WorldWideScience

Sample records for underwent standard procedures

  1. Effects of adding Braun jejunojejunostomy to standard Whipple procedure on reduction of afferent loop syndrome - a randomized clinical trial.

    Science.gov (United States)

    Kakaei, Farzad; Beheshtirouy, Samad; Nejatollahi, Seyed Moahammad Reza; Rashidi, Iqbal; Asvadi, Touraj; Habibzadeh, Afshin; Oliaei-Motlagh, Mohammad

    2015-12-01

    Whipple surgery (pancreaticodeudenectomy) has a high complication rate. We aimed to evaluate whether adding Braun jejunojejunostomy (side-to-side anastomosis of afferent and efferent loops distal to the gastrojejunostomy site) to a standard Whipple procedure would reduce postoperative complications. We conducted a randomized clinical trial comparing patients who underwent standard Whipple surgery (standard group) and patients who underwent standard Whipple surgery with Braun jejunojejunostomy (Braun group). Patients were followed for 1 month after the procedure and postoperative complications were recorded. Our study included 30 patients: 15 in the Braun and 15 in the standard group. In the Braun group, 4 (26.7%) patients experienced 6 complications, whereas in the standard group, 7 (46.7%) patients experienced 11 complications (p = 0.14). Complications in the Braun group were gastrointestinal bleeding and wound infection (n = 1 each) and delayed gastric emptying and pulmonary infection (n = 2 each). Complications in the standard group were death, pancreatic anastomosis leak and biliary anastomosis leak (n = 1 each); gastrointestinal bleeding (n = 2); and afferent loop syndrome and delayed gastric emptying (n = 3 each). There was no significant difference between groups in the subtypes of complications. Our results showed that adding Braun jejunojejunostomy to standard Whipple procedure was associated with lower rates of afferent loop syndrome and delayed gastric emptying. However, more studies are needed to define the role of Braun jejunojejunostomy in this regard. IRCT2014020316473N1 (www.irct.ir).

  2. Radiation control standards and procedures

    Energy Technology Data Exchange (ETDEWEB)

    1956-12-14

    This manual contains the Radiation Control Standards'' and Radiation Control Procedures'' at Hanford Operations which have been established to provide the necessary control radiation exposures within Irradiation Processing Department. Provision is also made for including, in the form of Bulletins'', other radiological information of general interest to IPD personnel. The purpose of the standards is to establish firm radiological limits within which the Irradiation Processing Department will operate, and to outline our radiation control program in sufficient detail to insure uniform and consistent application throughout all IPD facilities. Radiation Control Procedures are intended to prescribe the best method of accomplishing an objective within the limitations of the Radiation Control Standards. A procedure may be changed at any time provided the suggested changes is generally agreeable to management involved, and is consistent with department policies and the Radiation Control Standards.

  3. 18 CFR 725.6 - Principles, standards and procedures.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Principles, standards... Responsibilities § 725.6 Principles, standards and procedures. The Principles, Standards and Procedures established... Orders. These Principles, Standards and Procedures are found in 18 CFR parts 710 through 717. ...

  4. 21 CFR 120.6 - Sanitation standard operating procedures.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Sanitation standard operating procedures. 120.6... Provisions § 120.6 Sanitation standard operating procedures. (a) Sanitation controls. Each processor shall have and implement a sanitation standard operating procedure (SSOP) that addresses sanitation...

  5. "Heidelberg standard examination" and "Heidelberg standard procedures" - Development of faculty-wide standards for physical examination techniques and clinical procedures in undergraduate medical education.

    Science.gov (United States)

    Nikendei, C; Ganschow, P; Groener, J B; Huwendiek, S; Köchel, A; Köhl-Hackert, N; Pjontek, R; Rodrian, J; Scheibe, F; Stadler, A-K; Steiner, T; Stiepak, J; Tabatabai, J; Utz, A; Kadmon, M

    2016-01-01

    The competent physical examination of patients and the safe and professional implementation of clinical procedures constitute essential components of medical practice in nearly all areas of medicine. The central objective of the projects "Heidelberg standard examination" and "Heidelberg standard procedures", which were initiated by students, was to establish uniform interdisciplinary standards for physical examination and clinical procedures, and to distribute them in coordination with all clinical disciplines at the Heidelberg University Hospital. The presented project report illuminates the background of the initiative and its methodological implementation. Moreover, it describes the multimedia documentation in the form of pocketbooks and a multimedia internet-based platform, as well as the integration into the curriculum. The project presentation aims to provide orientation and action guidelines to facilitate similar processes in other faculties.

  6. 40 CFR 160.81 - Standard operating procedures.

    Science.gov (United States)

    2010-07-01

    .... (10) Data handling, storage and retrieval. (11) Maintenance and calibration of equipment. (12... GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 160.81 Standard operating procedures... test, control, and reference substances. (4) Test system observations. (5) Laboratory or other tests...

  7. Standardized procedure for tsunami PRA by AESJ

    International Nuclear Information System (INIS)

    Kirimoto, Yukihiro; Yamaguchi, Akira; Ebisawa, Katsumi

    2013-01-01

    After Fukushima Accident (March 11, 2011), the Atomic Energy Society of Japan (AESJ) started to develop the standard of Tsunami Probabilistic Risk Assessment (PRA) for nuclear power plants in May 2011. As Japan is one of the countries with frequent earthquakes, a great deal of efforts has been made in the field of seismic research since the early stage. To our regret, the PRA procedures guide for tsunami has not yet been developed although the importance is held in mind of the PRA community. Accordingly, AESJ established a standard to specify the standardized procedure for tsunami PRA considering the results of investigation into the concept, the requirements that should have and the concrete methods regarding tsunami PRA referring the opinions of experts in the associated fields in December 2011 (AESJ-SC-RK004:2011). (author)

  8. Standard Operating Procedure for Accelerated Corrosion Testing at ARL

    Science.gov (United States)

    2017-11-01

    ARL-TN-0855 ● NOV 2017 US Army Research Laboratory Standard Operating Procedure for Accelerated Corrosion Testing at ARL by... Corrosion Testing at ARL by Thomas A Considine Weapons and Materials Research Directorate, ARL Approved for public...November 2017 2. REPORT TYPE Technical Note 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Standard Operating Procedure for Accelerated

  9. The European Stroke Organisation Guidelines: a standard operating procedure

    DEFF Research Database (Denmark)

    Ntaios, George; Bornstein, Natan M; Caso, Valeria

    2015-01-01

    pace with this progress and driven by the strong determination of the European Stroke Organisation to further promote stroke management, education, and research, the European Stroke Organisation decided to delineate a detailed standard operating procedure for its guidelines. There are two important...... cornerstones in this standard operating procedure: The first is the implementation of the Grading of Recommendations Assessment, Development, and Evaluation methodology for the development of its Guideline Documents. The second one is the decision of the European Stroke Organisation to move from the classical...... and significant input from European Stroke Organisation members as well as methodologists and analysts, this document presents the official standard operating procedure for the development of the Guideline Documents of the European Stroke Organisation....

  10. Standard interface files and procedures for reactor physics codes. Version IV

    International Nuclear Information System (INIS)

    O'Dell, R.D.

    1977-09-01

    Standards, procedures, and recommendations of the Committee on Computer Code Coordination for promoting the exchange of reactor physics codes are updated to Version IV status. Standards and procedures covering general programming, program structure, standard interface files, and file management and handling subroutines are included

  11. Using a standards committee to design practical procedure system improvements

    International Nuclear Information System (INIS)

    Grider, D.A.; Plung, D.

    1993-01-01

    In the post-Three Mile Island (TMI) environment, numerous reports have been issued on how to improve the quality of procedures used at government and commercial nuclear facilities. The studies tend to be long on what is wrong with existing procedures and short on practical directions on how to fix those faults. Few of these studies have been conducted by practitioners with full-time procedure-managing or procedure writing experience. None of these studies go into detail on how to improve the procedure system itself. Over the last 10 yr, various nuclear facilities within the US Department of Energy (DOE) have carried out individual programs to develop procedures that meet post-TMI standards. However, ∼2 yr ago, DOE formed a Procedures Standards Committee to advise DOE in developing a set of post-TMI guidelines that could be consistently applied throughout all DOE nuclear facilities. The committee has achieved not only its original mission by producing a series of integrated guidance documents but has also evolved a systems approach to procedures management that sets new standards for procedure quality and efficiency. As members of this committee, the authors want to describe what has made the group's approach so successful. The lessons learned may be translatable to a wide range of government and commercial industry procedure programs

  12. Standard Review Plan Maintenance Program implementing procedures document

    International Nuclear Information System (INIS)

    1996-11-01

    The implementing Procedures Document (IPD) was developed by the Inspection Program Projects Branch, Office of Nuclear Reactor Regulation, with assistance from Pacific Northwest National Laboratory, for the Standard Review Plan Maintenance Program (SRP-MP). The SRP-MP was established to maintain the Standard Review Plan (SRP) on an on-going basis. The IPD provides guidance, including an overall approach and procedures, for SRP-MP tasks. The objective of the IPD is to ensure that modifications to SRP need to reflect current NRC requirements and guidance are identified and that a consistent methodology is used to develop and revise SRP sections

  13. Procedures and Standards Handbook. Version 3.0. What Works Clearinghouse

    Science.gov (United States)

    What Works Clearinghouse, 2014

    2014-01-01

    This "What Works Clearinghouse Procedures and Standards Handbook (Version 3.0)" provides a detailed description of the standards and procedures of the What Works Clearinghouse (WWC). The remaining chapters of this Handbook are organized to take the reader through the basic steps that the WWC uses to develop a review protocol, identify…

  14. Standards for radiation protection instrumentation: design of safety standards and testing procedures

    International Nuclear Information System (INIS)

    Meissner, Frank

    2008-01-01

    This paper describes by means of examples the role of safety standards for radiation protection and the testing and qualification procedures. The development and qualification of radiation protection instrumentation is a significant part of the work of TUV NORD SysTec, an independent expert organisation in Germany. The German Nuclear Safety Standards Commission (KTA) establishes regulations in the field of nuclear safety. The examples presented may be of importance for governments and nuclear safety authorities, for nuclear operators and for manufacturers worldwide. They demonstrate the advantage of standards in the design of radiation protection instrumentation for new power plants, in the upgrade of existing instrumentation to nuclear safety standards or in the application of safety standards to newly developed equipment. Furthermore, they show how authorities may proceed when safety standards for radiation protection instrumentation are not yet established or require actualization. (author)

  15. Serum Zn levels in dysphagic patients who underwent endoscopic gastrostomy for long term enteral nutrition

    OpenAIRE

    Adriana Santos, Carla; Fonseca, Jorge; Brito, José; Fernandes, Tânia; Gonçalves, Luísa; Sousa Guerreiro, António

    2014-01-01

    Background and aims: Dysphagic patients who underwent endoscopic gastrostomy (PEG) usually present protein-energy malnutrition, but little is known about micronutrient malnutrition. The aim of the present study was the evaluation of serum zinc in patients who underwent endoscopic gastrostomy and its relationship with serum proteins, whole blood zinc, and the nature of underlying disorder. Methods: From patients that underwent gastrostomy a blood sample was obtained minutes before the procedur...

  16. Trends and the determination of effective doses for standard X-ray procedures

    International Nuclear Information System (INIS)

    Johnson, H.M.; Neduzak, C.; Gallet, J.; Sandeman, J.

    2001-01-01

    Trends in the entrance skin exposures (air kerma) for standard x-ray imaging procedures are reported for the Province of Manitoba, Canada. Average annual data per procedure using standard phantoms and standard ion chambers have been recorded since 1981. For example, chest air kerma (backscatter included) has decreased from 0.14 to 0.09 mGy. Confounding factors may negate the gains unless facility quality control programs are maintained. The data were obtained for a quality assurance and regulatory compliance program. Quoting such data for risk evaluation purposes lacks rigor hence a compartment model for organ apportioning, using organ absorbed doses and weighting factors, has been applied to determine effective dose per procedure. The effective doses for the standard procedures are presented, including the value of 0.027 mSv (1999) calculated for the effective dose in PA chest imaging. (author)

  17. Gadolinium Use in Spine Pain Management Procedures for Patients with Contrast Allergies: Results in 527 Procedures

    International Nuclear Information System (INIS)

    Safriel, Yair; Ang, Roberto; Ali, Muhammed

    2008-01-01

    Introduction. To review the safety and efficacy of gadolinium in spine pain management procedures in patients at high risk for a contrast reaction and who are not suitable candidates for the use of standard non-ionic contrast. Methods. We reviewed records over a 61-month period of all image-guided spinal pain management procedures where patients had allergies making them unsuitable candidates for standard non-ionic contrast and where gadolinium was used to confirm needle tip placement prior to injection of medication. Results. Three hundred and four outpatients underwent 527 procedures. A spinal needle was used in all but 41 procedures. Gadolinium was visualized using portable C-arm fluoroscopy in vivo allowing for confirmation of needle tip location. The gadolinium dose ranged from 0.2 to 10 ml per level. The highest dose received by one patient was 15.83 ml intradiscally during a three-level discogram. Three hundred and one patients were discharged without complication or known delayed complications. One patient had documented intrathecal injection but without sequelae and 2 patients who underwent cervical procedures experienced seizures requiring admission to the intensive care unit. Both the latter patients were discharged without any further complications. Conclusion. Based on our experience we recommend using gadolinium judiciously for needle tip confirmation. We feel more confident using gadolinium in the lumbar spine and in cervical nerve blocks. Gadolinium should probably not be used as an injectate volume expander. The indications for gadolinium use in cervical needle-guided spine procedures are less clear and use of a blunt-tipped needle should be considered

  18. From guidelines to standards of care for open tibial fractures.

    Science.gov (United States)

    Trickett, R W; Rahman, S; Page, P; Pallister, I

    2015-09-01

    The standards for the management of open fractures of the lower limb published by the British Association of Plastic, Reconstructive and Aesthetic surgeons (BAPRAS) and British Orthopaedic Association (BOA) were introduced to improve the treatment received by patients after open injury to the lower limb. These Standards were released after BAPRAS/BOA published Guidelines for the management of open tibial fractures. We wished to determine the impact of these Standards upon the surgical management of open tibial fractures by comparing patients admitted to an orthoplastic centre in the 45 months concluding December 2009 (the Guidelines era) with those admitted during 2011 (the Standards era). Surgical procedures required during the first 30 days and 12 months after injury were determined. Cases were divided into 'directly admitted patients' (DAP) and 'transferred patients' (TP). Standards-era patients were divided further into those who had surgery exclusively at the orthoplastic centre (orthoplastic patients (OPP)) and those transferred after surgery (TASP). The number of TP trebled in frequency in the Standards era, 25% of whom were transferred before surgery. Significantly fewer surgical procedures were required for DAP and OPP groups compared with TP (and TASP) groups in both eras (Mann-Whitney U-test, p=0.05). DAP and OPP groups during the Standards era underwent the fewest procedures, with the vast majority of cases treated with two or fewer procedures in the first 12 months (88% and 80%, respectively, compared with 61% in the Guidelines era). In the Guidelines era, 44% of TP cases and in the Standards era 39% of TP and 29% of TASP groups underwent two or fewer procedures. Approximately two-thirds of open tibial fractures managed in our orthoplastic centre were patients transferred after surgery. The greatest impact of the Standards was evident for those who underwent surgery exclusively in the orthoplastic centre, reflecting a more deliberate combined strategy

  19. Standard Ship Test and Inspection Plan, Procedures and Database

    National Research Council Canada - National Science Library

    1999-01-01

    ... construction schedules and increased cost is the area of test and inspection. This project investigates existing rules and regulations for testing and inspection of commercial ships and identifies differences and similarities within the requirements. The results include comparison matrices, a standard test plan, a set of standard test procedures, and a sample test database developed for a typical commercial ship.

  20. The implementation of a standardized approach to laparoscopic rectal surgery

    DEFF Research Database (Denmark)

    Aslak, Katrine Kanstrup; Bulut, Orhan

    2012-01-01

    BACKGROUND AND OBJECTIVES: The purpose of this study was to audit our results after implementation of a standardized operative approach to laparoscopic surgery for rectal cancer within a fast-track recovery program. METHODS: From January 2009 to February 2011, 100 consecutive patients underwent...... laparoscopic surgery on an intention-to-treat basis for rectal cancer. The results were retrospectively reviewed from a prospectively collected database. Operative steps and instrumentation for the procedure were standardized. A standard perioperative care plan was used. RESULTS: The following procedures were...

  1. 10 CFR 440.21 - Weatherization materials standards and energy audit procedures.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Weatherization materials standards and energy audit... FOR LOW-INCOME PERSONS § 440.21 Weatherization materials standards and energy audit procedures. (a...) of this section describes the performance and quality standards for renewable energy systems...

  2. Standardization of the time for the execution of HANARO start-up and shutdown procedures

    International Nuclear Information System (INIS)

    Choi, H. Y.; Lim, I. C.; Hwang, S. R.; Kang, T. J.; Youn, D. B.

    2003-01-01

    For the standardization of the time to execute HANARO start-up and shutdown procedures, code names were assigned to the individual procedures and the work time were investigated. The data recorded by the operators during start-up and shutdown were statistically analyzed. The analysis results will be used for the standardization of start-up and shutdown procedures and it will be reflected in the procedure document

  3. Megarectumsigma underwent surgery for chronic faecal impact action

    International Nuclear Information System (INIS)

    Canessa, C.; Gomez del Valle, M.; Caraballo, M.

    2002-01-01

    Seven patients with megarectumsigma underwent surgery for chronic faecal impaction,reviewing clinical diagnosis, aetiology and medical and surgical management.It is suggested medical management of chronic faecal impaction trying to achieve elective surgery.The curative surgery should include the resection of all pathologic bowel, but in Duhamel procedure and its modifications distal rectal tran section should be at the peritoneal reflection.Habr-Gama modification has shown to be technically easier and it has been communicated good functional results.Local unfavourable conditions may be resolve by staged surgery,which allows outline definitive bowel reconstruction after functional assessment

  4. Procedures and Standards for Residential Ventilation System Commissioning: An Annotated Bibliography

    Energy Technology Data Exchange (ETDEWEB)

    Stratton, J. Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wray, Craig P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-04-01

    Beginning with the 2008 version of Title 24, new homes in California must comply with ANSI/ASHRAE Standard 62.2-2007 requirements for residential ventilation. Where installed, the limited data available indicate that mechanical ventilation systems do not always perform optimally or even as many codes and forecasts predict. Commissioning such systems when they are installed or during subsequent building retrofits is a step towards eliminating deficiencies and optimizing the tradeoff between energy use and acceptable IAQ. Work funded by the California Energy Commission about a decade ago at Berkeley Lab documented procedures for residential commissioning, but did not focus on ventilation systems. Since then, standards and approaches for commissioning ventilation systems have been an active area of work in Europe. This report describes our efforts to collect new literature on commissioning procedures and to identify information that can be used to support the future development of residential-ventilation-specific procedures and standards. We recommend that a standardized commissioning process and a commissioning guide for practitioners be developed, along with a combined energy and IAQ benefit assessment standard and tool, and a diagnostic guide for estimating continuous pollutant emission rates of concern in residences (including a database that lists emission test data for commercially-available labeled products).

  5. Standard Review Plan Update and Development Program. Implementing Procedures Document

    Energy Technology Data Exchange (ETDEWEB)

    1992-05-01

    This implementing procedures document (IPD) was prepared for use in implementing tasks under the standard review plan update and development program (SRP-UDP). The IPD provides comprehensive guidance and detailed procedures for SRP-UDP tasks. The IPD is mandatory for contractors performing work for the SRP-UDP. It is guidance for the staff. At the completion of the SRP-UDP, the IPD will be revised (to remove the UDP aspects) and will replace NRR Office Letter No. 800 as long-term maintenance procedures.

  6. Standardization of SMP procedure and its impact on outcome

    Directory of Open Access Journals (Sweden)

    Rachita S Dhurat

    2017-01-01

    Full Text Available Background: Cosmetic deformities can result from various types of alopecia or even post hair transplantation procedures. Patients with such deformities seek aesthetically appealing longer-lasting options. Scalp concealers are commonly used by men and women to camouflage these deformities. Scalp micropigmentation (SMP is one of the concealers recently gaining popularity. Objectives: SMP is a novel technique wherein microdot tattoos are placed in a stippling pattern to mimic hair follicles that are cut close to the scalp and various variables affecting its outcome were evaluated. Methods: Forty-five subjects were recruited for the study. The various factors affecting outcome of SMP—angle of needle against the scalp, depth of needle into the scalp, time of the needle contact in scalp, speed of the rotor, resistance of scalp, color of pigment, viscosity of dye, needle number, needle thickness, and pattern of dot placement—were systematically studied in 15 patients through clinical photographs and trichoscopy. Ideal depth of pigment deposition was assessed through histopathological examination. After using these optimum variables, standardized SMP was performed in 30 patients with hair loss (3 patients with cicatricial and 27 patients with diffuse non-cicatricial alopecia. SMP was also used to create an aesthetically denser hairline. The outcome of the procedure was evaluated using standardized global photographs. Results: The ideal parameters were established to achieve standard reproducible results. There were great patient satisfaction and acceptance of the procedure. All the patients showed moderate to great improvement after the procedure with satisfactory scalp coverage. Adverse events were transient which were seen in the form of edema and redness. Conclusion: SMP offers a non-medical, tattoo-based cosmetically appealing and effective “cover-up” that hides the unsightly conditions. The cosmetic tattoo placement creates an illusion of

  7. EVALUASI SANITATION STANDARD OPERATING PROCEDURES KERUPUKAMPLANG DI UD SARINA KECAMATAN KALIANGET KABUPATEN SUMENEP

    Directory of Open Access Journals (Sweden)

    Ach Triharjono

    2016-11-01

    Full Text Available Industri pangan untuk menghasilkan produk yang memenuhi standar keamanan pangan. Standar tersebut dapat dipenuhi dengan menerapkan 8 aspek kunci Sanitation Standard Operating Prosedures (SSOP. Tujuan dari penelitian ini adalah untuk memperoleh hasil penerapan 8 aspek kunci Sanitation Standard Operating Procedures (SSOP dan mengevaluasi penerapan Sanitation Standard Operating Procedures (SSOP Di UD Sarina Kecamatan Kalianget Kabupaten Sumenep. Jenis penelitian ini bersifat deskriptif dengan lokasi penelitian di UD Sarina Kecamatan Kalianget Kabupaten Sumenep. Hasil penelitian diketahui bahwa penerapan 8 aspek kunci Sanitation Standard Operating Procedures (SSOP di UD Sarina sudah terlaksana tapi terdapat 3 tahapan kunci yang belum terlaksana dengan baik yaitu pencegahan kontaminasi silang, pengawasan kondisi kesehatan personil dan menghilangkan hama dari unit pengolahan. Hal yang perlu ditingkatkan terkait dengan penerapan SSOP di UD Sarina yaitu masih perlu adanya manual prosedur untuk berbagai pelaksanaan sanitasi yang dilakukan oleh UD Sarina ini

  8. 40 CFR 75.38 - Standard missing data procedures for Hg CEMS.

    Science.gov (United States)

    2010-07-01

    ... Hg CEMS. 75.38 Section 75.38 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED... Standard missing data procedures for Hg CEMS. (a) Once 720 quality assured monitor operating hours of Hg... substitute data for Hg concentration in accordance with the procedures in ( 75.33(b)(1) through (b)(4...

  9. 75 FR 72942 - Standard Instrument Approach Procedures, and Takeoff Minimums and Obstacle Departure Procedures...

    Science.gov (United States)

    2010-11-29

    ...: Harry J. Hodges, Flight Procedure Standards Branch (AFS-420), Flight Technologies and Programs Divisions..., SD, Rapid City Rgnl, ILS OR LOC RWY 32, Amdt 19 Newport News, VA, Newport News/Williamsburg Intl, ILS OR LOC RWY 7, Amdt 33 Newport News, VA, Newport News/Williamsburg Intl, ILS OR LOC RWY 25, Amdt 1...

  10. Standard procedures for adults in accredited sleep medicine centres in Europe

    DEFF Research Database (Denmark)

    Fischer, Jürgen; Dogas, Zoran; Bassetti, Claudio L

    2012-01-01

    The present paper describes standardized procedures within clinical sleep medicine. As such, it is a continuation of the previously published European guidelines for the accreditation of sleep medicine centres and European guidelines for the certification of professionals in sleep medicine, aimed...... at creating standards of practice in European sleep medicine. It is also part of a broader action plan of the European Sleep Research Society, including the process of accreditation of sleep medicine centres and certification of sleep medicine experts, as well as publishing the Catalogue of Knowledge...... and Skills for sleep medicine experts (physicians, non-medical health care providers, nurses and technologists), which will be a basis for the development of relevant educational curricula. In the current paper, the standard operational procedures sleep medicine centres regarding the diagnostic...

  11. Experimental verification for standard analysis procedure of 241Am in food

    International Nuclear Information System (INIS)

    Liu Qingfen; Zhu Hongda; Liu Shutian; Pan Jingshun; Yang Dating

    2005-01-01

    Objective: The briefly experimental verification for 'determination of 241 Am in food' has been described. Methods: The overall recovery, the MDL of method and decontamination experiment has been done by standard analysis procedure. Results: The overall recovery is 76.26 ± 4.1%. The MDL is 3.4 x 10 -5 Bq/g ash, decontamination factor is higher than 10 3 for Po, 10 2 for U, Th, Pu and 60 for 237 Np. Conclusion: The results showed that the overall recovery is quite high and reliable, the MDL of method is able to meet examining 241 Am limited values in foods. the obtained decontamination factors of recommended procedure can meet analysis of 241 Am in food examination. Venifying results of the procedure are satisfied by using 243 Am spike and 241 Am standard reference material. (authors)

  12. Standardized methods for photography in procedural dermatology using simple equipment.

    Science.gov (United States)

    Hexsel, Doris; Hexsel, Camile L; Dal'Forno, Taciana; Schilling de Souza, Juliana; Silva, Aline F; Siega, Carolina

    2017-04-01

    Photography is an important tool in dermatology. Reproducing the settings of before photos after interventions allows more accurate evaluation of treatment outcomes. In this article, we describe standardized methods and tips to obtain photographs, both for clinical practice and research procedural dermatology, using common equipment. Standards for the studio, cameras, photographer, patients, and framing are presented in this article. © 2017 The International Society of Dermatology.

  13. Poor compliance with standard precautions against infections during minor gynaecological procedures.

    Science.gov (United States)

    Maharaj, Dushyant; Lawton, Beverley; Garrett, Sue

    2012-06-01

    Splash injuries occurring during minor surgical procedures are associated with a significant infective risk to the operator. It is a common misconception that minor operations carry low risks. To determine the prevalence of the practice of Standard Precautions by medical staff in the obstetric and gynaecology (O & G) units of two hospitals in New Zealand, and to assess self-observed splash injury rates. A cross-sectional survey of all doctors working in the O & G units of two public hospitals servicing a population of 435 000. A self-administered questionnaire was provided to 43 doctors with questions related to the use of Standard Precautions, perceived likelihood of infection from a splash and splash injuries sustained during procedures. The response rate was 76.6% (n = 33/43). Of the respondents, only 30.3% (n = 10) used Standard Precautions during minor procedures. Sixty-four per cent (n = 21) routinely used goggles/visor for eye protection. Forty-five per cent (n = 15) thought they were likely to get an infection from a splash, and 55% (n = 18) of clinicians had experienced a splash injury. Of the minor procedures during which splash injuries had occurred, repair of episiotomy 45.8% (n = 11) was the commonest. This survey shows poor compliance with guidelines for Standard Precautions to protect from infection despite self-reported rates of splash injury being high at 55%. Effective interventions are needed to increase compliance and prevent infection. © 2012 The Authors ANZJOG © 2012 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  14. A Comparison of Standard-Setting Procedures for an OSCE in Undergraduate Medical Education.

    Science.gov (United States)

    Kaufman, David M.; Mann, Karen V.; Muijtjens, Arno M. M.; van der Vleuten, Cees P. M.

    2000-01-01

    Compared four standard-setting procedures for an objective structure clinical examination (OSCE) in medical education. Applied Angoff, borderline, relative, and holistic procedures to the data used to establish a cutoff score for a pass/fail decision. The Angoff and borderline procedures gave similar results; however, the relative and holistic…

  15. Evolution of elderly patients who underwent cardiac surgery with cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Alain Moré Duarte

    2016-01-01

    Full Text Available Introduction: There is a steady increase in the number of elderly patients with severe cardiovascular diseases who require a surgical procedure to recover some quality of life that allows them a socially meaningful existence, despite the risks.Objectives: To analyze the behavior of elderly patients who underwent cardiac surgery with cardiopulmonary bypass.Method: A descriptive, retrospective, cross-sectional study was conducted with patients over 65 years of age who underwent surgery at the Cardiocentro Ernesto Che Guevara, in Santa Clara, from January 2013 to March 2014.Results: In the study, 73.1% of patients were men; and there was a predominance of subjects between 65 and 70 years of age, accounting for 67.3%. Coronary artery bypass graft was the most prevalent type of surgery and had the longest cardiopulmonary bypass times. Hypertension was present in 98.1% of patients. The most frequent postoperative complications were renal dysfunction and severe low cardiac output, with 44.2% and 34.6% respectively.Conclusions: There was a predominance of men, the age group of 65 to 70 years, hypertension, and patients who underwent coronary artery bypass graft with prolonged cardiopulmonary bypass. Renal dysfunction was the most frequent complication.

  16. Improving the safety and quality of nursing care through standardized operating procedures in Bosnia and Herzegovina.

    Science.gov (United States)

    Ausserhofer, Dietmar; Rakic, Severin; Novo, Ahmed; Dropic, Emira; Fisekovic, Eldin; Sredic, Ana; Van Malderen, Greet

    2016-06-01

    We explored how selected 'positive deviant' healthcare facilities in Bosnia and Herzegovina approach the continuous development, adaptation, implementation, monitoring and evaluation of nursing-related standard operating procedures. Standardized nursing care is internationally recognized as a critical element of safe, high-quality health care; yet very little research has examined one of its key instruments: nursing-related standard operating procedures. Despite variability in Bosnia and Herzegovina's healthcare and nursing care quality, we assumed that some healthcare facilities would have developed effective strategies to elevate nursing quality and safety through the use of standard operating procedures. Guided by the 'positive deviance' approach, we used a multiple-case study design to examine a criterion sample of four facilities (two primary healthcare centres and two hospitals), collecting data via focus groups and individual interviews. In each studied facility, certification/accreditation processes were crucial to the initiation of continuous development, adaptation, implementation, monitoring and evaluation of nursing-related SOPs. In one hospital and one primary healthcare centre, nurses working in advanced roles (i.e. quality coordinators) were responsible for developing and implementing nursing-related standard operating procedures. Across the four studied institutions, we identified a consistent approach to standard operating procedures-related processes. The certification/accreditation process is enabling necessary changes in institutions' organizational cultures, empowering nurses to take on advanced roles in improving the safety and quality of nursing care. Standardizing nursing procedures is key to improve the safety and quality of nursing care. Nursing and Health Policy are needed in Bosnia and Herzegovina to establish a functioning institutional framework, including regulatory bodies, educational systems for developing nurses' capacities or the

  17. Price adjustment for traditional Chinese medicine procedures: Based on a standardized value parity model.

    Science.gov (United States)

    Wang, Haiyin; Jin, Chunlin; Jiang, Qingwu

    2017-11-20

    Traditional Chinese medicine (TCM) is an important part of China's medical system. Due to the prolonged low price of TCM procedures and the lack of an effective mechanism for dynamic price adjustment, the development of TCM has markedly lagged behind Western medicine. The World Health Organization (WHO) has emphasized the need to enhance the development of alternative and traditional medicine when creating national health care systems. The establishment of scientific and appropriate mechanisms to adjust the price of medical procedures in TCM is crucial to promoting the development of TCM. This study has examined incorporating value indicators and data on basic manpower expended, time spent, technical difficulty, and the degree of risk in the latest standards for the price of medical procedures in China, and this study also offers a price adjustment model with the relative price ratio as a key index. This study examined 144 TCM procedures and found that prices of TCM procedures were mainly based on the value of medical care provided; on average, medical care provided accounted for 89% of the price. Current price levels were generally low and the current price accounted for 56% of the standardized value of a procedure, on average. Current price levels accounted for a markedly lower standardized value of acupuncture, moxibustion, special treatment with TCM, and comprehensive TCM procedures. This study selected a total of 79 procedures and adjusted them by priority. The relationship between the price of TCM procedures and the suggested price was significantly optimized (p based on a standardized value parity model is a scientific and suitable method of price adjustment that can serve as a reference for other provinces and municipalities in China and other countries and regions that mainly have fee-for-service (FFS) medical care.

  18. Improving the review of standard operating procedures: a novel electronic system for compounding pharmacies.

    Science.gov (United States)

    Brensel, Robert; Brensel, Scott; Ng, Amy

    2013-01-01

    Since the New England Compounding Center disaster in 2012, the importance of following correct procedures during every phase of customized pharmacy has been a focus of governmental interest and action as well as public scrutiny. Many pharmacies rely on the rote review of standard operating procedures to ensure that staff members understand and follow protocols that ensure the safety and potency of all compounds prepared, but that approach to continuing education can be cumbersome and needlessly time-consuming. In addition, documenting and retrieving evidence of employee competence can be difficult. In this article, we describe our use of online technology to improve our methods of educating staff about the full range of standard operating procedures that must be followed in our pharmacy. The system we devised and implemented has proven to be effective, easy to update and maintain, very inexpensive, and user friendly. Its use has reduced the time previously required for a read-over review of standard operating procedures from 30 or 40 minutes to 5 or 10 minutes in weekly staff meetings, and we can now easily document and access proof of employees' comprehension of that content. It is our hope that other small compounding pharmacies will also find this system of online standard operating procedure review helpful.

  19. The European Stroke Organisation Guidelines: a standard operating procedure.

    Science.gov (United States)

    Ntaios, George; Bornstein, Natan M; Caso, Valeria; Christensen, Hanne; De Keyser, Jacques; Diener, Hans-Christoph; Diez-Tejedor, Exuperio; Ferro, Jose M; Ford, Gary A; Grau, Armin; Keller, Emanuella; Leys, Didier; Russell, David; Toni, Danilo; Turc, Guillaume; Van der Worp, Bart; Wahlgren, Nils; Steiner, Thorsten

    2015-10-01

    In 2008, the recently founded European Stroke Organisation published its guidelines for the management of ischemic stroke and transient ischemic attack. This highly cited document was translated in several languages and was updated in 2009. Since then, the European Stroke Organisation has published guidelines for the management of intracranial aneurysms and subarachnoidal hemorrhage, for the establishment of stroke units and stroke centers, and recently for the management of intracerebral hemorrhage. In recent years, the methodology for the development of guidelines has evolved significantly. To keep pace with this progress and driven by the strong determination of the European Stroke Organisation to further promote stroke management, education, and research, the European Stroke Organisation decided to delineate a detailed standard operating procedure for its guidelines. There are two important cornerstones in this standard operating procedure: The first is the implementation of the Grading of Recommendations Assessment, Development, and Evaluation methodology for the development of its Guideline Documents. The second one is the decision of the European Stroke Organisation to move from the classical model of a single Guideline Document about a major topic (e.g. management of ischemic stroke) to focused modules (i.e. subdivisions of a major topic). This will enable the European Stroke Organisation to react faster when new developments in a specific stroke field occur and update its recommendations on the related module rather swiftly; with the previous approach of a single large Guideline Document, its entire revision had to be completed before an updated publication, delaying the production of up-to-date guidelines. After discussion within the European Stroke Organisation Guidelines Committee and significant input from European Stroke Organisation members as well as methodologists and analysts, this document presents the official standard operating procedure for

  20. 76 FR 54528 - Standard Operating Procedures (SOP) of the Aircraft Certification Service (AIR) Process for the...

    Science.gov (United States)

    2011-09-01

    ...) of the Aircraft Certification Service (AIR) Process for the Sequencing of Certification and... on the Aircraft Certification Service (AIR) standard operating procedure (SOP) describing the process... comments on the SOP : AIR-100-001; Standard Operating Procedure--Aircraft Certification Service Project...

  1. Impact of gastrectomy procedural complexity on surgical outcomes and hospital comparisons.

    Science.gov (United States)

    Mohanty, Sanjay; Paruch, Jennifer; Bilimoria, Karl Y; Cohen, Mark; Strong, Vivian E; Weber, Sharon M

    2015-08-01

    Most risk adjustment approaches adjust for patient comorbidities and the primary procedure. However, procedures done at the same time as the index case may increase operative risk and merit inclusion in adjustment models for fair hospital comparisons. Our objectives were to evaluate the impact of surgical complexity on postoperative outcomes and hospital comparisons in gastric cancer surgery. Patients who underwent gastric resection for cancer were identified from a large clinical dataset. Procedure complexity was characterized using secondary procedure CPT codes and work relative value units (RVUs). Regression models were developed to evaluate the association between complexity variables and outcomes. The impact of complexity adjustment on model performance and hospital comparisons was examined. Among 3,467 patients who underwent gastrectomy for adenocarcinoma, 2,171 operations were distal and 1,296 total. A secondary procedure was reported for 33% of distal gastrectomies and 59% of total gastrectomies. Six of 10 secondary procedures were associated with adverse outcomes. For example, patients who underwent a synchronous bowel resection had a higher risk of mortality (odds ratio [OR], 2.14; 95% CI, 1.07-4.29) and reoperation (OR, 2.09; 95% CI, 1.26-3.47). Model performance was slightly better for nearly all outcomes with complexity adjustment (mortality c-statistics: standard model, 0.853; secondary procedure model, 0.858; RVU model, 0.855). Hospital ranking did not change substantially after complexity adjustment. Surgical complexity variables are associated with adverse outcomes in gastrectomy, but complexity adjustment does not affect hospital rankings appreciably. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Standardized Procedure Content And Data Structure Based On Human Factors Requirements For Computer-Based Procedures

    International Nuclear Information System (INIS)

    Bly, Aaron; Oxstrand, Johanna; Le Blanc, Katya L

    2015-01-01

    Most activities that involve human interaction with systems in a nuclear power plant are guided by procedures. Traditionally, the use of procedures has been a paper-based process that supports safe operation of the nuclear power industry. However, the nuclear industry is constantly trying to find ways to decrease the human error rate, especially the human errors associated with procedure use. Advances in digital technology make computer-based procedures (CBPs) a valid option that provides further enhancement of safety by improving human performance related to procedure use. The transition from paper-based procedures (PBPs) to CBPs creates a need for a computer-based procedure system (CBPS). A CBPS needs to have the ability to perform logical operations in order to adjust to the inputs received from either users or real time data from plant status databases. Without the ability for logical operations the procedure is just an electronic copy of the paper-based procedure. In order to provide the CBPS with the information it needs to display the procedure steps to the user, special care is needed in the format used to deliver all data and instructions to create the steps. The procedure should be broken down into basic elements and formatted in a standard method for the CBPS. One way to build the underlying data architecture is to use an Extensible Markup Language (XML) schema, which utilizes basic elements to build each step in the smart procedure. The attributes of each step will determine the type of functionality that the system will generate for that step. The CBPS will provide the context for the step to deliver referential information, request a decision, or accept input from the user. The XML schema needs to provide all data necessary for the system to accurately perform each step without the need for the procedure writer to reprogram the CBPS. The research team at the Idaho National Laboratory has developed a prototype CBPS for field workers as well as the

  3. Standardized Procedure Content And Data Structure Based On Human Factors Requirements For Computer-Based Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Bly, Aaron; Oxstrand, Johanna; Le Blanc, Katya L

    2015-02-01

    Most activities that involve human interaction with systems in a nuclear power plant are guided by procedures. Traditionally, the use of procedures has been a paper-based process that supports safe operation of the nuclear power industry. However, the nuclear industry is constantly trying to find ways to decrease the human error rate, especially the human errors associated with procedure use. Advances in digital technology make computer-based procedures (CBPs) a valid option that provides further enhancement of safety by improving human performance related to procedure use. The transition from paper-based procedures (PBPs) to CBPs creates a need for a computer-based procedure system (CBPS). A CBPS needs to have the ability to perform logical operations in order to adjust to the inputs received from either users or real time data from plant status databases. Without the ability for logical operations the procedure is just an electronic copy of the paper-based procedure. In order to provide the CBPS with the information it needs to display the procedure steps to the user, special care is needed in the format used to deliver all data and instructions to create the steps. The procedure should be broken down into basic elements and formatted in a standard method for the CBPS. One way to build the underlying data architecture is to use an Extensible Markup Language (XML) schema, which utilizes basic elements to build each step in the smart procedure. The attributes of each step will determine the type of functionality that the system will generate for that step. The CBPS will provide the context for the step to deliver referential information, request a decision, or accept input from the user. The XML schema needs to provide all data necessary for the system to accurately perform each step without the need for the procedure writer to reprogram the CBPS. The research team at the Idaho National Laboratory has developed a prototype CBPS for field workers as well as the

  4. Factors related to postoperative pain among patients who underwent radiofrequency ablation of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Hsieh, Y.-C.; Yap, Y.-S.; Hung, C.-H.; Chen, C.-H.; Lu, S.-N.; Wang, J.-H.

    2013-01-01

    Aim: To evaluate the incidence and associated factors of postoperative intense pain and haemodynamic changes during radiofrequency ablation of hepatocellular carcinoma. Materials and methods: A total of 123 consecutive hepatocellular carcinoma patients who underwent radiofrequency ablation were prospectively recruited. Patient factors, tumour characteristics, procedural factors, intraoperative haemodynamic changes, complications, postoperative events, laboratory values before and after ablation, and postoperative pain were evaluated. Postoperative pain was scored using a visual analogue scale after the procedure. Results: The mean age of the patients was 65.6 ± 9.6 years. In multiple logistic regression analysis, patients who underwent general anaesthesia [odds ratio (95% CI): 2.68 (1.23–5.81); p = 0.013] and had more postoperative nausea and vomiting episodes [3.10 (1.11–8.63); p = 0.036] were associated with intense pain. These findings remain robust after propensity score matching. For mean difference values between before and after RFA, higher in change in aspartate transaminase (p = 0.026), alanine transaminase (p = 0.016) and white blood cell count (p = 0.015), and lower in change in haemoglobin (p = 0.009) were also correlated with intense pain. There was no significant difference in haemodynamic changes between the general anaesthesia and local anaesthesia group during ablation. Conclusion: General anaesthesia, postoperative nausea and vomiting, and laboratory factors were associated with postoperative intense pain in patients who underwent radiofrequency ablation. Counselling and modification of analgesics should be considered in patients with related factors for intense pain

  5. Environmental Sciences Division Toxicology Laboratory standard operating procedures

    International Nuclear Information System (INIS)

    Kszos, L.A.; Stewart, A.J.; Wicker, L.F.; Logsdon, G.M.

    1989-09-01

    This document was developed to provide the personnel working in the Environmental Sciences Division's Toxicology Laboratory with documented methods for conducting toxicity tests. The document consists of two parts. The first part includes the standard operating procedures (SOPs) that are used by the laboratory in conducting toxicity tests. The second part includes reference procedures from the US Environmental Protection Agency document entitled Short-Term Methods for Estimating the Chronic Toxicity of Effluents and Receiving Waters to Freshwater Organisms, upon which the Toxicology Laboratory's SOPs are based. Five of the SOPs include procedures for preparing Ceriodaphnia survival and reproduction test. These SOPs include procedures for preparing Ceriodaphnia food (SOP-3), maintaining Ceriodaphnia cultures (SOP-4), conducting the toxicity test (SOP-13), analyzing the test data (SOP-13), and conducting a Ceriodaphnia reference test (SOP-15). Five additional SOPs relate specifically to the fathead minnow (Pimephales promelas) larval survival and growth test: methods for preparing fathead minnow larvae food (SOP-5), maintaining fathead minnow cultures (SOP-6), conducting the toxicity test (SOP-9), analyzing the test data (SOP-12), and conducting a fathead minnow reference test (DOP-14). The six remaining SOPs describe methods that are used with either or both tests: preparation of control/dilution water (SOP-1), washing of glassware (SOP-2), collection and handling of samples (SOP-7), preparation of samples (SOP-8), performance of chemical analyses (SOP-11), and data logging and care of technical notebooks (SOP-16)

  6. The importance of production standard operating procedure in a family business company

    Science.gov (United States)

    Hongdiyanto, C.

    2017-12-01

    Plastic industry is a growing sector, therefore UD X which engage in this business has a great potential to grow as well. The problem faced by this family business company is that no standard operating procedure is used and it lead to problem in the quality and quantity produced. This research is aim to create a production standard operating procedure for UD X. Semistructure interview is used to gather information from respondent to help writer create the SOP. There are four SOP’s created, namely: classifying SOP, sorting SOP, milling SOP and packing SOP. Having SOP will improve the effectiveness of production because employees already know how to work in each stages of production process.

  7. FREY’S PROCEDURE- TO ANALYSE THE OUTCOME OF THIS PROCEDURE IN CHRONIC PANCREATITIS

    Directory of Open Access Journals (Sweden)

    Shilpa Mariappa Casaba

    2017-04-01

    Full Text Available BACKGROUND Chronic Pancreatitis (CP is a progressive inflammatory disease characterised by debilitating pain and pancreatic insufficiency. There is enormous personal and socio-economic impact on impairment of quality of life, inability to work and even shortening of life expectancy. Although, pancreaticoduodenectomy had been considered the standard surgical procedure for patients with CP because of its high post-op complications with exocrine and endocrine insufficiency, it is not preferred. This has led to a hybrid procedure described by Frey’s, which is used in our study for CP. We aim to analyse the short-term and long-term outcomes of Frey’s procedure at a tertiary care center in patients with chronic pancreatitis. MATERIALS AND METHODS A retrospective review of all CP patients who underwent Frey procedure were reviewed from January 2007-January 2016. Perioperative variables, short-term (30 days and long-term (3 years outcomes were reviewed. Data are frequency (% or mean. RESULTS A total of 97 patients underwent Frey’s procedure. A total of 72 (70.7% were men and 25 (29.3% were women. Mean age was 38 years (range 14-66 years. Indications for surgery included intractable pain (n=97, 100% and obstructive jaundice (n=4, 4.3%. 9 patients (32.6% were diabetic preoperatively. Concomitant procedures include biliary drainage procedure was done for 4 patients (4.3%, i.e. choledochojejunostomy and splenectomy for 2 patients (2.1%, cholecystectomy (n=6, 6%. Short-term outcomes include surgical site infection (n=10, 10%, pancreatic leak (n=6, 5.82% and 2 patients required reoperation for bleeding and no mortality (30 days, diabetic ketoacidosis (n=2, 2%. Pancreatic carcinoma was detected in 3 (2.1% patients. Long-term outcomes include pain free status (n=80, 86.9%, median follow-up of 3 years. Redo pancreatic procedure was performed in 1 (4.3% for anastomotic leak. CONCLUSION Frey’s procedure is a safe and effective pain palliative option for CP

  8. Manual for the GAW Precipitation Chemistry Programme: Guidelines, Data Quality Objectives and Standard Operating Procedures

    National Research Council Canada - National Science Library

    Allan, Mary A

    2004-01-01

    This is a manual for the Global Atmosphere Watch Precipitation Chemistry (GAW-PC) Programme. Where possible, it describes standard operating procedures and otherwise provides guidance on methods and procedures...

  9. A standardized procedure for using human corpus cavernosum strips to evaluate drug activity.

    Science.gov (United States)

    Mirone, V; Sorrentino, R; di Villa Bianca, R; Imbimbo, C; Palmieri, A; Fusco, F; Tajana, G; Cirino, G

    2000-01-01

    The main problem of using human corpus cavernosum (HCC) tissue to perform bioassay is linked to its limited availability further complicated by the heterogeneous source of the tissues used. Here, we show that gender reassignment is a reliable source of human tissue without major ethical problems. Indeed, the entire corpus cavernosum is obtained from the surgery procedure, which allows creating a standardized procedure to prepare HCC strip. In addition, human tissue, if kept in the fridge in the condition described, does not loose its ability to contract to phenylephrine (PE; alpha agonist), angiotensin II (AG II) and KCl up to 4 days. Furthermore, once contracted with PE, HCC relaxes to acetylcholine (endothelium-dependent mechanism); sodium nitroprusside (endothelium-independent mechanism); cromakalim (CRK), a K(ATP) channel opener; or alprostadil, a synthetic PGE2 (ALPR). In conclusion, we have standardized a procedure that allows the use of HCC strips to evaluate drug activity and/or to study pathophysiological mechanisms with an intact functional human tissue up to 4 days from the surgery procedure.

  10. “Heidelberg standard examination” and “Heidelberg standard procedures” – Development of faculty-wide standards for physical examination techniques and clinical procedures in undergraduate medical education

    Science.gov (United States)

    Nikendei, C.; Ganschow, P.; Groener, J. B.; Huwendiek, S.; Köchel, A.; Köhl-Hackert, N.; Pjontek, R.; Rodrian, J.; Scheibe, F.; Stadler, A.-K.; Steiner, T.; Stiepak, J.; Tabatabai, J.; Utz, A.; Kadmon, M.

    2016-01-01

    The competent physical examination of patients and the safe and professional implementation of clinical procedures constitute essential components of medical practice in nearly all areas of medicine. The central objective of the projects “Heidelberg standard examination” and “Heidelberg standard procedures”, which were initiated by students, was to establish uniform interdisciplinary standards for physical examination and clinical procedures, and to distribute them in coordination with all clinical disciplines at the Heidelberg University Hospital. The presented project report illuminates the background of the initiative and its methodological implementation. Moreover, it describes the multimedia documentation in the form of pocketbooks and a multimedia internet-based platform, as well as the integration into the curriculum. The project presentation aims to provide orientation and action guidelines to facilitate similar processes in other faculties. PMID:27579354

  11. Procedure and reference standard to determine the structural resolution in coordinate metrology

    Science.gov (United States)

    Illemann, Jens; Bartscher, Markus; Jusko, Otto; Härtig, Frank; Neuschaefer-Rube, Ulrich; Wendt, Klaus

    2014-06-01

    A new procedure and reference standards for specifying the structural resolution in coordinate metrology traceable to the SI unit the metre are proposed. With the definition of the structural resolution, a significant gap will be closed to complete ‘acceptance and verification tests’ of the coordinate measuring systems (CMSs) which are specified in the ISO 10360 series dealing with tactile sensors, optical sensors, and x-ray computed tomography measurement systems (CTs). The proposed new procedure uses reference standards with circular rounded edges. The idea is to measure the radius of curvature on a calibrated round edge structure. From the deviation between the measured and the calibrated radius, an analogue Gaussian broadening of the measurement system is determined. This value is a well-defined and easy-to-apply measure to define the structural resolution for dimensional measurements. It is applicable to CMSs which are based on different sensing principles, e.g. tactile, optical and CT systems. On the other hand, it has a physical meaning similar to the classical optical point-spread function. It makes it possible to predict which smallest details the CMS is capable of measuring reliably for an arbitrary object shape. The theoretical background of the new procedure is given, an appropriate reference standard is described and comparative, quantitative measurement data of CMSs featuring different sensors are shown.

  12. Standard operation procedures for conducting the on-the-road driving test, and measurement of the standard deviation of lateral position (SDLP).

    Science.gov (United States)

    Verster, Joris C; Roth, Thomas

    2011-01-01

    This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of 'weaving', is a stable measure of driving performance with high test-retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject's baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites.

  13. [Procedure of seed quality testing and seed grading standard of Prunus humilis].

    Science.gov (United States)

    Wen, Hao; Ren, Guang-Xi; Gao, Ya; Luo, Jun; Liu, Chun-Sheng; Li, Wei-Dong

    2014-11-01

    So far there exists no corresponding quality test procedures and grading standards for the seed of Prunus humilis, which is one of the important source of base of semen pruni. Therefor we set up test procedures that are adapt to characteristics of the P. humilis seed through the study of the test of sampling, seed purity, thousand-grain weight, seed moisture, seed viability and germination percentage. 50 cases of seed specimens of P. humilis tested. The related data were analyzed by cluster analysis. Through this research, the seed quality test procedure was developed, and the seed quality grading standard was formulated. The seed quality of each grade should meet the following requirements: for first grade seeds, germination percentage ≥ 68%, thousand-grain weight 383 g, purity ≥ 93%, seed moisture ≤ 5%; for second grade seeds, germination percentage ≥ 26%, thousand-grain weight ≥ 266 g, purity ≥ 73%, seed moisture ≤9%; for third grade seeds, germination percentage ≥ 10%, purity ≥ 50%, thousand-grain weight ≥ 08 g, seed moisture ≤ 13%.

  14. Standard working procedures in production of traditionally fermented Sremska sausage

    Directory of Open Access Journals (Sweden)

    Vesković-Moračanin Slavica

    2011-01-01

    Full Text Available Investigations conducted within project "Techonological and protective characteristics of autochthonous strains of lactic acid bacteria isolated from traditional fermented sausages and possibilities for their implementation in the meat industry" (Project Number: 20127, financed on behalf of the Ministry for Science and Technology of the Republic of Serbia, have provided an answer on the characteristics of the quality of the used raw materials for the production of Sremska sausage - one of the most well-known Serbian traditionally fermented sausages (choice of meat, fatty tissue, additives and spices, and data have been registered in connection with the procedures of their processing, microclimatic conditions have been established (temperature, relative humidity, and air circulation during the entire process of production and fermentation, as well as the presence and types of microorganisms, primarily lactic acid bacteria (BMK, the carrier of lactic fermentation. The most important characteristics of the filling have been established, the smoking regimen, the regimens of fermentation, maturing, drying, as well as the parameters for quality and safety of the finished product. At the same time, the standard working procedure has been determined for the preparation of the meat, fatty tissue, the forming and inserting of the filling into the wrappers, as well as the characteristics of the finished products. The given standard working procedure should serve as a guideline for the meat industry in the production process of this traditional fermented sausage.

  15. Current issues on a standard for surrogate pregnancy procedures

    OpenAIRE

    Ha, Jung-Ok

    2012-01-01

    While Korea does not have any legal statement on surrogacy, treatments are carried out in practice. As a result, every Institutional Review Board (IRB) of each fertility clinic faces an ethical predicament in reviewing each case. There is a need to arrange the institutions' own standards of surrogate pregnancy procedures before the establishment of national or professional regulation. This article examines the legal, social, and medical issues of surrogacy to help IRBs to judge their cases.

  16. Current issues on a standard for surrogate pregnancy procedures.

    Science.gov (United States)

    Ha, Jung-Ok

    2012-12-01

    While Korea does not have any legal statement on surrogacy, treatments are carried out in practice. As a result, every Institutional Review Board (IRB) of each fertility clinic faces an ethical predicament in reviewing each case. There is a need to arrange the institutions' own standards of surrogate pregnancy procedures before the establishment of national or professional regulation. This article examines the legal, social, and medical issues of surrogacy to help IRBs to judge their cases.

  17. The Payer and Patient Cost Burden of Open Breast Conserving Procedures Following Percutaneous Breast Biopsy.

    Science.gov (United States)

    Kimball, Chloe C; Nichols, Christine I; Vose, Joshua G

    2018-01-01

    Percutaneous core-needle biopsy (PCNB) is the standard of care to biopsy and diagnose suspicious breast lesions. Dependent on histology, many patients require additional open procedures for definitive diagnosis and excision. This study estimated the payer and patient out-of-pocket (OOP) costs, and complication risk, among those requiring at least 1 open procedure following PCNB. This retrospective study used the Truven Commercial database (2009-2014). Women who underwent PCNB, with continuous insurance, and no history of cancer, chemotherapy, radiation, or breast surgery in the prior year were included. Open procedures were defined as open biopsy or lumpectomy. Study follow-up ended at chemotherapy, radiation, mastectomy, or 90 days-whichever occurred first. In total, 143 771 patients (mean age 48) met selection criteria; 85.1% underwent isolated PCNB, 12.4% one open procedure, and 2.5% re-excision. Incidence of complications was significantly lower among those with PCNB alone (9.2%) vs 1 open procedure (15.6%) or re-excision (25.3%, P  open procedure vs PCNB alone (US $17 125 vs US $3935, P  open procedure vs PCNB alone (US $1527 vs US $669), and US $247 greater for re-excision vs 1 procedure. A meaningful proportion of patients underwent open procedure(s) following PCNB which was associated with increased complication risk and costs to both the payer and the patient. These results suggest a need for technologies to reduce the proportion of cases requiring open surgery and, in some cases, re-excision.

  18. Standard and procedures for measuring and evaluating of the field electromagnetic signals

    International Nuclear Information System (INIS)

    Fallas Cordero, Oscar

    2007-01-01

    Rules and procedures are developed for measuring the intensity of electromagnetic field signals produced by public commercial broadcasters. International and national standards applicable to existing broadcasting area were investigated. The Manual para la Comprobacion Tecnica de las Emisiones of the International Radio Consultative Committee of the International Telecommunications Union was used for reference in the procedures. It was worked in coordination with the Control Nacional de Radio and Radio U to obtain information and to study the teams to present a measurement system for laboratory that meets with the standards suggested and which can encompass a wide range of transmission services. Finally agreed with the analysis and research work done, a series of recommendations were made for improvement, which are considered to implement them in medium and long time. (author) [es

  19. Licensing procedure, nuclear codes and standards in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Schultheiss, G.F.

    1980-01-01

    The present paper deals with legal background of licensing in nuclear technology and atomic energy use, licensing procedures for nuclear power plants and with codes, standards and guidelines in the Federal Republic of Germany. (orig./RW)

  20. Estimating the Standard Error of the Judging in a modified-Angoff Standards Setting Procedure

    Directory of Open Access Journals (Sweden)

    Robert G. MacCann

    2004-03-01

    Full Text Available For a modified Angoff standards setting procedure, two methods of calculating the standard error of the..judging were compared. The Central Limit Theorem (CLT method is easy to calculate and uses readily..available data. It estimates the variance of mean cut scores as a function of the variance of cut scores within..a judging group, based on the independent judgements at Stage 1 of the process. Its theoretical drawback is..that it is unable to take account of the effects of collaboration among the judges at Stages 2 and 3. The..second method, an application of equipercentile (EQP equating, relies on the selection of very large stable..candidatures and the standardisation of the raw score distributions to remove effects associated with test..difficulty. The standard error estimates were then empirically obtained from the mean cut score variation..observed over a five year period. For practical purposes, the two methods gave reasonable agreement, with..the CLT method working well for the top band, the band that attracts most public attention. For some..bands in English and Mathematics, the CLT standard error was smaller than the EQP estimate, suggesting..the CLT method be used with caution as an approximate guide only.

  1. Chapter 8. Medical procedures. Recommendations and standard operating procedures for intensive care unit and hospital preparations for an influenza epidemic or mass disaster

    NARCIS (Netherlands)

    Zimmerman, Janice L.; Sprung, Charles L.; Christian, Michael D.; Camargo, Ruben; Ceraso, Daniel; Azoulay, Elie; Duguet, Alexandre; Guery, Benoit; Reinhart, Konrad; Adini, Bruria; Barlavie, Yaron; Benin-Goren, Odeda; Cohen, Robert; Klein, Motti; Leoniv, Yuval; Margalit, Gila; Rubinovitch, Bina; Sonnenblick, Moshe; Steinberg, Avraham; Weissman, Charles; Wolff, Donna; Kesecioglu, Jozef; de Jong, Menno; Moreno, Rui; An, Youzhong; Du, Bin; Joynt, Gavin M.; Colvin, John; Loo, Shi; Richards, Guy; Artigas, Antonio; Pugin, Jerome; Amundson, Dennis; Devereaux, Asha; Beigel, John; Danis, Marion; Farmer, Chris; Hick, John L.; Maki, Dennis; Masur, Henry; Rubinson, Lewis; Sandrock, Christian; Talmor, Daniel; Truog, Robert; Zimmerman, Janice; Brett, Steve; Montgomery, Hugh; Rhodes, Andrew; Sanderson, Frances; Taylor, Bruce

    2010-01-01

    To provide recommendations and standard operating procedures for intensive care unit and hospital preparations for an influenza pandemic or mass disaster with a specific focus on ensuring that adequate resources are available and appropriate protocols are developed to safely perform procedures in

  2. Incidence of postoperative implant-related bacterial endocarditis in dogs that underwent trans-catheter embolization of a patent ductus arteriosus without intra- and post-procedural prophylactic antibiotics.

    Science.gov (United States)

    Szatmári, Viktor

    2017-08-01

    Intra- and post-procedural prophylactic antibiotics are routinely administered by veterinary cardiologists to dogs that undergo trans-catheter embolization of a patent ductus arteriosus for prevention of implant-related infective endocarditis. The hypothesis of our study was that primary antibiotic prophylaxis is not necessary to prevent bacterial endocarditis. In this retrospective case series 54 client-owned dogs that underwent trans-catheter occlusion of a patent ductus arteriosus in a single tertiary veterinary referral center between 2004 and 2016 were evaluated. Follow-up information was gained by telephone interviews with the owners or the referring veterinarians, or from the digital archives of the authors' clinic. Inclusion criteria were that at least one metal implant (a coil or an Amplatz duct occluder) had to be delivered in the ductal ampulla, no local or systemic antibiotics were given on the day of the intervention or the week thereafter, at least 3 months of postoperative follow-up information was available, and the author was performing the procedure either as the primary or as the supervising cardiology specialist. None of the 54 dogs developed infective endocarditis in the postoperative 3 months. A study describing a similar population reports 2 of the included 47 dogs having developed infective endocarditis in the postoperative period despite the administration of intra- and post-procedural prophylactic antibiotics. We conclude that intra- and post-procedural antibiotic prophylaxis is not justified in dogs that undergo trans-catheter closure of a patent ductus arteriosus. Proper surgical technique and the use of new sterile catheters and implants are sufficient to prevent infective endocarditis in these dogs. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. How to develop a Standard Operating Procedure for sorting unfixed cells

    Science.gov (United States)

    Schmid, Ingrid

    2012-01-01

    Written Standard Operating Procedures (SOPs) are an important tool to assure that recurring tasks in a laboratory are performed in a consistent manner. When the procedure covered in the SOP involves a high-risk activity such as sorting unfixed cells using a jet-in-air sorter, safety elements are critical components of the document. The details on sort sample handling, sorter set-up, validation, operation, troubleshooting, and maintenance, personal protective equipment (PPE), and operator training, outlined in the SOP are to be based on careful risk assessment of the procedure. This review provides background information on the hazards associated with sorting of unfixed cells and the process used to arrive at the appropriate combination of facility design, instrument placement, safety equipment, and practices to be followed. PMID:22381383

  4. How to develop a standard operating procedure for sorting unfixed cells.

    Science.gov (United States)

    Schmid, Ingrid

    2012-07-01

    Written standard operating procedures (SOPs) are an important tool to assure that recurring tasks in a laboratory are performed in a consistent manner. When the procedure covered in the SOP involves a high-risk activity such as sorting unfixed cells using a jet-in-air sorter, safety elements are critical components of the document. The details on sort sample handling, sorter set-up, validation, operation, troubleshooting, and maintenance, personal protective equipment (PPE), and operator training, outlined in the SOP are to be based on careful risk assessment of the procedure. This review provides background information on the hazards associated with sorting of unfixed cells and the process used to arrive at the appropriate combination of facility design, instrument placement, safety equipment, and practices to be followed. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Modification of the Nuss Procedure: The Single-incision Technique

    Directory of Open Access Journals (Sweden)

    Tetsushi Aizawa, MD

    2014-11-01

    Full Text Available Summary: The Nuss procedure is a prevalent minimally invasive surgery for pectus excavatum. Although the Nuss procedure has the advantage of leaving less obtrusive scars, the standard technique requires at least 3 skin incisions to insert several instruments. We experienced 7 cases of the modified Nuss procedure using a single incision during a 7-year period. To facilitate passing of the bar, a traction guide was created according to our unique method. There was no need for a bar stabilizer, and no severe intraoperative complications occurred. All patients exhibited satisfactory short-term results; however, 1 patient suffered from bar rotation and required repeat surgery for fixation. Two patients underwent bar removal via the same single incision without any difficulties.

  6. Influence of new customs procedures and logistic security standards on companies competiveness – a Croatian company case study

    Directory of Open Access Journals (Sweden)

    Aleksandar Erceg

    2014-12-01

    Full Text Available In today’s global market, companies are constantly confronted with the competition on the local, national and international level. Companies therefore use a variety of strategies and tools to become and/or remain competitive. Potential areas for cost reduction in companies are supply chain management and logistic and customs procedures. Implementation of various logistic standards in supply chain management can provide significant cost savings for the company’s daily operations and thus reduce overall costs and improve the competitiveness. Using different customs procedures and logistic standards to reduce their costs and become more competitive in the market is necessary for Croatian companies. The method of using these tools is not a one-time process and requires constant efforts. Companies therefore have to be ready to improve daily to be and remain competitive. Using a variety of modern customs procedures can save their money and time, not only through these procedures, but also through better use of their employee’s time, their own vehicles and other equipment. The paper analyzes various customs procedures and logistic standards that can help companies save time and money and improve their competitiveness. In the example of Croatian company, which uses various available procedures and standards the benefits of their use are shown. Apart from bringing savings in operations, all these procedures and standards allow the company to be better, cheaper and more attractive to buyers.

  7. Standard audit procedure for continuous emission monitors and ambient air monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-06-15

    The instruments were published in an operational policy manual in 2009. This policy aims to introduce standard audit criteria that can be used to determine if continuous emission monitors and ambient air monitoring devices are operating within acceptable parameters. Before delivering upscale points of the instrument to be audited, each one of the audit equipment used in the field is required to be at normal operating conditions. Before the beginning of the audit, each one of the meteorological and flow measurement equipment is required to be conditioned to current conditions. If the audit fails, the instrument will have to be audited quarterly. The establishment of specific procedures based on instrument manufacturer or certifying body operational standards is required in the case of non-continuous monitoring instruments presenting operational principles outside of the audit procedures listed in the document.

  8. 15 CFR 10.7 - Procedure when a recommended standard is not supported by a consensus.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Procedure when a recommended standard is not supported by a consensus. 10.7 Section 10.7 Commerce and Foreign Trade Office of the Secretary... recommended standard is not supported by a consensus. If the Department determines that a recommended standard...

  9. Clinical outcomes for 14 consecutive patients with solid pseudopapillary neoplasms who underwent laparoscopic distal pancreatectomy.

    Science.gov (United States)

    Nakamura, Yoshiharu; Matsushita, Akira; Katsuno, Akira; Yamahatsu, Kazuya; Sumiyoshi, Hiroki; Mizuguchi, Yoshiaki; Uchida, Eiji

    2016-02-01

    The postoperative results of laparoscopic distal pancreatectomy for solid pseudopapillary neoplasm of the pancreas (SPN), including the effects of spleen-preserving resection, are still to be elucidated. Of the 139 patients who underwent laparoscopic pancreatectomy for non-cancerous tumors, 14 consecutive patients (average age, 29.6 years; 1 man, 13 women) with solitary SPN who underwent laparoscopic distal pancreatectomy between March 2004 and June 2015 were enrolled. The tumors had a mean diameter of 4.8 cm. Laparoscopic spleen-preserving distal pancreatectomy was performed in eight patients (spleen-preserving group), including two cases involving pancreatic tail preservation, and laparoscopic spleno-distal pancreatectomy was performed in six patients (standard resection group). The median operating time was 317 min, and the median blood loss was 50 mL. Postoperatively, grade B pancreatic fistulas appeared in two patients (14.3%) but resolved with conservative treatment. No patients had postoperative complications, other than pancreatic fistulas, or required reoperation. The median postoperative hospital stay was 11 days, and the postoperative mortality was zero.None of the patients had positive surgical margins or lymph nodes with metastasis. The median follow-up period did not significantly differ between the two groups (20 vs 39 months, P = 0.1368). All of the patients are alive and free from recurrent tumors without major late-phase complications. Laparoscopic distal pancreatectomy might be a suitable treatment for patients with SPN. A spleen-preserving operation is preferable for younger patients with SPN, and this study demonstrated the non-inferiority of the procedure compared to spleno-distal pancreatectomy. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  10. Measurement of patient radiation doses in certain urography procedures

    International Nuclear Information System (INIS)

    Sulieman, A.; Barakat, H.; Zailae, A.; Abuderman, A.; Theodorou, K.

    2015-01-01

    Patients are exposed to significant radiation doses during diagnostic and interventional urological procedures. This study aimed to measure patient entrance surface air kerma (ESAK) and to estimate the effective dose during intravenous urography (IVU), extracorporeal shock-wave lithotripsy (ESWL), and ascending urethrogram (ASU) procedures. ESAK was measured in patients using calibrated thermo luminance dosimeters, GR200A). Effective doses (E) were calculated using the National Radiological Protection Board (NRPB) software. A total of 179 procedures were investigated. 27.9 % of the patients underwent IVU procedures, 27.9 % underwent ESWL procedures and 44.2 % underwent ASU procedures. The mean ESAK was 2.1, 4.18 and 4.9 mGy for IVU, ESWL, and ASU procedures, respectively. Differences in patient ESAK for the same procedure were observed. The mean ESAK values were comparable with those in previous studies. (authors)

  11. The primary exposure standard for Co-60 gamma radiation: characteristics and measurements procedures

    International Nuclear Information System (INIS)

    Laitano, R.F.; Toni, M.P.

    1983-01-01

    A description is given of a cavity ionization chamber used, as a primary exposure standard, at the Laboratorio di Metrologia delle Radiazioni Ionizzanti of the ENEA in Italy. The primary standard is designed to make absolute measurements of exposure due to the Co-60 gamma radiation. The procedures for the realizationof the exposure unit are also described. Finally results of some international comparisons are reported

  12. Standard Guidelines of Care: Performing Procedures in Patients on or Recently Administered with Isotretinoin.

    Science.gov (United States)

    Mysore, Venkataram; Mahadevappa, Omprakash H; Barua, Shyamanta; Majid, Imran; Viswanath, Vishalakshi; Bhat, Ramesh M; Talwar, Suresh; Thurakkal, Salim; Aurangabadkar, Sanjeev J; Chatterjee, Manas; Ganjoo, Anil

    2017-01-01

    Currently, the standard protocol regarding the performance of procedures on patients receiving or having recently received isotretinoin (13- cis -retinoic acid) states that the procedures should not be performed. The recommendations in standard books and drug insert require discontinuation of isotretinoin for 6 months before performing cosmetic procedures, including waxing, dermabrasion, chemical peels, laser procedures, or incisional and excisional cold-steel surgery. These recommendations have been followed for over two decades despite little evidence for the stated increased risk of scarring. The Association of Cutaneous Surgeons (I) constituted a task force to review the evidence and to recommend consensus guidelines regarding the safety of skin procedures, including resurfacing, energy-device treatments, and dermatosurgical procedures in patients with concurrent or recent isotretinoin administration. Data were extracted from the literature through a PubMed search using the keywords "isotretinoin," "safety," "scarring," "keloids," "hypertrophic scarring," and "pigmentation." The evidence was then labeled and circulated to all members of task force for review. The task force is of the opinion that there is insufficient evidence to support the current protocol of avoiding and delaying treatments in the patient group under consideration and recommends that the current practice should be discontinued. The task force concludes that performing procedures such as laser hair removal, fractional lasers for aging and acne scarring, lasers for pigmented skin lesions, fractional radio-frequency microneedling, superficial and medium-depth peels, microdermabrasion, dermaroller, biopsies, radio-frequency ablation, and superficial excisions is safe in patients with concurrent or recent isotretinoin administration.

  13. 40 CFR 75.33 - Standard missing data procedures for SO2, NOX, Hg, and flow rate.

    Science.gov (United States)

    2010-07-01

    ... SO2, NOX, Hg, and flow rate. 75.33 Section 75.33 Protection of Environment ENVIRONMENTAL PROTECTION... Procedures § 75.33 Standard missing data procedures for SO2, NOX, Hg, and flow rate. (a) Following initial...—Missing Data Procedure for SO2 CEMS, CO2 CEMS, Moisture CEMS, Hg CEMS, and Diluent (CO2 or O2) Monitors...

  14. Standard testing procedures for optical fiber and unshielded twisted pair at Sandia National Laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Adams, R.L.

    1993-11-01

    This document will establish a working standard for testing optical fiber and unshielded twisted pair cables included in the Lab-wide telecommunications cabling system. The purpose of these standard testing procedures is to deliver to all Sandians a reliable, low-maintenance, state-of-the-art, ubiquitous telecommunications cabling infrastructure capable of satisfying all current and future telecommunication needs.

  15. 9 CFR 354.210 - Minimum standards for sanitation, facilities, and operating procedures in official plants.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Minimum standards for sanitation, facilities, and operating procedures in official plants. 354.210 Section 354.210 Animals and Animal Products... sanitation, facilities, and operating procedures in official plants. The provisions of §§ 354.210 to 354.247...

  16. Standard Operating Procedures for Female Genital Sexual Pain

    DEFF Research Database (Denmark)

    Fugl-Meyer, Kerstin S; Bohm-Starke, Nina; Damsted Petersen, Christina

    2012-01-01

    Introduction.  Female genital sexual pain (GSP) is a common, distressing complaint in women of all ages that is underrecognized and undertreated. Definitions and terminology for female GSP are currently being debated. While some authors have suggested that GSP is not per se a sexual dysfunction......, but rather a localized genial pain syndrome, others adhere to using clearly sexually related terms such as dyspareunia and vaginismus. Aim.  The aims of this brief review are to present definitions of the different types of female GSP. Their etiology, incidence, prevalence, and comorbidity with somatic......-Meyer KS, Bohm-Starke N, Damsted Petersen C, Fugl-Meyer A, Parish S, and Giraldi A. Standard operating procedures for female genital sexual pain. J Sex Med **;**:**-**....

  17. Standardization of specifications and inspection procedures for LEU plate-type research reactor fuels

    International Nuclear Information System (INIS)

    1988-06-01

    With the transition to high density uranium LEU fuel, fabrication costs of research reactor fuel elements have a tendency to increase because of two reasons. First, the amount of the powder of the uranium compound required increases by more than a factor of five. Second, fabrication requirements are in many cases nearer the fabrication limits. Therefore, it is important that measures be undertaken to eliminate or reduce unnecessary requirements in the specification or inspection procedures of research reactor fuel elements utilizing LEU. An additional stimulus for standardizing specifications and inspection procedures at this time is provided by the fact that most LEU conversions will occur within a short time span, and that nearly all of them will require preparation of new specifications and inspection procedures. In this sense, the LEU conversions offer an opportunity for improving the rationality and efficiency of the fuel fabrication and inspection processes. This report focuses on the standardization of specifications and inspection processes of high uranium density LEU fuels for research reactors. However, in many cases the results can also be extended directly to other research reactor fuels. 15 refs, 1 fig., 3 tabs

  18. Standard Guidelines of Care: Performing Procedures in Patients on or Recently Administered with Isotretinoin

    Science.gov (United States)

    Mysore, Venkataram; Mahadevappa, Omprakash H.; Barua, Shyamanta; Majid, Imran; Viswanath, Vishalakshi; Bhat, Ramesh M.; Talwar, Suresh; Thurakkal, Salim; Aurangabadkar, Sanjeev J.; Chatterjee, Manas; Ganjoo, Anil

    2017-01-01

    Background: Currently, the standard protocol regarding the performance of procedures on patients receiving or having recently received isotretinoin (13-cis-retinoic acid) states that the procedures should not be performed. The recommendations in standard books and drug insert require discontinuation of isotretinoin for 6 months before performing cosmetic procedures, including waxing, dermabrasion, chemical peels, laser procedures, or incisional and excisional cold-steel surgery. These recommendations have been followed for over two decades despite little evidence for the stated increased risk of scarring. Objective: The Association of Cutaneous Surgeons (I) constituted a task force to review the evidence and to recommend consensus guidelines regarding the safety of skin procedures, including resurfacing, energy-device treatments, and dermatosurgical procedures in patients with concurrent or recent isotretinoin administration. Materials and Methods: Data were extracted from the literature through a PubMed search using the keywords “isotretinoin,” “safety,” “scarring,” “keloids,” “hypertrophic scarring,” and “pigmentation.” The evidence was then labeled and circulated to all members of task force for review. Results: The task force is of the opinion that there is insufficient evidence to support the current protocol of avoiding and delaying treatments in the patient group under consideration and recommends that the current practice should be discontinued. The task force concludes that performing procedures such as laser hair removal, fractional lasers for aging and acne scarring, lasers for pigmented skin lesions, fractional radio-frequency microneedling, superficial and medium-depth peels, microdermabrasion, dermaroller, biopsies, radio-frequency ablation, and superficial excisions is safe in patients with concurrent or recent isotretinoin administration. PMID:29491653

  19. Standard guidelines of care: Performing procedures in patients on or recently administered with isotretinoin

    Directory of Open Access Journals (Sweden)

    Venkataram Mysore

    2017-01-01

    Full Text Available Background: Currently, the standard protocol regarding the performance of procedures on patients receiving or having recently received isotretinoin (13-cis-retinoic acid states that the procedures should not be performed. The recommendations in standard books and drug insert require discontinuation of isotretinoin for 6 months before performing cosmetic procedures, including waxing, dermabrasion, chemical peels, laser procedures, or incisional and excisional cold-steel surgery. These recommendations have been followed for over two decades despite little evidence for the stated increased risk of scarring. Objective: The Association of Cutaneous Surgeons (I constituted a task force to review the evidence and to recommend consensus guidelines regarding the safety of skin procedures, including resurfacing, energy-device treatments, and dermatosurgical procedures in patients with concurrent or recent isotretinoin administration. Materials and Methods: Data were extracted from the literature through a PubMed search using the keywords “isotretinoin,” “safety,” “scarring,” “keloids,” “hypertrophic scarring,” and “pigmentation.” The evidence was then labeled and circulated to all members of task force for review. Results: The task force is of the opinion that there is insufficient evidence to support the current protocol of avoiding and delaying treatments in the patient group under consideration and recommends that the current practice should be discontinued.The task force concludes that performing procedures such as laser hair removal, fractional lasers for aging and acne scarring, lasers for pigmented skin lesions, fractional radio-frequency microneedling, superficial and medium-depth peels, microdermabrasion, dermaroller, biopsies, radio-frequency ablation, and superficial excisions is safe in patients with concurrent or recent isotretinoin administration.

  20. Use of Low-Fidelity Simulation Laboratory Training for Teaching Radiology Residents CT-Guided Procedures.

    Science.gov (United States)

    Picard, Melissa; Nelson, Rachel; Roebel, John; Collins, Heather; Anderson, M Bret

    2016-11-01

    To determine the benefit of the addition of low-fidelity simulation-based training to the standard didactic-based training in teaching radiology residents common CT-guided procedures. This was a prospective study involving 24 radiology residents across all years in a university program. All residents underwent standard didactic lecture followed by low-fidelity simulation-based training on three common CT-guided procedures: random liver biopsy, lung nodule biopsy, and drain placement. Baseline knowledge, confidence, and performance assessments were obtained after the didactic session and before the simulation training session. Approximately 2 months later, all residents participated in a simulation-based training session covering all three of these procedures. Knowledge, confidence, and performance data were obtained afterward. These assessments covered topics related to preprocedure workup, intraprocedure steps, and postprocedure management. Knowledge data were collected based on a 15-question assessment. Confidence data were obtained based on a 5-point Likert-like scale. Performance data were obtained based on successful completion of predefined critical steps. There was significant improvement in knowledge (P = .005), confidence (P simulation-based training to the standard didactic curriculum for all procedures. This study suggests that the addition of low-fidelity simulation-based training to a standard didactic-based curriculum is beneficial in improving resident knowledge, confidence, and tested performance of common CT-guided procedures. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  1. Standard operating procedures improve acute neurologic care in a sub-Saharan African setting.

    Science.gov (United States)

    Jaiteh, Lamin E S; Helwig, Stefan A; Jagne, Abubacarr; Ragoschke-Schumm, Andreas; Sarr, Catherine; Walter, Silke; Lesmeister, Martin; Manitz, Matthias; Blaß, Sebastian; Weis, Sarah; Schlund, Verena; Bah, Neneh; Kauffmann, Jil; Fousse, Mathias; Kangankan, Sabina; Ramos Cabrera, Asmell; Kronfeld, Kai; Ruckes, Christian; Liu, Yang; Nyan, Ousman; Fassbender, Klaus

    2017-07-11

    Quality of neurologic emergency management in an under-resourced country may be improved by standard operating procedures (SOPs). Neurologic SOPs were implemented in a large urban (Banjul) and a small rural (Brikama) hospital in the Gambia. As quality indicators of neurologic emergency management, performance of key procedures was assessed at baseline and in the first and second implementation years. At Banjul, 100 patients of the first-year intervention group exhibited higher rates of general procedures of emergency management than 105 control patients, such as neurologic examination (99.0% vs 91.4%; p process quality of neurologic emergency management in under-resourced settings. This study provides Class IV evidence that, for patients with suspected neurologic emergencies in sub-Saharan Africa, neurologic SOPs increase the rate of performance of guideline-recommended procedures. Copyright © 2017 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Neurology.

  2. New Serbian criminal procedure: New reasons for harmonization with European legal standards

    Directory of Open Access Journals (Sweden)

    Đurđić Vojislav

    2014-01-01

    Full Text Available The new criminal procedure, set forth in 2011, represents a compilation of the inquisitive model of preliminary proceedings, on the one hand, and adversarial trial of the Anglo-American type of criminal procedure on the other. Introduction of the public prosecutor's investigation required a subtle legislative approach to the protection of human rights in criminal proceedings, in order to establish equilibrium between efficient and just procedure. Instead of the expected, the erroneous conception based on the ideas that the public prosecutor's investigation should be strictly formal as that of a court, that evidence taken by the non-judicial authorities should have the same bearing as those taken by the courts, and that the court should have no role in conducting investigation, resulted in an overly inferior position of the accuses compared to that of the public prosecutor. Beside the fact that such conception can not pass the ECJ test, the specific legal solutions referring the investigation open the question of harmonization with the European legal standards. The provisions on initiation of this phase of the proceedings, not being legally sanctioned, put in question the right of the accused to access justice, as well as his right to an effective legal remedy, and the introduced investigation against the unknown perpetrator, the right to be present at one's own trial is being jeopardized. Neither do all procedural rules pertaining to the trial support the fair procedure principle: the indirect extortion of evidence from the defense is discordant with the rule that the burden of proof lies on the prosecutor, as one of the main pillars of the assumption of innocence; as well as the broad opportunity to use non-judicial evidence at the hearing without any major legal obstacles, have demolished the principles of directness and contradictoriness. Even some of the minimal right of the defense as well as the guarantees of personal freedom in the course

  3. Comparison of Voice Quality Between Patients Who Underwent Inferior Turbinoplasty or Radiofrequency Cauterization.

    Science.gov (United States)

    Göker, Ayşe Enise; Aydoğdu, İmran; Saltürk, Ziya; Berkiten, Güler; Atar, Yavuz; Kumral, Tolgar Lütfi; Uyar, Yavuz

    2017-01-01

    The aim of this study was to analyze and compare the vocal quality in patients who underwent either submucosal turbinectomy or radiofrequency cauterization. In this study, we enrolled 60 patients diagnosed with inferior concha hypertrophy. These patients were divided into two groups by using computer program "Research Randomizer." Of the 60 patients, 30 underwent submucosal inferior turbinoplasty and 30 underwent radiofrequency cauterization. The control group was composed of 30 healthy adults with no nasal or upper aerodigestive system pathology. The patients were checked at weeks 1, 2, and 4. Voice records were taken before the procedure and at week 4 postprocedure. The mean age of patients in the inferior turbinoplasty group was 29.4 years (range: 19-42 years); in the radiofrequency group, it was 30.30 years (range: 18-50 years). There was no statistical difference in age between groups. In the inferior turbinoplasty group, there were 16 male and 14 female patients, and in the radiofrequency group, there were 13 male and 17 female patients. There was no significant difference in the number of males and females between groups. Voice professionals, especially singers, actors, and actresses, should be informed about possible voice changes before undergoing endonasal surgery because these individuals are more sensitive to changes in resonance organs. We believe that voice quality should be regarded as a highly important parameter when measuring the success of endonasal surgery. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  4. 75 FR 60171 - Proposed Information Collection (Credit Underwriting Standards and Procedures for Processing VA...

    Science.gov (United States)

    2010-09-29

    ... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0521] Proposed Information Collection (Credit Underwriting Standards and Procedures for Processing VA Guaranteed Loans) Activity: Comment Request AGENCY... comment on the proposed collection of certain information by the agency. Under the Paperwork Reduction Act...

  5. 78 FR 60379 - Proposed Information Collection (Credit Underwriting Standards and Procedures for Processing VA...

    Science.gov (United States)

    2013-10-01

    ... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0521] Proposed Information Collection (Credit Underwriting Standards and Procedures for Processing VA Guaranteed Loans) Activity: Comment Request AGENCY... comment on the proposed collection of certain information by the agency. Under the Paperwork Reduction Act...

  6. Evolution of standardized procedures for adjusting lumber properties for change in moisture content

    Science.gov (United States)

    David W. Green; James W. Evans

    2001-01-01

    This paper documents the development of procedures in American Society for Testing and Materials standards for adjusting the allowable properties of lumber for changes in moisture content. The paper discusses the historical context of efforts to establish allowable properties on a consensus basis, beginning in the 19th century. Where possible, the reasons for proposed...

  7. Comparative study of short-term cardiovascular autonomic control in cardiac surgery patients who underwent coronary artery bypass grafting or correction of valvular heart disease.

    Science.gov (United States)

    Shvartz, Vladimir A; Kiselev, Anton R; Karavaev, Anatoly S; Vulf, Kristina A; Borovkova, Ekaterina I; Prokhorov, Mikhail D; Petrosyan, Andrey D; Bockeria, Olga L

    2018-01-01

    Introduction: Our aim was to perform a comparative study of short-term cardiovascular autonomic control in cardiac surgery patients who underwent coronary artery bypass grafting (CABG) or surgical correction of valvular heart disease (SCVHD ). Methods: The synchronous 15 minutes records of heart rate variability (HRV) and finger's photoplethysmographic waveform variability (PPGV) were performed in 42 cardiac surgery patients (12 women) aged 61.8 ± 8.6 years (mean ± standard deviation), who underwent CABG, and 36 patients (16 women) aged 54.2 ± 14.9 years, who underwent SCVHD , before surgery and in 5-7 days after surgery. Conventional time and frequency domain measures of HRV and index S of synchronization between the slow oscillations in PPGV and HRV were analyzed. We also calculated personal dynamics of these indices after surgery. Results: We found no differences ( Р > 0.05) in all studied autonomic indices (preoperative and post-surgery) between studied patients' groups, except for the preoperative heart rate, which was higher in patients who underwent SCVHD ( P = 0.013). We have shown a pronounced preoperative and post-surgery variability (magnitude of inter-quartile ranges) of all autonomic indices in studied patients. In the cluster analysis based on cardiovascular autonomic indices (preoperative and post-surgery), we divided all patients into two clusters (38 and 40 subjects) which did not differ in all clinical characteristics (except for the preoperative hematocrit, P = 0.038), index S, and all post-surgery HRV indices. First cluster (38 patients) had higher preoperative values of the HR, TP, HF, and HF%, and lower preoperative values of the LF% and LF/HF. Conclusion: The variability of cardiovascular autonomic indices in on-pump cardiac surgery patients (two characteristic clusters were identified based on preoperative indices) was not associated with their clinical characteristics and features of surgical procedure (including cardioplegia).

  8. Standard Procedure for Grid Interaction Analysis

    International Nuclear Information System (INIS)

    Svensson, Bertil; Lindahl, Sture; Karlsson, Daniel; Joensson, Jonas; Heyman, Fredrik

    2015-01-01

    Grid events, simultaneously affecting all safety related auxiliary systems in a nuclear power plant, are critical and must be carefully addressed in the design, upgrading and operational processes. Up to now, the connecting grid has often been treated as either fully available or totally unavailable, and too little attention has been paid to specify the grid performance criteria. This paper deals with standard procedures for grid interaction analysis, to derive tools and criteria to handle grid events challenging the safety systems of the plant. Critical external power system events are investigated and characterised, with respect to severity and rate of occurrence. These critical events are then grouped with respect to impact on the safety systems, when a disturbance propagates into the plant. It is then important to make sure that 1) the impact of the disturbance will never reach any critical system, 2) the impact of the disturbance will be eliminated before it will hurt any critical system, or 3) the critical systems will be proven to be designed in such a way that they can withstand the impact of the disturbance, and the associated control and protection systems can withstand voltage and frequency transients associated with the disturbances. A number of representative disturbance profiles, reflecting connecting grid conditions, are therefore derived, to be used for equipment testing. (authors)

  9. 65. Impact of focused echocardiography in clinical decision of patients presented with STMI, underwent primary percutenouse angioplasty

    Directory of Open Access Journals (Sweden)

    M. Qasem

    2016-07-01

    Full Text Available Echocardiography in coronary artery diseases is an essential, routine echocardiography prior to primary percutaneous angioplasty is not clear. In our clinical practice in primary angioplasty we faced lots of complications either before or during or after the procedure. Moreover, lots of incidental findings that discovered after the procedure which if known will affect the plan of management. One-hundred-nineteen consecutive underwent primary angioplasty. All patients underwent FE prior to the procedure in catheterization lab while the patient was preparing for the procedure. FE with 2DE of LV at base, mid and apex, and apical stander views. Diastology grading, E/E′ and color doppler of mitral and aortic valve were performed. (N = 119 case of STMI were enrolled, mean age 51 ± 12 year. Eleven cases (9.2% had normal coronary and normal LV function. Twenty cases (17% of MI complication detected before the procedures: RV infarction 8.4% (5.1% asymptomatic and 3.3% symptomatic, ischemic MR (8.4%, LV apical aneurysm (0.8%, significant pericardial effusion (0.80%. Acute pulmonary edema in 17 cases (14.3%: six cases (5.1% developed acute pulmonary edema on the cath lab with grade 3 diastolic dysfunction and E/E ′  >20, 9 cases (7.6% develop acute pulmonary edema in CCU with grade 2–3 diastolic dysfunction and E/E′ 15–20. 2 cases (2.7% develop acute pulmonary in CCU with grade 1–2 diastolic dysfunction and E/E′ 9–14. One case (0.8% presented cardiac tamponade 2 h post PCI. Incidental finding not related to STMI were as follow: 2 cases (1.7% with severe fibro degenerative MR, 2 cases (1.7% with mild to moderate AR and 2 cases (1.7% with mild to moderate AS. Isoled CABG 5/4.2% and CABG and MVR 2/1.7%. FE play an important role in guiding the management, early detection the incidental findings and complication post PCI.

  10. 75 FR 76082 - Agency Information Collection (Credit Underwriting Standards and Procedures for Processing VA...

    Science.gov (United States)

    2010-12-07

    ... DEPARTMENT OF VETERANS AFFAIRS [OMB Control No. 2900-0521] Agency Information Collection (Credit Underwriting Standards and Procedures for Processing VA Guaranteed Loans) Activity Under OMB Review AGENCY... information abstracted below to the Office of Management and Budget (OMB) for review and comment. The PRA...

  11. Standard procedures for pooling health physics data for epidemiologic studies

    International Nuclear Information System (INIS)

    Strom, D.J.; Beck, W.L.; Stansbury, P.S.; Tankersley, W.G.; Watson, J.E. Jr.

    1983-01-01

    The objectives of the study are: (1) to determine the availability of dosimetry data and supporting documentation at multiple facilities; (2) to develop criteria and methods for optimally retrieving data; (3) to evaluate and document the quality and completeness of data and dosimetry programs; (4) to put dosimetry data (e.g., external, whole body counting, and bioassay data) from various facilities in a single format for epidemiologic analysis; and (5) to document all work for peer review. To achieve these objectives, a ''Dosimetry Records and Radiation Hazards Questionnaire'' was developed to send to the facilities under study. Responses to this questionnaire are used to develop data retrieval criteria and methods, and to retrieve data. Dose data are reformatted into Standard Intermediate Dosimetry Files for editing and characterization. Evaluations of dosimetry programs are performed concurrently. Results of these steps are brought together and analysis files created. Status of this work in the context of the Department of Energy 5-Rem Study is reported. The standard procedures are applicable to single- as well as multiple-facility studies

  12. Evaluation of the ISO standard 11063 DNA extraction procedure for assessing soil microbial abundance and community structure.

    Directory of Open Access Journals (Sweden)

    Pierre Plassart

    Full Text Available Soil DNA extraction has become a critical step in describing microbial biodiversity. Historically, ascertaining overarching microbial ecological theories has been hindered as independent studies have used numerous custom and commercial DNA extraction procedures. For that reason, a standardized soil DNA extraction method (ISO-11063 was previously published. However, although this ISO method is suited for molecular tools such as quantitative PCR and community fingerprinting techniques, it has only been optimized for examining soil bacteria. Therefore, the aim of this study was to assess an appropriate soil DNA extraction procedure for examining bacterial, archaeal and fungal diversity in soils of contrasting land-use and physico-chemical properties. Three different procedures were tested: the ISO-11063 standard; a custom procedure (GnS-GII; and a modified ISO procedure (ISOm which includes a different mechanical lysis step (a FastPrep ®-24 lysis step instead of the recommended bead-beating. The efficacy of each method was first assessed by estimating microbial biomass through total DNA quantification. Then, the abundances and community structure of bacteria, archaea and fungi were determined using real-time PCR and terminal restriction fragment length polymorphism approaches. Results showed that DNA yield was improved with the GnS-GII and ISOm procedures, and fungal community patterns were found to be strongly dependent on the extraction method. The main methodological factor responsible for differences between extraction procedure efficiencies was found to be the soil homogenization step. For integrative studies which aim to examine bacteria, archaea and fungi simultaneously, the ISOm procedure results in higher DNA recovery and better represents microbial communities.

  13. U.S. Geological Survey Noble Gas Laboratory’s standard operating procedures for the measurement of dissolved gas in water samples

    Science.gov (United States)

    Hunt, Andrew G.

    2015-08-12

    This report addresses the standard operating procedures used by the U.S. Geological Survey’s Noble Gas Laboratory in Denver, Colorado, U.S.A., for the measurement of dissolved gases (methane, nitrogen, oxygen, and carbon dioxide) and noble gas isotopes (helium-3, helium-4, neon-20, neon-21, neon-22, argon-36, argon-38, argon-40, kryton-84, krypton-86, xenon-103, and xenon-132) dissolved in water. A synopsis of the instrumentation used, procedures followed, calibration practices, standards used, and a quality assurance and quality control program is presented. The report outlines the day-to-day operation of the Residual Gas Analyzer Model 200, Mass Analyzer Products Model 215–50, and ultralow vacuum extraction line along with the sample handling procedures, noble gas extraction and purification, instrument measurement procedures, instrumental data acquisition, and calculations for the conversion of raw data from the mass spectrometer into noble gas concentrations per unit mass of water analyzed. Techniques for the preparation of artificial dissolved gas standards are detailed and coupled to a quality assurance and quality control program to present the accuracy of the procedures used in the laboratory.

  14. Teachers' use of a self-assessment procedure : the role of criteria, standards, feedback and reflection

    NARCIS (Netherlands)

    Diggelen, van M.R.; Brok, den P.J.; Beijaard, D.

    2013-01-01

    This article reports on the way teachers assess their own coaching competencies regarding the development of vocational education students’ reflection skills. The participating teachers used a self-assessment procedure in which they had to judge themselves with the help of criteria and standards,

  15. The standardized surgical approach improves outcome of gallbladder cancer

    Directory of Open Access Journals (Sweden)

    Igna Dorian

    2007-05-01

    Full Text Available Abstract Background The objective of this study was to examine the extent of surgical procedures, pathological findings, complications and outcome of patients treated in the last 12 years for gallbladder cancer. Methods The impact of a standardized more aggressive approach compared with historical controls of our center with an individual approach was examined. Of 53 patients, 21 underwent resection for cure and 32 for palliation. Results Overall hospital mortality was 9% and procedure related mortality was 4%. The standardized approach in UICC stage IIa, IIb and III led to a significantly improved outcome compared to patients with an individual approach (Median survival: 14 vs. 7 months, mean+/-SEM: 26+/-7 vs. 17+/-5 months, p = 0.014. The main differences between the standardized and the individual approach were anatomical vs. atypical liver resection, performance of systematic lymph dissection of the hepaticoduodenal ligament and the resection of the common bile duct. Conclusion Anatomical liver resection, proof for bile duct infiltration and, in case of tumor invasion, radical resection and lymph dissection of the hepaticoduodenal ligament are essential to improve outcome of locally advanced gallbladder cancer.

  16. Standard operating procedures for female orgasmic disorder: consensus of the International Society for Sexual Medicine

    NARCIS (Netherlands)

    Laan, Ellen; Rellini, Alessandra H.; Barnes, Tricia

    2013-01-01

    As the field of sexual medicine evolves, it is important to continually improve patient care by developing contemporary "standard operating procedures" (SOPs), reflecting the consensus view of experts in sexual medicine. Few, if any, consensus SOPs have been developed for the diagnosis and treatment

  17. Standard-E hydrogen monitoring system shop acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T.C.

    1997-10-02

    The purpose of this report is to document that the Standard-E Hydrogen Monitoring Systems (SHMS-E), fabricated by Mid-Columbia Engineering (MCE) for installation on the Waste Tank Farms in the Hanford 200 Areas, are constructed as intended by the design. The ATP performance will verify proper system fabrication.

  18. [Knapp procedure and modified Knapp procedure with Foster suture for the treatment of double elevator palsy].

    Science.gov (United States)

    Li, Y P; Zhang, W; Ding, J; Ma, H Z; Zhao, K X

    2017-12-11

    Objective: To investigate the efficacy of Knapp procedure and modified Knapp procedure with Foster suture in the treatment of double elevator palsy(DEP). Methods: Retrospective study. Twenty-two patients with congenital DEP were underwent Knapp procedure ( n= 15) and modified Knapp procedure( n= 7). The clinical data were retrospectively analyzed, including the preoperative and postoperative vertical deviation in the primary position, ocular motility, and binocular vision. Results: The average vertical deviation in the primary position was (34.7±8.6) prism diopters(PD) before surgery and (6.5±6.5) PD after surgery ( t= 30.41, P= 0.00) in the group underwent Knapp procedure. The mean preoperative and postoperative deviations of the group underwent modified procedure were respectively (38.6±14.6) PD and (5.7±9.3)PD ( t= 15.33, P= 0.00). The mean corrected vertical deviation of the latter (32.8±5.7) PD was greater than that of the former (28.1±3.6) PD( t=- 2.39, P= 0.03). The mean improved upgaze in the modified group (2.6±0.5) was more obvious than that in the Knapp group (1.9±0.6) ( t= 2.41, P= 0.02). There is no significant difference in the surgical effect on downgaze between two groups ( U =43.00, P= 0.54). Seven patients having binocular vision with abnormal head posture (AHP) before surgery obtained binocular single vision in the primary position and reading position after operations. AHP disappeared or reduced to less than 5°. The surgical outcomes were satisfied in 72.7% patients. But the patients with ≥40 PD preoperative vertical deviation were under-corrected and needed the further operations. Conclusions: Knapp procedure and modified Knapp procedure with Foster suture were the efficient procedures for treatment of DEP without restriction of ipsilateral inferior rectus. Both procedures can obviously correct the vertical deviation and improve upgaze without remarkable limitation of downgaze, which is good to obtain the binocular single vision in

  19. Assessment of organ doses by standard X-ray procedures in the GDR

    International Nuclear Information System (INIS)

    Tautz, M.; Brandt, G.A.

    1986-01-01

    A modern method has been described to assess the radiation burden by X-ray procedures with consideration of the standards of our Society for Medical Radiology in the GDR. The underlying methodology is a Monte Carlo computer technique, which simulates stochastically the energy deposition of X-ray photons in a mathematically described heterogeneous anthropomorphic phantom by Rosenstein (US Department of Health, Education and Welfare). To apply the procedure specific values for the following parameters must be determined for each dose estimation: projection and view, X-ray field size and location entrance exposure at skin surface, beam quality, source-to-image receptor distance. The base data are obtained in terms of tissue-air ratio. Organ doses were calculated for chest, urography, skull, cervical spine, thoracic spine, lumbar spine, pelvis and lymphography. Concluding possibilities have been discussed for reduction of radiation burden. 9 refs., 6 figs., 9 tabs. (author)

  20. Standardized uptake values of fluorine-18 fluorodeoxyglucose: the value of different normalization procedures

    International Nuclear Information System (INIS)

    Schomburg, A.; Bender, H.; Reichel, C.; Sommer, T.; Ruhlmann, J.; Kozak, B.; Biersack, H.J.

    1996-01-01

    While the evident advantages of absolute metabolic rate determinations cannot be equalled by static image analysis of fluorine-18 fluorodexyglucose positron emission tomographic (FDG PET) studies, various algorithms for the normalization of static FDG uptake values have been proposed. This study was performed to compare different normalization procedures in terms of dependency on individual patient characteristics. Standardized FDG uptake values (SUVs) were calculated for liver and lung tissue in 126 patients studied with whole-body FDG PET. Uptake values were normalized for total body weight, lean body mass and body surface area. Ranges, means, medians, standard deviations and variation coefficients of these SUV parameters were calculated and their interdependency with total body weight, lean body mass, body surface area, patient height and blood sugar levels was calculated by means of regression analysis. Standardized FDG uptake values normalized for body surface area were clearly superior to SUV parameters normalized for total body weight or lean body mass. Variation and correlation coefficients of body surface area-normalized uptake values were minimal when compared with SUV parameters derived from the other normalization procedures. Normalization for total body weight resulted in uptake values still dependent on body weight and blood sugar levels, while normalization for lean body mass did not eliminate the positive correlation with lean body mass and patient height. It is concluded that normalization of FDG uptake values for body surface area is less dependent on the individual patient characteristics than are FDG uptake values normalized for other parameters, and therefore appears to be preferable for FDG PET studies in oncology. (orig.)

  1. Primary calibration of TXRF in comparison with the standard droplet procedure

    International Nuclear Information System (INIS)

    Dobler, M.; Reus, U.; Knoth, J.; Schwenke, H.

    2000-01-01

    For the determination of contamination on wafer surfaces with total reflection x-ray fluorescence spectrometry (TXRF) normally external 1 ng Ni droplet standards were used for calibration. This method is based on several assumptions about the properties of the standard droplet which are strongly affected by the preparation of the samples. In this paper a study is resented which compares the external droplet method with a calibration procedure using the fundamental physical background of total reflection x-ray fluorescence spectrometry and the properties of Ni bulk material. The particular features of the two methods will be discussed and the obtained results compared to each other. It is demonstrated in this study that the calibration with Ni bulk material is a primary method which offers several advantages compared to the calibration based on droplet standards. These advantages are unique and enable a more reliable and reproducible quantification of contamination on wafer surfaces. This is caused by the fact that the method is standardless and only based on fundamental parameters and natural constants. It is also demonstrated that effects which could be caused by especial features of the measured samples (particle or film, e.g.) or by the degradation of the calibration sample could be excluded. (author)

  2. Comparative analysis of pain in patients who underwent total knee replacement regarding the tourniquet pressure

    Directory of Open Access Journals (Sweden)

    Marcos George de Souza Leão

    Full Text Available ABSTRACT OBJECTIVES: To evaluate through the visual analog scale (VAS the pain in patients undergoing total knee replacement (TKR with different pressures of the pneumatic tourniquet. METHODS: An observational, randomized, descriptive study on an analytical basis, with 60 patients who underwent TKR, divided into two groups, which were matched: a group where TKR was performed with tourniquet pressures of 350 mmHg (standard and the other with systolic blood pressure plus 100 mmHg (P + 100. These patients had their pain assessed by VAS at 48 h, and at the 5th and 15th days after procedure. Secondarily, the following were also measured: range of motion (ROM, complications, and blood drainage volume in each group; the data were subjected to statistical analysis. RESULTS: After data analysis, there was no statistical difference regarding the incidence of complications (p = 0.612, ROM (p = 0.202, bleeding after 24 and 48 h (p = 0.432 and p = 0.254 or in relation to VAS. No correlation was observed between time of ischemia compared to VAS and bleeding. CONCLUSIONS: The use of the pneumatic tourniquet pressure at 350 mmHg or systolic blood pressure plus 100 mmHg did not influence the pain, blood loss, ROM, and complications. Therefore the pressures at these levels are safe and do not change the surgery outcomes; the time of ischemia must be closely observed to avoid major complications.

  3. 21 CFR 606.100 - Standard operating procedures.

    Science.gov (United States)

    2010-04-01

    ... units. (9) Procedures for investigating adverse donor and recipient reactions. (10) Storage temperatures... accurately relating the product(s) to the donor. (5) Blood collection procedure, including in-process precautions taken to measure accurately the quantity of blood removed from the donor. (6) Methods of component...

  4. CSNI international standard problem procedures - CSNI Report No. 17 - Revision 4

    International Nuclear Information System (INIS)

    Micaelli, J.C.

    2004-01-01

    . Careful consideration and planning is therefore required. After a brief recall of the ISPs' objectives, this document provides guidelines to be followed during the different phases of an ISP. Two phases are considered. The first one consists in proposing and selecting an ISP, the second one consists in performing an ISP. This revised document was prepared under the Leadership of J.-C. Micaelli (IRSN). It was reviewed and endorsed in September 2003 by the Working Group on the Analysis and Management of Accidents (GAMA), GAMA performed in 2003 a survey on updating CSNI Report No. 17, 'CSNI Standard Problem Procedures', first published in 1977, last updated in 1989. The objective of this activity was to collect proposals regarding the improvement of ISP efficiency with respect to their objectives and the improvement of the quality of the procedures document. Eleven series of questions were asked in the survey, related to: - General structure of the procedures document; - ISP objectives; - Six phases: ISP proposal, ISP specification, ISP results reporting, Preparation of the preliminary data comparison and interpretation report, Post-ISP analysis, Preparation of the final comparison and interpretation report; - Updating of the procedures; - Support to be provided by the participants

  5. Teachers' Use of a Self-Assessment Procedure: The Role of Criteria, Standards, Feedback and Reflection

    Science.gov (United States)

    van Diggelen, Migchiel; den Brok, Perry; Beijaard, Douwe

    2013-01-01

    This article reports on the way teachers assess their own coaching competencies regarding the development of vocational education students' reflection skills. The participating teachers used a self-assessment procedure in which they had to judge themselves with the help of criteria and standards, received feedback from a colleague based on the…

  6. Radioisotopic studies concerning the efficacy of standard washing procedures for the cleansing of hair before zinc analysis

    International Nuclear Information System (INIS)

    Buckley, R.A.; Dreosti, I.E.

    1984-01-01

    Various standard procedures were investigated in relation to the removal of exogenously applied 65Zn from human hair and endogenously incorporated 65Zn from rat hair. Human hair was found to adsorb zinc and a variety of other metal ions from aqueous solutions in a manner which suggested some ion-exchange capacity. Uptake of zinc varied considerably between human hair samples, but in most cases accumulation of zinc occurred rapidly and often resulted in hair zinc levels several-fold higher than found in control samples. Extraction of zinc and other metal ions was greatest after treatment with disodium EDTA and sodium lauryl sulfate than after washing with water or aqueous Triton X-100. However, no procedure effectively removed all exogenous zinc, while all treatments extracted varying proportions of the endogenous zinc component. Because of the inability of standard washing procedures to remove exogenous zinc without reducing endogenous or indicator zinc levels, use of hair zinc analyses to indicate nutritional zinc status are inadvisable if hair zinc contamination is likely to have occurred

  7. Quality assurance: Importance of systems and standard operating procedures.

    Science.gov (United States)

    Manghani, Kishu

    2011-01-01

    It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.

  8. Quality assurance: Importance of systems and standard operating procedures

    Directory of Open Access Journals (Sweden)

    Kishu Manghani

    2011-01-01

    Full Text Available It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.

  9. Surrogate pregnancy in a patient who underwent radical hysterectomy and bilateral transposition of ovaries.

    Science.gov (United States)

    Azem, Foad; Yovel, Israel; Wagman, Israel; Kapostiansky, Rita; Lessing, Joseph B; Amit, Ami

    2003-05-01

    To evaluate IVF-surrogate pregnancy in a patient with ovarian transposition after radical hysterectomy for carcinoma of the cervix. Case report. A maternity hospital in Tel Aviv that is a major tertiary care and referral center. A 29-year-old woman who underwent Wertheim's hysterectomy for carcinoma of the uterine cervix and ovarian transposition before total pelvic irradiation. Standard IVF treatment, transabdominal oocyte retrieval, and transfer to surrogate mother. Outcome of IVF cycle. A twin pregnancy in the first cycle. This is the second reported case of controlled ovarian stimulation and oocyte retrieval performed on a transposed ovary.

  10. Long-term results of Heller myotomy without an antireflux procedure in achalasic patients.

    Science.gov (United States)

    Cortesini, Camillo; Cianchi, Fabio; Pucciani, Filippo

    2002-01-01

    Both open and laparoscopic myotomies have been used in the treatment of achalasia. Postoperative gastro-oesophageal reflux is among the commonly reported side effects of myotomy. The addition of an antireflux procedure to the standard surgical approach has given rise to controversy. The objective of our study was to determine whether or not an antireflux procedure should be used in addition to Heller myotomy. Over the period from 1980 to 1990, 94 patients (mean age: 47.9 years) with achalasia underwent Heller myotomy calibrated by intraoperative oesophageal manometry without fundoplication. In 1999-2000, all patients filled in a clinical questionnaire: all underwent radiographic oesophageal imaging, oesophageal manometry, ambulatory 24-h oesophageal pH monitoring, and oesophagogastroduodenoscopy, when necessary. Ten healthy age-matched subjects were compared in the manometric and radiological studies. Myotomy improved the clinical profiles and instrumental data results in all patients. Gastro-oesophageal reflux was present in 10 patients (10.6%); none of these 10 subjects presented oesophagitis. Heller open myotomy yields good long-term results. Intraoperative manometric calibration reduces the side effects of myotomy, such as gastro-oesophageal reflux. The addition of fundoplication is not justified in all patients.

  11. Preoperative Decision Making for Nephron-Sparing Procedure in the Renal Mass: Time for Using Standard Tools?

    NARCIS (Netherlands)

    Zondervan, Patricia J.; van Lienden, Krijn P.; van Delden, Otto M.; de La Rosette, Jean J. M. C. H.; Laguna, M. Pilar

    2016-01-01

    To determine if the application of using standard tools on tumor complexity and comorbidity indexes may replace the traditional choice of nephron-sparing procedure (NSP) based on clinical maximal tumor diameter (cMTD), age, and comorbidity. Anatomic complexity scores (PADUA and RENAL) and Charlson

  12. Audit of radiation dose during balloon mitral valvuloplasty procedure

    International Nuclear Information System (INIS)

    Livingstone, Roshan S; Chandy, Sunil; Peace, B S Timothy; George, Paul; John, Bobby; Pati, Purendra

    2006-01-01

    Radiation doses to patients during cardiological procedures are of concern in the present day scenario. This study was intended to audit the radiation dose imparted to patients during the balloon mitral valvuloplasty (BMV) procedure. Thirty seven patients who underwent the BMV procedure performed using two dedicated cardiovascular machines were included in the study. The radiation doses imparted to patients were measured using a dose area product (DAP) meter. The mean DAP value for patients who underwent the BMV procedure from one machine was 19.16 Gy cm 2 and from the other was 21.19 Gy cm 2 . Optimisation of exposure parameters and radiation doses was possible for one machine with the use of appropriate copper filters and optimised exposure parameters, and the mean DAP value after optimisation was 9.36 Gy cm 2

  13. [Results of an experience with the Bentall procedure].

    Science.gov (United States)

    Gallego, Javier; Ferreira, R; Roque, J; Guerra, N; Gennari, M; Serpa, C; Mendes, S; Mendes, M; Lucero, R; Lemos, A; Pereira, R; Nobre, A; Cravino, J

    2008-01-01

    The authors report a retrospective study of patients who underwent a Bentall procedure in the Cardio-Thoracic Surgery Department of Hospital Santa Maria, Lisbon. Data were obtained from 42 patients who underwent the Bentall procedure between 1991 and 2008. Different parameters were compared as well as the short and long term results. The median age was 58,5 years being 88% of patients of male gender. 32 (76,27%) presented with ascending aorta degenerative aneurism, 6 p (14,3%) with type A aortic dissection and 4p (9,5%) with Marfan syndrome. 10p(23.8%) had associated coronary artery disease and there were 6p (14.3%) who underwent emergency surgery. Among the risk factors associated, 24 p (57,1%) had hypertension, 12 p (28,6%) dyslipidemia, 4p (9,5%) had history of smoking, 7 p (16,7%) diabetes, 6 p (14,3%) CPOD, 2 p (4,8%) renal dysfunction and 2 had a recent myocardial infarction. There were 7p (16,7%) with left ventricular dysfunction (EFBentall procedure obtained good results in short and long term and, despite the emerging of new and more complex techniques like remodelling and reimplantation, our results support the maintenance of this procedure as the preferential treatment for aortic root and valvular disease.

  14. A review on test procedure, energy efficiency standards and energy labels for room air conditioners and refrigerator-freezers

    Energy Technology Data Exchange (ETDEWEB)

    Mahlia, T.M.I.; Saidur, R. [Department of Mechanical Engineering, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2010-09-15

    Air conditioners and refrigerator-freezers are major energy users in a household environment and hence efficiency improvement of these appliances can be considered as an important step to reduce their energy consumption along with environmental pollution prevention. Energy efficiency standards and labels are commonly used tools to reduce the energy uses for household appliances for many countries around the world. The first step towards adopting energy efficiency standards is to establish a test procedure for rating and testing of an appliance. It may be mentioned that an energy test procedure is the technical foundation for energy efficiency standards, energy labels, and other related programs. This paper reviews requirements and specifications of various international test standards for testing and rating of room air conditioners and refrigerators. A review on the development of the energy efficiency standards has been provided as well. Finally, energy labels that provide some useful information for identifying energy efficient products have been reviewed for these appliances. It may be stated that the review will be useful for the developing countries who wish to develop these energy savings strategies. It is also expected to be useful to revise the existing strategies for a few selected countries who already implemented these strategies earlier. (author)

  15. Performance testing of HEPA filters: Progress towards a European standard procedure

    Energy Technology Data Exchange (ETDEWEB)

    Dyment, J.

    1997-08-01

    Proposals for a future European testing procedure for {open_quotes}High Efficiency Particulate Air Filters (HEPA and ULPA){close_quotes} are being developed by CEN (Comite Europeen de Normalisation). The new standard will be given the status of national standard in participating countries, conflicting national standards being withdrawn. The standard will comprise 5 parts covering the grouping and classification of HEPA and ULPA filters according to their efficiency, fundamental principles of testing, marking etc (in part 1). Part 2 will cover aerosol production, measurement principles, counting equipment and statistics. Parts 3-5 will cover testing flat sheet media, leak testing of filter elements and the efficiency testing of filter elements respectively. The efficiency test methods allow the use of either homogeneous monodisperse or polydisperse aerosols for the determination of particulate filtration efficiencies as a function of particle size. The particle size at which maximum penetration occurs is first determined in flat sheet media tests; tests on filter elements (constructed using the same filter medium) may be carried out using either a homogeneous monodisperse aerosol of the size at which maximum penetration occurs (MPPS) or a polydisperse aerosol whose median size is close to the MPPS. Tests with monodisperse aerosols may be conducted using condensation nucleus counting equipment; tests using polydisperse test aerosols require the use of optical sizing particle counters. When determining the efficiency of filter elements the downstream aerosol concentrations may be determined from air samples obtained using either an overall method (single point sampling after mixing) or a scan method. The scan method also allows {open_quotes}local{close_quotes} efficiency values to be determined. 1 ref., 1 fig., 1 tab.

  16. Standard formatted data units-control authority procedures

    Science.gov (United States)

    1991-01-01

    The purpose of this document is to establish a set of minimum and optional requirements for the implementation of Control Authority (CA) organizations within and among the Agencies participating in the Consultative Committee for Space Data Systems (CCSDS). By satisfying these requirements, the resultant cooperating set of CA organizations will produce a global CA service supporting information transfer with digital data under the Standard Formatted Data Unit (SFDU) concept. This service is primarily accomplished through the registration, permanent archiving, and dissemination of metadata in the form of Metadata Objects (MDO) that assist in the interpretation of data objects received in SFDU form. This Recommendation addresses the responsibilities, services, and interface protocols for a hierarchy of CA organizations. The top level, consisting of the CCSDS Secretariat and its operational agent, is unique and primarily provides a global coordination function. The lower levels are Agency CA organizations that have primary responsibility for the registration, archiving, and dissemination of MDOs. As experience is gained and technology evolves, the CA Procedures will be extended to include enhanced services and their supporting protocols. In particular, it is anticipated that eventually CA organizations will be linked via networks on a global basis, and will provide requestors with online automated access to CA services. While this Recommendation does not preclude such operations, it also does not recommend the specific protocols to be used to ensure global compatibility of these services. These recommendations will be generated as experience is gained.

  17. Standard operating procedures for ESPEN guidelines and consensus papers.

    Science.gov (United States)

    Bischoff, Stephan C; Singer, Pierre; Koller, Michael; Barazzoni, Rocco; Cederholm, Tommy; van Gossum, André

    2015-12-01

    The ESPEN Guideline standard operating procedures (SOP) is based on the methodology provided by the Association of Scientific Medical Societies of Germany (AWMF), the Scottish Intercollegiate Guidelines Network (SIGN), and the Centre for Evidence-based Medicine at the University of Oxford. The SOP is valid and obligatory for all future ESPEN-sponsored guideline projects aiming to generate high-quality guidelines on a regular basis. The SOP aims to facilitate the preparation of guideline projects, to streamline the consensus process, to ensure quality and transparency, and to facilitate the dissemination and publication of ESPEN guidelines. To achieve this goal, the ESPEN Guidelines Editorial board (GEB) has been established headed by two chairmen. The GEB will support and supervise the guideline processes and is responsible for the strategic planning of ESPEN guideline activities. Key elements of the SOP are the generation of well-built clinical questions according to the PICO system, a systemic literature search, a classification of the selected literature according to the SIGN evidence levels providing an evidence table, and a clear and straight-forward consensus procedure consisting of online voting's and a consensus conference. Only experts who meet the obligation to disclosure any potential conflict of interests and who are not employed by the Industry can participate in the guideline process. All recommendations will be graded according to the SIGN grading and novel outcome models besides biomedical endpoints. This approach will further extent the leadership of ESPEN in creating up-to-date and suitable for implementation guidelines and in sharing knowledge on malnutrition and clinical nutrition. Copyright © 2015 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  18. Microwave-assisted versus conventional decomposition procedures applied to a ceramic potsherd standard reference material by inductively coupled plasma atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Papadopoulou, D.N.; Zachariadis, G.A.; Anthemidis, A.N.; Tsirliganis, N.C.; Stratis, J.A

    2004-03-03

    Inductively coupled plasma atomic emission spectrometry (ICP-AES) is a powerful, sensitive analytical technique with numerous applications in chemical characterization including that of ancient pottery, mainly due to its multi-element character, and the relatively short time required for the analysis. A critical step in characterization studies of ancient pottery is the selection of a suitable decomposition procedure for the ceramic matrix. The current work presents the results of a comparative study of six decomposition procedures applied on a standard ceramic potsherd reference material, SARM 69. The investigated decomposition procedures included three microwave-assisted decomposition procedures, one wet decomposition (WD) procedure by conventional heating, one combined microwave-assisted and conventional heating WD procedure, and one fusion procedure. Chemical analysis was carried out by ICP-AES. Five major (Si, Al, Fe, Ca, Mg), three minor (Mn, Ba, Ti) and two trace (Cu, Co) elements were determined and compared with their certified values. Quantitation was performed at two different spectral lines for each element and multi-element matrix-matched calibration standards were used. The recovery values for the six decomposition procedures ranged between 75 and 110% with a few notable exceptions. Data were processed statistically in order to evaluate the investigated decomposition procedures in terms of recovery, accuracy and precision, and eventually select the most appropriate one for ancient pottery analysis.

  19. Audit of radiation dose during balloon mitral valvuloplasty procedure

    Energy Technology Data Exchange (ETDEWEB)

    Livingstone, Roshan S [Department of Radiology, Christian Medical College, Vellore-632004, TN (India); Chandy, Sunil [Department of Cardiology, Christian Medical College, Vellore-632004, TN (India); Peace, B S Timothy [Department of Radiology, Christian Medical College, Vellore-632004, TN (India); George, Paul [Department of Cardiology, Christian Medical College, Vellore-632004, TN (India); John, Bobby [Department of Cardiology, Christian Medical College, Vellore-632004, TN (India); Pati, Purendra [Department of Cardiology, Christian Medical College, Vellore-632004, TN (India)

    2006-12-15

    Radiation doses to patients during cardiological procedures are of concern in the present day scenario. This study was intended to audit the radiation dose imparted to patients during the balloon mitral valvuloplasty (BMV) procedure. Thirty seven patients who underwent the BMV procedure performed using two dedicated cardiovascular machines were included in the study. The radiation doses imparted to patients were measured using a dose area product (DAP) meter. The mean DAP value for patients who underwent the BMV procedure from one machine was 19.16 Gy cm{sup 2} and from the other was 21.19 Gy cm{sup 2}. Optimisation of exposure parameters and radiation doses was possible for one machine with the use of appropriate copper filters and optimised exposure parameters, and the mean DAP value after optimisation was 9.36 Gy cm{sup 2}.

  20. Multicenter study on costs associated with two surgical procedures: GreenLight XPS 180 W versus the gold standard transurethral resection of the prostate.

    Science.gov (United States)

    Benejam-Gual, J M; Sanz-Granda, A; Budía, A; Extramiana, J; Capitán, C

    2014-01-01

    To analyze the costs associated with two surgical procedures for lower urinary tract symptoms secondary to benign prostatic hyperplasia: GreenLight XPS 180¦W versus the gold standard transurethral resection of the prostate. A multicenter, retrospective cost study was carried out from the National Health Service perspective, over a 3-month time period. Costs were broken down into pre-surgical, surgical and post-surgical phases. Data were extracted from records of patients operated sequentially, with IPSS=15, Qmax=15 mL/seg and a prostate volume of 40-80mL, adding only direct healthcare costs (€, 2013) associated with the procedure and management of complications. A total of 79 patients sequentially underwent GL XPS (n: 39) or TURP (n: 40) between July and October, 2013. Clinical outcomes were similar (94.9% and 92.5%, GL XPS and TURP, respectively) without significant differences (P=.67). The average direct cost per patient was reduced by €114 in GL XPS versus TURP patients; the cost was higher in the surgical phase with GL XPS (difference: €1,209; P<.001) but was lower in the post-surgical phase (difference: €-1,351; P<.001). The GreenLight XPS 180-W laser system is associated with a reduction in costs with respect to transurethral resection of prostate in the surgical treatment of LUTS secondary to PBH. This reduction is due to a shorter inpatient length of stay that offsets the cost of the new technology. Copyright © 2013 AEU. Published by Elsevier Espana. All rights reserved.

  1. Frey procedure combined with biliary diversion in chronic pancreatitis.

    Science.gov (United States)

    Merdrignac, Aude; Bergeat, Damien; Rayar, Michel; Harnoy, Yann; Turner, Kathleen; Courtin-Tanguy, Laetitia; Boudjema, Karim; Meunier, Bernard; Sulpice, Laurent

    2016-11-01

    The Frey procedure has become the standard operative treatment in chronic painful pancreatitis. Biliary diversion could be combined when associated with common bile duct obstruction. The aim of the present study was to evaluate the impact of the type of biliary diversion combined with the Frey procedure on late morbidity. The data from consecutive patients undergoing the Frey procedure and having a minimum follow-up of 2 years were extracted from a maintained prospective database. The mean endpoint was the rate of secondary biliary stricture after the Frey procedure combined with biliary diversion (bilioenteric anastomosis or common bile duct reinsertion in the resection cavity). Between 2006 and 2013, 55 consecutive patients underwent the Frey procedure. Twenty-nine patients had common bile duct obstruction (52.7%). The technique of biliary diversion resulted in bilioenteric anastomosis in 19 patients (65.5%) and common bile duct reinsertion in 10 patients (34.5%). Preoperative characteristics and early surgical outcomes were comparable. Pain control was similar. There was significantly more secondary biliary stricture after common bile duct reinsertion than after bilioenteric anastomosis (60% vs 11%, P = .008). Combined bilioenteric anastomosis during the Frey procedure is an efficient technique for treating common bile duct obstruction that complicates chronic painful pancreatitis. Bilioenteric anastomosis was associated with less secondary biliary stricture than common bile duct reinsertion in the pancreatic resection cavity. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. A new one-step procedure for pulmonary valve implantation of the melody valve: Simultaneous prestenting and valve implantation.

    Science.gov (United States)

    Boudjemline, Younes

    2018-01-01

    To describe a new modification, the one-step procedure, that allows interventionists to pre-stent and implant a Melody valve simultaneously. Percutaneous pulmonary valve implantation (PPVI) is the standard of care for managing patients with dysfunctional right ventricular outflow tract, and the approach is standardized. Patients undergoing PPVI using the one-step procedure were identified in our database. Procedural data and radiation exposure were compared to those in a matched group of patients who underwent PPVI using the conventional two-step procedure. Between January 2016 and January 2017, PPVI was performed in 27 patients (median age/range, 19.1/10-55 years) using the one-step procedure involving manual crimping of one to three bare metal stents over the Melody valve. The stent and Melody valve were delivered successfully using the Ensemble delivery system. No complications occurred. All patients had excellent hemodynamic results (median/range post-PPVI right ventricular to pulmonary artery gradient, 9/0-20 mmHg). Valve function was excellent. Median procedural and fluoroscopic times were 56 and 10.2 min, respectively, which significantly differed from those of the two-step procedure group. Similarly, the dose area product (DAP), and radiation time were statistically lower in the one-step group than in the two-step group (P step procedure is a safe modification that allows interventionists to prestent and implants the Melody valve simultaneously. It significantly reduces procedural and fluoroscopic times, and radiation exposure. © 2017 Wiley Periodicals, Inc.

  3. A comparative study on assessment procedures and metric properties of two scoring systems of the Coma Recovery Scale-Revised items: standard and modified scores.

    Science.gov (United States)

    Sattin, Davide; Lovaglio, Piergiorgio; Brenna, Greta; Covelli, Venusia; Rossi Sebastiano, Davide; Duran, Dunja; Minati, Ludovico; Giovannetti, Ambra Mara; Rosazza, Cristina; Bersano, Anna; Nigri, Anna; Ferraro, Stefania; Leonardi, Matilde

    2017-09-01

    The study compared the metric characteristics (discriminant capacity and factorial structure) of two different methods for scoring the items of the Coma Recovery Scale-Revised and it analysed scale scores collected using the standard assessment procedure and a new proposed method. Cross sectional design/methodological study. Inpatient, neurological unit. A total of 153 patients with disorders of consciousness were consecutively enrolled between 2011 and 2013. All patients were assessed with the Coma Recovery Scale-Revised using standard (rater 1) and inverted (rater 2) procedures. Coma Recovery Scale-Revised score, number of cognitive and reflex behaviours and diagnosis. Regarding patient assessment, rater 1 using standard and rater 2 using inverted procedures obtained the same best scores for each subscale of the Coma Recovery Scale-Revised for all patients, so no clinical (and statistical) difference was found between the two procedures. In 11 patients (7.7%), rater 2 noted that some Coma Recovery Scale-Revised codified behavioural responses were not found during assessment, although higher response categories were present. A total of 51 (36%) patients presented the same Coma Recovery Scale-Revised scores of 7 or 8 using a standard score, whereas no overlap was found using the modified score. Unidimensionality was confirmed for both score systems. The Coma Recovery Scale Modified Score showed a higher discriminant capacity than the standard score and a monofactorial structure was also supported. The inverted assessment procedure could be a useful evaluation method for the assessment of patients with disorder of consciousness diagnosis.

  4. Assessment of modal-pushover-based scaling procedure for nonlinear response history analysis of ordinary standard bridges

    Science.gov (United States)

    Kalkan, E.; Kwong, N.

    2012-01-01

    The earthquake engineering profession is increasingly utilizing nonlinear response history analyses (RHA) to evaluate seismic performance of existing structures and proposed designs of new structures. One of the main ingredients of nonlinear RHA is a set of ground motion records representing the expected hazard environment for the structure. When recorded motions do not exist (as is the case in the central United States) or when high-intensity records are needed (as is the case in San Francisco and Los Angeles), ground motions from other tectonically similar regions need to be selected and scaled. The modal-pushover-based scaling (MPS) procedure was recently developed to determine scale factors for a small number of records such that the scaled records provide accurate and efficient estimates of “true” median structural responses. The adjective “accurate” refers to the discrepancy between the benchmark responses and those computed from the MPS procedure. The adjective “efficient” refers to the record-to-record variability of responses. In this paper, the accuracy and efficiency of the MPS procedure are evaluated by applying it to four types of existing Ordinary Standard bridges typical of reinforced concrete bridge construction in California. These bridges are the single-bent overpass, multi-span bridge, curved bridge, and skew bridge. As compared with benchmark analyses of unscaled records using a larger catalog of ground motions, it is demonstrated that the MPS procedure provided an accurate estimate of the engineering demand parameters (EDPs) accompanied by significantly reduced record-to-record variability of the EDPs. Thus, it is a useful tool for scaling ground motions as input to nonlinear RHAs of Ordinary Standard bridges.

  5. Dysphagia in infants after open heart procedures.

    Science.gov (United States)

    Yi, Sook-Hee; Kim, Sang-Jun; Huh, June; Jun, Tae-Gook; Cheon, Hee Jung; Kwon, Jeong-Yi

    2013-06-01

    The aims of this study were to evaluate the prevalence and the clinical predictors of dysphagia and to determine the characteristics of videofluoroscopic swallowing study findings in infants after open heart procedures. This study is a retrospective review of 146 infants who underwent open heart surgery. The infants with dysphagia were compared with those without dysphagia. The videofluoroscopic swallowing study findings of the infants with dysphagia were also evaluated. Of the 146 infants who underwent open heart surgery, 35 (24.0%) had dysphagia symptoms. The infants with dysphagia had lower body weight at operation, more malformation syndromes, longer operation times, and more complex operations than did the infants without dysphagia. In addition, the infants with dysphagia required more time to achieve full oral feeding and had longer hospital stays. Thirty-three infants underwent videofluoroscopic swallowing study: 32 (97.0%) exhibited at least one abnormal finding among the videofluoroscopic swallowing study parameters and 21 (63.6%) exhibited tracheal aspiration. Given the high rate of aspiration in the infants who underwent open heart procedures, monitoring and prompt recognition of the signs and the risk factors of dysphagia may substantially improve infant care with oral feeding and reduce the duration of hospital stays.

  6. A systematic review of methods for quantifying serum testosterone in patients with prostate cancer who underwent castration.

    Science.gov (United States)

    Comas, I; Ferrer, R; Planas, J; Celma, A; Regis, L; Morote, J

    2018-03-01

    The clinical practice guidelines recommend measuring serum testosterone in patients with prostate cancer (PC) who undergo castration. The serum testosterone concentration should be IA) has become widespread, although their metrological characteristics do not seem appropriate for quantifying low testosterone concentrations. The objective of this review is to analyse the methods for quantifying testosterone and to establish whether there is scientific evidence that justifies measuring it in patients with PC who undergo castration, through liquid chromatography attached to a mass spectrometry in tandem (LC-MSMS). We performed a search in PubMed with the following MeSH terms: measurement, testosterone, androgen suppression and prostate cancer. We selected 12 studies that compared the metrological characteristics of various methods for quantifying serum testosterone compared with MS detection methods. IAs are standard tools for measuring testosterone levels; however, there is evidence that IAs lack accuracy and precision for quantifying low concentrations. Most chemiluminescent IAs overestimate their concentration, especially below 100ng/dL. The procedures that use LC-MSMS have an adequate lower quantification limit and proper accuracy and precision. We found no specific evidence in patients with PC who underwent castration. LC-MSMS is the appropriate method for quantifying low serum testosterone concentrations. We need to define the level of castration with this method and the optimal level related to better progression of the disease. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Constructing an exposure chart: step by step (based on standard procedures)

    International Nuclear Information System (INIS)

    David, Jocelyn L; Cansino, Percedita T.; Taguibao, Angileo P.

    2000-01-01

    An exposure chart is very important in conducting radiographic inspection of materials. By using an accurate exposure chart, an inspector is able to avoid a trial and error way of determining correct time to expose a specimen, thereby producing a radiograph that has an acceptable density based on a standard. The chart gives the following information: x-ray machine model and brand, distance of the x-ray tube from the film, type and thickness of intensifying screens, film type, radiograph density, and film processing conditions. The methods of preparing an exposure chart are available in existing radiographic testing manuals. These described methods are presented in step by step procedures, covering the actual laboratory set-up, data gathering, computations, and transformation of derived data into Characteristic Curve and Exposure Chart

  8. Image-guided procedures in brain biopsy.

    Science.gov (United States)

    Fujita, K; Yanaka, K; Meguro, K; Narushima, K; Iguchi, M; Nakai, Y; Nose, T

    1999-07-01

    Image-guided procedures, such as computed tomography (CT)-guided stereotactic and ultrasound-guided methods, can assist neurosurgeons in localizing the relevant pathology. The characteristics of image-guided procedures are important for their appropriate use, especially in brain biopsy. This study reviewed the results of various image-guided brain biopsies to ascertain the advantages and disadvantages. Brain biopsies assisted by CT-guided stereotactic, ultrasound-guided, Neuronavigator-guided, and the combination of ultrasound and Neuronavigator-guided procedures were carried out in seven, eight, one, and three patients, respectively. Four patients underwent open biopsy without a guiding system. Twenty of 23 patients had a satisfactory diagnosis after the initial biopsy. Three patients failed to have a definitive diagnosis after the initial procedure, one due to insufficient volume sampling after CT-guided procedure, and two due to localization failure by ultrasound because the lesions were nonechogenic. All patients who underwent biopsy using the combination of ultrasound and Neuronavigator-guided methods had a satisfactory result. The CT-guided procedure provided an efficient method of approaching any intracranial target and was appropriate for the diagnosis of hypodense lesions, but tissue sampling was sometimes not sufficient to achieve a satisfactory diagnosis. The ultrasound-guided procedure was suitable for the investigation of hyperdense lesions, but was difficult to localize nonechogenic lesions. The combination of ultrasound and Neuronavigator methods improved the diagnostic accuracy even in nonechogenic lesions such as malignant lymphoma. Therefore, it is essential to choose the most appropriate guiding method for brain biopsy according to the radiological nature of the lesions.

  9. The Cox-maze IV procedure in its second decade: still the gold standard?

    Science.gov (United States)

    Ruaengsri, Chawannuch; Schill, Matthew R; Khiabani, Ali J; Schuessler, Richard B; Melby, Spencer J; Damiano, Ralph J

    2018-04-01

    Atrial fibrillation (AF) is the most common cardiac arrhythmia and the treatment options include medical treatment and catheter-based or surgical interventions. AF is a major cause of stroke, and its prevalence is increasing. The surgical treatment of AF has been revolutionized over the past 2 decades through surgical innovation and improvements in endoscopic imaging, ablation technology and surgical instrumentation. The Cox-maze (CM) procedure, which was developed by James Cox and introduced clinically in 1987, is a procedure in which multiple incisions are created in both the left and the right atria to eliminate AF while allowing the sinus impulse to reach the atrioventricular node. This procedure became the gold standard for the surgical treatment of AF. Its latest iteration is termed the CM IV and was introduced in 2002. The CM IV replaced the previous cut-and-sew method (CM III) by replacing most of the incisions with a combination of bipolar radiofrequency and cryoablation. The use of ablation technologies, made the CM IV technically easier, faster and more amenable to minimally invasive approaches. The aims of this article are to review the indications and preoperative planning for the CM IV, to describe the operative technique and to review the literature including comparisons of the CM IV with the previous cut-and-sew method. Finally, this review explores future directions for the surgical treatment of patients with AF.

  10. Dataset and standard operating procedure for newborn screening of six lysosomal storage diseases: By tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Susan Elliott

    2016-09-01

    Full Text Available In this data article we provide a detailed standard operating procedure for performing a tandem mass spectrometry, multiplex assay of 6 lysosomal enzymes for newborn screening of the lysosomal storage diseases Mucopolysaccharidosis-I, Pompe, Fabry, Niemann-Pick-A/B, Gaucher, and Krabbe, (Elliott, et al., 2016 [1]. We also provide the mass spectrometry peak areas for the product and internal standard ions typically observed with a dried blood spot punch from a random newborn, and we provide the daily variation of the daily mean activities for all 6 enzymes.

  11. Circulating S100B and Adiponectin in Children Who Underwent Open Heart Surgery and Cardiopulmonary Bypass

    Directory of Open Access Journals (Sweden)

    Alessandro Varrica

    2015-01-01

    Full Text Available Background. S100B protein, previously proposed as a consolidated marker of brain damage in congenital heart disease (CHD newborns who underwent cardiac surgery and cardiopulmonary bypass (CPB, has been progressively abandoned due to S100B CNS extra-source such as adipose tissue. The present study investigated CHD newborns, if adipose tissue contributes significantly to S100B serum levels. Methods. We conducted a prospective study in 26 CHD infants, without preexisting neurological disorders, who underwent cardiac surgery and CPB in whom blood samples for S100B and adiponectin (ADN measurement were drawn at five perioperative time-points. Results. S100B showed a significant increase from hospital admission up to 24 h after procedure reaching its maximum peak (P0.05 have been found all along perioperative monitoring. ADN/S100B ratio pattern was identical to S100B alone with the higher peak at the end of CPB and remained higher up to 24 h from surgery. Conclusions. The present study provides evidence that, in CHD infants, S100B protein is not affected by an extra-source adipose tissue release as suggested by no changes in circulating ADN concentrations.

  12. Compliance determination procedures for environmental radiation protection standards for uranium recovery facilities 40 CFR part 190

    International Nuclear Information System (INIS)

    1982-03-01

    Uranium Milling operations are licensed by the Nuclear Regulatory Commission and by some States in agreement with the Commission. The radiation dose to any individual from the operation of facilities within the uranium fuel cycle is limited to levels set by the Environmental Protection Agency. These levels are contained in the EPA Environmental Radiation Protection Standards for Nuclear Power Operations, in Part 190 of Title 40 of the Code of Federal Regulations (40 CFR Part 190). This report describes the procedures used within NRC's Uranium Recovery Licensing Branch for evaluating compliance with these regulations for uranium milling operations. The report contains descriptions of these procedures, dose factors for evaluating environmental measurement data, and guidance to the NRC staff reviewer

  13. The CIPM list of recommended frequency standard values: guidelines and procedures

    Science.gov (United States)

    Riehle, Fritz; Gill, Patrick; Arias, Felicitas; Robertsson, Lennart

    2018-04-01

    A list of standard reference frequency values (LoF) of quantum transitions from the microwave to the optical regime has been recommended by the International Committee for Weights and Measures (Comité international des poids et mesures, CIPM) for use in basic research, technology, and for the metrology of time, frequency and length. The CIPM LoF contains entries that are recommended as secondary representations of the second in the International System of Units, and entries that can be used to serve as realizations of the definition of the metre. The historical perspective that led to the CIPM LoF is outlined. Procedures have been developed for updating existing, and validating new, entries into the CIPM LoF. The CIPM LoF might serve as an entry for a future redefinition of the second by an optical transition.

  14. Documentation for assessment of modal pushover-based scaling procedure for nonlinear response history analysis of "ordinary standard" bridges

    Science.gov (United States)

    Kalkan, Erol; Kwong, Neal S.

    2010-01-01

    The earthquake engineering profession is increasingly utilizing nonlinear response history analyses (RHA) to evaluate seismic performance of existing structures and proposed designs of new structures. One of the main ingredients of nonlinear RHA is a set of ground-motion records representing the expected hazard environment for the structure. When recorded motions do not exist (as is the case for the central United States), or when high-intensity records are needed (as is the case for San Francisco and Los Angeles), ground motions from other tectonically similar regions need to be selected and scaled. The modal-pushover-based scaling (MPS) procedure recently was developed to determine scale factors for a small number of records, such that the scaled records provide accurate and efficient estimates of 'true' median structural responses. The adjective 'accurate' refers to the discrepancy between the benchmark responses and those computed from the MPS procedure. The adjective 'efficient' refers to the record-to-record variability of responses. Herein, the accuracy and efficiency of the MPS procedure are evaluated by applying it to four types of existing 'ordinary standard' bridges typical of reinforced-concrete bridge construction in California. These bridges are the single-bent overpass, multi span bridge, curved-bridge, and skew-bridge. As compared to benchmark analyses of unscaled records using a larger catalog of ground motions, it is demonstrated that the MPS procedure provided an accurate estimate of the engineering demand parameters (EDPs) accompanied by significantly reduced record-to-record variability of the responses. Thus, the MPS procedure is a useful tool for scaling ground motions as input to nonlinear RHAs of 'ordinary standard' bridges.

  15. Late outcomes after the Cox maze IV procedure for atrial fibrillation.

    Science.gov (United States)

    Henn, Matthew C; Lancaster, Timothy S; Miller, Jacob R; Sinn, Laurie A; Schuessler, Richard B; Moon, Marc R; Melby, Spencer J; Maniar, Hersh S; Damiano, Ralph J

    2015-11-01

    The Cox maze IV procedure (CMPIV) has been established as the gold standard for surgical ablation; however, late outcomes using current consensus definitions of treatment failure have not been well described. To compare to reported outcomes of catheter-based ablation, we report our institutional outcomes of patients who underwent a left-sided or biatrial CMPIV at 5 years of follow-up. Between January 2002 and September 2014, data were collected prospectively on 576 patients with AF who underwent a CMPIV (n = 532) or left-sided CMPIV (n = 44). Perioperative variables and long-term freedom from AF, with and without AADs, were compared in multiple subgroups. Follow-up at any time point was 89%. At 5 years, overall freedom from AF was 93 of 119 (78%), and freedom from AF off AADs was 77 of 177 (66%). No differences were found in freedom from AF, with or without AADs, at 1, 2, 3, 4, and 5 years for patients with paroxysmal AF (n = 204) versus with persistent/longstanding persistent AF (n = 305), or for those who underwent standalone versus a concomitant CMP. Duration of preoperative AF and hospital length of stay were the best predictors of failure at 5 years. The outcomes of the CMPIV remain good at late follow-up. The type of preoperative AF or the addition of a concomitant procedure did not affect late success. The results of the CMPIV remain superior to those reported for catheter ablation and other forms of surgical AF ablation, especially for patients with persistent or longstanding AF. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  16. Standardized procedure for eddy-current testing of stainless steel, thin-walled nuclear fuel element cladding tubes

    Energy Technology Data Exchange (ETDEWEB)

    Barat, P; Raj, B; Bhattacharya, D K [Reactor Research Centre, Kalpakkam (India)

    1982-10-01

    Thin-walled nuclear fuel cladding tubes made of AISI 316 stainless steel have been examined by eddy-current testing. Standardization of the procedures has required investigations on optimizing the test frequency, finding a method to locate a defect with respect to the probe reference end, and the use of standard defects and sequential metallography of natural defects detected by eddy-current testing, to understand the influence of the nature of defects on the impedance output signals. Test frequency and method of locating the defect were optimized by the use of standard defects made by machining in reference cladding tubes. Subsequent metallography of natural defects detected by eddy-current testing revealed mainly clusters of inclusions but also other types of defects. The effect of the distribution of inclusions along the length of the tube on the impedance output is discussed.

  17. [Falling Short of Minimum Volume Standards, Exemptions and Their Consequences from 2018 Onwards. Complex Procedures on Oesophagus and Pancreas in German Hospitals from 2006 to 2014].

    Science.gov (United States)

    de Cruppé, Werner; Geraedts, Max

    2018-03-16

    The minimum volume standards for hospitals in Germany, in force since 2004, provide four exemptions for non-complying hospitals. This study investigates the extent and importance of these exemptions for complex procedures on the oesophagus and pancreas for all non-complying hospitals and for the revised minimum volume regulations in force since the beginning of 2018. Longitudinal, descriptive analyses of data on minimum volume standards and their exemptions for complex procedures on the oesophagus and pancreas, as presented by the hospital quality report cards of the reporting years from 2006 to 2014. For each year and both procedures, about 120 hospitals with some 500 cases report non-compliance with the minimum volume standards. Of these a third report no exemptions (with 180 procedures), a third state emergencies (110), and another third report exemptions due to internal hospital restructuring (210). Ensuring geographical access to care as an exemption is of no importance. After the three year exemption period for installation of a new service line, 20% of the hospitals with procedures on the oesophagus and 30% on the pancreas complied with the minimum volume standards. After the two-year period for staff realignment, the figures were 40 and 50%, respectively. Exemptions do not entirely explain all procedures performed by hospitals not complying with the minimum volume standards. The revised minimum volume regulations' restructuring of exemptions to "emergencies" and "new or renewed service lines" with a two year exemption period, are concordant with the empirical findings of this study. Georg Thieme Verlag KG Stuttgart · New York.

  18. Electronic Procedures for Medical Operations

    Science.gov (United States)

    2015-01-01

    Electronic procedures are replacing text-based documents for recording the steps in performing medical operations aboard the International Space Station. S&K Aerospace, LLC, has developed a content-based electronic system-based on the Extensible Markup Language (XML) standard-that separates text from formatting standards and tags items contained in procedures so they can be recognized by other electronic systems. For example, to change a standard format, electronic procedures are changed in a single batch process, and the entire body of procedures will have the new format. Procedures can be quickly searched to determine which are affected by software and hardware changes. Similarly, procedures are easily shared with other electronic systems. The system also enables real-time data capture and automatic bookmarking of current procedure steps. In Phase II of the project, S&K Aerospace developed a Procedure Representation Language (PRL) and tools to support the creation and maintenance of electronic procedures for medical operations. The goal is to develop these tools in such a way that new advances can be inserted easily, leading to an eventual medical decision support system.

  19. Abdominoplasty: Risk Factors, Complication Rates, and Safety of Combined Procedures.

    Science.gov (United States)

    Winocour, Julian; Gupta, Varun; Ramirez, J Roberto; Shack, R Bruce; Grotting, James C; Higdon, K Kye

    2015-11-01

    Among aesthetic surgery procedures, abdominoplasty is associated with a higher complication rate, but previous studies are limited by small sample sizes or single-institution experience. A cohort of patients who underwent abdominoplasty between 2008 and 2013 was identified from the CosmetAssure database. Major complications were recorded. Univariate and multivariate analysis was performed evaluating risk factors, including age, smoking, body mass index, sex, diabetes, type of surgical facility, and combined procedures. The authors identified 25,478 abdominoplasties from 183,914 procedures in the database. Of these, 8,975 patients had abdominoplasty alone and 16,503 underwent additional procedures. The number of complications recorded was 1,012 (4.0 percent overall rate versus 1.4 percent in other aesthetic surgery procedures). Of these, 31.5 percent were hematomas, 27.2 percent were infections and 20.2 percent were suspected or confirmed venous thromboembolism. On multivariate analysis, significant risk factors (p procedures (1.5), and procedure performance in a hospital or surgical center versus office-based surgical suite (1.6). Combined procedures increased the risk of complication (abdominoplasty alone, 3.1 percent; with liposuction, 3.8 percent; breast procedure, 4.3 percent; liposuction and breast procedure, 4.6 percent; body-contouring procedure, 6.8 percent; liposuction and body-contouring procedure, 10.4 percent). Abdominoplasty is associated with a higher complication rate compared with other aesthetic procedures. Combined procedures can significantly increase complication rates and should be considered carefully in higher risk patients. Risk, II.

  20. Review of cause-based decision tree approach for the development of domestic standard human reliability analysis procedure in low power/shutdown operation probabilistic safety assessment

    International Nuclear Information System (INIS)

    Kang, D. I.; Jung, W. D.

    2003-01-01

    We review the Cause-Based Decision Tree (CBDT) approach to decide whether we incorporate it or not for the development of domestic standard Human Reliability Analysis (HRA) procedure in low power/shutdown operation Probabilistic Safety Assessment (PSA). In this paper, we introduce the cause based decision tree approach, quantify human errors using it, and identify merits and demerits of it in comparision with previously used THERP. The review results show that it is difficult to incorporate the CBDT method for the development of domestic standard HRA procedure in low power/shutdown PSA because the CBDT method need for the subjective judgment of HRA analyst like as THERP. However, it is expected that the incorporation of the CBDT method into the development of domestic standard HRA procedure only for the comparision of quantitative HRA results will relieve the burden of development of detailed HRA procedure and will help maintain consistent quantitative HRA results

  1. A Guide for Developing Standard Operating Job Procedures for the Tertiary Chemical Treatment - Lime Precipitation Process Wastewater Treatment Facility. SOJP No. 6.

    Science.gov (United States)

    Petrasek, Al, Jr.

    This guide describes the standard operating job procedures for the tertiary chemical treatment - lime precipitation process of wastewater treatment plants. Step-by-step instructions are given for pre-start up, start-up, continuous operation, and shut-down procedures. In addition, some theoretical material is presented along with some relevant…

  2. Bentall Procedure Using Cryopreserved Valved Aortic Homografts

    Science.gov (United States)

    Christenson, Jan T.; Sierra, Jorge; Trindade, Pedro T.; Didier, Dominique; Kalangos, Afksendiyos

    2004-01-01

    The Bentall procedure is the standard operation for patients who have lesions of the ascending aorta associated with aortic valve disease. In many cases, however, mechanical prosthetic conduits are not suitable. There are few reports in the English-language medical literature concerning the mid- to long-term outcome of Bentall operations with cryopreserved homografts. Therefore, we reviewed our experience with this procedure and valved homografts. From January 1997 through December 2002, 21 patients underwent a Bentall operation with cryopreserved homografts at our institution. There were 14 males and 7 females; the mean age was 36 ± 21 years (range, 15–74 years). Eleven patients had undergone previous aortic valve surgery. All patients had aortic dilatation or aneurysms involving the ascending aorta. Indications for surgery included aortic valve stenosis or insufficiency, and aortic valve endocarditis (native valve or prosthetic). One patient had Takayasu's arteritis and 3 had Marfan syndrome. There was 1 hospital death (due to sepsis), but no other major postoperative complications. The mean hospital stay was 14 ± 7 days. Follow-up echocardiographic and computed tomographic scans were performed yearly. The mean follow-up was 34 months (6–72 months). Follow-up imaging revealed no calcifications or degenerative processes related to the homograft. Four patients had minimal valve regurgitation. Two patients died during follow-up. The 3-year actuarial survival rate was 85.7%. Our data suggest that the Bentall procedure with a valved homograft conduit is a safe procedure with excellent mid- to long-term results, comparable to results reported with aortic valve replacement with a homograft. PMID:15745290

  3. Development of a standardized training course for laparoscopic procedures using Delphi methodology.

    Science.gov (United States)

    Bethlehem, Martijn S; Kramp, Kelvin H; van Det, Marc J; ten Cate Hoedemaker, Henk O; Veeger, Nicolaas J G M; Pierie, Jean Pierre E N

    2014-01-01

    Content, evaluation, and certification of laparoscopic skills and procedure training lack uniformity among different hospitals in The Netherlands. Within the process of developing a new regional laparoscopic training curriculum, a uniform and transferrable curriculum was constructed for a series of laparoscopic procedures. The aim of this study was to determine regional expert consensus regarding the key steps for laparoscopic appendectomy and cholecystectomy using Delphi methodology. Lists of suggested key steps for laparoscopic appendectomy and cholecystectomy were created using surgical textbooks, available guidelines, and local practice. A total of 22 experts, working for teaching hospitals throughout the region, were asked to rate the suggested key steps for both procedures on a Likert scale from 1-5. Consensus was reached with Crohnbach's α ≥ 0.90. Of the 22 experts, 21 completed and returned the survey (95%). Data analysis already showed consensus after the first round of Delphi on the key steps for laparoscopic appendectomy (Crohnbach's α = 0.92) and laparoscopic cholecystectomy (Crohnbach's α = 0.90). After the second round, 15 proposed key steps for laparoscopic appendectomy and 30 proposed key steps for laparoscopic cholecystectomy were rated as important (≥4 by at least 80% of the expert panel). These key steps were used for the further development of the training curriculum. By using the Delphi methodology, regional consensus was reached on the key steps for laparoscopic appendectomy and cholecystectomy. These key steps are going to be used for standardized training and evaluation purposes in a new regional laparoscopic curriculum. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  4. PROCEDURE FOR ANALYSIS COMPLIANCE WITH QUALITY STANDARDS OFFER OF THE BUFFET RESTAURANT CASONA MELIA SANTIAGO DE CUBA

    Directory of Open Access Journals (Sweden)

    Oscar Parada-Pérez

    2016-01-01

    Full Text Available The company hotel Cuban faces the challenge of the competitiveness and the client’s satisfaction in an environment that demands of actions that they assure the quality. This article has as objective to show the application of a procedure for the evaluation of the standards of quality of the offer in the restaurant buffet La Casona of the Hotel Meliá Santiago de Cuba. The results achieved by the application of the procedure allow to perfect the process of taking of decisions and it contributes to the efficiency of the hotel and the elevation of the quality of the service. 

  5. Safety and Tolerability of Transitioning from Cangrelor to Ticagrelor in Patients Who Underwent Percutaneous Coronary Intervention.

    Science.gov (United States)

    Badreldin, Hisham A; Carter, Danielle; Cook, Bryan M; Qamar, Arman; Vaduganathan, Muthiah; Bhatt, Deepak L

    2017-08-01

    The 3 phase 3 CHAMPION (Cangrelor vs Standard Therapy to Achieve Optimal Management of Platelet Inhibition) trials collectively demonstrated the safety of transitioning from cangrelor, a potent, parenteral rapidly-acting P2Y 12 inhibitor, to clopidogrel in patients who underwent percutaneous coronary intervention (PCI). However, variation in timing of therapy, site-specific binding, and drug half-lives may theoretically complicate switching to other oral P2Y 12 inhibitors. Since regulatory approval, limited data are available regarding the "real-world" safety and tolerability of transitioning to these more potent oral P2Y 12 antagonists. From November 2015 to January 2017, we evaluated the clinical profiles and efficacy and safety outcomes in cangrelor-treated patients who underwent PCI transitioned to clopidogrel (n = 42) or ticagrelor (n = 82) at a large, tertiary care center. Most patients receiving cangrelor underwent PCI with a drug-eluting stent for acute coronary syndrome via a radial approach in the background of unfractionated heparin. Stent thrombosis within 48 hours was rare and occurred in 1 patient treated with ticagrelor. Global Use of Strategies to Open Occluded Coronary Arteries-defined bleeding occurred in 20% of patients switched to ticagrelor and 29% of patients switched to clopidogrel, but none were severe or life-threatening. In conclusion, rates of stent thrombosis and severe/life-threatening bleeding were low and comparable with those identified in the CHAMPION program, despite use of more potent oral P2Y 12 inhibition. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Rendezvous technique for recanalization of long-segmental chronic total occlusion above the knee following unsuccessful standard angioplasty.

    Science.gov (United States)

    Cao, Jun; Lu, Hai-Tao; Wei, Li-Ming; Zhao, Jun-Gong; Zhu, Yue-Qi

    2016-04-01

    To assess the technical feasibility and efficacy of the rendezvous technique, a type of subintimal retrograde wiring, for the treatment of long-segmental chronic total occlusions above the knee following unsuccessful standard angioplasty. The rendezvous technique was attempted in eight limbs of eight patients with chronic total occlusions above the knee after standard angioplasty failed. The clinical symptoms and ankle-brachial index were compared before and after the procedure. At follow-up, pain relief, wound healing, limb salvage, and the presence of restenosis of the target vessels were evaluated. The rendezvous technique was performed successfully in seven patients (87.5%) and failed in one patient (12.5%). Foot pain improved in all seven patients who underwent successful treatment, with ankle-brachial indexes improving from 0.23 ± 0.13 before to 0.71 ± 0.09 after the procedure (P rendezvous technique is a feasible and effective treatment for chronic total occlusions above the knee when standard angioplasty fails. © The Author(s) 2015.

  7. 77 FR 65823 - Control of Air Pollution From Aircraft and Aircraft Engines; Emission Standards and Test Procedures

    Science.gov (United States)

    2012-10-31

    ... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Parts 87 [EPA-HQ-OAR-2010-0687; FRL-9678-1] RIN 2060-AO70 Control of Air Pollution From Aircraft and Aircraft Engines; Emission Standards and Test Procedures Correction In rule document 2012-13828 appearing on pages 36341-36386 in the issue of Monday, June 18, 2012, make the following corrections: Sec. 87.2...

  8. Management of recurrent stress urinary incontinence after burch and sling procedures.

    Science.gov (United States)

    Zimmern, Philippe E; Gormley, E Ann; Stoddard, Anne M; Lukacz, Emily S; Sirls, Larry; Brubaker, Linda; Norton, Peggy; Oliphant, Sallie S; Wilson, Tracey

    2016-03-01

    To examine treatment options selected for recurrent stress urinary incontinence (rSUI) in follow-up after Burch, autologous fascial and synthetic midurethral sling (MUS) procedures. We performed a secondary analysis of the SISTER and ToMUS trials of participants who underwent primary stress urinary incontinence (SUI) treatment (without prior SUI surgery or concomitant procedures). Using Kaplan-Meier analysis, retreatment-free survival rates by initial surgical procedure were compared. Mean MESA (Medical Epidemiologic and Social Aspects of Aging) stress index was also compared between those retreated for rSUI compared to those not retreated. Half of the women in the SISTEr trial met inclusion criteria for this analysis (329/655, 174 Burch and 155 fascial sling), as did 444/597 (74%) of subjects in ToMUS (221 transobturator midurethral sling (TMUS), and 223 retropubic midurethral sling (RMUS). Types of surgical retreatment included autologous fascial sling (19), synthetic sling (1), and bulking agent (18). Five-year retreatment free survival rates (and standard errors) were 87% (3%), 96% (2%), 97% (1%), and 99% (0.7%) for Burch, autologous fascial sling, TMUS, and RMUS groups respectively (P < 0.0001). For all index surgery groups, the mean MESA stress index at last visit prior to retreatment for those retreated (n = 23) was significantly higher than mean MESA stress index at last visit for those not retreated (n = 645) (P < 0.0001). In these cohorts, 6% of women after standard anti-incontinence procedures were retreated within 5 years, mostly with injection therapy or autologous fascial sling. Not all women with rSUI chose surgical retreatment. © 2015 Wiley Periodicals, Inc.

  9. Standards for holdup measurement

    International Nuclear Information System (INIS)

    Zucker, M.S.

    1982-01-01

    Holdup measurement, needed for material balance, depend intensively on standards and on interpretation of the calibration procedure. More than other measurements, the calibration procedure using the standard becomes part of the standard. Standards practical for field use and calibration techniques have been developed. While accuracy in holdup measurements is comparatively poor, avoidance of bias is a necessary goal

  10. Standard operating procedures in the disorders of orgasm and ejaculation.

    Science.gov (United States)

    McMahon, Chris G; Jannini, Emmanuele; Waldinger, Marcel; Rowland, David

    2013-01-01

    Ejaculatory/orgasmic disorders are common male sexual dysfunctions and include premature ejaculation (PE), inhibited ejaculation, anejaculation, retrograde ejaculation, and anorgasmia. To provide recommendations and guidelines of the current state-of-the-art knowledge for management of ejaculation/orgasmic disorders in men as standard operating procedures (SOPs) for the treating health care professional. The International Society of Sexual Medicine Standards Committee assembled over 30 multidisciplinary experts to establish SOPs for various male and female sexual medicine topics. The SOP for the management of disorders of orgasm and ejaculation represents the opinion of four experts from four countries developed in a process over a 2-year period. Expert opinion was based on grading of evidence-based medical literature, limited expert opinion, widespread internal committee discussion, public presentation, and debate. PE management is largely dependent upon etiology. Lifelong PE is best managed with PE pharmacotherapy (selective serotonin reuptake inhibitors and/or topical anesthetics). The management of acquired PE is etiology specific and may include erectile dysfunction (ED) pharmacotherapy in men with comorbid ED. All men seeking treatment for PE should receive basic psychosexual education. Graded behavioral therapy is indicated when psychogenic or relationship factors are present and is often best combined with PE pharmacotherapy in an integrated treatment program. Delayed ejaculation, anejaculation, and/or anorgasmia may have a biogenic and/or psychogenic etiology. Men with age-related penile hypoanesthesia should be educated, reassured, and instructed in revised sexual techniques which maximize arousal. Retrograde ejaculation is managed by education, patient reassurance, and pharmacotherapy. Additional research is required to further the understanding of the disorders of ejaculation and orgasm. © 2012 International Society for Sexual Medicine.

  11. Development of quality standards of medicinal mistletoe – Helicanthes elastica (Desr. Danser employing Pharmacopoeial procedures

    Directory of Open Access Journals (Sweden)

    K.N. Sunil Kumar

    2016-11-01

    Full Text Available Helicanthes elastica (Desr. Danser (Loranthaceae, commonly known as Indian mango mistletoe, is a parasitic shrub found widely growing on mango trees in southern India. Development of monographic quality standards is need of the hour for Pharmacopoeial/extra-Pharmacopoeial and folk medicinal plants. Systematic pharmacognostical evaluation of leaves of H. elastica has been carried out employing Pharmacopoeial procedures of testing herbal drugs. Macro–microscopic features of H. elastica leaf were recorded. Ethanolic extract was tested positive for alkaloids, steroids, carbohydrates, tannins, saponins and phenols. HPTLC fingerprint profile was developed for the identification of extracts using reference standard β-sitosterol glucoside. Results of the present investigation would serve as a source of pharmacognostical information and a document to control the quality of H. elastica (Desr. Danser. Keywords: HPTLC, Mango mistletoe, Medicinal plant monograph, Quality control

  12. The primary exposure standard of ENEA for medium energy X-ray: characteristics and measurements procedures

    International Nuclear Information System (INIS)

    Laitano, R.F.; Toni, M.P.

    1983-01-01

    A description is given of a medium energy X-ray free-air chamber used, as primary exposure standard, at the Laboratorio di Metrologia delle Radiazioni Ionizzanti of the Enea in Italy. The main features of an X-ray facility for the production of radiation between 40 KeV and 400 KeV are also described. The measurements procedures are then analyzed with respect to the realization of the exposure unit in the relevant energy range. Finally the results of some international comparisons are reported

  13. Medical Procedures and Risk for Sporadic Creutzfeldt-Jakob Disease, Japan, 1999–2008

    Science.gov (United States)

    Hamaguchi, Tsuyoshi; Noguchi-Shinohara, Moeko; Nozaki, Ichiro; Nakamura, Yosikazu; Sato, Takeshi; Kitamoto, Tetsuyuki; Mizusawa, Hidehiro

    2009-01-01

    To elucidate the association between medical procedures and sporadic Creutzfeldt-Jakob disease (sCJD), we analyzed medical procedures (any surgical procedure, neurosurgery, ophthalmic surgery, and blood transfusion) for patients registered by the CJD Surveillance Committee in Japan during 1999–2008. We conducted an age-stratified case–control study with 753 sCJD patients and 210 controls and a study of patients who underwent neurosurgical or ophthalmic surgical procedures at the same hospital. Although the control group was relatively small, no evidence was found that prion disease was transmitted through the investigated medical procedures before onset of sCJD. After onset of sCJD, 4.5% of the sCJD patients underwent operations, including neurosurgical for 0.8% and ophthalmic for 1.9%; no special precautions against transmission of prion diseases were taken. Fortunately, we have not identified patients with prion disease attributed to these operations. Our findings indicate that surgical procedures or blood transfusion had little effect on the incidence of sCJD. PMID:19193271

  14. A standardized procedure for eddy-current testing of stainless steel, thin-walled nuclear fuel element cladding tubes

    International Nuclear Information System (INIS)

    Barat, P.; Raj, B.; Bhattacharya, D.K.

    1982-01-01

    Thin-walled nuclear fuel cladding tubes made of AISI 316 stainless steel have been examined by eddy-current testing. Standardization of the procedures has required investigations on optimizing the test frequency, finding a method to locate a defect with respect to the probe reference end, and the use of standard defects and sequential metallography of natural defects detected by eddy-current testing, to understand the influence of the nature of defects on the impedance output signals. Test frequency and method of locating the defect were optimized by the use of standard defects made by machining in reference cladding tubes. Subsequent metallography of natural defects detected by eddy-current testing revealed mainly clusters of inclusions but also other types of defects. The effect of the distribution of inclusions along the length of the tube on the impedance output is discussed. (author)

  15. A standard operating procedure for the surgical implantation of transmitters in juvenile salmonids

    Science.gov (United States)

    Liedtke, T.L.; Beeman, J.W.; Gee, L.P.

    2012-01-01

    Biotelemetry is a useful tool to monitor the movements of animals and is widely applied in fisheries research. Radio or acoustic technology can be used, depending on the study design and the environmental conditions in the study area. A broad definition of telemetry also includes the use of Passive Integrated Transponder (PIT) tags, either separately or with a radio or acoustic transmitter. To use telemetry, fish must be equipped with a transmitter. Although there are several attachment procedures available, surgical implantation of transmitters in the abdominal cavity is recognized as the best technique for long-term telemetry studies in general (Stasko and Pincock, 1977; Winter, 1996; Jepsen, 2003), and specifically for juvenile salmonids, Oncorhynchus spp. (Adams and others, 1998a, 1998b; Martinelli and others, 1998; Hall and others, 2009). Studies that use telemetry assume that the processes by which the animals are captured, handled, and tagged, as well as the act of carrying the transmitter, will have minimal effect on their behavior and performance. This assumption, commonly stated as a lack of transmitter effects, must be valid if telemetry studies are to describe accurately the movements and behavior of an entire population of interest, rather than the subset of that population that carries transmitters. This document describes a standard operating procedure (SOP) for surgical implantation of radio or acoustic transmitters in juvenile salmonids. The procedures were developed from a broad base of published information, laboratory experiments, and practical experience in tagging thousands of fish for numerous studies of juvenile salmon movements near Columbia River and Snake River hydroelectric dams. Staff from the Western Fisheries Research Center's Columbia River Research Laboratory (CRRL) frequently have used telemetry studies to evaluate new structures or operations at hydroelectric dams in the Columbia River Basin, and these evaluations typically

  16. Test Standard Revision Update: JESD57, "Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation"

    Science.gov (United States)

    Lauenstein, Jean-Marie

    2015-01-01

    The JEDEC JESD57 test standard, Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation, is undergoing its first revision since 1996. In this talk, we place this test standard into context with other relevant radiation test standards to show its importance for single-event effect radiation testing for space applications. We show the range of industry, government, and end-user party involvement in the revision. Finally, we highlight some of the key changes being made and discuss the trade-space in which setting standards must be made to be both useful and broadly adopted.

  17. Behavior changes after minor emergency procedures.

    Science.gov (United States)

    Brodzinski, Holly; Iyer, Srikant

    2013-10-01

    Procedures are common in pediatric emergency departments and frequently cause distress from pain and/or anxiety. The objective of this study was to describe the incidence, types, and magnitude of long-term behavior changes after procedures in the emergency setting. This is a descriptive pilot study to determine if children display negative behavioral changes after a minor emergency department procedure (abscess drainage or laceration repair). Behavior change was measured at 1 week by telephone follow-up using the 27-item Post Hospitalization Behavior Questionnaire, a well-validated instrument that measures behavior changes across 6 categories: general anxiety, separation anxiety, anxiety about sleep, eating disturbances, aggression toward authority, and apathy/withdrawal. Significant behavior change was defined as 5 or more negative behavior changes on the 27-item questionnaire. Twenty percent of children who underwent abscess drainage (n = 30) and 20% who underwent laceration repair (n = 30) displayed significant negative behavior change at 1 week. Children who displayed significant negative behavior change tended to be younger (3.6 vs 5.9 years) and trended toward being more likely to have received anxiolysis or sedation (16.7% vs 8.3%). Separation anxiety, sleep difficulties, and aggression toward authority were the most common behavior changes. In this pilot study, a significant percentage of children undergoing common emergency procedures exhibited an appreciable burden of negative behavior change at 1 week; these results demonstrate the need for further rigorous investigation of predictors of these changes and interventions, which can ameliorate these changes.

  18. Standard Operating Procedure (SOP) for Rapid and Efficient Production of Stevia Tissue Culture Seedlings

    International Nuclear Information System (INIS)

    Norazlina Noordin; Peng, C.S.; Rusli Ibrahim

    2015-01-01

    Stevia rebaudiana Bertoni is a non-caloric natural sweetener which is 300 times sweeter than cane sugar. Extracts from stevia leaves has vast application in food and beverages based industries, can be added to tea and coffee, cooked or baked goods, processed foods and confectionary goods. Recently, stevia attained awareness owing to its natural, non-caloric sweetness by diet/ health conscious and diabetic persons (Arpita et al., 2011). This natural sweetener has high commercial value in global market, it was estimated that global market value for stevia is be around USD11 billion by year 2015. Although stevia is being largely popularized in Malaysia and other countries but large-scale propagation procedures for the continuous supply of planting materials in commercial plantation has yet to be established, optimized and standardized. Furthermore, propagation through stevia seeds is often very difficult due to self-incompatibility which results in sterile seeds (Sakaguchi et al., 1982). Tissue culture is the only rapid process for the mass propagation of stevia and there have been few reports of in vitro growth of stevia (Miyagaya et al., 1986) and in vitro micropropagation from shoot tip and leaf (Uddin et al., 2006). Hence, study was carried out to establish a suitable protocol for in vitro propagation of S. rebaudiana Bertoni that can be further up-scaled for mass propagation of stevia seedlings. The established Standard Operating Procedure (SOP) will ensure rapid and efficient production of stevia tissue culture seedlings for continuous supply of planting materials for commercial stevia plantations in Malaysia. Preparation of growth medium, multiplication of shoots, rooting of plant lets and hardening of ex-vitro rooted plant lets is discussed in this paper. (author)

  19. Comparison of Test Procedures and Energy Efficiency Criteria in Selected International Standards & Labeling Programs for Copy Machines, External Power Supplies, LED Displays, Residential Gas Cooktops and Televisions

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Nina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Zhou, Nan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fridley, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-03-01

    This report presents a technical review of international minimum energy performance standards (MEPS), voluntary and mandatory energy efficiency labels and test procedures for five products being considered for new or revised MEPS in China: copy machines, external power supply, LED displays, residential gas cooktops and flat-screen televisions. For each product, an overview of the scope of existing international standards and labeling programs, energy values and energy performance metrics and description and detailed summary table of criteria and procedures in major test standards are presented.

  20. Extended device profiles and testing procedures for the approval process of integrated medical devices using the IEEE 11073 communication standard.

    Science.gov (United States)

    Janß, Armin; Thorn, Johannes; Schmitz, Malte; Mildner, Alexander; Dell'Anna-Pudlik, Jasmin; Leucker, Martin; Radermacher, Klaus

    2018-02-23

    Nowadays, only closed and proprietary integrated operating room systems (IORS) from big manufacturers are available on the market. Hence, the interconnection of components from third-party vendors is only possible with increased time and costs. In the context of the German Federal Ministry of Education and Research (BMBF)-funded project OR.NET (2012-2016), the open integration of medical devices from different manufacturers was addressed. An integrated operating theater based on the open communication standard IEEE 11073 shall give clinical operators the opportunity to choose medical devices independently of the manufacturer. This approach would be advantageous especially for hospital operators and small- and medium-sized enterprises (SME) of medical devices. Actual standards and concepts regarding technical feasibility and the approval process do not cope with the requirements for a modular integration of medical devices in the operating room (OR), based on an open communication standard. Therefore, innovative approval strategies and corresponding certification and test procedures, which cover actual legal and normative standards, have to be developed in order to support the future risk management and the usability engineering process of open integrated medical devices in the OR. The use of standardized device and service profiles and a three-step testing procedure, including conformity, interoperability and integration tests are described in this paper and shall support the manufacturers to integrate their medical devices without disclosing the medical devices' risk analysis and related confidential expertise or proprietary information.

  1. The use of faces as stimuli in neuroimaging and psychological experiments: a procedure to standardize stimulus features.

    Science.gov (United States)

    Gronenschild, Ed H B M; Smeets, Floortje; Vuurman, Eric F P M; van Boxtel, Martin P J; Jolles, Jelle

    2009-11-01

    In psychological experiments involving facial stimuli, it is of great importance that the basic perceptual or psychological characteristics that are investigated are not confounded by factors such as brightness and contrast, head size, hair cut and color, skin color, and the presence of glasses and earrings. Standardization of facial stimulus materials reduces the effect of these confounding factors. We therefore employed a set of basic image processing techniques to deal with this issue. The processed images depict the faces in grayscale, all at the same size, brightness, and contrast, and confined to an oval mask revealing only the basic features such as the eyes, nose, and mouth. The standardization was successfully applied to four different face databases, consisting of male and female faces and including neutral as well as happy facial expressions. An important advantage of the proposed standardization is that featural as well as configurational information is retained. We also consider the procedure to be a major contribution to the development of a de facto standard for the use of facial stimuli in psychological experiments. Such methodological standardization would allow a better comparison of the results of these studies.

  2. Sphincter-saving procedure for radiation-injuried rectum

    International Nuclear Information System (INIS)

    Moriya, Yoshihiro; Koyama, Yasuo; Hojo, Keiichi

    1982-01-01

    Up to this time the sigmoid colostomy has been widely accepted and conventional treatment for radiation-injured rectum, but patients without residual malignancy strongly desire to live without colostomy. We have tried to remove the involved rectal segments by sphincter-saving procedures. Four patients underwent these procedures, pull-through procedure in three and low anterior resection in one. Among sphincter-saving procedures, pull-through procedure was most adequate. Provided the following five conditions are fulfilled, pull-through procedure should be considered for severe radiation-injured rectum. (1) No recurrence of initial malignancy in the pelvis. (2) More than 2 cm intact rectal segment above dentate line may be preserved. (3) No radiation-injured segment in upper sigmoid. (4) No severe radiation damage in small intestine. (5) Patients under 70 year-old, with normal tonus of anal sphincter. (author)

  3. Standard colonic lavage alters the natural state of mucosal-associated microbiota in the human colon.

    Directory of Open Access Journals (Sweden)

    Laura Harrell

    Full Text Available Past studies of the human intestinal microbiota are potentially confounded by the common practice of using bowel-cleansing preparations. We examined if colonic lavage changes the natural state of enteric mucosal-adherent microbes in healthy human subjects.Twelve healthy individuals were divided into three groups; experimental group, control group one, and control group two. Subjects in the experimental group underwent an un-prepped flexible sigmoidoscopy with biopsies. Within two weeks, subjects were given a standard polyethylene glycol-based bowel cleansing preparation followed by a second flexible sigmoidoscopy. Subjects in control group one underwent two un-prepped flexible sigmoidoscopies within one week. Subjects in the second control group underwent an un-prepped flexible sigmoidoscopy followed by a second flexible sigmoidoscopy after a 24-hour clear liquid diet within one week. The mucosa-associated microbial communities from the two procedures in each subject were compared using 16S rRNA gene based terminal restriction fragment length polymorphism (T-RFLP, and library cloning and sequencing.Clone library sequencing analysis showed that there were changes in the composition of the mucosa-associated microbiota in subjects after colonic lavage. These changes were not observed in our control groups. Standard bowel preparation altered the diversity of mucosa-associated microbiota. Taxonomic classification did not reveal significant changes at the phylum level, but there were differences observed at the genus level.Standard bowel cleansing preparation altered the mucosal-adherent microbiota in all of our subjects, although the degree of change was variable. These findings underscore the importance of considering the confounding effects of bowel preparation when designing experiments exploring the gut microbiota.

  4. Reversal of Hartmann's procedure following acute diverticulitis: is timing everything?

    LENUS (Irish Health Repository)

    Fleming, Fergal J

    2012-02-01

    BACKGROUND: Patients who undergo a Hartmann\\'s procedure may not be offered a reversal due to concerns over the morbidity of the second procedure. The aims of this study were to examine the morbidity post reversal of Hartmann\\'s procedure. METHODS: Patients who underwent a Hartmann\\'s procedure for acute diverticulitis (Hinchey 3 or 4) between 1995 and 2006 were studied. Clinical factors including patient comorbidities were analysed to elucidate what preoperative factors were associated with complications following reversal of Hartmann\\'s procedure. RESULTS: One hundred and ten patients were included. Median age was 70 years and 56% of the cohort were male (n = 61). The mortality and morbidity rate for the acute presentation was 7.3% (n = 8) and 34% (n = 37) respectively. Seventy six patients (69%) underwent a reversal at a median of 7 months (range 3-22 months) post-Hartmann\\'s procedure. The complication rate in the reversal group was 25% (n = 18). A history of current smoking (p = 0.004), increasing time to reversal (p = 0.04) and low preoperative albumin (p = 0.003) were all associated with complications following reversal. CONCLUSIONS: Reversal of Hartmann\\'s procedure can be offered to appropriately selected patients though with a significant (25%) morbidity rate. The identification of potential modifiable factors such as current smoking, prolonged time to reversal and low preoperative albumin may allow optimisation of such patients preoperatively.

  5. Sphincter-saving procedure for radiation-injuried rectum. A report of four cases with special reference to pull-through procedure

    Energy Technology Data Exchange (ETDEWEB)

    Moriya, Y.; Koyama, Y.; Hojo, K. (National Cancer Center, Tokyo (Japan))

    1982-09-01

    Up to this time the sigmoid colostomy has been widely accepted and conventional treatment for radiation-injured rectum, but patients without residual malignancy strongly desire to live without colostomy. We have tried to remove the involved rectal segments by sphincter-saving procedures. Four patients underwent these procedures, pull-through procedure in three and low anterior resection in one. Among sphincter-saving procedures, pull-through procedure was most adequate. Provided the following five conditions are fulfilled, pull-through procedure should be considered for severe radiation-injured rectum. (1) No recurrence of initial malignancy in the pelvis. (2) More than 2 cm intact rectal segment above dentate line may be preserved. (3) No radiation-injured segment in upper sigmoid. (4) No severe radiation damage in small intestine. (5) Patients under 70 year-old, with normal tonus of anal sphincter.

  6. Unanticipated hospital admission in pediatric patients with congenital heart disease undergoing ambulatory noncardiac surgical procedures.

    Science.gov (United States)

    Yuki, Koichi; Koutsogiannaki, Sophia; Lee, Sandra; DiNardo, James A

    2018-05-18

    An increasing number of surgical and nonsurgical procedures are being performed on an ambulatory basis in children. Analysis of a large group of pediatric patients with congenital heart disease undergoing ambulatory procedures has not been undertaken. The objective of this study was to characterize the profile of children with congenital heart disease who underwent noncardiac procedures on an ambulatory basis at our institution, to determine the incidence of adverse cardiovascular and respiratory adverse events, and to determine the risk factors for unscheduled hospital admission. This is a retrospective study of children with congenital heart disease who underwent noncardiac procedures on an ambulatory basis in a single center. Using the electronic preoperative anesthesia evaluation form, we identified 3010 patients with congenital heart disease who underwent noncardiac procedures of which 1028 (34.1%) were scheduled to occur on an ambulatory basis. Demographic, echocardiographic and functional status data, cardiovascular and respiratory adverse events, and reasons for postprocedure admission were recorded. Univariable analysis was conducted. The unplanned hospital admission was 2.7% and univariable analysis demonstrated that performance of an echocardiogram within 6 mo of the procedure and procedures performed in radiology were associated with postoperative admission. Cardiovascular adverse event incidence was 3.9%. Respiratory adverse event incidence was 1.8%. Ambulatory, noncomplex procedures can be performed in pediatric patients with congenital heart disease and good functional status with a relatively low unanticipated hospital admission rate. © 2018 John Wiley & Sons Ltd.

  7. Pancreaticoduodenectomy for pancreatic head cancer: PPPD versus Whipple procedure.

    Science.gov (United States)

    Lin, Pin-Wen; Shan, Yan-Shen; Lin, Yih-Jyh; Hung, Chung-Jye

    2005-01-01

    Resectable carcinoma of the head of the pancreas can be treated with either standard (the Whipple) or pylorus-preserving pancreaticoduodenectomy (PPPD). Only a few reports compared the differences between these two procedures. From July 1994 to Oct 2002, a prospective randomized comparison between the Whipple procedure and PPPD done by the same surgeon for the patients with carcinoma of the head of the pancreas was conducted. Thirty-six patients diagnosed as pancreatic head adenocarcinoma were randomized to receive either the Whipple procedure or a PPPD. Three patients initially randomized to have a PPPD were converted to the Whipple procedure due to gross duodenal involvement. Finally, 19 patients received the Whipple procedure, 14 patients underwent PPPD and three patients had conversion. Two perioperative deaths in the Whipple group and one perioperative death in PPPD resulted in an 8 percent mortality rate in the 36 patients. Median duration of the Whipple operation was 265 (range 203-475) min with a median blood loss of 570 (50-8540) mL. In the patients who had PPPD, median operating time was 232 (range 165-270) min, and median blood loss was 375 (range 100-1300) mL. There was one minor leak from the pancreaticojejunostomy in each group, resulting in a 5.5 percent minor leak in 36 patients. These outcomes were not significantly different. Delayed gastric emptying was observed more frequently after PPPD (six of 14 patients) than after the Whipple procedure (none of 19 patients) (P Whipple procedure and PPPD in terms of median survival and 5-year survival rate. The median survival time was 16.0 months and 5-year survival rate was 9.4 percent in the 36 patients. Blood loss during operation influenced the prognosis. There was no significant difference between the Whipple procedure and PPPD for the treatment of pancreatic head cancer in terms of operating time, blood loss, operative mortality and long-term survival. But delayed gastric emptying was more frequently

  8. Electrocoagulative Surgical Procedure for Treatment of Conjunctivochalasis

    Science.gov (United States)

    Zhang, Xing-Ru; Zhang, Zhen-Yong; Hoffman, Matthew R.

    2012-01-01

    The purpose of this study was to present a new procedure to treat symptomatic conjunctivochalasis (CCh) and to evaluate its efficacy. Forty-two patients with symptomatic CCh refractory to medical management were included on this study. Twenty-two patients (n  =  32, eyes; n  =  14 women and n  =  8 men) underwent the new electrocoagulation procedure (Group I). Twenty patients (n  =  27 eyes; n  =  11 women and n  =  9 men) underwent crescent-shaped conjunctiva resection (Group II). Ocular Surface Disease Index (OSDI) was used to evaluate ocular symptoms. There was a significant difference in mean and SD operation time between Group I (8.67 ± 2.07 minutes) and Group II (20.45 ± 3.98 minutes; P Electrocoagulation of the conjunctiva can successfully treat symptomatic CCh with earlier symptomatic attenuation and less operation time than traditional conjunctiva resection. PMID:23102005

  9. Emergency Kausch-Whipple procedure: indications and experiences.

    Science.gov (United States)

    Standop, Jens; Glowka, Tim; Schmitz, Volker; Schaefer, Nico; Hirner, Andreas; Kalff, Jörg C

    2010-03-01

    Pancreaticoduodenectomy is a demanding procedure even in selected patients but becomes formidable when performed in cases of emergency. This study analyzed our experience with urgent pancreatoduodenectomies; special emphases were put on the evaluation of diagnostic means and the validation of existing indications for performance of this procedure. Three hundred one patients who underwent pancreatoduodenectomy between 1989 and 2008 were identified from a pancreatic resection database and reviewed for emergency indications. Six patients (2%) underwent emergency pancreatoduodenectomy. Indications included endoscopy-related perforation, postoperative complications, and uncontrollable intraduodenal tumor bleeding. Length of stay and occurrence of nonsurgical complications were increased in emergency compared with elective pancreatoduodenectomies. Although increased, no significant differences were found regarding mortality and surgery-related complications. Indications for emergency pancreatoduodenectomies were based on clinical decisions rather than on radiologic diagnostics. Urgent pancreatic head resections may be considered as an option in selected patients if handling of local complications by interventional measures or limited surgery seems unsafe.

  10. A Guide for Developing Standard Operating Job Procedures for the Screening & Grinding Process Wastewater Treatment Facility. SOJP No. 1.

    Science.gov (United States)

    Deal, Gerald A.; Montgomery, James A.

    This guide describes standard operating job procedures for the screening and grinding process of wastewater treatment facilities. The objective of this process is the removal of coarse materials from the raw waste stream for the protection of subsequent equipment and processes. The guide gives step-by-step instructions for safety inspection,…

  11. The 'Whip-Stow' procedure: an innovative modification to the whipple procedure in the management of premalignant and malignant pancreatic head disease.

    Science.gov (United States)

    Jeyarajah, D Rohan; Khithani, Amit; Curtis, David; Galanopoulos, Christos A

    2010-01-01

    Pancreaticoduodenectomy (PD) is the standard of care in the treatment of premalignant and malignant diseases of the head of the pancreas. Variability exists in anastomosis with the pancreatic remnant. This work describes a safe and easy modification for the pancreatic anastomosis after PD. Ten patients underwent the "Whip-Stow" procedure for the management of the pancreatic remnant. PD combined with a Puestow (lateral pancreaticojejunostomy [LPJ]) was completed using a running single-layer, 4-0 Prolene obeying a duct-to-mucosa technique. LPJ and pancreaticogastrostomy (PG) historical leak rates are reported to be 13.9 and 15.8 per cent, respectively. Mortality, leak, and postoperative bleeding rates were 0 per cent in all patients. The Whip-Stow was completed without loops or microscope with a 4-0 single-layer suture decreasing the time and complexity of the anastomosis. Average time was 12 minutes as compared with the 50 minutes of a 5 or 6-0 interrupted, multilayered duct-mucosa anastomosis. Benefits included a long-segment LPJ. In this study, the Whip-Stow procedure has proven to be a safe and simple approach to pancreatic anastomosis in selected patients. This new technique provides the benefit of technical ease while obeying the age old principles of obtaining a wide duct to mucosa anastomosis.

  12. Manual of Standard Operating Procedures for Veterinary Drug Residue Analysis

    International Nuclear Information System (INIS)

    2016-01-01

    Laboratories are crucial to national veterinary drug residue monitoring programmes. However, one of the main challenges laboratories encounter is obtaining access to relevant methods of analysis. Thus, in addition to training, providing technical advice and transferring technology, the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture has resolved to develop clear and practical manuals to support Member State laboratories. The Coordinated Research Project (CRP) on Development of Radiometric and Allied Analytical Methods to Strengthen Residue Control Programs for Antibiotic and Anthelmintic Veterinary Drug Residues has developed a number of analytical methods as standard operating procedures (SOPs), which are now compiled here. This publication contains SOPs on chromatographic and spectrometric techniques, as well as radioimmunoassay and associated screening techniques, for various anthelmintic and antimicrobial veterinary drug residue analysis. Some analytical method validation protocols are also included. The publication is primarily aimed at food and environmental safety laboratories involved in testing veterinary drug residues, including under organized national residue monitoring programmes. It is expected to enhance laboratory capacity building and competence through the use of radiometric and complementary tools and techniques. The publication is also relevant for applied research on residues of veterinary drugs in food and environmental samples

  13. Discharge communication from inpatient care: an audit of written medical discharge summary procedure against the new National Health Service Standard for clinical handover.

    Science.gov (United States)

    Reid, Daniel Brooks; Parsons, Shaun R; Gill, Stephen D; Hughes, Andrew J

    2015-04-01

    To audit written medical discharge summary procedure and practice against Standard Six (clinical handover) of the Australian National Safety and Quality Health Service Standards at a major regional Victorian health service. Department heads were invited to complete a questionnaire about departmental discharge summary practices. Twenty-seven (82%) department heads completed the questionnaire. Seven (26%) departments had a documented discharge summary procedure. Fourteen (52%) departments monitored discharge summary completion and 13 (48%) departments monitored the timeliness of completion. Seven (26%) departments informed the patient of the content of the discharge summary and six (22%) departments provided the patient with a copy. Seven (26%) departments provided training for staff members on how to complete discharge summaries. Completing discharge summaries was usually delegated to the medical intern. The introduction of the National Service Standards prompted an organisation-wide audit of discharge summary practices against the external criterion. There was substantial variation in the organisation's practices. The Standards and the current audit results highlight an opportunity for the organisation to enhance and standardise discharge summary practices and improve communication with general practice.

  14. Risk factors for postoperative urinary tract infection following midurethral sling procedures.

    Science.gov (United States)

    Doganay, Melike; Cavkaytar, Sabri; Kokanali, Mahmut Kuntay; Ozer, Irfan; Aksakal, Orhan Seyfi; Erkaya, Salim

    2017-04-01

    To identify the potential risk factors for urinary tract infections following midurethral sling procedures. 556 women who underwent midurethral sling procedure due to stress urinary incontinence over a four-year period were reviewed in this retrospective study. Of the study population, 280 women underwent TVT procedures and 276 women underwent TOT procedures. Patients were evaluated at 4-8 weeks postoperatively and were investigated for the occurrence of a urinary tract infection. Patients who experienced urinary tract infection were defined as cases, and patients who didn't were defined as controls. All data were collected from medical records. Multivariate logistic regression model was used to identify the risk factors for urinary tract infection. Of 556 women, 58 (10.4%) were defined as cases while 498 (89.6%) were controls. The mean age of women in cases (57.8±12.9years) was significantly greater than in controls (51.8±11.2years) (purinary tract infection, concomitant vaginal hysterectomy and cystocele repair, TVT procedure and postoperative postvoiding residual bladder volume ≥100ml were more common in cases than in controls. However, in multivariate regression analysis model presence of preoperative urinary tract infection [OR (95% CI)=0.1 (0.1-0.7); p=0.013], TVT procedure [OR (95% CI)=8.4 (3.1-22.3); p=0.000] and postoperative postvoiding residual bladder volume ≥100ml [OR (95% CI)=4.6 (1.1-19.2); p=0.036] were significant independent risk factors for urinary tract infection following midurethral slings CONCLUSION: Urinary tract infection after midurethral sling procedures is a relatively common complication. The presence of preoperative urinary tract infection, TVT procedure and postoperative postvoiding residual bladder volume ≥100ml may increase the risk of this complication. Identification of these factors could help surgeons to minimize this complicationby developing effective strategies. Copyright © 2017. Published by Elsevier B.V.

  15. A Randomized Controlled Trial to Compare e-Feedback Versus "Standard" Face-to-Face Verbal Feedback to Improve the Acquisition of Procedural Skill.

    Science.gov (United States)

    Al-Jundi, Wissam; Elsharif, Mohamed; Anderson, Melanie; Chan, Phillip; Beard, Jonathan; Nawaz, Shah

    Constructive feedback plays an important role in learning during surgical training. Standard feedback is usually given verbally following direct observation of the procedure by a trained assessor. However, such feedback requires the physical presence of expert faculty members who are usually busy and time-constrained by clinical commitments. We aim to evaluate electronic feedback (e-feedback) after video observation of surgical suturing in comparison with standard face-to-face verbal feedback. A prospective, blinded, randomized controlled trial comparing e-feedback with standard verbal feedback was carried out in February 2015 using a validated pro formas for assessment. The study participants were 38 undergraduate medical students from the University of Sheffield, UK. They were recorded on video performing the procedural skill, completed a self-evaluation form, and received e-feedback on the same day (group 1); observed directly by an assessor, invited to provide verbal self-reflection, and then received standard verbal feedback (group 2). In both groups, the feedback was provided after performing the procedure. The participants returned 2 days later and performed the same skill again. Poststudy questionnaire was used to assess the acceptability of each feedback among the participants. Overall, 19 students in group 1 and 18 students in group 2 completed the study. Although there was a significant improvement in the overall mean score on the second performance of the task for all participants (first performance mean 11.59, second performance mean 15.95; p ≤ 0.0001), there was no difference in the overall mean improvement score between group 1 and group 2 (4.74 and 3.94, respectively; p = 0.49). The mean overall scores for the e-feedback group at baseline recorded by 2 independent investigators showed good agreement (mean overall scores of 12.84 and 11.89; Cronbach α = 0.86). Poststudy questionnaire demonstrated that both e-feedback and standard verbal feedback

  16. Seminar on standards, standardization, quality control and interlaboratory test programmes

    Energy Technology Data Exchange (ETDEWEB)

    de Bievre, P. [Central Bureau for Nuclear Measurements, Geel (Belgium)

    1978-12-15

    The author gives a resume on the proper use of standards and standardization of measurement procedures. Results of measurements obtained on the same instrument and on the same series of standards of different isotopic compositions are displayed.

  17. 40 CFR 761.79 - Decontamination standards and procedures.

    Science.gov (United States)

    2010-07-01

    .... (b) Decontamination standards. Chopping (including wire chopping), distilling, filtering, oil/water... burned and marketed in accordance with the requirements for used oil in § 761.20(e), disposed of in... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Decontamination standards and...

  18. Patient controlled sedation using a standard protocol for dressing changes in burns: patients' preference, procedural details and a preliminary safety evaluation.

    Science.gov (United States)

    Nilsson, Andreas; Steinvall, Ingrid; Bak, Zoltan; Sjöberg, Folke

    2008-11-01

    Patient controlled sedation (PCS) enables patients to titrate doses of drugs by themselves during different procedures involving pain or discomfort. We studied it in a prospective crossover design using a fixed protocol without lockout time to examine it as an alternative method of sedation for changing dressings in burned patients. Eleven patients with >10% total burn surface area (TBSA) had their dressings changed, starting with sedation by an anaesthetist (ACS). The second dressing change was done with PCS (propofol/alfentanil) and the third time the patients had to choose ACS or PCS. During the procedures, data on cardiopulmonary variables, sedation (bispectral index), pain intensity (VAS), procedural details, doses of drugs, and patients' preferences were collected to compare the two sedation techniques. The study data indicated that wound care in burned patients is feasible with a standardized PCS protocol. The patients preferred PCS to ACS on the basis of self-control, and because they had less discomfort during the recovery period. Wound care was also considered adequate by the staff during PCS. No respiratory (respiratory rate/transcutaneous PCO(2)) or cardiovascular (heart rate/blood pressure) adverse events were recorded at any time during any of the PCS procedures. The doses of propofol and alfentanil and BIS index decrease were less during PCS than ACS. Procedural pain was higher during PCS but lower after the procedure. We suggest that PCS using a standard protocol is an interesting alternative to anaesthetist-provided sedation during dressing changes. It seems effective, saves resources, is safe, and at same time is preferred by the patients. The strength of these conclusions is, however, hampered by the small size of this investigation and therefore further studies are warranted.

  19. The Ross Procedure in Pediatric Patients: A 20-Year Experience of Ross Procedure in a Single Institution.

    Science.gov (United States)

    Yoon, Dong Woog; Yang, Ji-Hyuk; Jun, Tae-Gook; Park, Pyo Won

    2017-08-01

    The Ross/Ross-Konno procedure is considered a good option for irreparable aortic valve disease in pediatric patients because of its hemodynamic performance and potential for growth of the pulmonary autograft. This study is a review of the long-term results of our 20-year experience with the Ross and Ross-Konno operations in a single institution. Between June 1995 and January 2016, 16 consecutive patients (mean age, 6.0±5.9 years; range, 16 days to 17.4 years) underwent either a Ross operation (n=9) or a Ross-Konno operation (n=7). The study included 12 males and 4 females, with a median follow-up period of 47 months (range, 6 to 256 months). There were no cases of in-hospital or late mortality. Six reoperations were performed in 5 patients. Four patients underwent right ventricular-pulmonary artery (RV-PA) conduit replacement. Two patients underwent concomitant replacement of the pulmonary autograft and RV-PA conduit 10 years and 8 years after the Ross operation, respectively. The rate of freedom from adverse outcomes of the pulmonary autograft was 88% and 70% at 5 and 10 years, respectively. The rate of freedom from valve-related reoperations was 79% and 63% at 5 and 10 years, respectively. Pulmonary autografts demonstrated good durability with low mortality. The Ross/Ross-Konno procedure is a good option that can be performed safely in pediatric patients with aortic valve disease, even in a small-volume center.

  20. Standard Operating Procedure for the Grinding and Extraction of Lead in Paint using Nitric Acid and a Rotor/Stator System Powered by a High Speed Motor

    Science.gov (United States)

    This Standard Operating Procedure (SOP) describes a new, rapid, and relatively inexpensive one step procedure which grinds the paint samples removed from the substrate and simultaneously quantitatively extracts the Pb from the paint in only one step in preparation for quantitativ...

  1. AN ANALYTICAL STUDY OF EFFICACY OF CORNEAL COLLAGEN CROSSLINKING C3R PROCEDURE IN PROGRESSIVE KERATOCONUS PATIENTS

    Directory of Open Access Journals (Sweden)

    Rajasekar K

    2017-10-01

    Full Text Available BACKGROUND Keratoconus affects a significant number of the general population with conical weakened protruded area from the cornea due to weakening of the corneal stroma by a genetically premeditated preponderance. We see keratoconus as a standalone disease or accompanying other syndrome manifestations in patients. Mainly, the inferotemporal cornea is affected and the conical protrusion causes profound high irregular myopic astigmatism as a refractive error, which is very difficult to correct in progressed advanced stages. Especially in economically productive age group patients, the poor vision becomes very difficult to live with. Corneal collagen crosslinking procedure is a novel tool in the armamentarium of treatment procedures against this malady. MATERIALS AND METHODS This analytical study was conducted at cornea services, Regional Institute of Ophthalmology and Government Ophthalmic Hospital, Chennai, for a period of 14 months. Forty five eyes of forty patients with early progressive keratoconus who presented to cornea services were subjected to riboflavin UVA collagen crosslinking procedures using a standard protocol after getting an informed consent. Further response to treatment were assessed in the follow up period. RESULTS Out of 40 patients in our series, 23 were males and 17 were females. The maximum patients in our series were in the age group between 10 to 25 yrs. Epi-off procedure was done in 31 eyes and epi-on procedure was done in 14 eyes. The patients with pachymetry 400-450 microns underwent epi-on procedure and more than 450 microns underwent epi-off C3R procedure. The K values in our series were between 49D to maximum 63D. The topographic flattening was seen in 52% in epi-on and epi-off procedures. Vision improvement in our series was 57% following epi-on and 65% following epi-off procedures. CONCLUSION C3R is a very promising therapeutic modality that may halt the progression of ectatic process. It is a less invasive mode

  2. Large regional differences in incidence of arthroscopic meniscal procedures in the public and private sector in Denmark

    DEFF Research Database (Denmark)

    Hare, Kristoffer Borbjerg; Vinther, Jesper Høeg; Lohmander, L Stefan

    2015-01-01

    OBJECTIVES: A recent study reported a large increase in the number of meniscal procedures from 2000 to 2011 in Denmark. We examined the nation-wide distribution of meniscal procedures performed in the private and public sector in Denmark since different incentives may be present and the use...... of these procedures may differ from region to region. SETTING: We included data on all patients who underwent an arthroscopic meniscal procedure performed in the public or private sector in Denmark. PARTICIPANTS: Data were retrieved from the Danish National Patient Register on patients who underwent arthroscopic...... for public and private procedures for each region. RESULTS: Incidence of meniscal procedures increased at private and at public hospitals. The private sector accounted for the largest relative and absolute increase, rising from an incidence of 1 in 2000 to 98 in 2011. In 2011, the incidence of meniscal...

  3. Elaboration and implementation of standard operational procedure for quality assurance of cone beam CT image in radiotherapy

    International Nuclear Information System (INIS)

    Bonatto, Larisse N.; Estacio, Daniela R.; Lopes, Juliane S.; Sansson, Angela; Duarte, Lucas O.; Sbaraini, Patricia; Silva, Ana M. Marques da; Streck, Elaine E.

    2016-01-01

    The objective of this article is to present the implementation of the quality Control of Cone Beam Computed Tomography (CBCT) image, generated by the On-Board Imager, integrated with the linear accelerator Trilogy. Standard operating procedures (POPs) have been developed based on the literature and manuals of the simulator object Catphan 504 and the On-Board Imager. The following POPs were developed: acquisition of the CBCT image; linearity of CT number; uniformity; spatial resolution; low contrast resolution; spatial linearity; thickness of the cut. The validation of the elaborated procedures was done from an experimental acquisition of the simulator object. The results obtained in the validation of the POPs are in compliance with the parameters established by the manufacturer of the simulator object, as well as those obtained in the acceptance of the On-Board Imager device.

  4. Pediatric abdominal non-Hodgkin's lymphoma: diagnosis through surgical and non-surgical procedures.

    Science.gov (United States)

    Aguiar, Arthur Almeida; Lima, Luciana Cavalvanti; Araújo, Cláudia Corrêa de; Gallindo, Rodrigo Melo

    2017-12-29

    To describe the success rate and the complications after procedures to diagnose abdominal non-Hodgkin's lymphoma in children and adolescents. A retrospective cross-sectional study was conducted with a population consisting of children and adolescents with abdominal non-Hodgkin's lymphoma diagnosed between September 1994 and December 2012. The sample comprised of 100 patients who underwent 113 diagnostic procedures, including urgent surgery (n=21), elective surgery (n=36), and non-surgical diagnosis (n=56). The most frequent procedures were laparotomy (46.9%) and ultrasound-guided core biopsy (25.6%). The rate of diagnostic success was 95.2% for urgent surgeries; 100% for elective surgeries and 82.1% for non-surgical procedures (p<0.05). The rates of complication during the three diagnosis procedures considered were significant (p<0.001; 95.2% of the urgent surgeries, 83.8% of the elective surgeries, and 10.7% of the non-surgical procedures). The length of time before resuming a full diet and starting chemotherapy was significantly reduced for patients who underwent non-surgical procedures when compared with the other procedures (p<0.001). Non-surgical procedures for the diagnosis of pediatric abdominal non-Hodgkin's lymphoma are an effective option with low morbidity rate, allowing an earlier resumption of a full diet and chemotherapy initiation. Furthermore, non-surgical procedures should also be considered for obtaining tumor samples from patients with extensive disease. Copyright © 2017. Published by Elsevier Editora Ltda.

  5. On anti-earthquake design procedure of equipment and pipings in near future

    International Nuclear Information System (INIS)

    Shibata, H.

    1981-01-01

    The requirement of anti-earthquake design of nuclear power plants is getting severe year by year. The author will try to discuss how to control its severity and how to find a proper design procedure for licensing of new plants under such severe requirements. On the other hand we suffered from the enormous volumes of documents. To decrease such volumes, the format of documents should be standardized as well as the design procedure standardization. Starting from this point, we need the research and development on the following subjects: i) Standardization of design procedure. ii) Standardization of document. iii) Establishment of standard review procedure using computer. iv) Standardization of earthquake-resistant designed equipment. v) Standardization of anti-earthquake design procedure of piping systems. vi) Introducing margin evaluation procedure to design procedure. vii) Introducing proving test procedure of active component to design procedure. viii) Establishment of evaluation of human reliability in design, fabrication, inspection procedures. ix) Establishment of the proper relation of seismic trigger level and post-earthquake design procedures. (orig./HP)

  6. Influence of new customs procedures and logistic security standards on companies competiveness – a Croatian company case study

    OpenAIRE

    Erceg, Aleksandar

    2014-01-01

    In today’s global market, companies are constantly confronted with the competition on the local, national and international level. Companies therefore use a variety of strategies and tools to become and/or remain competitive. Potential areas for cost reduction in companies are supply chain management and logistic and customs procedures. Implementation of various logistic standards in supply chain management can provide significant cost savings for the company’s daily operations an...

  7. Reliability and Validity of 10 Different Standard Setting Procedures.

    Science.gov (United States)

    Halpin, Glennelle; Halpin, Gerald

    Research indicating that different cut-off points result from the use of different standard-setting techniques leaves decision makers with a disturbing dilemma: Which standard-setting method is best? This investigation of the reliability and validity of 10 different standard-setting approaches was designed to provide information that might help…

  8. Use of Bone Scan During Initial Prostate Cancer Workup, Downstream Procedures, and Associated Medicare Costs

    Energy Technology Data Exchange (ETDEWEB)

    Falchook, Aaron D. [Department of Radiation Oncology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Salloum, Ramzi G. [Department of Health Services Policy and Management, University of South Carolina, Columbia, South Carolina (United States); Hendrix, Laura H. [Department of Radiation Oncology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Chen, Ronald C., E-mail: ronald_chen@med.unc.edu [Department of Radiation Oncology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Cecil G. Sheps Center for Health Services Research, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States); Lineberger Comprehensive Cancer Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina (United States)

    2014-06-01

    Purpose: For patients with a high likelihood of having metastatic disease (high-risk prostate cancer), bone scan is the standard, guideline-recommended test to look for bony metastasis. We quantified the use of bone scans and downstream procedures, along with associated costs, in patients with high-risk prostate cancer, and their use in low- and intermediate-risk patients for whom these tests are not recommended. Methods and Materials: Patients in the Surveillance, Epidemiology, and End Results (SEER)-Medicare database diagnosed with prostate cancer from 2004 to 2007 were included. Prostate specific antigen (PSA), Gleason score, and clinical T stage were used to define D'Amico risk categories. We report use of bone scans from the date of diagnosis to the earlier of treatment or 6 months. In patients who underwent bone scans, we report use of bone-specific x-ray, computed tomography (CT), and magnetic resonance imaging (MRI) scans, and bone biopsy within 3 months after bone scan. Costs were estimated using 2012 Medicare reimbursement rates. Results: In all, 31% and 48% of patients with apparent low- and intermediate-risk prostate cancer underwent a bone scan; of these patients, 21% underwent subsequent x-rays, 7% CT, and 3% MRI scans. Bone biopsies were uncommon. Overall, <1% of low- and intermediate-risk patients were found to have metastatic disease. The annual estimated Medicare cost for bone scans and downstream procedures was $11,300,000 for low- and intermediate-risk patients. For patients with apparent high-risk disease, only 62% received a bone scan, of whom 14% were found to have metastasis. Conclusions: There is overuse of bone scans in patients with low- and intermediate-risk prostate cancers, which is unlikely to yield clinically actionable information and results in a potential Medicare waste. However, there is underuse of bone scans in high-risk patients for whom metastasis is likely.

  9. Measuring fuel moisture content in Alaska: standard methods and procedures.

    Science.gov (United States)

    Rodney A. Norum; Melanie. Miller

    1984-01-01

    Methods and procedures are given for collecting and processing living and dead plant materials for the purpose of determining their water content. Wild-land fuels in Alaska are emphasized, but the methodology is applicable elsewhere. Guides are given for determining the number of samples needed to attain a chosen precision. Detailed procedures are presented for...

  10. Evaluation of a standardized procedure for [corrected] microscopic cell counts [corrected] in body fluids.

    Science.gov (United States)

    Emerson, Jane F; Emerson, Scott S

    2005-01-01

    A standardized urinalysis and manual microscopic cell counting system was evaluated for its potential to reduce intra- and interoperator variability in urine and cerebrospinal fluid (CSF) cell counts. Replicate aliquots of pooled specimens were submitted blindly to technologists who were instructed to use either the Kova system with the disposable Glasstic slide (Hycor Biomedical, Inc., Garden Grove, CA) or the standard operating procedure of the University of California-Irvine (UCI), which uses plain glass slides for urine sediments and hemacytometers for CSF. The Hycor system provides a mechanical means of obtaining a fixed volume of fluid in which to resuspend the sediment, and fixes the volume of specimen to be microscopically examined by using capillary filling of a chamber containing in-plane counting grids. Ninety aliquots of pooled specimens of each type of body fluid were used to assess the inter- and intraoperator reproducibility of the measurements. The variability of replicate Hycor measurements made on a single specimen by the same or different observers was compared with that predicted by a Poisson distribution. The Hycor methods generally resulted in test statistics that were slightly lower than those obtained with the laboratory standard methods, indicating a trend toward decreasing the effects of various sources of variability. For 15 paired aliquots of each body fluid, tests for systematically higher or lower measurements with the Hycor methods were performed using the Wilcoxon signed-rank test. Also examined was the average difference between the Hycor and current laboratory standard measurements, along with a 95% confidence interval (CI) for the true average difference. Without increasing labor or the requirement for attention to detail, the Hycor method provides slightly better interrater comparisons than the current method used at UCI. Copyright 2005 Wiley-Liss, Inc.

  11. Consultative Committee for Space Data Systems recommendation for space data system standards: Telecommand. Part 2.1: Command operation procedures

    Science.gov (United States)

    1991-01-01

    This recommendation contains the detailed specification of the logic required to carry out the Command Operations Procedures of the Transfer Layer. The Recommendation for Telecommand--Part 2, Data Routing Service contains the standard data structures and data communication procedures used by the intermediate telecommand system layers (the Transfer and Segmentation Layers). In particular, it contains a brief description of the Command Operations Procedures (COP) within the Transfer Layer. This recommendation contains the detailed definition of the COP's in the form of state tables, along with definitions of the terms used. It is assumed that the reader of this document is familiar with the data structures and terminology of part 2. In case of conflict between the description of the COP's in part 2 and in this recommendation, the definition in this recommendation will take precedence. In particular, this document supersedes section 4.3.3.1 through 4.3.3.4 of part 2.

  12. Bio-Oil Analysis Laboratory Procedures | Bioenergy | NREL

    Science.gov (United States)

    Bio-Oil Analysis Laboratory Procedures Bio-Oil Analysis Laboratory Procedures NREL develops laboratory analytical procedures (LAPs) for the analysis of raw and upgraded pyrolysis bio-oils. These standard procedures have been validated and allow for reliable bio-oil analysis. Procedures Determination

  13. Development of a standard operating procedure for mammography equipment used in calibration of ionized chambers

    International Nuclear Information System (INIS)

    Rodrigues, Yklys Santos; Potiens, Maria da Penha Albuquerque

    2011-01-01

    Mammography is one widely used technique in the detection of breast cancer. In order to optimize the results achieving better images with lower dose rates, a quality assurance programme must be applied to the equipment. Some control tests use ionization chambers to measure air kerma and other quantities. These tests can only be reliable if the ionization chambers used on them are correctly calibrated. In the present work, it was developed a standard operating procedure (SOP) for quality control tests in a commercial mammography equipment installed in the Calibration Laboratory (LCI) at IPEN - Brazilian Institute for energy and nuclear research). Seven tests were performed in the equipment: Tube voltage and exposition time accuracy and reproducibility, linearity and reproducibility of Air kerma and Half Value Layer (HVL). Then, it was made a measurement of the air kerma in the mammography equipment, using a reference ionization chamber with traceability to a primary laboratory in Germany (Physikalisch-Technische Bundesanstalt - PTB), that was later compared with the air kerma measured in an industrial irradiator. This industrial X-ray generator was recently used in the implementation of X-radiation Standards beams, mammography level, following the Standard IEC 61267. The HVL values varied from 0.36 (25kV) to 0.41 mmA1 (35kV), and the measured air kerma rates were between 9.78 and 17.97 mGy/min. (author)

  14. Simultaneous bilateral stereotactic procedure for deep brain stimulation implants: a significant step for reducing operation time.

    Science.gov (United States)

    Fonoff, Erich Talamoni; Azevedo, Angelo; Angelos, Jairo Silva Dos; Martinez, Raquel Chacon Ruiz; Navarro, Jessie; Reis, Paul Rodrigo; Sepulveda, Miguel Ernesto San Martin; Cury, Rubens Gisbert; Ghilardi, Maria Gabriela Dos Santos; Teixeira, Manoel Jacobsen; Lopez, William Omar Contreras

    2016-07-01

    OBJECT Currently, bilateral procedures involve 2 sequential implants in each of the hemispheres. The present report demonstrates the feasibility of simultaneous bilateral procedures during the implantation of deep brain stimulation (DBS) leads. METHODS Fifty-seven patients with movement disorders underwent bilateral DBS implantation in the same study period. The authors compared the time required for the surgical implantation of deep brain electrodes in 2 randomly assigned groups. One group of 28 patients underwent traditional sequential electrode implantation, and the other 29 patients underwent simultaneous bilateral implantation. Clinical outcomes of the patients with Parkinson's disease (PD) who had undergone DBS implantation of the subthalamic nucleus using either of the 2 techniques were compared. RESULTS Overall, a reduction of 38.51% in total operating time for the simultaneous bilateral group (136.4 ± 20.93 minutes) as compared with that for the traditional consecutive approach (220.3 ± 27.58 minutes) was observed. Regarding clinical outcomes in the PD patients who underwent subthalamic nucleus DBS implantation, comparing the preoperative off-medication condition with the off-medication/on-stimulation condition 1 year after the surgery in both procedure groups, there was a mean 47.8% ± 9.5% improvement in the Unified Parkinson's Disease Rating Scale Part III (UPDRS-III) score in the simultaneous group, while the sequential group experienced 47.5% ± 15.8% improvement (p = 0.96). Moreover, a marked reduction in the levodopa-equivalent dose from preoperatively to postoperatively was similar in these 2 groups. The simultaneous bilateral procedure presented major advantages over the traditional sequential approach, with a shorter total operating time. CONCLUSIONS A simultaneous stereotactic approach significantly reduces the operation time in bilateral DBS procedures, resulting in decreased microrecording time, contributing to the optimization of functional

  15. MATLAB-implemented estimation procedure for model-based assessment of hepatic insulin degradation from standard intravenous glucose tolerance test data.

    Science.gov (United States)

    Di Nardo, Francesco; Mengoni, Michele; Morettini, Micaela

    2013-05-01

    Present study provides a novel MATLAB-based parameter estimation procedure for individual assessment of hepatic insulin degradation (HID) process from standard frequently-sampled intravenous glucose tolerance test (FSIGTT) data. Direct access to the source code, offered by MATLAB, enabled us to design an optimization procedure based on the alternating use of Gauss-Newton's and Levenberg-Marquardt's algorithms, which assures the full convergence of the process and the containment of computational time. Reliability was tested by direct comparison with the application, in eighteen non-diabetic subjects, of well-known kinetic analysis software package SAAM II, and by application on different data. Agreement between MATLAB and SAAM II was warranted by intraclass correlation coefficients ≥0.73; no significant differences between corresponding mean parameter estimates and prediction of HID rate; and consistent residual analysis. Moreover, MATLAB optimization procedure resulted in a significant 51% reduction of CV% for the worst-estimated parameter by SAAM II and in maintaining all model-parameter CV% MATLAB-based procedure was suggested as a suitable tool for the individual assessment of HID process. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  16. Development and evaluation of Standard Operating Procedures (SOPs) for quality control tests and radiological protection activities in a Nuclear Medicine Service

    Energy Technology Data Exchange (ETDEWEB)

    Krempser, Alexandre R., E-mail: krempser@peb.ufrj.br [Universidade Federal do Rio de Janeiro (PEB/COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Biomedica; Soares, Alexandre B. [Universidade Federal do Rio de Janeiro (IF/UFRJ), Rio de Janeiro, RJ (Brazil). Inst. de Fisica; Corbo, Rossana [Universidade Federal do Rio de Janeiro (FM/UFRJ), Rio de Janeiro, RJ (Brazil). Dept. de Radiologia

    2011-07-01

    The quality management in Nuclear Medicine Services is a requirement of national and international standards. The Brazilian regulatory agency in health surveillance, the Agencia Nacional de Vigilancia Sanitaria (ANVISA), in its Resolucao de Diretoria Colegiada (Collegiate Directory Resolution) no. 38, requires the elaboration of documents describing the technical and clinical routine activities. This study aimed to elaborate, implement and evaluate Standard Operating Procedures (SOPs) for quality control tests and radiological protection activities in the Nuclear Medicine Service of a university hospital. Eighteen SOPs were developed, involving tasks related to dose calibrator, gamma camera, Geiger-Muller detectors and radiological protection activities. The performance of its application was evaluated for a period of six months. It was observed a reduction in 75% of reported operational errors and 42% of the number of reported incidents with contamination by radioactive material. The SOPs were adequate and successful in its application. New procedures involving clinical activities will also be developed and evaluated. (author)

  17. Biomass Compositional Analysis Laboratory Procedures | Bioenergy | NREL

    Science.gov (United States)

    Biomass Compositional Analysis Laboratory Procedures Biomass Compositional Analysis Laboratory Procedures NREL develops laboratory analytical procedures (LAPs) for standard biomass analysis. These procedures help scientists and analysts understand more about the chemical composition of raw biomass

  18. The Bentall procedure in patients with Marfan's syndrome.

    Science.gov (United States)

    Nguyen, K H; Ergin, M A; Galla, J D; Lansman, S L; McCullough, J N; Griepp, R B

    1997-01-01

    From 1985 to 1996, 18 patients with Marfan's syndrome underwent the Bentall procedure at Mount Sinai Hospital. They are compared with 38 patients aged Marfan's syndrome who also underwent composite valve-graft replacement of the ascending aorta. The mean age of the non-Marfan group was 33 while that of the Marfan group was 29. Nearly three-quarters of each group were male. Aortic dissection was present in 33% of the Marfan group but only in 18% of the other group. Seventy-eight percent of the Marfan patients and 89% of the non-Marfan patients had aortic regurgitation. Twenty-one percent of the patients in the control group nevertheless had gross aortic pathology suggestive of Marfan's syndrome and may have had variants of the syndrome; 26% of the non-Marfan group had a bicuspid aortic valve. A modification of the Bentall procedure with implantation of coronary artery buttons was performed in the majority of the patients in both groups. Three patients, all in the group with Marfan's syndrome, required a concomitant mitral valve procedure. There was one death in each group. Two non-Marfan patients required reoperation; neither had dissection. Four patients with Marfan's syndrome underwent reoperation for distal disease in the aorta; they comprised one third of the Marfan patients who had aortic dissection. Three late complications occurred in the group with Marfan's syndrome: progressive cardiomyopathy; myocardial infarction; and late tamponade. There were also two late sudden deaths in the group with Marfan's syndrome, which may have been the consequence of aortic rupture. No difference in immediate operative mortality following the Bentall procedure was noted between patients with and without Marfan's syndrome, but young patients without Marfan's syndrome seem to have better event-free and long-term survival. In patients with Marfan's syndrome, the presence of acute dissection makes reoperation more likely, and sudden death from rupture still occurs despite careful

  19. 21 CFR 58.81 - Standard operating procedures.

    Science.gov (United States)

    2010-04-01

    ...) Data handling, storage, and retrieval. (11) Maintenance and calibration of equipment. (12) Transfer... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Testing Facilities Operation § 58.81 Standard... forth nonclinical laboratory study methods that management is satisfied are adequate to insure the...

  20. Renal carcinoma infiltrating inferior vena cava and combined valvular heart disease - one-stage uro-cardiological procedure: a case report

    Directory of Open Access Journals (Sweden)

    Zapala Lukasz

    2010-07-01

    Full Text Available Abstract Standard treatment of patients with coexisting cardiac and non-cardiac diseases includes two separate operations. We report a case of 55-year-old man with combined valvular heart disease and renal carcinoma infiltrating inferior caval vein, who underwent one-stage cardio-urologic procedure. In the first step, mitral and tricuspid valvuloplasty were performed by cardiac surgeons. Then, urologists performed radical nephrectomy and thrombectomy. The postoperative course was uneventful. In twelve months follow-up the patient shows no signs of reccurrence and he had no symptoms of cardiac disease. To the best of our knowledge such a case has never been reported before in the literature.

  1. Premenarchal vaginal discharge: findings of procedures to rule out foreign bodies.

    Science.gov (United States)

    Smith, Yolanda R; Berman, Deborah R; Quint, Elisabeth H

    2002-08-01

    Vaginal discharge in children is a common gynecologic complaint and may be resistant to symptomatic and/or antibiotic treatment. In recurrent or unresponsive patients, an evaluation to rule out a foreign body is traditionally recommended. The objective of this study is to review cases of vaginal discharge referred to our institution and assess outcome and diagnosis in those who required irrigation or vaginoscopy to rule out a foreign body.A retrospective chart review was performed on all premenarchal girls identified through the University of Michigan Pediatric and Adolescent Gynecology Clinic database who were seen for evaluation of vaginal discharge between June 1996 and December 2001. The records were reviewed for age, length of time of discharge, aspects of discharge, procedures done to rule out foreign bodies, and findings of such procedures. The study was performed in a tertiary care university hospital. Forty-one premenarchal girls were evaluated for vaginal discharge. The average age was 6.0 yr (range 3 months-11 yr). The average duration of vaginal discharge prior to presentation was 13.7 months (range 1-42 months). Of the 41 girls, 18 girls underwent 1 procedure each, 2 girls underwent 2 procedures each, and 1 girl underwent 5 procedures. Ten vaginal irrigations in clinic were performed in 7 girls, 3 by the referring physician and 7 by us. These irrigations removed a foreign body (tissue paper) in 4 of 10 (40%) cases, 3 at our institution and 1 at an outside institution. In the three irrigation cases with foreign bodies performed at our institution, the foreign body was visible on genital examination prior to the irrigation. Seventeen vaginoscopies under anesthesia were performed in 16 girls, 5 by the referring physician and 12 by us. In the girls who underwent a vaginoscopy under anesthesia a foreign body was found in 3 of 17 (17.6%). The other findings of the vaginoscopies included: biopsy-proven severe dermatitis with no infection in 1 patient

  2. Chapter 1. Introduction. Recommendations and standard operating procedures for intensive care unit and hospital preparations for an influenza epidemic or mass disaster

    NARCIS (Netherlands)

    Sprung, Charles L.; Cohen, Robert; Adini, Bruria; Christian, Michael D.; Camargo, Ruben; Ceraso, Daniel; Azoulay, Elie; Duguet, Alexandre; Guery, Benoit; Reinhart, Konrad; Barlavie, Yaron; Benin-Goren, Odeda; Klein, Motti; Leoniv, Yuval; Margalit, Gila; Rubinovitch, Bina; Sonnenblick, Moshe; Steinberg, Avraham; Weissman, Charles; Wolff, Donna; Kesecioglu, Jozef; de Jong, Menno; Moreno, Rui; An, Youzhong; Du, Bin; Joynt, Gavin M.; Colvin, John; Loo, Shi; Richards, Guy; Artigas, Antonio; Pugin, Jerome; Amundson, Dennis; Devereaux, Asha; Beigel, John; Danis, Marion; Farmer, Chris; Hick, John L.; Maki, Dennis; Masur, Henry; Rubinson, Lewis; Sandrock, Christian; Talmor, Daniel; Truong, Robert; Zimmerman, Janice; Brett, Steve; Montgomery, Hugh; Rhodes, Andrew; Sanderson, Frances; Taylor, Bruce; Monrgomery, Hugh

    2010-01-01

    In December 2007, the European Society of Intensive Care Medicine established a Task Force to develop standard operating procedures (SOPs) for operating intensive care units (ICU) during an influenza epidemic or mass disaster. To provide direction for health care professionals in the preparation and

  3. Substitution urethroplasty of complex and long-segment urethral strictures: a rationale for procedure selection.

    Science.gov (United States)

    Xu, Yue-Min; Qiao, Yong; Sa, Ying-Long; Wu, Den-Long; Zhang, Xin-Ru; Zhang, Jion; Gu, Bao-Jun; Jin, San-Bao

    2007-04-01

    We evaluated the applications and outcomes of substitution urethroplasty, using a variety of techniques, in 65 patients with complex, long-segment urethral strictures. From January 1995 to December 2005, 65 patients with complex urethral strictures >8cm in length underwent substitution urethroplasty. Of the 65 patients, 43 underwent one-stage urethral reconstruction using mucosal grafts (28 colonic mucosal graft, 12 buccal mucosal graft, and 3 bladder mucosal graft), 17 patients underwent one-stage urethroplasty using pedicle flaps, and 5 patients underwent staged Johanson's urethroplasty. The mean follow-up time was 4.8 yr (range; 0.8-10 yr), with an overall success rate of 76.92% (50 of 65 cases). Complications developed in 15 patients (23.08%) and included recurrent stricture in 7 (10.77%), urethrocutaneous fistula in 3 (4.62%), coloabdominal fistula in 1 (1.54%), penile chordee in 2 (3.08%), and urethral pseudodiverticulum in 2 (3.08%). Recurrent strictures and urethral pseudodiverticulum were treated successfully with a subsequent procedure, including repeat urethroplasty in six cases and urethrotomy or dilation in three. Coloabdominal fistula was corrected only by dressing change; five patients await further reconstruction. Penile skin, colonic mucosal, and buccal mucosal grafts are excellent materials for substitution urethroplasty. Colonic mucosal graft urethroplasty is a feasible procedure for complicated urethral strictures involving the entire or multiple portions of the urethra and the technique may also be considered for urethral reconstruction in patients in whom other conventional procedures failed.

  4. Surgical reconstruction of pressure ulcer defects: a single- or two-stage procedure?

    LENUS (Irish Health Repository)

    Laing, Tereze A

    2012-02-01

    BACKGROUND: The surgical management of pressure ulcers traditionally involved staged procedures, with initial debridement of necrotic or infected material followed by reconstruction at a later date when the wound was deemed viable and free of gross infection. However, over the past decade, it has been suggested that a single-stage procedure, combining initial debridement and definitive reconstruction, may provide advantages over staged surgery. We present our experience with the staged approach and review the current evidence for both methods. SUBJECTS AND SETTINGS: : We reviewed medical records of all patients referred to our service for pressure ulcer management between October 2001 and October 2007. The National Rehabilitation Hospital is the national center in Ireland for primary rehabilitation of adults and children suffering from spinal and brain injury, serving patients locally and from around the country. METHODS: All subjects who were managed surgically underwent a 2-stage procedure, with initial debridement and subsequent reconstruction. The main outcome measures were length of hospital stay, postoperative morbidity and mortality, and time to complete ulcer healing. RESULTS: Forty-one of 108 patients with 58 pressure ulcers were managed surgically. All patients underwent initial surgical debridement and 20 patients underwent subsequent pressure ulcer reconstruction. Postreconstructive complications occurred in 5 patients (20%). The mean time to complete ulcer healing was 17.4 weeks. Partial flap necrosis occurred in 3 patients, but there were no episodes of flap failure. CONCLUSIONS: We achieved favorable results with a 2-stage reconstruction technique and suggest that the paucity of evidence related to single-stage procedures does not support a change in surgical management.

  5. Painful procedures can affect post-natal growth and neurodevelopment in preterm infants.

    Science.gov (United States)

    Coviello, Caterina; Popple Martinez, Marina; Drovandi, Livia; Corsini, Iuri; Leonardi, Valentina; Lunardi, Clara; Antonelli, Carla; Pratesi, Simone; Dani, Carlo

    2018-05-01

    This Italian study evaluated whether painful procedures during the first four weeks of life were related to subsequent weight gain, head circumference (HC) and neurodevelopmental outcomes in preterm infants, METHODS: We evaluated the number of invasive procedures that infants born at less than 32 weeks of gestational age (GA) underwent in the Neonatal Intensive Care Unit of Careggi Hospital, Florence, from January to December 2015. Weight and HC were recorded at birth, 36 weeks of PMA and six and 12 months of CA. Neurological outcomes were assessed at six and 12 months of CA using the Bayley Scales of Infant and Toddler Development - Third Edition. We studied 83 preterm infants with a GA of 28 ± 2 weeks and birth weight of 1098 ± 340 g. A higher number of invasive painful procedures were related to a lower HC standard deviation score at 36 weeks of PMA and six and 12 months of CA and with lower cognitive scores at six months. At 12 months, the relationship only remained significant for infants born at less than 28 weeks (p growth and short-term cognitive scores in preterm infants in the first year of life. ©2018 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  6. Sexual Desire and Hypoactive Sexual Desire Disorder in Women. Introduction and Overview. Standard Operating Procedure (SOP Part 1)

    DEFF Research Database (Denmark)

    Bitzer, Johannes; Giraldi, Annamaria; Pfaus, Jim

    2013-01-01

    Introduction.  Hypoactive sexual desire disorder (HSDD) is defined in Diagnostic and Statistical Manual of Mental Disorders Fourth Edition as persistent or recurrent deficiency (or absence) of sexual fantasies/thoughts, and/or desire for or receptivity to sexual activity, which causes personal...... must be based on a biopsychosocial, multidimensional, and integrative perspective. Bitzer J, Giraldi A, and Pfaus J. Sexual desire and hypoactive sexual desire disorder in women. Introduction and overview. Standard operating procedure (SOP part 1). J Sex Med **;**:**-**....

  7. Ultrastructural Changes and Corneal Wound Healing After SMILE and PRK Procedures.

    Science.gov (United States)

    Wei, Shengsheng; Wang, Yan; Wu, Di; Zu, PeiPei; Zhang, Hui; Su, Xiaolian

    2016-10-01

    To compare keratocyte activation, cellular morphologic changes and wound healing after SMILE and PRK procedures using transmission electron microscope (TEM). In this study, 22 New Zealand white rabbits (10- to 15-week old) were used. The right eyes of all animals underwent SMILE procedure and the left eyes underwent PRK procedure. Cornea samples taken 1 day and 1 week postoperatively were examined using TEM. Using TEM 1 day after SMILE procedure, the organization of collagen fibers seemed to have been preserved without thermal alterations. Keratocyte activation was observed in the anterior stroma. Disrupted collagen arrangement and debris of cells are visible in the area of damage, and some phagocytic cells and a large number of secondary lysosomes are visible in those cells. At the perimeter zone of the interface, many coenocytes and collagen fragments could be found within the phagocytic cell. One week after SMILE procedure, potential lacuna could be discerned. A large part of the interface of the lenticule extracted had an appearance of clearly being adhered to some mucus secretions. One day after PRK procedure, an irregular epithelial surface was visible using TEM. Keratocytes had been activated and the rough endoplasmic reticulum in those cells had expanded. One week after PRK procedure, the epithelial surface still was irregular and keratinization of the epithelium was still visible in some areas. Corneal endothelium cells were mildly damaged and some vacuoles within the cytoplasm could be discerned. In the anterior stroma, some unhealthy activated keratocytes could still be observed. New collagen fibrils were found present near the activated keratocytes. Using TEM, keratocyte activation could still be observed after SMILE compared to after PRK procedure. Fewer cellular ultrastructural changes were seen after SMILE procedure. Unlike in PRK procedure, no damaged epithelium and endothelium were found after SMILE.

  8. EVALUATION OF OUTCOME OF VARIOUS SURGICAL PROCEDURES FOR UPPER EYELID PTOSIS

    Directory of Open Access Journals (Sweden)

    Nagaraju

    2015-02-01

    Full Text Available INTRODUCTION: There are various procedures available for ptosis correction. Successful outcome not only depends on correct technique but also choosing appropriate procedure for each patient. Selection of procedure is based on available levator function and also other factors like etiology, severity, Bell’s phenomenon etc. If such varied procedure s are performed in a group of patients based on standard criteria and results are evaluated systematically we can determine what works best for a given patient . AIM : Evaluation of outcome of various surgical procedures for upper eyelid ptosis . METHODOLOGY : 25 eyelids of 20 patients who presented to a tertiary centre in south India with complaint of drooping of upper lid were considered. All subjects underwent complete ocular examination corrected visual acuity and detailed ptosis evaluation with particular emphasis on measurement of levator muscle function, MRD1 (margin reflex distance - 1, palpebral fissure width in different gazes and margin crease distance. The effect of various factors like MRD1, MCD, levator function were assessed, the amount of correction required and appropriate surgical procedure was chosen. Surgical procedure of Levator resection, frontalis sling operation, anterior levator aponeurosis advancement, o r other ptosis correction procedures under appropriate anaesthesia were performed. Post - operative evaluation in terms of visual acuity, MRD, Interpalpebral fissure height, lid symmetry, lagophthalmos and complications (if any was done. RESULTS : Levator muscle resection was done in 28% of eyelids, frontal sling surgery in 60% of eyelids, Levator muscle plication in 8% eyelids and levator muscle disinsertion with frontal sling surgery in 4% eyes. Undercorrection was seen in about 44% of eyelids in varying degrees. 56% of the eyes had optimal correction. Symmetric correction was achieved in 76% of eyelids. CONCLUSION: The influence of various preoperative factors on the

  9. Chapter 4. Manpower. Recommendations and standard operating procedures for intensive care unit and hospital preparations for an influenza epidemic or mass disaster

    NARCIS (Netherlands)

    Sandrock, Christian; Christian, Michael D.; Camargo, Ruben; Ceraso, Daniel; Azoulay, Elie; Duguet, Alexandre; Guery, Benoit; Reinhart, Konrad; Adini, Bruria; Barlavie, Yaron; Benin-Goren, Odeda; Cohen, Robert; Klein, Motti; Leoniv, Yuval; Margalit, Gila; Rubinovitch, Bina; Sonnenblick, Moshe; Sprung, Charles L.; Steinberg, Avraham; Weissman, Charles; Wolff, Donna; Kesecioglu, Jozef; de Jong, Menno; Moreno, Rui; An, Youzhong; Du, Bin; Joynt, Gavin M.; Colvin, John; Loo, Shi; Richards, Guy; Artigas, Antonio; Pugin, Jerome; Amundson, Dennis; Devereaux, Asha; Beigel, John; Danis, Marion; Farmer, Chris; Hick, John L.; Maki, Dennis; Masur, Henry; Rubinson, Lewis; Talmor, Daniel; Truog, Robert; Zimmerman, Janice; Brett, Steve; Montgomery, Hugh; Rhodes, Andrew; Sanderson, Frances; Taylor, Bruce

    2010-01-01

    To provide recommendations and standard operating procedures (SOPs) for intensive care unit (ICU) and hospital preparations for an influenza pandemic or mass disaster with a specific focus on manpower. Based on a literature review and expert opinion, a Delphi process was used to define the essential

  10. Acute myocardial infarctation in patients with critical ischemia underwent lower limb revascularization

    Directory of Open Access Journals (Sweden)

    Esdras Marques Lins

    2013-12-01

    Full Text Available BACKGROUND: Atherosclerosis is the main cause of peripheral artery occlusive disease (PAOD of the lower limbs. Patients with PAOD often also have obstructive atherosclerosis in other arterial sites, mainly the coronary arteries. This means that patients who undergo infrainguinal bypass to treat critical ischemia have a higher risk of AMI. There are, however, few reports in the literature that have assessed this risk properly. OBJECTIVE: The aim of this study was to determine the incidence of acute myocardial infarction in patients who underwent infrainguinal bypass to treat critical ischemia of the lower limbs caused by PAOD. MATERIAL AND METHODS: A total of 64 patients who underwent 82 infrainguinal bypass operations, from February 2011 to July 2012 were studied. All patients had electrocardiograms and troponin I blood assays during the postoperative period (within 72 hours. RESULTS: There were abnormal ECG findings and elevated blood troponin I levels suggestive of AMI in five (6% of the 82 operations performed. All five had conventional surgery. The incidence of AMI as a proportion of the 52 conventional surgery cases was 9.6%. Two patients died. CONCLUSION: There was a 6% AMI incidence among patients who underwent infrainguinal bypass due to PAOD. Considering only cases operated using conventional surgery, the incidence of AMI was 9.6%.

  11. Comportamiento de los pacientesancianosoperados de cirugíacardíaca con circulaciónextracorpórea/ Evolution of elderly patients who underwent cardiac surgery with cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Alain Moré Duarte

    2015-10-01

    Full Text Available Introduction: There is a steady increase in the number of elderly patients with severe cardiovascular diseases who require a surgical procedure to recover some quality of life that allows them a socially meaningful existence, despite the risks. Objectives: To analyze the behavior of elderly patients who underwent cardiac surgery with cardiopulmonary bypass. Method: A descriptive, retrospective, cross-sectional study was conducted with patients over 65 years of age who underwent surgery at the Cardiocentro Ernesto Che Guevara, in Santa Clara, from January 2013 to March 2014. Results: In the study, 73.1% of patients were men; and there was a predominance of subjects between 65 and 70 years of age, accounting for 67.3%. Coronary artery bypass graft was the most prevalent type of surgery and had the longest cardiopulmonary bypass times. Hypertension was present in 98.1% of patients. The most frequent postoperative complications were renal dysfunction and severe low cardiac output, with 44.2% and 34.6% respectively. Conclusions: There was a predominance of men, the age group of 65 to 70 years, hypertension, and patients who underwent coronary artery bypass graft with prolonged cardiopulmonary bypass. Renal dysfunction was the most frequent complication.

  12. Extralevator Abdominal Perineal Excision Versus Standard Abdominal Perineal Excision: Impact on Quality of the Resected Specimen and Postoperative Morbidity.

    Science.gov (United States)

    Habr-Gama, Angelita; São Julião, Guilherme P; Mattacheo, Adrian; de Campos-Lobato, Luiz Felipe; Aleman, Edgar; Vailati, Bruna B; Gama-Rodrigues, Joaquim; Perez, Rodrigo Oliva

    2017-08-01

    Abdominal perineal excision (APE) has been associated with a high risk of positive circumferential resection margin (CRM+) and local recurrence rates in the treatment of rectal cancer. An alternative extralevator approach (ELAPE) has been suggested to improve the quality of resection by avoiding coning of the specimen decreasing the risk of tumor perforation and CRM+. The aim of this study is to compare the quality of the resected specimen and postoperative complication rates between ELAPE and "standard" APE. All patients between 1998 and 2014 undergoing abdominal perineal excision for primary or recurrent rectal cancer at a single Institution were reviewed. Between 1998 and 2008, all patients underwent standard APE. In 2009 ELAPE was introduced at our Institution and all patients requiring APE underwent this alternative procedure (ELAPE). The groups were compared according to pathological characteristics, specimen quality (CRM status, perforation and failure to provide the rectum and anus in a single specimen-fragmentation) and postoperative morbidity. Fifty patients underwent standard APEs, while 22 underwent ELAPE. There were no differences in CRM+ (10.6 vs. 13.6%; p = 0.70) or tumor perforation rates (8 vs. 0%; p = 0.30) between APE and ELAPE. However, ELAPE were less likely to result in a fragmented specimen (42 vs. 4%; p = 0.002). Advanced pT-stage was also a risk factor for specimen fragmentation (p = 0.03). There were no differences in severe (Grade 3/4) postoperative morbidity (13 vs. 10%; p = 0.5). Perineal wound dehiscences were less frequent among ELAPE (52 vs 13%; p < 0.01). Despite short follow-up (median 21 mo.), 2-year local recurrence-free survival was better for patients undergoing ELAPE when compared to APE (87 vs. 49%; p = 0.04). ELAPE may be safely implemented into routine clinical practice with no increase in postoperative morbidity and considerable improvements in the quality of the resected specimen of patients with low rectal

  13. 46 CFR 154.665 - Welding procedures.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Welding procedures. 154.665 Section 154.665 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS... Construction § 154.665 Welding procedures. Welding procedure tests for cargo tanks for a design temperature...

  14. 49 CFR 192.225 - Welding procedures.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Welding procedures. 192.225 Section 192.225... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Welding of Steel in Pipelines § 192.225 Welding procedures. (a) Welding must be performed by a qualified welder in accordance with welding procedures...

  15. 40 CFR 1065.10 - Other procedures.

    Science.gov (United States)

    2010-07-01

    ... importance of pursuing changes to the procedures: (i) Whether supplemental emission standards or other... procedures, such as those of the California Air Resources Board or the International Organization for... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Other procedures. 1065.10 Section 1065...

  16. Complications of hysteroscopic Essure(®) sterilisation: report on 4306 procedures performed in a single centre.

    Science.gov (United States)

    Povedano, B; Arjona, J E; Velasco, E; Monserrat, J A; Lorente, J; Castelo-Branco, C

    2012-06-01

    To analyse the short-, medium- and long-term complications in women undergoing hysteroscopic tubal sterilisation with the Essure(®) device. Retrospective 7-year study. Office hysteroscopic unit in a teaching hospital. A total of 4306 women whoe underwent the Essure(®) sterilisation procedure from 2003 to 2010. Data on the success of the procedure and complications arising from outpatient hysteroscopic sterilisation using the Essure(®) system were collected from consecutive women undergoing the procedure over a 7-year period. Placement rate, successful bilateral tubal occlusion, perioperative adverse events, early postoperative (during the first 3 months of follow-up) and late complications (after the initial 3 months of follow-up). A total of 4108 (96.8%) women completed the standard 3-month follow-up protocol. Only 534 (13%) women had undergone the procedure within the previous year. There were 115 (out of 4306; 2.7%) recorded complications, none of which resulted in the need for hospitalisation or discharge later than 2 hours after the procedure. Vasovagal syncope was the most frequently encountered adverse event, occurring in 85 (2.0%) of 4306 cases. In 19 cases, one device was expelled, with most expulsions (14 out of 19) being detected before or during the 3-month follow-up. Outpatient hysteroscopic sterilisation using the Essure(®) system is safe, with a low rate of complications. © 2012 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2012 RCOG.

  17. Pulmonary homograft stenosis in the Ross procedure: Incidence, clinical impact and predictors in long-term follow-up.

    Science.gov (United States)

    Pardo González, Laura; Ruiz Ortiz, Martin; Delgado, Mónica; Mesa, Dolores; Villalba, Rafael; Rodriguez, Sara; Hidalgo, Francisco J; Alados, Pedro; Casares, Jaime; Suarez de Lezo, Jose

    2017-04-01

    The Ross procedure is used in the treatment of selected patients with aortic valve disease. Pulmonary graft stenosis can appear in the long-term follow-up after the Ross intervention, but the factors involved and its clinical implications are not fully known. To describe the incidence, clinical impact and predictors of homograft stenosis and reintervention after the Ross procedure in a prospective series in a tertiary referral hospital. From 1997 to 2009, 107 patients underwent the Ross procedure (mean age: 30±11 years; 69% men; 21 aged36mmHg) and surgical or percutaneous homograft reintervention. After 15 years of follow-up (median: 11 years), echocardiographic and clinical data were available in 91 (85%) and 104 (98%) patients, respectively: 26/91 (29%) patients developed homograft stenosis; 10/104 (10%) patients underwent 13 homograft reintervention procedures (three patients underwent surgical replacement, three received a percutaneous pulmonary valve and one needed stent implantation). The other three patients underwent two consecutive procedures in follow-up; one died because of a procedure-related myocardial infarction. Rates of survival free from homograft stenosis and reintervention at 1, 5 and 10 years were 96%, 82% and 75% and 99%, 94% and 91%, respectively. Paediatric patients had worse survival free from homograft stenosis (hazard ratio [HR] 3.50, 95% confidence interval [CI]: 1.56-7.90; P=0.002), although there were no significant differences regarding reintervention (HR: 2.01, 95% CI: 0.52-7.78; P=0.31). Younger age of homograft donor was also a stenosis predictor (HR: 0.97, 95% CI: 0.94-0.99; P=0.046). The probabilities of homograft stenosis and reintervention 10 years after the Ross procedure were 29% and 10%, respectively; only one patient had a reintervention-related death. Younger donor and recipient age were associated with a higher rate of stenosis. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  18. Random access procedures and radio access network (RAN) overload control in standard and advanced long-term evolution (LTE and LTE-A) networks

    DEFF Research Database (Denmark)

    Kiilerich Pratas, Nuno; Thomsen, Henning; Popovski, Petar

    2015-01-01

    In this chapter, we describe and discuss the current LTE random access procedure and the Radio Access Network Load Control solution within LTE/LTE-A. We provide an overview of the several considered load control solutions and give a detailed description of the standardized Extended Access Class B...

  19. Improvement of Safety Features in Standard Operation Procedure of Tc-99m Generator

    International Nuclear Information System (INIS)

    Manisah Saedon; Mohd Khairul Hakimi; Shyen, A.K.S.

    2011-01-01

    This paper describes the improvements proposed to the original production procedures for Tc-99m generators. Improvements are intended to add safety and health features for workers into the existing procedures. The difference between the new safe work procedures from the original work procedures; is the concern about the safety and health of employees other than the product safety. One of the suggested safety characteristics is by using the visual aid so that the workers can easily see and read the procedures when they perform their duties, whereas the previous procedures are kept in the manual and difficult to access. The purpose of this paper is to share information about the importance of safety and health features for the workers in the procedures established in addition to provide awareness to all parties involved. (author)

  20. Chapter 9. Educational process. Recommendations and standard operating procedures for intensive care unit and hospital preparations for an influenza epidemic or mass disaster

    NARCIS (Netherlands)

    Richards, Guy A.; Sprung, Charles L.; Christian, Michael D.; Camargo, Ruben; Ceraso, Daniel; Azoulay, Elie; Duguet, Alexandre; Guery, Benoit; Reinhart, Konrad; Adini, Bruria; Barlavie, Yaron; Benin-Goren, Odeda; Cohen, Robert; Klein, Motti; Leoniv, Yuval; Margalit, Gila; Rubinovitch, Bina; Sonnenblick, Moshe; Steinberg, Avraham; Weissman, Charles; Wolff, Donna; Kesecioglu, Jozef; de Jong, Menno; Moreno, Rui; An, Youzhong; Du, Bin; Joynt, Gavin M.; Colvin, John; Loo, Shi; Richards, Guy; Artigas, Antonio; Pugin, Jerome; Amundson, Dennis; Devereaux, Asha; Beigel, John; Danis, Marion; Farmer, Chris; Hick, John L.; Maki, Dennis; Masur, Henry; Rubinson, Lewis; Sandrock, Christian; Talmor, Daniel; Truog, Robert; Zimmerman, Janice; Brett, Steve; Montgomery, Hugh; Rhodes, Andrew; Sanderson, Frances; Taylor, Bruce

    2010-01-01

    To provide recommendations and standard operating procedures (SOPs) for intensive care unit (ICU) and hospital preparations for an influenza pandemic or mass disaster with focus on education of all stakeholders, specifically the emergency executive control groups, ICU staff and staff co-opted to

  1. Consistency Across Standards or Standards in a New Business Model

    Science.gov (United States)

    Russo, Dane M.

    2010-01-01

    Presentation topics include: standards in a changing business model, the new National Space Policy is driving change, a new paradigm for human spaceflight, consistency across standards, the purpose of standards, danger of over-prescriptive standards, a balance is needed (between prescriptive and general standards), enabling versus inhibiting, characteristics of success-oriented standards, characteristics of success-oriented standards, and conclusions. Additional slides include NASA Procedural Requirements 8705.2B identifies human rating standards and requirements, draft health and medical standards for human rating, what's been done, government oversight models, examples of consistency from anthropometry, examples of inconsistency from air quality and appendices of government and non-governmental human factors standards.

  2. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks

    Energy Technology Data Exchange (ETDEWEB)

    Bernini, Patrizia; Bertini, Ivano, E-mail: bertini@cerm.unifi.it; Luchinat, Claudio [University of Florence, Magnetic Resonance Center (CERM) (Italy); Nincheri, Paola; Staderini, Samuele [FiorGen Foundation (Italy); Turano, Paola [University of Florence, Magnetic Resonance Center (CERM) (Italy)

    2011-04-15

    {sup 1}H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  3. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks.

    Science.gov (United States)

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-04-01

    (1)H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0-4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  4. Standard operating procedures for pre-analytical handling of blood and urine for metabolomic studies and biobanks

    International Nuclear Information System (INIS)

    Bernini, Patrizia; Bertini, Ivano; Luchinat, Claudio; Nincheri, Paola; Staderini, Samuele; Turano, Paola

    2011-01-01

    1 H NMR metabolic profiling of urine, serum and plasma has been used to monitor the impact of the pre-analytical steps on the sample quality and stability in order to propose standard operating procedures (SOPs) for deposition in biobanks. We analyzed the quality of serum and plasma samples as a function of the elapsed time (t = 0−4 h) between blood collection and processing and of the time from processing to freezing (up to 24 h). The stability of the urine metabolic profile over time (up to 24 h) at various storage temperatures was monitored as a function of the different pre-analytical treatments like pre-storage centrifugation, filtration, and addition of the bacteriostatic preservative sodium azide. Appreciable changes in the profiles, reflecting changes in the concentration of a number of metabolites, were detected and discussed in terms of chemical and enzymatic reactions for both blood and urine samples. Appropriate procedures for blood derivatives collection and urine preservation/storage that allow maintaining as much as possible the original metabolic profile of the fresh samples emerge, and are proposed as SOPs for biobanking.

  5. Is Office-Based Surgery Safe? Comparing Outcomes of 183,914 Aesthetic Surgical Procedures Across Different Types of Accredited Facilities.

    Science.gov (United States)

    Gupta, Varun; Parikh, Rikesh; Nguyen, Lyly; Afshari, Ashkan; Shack, R Bruce; Grotting, James C; Higdon, K Kye

    2017-02-01

    There has been a dramatic rise in office-based surgery. However, due to wide variations in regulatory standards, the safety of office-based aesthetic surgery has been questioned. This study compares complication rates of cosmetic surgery performed at office-based surgical suites (OBSS) to ambulatory surgery centers (ASCs) and hospitals. A prospective cohort of patients undergoing cosmetic surgery between 2008 and 2013 were identified from the CosmetAssure database (Birmingham, AL). Patients were grouped by type of accredited facility where the surgery was performed: OBSS, ASC, or hospital. The primary outcome was the incidence of major complication(s) requiring emergency room visit, hospital admission, or reoperation within 30 days postoperatively. Potential risk factors including age, gender, body mass index (BMI), smoking, diabetes, type of procedure, and combined procedures were reviewed. Of the 129,007 patients (183,914 procedures) in the dataset, the majority underwent the procedure at ASCs (57.4%), followed by hospitals (26.7%) and OBSS (15.9%). Patients operated in OBSS were less likely to undergo combined procedures (30.3%) compared to ASCs (31.8%) and hospitals (35.3%, P procedures. Plastic surgeons should continue to triage their patients carefully based on other significant comorbidities that were not measured in this present study. LEVEL OF EVIDENCE 3. © 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  6. Internal Delorme's Procedure for Treating ODS Associated With Impaired Anal Continence.

    Science.gov (United States)

    Liu, Weicheng; Sturiale, Alessandro; Fabiani, Bernardina; Giani, Iacopo; Menconi, Claudia; Naldini, Gabriele

    2017-12-01

    The aim of this study was to evaluate the medium-term outcomes of internal Delorme's procedure for treating obstructed defecation syndrome (ODS) patients with impaired anal continence. In a retrospective study, 41 ODS patients who underwent internal Delorme's procedure between 2011 and 2015 were divided into 3 subgroups according to their associated symptoms of impaired continence, as urgency, passive fecal incontinence and both, before study. Then the patients' preoperative statuses, perioperative complications, and postoperative outcomes were investigated and collected from standardized questionnaires, including Altomare ODS score, Fecal Incontinence Severity Index (FISI), Patient Assessment of Constipation-Quality of Life Questionnaire (PAC-QoL), and Fecal Incontinence Quality of Life Scale (FIQLS). All results with a 2-tailed P ODS score, FISI, PAC-QoL, and FIQLS in all patients when comparing scores from before the operation with those at the final follow-up. Similar results were also observed in both the urgency subgroup and passive fecal incontinence subgroup, but there were no statistically significant improvements ( P > .05) in Altomare ODS score, FISI, PAC-QoL, or FIQLS in the urgency and passive fecal incontinence subgroups. Anorectal manometry showed the mean value of anal resting pressure increased 20%. Additionally, no major complications occurred. Internal Delorme's procedure is effective without major morbidity for treating ODS associated with urgency or passive fecal incontinence, but it may be less effective for treating ODS associated with both urgency and passive fecal incontinence.

  7. The importance of superficial basal cell carcinoma in a retrospective study of 139 patients who underwent Mohs micrographic surgery in a Brazilian university hospital

    Directory of Open Access Journals (Sweden)

    Luciana Takata Pontes

    2015-11-01

    Full Text Available OBJECTIVE: Mohs micrographic surgery is a specialized surgical procedure used to treat skin cancer. The purpose of this study was to better understand the profile of the patients who underwent the procedure and to determine how histology might be related to complications and the number of stages required for complete removal. METHODS: The records of patients who underwent Mohs micrographic surgery from October 2008 to November 2013 at the Dermatology Division of the Hospital of the Campinas University were assessed. The variables included were gender, age, anatomical location, histology, number of stages required and complications. RESULTS: Contingency tables were used to compare the number of stages with the histological diagnosis. The analysis showed that patients with superficial basal cell carcinoma were 9.03 times more likely to require more than one stage. A comparison between complications and histological diagnosis showed that patients with superficial basal cell carcinoma were 6.5 times more likely to experience complications. CONCLUSION: Although superficial basal cell carcinoma is typically thought to represent a less-aggressive variant of these tumors, its propensity for demonstrating “skip areas” and clinically indistinct borders make it a challenge to treat. Its particular nature may result in the higher number of surgery stages required, which may, as a consequence, result in more complications, including recurrence. Recurrence likely occurs due to the inadequate excision of the tumors despite their clear margins. Further research on this subtype of basal cell carcinoma is needed to optimize treatments and decrease morbidity.

  8. Standard measurement procedures for the characterization of fs-laser optical components

    Science.gov (United States)

    Starke, Kai; Ristau, Detlev; Welling, Herbert

    2003-05-01

    Ultra-short pulse laser systems are considered as promising tools in the fields of precise micro-machining and medicine applications. In the course of the development of reliable table top laser systems, a rapid growth of ultra-short pulse applications could be observed during the recent years. The key for improving the performance of high power laser systems is the quality of the optical components concerning spectral characteristics, optical losses and the power handling capability. In the field of ultra-short pulses, standard measurement procedures in quality management have to be validated in respect to effects induced by the extremely high peak power densities. The present work, which is embedded in the EUREKA-project CHOCLAB II, is predominantly concentrated on measuring the multiple-pulse LIDT (ISO 11254-2) in the fs-regime. A measurement facility based on a Ti:Sapphire-CPA system was developed to investigate the damage behavior of optical components. The set-up was supplied with an improved pulse energy detector discriminating the influence of pulse-to-pulse energy fluctuations on the incidence of damage. Aditionally, a laser-calorimetric measurement facility determining the absorption (ISO 11551) utilizing a fs-Ti:Sapphire laser was accomplished. The investigation for different pulse durations between 130 fs and 1 ps revealed a drastic increase of absorption in titania coatings for ultra-short pulses.

  9. Bentall procedure using cryopreserved valved aortic homografts: mid- to long-term results.

    Science.gov (United States)

    Christenson, Jan T; Sierra, Jorge; Trindade, Pedro T; Dominique, Didier; Kalangos, Afksendiyos

    2004-01-01

    The Bentall procedure is the standard operation for patients who have lesions of the ascending aorta associated with aortic valve disease. In many cases, however, mechanical prosthetic conduits are not suitable. There are few reports in the English-language medical literature concerning the mid- to long-term outcome of Bentall operations with cryopreserved homografts. Therefore, we reviewed our experience with this procedure and valved homografts. From January 1997 through December 2002, 21 patients underwent a Bentall operation with cryopreserved homografts at our institution. There were 14 males and 7 females; the mean age was 36 +/- 21 years (range, 15-74 years). Eleven patients had undergone previous aortic valve surgery. All patients had aortic dilatation or aneurysms involving the ascending aorta. Indications for surgery included aortic valve stenosis or insufficiency, and aortic valve endocarditis (native valve or prosthetic). One patient had Takayasu's arteritis and 3 had Marfan syndrome. There was 1 hospital death (due to sepsis), but no other major postoperative complications. The mean hospital stay was 14 +/- 7 days. Follow-up echocardiographic and computed tomographic scans were performed yearly. The mean follow-up was 34 months (6-72 months). Follow-up imaging revealed no calcifications or degenerative processes related to the homograft. Four patients had minimal valve regurgitation. Two patients died during follow-up. The 3-year actuarial survival rate was 85.7%. Our data suggest that the Bentall procedure with a valved homograft conduit is a safe procedure with excellent mid- to long-term results, comparable to results reported with aortic valve replacement with a homograft.

  10. Acucise™ endopyelotomy in a porcine model: procedure standardization and analysis of safety and immediate efficacy

    Directory of Open Access Journals (Sweden)

    Andreoni Cássio

    2004-01-01

    Full Text Available PURPOSE: The study here presented was done to test the technical reliability and immediate efficacy of the Acucise device using a standardized technique. MATERIALS AND METHODS: 56 Acucise procedures were performed in pigs by a single surgeon who used a standardized technique: insert 5F angiographic catheter bilaterally up to the midureter, perform retrograde pyelogram, Amplatz super-stiff guidewire is advanced up to the level of the renal pelvis, angiographic catheters are removed, Acucise catheter balloon is advanced to the ureteropelvic junction (UPJ level, the super-stiff guide-wire is removed and the contrast medium in the renal pelvis is aspirated and replaced with distilled water, activate Acucise at 75 watts of pure cutting current, keep the balloon fully inflated for 10 minutes, perform retrograde ureteropyelogram to document extravasation, remove Acucise catheter and pass an ureteral stent and remove guide-wire. RESULTS: In no case did the Acucise device present malfunction. The electrocautery activation time was 2.2 seconds (ranging from 2 to 4 seconds. The extravasation of contrast medium, visible by fluoroscopy, occurred in 53 of the 56 cases (94.6%. In no case there was any evidence of intraoperative hemorrhage. CONCLUSIONS: This study revealed that performing Acucise endopyelotomy routinely in a standardized manner could largely preclude intraoperative device malfunction and eliminate complications while achieving a successful incision in the UPJ. With the guidelines that were used in this study, we believe that Acucise endopyelotomy can be completed successfully and safely in the majority of selected patients with UPJ obstruction.

  11. A Generalizability Theory Approach to Standard Error Estimates for Bookmark Standard Settings

    Science.gov (United States)

    Lee, Guemin; Lewis, Daniel M.

    2008-01-01

    The bookmark standard-setting procedure is an item response theory-based method that is widely implemented in state testing programs. This study estimates standard errors for cut scores resulting from bookmark standard settings under a generalizability theory model and investigates the effects of different universes of generalization and error…

  12. Intake Procedures in College Counseling Centers.

    Science.gov (United States)

    Pappas, James P.; And Others

    Intake procedures is the common subject of four papers presented in this booklet. James P. Pappas discusses trends, a decision theory model, information and issues in his article "Intake Procedures in Counseling Centers--Trends and Theory." In the second article "The Utilization of Standardized Tests in Intake Procedures or 'Where's the Post…

  13. The impact of a medical procedure service on patient safety, procedure quality and resident training opportunities.

    Science.gov (United States)

    Tukey, Melissa H; Wiener, Renda Soylemez

    2014-03-01

    At some academic hospitals, medical procedure services are being developed to provide supervision for residents performing bedside procedures in hopes of improving patient safety and resident education. There is limited knowledge of the impact of such services on procedural complication rates and resident procedural training opportunities. To determine the impact of a medical procedure service (MPS) on patient safety and resident procedural training opportunities. Retrospective cohort analysis comparing characteristics and outcomes of procedures performed by the MPS versus the primary medical service. Consecutive adults admitted to internal medicine services at a large academic hospital who underwent a bedside medical procedure (central venous catheterization, thoracentesis, paracentesis, lumbar puncture) between 1 July 2010 and 31 December 2011. The primary outcome was a composite rate of major complications. Secondary outcomes included resident participation in bedside procedures and use of "best practice" safety process measures. We evaluated 1,707 bedside procedures (548 by the MPS, 1,159 by the primary services). There were no differences in the composite rate of major complications (1.6 % vs. 1.9 %, p = 0.71) or resident participation in bedside procedures (57.0 % vs. 54.3 %, p = 0.31) between the MPS and the primary services. Procedures performed by the MPS were more likely to be successfully completed (95.8 % vs. 92.8 %, p = 0.02) and to use best practice safety process measures, including use of ultrasound guidance when appropriate (96.8 % vs. 90.0 %, p = 0.0004), avoidance of femoral venous catheterization (89.5 vs. 82.7 %, p = 0.02) and involvement of attending physicians (99.3 % vs. 57.0 %, p < 0.0001). Although use of a MPS did not significantly affect the rate of major complications or resident opportunities for training in bedside procedures, it was associated with increased use of best practice safety process measures.

  14. A standardized model for predicting flap failure using indocyanine green dye

    Science.gov (United States)

    Zimmermann, Terence M.; Moore, Lindsay S.; Warram, Jason M.; Greene, Benjamin J.; Nakhmani, Arie; Korb, Melissa L.; Rosenthal, Eben L.

    2016-03-01

    Techniques that provide a non-invasive method for evaluation of intraoperative skin flap perfusion are currently available but underutilized. We hypothesize that intraoperative vascular imaging can be used to reliably assess skin flap perfusion and elucidate areas of future necrosis by means of a standardized critical perfusion threshold. Five animal groups (negative controls, n=4; positive controls, n=5; chemotherapy group, n=5; radiation group, n=5; chemoradiation group, n=5) underwent pre-flap treatments two weeks prior to undergoing random pattern dorsal fasciocutaneous flaps with a length to width ratio of 2:1 (3 x 1.5 cm). Flap perfusion was assessed via laser-assisted indocyanine green dye angiography and compared to standard clinical assessment for predictive accuracy of flap necrosis. For estimating flap-failure, clinical prediction achieved a sensitivity of 79.3% and a specificity of 90.5%. When average flap perfusion was more than three standard deviations below the average flap perfusion for the negative control group at the time of the flap procedure (144.3+/-17.05 absolute perfusion units), laser-assisted indocyanine green dye angiography achieved a sensitivity of 81.1% and a specificity of 97.3%. When absolute perfusion units were seven standard deviations below the average flap perfusion for the negative control group, specificity of necrosis prediction was 100%. Quantitative absolute perfusion units can improve specificity for intraoperative prediction of viable tissue. Using this strategy, a positive predictive threshold of flap failure can be standardized for clinical use.

  15. Consent for routine neonatal procedures: A study of practices in Irish neonatal units. How do we compare with the gold standard BAPM guidelines?

    Science.gov (United States)

    Ryan, M A; Ryan, C A; Dempsey, E; O'Connell, R

    2017-06-09

    The Irish National Consent Policy (NCP) proposes that the legal requirement for consent extends to all forms of interventions, investigations and treatment, carried out on or behalf of the Health Service Executive (HSE). This study employs a quantitative descriptive approach to investigate the practices for obtaining consent for an identified group of routine neonatal procedures in neonatal facilities throughout Ireland. The BAPM (British Association of Perinatal Medicine) guidelines were identified as 'gold standard' for the purposes of this study. The results indicated a lack of consistency between participating units pertaining to the modes of consent utilised and notable variances from 'gold standard' guidelines. Unanimity was evident for 3 procedures only (administering BCG, 6-in-1, and donor breast milk to infant). Significant findings related to EEG with video recordings, MRI/CT and gastro intestinal imaging, screening of an infant with suspected substance abuse or retinopathy of prematurity screening (ROP), administration of Vitamin K, and the carrying out of a lumbar puncture.

  16. BTS statistical standards manual

    Science.gov (United States)

    2005-10-01

    The Bureau of Transportation Statistics (BTS), like other federal statistical agencies, establishes professional standards to guide the methods and procedures for the collection, processing, storage, and presentation of statistical data. Standards an...

  17. Procedure-related risk of miscarriage following amniocentesis and chorionic villus sampling: a systematic review and meta-analysis.

    Science.gov (United States)

    Akolekar, R; Beta, J; Picciarelli, G; Ogilvie, C; D'Antonio, F

    2015-01-01

    To estimate procedure-related risks of miscarriage following amniocentesis and chorionic villus sampling (CVS) based on a systematic review of the literature and a meta-analysis. A search of MEDLINE, EMBASE, CINHAL and The Cochrane Library (2000-2014) was performed to review relevant citations reporting procedure-related complications of amniocentesis and CVS. Only studies reporting data on more than 1000 procedures were included in this review to minimize the effect of bias from smaller studies. Heterogeneity between studies was estimated using Cochran's Q, the I(2) statistic and Egger bias. Meta-analysis of proportions was used to derive weighted pooled estimates for the risk of miscarriage before 24 weeks' gestation. Incidence-rate difference meta-analysis was used to estimate pooled procedure-related risks. The weighted pooled risks of miscarriage following invasive procedures were estimated from analysis of controlled studies including 324 losses in 42 716 women who underwent amniocentesis and 207 losses in 8899 women who underwent CVS. The risk of miscarriage prior to 24 weeks in women who underwent amniocentesis and CVS was 0.81% (95% CI, 0.58-1.08%) and 2.18% (95% CI, 1.61-2.82%), respectively. The background rates of miscarriage in women from the control group that did not undergo any procedures were 0.67% (95% CI, 0.46-0.91%) for amniocentesis and 1.79% (95% CI, 0.61-3.58%) for CVS. The weighted pooled procedure-related risks of miscarriage for amniocentesis and CVS were 0.11% (95% CI, -0.04 to 0.26%) and 0.22% (95% CI, -0.71 to 1.16%), respectively. The procedure-related risks of miscarriage following amniocentesis and CVS are much lower than are currently quoted. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.

  18. Risk of Venous Thromboembolism and Operative Duration in Patients Undergoing Neurosurgical Procedures.

    Science.gov (United States)

    Bekelis, Kimon; Labropoulos, Nicos; Coy, Shannon

    2017-05-01

    The association of operative duration with the risk of venous thromboembolism (VTE) has not been quantified in neurosurgery. To investigate the association of surgical duration for several neurosurgical procedures and the incidence of VTE. We performed a retrospective cohort study involving patients who underwent neurosurgical procedures from 2005 to 2012 and were registered in the American College of Surgeons National Quality Improvement Project registry. In order to control for confounding, we used multivariable regression models, and propensity score conditioning. During the study period, there were 94 747 patients, who underwent neurosurgical procedures, and met the inclusion criteria. Of these, 1358 (1.0%) developed VTE within 30 days postoperatively. Multivariable logistic regression demonstrated an association of longer operative duration with higher 30-day incidence of VTE (odds ratio [OR], 1.22; 95% confidence interval [CI], 1.19-1.25). Compared with procedures of moderate duration (third quintile, 40-60th percentile), patients undergoing the longest procedures (>80th percentile) had higher odds (OR, 3.15; 95% CI, 2.49-3.99) of developing VTE. The shortest procedures (<20th percentile) were associated with a decreased incidence of VTE (OR, 0.51; 95% CI, 0.27-0.76) in comparison to those of moderate duration. The same associations were present in propensity score-adjusted models, and models stratified by subgroups of cranial, spinal, peripheral nerve, and carotid procedures. In a cohort of patients from a national prospective surgical registry, increased operative duration was associated with increased incidence of VTE for neurosurgical procedures. These results can be used by neurosurgeons to inform operative management, and to stratify patients with regard to VTE risk. Copyright © 2016 by the Congress of Neurological Surgeons

  19. Laparoscopic reversal of Hartmann's procedure

    DEFF Research Database (Denmark)

    Svenningsen, Peter Olsen; Bulut, Orhan; Jess, Per

    2010-01-01

    of Hartmann's procedure as safely as in open surgery and with a faster recovery, shorter hospital stay and less blood loss despite a longer knife time. It therefore seems reasonable to offer patients a laparoscopic procedure at departments which are skilled in laparoscopic surgery and use it for standard...

  20. Robot-assisted procedures in pediatric neurosurgery.

    Science.gov (United States)

    De Benedictis, Alessandro; Trezza, Andrea; Carai, Andrea; Genovese, Elisabetta; Procaccini, Emidio; Messina, Raffaella; Randi, Franco; Cossu, Silvia; Esposito, Giacomo; Palma, Paolo; Amante, Paolina; Rizzi, Michele; Marras, Carlo Efisio

    2017-05-01

    OBJECTIVE During the last 3 decades, robotic technology has rapidly spread across several surgical fields due to the continuous evolution of its versatility, stability, dexterity, and haptic properties. Neurosurgery pioneered the development of robotics, with the aim of improving the quality of several procedures requiring a high degree of accuracy and safety. Moreover, robot-guided approaches are of special interest in pediatric patients, who often have altered anatomy and challenging relationships between the diseased and eloquent structures. Nevertheless, the use of robots has been rarely reported in children. In this work, the authors describe their experience using the ROSA device (Robotized Stereotactic Assistant) in the neurosurgical management of a pediatric population. METHODS Between 2011 and 2016, 116 children underwent ROSA-assisted procedures for a variety of diseases (epilepsy, brain tumors, intra- or extraventricular and tumor cysts, obstructive hydrocephalus, and movement and behavioral disorders). Each patient received accurate preoperative planning of optimal trajectories, intraoperative frameless registration, surgical treatment using specific instruments held by the robotic arm, and postoperative CT or MR imaging. RESULTS The authors performed 128 consecutive surgeries, including implantation of 386 electrodes for stereo-electroencephalography (36 procedures), neuroendoscopy (42 procedures), stereotactic biopsy (26 procedures), pallidotomy (12 procedures), shunt placement (6 procedures), deep brain stimulation procedures (3 procedures), and stereotactic cyst aspiration (3 procedures). For each procedure, the authors analyzed and discussed accuracy, timing, and complications. CONCLUSIONS To the best their knowledge, the authors present the largest reported series of pediatric neurosurgical cases assisted by robotic support. The ROSA system provided improved safety and feasibility of minimally invasive approaches, thus optimizing the surgical

  1. Equipment standards for interventional cardiology

    International Nuclear Information System (INIS)

    Dowling, A.; Gallagher, A.; Walsh, C.; Malone, J.

    2005-01-01

    Interventional radiology has seen rapid growth in cardiology and represents an alternative to hazardous surgery. Recently there has been a substantial growth in the number of procedures being performed and interventional cardiology (IC) procedures are the most common interventional procedures in Europe. Advances in imaging technology have facilitated the development of increasingly complex radiological IC equipment. Currently, the technology is developing at a rate ahead of supporting research, equipment standards and a regulatory framework. International standards play a key role in the design, manufacture and performance of radiological IC equipment. A survey of 12 IC systems (15 imaging chains) was conducted in Irish hospitals. The aim of the study was to assess the imbalance between rapidly advancing technology and existing standards and to propose recommendations for new IC equipment standards. The results demonstrate the need for definitive equipment requirements and standardisation in the design, manufacture, acceptance and maintenance of IC equipment. (authors)

  2. Results of clinical application of the modified maze procedure as concomitant surgery

    Science.gov (United States)

    Bakker, Robbert C.; Akin, Sakir; Rizopoulos, Dimitris; Kik, Charles; Takkenberg, Johanna J.M.; Bogers, Ad J.J.C.

    2013-01-01

    OBJECTIVES Atrial fibrillation is the most common cardiac arrhythmia and is associated with significant morbidity and mortality. The classic cut-and-sew maze procedure is successful in 85–95% of patients. However, the technical complexity has prompted modifications of the maze procedure. The objective of this study was to retrospectively evaluate the clinical safety and efficacy of the maze treatment performed at our institution. METHODS From March 2001 until February 2009, 169 patients underwent a modified maze procedure for atrial fibrillation at the Erasmus MC, Rotterdam. Patient characteristics, surgical procedure and follow-up data were obtained by reviewing the medical charts and consulting with the referring physicians. The efficacy of the procedure as measured by AF recurrence was analysed with a repeated measurements model. The quality of life of the patients was assessed with the SF-36 (a short-form health survey with 36 questions) questionnaire and compared with that of the general Dutch population. RESULTS Of the 169 patients who underwent a modified maze procedure, 163 had their maze procedure as a concomitant procedure. The 30-day mortality rate was 4.7% (n = 8). The rate of post-procedural AF recurrence varied significantly over time (P < 0.0001). Decreased left ventricular function, increased age and higher preoperative creatinine levels were predictors of AF recurrence. Quality of life, as measured with the SF-36 questionnaire, was comparable with that of the Dutch population for all health domains. CONCLUSIONS Concomitant maze is a relatively safe treatment that eliminates atrial fibrillation in the majority of patients, although the probability of recurrent AF increases with the passage of time. Decreased left ventricular function, increased age and higher preoperative creatinine levels are associated with an increased risk of AF recurrence. PMID:23103720

  3. Evaluation of endoscopic laser excision of polypropylene mesh/sutures following anti-incontinence procedures.

    LENUS (Irish Health Repository)

    Davis, N F

    2012-11-01

    We reviewed our experience with and outcome of the largest series to our knowledge of patients who underwent endoscopic laser excision of eroded polypropylene mesh or sutures as a complication of previous anti-incontinence procedures.

  4. Children's experiences of procedural pain management in conjunction with trauma wound dressings.

    Science.gov (United States)

    Nilsson, Stefan; Hallqvist, Carina; Sidenvall, Birgitta; Enskär, Karin

    2011-07-01

    This paper is a report of the experiences of children (5-10 years) of procedural pain when they underwent a trauma wound care session. Procedural pain in conjunction with trauma wound care often induces anxiety and distress in children. Children need to alleviate pain and avoid the development of fear in conjunction with examinations and treatments. The nurse could help children to reach this goal by using the comfort theory, which describes holistic nursing in four contexts: physical, psychospiritual, environmental and sociocultural. Few studies have focused on children's experiences of comforting activities in conjunction with trauma wound dressings. This study was conducted between May 2008 and January 2010. Thirty-nine participants aged 5-10 were consecutively included in this study. The wound care session was standardized for all the participants, and semi-structured qualitative interviews with open-ended questions were conducted with all the children in conjunction with the procedure. All the interviews were transcribed verbatim and analysed with qualitative content analysis. Four themes were identified: clinical competence, distraction, participation and security. The children were helped to reach comforting activities to enhance pain management. Children require more than just analgesics in wound care. They also need to experience security and participation in this context. When children feel clinical competence in wound care, they trust the nurse to carry out the wound dressing and instead can focus on the distraction that increases their positive outcomes. © 2011 Blackwell Publishing Ltd.

  5. Effect of using pump on postoperative pleural effusion in the patients that underwent CABG

    Directory of Open Access Journals (Sweden)

    Mehmet Özülkü

    2015-08-01

    Full Text Available Abstract Objective: The present study investigated effect of using pump on postoperative pleural effusion in patients who underwent coronary artery bypass grafting. Methods: A total of 256 patients who underwent isolated coronary artery bypass grafting surgery in the Cardiovascular Surgery clinic were enrolled in the study. Jostra-Cobe (Model 043213 105, VLC 865, Sweden heart-lung machine was used in on-pump coronary artery bypass grafting. Off-pump coronary artery bypass grafting was performed using Octopus and Starfish. Proximal anastomoses to the aorta in both on-pump and off-pump techniques were performed by side clamps. The patients were discharged from the hospital between postoperative day 6 and day 11. Results: The incidence of postoperative right pleural effusion and bilateral pleural effusion was found to be higher as a count in Group 1 (on-pump as compared to Group 2 (off-pump. But the difference was not statistically significant [P>0.05 for right pleural effusion (P=0.893, P>0.05 for bilateral pleural effusion (P=0.780]. Left pleural effusion was encountered to be lower in Group 2 (off-pump. The difference was found to be statistically significant (P<0.05, P=0.006. Conclusion: Under the light of these results, it can be said that left pleural effusion is less prevalent in the patients that underwent off-pump coronary artery bypass grafting when compared to the patients that underwent on-pump coronary artery bypass grafting.

  6. Policy, Procedures and Standards for Enterprise Information Management

    Science.gov (United States)

    This policy establishes a standard approach for managing information produced by, funded by, or received per regulated reporting and/or federal-wide requirements and subsequently held or cataloged in information management systems by EPA.

  7. Manual of Standard Operating Procedures for Veterinary Drug Residue Analysis (Spanish Edition)

    International Nuclear Information System (INIS)

    2017-01-01

    Laboratories are crucial to national veterinary drug residue monitoring programmes. However, one of the main challenges laboratories encounter is obtaining access to relevant methods of analysis. Thus, in addition to training, providing technical advice and transferring technology, the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture has resolved to develop clear and practical manuals to support Member State laboratories. The Coordinated Research Project (CRP) on Development of Radiometric and Allied Analytical Methods to Strengthen Residue Control Programs for Antibiotic and Anthelmintic Veterinary Drug Residues has developed a number of analytical methods as standard operating procedures (SOPs), which are now compiled here. This publication contains SOPs on chromatographic and spectrometric techniques, as well as radioimmunoassay and associated screening techniques, for various anthelmintic and antimicrobial veterinary drug residue analysis. Some analytical method validation protocols are also included. The publication is primarily aimed at food and environmental safety laboratories involved in testing veterinary drug residues, including under organized national residue monitoring programmes. It is expected to enhance laboratory capacity building and competence through the use of radiometric and complementary tools and techniques. The publication is also relevant for applied research on residues of veterinary drugs in food and environmental samples

  8. Manual of Standard Operating Procedures for Veterinary Drug Residue Analysis (French Edition)

    International Nuclear Information System (INIS)

    2017-01-01

    Laboratories are crucial to national veterinary drug residue monitoring programmes. However, one of the main challenges laboratories encounter is obtaining access to relevant methods of analysis. Thus, in addition to training, providing technical advice and transferring technology, the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture has resolved to develop clear and practical manuals to support Member State laboratories. The Coordinated Research Project (CRP) on Development of Radiometric and Allied Analytical Methods to Strengthen Residue Control Programs for Antibiotic and Anthelmintic Veterinary Drug Residues has developed a number of analytical methods as standard operating procedures (SOPs), which are now compiled here. This publication contains SOPs on chromatographic and spectrometric techniques, as well as radioimmunoassay and associated screening techniques, for various anthelmintic and antimicrobial veterinary drug residue analysis. Some analytical method validation protocols are also included. The publication is primarily aimed at food and environmental safety laboratories involved in testing veterinary drug residues, including under organized national residue monitoring programmes. It is expected to enhance laboratory capacity building and competence through the use of radiometric and complementary tools and techniques. The publication is also relevant for applied research on residues of veterinary drugs in food and environmental samples

  9. Characteristics of Mobile Payment Procedures

    OpenAIRE

    Kreyer, Nina; Pousttchi, Key; Turowski, Klaus

    2002-01-01

    Companies are not going to invest into the development of innovative applications or services unless these can be charged for appropriately. Thus, the existence of standardized and widely accepted mobile payment procedures is crucial for successful business-to-customer mobile commerce. The acceptance of mobile payment procedures depends on costs, security and convenience issues. For the latter, it is important that a procedure can be used over the different payment scenarios mobile commerce, ...

  10. 28 CFR 40.3 - Communication of procedures.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Communication of procedures. 40.3 Section... Standards for Inmate Grievance Procedures § 40.3 Communication of procedures. The written grievance... inmate and employee shall, upon arrival at the institution, receive written notification and an oral...

  11. Nevada Applied Ecology Group procedures handbook for environmental transuranics

    International Nuclear Information System (INIS)

    White, M.G.; Dunaway, P.B.

    1976-10-01

    The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and other biological material. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerning a procedure, it has been included to indicate special studies or applications more complex than the routine standard sampling procedures utilized

  12. Nevada Applied Ecology Group procedures handbook for environmental transuranics

    International Nuclear Information System (INIS)

    White, M.G.; Dunaway, P.B.

    1976-10-01

    The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and others. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerning a procedure, it has been included to indicate special studies or applications perhaps more complex than the routine standard sampling procedures utilized

  13. Laparoscopic sentinel node procedure using a combination of patent blue and radiocolloid in women with endometrial cancer.

    Science.gov (United States)

    Barranger, Emmanuel; Cortez, Annie; Grahek, Dany; Callard, Patrice; Uzan, Serge; Darai, Emile

    2004-03-01

    We assessed the feasibility of a laparoscopic sentinel node (SN) procedure based on the combined use of radiocolloid and patent blue labeling in patients with endometrial cancer. Seventeen patients (median age, 69 years) with endometrial cancer of stage I (16 patients) or stage II (1 patient) underwent a laparoscopic SN procedure based on combined radiocolloid and patent blue injected pericervically. After the SN procedure, all patients underwent complete laparoscopic pelvic lymphadenectomy and either laparoscopically assisted vaginal hysterectomy (16 patients) or laparoscopic radical hysterectomy (1 patient). SNs (mean number per patient, 2.6; range, 1-4) were identified in 16 (94.1%) of the 17 patients. Macrometastases were detected in three SNs from two patients by hematoxylin and eosin staining. In three other patients, immunohistochemical analysis identified six micrometastatic SNs and one SN containing isolated tumor cells. No false-negative SN results were observed. An SN procedure based on a combination of radiocolloid and patent blue is feasible in patients with early endometrial cancer. Combined use of laparoscopy and this SN procedure permits minimally invasive management of endometrial cancer.

  14. The Residual Setup Errors of Different IGRT Alignment Procedures for Head and Neck IMRT and the Resulting Dosimetric Impact

    International Nuclear Information System (INIS)

    Graff, Pierre; Kirby, Neil; Weinberg, Vivian; Chen, Josephine; Yom, Sue S.; Lambert, Louise; Pouliot, Jean

    2013-01-01

    Purpose: To assess residual setup errors during head and neck radiation therapy and the resulting consequences for the delivered dose for various patient alignment procedures. Methods and Materials: Megavoltage cone beam computed tomography (MVCBCT) scans from 11 head and neck patients who underwent intensity modulated radiation therapy were used to assess setup errors. Each MVCBCT scan was registered to its reference planning kVCT, with seven different alignment procedures: automatic alignment and manual registration to 6 separate bony landmarks (sphenoid, left/right maxillary sinuses, mandible, cervical 1 [C1]-C2, and C7-thoracic 1 [T1] vertebrae). Shifts in the different alignments were compared with each other to determine whether there were any statistically significant differences. Then, the dose distribution was recalculated on 3 MVCBCT images per patient for every alignment procedure. The resulting dose-volume histograms for targets and organs at risk (OARs) were compared to those from the planning kVCTs. Results: The registration procedures produced statistically significant global differences in patient alignment and actual dose distribution, calling for a need for standardization of patient positioning. Vertically, the automatic, sphenoid, and maxillary sinuses alignments mainly generated posterior shifts and resulted in mean increases in maximal dose to OARs of >3% of the planned dose. The suggested choice of C1-C2 as a reference landmark appears valid, combining both OAR sparing and target coverage. Assuming this choice, relevant margins to apply around volumes of interest at the time of planning to take into account for the relative mobility of other regions are discussed. Conclusions: Use of different alignment procedures for treating head and neck patients produced variations in patient setup and dose distribution. With concern for standardizing practice, C1-C2 reference alignment with relevant margins around planning volumes seems to be a valid

  15. Postoperative Complications of Beger Procedure

    Directory of Open Access Journals (Sweden)

    Nayana Samejima Peternelli

    2015-01-01

    Full Text Available Introduction. Chronic pancreatitis (CP is considered an inflammatory disease that may cause varying degrees of pancreatic dysfunction. Conservative and surgical treatment options are available depending on dysfunction severity. Presentation of Case. A 36-year-old male with history of heavy alcohol consumption and diagnosed CP underwent a duodenal-preserving pancreatic head resection (DPPHR or Beger procedure after conservative treatment failure. Refractory pain was reported on follow-up three months after surgery and postoperative imaging uncovered stones within the main pancreatic duct and intestinal dilation. The patient was subsequently subjected to another surgical procedure and intraoperative findings included protein plugs within the main pancreatic duct and pancreaticojejunal anastomosis stricture. A V-shaped enlargement and main pancreatic duct dilation in addition to the reconstruction of the previous pancreaticojejunal anastomosis were performed. The patient recovered with no further postoperative complications in the follow-up at an outpatient clinic. Discussion. Main duct and pancreaticojejunal strictures are an unusual complication of the Beger procedure but were identified intraoperatively as the cause of patient’s refractory pain and explained intraductal protein plugs accumulation. Conclusion. Patients that undergo Beger procedures should receive close outpatient clinical follow-up in order to guarantee postoperative conservative treatment success and therefore guarantee an early detection of postoperative complications.

  16. 5 CFR 179.304 - Notification procedures.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Notification procedures. 179.304 Section 179.304 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS CLAIMS COLLECTION STANDARDS Administrative Offset § 179.304 Notification procedures. Before collecting any debt...

  17. 7 CFR 28.162 - Procedure.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Procedure. 28.162 Section 28.162 Agriculture..., TESTING, AND STANDARDS Regulations Under the United States Cotton Standards Act Adjustment of Contract... and in instituting and conducting arbitrations and appeals shall be as prescribed in the articles...

  18. Robot-assisted laparoscopic (RAL) procedures in general surgery.

    Science.gov (United States)

    Alimoglu, Orhan; Sagiroglu, Julide; Atak, Ibrahim; Kilic, Ali; Eren, Tunc; Caliskan, Mujgan; Bas, Gurhan

    2016-09-01

    Robotics was introduced in clinical practice more than two decades ago, and it has gained remarkable popularity for a wide variety of laparoscopic procedures. We report our results of robot-assisted laparoscopic surgery (RALS) in the most commonly applied general surgical procedures. Ninety seven patients underwent RALS from 2009 to 2012. Indications for RALS were cholelithiasis, gastric carcinoma, splenic tumors, colorectal carcinoma, benign colorectal diseases, non-toxic nodular goiter and incisional hernia. Records of patients were analyzed for demographic features, intraoperative and postoperative complications and conversion to open surgery. Forty six female and 51 male patients were operated and mean age was 58,4 (range: 25-88). Ninety three out of 97 procedures (96%) were completed robotically, 4 were converted to open surgery and there were 15 postoperative complications. There was no mortality. Wide variety of procedures of general surgery can be managed safely and effectively by RALS. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Yttrium-90 Radioembolization for Unresectable Standard-chemorefractory Intrahepatic Cholangiocarcinoma: Survival, Efficacy, and Safety Study

    Energy Technology Data Exchange (ETDEWEB)

    Rafi, Shoaib; Piduru, Sarat M. [Emory University School of Medicine, Division of Interventional Radiology and Image Guided Medicine, Department of Radiology (United States); El-Rayes, Bassel; Kauh, John S. [Emory University School of Medicine, Department of Hematology and Medical Oncology (United States); Kooby, David A.; Sarmiento, Juan M. [Emory University School of Medicine, Department of Surgical Oncology in Surgery (United States); Kim, Hyun S., E-mail: kevin.kim@emory.edu [Emory University School of Medicine, Division of Interventional Radiology and Image Guided Medicine, Department of Radiology (United States)

    2013-04-15

    To assess the overall survival, efficacy, and safety of radioembolization with yttrium-90 (Y90) for unresectable standard-chemorefractory intrahepatic cholangiocarcinoma (ICC). Patients with unresectable standard-chemorefractory ICC treated with Y90 were studied. Survival was calculated from the date of first Y90 procedure. Tumor response was assessed with the Response Evaluation Criteria in Solid Tumors criteria on follow-up computed tomography or magnetic resonance imaging scans. National Cancer Institute Common Terminology Criteria (NCI CTCAE), version 3, were used for complications. Statistical analysis was performed by the Kaplan-Meier estimator by the log rank test. Nineteen patients underwent a total of 24 resin-based Y90 treatments. Median survival from the time of diagnosis and first Y90 procedure was 752 {+-} 193 [95 % confidence interval (CI) 374-1130] and 345 {+-} 128 (95 % CI 95-595) days, respectively. Median survival with Eastern Cooperative Oncology Group (ECOG) performance status 1 (n = 15) and ECOG performance status 2 (n = 4) was 450 {+-} 190 (95 % CI 78-822) and 345 {+-} 227 (95 % CI 0-790) days, respectively (p = .214). Patients with extrahepatic metastasis (n = 11) had a median survival of 404 {+-} 309 (95 % CI 0-1010) days versus 345 {+-} 117 (95 % CI 115-575) days for patients without metastasis (n = 8) (p = .491). No mortality was reported within 30 days from first Y90 radioembolization. One patient developed grade 3 thrombocytopenia as assessed by NCI CTCAE. Fatigue and transient abdominal pain were observed in 4 (21 %) and 6 (32 %) patients, respectively. Y90 radioembolization is effective for unresectable standard-chemorefractory ICC.

  20. Bilateral axillary artery aneurysms after Bentall procedure in Marfan syndrome.

    Science.gov (United States)

    Haruki, Takashi; Ito, Hiroshi; Sakata, Kensuke; Kobayashi, Yurio

    2015-11-01

    A man with Marfan syndrome underwent a Bentall procedure for annuloaortic ectasia and severe aortic regurgitation at 43 years of age. Twenty-eight years after the Bentall procedure, he developed bilateral axillary artery aneurysms (length × diameter: right: 80 × 39 mm; left: 103 × 45 mm). Aneurysmectomy and reconstruction of the axillary artery were performed using an artificial vascular graft. Histological examination revealed cystic medial necrosis. The postoperative course was uneventful, but long-term follow-up is necessary. © The Author(s) 2014.

  1. A new approach to household appliance energy test procedures

    Energy Technology Data Exchange (ETDEWEB)

    Ernebrant, S.; Wihlborg, M.

    1999-03-01

    Energy test procedures provides the industry with a method to measure its products energy consumption. The energy test procedures are the technical foundation to every energy standard and labelling system. Depending on which country the product is going to be sold in, the manufacturers must follow different standards. This report concentrates on appliance test procedures, with the main focus on refrigerators. Recently, a new technology -microcontrollers- is undermining the credibility of the test procedures. New features, saving energy in real-life, are not picked up by the test procedures. It is estimated that as much as 30% of energy could be saved with this technology. Microcontrollers have also led to the possibility to circumvent tests. A new model is presented in the report, which handles these energy savings and make it harder cheating on tests. The model divides the test procedure in two parts; hardware tests and software tests, and uses a Matlab/Simulink computer model to calculate the energy consumption. Examples of hardware- and software test methods for refrigerators are described. A refrigerator is used as an example to present the model. The possibility to harmonize the energy standards to one global standard, which could mean substantial savings and make international trade more efficient, is also discussed 24 refs, 30 figs. Examination paper

  2. Operational procedure standard for occurrences involving radioactive materials

    International Nuclear Information System (INIS)

    Piekarz, Leonardo; Rezende, Talita C.; Pinheiro, Christiano J.G.

    2017-01-01

    This study has as objective to analyze more deeply the actions of response to emergencies involving radioactive materials, in the intent to establish a pattern to the actions performed by the military fire fighters of the Military Fire Brigade of Minas Gerais. To met these goals, it has been attempted to analyze the procedures utilized and recommended, nowadays, for the military fire fighters of CBMMG, and through directed studies, to suggest new actions possible to be executed in the local of the emergency in a way that will not expose the garrison to doses of ionizing radiation that may prejudice them. It is a study of bibliographic, exploratory, and also descriptive nature, realized through a qualitative approach. The techniques used for the research were the analysis of institutional documents, norms and other literature produced by renamed entities in the radiologic and biosafety areas. It was then concluded that CBMMG, through simple actions of response, can provide higher quality and safety in the operations involving radiologic accidents, standing out that the implemented actions nowadays are very beneath the capacity of the corporation, due to the lack of knowledge of the matter by the fire fighters. It was proposed, then, that new actions be implemented and instituted as operational procedures to be used on those emergencies, with the objective of provide a higher safety and professionalism in the attendance to emergencies involving radioactive materials. (author)

  3. Operational procedure standard for occurrences involving radioactive materials

    Energy Technology Data Exchange (ETDEWEB)

    Piekarz, Leonardo, E-mail: leonardopbm@yahoo.com.br [Academia de Bombeiros Militar de Minas Gerais, Belo Horizonte, MG (Brazil); Rezende, Talita C.; Pinheiro, Christiano J.G., E-mail: talitacolombi@yahoo.com, E-mail: christrieste@yahoo.it [Universidade Federal do Espirito Santo (CCA/UFES), Alegre, ES (Brazil). Programa de Pós-Graduação em Engenharia Química

    2017-07-01

    This study has as objective to analyze more deeply the actions of response to emergencies involving radioactive materials, in the intent to establish a pattern to the actions performed by the military fire fighters of the Military Fire Brigade of Minas Gerais. To met these goals, it has been attempted to analyze the procedures utilized and recommended, nowadays, for the military fire fighters of CBMMG, and through directed studies, to suggest new actions possible to be executed in the local of the emergency in a way that will not expose the garrison to doses of ionizing radiation that may prejudice them. It is a study of bibliographic, exploratory, and also descriptive nature, realized through a qualitative approach. The techniques used for the research were the analysis of institutional documents, norms and other literature produced by renamed entities in the radiologic and biosafety areas. It was then concluded that CBMMG, through simple actions of response, can provide higher quality and safety in the operations involving radiologic accidents, standing out that the implemented actions nowadays are very beneath the capacity of the corporation, due to the lack of knowledge of the matter by the fire fighters. It was proposed, then, that new actions be implemented and instituted as operational procedures to be used on those emergencies, with the objective of provide a higher safety and professionalism in the attendance to emergencies involving radioactive materials. (author)

  4. Endovascular thrombectomy and post-procedural headache.

    Science.gov (United States)

    Khan, Sabrina; Amin, Faisal Mohammad; Holtmannspötter, Markus; Hansen, Klaus; Florescu, Anna Maria; Fakhril-Din, Zainab; Petersen, Julie Falkenberg; Ghanizada, Hashmat; Ayata, Cenk; Gaist, David; Ashina, Messoud

    2017-12-01

    We investigated the prevalence of post-procedural headache in patients who have undergone thrombectomy for ischemic stroke, and correlated history of migraine with risk of peri-procedural complications. A total of 314 patients underwent thrombectomy at the Danish National Hospital from January 2012 to December 2014. Eligible subjects were phone-interviewed using a purpose-developed semi-structured questionnaire according to the International Classification of Headache Disorders 3, beta version criteria. Among 96 eligible subjects, there was a significant decrease in migraine (p = 0.022) within the first 3 months after EVT compared to 1 year before treatment, which was further evident at interview time (on average 1.6 years after EVT, p = 0.013). A minority of patients experienced headaches for the first time within 3 months of their EVT (migraine 2, TTH 9), which persisted at interview time for subjects with migraine. Out of 12 subjects with peri-procedural complications, 2 had a history of migraine with aura. Thrombectomy leads to a significant decrease in previously known migraine, and new onset of headache in a small subset of patients. A history of migraine does not appear to predispose to peri-procedural complications.

  5. 5 CFR 179.308 - Accelerated procedures.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Accelerated procedures. 179.308 Section 179.308 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS CLAIMS COLLECTION STANDARDS Administrative Offset § 179.308 Accelerated procedures. OPM may make an administrative...

  6. Modified arthroscopic Brostrom procedure.

    Science.gov (United States)

    Lui, Tun Hing

    2015-09-01

    The open modified Brostrom anatomic repair technique is widely accepted as the reference standard for lateral ankle stabilization. However, there is high incidence of intra-articular pathologies associated with chronic lateral ankle instability which may not be addressed by an isolated open Brostrom procedure. Arthroscopic Brostrom procedure with suture anchor has been described for anatomic repair of chronic lateral ankle instability and management of intra-articular lesions. However, the complication rates seemed to be higher than open Brostrom procedure. Modification of the arthroscopic Brostrom procedure with the use of bone tunnel may reduce the risk of certain complications. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  7. Treatment of Pancreatic and Periampullary Cancers at a Community Hospital: Successful Application of Tertiary Care Treatment Standards

    Science.gov (United States)

    Moesinger, Robert C.; Davis, Jan W.; Hill, Britani; Johnston, W. Cory; Gray, Carl; Johnson, Harold; Ingersoll, Leslye; Whipple, Gary; Reilly, Mark; Harris, Robert; Hansen, Vincent

    2011-01-01

    Background. The treatment of pancreatic cancer and other periampullary neoplasms is complex and challenging. Major high-volume cancer centers can provide excellent multidisciplinary care of these patients but almost two-thirds of pancreatic cancer patients are treated at low volume centers. There is very little published data from low volume community cancer programs in regards to the treatment of periampullary cancer. In this study, a review of comprehensive periampullary cancer care at two low volume hospitals with comparison to national standards is presented. Methods. This is a retrospective review of 70 consecutive patients with periampullary neoplasms who underwent surgery over a 5-year period (2006–2010) at two community hospitals. Results. There were 51 successful resections of 70 explorations (73%) including 34 Whipple procedures. Mortality rate was 2.9%. Comparison of these patients to national standards was made in terms of operative mortality, resectability rate, administration of adjuvant therapy, clinical trial participation and overall survival. The results in these patients were comparable to national standards. Conclusions. With adequate commitment of resources and experienced surgical and oncologic practitioners, community cancer centers can meet national tertiary care standards in terms of pancreatic and periampullary cancer care. PMID:22312532

  8. Body Mass Index and Operating Times in Vascular Procedures

    Directory of Open Access Journals (Sweden)

    M. Durup-Dickenson

    Full Text Available : Introduction: The influence of body mass index (BMI on operating times in central and peripheral vascular surgical procedures was investigated. Report: A national cohort of Danish patients who underwent a vascular procedure between 1983 and 2012 was used for analysis. Data were analysed with pairwise comparisons of BMI groups for operating times using the independent samples Kruskall–Wallis test. Discussion: A total of 3,255 carotid endarterectomies; 6,885 central vascular procedures; and 4,488 peripheral bypasses were included for the analysis. Median operating times for carotid endarterectomy and central vascular procedures were, respectively, 5 and 15 minutes longer in obese patients than in normal weight patients. This represents a 7% and 10% increase in median operating times, respectively. Linear and multi-adjusted linear regressions were conducted adjusting for confounders, showing a significant correlation between BMI and operating time. Obesity significantly increased the operating times in carotid endarterectomy and central vascular procedures. These may have ramifications for the individual operative stress but not necessarily on logistical operation planning. Keywords: Body mass index (BMI, Obesity, Operating time, Surgery, Vascular surgical procedures

  9. Chapter 7. Critical care triage. Recommendations and standard operating procedures for intensive care unit and hospital preparations for an influenza epidemic or mass disaster

    NARCIS (Netherlands)

    Christian, Michael D.; Joynt, Gavin M.; Hick, John L.; Colvin, John; Danis, Marion; Sprung, Charles L.; Christian, Micahel D.; Camargo, Ruben; Ceraso, Daniel; Azoulay, Elie; Duguet, Alexandre; Guery, Benoit; Reinhart, Konrad; Adini, Bruria; Barlavie, Yaron; Benin-Goren, Odeda; Cohen, Robert; Klein, Motti; Leoniv, Yuval; Margalit, Gila; Rubinovitch, Bina; Sonnenblick, Moshe; Steinberg, Avraham; Weissman, Charles; Wolff, Donna; Kesecioglu, Jozef; de Jong, Menno; Moreno, Rui; An, Youzhong; Du, Bin; Loo, Shi; Richards, Guy; Artigas, Antonio; Pugin, Jerome; Amundson, Dennis; Devereaux, Asha; Beigel, John; Farmer, Chris; Maki, Dennis; Masur, Henry; Rubinson, Lewis; Sandrock, Christian; Talmor, Daniel; Truog, Robert; Zimmerman, Janice; Brett, Steve; Montgomery, Hugh; Rhodes, Andrew; Sanderson, Frances; Taylor, Bruce

    2010-01-01

    To provide recommendations and standard operating procedures for intensive care unit (ICU) and hospital preparations for an influenza pandemic or mass disaster with a specific focus on critical care triage. Based on a literature review and expert opinion, a Delphi process was used to define the

  10. Comparison of Test Procedures and Energy Efficiency Criteria in Selected International Standards and Labeling Programs for Clothes Washers, Water Dispensers, Vending Machines and CFLs

    Energy Technology Data Exchange (ETDEWEB)

    Fridley, David; Zheng, Nina; Zhou, Nan

    2010-06-01

    Since the late 1970s, energy labeling programs and mandatory energy performance standards have been used in many different countries to improve the efficiency levels of major residential and commercial equipment. As more countries and regions launch programs covering a greater range of products that are traded worldwide, greater attention has been given to harmonizing the specific efficiency criteria in these programs and the test methods for measurements. For example, an international compact fluorescent light (CFL) harmonization initiative was launched in 2006 to focus on collaboration between Australia, China, Europe and North America. Given the long history of standards and labeling programs, most major energy-consuming residential appliances and commercial equipment are already covered under minimum energy performance standards (MEPS) and/or energy labels. For these products, such as clothes washers and CFLs, harmonization may still be possible when national MEPS or labeling thresholds are revised. Greater opportunity for harmonization exists in newer energy-consuming products that are not commonly regulated but are under consideration for new standards and labeling programs. This may include commercial products such as water dispensers and vending machines, which are only covered by MEPS or energy labels in a few countries or regions. As China continues to expand its appliance standards and labeling programs and revise existing standards and labels, it is important to learn from recent international experiences with efficiency criteria and test procedures for the same products. Specifically, various types of standards and labeling programs already exist in North America, Europe and throughout Asia for products in China's 2010 standards and labeling programs, namely clothes washers, water dispensers, vending machines and CFLs. This report thus examines similarities and critical differences in energy efficiency values, test procedure specifications and

  11. Sodium pentothal hypnosis: a procedure for evaluating medical patients with suspected psychiatric co-morbidity.

    Science.gov (United States)

    Russo, M B; Brooks, F R; Fontenot, J P; Dopler, B M; Neely, E T; Halliday, A W

    1997-03-01

    The cases presented here were patients referred for neurologic disability evaluations. They met the three selection criteria presented and underwent the four-phase pentothal hypnosis procedure described and at the conclusion were diagnosed as having psychiatric morbidity. We recommend that the sodium pentothal hypnosis procedure be considered for use whenever there is concern for psychiatric co-morbidity in a patient with presumed physiologic disease.

  12. Standard operating procedures for quality audits of 60Co external beam radiotherapy facilities

    International Nuclear Information System (INIS)

    Larrinaga Cortina, E.F.; Dominguez Hung, L.; Campa Menendez, R.

    2001-01-01

    The use of radiotherapy implies the necessity of rigorous quality standards in its different components, aimed to provide the best possible treatment and avoid potential patients' risks, that could even cause him death. Projects of technical cooperation developed in Cuba and supported by the International Atomic Energy Agency address the implementation of Programs of Quality Assurance (PGC) in radiotherapy services. The establishment of the National Quality Audit Program (PNAC) is a superior stage. The National Control Center for Medical Devices, as the national regulator entity for the control and supervision of medical devices in the National Health System, is responsible for the making and execution of the PNAC. The audit modality selected was the inspection visit in situ due to its intrinsic advantages, our geographical extension and the number of radiotherapy services. This paper presents the methodology for the execution of the PNAC, in form of a Normalized Procedure of Operation (PNO) that defines the objectives, scope, terms and definitions, responsibilities, composition and selection of the auditor team, security's conditions, materials and equipment, steps of the audit execution, results calculation and interpretation, records, etc. (author)

  13. Robotic vascular resections during Whipple procedure

    OpenAIRE

    Allan, Bassan J.; Novak, Stephanie M.; Hogg, Melissa E.; Zeh, Herbert J.

    2018-01-01

    Indications for resection of pancreatic cancers have evolved to include selected patients with involvement of peri-pancreatic vascular structures. Open Whipple procedures have been the standard approach for patients requiring reconstruction of the portal vein (PV) or superior mesenteric vein (SMV). Recently, high-volume centers are performing minimally invasive Whipple procedures with portovenous resections. Our institution has performed seventy robotic Whipple procedures with concomitant vas...

  14. Neurosurgical procedures in Jehovah's Witnesses: the Tema experience.

    Science.gov (United States)

    Andrews, N B

    2009-05-01

    On account of religious reasons, Jehovah Witnesses do not accept blood or blood products; occasionally, they accept reinfusion of autologous blood via a cell saver during surgery. The aim of this study was to document the demographics of Jehovah Witnesses undergoing neurosurgical procedures, the neurosurgical procedures undertaken in Jehovah Witnesses and to evaluate the complications of the procedures. A retrospective audit of the medical records of all Jehovah's Witnesses who underwent neurosurgical procedures at our institution, from January 1st 2000 to December 31st 2006, was carried out. The parameters investigated included demographics, pre and post operative diagnosis, type of neurosurgical procedure and complications. Nineteen patients (fifteen male, four female; male/female 3.8:1) constituted the series. The mean age was 45.8 (range: 20-65) years. A total of 21 procedures were performed; intracranial surgery (33%), spinal surgery (67%). No autotransfusion of blood was given. Lumbar laminectomy for stenosis was the commonest spine procedure, ten (71.4%); craniotomy for tumor excision was the commonest intracranial procedure, six (85.7%). With respect to the whole series, the morbidity rate was 4.7% and the mortality rate was 4.7%; both were from intracranial surgery. It is possible to perform certain types of neurosurgical procedures in Jehovah's Witnesses without increasing the mortality and morbidity rate.

  15. DIEP breast reconstruction following multiple abdominal liposuction procedures

    OpenAIRE

    Farid, Mohammed; Nicholson, Simon; Kotwal, Ashutosh; Akali, Augustine

    2014-01-01

    Objective: Previous abdominal wall surgery is viewed as a contraindication to abdominal free tissue transfer. We present two patients who underwent multiple abdominal liposuction procedures, followed by successful free deep inferior epigastric artery perforator flap. We review the literature pertaining to reliability of abdominal free flaps in those with previous abdominal surgery. Methods: Review of case notes and radiological investigations of two patients, and a PubMed search using the ter...

  16. Randomized trial of one-hour sodium bicarbonate vs standard periprocedural saline hydration in chronic kidney disease patients undergoing cardiovascular contrast procedures.

    Directory of Open Access Journals (Sweden)

    Judith Kooiman

    Full Text Available Guidelines advise periprocedural saline hydration for prevention of contrast induced-acute kidney injury (CI-AKI. We analysed whether 1-hour sodium bicarbonate hydration administered solely prior to intra-arterial contrast exposure is non-inferior to standard periprocedural saline hydration in chronic kidney disease (CKD patients undergoing elective cardiovascular diagnostic or interventional contrast procedures.We performed an open-label multicentre non-inferiority trial between 2011-2014. Patients were randomized to 1 hour pre-procedure sodium bicarbonate hydration (250 ml 1.4%, N = 168 or 4-12 hours saline hydration (1000 ml 0.9%, N = 165 prior to and following contrast administration (2000 ml of saline total. Primary outcome was the relative serum creatinine increase (% 48-96 hours post contrast exposure. Secondary outcomes were: incidence of CI-AKI (serum creatinine increase>25% or >44μmol/L, recovery of renal function, the need for dialysis, and hospital costs within two months follow-up.Mean relative creatinine increase was 3.1% (95%CI 0.9 to 5.2% in the bicarbonate and 1.1% (95%CI -1.2 to 3.5% in the saline arm, mean difference 1.9% (95%CI -1.2 to 5.1%, p-non-inferiority <0.001. CI-AKI occurred in 11 (6.7% patients randomized to sodium bicarbonate and 12 (7.5% to saline (p = 0.79. Renal function did not fully recover in 40.0% and 44.4% of CI-AKI patients, respectively (p = 0.84. No patient required dialysis. Mean costs for preventive hydration and clinical preparation for the contrast procedure were $1158 for sodium bicarbonate vs. $1561 for saline (p < 0.001.Short hydration with sodium bicarbonate prior to elective cardiovascular diagnostic or therapeutic contrast procedures is non-inferior to standard periprocedural saline hydration in CKD patients with respect to renal safety and results in considerable healthcare savings.Netherlands Trial Register (http://www.trialregister.nl/trialreg/index.asp, Nr NTR2699.

  17. Randomized trial of one-hour sodium bicarbonate vs standard periprocedural saline hydration in chronic kidney disease patients undergoing cardiovascular contrast procedures.

    Science.gov (United States)

    Kooiman, Judith; de Vries, Jean-Paul P M; Van der Heyden, Jan; Sijpkens, Yvo W J; van Dijkman, Paul R M; Wever, Jan J; van Overhagen, Hans; Vahl, Antonie C; Aarts, Nico; Verberk-Jonkers, Iris J A M; Brulez, Harald F H; Hamming, Jaap F; van der Molen, Aart J; Cannegieter, Suzanne C; Putter, Hein; van den Hout, Wilbert B; Kilicsoy, Inci; Rabelink, Ton J; Huisman, Menno V

    2018-01-01

    Guidelines advise periprocedural saline hydration for prevention of contrast induced-acute kidney injury (CI-AKI). We analysed whether 1-hour sodium bicarbonate hydration administered solely prior to intra-arterial contrast exposure is non-inferior to standard periprocedural saline hydration in chronic kidney disease (CKD) patients undergoing elective cardiovascular diagnostic or interventional contrast procedures. We performed an open-label multicentre non-inferiority trial between 2011-2014. Patients were randomized to 1 hour pre-procedure sodium bicarbonate hydration (250 ml 1.4%, N = 168) or 4-12 hours saline hydration (1000 ml 0.9%, N = 165) prior to and following contrast administration (2000 ml of saline total). Primary outcome was the relative serum creatinine increase (%) 48-96 hours post contrast exposure. Secondary outcomes were: incidence of CI-AKI (serum creatinine increase>25% or >44μmol/L), recovery of renal function, the need for dialysis, and hospital costs within two months follow-up. Mean relative creatinine increase was 3.1% (95%CI 0.9 to 5.2%) in the bicarbonate and 1.1% (95%CI -1.2 to 3.5%) in the saline arm, mean difference 1.9% (95%CI -1.2 to 5.1%, p-non-inferiority <0.001). CI-AKI occurred in 11 (6.7%) patients randomized to sodium bicarbonate and 12 (7.5%) to saline (p = 0.79). Renal function did not fully recover in 40.0% and 44.4% of CI-AKI patients, respectively (p = 0.84). No patient required dialysis. Mean costs for preventive hydration and clinical preparation for the contrast procedure were $1158 for sodium bicarbonate vs. $1561 for saline (p < 0.001). Short hydration with sodium bicarbonate prior to elective cardiovascular diagnostic or therapeutic contrast procedures is non-inferior to standard periprocedural saline hydration in CKD patients with respect to renal safety and results in considerable healthcare savings. Netherlands Trial Register (http://www.trialregister.nl/trialreg/index.asp), Nr NTR2699.

  18. In-Office Endoscopic Laryngeal Laser Procedures: A Patient Safety Initiative.

    Science.gov (United States)

    Anderson, Jennifer; Bensoussan, Yael; Townsley, Richard; Kell, Erika

    2018-05-01

    Objective To review complications of in-office endoscopic laryngeal laser procedures after implementation of standardized safety protocol. Methods A retrospective review was conducted of the first 2 years of in-office laser procedures at St Michaels Hospital after the introduction of a standardized safety protocol. The protocol included patient screening, procedure checklist with standardized reporting of processes, medications, and complications. Primary outcomes measured were complication rates of in-office laryngeal laser procedures. Secondary outcomes included hemodynamic changes, local anesthetic dose, laser settings, total laser/procedure time, and incidence of sedation. Results A total of 145 in-office KTP procedures performed on 65 patients were reviewed. In 98% of cases, the safety protocol was fully implemented. The overall complication rate was 4.8%. No major complications were encountered. Minor complications included vasovagal episodes and patient intolerance. The rate of patient intolerance resulting early termination of anticipated procedure was 13.1%. Total local anesthetic dose averaged 172.9 mg lidocaine per procedure. The mean amount of laser energy dispersed was 261.2 J, with mean total procedure time of 48.3 minutes. Sixteen percent of patients had preprocedure sedation. Vital signs were found to vary modestly. Systolic blood pressure was lower postprocedure in 13.8% and symptomatic in 4.1%. Discussion The review of our standardized safety protocol has revealed that in-office laser treatment for laryngeal pathology has extremely low complication rates with safe patient outcomes. Implications for Practice The trend of shifting procedures out of the operating room into the office/clinic setting requires new processes designed to promote patient safety.

  19. Philosophy, policies, and procedures - The three P's of flight-deck operations

    Science.gov (United States)

    Degani, Asaf; Wiener, Earl L.

    1991-01-01

    Standard operating procedures are drafted and provided to flightcrews to dictate the manner in which tasks are carried out. Failure to conform to Standard Operating Procedures (SOP) is frequently listed as the cause of violations, incidents, and accidents. However, procedures are often designed piecemeal, rather than being based on a sound philosophy of operations and policies that follow from such a philosophy. A framework of philosophy, policies, and procedures is proposed.

  20. 16 CFR 1031.11 - Procedural safeguards.

    Science.gov (United States)

    2010-01-01

    ....11 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION GENERAL COMMISSION PARTICIPATION AND COMMISSION EMPLOYEE INVOLVEMENT IN VOLUNTARY STANDARDS ACTIVITIES Employee Involvement § 1031.11 Procedural... employees may be involved in voluntary standards activities that will further the objectives and programs of...

  1. Outcome of Patients Underwent Emergency Department Thoracotomy and Its Predictive Factors

    Directory of Open Access Journals (Sweden)

    Shahram Paydar

    2014-08-01

    Full Text Available Introduction: Emergency department thoracotomy (EDT may serve as the last survival chance for patients who arrive at hospital in extremis. It is considered as an effective tool for improvement of traumatic patients’ outcome. The present study was done with the goal of assessing the outcome of patients who underwent EDT and its predictive factors. Methods: In the present study, medical charts of 50 retrospective and 8 prospective cases underwent emergency department thoracotomy (EDT were reviewed during November 2011 to June 2013. Comparisons between survived and died patients were performed by Mann-Whitney U test and the predictive factors of EDT outcome were measured using multivariate logistic regression analysis. P < 0.05 considered statistically significant. Results: Fifty eight cases of EDT were enrolled (86.2% male. The mean age of patients was 43.27±19.85 years with the range of 18-85. The mean time duration of CPR was recorded as 37.12±12.49 minutes. Eleven cases (19% were alive to be transported to OR (defined as ED survived. The mean time of survival in ED survived patients was 223.5±450.8 hours. More than 24 hours survival rate (late survived was 6.9% (4 cases. Only one case (1.7% survived to discharge from hospital (mortality rate=98.3%. There were only a significant relation between ED survival and SBP, GCS, CPR duration, and chest trauma (p=0.04. The results demonstrated that initial SBP lower than 80 mmHg (OR=1.03, 95% CI: 1.001-1.05, p=0.04 and presence of chest trauma (OR=2.6, 95% CI: 1.75-3.16, p=0.02 were independent predictive factors of EDT mortality. Conclusion: The findings of the present study showed that the survival rate of trauma patients underwent EDT was 1.7%. In addition, it was defined that falling systolic blood pressure below 80 mmHg and blunt trauma of chest are independent factors that along with poor outcome.

  2. Groin hematoma after electrophysiological procedures-incidence and predisposing factors.

    Science.gov (United States)

    Dalsgaard, Anja Borgen; Jakobsen, Christina Spåbæk; Riahi, Sam; Hjortshøj, Søren

    2014-10-01

    We evaluated the incidence and predisposing factors of groin hematomas after electrophysiological (EP) procedures. Prospective, observational study, enrolling consecutive patients after EP procedures (Atrial fibrillation: n = 151; Supraventricular tachycardia/Diagnostic EP: n = 82; Ventricular tachycardia: n = 18). Patients underwent manual compression for 10 min and 3 h post procedural bed rest. AF ablations were performed with INR 2-3, ACT > 300, and no protamine sulfate. Adhesive pressure dressings (APDs) were used if sheath size ≥ 10F; procedural time > 120 min; and BMI > 30. Patient-reported hematomas were recorded by a telephone follow-up after 2 weeks. Hematoma developed immediately in 26 patients (10%) and after 14 days significant hematoma was reported in 68 patients (27%). Regression analysis on sex, age, BMI 25, ACT 300, use of APD, sheath size and number, and complicated venous access was not associated with hematoma, either immediately after the procedure or after 14 days. Any hematoma presenting immediately after procedures was associated with patient-reported hematomas after 14 days, odds ratio 18.7 (CI 95%: 5.00-69.8; P hematoma immediately after EP procedures was the sole predictor of patient-reported hematoma after 2 weeks. Initiatives to prevent groin hematoma should focus on the procedure itself as well as post-procedural care.

  3. XML Syntax for Clinical Laboratory Procedure Manuals

    OpenAIRE

    Saadawi, Gilan; Harrison, James H.

    2003-01-01

    We have developed a document type description (DTD) in Extensable Markup Language (XML)1 for clinical laboratory procedures. Our XML syntax can adequately structure a variety of procedure types across different laboratories and is compatible with current procedure standards. The combination of this format with an XML content management system and appropriate style sheets will allow efficient procedure maintenance, distributed access, customized display and effective searching across a large b...

  4. Robotic vascular resections during Whipple procedure.

    Science.gov (United States)

    Allan, Bassan J; Novak, Stephanie M; Hogg, Melissa E; Zeh, Herbert J

    2018-01-01

    Indications for resection of pancreatic cancers have evolved to include selected patients with involvement of peri-pancreatic vascular structures. Open Whipple procedures have been the standard approach for patients requiring reconstruction of the portal vein (PV) or superior mesenteric vein (SMV). Recently, high-volume centers are performing minimally invasive Whipple procedures with portovenous resections. Our institution has performed seventy robotic Whipple procedures with concomitant vascular resections. This report outlines our technique.

  5. Diagnosis and dosimetry of exposure to sulfur mustard: Development of a standard operating procedure for hemoglobin adducts: Exploratory research on albumin and keratin adducts

    NARCIS (Netherlands)

    Noort, D.; Fidder, A.; Jong, L.P.A. de; Schans, G.P. van der; Benschop, H.P.

    2000-01-01

    A standard operating procedure (SOP) for determination of the sulfur mustard adduct to the N-terminal valine in hemoglobin was developed. By using this SOP, it was found that the Nterminal valine adduct in globin of hairless guinea pigs and marmosets which had been exposed to sulfur mustard (0.5

  6. Incidence of Bradycardia and Outcomes of Patients Who Underwent Orbital Atherectomy Without a Temporary Pacemaker.

    Science.gov (United States)

    Lee, Michael S; Nguyen, Heajung; Shlofmitz, Richard

    2017-02-01

    We analyzed the incidence of bradycardia and the safety of patients with severely calcified coronary lesions who underwent orbital atherectomy without the insertion of a temporary pacemaker. The presence of severely calcified coronary lesions can increase the complexity of percutaneous coronary intervention due to the difficulty in advancing and optimally expanding the stent. High-pressure inflations to predilate calcified lesions may cause angiographic complications like perforation and dissection. Suboptimal stent expansion is associated with stent thrombosis and restenosis. Orbital atherectomy safely and effectively modifies calcified plaque to facilitate optimal stent expansion. The incidence of bradycardia in orbital atherectomy is unknown. Fifty consecutive patients underwent orbital atherectomy from February 2014 to September 2016 at our institution, none of whom underwent insertion of a temporary pacemaker. The final analysis included 47 patients in this retrospective study as 3 patients were excluded because of permanent pacemaker implantation. The primary endpoint was significant bradycardia, defined as bradycardia requiring emergent pacemaker placement or a heart rate pacemaker appears to be safe.

  7. Endovascular thrombectomy and post-procedural headache

    DEFF Research Database (Denmark)

    Khan, Sabrina; Amin, Faisal Mohammad; Holtmannspötter, Markus

    2017-01-01

    BACKGROUND: We investigated the prevalence of post-procedural headache in patients who have undergone thrombectomy for ischemic stroke, and correlated history of migraine with risk of peri-procedural complications. A total of 314 patients underwent thrombectomy at the Danish National Hospital from...... January 2012 to December 2014. Eligible subjects were phone-interviewed using a purpose-developed semi-structured questionnaire according to the International Classification of Headache Disorders 3, beta version criteria. FINDINGS: Among 96 eligible subjects, there was a significant decrease in migraine...... (p = 0.022) within the first 3 months after EVT compared to 1 year before treatment, which was further evident at interview time (on average 1.6 years after EVT, p = 0.013). A minority of patients experienced headaches for the first time within 3 months of their EVT (migraine 2, TTH 9), which...

  8. Qualification standard for photovoltaic concentrator modules

    Energy Technology Data Exchange (ETDEWEB)

    McConnell, R.; Kurtz, S.; Bottenberg, W. R.; Hammond, R.; Jochums, S. W.; McDanal, A. J.; Roubideaux, D.; Whitaker, C.; Wohlgemuth, J.

    2000-05-05

    The paper describes a proposed qualification standard for photovoltaic concentrator modules. The standard's purpose is to provide stress tests and procedures to identify any component weakness in photovoltaic concentrator modules intended for power generation applications. If no weaknesses are identified during qualification, both the manufacturer and the customer can expect a more reliable product. The qualification test program for the standard includes thermal cycles, humidity-freeze cycles, water spray, off-axis beam damage, hail impact, hot-spot endurance, as well as electrical tests for performance, ground continuity, isolation, wet insulation resistance, and bypass diodes. Because concentrator module performance can not be verified using solar simulator and reference cell procedures suitable for flat-plate modules, the standard specifies an outdoor I-V test analysis allowing a performance comparison before and after a test procedure. Two options to this complex analysis are the use of a reference concentrator module for side-by-side outdoor comparison with modules undergoing various tests and a dark I-V performance check.

  9. Smoking Habit in Severe Obese after bariatric procedures.

    Science.gov (United States)

    Maniscalco, Mauro; Carratù, Pierluigi; Faraone, Stanislao; Cerbone, Maria Rosaria; Cristiano, Stefano; Zedda, Anna; Resta, Onofrio

    2015-01-01

    Bariatric procedures provide an effective means of short term weight loss and sustained weight control for the morbidly obese. The effect of bariatric procedures on smoking habit in obese subjects is not well known. Therefore, we examined the short term effect of bariatric surgery on smoking habit of severe obese patients up to 12 months from the intervention. Smoking habit was assessed in a cohort of 78 morbid smoking obese patients followed at our clinic for bariatric procedures. They underwent non surgical intra-gastric balloon (IB) or surgical procedures such as lap-band laparoscopic surgery (LAGB) or sleeve gastrectomy/gastric by-pass (SPG). Subjects were administered a written questionnaire about their smoking habit before and 3, 6 and 12 months after the procedures. No differences were found among the three groups at 6 and 12 months after the procedures (IB 21 %, LAGB 6 %, SPG 5 %; and IB 14 %, LAGB 3 %, SPG 5 %). Only after 3 months, the rate of quitting of the IB group was higher than LAGB and SPG groups (36 %, 6 % and 5 %, respectively; p = 0.02). Bariatric procedures have no effects on smoking habit of moderate-to-heavy smoker severe obese patients. The use of other traditional smoking cessation methods in patients undergone to bariatric procedures should be implemented.

  10. 77 FR 56698 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2012-09-13

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  11. 78 FR 66098 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2013-11-04

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  12. 75 FR 22892 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2010-04-30

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  13. 76 FR 59481 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2011-09-26

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  14. 77 FR 2603 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2012-01-18

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  15. 78 FR 2711 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2013-01-14

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  16. 76 FR 27168 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2011-05-10

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  17. Validation of standard operating procedures in a multicenter retrospective study to identify -omics biomarkers for chronic low back pain.

    Directory of Open Access Journals (Sweden)

    Concetta Dagostino

    Full Text Available Chronic low back pain (CLBP is one of the most common medical conditions, ranking as the greatest contributor to global disability and accounting for huge societal costs based on the Global Burden of Disease 2010 study. Large genetic and -omics studies provide a promising avenue for the screening, development and validation of biomarkers useful for personalized diagnosis and treatment (precision medicine. Multicentre studies are needed for such an effort, and a standardized and homogeneous approach is vital for recruitment of large numbers of participants among different centres (clinical and laboratories to obtain robust and reproducible results. To date, no validated standard operating procedures (SOPs for genetic/-omics studies in chronic pain have been developed. In this study, we validated an SOP model that will be used in the multicentre (5 centres retrospective "PainOmics" study, funded by the European Community in the 7th Framework Programme, which aims to develop new biomarkers for CLBP through three different -omics approaches: genomics, glycomics and activomics. The SOPs describe the specific procedures for (1 blood collection, (2 sample processing and storage, (3 shipping details and (4 cross-check testing and validation before assays that all the centres involved in the study have to follow. Multivariate analysis revealed the absolute specificity and homogeneity of the samples collected by the five centres for all genetics, glycomics and activomics analyses. The SOPs used in our multicenter study have been validated. Hence, they could represent an innovative tool for the correct management and collection of reliable samples in other large-omics-based multicenter studies.

  18. Standardization of digestion procedure for the determination of heavy metals in biological materials by atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Khalid, N.; Chaudhri, S.A.

    1999-01-01

    Proper decomposition of the sample is one of the basic requirements of the atomic absorption spectroscopic analysis. In the present studies, heavy metals (Cu, Fe, Mn and Zn) were determined in biological samples by designating them in a mixture of nitric acid and perchloric acid. The quantification was made with atomic absorption spectrometry using an air-acetylene flame. The reliability of the procedure used was checked by analysing standard reference materials from NBS and IAEA, such as Rice flour (NBS-SRM-1568), Horse Kidney (IAEA H-8), Mixed Human diet(IAEA H-9), Copepod (IAEA MA-A-1) and fish flesh (IAEA MA-A-2) under identical conditions. A good agreement was observed between determined and the certified values reported by NBS and IAEA. (author)

  19. Design of standard operating procedure production proceses (case study on the home industry Bedugul Baturiti Tabanan Bali)

    Science.gov (United States)

    Kasiani; Suhantono, Djoko; Mirah Kencanawati, AAA

    2018-01-01

    Candikuning is part of the district of Baturiti, tourism village, better known by the name of Bedugul. No less interesting is the variety of chips produced by two partner groups as a souvenir after the tour, such as Chips: Spinach; beans; Tempeh. The purpose of this research were to design a Standard Operating Procedure (SOP): Production Processes on the Home Industry Bedugul Baturiti Tabanan Bali. The data technic collected use: observation; Documentation; and then interview to collect information. The data analysis technic done by using the Miles & Huberman. Result this research that the draft SOP: Production Processes Chips (Menu). The conclusion in this research SOP Production Processes use with flowchart and description on the Home Industry Bedugul Baturiti Tabanan Bali.

  20. 5 CFR 179.309 - Additional administrative procedures.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Additional administrative procedures. 179.309 Section 179.309 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE REGULATIONS CLAIMS COLLECTION STANDARDS Administrative Offset § 179.309 Additional administrative procedures. Nothing...

  1. Large regional differences in incidence of arthroscopic meniscal procedures in the public and private sector in Denmark.

    Science.gov (United States)

    Hare, Kristoffer Borbjerg; Vinther, Jesper Høeg; Lohmander, L Stefan; Thorlund, Jonas Bloch

    2015-02-24

    A recent study reported a large increase in the number of meniscal procedures from 2000 to 2011 in Denmark. We examined the nation-wide distribution of meniscal procedures performed in the private and public sector in Denmark since different incentives may be present and the use of these procedures may differ from region to region. We included data on all patients who underwent an arthroscopic meniscal procedure performed in the public or private sector in Denmark. Data were retrieved from the Danish National Patient Register on patients who underwent arthroscopic meniscus surgery as a primary or secondary procedure in the years 2000 to 2011. Hospital identification codes enabled linkage of performed procedures to specific hospitals. Yearly incidence of meniscal procedures per 100,000 inhabitants was calculated with 95% CIs for public and private procedures for each region. Incidence of meniscal procedures increased at private and at public hospitals. The private sector accounted for the largest relative and absolute increase, rising from an incidence of 1 in 2000 to 98 in 2011. In 2011, the incidence of meniscal procedures was three times higher in the Capital Region than in Region Zealand. Our study identified a large increase in the use of meniscal procedures in the public and private sector in Denmark. The increase was particularly conspicuous in the private sector as its proportion of procedures performed increased from 1% to 32%. Substantial regional differences were present in the incidence and trend over time of meniscal procedures. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. Modified duval procedure for small-duct chronic pancreatitis without head dominance.

    Science.gov (United States)

    Oida, Takatsugu; Aramaki, Osamu; Kano, Hisao; Mimatsu, Kenji; Kawasaki, Atsushi; Kuboi, Youichi; Fukino, Nobutada; Kida, Kazutoshi; Amano, Sadao

    2011-01-01

    In the case of small-duct chronic pancreatitis, surgery for pain relief is broadly divided into resection and drainage procedures. These procedures should be selected according to the location of dominant lesion, diameter of the pancreatic duct and extent of the disease. The appropriate procedure for the treatment of small-duct chronic pancreatitis, especially small-duct chronic pancreatitis without head dominance, remains controversial. We developed the modified Duval procedure for the treatment of small-duct chronic pancreatitis without head dominance and determined the efficacy of this procedure. We retrospectively studied 14 patients who underwent surgical drainage with or without pancreatic resection for chronic pancreatitis with small pancreatic duct (Puestow procedure group and the modified Duval procedure group. No complications occurred in the modified Duval group. In the modified Puestow procedure group, complete and partial pain relief were observed in 62.5%, and 37.5% of patients respectively. In contrast, complete pain relief was observed in all the patients in the modified Duval procedure group. Our modified Duval procedure is useful and should be considered the appropriate surgical technique for the treatment of small-duct chronic pancreatitis without head dominance.

  3. Quality assurance and gastrointestinal endoscopy: an audit of 500 colonoscopic procedures.

    Science.gov (United States)

    Denis, Bernard; Weiss, Anne-Marie; Peter, André; Bottlaender, Jacques; Chiappa, Pascale

    2004-12-01

    The aim of this study was to assess the quality of colonoscopic procedures in our endoscopy unit with the goal of improving performance. We prospectively audited 500 consecutive colonoscopic procedures and assessed sixty-two process or outcome indicators for each procedure. Most of the measured indicators were within standard limits: cecal intubation rate (92%), inadequate bowel preparations (24%), inappropriate procedures (9.7%), normal procedures (54%), yield for neoplasia (32%), morbidity (0.4%), and overall patient satisfaction (95.8%). Some indicators were outside standard limits suggesting our practices should be modified: endoscopy withdrawal time less than 6 minutes (78%), forceps removal of polyps (31%), resected polyps not recovered for pathological examination (12%), adenomas with villous elements (22%), patients unsatisfied because of time spent waiting for the procedure (19%), patients unsatisfied because of inadequate explanations (10%). There was no standard for a few indicators: patient discomfort (6.9%), diagnostic success (89%), therapeutic success (92%). Three new indicators were proposed: proportion of patients agedadvanced adenoma or cancer, and proportion of colonoscopic procedures causing discomfort. The diagnostic yield of colonoscopy was dependent on age, gender, indication and appropriateness of indication but not on the prescriber. This audit allowed us to evaluate our endoscopic practices and to detect certain shortcomings and deviations from standards. It enabled us to change some of our practices with the goal of improving the quality of our colonoscopic procedures.

  4. Comparison of transition-matrix sampling procedures

    DEFF Research Database (Denmark)

    Yevick, D.; Reimer, M.; Tromborg, Bjarne

    2009-01-01

    We compare the accuracy of the multicanonical procedure with that of transition-matrix models of static and dynamic communication system properties incorporating different acceptance rules. We find that for appropriate ranges of the underlying numerical parameters, algorithmically simple yet high...... accurate procedures can be employed in place of the standard multicanonical sampling algorithm....

  5. Safety and effectiveness of a circumferential clip-based vascular closure device for hemostasis in off-label applications: Comparison with standard applications

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Chan; Kim, Chang Won [Dept. of Radiology, Pusan National University School of Medicine, Pusan National University Hospital, Busan (Korea, Republic of); Jeon, Ung Bae [Dept. of Radiology, Pusan National University School of Medicine, Yangsan Pusan National University Hospital, Yangsan (Korea, Republic of)

    2016-09-15

    We investigated the efficacy and safety of a circumferential nitinol clip based arterial closure device following arteriotomy, especially in off-label applications. Consecutive patients who underwent the procedure with arteriotomy from January 2011 to February 2014 were included in this study. We defined standard use as the use of StarClose for retrograde puncture of the common femoral artery (CFA) and off-label use as the use of StarClose for retrograde puncture of the superficial femoral artery (SFA), antegrade puncture of the CFA or SFA, puncture of the brachial artery or puncture of the vascular graft. The procedures performed included percutaneous transluminal angioplasty and thrombolysis. Technical success was defined as complete hemostasis achieved within 3 minute after the closure. Complications, and laboratory findings associated with coagulation function, were also investigated. There were 146 cases of standard applications and 111 cases of off-label applications. Technical success was achieved in all cases. The off-label group comprised the use of StarClose for retrograde puncture of the SFA (n = 19), antegrade puncture of the CFA or SFA (n = 74), brachial artery puncture (n = 5), larger sheath than 6 Fr (n = 7) and vascular graft puncture (n = 6). Minor complications were noted in both groups (standard group: 7.5%, off-label group: 2.7%). Off-label use of StarClose is safe and feasible.

  6. Safety and effectiveness of a circumferential clip-based vascular closure device for hemostasis in off-label applications: Comparison with standard applications

    International Nuclear Information System (INIS)

    Lee, Seung Chan; Kim, Chang Won; Jeon, Ung Bae

    2016-01-01

    We investigated the efficacy and safety of a circumferential nitinol clip based arterial closure device following arteriotomy, especially in off-label applications. Consecutive patients who underwent the procedure with arteriotomy from January 2011 to February 2014 were included in this study. We defined standard use as the use of StarClose for retrograde puncture of the common femoral artery (CFA) and off-label use as the use of StarClose for retrograde puncture of the superficial femoral artery (SFA), antegrade puncture of the CFA or SFA, puncture of the brachial artery or puncture of the vascular graft. The procedures performed included percutaneous transluminal angioplasty and thrombolysis. Technical success was defined as complete hemostasis achieved within 3 minute after the closure. Complications, and laboratory findings associated with coagulation function, were also investigated. There were 146 cases of standard applications and 111 cases of off-label applications. Technical success was achieved in all cases. The off-label group comprised the use of StarClose for retrograde puncture of the SFA (n = 19), antegrade puncture of the CFA or SFA (n = 74), brachial artery puncture (n = 5), larger sheath than 6 Fr (n = 7) and vascular graft puncture (n = 6). Minor complications were noted in both groups (standard group: 7.5%, off-label group: 2.7%). Off-label use of StarClose is safe and feasible

  7. The modified Puestow procedure for complicated hereditary pancreatitis in children.

    Science.gov (United States)

    DuBay, D; Sandler, A; Kimura, K; Bishop, W; Eimen, M; Soper, R

    2000-02-01

    The aim of this study was to evaluate the role of longitudinal pancreaticojejunostomy (modified Puestow procedure) in the treatment of complicated hereditary pancreatitis (HP) in children. The authors reviewed their experience with the modified Puestow procedure for complicated HP in patients less than 18 years of age at a single tertiary care facility between 1973 and 1998. Main study outcomes included surgical morbidity and mortality, pre- and postoperative pancreatic function, number of hospitalizations, and percentile ideal body weight (IBW). Twelve patients (6 boys and 6 girls) with a mean age of 9.3 years were identified. Presenting diagnoses were abdominal pain (n = 10), failure to thrive (n = 4), pancreatic pleural effusion (n = 2), and pancreatic ascites (n = 1). Blood loss was greater in patients who underwent distal pancreatectomy to localize the duct (n = 6) than in those who underwent direct transpancreatic duct localization (n = 6; 29.1+/-6.8 v. 8.3+/-3.7 mL/kg; P = .03). Other complications in patients who underwent distal pancreatectomy included splenic devascularization requiring splenectomy (n = 1) and postoperative intraabdominal bleeding with subsequent left subphrenic abscess (n = 1). There was no surgical mortality. Five patients had steatorrhea preoperatively that resolved in 4 patients postoperatively and was well controlled in the fifth. Mean number of hospitalizations for pancreatitis in the 5 years after surgery were markedly less than in the 5 years preceding surgery (0.4+/-0.2 v. 3.5+/-0.5; P = .01, n = 9). Percentile ideal body weight tended to increase within the first postoperative year (24.6+/-6.8 v. 45.0+/-8.3; P = .07, n = 9), and by the third year this trend was clearly significant (27.0+/-7.2 v. 60.9+/-9.5; P = .01, n = 8). In children with complicated HP, the modified Puestow procedure improves the quality of life by improving pancreatic function, decreasing hospitalizations, and increasing the percentile ideal body weight

  8. Relevant Standards

    Indian Academy of Sciences (India)

    .86: Ethernet over LAPS. Standard in China and India. G.7041: Generic Framing Procedure (GFP). Supports Ethernet as well as other data formats (e.g., Fibre Channel); Protocol of ... IEEE 802.3x for flow control of incoming Ethernet data ...

  9. Chapter 5. Essential equipment, pharmaceuticals and supplies. Recommendations and standard operating procedures for intensive care unit and hospital preparations for an influenza epidemic or mass disaster

    NARCIS (Netherlands)

    Sprung, Charles L.; Kesecioglu, Jozef; Christian, Michael D.; Camargo, Ruben; Ceraso, Daniel; Azoulay, Elie; Duguet, Alexandre; Guery, Benoit; Reinhart, Konrad; Adini, Bruria; Barlavie, Yaron; Benin-Goren, Odeda; Cohen, Robert; Klein, Motti; Leoniv, Yuval; Margalit, Gila; Rubinovitch, Bina; Sonnenblick, Moshe; Steinberg, Avraham; Weissman, Charles; Wolff, Donna; de Jong, Menno; Moreno, Rui; An, Youzhong; Du, Bin; Joynt, Gavin M.; Colvin, John; Loo, Shi; Richards, Guy; Artigas, Antonio; Pugin, Jerome; Amundson, Dennis; Devereaux, Asha; Beigel, John; Danis, Marion; Farmer, Chris; Hick, John L.; Maki, Dennis; Masur, Henry; Rubinson, Lewis; Sandrock, Christian; Talmor, Daniel; Truog, Robert; Zimmerman, Janice; Brett, Steve; Montgomery, Hugh; Rhodes, Andrew; Sanderson, Frances; Taylor, Bruce

    2010-01-01

    To provide recommendations and standard operating procedures for intensive care unit and hospital preparations for an influenza pandemic or mass disaster with a specific focus on essential equipment, pharmaceuticals and supplies. Based on a literature review and expert opinion, a Delphi process was

  10. 47 CFR 22.150 - Standard pre-filing technical coordination procedure.

    Science.gov (United States)

    2010-10-01

    ... this procedure for specific channels and types of stations are contained in the subparts governing the..., emission type and polarization. (4) Transmitting antenna pattern and maximum gain. (5) Transmitting antenna..., even if no channel usage conflicts are anticipated. If any notified party fails to respond within 30...

  11. 21 CFR 60.44 - Hearing procedures.

    Science.gov (United States)

    2010-04-01

    ... RESTORATION Due Diligence Hearings § 60.44 Hearing procedures. The due diligence hearing shall be conducted in accordance with this part, supplemented by the nonconflicting procedures in part 16. During the due diligence... requesting a hearing under part 16. The standard of due diligence set forth in § 60.36 will apply in the due...

  12. All in: expansion of the acquisition of data for outcomes and procedure transfer (ADOPT) program to an entire SAGES annual meeting hands-on hernia course.

    Science.gov (United States)

    Dort, Jonathan; Trickey, Amber; Paige, John; Schwarz, Erin; Cecil, Tom; Coleman, Mark; Dunkin, Brian

    2018-05-01

    Continuing professional development (CPD) for the surgeon has been challenging because of a lack of standardized approaches of hands-on courses, resulting in poor post-course outcomes. To remedy this situation, SAGES has introduced the ADOPT program, implementing a standardized, long-term mentoring program as part of its hernia hands-on course. Previous work evaluating the pilot program showed increased adoption of learned procedures as well as increased confidence of the mentored surgeons. This manuscript describes the impact of such a program when it is instituted across an entire hands-on course. Following collection of pre-course benchmark data, all participants in the 2016 SAGES hands-on hernia course underwent structured, learner-focused instruction during the cadaveric lab. All faculty had completed a standardized teaching course in the Lapco TT format. Subsequently, course participants were enrolled in a year-long program involving longitudinal mentorship, webinars, conference calls, and coaching. Information about participant demographics, training, experience, self-reported case volumes, and confidence levels related to procedures were collected via survey 3 months prior to 9 months after the course. Twenty surgeons participated in the SAGES ADOPT 2016 hands-on hernia program. Of these, seventeen completed pre-course questionnaires (85%), ten completed the 3-month questionnaire (50%), and four completed the 9-month questionnaire (20%). Nine of ten respondents of the 3-month survey (90%) reported changes in their practice. In the 9-month survey, significant increases in the annualized procedural volumes were reported for open primary ventral hernia repair, open components separation, and mesh insertion for ventral hernia repair (p ADOPT program to an entire hands-on hernia course is both feasible and beneficial, with evidence of Kirkpatrick Levels 1-4a training effectiveness. This expanded success suggests that it is a useful blueprint for the CPD of

  13. [A Distal Bile Duct Carcinoma Patient Who Underwent Surgical Resection for Liver Metastasis].

    Science.gov (United States)

    Komiyama, Sosuke; Izumiya, Yasuhito; Kimura, Yu; Nakashima, Shingo; Kin, Syuichi; Kawakami, Sadao

    2018-03-01

    A 70-year-old man with distal bile duct carcinoma underwent a subtotal stomach-preserving pancreaticoduodenectomy without adjuvant chemotherapy. One and a half years after the surgery, elevated levels of serum SPan-1(38.1 U/mL)were observed and CT scans demonstrated a solitary metastasis, 25mm in size, in segment 8 of the liver. The patient received 2 courses of gemcitabine-cisplatin combination chemotherapy. No new lesions were detected after chemotherapy and the patient underwent a partial liver resection of segment 8. The pathological examination revealed a metachronous distant metastasis originating from the bile duct carcinoma. Subsequently, the patient received S-1 adjuvant chemotherapy for 6 months. Following completion of all therapies, the patient survived without tumor recurrence for 3 years and 10 months after the initial operation. Thus, surgical interventions might be effective in improving prognosis among selected patients with postoperative liver metastasis of bile duct carcinoma.

  14. ALGORITHM FOR MANAGEMENT OF HYPERTENSIVE PATIENTS UNDERWENT UROLOGY INTERVENTIONS

    Directory of Open Access Journals (Sweden)

    S. S. Davydova

    2013-01-01

    Full Text Available Aim. To study the efficacy of cardiovascular non-invasive complex assessment and pre-operative preparation in hypertensive patients needed in surgical treatment of urology dis- eases.Material and methods. Males (n=883, aged 40 to 80 years were included into the study. The main group consisted of patients that underwent laparotomic nephrectomy (LTN group; n=96 and patients who underwent laparoscopic nephrectomy (LSN group; n=53. Dynamics of ambulatory blood pressure monitoring (ABPM data was analyzed in these groups in the immediate postoperative period. The efficacy of a package of non-invasive methods for cardiovascular system assessment was studied. ABPM was performed after nephrectomy (2-nd and 10-th days after surgery in patients with complaints of vertigo episodes or intense general weakness to correct treatment.Results. In LTN group hypotension episodes or blood pressure (BP elevations were observed in 20 (20.8% and 22 (22.9% patients, respectively, on the 2-nd day after the operation. These complications required antihypertensive treatment correction. Patients with hypotension episodes were significantly older than patients with BP elevation and had significantly lower levels of 24-hour systolic BP, night diastolic BP and minimal night systolic BP. Re-adjustment of antihypertensive treatment on the 10-th postoperative day was required to 2 (10% patients with hypotension episodes and to 1 (4.5% patient with BP elevation. Correction of antihypertensive therapy was required to all patients in LSN group on the day 2, and to 32 (60.4% patients on the 10-th day after the operation. Reduction in the incidence of complications (from 1.2% in 2009 to 0.3% in 2011, p<0.001 was observed during the application of cardiovascular non-invasive complex assessment and preoperative preparation in hypertensive patients.Conclusion. The elaborated management algorithm for patients with concomitant hypertension is recommended to reduce the cardiovascular

  15. ALGORITHM FOR MANAGEMENT OF HYPERTENSIVE PATIENTS UNDERWENT UROLOGY INTERVENTIONS

    Directory of Open Access Journals (Sweden)

    S. S. Davydova

    2015-09-01

    Full Text Available Aim. To study the efficacy of cardiovascular non-invasive complex assessment and pre-operative preparation in hypertensive patients needed in surgical treatment of urology dis- eases.Material and methods. Males (n=883, aged 40 to 80 years were included into the study. The main group consisted of patients that underwent laparotomic nephrectomy (LTN group; n=96 and patients who underwent laparoscopic nephrectomy (LSN group; n=53. Dynamics of ambulatory blood pressure monitoring (ABPM data was analyzed in these groups in the immediate postoperative period. The efficacy of a package of non-invasive methods for cardiovascular system assessment was studied. ABPM was performed after nephrectomy (2-nd and 10-th days after surgery in patients with complaints of vertigo episodes or intense general weakness to correct treatment.Results. In LTN group hypotension episodes or blood pressure (BP elevations were observed in 20 (20.8% and 22 (22.9% patients, respectively, on the 2-nd day after the operation. These complications required antihypertensive treatment correction. Patients with hypotension episodes were significantly older than patients with BP elevation and had significantly lower levels of 24-hour systolic BP, night diastolic BP and minimal night systolic BP. Re-adjustment of antihypertensive treatment on the 10-th postoperative day was required to 2 (10% patients with hypotension episodes and to 1 (4.5% patient with BP elevation. Correction of antihypertensive therapy was required to all patients in LSN group on the day 2, and to 32 (60.4% patients on the 10-th day after the operation. Reduction in the incidence of complications (from 1.2% in 2009 to 0.3% in 2011, p<0.001 was observed during the application of cardiovascular non-invasive complex assessment and preoperative preparation in hypertensive patients.Conclusion. The elaborated management algorithm for patients with concomitant hypertension is recommended to reduce the cardiovascular

  16. 12 CFR 616.6300 - Leasing policies, procedures, and underwriting standards.

    Science.gov (United States)

    2010-01-01

    ... property and associated risks; (e) Property tax and sales tax reporting; (f) Title and ownership of leased... engaged in lease underwriting must adopt a written policy (or policies). Management, at the direction of the board, must develop procedures that reflect lease practices that control risk and comply with all...

  17. A combined hands-on teaching programme and clinical pathway focused on pleural ultrasound and procedure supervision transforms pleural procedure outcomes.

    Science.gov (United States)

    Edwards, Timothy; Cook, Alistair; Salamonsen, Matthew; Bashirzadeh, Farzad; Fielding, David

    2017-11-01

    Management of pleural effusions is a common diagnostic and management problem. We reviewed the outcomes from pleural procedures after the instigation of pleural effusion management guidelines, focusing on pleural ultrasound and a hands-on teaching programme followed by procedure supervision that enabled many operators to perform such procedures. This is a retrospective analysis of all procedures performed for pleural effusions on medical patients. Outcomes were assessed prior to the instigation of pleural effusion management guidelines (pleural pathway) and hands-on teaching (January 2010 to June 2011) and following these interventions (January 2012 to June 2013). A total of 171 procedures involving 129 patients (pre-pathway group) and 146 procedures involving 115 patients (post-pathway group) was analysed. The rate of complications prior to the pleural pathway was 22.2% (38 of 171 procedures). Following the pathway, the rate of complications declined to 7.5% (11 of 146 procedures, P < 0.003). The use of pleural ultrasound increased dramatically (72.5 vs 90.2%). The number of patients who underwent repeated procedures (defined as ≥3) reduced dramatically (21 vs 7, P < 0.01). This improvement occurred using many supervised operators who completed the hands-on teaching programme (n = 32) and followed the pleural pathway (127 of 146 procedures). The instigation of a clinical pathway focused on the use of bedside pleural ultrasound, and teaching of drainage techniques with procedure supervision vastly improved patient outcomes. This not only allowed better quality of care for patients, it also provided the acquisition of new skills to medical staff, not limiting these skills to specialised staff. © 2017 Royal Australasian College of Physicians.

  18. Prevalence of Endometriosis Among Women Undergoing Laparoscopic Procedures

    Directory of Open Access Journals (Sweden)

    K. K. Chu

    1995-01-01

    Full Text Available We evaluated 752 patients for endometriosis in consecutive laparoscopic procedures over a one year period. Six hundred eighty patients underwent laparoscopy for indications unrelated to symptoms of endometriosis and 72 patients were diagnosed clinically to have endometriosis before the procedures. In the 72 patients with clinical indications of endometriosis, 59 patients had disease confirmed at surgery (82%. Out of 680 asymptomatic patients, 186 patients (24.7% were documented to have the disease of various characteristics or appearances in which the typical lesions accounted for 42%. The overall prevalence among these women undergoing laparoscopy was 32.5%. However, a prevalence of 12% was shown in a subset of asymptomatic patients indicated for sterilization. This may reflect the appropriate prevalence in reproductive age population.

  19. The safety of donor skin preserved with glycerol - Evaluating the Euro Skin Bank preservation procedures of human donor skin against the prEN 12442 standard

    NARCIS (Netherlands)

    Geertsma RE; Wassenaar C; LGM

    2000-01-01

    The procedures for preservation of human donor skin with glycerol, as applied by the Euro Skin Bank (ESB), were evaluated against the prEN 12442 standard: animal tissues and their derivatives used in the manufacture of medical devices. The focus chosen for this review is on risks related to the

  20. Patients' satisfaction with the Nuss procedure

    International Nuclear Information System (INIS)

    Ishimaru, Tetsuya; Iwanaka, Tadashi; Uchida, Hiroo; Kawashima, Hiroshi; Gotoh, Chikashi; Satoh, Kaori; Yoshida, Mariko; Kitano, Yoshihiro

    2009-01-01

    The purpose of this study is to investigate the satisfaction of patients who have already finished bar removal. Fifty-four patients with pectus excavatum underwent the Nuss procedure between July 2000 and December 2007 and the bar was removed in 41 of them at our hospital. A telephone questionnaire was administered to their parents or the patients (12 years old or older). The questions were as follows: self-assessment of the present thoracic form on a 5-point scale, whether it was good to have undergone the Nuss procedure (Y/N), whether the patient will recommend this procedure to another patient (Y/N). Thirty-nine patients responded to the questionnaire. Median age at the bar insertion was 83 months (range: 63-189 months). The bar was removed about 2 years after the initial operation. The median period after removal was 29 months ( range: 2-65 months). The mean point for the thoracic form was 4.2 (5 points: 20, 4 points: 11, 3 points: 5, 2 points: 3). Thirty-eight patients answered that they were satisfied with this procedure. Thirty-four patients answered that they would recommend this procedure to another patient. Eight patients reported that redepression occurred after bar removal. Six of them are under observation because their thoracic deformity is mild. Patients' satisfaction with the Nuss procedure was high. However, our study shows the possibility of post-removal recurrence. There seems to be a tendency for patients to assess their thoracic form more strictly than the doctors. (author)

  1. The tsunami probabilistic risk assessment (PRA). Example of accident sequence analysis of tsunami PRA according to the standard for procedure of tsunami PRA for nuclear power plants

    International Nuclear Information System (INIS)

    Ohara, Norihiro; Hasegawa, Keiko; Kuroiwa, Katsuya

    2013-01-01

    After the Fukushima Daiichi nuclear power plant (NPP) accident, standard for procedure of tsunami PRA for NPP had been established by the Standardization Committee of AESJ. Industry group had been conducting analysis of Tsunami PRA for PWR based on the standard under the cooperation with electric utilities. This article introduced overview of the standard and examples of accident sequence analysis of Tsunami PRA studied by the industry group according to the standard. The standard consisted of (1) investigation of NPP's composition, characteristics and site information, (2) selection of relevant components for Tsunami PRA and initiating events and identification of accident sequence, (3) evaluation of Tsunami hazards, (4) fragility evaluation of building and components and (5) evaluation of accident sequence. Based on the evaluation, countermeasures for further improvement of safety against Tsunami could be identified by the sensitivity analysis. (T. Tanaka)

  2. Comparison between the triglycerides standardization of routine methods used in Japan and the chromotropic acid reference measurement procedure used by the CDC Lipid Standardization Programme.

    Science.gov (United States)

    Nakamura, Masakazu; Iso, Hiroyasu; Kitamura, Akihiko; Imano, Hironori; Noda, Hiroyuki; Kiyama, Masahiko; Sato, Shinichi; Yamagishi, Kazumasa; Nishimura, Kunihiro; Nakai, Michikazu; Vesper, Hubert W; Teramoto, Tamio; Miyamoto, Yoshihiro

    2016-11-01

    Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) -1.292 ( n = 495, R 2  = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was -0.71%, -0.42% and -0.13%, respectively. For the combined precision, the equation y (CV) = -0.398 × (triglycerides value) + 1.797 ( n = 495, R 2  = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time.

  3. Radioimmunoassay procedure using a stabilized complex

    International Nuclear Information System (INIS)

    Sultanian, I.V.; Irani, J.H.

    1978-01-01

    An improved radioimmunoassay procedure involves the use of a stabilized complex of labelled antigen and antibody which has an extended shelf life as compared to the same complex absent the stabilizers. Since the time needed to incubate the mixture of labelled antigen and antibody is eliminated, the time for completing the assay is considerably shortened and simplified. The components for carrying out the procedure are packaged in a kit basically including standard antigen for generation of a standard curve, a stabilized labelled antigen-antibody complex and reference serum, if used. A plurality of stabilizers are used in the complex to provide a shelf life of six weeks or more. 10 claims

  4. Utilization of Body Contouring Procedures Following Weight Loss Surgery: A Study of 37,806 Patients.

    Science.gov (United States)

    Altieri, Maria S; Yang, Jie; Park, Jihye; Novikov, David; Kang, Lijuan; Spaniolas, Konstantinos; Bates, Andrew; Talamini, Mark; Pryor, Aurora

    2017-11-01

    Bariatric surgery has substantial health benefits; however, some patients desire body contouring (BC) procedures following rapid weight loss. There is a paucity of data regarding the true rate of BC following bariatric procedures. The purpose of our study is to examine the utilization of two common procedures, abdominoplasty, and panniculectomy, following bariatric surgery in New York State. The SPARCS longitudinal administrative database was used to identify bariatric procedures by using ICD-9 and CPT codes between 2004 and 2010. Procedures included sleeve gastrectomy, Roux-en-Y gastric bypass, and laparoscopic adjustable gastric banding. Using a unique patient identifier, we tracked those patients who subsequently underwent either abdominoplasty or panniculectomy with at least a 4-year follow-up (until 2014). Multivariable Cox proportional hazard model was used to evaluate predictors of follow-up BC surgery. 37,806 patients underwent bariatric surgery between 2004 and 2010. Only 5.58% (n = 2112) of these patients subsequently had a BC procedure, with 143 of them (6.8%) having ≥1 plastic surgery. The average time to plastic surgery after band, bypass, or sleeve was 1134.83 ± 671.09, 984.70 ± 570.53, and 903.02 ± 497.31 days, respectively (P 80%ile in yearly income were more likely to have plastic surgery after adjusting for age, race/ethnicity, comorbidities and complications (P values plastic surgery is completed by only 6% of patients following bariatric procedures. As insurance and income are associated with pursuing surgery, improved access may increase the number of patients who are able to undergo these reconstructive procedures.

  5. Endovascular treatment outcomes using the Stroke Triage Education, Procedure Standardization, and Technology (STEPS-T) program.

    Science.gov (United States)

    Hassan, Ameer E; Sanchez, Christina; Johnson, Angela N

    2018-02-01

    Background "Door to treatment" time affects outcomes of acute ischemic stroke (AIS) patients undergoing endovascular treatment (EVT). However, the correlation between staff education and accessible technology with stroke outcomes has not been demonstrated. Objective The objective of this paper is to demonstrate the five-year impact of the Stroke Triage Education, Procedure Standardization, and Technology (STEPS-T) program on time-to-treat and clinical outcomes. Methods The study analyzed a prospectively maintained database of AIS patients who benefited from EVT through implementation of STEPS-T. Demographics, clinical characteristics, and modified Rankin Score at three months were analyzed. Thrombolysis in Cerebral Infarction (TICI) scale was used to grade pre- and post-procedure angiographic recanalization. Using electronic hemodynamic recording, stepwise workflow times were collected for door time (T D ), entering angiography suite (T A ), groin puncture (T G ), first DSA (T DSA ), microcatheter placement (T M ), and final recanalization (T R ). Median intervention time (T A to T R ) and recanalization time (T G to T R ) were compared through Year 1 to Year 5. Results A total of 230 individuals (age 74 ± 12, between 30 to 95) were enrolled. Median intervention and recanalization times were significantly reduced, from 121 minutes to 52 minutes and from 83 minutes to 36 minutes respectively from Year 1 to Year 5, ( p < 0.001). Across the study period, annual recruitment went up from 12 to 66 patients, and modified Rankin Score between 0 and 2 increased from 36% to 59% ( p = 0.024). Conclusions STEPS-T improved time-to-treat in patients undergoing mechanical thrombectomy for AIS. During the observation period, clinical outcomes significantly improved.

  6. Music Therapy as Procedural Support for Young Children Undergoing Immunizations: A Randomized Controlled Study.

    Science.gov (United States)

    Yinger, Olivia Swedberg

    2016-01-01

    Children undergoing routine immunizations frequently experience severe distress, which may be improved through music therapy as procedural support. The purpose of this study was to examine effects of live, cognitive-behavioral music therapy during immunizations on (a) the behaviors of children, their parents, and their nurses; and (b) parental perceptions. Participants were children between the ages of 4 and 6 years (N = 58) who underwent immunizations, their parents (N = 62), and the nurses who administered the procedure (N = 19). Parent/child dyads were randomly assigned to receive music therapy (n = 29) or standard care (n = 29) during their immunization. Afterward, each parent rated their child's level of pain and the distress their child experienced compared to previous medical experiences. All procedures were videotaped and later viewed by trained observers, who classified child, parent, and nurse behaviors using the categories of the Child-Adult Medical Procedure Interaction Scale-Revised (CAMPIS-R). Significant differences between the music therapy and control groups were found in rates of child coping and distress behaviors and parent distress-promoting behaviors. Parents of children who received music therapy reported that their child's level of distress was less than during previous medical experiences, whereas parents of children in the control group reported that their child's level of distress was greater. No significant differences between groups were found in parents' ratings of children's pain or in rates of nurse behavior. Live, cognitive-behavioral music therapy has potential benefits for young children and their parents during immunizations. © the American Music Therapy Association 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Inducing changes in arousal and valence: comparison of two mood induction procedures.

    Science.gov (United States)

    Jallais, Christophe; Gilet, Anne-Laure

    2010-02-01

    This research examined the relative effectiveness of two mood induction procedures (MIPs) for inducing four specific moods varying along the dimensions of both valence and arousal. Participants were randomly assigned either to an autobiographical recall or to a music and guided imagery MIP and underwent a happiness, serenity, anger, or sadness mood induction. The findings confirmed the effectiveness of the two MIPs in producing changes on both the valence and arousal dimensions of mood. The results also revealed an unexpected greater efficiency of the autobiographical recall than of the combined procedure.

  8. Environmental radiation protection standards

    International Nuclear Information System (INIS)

    Richings, L.D.G.; Morley, F.; Kelley, G.N.

    1978-04-01

    The principles involved in the setting of radiological protection standards are reviewed, and the differences in procedures used by various countries in implementing them are outlined. Standards are taken here to mean the specific numerical limits relating to radiation doses to people or to amounts of radioactive material released into the environment. (author)

  9. Antimicrobial Testing Methods & Procedures Developed by EPA's Microbiology Laboratory

    Science.gov (United States)

    We develop antimicrobial testing methods and standard operating procedures to measure the effectiveness of hard surface disinfectants against a variety of microorganisms. Find methods and procedures for antimicrobial testing.

  10. Calibration of photon and beta ray sources used in brachytherapy. Guidelines on standardized procedures at Secondary Standards Dosimetry Laboratories

    International Nuclear Information System (INIS)

    2004-03-01

    It has generally been recognized that international harmonization in radiotherapy dosimetry is essential. Consequently, the IAEA has given much effort to this, for example by publishing a number of reports in the Technical Reports Series (TRS) for external beam dosimetry, most notably TRS-277 and more recently TRS-398. Both of these reports describe in detail the steps to be taken for absorbed dose determination in water and they are often referred to as 'dosimetry protocols'. Similar to TRS-277, it is expected that TRS-398 will be adopted or used as a model by a large number of countries as their national protocol. In 1996, the IAEA established a calibration service for low dose rate (LDR) 137 Cs brachytherapy sources, which is the most widely used source for treatment of gynecological cancer. To further enhance harmonization in brachytherapy dosimetry, the IAEA published in 1999 IAEA-TECDOC-1079 entitled 'Calibration of Brachytherapy Sources. Guidelines on Standardized Procedures for the Calibration of Brachytherapy Sources at Secondary Standard Dosimetry Laboratories (SSDLs) and Hospitals'. The report was well received and was distributed in a large number of copies to the members of the IAEA/WHO network of SSDLs and to medical physicists working with brachytherapy. The present report is an update of the aforementioned TECDOC. Whereas TECDOC-1079 described methods for calibrating brachytherapy sources with photon energies at or above those of 192 Ir, the current report has a wider scope in that it deals with standardization of calibration of all the most commonly used brachytherapy sources, including both photon and beta emitting sources. The latter sources have been in use for a few decades already, but their calibration methods have been unclear. Methods are also described for calibrating sources used in the rapidly growing field of cardiovascular angioplasty. In this application, irradiation of the vessel wall is done in an attempt to prevent restenosis after

  11. Aesthetic Surgical Procedures in Men: Major Complications and Associated Risk Factors.

    Science.gov (United States)

    Kaoutzanis, Christodoulos; Winocour, Julian; Yeslev, Max; Gupta, Varun; Asokan, Ishan; Roostaeian, Jason; Grotting, James C; Higdon, K Kye

    2018-03-14

    The number of men undergoing cosmetic surgery is increasing in North America. To determine the incidence and risk factors of major complications in males undergoing cosmetic surgery, compare the complication profiles between men and women, and identify specific procedures that are associated with higher risk of complications in males. A prospective cohort of patients undergoing cosmetic surgery between 2008 and 2013 was identified from the CosmetAssure database. Gender specific procedures were excluded. Primary outcome was occurrence of a major complication in males requiring emergency room visit, hospital admission, or reoperation within 30 days of the index operation. Univariate and multivariate analysis evaluated potential risk factors for major complications including age, body mass index (BMI), smoking, diabetes, type of surgical facility, type of procedure, and combined procedures. Of the 129,007 patients, 54,927 underwent gender nonspecific procedures, of which 5801 (10.6%) were males. Women showed a higher mean age (46.4 ± 14.1 vs 45.2 ± 16.7 years, P procedures (RR 3.47), and combined procedures (RR 2.56). Aesthetic surgery in men is safe with low major complication rates. Modifiable predictors of complications included BMI and combined procedures.

  12. 75 FR 63255 - Air Traffic Procedures Advisory Committee Meeting

    Science.gov (United States)

    2010-10-14

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  13. Dysphagia among Adult Patients who Underwent Surgery for Esophageal Atresia at Birth

    Directory of Open Access Journals (Sweden)

    Valérie Huynh-Trudeau

    2015-01-01

    Full Text Available BACKGROUND: Clinical experiences of adults who underwent surgery for esophageal atresia at birth is limited. There is some evidence that suggests considerable long-term morbidity, partly because of dysphagia, which has been reported in up to 85% of adult patients who undergo surgery for esophageal atresia. The authors hypothesized that dysphagia in this population is caused by dysmotility and/or anatomical anomalies.

  14. Chapter 3. Coordination and collaboration with interface units. Recommendations and standard operating procedures for intensive care unit and hospital preparations for an influenza epidemic or mass disaster

    NARCIS (Netherlands)

    Joynt, Gavin M.; Loo, Shi; Taylor, Bruce L.; Margalit, Gila; Christian, Michael D.; Sandrock, Christian; Danis, Marion; Leoniv, Yuval; Sprung, Charles L.; Camargo, Ruben; Ceraso, Daniel; Azoulay, Elie; Duguet, Alexandre; Guery, Benoit; Reinhart, Konrad; Adini, Bruria; Barlavie, Yaron; Benin-Goren, Odeda; Cohen, Robert; Klein, Motti; Rubinovitch, Bina; Sonnenblick, Moshe; Steinberg, Avraham; Weissman, Charles; Wolff, Donna; Kesecioglu, Jozef; de Jong, Menno; Moreno, Rui; An, Youzhong; Du, Bin; Joyng, Gavin M.; Colvin, John; Richards, Guy; Artigas, Antonio; Pugin, Jerome; Amundson, Dennis; Devereaux, Asha; Beigel, John; Farmer, Chris; Hick, John L.; Maki, Dennis; Masur, Henry; Rubinson, Lewis; Talmor, Daniel; Truog, Robert; Zimmerman, Janice; Brett, Steve; Montgomery, Hugh; Rhodes, Andrew; Sanderson, Frances

    2010-01-01

    To provide recommendations and standard operating procedures (SOPs) for intensive care unit (ICU) and hospital preparations for an influenza pandemic or mass disaster with a specific focus on enhancing coordination and collaboration between the ICU and other key stakeholders. Based on a literature

  15. Standardized physics-dosimetry for US pressure vessel cavity surveillance programs

    International Nuclear Information System (INIS)

    Ruddy, F.H.; McElroy, W.N.; Lippincott, E.P.

    1984-01-01

    Standardized Physics-Dosimetry procedures and data are being developed and tested for monitoring the neutron doses accumulated by reactor pressure vessels (PV) and their support structures. These procedures and data are governed by a set of 21 ASTM standard practices, guides, and methods for the prediction of neutron-induced changes in light water reactor (LWR) PVs and support structure steels throughout the service life of the PV. This paper summarizes the applications of these standards to define the selection and deployment of recommended dosimetry sets, the selection of dosimetry capsules and thermal neutron shields, the placement of dosimetry, the methods of measurement of dosimetry sensor reaction products, data analysis procedures, and uncertainty evaluation procedures. It also describes the validation of these standards both by in-reactor testing of advanced PV cavity surveillance physics-dosimetry and by data development. The use of these standards to guide selection and deployment of advanced dosimetry sets for commercial reactors is also summarized

  16. Radiation exposures to technologists from nuclear medicine imaging procedures

    International Nuclear Information System (INIS)

    Sloboda, R.S.; Schmid, M.G.; Willis, C.P.

    1986-05-01

    Radiation exposures incurred by nuclear medicine technologists during diagnostic imaging and gamma camera quality control (QC) were measured on a procedural basis over a three-month period using a portable, low-range, self-reading ion chamber. A total of more than 400 measurements were made for 15 selected procedures. From these, mean procedural exposures and standard deviations were calculated. The results show that daily flood phantom QC, at 0.58 mR, and gated cardiac studies, at 0.45 mR, were the two greatest sources of exposure. Other procedures resulted in exposures varying roughly from 0.10 to 0.20 mR. Difficult patients were responsible for a doubling of technologist exposure for many procedures. Standard deviations were large for all procedures, averaging 65% of the mean values. Comparison of technologist exposure inferred from the procedural measurements with the time coincident collective dose equivalent recorded by the TLD service of the Radiation Protection Bureau indicates that approximately half of the collective technologist exposure arose from patient handling and flood QC

  17. One-Stage Gender-Confirmation Surgery as a Viable Surgical Procedure for Female-to-Male Transsexuals.

    Science.gov (United States)

    Stojanovic, Borko; Bizic, Marta; Bencic, Marko; Kojovic, Vladimir; Majstorovic, Marko; Jeftovic, Milos; Stanojevic, Dusan; Djordjevic, Miroslav L

    2017-05-01

    Female-to-male gender-confirmation surgery (GCS) includes removal of breasts and female genitalia and complete genital and urethral reconstruction. With a multidisciplinary approach, these procedures can be performed in one stage, avoiding multistage operations. To present our results of one-stage sex-reassignment surgery in female-to-male transsexuals and to emphasize the advantages of single-stage over multistage surgery. During a period of 9 years (2007-2016), 473 patients (mean age = 31.5 years) underwent metoidioplasty. Of these, 137 (29%) underwent simultaneous hysterectomy, and 79 (16.7%) underwent one-stage GCS consisting of chest masculinization, total transvaginal hysterectomy with bilateral adnexectomy, vaginectomy, metoidioplasty, urethral lengthening, scrotoplasty, and implantation of bilateral testicular prostheses. All surgeries were performed simultaneously by teams of experienced gynecologic and gender surgeons. Primary outcome measurements were surgical time, length of hospital stay, and complication and reoperation rates compared with other published data and in relation to the number of stages needed to complete GCS. Mean follow-up was 44 months (range = 10-92). Mean surgery time was 270 minutes (range = 215-325). Postoperative hospital stay was 3 to 6 days (mean = 4). Complications occurred in 20 patients (25.3%). Six patients (7.6%) had complications related to mastectomy, and one patient underwent revision surgery because of a breast hematoma. Two patients underwent conversion of transvaginal hysterectomy to an abdominal approach, and subcutaneous perineal cyst, as a consequence of colpocleisis, occurred in nine patients. There were eight complications (10%) from urethroplasty, including four fistulas, three strictures, and one diverticulum. Testicular implant rejection occurred in two patients and testicular implant displacement occurred in one patient. Female-to-male transsexuals can undergo complete GCS, including mastectomy

  18. 50 CFR 82.3 - Supplementary information and procedures.

    Science.gov (United States)

    2010-10-01

    ... INTERIOR (CONTINUED) FINANCIAL ASSISTANCE-WILDLIFE SPORT FISH RESTORATION PROGRAM ADMINISTRATIVE PROCEDURES... governments these regulations are intended to implement and be read as consistent with Federal Management... standards and procedures set forth therein, and other referenced Federal management circulars, will, to the...

  19. Comparison of standard laparoscopic distal pancreatectomy with minimally invasive distal pancreatectomy using the da Vinci S system.

    Science.gov (United States)

    Ito, Masahiro; Asano, Yukio; Shimizu, Tomohiro; Uyama, Ichiro; Horiguchi, Akihiko

    2014-01-01

    Minimally invasive procedures for pancreatic pathologies are increasingly being used, including distal pancreatectomy. This study aimed to assess the indications for and outcomes of the da Vinci distal pancreatectomy procedure. We reviewed the medical records of patients who underwent pancreatic head resection from April 2009 to September 2013. Four patients (mean age, 52.7 years) underwent da Vinci distal pancreatectomy and 10 (mean age, 68.0 +/- 12.1 years) underwent laparoscopic distal pancreatectomy. The mean surgical duration was 292 +/- 153 min and 306 +/- 29 min, the mean blood loss was 153 +/- 71 mL and 61.7 +/- 72 mL, and the mean postoperative length of stay was 24 +/- 11 days and 14 +/- 3 days in the da Vinci distal pancreatectomy and laparoscopic distal pancreatectomy groups, respectively. One patient who underwent da Vinci distal pancreatectomy developed a pancreatic fistula, while 2 patients in the laparoscopic distal pancreatectomy group developed splenic ischemia and gastric torsion, respectively. Laparoscopic and robotic pancreatic resection were both safe and feasible in selected patients with distal pancreatic pathologies. Further studies are necessary to clarify the role of robotic surgery in the advanced laparoscopic era.

  20. Impact of Polypharmacy on Adherence to Evidence-Based Medication in Patients who Underwent Percutaneous Coronary Intervention.

    Science.gov (United States)

    Mohammed, Shaban; Arabi, Abdulrahaman; El-Menyar, Ayman; Abdulkarim, Sabir; AlJundi, Amer; Alqahtani, Awad; Arafa, Salah; Al Suwaidi, Jassim

    2016-01-01

    The primary objective of this study was to evaluate the impact of polypharmacy on primary and secondary adherence to evidence-based medication (EBM) and to measure factors associated with non-adherence among patients who underwent percutaneous coronary intervention (PCI). We conducted a retrospective analysis for patients who underwent PCI at a tertiary cardiac care hospital in Qatar. Patients who had polypharmacy (defined as ≥6 medications) were compared with those who had no polypharmacy at hospital discharge in terms of primary and secondary adherence to dual antiplatelet therapy (DAPT), beta-blockers (BB), angiotensin converting enzyme inhibitors (ACEIs) and statins. A total of 557 patients (mean age: 53±10 years; 85%; males) who underwent PCI were included. The majority of patients (84.6%) received ≥6 medications (polypharmacy group) while only 15.4% patients received ≥5 medications (nonpolypharmacy group). The two groups were comparable in term of gender, nationality, socioeconomic status and medical insurance. The non-polypharmacy patients had significantly higher adherence to first refill of DAPT compared with patients in the polypharmacy group (100 vs. 76.9%; p=0.001). Similarly, the non-polypharmacy patients were significantly more adherent to secondary preventive medications (BB, ACEI and statins) than the polypharmacy group. In patients who underwent PCI, polypharmacy at discharge could play a negative role in the adherence to the first refill of EBM. Further studies should investigate other parameters that contribute to long term non-adherence.

  1. 77 FR 67862 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2012-11-14

    ...The FAA is issuing this notice to advise the public that the FAA's Air Traffic Procedures Advisory Committee (ATPAC) two year charter has been coordinated and signed by the FAA Administrator. The ATPAC charter is valid for two years and provides a venue to review air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures.

  2. 77 FR 27835 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2012-05-11

    ...The FAA is issuing this notice to advise the public that a meeting of the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC) will be held to review present air traffic control procedures and practices for standardization, revision, clarification, and upgrading of terminology and procedures. Class B airspace will be a major topic of discussion on the ATPAC Agenda.

  3. 21 CFR 861.20 - Summary of standards development process.

    Science.gov (United States)

    2010-04-01

    ... accordance with section 513(e) of the act to reclassify the device; or (3) Take other appropriate action. [57... (CONTINUED) MEDICAL DEVICES PROCEDURES FOR PERFORMANCE STANDARDS DEVELOPMENT Procedures for Performance... which a performance standard for a device may be established, amended, or revoked is as follows: (a) The...

  4. Measuring variability of procedure progression in proceduralized scenarios

    International Nuclear Information System (INIS)

    Kim, Yochan; Park, Jinkyun; Jung, Wondea

    2012-01-01

    Highlights: ► The VPP measure was developed to quantify how differently operators follow the procedures. ► Sources that cause variability of ways to follow a given procedure were identified. ► The VPP values for the scenarios are positively related to the scenario performance time. ► The VPP measure is meaningful for explaining characteristics of several PSFs. -- Abstract: Various performance shaping factors (PSFs) have been presented to explain the contributors to unsafe acts in a human failure event or predict a human error probability of new human performance. However, because most of these parameters of an HRA depend on the subjective knowledge and experience of HRA analyzers, the results of an HRA insufficiently provide unbiased standards to explain human performance variations or compare collected data with other data from different analyzers. To secure the validity of the HRA results, we propose a quantitative measure, which represents the variability of procedure progression (VPP) in proceduralized scenarios. A VPP measure shows how differently the operators follow the steps of the procedures. This paper introduces the sources of the VPP measure and relevance to PSFs. The assessment method of the VPP measure is also proposed, and the application examples are shown with a comparison of the performance time. Although more empirical studies should be conducted to reveal the relationship between the VPP measure and other PSFs, it is believed that the VPP measure provides evidence to quantitatively evaluate human performance variations and to cross-culturally compare the collected data.

  5. General and acute care surgical procedures in patients with left ventricular assist devices.

    Science.gov (United States)

    Arnaoutakis, George J; Bittle, Gregory J; Allen, Jeremiah G; Weiss, Eric S; Alejo, Jennifer; Baumgartner, William A; Shah, Ashish S; Wolfgang, Christopher L; Efron, David T; Conte, John V

    2014-04-01

    Left ventricular assist devices (LVADs) have become common as a bridge to heart transplant as well as destination therapy. Acute care surgical (ACS) problems in this population are prevalent but remain ill-defined. Therefore, we reviewed our experience with ACS interventions in LVAD patients. A total of 173 patients who received HeartMate(®) XVE or HeartMate(®) II (HMII) LVADs between December 2001 and March 2010 were studied. Patient demographics, presentation of ACS problem, operative intervention, co-morbidities, transplantation, complications, and survival were analyzed. A total of 47 (27 %) patients underwent 67 ACS procedures at a median of 38 days after device implant (interquartile range 15-110), with a peri-operative mortality rate of 5 % (N = 3). Demographics, device type, and acuity were comparable between the ACS and non-ACS groups. A total of 21 ACS procedures were performed emergently, eight were urgent, and 38 were elective. Of 29 urgent and emergent procedures, 28 were for abdominal pathology. In eight patients, the cause of the ACS problem was related to LVADs or anticoagulation. Cumulative survival estimates revealed no survival differences if patients underwent ACS procedures (p = 0.17). Among HMII patients, transplantation rates were unaffected by an ACS intervention (p = 0.2). ACS problems occur frequently in LVAD patients and are not associated with adverse outcomes in HMII patients. The acute care surgeon is an integral member of a comprehensive approach to effective LVAD management.

  6. Variation in radiation doses in paediatric cardiac catheterisation procedures

    International Nuclear Information System (INIS)

    Al-Haj, A. N.; Lobriguito, A. M.; Rafeh, W.

    2008-01-01

    Paediatric cardiac catheterisation involves diagnostic and therapeutic procedures that range from simple to complex and can subject paediatric patients to varying radiation doses. The study aims to determine the variation in entrance doses in patients in terms of dose-area product (DAP) values and to investigate the methods for optimising radiation protection. A total of 190 paediatric patients belonging to age groups 0, 1, 5 and 10 y who underwent diagnostic and six selected therapeutic procedures at King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia) were included in the study. Therapeutic procedures include coarctation (COA), patent ductus arteriosus (PDA), radiofrequency ablation, pulmonary, embolisation and septostomy. Fluoroscopy and cine radiography were used in all procedures. Patient demography (weight, age, gender and height), radiographic technique factors, fluoroscopy and cine time, frame rate, and DAP values were taken from patients records. Effective doses for each procedure were estimated from the DAP values. The mean DAP per procedure were analysed for correlation with patient equivalent cylindrical diameter, weight, fluoroscopy time and number of frames. Factors influencing the variation in doses were investigated. Initial results show that PDA occlusion has the highest mean DAP value of 23.21 Gy-cm 2 , while the diagnostic and septostomy procedures have the lowest value of 7.77 and 6.95 Gy-cm 2 , respectively. (authors)

  7. Applications of phosphorus/silicon standards in quantitative autoradiography

    International Nuclear Information System (INIS)

    Treutler, H.Ch.; Freyer, K.

    1983-01-01

    Quantitative autoradiography requires a careful selection of suitable standard preparations. After several basic comments related to the problems of standardization in autoradiography an example is given of the autoradiographic study of semiconductor materials and it is used for describing the system of standardization using silicon discs with diffused phosphorus. These standardized samples are processed in the same manner as the evaluated samples, i.e., from activation to exposure to sensitive material whereby optimal comparability is obtained. All failures of the processing cycle caused by the fluctuation of the neutron flux in the reactor, deviations at the time of activation, afterglow, etc. are eliminated by this standardization procedure. Experience is presented obtained with the application of this procedure. (author)

  8. Standard Operating Procedures for Preparing and Handling Sterile Male Tsetse flies for Release

    International Nuclear Information System (INIS)

    Argiles-Herrero, Rafa; Leak, Stephen G.A.

    2016-01-01

    The purpose of this SOP is to describe the procedures involved in preparing tsetse flies reared in a breeding facility for release in the field for the sterile insect technique (SIT) as a component of Area-Wide Insect pest Management (AW-IPM). Following the procedures which are outlined will help to ensure that the released sterile male tsetse flies are of optimal quality.

  9. Beyond the standard model; Au-dela du modele standard

    Energy Technology Data Exchange (ETDEWEB)

    Cuypers, F. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-05-01

    These lecture notes are intended as a pedagogical introduction to several popular extensions of the standard model of strong and electroweak interactions. The topics include the Higgs sector, the left-right symmetric model, grand unification and supersymmetry. Phenomenological consequences and search procedures are emphasized. (author) figs., tabs., 18 refs.

  10. Adequate procedures for specific exams

    International Nuclear Information System (INIS)

    Staevie, G.L.G.; Gattringer, D.K.; Dal Mas, C.R.; Tessman, M.

    1996-01-01

    Some ideal procedures for specific radiographic exams are briefly presented. The aim is to improve the quality standard, establishing a specific method for each exam in order to decrease films waste and reduce the patient dose exposure

  11. Implementation of standards for individual monitoring in Europe

    International Nuclear Information System (INIS)

    Fantuzzi, E.; Alves, J. G.; Ambrosi, P.; Janzekovic, H.; Vartiainen, E.

    2004-01-01

    A large number of standards are available for radiation protection and individual monitoring purposes. They are published by various organisations, international and national. Moreover, the increasing policy of 'Quality' applied to individual monitoring requires the implementation of standards on Quality Assurance (QA) both in technical and management aspects of a dosimetric service. Implementation of standards is not mandatory; therefore, varying degrees of implementation can be found in different European countries. However, for a number of good reasons, a degree of harmonisation within the European Union (EU) of the requirements and procedures for individual monitoring would be desirable. Harmonisation as applied to dosimetric services does not mean that they should all follow exactly the same procedures, but that they should aim to meet the same general requirements, and their results should be comparable. This article aims to compile information on the use of all standards applied within individual monitoring practices, be it on the calibration of dosemeters or on the QA procedures to be applied to the overall dose evaluation process. Both 'technical standards' and 'quality standards' will be discussed. A list of documents of relevance to subjects such as recommendations and requirements in the field of individual monitoring, whose application could help in the harmonisation of procedures, will also be given. As it is agreed that implementation of quality standards is a relevant framework within which harmonisation can be achieved, guidance on the implementation of quality standards in a dosimetric service is given. Accreditation and approval of dosimetric services will be of relevance in the process of harmonisation of individual monitoring within the EU. In this article, a discussion of various procedures and the meaning of both forms of recognition is also provided. Although most of the text applies to the monitoring of internal and external exposure to

  12. Oral Surgical Procedures Performed Safely in Patients With Head and Neck Arteriovenous Malformations: A Retrospective Case Series of 12 Patients.

    Science.gov (United States)

    Karim, Abdul Basit; Lindsey, Sean; Bovino, Brian; Berenstein, Alejandro

    2016-02-01

    This case series describes patients with head and neck arteriovenous malformations who underwent oral and maxillofacial surgical procedures combined with interventional radiology techniques to minimize blood loss. Twelve patients underwent femoral cerebral angiography to visualize the extent of vascular malformation. Before the surgical procedures, surgical sites were devascularized by direct injection of hemostatic or embolic agents. Direct puncture sclerotherapy at the base of surgical sites was performed using Surgiflo or n-butylcyanoacrylate glue. Surgical procedures were carried out in routine fashion. A hemostatic packing of FloSeal, Gelfoam, and Avitene was adapted to the surgical sites. Direct puncture sclerotherapy with Surgiflo or n-butylcyanoacrylate glue resulted in minimal blood loss intraoperatively. Local application of the FloSeal, Gelfoam, and Avitene packing sustained hemostasis and produced excellent healing postoperatively. Patients with arteriovenous malformations can safely undergo routine oral and maxillofacial surgical procedures with minimal blood loss when appropriate endovascular techniques and local hemostatic measures are used by the interventional radiologist and oral and maxillofacial surgeon. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Sutureless versus Conventional Aortic Valve Replacement: Outcomes in 70 High-Risk Patients Undergoing Concomitant Cardiac Procedures.

    Science.gov (United States)

    Hanedan, Muhammet Onur; Yuruk, Mehmet Ali; Parlar, Ali Ihsan; Ziyrek, Ugur; Arslan, Ali Kemal; Sayar, Ufuk; Mataraci, Ilker

    2018-02-01

    In elderly, high-risk surgical patients, sutureless aortic valve replacement (AVR) can often be an alternative to conventional AVR; shorter aortic cross-clamp and cardiopulmonary bypass times are the chief advantages. We compared the outcomes of sutureless AVR with those of conventional AVR in 70 elderly patients who underwent concomitant cardiac surgical procedures. We retrospectively analyzed the cases of 42 men and 28 women (mean age, 70.4 ± 10.3 yr; range, 34-93 yr) who underwent cardiac operations plus AVR with either a sutureless valve (group 1, n=38) or a conventional bioprosthetic or mechanical valve (group 2, n=32). Baseline patient characteristics were similar except for worse New York Heart Association functional status and the prevalence of diabetes mellitus in group 1. In group 1, the operative, cross-clamp, and cardiopulmonary bypass times were shorter (all P =0.001), postoperative drainage amounts were lower ( P =0.009), hospital stays were shorter ( P =0.004), and less red blood cell transfusion was needed ( P =0.037). Echocardiograms before patients' discharge from the hospital showed lower peak and mean aortic gradients in group 1 (mean transvalvular gradient, 8.4 ± 2.8 vs 12.2 ± 5.2 mmHg; P =0.012). We found that elderly, high-risk patients who underwent multiple cardiac surgical procedures and sutureless AVR had better hemodynamic outcomes and shorter ischemic times than did patients who underwent conventional AVR.

  14. Curative procedures of oral health and structural characteristics of primary dental care.

    Science.gov (United States)

    Baumgarten, Alexandre; Hugo, Fernando Neves; Bulgarelli, Alexandre Fávero; Hilgert, Juliana Balbinot

    2018-04-09

    To evaluate if the provision of clinical dental care, by means of the main curative procedures recommended in Primary Health Care, is associated with team structural characteristics, considering the presence of a minimum set of equipment, instrument, and supplies in Brazil's primary health care services. A cross-sectional exploratory study based on data collected from 18,114 primary healthcare services with dental health teams in Brazil, in 2014. The outcome was created from the confirmation of five clinical procedures performed by the dentist, accounting for the presence of minimum equipment, instrument, and supplies to carry them out. Covariables were related to structural characteristics. Poisson regression with robust variance was used to obtain crude and adjusted prevalence ratios, with 95% confidence intervals. A total of 1,190 (6.5%) dental health teams did not present the minimum equipment to provide clinical dental care and only 2,498 (14.8%) had all the instrument and supplies needed and provided the five curative procedures assessed. There was a positive association between the outcome and the composition of dental health teams, higher workload, performing analysis of health condition, and monitoring of oral health indicators. Additionally, the dental health teams that planned and programmed oral health actions with the primary care team monthly provided the procedures more frequently. Dentists with better employment status, career plans, graduation in public health or those who underwent permanent education activities provided the procedures more frequently. A relevant number of Primary Health Care services did not have the infrastructure to provide clinical dental care. However, better results were found in dental health teams with oral health technicians, with higher workload and that plan their activities, as well as in those that employed dentists with better working relationships, who had dentists with degrees in public health and who underwent

  15. Curative procedures of oral health and structural characteristics of primary dental care

    Directory of Open Access Journals (Sweden)

    Alexandre Baumgarten

    2018-04-01

    Full Text Available ABSTRACT OBJECTIVE To evaluate if the provision of clinical dental care, by means of the main curative procedures recommended in Primary Health Care, is associated with team structural characteristics, considering the presence of a minimum set of equipment, instrument, and supplies in Brazil’s primary health care services. METHODS A cross-sectional exploratory study based on data collected from 18,114 primary healthcare services with dental health teams in Brazil, in 2014. The outcome was created from the confirmation of five clinical procedures performed by the dentist, accounting for the presence of minimum equipment, instrument, and supplies to carry them out. Covariables were related to structural characteristics. Poisson regression with robust variance was used to obtain crude and adjusted prevalence ratios, with 95% confidence intervals. RESULTS A total of 1,190 (6.5% dental health teams did not present the minimum equipment to provide clinical dental care and only 2,498 (14.8% had all the instrument and supplies needed and provided the five curative procedures assessed. There was a positive association between the outcome and the composition of dental health teams, higher workload, performing analysis of health condition, and monitoring of oral health indicators. Additionally, the dental health teams that planned and programmed oral health actions with the primary care team monthly provided the procedures more frequently. Dentists with better employment status, career plans, graduation in public health or those who underwent permanent education activities provided the procedures more frequently. CONCLUSIONS A relevant number of Primary Health Care services did not have the infrastructure to provide clinical dental care. However, better results were found in dental health teams with oral health technicians, with higher workload and that plan their activities, as well as in those that employed dentists with better working relationships

  16. Curative procedures of oral health and structural characteristics of primary dental care

    Science.gov (United States)

    Baumgarten, Alexandre; Hugo, Fernando Neves; Bulgarelli, Alexandre Fávero; Hilgert, Juliana Balbinot

    2018-01-01

    ABSTRACT OBJECTIVE To evaluate if the provision of clinical dental care, by means of the main curative procedures recommended in Primary Health Care, is associated with team structural characteristics, considering the presence of a minimum set of equipment, instrument, and supplies in Brazil’s primary health care services. METHODS A cross-sectional exploratory study based on data collected from 18,114 primary healthcare services with dental health teams in Brazil, in 2014. The outcome was created from the confirmation of five clinical procedures performed by the dentist, accounting for the presence of minimum equipment, instrument, and supplies to carry them out. Covariables were related to structural characteristics. Poisson regression with robust variance was used to obtain crude and adjusted prevalence ratios, with 95% confidence intervals. RESULTS A total of 1,190 (6.5%) dental health teams did not present the minimum equipment to provide clinical dental care and only 2,498 (14.8%) had all the instrument and supplies needed and provided the five curative procedures assessed. There was a positive association between the outcome and the composition of dental health teams, higher workload, performing analysis of health condition, and monitoring of oral health indicators. Additionally, the dental health teams that planned and programmed oral health actions with the primary care team monthly provided the procedures more frequently. Dentists with better employment status, career plans, graduation in public health or those who underwent permanent education activities provided the procedures more frequently. CONCLUSIONS A relevant number of Primary Health Care services did not have the infrastructure to provide clinical dental care. However, better results were found in dental health teams with oral health technicians, with higher workload and that plan their activities, as well as in those that employed dentists with better working relationships, who had dentists

  17. Interim radiological safety standards and evaluation procedures for subseabed high-level waste disposal

    International Nuclear Information System (INIS)

    Klett, R.D.

    1997-06-01

    The Seabed Disposal Project (SDP) was evaluating the technical feasibility of high-level nuclear waste disposal in deep ocean sediments. Working standards were needed for risk assessments, evaluation of alternative designs, sensitivity studies, and conceptual design guidelines. This report completes a three part program to develop radiological standards for the feasibility phase of the SDP. The characteristics of subseabed disposal and how they affect the selection of standards are discussed. General radiological protection standards are reviewed, along with some new methods, and a systematic approach to developing standards is presented. The selected interim radiological standards for the SDP and the reasons for their selection are given. These standards have no legal or regulatory status and will be replaced or modified by regulatory agencies if subseabed disposal is implemented. 56 refs., 29 figs., 15 tabs

  18. 40 CFR 63.309 - Performance tests and procedures.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Performance tests and procedures. 63.309 Section 63.309 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Standards for Coke Oven Batteries § 63.309 Performance tests and procedures. (a) Except as otherwise...

  19. 15 CFR 990.27 - Use of assessment procedures.

    Science.gov (United States)

    2010-01-01

    ...) NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OIL POLLUTION ACT REGULATIONS NATURAL RESOURCE DAMAGE ASSESSMENTS Authorities § 990.27 Use of assessment procedures. (a) Standards for... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Use of assessment procedures. 990.27...

  20. Validation of evaluated neutron standard cross sections

    International Nuclear Information System (INIS)

    Badikov, S.; Golashvili, T.

    2008-01-01

    Some steps of the validation and verification of the new version of the evaluated neutron standard cross sections were carried out. In particular: -) the evaluated covariance data was checked for physical consistency, -) energy-dependent evaluated cross-sections were tested in most important neutron benchmark field - 252 Cf spontaneous fission neutron field, -) a procedure of folding differential standard neutron data in group representation for preparation of specialized libraries of the neutron standards was verified. The results of the validation and verification of the neutron standards can be summarized as follows: a) the covariance data of the evaluated neutron standards is physically consistent since all the covariance matrices of the evaluated cross sections are positive definite, b) the 252 Cf spectrum averaged standard cross-sections are in agreement with the evaluated integral data (except for 197 Au(n,γ) reaction), c) a procedure of folding differential standard neutron data in group representation was tested, as a result a specialized library of neutron standards in the ABBN 28-group structure was prepared for use in reactor applications. (authors)

  1. The Standardization of Tests: Criteria and Criticisms

    Science.gov (United States)

    Weiner, Paul S.; Hoock, William C.

    1973-01-01

    Following a review of the procedures involved in the establishment of norms for standardized tests, the specific procedures used to establish norms for three tests commonly used in speech and language pathology are critically examined. (LS)

  2. Surgeon-performed endoscopic retrograde cholangiopancreatography. Outcomes of 2392 procedures at two tertiary care centers.

    Science.gov (United States)

    Al-Mansour, Mazen R; Fung, Eleanor C; Jones, Edward L; Zayan, Nichole E; Wetzel, Timothy D; Martin Del Campo, Sara E; Jalilvand, Anahita D; Suzo, Andrew J; Dettorre, Rebecca R; Fullerton, James K; Meara, Michael P; Mellinger, John D; Narula, Vimal K; Hazey, Jeffrey W

    2018-06-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is a common procedure that, in the United States, is traditionally performed by gastroenterologists. We hypothesized that when performed by well-trained surgeons, ERCP can be performed safely and effectively. The objectives of the study were to assess the rate of successful cannulation of the duct of interest and to assess the 30-day complication and mortality rates. We retrospectively reviewed the charts of 1858 patients who underwent 2392 ERCP procedures performed by five surgeons between August 2003 and June 2016 in two centers. Demographic and historical data, indications, procedure-related data and 30-day complication and mortality data were collected and analyzed. The mean age was 53.4 (range 7-102) years and 1046 (56.3%) were female. 1430 (59.8%) of ERCP procedures involved a surgical endoscopy fellow. The most common indication was suspected or established uncomplicated common bile duct stones (n = 1470, 61.5%), followed by management of an existing biliary or pancreatic stent (n = 370, 15.5%) and acute biliary pancreatitis (n = 173, 7.2%). A therapeutic intervention was performed in 1564 (65.4%), a standard sphincterotomy in 1244 (52.0%), stent placement in 705 (29.5%) and stone removal in 638 (26.7%). When cannulation was attempted, the rate of successful cannulation was 94.1%. When cannulation was attempted during the patient's first ERCP the cannulation rate was 92.4%. 94 complications occurred (5.4%); the most common complication was post-ERCP pancreatitis in 75 (4.2%), significant gastrointestinal bleeding in 7 (0.4%), ascending cholangitis in 11 (0.6%) and perforation in 1 (0.05%). 11 mortalities occurred (0.5%) but none of which were ERCP-related. When performed by well-trained surgical endoscopists, ERCP is associated with high success rate and acceptable complication rates consistent with previously published reports and in line with societal guidelines.

  3. Microbial ecology laboratory procedures manual NASA/MSFC

    Science.gov (United States)

    Huff, Timothy L.

    1990-01-01

    An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.

  4. The comparison of an inexpensive-modified transobturator vaginal tape versus TVT-O procedure for the surgical treatment of female stress urinary incontinence.

    Science.gov (United States)

    Zhang, Yan; Jiang, Min; Tong, Xiao-Wen; Fan, Bo-Zhen; Li, Huai-Fang; Chen, Xin-Liang

    2011-09-01

    To compare the safety and efficacy of an inexpensive-modified transobturator vaginal tape procedure with the transobturator tension-free vaginal tape (TVT-O) procedure for the surgical treatment of female stress urinary incontinence (SUI). Patients with SUI were randomly allocated to either the test group receiving the inexpensive-modified transobturator vaginal tape procedure or the control group receiving the GYNECARE TVT-O procedure. Treatment outcomes and Quality-of-life scores were recorded and analyzed between two groups. A total of 156 patients were enrolled in this trial. Eighty patients underwent the modified transobturator vaginal tape procedure. Among them 75(93.8%) were cured and 5(6.2%) were improved. The rest of the 76 patients underwent the GYNECARE TVT-O procedure with a 92% (70 of 76) cure rate and an 8% (6 of 76) improvement rate. No inefficient or aggravated cases occurred in both groups. The success rates between groups had no significant statistic difference (p > 0.05). The operative time, blood loss, hospital stay, and medical cost were significantly lower in the test group (p < 0.01); the increases in Quality-of-life scores were comparable between groups. The modified transobturator vaginal tape procedure is an efficacious and economic surgical treatment for female SUI. Copyright © 2011. Published by Elsevier B.V.

  5. Development of QC Procedures for Ocean Data Obtained by National Research Projects of Korea

    Science.gov (United States)

    Kim, S. D.; Park, H. M.

    2017-12-01

    To establish data management system for ocean data obtained by national research projects of Ministry of Oceans and Fisheries of Korea, KIOST conducted standardization and development of QC procedures. After reviewing and analyzing the existing international and domestic ocean-data standards and QC procedures, the draft version of standards and QC procedures were prepared. The proposed standards and QC procedures were reviewed and revised by experts in the field of oceanography and academic societies several times. A technical report on the standards of 25 data items and 12 QC procedures for physical, chemical, biological and geological data items. The QC procedure for temperature and salinity data was set up by referring the manuals published by GTSPP, ARGO and IOOS QARTOD. It consists of 16 QC tests applicable for vertical profile data and time series data obtained in real-time mode and delay mode. Three regional range tests to inspect annual, seasonal and monthly variations were included in the procedure. Three programs were developed to calculate and provide upper limit and lower limit of temperature and salinity at depth from 0 to 1550m. TS data of World Ocean Database, ARGO, GTSPP and in-house data of KIOST were analysed statistically to calculate regional limit of Northwest Pacific area. Based on statistical analysis, the programs calculate regional ranges using mean and standard deviation at 3 kind of grid systems (3° grid, 1° grid and 0.5° grid) and provide recommendation. The QC procedures for 12 data items were set up during 1st phase of national program for data management (2012-2015) and are being applied to national research projects practically at 2nd phase (2016-2019). The QC procedures will be revised by reviewing the result of QC application when the 2nd phase of data management programs is completed.

  6. Modified Arthroscopic Brostrom Procedure With Bone Tunnels.

    Science.gov (United States)

    Lui, Tun Hing

    2016-08-01

    The open anatomic repair of the anterior talofibular and calcaneofibular ligaments (modified Brostrom procedure) is widely accepted as the standard surgical stabilization procedure for lateral ankle instability that does not respond to conservative measures. Arthroscopic Brostrom procedures with a suture anchor have been reported to achieve both anatomic repair of the lateral ankle ligaments and management of the associated intra-articular lesions. However, the complication rates are higher than open Brostom procedures. Many of these complications are associated with the use of a suture anchor. We report a modified arthroscopic Brostrom procedure in which the anterolateral ankle capsule is anchored to the lateral malleolus through small bone tunnels instead of suture anchors.

  7. The update of the accounting procedures in Agricultural Cooperatives.

    Directory of Open Access Journals (Sweden)

    Rafael Enrique Viña Echevarría

    2014-06-01

    Full Text Available As part of the implementation of Internal Control in Agricultural Cooperatives from the standards established by the General Controller of the Republic, and the harmonization of accounting procedures Cuban Accounting Standards, It is need to update the accounting procedure manuals to guide and regulate the flows, times and registration basis, considering the current legislation, being these the purpose of the discussion in this investigation. The results focused on organizational dynamics of cooperatives, serving the agricultural cooperative sector and its relation to internal control and accounting management guidelines based on economic and social policy of the Party and the Revolution, as well as updating the procedure manuals. It even showed limitations in the application of internal control procedures and accounting according to the current regulations in Cuba, expressing the need to continue its development.

  8. Lead isotope analyses of standard rock samples

    International Nuclear Information System (INIS)

    Koide, Yoshiyuki; Nakamura, Eizo

    1990-01-01

    New results on lead isotope compositions of standard rock samples and their analytical procedures are reported. Bromide form anion exchange chromatography technique was adopted for the chemical separation lead from rock samples. The lead contamination during whole analytical procedure was low enough to determine lead isotope composition of common natural rocks. Silica-gel activator method was applied for emission of lead ions in the mass spectrometer. Using the data reduction of 'unfractionated ratios', we obtained good reproducibility, precision and accuracy on lead isotope compositions of NBS SRM. Here we present new reliable lead isotope compositions of GSJ standard rock samples and USGS standard rock, BCR-1. (author)

  9. Procedures for ground-water investigations

    International Nuclear Information System (INIS)

    1989-09-01

    This manual was developed by the Pacific Northwest Laboratory (PNL) to document the procedures used to carry out and control the technical aspects of ground-water investigations at the PNL. Ground-water investigations are carried out to fulfill the requirements for the US Department of Energy (DOE) to meet the requirements of DOE Orders. Investigations are also performed for various clients to meet the requirements of the Resource Conservation and Recovery Act of 1976 (RCRA) and the Comprehensive Environmental Response, Compensation and Liability Act of 1980 (CERCLA). National standards including procedures published by the American Society for Testing and Materials (ASTM) and the US Geological Survey were utilized in developing the procedures contained in this manual

  10. There is no benefit to universal carotid artery duplex screening before a major cardiac surgical procedure.

    Science.gov (United States)

    Adams, Brian C; Clark, Ross M; Paap, Christina; Goff, James M

    2014-01-01

    Perioperative stroke is a devastating complication after cardiac surgery. In an attempt to minimize this complication, many cardiac surgeons routinely preoperatively order carotid artery duplex scans to assess for significant carotid stenosis. We hypothesize that the routine screening of preoperative cardiac surgery patients with carotid artery duplex scans detects few patients who would benefit from carotid intervention or that a significant carotid stenosis reliably predicts stroke risk after cardiac surgery. A retrospective review identified 1,499 patients who underwent cardiac surgical procedures between July 1999 and September 2010. Data collected included patient demographics, comorbidities, history of previous stroke, preoperative carotid artery duplex scan results, location of postoperative stroke, and details of carotid endarterectomy (CEA) procedures before, in conjunction with, or after cardiac surgery. Statistical methods included univariate analysis and Fisher's exact test. Twenty-six perioperative strokes were identified (1.7%). In the 21 postoperative stroke patients for whom there is complete carotid artery duplex scan data, 3 patients had a hemodynamically significant lesion (>70%) and 1 patient underwent unilateral carotid CEA for bilateral disease. Postoperative strokes occurred in the anterior cerebral circulation (69.2%), posterior cerebral circulation (15.4%), or both (15.4%). Patient comorbidities, preoperative carotid artery duplex scan screening velocities, or types of cardiac surgical procedure were not predictive for stroke. Thirteen patients (0.86%) underwent CEA before, in conjunction with, or after cardiac surgery. Two of these patients had symptomatic disease, 1 of whom underwent CEA before and the other after his cardiac surgery. Of the 11 asymptomatic patients, 2 underwent CEA before, 3 concurrently, and 6 after cardiac surgery. Left main disease (≥50% stenosis), previous stroke, and peripheral vascular disease were found to be

  11. Minilaparoscopic versus standard laparoscopic hysterectomy for uteri ≥ 16 weeks of gestation: surgical outcomes, postoperative quality of life, and cosmesis.

    Science.gov (United States)

    Uccella, Stefano; Cromi, Antonella; Casarin, Jvan; Bogani, Giorgio; Serati, Maurizio; Gisone, Baldo; Pinelli, Ciro; Fasola, Maddalena; Ghezzi, Fabio

    2015-05-01

    Hysterectomy for enlarged uteri is a surgical challenge. Our aim was to compare perioperative outcomes, cosmesis, and postoperative quality of life following laparoscopic hysterectomy for large uteri using minilaparoscopic 3-mm versus conventional laparoscopic 5-mm instruments. We prospectively enrolled women with a uterus between 16 and 20 weeks of gestation at the preoperative examination. These patients underwent laparoscopic procedures using either 3-mm (minilaparoscopy group) or 5-mm (standard laparoscopy group) instruments. Five months after surgery, patients were called back to fill out the validated Italian translation of the Short Form 12-item Health Survey. Data about the cosmetic outcome of the procedure were also collected, using a Numeric Rating Scale (NRS) from 0 to 10. Seventy-eight women were included (27 in the 3-mm and 51 in the 5-mm groups). Perioperative characteristics were comparable between groups. The median uterus weight was 575 (range, 440-1050) g and 550 (400-1000) g in the 3-mm and 5-mm groups, respectively. No minilaparoscopic procedure was converted to standard 5-mm or to an open approach. One (2%) conversion to open abdominal surgery was needed in the conventional laparoscopy group. A better subjective cosmetic outcome was found in the 3-mm (NRS, 9.7 ± 0.4) versus the 5-mm (NRS, 8.9 ± 1.2) group (P=.01). Postoperative quality of life was comparable between groups. Minilaparoscopic hysterectomy is feasible, even in the case of an enlarged-size uterus. Moreover, it is associated with a better cosmetic outcome, compared with conventional laparoscopy.

  12. [Implementation of a post-discharge surgical site infection system in herniorrhaphy and mastectomy procedures].

    Science.gov (United States)

    San Juan Sanz, Isabel; Díaz-Agero-Pérez, Cristina; Robustillo-Rodela, Ana; Pita López, María José; Oliva Iñiguez, Lourdes; Monge-Jodrá, Vicente

    2014-10-01

    Monitoring surgical site infection (SSI) performed during hospitalization can underestimate its rates due to the shortening in hospital stay. The aim of this study was to determine the actual rates of SSI using a post-discharge monitoring system. All patients who underwent herniorraphy or mastectomy in the Hospital Universitario Ramón y Cajal from 1 January 2011 to 31 December 2011 were included. SSI data were collected prospectively according to the continuous quality improvement indicators (Indicadores Clinicos de Mejora Continua de la Calidad [INCLIMECC]) monitoring system. Post-discharge follow-up was conducted by telephone survey. A total of 409patients were included in the study, of whom 299 underwent a herniorraphy procedure, and 110 underwent a mastectomy procedure. For herniorrhaphy, the SSI rate increased from 6.02% to 7.6% (the post-discharge survey detected 21.7% of SSI). For mastectomy, the SSI rate increased from 1.8% to 3.6% (the post-discharge survey detected 50% of SSI). Post-discharge monitoring showed an increased detection of SSI incidence. Post-discharge monitoring is useful to analyze the real trend of SSI, and evaluate improvement actions. Post-discharge follow-up methods need to standardised. Copyright © 2013 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  13. Utility of CT-guided abdominal aspiration procedures

    International Nuclear Information System (INIS)

    Sundaram, M.; Wolverson, M.K.; Heiberg, E.; Pilla, T.; Vas, W.G.; Shields, J.B.

    1982-01-01

    Over 200 consecutive diagnostic needle aspiration procedures of the abdomen were performed under computed tomographic (CT) guidance. Biopsies were done of the liver in 88 patients, the pancreas in 28, the kidney in 20, and the retroperitoneum in 32; 30 underwent an aspiration procedure for characterization of an intraabdominal fluid collection. Accuracy of diagnosis was very high for hepatic (99%) and renal (100%) biopsies and in characterization of fluid collections (100%). Accuracy for retroperitoneal biopsy was 87.5% and for pancreatic biopsy 82%. Overall accuracy for all sites was 95%. There were one false-negative diagnosis for the liver and five false-negative diagnoses for the pancreas. Insufficient material was obtained for diagnosis in four instances of retroperitoneal biopsy. There were no false positives. The technique is facilitated by rapid CT scan time, large aperture gantry, and rapid CT image reconstruction. Twenty gauge needles were used more frequently than 22 gauge needles because of their greater rigidity and ease of control. CT-guided diagnostic aspiration procedures are particularly useful for diagnosis of small, deep-seated lesions and in evaluation of lesions found in severely ill patients. An experienced cytologist is essential to the success of the technique

  14. A company perspective on software engineering standards

    International Nuclear Information System (INIS)

    Steer, R.W.

    1988-01-01

    Software engineering standards, as implemented via formal policies and procedures, have historically been used in the nuclear industry, especially for codes used in the design, analysis, or operation of the plant. Over the past two decades, a significant amount of software has been put in place to perform these functions, while the overall software life cycle has become better understood, more and different computer systems have become available, and industry has become increasingly aware of the advantages gained when these procedures are used in the development and maintenance of this large amount of software. The use of standards and attendant procedures is thus becoming increasingly important as more computerization is taking place, both in the design and the operation of the plant. It is difficult to categorize software used in activities related to nuclear plants in a simple manner. That difficulty is due to the diversity of those uses, with attendant diversity in the methods and procedures used in the production of the software, compounded by a changing business climate in which significant software engineering expertise is being applied to a broader range of applications on a variety of computing systems. The use of standards in the various phases of the production of software thus becomes more difficult as well. This paper discusses the various types of software and the importance of software standards in the development of each of them

  15. Outcomes of Reintervention on the Autograft After Ross Procedure.

    Science.gov (United States)

    Kumar, S Ram; Bansal, Neeraj; Wells, Winfield J; Starnes, Vaughn A

    2016-11-01

    After a Ross procedure, a small subset of patients requires reintervention for autograft dilatation or valve insufficiency. We sought to determine the indications, nature, and outcomes of autograft reinterventions in the left ventricular outflow tract after a Ross procedure. We retrospectively reviewed the charts of 316 consecutive patients, age 4 days to 70 years, who underwent a Ross procedure at our institution. Of these, 47 patients (15%) required autograft reintervention during a median follow-up of 8.2 years. Forty-seven patients, median age 26 years (interquartile range [IQR], 14.4 to 44.8 years), 32 (68%) men, required autograft reintervention a median 5.5 years (IQR, 1.8 to 9.4 years) after a Ross procedure. In 47% (22 of 47 patients), the autograft valve could be salvaged (15 valve-sparing aortic replacements, 7 valve repairs). The remaining 53% underwent replacement of the root (10 mechanical, 5 homograft) or valve alone (7 mechanical, 3 bioprosthetic). Twenty patients presented without autograft root dilatation 1 year (IQR, 0.5 to 2.9 years) after Ross. Fifteen of them (75%) required valve replacement. The 27 patients who demonstrated root dilatation presented 6.9 years (IQR, 4.5 to 9.7 years; p Ross, and 17 (63%) of these valves could be spared (p = 0.01). There was no surgical mortality and 5 (11%) major morbidity events. Patients were followed up for 4.9 years (IQR, 2.1 to 7 years) after left ventricular outflow tract reintervention. For patients whose autograft valve could be spared, 3-, 5-, and 8-year freedom from valve replacement was 92%, 86%, and 86%, respectively. At last follow-up, only 1 patient had greater than mild aortic insufficiency, and all but 1 had normal ejection fraction. Autograft reintervention after a Ross appears to follow a bimodal distribution. Patients with primary autograft leaflet problems tend to present early without root dilatation and frequently require valve replacement. The autograft valve can be salvaged in the

  16. The use of Brainsuite iCT for frame-based stereotactic procedures

    DEFF Research Database (Denmark)

    Skjøth-Rasmussen, Jane; Jespersen, Bo; Brennum, Jannick

    2015-01-01

    BACKGROUND: Frame-based stereotactic procedures are the gold standard because of their superior stereotactic accuracy. The procedure used to be in multiple steps and was especially cumbersome and hazardous in intubated patients. A single-step procedure using intraoperative CT was created...

  17. Incidence of postoperative implant-related bacterial endocarditis in dogs that underwent trans-catheter embolization of a patent ductus arteriosus without intra- and post-procedural prophylactic antibiotics

    NARCIS (Netherlands)

    Szatmári, Viktor

    2017-01-01

    Intra- and post-procedural prophylactic antibiotics are routinely administered by veterinary cardiologists to dogs that undergo trans-catheter embolization of a patent ductus arteriosus for prevention of implant-related infective endocarditis. The hypothesis of our study was that primary antibiotic

  18. Reactor Section standard analytical methods. Part 1

    Energy Technology Data Exchange (ETDEWEB)

    Sowden, D.

    1954-07-01

    the Standard Analytical Methods manual was prepared for the purpose of consolidating and standardizing all current analytical methods and procedures used in the Reactor Section for routine chemical analyses. All procedures are established in accordance with accepted practice and the general analytical methods specified by the Engineering Department. These procedures are specifically adapted to the requirements of the water treatment process and related operations. The methods included in this manual are organized alphabetically within the following five sections which correspond to the various phases of the analytical control program in which these analyses are to be used: water analyses, essential material analyses, cotton plug analyses boiler water analyses, and miscellaneous control analyses.

  19. SAFE-P: System for Assurance of Flight Executable Procedures, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA operates manned spacecraft according to rigorously-defined standard operating procedures. Unfortunately, operating procedures are often written in different...

  20. Short-term effect of TVT-SECUR procedure on quality of life and sexual function in women with stress urinary incontinence.

    Science.gov (United States)

    Tang, Xiang; Zhu, Lan; Zhong, Wen; Li, Bin; Lang, Jinghe

    2013-01-01

    To investigate whether patient quality of life and sexual function are improved after the tension-free vaginal tape SECUR (TVT-S) procedure (H-type). Prospective study (Canadian Task Force classification II-3). Single-center hospital. Thirty-three women with stress urinary incontinence (SUI) (high urethral mobility) and no concomitant pelvic floor prolapse underwent TVT-S between October 2009 and October 2011. TVT-S procedure. Before and after surgery(6 and 12 months), all patients completed the Chinese version of the Incontinence Quality of Life Questionnaire (I-QOL). In addition, 28 sexually active patients who underwent the TVT-S procedure completed the short-form Pelvic Organ Prolapse/Urinary Incontinence Sexual Function Questionnaire (PISQ-12) before and after surgery (6 and 12 months). We used a paired t test to compare I-QOL scores before and after surgery. The Wilcoxon signed-rank test was used to compare the preoperative and postoperative PISQ scores. The objective cure rate was 78% (26 of 33 patients) at 12 months after surgery. The objective improvement rate was 12.1% (4 of 33 patients). The subjective satisfaction rate was 90%. Three operations (9.1%) were considered failures. Two patients underwent a TVT procedure after TVT-S because of recurrence. No patients reported severe pain; the mean (SD) visual analog scale pain score was 1.8 (1.2) after surgery. Only 1 patient (3%) was found to have sling erosion at 12 months postoperatively. The I-QOL score was 28.3 (14.2) before surgery and increased to 69.5 (18.9) at 12 months after the TVT-S procedure. The I-QOL score improved significantly after surgery (p .05). Although the objective cure rate was not high, the TVT-S procedure is a minimally invasive, safe, and effective surgical procedure for treatment of SUI (high urethral mobility) and can improve the quality of life and sexual function in women with SUI. Copyright © 2013 AAGL. Published by Elsevier Inc. All rights reserved.

  1. Adopting Ambulatory Breast Cancer Surgery as the Standard of Care in an Asian Population

    Directory of Open Access Journals (Sweden)

    Yvonne Ying Ru Ng

    2014-01-01

    Full Text Available Introduction. Ambulatory surgery is not commonly practiced in Asia. A 23-hour ambulatory (AS23 service was implemented at our institute in March 2004 to allow more surgeries to be performed as ambulatory procedures. In this study, we reviewed the impact of the AS23 service on breast cancer surgeries and reviewed surgical outcomes, including postoperative complications, length of stay, and 30-day readmission. Methods. Retrospective review was performed of 1742 patients who underwent definitive breast cancer surgery from 1 March 2004 to 31 December 2010. Results. By 2010, more than 70% of surgeries were being performed as ambulatory procedures. Younger women (P<0.01, those undergoing wide local excision (P<0.01 and those with ductal carcinoma-in situ or early stage breast cancer (P<0.01, were more likely to undergo ambulatory surgery. Six percent of patients initially scheduled for ambulatory surgery were eventually managed as inpatients; a third of these were because of perioperative complications. Wound complications, 30-day readmission and reoperation rates were not more frequent with ambulatory surgery. Conclusion. Ambulatory breast cancer surgery is now the standard of care at our institute. An integrated workflow facilitating proper patient selection and structured postoperativee outpatient care have ensured minimal complications and high patient acceptance.

  2. Laparoscopic limited Heller myotomy without anti-reflux procedure does not induce significant long-term gastroesophageal reflux.

    Science.gov (United States)

    Zurita Macías Valadez, L C; Pescarus, R; Hsieh, T; Wasserman, L; Apriasz, I; Hong, D; Gmora, S; Cadeddu, M; Anvari, M

    2015-06-01

    Laparoscopic Heller myotomy with partial fundoplication is the gold standard treatment for achalasia. Laparoscopic limited Heller myotomy (LLHM) with no anti-reflux procedure is another possible option. A review of prospectively collected data was performed on patients who underwent LLHM from January 1998 to December 2012. Evaluation included gastroscopy, esophageal manometry, 24-h pH-metry, and the Short Form(36) Health Survey(SF-36) questionnaire at baseline and 6 months, as well as the global symptom score at baseline, 6 months, and 5 years post-surgery. Comparison between outcomes was performed with a paired t student's test. 126 patients underwent LLHM. Of these, 60 patients had complete pre and post-operative motility studies. 57 % were female, patient mean age was 45.7 years, with a mean follow-up of 10.53 months. Mean operative time was 56.1 min, and the average length of stay was 1.7 days. At 6 months, a significant decrease in the lower esophageal sphincter resting pressure (29.1 vs. 7.1 mmHg; p < 0.001) and nadir (16.4 vs. 4.3 mmHg; p < 0.001) was observed. Normal esophageal acid exposure (total pH < 4 %) was observed in 68.3 % patients. Nevertheless, of the remaining 31.7 % with abnormal pH-metry, only 21.6 % were clinically symptomatic and all were properly controlled with medical treatment without requiring anti-reflux surgery. Significant improvement in all pre-operative symptoms was observed at 6 months and maintained over 5 years. Dysphagia score was reduced from 9.8 pre-operatively to 2.6 at 5 years (p < 0.001), heartburn score from 3.82 to 2 (p < 0.01), and regurgitation score from 7.5 to 0.8 (p < 0.001). Only one patient (0.8 %) presented with recurrent dysphagia requiring reoperation. LLHM without anti-reflux procedure is an effective long-term treatment for achalasia and does not cause symptomatic GERD in three quarters of patients. The remaining patients are well controlled on anti-reflux medications. It is believed that similar clinical

  3. Removal of foot-and-mouth disease virus infectivity in salted natural casings by minor adaptation of standardized industrial procedures.

    Science.gov (United States)

    Wijnker, J J; Haas, B; Berends, B R

    2007-04-10

    Intestines are used for the production of natural casings as edible sausage containers. Derived from animals (pigs and sheep) experimentally infected with FMDV (initial dosage 10(7.3) PFU/ml, strain O(1Kaufbeuren)), these natural casings were treated with sodium chloride or a phosphate salts/sodium chloride mixture and the residual FMDV titres measured. After storage at about 20 degrees C, no remaining infectivity was found after either treatment, whereas casings stored at 4 degrees C still contained infectivity. Storage of salted casings at about 20 degrees C for 30 days is already part of the Standard Operating Procedures (included in HACCP) of the international casing industry and can therefore be considered as a protective measure for the international trade in natural casings.

  4. Standardization in measurement philosophical, historical and sociological issues

    CERN Document Server

    Schlaudt, Oliver

    2015-01-01

    The application of standard measurement is a cornerstone of modern science. In this collection of essays, standardization of procedure, units of measurement and the epistemology of standardization are addressed by specialists from sociology, history and the philosophy of science.

  5. Internet of things and bariatric surgery follow-up: Comparative study of standard and IoT follow-up.

    Science.gov (United States)

    Vilallonga, Ramon; Lecube, Albert; Fort, José Manuel; Boleko, Maria Angeles; Hidalgo, Marta; Armengol, Manel

    2013-09-01

    Follow-up of obese patient is difficult. There is no literature related to patient follow-up that incorporates the concept of Internet of Things (IoT), use of WiFi, Internet, or portable devices for this purpose. This prospective observational study commenced in June 2011. Patients were prospectively offered to participate in the IoT study group, in which they received a WiFi scale (Withing®, Paris) that provides instant WiFi data to the patient and surgeon. Other patients were admitted to the standard follow-up group at the outpatient clinic. A total of 33 patients were included in our study (ten in the IoT group). Twelve patients did not have WiFi at home, ten lacked of computer knowledge, and seven preferred standard for follow-up. All patients underwent different surgical procedures. There were no complications. Excess weight loss (EWL) was similar in both groups. More than 90% of patients were satisfied. In the IoT group, patients considered it valuable in saving time, and considered seeing their evolution graphics extremely motivating. IoT technology can monitor medical parameters remotely and collect data. A WiFi scale can facilitate preoperative and follow-up. Standard follow-up in a classical outpatient clinic setting with the surgeon was preferred globally.

  6. 5 CFR 179.212 - Procedures for salary offset.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Procedures for salary offset. 179.212... COLLECTION STANDARDS Salary Offset § 179.212 Procedures for salary offset. (a) The Director or his or her designee shall coordinate salary deductions under this subpart. (b) OPM payroll office shall determine the...

  7. Procedimientos Comunes de Operacion Para Juntas Responsabilidades y Derechos del Presidente, Vice Presidente, Secretaria, y Miembros (Standard Procedures of Operation for Meetings, Rights, and Responsibilities of the President, Vice President, Secretary, and Members).

    Science.gov (United States)

    Gonzalez, Ramon

    Of use to Parent Advisory Committees, this Spanish-English handout briefly describes the standard procedures used to conduct meetings and outlines the duties of committee officers and members. The pamphlet describes the standard order of business at a meeting, including calling a meeting to order, roll call, minutes, reports, unfinished and new…

  8. A Rare Fatal Complication of Llizarov Procedure.

    Science.gov (United States)

    Sikary, Asit Kumar; Kumar, Mahesh; Dhaka, Shivani; Subramanian, Arulselvi

    2018-03-01

    Ilizarov process is used for the management of multiple fractures, polytrauma conditions, cosmetic limb lengthening, and fracture malunion. Complications associated with the process are nerve palsy, joint contracture, premature or delayed osseous consolidation, a nonunion and permanent stiffness of the joint, pin tract infection, edema, and transient paresthesia, etc. In our case, there was a fatal complication. A 25-year-old African lady underwent the Ilizarov procedure for femur lengthening in a hospital in New Delhi, India. During her first distraction process, she suddenly collapsed at the hospital and could not be revived. At postmortem, a small hematoma was seen around the surgically fractured area. On histopathology of internal organs, fat globules were present in the vasculature of brain and lungs. Cause of death was opined as due to fat embolism. This is the first case reported of a fatal fat embolism following Ilizarov procedure for limb lengthening in a healthy adult. © 2018 American Academy of Forensic Sciences.

  9. Standard Test Methods for Wet Insulation Integrity Testing of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 These test methods provide procedures to determine the insulation resistance of a photovoltaic (PV) module, i.e. the electrical resistance between the module's internal electrical components and its exposed, electrically conductive, non-current carrying parts and surfaces. 1.2 The insulation integrity procedures are a combination of wet insulation resistance and wet dielectric voltage withstand test procedures. 1.3 These procedures are similar to and reference the insulation integrity test procedures described in Test Methods E 1462, with the difference being that the photovoltaic module under test is immersed in a wetting solution during the procedures. 1.4 These test methods do not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of these test methods. 1.5 The values stated in SI units are to be regarded as the standard. 1.6 There is no similar or equivalent ISO standard. 1.7 This standard does not purport to address all of the safety conce...

  10. Evaluasi Penerapan Standard Operating Procedure-Good Agriculture Practice (SOP-GAP pada Usahatani Padi Organik di Kabupaten Bantul

    Directory of Open Access Journals (Sweden)

    Sriyadi Sriyadi

    2016-02-01

    Full Text Available Food security has meaning not only the availability of adequate food, but also providing security for producers and consumers and ensuring environmental sustainability for sustainable production. Organic farming systems are expected to solve the problem for realizing food security and enhancement of people's welfare. The results of research indicated that, (1 The implementation level of Standard Operating Procedure-Good Agriculture Practice (SOP-GAP of Organic Rice Farming in Bantul district was quite high, (2 The implementation level of SOP-GAP of Organic Rice Farming related to the availability of capital, the selling price and the purchase price of inputs (seeds and fertilizers, (3 The level of the farmer's decision related to the implementation level of SOP-GAP of organic rice farming, and (4 development of organic rice farming required availability of sufficient capital. In this regard the government, particularly the agriculture authority and food security agency need to disburse or facilitate capital for farmers in revolving as well as low interest loans.

  11. Procedures for Determining Historical Full Costs. Technical Report 65. Second Edition.

    Science.gov (United States)

    National Association of College and University Business Officers, Washington, DC.

    The procedures form the costing component of the National Center for Higher Education Management Systems'"Information Exchange Procedures" (IEP). The IEP are a set of standard definitions and procedures for collecting information about disciplines and student degree programs, outcomes of instructional programs, and general institutional…

  12. 15 CFR 10.13 - Withdrawal of a published standard.

    Science.gov (United States)

    2010-01-01

    ...) Before withdrawing a standard published under these procedures, the Director will review the relative... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Withdrawal of a published standard. 10... DEVELOPMENT OF VOLUNTARY PRODUCT STANDARDS § 10.13 Withdrawal of a published standard. (a) Standards published...

  13. Three-dimensional prototyping for procedural simulation of transcatheter mitral valve replacement in patients with mitral annular calcification.

    Science.gov (United States)

    El Sabbagh, Abdallah; Eleid, Mackram F; Matsumoto, Jane M; Anavekar, Nandan S; Al-Hijji, Mohammed A; Said, Sameh M; Nkomo, Vuyisile T; Holmes, David R; Rihal, Charanjit S; Foley, Thomas A

    2018-01-23

    Three-dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR). Eight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre-procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result. 3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post-procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model. 3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction. © 2018 Wiley Periodicals, Inc.

  14. Development and testing of standardized procedures and reference data for LWR surveillance

    International Nuclear Information System (INIS)

    McElroy, W.N.

    1979-02-01

    The resources and talents of many national and international organizations and laboratories, both governmental and industrial, are being used to establish analysis methods for predicting the embrittlement condition of light water reactor (LWR) primary systems. The exact interrelationships and responsibilities between those developing, understanding, combining, and applying state-of-the-art technology in dosimetry, metallurgy, and fracture mechanics for reactor systems analysis are being carefully reviewed and studied. This has resulted in a more comprehensive definition of the scope of new and updated ASTM standards required for the analysis and interpretation of LWR pressure vessel surveillance results. Fifteen new and updated ASTM standards have now been identified, together with a restructuring of the main interfaces between the individual standard practices, guides, and methods. The paper briefly discusses these standards and the initial results of multi-laboratory research work involved in their validation and calibration

  15. Indications for and clinical procedures resulting from magnetic resonance imaging of the knee in older patients

    Science.gov (United States)

    Parent, Marc-Etienne; Vézina, François; Carrier, Nathalie; Masetto, Ariel

    2018-01-01

    Abstract Objective To analyze the indications for and clinical procedures resulting from knee magnetic resonance imaging (MRI) in older patients. Design We retrospectively analyzed 215 medical records of patients 50 years of age and older who had undergone a unilateral knee MRI in 2009. Setting Centre hospitalier universitaire de Sherbrooke in Quebec. Participants Patients 50 years of age and older who underwent a knee MRI in 2009. Main outcome measures The main outcome measure was an invasive procedure in the same knee that underwent an MRI. Medical charts were reviewed up to 2014 for patient characteristics, MRI indication, ordering physician specialty, radiography before MRI, MRI findings, and clinical procedures resulting from the MRI. Results The patients’ mean (SD) age was 60.6 (7.5) years. The main MRI indications were meniscopathy (148 [68.8%]) and chronic pain (92 [42.8%]). The main MRI findings were osteoarthritis (OA) (185 [86.0%]) and meniscal lesions (170 [79.1%]). Only 82 (38.1%) patients had a plain radiograph in the 24 months preceding the MRI, usually without a standing anteroposterior view. Findings on pre-MRI radiography (n = 201) demonstrated OA in 144 (71.6%) patients. Overall, 87 (40.5%) patients were seen by an orthopedic surgeon and 27 (31.0%) of these patients underwent an invasive intervention. Among the 81 patients with moderate to severe OA on MRI, 36 (44.4%) had radiographic evidence of moderate to severe OA and only 3 (3.7%) underwent arthroscopic meniscectomy. Conclusion Our study reproduces the known association between OA and degenerative meniscal changes in older patients. We have found a surprising underuse of the standing anteroposterior view on radiography. Most patients in our cohort could have been appropriately diagnosed and treated based on such radiographic information, as demonstrated by pre-MRI findings, thus avoiding the MRI and subsequent evaluation by an orthopedic surgeon. Meniscectomy was rarely performed

  16. A Standardized Diagnostic Interview for Hypoactive Sexual Desire Disorder in Women

    DEFF Research Database (Denmark)

    Bitzer, Johannes; Giraldi, Annamaria; Pfaus, Jim

    2012-01-01

    procedure that is patient centered and multidimensional. Aim.  Describing a patient-centered and multidimensional standard procedure to diagnose and manage HSDD on a primary care level. Methods.  Review of the literature. Semistructured interview and description of process. Result.  The interactive process...... with the patient follows several steps: initiation, narrative of the patient to understand the individual profile of the disorder, differentiating questions, descriptive diagnosis, exploration of conditioning biomedical, individual psychological, interpersonal, and sociocultural factors (including biomedical......, and Pfaus J. A standardized diagnostic interview for Hypoactive Sexual Desire Disorder in women: standard operating procedure (SOP part 2). J Sex Med **;**:**-**....

  17. Comparison of Robotic Pyeloplasty and Standard Laparoscopic Pyeloplasty in Infants: A Bi-Institutional Study.

    Science.gov (United States)

    Neheman, Amos; Kord, Eyal; Zisman, Amnon; Darawsha, Abd Elhalim; Noh, Paul H

    2018-04-01

    To compare outcomes between robotic pyeloplasty (RP) and standard laparoscopic pyeloplasty (LP) in the infant population for the treatment of ureteropelvic junction (UPJ) obstruction. We performed a retrospective cohort study of all children under 1 year of age who underwent RP or LP at two different medical centers between October 2009 and February 2016. Patient demographics, perioperative data, complications, and results were reviewed. Thirteen patients underwent standard LP, and 21 patients underwent RP during the study period. Median age and median weight at time of operation for the whole cohort were 6.1 months and 7.9 kg. Surgery success rates were similar with 95% and 92% in RP and LP, respectively. There was no statistically significant difference in operating time between the 2 groups, with a median time of 156 minutes in RP (range 125-249) and 192 minutes (range 98-229) in standard LP (P = .35). Median length of hospital stay was significantly shorter in the robotic group with a median stay of 1 day (range 1-3) and 7 days (range 7-12) in the standard LP group.(P comparable complication rate between the 2 groups, 30.8% for LP and 23.8% for RP (P = .65). The minimally invasive dismembered pyeloplasty is safe and effective in the infant population and produces high success rates. The results, complication rates, and operative time were comparable between the two surgical methods while the standard LP demonstrated longer hospital stay. Both the robotic approach and the LP can be successfully utilized for the benefit of infants with UPJ obstruction.

  18. Air kerma standardization for diagnostic radiology in a secondary standard laboratory

    International Nuclear Information System (INIS)

    Ramos, Manoel M.O.; Peixoto, J. Guilherme P.; Lopes, Ricardo T.

    2009-01-01

    The demand for calibration services and quality control in diagnostic radiology has grown in the country since the publication of the governmental regulation 453, issued by the Brazilian Ministry of Health in 1998. At that time, to produce results facing the new legislation, many laboratories used different standards and radiation qualities, some of which could be inadequate. The international standards neither supplied consistent radiation qualities and standardization for the different types of equipment available. This situation changed with the publication of the new edition of the IEC 61267 standard, published in 2005. The objective of this work was to implement the standardization of the air kerma for the unatenuated qualities (RQR) of IEC 61267 in the National Laboratory of Metrology of the Ionizing Radiations (LNMRI) of the Institute of Radiation Protection and Dosimetry (IRD). Technical procedures were developed together with uncertainty budget. Results of interlaboratory comparisons demonstrate that the quantity is standardized and internationally traceable. (author)

  19. Is mammary reconstruction with the anatomical Becker expander a simple procedure? Complications and hidden problems leading to secondary surgical procedures: a follow-up study.

    Science.gov (United States)

    Farace, Francesco; Faenza, Mario; Bulla, Antonio; Rubino, Corrado; Campus, Gian Vittorio

    2013-06-01

    Debate over the role of Becker expander implants (BEIs) in breast reconstruction is still ongoing. There are no clear indications for BEI use. The main indications for BEI use are one-stage breast reconstruction procedure and congenital breast deformities correction, due to the postoperative ability to vary BEI volume. Recent studies showed that BEIs were removed 5 years after mammary reconstruction in 68% of operated patients. This entails a further surgical procedure. BEIs should not, therefore, be regarded as one-stage prostheses. We performed a case-series study of breast reconstructions with anatomically shaped Becker-35™ implants, in order to highlight complications and to flag unseen problems, which might entail a second surgical procedure. A total of 229 patients, reconstructed from 2005 to 2010, were enrolled in this study. Data relating to implant type, volume, mean operative time and complications were recorded. All the patients underwent the same surgical procedure. The minimum follow-up period was 18 months. During a 5-year follow-up, 99 patients required secondary surgery to correct their complications or sequelae; 46 of them underwent BEI removal within 2 years of implantation, 56 within 3 years, 65 within 4 years and 74 within 5 years. Our findings show that two different sorts of complications can arise with these devices, leading to premature implant removal, one common to any breast implant and one peculiar to BEIs. The Becker implant is a permanent expander. Surgeons must, therefore, be aware that, once positioned, the Becker expander cannot be adjusted at a later date, as in two-stage expander/prosthesis reconstructions for instance. Surgeons must have a clear understanding of possible BEI complications in order to be able to discuss these with their patients. Therefore, only surgeons experienced in breast reconstruction should use BEIs. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by

  20. 75 FR 68022 - Air Traffic Procedures Advisory Committee

    Science.gov (United States)

    2010-11-04

    ...The FAA is issuing this notice to advise the public that a new charter has been issued for the Federal Aviation Administration Air Traffic Procedures Advisory Committee (ATPAC). The duties of this advisory committee include: 1. To make recommendations for standardizing, clarifying, and upgrading terminology and procedures, as a result of its review of present ATC procedures and practices. 2. To provide advice and make recommendations concerning: a. New or significantly revised ATC procedural concepts. b. The adequacy of charts, diagrams, and illustrations used to convey information concerning the application of ATC procedures and their relevance to current, revised, or proposed ATC procedures and concepts. c. Aviation regulations that have an impact on present, new, or significantly revised ATC procedures and concepts. 3. To act solely in an advisory capacity to accomplish its duties.

  1. Program Baseline Change Control Procedure

    International Nuclear Information System (INIS)

    1993-02-01

    This procedure establishes the responsibilities and process for approving initial issues of and changes to the technical, cost, and schedule baselines, and selected management documents developed by the Office of Civilian Radioactive Waste Management (OCRWM) for the Civilian Radioactive Waste Management System. This procedure implements the OCRWM Baseline Management Plan and DOE Order 4700.1, Chg 1. It streamlines the change control process to enhance integration, accountability, and traceability of Level 0 and Level I decisions through standardized Baseline Change Proposal (BCP) forms to be used by the Level 0, 1, 2, and 3 Baseline Change Control Boards (BCCBs) and to be tracked in the OCRWM-wide Configuration Information System (CIS) Database.This procedure applies to all technical, cost, and schedule baselines controlled by the Energy System Acquisition Advisory Board (ESAAB) BCCB (Level 0) and, OCRWM Program Baseline Control Board (PBCCB) (Level 1). All baseline BCPs initiated by Level 2 or lower BCCBs, which require approval from ESAAB or PBCCB, shall be processed in accordance with this procedure. This procedure also applies to all Program-level management documents controlled by the OCRWM PBCCB

  2. Neutron cross section standards evaluations for ENDF/B-VI

    International Nuclear Information System (INIS)

    Carlson, A.D.; Poenitz, W.P.; Hale, G.M.; Peelle, R.W.

    1985-01-01

    The neutron cross section standards are now being evaluated as the initial phase in the development of the new ENDF/B-VI file. These standards evaluations are following a somewhat different process compared with that used for earlier versions of ENDF. The primary effort is concentrated on a simultaneous evaluation using a generalized least squares program, R-matrix evaluations, and a procedure for combining the results of these evaluations. The ENDF/B-VI standards evaluation procedure is outlined, and preliminary simultaneous evaluation and R-matrix results are presented. 16 refs., 7 figs

  3. 42 CFR 493.1276 - Standard: Clinical cytogenetics.

    Science.gov (United States)

    2010-10-01

    ... SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY REQUIREMENTS Quality System for Nonwaived Testing Analytic Systems § 493.1276 Standard: Clinical cytogenetics. (a) The laboratory must have policies and procedures for ensuring accurate and reliable patient specimen identification during the process...

  4. Automated procedure execution for space vehicle autonomous control

    Science.gov (United States)

    Broten, Thomas A.; Brown, David A.

    1990-01-01

    Increased operational autonomy and reduced operating costs have become critical design objectives in next-generation NASA and DoD space programs. The objective is to develop a semi-automated system for intelligent spacecraft operations support. The Spacecraft Operations and Anomaly Resolution System (SOARS) is presented as a standardized, model-based architecture for performing High-Level Tasking, Status Monitoring and automated Procedure Execution Control for a variety of spacecraft. The particular focus is on the Procedure Execution Control module. A hierarchical procedure network is proposed as the fundamental means for specifying and representing arbitrary operational procedures. A separate procedure interpreter controls automatic execution of the procedure, taking into account the current status of the spacecraft as maintained in an object-oriented spacecraft model.

  5. A standardized multidisciplinary approach reduces the use of allogeneic blood products in patients undergoing cardiac surgery.

    Science.gov (United States)

    Van der Linden, P; De Hert, S; Daper, A; Trenchant, A; Jacobs, D; De Boelpaepe, C; Kimbimbi, P; Defrance, P; Simoens, G

    2001-10-01

    Individual and institutional practices remain an independent predictor factor for allogeneic blood transfusion. Application of a standardized multidisciplinary transfusion strategy should reduce the use of allogeneic blood transfusion in major surgical patients. This prospective non randomized observational study evaluated the effects of a standardized multidisciplinary transfusion strategy on allogeneic blood products exposure in patients undergoing non-emergent cardiac surgery. The developed strategy involved a standardized blood conservation program and a multidisciplinary allogeneic blood transfusion policy based mainly on clinical judgement, not only on a specific hemoglobin concentration. Data obtained in a first group including patients operated from September 1997 to August 1998 (Group pre: n=321), when the transfusion strategy was progressively developed, were compared to those obtained in a second group, including patients operated from September 1998 to August 1999 (Group post: n=315) when the transfusion strategy was applied uniformly. Patient populations and surgical procedures were similar. Patients in Group post underwent acute normovolemic hemodilution more frequently, had a higher core temperature at arrival in the intensive care unit and presented lower postoperative blood losses at day one. Three hundred forty units of packed red blood cells were transfused in 33% of the patients in Group pre whereas 161 units were transfused in 18% of the patients in Group post (P <0.001). Pre- and postoperative hemoglobin concentrations, mortality and morbidity were not different among groups. Development of a standardized multidisciplinary transfusion strategy markedly reduced the exposure of cardiac surgery patients to allogeneic blood.

  6. 40 CFR 60.583 - Test methods and procedures.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Flexible Vinyl... following procedures: (1) Determine and record the VOC content and amount of each ink used at the print head...' formulation data along with plant blending records (if plant blending is done) may be used to determine VOC...

  7. Two new mini-slings compared with transobturator tension-free vaginal tape for treatment of stress urinary incontinence: A 1-year follow-up randomized controlled trial.

    Science.gov (United States)

    Gaber, Mohamed E; Borg, Tamer; Samour, Hazem; Nawara, Mai; Reda, Ahmed

    2016-12-01

    The aim of this study was to compare the outcome of two single-incision mini-slings (the Contasure-Needleless [C-NDL] and the endopelvic free anchorage) with the standard midurethral transobturator tension-free vaginal tape (TVT-O) procedure. A double blind randomized controlled study was conducted at Ain Shams University Maternity Hospital from August 2014 until July 2015. A total of 209 patients were randomized into three groups. The first group underwent the TVT-O procedure, the second group underwent the endopelvic free anchorage procedure and the third group underwent the C-NDL procedure. Patients were followed up for 12 months in terms of subjective cure, objective cure, and complications rate. After 12 months of follow-up, there were no differences among the three groups in terms of objective cure rate, subjective cure rate, patient satisfaction, or incidence of complications (de novo urge, hemorrhage, infection, and mesh erosion). The C-NDL was associated with a shorter operative time (P < 0.001) and less blood loss (P = 0.021) than the standard TVT-O. The new single-incision mini-slings showed similar efficacy and patient acceptance to that of the standard TVT-O for up to 12 months postoperatively with no difference in the complications rate. The C-NDL is associated with shorter operative time and less blood loss. © 2016 Japan Society of Obstetrics and Gynecology.

  8. Procedures for the selection of stopping power ratios for electron beams: Comparison of IAEA TRS procedures and of DIN procedures with Monte Carlo results

    International Nuclear Information System (INIS)

    Roos, M.; Christ, G.

    2000-01-01

    In the International Code of Practice IAEA TRS-381 the stopping power ratios water/air are selected according to the half-value depth and the depth of measurement. In the German Standard DIN 6800-2 a different procedure is recommended, which, in addition, takes the practical electron range into account; the stopping power data for monoenergetic beams from IAEA TRS-381 are used. Both procedures are compared with recent Monte Carlo calculations carried out for various beams of clinical accelerators. It is found that the DIN procedure shows a slightly better agreement. In addition, the stopping power ratios in IAEA TRS-381 are compared with those in DIN 6800-2 for the reference conditions of the beams from the PTB linac; the maximum deviation is not larger than 0.6%. (author)

  9. Effect of different pneumoperitoneum pressure on stress state in patients underwent gynecological laparoscopy

    Directory of Open Access Journals (Sweden)

    Ai-Yun Shen

    2016-10-01

    Full Text Available Objective: To observe the effect of different CO2 pneumoperitoneum pressure on the stress state in patients underwent gynecological laparoscopy. Methods: A total of 90 patients who were admitted in our hospital from February, 2015 to October, 2015 for gynecological laparoscopy were included in the study and divided into groups A, B, and C according to different CO2 pneumoperitoneum pressure. The changes of HR, BP, and PetCO2 during the operation process in the three groups were recorded. The changes of stress indicators before operation (T0, 30 min during operation (T1, and 12 h after operation (T2 were compared. Results: The difference of HR, BP, and PetCO2 levels before operation among the three groups was not statistically significant (P>0.05. HR, BP, and PetCO2 levels 30 min after pneumoperitoneum were significantly elevated when compared with before operation (P0.05. PetCO2 level 30 min after pneumoperitoneum in group B was significantly higher than that in group A (P0.05. Conclusions: Low pneumoperitoneum pressure has a small effect on the stress state in patients underwent gynecological laparoscopy, will not affect the surgical operation, and can obtain a preferable muscular relaxation and vision field; therefore, it can be selected in preference.

  10. Computing tools for implementing standards for single-case designs.

    Science.gov (United States)

    Chen, Li-Ting; Peng, Chao-Ying Joanne; Chen, Ming-E

    2015-11-01

    In the single-case design (SCD) literature, five sets of standards have been formulated and distinguished: design standards, assessment standards, analysis standards, reporting standards, and research synthesis standards. This article reviews computing tools that can assist researchers and practitioners in meeting the analysis standards recommended by the What Works Clearinghouse: Procedures and Standards Handbook-the WWC standards. These tools consist of specialized web-based calculators or downloadable software for SCD data, and algorithms or programs written in Excel, SAS procedures, SPSS commands/Macros, or the R programming language. We aligned these tools with the WWC standards and evaluated them for accuracy and treatment of missing data, using two published data sets. All tools were tested to be accurate. When missing data were present, most tools either gave an error message or conducted analysis based on the available data. Only one program used a single imputation method. This article concludes with suggestions for an inclusive computing tool or environment, additional research on the treatment of missing data, and reasonable and flexible interpretations of the WWC standards. © The Author(s) 2015.

  11. Chapter 6. Protection of patients and staff during a pandemic. Recommendations and standard operating procedures for intensive care unit and hospital preparations for an influenza epidemic or mass disaster

    NARCIS (Netherlands)

    Taylor, Bruce L.; Montgomery, Hugh E.; Rhodes, Andrew; Sprung, Charles L.; Christian, Michael D.; Camargo, Ruben; Ceraso, Daniel; Azoulay, Elie; Duguet, Alexandre; Guery, Benoit; Reinhart, Konrad; Adini, Bruria; Barlavie, Yaron; Benin-Goren, Odeda; Cohen, Robert; Klein, Motti; Leoniv, Yuval; Margalit, Gila; Rubinovitch, Bina; Sonnenblick, Moshe; Steinberg, Avraham; Weissman, Charles; Wolff, Donna; Kesecioglu, Jozef; de Jong, Menno; Moreno, Rui; An, Youzhong; Du, Bin; Joynt, Gavin M.; Colvin, John; Loo, Shi; Richards, Guy; Artigas, Antonio; Pugin, Jerome; Amundson, Dennis; Devereaux, Asha; Beigel, John; Danis, Marion; Farmer, Chris; Hick, John L.; Maki, Dennis; Masur, Henry; Rubinson, Lewis; Sandrock, Christian; Talmor, Daniel; Truog, Robert; Zimmerman, Janice; Brett, Steve; Montgomery, Hugh; Sanderson, Frances

    2010-01-01

    To provide recommendations and standard operating procedures (SOPs) for intensive care unit (ICU) and hospital preparations for an influenza pandemic or mass disaster with a specific focus on protection of patients and staff. Based on a literature review and expert opinion, a Delphi process was used

  12. Mesenteric Air Embolism Following Enteroscopic Small Bowel Tattooing Procedure

    Directory of Open Access Journals (Sweden)

    Natalie Chen

    2012-01-01

    Full Text Available Double balloon enteroscopy (DBE is a revolutionary procedure in which the entire small bowel can be visualized endoscopically. DBE has the advantage of both diagnostic and therapeutic capabilities in the setting of small bowel neoplasms and vascular malformations. We present a unique case of a 76-year-old female who underwent small bowel DBE tattoo marking of a distal small bowel tumor complicated by development of severe abdominal pain postprocedure secondary to bowel air embolism into the mesenteric veins. Mesenteric air can be seen after other endoscopic procedures such as biopsy, mucosal clip placement and polypectomy, or following a colonoscopy. Mesenteric air embolism following small bowel tattooing procedure has not been previously reported in the literature. Mesenteric air when present may be attributed to mesenteric ischemia and can subject the patient to unnecessary surgical intervention if misdiagnosed. Thus, this report holds significance for the radiologist as computed tomography (CT findings of mesenteric air embolism must be evaluated in the context of appropriate clinical history before treatment decisions are made.

  13. Development of interim test methods and procedures for determining the performance of small photovoltaic systems

    Energy Technology Data Exchange (ETDEWEB)

    McNutt, P.; Kroposki, B.; Hansen, R.; Algra, K.; DeBlasio, R. [National Renewable Energy Lab., Golden, CO (United States)

    1998-09-01

    The National Renewable Energy Laboratory (NREL) is developing tests and procedures that will determine if the configuration of a small photovoltaic (PV) system is suitable for its intended use, and if the system will perform as specified. An overview of these procedures is presented in this paper. Development of standard test procedures will allow designers, manufacturers, system integrators, users, and independent laboratories to assess the performance of PV systems under outdoor prevailing conditions. An NREL Technical Report detailing the procedures is under way, and the IEEE Standards Coordinating Committee 21 (SCC21) has established a project on this subject. The work will be submitted to the IEEE SCC21 and International Electrotechnical Commission Technical Committee 82 (IEC TC82) for consideration as a consensus standard. Certification bodies such as PowerMark and PV Global Approval Program (PVGAP) may adopt the IEC and IEEE documents when testing systems. Developing standardized test methods and procedures at NREL to evaluate the outdoor performance of PV systems will encourage product quality and promote PV standards development. Standardized tests will assure people that PV systems will perform as specified for their intended applications. As confidence in PV systems increases, the successful commercialization of PV will grow internationally.

  14. Office-based deep sedation for pediatric ophthalmologic procedures using a sedation service model.

    Science.gov (United States)

    Lalwani, Kirk; Tomlinson, Matthew; Koh, Jeffrey; Wheeler, David

    2012-01-01

    Aims. (1) To assess the efficacy and safety of pediatric office-based sedation for ophthalmologic procedures using a pediatric sedation service model. (2) To assess the reduction in hospital charges of this model of care delivery compared to the operating room (OR) setting for similar procedures. Background. Sedation is used to facilitate pediatric procedures and to immobilize patients for imaging and examination. We believe that the pediatric sedation service model can be used to facilitate office-based deep sedation for brief ophthalmologic procedures and examinations. Methods. After IRB approval, all children who underwent office-based ophthalmologic procedures at our institution between January 1, 2000 and July 31, 2008 were identified using the sedation service database and the electronic health record. A comparison of hospital charges between similar procedures in the operating room was performed. Results. A total of 855 procedures were reviewed. Procedure completion rate was 100% (C.I. 99.62-100). There were no serious complications or unanticipated admissions. Our analysis showed a significant reduction in hospital charges (average of $1287 per patient) as a result of absent OR and recovery unit charges. Conclusions. Pediatric ophthalmologic minor procedures can be performed using a sedation service model with significant reductions in hospital charges.

  15. Office-Based Deep Sedation for Pediatric Ophthalmologic Procedures Using a Sedation Service Model

    Directory of Open Access Journals (Sweden)

    Kirk Lalwani

    2012-01-01

    Full Text Available Aims. (1 To assess the efficacy and safety of pediatric office-based sedation for ophthalmologic procedures using a pediatric sedation service model. (2 To assess the reduction in hospital charges of this model of care delivery compared to the operating room (OR setting for similar procedures. Background. Sedation is used to facilitate pediatric procedures and to immobilize patients for imaging and examination. We believe that the pediatric sedation service model can be used to facilitate office-based deep sedation for brief ophthalmologic procedures and examinations. Methods. After IRB approval, all children who underwent office-based ophthalmologic procedures at our institution between January 1, 2000 and July 31, 2008 were identified using the sedation service database and the electronic health record. A comparison of hospital charges between similar procedures in the operating room was performed. Results. A total of 855 procedures were reviewed. Procedure completion rate was 100% (C.I. 99.62–100. There were no serious complications or unanticipated admissions. Our analysis showed a significant reduction in hospital charges (average of $1287 per patient as a result of absent OR and recovery unit charges. Conclusions. Pediatric ophthalmologic minor procedures can be performed using a sedation service model with significant reductions in hospital charges.

  16. Florida Sleeve Procedure Is Durable and Improves Aortic Valve Function in Marfan Syndrome Patients.

    Science.gov (United States)

    Aalaei-Andabili, Seyed Hossein; Martin, Tomas; Hess, Philip; Klodell, Charles; Karimi, Ashkan; Arnaoutakis, George; Lee, Teng; Beaver, Thomas

    2017-09-01

    The Florida sleeve (FS) procedure was developed as a simplified approach for repair of functional type I aortic insufficiency secondary to aortic root aneurysm. We evaluated postoperative aortic valve function, long-term survival, and freedom from reoperation in Marfan syndrome patients who underwent the FS procedure at our center. All Marfan syndrome patients undergoing FS procedure from May 2002 to December 2014 were included. Echocardiography assessment included left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), ejection fraction, and degree of aortic insufficiency (none = 0, minimal = 1, mild = 2, moderate = 3, severe = 4). Social Security Death Index and primary care physicians' report were used for long-term follow-up. Thirty-seven Marfan syndrome patients, 21 (56.8%) men and 16 (43%) women with mean age of 35.08 ± 13.45 years underwent FL repair at our center. There was no in-hospital or 30-day death or stroke. Two patients required reoperation due to bleeding. Patients' survival rate was 94% at 1 to 8 years. Freedom from reoperation was 100% at 8 years. Twenty-five patients had postoperative follow-up echocardiography at 1 week. Aortic insufficiency grade significantly decreased after the procedure (preoperative mean ± SD: 1.76 ± 1.2 versus 1-week postoperative mean ± SD: 0.48 ± 0.71, p Marfan syndrome patients with immediate improvement in aortic valve function. Long-term survival and freedom from reoperation rates are encouraging. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  18. Standard test methods for rockwell hardness of metallic materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 These test methods cover the determination of the Rockwell hardness and the Rockwell superficial hardness of metallic materials by the Rockwell indentation hardness principle. This standard provides the requirements for Rockwell hardness machines and the procedures for performing Rockwell hardness tests. 1.2 This standard includes additional requirements in annexes: Verification of Rockwell Hardness Testing Machines Annex A1 Rockwell Hardness Standardizing Machines Annex A2 Standardization of Rockwell Indenters Annex A3 Standardization of Rockwell Hardness Test Blocks Annex A4 Guidelines for Determining the Minimum Thickness of a Test Piece Annex A5 Hardness Value Corrections When Testing on Convex Cylindrical Surfaces Annex A6 1.3 This standard includes nonmandatory information in appendixes which relates to the Rockwell hardness test. List of ASTM Standards Giving Hardness Values Corresponding to Tensile Strength Appendix X1 Examples of Procedures for Determining Rockwell Hardness Uncertainty Appendix X...

  19. Generalized peritonitis due to perforated diverticulitis: Hartmann's procedure or primary anastomosis?

    Science.gov (United States)

    Trenti, Loris; Biondo, Sebastiano; Golda, Thomas; Monica, Millan; Kreisler, Esther; Fraccalvieri, Domenico; Frago, Ricardo; Jaurrieta, Eduardo

    2011-03-01

    Hartmann's procedure (HP) still remains the most frequently performed procedure for diffuse peritonitis due to perforated diverticulitis. The aims of this study were to assess the feasibility and safety of resection with primary anastomosis (RPA) in patients with purulent or fecal diverticular peritonitis and review morbidity and mortality after single stage procedure and Hartmann in our experience. From January 1995 through December 2008, patients operated for generalized diverticular peritonitis were studied. Patients were classified into two main groups: RPA and HP. A total of 87 patients underwent emergency surgery for diverticulitis complicated with purulent or diffuse fecal peritonitis. Sixty (69%) had undergone HP while RPA was performed in 27 patients (31%). At the multivariate analysis, RPA was associated with less post-operative complications (P clinical anastomotic leakage and needed re-operation. RPA can be safely performed without adding morbidity and mortality in cases of diffuse diverticular peritonitis. HP should be reserved only for hemodynamically unstable or high-risk patients. Specialization in colorectal surgery improves mortality and raises the percentage of one-stage procedures.

  20. Valve-sparing David I procedure in acute aortic type A dissection: a 20-year experience with more than 100 patients.

    Science.gov (United States)

    Beckmann, Erik; Martens, Andreas; Pertz, Jana; Kaufeld, Tim; Umminger, Julia; Hanke, Jasmin S; Schmitto, Jan D; Cebotari, Serghei; Haverich, Axel; Shrestha, Malakh Lal

    2017-08-01

    The aortic valve-sparing David procedure has been applied to the elective treatment of patients with aortic aneurysms with excellent results. The use of this technique in patients with acute aortic dissection type A (AADA) is still a matter of debate. We present our long-term experience with 109 patients with AADA who had the valve-sparing David I procedure. Between July 1993 and October 2015, 109 patients with AADA had the valve-sparing David I procedure at our centre. We conducted a retrospective review with follow-up. The mean age was 54 ± 12 years; 78 (72%) patients were men. Marfan syndrome was present in 6 (5%) patients and bicuspid aortic valve in 3 (3%). Only 4 (4%) patients received the isolated David procedure; 50 (46%) underwent additional proximal, 13 (12%) subtotal and 42 (39%) total aortic arch replacement. The in-hospital mortality rate was 11% ( n  = 12). Intraoperative/discharge echocardiography showed aortic insufficiency ≤ I° in 93 of 97 patients (96%). Mean follow-up time was 8.3 ± 5.7 years. The survival rate after discharge at 1, 5 and 10 years was 94%, 90% and 78%, respectively. Thirteen percent ( n  = 13) of patients underwent valve-related reoperation. Freedom from valve-related reoperation at 1, 5 and 10 years was 96%, 88% and 85%, respectively. Compared to patients who underwent the David I procedure for any reason other than AADA, there were no significant differences in long-term survival rates ( P  = 0.29) and freedom from a valve-related reoperation ( P  = 0.39). The valve-sparing David I procedure has acceptable long-term results even in emergent operations for AADA and is not inferior when performed in elective settings. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. An investigation of pre-activity cardiovascular screening procedures in health/fitness facilities--part II: rationale for low adherence with national standards.

    Science.gov (United States)

    Springer, Judy B; Eickhoff-Shemek, JoAnn M; Zuberbuehler, Ernest J

    2009-01-01

    The purpose of this study was to explore the rationale provided by program directors and general managers of health/fitness facilities for low adherence to nationally accepted standards related to pre-activity cardiovascular screening procedures (PACSPs) for members and clients of personal trainers. Qualitative interviews were conducted with the directors/managers in a Midwest region representing 76 facilities who indicated they did not conduct PACSPs for members and clients of personal trainers. Analysis of the rationale provided revealed 6 major clusters: (1) Purpose or need for screening; (2) time and staffing; (3) barrier to participation; (4) personal responsibility for health and actions; (5) legal issues; and (6) company or franchise policy that categorized the reasons for low adherence to PACSPs. These findings highlight the need to increase awareness of the relevance of PACSPs among health/fitness managers, staff members, and current exercise science students as well as engage those in risk management for informed dialogue for consistent application of the standard of care. Copyright 2009 Wiley Periodicals, Inc.

  2. Chapter 2. Surge capacity and infrastructure considerations for mass critical care. Recommendations and standard operating procedures for intensive care unit and hospital preparations for an influenza epidemic or mass disaster

    NARCIS (Netherlands)

    Hick, John L.; Christian, Michael D.; Sprung, Charles L.; Camargo, Ruben; Ceraso, Daniel; Azoulay, Elie; Duguet, Alexandre; Guery, Benoit; Reinhart, Konrad; Adini, Bruria; Barlavie, Yaron; Benin-Goren, Odeda; Cohen, Robert; Klein, Motti; Leoniv, Yuval; Margalit, Gila; Rubinovitch, Bina; Sonnenblick, Moshe; Steinberg, Avraham; Weissman, Charles; Wolff, Donna; Kesecioglu, Jozef; de Jong, Menno; Moreno, Rui; An, Youzhong; Du, Bin; Joynt, Gavin M.; Colvin, John; Loo, Shi; Richards, Guy; Artigas, Antonio; Pugin, Jerome; Amundson, Dennis; Devereaux, Asha; Beigel, John; Danis, Marion; Farmer, Chris; Maki, Dennis; Masur, Henry; Rubinson, Lewis; Sandrock, Christian; Talmor, Daniel; Truog, Robert; Zimmerman, Janice; Brett, Steve; Montgomery, Hugh; Rhodes, Andrew; Sanderson, Frances; Taylor, Bruce; Monrgomery, Hugh

    2010-01-01

    To provide recommendations and standard operating procedures for intensive care unit (ICU) and hospital preparations for a mass disaster or influenza epidemic with a specific focus on surge capacity and infrastructure considerations. Based on a literature review and expert opinion, a Delphi process

  3. 15 CFR 291.6 - Additional requirements; Federal policies and procedures.

    Science.gov (United States)

    2010-01-01

    ... and Foreign Trade NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, DEPARTMENT OF COMMERCE NIST... requirements; Federal policies and procedures. Recipients and subrecipients are subject to all Federal laws and Federal and Department of Commerce policies, regulations, and procedures applicable to Federal financial...

  4. The Disability Impact and Associated Cost per Disability in Women Who Underwent Surgical Revision of Transvaginal Mesh Kits for Prolapse Repair.

    Science.gov (United States)

    Javadian, Pouya; Shobeiri, S Abbas

    2017-09-13

    The aim of this study was to investigate disability impact in patients and cost to the families of patients who have had complications of transvaginal prolapse mesh kits and underwent surgical revision. Patients who developed complications of transvaginal mesh kits for prolapse and who had undergone vaginal prolapse mesh surgical revision/removal in 2009 to 2014 at a single institution were identified by Current Procedural Terminology codes. The group was invited to complete a phone survey pertaining to the initial vaginal mesh used for prolapse surgery utilizing Sheehan Disability Scale (scale 0-10) and Years of life Lived with Disability (YLDs) questionnaires. The data collected were used to estimate the disability and cost analysis. We used our data to estimate the economic and quality-of-life impact of vaginal mesh complications on patients in the United States RESULTS: Sixty-two patients (62/198 [31.2%]) were consented to participate and completed the questionnaires by phone. Extremely disabled patients were 18 (29%) of 62 of whole cases, and 5 (8%) of 62 reported that they had no disability after vaginal mesh surgery. The median for overall disability score after vaginal mesh procedure was 8 (which reflects marked disability on a scale of 0-10). The majority of patients missed a median of 12 months of their school or work because of their mesh complications. Thirty-seven (59.6%) of 62 did not improve after mesh removal. Twenty-one (33.9%) of 62 stated that their family income dropped because of productivity loss related to mesh complications. The mean time between vaginal mesh surgery and mesh removal procedure was 4.7 years. Sheehan Disability Scale scores are significantly correlated with YLDs outcomes. Patients' overall disability score showed a significant correlation with YLDs scores (P mesh for prolapse reduction complications had a sustained disability impact that continued despite mesh removal. Likewise, the complications were associated with

  5. A Standardized Procedure for a Pre-evaluation of the IED Instance

    Science.gov (United States)

    Panepinto, Deborah; Ruffino, Barbara; Zanetti, Mariachiara; Genon, Giuseppe

    2016-04-01

    This study presents a procedure, called EICS (Enterprise IPPC Compatibility Study) aimed at evaluating, by means of the calculation of three indexes, the compliance of the processes performed in an industrial plant with the guidelines provided by BREFs (BAT References) Documents. In fact, according to European Directive 2010/75/EU (concerning the Integrated Pollution Prevention and Control and repealing European Directive 2008/01/EC), industrial plants must require authorizations to the competent authority stating the conformity of their activity, in order to obtain this conformity they are advised to Best Available Technologies (BAT). The aim of the BATs is to avoid or minimize the impact of an industrial activity on the environment through the prevention of the atmospheric emissions, wastewater discharge and energetic consumption, and the correct waste management thus improving the efficiency of the plant. The procedure shown in the present paper has been tested on several types of industrial plant (cement plants, secondary smelt foundries, paper-mill, and automotive industries as regards their paint lines). In this paper, the application of EICS method to a cement plant is presented: the obtained results highlight a good correlation between the index values and the real situation of the plant.

  6. Comparison between primary closure with karydakis's technique versus open procedure in treatment of pilonidal sinus in terms of frequency of postoperative wound infection

    International Nuclear Information System (INIS)

    Nafees, A.U.A.; Ahmed, M.

    2013-01-01

    Objective: The purpose of this study is to compare between primary closure with Karydakis's technique versus open procedure in treatment of pilonidal sinus in terms of frequency of postoperative wound infection. Study Design: Randomized Clinical Trials (RCT). Place and Duration of Study: This study was carried out at Department of Surgery, CMH, Kharian over a period of 2 years from Sept 2010 to Oct 2012. Patients and Methods: Sixty patients were selected out of which 30 patients underwent open excision and secondary healing and 30 patients underwent Karydakis procedure. Post operatively these patients were observed for wound infection on date of discharge and weeks 1, 2 and 3. Results of both groups were compared for wound infection by applying chi-square test. Results: There was no statistically significant difference in the frequency of infection between the two groups when calculated during the complete course of study. Conclusion: Primary closure with Karydakis's technique and open procedure are satisfactory surgical procedures for pilonidal sinus disease in terms of post-operative wound infection. (author)

  7. Hypermobility of the first metatarsal bone in patients with Rheumatoid arthritis treated by lapidus procedure

    Directory of Open Access Journals (Sweden)

    Popelka Stanislav

    2012-08-01

    Full Text Available Abstract Background Foot deformities and related problems of the forefoot are very common in patients with rheumatoid arthritis. The laxity of the medial cuneometatarsal joint and its synovitis are important factors in the development of forefoot deformity. The impaired joint causes the first metatarsal bone to become unstable in the frontal and sagittal planes. In this retrospective study we evaluated data of patients with rheumatoid arthritis who underwent Lapidus procedure. We evaluated the role of the instability in a group of patients, focusing mainly on the clinical symptoms and X-ray signs of the instability. Methods The study group included 125 patients with rheumatoid arthritis. The indications of the Lapidus procedure were a hallux valgus deformity greater than 15 degrees and varus deformity of the first metatarsal bone with the intermetatarsal angle greater than 15 degrees on anterio-posterior weight-bearing X-ray. Results Data of 143 Lapidus procedures of 125 patients with rheumatoid arthritis, who underwent surgery between 2004 and 2010 was evaluated. Signs and symptoms of the first metatarsal bone instability was found in 92 feet (64.3% in our group. The AOFAS score was 48.6 before and 87.6 six months after the foot reconstruction. Nonunion of the medial cuneometatarsal joint arthrodesis on X-rays occurred in seven feet (4.9%. Conclusion The Lapidus procedure provides the possibility to correct the first metatarsal bone varus position and its instability, as well as providing the possibility to achieve a painless foot for walking. We recommend using the procedure as a preventive surgery in poorly symptomatic patients with rheumatoid arthritis in case of the first metatarsal bone hypermobility.

  8. The use of a reconstituted collagen foil dura mater substitute in paediatric neurosurgical procedures--experience in 47 patients.

    Science.gov (United States)

    Pettorini, Benedetta Ludovica; Tamburrini, Gianpiero; Massimi, Luca; Paternoster, Giovanna; Caldarelli, Massimo; Di Rocco, Concezio

    2010-02-01

    CSF leakage is a common complication of neurosurgical procedures, with defective dural suture thought to be the most frequent cause. We report our experience with a new collagen foil (TissuDura, Baxter Healthcare SA, Switzerland) utilized as dural substitute in paediatric neurosurgical procedures. TissuDura was used in children consecutively operated on at the department of paediatric neurosurgery, Catholic University, Rome, from March 2004 to August 2007. Children underwent surgical procedures in supratentorial, infratentorial and spinal compartments. In supratentorial and spinal procedures, the dural graft was used according to the overlay technique. In the posterior fossa procedures, the underlay technique was used. Forty-seven patients received TissuDura during surgery. Thirty-one patients underwent surgery for the removal of posterior fossa tumours, nine for supratentorial tumours and seven for spinal dysraphisms. No CSF leakage was observed following the use of TissuDura in supratentorial procedures. Two post-operative CSF leaks occurred in patients who had undergone spinal surgery. No post-operative hydrocephalus was noted in these two surgery groups. Three cases of CSF leakage occurred in patients who had undergone posterior cranial fossa surgery. All 3 cases had an associated supratentorial ventricular dilation present prior to the removal of the tumour (one case) or occurring after the tumour excision (two cases). No clinically evident adverse reactions directly related to TissuDura were observed. The main advantages of TissuDura were its apparent ability to prevent CSF leakage when utilized in a specific subset of patients, and the absence of reactions or postoperative infections.

  9. 22 CFR 226.44 - Procurement procedures.

    Science.gov (United States)

    2010-04-01

    ... Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ADMINISTRATION OF ASSISTANCE AWARDS TO U.S. NON-GOVERNMENTAL ORGANIZATIONS Post-award Requirements Procurement Standards § 226.44 Procurement procedures. (a... and assistance, as appropriate, of such organizations as the Small Business Administration and the...

  10. Use of a pressure sensing sheath: comparison with standard means of blood pressure monitoring in catheterization procedures.

    Science.gov (United States)

    Purdy, Phillip D; South, Charles; Klucznik, Richard P; Liu, Kenneth C; Novakovic, Robin L; Puri, Ajit S; Pride, G Lee; Aagaard-Kienitz, Beverly; Ray, Abishek; Elliott, Alan C

    2017-08-01

    Monitoring of blood pressure (BP) during procedures is variable, depending on multiple factors. Common methods include sphygmomanometer (BP cuff), separate radial artery catheterization, and side port monitoring of an indwelling sheath. Each means of monitoring has disadvantages, including time consumption, added risk, and signal dampening due to multiple factors. We sought an alternative approach to monitoring during procedures in the catheterization laboratory. A new technology involving a 330 µm fiberoptic sensor embedded in the wall of a sheath structure was tested against both radial artery catheter and sphygmomanometer readings obtained simultaneous with readings recorded from the pressure sensing system (PSS). Correlations and Bland-Altman analysis were used to determine whether use of the PSS could substitute for these standard techniques. The results indicated highly significant correlations in systolic, diastolic, and mean arterial pressures (MAP) when compared against radial artery catheterization (p<0.0001), and MAP means differed by <4%. Bland-Altman analysis of the data suggested that the sheath measurements can replace a separate radial artery catheter. While less striking, significant correlations were seen when PSS readings were compared against BP cuff readings. The PSS has competitive functionality to that seen with a dedicated radial artery catheter for BP monitoring and is available immediately on sheath insertion without the added risk of radial catheterization. The sensor is structurally separated from the primary sheath lumen and readings are unaffected by device introduction through the primary lumen. Time delays and potential complications from radial artery catheterization are avoided. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Is the frozen elephant trunk procedure superior to the conventional elephant trunk procedure for completion of the second stage?

    Science.gov (United States)

    Rustum, Saad; Beckmann, Erik; Wilhelmi, Mathias; Krueger, Heike; Kaufeld, Tim; Umminger, Julia; Haverich, Axel; Martens, Andreas; Shrestha, Malakh

    2017-10-01

    Our goal was to compare the results and outcomes of second-stage completion in patients who had previously undergone the elephant trunk (ET) or the frozen elephant trunk (FET) procedure for the treatment of complex aortic arch and descending aortic disease. Between August 2001 and December 2014, 53 patients [mean age 61 ± 13 years, 64% (n = 34) male] underwent a second-stage completion procedure. Of these patients, 32% (n = 17) had a previous ET procedure and 68% (n = 36) a previous FET procedure as a first-stage procedure. The median times to the second-stage procedure were 7 (0-78) months in the ET group and 8 (0-66) months in the FET group. The second-stage procedure included thoracic endovascular aortic repair in 53% (n = 28) of patients and open surgical repair in 47% (n = 25). More endovascular interventions were performed in FET patients (61%, n = 22) than in the ET group (35%, n = 6, P = 0.117). The in-hospital mortality rate was significantly lower in the FET (8%, n = 3) group compared with the ET group (29%, n = 5, P = 0.045). The median follow-up time after the second-stage operation for the entire cohort was 4.6 (0.4-10.4) years. The 5-year survival rate was 76% in the ET patients versus 89% in the FET patients (log-rank: P = 0.11). We observed a significantly lower in-hospital mortality rate in the FET group compared to the ET group. This result might be explained by the higher rate of endovascular completion in the FET group. We assume that the FET procedure offers the benefit of a more ideal landing zone, thus facilitating endovascular completion. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. The USL NASA PC R and D development environment standards

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Moreau, Dennis R.

    1984-01-01

    The development environment standards which have been established in order to control usage of the IBM PC/XT development systems and to prevent interference between projects being currently developed on the PC's are discussed. The standards address the following areas: scheduling PC resources; login/logout procedures; training; file naming conventions; hard disk organization; diskette care; backup procedures; and copying policies.

  13. Evaluation and standardization of different purification procedures for fish bile and liver metallothionein quantification by spectrophotometry and SDS-PAGE analyses.

    Science.gov (United States)

    Tenório-Daussat, Carolina Lyrio; Resende, Marcia Carolina Martinho; Ziolli, Roberta L; Hauser-Davis, Rachel Ann; Schaumloffel, Dirk; Saint'Pierre, Tatiana D

    2014-03-01

    Fish bile metallothioneins (MT) have been recently reported as biomarkers for environmental metal contamination; however, no studies regarding standardizations for their purification are available. Therefore, different procedures (varying centrifugation times and heat-treatment temperatures) and reducing agents (DTT, β-mercaptoethanol and TCEP) were applied to purify MT isolated from fish (Oreochromis niloticus) bile and liver. Liver was also analyzed, since these two organs are intrinsically connected and show the same trend regarding MT expression. Spectrophotometrical analyses were used to quantify the resulting MT samples, and SDS-PAGE gels were used to qualitatively assess the different procedure results. Each procedure was then statistically evaluated and a multivariate statistical analysis was then applied. A response surface methodology was also applied for bile samples, in order to further evaluate the responses for this matrix. Heat treatment effectively removes most undesired proteins from the samples, however results indicate that temperatures above 70 °C are not efficient since they also remove MTs from both bile and liver samples. Our results also indicate that the centrifugation times described in the literature can be decreased in order to analyze more samples in the same timeframe, of importance in environmental monitoring contexts where samples are usually numerous. In an environmental context, biliary MT was lower than liver MT, as expected, since liver accumulates MT with slower detoxification rates than bile, which is released from the gallbladder during feeding, and then diluted by water. Therefore, bile MT seems to be more adequate in environmental monitoring scopes regarding recent exposure to xenobiotics that may affect the proteomic and metalloproteomic expression of this biological matrix. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Modified Distal Urethral Polypropylene Sling (Canal Transobturator Tape Procedure: Efficacy for Persistent Stress Urinary Incontinence After a Conventional Midurethral Sling Procedure

    Directory of Open Access Journals (Sweden)

    Chang Hee Kim

    2013-03-01

    Full Text Available Purpose: Despite reports of persistent stress urinary incontinence (SUI in patients after the midurethral sling (MUS procedure, there is no widely accepted definition or cause of the condition. In many cases, the mesh implanted in the previous MUS procedure has been found to have migrated proximally. The aim of this study was to evaluate the efficacy of the modified distal urethral polypropylene sling, or canal transobturator tape (TOT, procedure for persistent SUI after a conventional MUS procedure on the assumption that persistent SUI after MUS is due to the location of the sling. Methods: From January 2008 to April 2012, 31 female patients who underwent the canal TOT procedure presented with incontinence or lower urinary tract symptoms (LUTS were included in this study. We identified patients who had been operated on by use of the conventional MUS procedure at other medical facilities, whose Valsalva leak pressure point was less than 120 cm-H2O by urodynamic study, and who were also diagnosed with persistent SUI. If vaginal or urethral mesh exposure was concomitant with persistent SUI, the mesh was removed completely or in part. Surgical procedures for canal TOT were identical to the original TOT procedures, except in the number and location of the vaginal incisions. Incontinence Impact Questionnaire-Short Form (IIQ-7 and Urogenital Distress Inventory-Short Form (UDI-6 scores were assessed preoperatively and at 3 months postoperatively. Results: There were no intraoperative or postoperative complications. Twenty-eight patients (90.3% showed improvement in incontinence or other LUTS. Postoperative scores of the IIQ-7 (0.65±0.48 and UDI-6 (3.48±2.28 were significantly improved compared with preoperative scores (1.26±0.58 and 7.52±4.30, respectively; P<0.05. Conclusions: Improper sling location is one of the major causes of persistent SUI after the conventional MUS procedure. Our results demonstrate that canal TOT may be an alternative

  15. Chemical vs. herbal formulations as pre-procedural mouth rinses to combat aerosol production: A randomized controlled study

    Directory of Open Access Journals (Sweden)

    Koduganti Rekha Rani

    2014-01-01

    Full Text Available Background: Disease transmission and barrier techniques are the key concerns during ultrasonic instrumentation as this procedure has the hazard of aerosol production which has a multitude of deleterious effects on the body. The aerosol produced can affect both the patient and the clinician. The aim of this study was to assess the importance of pre-procedural rinsing before scaling by ultrasonic instrumentation and to compare the efficacy of commercially available herbal mouth rinse and a Chlorhexidine gluconate mouth rinse with a control group. The study was conducted from 1 st February to 15 th April 2012 in a tertiary referral care hospital. The study was approved by the institutional ethical committee. This was a randomized single blinded interventional study, where in 36 patients equally divided into three groups participated. Material and Methods: Thirty six patients were recruited in this study aged between 18-35 years. All patients had plaque index scores between1.5-3.0, and were categorized into three groups. Patients with systemic diseases and on antibiotic therapy were excluded. Group A or control group underwent scaling with water as pre-procedural rinse, Group B used 20 ml of 0.2% Chlorhexidine and group C were administered 18 ml of a herbal pre-procedural rinse. Aerosol splatter produced during the procedure were collected on blood agar plates and sent for microbiologic analysis for the assessment of bacterial Colony Forming Units (CFUs. The mean CFUs and standard deviation (SD for each group were measured. Post hoc test was used to compare the differences between three groups, Control (A Chlorhexidine (B and Herbal (C. Results: The mean Colony Forming Units (CFUs for control group was 114.50, Chlorhexidine group was 56.75 and herbal rinse group was 47.38. Conclusion: Pre-procedural rinsing was found to be effective in reducing aerosol contamination during ultrasonic scaling though no statistically significant difference was found

  16. Procedure of trace element analysis in oyster tissues by using X-ray fluorescence

    International Nuclear Information System (INIS)

    Vo Thi Tuong Hanh; Dinh Thi Bich Lieu; Dinh Thien Lam and Nguyen Manh Hung

    2004-01-01

    The procedure of trace element analysis such as Ca, Mn, Fe, Zn, Cu, Pb in molluscs (oyster tissues) was established by using X-ray fluorescence techniques. The procedure was investigated from the sample collection, drying, ashing ratio to the analytical techniques by using Cd-109, detector Si (Li) and the peak processing MCAPLUS program was applied for this study. The procedure is based on direct comparison with certified concentrations of international standard reference SRM 1566b Oyster Tissue of National Institute of Standards and Technology, Department of commerce, United States of America for Ca, Mn, Fe, Zn, Cu and the Standard Addition Methods for Pb. The accuracy of the Standard Addition Methods was estimated by CRM281 Rye Grass of Community Bureau of Reference-BCR, European Commission. The results of 10 samples which were collected from several markets in Hanoi are shown. (author)

  17. WP1 Development of New Standardization Process

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard

    2016-01-01

    The purpose of this work package can be divided into two main areas: 1. Review of existing standardization procedures with focus on leading edge fatigue cracks and recommendations / rules for avoiding leading edge cracks. 2. Development of a new standardization process focusing on leading edge...

  18. SURF: Taking Sustainable Remediation from Concept to Standard Operating Procedure (Invited)

    Science.gov (United States)

    Smith, L. M.; Wice, R. B.; Torrens, J.

    2013-12-01

    Over the last decade, many sectors of industrialized society have been rethinking behavior and re-engineering practices to reduce consumption of energy and natural resources. During this time, green and sustainable remediation (GSR) has evolved from conceptual discussions to standard operating procedure for many environmental remediation practitioners. Government agencies and private sector entities have incorporated GSR metrics into their performance criteria and contracting documents. One of the early think tanks for the development of GSR was the Sustainable Remediation Forum (SURF). SURF brings together representatives of government, industry, consultancy, and academia to parse the means and ends of incorporating societal and economic considerations into environmental cleanup projects. Faced with decades-old treatment programs with high energy outputs and no endpoints in sight, a small group of individuals published the institutional knowledge gathered in two years of ad hoc meetings into a 2009 White Paper on sustainable remediation drivers, practices, objectives, and case studies. Since then, SURF has expanded on those introductory topics, publishing its Framework for Integrating Sustainability into Remediation Projects, Guidance for Performing Footprint Analyses and Life-Cycle Assessments for the Remediation Industry, a compendium of metrics, and a call to improve the integration of land remediation and reuse. SURF's research and members have also been instrumental in the development of additional guidance through ASTM International and the Interstate Technology and Regulatory Council. SURF's current efforts focus on water reuse, the international perspective on GSR (continuing the conversations that were the basis of SURF's December 2012 meeting at the National Academy of Sciences in Washington, DC), and ways to capture and evaluate the societal benefits of site remediation. SURF also promotes and supports student chapters at universities across the US

  19. 32 CFR 22.415 - Standards.

    Science.gov (United States)

    2010-07-01

    ... recipient of an award). (c) Have a satisfactory record of integrity and business ethics. (d) Be otherwise... Procedures § 22.415 Standards. To be qualified, a potential recipient must: (a) Have the management...

  20. How Does This Make You Feel? A Comparison of Four Affect Induction Procedures

    Directory of Open Access Journals (Sweden)

    Xuan eZhang

    2014-07-01

    Full Text Available Affect is a fundamental aspect of the human mind. An increasing number of experiments attempt to examine the influence of affect on other psychological phenomena. To accomplish this research, it is necessary to experimentally modify participants’ affective states. In the present experiment, we compared the effectiveness of four commonly used affect induction procedures. Participants were randomly assigned to either a pleasant or an unpleasant affect induction group, and then underwent four different affect induction procedures: (1 recall of an affectively salient event accompanied by affectively congruent music, (2 script-driven guided imagery, (3 viewing images while listening to affectively congruent music, and (4 posing affective facial actions, body postures, and vocal expressions. All four affect induction methods were successful in inducing both pleasant and unpleasant affective states. The combined image/music and recall/music procedures were most effective in enhancing pleasant affect, whereas the combined image/music procedure was most effective in enhancing unpleasant affect. Implications for the scientific study of affect are discussed.

  1. [Findings from Total Colonoscopy in Obstructive Colorectal Cancer Patients Who Underwent Stent Placement as a Bridge to Surgery(BTS)].

    Science.gov (United States)

    Maruo, Hirotoshi; Tsuyuki, Hajime; Kojima, Tadahiro; Koreyasu, Ryohei; Nakamura, Koichi; Higashi, Yukihiro; Shoji, Tsuyoshi; Yamazaki, Masanori; Nishiyama, Raisuke; Ito, Tatsuhiro; Koike, Kota; Ikeda, Takashi; Takayanagi, Yasuhiro; Kubota, Hiroyuki

    2017-11-01

    We clinically investigated 34 patients with obstructive colorectal cancer who underwent placement of a colonic stent as a bridge to surgery(BTS), focusing on endoscopic findings after stent placement.Twenty -nine patients(85.3%)underwent colonoscopy after stent placement, and the entire large intestine could be observed in 28(96.6%).Coexisting lesions were observed in 22(78.6%)of these 28 patients.The lesions comprised adenomatous polyps in 17 patients(60.7%), synchronous colon cancers in 5 patients(17.9%), and obstructive colitis in 3 patients(10.7%), with some overlapping cases.All patients with multiple cancers underwent one-stage surgery, and all lesions were excised at the same time.Colonoscopy after colonic stent placement is important for preoperative diagnosis of coexisting lesions and planning the extent of resection. These considerations support the utility of colonic stenting for BTS.

  2. Effects of Computer-Based Training on Procedural Modifications to Standard Functional Analyses

    Science.gov (United States)

    Schnell, Lauren K.; Sidener, Tina M.; DeBar, Ruth M.; Vladescu, Jason C.; Kahng, SungWoo

    2018-01-01

    Few studies have evaluated methods for training decision-making when functional analysis data are undifferentiated. The current study evaluated computer-based training to teach 20 graduate students to arrange functional analysis conditions, analyze functional analysis data, and implement procedural modifications. Participants were exposed to…

  3. Operator licensing examiner standards

    International Nuclear Information System (INIS)

    1993-01-01

    The Operator Licensing Examiner Standards provide policy and guidance to NRC examiners and establish the procedures and practices for examining licensees and applicants for reactor operator and senior reactor operator licenses at power reactor facilities pursuant to Part 55 of Title 10 of the Code of Federal Regulations (10 CFR 55). The Examiner Standards are intended to assist NRC examiners and facility licensees to better understand the initial and requalification examination processes and to ensure the equitable and consistent administration of examinations to all applicants. These standards are not a substitute for the operator licensing regulations and are subject to revision or other internal operator licensing policy changes

  4. The impact of changing antiseptic skin preparation agent used for cardiac implantable electronic device (CIED) procedures on the risk of infection.

    Science.gov (United States)

    Qintar, Mohammed; Zardkoohi, Omeed; Hammadah, Muhammad; Hsu, Amy; Wazni, Oussama; Wilkoff, Bruce L; Tarakji, Khaldoun G

    2015-02-01

    Cardiac implantable electronic device (CIED) infection is a major complication that is associated with increased morbidity and mortality. Recent data suggested a relationship between the antiseptic agent used for skin preparation at time of CIED procedure and risk for infection. On April 30, 2011, we changed the antiseptic agent used for skin preparation at our tertiary care facility from chlorhexidine-alcohol to povidone-iodine for all CIED procedures. We retrospectively reviewed records of all patients who underwent CIED procedure 1 year before and after the change. CIED infection was defined as pocket or endovascular systemic infection that required removal within 1 year of the index procedure. We examined if the change affected the risk of CIED infection. A total of 2,792 patients underwent 2,840 CIED procedures; 1,748 (61.5%) had implantable cardioverter defibrillator procedures and 1,092 (38.4%) had permanent pacemaker procedures. Chlorhexidine-alcohol agent was used in 1,450 (51.1%) procedures, and povidone-iodine agent was used in 1,390 (48.9%). After 1 year of follow-up, 31 patients (1.09%) developed CIED infection that required system removal. The 1-year infection rate was 1.1% among both antiseptic agent groups and there were no significant differences in the infection presentations among both groups (P = 0.950). Multivariate Cox proportional hazards regression model showed that risk factors for infection within 1 year included age, diabetes, and African American race. In one large cohort of patients undergoing CIED procedures, the antiseptic agent used for skin preparation (chlorhexidine-alcohol vs povidone-iodine) was not associated with increased risk of developing CIED infection. ©2014 Wiley Periodicals, Inc.

  5. Federal Procurement Standards Applied to School Food Services.

    Science.gov (United States)

    VanEgmond-Pannell, Dorothy

    1984-01-01

    Explains standards laid out in Federal Circular A-120 to ensure accountability, uniformity of standards, legal compliance, and efficiency in school food service procurement. Includes bidding and contract award procedures, contract compliance considerations, and cost-cutting methods. (MCG)

  6. MRI-Targeted or Standard Biopsy for Prostate-Cancer Diagnosis.

    Science.gov (United States)

    Kasivisvanathan, Veeru; Rannikko, Antti S; Borghi, Marcelo; Panebianco, Valeria; Mynderse, Lance A; Vaarala, Markku H; Briganti, Alberto; Budäus, Lars; Hellawell, Giles; Hindley, Richard G; Roobol, Monique J; Eggener, Scott; Ghei, Maneesh; Villers, Arnauld; Bladou, Franck; Villeirs, Geert M; Virdi, Jaspal; Boxler, Silvan; Robert, Grégoire; Singh, Paras B; Venderink, Wulphert; Hadaschik, Boris A; Ruffion, Alain; Hu, Jim C; Margolis, Daniel; Crouzet, Sébastien; Klotz, Laurence; Taneja, Samir S; Pinto, Peter; Gill, Inderbir; Allen, Clare; Giganti, Francesco; Freeman, Alex; Morris, Stephen; Punwani, Shonit; Williams, Norman R; Brew-Graves, Chris; Deeks, Jonathan; Takwoingi, Yemisi; Emberton, Mark; Moore, Caroline M

    2018-05-10

    Multiparametric magnetic resonance imaging (MRI), with or without targeted biopsy, is an alternative to standard transrectal ultrasonography-guided biopsy for prostate-cancer detection in men with a raised prostate-specific antigen level who have not undergone biopsy. However, comparative evidence is limited. In a multicenter, randomized, noninferiority trial, we assigned men with a clinical suspicion of prostate cancer who had not undergone biopsy previously to undergo MRI, with or without targeted biopsy, or standard transrectal ultrasonography-guided biopsy. Men in the MRI-targeted biopsy group underwent a targeted biopsy (without standard biopsy cores) if the MRI was suggestive of prostate cancer; men whose MRI results were not suggestive of prostate cancer were not offered biopsy. Standard biopsy was a 10-to-12-core, transrectal ultrasonography-guided biopsy. The primary outcome was the proportion of men who received a diagnosis of clinically significant cancer. Secondary outcomes included the proportion of men who received a diagnosis of clinically insignificant cancer. A total of 500 men underwent randomization. In the MRI-targeted biopsy group, 71 of 252 men (28%) had MRI results that were not suggestive of prostate cancer, so they did not undergo biopsy. Clinically significant cancer was detected in 95 men (38%) in the MRI-targeted biopsy group, as compared with 64 of 248 (26%) in the standard-biopsy group (adjusted difference, 12 percentage points; 95% confidence interval [CI], 4 to 20; P=0.005). MRI, with or without targeted biopsy, was noninferior to standard biopsy, and the 95% confidence interval indicated the superiority of this strategy over standard biopsy. Fewer men in the MRI-targeted biopsy group than in the standard-biopsy group received a diagnosis of clinically insignificant cancer (adjusted difference, -13 percentage points; 95% CI, -19 to -7; Pprostate cancer who had not undergone biopsy previously. (Funded by the National Institute for

  7. Software Development Standard Processes (SDSP)

    Science.gov (United States)

    Lavin, Milton L.; Wang, James J.; Morillo, Ronald; Mayer, John T.; Jamshidian, Barzia; Shimizu, Kenneth J.; Wilkinson, Belinda M.; Hihn, Jairus M.; Borgen, Rosana B.; Meyer, Kenneth N.; hide

    2011-01-01

    A JPL-created set of standard processes is to be used throughout the lifecycle of software development. These SDSPs cover a range of activities, from management and engineering activities, to assurance and support activities. These processes must be applied to software tasks per a prescribed set of procedures. JPL s Software Quality Improvement Project is currently working at the behest of the JPL Software Process Owner to ensure that all applicable software tasks follow these procedures. The SDSPs are captured as a set of 22 standards in JPL s software process domain. They were developed in-house at JPL by a number of Subject Matter Experts (SMEs) residing primarily within the Engineering and Science Directorate, but also from the Business Operations Directorate and Safety and Mission Success Directorate. These practices include not only currently performed best practices, but also JPL-desired future practices in key thrust areas like software architecting and software reuse analysis. Additionally, these SDSPs conform to many standards and requirements to which JPL projects are beholden.

  8. 46 CFR 164.019-7 - Non-standard components; acceptance criteria and procedures.

    Science.gov (United States)

    2010-10-01

    ... must include a description of the quality control procedures that will be in effect during production... oversight of the manufacturer's program of production quality control, including a description of the... the case of textiles. (5) The request must include a list of all materials used in the construction of...

  9. Patient doses from fluoroscopically guided cardiac procedures in pediatrics

    International Nuclear Information System (INIS)

    Martinez, L C; Vano, E; Gutierrez, F; Rodriguez, C; Gilarranz, R; Manzanas, M J

    2007-01-01

    Infants and children are a higher risk population for radiation cancer induction compared to adults. Although some values on pediatric patient doses for cardiac procedures have been reported, data to determine reference levels are scarce, especially when compared to those available for adults in diagnostic and therapeutic procedures. The aim of this study is to make a new contribution to the scarce published data in pediatric cardiac procedures and help in the determination of future dose reference levels. This paper presents a set of patient dose values, in terms of air kerma area product (KAP) and entrance surface air kerma (ESAK), measured in a pediatric cardiac catheterization laboratory equipped with a biplane x-ray system with dynamic flat panel detectors. Cardiologists were properly trained in radiation protection. The study includes 137 patients aged between 10 days and 16 years who underwent diagnostic catheterizations or therapeutic procedures. Demographic data and technical details of the procedures were also gathered. The x-ray system was submitted to a quality control programme, including the calibration of the transmission ionization chamber. The age distribution of the patients was 47 for 2 respectively for the four age bands. These KAP values increase by a factor of 8 when moving through the four age bands. The probability of a fatal cancer per fluoroscopically guided cardiac procedure is about 0.07%. Median values of ESAK for the four age bands were 46, 50, 56 and 163 mGy, which lie far below the threshold for deterministic effects on the skin. These dose values are lower than those published in previous papers

  10. Microdose flare-up vs. flexible-multidose GnRH antagonist protocols for poor responder patients who underwent ICSI.

    Science.gov (United States)

    Esinler, I

    2014-01-01

    To compare the performance of microdose flare-up (MF) and flexible-multidose gonadotropin-releasing hormone (GnRH) antagonist protocols in poor responder patients who underwent intracytoplasmic sperm injection (ICSI). One hundred and 12 consecutive patients (217 cycles) suspected to have poor ovarian response were enrolled. Group 1 (MF GnRH agonist group) constituted 64 patients (135 cycles) who underwent MF GnRH agonist protocol. Group 2 (flexible-multidose GnRH antagonist group) constituted 48 patients (82 cycles) who underwent flexible-multidose GnRH antagonist protocol. The duration of stimulation (d) (11.5 +/- 2.1 vs. 10.4 +/- 2.7, p or = seven blastomeres and < 10% fragmentation at day 3 (35.9% vs. 65.1%, p < 0.05) were significantly lower in Group 1 when compared to Group 2. The number of embryos transferred (2.2 +/- 1.3 vs. 2.4 +/- 0.9), the clinical pregnancy per embryo transfer (16.3% vs. 25.8%), and the implantation rate (8.6% vs. 12.2%) were comparable between groups. Although the flexible-multidose GnRH antagonist protocol produced better oocyte and embryo parameters, the clinical pregnancy rate and the implantation rates were comparable between the flexible-multidose GnRH antagonist and MF protocols in poor responder patients.

  11. Calibration of photon and beta ray sources used in brachytherapy. Guidelines on standardized procedures at Secondary Standards Dosimetry Laboratories (SSDLs) and hospitals

    International Nuclear Information System (INIS)

    2002-03-01

    It has generally been recognized that international harmonization in radiotherapy dosimetry is essential. Consequently, the IAEA has given much effort to this, for example by publishing a number of reports in the Technical Reports Series (TRS) for external beam dosimetry, most notably TRS-277 and more recently TRS-398. Both of these reports describe in detail the steps to be taken for absorbed dose determination in water and they are often referred to as 'dosimetry protocols'. Similar to TRS-277, it is expected that TRS-398 will be adopted or used as a model by a large number of countries as their national protocol. In 1996, the IAEA established a calibration service for low dose rate (LDR) 137 Cs brachytherapy sources, which is the most widely used source for treatment of gynecological cancer. To further enhance harmonization in brachytherapy dosimetry, the IAEA published in 1999 IAEA-TECDOC-1079 entitled 'Calibration of Brachytherapy Sources. Guidelines on Standardized Procedures for the Calibration of Brachytherapy Sources at Secondary Standard Dosimetry Laboratories (SSDLs) and Hospitals'. The report was well received and was distributed in a large number of copies to the members of the IAEA/WHO network of SSDLs and to medical physicists working with brachytherapy. The present report is an update of the aforementioned TECDOC. Whereas TECDOC-1079 described methods for calibrating brachytherapy sources with photon energies at or above those of 192 Ir, the current report has a wider scope in that it deals with standardization of calibration of all the most commonly used brachytherapy sources, including both photon and beta emitting sources. The latter sources have been in use for a few decades already, but their calibration methods have been unclear. Methods are also described for calibrating sources used in the rapidly growing field of cardiovascular angioplasty. In this application, irradiation of the vessel wall is done in an attempt to prevent restenosis after

  12. Operating procedures for the Pajarito Site Critical Assembly Facility

    International Nuclear Information System (INIS)

    Malenfant, R.E.

    1983-03-01

    Operating procedures consistent with DOE Order 5480.2, Chapter VI, and the American National Standard Safety Guide for the Performance of Critical Experiments are defined for the Pajarito Site Critical Assembly Facility of the Los Alamos National Laboratory. These operating procedures supersede and update those previously published in 1973 and apply to any criticality experiment performed at the facility

  13. 14 CFR 97.3 - Symbols and terms used in procedures.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Symbols and terms used in procedures. 97.3 Section 97.3 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES STANDARD INSTRUMENT PROCEDURES General § 97.3 Symbols and...

  14. standards used for quality control of nuclear fuels

    International Nuclear Information System (INIS)

    Guereli, L; Can, S.

    1997-01-01

    Nuclear fuels and fuel materials are subject to stringent restrictions as to their quality. The standards and regulations that apply vary according to reactor type and country and the standards are stated in the quality assurance documents. The concept of quality assurance has altered the conventional quality control tests and procedures, defining which control tests are to be applied and how. Although most of the tests and measurements allow the determination of tolerances to be decided according to the agreement between the buyer and the seller, exacting procedures apply to which instruments and equipment are used for these tests and measurements, how these instruments are standardized.Detailed explanations of test methods and their documentation is a requirement in all standards. The purpose of this work is to study which standards, tests and measurements apply to the nuclear fuel production. Only the standards that apply to various stages of the nuclear fuel production (powder preparation, pellet production, fuel element and fuel assembly fabrication) are reviewed. Process and documentation control, design and licensing requirements and the frequency of inspections are quality assurance subjects. Some ASTM standards are given as examples

  15. Real-time eye lens dose monitoring during cerebral angiography procedures

    Energy Technology Data Exchange (ETDEWEB)

    Safari, M.J.; Wong, J.H.D.; Kadir, K.A.A.; Ng, K.H. [University of Malaya, Department of Biomedical Imaging, Faculty of Medicine, Kuala Lumpur (Malaysia); University of Malaya, University of Malaya Research Imaging Centre (UMRIC), Faculty of Medicine, Kuala Lumpur (Malaysia); Thorpe, N.K.; Cutajar, D.L.; Petasecca, M.; Lerch, M.L.F.; Rosenfeld, A.B. [University of Wollongong, Centre for Medical Radiation Physics (CMRP), Wollongong, NSW (Australia)

    2016-01-15

    To develop a real-time dose-monitoring system to measure the patient's eye lens dose during neuro-interventional procedures. Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures. The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R{sup 2}) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AK{sub L}: 0.93, AK{sub F}: 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions. The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose. (orig.)

  16. Real-time eye lens dose monitoring during cerebral angiography procedures

    International Nuclear Information System (INIS)

    Safari, M.J.; Wong, J.H.D.; Kadir, K.A.A.; Ng, K.H.; Thorpe, N.K.; Cutajar, D.L.; Petasecca, M.; Lerch, M.L.F.; Rosenfeld, A.B.

    2016-01-01

    To develop a real-time dose-monitoring system to measure the patient's eye lens dose during neuro-interventional procedures. Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures. The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R 2 ) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AK L : 0.93, AK F : 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions. The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose. (orig.)

  17. Cortical Blindness In Fat Embolism Syndrome Following Fracture Manipulative Procedure

    Directory of Open Access Journals (Sweden)

    A Shahrulazua

    2010-03-01

    Full Text Available Fat embolism syndrome is a well-recognised sequela of long bone trauma as well as intramedullary orthopaedic procedures. However, it has rarely been described following manipulation, reduction of fracture, and application of external fixator. Furthermore, bilateral ocular blindness is seldom the first manifestation; instead respiratory and other cerebral symptoms being most common. We describe a case with this rare presentation in a patient who underwent a trial of closed reduction, then open reduction of a femur fracture, followed by external fixation performed at day 47 post-initial trauma.

  18. Acid Rain Analysis by Standard Addition Titration.

    Science.gov (United States)

    Ophardt, Charles E.

    1985-01-01

    The standard addition titration is a precise and rapid method for the determination of the acidity in rain or snow samples. The method requires use of a standard buret, a pH meter, and Gran's plot to determine the equivalence point. Experimental procedures used and typical results obtained are presented. (JN)

  19. Developing and enforcing internal information systems standards: InduMaker’s Standards Management Process

    Directory of Open Access Journals (Sweden)

    Claudia Loebbecke

    2016-01-01

    Full Text Available It is widely agreed that standards provide numerous benefits when available and enforced. Company-internal Information Systems (IS management procedures and solutions, in the following coined IS ‘standards’, allow for harmonizing operations between company units, locations and even different service providers. However, many companies lack an organized process for defining and managing internal IS standards, which causes uncertainties and delays in decision making, planning, and design processes. In this case study of the globally operating InduMaker (anonymized company name, an established manufacturing supplier, we look into the company-internal management of IS standards. Theoretically grounded in the organizational and IS-focused literature on business process modelling and business process commoditization, we describe and investigate InduMaker’s newly developed Standard Management Process (SMP for defining and managing company-internal business and IS standards, with which the multinational pursues offering clear answers to business and IT departments about existing IS standards, their degree of obligation, applicability, and scope at any time.

  20. Digital forensic standards: international progress

    CSIR Research Space (South Africa)

    Grobler, MM

    2010-05-01

    Full Text Available With the explosion of digital crime, digital forensics is more often applied. The digital forensic discipline developed rather rapidly, but up to date very little international standardization with regard to processes, procedures or management has...

  1. Results of a national survey on nuclear medicine procedures

    International Nuclear Information System (INIS)

    Curti, A.R.; Gatica, N.A.; Melis, H.J.

    1998-01-01

    Full text: In 1997, the Nuclear Regulatory Authority of Argentina carried out a compilation of data on radiopharmaceuticals administered to patients in nuclear medicine procedures. Its aim was to get information on the radiopharmaceuticals that are used in different procedures and the activity administered to the patient, to assess the radiation exposure of the population and to contribute to a global survey of medical radiation usage and exposures conducted by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), by sending information of the country. The data compiled were analysed, and for the most frequent procedures, the mean activity administered, the standard deviation, the distribution of the number of procedures for different age groups, sex and radiopharmaceuticals were assessed. The radiation exposure for children and adults was estimated. For the main diagnostic examinations, the results of the survey were compared with specific values published in the Basic Safety Standards of the International Atomic Energy Agency (Safety Series No. 115, 1996). As a conclusion, it may be point out the importance of continuing with the compilation of this kind of information in order to identify emerging trends on the use of nuclear medicine procedures in Argentina and the activity of radiopharmaceuticals administered to the patients. (author) [es

  2. Revising The Standards For Financial Reporting In Ghana | Appiah ...

    African Journals Online (AJOL)

    The need to strengthen financial reporting through standard setting in Ghana has been examined. The roles of the Institute of Chartered Accountants (Ghana) and Ghana National Accounting Standards Board were found not to be addressing the revision and updating of the standards, and bringing the procedures and ...

  3. New standards for digital radiography and qualification of detectors; Neue Standards zur Digitalen Radiographie und Qualifizierung von Detektoren

    Energy Technology Data Exchange (ETDEWEB)

    Ewert, Uwe; Zscherpel, Uwe [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany)

    2017-08-01

    The contribution describes the most important standards for radiographic examinations that are revised in different committees. Information is given on new requirements esp. on revised parameters that have to be considered in practical testing procedures and classification. Actually for the revision of ISO 17636-1/2 in 2018 user questions are collected concerning weld seam testing. The DIN 25435 standards for weld seam testing in nuclear technology have been translated into English. Revisions of ASTM standards have to be considered in the actual EN and ISO standards. Since several years the International Institute of Welding (IIW) is also revising the international standards.

  4. Beyond the standard model

    International Nuclear Information System (INIS)

    Cuypers, F.

    1997-05-01

    These lecture notes are intended as a pedagogical introduction to several popular extensions of the standard model of strong and electroweak interactions. The topics include the Higgs sector, the left-right symmetric model, grand unification and supersymmetry. Phenomenological consequences and search procedures are emphasized. (author) figs., tabs., 18 refs

  5. Powered bone marrow biopsy procedures produce larger core specimens, with less pain, in less time than with standard manual devices

    Directory of Open Access Journals (Sweden)

    Larry J. Miller

    2011-07-01

    Full Text Available Bone marrow sampling remains essential in the evaluation of hematopoietic and many non-hematopoietic disorders. One common limitation to these procedures is the discomfort experienced by patients. To address whether a Powered biopsy system could reduce discomfort while providing equivalent or better results, we performed a randomized trial in adult volunteers. Twenty-six subjects underwent bilateral biopsies with each device. Core samples were obtained in 66.7% of Manual insertions; 100% of Powered insertions (P=0.002. Initial mean biopsy core lengths were 11.1±4.5 mm for the Manual device; 17.0±6.8 mm for the Powered device (P<0.005. Pathology assessment for the Manual device showed a mean length of 6.1±5.6 mm, width of 1.0±0.7 mm, and volume of 11.0±10.8 mm3. Powered device measurements were mean length of 15.3±6.1 mm, width of 2.0±0.3 mm, and volume of 49.1±21.5 mm3 (P<0.001. The mean time to core ejection was 86 seconds for Manual device; 47 seconds for the Powered device (P<0.001. The mean second look overall pain score was 33.3 for the Manual device; 20.9 for the Powered (P=0.039. We conclude that the Powered biopsy device produces superior sized specimens, with less overall pain, in less time.

  6. Qualitative research within trials: developing a standard operating procedure for a clinical trials unit

    Science.gov (United States)

    2013-01-01

    Background Qualitative research methods are increasingly used within clinical trials to address broader research questions than can be addressed by quantitative methods alone. These methods enable health professionals, service users, and other stakeholders to contribute their views and experiences to evaluation of healthcare treatments, interventions, or policies, and influence the design of trials. Qualitative data often contribute information that is better able to reform policy or influence design. Methods Health services researchers, including trialists, clinicians, and qualitative researchers, worked collaboratively to develop a comprehensive portfolio of standard operating procedures (SOPs) for the West Wales Organisation for Rigorous Trials in Health (WWORTH), a clinical trials unit (CTU) at Swansea University, which has recently achieved registration with the UK Clinical Research Collaboration (UKCRC). Although the UKCRC requires a total of 25 SOPs from registered CTUs, WWORTH chose to add an additional qualitative-methods SOP (QM-SOP). Results The qualitative methods SOP (QM-SOP) defines good practice in designing and implementing qualitative components of trials, while allowing flexibility of approach and method. Its basic principles are that: qualitative researchers should be contributors from the start of trials with qualitative potential; the qualitative component should have clear aims; and the main study publication should report on the qualitative component. Conclusions We recommend that CTUs consider developing a QM-SOP to enhance the conduct of quantitative trials by adding qualitative data and analysis. We judge that this improves the value of quantitative trials, and contributes to the future development of multi-method trials. PMID:23433341

  7. Standard Review Plan Update and Development Program

    International Nuclear Information System (INIS)

    1992-05-01

    This implementing procedures document (IPD) was prepared for use in implementing tasks under the standard review plan update and development program (SRP-UDP). The IPD provides comprehensive guidance and detailed procedures for SRP-UDP tasks. The IPD is mandatory for contractors performing work for the SRP-UDP. It is guidance for the staff. At the completion of the SRP-UDP, the IPD will be revised (to remove the UDP aspects) and will replace NRR Office Letter No. 800 as long-term maintenance procedures

  8. Standard Review Plan Update and Development Program

    Energy Technology Data Exchange (ETDEWEB)

    1992-05-01

    This implementing procedures document (IPD) was prepared for use in implementing tasks under the standard review plan update and development program (SRP-UDP). The IPD provides comprehensive guidance and detailed procedures for SRP-UDP tasks. The IPD is mandatory for contractors performing work for the SRP-UDP. It is guidance for the staff. At the completion of the SRP-UDP, the IPD will be revised (to remove the UDP aspects) and will replace NRR Office Letter No. 800 as long-term maintenance procedures.

  9. Acute Procedural Pain in Children

    DEFF Research Database (Denmark)

    Kristensen, Helle Nygård; Lundbye-Christensen, Søren; Haslund-Thomsen, Helle

    2018-01-01

    INTRODUCTION: Hospitalized children often describe needle-related procedures as the worst pain possible and such procedures may be emotionally traumatic. The use of hospital clowns related to painful medical procedures in children may offer pain relief, but this has not been systematically...... evaluated. The objective of this study was to assess the effect of a therapeutic clown in comparison to standard care on the experience of pain for children receiving venipuncture. METHODS: A sample of 116 children aged 4-15 years consecutively admitted to the hospital was allocated to either......: Without the clown present, the mean pain score (2.7±2.8) was not significantly different between the two age groups. Children aged 7-15 years had lower pain scores when the clown was present compared to the control group (P=0.025). Children aged 4-6 years had higher pain scores with the clown present...

  10. Standardization of biodosimetry operations

    International Nuclear Information System (INIS)

    Dainiak, Nicholas

    2016-01-01

    Methods and procedures for generating, interpreting and scoring the frequency of dicentric chromosomes vary among cytogenetic biodosimetry laboratories (CBLs). This variation adds to the already considerable lack of precision inherent in the dicentric chromosome assay (DCA). Although variability in sample collection, cell preparation, equipment and dicentric frequency scoring can never be eliminated with certainty, it can be substantially minimized, resulting in reduced scatter and improved precision. Use of standard operating procedures and technician exchange may help to mitigate variation. Although the development and adoption of international standards (ISO 21243 and ISO 19238) has helped to reduce variation in standard operating procedures (SOPs), all CBLs must maintain process improvement, and those with challenges may require additional assistance. Sources of variation that may not be readily apparent in the SOPs for sample collection and processing include variability in ambient laboratory conditions, media, serum lot and quantity and the use of particular combinations of cytokines. Variability in maintenance and calibration of metafer equipment, and in scoring criteria, reader proficiency and personal factors may need to be addressed. The calibration curve itself is a source of variation that requires control, using the same known-dose samples among CBLs, measurement of central tendency, and generation of common curves with periodic reassessment to detect drifts in dicentric yield. Finally, the dose estimate should be based on common scoring criteria, using of the z-statistic. Although theoretically possible, it is practically impossible to propagate uncertainty over the entire calibration curve due to the many factors contributing to variance. Periodic re-evaluation of the curve is needed by comparison with newly published curves (using statistical analysis of differences) and determining their potential causes. (author)

  11. Operator licensing examiner standards

    International Nuclear Information System (INIS)

    1983-10-01

    The Operator Licensing Examiner Standards provide policy and guidance to NRC examiners and establish the procedures and practices for examining and licensing of applicants for NRC operator licenses pursuant to Part 55 of Title 10 of the Code of Federal Regulations (10 CFR 55). They are intended to assist NRC examiners and facility licensees to understand the examination process better and to provide for equitable and consistent administration of examinations to all applicants by NRC examiners. These standards are not a substitute for the operator licensing regulations and are subject to revision or other internal operator examination licensing policy changes. As appropriate, these standards will be revised periodically to accommodate comments and reflect new information or experience

  12. Standardized physics-dosimetry for US pressure vessel cavity surveillance programs

    International Nuclear Information System (INIS)

    Ruddy, F.H.; McElroy, W.N.; Lippincott, E.P.

    1984-01-01

    This paper summarizes the applications of ASTM standard methods, guides and practices to define the selection and deployment of recommended dosimetry sets, the selection of dosimetry capsules and thermal neutron shields, the placement of dosimetry, the methods of measurement of dosimetry sensor reaction products, data analysis procedures, and uncertainty evaluation procedures. It also describes the validation of these standards both by in-reactor testing of advanced PV cavity surveillance physics-dosimetry and by data development. The use of these standards to guide selection and development of advanced dosimetry sets for commercial reactors is also summarized. (Auth.)

  13. Prediction of Pathological Complete Response Using Endoscopic Findings and Outcomes of Patients Who Underwent Watchful Waiting After Chemoradiotherapy for Rectal Cancer.

    Science.gov (United States)

    Kawai, Kazushige; Ishihara, Soichiro; Nozawa, Hiroaki; Hata, Keisuke; Kiyomatsu, Tomomichi; Morikawa, Teppei; Fukayama, Masashi; Watanabe, Toshiaki

    2017-04-01

    Nonoperative management for patients with rectal cancer who have achieved a clinical complete response after chemoradiotherapy is becoming increasingly important in recent years. However, the definition of and modality used for patients with clinical complete response differ greatly between institutions, and the role of endoscopic assessment as a nonoperative approach has not been fully investigated. This study aimed to investigate the ability of endoscopic assessments to predict pathological regression of rectal cancer after chemoradiotherapy and the applicability of these assessments for the watchful waiting approach. This was a retrospective comparative study. This study was conducted at a single referral hospital. A total of 198 patients with rectal cancer underwent preoperative endoscopic assessments after chemoradiotherapy. Of them, 186 patients underwent radical surgery with lymph node dissection. The histopathological findings of resected tissues were compared with the preoperative endoscopic findings. Twelve patients refused radical surgery and chose watchful waiting; their outcomes were compared with the outcomes of patients who underwent radical surgery. The endoscopic criteria correlated well with tumor regression grading. The sensitivity and specificity for a pathological complete response were 65.0% to 87.1% and 39.1% to 78.3%. However, endoscopic assessment could not fully discriminate pathological complete responses, and the outcomes of patients who underwent watchful waiting were considerably poorer than the patients who underwent radical surgery. Eventually, 41.7% of the patients who underwent watchful waiting experienced uncontrollable local failure, and many of these occurrences were observed more than 3 years after chemoradiotherapy. The number of the patients treated with the watchful waiting strategy was limited, and the selection was not randomized. Although endoscopic assessment after chemoradiotherapy correlated with pathological response

  14. Colon trauma: primary repair evolving as the standard of care.

    Science.gov (United States)

    Muffoletto, J. P.; Tate, J. S.

    1996-01-01

    This study reviewed the management of colon injuries treated at the trauma surgical service, University of Nevada Medical Center between 1987 and 1992. Sixty-six patients sustained either blunt or penetrating colon injuries during the study period. The patients were divided into two groups: patients who underwent diverting colostomies and patients who underwent primary repair. Both groups were equally matched in terms of colon injury severity as well as trauma scores. The results indicated that primary colon repair was as safe if not safer than colostomy with less complications and at lower costs. The authors conclude that primary repair should be reevaluated in a critical manner as an evolving standard of care. PMID:8855649

  15. Groundwater technical procedures of the U.S. Geological Survey

    Science.gov (United States)

    Cunningham, William L.; Schalk, Charles W.

    2011-01-01

    A series of groundwater technical procedures documents (GWPDs) has been released by the U.S. Geological Survey, Water-Resources Discipline, for general use by the public. These technical procedures were written in response to the need for standardized technical procedures of many aspects of groundwater science, including site and measuring-point establishment, measurement of water levels, and measurement of well discharge. The techniques are described in the GWPDs in concise language and are accompanied by necessary figures and tables derived from cited manuals, reports, and other documents. Because a goal of this series of procedures is to remain current with the state of the science, and because procedures change over time, this report is released in an online format only. As new procedures are developed and released, they will be linked to this document.

  16. DIEP breast reconstruction following multiple abdominal liposuction procedures.

    Science.gov (United States)

    Farid, Mohammed; Nicholson, Simon; Kotwal, Ashutosh; Akali, Augustine

    2014-01-01

    Previous abdominal wall surgery is viewed as a contraindication to abdominal free tissue transfer. We present two patients who underwent multiple abdominal liposuction procedures, followed by successful free deep inferior epigastric artery perforator flap. We review the literature pertaining to reliability of abdominal free flaps in those with previous abdominal surgery. Review of case notes and radiological investigations of two patients, and a PubMed search using the terms "DIEP", "deep inferior epigastric", "TRAM", "transverse rectus abdominis", "perforator" and "laparotomy", "abdominal wall", "liposuction", "liposculpture", "fat graft", "pfannenstiel", with subsequent appraisal of relevant papers by the first and second authors. Patient 1 had 3 episodes of liposuction from the abdomen for fat grafting to a reconstructed breast. Subsequent revision reconstruction of the same breast with DIEP flap was preceded by CT angiography, which demonstrated normal perforator anatomy. The reconstruction healed well with no ischaemic complications. Patient 2 had 5 liposuction procedures from the abdomen to graft fat to a wide local excision defect. Recurrence of cancer led to mastectomy and immediate reconstruction with free DIEP flap. Preoperative MR angiography demonstrated a large perforator right of the umbilicus, with which the intraoperative findings were consistent. The patient had an uneventful recovery and good healing with no fat necrosis or wound dehiscence. We demonstrate that DIEP flaps can safely be raised without perfusion-related complications following multiple liposuction procedures to the abdomen. The safe interval between procedures is difficult to quantify, but we demonstrate successful free flap after 16 months.

  17. Procedure for Measuring and Reporting Commercial Building Energy Performance

    Energy Technology Data Exchange (ETDEWEB)

    Barley, D.; Deru, M.; Pless, S.; Torcellini, P.

    2005-10-01

    This procedure is intended to provide a standard method for measuring and characterizing the energy performance of commercial buildings. The procedure determines the energy consumption, electrical energy demand, and on-site energy production in existing commercial buildings of all types. The performance metrics determined here may be compared against benchmarks to evaluate performance and verify that performance targets have been achieved.

  18. Clinical Outcomes Following the Ross Procedure in Adults: A 25-Year Longitudinal Study.

    Science.gov (United States)

    Martin, Elisabeth; Mohammadi, Siamak; Jacques, Frederic; Kalavrouziotis, Dimitri; Voisine, Pierre; Doyle, Daniel; Perron, Jean

    2017-10-10

    Very few reports of long-term outcomes of patients who underwent the Ross procedure have been published. The authors reviewed their 25-year experience with the Ross procedure with the aim of defining very-long-term survival and factors associated with Ross-related failure. Between January 1990 and December 2014, the Ross procedure was performed in 310 adults (mean age 40.8 years) at a single institution. All patients were prospectively added to a dedicated cardiac surgery registry. Complete post-operative clinical examination and history were obtained, and transthoracic echocardiography was performed according to a standardized protocol. There was no loss to follow-up. Median follow-up was 15.1 years and up to 25 years. Bicuspid aortic valve was diagnosed in 227 patients (73.2%), and the most common indication for surgery was aortic stenosis (n = 225 [72.6%]). Freedom from any Ross-related reintervention was 92.9% and 70.1% at 10 and 20 years, respectively. Independent risk factors for pulmonary autograft degeneration were pre-operative large aortic annulus (hazard ratio: 1.1; p = 0.01), pre-operative aortic insufficiency (hazard ratio: 2.7; p = 0.002), and concomitant replacement of the ascending aorta (hazard ratio: 7.7; p = 0.0003). There were 4 hospital deaths (1.3%), and overall survival at 10 and 20 years was 94.1% and 83.6%, respectively. Long-term survival was not significantly different in patients who required Ross-related reintervention (log-rank p = 0.70). However, compared with the general population, survival was significantly lower in patients following the Ross procedure when matched on age and sex (p Ross procedure was associated with excellent long-term valvular outcomes and survival, regardless of the need for reintervention. Adults presenting with aortic insufficiency or a dilated aortic annulus or ascending aorta were at greater risk for reintervention. Unlike previous reports, long-term survival was lower in Ross

  19. Eye bank procedures: donor selection criteria.

    Science.gov (United States)

    Sousa, Sidney Júlio de Faria E; Sousa, Stella Barretto de Faria E

    2018-01-01

    Eye banks use sterile procedures to manipulate the eye, antiseptic measures for ocular surface decontamination, and rigorous criteria for donor selection to minimize the possibility of disease transmission due to corneal grafting. Donor selection focuses on analysis of medical records and specific post-mortem serological tests. To guide and standardize procedures, eye bank associations and government agencies provide lists of absolute and relative contraindications for use of the tissue based on donor health history. These lists are guardians of the Hippocratic principle "primum non nocere." However, each transplantation carries risk of transmission of potentially harmful agents to the recipient. The aim of the procedures is not to eliminate risk, but limit it to a reasonable level. The balance between safety and corneal availability needs to be maintained by exercising prudence without disproportionate rigor.

  20. Laminar resorption in modified osteo-odonto-keratoprosthesis procedure: a cause for concern.

    Science.gov (United States)

    Iyer, Geetha; Srinivasan, Bhaskar; Agarwal, Shweta; Rachapalle, Sudhir Reddi

    2014-08-01

    To analyze the cases of lamina resorption following the modified osteo-odonto-keratoprosthesis (MOOKP) procedure. Retrospective case series. Case records of 18 eyes (20 laminae) of 17 patients who showed evidence of lamina resorption out of the 85 eyes (87 laminae) of 82 patients that underwent MOOKP procedure between March 2003 and March 2013 were analyzed. Of the 17 patients (20 laminae), 1 underwent MOOKP procedure following multiple graft failures, 6 (7 laminae) belonged to the chemical injury group, and 10 (12 laminae) to the Stevens-Johnson syndrome (SJS) group. Resorption was noted in 20 out of 87 laminae (22.98%). The need for removal of lamina/extrusion was noted in 3 out of the 7 laminae in the chemical injury group and 8 out of the 12 laminae in the SJS group. The mean duration to the first sign suggestive of resorption among patients of SJS was 36.7 months and among patients of chemical injury was 43 months. Vitritis was the presenting feature (7 of 20 laminae, 35%) indicative of early resorption, and the occurrence of the same in eyes with lamina resorption was noted to be statistically significant in comparison to controls (P<.001). Sixteen out of 20 laminae showed evidence of resorption superiorly. Vitritis was the most common presenting feature of lamina resorption and could be an indicator of lamina resorption. Resorption of the laminae was noted to occur along the aspect with thinner bone support in all eyes. Incidence of severe resorption with extrusion of cylinder/requiring lamina removal was noted to be higher among patients with SJS. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Endoscopy versus radiology in post-procedural monitoring after peroral endoscopic myotomy (POEM).

    Science.gov (United States)

    Nast, Jan Friso; Berliner, Christoph; Rösch, Thomas; von Renteln, Daniel; Noder, Tania; Schachschal, Guido; Groth, Stefan; Ittrich, Harald; Kersten, Jan F; Adam, Gerhard; Werner, Yuki B

    2018-03-15

    The newly developed technique of peroral endoscopic myotomy (POEM) has been shown to be effective in several short- and mid-term studies. Limited information is available about the adequacy of immediate post-POEM monitoring tests. POEM was performed under general anesthesia in 228 patients (59.6% male, mean age 45.6 ± 15.5 years). Post-procedural checks comprised clinical and laboratory examination, and, during post-procedure days 1-5, endoscopy and-in the first 114 cases-radiologic examination using water-soluble contrast (1st group); the remaining patients underwent post-procedure controls without radiology (2nd group). Main outcome was value of endoscopic compared to radiologic control for recognition of early adverse events. In the first group, routine fluoroscopic contrast swallow suggested minor leakages at the mucosal entry site in two cases which was confirmed endoscopically in only one. Endoscopy revealed two minor entry site leakages and, in six additional cases, dislocated clips without leakage (overall 5.3%). All eight patients underwent reclipping and healed without clinical sequelae. In the 2nd group, endoscopy showed 5 clip dislocations (all reclipped) and one ischemic cardiac perforation in a patient with clinical deterioration on post-POEM day 1 who had to undergo surgery after confirmation of leakage by CT. Radiologic monitoring (contrast swallow) after POEM is not useful and can be omitted. Even routine endoscopic monitoring for detection and closure of minor defects of the mucosal entry site yields limited information with regards to final outcome; major complications are very rare and probably associated with clinical deterioration. Clinical Trials Gov Registration number of the main study: NCT01405417.

  2. American National Standard administrative practices for nuclear criticality safety, ANSI/ANS-8.19

    International Nuclear Information System (INIS)

    Smith, D.R.; Carson, R.W.

    1991-01-01

    American National Standard Administrative Practices for Nuclear Criticality Safety, ANSI/ANS-8.19, provides guidance for the administration of an effective program to control the risk of nuclear criticality in operations with fissile material outside reactors. The several sections of the standard address the responsibilities of management, supervisory personnel, and the criticality safety staff, as well as requirements and suggestions for the content of operating procedures, process evaluations, material control procedures, and emergency procedures

  3. Measuring the nose in septorhinoplasty patients: ultrasonographic standard values and clinical correlations.

    Science.gov (United States)

    Stenner, Markus; Koopmann, Mario; Rudack, Claudia

    2017-02-01

    Although septorhinoplasty is the most commonly performed operation in plastic surgery, and the surgical plan as well as its outcome is directly related to the configuration of the anatomical structures in the nose, these are not routinely assessed preoperatively. The aim of our study was to evaluate the nasal soft tissue and cartilaginous structures by means of high-resolution ultrasonography to set up clinical correlations and standard values. We examined 44 patients before septorhinoplasty by high-resolution ultrasonography in noncontact mode. All pictures were quantitatively evaluated by measuring 13 lengths and 4 ratios. All patients underwent a rhinomanometry measuring the nasal air flow. Besides others, men as well as older patients have a significantly thicker alar cartilage. Patients with thinner alar cartilages have a significantly smaller interdomal distance as well as significantly thinner upper lateral cartilages. The soft tissue above the bony dorsum was significantly thicker in older patients. Younger patients have significantly thicker soft tissue in relation to their cartilage. Patients with thicker soft tissue and thinner cartilage have a smaller tip. The interdomal distance and the thickness of the cartilaginous septum significantly correlated with the nasal air flow. We set up standard values of nasal structures in septorhinoplasty patients which can be used as reference values. By judging cartilage and soft tissue characteristics preoperatively, relevant factors for distinct procedures could be analyzed and the surgical steps can be better planned. Visualization by ultrasonography enables the surgeon to achieve treatment goals in a more predictable fashion.

  4. Report on the Observance of Standards and Codes, Accounting and Auditing : Module B - Institutional Framework for Corporate Financial Reporting, B.9 Auditing Standard-setting

    OpenAIRE

    World Bank

    2017-01-01

    The purpose of this report is to gain an understanding of the governance arrangements, procedures, and capacity for setting auditing standards in a jurisdiction, covering: (a) the adoption of International Standards on Auditing (ISA) where applicable, and (b) national auditing standards. The questions are based on examples of good practice followed by international standard-setting bodies....

  5. 10 CFR 452.5 - Bidding procedures.

    Science.gov (United States)

    2010-01-01

    ... for the reverse auction. (e) Bid evaluation and incentive awards selection procedures include the... bids, preference will be given to the lowest tied bidder based on DOE's evaluation of the extent to... feedstock suppliers. (4) In the event more than one lowest tied bid equally meets the standards in paragraph...

  6. National trends in utilization and outcomes of coronary revascularization procedures among people with and without type 2 diabetes in Spain (2001-2011).

    Science.gov (United States)

    Lopez-de-Andres, Ana; Jimenez-García, Rodrigo; Hernandez-Barrera, Valentin; Perez-Farinos, Napoleon; de Miguel-Yanes, Jose M; Mendez-Bailon, Manuel; Jimenez-Trujillo, Isabel; de Miguel, Angel Gil; Pino, Carmen Gallardo; Carrasco-Garrido, Pilar

    2014-01-03

    Diabetes is associated with a high risk of death due to coronary artery disease (CAD). People with diabetes suffering from CAD are frequently treated with revascularization procedures. We aim to compare trends in the use and outcomes of coronary revascularization procedures in diabetic and non-diabetic patients in Spain between 2001 and 2011. We identified all patients who had undergone coronary revascularization procedures, percutaneous coronary interventions (PCI) and coronary artery bypass graft (CABG) surgeries, using national hospital discharge data. Discharges were grouped by diabetes status: type 2 diabetes and no diabetes. The incidence of discharges attributed to coronary revascularization procedures were calculated stratified by diabetes status. We calculated length of stay and in-hospital mortality (IHM). We apply joinpoint log-linear regression to identify the years in which changes in tendency occurred in the use of PCI and CABG in diabetic and non-diabetic patients. Multivariate analysis was adjusted by age, sex, year and comorbidity (Charlson comorbidity index). From 2001 to 2011, 434,108 PCIs and 79,986 CABGs were performed. According to the results of the joinpoint analysis, we found that sex and age-adjusted use of PCI increased by 31.4% per year from 2001 to 2003, by 15.9% per year from 2003 to 2006 and by 3.8% per year from 2006 to 2011 in patients with diabetes. IHM among patients with diabetes who underwent a PCI did not change significantly over the entire study period (OR 0.99; 95% CI 0.97-1.00).Among patients with diabetes who underwent a CABG, the sex and age-adjusted CABG incidence rate increased by 10.4% per year from 2001 to 2003, and then decreased by 1.1% through 2011. Diabetic patients who underwent a CABG had a 0.67 (95% CI 0.63-0.71) times lower probability of dying during hospitalization than those without diabetes. The annual percent change in PCI procedures increased in diabetic and non-diabetic patients. Higher comorbidity and

  7. Procedures for the Safe Transport of Radioactive Material

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jang Lyul; Chung, K. K.; Lee, J. I.; Chang, S. Y.; Lee, T. Y

    2007-11-15

    This technical report describes the procedure and work responsibility along with the regulation and standard necessary for the safe transport of radioactive or contaminated materials. This report, therefore, can be effectively used to secure the public safety as well as to prevent the disastrous event which might be resulted from the transport process of radioactive materials by establishing a procedure and method on the safe packing, handling and transport of radioactive materials.

  8. European wind turbine testing procedure developments. Task 2: Power quality

    DEFF Research Database (Denmark)

    Sørensen, Poul Ejnar; Friis Pedersen, Troels; Gerdes, G.

    2001-01-01

    The present report describes the work done in the power quality subtask of the European Wind Turbine Testing Procedure Developments project funded by the EU SMT program. The objective of the power quality subtask has been to make recommendations andprovide background for new standards...... for measurement and testing of wind turbine power quality. The focus in the work has been to support the ongoing standardisation work in IEC with a new standard IEC61400-21 for measurement and assessment of powerquality characteristics of grid connected wind turbines. The work has also been based on the power...... quality measuremnet procedure in the Measnet cooperation of European test stations for wind turbines. The first working item of the project has been toverify the state of the art of the measurement procedures by analyses and comparisons of the measurements and data processing software of the participating...

  9. Recommendations for fluorescence instrument qualification: the new ASTM Standard Guide.

    Science.gov (United States)

    DeRose, Paul C; Resch-Genger, Ute

    2010-03-01

    Aimed at improving quality assurance and quantitation for modern fluorescence techniques, ASTM International (ASTM) is about to release a Standard Guide for Fluorescence, reviewed here. The guide's main focus is on steady state fluorometry, for which available standards and instrument characterization procedures are discussed along with their purpose, suitability, and general instructions for use. These include the most relevant instrument properties needing qualification, such as linearity and spectral responsivity of the detection system, spectral irradiance reaching the sample, wavelength accuracy, sensitivity or limit of detection for an analyte, and day-to-day performance verification. With proper consideration of method-inherent requirements and limitations, many of these procedures and standards can be adapted to other fluorescence techniques. In addition, procedures for the determination of other relevant fluorometric quantities including fluorescence quantum yields and fluorescence lifetimes are briefly introduced. The guide is a clear and concise reference geared for users of fluorescence instrumentation at all levels of experience and is intended to aid in the ongoing standardization of fluorescence measurements.

  10. [Robot-assisted Pylorus-Preserving Partial Pancreaticoduodenectomy (Kausch-Whipple Procedure)].

    Science.gov (United States)

    Aselmann, H; Egberts, J-H; Hinz, S; Jünemann, K-P; Becker, T

    2016-04-01

    The surgical treatment of pancreatic head tumours is one of the most complex procedures in general surgery. In contrast to colorectal surgery, minimally-invasive techniques are not very commonly applied in pancreatic surgery. Both the delicate dissection along peri- and retropancreatic vessels and the extrahepatic bile ducts and subsequent reconstruction are very demanding with rigid standard laparoscopic instruments. The 4-arm robotic surgery system with angled instruments, unidirectional movement of instruments with adjustable transmission, tremor elimination and a stable, surgeon-controlled 3D-HD view is a promising platform to overcome the limitations of standard laparoscopic surgery regarding precise dissection and reconstruction in pancreatic surgery. Pancreatic head resection for mixed-type IPMN of the pancreatic head. Robot-assisted, minimally-invasive pylorus-preserving pancreaticoduodenectomy (Kausch-Whipple procedure). The robotic approach is particularly suited for complex procedures such as pylorus-preserving pancreatic head resections. The fully robotic Kausch-Whipple procedure is technically feasible and safe. The advantages of the robotic system are apparent in the delicate dissection near vascular structures, in lymph node dissection, the precise dissection of the uncinate process and, especially, bile duct and pancreatic anastomosis. Georg Thieme Verlag KG Stuttgart · New York.

  11. Developing an ANSI [American National Standards Institute] standard for semitrailers used to transport radioactive materials

    International Nuclear Information System (INIS)

    Gregory, P.

    1990-01-01

    A proposed new American National Standards Institute (ANSI) standard has been prepared which establishes requirements for the design, fabrication, and maintenance of semitrailers used in the highway transport of weight-concentrated radioactive loads. A weight-concentrated load is any payload which exceeds 1,488 kilograms per lineal meter (1,000 lb/ft) over any portion of the semitrailer. The proposed standard also provides detailed procedures for in-service inspections, as well as requirements for testing and quality assurance. The standard addresses only semitrailers, excluding the tractor. Trailers already in service may be certified as complying with the standard if they meet the requirements of the standard. This standard is intended to provide guidance and acceptance criteria needed to establish a uniform minimum level of performance for the designer, manufacturer, owner, operator, and shipper. This standard is not intended to apply to special, non-routine shipments of a one-time or occasional nature which require special permitting. The background and history of the standard are traced and a summary discussion of the standard is provided in this article

  12. Recanalization strategy for chronic total occlusions with tapered and stiff-tip guidewire. The results of CTO new techniQUE for STandard procedure (CONQUEST) trial.

    Science.gov (United States)

    Mitsudo, Kazuaki; Yamashita, Takehiro; Asakura, Yasushi; Muramatsu, Toshiya; Doi, Osamu; Shibata, Yoshisato; Morino, Yoshihiro

    2008-11-01

    The success rate of percutaneous coronary intervention (PCI) for chronic total coronary occlusion (CTO) lesions varies depending on the guidewire manipulation skills of the operator. The standardization of guidewire technique is very important. A new technique with a new tapered wire (Conquest, Confianza Pro) was tested to verify effectiveness for higher initial success rates and standardization of PCI for CTO. A prospective, multicenter registry was conducted at 6 investigational sites. In the CONQUEST trial, The CTO lesions were treated by using an intermediate guidewire to cross the lesion. If it did not cross, the guidewire was changed to the Conquest guidewire. If it did not cross, "seesaw-wiring" or the "parallel-wire technique" was performed. The primary endpoint was the initial procedural success rate. A total of 110 patients representing 116 CTO lesions were treated from July 2003 through March 2004. The procedural success rate was 86.2% on the first try, and 88.8% on the second try, respectively. The guidewire success rate on the second try was 90.5% during the hospital stay; no deaths, or acute myocardial infarctions were confirmed. Two patients deteriorated into tamponade, and surgical or percutaneous drainage was performed in each patient without any sequelae. A guidewire technique in PCI for CTOs that starts with the intermediate guidewire and moves to the Confianza Pro tapered guidewire, either alone or by performing a see-saw or parallel-wire technique, can achieve a high initial success rate with an acceptably low major complication rate.

  13. Towards Standardization of Sampling Methodology for Evaluation of ...

    African Journals Online (AJOL)

    This article proposes the procedure that may be adopted for comparable, representative and cost effective, soil sampling, and thereafter explores the policy issues regarding standardization of sampling activities and analytical process as it relates to soil pollution in Nigeria. Standardized sampling and analytical data for soil ...

  14. The need for culture sensitive diagnostic procedures

    NARCIS (Netherlands)

    Zandi, Tekleh; Havenaar, Johan M.; Limburg-Okken, Annechien G.; van Es, Hans; Sidali, Salah; Kadri, Nadia; van den Brink, Wim; Kahn, Rene S.

    Objective We examine the procedural validity of a standardized instrument for the diagnosis of psychotic disorders in Morocco. Method Twenty-nine patients from Casablanca, Morocco, with a psychotic or mood disorder were examined using the Comprehensive Assessment of Symptoms and History (CASH) an

  15. 77 FR 44174 - Procedures for Safety Investigations

    Science.gov (United States)

    2012-07-27

    ... of safety investigations. The rule is intended to state clearly the Board's policy and procedures for... statutory authority, when appropriate, following standard safety investigation policies, practices, and... has adhered to the regulatory philosophy and the applicable principles of regulation as set forth in...

  16. radioactive waste disposal standards abroad

    International Nuclear Information System (INIS)

    Lu Yan; Xin Pingping; Wu Jian; Zhang Xue

    2012-01-01

    With the world focus on human health and environmental protection, the problem of radioactive waste disposal has gradually become a global issue, and the focus of attention of public. The safety of radioactive waste disposal, is not only related to human health and environmental safety, but also an important factor of affecting the sustainable development of nuclear energy. In recent years the formulation of the radioactive waste disposal standards has been generally paid attention to at home and abroad, and it has made great progress. In China, radioactive waste management standards are being improved, and there are many new standards need to be developed. The revised task of implement standards is very arduous, and there are many areas for improvement about methods and procedures of the preparation of standards. This paper studies the current situation of radioactive waste disposal standards of the International Atomic Energy Agency, USA, France, Britain, Russia, Japan, and give some corresponding recommendations of our radioactive waste disposal standards. (authors)

  17. Reproducibility in light microscopy: Maintenance, standards and SOPs.

    Science.gov (United States)

    Deagle, Rebecca C; Wee, Tse-Luen Erika; Brown, Claire M

    2017-08-01

    Light microscopy has grown to be a valuable asset in both the physical and life sciences. It is a highly quantitative method available in individual research laboratories and often centralized in core facilities. However, although quantitative microscopy is becoming a customary tool in research, it is rarely standardized. To achieve accurate quantitative microscopy data and reproducible results, three levels of standardization must be considered: (1) aspects of the microscope, (2) the sample, and (3) the detector. The accuracy of the data is only as reliable as the imaging system itself, thereby imposing the need for routine standard performance testing. Depending on the task some maintenance procedures should be performed once a month, some before each imaging session, while others conducted annually. This text should be implemented as a resource for researchers to integrate with their own standard operating procedures to ensure the highest quality quantitative microscopy data. Copyright © 2017. Published by Elsevier Ltd.

  18. Laparoscopic sentinel lymph node procedure using a combination of patent blue and radioisotope in women with cervical carcinoma.

    Science.gov (United States)

    Barranger, Emmanuel; Grahek, Dany; Cortez, Annie; Talbot, Jean Noel; Uzan, Serge; Darai, Emile

    2003-06-15

    The authors evaluated the feasibility of a laparoscopic sentinel lymph node (SN) procedure with combined radioisotopic and patent blue labeling in patients with cervical carcinoma. Thirteen women (median age, 52.5 years) with cervical carcinoma (Stage Ia2 in 1 patient, Stage Ib1 in 10 patients, Stage Ib2 in 1 patient, and Stage IIa in 1 patient) underwent a laparoscopic SN procedure using an endoscopic gamma probe after both radioactive isotope and patent blue injections. After the procedure, all patients underwent complete laparoscopic pelvic lymphadenectomy and either laparoscopic radical hysterectomy (eight patients) or the Schauta-Amreich operation (five patients). SNs (mean, 1.7 SNs per patient; range, 1-3 SNs per patient) were identified in 12 of 13 patients. A median of 10.5 pelvic lymph nodes per patient (range, 4-17 pelvic lymph nodes per patient) were removed. No lymph node involvement was detected in SNs with hematoxylin and eosin staining. Immunohistochemical studies identified four metastatic SNs in two patients, with micrometastases in two SNs from the first patient and isolated tumor cells in two SNs from the second patient. No false-negative SN results were obtained. The results of this study suggest that SN detection with a combination of radiocolloid and patent blue is feasible in patients with cervical carcinoma. The combination of laparoscopy and the SN procedure permitted minimally invasive management of early-stage disease. Copyright 2003 American Cancer Society.

  19. Flexible endoscopic procedure in children with foreign bodies in their upper gastrointestinal system

    Directory of Open Access Journals (Sweden)

    Kaan Demirören

    2014-03-01

    Full Text Available Objective: Foreign body ingestion is an important public health problem. We pointed to this subject and aimed to determine the effectiveness of flexible endoscopic procedure in this study. Methods: We evaluated retrospectively fifty children having foreign body in their upper gastrointestinal system, who underwent flexible endoscopic procedure. Results: Of the patients, mean age was 5.5 ± 4 years old (range: 0.5-16 years, 64% was female. Ingested foreign bodies were coin (58%, pin (10%, battery (6%, nail (6%, necklace (6%, safety pin (4% and sewing pin, wire hairclip, ring, button and chicken skin. In endoscopic procedure, foreign bodies were seen in upper esophagus (32%, middle esophagus (26%, lower esophagus (8%, stomach (18%, bulbus (4% and second part of duodenum (8%, but were not seen in 4% of the cases. While 94% of foreign bodies were endoscopically removed, 6% of them were pushed to stomach with gastroscope from esophagus and left for spontaneous passage. Any important complication was developed. Conclusion: Flexible endoscopic procedure is an effective and safe method for removal of gastrointestinal system foreign bodies in children.

  20. 40 CFR 131.20 - State review and revision of water quality standards.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) WATER PROGRAMS WATER QUALITY STANDARDS Procedures for Review and Revision of Water Quality Standards § 131.20 State review and revision of water quality standards. (a) State review. The State shall... reviewing applicable water quality standards and, as appropriate, modifying and adopting standards. Any...