WorldWideScience

Sample records for unified screw locking

  1. First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

    Directory of Open Access Journals (Sweden)

    Leif Claassen

    2017-07-01

    Full Text Available Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis with crossed-screwsor with a nonlocking plate with lag screw. Results: There were four non-unions in crossed-screws patients and one nonunion in non-locked plate group. All the patients in locking plate group achieved union. 90% of the patients were completely or mildly satisfied in locking plate group, whereas this rate was 80% for patients in both crossed screws and non-locking plate groups. Conclusions: Use of dorsal plating for arthrodesis of MTP1 joint either locking or non-locking were associated with high union rate and acceptable and comparable functional outcome. Although nonunion rate was high using two crossed screws but functional outcome was not significantly different compare to dorsal plating. Level of evidence:Ш, retrospective comparative study

  2. Locking screw apparatus and method for underwater remote replacement

    International Nuclear Information System (INIS)

    Balog, L.J.

    1987-01-01

    A method is described for locking in place a screw which secures together first and second structures in the internal region of a nuclear reactor core. The first structure has a screw bore with a counterbore portion formed in an outer surface. The method comprises the steps of: forming a lateral recess in the counterbore portion and spaced from the outer surface, providing an elongated screw having an enlarged shoulder flange and an angular drive head with a lateral width substantially less than that of the counterbore portion, disposing the screw through the screw bore in threaded engagement with the second structure and with the shoulder rotatably seated in the counterbore portion. This provides a locking member having an angular opening and disposing it in the counterbore portion against the flange with the drive head received in the opening for engagement with the locking member to prevent rotation. This deforms a portion of the locking member into the recess for engagement to prevent movement of the locking member with respect to the first structure

  3. Locking screw-plate interface stability in carbon-fibre reinforced polyetheretherketone proximal humerus plates.

    Science.gov (United States)

    Hak, David J; Fader, Ryan; Baldini, Todd; Chadayammuri, Vivek B S

    2017-09-01

    Carbon-fibre reinforced polyetheretherketone (CFR-PEEK) plates have recently been introduced for proximal humerus fracture treatment. The purpose of this study was to compare the locking screw-plate interface stability in CFR-PEEK versus stainless steel (SS) proximal humerus plates. Locking screw mechanical stability was evaluated independently in proximal and shaft plate holes. Stiffness and load to failure were tested for three conditions: (1) on-axis locking screw insertion in CFR-PEEK versus SS plates, (2) on-axis locking screw insertion, removal, and reinsertion in CFR-PEEK plates, and (3) 10-degree off-axis locking screw insertion in CFR-PEEK plates. Cantilever bending at a rate of 1 mm/minute was produced by an Instron machine and load-displacement data recorded. Shaft locking screw load to failure was significantly greater in CFR-PEEK plates compared to SS plates (746.4 ± 89.7 N versus 596.5 ± 32.6 N, p PEEK plates (p PEEK plates. The mechanical stability of locking screws in CFR-PEEK plates is comparable or superior to locking screws in SS plates.

  4. [Development of polyaxial locking plate screw system of sacroiliac joint].

    Science.gov (United States)

    Fan, Weijie; Xie, Xuesong; Zhou, Shuping; Zhang, Yonghu

    2014-09-01

    To develop an instrument for sacroiliac joint fixation with less injury and less complications. Firstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups: group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. According to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P 0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P 0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. The polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw

  5. Drag and Torque on Locked Screw Propeller

    Directory of Open Access Journals (Sweden)

    Tomasz Tabaczek

    2014-09-01

    Full Text Available Few data on drag and torque on locked propeller towed in water are available in literature. Those data refer to propellers of specific geometry (number of blades, blade area, pitch and skew of blades. The estimation of drag and torque of an arbitrary propeller considered in analysis of ship resistance or propulsion is laborious. The authors collected and reviewed test data available in the literature. Based on collected data there were developed the empirical formulae for estimation of hydrodynamic drag and torque acting on locked screw propeller. Supplementary CFD computations were carried out in order to prove the applicability of the formulae to modern moderately skewed screw propellers.

  6. The best location for proximal locking screw for femur interlocking nailing: A biomechanical study

    Directory of Open Access Journals (Sweden)

    Ahmet A Karaarslan

    2016-01-01

    Conclusion: According to our findings, there is twice as much difference in locking screw bending resistance between these two application levels. To avoid proximal locking screw deformation, locking screws should be placed in the level of the lesser trochanter in nailing of 1/3 middle and distal femur fractures.

  7. A locking compression plate versus the gold-standard non-locking plate with lag screw for first metatarsophalangeal fusion: A biomechanical comparison.

    Science.gov (United States)

    Mandell, Daniel; Karbassi, John; Zhou, Hanbing; Burroughs, Brian; Aurigemma, Philip; Patel, Abhay R

    2018-03-01

    The treatment of end-stage first metatarso-phalangeal joint (MTP) arthritis has been arthrodesis. A dorsal non-locking plate with a lag screw has been the standard traditional fixation method. This study compares the biomechanical strength of a locking compression plate (LCP) with and without internal compression versus this known gold standard. In group 1, six matched pairs of cadaver great toes were used to compare the standard non-locking dorsal plate and 3.5mm lag screw to an anatomic locking compression plate in which a lag screw was utilized rather than the internal compression features of the plate. In group 2, another six matched pairs of cadaver great toes were used to compare the gold standard to the locking compression plate, utilizing the plate's internal compression feature instead of a lag screw. A material testing system (MTS) machine applied loads to the MTP joints and measured displacement and stiffness of the constructs. The stiffness of the constructs (Young's modulus) was calculated from the force-displacement curves, and the displacement was measured. The locking compression plate group that used the compression features of the plate, without the lag screw, had less joint displacement and higher stiffness than control (p<0.05). The same plating construct in which a lag screw was used rather than internal compression of the plate was found to be stiffer than the control (p<0.05), but displacement was not statistically significant. The results suggest that a locking compression plate alone provides the stiffest construct for a first MTP joint fusion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Tool for cutting locking cups from guide tube mounting screws in a nuclear reactor

    International Nuclear Information System (INIS)

    Nee, J.D.; Hahn, J.J.

    1987-01-01

    This patent describes an apparatus for freeing a socket-head screw from a locking cup therefor in a reactor cavity, wherein the locking cup includes a fixed cylindrical side wall encircling the side surface of the screw head and an annular end wall overlying the outer end surface of the screw head. The apparatus consists of: frame means, cylindrical cutter means having a longitudinal axis and having a frustoconical cutting surface with an inner diameter less than the inner diameter of the locking cup side wall and with an outer diameter greater than the outer diameter of the locking cup side wall, and drive means carried by the frame means and coupled to the cutter means for effecting rotation thereof about the axis, the rotating cutter means are operable for severing the locking cup end wall from the locking cup side wall at the junction therebetween when the cutter means is moved against the locking cup substantially coaxially therewith

  9. The effect of polyethylene creep on tibial insert locking screw loosening and back-out in prosthetic knee joints.

    Science.gov (United States)

    Sanders, Anthony P; Raeymaekers, Bart

    2014-10-01

    A prosthetic knee joint typically comprises a cobalt-chromium femoral component that articulates with a polyethylene tibial insert. A locking screw may be used to prevent micromotion and dislodgement of the tibial insert from the tibial tray. Screw loosening and back-out have been reported, but the mechanism that causes screw loosening is currently not well understood. In this paper, we experimentally evaluate the effect of polyethylene creep on the preload of the locking screw. We find that the preload decreases significantly as a result of polyethylene creep, which reduces the torque required to loosen the locking screw. The torque applied to the tibial insert due to internal/external rotation within the knee joint during gait could thus drive locking screw loosening and back-out. The results are very similar for different types of polyethylene. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures.

    Science.gov (United States)

    Röderer, Götz; Scola, Alexander; Schmölz, Werner; Gebhard, Florian; Windolf, Markus; Hofmann-Fliri, Ladina

    2013-10-01

    Proximal humerus fracture fixation can be difficult because of osteoporosis making it difficult to achieve stable implant anchorage in the weak bone stock even when using locking plates. This may cause implant failure requiring revision surgery. Cement augmentation has, in principle, been shown to improve stability. The aim of this study was to investigate whether augmentation of particular screws of a locking plate aimed at a region of low bone quality is effective in improving stability in a proximal humerus fracture model. Twelve paired human humerus specimens were included. Quantitative computed tomography was performed to determine bone mineral density (BMD). Local bone quality in the direction of the six proximal screws of a standard locking plate (PHILOS, Synthes) was assessed using mechanical means (DensiProbe™). A three-part fracture model with a metaphyseal defect was simulated and fixed with the plate. Within each pair of humeri the two screws aimed at the region of the lowest bone quality according to the DensiProbe™ were augmented in a randomised manner. For augmentation, 0.5 ml of bone cement was injected in a screw with multiple outlets at its tip under fluoroscopic control. A cyclic varus-bending test with increasing upper load magnitude was performed until failure of the screw-bone fixation. The augmented group withstood significantly more load cycles. The correlation of BMD with load cycles until failure and BMD with paired difference in load cycles to failure showed that augmentation could compensate for a low BMD. The results demonstrate that augmentation of screws in locked plating in a proximal humerus fracture model is effective in improving primary stability in a cyclic varus-bending test. The augmentation of two particular screws aimed at a region of low bone quality within the humeral head was almost as effective as four screws with twice the amount of bone cement. Screw augmentation combined with a knowledge of the local bone quality

  11. Biomechanical Comparison of 3 Inferiorly Directed Versus 3 Superiorly Directed Locking Screws on Stability in a 3-Part Proximal Humerus Fracture Model.

    Science.gov (United States)

    Donohue, David M; Santoni, Brandon G; Stoops, T Kyle; Tanner, Gregory; Diaz, Miguel A; Mighell, Mark

    2018-06-01

    To quantify the stability of 3 points of inferiorly directed versus 3 points of superiorly directed locking screw fixation compared with the full contingent of 6 points of locked screw fixation in the treatment of a 3-part proximal humerus fracture. A standardized 3-part fracture was created in 10 matched pairs (experimental groups) and 10 nonmatched humeri (control group). Osteosynthesis was performed using 3 locking screws in the superior hemisphere of the humeral head (suspension), 3 locking screws in the inferior hemisphere (buttress), or the full complement of 6 locking screws (control). Specimens were tested in varus cantilever bending (7.5 Nm) to 10,000 cycles or failure. Construct survival (%) and the cycles to failure were compared. Seven of 10 controls survived the 10,000-cycle runout (70%: 8193 average cycles to failure). No experimental constructs survived the 10,000-cycle runout. Suspension and buttress screw groups failed an average of 331 and 516 cycles, respectively (P = 1.00). The average number of cycles to failure and the number of humeri surviving the 10,000-cycle runout were greater in the control group than in the experimental groups (P ≤ 0.006). Data support the use of a full contingent of 6 points of locking screw fixation over 3 superior or 3 inferior points of fixation in the treatment of a 3-part proximal humerus fracture with a locking construct. No biomechanical advantage to the 3 buttress or 3 suspension screws used in isolation was observed.

  12. The mechanical benefit of medial support screws in locking plating of proximal humerus fractures.

    Directory of Open Access Journals (Sweden)

    Wen Zhang

    Full Text Available BACKGROUND: The purpose of this study was to evaluate the biomechanical advantages of medial support screws (MSSs in the locking proximal humeral plate for treating proximal humerus fractures. METHODS: Thirty synthetic left humeri were randomly divided into 3 subgroups to establish two-part surgical neck fracture models of proximal humerus. All fractures were fixed with a locking proximal humerus plate. Group A was fixed with medial cortical support and no MSSs; Group B was fixed with 3 MSSs but without medial cortical support; Group C was fixed with neither medial cortical support nor MSSs. Axial compression, torsional stiffness, shear stiffness, and failure tests were performed. RESULTS: Constructs with medial support from cortical bone showed statistically higher axial and shear stiffness than other subgroups examined (P<0.0001. When the proximal humerus was not supported by medial cortical bone, locking plating with medial support screws exhibited higher axial and torsional stiffness than locking plating without medial support screws (P ≤ 0.0207. Specimens with medial cortical bone failed primarily by fracture of the humeral shaft or humeral head. Specimens without medial cortical bone support failed primarily by significant plate bending at the fracture site followed by humeral head collapse or humeral head fracture. CONCLUSIONS: Anatomic reduction with medial cortical support was the stiffest construct after a simulated two-part fracture. Significant biomechanical benefits of MSSs in locking plating of proximal humerus fractures were identified. The reconstruction of the medial column support for proximal humerus fractures helps to enhance mechanical stability of the humeral head and prevent implant failure.

  13. Dynamic locking screw improves fixation strength in osteoporotic bone: an in vitro study on an artificial bone model.

    Science.gov (United States)

    Pohlemann, Tim; Gueorguiev, Boyko; Agarwal, Yash; Wahl, Dieter; Sprecher, Christoph; Schwieger, Karsten; Lenz, Mark

    2015-04-01

    The novel dynamic locking screw (DLS) was developed to improve bone healing with locked-plate osteosynthesis by equalising construct stiffness at both cortices. Due to a theoretical damping effect, this modulated stiffness could be beneficial for fracture fixation in osteoporotic bone. Therefore, the mechanical behaviour of the DLS at the screw-bone interface was investigated in an artificial osteoporotic bone model and compared with conventional locking screws (LHS). Osteoporotic surrogate bones were plated with either a DLS or a LHS construct consisting of two screws and cyclically axially loaded (8,500 cycles, amplitude 420 N, increase 2 mN/cycle). Construct stiffness, relative movement, axial screw migration, proximal (P) and distal (D) screw pullout force and loosening at the bone interface were determined and statistically evaluated. DLS constructs exhibited a higher screw pullout force of P 85 N [standard deviation (SD) 21] and D 93 N (SD 12) compared with LHS (P 62 N, SD 28, p = 0.1; D 57 N, SD 25, p LHS (p = 0.01). DLS constructs showed significantly lower axial construct stiffness (403 N/mm, SD 21, p LHS (529 N/mm, SD 27; 0.8 mm, SD 0.04). Based on the model data, the DLS principle might also improve in vivo plate fixation in osteoporotic bone, providing enhanced residual holding strength and reducing screw cutout. The influence of pin-sleeve abutment still needs to be investigated.

  14. Unified Singularity Modeling and Reconfiguration of 3rTPS Metamorphic Parallel Mechanisms with Parallel Constraint Screws

    Directory of Open Access Journals (Sweden)

    Yufeng Zhuang

    2015-01-01

    Full Text Available This paper presents a unified singularity modeling and reconfiguration analysis of variable topologies of a class of metamorphic parallel mechanisms with parallel constraint screws. The new parallel mechanisms consist of three reconfigurable rTPS limbs that have two working phases stemming from the reconfigurable Hooke (rT joint. While one phase has full mobility, the other supplies a constraint force to the platform. Based on these, the platform constraint screw systems show that the new metamorphic parallel mechanisms have four topologies by altering the limb phases with mobility change among 1R2T (one rotation with two translations, 2R2T, and 3R2T and mobility 6. Geometric conditions of the mechanism design are investigated with some special topologies illustrated considering the limb arrangement. Following this and the actuation scheme analysis, a unified Jacobian matrix is formed using screw theory to include the change between geometric constraints and actuation constraints in the topology reconfiguration. Various singular configurations are identified by analyzing screw dependency in the Jacobian matrix. The work in this paper provides basis for singularity-free workspace analysis and optimal design of the class of metamorphic parallel mechanisms with parallel constraint screws which shows simple geometric constraints with potential simple kinematics and dynamics properties.

  15. Effect of screw position on single cycle to failure in bending and torsion of a locking plate-rod construct in a synthetic feline femoral gap model.

    Science.gov (United States)

    Niederhäuser, Simone K; Tepic, Slobodan; Weber, Urs T

    2015-05-01

    To evaluate the effect of screw position on strength and stiffness of a combination locking plate-rod construct in a synthetic feline femoral gap model. 30 synthetic long-bone models derived from beechwood and balsa wood. 3 constructs (2 locking plate-rod constructs and 1 locking plate construct; 10 specimens/construct) were tested in a diaphyseal bridge plating configuration by use of 4-point bending and torsion. Variables included screw position (near the fracture gap and far from the fracture gap) and application of an intramedullary pin. Constructs were tested to failure in each loading mode to determine strength and stiffness. Failure was defined as plastic deformation of the plate or breakage of the bone model or plate. Strength, yield angle, and stiffness were compared by use of a Wilcoxon test. Placement of screws near the fracture gap did not increase bending or torsional stiffness in the locking plate-rod constructs, assuming the plate was placed on the tension side of the bone. Addition of an intramedullary pin resulted in a significant increase in bending strength of the construct. Screw positioning did not have a significant effect on any torsion variables. Results of this study suggested that, in the investigated plate-rod construct, screw insertion adjacent to the fracture lacked mechanical advantages over screw insertion at the plate ends. For surgeons attempting to minimize soft tissue dissection, the decision to make additional incisions for screw placement should be considered with even more caution.

  16. Training Distal Locking Screw Insertion Skills to Novice Trainees: A Comparison Between Fluoroscopic- and Electromagnetic-Guided Techniques.

    Science.gov (United States)

    Leroux, Timothy; Khoshbin, Amir; Nousiainen, Markku T

    2015-10-01

    To compare the effect fluoroscopy or electromagnetic (EM) guidance has on the learning of locking screw insertion in tibial nails in surgical novices. A randomized, prospective, controlled trial was conducted involving 18 surgical trainees with no prior experience inserting locking screws in intramedullary nails. After a training session using fluoroscopy, participants underwent a pretest using fluoroscopic guidance. Participants were then randomized into either the fluoroscopy or EM group and were further trained using their respective technique. Post, retention, and transfer tests were conducted. Outcomes included task completion, drill attempts, screw changes, and radiation time. Intragroup comparisons revealed that the EM group used significantly less drill attempts during the post and retention tests compared with the pretest (P = 0.016 and P = 0.016, respectively). Intergroup comparisons revealed that the EM group was (1) more likely to complete the task during the retention test (P = 0.043) and (2) had significantly less radiation time during the post and retention tests (P = 0.002 and P = 0.003, respectively). Radiation time in the EM group during the transfer test increased to a level equal to what the fluoroscopy group used during the post and retention tests (P = 0.71 and P = 0.92, respectively). No other significant between-group differences occurred. EM guidance may be safely used to assist in the training of surgical novices in the skill of distal locking screw insertion. Not only does this technology significantly improve the ability to complete the task and decrease radiation use but also it does so without compromising skill acquisition. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  17. Biomechanics of far cortical locking.

    Science.gov (United States)

    Bottlang, Michael; Feist, Florian

    2011-02-01

    The development of far cortical locking (FCL) was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biologic fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have been shown to enhance fixation and healing of fractures: flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80% to 88% to actively promote callus proliferation similar to an external fixator. Load is evenly distributed between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by the S-shaped flexion of FCL screws promotes symmetric callus formation. In combination, these features of FCL constructs have been shown to induce more callus and to yield significantly stronger and more consistent healing compared with standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biologic healing response of external fixators.

  18. A new palatal distractor device for bodily movement of maxillary bones by rigid self-locking miniplates and screws system.

    Science.gov (United States)

    Cortese, Antonio; Savastano, Mauro; Cantone, Antonio; Claudio, Pier Paolo

    2013-07-01

    A new palatal distractor device for bodily movement of the maxillary bones after complete segmented Le Fort I osteotomy for 1-stage transversal distraction and tridimensional repositioning on 1 patient is presented. The new distractor has an intrinsic tridimensional rigidity also in the fixation system by self-locking miniplates and screws for better control of the 2 maxillary fragments during distraction. Le Fort I distraction and repositioning procedure in association with a bilateral sagittal split osteotomy were performed on 1 patient with complete solution of the cross-bite and class III malocclusion. Results of dental and cephalometric analysis performed before surgery (T1), after surgery and distraction time (T2), and 18 months after surgery and orthodontic appliance removal (T3) are reported. No complications were encountered using the new distractor device. Advantages of this device and technique are presented including improved rigidity of both distraction (jackscrew) and fixation (4 self-locking miniplates and screws) systems resulting in complete control of the position of the 2 maxillary fragments during distraction and surgery. In addition, this new device allows resuming palatal distraction in the event of cross-bite relapse without causing dental-related problems or the risks of screw slackening.

  19. [Comparison of clinical effect on locking plate for proximal humeral fracture with or without application of inferomedial screws].

    Science.gov (United States)

    Guo, Xiu-wu; Fan, Jian; Yuan, Feng

    2016-06-01

    To compare clinical outcomes of locking plate for proximal humeral fracture whether application of inferomedial screws. From January 2012 to July 2013, 46 patients with proximal humeral fracture underwent locking plates were retrospectively analyzed. There were 25 males and 21 females aged from 29 to 80 years old with an average of 55.1 years old. Among them, 25 patients were treated with inferomedial screws (support group), including 13 males and 12 females aged from 38 to 80 years old with an average of (55.8 ± 11.8) years old; 8 cases were part two fracture,10 cases were part three fracture and 7 cases were part four fracture according to Neer classification. Twenty-one patients were treated without inferomedial screws (non-support group), including 12 males and 9 females aged from 29 to 79 years old with an average of (54.2 ± 14.8)years old; 6 cases were part two fracture, 9 cases were part three fracture and 6 cases were part four fracture according to Neer classification. Operative time, fracture healing time and complications were observed and compared, Neer scoring of shoulder joint were used to evaluate clinical effect. All patients were followed up from 12 to 41 months with an average of 15.6 months. Operative time and fracture healing time in support group was (1.6 ± 0.4) h and (3.0 ± 0.6) months, and (1.5 ± 0.4) h and (3.1 ± 0.6) months in non-support group, while there was no statistical difference in operative time and fracture healing time between two groups. There was significant differences in Neer score between support group (89.7± 4.9) and non-support group (83.1 ± 7.1). No complication occurred in support group,while 4 cases occurred complications in non-support group. Locking plate with inferomedial screws for proximal humeral fracture has advantages of stable fixation, less complications, quick recovery of function and satisfied clinical effect.

  20. Aspects of internal fixation of fractures in porotic bone. Principles, technologies and procedures using locked plate screws.

    Science.gov (United States)

    Perren, S M; Linke, B; Schwieger, K; Wahl, D; Schneider, E

    2005-01-01

    Fractures of the bones of elderly people occur more often and have a more important effect because of a generally diminished ability to coordinate stance and walking. These fractures occur at a lower level of load because of lack of strength of the porotic bone. Prompt recovery of skeletal support function is essential to avoid respiratory and circulatory complications in the elderly. To prevent elderly people from the risks of being bedridden, demanding internal fixation of fractures is required. The weak porotic bone and the high level of uncontrolled loading after internal fixation pose complex problems. A combination of several technical elements of design, application and aftercare in internal fixation are proposed. Internal fixators with locked screws improve the biology and the mechanics of internal fixation. When such fixators are used as elevated splints they may stimulate early callus formation because of their flexibility, the limit of flexibility being set by the demands of resistance and function of the limb. Our own studies of triangulation of locked screws have demonstrated their beneficial effects and unexpected limitations.

  1. DLS 5.0--the biomechanical effects of dynamic locking screws.

    Directory of Open Access Journals (Sweden)

    Stefan Döbele

    Full Text Available INTRODUCTION: Indirect reduction of dia-/metaphyseal fractures with minimally invasive implant application bridges the fracture zone in order to protect the soft-tissue and blood supply. The goal of this fixation strategy is to allow stable motion at the fracture site to achieve indirect bone healing with callus formation. However, concerns have arisen that the high axial stiffness and eccentric position of locked plating constructs may suppress interfragmentary motion and callus formation, particularly under the plate. The reason for this is an asymmetric fracture movement. The biological need for sufficient callus formation and secondary bone healing is three-dimensional micro movement in the fracture zone. The DLS was designed to allow for increased fracture site motion. The purpose of the current study was to determine the biomechanical effect of the DLS_5.0. METHODS: Twelve surrogate bone models were used for analyzing the characteristics of the DLS_5.0. The axial stiffness and the interfragmentary motion of locked plating constructs with DLS were compared to conventional constructs with Locking Head Screws (LS_5.0. A quasi-static axial load of 0 to 2.5 kN was applied. Relative motion was measured. RESULTS: The dynamic system showed a biphasic axial stiffness distribution and provided a significant reduction of the initial axial stiffness of 74.4%. Additionally, the interfragmentary motion at the near cortex increased significantly from 0.033 mm to 0.210 mm (at 200N. CONCLUSIONS: The DLS may ultimately be an improvement over the angular stable plate osteosynthesis. The advantages of the angular stability are not only preserved but even supplemented by a dynamic element which leads to homogenous fracture movement and to a potentially uniform callus distribution.

  2. Complication with Removal of a Lumbar Spinal Locking Plate

    Directory of Open Access Journals (Sweden)

    Brooke Crawford

    2015-01-01

    Full Text Available Introduction. The use of locking plate technology for anterior lumbar spinal fusion has increased stability of the vertebral fusion mass over traditional nonconstrained screw and plate systems. This case report outlines a complication due to the use of this construct. Case. A patient with a history of L2 corpectomy and anterior spinal fusion presented with discitis at the L4/5 level and underwent an anterior lumbar interbody fusion (ALIF supplemented with a locking plate placed anterolaterally for stability. Fifteen months after the ALIF procedure, he returned with a hardware infection. He underwent debridement of the infection site and removal of hardware. Results. Once hardware was exposed, removal of the locking plate screws was only successful in one out of four screws using a reverse thread screw removal device. Three of the reverse thread screw removal devices broke in attempt to remove the subsequent screws. A metal cutting drill was then used to break hoop stresses associated with the locking device and the plate was removed. Conclusion. Anterior locking plates add significant stability to an anterior spinal fusion mass. However, removal of this hardware can be complicated by the inherent properties of the design with significant risk of major vascular injury.

  3. A Unified Impedance Model of Voltage-Source Converters with Phase-Locked Loop Effect

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Harnefors, Lennart; Blaabjerg, Frede

    2016-01-01

    This paper proposes a unified impedance model for analyzing the effect of Phase-Locked Loop (PLL) on the stability of grid-connected voltage-source converters. In the approach, the dq-frame impedance model is transformed into the stationary αβ-frame by means of complex transfer functions...... and complex space vectors, which not only predicts the stability impact of the PLL, but reveals also its frequency coupling effect in the phase domain. Thus, the impedance models previously developed in the different domains can be unified. Moreover, the impedance shaping effects of PLL are structurally...... characterized for the current control in the rotating dq-frame and the stationary αβ-frame. Case studies based on the unified impedance model are presented, which are then verified in the time-domain simulations and experiments. The results closely correlate with the impedance-based analysis....

  4. The strength of polyaxial locking interfaces of distal radius plates.

    Science.gov (United States)

    Hoffmeier, Konrad L; Hofmann, Gunther O; Mückley, Thomas

    2009-10-01

    Currently available polyaxial locking plates represent the consequent enhancement of fixed-angle, first-generation locking plates. In contrast to fixed-angle locking plates which are sufficiently investigated, the strength of the new polyaxial locking options has not yet been evaluated biomechanically. This study investigates the mechanical strength of single polyaxial interfaces of different volar radius plates. Single screw-plate interfaces of the implants Palmar 2.7 (Königsee Implantate und Instrumente zur Osteosynthese GmbH, Allendorf, Germany), VariAx (Stryker Leibinger GmbH & Co. KG, Freiburg, Germany) und Viper (Integra LifeSciences Corporation, Plainsboro, NJ, USA) were tested by cantilever bending. The strength of 0 degrees, 10 degrees and 20 degrees screw locking angle was obtained during static and dynamic loading. The Palmar 2.7 interfaces showed greater ultimate strength and fatigue strength than the interfaces of the other implants. The strength of the VariAx interfaces was about 60% of Palmar 2.7 in both, static and dynamic loading. No dynamic testing was applied to the Viper plate because of its low ultimate strength. By static loading, an increase in screw locking angle caused a reduction of strength for the Palmar 2.7 and Viper locking interfaces. No influence was observed for the VariAx locking interfaces. During dynamic loading; angulation had no influence on the locking strength of Palmar 2.7. However, reduction of locking strength with increasing screw angulation was observed for VariAx. The strength of the polyaxial locking interfaces differs remarkably between the examined implants. Depending on the implant an increase of the screw locking angle causes a reduction of ultimate or fatigue strength, but not in all cases a significant impact was observed.

  5. Treating Simple Tibia Fractures with Poly-DL-Lactic Acid Screw as a ...

    African Journals Online (AJOL)

    Purpose: To investigate the curative effect of poly-DL-lactic acid (PDLLA) absorbable screw as a locked intramedullary nail for simple tibia fractures. Methods: In this study, 35 patients treated with the PDLLA screw were observed, and another 35 patients treated with a traditional locking intramedullary nail were treated as ...

  6. A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

    Directory of Open Access Journals (Sweden)

    Prakash Jayakumar

    2015-04-01

    Full Text Available Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking screw, which must also avoid the olecranon, coronoid, and radial fossae. We describe 3 patients (ages 27, 49, and 73 years with a bicolumnar fracture of the distal humerus where very short distal locking screws were used. Intra-articular screw placement was avoided but loss of fixation occurred in two patients and a third was treated with a prolonged period of immobilization. We postulate that fixed-angle screw trajectories may make it difficult for the surgeon to place screws of adequate length in this anatomically confined region, and may lead to insufficient distal fixation. Surgical tactics should include placement of as many screws as possible into the distal fragment, as long as possible, and that each screw pass through a plate without necessarily locking in.

  7. Filling Open Screw Holes in the Area of Metaphyseal Comminution Does Not Affect Fatigue Life of the Synthes Variable Angle Distal Femoral Locking Plate in the AO/OTA 33-A3 Fracture Model.

    Science.gov (United States)

    Grau, Luis; Collon, Kevin; Alhandi, Ali; Kaimrajh, David; Varon, Maria; Latta, Loren; Vilella, Fernando

    2018-06-01

    The aim of this study is to evaluate the biomechanical effect of filling locking variable angle (VA) screw holes at the area of metaphyseal fracture comminution in a Sawbones® (Sawbones USA, Vashon, Washington) model (AO/OTA 33A-3 fracture) using a Synthes VA locking compression plate (LCP) (Depuy Synthes, Warsaw, Indiana). Seven Sawbones® femur models had a Synthes VA-LCP placed as indicated by the manufacturers technique. A 4cm osteotomy was then created to simulate an AO/OTA 33-A3 femoral fracture pattern with metaphyseal comminution. The control group consisted of four constructs in which the open screw holes at the area of comminution were left unfilled; the experimental group consisted of three constructs in which the VA screw holes were filled with locking screws. One of the control constructs was statically loaded to failure at a rate of 5mm/min. A value equal to 75% of the ultimate load to failure was used as the loading force for fatigue testing of 250,000 cycles at 3Hz. Cycles to failure was recorded for each construct and averages were compared between groups. The average number of cycles to failure in the control and experimental groups were 37524±8187 and 43304±23835, respectively (p=0.72). No significant difference was observed with respect to cycles to failure or mechanism of failure between groups. In all constructs in both the control and experimental groups, plate failure reproducibly occurred with cracks through the variable angle holes in the area of bridged comminution. The Synthes VA-LCP in a simulated AO/OTA 33-A3 comminuted metaphyseal femoral fracture fails in a reproducible manner at the area of comminution through the "honeycomb" VA screw holes. Filling open VA screw holes at the site of comminution with locking screws does not increase fatigue life of the Synthes VA-LCP in a simulated AO/OTA 33-A3 distal femoral fracture. Further studies are necessary to determine whether use of this particular plate is contraindicated when bridging

  8. Locking plate fixation for proximal humerus fractures.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2012-02-01

    Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for proximal humeral fractures should involve minimal soft tissue dissection and achieve anatomic reduction of the head complex with sufficient stability to allow for early shoulder mobilization. This article reviews various treatment options, in particular locking plate fixation. Locking plate fixation is associated with a high complication rate, such as avascular necrosis (7.9%), screw cutout (11.6%), and revision surgery (13.7%). These complications are frequently due to the varus deformation of the humeral head. Strategic screw placement in the humeral head would minimize the possibility of loss of fracture reduction and potential hardware complications. Locking plate fixation is a good surgical option for the management of proximal humerus fractures. Complications can be avoided by using better bone stock and by careful screw placement in the humeral head.

  9. The Advanced Thread-Locking Mechanism

    Science.gov (United States)

    Weiss, Wolfgang

    2005-12-01

    Locking of threaded members is accomplished by a wide variety of engineering solutions. Generally, in terms of separate locking devices or by built-in locking features such as friction generating means.In regard of space flight vehicles, threaded joints are subject to severe vibration loads during launch, maneuvering, and reentry. This requires fastening systems which are capable to join structural members and attach accessories or equipment in a secure manner. However, manned spacecraft and especially payload components will be subject to installation activity during orbital or interstellar flight maintenance, repair, or mission modification. This, in turn, requires fast separation and engaging of the concerned fasteners, yet providing performance characteristics for high reliable and safe joints.The further described Advanced Thread Locking Mechanism (ATLM) has been developed to combine the merits of both, safe joining technique and a fast installation process. The ATLM uses a freewheel which is securely installed in one part of the threaded member and releasable coupled with the engaged counterpart. While screwing the threaded members together, once coupled, the freewheel will allow free mating of the threaded members including torquing to the desired value. The moment, the pair of threaded fasteners is forced to unscrew (by intended or unintended occurrence of torque in the undoing direction) the freewheel does lock instantly. Disengaging the coupling between the members of the threaded joint takes a separate release action.Owing to the nature of the ATLM, there are a number of design variants ready for implementation.Threaded fasteners in ATLM design are highly recommended for mechanical joints subject to fastening and unfastening during Extra Vehicular Activity (EVA) in course of space flight operations. This is justified through:1. Threaded members mate free running, thus, torque values preset at the wrenching tool are not influenced by varying prevailing

  10. Comparative evaluation of 2.3 mm locking plate system vs conventional 2.0 mm non locking plate system for mandibular condyle fracture fixation: a seven year retrospective study.

    Science.gov (United States)

    Zhang, J; Wang, X; Wu, R-H; Zhuang, Q-W; Gu, Q P; Meng, J

    2015-01-01

    This retrospective study evaluated the efficacy of a 2.3 mm locking plate/screw system compared with a 2.0-mm non-locking plate/screw system in fixation of isolated non comminuted mandibular condyle fractures. Surgical records of 101 patients who received either a 2.3 mm locking plate (group A, n = 51) or 2.0 mm non locking plate (group B, n = 50) were analyzed. All patients were followed up to a minimum of 6 months postoperatively and evaluated for hardware related complications, occlusal stability, need for and duration of MMF and mandibular functional results. Four complications occurred in the locking group and eighteen in the non locking group with complication rates equalling 8% and 36% respectively. When comparing the overall results according to plates used, the χ2 test showed a statistically significant difference between the locking and non locking plates (p Mandibular condyle fractures treated with a 2.3 mm locking plate exhibited stable osteosynthesis, were associated with minimal complications and resulted in acceptable mandibular range of motion compared with a 2.0 mm non locking plate.

  11. A geometrical introduction to screw theory

    International Nuclear Information System (INIS)

    Minguzzi, E

    2013-01-01

    This work introduces screw theory, a venerable but little known theory aimed at describing rigid body dynamics. This formulation of mechanics unifies in the concept of screw the translational and rotational degrees of freedom of the body. It captures a remarkable mathematical analogy between mechanical momenta and linear velocities, and between forces and angular velocities. For instance, it clarifies that angular velocities should be treated as applied vectors and that, under the composition of motions, they sum with the same rules of applied forces. This work provides a short and rigorous introduction to screw theory intended for an undergraduate and general readership. (paper)

  12. Monoaxial versus polyaxial locking systems: a biomechanical analysis of different locking systems for the fixation of proximal humeral fractures.

    Science.gov (United States)

    Zettl, Ralph; Müller, Thorben; Topp, Tobias; Lewan, Ulrike; Krüger, Antonio; Kühne, Christian; Ruchholtz, Steffen

    2011-08-01

    The development of locking plate systems has led to polyaxial screws and new plate designs. This study compares monoaxial head locking screws (PHILOS© by Synthes) and a new generation of polyaxial locking screws (NCB-LE© by Zimmer) with respect to biomechanical stability. On nine pairs of randomised formalin fixed humerus specimens, standardised osteotomies and osteosyntheses with nine monoaxial (group A) und nine polyaxial (group B) plate/screw systems were performed. A material testing machine by Instron (M-10 14961-DE) was used for cyclic stress tests and crash tests until defined breakup criteria as endpoints were reached. After axial cyclic stress 200 times at 90 N, plastic deformation was 1.02 mm in group A and 1.25 mm in group B. After the next cycle using 180 N the additional deformation averaged 0.23 mm in group A and 0.39 mm in group B. The deformation using 450 N was 0.72 mm in group A compared to 0.92 mm in group B. The final full power test resulted in a deformation average of 0.49 mm in group A and 0.63 mm in group B after 2,000 cycles using 450 N. When reaching the breakup criteria the plastic deformation of the NCB plate was 9.04 mm on average. The PHILOS plate was similarly deformed by 9.00 mm. As a result of the crash test, in group A the screws pulled out of the humeral head four times whereas the shaft broke one time and another time the implant was ripped out. The gap was closed four times. In group B, there were three cases of screw cut-through, four shaft fractures/screw avulsions from the shaft and two cases of gap closure. The two systems resist the cyclic duration tests and the increasing force tests in a similar manner. The considerable clinical benefits of the polyaxial system are enhanced by equal biomechanical performance.

  13. Comparison of multiple linear regression and artificial neural network in developing the objective functions of the orthopaedic screws.

    Science.gov (United States)

    Hsu, Ching-Chi; Lin, Jinn; Chao, Ching-Kong

    2011-12-01

    Optimizing the orthopaedic screws can greatly improve their biomechanical performances. However, a methodical design optimization approach requires a long time to search the best design. Thus, the surrogate objective functions of the orthopaedic screws should be accurately developed. To our knowledge, there is no study to evaluate the strengths and limitations of the surrogate methods in developing the objective functions of the orthopaedic screws. Three-dimensional finite element models for both the tibial locking screws and the spinal pedicle screws were constructed and analyzed. Then, the learning data were prepared according to the arrangement of the Taguchi orthogonal array, and the verification data were selected with use of a randomized selection. Finally, the surrogate objective functions were developed by using either the multiple linear regression or the artificial neural network. The applicability and accuracy of those surrogate methods were evaluated and discussed. The multiple linear regression method could successfully construct the objective function of the tibial locking screws, but it failed to develop the objective function of the spinal pedicle screws. The artificial neural network method showed a greater capacity of prediction in developing the objective functions for the tibial locking screws and the spinal pedicle screws than the multiple linear regression method. The artificial neural network method may be a useful option for developing the objective functions of the orthopaedic screws with a greater structural complexity. The surrogate objective functions of the orthopaedic screws could effectively decrease the time and effort required for the design optimization process. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  14. Hollow Mill for Extraction of Stripped Titanium Screws: An Easy, Quick, and Safe Technique

    OpenAIRE

    Gupta, Ravi; Singh, Harpreet; Singh, Amit; Garg, Sudhir

    2014-01-01

    Removal of jammed titanium screws can be difficult due to the problem of stripping of the hexagonal heads of the screws. We present a technique of extraction of stripped screws with the use of a standard 4.5 mm stainless steel hollow mill in a patient of peri-implant fracture of the radius fixed with a titanium locking plate 2 years back. The technique is quick, safe, and cost effective.

  15. Hollow Mill for Extraction of Stripped Titanium Screws: An Easy ...

    African Journals Online (AJOL)

    countries. The known alternative in such condition is ... Key words: Hollow mill, stripped screws, titanium locked plates ... used a locally manufactured stainless steel hollow mill, ... head ‑ plate hole” assembly as a mono‑block single unit. In.

  16. a simple technique for on-table confirmation of locking screw ...

    African Journals Online (AJOL)

    2012-09-06

    Sep 6, 2012 ... Background: Locked intramedullary nailing is the standard of care for femoral and tibial shaft fractures. Correct placement of locking ... It can be used with any cannulated nailing system. It is simple, in-expensive and ... include computer assisted navigation systems (3), as well as use of devices that use a ...

  17. Clinical Outcomes after Open Locked Intramedullary Nailing of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... above who presented within 2 weeks of sustaining closed femoral shaft fractures ... tweak, and build upon the work non-commercially, as long as the author is ... was compressed, and proximal locking screws were then.

  18. Biomechanical comparison of double-row locking plates versus single- and double-row non-locking plates in a comminuted metacarpal fracture model.

    Science.gov (United States)

    Gajendran, Varun K; Szabo, Robert M; Myo, George K; Curtiss, Shane B

    2009-12-01

    Open or unstable metacarpal fractures frequently require open reduction and internal fixation. Locking plate technology has improved fixation of unstable fractures in certain settings. In this study, we hypothesized that there would be a difference in strength of fixation using double-row locking plates compared with single- and double-row non-locking plates in comminuted metacarpal fractures. We tested our hypothesis in a gap metacarpal fracture model simulating comminution using fourth-generation, biomechanical testing-grade composite sawbones. The metacarpals were divided into 6 groups of 15 bones each. Groups 1 and 4 were plated with a standard 6-hole, 2.3-mm plate in AO fashion. Groups 2 and 5 were plated with a 6-hole double-row 3-dimensional non-locking plate with bicortical screws aimed for convergence. Groups 3 and 6 were plated with a 6-hole double-row 3-dimensional locking plate with unicortical screws. The plated metacarpals were then tested to failure against cantilever apex dorsal bending (groups 1-3) and torsion (groups 4-6). The loads to failure in groups 1 to 3 were 198 +/- 18, 223 +/- 29, and 203 +/- 19 N, respectively. The torques to failure in groups 4 to 6 were 2,033 +/- 155, 3,190 +/- 235, and 3,161 +/- 268 N mm, respectively. Group 2 had the highest load to failure, whereas groups 5 and 6 shared the highest torques to failure (p row plates had equivalent bending and torsional stiffness, significantly higher than observed for the single-row non-locking plate. No other statistical differences were noted between groups. When subjected to the physiologically relevant forces of apex dorsal bending and torsion in a comminuted metacarpal fracture model, double-row 3-dimensional non-locking plates provided superior stability in bending and equivalent stability in torsion compared with double-row 3-dimensional locking plates, whereas single-row non-locking plates provided the least stability.

  19. Screw-released roller brake

    Science.gov (United States)

    Vranish, John M. (Inventor)

    1999-01-01

    A screw-released roller brake including an input drive assembly, an output drive assembly, a plurality of locking sprags, a mechanical tripper nut for unlocking the sprags, and a casing therefor. The sprags consist of three dimensional (3-D) sprag members having pairs of contact surface regions which engage respective pairs of contact surface regions included in angular grooves or slots formed in the casing and the output drive assembly. The sprags operate to lock the output drive assembly to the casing to prevent rotation thereof in an idle mode of operation. In a drive mode of operation, the tripper is either self actuated or motor driven and is translated linearly up and down against a spline and at the limit of its travel rotates the sprags which unlock while coupling the input drive assembly to the output drive assembly so as to impart a turning motion thereto in either a clockwise or counterclockwise direction.

  20. APPLICABILITY OF FS-ALL-METAL SELF-LOCK NUTS FOR RAILWAY ROLLING STOCK OF 1520 MM GAUGE

    Directory of Open Access Journals (Sweden)

    R. Кreis

    2016-10-01

    Full Text Available Purpose. One of key requirements for rolling stock of next generation is essential increase of warranty period or running between maintenance depots and in periods between programming repair works. This will lead to a reduction of costs to maintenance and repair during service life of rolling stock. In this regard, the industry aspires to use (during construction, repairs, modernization of rolling stock a modern screw joints in structures for fixing parts. These screw joints could provide a high reliability under the action of vibration load. FS-hexagon all-metal self-lock nuts of multiple use, Flaig + Hommel GmbH company meets these requirements. Therefore, there is the need to consider the results of tests to confirm the reliability of FS-nuts in the new environment. Methodology. Test complex of developed programs and methods was carried out on railway rolling stock for functional demonstration of screw joints with FS-nuts. These tests include: 1 proof test and locking moment test as specified in ISO 2320 under normal climatic conditions and after low temperatures impact; 2 running test for rolling stock, secured the most load condition and according to supervised operation of next generation cars on the railway. Findings. Results of the tests testify that FS-all-metal self-lock nuts meet the requirements of international standards and confirm the reliability of the next generation rolling stock during its operation on the railway of 1520 mm gauge. Namely, locking moment and tightening torque is maintained in screw joints both on spring-suspended and unspring parts of freight car bogies by the action of vibration load under multiple use of FS-nuts. Originality. The developed software and methods was improved by conducting additional tests after exposure of screw joints with FS-nuts to low temperatures, as well as by control operations for assessing the condition of screw joints with FS-nuts, in the conditions of controlled operation of rolling

  1. Multiaxial pedicle screw designs: static and dynamic mechanical testing.

    Science.gov (United States)

    Stanford, Ralph Edward; Loefler, Andreas Herman; Stanford, Philip Mark; Walsh, William R

    2004-02-15

    Randomized investigation of multiaxial pedicle screw mechanical properties. Measure static yield and ultimate strengths, yield stiffness, and fatigue resistance according to an established model. Compare these measured properties with expected loads in vivo. Multiaxial pedicle screws provide surgical versatility, but the complexity of their design may reduce their strength and fatigue resistance. There is no published data on the mechanical properties of such screws. Screws were assembled according to a vertebrectomy model for destructive mechanical testing. Groups of five assemblies were tested in static tension and compression and subject to three cyclical loads. Modes of failure, yield, and ultimate strength, yield stiffness, and cycles to failure were determined for six designs of screw. Static compression yield loads ranged from 217.1 to 388.0 N and yield stiffness from 23.7 to 38.0 N/mm. Cycles to failure ranged from 42 x 10(3) to 4,719 x 10(3) at 75% of static ultimate load. There were significant differences between designs in all modes of testing. Failure occurred at the multiaxial link in static and cyclical compression. Bending yield strengths just exceeded loads expected in vivo. Multiaxial designs had lower static bending yield strength than fixed screw designs. Five out of six multiaxial screw designs achieved one million cycles at 200 N in compression bending. "Ball-in-cup" multiaxial locking mechanisms were vulnerable to fatigue failure. Smooth surfaces and thicker material appeared to be protective against fatigue failure.

  2. Biomechanical evaluation of the locking titanium cable in the fixture of distal tibiofibular syndesmosis injury

    Directory of Open Access Journals (Sweden)

    Shu-zhi YAO

    2016-08-01

    Full Text Available Objective  The article aims at evaluating the biological properties of tibiofibular titanium cable fixation device in terms of both anti-separation and stress shielding by comparison to the interior fixation with lag screw based on experimental observation. Methods  Six corpse ankle specimens were first tested of pressure-separation and stress measurement, the data from which were compared to the normal group, and then a syndesmosis injury model was established. All the samples are randomly divided into 2 groups of 3 specimens each, which were treated with tibiofibula locked titanium cable and lag screw fixation respectively for syndesmosis injury. Then, the samples were tested for pressure-separation and stress measurement. The biomechanical properties as anti-separation ability and stress shielding were analyzed and compared between the two fixation method. Results  Both tibiofibula locked titanium cables and lag screws were able to provide enough strong lateral anti-separation ability, but strong fixation screws were inferior to tibiofibular titanium cable fixation device in fibular longitudinal stress transduction. Conclusion  Tibiofibular titanium cable fixation device not only provide sufficient lateral anti-separation, but also reduces the tibial and fibular longitudinal stress shielding, thus being superior to the traditional lag screw in biomechanical properties. DOI: 10.11855/j.issn.0577-7402.2016.07.09

  3. Shape Memory Alloy (SMA)-Based Launch Lock

    Science.gov (United States)

    Badescu, Mircea; Bao, Xiaoqi; Bar-Cohen, Yoseph

    2014-01-01

    Most NASA missions require the use of a launch lock for securing moving components during the launch or securing the payload before release. A launch lock is a device used to prevent unwanted motion and secure the controlled components. The current launch locks are based on pyrotechnic, electro mechanically or NiTi driven pin pullers and they are mostly one time use mechanisms that are usually bulky and involve a relatively high mass. Generally, the use of piezoelectric actuation provides high precession nanometer accuracy but it relies on friction to generate displacement. During launch, the generated vibrations can release the normal force between the actuator components allowing shaft's free motion which could result in damage to the actuated structures or instruments. This problem is common to other linear actuators that consist of a ball screw mechanism. The authors are exploring the development of a novel launch lock mechanism that is activated by a shape memory alloy (SMA) material ring, a rigid element and an SMA ring holding flexure. The proposed design and analytical model will be described and discussed in this paper.

  4. [Measurement of screw length through drilling technique in osteosynthesis of the proximal humerus fractures].

    Science.gov (United States)

    Avcı, Cem Coşkun; Gülabi, Deniz; Sağlam, Necdet; Kurtulmuş, Tuhan; Saka, Gürsel

    2013-01-01

    This study aims to investigate the efficacy of screw length measurement through drilling technique on the reduction of intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures. Between January 2008 and June 2012, 98 patients (34 males, 64 females; mean age 64.4 years; range 35 to 81 years) who underwent osteosynthesis using locking anatomical proximal humerus plates (PHILOS) in our clinic with the diagnosis of Neer type 2, 3 or 4 were included. Two different surgical techniques were used to measure proximal screw length in the plate and patients were divided into two groups based on the technique used. In group 1, screw length was determined by a 3 mm blunt tipped Kirschner wire without fluoroscopic control. In group 2, bilateral fluoroscopic images for each screw at least were obtained. Intraarticular screw penetration was detected in five patients (10.6%) in group 1, and in 19 patients (37.3%) in group 2. The mean fluoroscopic imaging time was 10.6 seconds in group 1 and 24.8 seconds in group 2, indicating a statistically significant difference. Screw length measurement through the drilling technique significantly reduces the intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures using PHILOS plates.

  5. A complete absorption mechanism of stacking fault tetrahedron by screw dislocation in copper

    International Nuclear Information System (INIS)

    Fan, Haidong; Wang, Qingyuan

    2013-01-01

    It was frequently observed in experiments that stacking fault tetrahedron (SFT) can be completely absorbed by dislocation and generate defect-free channels in irradiated materials, but the mechanism is still open. In this paper, molecular dynamics (MD) was used to explore the dislocation mechanism of reaction between SFT and screw dislocation in copper. Our computational results reveal that, at high temperature, the SFT is completely absorbed by screw dislocation with the help of Lomer–Cottrell (LC) lock transforming into Lomer dislocation. This complete absorption mechanism is very helpful to understand the defect-free channels in irradiated materials

  6. Impact of double-tiered subchondral support procedure with a polyaxial locking plate on the stability of distal radius fractures using fresh cadaveric forearms: Biomechanical and radiographic analyses.

    Science.gov (United States)

    Tsutsui, Sadaaki; Kawasaki, Keikichi; Yamakoshi, Ken-Ichi; Uchiyama, Eiichi; Aoki, Mitsuhiro; Inagaki, Katsunori

    2016-09-01

    The present study compared the changes in biomechanical and radiographic properties under cyclic axial loadings between the 'double-tiered subchondral support' (DSS) group (wherein two rows of screws were used) and the 'non-DSS' (NDSS) group (wherein only one row of distal screws was used) using cadaveric forearm models of radius fractures fixed with a polyaxial locking plate. Fifteen fresh cadaveric forearms were surgically operated to generate an Arbeitsgemeinschaft für Osteosynthesefragen (AO) type 23-C2 fracture model with the fixation of polyaxial volar locking plates. The model specimens were randomized into two groups: DSS (n = 7) and NDSS (n = 8). Both the groups received 4 locking screws in the most distal row, as is usually applied, whereas the DSS group received 2 additional screws in the second row inserted at an inclination of about 15° to support the dorsal aspect of the dorsal subchondral bone. Cyclic axial compression test was performed (3000 cycles; 0-250 N; 60 mm/min) to measure absolute rigidity and displacement, after 1, 1000, 2000 and 3000 cycles, and values were normalized relative to cycle 1. These absolute and normalized values were compared between those two groups. Radiographic images were taken before and after the cyclic loading to measure changes in volar tilt (ΔVT) and radial inclination (ΔRI). The DSS group maintained significantly higher rigidity and lower displacement values than the NDSS group during the entire loading period. Radiographic analysis indicated that the ΔVT values of the DSS group were lower than those of the NDSS group. In contrast, the fixation design did not influence the impact of loading on the ΔRI values. Biomechanical and radiographic analyses demonstrated that two rows of distal locking screws in the DSS procedure conferred higher stability than one row of distal locking screws. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  7. Is the lag screw sliding effective in the intramedullary nailing in A1 and A2 AO-OTA intertrochanteric fractures? A prospective study of Sliding and None-sliding lag screw in Gamma-III nail

    Directory of Open Access Journals (Sweden)

    Zhu Yi

    2012-09-01

    Full Text Available Abstract Object To compare the Sliding with Non-sliding lag screw of a gamma nail in the treatment of A1 and A2 AO-OTA intertrochanteric fractures. Materials and methods 80 patients were prospectively collected. In each group, AO/OTA 31-A were classified into group A. AO/OTA 31-A2.1 was classified as group B. We classified the A2.2 and A2.3 as group C. According to the set-screw locking formation of Gamma-III, the cases were randomly allocated to Sliding subgroup and Non-sliding subgroup in A, B and C groups. Follow-ups were performed 1, 3, 6 and 12 months postoperatively. Results In the Sliding group, the bone healing rate 3, 6, 12 months postoperatively reached 85.00%, 97.50%, 100% in group A, B and C. Meanwhile, in Non-sliding group, postoperatively, bone healing rate were 90.00%, 95.00% and 97.50% in group A, B and C, respectively. Both differences were not significant. Lower limb discrepancy between Sliding and Non-sliding pattern was significantly different in group C which represent fracture types of AO/OTA 31-A2.2 and A2.3 (0.573 ± 0.019 mm in Non-sliding group, 0.955 mm ± 0.024 mm in Sliding group, P Conclusions As a result, we can conclude that the sliding distance is minimal in Gamma nails and it is related to the comminuted extent of the intertrochanteric area in A1 and A2 AO-OTA intertrochanteric fractures. For treating these kinds of fractures, the sliding of the lag screw of an Gamma nail does not improve any clinical results and in certain cases, such as highly comminuted A1 and A2 fractures, can therefore even benefit from a locked lag screw by tightening the set-screw.

  8. Universal spin-momentum locked optical forces

    Energy Technology Data Exchange (ETDEWEB)

    Kalhor, Farid [Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta T6G 1H9 (Canada); Thundat, Thomas [Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 1H9 (Canada); Jacob, Zubin, E-mail: zjacob@purdue.edu [Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Alberta T6G 1H9 (Canada); Birck Nanotechnology Center, Department of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47906 (United States)

    2016-02-08

    Evanescent electromagnetic waves possess spin-momentum locking, where the direction of propagation (momentum) is locked to the inherent polarization of the wave (transverse spin). We study the optical forces arising from this universal phenomenon and show that the fundamental origin of recently reported non-trivial optical chiral forces is spin-momentum locking. For evanescent waves, we show that the direction of energy flow, the direction of decay, and the direction of spin follow a right hand rule for three different cases of total internal reflection, surface plasmon polaritons, and HE{sub 11} mode of an optical fiber. Furthermore, we explain how the recently reported phenomena of lateral optical force on chiral and achiral particles are caused by the transverse spin of the evanescent field and the spin-momentum locking phenomenon. Finally, we propose an experiment to identify the unique lateral forces arising from the transverse spin in the optical fiber and point to fundamental differences of the spin density from the well-known orbital angular momentum of light. Our work presents a unified view on spin-momentum locking and how it affects optical forces on chiral and achiral particles.

  9. Dual small fragment plating improves screw-to-screw load sharing for mid-diaphyseal humeral fracture fixation: a finite element study.

    Science.gov (United States)

    Kosmopoulos, Victor; Luedke, Colten; Nana, Arvind D

    2015-01-01

    A smaller humerus in some patients makes the use of a large fragment fixation plate difficult. Dual small fragment plate constructs have been suggested as an alternative. This study compares the biomechanical performance of three single and one dual plate construct for mid-diaphyseal humeral fracture fixation. Five humeral shaft finite element models (1 intact and 4 fixation) were loaded in torsion, compression, posterior-anterior (PA) bending, and lateral-medial (LM) bending. A comminuted fracture was simulated by a 1-cm gap. Fracture fixation was modelled by: (A) 4.5-mm 9-hole large fragment plate (wide), (B) 4.5-mm 9-hole large fragment plate (narrow), (C) 3.5-mm 9-hole small fragment plate, and (D) one 3.5-mm 9-hole small fragment plate and one 3.5-mm 7-hole small fragment plate. Model A showed the best outcomes in torsion and PA bending, whereas Model D outperformed the others in compression and LM bending. Stress concentrations were located near and around the unused screw holes for each of the single plate models and at the neck of the screws just below the plates for all the models studied. Other than in PA bending, Model D showed the best overall screw-to-screw load sharing characteristics. The results support using a dual small fragment locking plate construct as an alternative in cases where crutch weight-bearing (compression) tolerance may be important and where anatomy limits the size of the humerus bone segment available for large fragment plate fixation.

  10. Removal torque of nail interlocking screws is related to screw proximity to the fracture and screw breakage.

    Science.gov (United States)

    White, Alexander A; Kubacki, Meghan R; Samona, Jason; Telehowski, Paul; Atkinson, Patrick J

    2016-06-01

    Studies have shown that titanium implants can be challenging to explant due to the material's excellent biocompatibility and resulting osseointegration. Clinically, titanium alloy nail interlocking screws may require removal to dynamize a construct or revise the nail due to nonunion, infection, pain, or periprosthetic fracture. This study was designed to determine what variables influence the removal torque for titanium alloy interlocking screws. An intramedullary nail with four interlocking screws was used to stabilize a 1-cm segmental femoral defect in a canine model for 16 weeks. The animals were observed to be active following a several-day recovery after surgery. In six animals, the femora and implanted nail/screws were first tested to failure in torsion to simulate periprosthetic fracture of an implant after which the screws were then removed. In four additional animals, the screws were removed without mechanical testing. Both intraoperative insertional and extraction torques were recorded for all screws. Mechanical testing to failure broke 10/24 screws. On average, the intact screws required 70% of the insertional torque during removal while broken screws only required 16% of the insertional torque (p torque than the outboard distal screw (p torque was ∼80°. The peak axial load did not significantly correlate with the torque required to remove the screws. On average, the removal torque was lower than at the time of insertion, and less torque was required to remove broken screws and screws remote to the fracture. However, broken screws will require additional time to retrieve the remaining screw fragment. This study suggests that broken screws and screws in prematurely active patients will require less torque to remove. © IMechE 2016.

  11. An implementation of the flexible spin-lock model in ERIKA Enterprise on a multi-core platform

    NARCIS (Netherlands)

    Afshar, S.; Verwielen, M.P.W.; Gai, P.; Behnam, M.; Bril, R.J.

    2016-01-01

    Recently, the flexible spin-lock model (FSLM) has been introduced, unifying spin-based and suspension-based resource sharing protocols for real-time multiprocessor platforms by explicitly identifying the spin-lock priority as a parameter. Earlier work focused on the definition of a protocol for FSLM

  12. Ball Screw Actuator Including a Compliant Ball Screw Stop

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Hanlon, Casey (Inventor)

    2017-01-01

    An actuator includes a ball nut, a ball screw, and a ball screw stop. The ball nut is adapted to receive an input torque and in response rotates and supplies a drive force. The ball screw extends through the ball nut and has a first end and a second end. The ball screw receives the drive force from the ball nut and in response selectively translates between a retract position and a extend position. The ball screw stop is mounted on the ball screw proximate the first end to translate therewith. The ball screw stop engages the ball nut when the ball screw is in the extend position, translates, with compliance, a predetermined distance toward the first end upon engaging the ball nut, and prevents further rotation of the ball screw upon translating the predetermined distance.

  13. Clinical effects of posterior pedicle screw fixation on spinal deformity in growing period: a report of 360 cases

    Directory of Open Access Journals (Sweden)

    Zheng-lei WANG

    2011-08-01

    Full Text Available Objective To observe the effect of a new kind of pedicle screw frame system with sliding terminus and locked middle segment on spinal deformity in growing period.Methods Three hundred and sixty patients in growing period were involved in the present study,and among them 82 were suffering from congenital scoliosis,218 idiopathic scoliosis and 60 kyphosis.All the patients were treated with the pedicle screw frame system with sliding terminus and locked middle segment.The treatment effects and postoperative complications were observed,and the Cobb angle before and after the operation was compared.Results The Cobb angle of 300 scoliosis patients was corrected from 53°±3° to 8°±2°,and the Cobb angle of 60 kyphosis patients was corrected from 60°±2° to 25°±3°,and the corrective effect was satisfactory.The correction rate of patients with Cobb angle ≤50° was 80%.Two hundred and ten patients were followed-up for 1 to 6 years,and the longitudinal growth of spine was 1.5-4.0cm.No severe complication,such as screw fracture,rod fracture or nerve injury,occurred.Conclusion The pedicle screw frame system with sliding terminus had a favorable three-dimensional correction effect,and the spine growth would not be restricted,and there was no stiffness,vertebral rotation,or distortion of shaft after operation.

  14. Ex vivo biomechanical evaluation of pigeon (Columba livia) cadaver intact humeri and ostectomized humeri stabilized with caudally applied titanium locking plate or stainless steel nonlocking plate constructs.

    Science.gov (United States)

    Darrow, Brett G; Biskup, Jeffrey J; Weigel, Joseph P; Jones, Michael P; Xie, Xie; Liaw, Peter K; Tharpe, Josh L; Sharma, Aashish; Penumadu, Dayakar

    2017-05-01

    OBJECTIVE To evaluate mechanical properties of pigeon (Columba livia) cadaver intact humeri versus ostectomized humeri stabilized with a locking or nonlocking plate. SAMPLE 30 humeri from pigeon cadavers. PROCEDURES Specimens were allocated into 3 groups and tested in bending and torsion. Results for intact pigeon humeri were compared with results for ostectomized humeri repaired with a titanium 1.6-mm screw locking plate or a stainless steel 1.5-mm dynamic compression plate; the ostectomized humeri mimicked a fracture in a thin cortical bone. Locking plates were secured with locking screws (2 bicortical and 4 monocortical), and nonlocking plates were secured with bicortical nonlocking screws. Constructs were cyclically tested nondestructively in 4-point bending and then tested to failure in bending. A second set of constructs were cyclically tested non-destructively and then to failure in torsion. Stiffness, strength, and strain energy of each construct were compared. RESULTS Intact specimens were stiffer and stronger than the repair groups for all testing methods, except for nonlocking constructs, which were significantly stiffer than intact specimens under cyclic bending. Intact bones had significantly higher strain energies than locking plates in both bending and torsion. Locking and nonlocking plates were of equal strength and strain energy, but not stiffness, in bending and were of equal strength, stiffness, and strain energy in torsion. CONCLUSIONS AND CLINICAL RELEVANCE Results for this study suggested that increased torsional strength may be needed before bone plate repair can be considered as the sole fixation method for avian species.

  15. Comparison of the Mechanical Characteristics of a Universal Small Biplane Plating Technique Without Compression Screw and Single Anatomic Plate With Compression Screw.

    Science.gov (United States)

    Dayton, Paul; Ferguson, Joe; Hatch, Daniel; Santrock, Robert; Scanlan, Sean; Smith, Bret

    2016-01-01

    To better understand the mechanical characteristics of biplane locked plating in small bone fixation, the present study compared the stability under cyclic cantilever loading of a 2-plate locked biplane (BPP) construct without interfragmentary compression with that of a single-plate locked construct with an additional interfragmentary screw (SPS) using surrogate bone models simulating Lapidus arthrodesis. In static ultimate plantar bending, the BPP construct failed at significantly greater load than did the SPS construct (556.2 ± 37.1 N versus 241.6 ± 6.3 N, p = .007). For cyclic failure testing in plantar bending at a 180-N starting load, the BPP construct failed at a significantly greater number of cycles (158,322 ± 50,609 versus 13,718 ± 10,471 cycles) and failure load (242.5 ± 25.0 N versus 180.0 ± 0.0 N) than the SPS construct (p = .002). For cyclic failure testing in plantar bending at a 120-N starting load, the results were not significantly different between the BPP and SPS constructs for the number of cycles (207,646 ± 45,253 versus 159,334 ± 69,430) or failure load (205.0 ± 22.4 N versus 185.0 ± 33.5 N; p = .300). For cyclic testing with 90° offset loading (i.e., medial to lateral bending) at a 120-N starting load, all 5 BPP constructs (tension side) and 2 of the 5 SPS constructs reached 250,000 cycles without failure. Overall, the present study found the BPP construct to have superior or equivalent stability in multiplanar orientations of force application in both static and fatigue testing. Thus, the concept of biplane locked plating, using 2 low profile plates and unicortical screw insertion, shows promise in small bone fixation, because it provides consistent stability in multiplanar orientations, making it universally adaptable to many clinical situations. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Design of Cold-Formed Steel Screw Connections with Gypsum Sheathing at Ambient and Elevated Temperatures

    Directory of Open Access Journals (Sweden)

    Wei Chen

    2016-09-01

    Full Text Available Load-bearing cold-formed steel (CFS walls sheathed with double layers of gypsum plasterboard on both sides have demonstrated good fire resistance and attracted increasing interest for use in mid-rise CFS structures. As the main connection method, screw connections between CFS and gypsum sheathing play an important role in both the structural design and fire resistance of this wall system. However, studies on the mechanical behavior of screw connections with double-layer gypsum sheathing are still limited. In this study, 200 monotonic tests of screw connections with single- or double-layer gypsum sheathing at both ambient and elevated temperatures were conducted. The failure of screw connections with double-layer gypsum sheathing in shear was different from that of single-layer gypsum sheathing connections at ambient temperature, and it could be described as the breaking of the loaded sheathing edge combined with significant screw tilting and the loaded sheathing edge flexing fracture. However, the screw tilting and flexing fracture of the loaded sheathing edge gradually disappear at elevated temperatures. In addition, the influence of the loaded edge distance, double-layer sheathing and elevated temperatures is discussed in detail with clear conclusions. A unified design formula for the shear strength of screw connections with gypsum sheathing is proposed for ambient and elevated temperatures with adequate accuracy. A simplified load–displacement model with the post-peak branch is developed to evaluate the load–displacement response of screw connections with gypsum sheathing at ambient and elevated temperatures.

  17. Simple New Screw Insertion Technique without Extraction for Broken Pedicle Screws.

    Science.gov (United States)

    Kil, Jin-Sang; Park, Jong-Tae

    2018-05-01

    Spinal transpedicular screw fixation is widely performed. Broken pedicle screw rates range from 3%-7.1%. Several techniques have been described for extraction of broken pedicle screws. However, most of these techniques require special instruments. We describe a simple, modified technique for management of broken pedicle screws without extraction. No special instruments or drilling in an adjacent pedicle are required. We used a high-speed air drill with a round burr. With C-arm fluoroscopy guidance, the distal fragment of a broken pedicle screw was palpated using free-hand technique through the screw entry hole. A high-speed air drill with a round burr (not a diamond burr) was inserted through the hole. Drilling began slowly and continued until enough space was obtained for new screw insertion. Using this space, we performed new pedicle screw fixation medially alongside the distal fragment of the broken pedicle screw. We performed the insertion with a previously used entry hole and pathway in the pedicle. The same size pedicle screw was used. Three patients were treated with this modified technique. New screw insertion was successful in all cases after partial drilling of the distal broken pedicle screw fragment. There were no complications, such as screw loosening, dural tears, or root injury. We describe a simple, modified technique for management of broken pedicle screws without extraction. This technique is recommended in patients who require insertion of a new screw. Copyright © 2017. Published by Elsevier Inc.

  18. APR1400 Locked Rotor Transient Analysis using KNAP

    International Nuclear Information System (INIS)

    Lee, Dong-Hyuk; Kim, Yo-Han; Ha, Sang Jun

    2007-01-01

    KEPRI (Korea Electric Power Research Institute) has developed safety analysis methodology for non-LOCA (Loss Of Coolant Accident) analysis of OPR1000 (Optimized Power Reactor 1000, formerly KSNP). The new methodology, named KNAP (Korea Non-LOCA Analysis Package), uses RETRAN as the main system analysis code for most transients. For locked rotor transient DNBR analysis, UNICORN-TM code is used. UNICORN-TM is the unified code of RETRAN, MASTER and TORC. The UNICORN-TM has 1-D and 3-D neutron kinetics calculation capability. For locked rotor DNBR analysis, 1-D neutron kinetics is used. In this paper, we apply KNAP methodology to APR1400 (Advanced Power Reactor 1400) locked rotor analysis and compare the results with those in the APR1400 SSAR(Standard Safety Analysis Report). The locked rotor transient is one of the 'decrease in reactor coolant system flow rate' events and the results are typically described in the chapter 15.3.3 of SAR (Safety Analysis Report). In this study, to confirm the applicability of the KNAP methodology and code system to APR1400, locked rotor transient is analyzed using UNICORN-TM code and the results are compared with those from APR1400 SSAR

  19. APR1400 Locked Rotor Transient Analysis using KNAP

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong-Hyuk; Kim, Yo-Han; Ha, Sang Jun [Korea Electric Power Research Institute, Daejeon (Korea, Republic of)

    2007-07-01

    KEPRI (Korea Electric Power Research Institute) has developed safety analysis methodology for non-LOCA (Loss Of Coolant Accident) analysis of OPR1000 (Optimized Power Reactor 1000, formerly KSNP). The new methodology, named KNAP (Korea Non-LOCA Analysis Package), uses RETRAN as the main system analysis code for most transients. For locked rotor transient DNBR analysis, UNICORN-TM code is used. UNICORN-TM is the unified code of RETRAN, MASTER and TORC. The UNICORN-TM has 1-D and 3-D neutron kinetics calculation capability. For locked rotor DNBR analysis, 1-D neutron kinetics is used. In this paper, we apply KNAP methodology to APR1400 (Advanced Power Reactor 1400) locked rotor analysis and compare the results with those in the APR1400 SSAR(Standard Safety Analysis Report). The locked rotor transient is one of the 'decrease in reactor coolant system flow rate' events and the results are typically described in the chapter 15.3.3 of SAR (Safety Analysis Report). In this study, to confirm the applicability of the KNAP methodology and code system to APR1400, locked rotor transient is analyzed using UNICORN-TM code and the results are compared with those from APR1400 SSAR.

  20. Pedicle screw anchorage of carbon fiber-reinforced PEEK screws under cyclic loading.

    Science.gov (United States)

    Lindtner, Richard A; Schmid, Rene; Nydegger, Thomas; Konschake, Marko; Schmoelz, Werner

    2018-03-01

    Pedicle screw loosening is a common and significant complication after posterior spinal instrumentation, particularly in osteoporosis. Radiolucent carbon fiber-reinforced polyetheretherketone (CF/PEEK) pedicle screws have been developed recently to overcome drawbacks of conventional metallic screws, such as metal-induced imaging artifacts and interference with postoperative radiotherapy. Beyond radiolucency, CF/PEEK may also be advantageous over standard titanium in terms of pedicle screw loosening due to its unique material properties. However, screw anchorage and loosening of CF/PEEK pedicle screws have not been evaluated yet. The aim of this biomechanical study therefore was to evaluate whether the use of this alternative nonmetallic pedicle screw material affects screw loosening. The hypotheses tested were that (1) nonmetallic CF/PEEK pedicle screws resist an equal or higher number of load cycles until loosening than standard titanium screws and that (2) PMMA cement augmentation further increases the number of load cycles until loosening of CF/PEEK screws. In the first part of the study, left and right pedicles of ten cadaveric lumbar vertebrae (BMD 70.8 mg/cm 3  ± 14.5) were randomly instrumented with either CF/PEEK or standard titanium pedicle screws. In the second part, left and right pedicles of ten vertebrae (BMD 56.3 mg/cm 3  ± 15.8) were randomly instrumented with either PMMA-augmented or nonaugmented CF/PEEK pedicle screws. Each pedicle screw was subjected to cyclic cranio-caudal loading (initial load ranging from - 50 N to + 50 N) with stepwise increasing compressive loads (5 N every 100 cycles) until loosening or a maximum of 10,000 cycles. Angular screw motion ("screw toggling") within the vertebra was measured with a 3D motion analysis system every 100 cycles and by stress fluoroscopy every 500 cycles. The nonmetallic CF/PEEK pedicle screws resisted a similar number of load cycles until loosening as the contralateral standard

  1. Incorporating implementation overheads in the analysis for the flexible spin-lock model

    NARCIS (Netherlands)

    Balasubramanian, S.M.N.; Afshar, S.; Gai, P.; Behnam, M.; Bril, R.J.

    2017-01-01

    The flexible spin-lock model (FSLM) unifies suspension-based and spin-based resource sharing protocols for partitioned fixed-priority preemptive scheduling based real-time multiprocessor platforms. Recent work has been done in defining the protocol for FSLM and providing a schedulability analysis

  2. Intramedullary fixation of proximal humerus fractures: do locking bolts endanger the axillary nerve or the ascending branch of the anterior circumflex artery? A cadaveric study

    Directory of Open Access Journals (Sweden)

    Sermon An

    2008-12-01

    Full Text Available Abstract Background Proximal humerus fractures are one of the most common fractures. Intramedullary locked nailing is becoming a popular alternative treatment, especially for easier fracture patterns. Although axillary nerve injury has been reported, no study has compared the safety of the proximal locking options relative to the axillary nerve and the ascending branch of the anterior circumflex artery. Method Six different commercially available proximal humeral nails were implanted in 30 shoulders of 18 cadavers. After fluoroscopically guided implantation the shoulders were carefully dissected and the distance between the locking screws, the axillary nerve and the ascending branch of the anterior circumflex artery was measured. Results The course of the axillary nerve varies. A mean distance of 55.8 mm (SD = 5.3 between the lateral edge of the acromions and the axillary nerve at the middle of the humerus in a neutrally rotated position was observed. The minimum distance was 43.4 mm, the maximum 63.9 mm. Bent nails with oblique head interlocking bolts appeared to be the most dangerous in relation to the axillary nerve. The two designs featuring such a bend and oblique bolt showed a mean distance of the locking screw to the axillary nerve of 1 mm and 2.7 mm respectively Sirus (Zimmer® and (Stryker® T2 PHN (Proximal Humeral Nail. Regarding the ascending branch of the anterior circumflex artery, there was no difference between the nails which have an anteroposterior locking option. Conclusion It is of great importance for surgeons treating proximal humerus fractures to understand the relative risk of any procedure they perform. Since the designs of different nailing systems risk damaging the axillary nerve and ascending branch, blunt dissection, the use of protection sleeves during drilling and screw insertion, and individual risk evaluation prior to the use of a proximal humeral nail are advocated.

  3. An Analytical Model for Rotation Stiffness and Deformation of an Antiloosening Nut under Locking Force

    Directory of Open Access Journals (Sweden)

    X. J. Jiang

    2014-01-01

    Full Text Available Screw fasteners are undoubtedly one of the most important machine elements due to their outstanding characteristic to provide a high clamping force just with a simplified design. However, the loosen vibration is their inherent and inevitable fault. The friction locking approach is one of the basic locking fastener categories by enhancing the bearing load on the contact surface of thread by applying a locking force on an antiloosening nut. This locking force may cause more severe deformation in the nut. The contact stress distribution on the nut would be changed and that can cause the variation of the friction torque for the bolt joint. However, there exists no established design calculation procedure that accounts for the rotation deformation and its stiffness of the antiloosening nut under the locking force. The main objective of the work is to develop an analytical solution to the rotation deformation problem encountered in the antiloosening nut. The proposed model is supported by comparison with numerical finite element analysis of different sizes of joint elements and different applied forces.

  4. Comparative endurance testing of the Biomet Matthews Nail and the Dynamic Compression Screw, in simulated condylar and supracondylar femoral fractures

    Directory of Open Access Journals (Sweden)

    Davies Benjamin M

    2008-01-01

    Full Text Available Abstract Background The dynamic compression screw is a plate and screws implant used to treat fractures of the distal femur. The Biomet Matthews Nail is a new retrograde intramedullary nail designed as an alternative surgical option to treat these fractures. The objective of this study was to assess the comparative endurance of both devices. Method The dynamic compression screw (DCS and Biomet Matthews Nail (BMN were implanted into composite femurs, which were subsequently cyclically loaded using a materials testing machine. Simulated fractures were applied to each femur prior to the application of load. Either a Y type fracture or a transverse osteotomy was prepared on each composite femur using a jig to enable consistent positioning of cuts. Results The Biomet Matthews Nail demonstrated a greater endurance limit load over the dynamic compression screw in both fracture configurations. Conclusion The distal locking screws pass through the Biomet Matthews Nail in a unique "cruciate" orientation. This allows for greater purchase in the bone of the femoral condyle and potentially improves the stability of the fracture fixation. As these fractures are usually in weak osteoporotic bone, the Biomet Matthews Nail represents a favourable surgical option in these patients.

  5. Noise-shaping all-digital phase-locked loops modeling, simulation, analysis and design

    CERN Document Server

    Brandonisio, Francesco

    2014-01-01

    This book presents a novel approach to the analysis and design of all-digital phase-locked loops (ADPLLs), technology widely used in wireless communication devices. The authors provide an overview of ADPLL architectures, time-to-digital converters (TDCs) and noise shaping. Realistic examples illustrate how to analyze and simulate phase noise in the presence of sigma-delta modulation and time-to-digital conversion. Readers will gain a deep understanding of ADPLLs and the central role played by noise-shaping. A range of ADPLL and TDC architectures are presented in unified manner. Analytical and simulation tools are discussed in detail. Matlab code is included that can be reused to design, simulate and analyze the ADPLL architectures that are presented in the book.   • Discusses in detail a wide range of all-digital phase-locked loops architectures; • Presents a unified framework in which to model time-to-digital converters for ADPLLs; • Explains a procedure to predict and simulate phase noise in oscil...

  6. Effects of Screw Configuration on the Preload Force of Implant-Abutment Screws.

    Science.gov (United States)

    Zipprich, Holger; Rathe, Florian; Pinz, Sören; Schlotmann, Luca; Lauer, Hans-Christoph; Ratka, Christoph

    The aim of this study was to investigate the effects of tightening torque, screw head angle, and thread number on the preload force of abutment screws. The test specimens consisted of three self-manufactured components (ie, a thread sleeve serving as an implant analog, an abutment analog, and an abutment screw). The abutment screws were fabricated with metric M1.6 external threads. The thread number varied between one and seven threads. The screw head angles were produced in eight varying angles (30 to 180 degrees). A sensor unit simultaneously measured the preload force of the screw and the torsion moment inside the screw shank. The tightening of the screw with the torque wrench was performed in five steps (15 to 35 Ncm). The torque wrench was calibrated before each step. Only the tightening torque and screw head angle affected the resulting preload force of the implant-abutment connection. The thread number had no effect. There was an approximately linear correlation between tightening torque and preload force. The tightening torque and screw head angle were the only study parameters that affected the resulting preload force of the abutment screw. The results obtained from this experiment are valid only for a single torque condition. Further investigations are needed that analyze other parameters that affect preload force. Once these parameters are known, it will add value for a strong, but detachable connection between the implant and abutment. Short implants and flat-to-flat connections especially will benefit significantly from this knowledge.

  7. Positioning device for screwing or unscrewing screw nut

    International Nuclear Information System (INIS)

    Sevelinge, G.

    1987-01-01

    This automatic positioning device for screwing or unscrewing a screw nut on a closure stud has a drawed socket and means for axially centre and angularly by wedge the socket on the closure stud and generate a continuous spiral between the socket and the closure stud [fr

  8. Rotationally Stable Screw-Anchor With Locked Trochanteric Stabilizing Plate Versus Proximal Femoral Nail Antirotation in the Treatment of AO/OTA 31A2.2 Fracture: A Biomechanical Evaluation.

    Science.gov (United States)

    Knobe, Matthias; Nagel, Philipp; Maier, Klaus-Jürgen; Gradl, Gertraud; Buecking, Benjamin; Sönmez, Tolga T; Modabber, Ali; Prescher, Andreas; Pape, Hans-Christoph

    2016-01-01

    Third-generation cephalomedullary nails currently represent the gold standard in the treatment of unstable trochanteric femur fractures. Recently, an extramedullary rotationally stable screw-anchor system (RoSA) has been developed. It was designed to combine the benefits of screw and blade and to improve stability using a locked trochanteric stabilizing plate (TSP). The purpose of this study was to compare the biomechanical behavior of RoSA/TSP and the proximal femoral nail antirotation (PFNA). Standardized AO/OTA 31A2.2 fractures were induced by an oscillating saw in 10 paired human specimens (n = 20; mean age = 85 years; range: 71-96 years). The fractures were stabilized by either the RoSA/TSP (Koenigsee Implants, Allendorf, Germany) or the PFNA (DePuy Synthes, Zuchwil, Switzerland). Femurs were positioned in 25 degrees of adduction and 10 degrees of posterior flexion and were cyclically loaded with axial sinusoidal pattern at 0.5 Hz, starting at 300 N, with stepwise increase by 300 N every 500 cycles until bone-implant failure occurred. After every load step, the samples were measured visually and radiographically. Femoral head migration was assessed. The stiffness at the load up to the clinically relevant load step of 1800 N (639 ± 378 N/mm (RoSA/TSP) vs. 673 ± 227 N/mm (PFNA); P = 0.542) was comparable, as was the failure load (3000 ± 787 N vs. 3780 ± 874 N; P = 0.059). Up to 1800 N, no femoral head rotation, head migration, or femoral neck shortening were observed either for RoSA/TSP or PFNA. Whereas failure of the PFNA subsumed fractures of the greater trochanter and the lateral wall, a posterior femoral neck fracture with a significantly increased femoral neck shortening (1.7 mm vs. 0 mm; P = 0.012) was the cause of failure with RoSA/TSP. This specific kind of failure was induced by a femoral neck weakening caused by the posterior TSP stabilizing screw. There was no significant difference in biomechanical properties between the RoSA/TSP and the PFNA for

  9. Biomechanics of lumbar cortical screw-rod fixation versus pedicle screw-rod fixation with and without interbody support.

    Science.gov (United States)

    Perez-Orribo, Luis; Kalb, Samuel; Reyes, Phillip M; Chang, Steve W; Crawford, Neil R

    2013-04-15

    Seven different combinations of posterior screw fixation, with or without interbody support, were compared in vitro using nondestructive flexibility tests. To study the biomechanical behavior of a new cortical screw (CS) fixation construct relative to the traditional pedicle screw (PS) construct. The CS is an alternative to the PS for posterior fixation of the lumbar spine. The CS trajectory is more sagittally and cranially oriented than the PS, being anchored in the pars interarticularis. Like PS fixation, CS fixation uses interconnecting rods fastened with top-locking connectors. Stability after bilateral CS fixation was compared with stability after bilateral PS fixation in the setting of intact disc and with direct lateral interbody fixation (DLIF) or transforaminal lateral interbody fixation (TLIF) support. Standard nondestructive flexibility tests were performed in cadaveric lumbar specimens, allowing non-paired comparisons of specific conditions from 28 specimens (4 groups of 7) within a larger experiment of multiple hardware configurations. Condition tested and group from which results originated were as follows: (1) intact (all groups); (2) with L3-L4 bilateral PS-rods (group 1); (3) with bilateral CS-rods (group 2); (4) with DLIF (group 3); (5) with DLIF + CS-rods (group 4); (6) with DLIF + PS-rods (group 3); (7) with TLIF + CS-rods (group 2), and (8) with TLIF + PS-rods (group 2). To assess spinal stability, the mean range of motion, lax zone, and stiff zone at L3-L4 were compared during flexion-extension, lateral bending, and axial rotation. With intact disc, stability was equivalent after PS-rod and CS-rod fixation, except that PS-rod fixation was stiffer during axial rotation. With DLIF support, there was no significant difference in stability between PS-rod and CS-rod fixation. With TLIF support, PS-rod fixation was stiffer than CS-rod fixation during lateral bending. Bilateral CS-rod fixation provided about the same stability in cadaveric specimens

  10. Broken Bioabsorbable Tibial Interference Screw after Anterior Cruciate Ligament (ACL Reconstruction using a Semitendinosus-gracilis Graft: A Case Report

    Directory of Open Access Journals (Sweden)

    Huang ME Deborah

    2012-07-01

    Full Text Available When a patient presents with knee pain and locking after an anterior cruciate ligament (ACL reconstruction, a new meniscal injury or an osteochondral loose body are usually considered for differential diagnosis. We present the case of a 22-year-old female with just these complaints 6 months after ACL reconstruction surgery. Magnetic resonance imaging (MRI of the knee showed a broken screw tip which was later arthroscopically removed. At arthroscopy, an 11mm long broken bioabsorbable interference screw tip was found lying in the intercondylar notch; this resulted in a 0.5cm Outerbridge grade II chondral ulcer located at mid- patella. Both menisci and cruciate ligaments were intact and no other loose bodies were found in the knee joint.

  11. Tapping insertional torque allows prediction for better pedicle screw fixation and optimal screw size selection.

    Science.gov (United States)

    Helgeson, Melvin D; Kang, Daniel G; Lehman, Ronald A; Dmitriev, Anton E; Luhmann, Scott J

    2013-08-01

    There is currently no reliable technique for intraoperative assessment of pedicle screw fixation strength and optimal screw size. Several studies have evaluated pedicle screw insertional torque (IT) and its direct correlation with pullout strength. However, there is limited clinical application with pedicle screw IT as it must be measured during screw placement and rarely causes the spine surgeon to change screw size. To date, no study has evaluated tapping IT, which precedes screw insertion, and its ability to predict pedicle screw pullout strength. The objective of this study was to investigate tapping IT and its ability to predict pedicle screw pullout strength and optimal screw size. In vitro human cadaveric biomechanical analysis. Twenty fresh-frozen human cadaveric thoracic vertebral levels were prepared and dual-energy radiographic absorptiometry scanned for bone mineral density (BMD). All specimens were osteoporotic with a mean BMD of 0.60 ± 0.07 g/cm(2). Five specimens (n=10) were used to perform a pilot study, as there were no previously established values for optimal tapping IT. Each pedicle during the pilot study was measured using a digital caliper as well as computed tomography measurements, and the optimal screw size was determined to be equal to or the first size smaller than the pedicle diameter. The optimal tap size was then selected as the tap diameter 1 mm smaller than the optimal screw size. During optimal tap size insertion, all peak tapping IT values were found to be between 2 in-lbs and 3 in-lbs. Therefore, the threshold tapping IT value for optimal pedicle screw and tap size was determined to be 2.5 in-lbs, and a comparison tapping IT value of 1.5 in-lbs was selected. Next, 15 test specimens (n=30) were measured with digital calipers, probed, tapped, and instrumented using a paired comparison between the two threshold tapping IT values (Group 1: 1.5 in-lbs; Group 2: 2.5 in-lbs), randomly assigned to the left or right pedicle on each

  12. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System.

    Science.gov (United States)

    Sim, Bo Kyun; Kim, Bongju; Kim, Min Jeong; Jeong, Guk Hyun; Ju, Kyung Won; Shin, Yoo Jin; Kim, Man Yong; Lee, Jong-Ho

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA) and mechanical test. In the FEA results, both types of abutment screws showed similar stress distribution in the single artificial tooth system. A maximum load difference of about 2% occurred in the vertical load by a mechanical test. This study showed that the hollow abutment screw may be an alternative to the conventional abutment screws because this is designed for easy retrieval and that both abutment screws showed no significant difference in the mechanical tests and in the FEA.

  13. [Fracture of implant abutment screws and removal of a remaining screw piece

    NARCIS (Netherlands)

    Broeke, S.M. van den; Baat, C. de

    2008-01-01

    Fracture of the implant abutment screws is a complication which can render an implant useless. The prevalence of abutment screw fracture does not exceed 2.5% after 10 years. Causes are loosening of implant abutment screw, too few, too short or too narrow implants, implants not inserted perpendicular

  14. Effect of Repeated Screw Joint Closing and Opening Cycles and Cyclic Loading on Abutment Screw Removal Torque and Screw Thread Morphology: Scanning Electron Microscopy Evaluation.

    Science.gov (United States)

    Arshad, Mahnaz; Mahgoli, Hosseinali; Payaminia, Leila

    To evaluate the effect of repeated screw joint closing and opening cycles and cyclic loading on abutment screw removal torque and screw thread morphology using scanning electron microscopy (SEM). Three groups (n = 10 in each group) of implant-abutment-abutment screw assemblies were created. There were also 10 extra abutment screws as new screws in group 3. The abutment screws were tightened to 12 Ncm with an electronic torque meter; then they were removed and removal torque values were recorded. This sequence was repeated 5 times for group 1 and 15 times for groups 2 and 3. The same screws in groups 1 and 2 and the new screws in group 3 were then tightened to 12 Ncm; this was also followed by screw tightening to 30 Ncm and retightening to 30 Ncm 15 minutes later. Removal torque measurements were performed after screws were subjected to cyclic loading (0.5 × 10⁶ cycles; 1 Hz; 75 N). Moreover, the surface topography of one screw from each group before and after cyclic loading was evaluated with SEM and compared with an unused screw. All groups exhibited reduced removal torque values in comparison to insertion torque in each cycle. However, there was a steady trend of torque loss in each group. A comparison of the last cycle of the groups before loading showed significantly greater torque loss value in the 15th cycle of groups 2 and 3 compared with the fifth cycle of group 1 (P abutment is definitively placed.

  15. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

    Directory of Open Access Journals (Sweden)

    Bo Kyun Sim

    2017-01-01

    Full Text Available The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA and mechanical test. In the FEA results, both types of abutment screws showed similar stress distribution in the single artificial tooth system. A maximum load difference of about 2% occurred in the vertical load by a mechanical test. This study showed that the hollow abutment screw may be an alternative to the conventional abutment screws because this is designed for easy retrieval and that both abutment screws showed no significant difference in the mechanical tests and in the FEA.

  16. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

    Science.gov (United States)

    Kim, Bongju; Shin, Yoo Jin

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA) and mechanical test. In the FEA results, both types of abutment screws showed similar stress distribution in the single artificial tooth system. A maximum load difference of about 2% occurred in the vertical load by a mechanical test. This study showed that the hollow abutment screw may be an alternative to the conventional abutment screws because this is designed for easy retrieval and that both abutment screws showed no significant difference in the mechanical tests and in the FEA. PMID:29065610

  17. Displaced proximal humeral fractures: an Indian experience with locking plates

    Directory of Open Access Journals (Sweden)

    Aggarwal Sameer

    2010-08-01

    Full Text Available Abstract Background The treatment of displaced proximal humerus fractures, especially in elderly, remains controversial. The objective of this study was to evaluate functional outcome of locking plate used for fixation of these fractures after open reduction. We also attempted to evaluate the complications and predictors of loss of fixation for such an implant. Methods Over two and a half years, 56 patients with an acute proximal humerus fracture were managed with locking plate osteosynthesis. 47 of these patients who completed a minimum follow up of 1 year were evaluated using Constant score calculation. Statistical analysis was done using SPSS 16 and a p value of less than 0.05 was taken as statistically significant. Results The average follow up period was around 21.5 months. Outcomes were excellent in 17%, good in 38.5%, moderate in 34% while poor in 10.5%. The Constant score was poorer for AO-OTA type 3 fractures as compared to other types. The scores were also inferior for older patients (> 65 years old. Complications included screw perforation of head, AVN, subacromial impingement, loss of fixation, axillary nerve palsy and infection. A varus malalignment was found to be a strong predictor of loss of fixation. Conclusion Locking plate osteosynthesis leads to satisfactory functional outcomes in all the patients. Results are better than non locking plates in osteoporotic fractures of the elderly. However the surgery has steep learning curve and various complications could be associated with its use. Nevertheless we believe that a strict adherence to the principles of locking plate use can ensure good result in such challenging fractures.

  18. Automatic locking radioisotope camera lock

    International Nuclear Information System (INIS)

    Rosauer, P.J.

    1978-01-01

    The lock of the present invention secures the isotope source in a stored shielded condition in the camera until a positive effort has been made to open the lock and take the source outside of the camera and prevents disconnection of the source pigtail unless the source is locked in a shielded condition in the camera. It also gives a visual indication of the locked or possible exposed condition of the isotope source and prevents the source pigtail from being completely pushed out of the camera, even when the lock is released. (author)

  19. One-stage lengthening using a locked nailing technique for distal femoral shaft nonunions associated with shortening.

    Science.gov (United States)

    Wu, Chi-Chuan; Lee, Zhon-Liau

    2004-02-01

    To assess the effectiveness of a one-stage lengthening using a locked nail technique for the treatment of distal femoral shaft nonunions associated with shortening. Retrospective. University hospital. During a 6-year period, 36 distal femoral shaft nonunions associated with shortening (>1.5 cm) were treated by the one-stage lengthening technique. Indications for this technique were distal femoral shaft aseptic or quiescent infected nonunions, 1.5-5 cm shortening, and a fracture level suitable for the insertion of two distal locked screws. The surgical technique involved skeletal traction using the femoral condyle, local débridement, lengthening by lengthening was 2.5 cm (range 1.5-3.5 cm). One-stage lengthening using the locked nailing technique to treat distal femoral shaft nonunions associated with shortening can achieve a high success rate and low complication rate. The key to successful treatment is the patient's complete cooperation with strictly protected weight bearing until the fracture has healed.

  20. Biomechanical testing of a hybrid locking plate fixation of equine sesamoid osteotomies.

    Science.gov (United States)

    Almeida da Silveira, E; Levasseur, A; Lacourt, M; Elce, Y; Petit, Y

    2014-01-01

    To compare the biomechanical properties of a hybrid locking compression plate (LCP) construct with the compression screw technique as a treatment for transverse mid-body proximal sesamoid bone fractures. Ten paired forelimbs from abattoir horses were used. The medial proximal sesamoid bone of each limb was osteotomized transversely and randomly assigned, to either repair with a two-hole 3.5 mm LCP or a 4.5 mm cortical screw placed in lag fashion. Each limb was tested biomechanically by axial loading in single cycle until failure. The point of failure was evaluated from the load-displacement curves. Then a gross evaluation and radiographs were performed to identify the mode of failure. The loads to failure of limbs repaired with the hybrid LCP construct (4968 N ± 2167) and the limbs repaired with the screw technique (3009 N ± 1091) were significantly different (p fracture of the apical fragment of the proximal sesamoid bone. The LCP technique has potential to achieve a better fracture stability and healing when applied to mid-body fractures of the proximal sesamoid bone. Further testing, particularly fatigue resistance is required to corroborate its potential as a treatment option for mid-body fractures of the proximal sesamoid bone.

  1. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

    OpenAIRE

    Sim, Bo Kyun; Kim, Bongju; Kim, Min Jeong; Jeong, Guk Hyun; Ju, Kyung Won; Shin, Yoo Jin; Kim, Man Yong; Lee, Jong-Ho

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access ...

  2. Extraction of sunflower oil by twin screw extruder: screw configuration and operating condition effects

    Energy Technology Data Exchange (ETDEWEB)

    Kartika, I.A. [FATETA-IPB, Bogor (Indonesia). Department of Agroindustrial Technology; Pontalier, P.Y.; Rigal, L. [Laboratoire de Chimie Agro-Industrielle, UMR 1010 INRA/INP-ENSIACET, Toulouse (France)

    2006-12-15

    The objective of this study was to investigate the screw configuration allowing oil extraction from sunflower seeds with a twin-screw extruder. Experiments were conducted using a co-rotating twin-screw extruder. Five screw profiles were examined to define the best performance (oil extraction yield, specific mechanical energy and oil quality) by studying the influence of operating conditions, barrel temperature, screw speed and feed rate. Generally, the position and spacing between two reversed screw elements affected oil extraction yield. An increase of oil extraction yield was observed as the reversed screw elements were moved with increased spacing between two elements and with smaller pitch elements. In addition, oil extraction yield increased as barrel temperature, screw speed and feed rate were decreased. Highest oil extraction yield (85%) with best cake meal quality (residual oil content lower than 13%) was obtained under operating conditions of 120 {sup o}C, 75 rpm and 19 kg/h. Furthermore, the operating parameters influenced energy input. A decrease in barrel temperature and feed rate followed by an increase in screw speed increased energy input, particularly specific mechanical energy input. Effect of the operating parameters on oil quality was less important. In all experiments tested, the oil quality was very good. The acid value was below 2 mg of KOH/g of oil and total phosphorus content was low, below 100 mg/kg. (author)

  3. [The rotationally stable screw-anchor with trochanteric stabilizing plate (RoSA/TSP) : First results in unstable trochanteric femur fractures].

    Science.gov (United States)

    Maier, K-J; Bücking, B; Horst, K; Andruszkow, H; Hildebrand, F; Knobe, M

    2017-12-01

    In unstable trochanteric fractures, the extramedullary rotationally stable screw-anchor (RoSA) combines the benefits of the load and rotational stability of the blade with the advantages of the screw (pull-out resistance, compression capability) in a single load carrier, and was designed to prevent femoral neck shortening by using an additional locked trochanteric stabilizing plate (TSP). The aim of the current prospective cohort study was the clinical evaluation of the RoSA/TSP system regarding the mechanical re-operation rate and the amount of postoperative femoral neck shortening. From September 2011 to January 2014 80 patients with unstable trochanteric fractures underwent internal extramedullary fixation with the RoSA/TSP (Königsee Implantate GmbH, Allendorf, Germany). Due to fracture stability and after induction of compression, additional long locked antitelescoping screws (AT, n = 1-4) were placed reaching the femoral head. Radiological (femoral neck shortening) and clinical re-examination of patients (n = 61) was performed 6-10 weeks and 6-10 months later. In the 61 re-examined patients (76 %) femoral neck shortening was very low with 2 mm 6-10 months after operation. Re-operations occurred in 8 % (n = 6) and in 4 % (n = 3) as prophylactic surgical intervention. Whereas one-third (4 %) of re-operations occurred due to iatrogenic surgical problems from the first operation two-thirds of patients (8 %) had a re-operation due to delay of bone union (3× nonunion, 3 planned removals of AT-screws to improve healing). The in-hospital mortality was 3 % (n = 2). The fixation of unstable trochanteric femur fractures using the RoSA/TSP in a first clinical setting led to a great primary stability, with significant advantages with regard to limited femoral neck shortening. However, the rigidity of the construct with its consequences regarding bone healing can be challenging for the surgeon. Nevertheless, in some cases of revision it could be beneficial

  4. The pullout performance of pedicle screws

    CERN Document Server

    Demir, Teyfik

    2015-01-01

    This brief book systematically discusses all subjects that affect the pullout strength of pedicle screws. These screws are used in spinal surgeries to stabilize the spine. The holding strength of the pedicle screw is vital since loosening of the pedicle screws can cause revision surgeries. Once the pedicle screw is pulled out, it is harder to obtain same stabilization for the fused vertebrae. The book reviews the effect of screw designs, application techniques, cement augmentation, coating of the screw and test conditions on the pullout strength. The studies with finite element analysis were also included.

  5. Development of load calculation techniques on screw and screw press energy consumption

    OpenAIRE

    Татарьянц, Максим Сергеевич; Завинский, Сергей Иванович; Трошин, Алексей Георгиевич

    2015-01-01

    The process of pressing of wood chips in screw machines is researched. It is defined processes taking place in different parts of the screw, formulas allowing to calculate the loads acting on the screw flights, as well as to determine the power required for compression. The unit costs of energy consumption and raw materials in the degree of heat pressing are determined

  6. Outer Rail for Wall Plate Covering

    DEFF Research Database (Denmark)

    2013-01-01

    including an abutment part, which extends inwards from the inner side of the retention web such as to form an abutment surface for the respective screw web when the latter is positioned to be retained in the retention device, and extends from the abutment part into a locking part, which extends at an angle...... to the abutment part and at a distance from the respective retention web. Each locking part comprising a first resilient locking pin adapted to lock a first screw web configuration and a second, separate resilient locking pin adapted to lock a second screw web configuration, the first and second screw web...

  7. Radiation-Independent Distal Locking Screw Insertion Using Dual Nail Insertion Handle: Is it a Reliable Method?

    Directory of Open Access Journals (Sweden)

    Adel Abdel Azim Foda

    2017-06-01

    Conclusion: This technique is not reliable enough to replace the classic radiation-dependent free-hand technique. Further development of this idea is needed to get a perfect radiation-independent distal locking technique.

  8. 2D and 3D assessment of sustentaculum tali screw fixation with or without Screw Targeting Clamp.

    Science.gov (United States)

    De Boer, A Siebe; Van Lieshout, Esther M M; Vellekoop, Leonie; Knops, Simon P; Kleinrensink, Gert-Jan; Verhofstad, Michael H J

    2017-12-01

    Precise placement of sustentaculum tali screw(s) is essential for restoring anatomy and biomechanical stability of the calcaneus. This can be challenging due to the small target area and presence of neurovascular structures on the medial side. The aim was to evaluate the precision of positioning of the subchondral posterior facet screw and processus anterior calcanei screw with or without a Screw Targeting Clamp. The secondary aim was to evaluate the added value of peroperative 3D imaging over 2D radiographs alone. Twenty Anubifix™ embalmed, human anatomic lower limb specimens were used. A subchondral posterior facet screw and a processus anterior calcanei screw were placed using an extended lateral approach. A senior orthopedic trauma surgeon experienced in calcaneal fracture surgery and a senior resident with limited experience in calcaneal surgery performed screw fixation in five specimens with and in five specimens without the clamp. 2D lateral and axial radiographs and a 3D recording were obtained postoperatively. Anatomical dissection was performed postoperatively as a diagnostic golden standard in order to obtain the factual screw positions. Blinded assessment of quality of fixation was performed by two surgeons. In 2D, eight screws were considered malpositioned when placed with the targeting device versus nine placed freehand. In 3D recordings, two additional screws were malpositioned in each group as compared to the golden standard. As opposed to the senior surgeon, the senior resident seemed to get the best results using the Screw Targeting Clamp (number of malpositioned screws using freehand was eight, and using the targeting clamp five). In nine out of 20 specimens 3D images provided additional information concerning target area and intra-articular placement. Based on the 3D assessment, five additional screws would have required repositioning. Except for one, all screw positions were rated equally after dissection when compared with 3D examinations

  9. Frictional performance of ball screw

    International Nuclear Information System (INIS)

    Nakashima, Katuhiro; Takafuji, Kazuki

    1985-01-01

    As feed screws, ball screws have become to be adopted in place of trapezoidal threads. The structure of ball screws is complex, but those are the indispensable component of NC machine tools and machining centers, and are frequently used for industrial robots. As the problems in the operation of ball screws, there are damage, life and the performance related to friction. As to the damage and life, though there is the problem of the load distribution on balls, the results of the research on rolling bearings are applied. The friction of ball screws consists of the friction of balls and a spiral groove, the friction of a ball and a ball, the friction in a ball-circulating mechanism and the viscous friction of lubricating oil. It was decided to synthetically examine the frictional performance of ball screws, such as driving torque, the variation of driving torque, efficiency, the formation of oil film and so on, under the working condition of wide range, using the screws with different accuracy and the nuts of various circuit number. The experimental setup and the processing of the experimental data, the driving performance of ball screws and so on are reported. (Kako, I.)

  10. Kinematics of Planetary Roller Screw Mechanism considering Helical Directions of Screw and Roller Threads

    Directory of Open Access Journals (Sweden)

    Shangjun Ma

    2015-01-01

    Full Text Available Based on the differential principle of thread transmission, an analytical model considering helical directions between screw and roller threads in planetary roller screw mechanism (PRSM is presented in this work. The model is critical for the design of PRSM with a smaller lead and a bigger pitch to realize a higher transmission accuracy. The kinematic principle of planetary transmission is employed to analyze the PRSM with different screw thread and roller thread directions. In order to investigate the differences with different screw thread and roller thread directions, the numerical model is developed by using the software Adams to validate the analytical solutions calculated by the presented model. The results indicate, when the helical direction of screw thread is identical with the direction of roller thread, that the lead of PRSM is unaffected regardless of whether sliding between screw and rollers occurs or not. Only when the direction of screw thread is reverse to the direction of roller thread, the design of PRSM with a smaller lead can be realized under a bigger pitch. The presented models and numerical simulation method can be used to research the transmission accuracy of PRSM.

  11. Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating.

    Science.gov (United States)

    Bacchi, Atais; Regalin, Alexandre; Bhering, Claudia Lopes Brilhante; Alessandretti, Rodrigo; Spazzin, Aloisio Oro

    2015-10-01

    The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at 10(6) cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.

  12. Sacroiliac Screw Fixation

    NARCIS (Netherlands)

    E.W. van den Bosch

    2003-01-01

    textabstractThe aim of this thesis is to evaluate three major aspects of the use of sacroiliac screws in patients with unstable pelvic ring fractures: the optimal technique for sacroiliac screw fixation, the reliability of peroperative fluoroscopy and the late results. We focused on the questions

  13. Complications of syndesmotic screw removal

    NARCIS (Netherlands)

    Schepers, Tim; van Lieshout, Esther M. M.; de Vries, Mark R.; van der Elst, Maarten

    2011-01-01

    Currently, the metallic syndesmotic screw is the gold standard in the treatment of syndesmotic disruption. Whether or not this screw needs to be removed remains debatable. The aim of the current study was to determine the complications which occur following routine removal of the syndesmotic screw

  14. Anterior screw fixation of a dislocated type II odontoid fracture facilitated by transoral and posterior cervical manual reduction.

    Science.gov (United States)

    Piedra, Mark P; Hunt, Matthew A; Nemecek, Andrew N

    2009-10-01

    Early fixation of type II odontoid fractures has been shown to provide high rates of long-term stabilization and osteosynthesis. In this report, the authors present the case of a patient with a locked type II odontoid fracture treated by anterior screw fixation facilitated by closed transoral and posterior cervical manual reduction. While transoral intraoperative reduction of a partially displaced odontoid fracture has previously been described, the authors present the first case utilizing this technique in the treatment of a completely dislocated type II odontoid fracture.

  15. General description and understanding of the nonlinear dynamics of mode-locked fiber lasers.

    Science.gov (United States)

    Wei, Huai; Li, Bin; Shi, Wei; Zhu, Xiushan; Norwood, Robert A; Peyghambarian, Nasser; Jian, Shuisheng

    2017-05-02

    As a type of nonlinear system with complexity, mode-locked fiber lasers are known for their complex behaviour. It is a challenging task to understand the fundamental physics behind such complex behaviour, and a unified description for the nonlinear behaviour and the systematic and quantitative analysis of the underlying mechanisms of these lasers have not been developed. Here, we present a complexity science-based theoretical framework for understanding the behaviour of mode-locked fiber lasers by going beyond reductionism. This hierarchically structured framework provides a model with variable dimensionality, resulting in a simple view that can be used to systematically describe complex states. Moreover, research into the attractors' basins reveals the origin of stochasticity, hysteresis and multistability in these systems and presents a new method for quantitative analysis of these nonlinear phenomena. These findings pave the way for dynamics analysis and system designs of mode-locked fiber lasers. We expect that this paradigm will also enable potential applications in diverse research fields related to complex nonlinear phenomena.

  16. Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw system

    Directory of Open Access Journals (Sweden)

    Lutz Weise

    2008-10-01

    Full Text Available Lutz Weise, Olaf Suess, Thomas Picht, Theodoros KombosNeurochirurgische Klinik, Charité – Universitätsmedizin Berlin, Berlin, GermanyObjective: Transpedicular screws are commonly and successfully used for posterior fixation in spinal instability, but their insertion remains challenging. Even using navigation techniques, there is a misplacement rate of up to 11%. The aim of this study was to assess the accuracy of a novel pedicle screw system.Methods: Thoracic and lumbar fusions were performed on 67 consecutive patients for tumor, trauma, degenerative disease or infection. A total of 326 pedicular screws were placed using a novel wire-guided, cannulated, polyaxial screw system (XIA Precision®, Stryker. The accuracy of placement was assessed post operatively by CT scan, and the patients were followed-up clinically for a mean of 16 months.Results: The total medio-caudal pedicle wall perforation rate was 9.2% (30/326. In 19 of these 30 cases a cortical breakthrough of less than 2 mm occurred. The misplacement rate (defined as a perforation of 2 mm or more was 3.37% (11/326. Three of these 11 screws needed surgical revision due to neurological symptoms or CSF leakage. There have been no screw breakages or dislocations over the follow up-period.Conclusion: We conclude that the use of this cannulated screw system for the placement of pedicle screws in the thoracic and lumbar spine is accurate and safe. The advantages of this technique include easy handling without a time-consuming set up. Considering the incidence of long-term screw breakage, further investigation with a longer follow-up period is necessary.Keywords: spinal instrumentation, pedicle screws, misplacement, pedicle wall perforation

  17. Scaphoid Fracture Fixation with an Acutrak? Screw

    OpenAIRE

    Loving, Vilert A.; Richardson, Michael L.

    2015-01-01

    We report a case of fixation of a scaphoid fracture using an Acutrak? screw. This screw is cannulated and headless, which allows it to be implanted below the surface of the bone. It uses the same concept of variable thread pitch as the Herbert screw, but unlike the Herbert screw, is fully threaded, with continuously varying pitch along its length. This variable pitch creates constant compression across a fracture as the screw is advanced, and gives the screw its unique appearance. This featur...

  18. The effect of inferomedial screw on postoperative shoulder function and mechanical alignment in proximal humerus fractures.

    Science.gov (United States)

    Erdoğan, Murat; Desteli, Engin Eren; İmren, Yunus; Üztürk, Ali; Kılıç, Mesut; Sezgin, Hicabi

    2014-10-01

    The aim of the study was to evaluate the clinical and radiologic results of locking plate fixation with or without inferomedial screw (IMS) in surgically treated proximal humerus fractures. Thirty-six patients with displaced proximal humerus fractures from two centers were operated using locking plate. All of the fractures were classified according to the Neer classification. In 18 of the cases, an additional IMS running through the medial curvature of the surgical neck was used. There was no significant difference among both groups in terms of height, gender, weight, and mechanism of injury. The fractures were evaluated according to the radiographic and functional findings during follow-up period of 14 months in average (range 8-32 months). At the end of first year, shoulder radiographs were received and shoulder examinations were performed using ASES scores. Humeral head-shaft angles were measured by true AP projections. Head-shaft angle measurements were categorized as varus if 145. Mean time for fracture healing was 18 weeks. Complete union was achieved in 35 patients by the end of 6 months. In one of the 18 displaced proximal humerus fractures of IMS (+) group, the head-shaft angle was measured to be <125, whereas six patients had varus deviation in IMS (-) group at follow-up (p < 0.05). Mean ASES scores of IMS (+) group and IMS (-) group were 58.21 ± 5.82 and 38.61 ± 3.44, respectively (p < 0.001). Use of inferomedial screw running through the medial curvature of surgical neck prevents varus deformity and improves functional outcome after surgical treatment for proximal humerus fractures.

  19. In vitro evaluation of force-expansion characteristics in a newly designed orthodontic expansion screw compared to conventional screws

    Directory of Open Access Journals (Sweden)

    Oshagh Morteza

    2009-01-01

    Full Text Available Objective : Expansion screws like Hyrax, Haas and other types, produce heavy interrupted forces which are unfavorable for dental movement and could be harmful to the tooth and periodontium. The other disadvantage of these screws is the need for patient cooperation for their regular activation. The purpose of this study was to design a screw and compare its force- expansion curve with other types. Materials and Methods : A new screw was designed and fabricated in the same dimension, with conventional types, with the ability of 8 mm expansion (Free wire length: 12 mm, initial compression: 4.5 mm, spring wire diameter: 0.4 mm, spring diameter: 3 mm, number of the coils: n0 ine, material: s0 tainless steel. In this in vitro study, the new screw was placed in an acrylic orthodontic appliance, and after mounting on a stone cast, the force-expansion curve was evaluated by a compression test machine and compared to other screws. Results : Force-expansion curve of designed screw had a flatter inclination compared to other screws. Generally it produced a light continuous force (two to 3.5 pounds for every 4 mm of expansion. Conclusion : In comparison with heavy and interrupted forces of other screws, the newly designed screw created light and continuous forces.

  20. FUNCTIONAL OUTCOME OF SUPRACONDYLAR FRACTURES OF FEMUR MANAGED BY OPEN REDUCTION AND INTERNAL FIXATION WITH LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    Madhusudhana

    2015-10-01

    Full Text Available INTRODUCTION : Incidence of distal femur fractures is approximately 37 per 1 , 00,000 person - years.¹Distal femoral fractures has two different injury mechanisms, high energy trauma and low energy trauma. In high - energy trauma, the problem of restoring the function in a destroyed knee joint persists. Complex knee ligament injuries frequently occur additionally to extensive cartilage injuries. In elderly patients, extreme osteoporosis represents a particular problem for anchoring the implant. 2 Supracondylar and inter condylar fractures often are unstable and comminuted and tend to occur in the elderly or those with multiple injuries. Treatment options are many with varied results. The final outcome would depend upon the type of fracture, stabilization of fixation and and perhaps patient general condition. 3 The options for operative treatment are traditional plating techniques that require compression of the implant to the femoral shaft (blade plate, Dynamic Condylar Screw, non - locking condylar buttress plate, antegrade nailing fixation, retrograde nailing, sub muscular locked internal fixation and external fixation. 4 However, as the complexity of fractures needing treatment has changed from simple extra - articular supra - condylar types to inter - condylar and metaphyseal comminuted types, these implants may not be ideal. Double plating, and more recently, locked plating techniques have been advocated 5 . However with double plating there is often extensive soft tissue stripping on both sides of the femur, resulting in reduced blood supply and potential non - union and failure of the implants 6 . The LCP is a single beam construct where the strength of its fixation is equal to the sum of all screw - bone interfaces rather than a single screw’s axial stiffness or pullout resistance as seen in unlocked plates 7,8 . Its unique biomechanical function is based on splinting rather than compression resulting in flexible stabilization

  1. Sinking and fit of abutment of locking taper implant system

    Science.gov (United States)

    Moon, Seung-Jin; Kim, Hee-Jung; Son, Mee-Kyoung

    2009-01-01

    STATEMENT OF PROBLEM Unlike screw-retention type, fixture-abutment retention in Locking taper connection depends on frictional force so it has possibility of abutment to sink. PURPOSE In this study, Bicon® Implant System, one of the conical internal connection implant system, was used with applying loading force to the abutments connected to the fixture. Then the amount of sinking was measured. MATERIAL AND METHODS 10 Bicon® implant fixtures were used. First, the abutment was connected to the fixture with finger force. Then it was tapped with a mallet for 3 times and loads of 20 kg corresponding to masticatory force using loading application instrument were applied successively. The abutment state, slightly connected to the fixture without pressure was considered as a reference length, and every new abutment length was measured after each load's step was added. The amount of abutment sinking (mm) was gained by subtracting the length of abutment-fixture under each loading condition from reference length. RESULTS It was evident, that the amount of abutment sinking in Bicon® Implant System increased as loads were added. When loads of 20 kg were applied more than 5 - 7 times, sinking stopped at 0.45 ± 0.09 mm. CONCLUSION Even though locking taper connection type implant shows good adaption to occlusal force, it has potential for abutment sinking as loads are given. When locking taper connection type implant is used, satisfactory loads are recommended for precise abutment location. PMID:21165262

  2. Geothermal ORC Systems Using Large Screw Expanders

    OpenAIRE

    Biederman, Tim R.; Brasz, Joost J.

    2014-01-01

    Geothermal ORC Systems using Large Screw Expanders Tim Biederman Cyrq Energy Abstract This paper describes a low-temperature Organic Rankine Cycle Power Recovery system with a screw expander a derivative of developed of Kaishan's line of screw compressors, as its power unit. The screw expander design is a modified version of its existing refrigeration compressor used on water-cooled chillers. Starting the ORC development program with existing refrigeration screw compre...

  3. The applicability of PEEK-based abutment screws.

    Science.gov (United States)

    Schwitalla, Andreas Dominik; Abou-Emara, Mohamed; Zimmermann, Tycho; Spintig, Tobias; Beuer, Florian; Lackmann, Justus; Müller, Wolf-Dieter

    2016-10-01

    The high-performance polymer PEEK (poly-ether-ether-ketone) is more and more being used in the field of dentistry, mainly for removable and fixed prostheses. In cases of screw-retained implant-supported reconstructions of PEEK, an abutment screw made of PEEK might be advantageous over a conventional metal screw due to its similar elasticity. Also in case of abutment screw fracture, a screw of PEEK could be removed more easily. M1.6-abutment screws of four different PEEK compounds were subjected to tensile tests to set their maximum tensile strengths in relation to an equivalent stress of 186MPa, which is aused by a tightening torque of 15Ncm. Two screw types were manufactured via injection molding and contained 15% short carbon fibers (sCF-15) and 40% (sCF-40), respectively. Two screw types were manufactured via milling and contained 20% TiO2 powder (TiO2-20) and >50% parallel orientated, continuous carbon fibers (cCF-50). A conventional abutments screw of Ti6Al4V (Ti; CAMLOG(®) abutment screw, CAMLOG, Wimsheim, Germany) served as control. The maximum tensile strength was 76.08±5.50MPa for TiO2-20, 152.67±15.83MPa for sCF-15, 157.29±20.11MPa for sCF-40 and 191.69±36.33MPa for cCF-50. The maximum tensile strength of the Ti-screws amounted 1196.29±21.4MPa. The results of the TiO2-20 and the Ti screws were significantly different from the results of the other samples, respectively. For the manufacturing of PEEK abutment screws, PEEK reinforced by >50% continuous carbon fibers would be the material of choice. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Pull out Strength of Dual Outer Diameter Pedicle Screws Compared to Uncemented and Cemented Standard Pedicle Screws: A Biomechanical in vitro Study.

    Science.gov (United States)

    Lorenz, Andrea; Leichtle, Carmen I; Frantz, Sandra; Bumann, Marte; Tsiflikas, Ilias; Shiozawa, Thomas; Leichtle, Ulf G

    2017-05-01

    To analyze the potential of the dual outer diameter screw and systematically evaluate the pull-out force of the dual outer diameter screw compared to the uncemented and cemented standard pedicle screws with special regard to the pedicle diameter and the vertebra level. Sixty vertebrae of five human spines (T 6 -L 5 ) were sorted into three study groups for pairwise comparison of the uncemented dual outer diameter screw, the uncemented standard screw, and the cemented standard screw, and randomized with respect to bone mineral density (BMD) and vertebra level. The vertebrae were instrumented, insertion torque was determined, and pull-out testing was performed using a material testing machine. Failure load was evaluated in pairwise comparison within each study group. The screw-to-pedicle diameter ratio was determined and the uncemented dual outer diameter and standard screws were compared for different ratios as well as vertebra levels. Significantly increased pull-out forces were measured for the cemented standard screw compared to the uncemented standard screw (+689 N, P dual outer diameter screw (+403 N, P dual outer diameter screw to the uncemented standard screw in the total study group, a distinct but not significant increase was measured (+149 N, P = 0.114). Further analysis of these two screws, however, revealed a significant increase of pull-out force for the dual outer diameter screw in the lumbar region (+247 N, P = 0.040), as well as for a screw-to-pedicle diameter ratio between 0.6 and 1 (+ 488 N, P = 0.028). For clinical application, cement augmentation remains the gold standard for increasing screw stability. According to our results, the use of a dual outer diameter screw is an interesting option to increase screw stability in the lumbar region without cement augmentation. For the thoracic region, however, the screw-to-pedicle diameter should be checked and attention should be paid to screw cut out, if the dual outer diameter screw is considered.

  5. Undertapping of Lumbar Pedicle Screws Can Result in Tapping With a Pitch That Differs From That of the Screw, Which Decreases Screw Pullout Force.

    Science.gov (United States)

    Bohl, Daniel D; Basques, Bryce A; Golinvaux, Nicholas S; Toy, Jason O; Matheis, Erika A; Bucklen, Brandon S; Grauer, Jonathan N

    2015-06-15

    Survey of spine surgeons and biomechanical comparison of screw pullout forces. To investigate what may be a suboptimal practice regularly occurring in spine surgery. In order for a tap to function in its intended manner, the pitch of the tap should be the same as the pitch of the screw. Undertapping has been shown to increase the pullout force of pedicle screws compared with line-to-line tapping. However, given the way current commercial lumbar pedicle screw systems are designed, undertapping may result in a tap being used that has a different pitch from that of the screw (incongruent pitch). A survey asked participants questions to estimate the proportion of cases each participant performed in the prior year using various hole preparation techniques. Participant responses were interpreted in the context of manufacturing specifications of specific instrumentation systems. Screw pullout forces were compared between undertapping with incongruent pitch and undertapping with congruent pitch using 0.16 g/cm polyurethane foam block and 6.5-mm screws. Of the 3679 cases in which participants reported tapping, participants reported line-to-line tapping in 209 cases (5%), undertapping with incongruent pitch in 1156 cases (32%), and undertapping with congruent pitch in 2314 cases (63%). The mean pullout force for undertapping with incongruent pitch was 56 N (8%) less than the mean pullout force for undertapping with congruent pitch. This is equivalent to 13 lb. This study estimates that for about 1 out of every 3 surgical cases with tapping of lumbar pedicle screws in the United States, hole preparation is being performed by undertapping with incongruent pitch. This study also shows that undertapping with incongruent pitch results in a decrease in pullout force by 8% compared with undertapping with congruent pitch. Steps should be taken to correct this suboptimal practice. 3.

  6. Measurement of Tip Apex Distance and Migration of Lag Screws and Novel Blade Screw Used for the Fixation of Intertrochanteric Fractures.

    Directory of Open Access Journals (Sweden)

    Jesse Chieh-Szu Yang

    Full Text Available Fixation with a dynamic hip screw (DHS is one of the most common methods for stabilizing intertrochanteric fractures, except for unstable and reverse oblique fracture types. However, failure is often observed in osteoporotic patients whereby the lag screw effectively 'cuts out' through the weak bone. Novel anti-migration blades have been developed to be used in combination with a lag screw ('Blade Screw' to improve the fixation strength in osteoporotic intertrochanteric fractures. An in-vitro biomechanical study and a retrospective clinical study were performed to evaluate lag screw migration when using the novel Blade Screw and a traditional threaded DHS. The biomechanical study showed both the Blade Screw and DHS displayed excessive migration (≥10 mm before reaching 20,000 loading cycles in mild osteoporotic bone, but overall migration of the Blade Screw was significantly less (p ≤ 0.03. Among the patients implanted with a Blade Screw in the clinical study, there was no significant variation in screw migration at 3-months follow-up (P = 0.12. However, the patient's implanted with a DHS did display significantly greater migration (P<0.001 than those implanted with the Blade Screw. In conclusion, the Blade Screw stabilizes the bone fragments during dynamic loading so as to provide significantly greater resistance to screw migration in patients with mild osteoporosis.

  7. Comparison of effectiveness between cork-screw and peg-screw electrodes for transcranial motor evoked potential monitoring using the finite element method.

    Science.gov (United States)

    Tomio, Ryosuke; Akiyama, Takenori; Ohira, Takayuki; Yoshida, Kazunari

    2016-01-01

    Intraoperative monitoring of motor evoked potentials by transcranial electric stimulation is popular in neurosurgery for monitoring motor function preservation. Some authors have reported that the peg-screw electrodes screwed into the skull can more effectively conduct current to the brain compared to subdermal cork-screw electrodes screwed into the skin. The aim of this study was to investigate the influence of electrode design on transcranial motor evoked potential monitoring. We estimated differences in effectiveness between the cork-screw electrode, peg-screw electrode, and cortical electrode to produce electric fields in the brain. We used the finite element method to visualize electric fields in the brain generated by transcranial electric stimulation using realistic three-dimensional head models developed from T1-weighted images. Surfaces from five layers of the head were separated as accurately as possible. We created the "cork-screws model," "1 peg-screw model," "peg-screws model," and "cortical electrode model". Electric fields in the brain radially diffused from the brain surface at a maximum just below the electrodes in coronal sections. The coronal sections and surface views of the brain showed higher electric field distributions under the peg-screw compared to the cork-screw. An extremely high electric field was observed under cortical electrodes. Our main finding was that the intensity of electric fields in the brain are higher in the peg-screw model than the cork-screw model.

  8. Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study

    Directory of Open Access Journals (Sweden)

    Herrera Antonio

    2010-06-01

    Full Text Available Abstract Background Primary stability of the graft is essential in anterior cruciate ligament surgery. An optimal method of fixation should be easy to insert and provide great resistance against pull-out forces. A controlled laboratory study was designed to test the primary stability of ACL tendinous grafts in the tibial tunnel. The correlation between resistance to traction forces and the cross-section and length of the screw was studied. Methods The tibial phase of ACL reconstruction was performed in forty porcine tibias using digital flexor tendons of the same animal. An 8 mm tunnel was drilled in each specimen and two looped tendons placed as graft. Specimens were divided in five groups according to the diameter and length of the screw used for fixation. Wedge interference screws were used. Longitudinal traction was applied to the graft with a Servohydraulic Fatigue System. Load and displacement were controlled and analyzed. Results The mean loads to failure for each group were 295,44 N (Group 1; 9 × 23 screw, 564,05 N (Group 2; 9 × 28, 614,95 N (Group 3; 9 × 35, 651,14 N (Group 4; 10 × 28 and 664,99 (Group 5; 10 × 35. No slippage of the graft was observed in groups 3, 4 and 5. There were significant differences in the load to failure among groups (ANOVA/P Conclusions Longer and wider interference screws provide better fixation in tibial ACL graft fixation. Short screws (23 mm do not achieve optimal fixation and should be implanted only with special requirements.

  9. 49 CFR 236.330 - Locking dog of switch-and-lock movement.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking dog of switch-and-lock movement. 236.330 Section 236.330 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.330 Locking dog of switch-and-lock movement. Locking dog of switch-and-lock...

  10. Comparison of open reduction versus minimally invasive surgical approaches on screw position in canine sacroiliac lag-screw fixation.

    Science.gov (United States)

    Déjardin, Loïc M; Marturello, Danielle M; Guiot, Laurent P; Guillou, Reunan P; DeCamp, Charles E

    2016-07-19

    To compare accuracy and consistency of sacral screw placement in canine pelves treated for sacroiliac luxation with open reduction and internal fixation (ORIF) or minimally invasive osteosynthesis (MIO) techniques. Unilateral sacroiliac luxations created experimentally in canine cadavers were stabilized with an iliosacral lag screw applied via ORIF or MIO techniques (n = 10/group). Dorsoventral and craniocaudal screw angles were measured using computed tomography multiplanar reconstructions in transverse and dorsal planes, respectively. Ratios between pilot hole length and sacral width (PL/SW-R) were obtained. Data between groups were compared statistically (p sacroiliac luxations provides more accurate and consistent sacral screw placement than ORIF. With proper techniques, iatrogenic neurological damage can be avoided with both techniques. The PL /SW-R, which relates to safe screw fixation, also demonstrates that screw penetration of at least 60% of the sacral width is achievable regardless of surgical approach. These findings, along with the limited dissection needed for accurate sacral screw placement, suggest that MIO of sacroiliac luxations is a valid alternative to ORIF.

  11. Percutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture

    OpenAIRE

    Wu, Ai-Min; Jin, Hai-Ming; Lin, Zhong-Ke; Chi, Yong-Long; Wang, Xiang-Yang

    2017-01-01

    Background The objective of this study is to investigate the outcomes and safety of using percutaneous anterior C1/2 transarticular screw fixation as a salvage technique for odontoid fracture if percutaneous odontoid screw fixation fails. Methods Fifteen in 108 odontoid fracture patients (planned to be treated by percutaneous anterior odontoid screw fixation) were failed to introduce satisfactory odontoid screw trajectory. To salvage this problem, we chose the percutaneous anterior C1/2 trans...

  12. Evaluation of the Effect of Fixation Angle between Polyaxial Pedicle Screw Head and Rod on the Failure of Screw-Rod Connection

    Directory of Open Access Journals (Sweden)

    Engin Çetin

    2015-01-01

    Full Text Available Introduction. Polyaxial screws had been only tested according to the ASTM standards (when they were perpendicularly positioned to the rod. In this study, effects of the pedicle screws angled fixation to the rod on the mechanical properties of fixation were investigated. Materials and Method. 30 vertically fixed screws and 30 screws fixed with angle were used in the study. Screws were used in three different diameters which were 6.5 mm, 7.0 mm, and 7.5 mm, in equal numbers. Axial pull-out and flexion moment tests were performed. Test results compared with each other using appropriate statistical methods. Results. In pull-out test, vertically fixed screws, in 6.5 mm and 7.0 mm diameter, had significantly higher maximum load values than angled fixed screws with the same diameters (P<0.01. Additionally, vertically fixed screws, in all diameters, had significantly greater stiffness according to corresponding size fixed with angle (P<0.005. Conclusion. Fixing the pedicle screw to the rod with angle significantly decreased the pull-out stiffness in all diameters. Similarly, pedicle screw instrumentation fixed with angle decreased the minimum sagittal angle between the rod and the screw in all diameters for flexion moment test but the differences were not significant.

  13. A comparison of locked versus nonlocked Enders rods for length unstable pediatric femoral shaft fractures.

    Science.gov (United States)

    Ellis, Henry Bone; Ho, Christine A; Podeszwa, David A; Wilson, Philip L

    2011-12-01

    Stainless steel flexible Enders rods have been used for intramedullary fixation of pediatric femur fractures with good success. Despite intraoperative anatomic alignment, length unstable femur fractures can present postoperatively with fracture shortening. The purpose of this study was to review all length unstable pediatric femoral shaft fractures in which Enders rods were used and compare those that were locked to those that were not locked. A retrospective clinical and radiographic review of all patients at a single institution undergoing flexible intramedullary fixation for length unstable femoral shaft fractures from 2001 to 2008. A length unstable fracture was defined as either a comminuted fracture or a spiral fracture longer than twice the diameter of the femoral shaft. A total of 107 length unstable femoral shaft fractures fixed with Enders rods were identified, of which 37 cases (35%) had both Enders rods "locked" through the eyelet in the distal femur with a 2.7 mm fully threaded cortical screw. Patient demographics, clinical course, complications, fracture characteristics, and radiographic outcomes were compared for the locked and nonlocked groups. There were no statistical differences between the groups in demographic data, operative variables, fracture pattern, fracture location, time to union, femoral alignment, or major complications. Shortening of the femur and nail migration measured at 1 to 6 weeks postoperatively was significantly greater for the nonlocked cases. The medial and lateral locked Enders rods moved 1.3 and 1.9 mm, respectively, and the unlocked Enders each moved 12.1 mm (P < 0.05). At final follow-up there were significantly more (P < 0.05) clinical complaints in nonlocked group, including limp, clinical shortening, and painful palpable rods. Locking Enders rods for length unstable pediatric fractures is an excellent option to prevent shortening and resulted in no additional complications, added surgical time, or increased blood loss

  14. Standard Waste Box Lid Screw Removal Option Testing

    International Nuclear Information System (INIS)

    Anast, Kurt Roy

    2016-01-01

    This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

  15. Standard Waste Box Lid Screw Removal Option Testing

    Energy Technology Data Exchange (ETDEWEB)

    Anast, Kurt Roy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

  16. Misplaced Cervical Screws Requiring Reoperation.

    Science.gov (United States)

    Peterson, Jeremy C; Arnold, Paul M; Smith, Zachary A; Hsu, Wellington K; Fehlings, Michael G; Hart, Robert A; Hilibrand, Alan S; Nassr, Ahmad; Rahman, Ra'Kerry K; Tannoury, Chadi A; Tannoury, Tony; Mroz, Thomas E; Currier, Bradford L; De Giacomo, Anthony F; Fogelson, Jeremy L; Jobse, Bruce C; Massicotte, Eric M; Riew, K Daniel

    2017-04-01

    A multicenter, retrospective case series. In the past several years, screw fixation of the cervical spine has become commonplace. For the most part, this is a safe, low-risk procedure. While rare, screw backout or misplaced screws can lead to morbidity and increased costs. We report our experiences with this uncommon complication. A multicenter, retrospective case series was undertaken at 23 institutions in the United States. Patients were included who underwent cervical spine surgery from January 1, 2005, to December 31, 2011, and had misplacement of screws requiring reoperation. Institutional review board approval was obtained at all participating institutions, and detailed records were sent to a central data center. A total of 12 903 patients met the inclusion criteria and were analyzed. There were 11 instances of screw backout requiring reoperation, for an incidence of 0.085%. There were 7 posterior procedures. Importantly, there were no changes in the health-related quality-of-life metrics due to this complication. There were no new neurologic deficits; a patient most often presented with pain, and misplacement was diagnosed on plain X-ray or computed tomography scan. The most common location for screw backout was C6 (36%). This study represents the largest series to tabulate the incidence of misplacement of screws following cervical spine surgery, which led to revision procedures. The data suggest this is a rare event, despite the widespread use of cervical fixation. Patients suffering this complication can require revision, but do not usually suffer neurologic sequelae. These patients have increased cost of care. Meticulous technique and thorough knowledge of the relevant anatomy are the best means of preventing this complication.

  17. Are We Underestimating the Significance of Pedicle Screw Misplacement?

    Science.gov (United States)

    Sarwahi, Vishal; Wendolowski, Stephen F; Gecelter, Rachel C; Amaral, Terry; Lo, Yungtai; Wollowick, Adam L; Thornhill, Beverly

    2016-05-01

    A retrospective review of charts, x-rays (XRs) and computed tomography (CT) scans was performed. To evaluate the accuracy of pedicle screw placement using a novel classification system to determine potentially significant screw misplacement. The accuracy rate of pedicle screw (PS) placement varies from 85% to 95% in the literature. This demonstrates technical ability but does not represent the impact of screw misplacement on individual patients. This study quantifies the rate of screw misplacement on a per-patient basis to highlight its effect on potential morbidity. A retrospective review of charts, XRs and low-dose CT scans of 127 patients who underwent spinal fusion with pedicle screws for spinal deformity was performed. Screws were divided into four categories: screws at risk (SAR), indeterminate misplacements (IMP), benign misplacements (BMP), accurately placed (AP). A total of 2724 screws were placed in 127 patients. A total of 2396 screws were placed accurately (87.96%). A total of 247 screws (9.07%) were BMP, 52 (1.91%) were IMP, and 29 (1.06%) were considered SAR. Per-patient analysis showed 23 (18.11%) of patients had all screws AP. Thirty-five (27.56%) had IMP and 18 (14.17%) had SAR. Risk factor analysis showed smaller Cobb angles increased likelihood of all screws being AP. Sub-analysis of adolescent idiopathic scoliotic patients showed no curve or patient characteristic that correlated with IMP or SAR. Over 40% of patients had screws with either some/major concern. Overall reported screw misplacement is low, but it does not reflect the potential impact on patient morbidity. Per-patient analysis reveals more concerning numbers toward screw misplacement. With increasing pedicle screw usage, the number of patients with misplaced screws will likely increase proportionally. Better strategies need to be devised for evaluation of screw placement, including establishment of a national database of deformity surgery, use of intra-operative image guidance, and

  18. Tricortical cervical inter-body screw fixation.

    Directory of Open Access Journals (Sweden)

    Goel A

    1997-01-01

    Full Text Available A new tricortical method of screw implantation for anterior cervical interbody plate fixation is described. The screws are placed obliquely such that they engage the anterior cortex of the body and traverse through the cortices adjoining the disc space. By this method the screws not only hold the plate firmly with a tricortical purchase, but by virtue of their course stabilize the two adjoining vertebral bodies by themselves. Sixteen patients were treated by this method. In three of these cases only tricortical screws without the metal plate were used for fixation. The advantages of the technique are discussed.

  19. The Use of Percutaneous Lumbar Fixation Screws for Bilateral Pedicle Fractures with an Associated Dislocation of a Lumbar Disc Prosthesis

    Directory of Open Access Journals (Sweden)

    William D. Harrison

    2013-01-01

    Full Text Available Study Design. Case report. Objective. To identify a safe technique for salvage surgery following complications of total disc replacement. Summary of Background Data. Lumbar total disc replacement (TDR is considered by some as the gold standard for discogenic back pain. Revision techniques for TDR and their complications are in their infancy. This case describes a successful method of fixation for this complex presentation. Methods and Results. A 48-year-old male with lumbar degenerative disc disease and no comorbidities. Approximately two weeks postoperatively for a TDR, the patient represented with acute severe back pain and the TDR polyethylene inlay was identified as dislocated anteriorly. Subsequent revision surgery failed immediately as the polyethylene inlay redislocated intraoperatively. Further radiology identified bilateral pedicle fractures, previously unseen on the plain films. The salvage fusion of L5/S1 reutilized the anterior approach with an interbody fusion cage and bone graft. The patient was then turned intraoperatively and redraped. The percutaneous pedicle screws were used to fix L5 to the sacral body via the paracoccygeal corridor. Conclusion. The robust locking screw in the percutaneous screw allowed a complete fixation of the pedicle fractures. At 3-year followup, the patient has an excellent result and has returned to playing golf.

  20. Treatment of proximal humerus fractures with locking plates: a systematic review.

    Science.gov (United States)

    Thanasas, Christos; Kontakis, George; Angoules, Antonios; Limb, David; Giannoudis, Peter

    2009-01-01

    Locking plates with special configuration for the anatomic region of the proximal humerus have been introduced recently to address the difficulties of stabilizing proximal humeral fractures. The purpose of this study was to carry out a systematic review of the literature on the efficacy and early to medium term functional results of locking plates for stabilization of proximal humeral fractures. Using the PubMed database, a systematic review of the English and German literature was carried out in order to assess the efficacy and complications related to the use of these plates and the patients' functional outcome, using the key words "locking plates proximal humeral fractures," "angular stability plates proximal humeral fractures," "PHILOS plate," and "LPHP plate." Our criteria for eligibility were clinical studies with more than ten cases followed-up, adult patients, and adequate data provided at least in terms of implant related complications. Articles written in English and German language were included. Exclusion criteria were: studies dealing exclusively with 2-part fractures (since this category has a more favorable outcome); experimental studies; case reports; and, literature other than English or German. Each one of the articles was evaluated for quality of the study using the Structured Effectiveness Quality Evaluation Scale (SEQES). Twelve studies including 791 patients met the inclusion criteria. Patients in these studies continued to improve up to one year, achieving a mean Constant score of 74.3. The incidence of the reported complications was: avascular necrosis 7.9%, screw cut-out 11.6% and re-operation rate 13.7%. The high incidence of cut-out may be secondary to the rigidity of the implant in combination with medial inadequate support, in cases compromised by severe underlying osteoporotic bone. Definition of indications for the use of locking plates and attention on technical aspects of applying them would help optimization of the results

  1. Accuracy of computer-assisted cervicle pedicle screw installation

    International Nuclear Information System (INIS)

    Zhang Honglei; Zhou Dongsheng; Jang Zhensong

    2009-01-01

    Objective: To investigate the accuracy of computer-assisted cervical pedicle screw installation and the reason of screw malposition. Methods: A total of 172 cervical pedicle screws were installed by computer-assisted navigation for 30 patients with lower cervical spinal diseases. All the patients were examined by X-ray and CT after operation. Screw's position and direction were measured on the sagittal and transectional images of intraoperative navigation and post-operative CT. Then linear regression analysis was taken between navigational and post-operative CT's images. Results: Two screws perforated the upper pedicle wall, 3 perforated the lateral pedicle wall.There was a positive linear correlation between navigational and post-operative CT's images. Conclusion: Computer-assisted navigation can provide the high accuracy of cervical pedicle screw installation and excursion phenomenon is reason of screw malposition. (authors)

  2. Comparison of Expansive Pedicle Screw and Polymethylmethacrylate-Augmented Pedicle Screw in Osteoporotic Sheep Lumbar Vertebrae: Biomechanical and Interfacial Evaluations

    OpenAIRE

    Liu, Da; Zhang, Yi; Zhang, Bo; Xie, Qing-yun; Wang, Cai-ru; Liu, Jin-biao; Liao, Dong-fa; Jiang, Kai; Lei, Wei; Pan, Xian-ming

    2013-01-01

    BACKGROUND: It was reported that expansive pedicle screw (EPS) and polymethylmethacrylate-augmented pedicle screw (PMMA-PS) could be used to increase screw stability in osteoporosis. However, there are no studies comparing the two kinds of screws in vivo. Thus, we aimed to compare biomechanical and interfacial performances of EPS and PMMA-PS in osteoporotic sheep spine. METHODOLOGY/PRINCIPAL FINDINGS: After successful induction of osteoporotic sheep, lumbar vertebrae in each sheep were random...

  3. Simple Technique for Removing Broken Pedicular Screws

    Directory of Open Access Journals (Sweden)

    A Agrawal

    2014-03-01

    Full Text Available The procedure for removing a broken pedicle screw should ideally be technically easy and minimally invasive, as any damage to the pedicle, during removal of the broken screw, may weaken the pedicle, thus compromising on the success of re-instrumentation. We describe the case of a 32-year old man who had undergone surgery for traumatic third lumbar vertebral body fracture three years prior to current admission and had developed the complication of pedicle screw breakage within the vertebral body. The patient underwent re-exploration and removal of the distal screws. Through a paravertebral incision and muscle separation, the screws and rods were exposed and the implants were removed.

  4. The effect of different screw-rod design on the anti-rotational torque: a biomechanical comparison of three conventional screw-rod constructs.

    Science.gov (United States)

    Huang, Zifang; Wang, Chongwen; Fan, Hengwei; Sui, Wenyuan; Li, Xueshi; Wang, Qifei; Yang, Junlin

    2017-07-28

    Screw-rod constructs have been widely used to correct spinal deformities, but the effects of different screw-rod systems on anti-rotational torque have not been determined. This study aimed to analyze the biomechanical effect of different rod-screw constructs on anti-rotational torque. Three conventional spinal screw-rod systems (Legacy, RF-F-10 and USSII) were used to test the anti-rotational torque in the material test machine. ANOVA was performed to evaluate the anti-rotational capacity of different pedicle screws-rod constructs. The anti-rotational torque of Legacy group, RF-F-10 group and USSII group were 12.3 ± 1.9 Nm, 6.8 ± 0.4 Nm, and 3.9 ± 0.8 Nm, with a P value lower than 0.05. This results indicated that the Legacy screws-rod construct could provide a highest anti-rotation capacity, which is 68% and 210% greater than RF-F-10 screw-rod construct and USSII screw-rod respectively. The anti-rotational torque may be mainly affected by screw cap and groove design. Our result showed the anti-rotational torque are: Legacy system > RF-F-10 system > USSII system, suggesting that appropriate rod-screw constructs selection in surgery may be vital for anti-rotational torque improvement and preventing derotation correction loss.

  5. Screw piles for cold climate foundations

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, R.; Sakr, M. [Almita Manufacturing Ltd., Edmonton, AB (Canada)

    2008-07-01

    Almita Manufacturing is an Alberta-based company that designs and builds screw piles with its own installation teams. It also engineers and supplies piles to numerous other companies and independent installers. The company services industries such as oil and gas; power transmission and distribution; and commercial construction. This presentation discussed the design and technical aspects of screw piles. A screw pile was defined as a steel pipe shaft with a 45 degree cut at the bottom and a formed helical plate welded to the outside of the pipe near the base and at a selected point on the shaft. The pile is screwed into the ground with a planetary drive head of suitable torque rating. The helical plate or helix helps facilitate the installation of the pile and gives the screw pile increased bearing capacity and pull-out resistance over a traditional straight-shaft pile. Screw piles were compared against cast in place concrete piles and steel driven piles. Screw piles were reported to have no tailings; no concrete curing time; no rebar, anchor belts, and no liners; and no dewatering. Screw piles can also be installed in all types of weather. Rhe Cree Burn Camp case study near Fort McMurray, Alberta was also presented. This residential camp and recreation complex consists of pre-fabricated units that make up three storey housing buildings and a single floor multi-use building. The case study provided information on soil; design parameter inputs; load testing program and pile configuration; geotechnical and structural design results; compression load test arrangement; pile test setup; and test results. The presentation also discussed fabrication as well as installation equipment. Various applications were also presented through a series of project pictures. Last, the presentation provided a simple cost analysis. tabs., figs.

  6. Causes and treatments of lag screw's cut out after intramedullary nailing osteosinthesis for trochanteric fractures.

    Science.gov (United States)

    Gazzotti, Gabriele; Matino, Giovanni; Tsatsis, Christos; Sacchetti, GianLuigi; Baudi, Paolo; Catani, Fabio

    2014-08-20

    Background. Superior cut-out of a lag screw remains a serious complication in the treatment of trochanteric or subtrochanteric fractures and it is related to many factors: the type of fracture, osteoporosis and the stability of fracture reduction. Little is known about the outcome after revision surgery for complications of the gamma nail. We assessed the outcome in patients who had revision surgery because of lag screw's cut out after gamma nailing for a trochanteric fracture.Material and Method. We present a study of 20 consecutive patients who underwent treatment after 20 cut-out of the lag screw fixation of a trochanteric fracture with Gamma Locking Nail from September 2004 to November 2010. In 16 patients hip prothesis was performed, in 1 the removal of the implant and in 3 the reosteosynthesis. We reviewed 13 patients: 10 total hip arthroplasty, 2 endoprothesis and 1 reosteosynthesis of nail and lag screw (mean follow up: 26 months, mean age: 73 years old), 7 patients died. Patients were reviewed retrospectively by an independent observer. Clinical evaluation was performed, Oxford score and Harris Hip score were measured. X-Ray examination was performed after a minimum of 12 months of follow up.Results. Mean Harris Hip Score mean was 67 and mean Oxford score was 32 in hip prothesis group (12 patients). We had several complications, Implant-related complications were: 2 ipometria > 2cm, 2 recurrent hip arthroplasty dislocations (1 reoperated), 4 persistent thigh pain. In only 4 patients none complications were observed. Another patient,  who had been subjected to reosteosinthesis, obtained better results (HHS:95, Oxford score:45) but with a 2 cm ipometria and occasional pain in the thigh.Conclusion. Cut out after gamma nail is consequent to biological or mechanical causes. Treatment of this complication is hip prosthesis (parzial or total hip arthroplasty), reosteosynthesis of the lag screw and/or the nail and the removal of the implant. Conversion to total

  7. Complications of syndesmotic screw removal

    NARCIS (Netherlands)

    T. Schepers (Tim); E.M.M. van Lieshout (Esther); M.R. de Vries (Mark); M. van der Elst (Maarten)

    2011-01-01

    textabstractBackground: Currently, the metallic syndesmotic screw is the gold standard in the treatment of syndesmotic disruption. Whether or not this screw needs to be removed remains debatable. The aim of the current study was to determine the complications which occur following routine removal of

  8. Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures - postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate.

    Science.gov (United States)

    Paulsson, Johnny; Stig, Josefine Corin; Olsson, Ola

    2017-08-24

    In treatment of unstable trochanteric fractures dynamic hip screw and Medoff sliding plate devices are designed to allow secondary fracture impaction, whereas intramedullary nails aim to maintain fracture alignment. Different treatment protocols are used by two similar Swedish regional emergency care hospitals. Dynamic hip screw is used for fractures considered as stable within the respective treatment protocol, whereas one treatment protocol (Medoff sliding plate/dynamic hip screw) uses biaxial Medoff sliding plate for unstable pertrochanteric fractures and uniaxial Medoff sliding plate for subtrochanteric fractures, the second (intramedullary nail/dynamic hip screw) uses intramedullary nail for subtrochanteric fractures and for pertrochanteric fractures with intertrochanteric comminution or subtrochanteric extension. All orthopedic surgeries are registered in a regional database. All consecutive trochanteric fracture operations during 2011-2012 (n = 856) and subsequent technical reoperations (n = 40) were derived from the database. Reoperations were analysed and classified into the categories adjustment (percutaneous removal of the locking screw of the Medoff sliding plate or the intramedullary nail, followed by fracture healing) or minor, intermediate (reosteosynthesis) or major (hip joint replacement, Girdlestone or persistent nonunion) technical complications. The relative risk of intermediate or major technical complications was 4.2 (1.2-14) times higher in unstable pertrochanteric fractures and 4.6 (1.1-19) times higher in subtrochanteric fractures with treatment protocol: intramedullary nail/dynamic hip screw, compared to treatment protocol: Medoff sliding plate/dynamic hip screw. Overall rates of intermediate and major technical complications in unstable pertrochanteric and subtrochanteric fractures were with biaxial Medoff sliding plate 0.68%, with uniaxial Medoff sliding plate 1.4%, with dynamic hip screw 3.4% and with intramedullary nail 7.2%. The

  9. Unified Impedance Model of Grid-Connected Voltage-Source Converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Harnefors, Lennart; Blaabjerg, Frede

    2018-01-01

    This paper proposes a unified impedance model of grid-connected voltage-source converters for analyzing dynamic influences of the Phase-Locked Loop (PLL) and current control. The mathematical relations between the impedance models in the different domains are first explicitly revealed by means...... of complex transfer functions and complex space vectors. A stationary (αβ-) frame impedance model is then proposed, which not only predicts the stability impact of the PLL, but reveals also its frequency coupling effect explicitly. Furthermore, the impedance shaping effect of the PLL on the current control...... results and theoretical analysis confirm the effectiveness of the stationary-frame impedance model....

  10. OUTCOME OF LOCKING PLATES IN DISTAL TIBIA FRACTURES TREATMENT

    Directory of Open Access Journals (Sweden)

    Lokesh

    2016-05-01

    (22% 4 patients for which secondary surgery with bone grafting procedure was done after 4 months. According to AOFAS, 7 we scored the functional outcome of the patients after 5 months of injury. We had 23% of excellent result, 30.4% good and 46% fair with plate. CONCLUSION Locking anatomical plates are a boon and have started a new era in orthopaedic surgery in fixation with articular fractures. But due to lack of locking plate principle it is again cumbersome. Locking plates give relative stability for fracture and need as much as possible anatomical reduction of articular margins unlike in nail where we can do dynamisation if fracture going for delayed union in locking plates is not possible, hence doing as much as possible fracture alignment and then stabilising the fracture with screws is recommended.

  11. Study on Unified Chaotic System-Based Wind Turbine Blade Fault Diagnostic System

    Science.gov (United States)

    Kuo, Ying-Che; Hsieh, Chin-Tsung; Yau, Her-Terng; Li, Yu-Chung

    At present, vibration signals are processed and analyzed mostly in the frequency domain. The spectrum clearly shows the signal structure and the specific characteristic frequency band is analyzed, but the number of calculations required is huge, resulting in delays. Therefore, this study uses the characteristics of a nonlinear system to load the complete vibration signal to the unified chaotic system, applying the dynamic error to analyze the wind turbine vibration signal, and adopting extenics theory for artificial intelligent fault diagnosis of the analysis signal. Hence, a fault diagnostor has been developed for wind turbine rotating blades. This study simulates three wind turbine blade states, namely stress rupture, screw loosening and blade loss, and validates the methods. The experimental results prove that the unified chaotic system used in this paper has a significant effect on vibration signal analysis. Thus, the operating conditions of wind turbines can be quickly known from this fault diagnostic system, and the maintenance schedule can be arranged before the faults worsen, making the management and implementation of wind turbines smoother, so as to reduce many unnecessary costs.

  12. Dual-worm screw compressors; Compresseurs bi-vis

    Energy Technology Data Exchange (ETDEWEB)

    Baleydier, J P [Bitzer France, 69 - Lyon (France)

    1998-12-31

    Low power worm-screw moto-compressors are used in any king of refrigerating machineries and more and more in air conditioning systems. This paper presents the principle of dual-screw moto-compressors: worm-screw technology, role of oil (lubrication, tightness, cooling), compression, internal pressure, power reduction, lubrication, economizer, operation, model selection and accessories. (J.S.)

  13. Dual-worm screw compressors; Compresseurs bi-vis

    Energy Technology Data Exchange (ETDEWEB)

    Baleydier, J.P. [Bitzer France, 69 - Lyon (France)

    1997-12-31

    Low power worm-screw moto-compressors are used in any king of refrigerating machineries and more and more in air conditioning systems. This paper presents the principle of dual-screw moto-compressors: worm-screw technology, role of oil (lubrication, tightness, cooling), compression, internal pressure, power reduction, lubrication, economizer, operation, model selection and accessories. (J.S.)

  14. An automatic mode-locked system for passively mode-locked fiber laser

    Science.gov (United States)

    Li, Sha; Xu, Jun; Chen, Guoliang; Mei, Li; Yi, Bo

    2013-12-01

    This paper designs and implements one kind of automatic mode-locked system. It can adjust a passively mode-locked fiber laser to keep steady mode-locked states automatically. So the unsteadiness of traditional passively mode-locked fiber laser can be avoided. The system transforms optical signals into electrical pulse signals and sends them into MCU after processing. MCU calculates the frequency of the signals and judges the state of the output based on a quick judgment algorithm. A high-speed comparator is used to check the signals and the comparison voltage can be adjusted to improve the measuring accuracy. Then by controlling two polarization controllers at an angle of 45degrees to each other, MCU extrudes the optical fibers to change the polarization until it gets proper mode-locked output. So the system can continuously monitor the output signal and get it back to mode-locked states quickly and automatically. States of the system can be displayed on the LCD and PC. The parameters of the steady mode-locked states can be stored into an EEPROM so that the system will get into mode-locked states immediately next time. Actual experiments showed that, for a 6.238MHz passively mode-locked fiber lasers, the system can get into steady mode-locked states automatically in less than 90s after starting the system. The expected lock time can be reduced to less than 20s after follow up improvements.

  15. Vertical-Screw-Auger Conveyer Feeder

    Science.gov (United States)

    Walton, Otis (Inventor); Vollmer, Hubert J. (Inventor)

    2016-01-01

    A conical feeder is attached to a vertically conveying screw auger. The feeder is equipped with scoops and rotated from the surface to force-feed regolith the auger. Additional scoops are possible by adding a cylindrical section above the conical funnel section. Such then allows the unit to collect material from swaths larger in diameter than the enclosing casing pipe of the screw auger. A third element includes a flexible screw auger. All three can be used in combination in microgravity and zero atmosphere environments to drill and recover a wide area of subsurface regolith and entrained volatiles through a single access point on the surface.

  16. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.

    Science.gov (United States)

    Kandemir, Utku; Augat, Peter; Konowalczyk, Stefanie; Wipf, Felix; von Oldenburg, Geert; Schmidt, Ulf

    2017-08-01

    To investigate whether (1) the type of fixation at the shaft (hybrid vs. locking), (2) the position of the plate (offset vs. contact) and (3) the implant material has a significant effect on (a) construct stiffness and (b) fatigue life in a distal femur extraarticular comminuted fracture model using the same design of distal femur periarticular locking plate. An extraarticular severely comminuted distal femoral fracture pattern (OTA/AO 33-A3) was simulated using artificial bone substitutes. Ten-hole distal lateral femur locking plates were used for fixation per the recommended surgical technique. At the distal metaphyseal fragment, all possible locking screws were placed. For the proximal diaphyseal fragment, different types of screws were used to create 4 different fixation constructs: (1) stainless steel hybrid (SSH), (2) stainless steel locked (SSL), (3) titanium locked (TiL), and (4) stainless steel locked with 5-mm offset at the diaphysis (SSLO). Six specimens of each construct configuration were tested. First, each specimen was nondestructively loaded axially to determine the stiffness. Then, each specimen was cyclically loaded with increasing load levels until failure. Construct Stiffness: The fixation construct with a stainless steel plate and hybrid fixation (SSH) had the highest stiffness followed by the construct with a stainless steel plate and locking screws (SSL) and were not statistically different from each other. Offset placement (SSLO) and using a titanium implant (TiL) significantly reduced construct stiffness. Fatigue Failure: The stainless steel with hybrid fixation group (SSH) withstood the most number of cycles to failure and higher loads, followed by the stainless steel plate and locking screw group (SSL), stainless steel plate with locking screws and offset group (SSLO), and the titanium plate and locking screws group (TiL) consecutively. Offset placement (SSLO) as well as using a titanium implant (TiL) reduced cycles to failure. Using the

  17. Calculating Characteristics of the Screws with Constant And Variable Step

    Directory of Open Access Journals (Sweden)

    B. N. Zotov

    2015-01-01

    Full Text Available This work is devoted to creating a technique for calculating power characteristics of the screws with constant and variable step for the centrifugal pumps. The technique feature is that the reverse currents, which are observed in screws working at low flow, are numerically taken into account. The paper presents a diagram of the stream in the screw with flow to the network Q=0, and the static pressure of the screw in this mode is computed according to reverse current parameters. Maximum flow of screw is determined from the known formulas. When calculating the power characteristics and computing the overall efficiency of the screw, for the first time a volumetric efficiency of the screw is introduced. It is defined as a ratio between the flow into the network and the sum of the reverse current flows and a flow into the network. This approach allowed us to determine the efficiency of the screw over the entire range of flows.A comparison of experimental characteristics of the constant step screw with those of calculated by the proposed technique shows their good agreement.The technique is also used in calculating characteristics of the variable step screws. The variable step screw is considered as a screw consisting of two screws with a smooth transition of the blades from the inlet to the outlet. Screws in which the step at the inlet is less than that of at the outlet as well as screws with the step at the inlet being more than that of at the outlet were investigated. It is shown that a pressure of the screw with zero step and the value of the reverse currents depend only on the parameters of the input section of the screw, and the maximum flow, if the step at the inlet is more than the step at the outlet, is determined by the parameters of the output part of the screw. Otherwise, the maximum flow is determined a little bit differently.The paper compares experimental characteristics with characteristics calculated by the technique for variable step

  18. A Novel Pedicle Screw with Mobile Connection: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Yasuaki Tokuhashi

    2014-01-01

    Full Text Available To prevent adjacent disc problems after spinal fusion, a pedicle screw with a mobile junction between the head and threaded shaft was newly developed. The threaded shaft of the screw has 10 degrees mobility in all directions, but its structure is to prevent abnormal translation and tilting. This screw was evaluated as follows: (1 endurance test: 106 times rotational stress was applied; (2 biological reactions: novel screws with a mobile head and conventional screws with a fixed head were inserted into the bilateral pedicles of the L3, L4, and L5 in two mini pigs with combination. Eight months after surgery, vertebral units with the screw rod constructs were collected. After CT scan, the soft and bony tissues around the screws were examined grossly and histologically. As a result, none of the screws broke during the endurance test stressing. The mean amount of abrasion wear was 0.0338 g. In the resected mini pig section, though zygapophyseal joints between fixed-head screws showed bony union, the amount of callus in the zygapophyseal joints connected with mobile-head screws was small, and joint space was confirmed by CT. No metalloses were noted around any of the screws. Novel screws were suggested to be highly durable and histologically safe.

  19. Minimally Invasive Technique for PMMA Augmentation of Fenestrated Screws

    Directory of Open Access Journals (Sweden)

    Jan-Helge Klingler

    2015-01-01

    Full Text Available Purpose. To describe the minimally invasive technique for cement augmentation of cannulated and fenestrated screws using an injection cannula as well as to report its safety and efficacy. Methods. A total of 157 cannulated and fenestrated pedicle screws had been cement-augmented during minimally invasive posterior screw-rod spondylodesis in 35 patients from January to December 2012. Retrospective evaluation of cement extravasation and screw loosening was carried out in postoperative plain radiographs and thin-sliced triplanar computed tomography scans. Results. Twenty-seven, largely prevertebral cement extravasations were detected in 157 screws (17.2%. None of the cement extravasations was causing a clinical sequela like a new neurological deficit. One screw loosening was noted (0.6% after a mean follow-up of 12.8 months. We observed no cementation-associated complication like pulmonary embolism or hemodynamic insufficiency. Conclusions. The presented minimally invasive cement augmentation technique using an injection cannula facilitates convenient and safe cement delivery through polyaxial cannulated and fenestrated screws during minimally invasive screw-rod spondylodesis. Nevertheless, the optimal injection technique and design of fenestrated screws have yet to be identified. This trial is registered with German Clinical Trials DRKS00006726.

  20. Insertion profiles of 4 headless compression screws.

    Science.gov (United States)

    Hart, Adam; Harvey, Edward J; Lefebvre, Louis-Philippe; Barthelat, Francois; Rabiei, Reza; Martineau, Paul A

    2013-09-01

    In practice, the surgeon must rely on screw position (insertion depth) and tactile feedback from the screwdriver (insertion torque) to gauge compression. In this study, we identified the relationship between interfragmentary compression and these 2 factors. The Acutrak Standard, Acutrak Mini, Synthes 3.0, and Herbert-Whipple implants were tested using a polyurethane foam scaphoid model. A specialized testing jig simultaneously measured compression force, insertion torque, and insertion depth at half-screw-turn intervals until failure occurred. The peak compression occurs at an insertion depth of -3.1 mm, -2.8 mm, 0.9 mm, and 1.5 mm for the Acutrak Mini, Acutrak Standard, Herbert-Whipple, and Synthes screws respectively (insertion depth is positive when the screw is proud above the bone and negative when buried). The compression and insertion torque at a depth of -2 mm were found to be 113 ± 18 N and 0.348 ± 0.052 Nm for the Acutrak Standard, 104 ± 15 N and 0.175 ± 0.008 Nm for the Acutrak Mini, 78 ± 9 N and 0.245 ± 0.006 Nm for the Herbert-Whipple, and 67 ± 2N, 0.233 ± 0.010 Nm for the Synthes headless compression screws. All 4 screws generated a sizable amount of compression (> 60 N) over a wide range of insertion depths. The compression at the commonly recommended insertion depth of -2 mm was not significantly different between screws; thus, implant selection should not be based on compression profile alone. Conically shaped screws (Acutrak) generated their peak compression when they were fully buried in the foam whereas the shanked screws (Synthes and Herbert-Whipple) reached peak compression before they were fully inserted. Because insertion torque correlated poorly with compression, surgeons should avoid using tactile judgment of torque as a proxy for compression. Knowledge of the insertion profile may improve our understanding of the implants, provide a better basis for comparing screws, and enable the surgeon to optimize compression. Copyright

  1. SURGICAL MANAGEMENT OF TRAUMATIC MANUBRIO-STERNAL DISLOCATION WITH LOCKING COMPRESSION PLATE; A CASE REPORT AND REVIEW OF LITERATURE

    Directory of Open Access Journals (Sweden)

    FAREED AHMED SHAIKH

    2017-05-01

    Full Text Available Background: Manubriosternal joint dislocation as a result of trauma is rare with only few case reports published in literature. Materials that have been used for fixation of displaced manubriosternal joint are steel wires, polydioxanone ropes, and plates with screws. Case: We present a case of manubriosternal dislocation in which fixation was done with locking compression plate. This is a case of 32 years old lady with history of road traffic accident, car ran over her chest. She had bilateral lung contusions with multiple rib fractures on right side and manubriosternal joint dislocation of type-I. Patient was initially stabilized in high dependency unit, and once her contusions got better, she underwent fixation of her manubriosternal dislocation with locking compression plate. Post-operatively she remained pain free and was discharged home. Conclusion: This case is an important addition to literature regarding options that can be used for fixation of manubriosternal joint dislocation.

  2. Ball Screw Actuator Including a Stop with an Integral Guide

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Perek, John (Inventor); Geck, Kellan (Inventor)

    2015-01-01

    An actuator includes a housing assembly, a ball nut, a ball screw, and a ball screw stop. The ball nut is rotationally mounted in the housing assembly, is adapted to receive an input torque, and is configured, upon receipt thereof, to rotate and supply a drive force. The ball screw is mounted within the housing assembly and extends through the ball nut. The ball screw has a first end and a second end, and is coupled to receive the drive force from the ball nut. The ball screw is configured, upon receipt of the drive force, to selectively translate between a stow position and a deploy position. The ball screw stop is mounted on the ball screw to translate therewith and is configured to at selectively engage the housing assembly while the ball screw is translating, and engage the ball nut when the ball screw is in the deploy position.

  3. Percutaneous locking plates for fractures of the distal tibia: our experience and a review of the literature.

    Science.gov (United States)

    Ahmad, Mudussar Abrar; Sivaraman, Alagappan; Zia, Ahmed; Rai, Amarjit; Patel, Amratlal D

    2012-02-01

    Distal tibial metaphyseal fractures pose many complexities. This study assessed the outcomes of distal tibial fractures treated with medial locking plates. Eighteen patients were selected based on the fracture pattern and classified using the AO classification and stabilized with an AO medial tibial locking plate. Time to fracture union, complications, and outcomes were assessed with the American Orthopedic Foot and Ankle Society Ankle score at 12 months. Sixteen of the 18 patients achieved fracture union, with 1 patient lost to follow-up. Twelve fractures united within 24 weeks, with an average union time of 23.1 weeks. Three delayed unions, two at 28 weeks and one at 56 weeks. The average time to union was 32 weeks in the smokers and 15.3 weeks in the nonsmokers. Five of the 18 patients (27%) developed complications. One superficial wound infection, and one chronic wound infection, resulting in nonunion at 56 weeks, requiring revision. Two patients required plate removal, one after sustaining an open fracture at the proximal end of the plate 6 months after surgery (postfracture union)and the other for painful hardware. One patient had implant failure of three proximal diaphyseal locking screws at the screwhead/neck junction, but successful fracture union. The average American Orthopedic Foot and Ankle Society ankle score was 88.8 overall, and 92.1 in fractures that united within 24 weeks. Distal tibial locking plates have high fracture union rates, minimum soft tissue complications, and good functional outcomes. The literature shows similar fracture union and complication rates in locking and nonlocking plates. Copyright © 2012 by Lippincott Williams & Wilkins

  4. Advantage and limitations of a minimally-invasive approach and early weight bearing in the treatment of tibial shaft fractures with locking plates.

    Science.gov (United States)

    Adam, P; Bonnomet, F; Ehlinger, M

    2012-09-01

    Intramedullary nailing is a common method of treating tibial shaft fractures. However, precise control of reduction at the proximal and distal quarters is difficult to achieve. The purpose of this study was to assess the results of plating using locking screws and the feasibility of a minimally-invasive approach. All patients with tibial shaft fracture treated by means of locking plates from January 2004 to October 2006. Thirty-two fractures were treated in 32 patients with a mean age of 43.8 years. Internal fixation with a locking plate and screw construct, using a minimally-invasive or standard approach. Surgical approach, time to weight bearing, complications and their type, time to bone union, alignment in the frontal and sagittal planes on anteroposterior and lateral radiographs. The minimally-invasive approach was performed in 28 cases and immediate full weight bearing allowed in 25 cases. At a mean follow-up of 27 months, two patients had died and two patients were lost to follow-up. The mean time to bone union was 9.1 weeks. Four cases had a complicated course: one infection, one compartment syndrome, one hardware breakage and one pseudarthrosis. Six cases ended up with valgus malunion exceeding 5° in the frontal plane, already present at the time of surgery. Where a minimally-invasive approach can be performed, immediate pain-free weight bearing can be allowed without further displacement at follow-up. The observed rate of malunion underlines the need for adequate reduction and shows that the rationale for success does not solely depend on the plate anatomic design but also on the skills of the operating surgeon. Level I university regional hospital Cohort study. Copyright © 2012. Published by Elsevier Masson SAS.

  5. Ball Screw Actuator Including an Axial Soft Stop

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Forrest, Steven Talbert (Inventor); Abel, Steve (Inventor); Woessner, George (Inventor); Hanlon, Casey (Inventor)

    2016-01-01

    An actuator includes an actuator housing, a ball screw, and an axial soft stop assembly. The ball screw extends through the actuator housing and has a first end and a second end. The ball screw is coupled to receive a drive force and is configured, upon receipt of the drive force, to selectively move in a retract direction and an extend direction. The axial soft stop assembly is disposed within the actuator housing. The axial soft stop assembly is configured to be selectively engaged by the ball screw and, upon being engaged thereby, to translate, with compliance, a predetermined distance in the extend direction, and to prevent further movement of the ball screw upon translating the predetermined distance.

  6. Interband optical pulse injection locking of quantum dot mode-locked semiconductor laser.

    Science.gov (United States)

    Kim, Jimyung; Delfyett, Peter J

    2008-07-21

    We experimentally demonstrate optical clock recovery from quantum dot mode-locked semiconductor lasers by interband optical pulse injection locking. The passively mode-locked slave laser oscillating on the ground state or the first excited state transition is locked through the injection of optical pulses generated via the opposite transition bands, i.e. the first excited state or the ground state transition from the hybridly mode-locked master laser, respectively. When an optical pulse train generated via the first excited state from the master laser is injected to the slave laser oscillating via ground state, the slave laser shows an asymmetric locking bandwidth around the nominal repetition rate of the slave laser. In the reverse injection case of, i.e. the ground state (master laser) to the first excited state (slave laser), the slave laser does not lock even though both lasers oscillate at the same cavity frequency. In this case, the slave laser only locks to higher injection rates as compared to its own nominal repetition rate, and also shows a large locking bandwidth of 6.7 MHz.

  7. Unified communications

    OpenAIRE

    Kravos, Urban

    2011-01-01

    In the modern business world, communication are becoming more and more complex. As a solution to this problem unified communications occurred. Using a single communication approach unified communications are the integration of various communication technologies (eg, telephony, unified messaging, audio, video and web conferencing and collaboration tools). Unified Messaging, which represents only part of the unified communications means the integration of different non real time communication t...

  8. A Biomechanical Analysis of 2 Constructs for Metacarpal Spiral Fracture Fixation in a Cadaver Model: 2 Large Screws Versus 3 Small Screws.

    Science.gov (United States)

    Eu-Jin Cheah, Andre; Behn, Anthony W; Comer, Garet; Yao, Jeffrey

    2017-12-01

    Surgeons confronted with a long spiral metacarpal fracture may choose to fix it solely with lagged screws. A biomechanical analysis of a metacarpal spiral fracture model was performed to determine whether 3 1.5-mm screws or 2 2.0-mm screws provided more stability during bending and torsional loading. Second and third metacarpals were harvested from 12 matched pairs of fresh-frozen cadaveric hands and spiral fractures were created. One specimen from each matched pair was fixed with 2 2.0-mm lagged screws whereas the other was fixed with 3 1.5-mm lagged screws. Nine pairs underwent combined cyclic cantilever bending and axial compressive loading followed by loading to failure. Nine additional pairs were subjected to cyclic external rotation while under a constant axial compressive load and were subsequently externally rotated to failure under a constant axial compressive load. Paired t tests were used to compare cyclic creep, stiffness, displacement, rotation, and peak load levels. Average failure torque for all specimens was 7.2 ± 1.7 Nm. In cyclic torsional testing, the group with 2 screws exhibited significantly less rotational creep than the one with 3 screws. A single specimen in the group with 2 screws failed before cyclic bending tests were completed. No other significant differences were found between test groups during torsional or bending tests. Both constructs were biomechanically similar except that the construct with 2 screws displayed significantly less loosening during torsional cyclic loading, although the difference was small and may not be clinically meaningful. Because we found no obvious biomechanical advantage to using 3 1.5-mm lagged screws to fix long spiral metacarpal fractures, the time efficiency and decreased implant costs of using 2-2.0 mm lagged screws may be preferred. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  9. Hydraulic screw fastening devices - design, maintenance, operational experience

    International Nuclear Information System (INIS)

    Lachner.

    1976-01-01

    With hydraulic screw fastening devices, pretension values with a maximum deviation of +-2.5% from the rated value can be achieved. This high degree of pretension accuracy is of considerable importance with regard to the safety factor required for the screw connection between reactor vessel head and reactor vessel. The operating rhythm of a nuclear power station with its refuelling art regular intervals makes further demands on the screw fastening device, in particular in connection with the transport of screws and for nuts. The necessary installations extend the screw fastening device into a combination of a high-pressure hydraulic cylinder system with an electrical or pneumoelectrical driving unit and an electrical control unit. Maintenance work is complicated by the large number of identical, highly stressed structural elements in connection with an unfavourable relation operating time/outage time. The problems have been perpetually reduced by close cooperation between the manufacturers and users of screw fastening devices. (orig./AK) [de

  10. Stress corrosion cracking lifetime prediction of spring screw

    International Nuclear Information System (INIS)

    Koh, S. K.; Ryu, C. H.

    2004-01-01

    A lifetime prediction of holddown spring screw in nuclear fuel assembly was performed using fracture mechanics approach. The spring screw was designed such that it was capable of sustaining the loads imposed by the initial tensile preload and operational loads. In order to investigate the cause of failure and to predict the stress corrosion cracking life of the screw, a stress analysis of the top nozzle spring assembly was done using finite element analysis. The elastic-plastic finite element analysis showed that the local stresses at the critical regions of head-shank fillet and thread root significantly exceeded than the yield strength of the screw material, resulting in local plastic deformation. Normalized stress intensity factors for PWSCC life prediction was proposed. Primary water stress corrosion cracking life of the Inconel 600 screw was predicted by using integration of the Scott model and resulted in 1.78 years, which was fairly close to the actual service life of the holddown spring screw

  11. Magnesium Alloys as a Biomaterial for Degradable Craniofacial Screws

    Science.gov (United States)

    Henderson, Sarah E.; Verdelis, Konstantinos; Maiti, Spandan; Pal, Siladitya; Chung, William L.; Chou, Da-Tren; Kumta, Prashant N.; Almarza, Alejandro J.

    2014-01-01

    Recently, magnesium (Mg) alloys have received significant attention as a potential biomaterial for degradable implants, and this study was directed at evaluating the suitability of Mg for craniofacial bone screws. The objective was to implant screws fabricated from commercially available Mg-alloys (pure Mg and AZ31) in-vivo in a rabbit mandible. First, Mg-alloy screws were compared to stainless steel screws in an in-vitro pull-out test and determined to have a similar holding strength (~40N). A finite element model of the screw was created using the pull-out test data, and the model can be used for future Mg-alloy screw design. Then, Mg-alloy screws were implanted for 4, 8, and 12 weeks, with two controls of an osteotomy site (hole) with no implant and a stainless steel screw implanted for 12 weeks. MicroCT (computed tomography) was used to assess bone remodeling and Mg-alloy degradation, both visually and qualitatively through volume fraction measurements for all time points. Histologic analysis was also completed for the Mg-alloys at 12 weeks. The results showed that craniofacial bone remodeling occurred around both Mg-alloy screw types. Pure Mg had a different degradation profile than AZ31, however bone growth occurred around both screw types. The degradation rate of both Mg-alloy screw types in the bone marrow space and the muscle were faster than in the cortical bone space at 12 weeks. Furthermore, it was shown that by alloying Mg, the degradation profile could be changed. These results indicate the promise of using Mg-alloys for craniofacial applications. PMID:24384125

  12. Tightening techniques for the retaining screws of universal abutment

    Directory of Open Access Journals (Sweden)

    Alexandre Wittcinski REGALIN

    Full Text Available Abstract Purpose This study evaluated the torque maintenance of universal abutment retaining screws using different tightening techniques, and coated or uncoated screws. Material and method The screws were tightened to implants as following: Control – 32 Ncm torque; H20 – holding 32 Ncm torque for 20 s; R – 32 Ncm torque, repeated after 10 min (retorque; and H20+R – combining the two tightening techniques. Titanium and coated screws were also evaluated. Result Statistical analysis showed higher maintained torque for titanium screws (p<0.001. The H20+R technique showed the highest maintained torque (p=0.003, but the H20 technique’s maintained torque was similar. Conclusion Titanium screws associating the two tightening techniques can improve maintained torque.

  13. Supraglenoid tubercle fractures repair with transverse locking compression plates in 4 horses.

    Science.gov (United States)

    Ahern, B J; Bayliss, I P M; Zedler, S T; Getman, L M; Richardson, D W

    2017-05-01

    To report on a series of 4 horses with supraglenoid tubercle fractures repaired with locking compression plates. Case series. Four horses ranging in age from 6 weeks to 20 months and weighing from 121 to 425 kg with supraglenoid tubercle fractures of 1 day to 6 weeks in duration. Supraglenoid tubercle fractures were reduced and stabilized with transversely positioned locking compression plate(s) with and without additional tension band wiring. All fractures reached bony union. Two postoperative surgical site infections were managed with drainage and antibiotherapy. Three of the 4 horses continued onto athletic careers including flat racing, dressage, and hunter/jumper competition. The remaining horse was lame for a prolonged period, but was sound at 4 years. The application of one or two, transversely positioned LCPs should be considered for the repair of SGT fractures because of the relative ease of the technique, and its elimination of a biceps brachii tenotomy. All screws can be inserted in a lateral to medial direction without transection or drill penetration of the biceps brachii tendon. SGT fractures of various durations can be repaired in a wide range of horses with transversely positioned LCPs, and allow return to athletic function. © 2017 The American College of Veterinary Surgeons.

  14. Double pass locking and spatial mode locking for gravitational wave detectors

    CERN Document Server

    Cusack, B J; Slagmolen, B; Vine, G D; Gray, M B; McClelland, D E

    2002-01-01

    We present novel techniques for overcoming problems relating to the use of high-power lasers in mode cleaner cavities for second generation laser interferometric gravitational wave detectors. Rearranging the optical components into a double pass locking regime can help to protect locking detectors from damage. Modulator thermal lensing can be avoided by using a modulation-free technique such as tilt locking, or its recently developed cousin, flip locking.

  15. Do screws and screw holes affect osteolysis in cementless cups using highly crosslinked polyethylene? A 7 to 10-year follow-up case-control study.

    Science.gov (United States)

    Taniguchi, N; Jinno, T; Takada, R; Koga, D; Ando, T; Okawa, A; Haro, H

    2018-05-01

    The use of screws and the presence of screw holes may cause acetabular osteolysis and implant loosening in cementless total hip arthroplasty (THA) using conventional polyethylene. In contrast, this issue is not fully understood using highly crosslinked polyethylene (HXLPE), particularly in large comparative study. Therefore, we performed a case-control study to assess the influence of screw usage and screw holes on: (1) implant fixation and osteolysis and (2) polyethylene steady-state wear rate, using cases with HXLPE liners followed up for 7-10 years postoperatively. The screw usage and screw holes adversely affect the implant fixation and incidence of wear-related osteolysis in THA with HXLPE. We reviewed 209 primary cementless THAs performed with 26-mm cobalt-chromium heads on HXLPE liners. To compare the effects of the use of screws and the presence of screw holes, the following groups were established: (1) with-screw (n=140); (2) without-screw (n=69); (3) no-hole (n=27) and (4) group in which a cup with screw holes, but no screw was used (n=42). Two adjunct groups (no-hole cups excluded) were established to compare the differences in the two types of HXLPE: (5) remelted group (n=100) and (6) annealed group (n=82). Implant stability and osteolysis were evaluated by plain radiography and computed tomography. The wear rate from 1 year to the final evaluation was measured using plain X-rays and PolyWare Digital software. All cups and stems achieved bony fixation. On CT-scan, no acetabular osteolysis was found, but there were 3 cases with a small area of femoral osteolysis. The mean steady-state wear rate of each group was (1) 0.031±0.022, (2) 0.033±0.035, (3) 0.031±0.024, (4) 0.029±0.018, (5) 0.030±0.018 and (6) 0.034±0.023mm/year, respectively. A comparison of the effects of screw usage or screw holes found no significant between-group differences in the implant stability, prevalence of osteolysis [no acetabular osteolysis and 3/209 at femoral side (1

  16. Twin screw wet granulation: Binder delivery.

    Science.gov (United States)

    Saleh, Mohammed F; Dhenge, Ranjit M; Cartwright, James J; Hounslow, Michael J; Salman, Agba D

    2015-06-20

    The effects of three ways of binder delivery into the twin screw granulator (TSG) on the residence time, torque, properties of granules (size, shape, strength) and binder distribution were studied. The binder distribution was visualised through the transparent barrel using high speed imaging as well as quantified using offline technique. Furthermore, the effect of binder delivery and the change of screw configuration (conveying elements only and conveying elements with kneading elements) on the surface velocity of granules across the screw channel were investigated using particle image velocimetry (PIV). The binder was delivered in three ways; all solid binder incorporated with powder mixture, 50% of solid binder mixed with powder mixture and 50% mixed with water, all the solid binder dissolved in water. Incorporation of all solid binder with powder mixture resulted in the relatively longer residence time and higher torque, narrower granule size distribution, more spherical granules, weaker big-sized granules, stronger small-sized granules and better binder distribution compared to that in other two ways. The surface velocity of granules showed variation from one screw to another as a result of uneven liquid distribution as well as shown a reduction while introducing the kneading elements into the screw configuration. Copyright © 2015. Published by Elsevier B.V.

  17. Biomechanical comparison of 3.0 mm headless compression screw and 3.5 mm cortical bone screw in a canine humeral condylar fracture model.

    Science.gov (United States)

    Gonsalves, Mishka N; Jankovits, Daniel A; Huber, Michael L; Strom, Adam M; Garcia, Tanya C; Stover, Susan M

    2016-09-20

    To compare the biomechanical properties of simulated humeral condylar fractures reduced with one of two screw fixation methods: 3.0 mm headless compression screw (HCS) or 3.5 mm cortical bone screw (CBS) placed in lag fashion. Bilateral humeri were collected from nine canine cadavers. Standardized osteotomies were stabilized with 3.0 mm HCS in one limb and 3.5 mm CBS in the contralateral limb. Condylar fragments were loaded to walk, trot, and failure loads while measuring construct properties and condylar fragment motion. The 3.5 mm CBS-stabilized constructs were 36% stiffer than 3.0 mm HCS-stabilized constructs, but differences were not apparent in quality of fracture reduction nor in yield loads, which exceeded expected physiological loads during rehabilitation. Small residual fragment displacements were not different between CBS and HCS screws. Small fragment rotation was not significantly different between screws, but was weakly correlated with moment arm length (R² = 0.25). A CBS screw placed in lag fashion provides stiffer fixation than an HCS screw, although both screws provide similar anatomical reduction and yield strength to condylar fracture fixation in adult canine humeri.

  18. Mathematical modeling and design parameters of crushing machines with variable-pitch helix of the screw

    Directory of Open Access Journals (Sweden)

    Pelenko V. V.

    2017-11-01

    Full Text Available From the point of view of the effectiveness of the top cutting unit, the helix angle in the end portion of the screw is the most important and characteristic parameter, as it determines the pressure of the meat material in the zone of interaction of a knife and grate. The importance of solving the problem of mathematical modeling of geometry is due to the need to address the problem of minimizing the reverse flow of the food material when injecting into the cutting zone, as the specified effect of "locking" significantly reduces the performance of the transfer process, increases energy consumption of the equipment and entails the deterioration of the quality of the raw materials output. The problem of determining the length of the helix variable pitch for screw chopper food materials has been formulated and solved by methods of differential geometry. The task of correct description of the law of changing the angle of helix inclination along its length has been defined in this case as a key to provide the required dependence of this angle tangent on the angle of the radius-vector of the circle. It has been taken into account that the reduction in the pitch of the screw in the direction of the product delivery should occur at a decreasing rate. The parametric equation of the helix has been written in the form of three functional dependencies of the corresponding cylindrical coordinates. Based on the wide range analysis and significant number of models of tops from different manufacturers the boundaries of possible changes in the angles of inclination of the helical line of the first and last turns of the screw have been identified. The auger screw length is determined mathematically in the form of an analytical relationship and both as a function of the variable angle of its rise, and as a function of the rotation angle of the radius-vector of the circle generatrix, which makes it possible to expand the design possibilities of this node. Along

  19. Development of structural schemes of parallel structure manipulators using screw calculus

    Science.gov (United States)

    Rashoyan, G. V.; Shalyukhin, K. A.; Gaponenko, EV

    2018-03-01

    The paper considers the approach to the structural analysis and synthesis of parallel structure robots based on the mathematical apparatus of groups of screws and on a concept of reciprocity of screws. The results are depicted of synthesis of parallel structure robots with different numbers of degrees of freedom, corresponding to the different groups of screws. Power screws are applied with this aim, based on the principle of static-kinematic analogy; the power screws are similar to the orts of axes of not driven kinematic pairs of a corresponding connecting chain. Accordingly, kinematic screws of the outlet chain of a robot are simultaneously determined which are reciprocal to power screws of kinematic sub-chains. Solution of certain synthesis problems is illustrated with practical applications. Closed groups of screws can have eight types. The three-membered groups of screws are of greatest significance, as well as four-membered screw groups [1] and six-membered screw groups. Three-membered screw groups correspond to progressively guiding mechanisms, to spherical mechanisms, and to planar mechanisms. The four-membered group corresponds to the motion of the SCARA robot. The six-membered group includes all possible motions. From the works of A.P. Kotelnikov, F.M. Dimentberg, it is known that closed fifth-order screw groups do not exist. The article presents examples of the mechanisms corresponding to the given groups.

  20. Automatic NMR field-frequency lock-pulsed phase locked loop approach.

    Science.gov (United States)

    Kan, S; Gonord, P; Fan, M; Sauzade, M; Courtieu, J

    1978-06-01

    A self-contained deuterium frequency-field lock scheme for a high-resolution NMR spectrometer is described. It is based on phase locked loop techniques in which the free induction decay signal behaves as a voltage-controlled oscillator. By pulsing the spins at an offset frequency of a few hundred hertz and using a digital phase-frequency discriminator this method not only eliminates the usual phase, rf power, offset adjustments needed in conventional lock systems but also possesses the automatic pull-in characteristics that dispense with the use of field sweeps to locate the NMR line prior to closure of the lock loop.

  1. CT provides precise size assessment of implanted titanium alloy pedicle screws.

    Science.gov (United States)

    Elliott, Michael J; Slakey, Joseph B

    2014-05-01

    After performing instrumented spinal fusion with pedicle screws, postoperative imaging using CT to assess screw position may be necessary. Stainless steel implants produce significant metal artifact on CT, and the degree of distortion is at least partially dependent on the cross-sectional area of the implanted device. If the same effect occurs with titanium alloy implants, ability to precisely measure proximity of screws to adjacent structures may be adversely affected as screw size increases. We therefore asked whether (1) CT provides precise measurements of true screw widths; and (2) precision degrades based on the size of the titanium implant imaged. CT scans performed on 20 patients after instrumented spinal fusion for scoliosis were reviewed. The sizes of 151 titanium alloy pedicle screws were measured and compared with known screw size. The amount of metal bloom artifact was determined for each of the four screw sizes. ANOVA with Tukey's post hoc test were performed to evaluate differences in scatter, and Spearman's rho coefficient was used to measure relationship between screw size and scatter. All screws measured larger than their known size, but even with larger 7-mm screws the size differential was less than 1 mm. The four different screw sizes produced scatter amounts that were different from each other (p titanium alloy pedicle screws produces minimal artifact, thus making this the preferred imaging modality to assess screw position after surgery. Although the amount of artifact increases with the volume of titanium present, the degree of distortion is minimal and is usually less than 1 mm.

  2. Fate of the syndesmotic screw--Search for a prudent solution.

    Science.gov (United States)

    Kaftandziev, Igor; Spasov, Marko; Trpeski, Simon; Zafirova-Ivanovska, Beti; Bakota, Bore

    2015-11-01

    Ankle fractures are common injuries. Since the recognition of the importance of syndesmotic injury in ankle fractures, much of the scientific work has been focused on concomitant syndesmotic injury. Despite the invention of novel devices for restoration and maintenance of the congruent syndesmosis following syndesmotic injury, the metallic syndesmotic screw is still considered to be the "gold standard". The aim of this study was to compare the clinical results in patients who retained the syndesmosis screw with those in whom the screw was removed following open reduction and internal fixation of the malleolar fracture associated with syndesmosis disruption. This was a retrospective study of 82 patients. Minimum follow-up was 12 months. Clinical evaluation included American Orthopaedic Foot and Ankle Society (AOFAS) score and Visual Analogue Scale (VAS) for patient general satisfaction. The condition of the screw (removed, intact or broken), presence of radiolucency around the syndesmotic screw and the tibiofibular clear space were recorded using final follow-up radiographs. Three cortices were engaged in 66 patients (80%) and quadricortical fixation was performed in the remaining 16 patients (20%). The number of engaged cortices did not correlate with the clinical outcome and screw fracture. A single syndesmotic screw was used in 71 patients (86%. The mean AOFAS score in the group with intact screw (I) was 83; the scores in the group with broken screw (B) and removed screw (R) were 92.5 and 85.5, respectively. There was a statistically significant difference between the three groups: this was due to the difference between groups I and B; the difference between groups I and R and groups B and R were not statistically significant. There were no statistically significant differences in VAS results. There were no statistically significant differences in clinical outcome between the group with the screw retained and the group in which the screw was removed; however, the

  3. Advanced interlocking systems to improve heavy-load-bearing characteristics of flexible intramedullary nailing

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Leopold, E-mail: leopold.berger@tuwien.ac.at [Institute of Building Construction and Technology, TU Wien, Karlsplatz 13/206-4, 1040 Vienna (Austria); Eichler, Johannes [Department of Orthopedics and Orthopedic Surgery, Medical University of Graz, Auenbruggerplatz 5/6, 8036 Graz (Austria); Ryll, E. Jonathan S. [Department of Trauma-, Hand- and Reconstructive Surgery, University Hospital Muenster, Westphalian-Wilhelms University, Muenster (Germany); Fischerauer, Stefan [Department of Traumatology, Medical University of Graz, Auenbruggerplatz 5/6, 8036 Graz (Austria); Raschke, Michael J. [Department of Trauma-, Hand- and Reconstructive Surgery, University Hospital Muenster, Westphalian-Wilhelms University, Muenster (Germany); Kolbitsch, Andreas [Institute of Building Construction and Technology, TU Wien, Karlsplatz 13/206-4, 1040 Vienna (Austria); Castellani, Christoph [Department of Pediatric and Adolescence Surgery, Medical University of Graz, Auenbruggerplatz 34, 8036 Graz (Austria); Weinberg, Annelie-Martina [Department of Orthopedics and Orthopedic Surgery, Medical University of Graz, Auenbruggerplatz 5/6, 8036 Graz (Austria)

    2016-11-01

    Flexible intramedullary nailing (FIN) is a minimally invasive and widespread standard method for osteosynthesis of pediatric long bone fractures. In the case of unstable fractures of the lower extremity, interlocking systems need to be used to prevent axial shortening and subsequent perforation of the nail at its insertion site. In the present study, four different screw-fixed interlocking systems for FINs (Hofer TwinPlug with two 3-mm titanium interlocking screws, Hofer FixPlug with 3-mm titanium interlocking screw, Hofer Plug with 3.5-mm titanium interlocking screw, and Hofer Plug with 3-mm titanium interlocking screw) in comparison with the commonly used Ender stainless steel nails (locked with 3.5-mm screw) were experimentally investigated in cadaveric lamb tibiae, regarding their load characteristics and failure modes in the case of heavy loading. The specimens were subjected to sequential axial cyclic loading of 5000cycles with stepwise increase of the load amplitude until failure. Migration of locking screws and internal damage of bone tissue was quantified by micro-computed tomography (CT) imaging. Ender nails failed on average at a peak load of 800 N, TwinPlugs at 1367 N, FixPlugs at 1222 N, Plugs 3.5mm at 1225 N and Plugs 3.0mm at 971 N. TwinPlugs, FixPlugs, and Plugs 3.5mm failed in a slow manner over several hundred loading cycles, whereas Ender nails and Plugs 3.0mm exhibited abrupt failure without any prior indication. Our results confirm that axial stability of FIN can be further improved by screw-fixed plugs by simultaneously avoiding shortcomings of an eye-locked system, which the Ender nails are. Considering biomechanical results, plug interlocking systems with 3.5-mm screws should be favored over conventional Ender nails and plugs with 3-mm screws. - Highlights: • Locked flexible intramedullary nails in lamb tibiae were cyclically loaded. • Strongly different failure modes of locking systems were detected. • Novel screw-fixed plugs are

  4. Economics of water injected air screw compressor systems

    Science.gov (United States)

    Venu Madhav, K.; Kovačević, A.

    2015-08-01

    There is a growing need for compressed air free of entrained oil to be used in industry. In many cases it can be supplied by oil flooded screw compressors with multi stage filtration systems, or by oil free screw compressors. However, if water injected screw compressors can be made to operate reliably, they could be more efficient and therefore cheaper to operate. Unfortunately, to date, such machines have proved to be insufficiently reliable and not cost effective. This paper describes an investigation carried out to determine the current limitations of water injected screw compressor systems and how these could be overcome in the 15-315 kW power range and delivery pressures of 6-10 bar. Modern rotor profiles and approach to sealing and cooling allow reasonably inexpensive air end design. The prototype of the water injected screw compressor air system was built and tested for performance and reliability. The water injected compressor system was compared with the oil injected and oil free compressor systems of the equivalent size including the economic analysis based on the lifecycle costs. Based on the obtained results, it was concluded that water injected screw compressor systems could be designed to deliver clean air free of oil contamination with a better user value proposition than the oil injected or oil free screw compressor systems over the considered range of operations.

  5. Plate fixation in periprosthetic femur fractures Vancouver type B1-Trochanteric hook plate or subtrochanterical bicortical locking?

    Science.gov (United States)

    Lenz, Mark; Stoffel, Karl; Kielstein, Heike; Mayo, Keith; Hofmann, Gunther O; Gueorguiev, Boyko

    2016-12-01

    Proximal plate fixation in periprosthetic femur fractures can be improved by plate anchorage in the greater trochanter (lateral tension band principle) or bicortical locking screw placement beside the prosthesis stem in an embracement configuration. Both concepts were compared in a biomechanical test using a femoral hook plate (hook) or a locking attachment plate (LAP). After bone mineral density (BMD) measurement in the greater trochanter, six pairs of fresh frozen human femora were assigned to two groups and instrumented with cemented hip endoprostheses. A transverse osteotomy was set distal to the tip of the prosthesis, simulating a Vancouver B1 fracture. Each pair was instrumented using a plate tensioner with either hook or LAP construct. Cyclic testing (2Hz) with physiologic profile and monotonically increasing load was performed until catastrophic failure. Plate stiffness was compared in a four-point-bending-test. Paired student's-t-test was used for statistical evaluation (pTrochanteric fixation is highly BMD dependent and may be restricted to major greater trochanteric involvement requiring stabilization. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Full title: Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures.

    Science.gov (United States)

    Mugnai, Raffaele; Tarallo, Luigi; Capra, Francesco; Catani, Fabio

    2018-05-25

    As the popularity of volar locked plate fixation for distal radius fractures has increased, so have the number and variety of implants, including variations in plate design, the size and angle of the screws, the locking screw mechanism, and the material of the plates. carbon-fiber reinforced polyetheretherketone (CFR-PEEK) plate features similar biomechanical properties to metallic plates, representing, therefore, an optimal alternative for the treatment of distal radius fractures. three different materials-composed plates were evaluated: stainless steel volar lateral column (Zimmer); titanium DVR (Hand Innovations); CFR-PEEK DiPHOS-RM (Lima Corporate). Six plates for each type were implanted in sawbones and an extra-articular rectangular osteotomy was created. Three plates for each material were tested for load to failure and bending stiffness in axial compression. Moreover, 3 constructs for each plate were evaluated after dynamically loading for 6000 cycles of fatigue. the mean bending stiffness pre-fatigue was significantly higher for the stainless steel plate. The titanium plate yielded the higher load to failure both pre and post fatigue. After cyclic loading, the bending stiffness increased by a mean of 24% for the stainless steel plate; 33% for the titanium; and 17% for the CFR-PEEK plate. The mean load to failure post-fatigue increased by a mean of 10% for the stainless steel and 14% for CFR-PEEK plates, whereas it decreased (-16%) for the titanium plate. Statistical analysis between groups reported significant values (p plastic deformation, and lower load to failure. N/A. Copyright © 2018. Published by Elsevier Masson SAS.

  7. Locke and botany.

    Science.gov (United States)

    Anstey, Peter R; Harris, Stephen A

    2006-06-01

    This paper argues that the English philosopher John Locke, who has normally been thought to have had only an amateurish interest in botany, was far more involved in the botanical science of his day than has previously been known. Through the presentation of new evidence deriving from Locke's own herbarium, his manuscript notes, journal and correspondence, it is established that Locke made a modest contribution to early modern botany. It is shown that Locke had close and ongoing relations with the Bobarts, keepers of the Oxford Botanic Garden, and that Locke distributed seeds and plant parts to other botanists, seeds of which the progeny almost certainly ended up in the most important herbaria of the period. Furthermore, it is claimed that the depth of Locke's interest in and practice of botany has a direct bearing on our understanding of his views on the correct method of natural philosophy and on the interpretation of his well known discussion of the nature of species in Book III of his Essay concerning human understanding.

  8. Screw-worm eradication in the Americas - Overview

    International Nuclear Information System (INIS)

    Wyss, John H.

    2000-01-01

    Screw-worms (Cochliomyia hominivorax, Coquerel) are found only in the Americas, and are known, therefore, as the New World Screw-worm (NWS). The larval stages of the fly feed on the living flesh of their host. A screw-worm infestation can kill an adult animal in 7-10 days if not treated. All warm-blooded animals are affected including man. Although screw-worms had long been recognised as a severe pest of animals in the southwestern United States, they had never been detected east of the Mississippi River before 1933. In July 1933, screw-worms were transported on infested cattle to Georgia and became established east of the Mississippi River. Screw-worms spread quickly in the southeastern United States and were able to overwinter in southern Florida. Being new to the region, they were quickly recognised as a severe pest with a tremendous economic impact on livestock production. The livestock owners in the southeastern United States immediately noticed an increase in the number of animal deaths and increased costs of insecticides, veterinary medicines, veterinary services, inspection and handling. At the same time, they observed a decrease in animal weights and in milk production. Due to these observations, the livestock industry in the southeastern United States requested help in controlling screw-worms. Because of these requests, the research community became interested in control and eradication measures for this pest. Early work by Crushing and Patton in 1933 recognised that C. hominivorax was an obligatory animal parasite and different from the secondary blowfly, Cochliomyia macellaria. In 1934, the US Department of Agriculture (USDA), Agricultural Research Service (ARS) opened a research station in Valdosa, Georgia, and E.W. Laake and E.F. Knipling were assigned to work there. In September 1935, R.C. Bushland was hired by ARS to do research related to screw-worms at an ARS Research Laboratory in Dallas, Texas. Melvin and Bushland in 1936 developed artificial

  9. The accuracy and safety of fluoroscopically guided percutaneous pedicle screws in the lumbosacral junction and the lumbar spine: a review of 880 screws.

    Science.gov (United States)

    Chiu, C K; Kwan, M K; Chan, C Y W; Schaefer, C; Hansen-Algenstaedt, N

    2015-08-01

    We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. A total of 880 percutaneous pedicle screws from 203 patients were analysed: 614 screws from 144 European patients and 266 screws from 59 Asian patients. The mean age of the patients was 58.8 years (16 to 91) and there were 103 men and 100 women. The total rate of perforation was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade 3 perforations. The rate of perforation in Europeans was 10.4% and in Asians was 8.6%, with no significant difference between the two (p = 0.42). The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location. ©2015 The British Editorial Society of Bone & Joint Surgery.

  10. Conceptual design of ball-screw type control element drive mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Ho; Kim, Jong In; Huh, Hyung [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-10-01

    In this report, the design features of ball-screw type CEDM with fine-step movement capability are described. The contents of this report are as follows: -Review of Design Requirements for Ball-screw type CEDM -System Description for Ball-screw type CEDM -Design of Ball Bearing and Ball-screw Assembly -Detail Design of Rotary Step Motor -Detail Design of Angular Position Indicator -Materials. The Ball-screw type CEDM described in this report is to be utilized as the starting point for design development of CEDM for SMART. 11 refs., 43 figs., 3 tabs. (Author)

  11. Passage of an Anterior Odontoid Screw through Gastrointestinal Tract.

    Science.gov (United States)

    Leitner, L; Brückmann, C I; Gilg, M M; Bratschitsch, G; Sadoghi, P; Leithner, A; Radl, R

    2017-01-01

    Purpose . Anterior screw fixation has become a popular surgical treatment method for instable odontoid fractures. Screw loosening and migration are a rare, severe complication following anterior odontoid fixation, which can lead to esophagus perforation and requires revision operation. Methods . We report a case of screw loosening and migration after anterior odontoid fixation, which perforated the esophagus and was excreted without complications in a 78-year-old male patient. Results . A ventral dislocated anterior screw perforated through the esophagus after eight years after implantation and was excreted through the gastrointestinal (GI) tract. At a 6-month follow-up after the event the patient was asymptomatic. Conclusion . Extrusion via the GI tract is not safe enough to be considered as a treatment option for loosened screws. Some improvements could be implemented to prevent such an incident. Furthermore, this case is a fine example that recent preoperative imaging is mandatory before revision surgery for screw loosening.

  12. Passage of an Anterior Odontoid Screw through Gastrointestinal Tract

    Directory of Open Access Journals (Sweden)

    L. Leitner

    2017-01-01

    Full Text Available Purpose. Anterior screw fixation has become a popular surgical treatment method for instable odontoid fractures. Screw loosening and migration are a rare, severe complication following anterior odontoid fixation, which can lead to esophagus perforation and requires revision operation. Methods. We report a case of screw loosening and migration after anterior odontoid fixation, which perforated the esophagus and was excreted without complications in a 78-year-old male patient. Results. A ventral dislocated anterior screw perforated through the esophagus after eight years after implantation and was excreted through the gastrointestinal (GI tract. At a 6-month follow-up after the event the patient was asymptomatic. Conclusion. Extrusion via the GI tract is not safe enough to be considered as a treatment option for loosened screws. Some improvements could be implemented to prevent such an incident. Furthermore, this case is a fine example that recent preoperative imaging is mandatory before revision surgery for screw loosening.

  13. Range of motion, sacral screw and rod strain in long posterior spinal constructs: a biomechanical comparison between S2 alar iliac screws with traditional fixation strategies.

    Science.gov (United States)

    Sutterlin, Chester E; Field, Antony; Ferrara, Lisa A; Freeman, Andrew L; Phan, Kevin

    2016-12-01

    S1 screw failure and L5/S1 non-union are issues with long fusions to S1. Improved construct stiffness and S1 screw offloading can help avoid this. S2AI screws have shown to provide similar stiffness to iliac screws when added to L3-S1 constructs. We sought to examine and compare the biomechanical effects on an L2-S1 pedicle screw construct of adding S2AI screws, AxiaLIF, L5-S1 interbody support via transforaminal lumbar interbody fusion (TLIF), and to examine the effect of the addition of cross connectors to each of these constructs. Two S1 screws and one rod with strain gauges (at L5/S1) were used in L2-S1 screw-rod constructs in 7 L1-pelvis specimens (two with low BMD). ROM, S1 screw and rod strain were assessed using a pure-moment flexibility testing protocol. Specimens were tested intact, and then in five instrumentation states consisting of: (I) Pedicle screws (PS) L2-S1; (II) PS + S2AI screws; (III) PS + TLIF L5/S1; (IV) PS + AxiaLIF L5/S1; (V) PS + S2AI + AxiaLIF L5/S1. The five instrumentation conditions were also tested with crosslinks at L2/3 and S1/2. Tests were conducted in flexion-extension, lateral bending and axial torsion with no compressive preload. S2A1 produces reduced S1 screw strain for flexion-extension, lateral bending and axial torsion, as well as reduced rod strain in lateral bending and axial torsion in comparison to AxiaLIF and interbody instrumentation, at the expense of increased rod flexion-extension strain. Cross-connectors may have a role in further reduction of S1 screw and rod strain. From a biomechanical standpoint, the use of the S2AI technique is at least equivalent to traditional iliac screws, but offers lower prominence and ease of assembly compared to conventional sacroiliac stabilization.

  14. Experimental study of pedicle screw stability on low BMD vertebrae

    International Nuclear Information System (INIS)

    Li Qi; Yang Huilin; Tang Tiansi; Wu Yiwei; Wang Yijin

    2005-01-01

    Objective: To conduct biomechanical study of different pedicle screws stability on spinal specimen, discuss the relationship between design parameter of screw, insertion torgue and BMD, establish the theoretical foundation for application of pedicle screw on osteoporotic patients. Methods: Six fixed lumbar cadavers were collected, the effects of design parameter, insertion torque and etc on fixation stability were determined under various BMD by using biomechanical ways. Results: According to in vitro study: (1) There was a significant difference among pullout strength of all screws (P 2 >U 1 >SF 1 >SF 2 >RF. Conclusions: There is a close correlated between type of screw, BMD and stability. The U-type screw displays the best fixation effect on specimen of low BMD. (authors)

  15. Innovation and Lock-in

    DEFF Research Database (Denmark)

    Cantner, Uwe; Vannuccini, Simone

    2016-01-01

    This study focuses on a well-known but yet elusive concept: (technological) lock-in. We summarize what is known about the nature of lock-in and offer a critical view on history-dependent processes based on recent contributions to the literature. We discuss if lock-ins are really inescapable......, especially when innovation is concerned. Also, we address the question if lock-in is a well-defined concept at all. To offer a fresh view on lock-in and to tackle the issues just raised, we employ the replicator dynamics model. By making a parallel between monopolization in the replicator dynamics...... and the occurrence of lock-ins, we show that the convergence of a system to a given outcome can be reversed, under certain conditions. We highlight the need for a more precise demarcation of the conceptual boundaries of lock-in and path dependence, both from the formal and the empirical side, and suggest...

  16. Safety and surgical techniques of C1 lateral mass screws

    International Nuclear Information System (INIS)

    Kubo, Shinichiro; Kuroki, Hiroshi; Hanado, Shoji; Hamanaka, Hideaki; Inomata, Naoki; Kuroki, Shuji; Chosa, Etsuo

    2010-01-01

    The objectives of this study were to evaluate the proper insertion techniques of C1 lateral mass screws. Eighteen consecutive patients were examined after upper cervical fusion using twenty-nine C1 lateral mass screws. Screws were placed by three different techniques; Goel's technique (4), Tan's technique (20), Notching technique (5). Pre and post-operative CT scans with multiplanar reconstruction were used to detect cortical breaches and direction of screws. No transverse foramen and vertebral groove violation was found in CT scans. Three had breached superior articular facet of the atlas. However, the range of motion (R.O.M) of atlanto-occipital joints had not changed postoperatively. Theses screws were inserted with Tan's technique and two of three were directed medially. It is feasible to safely insert C1 lateral mass screws when correct insertion point and direction are considered preoperatively. However, care should be taken because screws can violate the atlanto-occipital joint especially with Tan's technique. (author)

  17. Comparing the Overhead of Lock-based and Lock-free Implementations of Priority Queues

    DEFF Research Database (Denmark)

    Passas, Stavros; Karlsson, Sven

    2011-01-01

    . In this paper, we compare a lock-free implementation of a priority queue with a lock-based implementation. We perform experiments with processors of different generations and observe large performance differences for lock-free data structures depending on the processor generation. The lock-free implementation...... performs much better on the most recent processor generation. We investigate this performance trend, using a set of micro-benchmarks and show a significant difference in the overhead of atomic operations between processor generations. The lock-free implementation executes approximately three times as many...

  18. Accuracy of pedicle screw placement in patients with Marfan syndrome.

    Science.gov (United States)

    Qiao, Jun; Zhu, Feng; Xu, Leilei; Liu, Zhen; Sun, Xu; Qian, Bangping; Jiang, Qing; Zhu, Zezhang; Qiu, Yong

    2017-03-21

    There is no study concerning safety and accuracy of pedicle screw placement in Marfan syndrome. The objective of this study is to investigate accuracy and safety of pedicle screw placement in scoliosis associated with Marfan syndrome. CT scanning was performed to analyze accuracy of pedicle screw placement. Pedicle perforations were classified as medial, lateral or anterior and categorized to four grades: ≤ 2 mm as Grade 1, 2.1-4.0 mm as Grade 2, 4.1-6.0 mm as Grade 3, ≥6.1 mm as Grade 4. Fully contained screws or with medial wall perforation ≤ 2 mm or with lateral wall perforation ≤ 6 mm and without injury of visceral organs were considered acceptable, otherwise were unacceptable. 976 pedicle screws were placed, 713 screws (73.1%) were fully contained within the cortical boundaries of the pedicle. 924 (94.7%) screws were considered as acceptable, and 52 (5.3%) as unacceptable. The perforation rate was higher using free-hand technique than O-arm navigation technique (30.8% VS. 11.4%, P Marfan syndrome is accuracy and safe. O-arm navigation was an effective modality to ensure the safety and accuracy of screw placement. Special attention should be paid when screws were placed at the lumber spine and the concave side of spine deformity to avoid the higher rate of complications.

  19. Process and remote device for unscrewing and extracting an assembly screw

    International Nuclear Information System (INIS)

    Lagarrigue, F.

    1990-01-01

    The device comprises a C-shaped frame, with two parallel arms and a joining section fixed at one end of a long support, an extraction screw engaged in a hole through one arm and having one end made of a centre punch directed towards the inside of the frame and a remote mean for screwed or unscrewed the extraction screw. A supporting and centering piece can also be fixed to the second branch of the frame. The screw is extracted by exerting a moment about the axis of the screw through the support and frame after tightening the extraction screw. This device can be used particularly for the unscrewing and the extraction of the screw of the springs of a nuclear fuel assembly [fr

  20. Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study.

    Science.gov (United States)

    Huang, Xiaowei; Zhi, Zhongzheng; Yu, Baoqing; Chen, Fancheng

    2015-11-25

    The purpose of this study is to compare the stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture. A three-dimensional (3D) finite element model of the medial tibial plateau fracture (Schatzker type IV fracture) was created. An axial force of 2500 N with a distribution of 60% to the medial compartment was applied to simulate the axial compressive load on an adult knee during single-limb stance. The equivalent von Mises stress, displacement of the model relative to the distal tibia, and displacement of the implants were used as the output measures. The mean stress value of the plate-screw fixation system was 18.78 MPa, which was significantly (P stress value of the triangular fragment in the plate-screw fixation system model was 42.04 MPa, which was higher than that in the screw fixation model (24.18 MPa). But the mean stress of the triangular fractured fragment in the screw fixation model was significantly higher in terms of equivalent von Mises stress (EVMS), x-axis, and z-axis (P < 0.001). This study demonstrated that the load transmission mechanism between plate-screw fixation system and screw fixation system was different and the stability provided by the plate-screw fixation system was superior to the screw fixation system.

  1. Equine ulnar fracture repair with locking compression plates can be associated with inadvertent penetration of the lateral cortex of the radius.

    Science.gov (United States)

    Kuemmerle, Jan M; Kühn, Karolin; Bryner, Marco; Fürst, Anton E

    2013-10-01

    To evaluate if the use of locking head screws (LHS) in the distal holes of a locking compression plate (LCP) applied to the caudal aspect of the ulna to treat equine ulnar fractures is associated with a risk of injury to the lateral cortex of the radius. Controlled laboratory study. Cadaveric equine forelimbs (n = 8 pair). After transverse ulnar osteotomy, osteosynthesis was performed with a narrow 10-13 hole 4.5/5.0 LCP applied to the caudal aspect of each ulna. The distal 3 holes were filled with 4.5 mm cortex screws (CS) in 1 limb (group 1) and with 5.0 mm LHS contralaterally (group 2). CS were inserted in an angle deemed appropriate by the surgeon and LHS were inserted perpendicular to the plate. Implant position and injury to the lateral cortex of the radius were assessed by radiography, CT, and limb dissection. In group 1, injury of the lateral radius cortex did not occur. In group 2, 4 limbs and 6/24 LHS were associated with injury of the lateral radius cortex by penetration of a LHS. This difference was statistically significant. CS were inserted with a mean angle of 17.6° from the sagittal plane in a caudolateral-craniomedial direction. Use of LHS in the distal part of a LCP applied to the caudal aspect of the ulna is associated with a risk of inadvertent injury to the lateral cortex of the radius. © Copyright 2013 by The American College of Veterinary Surgeons.

  2. BIOMECHANICAL EVALUATION OF THE INFLUENCE OF CERVICAL SCREWS TAPPING AND DESIGN.

    Science.gov (United States)

    Silva, Patricia; Rosa, Rodrigo César; Shimano, Antonio Carlos; Albuquerque de Paula, Francisco José; Volpon, José Batista; Aparecido Defino, Helton Luiz

    2009-01-01

    To assess if the screw design (self-drilling/self-tapping) and the pilot hole tapping could affect the insertion torque and screw pullout strength of the screw used in anterior fixation of the cervical spine. Forty self-tapping screws and 20 self-drilling screws were inserted into 10 models of artificial bone and 10 cervical vertebrae of sheep. The studied parameters were the insertion torque and pullout strength. The following groups were created: Group I-self-tapping screw insertion after pilot hole drilling and tapping; Group II-self-tapping screw insertion after pilot hole drilling without tapping; Group III-self-drilling screw insertion without drilling and tapping. In Groups I and II, the pilot hole had 14.0 mm in depth and was made with a 3mmn drill, while tapping was made with a 4mm tap. The insertion torque was measured and the pullout test was performed. The comparison between groups was made considering the mean insertion torque and the maximum mean pullout strength with the variance analysis (ANOVA; p≤ 0.05). Previous drilling and tapping of pilot hole significantly decreased the insertion torque and the pullout strength. The insertion torque and pullout strength of self-drilling screws were significantly higher when compared to self-tapping screws inserted after pilot hole tapping.

  3. Posterior cervical spine arthrodesis with laminar screws. A report of two cases

    International Nuclear Information System (INIS)

    Nakanishi, Kazuo; Tanaka, Masato; Sugimoto, Yoshihisa; Ozaki, Toshifumi

    2007-01-01

    We performed fixation using laminar screws in 2 patients in whom lateral mass screws, pedicle screws or transarticular screws could not be inserted. One was a 56-year-old woman who had anterior atlantoaxial subluxation (AAS). When a guide wire was inserted using an imaging guide, the hole bled massively. We thought the re-insertion of a guide wire or screw would thus increase the risk of vascular injury, so we used laminar screws. The other case was an 18-year-old man who had a hangman fracture. Preoperative magnetic resonance angiography showed occlusion of the left vertebral artery. A laminar screw was inserted into the patent side (i.e., the right side of C2). Cervical pedicle screws are the most biomechanically stable screws. However, their use carries a high risk of neurovascular complications during screw insertion, because the cervical pedicle is small and is adjacent laterally to the vertebral artery, medially to the spinal cord, and vertically to the nerve roots. Lateral mass screws are also reported to involve a risk of neurovascular injuries. The laminar screw method was thus thought to be useful, since arterial injuries could thus be avoided and it could also be used as a salvage modality for the previous misinsertion. (author)

  4. Outdraft at Lock Approach, Tom Bevill Lock and Dam, Alabama: Hydraulic Model Investigation

    National Research Council Canada - National Science Library

    Lynch, Gary

    2001-01-01

    .... The lock is connected to the dam with a 150-ft abutment wall. A strong crosscurrent or outdraft existing in and around the upstream lock entrance causes difficulty for tow traffic navigating the lock...

  5. Modeling and Analyzing the Slipping of the Ball Screw

    Directory of Open Access Journals (Sweden)

    Nannan Xu

    Full Text Available AbstractThis paper aims to set up the ball systematic slipping model and analyze the slipping characteristics caused by different factors for a ball screw operating at high speeds. To investigate the ball screw slipping mechanism, transformed coordinate system should be established firstly. Then it is used to set up mathematical modeling for the ball slipping caused by the three main reasons and the speed of slipping can be calculated. Later, the influence of the contact angle, helix angle and screw diameter for ball screw slipping will be analyzed according to the ball slipping model and slipping speeds equation and the slipping analysis will be obtained. Finally, curve of slipping analysis and that of mechanical efficiency of the ball screw analysis by Lin are compared, which will indirectly verify the correctness of the slipping model. The slipping model and the curve of slipping analysis established in this paper will provide theory basis for reducing slipping and improving the mechanical efficiency of a ball screw operating at high speeds.

  6. 49 CFR 236.338 - Mechanical locking required in accordance with locking sheet and dog chart.

    Science.gov (United States)

    2010-10-01

    ... locking sheet and dog chart. 236.338 Section 236.338 Transportation Other Regulations Relating to... in accordance with locking sheet and dog chart. Mechanical locking shall be in accordance with locking sheet and dog chart currently in effect. ...

  7. Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study.

    Science.gov (United States)

    Kanneganti, Krishna Chaitanya; Vinnakota, Dileep Nag; Pottem, Srinivas Rao; Pulagam, Mahesh

    2018-01-01

    The purpose of this study is to compare the effect of implant-abutment connections, abutment angulations, and screw lengths on screw loosening (SL) of preloaded abutment using three dimensional (3D) finite element analysis. 3D models of implants (conical connection with hex/trilobed connections), abutments (straight/angulated), abutment screws (short/long), and crown and bone were designed using software Parametric Technology Corporation Creo and assembled to form 8 simulations. After discretization, the contact stresses developed for 150 N vertical and 100 N oblique load applications were analyzed, using ABAQUS. By assessing damage initiation and shortest fatigue load on screw threads, the SL for 2.5, 5, and 10 lakh cyclic loads were estimated, using fe-safe program. The obtained values were compared for influence of connection design, abutment angulation, and screw length. In straight abutment models, conical connection showed more damage (14.3%-72.3%) when compared to trilobe (10.1%-65.73%) at 2.5, 5, and 10 lakh cycles for both vertical and oblique loads, whereas in angulated abutments, trilobe (16.1%-76.9%) demonstrated more damage compared to conical (13.5%-70%). Irrespective of the connection type and abutment angulation, short screws showed more percentage of damage compared to long screws. The present study suggests selecting appropriate implant-abutment connection based on the abutment angulation, as well as preferring long screws with more number of threads for effective preload retention by the screws.

  8. A four lumen screwing device for multiparametric brain monitoring.

    Science.gov (United States)

    Feuerstein, T H; Langemann, H; Gratzl, O; Mendelowitsch, A

    2000-01-01

    We describe multiparametric monitoring in severe head trauma using a new screwing device. Our aim was to create a screw which would make the implantation of the probes and thus multiparametric monitoring easier. The new screw allows us to implant 3 probes (microdialysis, Paratrend and an intracranial pressure device) through one burr hole. The screw has four channels, the fourth being for ventricular drainage. We monitored 13 patients with severe head trauma (GCS = 3-8) for up to 7 days. Brain tissue pO2, pCO2, pH, and temperature were measured on-line with the Paratrend 7 machine. The microdialytic parameters glucose, lactate, pyruvate and glutamate were determined semi on-line with a CMA 600 enzymatic analyser. There were no complications in any of the patients that could be ascribed to the screw.

  9. Experiments on screw-pinch plasmas with elongated cross section

    International Nuclear Information System (INIS)

    Lassing, H.W.

    1989-01-01

    In this thesis experiments are described carried out with SPICA II, a toroidal screw-pinch plasma device. this device is the last one in a series of plasma machines of the toroidal screw-pinch differing from its predecessor in its race-track shaped section. In devices of the type toroidal screw-pinch stable confinement is possible of plasmas with larger β values than in a tokamak discharge. In a pinch the plasma is screwed up, during the formation, in such a way that in a relatively small volume a plasma is formated with a high pressure. During the screwing up the plasma is heated by shock heating as well as adiabatic compression. With the modified snowplow model the density and temperature after the formation can be calculated, starting from the initial conditions. When all ions arrive into the plasma column, the density in the column is determined by the volume compression. First purpose of the experiments was to find a stable discharge. Subsequently discharges have been made with a high as possible β in order to investigate at which maximum β it is possible to confine screw-pinch plasmas stably. When these had been found, the nature and importance could be investigated of the processes following which the screw-pinch plasma looses its energy. (author), 75 res.; 95 figs.; 8 tabs

  10. Determination of Screw and Nail Withdrawal Resistance of Some Important Wood Species

    Directory of Open Access Journals (Sweden)

    Alper Aytekin

    2008-04-01

    Full Text Available In this study, screw and nail withdrawal resistance of fir (Abies nordmanniana, oak (Quercus robur L. black pine (Pinus nigra Arnold and Stone pine (Pinus pinea L. wood were determined and compared. The data represent the testing of withdrawal resistance of three types of screws as smart, serrated and conventional and common nails. The specimens were prepared according to TS 6094 standards. The dimensions of the specimens were 5x5x15cm and for all of the directions. Moreover, the specimens were conditioned at ambient room temperature and 65±2% relative humidity. The screws and nails were installed according to ASTM-D 1761 standards. Nail dimensions were 2.5mm diameter and 50 mm length, conventional screws were 4x50mm, serrated screws were 4x45mm and smart screws were 4x50mm. Results show that the maximum screw withdrawal resistance value was found in Stone pine for the serrated screw. There were no significant differences between Stone pine and oak regarding screw withdrawal resistance values. Conventional screw yielded the maximum screw withdrawal resistance value in oak, followed by Stone pine, black pine and fir. Oak wood showed the maximum screw withdrawal resistance value for the smart screw, followed by Stone pine, black pine, and fir. Oak wood showed higher nail withdrawal resistances than softwood species. It was also determined that oak shows the maximum nail withdrawal resistance in all types. The nail withdrawal resistances at the longitudinal direction are lower with respect to radial and tangential directions.

  11. Enhancement of Orthodontic Anchor Screw Stability Under Immediate Loading by Ultraviolet Photofunctionalization Technology.

    Science.gov (United States)

    Takahashi, Maiko; Motoyoshi, Mitsuru; Inaba, Mizuki; Hagiwara, Yoshiyuki; Shimizu, Noriyoshi

    Ultraviolet (UV)-mediated photofunctionalization technology is intended to enhance the osseointegration capability of titanium implants. There are concerns about orthodontic anchor screws loosening under immediate loading protocols in adolescent orthodontic treatment. The purpose of this in vivo study was to evaluate the effects of photofunctionalization on the intrabony stability of orthodontic titanium anchor screws and bone-anchor screw contact under immediate loading in growing rats. Custom-made titanium anchor screws (1.4 mm in diameter and 4.0 mm in length) with or without photofunctionalization pretreatment were placed on the proximal epiphysis of the tibial bone in 6-week-old male Sprague-Dawley rats and were loaded immediately after placement. After 2 weeks of loading, the stability of the anchor screws was evaluated using a Periotest device, and the bone-anchor screw contact ratio (BSC) was assessed by a histomorphometric analysis using field-emission scanning electron microscopy. In the unloaded group, Periotest values (PTVs) were ~25 for UV-untreated screws and 13 for UVtreated screws (P < .01), while in the immediate-loading group, PTVs were 28 for UV-untreated screws and 16 for UV-treated screws (P < .05). Significantly less screw mobility was observed in both UV-treated groups regardless of the loading protocol. The BSC was increased ~1.8 fold for UV-treated screws, compared with UV-untreated screws, regardless of the loading protocol. Photofunctionalization enhanced the intrabony stability of orthodontic anchor screws under immediate loading in growing rats by increasing bone-anchor screw contact.

  12. Probing and Tapping: Are We Inserting Pedicle Screws Correctly?

    Science.gov (United States)

    Prasad, Vishal; Mesfin, Addisu; Lee, Robert; Reigrut, Julie; Schmidt, John

    2016-11-01

    Although there are a significant number of research publications on the topic of bone morphology and the strength of bone, the clinical significance of a failed pedicle screw is often revision surgery and the potential for further postoperative complications; especially in elderly patients with osteoporotic bone. The purpose of this report is to quantify the mechanical strength of the foam-screw interface by assessing probe/pilot hole diameter and tap sizes using statistically relevant sample sizes under highly controlled test conditions. The study consisted of two experiments and used up to three different densities of reference-grade polyurethane foam (ASTM 1839), including 0.16, 0.24, and 0.32 g/cm 3 . All screws and rods were provided by K2M Inc. and screws were inserted to a depth of 25 mm. A series of pilot holes, 1.5, 2.2, 2.7, 3.2, 3.7, 4.2, 5.0, and 6.0 mm in diameter were drilled through the entire depth of the material. A 6.5 × 45-mm pedicle screw was inserted and axially pulled from the material (n = 720). A 3.0-mm pilot hole was drilled and tapped with: no tap, 3.5-, 4.5-, 5.5-, and 6.5-mm taps. A 6.5 × 45-mm pedicle screw was inserted and axially pulled from the material (n = 300). The size of the probe/pilot hole had a nonlinear, parabolic effect on pullout strength. This shape suggests an optimum-sized probe hole for a given size pedicle screw. Too large or too small of a probe hole causes a rapid falloff in pullout strength. The tap data demonstrated that not tapping and undertapping by two or three sizes did not significantly alter the pullout strength of the screws. The data showed an exponential falloff of pullout strength when as tap size increased to the diameter of the screw. In the current study, the data show that an ideal pilot hole size half the diameter of the screw is a starting point. Also, that if tapping was necessary, to use a tap two sizes smaller than the screw being implanted. A similar optimum pilot hole or tap size may be

  13. Air lock

    International Nuclear Information System (INIS)

    Palkovich, P.; Gruber, J.; Madlener, W.

    1974-01-01

    The patent refers to an air lock system preferably for nuclear stations for the transport of heavy loads by means of a trolley on rails. For opening and closing of the air lock parts of the rails are removed, e.g. by a second rail system perpendicular to the main rails. (P.K.)

  14. Economics of water injected air screw compressor systems

    OpenAIRE

    Madhav, K. V.; Kovacevic, A.

    2015-01-01

    There is a growing need for compressed air free of entrained oil to be used in industry. In many cases it can be supplied by oil flooded screw compressors with multi stage filtration systems, or by oil free screw compressors. However, if water injected screw compressors can be made to operate reliably, they could be more efficient and therefore cheaper to operate. Unfortunately, to date, such machines have proved to be insufficiently reliable and not cost effective. This paper describes an in...

  15. Adjacent-segment disease after thoracic pedicle screw fixation.

    Science.gov (United States)

    Agarwal, Nitin; Heary, Robert F; Agarwal, Prateek

    2018-03-01

    OBJECTIVE Pedicle screw fixation is a technique widely used to treat conditions ranging from spine deformity to fracture stabilization. Pedicle screws have been used traditionally in the lumbar spine; however, they are now being used with increasing frequency in the thoracic spine as a more favorable alternative to hooks, wires, or cables. Although safety concerns, such as the incidence of adjacent-segment disease (ASD) after cervical and lumbar fusions, have been reported, such issues in the thoracic spine have yet to be addressed thoroughly. Here, the authors review the literature on ASD after thoracic pedicle screw fixation and report their own experience specifically involving the use of pedicle screws in the thoracic spine. METHODS Select references from online databases, such as PubMed (provided by the US National Library of Medicine at the National Institutes of Health), were used to survey the literature concerning ASD after thoracic pedicle screw fixation. To include the authors' experience at Rutgers New Jersey Medical School, a retrospective review of a prospectively maintained database was performed to determine the incidence of complications over a 13-year period in 123 consecutive adult patients who underwent thoracic pedicle screw fixation. Children, pregnant or lactating women, and prisoners were excluded from the review. By comparing preoperative and postoperative radiographic images, the occurrence of thoracic ASD and disease within the surgical construct was determined. RESULTS Definitive radiographic fusion was detected in 115 (93.5%) patients. Seven incidences of instrumentation failure and 8 lucencies surrounding the screws were observed. One patient was observed to have ASD of the thoracic spine. The mean follow-up duration was 50 months. CONCLUSIONS This long-term radiographic evaluation revealed the use of pedicle screws for thoracic fixation to be an effective stabilization modality. In particular, ASD seems to be less of a problem in the

  16. Positioning of pedicle screws in adolescent idiopathic scoliosis using electromyography

    Directory of Open Access Journals (Sweden)

    Bruno Moreira Gavassi

    2015-06-01

    Full Text Available OBJECTIVE: To analyze the occurrence of poor positioning of pedicle screws inserted with the aid of intraoperative electromyographic stimulation in the treatment of Adolescent Idiopathic Scoliosis (AIS.METHODS: This is a prospective observational study including all patients undergoing surgical treatment for AIS, between March and December 2013 at a single institution. All procedures were monitored by electromyography of the inserted pedicle screws. The position of the screws was evaluated by assessment of postoperative CT and classified according to the specific AIS classification system.RESULTS: Sixteen patients were included in the study, totalizing 281 instrumented pedicles (17.5 per patient. No patient had any neurological deficit or complaint after surgery. In the axial plane, 195 screws were found in ideal position (69.4% while in the sagittal plane, 226 screws were found in ideal position (80.4%. Considering both the axial and the sagittal planes, it was observed that 59.1% (166/281 of the screws did not violate any cortical wall.CONCLUSION: The use of pedicle screws proved to be a safe technique without causing neurological damage in AIS surgeries, even with the occurrence of poor positioning of some implants.

  17. Preoperative CT planning of screw length in arthroscopic Latarjet.

    Science.gov (United States)

    Hardy, Alexandre; Gerometta, Antoine; Granger, Benjamin; Massein, Audrey; Casabianca, Laurent; Pascal-Moussellard, Hugues; Loriaut, Philippe

    2018-01-01

    The Latarjet procedure has shown its efficiency for the treatment of anterior shoulder dislocation. The success of this technique depends on the correct positioning and fusion of the bone block. The length of the screws that fix the bone block can be a problem. They can increase the risk of non-union if too short or be the cause of nerve lesion or soft tissue discomfort if too long. Suprascapular nerve injuries have been reported during shoulder stabilisation surgery up to 6 % of the case. Bone block non-union depending on the series is found around 20 % of the cases. The purpose of this study was to evaluate the efficiency of this CT preoperative planning to predict optimal screws length. The clinical importance of this study lies in the observation that it is the first study to evaluate the efficiency of CT planning to predict screw length. Inclusion criteria were patients with chronic anterior instability of the shoulder with an ISIS superior to 4. Exclusion criteria were patients with multidirectional instability or any previous surgery on this shoulder. Thirty patients were included prospectively, 11 of them went threw a CT planning, before their arthroscopic Latarjet. Optimal length of both screws was calculated, adding the size of the coracoid at 5 and 15 mm from the tip to the glenoid. Thirty-two-mm screws were used for patients without planning. On a post-operative CT scan with 3D reconstruction, the distance between the screw tip and the posterior cortex was measured. A one-sample Wilcoxon test was used to compare the distance from the tip of the screw to an acceptable positioning of ±2 mm from the posterior cortex. In the group without planning, screw 1 tended to differ from the acceptable positioning: mean 3.44 mm ± 3.13, med 2.9 mm, q1; q3 [0.6; 4.75] p = 0.1118, and screw 2 differed significantly from the acceptable position: mean 4.83 mm ± 4.11, med 3.7 mm, q1; q3 [1.7; 5.45] p = 0.0045. In the group with planning, position of

  18. Study on pedicle screw fixation of cervical spine assisted CT-based navigation system compared with the individual cervical peddle screws placement technique

    International Nuclear Information System (INIS)

    He Xishun; Yang Huilin; Zhu Ruofu; Tan Xiangqi; Wang Genlin; Tang Tiansi

    2008-01-01

    Objective: To explore a safe and effective method for placing the cervical pedicle screws. Methods: There were ten adult cadaver specimens of cervica spine (C 1 -C 7 ) with intact structures including ligament and perivertebral muscles. The spiral computed tomography scan (Elscint CT Twin flash) at the section of 1 mm and three-dimensional reconstruction of all 10 cervical specimens were taken. By CT scan, the parameters of the cervical pedicles were measure,Then taking randomly 5 cervical specimens, according to the CT measurements, an appropriate screw was inserted into pedicle individually. In the other 5 human cadaver cervical vertebraes, Φ3.5 mm screws were inserted into the C 2 -C 7 pedicles by assisted by CT-based navigation system. Cortical integrity of every sample was examined by anatomic dissection, the spiral computed tomography scan and arrows,and coronal reconstruction. Results: Sixty screws was inserted into pedicle individually, and the achievement ratio was 90%, the perfectness ratio was 75%, 60 screws was placed into pedicle assisted by CT-based navigation system, and the achievement ratio was 96.6%, the perfectness ratio was 90%. By chi-square test for statistical analysis, there were no statistical significance between the accuracy rate of two methods(P>0.05). However there was statistical significance between the perfectness ratio between two methods(P<0.05). Conclusion: Compared with the individual cervical peddle screws placement technique, the perfectness ratio of pedicle screw fixation of cervical spine assisted by CT-based navigation system is higher, but there are no significant difference in accuracy. (authors)

  19. [Clinical efficacy of unilateral percutaneous transfacet screws combined with contralateral pedicle screw versus bilateral pedicle screws fixation in the treatment of the degenerative lumbar disease].

    Science.gov (United States)

    Hao, Rong-Xue; Zhou, Hui; Pan, Hao; Yue, Jun; Chen, Hui-Guo; Yang, He-Jie; Jia, Gao-Yong; Wang, Dong; Lin, Yan; Xu, Hua-Zi

    2017-09-25

    To investigate the surgical outcome of unilateral pedicle screw(UPS) after TLIF technique combined with contralateral percutaneous transfacet screw(PTS) fixation vs bilateral pedicle screws(BPS) fixation in treatment of degenerative lumbar disease. From January 2009 to June 2012, 46 patients with degenerative lumbar diseases, including 30 males and 16 females with an average age of 51.5 years old, who were divided into two groups according to different fixation methods. Twenty-two cases underwent UPS after TLIF technique combined with contralateral PTS fixation (group A), while the others underwent BPS fixation(group B). The relative data were analyzed, such as blood loss volume, operative time, fusion rate, ODI score, JOA score and so on. All the patients were followed up for 1 to 3 years with an average of 22 months. Except one case of each group was uncertainty fusion, the rest have obtained bony fusion, and the fusion rates in group A and B were 95.5% and 95.8%, respectively. No displacement and breakage of screw were found during follow-up. Operative time and blood loss volume in group A were better than of group B( P 0.05). Two approaches had similar clinical outcomes for degenerative lumbar disease with no severe instability. Compared with BPS fixation, the UPS after TLIF technique and contralateral PTS fixation has the advantages of less trauma, shorter operative time and less blood loss, and it is a safe and feasible surgical technique.

  20. Quantum noise locking

    International Nuclear Information System (INIS)

    McKenzie, Kirk; Mikhailov, Eugeniy E; Goda, Keisuke; Lam, Ping Koy; Grosse, Nicolai; Gray, Malcolm B; Mavalvala, Nergis; McClelland, David E

    2005-01-01

    Quantum optical states which have no coherent amplitude, such as squeezed vacuum states, cannot rely on standard readout techniques to generate error signals for control of the quadrature phase. Here we investigate the use of asymmetry in the quadrature variances to obtain a phase-sensitive readout and to lock the phase of a squeezed vacuum state, a technique which we call noise locking (NL). We carry out a theoretical derivation of the NL error signal and the associated stability of the squeezed and anti-squeezed lock points. Experimental data for the NL technique both in the presence and absence of coherent fields are shown, including a comparison with coherent locking techniques. Finally, we use NL to enable a stable readout of the squeezed vacuum state on a homodyne detector

  1. ''Old'' locked inflation

    International Nuclear Information System (INIS)

    Liu, Yang; Piao, Yun-Song; Si, Zong-Guo

    2009-01-01

    In this paper, we revisit the idea of locked inflation, which does not require a potential satisfying the normal slow-roll condition, but suffers from the problems associated with ''saddle inflation''. We propose a scenario based on locked inflation, however, with an alternative evolution mechanism of the ''waterfall field'' φ. Instead of rolling down along the potential, the φ field will tunnel to end the inflation stage like in old inflation, by which the saddle inflation could be avoided. Further, we study a cascade of old locked inflation, which can be motivated by the string landscape. Our model is based on the consideration of making locked inflation feasible so as to give a working model without slow roll; It also can be seen as an effort to embed the old inflation in string landscape

  2. On Helical Projection and Its Application in Screw Modeling

    Directory of Open Access Journals (Sweden)

    Riliang Liu

    2014-04-01

    Full Text Available As helical surfaces, in their many and varied forms, are finding more and more applications in engineering, new approaches to their efficient design and manufacture are desired. To that end, the helical projection method that uses curvilinear projection lines to map a space object to a plane is examined in this paper, focusing on its mathematical model and characteristics in terms of graphical representation of helical objects. A number of interesting projective properties are identified in regard to straight lines, curves, and planes, and then the method is further investigated with respect to screws. The result shows that the helical projection of a cylindrical screw turns out to be a Jordan curve, which is determined by the screw's axial profile and number of flights. Based on the projection theory, a practical approach to the modeling of screws and helical surfaces is proposed and illustrated with examples, and its possible application in screw manufacturing is discussed.

  3. Accuracy of S2 Alar-Iliac Screw Placement Under Robotic Guidance.

    Science.gov (United States)

    Laratta, Joseph L; Shillingford, Jamal N; Lombardi, Joseph M; Alrabaa, Rami G; Benkli, Barlas; Fischer, Charla; Lenke, Lawrence G; Lehman, Ronald A

    Case series. To determine the safety and feasibility of S2 alar-iliac (S2AI) screw placement under robotic guidance. Similar to standard iliac fixation, S2AI screws aid in achieving fixation across the sacropelvic junction and decreasing S1 screw strain. Fortunately, the S2AI technique minimizes prominent instrumentation and the need for offset connectors to the fusion construct. Herein, we present an analysis of the largest series of robotic-guided S2AI screws in the literature without any significant author conflicts of interest with the robotics industry. Twenty-three consecutive patients who underwent spinopelvic fixation with 46 S2AI screws under robotic guidance were analyzed from 2015 to 2016. Screws were placed by two senior spine surgeons, along with various fellow or resident surgical assistants, using a proprietary robotic guidance system (Renaissance; Mazor Robotics Ltd., Caesara, Israel). Screw position and accuracy was assessed on intraoperative CT O-arm scans and analyzed using three-dimensional interactive viewing and manipulation of the images. The average caudal angle in the sagittal plane was 31.0° ± 10.0°. The average horizontal angle in the axial plane using the posterior superior iliac spine as a reference was 42.8° ± 6.6°. The average S1 screw to S2AI screw angle was 11.3° ± 9.9°. Two violations of the iliac cortex were noted, with an average breach distance of 7.9 ± 4.8 mm. One breach was posterior (2.2%) and one was anterior (2.2%). The overall robotic S2AI screw accuracy rate was 95.7%. There were no intraoperative neurologic, vascular, or visceral complications related to the placement of the S2AI screws. Spinopelvic fixation achieved using a bone-mounted miniature robotic-guided S2AI screw insertion technique is safe and reliable. Despite two breaches, no complications related to the placement of the S2AI screws occurred in this series. Level IV, therapeutic. Copyright © 2017 Scoliosis Research Society. Published by Elsevier

  4. Development and Testing of X-Ray Imaging-Enhanced Poly-L-Lactide Bone Screws.

    Directory of Open Access Journals (Sweden)

    Wei-Jen Chang

    Full Text Available Nanosized iron oxide particles exhibit osteogenic and radiopaque properties. Thus, iron oxide (Fe3O4 nanoparticles were incorporated into a biodegradable polymer (poly-L-lactic acid, PLLA to fabricate a composite bone screw. This multifunctional, 3D printable bone screw was detectable on X-ray examination. In this study, mechanical tests including three-point bending and ultimate tensile strength were conducted to evaluate the optimal ratio of iron oxide nanoparticles in the PLLA composite. Both injection molding and 3D printing techniques were used to fabricate the PLLA bone screws with and without the iron oxide nanoparticles. The fabricated screws were implanted into the femoral condyles of New Zealand White rabbits. Bone blocks containing the PLLA screws were resected 2 and 4 weeks after surgery. Histologic examination of the surrounding bone and the radiopacity of the iron-oxide-containing PLLA screws were evaluated. Our results indicated that addition of iron oxide nanoparticles at 30% significantly decreased the ultimate tensile stress properties of the PLLA screws. The screws with 20% iron oxide exhibited strong radiopacity compared to the screws fabricated without the iron oxide nanoparticles. Four weeks after surgery, the average bone volume of the iron oxide PLLA composite screws was significantly greater than that of PLLA screws without iron oxide. These findings suggested that biodegradable and X-ray detectable PLLA bone screws can be produced by incorporation of 20% iron oxide nanoparticles. Furthermore, these screws had significantly greater osteogenic capability than the PLLA screws without iron oxide.

  5. Biomechanical properties of a novel biodegradable magnesium-based interference screw

    Directory of Open Access Journals (Sweden)

    Marco Ezechieli

    2016-06-01

    Full Text Available Magnesium-based interference screws may be an alternative in anterior/posterior cruciate ligament reconstruction. The well-known osteoconductive effects of biodegradable magnesium alloys may be useful. It was the purpose of this study to evaluate the biomechanical properties of a magnesium based interference screw and compare it to a standard implant. A MgYREZr-alloy interference screw and a standard implant (Milagro®; De Puy Mitek, Raynham, MA, USA were used for graft fixation. Specimens were placed into a tensile loading fixation of a servohydraulic testing machine. Biomechanical analysis included pretensioning of the constructs at 20 N for 1 min following cyclic pretensioning of 20 cycles between 20 and 60 N. Biomechanical elongation was evaluated with cyclic loading of 1000 cycles between 50 and 200 N at 0.5 Hz. Maximum load to failure was 511.3±66.5 N for the Milagro® screw and 529.0±63.3 N for magnesium-based screw (ns, P=0.57. Elongations after preload, during cyclical loading and during failure load were not different between the groups (ns, P>0.05. Stiffness was 121.1±13.8 N/mm for the magnesiumbased screw and 144.1±18.4 for the Milagro® screw (ns, P=0.32. MgYREZr alloy interference screws show comparable results in biomechanical testing to standard implants and may be an alternative for anterior cruciate reconstruction in the future.

  6. Frequency-Locked Detector Threshold Setting Criteria Based on Mean-Time-To-Lose-Lock (MTLL) for GPS Receivers.

    Science.gov (United States)

    Jin, Tian; Yuan, Heliang; Zhao, Na; Qin, Honglei; Sun, Kewen; Ji, Yuanfa

    2017-12-04

    Frequency-locked detector (FLD) has been widely utilized in tracking loops of Global Positioning System (GPS) receivers to indicate their locking status. The relation between FLD and lock status has been seldom discussed. The traditional PLL experience is not suitable for FLL. In this paper, the threshold setting criteria for frequency-locked detector in the GPS receiver has been proposed by analyzing statistical characteristic of FLD output. The approximate probability distribution of frequency-locked detector is theoretically derived by using a statistical approach, which reveals the relationship between probabilities of frequency-locked detector and the carrier-to-noise ratio ( C / N ₀) of the received GPS signal. The relationship among mean-time-to-lose-lock (MTLL), detection threshold and lock probability related to C / N ₀ can be further discovered by utilizing this probability. Therefore, a theoretical basis for threshold setting criteria in frequency locked loops for GPS receivers is provided based on mean-time-to-lose-lock analysis.

  7. Distraction osteogenesis using combined locking plate and Ilizarov fixator in the treatment of bone defect: A report of 2 cases

    Directory of Open Access Journals (Sweden)

    John Mukhopadhaya

    2017-01-01

    Full Text Available Distraction osteogenesis and bone transport has been used to reconstruct bone loss defect by allowing new bone to form in the gap. Plate-guided bone transport has been successfully described in literature to treat bone loss defect in the femur, tibia, and mandible. This study reports two cases of fracture of femur with segmental bone loss treated with locking plate fixation and bone transport with Ilizarov ring fixator. At the time of docking, when the transport segment is compressed with bone fragment, the bone fragment is fixed with additional locking or nonlocking screws through the plate. The bone defect size was 7 cm in case 1 and 8 cm in case 2 and the external fixation indexes were 12.7 days/cm and 14 days/cm. No shortening was present in either of our cases. The average radiographic consolidation index was 37 days/cm. Both cases achieved infection-free bone segment regeneration and satisfactorily functional outcome. This technique reduces the duration of external fixation during the consolidation phase, allows correction of length and alignment and provides earlier rehabilitation.

  8. Effects on Subtalar Joint Stress Distribution After Cannulated Screw Insertion at Different Positions and Directions.

    Science.gov (United States)

    Yuan, Cheng-song; Chen, Wan; Chen, Chen; Yang, Guang-hua; Hu, Chao; Tang, Kang-lai

    2015-01-01

    We investigated the effects on subtalar joint stress distribution after cannulated screw insertion at different positions and directions. After establishing a 3-dimensional geometric model of a normal subtalar joint, we analyzed the most ideal cannulated screw insertion position and approach for subtalar joint stress distribution and compared the differences in loading stress, antirotary strength, and anti-inversion/eversion strength among lateral-medial antiparallel screw insertion, traditional screw insertion, and ideal cannulated screw insertion. The screw insertion approach allowing the most uniform subtalar joint loading stress distribution was lateral screw insertion near the border of the talar neck plus medial screw insertion close to the ankle joint. For stress distribution uniformity, antirotary strength, and anti-inversion/eversion strength, lateral-medial antiparallel screw insertion was superior to traditional double-screw insertion. Compared with ideal cannulated screw insertion, slightly poorer stress distribution uniformity and better antirotary strength and anti-inversion/eversion strength were observed for lateral-medial antiparallel screw insertion. Traditional single-screw insertion was better than double-screw insertion for stress distribution uniformity but worse for anti-rotary strength and anti-inversion/eversion strength. Lateral-medial antiparallel screw insertion was slightly worse for stress distribution uniformity than was ideal cannulated screw insertion but superior to traditional screw insertion. It was better than both ideal cannulated screw insertion and traditional screw insertion for anti-rotary strength and anti-inversion/eversion strength. Lateral-medial antiparallel screw insertion is an approach with simple localization, convenient operation, and good safety. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Electromagnetic Lead Screw for Potential Wave Energy Application

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Wu, Weimin

    2014-01-01

    This paper presents a new type electromagnetic lead screw (EMLS) intended for wave energy application. Similar to the mechanical lead screw, this electromagnetic version can transfer slow linear motion to high-rotational motion, offering gearing effects. Compared with the existing pure magnetic...

  10. Bioresorbable screws reinforced with phosphate glass fibre: manufacturing and mechanical property characterisation.

    Science.gov (United States)

    Felfel, R M; Ahmed, I; Parsons, A J; Rudd, C D

    2013-01-01

    Use of bioresorbable screws could eliminate disadvantages associated with metals such as removal operations, corrosion, MRI interference and stress shielding. Mechanical properties of bioresorbable polymers alone are insufficient for load bearing applications application as screws. Thus, reinforcement is necessary to try and match or surpass the mechanical properties of cortical bone. Phosphate based glass fibres were used to reinforce polylactic acid (PLA) in order to produce unidirectionally aligned (UD) and unidirectionally plus randomly distributed (UD/RM) composite screws (P40 UD and P40 UD/RM). The maximum flexural and push-out properties for the composite screws (P40 UD and P40 UD/RM) increased by almost 100% in comparison with the PLA screws. While the pull-out strength and stiffness of the headless composite screws were ∼80% (strength) and ∼130% (stiffness) higher than for PLA, those with heads exhibited properties lower than those for PLA alone as a result of failure at the heads. An increase in the maximum shear load and stiffness for the composite screws (∼30% and ∼40%) in comparison to the PLA screws was also seen. Maximum torque for the PLA screws was ∼1000 mN m, while that for the composite screws were slightly lower. The SEM micrographs for P40 UD and P40 UD/RM screws revealed small gaps around the fibres, which were suggested to be due to buckling of the UD fibres during the manufacturing process. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. 49 CFR 236.766 - Locking, movable bridge.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, movable bridge. 236.766 Section 236.766... Locking, movable bridge. The rail locks, bridge locks, bolt locks, circuit controllers, and electric locks used in providing interlocking protection at a movable bridge. ...

  12. Biomechanical properties of orthogonal plate configuration versus parallel plate configuration using the same locking plate system for intra-articular distal humeral fractures under radial or ulnar column axial load.

    Science.gov (United States)

    Kudo, Toshiya; Hara, Akira; Iwase, Hideaki; Ichihara, Satoshi; Nagao, Masashi; Maruyama, Yuichiro; Kaneko, Kazuo

    2016-10-01

    Previous reports have questioned whether an orthogonal or parallel configuration is superior for distal humeral articular fractures. In previous clinical and biomechanical studies, implant failure of the posterolateral plate has been reported with orthogonal configurations; however, the reason for screw loosening in the posterolateral plate is unclear. The purpose of this study was to evaluate biomechanical properties and to clarify the causes of posterolateral plate loosening using a humeral fracture model under axial compression on the radial or ulnar column separately. And we changed only the plate set up: parallel or orthogonal. We used artificial bone to create an Association for the Study of Internal Fixation type 13-C2.3 intra-articular fracture model with a 1-cm supracondylar gap. We used an anatomically-preshaped distal humerus locking compression plate system (Synthes GmbH, Solothurn, Switzerland). Although this is originally an orthogonal plate system, we designed a mediolateral parallel configuration to use the contralateral medial plate instead of the posterolateral plate in the system. We calculated the stiffness of the radial and ulnar columns and anterior movement of the condylar fragment in the lateral view. The parallel configuration was superior to the orthogonal configuration regarding the stiffness of the radial column axial compression. There were significant differences between the two configurations regarding anterior movement of the capitellum during axial loading of the radial column. The posterolateral plate tended to bend anteriorly under axial compression compared with the medial or lateral plate. We believe that in the orthogonal configuration axial compression induced more anterior displacement of the capitellum than the trochlea, which eventually induced secondary fragment or screw dislocation on the posterolateral plate, or nonunion at the supracondylar level. In the parallel configuration, anterior movement of the capitellum or

  13. Process and apparatus for optimizing screwing position for closure stud

    International Nuclear Information System (INIS)

    Bourdonne, J.C.; Briand, A.

    1987-01-01

    The stud is fixed to a screwing and unscrewing device. The vertical position and alignment of the stud with the axis of the threated hole is checking. The stud is descended into the hole and rotated in the unscrewing direction. After detection of the point of engagement, the stud is rotated in the screwing direction. When a gamming is detected the descent is stopped and the screwing device is positioned in a new position. When the screwing couple returns below the disconnection couple, the stud is rotated with a reduced speed and then with a normal speed until the end [fr

  14. Unified Internet Messaging

    OpenAIRE

    Healy, Paul; Barber, Declan

    2015-01-01

    As telephony services, mobile services and internet services continue to converge, the prospect of providing Unified Messaging and even Unified Communications becomes increasingly achievable. This paper discusses the growing importance of IP-based networks to Unified Messaging developments and examines some of the key services and protocols that are likely to make Unified Messaging more widely available. In this initial paper, we limit ourselves initially to the unification of text-based mess...

  15. Grid deformation strategies for CFD analysis of screw compressors

    OpenAIRE

    Rane, S.; Kovacevic, A.; Stosic, N.; Kethidi, M.

    2013-01-01

    Customized grid generation of twin screw machines for CFD analysis is widely used by the refrigeration and air-conditioning industry today, but is currently not suitable for topologies such as those of single screw, variable pitch or tri screw rotors. This paper investigates a technique called key-frame re-meshing that supplies pre-generated unstructured grids to the CFD solver at different time steps. To evaluate its accuracy, the results of an isentropic compression-expansion process in a r...

  16. Tests for the dynamic behavior of insulation valve screws

    International Nuclear Information System (INIS)

    Tulke, K.D.; Stoppler, W.; Stern, G.

    1994-01-01

    Thermal tensile tests were performed at a temperature of 270 C, with two new original insulation valve conical screws M30-Tx92,5 mm (material: 21 CrMo V 5 7)and two prestrained ones during the event on 27.12.92. In order to assure the results obtained with regard to the dynamic load on the insulation valve during ''quick opening'', in addition tensile impact tests were performed at 270 C with six original insulation valve conical screws. Impact velocity reached 13,5 m/s at four screws and 6 m/s at two screws. Test conditions regarding collision damping and mass distribution were adapted, by means of parameter studies, to the situation of the insulation valve. During thermal tensile tests, strength and deformation values, such as stress at flow start, tensile strength, fracture prolongation and strain, necking at fracture as well as energy absorption up to maximum force and up to rupture, were determined. During tensile impact tests, deformation values, such as elongation, strain and necking, and energy absorption by the screw, were determined. (orig.) [de

  17. Research of mechanism of density lock

    International Nuclear Information System (INIS)

    Wang Shengfei; Yan Changqi; Gu Haifeng

    2010-01-01

    Mechanism of density lock was analyzed according to the work conditions of density lock. The results showed that: the stratification with no disturbance satisfied the work conditions of density lock; fluids between the stratification were not mixed at the condition of connected to each other; the density lock can be open automatically by controlled the pressure balance at the stratification. When disturbance existed, the stratification might be broken and mass would be transferred by convection. The stability of stratification can be enhanced by put the special structure in density lock to ensure the normal work of density lock. At last, the minimum of heat loss in density lock was also analyzed. (authors)

  18. Correction Capability in the 3 Anatomic Planes of Different Pedicle Screw Designs in Scoliosis Instrumentation.

    Science.gov (United States)

    Wang, Xiaoyu; Aubin, Carl-Eric; Coleman, John; Rawlinson, Jeremy

    2017-05-01

    Computer simulations to compare the correction capabilities of different pedicle screws in adolescent idiopathic scoliosis (AIS) instrumentations. To compare the correction and resulting bone-screw forces associated with different pedicle screws in scoliosis instrumentations. Pedicle screw fixation is widely used in surgical instrumentation for spinal deformity treatment. Screw design, correction philosophies, and surgical techniques are constantly evolving to achieve better control of the vertebrae and correction of the spinal deformity. Yet, there remains a lack of biomechanical studies that quantify the effects and advantages of different screw designs in terms of correction kinematics. The correction capabilities of fixed-angle, multiaxial, uniaxial, and saddle axial screws were kinematically analyzed, simulated, and compared. These simulations were based on the screw patterns and correction techniques proposed by 2 experienced surgeons for 2 AIS cases. Additional instrumentations were assessed to compare the correction and resulting bone-screw forces associated with each type of screw. The fixed-angle, uniaxial and saddle axial screws had similar kinematic behavior and performed better than multiaxial screws in the coronal and transverse planes (8% and 30% greater simulated corrections, respectively). Uniaxial and multiaxial screws were less effective than fixed-angle and saddle axial screws in transmitting compression/distraction to the anterior spine because of their sagittal plane mobility between the screw head and shank. Only the saddle axial screws allow vertebra angle in the sagittal plane to be independently adjusted. Pedicle screws of different designs performed differently for deformity corrections or for compensating screw placement variations in different anatomic planes. For a given AIS case, screw types should be determined based on the particular instrumentation objectives, the deformity's stiffness and characteristics so as to make the best of

  19. Performance of arm locking in LISA

    International Nuclear Information System (INIS)

    McKenzie, Kirk; Spero, Robert E.; Shaddock, Daniel A.

    2009-01-01

    For the Laser Interferometer Space Antenna (LISA) to reach its design sensitivity, the coupling of the free-running laser frequency noise to the signal readout must be reduced by more than 14 orders of magnitude. One technique employed to reduce the laser frequency noise will be arm locking, where the laser frequency is locked to the LISA arm length. In this paper we detail an implementation of arm locking. We investigate orbital effects (changing arm lengths and Doppler frequencies), the impact of errors in the Doppler knowledge that can cause pulling of the laser frequency, and the noise limit of arm locking. Laser frequency pulling is examined in two regimes: at lock acquisition and in steady state. The noise performance of arm locking is calculated with the inclusion of the dominant expected noise sources: ultrastable oscillator (clock) noise, spacecraft motion, and shot noise. We find that clock noise and spacecraft motion limit the performance of dual arm locking in the LISA science band. Studying these issues reveals that although dual arm locking [A. Sutton and D. A. Shaddock, Phys. Rev. D 78, 082001 (2008)] has advantages over single (or common) arm locking in terms of allowing high gain, it has disadvantages in both laser frequency pulling and noise performance. We address this by proposing a modification to the dual arm-locking sensor, a hybrid of common and dual arm-locking sensors. This modified dual arm-locking sensor has the laser frequency pulling characteristics and low-frequency noise coupling of common arm locking, but retains the control system advantages of dual arm locking. We present a detailed design of an arm-locking controller and perform an analysis of the expected performance when used with and without laser prestabilization. We observe that the sensor phase changes beneficially near unity-gain frequencies of the arm-locking controller, allowing a factor of 10 more gain than previously believed, without degrading stability. With a time

  20. Escaping carbon lock-in

    International Nuclear Information System (INIS)

    Unruh, G.C.

    2002-01-01

    This article explores the climate policy implications of the arguments made in ''Understanding carbon lock-in'' (Unruh, 2000), which posited that industrial countries have become locked-into fossil fuel-based energy systems through path dependent processes driven by increasing returns to scale. Carbon lock-in arises through technological, organizational, social and institutional co-evolution, ''culminating'' in what was termed as techno-institutional complex (TIC). In order to resolve the climate problem, an escape from the lock-in condition is required. However, due to the self-referential nature of TIC, escape conditions are unlikely to be generated internally and it is argued here that erogenous forces are probably required. (author)

  1. The improvement of screw compressor performance using a newly developed rotor profile

    International Nuclear Information System (INIS)

    Kishi, Takayuki; Nishio, Toshio; Matsui, Akira; Ino, Nobumi

    1994-01-01

    An oil-compression phenomenon occurs at two portions of a conventional oil injected screw compressor that degrades the isothermal efficiency of the screw compressor. Hence a new screw rotor profile and lubricant have been developed in order to avoid the above oil-compression phenomena. Mycom and Fermi National Accelerator Laboratory have measured the performance of a new Mycom compound type screw compressor 2016C using the new profile rotors and the new lubricant. In the experiments, a 33% enhancement rate in the isothermal efficiency of the new screw compressor installed in Fermilab was achieved

  2. Numerical study of internal flow in twin screw extruder and its mixing performance analysis

    International Nuclear Information System (INIS)

    Kim, Nak Soo; Kim, Hong Bum; Lee, Jae Wook

    2006-01-01

    We analyzed the non-Newtonian and non-isothermal flow in the melt conveying zone in co-rotating and counter-rotating screw extruder system with the commercial code, STAR-CD, and compared the mixing performance with respect to screw speed and rotating direction. The viscosity of fluid was described by power-law model. The dynamics of mixing was studied numerically by tracking the motion of particles in a twin screw extruder system. The extent of mixing was characterized in terms of the residence time distribution and average strain. The results showed that high screw speed decreases the residence time but increases the shear rate. Therefore higher screw speed increases the strain and has better mixing performance. Counter-rotating screw extruder system and co-rotating screw extruder has the similar shear rate with the same screw speed in spite of different rotating direction. However, the counter-rotating screw has good mixing performance, which is resulted from longer residence time than that of co-rotating screw extruder

  3. Homodyne locking of a squeezer.

    Science.gov (United States)

    Heurs, M; Petersen, I R; James, M R; Huntington, E H

    2009-08-15

    We report on the successful implementation of an approach to locking the frequencies of an optical parametric oscillator (OPO)-based squeezed-vacuum source and its driving laser. The technique allows the simultaneous measurement of the phase shifts induced by a cavity, which may be used for the purposes of frequency locking, as well as the simultaneous measurement of the sub-quantum-noise-limited (sub-QNL) phase quadrature output of the OPO. The homodyne locking technique is cheap, easy to implement, and has the distinct advantage that subsequent homodyne measurements are automatically phase locked. The homodyne locking technique is also unique in that it is a sub-QNL frequency discriminator.

  4. The biomechanical consequences of rod reduction on pedicle screws: should it be avoided?

    Science.gov (United States)

    Paik, Haines; Kang, Daniel G; Lehman, Ronald A; Gaume, Rachel E; Ambati, Divya V; Dmitriev, Anton E

    2013-11-01

    Rod contouring is frequently required to allow for appropriate alignment of pedicle screw-rod constructs. When residual mismatch is still present, a rod persuasion device is often used to achieve further rod reduction. Despite its popularity and widespread use, the biomechanical consequences of this technique have not been evaluated. To evaluate the biomechanical fixation strength of pedicle screws after attempted reduction of a rod-pedicle screw mismatch using a rod persuasion device. Fifteen 3-level, human cadaveric thoracic specimens were prepared and scanned for bone mineral density. Osteoporotic (n=6) and normal (n=9) specimens were instrumented with 5.0-mm-diameter pedicle screws; for each pair of comparison level tested, the bilateral screws were equal in length, and the screw length was determined by the thoracic level and size of the vertebra (35 to 45 mm). Titanium 5.5-mm rods were contoured and secured to the pedicle screws at the proximal and distal levels. For the middle segment, the rod on the right side was intentionally contoured to create a 5-mm residual gap between the inner bushing of the pedicle screw and the rod. A rod persuasion device was then used to engage the setscrew. The left side served as a control with perfect screw/rod alignment. After 30 minutes, constructs were disassembled and vertebrae individually potted. The implants were pulled in-line with the screw axis with peak pullout strength (POS) measured in Newton (N). For the proximal and distal segments, pedicle screws on the right side were taken out and reinserted through the same trajectory to simulate screw depth adjustment as an alternative to rod reduction. Pedicle screws reduced to the rod generated a 48% lower mean POS (495±379 N) relative to the controls (954±237 N) (p.05). In circumstances where a rod is not fully seated within the pedicle screw, the use of a rod persuasion device decreases the overall POS and work energy to failure of the screw or results in outright

  5. 49 CFR 236.765 - Locking, mechanical.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, mechanical. 236.765 Section 236.765 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, mechanical. An arrangement of locking bars, dogs, tappets, cross locking and other apparatus by...

  6. Pullout strength of misplaced pedicle screws in the thoracic and lumbar vertebrae - A cadaveric study

    Directory of Open Access Journals (Sweden)

    Shyam K Saraf

    2013-01-01

    Full Text Available Background: The objective of this cadaveric study was to analyze the effects of iatrogenic pedicle perforations from screw misplacement on the mean pullout strength of lower thoracic and lumbar pedicle screws. We also investigated the effect of bone mineral density (BMD, diameter of pedicle screws, and the region of spine on the pullout strength of pedicle screws. Materials and Methods: Sixty fresh human cadaveric vertebrae (D10-L2 were harvested. Dual-energy X-ray absorptiometry (DEXA scan of vertebrae was done for BMD. Titanium pedicle screws of different diameters (5.2 and 6.2 mm were inserted in the thoracic and lumbar segments after dividing the specimens into three groups: a standard pedicle screw (no cortical perforation; b screw with medial cortical perforation; and c screw with lateral cortical perforation. Finally, pullout load of pedicle screws was recorded using INSTRON Universal Testing Machine. Results: Compared with standard placement, medially misplaced screws had 9.4% greater mean pullout strength and laterally misplaced screws had 47.3% lesser mean pullout strength. The pullout strength of the 6.2 mm pedicle screws was 33% greater than that of the 5.2 mm pedicle screws. The pullout load of pedicle screws in lumbar vertebra was 13.9% greater than that in the thoracic vertebra ( P = 0.105, but it was not statistically significant. There was no significant difference between pullout loads of vertebra with different BMD ( P = 0.901. Conclusion: The mean pullout strength was less with lateral misplaced pedicle screws while medial misplaced pedicle screw had more pullout strength. The pullout load of 6.2 mm screws was greater than that of 5.2 mm pedicle screws. No significant correlation was found between bone mineral densities and the pullout strength of vertebra. Similarly, the pullout load of screw placed in thoracic and lumbar vertebrae was not significantly different.

  7. Intermaxillary Fixation Screw Morbidity in Treatment of Mandibular Fractures

    DEFF Research Database (Denmark)

    Florescu, Vlad-Andrei; Kofod, Thomas; Pinholt, Else Marie

    2016-01-01

    Purpose The aim of the present retrospective study was to investigate the morbidity of screws used for intermaxillary fixation (IMF) in the treatment of mandibular fractures. A review of the published data was also performed for a comparison of outcomes. Our hypothesis was that the use of screws...... for IMF of mandibular fractures would result in minimal morbidity. Materials and Methods Patients treated for mandibular fractures from 2007 to 2013, using screws for IMF, using the international diagnosis code for mandibular fracture, DS026, were anonymously selected (Department of Oral and Maxillofacial...... Surgery, Rigshospitalet, University Hospital of Copenhagen, Copenhagen, Denmark). The fracture type, radiographic findings, treatment modality, screw type and number, and root damage were recorded. For the outcome comparison, a review of the published data regarding iatrogenic dental root damage caused...

  8. The Analysis of Soil Resistance During Screw Displacement Pile Installation

    Science.gov (United States)

    Krasinski, Adam

    2015-02-01

    The application of screw displacement piles (SDP) is still increasing due to their high efficiency and many advantages. However, one technological problem is a serious disadvantage of those piles. It relates to the generation of very high soil resistance during screw auger penetration, especially when piles are installed in non-cohesive soils. In many situations this problem causes difficulties in creating piles of designed length and diameter. It is necessary to find a proper method for prediction of soil resistance during screw pile installation. The analysis of screw resistances based on model and field tests is presented in the paper. The investigations were carried out as part of research project, financed by the Polish Ministry of Science and Higher Education. As a result of tests and analyses the empirical method for prediction of rotation resistance (torque) during screw auger penetration in non-cohesive subsoil based on CPT is proposed.

  9. Comparison of accuracy of lag screw placement in cephalocondylic nails and sliding hip screw plate fixation for extracapsular fractures of the neck of femur

    OpenAIRE

    Shyam Kumar, A. J.; Parmar, V.; Bankart, J.; Williams, S. C.; Harper, W. M.

    2006-01-01

    This study compared the accuracy of lag screw placement between extracapsular femoral fractures fixed with sliding hip screw plate systems and those fixed with cephalocondylic nails. It involved 75 retrospective radiographs of fractures fixed with either a cephalocondylic nail (32) or a sliding hip screw plate system (43). Postoperative anteroposterior and lateral radiographs of the hip were scanned using a digital X-ray scanner and measured using computer software. Measurements were conducte...

  10. Process and device for the ultrasonic testing of slotted screws screwed into a head of a nuclear reactor fuel element for cracks

    International Nuclear Information System (INIS)

    Scharpenberg, R.

    1986-01-01

    To achieve correct echo signals, a test head is set separately on each area limited by a slot of the top of the slotted screw and the screw head is ultrasonically sounded in the direction of the suspected cracks. (orig./HP) [de

  11. Effect of diameter of the drill hole on torque of screw insertion and pushout strength for headless tapered compression screws in simulated fractures of the lateral condyle of the equine third metacarpal bone.

    Science.gov (United States)

    Carpenter, Ryan S; Galuppo, Larry D; Stover, Susan M

    2006-05-01

    To compare variables for screw insertion, pushout strength, and failure modes for a headless tapered compression screw inserted in standard and oversize holes in a simulated lateral condylar fracture model. 6 pairs of third metacarpal bones from horse cadavers. Simulated lateral condylar fractures were created, reduced, and stabilized with a headless tapered compression screw by use of a standard or oversize hole. Torque, work, and time for drilling, tapping, and screw insertion were measured during site preparation and screw implantation. Axial load and displacement were measured during screw pushout. Effects of drill hole size on variables for screw insertion and screw pushout were assessed by use of Wilcoxon tests. Drill time was 59% greater for oversize holes than for standard holes. Variables for tapping (mean maximum torque, total work, positive work, and time) were 42%, 70%, 73%, and 58% less, respectively, for oversize holes, compared with standard holes. Variables for screw pushout testing (mean yield load, failure load, failure displacement, and failure energy) were 40%, 40%, 47%, and 71% less, respectively, for oversize holes, compared with standard holes. Screws could not be completely inserted in 1 standard and 2 oversize holes. Enlarging the diameter of the drill hole facilitated tapping but decreased overall holding strength of screws. Therefore, holes with a standard diameter are recommended for implantation of variable pitch screws whenever possible. During implantation, care should be taken to ensure that screw threads follow tapped bone threads.

  12. The Analysis of Soil Resistance During Screw Displacement Pile Installation

    Directory of Open Access Journals (Sweden)

    Krasinski Adam

    2015-02-01

    Full Text Available The application of screw displacement piles (SDP is still increasing due to their high efficiency and many advantages. However, one technological problem is a serious disadvantage of those piles. It relates to the generation of very high soil resistance during screw auger penetration, especially when piles are installed in non-cohesive soils. In many situations this problem causes difficulties in creating piles of designed length and diameter. It is necessary to find a proper method for prediction of soil resistance during screw pile installation. The analysis of screw resistances based on model and field tests is presented in the paper. The investigations were carried out as part of research project, financed by the Polish Ministry of Science and Higher Education. As a result of tests and analyses the empirical method for prediction of rotation resistance (torque during screw auger penetration in non-cohesive subsoil based on CPT is proposed.

  13. Preload, Coefficient of Friction, and Thread Friction in an Implant-Abutment-Screw Complex.

    Science.gov (United States)

    Wentaschek, Stefan; Tomalla, Sven; Schmidtmann, Irene; Lehmann, Karl Martin

    To examine the screw preload, coefficient of friction (COF), and tightening torque needed to overcome the thread friction of an implant-abutment-screw complex. In a customized load frame, 25 new implant-abutment-screw complexes including uncoated titanium alloy screws were torqued and untorqued 10 times each, applying 25 Ncm. Mean preload values decreased significantly from 209.8 N to 129.5 N according to the number of repetitions. The overall COF increased correspondingly. There was no comparable trend for the thread friction component. These results suggest that the application of a used implant-abutment-screw complex may be unfavorable for obtaining optimal screw preload.

  14. Translaminar screw fixation in the lumbar spine: technique, indications, results

    OpenAIRE

    Grob, D.; Humke, T.

    1998-01-01

    Translaminar screw fixation of the lumbar spine represents a simple and effective technique for short segment fusion in the degenerative spine. Clinical experience with 173 patients who underwent translaminar screw fixation revealed a fusion rate of 94%. The indications for translaminar screw fixation as a primary fixation procedure are: segmental dysfunction, lumbar spinal stenosis with painful degenerative changes, segmental revision surgery after discectomies, and painful disc-related synd...

  15. Inspection and replacement of baffle assembly screws inside American reactor vessels

    International Nuclear Information System (INIS)

    Neal, K.; Chaumont, J.C.

    1999-01-01

    The baffle assembly inside the vessel of a 900 MWe reactor designed by Framatome, is made up of 44 plates fixed on 8 horizontal supports by a system of about 1000 screws. These plates undergo high neutron flux and the problem of screw cracking appeared at the end of the eighties in the first-generation reactors. The first operation on a large scale concerning the screws of a Westinghouse type reactor, was performed on the Tihange-1 power plant where Framatome controlled 960 screws and replaced 91. In 1997 as a consequence of the Belgian and French feedback experience, American plant operators launched a vast program of preventive actions: material analysis, inspection of baffle plate screws and replacement of defective screws. This program was held in cooperation with EPRI (electric power research institute) and under the control of NRC (nuclear regulatory commission). Framatome Technologies Inc (FTI) was in charge of the in-situ inspection and replacement of the screws. FTI designed special tools and equipment adapted to the 2-loop American reactors but the basis ideas were those applied on the Tihange reactor. The successful experience of FTI has allowed the firm to be commissioned for 6 2-loops American reactors. (A.C.)

  16. Fracture resistance of abutment screws made of titanium, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone

    Directory of Open Access Journals (Sweden)

    Eduardo Aloisio Fleck NEUMANN

    2014-08-01

    Full Text Available Fractured abutment screws may be replaced; however, sometimes, the screw cannot be removed and the entire implant must be surgically removed and replaced. The aim of this study was to compare the fracture resistance of abutment retention screws made of titanium, polyetheretherketone (PEEK and 30% carbon fiber-reinforced PEEK, using an external hexagonal implant/UCLA-type abutment interface assembly. UCLA-type abutments were fixed to implants using titanium screws (Group 1, polyetheretherketone (PEEK screws (Group 2, and 30% carbon fiber-reinforced PEEK screws (Group 3. The assemblies were placed on a stainless steel holding apparatus to allow for loading at 45o off-axis, in a universal testing machine. A 200 N load (static load was applied at the central point of the abutment extremity, at a crosshead speed of 5 mm/minute, until failure. Data was analyzed by ANOVA and Tukey’s range test. The titanium screws had higher fracture resistance, compared with PEEK and 30% carbon fiber-reinforced PEEK screws (p 0.05. Finally, visual analysis of the fractions revealed that 100% of them occurred at the neck of the abutment screw, suggesting that this is the weakest point of this unit. PEEK abutment screws have lower fracture resistance, in comparison with titanium abutment screws.

  17. Fracture resistance of abutment screws made of titanium, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone.

    Science.gov (United States)

    Neumann, Eduardo Aloisio Fleck; Villar, Cristina Cunha; França, Fabiana Mantovani Gomes

    2014-01-01

    Fractured abutment screws may be replaced; however, sometimes, the screw cannot be removed and the entire implant must be surgically removed and replaced. The aim of this study was to compare the fracture resistance of abutment retention screws made of titanium, polyetheretherketone (PEEK) and 30% carbon fiber-reinforced PEEK, using an external hexagonal implant/UCLA-type abutment interface assembly. UCLA-type abutments were fixed to implants using titanium screws (Group 1), polyetheretherketone (PEEK) screws (Group 2), and 30% carbon fiber-reinforced PEEK screws (Group 3). The assemblies were placed on a stainless steel holding apparatus to allow for loading at 45o off-axis, in a universal testing machine. A 200 N load (static load) was applied at the central point of the abutment extremity, at a crosshead speed of 5 mm/minute, until failure. Data was analyzed by ANOVA and Tukey's range test. The titanium screws had higher fracture resistance, compared with PEEK and 30% carbon fiber-reinforced PEEK screws (p 0.05). Finally, visual analysis of the fractions revealed that 100% of them occurred at the neck of the abutment screw, suggesting that this is the weakest point of this unit. PEEK abutment screws have lower fracture resistance, in comparison with titanium abutment screws.

  18. Strength evaluation of top nozzle holddown spring screw for nuclear fuel assembly

    International Nuclear Information System (INIS)

    Koh, S. K.; Won, S. Y.; Ryu, C. H.; Kim, Y. J.; Lee, K. S.; Jeon, K. L.

    2002-01-01

    Holddown springs are required to maintain the nuclear fuel assembly in contact with lower core plate and permit thermal and irradiation-induced length changes. Therefore, the holddown spring screw must be designed such that it is capable of sustaining the loads imposed by the initial tensile preload and operational loads. Prior to assessing the structural integrity of the spring screw in the corrosive and irradiating environment throughout the design lifetime of the fuel assembly, the strength evaluation of screw was made in this paper using the mechanics of materials and finite element methods. Calculations based on the mechanics of materials, showed that the preloaded screw with an operating holddown force had a quite large margin of safety in strength. However, the elastic-plastic finite element analysis showed that the local stresses at the critical regions of head-shank fillet and thread root significantly exceeded than the yield strength of the screw material, resulting in local plastic deformation. Preloading on the screw applied for tightening had beneficial effects on the screw strength by reducing the stress level at the critical regions, compared to the screw without preload. Calculated spring deflection using the finite element analysis was in close agreement with the experimentally measured deflection

  19. Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study

    OpenAIRE

    Krishna Chaitanya Kanneganti; Dileep Nag Vinnakota; Srinivas Rao Pottem; Mahesh Pulagam

    2018-01-01

    Purpose: The purpose of this study is to compare the effect of implant-abutment connections, abutment angulations, and screw lengths on screw loosening (SL) of preloaded abutment using three dimensional (3D) finite element analysis. Materials and Methods: 3D models of implants (conical connection with hex/trilobed connections), abutments (straight/angulated), abutment screws (short/long), and crown and bone were designed using software Parametric Technology Corporation Creo and assembled t...

  20. Protective air lock

    International Nuclear Information System (INIS)

    Evans, H.W.

    1976-01-01

    A device suitable for preventing escape and subsequent circulation of toxic gases is described. An enclosure is sealed by a surrounding air lock, and an automatic mechanism partially evacuates the enclosure and air lock. The enclosure ventilating mechanism can be disconnected so that a relatively undisturbed atmosphere is created in the enclosure

  1. Screw expander for light duty diesel engines

    Science.gov (United States)

    1983-01-01

    Preliminary selection and sizing of a positive displacement screw compressor-expander subsystem for a light-duty adiabatic diesel engine; development of a mathematical model to describe overall efficiencies for the screw compressor and expander; simulation of operation to establish overall efficiency for a range of design parameters and at given engine operating points; simulation to establish potential net power output at light-duty diesel operating points; analytical determination of mass moments of inertia for the rotors and inertia of the compressor-expander subsystem; and preparation of engineering layout drawings of the compressor and expander are discussed. As a result of this work, it was concluded that the screw compressor and expander designed for light-duty diesel engine applications are viable alternatives to turbo-compound systems, with acceptable efficiencies for both units, and only a moderate effect on the transient response.

  2. Control of influence of a thread on a bending of screws

    International Nuclear Information System (INIS)

    Proskuriakov, N E; Lopa, I V; Trapeznikov, E V

    2017-01-01

    The influence of the threads and the bending of screw on their moments of inertia of the cross section considered. This problem is actual since existing methods exclude from calculations the influence of supporting the thread, using as the basic geometrical parameter such as the internal diameter of the thread (diameter of cavities). Fundamental difference of a bend of the screw from a bend of a smooth rod consists that moment of inertia of the screw is a variable. It is shown that the change in cross-section moment of inertia along the length of the screw are essential and have periodic character. Analytical interrelation of the bending of the screw and the decreasing of moment of inertia of its cross section is established and equation describing this phenomenon is suggested. The greatest decrease of the moment of inertia occurs in the middle of the screw length, and the lowest - at its ends. Function and approximate coefficients for the main types of thread are proposed, which take into account this change. (paper)

  3. Bioabsorbable metal screws in traumatology: A promising innovation

    Directory of Open Access Journals (Sweden)

    Roland Biber

    2017-04-01

    Full Text Available MAGNEZIX® CS (Syntellix AG, Hanover, Germany is a bioabsorbable compression screw made of a magnesium alloy (MgYREZr. Currently there are only two clinical studies reporting on a limited number of elective patients who received this screw in a hallux valgus operation. We applied MAGNEZIX® CS for fixation of distal fibular fracture in a trauma patient who had sustained a bimalleolar fracture type AO 44-B2.3. Clinical course was uneventful, fracture healing occurred within three months. Follow-up X-rays showed a radiolucent area around the implant for some months, yet this radiolucent area had disappeared in the 17-months follow-up X-ray. Keywords: Magnesium, Bioabsorbable, Compression screw, Osteosynthesis, Ankle fracture

  4. Surgical treatment for old subaxial cervical dislocation with bilateral locked facets in a 3-year-old girl: A case report.

    Science.gov (United States)

    Li, Cheng; Li, Lei; Duan, Jingzhu; Zhang, Lijun; Liu, Zhenjiang

    2018-05-01

    This study aimed to describe the case of a 3-year-old girl with old bilateral facet dislocation on cervical vertebrae 6 and 7, who had spinal cord transection, received surgical treatment, and achieved a relative satisfactory therapeutic effect. A 3-year-old girl was urgently transferred to the hospital after a car accident. DIAGNOSES:: she was diagnosed with splenic rupture, intracranial hemorrhage, cervical dislocation, spinal transection, and Monteggia fracture of the left upper limb. The girl underwent emergency splenectomy and was transferred to the intensive care unit of the hospital 15 days later. One-stage anterior-posterior approach surgery (anterior discectomy, posterior laminectomy, and pedicle screw fixation) was performed when the patient stabilized after 45-day symptomatic treatment. The operation was uneventful. The reduction of lower cervical dislocation was satisfactory, with sufficient spinal cord decompression. The internal fixation position was good, and the spinal sequence was well restored. The girl was discharged 2 weeks later after the operation and followed up for 2 years. The major nerve function of both upper limbs was recovered, with no obvious retardation of the growth of immature spine. A satisfactory therapeutic effect was achieved for a pediatric old subaxial cervical dislocation with bilateral locked facets using anterior discectomy, posterior laminectomy, and pedicle screw fixation. The posterior pedicle screw fixation provided a good three-dimensional stability of the spine, with reduced risk and complications caused by anterior internal fixation. The growth of immature spine was not obviously affected during the 2-year follow-up.

  5. History of Retractor Technologies for Percutaneous Pedicle Screw Fixation Systems.

    Science.gov (United States)

    Mobbs, Ralph J; Phan, Kevin

    2016-02-01

    Minimally invasive techniques aimed at minimizing surgery-associated risk and morbidity of spinal surgery have increased in popularity in recent years. Their potential advantages include reduced length of hospital stay, blood loss, and requirement for post-operative analgesia and earlier return to work. One such minimally invasive technique is the use of percutaneous pedicle screw fixation, which is paramount for promoting rigid and stable constructs and fusion in the context of trauma, tumors, deformity and degenerative disease. Percutaneous pedicle screw insertion can be an intimidating prospect for surgeons who have only been trained in open techniques. One of the ongoing challenges of this percutaneous system is to provide the surgeon with adequate access to the pedicle entry anatomy and adequate tactile or visual feedback concerning the position and anatomy of the rod and set-screw construct. This review article discusses the history and evolution of percutaneous pedicle screw retractor technologies and outlines the advances over the last decade in the rapidly expanding field of minimal access surgery for posterior pedicle screw based spinal stabilization. As indications for percutaneous pedicle screw techniques expand, the nuances of the minimally invasive surgery techniques and associated technologies will also multiply. It is important that experienced surgeons have access to tools that can improve access with a greater degree of ease, simplicity and safety. We here discuss the technical challenges of percutaneous pedicle screw retractor technologies and a variety of systems with a focus on the pros and cons of various retractor systems. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  6. The Improvement of Bone-Tendon Fixation by Porous Titanium Interference Screw: A Rabbit Animal Model.

    Science.gov (United States)

    Tsai, Pei-I; Chen, Chih-Yu; Huang, Shu-Wei; Yang, Kuo-Yi; Lin, Tzu-Hung; Chen, San-Yuan; Sun, Jui-Sheng

    2018-05-04

    The interference screw is a widely used fixation device in the anterior cruciate ligament (ACL) reconstruction surgeries. Despite the generally satisfactory results, problems of using interference screws were reported. By using additive manufacturing (AM) technology, we developed an innovative titanium alloy (Ti 6 Al 4 V) interference screw with rough surface and inter-connected porous structure designs to improve the bone-tendon fixation. An innovative Ti 6 Al 4 V interference screws were manufactured by AM technology. In vitro mechanical tests were performed to validate its mechanical properties. Twenty-seven New Zealand white rabbits were randomly divided into control and AM screw groups for biomechanical analyses and histological analysis at 4, 8 and 12 weeks postoperatively; while micro-CT analysis was performed at 12 weeks postoperatively. The biomechanical tests showed that the ultimate failure load in the AM interference screw group was significantly higher than that in the control group at all tested periods. These results were also compatible with the findings of micro-CT and histological analyses. In micro-CT analysis, the bone-screw gap was larger in the control group; while for the additive manufactured screw, the screw and bone growth was in close contact. In histological study, the bone-screw gaps were wider in the control group and were almost invisible in the AM screw group. The innovative AM interference screws with surface roughness and inter-connected porous architectures demonstrated better bone-tendon-implant integration, and resulted in stronger biomechanical characteristics when compared to traditional screws. These advantages can be transferred to future interference screw designs to improve their clinical performance. The AM interference screw could improve graft fixation and eventually result in better biomechanical performance of the bone-tendon-screw construct. The innovative AM interference screws can be transferred to future

  7. Pressure locking test results

    Energy Technology Data Exchange (ETDEWEB)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D. [Idaho National Engineering Lab., Idaho Falls, ID (United States)] [and others

    1996-12-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.{close_quotes} Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; the authors will publish the results of their thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions.

  8. Pressure locking test results

    International Nuclear Information System (INIS)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D.

    1996-01-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, open-quotes Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.close quotes Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; we will publish the results of our thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions

  9. Failure analysis of top nozzle holddown spring screw for nuclear fuel assembly

    International Nuclear Information System (INIS)

    Koh, S. K.; Ryu, C. H.; Na, E. G.; Baek, T. H.; Jeon, K. L.

    2003-01-01

    A failure analysis of holddown spring screw was performed using fracture mechanics approach. The spring screw was designed such that it was capable of sustaining the loads imposed by the initial tensile preload and operational loads. In order to investigate the cause of failure, a stress analysis of the top nozzle spring assembly was done using finite element analysis and a life prediction of the screw was made using a fracture mechanics approach. The elastic-plastic finite element analysis showed that the local stresses at the critical regions of head-shank fillet and thread root significantly exceeded than the yield strength of the screw material, resulting in local plastic deformation. Primary water stress corrosion cracking life of the Inconel 600 screw was predicted by using integration of the Scott model and resulted in 1.42 years, which was fairly close to the actual service life of the holddown spring screw

  10. The Study of Vibration Processes in Oil Flooded Screw Compressors

    Directory of Open Access Journals (Sweden)

    I. V. Filippov

    2014-01-01

    Full Text Available Vibration processes that accompany most of machines and mechanisms are of interest to the researcher, as a source of information about the technical condition and the nature of the business processes flow. Vibration-based diagnostics of oil flooded screw compressors allows us to estimate the deviation of their operation from the main mode in accordance with changing the settings of vibration processes.The oil flooded screw compressor transition from the main mode of operation to the abnormal one is accompanied by complex gas-dynamic phenomena i.e. the initial gaps and their decays. This leads to changes in the nature of vibration processes, prompting suggestions that there is a relationship to a change of vibration parameters and mode of compressor operation.Studies were conducted by combined method using an analytical calculation of the decay parameters of the initial discontinuity and an experimental one based on the measurement of acceleration on the body of the real oil flooded screw compressor. A virtually adequate reaction of the decay parameters of the initial gap and the peak values of vibration acceleration to the change of operation mode of oil flooded screw compressor has been received. The peak value of the vibration acceleration was selected by the method of Gating being time-coinciding with the beginning discharge phase of the oil flooded screw compressor, and therefore, with the decay time of the initial discontinuity.This indicates a large degree of hypothesis likelihood on an existing initial break in oil flooded screw compressor when operating in abnormal conditions. This work contains the study results of vibration processes and their relationship to the operating mode of the oil flooded screw compressor, which distinguish it from the other works studied vibration processes in reciprocating compressors. The vibration parameters control of operating oil flooded screw compressor allows us to create an automatic capacity control

  11. Analysis of Material Flow in Screw Extrusion of Aluminum

    International Nuclear Information System (INIS)

    Haugen, Bjoern; Oernskar, Magnus; Welo, Torgeir; Wideroee, Fredrik

    2010-01-01

    Screw extrusion of aluminum is a new process for production of aluminum profiles. The commercial potential could be large. Little experimental and numerical work has been done with respect to this process.The material flow of hot aluminum in a screw extruder has been analyzed using finite element formulations for the non-Newtonian Navier-Stokes equations. Aluminum material properties are modeled using the Zener-Holloman material model. Effects of stick-slip conditions are investigated with respect to pressure build up and mixing quality of the extrusion process.The numerical results are compared with physical experiments using an experimental screw extruder.

  12. PWR integral tie plate and locking mechanism

    International Nuclear Information System (INIS)

    Flora, B.S.; Osborne, J.L.

    1980-01-01

    A locking mechanism for securing an upper tie plate to the tie rods of a nuclear fuel bundle is described. The mechanism includes an upper tie plate assembly and locking sleeves fixed to the ends of the tie rods. The tie plate is part of the upper tie plate assembly and is secured to the fuel bundle by securing the entire upper tie plate assembly to the locking sleeves fixed to the tie rods. The assembly includes, in addition to the tie plate, locking nuts for engaging the locking sleeves, retaining sleeves to operably connect the locking nuts to the assembly, a spring biased reaction plate to restrain the locking nuts in the locked position and a means to facilitate the removal of the entire assembly as a unit from the fuel bundle

  13. Decrease in Hydrogen Embrittlement Susceptibility of 10B21 Screws by Bake Aging

    Directory of Open Access Journals (Sweden)

    Kuan-Jen Chen

    2016-08-01

    Full Text Available The effects of baking on the mechanical properties and fracture characteristics of low-carbon boron (10B21 steel screws were investigated. Fracture torque tests and hydrogen content analysis were performed on baked screws to evaluate hydrogen embrittlement (HE susceptibility. The diffusible hydrogen content within 10B21 steel dominated the fracture behavior of the screws. The fracture torque of 10B21 screws baked for a long duration was affected by released hydrogen. Secondary ion mass spectroscopy (SIMS result showed that hydrogen content decreased with increasing baking duration, and thus the HE susceptibility of 10B21 screws improved. Diffusible hydrogen promoted crack propagation in high-stress region. The HE of 10B21 screws can be prevented by long-duration baking.

  14. Safety lock for radiography exposure device

    International Nuclear Information System (INIS)

    Gaines, T.M.

    1982-01-01

    A safety lock for securing a radiation source in a radiography exposure device is disclosed. The safety lock prevents the inadvertent extension of the radiation source from the exposure device. The exposure devices are used extensively in industry for nondestructive testing of metal materials for defect. Unnecessary exposure of the radiographer or operator occurs not infrequently due to operator's error in believing that the radiation source is secured in the exposure device when, in fact, it is not. The present invention solves this problem of unnecessary exposure by releasingly trapping the radiation source in the shield of the radiography exposure device each time the source is retracted therein so that it is not inadvertently extended therefrom without the operator resetting the safety lock, thereby releasing the radiation source. Further, the safety lock includes an indicator which indicates when the source is trapped in the exposure device and also when it is untrapped. The safety lock is so designed that it does not prevent the return of the source to the trapped, shielded position in the exposure device. Further the safety lock includes a key means for locking the radiation source in the trapped position. The key means cannot be actuated until said radiation source is in said trapped position to further insure the safety lock cannot be inadvertently locked with the source untrapped and thus still extendable from the exposure device

  15. The movement of screw dislocations in tungsten

    International Nuclear Information System (INIS)

    Tian Xiaogeng; Woo Chungho

    2004-01-01

    Using Acland potential for tungsten, the movement of 1/2a screw dislocation under shear stress was investigated by molecular dynamics simulation. Equilibrated core structure was obtained by relaxation of screw dislocation with proper boundary conditions. We found that the equilibrium dislocation core has three-fold symmetry and spread out in three direction on {1 1 0} planes. The screw dislocation core could not keep the original shape when the shear stress applied. The dislocation could not move until the shear stress became large enough. The dislocation moved in zigzag when the shear stress neared the Peierls stress. When the shear stress became larger, the dislocation moved in zigzag at the beginning and than moved almost in straight line in [2-bar11] direction. The large shear stress applied, the long distance moved before the dislocation stilled in z-direction and the large velocity in y-direction

  16. Screw Remaining Life Prediction Based on Quantum Genetic Algorithm and Support Vector Machine

    Directory of Open Access Journals (Sweden)

    Xiaochen Zhang

    2017-01-01

    Full Text Available To predict the remaining life of ball screw, a screw remaining life prediction method based on quantum genetic algorithm (QGA and support vector machine (SVM is proposed. A screw accelerated test bench is introduced. Accelerometers are installed to monitor the performance degradation of ball screw. Combined with wavelet packet decomposition and isometric mapping (Isomap, the sensitive feature vectors are obtained and stored in database. Meanwhile, the sensitive feature vectors are randomly chosen from the database and constitute training samples and testing samples. Then the optimal kernel function parameter and penalty factor of SVM are searched with the method of QGA. Finally, the training samples are used to train optimized SVM while testing samples are adopted to test the prediction accuracy of the trained SVM so the screw remaining life prediction model can be got. The experiment results show that the screw remaining life prediction model could effectively predict screw remaining life.

  17. Ball Nut Preload Diagnosis of the Hollow Ball Screw through Support Vector Machine

    Directory of Open Access Journals (Sweden)

    Yi-Cheng Huang

    2018-01-01

    Full Text Available This paper studies the diagnostic results of hollow ball screws with different ball nut preload through the support vector machine (SVM process. The method is testified by considering the use of ball screw pretension and different ball nut preload. SVM was used to discriminate the hollow ball screw preload status through the vibration signals and servo motor current signals. Maximum dynamic preloads of 2%, 4%, and 6% ball screws were predesigned, manufactured, and conducted experimentally. Signal patterns with different preload features are separatedby SVM. The irregularity development of the ball screw driving motion current and rolling balls vibration of the ball screw can be discriminated via SVM based on complexity perception. The experimental results successfully show that the prognostic status of ball nut preload can be envisaged by the proposed methodology. The smart reasoning for the health of the ball screw is available based on classification of SVM. This diagnostic method satisfies the purposes of prognostic effectiveness on knowing the ball nut preload status

  18. Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation

    Directory of Open Access Journals (Sweden)

    Katonis Pavlos G

    2009-05-01

    Full Text Available Abstract Background Lag screw cut-out failure following fixation of unstable intertrochanteric fractures in osteoporotic bone remains an unsolved challenge. This study tested if resistance to cut-out failure can be improved by using a dual lag screw implant in place of a single lag screw implant. Migration behavior and cut-out resistance of a single and a dual lag screw implant were comparatively evaluated in surrogate specimens using an established laboratory model of hip screw cut-out failure. Methods Five dual lag screw implants (Endovis, Citieffe and five single lag screw implants (DHS, Synthes were tested in the Hip Implant Performance Simulator (HIPS of the Legacy Biomechanics Laboratory. This model simulated osteoporotic bone, an unstable fracture, and biaxial rocking motion representative of hip loading during normal gait. All constructs were loaded up to 20,000 cycles of 1.45 kN peak magnitude under biaxial rocking motion. The migration kinematics was continuously monitored with 6-degrees of freedom motion tracking system and the number of cycles to implant cut-out was recorded. Results The dual lag screw implant exhibited significantly less migration and sustained more loading cycles in comparison to the DHS single lag screw. All DHS constructs failed before 20,000 cycles, on average at 6,638 ± 2,837 cycles either by cut-out or permanent screw bending. At failure, DHS constructs exhibited 10.8 ± 2.3° varus collapse and 15.5 ± 9.5° rotation around the lag screw axis. Four out of five dual screws constructs sustained 20,000 loading cycles. One dual screw specimens sustained cut-out by medial migration of the distal screw after 10,054 cycles. At test end, varus collapse and neck rotation in dual screws implants advanced to 3.7 ± 1.7° and 1.6 ± 1.0°, respectively. Conclusion The single and double lag screw implants demonstrated a significantly different migration resistance in surrogate specimens under gait loading simulation with

  19. Kinematic analysis of parallel manipulators by algebraic screw theory

    CERN Document Server

    Gallardo-Alvarado, Jaime

    2016-01-01

    This book reviews the fundamentals of screw theory concerned with velocity analysis of rigid-bodies, confirmed with detailed and explicit proofs. The author additionally investigates acceleration, jerk, and hyper-jerk analyses of rigid-bodies following the trend of the velocity analysis. With the material provided in this book, readers can extend the theory of screws into the kinematics of optional order of rigid-bodies. Illustrative examples and exercises to reinforce learning are provided. Of particular note, the kinematics of emblematic parallel manipulators, such as the Delta robot as well as the original Gough and Stewart platforms are revisited applying, in addition to the theory of screws, new methods devoted to simplify the corresponding forward-displacement analysis, a challenging task for most parallel manipulators. Stands as the only book devoted to the acceleration, jerk and hyper-jerk (snap) analyses of rigid-body by means of screw theory; Provides new strategies to simplify the forward kinematic...

  20. A rationale method for evaluating unscrewing torque values of prosthetic screws in dental implants

    Directory of Open Access Journals (Sweden)

    Felipe Miguel Saliba

    2011-02-01

    Full Text Available OBJECTIVES: Previous studies that evaluated the torque needed for removing dental implant screws have not considered the manner of transfer of the occlusal loads in clinical settings. Instead, the torque used for removal was applied directly to the screw, and most of them omitted the possibility that the hexagon could limit the action of the occlusal load in the loosening of the screws. The present study proposes a method for evaluating the screw removal torque in an anti-rotational device independent way, creating an unscrewing load transfer to the entire assembly, not only to the screw. MATERIAL AND METHODS: Twenty hexagonal abutments without the hexagon in their bases were fixed with a screw to 20 dental implants. They were divided into two groups: Group 1 used titanium screws and Group 2 used titanium screws covered with a solid lubricant. A torque of 32 Ncm was applied to the screw and then a custom-made wrench was used for rotating the abutment counterclockwise, to loosen the screw. A digital torque meter recorded the torque required to loosen the abutment. RESULTS: There was a significant difference between the means of Group 1 (38.62±6.43 Ncm and Group 2 (48.47±5.04 Ncm, with p=0.001. CONCLUSION: This methodology was effective in comparing unscrewing torque values of the implant-abutment junction even with a limited sample size. It confirmed a previously shown significant difference between two types of screws.

  1. Biomechanical evaluation of a new MatrixMandible plating system on cadaver mandibles.

    Science.gov (United States)

    Gateno, Jaime; Cookston, Christopher; Hsu, Sam Sheng-Pin; Stal, Drew N; Durrani, Salim K; Gold, Jonathan; Ismaily, Sabir; Alexander, Jerry W; Noble, Philip C; Xia, James J

    2013-11-01

    Current mandibular plating systems contain a wide range of plates and screws needed for the treatment of mandibular reconstruction and mandibular fractures. The authors' hypothesis was that a single diameter screw could be used in all applications in a plating system. Therefore, the purpose of this study was to test if the 2.0-mm locking screws could replace the 2.4-mm screws to stabilize a 2.5-mm-thick reconstruction plate in the treatment of mandibular discontinuity. Thirty-six fresh human cadaveric mandibles were used: 18 were plated using 2.0-mm locking screws (experimental) and the other 18 were plated using 2.4-mm locking screws (control). Each group was further divided into 3 subgroups based on the site of loading application: the ipsilateral (right) second premolar region, the central incisal region, and the contralateral (left) first molar region. The same ipsilateral (right) mandibular angular discontinuity was created by the same surgeon. The mandible was mounted on a material testing machine. The micromotions between the 2 segments, permanent and elastic displacements, were recorded after incremental ramping loads. The magnitude of screw back-out and the separation between plate and bone were recorded using a laser scanner (resolution, 0.12 mm) before and after the loading applications. The data were processed. Descriptive analyses and a general linear model for repeated measures analysis of variance were performed. There was no statistically significant difference in permanent displacement (mean, 1.16 and 0.82 mm, respectively) between the 2.0-mm and 2.4-mm screw groups. There also was no statistically significant difference in elastic displacement between the 2 groups (mean, 1.48 and 1.21 mm, respectively). Finally, there were no statistically significant differences in screw back-out or separation between plate and bone between the 2 groups. All means for screw back-out and separation between screw and bone for each group were judged within the

  2. Current trends in pedicle screw stimulation techniques: lumbosacral, thoracic, and cervical levels.

    Science.gov (United States)

    Isley, Michael R; Zhang, Xiao-Feng; Balzer, Jeffrey R; Leppanen, Ronald E

    2012-06-01

    Unequivocally, pedicle screw instrumentation has evolved as a primary construct for the treatment of both common and complex spinal disorders. However an inevitable and potentially major complication associated with this type of surgery is misplacement of a pedicle screw(s) which may result in neural and vascular complications, as well as impair the biomechanical stability of the spinal instrumentation resulting in loss of fixation. In light of these potential surgical complications, critical reviews of outcome data for treatment of chronic, low-back pain using pedicle screw instrumentation concluded that "pedicle screw fixation improves radiographically demonstrated fusion rates;" however the expense and complication rates for such constructs are considerable in light of the clinical benefit (Resnick et al. 2005a). Currently, neuromonitoring using free-run and evoked (triggered) electromyography (EMG) is widely used and advocated for safer and more accurate placement of pedicle screws during open instrumentation procedures, and more recently, guiding percutaneous placement (minimally invasive) where the pedicle cannot be easily inspected visually. The latter technique, evoked or triggered EMG when applied to pedicle screw instrumentation surgeries, has been referred to as the pedicle screw stimulation technique. As concluded in the Position Statement by the American Society of Neurophysiological Monitoring (ASNM), multimodality neuromonitoring using free-run EMG and the pedicle screw stimulation technique was considered a practice option and not yet a standard of care (Leppanen 2005). Subsequently, the American Association of Neurological Surgeons/Congress of Neurological Surgeons (AANS/CNS) Joint Section on Disorders of the Spine and Peripheral Nerves published their "Guidelines for the Performance of Fusion Procedures for Degenerative Disease of the Lumbar Spine" (Heary 2005, Resnick et al. 2005a, Resnick et al. 2005b). It was concluded that the "primary

  3. Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study

    Directory of Open Access Journals (Sweden)

    Krishna Chaitanya Kanneganti

    2018-01-01

    Conclusions: The present study suggests selecting appropriate implant-abutment connection based on the abutment angulation, as well as preferring long screws with more number of threads for effective preload retention by the screws.

  4. Accelerated Tooth Movement with Orthodontic Mini-Screws

    Directory of Open Access Journals (Sweden)

    S. Aksakalli

    2017-01-01

    Full Text Available This case report outlines the possibility of accelerated tooth movement with the combination of microosteoperforation and mini-screws. A 14-year-old male patient presented Class II malocclusion with maxillary incisor protrusion. Upper first premolars were extracted, and after leveling, accelerated canine distalization started. For pre- and postdistalization times, amount of distalization, periodontal health, and root resorption were assessed. Within the limitations of this case report, micro-osteoperforations with mini-screw have a potential for shortening the treatment time.

  5. Experimental study of the density distribution of the particles of the material in screw installation

    Directory of Open Access Journals (Sweden)

    Demidov S. F.

    2017-02-01

    Full Text Available the experimental studies of density distribution of the particles of a mixture of wheat, oats, rye to feed pigs by infrared heating at the time of stay and temperature at the exit of the installation. The purpose of the work is to study the quality of treatment of the product with the settings with the screw and the screw with installed round jumper on the pen of the screw. Screw installations with infrared emitters of selected wavelength give the opportunity for intense and continuous heat treatment process. The authors used the optimal parameters of the process with the screw and the screw with installed round jumper on the pen of the screw. The parameters of screw installation during the study were the following: the number of revolutions of the screw was 10 rpm, density of heat flux was 12 kW/m2, output capacity – 250 kg/h.

  6. Oral mucosa tissue response to titanium cover screws.

    Science.gov (United States)

    Olmedo, Daniel G; Paparella, María L; Spielberg, Martín; Brandizzi, Daniel; Guglielmotti, María B; Cabrini, Rómulo L

    2012-08-01

    Titanium is the most widely used metal in dental implantology. The release of particles from metal structures into the biologic milieu may be the result of electrochemical processes (corrosion) and/or mechanical disruption during insertion, abutment connection, or removal of failing implants. The aim of the present study is to evaluate tissue response of human oral mucosa adjacent to titanium cover screws. One hundred fifty-three biopsies of the supra-implant oral mucosa adjacent to the cover screw of submerged dental implants were analyzed. Histologic studies were performed to analyze epithelial and connective tissue as well as the presence of metal particles, which were identified using microchemical analysis. Langerhans cells, macrophages, and T lymphocytes were studied using immunohistochemical techniques. The surface of the cover screws was evaluated by scanning electron microscopy (SEM). Forty-one percent of mucosa biopsies exhibited metal particles in different layers of the section thickness. Particle number and size varied greatly among specimens. Immunohistochemical study confirmed the presence of macrophages and T lymphocytes associated with the metal particles. Microchemical analysis revealed the presence of titanium in the particles. On SEM analysis, the surface of the screws exhibited depressions and irregularities. The biologic effects seen in the mucosa in contact with the cover screws might be associated with the presence of titanium or other elements, such as aluminum or vanadium. The potential long-term biologic effects of particles on soft tissues adjacent to metallic devices should be further investigated because these effects might affect the clinical outcome of the implant.

  7. Effectiveness of screw surface coating on the stability of zirconia abutments after cyclic loading.

    Science.gov (United States)

    Basílio, Mariana de Almeida; Butignon, Luis Eduardo; Arioli Filho, João Neudenir

    2012-01-01

    Different surface treatments have been developed in attempts to prevent the loosening of abutment screws. The aim of the current study was to compare the effectiveness of titanium alloy screws with tungsten-doped diamond-like carbon (W-DLC) coating and uncoated screws in providing stability to zirconia (ZrO2) ceramic abutments after cyclic loading. Twenty prefabricated ZrO2 ceramic abutments on their respective external-hex implants were divided into two groups of equal size according to the type of screw used: uncoated titanium alloy screw (Ti) or titanium alloy screw with W-DLC coating (W-DLC/Ti). The removal torque value (preload) of the abutment screw was measured before and after loading. Cyclic loading between 11 and 211 N was applied at an angle of 30 degrees to the long axis of the implants at a frequency of 15 Hz. A target of 0.5 X 106 cycles was defined. Group means were calculated and compared using analysis of variance and the F test (α = .05). Before cyclic loading, the preload for Ti screws was significantly higher than that for W-DLC/Ti screws (P = .021). After cyclic loading, there was no significant difference between them (P = .499). Under the studied conditions, it can be concluded that, after cyclic loading, both abutment screws presented a significant reduction in the mean retained preload and similar effectiveness in maintaining preload.

  8. Mechanical comparison between lengthened and short sacroiliac screws in sacral fracture fixation: a finite element analysis.

    Science.gov (United States)

    Zhao, Y; Zhang, S; Sun, T; Wang, D; Lian, W; Tan, J; Zou, D; Zhao, Y

    2013-09-01

    To compare the stability of lengthened sacroiliac screw and standard sacroiliac screw for the treatment of unilateral vertical sacral fractures; to provide reference for clinical applications. A finite element model of Tile type C pelvic ring injury (unilateral Denis type II fracture of the sacrum) was produced. The unilateral sacral fractures were fixed with lengthened sacroiliac screw and sacroiliac screw in six different types of models respectively. The translation and angle displacement of the superior surface of the sacrum (in standing position on both feet) were measured and compared. The stability of one lengthened sacroiliac screw fixation in S1 or S2 segment is superior to that of one sacroiliac screw fixation in the same sacral segment. The stability of one lengthened sacroiliac screw fixation in S1 and S2 segments respectively is superior to that of one sacroiliac screw fixation in S1 and S2 segments respectively. The stability of one lengthened sacroiliac screw fixation in S1 and S2 segments respectively is superior to that of one lengthened sacroiliac screw fixation in S1 or S2 segment. The stability of one sacroiliac screw fixation in S1 and S2 segments respectively is markedly superior to that of one sacroiliac screw fixation in S1 or S2 segment. The vertical and rotational stability of lengthened sacroiliac screw fixation and sacroiliac screw fixation in S2 is superior to that of S1. In a finite element model of type C pelvic ring disruption, S1 and S2 lengthened sacroiliac screws should be utilized for the fixation as regularly as possible and the most stable fixation is the combination of the lengthened sacroiliac screws of S1 and S2 segments. Even if lengthened sacroiliac screws cannot be systematically used due to specific conditions, one sacroiliac screw fixation in S1 and S2 segments respectively is recommended. No matter which kind of sacroiliac screw is used, if only one screw can be implanted, the fixation in S2 segment is more recommended

  9. Correlation between classification and secondary screw penetration in proximal humeral fractures.

    Directory of Open Access Journals (Sweden)

    Qiuke Wang

    Full Text Available In this study, we investigated the correlation between fracture classification and secondary screw penetration.We retrospectively identified 189 patients with displaced proximal humeral fractures treated by ORIF at our hospital between June 2006 and June 2013. All fractures were classified radiographically before surgery and follow-up for least 2 years after surgery was recommended. At each follow-up, radiographs were taken in three orthogonal views to evaluate secondary screw penetration.The study population consisted of 189 patients. Of these, 70 were male and 119 female, with a mean age of 59.1 years; the mean follow-up time was 28.5 months. Secondary screw penetration occurred in 26 patients. The risk of developing secondary screw penetration was 11.3-fold higher in four-part fractures than two-part fractures (P 0.05.Patients with four-part fractures, type C fractures and medial hinges disruption are vulnerable to secondary screw penetration. This allows additional precautions to be instituted and measures to be taken as needed.

  10. Globalizing carbon lock-in

    International Nuclear Information System (INIS)

    Unruh, Gregory C.; Carrillo-Hermosilla, Javier

    2006-01-01

    This paper extends the arguments surrounding carbon lock-in elaborated in Unruh (Energy Policy 28 (2000) 817; 30 (2002) 317) to countries currently undergoing industrialization. It argues that, for numerous reasons, industrializing countries are unlikely to leapfrog carbon intensive energy development. On the contrary, carbon lock-in may be globalizing and could further constrain climate change mitigation options. It is then argued that many policy recommendations ignore carbon lock-in, possibly limiting their potential for successful implementation. The paper then discusses four policy approaches that appear to have advantages given lock-in conditions. It is recognized, however, that relative ease of implementation does not necessarily equate with superiority. Instead, it is merely a path dependent outcome of past development decisions. Pursuing policies on the basis of relative implementation ease may help address the issue of climate change, but could also result in sub-optimal outcomes along other dimensions of sustainable development

  11. LOCKS AND KEYS SERVICE

    CERN Multimedia

    Locks and Keys Service

    2002-01-01

    The Locks and Keys service (ST/FM) will move from building 55 to building 570 from the 2nd August to the 9th August 2002 included. During this period the service will be closed. Only in case of extreme urgency please call the 164550. Starting from Monday, 12th August, the Locks and Keys Service will continue to follow the activities related to office keys (keys and locks) and will provide the keys for furniture. The service is open from 8h30 to 12h00 and from 13h00 to 17h30. We remind you that your divisional correspondents can help you in the execution of the procedures. We thank you for your comprehension and we remain at your service to help you in solving all the matters related to keys for offices and furniture. Locks and Keys Service - ST Division - FM Group

  12. Percutaneous Iliac Screws for Minimally Invasive Spinal Deformity Surgery

    Directory of Open Access Journals (Sweden)

    Michael Y. Wang

    2012-01-01

    Full Text Available Introduction. Adult spinal deformity (ASD surgeries carry significant morbidity, and this has led many surgeons to apply minimally invasive surgery (MIS techniques to reduce the blood loss, infections, and other peri-operative complications. A spectrum of techniques for MIS correction of ASD has thus evolved, most recently the application of percutaneous iliac screws. Methods. Over an 18 months 10 patients with thoracolumbar scoliosis underwent MIS surgery. The mean age was 73 years (70% females. Patients were treated with multi-level facet osteotomies and interbody fusion using expandable cages followed by percutaneous screw fixation. Percutaneous iliac screws were placed bilaterally using the obturator outlet view to target the ischial body. Results. All patients were successfully instrumented without conversion to an open technique. Mean operative time was 302 minutes and the mean blood loss was 480 cc, with no intraoperative complications. A total of 20 screws were placed successfully as judged by CT scanning to confirm no bony violations. Complications included: two asymptomatic medial breaches at T10 and L5, and one patient requiring delayed epidural hematoma evacuation. Conclusions. Percutaneous iliac screws can be placed safely in patients with ASD. This MIS technique allows for successful caudal anchoring to stress-shield the sacrum and L5-S1 fusion site in long-segment constructs.

  13. Theoretical investigation of flash vaporisation in a screw expander

    Science.gov (United States)

    Vasuthevan, Hanushan; Brümmer, Andreas

    2017-08-01

    In the present study flash vaporisation of liquid injection in a twin screw expander for a Trilateral Flash Cycle (TFC) is examined theoretically. The TFC process comprises a pressure increase in the working fluid, followed by heating the liquid close to boiling point. The hot liquid is injected into the working chamber of a screw expander. During this process the pressure of the liquid drops below the saturation pressure, while the temperature of the liquid remains virtually constant. Hence the liquid is superheated and in a metastable state. The liquid jet seeks to achieve a stable state in thermodynamic equilibrium and is therefore partially vaporised. This effect is referred to as flash vaporisation. Accordingly, a two-phase mixture, consisting of vapour and liquid, exists in the working chamber. Thermodynamic simulations were carried out using water as the working fluid for representative screw expander geometry. The simulations presented are performed from two different aspects during the filling process of a screw expander. The first case is the vaporisation of the injected liquid in a state of thermodynamic equilibrium, whereby the two-phase mixture is treated entirely as a compressible and homogeneous gas. The second case considers flashing efficiency. It describes the quantity of flashed vapour and consists of a liquid and vapour domain. Both models are compared and analysed with respect to the operational behaviour of a screw expander.

  14. Sacroiliac secure corridor: analysis for safe insertion of iliosacral screws

    Directory of Open Access Journals (Sweden)

    Henrique Alves Cruz

    2013-08-01

    Full Text Available OBJECTIVE: Posterior pelvic lesions, especially of the sacral-iliac joint, have high mortality and morbidity risks. Definitive fixation is necessary for the joint stabilization, and one option is the sacral percutaneous pinning with screws. Proximity to important structures to this region brings risks to the fixation procedure; therefore, it is important to know the tridimensional anatomy of the pelvis posterior region. Deviations of the surgeon's hand of four degrees may target the screws to those structures; dimorphisms of the upper sacrum and a poor lesion reduction may redound in a screw malpositioning. This study is aimed to evaluate the dimensions of a safe surgical corridor for safe sacroiliac screw insertion and relations with age and sex of the patients. METHOD: One hundred randomly selected pelvis CTs of patients with no pelvic diseases, seen at a tertiary care teaching Hospital. Measurements were made by computer and the safest area for screw insertion was calculated by two methods. The results were expressed in mm (not in degrees, in order to be a further surgical reference. RESULTS: There was a significant size difference in the analyzed sacral vertebra, differing on a wider size in men than in women. There was no significant statistical difference between vertebral size and age. By both methods, a safe area for screw insertion could be defined. CONCLUSION: Age does not influence the width of the surgical corridor. The surgeon has a safe corridor considered narrower when inserting screws in a female pelvis than when in a male one. However, as the smallest vertebra found (feminine was considered for statics, it was concluded that this corridor is 20 mm wide in any direction, taking as a reference the centrum of the vertebra.

  15. Dorsal bridge plating or transarticular screws for Lisfranc fracture dislocations.

    Science.gov (United States)

    Kirzner, N; Zotov, P; Goldbloom, D; Curry, H; Bedi, H

    2018-04-01

    Aims The aim of this retrospective study was to compare the functional and radiological outcomes of bridge plating, screw fixation, and a combination of both methods for the treatment of Lisfranc fracture dislocations. Patients and Methods A total of 108 patients were treated for a Lisfranc fracture dislocation over a period of nine years. Of these, 38 underwent transarticular screw fixation, 45 dorsal bridge plating, and 25 a combination technique. Injuries were assessed preoperatively according to the Myerson classification system. The outcome measures included the American Orthopaedic Foot and Ankle Society (AOFAS) score, the validated Manchester Oxford Foot Questionnaire (MOXFQ) functional tool, and the radiological Wilppula classification of anatomical reduction. Results Significantly better functional outcomes were seen in the bridge plate group. These patients had a mean AOFAS score of 82.5 points, compared with 71.0 for the screw group and 63.3 for the combination group (p bridge plate group, 38.1 in the screw group, and 45.5 in the combination group (p bridge plating have better functional and radiological outcomes than those treated with transarticular screws or a combination technique. Cite this article: Bone Joint J 2018;100-B:468-74.

  16. Studies on positive conveying in helically channeled single screw extruders

    Directory of Open Access Journals (Sweden)

    L. Pan

    2012-07-01

    Full Text Available A solids conveying theory called double-flight driving theory was proposed for helically channeled single screw extruders. In the extruder, screw channel rotates against static barrel channel, which behaves as cooperative embedded twin-screws for the positive conveying. They turn as two parallel arc plates, between which an arc-plate solid-plug was assumed. By analyzing the forces on the solid-plug in the barrel channel and screw channel, the boundary conditions when the solid-plug is waived of being cut off on barrel wall, were found to have the capacity of the positive conveying. Experimental data were obtained using a specially designed extruder with a helically channeled barrel in the feeding zone and a pressure-adjustable die. The effects of the barrel channel geometry and friction coefficients on the conveying mechanism were presented and compared with the experimental results. The simulations showed that the positive conveying could be achieved after optimizing extruder designs. Compared with the traditional design with the friction-drag conveying, the throughput is higher while screw torque and energy consumption are decreased. Besides, the design criteria of the barrel channel were also discussed.

  17. 49 CFR 236.761 - Locking, electric.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, electric. 236.761 Section 236.761 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, electric. The combination of one or more electric locks and controlling circuits by means of...

  18. 49 CFR 236.105 - Electric lock.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Electric lock. 236.105 Section 236.105 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION...: All Systems Inspections and Tests; All Systems § 236.105 Electric lock. Electric lock, except forced...

  19. Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine.

    Directory of Open Access Journals (Sweden)

    Fei Guo

    Full Text Available Pedicle screw fixation in the upper cervical spine is a difficult and high-risk procedure. The screw is difficult to place rapidly and accurately, and can lead to serious injury of spinal cord or vertebral artery. The aim of this study was to design an individualized 3D printing navigation template for pedicle screw fixation in the upper cervical spine.Using CT thin slices data, we employed computer software to design the navigation template for pedicle screw fixation in the upper cervical spine (atlas and axis. The upper cervical spine models and navigation templates were produced by 3D printer with equal proportion, two sets for each case. In one set (Test group, pedicle screws fixation were guided by the navigation template; in the second set (Control group, the screws were fixed under fluoroscopy. According to the degree of pedicle cortex perforation and whether the screw needed to be refitted, the fixation effects were divided into 3 types: Type I, screw is fully located within the vertebral pedicle; Type II, degree of pedicle cortex perforation is 1 mm or with the poor internal fixation stability and in need of renovation. Type I and Type II were acceptable placements; Type III placements were unacceptable.A total of 19 upper cervical spine and 19 navigation templates were printed, and 37 pedicle screws were fixed in each group. Type I screw-placements in the test group totaled 32; Type II totaled 3; and Type III totaled 2; with an acceptable rate of 94.60%. Type I screw placements in the control group totaled 23; Type II totaled 3; and Type III totaled 11, with an acceptable rate of 70.27%. The acceptability rate in test group was higher than the rate in control group. The operation time and fluoroscopic frequency for each screw were decreased, compared with control group.The individualized 3D printing navigation template for pedicle screw fixation is easy and safe, with a high success rate in the upper cervical spine surgery.

  20. Noninvasive method for retrieval of broken dental implant abutment screw

    Directory of Open Access Journals (Sweden)

    Jagadish Reddy Gooty

    2014-01-01

    Full Text Available Dental implants made of titanium for replacement of missing teeth are widely used because of ease of technical procedure and high success rate, but are not free of complications and may fail. Fracturing of the prosthetic screw continues to be a problem in restorative practice and great challenge to remove the fractured screw conservatively. This case report describes and demonstrates the technique of using an ultrasonic scaler in the removal of the fracture screw fragment as a noninvasive method without damaging the hex of implants.

  1. Design of platform for removing screws from LCD display shields

    Science.gov (United States)

    Tu, Zimei; Qin, Qin; Dou, Jianfang; Zhu, Dongdong

    2017-11-01

    Removing the screws on the sides of a shield is a necessary process in disassembling a computer LCD display. To solve this issue, a platform has been designed for removing the screws on display shields. This platform uses virtual instrument technology with LabVIEW as the development environment to design the mechanical structure with the technologies of motion control, human-computer interaction and target recognition. This platform removes the screws from the sides of the shield of an LCD display mechanically thus to guarantee follow-up separation and recycle.

  2. [Three-dimensional computed tomography analysis and clinical application of sacroiliac screw placement].

    Science.gov (United States)

    Yin, Y C; Zhang, R P; Li, S L; Hou, Z Y; Chen, W; Zhang, Y Z

    2018-03-01

    Objective: To evaluate the possibility of transverse sacroiliac screw placement in different segments of the sacrum. Methods: Data of 80 pelvic CT scans (slice thickness ≤1.0 mm) archived in CT department of the Third Hospital of Hebei Medical University from September 2016 to October 2017 were retrospectively collected. Mimics software was used to rebuild the pelvis three-dimensional model. According to whether the sacral 1(S(1)) segment could place the transverse sacroiliac screws or not, all the sacrums were divided into normal group ( n =55) and dysmorphic group ( n =25). Simulation the S(1), sacral 2(S(2)) transverse sacroiliac screw placement in 3-Matic software. Analysis whether there was any difference in maximum diameter and length of S(2) transverse sacroiliac screw between the normal group and the dysmorphic group. The pelvic CT data of the dysmorphic group were measured, and the optimal tilt angle and length of the oblique S(1) screw were obtained. The feasibility of transverse sacroiliac screw insertion in sacral 3(S(3)) segment was evaluated. t -test, rank sum test, and χ(2) test was used to analyze data, respectively. Results: In the dysmorphic group, the largest diameter of the S(1) transverse screw was (4.9±1.6)mm, and the normal group was (13.6±3.6)mm ( t =-15.07, P =0.00). In the dysmorphic group, the largest diameter of S(2) transverse screw was (13.8±3.0)mm, and was (12.4±2.2)mm in the normal group( t =2.11, P =0.04). There was no significant difference in the length of S(2) transverse sacroiliac screw between the two groups ( t =0.47, P =0.64). In the dysmorphic group, the anterior vertebral height of S(1) was (23.1±4.0)mm, which was significantly higher than that of the normal group ((14.1±4.2)mm)( t =9.01, P =0.00). The angle of S(1)S(2) in the dysmorphic group was 10.9°(3.8°, 17.6°), which was significantly larger than that of the normal group (2.0°(1.0°, 2.0°) ( Z =-4.03, P =0.00). In the dysmorphic group, the incline angle

  3. Assessing carbon lock-in

    International Nuclear Information System (INIS)

    Erickson, Peter; Kartha, Sivan; Lazarus, Michael; Tempest, Kevin

    2015-01-01

    The term ‘carbon lock-in’ refers to the tendency for certain carbon-intensive technological systems to persist over time, ‘locking out’ lower-carbon alternatives, and owing to a combination of linked technical, economic, and institutional factors. These technologies may be costly to build, but relatively inexpensive to operate and, over time, they reinforce political, market, and social factors that make it difficult to move away from, or ‘unlock’ them. As a result, by investing in assets prone to lock-in, planners and investors restrict future flexibility and increase the costs of achieving agreed climate protection goals. Here, we develop a straight-forward approach to assess the speed, strength, and scale of carbon lock-in for major energy-consuming assets in the power, buildings, industry, and transport sectors. We pilot the approach at the global level, finding that carbon lock-in is greatest, globally, for coal power plants, gas power plants, and oil-based vehicles. The approach can be readily applied at the national or regional scale, and may be of particular relevance to policymakers interested in enhancing flexibility in their jurisdictions for deeper emissions cuts in the future, and therefore in limiting the future costs associated with ‘stranded assets’. (letter)

  4. ACHP | Unified Federal Review

    Science.gov (United States)

    Search skip specific nav links Home arrow Unified Federal Review Three logos: 1) Executive Office of the Homeland Security. Unified Federal Environmental and Historic Preservation Review Process Please visit the new location for the Unified Federal Review located here: http://www.fema.gov/environmental-historic

  5. Phase-locked Josephson soliton oscillators

    DEFF Research Database (Denmark)

    Holst, T.; Hansen, Jørn Bindslev; Grønbech-Jensen, N.

    1991-01-01

    Detailed experimental characterization of the phase-locking at both DC and at microwave frequencies is presented for two closely spaced Josephson soliton (fluxon) oscillators. In the phase-locked state, the radiated microwave power exhibited an effective gain. With one common bias source......, a frequency tunability of the phase-locked oscillators up to 7% at 10 GHz was observed. The interacting soliton oscillators were modeled by two inductively coupled nonlinear transmission lines...

  6. Micro-CT evaluation and histological analysis of screw-bone interface of expansive pedicle screw in osteoporotic sheep.

    Science.gov (United States)

    Wan, Shi-yong; Lei, Wei; Wu, Zi-xiang; Lv, Rong; Wang, Jun; Fu, Suo-chao; Li, Bo; Zhan, Ce

    2008-04-01

    To investigate the properties of screw-bone interface of expansive pedicle screw (EPS) in osteoporotic sheep by micro-CT and histological observation. Six female sheep with bilateral ovariectomy-induced osteoporosis were employed in this experiment. After EPS insertion in each femoral condyle, the sheep were randomly divided into two groups: 3 sheep were bred for 3 months (Group A), while the other 3 were bred for 6 months (Group B). After the animals being killed, the femoral condyles with EPS were obtained, which were three-dimensionally-imaged and reconstructed by micro-CT. Histological evaluation was made thereafter. The trabecular microstructure was denser at the screw-bone interface than in the distant parts in expansive section, especially within the spiral marking. In the non-expansive section, however, there was no significant difference between the interface and the distant parts. The regions of interest (ROI) adjacent to EPS were reconstructed and analyzed by micro-CT with the same thresholds. The three-dimensional (3-D) parameters, including tissue mineral density (TMD), bone volume fraction (BVF, BV/TV), bone surface/bone volume (BS/BV) ratio, trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp), were significantly better in expansive sections than non-expansive sections (P less than 0.05). Histologically, newly-formed bony trabeculae crawled along the expansive fissures and into the center of EPS. The newly-formed bones, as well as the bones at the bone-screw interface, closely contacted with the EPS and constructed four compartments. The findings of the current study, based on micro-CT and histological evaluation, suggest that EPS can significantly provide stabilization in osteoporotic cancellous bones.

  7. Stress corrosion cracking life estimation of hold-down spring screw for nuclear fuel assembly

    International Nuclear Information System (INIS)

    Koh, S.K.

    2005-01-01

    Hold-down spring screw fractures due to primary water stress corrosion cracking were observed in nuclear fuel assemblies. The screw fastens hold-down springs that are required to maintain the nuclear fuel assembly in contact with upper core plate and permit thermal and irradiation-induced length changes. In order to investigate the primary causes of the screw fractures, the finite element stress analysis and fracture mechanics analysis were performed on the hold-down spring assembly. The elastic-plastic finite element analysis showed that the local stresses at the critical regions of head-shank fillet and thread root significantly exceeded the yield strength of the screw material, resulting in local plastic deformation. Preloading on the screw applied for tightening had beneficial effects on the screw strength by reducing the stress level at the critical regions, compared to the screw without preload. Calculated deflections and strains at the hold-down springs using the finite element analysis were in very close agreements with the experimentally measured deflections and strains. Primary water stress corrosion cracking (PWSCC) life of the Inconel 600 screw was predicted by integrating the Scott's model and resulted in a life of 1.42 years, which was fairly close to the field experience. Cracks were expected to originate at the threaded region of the screw and propagated to the opposite side of the spring, which was confirmed by the fractographic analysis of the fractured screws. (orig.)

  8. Biomechanical Comparison of External Fixation and Compression Screws for Transverse Tarsal Joint Arthrodesis.

    Science.gov (United States)

    Latt, L Daniel; Glisson, Richard R; Adams, Samuel B; Schuh, Reinhard; Narron, John A; Easley, Mark E

    2015-10-01

    Transverse tarsal joint arthrodesis is commonly performed in the operative treatment of hindfoot arthritis and acquired flatfoot deformity. While fixation is typically achieved using screws, failure to obtain and maintain joint compression sometimes occurs, potentially leading to nonunion. External fixation is an alternate method of achieving arthrodesis site compression and has the advantage of allowing postoperative compression adjustment when necessary. However, its performance relative to standard screw fixation has not been quantified in this application. We hypothesized that external fixation could provide transverse tarsal joint compression exceeding that possible with screw fixation. Transverse tarsal joint fixation was performed sequentially, first with a circular external fixator and then with compression screws, on 9 fresh-frozen cadaveric legs. The external fixator was attached in abutting rings fixed to the tibia and the hindfoot and a third anterior ring parallel to the hindfoot ring using transverse wires and half-pins in the tibial diaphysis, calcaneus, and metatarsals. Screw fixation comprised two 4.3 mm headless compression screws traversing the talonavicular joint and 1 across the calcaneocuboid joint. Compressive forces generated during incremental fixator foot ring displacement to 20 mm and incremental screw tightening were measured using a custom-fabricated instrumented miniature external fixator spanning the transverse tarsal joint. The maximum compressive force generated by the external fixator averaged 186% of that produced by the screws (range, 104%-391%). Fixator compression surpassed that obtainable with screws at 12 mm of ring displacement and decreased when the tibial ring was detached. No correlation was found between bone density and the compressive force achievable by either fusion method. The compression across the transverse tarsal joint that can be obtained with a circular external fixator including a tibial ring exceeds that

  9. Mini-Fragment Fixation Is Equivalent to Bicortical Screw Fixation for Horizontal Medial Malleolus Fractures.

    Science.gov (United States)

    Wegner, Adam M; Wolinsky, Philip R; Robbins, Michael A; Garcia, Tanya C; Amanatullah, Derek F

    2018-05-01

    Horizontal fractures of the medial malleolus occur through application of valgus or abduction force through the ankle that creates a tension failure of the medial malleolus. The authors hypothesize that mini-fragment T-plates may offer improved fixation, but the optimal fixation construct for these fractures remains unclear. Forty synthetic distal tibiae with identical osteotomies were randomized into 4 fixation constructs: (1) two parallel unicortical cancellous screws; (2) two parallel bicortical cortical screws; (3) a contoured mini-fragment T-plate with 2 unicortical screws in the fragment and 2 bicortical screws in the shaft; and (4) a contoured mini-fragment T-plate with 2 bicortical screws in the fragment and 2 unicortical screws in the shaft. Specimens were subjected to offset axial tension loading on a servohydraulic testing system and tracked using high-resolution video. Failure was defined as 2 mm of articular displacement. Analysis of variance followed by a Tukey-Kramer post hoc test was used to assess for differences between groups, with significance defined as Pfragment T-plate constructs (239±83 N/mm and 190±37 N/mm) and the bicortical screw construct (240±17 N/mm) were not statistically different. The mean stiffness values of both mini-fragment T-plate constructs and the bicortical screw construct were higher than that of a parallel unicortical screw construct (102±20 N/mm). Contoured T-plate constructs provide stiffer initial fixation than a unicortical cancellous screw construct. The T-plate is biomechanically equivalent to a bicortical screw construct, but may be superior in capturing small fragments of bone. [Orthopedics. 2018; 41(3):e395-e399.]. Copyright 2018, SLACK Incorporated.

  10. Repair of microdamage in osteonal cortical bone adjacent to bone screw.

    Directory of Open Access Journals (Sweden)

    Lei Wang

    Full Text Available Up to date, little is known about the repair mode of microdamage in osteonal cortical bone resulting from bone screw implantation. In this study, self-tapping titanium cortical bone screws were inserted into the tibial diaphyses of 24 adult male rabbits. The animals were sacrificed at 1 day, 2 weeks, 1 month and 2 months after surgery. Histomorphometric measurement and confocal microscopy were performed on basic fuchsin stained bone sections to examine the morphological characteristics of microdamage, bone resorption activity and spatial relationship between microdamage and bone resorption. Diffuse and linear cracks were coexisted in peri-screw bone. Intracortical bone resorption was significantly increased 2 weeks after screw installation and reach to the maximum at 1 month. There was no significant difference in bone resorption between 1-month and 2-months groups. Microdamage was significantly decreased within 1 month after surgery. Bone resorption was predisposed to occur in the region of <100 µm from the bone-screw interface, where had extensive diffuse damage mixed with linear cracks. Different patterns of resorption cavities appeared in peri-screw bone. These data suggest that 1 the complex microdamage composed of diffuse damage and linear cracks is a strong stimulator for initiating targeted bone remodeling; 2 bone resorption activities taking place on the surfaces of differently oriented Haversian and Volkmann canals work in a team for the repair of extensive microdamage; 3 targeted bone remodeling is a short-term reaction to microdamage and thereby it may not be able to remove all microdamage resulting from bone screw insertion.

  11. Breaking Carbon Lock-in

    DEFF Research Database (Denmark)

    Driscoll, Patrick Arthur

    2014-01-01

    This central focus of this paper is to highlight the ways in which path dependencies and increasing returns (network effects) serve to reinforce carbon lock-in in large-scale road transportation infrastructure projects. Breaking carbon lock-in requires drastic changes in the way we plan future...

  12. A photovoltaic module diagnostic setup for lock-in-thermography and lock-in electroluminescence imaging

    DEFF Research Database (Denmark)

    Parikh, Harsh; Spataru, Sergiu; Sera, Dezso

    2018-01-01

    Electroluminescence (EL) imaging and infrared (IRT) thermography techniques have become indispensable tools in recent years for health diagnostic of PV modules in solar industry application. Complementary to these imaging methods, lock-in techniques can effectively remove noise by periodically...... modulating the input signal and averaging it over a desired number of periods. We propose a combined lock-in EL and lock-in IRT diagnostic setup for accurate analysis of different types of faults occurring in a solar module. The setup is built around a Goldeye CL-033 high-speed SWIR camera, which can acquire...... experimental work on a (36/72) cell solar module using combined (EL) or (IRT) lock-in-thermography. The setup allows one to investigate the different technological problems that can occur when performing PV diagnostics in drone-based inspections....

  13. The use of blocking screws with internal lengthening nail and reverse rule of thumb for blocking screws in limb lengthening and deformity correction surgery

    Directory of Open Access Journals (Sweden)

    Saravanaraja Muthusamy

    2016-09-01

    Full Text Available Abstract Internal lengthening nail (ILN is a recent development in limb lengthening and deformity correction specialty. The ILN has the distinct advantage of combining acute deformity correction with gradual lengthening of bone. While using ILN, the short metaphyseal bone fragment may develop a deformity at the time of osteotomy and nail insertion or during bone lengthening because of the wide medullary canal. These deformities are typically predictable, and blocking screws (Poller screws are helpful in these situations. This manuscript describes the common deformities that occur in femur and tibia with osteotomies at different locations while using ILN in antegrade and retrograde nailing technique. Also, a systematic approach to the appropriate use of blocking screws in these deformities is described. In addition, the “reverse rule of thumb” is introduced as a quick reference to determine the ideal location(s and number of blocking screws. These principles are applicable to limb lengthening and deformity correction as well as fracture fixation using intramedullary nails.

  14. The use of blocking screws with internal lengthening nail and reverse rule of thumb for blocking screws in limb lengthening and deformity correction surgery.

    Science.gov (United States)

    Muthusamy, Saravanaraja; Rozbruch, S Robert; Fragomen, Austin T

    2016-11-01

    Internal lengthening nail (ILN) is a recent development in limb lengthening and deformity correction specialty. The ILN has the distinct advantage of combining acute deformity correction with gradual lengthening of bone. While using ILN, the short metaphyseal bone fragment may develop a deformity at the time of osteotomy and nail insertion or during bone lengthening because of the wide medullary canal. These deformities are typically predictable, and blocking screws (Poller screws) are helpful in these situations. This manuscript describes the common deformities that occur in femur and tibia with osteotomies at different locations while using ILN in antegrade and retrograde nailing technique. Also, a systematic approach to the appropriate use of blocking screws in these deformities is described. In addition, the "reverse rule of thumb" is introduced as a quick reference to determine the ideal location(s) and number of blocking screws. These principles are applicable to limb lengthening and deformity correction as well as fracture fixation using intramedullary nails.

  15. 49 CFR 236.705 - Bar, locking.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Bar, locking. 236.705 Section 236.705..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.705 Bar, locking. A bar in an interlocking machine to which the locking dogs are attached. ...

  16. 49 CFR 236.768 - Locking, time.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, time. 236.768 Section 236.768... Locking, time. A method of locking, either mechanical or electrical, which, after a signal has been caused to display an aspect to proceed, prevents, until after the expiration of a predetermined time...

  17. Phase locking between Josephson soliton oscillators

    DEFF Research Database (Denmark)

    Holst, T.; Hansen, Jørn Bindslev; Grønbech-Jensen, N.

    1990-01-01

    We report observations of phase-locking phenomena between two Josephson soliton (fluxon) oscillators biased in self-resonant modes. The locking strength was measured as a function of bias conditions. A frequency tunability of the phase-locked oscillators up to 7% at 10 GHz was observed. Two coupled...... perturbed sine-Gordon equations were derived from an equivalent circuit consisting of inductively coupled, nonlinear, lossy transmission lines. These equations were solved numerically to find the locking regions. Good qualitative agreement was found between the experimental results and the calculations...

  18. Low-power wide-locking-range injection-locked frequency divider for OFDM UWB systems

    Energy Technology Data Exchange (ETDEWEB)

    Yin Jiangwei; Li Ning; Zheng Renliang; Li Wei; Ren Junyan, E-mail: lining@fudan.edu.c [State Key Laboratory of ASIC and System, Fudan University, Shanghai 201203 (China)

    2009-05-01

    This paper describes a divide-by-two injection-locked frequency divider (ILFD) for frequency synthesizers as used in multiband orthogonal frequency division multiplexing (OFDM) ultra-wideband (UWB) systems. By means of dual-injection technique and other conventional tuning techniques, such as DCCA and varactor tuning, the divider demonstrates a wide locking range while consuming much less power. The chip was fabricated in the Jazz 0.18 mum RF CMOS process. The measurement results show that the divider achieves a locking range of 4.85 GHz (6.23 to 11.08 GHz) at an input power of 8 dBm. The core circuit without the test buffer consumes only 3.7 mA from a 1.8 V power supply and has a die area of 0.38 x 0.28 mm{sup 2}. The wide locking range combined with low power consumption makes the ILFD suitable for its application in UWB systems.

  19. Low-power wide-locking-range injection-locked frequency divider for OFDM UWB systems

    International Nuclear Information System (INIS)

    Yin Jiangwei; Li Ning; Zheng Renliang; Li Wei; Ren Junyan

    2009-01-01

    This paper describes a divide-by-two injection-locked frequency divider (ILFD) for frequency synthesizers as used in multiband orthogonal frequency division multiplexing (OFDM) ultra-wideband (UWB) systems. By means of dual-injection technique and other conventional tuning techniques, such as DCCA and varactor tuning, the divider demonstrates a wide locking range while consuming much less power. The chip was fabricated in the Jazz 0.18 μm RF CMOS process. The measurement results show that the divider achieves a locking range of 4.85 GHz (6.23 to 11.08 GHz) at an input power of 8 dBm. The core circuit without the test buffer consumes only 3.7 mA from a 1.8 V power supply and has a die area of 0.38 x 0.28 mm 2 . The wide locking range combined with low power consumption makes the ILFD suitable for its application in UWB systems.

  20. Self-locking degree-4 vertex origami structures.

    Science.gov (United States)

    Fang, Hongbin; Li, Suyi; Wang, K W

    2016-11-01

    A generic degree-4 vertex (4-vertex) origami possesses one continuous degree-of-freedom for rigid folding, and this folding process can be stopped when two of its facets bind together. Such facet-binding will induce self-locking so that the overall structure stays at a pre-specified configuration without additional locking elements or actuators. Self-locking offers many promising properties, such as programmable deformation ranges and piecewise stiffness jumps, that could significantly advance many adaptive structural systems. However, despite its excellent potential, the origami self-locking features have not been well studied, understood, and used. To advance the state of the art, this research conducts a comprehensive investigation on the principles of achieving and harnessing self-locking in 4-vertex origami structures. Especially, for the first time, this study expands the 4-vertex structure construction from single-component to dual-component designs and investigates their self-locking behaviours. By exploiting various tessellation designs, this research discovers that the dual-component designs offer the origami structures with extraordinary attributes that the single-component structures do not have, which include the existence of flat-folded locking planes, programmable locking points and deformability. Finally, proof-of-concept experiments investigate how self-locking can effectively induce piecewise stiffness jumps. The results of this research provide new scientific knowledge and a systematic framework for the design, analysis and utilization of self-locking origami structures for many potential engineering applications.

  1. Research on energy conversion mechanism of a screw centrifugal pump under the water

    International Nuclear Information System (INIS)

    Quan, H; Li, R N; Han, W; Cheng, X R; Shen, Z J; Su, Q M

    2013-01-01

    In order to research screw centrifugal pump impeller power capability and energy conversion mechanism, we used Navier-Stokes equation and standard k-ε equation turbulence model on the basis of the Euler equations to carry out screw centrifugal pump internal flow numerical simulation. This was explored by simulating specific design conditions; the medium is water, variation of speed and pressure of flow filed under the action of the impeller, and the screw centrifugal impeller shroud line and wheel line segment take monitoring sites. The monitoring points are between dynamic head and static head change to analyze the energy conversion capability along the impeller corners of screw centrifugal pump. The results show that the energy of fluid of the screw centrifugal pump is provided by spiral segment, the spiral segment in front of the impeller has played a multi-level role, it has significant reference value to research the energy conversion mechanism of screw centrifugal pump under solid-liquid two phase

  2. Posterior pelvic ring fractures: Closed reduction and percutaneous CT-guided sacroiliac screw fixation

    International Nuclear Information System (INIS)

    Jacob, Augustinus Ludwig; Messmer, Peter; Stock, Klaus-Wilhelm; Suhm, Norbert; Baumann, Bernard; Regazzoni, Pietro; Steinbrich, Wolfgang

    1997-01-01

    Purpose. To assess the midterm results of closed reduction and percutaneous fixation (CRPF) with computed tomography (CT)-guided sacroiliac screw fixation in longitudinal posterior pelvic ring fractures. Methods. Thirteen patients with 15 fractures were treated. Eleven patients received a unilateral, two a bilateral, screw fixation. Twenty-seven screws were implanted. Continuous on-table traction was used in six cases. Mean radiological follow-up was 13 months. Results. Twenty-five (93%) screws were placed correctly. There was no impingement of screws on neurovascular structures. Union occurred in 12 (80%), delayed union in 2 (13%), and nonunion in 1 of 15 (7%) fractures. There was one screw breakage and two axial dislocations. Conclusion. Sacroiliac CRPF of longitudinal fractures of the posterior pelvic ring is technically simple, minimally invasive, well localized, and stable. It should be done by an interventional/surgical team. CT is an excellent guiding modality. Closed reduction may be a problem and succeeds best when performed as early as possible

  3. The Peierls stress of the moving [Formula: see text] screw dislocation in Ta.

    Science.gov (United States)

    Liu, Ruiping; Wang, Shaofeng; Wu, Xiaozhi

    2009-08-26

    The Peierls stress of the moving [Formula: see text] screw dislocation with a planar and non-dissociated core structure in Ta has been calculated. The elastic strain energy which is associated with the discrete effect of the lattice and ignored in classical Peierls-Nabarro (P-N) theory has been taken into account in calculating the Peierls stress, and it can make the Peierls stress become smaller. The Peierls stress we obtain is very close to the experimental data. As shown in the numerical calculations and atomistic simulations, the core structure of the screw dislocation undergoes significant changes under the explicit stress before the screw dislocation moves. Moreover, the mechanism of the screw dislocation is revealed by our results and the experimental data that the screw dislocation retracts its extension in three {110} planes and transforms its dissociated core structure into a planar configuration. Therefore, the core structure of the moving [Formula: see text] screw dislocation in Ta is proposed to be planar.

  4. The Peierls stress of the moving 1/2{110} screw dislocation in Ta

    International Nuclear Information System (INIS)

    Liu Ruiping; Wang Shaofeng; Wu Xiaozhi

    2009-01-01

    The Peierls stress of the moving 1/2 {110} screw dislocation with a planar and non-dissociated core structure in Ta has been calculated. The elastic strain energy which is associated with the discrete effect of the lattice and ignored in classical Peierls-Nabarro (P-N) theory has been taken into account in calculating the Peierls stress, and it can make the Peierls stress become smaller. The Peierls stress we obtain is very close to the experimental data. As shown in the numerical calculations and atomistic simulations, the core structure of the screw dislocation undergoes significant changes under the explicit stress before the screw dislocation moves. Moreover, the mechanism of the screw dislocation is revealed by our results and the experimental data that the screw dislocation retracts its extension in three {110} planes and transforms its dissociated core structure into a planar configuration. Therefore, the core structure of the moving 1/2 {110} screw dislocation in Ta is proposed to be planar.

  5. Optical double-locked semiconductor lasers

    Science.gov (United States)

    AlMulla, Mohammad

    2018-06-01

    Self-sustained period-one (P1) nonlinear dynamics of a semiconductor laser are investigated when both optical injection and modulation are applied for stable microwave frequency generation. Locking the P1 oscillation through modulation on the bias current, injection strength, or detuning frequency stabilizes the P1 oscillation. Through the phase noise variance, the different modulation types are compared. It is demonstrated that locking the P1 oscillation through optical modulation on the output of the master laser outperforms bias-current modulation of the slave laser. Master laser modulation shows wider P1-oscillation locking range and lower phase noise variance. The locking characteristics of the P1 oscillation also depend on the operating conditions of the optical injection system

  6. Bicycle Parking and Locking

    DEFF Research Database (Denmark)

    Larsen, Jonas

    2017-01-01

    . This article contributes with new insights into parking and locking - ‘moorings’ - to cycling literature. It presents an ethnography of ‘design moorings’ and practices associated with parking and locking bikes. The main case study is the very pro-cycling city of Copenhagen. Yet to explore what is unique about...

  7. Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine.

    Science.gov (United States)

    Guo, Fei; Dai, Jianhao; Zhang, Junxiang; Ma, Yichuan; Zhu, Guanghui; Shen, Junjie; Niu, Guoqi

    2017-01-01

    Pedicle screw fixation in the upper cervical spine is a difficult and high-risk procedure. The screw is difficult to place rapidly and accurately, and can lead to serious injury of spinal cord or vertebral artery. The aim of this study was to design an individualized 3D printing navigation template for pedicle screw fixation in the upper cervical spine. Using CT thin slices data, we employed computer software to design the navigation template for pedicle screw fixation in the upper cervical spine (atlas and axis). The upper cervical spine models and navigation templates were produced by 3D printer with equal proportion, two sets for each case. In one set (Test group), pedicle screws fixation were guided by the navigation template; in the second set (Control group), the screws were fixed under fluoroscopy. According to the degree of pedicle cortex perforation and whether the screw needed to be refitted, the fixation effects were divided into 3 types: Type I, screw is fully located within the vertebral pedicle; Type II, degree of pedicle cortex perforation is stability and no need to renovate; Type III, degree of pedicle cortex perforation is >1 mm or with the poor internal fixation stability and in need of renovation. Type I and Type II were acceptable placements; Type III placements were unacceptable. A total of 19 upper cervical spine and 19 navigation templates were printed, and 37 pedicle screws were fixed in each group. Type I screw-placements in the test group totaled 32; Type II totaled 3; and Type III totaled 2; with an acceptable rate of 94.60%. Type I screw placements in the control group totaled 23; Type II totaled 3; and Type III totaled 11, with an acceptable rate of 70.27%. The acceptability rate in test group was higher than the rate in control group. The operation time and fluoroscopic frequency for each screw were decreased, compared with control group. The individualized 3D printing navigation template for pedicle screw fixation is easy and safe

  8. Comparison of the Pullout Strength of Different Pedicle Screw Designs and Augmentation Techniques in an Osteoporotic Bone Model.

    Science.gov (United States)

    Kiyak, Gorkem; Balikci, Tevfik; Heydar, Ahmed Majid; Bezer, Murat

    2018-02-01

    Mechanical study. To compare the pullout strength of different screw designs and augmentation techniques in an osteoporotic bone model. Adequate bone screw pullout strength is a common problem among osteoporotic patients. Various screw designs and augmentation techniques have been developed to improve the biomechanical characteristics of the bone-screw interface. Polyurethane blocks were used to mimic human osteoporotic cancellous bone, and six different screw designs were tested. Five standard and expandable screws without augmentation, eight expandable screws with polymethylmethacrylate (PMMA) or calcium phosphate augmentation, and distal cannulated screws with PMMA and calcium phosphate augmentation were tested. Mechanical tests were performed on 10 unused new screws of each group. Screws with or without augmentation were inserted in a block that was held in a fixture frame, and a longitudinal extraction force was applied to the screw head at a loading rate of 5 mm/min. Maximum load was recorded in a load displacement curve. The peak pullout force of all tested screws with or without augmentation was significantly greater than that of the standard pedicle screw. The greatest pullout force was observed with 40-mm expandable pedicle screws with four fins and PMMA augmentation. Augmented distal cannulated screws did not have a greater peak pullout force than nonaugmented expandable screws. PMMA augmentation provided a greater peak pullout force than calcium phosphate augmentation. Expandable pedicle screws had greater peak pullout forces than standard pedicle screws and had the advantage of augmentation with either PMMA or calcium phosphate cement. Although calcium phosphate cement is biodegradable, osteoconductive, and nonexothermic, PMMA provided a significantly greater peak pullout force. PMMA-augmented expandable 40-mm four-fin pedicle screws had the greatest peak pullout force.

  9. Screw-vector bond graphs for kinetic-static modelling and analysis of mechanisms

    International Nuclear Information System (INIS)

    Bidard, Catherine

    1994-01-01

    This dissertation deals with the kinetic-static modelling and analysis of spatial mechanisms used in robotics systems. A framework is proposed, which embodies a geometrical and a network approach for kinetic-static modelling. For this purpose we use screw theory and bond graphs. A new form of bond graphs is introduced: the screw-vector bond graph, whose power variables are defined to be wrenches and twists expressed as intrinsic screw-vectors. The mechanism is then identified as a network, whose components are kinematic pairs and whose topology is described by a directed graph. A screw-vector Simple Junction Structure represents the topological constraints. Kinematic pairs are represented by one-port elements, defined by two reciprocal screw-vector spaces. Using dual bases of screw-vectors, a generic decomposition of kinematic pair elements is given. The reduction of kinetic-static models of series and parallel kinematic chains is used in order to derive kinetic-static functional models in geometric form. Thereupon, the computational causality assignment is adapted for the graphical analysis of the mobility and the functioning of spatial mechanisms, based on completely or incompletely specified models. (author) [fr

  10. Cement Augmentation in Sacroiliac Screw Fixation Offers Modest Biomechanical Advantages in a Cadaver Model.

    Science.gov (United States)

    Osterhoff, Georg; Dodd, Andrew E; Unno, Florence; Wong, Angus; Amiri, Shahram; Lefaivre, Kelly A; Guy, Pierre

    2016-11-01

    Sacroiliac screw fixation in elderly patients with pelvic fractures is prone to failure owing to impaired bone quality. Cement augmentation has been proposed as a possible solution, because in other anatomic areas this has been shown to reduce screw loosening. However, to our knowledge, this has not been evaluated for sacroiliac screws. We investigated the potential biomechanical benefit of cement augmentation of sacroiliac screw fixation in a cadaver model of osteoporotic bone, specifically with respect to screw loosening, construct survival, and fracture-site motion. Standardized complete sacral ala fractures with intact posterior ligaments in combination with ipsilateral upper and lower pubic rami fractures were created in osteoporotic cadaver pelves and stabilized by three fixation techniques: sacroiliac (n = 5) with sacroiliac screws in S1 and S2, cemented (n = 5) with addition of cement augmentation, and transsacral (n = 5) with a single transsacral screw in S1. A cyclic loading protocol was applied with torque (1.5 Nm) and increasing axial force (250-750 N). Screw loosening, construct survival, and sacral fracture-site motion were measured by optoelectric motion tracking. A sample-size calculation revealed five samples per group to be required to achieve a power of 0.80 to detect 50% reduction in screw loosening. Screw motion in relation to the sacrum during loading with 250 N/1.5 Nm was not different among the three groups (sacroiliac: 1.2 mm, range, 0.6-1.9; cemented: 0.7 mm, range, 0.5-1.3; transsacral: 1.1 mm, range, 0.6-2.3) (p = 0.940). Screw subsidence was less in the cemented group (3.0 mm, range, 1.2-3.7) compared with the sacroiliac (5.7 mm, range, 4.7-10.4) or transsacral group (5.6 mm, range, 3.8-10.5) (p = 0.031). There was no difference with the numbers available in the median number of cycles needed until failure; this was 2921 cycles (range, 2586-5450) in the cemented group, 2570 cycles (range, 2500-5107) for the sacroiliac specimens, and

  11. 49 CFR 236.757 - Lock, electric.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Lock, electric. 236.757 Section 236.757... Lock, electric. A device to prevent or restrict the movement of a lever, a switch or a movable bridge, unless the locking member is withdrawn by an electrical device, such as an electromagnet, solenoid or...

  12. Newly designed anterolateral and posterolateral locking anatomic plates for lateral tibial plateau fractures: a finite element study.

    Science.gov (United States)

    Chen, Pengbo; Lu, Hua; Shen, Hao; Wang, Wei; Ni, Binbin; Chen, Jishizhan

    2017-02-23

    Lateral column tibial plateau fracture fixation with a locking screw plate has higher mechanical stability than other fixation methods. The objectives of the present study were to introduce two newly designed locking anatomic plates for lateral tibial plateau fracture and to demonstrate their characteristics of the fixation complexes under the axial loads. Three different 3D finite element models of the lateral tibial plateau fracture with the bone plates were created. Various axial forces (100, 500, 1000, and 1500 N) were applied to simulate the axial compressive load on an adult knee during daily life. The equivalent maps of displacement and stress were output, and relative displacement was calculated along the fracture lines. The displacement and stresses in the fixation complexes increased with the axial force. The equivalent displacement or stress map of each fixation under different axial forces showed similar distributing characteristics. The motion characteristics of the three models differed, and the max-shear stress of trabecula increased with the axial load. These two novel plates could fix lateral tibial plateau fractures involving anterolateral and posterolateral fragments. Motions after open reduction and stable internal fixation should be advised to decrease the risk of trabecular microfracture. The relative displacement of the posterolateral fragments is different when using anterolateral plate and posterolateral plate, which should be considered in choosing the implants for different posterolateral plateau fractures.

  13. Evaluation of two styles of slotted, flat-head screws

    International Nuclear Information System (INIS)

    Reeves, C.A. Jr.; Johnson, W.B.

    1979-01-01

    A series of torque tests were performed to evaluate the relative merits of two different flat-head screws fabricated from a uranium--6% niobium alloy. The screws tested were machined with both normal, straight-through slots in the head and with slots having radiused bottoms. Test results indicate that both designs easily surpass the required 20-inch-pound-proof torque

  14. Covering the screw-access holes of implant restorations in the esthetic zone: a clinical report.

    Directory of Open Access Journals (Sweden)

    Abolfazl Saboury

    2014-12-01

    Full Text Available Screw-retained implant restorations have an advantage of predictable retention as well as retrievability, and obviate the risk of excessive sub-gingival cement commonly associated with cement retained implant restorations. Screw-retained restorations generally have screw access holes, which can compromise esthetics and weaken the porcelain around the holes. The purpose of this study is to describe the use of a separate overcasting crown design to cover the screw access hole of implant screw-retained prosthesis for improved esthetics.

  15. Screw-System-Based Mobility Analysis of a Family of Fully Translational Parallel Manipulators

    Directory of Open Access Journals (Sweden)

    Ernesto Rodriguez-Leal

    2013-01-01

    Full Text Available This paper investigates the mobility of a family of fully translational parallel manipulators based on screw system analysis by identifying the common constraint and redundant constraints, providing a case study of this approach. The paper presents the branch motion-screws for the 3-RP̲C-Y parallel manipulator, the 3-RCC-Y (or 3-RP̲RC-Y parallel manipulator, and a newly proposed 3-RP̲C-T parallel manipulator. Then the paper determines the sets of platform constraint-screws for each of these three manipulators. The constraints exerted on the platforms of the 3-RP̲C architectures and the 3-RCC-Y manipulators are analyzed using the screw system approach and have been identified as couples. A similarity has been identified with the axes of couples: they are perpendicular to the R joint axes, but in the former the axes are coplanar with the base and in the latter the axes are perpendicular to the limb. The remaining couples act about the axis that is normal to the base. The motion-screw system and constraint-screw system analysis leads to the insightful understanding of the mobility of the platform that is then obtained by determining the reciprocal screws to the platform constraint screw sets, resulting in three independent instantaneous translational degrees-of-freedom. To validate the mobility analysis of the three parallel manipulators, the paper includes motion simulations which use a commercially available kinematics software.

  16. Robust tilt and lock mechanism for hopping actuator

    Energy Technology Data Exchange (ETDEWEB)

    Salton, Jonathan R.; Buerger, Stephen; Dullea, Kevin J.; Marron, Lisa C.; Salisbury, Curt Michael; Spletzer, Barry Louis

    2017-02-07

    A tilt and lock apparatus that includes a tilt servomechanism, a spiral torsion spring, a lock wheel, and a lock hook is described herein. The spiral torsion spring is mechanically coupled to the tilt servomechanism and the lock wheel (which includes an opening). When a shaft is positioned through the opening, rotation of the lock wheel is in unison with rotation of the shaft. An external surface of the lock wheel includes one or more grooves. The lock hook includes a head that engages and disengages the grooves. The lock wheel is stationary when the head engages one of the grooves and is rotatable when the head disengages the grooves. The head and the grooves are geometrically aligned when engaged to prevent creation of a force that acts to disengage the head responsive to an applied force acting on the shaft.

  17. Intraoperative insertion torque of lumbar pedicle screw and postoperative radiographic evaluation. Short-term observation

    International Nuclear Information System (INIS)

    Mizuno, Koichi; Shinomiya, Kenichi; Otani, Kazuyuki

    2005-01-01

    The correlation between the insertion torque of a lumbar pedicle screw and the mechanical stability of the screw in the bone has been mentioned in in vitro studies. The purpose of this study was to confirm the factors affecting the insertion torque of such screws in vivo. Also, the contribution of insertion torque to the initial stability of the fusion area was to be analyzed in vivo. A series of 23 cases representing 50 lumbar vertebrae were included in this study, in which we examined bone mineral density using quantitative computed tomography (CT) prior to operation. Two screw shapes were utilized, with the insertion torque for each screw measured at two points in time. The correlation between insertion torque and mineral density was investigated. Screw positions were confirmed on postoperative CT scans, and the effect of the screw thread cutting into the cortex bone was investigated. Radiographic changes at three points during a period of 3 months were also measured, and we then evaluated the interrelations between these changes and insertion torque. Furthermore, the relation between insertion torque and instability at 3 months was investigated. Correlations of insertion torque and bone mineral density depended on screw shape. There was no correlation found with mineral density in the case of cylindrical screws. Insertion torque was not affected by the screw thread cutting into the cortex of bone. As for postoperative alignment changes, no definitive trends could be ascertained, and no interrelations with torque and alignment changes were observed. There is a possibility that insertion torque was related to early-stage stability, but no statistical relation could be determined. (author)

  18. Twin Screw Mixer/Fine Grind Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The 40-mm Twin-Screw Mixer/Extruder (TSE) pilot plant is a continuous, remotely operated, flexible facility that can significantly enhance safety and environmental...

  19. Biomechanical evaluation of a second generation headless compression screw for ankle arthrodesis in a cadaver model.

    Science.gov (United States)

    Somberg, Andrew Max; Whiteside, William K; Nilssen, Erik; Murawski, Daniel; Liu, Wei

    2016-03-01

    Many types of screws, plates, and strut grafts have been utilized for ankle arthrodesis. Biomechanical testing has shown that these constructs can have variable stiffness. More recently, headless compression screws have emerged as an evolving method of achieving compression in various applications but there is limited literature regarding ankle arthrodesis. The aim of this study was to determine the biomechanical stability provided by a second generation fully threaded headless compression screw compared to a standard headed, partially threaded cancellous screw in a cadaveric ankle arthrodesis model. Twenty fresh frozen human cadaver specimens were subjected to simulated ankle arthrodesis with either three standard cancellous-bone screws (InFix 7.3mm) or with three headless compression screws (Acumed Acutrak 2 7.5mm). The specimens were subjected to cyclic loading and unloading at a rate of 1Hz, compression of 525 Newtons (N) and distraction of 20N for a total of 500 cycles using an electromechanical load frame (Instron). The amount of maximum distraction was recorded as well as the amount of motion that occurred through 1, 10, 50, 100, and 500 cycles. No significant difference (p=0.412) was seen in the amount of distraction that occurred across the fusion site for either screw. The average maximum distraction after 500 cycles was 201.9μm for the Acutrak 2 screw and 235.4μm for the InFix screw. No difference was seen throughout each cycle over time for the Acutrak 2 screw (p-value=0.988) or the InFix screw (p-value=0.991). Both the traditional InFix type screw and the second generation Acumed Acutrak headless compression screws provide adequate fixation during ankle arthrodesis under submaximal loads. There is no demonstrable difference between traditional cannulated partially threaded screws and headless compression screws studied in this model. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  20. Pedicle Screw Insertion Accuracy Using O-Arm, Robotic Guidance, or Freehand Technique: A Comparative Study.

    Science.gov (United States)

    Laudato, Pietro Aniello; Pierzchala, Katarzyna; Schizas, Constantin

    2018-03-15

    A retrospective radiological study. The aim of this study was to evaluate the accuracy of pedicle screw insertion using O-Arm navigation, robotic assistance, or a freehand fluoroscopic technique. Pedicle screw insertion using either "O-Arm" navigation or robotic devices is gaining popularity. Although several studies are available evaluating each of those techniques separately, no direct comparison has been attempted. Eighty-four patients undergoing implantation of 569 lumbar and thoracic screws were divided into three groups. Eleven patients (64 screws) had screws inserted using robotic assistance, 25 patients (191 screws) using the O-arm, while 48 patients (314 screws) had screws inserted using lateral fluoroscopy in a freehand technique. A single experienced spine surgeon assisted by a spinal fellow performed all procedures. Screw placement accuracy was assessed by two independent observers on postoperative computed tomography (CTs) according to the A to D Rampersaud criteria. No statistically significant difference was noted between the three groups. About 70.4% of screws in the freehand group, 69.6% in the O arm group, and 78.8% in the robotic group were placed completely within the pedicle margins (grade A) (P > 0.05). About 6.4% of screws were considered misplaced (grades C&D) in the freehand group, 4.2% in the O-arm group, and 4.7% in the robotic group (P > 0.05). The spinal fellow inserted screws with the same accuracy as the senior surgeon (P > 0.05). The advent of new technologies does not appear to alter accuracy of screw placement in our setting. Under supervision, spinal fellows might perform equally well to experienced surgeons using new tools. The lack of difference in accuracy does not imply that the above-mentioned techniques have no added advantages. Other issues, such as surgeon/patient radiation, fiddle factor, teaching suitability, etc., outside the scope of our present study, need further assessment. 3.

  1. A technique for the management of screw access opening in cement-retained implant restorations

    Directory of Open Access Journals (Sweden)

    Hamid Kermanshah

    2014-01-01

    Full Text Available Introduction: Abutment screw loosening has been considered as a common complication of implant-supported dental prostheses. This problem is more important in cement-retained implant restorations due to their invisible position of the screw access opening. Case Report: This report describes a modified retrievability method for cement-retained implant restorations in the event of abutment screw loosening. The screw access opening was marked with ceramic stain and its porcelain surface was treated using hydrofluoric acid (HF, silane, and adhesive to bond to composite resin. Discussion: The present modified technique facilitates screw access opening and improves the bond between the porcelain and composite resin.

  2. Novel free-hand T1 pedicle screw method: Review of 44 consecutive cases

    Directory of Open Access Journals (Sweden)

    Mark A Rivkin

    2014-01-01

    Full Text Available Summary of Background Data: Multilevel posterior cervical instrumented fusions are becoming more prevalent in current practice. Biomechanical characteristics of the cervicothoracic junction may necessitate extending the construct to upper thoracic segments. However, fixation in upper thoracic spine can be technically demanding owing to transitional anatomy while suboptimal placement facilitates vascular and neurologic complications. Thoracic instrumentation methods include free-hand, fluoroscopic guidance, and CT-based image guidance. However, fluoroscopy of upper thoracic spine is challenging secondary to vertebral geometry and patient positioning, while image-guided systems present substantial financial commitment and are not readily available at most centers. Additionally, imaging modalities increase radiation exposure to the patient and surgeon while potentially lengthening surgical time. Materials and Methods: Retrospective review of 44 consecutive patients undergoing a cervicothoracic fusion by a single surgeon using the novel free-hand T1 pedicle screw technique between June 2009 and November 2012. A starting point medial and cephalad to classic entry as well as new trajectory were utilized. No imaging modalities were employed during screw insertion. Postoperative CT scans were obtained on day 1. Screw accuracy was independently evaluated according to the Heary classification. Results: In total, 87 pedicle screws placed were at T1. Grade 1 placement occurred in 72 (82.8% screws, Grade 2 in 4 (4.6% screws and Grade 3 in 9 (10.3% screws. All Grade 2 and 3 breaches were <2 mm except one Grade 3 screw breaching 2-4 mm laterally. Only two screws (2.3% were noted to be Grade 4, both breaching medially by less than 2 mm. No new neurological deficits or returns to operating room took place postoperatively. Conclusions: This modification of the traditional starting point and trajectory at T1 is safe and effective. It attenuates additional bone

  3. [Clinical application of atlas translaminar screws fixation in treatment of atlatoaxial instability].

    Science.gov (United States)

    Wang, Guoyou; Fu, Shijie; Shen, Huarui; Guan, Taiyuan; Xu, Ping

    2013-10-01

    To explore the effectiveness of fixation of atlas translaminar screws in the treatment of atlatoaxial instability. A retrospective analysis was made on the clinical data of 32 patients with atlatoaxial instability treated with atlantoaxial trans-pedicle screws between March 2007 and August 2009. Of them, 7 patients underwent atlas translaminar screws combined with axis transpedicle screws fixation because of fracture types, anatomic variation, and intraoperative reason, including 5 males and 2 females with an average age of 48.2 years (range, 35-69 years). A total of 9 translaminar screws were inserted. Injury was caused by traffic accident in 4 cases, falling from height in 2 cases, and crushing in 1 case. Two cases had simple odontoid fracture (Anderson type II), and 5 cases had odontoid fracture combined with other injuries (massa lateralis atlantis fracture in 2, atlantoaxial dislocation in 1, and Hangman fracture in 2). The interval between injury and operation was 4-9 days (mean, 6 days). The preoperative Japanese Orthopaedic Association (JOA) score was 8.29 +/- 1.60. The X-ray films showed good position of the screws. Healing of incision by first intention was obtained, and no patient had injuries of the spinal cord injury, nerve root, and vertebral artery. Seven cases were followed up 9-26 months (mean, 14 months). Good bone fusion was observed at 8 months on average (range, 6-11 months). No loosening, displacement, and breakage of internal fixation, re-dislocation and instability of atlantoaxial joint, or penetrating of pedicle screw into the spinal canal and the spinal cord occurred. The JOA score was significantly improved to 15.29 +/- 1.38 at 6 months after operation (t = 32.078, P = 0.000). Atlas translaminar screws fixation has the advantages of firm fixation, simple operating techniques, and relative safety, so it may be a remedial measure of atlatoaxial instability.

  4. Clinical accuracy of three-dimensional fluoroscopy (IsoC-3D)-assisted upper thoracic pedicle screw insertion

    International Nuclear Information System (INIS)

    Sugimoto, Yoshihisa; Ito, Yasuo; Shimokawa, Tetsuya; Shiozaki, Yasuyuki; Mazaki, Tetsuro; Tomioka, Masao; Tanaka, Masato

    2010-01-01

    Correct screw placement is especially difficult in the upper thoracic vertebrae. At the cervicothoracic junction (C7-T2), problems can arise because of the narrowness of the pedicle and the difficulty of using a lateral image intensifier there. Other upper thoracic vertebrae (T3-6) pose a problem for screw insertion also because of the narrower pedicle. We inserted 154 pedicle screws into 78 vertebrae (C7 to T6) in 38 patients. Screws were placed using intraoperative data acquisition by an isocentric C-arm fluoroscope (Siremobile Iso-C3D) and computer navigation. Out of 90 pedicle screws inserted into 45 vertebrae between C7 and T2, 87 of the 90 (96.7%) screws were classified as grade 1 (no perforation). Of 64 pedicle screws inserted into 33 vertebrae between T3 and T6, 61 of 64 (95.3%) screws were classified as grade 1. In this study, we reduced pedicle screw misplacement at the level of the C7 and upper thoracic (T1-6) vertebrae using the three-dimensional fluoroscopy navigation system. (author)

  5. Pedicle Screw Fixation Study in Immature Porcine Spines to Improve Pullout Resistance during Animal Testing.

    Directory of Open Access Journals (Sweden)

    Sophie Le Cann

    Full Text Available The porcine model is frequently used during development and validation of new spinal devices, because of its likeness to the human spine. These spinal devices are frequently composed of pedicle screws with a reputation for stable fixation but which can suffer pullouts during preclinical implantation on young animals, leading to high morbidity. With a view to identifying the best choices to optimize pedicle screw fixation in the porcine model, this study evaluates ex vivo the impact of weight (age of the animal, the level of the vertebrae (lumbar or thoracic and the type of screw anchorage (mono- or bi-cortical on pedicle screw pullouts. Among the 80 pig vertebrae (90- and 140-day-old tested in this study, the average screw pullout forces ranged between 419.9N and 1341.2N. In addition, statistical differences were found between test groups, pointing out the influence of the three parameters stated above. We found that the the more caudally the screws are positioned (lumbar level, the greater their pullout resistance is, moreover, screw stability increases with the age, and finally, the screws implanted with a mono-cortical anchorage sustained lower pullout forces than those implanted with a bi-cortical anchorage. We conclude that the best anchorage can be obtained with older animals, using a lumbar fixation and long screws traversing the vertebra and inducing bi-cortical anchorage. In very young animals, pedicle screw fixations need to be bi-cortical and more numerous to prevent pullout.

  6. Pedicle Screw Fixation Study in Immature Porcine Spines to Improve Pullout Resistance during Animal Testing.

    Science.gov (United States)

    Le Cann, Sophie; Cachon, Thibaut; Viguier, Eric; Miladi, Lotfi; Odent, Thierry; Rossi, Jean-Marie; Chabrand, Patrick

    2015-01-01

    The porcine model is frequently used during development and validation of new spinal devices, because of its likeness to the human spine. These spinal devices are frequently composed of pedicle screws with a reputation for stable fixation but which can suffer pullouts during preclinical implantation on young animals, leading to high morbidity. With a view to identifying the best choices to optimize pedicle screw fixation in the porcine model, this study evaluates ex vivo the impact of weight (age) of the animal, the level of the vertebrae (lumbar or thoracic) and the type of screw anchorage (mono- or bi-cortical) on pedicle screw pullouts. Among the 80 pig vertebrae (90- and 140-day-old) tested in this study, the average screw pullout forces ranged between 419.9N and 1341.2N. In addition, statistical differences were found between test groups, pointing out the influence of the three parameters stated above. We found that the the more caudally the screws are positioned (lumbar level), the greater their pullout resistance is, moreover, screw stability increases with the age, and finally, the screws implanted with a mono-cortical anchorage sustained lower pullout forces than those implanted with a bi-cortical anchorage. We conclude that the best anchorage can be obtained with older animals, using a lumbar fixation and long screws traversing the vertebra and inducing bi-cortical anchorage. In very young animals, pedicle screw fixations need to be bi-cortical and more numerous to prevent pullout.

  7. An electromagnetic screw and nut system for operating vertical motions along an axis

    International Nuclear Information System (INIS)

    Fehr, Henri.

    1975-01-01

    This invention concerns a magnetic screw and nut system for operating control rods, designed for vertical mounting and having no mobile or slide contacts. It makes it possible to rotate a screw located inside a sealed tubular containment that can have a very thick wall. All the electromagnetic components entering into the operation are outside this containment. The magnetic screw has a constant air gap. The tube, manufactured of a non-magnetic material, includes two added annular pole pieces forming part of its wall and whose internal surfaces have a thread corresponding to that of the screw. The two annular pole pieces are spaced axially from each other by an amount equal to an integral number of thread pitches. An external winding and magnetic armature associated to these pole pieces form the fixed magnetic nut. A multiphase non-synchronous motor is placed around the tube and near the nut, the stator is external, the rotor is the screw. An appliance for fixing the degree of axial displacement freedom of the screw can be provided [fr

  8. Influence of abutment screw preload on stress distribution in marginal bone.

    Science.gov (United States)

    Khraisat, Ameen

    2012-01-01

    Changes in an implant assembly after abutment connection might possibly cause deformation in the implant/abutment joint and even in the marginal bone. The aim of this study was to evaluate the influence of abutment screw preload through the implant collar on marginal bone stress without external load application. Models of three implant parts made of titanium (implant, abutment, and abutment screw) and cortical bone were built and positioned with computer-aided design software. Meshing and generation of boundary conditions, loads, and interactions were performed. Each part was meshed independently. The sole load applied to the model was a torque of 32 Ncm on the abutment screw about its axis of rotation. The implant collar was deformed axially after the screw was tightened (3 μm). This deformation resulted in 60 MPa of stress in the marginal bone. Moreover, pressure on the marginal bone in a radial direction was observed. It can be concluded that, without any external load application, abutment screw preload exerts stresses on the implant collar and the marginal bone. These findings should help guide the development of new implant/abutment joint designs that exert less stress on the marginal bone.

  9. Performance Characteristics of a 4 × 6 Oil-Free Twin-Screw Compressor

    Directory of Open Access Journals (Sweden)

    Sun-Seok Byeon

    2017-07-01

    Full Text Available The screw compressor in the early stage of development is generally known as the oil-injection type. However, escalating environmental problems and advances in electronic components have spurred continuous R & D to minimize the oil content in compressed air. The oil-free twin-screw compressor is continuously compressed by inner volumetric change between rotors and casing. For this reason, in order to predict the overall performance of the screw compressor at the early stage of the design process, industry still relies on the empirical method. However, it is difficult using the existing empirical method to gain more information of the inner fluid flow of the twin-screw compressor. Flow simulation techniques using CFD are required. This study presents applications of a recently proposed overset grid method to the solution of the flow around a moving boundary. In order to analyze the performance of a 4 × 6 oil-free screw compressor, the 3-D, unsteady and compressible flow fields were numerically calculated with a shear stress transport (SST turbulence model, and implemented by the commercial software, Star-CCM+. The pressure distributions were calculated and graphically depicted. Results also showed that the volumetric and adiabatic efficiencies of the screw compressor measured by the experiments were 78% and 71%, respectively.

  10. Bioresorbable composite screws manufactured via forging process: pull-out, shear, flexural and degradation characteristics.

    Science.gov (United States)

    Felfel, R M; Ahmed, I; Parsons, A J; Rudd, C D

    2013-02-01

    Bioresorbable screws have the potential to overcome some of the complications associated with metallic screws currently in use. Removal of metallic screws after bone has healed is a serious issue which can lead to refracture due to the presence of screw holes. Poly lactic acid (PLA), fully 40 mol% P(2)O(5) containing phosphate unidirectional (P40UD) and a mixture of UD and short chopped strand random fibre mats (P40 70%UD/30%RM) composite screws were prepared via forging composite bars. Water uptake and mass loss for the composite screws manufactured increased significantly to ∼1.25% (P=0.0002) and ∼1.1% (P<0.0001), respectively, after 42 days of immersion in PBS at 37 °C. The initial maximum flexural load for P40 UD/RM and P40 UD composite screws was ∼60% (P=0.0047) and ∼100% (P=0.0037) higher than for the PLA screws (∼190 N), whilst the shear load was slightly higher in comparison to PLA (∼2.2 kN). The initial pull-out strengths for the P40 UD/RM and PLA screws were similar whereas that for P40 UD screws was ∼75% higher (P=0.022). Mechanical properties for the composite screws decreased initially after 3 days of immersion and this reduction was ascribed to the degradation of the fibre/matrix interface. After 3 days interval the mechanical properties (flexural, shear and pull-out) maintained their integrity for the duration of the study (at 42 days). This property retention was attributed to the chemical durability of the fibres used and stability of the matrix properties during the degradation process. It was also deemed necessary to enhance the fibre/matrix interface via use of a coupling agent in order to maintain the initial mechanical properties acquired for the required period of time. Lastly, it is also suggested that the degrading reinforcement fibres may have the potential to buffer any acidic products released from the PLA matrix. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Numerical simulation of a twin screw expander for performance prediction

    Science.gov (United States)

    Papes, Iva; Degroote, Joris; Vierendeels, Jan

    2015-08-01

    With the increasing use of twin screw expanders in waste heat recovery applications, the performance prediction of these machines plays an important role. This paper presents a mathematical model for calculating the performance of a twin screw expander. From the mass and energy conservation laws, differential equations are derived which are then solved together with the appropriate Equation of State in the instantaneous control volumes. Different flow processes that occur inside the screw expander such as filling (accompanied by a substantial pressure loss) and leakage flows through the clearances are accounted for in the model. The mathematical model employs all geometrical parameters such as chamber volume, suction and leakage areas. With R245fa as working fluid, the Aungier Redlich-Kwong Equation of State has been used in order to include real gas effects. To calculate the mass flow rates through the leakage paths formed inside the screw expander, flow coefficients are considered as constant and they are derived from 3D Computational Fluid Dynamic calculations at given working conditions and applied to all other working conditions. The outcome of the mathematical model is the P-V indicator diagram which is compared to CFD results of the same twin screw expander. Since CFD calculations require significant computational time, developed mathematical model can be used for the faster performance prediction.

  12. New concept single screw compressors and their manufacture technology

    Science.gov (United States)

    Feng, Q.; Liu, F.; Chang, L.; Feng, C.; Peng, C.; Xie, J.; van den Broek, M.

    2017-08-01

    Single screw compressors were generally acknowledged as one of the nearly perfect machines by compressor researchers and manufacturers. However the rapid wear of the star-wheel in a single screw compressor during operation is a key reason why it hasn’t previously joined the main current compressors’ market. After more than ten years of effective work, the authors of this paper have proposed a new concept single screw compressor whose mesh-couple profile is enveloped with multi-column. Also a new design method and manufacture equipment for this kind of compressor have been developed and are described in this paper. A lot of prototype tests and a long period of industrial operations under full loading conditions have shown that the mesh-couple profiles of the new concept single compressors have excellent anti-wearness.

  13. Screw engine used as an expander in ORC for low-potential heat utilization

    Science.gov (United States)

    Richter, Lukáš

    2017-09-01

    This paper deals with a screw motor that is used as an expander in an ORC (Organic Rankin Cycle) system, whose organic working substance allows the transformation of low-potential heat (waste heat, solar and geothermal energy) into electrical energy. The article describes the specific properties of an organic substance and a screw motor that must be considered when designing and assembling a complete power unit. Screw machines are not commonly used as expansion devices, so it is necessary to perform an analysis that makes it possible to adapt the screw machine to the expansion process in terms of profiling and design.

  14. The Research of Screw Thread Parameter Measurement Based on Position Sensitive Detector and Laser

    International Nuclear Information System (INIS)

    Tong, Q B; Ding, Z L; Chen, J C; Ai, L L; Yuan, F

    2006-01-01

    A technique and system of measuring screw thread parameter based on the theory of laser measurement is presented in this paper, which can be carried out the automated measurement of screw thread parameter. An inspection instrument was designed and produced, which included exterior imaging system of optical path, transverse displacement measurement system, axial displacement measurement system, and a module to deal with, control and assess the data in the upper system. The inspection and estimate of the screw thread contour curve were completed by using position sensitive device (PSD) as photoelectric detector to measure the coordinate data of the screw thread contour curve in the transverse section, and using precise raster to measure the axial displacement of the precision worktable under the screw thread test criterion., computer can gives a measured result according to coordinate data of the screw thread obtained by PSD. The relation between measured spot and image is established, and optimum design of the system organization are introduced, including the image length of receiving lens focal length optical system and the choice of PSD , and some main factor affected measuring precision are analyzed. The experimental results show that the measurement uncertainty of screw thread minor diameter can reach 0. 5μm, which can meet most requests for the measurement of screw thread parameter

  15. Microcontroller-based locking in optics experiments

    International Nuclear Information System (INIS)

    Huang, K.; Le Jeannic, H.; Ruaudel, J.; Morin, O.; Laurat, J.

    2014-01-01

    Optics experiments critically require the stable and accurate locking of relative phases between light beams or the stabilization of Fabry-Perot cavity lengths. Here, we present a simple and inexpensive technique based on a stand-alone microcontroller unit to perform such tasks. Easily programmed in C language, this reconfigurable digital locking system also enables automatic relocking and sequential functioning. Different algorithms are detailed and applied to fringe locking and to low- and high-finesse optical cavity stabilization, without the need of external modulations or error signals. This technique can readily replace a number of analog locking systems advantageously in a variety of optical experiments

  16. Microcontroller-based locking in optics experiments.

    Science.gov (United States)

    Huang, K; Le Jeannic, H; Ruaudel, J; Morin, O; Laurat, J

    2014-12-01

    Optics experiments critically require the stable and accurate locking of relative phases between light beams or the stabilization of Fabry-Perot cavity lengths. Here, we present a simple and inexpensive technique based on a stand-alone microcontroller unit to perform such tasks. Easily programmed in C language, this reconfigurable digital locking system also enables automatic relocking and sequential functioning. Different algorithms are detailed and applied to fringe locking and to low- and high-finesse optical cavity stabilization, without the need of external modulations or error signals. This technique can readily replace a number of analog locking systems advantageously in a variety of optical experiments.

  17. Microcontroller-based locking in optics experiments

    Energy Technology Data Exchange (ETDEWEB)

    Huang, K. [Laboratoire Kastler Brossel, UPMC-Sorbonne Universités, CNRS, ENS-PSL Research University, Collège de France, 4 place Jussieu, 75005 Paris (France); State Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai 200062 (China); Le Jeannic, H.; Ruaudel, J.; Morin, O.; Laurat, J., E-mail: julien.laurat@upmc.fr [Laboratoire Kastler Brossel, UPMC-Sorbonne Universités, CNRS, ENS-PSL Research University, Collège de France, 4 place Jussieu, 75005 Paris (France)

    2014-12-15

    Optics experiments critically require the stable and accurate locking of relative phases between light beams or the stabilization of Fabry-Perot cavity lengths. Here, we present a simple and inexpensive technique based on a stand-alone microcontroller unit to perform such tasks. Easily programmed in C language, this reconfigurable digital locking system also enables automatic relocking and sequential functioning. Different algorithms are detailed and applied to fringe locking and to low- and high-finesse optical cavity stabilization, without the need of external modulations or error signals. This technique can readily replace a number of analog locking systems advantageously in a variety of optical experiments.

  18. Radial and Regge excitations in unified, grand unified and subconstituent models

    International Nuclear Information System (INIS)

    Schnitzer, H.J.

    1981-01-01

    Necessary group theoretic conditions for all elementary gauge bosons and fermions of an arbitrary renormalizable gauge theory to lie on Regge trajectories are reviewed. It is then argued that in properly unified gauge theories all particles of a given spin lie on Regge trajectories. This then implies that a properly unified gauge theory has no local U(1) factor groups, and no massive fermion singlets. A consideration of the general pattern of Regge and radial recurrences to be expected in quantum field theories suggests that the presence or absence of spin 3/2 quarks and/or leptons in the TeV region will provide crucial clues to enable one to distinguish between various classes of unified, grand unified, and subconstituent models. The correct interpretation of such excited fermions will require correlation with the higgs boson mass and possible radial and Regge excitations of the weak vector bosons. (orig.)

  19. Parametric analysis and design of a screw extruder for slightly non-Newtonian (pseudoplastic materials

    Directory of Open Access Journals (Sweden)

    J.I. Orisaleye

    2018-04-01

    Full Text Available Extruders have found application in the food, polymer and pharmaceutical industries. Rheological characteristics of materials are important in the specification of design parameters of screw extruders. Biopolymers, which consist of proteins, nucleic acids and polysaccharides, are shear-thinning (pseudoplastic within normal operating ranges. However, analytical models to predict and design screw extruders for non-Newtonian pseudoplastic materials are rare. In this study, an analytical model suitable to design a screw extruder for slightly non-Newtonian materials was developed. The model was used to predict the performance of the screw extruder while processing materials with power law indices slightly deviating from unity (the Newtonian case. Using non-dimensional analysis, the effects of design and operational parameters were investigated. Expressions to determine the optimum channel depth and helix angle were also derived. The model is capable of predicting the performance of the screw extruder within the range of power law indices considered (1/2⩽n⩽1. The power law index influences the choice of optimum channel depth and helix angle of the screw extruder. Keywords: Screw extruder, Slightly non-Newtonian, Shear-thinning, Pseudoplastic, Biopolymer, Power law

  20. Dynamic modelling and PID loop control of an oil-injected screw compressor package

    Science.gov (United States)

    Poli, G. W.; Milligan, W. J.; McKenna, P.

    2017-08-01

    A significant amount of time is spent tuning the PID (Proportional, Integral and Derivative) control loops of a screw compressor package due to the unique characteristics of the system. Common mistakes incurred during the tuning of a PID control loop include improper PID algorithm selection and unsuitable tuning parameters of the system resulting in erratic and inefficient operation. This paper details the design and development of software that aims to dynamically model the operation of a single stage oil injected screw compressor package deployed in upstream oil and gas applications. The developed software will be used to assess and accurately tune PID control loops present on the screw compressor package employed in controlling the oil pressures, temperatures and gas pressures, in a bid to improve control of the operation of the screw compressor package. Other applications of the modelling software will include its use as an evaluation tool that can estimate compressor package performance during start up, shutdown and emergency shutdown processes. The paper first details the study into the fundamental operational characteristics of each of the components present on the API 619 screw compressor package and then discusses the creation of a dynamic screw compressor model within the MATLAB/Simulink software suite. The paper concludes by verifying and assessing the accuracy of the created compressor model using data collected from physical screw compressor packages.

  1. Factors influencing success of cement versus screw-retained implant restorations: a clinical review

    Directory of Open Access Journals (Sweden)

    Ahmad Manawar

    2012-10-01

    Full Text Available Aim: As more and more dental practitioners are focusing on implant-supported fixed restorations, some clinicians favor the use of cement retained restorations while others consider screw retained prosthesis to be the best choice. Discussion: In screw-retained restorations, the fastening screw provides a solid joint between the restoration and the implant abutment, while in cement-retained prostheses the restorative screw is eliminated to enhance esthetics, occlusal stability, and passive fit of the restorations. The factors that influence the type of fixation of the prostheses to the implants like passivity of the framework, ease of fabrication, occlusion, esthetics, accessibility, retention and retrievability are discussed in this article with scientific studies demonstrating superior outcomes of one technique over another. Screwretained implant restorations have an advantage of predictable retention, retrievability and lack of potentially retained subgingival cement. However, a few disadvantages exist such as precise placement of the implant for optimal and esthetic location of the screw access hole and obtaining passive fit. On the other hand, cement retained restorations eliminate unesthetic screw access holes, have passive fit of castings, reduced complexity of clinical and lab procedures, enhanced esthetics, reduced cost factors and non disrupted morphology of the occlusal table. Conclusion: This article compares the advantages, potential disadvantages and limitations of screw and cement retained restorations and their specific implications in the most common clinical situation.

  2. The Unified Theory of Physics

    OpenAIRE

    Chung, Ding-Yu

    2002-01-01

    The unified theory of physics unifies various phenomena in our observable universe and other universes. The unified theory is based on the zero-energy universe and the space-object structures. Different universes in different developmental stages are the different expressions of the space-object structures. The unified theory is divided into five parts: the space-object structures, cosmology, the periodic table of elementary particles, the galaxy formation, and the extreme force field. The sp...

  3. Heterogeneous Silicon III-V Mode-Locked Lasers

    Science.gov (United States)

    Davenport, Michael Loehrlein

    Mode-locked lasers are useful for a variety of applications, such as sensing, telecommunication, and surgical instruments. This work focuses on integrated-circuit mode-locked lasers: those that combine multiple optical and electronic functions and are manufactured together on a single chip. While this allows production at high volume and lower cost, the true potential of integration is to open applications for mode-locked laser diodes where solid state lasers cannot fit, either due to size and power consumption constraints, or where small optical or electrical paths are needed for high bandwidth. Unfortunately, most high power and highly stable mode-locked laser diode demonstrations in scientific literature are based on the Fabry-Perot resonator design, with cleaved mirrors, and are unsuitable for use in integrated circuits because of the difficulty of producing integrated Fabry-Perot cavities. We use silicon photonics and heterogeneous integration with III-V gain material to produce the most powerful and lowest noise fully integrated mode-locked laser diode in the 20 GHz frequency range. If low noise and high peak power are required, it is arguably the best performing fully integrated mode-locked laser ever demonstrated. We present the design methodology and experimental pathway to realize a fully integrated mode-locked laser diode. The construction of the device, beginning with the selection of an integration platform, and proceeding through the fabrication process to final optimization, is presented in detail. The dependence of mode-locked laser performance on a wide variety of design parameters is presented. Applications for integrated circuit mode-locked lasers are also discussed, as well as proposed methods for using integration to improve mode-locking performance to beyond the current state of the art.

  4. Metal Artifacts Reduction of Pedicle Screws on Spine Computed Tomography Images Using Variable Thresholding Technique

    International Nuclear Information System (INIS)

    Kaewlek, T.; Koolpiruck, D.; Thongvigitmanee, S.; Mongkolsuk, M.; Chiewvit, P.; Thammakittiphan, S.

    2012-01-01

    Metal artifacts are one of significant problems in computed tomography (CT). The streak lines and air gaps arise from metal implants of orthopedic patients, such as prosthesis, dental bucket, and pedicle screws that cause incorrect diagnosis and local treatment planning. A common technique to suppressed artifacts is by adjusting windows, but those artifacts still remain on the images. To improve the detail of spine CT images, the variable thresholding technique is proposed in this paper. Three medical cases of spine CT images categorized by the severity of artifacts (screws head, one full screw, and two full screws) were investigated. Metal regions were segmented by k-mean clustering, then transformed into a sinogram domain. The metal sinogram was identified by the variable thresholding method, and then replaced the new estimated values by linear interpolation. The modified sinogram was reconstructed by the filtered back- projection algorithm, and added the metal region back to the modified reconstructed image in order to reproduce the final image. The image quality of the proposed technique, the automatic thresholding (Kalender) technique, and window adjustment technique was compared in term of noise and signal to noise ratio (SNR). The propose method can reduce metal artifacts between pedicle screws. After processing by our proposed technique, noise in the modified images is reduced (screws head 121.15 to73.83, one full screw 160.88 to 94.04, and two full screws 199.73 to 110.05 from the initial image) and SNR is increased (screws head 0.87 to 1.88, one full screw 1.54 to 2.82, and two full screws 0.32 to 0.41 from the initial image). The variable thresholding technique can identify the suitable boundary for restoring the missing data. The efficiency of the metal artifacts reduction is indicated on the case of partial and full pedicle screws. Our technique can improve the detail of spine CT images better than automatic thresholding (Kalender) technique, and

  5. To retain or remove the syndesmotic screw: a review of literature

    NARCIS (Netherlands)

    T. Schepers (Tim)

    2011-01-01

    textabstractIntroduction: Syndesmotic positioning screws are frequently placed in unstable ankle fractures. Many facets of adequate placement techniques have been the subject of various studies. Whether or not the syndesmosis screw should be removed prior to weight-bearing is still debated. In this

  6. Atomistic simulations of cross-slip of jogged screw dislocations in copper

    DEFF Research Database (Denmark)

    Vegge, T.; Rasmussen, T.; Leffers, T.

    2001-01-01

    We have performed atomic-scare simulations of cross-slip processes of screw dislocations in copper, simulating jog-free dislocations as well as different types of jogged screw dislocations. Minimum-energy paths and corresponding transition state energies are obtained using the nudged-elastic...

  7. Surgical strategies to improve fixation in the osteoporotic spine: the effects of tapping, cement augmentation, and screw trajectory.

    Science.gov (United States)

    Kuhns, Craig A; Reiter, Michael; Pfeiffer, Ferris; Choma, Theodore J

    2014-02-01

    Study Design Biomechanical study of pedicle screw fixation in osteoporotic bone. Objective To investigate whether it is better to tap or not tap osteoporotic bone prior to placing a cement-augmented pedicle screw. Methods Initially, we evaluated load to failure of screws placed in cancellous bone blocks with or without prior tapping as well as after varying the depths of tapping prior to screw insertion. Then we evaluated load to failure of screws placed in bone block models with a straight-ahead screw trajectory as well as with screws having a 23-degree cephalad trajectory (toward the end plate). These techniques were tested with nonaugmented (NA) screws as well as with bioactive cement (BioC) augmentation prior to screw insertion. Results In the NA group, pretapping decreased fixation strength in a dose-dependent fashion. In the BioC group, the tapped screws had significantly greater loads to failure (p tapping prior to cement augmentation will substantially improve fixation when compared with not tapping. Angulating screws more cephalad also seems to enhance aging spine fixation.

  8. Performance Characteristics of a 4 × 6 Oil-Free Twin-Screw Compressor

    OpenAIRE

    Sun-Seok Byeon; Jae-Young Lee; Youn-Jea Kim

    2017-01-01

    The screw compressor in the early stage of development is generally known as the oil-injection type. However, escalating environmental problems and advances in electronic components have spurred continuous R & D to minimize the oil content in compressed air. The oil-free twin-screw compressor is continuously compressed by inner volumetric change between rotors and casing. For this reason, in order to predict the overall performance of the screw compressor at the early stage of the design ...

  9. A power recirculating test rig for ball screw endurance tests

    Directory of Open Access Journals (Sweden)

    Giberti Hermes

    2016-01-01

    Full Text Available A conceptual design of an innovative test rig for endurance tests of ball screws is presented in this paper. The test rig layout is based on the power recirculating principle and it also allows to overtake the main critical issues of the ball screw endurance tests. Among these there are the high power required to make the test, the lengthy duration of the same and the high loads between the screw and the frame that holds it. The article describes the test rig designed scheme, the kinematic expedients to be adopted in order to obtain the required performance and functionality and the sizing procedure to choose the actuation system.

  10. 30 CFR 56.12068 - Locking transformer enclosures.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Locking transformer enclosures. 56.12068 Section 56.12068 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... § 56.12068 Locking transformer enclosures. Transformer enclosures shall be kept locked against...

  11. Bilateral locked facets in the thoracic spine

    NARCIS (Netherlands)

    M.H.A. Willems; Braakman, R. (Reinder); B. van Linge (Bert)

    1984-01-01

    textabstractTwo cases of traumatic bilateral locked facets in the thoracic spine are reported. Both patients had only minor neurological signs. They both made a full neurological recovery after surgical reduction of the locked facets. Bilateral locked facets are very uncommon in the thoracic spine.

  12. Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates.

    Science.gov (United States)

    Burkhart, Klaus Josef; Mueller, Lars P; Krezdorn, David; Appelmann, Philipp; Prommersberger, Karl J; Sternstein, Werner; Rommens, Pol M

    2007-12-01

    Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs. Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0-mm radial head plate. Implants were tested under axial (N/mm) and torsional (Ncm/ degrees ) loads with a servohydraulic materials testing machine. The radial head plate was significantly stiffer than all other implants under axial as well as under torsional loads, with values of 36 N/mm and 13 Ncm/ degrees . The second-stiffest implant was the blade plate, with values of 20 N/mm and 6 Ncm/ degrees . The weakest implants were the 2.0-mm LCP, with values of 6 N/mm and 2 Ncm/ degrees , and the 2.0-mm crossed screws, with values of 18 N/mm and 2 Ncm/ degrees . The 2.4-mm T plate, with values of 14 N/mm and 4 Ncm/ degrees , and the 2.0-mm grid plate, with values of 8 N/mm and 4 Ncm/ degrees came to lie in the midfield. The 2.0-mm angle-stable plates-depending on their design-allow fixation with comparable or even higher stability than the bulky 2.4-mm nonlocking implants and 2.0-mm crossed screws.

  13. Computation of the lock-in ranges of phase-locked loops with PI filter

    OpenAIRE

    Aleksandrov, Konstantin D.; Kuznetsov, Nikolay; Leonov, Gennady A.; Neittaanmäki, Pekka; Yuldashev, Marat V.; Yuldashev, Renat V.

    2016-01-01

    In the present work the lock-in range of PLL-based circuits with proportionallyintegrating filter and sinusoidal phase-detector characteristics are studied. Considered circuits have sinusoidal phase detector characteristics. Analytical approach based on the methods of phase plane analysis is applied to estimate the lock-in ranges of the circuits under consideration. Obtained analytical results are compared with simulation results.

  14. The improvement of the edge screw connection in OSB and conventional particleboard

    Directory of Open Access Journals (Sweden)

    Popović Mlađan

    2006-01-01

    Full Text Available This work presents the method for improvement of direct screw connection performance in conventional particleboard (PB and oriented strand board (OSB. It is conceived on adhesive insertion into the pilot hole prior to embedment of the screw. The tests were carried out on the PB and OSB, both presenting interior boards and with the same nominal thickness of 18 mm. Particleboard screws of the 5 mm in diameter were inserted in the edge of the board. Pilot hole diameters were 2,5 mm and 3,0 mm and the depth of embedment was 30 mm for all tests. The chosen PVAc adhesive (type 3 with the addition of wood flour as consolidator in the range from 3-10% was inserted into pilot-hole. Tests were also obtained after consequent reassembly of the screw connection in order to examine the ratio of loss in withdrawal forces in such case. It was found that the insertion of PVAc adhesive into the pilot hole and the addition of wood flour have the positive effects on the screw withdrawal force in the tested boards.

  15. Design of three-dimensional visualization based on the posterior lumbar pedicle screw fixation

    Directory of Open Access Journals (Sweden)

    Kai XU

    2011-09-01

    Full Text Available Objective To establish a three-dimensional visualization model of posterior lumbar pedicle screw fixation.Methods A patient with lumbar intervertebral disc hernia and another patient with compression fracture of lumbar vertebra were involved in the present study.Both patients underwent multi-slice spiral CT scan before and after lumbar pedicle screw fixation.The degree of preoperative vertebral compression,vertebral morphology before and after surgery,postoperative pedicle screw position,and decompression effects were observed.The original data of the multi-slice spiral CT were inputted into the computer.The three-dimensional reconstructed images of the lumbar and implanted screws were obtained using the software Amira 4.1 to show the three-dimensional shape of the lumbar vertebrae before and after surgery and the location of the implanted screws.Results The morphology and structure of the lumbar vertebrae before and after surgery and of the implanted screws were reconstructed using the digital navigation platform.The reconstructed 3D images could be displayed in multicolor,transparent,or arbitrary combinations.In the 3D surface reconstruction images,the location and structure of the implanted screws could be clearly observed,and the decompression of the spinal cord or nerve roots and the severity of the fracture and the compression of lumbar vertebrae could be fully evaluated.The reconstructed images before operation revealed the position of the vertebral pedicles and provided reference for intraoperative localization.Conclusions The three-dimensional computerized reconstructions of lumbar pedicle screw fixation may be valuable in basic research,clinical experiment,and surgical planning.The software Amira is one of the bases of three-dimensional reconstruction.

  16. Bone anchors or interference screws? A biomechanical evaluation for autograft ankle stabilization.

    Science.gov (United States)

    Jeys, Lee; Korrosis, Sotiris; Stewart, Todd; Harris, Nicholas J

    2004-01-01

    Autograft stabilization uses free semitendinosus tendon grafts to anatomically reconstruct the anterior talofibular ligament. Study aims were to evaluate the biomechanical properties of Mitek GII anchors compared with the Arthrex Bio-Tenodesis Screw for free tendon reconstruction of the anterior talofibular ligament. There are no differences in load to failure and percentage specimen elongation at failure between the 2 methods. Controlled laboratory study using porcine models. Sixty porcine tendon constructs were failure tested. Re-creating the pull of the anterior talofibular ligament, loads were applied at 70 degrees to the bones. Thirty-six tendons were fixed to porcine tali and tested using a single pull to failure; 10 were secured with anchors and No. 2 Ethibond, 10 with anchors and FiberWire, 10 with screws and Fiberwire, and 6 with partially gripped screws. Cyclic preloading was conducted on 6 tendons fixed by anchors and on 6 tendons fixed by screws before failure testing. Two groups of 6 components fixed to the fibula were also tested. The talus single-pull anchor group produced a mean load of 114 N and elongation of 37% at failure. The talus single-pull screw group produced a mean load of 227 N and elongation of 22% at failure (P anchors. The improved biomechanics of interference screws suggests that these may be more suited to in vivo reconstruction of the anterior talofibular ligament than are bone anchors.

  17. To retain or remove the syndesmotic screw: a review of literature

    NARCIS (Netherlands)

    Schepers, T.

    2011-01-01

    Syndesmotic positioning screws are frequently placed in unstable ankle fractures. Many facets of adequate placement techniques have been the subject of various studies. Whether or not the syndesmosis screw should be removed prior to weight-bearing is still debated. In this study, the recent

  18. Intra-operative computer navigation guided cervical pedicle screw insertion in thirty-three complex cervical spine deformities

    Directory of Open Access Journals (Sweden)

    S Rajasekaran

    2010-01-01

    Full Text Available Background: Cervical pedicle screw fixation is challenging due to the small osseous morphometrics and the close proximity of neurovascular elements. Computer navigation has been reported to improve the accuracy of pedicle screw placement. There are very few studies assessing its efficacy in the presence of deformity. Also cervical pedicle screw insertion in children has not been described before. We evaluated the safety and accuracy of Iso-C 3D-navigated pedicle screws in the deformed cervical spine. Materials and Methods: Thirty-three patients including 15 children formed the study group. One hundred and forty-five cervical pedicle screws were inserted using Iso-C 3D-based computer navigation in patients undergoing cervical spine stabilization for craniovertebral junction anomalies, cervico-thoracic deformities and cervical instabilities due to trauma, post-surgery and degenerative disorders. The accuracy and containment of screw placement was assessed from postoperative computerized tomography scans. Results: One hundred and thirty (89.7% screws were well contained inside the pedicles. Nine (6.1% Type A and six (4.2% Type B pedicle breaches were observed. In 136 levels, the screws were inserted in the classical description of pedicle screw application and in nine deformed vertebra, the screws were inserted in a non-classical fashion, taking purchase of the best bone stock. None of them had a critical breach. No patient had any neurovascular complications. Conclusion: Iso-C navigation improves the safety and accuracy of pedicle screw insertion and is not only successful in achieving secure pedicle fixation but also in identifying the best available bone stock for three-column bone fixation in altered anatomy. The advantages conferred by cervical pedicle screws can be extended to the pediatric population also.

  19. A novel mode-locking technique

    International Nuclear Information System (INIS)

    Chen Shaoh; Chen Youming; Chen Taolue; Si Xiangdong; Yang Yi; Deng Ximing

    1993-01-01

    A novel mode-locked Nd:YAG oscillator has been developed by using an ultrafast photoconductive feedback controlled loop, and mode-locked pulses with a duration of 100ps have been obtained. The energy instability of the pulse trains is ±5%. In this type of mode-locking technology, a type of deep-level doped GaAs (Cr-doped) photoconductive switch, which has a fast response in time and is free of avalance process, is used to drive a Pockels' cell to realize mode-locking. The dark resistance of this type of photoconductive switch is 6 orders of magnitude higher than that of the intrinsic single-crystal silicon, and it can reach a level as high as 10 9 ohms. Consequently, it is able to withstand longterm operation at several thousand DC volts. By means of the photoconductive ohmic switch characteristics, the authors have designed a positive feedback control network which has a very fast response time, and can couple a voltage of up to a thousand volts. Using this unit in a Nd:YAG laser, they have successfully realized a very stable mode-locked pulse train with pulse width shorter than 100 ps. The operation principle, and the results of the preliminary experiments are presented here. 1 ref., 3 figs

  20. Ball tip method for thoracic pedicle screw placement in patients with adolescent idiopathic scoliosis

    International Nuclear Information System (INIS)

    Watanabe, Kota; Matsumoto, Morio; Iizuka, Shingo

    2008-01-01

    The purpose of this study was to evaluate the efficacy of ball tip method for thoracic pedicle screw placements in idiopathic scoliosis patients. 24 patients with adolescent idiopathic scoliosis were included in this study. Conventional method was performed in 12 patients. Ball tip method was performed in 12 patients. Accuracy of the pedicle screw placement was evaluated based on the postoperative CT. In the ball tip method, a probe which was consisted of ball tip with flexible shaft was used. After removing of cortical bone at a starting point, the probe was inserted manually or sometimes with gently tapping by hammer. During the maneuver, the probe will gradually progress into cancellous bone in the pedicle, without perforating cortical bone in the pedicle. Following expansion of the hole by a rigid gear shift probe, screw was placed in the pedicle. 65.1% of screws were located within pedicle in the conventional group and 86.5% in the ball tip group. 5.3% of screws were located out of pedicle within 2 mm in the conventional group and 8.2% in the ball tip group. 15.8% of screws were located out of pedicle beyond 2 mm and 1.8% in the ball tip group. The ball tip method enhanced the accuracy of thoracic pedicle screw placements in adolescent idiopathic scoliosis patients. The ball tip method may be effective for accurate pedicle screw placement in patients with adolescent idiopathic scoliosis. (author)

  1. Computed tomography fluoroscopy-guided placement of iliosacral screws in patients with unstable posterior pelvic fractures

    International Nuclear Information System (INIS)

    Iguchi, Toshihiro; Ogawa, Ken-Ichi; Doi, Takeshi; Munetomo, Kazuo; Miyasho, Koji; Hiraki, Takao; Kanazawa, Susumu; Ozaki, Toshifumi

    2010-01-01

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of the computed tomography (CT) fluoroscopy-guided placement of iliosacral screws in patients with unstable posterior pelvic fractures. Six patients (four women and two men; mean age 55.8 years; range 35-77 years) with unstable posterior pelvic fractures underwent iliosacral screw placement under CT fluoroscopy guidance between November 2007 and August 2008. Unstable pelvic ring injury (AO types B and C) was the indication for this procedure. In all the six patients except one, CT fluoroscopy-guided placement had been technically successful. In one patient, a second screw had been inserted, with a tilt to the caudal site, and slightly advanced into the extrasacral body; afterward, it could be exchanged safely for a shorter screw. Five patients and one patient underwent placement of two screws and one screw, respectively. The mean duration of the procedure was 15.0 min (range 9-30 min) per screw; the duration was 12.3 min and 18.2 min for the first and second screws, respectively. No complications requiring treatment occurred during or after the procedure. The mean clinical and radiologic follow-up period was 14 months (range 6-21 months). All pelvic injuries had healed satisfactorily, without complication, and all patients are now doing well clinically and can walk. CT fluoroscopy-guided placement of iliosacral screws is a safe and effective treatment in patients with unstable posterior pelvic fractures. (orig.)

  2. Virtual surgery simulation versus traditional approaches in training of residents in cervical pedicle screw placement.

    Science.gov (United States)

    Hou, Yang; Shi, Jiangang; Lin, Yanping; Chen, Huajiang; Yuan, Wen

    2018-06-01

    The cervical screw placement is one of the most difficult procedures in spine surgery, which often needs a long period of repeated practices and could cause screw placement-related complications. We performed this cadaver study to investigate the effectiveness of virtual surgical training system (VSTS) on cervical pedicle screw instrumentation for residents. A total of ten novice residents were randomly assigned to two groups: the simulation training (ST) group (n = 5) and control group (n = 5). The ST group received a surgical training of cervical pedicle screw placement on VSTS and the control group was given an introductory teaching session before cadaver test. Ten fresh adult spine specimens including 6 males and 4 females were collected, and were randomly allocated to the two groups. The bilateral C3-C6 pedicle screw instrumentation was performed in the specimens of the two groups, respectively. After instrumentation, screw positions of the two groups were evaluated by image examinations. There was significantly statistical difference in screw penetration rates between the ST (10%) and control group (62.5%, P VSTS as an advanced training tool exhibited promising effects on improving performance of novice residents in cervical pedicle screw placement compared with the traditional teaching methods.

  3. Power spectrum of an injection-locked Josephson oscillator

    International Nuclear Information System (INIS)

    Stancampiano, C.V.; Shapiro, S.

    1975-01-01

    Experiments have shown that a Josephson oscillator, exposed to a weak narrow-band input signal, exhibits behavior characteristic of an injection-locked oscillator. When in lock, Adler's theory of injection locking describes the experimental observations reasonably well. The range of applicability of the theory is extended to the out-of-lock regime where a spectrum of output frequencies is observed. Obtaining the theoretical output power spectrum requires solving a differential equation having the same form as the equation describing the resistively shunted junction model of Stewart and of McCumber. Experimental measurements of the output spectrum of a nearly locked Josephson oscillator are shown to be in reasonable agreement with the theory. Additional results discussed briefly include the observation of a frequency dependence of the locked Josephson oscillator output and experiments in which a Josephson oscillator-mixer was injection locked by a weak signal at the rf

  4. Experimental results of single screw mechanical tests: a follow-up to SAND2005-6036.

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sandwook; Lee, Kenneth L.; Korellis, John S.; McFadden, Sam X.

    2006-08-01

    The work reported here was conducted to address issues raised regarding mechanical testing of attachment screws described in SAND2005-6036, as well as to increase the understanding of screw behavior through additional testing. Efforts were made to evaluate fixture modifications and address issues of interest, including: fabrication of 45{sup o} test fixtures, measurement of the frictional load from the angled fixture guide, employment of electromechanical displacement transducers, development of a single-shear test, and study the affect of thread start orientation on single-shear behavior. A286 and 302HQ, No.10-32 socket-head cap screws were tested having orientations with respect to the primary loading axis of 0{sup 0}, 45{sup o}, 60{sup o}, 75{sup o} and 90{sup o} at stroke speeds 0,001 and 10 in/sec. The frictional load resulting from the angled screw fixture guide was insignificant. Load-displacement curves of A286 screws did not show a minimum value in displacement to failure (DTF) for 60{sup o} shear tests. Tests of 302HQ screws did not produce a consistent trend in DTF with load angle. The effect of displacement rate on DTF became larger as shear angle increased for both A286 and 302HQ screws.

  5. The variable finesse locking technique

    International Nuclear Information System (INIS)

    Acernese, F; Al-Shourbagy, M

    2006-01-01

    Virgo is a power recycled Michelson interferometer, with 3 km long Fabry-Perot cavities in the arms. The locking of the interferometer has been obtained with an original lock acquisition technique. The main idea is to lock the instrument away from its working point. Lock is obtained by misaligning the power recycling mirror and detuning the Michelson from the dark fringe. In this way, a good fraction of light escapes through the antisymmetric port and the power build-up inside the recycling cavity is extremely low. The benefit is that all the degrees of freedom are controlled when they are almost decoupled, and the linewidth of the recycling cavity is large. The interferometer is then adiabatically brought on to the dark fringe. This technique is referred to as variable finesse, since the recycling cavity is considered as a variable finesse Fabry-Perot. This technique has been widely tested and allows us to reach the dark fringe in few minutes, in an essentially deterministic way

  6. A resilient locking device for nuclear fuel bundles

    International Nuclear Information System (INIS)

    Curulla, M.V.; Smith, B.A.; Ashton, J.A.

    1974-01-01

    Description is given of a device wherein a spring and an abutment are maintained captive on a retaining screw. That device comprises a spring provided with at least one blade-shaped resilient portion and with an upper portion comprising an unthreaded hole, an abutment, a screw provided with a head, an intermediate stem portion and a threaded end-portion the diameter of which is higher than that of said intermediate stem portion, said spring and abutment being maintained trapped on said intermediate stem portion through the deformation of adjacent threads of said threaded end-protion of the screw and of the threaded hole of the abutment upper portion, in order to prevent said members from being separated [fr

  7. [Open double-row rotator cuff repair using the LASA-DR screw].

    Science.gov (United States)

    Schoch, C; Geyer, S; Geyer, M

    2016-02-01

    Safe and cost-effective rotator-cuff repair. All types of rotator cuff lesions. Frozen shoulder, rotator cuff mass defect, defect arthropathy. Extensive four-point fixation on the bony footprint is performed using the double-row lateral augmentation screw anchor (LASA-DR) with high biomechanical stability. Following mobilization of the tendons, these are refixed in the desired configuration first medially and then laterally. To this end, two drilling channels (footprint and lateral tubercle) are created for each screw. Using the shuttle technique, a suture anchor screw is reinforced with up to four pairs of threads. The medial row is then pierced and tied, and the sutures that have been left long are tied laterally around the screw heads (double row). 4 Weeks abduction pillow, resulting in passive physiotherapy, followed by initiation of active assisted physiotherapy. Full weight-bearing after 4-6 months. Prospective analysis of 35 consecutive Bateman-III lesions with excellent results and low rerupture rate (6%).

  8. EVALUATION OF FUNCTIONAL OUTCOME AFTER OPEN REDUCTION AND INTERNAL FIXATION OF DISTAL FEMUR FRACTURES BY LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    L. Lokanadha Rao

    2016-09-01

    Full Text Available BACKGROUND In the supra and intercondylar fractures of femur particularly with intra articular extension, patient may develop stiffness of knee, shortening, rotational deformities, internal derangement of knee with instability, varus and valgus deformities which affect patient’s routine lifestyle. If these cases were treated with locking compression plate, the results obtained were successful, superior, timesaving providing early ambulation and least disability improving the functional outcome. MATERIALS AND METHODS This is a prospective interventional study. This study includes 25 supracondylar and intercondylar fractures of femur (both Muller’s Type ‘A’, Type B and Type ‘C’ fractures treated with open reduction and internal fixation by Locking Compression Plate in the Department of Orthopaedics, King George Hospital, Visakhapatnam from September 2013 to September 2015. There are 16 males and 9 females with age ranging from 20 to 80 years with an average of 44.6 years. Average age for males is 28.9 years and average age for females is 25 years. 18 fractures were due to road traffic accidents and 6 cases are due to fall from significant heights, 1 case due to simple fall from standing (osteoporosis. 15 cases were in right femur (60% and 10 cases were in left femur (40%. RESULTS 25 cases were included in the study. There is an increase in the rate of union, decreased time taken for union, increased knee range of motion, decreased time for weight-bearing, postoperative complications and duration for hospital stay. CONCLUSION LCP proved to be a good implant which could take the challenges like poor bone stock, severe comminution both metaphyseal and articular and prove successful. The locking head screws distally have prevented varus collapse, even in cases of osteoporosis. The Condylar LCP can be used in either an open or a minimally invasive manner.

  9. Deformations of the spin currents by topological screw dislocation and cosmic dispiration

    International Nuclear Information System (INIS)

    Wang, Jianhua; Ma, Kai; Li, Kang; Fan, Huawei

    2015-01-01

    We study the spin currents induced by topological screw dislocation and cosmic dispiration. By using the extended Drude model, we find that the spin dependent forces are modified by the nontrivial geometry. For the topological screw dislocation, only the direction of spin current is bent by deforming the spin polarization vector. In contrast, the force induced by cosmic dispiration could affect both the direction and magnitude of the spin current. As a consequence, the spin-Hall conductivity does not receive corrections from screw dislocation.

  10. Deformations of the spin currents by topological screw dislocation and cosmic dispiration

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jianhua [School of Physics Science, Shaanxi University of Technology, Hanzhong 723000, Shaanxi (China); Ma, Kai, E-mail: makainca@gmail.com [School of Physics Science, Shaanxi University of Technology, Hanzhong 723000, Shaanxi (China); Li, Kang [Department of Physics, Hangzhou Normal University, Hangzhou 310036, Zhejiang (China); Fan, Huawei [School of Physics and Information Technology, Shaanxi Normal University, Xian 710000, Shaanxi (China)

    2015-11-15

    We study the spin currents induced by topological screw dislocation and cosmic dispiration. By using the extended Drude model, we find that the spin dependent forces are modified by the nontrivial geometry. For the topological screw dislocation, only the direction of spin current is bent by deforming the spin polarization vector. In contrast, the force induced by cosmic dispiration could affect both the direction and magnitude of the spin current. As a consequence, the spin-Hall conductivity does not receive corrections from screw dislocation.

  11. Parameters Affecting the Extraction Process of Jatropha curcas Oil Using a Single Screw Extruder

    Directory of Open Access Journals (Sweden)

    Ali Nurrakhmad Siregar

    2015-07-01

    Full Text Available The most commonly used technique to separate oil and cake from J. curcas seeds is mechanical extraction. It uses simple tools such as a piston and a screw extruder to produce high pressure, driven by hand or by engine. A single screw extruder has one screw rotating inside the barrel and materials simultaneously flow from the feed to the die zone. The highest oil yield can be obtained by a well-designed oil press as well as finding the optimum conditions for all parameters involved during the extraction process. The influence of the parameters in a single screw extruder was studied using finite element analysis and computational fluid dynamics simulation with ANSYS POLYFLOW. The research focused on predicting the velocity, pressure and shear rate in the metering section that influenced the screw rotational speed and mass flow rate. The obtained results revealed that increasing the screw rotational speed will increase the pressure, velocity and shear rate. Meanwhile, increasing the mass flow rate results in decreasing the pressure while the velocity and shear rate remain constant.

  12. Hersendood. Mackies leibniziaanse herinterpretatie van Lockes theorie van persoonsidentiteit

    OpenAIRE

    De Vleeschouwer, Gregory

    2009-01-01

    In his book, 'Problems from Locke', John Leslie Mackie presents a theory of personal identity (pi) that is meant to be a supplement and correction of Locke's pi-theory. In a first part I introduce the criterion of pi that was standard before Locke's pi-theory. By showing in a second part how Locke reacted against this traditional criterion, I show wherein the singularity of Locke's pi-theory exists. In a third part I explain how Leibniz is moved by the same solicitude as Locke, but also how h...

  13. Brain communication in the locked-in state.

    Science.gov (United States)

    De Massari, Daniele; Ruf, Carolin A; Furdea, Adrian; Matuz, Tamara; van der Heiden, Linda; Halder, Sebastian; Silvoni, Stefano; Birbaumer, Niels

    2013-06-01

    Patients in the completely locked-in state have no means of communication and they represent the target population for brain-computer interface research in the last 15 years. Although different paradigms have been tested and different physiological signals used, to date no sufficiently documented completely locked-in state patient was able to control a brain-computer interface over an extended time period. We introduce Pavlovian semantic conditioning to enable basic communication in completely locked-in state. This novel paradigm is based on semantic conditioning for online classification of neuroelectric or any other physiological signals to discriminate between covert (cognitive) 'yes' and 'no' responses. The paradigm comprised the presentation of affirmative and negative statements used as conditioned stimuli, while the unconditioned stimulus consisted of electrical stimulation of the skin paired with affirmative statements. Three patients with advanced amyotrophic lateral sclerosis participated over an extended time period, one of which was in a completely locked-in state, the other two in the locked-in state. The patients' level of vigilance was assessed through auditory oddball procedures to study the correlation between vigilance level and the classifier's performance. The average online classification accuracies of slow cortical components of electroencephalographic signals were around chance level for all the patients. The use of a non-linear classifier in the offline classification procedure resulted in a substantial improvement of the accuracy in one locked-in state patient achieving 70% correct classification. A reliable level of performance in the completely locked-in state patient was not achieved uniformly throughout the 37 sessions despite intact cognitive processing capacity, but in some sessions communication accuracies up to 70% were achieved. Paradigm modifications are proposed. Rapid drop of vigilance was detected suggesting attentional

  14. Locked modes and magnetic field errors in MST

    International Nuclear Information System (INIS)

    Almagri, A.F.; Assadi, S.; Prager, S.C.; Sarff, J.S.; Kerst, D.W.

    1992-06-01

    In the MST reversed field pinch magnetic oscillations become stationary (locked) in the lab frame as a result of a process involving interactions between the modes, sawteeth, and field errors. Several helical modes become phase locked to each other to form a rotating localized disturbance, the disturbance locks to an impulsive field error generated at a sawtooth crash, the error fields grow monotonically after locking (perhaps due to an unstable interaction between the modes and field error), and over the tens of milliseconds of growth confinement degrades and the discharge eventually terminates. Field error control has been partially successful in eliminating locking

  15. Influence of bacterial colonization of the healing screws on peri-implant tissue

    Directory of Open Access Journals (Sweden)

    Simonetta D'Ercole

    2013-06-01

    Conclusion: The healing screws left in situ for a period of 90 days caused a peri-implant inflammation and the presence of periodontal pathogenic bacteria in the peri-implant sulcus, due to the plaque accumulation on screw surfaces.

  16. THE DESIGN, FABRICATION AND PRELIMINARY TESTING OF AN INDIGENOUS SINGLE SCREW EXTRUDER

    Directory of Open Access Journals (Sweden)

    FOLASAYO T. FAYOSE

    2017-10-01

    Full Text Available Developing countries including Nigeria have become dumping grounds of unserviceable and broken down imported machineries because of poor adaptation. Detailed study and design of machines to suit local conditions will prevent poor adaptation of imported machines and high initial costs. In this study, a single screw starch extruder was designed, fabricated and tested using locally available materials. The extruder is the dry type and it has 27.12 kg/s capacity, a compression ratio of 4.5: 1 and is powered by a 5.5 kW electric motor. It consists of a hopper, feeding screw, extruder screw rotating in a barrel and variable die, all made of stainless steel. A unit of the machine costs N 470, 390.00.00 as at April 2015. When used to process cassava flour, a maximum temperature of 114°C was attained through viscous dissipation, up to an actual screw speed of 98.96 rpm (1.65 Hz and extruder efficiency of 64%. Barrel temperature varied directly with extrusion time in a polynomial trend while actual extruder screw speed and efficiency varied inversely with extrusion time and it is best fitted with a polynomial trend.

  17. Using three-dimensional rapid prototyping in the design and development of orthopaedic screws in standardised pull-out tests.

    Science.gov (United States)

    Leslie, Laura Jane; Connolly, Ashley; Swadener, John G; Junaid, Sarah; Theivendran, Kanthan; Deshmukh, Subodh C

    2018-05-01

    The majority of orthopaedic screws are designed, tested and manufactured by existing orthopaedics companies and are predominantly developed with healthy bone in mind. The timescales and costs involved in the development of a new screw design, for example, for osteoporotic bone, are high. In this study, standard wood screws were used to analyse the concept of using three-dimensional printing, or rapid prototyping, as a viable stage of development in the design of a new bone screw. Six wood screws were reverse engineered and printed in polymeric material using stereolithography. Three of the designs were also printed in Ti6Al4V using direct metal laser sintering; however, these were not of sufficient quality to test further. Both the original metal screws (metal) and polymeric rapid prototyping screws were then tested using standard pull-out tests from low-density polyurethane blocks (Sawbones). Results showed the highest pull-out strengths for screws with the longest thread length and the smallest inner diameter. Of the six screw designs tested, five showed no more than a 17% variance between the metal and rapid prototyping results. A similar pattern of results was shown between the screw designs for both the metal and rapid prototyping screws in five of the six cases. While not producing fully comparable pull-out results to orthopaedic screws, the results from this study do provide evidence of the potential usefulness and cost-effectiveness of rapid prototyping in the early stages of design and testing of orthopaedic screws.

  18. Shareholder Lock-In Contracts : Share Price and Trading Volume Effects at the Lock-In Expiry

    NARCIS (Netherlands)

    Angenandt, P.P.; Goergen, M.; Renneboog, L.D.R.

    2005-01-01

    This paper unveils the diversity in lock-in agreements of firms listed on the Nouveau Marche stock exchange in France.We give the main economic reasons why shareholders adopt lock-in agreements that are more stringent than legally required.We relate the abnormal returns and the abnormal volume at

  19. 49 CFR Appendix A to Part 238 - Schedule of Civil Penalties 1

    Science.gov (United States)

    2010-10-01

    ...) Overheated 5,000 7,500 (ii) Cap screw loose or missing 2,500 5,000 (iii) Cap screw lock broken or missing 1,000 2,000 (iv) Seal loose, damaged, or leaks lubricant 2,500 5,000 (e)(17) Air compressor inoperative...

  20. Development of a high speed extrusion concept using a floating screw sleeve for solid-melt-separation

    Science.gov (United States)

    Karrenberg, Gregor; Wortberg, Johannes

    2015-05-01

    The High-Speed-S-Truder with floating screw sleeve is an alternative extrusion concept with solid-melt-separation. A fairly conventional 35 mm screw with a length of 21 D, which is accelerated by a 75 kW gearless, water cooled synchronous drive, conveys the resin into a 60 mm screw sleeve with a length of 10 D. Inside the sleeve the material is plasticizied and discharged into the outer screw channel of the sleeve through radial bores. Only the solid bed remains inside. The development of a melt pool - and thus a decrease of the plasticizing capacity - is avoided. The sleeve is rotated by drag forces only (approximately 10 - 15 % of the screw speed). Due to the low speed of the screw sleeve molten material is conveyed to a 4 D Dynamic Mixing Ring in a gentle manner. The DMRs floating ring and the screw sleeve are directly coupled. The granules in the screw channel are stopped by a barrier on the screw in front of the mixing device. So nearly no unmelted material can pass the system. For temperature management in the plastification and mixing zone a 3-zone heating/air-cooling system is used. Various kinds of experiments with the High-Speed S-Truder were conducted. Reachable throughputs with different types of material (LDPE, LLDPE, PP, PS) have been tested. Also three screw geometries, which are mainly varying in the channel depth, were compared. Experimental results and theoretical background will be described in this paper.

  1. Increase of operational reliability and durability of square sectoral working bodies of flexible screw conveyors

    Directory of Open Access Journals (Sweden)

    O.L. Lyashuk

    2017-12-01

    Full Text Available The construction of the device for guiding screw sectional working bodies of increased operational reliability and durability and the method of determination of the force of guiding the design parameters are given. Two main methods of manufacturing screw mechanisms of machines of various service purposes were investigated and it was established that twisted screws, in terms of their strength and performance, considerably exceed rolling stock. The design of the device for manufacturing screw working bodies of conveyors by means of cutting by periodic and continuous methods, as the most reliable in operation, is developed. The specifics of their work are due to various operations of technological processes, as well as physical and mechanical properties of goods, determine the nomenclature and design parameters of screw mechanisms (SM. In studying the processes of forming screw spirals, the basic precision characteristics of the methods of drilling and rolling are established. A comparative study of two main methods in terms of their operational and durable capabilities has been carried out. An important factor determining the reliability and durability of a screw is the difference in the thickness of the inner and outer edges.

  2. Investigation of a Ball Screw Feed Drive System Based on Dynamic Modeling for Motion Control

    Directory of Open Access Journals (Sweden)

    Yi-Cheng Huang

    2017-06-01

    Full Text Available This paper examines the frequency response relationship between the ball screw nut preload, ball screw torsional stiffness variations and table mass effect for a single-axis feed drive system. Identification for the frequency response of an industrial ball screw drive system is very important for the precision motion when the vibration modes of the system are critical for controller design. In this study, there is translation and rotation modes of a ball screw feed drive system when positioning table is actuated by a servo motor. A lumped dynamic model to study the ball nut preload variation and torsional stiffness of the ball screw drive system is derived first. The mathematical modeling and numerical simulation provide the information of peak frequency response as the different levels of ball nut preload, ball screw torsional stiffness and table mass. The trend of increasing preload will indicate the abrupt peak change in frequency response spectrum analysis in some mode shapes. This study provides an approach to investigate the dynamic frequency response of a ball screw drive system, which provides significant information for better control performance when precise motion control is concerned.

  3. Non-symmetric approach to single-screw expander and compressor modeling

    Science.gov (United States)

    Ziviani, Davide; Groll, Eckhard A.; Braun, James E.; Horton, W. Travis; De Paepe, M.; van den Broek, M.

    2017-08-01

    Single-screw type volumetric machines are employed both as compressors in refrigeration systems and, more recently, as expanders in organic Rankine cycle (ORC) applications. The single-screw machine is characterized by having a central grooved rotor and two mating toothed starwheels that isolate the working chambers. One of the main features of such machine is related to the simultaneous occurrence of the compression or expansion processes on both sides of the main rotor which results in a more balanced loading on the main shaft bearings with respect to twin-screw machines. However, the meshing between starwheels and main rotor is a critical aspect as it heavily affects the volumetric performance of the machine. To allow flow interactions between the two sides of the rotor, a non-symmetric modelling approach has been established to obtain a more comprehensive model of the single-screw machine. The resulting mechanistic model includes in-chamber governing equations, leakage flow models, heat transfer mechanisms, viscous and mechanical losses. Forces and moments balances are used to estimate the loads on the main shaft bearings as well as on the starwheel bearings. An 11 kWe single-screw expander (SSE) adapted from an air compressor operating with R245fa as working fluid is used to validate the model. A total of 60 steady-steady points at four different rotational speeds have been collected to characterize the performance of the machine. The maximum electrical power output and overall isentropic efficiency measured were 7.31 kW and 51.91%, respectively.

  4. [Basic laws of blood screw motion in human common carotid arteries].

    Science.gov (United States)

    Kulikov, V P; Kirsanov, R I

    2008-08-01

    The basic laws of blood screw motion in common carotid arteries in people were determined by means of modern ultrasound techniques for the first time. 92 healthy adults, aged 18-30, were examined. The blood flow in the middle one-third of common carotid arteries was registered by means of Color Doppler Imaging and impulse Doppler with the help of ultrasound Medison 8000EX scanner by linear transducer of 5-9 MHz. The steady registration of blood screw motion in both common carotid arteries in Color Doppler Imaging regimen was observed in 54.3 % of cases. The direction of screw stream rotation in most cases (54%) was multi-directed: in the right common carotid artery it was right, in the left common carotid artery--left (48%), and in 6% of cases it was reverse. For 46% of cases blood rotation in both common carotid arteries was one-directed (26%--right, 20%--left). The velocity parameters of rotation component of blood motion were determined, maximum velocity being 19.68 +/- 5.84 cm/sec, minimum--4.57 +/- 2.89 cm/sec, average--7.48 +/- 2.49 cm/sec, angular--10.7 +/- 2.49 sec(-1). The rated velocity of blood cells motion in screw motion with regard of screw current lines to the vessel vertical axis makes up from 158.67 +/- 32.79 to 224.39 +/- 46.37 cm/sec.

  5. [Comparative study on the strength of different mechanisms of operation of multidirectionally angle-stable distal radius plates].

    Science.gov (United States)

    Rausch, S; Hoffmeier, K; Gueorguiev, B G; Klos, K; Gras, F; Hofmann, G O; Mückley, T

    2011-12-01

    Polyaxial angle-stable plating is thought to be particularly beneficial in the management of complex intra-articular fractures of the distal radius. The present study was performed to investigate the strength of polyaxial locking interfaces of distal radius plates. We tested the polyaxial interfaces of 3 different distal radius plates (2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate, Synthes, Palmar Classic, Königsee Implantate and VariAx Plate Stryker). The strength of 0° and 10° screw locking angle was obtained during static loading. The strength of Palmar Classic with a 0° locking angle is significantly the best of all tested systems. With a 10° locking angle there is no significant difference between Palmar Classic, Two column Plate and VariAx Plate. The strength of polyaxial interfaces differs between the tested systems. A reduction of ultimate strength is due to increases of screw locking angle. The design of polyaxial locking interfaces should be investigated in human bone models. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Comparison of 3D displacements of screw-retained zirconia implant crowns into implants with different internal connections with respect to screw tightening.

    Science.gov (United States)

    Rebeeah, Hanadi A; Yilmaz, Burak; Seidt, Jeremy D; McGlumphy, Edwin; Clelland, Nancy; Brantley, William

    2018-01-01

    Internal conical implant-abutment connections without horizontal platforms may lead to crown displacement during screw tightening and torque application. This displacement may affect the proximal contacts and occlusion of the definitive prosthesis. The purpose of this in vitro study was to evaluate the displacement of custom screw-retained zirconia single crowns into a recently introduced internal conical seal implant-abutment connection in 3D during hand and torque driver screw tightening. Stereolithic acrylic resin models were printed using computed tomography data from a patient missing the maxillary right central incisor. Two different internal connection implant systems (both ∼11.5 mm) were placed in the edentulous site in each model using a surgical guide. Five screw-retained single zirconia computer-aided design and computer-aided manufacturing (CAD-CAM) crowns were fabricated for each system. A pair of high-resolution digital cameras was used to record the relationship of the crown to the model. The crowns were tightened according to the manufacturers' specifications using a torque driver, and the cameras recorded their relative position again. Three-dimensional image correlation was used to measure and compare crown positions, first hand tightened and then torque driven. The displacement test was repeated 3 times for each crown. Commercial image correlation software was used to extract the data and compare the amount of displacement vertically, mesiodistally, and buccolingually. Repeated-measures ANOVA calculated the relative displacements for all 5 specimens for each implant for both crown screw hand tightening and after applied torque. A Student t test with Bonferroni correction was used for pairwise comparison of interest to determine statistical differences between the 2 implants (α=.05). The mean vertical displacements were statistically higher than the mean displacements in the mesiodistal and buccolingual directions for both implants

  7. Screw compressor analysis from a vibration point-of-view

    Science.gov (United States)

    Hübel, D.; Žitek, P.

    2017-09-01

    Vibrations are a very typical feature of all compressors and are given great attention in the industry. The reason for this interest is primarily the negative influence that it can have on both the operating staff and the entire machine's service life. The purpose of this work is to describe the methodology of screw compressor analysis from a vibration point-of-view. This analysis is an essential part of the design of vibro-diagnostics of screw compressors with regard to their service life.

  8. Research on the performance of water-injection twin screw compressor

    International Nuclear Information System (INIS)

    Li Jianfeng; Wu Huagen; Wang Bingming; Xing Ziwen; Shu Pengcheng

    2009-01-01

    Due to the development of the automotive fuel cell systems, the study on water-injection twin screw compressor has been aroused again. Twin screw compressors with water injection can be used to supply the clean compressed air for the Proton Exchange Membrane (PEM) fuel cell systems. In this research, a thermodynamic model of the working process of water-injection twin screw compressor was established based on the equations of conservation of mass and energy. The effects of internal leakage and air-water heat transfer were taken into account simultaneously in the present mathematical model. The experiments of the performance of a prototype compressor operating under various conditions were conducted to verify the model. The results show that the predictions of the model are in reasonable agreement with the experimental data.

  9. Internally Heated Screw Pyrolysis Reactor (IHSPR) heat transfer performance study

    Science.gov (United States)

    Teo, S. H.; Gan, H. L.; Alias, A.; Gan, L. M.

    2018-04-01

    1.5 billion end-of-life tyres (ELT) were discarded globally each year and pyrolysis is considered the best solution to convert the ELT into valuable high energy-density products. Among all pyrolysis technologies, screw reactor is favourable. However, conventional screw reactor risks plugging issue due to its lacklustre heat transfer performance. An internally heated screw pyrolysis reactor (IHSPR) was developed by local renewable energy industry, which serves as the research subject for heat transfer performance study of this particular paper. Zero-load heating test (ZLHT) was first carried out to obtain the operational parameters of the reactor, followed by the one dimensional steady-state heat transfer analysis carried out using SolidWorks Flow Simulation 2016. Experiments with feed rate manipulations and pyrolysis products analyses were conducted last to conclude the study.

  10. Biomechanical comparison of force levels in spinal instrumentation using monoaxial versus multi degree of freedom postloading pedicle screws.

    Science.gov (United States)

    Wang, Xiaoyu; Aubin, Carl-Eric; Crandall, Dennis; Labelle, Hubert

    2011-01-15

    biomechanical analysis and simulations of correction mechanisms and force levels during scoliosis instrumentation using two types of pedicle screws and primary correction maneuvers. to biomechanically analyze implant-vertebra and inter-vertebral forces during scoliosis correction, to address the hypothesis that multi degree of freedom (MDOF) postloading screws with a direct incremental segmental translation (DIST) correction technique significantly reduce the loads as compared with monoaxial (MA) tulip-top design screws with a rod derotation technique (RDT). MA screw is widely used for spinal instrumentation. The MDOF screw was introduced as a refinement of the correction philosophy based on multiaxial screws. The kinematics of the MDOF construct is fundamentally different and offers more degrees of freedom than that of the MA construct; however, a systematic comparison of their biomechanics has not been done so far. a biomechanical model was developed to simulate the instrumentation of six scoliotic patients, first with the MDOF screws and DIST. Then, the instrumentation with MA screws and RDT was simulated using the same cases. Thirty more simulations were done to study the force-level sensitivity to small implant placement variation. there was a small average difference of 7°, 5°, and 4° between the two simulated systems for the computed main thoracic Cobb angle, kyphosis, and apical axial rotation, respectively. On average, the mean, standard deviation (SD), and maximum values of the implant-vertebra forces for MDOF screws were 56%, 59%, and 59%, respectively, lower than those for the MA screws, while the intervertebral forces for the MDOF screws were 31%, 37%, and 36% lower, respectively. Under the same set of random small implant placement changes, the mean, SD, and maximum values of implant-vertebra force magnitude changes for MDOF screws were 93%, 92%, and 95%, respectively, lower than those for MA screws. with MDOF screws and DIST, it is possible for

  11. Scapula fracture incidence in reverse total shoulder arthroplasty using screws above or below metaglene central cage: clinical and biomechanical outcomes.

    Science.gov (United States)

    Kennon, Justin C; Lu, Caroline; McGee-Lawrence, Meghan E; Crosby, Lynn A

    2017-06-01

    Reverse total shoulder arthroplasty (RTSA) is a viable treatment option for rotator cuff tear arthropathy but carries a complication risk of scapular fracture. We hypothesized that using screws above the central glenoid axis for metaglene fixation creates a stress riser contributing to increased scapula fracture incidence. Clinical type III scapular fracture incidence was determined with screw placement correlation: superior screw vs. screws placed exclusively below the glenoid midpoint. Cadaveric RTSA biomechanical modeling was employed to analyze scapular fractures. We reviewed 318 single-surgeon single-implant RTSAs with screw correlation to identify type III scapular fractures. Seventeen cadaveric scapula specimens were matched for bone mineral density, metaglenes implanted, and fixation with 2 screw configurations: inferior screws alone (group 1 INF ) vs. inferior screws with one additional superior screw (group 2 SUP ). Biomechanical load to failure was analyzed. Of 206 patients, 9 (4.4%) from the superior screw group experienced scapula fractures (type III); 0 fractures (0/112; 0%) were identified in the inferior screw group. Biomechanically, superior screw constructs (group 2 SUP ) demonstrated significantly (P < .05) lower load to failure (1077 N vs. 1970 N) compared with constructs with no superior screws (group 1 INF ). There was no significant age or bone mineral density discrepancy. Clinical scapular fracture incidence significantly decreased (P < .05) for patients with no screws placed above the central cage compared with patients with superior metaglene screws. Biomechanical modeling demonstrates significant construct compromise when screws are used above the central cage, fracturing at nearly half the ultimate load of the inferior screw constructs. We recommend use of inferior screws, all positioned below the central glenoid axis, unless necessary to stabilize the metaglene construct. Copyright © 2016 Journal of Shoulder and Elbow Surgery

  12. Accuracy of navigated pedicle screw insertion by a junior spine surgeon without spinal surgery experience

    International Nuclear Information System (INIS)

    Yamazaki, Hironori; Kotani, Toshiaki; Motegi, Hiroyuki; Nemoto, Tetsuharu; Koshi, Takana; Nagahara, Ken; Minami, Syohei

    2010-01-01

    The purpose of this study was to investigate pedicle screw placement accuracy during navigated surgery by a junior spine surgeon who had no spinal surgery experience. A junior spine surgeon with no spinal surgery experience implanted a total of 137 pedicle screws by using a navigation system. Postoperative computerized tomography was performed to evaluate screw placement, and the pedicle perforation rate was 2.2%. There were no neurologic or vascular complications related to the pedicle screws. The results demonstrated that pedicle screws can be placed safely and effectively by a junior spine surgeon who has no spinal surgery experience when instructed by a senior spine surgeon. The results of this study suggest that navigation can be used as a surgical training tool for junior spine surgeons. (author)

  13. Enhanced biocompatibility and osseointegration of calcium titanate coating on titanium screws in rabbit femur.

    Science.gov (United States)

    Wang, Zi-Li; He, Rong-Zhen; Tu, Bin; Cao, Xu; He, Jin-Shen; Xia, Han-Song; Liang, Chi; Zou, Min; Wu, Song; Wu, Zhen-Jun; Xiong, Kun

    2017-06-01

    This study aimed to examine the biocompatibility of calcium titanate (CaTiO 3 ) coating prepared by a simplified technique in an attempt to assess the potential of CaTiO 3 coating as an alternative to current implant coating materials. CaTiO 3 -coated titanium screws were implanted with hydroxyapatite (HA)-coated or uncoated titanium screws into medial and lateral femoral condyles of 48 New Zealand white rabbits. Imaging, histomorphometric and biomechanical analyses were employed to evaluate the osseointegration and biocompatibility 12 weeks after the implantation. Histology and scanning electron microscopy revealed that bone tissues surrounding the screws coated with CaTiO 3 were fully regenerated and they were also well integrated with the screws. An interfacial fibrous membrane layer, which was found in the HA coating group, was not noticeable between the bone tissues and CaTiO 3 -coated screws. X-ray imaging analysis showed in the CaTiO 3 coating group, there was a dense and tight binding between implants and the bone tissues; no radiation translucent zone was found surrounding the implants as well as no detachment of the coating and femoral condyle fracture. In contrast, uncoated screws exhibited a fibrous membrane layer, as evidenced by the detection of a radiation translucent zone between the implants and the bone tissues. Additionally, biomechanical testing revealed that the binding strength of CaTiO 3 coating with bone tissues was significantly higher than that of uncoated titanium screws, and was comparable to that of HA coating. The study demonstrated that CaTiO 3 coating in situ to titanium screws possesses great biocompatibility and osseointegration comparable to HA coating.

  14. Edge screw withdrawal resistance in conventional particleboard and OSB: Influence of the particles type

    Directory of Open Access Journals (Sweden)

    Miljković Jovan

    2007-01-01

    Full Text Available This research was based on presumption that the changes in size and shape of wood particles are expected to have certain impact on the particleboard quality in general. Since the conventional particleboard (PB and oriented strand board (OSB were built of the quite diverse wood particles, they present interesting specimens in the comparison tests. In this work, the influence of the wood particles type on the edge screw holding performance of conventional particleboard and OSB was investigated. Those tests were obtained with the screw diameters of 4.0 mm, 4.5 mm and 5 mm. Depth of embedment was 30 mm for all tests and with the pilot-hole diameter kept in the range of 80-90% in respect of the screw root diameter. Additional tests of the thickness density profile and tensile strength perpendicular to the surface of the board were conducted. Since the middle layer structure of the particleboard embeds the screw body, both mentioned parameters are considered important in the aspect of the quality of the edge screw holding performance. In order to have further insight into the conformation of the middle layer the image survey was obtained on the split board section presenting the surface of the middle layer. Significant differences in the SWR performance of OSB and PB was recorded at all screw diameters. For the screw withdrawal tests parameters OSB samples showed 56-73% superior mean values then conventional PB. On the other hand, the OSB showed wider dispersions of measured withdrawal forces at all screw diameters, which might present some of the problems in certain engineering and project calculations.

  15. Percutaneous Cement-Augmented Screws Fixation in the Fractures of the Aging Spine: Is It the Solution?

    Directory of Open Access Journals (Sweden)

    Sébastien Pesenti

    2014-01-01

    Full Text Available Introduction. Management of elderly patients with thoracolumbar fractures is still challenging due to frequent osteoporosis and risk of screws pull-out. The aim of this study was to evaluate results of a percutaneous-only procedure to treat these fragile patients using cement-augmented screws. Methods. 12 patients diagnosed with a thoracolumbar fracture associated with an important loss of bone stock were included in this prospective study. Surgical procedure included systematically a percutaneous osteosynthesis using cemented fenestrated screws. When necessary, additional anterior support was performed using a kyphoplasty procedure. Clinical and radiographic evaluations were performed using CT scan. Results. On the whole series, 15 fractures were diagnosed and 96 cemented screws were inserted. The difference between the pre- and postoperative vertebral kyphosis was statistically significant (12.9° versus 4.4°, P=0.0006. No extrapedicular screw was reported and one patient was diagnosed with a cement-related pulmonary embolism. During follow-up period, no infectious complications, implant failures, or pull-out screws were noticed. Discussion. Aging spine is becoming an increasing public health issue. Management of these patients requires specific attention due to the augmented risk of complications. Using percutaneous-only screws fixation with cemented screw provides satisfactory results. A rigorous technique is mandatory in order to achieve best outcomes.

  16. In vivo degradation of a new concept of magnesium-based rivet-screws in the minipig mandibular bone

    Energy Technology Data Exchange (ETDEWEB)

    Schaller, Benoit [Department of Cranio-Maxillofacial Surgery, Inselspital, Bern University Hospital and University of Bern, CH-3010 Bern (Switzerland); National Dental Centre Singapore, 168938 (Singapore); Saulacic, Nikola [Department of Cranio-Maxillofacial Surgery, Inselspital, Bern University Hospital and University of Bern, CH-3010 Bern (Switzerland); Beck, Stefan, E-mail: SBECK2@its.jnj.com [Synthes Biomaterials, Eimattstr. 3, CH-4436 Oberdorf (Switzerland); Imwinkelried, Thomas [RMS Foundation, Bischmattstr. 12, CH-2544 Bettlach (Switzerland); Goh, Bee Tin [National Dental Centre Singapore, 168938 (Singapore); Nakahara, Ken [Department of Cranio-Maxillofacial Surgery, Inselspital, Bern University Hospital and University of Bern, CH-3010 Bern (Switzerland); Hofstetter, Willy [Department of Clinical Research, University of Bern, CH-3010 Bern (Switzerland); Iizuka, Tateyuki [Department of Cranio-Maxillofacial Surgery, Inselspital, Bern University Hospital and University of Bern, CH-3010 Bern (Switzerland)

    2016-12-01

    Self-tapping of magnesium screws in hard bone may be a challenge due to the limited torsional strength of magnesium alloys in comparison with titanium. To avoid screw failure upon implantation, the new concept of a rivet-screw was applied to a WE43 magnesium alloy. Hollow cylinders with threads on the outside were expanded inside drill holes of minipig mandibles. During the expansion with a hexagonal mandrel, the threads engaged the surrounding bone and the inside of the screw transformed into a hexagonal screw drive to allow further screwing in or out of the implant. The in vivo degradation of the magnesium implants and the performance of the used coating were studied in a human standard-sized animal model. Four magnesium alloy rivet-screws were implanted in each mandible of 12 minipigs. Six animals received the plasmaelectrolytically coated magnesium alloy implants; another six received the uncoated magnesium alloy rivet-screws. Two further animals received one titanium rivet-screw each as control. In vivo radiologic examination was performed at one, four, and eight weeks. Euthanasia was performed for one group of seven animals (three animals with coated, three with uncoated magnesium alloy implants and one with titanium implant) at 12 weeks and for the remaining seven animals at 24 weeks. After euthanasia, micro-computed tomography and histological examination with histomorphometry were performed. Significantly less void formation as well as higher bone volume density (BV/TV) and bone-implant contact area (BIC) were measured around the coated implants compared to the uncoated ones. The surface coating was effective in delaying degradation despite plastic deformation. The results showed potential for further development of magnesium hollow coated screws for bone fixation. - Highlights: • A new concept of rivet screws as an alternative to classical screws is presented • The rivet screw concept was tested in vivo in a mini-pig pilot study • Un-coated and

  17. In vivo degradation of a new concept of magnesium-based rivet-screws in the minipig mandibular bone

    International Nuclear Information System (INIS)

    Schaller, Benoit; Saulacic, Nikola; Beck, Stefan; Imwinkelried, Thomas; Goh, Bee Tin; Nakahara, Ken; Hofstetter, Willy; Iizuka, Tateyuki

    2016-01-01

    Self-tapping of magnesium screws in hard bone may be a challenge due to the limited torsional strength of magnesium alloys in comparison with titanium. To avoid screw failure upon implantation, the new concept of a rivet-screw was applied to a WE43 magnesium alloy. Hollow cylinders with threads on the outside were expanded inside drill holes of minipig mandibles. During the expansion with a hexagonal mandrel, the threads engaged the surrounding bone and the inside of the screw transformed into a hexagonal screw drive to allow further screwing in or out of the implant. The in vivo degradation of the magnesium implants and the performance of the used coating were studied in a human standard-sized animal model. Four magnesium alloy rivet-screws were implanted in each mandible of 12 minipigs. Six animals received the plasmaelectrolytically coated magnesium alloy implants; another six received the uncoated magnesium alloy rivet-screws. Two further animals received one titanium rivet-screw each as control. In vivo radiologic examination was performed at one, four, and eight weeks. Euthanasia was performed for one group of seven animals (three animals with coated, three with uncoated magnesium alloy implants and one with titanium implant) at 12 weeks and for the remaining seven animals at 24 weeks. After euthanasia, micro-computed tomography and histological examination with histomorphometry were performed. Significantly less void formation as well as higher bone volume density (BV/TV) and bone-implant contact area (BIC) were measured around the coated implants compared to the uncoated ones. The surface coating was effective in delaying degradation despite plastic deformation. The results showed potential for further development of magnesium hollow coated screws for bone fixation. - Highlights: • A new concept of rivet screws as an alternative to classical screws is presented • The rivet screw concept was tested in vivo in a mini-pig pilot study • Un-coated and

  18. Tidal locking of habitable exoplanets

    Science.gov (United States)

    Barnes, Rory

    2017-12-01

    Potentially habitable planets can orbit close enough to their host star that the differential gravity across their diameters can produce an elongated shape. Frictional forces inside the planet prevent the bulges from aligning perfectly with the host star and result in torques that alter the planet's rotational angular momentum. Eventually the tidal torques fix the rotation rate at a specific frequency, a process called tidal locking. Tidally locked planets on circular orbits will rotate synchronously, but those on eccentric orbits will either librate or rotate super-synchronously. Although these features of tidal theory are well known, a systematic survey of the rotational evolution of potentially habitable exoplanets using classic equilibrium tide theories has not been undertaken. I calculate how habitable planets evolve under two commonly used models and find, for example, that one model predicts that the Earth's rotation rate would have synchronized after 4.5 Gyr if its initial rotation period was 3 days, it had no satellites, and it always maintained the modern Earth's tidal properties. Lower mass stellar hosts will induce stronger tidal effects on potentially habitable planets, and tidal locking is possible for most planets in the habitable zones of GKM dwarf stars. For fast-rotating planets, both models predict eccentricity growth and that circularization can only occur once the rotational frequency is similar to the orbital frequency. The orbits of potentially habitable planets of very late M dwarfs ([InlineEquation not available: see fulltext.]) are very likely to be circularized within 1 Gyr, and hence, those planets will be synchronous rotators. Proxima b is almost assuredly tidally locked, but its orbit may not have circularized yet, so the planet could be rotating super-synchronously today. The evolution of the isolated and potentially habitable Kepler planet candidates is computed and about half could be tidally locked. Finally, projected TESS planets

  19. Multiprocessor Real-Time Locking Protocols for Replicated Resources

    Science.gov (United States)

    2016-07-01

    assignment problem, the ac- tual identities of the allocated replicas must be known. When locking protocols are used, tasks may experience delays due to both...Multiprocessor Real-Time Locking Protocols for Replicated Resources ∗ Catherine E. Jarrett1, Kecheng Yang1, Ming Yang1, Pontus Ekberg2, and James H...replicas to execute. In prior work on replicated resources, k-exclusion locks have been used, but this restricts tasks to lock only one replica at a time. To

  20. Locking of intrinsic angular momentum in collision complexes

    International Nuclear Information System (INIS)

    Berengolts, Alexander.

    1995-04-01

    A concept of locking of the intrinsic angular momentum of a fragment of a collision complex to a body-fixed axis is widely used in the description of heavy-particle dynamics. The aim of this work is to provide a semiclassical description of the locking phenomenon which occur in diatomic and three atomic collision complexes. The first part of this work is devoted to the semiclassical study of the locking of the electronic angular momentum that occurs in slow collisions of two atoms, one in the spherically symmetric state and the other in state with j= 1. Here we calculate explicitly the complete locking matrix for different types of interatomic interactions. The elements of this matrix directly enter into the semiclassical expression for the different cross sections of polarized atoms. Limitations to the notion of the the locking radius and slipping probability are discussed in connection with the steepness of the interaction. Numerical calculations confirm analytical result: the optimal criterion for determination of the locking radius is a condition for the accumulated phase difference between two molecular states. Analytical expressions are suggested for the locking angle and the slipping probability. Implication of the locking approximation for calculation of the quasiclassical scattering matrix is discussed. The second part considers the locking of the rotational angular momentum of a diatom in the decomposition of a triatomic complexes. We discuss here cases J = 1,2,3 and 4, but restrict ourselves to calculation of the so-called dynamic orientation of the diatomic fragment. The letter represents one of the characteristics of the locking matrix which in principle can be measured experimentally. The orientation is created as a result of the interplay between the adiabatic interaction in the atom- diatom exit channel and the rotationally non adiabatic coupling in the perturbed rotor region

  1. Screwing or unscrewing device for studs or bolls of big dimension

    International Nuclear Information System (INIS)

    Sevelinge, G.; Bourdonne, J.C.

    1988-01-01

    The device for screwing or unscrewing large studs or bolts has a system determining the optimun screwing position and orientation of the bolt, a variable speed bidirectional drive a pin holding the bolt axially and system compensating the weight of the bolt with an hydraulic jack with a pressure detector to which the drive is slaved [fr

  2. On damping of screw dislocation bending vibrations in dissipative crystal: limiting cases

    Science.gov (United States)

    Dezhin, V. V.

    2018-03-01

    The expression for the generalized susceptibility of the dislocation obtained earlier was used. The electronic drag mechanism of dislocations is considered. The study of small dislocation oscillations was limited. The contribution of the attenuation of low-frequency bending screw dislocation vibrations to the overall coefficient of dynamic dislocation drag in the long-wave and short-wave limits is calculated. The damping of short-wave bending screw dislocation vibrations caused by an external action of an arbitrary frequency has been investigated. The contribution of long-wave bending screw dislocation vibrations damping in the total drag coefficient at an arbitrary frequency is found.

  3. Injection locking of optomechanical oscillators via acoustic waves.

    Science.gov (United States)

    Huang, Ke; Hossein-Zadeh, Mani

    2018-04-02

    Injection locking is an effective technique for synchronization of oscillator networks and controlling the phase and frequency of individual oscillators. As such, exploring new mechanisms for injection locking of emerging oscillators is important for their usage in various systems. Here, we present the first demonstration of injection locking of a radiation pressure driven optomechanical oscillator (OMO) via acoustic waves. As opposed to previously reported techniques (based on pump modulation or direct application of a modulated electrostatic force), injection locking of OMO via acoustic waves does not require optical power modulation or physical contact with the OMO and it can be easily implemented on various platforms to lock different types of OMOs independent of their size and structure. Using this approach we have locked the phase and frequency of two distinct modes of a microtoroidal silica OMO to a piezoelectric transducer (PZT). We have characterized the behavior of the injection locked OMO with three acoustic excitation configurations and showed that even without proper acoustic impedance, matching the OMO can be locked to the PZT and tuned over 17 kHz with only -30 dBm of RF power fed to the PZT. The high efficiency, simplicity, and scalability of the proposed approach paves the road toward a new class of photonic systems that rely on synchronization of several OMOs to a single or multiple RF oscillators with applications in optical communication, metrology, and sensing. Beyond its practical applications, injection locking via acoustic waves can be used in fundamental studies in quantum optomechanics where thermal and optical isolation of the OMO are critical.

  4. Chirality-controlled crystallization via screw dislocations.

    Science.gov (United States)

    Sung, Baeckkyoung; de la Cotte, Alexis; Grelet, Eric

    2018-04-11

    Chirality plays an important role in science from enantiomeric separation in chemistry to chiral plasmonics in nanotechnology. However, the understanding of chirality amplification from chiral building blocks to ordered helical superstructures remains a challenge. Here, we demonstrate that topological defects, such as screw dislocations, can drive the chirality transfer from particle to supramolecular structure level during the crystallization process. By using a model system of chiral particles, which enables direct imaging of single particle incorporation into growing crystals, we show that the crystallization kinetic pathway is the key parameter for monitoring, via the defects, the chirality amplification of the crystalline structures from racemic to predominantly homohelical. We provide an explanation based on the interplay between geometrical frustration, racemization induced by thermal fluctuations, and particle chirality. Our results demonstrate that screw dislocations not only promote the growth, but also control the chiral morphology and therefore the functionality of crystalline states.

  5. Thermodynamic performance of multi-stage gradational lead screw vacuum pump

    Science.gov (United States)

    Zhao, Fan; Zhang, Shiwei; Sun, Kun; Zhang, Zhijun

    2018-02-01

    As a kind of dry mechanical vacuum pump, the twin-screw vacuum pump has an outstanding pumping performance during operation, widely used in the semiconductor industry. Compared with the constant lead screw (CLS) vacuum pump, the gradational lead screw (GLS) vacuum pump is more popularly applied in recent years. Nevertheless, not many comparative studies on the thermodynamic performance of GLS vacuum pump can be found in the literature. Our study focuses on one type of GLS vacuum pump, the multi-stage gradational lead screw (MGLS) vacuum pump, gives a detailed description of its construction and illustrates it with the drawing. Based on the structural analysis, the thermodynamic procedure is divided into four distinctive processes, including sucking process, transferring (compressing) process, backlashing process and exhausting process. The internal mechanism of each process is qualitatively illustrated and the mathematical expressions of seven thermodynamic parameters are given under the ideal situation. The performance curves of MGLS vacuum pump are plotted by MATLAB software and compared with those of the CLS vacuum pump in the same case. The results can well explain why the MGLS vacuum pump has more favorable pumping performance than the CLS vacuum pump in saving energy, reducing noise and heat dissipation.

  6. Unified Symmetry of Hamilton Systems

    International Nuclear Information System (INIS)

    Xu Xuejun; Qin Maochang; Mei Fengxiang

    2005-01-01

    The definition and the criterion of a unified symmetry for a Hamilton system are presented. The sufficient condition under which the Noether symmetry is a unified symmetry for the system is given. A new conserved quantity, as well as the Noether conserved quantity and the Hojman conserved quantity, deduced from the unified symmetry, is obtained. An example is finally given to illustrate the application of the results.

  7. No Snowball on Habitable Tidally Locked Planets

    Science.gov (United States)

    Checlair, Jade; Menou, Kristen; Abbot, Dorian S.

    2017-08-01

    The TRAPPIST-1, Proxima Centauri, and LHS 1140 systems are the most exciting prospects for future follow-up observations of potentially inhabited planets. All of the planets orbit nearby M-stars and are likely tidally locked in 1:1 spin–orbit states, which motivates the consideration of the effects that tidal locking might have on planetary habitability. On Earth, periods of global glaciation (snowballs) may have been essential for habitability and remote signs of life (biosignatures) because they are correlated with increases in the complexity of life and in the atmospheric oxygen concentration. In this paper, we investigate the snowball bifurcation (sudden onset of global glaciation) on tidally locked planets using both an energy balance model and an intermediate-complexity global climate model. We show that tidally locked planets are unlikely to exhibit a snowball bifurcation as a direct result of the spatial pattern of insolation they receive. Instead, they will smoothly transition from partial to complete ice coverage and back. A major implication of this work is that tidally locked planets with an active carbon cycle should not be found in a snowball state. Moreover, this work implies that tidally locked planets near the outer edge of the habitable zone with low CO2 outgassing fluxes will equilibrate with a small unglaciated substellar region rather than cycling between warm and snowball states. More work is needed to determine how the lack of a snowball bifurcation might affect the development of life on a tidally locked planet.

  8. No Snowball on Habitable Tidally Locked Planets

    International Nuclear Information System (INIS)

    Checlair, Jade; Abbot, Dorian S.; Menou, Kristen

    2017-01-01

    The TRAPPIST-1, Proxima Centauri, and LHS 1140 systems are the most exciting prospects for future follow-up observations of potentially inhabited planets. All of the planets orbit nearby M-stars and are likely tidally locked in 1:1 spin–orbit states, which motivates the consideration of the effects that tidal locking might have on planetary habitability. On Earth, periods of global glaciation (snowballs) may have been essential for habitability and remote signs of life (biosignatures) because they are correlated with increases in the complexity of life and in the atmospheric oxygen concentration. In this paper, we investigate the snowball bifurcation (sudden onset of global glaciation) on tidally locked planets using both an energy balance model and an intermediate-complexity global climate model. We show that tidally locked planets are unlikely to exhibit a snowball bifurcation as a direct result of the spatial pattern of insolation they receive. Instead, they will smoothly transition from partial to complete ice coverage and back. A major implication of this work is that tidally locked planets with an active carbon cycle should not be found in a snowball state. Moreover, this work implies that tidally locked planets near the outer edge of the habitable zone with low CO 2 outgassing fluxes will equilibrate with a small unglaciated substellar region rather than cycling between warm and snowball states. More work is needed to determine how the lack of a snowball bifurcation might affect the development of life on a tidally locked planet.

  9. A modified transcondylar screw to accommodate anatomical skull base variations.

    Science.gov (United States)

    Ghaly, R F; Lissounov, A

    2017-01-01

    Occipitocervical instability may be attributed to congenital, bony/ligamentous abnormalities, trauma, neoplasm, degenerative bone disease, and failed atlantoaxial fixation. Indications for occipitocervical fixation include the prevention of disabling pain, cranial nerve dysfunction, paralysis, or even sudden death. The screw trajectory for the modified transcondylar screw (mTCS) is optimally planned utilizing a three-dimensional skull reconstructed image. The modified mTCS technique is helpful where there is a loss of bone, such as after prior suboccipital craniotomy and/or an inadequate occipital condyle. The new proposed technique is similar to the classical transcondylar screw placement but follows a deeper course along the bony lip of foramen magnum toward clivus from a dorsolateral approach. The modified mTCS technique allows for direct visualization and, therefore, helps to avoid damage to the hypoglossal nerve and lateral aspect of brain stem.

  10. The value of 18F-fluoride PET/CT in the assessment of screw loosening in patients after intervertebral fusion stabilization

    International Nuclear Information System (INIS)

    Seifen, Tanja; Rodrigues, Margarida; Rettenbacher, Lukas; Holzmannhofer, Johannes; Pirich, Christian; Piotrowski, Wolfgang; Mc Coy, Mark

    2015-01-01

    We evaluated 18 F-fluoride PET/CT for the diagnosis of screw loosening after intervertebral fusion stabilization and compared the results with those from functional radiography. A group of 59 patients with pain in the region of previous intervertebral fusion stabilization and suspicion of implant instability due to screw loosening were investigated with 18 F-fluoride PET/CT and functional radiography, 30.1 ± 3.4 and 29.3 ± 3.2 months, respectively, after surgery. The criterion for loosening was increased focal uptake surrounding the screw entry point and shaft. SUV max and SUV mean were measured in a region of interest (ROI) drawn around each screw (334 screws analysed). The final diagnosis was established by surgical exploration in 27 patients and clinical follow-up after intervertebral fusion stabilization in 32 patients. Of the 59 patients, 20 were proven positive for implant failure due to screw loosening and 39 were confirmed negative. The sensitivity, specificity and accuracy of 18 F-fluoride PET/CT were 75 %, 97.4 % and 89.8 % in the patient-based analysis, and 45.6 %, 100 % and 80 % in the screw-based analysis, respectively. The positive and negative predictive values were 93.8 % and 100 % in the patient-based analysis, and 88.4 and 76 % in the screw-based analysis, respectively. CT signs in PET/CT allowed screw breakage to be detected in three patients. SUV max , SUV mean and SUV max /SUV mean ratios in screw ROIs and respective values in reference regions were all found to be significantly different between screws positive for loosening (58 screws) and screws negative for loosening (276 screws). The ratio between SUV max in screw ROIs and the values in reference regions was the most significant parameter for distinguishing screws positive and screws negative for loosening. 18 F-Fluoride PET/CT imaging is useful for the diagnosis of screw loosening in patients with persistent symptoms after intervertebral fusion stabilization. (orig.)

  11. Ipsilateral proximal femur and shaft fractures treated with hip screws and a reamed retrograde intramedullary nail.

    Science.gov (United States)

    Ostrum, Robert F; Tornetta, Paul; Watson, J Tracy; Christiano, Anthony; Vafek, Emily

    2014-09-01

    Although not common, proximal femoral fractures associated with ipsilateral shaft fractures present a difficult management problem. A variety of surgical options have been employed with varying results. We investigated the use of hip screws and a reamed retrograde intramedullary (IM) nail for the treatment of this combined fracture pattern in terms of postoperative alignment (malunion), nonunion, and complications. Between May 2002 and October 2011, a total of 95 proximal femoral fractures with associated shaft fractures were treated at three participating Level 1 trauma centers; all were treated with hip screw fixation (cannulated screws or sliding hip screws) and retrograde reamed IM nails. The medical records of these patients were reviewed retrospectively for alignment, malunion, nonunion, and complications. Followup was available on 92 of 95 (97%) of the patients treated with hip screws and a retrograde nail. Forty were treated with a sliding hip screw, and 52 were treated with cannulated screws. There were five proximal malunions in this series (5%). The union rate was 98% (90 of 92) for the femoral neck fractures and 91.3% (84 of 92) for the femoral shaft fractures after the initial surgery. There were two nonunions of comminuted femoral neck fractures after cannulated screw fixation. There was no difference in femoral neck union or alignment when comparing cannulated screws to a sliding hip screw. Four open comminuted femoral shaft fractures went on to nonunion and required secondary surgery to obtain union, and one patient developed symptomatic avascular necrosis. The treatment of ipsilateral proximal femoral neck and shaft fractures with hip screw fixation and a reamed retrograde nail demonstrated a high likelihood of union for the femoral neck fractures and a low risk of malunion. Comminution and initial displacement of the proximal femoral fracture may still lead to a small incidence of malunion or nonunion, and open comminuted femoral shaft fractures

  12. Screw-in forces during instrumentation by various file systems.

    Science.gov (United States)

    Ha, Jung-Hong; Kwak, Sang Won; Kim, Sung-Kyo; Kim, Hyeon-Cheol

    2016-11-01

    The purpose of this study was to compare the maximum screw-in forces generated during the movement of various Nickel-Titanium (NiTi) file systems. Forty simulated canals in resin blocks were randomly divided into 4 groups for the following instruments: Mtwo size 25/0.07 (MTW, VDW GmbH), Reciproc R25 (RPR, VDW GmbH), ProTaper Universal F2 (PTU, Dentsply Maillefer), and ProTaper Next X2 (PTN, Dentsply Maillefer, n = 10). All the artificial canals were prepared to obtain a standardized lumen by using ProTaper Universal F1. Screw-in forces were measured using a custom-made experimental device (AEndoS- k , DMJ system) during instrumentation with each NiTi file system using the designated movement. The rotation speed was set at 350 rpm with an automatic 4 mm pecking motion at a speed of 1 mm/sec. The pecking depth was increased by 1 mm for each pecking motion until the file reach the working length. Forces were recorded during file movement, and the maximum force was extracted from the data. Maximum screw-in forces were analyzed by one-way ANOVA and Tukey's post hoc comparison at a significance level of 95%. Reciproc and ProTaper Universal files generated the highest maximum screw-in forces among all the instruments while M-two and ProTaper Next showed the lowest ( p files with smaller cross-sectional area for higher flexibility is recommended.

  13. Computer-assisted surgery for screw insertion into the distal sesamoid bone in horses: an in vitro study.

    Science.gov (United States)

    Gygax, Diego; Lischer, Christoph; Auer, Joerg A

    2006-10-01

    To compare the precision of computer-assisted surgery with a conventional technique (CV) using a special guiding device for screw insertion into the distal sesamoid bone in horses. In vitro experimental study. Cadaveric forelimb specimens. Insertion of a 3.5 mm cortex screw in lag fashion along the longitudinal axis of intact (non-fractured) distal sesamoid bones was evaluated in 2 groups (8 limbs each): CV and computer-assisted surgery (CAS). For CV, the screw was inserted using a special guiding device and fluoroscopy, whereas for CAS, the screw was inserted using computer-assisted navigation. The accuracy of screw placement was verified by radiography, computed tomography, and specimen dissection. Surgical precision was better in CAS compared with CV. CAS improves the accuracy of lateromedial screw insertion, in lag fashion, into the distal sesamoid bone. The CAS technique should be considered for improved accuracy of screw insertion in fractures of the distal sesamoid bone.

  14. Radiographic study of the fifth metatarsal for optimal intramedullary screw fixation of Jones fracture.

    Science.gov (United States)

    Ochenjele, George; Ho, Bryant; Switaj, Paul J; Fuchs, Daniel; Goyal, Nitin; Kadakia, Anish R

    2015-03-01

    Jones fractures occur in the relatively avascular metadiaphyseal junction of the fifth metatarsal (MT), which predisposes these fractures to delayed union and nonunion. Operative treatment with intramedullary (IM) screw fixation is recommended in certain cases. Incorrect screw selection can lead to refractures, nonunion, and cortical blowout fractures. A better understanding of the anatomy of the fifth MT could aid in preoperative planning, guide screw size selection, and minimize complications. We retrospectively identified foot computed tomographic (CT) scans of 119 patients that met inclusion criteria. Using interactive 3-dimensional (3-D) models, the following measurements were calculated: MT length, "straight segment length" (distance from the base of the MT to the shaft curvature), and canal diameter. The diaphysis had a lateroplantar curvature where the medullary canal began to taper. The average straight segment length was 52 mm, and corresponded to 68% of the overall length of the MT from its proximal end. The medullary canal cross-section was elliptical rather than circular, with widest width in the sagittal plane and narrowest in coronal plane. The average coronal canal diameter at the isthmus was 5.0 mm. A coronal diameter greater than 4.5 mm at the isthmus was present in 81% of males and 74% of females. To our knowledge, this is the first anatomic description of the fifth metatarsal based on 3-D imaging. Excessive screw length could be avoided by keeping screw length less than 68% of the length of the fifth metatarsal. A greater than 4.5 mm diameter screw might be needed to provide adequate fixation for most study patients since the isthmus of the medullary canal for most were greater than 4.5 mm. Our results provide an improved understanding of the fifth metatarsal anatomy to guide screw diameter and length selection to maximize screw fixation and minimize complications. © The Author(s) 2014.

  15. Idealized Compression Ratio for a Screw Briquetting Press

    Directory of Open Access Journals (Sweden)

    Peter Biath

    2012-01-01

    Full Text Available This paper deals with issues in determining the ideal compression ratio for a screw briquetting press. First, the principles of operation and a basic description of the main parts of a screw briquetting press are introduced. The next section describes the pressing space by means of 3D software. The pressing space was created using a Boolean subtract function. The final section of the paper measures the partial volumes of the pressing chamber in CATIA V5 by function of measuring. The measured values are substituted into the formula for the compression ratio, and the resulting evaluations are presented in the diagram in the conclusion of this paper.

  16. Usefulness and radiological evaluation of accuracy of innovative "Smart" hand technique for pedicle screw placement: an anatomical study.

    Science.gov (United States)

    Comert, Ayhan; Dogan, İhsan; Çaglar, Y Sukru

    2017-11-01

    The aim of this study is to use a smartphone application during pedicle screw placement navigation and examine the accuracy of this application on anatomical dry vertebrae model. 76 dry vertebrae were used for this study and pedicle entry points, projections of pedicle screw trajectory lines in lateral and superior aspect of vertebral body were identified and drawn for each vertebra bilaterally. In each position, all angulations were measured directly before the procedure manually. 152 pedicle screws were inserted as a simulation of screw placement with the guidance of angle-meter smart app. Accuracy of the method was tested according to the occurrence of bone penetration and angular deviation of the inserted screws was evaluated in computed tomography images. Mean deviation of pedicle screws of 76 pedicle screws in right side in horizontal plane was measured 2.30°±1.78°; in sagittal plane 2.17°±1.57° and in left side in horizontal plane 3.01°±1.83°; in sagittal plane 2.38°±1.68°. No bone penetration was occurred during 152 pedicle screw placements. According to the t-test results, there were significant differences between two groups in craniocaudal direction of the right side pedicle screws and in craniocaudal direction of left side pedicle screws. The free smartphone application presented here as angle-meter can be interpreted as a safe digital device for spinal instrumentation procedures. As a prototype of future pedicle screw fixation systems, it should be improved in terms of its feasibility and compatibility with screw probes. This may lead to apply mobile digital angle meter in spinal procedure.

  17. Risks to the Superior Gluteal Neurovascular Bundle During Iliosacral and Transsacral Screw Fixation: A Computed Tomogram Arteriography Study.

    Science.gov (United States)

    Maslow, Jed; Collinge, Cory A

    2017-12-01

    Iliosacral (IS) and transsacral (TS) screws are popular techniques to repair complicated injuries to the pelvis. The anatomy of the superior gluteal neurovasculature (SG NV bundle) is well described as running along the posterior ilium, providing innervation and perfusion to important abductor muscles. The method of pelvis fixation least likely to injure the SG NV bundle is unknown. Twenty uninjured patients with a contrasted computed tomogram of the pelvis and lower extremities (CTA) were evaluated. Starting points for an S1 IS screw and S1 and S2 TS screws were estimated on the "ghost" lateral CTA image for those pelvi with safe corridors (>9 mm diameter). The distance from the projected screw to the SG artery was measured. A distance of <3.65 mm (half of a 7.3-mm screw's diameter) was considered likely for NV bundle injury. Of 40 pelvi CTAs (single sides), 10 pelvi (25%) were determined to be inappropriate for an S1 TS screw. The average distances from the screw starting point and the artery were 25.3 mm (±9.2) for S1 IS, 12.4 mm (±9.0) for S1 TS, and 23.5 mm (±10.7) for S2 TS screws, respectively. Ten S1 TS screws (25%) and no S1 IS or S2 TS screws were projected to have caused injury to the SG NV bundle (P < 0.001). Inserting S1 IS and S2 TS screws put the SG NV anatomy at significantly less risk than S1 TS screws. This information may aid in choosing the "best" fixation option for patients with pelvic ring trauma requiring surgery.

  18. Commonwealth Edison Company pressure locking test report

    Energy Technology Data Exchange (ETDEWEB)

    Bunte, B.D.; Kelly, J.F.

    1996-12-01

    Pressure Locking is a phenomena which can cause the unseating thrust for a gate valve to increase dramatically from its typical static unseating thrust. This can result in the valve actuator having insufficient capability to open the valve. In addition, this can result in valve damage in cases where the actuator capability exceeds the valve structural limits. For these reasons, a proper understanding of the conditions which may cause pressure locking and thermal binding, as well as a methodology for predicting the unseating thrust for a pressure locked or thermally bound valve, are necessary. This report discusses the primary mechanisms which cause pressure locking. These include sudden depressurization of piping adjacent to the valve and pressurization of fluid trapped in the valve bonnet due to heat transfer. This report provides a methodology for calculating the unseating thrust for a valve which is pressure locked. This report provides test data which demonstrates the accuracy of the calculation methodology.

  19. Commonwealth Edison Company pressure locking test report

    International Nuclear Information System (INIS)

    Bunte, B.D.; Kelly, J.F.

    1996-01-01

    Pressure Locking is a phenomena which can cause the unseating thrust for a gate valve to increase dramatically from its typical static unseating thrust. This can result in the valve actuator having insufficient capability to open the valve. In addition, this can result in valve damage in cases where the actuator capability exceeds the valve structural limits. For these reasons, a proper understanding of the conditions which may cause pressure locking and thermal binding, as well as a methodology for predicting the unseating thrust for a pressure locked or thermally bound valve, are necessary. This report discusses the primary mechanisms which cause pressure locking. These include sudden depressurization of piping adjacent to the valve and pressurization of fluid trapped in the valve bonnet due to heat transfer. This report provides a methodology for calculating the unseating thrust for a valve which is pressure locked. This report provides test data which demonstrates the accuracy of the calculation methodology

  20. Chitosan-coated Stainless Steel Screws for Fixation in Contaminated Fractures

    OpenAIRE

    Greene, Alex H.; Bumgardner, Joel D.; Yang, Yunzhi; Moseley, Jon; Haggard, Warren O.

    2008-01-01

    Stainless steel screws and other internal fixation devices are used routinely to stabilize bacteria-contaminated bone fractures from multiple injury mechanisms. In this preliminary study, we hypothesize that a chitosan coating either unloaded or loaded with an antibiotic, gentamicin, could lessen or prevent these devices from becoming an initial nidus for infection. The questions investigated for this hypothesis were: (1) how much of the sterilized coating remains on the screw with simulated ...

  1. Energy saving screw compressor technology; Energiebesparende schroefcompressortechnologie

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, A. [RefComp, Lonigo (Italy); Neus, M. [Delta Technics Engineering, Breda (Netherlands)

    2011-03-15

    Smart solutions to reduce the energy consumption are continuously part of investigation in the refrigeration technology. This article subscribed the technology on which way energy can be saved at the operation of screw compressors which are used in air conditioners and refrigerating machinery. The combination of frequency control and Vi-control (intrinsic volumetric ratio) such as researched in the laboratory of RefComp is for the user attractive because the energy efficiency during part load operation is much better. Smart uses of thermodynamics, electric technology and electronic control are the basics of these applications. According to the manufacturer's information it is possible with these new generation screw compressors to save approx. 26% energy in comparison with the standard screw compressor. [Dutch] In dit artikel wordt de technologie omschreven waarmee veel energie bespaard kan worden bij schroefcompressoren die worden gebruikt in airconditioningsystemen en koel- en vriesinstallaties. De combinatie van frequentieregeling en Vi- regeling (Vi is de intrinsieke volumetrische verhouding) zoals onderzocht in het laboratorium van RefComp biedt de gebruiker veel voordelen doordat de energie-efficintie van de compressor tijdens deellast enorm wordt verbeterd. Slim gebruik van thermodynamika, elektrotechniek en elektronica vormen de basis van deze toepassing. Volgens de fabrikant kan met deze nieuwe generatie schroefcompressoren circa 26 procent op het energiegebruik tijdens deellast worden bespaard in vergelijking met de standaard serie schroefcompressoren.

  2. d = 2 transverse-field Ising model under the screw-boundary condition: an optimization of the screw pitch

    International Nuclear Information System (INIS)

    Nishiyama, Yoshihiro

    2011-01-01

    A length-N spin chain with the √N(=v)th neighbor interaction is identical to a two-dimensional (d = 2) model under the screw-boundary (SB) condition. The SB condition provides a flexible scheme to construct a d ≥ 2 cluster from an arbitrary number of spins; the numerical diagonalization combined with the SB condition admits a potential applicability to a class of systems intractable with the quantum Monte Carlo method due to the negative-sign problem. However, the simulation results suffer from characteristic finite-size corrections inherent in SB. In order to suppress these corrections, we adjust the screw pitch v(N) so as to minimize the excitation gap for each N. This idea is adapted to the transverse-field Ising model on the triangular lattice with N ≤ 32 spins. As a demonstration, the correlation-length critical exponent ν is analyzed in some detail

  3. Perturbation effects of the carbon fiber-PEEK screws on radiotherapy dose distribution.

    Science.gov (United States)

    Nevelsky, Alexander; Borzov, Egor; Daniel, Shahar; Bar-Deroma, Raquel

    2017-03-01

    Radiation therapy, in conjunction with surgical implant fixation, is a common combined treatment in cases of bone metastases. However, metal implants generally used in orthopedic implants perturb radiation dose distributions. Carbon-Fiber Reinforced Polyetheretherketone (CFR-PEEK) material has been recently introduced for production of intramedullary nails and plates. The purpose of this work was to investigate the perturbation effects of the new CFR-PEEK screws on radiotherapy dose distributions and to evaluate these effects in comparison with traditional titanium screws. The investigation was performed by means of Monte Carlo (MC) simulations for a 6 MV photon beam. The project consisted of two main stages. First, a comparison of measured and MC calculated doses was performed to verify the validity of the MC simulation results for different materials. For this purpose, stainless steel, titanium, and CFR-PEEK plates of various thicknesses were used for attenuation and backscatter measurements in a solid water phantom. For the same setup, MC dose calculations were performed. Next, MC dose calculations for titanium, CFR-PEEK screws, and CFR-PEEK screws with ultrathin titanium coating were performed. For the plates, the results of our MC calculations for all materials were found to be in good agreement with the measurements. This indicates that the MC model can be used for calculation of dose perturbation effects caused by the screws. For the CFR-PEEK screws, the maximum dose perturbation was less than 5%, compared to more than 30% perturbation for the titanium screws. Ultrathin titanium coating had a negligible effect on the dose distribution. CFR-PEEK implants have good prospects for use in radiotherapy because of minimal dose alteration and the potential for more accurate treatment planning. This could favorably influence treatment efficiency and decrease possible over- and underdose of adjacent tissues. The use of such implants has potential clinical advantages

  4. Accuracy of percutaneous pedicle screws for thoracic and lumbar spine fractures compared with open technique.

    Science.gov (United States)

    Paredes, Igor; Panero, Irene; Cepeda, Santiago; Castaño-Leon, Ana M; Jimenez-Roldan, Luis; Perez-Nuñez, Ángel; Alén, Jose A; Lagares, Alfonso

    2018-06-14

    This study aimed to compare the accuracy of screw placement between open pedicle screw fixation and percutaneous pedicle screw fixation (MIS) for the treatment of thoracolumbar spine fractures (TSF). Forty-nine patients with acute TSF who were treated with transpedicular screw fixation from January 2013 to December 2016 were retrospectively reviewed. The patients were divided into Open and MIS groups. Laminectomy was performed in either group if needed. The accuracy of the screw placement, the evolution of the Cobb sagital angle postoperatively and at 12-month follow up and the neurological status were recorded. AO type of fracture and TLICS score were also recorded. Mean age was 42 years old. Mean TLICS score was 6,29 and 5,96 for open and MIS groups respectively. Twenty five MIS and 24 open surgeries were performed, and 350 (175 in each group) screws were inserted (7,14 per patient). Twenty-four and 13 screws were considered ̈out ̈ in the open and MIS groups respectively (Odds ratio 1,98. 0,97-4,03 p=0,056). The Cobb sagittal angle went from 13,3o to 4,5o and from 14,9o to 8,2o in the Open and MIS groups respectively (both popen and MIS groups respectively. No neurological worsening was observed. For the treatment of acute thoracolumbar fractures, the MIS technique seems to achieve similar results to the open technique in relation to neurological improvement and deformity correction, while placing the screws more accurately.

  5. Thermal Analysis of Ball screw Systems by Explicit Finite Difference Method

    Energy Technology Data Exchange (ETDEWEB)

    Min, Bog Ki [Hanyang Univ., Seoul (Korea, Republic of); Park, Chun Hong; Chung, Sung Chong [KIMM, Daejeon (Korea, Republic of)

    2016-01-15

    Friction generated from balls and grooves incurs temperature rise in the ball screw system. Thermal deformation due to the heat degrades positioning accuracy of the feed drive system. To compensate for the thermal error, accurate prediction of the temperature distribution is required first. In this paper, to predict the temperature distribution according to the rotational speed, solid and hollow cylinders are applied for analysis of the ball screw shaft and nut, respectively. Boundary conditions such as the convective heat transfer coefficient, friction torque, and thermal contact conductance (TCC) between balls and grooves are formulated according to operating and fabrication conditions of the ball screw. Explicit FDM (finite difference method) is studied for development of a temperature prediction simulator. Its effectiveness is verified through numerical analysis.

  6. Power Quality Improvement by Unified Power Quality Conditioner Based on CSC Topology Using Synchronous Reference Frame Theory

    Directory of Open Access Journals (Sweden)

    Rajasekaran Dharmalingam

    2014-01-01

    Full Text Available This paper deals with the performance of unified power quality conditioner (UPQC based on current source converter (CSC topology. UPQC is used to mitigate the power quality problems like harmonics and sag. The shunt and series active filter performs the simultaneous elimination of current and voltage problems. The power fed is linked through common DC link and maintains constant real power exchange. The DC link is connected through the reactor. The real power supply is given by the photovoltaic system for the compensation of power quality problems. The reference current and voltage generation for shunt and series converter is based on phase locked loop and synchronous reference frame theory. The proposed UPQC-CSC design has superior performance for mitigating the power quality problems.

  7. Power quality improvement by unified power quality conditioner based on CSC topology using synchronous reference frame theory.

    Science.gov (United States)

    Dharmalingam, Rajasekaran; Dash, Subhransu Sekhar; Senthilnathan, Karthikrajan; Mayilvaganan, Arun Bhaskar; Chinnamuthu, Subramani

    2014-01-01

    This paper deals with the performance of unified power quality conditioner (UPQC) based on current source converter (CSC) topology. UPQC is used to mitigate the power quality problems like harmonics and sag. The shunt and series active filter performs the simultaneous elimination of current and voltage problems. The power fed is linked through common DC link and maintains constant real power exchange. The DC link is connected through the reactor. The real power supply is given by the photovoltaic system for the compensation of power quality problems. The reference current and voltage generation for shunt and series converter is based on phase locked loop and synchronous reference frame theory. The proposed UPQC-CSC design has superior performance for mitigating the power quality problems.

  8. Power Quality Improvement by Unified Power Quality Conditioner Based on CSC Topology Using Synchronous Reference Frame Theory

    Science.gov (United States)

    Dharmalingam, Rajasekaran; Dash, Subhransu Sekhar; Senthilnathan, Karthikrajan; Mayilvaganan, Arun Bhaskar; Chinnamuthu, Subramani

    2014-01-01

    This paper deals with the performance of unified power quality conditioner (UPQC) based on current source converter (CSC) topology. UPQC is used to mitigate the power quality problems like harmonics and sag. The shunt and series active filter performs the simultaneous elimination of current and voltage problems. The power fed is linked through common DC link and maintains constant real power exchange. The DC link is connected through the reactor. The real power supply is given by the photovoltaic system for the compensation of power quality problems. The reference current and voltage generation for shunt and series converter is based on phase locked loop and synchronous reference frame theory. The proposed UPQC-CSC design has superior performance for mitigating the power quality problems. PMID:25013854

  9. Thermal homogeneity of plastication processes in single-screw extruders

    Science.gov (United States)

    Bu, L. X.; Agbessi, Y.; Béreaux, Y.; Charmeau, J.-Y.

    2018-05-01

    Single-screw plastication, used in extrusion and in injection moulding, is a major way of processing commodity thermoplastics. During the plastication phase, the polymeric material is melted by the combined effects of shear-induced self-heating (viscous dissipation) and heat conduction coming from the barrel. In injection moulding, a high level of reliability is usually achieved that makes this process ideally suited to mass market production. Nonetheless, process fluctuations still appear that make moulded part quality control an everyday issue. In this work, we used a combined modelling of plastication, throughput calculation and laminar dispersion, to investigate if, and how, thermal fluctuations could propagate along the screw length and affect the melt homogeneity at the end of the metering section. To do this, we used plastication models to relate changes in processing parameters to changes in the plastication length. Moreover, a simple model of throughput calculation is used to relate the screw geometry, the polymer rheology and the processing parameters to get a good estimate of the mass flow rate. Hence, we found that the typical residence time in a single screw is around one tenth of the thermal diffusion time scale. This residence time is too short for the dispersion coefficient to reach a steady state, but too long to be able to neglect radial thermal diffusion and resort to a purely convective solution. Therefore, a full diffusion/convection problem has to be solved with a base flow described by the classic pressure and drag velocity field. Preliminary results already show the major importance of the processing parameters in the breakthrough curve of an arbitrary temperature fluctuation at the end of the metering section of injection moulding screw. When the flow back-pressure is high, the temperature fluctuation is spread more evenly with time, whereas a pressure drop in the flow will results in a breakthrough curve which presents a larger peak of

  10. Clinical outcome and complications using a polyaxial locking plate in the treatment of displaced proximal humerus fractures. A reliable system?

    Science.gov (United States)

    Königshausen, M; Kübler, L; Godry, H; Citak, M; Schildhauer, T A; Seybold, D

    2012-02-01

    The surgical treatment of displaced proximal humeral fractures (ORIF) is a perpetual challenge to the surgeon. For this reason, the principle of polyaxiality was developed to provide an improved primary stability of the fracture through better anchorage of the screws, especially in osteoporotic bone. The aim of this study was to present clinical results with the polyaxial locking plate in the operative treatment of proximal humerus fractures in order to determine whether the technique of polyaxiality leads to better functional outcome and lower complication rates in comparison to monoaxial plates in the literature. Seventy-three patients with displaced proximal humeral fractures were treated surgically with the polyaxial locking Suture Plate™ (Arthrex(®)) between 03/2007 and 06/2009. Fifty-two of the patients (mean age, 69.9 ± 12.1) were included in a radiographical and clinical examination using the Constant score (CS) and the Disabilities of the Arm, Shoulder and Hand score (DASH). The follow-up examinations were on average 13.9 ± 4.5 months (10-27 months) after surgical treatment. The mean CS of the patients was 66.0 ± 13.7 points, the age- and gender-related CS was 90.9% ± 20.0% and the mean DASH score was 23.8 ± 19.8 points for the injured side. The patients with a nearly anatomical reduction of their fracture (n = 13) reached a significantly higher CS (75.1 ± 8.5; p = 0.004) and DASH-score (13.6 ± 11.6; p = 0.043) and none of these patients had a complication. The complications were identified in 12 (23.1%) cases, 5 of which involved loss of reduction. All of these 5 cases were lacking of initial medial column support and 4 of which were type C2.3 AO-Classification. The data show that the combination of angular stability with the possibility of variable polyaxial screw direction is a good concept for reduction and fixation of displaced proximal humeral fractures, but anatomical reduction and medial support remain important preconditions for a good

  11. Feasibility of translaminar screw placement in Korean population: morphometric analysis of cervical spine.

    Science.gov (United States)

    Ji, Gyu Yeul; Oh, Chang Hyun; Park, Sang Hyuk; Kurniawan, Ferry; Lee, Junho; Jeon, Jae Kyun; Shin, Dong Ah; Kim, Keung Nyun

    2015-01-01

    To analyze the feasibility of unilateral and bilateral translaminar screw placement in Koran population, and compare the acceptance rate using previously reported data in American population. The translaminar lengths, thickness, heights, and sagittal-diagonal measurements were performed. The feasibility analysis was performed using unilateral and bilateral 3.5 mm cervical screw placement on the CT scans within 0.5 mm of safety margin. We also performed radiographic analysis of the morphometric dimensions and the feasibility of unilateral and bilateral translaminar screw placement at C3-C7. Korean population had similar or significantly shorter translaminar lengths and thickness (lengths and thickness in C7 among males; lengths in C6-C7 and thickness in C4 among females) than American population, but had similar or significantly longer translaminar heights and sagittal-diagonal measurements (heights in C3-C7 and sagittal-diagonal measurements in C3-C6 among males; heights in C7 and sagittal-diagonal measurements in C3-C7 among females). Unilaterally, translaminar screw acceptance rates in C3-C7 were similar between Korean and American male population, but the rates in C4-C6 were significantly smaller between Korean and American female population. Bilaterally, translaminar screw acceptance rates in C3 and C5-C6 were significantly larger between Korean and American male population, but the rates in C3-C7 were similar between Korean and American female population. The feasibility of unilateral and bilateral translaminar screw placement is different depending on different ethnics. Subaxial cervical unilateral translaminar screw placement among Korean male population and bilateral placement at C4-C7 among Korean female population are more acceptable than American population.

  12. Wall locking and multiple nonlinear states of magnetic islands

    International Nuclear Information System (INIS)

    Persson, Mikael; Australian National Univ., Canberra, ACT

    1994-01-01

    The nonlinear evolution of magnetic islands is analysed in configurations with multiple resonant magnetic surfaces. The existence of multiple nonlinear steady states, is discussed. These are shown to be associated with states where the dynamics around the different rational surfaces are coupled or decoupled and in the presence of a wall of finite resistivity may correspond wall-locked or non-wall-locked magnetic islands. For the case of strong wall stabilization the locking is shown to consist of two different phases. During the first phase the locking of the plasma at the different rational surfaces occurs. Only when the outermost resonant magnetic surface has locked to the inner surfaces can the actual wall locking process take place. Consequently, wall locking, of a global mode, involving more than one rational surface, can be prevented by the decoupling of the resonant magnetic surfaces by plasma rotation. Possible implications on tokamak experiments are discussed. (author)

  13. Assessment of Different Metal Screw Joint Parameters by Using Multiple Criteria Analysis Methods

    Directory of Open Access Journals (Sweden)

    Audrius Čereška

    2018-05-01

    Full Text Available This study compares screw joints made of different materials, including screws of different diameters. For that purpose, 8, 10, 12, 14, 16 mm diameter steel screws and various parts made of aluminum (Al, steel (Stl, bronze (Brz, cast iron (CI, copper (Cu and brass (Br are considered. Multiple criteria decision making (MCDM methods such as evaluation based on distance from average solution (EDAS, simple additive weighting (SAW, technique for order of preference by similarity to ideal solution (TOPSIS and complex proportional assessment (COPRAS are utilized to assess reliability of screw joints also considering cost issues. The entropy, criterion impact loss (CILOS and integrated determination of objective criteria weights (IDOCRIW methods are utilized to assess weights of decision criteria and find the best design alternative. Numerical results confirm the validity of the proposed approach.

  14. Analysis of Modeling Parameters on Threaded Screws.

    Energy Technology Data Exchange (ETDEWEB)

    Vigil, Miquela S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brake, Matthew Robert [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Vangoethem, Douglas [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-06-01

    Assembled mechanical systems often contain a large number of bolted connections. These bolted connections (joints) are integral aspects of the load path for structural dynamics, and, consequently, are paramount for calculating a structure's stiffness and energy dissipation prop- erties. However, analysts have not found the optimal method to model appropriately these bolted joints. The complexity of the screw geometry cause issues when generating a mesh of the model. This paper will explore different approaches to model a screw-substrate connec- tion. Model parameters such as mesh continuity, node alignment, wedge angles, and thread to body element size ratios are examined. The results of this study will give analysts a better understanding of the influences of these parameters and will aide in finding the optimal method to model bolted connections.

  15. No Snowball on Habitable Tidally Locked Planets

    Energy Technology Data Exchange (ETDEWEB)

    Checlair, Jade; Abbot, Dorian S. [Department of the Geophysical Sciences, University of Chicago, 5734 South Ellis Avenue, Chicago, IL 60637 (United States); Menou, Kristen, E-mail: jadecheclair@uchicago.edu [Centre for Planetary Sciences, Department of Physical and Environmental Sciences, University of Toronto at Scarborough, Toronto, ON M1C 1A4 (Canada)

    2017-08-20

    The TRAPPIST-1, Proxima Centauri, and LHS 1140 systems are the most exciting prospects for future follow-up observations of potentially inhabited planets. All of the planets orbit nearby M-stars and are likely tidally locked in 1:1 spin–orbit states, which motivates the consideration of the effects that tidal locking might have on planetary habitability. On Earth, periods of global glaciation (snowballs) may have been essential for habitability and remote signs of life (biosignatures) because they are correlated with increases in the complexity of life and in the atmospheric oxygen concentration. In this paper, we investigate the snowball bifurcation (sudden onset of global glaciation) on tidally locked planets using both an energy balance model and an intermediate-complexity global climate model. We show that tidally locked planets are unlikely to exhibit a snowball bifurcation as a direct result of the spatial pattern of insolation they receive. Instead, they will smoothly transition from partial to complete ice coverage and back. A major implication of this work is that tidally locked planets with an active carbon cycle should not be found in a snowball state. Moreover, this work implies that tidally locked planets near the outer edge of the habitable zone with low CO{sub 2} outgassing fluxes will equilibrate with a small unglaciated substellar region rather than cycling between warm and snowball states. More work is needed to determine how the lack of a snowball bifurcation might affect the development of life on a tidally locked planet.

  16. Computer simulation of migration atomic mechanism and substitutional impurity interaction with screw dislocation core in bcc lattice

    International Nuclear Information System (INIS)

    Klyavin, O.V.; Likhodedov, N.P.; Orlov, A.N.

    1986-01-01

    Distribution and migration of substitutional impurity atoms (He and C) in the screw dislocation core of the 1/2 type is studied in α-Fe. The atomic mechanism of impurity atom diffusion over screw dislocation core, consisting in the fact that impurity migration proceeds in a screw trajectory, is discovered and analyzed. It is shown that tubular He diffusion over screw dislocation may proceed at T <= 300 K

  17. Short locking time and low jitter phase-locked loop based on slope charge pump control

    International Nuclear Information System (INIS)

    Guo Zhongjie; Liu Youbao; Wu Longsheng; Wang Xihu; Tang Wei

    2010-01-01

    A novel structure of a phase-locked loop (PLL) characterized by a short locking time and low jitter is presented, which is realized by generating a linear slope charge pump current dependent on monitoring the output of the phase frequency detector (PFD) to implement adaptive bandwidth control. This improved PLL is created by utilizing a fast start-up circuit and a slope current control on a conventional charge pump PLL. First, the fast start-up circuit is enabled to achieve fast pre-charging to the loop filter. Then, when the output pulse of the PFD is larger than a minimum value, the charge pump current is increased linearly by the slope current control to ensure a shorter locking time and a lower jitter. Additionally, temperature variation is attenuated with the temperature compensation in the charge pump current design. The proposed PLL has been fabricated in a kind of DSP chip based on a 0.35 μm CMOS process. Comparing the characteristics with the classical PLL, the proposed PLL shows that it can reduce the locking time by 60% with a low peak-to-peak jitter of 0.3% at a wide operation temperature range. (semiconductor integrated circuits)

  18. Clinical results and functional outcomes after direct intralaminar screw repair of spondylolysis.

    Science.gov (United States)

    Menga, Emmanuel N; Kebaish, Khaled M; Jain, Amit; Carrino, John A; Sponseller, Paul D

    2014-01-01

    Prospective analysis. Our objective was to analyze clinical and functional results of patients with spondylolysis treated via direct intralaminar screw fixation and autograft, a minimally invasive and motion-preserving surgery. Spondylolysis is usually treated nonoperatively; multiple surgical techniques are available when nonoperative measures fail. No studies evaluate the clinical and functional outcomes and their correlation with pars defect size and disc morphology on magnetic resonance imaging. We reviewed patients with spondylolysis treated with intralaminar screw fixation and bone grafting from 2000 through 2010. Of the 31 patients (mean age, 16 yr; range, 10-37 yr), 25 (81%) were competitive athletes. Preoperative computed tomographic scans were used to measure the pars defect size, and preoperative magnetic resonance images were graded using Pfirrmann classification for correlation with postoperative outcomes. Student t test was used for analysis (significance, P spondylolysis repair for persistent pain starting 18 months after intralaminar screw fixation, 2 patients sustained unilateral intralaminar screw fractures at L5, and 1 patient required irrigation and debridement for a superficial postoperative infection. There was no correlation among preoperative magnetic resonance imaging disc morphology, defect size on computed tomography, patient age, and clinical outcomes. Direct repair of spondylolysis with intralaminar screws offers a low profile, reliable treatment with good functional outcome and a low complication rate in active patients. 4.

  19. Arm locking with Doppler estimation errors

    Energy Technology Data Exchange (ETDEWEB)

    Yu Yinan; Wand, Vinzenz; Mitryk, Shawn; Mueller, Guido, E-mail: yinan@phys.ufl.ed [Department of Physics, University of Florida, Gainesville, FL 32611 (United States)

    2010-05-01

    At the University of Florida we developed the University of Florida LISA Interferometer Simulator (UFLIS) in order to study LISA interferometry with hardware in the loop at a system level. One of the proposed laser frequency stabilization techniques in LISA is arm locking. Arm locking uses an adequately filtered linear combination of the LISA arm signals as a frequency reference. We will report about experiments in which we demonstrated arm locking using UFLIS. During these experiments we also discovered a problem associated with the Doppler shift of the return beam. The initial arm locking publications assumed that this Doppler shift can perfectly be subtracted inside the phasemeter or adds an insignificant offset to the sensor signal. However, the remaining Doppler knowledge error will cause a constant change in the laser frequency if unaccounted for. Several ways to circumvent this problem have been identified. We performed detailed simulations and started preliminary experiments to verify the performance of the proposed new controller designs.

  20. Axial loading screw fixation for chevron type osteotomies of the distal first metatarsal: a retrospective outcomes analysis.

    Science.gov (United States)

    Murphy, Ryan M; Fallat, Lawrence M; Kish, John P

    2014-01-01

    The distal chevron osteotomy is a widely accepted technique for the treatment of hallux abductovalgus deformity. Although the osteotomy is considered to be stable, displacements of the capital fragment has been described. We propose a new method for fixation of the osteotomy involving the axial loading screw (ALS) used in addition to single screw fixation. We believe this method will provide a more mechanically stable construct. We reviewed the charts of 46 patients in whom 52 feet underwent a distal chevron osteotomy that was fixated with either 1 screw or 2 screws that included the ALS. We hypothesized that the ALS group would have fewer displacements and would heal more quickly than the single screw fixation group. We found that the group with ALS fixation had healed at a mean of 6.5 weeks and that the group with single screw fixation had healed at 9.53 weeks (p = .001). Also, 8 cases occurred of displacement of the capital fragment in the single screw, control group compared with 2 cases of displacement in the ALS group. However, this finding was not statistically significant. The addition of the ALS to single screw fixation allowed the patients to heal approximately 3 weeks earlier than single screw fixation alone. The ALS is a fixation option for the surgeon to consider when osseous correction of hallux abducto valgus is performed. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Biomechanical Analysis of Suture Anchor vs Tenodesis Screw for FHL Transfer.

    Science.gov (United States)

    Drakos, Mark C; Gott, Michael; Karnovsky, Sydney C; Murphy, Conor I; DeSandis, Bridget A; Chinitz, Noah; Grande, Daniel; Chahine, Nadeen

    2017-07-01

    Chronic Achilles injury is often treated with flexor hallucis longus (FHL) tendon transfer to the calcaneus using 1 or 2 incisions. A single incision avoids the risks of extended dissections yet yields smaller grafts, which may limit fixation options. We investigated the required length of FHL autograft and biomechanical profiles for suture anchor and biotenodesis screw fixation. Single-incision FHL transfer with suture anchor or biotenodesis screw fixation to the calcaneus was performed on 20 fresh cadaveric specimens. Specimens were cyclically loaded until maximal load to failure. Length of FHL tendon harvest, ultimate load, stiffness, and mode of failure were recorded. Tendon harvest length needed for suture anchor fixation was 16.8 ± 2.1 mm vs 29.6 ± 2.4 mm for biotenodesis screw ( P = .002). Ultimate load to failure was not significantly different between groups. A significant inverse correlation existed between failure load and donor age when all specimens were pooled (ρ = -0.49, P Anchor failure occurred mostly by suture breakage (n = 8). Adequate FHL tendon length could be harvested through a single posterior incision for fixation to the calcaneus with either fixation option, but suture anchor required significantly less graft length. Stiffness, fixation strength, and load to failure were comparable between groups. An inverse correlation existed between failure load and donor age. Younger specimens with screw fixation demonstrated significantly greater failure loads. Adequate harvest length for FHL transfer could be achieved with a single posterior incision. There was no difference in strength of fixation between suture anchor and biotenodesis screw.

  2. Clinical Outcomes of Posterior C1 and C2 Screw-Rod Fixation for Atlantoaxial Instability.

    Science.gov (United States)

    Işik, Hasan Serdar; Sandal, Evren; Çağli, Sedat

    2017-06-14

    In this study, we aimed at sharing our experiences and contributing to the literature by making a retrospective analysis of the patients we operated with screw-rod system for atlantoaxial instability in our clinic. Archive files of adult patients, who were operated for posterior C1-C2 stabilization with screw and rod in our clinic between January 2006 and January 2016, were analyzed. 28 patients, who had pre and post-operative images, follow-up forms and who were followed for at least one year, were analyzed. Preoperative clinical and radiological records, preoperative observations, postoperative complications, and clinical responses were evaluated. The average age of 28 patients (F:13 M:19) was 44.7 (21-73). Fixation was performed with C1-C2 screw-rod system on the basis of the following diagnoses; type 2 odontoid fracture (16), basilar invagination (5), C1-C2 instability (5), and atlantoaxial subluxation secondary to rheumatoid arthritis (2). Lateral mass screws were inserted at C1 segment. C2 screws inserted were bilateral pedicle in 12 cases, bilateral pars in 4, bilateral laminar in 8 and one side pars, one side laminar in 4 cases. There was no screw malposition. Neither implant failure nor recurrent instability was observed during follow-up. Significant clinical improvement was reported according to the assessments done with JOA and VAS scores. C1-C2 screw fixation is regarded as a more successful and safe method than other fixation methods in surgical treatment of atlantoaxial instability considering complications, success in reduction, fusion and fixation strength. C2 laminar screw technique is as successful as the other alternatives in fixation and fusion.

  3. Use of a life-size three-dimensional-printed spine model for pedicle screw instrumentation training.

    Science.gov (United States)

    Park, Hyun Jin; Wang, Chenyu; Choi, Kyung Ho; Kim, Hyong Nyun

    2018-04-16

    Training beginners of the pedicle screw instrumentation technique in the operating room is limited because of issues related to patient safety and surgical efficiency. Three-dimensional (3D) printing enables training or simulation surgery on a real-size replica of deformed spine, which is difficult to perform in the usual cadaver or surrogate plastic models. The purpose of this study was to evaluate the educational effect of using a real-size 3D-printed spine model for training beginners of the free-hand pedicle screw instrumentation technique. We asked whether the use of a 3D spine model can improve (1) screw instrumentation accuracy and (2) length of procedure. Twenty life-size 3D-printed lumbar spine models were made from 10 volunteers (two models for each volunteer). Two novice surgeons who had no experience of free-hand pedicle screw instrumentation technique were instructed by an experienced surgeon, and each surgeon inserted 10 pedicle screws for each lumbar spine model. Computed tomography scans of the spine models were obtained to evaluate screw instrumentation accuracy. The length of time in completing the procedure was recorded. The results of the latter 10 spine models were compared with those of the former 10 models to evaluate learning effect. A total of 37/200 screws (18.5%) perforated the pedicle cortex with a mean of 1.7 mm (range, 1.2-3.3 mm). However, the latter half of the models had significantly less violation than the former half (10/100 vs. 27/100, p 3D-printed spine model can be an excellent tool for training beginners of the free-hand pedicle screw instrumentation.

  4. Unconventional fixation Thoracolumbar fractures using round hole boneplates and transpedicular screws

    International Nuclear Information System (INIS)

    Behairy, Yaser M.

    2001-01-01

    In an attempt to contain the high cost of commercially available pediclescrew systems, several authors have used unconventional alternatives such aslocally made plates or dynamic compression plates (DCP) along with cancellousscrews for transpedicular fixation of the thoracolumbar spine. These plates,however, allow for a wide range of motion at the plate-screw interphase andthe construct does not provide stability in the sagittal plane. Round holebone plates, on the other hand, allow much less mobility at the plate-screwinterphase and the final construct offers better stability in the sagittalplane. Our objective was to determine the clinical, radiologic and functionalstatus of patients who underwent posterior fracture fixation using round holebone plates and cancellous screws and evaluate the construct's ability tomaintain reduction of the fracture. This was a postoperative follow-up ofpatients with fractures around the thoracolumbar junction fixed using roundhole bone plates and cancellous transpedicular screws. Round hole bone platesalong with 6.5 mm transpedicular cancellous screws were used for posteriorspinal instrumentation in neurologically intact patients with isolatedunstable fractures of the last thoracic or first lumbar vertebra. Seventeenpatients were included in this study. There mean follow-up was 10 months(range 5 to 12). All had evidence of fusion at a mean of 5 months (range 4 to7). No patients had breakage or loosening of the screws and none had breakageof the plate. The mean kyphosis angle at the fracture site was 34 degreepreoperatively, -4 degree in the immediate postoperative period, and 3 degreeon final follow-up radiographs. The percentage loss of anterior vertebralbody height was 51% in the immediate postoperative period and 16% on finalfollow-up radiographs. The use of round hole bone plates along with 6.5 mmcancellous screws inserted into the pedicles provides an angle-stableconstruct that allows for better stability in the sagittal plane

  5. [Polymethylmethacrylate augmentation of bone cement-injectable cannulated pedicle screws for the treatment of degenerative lumbar diseases with osteoporosis].

    Science.gov (United States)

    Sun, H L; Li, C D; Yang, Z C; Yi, X D; Liu, H; Lu, H L; Li, H; Wang, Y

    2016-12-18

    To describe the application of polymethylmethacrylate augmentation of bone cement-injectable cannulated pedicle screws for the treatment of degenerative lumbar diseases with osteoporosis. Observation group included 14 cases of degenerative lumbar diseases with osteoporosis received polymethylmethacrylate augmentation of bone cement-injectable cannulated pedicle screws from November 2014 to July 2015, control group included 12 cases of degenerative lumbar diseases with osteoporosis received polymethylmethacrylate augmentation with traditional pedicle screws.The operation time, blood loss, number of pedicle screws and number of augmented pedicle screws in the two groups were compared. The bone cement leakage and pulmonary bone cement embolism in the two groups were also compared. The fusion rate and pedicle screws loosening by lumbar X ray and dynamic X ray were evaluated. The clinical results were assessed by visual analog scale (VAS) of pain on lumbar and lower limbers, lumbar Japanese Orthopaedic Association scores (JOA), Prolo functional scores and Oswestry disability (ODI) scores. Differences of operation time and blood loss in the two groups were not statistically significant. The average number of pedicle screws was 9.9±4.7 and the average number of augmented pedicle screws was 5.9±2.6 in observation group while the average number of pedicle screws was 7.1±2.8 and the average number of augmented pedicle screws was 3.0±1.9 in control group. The ratio of augmented pedicle screws was higher in observation group than in control group (0.69±0.30 vs.0.47±0.30,Pdegenerative lumbar diseases with osteoporosis was effective, with simple working processes and lower risk of bone cement leakage. The short-term clinical result was good.

  6. Bone properties of the humeral head and resistance to screw cutout

    DEFF Research Database (Denmark)

    Frich, L. H.; Jensen, N. C.

    2014-01-01

    Surgical treatment of fractures involving the proximal humeral head is hampered by complications. Screw cutout is the major pitfall seen in connection with rigid plating. We have exploited a bony explanation for this phenomenon. Materials and Methods: We examined the convex surface of the humeral...... sectioning technique. Results: The bone strength and bone density correlated well and revealed large regional variations across the humeral head. Bone strength and stiffness of the trabecular bone came to a maximum in the most medial anterior and central parts of the humeral head, where strong textural...... screw directions will predictably place screws in areas of the humeral head comprising low density and low strength cancellous bone. New concepts of plates and plating techniques for the surgical treatment of complex fractures of the proximal humerus should take bone distribution, strength...

  7. Investigation on Locking and Pulling Modes in Analog Frequency Dividers

    Directory of Open Access Journals (Sweden)

    Antonio Buonomo

    2013-01-01

    Full Text Available We compare the main analytical results available to estimate the locking range, which is the key figure-of-merit of LC frequency dividers based on the injection locking phenomenon. Starting from the classical result by Adler concerning injection-locked oscillators, we elucidate the merits and the shortcomings of the different approaches to study injection-locked frequency dividers, with particular emphasis on divider-by-2. In particular, we show the potential of a perturbation approach which enables a more complete analysis of frequency dividers, making it possible to calculate not only the amplitude and the phase of the locked oscillation, but also the region where it exists and is stable, which defines the locking region. Finally, we analyze the dynamical behaviour of the dividers in the vicinity of the boundary of the locking region, showing that there exists a border region where the occurrence of the locking or the pulling operation mode is possible, depending on the initial conditions of the system.

  8. Theoretical prediction of pullout strengths for dental and orthopaedic screws with conical profile and buttress threads.

    Science.gov (United States)

    Shih, Kao-Shang; Hou, Sheng-Mou; Lin, Shang-Chih

    2017-12-01

    The pullout strength of a screw is an indicator of how secure bone fragments are being held in place. Such bone-purchasing ability is sensitive to bone quality, thread design, and the pilot hole, and is often evaluated by experimental and numerical methods. Historically, there are some mathematical formulae to simulate the screw withdrawal from the synthetic bone. There are great variations in screw specifications. However, extensive investigation of the correlation between experimental and analytical results has not been reported in literature. Referring to the literature formulae, this study aims to evaluate the differences in the calculated pullout strengths. The pullout tests of the surgical screws are measured and the sawbone is used as the testing block. The absolute errors and correlation coefficients of the experimental and analytical results are calculated as the comparison baselines of the formulae. The absolute error of the dental, traumatic, and spinal groups are 21.7%, 95.5%, and 37.0%, respectively. For the screws with a conical profile and/or tiny threads, the calculated and measured results are not well correlated. The formulae are not accurate indicators of the pullout strengths of the screws where the design parameters are slightly varied. However, the experimental and numerical results are highly correlated for the cylindrical screws. The pullout strength of a conical screw is higher than that of its counterpart, but all formulae consistently predict the opposite results. In general, the bony purchase of the buttress threads is securer than that of the symmetric thread. An absolute error of up to 51.4% indicates the theoretical results cannot predict the actual value of the pullout strength. Only thread diameter, pitch, and depth are considered in the investigated formulae. The thread profile and shape should be formulated to modify the slippage mechanism at the bone-screw interfaces and simulate the strength change in the squeezed bones

  9. Potential risks of using cement-augmented screws for spinal fusion in patients with low bone quality.

    Science.gov (United States)

    Martín-Fernández, M; López-Herradón, A; Piñera, A R; Tomé-Bermejo, F; Duart, J M; Vlad, M D; Rodríguez-Arguisjuela, M G; Alvarez-Galovich, L

    2017-08-01

    Dramatic increases in the average life expectancy have led to increases in the variety of degenerative changes and deformities observed in the aging spine. The elderly population can present challenges for spine surgeons, not only because of increased comorbidities, but also because of the quality of their bones. Pedicle screws are the implants used most commonly in spinal surgery for fixation, but their efficacy depends directly on bone quality. Although polymethyl methacrylate (PMMA)-augmented screws represent an alternative for patients with osteoporotic vertebrae, their use has raised some concerns because of the possible association between cement leakages (CLs) and other morbidities. To analyze potential complications related to the use of cement-augmented screws for spinal fusion and to investigate the effectiveness of using these screws in the treatment of patients with low bone quality. A retrospective single-center study. This study included 313 consecutive patients who underwent spinal fusion using a total of 1,780 cement-augmented screws. We analyzed potential complications related to the use of cement-augmented screws, including CL, vascular injury, infection, screw extraction problems, revision surgery, and instrument failure. There are no financial conflicts of interest to report. A total of 1,043 vertebrae were instrumented. Cement leakage was observed in 650 vertebrae (62.3%). There were no major clinical complications related to CL, but two patients (0.6%) had radicular pain related to CL at the S1 foramina. Of the 13 patients (4.1%) who developed deep infections requiring surgical debridement, two with chronic infections had possible spondylitis that required instrument removal. All patients responded well to antibiotic therapy. Revision surgery was performed in 56 patients (17.9%), most of whom had long construction. A total of 180 screws were removed as a result of revision. There were no problems with screw extraction. These results

  10. Release of metal in vivo from stressed and nonstressed maxillofacial fracture plates and screws.

    Science.gov (United States)

    Matthew, I R; Frame, J W

    2000-07-01

    To analyze the release of metal into the adjacent tissues from stressed and nonstressed titanium and stainless steel miniplates and screws. Two miniplates were inserted into the cranial vaults of 12 beagle dogs while they were under general endotracheal anesthesia. One miniplate was shaped to fit the curvature of the skull (control). Another miniplate, made of the same material, was bent in a curve until the midpoint was raised 3 mm above the ends. Screws were inserted and tightened until the plate conformed to the skull curvature, creating stresses in the system. Four animals (2 each, having titanium or stainless steel plates and screws) were killed after 4, 12, and 24 weeks. Metallosis of adjacent soft tissues was assessed qualitatively. Miniplates and screws were removed, and adjacent soft tissue and bone was excised. Titanium, iron, chromium, nickel, and aluminum levels were assayed by ultraviolet/visible light and atomic absorption spectrophotometry. Nonparametric statistical methods were used for data analysis. There was no clear relationship between pigmentation of soft tissue adjacent to the miniplates and screws and the concentrations of metal present. The data did not demonstrate any consistent differences in the concentrations of metallic elements next to stressed and nonstressed (control) miniplates and screws of either material. Stresses arising through poor contouring of miniplates do not appear to influence the extent of release of metal into the adjacent tissues.

  11. Cortical bone trajectory screw fixation versus traditional pedicle screw fixation for 2-level posterior lumbar interbody fusion: comparison of surgical outcomes for 2-level degenerative lumbar spondylolisthesis.

    Science.gov (United States)

    Sakaura, Hironobu; Miwa, Toshitada; Yamashita, Tomoya; Kuroda, Yusuke; Ohwada, Tetsuo

    2018-01-01

    OBJECTIVE The cortical bone trajectory (CBT) screw technique is a new nontraditional pedicle screw (PS) insertion method. However, the biomechanical behavior of multilevel CBT screw/rod fixation remains unclear, and surgical outcomes in patients after 2-level posterior lumbar interbody fusion (PLIF) using CBT screw fixation have not been reported. Thus, the purposes of this study were to examine the clinical and radiological outcomes after 2-level PLIF using CBT screw fixation for 2-level degenerative lumbar spondylolisthesis (DS) and to compare these outcomes with those after 2-level PLIF using traditional PS fixation. METHODS The study included 22 consecutively treated patients who underwent 2-level PLIF with CBT screw fixation for 2-level DS (CBT group, mean follow-up 39 months) and a historical control group of 20 consecutively treated patients who underwent 2-level PLIF using traditional PS fixation for 2-level DS (PS group, mean follow-up 35 months). Clinical symptoms were evaluated using the Japanese Orthopaedic Association (JOA) scoring system. Bony union was assessed by dynamic plain radiographs and CT images. Surgery-related complications, including symptomatic adjacent-segment disease (ASD), were examined. RESULTS The mean operative duration and intraoperative blood loss were 192 minutes and 495 ml in the CBT group and 218 minutes and 612 ml in the PS group, respectively (p 0.05, respectively). The mean JOA score improved significantly from 12.3 points before surgery to 21.1 points (mean recovery rate 54.4%) at the latest follow-up in the CBT group and from 12.8 points before surgery to 20.4 points (mean recovery rate 51.8%) at the latest follow-up in the PS group (p > 0.05). Solid bony union was achieved at 90.9% of segments in the CBT group and 95.0% of segments in the PS group (p > 0.05). Symptomatic ASD developed in 2 patients in the CBT group (9.1%) and 4 patients in the PS group (20.0%, p > 0.05). CONCLUSIONS Two-level PLIF with CBT screw fixation

  12. Performance Monitoring System: Summary of Lock Statistics. Revision 1.

    Science.gov (United States)

    1985-12-01

    2751 84 4057 4141 526 798 18 1342 5727 19 5523 3996 4587 8583 1056 1630 35 2721 6536LOCK A DAMI 2 AUXILIARY I Ins NO DATA RECORDD FOR THIS LOCK- " LOCK I...TOTAL (KTOMS) ’ - (AVt OPNP ETC) ’’ ,q [ " ARKANSAS RIVER "" FORRELL LOCK IP 7A/3TRC 9/N83 UPBOUID STATISTICS ISO 53 42 M6 553 356 909 221 41 21 M8

  13. Precision insertion of percutaneous sacroiliac screws using a novel augmented reality-based navigation system: a pilot study.

    Science.gov (United States)

    Wang, Huixiang; Wang, Fang; Leong, Anthony Peng Yew; Xu, Lu; Chen, Xiaojun; Wang, Qiugen

    2016-09-01

    Augmented reality (AR) enables superimposition of virtual images onto the real world. The aim of this study is to present a novel AR-based navigation system for sacroiliac screw insertion and to evaluate its feasibility and accuracy in cadaveric experiments. Six cadavers with intact pelvises were employed in our study. They were CT scanned and the pelvis and vessels were segmented into 3D models. The ideal trajectory of the sacroiliac screw was planned and represented visually as a cylinder. For the intervention, the head mounted display created a real-time AR environment by superimposing the virtual 3D models onto the surgeon's field of view. The screws were drilled into the pelvis as guided by the trajectory represented by the cylinder. Following the intervention, a repeat CT scan was performed to evaluate the accuracy of the system, by assessing the screw positions and the deviations between the planned trajectories and inserted screws. Post-operative CT images showed that all 12 screws were correctly placed with no perforation. The mean deviation between the planned trajectories and the inserted screws was 2.7 ± 1.2 mm at the bony entry point, 3.7 ± 1.1 mm at the screw tip, and the mean angular deviation between the two trajectories was 2.9° ± 1.1°. The mean deviation at the nerve root tunnels region on the sagittal plane was 3.6 ± 1.0 mm. This study suggests an intuitive approach for guiding screw placement by way of AR-based navigation. This approach was feasible and accurate. It may serve as a valuable tool for assisting percutaneous sacroiliac screw insertion in live surgery.

  14. Key-lock colloids in a nematic liquid crystal.

    Science.gov (United States)

    Silvestre, Nuno M; Tasinkevych, M

    2017-01-01

    The Landau-de Gennes free energy is used to study theoretically the effective interaction of spherical "key" and anisotropic "lock" colloidal particles. We assume identical anchoring properties of the surfaces of the key and of the lock particles, and we consider planar degenerate and perpendicular anchoring conditions separately. The lock particle is modeled as a spherical particle with a spherical dimple. When such a particle is introduced into a nematic liquid crystal, it orients its dimple at an oblique angle θ_{eq} with respect to the far field director n_{∞}. This angle depends on the depth of the dimple. Minimization results show that the free energy of a pair of key and lock particles exhibits a global minimum for the configuration when the key particle is facing the dimple of the lock colloidal particle. The preferred orientation ϕ_{eq} of the key-lock composite doublet relative to n_{∞} is robust against thermal fluctuations. The preferred orientation θ_{eq}^{(2)} of the dimple particle in the doublet is different from the isolated situation. This is related to the "direct" interaction of defects accompanying the key particle with the edge of the dimple. We propose that this nematic-amplified key-lock interaction can play an important role in self-organization and clustering of mixtures of colloidal particles with dimple colloids present.

  15. Optimization and Numerical Simulation of Outlet of Twin Screw Extruder

    Directory of Open Access Journals (Sweden)

    Zhang Yuan

    2018-01-01

    Full Text Available In view of the unreasonable design of non-intermeshing counter-rotating twin screw extruder die, the problem of productivity reduction was discussed. Firstly, the mathematical model of extruder productivity was established. The extruder die model was improved. Secondly, the force analysis of twin screw extruder physical model was carried out. Meanwhile, A combination of mechanical analysis and numerical simulation was adopted. The velocity field, pressure field and viscosity field were calculated by Mini-Element interpolation method, linear interpolation method and Picard iterative convergence method respectively. The influence of die model on the quantity of each field before and after improvement was analyzed. The results show that the improved model had increased the rheological parameters of the flow field, the leakage and reverse flow decreased. Through post-processing calculation, the productivity of the third dies extruder was 10% higher than before. The research results provide a theoretical basis for the design and optimization of die model of non intermeshing counter-rotating twin screw extruder.

  16. Recurrent Laryngeal Edema Imitating Angioedema Caused by Dislocated Screw after Anterior Spine Surgery

    Directory of Open Access Journals (Sweden)

    Piotr Wójtowicz

    2015-01-01

    Full Text Available The anterior cervical spine surgery is a common procedure to stabilize vertebrae damaged by various diseases. The plates and screws are usually used in the spine fixation. This kind of instrumentation may detach from the bones which is a rare but well-known complication. A 77-year-old male presented to the otorhinolaryngology department with throat pain, choking, and dysphagia. At first the angioedema was diagnosed and he was treated conservatively. The endoscopy revealed laryngeal edema, being more defined on the right side with right vocal fold paresis. CT scans showed the stabilizing plate with two screws attached tightly and the back-out of the third screw toward soft tissue of the neck. In the meantime, his condition deteriorated and he needed tracheotomy. In few days the surgical removal of the dislocated screw was performed successfully. Although two-month follow-up reported no obstruction of the larynx, the vocal folds paresis with gradual functional improvement was observed. Long-term complication of anterior spine surgery sometimes may suggest laryngeal angioedema at first. If the conservative treatment is ineffective and there is a history of anterior spine surgery, the clinicians should consider the displacement of the plate or screws in differential diagnosis.

  17. Conceptual framework for model-based analysis of residence time distribution in twin-screw granulation

    DEFF Research Database (Denmark)

    Kumar, Ashish; Vercruysse, Jurgen; Vanhoorne, Valerie

    2015-01-01

    Twin-screw granulation is a promising continuous alternative for traditional batchwise wet granulation processes. The twin-screw granulator (TSG) screws consist of transport and kneading element modules. Therefore, the granulation to a large extent is governed by the residence time distribution...... within each module where different granulation rate processes dominate over others. Currently, experimental data is used to determine the residence time distributions. In this study, a conceptual model based on classical chemical engineering methods is proposed to better understand and simulate...... the residence time distribution in a TSG. The experimental data were compared with the proposed most suitable conceptual model to estimate the parameters of the model and to analyse and predict the effects of changes in number of kneading discs and their stagger angle, screw speed and powder feed rate...

  18. Monolithic Hybrid and Passive Mode-Locked 40GHz Quantum Dot Laser Diodes

    DEFF Research Database (Denmark)

    Thompson, M. G.; Larsson, David; Rae, A. R.

    2006-01-01

    For the first time hybrid and passive mode-locking jitter performance is investigated in 40GHz quantum-dot mode-locked lasers. Record low passive mode-locking jitter of 219fs is presented, along with promising hybrid mode-locking results of 124fs.......For the first time hybrid and passive mode-locking jitter performance is investigated in 40GHz quantum-dot mode-locked lasers. Record low passive mode-locking jitter of 219fs is presented, along with promising hybrid mode-locking results of 124fs....

  19. A comparitive clinical study between self tapping and drill free screws as a source of rigid orthodontic anchorage.

    Science.gov (United States)

    Gupta, Nishant; Kotrashetti, S M; Naik, Vijay

    2012-03-01

    Self-tapping miniscrews are commonly being used as a temporary anchorage device for orthodontic purpose. A prerequisite for the insertion of these screws is the preparation of a pilot hole, which is time consuming and may result in damage to nerves, tooth root, drill bit breakage and thermal necrosis of bone. On the other hand the design of drill-free screws enables them to be inserted without drilling. The aim of this prospective study was to compare the stability and clinical response of the soft tissue around the self tapping and drill free screws when used for orthodontic anchorage for en mass retraction of maxillary anterior teeth. The study sample consisted of 20 patients requiring retraction of maxillary anterior teeth. The screws were placed in the alveolar bone between maxillary 2nd premolar and 1st molar bilaterally at the junction of attached gingiva and moveable mucosa. Pilot hole was drilled on the side which was selected for insertion of the self tapping screw under copious irrigation, after which it was inserted. Drill free screw was inserted on the contralateral side without predrilling. All screws were immediately loaded with 150-200 gm of retraction force. Patients were recalled for regular follow up for a period of 6 months. If the screws became mobile or showed any signs of inflammation during the course of the study, they were considered to be a failure. After a period of 6 months an overall success rate of 77.5% was noted. Four self tapping and five drill-free screws failed during the study. There was no statistically significant difference between the two types of screws with respect to success/failure. Mobility was found to be the major cause for the failure. Both self-tapping and the drill-free screws are effective anchorage units. But the latter have an edge over the conventional self-tapping screws because of decrease in operative time, little bone debris, less thermal damage, lower morbidity, and minimal patient discomfort as

  20. Locks at reactor safety containments of nuclear power plants

    International Nuclear Information System (INIS)

    1978-12-01

    The rule is to be applied for material access locks. A material access lock as defined by this rule is a pressure resistant and technically gas-tight hollow body that is connected with the containment and has got two doors, the inner door of which connects the lock chamber with the interior of the containment and the outer door connects the lock chamber with the outside. It serves exclusively for transferring material or objects. (orig./HP) [de

  1. Root contact with maxillomandibular fixation screws in orthognathic surgery: incidence and consequences.

    Science.gov (United States)

    Camargo, I B; Van Sickels, J E; Laureano Filho, J R; Cunningham, L L

    2016-08-01

    The use of maxillomandibular fixation (MMF) screws in orthognathic surgery has become common in recent years. The risk of injury to adjacent roots with their placement in this population has not been studied extensively. The aim of this study was to review the incidence and consequences of root contact/injury in patients undergoing orthognathic surgery. A retrospective analysis of the treatment and radiographic records of patients who underwent orthognathic surgery between January 2013 and September 2014 at a university in Kentucky, USA was performed. The mean number of screws used was correlated to the mean number of roots affected using Spearman's test, set to a level of significance of 5%. Of 125 patients who underwent orthognathic surgery, 15 (12%) had evidence of root contact. Subsequent radiographs showed resolution of the bone defects. There was no clinical evidence of pulpal necrosis or pain during follow-up. The average number of screws used was 3.14±0.35 per patient, with an average of 0.17±0.52 root contacts per patient. There was no correlation between the number of screws used and the number of roots injured (P=0.279). Based on these results, MMF screws can safely be used to establish interim fixation during orthognathic surgery. Caution should be taken during placement to avoid direct injury to the roots of teeth. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. Acromioclavicular Joint Fixation Using an Acroplate Combined With a Coracoclavicular Screw

    Science.gov (United States)

    Tavakoli Darestani, Reza; Ghaffari, Arash; Hosseinpour, Mehrdad

    2013-01-01

    Background Appropriate treatment of acromioclavicular joint dislocation is controversial. Acroplate fixation is one of the most common treatment methods of acromioclavicular joint (ACJ) dislocation. Based on the risk of re-dislocation after Acroplate fixation, we assumed that combined fixation with an Acroplate and a coracoclavicular screw helps improve the outcome. Objectives The main purpose of the current study was to compare the outcome of ACJ dislocation treated with an Acroplate alone and in combination with coracoclavicular screw. Patients and Methods This study was carried out on 40 patients with ACJ dislocation types III to VI who were divided randomly into two equal groups: Acroplate group (P) and Acroplate in combination with coracoclavicular screw group (P + S). The screws were extracted 3-6 months postoperatively. The patients were followed for 1 year and Imatani’s score was calculated. Finally, the data were compared between the groups. Results The mean Imatani’s score was significantly higher in P + S group (83.4 ± 14.1) than P group (81.2 ± 10.3) (P < 0.001). The mean duration of surgery was the same in the two groups (59.8 ± 9.4 minutes in group P V.s 64.3 ± 10.9 minutes in group P + S; P = 0.169). There were no cases of re-dislocation, degenerative changes and ossification and all patients returned to their previous jobs or sporting activities. Conclusions Using a coracoclavicular screw combined with an Acroplate can improve the patients’ function after ACJ disruption without any significant increase in surgical duration. Authors recommend this technique in the fixation of ACJ dislocation. PMID:24396788

  3. ADOLESCENT IDIOPATHIC SCOLIOSIS: EVALUATION ON THE EFFECT OF SCREW DENSITY IN THE CORRECTION

    Directory of Open Access Journals (Sweden)

    Enguer Beraldo Garcia

    2016-03-01

    Full Text Available ABSTRACT Objective: The objective was to investigate implant density or the number of screws correlated with the correction of the main curve in patients undergoing surgery for adolescent idiopathic scoliosis (AIS. Methods: We evaluated 112 medical records: 33 patients with screw density of up to 50%, and 79 patients with a density of 100%; all patients underwent surgical correction by posterior approach with transpedicular fixation. Results: In the group of patients with screw density of up to 50% the residual Cobb median was 10°; in the group with 100% density, the median was 7°. Conclusion: Biostatistical analysis showed that the group with up to 50% of screw density presented correction rate of 82.1% and the group with 100% density had correction of about 86.8%. It is therefore concluded that the difference is statistically significant in favor of the fixation with 100% density (p =0.010.

  4. Parameters Affecting the Extraction Process of Jatropha Curcas Oil Using a Single Screw Extruder

    OpenAIRE

    Siregar, Ali Nurrakhmad; Ghani, Jaharah A; Che Haron, Che Hassan; Rizal, Muhammad

    2015-01-01

    The most commonly used technique to separate oil and cake from J. curcas seeds is mechanical extraction. It uses simple tools such as a piston and a screw extruder to produce high pressure, driven by hand or by engine. A single screw extruder has one screw rotating inside the barrel and materials simultaneously flow from the feed to the die zone. The highest oil yield can be obtained by a well-designed oil press as well as finding the optimum conditions for all parameters involved during the ...

  5. Why unify

    International Nuclear Information System (INIS)

    Georgi, H.

    1980-01-01

    Unified gauge theories such as SU(5) of particle interactions are built on the colour SU(3) and SU(2) x U(1) gauge theories which apparently describe strong and weak and electromagnetic interactions at distances as small as 10 -16 cm. In this article the classical reasons for going beyond SU(3)xSU(2)xU(1) to a fully unified theory such as SU(5) are reviewed, and a new reason formulated. A class of imaginary worlds similar to our own is considered and it is shown that unification is possible only in ours. This suggests that the low-energy interactions are unique in that they are constructed to make unification possible. (author)

  6. Landau quantization, Aharonov–Bohm effect and two-dimensional pseudoharmonic quantum dot around a screw dislocation

    International Nuclear Information System (INIS)

    Filgueiras, Cleverson; Rojas, Moises; Aciole, Gilson; Silva, Edilberto O.

    2016-01-01

    Highlights: • We derive the Schrödinger equation for an electron around a screw dislocation in the presence of an external magnetic field. • We consider the electron confined on an interface. • Modifications due to the screw dislocation on the light interband absorption coefficient and absorption threshold frequency. - Abstract: We investigate the influence of a screw dislocation on the energy levels and the wavefunctions of an electron confined in a two-dimensional pseudoharmonic quantum dot under the influence of an external magnetic field inside a dot and Aharonov–Bohm field inside a pseudodot. The exact solutions for energy eigenvalues and wavefunctions are computed as functions of applied uniform magnetic field strength, Aharonov–Bohm flux, magnetic quantum number and the parameter characterizing the screw dislocation, the Burgers vector. We investigate the modifications due to the screw dislocation on the light interband absorption coefficient and absorption threshold frequency. Two scenarios are possible, depending on if singular effects either manifest or not. We found that as the Burgers vector increases, the curves of frequency are pushed up towards of the growth of it. One interesting aspect which we have observed is that the Aharonov–Bohm flux can be tuned in order to cancel the screw effect of the model.

  7. Landau quantization, Aharonov–Bohm effect and two-dimensional pseudoharmonic quantum dot around a screw dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Filgueiras, Cleverson, E-mail: cleverson.filgueiras@dfi.ufla.br [Departamento de Física, Universidade Federal de Lavras, Caixa Postal 3037, 37200-000, Lavras, MG (Brazil); Rojas, Moises, E-mail: moises.leyva@dfi.ufla.br [Departamento de Física, Universidade Federal de Lavras, Caixa Postal 3037, 37200-000, Lavras, MG (Brazil); Aciole, Gilson [Unidade Acadêmica de Física, Universidade Federal de Campina Grande, POB 10071, 58109-970, Campina Grande, PB (Brazil); Silva, Edilberto O., E-mail: edilberto.silva@ufma.br [Departamento de Física, Universidade Federal do Maranhão, 65085-580, São Luís, MA (Brazil)

    2016-11-25

    Highlights: • We derive the Schrödinger equation for an electron around a screw dislocation in the presence of an external magnetic field. • We consider the electron confined on an interface. • Modifications due to the screw dislocation on the light interband absorption coefficient and absorption threshold frequency. - Abstract: We investigate the influence of a screw dislocation on the energy levels and the wavefunctions of an electron confined in a two-dimensional pseudoharmonic quantum dot under the influence of an external magnetic field inside a dot and Aharonov–Bohm field inside a pseudodot. The exact solutions for energy eigenvalues and wavefunctions are computed as functions of applied uniform magnetic field strength, Aharonov–Bohm flux, magnetic quantum number and the parameter characterizing the screw dislocation, the Burgers vector. We investigate the modifications due to the screw dislocation on the light interband absorption coefficient and absorption threshold frequency. Two scenarios are possible, depending on if singular effects either manifest or not. We found that as the Burgers vector increases, the curves of frequency are pushed up towards of the growth of it. One interesting aspect which we have observed is that the Aharonov–Bohm flux can be tuned in order to cancel the screw effect of the model.

  8. [Odontoid bending stiffness after anterior fixation with a single lag screw: biomechanical study].

    Science.gov (United States)

    Buchvald, P; Čapek, L; Barsa, P

    2015-01-01

    PURPOSE OF THE STUDY The aim of the experiment was to compare the bending stiffness of an intact odontoid process with bending stiffness after its simulated type II fracture was fixed with a single lag screw. The experiment was done with a desire to answer the question of whether a single osteosynthetic screw is sufficient for good fixation of a type II odontoid fracture. MATERIAL AND METHODS The C2 vertebrae of six cadavers were used. With simultaneous measurement of odontoid bending stiffness, the occurrence of a fracture (type IIA, Grauer's modification of the Anderson- D'Alonzo classification) was simulated using action exerted by a tearing machine in the direction perpendicular to the odontoid axis. Each odontoid fracture was subsequently treated by direct osteosynthesis with a single lag screw inserted in the axial direction by a standard surgical procedure in order to provide conditions similar to those achieved by routine surgical management. The treated odontoid process was subsequently subjected to the same tearing machine loading as applied to it at the start of the experiment. The bending stiffness measured was then compared with that found before the fracture occurred. The results were statistically evaluated by the t-test for paired samples at the level of significance α = 0.05. RESULTS The average value of bending stiffness for odontoid processes of intact vertebrae at the moment of fracture occurrence was 318.3 N/mm. After single axial lag screw fixation of the fracture, the average bending stiffness for the odontoid processes treated was 331.3 N/mm. DISCUSSION Higher values of bending stiffness after screw fixation were found in all specimens and, in comparison with the values recorded before simulated fractures, the increase was statistically significant. CONCLUSIONS The results of our measurements suggest that the single lag screw fixation of a type IIA odontoid fracture will provide better stability for the fracture fragment-C2 body complex on

  9. Pullout characteristics of percutaneous pedicle screws with different cement augmentation methods in elderly spines: An in vitro biomechanical study.

    Science.gov (United States)

    Charles, Y P; Pelletier, H; Hydier, P; Schuller, S; Garnon, J; Sauleau, E A; Steib, J-P; Clavert, P

    2015-05-01

    Vertebroplasty prefilling or fenestrated pedicle screw augmentation can be used to enhance pullout resistance in elderly patients. It is not clear which method offers the most reliable fixation strength if axial pullout and a bending moment is applied. The purpose of this study is to validate a new in vitro model aimed to reproduce a cut out mechanism of lumbar pedicle screws, to compare fixation strength in elderly spines with different cement augmentation techniques and to analyze factors that might influence the failure pattern. Six human specimens (82-100 years) were instrumented percutaneously at L2, L3 and L4 by non-augmented screws, vertebroplasty augmentation and fenestrated screws. Cement distribution (2 ml PMMA) was analyzed on CT. Vertebral endplates and the rod were oriented at 45° to the horizontal plane. The vertebral body was held by resin in a cylinder, linked to an unconstrained pivot, on which traction (10 N/s) was applied until rupture. Load-displacement curves were compared to simultaneous video recordings. Median pullout forces were 488.5 N (195-500) for non-augmented screws, 643.5 N (270-1050) for vertebroplasty augmentation and 943.5 N (750-1084) for fenestrated screws. Cement augmentation through fenestrated screws led to significantly higher rupture forces compared to non-augmented screws (P=0.0039). The pullout force after vertebroplasty was variable and linked to cement distribution. A cement bolus around the distal screw tip led to pullout forces similar to non-augmented screws. A proximal cement bolus, as it was observed in fenestrated screws, led to higher pullout resistance. This cement distribution led to vertebral body fractures prior to screw pullout. The experimental setup tended to reproduce a pullout mechanism observed on radiographs, combining axial pullout and a bending moment. Cement augmentation with fenestrated screws increased pullout resistance significantly, whereas the fixation strength with the vertebroplasty

  10. MIS Single-position Lateral and Oblique Lateral Lumbar Interbody Fusion and Bilateral Pedicle Screw Fixation: Feasibility and Perioperative Results.

    Science.gov (United States)

    Blizzard, Daniel J; Thomas, J Alex

    2018-03-15

    Retrospective review of prospectively collected data of the first 72 consecutive patients treated with single-position one- or two-level lateral (LLIF) or oblique lateral interbody fusion (OLLIF) with bilateral percutaneous pedicle screw and rod fixation by a single spine surgeon. To evaluate the clinical feasibility, accuracy, and efficiency of a single-position technique for LLIF and OLLIF with bilateral pedicle screw and rod fixation. Minimally-invasive lateral interbody approaches are performed in the lateral decubitus position. Subsequent repositioning prone for bilateral pedicle screw and rod fixation requires significant time and resources and does not facilitate increased lumbar lordosis. The first 72 consecutive patients (300 screws) treated with single-position LLIF or OLLIF and bilateral pedicle screws by a single surgeon between December 2013 and August 2016 were included in the study. Screw accuracy and fusion were graded using computed tomography and several timing parameters were recorded including retractor, fluoroscopy, and screw placement time. Complications including reoperation, infection, and postoperative radicular pain and weakness were recorded. Average screw placement time was 5.9 min/screw (standard deviation, SD: 1.5 min; range: 3-9.5 min). Average total operative time (interbody cage and pedicle screw placement) was 87.9 minutes (SD: 25.1 min; range: 49-195 min). Average fluoroscopy time was 15.0 s/screw (SD: 4.7 s; range: 6-25 s). The pedicle screw breach rate was 5.1% with 10/13 breaches measured as < 2 mm in magnitude. Fusion rate at 6-months postoperative was 87.5%. Two (2.8%) patients underwent reoperation for malpositioned pedicle screws with subsequent resolution of symptoms. The single-position, all-lateral technique was found to be feasible with accuracy, fluoroscopy usage, and complication rates comparable with the published literature. This technique eliminates the time and staffing associated with

  11. ''Old'' locked inflation

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Yang; Piao, Yun-Song [College of Physical Sciences, Graduate University of Chinese Academy of Sciences, Beijing 100049 (China); Si, Zong-Guo, E-mail: liuyangbyf@mail.sdu.edu.cn, E-mail: yspiao@gucas.ac.cn, E-mail: zgsi@sdu.edu.cn [Department of Physics, Shandong University, Jinan 250100 (China)

    2009-05-15

    In this paper, we revisit the idea of locked inflation, which does not require a potential satisfying the normal slow-roll condition, but suffers from the problems associated with ''saddle inflation''. We propose a scenario based on locked inflation, however, with an alternative evolution mechanism of the ''waterfall field'' {phi}. Instead of rolling down along the potential, the {phi} field will tunnel to end the inflation stage like in old inflation, by which the saddle inflation could be avoided. Further, we study a cascade of old locked inflation, which can be motivated by the string landscape. Our model is based on the consideration of making locked inflation feasible so as to give a working model without slow roll; It also can be seen as an effort to embed the old inflation in string landscape.

  12. Improving generalized inverted index lock wait times

    Science.gov (United States)

    Borodin, A.; Mirvoda, S.; Porshnev, S.; Ponomareva, O.

    2018-01-01

    Concurrent operations on tree like data structures is a cornerstone of any database system. Concurrent operations intended for improving read\\write performance and usually implemented via some way of locking. Deadlock-free methods of concurrency control are known as tree locking protocols. These protocols provide basic operations(verbs) and algorithm (ways of operation invocations) for applying it to any tree-like data structure. These algorithms operate on data, managed by storage engine which are very different among RDBMS implementations. In this paper, we discuss tree locking protocol implementation for General inverted index (Gin) applied to multiversion concurrency control (MVCC) storage engine inside PostgreSQL RDBMS. After that we introduce improvements to locking protocol and provide usage statistics about evaluation of our improvement in very high load environment in one of the world’s largest IT company.

  13. CT-based bone density assessment for iliosacral screw trajectories

    Directory of Open Access Journals (Sweden)

    Andreas Schicho

    2016-01-01

    Full Text Available Introduction: Sacroiliac screw placement is one standard treatment option for stabilization of posterior pelvic ring injuries encountering high intra- and inter-individual variations of bone stock quality as well as a vast variety and prevalence of sacral dysmorphism. An individual, easy-to-use preoperative bone stock quality estimation would be of high value for the surgeon. Materials and Methods: We analyzed 36 standard computed tomography datasets with the uninjured pelvic ring. Using a two-plane cross-referencing technique, we assessed the Hounsfield unit (HU mean values as well as standard deviation and minimum/maximum values within selected region of interests (ROIs at five key areas: os ilium left and right, massa lateralis of os sacrum left and right, and central vertebral body on levels S1 and S2. Results: Results showed no difference in mean HU at any ROI when comparing male and female data. For all ROIs set on S1 and S2, there was an age-related decline of HU with a calculated slope significantly different from zero. There was no statistical difference of slopes when comparing S1- and S2-level with respect to any distinct ROI. Comparison of levels S1 and S2 revealed differences at the vertebral body and at the right os ilium. The right and left massa lateralis of os sacrum had lower bone density than the center of the vertebral body, the right, or left os ilium on S1; right and left massa lateralis density did not differ significantly. On level S2, results were comparable with no difference of massa lateralis density. Conclusion: With our easy-to-use preoperative assessment of bone density of five key areas of sacroiliac screw anchoring we were able to find the lowest bone density in both the left and right massa lateralis on levels S1 and S2 with high inter- and intra-individual variations. Significantly lower bone density was found in the center of the vertebral bodies S2 in comparison to S1, which both are crucial for iliosacral

  14. Kinematics of a Hybrid Manipulator by Means of Screw Theory

    International Nuclear Information System (INIS)

    Gallardo-Alvarado, J

    2005-01-01

    In this work the kinematics of a hybrid manipulator, namely a fully parallel-serial manipulator, with a particular topology is approached by means of the theory of screws. Given the length of the six independent limbs, the forward position analysis of the mechanism under study, indeed the computation of the resulting pose, position and orientation, of the end-platform with respect to the fixed platform, is carried out in closed-form solution. Therefore conveniently this initial analysis avoids the use of a numerical technique such as the Newton-Raphson method. Writing in screw form the reduced acceleration state of the translational platform, with respect to the fixed platform, a simple expression for the computation of the acceleration of the translational platform is derived by taking advantage of the properties of reciprocal screws, via the Klein form, a bilinear symmetric form of the Lie algebra e(3). Following a similar procedure, a simple expression for the computation of the angular acceleration of the end-platform, with respect to the translational platform, is easily derived. Naturally, as an intermediate step, this contribution also provides the forward and inverse velocity analyses of the chosen parallel-serial manipulator. Finally, in order to prove the versatility of the expressions obtained via screw theory for solving the kinematics, up to the acceleration analysis, of the proposed spatial mechanism, a numerical example is solved with the help of commercial computer codes

  15. John locke on personal identity.

    Science.gov (United States)

    Nimbalkar, Namita

    2011-01-01

    John Locke speaks of personal identity and survival of consciousness after death. A criterion of personal identity through time is given. Such a criterion specifies, insofar as that is possible, the necessary and sufficient conditions for the survival of persons. John Locke holds that personal identity is a matter of psychological continuity. He considered personal identity (or the self) to be founded on consciousness (viz. memory), and not on the substance of either the soul or the body.

  16. John Locke on Personal Identity**

    OpenAIRE

    Nimbalkar, Namita

    2011-01-01

    John Locke speaks of personal identity and survival of consciousness after death. A criterion of personal identity through time is given. Such a criterion specifies, insofar as that is possible, the necessary and sufficient conditions for the survival of persons. John Locke holds that personal identity is a matter of psychological continuity. He considered personal identity (or the self) to be founded on consciousness (viz. memory), and not on the substance of either the soul or the body.

  17. Injection locking of optomechanical oscillators via acoustic waves

    Science.gov (United States)

    Huang, Ke; Hossein-Zadeh, Mani

    2018-04-01

    Injection locking is a powerful technique for synchronization of oscillator networks and controlling the phase and frequency of individual oscillators using similar or other types of oscillators. Here, we present the first demonstration of injection locking of a radiation-pressure driven optomechanical oscillator (OMO) via acoustic waves. As opposed to previously reported techniques (based on pump modulation or direct application of a modulated electrostatic force), injection locking of OMO via acoustic waves does not require optical power modulation or physical contact with the OMO and it can easily be implemented on various platforms. Using this approach we have locked the phase and frequency of two distinct modes of a microtoroidal silica OMO to a piezoelectric transducer (PZT). We have characterized the behavior of the injection locked OMO with three acoustic excitation configurations and showed that even without proper acoustic impedance matching the OMO can be locked to the PZT and tuned over 17 kHz with only -30 dBm of RF power fed to the PZT. The high efficiency, simplicity and scalability of the proposed approach paves the road toward a new class of photonic systems that rely on synchronization of several OMOs to a single or multiple RF oscillators with applications in optical communication, metrology and sensing. Beyond its practical applications, injection locking via acoustic waves can be used in fundamental studies in quantum optomechanics where thermal and optical isolation of the OMO are critical.

  18. Taurolidine lock is superior to heparin lock in the prevention of catheter related bloodstream infections and occlusions.

    Directory of Open Access Journals (Sweden)

    Evelyn D Olthof

    Full Text Available Patients on home parenteral nutrition (HPN are at risk for catheter-related complications; mainly infections and occlusions. We have previously shown in HPN patients presenting with catheter sepsis that catheter locking with taurolidine dramatically reduced re-infections when compared with heparin. Our HPN population therefore switched from heparin to taurolidine in 2008. The aim of the present study was to compare long-term effects of this catheter lock strategy on the occurrence of catheter-related bloodstream infections and occlusions in HPN patients.Data of catheter-related complications were retrospectively collected from 212 patients who received HPN between January 2000 and November 2011, comprising 545 and 200 catheters during catheter lock therapy with heparin and taurolidine, respectively. We evaluated catheter-related bloodstream infection and occlusion incidence rates using Poisson-normal regression analysis. Incidence rate ratios were calculated by dividing incidence rates of heparin by those of taurolidine, adjusting for underlying disease, use of anticoagulants or immune suppressives, frequency of HPN/fluid administration, composition of infusion fluids, and duration of HPN/fluid use before catheter creation.Bloodstream infection incidence rates were 1.1/year for heparin and 0.2/year for taurolidine locked catheters. Occlusion incidence rates were 0.2/year for heparin and 0.1/year for taurolidine locked catheters. Adjusted incidence ratios of heparin compared to taurolidine were 5.9 (95% confidence interval, 3.9-8.7 for bloodstream infections and 1.9 (95% confidence interval, 1.1-3.1 for occlusions.Given that no other procedural changes than the catheter lock strategy were implemented during the observation period, these data strongly suggest that taurolidine decreases catheter-related bloodstream infections and occlusions in HPN patients compared with heparin.

  19. Seven Deadliest Unified Communications Attacks

    CERN Document Server

    York, Dan

    2010-01-01

    Do you need to keep up with the latest hacks, attacks, and exploits effecting Unified Communications technology? Then you need Seven Deadliest Unified Communication Attacks. This book pinpoints the most dangerous hacks and exploits specific to Unified Communications, laying out the anatomy of these attacks including how to make your system more secure. You will discover the best ways to defend against these vicious hacks with step-by-step instruction and learn techniques to make your computer and network impenetrable. Attacks featured in this book include: UC Ecosystem Attacks Insecure Endpo

  20. Coupled optical resonance laser locking.

    Science.gov (United States)

    Burd, S C; du Toit, P J W; Uys, H

    2014-10-20

    We have demonstrated simultaneous laser frequency stabilization of a UV and IR laser, to coupled transitions of ions in the same spectroscopic sample, by detecting only the absorption of the UV laser. Separate signals for locking the different lasers are obtained by modulating each laser at a different frequency and using lock-in detection of a single photodiode signal. Experimentally, we simultaneously lock a 369 nm and a 935 nm laser to the (2)S(1/2) → (2)(P(1/2) and (2)D(3/2) → (3)D([3/2]1/2) transitions, respectively, of Yb(+) ions generated in a hollow cathode discharge lamp. Stabilized lasers at these frequencies are required for cooling and trapping Yb(+) ions, used in quantum information and in high precision metrology experiments. This technique should be readily applicable to other ion and neutral atom systems requiring multiple stabilized lasers.

  1. Effect of Cortical Screw Diameter on Reduction and Stabilization of Type III Distal Phalanx Fractures: An Equine Cadaveric Study.

    Science.gov (United States)

    Kay, Alastair T; Durgam, Sushmitha; Stewart, Matthew; Joslyn, Stephen; Schaeffer, David J; Horn, Gavin; Kesler, Richard; Chew, Peter

    2016-11-01

    To compare reduction of type III distal phalangeal fractures using 4.5 and 5.5 mm cortical screws placed in lag fashion and an intact hoof capsule model. Cadaveric experimental study. Hooves from 12 adult horses (n=24). Sagittal fractures were created in pairs of distal phalanges after distal interphalangeal joint disarticulation and were reduced with either 4.5 or 5.5 mm cortical screws placed in lag fashion. Contralateral phalanges served as non-reduced controls. Fracture reduction following screw placement was assessed by comparing pre-reduction and post-reduction fracture gap measurements from radiographs using paired t-tests. Effects of incremental loading (0, 135, 270, 540, 800, 1070, and 1335 kg) on fracture gaps in 6 phalanges reduced with 4.5 mm screws and 5 phalanges reduced with 5.5 mm screws were measured from fluoroscopic images and assessed by 2-way ANOVA. Significance was set at Pfractures were reliably created. Only 5.5 mm cortical screws, not 4.5 mm screws, significantly reduced fracture gaps and constrained fracture gap expansion 3 cm distal to the articular surface. Compressive loading closed the fracture gaps at the articular surface in both non-reduced control groups and those reduced with either 5.5 or 4.5 mm screws. The 5.5 mm cortical screws were more effective than 4.5 mm screws in reducing type III distal phalanx fractures and restricting distal fracture gap expansion under load. © Copyright 2016 by The American College of Veterinary Surgeons.

  2. Determination of Screw and Nail Withdrawal Strengths in Parallel and Perpendicular to Grain of some Hardwoods of Iran

    Directory of Open Access Journals (Sweden)

    Sadegh Maleki

    2013-06-01

    Full Text Available In this study, screw and nail withdrawal strengths parallel and perpendicular longitudinal to grain of some hardwoods; oak (Quercus castaneifolia, hornbeam (Carpinus betulus, beech (Fagus orientalis, Sycamore (Platanus oriantalis and poplar (Populus deltoids were investigated. The tests were conducted following ASTM D 1761 with specimen dimension of 15×5×5(T×R×L. Three kinds of screws namely sheet metal screw, wood screw and coarse drywall screw with diameter of 4 and 5 mm were used. Three different nails with nominal diameter of 2.5, 3.25 and 3.75 mm were also used. The highest screw withdrawal strengths parallel and perpendicular to grain were related to hornbeam, beech, oak, Sycamore and poplar respectively. Furthermore, the highest nail withdrawal strengths parallel and perpendicular to grain were related to hornbeam, oak, beech, Sycamore and poplar respectively for nails with 3.75 mm diameter. Higher density and shear strength of hornbeam compared to the other species accounts for its high screw and nail withdrawal strengths parallel and perpendicular to grain.

  3. Genomic and Functional Characterization of the Unusual pLOCK 0919 Plasmid Harboring the spaCBA Pili Cluster in Lactobacillus casei LOCK 0919

    Science.gov (United States)

    Aleksandrzak-Piekarczyk, Tamara; Koryszewska-Bagińska, Anna; Grynberg, Marcin; Nowak, Adriana; Cukrowska, Bożena; Kozakova, Hana; Bardowski, Jacek

    2016-01-01

    Here, we report the extensive bioinformatic and functional analyses of the unusual pLOCK 0919, a plasmid originating from the probiotic Lactobacillus casei LOCK 0919 strain. This plasmid is atypical because it harbors the spaCBA-srtC gene cluster encoding SpaCBA pili. We show that all other spaCBA-srtC sequences of the Lactobacillus genus that have been previously described and deposited in GenBank are present in the chromosomal DNA. Another important observation for pLOCK 0919 is that the spaCBA-srtC gene cluster and its surrounding genes are highly similar to the respective DNA region that is present in the most well-known and active SpaCBA pili producer, the probiotic Lactobacillus rhamnosus GG strain. Our results demonstrate that the spaCBA-srtC clusters of pLOCK 0919 and L. rhamnosus GG are genealogically similar, located in DNA regions that are rich in transposase genes and are poorly conserved among the publicly available sequences of Lactobacillus sp. In contrast to chromosomally localized pilus gene clusters from L. casei and Lactobacillus paracasei, the plasmidic spaC of L. casei LOCK 0919 is expressed and undergoes a slight glucose-induced repression. Moreover, results of series of in vitro tests demonstrate that L. casei LOCK 0919 has an adhesion potential, which is largely determined by the presence of the pLOCK 0919 plasmid. In particular, the plasmid occurrence positively influenced the hydrophobicity and aggregation abilities of L. casei LOCK 0919. Moreover, in vivo studies indicate that among the three Lactobacillus strains used to colonize the gastrointestinal tract of germ-free mice, already after 2 days of colonization, L. casei LOCK 0919 became the dominant strain and persisted there for at least 48 days. PMID:26637469

  4. Close Intramedullary Interlocking Nailing Versus Locking Compression Plating In the Treatment of Closed Fracture Shaft of the Tibia.

    Science.gov (United States)

    Kundu, I K; Datta, N K; Chowdhury, A Z; Das, K P; Tarik, M M; Faisal, M A

    2016-07-01

    Fracture of tibial shaft is the commonest site of long bone fractures due to its superficial location involving young or middle-age people. Proper management is an important issue regarding the future effective movements. In this study patients were grouped in closed Intra medullary interlocking nailing and locking compression plating. Post-operative follow up at 2 weeks, 6 weeks, 12 weeks and 3 months thereafter up to 6 months were done. Each of the patients was evaluated clinically and radiologically by tucker criteria of Tuker et al. Patients were assessed for pain on full weight bearing and kneeling, shortening and range of motion of knee and ankle joints. Radiological assessment for union of fracture, alignment of fracture and angulations and position of nail and screws and infection were observed during follow up. A total number of 32 patients were selected but only 27 patients were available for follow up for a period of 6 months. They were grouped into Group A, consisting of 15 patients who took the treatment in the form of closed intramedullary interlocking nailing and Group B, consisting of 12 patients those underwent ORIF with locking compression plating. In both of the groups Motor Vehicle Accident was the main mechanism of trauma. Fracture involving the middle 3rd of the tibia is common in both the groups. During post-operative follow up, four patients in Group A complained anterior knee pain, one patient in Group B had superficial infection, most of the patients had no restriction of movement in the ankle and knee joints and a single patient in Group B showed 1.5cm shortening of the lower limb. Period of hospital stay and fracture union time were less in Group A, which was statistically significant. Both groups showed excellent result with minimum complications. So this study permits to conclude that close IM interlocking nailing and open reduction and internal fixation by locking compression plating is equally effective for the management of close

  5. Plate Versus Intramedullary Nail Fixation of Anterior Tibial Stress Fractures: A Biomechanical Study.

    Science.gov (United States)

    Markolf, Keith L; Cheung, Edward; Joshi, Nirav B; Boguszewski, Daniel V; Petrigliano, Frank A; McAllister, David R

    2016-06-01

    Anterior midtibial stress fractures are an important clinical problem for patients engaged in high-intensity military activities or athletic training activities. When nonoperative treatment has failed, intramedullary (IM) nail and plate fixation are 2 surgical options used to arrest the progression of a fatigue fracture and allow bone healing. A plate will be more effective than an IM nail in preventing the opening of a simulated anterior midtibial stress fracture from tibial bending. Controlled laboratory study. Fresh-frozen human tibias were loaded by applying a pure bending moment in the sagittal plane. Thin transverse saw cuts, 50% and 75% of the depth of the anterior tibial cortex, were created at the midtibia to simulate a fatigue fracture. An extensometer spanning the defect was used to measure the fracture opening displacement (FOD) before and after the application of IM nail and plate fixation constructs. IM nails were tested without locking screws, with a proximal screw only, and with proximal and distal screws. Plates were tested with unlocked bicortical screws (standard compression plate) and locked bicortical screws; both plate constructs were tested with the plate edge placed 1 mm from the anterior tibial crest (anterior location) and 5 mm posterior to the crest. For the 75% saw cut depth, the mean FOD values for all IM nail constructs were 13% to 17% less than those for the saw cut alone; the use of locking screws had no significant effect on the FOD. The mean FOD values for all plate constructs were significantly less than those for all IM nail constructs. The mean FOD values for all plates were 28% to 46% less than those for the saw cut alone. Anterior plate placement significantly decreased mean FOD values for both compression and locked plate constructs, but the mean percentage reductions for locked and unlocked plates were not significantly different from each other for either plate placement. The percentage FOD reductions for all plate

  6. Analysis of peer-to-peer locking of magnetrons

    International Nuclear Information System (INIS)

    Pengvanich, P.; Lau, Y. Y.; Cruz, E.; Gilgenbach, R. M.; Hoff, B.; Luginsland, J. W.

    2008-01-01

    The condition for mutual, or peer-to-peer, locking of two magnetrons is derived. This condition reduces to Adler's classical phase-locking condition in the limit where one magnetron becomes the ''master'' and the other becomes the ''slave.'' The formulation is extended to the peer-to-peer locking of N magnetrons, under the assumption that the electromagnetic coupling among the N magnetrons is modeled by an N-port network.

  7. Stability of biodegradable metal (Mg-Ca-Zn alloy) screws compared with absorbable polymer and titanium screws for sagittal split ramus osteotomy of the mandible using the finite element analysis model.

    Science.gov (United States)

    Lee, Jee-Ho; Han, Hyung-Seop; Kim, Yu-Chan; Lee, Jin-Yong; Lee, Bu-Kyu

    2017-10-01

    Mg-Ca-Zn alloy has been suggested for the application of fixation materials during maxillofacial surgery. We investigated the stability of Mg-Ca-Zn alloy for clinical application during orthognathic surgery. The finite element model for the fixation of sagittal split ramus osteotomy was constructed. In the bicortical screw fixation of the mandible setback condition, the stress distributions of Mg-Ca-Za alloy, polylactic acid polymer, and titanium were evaluated using the virtual model with occlusal loading of 132 N. The deformations of the three different materials of fixation screw were observed according to masticatory force ranging from 132 to 1,000 N. When comparing the stress distribution placed on cortical bone between the polymer and magnesium alloy groups, the magnesium alloy screws could bear more stress, thereby decreasing the stress, which might be distributed to other biologic components, such as the condyle and cortical ramus of the mandible. Deformations of the screws according to functional load were minimal, and the deformation remained stability of sagittal split ramus osteotomy setback surgery. Copyright © 2017. Published by Elsevier Ltd.

  8. High failure rate of trochanteric fracture osteosynthesis with proximal femoral locking compression plate.

    Science.gov (United States)

    Wirtz, C; Abbassi, F; Evangelopoulos, D S; Kohl, S; Siebenrock, K A; Krüger, A

    2013-06-01

    Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. Early results for PF-LCP osteosynthesis show major

  9. ELB-trees - Efficient Lock-free B+trees

    DEFF Research Database (Denmark)

    Bonnichsen, Lars Frydendal; Karlsson, Sven; Probst, Christian W.

    2014-01-01

    As computer systems scale in the number of processors, data structures with good parallel performance become increasingly important. Lock-free data structures promise improved parallel performance at the expense of higher complexity and sequential execution time.We present ELBtrees, a new lock-fr...

  10. Hew Locke: House of Cards

    OpenAIRE

    Reckitt, Helena; Joyce, Julie; Locke, Hew

    2004-01-01

    ‘Hew Locke: House of Cards’ featured a selection of the artist's portraits of British royalty in various media, and his response to other trappings of the monarchy and empire. The show included works previously exhibited at the Luckman Gallery, Los Angeles, in tandem with a newly commissioned coat of arms, and other recent works. \\ud \\ud Locke draws from everyday sources, ranging from items found in London's Brixton Market to discount fabric shops and thrift stores. Other sources of inspirati...

  11. Locking compression plate osteosynthesis of complicated mandibular fractures in six horses.

    Science.gov (United States)

    Kuemmerle, J M; Kummer, M; Auer, J A; Nitzl, D; Fürst, A E

    2009-01-01

    Complicated mandibular fractures were recognised in one foal, one pony and four horses. The foal was two months old while the adult animals ranged in age from 12 to 24 years. Three horses had a unilateral horizontal ramus fracture. Two fractures were open and one was closed. Comminution was present in one of these patients while the other two horses had marked displacement of the fragments. Two suffered from comminuted fractures of the horizontal and vertical ramus of the mandible. One of these patients had open and infected fractures. One foal had a bilateral horizontal ramus fracture with marked periosteal 'new bone' formation and malalignement which required corrective osteotomy. Each horse underwent locking compression plate (LCP) osteosynthesis consisting of open fracture reduction and application of one to three 4.5/5.0 mm LCP at the ventral, lateral or caudal aspect of the mandible under fluoroscopic control. Two 3.5 mm LCP were used in the foal. Plate fixation was supported by application of a cerclage wire construct between the incisor and premolar teeth in most patients. Complete fracture healing, with an excellent functional and cosmetic outcome, was achieved in all of the patients. Complications encountered included seroma formation, screw and wire breakage, as well as implant and apical tooth root infections. The LCP was removed after fracture healing had occurred in four patients.

  12. Unifying Abstractions

    DEFF Research Database (Denmark)

    Torgersen, Mads

    This thesis presents the RUNE language, a semantic construction of related and tightly coupled programming constructs presented in the shape of a programming language. The major contribution is the succesfull design of a highly unified and general programming model, capable of expressing some of ...... a unified name declaration mechanism. The resulting expressiveness allows for argument covariance, dependent types and module types, plus a solution to the so-called expression problem of two way extensibility in object-oriented languages....... of the most complex type relations put forth in type systems research, without compromising such fundamental qualities as conceptuality, modularity and static typing. While many new constructs and unifications are put forth  to substantiate their conceptual validity, type rules are given to support...

  13. Modeling of mode-locked coupled-resonator optical waveguide lasers

    DEFF Research Database (Denmark)

    Agger, Christian; Skovgård, Troels Suhr; Gregersen, Niels

    2010-01-01

    Coupled-resonator optical waveguides made from coupled high-Q photonic crystal nanocavities are investigated for use as cavities in mode-locked lasers. Such devices show great potential in slowing down light and can serve to reduce the cavity length of a mode-locked laser. An explicit expression...... of the emerging pulse train. A range of tuning around this frequency allows for effective mode locking. Finally, noise is added to the generalized single-cavity eigenfrequencies in order to evaluate the effects of fabrication imperfections on the cold-cavity transmission properties and consequently on the locking...

  14. A phenomenological study on twin screw extruders

    NARCIS (Netherlands)

    Janssen, L.P.B.M.

    1976-01-01

    Although more and more twin screw extruders are being used in the polymer industry, the theoretical background is relatively undeveloped. The literature abounds in contradictions and often informs the reader that all extrusion problems can be solved if a certain new design is considered. The

  15. Improving the API dissolution rate during pharmaceutical hot-melt extrusion I: Effect of the API particle size, and the co-rotating, twin-screw extruder screw configuration on the API dissolution rate.

    Science.gov (United States)

    Li, Meng; Gogos, Costas G; Ioannidis, Nicolas

    2015-01-15

    The dissolution rate of the active pharmaceutical ingredients in pharmaceutical hot-melt extrusion is the most critical elementary step during the extrusion of amorphous solid solutions - total dissolution has to be achieved within the short residence time in the extruder. Dissolution and dissolution rates are affected by process, material and equipment variables. In this work, we examine the effect of one of the material variables and one of the equipment variables, namely, the API particle size and extruder screw configuration on the API dissolution rate, in a co-rotating, twin-screw extruder. By rapidly removing the extruder screws from the barrel after achieving a steady state, we collected samples along the length of the extruder screws that were characterized by polarized optical microscopy (POM) and differential scanning calorimetry (DSC) to determine the amount of undissolved API. Analyses of samples indicate that reduction of particle size of the API and appropriate selection of screw design can markedly improve the dissolution rate of the API during extrusion. In addition, angle of repose measurements and light microscopy images show that the reduction of particle size of the API can improve the flowability of the physical mixture feed and the adhesiveness between its components, respectively, through dry coating of the polymer particles by the API particles. Copyright © 2014. Published by Elsevier B.V.

  16. Dual head screw hip nailing for trochanteric fractures

    Science.gov (United States)

    Mavrogenis, Andreas F.; Igoumenou, Vasilios G.; Megaloikonomos, Panayiotis D.; Panagopoulos, George N.; Galanopoulos, Ioannis P.; Vottis, Christos Th.; Karamanis, Eirinaios; Koulouvaris, Panayiotis; Papagelopoulos, Panayiotis J.

    2017-01-01

    Introduction: There are limited information and inconclusive results for dual head screw intramedullary hip nails for trochanteric fractures. Therefore, we performed a prospective study to evaluate the healing of fractures, and survival, function, and complications of patients operated with this implant. Methods: We prospectively studied 79 patients (61 women and 18 men; mean age: 84.7 years; range: 65–96 years) with a low-energy trochanteric fracture, treated with a dual head screw intramedullary hip nail from 2013 to 2016. The mean follow-up was 2.1 years (range: 1–3 years); seven patients were lost to follow up. This left 72 patients for further analysis. We evaluated the healing of fractures, and survival, function, and complications of patients. Results: Fracture healing was evident in 70 patients (97.2%) at 2–3 months postoperatively. One patient experienced cut-out and z-effect phenomenon of the head screws. Another patient experienced a periprosthetic femoral diaphysis fracture at the distal tip of the nail. A third patient experienced an acute postoperative superficial skin infection that was treated successfully with wound dressing changes and a course of antibiotics. Sixteen patients (22.2%) deceased within 12 months postoperatively. In the remaining patients, the Harris Hip Score (HHS) at 12 months postoperatively was excellent in 16 (28.6%), good in 23 (41.1%), fair in 10 (17.8%), and poor in 7 patients (12.5%). The function declined after the patients’ fracture. Fair and poor results were related to age > 85 years, poor pre-fracture level of function, and AO/OTA-31-A3 fracture types. Conclusion: The dual head screw intramedullary hip nail is associated with high healing and low complication rates for intertrochanteric fractures. The function of the patients is good or excellent in most cases; however, it declines, especially for those patients with age > 85 years, poor pre-fracture level of function, and AO/OTA-31-A3 fracture types

  17. Dual head screw hip nailing for trochanteric fractures

    Directory of Open Access Journals (Sweden)

    Mavrogenis Andreas F.

    2017-01-01

    Full Text Available Introduction: There are limited information and inconclusive results for dual head screw intramedullary hip nails for trochanteric fractures. Therefore, we performed a prospective study to evaluate the healing of fractures, and survival, function, and complications of patients operated with this implant. Methods: We prospectively studied 79 patients (61 women and 18 men; mean age: 84.7 years; range: 65–96 years with a low-energy trochanteric fracture, treated with a dual head screw intramedullary hip nail from 2013 to 2016. The mean follow-up was 2.1 years (range: 1–3 years; seven patients were lost to follow up. This left 72 patients for further analysis. We evaluated the healing of fractures, and survival, function, and complications of patients. Results: Fracture healing was evident in 70 patients (97.2% at 2–3 months postoperatively. One patient experienced cut-out and z-effect phenomenon of the head screws. Another patient experienced a periprosthetic femoral diaphysis fracture at the distal tip of the nail. A third patient experienced an acute postoperative superficial skin infection that was treated successfully with wound dressing changes and a course of antibiotics. Sixteen patients (22.2% deceased within 12 months postoperatively. In the remaining patients, the Harris Hip Score (HHS at 12 months postoperatively was excellent in 16 (28.6%, good in 23 (41.1%, fair in 10 (17.8%, and poor in 7 patients (12.5%. The function declined after the patients’ fracture. Fair and poor results were related to age > 85 years, poor pre-fracture level of function, and AO/OTA-31-A3 fracture types. Conclusion: The dual head screw intramedullary hip nail is associated with high healing and low complication rates for intertrochanteric fractures. The function of the patients is good or excellent in most cases; however, it declines, especially for those patients with age > 85 years, poor pre-fracture level of function, and AO/OTA-31-A3

  18. Delay differential equations for mode-locked semiconductor lasers.

    Science.gov (United States)

    Vladimirov, Andrei G; Turaev, Dmitry; Kozyreff, Gregory

    2004-06-01

    We propose a new model for passive mode locking that is a set of ordinary delay differential equations. We assume a ring-cavity geometry and Lorentzian spectral filtering of the pulses but do not use small gain and loss and weak saturation approximations. By means of a continuation method, we study mode-locking solutions and their stability. We find that stable mode locking can exist even when the nonlasing state between pulses becomes unstable.

  19. Visualization and understanding of the granulation liquid mixing and distribution during continuous twin screw granulation using NIR chemical imaging.

    Science.gov (United States)

    Vercruysse, Jurgen; Toiviainen, Maunu; Fonteyne, Margot; Helkimo, Niko; Ketolainen, Jarkko; Juuti, Mikko; Delaet, Urbain; Van Assche, Ivo; Remon, Jean Paul; Vervaet, Chris; De Beer, Thomas

    2014-04-01

    Over the last decade, there has been increased interest in the application of twin screw granulation as a continuous wet granulation technique for pharmaceutical drug formulations. However, the mixing of granulation liquid and powder material during the short residence time inside the screw chamber and the atypical particle size distribution (PSD) of granules produced by twin screw granulation is not yet fully understood. Therefore, this study aims at visualizing the granulation liquid mixing and distribution during continuous twin screw granulation using NIR chemical imaging. In first instance, the residence time of material inside the barrel was investigated as function of screw speed and moisture content followed by the visualization of the granulation liquid distribution as function of different formulation and process parameters (liquid feed rate, liquid addition method, screw configuration, moisture content and barrel filling degree). The link between moisture uniformity and granule size distributions was also studied. For residence time analysis, increased screw speed and lower moisture content resulted to a shorter mean residence time and narrower residence time distribution. Besides, the distribution of granulation liquid was more homogenous at higher moisture content and with more kneading zones on the granulator screws. After optimization of the screw configuration, a two-level full factorial experimental design was performed to evaluate the influence of moisture content, screw speed and powder feed rate on the mixing efficiency of the powder and liquid phase. From these results, it was concluded that only increasing the moisture content significantly improved the granulation liquid distribution. This study demonstrates that NIR chemical imaging is a fast and adequate measurement tool for allowing process visualization and hence for providing better process understanding of a continuous twin screw granulation system. Copyright © 2013 Elsevier B.V. All

  20. Gas flow through the clearances of screw spindle vacuum pumps; Gasspaltstroemungen in Schraubenspindel-Vakuumpumpen

    Energy Technology Data Exchange (ETDEWEB)

    Kauder, K.; Wenderott, D. [Dortmund Univ. (Germany). FG Fluidenergiemaschinen

    1998-12-31

    The documentation `Schraubenmaschinen` deals with the subject `screw spindle vacuum pump` for the first time. Therefore, this paper presents the type of maschine `screw spindle vacuum pump`, fixes its limits to the better known screw type compressor and finally classifies it in the crossover of vacuum-technology, characteristic geometry and the numerical simulation. The suggested reflections to choose a proper model of flow are based on the geometry of the screw spindle vacuum pump and fundamentals concerning the vacuum-technology and the state of flow. (orig.) [Deutsch] Die Schriftenreihe `Schraubenmaschinen` behandelt erstmals das Thema `Schraubenspindel-Vakuumpumpe`. Aus diesem Grund stellt der vorliegende Beitrag den Maschinentyp Schraubenspindel-Vakuumpumpe vor, grenzt ihn zur bekannteren Schraubenmaschine ab und ordnet ihn in der Schnittmenge aus Vakuumtechnik, charakteristischer Maschinengeometrie und der Simulation ein. Auf den vakuumtechnischen und stroemungstechnischen Grundlagen sowie geometrischen Betrachtungen basieren die genannten Ueberlegungen zur Auswahl geeigneter Stroemungsmodelle. (orig.)