  1. Unenhanced multidetector CT (CT KUB) in the initial imaging of suspected acute renal colic: evaluating a new service

    International Nuclear Information System (INIS)

    Chowdhury, F.U.; Kotwal, S.; Raghunathan, G.; Wah, T.M.; Joyce, A.; Irving, H.C.

    2007-01-01

    Aim: To evaluate a new imaging pathway for the investigation of patients presenting with suspected acute renal colic. Materials and methods: A retrospective review of 500 consecutive cases of suspected acute renal colic was undertaken to evaluate the initial results of a new imaging pathway introduced at our institution, which completely replaced the intravenous urogram (IVU) with unenhanced multidetector CT (CT KUB). Results: The positive rate for urolithiasis was 44% (221/500), the negative rate 46% (229/500) and the rate of other significant findings was 12% (59/500). Female patients had a low positive rate compared with male patients (27.5 versus 57.5%; p < 0.001). Urological intervention was required in 28% (61/221) and these patients had a larger average stone size (6.6 versus 3.7 mm; p < 0.001) and the stone was located more proximally. Out-of-hours imaging was performed in 37% (186/500), and these patients had a higher positive rate (52 versus 40%; p < 0.001). Other findings included a wide range of acute non-urological conditions. Conclusion: The feasibility of replacing the acute IVU with CT KUB in the initial assessment of suspected acute renal colic was demonstrated in the present study. The technique enables rapid diagnosis of urolithiasis, stratification of patients likely to proceed to urological intervention, and prompt diagnosis of a variety of other acute pathological conditions

  2. How accurate is unenhanced multidetector-row CT (MDCT) for localization of renal calculi?

    International Nuclear Information System (INIS)

    Goetschi, Stefan; Umbehr, Martin; Ullrich, Stephan; Glenck, Michael; Suter, Stefan; Weishaupt, Dominik

    2012-01-01

    Purpose: To investigate the correlation between unenhanced MDCT and intraoperative findings with regard to the exact anatomical location of renal calculi. Design, setting, and participants: Fifty-nine patients who underwent unenhanced MDCT for suspected urinary stone disease, and who underwent subsequent flexible ureterorenoscopy (URS) as treatment of nephrolithiasis were included in this retrospective study. All MDCT data sets were independently reviewed by three observers with different degrees of experience in reading CT. Each observer was asked to indicate presence and exact anatomical location of any calcification within pyelocaliceal system, renal papilla or renal cortex. Results were compared to intraoperative findings which have been defined as standard of reference. Calculi not described at surgery, but present on MDCT data were counted as renal cortex calcifications. Results: Overall 166 calculi in 59 kidneys have been detected on MDCT, 100 (60.2%) were located in the pyelocaliceal system and 66 (39.8%) in the renal parenchyma. Of the 100 pyelocaliceal calculi, 84 (84%) were correctly located on CT data sets by observer 1, 62 (62%) by observer 2, and 71 (71%) by observer 3. Sensitivity/specificity was 90–94% and 50–100% if only pyelocaliceal calculi measuring >4 mm in size were considered. For pyelocaliceal calculi ≤4 mm in size diagnostic performance of MDCT was inferior. Conclusion: Compared to flexible URS, unenhanced MDCT is accurate for distinction between pyelocaliceal calculi and renal parenchyma calcifications if renal calculi are >4 mm in size. For smaller renal calculi, unenhanced MDCT is less accurate and distinction between a pyelocaliceal calculus and renal parenchyma calcification is difficult.

  3. The value of unenhanced multi-detector computed tomography ...

    African Journals Online (AJOL)

    Introduction: Unenhanced computed tomography (CT) is used to detect urinary tract calculi with high accuracy. The development of multi-detector CT (MDCT) allows reconstructions in coronal, sagittal and oblique directions. Objective: To compare MDCT with three-dimensional (3D) ultrasound (US) imaging in evaluating ...

  4. Late Adverse Events after Enhanced and Unenhanced MRI and CT

    DEFF Research Database (Denmark)

    Azzouz, Manal; Rømsing, Janne; Thomsen, Henrik S.

    2014-01-01

    Prospective evaluation of frequency of late and very late adverse events in patients undergoing enhanced or unenhanced magnetic resonance imaging (MRI) or computed tomography (CT). The imaging procedure was performed according to the protocols of the department. All patients were contacted three...... of LAEs was significantly higher in the enhanced MRI (38%) and CT (27%) groups than unenhanced MRI (20%) and CT (16%) groups. The frequency of nausea, dizziness, abdominal pain and diarrhoea was significantly higher in the enhanced MRI group than in the MRI control group, while taste sensation...

  5. Unenhanced helical CT in the investigation of acute flank pain

    International Nuclear Information System (INIS)

    Colistro, Robert; Torreggiani, William C.; Lyburn, Iain D.; Harris, Alison C.; Al-Nakshabandi, Nizar A.; Nicolaou, Savvas; Munk, Peter L.

    2002-01-01

    Unenhanced helical CT has emerged as the imaging technique of choice for the investigation of patients presenting with acute flank pain and suspected nephroureteric stone disease. There are several signs identifiable on unenhanced CT that support a diagnosis of stone disease. However, there are many pitfalls, that may confound a correct diagnosis. Some of the common pitfalls, together with methods to avoid such occurrences, will be discussed. A review of some of the common alternative diagnoses that may mimic the symptoms of nephroureteric stone disease is illustrated. Colistro, R. et al (2002)

  6. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19,2016 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  7. Multidetector CT of the colon

    International Nuclear Information System (INIS)

    Luboldt, W.; Hoepffner, N.; Holzer, K.

    2003-01-01

    Multidetector technology, enabling faster imaging, higher spatial resolution and reduction in radiation dose, increases the role of CT in colonic diagnostic. The higher spatial resolution in the z-direction also changes the way to analyze the images. Instead of reading axial sections, now the colon can be systematically assessed in 3D by scrolling through multiplanar reconstructions or in CT colonography by virtual endoscopy. With ongoing improvements in computer-aided diagnosis CT colonography becomes an alternative to fiberoptic colonocopy for screening (http://www.multiorganscreening.org). In this article we propose a CT examination protocol for the colon, describe the typical imaging findings of different colonic diseases, and summarize the current status of CT colonography. (orig.)

  8. Right heart on multidetector CT

    Science.gov (United States)

    Gopalan, D

    2011-01-01

    Right ventricular function plays an integral role in the pathogenesis and outcome of many cardiovascular diseases. Imaging the right ventricle has long been a challenge because of its complex geometry. In recent years there has been a tremendous expansion in multidetector row CT (MDCT) and its cardiac applications. By judicious modification of contrast medium protocol, it is possible to achieve good opacification of the right-sided cardiac chambers, thereby paving the way for exploring the overshadowed right heart. This article will describe the key features of right heart anatomy, review MDCT acquisition techniques, elaborate the various morphological and functional information that can be obtained, and illustrate some important clinical conditions associated with an abnormal right heart. PMID:22723537

  9. Appendicitis and alternate diagnoses in children: findings on unenhanced limited helical CT

    International Nuclear Information System (INIS)

    Lowe, L.H.; Perez, R. Jr.; Scheker, L.E.; Stein, S.M.; Heller, R.M.; Hernanz-Schulman, M.

    2001-01-01

    The objective of this manuscript is to review and illustrate the findings of appendicitis, and of alternate diagnoses that may clinically or radiographically simulate appendicitis, on unenhanced limited CT in children. Potential pitfalls in unenhanced limited CT interpretation of pediatric patients will also be discussed. (orig.)

  10. Evaluation of anemia on unenhanced CT of the thorax

    International Nuclear Information System (INIS)

    Zhang Yuzhong; Zhang Xuelin; Zhong Qun; Zhang Fan; Zhang Wensheng

    2006-01-01

    Objective: To explore the correlation between CT density of blood in Cardiac Chambers and hemoglobin concentration in blood, and to evaluate the veracity of diagnosis of aneamia on unenhanced computed tomography of the thorax. Methods: Thorax (heart) helical CT was performed in 92 patients. In each case, the CT values of the blood pool in left ventricle and ventricular septum were tested, and the ratio of blood pool/ventricular septum were calculated. The hemoglobin concentration in blood was tested. The correlation among these indexes were analysed. Results: In these factors, CT density of blood was strongly and positively correlated with hemoglobin concentration in blood (r=0.571, P=0.000), and the CT density ratio was also strongly and positively correlated with hemoglobin concentration in blood (r=0.650, P=0.000). It dramatically implies that the patient may be suffering from aneamia when the ratio is Ness than 90% (male) or 87% (female). Conclusion: Blood pool/ventricular septum CT density ratio may be as a reliable indicator for judging and grading aneamia with CT. (authors)

  11. Detection of ingested cocaine-filled packets-Diagnostic value of unenhanced CT

    International Nuclear Information System (INIS)

    Schmidt, Sabine; Hugli, Olivier; Rizzo, Elena; Lepori, Domenico; Gudinchet, F.; Yersin, Bertrand; Schnyder, Pierre; Meuwly, Jean-Yves

    2008-01-01

    Purpose: Emergency departments are facing nowadays an increasing number of illegal drug-related health problems, associated with medicolegal and/or social consequences. Body stuffers are street cocaine dealers, who either store wrapped packets of drugs in their rectum or hastily swallow them, prompted by fear of police's arrest. These packets can be life threatening in case of leakage. We evaluate the diagnostic value of unenhanced multidetector CT (MDCT) for detection of cocaine-filled packets (CFP) ingested by body stuffers in a phantom model. Materials and methods: Our phantom simulated normal bowel contents in which a varying number of true and false CFP were randomly mixed. Both only differ in radiological density. During 18 different reading sessions, four radiologists independently evaluated the presence and number of true and false CFP. Interobserver agreement, sensitivity, specificity, positive and negative predictive value were calculated. Results: Interobserver agreement for detection of any packets, for visualization of true, and false CFP was good (κ = 0.63, 0.74 and 0.58, respectively). Sensitivity, specificity, positive and negative predictive value for detection of any packets was 95.6%, 100%, 100% and 62.5%, respectively; for visualization of the true CFP 86.5%, 100%, 100% and 77.6%, respectively; and for the false packets 98.1%, 65%, 88.6% and 87.5%, respectively. Conclusion: Unenhanced MDCT without bowel preparation is a fast, reliable and easily reproducible imaging modality for the immediate detection of ingested CFP, thus facilitating medicolegal management of body stuffers

  12. Spectral detector CT-derived virtual non-contrast images: comparison of attenuation values with unenhanced CT.

    Science.gov (United States)

    Ananthakrishnan, Lakshmi; Rajiah, Prabhakar; Ahn, Richard; Rassouli, Negin; Xi, Yin; Soesbe, Todd C; Lewis, Matthew A; Lenkinski, Robert E; Leyendecker, John R; Abbara, Suhny

    2017-03-01

    To assess virtual non-contrast (VNC) images obtained on a detection-based spectral detector CT scanner and determine how attenuation on VNC images derived from various phases of enhanced CT compare to those obtained from true unenhanced images. In this HIPAA compliant, IRB approved prospective multi-institutional study, 46 patients underwent pre- and post-contrast imaging on a prototype dual-layer spectral detector CT between October 2013 and November 2015, yielding 84 unenhanced and VNC pairs (25 arterial, 39 portal venous/nephrographic, 20 urographic). Mean attenuation was measured by one of three readers in the liver, spleen, kidneys, psoas muscle, abdominal aorta, and subcutaneous fat. Equivalence testing was used to determine if the mean difference between unenhanced and VNC attenuation was less than 5, 10, or 15 HU. VNC image quality was assessed on a 5 point scale. Mean difference between unenhanced and VNC attenuation was VNC attenuation were equivalent in all tissues except fat using a threshold of VNC overestimated the HU relative to unenhanced images. VNC image quality was rated as excellent or good in 84% of arterial phase and 85% of nephrographic phase cases, but only 40% of urographic phase. VNC images derived from novel dual layer spectral detector CT demonstrate attenuation values similar to unenhanced images in all tissues evaluated except for subcutaneous fat. Further study is needed to determine if attenuation thresholds currently used clinically for common pathology should be adjusted, particularly for lesions containing fat.

  13. Multidetector-row CT: economics and workflow

    International Nuclear Information System (INIS)

    Pottala, K.M.; Kalra, M.K.; Saini, S.; Ouellette, K.; Sahani, D.; Thrall, J.H.

    2005-01-01

    With rapid evolution of multidetector-row CT (MDCT) technology and applications, several factors such ad technology upgrade and turf battles for sharing cost and profitability affect MDCT workflow and economics. MDCT workflow optimization can enhance productivity and reduce unit costs as well as increase profitability, in spite of decrease in reimbursement rates. Strategies for workflow management include standardization, automation, and constant assessment of various steps involved in MDCT operations. In this review article, we describe issues related to MDCT economics and workflow. (orig.)

  14. Virtual unenhanced second generation dual-source CT of the liver: Is it time to discard the conventional unenhanced phase?

    International Nuclear Information System (INIS)

    Barrett, T.; Bowden, D.J.; Shaida, N.; Godfrey, E.M.; Taylor, A.; Lomas, D.J.; Shaw, A.S.

    2012-01-01

    Introduction: Dual-energy dual source CT can almost simultaneously image patients using two different tube potentials, allowing material decomposition and creation of ‘virtual unenhanced’ (VU) images from post-contrast series. Methods: 75 patients undergoing triple-phase liver CT examinations were imaged using a second generation dual-source CT machine with tube potentials 140/100 kVp. Post-processing VU series were derived from arterial and portal phases. Regions-of-interest from liver parenchyma and within fat (‘noise’ assessment) were drawn to compare VU series to conventional unenhanced (CU) series. Subjective analysis assessed image quality and the suitability of VU to replace CU series. Results: Mean Hounsfield unit (HU) values of liver were higher in the VU series: portal 51.9 (SD = 10.29), arterial 51.1 (SD = 10.05), compared to the CU series 49.2 (SD = 9.11); P < 0.001. However, Pearson's correlation of the VU and CU series remained excellent: 0.838 (portal), 0.831 (arterial). Bland–Altman plots also showed good agreement between both VU and the CU datasets. Noise measurements were significantly lower in both VU series (P < 0.001). For subjective analysis, image quality was rated as very good/excellent in 100% of CU images, 93.3% of portal VU and 88.7% of arterial VU series. Overall, portal VU and arterial VU images were acceptable replacements for the CU series in 97.4% and 96.1%, respectively. Post-processing was noted to create a number of artefacts in VU images – knowledge of these is essential for interpretation. Conclusions: Portal and arterial-derived VU images objectively correlate to CU images and demonstrate good image quality and acceptability. VU image sets could replace the conventional unenhanced images in the vast majority of cases, significantly reducing radiation dose.

  15. Multidetector computed tomography for the assessment of adnexal Mass: Is unenhenced CT scan necessary?

    International Nuclear Information System (INIS)

    Jung, Sung Il; Park, Hee Sun; Kim, Young Jun; Jeon, Hae Jeong

    2014-01-01

    To compare the diagnostic performance and radiation dose between contrast-enhanced CT (ECT) alone, and combined unenhanced and contrast-enhanced CT (UE + ECT) for the assessment of adnexal mass. This retrospective study was approved by the Institutional Review Board. A total of 146 consecutive patients (mean age, 41.1 years) who underwent preoperative unenhanced and contrast-enhanced multidetector CT of the pelvis and had adnexal masses found at surgery were included. Two readers independently evaluated the likelihood of adnexal malignancy on a 5-point scale on two different imaging datasets (ECT alone and UE + ECT). The area under the receiver operating characteristic curve (AUC) was used to evaluate diagnostic performance. Radiation dose to patients was calculated by the volume CT dose index (CTDIvol) and the dose length products (DLP) on each dataset. Of the total 178 adnexal masses, 133 masses were benign and 45 masses were malignant. For both readers, there is no significant difference of AUC values between ECT alone and UE + ECT for the detection of adnexal malignancy (reader 1, 0.93 vs. 0.95; reader 2, 0.92 vs. 0.91) (p > 0.05). The mean CTDIvol (12.6 ± 2.2 mGy) and DLP (641.2 ± 137.2 mGy) of ECT alone was significantly lower than the mean CTDIvol (21.5 ± 2.7 mGy) and DLP (923.6 ± 158.8 mGy) of UE + ECT (p < 0.0001). The use of unenhanced CT scan in addition to contrast-enhanced CT scan does not improve the detection of adnexal malignancy, but increases radiation exposure.

  16. Usefulness of unenhanced helical CT in patients with suspected ureteral colic

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Soo; Nam Kung, Sook; Kim, Heung Cheol; Hwang, Woo Chul; Lee, In Sun; Hwang, Im Kyung; Kim, Ho Chul; Bae, Sang Hoon; Lee, Sang Kon; Lee, Seong Ho [College of Medicine, Hallym Univ., Chunchon (Korea, Republic of)

    2002-07-01

    To determine the usefulness of unenhanced helical CT in patients with suspected renal colic. One hundred and fourteen patients with suspected ureteral colic, referred by physicians, underwent unenhanced helical CT. Two radiologists prospectively interpreted the results, determining the presence or absence of ureter stone and other diseases the arise outside the urinary tract. In cases of ureteral stone, we retrospectively sought secondary signs of hydronephrosis, perinephric fat stranding, thickening of renal fascia, renal enlargement, and the tissue rim sign. Among the 114 patients, 57 were confirmed as having ureter stones. Unenhanced helical CT depicted 57 of 58 stones in 57 patients, producing one false-negative and one false-positive result. Overall, the results showed 98% sensitivity, 95% specificity, 98% positive predictive value, 95% negative predictive value, and 97% accuracy. The frequencies of secondary signs were as follows: hydronephrosis, 95%(54/57); perinephric fat stranding, 81% (46/57); thickening of renal fascia, 77% (44/57); renal enlargement , 65%(37/57); and the tissure rim sign 72%(21/29). In 20 patients, the diagnoses were not related to stone disease and included one false-negative diagnosis of pyonephrosis. Unenhanced helical CT provides information which is valuable in the accurate diagnosis of ureteral stone as well as other diseases that arise outside the urinary tract in patients with suspected renal colic.

  17. Multidetector CT evaluation of potential right lobe living donors for ...

    African Journals Online (AJOL)

    Mohamed Saied Abdelgawad

    Multidetector CT evaluation of potential right lobe living donors for liver transplantation. Mohamed Saied Abdelgawad *, Osama L. El-Abd. National Liver Institute, El-Menoufiya University, Shebein El-Koom, Alexandria, Egypt. Received 4 June 2011; accepted 18 June 2011. KEYWORDS. Liver transplantation;. Multidetector ...

  18. Is CT effective in diagnosing the acute appendicitis?: Focus on comparison of unenhanced CT with barium enema

    International Nuclear Information System (INIS)

    Choi, Seong Hee; Hahm, So Hee; Kang Jin Hwa; Moon, Jeong Hwa

    1994-01-01

    To evaluate the role of unenhanced CT in diagnosing the acute appendicitis. We retrospectively analyzed conventional contrast-enhanced abdominal CT scans of 197 normal patients and barium enemas of 26 out of the 197 patients. Additional unenhanced CT scans of right lower abdomen were performed on 30 patients who were suspected of having acute appendicitis; barium enema was performed in 26 patients. In the analysis of the conventional CT scans, we could detect 132 (67%) normal appendices. On barium enema of 26 out of 197 patients, abruptly narrowed appendix was visualized in 5 cases and luminal irregularity in 4 cases but all 26 cases showed normal appendix on CT. In the 30 cases of unenhanced CT, all appendices were visualized. Among 12 cases which were proved as acute appendicitis, barium enema was done in 10 cases; abruptly narrowed appendix was shown in 3 and luminal irregularity in 1. Among 18 cases which were diagnosed as normal appendix, nonvisualization of appendix was in 1 case, abruptly narrowed lumen in 3, and luminal irregularity in 9. Unenhanced CT in the area of the cecum may be an effective and safe diagnostic tool acute appendicitis

  19. Systematic unenhanced CT for acute abdominal symptoms in the elderly patients improves both emergency department diagnosis and prompt clinical management

    International Nuclear Information System (INIS)

    Millet, Ingrid; Pages-Bouic, Emma; Curros-Doyon, Fernanda; Taourel, Patrice; Sebbane, Mustapha; Molinari, Nicolas; Riou, Bruno

    2017-01-01

    To assess the added-value of systematic unenhanced abdominal computed tomography (CT) on emergency department (ED) diagnosis and management accuracy compared to current practice, in elderly patients with non-traumatic acute abdominal symptoms. Institutional review board approval and informed consent were obtained. This prospective study included 401 consecutive patients 75 years of age or older, admitted to the ED with acute abdominal symptoms, and investigated by early systematic unenhanced abdominal CT scan. ED diagnosis and intended management before CT, after unenhanced CT, and after contrast CT if requested, were recorded. Diagnosis and management accuracies were evaluated and compared before CT (clinical strategy) and for two conditional strategies (current practice and systematic unenhanced CT). An expert clinical panel assigned a final diagnosis and management after a 3-month follow-up. Systematic unenhanced CT significantly improved the accurate diagnosis (76.8% to 85%, p=1.1 x 10 -6 ) and management (88.5% to 95.8%, p=2.6 x 10 -6 ) rates compared to current practice. It allowed diagnosing 30.3% of acute unsuspected pathologies, 3.4% of which were unexpected surgical procedure requirement. Systematic unenhanced abdominal CT improves ED diagnosis accuracy and appropriate management in elderly patients presenting with acute abdominal symptoms compared to current practice. (orig.)

  20. Systematic unenhanced CT for acute abdominal symptoms in the elderly patients improves both emergency department diagnosis and prompt clinical management

    Energy Technology Data Exchange (ETDEWEB)

    Millet, Ingrid; Pages-Bouic, Emma; Curros-Doyon, Fernanda; Taourel, Patrice [CHU Lapeyronie, Department of Medical Imaging, Montpellier Cedex 5 (France); Sebbane, Mustapha [Department of Emergency Medicine, CHU Lapeyronie, Montpellier (France); Molinari, Nicolas [Department of Medical Information and Statistics, CHU Montpellier (France); Riou, Bruno [GH Pitie-Salpetriere, APHP, Department of Emergency Medicine and Surgery, Paris (France)

    2017-02-15

    To assess the added-value of systematic unenhanced abdominal computed tomography (CT) on emergency department (ED) diagnosis and management accuracy compared to current practice, in elderly patients with non-traumatic acute abdominal symptoms. Institutional review board approval and informed consent were obtained. This prospective study included 401 consecutive patients 75 years of age or older, admitted to the ED with acute abdominal symptoms, and investigated by early systematic unenhanced abdominal CT scan. ED diagnosis and intended management before CT, after unenhanced CT, and after contrast CT if requested, were recorded. Diagnosis and management accuracies were evaluated and compared before CT (clinical strategy) and for two conditional strategies (current practice and systematic unenhanced CT). An expert clinical panel assigned a final diagnosis and management after a 3-month follow-up. Systematic unenhanced CT significantly improved the accurate diagnosis (76.8% to 85%, p=1.1 x 10{sup -6}) and management (88.5% to 95.8%, p=2.6 x 10{sup -6}) rates compared to current practice. It allowed diagnosing 30.3% of acute unsuspected pathologies, 3.4% of which were unexpected surgical procedure requirement. Systematic unenhanced abdominal CT improves ED diagnosis accuracy and appropriate management in elderly patients presenting with acute abdominal symptoms compared to current practice. (orig.)

  1. Multidetector CT portal venography in evaluation of portosystemic collateral vessels

    International Nuclear Information System (INIS)

    Agarwal, A.; Jain, M.

    2008-01-01

    This essay shows the usefulness of multidetector CT angiography for evaluation of the splenoportal venous system, which is essential in the management of patients with portal hypertension and its complications, such as portal vein thrombosis. By providing scanning with reconstruction of thin axial source images and reformatting into thicker multiplanar reformats, multidetector CT can help to determine the extent and location of portosystemic collateral vessels in patients with portal hypertension and is probably the optimal imaging technique in this setting.

  2. Comparison of virtual unenhanced CT images of the abdomen under different iodine flow rates.

    Science.gov (United States)

    Li, Yongrui; Li, Ye; Jackson, Alan; Li, Xiaodong; Huang, Ning; Guo, Chunjie; Zhang, Huimao

    2017-01-01

    To assess the effect of varying iodine flow rate (IFR) and iodine concentration on the quality of virtual unenhanced (VUE) images of the abdomen obtained with dual-energy CT. 94 subjects underwent unenhanced and triphasic contrast-enhanced CT scan of the abdomen, including arterial phase, portal venous phase, and delayed phase using dual-energy CT. Patients were randomized into 4 groups with different IFRs or iodine concentrations. VUE images were generated at 70 keV. The CT values, image noise, SNR and CNR of aorta, portal vein, liver, liver lesion, pancreatic parenchyma, spleen, erector spinae, and retroperitoneal fat were recorded. Dose-length product and effective dose for an examination with and without plain phase scan were calculated to assess the potential dose savings. Two radiologists independently assessed subjective image quality using a five-point scale. The Kolmogorov-Smirnov test was used first to test for normal distribution. Where data conformed to a normal distribution, analysis of variance was used to compare mean HU values, image noise, SNRs and CNRs for the 4 image sets. Where data distribution was not normal, a nonparametric test (Kruskal-Wallis test followed by stepwise step-down comparisons) was used. The significance level for all tests was 0.01 (two-sided) to allow for type 2 errors due to multiple testing. The CT numbers (HU) of VUE images showed no significant differences between the 4 groups (p > 0.05) or between different phases within the same group (p > 0.05). VUE images had equal or higher SNR and CNR than true unenhanced images. VUE images received equal or lower subjective image quality scores than unenhanced images but were of acceptable quality for diagnostic use. Calculated dose-length product and estimated dose showed that the use of VUE images in place of unenhanced images would be associated with a dose saving of 25%. VUE images can replace conventional unenhanced images. VUE images are not affected by varying iodine

  3. Acute ureterolithiasis: Incidence of secondary signs on unenhanced helical CT and influence on patient management

    Energy Technology Data Exchange (ETDEWEB)

    Ege, G. E-mail: gurkanege@yahoo.com; Akman, H.; Kuzucu, K.; Yildiz, S

    2003-12-01

    AIM: The purpose of this study was to determine the incidence of secondary signs associated with ureteral stones on unenhanced helical computed tomography (CT) of patients with acute renal colic, and to correlate these with patient management and outcome. MATERIALS AND METHODS: One hundred and ten patients with ureterolithiasis were evaluated prospectively for the secondary signs of obstruction on unenhanced helical CT. Our attention was focused primarily on the presence or absence of seven secondary signs on unenhanced helical CT, including hydronephrosis, unilateral renal enlargement, perinephric oedema, unilateral absence of the white pyramid, hydroureter, periureteral oedema and lateroconal fascial thickening. RESULTS: Of the 110 patients, 91 (82.7%) had hydroureter, 88 (80%) had hydronephrosis, 65 (59%) had periureteric oedema and 63 (57.2%) had unilateral renal enlargement. Ninety stones passed spontaneously and 21 required intervention. CONCLUSION: Secondary signs of urinary tract obstruction are useful and supportive findings in interpretation of the CT examination. In our experience, the most reliable signs indicating ureteral obstruction are hydroureter, hydronephrosis, periureteral oedema and unilateral renal enlargement, respectively. In addition, stones larger than 6 mm, located within the proximal two thirds of the ureter, and seen associated with five or more the secondary signs of obstruction, are more likely to require endoscopic removal and/or lithotripsy.

  4. Multidetector row computed tomography of acute pancreatitis: Utility of single portal phase CT scan in short-term follow up

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Yongwonn [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Park, Hee Sun, E-mail: heesun.park@gmail.com [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Kim, Young Jun; Jung, Sung Il; Jeon, Hae Jeong [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of)

    2012-08-15

    Objective: The purpose of this study is to evaluate the question of whether nonenhanced CT or contrast enhanced portal phase CT can replace multiphasic pancreas protocol CT in short term monitoring in patients with acute pancreatitis. Materials and methods: This retrospective study was approved by the Institutional Review Board. From April 2006 to May 2010, a total of 52 patients having acute pancreatitis who underwent initial dual phase multidetector row CT (unenhanced, arterial, and portal phase) at admission and a short term (within 30 days) follow up dual phase CT (mean interval 10.3 days, range 3-28 days) were included. Two abdominal radiologists performed an independent review of three sets of follow up CT images (nonenhanced scan, single portal phase scan, and dual phase scan). Interpretation of each image set was done with at least 2-week interval. Radiologists evaluated severity of acute pancreatitis with regard to pancreatic inflammation, pancreatic necrosis, and extrapancreatic complication, based on the modified CT severity index. Scores of each image set were compared using a paired t-test and interobserver agreement was evaluated using intraclass correlation coefficient statistics. Results: Mean scores of sum of CT severity index on nonenhanced scan, portal phase scan, and dual phase scan were 5.7, 6.6, and 6.5 for radiologist 1, and 5.0, 5.6, and 5.8 for radiologist 2, respectively. In both radiologists, contrast enhanced scan (portal phase scan and dual phase scan) showed significantly higher severity score compared with that of unenhanced scan (P < 0.05), while portal phase and dual phase scan showed no significant difference each other. The trend was similar regarding pancreatic inflammation and extrapancreatic complications, in which contrast enhanced scans showed significantly higher score compared with those of unenhanced scan, while no significant difference was observed between portal phase scan and dual phase scan. In pancreatic necrosis

  5. Distribution of Mitral Annular and Aortic Valve Calcium as Assessed by Unenhanced Multidetector Computed Tomography.

    Science.gov (United States)

    Koshkelashvili, Nikoloz; Codolosa, Jose N; Goykhman, Igor; Romero-Corral, Abel; Pressman, Gregg S

    2015-12-15

    Aging is associated with calcium deposits in various cardiovascular structures, but patterns of calcium deposition, if any, are unknown. In search of such patterns, we performed quantitative assessment of mitral annular calcium (MAC) and aortic valve calcium (AVC) in a broad clinical sample. Templates were created from gated computed tomography (CT) scans depicting the aortic valve cusps and mitral annular segments in relation to surrounding structures. These were then applied to CT reconstructions from ungated, clinically indicated CT scans of 318 subjects, aged ≥65 years. Calcium location was assigned using the templates and quantified by the Agatston method. Mean age was 76 ± 7.3 years; 48% were men and 58% were white. Whites had higher prevalence (p = 0.03) and density of AVC than blacks (p = 0.02), and a trend toward increased MAC (p = 0.06). Prevalence of AVC was similar between men and women, but AVC scores were higher in men (p = 0.008); this difference was entirely accounted for by whites. Within the aortic valve, the left cusp was more frequently calcified than the others. MAC was most common in the posterior mitral annulus, especially its middle (P2) segment. For the anterior mitral annulus, the medial (A3) segment calcified most often. In conclusion, AVC is more common in whites than blacks, and more intense in men, but only in whites. Furthermore, calcium deposits in the mitral annulus and aortic valve favor certain locations. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Is hepatotropic contrast enhanced MR a more effective method in differential diagnosis of hemangioma than multi-phase CT and unenhanced MR?

    Directory of Open Access Journals (Sweden)

    Markiet Karolina

    2011-04-01

    Full Text Available Abstract Background Cavernous hemangiomas are the most frequent neoplasms of the liver and in routine clinical practice they often need to be differentiated from malignant tumors and other benign focal lesions. The purpose of this study is to evaluate whether diagnostic accuracy of magnetic resonance imaging (MRI of hepatic hemangiomas, showing atypical pattern on US, improves with the use of Gd-BOPTA in comparison with contrast-enhanced multi-phase computed tomography (CT. Methods 178 consecutive patients with ambiguous hepatic masses showing atypical hyperechoic pattern on grey-scale US, underwent unenhanced and contrast-enhanced multi-phase multi-detector CT and MR (1.5T with the use of liver-specific contrast medium gadobenate dimeglumine (Gd-BOPTA. After intravenous contrast administration arterial (HAP, venous-portal (PVP, equilibrium phases (EP both in CT and MR and additionally hepatobiliary phase (HBP in MR were obtained. 398 lesions have been detected including 99 hemangiomas and 299 other lesions. Results In non-enhanced MDCT examination detection of hemangiomas was characterized by sensitivity of 76%, specificity of 90%, PPV of 71%, NPV of 92% and accuracy of 86%. Non-enhanced MR examination showed sensitivity of 98%, specificity of 99%, PPV of 99%, NPV of 99% and accuracy of 99%. After intravenous administration of contrast medium in MR the mentioned above parameters did not increase significantly. Conclusion Gd-BOPTA-enhanced MR in comparison with unenhanced MRI does not improve diagnostic accuracy in discriminating hemangiomas that show non-specific appearance in ultrasound examination. Unenhanced MR as a method of choice should directly follow US in course of diagnostic algorithm in differentiation of hemangiomas from other liver tumors.

  7. Multidetector CT angiography in Takayasu arteritis

    Energy Technology Data Exchange (ETDEWEB)

    Khandelwal, Niranjan; Kalra, Naveen [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Garg, Mandeep Kumar, E-mail: gargmandeep@hotmail.com [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Kang, Mandeep; Lal, Anupam [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Jain, Sanjay [Department of Internal Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Suri, Sudha [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India)

    2011-02-15

    Objective: To analyse the spectrum of Takayasu's arteritis (TA) on multidetector CT angiography (MDCTA). Materials and methods: A retrospective analysis of the MDCTA findings was performed on 15 patients clinically diagnosed as Takayasu's arteritis. The spectrum and incidence of imaging findings on CTA were compared to studies in literature on catheter angiography in Takayasu's arteritis. Laboratory parameters were available in nine patients. The disease was considered active if erythrocyte sedimentation rate (ESR) levels were elevated and 'C' reactive protein (CRP) was positive. An attempt was made to correlate disease activity with the imaging findings. Results: Ascending aorta, arch of aorta and descending thoracic aorta were involved in 14 out of 15 (93%) patients. The wall thickness varied between 1 and 10 mm with maximal involvement in arch and descending thoracic aorta. Major neck vessels were involved in 11 (73%) patients with most pronounced changes seen in the brachiocephalic trunk, left common carotid artery (CCA) and left subclavian artery (SCA). Abdominal aorta and its branches were involved in all the 11 (100%) patients in whom abdominal CTA was performed. Celiac axis and SMA were involved in 10 (91%) and seven (64%) patients, respectively while renal artery stenosis was present in five (45%) patients. In six patients, ESR was elevated and CRP was positive indicating active disease. All patients in whom the laboratory parameters were available showed mural thickening in the aorta and at least one of the neck vessels except for one patient with inactive disease who had aortic mural thickening only. Conclusion: MDCTA provides information about both the vessel wall and lumen in patients with Takayasu's disease.

  8. Multi-detector CT (MDCT in bowel and mesenteric injury

    Directory of Open Access Journals (Sweden)

    Vajjalla Ravikumar

    2013-04-01

    Full Text Available Objectives: To evaluate multi-detector CT (MDCT findings in bowel and mesenteric injury due to blunt abdominal trauma.Method: Retrospective evaluation of MDCT scan reports of patients admitted in Hamad Medical Corporation, Doha, Qatar with bowel and mesenteric injury during the period of January 2005 to April 2008.Results: MDCT, without using oral contrast, clearly demonstrated various specific and less specific findings of bowel and mesenteric injury.Conclusion: Multi-detector CT is an excellent diagnostic modality in bowel and mesenteric injury. Routine administration of oral contrast agent is not mandatory for initial evaluation of these patients.

  9. Is visual assessment of thyroid attenuation on unenhanced CT of the chest useful for detecting hypothyroidism?

    Science.gov (United States)

    Maldjian, P D; Chen, T

    2016-11-01

    To determine if visual assessment of the attenuation of morphologically normal appearing thyroid glands on unenhanced computed tomography (CT) of the chest is useful for identifying patients with decreased thyroid function. This was a retrospective study of 765 patients who underwent both unenhanced CT of the chest and thyroid function tests performed within 1 year of the CT examination. Attenuation of the thyroid gland was visually assessed in each patient relative to the attenuation of the surrounding muscles to categorise the gland as "low attenuation" (attenuation similar to surrounding muscles) or "high attenuation" (attenuation greater than surrounding muscles). Thyroid attenuation was quantitatively measured in each case to determine the validity of the visual assessment. Results of thyroid function tests were used to classify thyroid function as hypothyroid, euthyroid, or hyperthyroid. Data were analysed to determine the relationship between visual assessment of thyroid attenuation and status of thyroid function. Thyroid glands of low attenuation were present in 4.2% (32/765) of the patients. Nearly half (47%) of the patients with low-attenuation thyroids had hypofunctioning thyroid glands. Compared to patients with high-attenuation thyroids, patients with low-attenuation thyroids were significantly more likely to have decreased thyroid function (clinical and subclinical hypothyroidism) and significantly less likely to be euthyroid (p<0.0001). Quantitative measurement of thyroid attenuation confirmed the validity of the visual assessment. Low attenuation of an otherwise normal-appearing thyroid gland on unenhanced CT of the chest is strongly associated with decreased thyroid function. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  10. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  11. Multi-detector CT assessment of traumatic renal lesions

    African Journals Online (AJOL)

    Mohamed Samir Shaaban

    2015-07-10

    Jul 10, 2015 ... Aim of the work: To demonstrate different traumatic lesions of the kidneys using multi-detector. CT, and its use in ... sis and staging of renal trauma and guiding management. © 2015 The ... Emotion 6 (Siemens, Germany), and 16 detectors PHILIPS .... with active bleeding within the hematoma and was man-.

  12. Comparison of two imaging protocols for acute stroke: unenhanced cranial CT versus a multimodality cranial CT protocol with perfusion imaging

    International Nuclear Information System (INIS)

    Langer, R. D.; Gorkom, K. Neidl van.; Kaabi, Ho Al.; Torab, F.; Czechowski, J.; Nagi, M.; Ashish, G. M.

    2007-01-01

    Full text: The aim of the study was to validate a multimodality cranial computed tomography (CCT) protocol for patients with acute stroke in the United Arab Emirates as a basic imaging procedure for a stroke unit. Therefore, a comparative study was conducted between two groups: retrospective, historical group 1 with early unenhanced CCT and prospective group 2 undergoing a multimodality CCT protocol. Follow-up unenhanced CCT >48 h served as gold standard in both groups. Group 1: Early unenhanced CCT of 50 patients were evaluated retrospectively, using Alberta Stroke Program Early CT Score, and compared with the definite infarction on follow-up CCT. Group 2: 50 patients underwent multimodality CCT (unenhanced CCT, perfusion studies: cerebral blood flow, cerebral blood volume, mean transit time and CT angiography) <8 h after clinical onset and follow-up studies. Modified National Institute of Health Stroke Scale was used clinically in both groups. Group 1 showed 38 men, 12 women, clinical onset 2-8 h before CCT and modified National Institute of Health Stroke Scale 0-28. Group 2 included 38 men, 12 women, onset 3-8 h before CCT, modified National Institute of Health Stroke Scale 0-28. Sensitivity was 58.3% in group 1 and 84.2% in group 2. Computed tomography angiography detected nine intracranial occlusions/stenoses. The higher sensitivity of the multimodality CCT protocol justifies its use as a basic diagnostic tool for the set-up of a first-stroke unit in the United Arab Emirates

  13. Tuberculous Addison's disease: Morphological and quantitative evaluation with multidetector-row CT

    International Nuclear Information System (INIS)

    Ma Ensen; Yang Zhigang; Li Yuan; Guo Yingkun; Deng Yuping; Zhang Xiaochun

    2007-01-01

    Objective: To determine the characteristics of tuberculous Addison's disease on the axial and multiplanar reformatted (MPR) images of the multidetector-row computed tomography (MDCT). Materials and methods: The unenhanced and contrast-enhanced MDCT features in 19 patients with tuberculous Addison's disease were retrospectively assessed for the location, contour, size, calcification, attenuation, and enhancement patterns. The correlation between the duration of Addison's disease and the percentage of calcification presence was evaluated. Results: The adrenal glands were infected bilaterally in all of the 19 cases (100%, 38 glands). Enlargement of the glands appeared in 18 cases (94.7%, 36 glands) and the remaining one case (5.3%, two glands) showed atrophy bilaterally. Of the 36 enlarged adrenals, 13 (36.1%) had preserved contours, and the other 23 (63.9%) were mass-like. The size of the adrenals ranged from 0.6 to 4.8cm (mean 1.92+/-0.96cm). Calcification was revealed in 16 adrenals (16/38, 42.1%), increasing in incidence with disease progression. Fourteen of the 36 (38.9%) enlarged adrenals showed peripheral enhancement while the remaining 22 (61.1%) demonstrated heterogeneous enhancement. The ΔCT value, the attenuation measurement of mass-like lesions, was less in the central area (7+/-4HU) than that in the peripheral area (32+/-14HU) (P<0.01) between the unenhanced and contrast-enhanced scan. Conclusion: MDCT can reveal the characteristic morphology and CT attenuation in the tuberculous Addison's disease. Combined with its clinical presentations and biochemical findings, we can diagnose and stage adrenal tuberculosis with high specificity and accuracy on MDCT

  14. Multi-detector CT knee arthrography - initial experience

    International Nuclear Information System (INIS)

    Thomson, J.M.Z.; Fallon, M.; Breidahl, W.H.

    2002-01-01

    Full text: Traditional plain film arthrography can achieve reasonable accuracy and is an accepted method of investigation of patients with knee pain and possible meniscal tear. Multi-detector CT can potentially provide a more detailed and accurate examination due to its high-resolution crosssectional and multi-planar capabilities. The aim of this study was to assess the accuracy of our technique. All patients who underwent a multi-detector CT knee arthrogram in an initial 8 month period were identified. Initially the referring clinician was contacted. If the patient was referred to an orthopaedic surgeon the outcome of orthopaedic review was recorded using clinical, arthroscopic and / or MRI follow-up of the patient population. One hundred and twelve patients had a Multi-detector CT knee arthrogram performed within and 8 month period. Follow-up information was received in 69.7% of patients. Of these 68.9% had orthopaedic assessment - of which 69.2% underwent a knee arthroscopy.There was total agreement of findings in 67%, agreement of meniscal findings in 67% and chondral findings in 100%. Overall, orthopaedic opinion agreed with CT findings in 76.9%. At this stage, all meniscal tears not described in the initial CT arthrogram report have in retrospect been visible. Multi-detector CT knee arthrography is an accurate and elegant technique for investigation of knee pain, providing information in a format familiar to those reporting knee MRI. There is an initial learning curve. The technique is particularly useful in chondral assessment. It is accurate for meniscal pathology, although caution and recognition of potential pitfalls is required. Copyright (2002) Blackwell Science Pty Ltd

  15. Patent foramen ovale: detection with nongated multidetector CT.

    Science.gov (United States)

    Revel, Marie-Pierre; Faivre, Jean-Baptiste; Letourneau, Thierry; Henon, Hilde; Leys, Didier; Delannoy-Deken, Valérie; Remy-Jardin, Martine; Remy, Jacques

    2008-10-01

    To evaluate nongated multidetector computed tomography (CT) in the detection of patent foramen ovale (PFO) and atrial septal aneurysm (ASA) in comparison with transesophageal echocardiography (TEE). The study was approved by the institutional review board, and informed consent was obtained from all patients. One hundred five patients (57 men, 48 women; mean age, 53 years) with a recent stroke underwent TEE and multidetector CT on the same day. After injection of a diluted iodinated contrast material, a series of 2.4-mm-thick transverse images centered on the fossa ovalis were acquired in conjunction with release of the Valsalva maneuver. Two independent radiologists considered PFO present if left atrial enhancement was detected visually before enhancement of the pulmonary veins or if an early peak of left atrial enhancement was found at time-attenuation curve analysis. PFO was detected with 98% specificity (95% confidence interval [CI]: 0.91, 0.99). Overall sensitivity was 55% (95% CI: 0.38, 0.70), ranging from 28% for shunts classified as grade 1 at TEE to 91% for those classified as grade 4 at TEE. Interreader agreement was good (kappa = 0.81). Visual assessment was better than time-attenuation curve analysis, which enabled detection of only 15 of the 40 cases of PFO. Multidetector CT depicted only 22% of cases of ASA. The mean effective radiation dose was 2.3 mSv. Nongated multidetector CT can be used to diagnose high-grade shunts through a PFO, with 91% sensitivity and 98% specificity. Thus, PFO detection, in addition to routine CT evaluation of the lungs, could be indicated in patients with unexplained hypoxemia. (c) RSNA, 2008.

  16. Sacroiliitis in Ankylosing Spondylitis: Comparison with Multidetector Row CT and Plain Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ji Youn; Joo, Kyung Bin; Choi, Byeong Kyoo; Ryu, Jeong Ah; Kim, Tae Hwan; Choi, Woo Jung [Hanyang University Hospital, Seoul (Korea, Republic of)

    2009-03-15

    The objective of our study was to compare multidetector row CT and the plain radiographs for making the diagnosis and grading the sacroiliitis that accompanies ankylosing spondylitis. We wanted to determine the role of multidetector row CT for the evaluation of the sacroilitis in patients with ankylosing spondylitis. One hundred ninety two patients with clinically suspected ankylosing spondylitis were evaluated by conventional radiography and multidetector row CT. Two musculoskeletal radiologists retrospectively analyzed the images, and they graded the sacroiliitis using the modified New York Criteria. Multidetector row CT demonstrated a significantly higher sensitivity (74.5%, 83.3%) than did plain radiography (59.9%, 66.7%) for detecting early sacroiliitis (p<0.05). Multidetector row CT showed a higher grade of sacroiliitis in 114 and 127 of 384 sacroiliac joints. Performing multidetector row CT rather than plain radiography for making the diagnoses of accompanying ankylosing spondylitis allows an early start of treatment with a subsequently improved prognosis

  17. Multidetector CT evaluation of the postoperative pancreas.

    Science.gov (United States)

    Yamauchi, Fernando I; Ortega, Cinthia D; Blasbalg, Roberto; Rocha, Manoel S; Jukemura, José; Cerri, Giovanni G

    2012-01-01

    Several pancreatic diseases may require surgical treatment, with most of these procedures classified as resection or drainage. Resection procedures, which are usually performed to remove pancreatic tumors, include pancreatoduodenectomy, central pancreatectomy, distal pancreatectomy, and total pancreatectomy. Drainage procedures are usually performed to treat chronic pancreatitis after the failure of medical therapy and include the Puestow and Frey procedures. The type of surgery depends not only on the patient's symptoms and the location of the disease, but also on the expertise of the surgeon. Radiologists should become familiar with these surgical procedures to better understand postoperative changes in anatomic findings. Multidetector computed tomography is the modality of choice for identifying normal findings after surgery, postoperative complications, and tumor recurrence in patients who have undergone pancreatic surgery. RSNA, 2012

  18. ROLE OF MULTIDETECTOR CT IN EVALUATION OF NECK LESIONS

    Directory of Open Access Journals (Sweden)

    Reena Mathur

    2016-06-01

    Full Text Available AIMS AND OBJECTIVES To find out the role of multidetector computed tomography in the evaluation of neck lesions with respect to evaluation of the size, location and extent of tumour. Extension of tumour infiltrating into surrounding vascular and visceral structures. To correlate the findings of MD-CT with final diagnosis by biopsy. MATERIAL AND METHODS Data for the study was collected from patients with suspected neck lesions attending Department of Radio-diagnosis, J.L.N. Medical College and Associated Group of Hospitals, Ajmer, Rajasthan. A prospective study was conducted over a period (From 1st March 2014 to 31 Aug. 2015 on patients with clinically suspected neck lesions or patients who were diagnosed to have neck lesion on ultrasound and were referred to CT for further characterisation. The patients presented with symptoms of palpable neck mass and neck pain. Patients were evaluated using multidetector CT. A provisional diagnosis was made after CT scan and these findings were correlated with histopathology/surgical findings as applicable. RESULT In the present study, 97 out of 100 cases were correctly characterised by computed tomography giving an accuracy of 97%. One case of buccal carcinoma was wrongly diagnosed as benign lesion and another case of malignant lymph node was inaccurately diagnosed as benign lymph node, also another case of benign lymph node was inaccurately diagnosed as malignant lymph node. CONCLUSION Multidetector Computed Tomography of the neck has improved the localisation and characterisation of neck lesions. Accurate delineation of disease by CT scan provides a reliable preoperative diagnosis, plan for radiotherapy ports and posttreatment followup. However, histopathology still remains the gold standard as CT is not 100% accurate.

  19. Multidetector CT in children: current concepts and dose reduction strategies

    Energy Technology Data Exchange (ETDEWEB)

    Nievelstein, Rutger A.J.; Dam, Ingrid M. van [University Medical Centre Utrecht, Department of Pediatric Radiology, Wilhelmina Children' s Hospital, E01.132, P.O. Box 85500, Utrecht (Netherlands); Molen, Aart J. van der [Leiden University Medical Centre, Department of Radiology, C-2S, Leiden (Netherlands)

    2010-08-15

    The recent technical development of multidetector CT (MDCT) has contributed to a substantial increase in its diagnostic applications and accuracy in children. A major drawback of MDCT is the use of ionising radiation with the risk of inducing secondary cancer. Therefore, justification and optimisation of paediatric MDCT is of great importance in order to minimise these risks (''as low as reasonably achievable'' principle). This review will focus on all technical and non-technical aspects relevant for paediatric MDCT optimisation and includes guidelines for radiation dose level-based CT protocols. (orig.)

  20. Multidetector CT in children: current concepts and dose reduction strategies

    International Nuclear Information System (INIS)

    Nievelstein, Rutger A.J.; Dam, Ingrid M. van; Molen, Aart J. van der

    2010-01-01

    The recent technical development of multidetector CT (MDCT) has contributed to a substantial increase in its diagnostic applications and accuracy in children. A major drawback of MDCT is the use of ionising radiation with the risk of inducing secondary cancer. Therefore, justification and optimisation of paediatric MDCT is of great importance in order to minimise these risks (''as low as reasonably achievable'' principle). This review will focus on all technical and non-technical aspects relevant for paediatric MDCT optimisation and includes guidelines for radiation dose level-based CT protocols. (orig.)

  1. CT portography by multidetector helical CT. Comparison of three rendering models

    International Nuclear Information System (INIS)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki

    2002-01-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  2. CT portography by multidetector helical CT. Comparison of three rendering models

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki [Kumamoto Univ. (Japan). School of Medicine

    2002-12-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  3. Multidetector CT of blunt cervical spine trauma in adults.

    Science.gov (United States)

    Dreizin, David; Letzing, Michael; Sliker, Clint W; Chokshi, Falgun H; Bodanapally, Uttam; Mirvis, Stuart E; Quencer, Robert M; Munera, Felipe

    2014-01-01

    A number of new developments in cervical spine imaging have transpired since the introduction of 64-section computed tomographic (CT) scanners in 2004. An increasing body of evidence favors the use of multidetector CT as a stand-alone screening test for excluding cervical injuries in polytrauma patients with obtundation. A new grading scale that is based on CT and magnetic resonance (MR) imaging findings, the cervical spine Subaxial Injury Classification and Scoring (SLIC) system, is gaining acceptance among spine surgeons. Radiographic measurements described for the evaluation of craniocervical distraction injuries are now being reevaluated with the use of multidetector CT. Although most patients with blunt trauma are now treated nonsurgically, evolution in the understanding of spinal stability, as well as the development of new surgical techniques and hardware, has driven management strategies that are increasingly favorable toward surgical intervention. It is therefore essential that radiologists recognize findings that distinguish injuries with ligamentous instability or a high likelihood of nonfusion that require surgical stabilization from those that are classically stable and can be treated with a collar or halo vest alone. The purpose of this article is to review the spectrum of cervical spine injuries, from the craniocervical junction through the subaxial spine, and present the most widely used grading systems for each injury type. ©RSNA, 2014.

  4. Multidetector spiral CT arthrography of the shoulder

    Energy Technology Data Exchange (ETDEWEB)

    Lecouvet, Frederic E. [Departments of Radiology and Orthopaedic Surgery, Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Hippocrate Avenue 10/2942, 1200 Brussels (Belgium)], E-mail: frederic.lecouvet@uclouvain.be; Simoni, Paolo; Koutaissoff, Sophie; Vande Berg, Bruno C.; Malghem, Jacques; Dubuc, Jean-Emile [Departments of Radiology and Orthopaedic Surgery, Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Hippocrate Avenue 10/2942, 1200 Brussels (Belgium)

    2008-10-15

    Although MR imaging and MR arthrography are the first choice modalities for shoulder imaging, CT arthrography (CTA) may be used successfully to address many clinical questions. The advent of submillimeter multiple detector CT technology and subsequent excellent three-plane resolution has considerably increased the quality of CTA examinations and has propelled this technique to the forefront in a growing number of indications. The combined use of iodinated contrast material for fluoroscopic confirmation of the articular position of the needle before injection of gadolinium chelates for MR arthrography offers the unique opportunity to compare CTA and MRA findings in carefully selected cases. This paper illustrates capabilities and limits of CTA for the study of rotator cuff tears, shoulder instability, cartilage lesions, anatomical variants and abnormalities of the glenoid labrum, with correlations to MR arthrography and surgical findings.

  5. Multidetector spiral CT arthrography of the shoulder

    International Nuclear Information System (INIS)

    Lecouvet, Frederic E.; Simoni, Paolo; Koutaissoff, Sophie; Vande Berg, Bruno C.; Malghem, Jacques; Dubuc, Jean-Emile

    2008-01-01

    Although MR imaging and MR arthrography are the first choice modalities for shoulder imaging, CT arthrography (CTA) may be used successfully to address many clinical questions. The advent of submillimeter multiple detector CT technology and subsequent excellent three-plane resolution has considerably increased the quality of CTA examinations and has propelled this technique to the forefront in a growing number of indications. The combined use of iodinated contrast material for fluoroscopic confirmation of the articular position of the needle before injection of gadolinium chelates for MR arthrography offers the unique opportunity to compare CTA and MRA findings in carefully selected cases. This paper illustrates capabilities and limits of CTA for the study of rotator cuff tears, shoulder instability, cartilage lesions, anatomical variants and abnormalities of the glenoid labrum, with correlations to MR arthrography and surgical findings

  6. Pitfalls in multidetector row CT colonography

    International Nuclear Information System (INIS)

    Stoyneva, V.

    2009-01-01

    Full text:MDCT colonography is a reliable method for detection and identification of type of the colon lesions. At every step of the examination an error could be made and that would be lead to an incorrect diagnosis. Problems and pitfalls can be overcome with various useful techniques. The relatively clean and dry colon after careful preparation, allows avoiding problems of residual fluid and faeces. The knowledge about the structure and thickness characteristics of lesions of the colon and artefacts can to be useful in distinction of the polypoidal lesions from normal findings. The aim of this lecture is to describe common and less common pitfalls in CT colonography and to clarify features and CT criteria to distinction of organic formations from pseudo lesions. Inadequate preparation of the patient, weaknesses into the protocol, gaps and errors in interpretation are responsible for false positive and false negative results. The training which reduces the residual solids and liquid, marking, protocols elaboration and CAD allows achieving higher sensitivity and specificity. The 2D and 3D application techniques and solid knowledge about CT characteristic of the colon organic findings and pseudo lesions will reduce the rate of false positive results

  7. Coronal reconstruction of unenhanced abdominal CT for correct ureteral stone size classification

    Energy Technology Data Exchange (ETDEWEB)

    Berkovitz, Nadav; Simanovsky, Natalia; Hiller, Nurith [Hadassah Mount Scopus - Hebrew University Medical Center, Department of Radiology, Jerusalem (Israel); Katz, Ran [Hadassah Mount Scopus - Hebrew University Medical Center, Department of Urology, Jerusalem (Israel); Salama, Shaden [Hadassah Mount Scopus - Hebrew University Medical Center, Department of Emergency Medicine, Jerusalem (Israel)

    2010-05-15

    To determine whether size measurement of a urinary calculus in coronal reconstruction of computed tomography (CT) differs from stone size measured in the axial plane, and whether the difference alters clinical decision making. We retrospectively reviewed unenhanced CT examinations of 150 patients admitted to the emergency room (ER) with acute renal colic. Maximal ureteral calculus size was measured on axial slices and coronal reconstructions. Clinical significance was defined as an upgrading or downgrading of stone size according to accepted thresholds of treatment: {<=}5 mm, 6-9 mm and {>=}10 mm. There were 151 stones in 150 patients (male:female 115:34, mean age 41 years). Transverse stone diameters ranged from 1 to 11 mm (mean 4 mm). On coronal images, 56 (37%) stones were upgraded in severity; 46 (30%) from below 5 mm to 6 mm or more, and ten (7%) from 6-9 mm to 10 mm or more. Transverse measurement on the axial slices enabled correct categorization of 95 stones (63%). Transverse calculus measurement on axial slices often underestimates stone size and provides incorrect clinical classification of the true maximal stone diameter. Coronal reconstruction provides additional information in patients with renal colic that may alter treatment strategy. (orig.)

  8. Coronal reconstruction of unenhanced abdominal CT for correct ureteral stone size classification

    International Nuclear Information System (INIS)

    Berkovitz, Nadav; Simanovsky, Natalia; Hiller, Nurith; Katz, Ran; Salama, Shaden

    2010-01-01

    To determine whether size measurement of a urinary calculus in coronal reconstruction of computed tomography (CT) differs from stone size measured in the axial plane, and whether the difference alters clinical decision making. We retrospectively reviewed unenhanced CT examinations of 150 patients admitted to the emergency room (ER) with acute renal colic. Maximal ureteral calculus size was measured on axial slices and coronal reconstructions. Clinical significance was defined as an upgrading or downgrading of stone size according to accepted thresholds of treatment: ≤5 mm, 6-9 mm and ≥10 mm. There were 151 stones in 150 patients (male:female 115:34, mean age 41 years). Transverse stone diameters ranged from 1 to 11 mm (mean 4 mm). On coronal images, 56 (37%) stones were upgraded in severity; 46 (30%) from below 5 mm to 6 mm or more, and ten (7%) from 6-9 mm to 10 mm or more. Transverse measurement on the axial slices enabled correct categorization of 95 stones (63%). Transverse calculus measurement on axial slices often underestimates stone size and provides incorrect clinical classification of the true maximal stone diameter. Coronal reconstruction provides additional information in patients with renal colic that may alter treatment strategy. (orig.)

  9. Imaging of Acute Mesenteric Ischemia Using Multidetector CT and CT Angiography in a Porcine Model

    OpenAIRE

    Rosow, David E.; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S.; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I.; Mueller, Peter R.; Castillo, Carlos Fernández-del; Warshaw, Andrew L.; Thayer, Sarah P.

    2005-01-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly f...

  10. Multidetector row CT for imaging the paediatric tracheobronchial tree

    International Nuclear Information System (INIS)

    Papaioannou, Georgia; Young, Carolyn; Owens, Catherine M.

    2007-01-01

    The introduction of multidetector row computed tomography (MDCT) scanners has altered the approach to imaging the paediatric thorax. In an environment where the rapid acquisition of CT data allows general hospitals to image children instead of referring them to specialist paediatric centres, it is vital that general radiologists have access to protocols appropriate for paediatric applications. Thus a dramatic reduction in the delivered radiation dose is ensured with optimal contrast bolus delivery and timing, and inappropriate repetition of the scans is avoided. This article focuses on the main principles of volumetric CT imaging that apply generically to all MDCT scanners. We describe the reconstruction techniques for imaging the paediatric thorax and the low-dose protocols used in our institution on a 16-slice detector CT scanner. Examples of the commonest clinical applications are also given. (orig.)

  11. Imaging of pancreatic adenocarcinoma with emphasis on multidetector CT

    International Nuclear Information System (INIS)

    Smith, S.L.; Rajan, P.S.

    2004-01-01

    Pancreatic adenocarcinoma is the fourth most frequent cause of cancer-related death. The incidence is increasing and the overall survival has altered little in recent years. Moreover, patients usually present late with inoperable disease and curative resection by standard pancreatico-duodenectomy (Whipple's procedure) is associated with significant morbidity. It should only be attempted in that small group of patients lacking radiological evidence of advanced disease. Despite the recent advances in body magnetic resonance imaging (MRI) and endoscopic ultrasound (EUS), computed tomography (CT) is the mainstay of staging in most centres and the recent development of multidetector CT machines (MDCT) has raised hope of an improvement in preoperative staging. This review focuses on the CT of pancreatic adenocarcinoma with particular emphasis on examination technique and on those criteria that determine resectability

  12. Imaging of pancreatic adenocarcinoma with emphasis on multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.L. E-mail: simon.smith@ipsh-tr.anglox.nhs.uk; Rajan, P.S

    2004-01-01

    Pancreatic adenocarcinoma is the fourth most frequent cause of cancer-related death. The incidence is increasing and the overall survival has altered little in recent years. Moreover, patients usually present late with inoperable disease and curative resection by standard pancreatico-duodenectomy (Whipple's procedure) is associated with significant morbidity. It should only be attempted in that small group of patients lacking radiological evidence of advanced disease. Despite the recent advances in body magnetic resonance imaging (MRI) and endoscopic ultrasound (EUS), computed tomography (CT) is the mainstay of staging in most centres and the recent development of multidetector CT machines (MDCT) has raised hope of an improvement in preoperative staging. This review focuses on the CT of pancreatic adenocarcinoma with particular emphasis on examination technique and on those criteria that determine resectability.

  13. Pneumomediastinum on Multidetector CT: The Radiologic Signs and Underlying Disorders

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Soo Jin; Kim, Young Tong [Soonchunhyang University Chunan Hospital, Cheonan (Korea, Republic of)

    2011-02-15

    We can see the typical signs of pneumomediastinum on chest radiography and we can also see them on the multiplanar reformatted (MPR) image of multidetector CT (MDCT). MDCT can help to understand the anatomical feature of these signs and differentiate pneumomediastinum from pneumothorax, pneumopericardium and the Mach band effect. MDCT shows the peribronchovascular air, which reveals the Macklin effect, and it can also evaluate the underlying disorders that cause pneumomediastinum. The purpose of this pictorial essay is to inform physicians about the mechanism and anatomical features of pneumomediastinum, and to help them understand the imaging findings and underlying disorders of pneumomediastinum as seen on MDCT

  14. High density renal medulla on unenhanced CT : significance and relation with hydration status

    International Nuclear Information System (INIS)

    Lee, Eun Jung; Kim, Hyun Suk; Oh, Kyung Seung; Kim, Jong Min; Kim, Sung Min; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk

    1999-01-01

    To assess the effect of hydration status on renal medullary attenuation and to evaluate the incidence of dense renal medulla, as seen on unenhanced CT. We prospectively studied unenhanced CT scans of 12 healthy volunteers. Obtained done after 10 hours and 15 hours of dehydration and after oral intake of 2L of water. BUN/Cr, urine specific gravity, urine osmole and hematocrit were evaluated after 10 hours of dehydration. CT images were reviewed for the presence of dense renal medulla and differential attenuation of dense renal and isodense medulla and cortex at the same level. The density changes of renal medulla after hydration were evaluated. and CT findings were compared with the results of biochemical studies. In addition, we retrospectively reviewed the CT scans of 200 consecutive patients for evaluation of the incidence of dense renal medulla. In 8 of 12 volunteers, dense renal medulla was seen on CT scan after dehydration. Mean attenuation was 71.3±10.42HU after 10 hours of dehydration, 68.6±13.54HU after 15 hours, and 34.5±11.47HU after hydration. No significant attenuation differences were detected between 10 hours and 15 hours of dehydration, but significantly lower attenuation values were noted after hydration. For isodense medulla, the mean attenuation value was 35.7±7.9HU after 10 hours of dehydration, 39.58±9.66HU after 15 hours, and 36.58±7.77HU after hydration. The mean attenuation values of cortex were 35.9±5.95HU after 10 hours of dehydration. 37.58±5.95HU after 15 hours, and 37.08±9.75HU after hydration. With regard not only to duration of dehydration, but also ti hydration, no differences in attenuation values were noted for renal cortex or isodense renal medulla. However, higher density was noted in dense renal medulla than in isodense medulla or cortex for the same duration of dehydration. After hydration, complete resolution was seen at five of eight sites and incomplete resolution at three of eight sites. There was no correlation

  15. Comparison of CT numbers between cone-beam CT and multi-detector CT

    International Nuclear Information System (INIS)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, ρ(g/cm 3 ), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were ρ=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, ρ=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, ρ=0.001 H+1.43 with R2 value of 0.980 for i-CAT and ρ=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  16. Comparison of CT numbers between cone-beam CT and multi-detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-06-15

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, {rho}(g/cm{sup 3}), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were {rho}=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, {rho}=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, {rho}=0.001 H+1.43 with R2 value of 0.980 for i-CAT and {rho}=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  17. Multidetector CT findings of bowel Transection in blunt abdominal trauma

    International Nuclear Information System (INIS)

    Cho, Hyun Suk; Woo, Ji Young; Hong, Hye Suk; Park, Mee Hyun; Yang, Ik; Lee, Yul; Jung, Ah Young; Hwang, Ji Young; Ha, Hong Il

    2013-01-01

    Though a number of CT findings of bowel and mesenteric injuries in blunt abdominal trauma are described in literature, no studies on the specific CT signs of a transected bowel have been published. In the present study we describe the incidence and new CT signs of bowel transection in blunt abdominal trauma. We investigated the incidence of bowel transection in 513 patients admitted for blunt abdominal trauma who underwent multidetector CT (MDCT). The MDCT findings of 8 patients with a surgically proven complete bowel transection were assessed retrospectively. We report novel CT signs that are unique for transection, such as complete cutoff sign (transection of bowel loop), Janus sign (abnormal dual bowel wall enhancement, both increased and decreased), and fecal spillage. The incidence of bowel transection in blunt abdominal trauma was 1.56%. In eight cases of bowel transection, percentage of CT signs unique for bowel transection were as follows: complete cutoff in 8 (100%), Janus sign in 6 (100%, excluding duodenal injury), and fecal spillage in 2 (25%). The combination of complete cutoff and Janus sign were highly specific findings in patients with bowel transection. Complete cut off and Janus sign are the unique CT findings to help detect bowel transection in blunt abdominal trauma and recognition of these findings enables an accurate and prompt diagnosis for emergency laparotomy leading to reduced mortality and morbidity.

  18. Multidetector CT and MRI in diseases of the GI tract

    International Nuclear Information System (INIS)

    Bruel, J.M.; Gallix, B.

    2003-01-01

    With the introduction of spiral scanning then multidetector technologies, the accuracy for diagnosing digestive tract diseases with CT has been highly improved, and CT is used more and more in the evaluation of patients with suspected gastrointestinal disorders. CT is able to demonstrate both the intramural and the extra-mural components of the disease, and has a major role in the preoperative staging and the follow-up Improvements of CT protocols, such as CT-enteroclysis, or multiplanar 2D and 3D post-processing, including now techniques for 'virtual endoscopy', lead to discuss new indications in which CT could now compete with conventional X-rays series and video-endoscopy. This precise study of the digestive wall, the peri-digestive fat, the digestive tract blood supply, may be performed by MRI, under the condition of access to high level machines and standardized protocols. MR-enteroclysis and MR-virtual colonoscopy could be performed with much lower risk for the patient, in terms of radiation dose or contrast adverse effects. Endo-luminal coils should give to MR an ultra-high resolution for analysing the different layers of the gastrointestinal wall. Learning objectives: to review how to perform CT and MRI protocols for digestive tract imaging, to recognize the CT arid MR patterns of the main digestive tract diseases, to discuss the value, limits and role of CT and MR in digestive tract diseases, to discuss the potential role of CT and MR new technological developments for digestive tract imaging in the upcoming future Conclusion: CT is nowadays a modality of choice for digestive imaging. Improvements in technologies and indications, the necessary discussion of the risks and benefits for the patient should let the radiologists consider MRI in gastrointestinal disorders as an important part of the routine activity in clinical MRI. (authors)

  19. Likelihood of aneurysmal subarachnoid haemorrhage in patients with normal unenhanced CT, CSF xanthochromia on spectrophotometry and negative CT angiography.

    Science.gov (United States)

    Rana, A K; Turner, H E; Deans, K A

    2013-01-01

    Patients with suspected subarachnoid haemorrhage, a normal noncontrast computed tomography (CT) and cerebrospinal fluid (CSF) evidence of haemoglobin breakdown products often undergo CT angiography (CTA). If this is normal, then invasive catheter angiography may be offered. In current clinical practice, haemoglobin breakdown products are detected by spectrophotometry rather than visible xanthochromia, and CTA is performed on multidetector scanners. The aim of this study was to determine if such patients should still have a catheter angiography, given the associated risks. Patients positive for CSF spectrophotometry (n=26) were retrospectively identified from the clinical biochemistry information system and imaging data from the electronic radiology records were reviewed. Discharge letters were consulted to relate the biochemistry and radiology results to the final diagnosis. 15 patients with CT angiography were found. Nine patients had normal CT angiography. No causative aneurysms had been missed. One patient had small, coincidental aneurysms missed on initial reading of the CTA. The likelihood of a clinically significant aneurysm in a patient who is CT negative, lumbar puncture positive and CTA negative is low. Double reporting of negative CT angiograms may be advisable.

  20. Traumatic thoracic injury: the role of Multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Joo; Kang, Doo Kyung; Kim, Tae Hee [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2006-05-15

    The introduction of Multidetector-row CT (MDCT) has revolutionized the diagnostic strategy of multitrauma patients. The rapid acquisition of a large scanning volume with a thin slice collimation allows for motion-free images of high spatial resolution, and this enables the application of the multiplanar reformat (MPR) and 3D volume-rendering (VR) images. The MPR images more accurately demonstrate aortic rupture or dissection, diaphragmatic injuries and fracture of vertebrae, sternum and costal cartilages. Diagnosing vascular injuries can be aided by using the MIP images. Rib fracture, trachea and bronchial laceration are more easily detected by the 3D images, while airway and vascular injuries can be detected from performing virtual endoscopy. We introduce our current CT imaging protocol and we present our clinical experience with using MDCT in the assessment of patients with blunt thoracic trauma.

  1. Dual-energy CT of the brain: Comparison between DECT angiography-derived virtual unenhanced images and true unenhanced images in the detection of intracranial haemorrhage

    International Nuclear Information System (INIS)

    Bonatti, Matteo; Pernter, Patrizia; Bonatti, Giampietro; Lombardo, Fabio; Zamboni, Giulia A.; Pozzi Mucelli, Roberto

    2017-01-01

    To evaluate the diagnostic performance of virtual non-contrast (VNC) images in detecting intracranial haemorrhages (ICHs). Sixty-seven consecutive patients with and 67 without ICH who underwent unenhanced brain CT and DECT angiography were included. Two radiologists independently evaluated VNC and true non-contrast (TNC) images for ICH presence and type. Inter-observer agreement for VNC and TNC image evaluation was calculated. Sensitivity and specificity of VNC images for ICH detection were calculated using Fisher's exact test. VNC and TNC images were compared for ICH extent (qualitatively and quantitatively) and conspicuity assessment. On TNC images 116 different haemorrhages were detected in 67 patients. Inter-observer agreement ranged from 0.98-1.00 for TNC images and from 0.86-1.00 for VNC images. VNC sensitivity ranged from 0.90-1, according to the different ICH types, and specificity from 0.97-1. Qualitatively, ICH extent was underestimated on VNC images in 11.9% of cases. Haemorrhage volume did not show statistically significant differences between VNC and TNC images. Mean haemorrhage conspicuity was significantly lower on VNC images than on TNC images for both readers (p < 0.001). VNC images are accurate for ICH detection. Haemorrhages are less conspicuous on VNC images and their extent may be underestimated. (orig.)

  2. Dual-energy CT of the brain: Comparison between DECT angiography-derived virtual unenhanced images and true unenhanced images in the detection of intracranial haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Bonatti, Matteo; Pernter, Patrizia; Bonatti, Giampietro [Bolzano Central Hospital, Department of Radiology, Bolzano (Italy); Lombardo, Fabio; Zamboni, Giulia A.; Pozzi Mucelli, Roberto [University of Verona, Department of Radiology, Verona (Italy)

    2017-07-15

    To evaluate the diagnostic performance of virtual non-contrast (VNC) images in detecting intracranial haemorrhages (ICHs). Sixty-seven consecutive patients with and 67 without ICH who underwent unenhanced brain CT and DECT angiography were included. Two radiologists independently evaluated VNC and true non-contrast (TNC) images for ICH presence and type. Inter-observer agreement for VNC and TNC image evaluation was calculated. Sensitivity and specificity of VNC images for ICH detection were calculated using Fisher's exact test. VNC and TNC images were compared for ICH extent (qualitatively and quantitatively) and conspicuity assessment. On TNC images 116 different haemorrhages were detected in 67 patients. Inter-observer agreement ranged from 0.98-1.00 for TNC images and from 0.86-1.00 for VNC images. VNC sensitivity ranged from 0.90-1, according to the different ICH types, and specificity from 0.97-1. Qualitatively, ICH extent was underestimated on VNC images in 11.9% of cases. Haemorrhage volume did not show statistically significant differences between VNC and TNC images. Mean haemorrhage conspicuity was significantly lower on VNC images than on TNC images for both readers (p < 0.001). VNC images are accurate for ICH detection. Haemorrhages are less conspicuous on VNC images and their extent may be underestimated. (orig.)

  3. Cardiac causes of pulmonary arterial hypertension: assessment with multidetector CT

    International Nuclear Information System (INIS)

    Hoey, Edward T.D.; Gopalan, Deepa; Agrawal, S.K.B.; Screaton, Nicholas J.

    2009-01-01

    The causes of pulmonary arterial hypertension (PAH) are diverse and include multiple congenital and acquired cardiac diseases as well as diseases primarily affecting the pulmonary vasculature, lung, pleura and chest wall. The traditional role of CT in evaluating PAH includes assessment of pulmonary vasculature and lung parenchyma with limited assessment of the heart. Advances in multidetector CT technology with improved spatial and temporal resolution now permit accurate delineation of cardiac morphology. CT pulmonary angiography (CTPA) is widely utilised in the workup of patients with suspected pulmonary vascular disease and can identify both pulmonary and cardiac causes. As the initial presentation for CTPA is often precipitated by nonspecific, unexplained symptoms and therefore undertaken by a general radiologist, it is important that a systematic approach to the interpretation of these studies, including cardiac evaluation, is routinely adopted. This paper reviews the CT evaluation in pulmonary hypertension with a particular focus on the cardiac causes, their subclassification into congenital systemic to pulmonary shunts and secondary to left heart disease, and their imaging features. It emphasises the use of a systematic approach to interpretation of CTPA examinations both in patients with known PAH and those with previously unsuspected disease. (orig.)

  4. Cardiac causes of pulmonary arterial hypertension: assessment with multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Hoey, Edward T.D.; Gopalan, Deepa; Agrawal, S.K.B. [Papworth Hospital, Cambridge (United Kingdom); Screaton, Nicholas J. [Papworth Hospital, Cambridge (United Kingdom); Papworth Hospital NHS Trust, Diagnostic Centre, Department of Radiology, Papworth Everard, Cambridgeshire (United Kingdom)

    2009-11-15

    The causes of pulmonary arterial hypertension (PAH) are diverse and include multiple congenital and acquired cardiac diseases as well as diseases primarily affecting the pulmonary vasculature, lung, pleura and chest wall. The traditional role of CT in evaluating PAH includes assessment of pulmonary vasculature and lung parenchyma with limited assessment of the heart. Advances in multidetector CT technology with improved spatial and temporal resolution now permit accurate delineation of cardiac morphology. CT pulmonary angiography (CTPA) is widely utilised in the workup of patients with suspected pulmonary vascular disease and can identify both pulmonary and cardiac causes. As the initial presentation for CTPA is often precipitated by nonspecific, unexplained symptoms and therefore undertaken by a general radiologist, it is important that a systematic approach to the interpretation of these studies, including cardiac evaluation, is routinely adopted. This paper reviews the CT evaluation in pulmonary hypertension with a particular focus on the cardiac causes, their subclassification into congenital systemic to pulmonary shunts and secondary to left heart disease, and their imaging features. It emphasises the use of a systematic approach to interpretation of CTPA examinations both in patients with known PAH and those with previously unsuspected disease. (orig.)

  5. Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.

    Science.gov (United States)

    Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P

    2005-12-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.

  6. Cardiac Conduction System: Delineation of Anatomic Landmarks With Multidetector CT

    Directory of Open Access Journals (Sweden)

    Farhood Saremi

    2009-11-01

    Full Text Available Major components of the cardiac conduction system including the sinoatrial node (SAN, atrioventricular node (AVN, the His Bundle, and the right and left bundle branches are too small to be directly visualized by multidetector CT (MDCT given the limited spatial resolution of current scanners. However, the related anatomic landmarks and variants of this system a well as the areas with special interest to electrophysiologists can be reliably demonstrated by MDCT. Some of these structures and landmarks include the right SAN artery, right atrial cavotricuspid isthmus, Koch triangle, AVN artery, interatrial muscle bundles, and pulmonary veins. In addition, MDCT has an imperative role in demarcating potential arrhythmogenic structures. The aim of this review will be to assess the extent at which MDCT can outline the described anatomic landmarks and therefore provide crucial information used in clinical practice.

  7. Penetrating Colorectal Injuries: Diagnostic Performance of Multidetector CT with Trajectography.

    Science.gov (United States)

    Dreizin, David; Boscak, Alexis R; Anstadt, Michael J; Tirada, Nikki; Chiu, William C; Munera, Felipe; Bodanapally, Uttam K; Hornick, Michael; Stein, Deborah M

    2016-12-01

    Purpose To determine the diagnostic performance of multidetector computed tomography (CT) with trajectography for penetrating colorectal injuries. Materials and Methods This institutional review board-approved and HIPAA-compliant study was a 6-year blinded retrospective review by two independent readers of 182 consecutive patients who preoperatively underwent 40- or 64-row multidetector CT for penetrating torso trauma below the diaphragm and had surgically confirmed findings. Colorectal perforation was present in 42 patients. Trajectory analysis with postprocessing software was used for all studies. Additional signs evaluated were rectal contrast agent leak, collections of extruded fecal material, mural defect, wall thickening, abnormal enhancement, free fluid or stranding, and free air. The quality of the colorectal contrast agent administration was recorded. Sensitivity, specificity, predictive values, areas under the receiver operating characteristic curves (AUCs), and Cohen κ were determined. Results In patients with rectal contrast agent administration (n = 151), AUCs were 0.90-0.91, which indicated excellent accuracy. Trajectory was sensitive (88%-91%). For single wounds (n = 104), sensitivity of trajectory was 96% for both readers, but was only 80% for multiple wounds (n = 47). Contrast agent leak was highly specific (96%-98%), but insensitive (42%-46%). Improved diagnostic performance was observed in patients with poor colonic distension or opacification. Accuracy remained high (AUC, 0.86-0.99) in the group without rectal contrast agent administration (n = 31). Conclusion Trajectory had excellent sensitivity, while rectal contrast agent leak was specific but insensitive. Sensitivity of trajectory was lower for multiple wounds. Accuracy remained high in patients without rectal contrast agent administration. © RSNA, 2016.

  8. Imaging of patent foramen ovale with 64-section multidetector CT.

    Science.gov (United States)

    Saremi, Farhood; Channual, Stephanie; Raney, Aidan; Gurudevan, Swaminatha V; Narula, Jagat; Fowler, Steven; Abolhoda, Amir; Milliken, Jeffrey C

    2008-11-01

    To investigate the feasibility of 64-section multidetector computed tomography (CT) by using CT angiography (a) to demonstrate anatomic detail of the interatrial septum pertinent to the patent foramen ovale (PFO), and (b) to visually detect left-to-right PFO shunts and compare these findings in patients who also underwent transesophageal echocardiography (TEE). In this institutional review board-approved HIPAA-compliant study, electrocardiographically gated coronary CT angiograms in 264 patients (159 men, 105 women; mean age, 60 years) were reviewed for PFO morphologic features. The length and diameter of the opening of the PFO tunnel, presence of atrial septal aneurysm (ASA), and PFO shunts were evaluated. A left-to-right shunt was assigned a grade according to length of contrast agent jet (grade 1, 1 cm to 2 cm; grade 3, >2 cm). In addition, 23 patients who underwent both modalities were compared (Student t test and linear regression analysis). A difference with P patent at the entry into the right atrium (PFO) in 62 patients (61.4% of patients with flap valve, 23.5% of total patients). A left-to-right shunt was detected in 44 (16.7% of total) patients (grade 1, 61.4%; grade 2, 34.1%; grade 3, 4.5%). No shunt was seen in patients without a flap valve. Mean length of PFO tunnel was 7.1 mm in 44 patients with a shunt and 12.1 mm in 57 patients with a flap valve without a shunt (P < .0001). In patients with a tunnel length of 6 mm or shorter, 92.6% of the shunts were seen. ASA was seen in 11 (4.2%) patients; of these patients, a shunt was seen in seven (63.6%). In 23 patients who underwent CT angiography and TEE, both modalities showed a PFO shunt in seven. Multidetector CT provides detailed anatomic information about size, morphologic features, and shunt grade of the PFO. Shorter tunnel length and septal aneurysms are frequently associated with left-to-right shunts in patients with PFO. (c) RSNA, 2008.

  9. Breast multidetector-row CT with histopathologic correlation

    International Nuclear Information System (INIS)

    Takeuchi, Makiko; Yamashita, Akiyoshi; Ohgi, Kazuyuki; Kobori, Kenichi; Furukawa, Takashi

    2004-01-01

    The purpose of this study was to evaluate the correlation between multidetector-row CT (MDCT) and histopathologic findings using the same MDCT image as the histopathologic cross-section. MDCT with contrast enhancement was performed in 10 patients with breast cancers (8 invasive ductal carcinomas, one invasive lobular carcinoma, and one non-invasive ductal carcinoma). We tried to reconstruct multiplanar reconstructions (MPR) in the same plane as the histopathologic cross-section, and we evaluated the histopathologic findings of the false-positive lesions. In all cases, we obtained the same MDCT image as the histopathologic cross-section. There were 10 main lesions and 18 other lesions. In the other lesions, we found no false-negative lesions and 11 false-positive lesions. False-positive lesions included periductal fibrosis, cystic change, duct papillomatosis, sclerosing adenosis, fibroadenoma, and others. Using MDCT of the breast, it is possible to obtain good correlation between CT images and histopathologic findings. MDCT is thought to be useful in the evaluation CT findings on the basis of histopathologic evidence. (author)

  10. Trapping volumetric measurement by multidetector CT in chronic obstructive pulmonary disease: Effect of CT threshold

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaohua; Yuan, Huishu [Department of Radiology, Peking University Third Hospital, Beijing 100191 (China); Duan, Jianghui [Medical School, Peking University, Beijing 100191 (China); Du, Yipeng; Shen, Ning; He, Bei [Department of Respiration Internal Medicine, Peking University Third Hospital, Beijing 100191 (China)

    2013-08-15

    Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lung function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.

  11. Dual-energy CT of the brain: Comparison between DECT angiography-derived virtual unenhanced images and true unenhanced images in the detection of intracranial haemorrhage.

    Science.gov (United States)

    Bonatti, Matteo; Lombardo, Fabio; Zamboni, Giulia A; Pernter, Patrizia; Pozzi Mucelli, Roberto; Bonatti, Giampietro

    2017-07-01

    To evaluate the diagnostic performance of virtual non-contrast (VNC) images in detecting intracranial haemorrhages (ICHs). Sixty-seven consecutive patients with and 67 without ICH who underwent unenhanced brain CT and DECT angiography were included. Two radiologists independently evaluated VNC and true non-contrast (TNC) images for ICH presence and type. Inter-observer agreement for VNC and TNC image evaluation was calculated. Sensitivity and specificity of VNC images for ICH detection were calculated using Fisher's exact test. VNC and TNC images were compared for ICH extent (qualitatively and quantitatively) and conspicuity assessment. On TNC images 116 different haemorrhages were detected in 67 patients. Inter-observer agreement ranged from 0.98-1.00 for TNC images and from 0.86-1.00 for VNC images. VNC sensitivity ranged from 0.90-1, according to the different ICH types, and specificity from 0.97-1. Qualitatively, ICH extent was underestimated on VNC images in 11.9% of cases. Haemorrhage volume did not show statistically significant differences between VNC and TNC images. Mean haemorrhage conspicuity was significantly lower on VNC images than on TNC images for both readers (p < 0.001). VNC images are accurate for ICH detection. Haemorrhages are less conspicuous on VNC images and their extent may be underestimated. • VNC images represent a reproducible tool for detecting ICH. • ICH can be identified on VNC images with high sensitivity and specificity. • Intracranial haemorrhages are less conspicuous on VNC images than on TNC images. • Intracranial haemorrhages extent may be underestimated on VNC images.

  12. Prevalence of thoracolumbar vertebral fractures on multidetector CT

    International Nuclear Information System (INIS)

    Bartalena, Tommaso; Giannelli, Giovanni; Rinaldi, Maria Francesca; Rimondi, Eugenio; Rinaldi, Giovanni; Sverzellati, Nicola; Gavelli, Giampaolo

    2009-01-01

    Objective: To evaluate the prevalence of osteoporotic vertebral fractures in patients undergoing multidetector computed tomography (MDCT) of the chest and/or abdomen. Materials and methods: 323 consecutive patients (196 males, 127 females) with a mean age of 62.6 years (range 20-88) who had undergone chest and/or abdominal MDCT were evaluated. Sagittal reformats of the spine obtained from thin section datasets were reviewed by two radiologists and assessed for vertebral fractures. Morphometric analysis using electronic calipers was performed on vertebral bodies which appeared abnormal upon visual inspection. A vertebral body height loss of 15% or more was considered a fracture and graded as mild (15-24%), moderate (25-49%) or severe (more than 50%). Official radiology reports were reviewed and whether the vertebral fractures had been reported or not was noted. Results: 31 out of 323 patients (9.5%) had at least 1 vertebral fracture and 7 of those patients had multiple fractures for a total of 41 fractures. Morphometric grading revealed 10 mild, 16 moderate and 15 severe fractures. Prevalence was higher in women (14.1%) than men (6.6%) and increased with patients age with a 17.1% prevalence in post-menopausal women. Only 6 out 41 vertebral fractures (14.6%) had been noted in the radiology final report while the remaining 35 (85.45) had not. Conclusion: although vertebral fractures represent frequent incidental findings on multidetector CT studies and may be easily identified on sagittal reformats, they are often underreported by radiologists, most likely because of unawareness of their clinical importance.

  13. Recent technologic advances in multi-detector row cardiac CT.

    Science.gov (United States)

    Halliburton, Sandra Simon

    2009-11-01

    Recent technical advances in multi-detector row CT have resulted in lower radiation dose, improved temporal and spatial resolution, decreased scan time, and improved tissue differentiation. Lower radiation doses have resulted from the use of pre-patient z collimators, the availability of thin-slice axial data acquisition, the increased efficiency of ECG-based tube current modulation, and the implementation of iterative reconstruction algorithms. Faster gantry rotation and the simultaneous use of two x-ray sources have led to improvements in temporal resolution, and gains in spatial resolution have been achieved through application of the flying x-ray focal-spot technique in the z-direction. Shorter scan times have resulted from the design of detector arrays with increasing numbers of detector rows and through the simultaneous use of two x-ray sources to allow higher helical pitch. Some improvement in tissue differentiation has been achieved with dual energy CT. This article discusses these recent technical advances in detail.

  14. Diagnosis of arterial sequestration using multidetector CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Yu Hong, E-mail: yuhong.2002@hotmail.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China); Li Huimin, E-mail: lihuiminphd@163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China); Liu Shiyuan, E-mail: cjr.liushiyuan@vip.163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China); Xiao Xiangsheng, E-mail: cjr.xxsh@vip.163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China)

    2010-11-15

    Background: Arterial sequestration is a rare congenital disorder. The diagnostic evaluation of this condition using multidetector computerized tomography (MDCT) has not been described previously. The purpose of this study was to describe the characteristic features of this disorder and to assess the use of MDCT in visualizing the characteristic anatomic features. Methods: We retrospectively reviewed the records of seven patients with anomalous systemic blood supply to left lower lobe of the lung. All the patients had undergone MDCT angiography. To evaluate the lung parenchyma, bronchial branching pattern, and vascular anatomy, four series of images were systematically reconstructed as follows: contiguous transverse CT scans viewed at mediastinal and pulmonary window settings, oblique coronal and sagittal maximum intensity projections (MIP), multiplanar reconstruction (MPR), and three-dimensional volume-rendered images (VR) of airway and thoracic vascular structures. Results: All 7 cases had isolated and tortuous arterial anatomy from the descending thoracic aorta to the basal segment of the left lower lobe; however, variable distribution of branches was observed. Characteristic findings of anomalous systemic arterial (ASA) supply were distinct from those seen in other pulmonary sequestration syndromes and were well visualized by the use of noninvasive MDCT. Conclusion: Complex CT findings allow clear imaging of arterial sequestration and the ASA blood supply; MDCT angiography has demonstrated its value and accuracy in diagnosing this condition, obviating the use of digital subtraction angiography and magnetic resonance angiography for the diagnosis of arterial sequestration.

  15. Diagnosis of arterial sequestration using multidetector CT angiography

    International Nuclear Information System (INIS)

    Yu Hong; Li Huimin; Liu Shiyuan; Xiao Xiangsheng

    2010-01-01

    Background: Arterial sequestration is a rare congenital disorder. The diagnostic evaluation of this condition using multidetector computerized tomography (MDCT) has not been described previously. The purpose of this study was to describe the characteristic features of this disorder and to assess the use of MDCT in visualizing the characteristic anatomic features. Methods: We retrospectively reviewed the records of seven patients with anomalous systemic blood supply to left lower lobe of the lung. All the patients had undergone MDCT angiography. To evaluate the lung parenchyma, bronchial branching pattern, and vascular anatomy, four series of images were systematically reconstructed as follows: contiguous transverse CT scans viewed at mediastinal and pulmonary window settings, oblique coronal and sagittal maximum intensity projections (MIP), multiplanar reconstruction (MPR), and three-dimensional volume-rendered images (VR) of airway and thoracic vascular structures. Results: All 7 cases had isolated and tortuous arterial anatomy from the descending thoracic aorta to the basal segment of the left lower lobe; however, variable distribution of branches was observed. Characteristic findings of anomalous systemic arterial (ASA) supply were distinct from those seen in other pulmonary sequestration syndromes and were well visualized by the use of noninvasive MDCT. Conclusion: Complex CT findings allow clear imaging of arterial sequestration and the ASA blood supply; MDCT angiography has demonstrated its value and accuracy in diagnosing this condition, obviating the use of digital subtraction angiography and magnetic resonance angiography for the diagnosis of arterial sequestration.

  16. Accessory cardiac bronchus: Proposed imaging classification on multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kang Min; Kim, Young Tong; Han, Jong Kyu; Jou, Sung Shick [Dept. of Radiology, Soonchunhyang University College of Medicine, Cheonan Hospital, Cheonan (Korea, Republic of)

    2016-02-15

    To propose the classification of accessory cardiac bronchus (ACB) based on imaging using multidetector computed tomography (MDCT), and evaluate follow-up changes of ACB. This study included 58 patients diagnosed as ACB since 9 years, using MDCT. We analyzed the types, division locations and division directions of ACB, and also evaluated changes on follow-up. We identified two main types of ACB: blind-end (51.7%) and lobule (48.3%). The blind-end ACB was further classified into three subtypes: blunt (70%), pointy (23.3%) and saccular (6.7%). The lobule ACB was also further classified into three subtypes: complete (46.4%), incomplete (28.6%) and rudimentary (25%). Division location to the upper half bronchus intermedius (79.3%) and medial direction (60.3%) were the most common in all patients. The difference in division direction was statistically significant between the blind-end and lobule types (p = 0.019). Peribronchial soft tissue was found in five cases. One calcification case was identified in the lobule type. During follow-up, ACB had disappeared in two cases of the blind-end type and in one case of the rudimentary subtype. The proposed classification of ACB based on imaging, and the follow-up CT, helped us to understand the various imaging features of ACB.

  17. First experiences with multidetector CT in traumatized children

    International Nuclear Information System (INIS)

    Hoermann, Marcus; Scharitzer, Martina; Philipp, M.; Metz, Viktor M.; Lomoschitz, F.

    2003-01-01

    Introduction: The aim of this study was to describe and discuss first experiences with multidetector CT (MDCT) in the assessment of traumatized children. Material and methods: Since the implementation of a MDCT scanner in April 2002, 85 children (31 girls, 54 boys with a mean age of 9.2 years) consecutively underwent MDCT (Siemens, Erlangen, Germany) with different protocols depending on age, weight, trauma mechanism and clinical presentation. In all patients in whom pathology was suspected, multiplanar reformations (MPR) in coronal and or sagittal orientation was performed. Examinations were evaluated by two radiologists retrospectively and in consensus. Results: In 55 (65%) children, a MDCT solely of the head was performed, in 46 there was no pathology found. In six (7%), head and facial bones were scanned. Head and abdomen was examined in two (2%), in two (2%) the abdomen only and in one (1%) the pelvis solely. Scans of the spine were obtained in seven (8%) children. A thorax and abdomen examination only was obtained in one (1%) child each. In 11 (13%) children, a polytrauma protocol was performed. In all patients, the time of examination did not exceed 17 min, including setup time. All children survived at the writing of this report. Conclusion: MDCT was promising in the management of traumatized children and seems to shorten the necessary time to reach diagnosis and to initiate life-saving treatment

  18. First experiences with multidetector CT in traumatized children

    Energy Technology Data Exchange (ETDEWEB)

    Hoermann, Marcus E-mail: marcus.hoermann@univie.ac.at; Scharitzer, Martina; Philipp, M.; Metz, Viktor M.; Lomoschitz, F

    2003-10-01

    Introduction: The aim of this study was to describe and discuss first experiences with multidetector CT (MDCT) in the assessment of traumatized children. Material and methods: Since the implementation of a MDCT scanner in April 2002, 85 children (31 girls, 54 boys with a mean age of 9.2 years) consecutively underwent MDCT (Siemens, Erlangen, Germany) with different protocols depending on age, weight, trauma mechanism and clinical presentation. In all patients in whom pathology was suspected, multiplanar reformations (MPR) in coronal and or sagittal orientation was performed. Examinations were evaluated by two radiologists retrospectively and in consensus. Results: In 55 (65%) children, a MDCT solely of the head was performed, in 46 there was no pathology found. In six (7%), head and facial bones were scanned. Head and abdomen was examined in two (2%), in two (2%) the abdomen only and in one (1%) the pelvis solely. Scans of the spine were obtained in seven (8%) children. A thorax and abdomen examination only was obtained in one (1%) child each. In 11 (13%) children, a polytrauma protocol was performed. In all patients, the time of examination did not exceed 17 min, including setup time. All children survived at the writing of this report. Conclusion: MDCT was promising in the management of traumatized children and seems to shorten the necessary time to reach diagnosis and to initiate life-saving treatment.

  19. Coronary Vasospastic Angina: Assessment by Multidetector CT Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Koung Mi; Choi, Sang Il; Chun, Eun Ju; Kim, Jeong A; Youn, Tae Jin; Choi, Dong Ju [Seoul National University Bundang Hospital, Sungnam (Korea, Republic of)

    2012-01-15

    We aimed to describe the imaging findings of multidetector CT coronary angiography (MDCTA) in cases of vasospastic angina (VA) and to determine the accuracy of MDCTA in the identification of VA as compared with invasive coronary angiography with an ergonovine provocation test (CAG with an EG test). Fifty-three patients with clinically suspected VA were enrolled in this study. Two radiologists analyzed the stenosis degree, presence or absence of plaque, plaque composition, and a remodeling index of the related-segment in CAG with an EG test, which were used as a gold standard. We evaluated the diagnostic performances of MDCTA by comparing the MDCTA findings with those of CAG with an EG test. Among the 25 patients with positive CAG with an EG test, all 12 patients with significant stenosis showed no definite plaque with the negative arterial remodeling. Of the six patients with insignificant stenosis, three (50%) had non-calcified plaque (NCP), two (33%) had mixed plaque, and one (17%) had calcified plaque. When the criteria for significant stenosis with negative remodeling but no definite evidence of plaque as a characteristic finding of MDCTA were used, results showed sensitivities, specificities, positive predictive values (PPV), and negative predictive values (NPV) of 48%, 100%, 100%, and 68%, respectively. Significant stenosis with negative remodeling, but no definite evidence of plaque, is the characteristic finding on MDCTA of VA. Cardiac MDCTA shows good diagnostic performance with high specificity and PPV as compared with CAG with an EG test.

  20. Suspected ureteral colic: plain film and sonography vs unenhanced helical CT. A prospective study in 66 patients

    Energy Technology Data Exchange (ETDEWEB)

    Ripolles, Tomas; Agramunt, Marcos; Errando, Jose; Martinez, Maria Jesus [Department of Radiology, Hospital Universitario Dr. Peset, 90 Gaspar Aguilar Avenue, 46017, Valencia (Spain); Coronel, Belen [Department of Urology, Hospital Universitario Dr. Peset, 90 Gaspar Aguilar Avenue, 46017, Valencia (Spain); Morales, Maria [Research Unit, Hospital Universitario Dr. Peset, 90 Gaspar Aguilar Avenue, 46017, Valencia (Spain)

    2004-01-01

    The aim of this study was to compare the sensitivity and specificity of plain abdominal films plus ultrasound, vs nonenhanced CT for the diagnosis of ureteral colic in patients with acute flank pain. During a 4-month period, 66 patients (mean age 48 years) with acute flank pain were prospectively studied by means of plain abdominal film, US, and unenhanced CT. The presence of lithiasis and of obstructive uropathy signs were determined. The plain film was only used as a guide for the US exam. Clinical follow-up of all patients was obtained. Ureteral lithiasis was confirmed in 56 patients. The CT had a greater sensitivity (93 vs 79%) and negative predictive value (71 vs 46%) for the detection of lithiasis. The combination of lithiasis plus obstructive signs showed a sensitivity and a specificity of 100% for CT and of 100 and 90%, respectively, for US. The 11 lithiasis not detected by US were passed spontaneously (10 were <5 mm). Both techniques showed similar extraurinary pathology. Computed tomography is the most accurate technique for the detection of ureteral lithiasis; however, the combination of plain film and US is an alternative to nonenhanced CT with a lower sensitivity and radiation dose that has a good practical value. (orig.)

  1. The detectability of the origin of the inferior phrenic artery by paging method on multidetector-row CT angiography

    International Nuclear Information System (INIS)

    Terayama, Koshi

    2005-01-01

    We evaluated the ability to detect the origin of the inferior phrenic artery (IPA) by paging method on multidetector-row computed tomography (CT) angiography. In 104 patients who underwent multidetector-row CT, detectability of the origin of the IPA was assessed. In addition, in 30 patients in whom arteriographic study was performed, the IPA findings on multidetector-row CT were compared with those on arteriography. In 100 patients (96%) the origin of the right IPA was demonstrated with multidetector-row CT and in 93 patients (89%) the origin of the left IPA was demonstrated. CT angiographic findings concurred with arteriographic findings in all 30 patients (100%) who underwent arteriographic study. In conclusion, paging method on multidetector-row CT angiography provides valuable anatomical information regarding IPA. (author)

  2. Specificity of unenhanced CT for non-invasive diagnosis of hepatic steatosis: implications for the investigation of the natural history of incidental steatosis

    Energy Technology Data Exchange (ETDEWEB)

    Pickhardt, Perry J.; Hahn, Luke [University of Wisconsin School of Medicine and Public Health, Department of Radiology, Madison, WI (United States); Park, Seong Ho [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Lee, Sung-Gyu [University of Ulsan College of Medicine, Asan Medical Center, Division of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, Seoul (Korea, Republic of); Bae, Kyongtae T. [University of Pittsburgh, Department of Radiology, Pittsburgh, PA (United States); Yu, Eun Sil [University of Ulsan College of Medicine, Asan Medical Center, Department of Pathology, Seoul (Korea, Republic of)

    2012-05-15

    To determine a highly specific liver attenuation threshold at unenhanced CT for biopsy-proven moderate to severe hepatic steatosis ({>=}30% at histology). 315 asymptomatic adults (mean age {+-} SD, 31.5 {+-} 10.1 years; 207 men, 108 women) underwent same-day unenhanced liver CT and ultrasound-guided liver biopsy. Blinded to biopsy results, CT liver attenuation was measured using standard region-of-interest methodology. Multiple linear regression analysis was used to assess the relationship of CT liver attenuation with patient age, gender, BMI, CT system, and hepatic fat and iron content. Thirty-nine subjects had moderate to severe steatosis and 276 had mild or no steatosis. A liver attenuation threshold of 48 HU was 100% specific (276/276) for moderate to severe steatosis, with no false-positives. Sensitivity, PPV and NPV at this HU threshold was 53.8%, 100% and 93.9%. Hepatic fat content was the overwhelming determinant of liver attenuation values, but CT system (P < 0.001), and hepatic iron (P = 0.035) also had a statistically significant independent association. Unenhanced CT liver attenuation alone is highly specific for moderate to severe hepatic steatosis, allowing for confident non-invasive identification of large retrospective/prospective cohorts for natural history evaluation of incidental non-alcoholic fatty liver disease. Low sensitivity, however, precludes effective population screening at this threshold. (orig.)

  3. Specificity of unenhanced CT for non-invasive diagnosis of hepatic steatosis: implications for the investigation of the natural history of incidental steatosis

    International Nuclear Information System (INIS)

    Pickhardt, Perry J.; Hahn, Luke; Park, Seong Ho; Lee, Sung-Gyu; Bae, Kyongtae T.; Yu, Eun Sil

    2012-01-01

    To determine a highly specific liver attenuation threshold at unenhanced CT for biopsy-proven moderate to severe hepatic steatosis (≥30% at histology). 315 asymptomatic adults (mean age ± SD, 31.5 ± 10.1 years; 207 men, 108 women) underwent same-day unenhanced liver CT and ultrasound-guided liver biopsy. Blinded to biopsy results, CT liver attenuation was measured using standard region-of-interest methodology. Multiple linear regression analysis was used to assess the relationship of CT liver attenuation with patient age, gender, BMI, CT system, and hepatic fat and iron content. Thirty-nine subjects had moderate to severe steatosis and 276 had mild or no steatosis. A liver attenuation threshold of 48 HU was 100% specific (276/276) for moderate to severe steatosis, with no false-positives. Sensitivity, PPV and NPV at this HU threshold was 53.8%, 100% and 93.9%. Hepatic fat content was the overwhelming determinant of liver attenuation values, but CT system (P < 0.001), and hepatic iron (P = 0.035) also had a statistically significant independent association. Unenhanced CT liver attenuation alone is highly specific for moderate to severe hepatic steatosis, allowing for confident non-invasive identification of large retrospective/prospective cohorts for natural history evaluation of incidental non-alcoholic fatty liver disease. Low sensitivity, however, precludes effective population screening at this threshold. (orig.)

  4. Importance of multidetector CT imaging in multiple trauma

    International Nuclear Information System (INIS)

    Linsenmaier, U.; Geyer, L.L.; Reiser, M.; Wirth, S.; Koerner, M.

    2014-01-01

    Diagnostic imaging of complex multiple trauma remains a challenge for any department providing modern emergency radiology (ER) service. An early and comprehensive approach for ER imaging is crucial for a priority-oriented and timely therapy concept with the aim of identifying potentially life-threatening injuries early and initiating appropriate treatment. The basic diagnostic approach still consists of focused ultrasound using focused assessment with sonography for trauma (FAST) and conventional radiography (CR), usually limited to a single supine chest x-ray for triaging patients undergoing immediate operations. Multidetector computed tomography (MDCT) has become established as early whole body CT (WBCT) as the undisputable diagnostic method. The detection rate of injuries by WBCT is outstanding and it improves the probability of survival by 20-25 % compared with all other previous methods. At the same time, the spatial and temporal resolution of MDCT was improved resulting in considerably shortened examination times but WBCT is still associated with a significant radiation exposure, even in the acute single use setting. Using modern scanner and dose reduction technology, including iterative reconstruction, a dose reduction of up to 40 % could be achieved. The substantial number of images in WBCT is another challenge; images must be processed priority-oriented, read and transferred to the picture archiving and communications system (PACS). For rapid diagnosis, volume image reading (VIR) offers additional options to keep the diagnostic process on time. Modern WBCT after multiple trauma is performed early, comprehensively and personalized so that WBCT improves the probability of survival by 20-25 %. (orig.) [de

  5. Multi-Detector CT Findings of Palpable Chest Wall Masses in Children: A Pictorial Essay

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan Ho; Kim, Young Tong [Dept. of Radiology, Soonchunhyang University College of Medicine, Cheonan Hospital, Cheonan (Korea, Republic of); Hong, Hyun Sook [Dept. of Radiology, Soonchunhyang University College of Medicine, Bucheon Hospital, Bucheon (Korea, Republic of)

    2013-03-15

    A wide variety of diseases manifest as palpable chest wall masses in children. These include normal variation, congenital anomalies, trauma, infection, axillary lymphadenopathies, soft tissue tumors and bone tumors. Given that most of these diseases are associated with chest wall deformity, diagnosis is difficult by physical examination or ultrasonography alone. However, multi-detector CT with three dimensional reconstruction is useful in the characterization and differential diagnosis of palpable chest wall lesions. In this article, we review the spectrum of palpable chest wall diseases and illustrate their multi-detector CT presentation.

  6. Use of multidetector row CT with volume renderings in right lobe living liver transplantation

    International Nuclear Information System (INIS)

    Ishifuro, Minoru; Akiyama, Yuji; Kushima, Toshio; Horiguchi, Jun; Nakashige, Aya; Tamura, Akihisa; Marukawa, Kazushi; Fukuda, Hiroshi; Ono, Chiaki; Ito, Katsuhide

    2002-01-01

    Multidetector row CT is a feasible diagnostic tool in pre- and postoperative liver partial transplantation. We can assess vascular anatomy and liver parenchyma as well as volumetry, which provide useful information for both donor selection and surgical planning. Disorders of the vascular and biliary systems are carefully observed in recipients. In addition, we evaluate liver regeneration of both the donor and the recipient by serial volumetry. We present how multidetector row CT with state-of-the-art three-dimensional volume renderings may be used in right lobe liver transplantation. (orig.)

  7. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Rajaram, Smitha [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Academic Unit of Radiology, C Floor, Royal Hallamshire Hospital, Sheffield (United Kingdom); Swift, Andrew J.; Wild, Jim M. [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Capener, David; Telfer, Adam [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Davies, Christine; Hill, Catherine [Sheffield Teaching Hospitals Trust, Department of Radiology, Sheffield (United Kingdom); Condliffe, Robin; Elliot, Charles; Kiely, David G. [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Hurdman, Judith [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom)

    2012-02-15

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  8. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Rajaram, Smitha; Swift, Andrew J.; Wild, Jim M.; Capener, David; Telfer, Adam; Davies, Christine; Hill, Catherine; Condliffe, Robin; Elliot, Charles; Kiely, David G.; Hurdman, Judith

    2012-01-01

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  9. SU-E-P-49: Evaluation of Image Quality and Radiation Dose of Various Unenhanced Head CT Protocols

    International Nuclear Information System (INIS)

    Chen, L; Khan, M; Alapati, K; Hsieh, M; Barry, K

    2015-01-01

    Purpose: To evaluate the diagnostic value of various unenhanced head CT protocols and predicate acceptable radiation dose level for head CT exam. Methods: Our retrospective analysis included 3 groups, 20 patients per group, who underwent clinical routine unenhanced adult head CT examination. All exams were performed axially with 120 kVp. Three protocols, 380 mAs without iterative reconstruction and automAs, 340 mAs with iterative reconstruction without automAs, 340 mAs with iterative reconstruction and automAs, were applied on each group patients respectively. The images were reconstructed with H30, J30 for brain window and H60, J70 for bone window. Images acquired with three protocols were randomized and blindly reviewed by three radiologists. A 5 point scale was used to rate each exam The percentage of exam score above 3 and average scores of each protocol were calculated for each reviewer and tissue types. Results: For protocols without automAs, the average scores of bone window with iterative reconstruction were higher than those without iterative reconstruction for each reviewer although the radiation dose was 10 percentage lower. 100 percentage exams were scored 3 or higher and the average scores were above 4 for both brain and bone reconstructions. The CTDIvols are 64.4 and 57.8 mGy of 380 and 340 mAs, respectively. With automAs, the radiation dose varied with head size, resulting in 47.5 mGy average CTDIvol between 39.5 and 56.5 mGy. 93 and 98 percentage exams were scored great than 3 for brain and bone windows, respectively. The diagnostic confidence level and image quality of exams with AutomAs were less than those without AutomAs for each reviewer. Conclusion: According to these results, the mAs was reduced to 300 with automAs OFF for head CT exam. The radiation dose was 20 percentage lower than the original protocol and the CTDIvol was reduced to 51.2 mGy

  10. Evaluation of secondary spontaneous pneumothorax with multidetector CT

    International Nuclear Information System (INIS)

    Hilliard, N.J.; Marciniak, S.J.; Babar, J.L.; Balan, A.

    2013-01-01

    The purpose of this article is to review the underlying causes of secondary pneumothoraces as observed on multidetector computed tomography (MDCT). Using examples from our institutional experience, we shall illustrate important diagnostic features to indicate the underlying lung disease. Understanding the varied range of conditions is important for accurate diagnosis and facilitation of patient management

  11. Current status of multi-detector row helical CT in imaging of adult ...

    African Journals Online (AJOL)

    Current status of multi-detector row helical CT in imaging of adult acquired pancreatic diseases and assessing surgical neoplastic resectability. ... The presence of inflammation, masses, and vascular invasion was evaluated and interpreted images were obtained during each phase. Results were compared with surgery, ...

  12. Differentiation of Adrenal Adenoma and Nonadenoma in Unenhanced CT: New Optimal Threshold Value and the Usefulness of Size Criteria for Differentiation

    International Nuclear Information System (INIS)

    Park, Sung Hee; Kim, Myeong Jin; Kim, Joo Hee; Lim, Joon Seok; Kim, Ki Whang

    2007-01-01

    To determine the optimal threshold for the attenuation values in unenhanced computed tomography (CT) and assess the value of the size criteria for differentiating between an adrenal adenoma and a nonadenoma. The unenhanced CT images of 45 patients at our institution, who underwent a surgical resection of an adrenal masses between January 2001 and July 2005, were retrospectively reviewed. Forty-five adrenal masses included 25 cortical adenomas, 12 pheochromocytomas, three lymphomas, and five metastases confirmed by pathology were examined. The CT images were obtained at a slice thickness of 2 mm to 3 mm. The mAs were varied from 100 to 160 and 200 to 280, while the 120 KVp was maintained in all cases. The mean attenuation values of an adrenal adenoma and nonadenoma were compared using an unpaired t test. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy at thresholds of 10 HU, 20 HU, and 25 HU were compared. The diagnostic accuracy according to the size criteria from 2 cm to 6 cm was also compared. The twenty-five adenomas showed significantly lower (p 90% but a specificity < 70%. Size criteria of 2 or 3 cm had a high specificity of 100% and 80% but a low sensitivity of 20% and 60%. The threshold attenuation values of 20 or 25 HU in the unenhanced CT appear optimal for discriminating an adrenal adenoma from a nonadenoma. The size criteria are of little value in differentiating adrenal masses because of their low specificity or low sensitivity

  13. Hypervascular hepatocellular carcinomas: detection with gadoxetate disodium-enhanced MR imaging and multiphasic multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Hiromitsu; Kim, Tonsok; Hori, Masatoshi; Nakaya, Yasuhiro; Tsuboyama, Takahiro; Nakamoto, Atsushi; Tatsumi, Mitsuaki; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Radiology, Suita, Osaka (Japan); Imai, Yasuharu [Ikeda Municipal Hospital, Department of Gastroenterology, Ikeda, Osaka (Japan); Nagano, Hiroaki [Osaka University Graduate School of Medicine, Department of Surgery, Suita, Osaka (Japan); Kumano, Seishi; Okada, Masahiro; Murakami, Takamichi [Kinki University School of Medicine, Department of Radiology, Osakasayama, Osaka (Japan); Takamura, Manabu [Ikeda Municipal Hospital, Department of Radiology, Ikeda, Osaka (Japan); Wakasa, Kenichi [Osaka City University Graduate School of Medicine, Department of Diagnostic Pathology, Osaka, Osaka (Japan)

    2012-04-15

    To retrospectively compare the accuracy of detection of hypervascular hepatocellular carcinoma (HCC) by multiphasic multidetector CT and by gadoxetate disodium-enhanced MR imaging. After ethical approval, we analysed a total of 73 hypervascular HCC lesions from 31 patients suspected of having HCC, who underwent both gadoxetate disodium-enhanced MR imaging and multiphasic multidetector CT. Five blinded observers independently reviewed CT images, as well as dynamic MR images alone and combined with hepatobiliary phase MR images. Diagnostic accuracy (Az values), sensitivities and positive predictive values were compared by using the Scheffe post hoc test. The mean Az value for dynamic and hepatobiliary phase MR combined (0.81) or dynamic MR images alone (0.78) was significantly higher than that for CT images (0.67, P < 0.001, 0.005, respectively). The mean sensitivity of the combined MR images (0.67) was significantly higher than that of dynamic MR alone (0.52, P < 0.05) or CT images (0.44, P < 0.05). The mean positive predictive values were 0.96, 0.95 and 0.94, for CT, dynamic MR alone and combined MR images, respectively. Compared with multiphasic multidetector CT, gadoxetate disodium-enhanced MR imaging combining dynamic and hepatobiliary phase images results in significantly improved sensitivity and diagnostic accuracy for detection of hypervascular HCC. (orig.)

  14. Usefulness of percentage enhancement washout value calculated on unenhanced, contrast-enhanced, and delayed enhanced CT in adrenal masses: adenoma versus metastasis

    International Nuclear Information System (INIS)

    Sohn, Kyung Myung; Lee, Sung Yong; Lee, Keun Ho

    2003-01-01

    To determine the usefulness of percentage enhancement washout value calculated on unenhanced, enhanced and delayed enhanced CT scans for the characterization of adrenal masses. Forty adrenal masses less than 5 cm in size were assessed using a protocol consisting of unenhanced CT, enhanced CT 60 seconds after intravenous administration of contrast material, and delayed enhanced CT at 10 minutes. The CT attenuation value of adrenal tumors was estimated on each scan, and percentage enhancement washout value was calculated as follows:[(attenuation value at enhanced CT-attenuation value at delayed CT)/ (attenuation value at enhanced CT-attenuation value at unenhanced CT)x100]. An adrenal mass was considered benign if its percentage enhancement washout value was at the threshold value, set to 60% and 50%, or higher. The accuracy of the procedure was determined by comparing its findings with the final clinical diagnosis. Twenty-nine massess were benign and 11 were malignant. The mean percentage enhancement washout value of the former was significantly higher than that of the latter (66.7% vs. 21.8%; p<0.01). All adenomas except one had a washout value of more than 50%. With a percentage washout threshold of 60%, 35 of 40 lesions were correctly characterized as benign or malignant [sensitivity 82.7% (24/29), specificity 100% (11/11), accuracy 87.5% (35/40)]; with a threshold of 50%, 39 of 40 lesions were correctly characterized [(sensitivity 96.5% (28/29), specificity 100% (11/11), accuracy 97.5% (39/40)]. Percentage enhancement washout values are useful for characterizing an adrenal mass as benign or malignant. For characterization, a threshold value of 50% was more accurate than one of 60%

  15. Detection of intestinal bleeding with multi-detector row CT in an experimental setup. How many acquisitions are necessary?

    International Nuclear Information System (INIS)

    Dobritz, Martin; Engels, Heinz-Peter; Bauer, Jan; Rummeny, Ernst J.; Schneider, Armin

    2009-01-01

    The purpose of the study was to evaluate multi-detector computed tomography (MDCT) acquired in different acquisitions (unenhanced, and arterial and portal venous phase following intravenous contrast medium) for detection of intestinal bleeding using an experimental bowel model. The model consisted of an injector tube with a perforation placed in a 7-m-long small bowel of a pig. The bowel was filled with water/contrast medium solution of 30-40 HU and was incorporated in a phantom model. Intestinal bleeding in different locations and bleeding velocities varying from zero to 0.75 ml/min (0.05 ml/min increments) were simulated. Twenty-six datasets in simulated unenhanced, arterial and portal venous contrast phase using increasing bleeding velocities and ten negative controls were measured using 64-row MDCT. Two radiologists blinded to the experimental settings evaluated the datasets in a random order. The likelihood of intestinal bleeding was assessed using a 5-point scale with subsequent ROC analysis. The overall sensitivity for detecting bleeding was 0.44 for an arterial acquisition alone, 0.68 for a portal venous acquisition, 0.68 for the combination unenhanced/arterial, 0.72 for unenhanced/portal venous and 0.80 for arterial/portal. Bleeding velocities of above 0.25 ml/min were detected with a sensitivity of 0.59 for arterial, 0.88 for portal venous, 0.85 for unenhanced/arterial, 0.94 for unenhanced/portal venous and 0.97 for arterial/portal venous contrast phase protocols, respectively. The specificity was 1.00. MDCT provides the highest sensitivity and specificity in the detection of intestinal bleeding using arterial and portal venous acquisition in comparison to mono-phase protocols. (orig.)

  16. [Sigmoid endometriosis: a diagnostic dilemma on multidetector CT].

    Science.gov (United States)

    Telegrafo, Michele; Lorusso, Valentina; Rubini, Giuseppe; Rella, Leonarda; Pezzolla, Angela; Stabile Ianora, Amato Antonio; Moschetta, Marco

    2013-01-01

    Intestinal endometriosis represents a common condition that occurs particularly in women of reproductive age. The gastrointestinal tract is the third most common localization of endometriosis, after the ovaries and the peritoneum, and recto-sigmoid tract is involved in 70% of cases. Recto-sigmoid endometriosis has to be differentiated from other diseases of large bowel, especially in patients without a history of endometriosis. We report a case of sigmoid endometriosis which represented a diagnostic dilemma on multidetector computed tomography.

  17. Rheumatoid arthritis of the craniocervical region: assessment and characterization of inflammatory soft tissue proliferations with unenhanced and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Czerny, C.; Grampp, S.; Henk, C.B. [University Hospital Vienna (Austria). Dept. of Radiology; Neuhold, A. [Institute for Diagnostic Imaging, Hospital Rudolfinerhaus, Vienna (Austria); Stiskal, M. [Institute for Diagnostic Imaging, Hospital Lainz, Vienna (Austria); Smolen, J. [Department of Rheumatology, University Hospital Vienna (Austria)

    2000-09-01

    The aim of this study was to depict and characterize inflammatory soft tissue proliferations caused by rheumatoid arthritis (RA) in the craniocervical region by unenhanced and contrast-enhanced CT. Computed tomography of the craniocervical region was performed in 35 patients in the axial plane before and after the i. v. administration of contrast material. According to the densities and contrast enhancement of the inflammatory soft tissue proliferations, four groups were classified. Ancillary findings, such as a compression of the dural sac or spinal cord, erosions of the bony structures, and atlantoaxial subluxation, were also evaluated. Inflammatory soft tissue proliferations were depicted in 28 of 35 patients and could be differentiated by unenhanced and contrast-enhanced CT according to the above defined criteria: effusion in 6 patients (17 %); hypervascular pannus in 8 (23 %); hypovascular pannus in 5 (14 %); and fibrous tissue in 9 patients (26 %). A compression of the dural sac was seen in 11 (31 %) patients; 3 of these had neurological symptoms. Erosions of the odontoid process were found in 20 (57 %) patients; 16 (80 %) of these also showed erosions of the atlas. Atlantoaxial subluxation was seen in 11 (31 %) patients. Inflammatory soft tissue proliferations in the craniocervical region caused by RA can be reliably demonstrated and classified by unenhanced and contrast-enhanced CT, which can differentiate between joint effusion and various forms of pannus and depict ancillary findings. Computed tomography is an alternative method for patients unable to undergo an MRI examination. (orig.)

  18. Rheumatoid arthritis of the craniocervical region: assessment and characterization of inflammatory soft tissue proliferations with unenhanced and contrast-enhanced CT

    International Nuclear Information System (INIS)

    Czerny, C.; Grampp, S.; Henk, C.B.; Stiskal, M.; Smolen, J.

    2000-01-01

    The aim of this study was to depict and characterize inflammatory soft tissue proliferations caused by rheumatoid arthritis (RA) in the craniocervical region by unenhanced and contrast-enhanced CT. Computed tomography of the craniocervical region was performed in 35 patients in the axial plane before and after the i. v. administration of contrast material. According to the densities and contrast enhancement of the inflammatory soft tissue proliferations, four groups were classified. Ancillary findings, such as a compression of the dural sac or spinal cord, erosions of the bony structures, and atlantoaxial subluxation, were also evaluated. Inflammatory soft tissue proliferations were depicted in 28 of 35 patients and could be differentiated by unenhanced and contrast-enhanced CT according to the above defined criteria: effusion in 6 patients (17 %); hypervascular pannus in 8 (23 %); hypovascular pannus in 5 (14 %); and fibrous tissue in 9 patients (26 %). A compression of the dural sac was seen in 11 (31 %) patients; 3 of these had neurological symptoms. Erosions of the odontoid process were found in 20 (57 %) patients; 16 (80 %) of these also showed erosions of the atlas. Atlantoaxial subluxation was seen in 11 (31 %) patients. Inflammatory soft tissue proliferations in the craniocervical region caused by RA can be reliably demonstrated and classified by unenhanced and contrast-enhanced CT, which can differentiate between joint effusion and various forms of pannus and depict ancillary findings. Computed tomography is an alternative method for patients unable to undergo an MRI examination. (orig.)

  19. Multidetector helical CT plus superparamagnetic iron oxide-enhanced MR imaging for focal hepatic lesions in cirrhotic liver: A comparison with multi-phase CT during hepatic arteriography

    International Nuclear Information System (INIS)

    Yukisawa, Seigo; Okugawa, Hidehiro; Masuya, Yoshio; Okabe, Shinichirou; Fukuda, Hiroyuki; Yoshikawa, Masaharu; Ebara, Masaaki; Saisho, Hiromitsu

    2007-01-01

    The aim of this study was to evaluate multidetector helical computed tomography (MDCT), superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging, and CT arterial portography (CTAP) and CT during hepatic arteriography (CTHA) for the detection and diagnosis of hepatocellular carcinomas (HCC). This included visual correlations of MDCT and SPIO-MR imaging in the detection of HCC using receiver operating characteristic (ROC) analysis. Twenty-five patients with 57 nodular HCCs were retrospectively analyzed. A total of 200 segments, including 49 segments with 57 HCCs, were reviewed independently by three observers. Each observer read four sets of images (set 1, MDCT; set 2, unenhanced and SPIO-enhanced MR images; set 3, combined MDCT and SPIO-enhanced MR images; set 4, combined CTAP and CTHA). The mean Az values representing the diagnostic accuracy for HCCs of sets 1, 2, 3, and 4 were 0.777, 0.814, 0.849, and 0.911, respectively, and there was no significant difference between sets 3 and 4. The sensitivity of set 4 was significantly higher than those of set 3 for all the lesions and for lesions 10 mm or smaller (p < 0.05); however, for lesions larger than 10 mm, the sensitivities of the two sets were similar. No significant difference in positive predictive value and specificity was observed between set 3 and set 4. Combined MDCT and SPIO-enhanced MR imaging may obviate the need for more invasive CTAP and CTHA for the pre-therapeutic evaluation of patients with HCC more than 10 mm

  20. The role of unenhanced helical CT in the evaluation of suspected renal colic and atypical abdominal pain in children

    International Nuclear Information System (INIS)

    Eshed, Iris; Witzling, Michaela

    2002-01-01

    Background: Urolithiasis in children has a different pattern of presentation than in adults and its incidence is lower. Unenhanced helical CT (UEHCT) for suspected urinary tract calculi in adults has high sensitivity and specificity for detecting even minute calculi. UEHCT has been proposed as a fast and sensitive method for identifying urinary stones in children. However, to our knowledge, the role of UEHCT and its value in the diagnostic work-up of urinary stones in children has not been studied. Objective: To evaluate the significance of UEHCT as a diagnostic tool for urinary stones in children. Materials and methods: We retrospectively analysed data on 20 children who underwent UEHCT during 1999-2000. Results: Findings on UEHCT were significant in establishing a diagnosis in only seven patients and only three were shown to have urinary stones. Only one significant finding was found in the group who underwent UEHCT without prior US. US performed prior to UEHCT was a significant screening tool, and when results were equivocal, UEHCT further helped in establishing diagnosis. Conclusions: We propose that US be the first imaging modality in children with suspected urolithiasis. When the result of this examination is uncertain or abnormal, UEHCT will probably add further information which will contribute to the diagnosis. (orig.)

  1. Relationship between noise, dose, and pitch in cardiac multi-detector row CT.

    Science.gov (United States)

    Primak, Andrew N; McCollough, Cynthia H; Bruesewitz, Michael R; Zhang, Jie; Fletcher, Joel G

    2006-01-01

    In spiral computed tomography (CT), dose is always inversely proportional to pitch. However, the relationship between noise and pitch (and hence noise and dose) depends on the scanner type (single vs multi-detector row) and reconstruction mode (cardiac vs noncardiac). In single detector row spiral CT, noise is independent of pitch. Conversely, in noncardiac multi-detector row CT, noise depends on pitch because the spiral interpolation algorithm makes use of redundant data from different detector rows to decrease noise for pitch values less than 1 (and increase noise for pitch values > 1). However, in cardiac spiral CT, redundant data cannot be used because such data averaging would degrade the temporal resolution. Therefore, the behavior of noise versus pitch returns to the single detector row paradigm, with noise being independent of pitch. Consequently, since faster rotation times require lower pitch values in cardiac multi-detector row CT, dose is increased without a commensurate decrease in noise. Thus, the use of faster rotation times will improve temporal resolution, not alter noise, and increase dose. For a particular application, the higher dose resulting from faster rotation speeds should be justified by the clinical benefits of the improved temporal resolution. RSNA, 2006

  2. Multidetector-row CT duodenography in familial adenomatous polyposis: a pilot study

    International Nuclear Information System (INIS)

    Taylor, S.A.; Halligan, S.; Moore, L.; Saunders, B.P.; Gallagher, M.; Phillips, R.K.S.; Bartram, C.I.

    2004-01-01

    AIM: To investigate the feasibility of using multidetector-row computed tomography (CT) duodenography to stage duodenal polyposis in patients with familial adenomatous polyposis. MATERIALS AND METHODS: Six patients underwent multidetector-row CT duodenography before upper gastrointestinal endoscopy. A single-blinded radiologist used a surface shaded three-dimensional endoluminal fly though and two-dimensional axial and multiplanar reformats to assign a score for maximum polyp size and number based on the Spigelman classification. Comparison was made with the corresponding Spigelman scores obtained from subsequent endoscopy. RESULTS: CT duodenography was technically successful in five of six patients. The CT derived Spigelman score based on maximum polyp size was accurate in all five patients. The CT derived Spigelman score based on polyp number was accurate in only two cases: Polyp number was overestimated in one patient and underestimated in a further two. In retrospect, fine carpeting of tiny duodenal polyps was poorly visualized with CT. CONCLUSIONS: CT duodenography is technically feasible and accurately predicts maximum polyp size but CT estimates of polyp number are relatively inaccurate. CT duodenography potentially has a useful role for duodenal surveillance in those patients intolerant of conventional endoscopy

  3. Pulmonary nodules: sensitivity of maximum intensity projection versus that of volume rendering of 3D multidetector CT data

    NARCIS (Netherlands)

    Peloschek, Philipp; Sailer, Johannes; Weber, Michael; Herold, Christian J.; Prokop, Mathias; Schaefer-Prokop, Cornelia

    2007-01-01

    PURPOSE: To prospectively compare maximum intensity projection (MIP) and volume rendering (VR) of multidetector computed tomographic (CT) data for the detection of small intrapulmonary nodules. MATERIALS AND METHODS: This institutional review board-approved prospective study included 20 oncology

  4. The Utility of 64 Channel Multidetector CT Angiography for Evaluating the Renal Vascular Anatomy and Possible Variations: a Pictorial Essay

    International Nuclear Information System (INIS)

    Kumar, Sheo; Neyaz, Zafar; Gupta, Archna

    2010-01-01

    The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment

  5. The Utility of 64 Channel Multidetector CT Angiography for Evaluating the Renal Vascular Anatomy and Possible Variations: a Pictorial Essay

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Sheo; Neyaz, Zafar; Gupta, Archna [Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow (India)

    2010-06-15

    The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment.

  6. The utility of 64 channel multidetector CT angiography for evaluating the renal vascular anatomy and possible variations: a pictorial essay.

    Science.gov (United States)

    Kumar, Sheo; Neyaz, Zafar; Gupta, Archna

    2010-01-01

    The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment.

  7. Fluctuations in eGFR in relation to unenhanced and enhanced MRI and CT outpatients

    DEFF Research Database (Denmark)

    Azzouz, Manal; Rømsing, Janne; Thomsen, Henrik S

    2014-01-01

    OBJECTIVE: To study fluctuations in estimated glomerular filtration rate (eGFR) in relation to contrast medium (CM) enhanced magnetic resonance imaging (MRI) and computed tomography (CT) compared to control groups in outpatients. MATERIALS AND METHODS: eGFR was determined right before the imaging......-induced nephropathy (CIN) requirement when the definition s-creatinine ≥44μmol/l (0.5mg/dl) was used. CONCLUSIONS: eGFR in outpatients undergoing MRI or CT did vary independently of whether the patient received contrast or not. The findings probably reflect the natural variations in s-creatinine levels. This should...

  8. Multidetector CT (MD-CT) in the diagnosis of uncertain open globe injuries

    Energy Technology Data Exchange (ETDEWEB)

    Hoffstetter, P.; Schreyer, A.G.; Jung, E.M.; Heiss, P.; Zorger, N. [Inst. fuer Roentgendiagnostik, Universitaetsklinikum Regensburg (Germany); Schreyer, C.I.; Framme, C. [Klink und Poliklinik fuer Augenheilkunde, Universitaetsklinikum Regensburg (Germany)

    2010-02-15

    Purpose: To evaluate the significance of multislice CT for the diagnosis of uncertain penetrating globe injuries. Materials and Methods: Based on a retrospective chart review between 2002 and 2007, we identified 59 patients presenting with severe ocular trauma with uncertain rupture of the globe due to massive subconjunctival and/or anterior chamber hemorrhage. The IOP (intraocular pressure) was within normal range in all patients. High resolution multidetector CT (MD-CT) scans (16 slice scans) with axial and coronar reconstructions were performed in all patients. The affected eye was examined for signs of penetrating injury such as abnormal eye shape, scleral irregularities, lens dislocation or intravitreal hemorrhages. Four experienced radiologists read the CT scans independently. Beside the diagnosis, the relevant morphological criteria and the optimal plane orientation (axial or coronar) were specified. The sensitivity, specificity, and negative and positive predictive value were calculated. Additionally the interobserver variability was determined by applying the Cohen's kappa test. Surgical sclera inspections were performed in all cases as a standard of reference. The evaluations of the CT examination were compared with the surgery reports. Results: 59 patients were evaluated (42 men, 17 women). The mean age was 29 years (range 7-91). In 17 patients a rupture of the globe was diagnosed during surgery. 12 of these 17 penetrating injuries (70.6%) were classified correctly by MDCT, 5 of the 17 (29.4%) were not detectable. 42 patients did not have an open globe injury. 41 of these patients were diagnosed correctly negative by MDCT, and one patient was classified false positive. This results in a sensitivity of 70% with a specificity of 98%. There was high inter-rater agreement with kappa values between 0.89-0.96. Most discrepancies were caused by wrong negative findings. The most frequent morphologic criteria for open globe injury were the deformation (n

  9. Multidetector CT angiography of renal vasculature: normal anatomy and variants

    International Nuclear Information System (INIS)

    Tuerkvatan, Aysel; Oezdemir, Mustafa; Cumhur, Turhan; Oelcer, Tuelay

    2009-01-01

    Knowledge of the variations in renal vascular anatomy is important before laparoscopic donor or partial nephrectomy and vascular reconstruction for renal artery stenosis or abdominal aortic aneurysm. Recently, multidetector computed tomographic (MDCT) angiography has become a principal imaging investigation for assessment of the renal vasculature and has challenged the role of conventional angiography. It is an excellent imaging technique because it is a fast and non-invasive tool that provides highly accurate and detailed evaluation of normal renal vascular anatomy and variants. The number, size and course of the renal arteries and veins are easily identified by MDCT angiography. The purpose of this pictorial essay is to illustrate MDCT angiographic appearance of normal anatomy and common variants of the renal vasculature. (orig.)

  10. Multidetector CT angiography of renal vasculature: normal anatomy and variants

    Energy Technology Data Exchange (ETDEWEB)

    Tuerkvatan, Aysel; Oezdemir, Mustafa; Cumhur, Turhan; Oelcer, Tuelay [Tuerkiye Yueksek ihtisas Hospital, Department of Radiology, Sihhiye, Ankara (Turkey)

    2009-01-15

    Knowledge of the variations in renal vascular anatomy is important before laparoscopic donor or partial nephrectomy and vascular reconstruction for renal artery stenosis or abdominal aortic aneurysm. Recently, multidetector computed tomographic (MDCT) angiography has become a principal imaging investigation for assessment of the renal vasculature and has challenged the role of conventional angiography. It is an excellent imaging technique because it is a fast and non-invasive tool that provides highly accurate and detailed evaluation of normal renal vascular anatomy and variants. The number, size and course of the renal arteries and veins are easily identified by MDCT angiography. The purpose of this pictorial essay is to illustrate MDCT angiographic appearance of normal anatomy and common variants of the renal vasculature. (orig.)

  11. Multidetector CT of blunt traumatic venous injuries in the chest, abdomen, and pelvis.

    Science.gov (United States)

    Holly, Brian P; Steenburg, Scott D

    2011-01-01

    Venous injuries as a result of blunt trauma are rare. Even though current protocols for multidetector computed tomography (CT) of patients with trauma are designed to evaluate primarily the solid organs and arteries, blunt venous injuries may nevertheless be identified, or at least suspected, on the basis of the multidetector CT findings. Venous injuries are associated with high morbidity and mortality rates. Diagnosis of a possible venous injury is crucial because the physical findings of a venous injury are nonspecific and may be absent. This article aims to make the radiologist aware of various venous injuries caused by blunt trauma and to provide helpful hints to aid in the identification of venous injuries. Multidetector CT technology, in combination with interactive manipulation of the raw dataset, can be useful in the creation of multiplanar reconstructed images and in the identification of a venous injury caused by blunt trauma. Familiarity with direct and indirect signs of venous injuries, as well as with examples of blunt traumatic venous injuries in the chest, abdomen, and pelvis, will help in the diagnosis of these injuries.

  12. Congenital anomalies of coronary arteries: Diagnosis with 64 slice multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Tariq, Rukhsana, E-mail: drrukhsanatariq@hotmail.com [Consultant Radiologists, Advanced Radiology Clinic, Behind Hamdard University Hospital, Off M.A. Jinnah Road, Karachi (Pakistan); Kureshi, Shahzad Babar [Consultant Radiologists, Advanced Radiology Clinic, Behind Hamdard University Hospital, Off M.A. Jinnah Road, Karachi (Pakistan); Siddiqui, Usman T. [Medical College, Aga Khan University, Karachi (Pakistan); Ahmed, Rashid [Consultant Radiologists, Advanced Radiology Clinic, Behind Hamdard University Hospital, Off M.A. Jinnah Road, Karachi (Pakistan)

    2012-08-15

    Objective: Congenital coronary artery anomalies are generally incidental, uncommon and asymptomatic. Some can cause severe potentially life threatening symptoms. The common mode of studying the coronary arteries is Conventional Coronary Angiogram. ECG-gated-multidetector CT is a non invasive modality. The objective of our study was to identify rare congenital coronary artery anomalies and discuss their clinical significance. Material and methods: A total number of 900 MDCT coronary angiograms were carried out at our institution between the period of April 2006 and October 2010. Patients with coronary artery anomaly constituted the subject of study. Results: The incidence of anomalous anatomical origin and course of the coronary arteries in our study was 1.55%. Hemodynamical significance was seen in five patients. 3 cases of single coronary artery originating from right coronary sinus were seen. 1 case of anomalous left coronary artery arising from main pulmonary artery was seen. 4 cases of anomalous RCA arising from left aortic cusp, 6 cases of absent LMCA with separate origin of LAD and LCX were seen. Conclusion: Multidetector row CT is a noninvasive modality in cardiac imaging. It provides superior resolution of coronary tree and its variant. No projectional vascular overlap is seen. Various postprocessing techniques outclass catheter angiography imaging. Definition of ostia and proximal course of the coronary arteries by Multidetector CT is better than catheter angiography.

  13. Congenital anomalies of coronary arteries: Diagnosis with 64 slice multidetector CT

    International Nuclear Information System (INIS)

    Tariq, Rukhsana; Kureshi, Shahzad Babar; Siddiqui, Usman T.; Ahmed, Rashid

    2012-01-01

    Objective: Congenital coronary artery anomalies are generally incidental, uncommon and asymptomatic. Some can cause severe potentially life threatening symptoms. The common mode of studying the coronary arteries is Conventional Coronary Angiogram. ECG-gated-multidetector CT is a non invasive modality. The objective of our study was to identify rare congenital coronary artery anomalies and discuss their clinical significance. Material and methods: A total number of 900 MDCT coronary angiograms were carried out at our institution between the period of April 2006 and October 2010. Patients with coronary artery anomaly constituted the subject of study. Results: The incidence of anomalous anatomical origin and course of the coronary arteries in our study was 1.55%. Hemodynamical significance was seen in five patients. 3 cases of single coronary artery originating from right coronary sinus were seen. 1 case of anomalous left coronary artery arising from main pulmonary artery was seen. 4 cases of anomalous RCA arising from left aortic cusp, 6 cases of absent LMCA with separate origin of LAD and LCX were seen. Conclusion: Multidetector row CT is a noninvasive modality in cardiac imaging. It provides superior resolution of coronary tree and its variant. No projectional vascular overlap is seen. Various postprocessing techniques outclass catheter angiography imaging. Definition of ostia and proximal course of the coronary arteries by Multidetector CT is better than catheter angiography.

  14. Fluctuations in eGFR in relation to unenhanced and enhanced MRI and CT outpatients

    Energy Technology Data Exchange (ETDEWEB)

    Azzouz, Manal, E-mail: manalazzouz@gmail.com [Department of Diagnostic Radiology, Copenhagen University Hospital Herlev, Herlev Ringvej 75, DK 2730 Herlev (Denmark); Rømsing, Janne [Department of Drug Design and Pharmacology, University of Copenhagen, Universitetsparken 2, DK-2100 Copenhagen Ø (Denmark); Thomsen, Henrik S. [Department of Diagnostic Radiology, Copenhagen University Hospital Herlev, Herlev Ringvej 75, DK 2730 Herlev (Denmark)

    2014-06-15

    Objective: To study fluctuations in estimated glomerular filtration rate (eGFR) in relation to contrast medium (CM) enhanced magnetic resonance imaging (MRI) and computed tomography (CT) compared to control groups in outpatients. Materials and methods: eGFR was determined right before the imaging procedure and three days later at the department or at the patient's home. The iodine-based and gadolinium-based contrast media were the same as used for all other examinations at the department. Results: A total of 716 patients completed the study. There was a statistically significant, but not clinically relevant rise in eGFR after three days in all four groups. The average eGFR variation was 4.8 ml/min/1.73 m{sup 2}. There were large variations in eGFR between the two measurements in 45.8% of the patients as they had a change greater than ±10 ml/min/1.73 m{sup 2}. Only three patients fulfilled the contrast-induced nephropathy (CIN) requirement when the definition s-creatinine ≥44 μmol/l (0.5 mg/dl) was used. Conclusions: eGFR in outpatients undergoing MRI or CT did vary independently of whether the patient received contrast or not. The findings probably reflect the natural variations in s-creatinine levels. This should be taken into consideration when CIN is studied.

  15. Fluctuations in eGFR in relation to unenhanced and enhanced MRI and CT outpatients

    International Nuclear Information System (INIS)

    Azzouz, Manal; Rømsing, Janne; Thomsen, Henrik S.

    2014-01-01

    Objective: To study fluctuations in estimated glomerular filtration rate (eGFR) in relation to contrast medium (CM) enhanced magnetic resonance imaging (MRI) and computed tomography (CT) compared to control groups in outpatients. Materials and methods: eGFR was determined right before the imaging procedure and three days later at the department or at the patient's home. The iodine-based and gadolinium-based contrast media were the same as used for all other examinations at the department. Results: A total of 716 patients completed the study. There was a statistically significant, but not clinically relevant rise in eGFR after three days in all four groups. The average eGFR variation was 4.8 ml/min/1.73 m 2 . There were large variations in eGFR between the two measurements in 45.8% of the patients as they had a change greater than ±10 ml/min/1.73 m 2 . Only three patients fulfilled the contrast-induced nephropathy (CIN) requirement when the definition s-creatinine ≥44 μmol/l (0.5 mg/dl) was used. Conclusions: eGFR in outpatients undergoing MRI or CT did vary independently of whether the patient received contrast or not. The findings probably reflect the natural variations in s-creatinine levels. This should be taken into consideration when CIN is studied

  16. Assessment of hepatic arterial variation using multidetector helical CT-angiography

    International Nuclear Information System (INIS)

    Lee, Dong Hoon; Lee, Jun Woo; Jun, Woong Bae; Lee, Suk Hong

    2001-01-01

    To evaluate the anatomy of the hepatic artery and normal variants using oblique thick-slab maximal intensity projection (MIP) 3-D CT angiography and multidetector helical CT technology. In 70 patients, axial three-phase CT together with multidetector helical CT and a nonionic contrast agent was used to evaluate liver disease. During the early arterial phase, the parameters were as follow: slice thickness, 2.5 mm; table speed, 15 mm/rotation, pitch, 6; contrast material, 4 ml/sec; total 120 ml. Using the MIP technique and an Advantage window voxtal 3.03 system (GE), the images obtained were reconstructed as 3D angiograms. In each case, the arterial anatomy and its variants were recorded. A typical anatomy was found in 53 cases (75.7%). Common variants were a left hepatic artery arising from the left gastric artery(8 cases, 11.4 %) and a right hepatic artery arising from the superior mesenteric artery(3 cases, 4.3%). Other variant cases were right hepatic artery arising from the gastroduodenal artery(2 cases, 2.9%), a proper hepatic artery arising from the left gastric artery (1 case, 1.4%), a hepatomesenteric trunk (1 case), a hepatogastric/splenomesenteric trunk(1 case), and a celiomesenteric trunk (1 case). 3-D hepatic angiography using multidetector helical CT technology is non-invasive and as accurate as conventional angiography for the evaluation of hepatic arterial anatomy. It is thus considered that 3-D CT angiography is very helpful for the evaluation of hepatic arterial anatomy prior to liver surgery such as transplantation or the treatment of hepatocellular carinoma

  17. Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware

    International Nuclear Information System (INIS)

    Vande Berg, Bruno; Malghem, Jacques; Maldague, Baudouin; Lecouvet, Frederic

    2006-01-01

    Multi-detector CT imaging (MDCT) becomes routine imaging modality in the assessment of the postoperative orthopedic patients with metallic instrumentation that degrades image quality at MR imaging. This article reviews the physical basis and CT appearance of such metal-related artifacts. It also addresses the clinical value of MDCT in postoperative orthopedic patients with emphasis on fracture healing, spinal fusion or arthrodesis, and joint replacement. MDCT imaging shows limitations in the assessment of the bone marrow cavity and of the soft tissues for which MR imaging remains the imaging modality of choice despite metal-related anatomic distortions and signal alteration

  18. Evaluation of tracheal bronchus in Chinese children using multidetector CT

    International Nuclear Information System (INIS)

    Ming, Zhu; Lin, Zhang

    2007-01-01

    Tracheal bronchus is a congenital bronchial anomaly. The diagnosis should be considered early in intubated patients. Multidetector computed tomography (MDCT) is the newest modality for evaluating tracheal bronchus. To evaluate the utility of 16-slice MDCT in children with tracheal bronchus and to characterize the frequency of tracheal bronchus in children with congenital heart disease. From June 2005 to May 2007, 3,187 consecutive children (1,124 with congenital heart disease and 2,063 without congenital heart disease) underwent MDCT examination. Minimum-intensity projection reconstruction was performed to show the tracheobronchial tree in every case. Tracheal bronchus was found in 42 children (3.74%) with congenital heart disease but in only 6 children (0.29%) without congenital heart disease. Among the 48 children with tracheal bronchus, 45 had right-side tracheal bronchus and 3 had bilateral tracheal bronchi with heterotaxy syndrome. The diagnostic sensitivity of MDCT was 100% (48/48). MDCT is a reliable imaging technique for the diagnosis of tracheal bronchus. Our data showed that right-side tracheal bronchus was more common and bilateral tracheal bronchi usually occurred with heterotaxy syndrome. In addition, tracheal bronchus often occurred with congenital heart disease. The angle between the tracheal bronchus and the trachea is important and should be measured. (orig.)

  19. Data explosion: the challenge of multidetector-row CT

    International Nuclear Information System (INIS)

    Rubin, Geoffrey D.

    2000-01-01

    The development of multi detector-row CT has brought many exciting advancements to clinical CT scanning. While multi detector-row CT offers unparalleled speed of acquisition, spatial resolution, and anatomic coverage, a challenge presented by these advantages is the substantial increase on the number of reconstructed cross-sections that are rapidly created and in need of analysis. This manuscript discusses currently available alternative visualization techniques for the assessment of volumetric data acquired with multi detector-row CT. Although the current capabilities of 3-D workstations offer many possibilities for alternative analysis of MCDT data, substantial improvements both in automated processing, processing speed and user interface will be necessary to realize the vision of replacing the primary analysis of transverse reconstruction's with alternative analyses. The direction that some of these future developments might take are discussed

  20. Data explosion: the challenge of multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Rubin, Geoffrey D. E-mail: grubin@standford.edu

    2000-11-01

    The development of multi detector-row CT has brought many exciting advancements to clinical CT scanning. While multi detector-row CT offers unparalleled speed of acquisition, spatial resolution, and anatomic coverage, a challenge presented by these advantages is the substantial increase on the number of reconstructed cross-sections that are rapidly created and in need of analysis. This manuscript discusses currently available alternative visualization techniques for the assessment of volumetric data acquired with multi detector-row CT. Although the current capabilities of 3-D workstations offer many possibilities for alternative analysis of MCDT data, substantial improvements both in automated processing, processing speed and user interface will be necessary to realize the vision of replacing the primary analysis of transverse reconstruction's with alternative analyses. The direction that some of these future developments might take are discussed.

  1. Unenhanced helical CT in the evaluation of the urinary tract in children and young adults following urinary tract reconstruction: comparison with sonography

    Energy Technology Data Exchange (ETDEWEB)

    Myers, M.T.; Elder, J.S.; Sivit, C.J.; Applegate, K.E. [Dept. of Radiology, Rainbow Babies and Children' s Hospital, Cleveland, OH (United States)

    2001-03-01

    Purpose. To compare the accuracy of unenhanced, helical CT with sonography for the detection of complications of urinary tract reconstruction. Materials and methods. Forty-six kidneys in 24 patients were examined with CT and sonography. All scans were assessed for ease of renal visualization, presence of renal, ureteral, and bladder calculi, renal scars, hydronephrosis, and abdominal wall hernia. The results of both imaging modalities were independently reported. Results. CT provided excellent visualization of all 46 kidneys, while sonography provided poor visualization of 8 kidneys (17 %) (P < 0.001). CT detected calculi in 10 kidneys, 1 ureter, and 7 bladders. Sonography detected calculi in only 2 kidneys, and 2 bladders. Overall, CT detected significantly more calculi than US (18 vs 4, P = 0.01). CT detected scarring in 15 kidneys, while sonography detected scarring in 10. Hydronephrosis was detected in 6 kidneys by CT and in 8 kidneys by sonography. Three abdominal wall hernias were seen at CT that were not seen at sonography. Conclusion. CT is superior to sonography for the detection of urinary tract calculi and renal scarring. CT will demonstrate abdominal wall hernias that are unsuspected. (orig.)

  2. Femoral head avascular necrosis: a frequently missed incidental finding on multidetector CT

    International Nuclear Information System (INIS)

    Barille, M.F.; Wu, Jim S.; McMahon, Colm J.

    2014-01-01

    Aim: To determine the incidence of missed femoral head avascular necrosis (AVN) on pelvic computed tomography (CT) performed for clinical indications other than assessment for AVN. Materials and methods: The study was a Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study. The picture archiving and communication system (PACS) database was queried for patients with diagnosis of femoral head AVN on magnetic resonance imaging (MRI), who also underwent pelvic multidetector CT after or <30 days before the MRI examination. The MRI and CT images of 144 hips of 72 patients (39 patients with reported AVN on MRI and 33 age-matched controls; mean age = 60 years, 28 male, 44 female), were reviewed in consensus by two readers in a randomized, blinded manner. Using MRI-proven CT-visible AVN as a reference standard, the incidence of missed AVN on initial CT interpretation was determined. Results: Readers confirmed AVN in 33 patients on the MRI images. Nine hips with AVN underwent joint replacement of the affected joint(s) prior to subsequent CT and were excluded. Forty-three MRI-proven AVN cases in 28 patients (15 bilateral, 13 unilateral) were available for analysis. The study readers diagnosed 35/43 (81%) MRI-proven AVN cases in 22/28 (79%) patients. Four of the 35 (11%) cases of MRI-proven, CT-visible AVN were prospectively reported in 3/22 (14%) patients at initial clinical interpretation, with a miss rate of 89% per hip and 86% per patient. Conclusion: Multidetector CT has high accuracy for detection of AVN; however, this is frequently missed as an incidental finding (89% missed in the present study). Assessment for signs of femoral AVN should be part of routine search pattern in interpretation of pelvic CT

  3. Patent foramen ovale: diagnosis with multidetector CT--comparison with transesophageal echocardiography.

    Science.gov (United States)

    Kim, Young Jin; Hur, Jin; Shim, Chi-Young; Lee, Hye-Jeong; Ha, Jong-Won; Choe, Kyu Ok; Heo, Ji Hoe; Choi, Eui-Young; Choi, Byoung Wook

    2009-01-01

    To evaluate the clinical feasibility and accuracy of 64-section multidetector computed tomography (CT) compared with transesophageal echocardiography (TEE) for diagnosis of a patent foramen ovale (PFO). Institutional review board approval was obtained for this retrospective study. The study included 152 consecutive stroke patients (mean age, 61.7 years; 98 men, 54 women) who underwent both cardiac multidetector CT and TEE. Electrocardiographically gated cardiac CT was performed with a 64-section CT scanner by using a saline-chaser contrast agent injection technique. A contrast agent jet from the contrast agent-filled left atrium (LA) to the saline-filled right atrium (RA) and channel-like appearance of the interatrial septum (IAS) were evaluated on axial and oblique sagittal CT images. Two-dimensional and Doppler TEE were performed to detect PFO. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT were obtained with TEE as the reference standard. A PFO was present in 26 patients at TEE. On CT images, a left-to-right contrast agent jet toward the inferior vena cava was noted in 21 patients (sensitivity, 73.1%; specificity, 98.4%; PPV, 90.5%; NPV, 94.7%). Channel-like appearance of the IAS was detected in 38 patients (sensitivity, 76.9%; specificity, 85.7%; PPV, 52.6%; NPV, 94.7%). Channel-like appearance of the IAS was noted in all patients who had a contrast agent jet. A contrast agent jet from LA to RA toward the inferior vena cava with channel-like appearance of the IAS on CT images confirms the presence of a PFO. (c) RSNA, 2008.

  4. Femoral head avascular necrosis: a frequently missed incidental finding on multidetector CT.

    Science.gov (United States)

    Barille, M F; Wu, Jim S; McMahon, Colm J

    2014-03-01

    To determine the incidence of missed femoral head avascular necrosis (AVN) on pelvic computed tomography (CT) performed for clinical indications other than assessment for AVN. The study was a Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study. The picture archiving and communication system (PACS) database was queried for patients with diagnosis of femoral head AVN on magnetic resonance imaging (MRI), who also underwent pelvic multidetector CT after or AVN on MRI and 33 age-matched controls; mean age = 60 years, 28 male, 44 female), were reviewed in consensus by two readers in a randomized, blinded manner. Using MRI-proven CT-visible AVN as a reference standard, the incidence of missed AVN on initial CT interpretation was determined. Readers confirmed AVN in 33 patients on the MRI images. Nine hips with AVN underwent joint replacement of the affected joint(s) prior to subsequent CT and were excluded. Forty-three MRI-proven AVN cases in 28 patients (15 bilateral, 13 unilateral) were available for analysis. The study readers diagnosed 35/43 (81%) MRI-proven AVN cases in 22/28 (79%) patients. Four of the 35 (11%) cases of MRI-proven, CT-visible AVN were prospectively reported in 3/22 (14%) patients at initial clinical interpretation, with a miss rate of 89% per hip and 86% per patient. Multidetector CT has high accuracy for detection of AVN; however, this is frequently missed as an incidental finding (89% missed in the present study). Assessment for signs of femoral AVN should be part of routine search pattern in interpretation of pelvic CT. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  5. Multi-detector CT urography: effect of oral hydration and contrast medium volume on renal parenchymal enhancement and urinary tract opacification - a quantitative and qualitative analysis

    International Nuclear Information System (INIS)

    Szolar, Dieter H.; Tillich, Manfred; Preidler, Klaus W.

    2010-01-01

    To assess the effect of oral hydration and contrast-medium volume on renal enhancement and urinary tract opacification in multi-detector CT urography. A total of 192 patients were assigned to different protocols with varying doses of contrast agent with and without oral hydration. The attenuation was measured in the renal parenchyma in the unenhanced, nephrographic and excretory phase, and in the urinary tract in excretory phase imaging, respectively. Opacification of the urinary tract was graded on volume rendered images. Oral hydration did not significantly alter renal parenchymal enhancement in both the nephrographic and the excretory phase (p > 0.001), but significantly decreased mean attenuation of the urinary tract in the excretory phase (p ≤ 0.001), and improved continuous opacification of all ureter segments (p < 0.01). Higher volumes of contrast medium improved renal parenchymal enhancement (p ≤ 0.001) and continuous opacification of the urinary tract (p ≤ 0.01). Oral hydration leads to lower attenuation values in the urinary tract but improves the continuous opacification of the tract. Increase in contrast medium volume leads to higher renal parenchymal enhancement as well as to an increased continuous opacification of the urinary tract. Decrease in contrast medium volume cannot be compensated for by oral hydration in terms of parenchymal enhancement. (orig.)

  6. Traumatic thoracic injury: the role of Multidetector-row CT

    International Nuclear Information System (INIS)

    Lim, Se Kyong; Shin, Kyung Sook; Kim, Ha Young; Sung, Jae Kyu; Jung, Hyun Yong; Noh, Seong Moo; Song, Kyu Sang; Cho, June Sik

    2006-01-01

    Hyperplastic polyps are common gastric lesions that are characterized by nonneoplastic epithelial hyperplasia. However, to our knowledge, there are no reports of a hyperplastic polyp arising from an endoscopic mucosectomy site of early gastric cancer. We describe the CT findings with a histopathology correlation in a case of a hyperplastic polyp arising from a mucosectomy site that mimicked polypoid gastric cancer

  7. Traumatic thoracic injury: the role of Multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Se Kyong; Shin, Kyung Sook; Kim, Ha Young; Sung, Jae Kyu; Jung, Hyun Yong; Noh, Seong Moo; Song, Kyu Sang; Cho, June Sik [Chungnam National University School of Medicine, Daejeon (Korea, Republic of)

    2006-05-15

    Hyperplastic polyps are common gastric lesions that are characterized by nonneoplastic epithelial hyperplasia. However, to our knowledge, there are no reports of a hyperplastic polyp arising from an endoscopic mucosectomy site of early gastric cancer. We describe the CT findings with a histopathology correlation in a case of a hyperplastic polyp arising from a mucosectomy site that mimicked polypoid gastric cancer.

  8. In vivo location of the vermiform appendix in multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Su Lim; Ku, Young Mi [Dept. of Radiology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu (Korea, Republic of); Choi, Byung Gil; Byun, Jae Young [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2014-04-15

    To provide a more detailed classification system regarding the position of the vermiform appendix within the right lower quadrant, as seen on multidetector computed tomography (MDCT) and to investigate the relative differences in frequency of appendiceal position according to patient gender and the pathologic state of appendix. Between January 2008 and December 2010, 1157 patients were included in our final analysis: 542 patients with preoperative MDCT and subsequent appendectomy and 615 patients with visible appendix seen on MDCT performed as part of a health checkup. We classified the appendix according to its position relative to the cecum, the terminal ileum, and the external iliac vessels: type 1: antececal; type 2: preileal; type 3: postileal; type 4: subileal; type 5: subcecal; type 6: deep pelvic; type 7: retrocecal; and type 8: paracecal. The relative incidence of various positions of the appendix found in all of our study patients was: type 1: 3.5%; type 2: 1.7%; type 3: 9.0%; type 4: 12.9%; type 5: 42.3%; type 6: 16.2%; type 7: 10.9%; and type 8: 3.0%. According to patient gender, type 1 (male: 3.7% vs. female: 3.3%), type 3 (8.6% vs. 9.8%), type 4 (14.3% vs. 9.8%), type 5 (47.5% vs. 32.7%), type 7 (9.2% vs. 14.4%), and type 8 (3.4% vs. 2.2%) positions showed a statistically significant male predominance. In terms of the inflamed state, type 2 preileal (normal: 0.8% vs. inflamed: 2.8%), type 3 (10.2% vs. 7.6%), type 4 (14.0% vs. 11.6%), and type 5 (14.1% vs. 18.5%) positions showed a statistically significant difference. Contrary to the common assumption that the retrocecal appendix is the most common position, the in vivo appendix is seen more often on MDCT in the subcecal and deep pelvic positions. The relative frequency of various positions of the appendix can also differ according to patient gender and the pathologic state.

  9. Cost-Effectiveness Analysis (CEA) of Intravenous Urography (IVU) and Unenhanced Multidetector Computed Tomography (MDCT) for Initial Investigation of Suspected Acute Ureterolithiasis

    International Nuclear Information System (INIS)

    Eikefjord, E.; Askildsen, J.E.; Roervik, J.

    2008-01-01

    Background: It is important to compare the cost and effectiveness of multidetector computed tomography (MDCT) and intravenous urography (IVU) to determine the most cost-effective alternative for the initial investigation of acute ureterolithiasis. Purpose: To analyze the task-specific variable costs combined with the diagnostic effect of MDCT and IVU for patients with acute flank pain, and to determine which is most cost effective. Material and Methods: 119 patients with acute flank pain suggestive of stone disease (ureterolithiasis) were examined by both MDCT and IVU. Variable costs related to medical equipment, consumption material, equipment control, and personnel were calculated. The diagnostic effect was assessed. Results: The variable costs of MDCT versus IVU were EUR 32 and EUR 117, respectively. This significant difference was mainly due to savings in examination time, higher annual examination frequency, lower material costs, and no use of contrast media. As for diagnostic effect, MDCT proved considerably more accurate in the diagnosis of stone disease than IVU and markedly more accurate concerning differential diagnoses. Conclusion: MDCT had lower differential costs and a higher capacity to determine correctly stone disease and differential diagnoses, as compared to IVU, in patients with acute flank pain. Consequently, MDCT is a dominant alternative to IVU when evaluated exclusively from a cost-effective perspective

  10. Multidetector-row CT angiography of hepatic artery: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Jeong, Yong Yeon; Yoon, Woong; Kim, Jae Kyu; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun

    2003-01-01

    To determine the usefulness of three-dimensional CT angiography using multidetector-row CT (MD-CT) for delineating the arterial anatomy of the liver. Hepatic arterial three-dimensional CT angiography was performed using MDCT (lightspeed Qx/I; GE medical systems, milwaukee, Wis., U.S.A.) in 45 patients with HCC undergoing conventional angiography for transcatheter hepatic arterial chemoembolization. The scanning parameters during the early arterial phase were 2.5 mm slice thickness, 7.5 mm rotation of table speed, and a pitch of 3. Images were obtained by one radiologist using maximum intensity projection from axial CT images obtained during the early arterial phase. Two radiologists blinded to the findings of conventional angiography independently evaluated the hepatic arterial anatomy and the quality of the images obtained. Compared with conventional angiography, reader A correctly evaluated the hepatic arterial anatomy depicted at three-dimensional CT angiography. Reader B's evaluation was correct in 40 of 45 patients. Interobserver agreement was good (kappa value, 0.73), and both readers assessed the quality of three-dimensional CT angiography as excellent. Three-dimensional CT angiography using MDCT was accurate for delineating the arterial anatomy of the liver, and interobserver agreement was good. The modality may provide, prior to conventional angiography, valuable information regrading a patient's hepatic arterial anatomy

  11. Optimal dose and injection duration (injection rate) of contrast material for depiction of hypervascular hepatocellular carcinomas by multidetector CT

    International Nuclear Information System (INIS)

    Yanaga, Yumi; Awai, Kazuo; Nakayama, Yoshiharu; Nakaura, Takeshi; Tamura, Yoshitaka; Yamashita, Yasuyuki; Funama, Yoshinori; Aoyama, Masahito; Asada, Naoki

    2007-01-01

    The aim of this study was to investigate the optimal dose and injection duration of contrast material (CM) for depicting hypervascular hepatocellular carcinomas (HCCs) during the hepatic arterial phase with multidetector row computed tomography (CT). The study population consisted of 71 patients with hypervascular HCCs. After unenhanced scans, the first (early arterial phase, or EAP), second (late arterial phase, or LAP), and third (equilibrium phase) scanning was started at 30, 43, and 180 s after injection of contrast material (CM). During a 33-s period, patients with a body weight ≤50 kg received 100 ml of non-ionic CM with an iodine concentration of 300 mgI/ml; patients whose body weight was >50 kg received 100 ml of CM with an iodine concentration of 370 mgI/ml. First, we measured enhancement in the abdominal aorta and tumor-to-liver contrast (TLC) during the EAP and LAP. Next, to investigate the relation between aortic enhancement and TLC during the LAP, two radiologists visually assessed the conspicuity of hypervascular HCCs during the LAP using a 3-point scale: grade 1, poor; grade 2, fair; grade 3, excellent. Finally, to examine the effect of the CM dose and injection duration on aortic enhancement during the EAP, we simulated aortic enhancement curves using test bolus data obtained for 10 HCC patients and the method of Fleischmann and Hittmair. A relatively strong correlation was observed between aortic enhancement during the EAP and TLC during the LAP (correlation coefficient r=0.75, P 280 HU for aortic enhancement simulations during EAP, the injection duration should be <25 s for patients receiving a CM dose of 1.7 ml/kg with 300 mgI/ml iodine and <30 s for those receiving 2.0 ml/kg. For excellent depiction of hypervascular HCCs during the hepatic arterial phase, the injection duration should be <25 s in patients receiving a CM dose of 1.7 ml/kg with 300 mgI/ml iodine and <30 s for patients receiving 2.0 ml/kg. (author)

  12. Multidetector-Row CT Findings of an Internal Supravesical Hernia: A Case Report

    International Nuclear Information System (INIS)

    Kim, Sang Won; Shin, Hyeong Cheol; Kim, Hyung Hwan; Kim, Young Tong; Kim, Il Young; Kang, Kil Ho

    2010-01-01

    A supravesical hernia occurs in the supravesical fossa and is either classified as an external or internal supravesical hernia. Most patients with internal supravesical hernias present with small bowel obstruction. Internal supravesical hernias are less common than external supravesical hernia. To date, there are few reports describing the radiological findings of supravesical hernias. To our knowledge, this is the first reported multidetector row CT (MDCT) depiction of this type of hernia. We report here on the MDCT findings of a patient with an internal supravesical hernia presenting with small bowel obstruction

  13. Evaluation of aortogenic embolic stroke using multi-detector row CT (MDCT)

    International Nuclear Information System (INIS)

    Mizuno, Masanori; Ooura, Kazumasa; Yamaguchi, Mao; Katsura, Noriyuki; Terayama, Yasuo

    2010-01-01

    Transesophageal cardioechography is one of the useful tools for detecting aortic arteriosclerosis causing aortogenic cerebral embolism. However, it is difficult to perform this method to all of the patients because of the technical difficulties due to patient's condition, especially the severity of atherosclerosis. To avoid the unexpected and adverse events, we are routinely applying multi-detector row CT (MDCT) to those patients. Among 10 cerebral embolic patients with unidentified embolic origin, MDCT revealed arteriosclerotic changes in aorta inducing mobile thrombus in 3 cases. The above data indicates that MDCT is safe and useful tool for diagnosis of aortogenic embolic stroke. (author)

  14. Assessment of chest pain in the emergency room: What is the role of multidetector CT?

    International Nuclear Information System (INIS)

    White, Charles; Read, Katrina; Kuo, Dick

    2006-01-01

    Chest pain is one of the most frequent complaints for patients seen in the emergency department. The current article describes the clinical stratification of patients who present to the emergency department with chest pain and discusses imaging options and analysis for these patients. It reviews conventional imaging approaches to assessing chest pain including chest radiography and stress testing. The main discussion focuses on the potential utility use of cross-sectional imaging, particularly multidetector CT, in the evaluation of chest pain in the emergency department

  15. T-staging of gastric cancer of air-filling multidetector-row CT: Comparison with hydro-multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Kumano, Seishi, E-mail: kumano@radiol.med.kindai.ac.jp [Department of Radiology, Kinki University School of Medicine, Osakasayama, Osaka 589-8511 (Japan); Okada, Masahiro; Shimono, Taro; Kuwabara, Masatomo; Yagyu, Yukinobu; Imaoka, Izumi; Ashikaga, Ryuichiro; Ishii, Kazunari; Murakami, Takamichi [Department of Radiology, Kinki University School of Medicine, Osakasayama, Osaka 589-8511 (Japan)

    2012-11-15

    Purpose: The purpose of this study was to evaluate the accuracy of T-staging of gastric cancer by air-filling multidetector-row CT (air-MDCT) compared with water-filling MDCT (hydro-MDCT). Materials and methods: One hundred fifteen patients with histologically diagnosed gastric cancer were included in this study. Fifty-eight patients underwent air-MDCT, and the remaining 57 had hydro-MDCT using a 64-channel scanner. Based on the volumetric data of contrast-enhanced MDCT obtained about 75 s after intravenously injecting 525 mg iodine per kilogram patients weight (525 mgI/kg) nonionic contrast material at the rate of 2 ml/s, oblique coronal and oblique sagittal multi-planar reformatted images perpendicular to the stomach wall, including the tumor, were reconstructed on a workstation. Mural invasion of gastric cancer into the gastric wall, as visualized by CT, was classified according to the TNM classification, and the results of T-staging by MDCT were compared with those by pathologic analysis after surgery. Results: Correct assessment of T-staging by air-CT was achieved in 48 of 58 patients (83%), and that by hydro-MDCT was 49 of 57 patients (86%). The sensitivity, specificity, and accuracy of the technique in determining the invasion of serosa were 88%, 93%, and 91% for air-CT and 83%, 95%, and 91% for hydro-CT. There were no significant differences between hydro-MDCT and air-MDCT in sensitivity (P = 0.73), specificity (P = 0.71) and accuracy (P = 0.98). Conclusion: Air-MDCT is a very valuable tool in T-staging of gastric cancer as well as hydro-MDCT.

  16. Multidetector CT and MRI findings in periportal space pathologies

    Energy Technology Data Exchange (ETDEWEB)

    Karcaaltincaba, Musturay [Department of Radiology, Hacettepe University School of Medicine, Ankara 06100 (Turkey)]. E-mail: musturayk@yahoo.com; Haliloglu, Mithat [Department of Radiology, Hacettepe University School of Medicine, Ankara 06100 (Turkey); Akpinar, Erhan [Department of Radiology, Hacettepe University School of Medicine, Ankara 06100 (Turkey); Akata, Deniz [Department of Radiology, Hacettepe University School of Medicine, Ankara 06100 (Turkey); Ozmen, Mustafa [Department of Radiology, Hacettepe University School of Medicine, Ankara 06100 (Turkey); Ariyurek, Macit [Department of Radiology, Hacettepe University School of Medicine, Ankara 06100 (Turkey); Akhan, Okan [Department of Radiology, Hacettepe University School of Medicine, Ankara 06100 (Turkey)

    2007-01-15

    Periportal region is an anatomic space around portal vein comprising hepatic artery, bile duct, nerves, lymphatics and a potential space. Periportal pathologies may involve any of these structures diffusely or focally with characteristic radiologic findings. Radiologic findings can be helpful in differential diagnosis of pathologies of periportal structures including periportal cavernomatous transformation, hepatic artery aneurysm, biliary diseases, neurofibromatosis, lymphoma, langerhans' cell histiocytosis, periportal fatty infiltration and other causes of periportal halo in adult and pediatric patients. Lobar/segmental intrahepatic involvement can be seen in neurofibromatosis, cavernomatous transformation, fatty infiltration and periportal edema. In this review, we discuss CT and MRI findings of periportal pathologies which can be in the form of diffuse or segmental/lobar involvement.

  17. Virtual anthropology and forensic identification using multidetector CT.

    Science.gov (United States)

    Dedouit, F; Savall, F; Mokrane, F-Z; Rousseau, H; Crubézy, E; Rougé, D; Telmon, N

    2014-04-01

    Virtual anthropology is made possible by modern cross-sectional imaging. Multislice CT (MSCT) can be used for comparative bone and dental identification, reconstructive identification and lesion identification. Comparative identification, the comparison of ante- and post-mortem imaging data, can be performed on both teeth and bones. Reconstructive identification, a considerable challenge for the radiologist, identifies the deceased by determining sex, geographical origin, stature and age at death. Lesion identification combines virtual autopsy and virtual anthropology. MSCT can be useful in palaeopathology, seeking arthropathy, infection, oral pathology, trauma, tumours, haematological disorders, stress indicators or occupational stress in bones and teeth. We examine some of the possibilities offered by this new radiological subspeciality that adds a new dimension to the work of the forensic radiologist. A multidisciplinary approach is crucial and involves communication and data exchange between radiologists, forensic pathologists, anthropologists and radiographers.

  18. Importance of multidetector CT imaging in multiple trauma; Stellenwert der Multidetektor-CT bei Polytrauma

    Energy Technology Data Exchange (ETDEWEB)

    Linsenmaier, U. [HELIOS Kliniken Muenchen West, HELIOS Klinik Muenchen Perlach, Institut fuer Diagnostische und Interventionelle Radiologie, Muenchen (Germany); Geyer, L.L.; Reiser, M.; Wirth, S. [Klinikum der Ludwig-Maximilians-Universitaet, Institut fuer Klinische Radiologie, Muenchen (Germany); Koerner, M. [Radiologie Muehleninsel, Landshut (Germany)

    2014-09-15

    Diagnostic imaging of complex multiple trauma remains a challenge for any department providing modern emergency radiology (ER) service. An early and comprehensive approach for ER imaging is crucial for a priority-oriented and timely therapy concept with the aim of identifying potentially life-threatening injuries early and initiating appropriate treatment. The basic diagnostic approach still consists of focused ultrasound using focused assessment with sonography for trauma (FAST) and conventional radiography (CR), usually limited to a single supine chest x-ray for triaging patients undergoing immediate operations. Multidetector computed tomography (MDCT) has become established as early whole body CT (WBCT) as the undisputable diagnostic method. The detection rate of injuries by WBCT is outstanding and it improves the probability of survival by 20-25 % compared with all other previous methods. At the same time, the spatial and temporal resolution of MDCT was improved resulting in considerably shortened examination times but WBCT is still associated with a significant radiation exposure, even in the acute single use setting. Using modern scanner and dose reduction technology, including iterative reconstruction, a dose reduction of up to 40 % could be achieved. The substantial number of images in WBCT is another challenge; images must be processed priority-oriented, read and transferred to the picture archiving and communications system (PACS). For rapid diagnosis, volume image reading (VIR) offers additional options to keep the diagnostic process on time. Modern WBCT after multiple trauma is performed early, comprehensively and personalized so that WBCT improves the probability of survival by 20-25 %. (orig.) [German] Die Diagnostik komplexer Mehrfachverletzungen ist eine Herausforderung fuer die moderne radiologische Notfalldiagnostik. Eine umfassend angelegte, fruehe und praezise radiologische Diagnostik ist entscheidend fuer eine prioritaetenorientierte und

  19. Accuracy of multidetector CT in detecting anastomotic leaks following stapled left-sided colonic anastomosis

    International Nuclear Information System (INIS)

    Kaur, P.; Karandikar, S.S.; Roy-Choudhury, S.

    2014-01-01

    Aims: To assess accuracy of multidetector computed tomography (MDCT) and individual radiological signs in the diagnosis of anastomotic leaks. Materials and methods: Patients undergoing anterior resection with a stapled anastomosis over a 2 year period were identified. Electronic and clinical records of these patients were reviewed. Unenhanced and/or enhanced MDCT was performed with intravenous and/or per-rectal contrast medium and read by a radiologist blinded to the patients' clinical details to determine the sensitivity and specificity of specific findings at MDCT for identifying leaks. Results: Seventeen percent (30/170) of the anterior resections were suspected to have an anastomotic leak. Ninety-three percent (28/30) of patients underwent MDCT. Seven point six percent (11+2/170) had a confirmed leak. Two patients underwent surgery without MDCT. A leak was confirmed by MDCT in 91% (10/11) of patients. The sensitivity, specificity, and positive and negative predictive values of MDCT in diagnosing a leak was 0.91, 1, 1, and 0.95, respectively. The sensitivity of peri-anastomotic air, peri-anastomotic collection, extravasation of rectal contrast medium, and staple line integrity was 0.81, 0.63, 0.54, and 0.72, respectively. Use of rectal contrast medium (8/11 cases) increased the subjective ease of diagnosis and was the only sign in one patient. Conclusions: Presence of peri-anastomotic air is a reliable marker of anastomotic leaks at MDCT. Leakage of rectal contrast medium is highly accurate and increases confidence of diagnosis. The appearance of the staple line itself is not accurate in assessing anastomotic integrity

  20. Quantitative measurement of radiofrequency volumetric tissue reduction by multidetector CT in patients with inferior turbinate hypertrophy.

    Science.gov (United States)

    Bahadir, Osman; Kosucu, Polat

    2012-12-01

    To objectively assess the efficacy of radiofrequency thermal ablation of inferior turbinate hypertrophy. Thirty-five patients with nasal obstruction secondary to inferior turbinate hypertrophy were prospectively enrolled. Radiofrequency energy was delivered to four sites in each inferior turbinate. Patients were evaluated before and 8 weeks after intervention. Subjective evaluation of nasal obstruction was performed using a visual analogue scale (VAS), and objective evaluation of the turbinate volume reduction was calculated using multidetector CT. Volumetric measurements of the preoperative inferior turbinate were compared with postoperative values on both sides. The great majority of patients (91.4%) exhibited subjective postoperative improvement. Mean obstruction (VAS) improved significantly from 7.45±1.48 to 3.54±1.96. Significant turbinate volume reduction was achieved by the surgery on both right and left sides [(preoperative vs. postoperative, right: 6.55±1.62cm(3) vs. 5.10±1.47cm(3), (PRadiofrequency is a safe and effective surgical procedure in reducing turbinate volume in patients with inferior turbinate hypertrophy. Multidetector CT is an objective method of assessment in detecting radiofrequency turbinate volume reduction. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  1. Quantitative assessment of bone defect healing by multidetector CT in a pig model

    International Nuclear Information System (INIS)

    Riegger, Carolin; Kroepil, Patric; Lanzman, Rotem S.; Miese, Falk R.; Antoch, Gerald; Scherer, Axel; Jungbluth, Pascal; Hakimi, Mohssen; Wild, Michael; Hakimi, Ahmad R.

    2012-01-01

    To evaluate multidetector CT volumetry in the assessment of bone defect healing in comparison to histopathological findings in an animal model. In 16 mini-pigs, a circumscribed tibial bone defect was created. Multidetector CT (MDCT) of the tibia was performed on a 64-row scanner 42 days after the operation. The extent of bone healing was estimated quantitatively by MDCT volumetry using a commercially available software programme (syngo Volume, Siemens, Germany).The volume of the entire defect (including all pixels from -100 to 3,000 HU), the nonconsolidated areas (-100 to 500 HU), and areas of osseous consolidation (500 to 3,000 HU) were assessed and the extent of consolidation was calculated. Histomorphometry served as the reference standard. The extent of osseous consolidation in MDCT volumetry ranged from 19 to 92% (mean 65.4 ± 18.5%). There was a significant correlation between histologically visible newly formed bone and the extent of osseous consolidation on MDCT volumetry (r = 0.82, P < 0.0001). A significant negative correlation was detected between osseous consolidation on MDCT and histological areas of persisting defect (r = -0.9, P < 0.0001). MDCT volumetry is a promising tool for noninvasive monitoring of bone healing, showing excellent correlation with histomorphometry. (orig.)

  2. Quantitative assessment of bone defect healing by multidetector CT in a pig model

    Energy Technology Data Exchange (ETDEWEB)

    Riegger, Carolin; Kroepil, Patric; Lanzman, Rotem S.; Miese, Falk R.; Antoch, Gerald; Scherer, Axel [University Duesseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Duesseldorf (Germany); Jungbluth, Pascal; Hakimi, Mohssen; Wild, Michael [University Duesseldorf, Medical Faculty, Department of Traumatology and Hand Surgery, Duesseldorf (Germany); Hakimi, Ahmad R. [Universtity Duesseldorf, Medical Faculty, Department of Oral Surgery, Duesseldorf (Germany)

    2012-05-15

    To evaluate multidetector CT volumetry in the assessment of bone defect healing in comparison to histopathological findings in an animal model. In 16 mini-pigs, a circumscribed tibial bone defect was created. Multidetector CT (MDCT) of the tibia was performed on a 64-row scanner 42 days after the operation. The extent of bone healing was estimated quantitatively by MDCT volumetry using a commercially available software programme (syngo Volume, Siemens, Germany).The volume of the entire defect (including all pixels from -100 to 3,000 HU), the nonconsolidated areas (-100 to 500 HU), and areas of osseous consolidation (500 to 3,000 HU) were assessed and the extent of consolidation was calculated. Histomorphometry served as the reference standard. The extent of osseous consolidation in MDCT volumetry ranged from 19 to 92% (mean 65.4 {+-} 18.5%). There was a significant correlation between histologically visible newly formed bone and the extent of osseous consolidation on MDCT volumetry (r = 0.82, P < 0.0001). A significant negative correlation was detected between osseous consolidation on MDCT and histological areas of persisting defect (r = -0.9, P < 0.0001). MDCT volumetry is a promising tool for noninvasive monitoring of bone healing, showing excellent correlation with histomorphometry. (orig.)

  3. Multidetector-row helical CT: analysis of time management and workflow

    Energy Technology Data Exchange (ETDEWEB)

    Roos, Justus E.; Desbiolles, Lotus M.; Willmann, Juergen K.; Weishaupt, Dominik; Marincek, Borut; Hilfiker, Paul R. [Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland)

    2002-03-01

    The purpose of this study was to evaluate time management and workflow for multidetector-row helical CT (MDCT). Time for patient and data handling of at total of 580 patients were evaluated at two different time periods (December 1999, August 2000), each for the following baseline measurements: (a) change of clothes/instruction; (b) patient placement on the CT table/i.v. catheter; (c) CT planning and programming; (d) CT data acquisition; (e) CT data reconstruction; (f) CT data storage/printing. All imaging was performed on a Somatom Volume Zoom (Siemens, Erlangen, Germany). Time measurements summarized for different CT protocols revealed the following: (a) 5:01 min ({+-}2.06 min); (b) 4:36 min ({+-}2.43 min); (c) 4:11 min ({+-}2.55 min); (d) 0:43 min ({+-}0.15 min); (e) 6:59 min ({+-}2.39 min); (f) 09:51 min ({+-}3.51 min). Planning and programming was most time-consuming for CT angiography, whereas chest and abdominal CT needed only 3:26 and 3:30 min, respectively. Reconstruction time was highest for HRCT (9:22 min) and CTA (9:03 min). Data storage/printing was most time-consuming for HRCT (13:02 min), followed by combined neck-chest-abdomen examinations (12:19 min). Comparing the two time periods, during which a software update was performed, a mean time reduction of 4:31 min per patient (15%, p<0.001) was achieved. Whereas CT data acquisition time is no longer a problem with MDCT, patient management, data reconstruction, and data storage are the most time-consuming parts. Well-trained technicians, state-of-the-art workstations, and fast networking are the most important factors to improve workflow. (orig.)

  4. Congenital heart diseases: post-operative appearance on multi-detector CT - a pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Tomasian, Anderanik; Malik, Sachin; Shamsa, Kamran; Krishnam, Mayil S. [UCLA Medical Center, Department of Radiological Science, Los Angeles, CA (United States)

    2009-12-15

    Echocardiography is considered as an initial imaging modality of choice in patients with congenital heart disease (CHD), and magnetic resonance (MR) imaging is preferred for detailed functional information. Multi-detector computed tomography (CT) plays an important role in clinical practice in assessing post-operative morphological and functional information of patients with complex CHD when echocardiography and MR imaging are not contributory. Radiologists should understand and become familiar with the complex morphology and physiology of CHD, as well as with various palliative and corrective surgical procedures performed in these patients, to obtain CT angiograms with diagnostic quality and promptly recognise imaging features of normal post-operative anatomy and complications of these complex surgeries. (orig.)

  5. Current development of cardiac imaging with multidetector-row CT

    International Nuclear Information System (INIS)

    Becker, Christoph R.; Ohnesorge, Bernd M.; Schoepf, U. Joseph; Reiser, Maximilian F.

    2000-01-01

    Multidector-row CT (MDCT) with retrospective ECG gating allows scanning the entire heart with 1.25 mm slice thickness and 250 ms effective exposure time within 35 s investigation time. The resulting images allow for an accurate high-resolution assessment of morphological detail of both the coronary arteries and the cardiac chambers. Performing a contrast-enhanced MDCT angiography (MD-CTA) in addition to a non-enhanced scan for the detection and quantification of coronary calcifications may be indicated in patients with atypical chest pain and in young patients with high cardiovascular risk. This group of patients may show non-calcified plaques as the first sign of their coronary artery disease. As the proximal part of the coronary arteries is well displayed by MD-CTA it also helps to delineate the course in anomalous coronary vessels. Additional information is drawn from the preoperative use of MD-CTA do determine the distance of the left internal mammarian artery to the left anterior descending coronary artery prior to minimal invasive bypass grafting. Additional indications for MD-CTA are the non-invasive follow up after venous bypass grafting, PTCA, and coronary stent interventions. MD-CTA allows following the course of the coronary vessels to the level of third generation coronary segmental arteries. A definite diagnosis to rule out coronary artery disease can be reliably made in vessels with a diameter of 1.5 mm or greater. With MDCT a number of different atherosclerotic changes can be observed in diseased coronary arteries. Non-stenotic lesions may show tiny calcifications surrounded by large areas of irregularly distributed soft tissue. Calcifications in this type of atherosclerotic coronary artery wall changes appear as 'the tip of iceberg'. Heavy calcifications usually tend to be non-stenotic because of vessel remodelling resulting in a widening of the coronary vessel lumen. Therefore, heavy calcifications appear to act like an 'internal stent' for a

  6. Multidetector Row CT Detection of a Patent Foramen Ovale Causing Neurologic Deficits in an Adolescent: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Bin [Dept. of Radiology, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); Kim, Dong Hun; Oh, Jae Hee [Dept. of Radiology, Chosun University College of Medicine, Gwangju (Korea, Republic of); Seo, Hye Sun [Dept. of Internal Medicine, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); Suk, Eun Ha [Dept. of Anesthesiology and Pain Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2012-02-15

    A patent foramen ovale (PFO) is a persisting fetal circulation structural abnormality that can cause neurologic deficits such as migraine and cryptogenic stroke. Here we report a case of PFO diagnosed by cardiac multidetector row CT in an adolescent male with chronic migraine and stroke.

  7. Multidetector Row CT Detection of a Patent Foramen Ovale Causing Neurologic Deficits in an Adolescent: A Case Report

    International Nuclear Information System (INIS)

    Lee, Jung Bin; Kim, Dong Hun; Oh, Jae Hee; Seo, Hye Sun; Suk, Eun Ha

    2012-01-01

    A patent foramen ovale (PFO) is a persisting fetal circulation structural abnormality that can cause neurologic deficits such as migraine and cryptogenic stroke. Here we report a case of PFO diagnosed by cardiac multidetector row CT in an adolescent male with chronic migraine and stroke.

  8. Peliosis Hepatis with Hemorrhagic Necrosis and Rupture: a Case Report with Emphasis on the Multi-Detector CT Findings

    OpenAIRE

    Kim, Eun-A; Yoon, Kwon-Ha; Jeon, Se-Jung; Cai, Quan-Yu; Lee, Young-Whan; Yoon, Seong Eon; Yoon, Ki-Jung; Juhng, Seon-Kwan

    2007-01-01

    We report here on an uncommon case of peliosis hepatis with hemorrhagic necrosis that was complicated by massive intrahepatic bleeding and rupture, and treated by emergent right lobectomy. We demonstrate the imaging findings, with emphasis on the triphasic, contrast-enhanced multidetector CT findings, as well as reporting the clinical outcome in a case of peliosis hepatis with fatal hemorrhage.

  9. Dose reduction in multidetector CT of the urinary tract. Studies in a phantom model

    International Nuclear Information System (INIS)

    Coppenrath, E.; Meindl, T.; Herzog, P.; Khalil, R.; Mueller-Lisse, U.; Krenn, L.; Reiser, M.; Mueller-Lisse, U.G.

    2006-01-01

    A novel ureter phantom was developed for investigations of image quality and dose in CT urography. The ureter phantom consisted of a water box (14 cm x 32 cm x 42 cm) with five parallel plastic tubes (diameter 2.7 mm) filled with different concentrations of contrast media (1.88-30 mg iodine/ml). CT density of the tubes and noise of the surrounding water were determined using two multidetector scanners (Philips MX8000 with four rows, Siemens Sensation 16 with 16 rows) with varying tube current-time product (15-100 mAs per slice), voltage (90 kV, 100 kV, 120 kV), pitch (0.875-1.75), and slice thickness (1 mm, 2 mm, 3.2 mm). Contrast-to-noise ratio as a parameter of image quality was correlated with dose (CTDI) and was compared with image evaluation by two radiologists. The CT densities of different concentrations of contrast media and contrast-to-noise ratio were significantly higher when low voltages (90 kV versus 120 kV, 100 kV versus 120 kV) were applied. Smaller slice thickness (1 mm versus 2 mm) did not change CT density but decreased contrast-to-noise ratio due to increased noise. Contrast phantom studies showed favourable effects of low tube voltage on image quality in the low dose range. This may facilitate substantial dose reduction in CT urography. (orig.)

  10. Radiological evaluation with Doppler sonography and multidetector CT angiography in congenital hepatic arteriovenous malformation in a newborn

    Energy Technology Data Exchange (ETDEWEB)

    Adaletli, Ibrahim; Kurugoglu, Sebuh; Kilic, Fahrettin [Istanbul University, Department of Radiology, Cerrahpasa Medical Faculty (Turkey); Senyuz, Osman F. [Istanbul University, Department of Paediatric Surgery, Cerrahpasa Medical Faculty (Turkey); Dervisoglu, Sergulen [Istanbul University, Department of Pathology, Cerrahpasa Medical Faculty (Turkey)

    2006-11-15

    Although hepatic arteriovenous malformations are rarely reported, they frequently have life-threatening complications such as cardiac failure and are associated with a high mortality rate. Consequently, accurate prenatal and early postnatal diagnosis is important and therapeutic procedures depend on the imaging features. We report the early postnatal sonographic, Doppler sonographic, multidetector CT and CT angiography findings of a congenital hepatic arteriovenous malformation in a newborn. (orig.)

  11. Radiological evaluation with Doppler sonography and multidetector CT angiography in congenital hepatic arteriovenous malformation in a newborn

    International Nuclear Information System (INIS)

    Adaletli, Ibrahim; Kurugoglu, Sebuh; Kilic, Fahrettin; Senyuz, Osman F.; Dervisoglu, Sergulen

    2006-01-01

    Although hepatic arteriovenous malformations are rarely reported, they frequently have life-threatening complications such as cardiac failure and are associated with a high mortality rate. Consequently, accurate prenatal and early postnatal diagnosis is important and therapeutic procedures depend on the imaging features. We report the early postnatal sonographic, Doppler sonographic, multidetector CT and CT angiography findings of a congenital hepatic arteriovenous malformation in a newborn. (orig.)

  12. Preoperative staging of esophageal carcinoma with multidetector CT and virtual endoscopy

    International Nuclear Information System (INIS)

    Onbas, Omer; Eroglu, Atilla; Kantarci, Mecit; Polat, Pinar; Alper, Fatih; Karaoglanoglu, Nurettin; Okur, Adnan

    2006-01-01

    Purpose: The aim of this study was to assess the accuracy of multidetector computed tomography (MDCT), including virtual endoscopy (VE) for detection, precise localization, preoperative evaluation and staging of esophageal cancer (EC) by comparison with surgical and histopathological findings. Materials and methods: Between September 2003 and April 2005, 44 patients with histologically proven EC underwent MDCT and VE. Among 44 patients, the findings were confirmed in 24 at surgery. The accuracy of three-dimensional MDCT for detection, localization, and staging of EC was determined, and compared with surgical finding and histopathology. Results: The overall accuracy of three-dimensional multidetector row CT for detection of EC was 100% (24/24). MDCT staging was correct in 20 patients (83.3%). The T parameter was correctly assessed in 22 (91.7%) cases (understaged in 1 and overstaged in 1). The N parameter was correctly evaluated in 20 (83.4%) patients (understaged in 2 and overstaged in 2). The overall accuracy of VE for the morphologic classification of EC was 81.5%. Conclusions: Three-dimensional MDCT, along with VE is a promising method for preoperative evaluation and staging of EC. Although accuracy in N staging remains low in comparison to PET, it provides a larger amount of diagnostic and staging information

  13. Diagnostic assessment of painless microhematuria: prospective study comparing image quality, assessibility and diagnostic certainty of multidetector-row CT and intravenous pyelography within a single examination

    International Nuclear Information System (INIS)

    Boehm, T.; John, H.; Ruedi, C.; Marincek, B.; Wildermuth, S.; Michael, M.

    2005-01-01

    Purpose: The purpose of this study is to prospectively compare intravenous pyelography (IVP) and combined unenhanced and excretory phase multidetector-row CT (MDCT) with respect to image quality, diagnostic certainty and diagnostic concordance with the final clinical diagnosis in patients with painless microhematuria. Materials and Methods: Unenhanced MDCT, IVP and excretory phase MDCT were performed in 59 consecutive patients (21 women, 38 men, mean age 56±19 years, range 23-83 years) with painless microhematuria of unknown origin during a single examination with a single contrast media application (100 ml, non-ionic iodinate contrast media). Images were assessed by two experienced urogenital radiologists in consensus for image quality, diagnostic certainty of stone detection, obstruction, parenchymal lesions and morphological distinctive features. Imaging diagnoses of MDCT and IVP were compared with the final clinical diagnoses. In case of failure to detect an relevant pathology, the final clinical diagnosis was established after a mean follow-up period of 18±6 months (10 months to 2 years). Costs and radiation exposure of IVP and MDCT were compared. Results: MDCT scan performed better than IVP in terms of image quality for all regarded variables. Image quality of MDCT was rated in all parameters as very good or good; the image quality of IVP differed in a wide range. MDCT and IVP reached a sensitivity of 100% and 50% for stone detection (n=14, p=0.008), respectively. Two bladder stones were not detected by IVU but correctly seen with MDCT. MDCT and IVP were unsatisfactory for detecting transitional cell carcinomas (n=4, 2 of 4 detected with MDCT, 0 of 4 detected with IVU). One false positive transitional cell carcinoma was detected with IVP, none with MDCT. Additional relevant pathological changes (one teratoma, one abdominal aortic aneurysma and one abscess) were detected using MDCT but missed with IVP. In 38 of 59 patients (64%) imaging and clinical follow

  14. Multidetector CT for congenital heart patients: what a paediatric radiologist should know

    Energy Technology Data Exchange (ETDEWEB)

    Paul, Jean-Francois; Rohnean, Adela; Sigal-Cinqualbre, Anne [Radiology Unit, Marie Lannelongue Hospital, Plessis-Robinson (France)

    2010-06-15

    Multidetector CT (MDCT) is increasingly used for imaging congenital heart disease (CHD) patients in addition to echocardiography, due to its ability to provide high quality three-dimensional images, giving a comprehensive evaluation of complex heart malformations. Using 4-slice or 16-slice CT, diagnostic information in CHD patients is limited to extra-cardiac anatomy, mainly the pulmonary arteries, aorta and venous connections. Due to high heart rates in babies however, coronary evaluation and intra-cardiac analysis were not reliable with the first generations of MDCT. Larger detector size with 64-slice CT and faster acquisition time, up to 75 ms for one slice, has progressively improved coronary and intra-cardiac visualization. Because radiation dose is the main concern, especially in children, every attempt to minimize dose whilst preserving image quality is important: the ALARA concept should always be applied in this population. The 80 kVp setting is now well accepted as a standard for more and more radiological teams involved in CT of children. Different acquisition strategies are now possible for childhood coronary imaging, using retrospective or even prospective gating. Using the latest technology, sub-mSv acquisitions are now attainable for scanning a whole thorax, providing a complete analysis of any 3-D cardiac malformation, including coronary artery course visualisation. This review will describe how technological developments have improved image quality with continuous reduction of radiation dose. (orig.)

  15. Measurement of Trabecular Bone Parameters in Porcine Vertebral Bodies Using Multidetector CT: Evaluation of Reproducibility of 3-Dimensional CT Histomorphometry

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sung Hwan; Goo, Jin Mo [Dept. of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Moon Kyung Chul [Dept. of Pathology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); An, Sang Bu [Dept. of radiology, National Cancer Center, Goyang (Korea, Republic of); Kim, Kwang Gi [Dept. of Biomedical Engineering, Division of Basic and Applied Sciences, National Cancer Center, Goyang (Korea, Republic of)

    2011-05-15

    To evaluate the reproducibility of 3-dimensional histomorphometry for the microarchitecture analysis of trabecular bone parameters using multidetector computed tomography (MDCT). Thirty-six specimens from porcine vertebral bodies were imaged five times with a 64- detector row MDCT system using the same scan protocols. Locations of the specimens were nearly identical through the scans. Three-dimensional structural parameters of trabecular bone were derived from the five data sets using image analyzing software. The features measured by the analysis programs were trabecular bone volume, trabecular bone volume/tissue volume, trabecular thickness, trabecular separation, trabecular number, trabecular bone pattern factor, structural model index. The structural trabecular parameters showed excellent reproducibility through repeated scanning. Intraclass correlation coefficients of all seven structural parameters were in the range of 0.998 to 1.000. Coefficients of variation of the six structural parameters, excluding structural model index, were not over 1.6%. The measurement of the trabecular structural parameters using multidetector CT and three-dimensional histomophometry analysis program was validated and showed excellent reproducibility. This method could be used as a noninvasive and easily available test in a clinical setting.

  16. 64 multidetector CT findings of influenza A (H1N1) virus in patients with hematologic malignancies

    International Nuclear Information System (INIS)

    El-Badrawy, Adel; Zeidan, Amany; Ebrahim, Mohamed A.

    2012-01-01

    Background. The pandemic of swine-origin H1N1 influenza that began in early 2009 has provided evidence that radiology can assist in the early diagnosis of severe cases. Immunocompromised patients are at increased risk for morbidity and mortality. MDCT is superior to radiography in showing the distribution of the disease. Purpose. To review the 64 multidetector CT thoracic findings of novel swine-origin influenza A (H1N1) virus in patients with hematologic malignancies. Material and Methods. This study included 12 patients (3 women, 9 men; mean age, 32.2 years). All patients proved to be infected with influenza A (H1N1) virus. The hematologic malignancies were acute myeloid leukemia (n = 8), chronic lymphocytic leukemia (n = 2), multiple myeloma (n = 1), and myelodysplastic syndrome (n = 1). All the patients underwent CT scanning using a 64 multidetector CT scanner. Chest CT scans were reviewed for ground-glass opacities (GGOs), consolidation, airway thickening/dilatation, nodules, mediastinal lymphadenopathy, and pleural effusion. Results. More than one CT finding was detected in every patient. Pulmonary affection was bilateral, more on the left side. The affections were mainly peribronchial. Airway wall thickening and dilatation were detected in all 12 patients, GGO in 9/12 patients, nodules in 6/12 patients, consolidation in 6/12 patients, hilar lymphadenopathy in 3/12 patients, and pleural effusion in 2/12 patients. Conclusion. Acute myeloid leukemia is the most common hematologic malignancy affected by influenza A (H1N1) virus. The left lung is affected more than the right one. The most common multidetector CT findings are unilateral or bilateral airway thickening and dilatation. Multidetector CT can be used for early and accurate assessment of pulmonary affection with influenza A H1N1 virus infection

  17. 64 multidetector CT findings of influenza A (H1N1) virus in patients with hematologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    El-Badrawy, Adel [Dept. of Radiology, Mansoura Faculty of Medicine, Mansoura (Egypt)], E-mail: adelelbadrawy@hotmail.com; Zeidan, Amany [Dept. of Thoracic Medicine, Mansoura Faculty of Medicine, Mansoura (Egypt); Ebrahim, Mohamed A. [Dept. of Medical Oncology, Mansoura Faculty of Medicine, Mansoura (Egypt)

    2012-07-15

    Background. The pandemic of swine-origin H1N1 influenza that began in early 2009 has provided evidence that radiology can assist in the early diagnosis of severe cases. Immunocompromised patients are at increased risk for morbidity and mortality. MDCT is superior to radiography in showing the distribution of the disease. Purpose. To review the 64 multidetector CT thoracic findings of novel swine-origin influenza A (H1N1) virus in patients with hematologic malignancies. Material and Methods. This study included 12 patients (3 women, 9 men; mean age, 32.2 years). All patients proved to be infected with influenza A (H1N1) virus. The hematologic malignancies were acute myeloid leukemia (n = 8), chronic lymphocytic leukemia (n = 2), multiple myeloma (n = 1), and myelodysplastic syndrome (n = 1). All the patients underwent CT scanning using a 64 multidetector CT scanner. Chest CT scans were reviewed for ground-glass opacities (GGOs), consolidation, airway thickening/dilatation, nodules, mediastinal lymphadenopathy, and pleural effusion. Results. More than one CT finding was detected in every patient. Pulmonary affection was bilateral, more on the left side. The affections were mainly peribronchial. Airway wall thickening and dilatation were detected in all 12 patients, GGO in 9/12 patients, nodules in 6/12 patients, consolidation in 6/12 patients, hilar lymphadenopathy in 3/12 patients, and pleural effusion in 2/12 patients. Conclusion. Acute myeloid leukemia is the most common hematologic malignancy affected by influenza A (H1N1) virus. The left lung is affected more than the right one. The most common multidetector CT findings are unilateral or bilateral airway thickening and dilatation. Multidetector CT can be used for early and accurate assessment of pulmonary affection with influenza A H1N1 virus infection.

  18. Multidetector CT angiography influences the choice of treatment for blunt carotid artery injury.

    Science.gov (United States)

    Beliaev, Andrei M; Civil, Ian

    2014-08-06

    A 43-year-old woman presented with a 2 h history of left neck pain after striking her neck against a marble bench while playing with her son. The patient was screened for blunt cerebrovascular injury (BCVI) and a left carotid bruit was identified. Subsequently, she underwent multidetector CT angiography (MCTA) of the aortic arch and neck vessels, which demonstrated a flow-limiting dissection of the left common carotid artery (CCA). The patient was started on heparin infusion and underwent an emergency operation. At surgery, a circumferential intimal dissection was excised and the arteriotomy defect closed with an autologous venous patch. This case emphasises the importance of adequately examining patients with direct injury to the neck, screening relevant patients for BCVI and investigating them with MCTA that influences the choice of a treatment option. 2014 BMJ Publishing Group Ltd.

  19. Usefulness of multiplanar reformatted images of multi-detector row helical CT in assessment of biliary stent patency

    International Nuclear Information System (INIS)

    Kim, Soo Jin; Kim, Suk; Kim, Chang Won; Lee, Jun Woo; Lee, Tae Hong; Choo, Ki Seok; Koo, Young Baek; Moon, Tae Yong; Lee, Suk Hong

    2004-01-01

    To evaluate the usefulness of multi-detector row helical CT (MDCT), multiplanar reformatted images for the noninvasive assessment of biliary stent patency, and for the planning for management in patients with a sele-expandable metallic stent due to malignant biliary obstruction. Among 90 consecutive patients, from August 1999 to July 2003, 26 cases in 23 patients with malignant biliary obstruction who underwent self-expandable metaIlic stent insertion in the biliary system and percutaneous transhepatic biliary drainage within 7 days after CT were enrolled in this study. On CT images, the complete and functional obstruction of the stent and the precise level of obstruction were evaluated. The presence of an enhancing intraluminal mass or wall thickening around stent was determined, and the causes of obstruction were evaluated. These findings were then compared with percutaneous transhepatic cholangiography. Multi-detector row helical CT correctly demonstrated the patency of a stent in 24 cases (92.3%). It was adequate in helping to depict the precise level of stent occlusion in 23 cases (88.5%). Multi-detector row helical CT also revealed the extent of tumor that represented as an enhancing intraluminal mass or wall thickening around the stent in 23 cases, and this was represented as complete obstruction on percutaneous transhepatic cholangiography. In the case of functional obstruction, MDCT predicted the possible cause of the obstruction. Multiplanar reformatted images of multi-detector row helical CT is a useful imaging modality for the noninvasive assessment of stent patency and the precise level of obstruction when stent obstruction is suspected in the patients with self-expandable metallic stent due to malignant biliary obstruction. It can also predict the possible cause of the obstruction and allows adequate planning for the medical management of such cases

  20. Usefulness of multiplanar reformatted images of multi-detector row helical CT in assessment of biliary stent patency

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Jin; Kim, Suk; Kim, Chang Won; Lee, Jun Woo; Lee, Tae Hong; Choo, Ki Seok; Koo, Young Baek; Moon, Tae Yong; Lee, Suk Hong [Pusan National Univ. Hospital, Busan (Korea, Republic of)

    2004-08-01

    To evaluate the usefulness of multi-detector row helical CT (MDCT), multiplanar reformatted images for the noninvasive assessment of biliary stent patency, and for the planning for management in patients with a sele-expandable metallic stent due to malignant biliary obstruction. Among 90 consecutive patients, from August 1999 to July 2003, 26 cases in 23 patients with malignant biliary obstruction who underwent self-expandable metaIlic stent insertion in the biliary system and percutaneous transhepatic biliary drainage within 7 days after CT were enrolled in this study. On CT images, the complete and functional obstruction of the stent and the precise level of obstruction were evaluated. The presence of an enhancing intraluminal mass or wall thickening around stent was determined, and the causes of obstruction were evaluated. These findings were then compared with percutaneous transhepatic cholangiography. Multi-detector row helical CT correctly demonstrated the patency of a stent in 24 cases (92.3%). It was adequate in helping to depict the precise level of stent occlusion in 23 cases (88.5%). Multi-detector row helical CT also revealed the extent of tumor that represented as an enhancing intraluminal mass or wall thickening around the stent in 23 cases, and this was represented as complete obstruction on percutaneous transhepatic cholangiography. In the case of functional obstruction, MDCT predicted the possible cause of the obstruction. Multiplanar reformatted images of multi-detector row helical CT is a useful imaging modality for the noninvasive assessment of stent patency and the precise level of obstruction when stent obstruction is suspected in the patients with self-expandable metallic stent due to malignant biliary obstruction. It can also predict the possible cause of the obstruction and allows adequate planning for the medical management of such cases.

  1. Ectopic origin of bronchial arteries: assessment with multidetector helical CT angiography

    International Nuclear Information System (INIS)

    Hartmann, Ieneke J.C.; Remy-Jardin, Martine; Menchini, Laura; Teisseire, Antoine; Khalil, Chadi; Remy, Jacques

    2007-01-01

    The purpose of this study was to determine non-invasively the frequency of ectopic bronchial arteries (BA) (i.e., bronchial arteries originating at a level of the descending aorta other than T5-T6 or from any aortic collateral vessel) on multidetector-row CT angiograms (CTA) obtained in patients with hemoptysis. Over a 5-year period (2000-2005), 251 consecutive patients with hemoptysis underwent multidetector-row CT angiography of the thorax. From this population, 37 patients were excluded because of a suboptimal CTA examination (n = 19), the presence of extensive mediastinal disease (n = 15) or severe chest deformation (n = 3) precluding any precise analysis of the bronchial arteries at CTA. Our final study group included 214 patients who underwent a thin-collimated CT angiogram (contrast agent: 300 to 350 mg/ml) on a 4- (n = 56), 16- (n = 119) and 64- (n = 39) detector-row scanner. The site of origin and distribution of bronchial arteries were analyzed on transverse CT scans, maximum intensity projections and volume-rendered images. The site of the ostium of a bronchial artery was coded as orthotopic when the artery originated from the descending aorta between the levels of the fifth and sixth thoracic vertebrae; all other bronchial arteries were considered ectopic. From the studied population, 137 (64%) patients had only orthotopic bronchial arteries, whereas 77 patients (36%) had at least one bronchial artery of ectopic origin. A total of 147 ectopic arteries were depicted, originating as common bronchial trunks (n = 23; 19%) or isolated right or left bronchial arteries (n = 101; 81%). The most frequent sites of origin of the 124 ostiums were the concavity of the aortic arch (92/124; 74%), the subclavian artery (13/124; 10.5%) and the descending aorta (10/124; 8.5%). The isolated ectopic bronchial arteries supplied the ipsilateral lung in all but three cases. Bronchial artery embolization was indicated in 26 patients. On the basis of CTA information, (1

  2. Radiation dose from multidetector CT studies in children: results from the first Italian nationwide survey

    Energy Technology Data Exchange (ETDEWEB)

    Granata, Claudio [IRCCS Istituto Giannina Gaslini, Department of Radiology, Genoa (Italy); Origgi, Daniela; Palorini, Federica [Istituto Europeo di Oncologia, Department of Medical Physics, Milan (Italy); Matranga, Domenica [University of Palermo, Department of Sciences for Health Promotion and Mother and Child Care ' ' G. D' Alessandro' ' , Palermo (Italy); Salerno, Sergio [University of Palermo, Department of Medical and Forensic Biopathology and Biotechnologies, Section of Radiology, Palermo (Italy)

    2015-05-01

    Multidetector CT (MDCT) scanners have contributed to the widespread use of CT in paediatric imaging. However, concerns are raised for the associated radiation exposure. Very few surveys on radiation exposure from MDCT studies in children are available. The aim of this study was to outline the status of radiation exposure in children from MDCT practice in Italy. In this retrospective multicentre study we asked Italian radiology units with an MDCT scanner with at least 16 slices to provide dosimetric and acquisition parameters of CT examinations in three age groups (1-5, 6-10, 11-15 years) for studies of head, chest and abdomen. The dosimetric results were reported in terms of third-quartile volumetric CT dose index (CTDI{sub vol}) (mGy), size-specific dose estimate (SSDE) (mGy), dose length product (DLP) (mGy cm), and total DLP for multiphase studies. These results were compared with paediatric European and adult Italian published data. A multivariate analysis assessed the association of CTDI{sub vol} with patient characteristics and scanning modalities. We collected data from 993 MDCT examinations performed at 25 centres. For age groups 1-5 years, 6-10 years and 11-15 years, the CTDI{sub vol}, DLP and total DLP values were statistically significantly below the values observed in our analogous national survey in adults, although the difference decreased with increasing age. CTDI{sub vol} variability among centres was statistically significant (variance = 0.07; 95% confidence interval = 0.03-0.16; P < 0.001). This study reviewed practice in Italian centres performing paediatric imaging with MDCT scanners. The variability of doses among centres suggests that the use of standardised CT protocols should be encouraged. (orig.)

  3. Multidetector row CT of the brain and carotid artery: a correlative analysis

    International Nuclear Information System (INIS)

    Saba, L.; Montisci, R.; Sanfilippo, R.; Mallarini, G.

    2009-01-01

    Aim: To evaluate the association between types of carotid plaque, the presence of prior ischaemic events detectable with CT, and patient's symptoms. Materials and methods: Between January 2004 and May 2006, 112 patients were evaluated using multidetector row computed tomography angiography (MDCTA) of the carotid arteries and computed tomography (CT) of the brain. Carotid arteries were categorized by evaluating the degree of stenosis according to North American Symptomatic Carotid Endarterectomy Trial (NASCET) criteria, the type of plaque, and the presence of plaque ulceration. The brain was assessed via CT for the presence, type, and position of lesions. Chi-square tests, Student's t test, and simple logistic regression analysis were performed and the Cohen kappa test was applied for interobserver variability measurement. Results: The Chi-square test indicated a statistically significant association between the presence of fatty plaques (p = 0.005) and CT-detectable lesions in the brain (p = 0.004). Moreover, the number of patients with CT-detectable brain lesions was greater in patients with >70% stenosis than in those with 70% stenosis and symptoms (p = 0.041), and an inverse association between calcified plaque and symptoms (p = 0.009). Conclusion: MDCTA allows adequate evaluation of the type of plaque. The results of the present study indicate that there is an association between cerebral lesions, symptoms, and fatty plaque in the carotid artery. The degree of stenosis also correlated with cerebral lesions and symptoms. According to the obtained data, the type of carotid plaque should be included among primary parameters in the classification of patients' risk class.

  4. Suitability of helical multislice acquisition technique for routine unenhanced brain CT: an image quality study using a 16-row detector configuration

    Energy Technology Data Exchange (ETDEWEB)

    Hernalsteen, Danielle; Cosnard, Guy; Grandin, Cecile; Duprez, Thierry [Universite Catholique de Louvain, Cliniques Universitaires Saint-Luc, Department of Radiology and Medical Imaging, Brussels (Belgium); Robert, Annie [Public Health School, Universite Catholique de Louvain, Department of Epidemiologics and Medical Statistics, Brussels (Belgium); Vlassenbroek, Alain [CT Clinical Science, Philips Medical Systems, Cleveland, OH (United States)

    2007-04-15

    Subjective and objective image quality (IQ) criteria, radiation doses, and acquisition times were compared using incremental monoslice, incremental multislice, and helical multislice acquisition techniques for routine unenhanced brain computed tomography (CT). Twenty-four patients were examined by two techniques in the same imaging session using a 16-row CT system equipped with 0.75-width detectors. Contiguous ''native'' 3-mm-thick slices were reconstructed for all acquisitions from four detectors for each slice (4 x 0.75 mm), with one channel available per detector. Two protocols were tailored to compare: (1) one-slice vs four-slice incremental images; (2) incremental vs helical four-slice images. Two trained observers independently scored 12 subjective items of IQ. Preference for the technique was assessed by one-tailed t test and the interobserver variation by two-tailed t test. The two observers gave very close IQ scores for the three techniques without significant interobserver variations. Measured IQ parameters failed to reveal any difference between techniques, and an approximate half radiation dose reduction was obtained by using the full 16-row configuration. Acquisition times were cumulatively shortened by using the multislice and the helical modality. (orig.)

  5. Suitability of helical multislice acquisition technique for routine unenhanced brain CT: an image quality study using a 16-row detector configuration

    International Nuclear Information System (INIS)

    Hernalsteen, Danielle; Cosnard, Guy; Grandin, Cecile; Duprez, Thierry; Robert, Annie; Vlassenbroek, Alain

    2007-01-01

    Subjective and objective image quality (IQ) criteria, radiation doses, and acquisition times were compared using incremental monoslice, incremental multislice, and helical multislice acquisition techniques for routine unenhanced brain computed tomography (CT). Twenty-four patients were examined by two techniques in the same imaging session using a 16-row CT system equipped with 0.75-width detectors. Contiguous ''native'' 3-mm-thick slices were reconstructed for all acquisitions from four detectors for each slice (4 x 0.75 mm), with one channel available per detector. Two protocols were tailored to compare: (1) one-slice vs four-slice incremental images; (2) incremental vs helical four-slice images. Two trained observers independently scored 12 subjective items of IQ. Preference for the technique was assessed by one-tailed t test and the interobserver variation by two-tailed t test. The two observers gave very close IQ scores for the three techniques without significant interobserver variations. Measured IQ parameters failed to reveal any difference between techniques, and an approximate half radiation dose reduction was obtained by using the full 16-row configuration. Acquisition times were cumulatively shortened by using the multislice and the helical modality. (orig.)

  6. Estudio vascular renal por TC multidetector de 64 canales 64-Multidetector row CT for the Renal Vascular Study

    OpenAIRE

    Daniela Stoisa; Fabrizzio E. Galiano; Andrés Quaranta; Roberto L. Villavicencio

    2009-01-01

    Objetivo: Mostrar las diversas variantes anatómicas vasculares tanto arteriales como venosas en el estudio angiográfico renal por tomografìa computada multidetector (TCMD) de 64 canales, dada su implicancia en un eventual planeamiento quirúrgico. Material y métodos: Evaluamos retrospectivamente 26 estudios realizados con tomógrafo Philips Brilliance de 64 canales. Se obtuvieron secuencias sin contraste y postcontraste e.v. en fases arterial y venosa, administrado con bomba inyectora doble cab...

  7. Multidetector CT Findings and Differential Diagnoses of Malignant Pleural Mesothelioma and Metastatic Pleural Diseases in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yoon Kyung [Department of Radiology, Gachon University Gil Medical Center, Incheon 21565 (Korea, Republic of); Kim, Jeung Sook [Department of Radiology, Dongguk University Ilsan Hospital, Goyang 10326 (Korea, Republic of); Lee, Kyung Won [Department of Radiology, Seoul National University Bundang Hospital, Seongnam 13620 (Korea, Republic of); Yi, Chin A [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351 (Korea, Republic of); Koo, Jin Mo [Department of Radiology, Seoul National University College of Medicine, Seoul 03080 (Korea, Republic of); Jung, Soon-Hee [Department of Pathology, Yonsei University Wonju College of Medicine, Wonju 26426 (Korea, Republic of)

    2016-11-01

    To compare the multidetector CT (MDCT) features of malignant pleural mesothelioma (MPM) and metastatic pleural disease (MPD). The authors reviewed the MDCT images of 167 patients, 103 patients with MPM and 64 patients with MPD. All 167 cases were pathologically confirmed by sonography-guided needle biopsy of pleura, thoracoscopic pleural biopsy, or open thoracotomy. CT features were evaluated with respect to pleural effusion, pleural thickening, invasion of other organs, lung abnormality, lymphadenopathy, mediastinal shifting, thoracic volume decrease, asbestosis, and the presence of pleural plaque. Pleural thickening was the most common CT finding in MPM (96.1%) and MPD (93.8%). Circumferential pleural thickening (31.1% vs. 10.9%, odds ratio [OR] 3.670), thickening of fissural pleura (83.5% vs. 67.2%, OR 2.471), thickening of diaphragmatic pleura (90.3% vs. 73.4%, OR 3.364), pleural mass (38.8% vs. 23.4%, OR 2.074), pericardial involvement (56.3% vs. 20.3%, OR 5.056), and pleural plaque (66.0% vs. 21.9%, OR 6.939) were more frequently seen in MPM than in MPD. On the other hand, nodular pleural thickening (59.2% vs. 76.6%, OR 0.445), hilar lymph node metastasis (5.8% vs. 20.3%, OR 0.243), mediastinal lymph node metastasis (10.7% vs. 37.5%, OR 0.199), and hematogenous lung metastasis (9.7% vs. 29.2%, OR 0.261) were less frequent in MPM than in MPD. When we analyzed MPD from extrathoracic malignancy (EMPD) separately and compared them to MPM, circumferential pleural thickening, thickening of interlobar fissure, pericardial involvement and presence of pleural plaque were significant findings indicating MPM than EMPD. MPM had significantly lower occurrence of hematogenous lung metastasis, as compared with EMPD. Awareness of frequent and infrequent CT findings could aid in distinguishing MPM from MPD.

  8. Multidetector CT findings and differential diagnoses of malignant pleural mesothelioma and metastatic pleural diseases in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yoon Kyung [Dept. of Radiology, Gachon University Gil Medical Center, Incheon (Korea, Republic of); Kim, Jeung Sook [Dept. of Radiology, Dongguk University Ilsan Hospital, Goyang (Korea, Republic of); Lee, Kyung Won [Dept. of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Yi, Chin A [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Koo, Jin Mo [Dept. of Radiology, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Soon Hee [Dept. of Pathology, Yonsei University Wonju College of Medicine, Wonju (Korea, Republic of)

    2016-07-15

    To compare the multidetector CT (MDCT) features of malignant pleural mesothelioma (MPM) and metastatic pleural disease (MPD). The authors reviewed the MDCT images of 167 patients, 103 patients with MPM and 64 patients with MPD. All 167 cases were pathologically confirmed by sonography-guided needle biopsy of pleura, thoracoscopic pleural biopsy, or open thoracotomy. CT features were evaluated with respect to pleural effusion, pleural thickening, invasion of other organs, lung abnormality, lymphadenopathy, mediastinal shifting, thoracic volume decrease, asbestosis, and the presence of pleural plaque. Pleural thickening was the most common CT finding in MPM (96.1%) and MPD (93.8%). Circumferential pleural thickening (31.1% vs. 10.9%, odds ratio [OR] 3.670), thickening of fissural pleura (83.5% vs. 67.2%, OR 2.471), thickening of diaphragmatic pleura (90.3% vs. 73.4%, OR 3.364), pleural mass (38.8% vs. 23.4%, OR 2.074), pericardial involvement (56.3% vs. 20.3%, OR 5.056), and pleural plaque (66.0% vs. 21.9%, OR 6.939) were more frequently seen in MPM than in MPD. On the other hand, nodular pleural thickening (59.2% vs. 76.6%, OR 0.445), hilar lymph node metastasis (5.8% vs. 20.3%, OR 0.243), mediastinal lymph node metastasis (10.7% vs. 37.5%, OR 0.199), and hematogenous lung metastasis (9.7% vs. 29.2%, OR 0.261) were less frequent in MPM than in MPD. When we analyzed MPD from extrathoracic malignancy (EMPD) separately and compared them to MPM, circumferential pleural thickening, thickening of interlobar fissure, pericardial involvement and presence of pleural plaque were significant findings indicating MPM than EMPD. MPM had significantly lower occurrence of hematogenous lung metastasis, as compared with EMPD. Awareness of frequent and infrequent CT findings could aid in distinguishing MPM from MPD.

  9. Correlation of Color Doppler with Multidetector CT Angiography Findings in Carotid Artery Stenosis

    Directory of Open Access Journals (Sweden)

    Živorad N. Savic

    2010-01-01

    Full Text Available The aim of this paper was to examine the correlation between the Color Doppler ultrasound (CD-US and multidetector CT angiography (MDCTA diagnostic methods, and to define the degree and extent of stenosis in patients with internal carotid artery stenosis. This was a cross-sectional study with a consecutive series of patients. All US examinations were always carried out by the same physician-angiologist, while all CT examinations were always carried out by the same physician-radiologist. Both worked independently from each other. The stenosis area was measured at the narrowest point by NASCET criteria for US/CT. Peak systolic velocity (PSV over 210 cm/sec and end diastolic velocity (EDV over 110 cm/sec criteria were applied for stenoses with lumen narrowed over 70%, while PSV under 130 cm/sec and EDV under 100 cm/sec criteria were applied for those with lumen narrowed under 70%. A total of 124 carotid arteries were observed; namely, 89 narrowed and 68 surgically treated. All patients were reviewed by US and then by MDCTA; patients with 70–99% stenosis underwent surgery. The correlation coefficient between stenosis degree measured by US and MDCTA was 0.922; p 0.05. The US and CT matching level for stenoses from 70 to 99% was very high (κ = 0.778, p < 0.01. In conclusion, there is a highly significant statistical correlation among both diagnostic methods when measuring stenosis degree and extent. US is more dependent on the physician, while MDCTA is more objective and independent from the physician. We think it would be appropriate to undertake an MDCTA exam for those patients who are candidates for carotid endarterectomy.

  10. Diagnosis of deep vein thrombosis using multi-detector helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Masashi; Minamiguchi, Hiroki; Sahara, Shinya [Wakayama Medical Coll. (Japan)] [and others

    2002-11-01

    The purpose of this study was to evaluate the usefulness of multi-detector helical CT (MDHCT) with contrast medium in the diagnosis of deep vein thrombosis (DVT). The bilateral veins of the dorsal pedis in 45 patients (12 men, 33 women; average age, 64 years) under clinical suspicion of DVT were first punctured using 22-G needles. Then CT scanning from the level of the foot to the inferior vena cava was started 20 sec after the initial injection of 200 mL of dilute contrast medium (50 mL nonionic iodinated contrast medium of 300 mgI/mL and 150 mL saline) at a rate of 5 mL/sec. Two patients were excluded because of unsuccessful venous puncture. The average scanning time in 43 patients was 38.5{+-}7.9 seconds. Images of veins from the foot to the inferior vena cava were clearly demonstrated in each case. MDHCT showed DVT in 32 cases and patent deep vein in 11 cases. Simultaneous venography of the lower extremity in 18 patients clearly visualized DVT at the same level detected by contrast MDHCT. MDHCT for the diagnosis of DVT has the advantages of wider scanning rage, shorter scanning time, and finer Z-axis resolution than the other diagnostic modalities. (author)

  11. Intrinsic carpal ligaments on MR and multidetector CT arthrography: comparison of axial and axial oblique planes

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ryan K.L.; Griffith, James F.; Ng, Alex W.H.; Law, Eric K.C. [The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince Of Wales Hospital, Hong Kong (China); Tse, W.L.; Wong, Clara W.Y.; Ho, P.C. [The Chinese University of Hong Kong, Department of Orthopedics and Traumatology, Prince Of Wales Hospital, Hong Kong (China)

    2017-03-15

    To compare axial and oblique axial planes on MR arthrography (MRA) and multidetector CT arthrography (CTA) to evaluate dorsal and volar parts of scapholunate (SLIL) and lunotriquetral interosseous (LTIL) ligaments. Nine cadaveric wrists of five male subjects were studied. The visibility of dorsal and volar parts of the SLIL and LTIL was graded semi-quantitatively (good, intermediate, poor) on MRA and CTA. The presence of a ligament tear was determined on arthrosocopy and sensitivity, specificity and accuracy of tear detection were calculated. Oblique axial imaging was particularly useful for delineating dorsal and volar parts of the LTIL on MRA with overall 'good' visibility increased from 11 % to 78 %. The accuracy of MRA and CTA in revealing SLIL and LTIL tear was higher using the oblique axial plane. The overall accuracy for detecting SLIL tear on CTA improved from 94 % to 100 % and from 89 % to 94 % on MRA; the overall accuracy of detecting LTIL tear on CTA improved from 89 % to 100 % and from 72 % to 89 % on MRA Oblique axial imaging during CT and MR arthrography improves detection of tears in the dorsal and volar parts of both SLIL and LTIL. (orig.)

  12. Diagnosis of deep vein thrombosis using multi-detector helical CT

    International Nuclear Information System (INIS)

    Kimura, Masashi; Minamiguchi, Hiroki; Sahara, Shinya

    2002-01-01

    The purpose of this study was to evaluate the usefulness of multi-detector helical CT (MDHCT) with contrast medium in the diagnosis of deep vein thrombosis (DVT). The bilateral veins of the dorsal pedis in 45 patients (12 men, 33 women; average age, 64 years) under clinical suspicion of DVT were first punctured using 22-G needles. Then CT scanning from the level of the foot to the inferior vena cava was started 20 sec after the initial injection of 200 mL of dilute contrast medium (50 mL nonionic iodinated contrast medium of 300 mgI/mL and 150 mL saline) at a rate of 5 mL/sec. Two patients were excluded because of unsuccessful venous puncture. The average scanning time in 43 patients was 38.5±7.9 seconds. Images of veins from the foot to the inferior vena cava were clearly demonstrated in each case. MDHCT showed DVT in 32 cases and patent deep vein in 11 cases. Simultaneous venography of the lower extremity in 18 patients clearly visualized DVT at the same level detected by contrast MDHCT. MDHCT for the diagnosis of DVT has the advantages of wider scanning rage, shorter scanning time, and finer Z-axis resolution than the other diagnostic modalities. (author)

  13. Optimal reconstructed section thickness for the detection of liver lesions with multidetector CT

    International Nuclear Information System (INIS)

    Soo, G.; Lau, K.K.; Yik, T.; Kutschera, P.

    2010-01-01

    Aim: To evaluate the impact of different reconstructed section thicknesses on liver lesion detection using multidetector computed tomography (CT). Methods: Fifty-three patients were examined using a 16-section CT machine with axial reconstructions provided at 2.5, 5, 7.5, and 10 mm section thicknesses. Images of different reconstructed section thicknesses from different patients were presented in random order to three independent, blinded radiologists for review at multiple sessions. All images were then reviewed by three radiologists in a common session. Consensus was reached following review of the previous interpretation results and results of follow-up imaging regarding the number of true liver lesions (n = 101) for comparison. Results: Mean detection rates were as follows: 93/101 lesions detected with the 2.5 mm section thickness, 98/101 lesions detected at the 5 mm section thickness, 78/101 lesions detected at the 7.5 mm section thickness, and 54/101 lesions detected at the 10 mm section thickness. Lesions missed at the 2.5 mm section thickness were due to masking by image noise. There was particular difficulty detecting subcapsular lesions and lesions adjacent to fissures or the gall bladder at the 7.5 mm and 10 mm section thicknesses. Conclusion: The optimal reconstructed section thickness for lesion detection in the liver was 5 mm.

  14. Optimised low-dose multidetector CT protocol for children with cranial deformity

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, Jose Luis [Complejo Hospitalario Universitario de Vigo, Department of Radiology, Vigo, Pontevedra (Spain); Pombar, Miguel Angel [Complejo Hospitalario Universitario de Santiago, Department of Radiophysics, Santiago de Compostela, La Coruna (Spain); Pumar, Jose Manuel [Complejo Hospitalario Universitario de Santiago, Department of Radiology, Santiago de Compostela, La Coruna (Spain); Campo, Victor Miguel del [Complejo Hospitalario Universitario de Vigo, Department of Public Health, Vigo, Pontevedra (Spain)

    2013-08-15

    To present an optimised low-dose multidetector computed tomography (MDCT) protocol for the study of children with cranial deformity. Ninety-one consecutive MDCT studies were performed in 80 children. Studies were performed with either our standard head CT protocol (group 1, n = 20) or a low-dose cranial deformity protocol (groups 2 and 3). Group 2 (n = 38), initial, and group 3 (n = 33), final and more optimised. All studies were performed in the same 64-MDCT equipment. Cranial deformity protocol was gradationally optimised decreasing kVp, limiting mA range, using automatic exposure control (AEC) and increasing the noise index (NI). Image quality was assessed. Dose indicators such us CT dose index volume (CTDIvol), dose-length product (DLP) and effective dose (E) were used. The optimised low-dose protocol reached the following values: 80 kVp, mA range: 50-150 and NI = 23. We achieved a maximum dose reduction of 10-22 times in the 1- to 12-month-old cranium in regard to the 2004 European guidelines for MDCT. A low-dose MDCT protocol that may be used as the first diagnostic imaging option in clinically selected patients with skull abnormalities. (orig.)

  15. Multi-detector CT coronary angiographic findings of coronary-to-pulmonary artery fistula

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jae Seok; Park, Eun Ah; Lim, Ji Yeon; Lee, Whal [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Park, Jae Hyung [Dept. of Radiology, Myongji Hospital, Seonam University College of Medicine, Goyang (Korea, Republic of)

    2017-01-15

    To evaluate multi-detector CT (MDCT) coronary angiographic findings of coronary-to-pulmonary artery fistula (CPAF). We retrospectively reviewed images of patients with CPAF from the coronary CT angiography (CCTA) database obtained with a 64-channel MDCT between January 2008 and March 2011. We analyzed the CCTA findings for feeding arteries, fistula, association with peripulmonary arterial aneurysms, and the presence of communication between the CPAF and bronchial arteries. Fifty-five of the 15042 (0.37%) patients were diagnosed with CPAFs. The feeding artery was single (n = 18) or multiple (n = 37). The fistula had a single drainage site (n = 54) or multiple drainage sites (n = 1). The mean diameter of the fistulous opening was 2.7 ± 1.4 mm. A peripulmonary arterial aneurysm was present in 24 (44%) patients. Communication between CPAF and bronchial arteries was present in eight (14.5%) patients. MDCT coronary angiography can provide comprehensive morphologic details on CPAF and may help in presurgical or preinterventional planning.

  16. Detection of pulmonary metastatic nodules: usefulness of low-dose multidetector CT in comparison with chest radiograph

    International Nuclear Information System (INIS)

    Kim, Ki Nam; Lee, Ki Nam; Yang, Doo Kyung; Lee, Soo Keol

    2006-01-01

    We wanted to evaluate the usefulness of low-dose multidetector CT for the detection and follow-up of pulmonary metastatic nodules in patients suffering with malignancy. We retrospectively reviewed the conventional chest radiographs and low-dose multidetector CT (low-dose CT) scans of 81 patients who had been under the diagnosis of malignancy. We reviewed the detection of pulmonary nodules and we counted the number of nodules detected by each method. The nodules were confirmed by surgical operation and by the radiologic criteria. The accuracy, sensitivity, specificity and positive and negative predictive values of each method for detecting metastatic nodules were compared with χ 2 tests. Low-dose CT depicted more nodules than did chest radiograph, and the indeterminate nodules seen on chest radiograph may be clearly benign on low-dose CT (eg. calcified granulomas or bony lesions). The accuracy of low-dose CT (75.3%) was significantly higher than that of chest radiograph (49.4%) for the detection for metastatic nodules (ρ < 0.05). Low-dose CT may provide better information than does chest radiograph for diagnosing pulmonary metastasis

  17. How to interpret an unenhanced CT Brain scan. Part 1: Basic principles of Computed Tomography and relevant neuroanatomy

    Directory of Open Access Journals (Sweden)

    Thomas Osborne

    2016-08-01

    Full Text Available The aim of this article is to: Cover the basics of Computed Tomography (CT Brain imaging. Review relevant CT neuroanatomy. A CT image is produced by firing x-rays at a moving object which is then detected by an array of rotating detectors (Figure 1. The detected x-rays are then converted into a computerised signal which is used to produce a series of cross sectional images.

  18. Effectiveness of thin-slice axial images of multidetector row CT for visualization of bronchial artery before bronchial arterial embolization

    International Nuclear Information System (INIS)

    Shida, Yoshitaka; Hasuo, Kanehiro; Aibe, Hitoshi; Kubo, Yuko; Terashima, Kotaro; Kinjo, Maya; Kamano, H.; Yoshida, Atsuko

    2008-01-01

    We assessed the ability of visualization of bronchial artery (BA) by using thin-slice axial images of 4-detector multidetector row CT in 65 patients with hemoptysis. In all patients, the origins of BA were well identified with observation of consecutive axial images with 1 mm thickness by paging method and bronchial arterial embolization (BAE) was performed successfully. Thin-slice axial images were considered to be useful to recognize BA and to perform BAE in patients with hemoptysis. (author)

  19. Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Dae Kyo; Lee, Sang Chul; Huh, Kyung Hoe; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2012-06-15

    The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. The effective dose was the highest for Somatom Sensation 10 (425.84 {mu}Sv), followed by AZ3000CT (332.4 {mu}Sv), Somatom Emotion 6 (199.38 {mu}Sv), and 3D eXaM (111.6 {mu}Sv); it was the lowest for Implagraphy (83.09 {mu}Sv). The CBCT showed significant variation in dose level with different device. The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

  20. Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

    International Nuclear Information System (INIS)

    Jeong, Dae Kyo; Lee, Sang Chul; Huh, Kyung Hoe; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul

    2012-01-01

    The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. The effective dose was the highest for Somatom Sensation 10 (425.84 μSv), followed by AZ3000CT (332.4 μSv), Somatom Emotion 6 (199.38 μSv), and 3D eXaM (111.6 μSv); it was the lowest for Implagraphy (83.09 μSv). The CBCT showed significant variation in dose level with different device. The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

  1. Multidetector CT: a new gold standard in the diagnosis of pulmonary embolism? State of the art and diagnostic algorithms

    International Nuclear Information System (INIS)

    Russo, Vincenzo; Piva, Tommaso; Lovato, Luigi; Fattori, Rossella; Gavelli, Giampaolo

    2005-01-01

    Purpose: From the early 90s, spiral CT technology has considerably changed the diagnostic capability of Pulmonary Embolism (PE), giving a direct vision of intravascular thrombi. Further technological progress has straightened its diagnostic impact leading to an essential role in clinical practice. The advent of Multi-Detector CT (MDCT) has subsequently increased the reliability of this technique to the point of undermining the role of pulmonary angiography as the gold standard and occupying a central position in diagnostic algorithms. The aim of this paper is to appraise this evolution by means of a meta-analysis of the relevant literature from 1995 to 2004. Results: The review of the literature showed the sensitivity and specificity of CT to have increased from 37-94% and 91-100% (single detector CT) to 87-94% and 94-100% (4-channel multidetector CT), especially thanks to the possibility of depicting subsegmental clots, with an interobserver agreement of 0.63-0.94 (k). Conclusions: CT is one of the most reliable and effective methods in the diagnosis is PE, with the advantage of being extremely fast and providing alternative diagnoses. Recent improvements in MDCT technology confers the highest value of diagnostic accuracy with respect to other imaging modalities such as scintigraphy, angiography, MRI, D-dimer essay and Doppler US [it

  2. Two examples of indication specific radiation dose calculations in dental CBCT and Multidetector CT scanners.

    Science.gov (United States)

    Stratis, Andreas; Zhang, Guozhi; Lopez-Rendon, Xochitl; Politis, Constantinus; Hermans, Robert; Jacobs, Reinhilde; Bogaerts, Ria; Shaheen, Eman; Bosmans, Hilde

    2017-09-01

    To calculate organ doses and estimate the effective dose for justification purposes in patients undergoing orthognathic treatment planning purposes and temporal bone imaging in dental cone beam CT (CBCT) and Multidetector CT (MDCT) scanners. The radiation dose to the ICRP reference male voxel phantom was calculated for dedicated orthognathic treatment planning acquisitions via Monte Carlo simulations in two dental CBCT scanners, Promax 3D Max (Planmeca, FI) and NewTom VGi evo (QR s.r.l, IT) and in Somatom Definition Flash (Siemens, DE) MDCT scanner. For temporal bone imaging, radiation doses were calculated via MC simulations for a CBCT protocol in NewTom 5G (QR s.r.l, IT) and with the use of a software tool (CT-expo) for Somatom Force (Siemens, DE). All procedures had been optimized at the acceptance tests of the devices. For orthognathic protocols, dental CBCT scanners deliver lower doses compared to MDCT scanners. The estimated effective dose (ED) was 0.32mSv for a normal resolution operation mode in Promax 3D Max, 0.27mSv in VGi-evo and 1.18mSv in the Somatom Definition Flash. For temporal bone protocols, the Somatom Force resulted in an estimated ED of 0.28mSv while for NewTom 5G the ED was 0.31 and 0.22mSv for monolateral and bilateral imaging respectively. Two clinical exams which are carried out with both a CBCT or a MDCT scanner were compared in terms of radiation dose. Dental CBCT scanners deliver lower doses for orthognathic patients whereas for temporal bone procedures the doses were similar. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  3. Venous variants and anomalies on routine abdominal multi-detector row CT

    International Nuclear Information System (INIS)

    Koc, Zafer; Ulusan, Serife; Oguzkurt, Levent; Tokmak, Naime

    2007-01-01

    Objective: This study aims to determine the types and prevalence rates of anatomic variations of the hepatic veins, portal vein, inferior vena cava and renal veins, and to establish statistical correlations between various anomalies and frequency differences between male and female using multi-detector row computed tomography (CT). Materials and methods: One thousand one hundred and twenty patients (588 men, 532 women) were evaluated with routine abdominal CT. Frequencies of different variants were noted and compared, and correlations between three categories of variation were tested. Results: In total, 1261 abdominal vein variants and anomalies were identified in 756 (67.5%) of 1120 patients. Six hundred and forty-two hepatic vein variants were detected in 468 (41.8%) patients. One or more inferior right hepatic veins were identified in 356 (31.8%) individuals, and tributary hepatic veins were detected in 147 (13.1%) patients. Portal vein variations and anomalies were observed in 307 (27.4%) cases. The most frequent of these was trifurcation (139 patients, 12.4%). A total of 311 inferior vena cava and renal vein variants were identified in 258 (23%) cases. Six patients (0.5%) exhibited inferior vena cava anomalies, 62 (5.5%) had circumaortic renal veins, 53 (4.7%) had retroaortic renal veins, and 210 (18.8%) had multiple renal veins. Conclusion: The prevalence of abdominal vein variations is high, and routine abdominal CT demonstrates these abnormalities very well. The data suggest that hepatic vein variants and multiple right renal veins are more frequent in women than in men, and that hepatic vein variation is correlated with portal vein variation

  4. Venous variants and anomalies on routine abdominal multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Koc, Zafer [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey)]. E-mail: koczafer@gmail.com; Ulusan, Serife [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey); Oguzkurt, Levent [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey); Tokmak, Naime [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey)

    2007-02-15

    Objective: This study aims to determine the types and prevalence rates of anatomic variations of the hepatic veins, portal vein, inferior vena cava and renal veins, and to establish statistical correlations between various anomalies and frequency differences between male and female using multi-detector row computed tomography (CT). Materials and methods: One thousand one hundred and twenty patients (588 men, 532 women) were evaluated with routine abdominal CT. Frequencies of different variants were noted and compared, and correlations between three categories of variation were tested. Results: In total, 1261 abdominal vein variants and anomalies were identified in 756 (67.5%) of 1120 patients. Six hundred and forty-two hepatic vein variants were detected in 468 (41.8%) patients. One or more inferior right hepatic veins were identified in 356 (31.8%) individuals, and tributary hepatic veins were detected in 147 (13.1%) patients. Portal vein variations and anomalies were observed in 307 (27.4%) cases. The most frequent of these was trifurcation (139 patients, 12.4%). A total of 311 inferior vena cava and renal vein variants were identified in 258 (23%) cases. Six patients (0.5%) exhibited inferior vena cava anomalies, 62 (5.5%) had circumaortic renal veins, 53 (4.7%) had retroaortic renal veins, and 210 (18.8%) had multiple renal veins. Conclusion: The prevalence of abdominal vein variations is high, and routine abdominal CT demonstrates these abnormalities very well. The data suggest that hepatic vein variants and multiple right renal veins are more frequent in women than in men, and that hepatic vein variation is correlated with portal vein variation.

  5. Virtual non-contrast computer tomography (CT) with spectral CT as an alternative to conventional unenhanced CT in the assessment of gastric cancer.

    Science.gov (United States)

    Tian, Shi-Feng; Liu, Ai-Lian; Wang, He-Qing; Liu, Jing-Hong; Sun, Mei-Yu; Liu, Yi-Jun

    2015-01-01

    The purpose of this study was to evaluate computed tomography (CT) virtual non-contrast (VNC) spectral imaging for gastric carcinoma. Fifty-two patients with histologically proven gastric carcinomas underwent gemstone spectral imaging (GSI) including non-contrast and contrast-enhanced hepatic arterial, portal venous, and equilibrium phase acquisitions prior to surgery. VNC arterial phase (VNCa), VNC venous phase (VNCv), and VNC equilibrium phase (VNCe) images were obtained by subtracting iodine from iodine/water images. Images were analyzed with respect to image quality, gastric carcinoma-intragastric water contrast-to-noise ratio (CNR), gastric carcinoma-perigastric fat CNR, serosal invasion, and enlarged lymph nodes around the lesions. Carcinoma-water CNR values were significantly higher in VNCa, VNCv, and VNCe images than in normal CT images (2.72, 2.60, 2.61, respectively, vs 2.35, p≤0.008). Carcinoma- perigastric fat CNR values were significantly lower in VNCa, VNCv, and VNCe images than in normal CT images (7.63, 7.49, 7.32, respectively, vs 8.48, pVNC arterial phase images may be a surrogate for conventional non-contrast CT images in gastric carcinoma evaluation.

  6. Cirsoid Aneurysm of Coronary Arteries Associated with Arterioventricular Fistula Evaluated by 64-Multidetector CT Coronary Angiography: Depiction of a Case

    International Nuclear Information System (INIS)

    Marrone, Gianluca; Mamone, Giuseppe; Milazzo, Mariapina; Caruso, Settimo; Baravoglia, Cesar Hernandez; Vitulo, Patrizio; Gridelli, Bruno; Luca, Angelo

    2009-01-01

    A female patient with severe pulmonary hypertension was admitted for lung transplant evaluation. As an incidental finding, the chest CT showed diffuse and dilated coronaries, not detected at previous echocardiography. A coronary CT angiography was then performed using a 64-multidetector computed tomography (MDCT) scanner to better evaluate the coronary tree. The images obtained after postprocessing demonstrated tremendously aneurysmatic and tortuous coronary arteries and the presence of a septal branch deepening into the myocardium and penetrating the right ventricle cavity, forming an abnormal arterioventricular fistula. A causal relation between the aneurysms and the fistula is suspected.

  7. The postprocessing techniques in renal artery reconstructions and clinical application with multidetector spiral CT angiography

    International Nuclear Information System (INIS)

    Yu Yuanxin; Liang Changhong; Zhang Zhonglin; Xie Shufei; Liu Yubao; Tang Xiangzhou

    2005-01-01

    Objective: To investigate the value and predominance for imaging postprocessing techniques of renal artery variation and lesions by multidetector spiral CT angiography. Methods: 51 patients with renal artery disease including 12 artery variation, 27 artery stenosis, 3 renal anenrysm, 3 thrombosis of renal artery and 3 dissecting aneurysm of renal artery by SSD, MIP and CPR were enrolled. The effectiveness of these imaging postprocessing methods was compared, 29 of them were confirmed by DSA and 3 by operation, others were checked by MRA and follow up. Results: All abnormalities and diseases were cleariy displayed. The specificity and sensitivity were 100% respectively. In the all imaging postprocessing techniques, MPR can clearly display the calcification of the arteries, stenosis, embolism, aneurysm but do not display the anatomy satisfactorily. MIP can not only clearly display the anatomy but display the different configurations. VR can display the artery figures but can not display the information of lumen of blood vessels. SSD can display the complex vessel anatomy but it was influenced by its threshold selection. CPR can spread and display directly the tortuous renal artery and measure the section area of stenosis. Conclusions: MSCTA is helpful to accurately display the renal artery variation and lesions. Both MIP and VR are the best choice to illustrate the renal artery abnormalities. And MPR and SSD are assistant in the diagnosis of' renal artery lesions. (authors)

  8. Chronic intestinal pseudo-obstruction in adult patients: multidetector row helical CT features

    International Nuclear Information System (INIS)

    Merlin, Aurelie; Soyer, Philippe; Boudiaf, Mourad; Hamzi, Lounis; Rymer, Roland

    2008-01-01

    Chronic intestinal pseudo-obstruction (CIPO) is a rare condition due to severe gastrointestinal motility disorder. Adult patients with CIPO experience symptoms of mechanical obstruction, but reliable clinical signs that may help distinguish between actual mechanical obstruction and CIPO are lacking. Additionally, abdominal plain films that commonly show bowel dilatation with air-fluid levels do not reach acceptable degrees of specificity to exclude actual obstruction. Therefore, most adult patients with CIPO usually undergo multiple and often fruitless surgery, often leading to repeated bowel resections before diagnosis is made. In these patients who present with abdominal signs mimicking symptoms that would warrant surgical exploration, multidetector-row helical CT (MDCT) is helpful to resolve this diagnostic dilemma. MDCT shows a diffusely distended bowel and helps to rule out a mechanical cause of obstruction, thus suggesting CIPO and obviating the need for unnecessary laparotomy. In adult patients with CIPO, MDCT may show pneumatosis intestinalis, pneumoperitoneum or intussusception. However, these conditions generally do not require surgery in patients with CIPO. This pictorial essay presents the more and less common MDCT features of CIPO in adult patients, to make the reader more familiar with this disease. (orig.)

  9. Radiation dose of digital tomosynthesis for sinonasal examination: comparison with multi-detector CT.

    Science.gov (United States)

    Machida, Haruhiko; Yuhara, Toshiyuki; Tamura, Mieko; Numano, Tomokazu; Abe, Shinji; Sabol, John M; Suzuki, Shigeru; Ueno, Eiko

    2012-06-01

    Using an anthropomorphic phantom, we have investigated the feasibility of digital tomosynthesis (DT) of flat-panel detector (FPD) radiography to reduce radiation dose for sinonasal examination compared to multi-detector computed tomography (MDCT). A female Rando phantom was scanned covering frontal to maxillary sinus using the clinically routine protocol by both 64-detector CT (120 kV, 200 mAs, and 1.375-pitch) and DT radiography (80 kV, 1.0 mAs per projection, 60 projections, 40° sweep, and posterior-anterior projections). Glass dosimeters were used to measure the radiation dose to internal organs including the thyroid gland, brain, submandibular gland, and the surface dose at various sites including the eyes during those scans. We compared the radiation dose to those anatomies between both modalities. In DT radiography, the doses of the thyroid gland, brain, submandibular gland, skin, and eyes were 230 ± 90 μGy, 1770 ± 560 μGy, 1400 ± 80 μGy, 1160 ± 2100 μGy, and 112 ± 6 μGy, respectively. These doses were reduced to approximately 1/5, 1/8, 1/12, 1/17, and 1/290 of the respective MDCT dose. For sinonasal examinations, DT radiography enables dramatic reduction in radiation exposure and dose to the head and neck region, particularly to the lens of the eye. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  10. Anterior atlantodental and posterior atlantodental intervals on plain radiography, multidetector CT, and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Seung Woo; Ryu, Jeong Ah; Park, Dong Woo [Dept. of Radiology, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri (Korea, Republic of); Yoon, Ki Bo; Lee, Seung Hun; Joo, Kyung Bin [Dept. of Radiology, Hanyang University Seoul Hospital, Hanyang University College of Medicine, Seoul(Korea, Republic of)

    2015-01-15

    To determine the normal values of the anterior atlantodental interval (AADI) and posterior atlantodental interval (PADI) on plain radiography, multidetector CT (MDCT) and MRI, as well as the dural sac width and spinal cord diameter at the atlantoaxial joint level on MRI. In total, 60 subjects underwent plain radiography, MRI and MDCT. We obtained values for AADI and PADI on plain radiography, MDCT, and MRI, and for dural sac width and spinal cord diameter on MRI. Two radiologists independently measured each value and a consensus was reached. The average AADI was 1.5 +/- 0.5 mm on plain radiography, 1.4 +/- 0.3 mm on MDCT, and 1.6 +/- 0.5 mm on MRI. The average PADI was 20.6 +/- 2.4 mm on plain radiography, 18.0 +/- 2.1 mm on MDCT, and 17.7 +/- 1.9 mm on MRI. The dural sac width was 13.7 +/- 1.8 mm, and the spinal cord diameter was 7.8 +/- 0.7 mm. Interobserver agreement was 0.701-0.927 and intraobserver agreement was 0.681-0.937. AADI values obtained on MDCT are significantly lower than those obtained on plain radiography or MRI. PADI values obtained on plain radiography are significantly higher than those obtained on MDCT or MRI. The dural sac width is most closely correlated with PADI values on MDCT. PADI seems to be easier to measure, more relevant, and clinically useful than AADI.

  11. Multidetector CT evaluation of total anomalous pulmonary venous connections: comparison with echocardiography

    International Nuclear Information System (INIS)

    Oh, Ki Ho; Choo, Ki Seok; Lim, Soo Jin; Lee, Hyoung Doo; Park, Ji Ae; Jo, Min Jung; Sung, Si Chan; Chang, Yun Hee; Jeong, Dong Wook; Kim, Siho

    2009-01-01

    Although echocardiography is the first-line imaging modality in the diagnosis of total anomalous pulmonary venous connection (TAPVC), multidetector CT (MDCT) could have advantages in the diagnosis of TAPVC in certain cases. To compare MDCT with echocardiography in the evaluation of TAPVC. Enrolled in the study were 23 patients with surgically proven TAPVC. The echocardiography and MDCT findings were independently interpreted by a paediatric cardiologist and cardiac radiologist in terms of: (1) the drainage site of the common pulmonary vein, (2) stenosis of the vertical vein, and (3) the course of the atypical vessel into the systemic vein in the case of vertical vein stenosis. The findings from both modalities were correlated with the results obtained at surgery (n=22) or autopsy (n=1). In all patients, MDCT correctly depicted the drainage site of the common pulmonary vein, stenosis of the vertical vein and the course of the atypical vessel into the systemic vein (sensitivity 100%, specificity 100%). The specificity of echocardiography was 100% for the three defined findings. The sensitivity of echocardiography, however, was 87%, 71% and 0%, respectively. MDCT can facilitate the diagnosis of TAPVC in certain cases. (orig.)

  12. Impact of multidetector CT-angiography on the emergency management of severe hemoptysis

    Energy Technology Data Exchange (ETDEWEB)

    Chalumeau-Lemoine, Ludivine [Service de Pneumologie et Réanimation, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Khalil, Antoine, E-mail: antoine_khalil@yahoo.fr [Service de Radiologie, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Pathological Angiogenesis and Vessel Normalization, Center for Interdisciplinary Research in Biology, CNRS UMR 7241/INSERM U1050, Collège de France, Paris (France); Prigent, Hélène [Service de Pneumologie et Réanimation, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Carette, Marie-France [Service de Radiologie, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Université Pierre et Marie Curie, Paris VI (France); Fartoukh, Muriel [Service de Pneumologie et Réanimation, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Université Pierre et Marie Curie, Paris VI (France); Parrot, Antoine [Service de Pneumologie et Réanimation, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France)

    2013-11-01

    Background: Multidetector CT-angiography (MDCTA) is commonly used in patients with severe haemoptysis requiring admission to intensive care unit. However, the impact of MDCTA on the management of severe haemoptysis in emergency setting is poorly evaluated. Methods: We prospectively compared data provided by clinical bedside evaluation (clinical examination, chest-X-ray and fiberoptic bronchoscopy) to MDCTA data in terms of lateralization, location of the bleeding site, etiology as well as impact on the treatment choice. Results: Over a 13-month period, 87 patients (men n = 58, median age = 61 years, median haemoptysis expectorated volume = 180 mL) were included. Etiology was mainly (67%) bronchiectasis, tuberculosis sequelae and tumor. MDCTA and clinical bedside evaluation were equally effective in determining lateralization (87.4% and 93.1%, respectively, p = 0.23) and location (85% and 82.7%, respectively, p = 0.82) of the bleeding site. MDCTA was significantly more accurate than the clinical bedside strategy in determining the haemoptysis cause (86% and 70%, respectively, p = 0.007). Moreover, MDCTA suggested the involvement of systemic arteries as bleeding mechanism in 92% of cases, leading to the modification of the treatment initially considered after bedside evaluation in 21.8% of patients. Conclusion: MDCTA provides useful information for the management of patients with severe haemoptysis, especially in the treatment choice. Thus, in the absence of emergency fiberoptic bronchoscopy (FOB) requirement for airways management, MDCTA should be the first-line procedure performed in emergency clinical setting.

  13. Impact of multidetector CT-angiography on the emergency management of severe hemoptysis

    International Nuclear Information System (INIS)

    Chalumeau-Lemoine, Ludivine; Khalil, Antoine; Prigent, Hélène; Carette, Marie-France; Fartoukh, Muriel; Parrot, Antoine

    2013-01-01

    Background: Multidetector CT-angiography (MDCTA) is commonly used in patients with severe haemoptysis requiring admission to intensive care unit. However, the impact of MDCTA on the management of severe haemoptysis in emergency setting is poorly evaluated. Methods: We prospectively compared data provided by clinical bedside evaluation (clinical examination, chest-X-ray and fiberoptic bronchoscopy) to MDCTA data in terms of lateralization, location of the bleeding site, etiology as well as impact on the treatment choice. Results: Over a 13-month period, 87 patients (men n = 58, median age = 61 years, median haemoptysis expectorated volume = 180 mL) were included. Etiology was mainly (67%) bronchiectasis, tuberculosis sequelae and tumor. MDCTA and clinical bedside evaluation were equally effective in determining lateralization (87.4% and 93.1%, respectively, p = 0.23) and location (85% and 82.7%, respectively, p = 0.82) of the bleeding site. MDCTA was significantly more accurate than the clinical bedside strategy in determining the haemoptysis cause (86% and 70%, respectively, p = 0.007). Moreover, MDCTA suggested the involvement of systemic arteries as bleeding mechanism in 92% of cases, leading to the modification of the treatment initially considered after bedside evaluation in 21.8% of patients. Conclusion: MDCTA provides useful information for the management of patients with severe haemoptysis, especially in the treatment choice. Thus, in the absence of emergency fiberoptic bronchoscopy (FOB) requirement for airways management, MDCTA should be the first-line procedure performed in emergency clinical setting

  14. Multidetector CT enteroclysis: comparison of the reading performance for axial and coronal views

    International Nuclear Information System (INIS)

    Schmidt, Sabine; Chalaron, Marc; Schnyder, Pierre; Denys, Alban; Chevallier, Patrick; Bessoud, Bertrand; Verdun, Francis R.; Frascarolo, Philippe

    2005-01-01

    The purpose of this study was to compare the diagnostic performance of axial and coronal views in multidetector CT enteroclysis (MDCTE). We retrospectively evaluated 48 patients with pathological correlation investigated by MDCTE for small bowel disorders. After nasojejunal administration of 2 l of 5% methylcellulose axial arterial and venous acquisition of MDCTE was followed by coronal reconstructions using equal slice thicknesses of 2.5 mm with 2 mm increments. Spatial resolution of both planes was evaluated by phantom. Three radiologists independently read axial and coronal images concerning 12 pathological features. The interobserver agreement and time of reading was calculated. Sensitivity and specificity resulted from comparison with histopathology (n=39) or follow-up (n=9). Phantom study revealed higher spatial resolution for axial than coronal views, whatever reconstruction interval was used. However, spatial frequency always remained high. Most pathological signs, such as bowel wall thickening (BWT), bowel wall enhancement (BWE) and intraperitoneal fluid (IPF), showed better interobserver agreement on axial than coronal views (BWT: 0.61 vs. 0.44; BWE: 0.56 vs. 0.5; IPF:0.53 vs. 0.43). The Wilcoxon signed-rank test revealed significantly higher sensitivity for axial than coronal views (P=0.0453); the time of reading was significantly shorter for the latter (P=0.0146). The diagnostic value of axial slices is superior to coronal reconstructions despite the reduced data volume and display of the physiological course of bowel loops on the coronal plane. (orig.)

  15. Anterior atlantodental and posterior atlantodental intervals on plain radiography, multidetector CT, and MRI

    International Nuclear Information System (INIS)

    Cha, Seung Woo; Ryu, Jeong Ah; Park, Dong Woo; Yoon, Ki Bo; Lee, Seung Hun; Joo, Kyung Bin

    2015-01-01

    To determine the normal values of the anterior atlantodental interval (AADI) and posterior atlantodental interval (PADI) on plain radiography, multidetector CT (MDCT) and MRI, as well as the dural sac width and spinal cord diameter at the atlantoaxial joint level on MRI. In total, 60 subjects underwent plain radiography, MRI and MDCT. We obtained values for AADI and PADI on plain radiography, MDCT, and MRI, and for dural sac width and spinal cord diameter on MRI. Two radiologists independently measured each value and a consensus was reached. The average AADI was 1.5 +/- 0.5 mm on plain radiography, 1.4 +/- 0.3 mm on MDCT, and 1.6 +/- 0.5 mm on MRI. The average PADI was 20.6 +/- 2.4 mm on plain radiography, 18.0 +/- 2.1 mm on MDCT, and 17.7 +/- 1.9 mm on MRI. The dural sac width was 13.7 +/- 1.8 mm, and the spinal cord diameter was 7.8 +/- 0.7 mm. Interobserver agreement was 0.701-0.927 and intraobserver agreement was 0.681-0.937. AADI values obtained on MDCT are significantly lower than those obtained on plain radiography or MRI. PADI values obtained on plain radiography are significantly higher than those obtained on MDCT or MRI. The dural sac width is most closely correlated with PADI values on MDCT. PADI seems to be easier to measure, more relevant, and clinically useful than AADI.

  16. Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement.

    Science.gov (United States)

    Freeman, Melanie; Webb, John G; Willson, Alexander B; Wheeler, Miriam; Blanke, Philipp; Moss, Robert R; Thompson, Christopher R; Munt, Brad; Norgaard, Bjarne L; Yang, Tae-Hyun; Min, James K; Poulsen, Steen; Hansson, Nicolaj C; Binder, Ronald K; Toggweiler, Stefan; Hague, Cameron; Wood, David A; Pibarot, Philippe; Leipsic, Jonathon

    2013-01-01

    Prosthesis-patient mismatch (PPM) is a predictor of mortality after aortic valve replacement (AVR). We examined whether accurate 3-dimensional annular sizing with multidetector CT (MDCT) is predictive of PPM after transcatheter AVR (TAVR). One hundred twenty-eight patients underwent MDCT then TAVR. Moderate PPM was defined as an indexed effective orifice area ≤0.85 cm²/m² and severe ≤0.65 cm²/m². MDCT annular measurements (area, short and long axis) were compared with the size of the selected transcatheter heart valve (THV) to obtain (1) the difference between prosthesis size and CT-measured mean annular diameter and (2) the percentage of undersizing or oversizing (calculated as 100 × [MDCT annular area--THV nominal area]/THV nominal area). In addition, the MDCT annular area was indexed to body surface area. These measures were evaluated as potential PPM predictors. We found that 42.2% of patients had moderate PPM and 9.4% had severe PPM. Procedural characteristics and in-hospital outcomes were similar between patients with or without PPM. THV undersizing of the mean aortic annulus diameter was not predictive of PPM (odds ratio [OR], 0.84; 95% CI, 0.65-1.07; P = .16; area under the receiver-operating characteristic curve [AUC], 0.58). THV undersizing of annular area was not predictive of PPM (OR, 0.96; 95% CI, 0.80-1.16; P = .69; AUC, 0.52). Indexed MDCT annular area was, however, predictive of PPM (OR, 0.24; 95% CI, 0.10-0.59; P < .001; AUC, 0.66). PPM is frequent after TAVR. Appropriate annular oversizing does not reduce the rate or severity of PPM. Patient annulus size mismatch, identified by indexed MDCT annular area, is a significant predictor of PPM. Copyright © 2013 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  17. Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT

    International Nuclear Information System (INIS)

    Flohr, T. G.; Stierstorfer, K.; Suess, C.; Schmidt, B.; Primak, A. N.; McCollough, C. H.

    2007-01-01

    We present and evaluate a special ultrahigh resolution mode providing considerably enhanced spatial resolution both in the scan plane and in the z-axis direction for a routine medical multi-detector row computed tomography (CT) system. Data acquisition is performed by using a flying focal spot both in the scan plane and in the z-axis direction in combination with tantalum grids that are inserted in front of the multi-row detector to reduce the aperture of the detector elements both in-plane and in the z-axis direction. The dose utilization of the system for standard applications is not affected, since the grids are moved into place only when needed and are removed for standard scanning. By means of this technique, image slices with a nominal section width of 0.4 mm (measured full width at half maximum=0.45 mm) can be reconstructed in spiral mode on a CT system with a detector configuration of 32x0.6 mm. The measured 2% value of the in-plane modulation transfer function (MTF) is 20.4 lp/cm, the measured 2% value of the longitudinal (z axis) MTF is 21.5 lp/cm. In a resolution phantom with metal line pair test patterns, spatial resolution of 20 lp/cm can be demonstrated both in the scan plane and along the z axis. This corresponds to an object size of 0.25 mm that can be resolved. The new mode is intended for ultrahigh resolution bone imaging, in particular for wrists, joints, and inner ear studies, where a higher level of image noise due to the reduced aperture is an acceptable trade-off for the clinical benefit brought about by the improved spatial resolution

  18. Usefulness of preoperative chest multidetector CT for evaluation of breast cancer: comparison with breast MRI

    International Nuclear Information System (INIS)

    Chang, Yun Woo; Kim, Dong Hun; Lee, Min Hyuk

    2005-01-01

    To evaluate the efficacy of chest multidetector-row helical computed tomography (MDCT) in detecting breast cancer in preoperative metastasis work-ups and to assess the accuracy of MDCT compared with magnetic resonance imaging (MRI). MDCT were performed on 69 consecutive patients with 94 lesions of histologically proven breast cancer. Retrospectively, two radiologists performed a blind review of the MDCT images for margin, shape, mass enhancement pattern and the enhancing distribution of non-mass lesions with consensus. CT attenuation values were measured in the average HU on pre-enhancing and enhanced CT in gland, fat, muscle, and in masses with the largest region of interest (ROI). MDCT finding were analyzed and compared with breast MRI. Of the 91 breast lesions detected on MDCT, 64 were mass lesions and 24 were non-mass lesions on enhancement, 86 lesions were malignant and 5 were benign. Three pathologically proven malignant masses were not detected on MDCT. Positive predictive value, false positive rate and false negative rate were 94.5%, 5.3%, 3.2% respectively. The highly predictive features for malignancy were a spiculated or irregular margin, an irregular of round shape, and a heterogeneously or rim enhanced mass. Another highly predictive feature for malignancy was linear or segmentally distributed enhancing non-mass lesions. The CT values of masses in pre-enhanced scans were 38.6 ± 7.9 HU; these values increased to 110.9 ± 26.6 HU after contrast injection (90 sec). The attenuation values from enhancing CT of malignant lesions were significantly higher than those of non-enhancing lesions. The depiction of enhancing masses on MDCT compared with MR imaging were 88.6%. The extension of malignancy were equally well correlated MDCT with MR imaging. The diagnostic value of chest MDCT for preoperative staging is comparable with MR imaging for the detection and extension of lesions. Therefore, chest MDCT of breast cancer can add to the information obtained from

  19. Radiation dose reduction on multidetector abdominal CT using adaptive statistical iterative reconstruction technique in children

    International Nuclear Information System (INIS)

    Zhang Qifeng; Peng Yun; Duan Xiaomin; Sun Jihang; Yu Tong; Han Zhonglong

    2013-01-01

    Objective: To investigate the feasibility to reduce radiation doses on pediatric multidetector abdominal CT using the adaptive statistical iterative reconstruction technique (ASIR) associated with automated tube current modulation technique (ATCM). Methods: Thirty patients underwent abdominal CT with ATCM and the follow-up scan with ATCM cooperated with 40% ASIR. ATCM was used with age dependent noise index (NI) settings: NI = 9 for 0-5 year old and NI = 11 for > 5 years old for simple ATCM group, NI = 11 for 0-5 year old and NI = 15 for > 5 years old for ATCM cooperated with 40% ASIR group (AISR group). Two radiologists independently evaluated images for diagnostic quality and image noise with subjectively image quality score and image noise score using a 5-point scale. Interobserver agreement was assessed by Kappa test. The volume CT dose indexes (CTDIvol) for the two groups were recorded. Statistical significance for the CTDIvol value was analyzed by pair-sample t test. Results: The average CTDIvol for the ASIR group was (1.38 ± 0.64) mGy, about 60% lower than (3.56 ± 1.23) mGy for the simple ATCM group, and the CTDIvol of two groups had statistically significant differences. (t = 33.483, P < 0.05). The subjective image quality scores for the simple ATCM group were 4.43 ± 0.57 and 4.37 ±0.61, Kappa = 0.878, P < 0.01 (ASIR group: 4.70 ± 0.47 and 4.60 ± 0.50, Kappa = 0.783, P < 0.01), by two observers. The image noise score for the simple ATCM group were 4.03 ±0.56 and 3.83 ±0.53, Kappa = 0.572, P < 0.01 (ASIR group: 4.20 ± 0.48 and 4.10 ± 0.48, Kappa = 0.748, P < 0.01), by two observers. All images had acceptable diagnostic image quality. Conclusion: Lower radiation dose can be achieved by elevating NI with ASIR in pediatric CT abdominal studies, while maintaining diagnostically acceptable images. (authors)

  20. Detecting Intracranial Hemorrhage Using Automatic Tube Current Modulation With Advanced Modeled Iterative Reconstruction in Unenhanced Head Single- and Dual-Energy Dual-Source CT.

    Science.gov (United States)

    Scholtz, Jan-Erik; Wichmann, Julian L; Bennett, Dennis W; Leithner, Doris; Bauer, Ralf W; Vogl, Thomas J; Bodelle, Boris

    2017-05-01

    The purpose of our study was to determine diagnostic accuracy, image quality, and radiation dose of low-dose single- and dual-energy unenhanced third-generation dual-source head CT for detection of intracranial hemorrhage (ICH). A total of 123 patients with suspected ICH were examined using a dual-source 192-MDCT scanner. Standard-dose 120-kVp single-energy CT (SECT; n = 36) and 80-kVp and 150-kVp dual-energy CT (DECT; n = 30) images were compared with low-dose SECT (n = 32) and DECT (n = 25) images obtained using automated tube current modulation (ATCM). Advanced modeled iterative reconstruction (ADMIRE) was used for all protocols. Detection of ICH was performed by three readers who were blinded to the image acquisition parameters of each image series. Image quality was assessed both quantitatively and qualitatively. Interobserver agreement was calculated using the Fleiss kappa. Radiation dose was measured as dose-length product (DLP). Detection of ICH was excellent (sensitivity, 94.9-100%; specificity, 94.7-100%) in all protocols (p = 1.00) with perfect interobserver agreement (0.83-0.96). Qualitative ratings showed significantly better ratings for both standard-dose protocols regarding gray matter-to-white matter contrast (p ≤ 0.014), whereas highest gray matter-to-white matter contrast-to-noise ratio was observed with low-dose DECT images (p ≥ 0.057). The lowest posterior fossa artifact index was measured for standard-dose DECT, which showed significantly lower values compared with low-dose protocols (p ≤ 0.034). Delineation of ventricular margins and sharpness of subarachnoidal spaces were rated excellent in all protocols (p ≥ 0.096). Low-dose techniques lowered radiation dose by 26% for SECT images (DLP, 575.0 ± 72.3 mGy · cm vs 771.5 ± 146.8 mGy · cm; p dual-source CT while allowing significant radiation dose reduction.

  1. Statistical iterative reconstruction for streak artefact reduction when using multidetector CT to image the dento-alveolar structures.

    Science.gov (United States)

    Dong, J; Hayakawa, Y; Kober, C

    2014-01-01

    When metallic prosthetic appliances and dental fillings exist in the oral cavity, the appearance of metal-induced streak artefacts is not avoidable in CT images. The aim of this study was to develop a method for artefact reduction using the statistical reconstruction on multidetector row CT images. Adjacent CT images often depict similar anatomical structures. Therefore, reconstructed images with weak artefacts were attempted using projection data of an artefact-free image in a neighbouring thin slice. Images with moderate and strong artefacts were continuously processed in sequence by successive iterative restoration where the projection data was generated from the adjacent reconstructed slice. First, the basic maximum likelihood-expectation maximization algorithm was applied. Next, the ordered subset-expectation maximization algorithm was examined. Alternatively, a small region of interest setting was designated. Finally, the general purpose graphic processing unit machine was applied in both situations. The algorithms reduced the metal-induced streak artefacts on multidetector row CT images when the sequential processing method was applied. The ordered subset-expectation maximization and small region of interest reduced the processing duration without apparent detriments. A general-purpose graphic processing unit realized the high performance. A statistical reconstruction method was applied for the streak artefact reduction. The alternative algorithms applied were effective. Both software and hardware tools, such as ordered subset-expectation maximization, small region of interest and general-purpose graphic processing unit achieved fast artefact correction.

  2. Usefulness of multidetector-row computed tomography (MD-CT) for diagnosis and evaluation of cardiovascular anomalies in infants

    International Nuclear Information System (INIS)

    Kani, Hiroyuki; Narabayashi, Isamu; Tanikake, Masato; Matsuki, Mitsuru; Uesugi, Yasuo

    2005-01-01

    We examined the effectiveness of multidetector-row CT (MD-CT) in the diagnosis and evaluation of cardiovascular anomalies in infants. MD-CT was performed 34 times on 21 patients with cardiovascular anomalies. We performed three evaluations: 1) The assessment of the specificity of MD-CT in detecting the morphological features of cardiovascular anomalies. 2) The diameters of aortae with coronary artery (CoA), and the diameters of pulmonary artery, measured by using MD-CT were compared with those by angiography. 3) The amount of exposure to radiation was measured. 1) MD-CT can detect CoA, pulmonary arteriovenous anomalies among extracardiac anomalies in all the patients. The diagnostic accuracy for intracardiac anomalies was poor as only six of the 15 anomalies could be accurately diagnosed. 2) The diameters of aortae and pulmonary artery obtained using MD-CT showed a good correlation with those obtained using arteriography (r=0.97, 0.95). 3) The average dose-length product was 269.2 mGy·cm. And the average effective dose was 5.1 mSv. MD-CT is not suitable for the evaluation of intracardiac anomalies, but is extremely effective in the evaluation of extracardiac major vascular anomalies. On the basis of the amount of information and noninvasive nature, MD-CT should be used first before angiography. (author)

  3. 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents

    International Nuclear Information System (INIS)

    Maintz, David; Seifarth, Harald; Rink, Michael; Oezguen, Murat; Heindel, Walter; Fischbach, Roman; Raupach, Rainer; Flohr, Thomas; Sommer, Torsten

    2006-01-01

    The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate visualization characteristics of of the stent, the lumen diameter, intraluminal density and noise were measured. The high-resolution kernel offered significantly better average lumen visualization (57% ±10%) and more realistic lumen attenuation (222 HU ±66 HU) at the expense of increased noise (15.3 HU ±3.7 HU) compared with the soft and medium-soft CT angiography (CTA) protocol (p<0.001 for all). Stents with a lumen visibility of more than 66% were: Arthos pico, Driver, Flex, Nexus2, S7, Tenax complete, Vision (all 67%), Symbiot, Teneo (70%), and Radius (73%). Only ten stents showed a lumen visibility of less than 50%. Stent lumen visibility largely varies depending on the stent type. Even with the improved spatial resolution of 64-slice CT, a stent-optimized kernel remains beneficial for stent visualization when compared with the standard medium-soft CTA protocol. Using 64-slice CT and high-resolution kernel, the majority of stent products show a lumen visibility of more than 50% of the stent

  4. Multidetector spiral CT renal angiography in the diagnosis of renal artery fibromuscular dysplasia

    International Nuclear Information System (INIS)

    Sabharwal, Rohan; Vladica, Philip; Coleman, Patrick

    2007-01-01

    Objective: The aim of this study was to evaluate the role and detection rate of multidetector spiral CT renal angiography (CTA) as compared with conventional angiography (CA), the commonly accepted gold standard, in the diagnosis of renal artery fibromuscular dysplasia (FMD). In addition, the role of CTA reconstructions (multiplanar reformatted images (MPR), maximum intensity projections (MIP) and shaded-surface display (SSD)) in the detection of FMD was also evaluated. Materials and methods: CTA results were retrospectively reviewed in 21 hypertensive patients with CA-proven FMD. Clinical indications for referral included resistant hypertension (requiring greater than three antihypertensive medications), labile hypertension, hypertension in combination with renal impairment and the presence of abdominal bruits in the context of systemic hypertension. In some cases, these clinical indications were supplemented by positive results in other tests, including plasma renin assay, captopril scintigraphy and/or Doppler ultrasound. The findings of CA in these 21 patients were compared to CTA. Results: Mean patient age was 62.33 + 14.32 years (range 24-85 years). CTA identified all 42 main renal arteries (100%) and all 10 accessory renal arteries (100%) visualized on CA. In the diagnosis of FMD, CTA detected all 40 (100%) lesions detected by CA. No single CTA reconstruction technique was able to detect all lesions noted on corresponding CA, however, upon review of all CTA reconstructions (MPR, MIP and SSD) in each case, every lesion was correctly identified by CTA. Conclusion: Our experience suggests that CTA is a non-invasive, reliable and accurate method for the diagnosis of renal artery fibromuscular dysplasia. Moreover, in our experience CTA has many advantages as a diagnostic screening tool over CA, including accessibility, speed, lower complication profile, versatility and cost-effectiveness. CTA shows great potential as a guiding tool for directing subsequent

  5. A method of estimating conceptus doses resulting from multidetector CT examinations during all stages of gestation

    International Nuclear Information System (INIS)

    Damilakis, John; Tzedakis, Antonis; Perisinakis, Kostas; Papadakis, Antonios E.

    2010-01-01

    Purpose: Current methods for the estimation of conceptus dose from multidetector CT (MDCT) examinations performed on the mother provide dose data for typical protocols with a fixed scan length. However, modified low-dose imaging protocols are frequently used during pregnancy. The purpose of the current study was to develop a method for the estimation of conceptus dose from any MDCT examination of the trunk performed during all stages of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study to model the Siemens Sensation 16 and Sensation 64 MDCT scanners. Four mathematical phantoms were used, simulating women at 0, 3, 6, and 9 months of gestation. The contribution to the conceptus dose from single simulated scans was obtained at various positions across the phantoms. To investigate the effect of maternal body size and conceptus depth on conceptus dose, phantoms of different sizes were produced by adding layers of adipose tissue around the trunk of the mathematical phantoms. To verify MCNP results, conceptus dose measurements were carried out by means of three physical anthropomorphic phantoms, simulating pregnancy at 0, 3, and 6 months of gestation and thermoluminescence dosimetry (TLD) crystals. Results: The results consist of Monte Carlo-generated normalized conceptus dose coefficients for single scans across the four mathematical phantoms. These coefficients were defined as the conceptus dose contribution from a single scan divided by the CTDI free-in-air measured with identical scanning parameters. Data have been produced to take into account the effect of maternal body size and conceptus position variations on conceptus dose. Conceptus doses measured with TLD crystals showed a difference of up to 19% compared to those estimated by mathematical simulations. Conclusions: Estimation of conceptus doses from MDCT examinations of the trunk performed on pregnant patients during all stages of gestation can be made

  6. Multidetector CT features of pulmonary focal ground-glass opacity: differences between benign and malignant

    Science.gov (United States)

    Fan, L; Liu, S-Y; Li, Q-C; Yu, H; Xiao, X-S

    2012-01-01

    Objective To evaluate different features between benign and malignant pulmonary focal ground-glass opacity (fGGO) on multidetector CT (MDCT). Methods 82 pathologically or clinically confirmed fGGOs were retrospectively analysed with regard to demographic data, lesion size and location, attenuation value and MDCT features including shape, margin, interface, internal characteristics and adjacent structure. Differences between benign and malignant fGGOs were analysed using a χ2 test, Fisher's exact test or Mann–Whitney U-test. Morphological characteristics were analysed by binary logistic regression analysis to estimate the likelihood of malignancy. Results There were 21 benign and 61 malignant lesions. No statistical differences were found between benign and malignant fGGOs in terms of demographic data, size, location and attenuation value. The frequency of lobulation (p=0.000), spiculation (p=0.008), spine-like process (p=0.004), well-defined but coarse interface (p=0.000), bronchus cut-off (p=0.003), other air-containing space (p=0.000), pleural indentation (p=0.000) and vascular convergence (p=0.006) was significantly higher in malignant fGGOs than that in benign fGGOs. Binary logistic regression analysis showed that lobulation, interface and pleural indentation were important indicators for malignant diagnosis of fGGO, with the corresponding odds ratios of 8.122, 3.139 and 9.076, respectively. In addition, a well-defined but coarse interface was the most important indicator of malignancy among all interface types. With all three important indicators considered, the diagnostic sensitivity, specificity and accuracy were 93.4%, 66.7% and 86.6%, respectively. Conclusion An fGGO with lobulation, a well-defined but coarse interface and pleural indentation gives a greater than average likelihood of being malignant. PMID:22128130

  7. Role of multidetector CT angiography in the evaluation of suspected mesenteric ischemia

    International Nuclear Information System (INIS)

    Barmase, Meghna; Kang, Mandeep; Wig, Jaidev; Kochhar, Rakesh; Gupta, Rajesh; Khandelwal, Niranjan

    2011-01-01

    Objective: To assess the role of multidetector CT angiography (MDCTA) in the diagnosis of acute mesenteric ischemia (AMI) and to compare the diagnostic utility of axial images with reconstructed images. Materials and methods: In this Institute Review Board approved prospective study, MDCTA was performed on 31 patients who presented with the clinical suspicion of AMI (25M; 6F, age range: 16–73 years). Axial and reconstructed images of each patient were evaluated independently by two radiologists for evidence of bowel wall thickening, abnormal mucosal enhancement, bowel dilatation or obstruction, mesenteric stranding, ascites, solid organ infarcts, pneumatosis intestinalis or porto-mesenteric gas, and mesenteric arterial or venous occlusion. MDCT findings were correlated with the surgical findings and clinical outcome. Patients were later divided into two groups: a study group of patients with proven AMI and a control group of patients with an alternate diagnosis, for the purpose of statistical analysis. Results: AMI was correctly diagnosed in all 16 patients on MDCTA (100% sensitivity and specificity) of whom nine patients underwent surgical exploration. Three patients expired before surgery and the remaining 5 patients were proven based on positive clinical and laboratory findings. Mesenteric arterial occlusion was seen in 7 patients while 5 patients had portomesenteric venous thrombosis. Reconstructed images using minimum intensity projection, volume rendering and multiplanar volume reconstruction were found to perform better for the detection of vascular abnormalities and improved the diagnostic confidence of both radiologists in the evaluation of bowel and mesenteric abnormalities. Conclusion: MDCTA is an effective non-invasive modality for the diagnosis of mesenteric ischemia.

  8. The quality of reconstructed 3D images in multidetector-row helical CT: experimental study involving scan parameters

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Lee, Ho Kyu; Choi, Choong Gon; Suh, Dae Chul; Lim, Tae Hwan; Kang, Weechang

    2002-01-01

    To determine which multidetector-row helical CT scanning technique provides the best-quality reconstructed 3D images, and to assess differences in image quality according to the levels of the scanning parameters used. Four objects with different surfaces and contours were scanned using multidetector-row helical CT at three detector-row collimations (1.25, 2.50, 5.00 mm), two pitches (3.0, 6.0), and three different degrees of overlap between the reconstructed slices (0%, 25%, 50%). Reconstructed 3D images of the resulting 72 sets of data were produced using volumetric rendering. The 72 images were graded on a scale from 1 (worst) to 5 (best) for each of four rating criteria, giving a mean score for each criterion and an overall mean score. Statistical analysis was used to assess differences in image quality according to scanning parameter levels. The mean score for each rating criterion, and the overall mean score, varied significantly according to the scanning parameter levels used. With regard to detector-row collimation and pitch, all levels of scanning parameters gave rise to significant differences, while in the degree of overlap of reconstructed slices, there were significant differences between overlap of 0% and of 50% in all levels of scanning parameters, and between overlap of 25% and of 50% in overall accuracy and overall mean score. Among the 18 scanning sequences, the highest score (4.94) was achieved with 1.25 mm detector-row collimation, 3.0 pitch, and 50% overlap between reconstructed slices. Comparison of the quality of reconstructed 3D images obtained using multidetector-row helical CT and various scanning techniques indicated that the 1.25 mm, 3.0, 50% scanning sequence was best. Quality improved as detector-row collimation decreased; as pitch was reduced from 6.0 to 3.0; and as overlap between reconstructed slices increased

  9. Prenatal diagnosis of chondrodysplasia punctata tibia-metacarpal type using multidetector CT and three-dimensional reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Miyazaki, Osamu [National Centre for Child Health and Development, Department of Radiology, Tokyo (Japan); Nishimura, Gen [Tokyo Metropolitan Kiyose Children' s Hospital, Department of Radiology, Tokyo (Japan); Sago, Haruhiko; Watanabe, Noriyoshi; Ebina, Shunsuke [National Centre for Child Health and Development, Department of Perinatal Medicine and Maternal Care, Tokyo (Japan)

    2007-11-15

    We report a case of chondrodysplasia punctata tibia-metacarpal type (CDP-TM) that was diagnosed prenatally using multidetector CT (MDCT) with three-dimensional (3-D) CT reconstructions. Prenatal US had shown severe thoracic hypoplasia and rhizomelic shortening of the limbs, raising the suspicion of thanatophoric dysplasia. However, MDCT showed punctate calcifications in the epiphyseal cartilage of the humeri and femora, carpal bones, and paravertebral region. On 3-D CT, the tibiae were much shorter than the fibulae, the humeri were very short and bowed, and severe platyspondyly was evident. These findings led to the diagnosis of CDP-TM. The diagnosis was confirmed on postnatal radiographs. Prenatal MDCT with 3-D images may make a useful contribution to prenatal diagnosis in selected fetuses with severe skeletal dysplasia. (orig.)

  10. Calcified pulmonary thromboembolism in a child with sickle cell disease: value of multidetector CT in patients with acute chest syndrome

    International Nuclear Information System (INIS)

    Staser, Jonathan A.; Alam, Tariq; Applegate, Kimberly

    2006-01-01

    The incidence of pulmonary embolism in children is not clearly known, but is believed to be low. Risk factors for pulmonary thromboembolism include central venous catheter, malignancy, surgery, infection, trauma, and congenital hypercoagulable disorders. Children with sickle cell disease are prothrombotic and are at an increased risk of thromboembolism. The incidence of this event is unknown because these children are often not thoroughly imaged. We report here a case of a calcified pulmonary thromboembolism in a child with sickle cell disease and emphasize the use of multidetector CT in detection of pulmonary thromboembolism in children with sickle cell disease. (orig.)

  11. Diagnostic value of multidetector row CT in rectal cancer staging: comparison of multiplanar and axial images with histopathology

    International Nuclear Information System (INIS)

    Sinha, R.; Verma, R.; Rajesh, A.; Richards, C.J.

    2006-01-01

    Aim: Although magnetic resonance (MR) imaging is widely used for rectal cancer staging, many centres in the UK perform computed tomography (CT) for staging rectal cancer at present. Furthermore in a small proportion of cases contraindications to MR imaging may lead to staging using CT. The purpose of this study was to evaluate the accuracy of current generation multidetector row CT (MDCT) in local staging of rectal cancer. In particular the accuracy of multiplanar (MPR) versus axial images in the staging of rectal cancer was assessed. Material and methods: Sixty-nine consecutive patients were identified who had undergone staging of rectal cancer on CT. The imaging data were reviewed as axial images and then as MPR images (coronal and sagittal) perpendicular and parallel to the tumour axis. CT staging on axial and MPR images was then compared to histopathological staging. Results: MPR images detected more T4 and T3 stage tumours than axial images alone. The overall accuracy of T-staging on MPR images was 87.1% versus 73.0% for axial images alone. The overall accuracy of N staging on MPR versus axial images was 84.8% versus 70.7%. There was a statistically significant difference in the staging of T3 tumours between MPR and axial images (p < 0.001). Conclusion: Multidetector row CT has high accuracy for local staging of rectal cancer. Addition of MPR images to standard axial images provides higher accuracy rates for T and N staging of rectal cancer than axial images alone

  12. Multi-detector row CT in the assessment of axillary lymph node metastasis in breast cancer

    International Nuclear Information System (INIS)

    Murakami, Shogo

    2003-01-01

    The purpose of this study is to evaluate the diagnostic capability instead of clinical efficacy of multi-detector row CT (MDCT) in the assessment of axillary lymph node metastasis in breast cancer. MDCT was performed in 63 patients with breast cancer, and multiplanar reformation (MPR) and volume rendering (VR) images were reconstructed for the evaluation of bilateral axillary lymph nodes. Two hundred sixty eight lymph nodes were depicted with MDCT, and correlation with pathological findings was performed. The short axis length of lymph node was measured on MPR image, and the shape of the nodes was analyzed with the pathological results statistically. The diagnostic criteria on size and shape of lymph node metastasis were discussed Dynamic study with contrast media was also performed, and the CT value ratios (CTVR) of the lymph nodes and breast tumors were calculated. No relevance of axillary lymph node metastasis was noted to the pathological types of breast cancer. The average short axis length of the ipsilateral axillary nodes was 8.9 mm±3.8 (SD) while that of the contralateral nodes was 4.9 mm±1.1 (SD) showing significant difference. More than 6.5 mm in short length of the lymph node was thought to be an effective criterion for positive metastasis, and its sensitivity was 96%. Soybean-shape lymph node was statistically common in metastasis, while non-metastatic nodes were commonly demonstrated as letter ''c'' shape or ring-like shape. Statistical relevance was obtained between the CTVR of axillary lymph nodes and that of breast tumors, suggesting clinical usefulness of dynamic study using contrast media in the evaluation of lymph node metastasis. With MPR and VR images using MDCT, more accurate morphological evaluation of axillary lymph nodes was possible. When soybean-shape node with more than 6.5 mm in short axis is depicted in the axillar region on MDCT metastasis should be the consideration. Comparison with the contralateral side as a control in coronal

  13. Study of Image Quality From CT Scanner Multi-Detector by using Americans College of Radiology (ACR) Phantom

    Science.gov (United States)

    Mulyadin; Dewang, Syamsir; Abdullah, Bualkar; Tahir, Dahlang

    2018-03-01

    In this study, the image quality of CT scan using phantom American College of Radiology (ACR) was determined. Scanning multidetector CT is used to know the image quality parameters by using a solid phantom containing four modules and primarily from materials that are equivalent to water. Each module is 4 cm in diameter and 20 cm in diameter. There is white alignment marks painted white to reflect the alignment laser and there are also “HEAD”, “FOOT”, and “TOP” marks on the phantom to help align. This test obtains CT images of each module according to the routine inspection protocol of the head. Acceptance of image quality obtained for determination: CT Number Accuracy (CTN), CT Number Uniformity and Noise, Linearity CT Number, Slice Technique, Low Contrast Resolution and High Contrast Resolution represent image quality parameters. In testing CT Number Accuracy (CTN), CT Uniform number and Noise are in the range of tolerable values allowed. In the test, Linearity CT Number obtained correlation value above 0.99 is the relationship between electron density and CT Number. In a low contrast resolution test, the smallest contrast groups are visible. In contrast, the high resolution is seen up to 7 lp/cm. The quality of GE CT Scan is very high, as all the image quality tests obtained are within the tolerance brackets of values permitted by the Nuclear Power Control Agency (BAPETEN). Image quality test is a way to get very important information about the accuracy of snoring result by using phantom ACR.

  14. Regenerative nodules in patients with chronic Budd-Chiari syndrome: A longitudinal study using multiphase contrast-enhanced multidetector CT

    International Nuclear Information System (INIS)

    Flor, Nicola; Zuin, Massimo; Brovelli, Francesca; Maggioni, Marco; Tentori, Augusta; Sardanelli, Francesco; Cornalba, Gian Paolo

    2010-01-01

    Objective: Our aim was to evaluate the serial evolution of regenerative nodules in patients with Budd-Chiari syndrome (BCS) treated with portal-systemic shunts, using multiphasic multidetector computed tomography (MDCT). Materials and methods: Five patients each underwent three MDCT exams over an extended period ranging from 36 to 42 months. Two radiologists in consensus retrospectively reviewed each exam for each patient. Individual nodules were grouped according to size (size I: nodules with diameter ≤15 mm; size II: >15 mm but <30 mm; size III: ≥30 mm), pattern of enhancement (A: homogeneously hypervascular or B: with central scar), and segmental location. Four nodules classified as size II, which increased in size over time, were needle-biopsied. Results: We detected 61 nodules at the first exam, 66 nodules at the second exam (7 nodules disappeared and 12 new nodules), and 85 nodules at the third exam (8 disappeared and 27 new) for a total of 212 findings. Nodules were mostly found in the right hepatic lobe. Fourteen of the 15 nodules that disappeared over time were size I and enhancement pattern A. At unenhanced MDCT, 204 (96%) of the 212 findings were isodense. Overall, 100 nodules, including the 61 initially detected, were considered newly diagnosed; of these 84 (84%) were size I and pattern A. Of 57 nodules considered size I and pattern A at the first or second exam, 24 (42%) changed to pattern B at the third exam and either size II (n = 18) or III (n = 6). The four biopsied nodules were each confirmed as benign regenerative nodule. No patient developed HCC at 5-year follow-up period. Conclusion: Hepatic nodules in BCS patients not only increase in number over time but may also increase in size and develop a central scar.

  15. Peliosis Hepatis with Hemorrhagic Necrosis and Rupture: a Case Report with Emphasis on the Multi-Detector CT Findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun-A; Yoon, Kwon-Ha; Jeon, Se-Jung; Cai, Quan-Yu; Lee, Young-Whan [Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2007-02-15

    We demonstrate the imaging findings, with emphasis on the triphasic, contrast-enhanced multidetector CT findings, as well as reporting the clinical outcome in a case of peliosis hepatis with fatal hemorrhage. eliosis hepatis is an uncommon condition characterized by blood-filled cystic cavities in the liver. The clinical presentation is quite variable from an asymptomatic presentation to hepatic failure, portal hypertension or fatal intraabdominal hemorrhage. The exact incidence of intrahepatic or intraperitoneal hemorrhage by liver rupture has not been determined in the literature and these complications have been demonstrated only in the form of about 20 case reports. On angiography, peliosis hepatis can be suspected by multiple small contrast accumulations that become distinct during the parenchymal phase and are persistent during the venous phase. Examinations using multidetector CT (MDCT) scanners, which provide thin-section, contrast-enhanced dynamic images, are increasing nowadays. Thus, this entity has a better chance to be incidentally encountered and to be a diagnostic challenge to the radiologists. In this report, we present a case of peliosis hepatis with hemorrhagic necrosis that was complicated by massive intrahepatic bleeding and rupture. We demonstrate the imaging findings with emphasis on the contrast-enhanced dynamic MDCT features as well as the clinical outcome after treatment.

  16. Peliosis Hepatis with Hemorrhagic Necrosis and Rupture: a Case Report with Emphasis on the Multi-Detector CT Findings

    International Nuclear Information System (INIS)

    Kim, Eun-A; Yoon, Kwon-Ha; Jeon, Se-Jung; Cai, Quan-Yu; Lee, Young-Whan

    2007-01-01

    We demonstrate the imaging findings, with emphasis on the triphasic, contrast-enhanced multidetector CT findings, as well as reporting the clinical outcome in a case of peliosis hepatis with fatal hemorrhage. eliosis hepatis is an uncommon condition characterized by blood-filled cystic cavities in the liver. The clinical presentation is quite variable from an asymptomatic presentation to hepatic failure, portal hypertension or fatal intraabdominal hemorrhage. The exact incidence of intrahepatic or intraperitoneal hemorrhage by liver rupture has not been determined in the literature and these complications have been demonstrated only in the form of about 20 case reports. On angiography, peliosis hepatis can be suspected by multiple small contrast accumulations that become distinct during the parenchymal phase and are persistent during the venous phase. Examinations using multidetector CT (MDCT) scanners, which provide thin-section, contrast-enhanced dynamic images, are increasing nowadays. Thus, this entity has a better chance to be incidentally encountered and to be a diagnostic challenge to the radiologists. In this report, we present a case of peliosis hepatis with hemorrhagic necrosis that was complicated by massive intrahepatic bleeding and rupture. We demonstrate the imaging findings with emphasis on the contrast-enhanced dynamic MDCT features as well as the clinical outcome after treatment

  17. 16-slice multi-detector row CT coronary angiography: image quality and optimization of the image reconstruction window

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Shim, Sung Shine; Lim, Soo Mee; Hwang, Ji Young; Kim, Yoon Kyung

    2005-01-01

    The purpose of this experiment is to investigate the image quality of CT coronary angiography using a 16-slice multi-detector row CT and to determine the optimal image reconstruction window. CT coronary angiography was obtained in 36 nonsymptomatic volunteers using a 16-slice multi-detector row CT (SOMATOM Sensation, Siemens Medical System). The mean heart rates were 70 beats per minute (bpm) or less in 18 persons and more than 70 bpm in 18 persons. Eleven data sets were obtained for each patient (reconstructed at 30%-80% of the cardiac cycle with an increment of 5%). Image quality of the eight coronary segments [left main coronary artery (LM), proximal and middle segments of left anterior descending artery (p-LAD, m-LAN) and left circumflex coronary artery (p-LCx, m-LCx) and proximal, middle and distal segments of right coronary artery (p-RCA, m-RCA, d-RCA)] was assessed. The optimal reconstruction windows in the cardiac cycle for the best image quality were 60-70% for the segments of the LM, LAD, and LC arteries in two groups (bpm 70) and 55-65% (bpm 70) for the segments of the RCA. On the best dataset for each coronary segment, the following diagnostic image quality was achieved in the two groups: LM: 100%, 83%; p-LAD: 100%, 88% m-LAD: 100%, 72%; p-LCx: 100%, 72%; m-LCx: 100%, 72%; p-RCA: 94%, 72%; m-RCA: 61%, 50%; d-RCA: 100%, 80%. The 16 slice multi-detector row CT scan provided visualization of the coronary arteries with high resolution. Especially in the group with a mean heart rate of 70 bpm or less, all the coronary segments except the RCA showed diagnostic image quality. Optimal image quality was achieved with a 60-70% trigger delay for all coronary arterial segments, but the best images of RCA were achieved in the earlier cardiac phase in the patients with a mean heart rate of more than 70 bpm

  18. Diagnosis of multidetector spiral CT and its reconstruction techniques in trachea and principal bronchus tumors

    Energy Technology Data Exchange (ETDEWEB)

    Mingyue, Luo; Hong, Shan; Zaibo, Jiang; Lufang, Li; Jiansheng, Zhang [Zhongshan Univ., Guangzhou (China). The Third Univ. Hospital, Dept. of Radiology; Lijia, Gu; Shaohong, Huang; Yi, Jin; Zhiqiang, Hou

    2003-12-01

    Objective: To investigate the clinical diagnostic value of multidetector spiral CT (MSCT) and its reconstruction techniques including multiplanar volume reformation (MPVR), volume rendering (VR), and virtual bronchoscopy (VB) in the trachea and principal bronchus tumors. Methods: Thin slice MSCT scanning was performed in 31 patients with suspected trachea or principal bronchus tumors, and image reconstruction data were formed after retro-reconstructing of initial scanning data. MPVR, VR, and VB images were obtained respectively by postprocessing of image reconstruction data with MPVR, VR, and VB image processing software in AW workstation. The findings of MSCT initial axial images, MPVR, VR, and VB images were compared with surgical and pathological results. Results: MSCT initial axial images combined with MPVR, VR, and VB images displayed the locations (tracheae, n=19; right principal bronchi, n=6; left principal bronchi, n=6), morphologies (endoluminal nodular tumors with narrow bases, n=2; endoluminal nodular tumors with wide bases, n=13; intraluminal and extraluminal massive tumors, n=16), internal features (1 had homogeneous density, 1 had low density, they both without obvious enhancement; 23 squamous cell carcinomas and 3 adenocarcinomas had fairly homogeneous density and rather obvious enhancement; 1 had homogeneous density, 1 had inhomogeneous density, 1 had punctate calcification, all with obvious enhancement), extramural invasion situations (broke through only serous membrane, n=1; no clear border with right atelectatic lung tissue, n=1; ranges of extramural invasion 4-56 mm, n=14), morphologies of luminal stenoses (eccentric, n=1; irregular, n=26; circular, n=3; conical interruption, n=1), extents (mild, n=5; moderate, n=7; severe, n=19); measured longitudinal invasion ranges (only 3 mm, n=1; invaded the whole right principal bronchus wall and carina, n=1; 5-68 mm, n=29), and distances between principal bronchus tumors and carina (invaded carina, n=1

  19. Multidetector CT findings of splenic artery aneurysm in children with chronic liver disease

    International Nuclear Information System (INIS)

    Ulu, Esra Meltem Kayahan; Kirbas, Ismail; Emiroglu, Feride Kural; Cakir, Banu; Harman, Ali; Coskun, Mehmet; Bakar, Coskun

    2008-01-01

    Splenic artery aneurysm (SAA) is a well-known complication of chronic liver disease and portal hypertension in adults. The incidence of SAA in children undergoing selective hepatic angiography prior to liver transplantation is reported as 4%, but there are few systematic studies. To investigate the SAAs detected by multidetector CT angiography (MDCTA) among children with chronic liver disease. A total of 124 children (71 girls, 53 boys; mean age 118 months; age range 5 days to 204 months) with chronic liver disease underwent MDCTA to display the vascular anatomy and any vascular complications during the pretransplantation period. Of these children, 23 also underwent coeliac angiography. The digital subtraction angiography (DSA) and MDCTA findings were compared. SAAs were detected in 13 children (10.4%); none was detectable by US. All patients had more than one aneurysm; ten patients had more than three. In all except one patient, the SAAs were located only in the intraparenchymal branches of the splenic artery; in one patient they were located in the intraparenchymal segment and in the distal third of the splenic artery. The mean size of the aneurysms was 6.5 mm (range 2.5-18 mm). All patients with aneurysms had splenomegaly and vascular collaterals. Nine of the children with SAAs had portal vein pathologies (two occlusions, two stenoses, five dilatations). A statistically significant difference existed with regard to the size of spleen (P < 0.05) and patient age (P < 0.05) between children with SAAs and children without SAAs. There was an increased risk of SAAs in patients with portal vein pathologies. In 19 patients without SAAs on MDCTA, no SAAs were seen on DSA. It is likely that the incidence of SAA in children with chronic liver disease will increase with improved survival of children with long-standing portal hypertension and chronic liver disease. MDCTA with multiplanar reconstruction is a noninvasive and effective means of imaging paediatric patients with

  20. Multidetector CT findings of splenic artery aneurysm in children with chronic liver disease

    Energy Technology Data Exchange (ETDEWEB)

    Ulu, Esra Meltem Kayahan; Kirbas, Ismail; Emiroglu, Feride Kural; Cakir, Banu; Harman, Ali; Coskun, Mehmet [Baskent University Faculty of Medicine, Department of Radiology, Ankara (Turkey); Bakar, Coskun [Baskent University Faculty of Medicine, Department of Public Health, Ankara (Turkey)

    2008-10-15

    Splenic artery aneurysm (SAA) is a well-known complication of chronic liver disease and portal hypertension in adults. The incidence of SAA in children undergoing selective hepatic angiography prior to liver transplantation is reported as 4%, but there are few systematic studies. To investigate the SAAs detected by multidetector CT angiography (MDCTA) among children with chronic liver disease. A total of 124 children (71 girls, 53 boys; mean age 118 months; age range 5 days to 204 months) with chronic liver disease underwent MDCTA to display the vascular anatomy and any vascular complications during the pretransplantation period. Of these children, 23 also underwent coeliac angiography. The digital subtraction angiography (DSA) and MDCTA findings were compared. SAAs were detected in 13 children (10.4%); none was detectable by US. All patients had more than one aneurysm; ten patients had more than three. In all except one patient, the SAAs were located only in the intraparenchymal branches of the splenic artery; in one patient they were located in the intraparenchymal segment and in the distal third of the splenic artery. The mean size of the aneurysms was 6.5 mm (range 2.5-18 mm). All patients with aneurysms had splenomegaly and vascular collaterals. Nine of the children with SAAs had portal vein pathologies (two occlusions, two stenoses, five dilatations). A statistically significant difference existed with regard to the size of spleen (P < 0.05) and patient age (P < 0.05) between children with SAAs and children without SAAs. There was an increased risk of SAAs in patients with portal vein pathologies. In 19 patients without SAAs on MDCTA, no SAAs were seen on DSA. It is likely that the incidence of SAA in children with chronic liver disease will increase with improved survival of children with long-standing portal hypertension and chronic liver disease. MDCTA with multiplanar reconstruction is a noninvasive and effective means of imaging paediatric patients with

  1. Clinical usefulness of multidetector-row CT to evaluate coronary artery calcium score in type 2 diabetes

    International Nuclear Information System (INIS)

    Nishioka, Makiko; Sakuma, Toru; Sano, Hironari; Utsunomiya, Kazunori; Agata, Toshihiko; Shimizu, Keisuke; Tajima, Naoko

    2004-01-01

    According to recent studies, multidetector-row CT (MDCT) with a retrospective electrocardiogram (ECG)-gating reconstruction algorithm shows a high correlation with coronary artery calcium score determined using electron-beam CT. Diabetes leads to many macrovascular complications, including coronary artery disease. The aim of this study was to evaluate risk factors for cardiac macroangiopathy in type 2 diabetes using MDCT. An observational cross-sectional study was performed in 90 patients with diabetes mellitus. Coronary calcium data was acquired by MDCT (SOMATOM Volume Zoom, Siemens AG, Medical Solutions, Germany). Physical examinations, laboratory data, glycemic control, and control of other risk factors were analyzed. The coronary artery calcium score increased with age. Multivariant analysis revealed that the coronary calcium score was closely correlated with electrocardiogram evaluation and control of hypertension. Coronary artery calcium score as determined by MDCT can be used as a screening radiological examination for cardiac macroangiopathy in diabetes patients with electrocardiogram abnormality and hypertension. (author)

  2. Angiographic frequency of blunt cerebrovascular injury in patients with carotid canal or vertebral foramen fractures on multidetector CT

    International Nuclear Information System (INIS)

    McKinney, Alexander; Ott, Frederick; Short, James; McKinney, Zeke; Truwit, Charles

    2007-01-01

    Purpose: Blunt carotid injuries (BCI's) and blunt vertebral artery injuries (BVI's), known jointly as BCVI's, are common in 'high risk' patients. The purpose is to evaluate the rate of occurrence of BCI/BVI in patients screened purely by the radiologic criteria of fracture through the carotid canal or vertebral transverse foramina, or significant cervical subluxation, noted by multidetector CT. Methods: Seventy-one patients with 108 catheterized vessels were included over a 13-month interval. The angiographic examinations were prompted by current hospital protocol, solely by the presence of fractures involving/adjacent to the carotid canal, cervical fractures involving/adjacent to the foramen transversarium, or cervical fractures with significant subluxation. The incidence of each grade of blunt injury was calculated after review of the CT scans and catheter angiograms by two neuroradiologists. Results: Two thousand and seventy-three total blunt trauma admissions occurred during the time period, with a BCVI rate of 0.92-1.0% (depending on the reviewer), similar to previous studies. Mean time to catheter angiography was 16.6 h. Of the 71 included patients, there were 11-12 BCI's and 10-12 BVI's, an overall rate of 27-30% of BCVI in the patients with foraminal fractures. Interobserver agreement in reviewing the catheter angiograms was excellent (Kappa 0.795). Of note, three internal carotid pseudoaneurysms resolved spontaneously after anticoagulation or aspirin. Conclusion: This study confirms that there is a high rate of BCVI in the presence of carotid canal or vertebral foramen fractures that are noted by multidetector CT. Utilization of purely radiologic criteria of foraminal involvement may be a significant screening tool in the decision of whether to evaluate these patients acutely by catheter or CT angiography, and for early detection of patients at risk for symptomatology, to initiate prompt, prophylactic treatment

  3. Angiographic frequency of blunt cerebrovascular injury in patients with carotid canal or vertebral foramen fractures on multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    McKinney, Alexander [Department of Radiology, Hennepin County and University of Minnesota-Fairview and Medical Centers, Minneapolis, MN (United States)]. E-mail: mckin022@umn.edu; Ott, Frederick [Department of Radiology, Hennepin County and University of Minnesota-Fairview and Medical Centers, Minneapolis, MN (United States); Short, James [Department of Radiology, Hennepin County and University of Minnesota-Fairview and Medical Centers, Minneapolis, MN (United States); McKinney, Zeke [Department of Radiology, Hennepin County and University of Minnesota-Fairview and Medical Centers, Minneapolis, MN (United States); Truwit, Charles [Department of Radiology, Hennepin County and University of Minnesota-Fairview and Medical Centers, Minneapolis, MN (United States)

    2007-06-15

    Purpose: Blunt carotid injuries (BCI's) and blunt vertebral artery injuries (BVI's), known jointly as BCVI's, are common in 'high risk' patients. The purpose is to evaluate the rate of occurrence of BCI/BVI in patients screened purely by the radiologic criteria of fracture through the carotid canal or vertebral transverse foramina, or significant cervical subluxation, noted by multidetector CT. Methods: Seventy-one patients with 108 catheterized vessels were included over a 13-month interval. The angiographic examinations were prompted by current hospital protocol, solely by the presence of fractures involving/adjacent to the carotid canal, cervical fractures involving/adjacent to the foramen transversarium, or cervical fractures with significant subluxation. The incidence of each grade of blunt injury was calculated after review of the CT scans and catheter angiograms by two neuroradiologists. Results: Two thousand and seventy-three total blunt trauma admissions occurred during the time period, with a BCVI rate of 0.92-1.0% (depending on the reviewer), similar to previous studies. Mean time to catheter angiography was 16.6 h. Of the 71 included patients, there were 11-12 BCI's and 10-12 BVI's, an overall rate of 27-30% of BCVI in the patients with foraminal fractures. Interobserver agreement in reviewing the catheter angiograms was excellent (Kappa 0.795). Of note, three internal carotid pseudoaneurysms resolved spontaneously after anticoagulation or aspirin. Conclusion: This study confirms that there is a high rate of BCVI in the presence of carotid canal or vertebral foramen fractures that are noted by multidetector CT. Utilization of purely radiologic criteria of foraminal involvement may be a significant screening tool in the decision of whether to evaluate these patients acutely by catheter or CT angiography, and for early detection of patients at risk for symptomatology, to initiate prompt, prophylactic treatment.

  4. Detection of pulmonary embolism with combined ventilation-perfusion SPECT and low-dose CT: head-to-head comparison with multidetector CT angiography

    DEFF Research Database (Denmark)

    Gutte, Henrik; Mortensen, Jann; Jensen, Claus Verner

    2009-01-01

    The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer testing, and imaging with either pulmonary ventilation-perfusion (V/Q) scintigraphy or pulmonary multidetector CT (MDCT) angiography. Both V/Q SPECT and MDCT angiography seem to have...... high diagnostic accuracy. However, only limited data directly comparing these 2 modalities are available. Hybrid gamma-camera/MDCT systems have been introduced and allow simultaneous 3-dimensional lung V/Q SPECT and MDCT angiography, suitable for diagnosing PE. The aim of our study was to compare...

  5. Imaging patterns of hepatic steatosis on multidetector CT: Pearls and pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Kani, K.K., E-mail: khalatbarik@yahoo.com [Department of Radiology, Body Imaging, University of Washington Medical Center, Seattle, WA (United States); Moshiri, M.; Cuevas, C.; Lee, J.H.; Mitsumori, L.M.; Kolokythas, O. [Department of Radiology, Body Imaging, University of Washington Medical Center, Seattle, WA (United States)

    2012-04-15

    Fatty liver disease is an important cause of chronic liver disease in Western countries. The purpose of this article is to describe and illustrate the diagnostic criteria and various morphological patterns of fatty liver disease on multidetector computed tomography (MDCT) with an emphasis on potential limitations and diagnostic pitfalls.

  6. Diagnostic Accuracy of the Volume Rendering Images of Multi-Detector CT for the Detection of Lumbar Transverse Process Fractures

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yun Hak; Chun, Tong Jin [Dept. of Radiology, Eulji University Hospital, Daejeon (Korea, Republic of)

    2012-01-15

    To compare the accuracy of three-dimensional computed tomographic (3D CT) volume rendering techniques with axial images of multi-detector row computed tomography to identify lumbar transverse process (LTP) fractures in trauma patients. We retrospectively evaluated 42 patients with back pain as a result of blunt trauma between January and June of 2010. Two radiologists examined the 3D CT volume rendering images independently. The confirmation of a LTP fracture was based on the consensus of the axial images by the two radiologists. The results of 3D CT volume rendering images were compared with the axial images and the diagnostic powers (sensitivity, specificity, and accuracy) were calculated. Seven of the 42 patients had twenty five lumbar transverse process fractures. The diagnostic power of the 3D CT volume rendering technique is as accurate as axial images. Reader 1, sensitivity 96%, specificity 100%, accuracy 99.9%; and Reader 2 sensitivity 100%, specificity 99.8%, accuracy 99.8%. The accordance of the two radiologists was 99.8%. 3D CT volume rendering images can alternate axial images to detect lumbar transverse process fractures with good image quality.

  7. Bronchial and non-bronchial systemic arteries: value of multidetector CT angiography in diagnosis and angiographic embolisation feasibility analysis

    International Nuclear Information System (INIS)

    Lin, Yuning; Chen, Ziqian; Yang, Xizhang; Zhong, Qun; Zhang, Hongwen; Yang, Li; Xu, Shangwen; Li, Hui

    2013-01-01

    The aim of this study is to evaluate the diagnostic performance of multidetector CT angiography (CTA) in depicting bronchial and non-bronchial systemic arteries in patients with haemoptysis and to assess whether this modality helps determine the feasibility of angiographic embolisation. Fifty-two patients with haemoptysis between January 2010 and July 2011 underwent both preoperative multidetector CTA and digital subtraction angiography (DSA) imaging. Diagnostic performance of CTA in depicting arteries causing haemoptysis was assessed on a per-patient and a per-artery basis. The feasibility of the endovascular treatment evaluated by CTA was analysed. Sensitivity, specificity, and positive and negative predictive values for those analyses were determined. Fifty patients were included in the artery-presence-number analysis. In the per-patient analysis, neither CTA (P=0.25) nor DSA (P=1.00) showed statistical difference in the detection of arteries causing haemoptysis. The sensitivity, specificity, and positive and negative predictive values were 94%, 100%, 100%, and 40%, respectively, for the presence of pathologic arteries evaluated by CTA, and 98%, 100%, 100%, and 67%, respectively, for DSA. On the per-artery basis, CTA correctly identified 97% (107/110). Fifty-two patients were included in the feasibility analysis. The performance of CTA in predicting the feasibility of angiographic embolisation was not statistically different from the treatment performed (P=1.00). The sensitivity, specificity, and positive and negative predictive values were 96%, 80%, 98% and 67%, respectively, for CTA. Multidetector CTA is an accurate imaging method in depicting the presence and number of arteries causing haemoptysis. This modality is also useful for determining the feasibility of angiographic embolisation for haemoptysis.

  8. Bronchial and non-bronchial systemic arteries: value of multidetector CT angiography in diagnosis and angiographic embolisation feasibility analysis.

    Science.gov (United States)

    Lin, Yuning; Chen, Ziqian; Yang, Xizhang; Zhong, Qun; Zhang, Hongwen; Yang, Li; Xu, Shangwen; Li, Hui

    2013-12-01

    The aim of this study is to evaluate the diagnostic performance of multidetector CT angiography (CTA) in depicting bronchial and non-bronchial systemic arteries in patients with haemoptysis and to assess whether this modality helps determine the feasibility of angiographic embolisation. Fifty-two patients with haemoptysis between January 2010 and July 2011 underwent both preoperative multidetector CTA and digital subtraction angiography (DSA) imaging. Diagnostic performance of CTA in depicting arteries causing haemoptysis was assessed on a per-patient and a per-artery basis. The feasibility of the endovascular treatment evaluated by CTA was analysed. Sensitivity, specificity, and positive and negative predictive values for those analyses were determined. Fifty patients were included in the artery-presence-number analysis. In the per-patient analysis, neither CTA (P = 0.25) nor DSA (P = 1.00) showed statistical difference in the detection of arteries causing haemoptysis. The sensitivity, specificity, and positive and negative predictive values were 94%, 100%, 100%, and 40%, respectively, for the presence of pathologic arteries evaluated by CTA, and 98%, 100%, 100%, and 67%, respectively, for DSA. On the per-artery basis, CTA correctly identified 97% (107/110). Fifty-two patients were included in the feasibility analysis. The performance of CTA in predicting the feasibility of angiographic embolisation was not statistically different from the treatment performed (P = 1.00). The sensitivity, specificity, and positive and negative predictive values were 96%, 80%, 98% and 67%, respectively, for CTA. Multidetector CTA is an accurate imaging method in depicting the presence and number of arteries causing haemoptysis. This modality is also useful for determining the feasibility of angiographic embolisation for haemoptysis. © 2013 The Authors. Journal of Medical Imaging and Radiation Oncology © 2013 The Royal Australian and New Zealand College of Radiologists.

  9. Diagnostic accuracy of 64-slice multidetector CT for detection of in-stent restenosis in an unselected, consecutive patient population

    Energy Technology Data Exchange (ETDEWEB)

    Haraldsdottir, Sigurdis, E-mail: sigurdisha@gmail.com [Boston Medical Center, 72 East Concord Street (Evans 124), Boston, MA, 02118 (United States); Gudnason, Thorarinn, E-mail: thorgudn@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Sigurdsson, Axel F., E-mail: axelfsig@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gudjonsdottir, Jonina, E-mail: jonina@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Lehman, Sam J., E-mail: slehman@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Eyjolfsson, Kristjan, E-mail: kristey@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Scheving, Sigurpall S., E-mail: sigurpal@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland); Gibson, C. Michael, E-mail: mgibson@perfuse.org [Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02115 (United States); Hoffmann, Udo, E-mail: uhoffmann@partners.org [Massachusetts General Hospital, 165 Cambridge Street, Suite 400, Boston, MA 02114 (United States); Jonsdottir, Birna, E-mail: birna@rd.is [Rontgen Domus Medica, Egilsgata 3, 101 Reykjavik (Iceland); Andersen, Karl, E-mail: andersen@landspitali.is [Landspitali University Hospital, Hringbraut, 101 Reykjavik (Iceland)

    2010-11-15

    Objectives: To investigate the diagnostic accuracy of 64-slice multidetector computed tomography (64-CT) for detection of in-stent restenosis (ISR) in an unselected, consecutive patient population. Background: Detection of in-stent restenosis by cardiac CT would be a major advance for the evaluation of patients suspected of having ISR. However, the diagnostic accuracy of current generation 64-CT in this context is not fully established. Methods: We conducted a prospective study on patients with stable angina or acute coronary syndrome with no prior history of coronary artery disease. Six months after percutaneous coronary intervention (PCI) with stent placement they underwent a 64-CT scan (Toshiba Multi-Slice Aquilion 64) and consequently a repeat coronary angiography for comparison. Cardiac CT data sets were analyzed for the presence of in-stent restenosis by two independent expert readers blinded to the coronary angiographic data. Results: Ninety-three patients with a total of 140 stents were evaluated. Males comprised 82% of the study group and the mean age was 63 {+-} 10 years. The mean time from PCI to the repeat coronary angiography was 208 {+-} 37 days and the mean time from 64-CT to repeat coronary angiography was 3.7 {+-} 4.9 days. The restenosis rate according to coronary angiography was 26%. Stent diameter, strut thickness, heart rate and body mass index (BMI) significantly affected image quality. The sensitivity, specificity, positive and negative predictive values of 64-CT for detection of in-stent restenosis were 27%, 95%, 67% and 78%, respectively. Conclusions: Current generation, 64-slice CT, remains limited in its ability to accurately detect in-stent restenosis.

  10. A comparative study of FDG PET/CT and enhanced multi-detector CT for detecting liver metastasis according to the size and location.

    Science.gov (United States)

    Park, Jung Mi; Kim, Il Young; Kim, Sang Won; Lee, Sang Mi; Kim, Hyun Gi; Kim, Shin Young; Shin, Hyung Chul

    2013-04-01

    The aim of this study was to compare the diagnosability between (18)F-fluorodeoxyglucose (FDG) PET/CT and enhanced multi-detector CT (MDCT) for the detection of liver metastasis (LM) according to the size and location in liver and to evaluate standard maximum standardized uptake values (SUVmax) of all liver metastatic lesions. One hundred two consecutive patients with malignancy who underwent both FDG PET/CT and MDCT for LM evaluation were retrospectively reviewed. Among them, 56 patients with LM were enrolled in this study. LM was confirmed by follow-up imaging studies after at least 6 months or by histopathology. FDG PET/CT and MDCT images were visually analyzed using three-point scale by the consensus of two radiologists and two nuclear medicine physicians. The size and location (central vs. sub-capsular) of the all liver lesions were evaluated using MDCT images. Furthermore, SUVmax of all liver lesions on FDG PET/CT images were calculated. A total of 146 liver lesions were detected by FDG PET/CT and MDCT and 142 of the lesions were diagnosed as LM. The detection rates of MDCT and FDG PET/CT for LM by visual analysis were 77 and 78%, respectively. There was no significant difference of detection rate according to the overall location and size of the lesions. However, FDG PET/CT was more sensitive than MDCT for detecting small and sub-capsular LM. The detection rate of FDG PET/CT for LM was 68% by the cutoff SUVmax of 2.7. Although the diagnosabilities of MDCT and FDG PET/CT for detecting LM were comparable, FDG PET/CT is superior to MDCT for detecting small LM located in the sub-capsular portion of liver.

  11. Clinical assessment of hypopharyngeal and laryngeal disorders by three-dimensional multidetector-row CT. Feasibility of imaging during phonation

    International Nuclear Information System (INIS)

    Tan, Xiaotian

    2002-01-01

    The hypopharynx and larynx can adapt their structures to physiological functions. To clarify the relation between morphologic changes and the development of pharyngeal and laryngeal disorders, images of the hypopharynx and larynx were obtained by multidetector-row CT (MD-CT) during phonation and quiet breathing. The clinical usefulness of such imaging study was assessed by comparing the images taken in the two phases. The study included 23 subjects, 20 patients with a hypopharyngeal or laryngeal disorder and 3 healthy volunteers. MD-CT scanning of the hypopharynx and larynx was not influenced by breathing and body movement. The volume rendering (VR) method was useful in that three-dimensional imaging could visualize the internal structure of the hypopharynx and larynx. Thus, the volume rendering method can be regarded as a virtual three-dimensional method. The normal anatomic structure of the hypopharynx and larynx were depicted in full and three-dimensionally. The extent of hypopharyngeal and laryngeal cancer was shown clearly. Edema due to paralysis of recurrent nerve was demonstrated in full and three-dimensionally, providing for functional diagnosis. In the case of mucosal edema caused by trauma, the extent of the edema and its effect on the airway were clearly observed. These results suggest that MD-CT with three-dimensional imaging during phonation is useful in the diagnosis of hypopharyngeal and laryngeal disorders. (author)

  12. Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography

    International Nuclear Information System (INIS)

    Byun, Sung Su; Kim, Youn Jeong; Chun, Yong Sun; Kim, Won Hong; Kim, Jeong Ho; Park, Chul Hi

    2008-01-01

    This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. The z-axis length (mean±standard deviation) of the beam hardening artifact was 4.5±0.8 cm in the arthroplastic knees and 3.9±2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating postarthroplasty patients

  13. Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Sung Su; Kim, Youn Jeong; Chun, Yong Sun; Kim, Won Hong [Inha University, College of Medicine, Incheon (Korea, Republic of); Kim, Jeong Ho; Park, Chul Hi [Gachon University, Gil Medical Center, Incheon (Korea, Republic of)

    2008-02-15

    This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. The z-axis length (mean{+-}standard deviation) of the beam hardening artifact was 4.5{+-}0.8 cm in the arthroplastic knees and 3.9{+-}2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating postarthroplasty patients.

  14. Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning

    International Nuclear Information System (INIS)

    Chung, Gi Chung; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Effective doses in μSv (E2007) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

  15. Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Gi Chung; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-03-15

    This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Effective doses in {mu}Sv (E2007) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

  16. Multidetector-row CT finding of gastric cystic lymphangioma: A case report

    International Nuclear Information System (INIS)

    Kang, Tae Wook; Lee, Soon Jin; Song, Hye Jong

    2008-01-01

    Cystic lymphangioma is a rare benign submucosal tumor of the stomach thought to originate from sequestered lymphatic tissue that fails to communicate with the normal lymphatic system. The most commonly used method of evaluation for cystic lymphangioma of the stomach is an endoscopic ultrasonography. We report the multidetector-row computed tomography findings of a cystic lymphangioma of the stomach in a 46-year-old man along with a literature review

  17. Multidetector CT diagnosis of massive hemobilia due to gallbladder polyposis in a child with metachromatic leukodystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Wanner, Matthew R.; Karmazyn, Boaz [Indiana University School of Medicine, Riley Hospital for Children, Department of Radiology and Imaging Sciences, Indianapolis, IN (United States); Fan, Rong [Indiana University School of Medicine, Riley Hospital for Children, Department of Pathology and Laboratory Medicine, Indianapolis, IN (United States)

    2015-12-15

    Hemobilia secondary to gallbladder polyposis is rare in children but has been reported in a few children with metachromatic leukodystrophy. We present a case with preoperative multidetector computed tomography (MDCT) diagnosis of massive hemobilia caused by gallbladder polyposis in a patient with metachromatic leukodystrophy. Our report highlights the importance of both awareness of the association of gallbladder polyposis with other syndromes such as metachromatic leukodystrophy as well as the possibility of this entity presenting with life-threatening bleeding. (orig.)

  18. Abdominal multi-detector row CT: Effectiveness of determining contrast medium dose on basis of body surface area

    International Nuclear Information System (INIS)

    Onishi, Hiromitsu; Murakami, Takamichi; Kim, Tonsok; Hori, Masatoshi; Osuga, Keigo; Tatsumi, Mitsuaki; Higashihara, Hiroki; Maeda, Noboru; Tsuboyama, Takahiro; Nakamoto, Atsushi; Tomoda, Kaname; Tomiyama, Noriyuki

    2011-01-01

    Purpose: To investigate the validity of determining the contrast medium dose based on body surface area (BSA) for the abdominal contrast-enhanced multi-detector row CT comparing with determining based on body weight (BW). Materials and methods: Institutional review committee approval was obtained. In this retrospective study, 191 patients those underwent abdominal contrast-enhanced multi-detector row CT were enrolled. All patients received 96 mL of 320 mg I/mL contrast medium at the rate of 3.2 mL. The iodine dose required to enhance 1 HU of the aorta at the arterial phase and that of liver parenchyma at portal venous phase per BSA were calculated (EU BSA ) and evaluated the relationship with BSA. Those per BW were also calculated (EU BW ) and evaluated. Estimated enhancement values (EEVs) of the aorta and liver parenchyma with two protocols for dose decision based on BSA and BW were calculated and patient-to-patient variability was compared between two protocols using the Levene test. Results: The mean of EU BSA and EU BW were 0.0621 g I/m 2 /HU and 0.00178 g I/kg/HU for the aorta, and 0.342 g I/m 2 /HU and 0.00978 g I/kg/HU for the liver parenchyma, respectively. In the aortic enhancement, EU BSA was almost constant regardless of BSA, and the mean absolute deviation of the EEV with the BSA protocol was significantly lower than that with the BW protocol (P < .001), although there was no significant difference between two protocols in the hepatic parenchymal enhancement (P = .92). Conclusion: For the aortic enhancement, determining the contrast medium dose based on BSA was considered to improve patient-to-patient enhancement variability.

  19. Three-dimensional reconstructions of the orbital floor by volume-rendering of multidetector-row CT data

    International Nuclear Information System (INIS)

    Yoshikawa, Tetsuya; Miyajima, Akira; Fujita, Yuko; Yamada, Kazuo

    2011-01-01

    The advent of 3D-CT has made the evaluation of complicated facial fractures much easier than before. However, its use in injuries involving the orbital floor has been limited by the difficulty of visualizing the thin bony structures given artifacts caused by the partial volume effect. Nevertheless, high-technology machines such as multidetector-row CT (MDCT) and new-generation software have improved the quality of 3D imaging, and this paper describes a procedure for obtaining better visualization of the orbital floor using a MDCT scanner. Forty trauma cases were subject to MDCT: 13 with injury to the orbital floor, and 27 without. All scans were performed in the standard manner, at slice thicknesses of 0.5 mm. 3D-CT images were created overlooking the orbital floor including soft tissue to minimize the pseudo-foramen artifacts produced through volume rendering. Bone deficits, fracture lines, and grafted bone were visible in the 3D images, and visualization was supported by the ready creation of stereoscopic images from MDCT volume data. Measurement of the pseudo-foramen revealed approximately half the artifacts to be less than 5 mm in diameter, suggesting practicality of this method without subjecting the patient to undue increases in radiation exposure in the treatment of cases involving injury to the orbital floor. (author)

  20. Impact of the use of contrast-enhancement multidetector CT for acute appendicitis: a prospective comparison with the Alvarado score

    International Nuclear Information System (INIS)

    Choi, Mi Young; Yoon, Seong Eon; Lee, Young Hwan; Choi, Shi Sung; Park, Seong Hoon; Juhng, Seong Kwan; Yoon, Kwon Ha; Park, Seong Ho

    2007-01-01

    To determine the diagnostic performance of contrast-enhanced multidetector CT (MDCT) and the Alvarado score for acute appendicitis. MDCT and determination of the Alvarado score were prospectively performed in 282 patients with 146 pathologically proven cases of acute appendicitis and 136 pathologically proven or clinically diagnosed cases of non-acute appendicitis. To compare the diagnostic performance of MDCT and the Alvarado score, the patients were subdivided according to age and sex, and receiver operating characteristics (ROC) analysis and Spearman rank correlation were performed. ROC analysis revealed that the optimal cut off value of the CT appendicitis grades was 2 in all patients, resulting in a sensitivity of 96.6% and a specificity of 94.9%. The optimal cut off values of the Alvarado score was different according to age and sex, resulting in a sensitivity of 85.6% and a specificity of 48.5%. There was a significant correlation between the CT appendicitis grades and the surgical-pathological grades (r = 0.496, ρ < .0001). However, no significant correlation was observed between the Alvarado score and the surgical-pathological grades. Contrast-enhanced MDCT has a higher diagnostic accuracy and significant correlation with pathological findings than those of the Alvarado score in patients with acute appendicitis

  1. Impact of the use of contrast-enhancement multidetector CT for acute appendicitis: a prospective comparison with the Alvarado score

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Mi Young; Yoon, Seong Eon; Lee, Young Hwan; Choi, Shi Sung; Park, Seong Hoon; Juhng, Seong Kwan; Yoon, Kwon Ha [Wonkwang University School of Medicine, Iksan (Korea, Republic of); Park, Seong Ho [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2007-12-15

    To determine the diagnostic performance of contrast-enhanced multidetector CT (MDCT) and the Alvarado score for acute appendicitis. MDCT and determination of the Alvarado score were prospectively performed in 282 patients with 146 pathologically proven cases of acute appendicitis and 136 pathologically proven or clinically diagnosed cases of non-acute appendicitis. To compare the diagnostic performance of MDCT and the Alvarado score, the patients were subdivided according to age and sex, and receiver operating characteristics (ROC) analysis and Spearman rank correlation were performed. ROC analysis revealed that the optimal cut off value of the CT appendicitis grades was 2 in all patients, resulting in a sensitivity of 96.6% and a specificity of 94.9%. The optimal cut off values of the Alvarado score was different according to age and sex, resulting in a sensitivity of 85.6% and a specificity of 48.5%. There was a significant correlation between the CT appendicitis grades and the surgical-pathological grades (r = 0.496, {rho} < .0001). However, no significant correlation was observed between the Alvarado score and the surgical-pathological grades. Contrast-enhanced MDCT has a higher diagnostic accuracy and significant correlation with pathological findings than those of the Alvarado score in patients with acute appendicitis.

  2. Coronary imaging quality in routine ECG-gated multidetector CT examinations of the entire thorax: preliminary experience with a 64-slice CT system in 133 patients

    International Nuclear Information System (INIS)

    Delhaye, Damien; Remy-Jardin, Martine; Salem, Randa; Teisseire, Antoine; Khalil, Chadi; Remy, Jacques; Delannoy-Deken, Valerie; Duhamel, Alain

    2007-01-01

    To evaluate image quality in the assessment of the coronary arteries during routine ECG-gated multidetector CT (MDCT) of the chest. One hundred and thirty three patients in sinus rhythm underwent an ECG-gated CT angiographic examination of the entire chest without β-blockers with a 64-slice CT system. In 127 patients (95%), it was possible to assess the coronary arteries partially or totally; coronary artery imaging failed in six patients (5%), leading to a detailed description of the coronary arteries in 127 patients. Considering ten coronary artery segments per patient, 75% of coronary segments were assessable (948/1270 segments). When the distal segments were excluded from the analysis (i.e., seven coronary segments evaluated per patient), the percentage of assessable segments was 86% (768/889 proximal and mid coronary segments) and reached 93% (474/508) when assessing proximal segments exclusively. The mean number of assessable segments was significantly higher in patients with a heart rate ≤80 bpm (n=95) than in patients with a heart rate >80 bpm (n=38) (p<0.002). Proximal and mid-coronary segments can be adequately assessed during a whole-chest ECG-gated CT angiographic examination without administration of β-blockers in patients with a heart rate below 80 bpm. (orig.)

  3. The in vivo relationship between cross-sectional area and CT dose index in abdominal multidetector CT with automatic exposure control

    Energy Technology Data Exchange (ETDEWEB)

    Meeson, S; Alvey, C M; Golding, S J, E-mail: stuart.meeson@nds.ox.ac.u [Radiology Group, Nuffield Department of Surgery, University of Oxford, John Radcliffe Hospital, Oxford OX3 9DU (United Kingdom)

    2010-06-15

    The relationship between patient cross-sectional area and both volume CT dose index (CTDI) and dose length product was explored for abdominal CT in vivo, using a 16 multidetector row CT (MDCT) scanner with automatic exposure control. During a year-long retrospective survey of patients with MDCT for symptoms of abdominal sepsis, cross-sectional areas were estimated using customised ellipses at the level of the middle of vertebra L3. The relationship between cross-sectional area and the exposure parameters was explored. Scans were performed using a LightSpeed 16 (GE Healthcare Medical Systems, Milwaukee, WI) operated with tube current modulation. From a survey of 94 patients it was found that the CTDI increased with the increase in patient cross-sectional area. The relationship was logarithmic rather than linear, with a least-squares fit to the data (R{sup 2} = 0.80). For abdominal CT the cross-sectional area gave a measure of patient size based on the region of the body to be exposed. Exposure parameters increased with increasing cross-sectional area and the greater radiation exposure of larger patients was partly a consequence of their size. Given increasing obesity levels we believe that cross-sectional area and scan length should be added to future dose surveys, allowing patient size to be considered as a factor of relevance when examining population doses.

  4. Monte Carlo simulations in multi-detector CT (MDCT) for two PET/CT scanner models using MASH and FASH adult phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Belinato, W., E-mail: wbfisica@gmail.com [Bahia Federal Institute of Education, Science and Technology – IFBA, Vitória da Conquista, 45.100-000 (Brazil); Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil); Santos, W.S. [Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil); Paschoal, C.M.M., E-mail: cinthiam.paschoal@gmail.com [Department of Civil Engineering, Vale do Acarau State University – UVA, Sobral 62.040-730 (Brazil); Souza, D.N. [Department of Physics, Federal University of Sergipe – UFS, São Cristóvão, 49.100-000 (Brazil)

    2015-06-01

    The combination of positron emission tomography (PET) and computed tomography (CT) has been extensively used in oncology for diagnosis and staging of tumors, radiotherapy planning and follow-up of patients with cancer, as well as in cardiology and neurology. This study determines by the Monte Carlo method the internal organ dose deposition for computational phantoms created by multidetector CT (MDCT) beams of two PET/CT devices operating with different parameters. The different MDCT beam parameters were largely related to the total filtration that provides a beam energetic change inside the gantry. This parameter was determined experimentally with the Accu-Gold Radcal measurement system. The experimental values of the total filtration were included in the simulations of two MCNPX code scenarios. The absorbed organ doses obtained in MASH and FASH phantoms indicate that bowtie filter geometry and the energy of the X-ray beam have significant influence on the results, although this influence can be compensated by adjusting other variables such as the tube current–time product (mAs) and pitch during PET/CT procedures.

  5. Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT

    International Nuclear Information System (INIS)

    Angel, Erin; Yaghmai, Nazanin; Jude, Cecilia Matilda; DeMarco, John J; Cagnon, Christopher H; Goldin, Jonathan G; McNitt-Gray, Michael F; Primak, Andrew N; McCollough, Cynthia H; Stevens, Donna M; Cody, Dianna D

    2009-01-01

    Tube current modulation was designed to reduce radiation dose in CT imaging while maintaining overall image quality. This study aims to develop a method for evaluating the effects of tube current modulation (TCM) on organ dose in CT exams of actual patient anatomy. This method was validated by simulating a TCM and a fixed tube current chest CT exam on 30 voxelized patient models and estimating the radiation dose to each patient's glandular breast tissue. This new method for estimating organ dose was compared with other conventional estimates of dose reduction. Thirty detailed voxelized models of patient anatomy were created based on image data from female patients who had previously undergone clinically indicated CT scans including the chest area. As an indicator of patient size, the perimeter of the patient was measured on the image containing at least one nipple using a semi-automated technique. The breasts were contoured on each image set by a radiologist and glandular tissue was semi-automatically segmented from this region. Previously validated Monte Carlo models of two multidetector CT scanners were used, taking into account details about the source spectra, filtration, collimation and geometry of the scanner. TCM data were obtained from each patient's clinical scan and factored into the model to simulate the effects of TCM. For each patient model, two exams were simulated: a fixed tube current chest CT and a tube current modulated chest CT. X-ray photons were transported through the anatomy of the voxelized patient models, and radiation dose was tallied in the glandular breast tissue. The resulting doses from the tube current modulated simulations were compared to the results obtained from simulations performed using a fixed mA value. The average radiation dose to the glandular breast tissue from a fixed tube current scan across all patient models was 19 mGy. The average reduction in breast dose using the tube current modulated scan was 17%. Results were

  6. Multi-detector row CT colonography: effect of collimation, pitch, and orientation on polyp detection in a human colectomy specimen.

    Science.gov (United States)

    Taylor, Stuart A; Halligan, Steve; Bartram, Clive I; Morgan, Paul R; Talbot, Ian C; Fry, Nicola; Saunders, Brian P; Khosraviani, Kirosh; Atkin, Wendy

    2003-10-01

    To investigate the effects of orientation, collimation, pitch, and tube current setting on polyp detection at multi-detector row computed tomographic (CT) colonography and to determine the optimal combination of scanning parameters for screening. A colectomy specimen containing 117 polyps of different sizes was insufflated and imaged with a multi-detector row CT scanner at various collimation (1.25 and 2.5 mm), pitch (3 and 6), and tube current (50, 100, and 150 mA) settings. Two-dimensional multiplanar reformatted images and three-dimensional endoluminal surface renderings from the 12 resultant data sets were examined by one observer for the presence and conspicuity of polyps. The results were analyzed with Poisson regression and logistic regression to determine the effects of scanning parameters and of specimen orientation on polyp detection. The percentage of polyps that were detected significantly increased when collimation (P =.008) and table feed (P =.03) were decreased. Increased tube current resulted in improved detection only of polyps with a diameter of less than 5 mm. Polyps of less than 5 mm were optimally depicted with a collimation of 1.25 mm, a pitch of 3, and a tube current setting of 150 mA; polyps with a diameter greater than 5 mm were adequately depicted with 1.25-mm collimation and with either pitch setting and any of the three tube current settings. Small polyps in the transverse segment (positioned at a 90 degrees angle to the z axis of scanning) were significantly less visible than those in parallel or oblique orientations (P detector row CT is highly dependent on collimation, pitch, and, to a lesser extent, tube current. Collimation of 1.25 mm, combined with pitch of 6 and tube current of 50 mA, provides for reliable detection of polyps 5 mm or larger while limiting the effective radiation dose. Polyps smaller than 5 mm, however, may be poorly depicted with use of these settings in the transverse colon. Copyright RSNA, 2003

  7. Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique

    International Nuclear Information System (INIS)

    Tsai, I.C.; Lee, Tain; Chen, Min-Chi; Fu, Yun-Ching; Jan, Sheng-Lin; Wang, Chung-Chi; Chang, Yen

    2007-01-01

    Multidetector CT (MDCT) seems to be a promising tool for detection of neonatal coronary arteries, but whether the ECG-gated or non-ECG-gated technique should be used has not been established. To compare the detection rate and image quality of neonatal coronary arteries on MDCT using ECG-gated and non-ECG-gated techniques. Twelve neonates with complex congenital heart disease were included. The CT scan was acquired using an ECG-gated technique, and the most quiescent phase of the RR interval was selected to represent the ECG-gated images. The raw data were then reconstructed without the ECG signal to obtain non-ECG-gated images. The detection rate and image quality of nine coronary artery segments in the two sets of images were then compared. A two-tailed paired t test was used with P values <0.05 considered as statistically significant. In all coronary segments the ECG-gated technique had a better detection rate and produced images of better quality. The difference between the two techniques ranged from 25% in the left main coronary artery to 100% in the distal right coronary artery. For neonates referred for MDCT, if evaluation of coronary artery anatomy is important for the clinical management or surgical planning, the ECG-gated technique should be used because it can reliably detect the coronary arteries. (orig.)

  8. Estimation of eye lens dose during brain scans using Gafchromic XR-QA2 film in various multidetector CT scanners

    International Nuclear Information System (INIS)

    Akhilesh, Philomina; Jamhale, Shramika H.; Sharma, S.D.; Kumar, Rajesh; Datta, D.; Kulkarni, Arti R.

    2017-01-01

    The purpose of this study was to estimate eye lens dose during brain scans in 16-, 64-, 128- and 256-slice multidetector computed tomography (CT) scanners in helical acquisition mode and to test the feasibility of using radiochromic film as eye lens dosemeter during CT scanning. Eye lens dose measurements were performed using Gafchromic XR-QA2 film on a polystyrene head phantom designed with outer dimensions equivalent to the head size of a reference Indian man. The response accuracy of XR-QA2 film was validated by using thermoluminescence dosemeters. The eye lens dose measured using XR-QA2 film on head phantom for plain brain scanning in helical mode ranged from 43.8 to 45.8 mGy. The XR-QA2 film measured dose values were in agreement with TLD measured dose values within a maximum variation of 8.9%. The good correlation between the two data sets confirms the viability of using XR-QA2 film for eye lens dosimetry. (authors)

  9. Detection of the anatomic structure and pathology in animal lung specimens: comparison of micro CT and multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Kun Young [National Cancer Center, Goyang (Korea, Republic of); Lee, Hyun Ju; Lee, Chang Hyun; Son, Kyu Ri; Goo, Jin Mo; Im, Jung Gi [Seoul National University Hospital and the Institute of Radiation Medicine, Seoul (Korea, Republic of); Seo, Joon Beom [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2006-05-15

    We wanted to compare the capability of micro CT and the clinically available thin-slice multi-detector row CT (MDCT) for demonstrating fine anatomic structures and pathological lesions in formalin-fixed lung specimens. The porcine lung with shark liver oil-induced lipoid pneumonia and the canine lung with pulmonary paragonimiasis were fixed by ventilating them with formalin vapor, and they were then sliced into one-centimeter thick sections. Micro CT (section thickness, 18 micrometer) and MDCT (section thickness, 0.75 mm) images were acquired in four of the lung slices of the lipoid pneumonia specimen and in five of the lung slices of the paragonimiasis specimen. On 62 pairs of micro CT and MDCT images, 169 pairs of rectangular ROIs were manually drawn in the corresponding locations. Two chest radiologists recorded the detectability of three kinds of anatomic structures (lobular core structure, interlobular septum and small bronchiolar lumen) and two kinds of pathological lesions (ground-glass opacity and consolidation) with using a five-point scale. The statistical comparison was performed by using the Wilcoxon signed rank test. Interobserver agreement was evaluated with kappa statistics. For all observers, all the kinds of anatomic structures and pathological lesions were detected better on the micro CT images than on the MDCT images ({rho} < 0.01). Agreement was fair between two observers ({kappa} = 0.38, {rho} < 0.001). The fine anatomic structures and pathological lesions of the lung were more accurately demonstrated on micro CT than on thin-slice MDCT in the inflated and fixed lung specimens.

  10. Detection of the anatomic structure and pathology in animal lung specimens: comparison of micro CT and multi-detector row CT

    International Nuclear Information System (INIS)

    Lim, Kun Young; Lee, Hyun Ju; Lee, Chang Hyun; Son, Kyu Ri; Goo, Jin Mo; Im, Jung Gi; Seo, Joon Beom

    2006-01-01

    We wanted to compare the capability of micro CT and the clinically available thin-slice multi-detector row CT (MDCT) for demonstrating fine anatomic structures and pathological lesions in formalin-fixed lung specimens. The porcine lung with shark liver oil-induced lipoid pneumonia and the canine lung with pulmonary paragonimiasis were fixed by ventilating them with formalin vapor, and they were then sliced into one-centimeter thick sections. Micro CT (section thickness, 18 micrometer) and MDCT (section thickness, 0.75 mm) images were acquired in four of the lung slices of the lipoid pneumonia specimen and in five of the lung slices of the paragonimiasis specimen. On 62 pairs of micro CT and MDCT images, 169 pairs of rectangular ROIs were manually drawn in the corresponding locations. Two chest radiologists recorded the detectability of three kinds of anatomic structures (lobular core structure, interlobular septum and small bronchiolar lumen) and two kinds of pathological lesions (ground-glass opacity and consolidation) with using a five-point scale. The statistical comparison was performed by using the Wilcoxon signed rank test. Interobserver agreement was evaluated with kappa statistics. For all observers, all the kinds of anatomic structures and pathological lesions were detected better on the micro CT images than on the MDCT images (ρ < 0.01). Agreement was fair between two observers (κ = 0.38, ρ < 0.001). The fine anatomic structures and pathological lesions of the lung were more accurately demonstrated on micro CT than on thin-slice MDCT in the inflated and fixed lung specimens

  11. Cardiac carcinoid: tricuspid delayed hyperenhancement on cardiac 64-slice multidetector CT and magnetic resonance imaging.

    LENUS (Irish Health Repository)

    Martos, R

    2012-02-01

    INTRODUCTION: Carcinoid heart disease is a rare condition in adults. Its diagnosis can be easily missed in a patient presenting to a primary care setting. We revised the advantages of using coronary multidetector computed tomography (MDCT) and cardiac magnetic resonance imaging (MRI) in diagnosing this condition. MATERIALS AND METHODS: We studied a 65-year-old patient with carcinoid heart disease and right heart failure using transthoracic Doppler-echocardiogram, cardiac MDCT and MRI. Cardiac echocardiogram revealed marked thickening and retraction of the tricuspid leaflets with dilated right atrium and ventricle. Cardiac MDCT and MRI demonstrated fixation and retraction of the tricuspid leaflets with delayed contrast hyperenhancement of the tricuspid annulus. CONCLUSION: This case demonstrates fascinating imaging findings of cardiac carcinoid disease and highlights the increasing utility of contrast-enhanced MRI and cardiac MDCT in the diagnosis of this interesting condition.

  12. Missed rib fractures on evaluation of initial chest CT for trauma patients: pattern analysis and diagnostic value of coronal multiplanar reconstruction images with multidetector row CT.

    Science.gov (United States)

    Cho, S H; Sung, Y M; Kim, M S

    2012-10-01

    The objective of this study was to review the prevalence and radiological features of rib fractures missed on initial chest CT evaluation, and to examine the diagnostic value of additional coronal images in a large series of trauma patients. 130 patients who presented to an emergency room for blunt chest trauma underwent multidetector row CT of the thorax within the first hour during their stay, and had follow-up CT or bone scans as diagnostic gold standards. Images were evaluated on two separate occasions: once with axial images and once with both axial and coronal images. The detection rates of missed rib fractures were compared between readings using a non-parametric method of clustered data. In the cases of missed rib fractures, the shapes, locations and associated fractures were evaluated. 58 rib fractures were missed with axial images only and 52 were missed with both axial and coronal images (p=0.088). The most common shape of missed rib fractures was buckled (56.9%), and the anterior arc (55.2%) was most commonly involved. 21 (36.2%) missed rib fractures had combined fractures on the same ribs, and 38 (65.5%) were accompanied by fracture on neighbouring ribs. Missed rib fractures are not uncommon, and radiologists should be familiar with buckle fractures, which are frequently missed. Additional coronal imagescan be helpful in the diagnosis of rib fractures that are not seen on axial images.

  13. Gastrointestinal tract wall visualization and distention during abdominal and pelvic multidetector CT with a neutral barium sulphate suspension: comparison with positive barium sulphate suspension and with water.

    Science.gov (United States)

    Oliva, M R; Erturk, S M; Ichikawa, T; Rocha, T; Ros, P R; Silverman, S G; Mortele, K J

    2012-01-01

    When examining patients with contrast-enhanced multidetector-row CT, we determined if the stomach and small bowel were visualized and distended better with a neutral barium sulphate suspension than with positive barium sulphate suspension or water. After obtaining approval from our institutional review board, 156 patients (women: 84; mean age: 54 yrs) with no history of gastrointestinal tract disease were randomized prospectively to receive orally either 900 ml of neutral (0.1% w/v) barium sulphate suspension (n = 53), 900 ml of positive (2.1% w/v) barium sulphate suspension (n = 53), or 900 ml of water (n = 50), prior to undergoing contrast-enhanced abdominal and pelvic multidetector-row CT. Two independent radiologists evaluated the stomach, and small bowel, for luminal distension and wall visualization, using a five point scale. Results were compared using Kruskal-Wallis and Mann-Whitney U tests. The walls of the stomach, and small bowel were visualized better in patients who were administered neutral barium sulphate suspension than those who were administered either positive barium sulphate suspension (p barium sulphate suspension, the stomach and small bowel were distended better compared to patients administered water (p barium sulphate suspension (p contrast-enhanced abdominal and pelvic multidetector-row CT, orally administered neutral barium sulphate suspension allows the gastrointestinal tract to be visualized and distended better than either positive barium sulphate suspension, or water.

  14. The relationship between coronary artery calcification detected by non-gated multi-detector CT in patients with suspected ischemic heart disease and myocardial ischemia detected by thallium exercise stress testing

    International Nuclear Information System (INIS)

    Nishida, Chikako; Okajima, Kaoru; Yamamoto, Takashi; Hattori, Ryuichi; Kudo, Takashi; Nishimura, Yasumasa

    2005-01-01

    The objective of this study was to examine whether we could predict myocardial ischemia when coronary artery calcification is detected by non-gated multidetector CT in patients with suspected ischemic heart disease. Eighty-three patients suspected of having ischemic heart disease (55 men, 28 women; age range 36-83 years; mean age 68 years) underwent multidetector CT and Tl-201 single photon emission computed tomography. Prediction of myocardial ischemia by coronary arterial calcification detected on CT was evaluated by comparing the coronary artery territories that showed calcification with the area of myocardial ischemia determined by SPECT. The sensitivity, specificity, positive predictive value, and negative predictive value of multidetector CT for predicting myocardial ischemia were calculated. Coronary angiography was also examined and compared with multidetector CT. Risk factors, including hypertension, smoking, hyperlipidemia, diabetes, and family history, were compared for evidence of coronary artery calcification detected by multidetector CT and myocardial ischemia detected by thallium nuclear scans. For analysis by patients, the sensitivity, specificity, positive predictive value, and negative predictive value of coronary artery calcification for myocardial ischemia detection were 65, 63, 56, and 71%, respectively. Similarly, for analysis by coronary arterial territories, those values were 56, 77, 41 and 86%, respectively. Coronary stenosis on CAG was also related to the ischemia determined by SPECT and calcification on multidetector CT. Ischemia was better influenced by risk factors than was coronary arterial calcification. For analysis by coronary arterial territories, the specificity and negative predictive value of coronary arterial calcification seen by multidetector CT are relatively high. (author)

  15. Automated detection of lung nodules in multidetector CT: influence of different reconstruction protocols on performance of a software prototype

    International Nuclear Information System (INIS)

    Gurung, J.; Maataoui, A.; Khan, M.; Wetter, A.; Harth, M.; Jacobi, V.; Vogl, T.J.

    2006-01-01

    Purpose: To evaluate the accuracy of software for computer-aided detection (CAD) of lung nodules using different reconstruction slice thickness protocols in multidetector CT. Materials and Methods: Raw image data sets for 15 patients who had undergone 16-row multidetector CT (MDCT) for known pulmonary nodules were reconstructed at a reconstruction thickness of 5.0, 2.0 and 1.0 mm with a reconstruction increment of 1.5, 1.0 and 0.5 mm, respectively. The ''Nodule Enhanced Viewing'' (NEV) tool of LungCare for computer-aided detection of lung nodules was applied to the reconstructed images. The reconstructed images were also blinded and then evaluated by 2 radiologists (A and B). Data from the evaluating radiologists and CAD was then compared to an independent reference standard established using the consensus of 2 independent experienced chest radiologists. The eligible nodules were grouped according to their size (diameter >10, 5 - 10, <5 mm) for assessment. Statistical analysis was performed using the receiver operating characteristic (ROC) curve analysis, t-test and two-rater Cohen's Kappa co-efficient. Results: A total of 103 nodules were included in the reference standard by the consensus panel. The performance of CAD was marginally lower than that of readers at a 5.0-mm reconstruction thickness (AUC = 0.522, 0.517 and 0.497 for A, B and CAD, respectively). In the case of 2.0-mm reconstruction slices, the performance of CAD was better than that of the readers (AUC = 0.524, 0.524 and 0.614 for A, B and CAD, respectively). CAD was found to be significantly superior to radiologists in the case of 1.0-mm reconstruction slices (AUC = 0.537, 0.531 and 0.675 for A, B and CAD, respectively). The sensitivity at a reconstruction thickness of 1.0 mm was determined to be 66.99%, 68.93% and 80.58% for A, B and CAD, respectively. The time required for detection was shortest for CAD at reconstruction slices of 1.0 mm (mean t = 4 min). The performance of radiologists was greatly

  16. Semi-quantitative assessment of tricuspid regurgitation on contrast-enhanced multidetector CT

    International Nuclear Information System (INIS)

    Groves, A.M.; Win, T.; Charman, S.C.; Wisbey, C.; Pepke-Zaba, J.; Coulden, R.A.

    2004-01-01

    AIM: To assess whether the early regurgitation of intravenous contrast medium into the inferior vena cava (IVC) and/or hepatic veins on computed tomography (CT), indicates tricuspid regurgitation (TR), and if so, whether it be used to grade severity. MATERIALS AND METHODS: We identified 86 consecutive patients that had been investigated for possible pulmonary endarterectomy at Papworth Hospital. From these, 61 patients were selected in whom CT, transthoracic echocardiography, and right heart catheterization (RHC) had been performed within 6 weeks. Using an arbitrary visual scale, the degree of TR assessed by intravenous contrast-enhanced CT was compared with echocardiography. Results were analysed using a kappa weighted statistical test. In addition, CT and echocardiographic assessments of TR severity were correlated with pulmonary artery pressure measurements obtained by RHC (Spearman's rank correlation coefficient). RESULTS: CT assessment of TR had a sensitivity of 90.4% and a specificity of 100% in detecting echocardiographic TR. For TR graded as more than trivial by echocardiography, sensitivity of CT was 100%. With respect to RHC data, the correlation between severity assessment of TR between CT and echocardiography using the Kappa weighted coefficient was 0.56 (moderately good agreement). With respect to RHC data, the correlation between mean pulmonary pressure and TR grading on CT and echocardiography was r=0.685 (p<0.001) and r=0.727 (p<0.001), respectively. CONCLUSION: Early opacification of the IVC or hepatic veins on first-pass contrast-enhanced CT almost invariably indicates TR. There is moderately good agreement between CT and echocardiographic assessment of the severity of TR. Both CT and echocardiographic grading of TR correlate well with RHC measurements of pulmonary artery pressure

  17. Fusion of CT Angiography or MR Angiography with Unenhanced CBCT and Fluoroscopy Guidance in Endovascular Treatments of Aorto-Iliac Steno-Occlusion: Technical Note on a Preliminary Experience

    Energy Technology Data Exchange (ETDEWEB)

    Ierardi, Anna Maria; Duka, Ejona [University of Insubria, Interventional Radiology, Department of Radiology (Italy); Radaelli, Alessandro [Philips Healthcare (Netherlands); Rivolta, Nicola; Piffaretti, Gabriele [University of Insubria, Vascular Surgery Department (Italy); Carrafiello, Gianpaolo, E-mail: gcarraf@gmail.com [University of Insubria, Interventional Radiology, Department of Radiology (Italy)

    2016-01-15

    AimTo evaluate the feasibility of image fusion (IF) of pre-procedural arterial-phase CT angiography or MR angiography with intra-procedural fluoroscopy for road-mapping in endovascular treatment of aorto-iliac steno-occlusive disease.Materials and MethodsBetween September and November, 2014, we prospectively evaluated 5 patients with chronic aorto-iliac steno-occlusive disease, who underwent endovascular treatment in the angiography suite. Fusion image road-mapping was performed using angiographic phase CT images or MR images acquired before and intra-procedural unenhanced cone-beam CT. Radiation dose of the procedure, volume of intra-procedural iodinated contrast medium, fluoroscopy time, and overall procedural time were recorded. Reasons for potential fusion imaging inaccuracies were also evaluated.ResultsImage co-registration and fusion guidance were feasible in all procedures. Mean radiation dose of the procedure was 60.21 Gycm2 (range 55.02–63.75 Gycm2). The mean total procedure time was 32.2 min (range 27–38 min). The mean fluoroscopy time was 12 min and 3 s. The mean procedural iodinated contrast material dose was 24 mL (range 20–40 mL).ConclusionsIF gives Interventional Radiologists the opportunity to use new technologies in order to improve outcomes with a significant reduction of contrast media administration.

  18. Fusion of CT Angiography or MR Angiography with Unenhanced CBCT and Fluoroscopy Guidance in Endovascular Treatments of Aorto-Iliac Steno-Occlusion: Technical Note on a Preliminary Experience

    International Nuclear Information System (INIS)

    Ierardi, Anna Maria; Duka, Ejona; Radaelli, Alessandro; Rivolta, Nicola; Piffaretti, Gabriele; Carrafiello, Gianpaolo

    2016-01-01

    AimTo evaluate the feasibility of image fusion (IF) of pre-procedural arterial-phase CT angiography or MR angiography with intra-procedural fluoroscopy for road-mapping in endovascular treatment of aorto-iliac steno-occlusive disease.Materials and MethodsBetween September and November, 2014, we prospectively evaluated 5 patients with chronic aorto-iliac steno-occlusive disease, who underwent endovascular treatment in the angiography suite. Fusion image road-mapping was performed using angiographic phase CT images or MR images acquired before and intra-procedural unenhanced cone-beam CT. Radiation dose of the procedure, volume of intra-procedural iodinated contrast medium, fluoroscopy time, and overall procedural time were recorded. Reasons for potential fusion imaging inaccuracies were also evaluated.ResultsImage co-registration and fusion guidance were feasible in all procedures. Mean radiation dose of the procedure was 60.21 Gycm2 (range 55.02–63.75 Gycm2). The mean total procedure time was 32.2 min (range 27–38 min). The mean fluoroscopy time was 12 min and 3 s. The mean procedural iodinated contrast material dose was 24 mL (range 20–40 mL).ConclusionsIF gives Interventional Radiologists the opportunity to use new technologies in order to improve outcomes with a significant reduction of contrast media administration

  19. Acute pulmonary embolism in the era of multi-detector CT: a reality in sub-Saharan Africa

    International Nuclear Information System (INIS)

    Tambe, Joshua; Moifo, Boniface; Fongang, Emmanuel; Guegang, Emilienne; Juimo, Alain Georges

    2012-01-01

    The advantages of multi-detector computed tomography (MDCT) have made it the imaging modality of choice for some patients with suspected cardiothoracic disease, of which pulmonary embolism (PE) is an exponent. The aim of this study was to assess the incidence of PE in patients with clinical suspicion of acute PE using MDCT in a sub-Saharan setting, and to describe the demographic characteristics of these patients. Consecutive records of patients who underwent MDCT pulmonary angiography for suspected acute PE over a two-year period at the Radiology Department of a university-affiliated hospital were systematically reviewed. All MDCT pulmonary angiograms were performed with a 16-detector computed tomography (CT) scanner using real-time bolus tracking technique. Authorization for the study was obtained from the institutional authorities. Forty-one MDCT pulmonary angiograms were reviewed of which 37 were retained. Of the 4 excluded studies, 3 were repeat angiograms and 1 study was not technically adequate. Twelve of 37 patients (32.4%) had CT angiograms that were positive for PE, of which 7 were males. The mean age of these patients was 47.6±10.5 years (age range from 33 to 65 years). Twenty five patients out of 37 (67.6%) had CT angiograms that were negative for PE. Eleven PE-positive patients (91.7%) had at least 1 identifiable thromboembolic risk factor whilst 5 PE-negative patients (20%) also had at least a thromboembolic risk factor. The relative risk of the occurrence of PE in patients with at least a thromboembolic risk factor was estimated at 14.4. Acute PE is a reality in sub-Saharan Africa, with an increased likelihood of MDCT evidence in patients with clinical suspicion of PE who have at least a thromboembolic risk factor. The increasing availability of MDCT will help provide more information on the occurrence of PE in these settings

  20. Comparison of Multidetector CT and Gadobutrol-Enhanced MR Imaging for Evaluation of Small, Solid Pancreatic Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Tae Won [Department of Radiology, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Lee, Jeong Min; Kim, Jung Hoon [Department of Radiology, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Yu, Mi Hye [Department of Radiology, Konkuk University Medical Center, Seoul 05030 (Korea, Republic of); Han, Joon Koo; Choi, Byung Ihn [Department of Radiology, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital, Seoul 03080 (Korea, Republic of)

    2016-11-01

    To compare multidetector computed tomography (MDCT) and MRI for lesion conspicuity, as well as the detection and characterization of small solid pancreatic lesions (SPLs). 193 patients with small SPLs (< 3 cm) and 52 patients with normal pancreas who underwent both multiphasic MDCT and gadobutrol-enhanced MRI were included in our study. Two radiologists blinded to the pathologic diagnoses independently reviewed those images, and determined the detection of 'SPL per se' and 'SPL in consideration of secondary features', the lesion conspicuity, the probability of pancreatic ductal adenocarcinoma (PDAC), and the most likely specific diagnosis. The sensitivity of MRI for 'detection of SPL per se' was significantly higher than that of CT in both reviewers: 92.7% (179/193) and 97.9% (189/193), respectively, for reviewer 1 (p = 0.031) and 90.7% (175/193) and 99.5% (192/193), respectively, for reviewer 2 (p < 0.001). In addition, MRI provided better lesion conspicuity than MDCT for both reviewers (p < 0.001). However, CT and MRI did not show significant difference in sensitivity for 'detection of SPL in consideration of secondary features', specificity for SPL detection, and differentiation of PDAC vs. non-PDAC (p > 0.05). The accuracies of CT and MRI for making a specific diagnosis were as follows: 85.7% (210/245) vs. 86.9% (213/245), respectively, for reviewer 1 (p = 0.736), and 91.8% (225/245) vs. 93.5% (229/245), respectively, for reviewer 2 (p = 0.454). MRI showed better lesion conspicuity than MDCT, but did not show significantly different diagnostic performance compared with MDCT for detecting and characterizing small SPLs.

  1. Case report: Isolated unilateral pulmonary vein atresia diagnosed on 128-slice multidetector CT

    Directory of Open Access Journals (Sweden)

    Rashmi Dixit

    2011-01-01

    Full Text Available Unilateral pulmonary venous atresia is an uncommon entity that is generally believed to be congenital. Most patients present in infancy or childhood with recurrent chest infections or hemoptysis. Pulmonary angiography is usually used for definitive diagnosis. However, the current multislice CT scanners may obviate the need for pulmonary angiography. We report two cases diagnosed using 128-slice CT angiography. On the CT angiography images both these cases demonstrated absent pulmonary veins on the affected side, with a small pulmonary artery and prominent bronchial or other systemic arterial supply.

  2. Preoperative assessment of hilar cholangiocarcinoma using multidetector-row CT. Correlation with histopathological findings

    International Nuclear Information System (INIS)

    Watadani, Takeyuki; Akahane, Masaaki; Ohtomo, Kuni; Yoshikawa, Takeharu

    2008-01-01

    Our aim was to investigate the diagnostic reliability of multidetector-row computed tomography (MDCT) for preoperative assessment of local tumoral spread in hilar cholangiocarcinoma. Thirteen of 30 consecutive patients with hilar cholangiocarcinoma who underwent surgery, excluding 17 patients who underwent biliary drainage or preoperative portal embolization, were retrospectively evaluated. Using MDCT systems of 4 detector rows or 16 detector rows, plain and dynamic contrast-enhanced images of three phases were obtained. Extent of tumor spread and lymph node metastasis were assessed with MDCT and compared with histopathological findings. The Bismuth-Corlette classification of hilar cholangiocarcinoma with MDCT were type I, 1 patient; type IIIa, 3 patients; type IIIb, 4 patients; and type IV, 5 patients; those with histopathological findings were type I, 1 patient; type IIIa, 2 patients; type IIIb, 4 patients; and type IV, 6 patients. One patient diagnosed as type IIIa with MDCT was pathologically diagnosed as type IV. Accuracy of MDCT in tumoral spread was 92.3%, although that of lymph node metastasis was 54%. MDCT is likely to play an important role in evaluation of focal lesion spread especially in intrapancreatic tumor invasion, although a greater number of cohort cases are necessary to clearly define its role. (author)

  3. Evaluation of the anomalous retroesophageal left brachiocephalic vein in Chinese children using multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Ming, Zhu; Aimin, Sun; Rui, He [Shanghai Children' s Medical Center, Department of Radiology, Shanghai (China)

    2009-04-15

    Anomalous retroesophageal left brachiocephalic vein is a very rare anomaly of the brachiocephalic vein. At the time of writing only one case had been reported worldwide. The purpose of this study was to report four cases of anomalous retroesophageal left brachiocephalic vein and to evaluate the utility of multidetector computed tomography (MDCT) for investigation of the anomaly. From June 2005 to May 2008, we examined 2,146 children with congenital heart disease and 4,082 children without congenital heart disease using MDCT. The patients ranged in age from 1 day to 12 years. Maximum intensity projection reconstruction was performed to show the brachiocephalic vein. A retroesophageal left brachiocephalic vein was found in 4 of the 2,146 patients (0.19%) with congenital heart disease and in 0 of the 4,082 patients without congenital heart disease. In all four patients, the condition was confirmed during surgery for the congenital heart disease. MDCT is a good modality for evaluating the anomalous retroesophageal left brachiocephalic vein. An anomalous retroesophageal left brachiocephalic vein was more common in patients with congenital heart disease. (orig.)

  4. Multi-detector CT features of acute intestinal ischemia and their prognostic correlations.

    Science.gov (United States)

    Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe

    2014-05-28

    Acute intestinal ischemia is an abdominal emergency occurring in nearly 1% of patients presenting with acute abdomen. The causes can be occlusive or non occlusive. Early diagnosis is important to improve survival rates. In most cases of late or missed diagnosis, the mortality rate from intestinal infarction is very high, with a reported value ranging from 60% to 90%. Multi-detector computed tomography (MDCT) is a fundamental imaging technique that must be promptly performed in all patients with suspected bowel ischemia. Thanks to the new dedicated reconstruction program, its diagnostic potential is much improved compared to the past and currently it is superior to that of any other noninvasive technique. The increased spatial and temporal resolution, high-quality multi-planar reconstructions, maximum intensity projections, vessel probe, surface-shaded volume rending and tissue transition projections make MDCT the gold standard for the diagnosis of intestinal ischemia, with reported sensitivity, specificity, positive and negative predictive values of 64%-93%, 92%-100%, 90%-100% and 94%-98%, respectively. MDCT contributes to appropriate treatment planning and provides important prognostic information thanks to its ability to define the nature and extent of the disease. The purpose of this review is to examine the diagnostic and prognostic role of MDCT in bowel ischemia with special regard to the state of art new reconstruction software.

  5. Accuracy of multidetector-row CT in diagnosing lymph node metastasis in patients with gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Takuro; Kurokawa, Yukinori; Takiguchi, Shuji; Miyazaki, Yasuhiro; Takahashi, Tsuyoshi; Yamasaki, Makoto; Miyata, Hiroshi; Nakajima, Kiyokazu; Mori, Masaki; Doki, Yuichiro [Osaka University, Graduate School of Medicine, Department of Gastroenterological Surgery, Suita, Osaka (Japan)

    2014-08-06

    The purpose of this study was to determine the optimal cut-off value of lymph node size for diagnosing metastasis in gastric cancer with multidetector-row computed tomography (MDCT) after categorizing perigastric lymph nodes into three regions. The study included 90 gastric cancer patients who underwent gastrectomy. The long-axis diameter (LAD) and short-axis diameter (SAD) of all visualized lymph nodes were measured with transverse MDCT images. The locations of lymph nodes were categorized into three regions: lesser curvature, greater curvature, and suprapancreatic. The diagnostic value of lymph node metastasis was assessed with receiver operating characteristic (ROC) analysis. The area under the curve was larger for SAD than LAD in all groups. The optimal cut-off values of SAD were determined as follows: overall, 9 mm; differentiated type, 9 mm; undifferentiated type, 8 mm; lesser curvature region, 7 mm; greater curvature region, 6 mm; and suprapancreatic region, 9 mm. The diagnostic accuracies for lymph node metastasis using individual cut-off values were 71.1 % based on histological type and 76.6 % based on region of lymph node location. The diagnostic accuracy of lymph node metastasis in gastric cancer was improved by using individual cut-off values for each lymph node region. (orig.)

  6. Comparison of neutral oral contrast versus positive oral contrast medium in abdominal multidetector CT

    International Nuclear Information System (INIS)

    Berther, Ralph; Eckhardt, Boris; Zollikofer, Christoph L.; Patak, Michael A.; Erturk, Sukru M.

    2008-01-01

    To determine whether neutral contrast agents with water-equivalent intraluminal attenuation can improve delineation of the bowel wall and increase overall image quality for a non-selected patient population, a neutral oral contrast agent (3% mannitol) was administered to 100 patients referred for abdominal multidetector row computed tomography (MDCT). Their results were compared with those of 100 patients given a positive oral contrast agent. Qualitative and quantitative measurements were done on different levels of the gastrointestinal tract by three experienced readers. Patients given the neutral oral contrast agent showed significant better qualitative results for bowel distension (P<0.001), homogeneity of the luminal content (P<0.001), delineation of the bowel-wall to the lumen (P<0.001) and to the mesentery (P<0.001) and artifacts (P<0.001), leading to a significant better overall image quality (P<0.001) than patients receiving positive oral contrast medium. The quantitative measurements revealed significant better distension (P<0.001) and wall to lumen delineation (P<0.001) for the patients receiving neutral oral contrast medium. The present results show that the neutral oral contrast agent (mannitol) produced better distension, better homogeneity and better delineation of the bowel wall leading to a higher overall image quality than the positive oral contrast medium in a non-selected patient population. (orig.)

  7. Detection, visualization and evaluation of anomalous coronary anatomy on 16-slice multidetector-row CT

    International Nuclear Information System (INIS)

    Ooijen, Peter M.A. van; Dorgelo, Joost; Oudkerk, Matthijs; Zijlstra, Felix

    2004-01-01

    Early identification and evaluation of relatively frequent anomalous coronary anatomy is quite relevant because of the occurrence of sudden cardiac death or related symptoms of myocardial ischemia. Selective coronary angiography (CAG) is invasive, expensive and cannot always provide the required information adequately. Recently, non-invasive imaging techniques such as magnetic resonance imaging and multidetector-row computed tomography (MDCT) have been shown to provide a good anatomical view of the coronary artery tree. This study aims to demonstrate the value of 16-MDCT for evaluation of anomalous coronary anatomy. In 13 patients scanned using 16-MDCT, six different coronary anomalies were diagnosed [two absent left main, one single vessel left coronary artery (LCA), three LCA originating from the right (two with interarterial course), six right coronary artery originating from the left, one double left anterior descending (LAD)]. Mean diagnostic quality, recorded by two observers using a 5-point scale (1= non-diagnostic to 5= excellent diagnostic quality), resulted in a mean score of 3.73 (SD 1.19) without any non-diagnostic result. MDCT offers an accurate diagnostic modality to visualize the origin and course of anomalous coronary arteries by a three-dimensional display of anatomy. Shortcomings in CAG can be overcome by the use of contrast-enhanced MDCT. (orig.)

  8. Contrast enhancement pattern on multidetector CT predicts malignancy in pancreatic endocrine tumours

    Energy Technology Data Exchange (ETDEWEB)

    Cappelli, Carla [University of Pisa, Diagnostic and Interventional Radiology, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Azienda Ospedaliero-Universitaria Pisana-Radiodiagnostica I, Pisa (Italy); Boggi, Ugo [University of Pisa, General and Transplant Surgery, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Mazzeo, Salvatore; Cervelli, Rosa; Contillo, Benedetta Pontillo; Bartolozzi, Carlo [University of Pisa, Diagnostic and Interventional Radiology, Department of Translational Research and New Technologies in Medicine and Surgery, Pisa (Italy); Campani, Daniela; Funel, Niccola [University of Pisa, Pathology, Department of Surgical, Medical, Molecular and Critical Area Pathology, Pisa (Italy)

    2014-12-02

    Preoperative suspicion of malignancy in pancreatic neuroendocrine tumours (pNETs) is mostly based on tumour size. We retrospectively reviewed the contrast enhancement pattern (CEP) of a series of pNETs on multiphasic multidetector computed tomography (MDCT), to identify further imaging features predictive of lesion aggressiveness. Sixty pNETs, diagnosed in 52 patients, were classified based on CEP as: type A showing early contrast enhancement and rapid wash-out; type B presenting even (B1) or only (B2) late enhancement. All tumours were resected allowing pathologic correlations. Nineteen pNETs showed type A CEP (5-20 mm), 29 type B1 CEP (5-80 mm) and 12 type B2 (15-100 mm). All tumours were classified as well differentiated tumours, 19 were benign (WDt-b), 15 with uncertain behaviour (WDt-u) and 26 carcinomas (WDC). None of A lesions were malignant (12 WDt-b; 7 WDt-u), all B2 lesions were WDC, 7 B1 lesions were WDt-b, 8 WDt-u and 14 WDC; 4/34 (12 %) lesions ≤2cm were WDC. CEP showed correlation with all histological prognostic indicators. Correlating with the lesion grading and other histological prognostic predictors, CEP may preoperatively suggest the behaviour of pNETs, assisting decisions about treatment. Moreover CEP allows recognition of malignant small tumours, incorrectly classified on the basis of their dimension. (orig.)

  9. Contrast enhancement pattern on multidetector CT predicts malignancy in pancreatic endocrine tumours

    International Nuclear Information System (INIS)

    Cappelli, Carla; Boggi, Ugo; Mazzeo, Salvatore; Cervelli, Rosa; Contillo, Benedetta Pontillo; Bartolozzi, Carlo; Campani, Daniela; Funel, Niccola

    2015-01-01

    Preoperative suspicion of malignancy in pancreatic neuroendocrine tumours (pNETs) is mostly based on tumour size. We retrospectively reviewed the contrast enhancement pattern (CEP) of a series of pNETs on multiphasic multidetector computed tomography (MDCT), to identify further imaging features predictive of lesion aggressiveness. Sixty pNETs, diagnosed in 52 patients, were classified based on CEP as: type A showing early contrast enhancement and rapid wash-out; type B presenting even (B1) or only (B2) late enhancement. All tumours were resected allowing pathologic correlations. Nineteen pNETs showed type A CEP (5-20 mm), 29 type B1 CEP (5-80 mm) and 12 type B2 (15-100 mm). All tumours were classified as well differentiated tumours, 19 were benign (WDt-b), 15 with uncertain behaviour (WDt-u) and 26 carcinomas (WDC). None of A lesions were malignant (12 WDt-b; 7 WDt-u), all B2 lesions were WDC, 7 B1 lesions were WDt-b, 8 WDt-u and 14 WDC; 4/34 (12 %) lesions ≤2cm were WDC. CEP showed correlation with all histological prognostic indicators. Correlating with the lesion grading and other histological prognostic predictors, CEP may preoperatively suggest the behaviour of pNETs, assisting decisions about treatment. Moreover CEP allows recognition of malignant small tumours, incorrectly classified on the basis of their dimension. (orig.)

  10. Multidetector CT angiography in living donor renal transplantation: accuracy and discrepancies in right venous anatomy.

    Science.gov (United States)

    Kulkarni, S; Emre, S; Arvelakis, A; Asch, W; Bia, M; Formica, R; Israel, G

    2011-01-01

    Multidetector computed tomography (MDCT) angiography is a reliable technique for assessing pre-operative renal anatomy in living kidney donors. The method has largely evolved into protocols that eliminate dedicated venous phase and instead utilize a combined arterial/venous phase to delineate arterial and venous anatomy simultaneously. Despite adoption of this protocol, there has been no study to assess its accuracy. To assess whether or not MDCT angiography compares favorably to intra-operative findings, 102 donors underwent MDCT angiography without a dedicated venous phase with surgical interpretation of renal anatomy. Anatomical variants included multiple arteries (12%), multiple veins (7%), early arterial bifurcation (13%), late venous confluence (5%), circumaortic renal veins (5%), retroaortic vein (1%), and ureteral duplication (2%). The sensitivity and specificity of multiple arterial anomalies were 100% and 97%, respectively. The sensitivity and specificity of multiple venous anomalies were 92% and 98%, respectively. The most common discrepancy was noted exclusively in the interpretation of right venous anatomy as it pertained to the renal vein/vena cava confluence (3%). MDCT angiography using a combined arterial/venous contrast-enhanced phase provides suitable depiction of renal donor anatomy. Careful consideration should be given when planning a right donor nephrectomy whether the radiographic interpretation is suggestive of a late confluence. © 2010 John Wiley & Sons A/S.

  11. Evaluation of the anomalous retroesophageal left brachiocephalic vein in Chinese children using multidetector CT

    International Nuclear Information System (INIS)

    Ming, Zhu; Aimin, Sun; Rui, He

    2009-01-01

    Anomalous retroesophageal left brachiocephalic vein is a very rare anomaly of the brachiocephalic vein. At the time of writing only one case had been reported worldwide. The purpose of this study was to report four cases of anomalous retroesophageal left brachiocephalic vein and to evaluate the utility of multidetector computed tomography (MDCT) for investigation of the anomaly. From June 2005 to May 2008, we examined 2,146 children with congenital heart disease and 4,082 children without congenital heart disease using MDCT. The patients ranged in age from 1 day to 12 years. Maximum intensity projection reconstruction was performed to show the brachiocephalic vein. A retroesophageal left brachiocephalic vein was found in 4 of the 2,146 patients (0.19%) with congenital heart disease and in 0 of the 4,082 patients without congenital heart disease. In all four patients, the condition was confirmed during surgery for the congenital heart disease. MDCT is a good modality for evaluating the anomalous retroesophageal left brachiocephalic vein. An anomalous retroesophageal left brachiocephalic vein was more common in patients with congenital heart disease. (orig.)

  12. Noninvasive method using multidetector CT for calculating the relative blood supply ratio of duplicated renal arteries in renal donors

    International Nuclear Information System (INIS)

    Kuwabara, Masatomo; Kim, Tonsok; Nakamura, Hironobu; Narumi, Yoshifumi; Takahashi, Satoru; Sato, Yoshinobu; Murakami, Takamichi

    2006-01-01

    The aim of this study was to evaluate the correlation between the renal artery cross-sectional area measured by multidetector computed tomography (MDCT) and the nephrogram area calculated by renal arteriography in potential living renal donors with duplicated renal arteries. Medical records of 18 patients with duplicated renal arteries who underwent both MDCT angiography and renal arteriography between 2001 and 2003 were retrospectively reviewed. All 20 kidneys were evaluated. Renal artery cross-sectional areas were measured using the workstation to which the CT data were transferred; the nephrogram areas on the digitized angiographic images were calculated using public domain software. Bland-Altman analysis was performed to compare the cross-sectional area ratio of the accessory arteries to the main renal arteries, with the ratios obtained from the nephrogram areas calculated from the arteriograms. The mean cross-sectional areas of the accessory and main renal arteries were 6.78 and 20.9 mm 2 , respectively. The ratio of the nephrogram areas calculated from the arteriograms ranged from 0.094 to 0.809. Bland-Altman analysis showed no significant difference. It is possible to predict the supply volume of accessory renal arteries by measuring the cross-sectional area of the accessory and main renal arteries in potential living renal donors. (author)

  13. Tracheal compression due to an elongated aortic arch in patients with congenital heart disease: evaluation using multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Noriko; Hayabuchi, Yasunobu; Inoue, Miki; Sakata, Miho; Nabo, Manal Mohamed Helmy; Nakagawa, Ryuji; Saijo, Takahiko; Kagami, Shoji [University of Tokushima, Department of Pediatrics, Tokushima (Japan)

    2009-10-15

    The airway can become obstructed as a result of compression by an elongated aortic arch. In this study we evaluated tracheal compression using multidetector-row CT in patients with congenital heart disease and an elongated aortic arch. The trachea was measured at the level of the aortic arch in 205 children and young adults and then the severity of tracheal compression was determined by measuring the tracheal diameter ratio (short axis diameter/long axis diameter). Patients were divided as follows: group I (normal aortic arch; n=166), group II (transversely running aortic arch; n=22), and group III (elongated aortic arch; n=17). From the viewpoint of the relationship of the great arteries, group II had D-malposition, and group III had L-malposition. Age, height, weight and body surface area were significantly correlated with the short and long axis diameter in group I. There was a negative correlation between tracheal diameter ratio and the physical size parameters. The tracheal diameter ratio in group III was 0.50{+-}0.13, which was significantly lower than in groups I and II (P<0.01 and 0.05, respectively). Even apparently asymptomatic patients with an elongated aortic arch can have tracheal compression. An elongated aortic arch may be a useful predictor of tracheal compression. (orig.)

  14. Evaluation of various image reconstruction parameters in lower extremity stents using multidetector-row CT angiography: initial findings

    International Nuclear Information System (INIS)

    Heuschmid, Martin; Wiesinger, Benjamin; Tepe, Gunnar; Luz, Oliver; Kopp, Andreas F.; Claussen, Claus D.; Duda, Stephan H.

    2007-01-01

    Image quality, visible lumen and patency of lower limb stents was assessed by multidetector-row computed tomography (MDCT) angiography using various reconstruction parameters and the results compared with conventional angiography. Fourteen patients (25 stents) were evaluated. From MDCT datasets, axial and coronal oblique reformations were reconstructed using differing reconstruction parameters (slice thickness, kernel, views). Artifacts and image quality were assessed using a five-degree scale (1=excellent, 5=poor). Visible stent diameter was measured. Stenosis severity was compared with calibrated catheter angiography. The image quality of medium and sharp image kernels were good/fair (1.9-2.4), while smooth kernel provided only acceptable/poor image quality (3.9-4.4). Coronal oblique images were rated superior to assess in-stent lumen rather than axial. Using medium and sharp kernels, the visible stent lumen was significantly greater than using smooth kernel (P<0.001). thirteen out of fourteen patients (24/25 stents) were correctly classified as patent. In one patient, in-stent stenosis (≥50%) was falsely diagnosed using CT angiography (CTA) with smooth kernel and was, therefore, rated as false positive. Coronal oblique views, as well as medium and sharp kernels, have shown the best results regarding image quality to assess stent patency in the lower limb. Therefore, MDCT could be a valuable non-invasive modality for stent imaging in the peripheral vasculature. (orig.)

  15. Anatomical variations of hepatic arterial system, coeliac trunk and renal arteries: an analysis with multidetector CT angiography.

    Science.gov (United States)

    Ugurel, M S; Battal, B; Bozlar, U; Nural, M S; Tasar, M; Ors, F; Saglam, M; Karademir, I

    2010-08-01

    The purpose of our investigation was to determine the anatomical variations in the coeliac trunk-hepatic arterial system and the renal arteries in patients who underwent multidetector CT (MDCT) angiography of the abdominal aorta for various reasons. A total of 100 patients were analysed retrospectively. The coeliac trunk, hepatic arterial system and renal arteries were analysed individually and anatomical variations were recorded. Statistical analysis of the relationship between hepatocoeliac variations and renal artery variations was performed using a chi(2) test. There was a coeliac trunk trifurcation in 89% and bifurcation in 8% of the cases. Coeliac trunk was absent in 1%, a hepatosplenomesenteric trunk was seen in 1% and a splenomesenteric trunk was present in 1%. Hepatic artery variation was present in 48% of patients. Coeliac trunk and/or hepatic arterial variation was present in 23 (39.7%) of the 58 patients with normal renal arteries, and in 27 (64.3%) of the 42 patients with accessory renal arteries. There was a statistically significant correlation between renal artery variations and coeliac trunk-hepatic arterial system variations (p = 0.015). MDCT angiography permits a correct and detailed evaluation of hepatic and renal vascular anatomy. The prevalence of variations in the coeliac trunk and/or hepatic arteries is increased in people with accessory renal arteries. For that reason, when undertaking angiographic examinations directed towards any single organ, the possibility of variations in the vascular structure of other organs should be kept in mind.

  16. Multidetector-row CT of right hemidiaphragmatic rupture caused by blunt trauma: a review of 12 cases

    International Nuclear Information System (INIS)

    Rees, O.; Mirvis, S.E.; Shanmuganathan, K.

    2005-01-01

    AIM: To determine the usefulness of multidetector-row CT (MDCT) with multiplanar reformatted (MPR) images in the sagittal and coronal plane in diagnosing acute right hemidiaphragmatic rupture. MATERIALS AND METHODS: Twelve patients were identified who received chest and abdominal MDCT after major blunt trauma diagnosed with right diaphragmatic injury. Sagittal and coronal reformations were performed in all cases. The images were retrospectively reviewed by two experienced radiologists for signs of right diaphragm injury, such as direct diaphragm discontinuity, the 'collar sign', the 'dependent viscera sign', and intra-thoracic location of herniated abdominal contents. RESULTS: Of the 12 cases of right hemidiaphragm rupture, diaphragm discontinuity was seen in seven (58%) cases, the collar sign in five (42%), the dependent viscera sign in four (33%), and transdiaphragmatic herniation of the right colon and fat in another. Two variants of the collar sign were apparent on high-quality sagittal and coronal reformations. The first, termed the 'hump sign', describes a rounded portion of liver herniating through the diaphragm forming a hump-shaped mass, and the second, termed the 'band sign,' is a linear lucency across the liver along the torn edges of the hemidiaphragm. The hump sign occurred in 10 (83%) patients and the band sign in four (33%). CONCLUSION: MDCT is very useful in the diagnosis of right hemidiaphragm injury caused by blunt trauma when sagittal and coronal reformatted images are obtained, and should allow more frequent preoperative diagnosis

  17. Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical audit

    International Nuclear Information System (INIS)

    Tack, Denis; Jahnen, Andreas; Kohler, Sarah; Harpes, Nico; Back, Carlo; Maertelaer, Viviane de; Gevenois, Pierre Alain

    2014-01-01

    To report short- and long-term effects of an audit process intended to optimise the radiation dose from multidetector row computed tomography (MDCT). A survey of radiation dose from all eight MDCT departments in the state of Luxembourg performed in 2007 served as baseline, and involved the most frequently imaged regions (head, sinus, cervical spine, thorax, abdomen, and lumbar spine). CT dose index volume (CTDIvol), dose-length product per acquisition (DLP/acq), and DLP per examination (DLP/exa) were recorded, and their mean, median, 25th and 75th percentiles compared. In 2008, an audit conducted in each department helped to optimise doses. In 2009 and 2010, two further surveys evaluated the audit's impact on the dose delivered. Between 2007 and 2009, DLP/exa significantly decreased by 32-69 % for all regions (P < 0.001) except the lumbar spine (5 %, P = 0.455). Between 2009 and 2010, DLP/exa significantly decreased by 13-18 % for sinus, cervical and lumbar spine (P ranging from 0.016 to less than 0.001). Between 2007 and 2010, DLP/exa significantly decreased for all regions (18-75 %, P < 0.001). Collective dose decreased by 30 % and the 75th percentile (diagnostic reference level, DRL) by 20-78 %. The audit process resulted in long-lasting dose reduction, with DRLs reduced by 20-78 %, mean DLP/examination by 18-75 %, and collective dose by 30 %. (orig.)

  18. Preoperative multidetector CT manifestations of perigastric lymph nodes in patients with early gastric cancer and pN0

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Jung Hyun; Yu, Jeong Sik; Chung, Jae Joon; Lim, Joo Hee; Cho, Eun Suk; Kim, Ki Whang [Dept. of Radiology, Yonsei University College of Medicine, Gangnam Severance Hospital, Seoul (Korea, Republic of)

    2013-11-15

    To find the determinant of lymph node (LN) manifestations on preoperative multidetector CT (MDCT) in early gastric cancer (EGC) patients with pN0. One hundred and eighty-six consecutive patients with pT1pN0, the largest perigastric LN on preoperative MDCT, were categorized into two groups according to 8 different parameters [short (SD) and long diameter (LD) 4/6/8 mm, average attenuation 100 Hounsfield unit, short-to-long diameter-ratio (SLR) 0.7], and correlated with the size, gross type, depth of invasion and microscopic type of their primary lesions by the chi-square test and multiple logistic regression analysis. When the primary lesion was larger than 3 cm, the LNs were larger in 4 parameters (SD or LD, 4/6 mm; p < 0.05); gross type IIb patients showed smaller LNs in 5 parameters (SD 4/6 mm, LD 4/6/8 mm; p < 0.05); and patients with microscopically-undifferentiated lesions showed larger LNs in SD 4 mm or LD 8 mm by the chi-square test and multiple logistic regression analysis. The depth of invasion showed no significant difference in LN size. No factors revealed significant difference in LN attenuation or SLR. Benign regional LN enlargement is more frequent in EGC patients with larger size primary lesions or lesion with poor microscopic differentiation. However, this condition is less frequent in gross type IIb patients.

  19. Multidetector CT and MRI of ostial atresia of the coronary sinus, associated collateral venous pathways and cardiac anomalies

    International Nuclear Information System (INIS)

    Shum, J.S.F.; Kim, S.M.; Choe, Y.H.

    2012-01-01

    Aim: To analyse the multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) findings in patients with atresia of the coronary sinus orifice (CSA). Materials and methods: MDCT findings of 15 consecutive adult patients with CSAs were retrospectively analysed. The patients underwent contrast-enhanced electrocardiography-gated MDCT (n = 13) or both CT and MRI (n = 2). Results: The mean size of the coronary sinus (CS) was 14.2 mm (range 5.5–24 mm) and 11 patients (73.3%) showed CS dilatation (diameter ≥12 mm). The mean length of the atretic CS segment was 2.9 mm (range 0–8 mm). Different forms of venous collateral pathways were observed in the CSA patients. Nine (60%) of the 15 CSA patients had communication between the right atrium (RA; n = 6) or LA (n = 5) and CS via intraseptal veins; six patients (40%) had persistent left superior caval veins; communications were also observed between the CS and RA (n = 4) or LA (n = 4); two patients had collateral venous pathways between dilated cardiac veins with RA; two patients had unroofing of the CS as outlet channels. Nine patients (60%) had cardiac anomalies: coronary artery fistula to the pulmonary artery (n = 6) or left ventricular base and CS (n = 1), atrial septal defects (n = 2), and a ventricular septal defect (n = 1). Conclusion: CSA patients have venous collateral pathways and a high incidence of associated cardiovascular anomalies such as coronary artery fistulae and atrial septal defects.

  20. Multidetector CT of pancreatic ductal adenocarcinoma: Effect of tube voltage and iodine load on tumour conspicuity and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Loizou, L.; Leidner, B.; Axelsson, E.; Fischer, M.A.; Grigoriadis, A.; Kartalis, N. [Karolinska Institutet, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Stockholm (Sweden); C1-46 Karolinska University Hospital Huddinge, Department of Radiology, Stockholm (Sweden); Albiin, N. [Karolinska Institutet, Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Stockholm (Sweden); Ersta Hospital, Department of Radiology, Stockholm (Sweden); Del Chiaro, M.; Segersvaerd, R. [Karolinska University Hospital Huddinge, Division of Surgery, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet and Center for Digestive Diseases, Stockholm (Sweden); Verbeke, C. [Karolinska Institutet and Karolinska University Hospital Huddinge, Division of Pathology, Department of Laboratory Medicine, Stockholm (Sweden); Sundin, A. [Uppsala University Hospital, Department of Surgical Sciences, Division of Radiology, Uppsala University and Department of Radiology, Uppsala (Sweden)

    2016-11-15

    To compare a low-tube-voltage with or without high-iodine-load multidetector CT (MDCT) protocol with a normal-tube-voltage, normal-iodine-load (standard) protocol in patients with pancreatic ductal adenocarcinoma (PDAC) with respect to tumour conspicuity and image quality. Thirty consecutive patients (mean age: 66 years, men/women: 14/16) preoperatively underwent triple-phase 64-channel MDCT examinations twice according to: (i) 120-kV standard protocol (PS; 0.75 g iodine (I)/kg body weight, n = 30) and (ii) 80-kV protocol A (PA; 0.75 g I/kg, n = 14) or protocol B (PB; 1 g I/kg, n = 16). Two independent readers evaluated tumour delineation and image quality blindly for all protocols. A third reader estimated the pancreas-to-tumour contrast-to-noise ratio (CNR). Statistical analysis was performed with the Chi-square test. Tumour delineation was significantly better in PB and PA compared with PS (P = 0.02). The evaluation of image quality was similar for the three protocols (all, P > 0.05). The highest CNR was observed with PB and was significantly better compared to PA (P = 0.02) and PS (P = 0.0002). In patients with PDAC, a low-tube-voltage, high-iodine-load protocol improves tumour delineation and CNR leading to higher tumour conspicuity compared to standard protocol MDCT. (orig.)

  1. Multidetector CT radiation dose optimisation in adults: short- and long-term effects of a clinical audit

    Energy Technology Data Exchange (ETDEWEB)

    Tack, Denis [EpiCURA Hospital, Clinique Louis Caty, Department of Radiology, Baudour (Belgium); Jahnen, Andreas; Kohler, Sarah [CRP Henri Tudor, Luxembourg (Luxembourg); Harpes, Nico; Back, Carlo [Ministry of Health, Department of Radiation Protection, Luxembourg (Luxembourg); Maertelaer, Viviane de [Universite libre de Bruxelles, Institut de Recherche Interdisciplinaire en Biologie Humaine et Moleculaire and SBIM, Statistical Unit, Brussels (Belgium); Gevenois, Pierre Alain [Hopital Erasme, Department of Radiology, Brussels (Belgium)

    2014-01-15

    To report short- and long-term effects of an audit process intended to optimise the radiation dose from multidetector row computed tomography (MDCT). A survey of radiation dose from all eight MDCT departments in the state of Luxembourg performed in 2007 served as baseline, and involved the most frequently imaged regions (head, sinus, cervical spine, thorax, abdomen, and lumbar spine). CT dose index volume (CTDIvol), dose-length product per acquisition (DLP/acq), and DLP per examination (DLP/exa) were recorded, and their mean, median, 25th and 75th percentiles compared. In 2008, an audit conducted in each department helped to optimise doses. In 2009 and 2010, two further surveys evaluated the audit's impact on the dose delivered. Between 2007 and 2009, DLP/exa significantly decreased by 32-69 % for all regions (P < 0.001) except the lumbar spine (5 %, P = 0.455). Between 2009 and 2010, DLP/exa significantly decreased by 13-18 % for sinus, cervical and lumbar spine (P ranging from 0.016 to less than 0.001). Between 2007 and 2010, DLP/exa significantly decreased for all regions (18-75 %, P < 0.001). Collective dose decreased by 30 % and the 75th percentile (diagnostic reference level, DRL) by 20-78 %. The audit process resulted in long-lasting dose reduction, with DRLs reduced by 20-78 %, mean DLP/examination by 18-75 %, and collective dose by 30 %. (orig.)

  2. Accuracy of hepatocellular carcinoma detection on multidetector CT in a transplant liver population with explant liver correlation

    International Nuclear Information System (INIS)

    Addley, H.C.; Griffin, N.; Shaw, A.S.; Mannelli, L.; Parker, R.A.; Aitken, S.; Wood, H.; Davies, S.; Alexander, G.J.; Lomas, D.J.

    2011-01-01

    Aim: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for hepatocellular carcinoma (HCC) in cirrhotic patients undergoing liver transplantation. Secondary aims were to examine the effect of radiologist experience and lesion size on diagnostic accuracy. Materials and methods: Thirty-nine patients (72% male with a mean age of 56.5 years) underwent liver transplantation following preoperative triple-phase MDCT examination of the liver. MDCT examinations were retrospectively independently reviewed by three radiologists for the presence and location of suspected HCCs, with the diagnostic confidence recorded using a five-point confidence scale. MDCT examinations were compared with explant specimens for histopathological correlation. Results: Histopathological results demonstrated 46 HCCs in 29 of the 39 patients. Analysis demonstrated a sensitivity of 65-75% and specificity of 47-88% for detection of HCC lesions. The sensitivity dropped to 48-57% for lesions of size ≤20 mm. As the diagnostic confidence increased, there was a further decrease in the sensitivity (4-26%). The radiologist with the greatest number of years experience was found to have a significantly higher accuracy of detection of HCC lesions compared with the least experienced radiologist. Conclusion: Larger lesion size of HCC and greater number of years experience of the radiologist resulted in significantly higher accuracy of HCC lesion detection. The overall sensitivity and specificity results for MDCT detection of HCC are comparable to previous helical CT imaging.

  3. Multidetector CT of pancreatic ductal adenocarcinoma: Effect of tube voltage and iodine load on tumour conspicuity and image quality

    International Nuclear Information System (INIS)

    Loizou, L.; Leidner, B.; Axelsson, E.; Fischer, M.A.; Grigoriadis, A.; Kartalis, N.; Albiin, N.; Del Chiaro, M.; Segersvaerd, R.; Verbeke, C.; Sundin, A.

    2016-01-01

    To compare a low-tube-voltage with or without high-iodine-load multidetector CT (MDCT) protocol with a normal-tube-voltage, normal-iodine-load (standard) protocol in patients with pancreatic ductal adenocarcinoma (PDAC) with respect to tumour conspicuity and image quality. Thirty consecutive patients (mean age: 66 years, men/women: 14/16) preoperatively underwent triple-phase 64-channel MDCT examinations twice according to: (i) 120-kV standard protocol (PS; 0.75 g iodine (I)/kg body weight, n = 30) and (ii) 80-kV protocol A (PA; 0.75 g I/kg, n = 14) or protocol B (PB; 1 g I/kg, n = 16). Two independent readers evaluated tumour delineation and image quality blindly for all protocols. A third reader estimated the pancreas-to-tumour contrast-to-noise ratio (CNR). Statistical analysis was performed with the Chi-square test. Tumour delineation was significantly better in PB and PA compared with PS (P = 0.02). The evaluation of image quality was similar for the three protocols (all, P > 0.05). The highest CNR was observed with PB and was significantly better compared to PA (P = 0.02) and PS (P = 0.0002). In patients with PDAC, a low-tube-voltage, high-iodine-load protocol improves tumour delineation and CNR leading to higher tumour conspicuity compared to standard protocol MDCT. (orig.)

  4. Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Jaeckle, T.; Stuber, G.; Hoffmann, M.H.K.; Jeltsch, M.; Schmitz, B.L.; Aschoff, A.J. [University Hospital of Ulm, Diagnostic and Interventional Radiology, Ulm (Germany)

    2008-07-15

    The purpose of this study was to evaluate the accuracy of multi-detector row helical CT (MDCT) for detection and localization of acute upper and lower gastrointestinal (GI) hemorrhage or intraperitoneal bleeding. Thirty-six consecutive patients with clinical signs of acute bleeding underwent biphasic (16- or 40-channel) MDCT. MDCT findings were correlated with endoscopy, angiography or surgery. Among the 36 patients evaluated, 26 were examined for GI bleeding and 10 for intraperitoneal hemorrhage. Confirmed sites of GI bleeding were the stomach (n = 5), duodenum (n = 5), small bowel (n = 6), large bowel (n = 8) and rectum (n = 2). The correct site of bleeding was identifiable on MDCT in 24/26 patients with GI bleeding. In 20 of these 24 patients, active CM extravasation was apparent during the exam. Among the ten patients with intraperitoneal hemorrhage, MDCT correctly identified the bleeding source in nine patients. Our findings suggest that fast and accurate localization of acute gastrointestinal and intraperitoneal bleeding is achievable on MDCT. (orig.)

  5. Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT

    International Nuclear Information System (INIS)

    Jaeckle, T.; Stuber, G.; Hoffmann, M.H.K.; Jeltsch, M.; Schmitz, B.L.; Aschoff, A.J.

    2008-01-01

    The purpose of this study was to evaluate the accuracy of multi-detector row helical CT (MDCT) for detection and localization of acute upper and lower gastrointestinal (GI) hemorrhage or intraperitoneal bleeding. Thirty-six consecutive patients with clinical signs of acute bleeding underwent biphasic (16- or 40-channel) MDCT. MDCT findings were correlated with endoscopy, angiography or surgery. Among the 36 patients evaluated, 26 were examined for GI bleeding and 10 for intraperitoneal hemorrhage. Confirmed sites of GI bleeding were the stomach (n = 5), duodenum (n = 5), small bowel (n = 6), large bowel (n = 8) and rectum (n = 2). The correct site of bleeding was identifiable on MDCT in 24/26 patients with GI bleeding. In 20 of these 24 patients, active CM extravasation was apparent during the exam. Among the ten patients with intraperitoneal hemorrhage, MDCT correctly identified the bleeding source in nine patients. Our findings suggest that fast and accurate localization of acute gastrointestinal and intraperitoneal bleeding is achievable on MDCT. (orig.)

  6. Cartilage lesions of the glenohumeral joint: diagnostic effectiveness of multidetector spiral CT arthrography and comparison with arthroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Lecouvet, Frederic E.; Dorzee, Benjamin; Berg, Bruno C. vande; Malghem, Jacques [Cliniques Universitaires St Luc, Universite Catholique de Louvain, Department of Radiology, Brussels (Belgium); Dubuc, Jean E. [Cliniques Universitaires St Luc, Universite Catholique de Louvain, Department of Orthopaedic Surgery, Brussels (Belgium); Jamart, Jacques [Mont Godinne University Hospital, Center of Biostatistics, Yvoir (Belgium)

    2007-07-15

    This study assessed the diagnostic effectiveness of multidetector spiral CT arthrography (MDCTa) in detecting hyaline cartilage abnormalities of the shoulder joint, with correlation to arthroscopy. Shoulder MDCTa images prospectively obtained in 22 consecutive patients (mean age, 50 years; age range, 23-74 years; 12 female, 10 male) were evaluated for glenohumeral cartilage lesions. Two musculoskeletal radiologists independently analysed the cartilage surfaces of the humeral head and of the glenoid fossa in nine anatomical surface areas. Observations of MDCTa were compared to arthroscopic findings. The sensitivity and specificity of MDCTa for grade 2 (substance loss <50%) or higher and grade 3 (substance loss {>=}50%) or higher cartilage lesions, the Spearman correlation coefficient between arthrographic and arthroscopic grading, and K statistics for assessing Intra and Interobserver reproducibility were determined. At MDCTa, sensitivities and specificities ranged between 80% and 94% for the detection of grade 2 or higher cartilage lesions, and between 88% and 98% for the detection of grade 3 or higher cartilage lesions. Spearman correlation coefficients between MDCTa and arthroscopic grading of articular surfaces ranged between 0.532 and 0.651. Interobserver agreement was moderate for grading all articular surfaces ({kappa} = 0.457), but substantial to almost perfect for detecting lesions with substance loss ({kappa}, 0.618-0.876). In conclusion, MDCTa is accurate for the study of cartilage surface in the entire shoulder joint. This technique may beneficially impact patient's management by means of selecting the proper treatment approach. (orig.)

  7. Multi-detector spiral CT study of the relationships between pulmonary ground-glass nodules and blood vessels

    International Nuclear Information System (INIS)

    Gao, Feng; Li, Ming; Ge, Xiaojun; Ren, Qingguo; Hua, Yanqing; Zheng, Xiangpeng; Chen, Yan; Lv, Fangzhen

    2013-01-01

    To investigate the relationships between pulmonary ground-glass nodules (GGN) and blood vessels and their diagnostic values in differentiating GGNs. Multi-detector spiral CT imaging of 108 GGNs was retrospectively reviewed. The spatial relationships between GGNs and supplying blood vessels were categorized into four types: I, vessels passing by GGNs; II, intact vessels passing through GGNs; III, distorted, dilated or tortuous vessels seen within GGNs; IV, more complicated vasculature other than described above. Relationship types were correlated to pathologic and/or clinical findings of GGNs. Of 108 GGNs, 10 were benign, 24 preinvasive nodules and 74 adenocarcinomas that were pathologically proven. Types I, II, III and IV vascular relationships were observed in 9, 58, 21 and 20 GGNs, respectively. Type II relationship was the dominating relationship for each GGN group, but significant differences were shown among them. Correlation analysis showed strong correlation between invasive adenocarcinoma and type III and IV relationships. Subgroup analysis indicated that type III was more commonly seen in IAC with comparison to type IV more likely seen in MIA. Different GGNs have different relationships with vessels. Understanding and recognising characteristic GGN-vessel relationships may help identify which GGNs are more likely to be malignant. (orig.)

  8. Image quality of high-resolution CT with 16-channel multidetector-row CT. Comparison between helical scan and conventional step-shoot scan

    International Nuclear Information System (INIS)

    Sumikawa, Hiromitsu; Johkoh, Takeshi; Koyama, Mitsuhiro

    2005-01-01

    The aim of this study was to evaluate the image quality of high-resolution CT (HRCT) reconstructed from volumetric data with 16-channel multidetector-row CT (MDCT). Eleven autopsy lungs that were diagnosed histopathologically were scanned by 16-channel MDCT with the step-and-shoot scan mode and three helical scan modes. Each helical mode had each size of focal spot, pitch, and time of gantry rotation. HRCT images were reconstructed from the volumetric data with each helical mode and axial sequence data. Two observers evaluated the image quality and noted the most appropriate diagnosis for each imaging. Visualization of abnormal structures with one helical mode was equal to those with axial mode, whereas those with the other two helical modes were inferior to those with axial mode (Wilcoxon signed rank test; p<0.0001). There was no significant difference in diagnostic efficacy between modes. The image quality of HRCT with appropriate helical mode is equal to that with axial mode and diagnostic efficacy is equal among all modes. These results may indicate that sufficient HRCT images can be obtained by only one helical scan without the addition of conventional axial scans. (author)

  9. CT findings of intraductal papillary neoplasm of the bile duct: Assessment with multiphase contrast-enhanced examination using multi-detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, H., E-mail: ogawa.hiroshi@h.mbox.nagoya-u.ac.jp [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Itoh, S. [Department of Radiology, Japanese Red Cross Nagoya Daiichi Hospital, Nagoya (Japan); Nagasaka, T. [Department of Medical Technology, Nagoya University School of Health Sciences, Nagoya (Japan); Suzuki, K. [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan); Ota, T. [Department of Radiology, Aichi Medical University Hospital, Nagakute Aichi (Japan); Naganawa, S. [Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya (Japan)

    2012-03-15

    Aim: To evaluate multi-detector computed tomography (MDCT) findings of intraductal papillary neoplasm of the bile duct (IPNB), a neoplasm that is considered to be the biliary counterpart of pancreatic intraductal papillary mucinous neoplasm. Materials and methods: Two radiologists retrospectively evaluated multiphase contrast-enhanced CT images with 0.5 or 1 mm collimation in 37 consecutive patients with resected IPNB diagnosed by a single pathologist. The CT findings were correlated with the pathological findings concerning invasion of the surrounding organs and vessels. Results: All patients showed bile duct dilatation. An intraductal mass was detected in 36 patients and the following findings were observed: extensive infiltration along the bile duct more than 20 mm (n = 32), compared with normal hepatic parenchyma, isodense or hyperdense during the late arterial phase (n = 31), not hyperdense during the portal-venous and delayed phases (n = 36), and intense enhancement rim at the base of the mass during the portal-venous or delayed phase (n = 27). Parenchymal invasion of the surrounding organs was seen in eight of 16 tumours showing irregular or bulging margins. Vascular invasion was false positive in four of eight tumours. Conclusions: IPNB exhibits relatively characteristic findings with multiphase contrast-enhanced examination using MDCT. A tendency to overestimate invasion of the surrounding organs and vessels was seen.

  10. 320-Multidetector row whole-head dynamic subtracted CT angiography and whole-brain CT perfusion before and after carotid artery stenting: Technical note

    International Nuclear Information System (INIS)

    San Millan Ruiz, Diego; Murphy, Kieran; Gailloud, Philippe

    2010-01-01

    Introduction: Multidetector CT (MDCT) is increasingly used for the investigation of neurovascular disorders, but restricted z-axis coverage (3.2 cm for 64-MDCT) currently limits perfusion to a small portion of the brain close to the circle of Willis, and precludes dynamic angiographic appreciation of the entire brain circulation. We illustrate the clinical potential of recently developed 320-MDCT extending the z-axis coverage to 16 cm in a patient with symptomatic carotid artery stenosis. Methods: In a 74-year-old patient presenting with critical symptomatic stenosis of the left CCA, pre- and post-carotid artery stenting whole-head subtracted dynamic MDCT angiography and perfusion were obtained in addition to CT angiography of the supra-aortic trunks. Both whole-head subtracted MDCT angiography and perfusion demonstrated delayed left ICA circulation, which normalized after carotid stenting. Discussion: 320-MDCT offers unprecedented z-axis coverage allowing for whole-brain perfusion and subtracted dynamic angiography of the entire intracranial circulation. These innovations can consolidate the role of MDCT as a first intention imaging technique for cerebrovascular disorders, in particular for the acute management of stroke.

  11. Role of multidetector abdominal CT in the evaluation of abnormalities in polyarteritis nodosa

    International Nuclear Information System (INIS)

    Singhal, M.; Gupta, P.; Sharma, A.; Lal, A.; Rathi, M.; Khandelwal, N.

    2016-01-01

    Aim: To identify arterial and end-organ abnormalities on abdominal computed tomography (CT) in patients with polyarteritis nodosa (PAN). Materials and methods: A prospective study comprising 27 consecutive patients with PAN was conducted from 2007 to 2013. Departmental ethics committee approval was obtained. All patients underwent contrast-enhanced CT comprising an arterial and a portal venous phase. Images were assessed for arterial irregularity, aneurysms, stenosis, and occlusion. End-organ changes, including infarcts, haematoma, and bowel involvement, were also recorded. Results: A positive CT was recorded in 15 patients including eight females. The mean age was 32 years. The most common abnormalities were aneurysms seen in 12 patients. The renal artery was the most common site of aneurysms (n=9). The hepatic (n=3), superior mesenteric (n=3) and splenic arteries (n=1) were also involved. Contour irregularity was noted in four patients involving the hepatic, splenic, and superior mesenteric arteries. Stenosis/occlusion was also noted in seven patients. The most common end-organ abnormality was infarct (n=9), followed by bowel wall thickening (n=3), and perinephric haematoma (n=2). Conclusion: A combination of arterial and end-organ abnormalities on abdominal CT enables an accurate diagnosis of PAN in occult cases and may obviate the need for angiography and, sometimes, biopsy. - Highlights: • A combination of findings on CT allows a diagnosis of PAN. • Specific findings include arterial and end organ abnormalities. • The most common abnormalities on CTA and CT are aneurysms and infarcts.

  12. Detection of intracranial aneurysms using three-dimensional multidetector-row CT angiography: Is bone subtraction necessary?

    International Nuclear Information System (INIS)

    Hwang, Seung Bae; Kwak, Hyo Sung; Han, Young Min; Chung, Gyung Ho

    2011-01-01

    Purpose: The aim of this study was to evaluate the usefulness of three-dimensional CT angiography (3D CTA) with bone subtraction in a comparison with 3D CTA without bone subtraction for the detection of intracranial aneurysms. Materials and methods: Among 337 consecutive patients who had intracranial aneurysms detected on 3D CTA, 170 patients who underwent digital subtraction angiography (DSA) were included in the study. CTA was performed with a 16-slice multidetector-row CT (MDCT) scanner. We created the 3D reconstruction images with and without bone subtraction by using the volume rendering technique. Three neuroradiologists in a blinded fashion interpreted both 3D CTA images with and without bone subtraction. The diagnostic accuracy of both techniques was evaluated using the alternative free-response receiver operating characteristic (ROC) analysis. The sensitivity and positive predictive value were also evaluated. Results: A total of 200 aneurysms (size: 2-23 mm) were detected in 170 patients. The area under the receiver operating characteristic curve (Az) for 3D CTA with bone subtraction (mean, Az = 0.933) was significantly higher than that for 3D CTA without bone subtraction (mean, Az = 0.879) for all observers (P < 0.05). The sensitivity of 3D CTA with bone subtraction for three observers was 90.0, 92.0 and 92.5%, respectively, while the sensitivity of 3D CTA without bone subtraction was 83.5, 83.5 and 87.5%, respectively. No significant difference in positive predictive value was observed between the two modalities. Conclusions: 3D CTA with bone subtraction showed significantly higher diagnostic accuracy for the detection of intracranial aneurysms as compared to 3D CTA without bone subtraction.

  13. Clinical applications of the superior epigastric artery perforator (SEAP) flap: anatomical studies and preoperative perforator mapping with multidetector CT.

    Science.gov (United States)

    Hamdi, Moustapha; Van Landuyt, Koenraad; Ulens, Sara; Van Hedent, Eddy; Roche, Nathalie; Monstrey, Stan

    2009-09-01

    Pedicled superior epigastric artery perforator (SEAP) flaps can be raised to cover challenging thoracic defects. We present an anatomical study based on multidetector computerized tomography (MDCT) scan findings of the SEA perforators in addition to the first reported clinical series of SEAP flaps in anterior chest wall reconstruction. (a) In the CT scan study, images of a group of 20 patients who underwent MDCT scan analysis were used to visualise bilaterally the location of musculocutaneous SEAP. X- and Y-axes were used as landmarks to localise the perforators. The X-axis is a horizontal line at the junction of sternum and xyphoid (JCX) and the Y-axis is at the midline. (b) In the clinical study, seven pedicled SEAP flaps were performed in another group of patients. MDCT images revealed totally 157 perforators with a mean of 7.85 perforators per patient. The dominant perforators (137 perforators) were mainly localised in an area between 1.5 and 6.5 cm from the X-axis on both sides and between 3 and 16 cm below the Y-axis. The calibre of these dominant perforators was judged as 'good' to 'very good' in 82.5% of the cases. The average dimension of the flap was 21.7x6.7 cm. All flaps were based on one perforator. Mean harvesting time was 110 min. There were no flap losses. Minor tip necrosis occurred in two flaps. One of them was treated with excision and primary closure. Our clinical experience indicates that the SEAP flap provides a novel and useful approach for reconstruction of anterior chest wall defects. CT-based imaging allows for anatomical assessment of the perforators of the superior epigastric artery (SEA).

  14. Evaluation of peripheral artery stent with 64-slice multi-detector row CT angiography: Prospective comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Li Xiaoming; Li Yuhua; Tian Jianming; Xiao Yi; Lu Jianping; Jing Zaiping; Sheng Jing; Edwin, Angela; Wu Fanghong

    2010-01-01

    Purpose: To assess the accuracy of 64-slice multi-detector row computed tomography (MDCT) angiography in the evaluation of peripheral artery in-stent or peristent restenosis, with conventional digital subtraction angiography (DSA) as the reference standard. Materials and methods: Forty-one patients (30 men, 11 women; mean age, 69.8 ± 9.2 years) with symptomatic peripheral arterial occlusive disease after peripheral artery stenting (81 stented lesions) underwent both conventional DSA and 64-slice MDCT angiography. Each stent was classified as evaluable or unevaluable, and every stent was divided into three segments (proximal stent, stent body, and distal stent), resulting in 243 segments. For evaluation, stenosis was graded as follows: 1, none or slight stenosis (<25%); 2, mild stenosis (25-49%); 3, moderate stenosis (50-74%); 4, severe stenosis or total occlusion (≥75%). Two readers evaluated all CT angiograms with regard to narrowing of in-stent or peristent restenosis by consensus. Results were compared with findings of the DSA. Results: Of 81 stents, 62 (76.5%) were determined to be assessable. The metal artifact of the gold marker and motion artifact increased uninterpretability of the images of stents. Overall, 24 of 28 in-stent restenosis and 38 of 53 persistent restenosis were correctly detected by MDCT (85.7% and 71.7% sensitivity). In evaluable stents, 21 of 22 in-stent restenoses and 27 of 28 persistent restenosis were correctly detected (95.4% and 96.4% sensitivity). Additionally, as the grade of stenosis increases, the mean level of CT values in the stent lumina decreases linearly accordingly. Conclusion: 64-Slice MDCT has a high accuracy for the detection of significant in-stent or peristent restenosis of assessable stents in patients with peripheral artery stent implantation and therefore can be considered as a valuable noninvasive technique for stent surveillance.

  15. Computer-assisted lung nodule volumetry from multi-detector row CT: Influence of image reconstruction parameters

    International Nuclear Information System (INIS)

    Honda, Osamu; Sumikawa, Hiromitsu; Johkoh, Takeshi; Tomiyama, Noriyuki; Mihara, Naoki; Inoue, Atsuo; Tsubamoto, Mitsuko; Natsag, Javzandulam; Hamada, Seiki; Nakamura, Hironobu

    2007-01-01

    Purpose: To investigate differences in volumetric measurement of pulmonary nodules caused by changing the reconstruction parameters for multi-detector row CT. Materials and methods: Thirty-nine pulmonary nodules less than 2 cm in diameter were examined by multi-slice CT. All nodules were solid, and located in the peripheral part of the lungs. The resultant 48 parameters images were reconstructed by changing slice thickness (1.25, 2.5, 3.75, or 5 mm), field of view (FOV: 10, 20, or 30 cm), algorithm (high-spatial frequency algorithm or low-spatial frequency algorithm) and reconstruction interval (reconstruction with 50% overlapping of the reconstructed slices or non-overlapping reconstruction). Volumetric measurements were calculated using commercially available software. The differences between nodule volumes were analyzed by the Kruskal-Wallis test and the Wilcoxon Signed-Ranks test. Results: The diameter of the nodules was 8.7 ± 2.7 mm on average, ranging from 4.3 to 16.4 mm. Pulmonary nodule volume did not change significantly with changes in slice thickness or FOV (p > 0.05), but was significantly larger with the high-spatial frequency algorithm than the low-spatial frequency algorithm (p < 0.05), except for one reconstruction parameter. The volumes determined by non-overlapping reconstruction were significantly larger than those of overlapping reconstruction (p < 0.05), except for a 1.25 mm thickness with 10 cm FOV with the high-spatial frequency algorithm, and 5 mm thickness. The maximum difference in measured volume was 16% on average between the 1.25 mm slice thickness/10 cm FOV/high-spatial frequency algorithm parameters and overlapping reconstruction. Conclusion: Volumetric measurements of pulmonary nodules differ with changes in the reconstruction parameters, with a tendency toward larger volumes in high-spatial frequency algorithm and non-overlapping reconstruction compared to the low-spatial frequency algorithm and overlapping reconstruction

  16. Hereditary haemorrhagic telangiectasia: study of hepatic vascular alterations with multi-detector row helical CT and reconstruction programs

    International Nuclear Information System (INIS)

    Memeo, Maurizio; Stabile Ianora, Amato Antonio; Scaldapane, Arnaldo; Rotondo, Antonio; Angelelli, Giuseppe; Suppressa, Patrizia; Cirulli, Anna; Sabba', Carlo

    2005-01-01

    Purpose: To evaluate hepatic alterations in patients affected by Hereditary Haemorrhagic Telangiectasia (HHT) by using multidetector row helical CT (MDCT) and new reconstruction programs. Materials and methods: An MDCT multiphasic study of the liver was performed in 105 consecutive patients: 89 considered to be affected by HHT and 16 with suspicion of disease alone. The scan delay was determined by using a test bolus of contrast material. The CT examination was performed with a triphasic technique (double arterial phase and portal venous phase). multiplanar and angiographic reconstructions were then obtained, and the images checked for the presence of shunts, hepatic perfusion disorders, vascular lesions (telangiectasis and large confluent vascular masses), indirect signs of portal hypertension, and anatomical vascular variants. Results: Hepatic vascular alterations were found in 78/105 cases (67/89) patients affected by HHT and 11/16 patients with clinical suspicion alone). Therefore HHT diagnosis was excluded in 5 patients. 78/100 (78%) patients with HHT had intrahepatic vascular alterations: arterioportal shunts in 40/78 (51.2%) arteriosystemic shunts in 16/78 (20.5%) and both shunt types in 22/78 (28.3%). Intraparenchymal perfusion disorders were found in 46/78 (58.9%) patients. Telangiectasis were recognised in 50/78 (64.1%) patients. Large confluent vascular masses (LCVMs) were identified in 20/78 (25.6%) patients. indirect signs of portal hypertension were found in 46/78 (58.9%) cases. Variant hepatic arterial anatomy was present in 38/100 cases (38%). Conclusions: Multiphasic MDCT and the new reconstruction programs enable the identification and characterisation of the complex vascular alterations typical of HHT [it

  17. Value of oral effervescent powder administration for multidetector CT evaluation of esophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ringe, Kristina I., E-mail: ringe.kristina@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Meyer, Simone, E-mail: Meyer.simone.rad@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Ringe, Bastian P., E-mail: Ringe.bastian@mh-hannover.de [Department of General, Visceral and Transplantation Surgery, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Winkler, Michael, E-mail: Winkler.michael@mh-hannover.de [Department of General, Visceral and Transplantation Surgery, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Wacker, Frank, E-mail: Wacker.frank@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Raatschen, Hans-Juergen, E-mail: Raatschen.hans-juergen@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany)

    2015-02-15

    Highlights: • Oral effervescent powder improves esophageal distension and wall assessment at CT. • This technique improves detection and T staging of esophageal cancer at CT. • It can be easily adopted in clinical routine in patients with esophageal pathology. - Abstract: Purpose: To assess the value of oral effervescent powder (EP) for evaluation of esophageal distension, and for detection and staging of esophageal cancer with contrast-enhanced CT. Materials and methods: 84 patients without esophageal pathology and 52 patients with histological confirmed diagnosis of esophageal cancer were included in this prospective IRB-approved study. Half of the patients in both groups received EP prior to CT. Esophageal distension was assessed by planimetry of the inner (IA) and outer area (OA). Two blinded readers evaluated the datasets separately with regard to diagnosis of esophageal cancer (yes/no) and staging (T0-T4), if applicable. Distension results were compared (t-Test). In patients with cancer sensitivity, specificity, NPV and PPV were calculated. CT staging results were compared to histopathology (Cohen-k). Results: IA and IA/OA were significantly larger after EP as compared to the group without EP (p < 0.05). Sensitivity, specificity, NPV and PPV for cancer detection cancer were as follows: 78%/78%, 98%/98%, 95%/95%, 87%/87% with EP; 60%/68%, 98%/98%, 94%/94%, 80%/83% without EP. Staging with EP was good (k = 0.84/0.67) and moderate without EP (k = 0.58/0.59). Conclusions: Administration of EP prior to CT results in good distension of the esophagus, and improves detection and staging of esophageal cancer, as compared to control studies without EP.

  18. Diagnosis of acute flank pain caused by ureteral stones: value of combined direct and indirect signs on IVU and unenhanced helical CT

    International Nuclear Information System (INIS)

    Wang, Li-Jen; Wong, Yon-Cheong; Ng, Chip-Jin; Chen, Jih-Chang; Chiu, Te-Fa

    2004-01-01

    The aim of this study was to assess the usefulness of combined direct and indirect signs on intravenous urography (IVU) and unenhanced helical computed tomography (UHCT) for the diagnosis of ureteral stones in emergency patients with acute flank pain. During an 8-month period, 82 emergency patients with acute flank pain undergoing IVU and UHCT with sufficient clinical follow-up formed the study group. The presence or absence of direct sign (visualization of ureteral stones) and indirect signs on IVU and UHCT was recorded. The diagnostic accuracy of each direct/indirect sign and their combination for the diagnosis of ureteral stones on IVU and UHCT were analyzed and compared. Of the 82 patients, 66 had ureteral stones, four had passed urinary stones prior to imaging and 12 had other diseases. The diagnostic accuracies of direct signs on IVU and UHCT for the diagnosis of ureteral stones were 79.3 and 98.8%, respectively, which was more accurate than that of any single indirect sign on IVU and UHCT. However, the diagnostic accuracy of ureteral stones by IVU increased to 90.2% when using diagnostic criteria requiring the presence of a direct sign or at least three indirect signs, and by UHCT, it increased to 100% when using diagnostic criteria requiring the presence of a direct sign with at least one indirect sign. Therefore, for emergency patients with acute flank pain, the use of the above combinations of direct/indirect signs is useful as the diagnostic criterion for ureteral stones. (orig.)

  19. Chronic thromboembolic pulmonary hypertension (CTEPH). Potential role of multidetector-row CT (MD-CT) and MR imaging in the diagnosis and differential diagnosis of the disease

    Energy Technology Data Exchange (ETDEWEB)

    Wirth, G.; Brueggemann, K.; Bostel, T.; Dueber, C.; Kreitner, K.F. [Universitaetsmedizin Mainz (Germany). Dept. of Radiology; Mayer, E. [Kerckhoff Hospital, Bad Nauheim (Germany). Dept. of Thoracic Surgery

    2014-08-15

    Chronic thromboembolic pulmonary hypertension (CTEPH) can be defined as pulmonary hypertension (resting mean pulmonary arterial pressure of 25 mm Hg or more determined at right heart catheterization) with persistent pulmonary perfusion defects. It is a rare, but underdiagnosed disease with estimated incidences ranging from 0.5% to 3.8% of patients after an acute pulmonary embolism (PE), and in up to 10% of those with a history of recurrent PE. CTEPH is the only form of pulmonary hypertension that can be surgically treated leading to normalization of pulmonary hemodynamics and exercise capacity in the vast majority of patients. The challenges for imaging in patients with suspected CTEPH are fourfold: the imaging modality should have a high diagnostic accuracy with regard to the presence of CTEPH and allow for differential diagnosis. It should enable detection of patients suitable for PEA with great certainty, and allow for quantification of PH by measuring pulmonary hemodynamics (mPAP and PVR), and finally, it can be used for therapy monitoring. This overview tries to elucidate the potential role of ECG-gated multidetector CT pulmonary angiography (MD-CTPA) and MR imaging, and summarizes the most important results that have been achieved so far. Generally speaking, ECG-gated MD-CTPA is superior to MR in the assessment of parenchymal and vascular pathologies of the lung, and allows for the assessment of cardiac structures. The implementation of iodine maps as a surrogate for lung perfusion enables functional assessment of lung perfusion by CT. MR imaging is the reference standard for the assessment of right heart function and lung perfusion, the latter delineating typical wedge-shaped perfusion defects in patients with CTEPH. New developments show that with MR techniques, an estimation of hemodynamic parameters like mean pulmonary arterial pressure and pulmonary vascular resistance will be possible. CT and MR imaging should be considered as complementary

  20. Multi-detector row helical CT of the liver. Quantitative assessment of iodine concentration of intravenous contrast material on multiphasic CT. A prospective randomized study

    International Nuclear Information System (INIS)

    Tsurusaki, Masakatsu; Sugimoto, Koji; Fujii, Masahiko; Sugimura, Kazuro

    2004-01-01

    The purpose of this study was to assess the quantitative effects of contrast material concentration on hepatic parenchymal and vascular enhancement in multiphasic computed tomography (CT), using multi-detector row helical CT. We designed a prospective randomized study to test two different concentrations of contrast material on five phasic scans of the liver. One hundred patients were randomly assigned to two groups: an iodine concentration of 300 mg/mL in group A and 370 mg/mL in group B. All patients received a fixed volume of 100 mL at a 4 mL/sec injection rate. Enhancement values for the hepatic parenchyma and aorta at three levels (upper, middle, and lower level of the liver), and values for portal and hepatic veins were statistically compared between the two groups. Hepatic parenchymal enhancement values at all levels of the liver in portal phase (PP) and equilibrium phase (EP) were significantly higher in group B than in group A (p<0.01). Aortic enhancement values at two levels of the liver (middle and lower) in early hepatic arterial phase (EAP) were significantly higher in group B than in group A (p<0.05), however, there was no significant difference between groups A and B in aortic enhancement during the delayed hepatic arterial phase (DAP). Portal and hepatic venous enhancement values in PP and EP were significantly higher in group B than in group A (p<0.01). On multiphasic dynamic CT, the use of a higher iodine concentration of contrast material results in higher hepatic parenchymal enhancement and aortic enhancement, as well as higher portal and hepatic venous enhancement. (author)

  1. First experience with multidetector-CT for the diagnosis of coronary atherosclerosis

    International Nuclear Information System (INIS)

    Becker, C.R.; Hong, C.; Schoepf, U.J.; Reiser, M.F.; Knez, A.; Leber, A.; Treede, H.; Wildhirt, S.; Ohnesorge, B.; Flohr, T.

    2000-01-01

    Purpose: Multirow-detector-spiral-CT (MSCT) allows for 250 ms effective exposure time. The purpose of this study was to demonstrate the possibilities and limitations of this CT technology for non enhanced and contrast enhanced investigation of the coronary arteries. Methods: Investigation of the coronary arteries without contrast medium for quantification of coronary calcifications was performed in an obese patient (140 kg) with MSCT and electron beam CT (EBCT). In 56 patients contrast enhanced CT angiography of the coronary arteries was performed to determine image quality depending on the heart rate. Results: In the obese patient superior image quality could be achieved with MSCT allowing for reliable quantification of coronary calcifications. With MSCT angiography of the coronary arteries good image quality was achieved in patients with a heart rate of 59±8 beats per minute. Conclusion: Even if there are limitations in patients with higher heart rates with an effective exposure time of 250 ms MSCT has clear advantage of image quality in the assessment of non enhanced and contrast enhanced coronary arteries. (orig.) [de

  2. Neutron CT with a multi-detector system leading to drastical reduction of the measuring time

    International Nuclear Information System (INIS)

    Hehn, G.; Pfister, G.; Schatz, A.; Goebel, J.; Kofler, R.

    1993-09-01

    By means of numerical simulation methods and their verification with measurements it could be shown that such a detector system can be realized for a line beam and 1-2 detectors per cm. With the maximum available beam width of the fast neutron field at the FRM approximately 20 detectors can be used leading to a reduction of the measuring time to 0,5 - 1 hour. A multi detector system for a line beam of thermal neutrons was constructed, tested and used for CT-measurements. This detector system for the measurement of thinner layers with better spatial resolution could be realized. The electronic discrimination between neutrons and gamma rays has been improved. This discrimination was used in all CT-measurements to get transmission values of both kinds of radiation and to reconstruct to complementary CT-images. The use of a polyenergetic radiation causes spectral shifts in the transmission spectrum leading to artifacts in the reconstructed CT-image. The transmission values must be spectral corrected before image reconstruction, because the image artifacts complicate the image evaluation or make it impossible. A new energy selective procedure for the online spectral correction was developed. This method is based on the concept to measure additionally to the integral transmission value his pulse height spectrum and to do the correction depending on the changes in this pulse height spectrum. (orig./HP) [de

  3. Usefulness of the Negative Multidetector CT Angiography in Patients with Suspected Pulmonary Embolism

    International Nuclear Information System (INIS)

    Holguin Holguin, Alfonso Jose; Lombana, Milton; Collazos, Giovanny; Bravo, Hector; Abella Calle, Jose

    2012-01-01

    Objective: The aim of the study is to evaluate alternative findings in pulmonary CT angiography using MDCT reported as negative in patients with suspected pulmonary embolism. Material and method: Cross sectional study with 178 patients. We recognized other findings reported in pulmonary CT angiography using MDCT whose result was negative. Subsequently these findings were classified into six different categories of clinical relevance and their association with clinical scenario was analyzed. Results: from November 2004 to June 2007 we requested 231 pulmonary CT angiography using MDCT in patients with suspected pulmonary embolism. 217 patients were included in the final analysis. Of these, 39 (185) were positive for pulmonary embolism. The 178 remaining negative studies, 8.43% were normal, 53.37% were classified as category A, 20.79% category B, 14.04% category C; category D 1.12% and 2.25% were not interpretable. The most frequent diagnoses were pneumonia, interstitial lung disease and cardiogenic pulmonary edema. It was less likely to find a normal report whether the study was requested in the hospital department in emergency patients (OR = 0.38 95% 0.16 to 0.88, p = 0.0007). No differences were found in other categories or between patients younger or older than 65 years (p = 0.436). Conclusion: Pulmonary CT angiography as first line imaging tool in patients with suspected pulmonary embolism is useful, offering alternative diagnoses in hospitalized and emergency room patients, regardless of their age and clinical findings.

  4. Multidetector CT angiography in the diagnosis and classification of carotid–cavernous fistula

    International Nuclear Information System (INIS)

    Lee, J.Y.; Jung, C.; Ihn, Y.K.; Kim, D.J.; Seong, S.O.; Kwon, B.J.

    2016-01-01

    Aim: To evaluate the performance of multidetector computed tomography angiography (MDCTA) in identifying and classifying carotid–cavernous fistulas (CCFs). Materials and methods: The neuro-interventional database was searched for patients with CCFs at four different institutions and for normal controls at one of the four institutions. Thirty-four patients were divided into the case group (direct type, n=8; indirect type, n=8) and the control group (n=18). Two readers retrospectively evaluated thin-section CTA images for the presence and laterality of four findings: (1) engorged ophthalmic vein, (2) engorged cavernous sinus, (3) similar enhancement of the cavernous sinus (CS) and internal carotid artery (ICA), and (4) greater enhancement of the CS than the transverse sinus (TS). Dehiscent ICA for the direct type was assessed only in the case group. Sensitivity, specificity, and inter-reader agreement were determined. Attenuation differences between the ICA and CS and between the CS and TS were compared across groups. Results: The sensitivity/specificity for two engorgement and two enhancement findings were 81%/100%, 88%/94%, 100%/100%, and 88%/100%, respectively, for Reader 1, and 75%/100%, 75%/100%, 88%/100%, and 88%/100%, respectively, for Reader 2. Agreement between readers was excellent for all findings (κ>0.80). Dehiscent ICA identified the direct type with a sensitivity/specificity of 100%/75% for Reader 1 and 100%/88% for Reader 2 (κ=0.871). In the case group, the difference between ICA and CS attenuation values was significantly lower (180.1±76.6 versus 7.5±23.7; ⤳<0.001) and that between CS and TS were higher (–31.2±69 versus 102.6±59.3; ⤳<0.001). The area under the curve for the latter values was 0.95. Conclusion: The engorgement and enhancement categories in MDCTA may perform comparably in identifying CCFs and measurements of vessel attenuation differences may be of high diagnostic value. Dehiscent ICA can greatly aid in identifying the

  5. Normal renal arterial anatomy assessed by multidetector CT angiography: are there differences between men and women?

    Science.gov (United States)

    Turba, Ulku Cenk; Uflacker, Renan; Bozlar, Ugur; Hagspiel, Klaus D

    2009-03-01

    The purpose of this study was to determine renal arterial anatomy and gender differences in adults without renovascular disease using multidetector computed tomography angiography (MDCTA). MDCTA datasets of 399 patients were retrospectively reviewed. Measurements of the aortorenal diameters, the angulation of the renal ostia and pedicles as well as the distance between the origins of the renal arteries were measured. Differences in measurements between genders were tested for statistical significance using analysis of variance (ANOVA) and Pearson's Chi-Square tests. A total of 798 renal arteries were available for analysis in 207 female (mean age = 52.91 years) and 192 male patients (mean age = 53.04 years). Female patients were found to have smaller aortae (at the level of the right renal ostium) and bilateral renal arteries than males (mean aortic diameter M/F = 18.33/15.89 mm, mean right renal artery ostial diameter M/F = 5.06/4.59 mm, mean left ostial renal diameter M/F = 5.14/4.66 mm) (p renal ostia level in relation to the vertebrae and the majority of renal arteries originated at the L1 and L2 levels. The longitudinal distance between right and left renal artery ostia ranged from 0 to 32 mm (mean = 4,6 mm, median = 5mm). The mean anteroposterior orientation of the right renal ostia was M/F = 29.45 degrees/28.20 degrees , and M/F = -7.96 degrees/-11.14 degrees for left renal artery ostia. The mean anteroposterior orientation of the right renal pedicle was M/F = 41.37 degrees/44.34 degrees and M/F = 42.31 degrees/43.95 degrees for the left pedicle. There are some differences in normal renal arterial anatomy between genders. Normal renal arterial information is useful not only for planning and performing of endovascular and laparoscopic urologic procedures, but also for medical device development. Copyright 2009 Wiley-Liss, Inc.

  6. Integrated cardio-thoracic imaging with ECG-Gated 64-slice multidetector-row CT: initial findings in 133 patients

    International Nuclear Information System (INIS)

    Salem, Randa; Remy-Jardin, Martine; Delhaye, Damien; Khalil, Chadi; Teisseire, Antoine; Remy, Jacques; Delannoy-Deken, Valerie; Duhamel, Alain

    2006-01-01

    The purpose of this study was to investigate the possibility of assessing the underlying respiratory disease as well as cardiac function during ECG-gated CT angiography of the chest with 64-slice multidetector-row CT (MDCT). One hundred thirty-three consecutive patients in sinus rhythm with known or suspected ventricular dysfunction underwent an ECG-gated CT angiographic examination of the chest without β-blockers using the following parameters: (1) collimation: 32 x 0.6 mm with z-flying focal spot for the acquisition of 64 overlapping 0.6-mm slices (Sensation 64; Siemens); rotation time: 0.33 s; pitch: 0.3; 120 kV; 200 mAs; ECG-controlled dose modulation (ECG-pulsing) and (2) 120 ml of a 35% contrast agent. Data were reconstructed: (1) to evaluate the underlying respiratory disease (1-mm thick lung and mediastinal scans reconstructed at 55% of the R-R interval; i.e., ''morphologic scans'') and (2) to determine right (RVEF) and left (LVEF) ventricular ejection fractions (short-axis systolic and diastolic images; Argus software; i.e., ''functional scans''). The mean heart rate was 73 bpm (range: 42-120) and the mean scan time was 18.11±2.67 s (range: 10-27). A total of 123 examinations (92%) had both lung and mediastinal images rated as diagnostic scans, whereas 10 examinations (8%) had non-diagnostic images altered by the presence of respiratory-motion artifacts (n=4) or cyclic artifacts related to the use of a pitch value of 0.3 in patients with a very low heart rate during data acquisition (n=6). Assessment of right and left ventricular function was achievable in 124 patients (93%, 95% CI: 88-97%). For these 124 examinations, the mean RVEF was 46.10% (±9.5; range: 20-72) and the mean LVEF was 58.23% (±10.88; range: 20-83). In the remaining nine patients, an imprecise segmentation of the right and left ventricular cavities was considered as a limiting factor for precise calculation of end-systolic and end-diastolic ventricular volumes. The mean (±SD) DLP

  7. Clinical application of multi-detector CT-guided percutaneous coaxial biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Jia Ningyang; Liu Shiyuan; Zhang Dianbo; Xiao Xiangsheng; Li Wentao; Li Chenzhou

    2008-01-01

    Objective: To evaluate the clinical application of multi-slice CT-guided percutaneous transthoracic lung coaxial-biopsy for pulmonary lesions. Methods: 152 times of 143 patients were performed with percutaneous transthoracic coaxial biopsy under multiple-slice CT-guidance. Analysis was carried out to investigate the diagnostic accuracy and the relationship between the size of the lesions for coaxial biopsy, together with the complications. Results: The diagnostic accuracy was 94.9% with specificity of 100%, including malignant tumors 116 cases (squamous cell cancer 48 cases, adenocarcinoma 34, small cell undifferentiated carcinoma 6, large cell carcinoma 4, bronchial alveolar carcinoma 8, metastatic carcinoma 16) and 19 cases of benign ones(TB 7 cases, inflammatory pseudotumor 9, hematoma 1, lung abscess 1). The size of lesion had a significant influence on the diagnostic accuracy. Conclusions: Percutaneous transthoracic coaxial lung biopsy is a safety method, possessing a high diagnostic accuracy. (authors)

  8. Active hemorrhage and vascular injuries in splenic trauma: utility of the arterial phase in multidetector CT.

    Science.gov (United States)

    Uyeda, Jennifer W; LeBedis, Christina A; Penn, David R; Soto, Jorge A; Anderson, Stephan W

    2014-01-01

    To determine whether the addition of arterial phase computed tomography (CT) to the standard combination of portal venous and delayed phase imaging increases sensitivity in the diagnosis of active hemorrhage and/or contained vascular injuries in patients with splenic trauma. The institutional review board approved this HIPAA-compliant retrospective study; the requirement to obtain informed consent was waived. The study included all patients aged 15 years and older who sustained a splenic injury from blunt or penetrating trauma and who underwent CT in the arterial and portal venous phases of image acquisition during a 74-month period (September 2005 to November 2011). CT scans were reviewed by three radiologists, and a consensus interpretation was made to classify the splenic injuries according to the American Association for the Surgery of Trauma splenic injury scale. One radiologist independently recorded the presence of contained vascular injuries or active hemorrhage and the phase or phases at which these lesions were seen. Clinical outcome was assessed by reviewing medical records. The relationship between imaging findings and clinical management was assessed with the Fisher exact test. One hundred forty-seven patients met the inclusion criteria; 32 patients (22%) had active hemorrhage and 22 (15%) had several contained vascular injuries. In 13 of the 22 patients with contained injuries, the vascular lesion was visualized only at the arterial phase of image acquisition; the other nine contained vascular injuries were seen at all phases. Surgery or embolization was performed in 11 of the 22 patients with contained vascular injury. The arterial phase of image acquisition improves detection of traumatic contained splenic vascular injuries and should be considered to optimize detection of splenic injuries in trauma with CT. ©RSNA, 2013.

  9. The effects of misinterpretation of an artefact on multidetector row CT scans in children

    Energy Technology Data Exchange (ETDEWEB)

    Du Plessis, Anne-Marie; Theron, Salomine; Andronikou, Savvas [University of Stellenbosch, Radiology Department, Tygerberg Hospital, Cape Town (South Africa)

    2009-02-15

    Artefacts reflect problems with radiographic technique rather than true pathology. These may be misinterpreted as pathology with serious consequences. An artefact caused such problems in one paediatric imaging department. To determine the incidence, and consequences of misinterpretation, of a CT artefact in a paediatric imaging department. A retrospective review of images and reports of paediatric CT scans over a set period with a known artefact was performed. Reports were correlated with reviewers' evaluation of the presence of artefact and reviewed for correct identification of artefact, misinterpretation as pathology, and action taken as a result. A total of 74 CT scans had been performed over the study period and an artefact detected by reviewers on 32 (43%). Six (18.75%) of these were misinterpreted as pathology, of which three (9.4%) were reported as tuberculous granulomas, two (6.2%) as haemorrhages and one (3.1%) as an unknown hyperdensity. Two patients (6.2%) had subsequent MRI studies performed, and treatment for tuberculosis was continued in one patient (3.1%). No initial report identified the artefact. One-fifth of the scans with the artefact were misinterpreted as pathology and half of these misinterpretations led to further action. Artefacts result in false diagnoses and unnecessary investigations; vigilance is needed. (orig.)

  10. Comparison of a dental cone beam CT with a multi-detector row CT on effective doses and physical image quality

    International Nuclear Information System (INIS)

    Yoshida, Yutaka; Tokumori, Kenji; Okamura, Kazutoshi; Yoshiura, Kazunori

    2011-01-01

    The purpose of this study was to compare a dental cone beam computed tomography (dental CBCT) and a multi-detector row CT (MDCT) using effective doses and physical image quality. A dental mode (D-mode) and an implant mode (I-mode) were employed for calculating effective doses. Field of view (FOV) size of the MDCT was 150 mm. Three types of images were obtained using 3 different reconstruction functions: FC1 (for abdomen images), FC30 (for internal ear and bone images) and FC81 (for high resolution images). Effective doses obtained with the D-mode and with the I-mode were about 20% and 50% of those obtained with the MDCT, respectively. Resolution properties obtained with the D-mode and I-mode were superior to that of the MDCT in a high frequency range. Noise properties of the D-mode and the I-mode were better than those with FC81. It was found that the dental CBCT has better potential as compared with MDCT in both dental and implant modes. (author)

  11. Multidetector row CT angiography of living related renal donors: Is there a need for venous phase imaging?

    International Nuclear Information System (INIS)

    Namasivayam, Saravanan; Kalra, Mannudeep K.; Waldrop, Sandra M.; Mittal, Pardeep K.; Small, William C.

    2006-01-01

    Objective: To prospectively evaluate whether renal venous anatomy can be detected from arterial phase images of multidetector row CT (MDCT) of renal donors. Material and methods: Institutional review board approved our study protocol with waiver of consent. Forty-eight consecutive renal donors (age range, 21-56 years; M:F, 20:28) referred for MDCT evaluation were included. Two sub-specialty radiologists performed an independent and separate evaluation of renal venous anatomy in arterial and venous phase images. Opacification of renal venous structures was scored on a five-point scale (1-not seen; 3-minimal opacification; 5-excellent opacification). Arterial and venous phase opacification scores were compared by Wilcoxon signed rank test. Results: Both readers detected all renal venous anomalies in arterial as well as venous phase images. Each reader detected accessory right renal veins (n = 14), retroaortic left renal vein (n = 2), circumaortic left renal vein (n = 1), and left renal hilar arteriovenous malformation (n = 1) in arterial phase images. Retroaortic left renal venous branch was difficult to differentiate from lumbar vein (reader-1, n = 1; reader-2, n = 2) in both arterial and venous phase images. Sensitivity of detection of renal veins, left adrenal, gonadal and lumbar veins in arterial phase images was 100, 83-88, 100, and 85-90%, respectively. As expected, venous phase images showed significantly greater opacification of renal veins, left gonadal, adrenal and lumbar veins (p < .05). However, this did not substantially limit the evaluation of renal venous anatomy in arterial phase images. Both readers had substantial interobserver agreement (kappa coefficient, 0.7; p < 0.05). Conclusions: Arterial phase MDCT images alone can be used to detect renal venous anomalies, and to identify small left renal venous branches namely, the left gonadal, adrenal and lumbar veins in renal donors. Venous phase MDCT acquisition is not necessary for evaluation of renal

  12. Multi-detector CT evaluation in patients suspected of tracheobronchomalacia: Comparison of end-expiratory with dynamic expiratory volumetric acquisitions

    Energy Technology Data Exchange (ETDEWEB)

    Ferretti, Gilbert R. [Department of Radiology (France)], E-mail: gferretti@chu-grenoble.fr; Jankowski, Adrien [Department of Radiology (France)], E-mail: ajankowski@chu-grenoble.fr; Perrin, Marie Amelie [Department of Radiology (France)], E-mail: maperrin@chu-grenoble.fr; Chouri, Nathalie [Department of Respiratory Diseases (France)], E-mail: nchouri@chu-grenoble.fr; Arnol, Nathalie [Sleep Laboratory and EFCR, University Hospital, Grenoble (France); HP2 Laboratory, INSERM ERI 0017 (Hypoxia: Pathophysiology), Joseph Fourier University, Grenoble (France)], E-mail: narnold@chu-grenoble.fr; Aubaud, Laurent [Department of Radiology (France)], E-mail: laubaud@chu-grenoble.fr; Pepin, Jean-Louis [Sleep Laboratory and EFCR, University Hospital, Grenoble (France); HP2 Laboratory, INSERM ERI 0017 (Hypoxia: Pathophysiology), Joseph Fourier University, Grenoble (France)], E-mail: jlpepin@chu-grenoble.fr

    2008-11-15

    Purpose: The aim of this study was to compare dynamic expiratory imaging and end-expiratory imaging using multi-detector CT (MDCT) of the central airways in patients suspected of tracheobronchomalacia (TBM). Methods: This study had local ethical committee approval. Seventy patients suspected of TBM were prospectively included. All patients underwent evaluation of central airways by three different low-dose MDCT acquisitions: end inspiration, end expiration, and dynamic expiration. Degree of airway collapse was measured by calculating the percentage change in the area and diameter of the airways between inspiratory and the two expiratory techniques at three levels of the trachea and in the sagittal diameter of the right and left main bronchi. Three threshold levels of percentage reduction in diameter or area (30%, 50%, and 70%) for defining TBM were evaluated. Results: In the entire population, the mean percentage of airway collapse was significantly greater with dynamic expiratory imaging than with the end-expiratory imaging at three different levels: lower thoracic trachea (26% vs. 16.6%, p < 0.009), right (25.2% vs. 14%, p < 0.01) and left main (24.7% vs. 13.3%, p < 0.01) bronchus. Whatever the threshold value for defining TBM, dynamic expiratory imaging always resulted in diagnosing TBM in more patients than end-expiratory imaging. Conclusions: Dynamic expiratory imaging shows a significantly greater degree and a significantly greater extent of airway collapse than standard end-expiratory imaging in patients suspected of TBM. Further evaluation of the clinical relevance of such findings is warranted.

  13. Multidetector row CT angiography of living related renal donors: Is there a need for venous phase imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Namasivayam, Saravanan [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Kalra, Mannudeep K. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Waldrop, Sandra M. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Mittal, Pardeep K. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Small, William C. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States)]. E-mail: wsmall@emory.edu

    2006-09-15

    Objective: To prospectively evaluate whether renal venous anatomy can be detected from arterial phase images of multidetector row CT (MDCT) of renal donors. Material and methods: Institutional review board approved our study protocol with waiver of consent. Forty-eight consecutive renal donors (age range, 21-56 years; M:F, 20:28) referred for MDCT evaluation were included. Two sub-specialty radiologists performed an independent and separate evaluation of renal venous anatomy in arterial and venous phase images. Opacification of renal venous structures was scored on a five-point scale (1-not seen; 3-minimal opacification; 5-excellent opacification). Arterial and venous phase opacification scores were compared by Wilcoxon signed rank test. Results: Both readers detected all renal venous anomalies in arterial as well as venous phase images. Each reader detected accessory right renal veins (n = 14), retroaortic left renal vein (n = 2), circumaortic left renal vein (n = 1), and left renal hilar arteriovenous malformation (n = 1) in arterial phase images. Retroaortic left renal venous branch was difficult to differentiate from lumbar vein (reader-1, n = 1; reader-2, n = 2) in both arterial and venous phase images. Sensitivity of detection of renal veins, left adrenal, gonadal and lumbar veins in arterial phase images was 100, 83-88, 100, and 85-90%, respectively. As expected, venous phase images showed significantly greater opacification of renal veins, left gonadal, adrenal and lumbar veins (p < .05). However, this did not substantially limit the evaluation of renal venous anatomy in arterial phase images. Both readers had substantial interobserver agreement (kappa coefficient, 0.7; p < 0.05). Conclusions: Arterial phase MDCT images alone can be used to detect renal venous anomalies, and to identify small left renal venous branches namely, the left gonadal, adrenal and lumbar veins in renal donors. Venous phase MDCT acquisition is not necessary for evaluation of renal

  14. A Comparison of the Use of Contrast Media with Different Iodine Concentrations for Multidetector CT of the Kidney

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Seung Chai; Kim, Seung Hyup; Cho, Jeong Yeon [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2011-11-15

    To determine the optimal iodine concentration of contrast media for kidney multidetector computed tomography (MDCT) by comparing the degree of renal parenchymal enhancement and the severity of the renal streak artifact with contrast media of different iodine concentrations. A 16-row MDCT was performed in 15 sedated rabbits by injection of 2 mL contrast media/kg body weight at a rate of 0.3 mL/sec. Monomeric nonionic contrast media of 250, 300, and 370 mg iodine/mL were injected at 1-week intervals. Mean attenuation values were measured in each renal structure with attenuation differences among the structures. The artifact was evaluated by CT window width/level and three grading methods. The values were compared with iodine concentrations. The 370 mg iodine/mL concentration showed significantly higher cortical enhancement than 250 mg iodine/mL in all phases (p < 0.05). There was however no significant difference in the degree of enhancement between the 300 mg iodine/mL and 370 mg iodine/mL concentrations in all phases. There is a significant difference in attenuation for the cortex-outer medulla between 250 mg iodine/mL and 300 mg iodine/mL (p < 0.05). The artifact was more severe with a medium of 370 mg iodine/mL than with 250 mg iodine/mL by all grading methods (p < 0.05). The 300 mg iodine/mL is considered to be the most appropriate iodine concentration in an aspect of the enhancement and artifact on a kidney MDCT scan.

  15. Balancing Radiation and Contrast Media Dose in Single-Pass Abdominal Multidetector CT: Prospective Evaluation of Image Quality.

    Science.gov (United States)

    Camera, Luigi; Romano, Federica; Liccardo, Immacolata; Liuzzi, Raffaele; Imbriaco, Massimo; Mainenti, Pier Paolo; Pizzuti, Laura Micol; Segreto, Sabrina; Maurea, Simone; Brunetti, Arturo

    2015-11-01

    As both contrast and radiation dose affect the quality of CT images, a constant image quality in abdominal contrast-enhanced multidetector computed tomography (CE-MDCT) could be obtained balancing radiation and contrast media dose according to the age of the patients. Seventy-two (38 Men; 34 women; aged 20-83 years) patients underwent a single-pass abdominal CE-MDCT. Patients were divided into three different age groups: A (20-44 years); B (45-65 years); and C (>65 years). For each group, a different noise index (NI) and contrast media dose (370 mgI/mL) was selected as follows: A (NI, 15; 2.5 mL/kg), B (NI, 12.5; 2 mL/kg), and C (NI, 10; 1.5 mL/kg). Radiation exposure was reported as dose-length product (DLP) in mGy × cm. For quantitative analysis, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated for both the liver (L) and the abdominal aorta (A). Statistical analysis was performed with a one-way analysis of variance. Standard imaging criteria were used for qualitative analysis. Although peak hepatic enhancement was 152 ± 16, 128 ± 12, and 101 ± 14 Hounsfield units (P contrast media dose (mL) administered were 476 ± 147 and 155 ± 27 for group A, 926 ± 291 and 130 ± 16 for group B, and 1981 ± 451 and 106 ± 15 for group C, respectively (P contrast media dose administered to patients of different age. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  16. A Comparison of the Use of Contrast Media with Different Iodine Concentrations for Multidetector CT of the Kidney

    Science.gov (United States)

    Jung, Seung Chai; Cho, Jeong Yeon

    2011-01-01

    Objective To determine the optimal iodine concentration of contrast media for kidney multidetector computed tomography (MDCT) by comparing the degree of renal parenchymal enhancement and the severity of the renal streak artifact with contrast media of different iodine concentrations. Materials and Methods A 16-row MDCT was performed in 15 sedated rabbits by injection of 2 mL contrast media/kg body weight at a rate of 0.3 mL/sec. Monomeric nonionic contrast media of 250, 300, and 370 mg iodine/mL were injected at 1-week intervals. Mean attenuation values were measured in each renal structure with attenuation differences among the structures. The artifact was evaluated by CT window width/level and three grading methods. The values were compared with iodine concentrations. Results The 370 mg iodine/mL concentration showed significantly higher cortical enhancement than 250 mg iodine/mL in all phases (p < 0.05). There was however no significant difference in the degree of enhancement between the 300 mg iodine/mL and 370 mg iodine/mL concentrations in all phases. There is a significant difference in attenuation for the cortex-outer medulla between 250 mg iodine/mL and 300 mg iodine/mL (p < 0.05). The artifact was more severe with a medium of 370 mg iodine/mL than with 250 mg iodine/mL by all grading methods (p < 0.05). Conclusion The 300 mg iodine/mL is considered to be the most appropriate iodine concentration in an aspect of the enhancement and artifact on a kidney MDCT scan. PMID:22043154

  17. Thin-section multiplanar reformats from multidetector-row CT data: Utility for assessment of regional tumor extent in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Higashino, Takanori; Ohno, Yoshiharu; Takenaka, Daisuke; Watanabe, Hirokazu; Nogami, Munenobu; Ohbayashi, Chiho; Yoshimura, Masahiro; Satouchi, Miyako; Nishimura, Yoshihiro; Fujii, Masahiko; Sugimura, Kazuro

    2005-01-01

    Purpose: To determine the clinical utility of thin-section multiplanar reformats (MPRs) from multidetector-row CT (MDCT) data sets for assessing the extent of regional tumors in non-small cell lung cancer (NSCLC) patients. Materials and methods: Sixty consecutive NSCLC patients, who were considered candidates for surgical treatment, underwent contrast-enhanced MDCT examinations, surgical resection and pathological examinations. All MDCT examinations were performed with a 4-detector row computed tomography (CT). From each raw CT data set, 5 mm section thickness CT images (routine CT), 1.25 mm section thickness CT images (thin-section CT) and 1.25 mm section thickness sagittal (thin-section sagittal MPR) and coronal images (thin-section coronal MPR) were reconstructed. A 4-point visual score was used to assess mediastinal, interlobar and chest wall invasions on each image set. For assessment of utility in routine clinical practice, mean reading times for each image set were compared by means of Fisher's protected least significant difference (PLSD) test. A receiver operator characteristic (ROC) analysis was performed to determine the diagnostic capability of each of the image data sets. Finally, sensitivity, specificity and accuracy of the reconstructed images were compared by McNemar test. Results: Mean reading times for thin-section sagittal and coronal MPRs were significantly shorter than those for routine CT and thin-section CT (p < 0.05). Areas under the curve (Azs) showing interlobar invasion on thin-section sagittal and coronal MPRs were significantly larger than that on routine CT (p = 0.03), and the Az on thin-section sagittal MPR was also significantly larger than that on routine CT (p = 0.02). Accuracy of chest wall invasion by thin-section sagittal MPR was significantly higher than that by routine CT (p = 0.04). Conclusion: Thin-section multiplanar reformats from multidetector-row CT data sets are useful for assessing the extent of regional tumors in non

  18. Computer-aided detection of lung nodules on multidetector CT in concurrent-reader and second-reader modes: A comparative study

    International Nuclear Information System (INIS)

    Matsumoto, Sumiaki; Ohno, Yoshiharu; Aoki, Takatoshi; Yamagata, Hitoshi; Nogami, Munenobu; Matsumoto, Keiko; Yamashita, Yoshiko; Sugimura, Kazuro

    2013-01-01

    Purpose: To compare the reading times and detection performances of radiologists in concurrent-reader and second-reader modes of computer-aided detection (CAD) for lung nodules on multidetector computed tomography (CT). Materials and Methods: Fifty clinical multidetector CT datasets containing nodules up to 20 mm in diameter were retrospectively collected. For the detection and rating of non-calcified nodules larger than 4 mm in diameter, 6 radiologists (3 experienced radiologists and 3 resident radiologists) independently interpreted these datasets twice, once with concurrent-reader CAD and once with second-reader CAD. The reference standard of nodules in the datasets was determined by the consensus of two experienced chest radiologists. The reading times and detection performances in the two modes of CAD were statistically compared, where jackknife free-response receiver operating characteristic (JAFROC) analysis was used for the comparison of detection performances. Results: Two hundreds and seven nodules constituted the reference standard. Reading time was significantly shorter in the concurrent-reader mode than in the second-reader mode, with the mean reading time for the 6 radiologists being 132 s with concurrent-reader CAD and 210 s with second-reader CAD (p < 0.01). JAFROC analysis revealed no significant difference between the detection performances in the two modes, with the average figure-of-merit value for the 6 radiologists being 0.70 with concurrent-reader CAD and 0.72 with second-reader CAD (p = 0.35). Conclusion: In CAD for lung nodules on multidetector CT, the concurrent-reader mode is more time-efficient than the second-reader mode, and there can be no significant difference between the two modes in terms of detection performance of radiologists

  19. In vitro evaluation of 56 coronary artery stents by 256-slice multi-detector coronary CT

    International Nuclear Information System (INIS)

    Steen, Henning; Andre, Florian; Korosoglou, Grigorios; Mueller, Dirk; Hosch, Waldemar; Kauczor, Hans-Ulrich; Giannitsis, Evangelos; Katus, Hugo A.

    2011-01-01

    Objective: We sought to investigate stent lumen visibility of 56 coronary stents with the newest 256-multi-slice-CT (256-MDCT) technology for different reconstruction algorithms in an in vitro model. Background: Early identification of in-stent restenosis (ISR) is important to avoid recurrent ischemia and prevent acute myocardial infarction (AMI). Since angiography has the disadvantage of high costs and its invasiveness, MDCT could be a convenient and safe non-invasive alternative for detection of ISR. Material and methods: Percentages of in-stent lumen diameter and in-stent signal attenuation (measured as contrast-to-noise ratio (CNR)) of 56 coronary stents (group A ≤2.5 mm; group B = 2.75-3.0 mm; group C = 3.5-4.0 mm) were evaluated in a coronary vessel in vitro phantom (iodine-filled plastic tubes) employing four different reconstruction algorithms (XCD, CC, CD, XCB) on a novel 256-MDCT (Philips-iCT, collimation = 128 mm x 0.625 mm; rotation time = 270 ms; tube current = 800 mA s with 120 kV). Analysis was conducted with the semi-automatical full-width-at-half-maximum (FWHM) method. P-values 60% for group C stents was significantly larger and CNR was significantly lower (both p 3.0 mm when analysed with cardio-dedicated sharp kernels, although clinical studies corroborating this claim should be performed. However, stents ≤3.0 mm reconstructed by soft kernels revealed insufficient in-stent lumen visualisation and should not be used in clinical practice. Further improvements in spatial and temporal image resolution as well as reductions of radiation exposure and image noise have to be accomplished for the ambitious goal of characterising both CT coronary artery anatomy and in-stent lumen.

  20. The Role of Spiral Multidetector Dynamic CT in the Study of Williams-Campbell Syndrome

    International Nuclear Information System (INIS)

    Scioscio, V. di; Zompatori, M.; Mistura, I.; Montanari, P.; Santilli, L.; Luccaroni, R.; Sverzellati, N.

    2006-01-01

    Williams-Campbell syndrome is a cystic bronchiectatic disease secondary to deficiency or defect of cartilaginous plates in the wall of the airways. In the literature, two main forms are suggested: congenital and acquired (post-infectious). The most frequent symptoms are represented by recurrent pulmonary infections from childhood. Multislice spiral dynamic CT has a major role in the study of cystic pulmonary disease and in differentiating Williams-Campbell syndrome from the other causes of cystic bronchiectasis, in which even lung function tests can give deceptive results

  1. The Role of Spiral Multidetector Dynamic CT in the Study of Williams-Campbell Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Scioscio, V. di; Zompatori, M.; Mistura, I.; Montanari, P.; Santilli, L.; Luccaroni, R.; Sverzellati, N. [Medical Univ. of Bologna, S. Orsola-Malpighi Policlinic (Italy). Dept. of Radiology

    2006-10-15

    Williams-Campbell syndrome is a cystic bronchiectatic disease secondary to deficiency or defect of cartilaginous plates in the wall of the airways. In the literature, two main forms are suggested: congenital and acquired (post-infectious). The most frequent symptoms are represented by recurrent pulmonary infections from childhood. Multislice spiral dynamic CT has a major role in the study of cystic pulmonary disease and in differentiating Williams-Campbell syndrome from the other causes of cystic bronchiectasis, in which even lung function tests can give deceptive results.

  2. Comparison of low dose with standard dose abdominal/pelvic multidetector CT in patients with stage 1 testicular cancer under surveillance

    Energy Technology Data Exchange (ETDEWEB)

    O' Malley, Martin E. [Joint Department of Medical Imaging, Toronto, ON (Canada); Chung, Peter; Warde, Padraig [Princess Margaret Hospital, Department of Radiation Oncology, Toronto, ON (Canada); Haider, Masoom; Jhaveri, Kartik; Khalili, Korosh [Princess Margaret Hospital, Joint Department of Medical Imaging, Toronto, ON (Canada); Jang, Hyun-Jung [Toronto General Hospital, Joint Department of Medical Imaging, Toronto, ON (Canada); Panzarella, Tony [Princess Margaret Hospital, Department of Biostatistics, Toronto, ON (Canada)

    2010-07-15

    To compare the image quality and acceptability of a low dose with those of standard dose abdominal/pelvic multidetector CT in patients with stage 1 testicular cancer managed by surveillance. One hundred patients (median age 31 years; range 19-83 years), 79 with seminoma and 21 with non-seminoma, underwent abdominal/pelvic imaging with low and standard dose protocols on 64-slice multidetector CT. Three reviewers independently evaluated images for noise and diagnostic quality on a 5-point scale and for diagnostic acceptability. On average, each reader scored noise and diagnostic quality of standard dose images significantly better than corresponding low dose images (p < 0.0001). One reader found all CT examinations acceptable; two readers each found 1/100 (1%) low dose examinations unacceptable. Median and mean dose-length product for low and standard dose protocols were 416.0 and 452.2 (range 122.9-913.4) and 931.9 and 999.8 (range 283.8-1,987.7) mGy cm, respectively. The low dose protocol provided diagnostically acceptable images for at least 99% of patients and achieved mean dose reduction of 55% compared with the standard dose protocol. (orig.)

  3. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung [Mokdong Hospital, Ewha Womans University, Seoul (Korea, Republic of)

    2006-04-15

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure.

  4. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    International Nuclear Information System (INIS)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung

    2006-01-01

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure

  5. A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations

    International Nuclear Information System (INIS)

    Turner, Adam C.; Zhang Di; Kim, Hyun J.; DeMarco, John J.; Cagnon, Chris H.; Angel, Erin; Cody, Dianna D.; Stevens, Donna M.; Primak, Andrew N.; McCollough, Cynthia H.; McNitt-Gray, Michael F.

    2009-01-01

    The purpose of this study was to present a method for generating x-ray source models for performing Monte Carlo (MC) radiation dosimetry simulations of multidetector row CT (MDCT) scanners. These so-called ''equivalent'' source models consist of an energy spectrum and filtration description that are generated based wholly on the measured values and can be used in place of proprietary manufacturer's data for scanner-specific MDCT MC simulations. Required measurements include the half value layers (HVL 1 and HVL 2 ) and the bowtie profile (exposure values across the fan beam) for the MDCT scanner of interest. Using these measured values, a method was described (a) to numerically construct a spectrum with the calculated HVLs approximately equal to those measured (equivalent spectrum) and then (b) to determine a filtration scheme (equivalent filter) that attenuates the equivalent spectrum in a similar fashion as the actual filtration attenuates the actual x-ray beam, as measured by the bowtie profile measurements. Using this method, two types of equivalent source models were generated: One using a spectrum based on both HVL 1 and HVL 2 measurements and its corresponding filtration scheme and the second consisting of a spectrum based only on the measured HVL 1 and its corresponding filtration scheme. Finally, a third type of source model was built based on the spectrum and filtration data provided by the scanner's manufacturer. MC simulations using each of these three source model types were evaluated by comparing the accuracy of multiple CT dose index (CTDI) simulations to measured CTDI values for 64-slice scanners from the four major MDCT manufacturers. Comprehensive evaluations were carried out for each scanner using each kVp and bowtie filter combination available. CTDI experiments were performed for both head (16 cm in diameter) and body (32 cm in diameter) CTDI phantoms using both central and peripheral measurement positions. Both equivalent source model types

  6. Utilization of low-dose multidetector CT and virtual bronchoscopy in children with suspected foreign body aspiration

    International Nuclear Information System (INIS)

    Adaletli, Ibrahim; Kurugoglu, Sebuh; Ulus, Sila; Ozer, Harun; Kantarci, Fatih; Mihmanli, Ismail; Akman, Canan; Elicevik, Mehmet

    2007-01-01

    Foreign body aspiration is common in children, especially those under 3 years of age. Chest radiography and CT are the main imaging modalities for the evaluation of these children. Management of children with suspected foreign body aspiration (SFBA) mainly depends on radiological findings. To investigate the potential use of low-dose multidetector CT (MDCT) and virtual bronchoscopy (VB) in the evaluation and management of SFBA in children. Included in the study were 37 children (17 girls, 20 boys; age 4 months to 10 years, mean 32 months) with SFBA. Chest radiographs were obtained prior to MDCT in all patients. MDCT was performed using a low-dose technique. VB images were obtained in the same session. Conventional bronchoscopy (CB) was performed within 24 h on patients in whom an obstructive abnormality had been found by MDCT and VB. Obstructive pathology was found in 16 (43.25%) of the 37 patients using MDCT and VB. In 13 of these patients, foreign bodies were detected and removed via CB. The foreign bodies were located in the right main bronchus (n = 5), in the bronchus intermedius (n = 6), in the medial segment of the middle lobe bronchus (n = 1), and in the left main bronchus (n = 1). In the remaining three patients, the diagnosis was false-positive for an obstructive pathology by MDCT and VB; the final diagnoses were secretions (n = 2) and schwannoma (n = 1), as demonstrated by CB. In 21 patients in whom no obstructive pathology was detected by MDCT and VB, CB was not performed. These patients were followed for 5-20 months without any recurrent obstructive symptomatology. Low-dose MDCT and VB are non-invasive radiological modalities that can be used easily in the investigation of SFBA in children. MDCT and VB provide the exact location of the obstructive pathology prior to CB. If obstructive pathology is depicted with MDCT and VB, CB should be performed either for confirmation of the diagnosis or for the diagnosis of an alternative cause for the obstruction

  7. Upper abdominal gadoxetic acid-enhanced and diffusion-weighted MRI for the detection of gastric cancer: Comparison with two-dimensional multidetector row CT

    International Nuclear Information System (INIS)

    Jang, K.M.; Kim, S.H.; Lee, S.J.; Lee, M.W.; Choi, D.; Kim, K.M.

    2014-01-01

    Aim: To evaluate the diagnostic performance of abdominal magnetic resonance imaging (MRI) for the detection of gastric cancer in comparison with that of two-dimensional (2D) multidetector row computed tomography (CT). Materials and methods: The study included 189 patients with 170 surgically confirmed gastric cancers and 19 patients without gastric cancer, all of whom underwent gadoxetic acid-enhanced MRI with diffusion-weighted (DW) imaging, and multidetector contrast-enhanced abdominal CT imaging. Two observers independently analysed three sets of images (CT set, conventional MRI set, and combined conventional and DW MRI set). A five-point scale for likelihood of gastric cancer was used. Diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were evaluated. Quantitative [apparent diffusion coefficient (ADC) analyses with Mann–Whitney U-test were conducted for gastric cancers and the nearby normal gastric wall. Results: The diagnostic accuracy and sensitivity for detection of gastric cancer were significantly higher on combined conventional and DW MRI set (77.8–78.3%; 75.3–75.9%) than the CT imaging set (67.7–71.4%; 64.1–68.2%) or the conventional MRI set (72–73%; 68.8–70%; p < 0.01). In particular, for gastric cancers with pT2 and pT3, the combined conventional and DW MRI set (91.6–92.6%) yielded significantly higher sensitivity for detection of gastric cancer than did the CT imaging set (76.8–81.1%) by both observers (p < 0.01). The mean ADC of gastric cancer lesions (1 ± 0.23 × 10 −3 mm 2 /s) differed significantly from that of normal gastric wall (1.77 ± 0.25 × 10 −3  mm 2 /s; p < 0.01). Conclusion: Abdominal MRI with DW imaging was more sensitive for the detection of gastric cancer than 2D-multidetector row CT or conventional MRI alone. - Highlights: • The sensitivity for detection of gastric cancer is high on abdominal MR imaging. • DW imaging is helpful for

  8. Multidetector-CT angiography in pulmonary embolism - can image parameters predict clinical outcome?

    Energy Technology Data Exchange (ETDEWEB)

    Heyer, Christoph M.; Lemburg, Stefan P.; Nicolas, Volkmar; Roggenland, Daniela [Berufsgenossenschaftliches Universitaetsklinikum Bergmannsheil GmbH, Ruhr-University of Bochum, Institute of Diagnostic Radiology, Interventional Radiology and Nuclear Medicine, Bochum (Germany); Knoop, Heiko [Berufsgenossenschaftliches Universitaetsklinikum Bergmannsheil GmbH, Medical Clinic III - Pneumology, Allergology, and Sleep Medicine, Bochum (Germany); Holland-Letz, Tim [Ruhr-University of Bochum, Department of Medical Informatics, Biometry and Epidemiology, Bochum (Germany)

    2011-09-15

    To assess if pulmonary CT angiography (CTA) can predict outcome in patients with pulmonary embolism (PE). Retrospective analysis of CTA studies of patients with PE and documentation of pulmonary artery (PA)/aorta ratio, right ventricular (RV)/left ventricular (LV) ratio, superior vena cava (SVC) diameter, pulmonary obstruction index (POI), ventricular septal bowing (VSB), venous contrast reflux (VCR), pulmonary infarction and pleural effusion. Furthermore, duration of total hospital stay, necessity for/duration of ICU therapy, necessity for mechanical ventilation and mortality were recorded. Comparison was performed by logistic/linear regression analysis with significance at 5%. 152 patients were investigated. Mean duration of hospital stay was 21 {+-} 24 days. 66 patients were admitted to the ICU; 20 received mechanical ventilation. Mean duration of ICU therapy was 3 {+-} 8 days. Mortality rate was 8%. Significant positive associations of POI, VCR and pulmonary infarction with necessity for ICU therapy were shown. VCR was significantly associated with necessity for mechanical ventilation and duration of ICU treatment. Pleural effusions were significantly associated with duration of total hospital stay whereas the RV/LV ratio correlated with mortality. Selected CTA findings showed significant associations with the clinical course of PE and may thus be used as predictive parameters. (orig.)

  9. Variations of right bronchial tree: a study with multi-detector CT.

    Science.gov (United States)

    Wang, Tao; Meng, Min; Huang, Min; Zhao, Xinya

    2018-05-03

    The aim was to display variations of right bronchial tree. The bronchial tree images of 238 patients were reconstructed using the postprocessing technique of CT. We revealed four cases rare bronchial branching patterns of right superior lobe. 1 case was referred to as tracheal bronchus. In 1 case, B1 was located in the place of the right superior lobar bronchus and B2 + 3 arose from the right merge of the IB. In 1 case, the right superior lobar bronchus has only two divisions for B1 and B3, and the bronchus B2 arose from the right merge of the IB. In 1 case, B1 branched into four bronchi. We revealed 15 cases of rare bronchial branching patterns of right inferior lobe. In nine cases, the basal trunk bronchus bifurcated into B7 + 8 and B9 + l0. In three cases, B8 branched from the basal trunk bronchus before B7. In two cases, basal trunk bronchus bifurcated into B7 + 8 + 9 and B10. In 1 case, the basal trunk bronchus bifurcated into the common stem of B7 + 10 and B8 + 9. Variations of right bronchial tree were displayed in the present study. This information may have important implications for diagnosis of symptomatic patients and performing certain procedures, including bronchoscopy, endotracheal intubation, and lung resection.

  10. Effect of computer-aided detection as a second reader in multidetector-row CT colonography

    International Nuclear Information System (INIS)

    Mang, Thomas; Peloschek, Philipp; Plank, Christina; Maier, Andrea; Weber, Michael; Herold, Christian; Schima, Wolfgang; Graser, Anno; Bogoni, Luca

    2007-01-01

    Our purpose was to assess the effect of computer-aided detection (CAD) on lesion detection as a second reader in computed tomographic colonography, and to compare the influence of CAD on the performance of readers with different levels of expertise. Fifty-two CT colonography patient data-sets (37 patients: 55 endoscopically confirmed polyps ≥0.5 cm, seven cancers; 15 patients: no abnormalities) were retrospectively reviewed by four radiologists (two expert, two nonexpert). After primary data evaluation, a second reading augmented with findings of CAD (polyp-enhanced view, Siemens) was performed. Sensitivities and reading time were calculated for each reader without CAD and supported by CAD findings. The sensitivity of expert readers was 91% each, and of nonexpert readers, 76% and 75%, respectively, for polyp detection. CAD increased the sensitivity of expert readers to 96% (P = 0.25) and 93% (P = 1), and that of nonexpert readers to 91% (P = 0.008) and 95% (P = 0.001), respectively. All four readers diagnosed 100% of cancers, but CAD alone only 43%. CAD increased reading time by 2.1 min (mean). CAD as a second reader significantly improves sensitivity for polyp detection in a high disease prevalence population for nonexpert readers. CAD causes a modest increase in reading time. CAD is of limited value in the detection of cancer. (orig.)

  11. Multidetector CT Patterns of Peritoneal Involvement in Patients with Abdominopelvic Malignancies

    International Nuclear Information System (INIS)

    Yawar, B.; Babar, S.; Rehman, I.; Sana, F.; Javed, F.; Chaudhary, M. Y.

    2015-01-01

    Objective: To determine the patterns of peritoneal involvement in patients with abdominopelvic malignancies. Study Design:Retrospective observational study. Place and Duration of Study: Shifa International Hospital, Islamabad, Pakistan, from May 2004 to May 2012. Methodology: Two hundred and three patients with histopathologically proven abdominopelvic malignancies with peritoneal involvement who underwent contrast-enhanced CT abdomen and pelvis were identified through electronic data base system and were included in this study after ethical committee approval. Peritoneal disease pattern, predominant sites of involvement and associated findings of ascites, lymph nodes and metastasis were assessed. Patients with tuberculosis and lymphoproliferative disorders were excluded. Results: The malignancies showing peritoneal involvement, in decreasing order of frequency, were ovarian cancer (n=118), colorectal cancer (n=45), pancreatic cancer (n=11), gastric cancer (n=7), endometrial cancer (n=6), gallbladder/ challenge-carcinoma and hepatocellular cancer (n=5 each), cervical cancer (n=3), renal cell carcinoma (n=2) and transitional cell urinary bladder cancer (n=1). The most common pattern of peritoneal involvement was mixed in 79 patients (39 percentage), omental caking in 74 patients (37 percentage) and nodular deposits in 50 patients (24 percentage). The most common sites of peritoneal involvement were pelvic peritoneum followed by greater omentum. Conclusion: Peritoneal involvement is the commonest with ovarian and colorectal carcinoma. Mixed pattern of peritoneal disease was most frequently seen in these patients followed by omental caking and nodular peritoneal deposits. (author)

  12. ECG-triggered MDR-CT for the detection of pulmonary metastases

    International Nuclear Information System (INIS)

    Pauls, S.; Wahl, J.; Aschoff, A.J.; Brambs, H.J.; Fleiter, T.R.

    2003-01-01

    Purpose: Comparison of multidetector-row CT (MDR-CT) of the chest with and without ECG triggering for the detection of pulmonary metastases. Materials and Methods: Fifty patients with malignant tumors underwent CT of the chest. The unenhanced phase was performed with ECG-triggered MDR-CT and the contrast-enhanced phase with helical MDR-CT. The ECG-triggered and standard helical scans were interpreted in separate sessions, with the analysis determining the number and demarcation of the intrapulmonary nodules and the delineation of the mediastinal structure (rated 1 = excellent to 5 = poor). Results: ECG-MDR-CT images detected 38% more pulmonary nodules than MDR-CT. The detection rate for tumors [de

  13. Measurement of the aortic diameter in the asymptomatic Korean population: Assessment with multidetector CT

    International Nuclear Information System (INIS)

    Lee, Sang Hwan; Lee, Whal; Choi, Hyuck Jae; Kim, Dae Jin; Park, Eun Ah; Chung, Jin Wook; Park, Jae Hyung

    2013-01-01

    To determine normal reference values for aortic diameters in asymptomatic Korean adults. Three hundred adults without signs or symptoms of cardiovascular diseases were enrolled in this study. Aortic diameters were measured at nine predetermined levels on CT images. Aortic diameter measurements were adjusted for body surface area. Analysis of data was performed with regard to age, sex, weight, height and hypertension. Aortic diameters were 2.99 ± 0.57 cm at the ascending aorta, 2.54 ± 0.35 cm at the transverse aortic arch, 2.36 ± 0.35 cm at the proximal descending thoracic aorta (DTA), 2.23 ± 0.37 cm at the mid DTA, 2.17 ± 0.38 cm at the distal DTA, 2.16 ± 0.37 cm at the thoracoabdominal junction, 2.10, 00B1, 0.35 cm at the level of the celiac axis, 1.94, 00B1, 0.36 cm at the suprarenal aorta, 1.58 ± 0.24 cm at the aortic bifurcation. Men had slightly larger diameters than women (p < 0.05). All diameters increased with age and hypertension, with statistical significance (p < 0.01). And all aortic diameters increased with height (p < 0.05) except at the level of the aortic arch (p = 0.056), and increased with weight (p < 0.05) except at the level of the suprarenal aorta (p = 0.067). Male sex, higher weight and height, age and hypertension are associated with larger aortic diameters in asymptomatic Korean adults.

  14. The study of multi-detector CT on the grouping and measuring of the hepatic veins

    International Nuclear Information System (INIS)

    Wang Xianliang; Dong Guang; Geng Hai; Wang Wengang; Li Linkun; Gao Wei; Wang Rongfang

    2007-01-01

    Objective: To study the three-dimensional topography of the hepatic vein (HV), the inferior vena cava(IVC) and the inferior right hepatic vein(IRHV) in the retrohepatic and pre-IVC tunnel in human beings, and to provide an anatomic reference for liver surgery. Methods: One hundred and ten volunteers underwent CT scanning at 60 to 75 s after injection of contrast medium, and their HV, IVC and IRHV were reconstructed into MPR and 3D-MIP images. The hepatic veins were grouped according to the way by which the hepatic vein enters IVC. The angle between the right hepatic vein and the middle hepatic vein or the trunk of hepatic vein was measured, and the width from right hepatic vein to middle hepatic vein or to the trunk of hepatic vein on IVC was recorded. The frequency of IRHV was observed, and the length of the tunnel was measured. Results: Among the 110 volunteers, there were 6 cases (5.45%) with three hepatic veins respectively entering IVC, 98 cases (89.10%) with right hepatic vein and a common trunk of the middle hepatic vein and the left hepatic vein entering IVC, and 6 cases (5.45%) with left hepatic vein and a common trunk of the right hepatic vein and the middle hepatic vein entering IVC. The mean value of the angles between the right hepatic vein and the middle hepatic vein or the mink of hepatic vein was (55 ± 18) degree. The width from the right hepatic vein to the middle hepatic vein or to the trunk of hepatic vein was (21 ± 7)mm. The IRHV was observed in 30 cases(27.27%). The mean value of the tunnel length was (53 ± 11) mm. Conclusion: The parameters of the retrohepatic and pre-IVC tunnel in human beings can be measured accurately by the imaging of MPR, which can provide an anatomic reference for the liver surgery. (authors)

  15. Prospective comparative study between un-enhanced multidetector ...

    African Journals Online (AJOL)

    Rehab Abdel Rahman El Bakry

    lyceal dilatation.2 Furthermore sometimes extra-renal pelvis or pelvi-ureteral stricture ... especially in acute renal colic.6 This technique showed high sensi- ... ray voltage of 140–120kV, and a current of 230–350mA, slice ... Statistical analysis.

  16. Dynamic multidetector CT and non-contrast-enhanced MR for right adrenal vein imaging: comparison with catheter venography in adrenal venous sampling

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Hideki; Seiji, Kazumasa; Kawabata, Masahiro; Satani, Nozomi; Matsuura, Tomonori; Tominaga, Junya; Takase, Kei [Tohoku University Hospital, Department of Diagnostic Radiology, Sendai (Japan); Omata, Kei; Ono, Yoshikiyo; Iwakura, Yoshitsugu; Morimoto, Ryo; Kudo, Masataka; Satoh, Fumitoshi; Ito, Sadayoshi [Tohoku University Hospital, Division of Nephrology, Endocrinology and Vascular Medicine, Sendai (Japan)

    2016-03-15

    To evaluate visualization of the right adrenal vein (RAV) with multidetector CT and non-contrast-enhanced MR imaging in patients with primary aldosteronism. A total of 125 patients (67 men) scheduled for adrenal venous sampling (AVS) were included. Dynamic 64-detector-row CT and balanced steady-state free precession-based non-contrast-enhanced 3-T MR imaging were performed. RAV visualization based on a four-point score was documented. Both anatomical location and variation on cross-sectional imaging were evaluated, and the findings were compared with catheter venography as the gold standard. The RAV was visualized in 93.2 % by CT and 84.8 % by MR imaging (p = 0.02). Positive predictive values of RAV visualization were 100 % for CT and 95.2 % for MR imaging. Imaging score was significantly higher in CT than MR imaging (p < 0.01). The RAV formed a common trunk with an accessory hepatic vein in 16 % of patients. The RAV orifice level on cross-sectional imaging was concordant with catheter venography within the range of 1/3 vertebral height in >70 % of subjects. Success rate of AVS was 99.2 %. Dynamic CT is a reliable way to map the RAV prior to AVS. Non-contrast-enhanced MR imaging is an alternative when there is a risk of complication from contrast media or radiation exposure. (orig.)

  17. Safe cervical spine clearance in adult obtunded blunt trauma patients on the basis of a normal multidetector CT scan--a meta-analysis and cohort study.

    Science.gov (United States)

    Raza, Mushahid; Elkhodair, Samer; Zaheer, Asif; Yousaf, Sohail

    2013-11-01

    A true gold standard to rule out a significant cervical spine injury in subset of blunt trauma patients with altered sensorium is still to be agreed upon. The objective of this study is to determine whether in obtunded adult patients with blunt trauma, a clinically significant injury to the cervical spine be ruled out on the basis of a normal multidetector cervical spine computed tomography. Comprehensive database search was conducted to include all the prospective and retrospective studies on blunt trauma patients with altered sensorium undergoing cervical spine multidetector CT scan as core imaging modality to "clear" the cervical spine. The studies used two main gold standards, magnetic resonance imaging of the cervical spine and/or prolonged clinical follow-up. The data was extracted to report true positive, true negatives, false positives and false negatives. Meta-analysis of sensitivity, specificity, negative and positive predictive values was performed using Meta Analyst Beta 3.13 software. We also performed a retrospective investigation comparing a robust clinical follow-up and/or cervical spine MR findings in 53 obtunded blunt trauma patients, who previously had undergone a normal multidetector CT scan of the cervical spine reported by a radiologist. A total of 10 studies involving 1850 obtunded blunt trauma patients with initial cervical spine CT scan reported as normal were included in the final meta-analysis. The cumulative negative predictive value and specificity of cervical spine CT of the ten studies was 99.7% (99.4-99.9%, 95% confidence interval). The positive predictive value and sensitivity was 93.7% (84.0-97.7%, 95% confidence interval). In the retrospective review of our obtunded blunt trauma patients, none was later diagnosed to have significant cervical spine injury that required a change in clinical management. In a blunt trauma patient with altered sensorium, a normal cervical spine CT scan is conclusive to safely rule out a clinically

  18. Multi-detector CT-colonography in inflammatory bowel disease: Prospective analysis of CT-findings to high-resolution video colonoscopy

    International Nuclear Information System (INIS)

    Andersen, Kjel; Vogt, Christoph; Blondin, Dirk; Beck, Andreas; Heinen, Wolfram; Aurich, Volker; Haeussinger, Dieter; Moedder, Ulrich; Cohnen, Mathias

    2006-01-01

    Aim: Prospective analysis of multi-detector CT-colonography (MDCTC) in patients with inflammatory bowel disease (IBD) compared to high-resolution video-endoscopy (HRVC). Materials and methods: Twenty-one patients (mean age 49.6 years) with Crohn's disease or ulcerative colitis underwent MDCTC (Somatom Volume Zoom, Siemens, Erlangen; 1 mm collimation, Pitch 8, 100 mAs, 120 kVp). HRVC was performed within 2 h after MDCTC. MDCTC was analyzed by two blinded readers. MDCTC-findings including bowel wall alterations and extraintestinal changes were compared to results of HRVC. Results: Over-all-sensitivity was 100% for endoluminal lesions with correct diagnosis of two cancers. Acute and chronic IBD were correctly identified by MDCTC in 63.6%, and 100%, respectively, with a specificity of 75%, and 100%. Sensitivity, specificity, positive and negative predictive values of MDCTC for diagnosis of acute and chronic disease were best for chronic disease. Sensitivity was worst for acute ulcerative colitis and specificity was worst for acute Crohn's disease. Haustral loss was seen only in ulcerative colitis. Pseudopolyps and fistulae were findings exclusive to Crohn's disease. Particularly extraintestinal findings as increased vascularization and local lymphadenopathy correlated well with endoscopic definition of acute disease. Because of the possibly more vulnerable colonic wall in acute inflammatory bowel disease, the air inflation for MDCTC should be performed most carefully to avoid any risk of colonic perforation. Conclusion: MDCTC may help to distinguish between patients with acute and chronic IBD. Especially extraintestinal complications, tumorous as well as pseudo-tumorous lesions can be detected with high sensitivity and specificity

  19. Automatic exposure control in pediatric and adult multidetector CT examinations: A phantom study on dose reduction and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Papadakis, Antonios E.; Perisinakis, Kostas; Damilakis, John [Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 1352, Iraklion 71110, Crete (Greece)

    2008-10-15

    The aim of this study was to assess the potential of a modern x,y,z modulation-based automatic exposure control system (AEC) for dose reduction in pediatric and adult multidetector CT (MDCT) imaging and evaluate the quality of the images obtained. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-, 5-, 10-year old child, and adult were scanned with a MDCT scanner, equipped with a modern AEC system. Dose reduction (%DR) was calculated as the percentage difference of the mean modulated and the preset tube current-time product that is prescribed for standard head and body scan protocols. The effect of the tube potential and the orientation of the topogram acquisition on dose reduction were assessed. Image quality was evaluated on the basis of image noise and signal to noise ratio (SNR). The dose reduction values achieved in pediatric phantoms were remarkably lower than those achieved for the adult. The efficiency of the AEC is decreased at 80 kVp compared to higher tube potentials and for helical scans following an anterior posterior (AP-AEC) compared to a lateral (LAT-AEC) topogram acquisition. In AP-AEC scans, the dose reduction ranged between 4.7 and 34.7% for neonate, 15.4 and 30.9% for 1 year old, 3.1 and 26.7% for 5 years old, 1.2 and 58.7% for 10 years old, and 15.5 and 57.4% for adult. In LAT-AEC scans, the corresponding dose reduction ranged between 11.0 and 36.5%, 27.2 and 35.7%, 11.3 and 35.6%, 0.3 and 67.0%, and 15.0 and 61.7%, respectively. AP-AEC scans resulted in a 17.1% and 19.7% dose increase in the thorax of neonate and the pelvis of the 10-year old phantom, respectively. The variation in the measured noise among images obtained along the scanning z axis was lower in AEC activated compared to fixed milliamperes scans. However, image noise was significantly increased (P<.001) and SNR significantly decreased (P<.001) in most AEC activated compared to fixed milliamperes scans. In conclusion, AEC resulted in a (i

  20. Contribution of multi-detector row CT (MDCT) to decision making in the management of patients with small bowel obstruction or ileus

    International Nuclear Information System (INIS)

    Osada, Hisato; Watanabe, Wataru; Okada, Taketomo

    2007-01-01

    We retrospectively evaluated the contribution of multi-detector row CT (MDCT) to patient management decisions in 62 patients with small bowel obstruction or ileus. The sensitivity and specificity of MDCT diagnosis of small bowel obstruction with strangulation or closed loop were 78.9% (15/19) and 93.0% (40/43), respectively. In 19 patients with small bowel obstruction with strangulation or closed loop, the median interval between CT examination and the commencement of surgery was significantly longer in misdiagnosed patients than in those correctly diagnosed (43.3 vs. 4.5 hours, p<0.05). Only two patients displayed severe physical signs that required urgent surgical treatment. Our results suggest that MDCT plays a key role in the management of patients with small bowel obstruction. (author)

  1. Assessment of vertebral artery stents using 16-slice multi-detector row CT angiography in vivo evaluation: Comparison of a medium-smooth kernel and a sharp kernel

    International Nuclear Information System (INIS)

    Yoo, Won Jong; Lim, Yeon Soo; Ahn, Kook Jin; Choi, Byung Gil; Kim, Ji Young; Kim, Sung Hoon

    2009-01-01

    Objectives: To assess the lumen visibility of extracranial vertebral artery stents examined with 16-slice multi-detector row computed tomography (MDCT) angiography in vivo using a medium-smooth kernel (B30s) and a sharp kernel (B60s), and to compare these with digital subtraction angiography (DSA) after stent placement. Methods: Twenty stents from 20 patients (14 men, 6 women; mean age, 62.7 ± 10.1 years) who underwent CT angiography (CTA) with 16-slice MDCT were retrospectively analyzed. In CT angiograms using a B30s and a B60s, the lumen diameters and CT attenuations of the stented vessels were measured three times by three observers, and artificial luminal narrowing (ALN) was calculated. To assess measurement reliability on CT angiograms, the intraclass correlation coefficient (ICC) was used. DSA served as the reference standard for the in-stent luminal measurements on CT angiography. The median interval between CT angiography and DSA was 1 day (range 1-10). Results: For interobserver reliability, intraclass correlation coefficients for the lumen diameters on CT angiograms with a B30s and a B60s were 0.90 and 0.96, respectively. The lumen diameters on CT angiograms using a B30s were consistently smaller than that on CT angiograms using a B60s (p < 0.01). The mean ALN was 37 ± 7% on CT angiograms using a B30s and 25 ± 9% on CT angiograms using a B60s. The mean CT attenuation in in-stent lumen was 347 ± 55 HU on CT angiograms using a B30s and 295 ± 46 HU on CT angiograms using a B60s. The ALN and CT attenuation within the stented vessels between CT angiograms using a B30s and a B60s was significant (p < 0.01). Conclusions: 16-slice MDCT using a sharp kernel allows good visualization of the stented vessels and is useful in the assessment of vertebral artery stent patency after stent placement.

  2. Can use of adaptive statistical iterative reconstruction reduce radiation dose in unenhanced head CT? An analysis of qualitative and quantitative image quality

    International Nuclear Information System (INIS)

    Østerås, Bjørn Helge; Heggen, Kristin Livelten; Pedersen, Hans Kristian; Andersen, Hilde Kjernlie; Martinsen, Anne Catrine T

    2016-01-01

    Iterative reconstruction can reduce image noise and thereby facilitate dose reduction. To evaluate qualitative and quantitative image quality for full dose and dose reduced head computed tomography (CT) protocols reconstructed using filtered back projection (FBP) and adaptive statistical iterative reconstruction (ASIR). Fourteen patients undergoing follow-up head CT were included. All patients underwent full dose (FD) exam and subsequent 15% dose reduced (DR) exam, reconstructed using FBP and 30% ASIR. Qualitative image quality was assessed using visual grading characteristics. Quantitative image quality was assessed using ROI measurements in cerebrospinal fluid (CSF), white matter, peripheral and central gray matter. Additionally, quantitative image quality was measured in Catphan and vendor’s water phantom. There was no significant difference in qualitative image quality between FD FBP and DR ASIR. Comparing same scan FBP versus ASIR, a noise reduction of 28.6% in CSF and between −3.7 and 3.5% in brain parenchyma was observed. Comparing FD FBP versus DR ASIR, a noise reduction of 25.7% in CSF, and −7.5 and 6.3% in brain parenchyma was observed. Image contrast increased in ASIR reconstructions. Contrast-to-noise ratio was improved in DR ASIR compared to FD FBP. In phantoms, noise reduction was in the range of 3 to 28% with image content. There was no significant difference in qualitative image quality between full dose FBP and dose reduced ASIR. CNR improved in DR ASIR compared to FD FBP mostly due to increased contrast, not reduced noise. Therefore, we recommend using caution if reducing dose and applying ASIR to maintain image quality

  3. Calcium scoring in unenhanced and enhanced CT data of the aorta-iliacal arteries: impact of image acquisition, reconstruction, and analysis parameter settings

    Energy Technology Data Exchange (ETDEWEB)

    Komen, N. (Dept. of Surgery, Univ. Medical Center Rotterdam, Erasmus MC, Rotterdam (Netherlands); Dept. of Surgery, Univ. Hospital Antwerp, Edegem (Belgium)), email: nielskomen@hotmail.com; Klitsie, P.; Jeekel, J.; Lange, J.F. (Dept. of Surgery, Univ. Medical Center Rotterdam, Erasmus MC, Rotterdam (Netherlands)); Hermans, J.J.; Niessen, W.J. (Dept. of Radiology, Univ. Medical Center Rotterdam, Erasmus MC, Rotterdam (Netherlands)); Kleinrensink, G.J. (Dept. of Neurosciences and Anatomy, Univ. Medical Center Rotterdam, Erasmus MC, Rotterdam (Netherlands))

    2011-11-15

    Background. Several studies have been published on the matter of abdominal aortic and iliac calcifications and the association to clinical entities such as diabetes mellitus and renal failure. However, comparing of these studies is questionable since quantification methods for atherosclerosis differ. Purpose. To evaluate the effect of image acquisition settings, reconstruction parameters, and analysis methods on calcium quantification in the abdominal aorta. Material and Methods. Calcium scores were retrospectively determined on standardized abdominal CT scans of 15 patients. Two researchers obtained calcium scores with 10 different lower thresholds (LT) (130, 145, 160, 175, 200, 300, 400, 500, 600, 1000) in CT scans with and without contrast enhancement, with slice thicknesses (ST) varying between 2.0-5.0 mm for the non-contrast-enhanced series and between 1.0-5.0 mm for the contrast-enhanced series. In addition calcium scores obtained with two convolution kernels (B10f, B20f) were compared. Inter-observer variability was calculated. Results. Calcium scoring at higher STs is overestimated compared to smaller STs and this effect was more pronounced with increasing calcium loads. Concerning the convolution kernel, scores obtained with kernel B10f were overestimated compared to kernel B20f. Increase of LT resulted in a decrease of the calcium score and scoring in contrast-enhanced series resulted in higher scores compared to non-contrast-enhanced series. These effects are more apparent in patients with higher calcium loads. Calcium scoring reproducibility with the reference standard is limited for the aorta-iliac trajectory, whereas scoring with the remaining settings is reproducible. Conclusion. Scores obtained with different settings cannot be compared. The inter-observer reproducibility was limited using the reference standard and practical difficulties were substantial. Scoring with higher LT, ST, and contrast enhancement is faster and has less practical

  4. Multidetector CT Assessment of Lymph Node Size for Nodal Staging in Patients with Potentially Operable Squamous Esophageal Cancer and the 18F-FDG Positron Emission Tomography CT Correlation

    International Nuclear Information System (INIS)

    Yoom, Soo Kyung; Jung, Jung Im; Ahn, Myeong Im; Park, Jae Gil; Yoo, Ie Ryung; Park, Seog Hee; Park, Mi Jung; Park, Hyun Jin

    2010-01-01

    To investigate the size criteria of multidetector computed tomography (MDCT) for the evaluation metastatic lymph nodes (LNs) for potentially operable squamous esophageal cancer, and to compare this information with the results of positron emission tomography-CT (PET-CT). Twenty-four patients who underwent radical esophagectomy for esophageal cancer were studied. All patients had preoperative MDCT and PET-CT. The MDCT findings were compared with those of PET-CT and were correlated with the surgical records. The receiver operating characteristic (ROC) curve method was used to determine the appropriate cut-off value to distinguish benign from metastatic LNs. The size of metastatic LNs (9.35 ± 3.41 mm) was significantly larger than that of benign LNs (5.74 ± 1.64 mm) (p<0.001). The best cut-off value was 7 mm (81.8% sensitivity, 80.8% specificity). PET-CT detected all metastatic LNs except for four in the peritumoral region. The sensitivity and specificity of metastatic LN evaluation on PET-CT were 82.6% and 99.4%, respectively. Only one LN without metastasis showed increased fluoro-2-deoxy-D-glucose uptake on PET-CT. Size of metastatic LNs can typically be < 10 mm. For MDCT, the short diameter of 7 mm may be the optimal criterion. PET-CT is very accurate for the assessment of metastatic LNs except for those in the peritumoral region

  5. Imaging of Herniated Discs of the Cervical Spine: Inter-Modality Differences between 64-Slice Multidetector CT and 1.5-T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Yi, Ji Sook; Cha, Jang Gyu [Dept. of Radiology, Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Han, Jong Kyu [Dept. of Radiology, Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of); Kim, Hyun Joo [Dept. of Radiology, Soonchunhyang University Seoul Hospital, Seoul (Korea, Republic of)

    2015-08-15

    To assess inter-modality variability when evaluating cervical intervertebral disc herniation using 64-slice multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI). Three musculoskeletal radiologists independently reviewed cervical spine 1.5-T MRI and 64-slice MDCT data on C2-3 though C6-7 of 51 patients in the context of intervertebral disc herniation. Interobserver and inter-modality agreements were expressed as unweighted kappa values. Weighted kappa statistics were used to assess the extents of agreement in terms of the number of involved segments (NIS) in disc herniation and epicenter measurements collected using MDCT and MRI. The interobserver agreement rates upon evaluation of disc morphology by the three radiologists were in fair to moderate agreement (k = 0.39-0.53 for MDCT images; k = 0.45-0.56 for MRIs). When the disc morphology was categorized into two and four grades, the inter-modality agreement rates were moderate (k-value, 0.59) and substantial (k-value, 0.66), respectively. The inter-modality agreements for evaluations of the NIS (k-value, 0.78) and the epicenter (k-value, 0.79) were substantial. Also, the interobserver agreements for the NIS (CT; k-value, 0.85 and MRI; k-value, 0.88) and epicenter (CT; k-value, 0.74 and MRI; k-value, 0.70) evaluations by two readers were substantial. MDCT tended to underestimate the extent of herniated disc lesions compared with MRI. Multidetector-row computed tomography and MRI showed a moderate-to-substantial degree of inter-modality agreement for the assessment of herniated cervical discs. MDCT images have a tendency to underestimate the anterior/posterior extent of the herniated disc compared with MRI.

  6. Single-source dual-energy spectral multidetector CT of pancreatic adenocarcinoma: Optimization of energy level viewing significantly increases lesion contrast

    International Nuclear Information System (INIS)

    Patel, B.N.; Thomas, J.V.; Lockhart, M.E.; Berland, L.L.; Morgan, D.E.

    2013-01-01

    Aim: To evaluate lesion contrast in pancreatic adenocarcinoma patients using spectral multidetector computed tomography (MDCT) analysis. Materials and methods: The present institutional review board-approved, Health Insurance Portability and Accountability Act of 1996 (HIPAA)-compliant retrospective study evaluated 64 consecutive adults with pancreatic adenocarcinoma examined using a standardized, multiphasic protocol on a single-source, dual-energy MDCT system. Pancreatic phase images (35 s) were acquired in dual-energy mode; unenhanced and portal venous phases used standard MDCT. Lesion contrast was evaluated on an independent workstation using dual-energy analysis software, comparing tumour to non-tumoural pancreas attenuation (HU) differences and tumour diameter at three energy levels: 70 keV; individual subject-optimized viewing energy level (based on the maximum contrast-to-noise ratio, CNR); and 45 keV. The image noise was measured for the same three energies. Differences in lesion contrast, diameter, and noise between the different energy levels were analysed using analysis of variance (ANOVA). Quantitative differences in contrast gain between 70 keV and CNR-optimized viewing energies, and between CNR-optimized and 45 keV were compared using the paired t-test. Results: Thirty-four women and 30 men (mean age 68 years) had a mean tumour diameter of 3.6 cm. The median optimized energy level was 50 keV (range 40–77). The mean ± SD lesion contrast values (non-tumoural pancreas – tumour attenuation) were: 57 ± 29, 115 ± 70, and 146 ± 74 HU (p = 0.0005); the lengths of the tumours were: 3.6, 3.3, and 3.1 cm, respectively (p = 0.026); and the contrast to noise ratios were: 24 ± 7, 39 ± 12, and 59 ± 17 (p = 0.0005) for 70 keV, the optimized energy level, and 45 keV, respectively. For individuals, the mean ± SD contrast gain from 70 keV to the optimized energy level was 59 ± 45 HU; and the mean ± SD contrast gain from the optimized energy level to 45 ke

  7. Single-source dual-energy spectral multidetector CT of pancreatic adenocarcinoma: optimization of energy level viewing significantly increases lesion contrast.

    Science.gov (United States)

    Patel, B N; Thomas, J V; Lockhart, M E; Berland, L L; Morgan, D E

    2013-02-01

    To evaluate lesion contrast in pancreatic adenocarcinoma patients using spectral multidetector computed tomography (MDCT) analysis. The present institutional review board-approved, Health Insurance Portability and Accountability Act of 1996 (HIPAA)-compliant retrospective study evaluated 64 consecutive adults with pancreatic adenocarcinoma examined using a standardized, multiphasic protocol on a single-source, dual-energy MDCT system. Pancreatic phase images (35 s) were acquired in dual-energy mode; unenhanced and portal venous phases used standard MDCT. Lesion contrast was evaluated on an independent workstation using dual-energy analysis software, comparing tumour to non-tumoural pancreas attenuation (HU) differences and tumour diameter at three energy levels: 70 keV; individual subject-optimized viewing energy level (based on the maximum contrast-to-noise ratio, CNR); and 45 keV. The image noise was measured for the same three energies. Differences in lesion contrast, diameter, and noise between the different energy levels were analysed using analysis of variance (ANOVA). Quantitative differences in contrast gain between 70 keV and CNR-optimized viewing energies, and between CNR-optimized and 45 keV were compared using the paired t-test. Thirty-four women and 30 men (mean age 68 years) had a mean tumour diameter of 3.6 cm. The median optimized energy level was 50 keV (range 40-77). The mean ± SD lesion contrast values (non-tumoural pancreas - tumour attenuation) were: 57 ± 29, 115 ± 70, and 146 ± 74 HU (p = 0.0005); the lengths of the tumours were: 3.6, 3.3, and 3.1 cm, respectively (p = 0.026); and the contrast to noise ratios were: 24 ± 7, 39 ± 12, and 59 ± 17 (p = 0.0005) for 70 keV, the optimized energy level, and 45 keV, respectively. For individuals, the mean ± SD contrast gain from 70 keV to the optimized energy level was 59 ± 45 HU; and the mean ± SD contrast gain from the optimized energy level to 45 keV was 31 ± 25 HU (p = 0

  8. Evaluation of retrospectively ECG-gated 4-row multidetector CT in patients planned for minimal invasive coronary artery bypass grafting; Die EKG-getriggerte 4-Zeilen-Spiral-CT des Herzens in der praeoperativen Bildgebung vor minimalinvasiver koronarer Bypass-Operation

    Energy Technology Data Exchange (ETDEWEB)

    Begemann, P.G.C.; Ittrich, H.; Koops, A.; Adam, G.; Weber, C. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Radiologisches Zentrum, Universitaetsklinikum, Hamburg (Germany); Arnold, M.; Detter, C.; Boehm, D.H.; Reichenspurner, H. [Universitaetsklinikum Hamburg-Eppendorf, Herzzentrum, Herz und Gefaesschirurgie, Hamburg (Germany)

    2005-08-01

    Purpose: Minimal invasive direct coronary artery bypass grafting (MIDCAB) or off-pump coronary artery bypass grafting (OPCAB) on the beating heart with full or mini-sternotomy are becoming more common in coronary bypass surgery of the left anterior descending (LAD). In the decision, which surgical approach (MIDCAB, OPCAB or conventional surgery with cardiopulmonary bypass) will be best used, knowledge of the anatomical field is of major importance. The aim of the study was to evaluate retrospective ECG-gated 4-row multidetector CT (MDCT) in patients planned for MIDCAB as additional imaging to coronary angiography. Material and methods: The study included 25 consecutive patients. MSCT was performed as unenhanced (collimation 4 x 2.5 mm) and contrast-enhanced examination (140-170 ml, 300 mg Iodine/ml, collimation 4 x 1 mm). The evaluation included presence of LAD calcifications, distance of LAD and left internal mammarian artery (LIMA), coursek of LAD and LIMA, the presence or absence of bridging through myocardium or epicardial fat and the presence of pleural fibrosis. The MDCT results were correlated with intra-operative findings. Results: All MDCTs could be assessed with reference to the demands. In 20/25 operations, MDCT had direct influence as to the selection of the surgical approach (11 MIDCAB, 7 OPCAB with mini-sternotomy and 5 with full sternotomy, 2 conventional surgeries). The distance of LAD and LIMA varied from 0.9 to 4.5 cm in MDCT. As to calcifications, 3/25 correlated patients had calcifications and 10 patients had no calcifications in the middle LAD. Seven patients had intraoperative fibrosis of the vessel wall without calcification of the middle LAD, which could not be detected with MDCT. Another 5 patients had single calcified plaques in the middle LAD, 4 of these had a fibrosis of the vessel and 1 had a normal vessel at surgery. In these cases, the anastomosis was done between the calcified plaques. No myocardial bridging was detected by MDCT and

  9. Assessment of coronary artery aneurysms in paediatric patients with Kawasaki disease by multidetector row CT angiography: feasibility and comparison with 2D echocardiography

    International Nuclear Information System (INIS)

    Chu, W.C.W.; Lam, W.W.M.; Mok, G.C.F.; Yam, M.; Sung, R.Y.T.

    2006-01-01

    Transthoracic ECHO is the locally accepted method for coronary surveillance of patients with Kawasaki disease but it may have limited visualization in the older child. To assess the feasibility of multidetector CT (MDCT) angiography in the follow-up of coronary artery aneurysms in children with previous Kawasaki disease. Six children (5 boys, 1 girl; mean age 11.5 years) with known Kawasaki disease and coronary artery involvement underwent CT coronary angiography using 16-detector MDCT. The visualized lengths and diameter of all coronary segments were measured. The number, size and location of coronary artery aneurysms were recorded and compared with recent ECHO. Twelve coronary artery aneurysms (seven saccular, five fusiform) were identified by MDCT angiography. One saccular aneurysm at the junction of the distal right coronary artery and posterior descending artery was not detected by ECHO while the remaining six in proximal segments were detected by both modalities. Two of five fusiform aneurysms were not detected by ECHO due to their small sizes. Excellent agreement was found between CT and ECHO for maximal diameter and length of the visualized aneurysms. MDCT angiography accurately defines coronary artery aneurysms. It is more sensitive for detecting aneurysms at distal coronary segments and fusiform aneurysms of small size

  10. Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Xueqian; Zhao, Yingru; Ooijen, Peter M.A. van; Vliegenthart, Rozemarijn [University of Groningen, University Medical Center Groningen, Department of Radiology, EB44, P.O. Box 30.001, Groningen (Netherlands); University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Department of Radiology, Groningen (Netherlands); Snijder, Roland A.; Greuter, Marcel J.W. [University of Groningen, University Medical Center Groningen, Department of Radiology, EB44, P.O. Box 30.001, Groningen (Netherlands); Jong, Pim A. de [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Oudkerk, Matthijs [University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Department of Radiology, Groningen (Netherlands); Bock, Geertruida H. de [University of Groningen, University Medical Center Groningen, Department of Epidemiology, Groningen (Netherlands)

    2013-01-15

    To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -800, -630 and +100 HU) were randomly placed inside an anthropomorphic thoracic phantom. The phantom was examined on 16- and 64-row multidetector CT with a low-dose protocol. Two independent blinded observers screened for pulmonary nodules. Nodule diameter was measured manually, and volume calculated. For solid nodules (+100 HU), diameter and volume were also evaluated by semi-automated software. Differences in observed volumes between the manual and semi-automated method were evaluated by a t-test. Sensitivity was 100 % for all nodules of >5 mm and larger, 60-80 % for solid and 0-20 % for non-solid 3-mm nodules. No false-positive nodules but high inter-observer reliability and inter-technique correlation were found. Volume was underestimated manually by 24.1 {+-} 14.0 % for nodules of any density, and 26.4 {+-} 15.5 % for solid nodules, compared with 7.6 {+-} 8.5 % (P < 0.01) semi-automatically. In an anthropomorphic phantom study, the sensitivity of detection is 100 % for nodules of >5 mm in diameter. Semi-automated volumetry yielded more accurate nodule volumes than manual measurements. (orig.)

  11. Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study

    International Nuclear Information System (INIS)

    Xie, Xueqian; Zhao, Yingru; Ooijen, Peter M.A. van; Vliegenthart, Rozemarijn; Snijder, Roland A.; Greuter, Marcel J.W.; Jong, Pim A. de; Oudkerk, Matthijs; Bock, Geertruida H. de

    2013-01-01

    To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -800, -630 and +100 HU) were randomly placed inside an anthropomorphic thoracic phantom. The phantom was examined on 16- and 64-row multidetector CT with a low-dose protocol. Two independent blinded observers screened for pulmonary nodules. Nodule diameter was measured manually, and volume calculated. For solid nodules (+100 HU), diameter and volume were also evaluated by semi-automated software. Differences in observed volumes between the manual and semi-automated method were evaluated by a t-test. Sensitivity was 100 % for all nodules of >5 mm and larger, 60-80 % for solid and 0-20 % for non-solid 3-mm nodules. No false-positive nodules but high inter-observer reliability and inter-technique correlation were found. Volume was underestimated manually by 24.1 ± 14.0 % for nodules of any density, and 26.4 ± 15.5 % for solid nodules, compared with 7.6 ± 8.5 % (P 5 mm in diameter. Semi-automated volumetry yielded more accurate nodule volumes than manual measurements. (orig.)

  12. The role of multi-detector CT angiography in surgical planning for congenital cervicothoracic kyphoscoliosis: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun; Choi, Won Gyu; Shin, Ho Dong; Hwang, Byeong Wook; Lee, Sang Jin; Lee, Sang Ho [Busan Wooridul Spine Hospital, Busan (Korea, Republic of)

    2008-01-15

    Surgical correction of a cervicothoracic deformity is difficult with a potential risk of vascular injury. Comprehensive preoperative vascular evaluation is important for safe and successful surgery. The use of multi-detector computed tomography angiography (MDCTA) allows a combined display of vascular and osseous structures of the musculoskeletal system. However, no clinical reports have described the use of MDCTA for surgical planning of anterior cervicothoracic surgery in patients with vascular malformation. The case of a 7-year-old girl with congenital cervicothoracic kyphoscoliosis who underwent preoperative MDCTA evaluation and successful correction is presented in this report.

  13. Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with 15O-H2O PET

    International Nuclear Information System (INIS)

    Kikuchi, Yasuka; Oyama-Manabe, Noriko; Kudo, Kohsuke; Naya, Masanao; Manabe, Osamu; Tomiyama, Yuuki; Tamaki, Nagara; Sasaki, Tsukasa; Katoh, Chietsugu; Shirato, Hiroki

    2014-01-01

    This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against 15 O-H 2 O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). Correlation between MBF of MDCT and PET was strong (r = 0.95, P CT in the CAD group (2.3 ± 0.8) was significantly lower than that in the validation group (5.2 ± 1.8) (P = 0.0011). We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. (orig.)

  14. Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility

    International Nuclear Information System (INIS)

    Lee, Tain; Tsai, I.C.; Chen, Min-Chi; Fu, Yun-Ching; Jan, Sheng-Lin; Wang, Chung-Chi; Chang, Yen

    2006-01-01

    Echocardiography is the first-line modality for the investigation of neonatal congenital heart disease. Diagnostic cardiac catheterization, which has a small but recognized risk, is usually performed if echocardiography fails to provide a confident evaluation of the lesions. To verify the technical and clinical feasibilities of replacing diagnostic cardiac catheterization with multidetector-row CT (MDCT) in neonatal complex congenital heart disease. Over a 1-year period we prospectively enrolled all neonates with complex congenital heart disease referred for diagnostic cardiac catheterization after initial assessment by echocardiography. MDCT was performed using a 40-detector-row CT scanner with dual syringe injection. A multidisciplinary congenital heart disease team evaluated the MDCT images and decided if further diagnostic cardiac catheterization was necessary. The accuracy of MDCT in detecting separate cardiovascular anomalies and bolus geometry of contrast enhancement were calculated. A total of 14 neonates were included in the study. No further diagnostic cardiac catheterization was needed in any neonate. The accuracy of MDCT in diagnosing separate cardiovascular anomalies was 98% (53/54) with only one atrial septal defect missed in a patient with coarctation syndrome. The average cardiovascular enhancement in evaluated chambers was 471 HU. No obvious beam-hardening artefact was observed. The technical and clinical feasibility of MDCT in complex congenital heart disease in neonates is confirmed. After initial assessment with echocardiography, MDCT could probably replace diagnostic cardiac catheterization for further anatomical clarification in neonates. (orig.)

  15. Evaluation of the relationship between extremity soft tissue sarcomas and adjacent major vessels using contrast-enhanced multidetector CT and three-dimensional volume-rendered CT angiography - A preliminary study

    International Nuclear Information System (INIS)

    Li, YangKang; Lin, JianBang; Cai, AiQun; Zhou, XiuGuo; Zheng, Yu; Wei, XiaoLong; Cheng, Ying; Liu, GuoRui

    2013-01-01

    Background: Accurate description of the relationship between extremity soft tissue sarcoma and the adjacent major vessels is crucial for successful surgery. In addition to magnetic resonance imaging (MRI) or in patients who cannot undergo MRI, two-dimensional (2D) postcontrast computed tomography (CT) images and three-dimensional (3D) volume-rendered CT angiography may be valuable alternative imaging techniques for preoperative evaluation of extremity sarcomas. Purpose: To preoperatively assess extremity sarcomas using multidetector CT (MDCT), with emphasis on postcontrast MDCT images and 3D volume-rendered MDCT angiography in evaluating the relationship between tumors and adjacent major vessels. Material and Methods: MDCT examinations were performed on 13 patients with non-metastatic extremity sarcomas. Conventional CT images and 3D volume-rendered CT angiography were evaluated, with focus on the relationship between tumors and adjacent major vessels. Kappa consistency statistics were performed with surgery serving as the reference standard. Results: The relationship between sarcomas and adjacent vessels was described as one of three patterns: proximity, adhesion, and encasement. Proximity was seen in five cases on postcontrast CT images or in eight cases on volume-rendered images. Adhesion was seen in three cases on both postcontrast CT images and volume-rendered images. Encasement was seen in five cases on postcontrast CT images or in two cases on volume-rendered images. Compared to surgical results, postcontrast CT images had 100% sensitivity, 83.3% specificity, 87.5% positive predictive value, 100% negative predictive value, and 92.3% accuracy in the detection of vascular invasion (κ = 0.843, P = 0.002). 3D volume-rendered CT angiography had 71.4% sensitivity, 100% specificity, 100% positive predictive value, 75% negative predictive value, and 84.6% accuracy in the detection of vascular invasion (κ = 0.698, P = 0.008). On volume-rendered images, all cases

  16. Iodine quantification to distinguish clear cell from papillary renal cell carcinoma at dual-energy multidetector CT: a multireader diagnostic performance study.

    Science.gov (United States)

    Mileto, Achille; Marin, Daniele; Alfaro-Cordoba, Marcela; Ramirez-Giraldo, Juan Carlos; Eusemann, Christian D; Scribano, Emanuele; Blandino, Alfredo; Mazziotti, Silvio; Ascenti, Giorgio

    2014-12-01

    To investigate whether dual-energy multidetector row computed tomographic (CT) imaging with iodine quantification is able to distinguish between clear cell and papillary renal cell carcinoma ( RCC renal cell carcinoma ) subtypes. In this retrospective, HIPAA-compliant, institutional review board-approved study, 88 patients (57 men, 31 women) with diagnosis of either clear cell or papillary RCC renal cell carcinoma at pathologic analysis, who underwent contrast material-enhanced dual-energy nephrographic phase study between December 2007 and June 2013, were included. Five readers, blinded to pathologic diagnosis, independently evaluated all cases by determining the lesion iodine concentration on color-coded iodine maps. The receiving operating characteristic curve analysis was adopted to estimate the optimal threshold for discriminating between clear cell and papillary RCC renal cell carcinoma , and results were validated by using a leave-one-out cross-validation. Interobserver agreement was assessed by using an intraclass correlation coefficient. The correlation between tumor iodine concentration and tumor grade was investigated. A tumor iodine concentration of 0.9 mg/mL represented the optimal threshold to discriminate between clear cell and papillary RCC renal cell carcinoma , and it yielded the following: sensitivity, 98.2% (987 of 1005 [95% confidence interval: 97.7%, 98.7%]); specificity, 86.3% (272 of 315 [95% confidence interval: 85.0%, 87.7%]); positive predictive value, 95.8% (987 of 1030 [95% confidence interval: 95.0%, 96.6%]); negative predictive value, 93.7% (272 of 290 [95% confidence interval: 92.8%, 94.7%]); overall accuracy of 95.3% (1259 of 1320 [95% confidence interval: 94.6%, 96.2%]), with an area under the curve of 0.923 (95% confidence interval: 0.913, 0.933). An excellent agreement was found among the five readers in measured tumor iodine concentration (intraclass correlation coefficient, 0.9990 [95% confidence interval: 0. 9987, 0.9993). A

  17. Paediatric multidetector CT optimisation training: a survey of common scanning procedures and the resultant dose reduction associated with paediatric MDCT investigations in Australia

    International Nuclear Information System (INIS)

    Wallace, Anthony; Sibelle, Kimberly; Stanley, Martin; Budd, Ray; Goergen, Stacey; Heggie, John

    2008-01-01

    The growing recognition of the increased risk of stochastic injury to paediatric patients from multidetector CT (MDCT) investigations prompted a survey sponsored by Royal Australian and New Zealand College of Radiology (RANZCR), Austin Health and Monash University to initiate a national paediatric dosimetry review for some of the most common investigations undertaken in MDCT paediatric practice. The survey forms included a data sheet requiring acquisition protocol parameters and a phantom graphic sheet requiring the marking of the inferior and superior acquisition margins. Survey forms were supplied for each of 13 common MDCT acquisitions to be tested. Response data was input into CT-Expo Version 1.5.1., a CT dosimetry calculation engine, to determine dose length product (DLP (mGy.cm)) and effective dose (ED (mSv)). Initial survey data was collected, calculated, blinded and collated into various presentations that were given at a MDCT optimisation seminar in November, 2006. All sites were re-surveyed in May 2007 and doses calculated. Initial survey data showed a range of dose efficiencies spread across the surveyed sites. A measure of the initial spread of DLP values per procedure ranged from a minimum of less than 2 for a head-trauma acquisition (372 - 520 mGy.cm) to 14 for a chest-trauma acquisition (28 - 388 mGy.cm). Results of the 2nd survey strongly indicate that the application of optimisation training to paediatric MDCT scanning can produce significant dose savings by the application of simple dose saving strategies. Many protocols demonstrated dose reductions of greater than 50% with significant reductions in both the maximum and minimum values of calculated DLP and ED. The development of a survey-training-resurvey model of MDCT optimisation has proven to be a successful strategy for paediatric MDCT dose reduction in Australia. (author)

  18. Intra-individual comparison of patient acceptability of multidetector-row CT colonography and double-contrast barium enema

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, S.A. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom)]. E-mail: csytaylor@yahoo.co.uk; Halligan, S. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Burling, D. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Bassett, P. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Bartram, C.I. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom)

    2005-02-01

    AIMS: To compare the subjective acceptability of CT colonography in comparison with barium enema in older symptomatic patients, and to ascertain preferences for future colonic investigation. MATERIALS AND METHODS: The study population comprised 78 persons aged 60 years or over with symptoms suggestive of colorectal neoplasia, who underwent CT colonography followed the same day by barium enema. A 25-point questionnaire was administered after each procedure and an additional follow-up questionnaire a week later. Responses were compared using Wilcoxon matched pairs testing, Mann-Whitney test statistics and binomial exact testing. RESULTS: Participants suffered less physical discomfort during CT colonography (p=0.03) and overall satisfaction was greater compared with barium enema (p=0.03). On follow-up, respondents reported significantly better tolerance of CT colonography (p=0.002), and were less prepared to undergo barium enema again (p<0.001). Of 52 subjects expressing an opinion, all preferred CT to barium enema. CONCLUSION: Patient satisfaction was higher with CT colonography than barium enema. CT colonography caused significantly less physical discomfort and was overwhelmingly preferred by patients.

  19. Intra-individual comparison of patient acceptability of multidetector-row CT colonography and double-contrast barium enema

    International Nuclear Information System (INIS)

    Taylor, S.A.; Halligan, S.; Burling, D.; Bassett, P.; Bartram, C.I.

    2005-01-01

    AIMS: To compare the subjective acceptability of CT colonography in comparison with barium enema in older symptomatic patients, and to ascertain preferences for future colonic investigation. MATERIALS AND METHODS: The study population comprised 78 persons aged 60 years or over with symptoms suggestive of colorectal neoplasia, who underwent CT colonography followed the same day by barium enema. A 25-point questionnaire was administered after each procedure and an additional follow-up questionnaire a week later. Responses were compared using Wilcoxon matched pairs testing, Mann-Whitney test statistics and binomial exact testing. RESULTS: Participants suffered less physical discomfort during CT colonography (p=0.03) and overall satisfaction was greater compared with barium enema (p=0.03). On follow-up, respondents reported significantly better tolerance of CT colonography (p=0.002), and were less prepared to undergo barium enema again (p<0.001). Of 52 subjects expressing an opinion, all preferred CT to barium enema. CONCLUSION: Patient satisfaction was higher with CT colonography than barium enema. CT colonography caused significantly less physical discomfort and was overwhelmingly preferred by patients

  20. The effects of emphysema on airway disease: Correlations between multi-detector CT and pulmonary function tests in smokers

    International Nuclear Information System (INIS)

    Yahaba, Misuzu; Kawata, Naoko; Iesato, Ken; Matsuura, Yukiko; Sugiura, Toshihiko; Kasai, Hajime; Sakurai, Yoriko; Terada, Jiro; Sakao, Seiichiro; Tada, Yuji; Tanabe, Nobuhiro; Tatsumi, Koichiro

    2014-01-01

    Background: Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation caused by emphysema and small airway narrowing. Quantitative evaluation of airway dimensions by multi-detector computed tomography (MDCT) has revealed a correlation between airway dimension and airflow limitation. However, the effect of emphysema on this correlation is unclear. Objective: The goal of this study was to determine whether emphysematous changes alter the relationships between airflow limitation and airway dimensions as measured by inspiratory and expiratory MDCT. Methods: Ninety-one subjects underwent inspiratory and expiratory MDCT. Images were evaluated for mean airway luminal area (Ai), wall area percentage (WA%) from the third to the fifth generation of three bronchi (B1, B5, B8) in the right lung, and low attenuation volume percent (LAV%). Correlations between each airway index and airflow limitation were determined for each patient and compared between patients with and without evidence of emphysema. Results: In patients without emphysema, Ai and WA% from both the inspiratory and expiratory scans were significantly correlated with FEV 1. No correlation was detected in patients with emphysema. In addition, emphysematous COPD patients with GOLD stage 1 or 2 disease had significantly lower changes in B8 Ai than non-emphysematous patients. Conclusions: A significant correlation exists between airway parameters and FEV 1 in patients without emphysema. Emphysema may influence airway dimensions even in patients with mild to moderate COPD

  1. Fusion of the midplane with the left intersectional plane: a liver anatomical variation revisited with multidetector-row CT

    International Nuclear Information System (INIS)

    Lucidarme, Olivier; Taboury, Jacques; Savier, Eric; Hannoun, Laurent; Cadi, Mehdi; Grenier, Philippe A.

    2006-01-01

    This article updates the description of an anatomical variation of the liver, in which the gallbladder is adjacent to the ligamentum teres, that was described until now as ''right-sided ligamentum teres and right umbilical portion of the portal vein''. A study of eight patients showing this anatomical variation has led to a new archetypal anatomical description of the hepatic and portal veins, using multidetector-row computed tomography (MDCT) with three-dimensional (3D) volume-rendering (VR) reconstructions. While 2D axial imaging gave the same information, MDCT imaging with VR reconstructions provided a clear 3D visualization of this anatomical variation. Typical features can be described as follows: (1) juxtaposition of the ligamentum teres and the gallbladder; (2) typical portal vein branching with a right posterior branch, a left posterior branch and a main medial branch that terminates in the ligamentum teres; (3) two main hepatic veins and a hypotrophied medial hepatic vein. We think, based on the direct comparison of anatomical findings and knowledge of chronological embryological development, that this abnormality results from the defective development of the central part of the liver and not from the persistence of the right rather than the left umbilical vein. Because of the presence of only one medial plane, containing both the gallbladder and the ligamentum teres, we propose renaming it ''fusion of hepatic planes''. (orig.)

  2. The effects of emphysema on airway disease: Correlations between multi-detector CT and pulmonary function tests in smokers

    Energy Technology Data Exchange (ETDEWEB)

    Yahaba, Misuzu, E-mail: mis_misuzu@yahoo.co.jp; Kawata, Naoko, E-mail: chumito_03@yahoo.co.jp; Iesato, Ken, E-mail: iesato_k@yahoo.co.jp; Matsuura, Yukiko, E-mail: matsuyuki_future@yahoo.co.jp; Sugiura, Toshihiko, E-mail: sugiura@js3.so-net.ne.jp; Kasai, Hajime, E-mail: daikasai6075@yahoo.co.jp; Sakurai, Yoriko, E-mail: yoliri@nifty.com; Terada, Jiro, E-mail: jirotera@chiba-u.jp; Sakao, Seiichiro, E-mail: sakao@faculty.chiba-u.jp; Tada, Yuji, E-mail: ytada@faculty.chiba-u.jp; Tanabe, Nobuhiro, E-mail: ntanabe@faculty.chiba-u.jp; Tatsumi, Koichiro, E-mail: tatsumi@faculty.chiba-u.jp

    2014-06-15

    Background: Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation caused by emphysema and small airway narrowing. Quantitative evaluation of airway dimensions by multi-detector computed tomography (MDCT) has revealed a correlation between airway dimension and airflow limitation. However, the effect of emphysema on this correlation is unclear. Objective: The goal of this study was to determine whether emphysematous changes alter the relationships between airflow limitation and airway dimensions as measured by inspiratory and expiratory MDCT. Methods: Ninety-one subjects underwent inspiratory and expiratory MDCT. Images were evaluated for mean airway luminal area (Ai), wall area percentage (WA%) from the third to the fifth generation of three bronchi (B1, B5, B8) in the right lung, and low attenuation volume percent (LAV%). Correlations between each airway index and airflow limitation were determined for each patient and compared between patients with and without evidence of emphysema. Results: In patients without emphysema, Ai and WA% from both the inspiratory and expiratory scans were significantly correlated with FEV{sub 1.} No correlation was detected in patients with emphysema. In addition, emphysematous COPD patients with GOLD stage 1 or 2 disease had significantly lower changes in B8 Ai than non-emphysematous patients. Conclusions: A significant correlation exists between airway parameters and FEV{sub 1} in patients without emphysema. Emphysema may influence airway dimensions even in patients with mild to moderate COPD.

  3. Mediastinal and hilar lymphadenopathy: cross-referenced anatomy on axial and coronal images displayed by using multi-detector row CT

    International Nuclear Information System (INIS)

    Lee, Ju Hyun; Lee, Kyung Soo; Kim, Tae Sung; Yi, Chin A; Cho, Jae Min; Lee, Min Hee

    2003-01-01

    The accurate evaluation of mediastinal and pulmonary hilar lymphadenopathy, especially in patients with lung cancer, is important for determining treatment options and evaluating the response to therapy. To indicate nodal location in detail, mediastinal and hilar lymph nodes have been assigned to one of 14 nodal stations. Mediastinal nodes of greater than 10 mm short-axis diameter are regarded as abnormal, irrespective of their nodal station, while hilar nodes are considered abnormal if their diameter is greater than 10 mm in any axis or they are convex compared to surrounding lung. By providing multiplanar images, multi-detector row CT allows detailed evaluation of thoracic anatomic structures more easily than in the past, when axial images only were available. At cross-referenced imaging, a lymph node depicted at axial imaging in one anatomical location can be visualized simultaneously and automatically at coronal imaging at the exactly corresponding anatomical location. Cross-referenced coincidental axial and coronal images help assess both the size and morphology of mediastinal and hilar lymph nodes

  4. Is multidetector CT-based bone mineral density and quantitative bone microstructure assessment at the spine still feasible using ultra-low tube current and sparse sampling?

    Energy Technology Data Exchange (ETDEWEB)

    Mei, Kai; Kopp, Felix K.; Schwaiger, Benedikt J.; Gersing, Alexandra S.; Sauter, Andreas; Muenzel, Daniela; Rummeny, Ernst J. [Klinikum rechts der Isar, Technische Universitaet Muenchen, Department of Diagnostic and Interventional Radiology, Munich (Germany); Bippus, Rolf [Research Laboratories, Philips GmbH Innovative Technologies, Hamburg (Germany); Koehler, Thomas [Research Laboratories, Philips GmbH Innovative Technologies, Hamburg (Germany); Technische Universitaet Muenchen, TUM Institute for Advanced Studies, Garching (Germany); Fehringer, Andreas [Technische Universitaet Muenchen, Lehrstuhl fuer Biomedizinische Physik, Garching (Germany); Pfeiffer, Franz [Klinikum rechts der Isar, Technische Universitaet Muenchen, Department of Diagnostic and Interventional Radiology, Munich (Germany); Technische Universitaet Muenchen, TUM Institute for Advanced Studies, Garching (Germany); Technische Universitaet Muenchen, Lehrstuhl fuer Biomedizinische Physik, Garching (Germany); Kirschke, Jan S. [Klinikum rechts der Isar, Technische Universitaet Muenchen, Section of Diagnostic and Interventional Neuroradiology, Munich (Germany); Noel, Peter B. [Klinikum rechts der Isar, Technische Universitaet Muenchen, Department of Diagnostic and Interventional Radiology, Munich (Germany); Technische Universitaet Muenchen, Lehrstuhl fuer Biomedizinische Physik, Garching (Germany); Baum, Thomas [Klinikum rechts der Isar, Technische Universitaet Muenchen, Department of Diagnostic and Interventional Radiology, Munich (Germany); Klinikum rechts der Isar, Technische Universitaet Muenchen, Section of Diagnostic and Interventional Neuroradiology, Munich (Germany)

    2017-12-15

    Osteoporosis diagnosis using multidetector CT (MDCT) is limited to relatively high radiation exposure. We investigated the effect of simulated ultra-low-dose protocols on in-vivo bone mineral density (BMD) and quantitative trabecular bone assessment. Institutional review board approval was obtained. Twelve subjects with osteoporotic vertebral fractures and 12 age- and gender-matched controls undergoing routine thoracic and abdominal MDCT were included (average effective dose: 10 mSv). Ultra-low radiation examinations were achieved by simulating lower tube currents and sparse samplings at 50%, 25% and 10% of the original dose. BMD and trabecular bone parameters were extracted in T10-L5. Except for BMD measurements in sparse sampling data, absolute values of all parameters derived from ultra-low-dose data were significantly different from those derived from original dose images (p<0.05). BMD, apparent bone fraction and trabecular thickness were still consistently lower in subjects with than in those without fractures (p<0.05). In ultra-low-dose scans, BMD and microstructure parameters were able to differentiate subjects with and without vertebral fractures, suggesting osteoporosis diagnosis is feasible. However, absolute values differed from original values. BMD from sparse sampling appeared to be more robust. This dose-dependency of parameters should be considered for future clinical use. (orig.)

  5. Retrospectively ECG-gated multi-detector row CT of the chest: does ECG-gating improve three-dimensional visualization of the bronchial tree?

    International Nuclear Information System (INIS)

    Schertler, T.; Wildermuth, S.; Willmann, J.K.; Crook, D.W.; Marincek, B.; Boehm, T.

    2004-01-01

    Purpose: To determine the impact of retrospectively ECG-gated multi-detector row CT (MDCT) on three-dimensional (3D) visualization of the bronchial tree and virtual bronchoscopy (VB) as compared to non-ECG-gated data acquisition. Materials and Methods: Contrast-enhanced retrospectively ECG-gated and non-ECG-gated MDCT of the chest was performed in 25 consecutive patients referred for assessment of coronary artery bypass grafts and pathology of the ascending aorta. ECG-gated MDCT data were reconstructed in diastole using an absolute reverse delay of -400 msec in all patients. In 10 patients additional reconstructions at -200 msec, -300 msec, and -500 msec prior to the R-wave were performed. Shaded surface display (SSD) and virtual bronchoscopy (VB) for visualization of the bronchial segments was performed with ECG-gated and non-ECG-gated MDCT data. The visualization of the bronchial tree underwent blinded scoring. Effective radiation dose and signal-to-noise ratio (SNR) for both techniques were compared. Results: There was no significant difference in visualizing single bronchial segments using ECG-gated compared to non-ECG-gated MDCT data. However, the total sum of scores for all bronchial segments visualized with non-ECG-gated MDCT was significantly higher compared to ECG-gated MDCT (P [de

  6. The role of three-dimensional multidetector CT gastrography in the preoperative imaging of stomach cancer: Emphasis on detection and localization of the tumor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Woong; Shin, Sang Soo; Heo, Suk Hee; Lim, Hyo Soon; Park, Young Kyu; Jeong, Yong Yeon; Kang, Heoung Keun [Chonnam National University Medical School, Gwangju (Korea, Republic of); Lim, Nam Yeol [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2015-02-15

    Multidetector CT (MDCT) gastrography has been regarded as a promising technique for the preoperative imaging of gastric cancer. It has the ability to produce various three-dimensional (3D) images. Because 3D reconstruction images are more effective and intuitive for recognizing abnormal changes in the gastric folds and subtle mucosal nodularity than two-dimensional images, 3D MDCT gastrography can enhance the detection rate of early gastric cancer, which, in turn, contributes to the improvement of the accuracy of preoperative tumor (T) staging. In addition, shaded surface display and tissue transition projection images provide a global view of the stomach, with the exact location of gastric cancer, which may replace the need for barium studies. In this article, we discuss technical factors in producing high-quality MDCT gastrographic images and present cases demonstrating the usefulness of MDCT gastrography for the detection and T staging of gastric cancer while emphasizing the significance of preoperative localization of gastric cancer in terms of surgical margin.

  7. Visualization of coronary arteries in patients after childhood Kawasaki syndrome: value of multidetector CT and MR imaging in comparison to conventional coronary catheterization

    International Nuclear Information System (INIS)

    Arnold, Raoul; Ley, Sebastian; Ley-Zaporozhan, Julia; Kauczor, Hans-Ulrich; Eichhorn, Joachim; Ulmer, Herbert; Schenk, Jens-Peter

    2007-01-01

    After childhood Kawasaki syndrome (KS) the coronary arteries undergo a lifelong dynamic pathological change, and follow-up coronary artery imaging is essential. At present, conventional coronary catheterization (CCC) and angiography is still regarded as the gold standard. Less-invasive methods such as multidetector CT angiography (MDCT-A) and MRI have been used sporadically. To compare the diagnostic quality of MDCT-A and MRI with that of CCC for coronary imaging in a group of patients with coronary artery pathology after childhood KS. A total of 16 patients (aged 5-27 years) underwent CCC and 16-row MDCT-A and 14 patients MRI (1.5 T). There was 100% agreement between MDCT-A and CCC in the detection of coronary aneurysms and stenoses. MDCT-A was superior for the visualization of calcified lesions. MRI and CCC showed 93% agreement for the detection of aneurysms. Visualization of coronary artery stenoses was difficult using MRI - one stenosis was missed. MDCT-A has excellent correlation with CCC regarding all changes affecting the coronary arteries in the follow-up of childhood KS. In comparison to MDCT-A and CCC, MRI is less precise in the detection of stenotic lesions. Due to its high image quality and ease of performance MDCT-A should be the primary diagnostic modality in patients following childhood KS. (orig.)

  8. Is multidetector CT-based bone mineral density and quantitative bone microstructure assessment at the spine still feasible using ultra-low tube current and sparse sampling?

    International Nuclear Information System (INIS)

    Mei, Kai; Kopp, Felix K.; Schwaiger, Benedikt J.; Gersing, Alexandra S.; Sauter, Andreas; Muenzel, Daniela; Rummeny, Ernst J.; Bippus, Rolf; Koehler, Thomas; Fehringer, Andreas; Pfeiffer, Franz; Kirschke, Jan S.; Noel, Peter B.; Baum, Thomas

    2017-01-01

    Osteoporosis diagnosis using multidetector CT (MDCT) is limited to relatively high radiation exposure. We investigated the effect of simulated ultra-low-dose protocols on in-vivo bone mineral density (BMD) and quantitative trabecular bone assessment. Institutional review board approval was obtained. Twelve subjects with osteoporotic vertebral fractures and 12 age- and gender-matched controls undergoing routine thoracic and abdominal MDCT were included (average effective dose: 10 mSv). Ultra-low radiation examinations were achieved by simulating lower tube currents and sparse samplings at 50%, 25% and 10% of the original dose. BMD and trabecular bone parameters were extracted in T10-L5. Except for BMD measurements in sparse sampling data, absolute values of all parameters derived from ultra-low-dose data were significantly different from those derived from original dose images (p<0.05). BMD, apparent bone fraction and trabecular thickness were still consistently lower in subjects with than in those without fractures (p<0.05). In ultra-low-dose scans, BMD and microstructure parameters were able to differentiate subjects with and without vertebral fractures, suggesting osteoporosis diagnosis is feasible. However, absolute values differed from original values. BMD from sparse sampling appeared to be more robust. This dose-dependency of parameters should be considered for future clinical use. (orig.)

  9. Multi-Detector CT Findings of the Normal Appendix in Children: Evaluation of the Position, Diameter, and Presence or Absence of Intraluminal Gas

    Energy Technology Data Exchange (ETDEWEB)

    Park, Woon Ju; Kim, Jong Chul [Dept. of Radiology, Chungnam National University College of Medicine, Daejeon (Korea, Republic of)

    2011-08-15

    To assess the usefulness of multi-detector CT (MDCT) with multiplanar reformations (MPR) for the evaluation of the position, diameter and presence or absence of intraluminal gas in the normal appendix in children. From 2007 to 2010, we retrospectively analyzed the MDCT images of normal appendices in 133 children, and evaluated the position, diameter, and presence or absence of intraluminal gas in the appendix. Among the 133 appendices, type I (postileal and medial paracecal position) was found in 64 children, type II (subcecal position) in 22, type III (retrocecal and retrocolic/laterocolic position) in 15, type IV (preileal and medial colic position) in 16, and type V (lower pelvic position) in 16 children. The mean diameter was 5.8 mm {+-} 1.2 (SD) (range; 3.2-8.7 mm). There was a high correlation between the appendiceal diameter and age (p = 0.000).There was no statistically significant difference in the appendiceal diameter between boys and girls (p = 0.470). Intraluminal gas was found in 115 appendices and there was no statistically significant correlation between the appendiceal diameter and intraluminal gas (p = 0.502). The MDCT with MPR was useful for the evaluation of the normal appendices in children. The procedure may be useful for the diagnosis of equivocal or unusual appendicitis in children.

  10. Spontaneous obliteration of right ventricular pseudoaneurysm after blunt chest trauma: Diagnosis and follow-up with multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Tae Kyung; Kang, Mi Jin; Kim, Jae Hyung [Sanggye Paik Hospital, Inje University College of Medicine, Seoul (Korea, Republic of)

    2014-06-15

    Right ventricular (RV) pseudoaneurysm caused by trauma is very rare. We report a case of RV pseudoaneurysm which resolved without surgical treatment in a patient who survived a falling accident. Echocardiography failed to identify the pseudoaneurysm. Electrocardiography-gated CT showed a 17-mm-sized saccular pseusoaneurysm arsing from the RV outflow tract with a narrow neck. Follow-up CT after two months showed spontaneous obliteration of the lesion.

  11. Evaluation of living liver donors using contrast enhanced multidetector CT – The radiologists impact on donor selection

    Directory of Open Access Journals (Sweden)

    Ringe Kristina

    2012-07-01

    Full Text Available Abstract Background Living donor liver transplantation (LDLT is a valuable and legitimate treatment for patients with end-stage liver disease. Computed tomography (CT has proven to be an important tool in the process of donor evaluation. The purpose of this study was to evaluate the significance of CT in the donor selection process. Methods Between May 1999 and October 2010 170 candidate donors underwent biphasic CT. We retrospectively reviewed the results of the CT and liver volumetry, and assessed reasons for rejection. Results 89 candidates underwent partial liver resection (52.4%. Based on the results of liver CT and volumetry 22 candidates were excluded as donors (31% of the cases. Reasons included fatty liver (n = 9, vascular anatomical variants (n = 4, incidental finding of hemangioma and focal nodular hyperplasia (n = 1 and small (n = 5 or large for size (n = 5 graft volume. Conclusion CT based imaging of the liver in combination with dedicated software plays a key role in the process of evaluation of candidates for LDLT. It may account for up to 1/3 of the contraindications for LDLT.

  12. Evaluation of living liver donors using contrast enhanced multidetector CT – The radiologists impact on donor selection

    International Nuclear Information System (INIS)

    Ringe, Kristina Imeen; Ringe, Bastian Paul; Falck, Christian von; Shin, Hoen-oh; Becker, Thomas; Pfister, Eva-Doreen; Wacker, Frank; Ringe, Burckhardt

    2012-01-01

    Living donor liver transplantation (LDLT) is a valuable and legitimate treatment for patients with end-stage liver disease. Computed tomography (CT) has proven to be an important tool in the process of donor evaluation. The purpose of this study was to evaluate the significance of CT in the donor selection process. Between May 1999 and October 2010 170 candidate donors underwent biphasic CT. We retrospectively reviewed the results of the CT and liver volumetry, and assessed reasons for rejection. 89 candidates underwent partial liver resection (52.4%). Based on the results of liver CT and volumetry 22 candidates were excluded as donors (31% of the cases). Reasons included fatty liver (n = 9), vascular anatomical variants (n = 4), incidental finding of hemangioma and focal nodular hyperplasia (n = 1) and small (n = 5) or large for size (n = 5) graft volume. CT based imaging of the liver in combination with dedicated software plays a key role in the process of evaluation of candidates for LDLT. It may account for up to 1/3 of the contraindications for LDLT

  13. 64-Slice multidetector row CT angiography of the abdomen: comparison of low versus high concentration iodinated contrast media in a porcine model

    Science.gov (United States)

    Holalkere, N-S; Matthes, K; Kalva, S P; Brugge, W R; Sahani, D V

    2011-01-01

    Objective In this study we aimed to assess the image quality and degree of vascular enhancement using low-concentration contrast media (LCCM) (300 mg I ml–1) and high-concentration contrast media (HCCM) (370 mg I ml–1) on 64-slice multidetector row CT (MDCT) abdominal CT angiography (CTA). In addition, we aimed to study the feasibility of using HCCM with a reduced total iodine dose. Methods CTA of the abdomen on a 64-slice MDCT was performed on 15 anaesthetised pigs. Study pigs were divided into three groups of five each based on the iodine concentration and dose received: Group A (LCCM; 300 mg I ml–1), Group B (HCCM; 370 mg I ml–1) and Group C HCCM with 20% less iodine dose. The total iodine injected was kept constant (600 mg kg–1) in Groups A and B. Qualitative and quantitative analyses were performed to study and compare each group for image quality, visibility of the branch order of the superior mesenteric artery (SMA), artefacts, degree of enhancement in the aorta and main stem arteries and uniformity of enhancement in the aorta. Groups were compared using the analysis of variance test. Results The image quality of 64-slice MDCT angiography was excellent with a mean score of 4.63 and confident visualisation of the third to fifth order branches of the SMA in all groups. Group B demonstrated superior vascular enhancement, as compared with Groups A and C (p≤0.05). Uniform aortic enhancement was achieved with the use of LCCM and HCCM with 20% less iodine dose. Conclusion 64-slice MDCT angiography of the abdomen was of excellent quality. HCCM improves contrast enhancement and overall CTA image quality and allows the iodine dose to be reduced. PMID:21081582

  14. Comparison radiation dose of Z-axis automatic tube current modulation technique with fixed tube current multi-detector row CT scanning of lower extremity venography

    International Nuclear Information System (INIS)

    Yoo, Beong Gyu; Kweon, Dae Cheol; Lee, Jong Seok; Jang, Keun Jo; Jeon, Sang Hwan; Kim, Yong Soo

    2007-01-01

    Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of Multi-Detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, 70∼450 mA). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, Z-axis modulation resulted in reduction of CTDIvol (range, -6.5%∼-35.6%) and DLP (range,-0.2%∼-20.2%). Compared with manually selected fixed tube current, Z-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography

  15. Accuracy of 16-slice multi-detector CT to quantify the degree of coronary artery stenosis: Assessment of cross-sectional and longitudinal vessel reconstructions

    Energy Technology Data Exchange (ETDEWEB)

    Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States)]. E-mail: rcury@partners.org; Ferencik, Maros [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Achenbach, Stephan [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Department of Internal Medicine II, University of Erlangen (Germany); Pomerantsev, Eugene [Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Nieman, Koen [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Moselewski, Fabian [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Abbara, Suhny [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Jang, Ik-Kyung [Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Brady, Thomas J. [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Hoffmann, Udo [Department of Radiology, Massachusetts General Hospital, Boston, MA (United States)

    2006-03-15

    Background: Sixteen-slice multi-detector computed tomography (MDCT) permits reliable noninvasive detection of significant coronary stenosis based on qualitative visual assessment. The purpose of this study was to determine the accuracy of MDCT to quantify the degree of coronary stenosis as compared to quantitative coronary angiography (QCA) using two different reconstruction methods. Methods: We studied 69 coronary artery lesions from 38 consecutive patients that underwent 16-slice MDCT as a part of research study, which enrolled consecutive subjects scheduled for clinically indicated invasive coronary angiography. Nine coronary artery lesions with motion artifacts, heavily calcified plaques or stents were excluded from the analysis. The degree of stenosis was calculated by two independent readers non-blinded to the location of the stenosis, but blinded to the results of the QCA. MDCT luminal diameters were measured in cross-sectional multi-planar reformatted (CS-MPR) images created perpendicular to the centerline of the vessel and in 5 mm thin-slab maximum intensity projections (MIP) parallel to the long axis of the vessel. Both MDCT methods were compared against QCA. Results: The mean degree of stenosis as measured by MDCT was closely correlated to QCA for both methods (CS-MPR versus QCA: 61 {+-} 23% versus 64 {+-} 29%; r {sup 2} = 0.83, p < 0.001 and MIP versus QCA: 64 {+-} 22% versus 64 {+-} 29%; r {sup 2} = 0.84, p < 0.001 for MIP. Bland-Altman analysis demonstrated a negative bias of the degree of stenosis of -2.8 {+-} 12% using CS-MPR and a minimally positive bias of 0.6 {+-} 12% for MIP. In stratified analysis for lesion severity (mild, 0-40%; moderate, 41-70% or severe, >70%) the agreement between both CS-MPR and MIP was high when compared to QCA ({kappa} = 0.74 and 0.71, respectively). Conclusion: Multi-detector spiral CT permits accurate quantitative assessment of the degree of coronary stenosis in selected data sets of sufficient quality using both

  16. Anatomical analysis of incidental left atrial diverticula in patients with suspected coronary artery disease using 64-channel multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Shin, S.Y. [Department of Radiology, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Kwon, S.H., E-mail: Kwon98@khu.ac.kr [Department of Radiology, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Oh, J.H. [Department of Radiology, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    2011-10-15

    Aim: To describe and evaluate anatomical characterizations of incidental left atrial (LA) diverticula in patients with suspected coronary artery disease using 64-channel multidetector computed tomography (MDCT). Materials and methods: From October 2008 to June 2009, 2059 patients with suspected coronary artery disease underwent electrocardiogram-gated 64-channel MDCT. Five hundred and thirty-two LA diverticula were identified in 377 patients (18.3%, male to female ratio: 216:161, mean age 59 {+-} 10.89 years, range from 20 to 91 years). Two radiologists retrospectively analysed the number (single or multiple), size (diameter and length), shape (cystiform or tubiform), surface (smooth or irregular), and location (right or mid or left/upper or lower/lateral or posterior). If the length/diameter was <1.5, the diverticular shape was considered to be cystiform. Results: Among 532 LA diverticula, single (270/532, 51.1%), cystiform (411/532, 77.3%), and smooth (332/532, 62.4%) diverticula were found. The right upper region (255/532, 47.9%) was the most common location, followed by the left lateral area (172/532, 32.3%). The average diameter was 4.7 {+-} 2 mm (range from 1-19 mm), and the average length was 4.7 {+-} 2.1 mm (range 1-13 mm). The average ratio of length to diameter was 1.15 (range 0.25-1.45). The average number of diverticula was 2 {+-} 1.06 (range 1-5). Conclusion: Incidental LA diverticulum is not an uncommon finding in patients with suspected coronary artery disease. MDCT can provide anatomical details of LA diverticula. However, further studies are needed to determine their clinical significance.

  17. Advances in CT imaging for urolithiasis

    Directory of Open Access Journals (Sweden)

    Yasir Andrabi

    2015-01-01

    Full Text Available Urolithiasis is a common disease with increasing prevalence worldwide and a lifetime-estimated recurrence risk of over 50%. Imaging plays a critical role in the initial diagnosis, follow-up and urological management of urinary tract stone disease. Unenhanced helical computed tomography (CT is highly sensitive (>95% and specific (>96% in the diagnosis of urolithiasis and is the imaging investigation of choice for the initial assessment of patients with suspected urolithiasis. The emergence of multi-detector CT (MDCT and technological innovations in CT such as dual-energy CT (DECT has widened the scope of MDCT in the stone disease management from initial diagnosis to encompass treatment planning and monitoring of treatment success. DECT has been shown to enhance pre-treatment characterization of stone composition in comparison with conventional MDCT and is being increasingly used. Although CT-related radiation dose exposure remains a valid concern, the use of low-dose MDCT protocols and integration of newer iterative reconstruction algorithms into routine CT practice has resulted in a substantial decrease in ionizing radiation exposure. In this review article, our intent is to discuss the role of MDCT in the diagnosis and post-treatment evaluation of urolithiasis and review the impact of emerging CT technologies such as dual energy in clinical practice.

  18. Multi-detector row CT of the kidney: Optimizing scan delays for bolus tracking techniques of arterial, corticomedullary, and nephrographic phases

    Energy Technology Data Exchange (ETDEWEB)

    Goshima, Satoshi [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Kanematsu, Masayuki [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Department of Radiology Services, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Nishibori, Hironori; Kondo, Hiroshi; Tsuge, Yusuke [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Yokoyama, Ryujiro; Miyoshi, Toshiharu [Department of Radiology Services, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Onozuka, Minoru [Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka, Kanagawa (Japan); Shiratori, Yoshimune [Department of Medical Informatics, Gifu University School of Medicine, Gifu (Japan); Moriyama, Noriyuki [Department of Diagnostic Radiology, National Cancer Center Hospital, Tsukiji, Chuo-Ku, Tokyo (Japan); Bae, Kyongtae T. [Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO (United States)

    2007-09-15

    Purpose: To determine optimal scan delays for renal arterial-, corticomedullary-, and nephrographic-phase imaging with multi-detector row computed tomography (MDCT) of the kidney using a bolus-tracking technique. Methods and materials: One hundred and twenty-eight patients underwent three-phase CT scan of the kidney with eight-row MDCT after receiving 2 mL/kg of 300 mg I/mL contrast medium at 4 mL/s. Patients were prospectively randomized into three groups with different scan delays for the three scan phases (arterial, corticomedullary, and nephrographic) after bolus-tracking triggered at 50 HU of aortic contrast enhancement: group 1 (5, 20, 45 s); group 2 (10, 25, 50 s); and group 3 (15, 30, 55 s). Mean CT values (HU) of the abdominal aorta, renal artery, renal vein, renal cortex, and renal medulla were measured; increases in CT values pre- to post-contrast were assessed as contrast enhancement. Renal artery-to-vein and renal cortex-to-medulla contrast differences were also assessed. Qualitative analysis was also performed. Results: Mean renal artery enhancement was 240-288 HU at 5-15 s after the trigger and peaked at 10 s (P < .001). Mean renal cortical enhancement was 195-217 HU at 10-30 s and peaked at 25 s (P < .01). Contrast enhancement in the renal medulla increased gradually and reached mean 145 HU at 55 s. Cortex-to-medulla contrast difference was high (110-140 HU) at 5-30 s and decreased below 30 HU at 45 s after the trigger. Renal artery-to-vein contrast difference was high (121-125 HU) at 5-10 s. Qualitative results correlated well with quantitative results. Conclusion: For the injection protocol used in this study, optimal scan delays after the bolus-tracking trigger were 5-10 s for renal arterial, 15-25 s for corticomedullary, and 50-55 s for nephrographic phases.

  19. Evaluation of image quality and radiation dose at prospective ECG-triggered axial 256-slice multi-detector CT in infants with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Mei-ping; Liang, Chang-hong; Zhao, Zhen-jun; Liu, Hui; Li, Jing-lei; Zhang, Jin-e; Cui, Yan-hai; Yang, Lin; Liu, Qi-shun [Guangdong Academy of Medical Sciences, Guangdong General Hospital, Department of Radiology, Guangzhou (China); Ivanc, Thomas B.; Vembar, Mani [Philips Healthcare, CT Clinical Science, Highland Heights, OH (United States)

    2011-07-15

    There are a limited number of reports on the technical and clinical feasibility of prospective electrocardiogram (ECG)-gated multi-detector computed tomography (MDCT) in infants with congenital heart disease (CHD). To evaluate image quality and radiation dose at weight-based low-dose prospectively gated 256-slice MDCT angiography in infants with CHD. From November 2009 to February 2010, 64 consecutive infants with CHD referred for pre-operative or post-operative CT were included. All were scanned on a 256-slice MDCT system utilizing a low-dose protocol (80 kVp and 60-120 mAs depending on weight: 60 mAs for {<=}3 kg, 80 mAs for 3.1-6 kg, 100 mAs for 6.1-10 kg, 120 mAs for 10.1-15 kg). No serious adverse events were recorded. A total of 174 cardiac deformities, confirmed by surgery or heart catheterization, were studied. The sensitivity of MDCT for cardiac deformities was 97.1%; specificity, 99.4%; accuracy, 95.9%. The mean heart rate during scan was 136.7 {+-} 14.9/min (range, 91-160) with a corresponding heart rate variability of 2.8 {+-} 2.2/min (range, 0-8). Mean scan length was 115.3 {+-} 11.7 mm (range, 93.6-143.3). Mean volume CT dose index, mean dose-length product and effective dose were 2.1 {+-} 0.4 mGy (range, 1.5-2.8), 24.7 {+-} 5.9 mGy.cm (range, 14.7-35.8) and 1.6 {+-} 0.3 mSv (range, 1.1-2.5), respectively. Diagnostic-quality images were achieved in all cases. Satisfactory diagnostic quality for visualization of all/proximal/distal coronary artery segments was achieved in 88.4/98.8/80.0% of the scans. Low-dose prospectively gated axial 256-slice CT angiography is a valuable tool in the routine clinical evaluation of infants with CHD, providing a comprehensive three-dimensional evaluation of the cardiac anatomy, including the coronary arteries. (orig.)

  20. Multidetector CT of Locally Invasive Advanced Gastric Cancer: Value of Oblique Coronal Reconstructed Images for the Assessment of Local Invasion

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jin Hee; Kim, Ah Yong; Kim, Hye Jin; Yook, Jeong Hwan; Yu, Eun Sil; Jang, Yoon Jin; Park, Seong Ho; Shin, Yong Moon; Ha, Hyun Kwon [Asan Medical Center, Seoul (Korea, Republic of)

    2010-01-15

    To evaluate the diagnostic value of oblique coronal reconstructed CT images to determine the local invasion of advanced gastric cancer (AGC). Thirty-four consecutive patients, who were suspected to have locally invasive advanced gastric cancer (more than T3 stage) on a preoperative MDCT scan and underwent a diagnostic or curative laparotomy, were enrolled in this study. Two reviewers performed an independent blind review of three series of MDCT images in random order; axial (AXI), conventional coronal (CCI), and oblique coronal (OCI) (parallel to long axis of gastric body and pancreas) images. In assessing the local invasion, the reader's confidence for the local invasion of AGC was graded using a five point scale (1 = definitely negative, 5 = definitely positive: T4). With surgical findings and histopathological proofs as reference standards, the diagnostic performance of the three different plans of CT images was employed for the verification of local invasion of AGC on a preoperative CT scan using the receiver operating characteristic (ROC) method. Agreements between the two reviewers were analyzed using weighted kappa statistics. Results: In 19 out of 34 patients, local invasion was confirmed surgically or histopathologically (13 pancreas invasion, 6 liver invasion, 4 major vascular invasion, 3 colon and mesocolon invasion, and 2 spleen invasion). The diagnostic performance of OCI was superior to AXI or CCI in the local invasion of AGC. The differences in the area under the curve of AXI (0.770 {+-} 0.087, 0.700 {+-} 0.094), CCI (0.884 {+-} 0.058, 0.958 {+-} 0.038), and OCI (0.954 {+-} 0.050, 0.956 {+-} 0.049), were statistically significant for both reviewers. Inter-observer agreement was excellent for OCI ({kappa}= .973), which was greater than CCI (({kappa}= .839), and AXI (({kappa}= .763). On a CT scan, OCI might be a useful imaging technique in evaluating locally invasive advanced gastric cancer.

  1. The vascularized groin lymph node flap (VGLN): Anatomical study and flap planning using multi-detector CT scanner. The golden triangle for flap harvesting.

    Science.gov (United States)

    Zeltzer, Assaf A; Anzarut, Alexander; Braeckmans, Delphine; Seidenstuecker, Katrin; Hendrickx, Benoit; Van Hedent, Eddy; Hamdi, Moustapha

    2017-09-01

    A growing number of surgeons perform lymph node transfers for the treatment of lymphedema. When harvesting a vascularized lymph node groin flap (VGLNF) one of the major concerns is the potential risk of iatrogenic lymphedema of the donor-site. This article helps understanding of the lymph node distribution of the groin in order to minimize this risk. Fifty consecutive patients undergoing abdominal mapping by multi-detector CT scanner were included and 100 groins analyzed. The groin was divided in three zones (of which zone II is the safe zone) and lymph nodes were counted and mapped with their distances to anatomic landmarks. Further node units were plotted and counted. The average age was 48 years. A mean number of nodes of 6.5/groin was found. In zone II, which is our zone of interest a mean of 3.1 nodes were counted with a mean size of 7.8 mm. In three patients no nodes were found in zone II. In five patients nodes were seen in zone II but were not sufficient in size or number to be considered a lymph node unit. On average the lymph node unit in zone II was found to be 48.3 mm from the pubic tubercle when projected on a line from the pubic tubercle to the anterior superior iliac spine, 16.0 mm caudal to this line, and 20.4 mm above the groin crease. On average the lymph node unit was a mean of 41.7 mm lateral to the SCIV-SIEV confluence. This study provides increased understanding of the lymphatic anatomy in zone II of the groin flap and suggests a refined technique for designing the VGLNF. As with any flap there is a degree of individual patient variability. However, having information on the most common anatomy and flap design is of great value. © 2017 Wiley Periodicals, Inc.

  2. Volume-rendered hemorrhage-responsible arteriogram created by 64 multidetector-row CT during aortography: utility for catheterization in transcatheter arterial embolization for acute arterial bleeding.

    Science.gov (United States)

    Minamiguchi, Hiroki; Kawai, Nobuyuki; Sato, Morio; Ikoma, Akira; Sanda, Hiroki; Nakata, Kouhei; Tanaka, Fumihiro; Nakai, Motoki; Sonomura, Tetsuo; Murotani, Kazuhiro; Hosokawa, Seiki; Nishioku, Tadayoshi

    2014-01-01

    Aortography for detecting hemorrhage is limited when determining the catheter treatment strategy because the artery responsible for hemorrhage commonly overlaps organs and non-responsible arteries. Selective catheterization of untargeted arteries would result in repeated arteriography, large volumes of contrast medium, and extended time. A volume-rendered hemorrhage-responsible arteriogram created with 64 multidetector-row CT (64MDCT) during aortography (MDCTAo) can be used both for hemorrhage mapping and catheter navigation. The MDCTAo depicted hemorrhage in 61 of 71 cases of suspected acute arterial bleeding treated at our institute in the last 3 years. Complete hemostasis by embolization was achieved in all cases. The hemorrhage-responsible arteriogram was used for navigation during catheterization, thus assisting successful embolization. Hemorrhage was not visualized in the remaining 10 patients, of whom 6 had a pseudoaneurysm in a visceral artery; 1 with urinary bladder bleeding and 1 with chest wall hemorrhage had gaze tamponade; and 1 with urinary bladder hemorrhage and 1 with uterine hemorrhage had spastic arteries. Six patients with pseudoaneurysm underwent preventive embolization and the other 4 patients were managed by watchful observation. MDCTAo has the advantage of depicting the arteries responsible for hemoptysis, whether from the bronchial arteries or other systemic arteries, in a single scan. MDCTAo is particularly useful for identifying the source of acute arterial bleeding in the pancreatic arcade area, which is supplied by both the celiac and superior mesenteric arteries. In a case of pelvic hemorrhage, MDCTAo identified the responsible artery from among numerous overlapping visceral arteries that branched from the internal iliac arteries. In conclusion, a hemorrhage-responsible arteriogram created by 64MDCT immediately before catheterization is useful for deciding the catheter treatment strategy for acute arterial bleeding.

  3. Acute pulmonary embolism: prediction of cor pulmonale and short-term patient survival from assessment of cardiac dimensions in routine multidetector-row CT

    International Nuclear Information System (INIS)

    Engeike, C.; Rummeny, E.; Marten, K.

    2006-01-01

    Purpose: evaluation of the prognostic value of morphological cardiac parameters in patients with suspected and incidental acute pulmonary embolism (PE) using multidetector-row chest CT (MSCT). Materials and methods: 2335 consecutive MSCT scans were evaluated for the presence of PE. The arterial enhancement and analysability of pulmonary arteries and the heart were assessed as parameters of the scan quality. The diastolic right and left ventricular short axes (RV D , LV D ) and the interventricular septal deviation (ISD) were measured in all PE-positive patients and the echocardiography reports were reviewed. The clinical data assessment included cardio-respiratory and other co-morbidities, systemic anticoagulant therapy (ACT), and the 30-day outcome. Predictors of acute cor pulmonale and the short-term outcome were calculated by univariate and multivariate logistic regressions including odds ratios (OR) and ROC analyses using positive (PPV) and negative predictive values (NPV). Results: 90 patients with acute PE were included (36 with clinically suspected PE, 54 with incidental PE). 26 patients had cardio-respiratory co-morbidities. Four patients underwent systemic thrombolysis, 43 underwent anticoagulation in therapeutic doses, 19 underwent anticoagulation in prophylactic doses, and 24 patients did not undergo ACT. 15 of 41 patients had echocardiographic evidence of acute cor pulmonale. 8 patients died within 30 days. The RV D was the best independent predictor of acute cor pulmonale (p = 0,002, OR = 9.16, PPV = 0.68, NPV=1 at 4.49 cm cut off) and short-term outcome (p= 0,0005, OR = 2.82, PPV = 0.23, NPV = 0.98 at 4.75 cm cut off). The RV D /LV D ratio had a PPV of 0.85 for cor pulmonale. (orig.)

  4. Quantification of myocardial blood flow using dynamic 320-row multi-detector CT as compared with ¹⁵O-H₂O PET.

    Science.gov (United States)

    Kikuchi, Yasuka; Oyama-Manabe, Noriko; Naya, Masanao; Manabe, Osamu; Tomiyama, Yuuki; Sasaki, Tsukasa; Katoh, Chietsugu; Kudo, Kohsuke; Tamaki, Nagara; Shirato, Hiroki

    2014-07-01

    This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against (15)O-H₂O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). Correlation between MBF of MDCT and PET was strong (r = 0.95, P dynamic CTP and PET (r = 0.67, P = 0.0126). CFRCT in the CAD group (2.3 ± 0.8) was significantly lower than that in the validation group (5.2 ± 1.8) (P = 0.0011). We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. • MBF and CFR can be calculated using dynamic CTP with 320-row MDCT. • MBF and CFR showed good correlation between dynamic CTP and PET. • Lower CFR was well demonstrated in CAD patients by dynamic CTP.

  5. Multi-detector row CT of the head and neck: comparison of different volumes of contrast material with and without a saline chaser

    International Nuclear Information System (INIS)

    Yoon, Dae Young; You, Su Yeon; Choi, Chul Soon; Chang, Suk Ki; Yun, Eun Joo; Seo, Young Lan; Park, Sang Joon; Lee, Yu-Jin; Moon, Jeung Hee; Rho, Young-Soo; Kim, Jin-Hwan

    2006-01-01

    The aim of this study was to determine the effect of different volumes of contrast material with and without a saline chaser on tissue enhancement in multidetector row CT (MDCT) of the head and neck. In a blind prospective fashion, 120 patients were randomized into the following four groups: group 1, 80 ml contrast material administered at a flow rate of 2.0 ml/s; group 2, 80 ml followed by 40 ml saline at 2.0 ml/s; group 3, 60 ml at 1.5 ml/s; and group 4, 60 ml followed by 30 ml saline at 1.5 ml/s. The attenuation values of the carotid artery, internal jugular vein, and muscle were measured at an interval of 1.5 s in each patient. The degree of perivenous artifacts was subjectively assessed. Mean attenuation values in the carotid artery and internal jugular vein were significantly higher in groups 1 and 2 than in groups 3 and 4. The width of the diagnostic window (both carotid and jugular enhancement >150 HU) were significantly longer in groups 1 and 2 than in groups 3 and 4. The addition of a saline chaser did not result in improved vascular enhancement or a wider diagnostic window, but reduced perivenous artifacts, compared with using contrast material alone. Reduction of contrast material from 80 to 60 ml results in insufficient enhancement of neck vessels. In addition, the benefit of a saline chaser technique is not obvious except for its ability to reduce perivenous artifacts. (orig.)

  6. Radiological profile of anemia on unenhanced MDCT of the thorax

    International Nuclear Information System (INIS)

    Kamel, Ehab M.; Rizzo, Elena; Duran, Rafael; Goncalves-Matoso, Vasco; Schnyder, Pierre; Duchosal, Michel A.; Qanadli, Salah D.

    2008-01-01

    Our aim was to investigate the diagnostic value of unenhanced MDCT in anemic patients. Fifty consecutive patients with proven anemia and 50 nonanemic matched group for age, sex and body mass index were evaluated. In either group, hemoglobin levels were assessed no more than 24 h from an unenhanced CT of the thorax. For each patient, the presence of a hyperattenuating aortic wall (aortic ring sign) and/or dense interventricular septum (subjective parameters) were identified by two radiologists who were blinded to the laboratory findings. Furthermore, the aortic CT attenuation values (objective parameter) were also obtained and correlated with the hemoglobin levels. The sensitivity and specificity in detecting anemia were calculated for each variable, and ROC analysis was generated for subjective and objective parameters. Subjective image analysis revealed that the aortic ring sign was more sensitive than the interventricular septum sign for anemia detection (84% vs. 72%), whereas this latter sign was more specific (100% vs. 92%). A good correlation (r=0.60) was observed between the aortic CT attenuation values and the hemoglobin levels in the whole study population. Using a threshold of ≤35 HU for anemia diagnosis, the sensitivity and specificity of aortic CT attenuation value were 84% and 94%, respectively, with the largest area under the curve (0.89) among all diagnostic criteria. However, the best trade-off between sensitivity (80%) and specificity (100%) was obtained from combining both subjective and objective analysis. Interpreting anemia upon unnenhanced MDCT of the thorax is quite feasible. A diagnostic approach that considers both subjective and objective analysis offers the best trade-off between sensitivity and specificity. (orig.)

  7. Impaired left ventricular function has a detrimental effect on image quality in multi-detector row CT coronary angiography

    International Nuclear Information System (INIS)

    Manghat, N.E.; Morgan-Hughes, G.J.; Shaw, S.R.; Marshall, A.J.; Roobottom, C.A.

    2008-01-01

    Aim: To determine whether there is a relationship between left ventricular (LV) haemodynamic parameters, circulation times, and arterial contrast opacification that might affect the image quality of computed tomography (CT) coronary angiography. Methods: Thirty-six patients were included in the study: 18 with cardiomyopathy (CM) and LV dilatation of suspected ischaemic aetiology [age 57.9 ± 13.7 years, range 30-77 years; 14 male, four female; body mass index (BMI) = 27.7 ± 4.5, range 25.5-31.8] and 18 controls (age 62.3 ± 9.4 years, range 47-89 years; 10 male, eight female; BMI 27.8 ± 6.6; range 19.2-33.6). Coronary artery image quality was assessed using a three-point visual scale; contrast medium circulation times, aortic root contrast attenuation, and LV functional parameters were studied. Results: Visually reduced contrast opacification impaired image quality more often in the CM group than the control group (27.4 versus 5.1%). A total of 55.6% CM patients had a contrast transit time ranging from 30-75 s; the number of 'unassessable' segments increased with increasing transit time conforming to a fitted quadratic model (R 2 = 0.74). The relationship between LV ejection fraction and contrast attenuation may also conform to a quadratic model (R 2 = 0.71). Conclusion: LV haemodynamics influence coronary artery opacification using cardiac CT, and users imaging this subgroup must do so with the knowledge of this potential pitfall. The results indicate the need for further studies examining CT protocols in this clinical subgroup

  8. Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults

    International Nuclear Information System (INIS)

    Desai, Gaurav S.; Uppot, Raul N.; Kambadakone, Avinash R.; Yu, Elaine W.; Sahani, Dushyant V.

    2012-01-01

    To compare image quality and radiation dose using Adaptive Statistical Iterative Reconstruction (ASiR) and Filtered Back Projection (FBP) in patients weighing ≥91 kg. In this Institution Review Board-approved retrospective study, single-phase contrast-enhanced abdominopelvic CT examinations of 100 adults weighing ≥91 kg (mean body weight: 107.6 ± 17.4 kg range: 91-181.9 kg) with (1) ASiR and (2) FBP were reviewed by two readers in a blinded fashion for subjective measures of image quality (using a subjective standardized numerical scale and objective noise) and for radiation exposure. Imaging parameters and radiation dose results of the two techniques were compared within weight and BMI sub-categories. All examinations were found to be of adequate quality. Both subjective (mean = 1.4 ± 0.5 vs. 1.6 ± 0.6, P < 0.05) and objective noise (13.0 ± 3.2 vs.19.5 ± 5.7, P < 0.0001) were lower with ASiR. Average radiation dose reduction of 31.5 % was achieved using ASiR (mean CTDIvol. ASiR: 13.5 ± 7.3 mGy; FBP: 19.7 ± 9.0 mGy, P < 0.0001). Other measures of image quality were comparable between the two techniques. Trends for all parameters were similar in patients across weight and BMI sub-categories. In obese individuals, abdominal CT images reconstructed using ASiR provide diagnostic images with reduced image noise at lower radiation dose. circle CT images in obese adults are noisy, even with high radiation dose. (orig.)

  9. Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults

    Energy Technology Data Exchange (ETDEWEB)

    Desai, Gaurav S.; Uppot, Raul N.; Kambadakone, Avinash R. [Harvard Medical School, Department of Abdominal Imaging and Intervention, Massachusetts General Hospital, Boston, MA (United States); Yu, Elaine W. [Harvard Medical School, Massachusetts General Hospital, Boston, MA (United States); Sahani, Dushyant V. [Harvard Medical School, Department of Abdominal Imaging and Intervention, Massachusetts General Hospital, Boston, MA (United States); Harvard Medical School, Department of Radiology, Division of Abdominal Imaging and Intervention, Massachusetts General Hospital, Boston, MA (United States)

    2012-08-15

    To compare image quality and radiation dose using Adaptive Statistical Iterative Reconstruction (ASiR) and Filtered Back Projection (FBP) in patients weighing {>=}91 kg. In this Institution Review Board-approved retrospective study, single-phase contrast-enhanced abdominopelvic CT examinations of 100 adults weighing {>=}91 kg (mean body weight: 107.6 {+-} 17.4 kg range: 91-181.9 kg) with (1) ASiR and (2) FBP were reviewed by two readers in a blinded fashion for subjective measures of image quality (using a subjective standardized numerical scale and objective noise) and for radiation exposure. Imaging parameters and radiation dose results of the two techniques were compared within weight and BMI sub-categories. All examinations were found to be of adequate quality. Both subjective (mean = 1.4 {+-} 0.5 vs. 1.6 {+-} 0.6, P < 0.05) and objective noise (13.0 {+-} 3.2 vs.19.5 {+-} 5.7, P < 0.0001) were lower with ASiR. Average radiation dose reduction of 31.5 % was achieved using ASiR (mean CTDIvol. ASiR: 13.5 {+-} 7.3 mGy; FBP: 19.7 {+-} 9.0 mGy, P < 0.0001). Other measures of image quality were comparable between the two techniques. Trends for all parameters were similar in patients across weight and BMI sub-categories. In obese individuals, abdominal CT images reconstructed using ASiR provide diagnostic images with reduced image noise at lower radiation dose. circle CT images in obese adults are noisy, even with high radiation dose. (orig.)

  10. Dual source multidetector CT-angiography before transcatheter aortic valve implantation (TAVI) using a high-pitch spiral acquisition mode

    Energy Technology Data Exchange (ETDEWEB)

    Wuest, W.; Anders, K.; May, M.S.; Uder, M. [University of Erlangen, Department of Radiology, Erlangen (Germany); Schuhbaeck, A.; Gauss, S.; Marwan, M.; Arnold, M.; Muschiol, G.; Daniel, W.G.; Achenbach, S. [University of Erlangen, Department of Cardiology, Erlangen (Germany); Ensminger, S. [University of Erlangen, Department of Cardiac Surgery, Erlangen (Germany)

    2012-01-15

    Transcatheter Aortic Valve Implantation (TAVI) is an alternative to surgical valve replacement in high risk patients. Angiography of the aortic root, aorta and iliac arteries is required to select suitable candidates, but contrast agents can be harmful due to impaired renal function. We evaluated ECG-triggered high-pitch spiral dual source Computed Tomography (CT) with minimized volume of contrast agent to assess aortic root anatomy and vascular access. 42 patients (82 {+-} 6 years) scheduled for TAVI underwent dual source (DS) CT angiography (CTA) of the aorta using a prospectively ECG-triggered high-pitch spiral mode (pitch = 3.4) with 40 mL iodinated contrast agent. We analyzed aortic root/iliac dimensions, attenuation, contrast to noise ratio (CNR), image noise and radiation exposure. Aortic root/iliac dimensions and distance of coronary ostia from the annulus could be determined in all cases. Mean aortic and iliac artery attenuation was 320 {+-} 70 HU and 340 {+-} 77 HU. Aortic/iliac CNR was 21.7 {+-} 6.8 HU and 14.5 {+-} 5.4 HU using 100 kV (18.8 {+-} 4.1 HU and 8.7 {+-} 2.6 HU using 120 kV). Mean effective dose was 4.5 {+-} 1.2 mSv. High-pitch spiral DSCTA can be used to assess the entire aorta and iliac arteries in TAVI candidates with a low volume of contrast agent while preserving diagnostic image quality. (orig.)

  11. Coronary artery anomalies: Assessment with electrocardiography-gate multidetector-row CT at a single center in Korea

    International Nuclear Information System (INIS)

    Yi, Bo Ram; Sun, Joo Sung; Yang, Hyoung Mo; Kang, Doo Kyoung

    2015-01-01

    To determine the prevalence of coronary anomalies using coronary computed tomography angiography (CCTA) and to evaluate the relationship between coronary artery anomalies and chest pain. A total of 12676 patients underwent CCTA scans at our institution between December 2006 and April 2013 using a 64-slice CT and a 128-slice dual-source CT. We determined the prevalence of coronary artery anomalies according to the classification system proposed by Greenberg. The presence or absence of chest pain with each coronary artery anomaly was also evaluated. Coronary anomalies were found in 176 patients (1.39%) at our institute. Anomalies of origination, course, and termination were detected in 118 (0.93%), 28 (0.22%), and 30 (0.24%) patients, respectively. After the exclusion of 32 patients with combined heart disease, typical (n = 16; 11.1%) or atypical (n = 28; 19.4%) chest pain was present in 44 (30.6%) of the 144 patients at the time of diagnosis. The prevalence of coronary artery anomalies was 1.39% at our hospital. After the exclusion of patients with combined heart disease, 11.1% had typical chest pain at the time of diagnosis.

  12. Three-dimensional fracture visualisation of multidetector CT of the skull base in trauma patients: comparison of three reconstruction algorithms

    International Nuclear Information System (INIS)

    Ringl, Helmut; Schernthaner, Ruediger; Philipp, Marcel O.; Metz-Schimmerl, Sylvia; Czerny, Christian; Weber, Michael; Steiner-Ringl, Andrea; Peloschek, Philipp; Herold, Christian J.; Schima, Wolfgang; Gaebler, Christian

    2009-01-01

    The purpose of this study was to retrospectively assess the detection rate of skull-base fractures for three different three-dimensional (3D) reconstruction methods of cranial CT examinations in trauma patients. A total of 130 cranial CT examinations of patients with previous head trauma were subjected to 3D reconstruction of the skull base, using solid (SVR) and transparent (TVR) volume-rendering technique and maximum intensity projection (MIP). Three radiologists independently evaluated all reconstructions as well as standard high-resolution multiplanar reformations (HR-MPRs). Mean fracture detection rates for all readers reading rotating reconstructions were 39, 36, 61 and 64% for SVR, TVR, MIP and HR-MPR respectively. Although not significantly different from HR-MPR with respect to sensitivity (P = 0.9), MIP visualised 18% of fractures that were not reported in HR-MPR. Because of the relatively low detection rate using HR-MPRs alone, we recommend reading MIP reconstructions in addition to the obligatory HR-MPRs to improve fracture detection. (orig.)

  13. Unenhanced Computed Tomography to Visualize Hollow Viscera and/or Mesenteric Injury After Blunt Abdominal Trauma: A Single-Institution Experience.

    Science.gov (United States)

    Yang, Xu-Yang; Wei, Ming-Tian; Jin, Cheng-Wu; Wang, Meng; Wang, Zi-Qiang

    2016-03-01

    To identify and describe the major features of unenhanced computed tomography (CT) images of blunt hollow viscera and/or mesenteric injury (BHVI/MI) and to determine the value of unenhanced CT in the diagnosis of BHVI/MI. This retrospective study included 151 patients who underwent unenhanced CT before laparotomy for blunt abdominal trauma between January 2011 and December 2013. According to surgical observations, patients were classified as having BHVI/MI (n = 73) or not (n = 78). Sensitivity, specificity, P values, and likelihood ratios were calculated by comparing CT findings between the 2 groups. Six significant CT findings (P tool for BHVI/MI after blunt abdominal trauma. Six key features on CT were correlated with BHVI/MI.

  14. Exposure (mAs) optimisation of a multi-detector CT protocol for hepatic lesion detection: are thinner slices better?

    International Nuclear Information System (INIS)

    Dobeli, Karen L.; Lewis, Sarah J.; Meikle, Steven R.; Brennan, Patrick C.; Thiele, David L.

    2014-01-01

    The purpose of this work was to determine the exposure-optimised slice thickness for hepatic lesion detection with CT. A phantom containing spheres (diameter 9.5, 4.8 and 2.4mm) with CT density 10 HU below the background (50 HU) was scanned at 125, 100, 75 and 50 mAs. Data were reconstructed at 5-, 3- and 1-mm slice thicknesses. Noise, contrast-to-noise ratio (CNR), area under the curve (AUC) as calculated using receiver operating characteristic analysis and sensitivity representing lesion detection were calculated and compared. Compared with the 125 mAs/5mm slice thickness setting, significant reductions in AUC were found for 75 mAs (P<0.01) and 50 mAs (P<0.05) at 1- and 3-mm thicknesses, respectively; sensitivity for the 9.5-mm sphere was significantly reduced for 75 (P<0.05) and 50 mAs (P<0.01) at 1-mm thickness; sensitivity for the 4.8-mm sphere was significantly lower for 100, 75 and 50 mAs at all three slice thicknesses (P<0.05). The 2.4-mm sphere was rarely detected. At each slice thickness, noise at 100, 75 and 50 mAs exposures was approximately 10, 30 and 50% higher, respectively, than that at 125 mAs exposure. CNRs decreased in an irregular manner with reductions in exposure and slice thickness. This study demonstrated no advantage to using slices below 5mm thickness, and consequently thinner slices are not necessarily better.

  15. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ...

  16. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  19. Comparison of diagnostic value of multidetector computed tomography and X-ray in the detection of body packing

    Energy Technology Data Exchange (ETDEWEB)

    Bulakci, Mesut, E-mail: mesutbulakci@yahoo.com [Department of Radiology, Haseki Training and Research Hospital, 34096 Aksaray, Istanbul (Turkey); Kalelioglu, Tuba, E-mail: tubakarsakarya@hotmail.com [Department of Radiology, Haseki Training and Research Hospital, 34096 Aksaray, Istanbul (Turkey); Bulakci, Betul Bozkurt, E-mail: dr.betulbozkurt@gmail.com [Department of Family Medicine, Istanbul University, Istanbul Faculty of Medicine, 34390 Capa, Istanbul (Turkey); Kiris, Adem, E-mail: ademkiris@hotmail.com [Department of Radiology, Haseki Training and Research Hospital, 34096 Aksaray, Istanbul (Turkey)

    2013-08-15

    Objective: Radiologists and other clinicians are facing an increasing number of illegal drug-related medical conditions. We aimed to draw attention to this growing global problem and to highlight some of the important points related to diagnosis and follow-up of body packing. We compare the diagnostic performance of unenhanced multidetector CT (MDCT) and abdomen X-ray for the detection of drug-filled packets. Materials and methods: Sixty-seven suspects, who underwent both CT and X-ray examinations, have been included in the study. All MDCT and X-ray images were independently and retrospectively reviewed by two observers with different degrees of experience in abdomen imaging. Fifty-two of them were identified as body packers finally. Interobserver agreement, sensitivity, specificity, positive and negative predictive value were calculated. Results: Two types of packets with different characteristics were identified in all body packers. Type 1 packets (solid-state drug) were found in 41 patients and type 2 packets (liquid cocaine) in 11 patients. All statistical analyses concern the detection of any packets. That is, the whole evaluation has been performed per patient. Sensitivity/specificity values of type 1 and type 2 packets for MDCT were 100–98%/100–100% and 100–100%/100–100%, respectively. Besides, sensitivity/specificity values of type 1 and type 2 packets for X-ray were 93–90%/100–91% and 64–45%/73–71%, respectively. In addition, interobserver agreements for detection of any packets were excellent (κ = 0.96) and good (κ = 0.75) for interpretation of MDCT and X-ray, respectively. Conclusion: Unenhanced MDCT is a fast, accurate and easily used diagnostic tool with high sensitivity and specificity for the exact diagnosis of body packing.

  20. The emerging role of multidetector row CT angiography in the diagnosis of cervical arterial dissection: preliminary study

    International Nuclear Information System (INIS)

    Elijovich, Lucas; Kazmi, Khuram; Gauvrit, Jean Y.; Law, Meng

    2006-01-01

    Cervical artery dissection is an important cause of ischemic stroke, particularly in young patients. The diagnosis can be made with invasive catheter angiography or non-invasive imaging, either with MRI in conjunction with MR angiography (MRA) or CT angiography (CTA). Both modalities have been shown to have a high specificity and sensitivity. New developments such as multi-slice CTA (MSCTA) are emerging as an alternative methods for imaging the cervical and intracranial arteries. However, the contribution of modern MSCTA to carotid artery dissection has not been reported. We present a retrospective series of seven patients in whom both MSCTA and cervical axial T1 MRI and MRA were performed in the acute to subacute setting of internal carotid artery dissection. Carotid artery dissection was identified in all seven patients by MSCTA. The combination of MRI and MRA identified dissection in five of the seven patients. Additionally, a pseudoaneurysm was identified by MSCTA that was missed by MRI and MRA. Our findings confirm that MSCTA is a complementary technique in comparison to cervical axial T1 MRI and cervical MRA for diagnosing carotid artery dissection, and at times may provide additional information that can impact patient management. (orig.)

  1. Acute subarachnoid hemorrhage: using 64-slice multidetector CT angiography to ''triage'' patients' treatment

    Energy Technology Data Exchange (ETDEWEB)

    Agid, R.; Lee, S.K.; Willinsky, R.A.; Farb, R.I.; TerBrugge, K.G. [Toronto Western Hospital, Division of Neuroradiology, Department of Medical Imaging, Toronto, Ontario (Canada)

    2006-11-15

    To evaluate the clinical role of CT angiography (CTA) in patients with acute subarachnoid hemorrhage (SAH) for treatment decision-making. Consecutive patients with acute SAH had CTA using a 64-slice scanner for initial clinical decision-making. Image processing included multiplanar volume reformatted (MPVR) maximum intensity projections (MIP) and 3D volume-rendered reconstructions. CTAs were used for (1) evaluating the cause of SAH, and (2) triaging aneurysm-bearing patients to the more appropriate management, either surgical clipping or endovascular coiling. CTA findings were confirmed by neurosurgical exploration or catheter angiography (digital subtraction angiography, DSA). Successful coiling provided evidence that triaging to endovascular treatment was correct. Included in the study were 73 patients. CTA findings were confirmed by DSA or neurosurgical operation in 65 patients, and of these 65, 47 had aneurysmal SAH, 3 had vasculitis, 1 had arterial dissection and 14 had no underlying arterial abnormality. The cause of SAH was detected with CTA in 62 out of the 65 patients (95.4%, sensitivity 94%, specificity 100%). CTA revealed the aneurysm in 46 of 47 patients (98%, sensitivity 98%, specificity 100%, positive predictive value 100%, negative predictive value 82.3%), 1 of 3 vasculitides and 1 of 1 dissection. Of the 46 patients with aneurysm, 44 (95.7%) were referred for treatment based on CTA. In 2 patients (2 of 46, 4.4%) CTA was not informative enough to choose treatment requiring DSA. Of the 44 patients, 27 (61.4%) were referred to endovascular treatment and successful coiling was achieved in 25 (25 of 27, 92.6%). CTA using a 64-slice scanner is an accurate tool for detecting and characterizing aneurysms in acute SAH. CTA is useful in the decision process whether to coil or clip an aneurysm. (orig.)

  2. Depiction of variants of the portal confluence venous system using multidetector row CT. Analysis of 916 cases

    Energy Technology Data Exchange (ETDEWEB)

    Krumm, P.; Schraml, C.; Bretschneider, C.; Seeger, A.; Klumpp, B.; Kramer, U.; Claussen, C.D.; Miller, S. [Universitaetsklinikum Tuebingen (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie

    2011-12-15

    Purpose: Detailed knowledge of the venous mesenteric system is important for gastrointestinal surgery, particularly for transplantation planning and surgery and for the comprehension of perioperative complications that may influence patient outcome. Data about the mesenteric venous anatomy in the literature varies substantially. The purpose of this study was to categorize venous mesenteric variants and to determine their incidence. Materials and Methods: We included 916 patients requiring diagnostic abdominal CT in the portal venous phase. The mesenteric vein anatomy was categorized as follows: 1. the inferior mesenteric vein (IMV) enters the splenic vein (SV); 2. the IMV enters into the angle of the confluence of the SV and superior mesenteric vein (SMV) forming the portal vein (PV); 3. the IMV enters the SMV; 4. seven rare variants. We measured the diameters of the veins and distances from the confluence to the IMV origins. Results: The frequency of variants was: 1. 37.6 %, 2. 28.8 %; 3. 19.2 %. The rare variants totaled 14.4 %. The average vessel diameters measured in cm: PV 1.48; SV 1.02; SMV 1.2; IMV 0.5. The mean IMV entering distances were 1.66 cm in variant 1 and 0.75 cm in variant 3. Conclusion: The three common variants (1, 2 and 3) are the most relevant ones. 14.4 % of patients had different anatomic variants. The variability of the mesenteric venous system was higher than previously published. Knowledge of rare variants is important to avoid complications in abdominal surgery. (orig.)

  3. Depiction of variants of the portal confluence venous system using multidetector row CT. Analysis of 916 cases

    International Nuclear Information System (INIS)

    Krumm, P.; Schraml, C.; Bretschneider, C.; Seeger, A.; Klumpp, B.; Kramer, U.; Claussen, C.D.; Miller, S.

    2011-01-01

    Purpose: Detailed knowledge of the venous mesenteric system is important for gastrointestinal surgery, particularly for transplantation planning and surgery and for the comprehension of perioperative complications that may influence patient outcome. Data about the mesenteric venous anatomy in the literature varies substantially. The purpose of this study was to categorize venous mesenteric variants and to determine their incidence. Materials and Methods: We included 916 patients requiring diagnostic abdominal CT in the portal venous phase. The mesenteric vein anatomy was categorized as follows: 1. the inferior mesenteric vein (IMV) enters the splenic vein (SV); 2. the IMV enters into the angle of the confluence of the SV and superior mesenteric vein (SMV) forming the portal vein (PV); 3. the IMV enters the SMV; 4. seven rare variants. We measured the diameters of the veins and distances from the confluence to the IMV origins. Results: The frequency of variants was: 1. 37.6 %, 2. 28.8 %; 3. 19.2 %. The rare variants totaled 14.4 %. The average vessel diameters measured in cm: PV 1.48; SV 1.02; SMV 1.2; IMV 0.5. The mean IMV entering distances were 1.66 cm in variant 1 and 0.75 cm in variant 3. Conclusion: The three common variants (1, 2 and 3) are the most relevant ones. 14.4 % of patients had different anatomic variants. The variability of the mesenteric venous system was higher than previously published. Knowledge of rare variants is important to avoid complications in abdominal surgery. (orig.)

  4. Relation between the left ventricular mass and the left coronary artery dimensions as determined by 16-channel multidetector CT: comparison between the normotensive group and the hypertensive group

    International Nuclear Information System (INIS)

    Kang, Doo Kyung; Park, Kyung Joo; Tahk, Seung Jea; Kim, Sun Yong

    2006-01-01

    The purpose of this study is to determine the left ventricular mass (LVM) and the left coronary artery dimension and to investigate the relationship between the two values in the normotensive group and hypertensive group with using 16-channel multidetector CT (MDCT). Among the patients who underwent a CT coronary angiogram procedure using 16-channel MDCT at Ajou University Hospital from October 2004 to February 2005, 33 patient became the subjects of this study. These 33 patients showed normal findings without calcification or stenosis of the coronary arteries. The total volume of the left ventricular wall was calculated using work-in-progress cardiac CT reconstruction software. The LVM could then be directly calculated by multiplying the left ventricular muscle volume by the myocardial tissue density, which was assumed to be 1.05 g/cm 3 . The coronary diameter was measured by a fixed threshold method from the transverse reformation images obtained along the long-axis of each coronary artery. We calculated the cross-sectional area (CSA) of the coronary arteries from the equation of π D2/4 (D = diameter). Regression analysis was performed for the relationship between LVM and the left coronary artery dimensions with using a linear least-squares method. Comparison between the normotensive group and the hypertensive group was done using the Student test. The average LVM was 127.9 ± 36.2 g (mean ± standard deviation) and the average left ventricular mass index (LVMI) was 74.7 ± 15.5 g in this study population. The average diameter of the coronary arteries was 4.38 ± 0.69 mm for the left coronary artery. In all the subjects (n = 33, r = 0.67, ρ = 0.000) and the normotensive group (n = 21, r = 0.68, ρ = 0.000), the LVM was significantly correlated with the CSA of the left coronary artery, but not in the hypertensive group (n= 12, r = 0.57, ρ = 0.062). In the hypertensive group, the CSA of the left coronary arteries per 100 g of muscle mass tended to decrease as

  5. Diagnostic Value of Multidetector CT and Its Multiplanar Reformation, Volume Rendering and Virtual Bronchoscopy Postprocessing Techniques for Primary Trachea and Main Bronchus Tumors.

    Directory of Open Access Journals (Sweden)

    Mingyue Luo

    Full Text Available To evaluate the diagnostic value of multidetector CT (MDCT and its multiplanar reformation (MPR, volume rendering (VR and virtual bronchoscopy (VB postprocessing techniques for primary trachea and main bronchus tumors.Detection results of 31 primary trachea and main bronchus tumors with MDCT and its MPR, VR and VB postprocessing techniques, were analyzed retrospectively with regard to tumor locations, tumor morphologies, extramural invasions of tumors, longitudinal involvements of tumors, morphologies and extents of luminal stenoses, distances between main bronchus tumors and trachea carinae, and internal features of tumors. The detection results were compared with that of surgery and pathology.Detection results with MDCT and its MPR, VR and VB were consistent with that of surgery and pathology, included tumor locations (tracheae, n = 19; right main bronchi, n = 6; left main bronchi, n = 6, tumor morphologies (endoluminal nodes with narrow bases, n = 2; endoluminal nodes with wide bases, n = 13; both intraluminal and extraluminal masses, n = 16, extramural invasions of tumors (brokethrough only serous membrane, n = 1; 4.0 mm-56.0 mm, n = 14; no clear border with right atelectasis, n = 1, longitudinal involvements of tumors (3.0 mm, n = 1; 5.0 mm-68.0 mm, n = 29; whole right main bronchus wall and trachea carina, n = 1, morphologies of luminal stenoses (irregular, n = 26; circular, n = 3; eccentric, n = 1; conical, n = 1 and extents (mild, n = 5; moderate, n = 7; severe, n = 19, distances between main bronchus tumors and trachea carinae (16.0 mm, n = 1; invaded trachea carina, n = 1; >20.0 mm, n = 10, and internal features of tumors (fairly homogeneous densities with rather obvious enhancements, n = 26; homogeneous density with obvious enhancement, n = 1; homogeneous density without obvious enhancement, n = 1; not enough homogeneous density with obvious enhancement, n = 1; punctate calcification with obvious enhancement, n = 1; low density

  6. Angular on-line tube current modulation in multidetector CT examinations of children and adults: The influence of different scanning parameters on dose reduction

    International Nuclear Information System (INIS)

    Papadakis, Antonios E.; Perisinakis, Kostas; Damilakis, John

    2007-01-01

    The purpose of this study was to assess the potential of angular on-line tube current modulation on dose reduction in pediatric and adult patients undergoing multidetector computed tomography (MDCT) examinations. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-year-old, 5-year-old, 10-year-old, and adult were employed in the current study. Phantoms were scanned with the use of on-line tube current modulation (TCM). Percent dose reduction (%DR) factors achieved by applying TCM, were determined for standard protocols used for head and neck, shoulder, thorax, thorax and abdomen, abdomen, abdomen and pelvis, pelvis, and whole body examinations. A preliminary study on the application of TCM in MDCT examinations of adult patients was performed to validate the results obtained in anthropomorphic phantoms. Dose reduction was estimated as the percentage difference of the modulated milliamperes for each scan and the preset milliamperes prescribed by the scan protocol. The dose reduction in children was found to be much lower than the corresponding reduction achieved for adults. For helical scans the %DR factors, ranged between 1.6% and 7.4% for the neonate, 2.9% and 8.7% for the 1-year old, 2% and 6% for the 5-year-old, 5% and 10.9% for the 10-year-old, and 10.4% and 20.7% for the adult individual. For sequential scans the corresponding %DR factors ranged between 1.3% and 6.7%, 4.5% and 11%, 4.2% and 6.6%, 6.4% and 12.3%, and 8.9% and 23.3%, respectively. Broader beam collimations are associated with decreased %DR factors, when other scanning parameters are held constant. TCM did not impair image noise. In adult patients, the %DR values were found to be in good agreement with the corresponding results obtained in the anthropomorphic adult phantom. In conclusion, on-line TCM may be considered as a valuable tool for reducing dose in routine CT examinations of pediatric and adult patients. However, the dose reduction achieved with TCM

  7. Diagnostic Value of Multidetector CT and Its Multiplanar Reformation, Volume Rendering and Virtual Bronchoscopy Postprocessing Techniques for Primary Trachea and Main Bronchus Tumors.

    Science.gov (United States)

    Luo, Mingyue; Duan, Chaijie; Qiu, Jianping; Li, Wenru; Zhu, Dongyun; Cai, Wenli

    2015-01-01

    To evaluate the diagnostic value of multidetector CT (MDCT) and its multiplanar reformation (MPR), volume rendering (VR) and virtual bronchoscopy (VB) postprocessing techniques for primary trachea and main bronchus tumors. Detection results of 31 primary trachea and main bronchus tumors with MDCT and its MPR, VR and VB postprocessing techniques, were analyzed retrospectively with regard to tumor locations, tumor morphologies, extramural invasions of tumors, longitudinal involvements of tumors, morphologies and extents of luminal stenoses, distances between main bronchus tumors and trachea carinae, and internal features of tumors. The detection results were compared with that of surgery and pathology. Detection results with MDCT and its MPR, VR and VB were consistent with that of surgery and pathology, included tumor locations (tracheae, n = 19; right main bronchi, n = 6; left main bronchi, n = 6), tumor morphologies (endoluminal nodes with narrow bases, n = 2; endoluminal nodes with wide bases, n = 13; both intraluminal and extraluminal masses, n = 16), extramural invasions of tumors (brokethrough only serous membrane, n = 1; 4.0 mm-56.0 mm, n = 14; no clear border with right atelectasis, n = 1), longitudinal involvements of tumors (3.0 mm, n = 1; 5.0 mm-68.0 mm, n = 29; whole right main bronchus wall and trachea carina, n = 1), morphologies of luminal stenoses (irregular, n = 26; circular, n = 3; eccentric, n = 1; conical, n = 1) and extents (mild, n = 5; moderate, n = 7; severe, n = 19), distances between main bronchus tumors and trachea carinae (16.0 mm, n = 1; invaded trachea carina, n = 1; >20.0 mm, n = 10), and internal features of tumors (fairly homogeneous densities with rather obvious enhancements, n = 26; homogeneous density with obvious enhancement, n = 1; homogeneous density without obvious enhancement, n = 1; not enough homogeneous density with obvious enhancement, n = 1; punctate calcification with obvious enhancement, n = 1; low density without

  8. Analysis of 64-row multidetector CT images for preoperative angiographic evaluation of potential living kidney donors; Analyse der mehrphasigen 64-Zeilen-Multidetektor-Computertomographie zur praeoperativen angiographischen Evaluation potenzieller Lebendnierenspender

    Energy Technology Data Exchange (ETDEWEB)

    Blondin, D.; Andersen, K.; Kroepil, P.; Cohnen, M.; Moedder, U.; Jung, G. [Universitaetsklinikum Duesseldorf, Institut fuer Diagnostische Radiologie, Duesseldorf (Germany); Sandmann, W. [Universitaetsklinikum Duesseldorf, Klinik fuer Gefaesschirurgie und Nierentransplantation, Duesseldorf (Germany); Ivens, K. [Universitaetsklinikum Duesseldorf, Klinik fuer Nephrologie, Duesseldorf (Germany)

    2008-07-15

    Anatomical imaging and the ascertainment of any anomalies in the renal vessels and the ureters are essential in the planning of a kidney donation. The aim of the present study was to assess the value of 64-row multidetector CT in noninvasive examination of the renal vessels and ureters of potential living kidney donors. The evaluation embraced 63 living renal donors (LNS) who underwent preoperative CT examination from December 2004 to January 2007. The examinations were all carried out using a Somatom Sensation -Cardiac 64 (Siemens Medical Solutions, Germany). As well as CT angiography (CTA), a venous phase of the abdomen and a late phase after 15 min using low-dose technique were performed for CT urography (CTU). The radiological findings were compared with the surgical results, or with the angiograms in 2 cases. Sensitivity, specificity and both negative and positive predictive value were calculated. In the 63 (31 female, 32 male) donors CTA had a sensitivity of 100% in examination of the main and accessory renal arteries and of 98.3% when the venous and ureteric anatomy were assessed. The sensitivity of low-dose CTU was also 100%. The findings recorded in this study indicate that noninvasive preoperative planning with 64-row multidetector CTA and CTU is a reliable 'one-stop shopping' method of examination for potential living kidney donors. (orig.) [German] Die anatomische Darstellung und Erfassung moeglicher Anomalien der Nierengefaesse und Ureteren ist fuer die Planung einer Lebendnierenspende von essenzieller Bedeutung. Die vorliegende Untersuchung soll die Wertigkeit der nichtinvasiven Evaluation mit der 64-Zeilen-Multidetektor-CT untersuchen. In die Auswertung wurden 63 Lebendnierenspender (LNS) eingeschlossen, die im Zeitraum 12.2004 bis 01.2007 mit der CT praeoperativ untersucht wurden. Die Untersuchungen erfolgten mit einem Somatom-Sensation-Cardiac-64 (Siemens Medical Solutions, Deutschland). Neben einer CT-Angiographie (CTA) wurden eine

  9. The value of "liver windows" settings in the detection of small renal cell carcinomas on unenhanced computed tomography.

    Science.gov (United States)

    Sahi, Kamal; Jackson, Stuart; Wiebe, Edward; Armstrong, Gavin; Winters, Sean; Moore, Ronald; Low, Gavin

    2014-02-01

    To assess if "liver window" settings improve the conspicuity of small renal cell carcinomas (RCC). Patients were analysed from our institution's pathology-confirmed RCC database that included the following: (1) stage T1a RCCs, (2) an unenhanced computed tomography (CT) abdomen performed ≤ 6 months before histologic diagnosis, and (3) age ≥ 17 years. Patients with multiple tumours, prior nephrectomy, von Hippel-Lindau disease, and polycystic kidney disease were excluded. The unenhanced CT was analysed, and the tumour locations were confirmed by using corresponding contrast-enhanced CT or magnetic resonance imaging studies. Representative single-slice axial, coronal, and sagittal unenhanced CT images were acquired in "soft tissue windows" (width, 400 Hounsfield unit (HU); level, 40 HU) and liver windows (width, 150 HU; level, 88 HU). In addition, single-slice axial, coronal, and sagittal unenhanced CT images of nontumourous renal tissue (obtained from the same cases) were acquired in soft tissue windows and liver windows. These data sets were randomized, unpaired, and were presented independently to 3 blinded radiologists for analysis. The presence or absence of suspicious findings for tumour was scored on a 5-point confidence scale. Eighty-three of 415 patients met the study criteria. Receiver operating characteristics (ROC) analysis, t test analysis, and kappa analysis were used. ROC analysis showed statistically superior diagnostic performance for liver windows compared with soft tissue windows (area under the curve of 0.923 vs 0.879; P = .0002). Kappa statistics showed "good" vs "moderate" agreement between readers for liver windows compared with soft tissue windows. Use of liver windows settings improves the detection of small RCCs on the unenhanced CT. Copyright © 2014 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  10. Unenhanced computed tomography in acute renal colic reduces cost outside radiology department

    DEFF Research Database (Denmark)

    Lauritsen, J.; Andersen, J.R.; Nordling, J.

    2008-01-01

    BACKGROUND: Unenhanced multidetector computed tomography (UMDCT) is well established as the procedure of choice for radiologic evaluation of patients with renal colic. The procedure has both clinical and financial consequences for departments of surgery and radiology. However, the financial effect...... outside the radiology department is poorly elucidated. PURPOSE: To evaluate the financial consequences outside of the radiology department, a retrospective study comparing the ward occupation of patients examined with UMDCT to that of intravenous urography (IVU) was performed. MATERIAL AND METHODS......) saved the hospital USD 265,000 every 6 months compared to the use of IVU. CONCLUSION: Use of UMDCT compared to IVU in patients with renal colic leads to cost savings outside the radiology department Udgivelsesdato: 2008/12...

  11. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow new CT scanners to obtain multiple slices in a single rotation. These scanners, called "multislice CT" or "multidetector CT," ...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  14. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  15. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  17. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... membranes covering the brain. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain ...

  19. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... for the moving table. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head ...

  20. Prognostic significance of contrast-enhanced CT attenuation value in extrahepatic cholangiocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Asayama, Yoshiki [Kyushu University, Department of Advanced Imaging and Interventional Radiology, Graduate School of Medical Sciences, Fukuoka (Japan); Nishie, Akihiro; Ishigami, Kousei; Ushijima, Yasuhiro; Takayama, Yukihisa; Okamoto, Daisuke; Fujita, Nobuhiro; Honda, Hiroshi [Kyushu University, Departments of Clinical Radiology, Fukuoka (Japan); Ohtsuka, Takao [Kyushu University, Departments of Surgery and Oncology, Fukuoka (Japan); Yoshizumi, Tomoharu [Kyushu University, Departments of Surgery and Sciences, Fukuoka (Japan); Aishima, Shinichi [Saga University, Pathology and Microbiology, Faculty of Medicine, Saga (Japan); Kyushu University, Departments of Anatomic Pathology, Graduate School of Medical Sciences, Fukuoka (Japan); Oda, Yoshinao [Kyushu University, Departments of Anatomic Pathology, Graduate School of Medical Sciences, Fukuoka (Japan)

    2017-06-15

    To determine whether washout characteristics of dynamic contrast-enhanced computed tomography (CT) could predict survival in patients with extrahepatic cholangiocarcinoma (EHC). This study collected 46 resected cases. All cases were examined by dynamic contrast study on multidetector-row CT. Region-of-interest measurements were obtained at the non-enhanced, portal venous phase and delayed phase in the tumour and were used to calculate the washout ratio as follows: [(attenuation value at portal venous phase CT - attenuation value at delayed enhanced CT)/(attenuation value at portal venous phase CT - attenuation value at unenhanced CT)] x 100. On the basis of the median washout ratio, we classified the cases into two groups, a high-washout group and low-washout group. Associations between overall survival and various factors including washout rates were analysed. The median washout ratio was 29.4 %. Univariate analysis revealed that a lower washout ratio, venous invasion, lymphatic permeation and lymph node metastasis were associated with shorter survival. Multivariate analysis identified the lower washout ratio as an independent prognostic factor (hazard ratio, 3.768; p value, 0.027). The washout ratio obtained from the contrast-enhanced CT may be a useful imaging biomarker for the prediction of survival of patients with EHC. (orig.)

  1. Improvement of Detection of Hypoattenuation in Acute Ischemic Stroke in Unenhanced Computed Tomography Using an Adaptive Smoothing Filter

    International Nuclear Information System (INIS)

    Takahashi, N.; Lee, Y.; Tsai, D. Y.; Ishii, K.; Kinoshita, T.; Tamura, H.; K imura, M.

    2008-01-01

    Background: Much attention has been directed toward identifying early signs of cerebral ischemia on computed tomography (CT) images. Hypoattenuation of ischemic brain parenchyma has been found to be the most frequent early sign. Purpose: To evaluate the effect of a previously proposed adaptive smoothing filter for improving detection of parenchymal hypoattenuation of acute ischemic stroke on unenhanced CT images. Material and Methods: Twenty-six patients with parenchymal hypoattenuation and 49 control subjects without hypoattenuation were retrospectively selected in this study. The adaptive partial median filter (APMF) designed for improving detectability of hypoattenuation areas on unenhanced CT images was applied. Seven radiologists, including four certified radiologists and three radiology residents, indicated their confidence level regarding the presence (or absence) of hypoattenuation on CT images, first without and then with the APMF processed images. Their performances without and with the APMF processed images were evaluated by receiver operating characteristic (ROC) analysis. Results: The mean areas under the ROC curves (AUC) for all observers increased from 0.875 to 0.929 (P=0.002) when the radiologists observed with the APMF processed images. The mean sensitivity in the detection of hypoattenuation significantly improved, from 69% (126 of 182 observations) to 89% (151 of 182 observations), when employing the APMF (P=0.012). The specificity, however, was unaffected by the APMF (P=0.41). Conclusion: The APMF has the potential to improve the detection of parenchymal hypoattenuation of acute ischemic stroke on unenhanced CT images

  2. Multidetector CT: a new gold standard in the diagnosis of pulmonary embolism? State of the art and diagnostic algorithms; La TC multitettore: il nuovo gold standard nella diagnosi di embolia polmonare? Stato dell'arte e algoritmi diagnostici

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Vincenzo; Piva, Tommaso; Lovato, Luigi; Fattori, Rossella; Gavelli, Giampaolo [Policlinico S. Orsola, Bologna (Italy). Dipartimento di Radiologia Radiologia III

    2005-02-01

    Purpose: From the early 90s, spiral CT technology has considerably changed the diagnostic capability of Pulmonary Embolism (PE), giving a direct vision of intravascular thrombi. Further technological progress has straightened its diagnostic impact leading to an essential role in clinical practice. The advent of Multi-Detector CT (MDCT) has subsequently increased the reliability of this technique to the point of undermining the role of pulmonary angiography as the gold standard and occupying a central position in diagnostic algorithms. The aim of this paper is to appraise this evolution by means of a meta-analysis of the relevant literature from 1995 to 2004. Results: The review of the literature showed the sensitivity and specificity of CT to have increased from 37-94% and 91-100% (single detector CT) to 87-94% and 94-100% (4-channel multidetector CT), especially thanks to the possibility of depicting subsegmental clots, with an interobserver agreement of 0.63-0.94 (k). Conclusions: CT is one of the most reliable and effective methods in the diagnosis is PE, with the advantage of being extremely fast and providing alternative diagnoses. Recent improvements in MDCT technology confers the highest value of diagnostic accuracy with respect to other imaging modalities such as scintigraphy, angiography, MRI, D-dimer essay and Doppler US. [Italian] Scopo: Dall'inizio degli anni '90, la tecnologia TC spirale (TCS) ha cambiato notevolmente la capacita' diagnostica di Embolia Polmonare (EP), fornendo una visione diretta dei trombi endoluminali. Successivi progressi tecnologici hanno fortificato il suo impatto diagnostico a tal punto che questa metodica e' ora essenziale nella pratica clinica. L'avvento della TC Multi-Detettore (TCMD) ha aumentato di conseguenza l'affidabilita' di questa tecnica fino a tal punto da scalzare l'angiopneumografia dal ruolo di Gold Standard ed occupare una posizione cantrale negli algoritmi diagnostici

  3. Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT : an anthropomorphic phantom study

    NARCIS (Netherlands)

    Xie, X.; Zhao, Yingru; Snijder, R.A.; van Ooijen, P.M.; de Jong, P.A.; Oudkerk, M.; de Bock, G.H.; Vliegenthart, R.; Greuter, M.J.

    To assess the sensitivity of detection and accuracy of volumetry by manual and semi-automated quantification of artificial pulmonary nodules in an anthropomorphic thoracic phantom on low-dose CT. Fifteen artificial spherical nodules (diameter 3, 5, 8, 10 and 12 mm; CT densities -800, -630 and +100

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called "multislice CT" or "multidetector CT," ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  5. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Using a multidetector CT unit to examine ... CT scans should have no immediate side effects. Risks The risk of serious allergic reaction to contrast ...

  6. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Using a multidetector CT unit to examine children ... scanning is painless, noninvasive and accurate. A major advantage of CT is its ability to image bone, ...

  7. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called "multislice CT" or "multidetector CT," ... best for your child. top of page Additional Information and Resources The Alliance for Radiation Safety in ...

  8. The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations

    Science.gov (United States)

    Gu, J.; Bednarz, B.; Caracappa, P. F.; Xu, X. G.

    2009-05-01

    The latest multiple-detector technologies have further increased the popularity of x-ray CT as a diagnostic imaging modality. There is a continuing need to assess the potential radiation risk associated with such rapidly evolving multi-detector CT (MDCT) modalities and scanning protocols. This need can be met by the use of CT source models that are integrated with patient computational phantoms for organ dose calculations. Based on this purpose, this work developed and validated an MDCT scanner using the Monte Carlo method, and meanwhile the pregnant patient phantoms were integrated into the MDCT scanner model for assessment of the dose to the fetus as well as doses to the organs or tissues of the pregnant patient phantom. A Monte Carlo code, MCNPX, was used to simulate the x-ray source including the energy spectrum, filter and scan trajectory. Detailed CT scanner components were specified using an iterative trial-and-error procedure for a GE LightSpeed CT scanner. The scanner model was validated by comparing simulated results against measured CTDI values and dose profiles reported in the literature. The source movement along the helical trajectory was simulated using the pitch of 0.9375 and 1.375, respectively. The validated scanner model was then integrated with phantoms of a pregnant patient in three different gestational periods to calculate organ doses. It was found that the dose to the fetus of the 3 month pregnant patient phantom was 0.13 mGy/100 mAs and 0.57 mGy/100 mAs from the chest and kidney scan, respectively. For the chest scan of the 6 month patient phantom and the 9 month patient phantom, the fetal doses were 0.21 mGy/100 mAs and 0.26 mGy/100 mAs, respectively. The paper also discusses how these fetal dose values can be used to evaluate imaging procedures and to assess risk using recommendations of the report from AAPM Task Group 36. This work demonstrates the ability of modeling and validating an MDCT scanner by the Monte Carlo method, as well as

  9. The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations

    International Nuclear Information System (INIS)

    Gu, J; Bednarz, B; Caracappa, P F; Xu, X G

    2009-01-01

    The latest multiple-detector technologies have further increased the popularity of x-ray CT as a diagnostic imaging modality. There is a continuing need to