptions for equating The authors are acknowledged experts in the field, and the book is based on numerous courses and seminars they have presented As a result, educators, psychometricians, professionals in measurement, statisticians, and students coming to the subject for...

  9. Use of Bayesian Methods to Analyze and Visualize Content Uniformity Capability Versus United States Pharmacopeia and ASTM Standards.

    Science.gov (United States)

    Hofer, Jeffrey D; Rauk, Adam P

    2017-02-01

    The purpose of this work was to develop a straightforward and robust approach to analyze and summarize the ability of content uniformity data to meet different criteria. A robust Bayesian statistical analysis methodology is presented which provides a concise and easily interpretable visual summary of the content uniformity analysis results. The visualization displays individual batch analysis results and shows whether there is high confidence that different content uniformity criteria could be met a high percentage of the time in the future. The 3 tests assessed are as follows: (a) United States Pharmacopeia Uniformity of Dosage Units , (b) a specific ASTM E2810 Sampling Plan 1 criterion to potentially be used for routine release testing, and (c) another specific ASTM E2810 Sampling Plan 2 criterion to potentially be used for process validation. The approach shown here could readily be used to create similar result summaries for other potential criteria. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  10. Methods for testing transport models

    International Nuclear Information System (INIS)

    Singer, C.; Cox, D.

    1991-01-01

    Substantial progress has been made over the past year on six aspects of the work supported by this grant. As a result, we have in hand for the first time a fairly complete set of transport models and improved statistical methods for testing them against large databases. We also have initial results of such tests. These results indicate that careful application of presently available transport theories can reasonably well produce a remarkably wide variety of tokamak data

  11. [Inappropriate test methods in allergy].

    Science.gov (United States)

    Kleine-Tebbe, J; Herold, D A

    2010-11-01

    Inappropriate test methods are increasingly utilized to diagnose allergy. They fall into two categories: I. Tests with obscure theoretical basis, missing validity and lacking reproducibility, such as bioresonance, electroacupuncture, applied kinesiology and the ALCAT-test. These methods lack both the technical and clinical validation needed to justify their use. II. Tests with real data, but misleading interpretation: Detection of IgG or IgG4-antibodies or lymphocyte proliferation tests to foods do not allow to separate healthy from diseased subjects, neither in case of food intolerance, allergy or other diagnoses. The absence of diagnostic specificity induces many false positive findings in healthy subjects. As a result unjustified diets might limit quality of life and lead to malnutrition. Proliferation of lymphocytes in response to foods can show elevated rates in patients with allergies. These values do not allow individual diagnosis of hypersensitivity due to their broad variation. Successful internet marketing, infiltration of academic programs and superficial reporting by the media promote the popularity of unqualified diagnostic tests; also in allergy. Therefore, critical observation and quick analysis of and clear comments to unqualified methods by the scientific medical societies are more important than ever.

  12. A novel compensation method for the anode gain non-uniformity of multi-anode photomultiplier tubes.

    Science.gov (United States)

    Lee, Chan Mi; Il Kwon, Sun; Ko, Guen Bae; Ito, Mikiko; Yoon, Hyun Suk; Lee, Dong Soo; Hong, Seong Jong; Lee, Jae Sung

    2012-01-07

    The position-sensitive multi-anode photomultiplier tube (MA-PMT) is widely used in high-resolution scintillation detectors. However, the anode gain nonuniformity of this device is a limiting factor that degrades the intrinsic performance of the detector module. The aim of this work was to develop a gain compensation method for the MA-PMT and evaluate the resulting enhancement in the performance of the detector. The method employs a circuit that is composed only of resistors and is placed between the MA-PMT and a resistive charge division network (RCN) used for position encoding. The goal of the circuit is to divide the output current from each anode, so the same current flows into the RCN regardless of the anode gain. The current division is controlled by the combination of a fixed-value series resistor with an output impedance that is much larger than the input impedance of the RCN, and a parallel resistor, which detours part of the current to ground. PSpice simulations of the compensation circuit and the RCN were performed to determine optimal values for the compensation resistors when used with Hamamatsu H8500 MAPMTs. The intrinsic characteristics of a detector module consisting of this MA-PMT and a lutetium-gadolinium-oxyorthosilicate (LGSO) crystal array were tested with and without the gain compensation method. In simulation, the average coefficient of variation and max/min ratio decreased from 15.7% to 2.7% and 2.0 to 1.2, respectively. In the flood map of the LGSO-H8500 detector, the uniformity of the photopeak position for individual crystals and the energy resolution were much improved. The feasibility of the method was shown by applying it to an octagonal prototype positron emission tomography scanner.

  13. Fluorescent penetration crack testing method

    International Nuclear Information System (INIS)

    Roth, A.

    1979-01-01

    The same cleaning, penetration, washing, development and evaluation agents are used in this method as for known methods. In order to accelerate or shorten the testing, the drying process is performed only to optical dryness of the material surface by blowing on it with pressurized air, the development by simple pressing into or dusting of the material with the developer and the temperature of the washing water is selected within room temperature range. (RW) [de

  14. Longitudinal uniformity, time performances and irradiation test of pure CsI crystals

    Energy Technology Data Exchange (ETDEWEB)

    Angelucci, M. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Atanova, O. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Baccaro, S.; Cemmi, A. [ENEA UTTMAT-IRR, Casaccia R.C., Roma (Italy); Cordelli, M. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Donghia, R., E-mail: raffaella.donghia@lnf.infn.it [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Dipartimento di Fisica, Universitá Roma Tre, Roma (Italy); Giovannella, S.; Happacher, F.; Miscetti, S.; Sarra, I.; Soleti, S.R. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy)

    2016-07-11

    To study an alternative to BaF{sub 2}, as the crystal choice for the Mu2e calorimeter, 13 pure CsI crystals from Opto Materials and ISMA producers have been characterized by determining their light yield (LY) and longitudinal response uniformity (LRU), when read with a UV extended PMT. The crystals show a LY of ~100 p.e./MeV (~150 p.e./MeV) when wrapped with Tyvek and coupled to the PMT without (with) optical grease. The LRU is well represented by a linear slope that is on average δ~ −0.6%/cm. The timing performances of the Opto Materials crystal, read with a UV extended MPPC, have been evaluated with minimum ionizing particles. A timing resolution of ~330 ps (~ 440 ps) is achieved when connecting the photosensor to the MPPC with (without) optical grease. The crystal radiation hardness to a ionization dose has also been studied for one pure CsI crystal from SICCAS. After exposing it to a dose of 900 Gy, a decrease of 33% in the LY is observed while the LRU remains unchanged.

  15. Determining irrigation distribution uniformity and efficiency for nurseries

    Science.gov (United States)

    R. Thomas Fernandez

    2010-01-01

    A simple method for testing the distribution uniformity of overhead irrigation systems is described. The procedure is described step-by-step along with an example. Other uses of distribution uniformity testing are presented, as well as common situations that affect distribution uniformity and how to alleviate them.

  16. An efficient method based on the uniformity principle for synthesis of large-scale heat exchanger networks

    International Nuclear Information System (INIS)

    Zhang, Chunwei; Cui, Guomin; Chen, Shang

    2016-01-01

    Highlights: • Two dimensionless uniformity factors are presented to heat exchange network. • The grouping of process streams reduces the computational complexity of large-scale HENS problems. • The optimal sub-network can be obtained by Powell particle swarm optimization algorithm. • The method is illustrated by a case study involving 39 process streams, with a better solution. - Abstract: The optimal design of large-scale heat exchanger networks is a difficult task due to the inherent non-linear characteristics and the combinatorial nature of heat exchangers. To solve large-scale heat exchanger network synthesis (HENS) problems, two dimensionless uniformity factors to describe the heat exchanger network (HEN) uniformity in terms of the temperature difference and the accuracy of process stream grouping are deduced. Additionally, a novel algorithm that combines deterministic and stochastic optimizations to obtain an optimal sub-network with a suitable heat load for a given group of streams is proposed, and is named the Powell particle swarm optimization (PPSO). As a result, the synthesis of large-scale heat exchanger networks is divided into two corresponding sub-parts, namely, the grouping of process streams and the optimization of sub-networks. This approach reduces the computational complexity and increases the efficiency of the proposed method. The robustness and effectiveness of the proposed method are demonstrated by solving a large-scale HENS problem involving 39 process streams, and the results obtained are better than those previously published in the literature.

  17. Methods for testing transport models

    International Nuclear Information System (INIS)

    Singer, C.; Cox, D.

    1993-01-01

    This report documents progress to date under a three-year contract for developing ''Methods for Testing Transport Models.'' The work described includes (1) choice of best methods for producing ''code emulators'' for analysis of very large global energy confinement databases, (2) recent applications of stratified regressions for treating individual measurement errors as well as calibration/modeling errors randomly distributed across various tokamaks, (3) Bayesian methods for utilizing prior information due to previous empirical and/or theoretical analyses, (4) extension of code emulator methodology to profile data, (5) application of nonlinear least squares estimators to simulation of profile data, (6) development of more sophisticated statistical methods for handling profile data, (7) acquisition of a much larger experimental database, and (8) extensive exploratory simulation work on a large variety of discharges using recently improved models for transport theories and boundary conditions. From all of this work, it has been possible to define a complete methodology for testing new sets of reference transport models against much larger multi-institutional databases

  18. Nonconformal scalar field in uniform isotropic space and the method of Hamiltonian diagonalization

    International Nuclear Information System (INIS)

    Pavlov, Yu.V.

    2001-01-01

    One diagonalized metric Hamiltonian of scalar field with arbitrary relation with curvature in N-dimensional uniform isotropic space. One derived spectrum of energies of the appropriate quasi-particles. One calculated energy of quasi-particle appropriate to the canonical Hamiltonian diagonal shape. One structured a modified tensor of energy-pulse with the following features. In case of conformal scalar field it coincides with the metric tensor of energy-pulse. When it is diagonalized the energies of the appropriate particles of nonconformal field are equal to oscillation frequency and the number of such particles produced in non-stationary metric is the finite one. It is shown that Hamiltonian calculated on the basis of the modified tensor of energy-pulse may be derived as a canonical one at certain selection of variables [ru

  19. A Perception Test of Infrared Images of Soldiers in Camouflaged Uniforms

    Science.gov (United States)

    1998-03-09

    psychology ," Science, pp. 990- 1000, 1973. 3.) Macmillan, N.A., and Creelman , C.D.,I991, Detection Theory: A User’s Guide, Cambridge University Press. 4...levels, using the rating scale method shown in McMillan and Creelman ( 1996). The estimated true d was calculated as the mean of the liberal and

  20. The Design Method of Axial Flow Runners Focusing on Axial Flow Velocity Uniformization and Its Application to an Ultra-Small Axial Flow Hydraulic Turbine

    Directory of Open Access Journals (Sweden)

    Yasuyuki Nishi

    2016-01-01

    Full Text Available We proposed a portable and ultra-small axial flow hydraulic turbine that can generate electric power comparatively easily using the low head of open channels such as existing pipe conduits or small rivers. In addition, we proposed a simple design method for axial flow runners in combination with the conventional one-dimensional design method and the design method of axial flow velocity uniformization, with the support of three-dimensional flow analysis. Applying our design method to the runner of an ultra-small axial flow hydraulic turbine, the performance and internal flow of the designed runner were investigated using CFD analysis and experiment (performance test and PIV measurement. As a result, the runners designed with our design method were significantly improved in turbine efficiency compared to the original runner. Specifically, in the experiment, a new design of the runner achieved a turbine efficiency of 0.768. This reason was that the axial component of absolute velocity of the new design of the runner was relatively uniform at the runner outlet in comparison with that of the original runner, and as a result, the negative rotational flow was improved. Thus, the validity of our design method has been verified.

  1. Development of Dissolution Test Method for Drotaverine ...

    African Journals Online (AJOL)

    Development of Dissolution Test Method for Drotaverine ... Methods: Sink conditions, drug stability and specificity in different dissolution media were tested to optimize a dissolution test .... test by Prism 4.0 software, and differences between ...

  2. Brightness and uniformity measurements of plastic scintillator tiles at the CERN H2 test beam

    Science.gov (United States)

    Chatrchyan, S.; Sirunyan, A. M.; Tumasyan, A.; Litomin, A.; Mossolov, V.; Shumeiko, N.; Van De Klundert, M.; Van Haevermaet, H.; Van Mechelen, P.; Van Spilbeeck, A.; Alves, G. A.; Aldá Júnior, W. L.; Hensel, C.; Carvalho, W.; Chinellato, J.; De Oliveira Martins, C.; Matos Figueiredo, D.; Mora Herrera, C.; Nogima, H.; Prado Da Silva, W. L.; Tonelli Manganote, E. J.; Vilela Pereira, A.; Finger, M.; Finger, M., Jr.; Kveton, A.; Tomsa, J.; Adamov, G.; Tsamalaidze, Z.; Behrens, U.; Borras, K.; Campbell, A.; Costanza, F.; Gunnellini, P.; Lobanov, A.; Melzer-Pellmann, I.-A.; Muhl, C.; Roland, B.; Sahin, M.; Saxena, P.; Hegde, V.; Kothekar, K.; Pandey, S.; Sharma, S.; Beri, S. B.; Bhawandeep, B.; Chawla, R.; Kalsi, A.; Kaur, A.; Kaur, M.; Walia, G.; Bhattacharya, S.; Ghosh, S.; Nandan, S.; Purohit, A.; Sharan, M.; Banerjee, S.; Bhattacharya, S.; Chatterjee, S.; Das, P.; Guchait, M.; Jain, S.; Kumar, S.; Maity, M.; Majumder, G.; Mazumdar, K.; Patil, M.; Sarkar, T.; Juodagalvis, A.; Afanasiev, S.; Bunin, P.; Ershov, Y.; Golutvin, I.; Malakhov, A.; Moisenz, P.; Smirnov, V.; Zarubin, A.; Chadeeva, M.; Chistov, R.; Danilov, M.; Popova, E.; Rusinov, V.; Andreev, Yu.; Dermenev, A.; Karneyeu, A.; Krasnikov, N.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Toms, M.; Zhokin, A.; Baskakov, A.; Belyaev, A.; Boos, E.; Dubinin, M.; Dudko, L.; Ershov, A.; Gribushin, A.; Kaminskiy, A.; Klyukhin, V.; Kodolova, O.; Lokhtin, I.; Miagkov, I.; Obraztsov, S.; Petrushanko, S.; Savrin, V.; Snigirev, A.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Leonidov, A.; Terkulov, A.; Bitioukov, S.; Elumakhov, D.; Kalinin, A.; Krychkine, V.; Mandrik, P.; Petrov, V.; Ryutin, R.; Sobol, A.; Troshin, S.; Volkov, A.; Sekmen, S.; Medvedeva, T.; Rumerio, P.; Adiguzel, A.; Bakirci, N.; Boran, F.; Cerci, S.; Damarseckin, S.; Demiroglu, Z. S.; Dölek, F.; Dozen, C.; Dumanoglu, I.; Eskut, E.; Girgis, S.; Gokbulut, G.; Guler, Y.; Hos, I.; Kangal, E. E.; Kara, O.; Kayis Topaksu, A.; Işik, C.; Kiminsu, U.; Oglakci, M.; Onengut, G.; Ozdemir, K.; Ozturk, S.; Polatoz, A.; Sunar Cerci, D.; Tali, B.; Tok, U. G.; Topakli, H.; Turkcapar, S.; Zorbakir, I. S.; Zorbilmez, C.; Bilin, B.; Isildak, B.; Karapinar, G.; Murat Guler, A.; Ocalan, K.; Yalvac, M.; Zeyrek, M.; Atakisi, I. O.; Gülmez, E.; Kaya, M.; Kaya, O.; Koseyan, O. K.; Ozcelik, O.; Ozkorucuklu, S.; Tekten, S.; Yetkin, E. A.; Yetkin, T.; Cankocak, K.; Sen, S.; Boyarintsev, A.; Grynyov, B.; Levchuk, L.; Popov, V.; Sorokin, P.; Flacher, H.; Borzou, A.; Call, K.; Dittmann, J.; Hatakeyama, K.; Liu, H.; Pastika, N.; Buccilli, A.; Cooper, S. I.; Henderson, C.; West, C.; Arcaro, D.; Gastler, D.; Hazen, E.; Rohlf, J.; Sulak, L.; Wu, S.; Zou, D.; Hakala, J.; Heintz, U.; Kwok, K. H. M.; Laird, E.; Landsberg, G.; Mao, Z.; Yu, D. R.; Gary, J. W.; Ghiasi Shirazi, S. M.; Lacroix, F.; Long, O. R.; Wei, H.; Bhandari, R.; Heller, R.; Stuart, D.; Yoo, J. H.; Chen, Y.; Duarte, J.; Lawhorn, J. M.; Nguyen, T.; Spiropulu, M.; Winn, D.; Abdullin, S.; Apresyan, A.; Apyan, A.; Banerjee, S.; Chlebana, F.; Freeman, J.; Green, D.; Hare, D.; Hirschauer, J.; Joshi, U.; Lincoln, D.; Los, S.; Pedro, K.; Spalding, W. J.; Strobbe, N.; Tkaczyk, S.; Whitbeck, A.; Linn, S.; Markowitz, P.; Martinez, G.; Bertoldi, M.; Hagopian, S.; Hagopian, V.; Kolberg, T.; Baarmand, M. M.; Noonan, D.; Roy, T.; Yumiceva, F.; Bilki, B.; Clarida, W.; Debbins, P.; Dilsiz, K.; Durgut, S.; Gandrajula, R. P.; Haytmyradov, M.; Khristenko, V.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Miller, M.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Schmidt, I.; Snyder, C.; Southwick, D.; Tiras, E.; Yi, K.; Al-bataineh, A.; Bowen, J.; Castle, J.; McBrayer, W.; Murray, M.; Wang, Q.; Kaadze, K.; Maravin, Y.; Mohammadi, A.; Saini, L. K.; Baden, A.; Belloni, A.; Calderon, J. D.; Eno, S. C.; Feng, Y. B.; Ferraioli, C.; Grassi, T.; Hadley, N. J.; Jeng, G.-Y.; Kellogg, R. G.; Kunkle, J.; Mignerey, A.; Ricci-Tam, F.; Shin, Y. H.; Skuja, A.; Yang, Z. S.; Yao, Y.; Brandt, S.; D'Alfonso, M.; Hu, M.; Klute, M.; Niu, X.; Chatterjee, R. M.; Evans, A.; Frahm, E.; Kubota, Y.; Lesko, Z.; Mans, J.; Ruckstuhl, N.; Heering, A.; Karmgard, D. J.; Musienko, Y.; Ruchti, R.; Wayne, M.; Benaglia, A. D.; Mei, K.; Tully, C.; Bodek, A.; de Barbaro, P.; Galanti, M.; Garcia-Bellido, A.; Khukhunaishvili, A.; Lo, K. H.; Vishnevskiy, D.; Zielinski, M.; Agapitos, A.; Amouzegar, M.; Chou, J. P.; Hughes, E.; Saka, H.; Sheffield, D.; Akchurin, N.; Damgov, J.; De Guio, F.; Dudero, P. R.; Faulkner, J.; Gurpinar, E.; Kunori, S.; Lamichhane, K.; Lee, S. W.; Libeiro, T.; Mengke, T.; Muthumuni, S.; Undleeb, S.; Volobouev, I.; Wang, Z.; Goadhouse, S.; Hirosky, R.; Wang, Y.

    2018-01-01

    We study the light output, light collection efficiency and signal timing of a variety of organic scintillators that are being considered for the upgrade of the hadronic calorimeter of the CMS detector. The experimental data are collected at the H2 test-beam area at CERN, using a 150 GeV muon beam. In particular, we investigate the usage of over-doped and green-emitting plastic scintillators, two solutions that have not been extensively considered. We present a study of the energy distribution in plastic-scintillator tiles, the hit efficiency as a function of the hit position, and a study of the signal timing for blue and green scintillators.

  3. Brightness and uniformity measurements of plastic scintillator tiles at the CERN H2 test beam

    Energy Technology Data Exchange (ETDEWEB)

    Chatrchyan, S.; et al.

    2017-09-25

    We study the light output, light collection efficiency and signal timing of a variety of organic scintillators that are being considered for the upgrade of the hadronic calorimeter of the CMS detector. The experimental data are collected at the H2 test-beam area at CERN, using a 150 GeV muon beam. In particular, we investigate the usage of over-doped and green-emitting plastic scintillator, two solutions that have not been extensively considered. We present a study of the energy distribution in plastic-scintillator tiles, the hit efficiency as a function of the hit position, and a study of the signal timing for blue and green scintillators.

  4. Studies on Hepa filter test methods

    International Nuclear Information System (INIS)

    Lee, S.H.; Jon, K.S.; Park, W.J.; Ryoo, R.

    1981-01-01

    The purpose of this study is to compare testing methods of the HEPA filter adopted in other countries with each other, and to design and construct a test duct system to establish testing methods. The American D.O.P. test method, the British NaCl test method and several other independently developed methods are compared. It is considered that the D.O.P. method is most suitable for in-plant and leak tests

  5. An inverse method for the design of TIR collimators to achieve a uniform color light beam

    NARCIS (Netherlands)

    Prins, C.R.; Thije Boonkkamp, ten J.H.M.; Tukker, T.W.; IJzerman, W.L.

    2012-01-01

    Color over Angle (CoA) variation in the light output of white LEDs is a common and unsolved problem. In this article we introduce a new method to reduce CoA variation using a special collimator. The method is based on analytical inverse design methods. We present a numerical algorithm to solve the

  6. An inverse method for the design of TIR collimators to achieve a uniform color light beam

    NARCIS (Netherlands)

    Prins, C.R.; Thije Boonkkamp, ten J.H.M.; Tukker, T.W.; IJzerman, W.L.

    2013-01-01

    Color-over-angle (CoA) variation in the light output of white LEDs is a common and unsolved problem. In this article we introduce a new method to reduce CoA variation using a special collimator. The method is based on analytical inverse design methods. We present a numerical algorithm to solve the

  7. Effect of a uniform magnetic field on dielectric two-phase bubbly flows using the level set method

    International Nuclear Information System (INIS)

    Ansari, M.R.; Hadidi, A.; Nimvari, M.E.

    2012-01-01

    In this study, the behavior of a single bubble in a dielectric viscous fluid under a uniform magnetic field has been simulated numerically using the Level Set method in two-phase bubbly flow. The two-phase bubbly flow was considered to be laminar and homogeneous. Deformation of the bubble was considered to be due to buoyancy and magnetic forces induced from the external applied magnetic field. A computer code was developed to solve the problem using the flow field, the interface of two phases, and the magnetic field. The Finite Volume method was applied using the SIMPLE algorithm to discretize the governing equations. Using this algorithm enables us to calculate the pressure parameter, which has been eliminated by previous researchers because of the complexity of the two-phase flow. The finite difference method was used to solve the magnetic field equation. The results outlined in the present study agree well with the existing experimental data and numerical results. These results show that the magnetic field affects and controls the shape, size, velocity, and location of the bubble. - Highlights: ►A bubble behavior was simulated numerically. ► A single bubble behavior was considered in a dielectric viscous fluid. ► A uniform magnetic field is used to study a bubble behavior. ► Deformation of the bubble was considered using the Level Set method. ► The magnetic field affects the shape, size, velocity, and location of the bubble.

  8. Uniform flow around a circular cylinder in the subcritical range - using the Self-induced angular Moment Method turbulence model

    DEFF Research Database (Denmark)

    Johansson, Jens; Nielsen, Mogens Peter

    The uniform flow around a circular cylinder at Reynolds number 1e5 is simulated in a three dimensional domain by means of the newly developed Self-induced angular Moment Method, SMoM, turbulence model. The global force coefficients, Strouhal number, pressure distributions and wall shear stress...... distributions are compared to experimental findings reported in literature. The SMoM turbulence model is found to provide maximum, minimum and time-mean pressure coefficient distributions in very good agreement with experimental findings....

  9. Simulation of a processes of a moving base coating with uniform films by method of physical deposition

    International Nuclear Information System (INIS)

    Avilov, A.A.; Grigorevskij, A.V.; Dudnik, S.F.; Kiryukhin, N.M.; Klyukovich, V.A.; Sagalovich, V.V.

    1989-01-01

    Computational algorithm is developed for calculating thickness of films deposited by physical methods onto a backing of any shape, moving along a given trajectory. The sugegsted algorithm makes it possible to carry out direct simulation on film deposition process and to optimize sources arrangement for obtaining films with a required degree of uniformity. Condensate distribution on a rotating sphere was calculated and here presented. A satisfactory agreement of calculated values with experimental data on metal films obtained by electron-arc spraying, was established

  10. Synthesis and characterization of uniform silica nanoparticles on nickel substrate by spin coating and sol-gel method

    Science.gov (United States)

    Ngoc Thi Le, Hien; Jeong, Hae Kyung

    2014-01-01

    Spin coating and sol-gel methods are proposed for the preparation of silica nanoparticles on a nickel substrate using silicon tetrachloride, 2-methoxyethanol, and four different types of alkaline solutions. The effects of the type of alkaline solution, concentration of silica solution, and speed of spin coating on the properties of silica nanoparticles are investigated systematically. Uniform spherical shape of silica nanoparticles on Ni with the smallest size are obtained with sodium carbonate among the alkaline solutions after stirring at 70 °C for 6 h and spin-coating at 7000 rpm. Physical and electrochemical properties of the silica particles are investigated.

  11. Effect of scandia doping method on the emission uniformity of scandate cathode with Sc2O3–W matrix

    International Nuclear Information System (INIS)

    Wang, Jinshu; Lai, Chen; Liu, Wei; Yang, Fan; Zhang, Xizhu; Cui, Yuntao; Zhou, Meiling

    2013-01-01

    Graphical abstract: Emission uniformity of the cathodes prepared by mechanical mixing (a) and spray drying method (b). - Highlights: • The emission uniformity of scandate cathodes has been quantitively obtained. • The nanoparticles on the cathode surface lead to the electric field enhancement. • The cathode prepared by spray drying method exhibits good emission uniformity. - Abstract: Scandia doped tungsten matrix dispenser cathodes were manufactured using scandia doped tungsten powder prepared by mechanical mixing, liquid–solid doping and a spray drying method. It is found the macrostructure of the cathode depended on the powder preparation method. The cathode prepared using the powder prepared by spray drying method had a homogenous and porous matrix characterized with grains with a diameter of less than 1 μm and with many nanoparticles distributing uniformly around these grains. The cathode with submicron structure and uniform distribution of scandia exhibited good emission uniformity. The emission uniformity ΔJ/J of the cathode prepared by spray drying method was 0.17, about 6 times lower than that of the cathode prepared by mechanical mixing method. The calculation results showed that the nanoparticles led to electric field enhancement. A Ba–Sc–O multilayer on the cathode surface and nanoparticles distributing mainly on W grains contributed to the emission property of the cathode

  12. Effect of scandia doping method on the emission uniformity of scandate cathode with Sc{sub 2}O{sub 3}–W matrix

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jinshu, E-mail: wangjsh@bjut.edu.cn; Lai, Chen; Liu, Wei; Yang, Fan; Zhang, Xizhu; Cui, Yuntao; Zhou, Meiling

    2013-09-01

    Graphical abstract: Emission uniformity of the cathodes prepared by mechanical mixing (a) and spray drying method (b). - Highlights: • The emission uniformity of scandate cathodes has been quantitively obtained. • The nanoparticles on the cathode surface lead to the electric field enhancement. • The cathode prepared by spray drying method exhibits good emission uniformity. - Abstract: Scandia doped tungsten matrix dispenser cathodes were manufactured using scandia doped tungsten powder prepared by mechanical mixing, liquid–solid doping and a spray drying method. It is found the macrostructure of the cathode depended on the powder preparation method. The cathode prepared using the powder prepared by spray drying method had a homogenous and porous matrix characterized with grains with a diameter of less than 1 μm and with many nanoparticles distributing uniformly around these grains. The cathode with submicron structure and uniform distribution of scandia exhibited good emission uniformity. The emission uniformity ΔJ/J of the cathode prepared by spray drying method was 0.17, about 6 times lower than that of the cathode prepared by mechanical mixing method. The calculation results showed that the nanoparticles led to electric field enhancement. A Ba–Sc–O multilayer on the cathode surface and nanoparticles distributing mainly on W grains contributed to the emission property of the cathode.

  13. Evaluation of uniformity and noise consistency test in computerized tomography; Avaliacao do teste de constancia de uniformidade e ruido em tomografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Garrafiel, Fabricio N.; Lykawka, Rochelle; Bacelar, Alexandre; Anes, Mauricio [Hospital de Clinicas de Porto Alegre (HCPA), Porto Alegre, RS (Brazil); Alva-Sanchez, Mirko S.; Pianoschi, Thatiane [Universidade Federal de Ciencias da Saude de Porto Alegre (UFCSPA), Porto Alegre, RS (Brazil)

    2016-07-01

    The quality control in computed tomography (CT) includes constancy tests concerning CT number measured in a water tank and its response as uniformity, noise and accuracy. Differences to It's performance limits and frequency established by the national legislation and the manufacturers are well known. The objective of this study was to evaluate these tests proceeding the periodicity of national legislation. The tests were conducted over a three equipment of different manufacturers. Each equipment has acquisition parameters and specific phantoms. The equipment presented adequate performance and consistency when compared their results to the limits determined by manufacturers and national legislation. Thus, it is important to evaluate these differences and tailor the testing protocols to meet the established quality requirements. (author)

  14. Automatic Testing with Formal Methods

    NARCIS (Netherlands)

    Tretmans, G.J.; Belinfante, Axel

    1999-01-01

    The use of formal system specifications makes it possible to automate the derivation of test cases from specifications. This allows to automate the whole testing process, not only the test execution part of it. This paper presents the state of the art and future perspectives in testing based on

  15. A practical procedure to improve the accuracy of radiochromic film dosimetry. A integration with a correction method of uniformity correction and a red/blue correction method

    International Nuclear Information System (INIS)

    Uehara, Ryuzo; Tachibana, Hidenobu; Ito, Yasushi; Yoshino, Shinichi; Matsubayashi, Fumiyasu; Sato, Tomoharu

    2013-01-01

    It has been reported that the light scattering could worsen the accuracy of dose distribution measurement using a radiochromic film. The purpose of this study was to investigate the accuracy of two different films, EDR2 and EBT2, as film dosimetry tools. The effectiveness of a correction method for the non-uniformity caused from EBT2 film and the light scattering was also evaluated. In addition the efficacy of this correction method integrated with the red/blue correction method was assessed. EDR2 and EBT2 films were read using a flatbed charge-coupled device scanner (EPSON 10000 G). Dose differences on the axis perpendicular to the scanner lamp movement axis were within 1% with EDR2, but exceeded 3% (Maximum: +8%) with EBT2. The non-uniformity correction method, after a single film exposure, was applied to the readout of the films. A corrected dose distribution data was subsequently created. The correction method showed more than 10%-better pass ratios in dose difference evaluation than when the correction method was not applied. The red/blue correction method resulted in 5%-improvement compared with the standard procedure that employed red color only. The correction method with EBT2 proved to be able to rapidly correct non-uniformity, and has potential for routine clinical intensity modulated radiation therapy (IMRT) dose verification if the accuracy of EBT2 is required to be similar to that of EDR2. The use of red/blue correction method may improve the accuracy, but we recommend we should use the red/blue correction method carefully and understand the characteristics of EBT2 for red color only and the red/blue correction method. (author)

  16. [A practical procedure to improve the accuracy of radiochromic film dosimetry: a integration with a correction method of uniformity correction and a red/blue correction method].

    Science.gov (United States)

    Uehara, Ryuzo; Tachibana, Hidenobu; Ito, Yasushi; Yoshino, Shinichi; Matsubayashi, Fumiyasu; Sato, Tomoharu

    2013-06-01

    It has been reported that the light scattering could worsen the accuracy of dose distribution measurement using a radiochromic film. The purpose of this study was to investigate the accuracy of two different films, EDR2 and EBT2, as film dosimetry tools. The effectiveness of a correction method for the non-uniformity caused from EBT2 film and the light scattering was also evaluated. In addition the efficacy of this correction method integrated with the red/blue correction method was assessed. EDR2 and EBT2 films were read using a flatbed charge-coupled device scanner (EPSON 10000G). Dose differences on the axis perpendicular to the scanner lamp movement axis were within 1% with EDR2, but exceeded 3% (Maximum: +8%) with EBT2. The non-uniformity correction method, after a single film exposure, was applied to the readout of the films. A corrected dose distribution data was subsequently created. The correction method showed more than 10%-better pass ratios in dose difference evaluation than when the correction method was not applied. The red/blue correction method resulted in 5%-improvement compared with the standard procedure that employed red color only. The correction method with EBT2 proved to be able to rapidly correct non-uniformity, and has potential for routine clinical IMRT dose verification if the accuracy of EBT2 is required to be similar to that of EDR2. The use of red/blue correction method may improve the accuracy, but we recommend we should use the red/blue correction method carefully and understand the characteristics of EBT2 for red color only and the red/blue correction method.

  17. A New Method to Implement Resampled Uniform PWM Suitable for Distributed Control of Modular Multilevel Converters

    DEFF Research Database (Denmark)

    Huang, Shaojun; Mathe, Laszlo; Teodorescu, Remus

    2013-01-01

    Two existing methods to implement resampling modulation technique for modular multilevel converter (MMC) (the sampling frequency is a multiple of the carrier frequency) are: the software solution (using a microcontroller) and the hardware solution (using FPGA). The former has a certain level...

  18. A uniform measurement expression for cross method comparison of nanoparticle aggregate size distributions

    DEFF Research Database (Denmark)

    Dudkiewicz, Agnieszka; Wagner, Stephan; Lehner, Angela

    2015-01-01

    Available measurement methods for nanomaterials are based on very different measurement principles and hence produce different values when used on aggregated nanoparticle dispersions. This paper provides a solution for relating measurements of nanomaterials comprised of nanoparticle aggregates de...... and clarifications in current regulations and definitions concerning nanomaterials....

  19. Non-uniform Pressure Distribution in Draw-Bend Friction Test and its Influence on Friction Measurement

    International Nuclear Information System (INIS)

    Kim, Young Suk; Jain, Mukesh K.; Metzger, Don R.

    2005-01-01

    From various draw-bend friction tests with sheet metals at lubricated conditions, it has been unanimously reported that the friction coefficient increases as the pin diameter decreases. However, a proper explanation for this phenomenon has not been given yet. In those experiments, tests were performed for different pin diameters while keeping the same average contact pressure by adjusting applied tension forces. In this paper, pressure profiles at pin/strip contacts and the changes in the pressure profiles depending on pin diameters are investigated using finite element simulations. To study the effect of the pressure profile changes on friction measurements, a non-constant friction model (Stribeck friction model), which is more realistic for the lubricated sheet metal contacts, is implemented into the finite element code and applied to the simulations. The study shows that the non-uniformity of the pressure profile increases and the pin/strip contact angle decreases as the pin diameter decreases, and these phenomena increase the friction coefficient, which is calculated from the strip tension forces using a conventional rope-pulley equation

  20. Ideas on a practical method to make more uniform the measure and the account of doses

    International Nuclear Information System (INIS)

    Boussard, P.; Dollo, R.; De Kerviller, M.; Penneroux, M.

    1992-01-01

    The ICRP 60 publication and its consequences on the revision of CEC regulations and basic norms, discussions on dosimetry of outside workers and more generally on the development of exchanges of information between users have led EDF to question its practices for measuring counting doses. Faced with this wide range of french practices and in a desire for harmonisation, an EDF and CEA work team has established a summary of present methods, an evaluation of the consequences of these different strategies and have then suggested a harmonisation of dosimetric measures based on systematic methodology. (author)

  1. Optimization of the uniformity of a metal flow during continuous extrusion by the Conform method

    Science.gov (United States)

    Lyubanova, A. Sh.; Gorokhov, Yu. V.; Solopko, I. V.; Ziborov, A. Yu.

    2010-03-01

    The scheme of plastic deformation of a billet in a container is considered as part of continuous extrusion by the Conform method. A mathematical model of the motion of a viscoplastic Bingham liquid is used to determine the metal velocity distribution in the plastic-deformation zone. As a result, the optimum angle between the longitudinal axes of the die and container is estimated. This angle is found to be one of the main factors affecting the nonuniformity of deformation when a metal flows into the die. The calculated results are compared to experimental data.

  2. Chapter 2: Commercial and Industrial Lighting Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Gowans, Dakers [Left Fork Energy, Harrison, NY (United States); Telarico, Chad [DNV GL, Mahwah, NJ (United States)

    2017-11-02

    The Commercial and Industrial Lighting Evaluation Protocol (the protocol) describes methods to account for gross energy savings resulting from the programmatic installation of efficient lighting equipment in large populations of commercial, industrial, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. A separate Uniform Methods Project (UMP) protocol, Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol, addresses methods for evaluating savings resulting from lighting control measures such as adding time clocks, tuning energy management system commands, and adding occupancy sensors.

  3. 49 CFR 383.133 - Testing methods.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Testing methods. 383.133 Section 383.133... STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.133 Testing methods. (a) All tests shall be constructed in... must be at least as stringent as the Federal standards. (c) States shall determine specific methods for...

  4. 40 CFR 63.547 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Test methods. 63.547 Section 63.547... Hazardous Air Pollutants from Secondary Lead Smelting § 63.547 Test methods. (a) The following test methods...), and 63.545(e): (1) Method 1 shall be used to select the sampling port location and the number of...

  5. Hydra phantom applicability for carrying out tests of field uniformity in gamma cameras; Aplicabilidade do fantoma hydra para realizacao dos testes de uniformidade de campo em gama camaras

    Energy Technology Data Exchange (ETDEWEB)

    Aragao Filho, Geraldo L., E-mail: geraldo_lemos10@hotmail.com [Centro de Medicina Nuclear de Pernambuco (CEMUPE), Recife, PE (Brazil); Oliveira, Alex C.H., E-mail: oliveira_ach@yahoo.com [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Lopes Filho, Ferdinand J.; Vieira, Jose W., E-mail: ferdinand.lopes@oi.com.br, E-mail: jose-wilson59@live.com [Instituto Federal de Pernambuco (IFPE), Recife, PE (Brazil)

    2014-07-01

    Nuclear Medicine is a medical modality that makes use of radioactive material 'in vivo' in humans, making them a temporary radioactive source. The radiation emitted by the patient's body is detected by a specific equipment, called a gamma camera, creates an image showing the spatial and temporal biodistribution of radioactive material administered to the patient. Therefore, it's of fundamental importance a number of specific measures to make sure that procedure be satisfactory, called quality control. To Nuclear Medicine, quality control of gamma camera has the purpose of ensuring accurate scintillographic imaging, truthful and reliable for the diagnosis, guaranteeing visibility and clarity of details of structures, and also to determine the frequency and the need for preventive maintenance of equipment. To ensure the quality control of the gamma camera it's necessary to use some simulators, called phantom, used in Nuclear Medicine to evaluate system performance, system calibration and simulation of injuries. The goal of this study was to validate a new simulator for nuclear medicine, the Hydra phantom. The phantom was initially built for construction of calibration curves used in radiotherapy planning and quality control in CT. It has similar characteristics to specific phantoms in nuclear medicine, containing inserts and water area. Those inserts are regionally sourced materials, many of them are already used in the literature and based on information about density and interaction of radiation with matter. To verify its efficiency in quality control in Nuclear Medicine, was performed a test for uniformity field, one of the main tests performed daily, so we can verify the ability of the gamma camera to reproduce a uniform distribution of the administered activity in the phantom, been analysed qualitatively, through the image, and quantitatively, through values established for Central Field Of View (CFOV) and Useful Field Of View (UFOV

  6. 77 FR 17457 - Work Group on Alternative Test Methods for Commercial Measuring Devices

    Science.gov (United States)

    2012-03-26

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology Work Group on Alternative... Work Group (WG) to examine alternative methods for testing the accuracy of commercial measuring devices... participates to promote uniformity among the states in laws, regulations, methods, and testing equipment that...

  7. Standard test method for determining residual stresses by the hole-drilling strain-gage method

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 Residual Stress Determination: 1.1.1 This test method specifies a hole-drilling procedure for determining residual stress profiles near the surface of an isotropic linearly elastic material. The test method is applicable to residual stress profile determinations where in-plane stress gradients are small. The stresses may remain approximately constant with depth (“uniform” stresses) or they may vary significantly with depth (“non-uniform” stresses). The measured workpiece may be “thin” with thickness much less than the diameter of the drilled hole or “thick” with thickness much greater than the diameter of the drilled hole. Only uniform stress measurements are specified for thin workpieces, while both uniform and non-uniform stress measurements are specified for thick workpieces. 1.2 Stress Measurement Range: 1.2.1 The hole-drilling method can identify in-plane residual stresses near the measured surface of the workpiece material. The method gives localized measurements that indicate the...

  8. Alternative Test Method for Olefins in Gasoline

    Science.gov (United States)

    This action proposes to allow for an additional alternative test method for olefins in gasoline, ASTM D6550-05. The allowance of this additional alternative test method will provide more flexibility to the regulated industry.

  9. Myasthenia Gravis: Tests and Diagnostic Methods

    Science.gov (United States)

    ... Focus on MG Newsletter MG Quarterly Test & Diagnostic methods In addition to a complete medical and neurological ... How can I help? About MGFA Test & Diagnostic methods Treatment for MG FAQ's Upcoming Events 2018 MG ...

  10. Uniform deposition of uranium hexafluoride (UF6): Standardized mass deposits and controlled isotopic ratios using a thermal fluorination method.

    Science.gov (United States)

    McNamara, Bruce K; O'Hara, Matthew J; Casella, Andrew M; Carter, Jennifer C; Addleman, R Shane; MacFarlan, Paul J

    2016-07-01

    We report a convenient method for the generation of volatile uranium hexafluoride (UF6) from solid uranium oxides and other U compounds, followed by uniform deposition of low levels of UF6 onto sampling coupons. Under laminar flow conditions, UF6 is shown to interact with surfaces within a fixed reactor geometry to a highly predictable degree. We demonstrate the preparation of U deposits that range between approximately 0.01 and 500ngcm(-2). The data suggest the method can be extended to creating depositions at the sub-picogramcm(-2) level. The isotopic composition of the deposits can be customized by selection of the U source materials and we demonstrate a layering technique whereby two U solids, each with a different isotopic composition, are employed to form successive layers of UF6 on a surface. The result is an ultra-thin deposit that bears an isotopic signature that is a composite of the two U sources. The reported deposition method has direct application to the development of unique analytical standards for nuclear safeguards and forensics. Further, the method allows access to very low atomic or molecular coverages of surfaces. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. 30 CFR 27.31 - Testing methods.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Testing methods. 27.31 Section 27.31 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Test Requirements § 27.31 Testing methods. A methane...

  12. 40 CFR 80.3 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Test methods. 80.3 Section 80.3... FUELS AND FUEL ADDITIVES General Provisions § 80.3 Test methods. The lead and phosphorus content of gasoline shall be determined in accordance with test methods set forth in the appendices to this part. [47...

  13. 40 CFR 63.1546 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Test methods. 63.1546 Section 63.1546... Hazardous Air Pollutants for Primary Lead Smelting § 63.1546 Test methods. (a) The following procedure shall....1543(a)(1) through § 63.1543(a)(9) shall be determined according to the following test methods in...

  14. Statistical searches for microlensing events in large, non-uniformly sampled time-domain surveys: A test using palomar transient factory data

    Energy Technology Data Exchange (ETDEWEB)

    Price-Whelan, Adrian M.; Agüeros, Marcel A. [Department of Astronomy, Columbia University, 550 W 120th Street, New York, NY 10027 (United States); Fournier, Amanda P. [Department of Physics, Broida Hall, University of California, Santa Barbara, CA 93106 (United States); Street, Rachel [Las Cumbres Observatory Global Telescope Network, Inc., 6740 Cortona Drive, Suite 102, Santa Barbara, CA 93117 (United States); Ofek, Eran O. [Benoziyo Center for Astrophysics, Weizmann Institute of Science, 76100 Rehovot (Israel); Covey, Kevin R. [Lowell Observatory, 1400 West Mars Hill Road, Flagstaff, AZ 86001 (United States); Levitan, David; Sesar, Branimir [Division of Physics, Mathematics, and Astronomy, California Institute of Technology, Pasadena, CA 91125 (United States); Laher, Russ R.; Surace, Jason, E-mail: adrn@astro.columbia.edu [Spitzer Science Center, California Institute of Technology, Mail Stop 314-6, Pasadena, CA 91125 (United States)

    2014-01-20

    Many photometric time-domain surveys are driven by specific goals, such as searches for supernovae or transiting exoplanets, which set the cadence with which fields are re-imaged. In the case of the Palomar Transient Factory (PTF), several sub-surveys are conducted in parallel, leading to non-uniform sampling over its ∼20,000 deg{sup 2} footprint. While the median 7.26 deg{sup 2} PTF field has been imaged ∼40 times in the R band, ∼2300 deg{sup 2} have been observed >100 times. We use PTF data to study the trade off between searching for microlensing events in a survey whose footprint is much larger than that of typical microlensing searches, but with far-from-optimal time sampling. To examine the probability that microlensing events can be recovered in these data, we test statistics used on uniformly sampled data to identify variables and transients. We find that the von Neumann ratio performs best for identifying simulated microlensing events in our data. We develop a selection method using this statistic and apply it to data from fields with >10 R-band observations, 1.1 × 10{sup 9} light curves, uncovering three candidate microlensing events. We lack simultaneous, multi-color photometry to confirm these as microlensing events. However, their number is consistent with predictions for the event rate in the PTF footprint over the survey's three years of operations, as estimated from near-field microlensing models. This work can help constrain all-sky event rate predictions and tests microlensing signal recovery in large data sets, which will be useful to future time-domain surveys, such as that planned with the Large Synoptic Survey Telescope.

  15. Error response test system and method using test mask variable

    Science.gov (United States)

    Gender, Thomas K. (Inventor)

    2006-01-01

    An error response test system and method with increased functionality and improved performance is provided. The error response test system provides the ability to inject errors into the application under test to test the error response of the application under test in an automated and efficient manner. The error response system injects errors into the application through a test mask variable. The test mask variable is added to the application under test. During normal operation, the test mask variable is set to allow the application under test to operate normally. During testing, the error response test system can change the test mask variable to introduce an error into the application under test. The error response system can then monitor the application under test to determine whether the application has the correct response to the error.

  16. Method for critical current testing

    International Nuclear Information System (INIS)

    Siddall, M.B.; Smathers, D.B.

    1989-01-01

    Superconducting critical current testing software was developed with four important features not feasible with analog test equipment. First, quasi-steady-state sample current conditions are achieved by incrementing sample current, followed by holding some milliseconds until the transient voltage decays before voltage sampling. Then the self-field correction from a helically wound sample is computed and subtracted from each sampled field reading. A copper wire inductively wound shunt which is used for quench protection has a constant measured resistance from which the shunt leakage current is computed and subtracted from the sample current by measuring the shunt voltage after each sample current reading. Finally, the critical current is recomputed from a least squares curve fit to the power law: E=A*In when the correlation coefficient for the fit is high enough to ensure a better result than the raw datum. Comparison with NBS Standard Reference Material (NbTi) and current round robin Nb/sub 3/Sn testing is examined

  17. Characterization of Newly Developed Semisolid Stir Joining Method for Cast Cu Base Alloy (Cu-Al-Si-Fe) and Effect of Stirrer Type on Uniformity of Microstructure

    Science.gov (United States)

    Ferasat, Keyvan; Aashuri, Hossein; Kokabi, Amir Hossein; Nikzad, Siamak; Shafizadeh, Mahdi

    2015-02-01

    In this research, the semisolid stir joining method was used to overcome the problem of hot cracking in welding aluminum and silicon bronzes. Moreover, the effects of grooved and cylindrical tools on the microstructure and mechanical properties of samples were examined. After welding specimens, mechanical tests were carried out to find differences between the cast and welded samples. Optical microscopy and scanning electron microscopy were used to study microstructure. X-ray diffraction was used to investigate compounds formed during casting and welding. The solidus and liquidus temperatures of the alloy were measured by differential scanning calorimetry. In this study, the temperature of the work pieces was raised to 1203 K (930 °C) that is in the semisolid region, and the weld seams were stirred by two different types of tools at the speed of 1600 rpm. Macro and micro-structural analyses show uniformity in the phase distribution for specimens welded by cylindrical tool. Desirable and uniform mechanical properties obtained when the cylindrical tool was used.

  18. Laser beam uniformity and stability using homogenizer-based fiber optic launch method: square core fiber delivery

    Science.gov (United States)

    Lizotte, Todd E.

    2011-03-01

    Over the years, technological achievements within the laser medical diagnostic, treatment, and therapy markets have led to ever increasing requirements for greater control of critical laser beam parameters. Increased laser power/energy stabilization, temporal and spatial beam shaping and flexible laser beam delivery systems with ergonomic focusing or imaging lens systems are sought by leading medical laser system producers. With medical procedures that utilize laser energy, there is a constant emphasis on reducing adverse effects that come about by the laser itself or its optical system, but even when these variables are well controlled the medical professional will still need to deal with the multivariate nature of the human body. Focusing on the variables that can be controlled, such as accurate placement of the laser beam where it will expose a surface being treated as well as laser beam shape and uniformity is critical to minimizing adverse conditions. This paper covers the use of fiber optic beam delivery as a means of defining the beam shape (intensity/power distribution uniformity) at the target plane as well as the use of fiber delivery as a means to allow more flexible articulation of the laser beam over the surface being treated. The paper will present a new concept of using a square core fiber beam delivery design utilizing a unique micro lens array (MLA) launch method that improves the overall stability of the system, by minimizing the impact of the laser instability. The resulting performance of the prototype is presented to demonstrate its stability in comparison to simple lens launch techniques, with an emphasis on homogenization and articulated fiber delivery.

  19. Uniform deposition of uranium hexafluoride (UF6): Standardized mass deposits and controlled isotopic ratios using a thermal fluorination method

    Energy Technology Data Exchange (ETDEWEB)

    McNamara, Bruce K.; O’Hara, Matthew J.; Casella, Andrew M.; Carter, Jennifer C.; Addleman, R. Shane; MacFarlan, Paul J.

    2016-07-01

    Abstract: We report a convenient method for the generation of volatile uranium hexafluoride (UF6) from solid uranium oxides and other uranium compounds, followed by uniform deposition of low levels of UF6 onto sampling coupons. Under laminar flow conditions, UF6 is shown to interact with surfaces within the chamber to a highly predictable degree. We demonstrate the preparation of uranium deposits that range between ~0.01 and 470±34 ng∙cm-2. The data suggest the method can be extended to creating depositions at the sub-picogram∙cm-2 level. Additionally, the isotopic composition of the deposits can be customized by selection of the uranium source materials. We demonstrate a layering technique whereby two uranium solids, each with a different isotopic composition, are employed to form successive layers of UF6 on a surface. The result is an ultra-thin deposit of UF6 that bears an isotopic signature that is a composite of the two uranium sources. The reported deposition method has direct application to the development of unique analytical standards for nuclear safeguards and forensics.

  20. 7 CFR 58.644 - Test methods.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Test methods. 58.644 Section 58.644 Agriculture... Procedures § 58.644 Test methods. (a) Microbiological. Microbiological determinations shall be made in accordance with the methods described in the latest edition of Standard Methods for the Examination of Dairy...

  1. Standard test method for creep-fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the determination of mechanical properties pertaining to creep-fatigue deformation or crack formation in nominally homogeneous materials, or both by the use of test specimens subjected to uniaxial forces under isothermal conditions. It concerns fatigue testing at strain rates or with cycles involving sufficiently long hold times to be responsible for the cyclic deformation response and cycles to crack formation to be affected by creep (and oxidation). It is intended as a test method for fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. The cyclic conditions responsible for creep-fatigue deformation and cracking vary with material and with temperature for a given material. 1.2 The use of this test method is limited to specimens and does not cover testing of full-scale components, structures, or consumer products. 1.3 This test method is primarily ...

  2. Chapter 15: Commercial New Construction Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Keates, Steven [ADM Associates, Inc., Atlanta, GA (United States)

    2017-10-09

    This protocol is intended to describe the recommended method when evaluating the whole-building performance of new construction projects in the commercial sector. The protocol focuses on energy conservation measures (ECMs) or packages of measures where evaluators can analyze impacts using building simulation. These ECMs typically require the use of calibrated building simulations under Option D of the International Performance Measurement and Verification Protocol (IPMVP).

  3. Large-scale uniform ZnO tetrapods on catalyst free glass substrate by thermal evaporation method

    Energy Technology Data Exchange (ETDEWEB)

    Alsultany, Forat H., E-mail: foratusm@gmail.com [School of Physics, USM, 11800 Penang (Malaysia); Hassan, Z. [Institute of Nano-Optoelectronics Research and Technology Laboratory (INOR), USM, 11800 Penang (Malaysia); Ahmed, Naser M. [School of Physics, USM, 11800 Penang (Malaysia)

    2016-07-15

    Highlights: • Investigate the growth of ZnO-Ts on glass substrate by thermal evaporation method. • Glass substrate without any catalyst or a seed layer. • The morphology was controlled by adjusting the temperature of the material and the substrate. • Glass substrate was placed vertically in the quartz tube. - Abstract: Here, we report for the first time the catalyst-free growth of large-scale uniform shape and size ZnO tetrapods on a glass substrate via thermal evaporation method. Three-dimensional networks of ZnO tetrapods have needle–wire junctions, an average leg length of 2.1–2.6 μm, and a diameter of 35–240 nm. The morphology and structure of ZnO tetrapods were investigated by controlling the preparation temperature of each of the Zn powder and the glass substrate under O{sub 2} and Ar gases. Studies were carried out on ZnO tetrapods using X-ray diffraction, field emission scanning electron microscopy, UV–vis spectrophotometer, and a photoluminescence. The results showed that the sample grow in the hexagonal wurtzite structure with preferentially oriented along (002) direction, good crystallinity and high transmittance. The band gap value is about 3.27 eV. Photoluminescence spectrum exhibits a very sharp peak at 378 nm and a weak broad green emission.

  4. Development of an RGB color analysis method for controlling uniformity in a long-length GdBCO coated conductor

    International Nuclear Information System (INIS)

    Kim, Tae-Jin; Lee, Jae-Hun; Lee, Yu-Ri; Moon, Seung-Hyun

    2015-01-01

    Reactive co-evaporation-deposition and reaction (RCE-DR) is a very productive GdBa 2 Cu 3 O 7−x (GdBCO) coated conductor (CC) fabrication process, which involves the fast phase conversion of an amorphous film formed by co-evaporation of three metal sources, Gd, Ba and Cu, and thus reduces the time and cost for fabrication of a GdBCO CC. We routinely use quartz crystal microbalance (QCM) to measure and control the evaporation rates of each metal source to keep a constant nominal composition of the superconducting (SC) layer. However, in the case of kilometre long GdBCO CC fabrication, evaporation rates measured by QCM do not exactly reflect deposition rates onto the substrate as source levels decrease, and thus an RGB color analysis method for quality control is designed. With this RGB color analysis method, it is possible to measure the composition of the converted SC layer very close to the actual composition, even in real time. We set up the RGB color analysis program by establishing a database, where RGB color values are matched to composition of the SC layer, and as a result of applying the program to the RCE-DR process, could fabricate high quality GdBCO CC with average critical current of 561 A cm −1 and 95% uniformity along a 1 km length. (paper)

  5. Chapter 16: Retrocommissioning Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Tiessen, Alex [Posterity Group, Derwood, MD (United States)

    2017-10-09

    Retrocommissioning (RCx) is a systematic process for optimizing energy performance in existing buildings. It specifically focuses on improving the control of energy-using equipment (e.g., heating, ventilation, and air conditioning [HVAC] equipment and lighting) and typically does not involve equipment replacement. Field results have shown proper RCx can achieve energy savings ranging from 5 percent to 20 percent, with a typical payback of two years or less (Thorne 2003). The method presented in this protocol provides direction regarding: (1) how to account for each measure's specific characteristics and (2) how to choose the most appropriate savings verification approach.

  6. Radon barrier: Method of testing airtightness

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Buch-Hansen, Thomas Cornelius

    2017-01-01

    The test method NBI 167/02 Radon membrane: Test of airtightness can be used for determining the airtightness of a radon barrier as a system solution. The test determines the air infiltration through the radon barrier for a number of levels of air pressure differences. The airflow through versus...... of the barrier with the low air pressure, through a well-defined opening, as a modification of the test method in general. Results, obtained using the improved test method, are shown for a number of radon barriers tested....

  7. Chapter 17: Residential Behavior Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Stewart, James [Cadmus, Waltham, MA (United States); Todd, Annika [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-11-01

    Residential behavior-based (BB) programs use strategies grounded in the behavioral and social sciences to influence household energy use. These may include providing households with real-time or delayed feedback about their energy use; supplying energy efficiency education and tips; rewarding households for reducing their energy use; comparing households to their peers; and establishing games, tournaments, and competitions. BB programs often target multiple energy end uses and encourage energy savings, demand savings, or both. Savings from BB programs are usually a small percentage of energy use, typically less than 5 percent. Utilities will continue to implement residential BB programs as large-scale, randomized control trials (RCTs); however, some are now experimenting with alternative program designs that are smaller scale; involve new communication channels such as the web, social media, and text messaging; or that employ novel strategies for encouraging behavior change (for example, Facebook competitions). These programs will create new evaluation challenges and may require different evaluation methods than those currently employed to verify any savings they generate. Quasi-experimental methods, however, require stronger assumptions to yield valid savings estimates and may not measure savings with the same degree of validity and accuracy as randomized experiments.

  8. 30 CFR 36.41 - Testing methods.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Testing methods. 36.41 Section 36.41 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... Requirements § 36.41 Testing methods. Mobile diesel-powered transportation equipment submitted for...

  9. 40 CFR 63.465 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Test methods. 63.465 Section 63.465... Halogenated Solvent Cleaning § 63.465 Test methods. (a) Except as provided in paragraphs (f) and (g) of this... Reference Method 307 in appendix A of this part. (b) Except as provided in paragraph (g) of this section for...

  10. New Graphical Methods and Test Statistics for Testing Composite Normality

    Directory of Open Access Journals (Sweden)

    Marc S. Paolella

    2015-07-01

    Full Text Available Several graphical methods for testing univariate composite normality from an i.i.d. sample are presented. They are endowed with correct simultaneous error bounds and yield size-correct tests. As all are based on the empirical CDF, they are also consistent for all alternatives. For one test, called the modified stabilized probability test, or MSP, a highly simplified computational method is derived, which delivers the test statistic and also a highly accurate p-value approximation, essentially instantaneously. The MSP test is demonstrated to have higher power against asymmetric alternatives than the well-known and powerful Jarque-Bera test. A further size-correct test, based on combining two test statistics, is shown to have yet higher power. The methodology employed is fully general and can be applied to any i.i.d. univariate continuous distribution setting.

  11. Methodology for developing new test methods

    Directory of Open Access Journals (Sweden)

    A. I. Korobko

    2017-06-01

    Full Text Available The paper describes the methodology for developing new test methods and forming solutions for the development of new test methods. The basis of the methodology for developing new test methods is the individual elements of the system and process approaches. They contribute to the development of an effective research strategy for the object, the study of interrelations, the synthesis of an adequate model of the test method. The effectiveness of the developed test method is determined by the correct choice of the set of concepts, their interrelations and mutual influence. This allows you to solve the tasks assigned to achieve the goal. The methodology is based on the use of fuzzy cognitive maps. The question of the choice of the method on the basis of which the model for the formation of solutions is based is considered. The methodology provides for recording a model for a new test method in the form of a finite set of objects. These objects are significant for the test method characteristics. Then a causal relationship is established between the objects. Further, the values of fitness indicators and the observability of the method and metrological tolerance for the indicator are established. The work is aimed at the overall goal of ensuring the quality of tests by improving the methodology for developing the test method.

  12. Cathodic Delamination Accelerated Life Test Method

    National Research Council Canada - National Science Library

    Ramotowski, Thomas S

    2007-01-01

    A method for conducting an accelerated life test of a polymer coated metallic sample includes placing the sample below the water surface in a test tank containing water and an oxygen containing gas...

  13. Thermal test requirements and their verification by different test methods

    International Nuclear Information System (INIS)

    Droste, B.; Wieser, G.; Probst, U.

    1993-01-01

    The paper discusses the parameters influencing the thermal test conditions for type B-packages. Criteria for different test methods (by analytical as well as by experimental means) will be developed. A comparison of experimental results from fuel oil pool and LPG fire tests will be given. (J.P.N.)

  14. Methods for sequential resonance assignment in solid, uniformly 13C, 15N labelled peptides: Quantification and application to antamanide

    International Nuclear Information System (INIS)

    Detken, Andreas; Hardy, Edme H.; Ernst, Matthias; Kainosho, Masatsune; Kawakami, Toru; Aimoto, Saburo; Meier, Beat H.

    2001-01-01

    The application of adiabatic polarization-transfer experiments to resonance assignment in solid, uniformly 13 C- 15 N-labelled polypeptides is demonstrated for the cyclic decapeptide antamanide. A homonuclear correlation experiment employing the DREAM sequence for adiabatic dipolar transfer yields a complete assignment of the C α and aliphatic side-chain 13 C resonances to amino acid types. The same information can be obtained from a TOBSY experiment using the recently introduced P9 1 12 TOBSY sequence, which employs the J couplings as a transfer mechanism. A comparison of the two methods is presented. Except for some aromatic phenylalanine resonances, a complete sequence-specific assignment of the 13 C and 15 N resonances in antamanide is achieved by a series of selective or broadband adiabatic triple-resonance experiments. Heteronuclear transfer by adiabatic-passage Hartmann-Hahn cross polarization is combined with adiabatic homonuclear transfer by the DREAM and rotational-resonance tickling sequences into two- and three-dimensional experiments. The performance of these experiments is evaluated quantitatively

  15. Method for uniformly distributing carbon flakes in a positive electrode, the electrode made thereby and compositions. [Patent application

    Science.gov (United States)

    Mrazek, F.C.; Smaga, J.A.; Battles, J.E.

    1981-01-19

    A positive electrode for a secondary electrochemical cell is described wherein an electrically conductive current collector is in electrical contact with a particulate mixture of gray cast iron and an alkali metal sulfide and an electrolyte including alkali metal halides or alkaline earth metal halides. Also present may be a transition metal sulfide and graphite flakes from the conversion of gray cast iron to iron sulfide. Also disclosed is a method of distributing carbon flakes in a cell wherein there is formed an electrochemical cell of a positive electrode structure of the type described and a suitable electrolyte and a second electrode containing a material capable of alloying with alkali metal ions. The cell is connected to a source of electrical potential to electrochemically convert gray cast iron to an iron sulfide and uniformly to distribute carbon flakes formerly in the gray cast iron throughout the positive electrode while forming an alkali metal alloy in the negative electrode. Also disclosed are compositions useful in preparing positive electrodes.

  16. Generation of uniformly distributed dose points for anatomy-based three-dimensional dose optimization methods in brachytherapy.

    Science.gov (United States)

    Lahanas, M; Baltas, D; Giannouli, S; Milickovic, N; Zamboglou, N

    2000-05-01

    We have studied the accuracy of statistical parameters of dose distributions in brachytherapy using actual clinical implants. These include the mean, minimum and maximum dose values and the variance of the dose distribution inside the PTV (planning target volume), and on the surface of the PTV. These properties have been studied as a function of the number of uniformly distributed sampling points. These parameters, or the variants of these parameters, are used directly or indirectly in optimization procedures or for a description of the dose distribution. The accurate determination of these parameters depends on the sampling point distribution from which they have been obtained. Some optimization methods ignore catheters and critical structures surrounded by the PTV or alternatively consider as surface dose points only those on the contour lines of the PTV. D(min) and D(max) are extreme dose values which are either on the PTV surface or within the PTV. They must be avoided for specification and optimization purposes in brachytherapy. Using D(mean) and the variance of D which we have shown to be stable parameters, achieves a more reliable description of the dose distribution on the PTV surface and within the PTV volume than does D(min) and D(max). Generation of dose points on the real surface of the PTV is obligatory and the consideration of catheter volumes results in a realistic description of anatomical dose distributions.

  17. Validation of a non-uniform meshing algorithm for the 3D-FDTD method by means of a two-wire crosstalk experimental set-up

    Directory of Open Access Journals (Sweden)

    Raúl Esteban Jiménez-Mejía

    2015-06-01

    Full Text Available This paper presents an algorithm used to automatically mesh a 3D computational domain in order to solve electromagnetic interaction scenarios by means of the Finite-Difference Time-Domain -FDTD-  Method. The proposed algorithm has been formulated in a general mathematical form, where convenient spacing functions can be defined for the problem space discretization, allowing the inclusion of small sized objects in the FDTD method and the calculation of detailed variations of the electromagnetic field at specified regions of the computation domain. The results obtained by using the FDTD method with the proposed algorithm have been contrasted not only with a typical uniform mesh algorithm, but also with experimental measurements for a two-wire crosstalk set-up, leading to excellent agreement between theoretical and experimental waveforms. A discussion about the advantages of the non-uniform mesh over the uniform one is also presented.

  18. Validated stability indicating liquid chromatographic determination of ebastine in pharmaceuticals after pre column derivatization: Application to tablets and content uniformity testing

    Directory of Open Access Journals (Sweden)

    Eid Manal

    2011-05-01

    Full Text Available Abstract An accurate, simple, sensitive and selective reversed phase liquid chromatographic method has been developed for the determination of ebastine in its pharmaceutical preparations. The proposed method depends on the complexation ability of the studied drug with Zn2+ ions. Reversed phase chromatography was conducted using an ODS C18 (150 × 4.6 mm id stainless steel column at ambient temperature with UV-detection at 260 nm. A mobile phase containing 0.025%w/v Zn2+ in a mixture of (acetonitril/methanol; 1/4 and Britton Robinson buffer (65:35, v/v adjusted to pH 4.2, has been used for the determination of ebastine at a flow rate of 1 ml/min. The calibration curve was rectilinear over the concentration range of 0.3 - 6.0 μg/ml with a detection limit (LOD of 0.13 μg/ml, and quantification limit (LOQ of 0.26 μg/ml. The proposed method was successfully applied for the analysis of ebastine in its dosage forms, the obtained results were favorably compared with those obtained by a comparison method. Furthermore, content uniformity testing of the studied pharmaceutical formulations was also conducted. The composition of the complex as well as its stability constant was also investigated. Moreover, the proposed method was found to be a stability indicating one and was utilized to investigate the kinetics of alkaline and ultraviolet induced degradation of the drug. The first-order rate constant and half life of the degradation products were calculated.

  19. Helium leak testing methods in nuclear applications

    International Nuclear Information System (INIS)

    Ahmad, Anis

    2004-01-01

    Helium mass-spectrometer leak test is the most sensitive leak test method. It gives very reliable and sensitive test results. In last few years application of helium leak testing has gained more importance due to increased public awareness of safety and environment pollution caused by number of growing chemical and other such industries. Helium leak testing is carried out and specified in most of the critical area applications like nuclear, space, chemical and petrochemical industries

  20. 40 CFR 59.207 - Test methods.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test methods. 59.207 Section 59.207 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Compound Emission Standards for Consumer Products § 59.207 Test methods. Each manufacturer or importer...

  1. Simulation of therapeutic electron beam tracking through a non-uniform magnetic field using finite element method.

    Science.gov (United States)

    Tahmasebibirgani, Mohammad Javad; Maskani, Reza; Behrooz, Mohammad Ali; Zabihzadeh, Mansour; Shahbazian, Hojatollah; Fatahiasl, Jafar; Chegeni, Nahid

    2017-04-01

    In radiotherapy, megaelectron volt (MeV) electrons are employed for treatment of superficial cancers. Magnetic fields can be used for deflection and deformation of the electron flow. A magnetic field is composed of non-uniform permanent magnets. The primary electrons are not mono-energetic and completely parallel. Calculation of electron beam deflection requires using complex mathematical methods. In this study, a device was made to apply a magnetic field to an electron beam and the path of electrons was simulated in the magnetic field using finite element method. A mini-applicator equipped with two neodymium permanent magnets was designed that enables tuning the distance between magnets. This device was placed in a standard applicator of Varian 2100 CD linear accelerator. The mini-applicator was simulated in CST Studio finite element software. Deflection angle and displacement of the electron beam was calculated after passing through the magnetic field. By determining a 2 to 5cm distance between two poles, various intensities of transverse magnetic field was created. The accelerator head was turned so that the deflected electrons became vertical to the water surface. To measure the displacement of the electron beam, EBT2 GafChromic films were employed. After being exposed, the films were scanned using HP G3010 reflection scanner and their optical density was extracted using programming in MATLAB environment. Displacement of the electron beam was compared with results of simulation after applying the magnetic field. Simulation results of the magnetic field showed good agreement with measured values. Maximum deflection angle for a 12 MeV beam was 32.9° and minimum deflection for 15 MeV was 12.1°. Measurement with the film showed precision of simulation in predicting the amount of displacement in the electron beam. A magnetic mini-applicator was made and simulated using finite element method. Deflection angle and displacement of electron beam were calculated. With

  2. Test Methods for Robot Agility in Manufacturing.

    Science.gov (United States)

    Downs, Anthony; Harrison, William; Schlenoff, Craig

    2016-01-01

    The paper aims to define and describe test methods and metrics to assess industrial robot system agility in both simulation and in reality. The paper describes test methods and associated quantitative and qualitative metrics for assessing robot system efficiency and effectiveness which can then be used for the assessment of system agility. The paper describes how the test methods were implemented in a simulation environment and real world environment. It also shows how the metrics are measured and assessed as they would be in a future competition. The test methods described in this paper will push forward the state of the art in software agility for manufacturing robots, allowing small and medium manufacturers to better utilize robotic systems. The paper fulfills the identified need for standard test methods to measure and allow for improvement in software agility for manufacturing robots.

  3. Automated Test Methods for XML Metadata

    Science.gov (United States)

    2017-12-28

    8933 Com (661) 277 8933 email jon.morgan.2.ctr@us.af.mil Secretariat, Range Commanders Council ATTN: TEDT-WS-RCC 1510 Headquarters Avenue White...Sands Missile Range, New Mexico 88002-5110 Phone: DSN 258-1107 Com (575) 678-1107 Fax: DSN 258-7519 Com (575) 678-7519 email ...Method for Testing Syntax The test method is as follows. 1. Initialize the programming environment. 2. Write test application code to use the

  4. A hybrid method combining the Time-Domain Method of Moments, the Time-Domain Uniform Theory of Diffraction and the FDTD

    Directory of Open Access Journals (Sweden)

    A. Becker

    2007-06-01

    Full Text Available In this paper a hybrid method combining the Time-Domain Method of Moments (TD-MoM, the Time-Domain Uniform Theory of Diffraction (TD-UTD and the Finite-Difference Time-Domain Method (FDTD is presented. When applying this new hybrid method, thin-wire antennas are modeled with the TD-MoM, inhomogeneous bodies are modelled with the FDTD and large perfectly conducting plates are modelled with the TD-UTD. All inhomogeneous bodies are enclosed in a so-called FDTD-volume and the thin-wire antennas can be embedded into this volume or can lie outside. The latter avoids the simulation of white space between antennas and inhomogeneous bodies. If the antennas are positioned into the FDTD-volume, their discretization does not need to agree with the grid of the FDTD. By using the TD-UTD large perfectly conducting plates can be considered efficiently in the solution-procedure. Thus this hybrid method allows time-domain simulations of problems including very different classes of objects, applying the respective most appropriate numerical techniques to every object.

  5. Uniform random number generators

    Science.gov (United States)

    Farr, W. R.

    1971-01-01

    Methods are presented for the generation of random numbers with uniform and normal distributions. Subprogram listings of Fortran generators for the Univac 1108, SDS 930, and CDC 3200 digital computers are also included. The generators are of the mixed multiplicative type, and the mathematical method employed is that of Marsaglia and Bray.

  6. Comparison of testing methods for particulate filters

    International Nuclear Information System (INIS)

    Ullmann, W.; Przyborowski, S.

    1983-01-01

    Four testing methods for particulate filters were compared by using the test rigs of the National Board of Nuclear Safety and Radiation Protection: 1) Measurement of filter penetration P as a function of particle size d by using a polydisperse NaC1 test aerosol and a scintillation particle counter; 2) Modified sodium flame test for measurement of total filter penetration P for various polydisperse NaC1 test aerosols; 3) Measurement of total filter penetration P for a polydisperse NaC1 test aerosol labelled with short-lived radon daughter products; 4) Measurement of total filter penetration P for a special paraffin oil test aerosol (oil fog test used in FRG according DIN 24 184, test aerosol A). The investigations were carried out on sheets of glass fibre paper (five grades of paper). Detailed information about the four testing methods and the used particle size distributions is given. The different results of the various methods are the base for the discussion of the most important parameters which influence the filter penetration P. The course of the function P=f(d) shows the great influence of the particle size. As expected there was also found a great dependence both from the test aerosol as well as from the principle and the measuring range of the aerosol-measuring device. The differences between the results of the various test methods are greater the lower the penetration. The use of NaCl test aerosol with various particle size distributions gives great differences for the respective penetration values. On the basis of these results and the values given by Dorman conclusions are made about the investigation of particulate filters both for the determination of filter penetration P as well as for the leak test of installed filters

  7. [Seed quality test methods of Paeonia suffruticosa].

    Science.gov (United States)

    Cao, Ya-Yue; Zhu, Zai-Biao; Guo, Qiao-Sheng; Liu, Li; Wang, Chang-Lin

    2014-11-01

    In order to optimize the testing methods for Paeonia suffruticosa seed quality, and provide basis for establishing seed testing rules and seed quality standard of P. suffruticosa. The seed quality of P. suffruticosa from different producing areas was measured based on the related seed testing regulations. The seed testing methods for quality items of P. suffruticosa was established preliminarily. The samples weight of P. suffruticosa was at least 7 000 g for purity analysis and was at least 700 g for test. The phenotypic observation and size measurement were used for authenticity testing. The 1 000-seed weight was determined by 100-seed method, and the water content was carried out by low temperature drying method (10 hours). After soaking in distilled water for 24 h, the seeds was treated with different temperature stratifications of day and night (25 degrees C/20 degrees C, day/night) in the dark for 60 d. After soaking in the liquor of GA3 300 mg x L(-1) for 24 h, the P. suffruticos seeds were cultured in wet sand at 15 degrees C for 12-60 days for germination testing. Seed viability was tested by TlC method.

  8. testing a consensus conference method by discussing

    African Journals Online (AJOL)

    hi-tech

    2000-10-10

    Oct 10, 2000 ... Objectives: To test the recommended consensus conference methods in Tanzania by discussing the management ... “wrong”, based on recommendations advocated in western ..... future scenarios sponsored the conference.

  9. Accelerated Test Method for Corrosion Protective Coatings

    Data.gov (United States)

    National Aeronautics and Space Administration — This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as...

  10. MODERN METHODS OF FOOD INTOLERANCE TESTING

    Directory of Open Access Journals (Sweden)

    M. Yu. Rosensteyn

    2016-01-01

    Full Text Available Аn analytical review of modern methods of food intolerance diagnostics based on interpretation of markers used in the various tests is рresented. It is shown that tests based on observation of the reaction of specific antibodies of the immune system to food antigens tested, are the most accurate, reliable and representative for the diagnosis of food intolerance.

  11. The fabrication of highly uniform ZnO/CdS core/shell structures using a spin-coating-based successive ion layer adsorption and reaction method

    International Nuclear Information System (INIS)

    Joo, Jinmyoung; Kim, Darae; Yun, Dong-Jin; Jun, Hwichan; Rhee, Shi-Woo; Lee, Jae Sung; Yong, Kijung; Jeon, Sangmin; Kim, Sungjee

    2010-01-01

    We developed a successive ion layer adsorption and reaction method based on spin-coating (spin-SILAR) and applied the method to the fabrication of highly uniform ZnO/CdS core/shell nanowire arrays. Because the adsorption, reaction, and rinsing steps occur simultaneously during spin-coating, the spin-SILAR method does not require rinsing steps between the alternating ion adsorption steps, making the growth process simpler and faster than conventional SILAR methods based on dip-coating (dip-SILAR). The ZnO/CdS core/shell nanowire arrays prepared by spin-SILAR had a denser and more uniform structure than those prepared by dip-SILAR, resulting in the higher power efficiency for use in photoelectrochemical cells.

  12. The fabrication of highly uniform ZnO/CdS core/shell structures using a spin-coating-based successive ion layer adsorption and reaction method

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Jinmyoung; Kim, Darae; Yun, Dong-Jin; Jun, Hwichan; Rhee, Shi-Woo; Lee, Jae Sung; Yong, Kijung; Jeon, Sangmin [System on Chip Chemical Process Research, Department of Chemical Engineering, Pohang University of Science and Technology (POSTECH), Pohang (Korea, Republic of); Kim, Sungjee, E-mail: jeons@postech.ac.kr [Department of Chemistry, Pohang University of Science and Technology (POSTECH), Pohang (Korea, Republic of)

    2010-08-13

    We developed a successive ion layer adsorption and reaction method based on spin-coating (spin-SILAR) and applied the method to the fabrication of highly uniform ZnO/CdS core/shell nanowire arrays. Because the adsorption, reaction, and rinsing steps occur simultaneously during spin-coating, the spin-SILAR method does not require rinsing steps between the alternating ion adsorption steps, making the growth process simpler and faster than conventional SILAR methods based on dip-coating (dip-SILAR). The ZnO/CdS core/shell nanowire arrays prepared by spin-SILAR had a denser and more uniform structure than those prepared by dip-SILAR, resulting in the higher power efficiency for use in photoelectrochemical cells.

  13. ASTM Validates Air Pollution Test Methods

    Science.gov (United States)

    Chemical and Engineering News, 1973

    1973-01-01

    The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)

  14. Standard test method for dynamic tear testing of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1983-01-01

    1.1 This test method covers the dynamic tear (DT) test using specimens that are 3/16 in. to 5/8 in. (5 mm to 16 mm) inclusive in thickness. 1.2 This test method is applicable to materials with a minimum thickness of 3/16 in. (5 mm). 1.3 The pressed-knife procedure described for sharpening the notch tip generally limits this test method to materials with a hardness level less than 36 HRC. Note 1—The designation 36 HRC is a Rockwell hardness number of 36 on Rockwell C scale as defined in Test Methods E 18. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  15. The test of intrinsic uniformity is one of the basic tests to check the status of the detectors of gamma cameras, and as such is contained in RD 1 841/1997 Quality Control in Nuclear Medicine

    International Nuclear Information System (INIS)

    Gonzalez Soto, X. L.; Gonzalez Ruiz, C.; Lopez-Boto, M. A.; Polo Cezon, R.

    2015-01-01

    Spanish Protocol Quality Control Instrumentation in Nuclear Medicine provides guidelines for conducting this test, similar to those established in the NEMA protocol NEMA Protocol for the calculation of the uniformity intrinsic in GAMMA cameras: application and comparison with the SQFTWARE of the manufacturer. it is advisable to conduct a study to ensure that the results for the test of intrinsic uniformity of the software provided by the equipment manufacturer are equivalent to those obtained by applying the protocol recommended by the SEFM before using this software for performing quality control. (Author)

  16. Efficiency Test Method for Electric Vehicle Chargers

    DEFF Research Database (Denmark)

    Kieldsen, Andreas; Thingvad, Andreas; Martinenas, Sergejus

    2016-01-01

    This paper investigates different methods for measuring the charger efficiency of mass produced electric vehicles (EVs), in order to compare the different models. The consumers have low attention to the loss in the charger though the impact on the driving cost is high. It is not a high priority...... different vehicles. A unified method for testing the efficiency of the charger in EVs, without direct access to the component, is presented. The method is validated through extensive tests of the models Renault Zoe, Nissan LEAF and Peugeot iOn. The results show a loss between 15 % and 40 %, which is far...

  17. Standard Test Method for Hot Spot Protection Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method provides a procedure to determine the ability of a photovoltaic (PV) module to endure the long-term effects of periodic “hot spot” heating associated with common fault conditions such as severely cracked or mismatched cells, single-point open circuit failures (for example, interconnect failures), partial (or non-uniform) shadowing or soiling. Such effects typically include solder melting or deterioration of the encapsulation, but in severe cases could progress to combustion of the PV module and surrounding materials. 1.2 There are two ways that cells can cause a hot spot problem; either by having a high resistance so that there is a large resistance in the circuit, or by having a low resistance area (shunt) such that there is a high-current flow in a localized region. This test method selects cells of both types to be stressed. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method....

  18. A well test analysis method accounting for pre-test operations

    International Nuclear Information System (INIS)

    Silin, D.B.; Tsang, C.-F.

    2003-01-01

    We propose to use regular monitoring data from a production or injection well for estimating the formation hydraulic properties in the vicinity of the wellbore without interrupting the operations. In our approach, we select a portion of the pumping data over a certain time interval and then derive our conclusions from analysis of these data. A distinctive feature of the proposed approach differing it form conventional methods is in the introduction of an additional parameter, an effective pre-test pumping rate. The additional parameter is derived based on a rigorous asymptotic analysis of the flow model. Thus, we account for the non-uniform pressure distribution at the beginning of testing time interval caused by pre-test operations at the well. By synthetic and field examples, we demonstrate that deviation of the matching curve from the data that is usually attributed to skin and wellbore storage effects, can also be interpreted through this new parameter. Moreover, with our method, the data curve is matched equally well and the results of the analysis remain stable when the analyzed data interval is perturbed, whereas traditional methods are sensitive to the choice of the data interval. A special efficient minimization procedure has been developed for searching the best fitting parameters. We enhanced our analysis above with a procedure of estimating ambient reservoir pressure and dimensionless wellbore radius. The methods reported here have been implemented in code ODA (Operations Data Analysis). A beta version of the code is available for free testing and evaluation to interested parties

  19. Evaluation model development for sprinkler irrigation uniformity ...

    African Journals Online (AJOL)

    A new evaluation method with accompanying software was developed to precisely calculate uniformity from catch-can test data, assuming sprinkler distribution data to be a continuous variable. Two interpolation steps are required to compute unknown water application depths at grid distribution points from radial ...

  20. The Consequence of Self-field and Non-uniform Current Distribution on Short Sample Tests of Superconducting Cables

    CERN Document Server

    Verweij, A P

    1998-01-01

    Electrical measurements on samples of superconducting cables are usually performed in order to determine the critical current $I_c$ and the n-value, assuming that the voltage U at the transition from the superconducting to the normal state follows the power law, U\\sim($I/I_c$)$^n$. An accurate measurement of $I_c$ and n demands, first of all, good control of temperature and field, and precise measurement of current and voltage. The critical current and n-value of a cable are influenced by the self-field of the cable, an effect that has to be known in order to compare the electrical characteristics of the cable with those of the strands from which it is made. The effect of the self-field is dealt with taking into account the orientation and magnitude of the applied field and the n-value of the strands. An important source of inaccuracy is related to the distribution of the currents among the strands. Non-uniform distributions, mainly caused by non-equal resistances of the connections between the strands of the...

  1. New method to access hyperbranched polymers with uniform structure via one-pot polymerization of inimer in microemulsion.

    Science.gov (United States)

    Min, Ke; Gao, Haifeng

    2012-09-26

    A facile approach is presented for successful synthesis of hyperbranched polymers with high molecular weight and uniform structure by a one-pot polymerization of an inimer in a microemulsion. The segregated space in the microemulsion confined the inimer polymerization and particularly the polymer-polymer reaction within discrete nanoparticles. At the end of polymerization, each nanoparticle contained one hyperbranched polymer that had thousands of inimer units and low polydispersity. The hyperbranched polymers were used as multifunctional macroinitiators for synthesis of "hyper-star" polymers. When a degradable inimer was applied, the hyper-stars showed fast degradation into linear polymer chains with low molecular weight.

  2. Advanced Testing Method for Ground Thermal Conductivity

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Xiaobing [ORNL; Clemenzi, Rick [Geothermal Design Center Inc.; Liu, Su [University of Tennessee (UT)

    2017-04-01

    A new method is developed that can quickly and more accurately determine the effective ground thermal conductivity (GTC) based on thermal response test (TRT) results. Ground thermal conductivity is an important parameter for sizing ground heat exchangers (GHEXs) used by geothermal heat pump systems. The conventional GTC test method usually requires a TRT for 48 hours with a very stable electric power supply throughout the entire test. In contrast, the new method reduces the required test time by 40%–60% or more, and it can determine GTC even with an unstable or intermittent power supply. Consequently, it can significantly reduce the cost of GTC testing and increase its use, which will enable optimal design of geothermal heat pump systems. Further, this new method provides more information about the thermal properties of the GHEX and the ground than previous techniques. It can verify the installation quality of GHEXs and has the potential, if developed, to characterize the heterogeneous thermal properties of the ground formation surrounding the GHEXs.

  3. Multipath interference test method for distributed amplifiers

    Science.gov (United States)

    Okada, Takahiro; Aida, Kazuo

    2005-12-01

    A method for testing distributed amplifiers is presented; the multipath interference (MPI) is detected as a beat spectrum between the multipath signal and the direct signal using a binary frequency shifted keying (FSK) test signal. The lightwave source is composed of a DFB-LD that is directly modulated by a pulse stream passing through an equalizer, and emits the FSK signal of the frequency deviation of about 430MHz at repetition rate of 80-100 kHz. The receiver consists of a photo-diode and an electrical spectrum analyzer (ESA). The base-band power spectrum peak appeared at the frequency of the FSK frequency deviation can be converted to amount of MPI using a calibration chart. The test method has improved the minimum detectable MPI as low as -70 dB, compared to that of -50 dB of the conventional test method. The detailed design and performance of the proposed method are discussed, including the MPI simulator for calibration procedure, computer simulations for evaluating the error caused by the FSK repetition rate and the fiber length under test and experiments on singlemode fibers and distributed Raman amplifier.

  4. Assessment of 12 CHF prediction methods, for an axially non-uniform heat flux distribution, with the RELAP5 computer code

    Energy Technology Data Exchange (ETDEWEB)

    Ferrouk, M. [Laboratoire du Genie Physique des Hydrocarbures, University of Boumerdes, Boumerdes 35000 (Algeria)], E-mail: m_ferrouk@yahoo.fr; Aissani, S. [Laboratoire du Genie Physique des Hydrocarbures, University of Boumerdes, Boumerdes 35000 (Algeria); D' Auria, F.; DelNevo, A.; Salah, A. Bousbia [Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione, Universita di Pisa (Italy)

    2008-10-15

    The present article covers the evaluation of the performance of twelve critical heat flux methods/correlations published in the open literature. The study concerns the simulation of an axially non-uniform heat flux distribution with the RELAP5 computer code in a single boiling water reactor channel benchmark problem. The nodalization scheme employed for the considered particular geometry, as modelled in RELAP5 code, is described. For this purpose a review of critical heat flux models/correlations applicable to non-uniform axial heat profile is provided. Simulation results using the RELAP5 code and those obtained from our computer program, based on three type predictions methods such as local conditions, F-factor and boiling length average approaches were compared.

  5. Standard Test Method for Measuring Dose for Use in Linear Accelerator Pulsed Radiation Effects Tests

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This test method covers a calorimetric measurement of the total dose delivered in a single pulse of electrons from an electron linear accelerator or a flash X-ray machine (FXR, e-beam mode) used as an ionizing source in radiation-effects testing. The test method is designed for use with pulses of electrons in the energy range from 10 to 50 MeV and is only valid for cases in which both the calorimeter and the test specimen to be irradiated are“thin” compared to the range of these electrons in the materials of which they are constructed. 1.2 The procedure described can be used in those cases in which (1) the dose delivered in a single pulse is 5 Gy (matl) (500 rd (matl)) or greater, or (2) multiple pulses of a lower dose can be delivered in a short time compared to the thermal time constant of the calorimeter. Matl refers to the material of the calorimeter. The minimum dose per pulse that can be acceptably monitored depends on the variables of the particular test, including pulse rate, pulse uniformity...

  6. Test strip and method for its use

    International Nuclear Information System (INIS)

    1981-01-01

    A test strip device is described which is useful in performing binding assays involving antigens, antibodies, hormones, vitamins, metabolites or pharmacological agents. The device is capable of application to analytical methods in which a set of sequential test reactions is involved and in which a minute sample size may be used. This test strip is particularly useful in radioimmunoassays. The use of the device is illustrated in radioimmunoassays for 1) thyroxine in serum, 2) the triiodothyronine binding capacity of serum and 3) folic acid and its analogues in serum. (U.K.)

  7. Skin carcinogenesis following uniform and non-uniform β irradiation

    International Nuclear Information System (INIS)

    Charles, M.W.; Williams, J.P.; Coggle, J.E.

    1989-01-01

    Where workers or the general public may be exposed to ionising radiation, the irradiation is rarely uniform. The risk figures and dose limits recommended by the International Commission on Radiological Protection (ICRP) are based largely on clinical and epidemiological studies of reasonably uniform irradiated organs. The paucity of clinical or experimental data for highly non-uniform exposures has prevented the ICRP from providing adequate recommendations. This weakness has led on a number of occasions to the postulate that highly non-uniform exposures of organs could be 100,000 times more carcinogenic than ICRP risk figures would predict. This so-called ''hot-particle hypothesis'' found little support among reputable radiobiologists, but could not be clearly and definitively refuted on the basis of experiment. An experiment, based on skin tumour induction in mouse skin, is described which was developed to test the hypothesis. The skin of 1200 SAS/4 male mice has been exposed to a range of uniform and non-uniform sources of the β emitter 170 Tm (E max ∼ 1 MeV). Non-uniform exposures were produced using arrays of 32 or 8 2-mm diameter sources distributed over the same 8-cm 2 area as a uniform control source. Average skin doses varied from 2-100 Gy. The results for the non-uniform sources show a 30% reduction in tumour incidence by the 32-point array at the lower mean doses compared with the response from uniform sources. The eight-point array showed an order-of-magnitude reduction in tumour incidence compared to uniform irradiation at low doses. These results, in direct contradiction to the ''hot particle hypothesis'', indicate that non-uniform exposures produce significantly fewer tumours than uniform exposures. (author)

  8. Evaluation of nitrous oxide as a substitute for sulfur hexafluoride to reduce global warming impacts of ANSI/HPS N13.1 gaseous uniformity testing

    Science.gov (United States)

    Yu, Xiao-Ying; Barnett, J. Matthew; Amidan, Brett G.; Recknagle, Kurtis P.; Flaherty, Julia E.; Antonio, Ernest J.; Glissmeyer, John A.

    2018-03-01

    The ANSI/HPS N13.1-2011 standard requires gaseous tracer uniformity testing for sampling associated with stacks used in radioactive air emissions. Sulfur hexafluoride (SF6), a greenhouse gas with a high global warming potential, has long been the gas tracer used in such testing. To reduce the impact of gas tracer tests on the environment, nitrous oxide (N2O) was evaluated as a potential replacement to SF6. The physical evaluation included the development of a test plan to record percent coefficient of variance and the percent maximum deviation between the two gases while considering variables such as fan configuration, injection position, and flow rate. Statistical power was calculated to determine how many sample sets were needed, and computational fluid dynamic modeling was utilized to estimate overall mixing in stacks. Results show there are no significant differences between the behaviors of the two gases, and SF6 modeling corroborated N2O test results. Although, in principle, all tracer gases should behave in an identical manner for measuring mixing within a stack, the series of physical tests guided by statistics was performed to demonstrate the equivalence of N2O testing to SF6 testing in the context of stack qualification tests. The results demonstrate that N2O is a viable choice leading to a four times reduction in global warming impacts for future similar compliance driven testing.

  9. Standard test methods for bend testing of material for ductility

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover bend testing for ductility of materials. Included in the procedures are four conditions of constraint on the bent portion of the specimen; a guided-bend test using a mandrel or plunger of defined dimensions to force the mid-length of the specimen between two supports separated by a defined space; a semi-guided bend test in which the specimen is bent, while in contact with a mandrel, through a specified angle or to a specified inside radius (r) of curvature, measured while under the bending force; a free-bend test in which the ends of the specimen are brought toward each other, but in which no transverse force is applied to the bend itself and there is no contact of the concave inside surface of the bend with other material; a bend and flatten test, in which a transverse force is applied to the bend such that the legs make contact with each other over the length of the specimen. 1.2 After bending, the convex surface of the bend is examined for evidence of a crack or surface irregu...

  10. Supplementary test method for carbon filters

    International Nuclear Information System (INIS)

    Normann, B.; Pettersson, S.-O.

    1980-11-01

    A test method for carbon filters using freon to detect leakage is described. The filters are used in nuclear power plants and in air-raid shelters to separate radioactive iodine.Sampling and detection limits are described and a proposal for a complete equipment is made.(G.B.)

  11. Validation of qualitative microbiological test methods

    NARCIS (Netherlands)

    IJzerman-Boon, Pieta C.; van den Heuvel, Edwin R.

    2015-01-01

    This paper considers a statistical model for the detection mechanism of qualitative microbiological test methods with a parameter for the detection proportion (the probability to detect a single organism) and a parameter for the false positive rate. It is demonstrated that the detection proportion

  12. Standard test method for creep-fatigue crack growth testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers the determination of creep-fatigue crack growth properties of nominally homogeneous materials by use of pre-cracked compact type, C(T), test specimens subjected to uniaxial cyclic forces. It concerns fatigue cycling with sufficiently long loading/unloading rates or hold-times, or both, to cause creep deformation at the crack tip and the creep deformation be responsible for enhanced crack growth per loading cycle. It is intended as a guide for creep-fatigue testing performed in support of such activities as materials research and development, mechanical design, process and quality control, product performance, and failure analysis. Therefore, this method requires testing of at least two specimens that yield overlapping crack growth rate data. The cyclic conditions responsible for creep-fatigue deformation and enhanced crack growth vary with material and with temperature for a given material. The effects of environment such as time-dependent oxidation in enhancing the crack growth ra...

  13. The Use of Conditional Probability Integral Transformation Method for Testing Accelerated Failure Time Models

    Directory of Open Access Journals (Sweden)

    Abdalla Ahmed Abdel-Ghaly

    2016-06-01

    Full Text Available This paper suggests the use of the conditional probability integral transformation (CPIT method as a goodness of fit (GOF technique in the field of accelerated life testing (ALT, specifically for validating the underlying distributional assumption in accelerated failure time (AFT model. The method is based on transforming the data into independent and identically distributed (i.i.d Uniform (0, 1 random variables and then applying the modified Watson statistic to test the uniformity of the transformed random variables. This technique is used to validate each of the exponential, Weibull and lognormal distributions' assumptions in AFT model under constant stress and complete sampling. The performance of the CPIT method is investigated via a simulation study. It is concluded that this method performs well in case of exponential and lognormal distributions. Finally, a real life example is provided to illustrate the application of the proposed procedure.

  14. Characterization methods for ultrasonic test systems

    International Nuclear Information System (INIS)

    Busse, L.J.; Becker, F.L.; Bowey, R.E.; Doctor, S.R.; Gribble, R.P.; Posakony, G.J.

    1982-07-01

    Methods for the characterization of ultrasonic transducers (search units) and instruments are presented. The instrument system is considered as three separate components consisting of a transducer, a receiver-display, and a pulser. The operation of each component is assessed independently. The methods presented were chosen because they provide the greatest amount of information about component operation and were not chosen based upon such conditions as cost, ease of operation, field implementation, etc. The results of evaluating a number of commercially available ultrasonic test instruments are presented

  15. Thermal Testing Methods for Solar Dryers

    DEFF Research Database (Denmark)

    Singh, Shobhana

    2017-01-01

    Solar food drying is a complex heat and mass transfer phenomena which depend on a number of drying process-dependent parameters such as operating conditions and characteristics of the food product to be dried. The variation in these parameters significantly affects the overall performance...... of the dryer system. Since commercial growth and acceptance of any solar dryer system momentously depend on its performance guarantee, the development of a standard methodology for their thermal testing has become necessary. The standard testing method not only provides better performance management...... of the dryer system but allows the manufacturers to achieve competitive efficiency and good product quality by comparing the available designs. In this chapter, an extensive review of solar dryer performance evaluation has been carried out. Furthermore, the chapter describes the existing testing procedures...

  16. A method for producing uniform dose distributions in the junction regions of large hinge angle electrol fields

    International Nuclear Information System (INIS)

    Zavgorodni, S.F.; Beckham, W.A.; Roos, D.E.

    1996-01-01

    The planning problems presented by abutting electron fields are well recognised. Junctioning electron fields with large hinge angle compounds the problems because of the creation of closely situated 'hot' and 'cold' spots. The technique involving a compensated superficial x-ray (SXR) field to treat the junction region between electron fields was developed and used in a particular clinical case (treatment of a squamous cell carcinoma of the forehead/scalp). The SXR beam parameters were chosen and the compensator was designed to make the SXR field complementary to the electron fields. Application of a compensated SXR field eliminated 'cold' spots in the junction region and minimised 'hot' spots to (110%). In the clinical case discusses the 'hot' spots due to the SXR field would not appear because of increased attenuation of the soft x-rays in bone. The technique proposed produces uniform dose distribution up to 3 cm deep and can be considered as an additional tool for dealing with electron fields junctioning problems. (author)

  17. Prediction of liquid film dryout in two-phase annular-mist flow in a uniformly heated narrow tube development of analytical method under BWR conditions

    International Nuclear Information System (INIS)

    Utsuno, Hideaki; Kaminaga, Fumito

    1998-01-01

    A method was developed based on the conservation lows to predict critical heat flux (CHF) causing liquid film dryout in two-phase annular-mist flow in a uniformly heated narrow tube under BWR conditions. The applicable range of the method is within the pressure of 3-9 MPa, mass flux of 500-2,000 kg/m 2 ·s, heat flux of 0.33-2.0 MW/m 2 and boiling length-to-tube diameter ratio of 200-800. The two-phase annular-mist flow was modeled with the three-fluid streams with liquid film, entrained droplets and gas flow. Governing equations of the method are mass continuity and energy conservation on the three-fluid streams. Constitutive equations on the mass transfer which consist of the entrainment fraction at equilibrium and the mass transfer coefficient were newly proposed in this study. Confirmation of the present method were performed in comparison with the available film flow measurements and various CHF data from experiments in uniformly heated narrow tubes under high pressure steam-water conditions. In the heat flux range (q'' 2 ) practical for a BWR, agreement of the present method with CHF data was obtained as, (Averaged ratio) ± (Standard deviation) = 0.984 ± 0.077, which was shown to be the same or better agreement than the widely-used CHF correlations. (author)

  18. Assessing Social Isolation: Pilot Testing Different Methods.

    Science.gov (United States)

    Taylor, Harry Owen; Herbers, Stephanie; Talisman, Samuel; Morrow-Howell, Nancy

    2016-04-01

    Social isolation is a significant public health problem among many older adults; however, most of the empirical knowledge about isolation derives from community-based samples. There has been less attention given to isolation in senior housing communities. The objectives of this pilot study were to test two methods to identify socially isolated residents in low-income senior housing and compare findings about the extent of isolation from these two methods. The first method, self-report by residents, included 47 out of 135 residents who completed in-person interviews. To determine self-report isolation, residents completed the Lubben Social Network Scale 6 (LSNS-6). The second method involved a staff member who reported the extent of isolation on all 135 residents via an online survey. Results indicated that 26% of residents who were interviewed were deemed socially isolated by the LSNS-6. Staff members rated 12% of residents as having some or a lot of isolation. In comparing the two methods, staff members rated 2% of interviewed residents as having a lot of isolation. The combination of self-report and staff report could be more informative than just self-report alone, particularly when participation rates are low. However, researchers should be aware of the potential discrepancy between these two methods.

  19. Simplified pressure method for respirator fit testing.

    Science.gov (United States)

    Han, D; Xu, M; Foo, S; Pilacinski, W; Willeke, K

    1991-08-01

    A simplified pressure method has been developed for fit testing air-purifying respirators. In this method, the air-purifying cartridges are replaced by a pressure-sensing attachment and a valve. While wearers hold their breath, a small pump extracts air from the respirator cavity until a steady-state pressure is reached in 1 to 2 sec. The flow rate through the face seal leak is a unique function of this pressure, which is determined once for all respirators, regardless of the respirator's cavity volume or deformation because of pliability. The contaminant concentration inside the respirator depends on the degree of dilution by the flow through the cartridges. The cartridge flow varies among different brands and is measured once for each brand. The ratio of cartridge to leakflow is a measure of fit. This flow ratio has been measured on human subjects and has been compared to fit factors determined on the same subjects by means of photometric and particle count tests. The aerosol tests gave higher values of fit.

  20. Semi-exact solution of elastic non-uniform thickness and density rotating disks by homotopy perturbation and Adomian's decomposition methods. Part I: Elastic solution

    International Nuclear Information System (INIS)

    Hojjati, M.H.; Jafari, S.

    2008-01-01

    In this work, two powerful analytical methods, namely homotopy perturbation method (HPM) and Adomian's decomposition method (ADM), are introduced to obtain distributions of stresses and displacements in rotating annular elastic disks with uniform and variable thicknesses and densities. The results obtained by these methods are then compared with the verified variational iteration method (VIM) solution. He's homotopy perturbation method which does not require a 'small parameter' has been used and a homotopy with an imbedding parameter p element of [0,1] is constructed. The method takes the full advantage of the traditional perturbation methods and the homotopy techniques and yields a very rapid convergence of the solution. Adomian's decomposition method is an iterative method which provides analytical approximate solutions in the form of an infinite power series for nonlinear equations without linearization, perturbation or discretization. Variational iteration method, on the other hand, is based on the incorporation of a general Lagrange multiplier in the construction of correction functional for the equation. This study demonstrates the ability of the methods for the solution of those complicated rotating disk cases with either no or difficult to find fairly exact solutions without the need to use commercial finite element analysis software. The comparison among these methods shows that although the numerical results are almost the same, HPM is much easier, more convenient and efficient than ADM and VIM

  1. Characterization and Beam Tests Results of Non-Uniformly Irradiated 3D Pixel Sensors for HEP Experiments

    International Nuclear Information System (INIS)

    Lopez, I.; Grinstein, S.; Micelli, A.; Tsiskaridze, S.

    2013-06-01

    3D Pixel detectors, with cylindrical electrodes that penetrate the silicon substrate, offer advantages over standard planar sensors in terms of radiation hardness, since the charge collection distance can be reduced independently of the bulk thickness. In the framework of the ATLAS Forward Physics (AFP) program, work has been carried out to study the suitability of 3D pixel devices for forward proton tracking. The AFP tracker unit will consist of an array of five pixel sensors placed at 2-3 mm from the Large Hadron Collider (LHC) proton beam. The proximity to the beam is essential for the AFP physics program as it directly increases the sensitivity of the experiment. Thus, there are two critical requirements for the AFP pixel detector. First, the dead region of the sensor has to be minimized. Second, the device has to be able to cope with a very inhomogeneous radiation distribution. Recent results of the characterization and beam test studies of in-homogeneously irradiated 3D pixel sensors produced at CNM-Barcelona will be presented. (authors)

  2. 2-d Simulations of Test Methods

    DEFF Research Database (Denmark)

    Thrane, Lars Nyholm

    2004-01-01

    One of the main obstacles for the further development of self-compacting concrete is to relate the fresh concrete properties to the form filling ability. Therefore, simulation of the form filling ability will provide a powerful tool in obtaining this goal. In this paper, a continuum mechanical...... approach is presented by showing initial results from 2-d simulations of the empirical test methods slump flow and L-box. This method assumes a homogeneous material, which is expected to correspond to particle suspensions e.g. concrete, when it remains stable. The simulations have been carried out when...... using both a Newton and Bingham model for characterisation of the rheological properties of the concrete. From the results, it is expected that both the slump flow and L-box can be simulated quite accurately when the model is extended to 3-d and the concrete is characterised according to the Bingham...

  3. Weighted backprojection implemented with a non-uniform attenuation map for improved SPECT quantitation

    International Nuclear Information System (INIS)

    Manglos, S.H.; Jaszczak, R.J.; Floyd, C.E.

    1988-01-01

    A method is developed to improve quantitation in SPECT imaging by using an attenuation compensation method which includes the correct non-uniform attenuation spatial distribution (''map''). The method is based on the technique of weighted back projection, previously developed for uniform attenuation. The method is tested by imaging a non-uniform phantom, reconstructing with the known attenuation map, and quantitatively comparing the resultant image with the known activity distribution. Reconstructed image profiles are dramatically improved in comparison to reconstructions without compensation or with an assumed uniform attenuation map. Contrast measurements further quantify the improvement. Line spread function distortions seen previously in non-uniform geometries are essentially eliminated by the method. Therefore, the method appears to be appropriate for these geometries, if the non-uniform map can be determined. Some additional image distortions introduced by the compensation method are noted and will require further study

  4. Fission track dating method: I. Study of neutron flux uniformity in some irradiation positions of IEA-R1 reactor

    International Nuclear Information System (INIS)

    Osorio, A.M.; Hadler, J.C.; Iunes, P.J.; Paulo, S.R. de

    1993-06-01

    In order to use the fission track dating method the flux gradient was verified within the sample holder, in some irradiation positions of the IEA-R1 reactor at IPEN/CNEN, Sao Paulo. The fission track dating method considers only the thermal neutron fission tracks, to subtract the other contributions sample irradiations with a cadmium cover was performed. The neutron flux cadmium influence was studied. (author)

  5. Compensation Methods for Non-uniform and Incomplete Data Sampling in High Resolution PET with Multiple Scintillation Crystal Layers

    International Nuclear Information System (INIS)

    Lee, Jae Sung; Kim, Soo Mee; Lee, Dong Soo; Hong, Jong Hong; Sim, Kwang Souk; Rhee, June Tak

    2008-01-01

    To establish the methods for sinogram formation and correction in order to appropriately apply the filtered backprojection (FBP) reconstruction algorithm to the data acquired using PET scanner with multiple scintillation crystal layers. Formation for raw PET data storage and conversion methods from listmode data to histogram and sinogram were optimized. To solve the various problems occurred while the raw histogram was converted into sinogram, optimal sampling strategy and sampling efficiency correction method were investigated. Gap compensation methods that is unique in this system were also investigated. All the sinogram data were reconstructed using 2D filtered backprojection algorithm and compared to estimate the improvements by the correction algorithms. Optimal radial sampling interval and number of angular samples in terms of the sampling theorem and sampling efficiency correction algorithm were pitch/2 and 120, respectively. By applying the sampling efficiency correction and gap compensation, artifacts and background noise on the reconstructed image could be reduced. Conversion method from the histogram to sinogram was investigated for the FBP reconstruction of data acquired using multiple scintillation crystal layers. This method will be useful for the fast 2D reconstruction of multiple crystal layer PET data

  6. Highly uniform resistive switching properties of amorphous InGaZnO thin films prepared by a low temperature photochemical solution deposition method.

    Science.gov (United States)

    Hu, Wei; Zou, Lilan; Chen, Xinman; Qin, Ni; Li, Shuwei; Bao, Dinghua

    2014-04-09

    We report on highly uniform resistive switching properties of amorphous InGaZnO (a-IGZO) thin films. The thin films were fabricated by a low temperature photochemical solution deposition method, a simple process combining chemical solution deposition and ultraviolet (UV) irradiation treatment. The a-IGZO based resistive switching devices exhibit long retention, good endurance, uniform switching voltages, and stable distribution of low and high resistance states. Electrical conduction mechanisms were also discussed on the basis of the current-voltage characteristics and their temperature dependence. The excellent resistive switching properties can be attributed to the reduction of organic- and hydrogen-based elements and the formation of enhanced metal-oxide bonding and metal-hydroxide bonding networks by hydrogen bonding due to UV irradiation, based on Fourier-transform-infrared spectroscopy, X-ray photoelectron spectroscopy, and Field emission scanning electron microscopy analysis of the thin films. This study suggests that a-IGZO thin films have potential applications in resistive random access memory and the low temperature photochemical solution deposition method can find the opportunity for further achieving system on panel applications if the a-IGZO resistive switching cells were integrated with a-IGZO thin film transistors.

  7. Uniform hollow Fe3O4 spheres prepared by template-free solvothermal method as anode material for lithium-ion batteries

    International Nuclear Information System (INIS)

    Zhang Jingjing; Yao Yu; Huang Tao; Yu Aishui

    2012-01-01

    Graphical abstract: Unique hollow Fe 3 O 4 spheres assembled by Fe 3 O 4 nanoparticles prepared by a simple template-free solvothermal reaction are tested as anode material for lithium-ion batteries. The results show that the material delivers reversible specific capacities of 870 mA h g −1 even after 50 cycles at 100 mA g −1 and 836 mA h g −1 at 500 mA g −1 . The excellent electrochemical performance can be attributed to their hollow nanostructure and excellent structural stability. Highlights: ► Uniform hollow Fe 3 O 4 spheres were prepared by a template-free solvothermal method. ► The hollow Fe 3 O 4 spheres have the capacity of 870 mA h g −1 at 50th cycle. ► The specific capacity can be well maintained at a large current density. ► The hollow Fe 3 O 4 spheres exhibit enhanced rate capability. ► Electrochemical performance of hollow Fe 3 O 4 spheres is better than Fe 3 O 4 powders. - Abstract: Unique hollow Fe 3 O 4 spheres are prepared by a simple template-free solvothermal reaction. In the reaction, ethylene glycol (EG) and polyvinylpyrrolidone (PVP) serve as the reducing agent and surface stabilizer, respectively. NH 4 Ac plays the role of the structure-directing agent, which combines with the Ostwald ripening process, resulting in the favored formation of hollow structures. The morphologies and structures are characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The hollow Fe 3 O 4 spheres exhibit excellent cycling and rate performance as anode material for lithium-ion batteries, delivering reversible specific capacities of 870 mA h g −1 even after 50 cycles at 100 mA g −1 and 836 mA h g −1 at 500 mA g −1 . The excellent electrochemical performance can be attributed to their hollow nanostructure and excellent structural stability.

  8. Wafer scale imprint uniformity evaluated by LSPR spectroscopy: a high volume characterization method for nanometer scale structures

    DEFF Research Database (Denmark)

    Jeppesen, Claus; Lindstedt, Daniel Nilsson; Vig, Asger Laurberg

    2012-01-01

    numerical simulations of imprinted structures characterized by atomic force microscopy. There is a fair agreement between the two methods and the simulations enable the translation of optical spectra to critical dimensions of the physical structures, a concept known from scatterometry. The results...

  9. Deposition of very thin uniform indium sulfide layers over metallic nano-rods by the Spray-Ion Layer Gas Reaction method

    Energy Technology Data Exchange (ETDEWEB)

    Genduso, G. [Dipartimento di Ingegneria Chimica, Gestionale, Informatica, Meccanica, Università di Palermo, Viale delle Scienze, 90100 Palermo (Italy); Institut for Heterogeneous Material Systems, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, D-14109 Berlin (Germany); Inguanta, R.; Sunseri, C.; Piazza, S. [Dipartimento di Ingegneria Chimica, Gestionale, Informatica, Meccanica, Università di Palermo, Viale delle Scienze, 90100 Palermo (Italy); Kelch, C.; Sáez-Araoz, R. [Institut for Heterogeneous Material Systems, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, D-14109 Berlin (Germany); Zykov, A. [Institut for Heterogeneous Material Systems, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, D-14109 Berlin (Germany); present address: Institut für Physik, Humboldt-Universität zu Berlin, Newtonstr. 15,12489 Berlin (Germany); Fischer, Ch.-H., E-mail: fischer@helmholtz-berlin.de [Institut for Heterogeneous Material Systems, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, D-14109 Berlin (Germany); second affiliation: Free University Berlin, Chemistry Institute, Takustr. 3, D-14195 Berlin (Germany)

    2013-12-02

    Very thin and uniform layers of indium sulfide were deposited on nickel nano-rods using the sequential and cyclical Spray-ILGAR® (Ion Layer Gas Reaction) technique. Substrates were fabricated by electrodeposition of Ni within the pores of polycarbonate membranes and subsequent chemical dissolution of the template. With respect to the depositions on flat substrates, experimental conditions were modified and optimized for the present geometry. Our results show that nano-rods up to a length of 10 μm were covered uniformly along their full length and with an almost constant film growth rate, thus allowing a good control of the coating thickness; the effect of the deposition temperature was also investigated. However, for high numbers of process steps, i.e. thickness, the films became uneven and crusty, especially at higher temperature, mainly owing to the simultaneous side reaction of the metallic Ni forming nickel sulfide at the surface of the rods. However, such a problem occurs only in the case of reactive nano-rod materials, such as less noble metals. It could be strongly reduced by doubling the spray step duration and thereby sealing the metallic surface before the process step of the sulfurization. Thus, quite smooth, about 100 nm thick coatings could be obtained. - Highlights: • Ni nano-rod substrates were grown within polycarbonate membranes. • We can coat nano-rods uniformly by the Ion Layer Gas Reaction method. • As a model we deposited up to about 100 nm In{sub 2}S{sub 3} on Ni nanorods (250 nm × 10 μm). • Element mapping at insulated rods showed homogenous coating over the full length. • Parameter optimization reduced effectively the Ni sulfide formation.

  10. Self-test Monte Carlo method

    International Nuclear Information System (INIS)

    Ohta, Shigemi

    1996-01-01

    The Self-Test Monte Carlo (STMC) method resolves the main problems in using algebraic pseudo-random numbers for Monte Carlo (MC) calculations: that they can interfere with MC algorithms and lead to erroneous results, and that such an error often cannot be detected without known exact solution. STMC is based on good randomness of about 10 10 bits available from physical noise or transcendental numbers like π = 3.14---. Various bit modifiers are available to get more bits for applications that demands more than 10 10 random bits such as lattice quantum chromodynamics (QCD). These modifiers are designed so that a) each of them gives a bit sequence comparable in randomness as the original if used separately from each other, and b) their mutual interference when used jointly in a single MC calculation is adjustable. Intermediate data of the MC calculation itself are used to quantitatively test and adjust the mutual interference of the modifiers in respect of the MC algorithm. STMC is free of systematic error and gives reliable statistical error. Also it can be easily implemented on vector and parallel supercomputers. (author)

  11. Uniform stable conformal convolutional perfectly matched layer for enlarged cell technique conformal finite-difference time-domain method

    International Nuclear Information System (INIS)

    Wang Yue; Wang Jian-Guo; Chen Zai-Gao

    2015-01-01

    Based on conformal construction of physical model in a three-dimensional Cartesian grid, an integral-based conformal convolutional perfectly matched layer (CPML) is given for solving the truncation problem of the open port when the enlarged cell technique conformal finite-difference time-domain (ECT-CFDTD) method is used to simulate the wave propagation inside a perfect electric conductor (PEC) waveguide. The algorithm has the same numerical stability as the ECT-CFDTD method. For the long-time propagation problems of an evanescent wave in a waveguide, several numerical simulations are performed to analyze the reflection error by sweeping the constitutive parameters of the integral-based conformal CPML. Our numerical results show that the integral-based conformal CPML can be used to efficiently truncate the open port of the waveguide. (paper)

  12. Radiation heat transfer model using Monte Carlo ray tracing method on hierarchical ortho-Cartesian meshes and non-uniform rational basis spline surfaces for description of boundaries

    Directory of Open Access Journals (Sweden)

    Kuczyński Paweł

    2014-06-01

    Full Text Available The paper deals with a solution of radiation heat transfer problems in enclosures filled with nonparticipating medium using ray tracing on hierarchical ortho-Cartesian meshes. The idea behind the approach is that radiative heat transfer problems can be solved on much coarser grids than their counterparts from computational fluid dynamics (CFD. The resulting code is designed as an add-on to OpenFOAM, an open-source CFD program. Ortho-Cartesian mesh involving boundary elements is created based upon CFD mesh. Parametric non-uniform rational basis spline (NURBS surfaces are used to define boundaries of the enclosure, allowing for dealing with domains of complex shapes. Algorithm for determining random, uniformly distributed locations of rays leaving NURBS surfaces is described. The paper presents results of test cases assuming gray diffusive walls. In the current version of the model the radiation is not absorbed within gases. However, the ultimate aim of the work is to upgrade the functionality of the model, to problems in absorbing, emitting and scattering medium projecting iteratively the results of radiative analysis on CFD mesh and CFD solution on radiative mesh.

  13. Controlled Acoustic Bass System (CABS) A Method to Achieve Uniform Sound Field Distribution at Low Frequencies in Rectangular Rooms

    DEFF Research Database (Denmark)

    Celestinos, Adrian; Nielsen, Sofus Birkedal

    2008-01-01

    The sound field produced by loudspeakers at low frequencies in small- and medium-size rectangular listening rooms is highly nonuniform due to the multiple reflections and diffractions of sound on the walls and different objects in the room. A new method, called controlled acoustic bass system (CA......-frequency range. CABS has been simulated and measured in two different standard listening rooms with satisfactory results....

  14. UOBPRM: A uniformly distributed obstacle-based PRM

    KAUST Repository

    Yeh, Hsin-Yi

    2012-10-01

    This paper presents a new sampling method for motion planning that can generate configurations more uniformly distributed on C-obstacle surfaces than prior approaches. Here, roadmap nodes are generated from the intersections between C-obstacles and a set of uniformly distributed fixed-length segments in C-space. The results show that this new sampling method yields samples that are more uniformly distributed than previous obstacle-based methods such as OBPRM, Gaussian sampling, and Bridge test sampling. UOBPRM is shown to have nodes more uniformly distributed near C-obstacle surfaces and also requires the fewest nodes and edges to solve challenging motion planning problems with varying narrow passages. © 2012 IEEE.

  15. Assessment of uniformity and signal-to-noise ratio in radiological image intensifier TV systems

    International Nuclear Information System (INIS)

    Malone, J.F.; O'Connor, M.K.; Maher, K.P.

    1985-01-01

    A method of measuring the uniformity of radiological Image Intensifier-TV systems is described. Large non-uniformities were observed in the systems tested. A method of estimating the Signal-to-Noise Ratio in such systems is also presented and applied to characterise the effectiveness of the noise reduction techniques used in digital fluoroscopy. (author)

  16. Contact behavior analysis of elastomeric x-ring under uniform squeeze rate and internal pressure before and after forcing-out using the photoelastic experimental hybrid method

    Energy Technology Data Exchange (ETDEWEB)

    Bernard, Alunda Ouma [Dedan Kimathi University of Technology, Nyeri (Kenya); Hawong, Jai Sug; Dong, Bai [Yeungnam University, Gyeongsan (Korea, Republic of); Shin, Dong Chul [Koje College, Geoje (Korea, Republic of)

    2015-05-15

    Many different types of elastomeric rings have been developed to suit various needs in industry. The X-ring was introduced as a result of the limitations of O-rings that twist, especially during dynamic application. A better understanding of the behavior and the stress distribution of the X-ring under a uniform squeeze rate and internal pressure is needed. We analyzed the contact stresses and internal stresses developed in an X-ring before and after forcing-out by using the photoelastic experimental hybrid method, ascertained the packing ability of an X-ring, and studied the failure criterion of an X-ring under uniform squeeze rate and internal pressure. Forcing-out in the X-ring occurred when the internal pressure was 3.92 MPa. After forcing-out, at an internal pressure of 5.88 MPa, the two lobes on the upper contact surface merged one contact side of the upper side immensely. Even after extrusion of the X-ring, the X-ring can be used to effectively contain the fluid. This is because the effects of extrusion on the X-ring affected the stress distribution of only two lobes close to the assembly gap and the two lobes are merge into one lobe. In addition, our experimental results show that the maximum shear failure criterion is suitable for the prediction of failure in X-ring seals.

  17. A three-dimensional numerical study on dynamics behavior of a rising vapor bubble in uniformly superheated liquid by lattice Boltzmann method

    International Nuclear Information System (INIS)

    Sun, Tao; Sun, Jiangang; Ang, Xueye; Li, Shanshan; Su, Xin

    2016-01-01

    Highlights: • Dynamics of vapor bubble in uniformly superheated liquid is studied by a 3D LBM. • The growth rate reaches a maximum value and then decrease until a certain value. • The vapor bubble will take place a larger deformation at high ratio of Re/Eo. • The bubble wake has a great influence on motion and deformation of vapor bubble. • Ratio of Re/Eo has an important influence on evolution of temperature field. - Abstract: In this paper, dynamics behaviors of a rising vapor bubble in uniformly superheated liquid are firstly studied by a hybrid three-dimensional lattice Boltzmann model. In order to validate this model, two test cases regarding bubble rising in an isothermal system and vapor bubble growth in a superheated liquid are performed, respectively. The test results are consistent with existing results and indicate the feasibility of the hybrid model. The hybrid model is further applied to simulate growth and deformation of a rising vapor bubble in different physical conditions. Some physical parameters of vapor bubble such as equivalent diameter and growth rate are evaluated accurately by three-dimensional simulations. It is found that the growth rate of vapor bubble changes with time and temperature gradient. It reaches a maximum value at the initial stage and then decrease until a certain value. The growth and deformation of vapor bubble at different ratios of Re/Eo are discussed. The numerical results show the vapor bubble will take place a larger deformation at high ratio of Re/Eo at the middle and final stages. In addition, the hybrid model is also applied to predict the evolution of flow and temperature fields. The bubble wake has a great influence on the motion and deformation of vapor bubble during rising process. As far as the temperature field is concerned, a ratio of Re/Eo has an important influence on heat transfer and evolution of temperature field.

  18. Quasi-uniform Space

    Directory of Open Access Journals (Sweden)

    Coghetto Roland

    2016-09-01

    Full Text Available In this article, using mostly Pervin [9], Kunzi [6], [8], [7], Williams [11] and Bourbaki [3] works, we formalize in Mizar [2] the notions of quasiuniform space, semi-uniform space and locally uniform space.

  19. Quasi-uniform Space

    OpenAIRE

    Coghetto Roland

    2016-01-01

    In this article, using mostly Pervin [9], Kunzi [6], [8], [7], Williams [11] and Bourbaki [3] works, we formalize in Mizar [2] the notions of quasiuniform space, semi-uniform space and locally uniform space.

  20. Unique battery with an active membrane separator having uniform physico-chemically functionalized ion channels and a method making the same

    Science.gov (United States)

    Gerald, II, Rex E.; Ruscic, Katarina J [Chicago, IL; Sears, Devin N [Spruce Grove, CA; Smith, Luis J [Natick, MA; Klingler, Robert J [Glenview, IL; Rathke, Jerome W [Homer Glen, IL

    2012-02-21

    The invention relates to a unique battery having an active, porous membrane and method of making the same. More specifically the invention relates to a sealed battery system having a porous, metal oxide membrane with uniform, physicochemically functionalized ion channels capable of adjustable ionic interaction. The physicochemically-active porous membrane purports dual functions: an electronic insulator (separator) and a unidirectional ion-transporter (electrolyte). The electrochemical cell membrane is activated for the transport of ions by contiguous ion coordination sites on the interior two-dimensional surfaces of the trans-membrane unidirectional pores. The membrane material is designed to have physicochemical interaction with ions. Control of the extent of the interactions between the ions and the interior pore walls of the membrane and other materials, chemicals, or structures contained within the pores provides adjustability of the ionic conductivity of the membrane.

  1. New method of analyzing well tests in fractured wells using sandface pressure and rate data

    Energy Technology Data Exchange (ETDEWEB)

    Osman, M.; Almehaideb, R.; Abou-Kassem, J. [U.A.E. University, Al-Ain (United Arab Emirates)

    1998-05-01

    Analysis of variable flow rate tests has been of special interest recently because in many cases it is impractical to keep a flow rate constant long enough to perform a drawdown test. Further, in many other drawdown and buildup tests, the early data were influenced by wellbore storage effects, and the duration of these effects could be quite long for low-permeability reservoirs. This paper presents a mathematical model which describes drawdown and buildup tests in hydraulically fractured wells. This new method uses a specialized plot approach to analyze the linear flow data and combines it with the superposition of constant-rate solution method for the analysis of psuedoradial flow data. It does not require prior knowledge of the fracture type (uniform-flux or infinite-conductivity); in fact it predicts the fracture type. This method is useful for the analysis of simultaneously measured downhole pressure and sandface rate data. 12 refs., 11 figs., 3 tabs.

  2. School Uniforms Redux.

    Science.gov (United States)

    Dowling-Sendor, Benjamin

    2002-01-01

    Reviews a recent decision in "Littlefield" by the 5th Circuit upholding a school uniform policy. Advises board member who wish to adopt a school uniform policy to solicit input from parents and students, research the experiences of other school districts with uniform policies, and articulate the interests they wish to promote through uniform…

  3. Do School Uniforms Fit?

    Science.gov (United States)

    White, Kerry A.

    2000-01-01

    In 1994, Long Beach (California) Unified School District began requiring uniforms in all elementary and middle schools. Now, half of all urban school systems and many suburban schools have uniform policies. Research on uniforms' effectiveness is mixed. Tightened dress codes may be just as effective and less litigious. (MLH)

  4. Mandatory School Uniforms.

    Science.gov (United States)

    Cohn, Carl A.

    1996-01-01

    Shortly after implementing a mandatory school uniform policy, the Long Beach (California) Public Schools can boast 99% compliance and a substantial reduction in school crime. The uniforms can't be confused with gang colors, save parents money, and help identify outsiders. A sidebar lists ingredients for a mandatory uniform policy. (MLH)

  5. Solar panel thermal cycling testing by solar simulation and infrared radiation methods

    Science.gov (United States)

    Nuss, H. E.

    1980-01-01

    For the solar panels of the European Space Agency (ESA) satellites OTS/MAROTS and ECS/MARECS the thermal cycling tests were performed by using solar simulation methods. The performance data of two different solar simulators used and the thermal test results are described. The solar simulation thermal cycling tests for the ECS/MARECS solar panels were carried out with the aid of a rotatable multipanel test rig by which simultaneous testing of three solar panels was possible. As an alternative thermal test method, the capability of an infrared radiation method was studied and infrared simulation tests for the ultralight panel and the INTELSAT 5 solar panels were performed. The setup and the characteristics of the infrared radiation unit using a quartz lamp array of approx. 15 sq and LN2-cooled shutter and the thermal test results are presented. The irradiation uniformity, the solar panel temperature distribution, temperature changing rates for both test methods are compared. Results indicate the infrared simulation is an effective solar panel thermal testing method.

  6. A direct method to solve optimal knots of B-spline curves: An application for non-uniform B-spline curves fitting.

    Directory of Open Access Journals (Sweden)

    Van Than Dung

    Full Text Available B-spline functions are widely used in many industrial applications such as computer graphic representations, computer aided design, computer aided manufacturing, computer numerical control, etc. Recently, there exist some demands, e.g. in reverse engineering (RE area, to employ B-spline curves for non-trivial cases that include curves with discontinuous points, cusps or turning points from the sampled data. The most challenging task in these cases is in the identification of the number of knots and their respective locations in non-uniform space in the most efficient computational cost. This paper presents a new strategy for fitting any forms of curve by B-spline functions via local algorithm. A new two-step method for fast knot calculation is proposed. In the first step, the data is split using a bisecting method with predetermined allowable error to obtain coarse knots. Secondly, the knots are optimized, for both locations and continuity levels, by employing a non-linear least squares technique. The B-spline function is, therefore, obtained by solving the ordinary least squares problem. The performance of the proposed method is validated by using various numerical experimental data, with and without simulated noise, which were generated by a B-spline function and deterministic parametric functions. This paper also discusses the benchmarking of the proposed method to the existing methods in literature. The proposed method is shown to be able to reconstruct B-spline functions from sampled data within acceptable tolerance. It is also shown that, the proposed method can be applied for fitting any types of curves ranging from smooth ones to discontinuous ones. In addition, the method does not require excessive computational cost, which allows it to be used in automatic reverse engineering applications.

  7. Neuropsychological Testing in Pathologically Verified Alzheimer Disease and Frontotemporal Dementia: How Well Do the Uniform Data Set Measures Differentiate Between Diseases?

    Science.gov (United States)

    Ritter, Aaron R; Leger, Gabriel C; Miller, Justin B; Banks, Sarah J

    2017-01-01

    Differences in cognition between frontotemporal dementia (FTD) and Alzheimer disease (AD) are well described in clinical cohorts, but have rarely been confirmed in studies with pathologic verification. For emerging therapeutics to succeed, determining underlying pathology early in the disease course is increasingly important. Neuropsychological evaluation is an important component of the diagnostic workup for AD and FTD. Patients with FTD are thought to have greater deficits in language and executive function while patients with AD are more likely to have deficits in memory. To determine if performance on initial cognitive testing can reliably distinguish between patients with frontotemporal lobar degeneration (FTLD) and AD neuropathology. In addition, are there other factors of the neuropsychological assessment that can be used to enhance the accuracy of underlying pathology? Using a logistic regression we retrospectively compared neurocognitive performance on initial evaluation of 106 patients with pathologically verified FTLD (pvFTLD), with 558 pathologically verified AD (pvAD) patients from the National Alzheimer's Coordinating Center using data from the Uniform Data Set (UDS) and the neuropathology data set. As expected, pvFTLD patients were younger, demonstrated better memory performance, and had more neuropsychiatric symptoms than pvAD patients. Other results were less predictable: pvFTLD patients performed better on one test of executive function (trail making test part B) but worse on another (digit span backward). Performance on language testing did not strongly distinguish the 2 groups. To determine what factors led to a misdiagnosis of AD in patients with FTLD, we further analyzed a small group of pvFTLD patients. These patients demonstrated older age and lower Neuropsychiatric Inventory Questionnaire counts compared with accurately diagnosed cases. Other than memory, numerical scores of neurocognitive performance on the UDS are of limited value in

  8. Development of a NIR-based blend uniformity method for a drug product containing multiple structurally similar actives by using the quality by design principles.

    Science.gov (United States)

    Lin, Yiqing; Li, Weiyong; Xu, Jin; Boulas, Pierre

    2015-07-05

    The aim of this study is to develop an at-line near infrared (NIR) method for the rapid and simultaneous determination of four structurally similar active pharmaceutical ingredients (APIs) in powder blends intended for the manufacturing of tablets. Two of the four APIs in the formula are present in relatively small amounts, one at 0.95% and the other at 0.57%. Such small amounts in addition to the similarity in structures add significant complexity to the blend uniformity analysis. The NIR method is developed using spectra from six laboratory-created calibration samples augmented by a small set of spectra from a large-scale blending sample. Applying the quality by design (QbD) principles, the calibration design included concentration variations of the four APIs and a main excipient, microcrystalline cellulose. A bench-top FT-NIR instrument was used to acquire the spectra. The obtained NIR spectra were analyzed by applying principal component analysis (PCA) before calibration model development. Score patterns from the PCA were analyzed to reveal relationship between latent variables and concentration variations of the APIs. In calibration model development, both PLS-1 and PLS-2 models were created and evaluated for their effectiveness in predicting API concentrations in the blending samples. The final NIR method shows satisfactory specificity and accuracy. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. 40 CFR 63.1161 - Performance testing and test methods.

    Science.gov (United States)

    2010-07-01

    ..., “Determination of Hydrogen Halide and Halogen Emissions from Stationary Sources—Isokinetic Method,” to determine... shall be 60 minutes and the minimum sample volume 0.85 dry standard cubic meters (30 dry standard cubic...(mg/dscm) is concentration in milligrams per dry standard cubic meter as calculated by the procedure...

  10. Lubricant Test Methods for Sheet Metal Forming

    DEFF Research Database (Denmark)

    Bay, Niels; Olsson, David Dam; Andreasen, Jan Lasson

    2008-01-01

    appearing in different sheet forming operations such as stretch forming, deep drawing, ironing and punching. The laboratory tests have been especially designed to model the conditions in industrial production. Application of the tests for evaluating new lubricants before introducing them in production has......Sheet metal forming of tribologically difficult materials such as stainless steel, Al-alloys and Ti-alloys or forming in tribologically difficult operations like ironing, punching or deep drawing of thick plate requires often use of environmentally hazardous lubricants such as chlorinated paraffin...... oils in order to avoid galling. The present paper describes a systematic research in the development of new, environmentally harmless lubricants focusing on the lubricant testing aspects. A system of laboratory tests has been developed to study the lubricant performance under the very varied conditions...

  11. Effects of uniformities of deposition of respirable particles on filters on determining their quartz contents by using the direct on-filter X-ray diffraction (DOF XRD) method.

    Science.gov (United States)

    Chen, Ching-Hwa; Tsaia, Perng-Jy; Lai, Chane-Yu; Peng, Ya-Lian; Soo, Jhy-Charm; Chen, Cheng-Yao; Shih, Tung-Sheng

    2010-04-15

    In this study, field samplings were conducted in three workplaces of a foundry plant, including the molding, demolding, and bead blasting, respectively. Three respirable aerosol samplers (including a 25-mm aluminum cyclone, nylon cyclone, and IOSH cyclone) were used side-by-side to collect samples from each selected workplace. For each collected sample, the uniformity of the deposition of respirable dusts on the filter was measured and its free silica content was determined by both the DOF XRD method and NIOSH 7500 XRD method (i.e., the reference method). A same trend in measured uniformities can be found in all selected workplaces: 25-mm aluminum cyclone>nylon cyclone>IOSH cyclone. Even for samples collected by the sampler with the highest uniformity (i.e., 25-mm aluminum cyclone), the use of the DOF XRD method would lead to the measured free silica concentrations 1.15-2.89 times in magnitude higher than that of the reference method. A new filter holder should be developed with the minimum uniformity comparable to that of NIOSH 7500 XRD method (=0.78) in the future. The use of conversion factors for correcting quartz concentrations obtained from the DOF XRD method based on the measured uniformities could be suitable for the foundry industry at this stage. 2009 Elsevier B.V. All rights reserved.

  12. Effects of uniformities of deposition of respirable particles on filters on determining their quartz contents by using the direct on-filter X-ray diffraction (DOF XRD) method

    International Nuclear Information System (INIS)

    Chen, Ching-Hwa; Tsaia, Perng-Jy; Lai, Chane-Yu; Peng, Ya-Lian; Soo, Jhy-Charm; Chen, Cheng-Yao; Shih, Tung-Sheng

    2010-01-01

    In this study, field samplings were conducted in three workplaces of a foundry plant, including the molding, demolding, and bead blasting, respectively. Three respirable aerosol samplers (including a 25-mm aluminum cyclone, nylon cyclone, and IOSH cyclone) were used side-by-side to collect samples from each selected workplace. For each collected sample, the uniformity of the deposition of respirable dusts on the filter was measured and its free silica content was determined by both the DOF XRD method and NIOSH 7500 XRD method (i.e., the reference method). A same trend in measured uniformities can be found in all selected workplaces: 25-mm aluminum cyclone > nylon cyclone > IOSH cyclone. Even for samples collected by the sampler with the highest uniformity (i.e., 25-mm aluminum cyclone), the use of the DOF XRD method would lead to the measured free silica concentrations 1.15-2.89 times in magnitude higher than that of the reference method. A new filter holder should be developed with the minimum uniformity comparable to that of NIOSH 7500 XRD method (=0.78) in the future. The use of conversion factors for correcting quartz concentrations obtained from the DOF XRD method based on the measured uniformities could be suitable for the foundry industry at this stage.

  13. Quenching Combustible Dust Mixtures Using Electric Particulate Suspensions (EPS): A New Testing Method For Microgravity

    Science.gov (United States)

    Colver, Gerald M.; Greene, Nathanael; Shoemaker, David; Xu, Hua

    2003-01-01

    The Electric Particulate Suspension (EPS) is a combustion ignition system being developed at Iowa State University for evaluating quenching effects of powders in microgravity (quenching distance, ignition energy, flammability limits). Because of the high cloud uniformity possible and its simplicity, the EPS method has potential for "benchmark" design of quenching flames that would provide NASA and the scientific community with a new fire standard. Microgravity is expected to increase suspension uniformity even further and extend combustion testing to higher concentrations (rich fuel limit) than is possible at normal gravity. Two new combustion parameters are being investigated with this new method: (1) the particle velocity distribution and (2) particle-oxidant slip velocity. Both walls and (inert) particles can be tested as quenching media. The EPS method supports combustion modeling by providing accurate measurement of flame-quenching distance as a parameter in laminar flame theory as it closely relates to characteristic flame thickness and flame structure. Because of its design simplicity, EPS is suitable for testing on the International Space Station (ISS). Laser scans showing stratification effects at 1-g have been studied for different materials, aluminum, glass, and copper. PTV/PIV and a leak hole sampling rig give particle velocity distribution with particle slip velocity evaluated using LDA. Sample quenching and ignition energy curves are given for aluminum powder. Testing is planned for the KC-135 and NASA s two second drop tower. Only 1-g ground-based data have been reported to date.

  14. Standard test method for determination of "microwave safe for reheating" for ceramicware

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This test method determines the suitability of ceramicware for use in microwave re-heating applications. Microwave ovens are mainly used for reheating and defrosting frozen foods. Severe thermal conditions can occur while reheating foods. Typical reheating of foods requires one to five min. in the microwave at the highest power settings. Longer periods than five minutes are considered cooking. Cooking test methods and standards are not addressed in this test method. Most ceramicware is minimally absorbing of the microwave energy and will not heat up significantly. Unfortunately there are some products that absorb microwave energy to a greater extent and can become very hot in the microwave and pose a serious hazard. Additionally, the nature of microwave heating introduces radiation in a non-uniform manner producing temperature differentials in the food being cooked as well as the ceramic container holding it. The differential may become great enough to thermal shock the ware and create dangerous condition...

  15. Leak test method and test device for iodine filter

    International Nuclear Information System (INIS)

    Fukasawa, Tetsuo; Funabashi, Kiyomi; Miura, Noboru; Miura, Eiichi.

    1995-01-01

    An air introduction device which can change a humidity is disposed upstream of an iodine filter to be tested, and a humidity measuring device is disposed downstream of the iodine filter respectively. At first, dried air reduced with humidity is flown from the air introduction device to the iodine filter, to remove moisture content from an iodine adsorber in the iodine filter. Next, air at an increased humidity is supplied to the iodine filter. The difference between the time starting the supply of the highly humid air and the time detecting the high humidity at the humidity measuring device is measured. When the time difference is smaller than the time difference measured previously in a normal iodine filter, it shows the presence of leak in the iodine filter to be tested. With such procedures, leakage in the iodine filter which removes radioactive iodine from off-gases discharged from the radioactive material handling facilities can be detected easily by using water (steams), namely, a naturally present material. (I.N.)

  16. 40 CFR Appendix A to Part 63 - Test Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods A Appendix A to Part 63... to Part 63—Test Methods Method 301—Field Validation of Pollutant Measurement Methods from Various Waste Media 1. Applicability and principle 1.1Applicability. This method, as specified in the applicable...

  17. Methods and models for the construction of weakly parallel tests

    NARCIS (Netherlands)

    Adema, J.J.; Adema, Jos J.

    1990-01-01

    Methods are proposed for the construction of weakly parallel tests, that is, tests with the same test information function. A mathematical programing model for constructing tests with a prespecified test information function and a heuristic for assigning items to tests such that their information

  18. Development of standard testing methods for nuclear-waste forms

    International Nuclear Information System (INIS)

    Mendel, J.E.; Nelson, R.D.

    1981-11-01

    Standard test methods for waste package component development and design, safety analyses, and licensing are being developed for the Nuclear Waste Materials Handbook. This paper describes mainly the testing methods for obtaining waste form materials data

  19. Antimicrobial Testing Methods & Procedures Developed by EPA's Microbiology Laboratory

    Science.gov (United States)

    We develop antimicrobial testing methods and standard operating procedures to measure the effectiveness of hard surface disinfectants against a variety of microorganisms. Find methods and procedures for antimicrobial testing.

  20. Synthesis of uniform nano-structured lead oxide by sonochemical method and its application as cathode and anode of lead-acid batteries

    International Nuclear Information System (INIS)

    Karami, Hassan; Karimi, Mohammad Ali; Haghdar, Saeed

    2008-01-01

    This paper discusses the results of a research aimed at investigating the synthesis of nano-structured lead oxide through reaction of lead nitrate solution and sodium carbonate solution by the sonochemical method. At the first, lead carbonate was obtained in a synthesized solution and then, after filtration, it was calcinated at the temperature of 320 deg. C so that nano-structured lead oxide can be produced. The effects of different parameters on particle size and morphology of final lead oxide powder were optimized by a 'one at a time' method. The prepared lead oxide powder was characterized by scanning electron microscopy (SEM), transmission electron spectroscopy (TEM) and X-ray diffraction (XRD). Under optimum conditions, uniformed and homogeneous nano-structured lead oxide powder with more spongy morphology and particle size of 20-40 nm was obtained. The synthesized lead oxide, as anode and cathode of lead-acid batteries, showed an excellent discharge capacity (140 mA h/g)

  1. Multi-frequency eddy current testing method

    International Nuclear Information System (INIS)

    Levy, R.; Gallet, G.

    1980-01-01

    Monitoring by multi-frequency eddy currents has been used since 1975 in French nuclear stations; this method applies perfectly to examinations in non-irradiated surroundings. The restrictions connected with operations in controlled zones (radioactivity) have led to the development of a delayed analysis device which in no way changes the principle of the method, but allows greater flexibility of use by reducing the volume of equipment needed and by limiting the intervention of personnel to a strict minimum [fr

  2. Review of Test Theory and Methods.

    Science.gov (United States)

    1981-01-01

    literature, although some books , technical reports, and unpub- lished literature have been included where relevant. The focus of the review is on practical...1977) and Abu-Sayf (1977) developed new versions of formula scores, and Molenaar (1977) took a Bayesian approach to correcting for random guessing. The...Snow’s (1977) book on aptitude and instructional methods is a landmark review of the research on the interaction between instructional methods and

  3. 16 CFR 1513.4 - Test methods.

    Science.gov (United States)

    2010-01-01

    ... Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS..., gradually apply a 33-lbf (147-N) force in a direction perpendicular to the plane of the large end of the... Figure 2 of this part into the portion of the boundary to be tested, with the plane of the template in...

  4. 16 CFR 1213.4 - Test methods.

    Science.gov (United States)

    2010-01-01

    ... Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY... orientation”). Then gradually apply a 33-lbf (147-N) force in a direction perpendicular to the plane of the... Figure 2 of this part into the portion of the boundary of the opening to be tested, with the plane of the...

  5. Comparison of sine dwell and broadband methods for modal testing

    Science.gov (United States)

    Chen, Jay-Chung

    1989-01-01

    The objectives of modal tests for large complex spacecraft structural systems are outlined. The comparison criteria for the modal test methods, namely, the broadband excitation and the sine dwell methods, are established. Using the Galileo spacecraft modal test and the Centaur G Prime upper stage vehicle modal test as examples, the relative advantage or disadvantage of each method is examined. The usefulness or shortcomings of the methods are given from a practical engineering viewpoint.

  6. On sine dwell or broadband methods for modal testing

    Science.gov (United States)

    Chen, Jay-Chung; Wada, Ben K.

    1987-01-01

    For large, complex spacecraft structural systems, the objectives of the modal test are outlined. Based on these objectives, the comparison criteria for the modal test methods, namely, the broadband excitation and the sine dwell methods are established. Using the Galileo spacecraft modal test and the Centaur G Prime upper stage vehicle modal test as examples, the relative advantages or disadvantages of each method are examined. The usefulness or shortcoming of the methods are given from a practicing engineer's view point.

  7. On the assessment of usability testing methods for children

    NARCIS (Netherlands)

    Markopoulos, P.; Bekker, M.M.

    2003-01-01

    The paper motivates the need to acquire methodological knowledge for involving children as test users in usability testing. It introduces a methodological framework for delineating comparative assessments of usability testing methods for children participants. This framework consists in three

  8. 40 CFR Table 3 of Subpart Bbbbbbb... - Test Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods 3 Table 3 of Subpart... 3 Table 3 of Subpart BBBBBBB of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in appendix A to part 60. 2...

  9. 40 CFR Table 3 of Subpart Aaaaaaa... - Test Methods

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods 3 Table 3 of Subpart..., Subpt. AAAAAAA, Table 3 Table 3 of Subpart AAAAAAA of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in...

  10. Atmospheric methods for nuclear test monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Simons, D.J. [Los Alamos National Laboratory, NM (United States)

    1994-12-31

    This report describes two atmomospheric methods for the monitoring and detection of underground nuclear explosions: Near infrasound technique, and ionospheric monitoring. Ground motion from underground explosions cause induced air pressure perturbations. The ionospheric technique utilizes the very strong air pressure pulse which is launched straight up above an underground explosion. When the pressure disturbance reaches the ionosphere, it becomes a 10 % pressure perturbation. Detection involves sending radio waves through the ionosphere with transmitters and recievers on the ground. Radar analysis yields interpretable signals. The near infrasound method detects the signal which is projected into the side lobes of the main signal. Both of the atmospheric methods were utilized on the monitoring of the NPE underground chemical explosion experiment. Results are described.

  11. Chapter 20: Data Center IT Efficiency Measures Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Huang, Robert [The Cadmus Group, Portland, OR (United States); Masanet, Eric [Northwestern Univ., Evanston, IL (United States)

    2017-11-02

    This chapter focuses on IT measures in the data center and examines the techniques and analysis methods used to verify savings that result from improving the efficiency of two specific pieces of IT equipment: servers and data storage.

  12. Reduction Methods for Real-time Simulations in Hybrid Testing

    DEFF Research Database (Denmark)

    Andersen, Sebastian

    2016-01-01

    Hybrid testing constitutes a cost-effective experimental full scale testing method. The method was introduced in the 1960's by Japanese researchers, as an alternative to conventional full scale testing and small scale material testing, such as shake table tests. The principle of the method...... is performed on a glass fibre reinforced polymer composite box girder. The test serves as a pilot test for prospective real-time tests on a wind turbine blade. The Taylor basis is implemented in the test, used to perform the numerical simulations. Despite of a number of introduced errors in the real...... is to divide a structure into a physical substructure and a numerical substructure, and couple these in a test. If the test is conducted in real-time it is referred to as real time hybrid testing. The hybrid testing concept has developed significantly since its introduction in the 1960', both with respect...

  13. Atmospheric methods for nuclear test monitoring

    International Nuclear Information System (INIS)

    Simons, D.J.

    1995-01-01

    The U.S. DOE sponsored research investigating atmospheric infrasound as a means of detecting both atmospheric and underground nuclear tests. Various detection schemes were examined and were found to be effective for different situations. It has been discovered that an enhanced sensitivity is realizable for the very lowest frequency disturbances by detecting the infrasound at the top of the atmosphere using ratio sound techniques. These techniques are compared to more traditional measurement schemes

  14. Prototype development and demonstration for response, emergency staging, communications, uniform management, and evacuation (R.E.S.C.U.M.E.) : technical report on prototype development and field testing of R.E.S.C.U.M.E. applications.

    Science.gov (United States)

    2015-04-01

    This document is the final project technical report for the development and field testing of the Response, Emergency Staging, Communications, Uniform Management, and Evacuation (R.E.S.C.U.M.E.) application bundle, with a focus on the Incident Zone (I...

  15. Systematic evaluation of nondestructive testing methods

    International Nuclear Information System (INIS)

    Segal, Y.; Notea, A.; Segal, E.

    1977-01-01

    The main task of an NDT engineer is to select the best method, considering the cost-benefit value of different available systems and taking into account the special existing constraints. The aim of the paper is to suggest a tool that will enable characterization of measuring systems. The derivation of the characterization parameters and functions has to be general, i.e., suitable for all possible measuring methods, independent of their principle of operation. Quite often the properties measured during the NDT procedure are not the wanted ones, but there must be a correlation between the measured property and the performance of the product. One has to bear in mind that the ultimate choice between systems is not, in practice, just based on the mathematical optimization approach that is presented. Factors like cost-benefit, availability of trained manpower, service, real-time information, weight, volume, etc., may be crucial problems, and they may well dictate the final selection

  16. Chapter 8: Whole-Building Retrofit with Consumption Data Analysis Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Agnew, Ken [DNV GL, Madison, WI (United States); Goldberg, Mimi [DNV GL, Madison, WI (United States)

    2017-11-01

    Whole-building retrofits involve the installation of multiple measures. Whole-building retrofit programs take many forms. With a focus on overall building performance, these programs usually begin with an energy audit to identify cost-effective energy efficiency measures for the home. Measures are then installed, either at no cost to the homeowner or partially paid for by rebates and/or financing. The methods described here may also be applied to evaluation of single-measure retrofit programs. Related methods exist for replace-on-failure programs and for new construction, but are not the subject of this chapter.

  17. Methods and models for the construction of weakly parallel tests

    NARCIS (Netherlands)

    Adema, J.J.; Adema, Jos J.

    1992-01-01

    Several methods are proposed for the construction of weakly parallel tests [i.e., tests with the same test information function (TIF)]. A mathematical programming model that constructs tests containing a prespecified TIF and a heuristic that assigns items to tests with information functions that are

  18. Further comments on the sequential probability ratio testing methods

    Energy Technology Data Exchange (ETDEWEB)

    Kulacsy, K. [Hungarian Academy of Sciences, Budapest (Hungary). Central Research Inst. for Physics

    1997-05-23

    The Bayesian method for belief updating proposed in Racz (1996) is examined. The interpretation of the belief function introduced therein is found, and the method is compared to the classical binary Sequential Probability Ratio Testing method (SPRT). (author).

  19. Standard Test Method for Testing Nonmetallic Seal Materials by Immersion in a Simulated Geothermal Test Fluid

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This test method covers a procedure for a laboratory test for performing an initial evaluation (screening) of nonmetallic seal materials by immersion in a simulated geothermal test fluid. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6 and 11.7.

  20. Reliability of non-destructive testing methods

    International Nuclear Information System (INIS)

    Broekhoven, M.J.G.

    1988-01-01

    This contribution regards the results of an evaluation of the reliability of radiography (X-rays and gamma-rays), manual-, and mechanized/automated ultrasonic examination by generally accepted codes/rules, with respect to detection, characterization and sizing/localization of defects. The evaluation is based on the results of examinations, by a number of teams, of 30 test plates, 30 and 50 mm thickness, containing V,U, X and K-shaped welds each containing several types of imperfections (211) in total) typical for steel arc fusion welding, such as porosity, inclusions, lack of fusion or penetration and cracks. Besides, some results are presented obtained from research on advanced UT-techniques, viz. the time-of-flight-diffraction and flaw-tip deflection technique. (author)

  1. Reliability of non-destructive testing methods

    Energy Technology Data Exchange (ETDEWEB)

    Broekhoven, M J.G. [Ministry of Social Affairs, (Netherlands)

    1988-12-31

    This contribution regards the results of an evaluation of the reliability of radiography (X-rays and gamma-rays), manual-, and mechanized/automated ultrasonic examination by generally accepted codes/rules, with respect to detection, characterization and sizing/localization of defects. The evaluation is based on the results of examinations, by a number of teams, of 30 test plates, 30 and 50 mm thickness, containing V,U, X and K-shaped welds each containing several types of imperfections (211) in total) typical for steel arc fusion welding, such as porosity, inclusions, lack of fusion or penetration and cracks. Besides, some results are presented obtained from research on advanced UT-techniques, viz. the time-of-flight-diffraction and flaw-tip deflection technique. (author). 4 refs.

  2. Test equating, scaling, and linking methods and practices

    CERN Document Server

    Kolen, Michael J

    2014-01-01

    This book provides an introduction to test equating, scaling, and linking, including those concepts and practical issues that are critical for developers and all other testing professionals.  In addition to statistical procedures, successful equating, scaling, and linking involves many aspects of testing, including procedures to develop tests, to administer and score tests, and to interpret scores earned on tests. Test equating methods are used with many standardized tests in education and psychology to ensure that scores from multiple test forms can be used interchangeably.  Test scaling is the process of developing score scales that are used when scores on standardized tests are reported. In test linking, scores from two or more tests are related to one another. Linking has received much recent attention, due largely to investigations of linking similarly named tests from different test publishers or tests constructed for different purposes. In recent years, researchers from the education, psychology, and...

  3. School Uniforms. Research Brief

    Science.gov (United States)

    Walker, Karen

    2007-01-01

    Does clothing make the person or does the person make the clothing? How does what attire a student wears to school affect their academic achievement? In 1996, President Clinton cited examples of school violence and discipline issues that might have been avoided had the students been wearing uniforms ("School uniforms: Prevention or suppression?").…

  4. Games Uniforms Unveiled

    Institute of Scientific and Technical Information of China (English)

    Linda

    2008-01-01

    The uniforms for Beijing Olympics’ workers, technical staff and volunteers have been unveiled to mark the 200-day countdown to the Games. The uniforms feature the key element of the clouds of promise and will be in three colors:red for Beijing Olympic Games Committee staff, blue

  5. Chapter 9: Metering Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy-Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Mort, Dan [ADM Associates, Inc. Sacramento, CA (United States)

    2017-09-01

    Estimated energy savings are calculated as the difference between the energy use during the baseline period and the energy use during the post installation period of the EEM. This chapter describes the physical properties measured in the process of evaluating EEMs and the specific metering methods for several types of measurements. Skill-level requirements and other operating considerations are discussed, including where, when, and how often measurements should be made. The subsequent section identifies metering equipment types and their respective measurement accuracies. This is followed by sections containing suggestions regarding proper data handling procedures and the categorization and definition of several load types.

  6. Chapter 10: Peak Demand and Time-Differentiated Energy Savings Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Stern, Frank [Navigant, Boulder, CO (United States); Spencer, Justin [Navigant, Boulder, CO (United States)

    2017-10-03

    Savings from electric energy efficiency measures and programs are often expressed in terms of annual energy and presented as kilowatt-hours per year (kWh/year). However, for a full assessment of the value of these savings, it is usually necessary to consider the measure or program's impact on peak demand as well as time-differentiated energy savings. This cross-cutting protocol describes methods for estimating the peak demand and time-differentiated energy impacts of measures implemented through energy efficiency programs.

  7. Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Carlson, Stephen [DNV GL, Madison, WI (United States)

    2017-10-04

    This Commercial and Industrial Lighting Controls Evaluation Protocol (the protocol) describes methods to account for energy savings resulting from programmatic installation of lighting control equipment in large populations of commercial, industrial, government, institutional, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. When lighting controls are installed in conjunction with a lighting retrofit project, the lighting control savings must be calculated parametrically with the lighting retrofit project so savings are not double counted.

  8. Chapter 13: Assessing Persistence and Other Evaluation Issues Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Violette, Daniel M. [Navigant, Boulder, CO (United States)

    2017-09-01

    Addressing other evaluation issues that have been raised in the context of energy efficiency programs, this chapter focuses on methods used to address the persistence of energy savings, which is an important input to the benefit/cost analysis of energy efficiency programs and portfolios. In addition to discussing 'persistence' (which refers to the stream of benefits over time from an energy efficiency measure or program), this chapter provides a summary treatment of these issues -Synergies across programs -Rebound -Dual baselines -Errors in variables (the measurement and/or accuracy of input variables to the evaluation).

  9. Chapter 12: Survey Design and Implementation for Estimating Gross Savings Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Baumgartner, Robert [Tetra Tech, Madison, WI (United States)

    2017-10-05

    This chapter presents an overview of best practices for designing and executing survey research to estimate gross energy savings in energy efficiency evaluations. A detailed description of the specific techniques and strategies for designing questions, implementing a survey, and analyzing and reporting the survey procedures and results is beyond the scope of this chapter. So for each topic covered below, readers are encouraged to consult articles and books cited in References, as well as other sources that cover the specific topics in greater depth. This chapter focuses on the use of survey methods to collect data for estimating gross savings from energy efficiency programs.

  10. Chapter 11: Sample Design Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Khawaja, M. Sami [The Cadmus Group, Portland, OR (United States); Rushton, Josh [The Cadmus Group, Portland, OR (United States); Keeling, Josh [The Cadmus Group, Portland, OR (United States)

    2017-09-01

    Evaluating an energy efficiency program requires assessing the total energy and demand saved through all of the energy efficiency measures provided by the program. For large programs, the direct assessment of savings for each participant would be cost-prohibitive. Even if a program is small enough that a full census could be managed, such an undertaking would almost always be an inefficient use of evaluation resources. The bulk of this chapter describes methods for minimizing and quantifying sampling error. Measurement error and regression error are discussed in various contexts in other chapters.

  11. 10 CFR Appendix Z to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of External Power Supplies

    Science.gov (United States)

    2010-01-01

    ... operation when the external power supply is connected to the main electricity supply and the output is (or “all outputs are” for a multiple-voltage external power supply) connected to a load (or “loads” for a... any mechanical, optical, or electronic switches that automatically disconnect mains power from the...

  12. 10 CFR Appendix B to Subpart B of... - Uniform Test Method for Measuring Nominal Full Load Efficiency of Electric Motors

    Science.gov (United States)

    2010-01-01

    ... Efficiency of Electric Motors B Appendix B to Subpart B of Part 431 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY PROGRAM FOR CERTAIN COMMERCIAL AND INDUSTRIAL EQUIPMENT Electric Motors Pt. 431... Efficiency of Electric Motors 1. Definitions. Definitions contained in §§ 431.2 and 431.12 are applicable to...

  13. 10 CFR Appendix E to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Water Heaters

    Science.gov (United States)

    2010-01-01

    ... sensor shall be positioned at the vertical midpoint of each of the six equal volume nodes within the tank. Nodes designate the equal volumes used to evenly partition the total volume of the tank. As much as is....2 °C±2.8 °C). This process shall be repeated until the thermostat controlling the lowest element is...

  14. 10 CFR 431.134 - Uniform test methods for the measurement of energy consumption and water consumption of automatic...

    Science.gov (United States)

    2010-01-01

    ... consumption and water consumption of automatic commercial ice makers. 431.134 Section 431.134 Energy... of energy consumption and water consumption of automatic commercial ice makers. (a) Scope. This... consumption, but instead calculate the energy use rate (kWh/100 lbs Ice) by dividing the energy consumed...

  15. 10 CFR Appendix C to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Dishwashers

    Science.gov (United States)

    2010-01-01

    ... dishwasher means a dishwasher that has a capacity of less than eight place settings plus six serving pieces... than eight place settings plus six serving pieces as specified in ANSI/AHAM DW-1 (Incorporated by... load of eight place settings plus six serving pieces, as specified in section 2.7 of this Appendix. If...

  16. Methods for testing of geometrical down-scaled rotor blades

    DEFF Research Database (Denmark)

    Branner, Kim; Berring, Peter

    further developed since then. Structures in composite materials are generally difficult and time consuming to test for fatigue resistance. Therefore, several methods for testing of blades have been developed and exist today. Those methods are presented in [1]. Current experimental test performed on full...

  17. Testing method for ceramic armour and bare ceramic tiles

    NARCIS (Netherlands)

    Carton, E.P.; Roebroeks, G.H.J.J.

    2016-01-01

    TNO developed an alternative, more configuration independent ceramic test method than the Depth-of-Penetration test method. In this alternative test ceramic tiles and ceramic based armour are evaluated as target without a semi-infinite backing layer. An energy approach is chosen to evaluate and rank

  18. Testing method for ceramic armor and bare ceramic tiles

    NARCIS (Netherlands)

    Carton, E.P.; Roebroeks, G.H.J.J.

    2014-01-01

    TNO has developed an alternative, more configuration independent ceramic test method than the standard Depth-of-Penetration test method. In this test ceramic tiles and ceramic based armor are evaluated as target without a semi-infinite backing layer. An energy approach is chosen to evaluate and rank

  19. Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods

    Energy Technology Data Exchange (ETDEWEB)

    Sandstrom, Mary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Brown, Geoffrey W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Preston, Daniel N. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollard, Colin J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Warner, Kirstin F. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Remmers, Daniel L. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Sorensen, Daniel N. [Naval Surface Warfare Center (NSWC), Indian Head, MD (United States). Indian Head Division; Whinnery, LeRoy L. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Phillips, Jason J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Shelley, Timothy J. [Bureau of Alcohol, Tobacco and Firearms (ATF), Huntsville, AL (United States); Reyes, Jose A. [Applied Research Associates, Tyndall AFB, FL (United States); Hsu, Peter C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Reynolds, John G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-03-25

    The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testing by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.

  20. Comparison of System Identification Methods using Ambient Bridge Test Data

    DEFF Research Database (Denmark)

    Andersen, P.; Brincker, Rune; Peeters, B.

    1999-01-01

    In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method, the stocha......In this paper the performance of four different system identification methods is compared using operational data obtained from an ambient vibration test of the Swiss Z24 highway bridge. The four methods are the frequency domain based peak-picking methods, the polyreference LSCE method...

  1. Standard test methods for arsenic in uranium hexafluoride

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 These test methods are applicable to the determination of total arsenic in uranium hexafluoride (UF6) by atomic absorption spectrometry. Two test methods are given: Test Method A—Arsine Generation-Atomic Absorption (Sections 5-10), and Test Method B—Graphite Furnace Atomic Absorption (Appendix X1). 1.2 The test methods are equivalent. The limit of detection for each test method is 0.1 μg As/g U when using a sample containing 0.5 to 1.0 g U. Test Method B does not have the complete collection details for precision and bias data thus the method appears as an appendix. 1.3 Test Method A covers the measurement of arsenic in uranyl fluoride (UO2F2) solutions by converting arsenic to arsine and measuring the arsine vapor by flame atomic absorption spectrometry. 1.4 Test Method B utilizes a solvent extraction to remove the uranium from the UO2F2 solution prior to measurement of the arsenic by graphite furnace atomic absorption spectrometry. 1.5 Both insoluble and soluble arsenic are measured when UF6 is...

  2. ASTM test methods for composite characterization and evaluation

    Science.gov (United States)

    Masters, John E.

    1994-01-01

    A discussion of the American Society for Testing and Materials is given. Under the topic of composite materials characterization and evaluation, general industry practice and test methods for textile composites are presented.

  3. Standard test method for liquid impingement erosion using rotating apparatus

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers tests in which solid specimens are eroded or otherwise damaged by repeated discrete impacts of liquid drops or jets. Among the collateral forms of damage considered are degradation of optical properties of window materials, and penetration, separation, or destruction of coatings. The objective of the tests may be to determine the resistance to erosion or other damage of the materials or coatings under test, or to investigate the damage mechanisms and the effect of test variables. Because of the specialized nature of these tests and the desire in many cases to simulate to some degree the expected service environment, the specification of a standard apparatus is not deemed practicable. This test method gives guidance in setting up a test, and specifies test and analysis procedures and reporting requirements that can be followed even with quite widely differing materials, test facilities, and test conditions. It also provides a standardized scale of erosion resistance numbers applicab...

  4. A Teaching Method on Basic Chemistry for Freshman : Teaching Method with Pre-test and Post-test

    OpenAIRE

    立木, 次郎; 武井, 庚二

    2003-01-01

    This report deals with a teaching method on basic chemistry for freshman. This teaching method contains guidance and instruction to how to understand basic chemistry. Pre-test and post-test have been put into practice each time. Each test was returned to students at class in the following weeks.

  5. TESTING METHODS FOR MECHANICALLY IMPROVED SOILS: RELIABILITY AND VALIDITY

    Directory of Open Access Journals (Sweden)

    Ana Petkovšek

    2017-10-01

    Full Text Available A possibility of in-situ mechanical improvement for reducing the liquefaction potential of silty sands was investigated by using three different techniques: Vibratory Roller Compaction, Rapid Impact Compaction (RIC and Soil Mixing. Material properties at all test sites were investigated before and after improvement with the laboratory and the in situ tests (CPT, SDMT, DPSH B, static and dynamic load plate test, geohydraulic tests. Correlation between the results obtained by different test methods gave inconclusive answers.

  6. Development and Validation of a Dissolution Test Method for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a dissolution test method for dissolution release of artemether and lumefantrine from tablets. Methods: A single dissolution method for evaluating the in vitro release of artemether and lumefantrine from tablets was developed and validated. The method comprised of a dissolution medium of ...

  7. Generating and testing methods for consumer-oriented product development

    International Nuclear Information System (INIS)

    2001-10-01

    In order to obtain a good insight into various design methods that can be used by product developers to enable them to develop and test useful domotics products (domotics: intelligent systems for the home), an inventory has been made of the methods used in the Netherlands. The inventory is directed at two categories of methods: (1) Methods of getting better acquainted with the user and/or the problem, and of generating novel solutions: generative methods; and (2) Methods of assessing solutions (through various phases of the designing process): testing methods. The first category of methods concentrates on the designing process. In other words: how can the designer realise as much as possible of the workability of (domotics) products during the designing process? The second category aims at testing a design (in whatever shape: drawing, prototype, functional computer animation, etc.) through its users. These are methods of assessing a design at various stages of the designing process [nl

  8. New method of thermal cycling stability test of phase change material

    Directory of Open Access Journals (Sweden)

    Putra Nandy

    2017-01-01

    Full Text Available Phase Change Material (PCM is the most promising material as thermal energy storage nowadays. As thermal energy storage, examination on endurance of material for long-term use is necessary to be carried out. Therefore, thermal cycling test is performed to ensure thermal stability of PCM. This study have found a new method on thermal cycling test of PCM sample by using thermoelectric as heating and cooling element. RT 22 HC was used as PCM sample on this thermal cycling test. The new method had many advantages compared to some references of the same test. It just needed a small container for PCM sample. The thermoelectric could release heat to PCM sample and absorb heat from PCM sample uniformly, respectively, was called as heating and cooling process. Hence, thermoelectric had to be supported by a relay control device to change its polarity so it could heat and cool PCM sample alternately and automatically. On the other hand, the thermoelectric was cheap, easy to be found and available in markets. It can be concluded that new method of thermal cycling test by using thermoelectric as source of heating and cooling can be a new reference for performing thermal cycling test on PCM.

  9. Comparison of test methods for mould growth in buildings

    DEFF Research Database (Denmark)

    Bonderup, Sirid; Gunnarsen, Lars Bo; Knudsen, Sofie Marie

    2016-01-01

    renovation needs. This is of importance when hidden surface testing would require destructive measures and subsequent renovation. After identifying available methods on the Danish market for assessing mould growth in dwellings, a case study was conducted to test the usefulness of the methods in four......The purpose of this work is to compare a range of test methods and kits for assessing whether a building structure is infested by mould fungi. A further purpose of this work is to evaluate whether air-based methods for sampling fungal emissions provide information qualifying decisions concerning...... methods measure different aspects relating to mould growth and vary in selectivity and precision. The two types of air samples indicated low levels of mould growth, even where the results of the other methods indicated high to moderate growth. With methods based on culture and DNA testing some differences...

  10. Verification of intraspecimen method using constant stress tension test of sensitized alloy 600

    International Nuclear Information System (INIS)

    Lee, Seung Ki; Choi, Hoi Su; Hwang, Il Soon

    2005-01-01

    Stress corrosion cracking (SCC) occurring at the Nibase alloy 600 used in the nuclear power plant SG tubes and CRDM penetration nozzles had been reported after long-term operation in the harsh environment. Intraspecimen method was developed to predict the SCC initiation time statistically. [1] By dividing a test area into a number of smaller regions (intraspecimens) having homogeneous physical and chemical condition each SCC initiation in each intraspecimen could be counted as an independent outcome to provide enough number of statistical data. Earlier work of intraspecimen method had many problems in test method and didn't agree with Weibull statistics which is the theoretical base of intraspecimen method. The test method is improved in this intraspecimen test. To find out the root causes of the problems in earlier work and improve the accuracy of intraspecimen method, two kinds of materials are introduced, which are different in grain size but same in chemical composition. Ni-base alloy 600, heat no. J313 and J323 are used as test materials. Specimens of sensitized Alloy 600 are tested under the condition of constant tensile stress and well defined chemical environment therefore we can easily observe typical intergranular stress corrosion cracking (IGSCC). Material with finer grain (J323) showed the areadependence in agreement with theoretical prediction. But material with coarser grain (J313) did not show any significant area-dependence. While SCC initiates earlier at grain boundaries that are oriented close to normal to the stress axis, crack initiation time showed no correlation with grain boundary misorientation estimated by Electron Back Scattered Diffraction (EBSD). From the SCC initiation tests with two test materials, it is concluded that the number of grains in an intraspecimen, degree of sensitization and uniform stress distribution are important parameters to meet Weibull statistics

  11. Comparative study of fracture mechanical test methods for concrete

    DEFF Research Database (Denmark)

    Østergaard, Lennart; Olesen, John Forbes

    2004-01-01

    and the interpretation, i.e. the analysis needed to extract the stress-crack opening relationship, the fracture energy etc. Experiments are carried out with each test configuration using mature, high performance concrete. The results show that the UTT is a highly complicated test, which only under very well controlled...... circumstances will yield the true fracture mechanical properties. It is also shown that both the three point bending test and the WST are well-suited substitutes for the uniaxial tension test.......This paper describes and compares three different fracture mechanical test methods; the uniaxial tension test (UTT), the three point bending test (TPBT) and the wedge splitting test (WST). Potentials and problems with the test methods will be described with regard to the experiment...

  12. Testing and Validation of the Dynamic Interia Measurement Method

    Science.gov (United States)

    Chin, Alexander; Herrera, Claudia; Spivey, Natalie; Fladung, William; Cloutier, David

    2015-01-01

    This presentation describes the DIM method and how it measures the inertia properties of an object by analyzing the frequency response functions measured during a ground vibration test (GVT). The DIM method has been in development at the University of Cincinnati and has shown success on a variety of small scale test articles. The NASA AFRC version was modified for larger applications.

  13. 40 CFR 76.15 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Test methods and procedures. 76.15 Section 76.15 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.15 Test methods and procedures. (a) The...

  14. Methods of Usability Testing in Libraries Web Sites

    Directory of Open Access Journals (Sweden)

    Eman Fawzy

    2006-03-01

    Full Text Available A Study about libraries' web sites evaluation, that is the Usability, the study talking about methods of usability testing and define it, and its important in web sites evaluation, then details the methods of usability: questionnaire, core groups, testing experimental model, cards arrangement, and composed evaluation.

  15. Nondestructive testing methods for 55-gallon, waste storage drums

    International Nuclear Information System (INIS)

    Ferris, R.H.; Hildebrand, B.P.; Hockey, R.L.; Riechers, D.M.; Spanner, J.C.; Duncan, D.R.

    1993-06-01

    The Westinghouse Hanford Company (WHC) authorized Pacific Northwest Laboratory (PNL) to conduct a feasibility study to identify promising nondestructive testing (NDT) methods for detecting general and localized (both pitting and pinhole) corrosion in the 55-gal drums that are used to store solid waste materials at the Hanford Site. This document presents results obtained during a literature survey, identifies the relevant reference materials that were reviewed, provides a technical description of the methods that were evaluated, describes the laboratory tests that were conducted and their results, identifies the most promising candidate methods along with the rationale for these selections, and includes a work plan for recommended follow-on activities. This report contains a brief overview and technical description for each of the following NDT methods: magnetic testing techniques; eddy current testing; shearography; ultrasonic testing; radiographic computed tomography; thermography; and leak testing with acoustic detection

  16. Test methods for protective footwear against AP mine blast

    NARCIS (Netherlands)

    Cronin, D.S.; Williams, K.; Bass, C.R.; Magnan, P.; Dosquet, F.; Bergeron, D.M.; Bree, J.L.M.J. van

    2003-01-01

    The testing and development of protective footwear for anti-personnel landmine blast threats is of great importance to civilian and military deminers, and peacekeepers. This study will review the wide range of test methods that have been developed by NATO countries to test footwear against the

  17. Application of Bayesian Methods for Detecting Fraudulent Behavior on Tests

    Science.gov (United States)

    Sinharay, Sandip

    2018-01-01

    Producers and consumers of test scores are increasingly concerned about fraudulent behavior before and during the test. There exist several statistical or psychometric methods for detecting fraudulent behavior on tests. This paper provides a review of the Bayesian approaches among them. Four hitherto-unpublished real data examples are provided to…

  18. Evaluation of methods to leak test sealed radiation sources

    International Nuclear Information System (INIS)

    Arbeau, N.D.; Scott, C.K.

    1987-04-01

    The methods for the leak testing of sealed radiation sources were reviewed. One hundred and thirty-one equipment vendors were surveyed to identify commercially available leak test instruments. The equipment is summarized in tabular form by radiation type and detector type for easy reference. The radiation characteristics of the licensed sources were reviewed and summarized in a format that can be used to select the most suitable detection method. A test kit is proposed for use by inspectors when verifying a licensee's test procedures. The general elements of leak test procedures are discussed

  19. Stopping test of iterative methods for solving PDE

    International Nuclear Information System (INIS)

    Wang Bangrong

    1991-01-01

    In order to assure the accuracy of the numerical solution of the iterative method for solving PDE (partial differential equation), the stopping test is very important. If the coefficient matrix of the system of linear algebraic equations is strictly diagonal dominant or irreducible weakly diagonal dominant, the stopping test formulas of the iterative method for solving PDE is proposed. Several numerical examples are given to illustrate the applications of the stopping test formulas

  20. 40 CFR 63.344 - Performance test requirements and test methods.

    Science.gov (United States)

    2010-07-01

    ... electroplating tanks or chromium anodizing tanks. The sampling time and sample volume for each run of Methods 306... Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test... Emissions From Decorative and Hard Chromium Electroplating and Anodizing Operations,” appendix A of this...

  1. Evaluation of Test Method for Solar Collector Efficiency

    DEFF Research Database (Denmark)

    Fan, Jianhua; Shah, Louise Jivan; Furbo, Simon

    The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximat...... and the sky temperature. Based on the investigations, recommendations for change of the test methods and test conditions are considered. The investigations are carried out within the NEGST (New Generation of Solar Thermal Systems) project financed by EU.......The test method of the standard EN12975-2 (European Committee for Standardization, 2004) is used by European test laboratories to determine the efficiency of solar collectors. In the test methods the mean solar collector fluid temperature in the solar collector, Tm is determined by the approximated...... equation where Tin is the inlet temperature to the collector and Tout is the outlet temperature from the collector. The specific heat of the solar collector fluid is in the test method as an approximation determined as a constant equal to the specific heat of the solar collector fluid at the temperature Tm...

  2. Study of test methods for radionuclide migration in aerated zone

    International Nuclear Information System (INIS)

    Li Shushen; Guo Zede; Wang Zhiming

    1993-01-01

    Aerated zone is an important natural barrier against transport of radionuclides released from disposal facilities of LLRW. This paper introduces study methods for radionuclide migration in aerated zone, including determination of water movement, laboratory simulation test, and field tracing test. For one purpose, results obtained with different methods are compared. These methods have been used in a five-year cooperative research project between CIRP and JAERI for an establishment of methodology for safety assessment on shallow land disposal of LLRW

  3. Standard test methods for performance characteristics of metallic bonded resistance strain gages

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1992-01-01

    1.1 The purpose of this standard is to provide uniform test methods for the determination of strain gauge performance characteristics. Suggested testing equipment designs are included. 1.2 Test Methods E 251 describes methods and procedures for determining five strain gauge parameters: Section Part I—General Requirements 7 Part II—Resistance at a Reference Temperature 8 Part III—Gauge Factor at a Reference Temperature 9 Part IV—Temperature Coefficient of Gauge Factor\t10 Part V—Transverse Sensitivity\t11 Part VI—Thermal Output\t12 1.3 Strain gauges are very sensitive devices with essentially infinite resolution. Their response to strain, however, is low and great care must be exercised in their use. The performance characteristics identified by these test methods must be known to an acceptable accuracy to obtain meaningful results in field applications. 1.3.1 Strain gauge resistance is used to balance instrumentation circuits and to provide a reference value for measurements since all data are...

  4. Reliability of different methods used for forming of working samples in the laboratory for seed testing

    Directory of Open Access Journals (Sweden)

    Opra Branislava

    2000-01-01

    Full Text Available The testing of seed quality starts from the moment a sample is formed in a warehouse during processing or packaging of the seed. The seed sampling as the process of obtaining the working sample also assumes each step undertaken during its testing in the laboratory. With the aim of appropriate forming of a seed sample in the laboratory, the usage of seed divider is prescribed for large seeded species (such as seed the size of wheat or larger (ISTA Rules, 1999. The aim of this paper was the comparison of different methods used for obtaining the working samples of maize and wheat seeds using conical, soil and centrifugal dividers. The number of seed of added admixtures confirmed the reliability of working samples formation. To each maize sample (1000 g 10 seeds of the following admixtures were added: Zea mays L. (red pericarp, Hordeum vulgäre L., Triticum aestivum L., and Glycine max (L. Merr. Two methods were used for formation of maze seed working sample. To wheat samples (1000 g 10 seeds of each of the following species were added: Avena saliva (hulled seeds, Hordeum vulgäre L., Galium tricorne Stokes, and Polygonum lapatifolmm L. For formation of wheat seed working samples four methods were used. Optimum of 9, but not less than 7 seeds of admixture were due to be determined in the maize seed working sample, while for wheat, at least one seed of admixture was expected to be found in the working sample. The obtained results confirmed that the formation of the maize seed working samples was the most reliable when centrifugal divider, the first method was used (average of admixture - 9.37. From the observed admixtures the seed of Triticum aestivum L. was the most uniformly distributed, the first method also being used (6.93. The second method gains high average values satisfying the given criterion, but it should be used with previous homogenization of the sample being tested. The forming of wheat seed working samples is the most reliable if the

  5. Evaluation of snubber functional test methods: Tier 1

    International Nuclear Information System (INIS)

    Brown, D.P.

    1993-07-01

    The objective of the research is to establish technical bases in support of efforts on the part of the Snubber Utility Group (SNUG) and the Subsection ISTD Working Group of the ASME O ampersand M Code in developing guidelines and methodologies for snubber functional testing to ensure that snubbers are tested in a manner that ensures reliable and meaningful test results. The methodology used in this research includes both a review of available industry information as well as the testing of different snubber models using various test machines. Information is provided pertaining to current industry practices in regard to snubber testing including recommended test procedures, technical description of various test machines, and the number and types of snubbers used in the nuclear power industry. A review of previous test methodology research conducted by the Snubber Utility Group is also included. The effects of variations in controllable test parameters on snubber test results are discussed. Also included are the results of confirmatory tests in which various snubber models were tested using various test machines. Recommendations are provided for standard test methods to be included in Subsection ISTD of the ASME O ampersand M Code [4]. General information and recommendations are provided that may be used by utility personnel in specifying snubber test equipment that is most suited for plant-specific needs as well as information that may be effectively used in the review and interpretation of test results

  6. Pellicle transmission uniformity requirements

    Science.gov (United States)

    Brown, Thomas L.; Ito, Kunihiro

    1998-12-01

    Controlling critical dimensions of devices is a constant battle for the photolithography engineer. Current DUV lithographic process exposure latitude is typically 12 to 15% of the total dose. A third of this exposure latitude budget may be used up by a variable related to masking that has not previously received much attention. The emphasis on pellicle transmission has been focused on increasing the average transmission. Much less, attention has been paid to transmission uniformity. This paper explores the total demand on the photospeed latitude budget, the causes of pellicle transmission nonuniformity and examines reasonable expectations for pellicle performance. Modeling is used to examine how the two primary errors in pellicle manufacturing contribute to nonuniformity in transmission. World-class pellicle transmission uniformity standards are discussed and a comparison made between specifications of other components in the photolithographic process. Specifications for other materials or parameters are used as benchmarks to develop a proposed industry standard for pellicle transmission uniformity.

  7. A Teaching Method on Basic Chemistry for Freshman (II) : Teaching Method with Pre-test and Post-test

    OpenAIRE

    立木, 次郎; 武井, 庚二

    2004-01-01

    This report deals with review of a teaching method on basic chemistry for freshman in this first semester. We tried to review this teaching method with pre-test and post-test by means of the official and private questionnaires. Several hints and thoughts on teaching skills are obtained from this analysis.

  8. UVIS Flat Field Uniformity

    Science.gov (United States)

    Quijano, Jessica Kim

    2009-07-01

    The stability and uniformity of the low-frequency flat fields {L-flat} of the UVIS detector will be assessed by using multiple-pointing observations of the globular clusters 47 Tucanae {NGC104} and Omega Centauri {NGC5139}, thus imaging moderately dense stellar fields. By placing the same star over different portions of the detector and measuring relative changes in its brightness, it will be possible to determine local variations in the response of the UVIS detector. Based on previous experience with STIS and ACS, it is deemed that a total of 9 different pointings will suffice to provide adequate characterization of the flat field stability in any given band. For each filter to be tested, the baseline consists of 9 pointings in a 3X3 box pattern with dither steps of about 25% of the FOV, or 40.5", in either the x or y direction {useful also for CTE measurements, if needed in the future}. During SMOV, the complement of filters to be tested is limited to the following 6 filters: F225W, F275W, F336W, for Omega Cen, and F438W, F606W, and F814W for 47 Tuc. Three long exposures for each target are arranged such that the initial dither position is observed with the appropriate filters for that target within one orbit at a single pointing, so that filter-to-filter differences in the observed star positions can be checked. In addition to the 9 baseline exposures, two sets of short exposures will be taken:a} one short exposure will be taken of OmegaCen with each of the visible filters {F438W, F606W and F814W} in order to check the geometric distortion solution to be obtained with the data from proposal 11444;b} for each target, a single short exposure will be taken with each filter to facilitate the study of the PSF as a function of position on the detector by providing unsaturated images of sparsely-spaced bright stars.This proposal corresponds to Activity Description ID WF39. It should execute only after the following proposal has executed:WF21 - 11434

  9. 40 CFR 63.1257 - Test methods and compliance procedures.

    Science.gov (United States)

    2010-07-01

    ... chemical engineering principles, measurable process parameters, or physical or chemical laws or properties... flow rate and concentration; temperature; and the reaction kinetics of the constituents with the... Method 8260 or 8270 in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA...

  10. Standard test method for galling resistance of material couples

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This test method covers a laboratory test that ranks the galling resistance of material couples using a quantitative measure. Bare metals, alloys, nonmetallic materials, coatings, and surface modified materials may be evaluated by this test method. 1.2 This test method is not designed for evaluating the galling resistance of material couples sliding under lubricated conditions, because galling usually will not occur under lubricated sliding conditions using this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. New methods of testing nonlinear hypothesis using iterative NLLS estimator

    Science.gov (United States)

    Mahaboob, B.; Venkateswarlu, B.; Mokeshrayalu, G.; Balasiddamuni, P.

    2017-11-01

    This research paper discusses the method of testing nonlinear hypothesis using iterative Nonlinear Least Squares (NLLS) estimator. Takeshi Amemiya [1] explained this method. However in the present research paper, a modified Wald test statistic due to Engle, Robert [6] is proposed to test the nonlinear hypothesis using iterative NLLS estimator. An alternative method for testing nonlinear hypothesis using iterative NLLS estimator based on nonlinear hypothesis using iterative NLLS estimator based on nonlinear studentized residuals has been proposed. In this research article an innovative method of testing nonlinear hypothesis using iterative restricted NLLS estimator is derived. Pesaran and Deaton [10] explained the methods of testing nonlinear hypothesis. This paper uses asymptotic properties of nonlinear least squares estimator proposed by Jenrich [8]. The main purpose of this paper is to provide very innovative methods of testing nonlinear hypothesis using iterative NLLS estimator, iterative NLLS estimator based on nonlinear studentized residuals and iterative restricted NLLS estimator. Eakambaram et al. [12] discussed least absolute deviation estimations versus nonlinear regression model with heteroscedastic errors and also they studied the problem of heteroscedasticity with reference to nonlinear regression models with suitable illustration. William Grene [13] examined the interaction effect in nonlinear models disused by Ai and Norton [14] and suggested ways to examine the effects that do not involve statistical testing. Peter [15] provided guidelines for identifying composite hypothesis and addressing the probability of false rejection for multiple hypotheses.

  12. Thermoelastic analysis of non-uniform pressurized functionally graded cylinder with variable thickness using first order shear deformation theory(FSDT) and perturbation method

    Science.gov (United States)

    Khoshgoftar, M. J.; Mirzaali, M. J.; Rahimi, G. H.

    2015-11-01

    Recently application of functionally graded materials(FGMs) have attracted a great deal of interest. These materials are composed of various materials with different micro-structures which can vary spatially in FGMs. Such composites with varying thickness and non-uniform pressure can be used in the aerospace engineering. Therefore, analysis of such composite is of high importance in engineering problems. Thermoelastic analysis of functionally graded cylinder with variable thickness under non-uniform pressure is considered. First order shear deformation theory and total potential energy approach is applied to obtain the governing equations of non-homogeneous cylinder. Considering the inner and outer solutions, perturbation series are applied to solve the governing equations. Outer solution for out of boundaries and more sensitive variable in inner solution at the boundaries are considered. Combining of inner and outer solution for near and far points from boundaries leads to high accurate displacement field distribution. The main aim of this paper is to show the capability of matched asymptotic solution for different non-homogeneous cylinders with different shapes and different non-uniform pressures. The results can be used to design the optimum thickness of the cylinder and also some properties such as high temperature residence by applying non-homogeneous material.

  13. Nuclear EMP: stripline test method for measuring transfer impedance

    International Nuclear Information System (INIS)

    Miller, J.S.

    1975-11-01

    A method for measuring the transfer impedance of flat metal joints for frequencies to 100 MHz has been developed which makes use of striplines. The stripline method, which has similarities to the quadraxial method used for cylindrical components, is described and sets of test results are given. The transfer impedance of a simple joint is modeled as a spurious hyperbolic curve, and a close curve fit to transfer impedance test data from various samples is demonstrated for both the stripline and the quadraxial methods. Validity checks of the test data are discussed using the curve model and other criteria. The method was developed for testing riveted joints which form the avionics bays on B-1s. The joints must provide shielding from EMP currents

  14. Uniform-droplet spray forming

    Energy Technology Data Exchange (ETDEWEB)

    Blue, C.A.; Sikka, V.K. [Oak Ridge National Lab., TN (United States); Chun, Jung-Hoon [Massachusetts Institute of Technology, Cambridge, MA (United States); Ando, T. [Tufts Univ., Medford, MA (United States)

    1997-04-01

    The uniform-droplet process is a new method of liquid-metal atomization that results in single droplets that can be used to produce mono-size powders or sprayed-on to substrates to produce near-net shapes with tailored microstructure. The mono-sized powder-production capability of the uniform-droplet process also has the potential of permitting engineered powder blends to produce components of controlled porosity. Metal and alloy powders are commercially produced by at least three different methods: gas atomization, water atomization, and rotating disk. All three methods produce powders of a broad range in size with a very small yield of fine powders with single-sized droplets that can be used to produce mono-size powders or sprayed-on substrates to produce near-net shapes with tailored microstructures. The economical analysis has shown the process to have the potential of reducing capital cost by 50% and operating cost by 37.5% when applied to powder making. For the spray-forming process, a 25% savings is expected in both the capital and operating costs. The project is jointly carried out at Massachusetts Institute of Technology (MIT), Tuffs University, and Oak Ridge National Laboratory (ORNL). Preliminary interactions with both finished parts and powder producers have shown a strong interest in the uniform-droplet process. Systematic studies are being conducted to optimize the process parameters, understand the solidification of droplets and spray deposits, and develop a uniform-droplet-system (UDS) apparatus appropriate for processing engineering alloys.

  15. Test Methods for Telemetry Systems and Subsystems Volume 1: Test Methods for Vehicle Telemetry Systems

    Science.gov (United States)

    2012-05-01

    Noise Test .......................................................................... 5-106 5.29 Transmitter Bit Error Probability ( BEP ) versus Eb/N0...modulation BC Bus controller BCD Binary coded decimal BCM Bit code modulation BEP Bit error probability BER Bit error rate BPF Band-pass filter BW...5.29 Transmitter Phase Noise Test X X 5.30 Transmitter Bit Error Probability ( BEP ) versus Eb/N0 X (5) X (5) X X X X 5.31 Software

  16. The influence of technical testing methods on perceptions of constructions

    International Nuclear Information System (INIS)

    Oestberg, Gustaf

    2002-01-01

    In principle, methods of testing the reliability and safety of constructions are designed with the aim of representing critical conditions for their use. Because of variations within technical systems, including the one for which a certain test was once developed, the validity of the method also varies. The adoption of a standardized test for different applications had to be based on the assumption that the test deals adequately with a real situation. As a consequence of this acceptance of a trustworthy relationship between test and reality, an imprint of the former on the latter occurs. This effect may even cause the perception of a reality to be defined by the corresponding test. Examples of such an influence may be found in the field of materials testing. Related phenomena can be dealt with by reference to current concepts of cognitive science and psychology of the perception of images

  17. Accelerated Test Method for Corrosion Protective Coatings Project

    Science.gov (United States)

    Falker, John; Zeitlin, Nancy; Calle, Luz

    2015-01-01

    This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as accurately and reliably as current long-term atmospheric exposure tests. This new accelerated test method will shorten the time needed to evaluate the corrosion protection performance of coatings for NASA's critical ground support structures. Lifetime prediction for spaceport structure coatings has a 5-year qualification cycle using atmospheric exposure. Current accelerated corrosion tests often provide false positives and negatives for coating performance, do not correlate to atmospheric corrosion exposure results, and do not correlate with atmospheric exposure timescales for lifetime prediction.

  18. Test Method for Spalling of Fire Exposed Concrete

    DEFF Research Database (Denmark)

    Hertz, Kristian Dahl; Sørensen, Lars Schiøtt

    2005-01-01

    A new material test method is presented for determining whether or not an actual concrete may suffer from explosive spalling at a specified moisture level. The method takes into account the effect of stresses from hindered thermal expansion at the fire-exposed surface. Cylinders are used, which...... in many countries serve as standard specimens for testing the compressive strength. Consequently, the method is quick, cheap and easy to use in comparison to the alternative of testing full-scale or semi full-scale structures with correct humidity, load and boundary conditions. A number of concretes have...

  19. The Validation of NAA Method Used as Test Method in Serpong NAA Laboratory

    International Nuclear Information System (INIS)

    Rina-Mulyaningsih, Th.

    2004-01-01

    The Validation Of NAA Method Used As Test Method In Serpong NAA Laboratory. NAA Method is a non standard testing method. The testing laboratory shall validate its using method to ensure and confirm that it is suitable with application. The validation of NAA methods have been done with the parameters of accuracy, precision, repeatability and selectivity. The NIST 1573a Tomato Leaves, NIES 10C Rice flour unpolished and standard elements were used in this testing program. The result of testing with NIST 1573a showed that the elements of Na, Zn, Al and Mn are met from acceptance criteria of accuracy and precision, whereas Co is rejected. The result of testing with NIES 10C showed that Na and Zn elements are met from acceptance criteria of accuracy and precision, but Mn element is rejected. The result of selectivity test showed that the value of quantity is between 0.1-2.5 μg, depend on the elements. (author)

  20. Mechanical/structural performance test method of a spacer grid

    International Nuclear Information System (INIS)

    Yoon, Kyung Ho

    2000-06-01

    The spacer grid is one of the main structural components in the fuel assembly, which supports the fuel rods, guides cooling water, and protects the system from an external impact load, such as earthquakes. In order to develop the spacer grid with the high mechanical performance, the mechanical and structural properties of the spacer grids must be extensively examined while designing it. In this report, the mechanical/structural test methods, i.e. the characteristic test of a spacer grid spring or dimple, static buckling test of a partial or full size spacer grid and dynamic impact test of them are described. The characteristic test of a spacer grid spring or dimple is accomplished with universal tensile test machine, a specimen is fixed with test fixture and then applied compressive load. The characteristic test data is saved at loading and unloading event. The static buckling test of a partial or full size spacer grid is executed with the same universal tensile testing machine, a specimen is fixed between cross-heads and then applied the compressive load. The buckling strength is decided the maximum strength at load vs. displacement curve. The dynamic impact test of a partial or full size spacer grid is performed with pendulum type impact machine and free fall shock test machine, a specimen is fixed with test fixture and then applied the impact load by impact hammer. Specially, the pendulum type impact test machine is also possible under the operating temperature because a furnace is separately attached with test machine

  1. Comparison of high efficiency particulate filter testing methods

    International Nuclear Information System (INIS)

    1985-01-01

    High Efficiency Particulate Air (HEPA) filters are used for the removal of submicron size particulates from air streams. In nuclear industry they are used as an important engineering safeguard to prevent the release of air borne radioactive particulates to the environment. HEPA filters used in the nuclear industry should therefore be manufactured and operated under strict quality control. There are three levels of testing HEPA filters: i) testing of the filter media; ii) testing of the assembled filter including filter media and filter housing; and iii) on site testing of the complete filter installation before putting into operation and later for the purpose of periodic control. A co-ordinated research programme on particulate filter testing methods was taken up by the Agency and contracts were awarded to the Member Countries, Belgium, German Democratic Republic, India and Hungary. The investigations carried out by the participants of the present co-ordinated research programme include the results of the nowadays most frequently used HEPA filter testing methods both for filter medium test, rig test and in-situ test purposes. Most of the experiments were carried out at ambient temperature and humidity, but indications were given to extend the investigations to elevated temperature and humidity in the future for the purpose of testing the performance of HEPA filter under severe conditions. A major conclusion of the co-ordinated research programme was that it was not possible to recommend one method as a reference method for in situ testing of high efficiency particulate air filters. Most of the present conventional methods are adequate for current requirements. The reasons why no method is to be recommended were multiple, ranging from economical aspects, through incompatibility of materials to national regulations

  2. Standard Test Method for Saltwater Pressure Immersion and Temperature Testing of Photovoltaic Modules for Marine Environments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method provides a procedure for determining the ability of photovoltaic modules to withstand repeated immersion or splash exposure by seawater as might be encountered when installed in a marine environment, such as a floating aid-to-navigation. A combined environmental cycling exposure with modules repeatedly submerged in simulated saltwater at varying temperatures and under repetitive pressurization provides an accelerated basis for evaluation of aging effects of a marine environment on module materials and construction. 1.2 This test method defines photovoltaic module test specimens and requirements for positioning modules for test, references suitable methods for determining changes in electrical performance and characteristics, and specifies parameters which must be recorded and reported. 1.3 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.4 The values stated in SI units are to be ...

  3. Restricting uniformly open surjections

    Czech Academy of Sciences Publication Activity Database

    Kania, Tomasz; Rmoutil, M.

    2017-01-01

    Roč. 355, č. 9 (2017), s. 925-928 ISSN 1631-073X Institutional support: RVO:67985840 Keywords : Banach space * uniform spaces Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 0.396, year: 2016 http://www.sciencedirect.com/science/article/pii/S1631073X17302261?via%3Dihub

  4. Uniformly irradiated polymer film

    International Nuclear Information System (INIS)

    Fowler, S.L.

    1979-01-01

    Irradiated film having substantial uniformity in the radiation dosage profile is produced by irradiating the film within a trough having lateral deflection blocks disposed adjacent the film edges for deflecting electrons toward the surface of the trough bottom for further deflecting the electrons toward the film edge

  5. In Silico Toxicology – Non-Testing Methods

    Science.gov (United States)

    Raunio, Hannu

    2011-01-01

    In silico toxicology in its broadest sense means “anything that we can do with a computer in toxicology.” Many different types of in silico methods have been developed to characterize and predict toxic outcomes in humans and environment. The term non-testing methods denote grouping approaches, structure–activity relationship, and expert systems. These methods are already used for regulatory purposes and it is anticipated that their role will be much more prominent in the near future. This Perspective will delineate the basic principles of non-testing methods and evaluate their role in current and future risk assessment of chemical compounds. PMID:21772821

  6. Methods and characteristics of assembly language software testing

    International Nuclear Information System (INIS)

    Wang Lingfang

    2001-01-01

    Single chip micro-controllers are widely implemented to the controlling and testing products in industrial controlling and national defence embedded controlling systems. The invalidation of the source programs could lead to the unreliability of the whole systems, even to cause fatal results. Therefore, software testing is the necessary measures to reduce the mistakes and to improve the quality of the software. In the paper, the development of the software testing is presented. The distinctions between the assembly language testing and those of the high level languages is introduced. And the essential flow and methods of software testing are discussed in detail

  7. Relative Merits of Four Methods for Scoring Cloze Tests.

    Science.gov (United States)

    Brown, James Dean

    1980-01-01

    Describes study comparing merits of exact answer, acceptable answer, clozentropy and multiple choice methods for scoring tests. Results show differences among reliability, mean item facility, discrimination and usability, but not validity. (BK)

  8. A True-False Test on Methods of Typewriting Instruction.

    Science.gov (United States)

    West, Leonard J.

    1984-01-01

    Presents a true-false test on typewriting instruction to illustrate the effects of educational lag, publishing practices, and deficiencies in preservice and inservice teacher education upon teaching methods. (SK)

  9. Test Methods for Effects on Organisms:Springtails

    OpenAIRE

    Krogh, P. H.

    1997-01-01

    NORD-UTTE er Nordisk koordineringsgrupp för utvekling av testmetoder inom toxicologi och ekotoxicology. The Nordic Co-ordination Group for the Development of Test Methods for Toxicology and Ecotoxicology

  10. From the Kirsch-Kress potential method via the range test to the singular sources method

    International Nuclear Information System (INIS)

    Potthast, R; Schulz, J

    2005-01-01

    We review three reconstruction methods for inverse obstacle scattering problems. We will analyse the relation between the Kirsch-Kress potential method 1986, the range test of Kusiak, Potthast and Sylvester (2003) and the singular sources method of Potthast (2000). In particular, we show that the range test is a logical extension of the Kirsch-Kress method into the category of sampling methods employing the tool of domain sampling. Then we will show how a multi-wave version of the range test can be set up and we will work out its relation to the singular sources method. Numerical examples and demonstrations will be provided

  11. Two micro fatigue test methods for irradiated materials

    International Nuclear Information System (INIS)

    Nunomura, Shigetomo; Noguchi, Shinji; Okamura, Yuichi; Kumai, Shinji

    1993-01-01

    This paper demonstrates two miniature fatigue test methods in response to the requirements of the fusion reactor wall materials development program. It is known that the fatigue strength evaluated by the axial loading test is independent of the specimen size, while that evaluated by the bend test or torsion test is dependent upon the size of specimen. The new type of gripping system for the axial, tension-tension, fatigue testing of TEM disk-size specimens that has been developed is described in this paper. An alignment tool assists in gripping the miniature specimen. The miniature tension-tension fatigue test method seems to provide reliable S-N curves for SUS304 and SUS316L stainless steels. An indentation method has also been developed to determine fatigue properties. A hard steel ball or ceramic ball was used for cyclically loading the specimen, and an S-N curve was subsequently obtained. The merit of this method is primarily simple handling. S-N curves obtained from four materials by this indentation method compared well with those obtained from the rotary bend fatigue test employing a standard-size specimen

  12. Review of Artificial Abrasion Test Methods for PV Module Technology

    Energy Technology Data Exchange (ETDEWEB)

    Miller, David C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Muller, Matt T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Simpson, Lin J. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-08-01

    This review is intended to identify the method or methods--and the basic details of those methods--that might be used to develop an artificial abrasion test. Methods used in the PV literature were compared with their closest implementation in existing standards. Also, meetings of the International PV Quality Assurance Task Force Task Group 12-3 (TG12-3, which is concerned with coated glass) were used to identify established test methods. Feedback from the group, which included many of the authors from the PV literature, included insights not explored within the literature itself. The combined experience and examples from the literature are intended to provide an assessment of the present industry practices and an informed path forward. Recommendations toward artificial abrasion test methods are then identified based on the experiences in the literature and feedback from the PV community. The review here is strictly focused on abrasion. Assessment methods, including optical performance (e.g., transmittance or reflectance), surface energy, and verification of chemical composition were not examined. Methods of artificially soiling PV modules or other specimens were not examined. The weathering of artificial or naturally soiled specimens (which may ultimately include combined temperature and humidity, thermal cycling and ultraviolet light) were also not examined. A sense of the purpose or application of an abrasion test method within the PV industry should, however, be evident from the literature.

  13. Tolerancing a lens for LED uniform illumination

    Science.gov (United States)

    Ryu, Jieun; Sasian, Jose

    2017-08-01

    A method to evaluate tolerance sensitivities for lenses used to produce uniform illumination is presented. Closed form surfaces are used to define optical surfaces and relative illumination is calculated from light etendue considerations.

  14. Methodical approaches to solving special problems of testing. Seminar papers

    International Nuclear Information System (INIS)

    1996-01-01

    This Seminar volume introduces concepts and applications from different areas of application of ultrasonic testing and other non-destructive test methods in 18 lectures, in order to give an idea of new trends in development and stimuli for special solutions to problems. 3 articles were recorded separately for the ENERGY data bank. (orig./MM) [de

  15. Nondestructive testing methods in building industry '83. Part 1

    International Nuclear Information System (INIS)

    1983-10-01

    The conference heard 52 papers of which 11 were incorporated in INIS. The subject of these was the use of radiometric methods and instruments for nondestructive testing of building materials and ways of testing the quality of concrete during nuclear power plant construction. (J.P.)

  16. 40 CFR 63.425 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... maximum allowable 5-minute pressure increase is 130 mm H2 O (5 in. H2 O). (f) Leak detection test. The leak detection test shall be performed using Method 21, appendix A, 40 CFR part 60, except omit section... between each leak detection. The duration of the purge shall be in excess of two instrument response times...

  17. 40 CFR 63.1046 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ...) National Emission Standards for Oil-Water Separators and Organic-Water Separators § 63.1046 Test methods... vapor leakage could occur) on the cover and associated closure devices shall be checked. Potential leak... test, the cover and closure devices shall be secured in the closed position. (3) The detection...

  18. Moisture distribution in sludges based on different testing methods

    Institute of Scientific and Technical Information of China (English)

    Wenyi Deng; Xiaodong Li; Jianhua Yan; Fei Wang; Yong Chi; Kefa Cen

    2011-01-01

    Moisture distributions in municipal sewage sludge, printing and dyeing sludge and paper mill sludge were experimentally studied based on four different methods, i.e., drying test, thermogravimetric-differential thermal analysis (TG-DTA) test, thermogravimetricdifferential scanning calorimetry (TG-DSC) test and water activity test. The results indicated that the moistures in the mechanically dewatered sludges were interstitial water, surface water and bound water. The interstitial water accounted for more than 50% wet basis (wb) of the total moisture content. The bond strength of sludge moisture increased with decreasing moisture content, especially when the moisture content was lower than 50% wb. Furthermore, the comparison among the four different testing methods was presented.The drying test was advantaged by its ability to quantify free water, interstitial water, surface water and bound water; while TG-DSC test, TG-DTA test and water activity test were capable of determining the bond strength of moisture in sludge. It was found that the results from TG-DSC and TG-DTA test are more persuasive than water activity test.

  19. Mirror bootstrap method for testing hypotheses of one mean

    OpenAIRE

    Varvak, Anna

    2012-01-01

    The general philosophy for bootstrap or permutation methods for testing hypotheses is to simulate the variation of the test statistic by generating the sampling distribution which assumes both that the null hypothesis is true, and that the data in the sample is somehow representative of the population. This philosophy is inapplicable for testing hypotheses for a single parameter like the population mean, since the two assumptions are contradictory (e.g., how can we assume both that the mean o...

  20. Overview of multi-input frequency domain modal testing methods with an emphasis on sine testing

    Science.gov (United States)

    Rost, Robert W.; Brown, David L.

    1988-01-01

    An overview of the current state of the art multiple-input, multiple-output modal testing technology is discussed. A very brief review of the current time domain methods is given. A detailed review of frequency and spatial domain methods is presented with an emphasis on sine testing.

  1. 40 CFR 60.1300 - What test methods must I use to stack test?

    Science.gov (United States)

    2010-07-01

    ... to the Administrator for approval under § 60.8(b) to use a reference method with minor changes in... 40 Protection of Environment 6 2010-07-01 2010-07-01 false What test methods must I use to stack test? 60.1300 Section 60.1300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR...

  2. Test report for cesium powder and pellets inner container decontamination method determination test

    International Nuclear Information System (INIS)

    Kelly, D.L.

    1998-01-01

    This report documents the decontamination method determination testing that was performed on three cesium powder and pellets inner container test specimens The test specimens were provided by B and W Hanford Company (BVMC). The tests were conducted by the Numatec Hanford Company (NHC), in the 305 Building. Photographic evidence was also provided by NHC. The Test Plan and Test Report were provided by Waste Management Federal Services, Inc., Northwest Operations. Witnesses to testing included a test engineer, a BC project engineer, and a BC Quality Assurance (QA) representative. The Test Plan was modified with the mutual decision of the test engineer, the BWHC project engineer, and the BVMC QA representative. The results of this decision were written in red (permanent type) ink on the official copy of the test procedure, Due to the extent of the changes, a summary of the test results are provided in Section 3.0 of this Test Report. In addition, a copy of the official copy field documentation obtained during testing is included in Appendix A. The original Test Plan (HNF-2945) will be revised to indicate that extensive changes were required in the field during testing, however, the test documentation will stand as is (i.e., it will not be retyped, text shaded, etc.) due to the inclusion of the test parameters and results into this Test Report

  3. Satellite Vibration Testing: Angle optimisation method to Reduce Overtesting

    Science.gov (United States)

    Knight, Charly; Remedia, Marcello; Aglietti, Guglielmo S.; Richardson, Guy

    2018-06-01

    Spacecraft overtesting is a long running problem, and the main focus of most attempts to reduce it has been to adjust the base vibration input (i.e. notching). Instead this paper examines testing alternatives for secondary structures (equipment) coupled to the main structure (satellite) when they are tested separately. Even if the vibration source is applied along one of the orthogonal axes at the base of the coupled system (satellite plus equipment), the dynamics of the system and potentially the interface configuration mean the vibration at the interface may not occur all along one axis much less the corresponding orthogonal axis of the base excitation. This paper proposes an alternative testing methodology in which the testing of a piece of equipment occurs at an offset angle. This Angle Optimisation method may have multiple tests but each with an altered input direction allowing for the best match between all specified equipment system responses with coupled system tests. An optimisation process that compares the calculated equipment RMS values for a range of inputs with the maximum coupled system RMS values, and is used to find the optimal testing configuration for the given parameters. A case study was performed to find the best testing angles to match the acceleration responses of the centre of mass and sum of interface forces for all three axes, as well as the von Mises stress for an element by a fastening point. The angle optimisation method resulted in RMS values and PSD responses that were much closer to the coupled system when compared with traditional testing. The optimum testing configuration resulted in an overall average error significantly smaller than the traditional method. Crucially, this case study shows that the optimum test campaign could be a single equipment level test opposed to the traditional three orthogonal direction tests.

  4. An evaluation of the whole effluent toxicity test method

    International Nuclear Information System (INIS)

    Osteen, D.V.

    1999-01-01

    Whole effluent toxicity (WET) testing has become increasingly more important to the Environmental Protection Agency (EPA) and the States in the permitting of wastewater discharges from industry and municipalities. The primary purpose of the WET test is to protect aquatic life by predicting the effect of an effluent on the receiving stream. However, there are both scientific and regulatory concerns that using WET tests to regulate industrial effluents may result in either false positives and/or false negatives. In order to realistically predict the effect of an effluent on the receiving stream, the test should be as representative as possible of the conditions in the receiving stream. Studies (Rand and Petrocelli 1985) suggested several criteria for an ideal aquatic toxicity test organism, one of which is that the organism be indigenous to, or representative of, the ecosystem receiving the effluent. The other component needed in the development of a predictive test is the use of the receiving stream water or similar synthetic water as the control and dilution water in the test method. Use of an indigenous species and receiving water in the test should help reduce the variability in the method and allow the test to predict the effect of the effluent on the receiving stream. The experience with toxicity testing at the Savannah River Site (SRS) has yielded inconclusive data because of the inconsistency and unreliability of the results. The SRS contention is that the WET method in its present form does not adequately mimic actual biological/chemical conditions of the receiving streams and is neither reasonable nor accurate. This paper discusses the rationale for such a position by SRS on toxicity testing in terms of historical permitting requirements, outfall effluent test results, standard test method evaluation, scientific review of alternate test species, and concerns over the test method expressed by other organizations. This paper presents the Savannah River Site

  5. Comments on the sequential probability ratio testing methods

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A. [Hungarian Academy of Sciences, Budapest (Hungary). Central Research Inst. for Physics

    1996-07-01

    In this paper the classical sequential probability ratio testing method (SPRT) is reconsidered. Every individual boundary crossing event of the SPRT is regarded as a new piece of evidence about the problem under hypothesis testing. The Bayes method is applied for belief updating, i.e. integrating these individual decisions. The procedure is recommended to use when the user (1) would like to be informed about the tested hypothesis continuously and (2) would like to achieve his final conclusion with high confidence level. (Author).

  6. INTER LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON

    Science.gov (United States)

    2018-03-26

    data by Instrumentation for Impact  Test , SAE standard J211‐1 [4]. Although the entire curve is collected, the interest of this  project  team  solely...HELMET BLUNT IMPACT TEST METHOD COMPARISON by Tony J. Kayhart Charles A. Hewitt and Jonathan Cyganik March 2018 Final...INTER-LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  7. 40 CFR 63.750 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... method in production on actual production parts or assemblies for a period of time sufficient to coat an... a laboratory or pilot production area, using parts and coatings representative of the process(es) where the alternative method is to be used. The laboratory test will use the same part configuration(s...

  8. Solubility tests and the peripheral blood film method for screening ...

    African Journals Online (AJOL)

    Objective. To determine the cost benefit of screening for sicklecell disease among infants at district health centres in Uganda using sickling, solubility tests and the peripheral blood film method. Methods. Pilot screening services were established at district health centres. Cost benefit analysis (CBA) was performed in four ...

  9. 40 CFR 60.46 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... material balance over the steam generating system shall be used to confirm the rate. (d) The owner or...-Fired Steam Generators for Which Construction Is Commenced After August 17, 1971 § 60.46 Test methods... D2015, or D5865 (solid fuels), D240 (liquid fuels), or D1826 (gaseous fuels) (all of these methods are...

  10. A facile method to enhance the uniformity and adhesion properties of water-based ceramic coating layers on hydrophobic polyethylene separators

    Science.gov (United States)

    Lee, Hoogil; Jeon, Hyunkyu; Gong, Seokhyeon; Ryou, Myung-Hyun; Lee, Yong Min

    2018-01-01

    To enhance the uniformity and adhesion properties of water-based ceramic coating layers on hydrophobic polyethylene (PE) separators, their surfaces were treated with thin and hydrophilic polydopamine layers. As a result, an aqueous ceramic coating slurry consisting of Al2O3 particles, carboxyl methyl cellulose (CMC) binders, and water solvent was easily spread on the separator surface, and a uniform ceramic layer was formed after solvent drying. Moreover, the ceramic coating layer showed greatly improved adhesion properties to the PE separator surface. Whereas the adhesion strength within the bulk coating layer (Fmid) ranged from 43 to 86 N m-1 depending on the binder content of 1.5-3.0 wt%, the adhesion strength at the interface between the ceramic coating layer and PE separator (Fsepa-Al2O3) was 245-360 N m-1, a value equivalent to an increase of four or five times. Furthermore, an additional ceramic coating layer of approximately 7 μm did not degrade the ionic conductivity and electrochemical properties of the bare PE separators. Thus, all the LiMn2O4/graphite cells with ceramic-coated separators delivered an improved cycle life and rate capability compared with those of the control cells with bare PE separators.

  11. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  12. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  13. Comparative study of in-situ filter test methods

    International Nuclear Information System (INIS)

    Marshall, M.; Stevens, D.C.

    1981-01-01

    Available methods of testing high efficiency particulate aerosol (HEPA) filters in-situ have been reviewed. In order to understand the relationship between the results produced by different methods a selection has been compared. Various pieces of equipment for generating and detecting aerosols have been tested and their suitability assessed. Condensation-nuclei, DOP (di-octyl phthalate) and sodium-flame in-situ filter test methods have been studied, using the 500 cfm (9000 m 3 /h) filter test rig at Harwell and in the field. Both the sodium-flame and DOP methods measure the penetration through leaks and filter material. However the measured penetration through filtered leaks depends on the aerosol size distribution and the detection method. Condensation-nuclei test methods can only be used to measure unfiltered leaks since condensation nuclei have a very low penetration through filtered leaks. A combination of methods would enable filtered and unfiltered leaks to be measured. A condensation-nucleus counter using n-butyl alcohol as the working fluid has the advantage of being able to detect any particle up to 1 μm in diameter, including DOP, and so could be used for this purpose. A single-particle counter has not been satisfactory because of interference from particles leaking into systems under extract, particularly downstream of filters, and because the concentration of the input aerosol has to be severely limited. The sodium-flame method requires a skilled operator and may cause safety and corrosion problems. The DOP method using a total light scattering detector has so far been the most satisfactory. It is fairly easy to use, measures reasonably low values of penetration and gives rapid results. DOP has had no adverse effect on HEPA filters over a long series of tests

  14. Controlling of density uniformity of polyacrylate foams

    International Nuclear Information System (INIS)

    Shan Wenwen; Yuan Baohe; Wang Yanhong; Xu Jiayun; Zhang Lin

    2010-01-01

    The density non-uniformity existing in most low-density foams will affect performance of the foams. The trimethylolpropane trimethacrylate (TMPTA) foam targets were prepared and controlling methods of the foams, density uniformity were explored together with its forming mechanism. It has been found that the UV-light with high intensity can improve the distribution uniformity of the free radicals induced by UV photons in the solvents, thus improve the density uniformity of the foams. In addition, container wall would influence the concentration distribution of the solution, which affects the density uniformity of the foams. Thus, the UV-light with high intensity was chosen together with polytetrafluoroethylene molds instead of glass molds to prepare the foams with the density non-uniformity less than 10%. β-ray detection technology was used to measure the density uniformity of the TMPTA foams with the density in the range of 10 to 100 mg · cm -3 , and the results show that the lower the foam density is, the worse the density uniformity is. (authors)

  15. Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a technique for generating data to characterize the kinetics of the release of outgassing products from materials. This technique will determine both the total mass flux evolved by a material when exposed to a vacuum environment and the deposition of this flux on surfaces held at various specified temperatures. 1.2 This test method describes the test apparatus and related operating procedures for evaluating the total mass flux that is evolved from a material being subjected to temperatures that are between 298 and 398 K. Pressures external to the sample effusion cell are less than 7 × 10−3 Pa (5 × 10−5 torr). Deposition rates are measured during material outgassing tests. A test procedure for collecting data and a test method for processing and presenting the collected data are included. 1.3 This test method can be used to produce the data necessary to support mathematical models used for the prediction of molecular contaminant generation, migration, and deposition. 1.4 Al...

  16. Standard Test Methods for Detecting Susceptibility to Intergranular Corrosion in Wrought, Nickel-Rich, Chromium-Bearing Alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover two tests as follows: 1.1.1 Method A, Ferric Sulfate-Sulfuric Acid Test (Sections 3-10, inclusive)—This test method describes the procedure for conducting the boiling ferric sulfate—50 % sulfuric acid test which measures the susceptibility of certain nickel-rich, chromium-bearing alloys to intergranular corrosion (see Terminology G 15), which may be encountered in certain service environments. The uniform corrosion rate obtained by this test method, which is a function of minor variations in alloy composition, may easily mask the intergranular corrosion components of the overall corrosion rate on alloys N10276, N06022, N06059, and N06455. 1.1.2 Method B, Mixed Acid-Oxidizing Salt Test (Sections 11-18, inclusive)—This test method describes the procedure for conducting a boiling 23 % sulfuric + 1.2 % hydrochloric + 1 % ferric chloride + 1 % cupric chloride test which measures the susceptibility of certain nickel-rich, chromium-bearing alloys to display a step function increa...

  17. Test of a method for phase retrieval in HRTEM

    International Nuclear Information System (INIS)

    Beeching, M.J.; Spargo, A.E.C.

    1992-01-01

    Several methods of phase retrieval from the high resolution transmission electron microscopy image intensity distributions have been proposed but no standard method has emerged. The results achieved using a technique based on a development of the focus variation method, are reported. The dependence of the retrieved wavefunction on various experimental parameters is investigated and the method tested using computer simulated images. The method is shown to be useful in finding the complex wavefield at the exit surface of the specimen but the relationship of this to the specimen structure is considered as a separate issue. 1 ref., 3 figs

  18. Testing methods of steel wi re ropes at the anchor

    Directory of Open Access Journals (Sweden)

    Stanislav Kropuch

    2012-12-01

    Full Text Available The present paper introduces an application of the acoustic andthermographic method in the defectoscopic testing of immobilesteel wire ropes at the most critical point, the anchor. Firstmeasurements and their results by these new defectoscopic methodsare shown. In defectoscopic tests at the anchor, the widelyused magnetic method gives unreliable results, and therefore presentsa problem for steel wire defectoscopy. Application of the two new methods in the steel wire defectoscopy at the anchor point will enableincreased safety measures at the anchor of steel wire ropes in bridge, roof, tower and aerial cable lift constructions.

  19. Testing and Validation of the Dynamic Inertia Measurement Method

    Science.gov (United States)

    Chin, Alexander W.; Herrera, Claudia Y.; Spivey, Natalie D.; Fladung, William A.; Cloutier, David

    2015-01-01

    The Dynamic Inertia Measurement (DIM) method uses a ground vibration test setup to determine the mass properties of an object using information from frequency response functions. Most conventional mass properties testing involves using spin tables or pendulum-based swing tests, which for large aerospace vehicles becomes increasingly difficult and time-consuming, and therefore expensive, to perform. The DIM method has been validated on small test articles but has not been successfully proven on large aerospace vehicles. In response, the National Aeronautics and Space Administration Armstrong Flight Research Center (Edwards, California) conducted mass properties testing on an "iron bird" test article that is comparable in mass and scale to a fighter-type aircraft. The simple two-I-beam design of the "iron bird" was selected to ensure accurate analytical mass properties. Traditional swing testing was also performed to compare the level of effort, amount of resources, and quality of data with the DIM method. The DIM test showed favorable results for the center of gravity and moments of inertia; however, the products of inertia showed disagreement with analytical predictions.

  20. ESPRIT And Uniform Linear Arrays

    Science.gov (United States)

    Roy, R. H.; Goldburg, M.; Ottersten, B. E.; Swindlehurst, A. L.; Viberg, M.; Kailath, T.

    1989-11-01

    Abstract ¬â€?ESPRIT is a recently developed and patented technique for high-resolution estimation of signal parameters. It exploits an invariance structure designed into the sensor array to achieve a reduction in computational requirements of many orders of magnitude over previous techniques such as MUSIC, Burg's MEM, and Capon's ML, and in addition achieves performance improvement as measured by parameter estimate error variance. It is also manifestly more robust with respect to sensor errors (e.g. gain, phase, and location errors) than other methods as well. Whereas ESPRIT only requires that the sensor array possess a single invariance best visualized by considering two identical but other-wise arbitrary arrays of sensors displaced (but not rotated) with respect to each other, many arrays currently in use in various applications are uniform linear arrays of identical sensor elements. Phased array radars are commonplace in high-resolution direction finding systems, and uniform tapped delay lines (i.e., constant rate A/D converters) are the rule rather than the exception in digital signal processing systems. Such arrays possess many invariances, and are amenable to other types of analysis, which is one of the main reasons such structures are so prevalent. Recent developments in high-resolution algorithms of the signal/noise subspace genre including total least squares (TLS) ESPRIT applied to uniform linear arrays are summarized. ESPRIT is also shown to be a generalization of the root-MUSIC algorithm (applicable only to the case of uniform linear arrays of omni-directional sensors and unimodular cisoids). Comparisons with various estimator bounds, including CramerRao bounds, are presented.

  1. Women in service uniforms

    OpenAIRE

    Hanna Karaszewska; Maciej Muskała

    2012-01-01

    The article discusses the problems of women who work in the uniformed services with the particular emphasis on the performing of the occupation of the prison service. It presents the legal issues relating to equal treatment of men and women in the workplace, formal factors influencing their employment, the status of women in prison, and the problems of their conducting in the professional role. The article also presents the results of research conducted in Poland and all over the world, on th...

  2. NNWSI waste form test method for unsaturated disposal conditions

    International Nuclear Information System (INIS)

    Bates, J.K.; Gerding, T.J.

    1985-03-01

    A test method has been developed to measure the release of radionuclides from the waste package under simulated NNWSI repository conditions, and to provide information concerning materials interactions that may occur in the repository. Data are presented from Unsaturated testing of simulated Savannah River Laboratory 165 glass completed through 26 weeks. The relationship between these results and those from parametric and analog testing are described. The data indicate that the waste form test is capable of producing consistent, reproducible results that will be useful in evaluating the role of the waste package in the long-term performance of the repository. 6 refs., 7 figs., 5 tabs

  3. Discontinuous Petrov-Galerkin method based on the optimal test space norm for one-dimensional transport problems

    KAUST Repository

    Niemi, Antti

    2011-05-14

    We revisit the finite element analysis of convection dominated flow problems within the recently developed Discontinuous Petrov-Galerkin (DPG) variational framework. We demonstrate how test function spaces that guarantee numerical stability can be computed automatically with respect to the so called optimal test space norm by using an element subgrid discretization. This should make the DPG method not only stable but also robust, that is, uniformly stable with respect to the Ṕeclet number in the current application. The e_ectiveness of the algorithm is demonstrated on two problems for the linear advection-di_usion equation.

  4. Valid methods: the quality assurance of test method development, validation, approval, and transfer for veterinary testing laboratories.

    Science.gov (United States)

    Wiegers, Ann L

    2003-07-01

    Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.

  5. Testing and Validation of Computational Methods for Mass Spectrometry.

    Science.gov (United States)

    Gatto, Laurent; Hansen, Kasper D; Hoopmann, Michael R; Hermjakob, Henning; Kohlbacher, Oliver; Beyer, Andreas

    2016-03-04

    High-throughput methods based on mass spectrometry (proteomics, metabolomics, lipidomics, etc.) produce a wealth of data that cannot be analyzed without computational methods. The impact of the choice of method on the overall result of a biological study is often underappreciated, but different methods can result in very different biological findings. It is thus essential to evaluate and compare the correctness and relative performance of computational methods. The volume of the data as well as the complexity of the algorithms render unbiased comparisons challenging. This paper discusses some problems and challenges in testing and validation of computational methods. We discuss the different types of data (simulated and experimental validation data) as well as different metrics to compare methods. We also introduce a new public repository for mass spectrometric reference data sets ( http://compms.org/RefData ) that contains a collection of publicly available data sets for performance evaluation for a wide range of different methods.

  6. The test of intrinsic uniformity is one of the basic tests to check the status of the detectors of gamma cameras, and as such is contained in RD 1 841/1997 Quality Control in Nuclear Medicine; Protocolo NEMA para el calculo de la uniformidad intrinsica en gamma-camaras: aplicacion y comparacion con el software del fabricante

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Soto, X. L.; Gonzalez Ruiz, C.; Lopez-Boto, M. A.; Polo Cezon, R.

    2015-07-01

    Spanish Protocol Quality Control Instrumentation in Nuclear Medicine provides guidelines for conducting this test, similar to those established in the NEMA protocol NEMA Protocol for the calculation of the uniformity intrinsic in GAMMA cameras: application and comparison with the SQFTWARE of the manufacturer. it is advisable to conduct a study to ensure that the results for the test of intrinsic uniformity of the software provided by the equipment manufacturer are equivalent to those obtained by applying the protocol recommended by the SEFM before using this software for performing quality control. (Author)

  7. Interesting Developments in Testing Methods Applied to Foundation Piles

    Science.gov (United States)

    Sobala, Dariusz; Tkaczyński, Grzegorz

    2017-10-01

    Both: piling technologies and pile testing methods are a subject of current development. New technologies, providing larger diameters or using in-situ materials, are very demanding in terms of providing proper quality of execution of works. That concerns the material quality and continuity which define the integral strength of pile. On the other side we have the capacity of the ground around the pile and its ability to carry the loads transferred by shaft and pile base. Inhomogeneous nature of soils and a relatively small amount of tested piles imposes very good understanding of small amount of results. In some special cases the capacity test itself form an important cost in the piling contract. This work presents a brief description of selected testing methods and authors remarks based on cooperation with Universities constantly developing new ideas. Paper presents some experience based remarks on integrity testing by means of low energy impact (low strain) and introduces selected (Polish) developments in the field of closed-end pipe piles testing based on bi-directional loading, similar to Osterberg idea, but without sacrificial hydraulic jack. Such test is suitable especially when steel piles are used for temporary support in the rivers, where constructing of conventional testing appliance with anchor piles or kentledge meets technical problems. According to the author’s experience, such tests were not yet used on the building site but they bring a real potential especially, when the displacement control can be provided from the river bank using surveying techniques.

  8. Verification methods for treaties limiting and banning nuclear tests

    International Nuclear Information System (INIS)

    Voloshin, N.P.

    1998-01-01

    Treaty on limitation of underground nuclear weapon tests and treaty on world banning of nuclear tests contribute to and accompany the process of nuclear disarmament. Test ban in three (Moscow treaty of 1963) as well as the Threshold Test Ban up to 1991 was controlled only with national means. But since 1991 nuclear test threshold of 150 kt has been measured with hydrodynamic and tele seismic methods and checked by the inspection. Distinctive feature of this control is that control is that it is bilateral. This conforms to Treaty on limitation of underground nuclear weapon tests signed by two countries - USA and USSR. The inspection at the place of tests requires monitoring of the test site of the party conducting a test and geological information of rock in the area of explosion. In the treaty of the World Nuclear Test Ban the following ways of international control are provided for: - seismologic measurements; - radionuclide measurements; - hydro-acoustics measurements; - infra-sound measurements; - inspection at the place of the tests conduction

  9. Application of the autoradiography method for study of the Semipalatinsk test site's lichens

    International Nuclear Information System (INIS)

    Ajdarkhanova, G.S.; Poltavtseva, V.P.

    2003-01-01

    The preliminary results of the Semipalatinsk test site's lichens study with help of the autoradiography method are presented. The lichens selected in 1999 on the experimental sites situated in two areas (20 km southerly from Kurchatov town and on of the Degelen mountain south side) have served as the examined objects. Radiation background of the lichens dwelling areas make up 15-17 and 300 μR/h respectively. For receiving of autoradiograms the FT-41MD film with two-side emulsion layer was used. Exposition time is 48 and 744 hours. From visual analysis of photographic image with this autoradiogram one can draw the conclusion about uniform distribution of the radionuclides. Received results testify about the necessity for continuance of the researches in this direction with expansion lichen species content and geography of their scattering

  10. Comparative study of durability test methods for pellets and briquettes

    Energy Technology Data Exchange (ETDEWEB)

    Temmerman, Michaeel; Rabier, Fabienne [Centre wallon de Recherches agronomiques (CRA-W), 146, chaussee de Namur, B-5030, Gembloux (Belgium); Jensen, Peter Daugbjerg [Forest and Landscape, The Royal Veterinary and Agricultural University, Rolighedsvej 23, DK-1958 Frederiksberg C (Denmark); Hartmann, Hans; Boehm, Thorsten [Technologie- und Foerderzentrum fuer Nachwachsende Rohstoffe-TFZ, Schulgasse 18, D-94315 Straubing (Germany)

    2006-11-15

    Different methods for the determination of the mechanical durability (DU) of pellets and briquettes were compared by international round robin tests including different laboratories. The DUs of five briquette and 26 pellet types were determined. For briquettes, different rotation numbers of a prototype tumbler and a calculated DU index are compared. For pellets testing, the study compares two standard methods, a tumbling device according to ASAE S 269.4, the Lignotester according to ONORM M 7135 and a second tumbling method with a prototype tumbler. For the tested methods, the repeatability, the reproducibility and the required minimum number of replications to achieve given accuracy levels were calculated. Additionally, this study evaluates the relation between DU and particle density. The results show for both pellets and briquettes, that the measured DU values and their variability are influenced by the applied method. Moreover, the variability of the results depend on the biofuel itself. For briquettes of DU above 90%, five replications lead to an accuracy of 2%, while 39 replications are needed to achieve an accuracy of 10%, when briquettes of DU below 90% are tested. For pellets, the tumbling device described by the ASAE standard allows to reach acceptable accuracy levels (1%) with a limited number of replications. Finally, for the tested pellets and briquettes no relation between DU and particle density was found. (author)

  11. Applicability and interpretation of fracture test methods for metals

    International Nuclear Information System (INIS)

    Langford, W.J.

    1978-05-01

    Fracture tests are conducted usually out of a conviction (sometimes only vaguely defined) that they will guarantee a certain level of protecton from metal failure. Qualitative tests, such as the Charpy V-notch, produce results which cannot be rigorously related to a measure of fracture tolerance: rather, they indicate metal quality so that fracture tolerance may be inferred. Quantitative tests on the other hand provide parameters which may be used directly in equations to determine the likelihood of fracture. Both types of tests have limitations which should be understood: the paper tries to provide guidance on the relative merits of either approach for a particular purpose, and gives an insight into near-future test methods which will extend the range of usefullness of quantitative tests. (author)

  12. Antifungal susceptibility testing method for resource constrained laboratories

    Directory of Open Access Journals (Sweden)

    Khan S

    2006-01-01

    Full Text Available Purpose: In resource-constrained laboratories of developing countries determination of antifungal susceptibility testing by NCCLS/CLSI method is not always feasible. We describe herein a simple yet comparable method for antifungal susceptibility testing. Methods: Reference MICs of 72 fungal isolates including two quality control strains were determined by NCCLS/CLSI methods against fluconazole, itraconazole, voriconazole, amphotericin B and cancidas. Dermatophytes were also tested against terbinafine. Subsequently, on selection of optimum conditions, MIC was determined for all the fungal isolates by semisolid antifungal agar susceptibility method in Brain heart infusion broth supplemented with 0.5% agar (BHIA without oil overlay and results were compared with those obtained by reference NCCLS/CLSI methods. Results: Comparable results were obtained by NCCLS/CLSI and semisolid agar susceptibility (SAAS methods against quality control strains. MICs for 72 isolates did not differ by more than one dilution for all drugs by SAAS. Conclusions: SAAS using BHIA without oil overlay provides a simple and reproducible method for obtaining MICs against yeast, filamentous fungi and dermatophytes in resource-constrained laboratories.

  13. Standard Test Methods for Determining Mechanical Integrity of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover procedures for determining the ability of photovoltaic modules to withstand the mechanical loads, stresses and deflections used to simulate, on an accelerated basis, high wind conditions, heavy snow and ice accumulation, and non-planar installation effects. 1.1.1 A static load test to 2400 Pa is used to simulate wind loads on both module surfaces 1.1.2 A static load test to 5400 Pa is used to simulate heavy snow and ice accumulation on the module front surface. 1.1.3 A twist test is used to simulate the non-planar mounting of a photovoltaic module by subjecting it to a twist angle of 1.2°. 1.1.4 A cyclic load test of 10 000 cycles duration and peak loading to 1440 Pa is used to simulate dynamic wind or other flexural loading. Such loading might occur during shipment or after installation at a particular location. 1.2 These test methods define photovoltaic test specimens and mounting methods, and specify parameters that must be recorded and reported. 1.3 Any individual mech...

  14. A RICH with aerogel: a study of refractive index uniformity

    CERN Document Server

    Alemi, M; Calvi, M; Matteuzzi, C; Musy, M; Perego, D L; Easo, S

    2004-01-01

    The use of aerogel as a radiator in the RICH detectors of LHCb is a challenge due to the hot environment of the hadron collider LHC. Large size tiles of silica aerogel were recently produced with unprecedented optical quality for such dimensions. Results of laboratory measurements and beam tests are briefly reported. A description of a method to measure the uniformity of the index of refraction within the tile is given.

  15. Test cases for interface tracking methods: methodology and current status

    International Nuclear Information System (INIS)

    Lebaigue, O.; Jamet, D.; Lemonnier, E.

    2004-01-01

    Full text of publication follows:In the past decade, a large number of new methods have been developed to deal with interfaces in the numerical simulation of two-phase flows. We have collected a set of 36 test cases, which can be seen as a tool to help engineers and researchers selecting the most appropriate method(s) for their specific fields of application. This set can be use: - To perform an initial evaluation of the capabilities of available methods with regard to the specificity of the final application and the most important features to be recovered from the simulation. - To measure the maximum mesh size to be used for a given physical problem in order to obtain an accurate enough solution. - To assess and quantify the performances of a selected method equipped with its set of physical models. The computation of a well-documented test case allows estimating the error due to the numerical technique by comparison with reference solutions. This process is compulsory to gain confidence and credibility on the prediction capabilities of a numerical method and its physical models. - To broaden the capabilities of a given numerical technique. The test cases may be used to identify the need for improvement of the overall numerical scheme or to determine the physical part of the model, which is responsible for the observed limitations. Each test case falls within one of the following categories: - Analytical solutions of well-known sets of equations corresponding to simple geometrical situations. - Reference numerical solutions of moderately complex problems, produced by accurate methods (e.g., boundary Fitted coordinate method) on refined meshes. - Separate effects analytical experiments. The presentation will suggest how to use the test cases for assessing the physical models and the numerical methods. The expected fallout of using test cases is indeed on the one hand to identify the merits of existing methods and on the other hand to orient further research towards

  16. Standard Test Methods for Constituent Content of Composite Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods determine the constituent content of composite materials by one of two approaches. Method I physically removes the matrix by digestion or ignition by one of seven procedures, leaving the reinforcement essentially unaffected and thus allowing calculation of reinforcement or matrix content (by weight or volume) as well as percent void volume. Method II, applicable only to laminate materials of known fiber areal weight, calculates reinforcement or matrix content (by weight or volume), and the cured ply thickness, based on the measured thickness of the laminate. Method II is not applicable to the measurement of void volume. 1.1.1 These test methods are primarily intended for two-part composite material systems. However, special provisions can be made to extend these test methods to filled material systems with more than two constituents, though not all test results can be determined in every case. 1.1.2 The procedures contained within have been designed to be particularly effective for ce...

  17. A novel test tube method of screening for hemoglobin E.

    Science.gov (United States)

    Tatu, T; Kasinrerk, W

    2012-02-01

    Hemoglobin (Hb) E is a β-structural variant common worldwide. This Hb disorder can form a compound heterozygous state with the β-thalassemia gene, leading to life-threatening hereditary hemolytic anemia, HbE/β-thalassemia. Screening of HbE has proven to be a challenging practice in prevention and control of the HbE/β-thalassemia. A novel test tube method for HbE screening using diethyl aminoethyl (DEAE)-cellulose resin was described. With the developed system, HbE/A(2) did not bind to the resin and remained dissolved in the supernatant, whereas other Hbs completely bound to the resin. The red color of the supernatant observed in the test tube indicated the presence of HbE. Colorless or markedly pale color of the supernatant indicates the absence of HbE. Accuracy and efficiency of the established method in detecting HbE was comparable with the standard cellulose acetate electrophoresis method. The developed method is cheap and simple with no requirement of sophisticated equipment. The reagent could be stored at 4 °C for up to 5 months. Hemolysate samples aged up to 5 months were still suitable for this test. The described novel test tube method could be an alternative method of mass population screening for HbE, particularly in small health care facilities. © 2011 Blackwell Publishing Ltd.

  18. Trajectory planning and test for all coverage, automatic and uniform feeding in river crab aquaculture%河蟹养殖全覆盖自动均匀投饲的轨迹规划与试验

    Institute of Scientific and Technical Information of China (English)

    孙月平; 赵德安; 洪剑青; 张军; 李发忠; 罗吉

    2016-01-01

    of optimal calculation trajectory planning were better than that of traditional empirical estimation trajectory planning when feeding system worked with the parameters respectively. For the optimal calculation trajectory planning, corresponding total path length was 235.39 m, feeding path length was 195.16 m, total working time was 789.10 s, feed average density was 8.85 g/m2, and feeding coverage rate was 86.84%. Feeding contrast tests between traditional empirical estimation trajectory planning and optimal calculation trajectory planning were performed in Jiangsu University in April 2016. Results showed that experimental trajectories of workboat using the 2 groups of parameters both had only small offsets with the planned trajectories, which were consistent with the simulation results, and all feeding performance indices of optimal calculation trajectory planning were better than that of traditional empirical estimation trajectory planning. For the optimal calculation trajectory planning, corresponding practical total path length was 251.52 m, feeding path length was 200.45 m, total working time was 868.5 s, feeding time was 501.1 s, feed average density was 8.58 g/m2, and feeding coverage rate was 88.46%. And the relative error was 6.85%, 2.71%, 10.07%, 10.41%, 3.06% and 1.87% when comparing with the simulation results respectively, which showed the feasibility of the coverage trajectory planning method. Furthermore, trajectory planning verification simulation on another larger river crab pond of 15 057.56 m2 was performed, which corroborated that the automatic coverage trajectory planning system was also effective and applicable for large area river crab pond. The system could generate feeding trajectory directly and automatically when getting vertex coordinates of pond area, which would improve the accuracy and efficiency of trajectory planning, guarantee the uniform feeding and increase the economic benefits. This research provides technology reference for

  19. Barriers to Implementing a Single Joint Combat Camouflage Uniform

    Science.gov (United States)

    2017-12-01

    opportunities, threats (SWOT), and political, economic, social, and technological (PEST) analyses; examines the requirements and role of each of the...SUBJECT TERMS ground combat uniform, combat camouflage uniform history , combat camouflage uniform pattern, camouflage pattern testing 15. NUMBER...methodology applies strengths, weaknesses, opportunities, threats (SWOT), and political, economic, social, and technological (PEST) analyses

  20. [Testing methods for seed quality of Bletilla striata].

    Science.gov (United States)

    Zhang, Zhi-Hui; Liu, Da-Hui; Zhu, Xin-Yan; Ji, Peng-Zhang; Wang, Li; Shi, Ya-Na; Ma, Cong-Ji

    2016-06-01

    In order to provide a basis for establishing seed testing rules and seed quality standard of Bletilla striata, the seed quality of B.striata from different producing area was measured referring to the Rules for Agricultural Seed Testing(GB/T 3543-1995).The results showed that the seeds of B.striata passed through 20-mesh sieve for purity analysis.The weight of seeds was measured by 1000-seed method and the water content was measured at the higher temperature (133±2) ℃ for 3 hours.The seeds were cultured on the wet filter paper at 30 ℃ for 4-20 days in light for germination testing.The method of testing seed viability was that seeds were dipped into 1% TTC solution for 7 hours at temperature of 40 ℃. Copyright© by the Chinese Pharmaceutical Association.

  1. Critical wall shear stress for the EHEDG test method

    DEFF Research Database (Denmark)

    Jensen, Bo Boye Busk; Friis, Alan

    2004-01-01

    In order to simulate the results of practical cleaning tests on closed processing equipment, based on wall shear stress predicted by computational fluid dynamics, a critical wall shear stress is required for that particular cleaning method. This work presents investigations that provide a critical...... wall shear stress of 3 Pa for the standardised EHEDG cleaning test method. The cleaning tests were performed on a test disc placed in a radial flowcell assay. Turbulent flow conditions were generated and the corresponding wall shear stresses were predicted from CFD simulations. Combining wall shear...... stress predictions from a simulation using the low Re k-epsilon and one using the two-layer model of Norris and Reynolds were found to produce reliable predictions compared to empirical solutions for the ideal flow case. The comparison of wall shear stress curves predicted for the real RFC...

  2. ASTM F739 method for testing the permeation resistance of protective clothing materials: critical analysis with proposed changes in procedure and test-cell design.

    Science.gov (United States)

    Anna, D H; Zellers, E T; Sulewski, R

    1998-08-01

    ASTM (American Society for Testing and Materials) Method F739-96 specifies a test-cell design and procedures for measuring the permeation resistance of chemical protective clothing. Among the specifications are open-loop collection stream flow rates of 0.050 to 0.150 L/min for a gaseous medium. At elevated temperatures the test must be maintained within 1 degree C of the set point. This article presents a critical analysis of the effect of the collection stream flow rate on the measured permeation rate and on the temperature uniformity within the test cell. Permeation tests were conducted on four polymeric glove materials with 44 solvents at 25 degrees C. Flow rates > 0.5 L/min were necessary to obtain accurate steady-state permeation rate (SSPR) values in 25 percent of the tests. At the lower flow rates the true SSPR typically was underestimated by a factor of two or less, but errors of up to 33-fold were observed. No clear relationship could be established between the need for a higher collection stream flow rate and either the vapor pressure or the permeation rate of the solvent, but test results suggest that poor mixing within the collection chamber was a contributing factor. Temperature gradients between the challenge and collection chambers and between the bottom and the top of the collection chamber increased with the water-bath temperature and the collection stream flow rate. Use of a test cell modified to permit deeper submersion reduced the gradients to < or = 0.5 degrees C. It is recommended that all SSPR measurements include verification of the adequacy of the collection stream flow rate. For testing at nonambient temperatures, the modified test cell described here could be used to ensure temperature uniformity throughout the cell.

  3. Alternative containment integrity test methods, an overview of possible techniques

    International Nuclear Information System (INIS)

    Spletzer, B.L.

    1986-01-01

    A study is being conducted to develop and analyze alternative methods for testing of containment integrity. The study is focused on techniques for continuously monitoring containment integrity to provide rapid detection of existing leaks, thus providing greater certainty of the integrity of the containment at any time. The study is also intended to develop techniques applicable to the currently required Type A integrated leakage rate tests. A brief discussion of the range of alternative methods currently being considered is presented. The methods include applicability to all major containment types, operating and shutdown plant conditions, and quantitative and qualitative leakage measurements. The techniques are analyzed in accordance with the current state of knowledge of each method. The bulk of the techniques discussed are in the conceptual stage, have not been tested in actual plant conditions, and are presented here as a possible future direction for evaluating containment integrity. Of the methods considered, no single method provides optimum performance for all containment types. Several methods are limited in the types of containment for which they are applicable. The results of the study to date indicate that techniques for continuous monitoring of containment integrity exist for many plants and may be implemented at modest cost

  4. Advantages and limitations of common testing methods for antioxidants.

    Science.gov (United States)

    Amorati, R; Valgimigli, L

    2015-05-01

    Owing to the importance of antioxidants in the protection of both natural and man-made materials, a large variety of testing methods have been proposed and applied. These include methods based on inhibited autoxidation studies, which are better followed by monitoring the kinetics of oxygen consumption or of the formation of hydroperoxides, the primary oxidation products. Analytical determination of secondary oxidation products (e.g. carbonyl compounds) has also been used. The majority of testing methods, however, do not involve substrate autoxidation. They are based on the competitive bleaching of a probe (e.g. ORAC assay, β-carotene, crocin bleaching assays, and luminol assay), on reaction with a different probe (e.g. spin-trapping and TOSC assay), or they are indirect methods based on the reduction of persistent radicals (e.g. galvinoxyl, DPPH and TEAC assays), or of inorganic oxidizing species (e.g. FRAP, CUPRAC and Folin-Ciocalteu assays). Yet other methods are specific for preventive antioxidants. The relevance, advantages, and limitations of these methods are critically discussed, with respect to their chemistry and the mechanisms of antioxidant activity. A variety of cell-based assays have also been proposed, to investigate the biological activity of antioxidants. Their importance and critical aspects are discussed, along with arguments for the selection of the appropriate testing methods according to the different needs.

  5. An accelerated test method for efflorescence in clay bricks

    International Nuclear Information System (INIS)

    Beggan, John Edward

    1998-01-01

    An investigation into the creation of accelerated efflorescence in clay bricks was undertaken with a view to creating a viable test procedure for determining efflorescence potential. The testing programme incorporated ambient conditions similar to those which promote efflorescence growth in bricks in use. Theoretical investigations into the physical mechanism underlying the creation of efflorescence directed the attempts to accelerate the process. It was found that calcium sulphate efflorescence could not be sufficiently accelerated such that a useful efflorescence test procedure could be proposed. The inability to produce accelerated efflorescence in brick samples was attributed to limitations associated with time dependent salt diffusion in the efflorescence mechanism. The preliminary testing that was undertaken into the creation of efflorescence prompted the use of acid assisted methods to accelerate efflorescence. The acid assisted method that was adopted to provide a possible indication of efflorescence potential relies upon the transformation of low solubility calcium to a more soluble form. The movement of the transformed salt is then induced by cyclic temperature exposure at temperatures similar to those experienced in Spring. The appearance of the transformed calcium salt on the surface of the brick specimen provides an indication of the efflorescence potential. Brick piers constructed on an exposed site and monitored over a 12 month period provided information on the validity of the acid assisted test method. The efflorescence observed on the piers correlated well with that predicted by the acid assisted test, suggesting that the new test has the potential to accurately predict the efflorescence potential of clay bricks Relationships between other properties such as air permeability, sorptivity and tensile strength were investigated such that an alternative method of predicting efflorescence could be achieved. It was found that (within the bounds of the

  6. Testing methods of ECR ion source experimental platform

    International Nuclear Information System (INIS)

    Zhou Changgeng; Hu Yonghong; Li Yan

    2006-12-01

    The principle and structure of ECR ion source experimental platform were introduce. The testing methods of the parameters of single main component and the comprehensive parameters under the condition of certain beam current and beam spot diameter were summarized in process of manufacturing. Some appropriate testing dates were given. The existent questions (the parameters of plasma density in discharge chamber and accurate hydrogen flow, etc. can not be measured in operation) and resolutions were also put forward. (authors)

  7. Towards Automatic Testing of Reference Point Based Interactive Methods

    OpenAIRE

    Ojalehto, Vesa; Podkopaev, Dmitry; Miettinen, Kaisa

    2016-01-01

    In order to understand strengths and weaknesses of optimization algorithms, it is important to have access to different types of test problems, well defined performance indicators and analysis tools. Such tools are widely available for testing evolutionary multiobjective optimization algorithms. To our knowledge, there do not exist tools for analyzing the performance of interactive multiobjective optimization methods based on the reference point approach to communicating ...

  8. A model based security testing method for protocol implementation.

    Science.gov (United States)

    Fu, Yu Long; Xin, Xiao Long

    2014-01-01

    The security of protocol implementation is important and hard to be verified. Since the penetration testing is usually based on the experience of the security tester and the specific protocol specifications, a formal and automatic verification method is always required. In this paper, we propose an extended model of IOLTS to describe the legal roles and intruders of security protocol implementations, and then combine them together to generate the suitable test cases to verify the security of protocol implementation.

  9. Gain uniformity experimental study performed on triple-GEM gas detector

    International Nuclear Information System (INIS)

    Dong Liyuan; Qi Huirong; Lu Xinyu; Ouyang Qun; Chen Yuanbo; Li Yuhong

    2012-01-01

    With the application of the two-dimensional GEM gaseous detector in X-ray imaging, the correction method of gain uniformity caused by triple-GEM avalanche structures and electric field uniformity should be studied. The paper reported the study of the triple-GEM detector with effective area 100 mm × 100 mm used the Pad's size of 9.5 mm × 9.5 mm. In the test, 100 readout channels were designed. Results showed that gain remained stable over time; at air flow increases, gain from increases obviously to changes very little. Particularly, triple-GEM's gain uniformity was very good (more than 80%) and the range of energy resolution was from 0.18 to 0.2. To improve gain consistency of results, the difference value revised was obtained to be about 0.1 by the least square method. It provided a better method to improve gain uniformity of GEM detector. (authors)

  10. Standard Test Method for Normal Spectral Emittance at Elevated Temperatures

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1972-01-01

    1.1 This test method describes a highly accurate technique for measuring the normal spectral emittance of electrically conducting materials or materials with electrically conducting substrates, in the temperature range from 600 to 1400 K, and at wavelengths from 1 to 35 μm. 1.2 The test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is suitable for research laboratories where the highest precision and accuracy are desired, but is not recommended for routine production or acceptance testing. However, because of its high accuracy this test method can be used as a referee method to be applied to production and acceptance testing in cases of dispute. 1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this stan...

  11. Test methods for determining asphaltene stability in crude oils

    Energy Technology Data Exchange (ETDEWEB)

    Asomaning, S. [Baker Petrolite, Sugar Land, TX (United States)

    2001-07-01

    The development of test methods for the determination of the stability of asphaltenes in crude oils was rendered necessary, due to the high cost of remediating asphaltene deposition in harsh production environments, namely the underwater systems in offshore deepwater. The Oliensis Spot Test, two saturates, aromatics, resins and asphaltenes (SARA)-based screens (the Colloidal Instability Index and Asphaltene-Resin ratio), a solvent titration method with near infrared radiation (NIR) solids detection, and live oil depressurization were used for the purposes of this study, to predict the stability of asphaltenes in crude oils with different API gravity. A complete description of the test methods was provided, and the experimental data obtained as a result was presented. Correlation with data on the deposition histories of the oils was used to validate the experimental stability data. The author discussed the effectiveness of the different tests for the prediction of the stability of asphaltenes in crude oils. The prediction of a crude oil's propensity towards asphaltene precipitation was more accurate with the Colloidal Instability Index and the solvent titration method. Live oil depressurization proved to be very effective for the prediction of the stability of asphaltenes for light oils, where most stability tests fail. tabs., 31 figs.

  12. Evaluation of clinical methods for peroneal muscle testing.

    Science.gov (United States)

    Sarig-Bahat, Hilla; Krasovsky, Andrei; Sprecher, Elliot

    2013-03-01

    Manual muscle testing of the peroneal muscles is well accepted as a testing method in musculoskeletal physiotherapy for the assessment of the foot and ankle. The peroneus longus and brevis are primary evertors and secondary plantar flexors of the ankle joint. However, some international textbooks describe them as dorsi flexors, when instructing peroneal muscle testing. The identified variability raised a question whether these educational texts are reflected in the clinical field. The purposes of this study were to investigate what are the methods commonly used in the clinical field for peroneal muscle testing and to evaluate their compatibility with functional anatomy. A cross-sectional study was conducted, using an electronic questionnaire sent to 143 Israeli physiotherapists in the musculoskeletal field. The survey questioned on the anatomical location of manual resistance and the combination of motions resisted. Ninety-seven responses were received. The majority (69%) of respondents related correctly to the peronei as evertors, but asserted that resistance should be located over the dorsal aspect of the fifth metatarsus, thereby disregarding the peroneus longus. Moreover, 38% of the respondents described the peronei as dorsi flexors, rather than plantar flexors. Only 2% selected the correct method of resisting plantarflexion and eversion at the base of the first metatarsus. We consider this technique to be the most compatible with the anatomy of the peroneus longus and brevis. The Fisher-Freeman-Halton test indicated that there was a significant relationship between responses on the questions (P = 0.0253, 95% CI 0.0249-0.0257), thus justifying further correspondence analysis. The correspondence analysis found no clustering of the answers that were compatible with anatomical evidence and were applied in the correct technique, but did demonstrate a common error, resisting dorsiflexion rather than plantarflexion, which was in agreement with the described

  13. A Fuzzy Logic Based Method for Analysing Test Results

    Directory of Open Access Journals (Sweden)

    Le Xuan Vinh

    2017-11-01

    Full Text Available Network operators must perform many tasks to ensure smooth operation of the network, such as planning, monitoring, etc. Among those tasks, regular testing of network performance, network errors and troubleshooting is very important. Meaningful test results will allow the operators to evaluate network performanceof any shortcomings and to better plan for network upgrade. Due to the diverse and mainly unquantifiable nature of network testing results, there is a needs to develop a method for systematically and rigorously analysing these results. In this paper, we present STAM (System Test-result Analysis Method which employs a bottom-up hierarchical processing approach using Fuzzy logic. STAM is capable of combining all test results into a quantitative description of the network performance in terms of network stability, the significance of various network erros, performance of each function blocks within the network. The validity of this method has been successfully demonstrated in assisting the testing of a VoIP system at the Research Instiute of Post and Telecoms in Vietnam. The paper is organized as follows. The first section gives an overview of fuzzy logic theory the concepts of which will be used in the development of STAM. The next section describes STAM. The last section, demonstrating STAM’s capability, presents a success story in which STAM is successfully applied.

  14. Application of the X-in-the-Loop Testing Method in the FCV Hybrid Degree Test

    Directory of Open Access Journals (Sweden)

    Haiyu Gao

    2018-02-01

    Full Text Available With the development of fuel cell vehicle technology, an effective testing method that can be applied to develop and verify the fuel cell vehicle powertrain system is urgently required. This paper presents the X-in-the-Loop (XiL testing method in the fuel cell vehicle (FCV hybrid degree test to resolve the first and key issues for the powertrain system design, and the test process and scenarios were designed. The hybrid degree is redefined into the static hybrid degree for system architecture design and the dynamic hybrid degree for vehicle control strategy design, and an integrated testing platform was introduced and a testing application was implemented by following the designed testing flowchart with two loops. Experimental validations show that the sizing of the FCE (Fuel Cell Engine, battery pack, and traction motor with the powertrain architecture can be determined, the control strategy can be evaluated seamlessly, and a systematic powertrain testing solution can be achieved through the whole development process. This research has developed a new testing platform and proposed a novel testing method on the fuel cell vehicle powertrain system, which will be a contribution to fuel cell vehicle technology and its industrialization.

  15. Standard Test Method for Measuring Binocular Disparity in Transparent Parts

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers the amount of binocular disparity that is induced by transparent parts such as aircraft windscreens, canopies, HUD combining glasses, visors, or goggles. This test method may be applied to parts of any size, shape, or thickness, individually or in combination, so as to determine the contribution of each transparent part to the overall binocular disparity present in the total “viewing system” being used by a human operator. 1.2 This test method represents one of several techniques that are available for measuring binocular disparity, but is the only technique that yields a quantitative figure of merit that can be related to operator visual performance. 1.3 This test method employs apparatus currently being used in the measurement of optical angular deviation under Method F 801. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not con...

  16. Testing of VVER reactor pressure vessels by TOFD method

    International Nuclear Information System (INIS)

    Skala, Z.; Vit, J.

    2002-01-01

    The Time of Flight Diffraction Method (TOFD) - one of the new testing methods capable to obtain the real dimensions of flaws - is presented in the paper.The laboratory experiments on samples with artificial flaws and samples with artificially prepared cracks confirmed the high accuracy of flaw through wall extent sizing by TOFD. This accuracy was confirmed by qualification of methods and systems used by Skoda JS for the in-service inspections of WWER 440 vessel circumferential weld. The qualification also confirmed the ability of TOFD to detect reliably flaws, which can are not reliably detected by standard pulse echo testing. Based on the result of experiments and qualification, the TOFD method shall be used routinely by Skoda JS for the inspection of vessel circumferential welds root area and for sizing of flaws exceeding the acceptance level

  17. An analytic data analysis method for oscillatory slug tests.

    Science.gov (United States)

    Chen, Chia-Shyun

    2006-01-01

    An analytical data analysis method is developed for slug tests in partially penetrating wells in confined or unconfined aquifers of high hydraulic conductivity. As adapted from the van der Kamp method, the determination of the hydraulic conductivity is based on the occurrence times and the displacements of the extreme points measured from the oscillatory data and their theoretical counterparts available in the literature. This method is applied to two sets of slug test response data presented by Butler et al.: one set shows slow damping with seven discernable extremities, and the other shows rapid damping with three extreme points. The estimates of the hydraulic conductivity obtained by the analytic method are in good agreement with those determined by an available curve-matching technique.

  18. Women in service uniforms

    Directory of Open Access Journals (Sweden)

    Hanna Karaszewska

    2012-12-01

    Full Text Available The article discusses the problems of women who work in the uniformed services with the particular emphasis on the performing of the occupation of the prison service. It presents the legal issues relating to equal treatment of men and women in the workplace, formal factors influencing their employment, the status of women in prison, and the problems of their conducting in the professional role. The article also presents the results of research conducted in Poland and all over the world, on the functioning of women in prison and their relations with officers of the Prison Service, as well as with inmates.

  19. Uniform gradient expansions

    CERN Document Server

    Giovannini, Massimo

    2015-01-01

    Cosmological singularities are often discussed by means of a gradient expansion that can also describe, during a quasi-de Sitter phase, the progressive suppression of curvature inhomogeneities. While the inflationary event horizon is being formed the two mentioned regimes coexist and a uniform expansion can be conceived and applied to the evolution of spatial gradients across the protoinflationary boundary. It is argued that conventional arguments addressing the preinflationary initial conditions are necessary but generally not sufficient to guarantee a homogeneous onset of the conventional inflationary stage.

  20. Instrumentation and measurement method for the ATLAS test facility

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Byong Jo; Chu, In Chul; Eu, Dong Jin; Kang, Kyong Ho; Kim, Yeon Sik; Song, Chul Hwa; Baek, Won Pil

    2007-03-15

    An integral effect test loop for pressurized water reactors (PWRs), the ATLAS is constructed by thermal-hydraulic safety research division in KAERI. The ATLAS facility has been designed to have the length scale of 1/2 and area scale of 1/144 compared with the reference plant, APR1400 which is a Korean evolution type nuclear reactors. A total 1300 instrumentations is equipped in the ATLAS test facility. In this report, the instrumentation of ATLAS test facility and related measurement methods were introduced.

  1. MCC-15: waste/canister accident testing and analysis method

    International Nuclear Information System (INIS)

    Slate, S.C.; Pulsipher, B.A.; Scott, P.A.

    1985-02-01

    The Materials Characterization Center (MCC) at the Pacific Northwest Laboratory (PNL) is developing standard tests to characterize the performance of nuclear waste forms under normal and accident conditions. As part of this effort, the MCC is developing MCC-15, Waste/Canister Accident Testing and Analysis. MCC-15 is used to test canisters containing simulated waste forms to provide data on the effects of accidental impacts on the waste form particle size and on canister integrity. The data is used to support the design of transportation and handling equipment and to demonstrate compliance with repository waste acceptance specifications. This paper reviews the requirements that led to the development of MCC-15, describes the test method itself, and presents some early results from tests on canisters representative of those proposed for the Defense Waste Processing Facility (DWPF). 13 references, 6 figures

  2. Apparatus and method for defect testing of integrated circuits

    Science.gov (United States)

    Cole, Jr., Edward I.; Soden, Jerry M.

    2000-01-01

    An apparatus and method for defect and failure-mechanism testing of integrated circuits (ICs) is disclosed. The apparatus provides an operating voltage, V.sub.DD, to an IC under test and measures a transient voltage component, V.sub.DDT, signal that is produced in response to switching transients that occur as test vectors are provided as inputs to the IC. The amplitude or time delay of the V.sub.DDT signal can be used to distinguish between defective and defect-free (i.e. known good) ICs. The V.sub.DDT signal is measured with a transient digitizer, a digital oscilloscope, or with an IC tester that is also used to input the test vectors to the IC. The present invention has applications for IC process development, for the testing of ICs during manufacture, and for qualifying ICs for reliability.

  3. Standard test method for measurement of fatigue crack growth rates

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2015-01-01

    1.1 This test method covers the determination of fatigue crack growth rates from near-threshold to Kmax controlled instability. Results are expressed in terms of the crack-tip stress-intensity factor range (ΔK), defined by the theory of linear elasticity. 1.2 Several different test procedures are provided, the optimum test procedure being primarily dependent on the magnitude of the fatigue crack growth rate to be measured. 1.3 Materials that can be tested by this test method are not limited by thickness or by strength so long as specimens are of sufficient thickness to preclude buckling and of sufficient planar size to remain predominantly elastic during testing. 1.4 A range of specimen sizes with proportional planar dimensions is provided, but size is variable to be adjusted for yield strength and applied force. Specimen thickness may be varied independent of planar size. 1.5 The details of the various specimens and test configurations are shown in Annex A1-Annex A3. Specimen configurations other than t...

  4. A novel method for feasibility testing urban sustainable development policies

    Directory of Open Access Journals (Sweden)

    O’Doherty Travis

    2013-01-01

    Full Text Available Policy making to promote more sustainable development is a complex task due in part to the large number of both stakeholders and potential policies. Policy feasibility testing provides a guide to the viability and practicality of policy implementation and forms an important part of an evidence based policy making process. An extensive literature review has identified no standardized approach to feasibility testing. This paper addresses this knowledge gap by describing a novel method using Multi-Criteria Decision Analysis (MCDA for feasibility testing of policies aimed at increasing the sustainability of towns and villages in Ireland. Feasibility results are provided for 40 frequently cited policy interventions tested for 18 settlements in Ireland. Policies were selected in the arenas of transport, food, housing and urban form, energy, waste and water. Policies are feasibility tested through analysis of operational evidence from both quantitative and qualitative data sources. Following testing, policies are ranked in terms of feasibility. This research examines the effectiveness of local and national level policies and the importance of both local community involvement and central government regulation in policy success. The inter-settlement variation in feasibility testing scores prioritises policy selection and aims to reduce cherry-picking of policies to support the viewpoints of the decision maker. Although developed for an Irish urban context the methods described here may have applicability elsewhere.

  5. A method for evaluating horizontal well pumping tests.

    Science.gov (United States)

    Langseth, David E; Smyth, Andrew H; May, James

    2004-01-01

    Predicting the future performance of horizontal wells under varying pumping conditions requires estimates of basic aquifer parameters, notably transmissivity and storativity. For vertical wells, there are well-established methods for estimating these parameters, typically based on either the recovery from induced head changes in a well or from the head response in observation wells to pumping in a test well. Comparable aquifer parameter estimation methods for horizontal wells have not been presented in the ground water literature. Formation parameter estimation methods based on measurements of pressure in horizontal wells have been presented in the petroleum industry literature, but these methods have limited applicability for ground water evaluation and are based on pressure measurements in only the horizontal well borehole, rather than in observation wells. This paper presents a simple and versatile method by which pumping test procedures developed for vertical wells can be applied to horizontal well pumping tests. The method presented here uses the principle of superposition to represent the horizontal well as a series of partially penetrating vertical wells. This concept is used to estimate a distance from an observation well at which a vertical well that has the same total pumping rate as the horizontal well will produce the same drawdown as the horizontal well. This equivalent distance may then be associated with an observation well for use in pumping test algorithms and type curves developed for vertical wells. The method is shown to produce good results for confined aquifers and unconfined aquifers in the absence of delayed yield response. For unconfined aquifers, the presence of delayed yield response increases the method error.

  6. Validation and Verification (V and V) Testing on Midscale Flame Resistant (FR) Test Method

    Science.gov (United States)

    2016-12-16

    materials . The results demonstrated that the Midscale test is a quick and cost-effective method for evaluation of FR performance of design features...standard and novel FR materials and design configurations during fire engulfment. Details of the test method and its development can be found in the...employed in the FRACU is a ripstop fabric blend of 65% FR rayon, 25% para- aramid and 10% nylon. The iCVC material is Nylon/Cotton/Nomex. All three

  7. Natural tracer test simulation by stochastic particle tracking method

    International Nuclear Information System (INIS)

    Ackerer, P.; Mose, R.; Semra, K.

    1990-01-01

    Stochastic particle tracking methods are well adapted to 3D transport simulations where discretization requirements of other methods usually cannot be satisfied. They do need a very accurate approximation of the velocity field. The described code is based on the mixed hybrid finite element method (MHFEM) to calculated the piezometric and velocity field. The random-walk method is used to simulate mass transport. The main advantages of the MHFEM over FD or FE are the simultaneous calculation of pressure and velocity, which are considered as unknowns; the possibility of interpolating velocities everywhere; and the continuity of the normal component of the velocity vector from one element to another. For these reasons, the MHFEM is well adapted for particle tracking methods. After a general description of the numerical methods, the model is used to simulate the observations made during the Twin Lake Tracer Test in 1983. A good match is found between observed and simulated heads and concentrations. (Author) (12 refs., 4 figs.)

  8. Linear shrinkage test: justification for its reintroduction as a standard South African test method

    CSIR Research Space (South Africa)

    Sampson, LR

    2009-06-04

    Full Text Available Several problems with the linear shrinkage test specified in Method A4 of the THM 1 1979 were addressed as part of this investigation in an effort to improve the alleged poor reproducibility of the test and justify its reintroduction into THM 1. A...

  9. The new null testing method for the special optical window

    Science.gov (United States)

    Huang, Changchun

    2009-07-01

    The high speed, high precision and wide range specifications are requirement for the modern aircraft, which the traditional hemispherical dome can't achieve now, and the novel conformal window instead can enhance the aerodynamic performance of the aircraft obviously. To reduce the aerodynamic drag and radar cross-section, the window geometry is generally aspheric in shape. As a result, the involved fabrication and testing processes are much more challenging than that of conventional optics and must be mastered before these windows and systems can be implemented at an acceptable cost and risk. Metrology is one of the critical areas required to advance the conformal window technology. But as the surface of these conformal windows is not the traditional sphere lens, the measurement method for it is infeasible with the conventional optics measurement processes. This paper we express the development of testing technology for the special conformal windows in brief, and emphatically introduces one available novel testing method- a new null testing, and here based on the theory of compensation methods, The principle of Offner's refractive null lens has been extended to test the transmission wavefront through conformal window optics and provide feedback during surface fabrication. a compensator system for the was designed for the conformal window is given which parameters are 100mm for its aperture and two parabolic surface as conformal window, the final residual wavefront error(RMS) of which is less than 1/20λ(λ=632.8nm).

  10. Field Testing of Compartmentalization Methods for Multifamily Construction

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Westford, MA (United States); Lstiburek, J. [Building Science Corporation, Westford, MA (United States)

    2015-03-01

    The 2012 IECC has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure for both single-family and multifamily construction in Climate Zones 3-8. Other programs (LEED, ASHRAE 189, ASHRAE 62.2) have similar or tighter compartmentalization requirements, driving the need for easier and more effective methods of compartmentalization in multifamily buildings. Builders and practitioners have found that fire-resistance rated wall assemblies are a major source of difficulty in air sealing/compartmentalization, particularly in townhouse construction. This problem is exacerbated when garages are “tucked in” to the units and living space is located over the garages. In this project, Building Science Corporation examined the taping of exterior sheathing details to improve air sealing results in townhouse and multifamily construction, when coupled with a better understanding of air leakage pathways. Current approaches are cumbersome, expensive, time consuming, and ineffective; these details were proposed as a more effective and efficient method. The effectiveness of these air sealing methods was tested with blower door testing, including “nulled” or “guarded” testing (adjacent units run at equal test pressure to null out inter-unit air leakage, or “pressure neutralization”). Pressure diagnostics were used to evaluate unit-to-unit connections and series leakage pathways (i.e., air leakage from exterior, into the fire-resistance rated wall assembly, and to the interior).

  11. [Study of the influence of uniform transverse magnetic field on the dose distribution of high energy electron beam using Monte Carlo method].

    Science.gov (United States)

    You, Shihu; Xu, Yun; Wu, Zhangwen; Hou, Qing; Guo, Chengjun

    2014-12-01

    In the present work, Monte Carlo simulations were employed to study the characteristics of the dose distribution of high energy electron beam in the presence of uniform transverse magnetic field. The simulations carried out the transport processes of the 30 MeV electron beam in the homogeneous water phantom with different magnetic field. It was found that the dose distribution of the 30 MeV electron beam had changed significantly because of the magnetic field. The result showed that the range of the electron beam was decreased obviously and it formed a very high dose peak at the end of the range, and the ratio of maximum dose to the dose of the surface was greatly increased. The results of this study demonstrated that we could change the depth dose distribution of electron beam which is analogous to the heavy ion by modulating the energy of the electron and magnetic field. It means that using magnetic fields in conjunction with electron radiation therapy has great application prospect, but it also has brought new challenges for the research of dose algorithm.

  12. Fractional corresponding operator in quantum mechanics and applications: A uniform fractional Schrödinger equation in form and fractional quantization methods

    International Nuclear Information System (INIS)

    Zhang, Xiao; Wei, Chaozhen; Liu, Yingming; Luo, Maokang

    2014-01-01

    In this paper we use Dirac function to construct a fractional operator called fractional corresponding operator, which is the general form of momentum corresponding operator. Then we give a judging theorem for this operator and with this judging theorem we prove that R–L, G–L, Caputo, Riesz fractional derivative operator and fractional derivative operator based on generalized functions, which are the most popular ones, coincide with the fractional corresponding operator. As a typical application, we use the fractional corresponding operator to construct a new fractional quantization scheme and then derive a uniform fractional Schrödinger equation in form. Additionally, we find that the five forms of fractional Schrödinger equation belong to the particular cases. As another main result of this paper, we use fractional corresponding operator to generalize fractional quantization scheme by using Lévy path integral and use it to derive the corresponding general form of fractional Schrödinger equation, which consequently proves that these two quantization schemes are equivalent. Meanwhile, relations between the theory in fractional quantum mechanics and that in classic quantum mechanics are also discussed. As a physical example, we consider a particle in an infinite potential well. We give its wave functions and energy spectrums in two ways and find that both results are the same

  13. Considerations and Methods for Usability Testing with Children

    DEFF Research Database (Denmark)

    Andersen, Malene Hjortboe; Khalid, Md. Saifuddin; Brooks, Eva Irene

    2017-01-01

    of these methods is that they are designed for adults and are not necessarily appropriate to investigations including children. The guiding questions for this systematic literature review are (1) the motivation for conducting usability tests with children, and (2) the kind of methodological, practical, and ethical...

  14. The added value of proficiency tests: choosing the proper method

    NARCIS (Netherlands)

    Nijs, den A.P.M.; Berg, van den W.

    2013-01-01

    To gain insight into the different extraction processes used in laboratories in various European countries and the effect these methods might have on the number of Meloidogyne second-stage juveniles (J2) extracted from soil samples, a ring test with 2 elements was conducted. The first element used

  15. 16 CFR 1509.6 - Component-spacing test method.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Component-spacing test method. 1509.6 Section 1509.6 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT... applied to the wedge perpendicular to the plane of the crib side. ...

  16. Heart rate-based lactate minimum test: a reproducible method.

    NARCIS (Netherlands)

    Strupler, M.; Muller, G.; Perret, C.

    2009-01-01

    OBJECTIVE: To find the individual intensity for aerobic endurance training, the lactate minimum test (LMT) seems to be a promising method. LMTs described in the literature consist of speed or work rate-based protocols, but for training prescription in daily practice mostly heart rate is used. The

  17. Field test of a new Australian method of rangeland monitoring

    Science.gov (United States)

    Suzanne Mayne; Neil West

    2001-01-01

    Managers need more efficient means of monitoring changes on the lands they manage. Accordingly, a new Australian approach was field tested and compared to the Daubenmire method of assessing plant cover, litter, and bare soil. The study area was a 2 mile wide by 30.15 mile long strip, mostly covered by salt desert shrub ecosystem types, centered along the SE boundary of...

  18. Comparative study of heuristic evaluation and usability testing methods.

    Science.gov (United States)

    Thyvalikakath, Thankam Paul; Monaco, Valerie; Thambuganipalle, Himabindu; Schleyer, Titus

    2009-01-01

    Usability methods, such as heuristic evaluation, cognitive walk-throughs and user testing, are increasingly used to evaluate and improve the design of clinical software applications. There is still some uncertainty, however, as to how those methods can be used to support the development process and evaluation in the most meaningful manner. In this study, we compared the results of a heuristic evaluation with those of formal user tests in order to determine which usability problems were detected by both methods. We conducted heuristic evaluation and usability testing on four major commercial dental computer-based patient records (CPRs), which together cover 80% of the market for chairside computer systems among general dentists. Both methods yielded strong evidence that the dental CPRs have significant usability problems. An average of 50% of empirically-determined usability problems were identified by the preceding heuristic evaluation. Some statements of heuristic violations were specific enough to precisely identify the actual usability problem that study participants encountered. Other violations were less specific, but still manifested themselves in usability problems and poor task outcomes. In this study, heuristic evaluation identified a significant portion of problems found during usability testing. While we make no assumptions about the generalizability of the results to other domains and software systems, heuristic evaluation may, under certain circumstances, be a useful tool to determine design problems early in the development cycle.

  19. Test method for measuring insulation values of cryogenic pipes

    NARCIS (Netherlands)

    Velthuis, J.F.M.; Blokland, H.; Klaver, B.W.; Beld, C. van de

    2010-01-01

    In this paper a large-area heat flux and temperature sensor (HFT) is used for the evaluation of the insulation value of cryogenic pipes. The HFT is flexible and clamp-on. The test method is relatively simple and can be used in-situ. The HFT makes it possible to monitor insulation performance over

  20. Harmonisation of microbial sampling and testing methods for distillate fuels

    Energy Technology Data Exchange (ETDEWEB)

    Hill, G.C.; Hill, E.C. [ECHA Microbiology Ltd., Cardiff (United Kingdom)

    1995-05-01

    Increased incidence of microbial infection in distillate fuels has led to a demand for organisations such as the Institute of Petroleum to propose standards for microbiological quality, based on numbers of viable microbial colony forming units. Variations in quality requirements, and in the spoilage significance of contaminating microbes plus a tendency for temporal and spatial changes in the distribution of microbes, makes such standards difficult to implement. The problem is compounded by a diversity in the procedures employed for sampling and testing for microbial contamination and in the interpretation of the data obtained. The following paper reviews these problems and describes the efforts of The Institute of Petroleum Microbiology Fuels Group to address these issues and in particular to bring about harmonisation of sampling and testing methods. The benefits and drawbacks of available test methods, both laboratory based and on-site, are discussed.

  1. Radioactive waste isolation in salt: Peer review of the Office of Nuclear Waste Isolation's draft report on a multifactor test design to investigate uniform corrosion of low-carbon steel

    Energy Technology Data Exchange (ETDEWEB)

    Paddock, R.A.; Lerman, A.; Ditmars, J.D.; Macdonald, D.D.; Peerenboom, J.P.; Was, G.S.; Harrison, W.

    1987-01-01

    This report documents Argonne National Laboratory's review of an internal technical memorandum prepared by Battelle Memorial Institute's Office of Nuclear Waste Isolation (ONWI) entitled Multifactor Test Design to Investigate Uniform Corrosion of Low-Carbon Steel in a Nuclear Waste Salt Repository Environment. The several major areas of concern identified by peer review panelists are important to the credibility of the test design proposed in the memorandum and are to adequately addressed there. These areas of concern, along with specific recommendations to improve their treatment, are discussed in detail in Sec. 2 of this report. The twenty recommendations, which were abstracted from those discussions, are presented essentially in the order in which they are introduced in Sec. 2.

  2. Radioactive waste isolation in salt: Peer review of the Office of Nuclear Waste Isolation's draft report on a multifactor test design to investigate uniform corrosion of low-carbon steel

    International Nuclear Information System (INIS)

    Paddock, R.A.; Lerman, A.; Ditmars, J.D.; Macdonald, D.D.; Peerenboom, J.P.; Was, G.S.; Harrison, W.

    1987-01-01

    This report documents Argonne National Laboratory's review of an internal technical memorandum prepared by Battelle Memorial Institute's Office of Nuclear Waste Isolation (ONWI) entitled Multifactor Test Design to Investigate Uniform Corrosion of Low-Carbon Steel in a Nuclear Waste Salt Repository Environment. The several major areas of concern identified by peer review panelists are important to the credibility of the test design proposed in the memorandum and are to adequately addressed there. These areas of concern, along with specific recommendations to improve their treatment, are discussed in detail in Sec. 2 of this report. The twenty recommendations, which were abstracted from those discussions, are presented essentially in the order in which they are introduced in Sec. 2

  3. Rheological Method for Alpha Test Evaluation of Developing Superplasticizers’ Performance: Channel Flow Test

    Directory of Open Access Journals (Sweden)

    Jae Hong Kim

    2017-01-01

    Full Text Available Advance in high-range water-reducing admixture revolutionizes the workability and constructability of conventional vibrated concrete as well as self-consolidating concrete. Its need from construction fields has increased, and consequently a variety of new-type polycarboxylates, base polymers for the admixture, are being formulated in these days. Synthesizing new polymers needs a quick, but reliable, test to evaluate its performance on concrete. The test is also asked for selecting the best applicable brand of them before a test concrete will be mixed. This paper proposes a “channel flow test” and its usage for the purpose. The proposed procedure for the test includes the mix proportion of a test mortar, the test method, and rheological interpretation of the test results.

  4. Standard Test Methods for Wet Insulation Integrity Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 These test methods provide procedures to determine the insulation resistance of a photovoltaic (PV) module, i.e. the electrical resistance between the module's internal electrical components and its exposed, electrically conductive, non-current carrying parts and surfaces. 1.2 The insulation integrity procedures are a combination of wet insulation resistance and wet dielectric voltage withstand test procedures. 1.3 These procedures are similar to and reference the insulation integrity test procedures described in Test Methods E 1462, with the difference being that the photovoltaic module under test is immersed in a wetting solution during the procedures. 1.4 These test methods do not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of these test methods. 1.5 The values stated in SI units are to be regarded as the standard. 1.6 There is no similar or equivalent ISO standard. 1.7 This standard does not purport to address all of the safety conce...

  5. High sensitive quench detection method using an integrated test wire

    International Nuclear Information System (INIS)

    Fevrier, A.; Tavergnier, J.P.; Nithart, H.; Kiblaire, M.; Duchateau, J.L.

    1981-01-01

    A high sensitive quench detection method which works even in the presence of an external perturbing magnetic field is reported. The quench signal is obtained from the difference in voltages at the superconducting winding terminals and at the terminals at a secondary winding strongly coupled to the primary. The secondary winding could consist of a ''zero-current strand'' of the superconducting cable not connected to one of the winding terminals or an integrated normal test wire inside the superconducting cable. Experimental results on quench detection obtained by this method are described. It is shown that the integrated test wire method leads to efficient and sensitive quench detection, especially in the presence of an external perturbing magnetic field

  6. Liouville theory and uniformization of four-punctured sphere

    OpenAIRE

    Hadasz, Leszek; Jaskolski, Zbigniew

    2006-01-01

    Few years ago Zamolodchikov and Zamolodchikov proposed an expression for the 4-point classical Liouville action in terms of the 3-point actions and the classical conformal block. In this paper we develop a method of calculating the uniformizing map and the uniformizing group from the classical Liouville action on n-punctured sphere and discuss the consequences of Zamolodchikovs conjecture for an explicit construction of the uniformizing map and the uniformizing group for the sphere with four ...

  7. Standard test method for tension testing of structural alloys in liquid helium

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method describes procedures for the tension testing of structural alloys in liquid helium. The format is similar to that of other ASTM tension test standards, but the contents include modifications for cryogenic testing which requires special apparatus, smaller specimens, and concern for serrated yielding, adiabatic heating, and strain-rate effects. 1.2 To conduct a tension test by this standard, the specimen in a cryostat is fully submerged in normal liquid helium (He I) and tested using crosshead displacement control at a nominal strain rate of 10−3 s−1 or less. Tests using force control or high strain rates are not considered. 1.3 This standard specifies methods for the measurement of yield strength, tensile strength, elongation, and reduction of area. The determination of the elastic modulus is treated in Test Method E 111. Note 1—The boiling point of normal liquid helium (He I) at sea level is 4.2 K (−269°C or −452.1°F or 7.6°R). It decreases with geographic elevation and is...

  8. Falsification Testing of Instrumental Variables Methods for Comparative Effectiveness Research.

    Science.gov (United States)

    Pizer, Steven D

    2016-04-01

    To demonstrate how falsification tests can be used to evaluate instrumental variables methods applicable to a wide variety of comparative effectiveness research questions. Brief conceptual review of instrumental variables and falsification testing principles and techniques accompanied by an empirical application. Sample STATA code related to the empirical application is provided in the Appendix. Comparative long-term risks of sulfonylureas and thiazolidinediones for management of type 2 diabetes. Outcomes include mortality and hospitalization for an ambulatory care-sensitive condition. Prescribing pattern variations are used as instrumental variables. Falsification testing is an easily computed and powerful way to evaluate the validity of the key assumption underlying instrumental variables analysis. If falsification tests are used, instrumental variables techniques can help answer a multitude of important clinical questions. © Health Research and Educational Trust.

  9. OCL-BASED TEST CASE GENERATION USING CATEGORY PARTITIONING METHOD

    Directory of Open Access Journals (Sweden)

    A. Jalila

    2015-10-01

    Full Text Available The adoption of fault detection techniques during initial stages of software development life cycle urges to improve reliability of a software product. Specification-based testing is one of the major criterions to detect faults in the requirement specification or design of a software system. However, due to the non-availability of implementation details, test case generation from formal specifications become a challenging task. As a novel approach, the proposed work presents a methodology to generate test cases from OCL (Object constraint Language formal specification using Category Partitioning Method (CPM. The experiment results indicate that the proposed methodology is more effective in revealing specification based faults. Furthermore, it has been observed that OCL and CPM form an excellent combination for performing functional testing at the earliest to improve software quality with reduced cost.

  10. Standard test method for laboratory evaluation of magnesium sacrificial anode test specimens for underground applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure that measures the two fundamental performance properties of magnesium sacrificial anode test specimens operating in a saturated calcium sulfate, saturated magnesium hydroxide environment. The two fundamental properties are electrode (oxidation potential) and ampere hours (Ah) obtained per unit mass of specimen consumed. Magnesium anodes installed underground are usually surrounded by a backfill material that typically consists of 75 % gypsum (CaSO4·2H2O), 20 % bentonite clay, and 5 % sodium sulfate (Na2SO4). The calcium sulfate, magnesium hydroxide test electrolyte simulates the long term environment around an anode installed in the gypsum-bentonite-sodium sulfate backfill. 1.2 This test method is intended to be used for quality assurance by anode manufacturers or anode users. However, long term field performance properties may not be identical to property measurements obtained using this laboratory test. Note 1—Refer to Terminology G 15 for terms used ...

  11. Should School Nurses Wear Uniforms?

    Science.gov (United States)

    Journal of School Health, 2001

    2001-01-01

    This 1958 paper questions whether school nurses should wear uniforms (specifically, white uniforms). It concludes that white uniforms are often associated with the treatment of ill people, and since many people have a fear reaction to them, they are not necessary and are even undesirable. Since school nurses are school staff members, they should…

  12. Nondestructive testing method for a new generation of electronics

    Directory of Open Access Journals (Sweden)

    Azin Anton

    2018-01-01

    Full Text Available The implementation of the Smart City system needs reliable and smoothly operating electronic equipment. The study is aimed at developing a nondestructive testing method for electronic equipment and its components. This method can be used to identify critical design defects of printed circuit boards (PCB and to predict their service life, taking into account the nature of probable operating loads. The study uses an acoustic emission method to identify and localize critical design defects of printed circuit boards. Geometric dimensions of detected critical defects can be determined by the X-ray tomography method. Based on the results of the study, a method combining acoustic emission and X-ray tomography was developed for nondestructive testing of printed circuit boards. The stress-strain state of solder joints containing detected defects was analyzed. This paper gives an example of using the developed method for estimating the degree of damage to joints between PCB components and predicting the service life of the entire PCB.

  13. Seismic test qualification of electrical equipment - testing methods in use to EDF

    International Nuclear Information System (INIS)

    Fabries, R.

    1981-01-01

    At the beginning, for the 900 MW Power Plant level, the testing method in application used the single axis test by sine beat of 10 cycles according to the specifications of the guide IEEE 344-71. When the french guide UTEC 20-420 came into force we have had to define another testing method (EDF standard: HN20 E52) which utilize the single-axis test either by a sine beat of 5-cycles or by a synthetized time history. We present here the mains criterions allowing to justify: -The single-axis test. The single frequency wave (when the Initial Response Spectrum (IRS) present a narrow band). The use of one sine beat of 5-cycles or one synthetized time history. The need of taking into account the high stress level. This oligocyclic stress fatigue explains why one beat of 5-cycles may be as severe as one time history of 20 seconds (with the same level of strong response spectrum). Then, we conclude that the durating of the testing wave applied to the equipment shall be considered as a relative parameter only. The weight of the SSE tests by respect to the OBE tests. The precautions to take in order to: generate and check accurately the synthetized time history, choice the test frequencies when the sine beat is used. (orig./HP)

  14. Small punch test evaluation methods for material characterisation

    Energy Technology Data Exchange (ETDEWEB)

    Janča, Adam, E-mail: adam.janca@fjfi.cvut.cz; Siegl, Jan, E-mail: jan.siegl@fjfi.cvut.cz; Haušild, Petr, E-mail: petr.hausild@fjfi.cvut.cz

    2016-12-01

    The Small Punch Test (SPT) is one of the most widespread mechanical testing methods using miniaturized specimens. The paper presented deals with the time independent SPT, in which a flat specimen is bent by means of a (hemi)spherical punch moving at a constant velocity. The main goal is to relate the measured data to deformation processes taking place during specimen loading. Understanding of such relations is crucial for characterizing a material using any non-standardized experimental procedure. Using enhanced instrumentation, not only traditional load-displacement or load-deflection curves could be obtained, but also specimen thinning could be continuously measured and evaluated. Five alloys having a broad range of mechanical properties were tested. The results obtained were evaluated using both traditional and newly proposed methods and they were correlated with results of the conventional tensile test. The methods proposed seem to lead to a universal correlation between SPT results and tensile characteristics. - Highlights: • The newly proposed methodology significantly improved results of SPT. • Plastic deformation starts inside the specimen from the very beginning of loading. • Specimen thinning = punch displacement−specimen deflection. • Material response to loading is well illustrated by the novel load-thinning curve.

  15. Hydrocoin level 3 - Testing methods for sensitivity/uncertainty analysis

    International Nuclear Information System (INIS)

    Grundfelt, B.; Lindbom, B.; Larsson, A.; Andersson, K.

    1991-01-01

    The HYDROCOIN study is an international cooperative project for testing groundwater hydrology modelling strategies for performance assessment of nuclear waste disposal. The study was initiated in 1984 by the Swedish Nuclear Power Inspectorate and the technical work was finalised in 1987. The participating organisations are regulatory authorities as well as implementing organisations in 10 countries. The study has been performed at three levels aimed at studying computer code verification, model validation and sensitivity/uncertainty analysis respectively. The results from the first two levels, code verification and model validation, have been published in reports in 1988 and 1990 respectively. This paper focuses on some aspects of the results from Level 3, sensitivity/uncertainty analysis, for which a final report is planned to be published during 1990. For Level 3, seven test cases were defined. Some of these aimed at exploring the uncertainty associated with the modelling results by simply varying parameter values and conceptual assumptions. In other test cases statistical sampling methods were applied. One of the test cases dealt with particle tracking and the uncertainty introduced by this type of post processing. The amount of results available is substantial although unevenly spread over the test cases. It has not been possible to cover all aspects of the results in this paper. Instead, the different methods applied will be illustrated by some typical analyses. 4 figs., 9 refs

  16. Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.

    Science.gov (United States)

    Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval

    2016-09-01

    The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.

  17. Optimisation of test and maintenance based on probabilistic methods

    International Nuclear Information System (INIS)

    Cepin, M.

    2001-01-01

    This paper presents a method, which based on models and results of probabilistic safety assessment, minimises the nuclear power plant risk by optimisation of arrangement of safety equipment outages. The test and maintenance activities of the safety equipment are timely arranged, so the classical static fault tree models are extended with the time requirements to be capable to model real plant states. A house event matrix is used, which enables modelling of the equipment arrangements through the discrete points of time. The result of the method is determination of such configuration of equipment outages, which result in the minimal risk. Minimal risk is represented by system unavailability. (authors)

  18. Conventional cable testing methods: strengths, weaknesses and possibilities

    International Nuclear Information System (INIS)

    Reynolds, P.H.

    1988-01-01

    The paper reviews the major conventional methods that can be used to test power plant cables. It assesses their usefulness in diagnosing the condition of the insulation of the cable and then proposes some possible directions for innovation. The methods examined are dc insulation resistance measurement, ac signal injection for continuous monitoring and fault location, and the ac measurement of capacitance and loss angle. Specific subjects considered are the effects of temperature, cable construction and installation, and the validity of insulation resistance or loss angle measurement. The innovative proposals refer to the use of automation in the measurement and of computer-based Expert Systems for the evaluation of the results

  19. Test Method for Rheological Behavior of Mortar for Building Work

    Directory of Open Access Journals (Sweden)

    Korobko Bogdan

    2017-09-01

    Full Text Available This paper offers a test method for rheological behavior of mortars with different mobility and different composition, which are used for execution of construction work. This method is based on investigation of the interaction between the valve ball and the mortar under study and allows quick defining of experimental variables for any composition of building mortars. Certain rheological behavior will permit to calculate the design parameters of machines for specific conditions of work performance – mixing (pre-operation, pressure generation, pumping to the work site, workpiece surfacing.

  20. Method for studying the plastic buckling of shells. Testing

    International Nuclear Information System (INIS)

    Alix, M.; Combescure, A.; Hoffmann, A.; Roche, R.

    1980-05-01

    In this article a description is given of the method selected for studying the elasto-plastic buckling of shells of any shape. The emphasis is mainly on three points: the difficulty in making a strict formulation with respect to plasticity, the model selected (MOTAN model) is presented; the effect of so called 'non conservative' forces; and the effect of great deformations that might precede the buckling. The method is compared to tests: basket handle buckling of bottoms, buckling of elliptical bottoms under internal pressure, of compresses thin tubes, of metal drums, spherical diaphragm, shearing rings [fr

  1. The Use of OXYGEN-18 in the Development of Methods for Controlled Sputter Deposition of High Critical Transition Temperature Material Thin Films of Predicted Composition and Good Uniformity

    Science.gov (United States)

    Tidrow, Steven Clay

    Two primary concerns, in the sputter deposition of high T_{c} material films, are the prevention of oxygen deficiency in the films and the elimination of the negative ion effect. "Oxygen deficiency" occurs when the amount of oxygen incorporated into the film is less than the amount of oxygen required to form the superconducting material lattice. Oxygen deficiency is due to the volatile nature of oxygen. The negative ion effect occurs when an atom or molecule (typically oxygen) gains an extra electron, is accelerated away from the target and impinges upon a film being grown directly in front of the sputtering target. The impinging particle has enough energy to cause resputtering of the deposited film. The presence of Sr and to a greater extent Ba, may enhance the negative ion effect in these materials. However, it is oxygen which readily forms negative ions that is primarily responsible for the negative ion effect. Thus, oxygen must be given special attention in the sputter deposition of high T_{c} material films. A specially designed sputtering system is used to demonstrate that the negative ion effect can be reduced such that large uniform high T_{c} material films possessing predicted and repeated composition can be grown in an on-axis arrangement. Utilizing this same sputtering system and the volatile nature of oxygen, it is demonstrated that oxygen processes occurring in the chamber during growth of high T_ {c} material films can be investigated using the tracer ^{18}O. In particular, it is shown that ^{18}O can be utilized as a tool for (1) investigating the negative ion effect, (2) investigating oxygen incorporation into high T_{c} material films, (3) investigating oxygen incorporation into the target, (4) tailoring films for oxygen migration and interface investigations and (5) tailoring films for the other specific oxygen investigations. Such sputtering systems that utilize the tracer ^{18}O are necessary for systematic growth of high T_ {c} material films

  2. Standard Test Method for Wet Insulation Integrity Testing of Photovoltaic Arrays

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This test method covers a procedure to determine the insulation resistance of a photovoltaic (PV) array (or its component strings), that is, the electrical resistance between the array's internal electrical components and is exposed, electrically conductive, non-current carrying parts and surfaces of the array. 1.2 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  3. An improved brine shrimp larvae lethality microwell test method.

    Science.gov (United States)

    Zhang, Yi; Mu, Jun; Han, Jinyuan; Gu, Xiaojie

    2012-01-01

    This article described an improved brine shrimp larvae lethality microwell test method. A simply designed connecting vessel with alternative photoperiod was used to culture and collect high yield of active Artemia parthenogenetica nauplii for brine shrimp larvae lethality microwell test. Using this method, pure A. parthenogenetica nauplii suspension was easily cultured and harvested with high density about 100-150 larvae per milliliter and the natural mortality was reduced to near zero by elimination of unnecessary artificial disturbance. And its sensitivity was validated by determination of LC(50)-24 h of different reference toxicants including five antitumor agents, two pesticides, three organic pollutants, and four heavy metals salts, most of which exhibited LC(50)-24 h between 0.07 and 58.43 mg/L except for bleomycin and mitomycin C with LC(50)-24 h over 300 mg/L.

  4. Standard test methods for characterizing duplex grain sizes

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 These test methods provide simple guidelines for deciding whether a duplex grain size exists. The test methods separate duplex grain sizes into one of two distinct classes, then into specific types within those classes, and provide systems for grain size characterization of each type. 1.2 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns associated with its use. It is the responsibility of the user of this standard to consult appropriate safety and health practices and determine the applicability of regulatory limitations prior to its use.

  5. State of the art in non-animal approaches for skin sensitization testing: from individual test methods towards testing strategies.

    Science.gov (United States)

    Ezendam, Janine; Braakhuis, Hedwig M; Vandebriel, Rob J

    2016-12-01

    The hazard assessment of skin sensitizers relies mainly on animal testing, but much progress is made in the development, validation and regulatory acceptance and implementation of non-animal predictive approaches. In this review, we provide an update on the available computational tools and animal-free test methods for the prediction of skin sensitization hazard. These individual test methods address mostly one mechanistic step of the process of skin sensitization induction. The adverse outcome pathway (AOP) for skin sensitization describes the key events (KEs) that lead to skin sensitization. In our review, we have clustered the available test methods according to the KE they inform: the molecular initiating event (MIE/KE1)-protein binding, KE2-keratinocyte activation, KE3-dendritic cell activation and KE4-T cell activation and proliferation. In recent years, most progress has been made in the development and validation of in vitro assays that address KE2 and KE3. No standardized in vitro assays for T cell activation are available; thus, KE4 cannot be measured in vitro. Three non-animal test methods, addressing either the MIE, KE2 or KE3, are accepted as OECD test guidelines, and this has accelerated the development of integrated or defined approaches for testing and assessment (e.g. testing strategies). The majority of these approaches are mechanism-based, since they combine results from multiple test methods and/or computational tools that address different KEs of the AOP to estimate skin sensitization potential and sometimes potency. Other approaches are based on statistical tools. Until now, eleven different testing strategies have been published, the majority using the same individual information sources. Our review shows that some of the defined approaches to testing and assessment are able to accurately predict skin sensitization hazard, sometimes even more accurate than the currently used animal test. A few defined approaches are developed to provide an

  6. Performing Allen's test in immobile hand: The Esmarch bandage method

    Directory of Open Access Journals (Sweden)

    Nebil Yesiloglu

    2015-12-01

    Full Text Available In this study, an alternative method of assessing hand vascular flow using a modification of Allen's test is presented. This technique may be helpful for patients who have immobile hands due to severe trauma, patients scheduled for free tissue transfer reconstruction, patients under general anesthesia in intensive care units that require serial arterial blood gas analyses, and emergency coronary by-pass candidates who decided to receive radial arterial grafts. [Hand Microsurg 2015; 4(3.000: 83-85

  7. The virtual fields method applied to spalling tests on concrete

    Directory of Open Access Journals (Sweden)

    Forquin P.

    2012-08-01

    Full Text Available For one decade spalling techniques based on the use of a metallic Hopkinson bar put in contact with a concrete sample have been widely employed to characterize the dynamic tensile strength of concrete at strain-rates ranging from a few tens to two hundreds of s−1. However, the processing method mainly based on the use of the velocity profile measured on the rear free surface of the sample (Novikov formula remains quite basic and an identification of the whole softening behaviour of the concrete is out of reach. In the present paper a new processing method is proposed based on the use of the Virtual Fields Method (VFM. First, a digital high speed camera is used to record the pictures of a grid glued on the specimen. Next, full-field measurements are used to obtain the axial displacement field at the surface of the specimen. Finally, a specific virtual field has been defined in the VFM equation to use the acceleration map as an alternative ‘load cell’. This method applied to three spalling tests allowed to identify Young’s modulus during the test. It was shown that this modulus is constant during the initial compressive part of the test and decreases in the tensile part when micro-damage exists. It was also shown that in such a simple inertial test, it was possible to reconstruct average axial stress profiles using only the acceleration data. Then, it was possible to construct local stress-strain curves and derive a tensile strength value.

  8. Accountancy, teaching methods, sex, and American College Test scores.

    Science.gov (United States)

    Heritage, J; Harper, B S; Harper, J P

    1990-10-01

    This study examines the significance of sex, methodology, academic preparation, and age as related to development of judgmental and problem-solving skills. Sex, American College Test (ACT) Mathematics scores, Composite ACT scores, grades in course work, grade point average (GPA), and age were used in studying the effects of teaching method on 96 students' ability to analyze data in financial statements. Results reflect positively on accounting students compared to the general college population and the women students in particular.

  9. Platelet function testing: methods of assessment and clinical utility.

    LENUS (Irish Health Repository)

    Mylotte, Darren

    2012-02-01

    Platelets play a central role in the regulation of both thrombosis and haemostasis yet tests of platelet function have, until recently, been exclusively used in the diagnosis and management of bleeding disorders. Recent advances have demonstrated the clinical utility of platelet function testing in patients with cardiovascular disease. The ex vivo measurement of response to antiplatelet therapies (aspirin and clopidogrel), by an ever-increasing array of platelet function tests, is with some assays, predictive of adverse clinical events and thus, represents an emerging area of interest for both the clinician and basic scientist. This review article will describe the advantages and disadvantages of the currently available methods of measuring platelet function and discuss both the limitations and emerging data supporting the role of platelet function studies in clinical practice.

  10. Platelet function testing: methods of assessment and clinical utility.

    LENUS (Irish Health Repository)

    Mylotte, Darren

    2011-01-01

    Platelets play a central role in the regulation of both thrombosis and haemostasis yet tests of platelet function have, until recently, been exclusively used in the diagnosis and management of bleeding disorders. Recent advances have demonstrated the clinical utility of platelet function testing in patients with cardiovascular disease. The ex vivo measurement of response to antiplatelet therapies (aspirin and clopidogrel), by an ever-increasing array of platelet function tests, is with some assays, predictive of adverse clinical events and thus, represents an emerging area of interest for both the clinician and basic scientist. This review article will describe the advantages and disadvantages of the currently available methods of measuring platelet function and discuss both the limitations and emerging data supporting the role of platelet function studies in clinical practice.

  11. New test and characterization methods for PV modules and cells

    Energy Technology Data Exchange (ETDEWEB)

    Van Aken, B.; Sommeling, P. [ECN Solar Energy, Petten (Netherlands); Scholten, H. [Solland, Heerlen (Netherlands); Muller, J. [Moser-Baer, Eindhoven (Netherlands); Grossiord, N. [Holst Centre, Eindhoven (Netherlands); Smits, C.; Blanco Mantecon, M. [Holland Innovative, Eindhoven (Netherlands); Verheijen, M.; Van Berkum, J. [Philips Innovation Services, Eindhoven (Netherlands)

    2012-08-15

    The results of the project geZONd (shared facility for solar module analysis and reliability testing) are described. The project was set up by Philips, ECN, Holst, Solland, OM and T and Holland Innovative. The partners have shared most of their testing and analysis equipment for PV modules and cells, and together developed new or improved methods (including the necessary application know-how). This enables faster and more efficient innovation projects for each partner, and via commercial exploitation for other interested parties. The project has concentrated on five failure modes: corrosion, delamination, moisture ingress, UV irradiation, and mechanical bending. Test samples represented all main PV technologies: wafer based PV and rigid and flexible thin-film PV. Breakthroughs are in very early detection of corrosion, in quantitative characterization of adhesion, in-situ detection of humidity and oxygen inside modules, and ultra-fast screening of materials on UV stability.

  12. Experimental method for testing diffraction properties of reflection waveguide holograms.

    Science.gov (United States)

    Xie, Yi; Kang, Ming-Wu; Wang, Bao-Ping

    2014-07-01

    Waveguide holograms' diffraction properties include peak wavelength and diffraction efficiency, which play an important role in determining their display performance. Based on the record and reconstruction theory of reflection waveguide holograms, a novel experimental method for testing diffraction properties is introduced and analyzed in this paper, which uses a plano-convex lens optically contacted to the surface of the substrate plate of the waveguide hologram, so that the diffracted light beam can be easily detected. Then an experiment is implemented. The designed reconstruction wavelength of the test sample is 530 nm, and its diffraction efficiency is 100%. The experimental results are a peak wavelength of 527.7 nm and a diffraction efficiency of 94.1%. It is shown that the tested value corresponds well with the designed value.

  13. Hepatitis A virus: a test method for virucidal activity.

    Science.gov (United States)

    Wolff, M H; Schmitt, J; Rahaus, M; König, A

    2001-08-01

    Hepatitis A virus (HAV) is closely related to the genus enterovirus. HAV is very stable and resistant to acid pH and elevated temperature, as well as to chemicals and environmental influences. Human poliovirus is still one of the model viruses for testing disinfectants but there are discussions about changing to hepatitis A virus. The purpose of this study was to develop a method for using adapted hepatitis A virus to test hand disinfectants. Using HAV strains HM175/24a and FRhK-4 cytopathic effects were visible rarely, and not before 14 days. To verify virus growth in cells a RT-PCR was developed. Two disinfectants tested did not show the required virucidal activity to satisfy current German guidelines.

  14. A new method for testing Newton's gravitational law

    International Nuclear Information System (INIS)

    Schurr, J.; Klein, N.; Meyer, H.; Piel, H.; Walesch, H.

    1991-01-01

    A new experimental method is reported for determining the gravitational force of a laboratory test mass on a Fabry-Perot microwave resonator. The resonator consists of two Fabry-Perot mirrors suspended as pendulums. Changes of 2·10 -11 m in the pendulum separation can be resolved as a shift of the resonance frequency of the resonator. This limit corresponds to an acceleration of 7·10 -11 m s -2 of one mirror with respect to the other. In a first experiment, the gravitational acceleration generated by a 125 kg test mass was measured as a function of distance in the range of 10 to 15 cm and tested Newton's gravitational law with an accuracy of 1%. No deviation is found. Furthermore, the gravitational constant G is determined with similar precision. (author) 5 refs., 2 figs

  15. Development of fracture toughness test method for nuclear grade graphite

    Energy Technology Data Exchange (ETDEWEB)

    Chang, C. H.; Lee, J. S.; Cho, H. C.; Kim, D. J.; Lee, D. J. [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2006-02-15

    Because of its high strength and stability at very high temperature, as well as very low thermal neutron absorption cross-section, graphite has been widely used as a structural material in Gas Cooled Reactors (GCR). Recently, many countries are developing the Very High Temperature gas cooled Reactor (VHTR) because of the potentials of hydrogen production, as well as its safety and viable economics. In VHTR, helium gas serves as the primary coolant. Graphite will be used as a reflector, moderator and core structural materials. The life time of graphite is determined from dimensional changes due to neutron irradiation, which closely relates to the changes of crystal structure. The changes of both lattice parameter and crystallite size can be easily measured by X-ray diffraction method. However, due to high cost and long time of neutron irradiation test, ion irradiation test is being performed instead in KAERI. Therefore, it is essential to develop the technique for measurement of ion irradiation damage of nuclear graphite. Fracture toughness of nuclear grade graphite is one of the key properties in the design and development of VHTR. It is important not only to evaluate the various properties of candidate graphite but also to assess the integrity of nuclear grade graphite during operation. Although fracture toughness tests on graphite have been performed in many laboratories, there have been wide variations in values of the calculated fracture toughness, due to the differences in the geometry of specimens and test conditions. Hence, standard test method for nuclear graphite is required to obtain the reliable fracture toughness values. Crack growth behavior of nuclear grade graphite shows rising R-curve which means the increase in crack growth resistance as the crack length increases. Crack bridging and microcracking have been proposed to be the dominant mechanisms of rising R-curve behavior. In this paper, the technique to measure the changes of crystallite size and

  16. Well test imaging - a new method for determination of boundaries from well test data

    Energy Technology Data Exchange (ETDEWEB)

    Slevinsky, B.A.

    1997-08-01

    A new method has been developed for analysis of well test data, which allows the direct calculation of the location of arbitrary reservoir boundaries which are detected during a well test. The method is based on elements of ray tracing and information theory, and is centered on the calculation of an instantaneous {open_quote}angle of view{close_quote} of the reservoir boundaries. In the absence of other information, the relative reservoir shape and boundary distances are retrievable in the form of a Diagnostic Image. If other reservoir information, such as 3-D seismic, is available; the full shape and orientation of arbitrary (non-straight line or circular arc) boundaries can be determined in the form of a Reservoir Image. The well test imaging method can be used to greatly enhance the information available from well tests and other geological data, and provides a method to integrate data from multiple disciplines to improve reservoir characterization. This paper covers the derivation of the analytical technique of well test imaging and shows examples of application of the technique to a number of reservoirs.

  17. Applications of Automation Methods for Nonlinear Fracture Test Analysis

    Science.gov (United States)

    Allen, Phillip A.; Wells, Douglas N.

    2013-01-01

    Using automated and standardized computer tools to calculate the pertinent test result values has several advantages such as: 1. allowing high-fidelity solutions to complex nonlinear phenomena that would be impractical to express in written equation form, 2. eliminating errors associated with the interpretation and programing of analysis procedures from the text of test standards, 3. lessening the need for expertise in the areas of solid mechanics, fracture mechanics, numerical methods, and/or finite element modeling, to achieve sound results, 4. and providing one computer tool and/or one set of solutions for all users for a more "standardized" answer. In summary, this approach allows a non-expert with rudimentary training to get the best practical solution based on the latest understanding with minimum difficulty.Other existing ASTM standards that cover complicated phenomena use standard computer programs: 1. ASTM C1340/C1340M-10- Standard Practice for Estimation of Heat Gain or Loss Through Ceilings Under Attics Containing Radiant Barriers by Use of a Computer Program 2. ASTM F 2815 - Standard Practice for Chemical Permeation through Protective Clothing Materials: Testing Data Analysis by Use of a Computer Program 3. ASTM E2807 - Standard Specification for 3D Imaging Data Exchange, Version 1.0 The verification, validation, and round-robin processes required of a computer tool closely parallel the methods that are used to ensure the solution validity for equations included in test standard. The use of automated analysis tools allows the creation and practical implementation of advanced fracture mechanics test standards that capture the physics of a nonlinear fracture mechanics problem without adding undue burden or expense to the user. The presented approach forms a bridge between the equation-based fracture testing standards of today and the next generation of standards solving complex problems through analysis automation.

  18. MODERATOR ELEMENTS FOR UNIFORM POWER NUCLEAR REACTOR

    Science.gov (United States)

    Balent, R.

    1963-03-12

    This patent describes a method of obtaining a flatter flux and more uniform power generation across the core of a nuclear reactor. The method comprises using moderator elements having differing moderating strength. The elements have an increasing amount of the better moderating material as a function of radial and/or axial distance from the reactor core center. (AEC)

  19. Standard test method for measuring pH of soil for use in corrosion testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1995-01-01

    1.1 This test method covers a procedure for determining the pH of a soil in corrosion testing. The principle use of the test is to supplement soil resistivity measurements and thereby identify conditions under which the corrosion of metals in soil may be accentuated (see G 57 - 78 (1984)). 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  20. Integrated circuit test-port architecture and method and apparatus of test-port generation

    Science.gov (United States)

    Teifel, John

    2016-04-12

    A method and apparatus are provided for generating RTL code for a test-port interface of an integrated circuit. In an embodiment, a test-port table is provided as input data. A computer automatically parses the test-port table into data structures and analyzes it to determine input, output, local, and output-enable port names. The computer generates address-detect and test-enable logic constructed from combinational functions. The computer generates one-hot multiplexer logic for at least some of the output ports. The one-hot multiplexer logic for each port is generated so as to enable the port to toggle between data signals and test signals. The computer then completes the generation of the RTL code.