WorldWideScience

Sample records for underwent indirect calorimetry

  1. Indirect Calorimetry in Mechanically Ventilated Patients

    DEFF Research Database (Denmark)

    Allingstrup, Matilde Jo; Kondrup, Jens; Perner, Anders

    2017-01-01

    Background and Aims: The 2 currently available indirect calorimeters, CCM Express Indirect Calorimeter (MedGraphics, St Paul, MN) and Quark RMR ICU Indirect Calorimeter (COSMED, Rome, Italy), have not been validated against a gold standard in mechanically ventilated patients. Our aim was to do so...... using a gold-standard, modified Tissot bell-spirometer method in mechanically ventilated patients who were hemodynamically, respiratory, and metabolically stable. Methods: We studied 30 patients undergoing general anesthesia and major gynecological surgery. We measured oxygen consumption ((Formula...... of 77 (167) with limits of agreement −249 to 404 kcal/d. Conclusions: The QUARK RMR ICU Indirect Calorimeter compared better with the gold standard for values of (Formula presented.) O2 and REE than did the CCM Express Indirect Calorimeter in mechanically ventilated patients who were circulatory...

  2. Indirect calorimetry: assessing animal response to heat and cold stress

    NARCIS (Netherlands)

    Gaughan, J.B.; Heetkamp, M.J.W.; Hendriks, P.

    2015-01-01

    Calorimetric thermal stress studies where indirect calorimetry is used as a tool to estimate energy expenditure have been undertaken since this technique was developed. Some examples of these studies are presented in this chapter. The measurement of gas exchange by means of an open-circuit

  3. Calorimetry

    International Nuclear Information System (INIS)

    Pope, B.

    1983-01-01

    An overall review of properties of various types of calorimeters is given, with special attention given to the challenges of high luminosity and high energy. The calorimeters described include continuous calorimeters, scintillation sampling calorimetry, gas sampling calorimetry, and liquid ionization calorimeters. Next explored are some limiting factors involved in experiments at high luminosities (or at high energies), and some examples are offered of detectors capable of operating at the highest luminosities (energies). Specific areas where substantial research and development work is needed are itemized

  4. Effect of Body Position on Energy Expenditure of Preterm Infants as Determined by Simultaneous Direct and Indirect Calorimetry.

    Science.gov (United States)

    Bell, Edward F; Johnson, Karen J; Dove, Edwin L

    2017-04-01

    Background  Indirect calorimetry is the standard method for estimating energy expenditure in clinical research. Few studies have evaluated indirect calorimetry in infants by comparing it with simultaneous direct calorimetry. Our purpose was (1) to compare the energy expenditure of preterm infants determined by these two methods, direct calorimetry and indirect calorimetry; and (2) to examine the effect of body position, supine or prone, on energy expenditure. Study Design  We measured energy expenditure by simultaneous direct (heat loss by gradient-layer calorimeter corrected for heat storage) and indirect calorimetry (whole-body oxygen consumption and carbon dioxide production) in 15 growing preterm infants during two consecutive interfeeding intervals, once in the supine position and once in the prone position. Results  The mean energy expenditure for all measurements in both positions did not differ significantly by the method used: 2.82 (standard deviation [SD] 0.42) kcal/kg/h by direct calorimetry and 2.78 (SD 0.48) kcal/kg/h by indirect calorimetry. The energy expenditure was significantly lower, by 10%, in the prone than in the supine position, whether examined by direct calorimetry (2.67 vs. 2.97 kcal/kg/h, p  Direct calorimetry and indirect calorimetry gave similar estimates of energy expenditure. Energy expenditure was 10% lower in the prone position than in the supine position. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. Calorimetry

    International Nuclear Information System (INIS)

    McDonald, J.C.

    1978-01-01

    The techniques and equipment currently employed for calorimetric dosimetry have been briefly surveyed and the status of some recent measurements presented. The problems which remain to be investigated are: the thermal defect, the suitability of A-150 plastic as a material for heavy charged particle calorimetry and calorimeter designs that are appropriate for specific radiation situations, including cryogenic calorimeters

  6. Calorimetry

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    We have divided this study of calorimetry at the SLC into five topics: physics with calorimeters, readout geometries, performance of existing detectors, calorimeter technologies, and new calorimeter designs. The first topic is a review of the Z 0 physics in which calorimetry would be important. We discuss the Monte Carlo model and the general features of the events which it generates. We consider how the physics affects the design of the electromagnetic and hadron calorimeters in energy resolution, segmentation, solid angle coverage, and general performance. The two ways of reading out a calorimeter, strips and towers, are the basis of the second topic. We discuss a model which makes quantitative comparisons of these two schemes, with particular reference to electromagnetic calorimeters. These programs should be useful in other studies of calorimeter performance as well. There are six detectors at PEP and SPEAR with calorimetric elements. The third topic is a review of their performance at present energies and an evaluation of the problems which would arise at SLC energies. The new technologies which may be mature enough for use in an SLC detector are considered as the fourth topic. Some are now being built into anti pp detectors, others are in test beam stages, and others are still bright ideas. We review ten techniques and include references for further pursuit. The last section combines the physics goals, readout schemes, and present and future techniques into sensible calorimeter designs which sharpen the issues. Six models resulted. We discuss their strengths, weaknesses, feasibility, and rough costs

  7. Indirect calorimetry in nutritional therapy. A position paper by the ICALIC study group.

    Science.gov (United States)

    Oshima, Taku; Berger, Mette M; De Waele, Elisabeth; Guttormsen, Anne Berit; Heidegger, Claudia-Paula; Hiesmayr, Michael; Singer, Pierre; Wernerman, Jan; Pichard, Claude

    2017-06-01

    This review aims to clarify the use of indirect calorimetry (IC) in nutritional therapy for critically ill and other patient populations. It features a comprehensive overview of the technical concepts, the practical application and current developments of IC. Pubmed-referenced publications were analyzed to generate an overview about the basic knowledge of IC, to describe advantages and disadvantages of the current technology, to clarify technical issues and provide pragmatic solutions for clinical practice and metabolic research. The International Multicentric Study Group for Indirect Calorimetry (ICALIC) has generated this position paper. IC can be performed in in- and out-patients, including those in the intensive care unit, to measure energy expenditure (EE). Optimal nutritional therapy, defined as energy prescription based on measured EE by IC has been associated with better clinical outcome. Equations based on simple anthropometric measurements to predict EE are inaccurate when applied to individual patients. An ongoing international academic initiative to develop a new indirect calorimeter aims at providing innovative and affordable technical solutions for many of the current limitations of IC. Indirect calorimetry is a tool of paramount importance, necessary to optimize the nutrition therapy of patients with various pathologies and conditions. Recent technical developments allow broader use of IC for in- and out-patients. Copyright © 2016 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  8. Percent relative cumulative frequency analysis in indirect calorimetry: application to studies of transgenic mice.

    Science.gov (United States)

    Riachi, Marc; Himms-Hagen, Jean; Harper, Mary-Ellen

    2004-12-01

    Indirect calorimetry is commonly used in research and clinical settings to assess characteristics of energy expenditure. Respiration chambers in indirect calorimetry allow measurements over long periods of time (e.g., hours to days) and thus the collection of large sets of data. Current methods of data analysis usually involve the extraction of only a selected small proportion of data, most commonly the data that reflects resting metabolic rate. Here, we describe a simple quantitative approach for the analysis of large data sets that is capable of detecting small differences in energy metabolism. We refer to it as the percent relative cumulative frequency (PRCF) approach and have applied it to the study of uncoupling protein-1 (UCP1) deficient and control mice. The approach involves sorting data in ascending order, calculating their cumulative frequency, and expressing the frequencies in the form of percentile curves. Results demonstrate the sensitivity of the PRCF approach for analyses of oxygen consumption (.VO2) as well as respiratory exchange ratio data. Statistical comparisons of PRCF curves are based on the 50th percentile values and curve slopes (H values). The application of the PRCF approach revealed that energy expenditure in UCP1-deficient mice housed and studied at room temperature (24 degrees C) is on average 10% lower (p lower environmental temperature, there were no differences in .VO2 between groups. The latter is likely due to augmented shivering thermogenesis in UCP1-deficient mice compared with controls. With the increased availability of murine models of metabolic disease, indirect calorimetry is increasingly used, and the PRCF approach provides a novel and powerful means for data analysis.

  9. Resting energy expenditure and body composition in children with cancer: indirect calorimetry and bioimpedance analysis

    Directory of Open Access Journals (Sweden)

    M. V. Konovalova

    2014-07-01

    Full Text Available Resting energy expenditure (REE by indirect calorimetry and body composition by bioimpedance analysis are studied in three groups of children aged 5–18 years. Group 1 (n = 181 – patients in remission of cancer, group 2 (n = 55 – children with oncology diseases receiving chemotherapy or who are in the early period after hematopoietic stem cell transplantation, group 3 (n = 63 – children with non-malignant diseases of the gastrointestinal tract. To eliminate the influence of age and gender on the intergroup comparisons, body composition parameters were expressed as standardized values (z-scores relative to a reference group of healthy Russian children (n = 138,191. Group 1 was characterized by excess fat content with intact lean body mass, and groups 2 and 3 by protein depletion, more pronounced in Group 2 with a higher percentage of body fat. All used conventional formulas (WHO, Harris–Benedict and others in groups 1 and 3 underestimated REE as compared with indirect calorimetry. A new formula for REE, giving an unbiased estimate in the group 1 was proposed: REE (kcal/day = 28.7 × BCM (kg +10.5 × Height (cm – 38.6 × Age (years – 134, where BCM – body cell mass according to bioimpedance analysis (R2 = 0.67, the standard deviation of 196 kcal/day.

  10. Ionic liquids: differential scanning calorimetry as a new indirect method for determination of vaporization enthalpies.

    Science.gov (United States)

    Verevkin, Sergey P; Emel'yanenko, Vladimir N; Zaitsau, Dzmitry H; Ralys, Ricardas V; Schick, Christoph

    2012-04-12

    Differential scanning calorimetry (DSC) has been used to measure enthalpies of synthesis reactions of the 1-alkyl-3-methylimidazolium bromide [C(n)mim][Br] ionic liquids from 1-methylimidazole and n-alkyl bromides (with n = 4, 5, 6, 7, and 8). The optimal experimental conditions have been elaborated. Enthalpies of formation of these ionic liquids in the liquid state have been determined using the DSC results according to the Hess Law. The ideal-gas enthalpies of formation of [C(n)mim][Br] were calculated using the methods of quantum chemistry. They were used together with the DSC results to derive indirectly the enthalpies of vaporization of the ionic liquids under study. In order to validate the indirect determination, the experimental vaporization enthalpy of [C(4)mim][Br] was measured by using a quartz crystal microbalance (QCM). The combination of reaction enthalpy measurements by DSC with modern high-level first-principles calculations opens valuable indirect thermochemical options to obtain values of vaporization enthalpies of ionic liquids.

  11. Comparison of a Handheld Indirect Calorimetry Device and Predictive Energy Equations Among Individuals on Maintenance Hemodialysis.

    Science.gov (United States)

    Morrow, Ellis A; Marcus, Andrea; Byham-Gray, Laura

    2017-11-01

    Practical methods for determining resting energy expenditure (REE) among individuals on maintenance hemodialysis (MHD) are needed because of the limitations of indirect calorimetry. Two disease-specific predictive energy equations (PEEs) have been developed for this metabolically complex population. The aim of this study was to compare estimated REE (eREE) by PEEs to measured REE (mREE) with a handheld indirect calorimetry device (HICD). A prospective pilot study of adults on MHD (N = 40) was conducted at 2 dialysis clinics in Houston and Texas City, Texas. mREE by an HICD was compared with eREE determined by 6 PEEs using Bland-Altman analysis with a band of acceptable agreement of ±10% of the group mean mREE. Paired t-test and the intraclass correlation coefficient were also used to compare the alternate methods of measuring REE. A priori alpha was set at P Maintenance Hemodialysis Equation-Creatinine version (MHCD-CR) was the most accurate PEE with 52.5% of values within the band of acceptable agreement, followed by the Mifflin-St. Jeor Equation and the Vilar et al. Equation at 45.0% and 42.5%, respectively. When compared with mREE by the HICD, the MHDE-CR was more accurate and precise than other PEEs evaluated; however, this must be interpreted with caution as mREE was consistently lower than eREE from all PEEs. Further research is needed to validate the MHDE-CR and other practical methods for determining REE among individuals on MHD. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  12. Assessment of Metabolic Flexibility of Old and Adult Mice Using Three Noninvasive, Indirect Calorimetry-Based Treatments

    NARCIS (Netherlands)

    Duivenvoorde, L.P.M.; Schothorst, van E.M.; Swarts, J.J.M.; Keijer, J.

    2015-01-01

    Indirect calorimetry (InCa) can potentially be used to noninvasively assess metabolic and age-related flexibility. To assess the use of InCa for this purpose, we tested the sensitivity and response stability over time of three InCa-based treatments in old versus adult mice. Diurnal patterns of

  13. Partitioning of late gestation energy expenditure in ewes using indirect calorimetry and a linear regression approach

    DEFF Research Database (Denmark)

    Kiani, Alishir; Chwalibog, André; Nielsen, Mette O

    2007-01-01

    Late gestation energy expenditure (EE(gest)) originates from energy expenditure (EE) of development of conceptus (EE(conceptus)) and EE of homeorhetic adaptation of metabolism (EE(homeorhetic)). Even though EE(gest) is relatively easy to quantify, its partitioning is problematic. In the present...... study metabolizable energy (ME) intake ranges for twin-bearing ewes were 220-440, 350- 700, 350-900 kJ per metabolic body weight (W0.75) at week seven, five, two pre-partum respectively. Indirect calorimetry and a linear regression approach were used to quantify EE(gest) and then partition to EE......(conceptus) and EE(homeorhetic). Energy expenditure of basal metabolism of the non-gravid tissues (EE(bmng)), derived from the intercept of the linear regression equation of retained energy [kJ/W0.75] and ME intake [kJ/W(0.75)], was 298 [kJ/ W0.75]. Values of the intercepts of the regression equations at week seven...

  14. Approximate time to steady state resting energy expenditure using indirect calorimetry in young, healthy adults

    Directory of Open Access Journals (Sweden)

    Collin Popp

    2016-11-01

    Full Text Available Indirect calorimetry (IC measurements to estimate resting energy expenditure (REE necessitate a stable measurement period, or steady state (SS. There is limited evidence when assessing the time to reach SS in young, healthy adults. The aims of this prospective study are to determine the approximate time to necessary reach SS using open-circuit IC and to establish the appropriate duration of SS needed to estimate REE. One hundred young, healthy participants (54 males and 46 females; age = 20.6 ± 2.1 years; body weight = 73.6 ± 16.3 kg; height 172.5 ± 9.3 cm; BMI = 24.5 ± 3.8 kg/m2 completed IC measurement for approximately 30-minutes while the volume of oxygen (VO2 and volume of carbon dioxide (VCO2 were collected. SS was defined by variations in the VO2 and VCO2 of ≤10% coefficient of variation (%CV over a period of 5- consecutive minutes. The 30-minute IC measurement was divided into six 5-minute segments, S1, S2, S3, S4, S5 and S6. The results show that SS was achieved during S2 (%CV = 6.81 ± 3.2%, and the %CV continued to met the SS criteria for the duration of the IC measurement (S3= 8.07 ± 4.4%; S4 = 7.93 ± 3.7%; S5 = 7.75 ± 4.1%; S6 = 8.60 ± 4.6%. The current study found that in a population of young, healthy adults the duration of the IC measurement period could be a minimum of 10 minutes. The first 5-minute segment was discarded, while SS occurred by the second 5-minute segment.

  15. Use of Indirect Calorimetry to Detect Overfeeding in Critically Ill Children: Finding the Appropriate Definition.

    Science.gov (United States)

    Kerklaan, Dorian; Hulst, Jessie M; Verhoeven, Jennifer J; Verbruggen, Sascha C A T; Joosten, Koen F M

    2016-10-01

    Overfeeding during critical illness is associated with adverse effects such as metabolic disturbances and increased risk of infection. Because of the lack of sound studies with clinical endpoints, overfeeding is arbitrarily defined as the ratio caloric intake/measured resting energy expenditure (mREE) or alternatively as a comparison of measured respiratory quotient (RQ) to the predicted RQ based on the macronutrient intake (RQmacr). We aimed to compare definitions of overfeeding in critically ill mechanically ventilated children based on mREE, RQ, and caloric intake to find an appropriate definition. Indirect calorimetry measurements were performed in 78 mechanically ventilated children, median age 6.3 months. Enteral and/or parenteral nutrition was provided according to the local guidelines. Definitions used to indicate overfeeding were the ratio caloric intake/mREE of >110% and >120% and by the measured RQ > RQmacr + 0.05. The proportion of patients identified as overfed varied widely depending on the definition used, ranging from 22% (RQ > RQmacr + 0.05), to 40% and 50% (caloric intake/mREE of >120% and >110%, respectively). Linear regression analysis showed that all patients would be identified as overfed with the definition RQ > RQmacr + 0.05 when the ratio caloric intake/mREE exceeded 165%. Caloric intake was higher in children with a standard deviation-score weight for age definition applied. These currently used definitions fail to take into account several relevant factors affecting metabolism during critical illness and are therefore not generally applicable to the pediatric intensive care unit population.

  16. Breath test measurements in combination with indirect calorimetry for estimation of 13C-leucine oxidation in mink (Mustela vison)

    DEFF Research Database (Denmark)

    Tauson, Anne-Helene; Ali, Abdalla; Kanska, Katarzyna

    2000-01-01

    Gas exchange measurements by means of indirect calorimetry can be used to calculate quantitative substrate oxidation. The results represents average net oxidation values (substrate disappearance rate), but they cannot describe the dynamics of the oxidation processes. Breath test measurements...... to feeding and fasting. Twelve 1-year-old male mink (Mustela vison) were measured in each five consecutive periods by means of indirect calorimetry and simultaneous breath test. In Periods 1, 3 and 5, each lasting 3 days, the animals were fed ad libitum and Periods 2 and 4 were fasting periods, each of 48 h....... In Periods 1 and 5 all animals were fed a diet with a high quality fish meal (FISH; n=12), while in Period 3 half of the animals received the FISH diet (n=6) and the other half a diet with soy protein concentrate (SOY; n=6) as main protein source. An intraperitoneal injection of 1-13C-leucine was given...

  17. Factors Associated With Protein-energy Malnutrition in Chronic Liver Disease: Analysis Using Indirect Calorimetry.

    Science.gov (United States)

    Nishikawa, Hiroki; Yoh, Kazunori; Enomoto, Hirayuki; Iwata, Yoshinori; Kishino, Kyohei; Shimono, Yoshihiro; Hasegawa, Kunihiro; Nakano, Chikage; Takata, Ryo; Nishimura, Takashi; Aizawa, Nobuhiro; Sakai, Yoshiyuki; Ikeda, Naoto; Takashima, Tomoyuki; Ishii, Akio; Iijima, Hiroko; Nishiguchi, Shuhei

    2016-01-01

    We aimed to elucidate the incidence of protein-energy malnutrition (PEM) in patients with chronic liver disease and to identify factors linked to the presence of PEM.A total of 432 patients with chronic liver disease were analyzed in the current analysis. We defined patients with serum albumin level of ≤3.5 g/dL and nonprotein respiratory quotient (npRQ) value using indirect calorimetry less than 0.85 as those with PEM. We compared between patients with PEM and those without PEM in baseline characteristics and examined factors linked to the presence of PEM using univariate and multivariate analyses.There are 216 patients with chronic hepatitis, 123 with Child-Pugh A, 80 with Child-Pugh B, and 13 with Child-Pugh C. Six patients (2.8%) had PEM in patients with chronic hepatitis, 17 (13.8%) in patients with Child-Pugh A, 42 (52.5%) in patients with Child-Pugh B, and 10 (76.9%) in patients with Child-Pugh C (P < 0.001). Multivariate analysis revealed that Child-Pugh classification (P < 0.001), age ≥64 years (P = 0.0428), aspartate aminotransferase (AST) ≥40 IU/L (P = 0.0023), and branched-chain amino acid to tyrosine ratio (BTR) ≤5.2 (P = 0.0328) were independent predictors linked to the presence of PEM. On the basis of numbers of above risk factors (age, AST, and BTR), the proportions of patients with PEM were well stratified especially in patients with early chronic hepatitis or Child-Pugh A (n = 339, P < 0.0001), while the proportions of patients with PEM tended to be well stratified in patients with Child-Pugh B or C (n = 93, P = 0.0673).Age, AST, and BTR can be useful markers for identifying PEM especially in patients with early stage of chronic liver disease.

  18. Evidence analysis library review of best practices for performing indirect calorimetry in healthy and non-critically ill individuals.

    Science.gov (United States)

    Fullmer, Susan; Benson-Davies, Sue; Earthman, Carrie P; Frankenfield, David C; Gradwell, Erica; Lee, Peggy S P; Piemonte, Tami; Trabulsi, Jillian

    2015-09-01

    When measurement of resting metabolic rate (RMR) by indirect calorimetry is necessary, following evidence-based protocols will ensure the individual has achieved a resting state. The purpose of this project was to update the best practices for measuring RMR by indirect calorimetry in healthy and non-critically ill adults and children found the Evidence Analysis Library of the Academy of Nutrition and Dietetics. The Evidence Analysis process described by the Academy of Nutrition and Dietetics was followed. The Ovid database was searched for papers published between 2003 and 2012 using key words identified by the work group and research consultants, studies used in the previous project were also considered (1980 to 2003), and references were hand searched. The work group worked in pairs to assign papers to specific questions; however, the work group developed evidence summaries, conclusion statements, and recommendations as a group. Only 43 papers were included to answer 21 questions about the best practices to ensure an individual is at rest when measuring RMR in the non-critically ill population. In summary, subjects should be fasted for at least 7 hours and rest for 30 minutes in a thermoneutral, quiet, and dimly lit room in the supine position before the test, without doing any activities, including fidgeting, reading, or listening to music. RMR can be measured at any time of the day as long as resting conditions are met. The duration of the effects of nicotine and caffeine and other stimulants is unknown, but lasts longer than 140 minutes and 240 minutes, respectively. The duration of the effects of various types of exercise on RMR is unknown. Recommendations for achieving steady state, preferred gas-collection devices, and use of respiratory quotient to detect measurement errors are also given. Of the 21 conclusions statements developed in this systemic review, only 5 received a grade I or II. One limitation is the low number of studies available to address the

  19. Effects of 2 wk of GH administration on 24-h indirect calorimetry in young, healthy, lean men

    DEFF Research Database (Denmark)

    Hansen, Mette; Morthorst, Rikke; Larsson, Benny

    2005-01-01

    The present study was designed as a randomized, double-blind placebo (Plc)-controlled study to determine the effect of 2 wk of growth hormone administration (GH-adm.) on energy expenditure (EE) and substrate oxidation in healthy humans. Sixteen young healthy men were divided into two groups....... The study consisted of two 24-h measurements (indirect calorimetry), separated by 2 wk of either Plc or GH injections (6 IU/day). At baseline, no significant differences were observed between the two groups in any of the measured anthropometric, hormonal, or metabolic parameters, neither did the parameters...... change over time in the Plc group. GH-adm. resulted in a 4.4% increase in 24-h EE (P

  20. Low validity of the Sensewear Pro3 activity monitor compared to indirect calorimetry during simulated free living in patients with osteoarthritis of the hip

    DEFF Research Database (Denmark)

    Hermann, Andreas; Ried-Larsen, Mathias; Jensen, Andreas Emil Kryger

    2014-01-01

    BACKGROUND: To validate physical activity estimates by the Sensewear Pro3 activity monitor compared with indirect calorimetry during simulated free living in patients diagnosed with osteoarthritis of the hip pre or post total hip arthroplasty. METHODS: Twenty patients diagnosed with hip osteoarth...

  1. Evaluation of Children Playing a New-Generation Motion-Sensitive Active Videogame by Accelerometry and Indirect Calorimetry.

    Science.gov (United States)

    Reading, Stacey A; Prickett, Karel

    2013-06-01

    New-generation active videogames (AVGs) use motion-capture video cameras to connect a player's arm, leg, and body movements through three-dimensional space to on-screen activity. We sought to determine if the whole-body movements required to play the AVG elicited moderate-intensity physical activity (PA) in children. A secondary aim was to examine the utility of using accelerometry to measure the activity intensity of AVG play in this age group. The PA levels of boys (n=26) and girls (n=15) 5-12 years of age were measured by triaxial accelerometry (n=25) or accelerometry and indirect calorimetry (IC) (n=16) while playing the "Kinect Adventures!" videogame for the Xbox Kinect (Microsoft(®), Redmond, WA) gaming system. The experiment simulated a typical 20-minute in-home free-play gaming session. Using 10-second recording epochs, the average (mean±standard deviation) PA intensity over 20 minutes was 4.4±0.9, 3.2±0.7, and 3.3±0.6 metabolic equivalents (METs) when estimated by IC or vertical axis (Crouter et al. intermittent lifestyle equation for vertical axis counts/10 seconds [Cva2RM]) and vector magnitude (Crouter et al. intermittent lifestyle equation for vector magnitude counts/10 seconds [Cvm2RM]) accelerometry. In total, 16.9±3.2 (IC), 10.6±4.5 (Cva2RM), and 11.1±3.9 (Cvm2RM) minutes of game playing time were at a 3 MET intensity or higher. In this study, children played the Xbox Kinect AVG at moderate-intensity PA levels. The study also showed that current accelerometry-based methods underestimated the PA of AVG play compared with IC. With proper guidance and recommendations for use, video motion-capture AVG systems could reduce sedentary screen time and increase total daily moderate PA levels for children. Further study of these AVG systems is warranted.

  2. Exploration of Energy Metabolism in the Mouse Using Indirect Calorimetry: Measurement of Daily Energy Expenditure (DEE) and Basal Metabolic Rate (BMR).

    Science.gov (United States)

    Meyer, Carola W; Reitmeir, Peter; Tschöp, Matthias H

    2015-09-01

    Current comprehensive mouse metabolic phenotyping involves studying energy balance in cohorts of mice via indirect calorimetry, which determines heat release from changes in respiratory air composition. Here, we describe the measurement of daily energy expenditure (DEE) and basal metabolic rate (BMR) in mice. These well-defined metabolic descriptors serve as meaningful first-line read-outs for metabolic phenotyping and should be reported when exploring energy expenditure in mice. For further guidance, the issue of appropriate sample sizes and the frequency of sampling of metabolic measurements is also discussed. Copyright © 2015 John Wiley & Sons, Inc.

  3. The effect of feeding on CO2 production and energy expenditure in ponies measured by indirect calorimetry and the 13C-bicarbonate technique

    DEFF Research Database (Denmark)

    Jensen, Rasmus Bovbjerg; Kyrstein, T. D.; Junghans, P

    2015-01-01

    Energy expenditure (EE) can be estimated based on respiratory gas exchange measurements, traditionally done in respiration chambers by indirect calorimetry (IC). However, the (13)C-bicarbonate technique ((13)C-BT) might be an alternative minimal invasive method for estimation of CO(2) production...... and EE in the field. In this study, four Shetland ponies were used to explore the effect of feeding on CO(2) production and EE measured simultaneously by IC and (13)C-BT. The ponies were individually housed in respiration chambers and received either a single oral or intravenous (IV) bolus dose of (13)C......-bicarbonate at the three different feeding times. Feeding time affected the CO(2) production (P

  4. On the accuracy of instantaneous gas exchange rates, energy expenditure and respiratory quotient calculations obtained from indirect whole room calorimetry

    International Nuclear Information System (INIS)

    Gribok, Andrei; Rumpler, William; Hoyt, Reed; Buller, Mark

    2013-01-01

    This paper analyzes the accuracy of metabolic rate calculations performed in the whole room indirect calorimeter using the molar balance equations. The equations are treated from the point of view of cause–effect relationship where the gaseous exchange rates representing the unknown causes need to be inferred from a known, noisy effect—gaseous concentrations. Two methods of such inference are analyzed. The first method is based on the previously published regularized deconvolution of the molar balance equation and the second one, proposed in this paper, relies on regularized differentiation of gaseous concentrations. It is found that both methods produce similar results for the absolute values of metabolic variables and their accuracy. The uncertainty for O 2 consumption rate is found to be 7% and for CO 2 production-–3.2%. The uncertainties in gaseous exchange rates do not depend on the absolute values of O 2 consumption and CO 2 production. In contrast, the absolute uncertainty in respiratory quotient is a function of the gaseous exchange rates and varies from 9.4% during the night to 2.3% during moderate exercise. The uncertainty in energy expenditure was found to be 5.9% and independent of the level of gaseous exchange. For both methods, closed form analytical formulas for confidence intervals are provided allowing quantification of uncertainty for four major metabolic variables in real world studies. (paper)

  5. On the accuracy of instantaneous gas exchange rates, energy expenditure and respiratory quotient calculations obtained from indirect whole room calorimetry.

    Science.gov (United States)

    Gribok, Andrei; Hoyt, Reed; Buller, Mark; Rumpler, William

    2013-06-01

    This paper analyzes the accuracy of metabolic rate calculations performed in the whole room indirect calorimeter using the molar balance equations. The equations are treated from the point of view of cause-effect relationship where the gaseous exchange rates representing the unknown causes need to be inferred from a known, noisy effect-gaseous concentrations. Two methods of such inference are analyzed. The first method is based on the previously published regularized deconvolution of the molar balance equation and the second one, proposed in this paper, relies on regularized differentiation of gaseous concentrations. It is found that both methods produce similar results for the absolute values of metabolic variables and their accuracy. The uncertainty for O2 consumption rate is found to be 7% and for CO2 production--3.2%. The uncertainties in gaseous exchange rates do not depend on the absolute values of O2 consumption and CO2 production. In contrast, the absolute uncertainty in respiratory quotient is a function of the gaseous exchange rates and varies from 9.4% during the night to 2.3% during moderate exercise. The uncertainty in energy expenditure was found to be 5.9% and independent of the level of gaseous exchange. For both methods, closed form analytical formulas for confidence intervals are provided allowing quantification of uncertainty for four major metabolic variables in real world studies.

  6. Basal Metabolic Rate of Adolescent Modern Pentathlon Athletes: Agreement between Indirect Calorimetry and Predictive Equations and the Correlation with Body Parameters

    Science.gov (United States)

    Loureiro, Luiz Lannes; Fonseca, Sidnei; Castro, Natalia Gomes Casanova de Oliveira e; dos Passos, Renata Baratta; Porto, Cristiana Pedrosa Melo; Pierucci, Anna Paola Trindade Rocha

    2015-01-01

    Purpose The accurate estimative of energy needs is crucial for an optimal physical performance among athletes and the basal metabolic rate (BMR) equations often are not well adjusted for adolescent athletes requiring the use of specific methods, such as the golden standard indirect calorimetry (IC). Therefore, we had the aim to analyse the agreement between the BMR of adolescents pentathletes measured by IC and estimated by commonly used predictive equations. Methods Twenty-eight athletes (17 males and 11 females) were evaluated for BMR, using IC and the predictive equations Harris and Benedict (HB), Cunningham (CUN), Henry and Rees (HR) and FAO/WHO/UNU (FAO). Body composition was obtained using DXA and sexual maturity data were retrieved through validated questionnaires. The correlations among anthropometric variables an IC were analysed by T-student test and ICC, while the agreement between IC and the predictive equations was analysed according to Bland and Altman and by survival-agreement plotting. Results The whole sample average BMR measured by IC was significantly different from the estimated by FAO (pBMR when compared with IC (T Test). When compared to the golden standard IC, using Bland and Altman, ICC and Survival-Agreement, the equations underestimated the energy needs of adolescent pentathlon athletes up to 300kcal/day. Therefore, they should be used with caution when estimating individual energy requirements in such populations. PMID:26569101

  7. Approximation of Resting Energy Expenditure in Intensive Care Unit Patients Using the SenseWear Bracelet: A Comparison With Indirect Calorimetry.

    Science.gov (United States)

    Sundström, Martin; Mehrabi, Mahboubeh; Tjäder, Inga; Rooyackers, Olav; Hammarqvist, Folke

    2017-08-01

    Indirect calorimetry (IC) is the gold standard for determining energy expenditure in patients requiring mechanical ventilation. Metabolic armbands using data derived from dermal measurements have been proposed as an alternative to IC in healthy subjects, but their utility during critical illness is unclear. The aim of this study was to determine the level of agreement between the SenseWear armband and the Deltatrac Metabolic Monitor in mechanically ventilated intensive care unit (ICU) patients. Adult ICU patients requiring invasive ventilator therapy were eligible for inclusion. Simultaneous measurements were performed with the SenseWear Armband and Deltatrac under stable conditions. Resting energy expenditure (REE) values were registered for both instruments and compared with Bland-Altman plots. Forty-two measurements were performed in 30 patients. The SenseWear Armband measured significantly higher REE values as compared with IC (mean bias, 85 kcal/24 h; P = .027). Less variability was noted between individual SenseWear measurements and REE as predicted by the Harris-Benedict equation (2 SD, ±327 kcal/24 h) than when IC was compared with SenseWear and Harris-Benedict (2 SD, ±473 and ±543 kcal/24 h, respectively). The systematic bias and large variability of the SenseWear armband when compared with gas exchange measurements confer limited benefits over the Harris Benedict equation in determining caloric requirements of ICU patients.

  8. The Net Energy Values of Corn, Dried Distillers Grains with Solubles and Wheat Bran for Laying Hens Using Indirect Calorimetry Method

    Directory of Open Access Journals (Sweden)

    D. Ning

    2014-02-01

    Full Text Available The present study was conducted to estimate the NE values of corn, dried distillers grains with solubles (DDGS and wheat bran (WB for laying hens based on an indirect calorimetry method and nitrogen balance measurements. A total of 576 twenty-eight-wk-old Dwarf Pink-shell laying hens were randomly assigned to four groups fed a basal diet (BD or a combination of BD with 50% corn or 20% DDGS or 20% WB, with four replicates each. After a 7-d adaptation period, each replicate with 36 hens were kept in one of the two respiration chambers to measure the heat production (HP for 6 days during the feeding period and subsequent 3-d fasting. The equilibrium fasting HP (FHP provided an estimate of NE requirements for maintenance (NEm. The NE values of test feedstuffs was estimated using the difference method. Results showed that the heat increment that contributed 35.34 to 37.85% of ME intake was not influenced by experimental diets (p>0.05 when expressed as Mcal/kg of DM feed intake. Lighting increased the HP in hens in an fed-state. The FHP decreased over time (p0.05. The estimated AME, AMEn, and NE values were 3.46, 3.44 and 2.25 Mcal/kg DM for corn, 3.11, 2.79, and 1.80 Mcal/kg DM for DDGS, 2.14, 2.10, and 1.14 Mcal/kg DM for WB, respectively. The net availability of AME of corn tended to be numerically higher than DDGS and WB (p = 0.096. In conclusion, compared with corn, the energy values of DDGS and WB were overestimated when expressed on an AME basis.

  9. Basal Metabolic Rate of Adolescent Modern Pentathlon Athletes: Agreement between Indirect Calorimetry and Predictive Equations and the Correlation with Body Parameters.

    Directory of Open Access Journals (Sweden)

    Luiz Lannes Loureiro

    Full Text Available The accurate estimative of energy needs is crucial for an optimal physical performance among athletes and the basal metabolic rate (BMR equations often are not well adjusted for adolescent athletes requiring the use of specific methods, such as the golden standard indirect calorimetry (IC. Therefore, we had the aim to analyse the agreement between the BMR of adolescents pentathletes measured by IC and estimated by commonly used predictive equations.Twenty-eight athletes (17 males and 11 females were evaluated for BMR, using IC and the predictive equations Harris and Benedict (HB, Cunningham (CUN, Henry and Rees (HR and FAO/WHO/UNU (FAO. Body composition was obtained using DXA and sexual maturity data were retrieved through validated questionnaires. The correlations among anthropometric variables an IC were analysed by T-student test and ICC, while the agreement between IC and the predictive equations was analysed according to Bland and Altman and by survival-agreement plotting.The whole sample average BMR measured by IC was significantly different from the estimated by FAO (p<0.05. Adjusting data by gender FAO and HR equations were statistically different from IC (p <0.05 among males, while female differed only for the HR equation (p <0.05.The FAO equation underestimated athletes' BMR when compared with IC (T Test. When compared to the golden standard IC, using Bland and Altman, ICC and Survival-Agreement, the equations underestimated the energy needs of adolescent pentathlon athletes up to 300kcal/day. Therefore, they should be used with caution when estimating individual energy requirements in such populations.

  10. The effect of feeding on CO2 production and energy expenditure in ponies measured by indirect calorimetry and the 13C-bicarbonate technique.

    Science.gov (United States)

    Jensen, R B; Kyrstein, T D; Junghans, P; Tauson, A H

    2015-11-01

    Energy expenditure (EE) can be estimated based on respiratory gas exchange measurements, traditionally done in respiration chambers by indirect calorimetry (IC). However, the (13)C-bicarbonate technique ((13)C-BT) might be an alternative minimal invasive method for estimation of CO(2) production and EE in the field. In this study, four Shetland ponies were used to explore the effect of feeding on CO(2) production and EE measured simultaneously by IC and (13)C-BT. The ponies were individually housed in respiration chambers and received either a single oral or intravenous (IV) bolus dose of (13)C-labelled sodium bicarbonate (NaH(13)CO(3)). The ponies were fed haylage 3 h before (T(-3)), simultaneously with (T(0)) or 3 h after (T(+3)) administration of (13)C-bicarbonate. The CO(2) produced and O(2) consumed by the ponies were measured for 6 h with both administration routes of (13)C-bicarbonate at the three different feeding times. Feeding time affected the CO(2) production (P<0.001) and O(2) consumption (P<0.001), but not the respiratory quotient (RQ) measured by IC. The recovery factor (RF) of (13)C in breath CO(2) was affected by feeding time (P<0.01) and three different RF were used in the calculation of CO(2) production measured by 13C-BT. An average RQ was used for the calculations of EE. There was no difference between IC and (13)C-BT for estimation of CO(2) production. An effect of feeding time (P<0.001) on the estimated EE was found, with higher EE when feed was offered (T(0) and T(+3)) compared with when no feed was available (T -3) during measurements. In conclusion, this study showed that feeding time affects the RF and measurements of CO(2) production and EE. This should be considered when the (13)C-BT is used in the field. IV administration of (13)C-bicarbonate is recommended in future studies with horses to avoid complex (13)C enrichment-time curves with maxima and shoulders as observed in several experiments with oral administration of (13)C-bicarbonate.

  11. Avaliação nutricional de pacientes com cirrose pelo vírus da hepatite C: a aplicação da calorimetria indireta Nutritional assessment in patients with cirrhosis: the use of indirect calorimetry

    Directory of Open Access Journals (Sweden)

    Catarina Bertaso Andreatta Gottschall

    2004-12-01

    .BACKGROUND: Malnutrition is frequent in cirrhotic patients, and its assessment is difficult. Functional assessment through a dynamometer is a simple method and could minimize these drawbacks. Harris-Benedict prediction formulae estimates the resting energy expenditure but has not been validated for this population. One alternative is the use of indirect calorimetry. AIM: To assess nutritional status in cirrhotic patients and estimates the resting energy expenditure through indirect calorimetry and compares it to Harris-Benedict. PATIENTS AND METHODS: Thirty four adult hepatitis C cirrhotic outpatients were studied, classified by Child-Pugh and model of end-stage liver disease score. The resting energy expenditure was predicted through Harris-Benedict and measured by indirect calorimetry. Nutritional assessment was done through anthropometry, subjective global assessment, hand-grip strength and a 3-day recall. RESULTS: Fifteen (44.2% were Child-Pug A, 12 (35.3% B and 7 (20.6% C, and 33 (97.1% had model of end-stage liver disease scores less than 20. The resting energy expenditure predicted was higher than the measured (Harris-Benedict 1404.5 ± 150.3 kcal; indirect calorimetry 1059.9 ± 309.6 kcal. The prevalence of malnutrition varied between methods (body mass index, muscle arm circumference, subjective global assessment, triceps skinfold thickness and hand-grip strength: 0; 5.9; 17.6; 35.3 and 79.4%, accordingly. Calories and proteins intake were 80% and 85% of recommended amounts and there was inadequate intake of calcium, magnesium, iron and zinc. CONCLUSION: Malnutrition was frequent and hand-grip strength seemed to be the most sensitive method for its diagnosis. Calories and protein intakes were inadequate. Considering that the predicted resting energy expenditure was higher than the measured one and the need to offer higher caloric intake, the use of the predicting equation may replace indirect calorimetry.

  12. The effect of continuous work on discretionary energy expenditure in male adult construction workers in northern Mexico as studies by the 2H218O method and indirect calorimetry

    International Nuclear Information System (INIS)

    Valencia, M.E.; Gonzalez, L.; Moya, S.Y.; Saucedo, S.; Pinelli, A.; Haggarty, P.; McNeill, G.

    1993-01-01

    Energy balance, in relation to energy needs in populations of developing countries is an important issue in terms of nutritional status, health and food policy implications. The objective of this study was to measure the variations in discretionary energy expenditure (DEE) in male adult construction workers of different body mass index (BMI), when challenged to heavy work. Twelve adult volunteers engaged in construction work, 18-30 years, BMI range 16.7 to 28.9 were selected from different low income urban sectors in northern Mexico. These individuals were subjected to a specific work load equivalent to a physical activity index (PAI) ≥ 2.1 x BMR, within a time frame of 6 hours a day, eight out of ten days. The rest of the time including one full weekend was to their discretion. Energy expenditure was measured using the 2 H 2 18 O technique. BMR and the thermic effect of food were evaluated by ventilated hood indirect calorimetry. The energy cost of fixed activities was measured by the Oxylog. A daily activity diary was kept throughout the ten days of the protocol. This study shows no evidence that individuals of different energy status in a range of BMI from 16.7 to 28.9 modify the discretionary component of their total daily expenditure to cope with the equivalent of a heavy work load (PAI ≥ 2.1) 11 refs, 1 fig., 3 tabs

  13. Energy Expenditure Evaluation in Humans and Non-Human Primates by SenseWear Armband. Validation of Energy Expenditure Evaluation by SenseWear Armband by Direct Comparison with Indirect Calorimetry

    Science.gov (United States)

    Casiraghi, Francesca; Chavez, Alberto O.; Davalli, Alberto M.; Naegelin, Terry; Comuzzie, Anthony G.; Frost, Patricia; Musi, Nicolas; Folli, Franco

    2013-01-01

    Introduction The purpose of this study was to compare and validate the use of SenseWear Armband (SWA) placed on the arm (SWA ARM) and on the back (SWA BACK) in healthy humans during resting and a cycle-ergometer exercise and to evaluate the SWA to estimate Resting Energy Expenditure (REE) and Total Energy Expenditure (TEE) in healthy baboons. Methods We studied 26 (15F/11M) human subjects wearing SWA in two different anatomical sites (arm and back) during resting and a cycle-ergometer test and directly compared these results with indirect calorimetry evaluation (IC), performed at the same time. We then inserted the SWA in a metabolic jacket for baboons and evaluated the TEE and REE in free living condition for 6 days in 21 (8F/13M) non-human primates. Results In humans we found a good correlation between SWA place on the ARM and on the BACK with IC during the resting experiment (1.1±0.3 SWAs, 1±0.2 IC kcal/min) and a slight underestimation in the SWAs data compared with IC during the cycle-ergometer exercise (5±1.9 SWA ARM, 4.5±1.5 SWA BACK and 5.4±2.1 IC kcal/min). In the non-human primate (baboons) experiment SWA estimated a TEE of 0.54±0.009 kcal/min during free living and a REE of 0.82±0.06 kcal/min. Conclusion SWA, an extremely simple and inexpensive apparatus, provides quite accurate measurements of energy expenditure in humans and in baboons. Energy expenditure data obtained with SWA are highly correlated with the data obtained with “gold standard”, IC, in humans. PMID:24069218

  14. Energy expenditure evaluation in humans and non-human primates by SenseWear Armband. Validation of energy expenditure evaluation by SenseWear Armband by direct comparison with indirect calorimetry.

    Science.gov (United States)

    Casiraghi, Francesca; Lertwattanarak, Raweewan; Luzi, Livio; Chavez, Alberto O; Davalli, Alberto M; Naegelin, Terry; Comuzzie, Anthony G; Frost, Patricia; Musi, Nicolas; Folli, Franco

    2013-01-01

    The purpose of this study was to compare and validate the use of SenseWear Armband (SWA) placed on the arm (SWA ARM) and on the back (SWA BACK) in healthy humans during resting and a cycle-ergometer exercise and to evaluate the SWA to estimate Resting Energy Expenditure (REE) and Total Energy Expenditure (TEE) in healthy baboons. We studied 26 (15F/11M) human subjects wearing SWA in two different anatomical sites (arm and back) during resting and a cycle-ergometer test and directly compared these results with indirect calorimetry evaluation (IC), performed at the same time. We then inserted the SWA in a metabolic jacket for baboons and evaluated the TEE and REE in free living condition for 6 days in 21 (8F/13M) non-human primates. In humans we found a good correlation between SWA place on the ARM and on the BACK with IC during the resting experiment (1.1±0.3 SWAs, 1±0.2 IC kcal/min) and a slight underestimation in the SWAs data compared with IC during the cycle-ergometer exercise (5±1.9 SWA ARM, 4.5±1.5 SWA BACK and 5.4±2.1 IC kcal/min). In the non-human primate (baboons) experiment SWA estimated a TEE of 0.54±0.009 kcal/min during free living and a REE of 0.82±0.06 kcal/min. SWA, an extremely simple and inexpensive apparatus, provides quite accurate measurements of energy expenditure in humans and in baboons. Energy expenditure data obtained with SWA are highly correlated with the data obtained with "gold standard", IC, in humans.

  15. Taxa metabólica de repouso de ciclistas estimada por equações e obtida por calorimetria indireta Resting metabolic rate of cyclists estimated by mathematical equations and obtained by indirect calorimetry

    Directory of Open Access Journals (Sweden)

    Paula Guedes Cocate

    2009-10-01

    Full Text Available A taxa metabólica de repouso (TMR pode ser determinada por calorimetria indireta (CI. Porém, em função da praticidade, na prática clínica na maioria das vezes esta é estimada por equações de predição, as quais foram desenvolvidas em estudos envolvendo indivíduos não atletas. Apesar de alguns autores terem indicado que tais equações não estimam adequadamente a TMR, estas têm sido bastante utilizadas para calculá-la e prescrever dietas, inclusive para atletas. O objetivo deste estudo foi comparar a TMR determinada por CI com a estimada pelas equações de Harris & Benedict (HB, Schofield, FAO/WHO/UNU e Henry & Rees (HR, em 15 homens ciclistas, de 24,4 ± 3,68 anos, apresentando índice de massa corporal de 21,97 ± 1,46kg/m² e VO2máx de 70,00 ± 5,32mL(kg.min-1. Para comparar a TMR determinada por CI e pelas equações, utilizou-se o tratamento estatístico testes t de Student (variáveis com distribuição normal e de Mann-Whitney (variáveis sem distribuição normal, considerando p The resting metabolic rate (RMR can be determined by indirect calorimetry (IC. However, the clinical estimation of this parameter has been done using mathematical equations, which were developed in studies involving non-athletes. Although some authors have indicated that such equations do not estimate correctly the RMR, they have been constantly used to estimate such parameter and to prescribe diets, including for athletes. The objective of this study was to compare the RMR determined by IC with the ones estimated using the equations proposed by Harris & Benedict (HB, Schofield, FAO/WHO/UNU and Henry & Rees (HR, in 15 male cyclists, aged 24.4±3.68 years, body mass index of 21.97±1.46 kg/m² and VO2max of 70.00±5.32 mL(kg.min-1. Student's t test (when data presented normal distribution and Mann-Whitney (when data did not present normal distribution were used to compare the RMR determined by IC and the ones estimated by the equations. Probability

  16. Theory of calorimetry

    CERN Document Server

    Zielenkiewicz, Wojciech

    2004-01-01

    The purpose of this book is to give a comprehensive description of the theoretical fundamentals of calorimetry. The considerations are based on the relations deduced from the laws and general equations of heat exchange theory and steering theory.

  17. Determinação da taxa metabólica basal em cutias, Dasyprocta azarae, por calorimetria indireta Determination of the basal metabolic rate in agoutis, Dasyprocta azarae, by indirect calorimetry

    Directory of Open Access Journals (Sweden)

    Harald F.V. Brito

    2010-06-01

    necessidade de novos estudos sobre o metabolismo de Dasyprocta azarae, sugerindo-se a realização de aferição da taxa metabólica basal e aferição simultânea da concentração sérica de testosterona, estradiol e cortisol para os três grupos.The best way to compare different organisms is the basal metabolic rate, a fundamental interrelation existent among all living beings. Direct measures of oxygen and carbon dioxide concentrations by evaluation of inspired and expired air can be used to measure metabolic rate. So, this research was done in order to measure basal and specific metabolic rates in agoutis (Dasyprocta azarae, and reexamine the scaling of basal metabolism in this species. There were used 34 adult healthy agoutis (9 non-castrated males, 9 castrated males, and 16 females, that belong to the wild animal scientific breeding facility of the Natural History Museum of the Curitiba city, State of Paraná, Brazil. After a six-hour fasting the animals were placed in special boxes under controlled temperature (22.0±1.0ºC, and submitted to measuring of the basal metabolic rate, by indirect calorimetry. It was used the Deltatrac®II metabolic monitor, usually indicated to measure carbon dioxide production (VCO2 and oxygen consumption (VO2 in human beings, by measuring variations in the concentration of VCO2 and of VO2, with a precision of 0.01%. The specific metabolic rate was calculated after determination of the basal metabolic rate and the obtained data were analyzed by inductive statistics. The hypotheses tests for comparison among samples indicated that the specific metabolic rate is higher in non-castrated males than in females and castrated males (significance of 5%, and that the specific metabolic rate of females and castrated males are equivalent (significance of 1%. In addition, analysis of the correlation of experimental points indicates that another variable beyond body size affects the metabolic rate of non-castrated males (significance of 1%, and

  18. Scintillator plate calorimetry

    International Nuclear Information System (INIS)

    Price, L.E.

    1990-01-01

    Calorimetry using scintillator plates or tiles alternated with sheets of (usually heavy) passive absorber has been proven over multiple generations of collider detectors. Recent detectors including UA1, CDF, and ZEUS have shown good results from such calorimeters. The advantages offered by scintillator calorimetry for the SSC environment, in particular, are speed (<10 nsec), excellent energy resolution, low noise, and ease of achieving compensation and hence linearity. On the negative side of the ledger can be placed the historical sensitivity of plastic scintillators to radiation damage, the possibility of nonuniform response because of light attenuation, and the presence of cracks for light collection via wavelength shifting plastic (traditionally in sheet form). This approach to calorimetry is being investigated for SSC use by a collaboration of Ames Laboratory/Iowa State University, Argonne National Laboratory, Bicron Corporation, Florida State University, Louisiana State University, University of Mississippi, Oak Ridge National Laboratory, Virginia Polytechnic Institute and State University, Westinghouse Electric Corporation, and University of Wisconsin

  19. Calorimetry for the SSC

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, H.A.; Grannis, P.D.

    1984-01-01

    The activities related to calorimetry at Snowmass took place in three main areas. These were: (1) The performance criteria for SSC calorimetry, including the requirements on hermeticity, shower containment, segmentation and time resolution. The use of calorimetric means of particle identification was studied. (2) The study of triggering methods using calorimeter energy, angle and timing information. (3) A review of a wide variety of calorimeter materials for absorber and sampling, as well as several means of obtaining the readout of the energy deposits. 48 references, 10 figures, 1 table.

  20. Calorimetry for the SSC

    International Nuclear Information System (INIS)

    Gordon, H.A.; Grannis, P.D.

    1984-01-01

    The activities related to calorimetry at Snowmass took place in three main areas. These were: (1) The performance criteria for SSC calorimetry, including the requirements on hermeticity, shower containment, segmentation and time resolution. The use of calorimetric means of particle identification was studied. (2) The study of triggering methods using calorimeter energy, angle and timing information. (3) A review of a wide variety of calorimeter materials for absorber and sampling, as well as several means of obtaining the readout of the energy deposits. 48 references, 10 figures, 1 table

  1. Calorimetry at the SSC

    International Nuclear Information System (INIS)

    Wigmans, R.

    1988-01-01

    The state of the art, and the present understanding of the basic limitations in hadron calorimetry, are briefly described. The various options for SSC calorimeters are discussed, and the R ampersand D needed for the ones that look most promising is outlined. The most promising candidates are (1) lead/scintillating fibers and (2) lead (or uranium)/TMS (or other warm liquids)

  2. Calorimetry at the SSC

    International Nuclear Information System (INIS)

    Wigmans, R.

    1987-09-01

    The state of the art, and our present understanding of the basic limitations in hadron calorimetry, are briefly described. The various options for SSC calorimeters are discussed, and the R and D needed for the ones that look most promising is outlined. 13 refs.; 8 figs

  3. Recent developments in silicon calorimetry

    International Nuclear Information System (INIS)

    Brau, J.E.

    1990-11-01

    We present a survey of some of the recent calorimeter applications of silicon detectors. The numerous attractive features of silicon detectors are summarized, with an emphasis on those aspects important to calorimetry. Several of the uses of this technology are summarized and referenced. We consider applications for electromagnetic calorimetry, hadronic calorimetry, and proposals for the SSC

  4. Scintillating-fibre calorimetry

    International Nuclear Information System (INIS)

    Livan, M.; Vercesi, V.; Wigmans, R.

    1995-01-01

    In the past decade, calorimetry based on scintillating plastic fibres as active elements was developed from a conceptual idea to a mature detector technology, which is nowadays widely applied in particle physics experiments. This development and the performance characteristics of representative calorimeters, both for the detection of electromagnetic and hadronic showers, are reviewed. We also discuss new information on shower development processes in dense matter and its application to calorimetric principles that has emerged from some very thorough studies that were performed in the framework of this development. (orig.)

  5. Laser-flash calorimetry

    International Nuclear Information System (INIS)

    Takahashi, Y.; Nakamura, J.-I.

    1982-01-01

    The heat capacity of vanadium has been measured by laser-flash calorimetry in the temperature region from 80 to 1000 K. The results are compared with available low- and high-temperature heat capacities, and revised thermodynamic values of vanadium are given. No heat-capacity anomaly has been found in the pure vanadium sample over the temperature range investigated, while a small heat-capacity discontinuity, less than 1.2 J.K -1 .mol -1 , has been observed at 220 to 230 K on the same sample but electropolished before measurement. This anomaly disappeared after annealing at 1000 K in vacuo for 1 h and is attributable to the introduction of a small amount of hydrogen during electropolishing. (author)

  6. Calorimetry and thermodynamics of living systems

    International Nuclear Information System (INIS)

    Lamprecht, Ingolf

    2003-01-01

    Calorimetry of living systems and classical thermodynamics developed in parallel, from Lavoisier's early ice calorimeter experiments on guinea pigs, followed by Dubrunfaut's macrocalorimetric research of fermentation processes and Atwater-Rosa's whole-body calorimetry on humans and domestic animals, to the introduction of the famous Tian-Calvet instrument that found entrance into so many different fields of biology. In this work, six examples of living-system calorimetry and thermodynamics are presented. These are: (i) glycolytic oscillations far off the thermodynamic equilibrium; (ii) growth and energy balances in fermenting and respiring yeast cultures; (iii) direct and indirect calorimetric monitoring of electrically stimulated reptile metabolism; (iv) biologic and climatic factors influencing the temperature constancy and distribution in the mound of a wood ant colony as an example of a complex ecological system; (v) energetic considerations on the clustering of European honeybees in winter as a means to save energy and stored food as well as for their Japanese counterparts in defending against hornet predators; and (vi) energetic and evolutionary aspects of the mass specific entropy production rate, the so-called bound dissipation or psiu-function. The examples presented here are just a very personal selection of living systems from a broad spectrum at all levels of complexity. Common for all of them is that they were investigated calorimetrically on the background of classical and irreversible thermodynamics

  7. INDIRECT CALORIMETRY DURING ULTRADISTANCE RUNNING: A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Charles L. Dumke

    2006-12-01

    Full Text Available The purpose was to determine the energy expenditure during ultradistance trail running. A portable metabolic unit was carried by a male subject for the first 64.5 km portion of the Western States 100 running race. Calibrations were done with known gases and volumes at ambient temperature, humidity and pressure (23-40.5 °C and 16-40% respectively. Altitude averaged 1692.8 ± 210 m during data collection. The male subject (36 yrs, 75 kg, VO2max of 67.0 ml·kg-1·min-1 had an average (mean ± SD heart rate of 132 ± 9 bpm, oxygen consumption of 34.0 ± 6.8 ml·kg-1·min-1, RER of 0.91 ± 0.04, and VE of 86.0 ± 14.3 L·min-1 during the 21.7 km measuring period. This represented an average of 51% VO2max and 75% heart rate maximum. Energy expenditure was 12.6 ± 2.5 kcals·min-1, or 82.7 ± 16.6 kcals·km-1 (134 ± 27 kcals·mile-1 at 68.3 ± 12.5% carbohydrate. Extrapolation of this data would result in an energy expenditure of >13,000 kcals for the 160 km race, and an exogenous carbohydrate requirement of >250 kcal·hr-1. The energy cost of running for this subject on separate, noncompetitive occasions ranged from 64.9 ± 8.5 to 74.4 ± 5.5 kcals·km-1 (105 ± 14 to 120 ± 9 kcals·mile-1. Ultradistance trail running increases energy expenditure above that of running on nonundulating terrain, which may result in underestimating energy requirements during these events and subsequent undernourishment and suboptimal performance.

  8. Calorimetry at industrial electron accelerators

    DEFF Research Database (Denmark)

    Miller, Arne; Kovacs, A.

    1985-01-01

    Calorimetry is a convenient way to measure doses at industrial electron accelerators, where high absorbed doses (1-100 kGy) are delivered at dose rates of 102-105 Gy s-1 or even higher. Water calorimeters have been used for this purpose for several years, but recently other materials such as grap......Calorimetry is a convenient way to measure doses at industrial electron accelerators, where high absorbed doses (1-100 kGy) are delivered at dose rates of 102-105 Gy s-1 or even higher. Water calorimeters have been used for this purpose for several years, but recently other materials...

  9. Calorimetry end-point predictions

    International Nuclear Information System (INIS)

    Fox, M.A.

    1981-01-01

    This paper describes a portion of the work presently in progress at Rocky Flats in the field of calorimetry. In particular, calorimetry end-point predictions are outlined. The problems associated with end-point predictions and the progress made in overcoming these obstacles are discussed. The two major problems, noise and an accurate description of the heat function, are dealt with to obtain the most accurate results. Data are taken from an actual calorimeter and are processed by means of three different noise reduction techniques. The processed data are then utilized by one to four algorithms, depending on the accuracy desired to determined the end-point

  10. Calorimetry of non-reacting systems

    CERN Document Server

    McCullough, John P

    2013-01-01

    Experimental Thermodynamics, Volume 1: Calorimetry of Non-Reacting Systems covers the heat capacity determinations for chemical substances in the solid, liquid, solution, and vapor states, at temperatures ranging from near the absolute zero to the highest at which calorimetry is feasible.This book is divided into 14 chapters. The first four chapters provide background information and general principles applicable to all types of calorimetry of non-reacting systems. The remaining 10 chapters deal with specific types of calorimetry. Most of the types of calorimetry treated are developed over a c

  11. Water calorimetry: The heat defect

    International Nuclear Information System (INIS)

    Klassen, N.V.; Ross, C.K.

    1997-01-01

    Domen developed a sealed water calorimeter at NIST to measure absorbed dose to water from ionizing radiation. This calorimeter exhibited anomalous behavior using water saturated with gas mixtures of H 2 O 2 . Using computer simulations of the radiolysis of water, the authors show that the observed behavior can be explained if, in the gas mixtures, the amount-of-substance of H 2 and of O 2 differed significantly from 50%. The authors also report the results of simulations for other dilute aqueous solutions that are used for water calorimetry--pure water, air-saturated water, and H 2 -saturated water. The production of H 2 O 2 was measured for these aqueous solutions and compared to simulations. The results indicate that water saturated with a gas mixture containing an amount-of-substance of H 2 of 50% and of O 2 of 50% is suitable for water calorimetry if the water is stirred and is in contact with a gas space of similar volume. H 2 -saturated water does not require a gas space but O 2 contamination must be guarded against. The lack of a scavenger for OH radicals in pure water means that, depending on the water purity, some pure water might require a large priming dose to remove reactive impurities. The experimental and theoretical problems associated with air-saturated water and O 2 -saturated water in water calorimeters are discussed

  12. Development of Quartz Fiber Calorimetry

    CERN Multimedia

    2002-01-01

    % RD40 \\\\ \\\\ Very Forward Calorimeters (VFCs) in LHC detectors should cover the pseudorapidity range from $\\eta$~=~2.5 to at least $\\eta$~=~5 in order to compute missing transverse energy and for jet tagging. Operation at such high rapidity requires the use of a calorimetry technique that is very radiation resistant, fast and insensitive to radioactivity (especially to neutrons). This can be accomplished through the Quartz-Calorimeter~(Q-Cal) concept of embedding silica core fibers, that resist to the Gigarad radiation level, into an absorber. In this calorimeter the shower particles produce light through the Cherenkov effect generating a signal less than 10~ns in duration. Unique to this new technology the visible energy of hadronic showers has a transverse dimension nearly an order of magnitude smaller than that in conventional calorimeters, enabling precise spatial resolution, sharper isolation cuts and better jet recognition against the minimum bias events background. Last but not least, most radioactive ...

  13. Tritium inventory measurements using calorimetry

    International Nuclear Information System (INIS)

    Kapulla, H.; Kraemer, R.; Heine, R.

    1992-01-01

    In the past calorimetry has been developed as a powerful tool in radiometrology. Calorimetric methods have been applied for the determination of activities, half lives and mean energies released during the disintegration of radioactive isotopes. The fundamental factors and relations which determine the power output of radioactive samples are presented and some basic calorimeter principles are discussed in this paper. At the Kernforschungszentrum Karlsruhe (KfK) a family of 3 calorimeters has been developed to measure the energy release from radiative waste products arising from reprocessing operations. With these calorimeters, radiative samples with sizes from a few cm 3 to 2 ·10 5 cm 3 and heat ratings ranging from a few nW to kW can be measured. After modifications of tits inner part the most sensitive calorimeter among the three calorimeters mentioned above would be best suited for measuring the tritium inventory in T-getters of the Amersham-type

  14. Ultra-Fast Hadronic Calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Denisov, Dmitri [Fermilab; Lukić, Strahinja [VINCA Inst. Nucl. Sci., Belgrade; Mokhov, Nikolai [Fermilab; Striganov, Sergei [Fermilab; Ujić, Predrag [VINCA Inst. Nucl. Sci., Belgrade

    2017-12-18

    Calorimeters for particle physics experiments with integration time of a few ns will substantially improve the capability of the experiment to resolve event pileup and to reject backgrounds. In this paper time development of hadronic showers induced by 30 and 60 GeV positive pions and 120 GeV protons is studied using Monte Carlo simulation and beam tests with a prototype of a sampling steel-scintillator hadronic calorimeter. In the beam tests, scintillator signals induced by hadronic showers in steel are sampled with a period of 0.2 ns and precisely time-aligned in order to study the average signal waveform at various locations w.r.t. the beam particle impact. Simulations of the same setup are performed using the MARS15 code. Both simulation and test beam results suggest that energy deposition in steel calorimeters develop over a time shorter than 3 ns providing opportunity for ultra-fast calorimetry. Simulation results for an "ideal" calorimeter consisting exclusively of bulk tungsten or copper are presented to establish the lower limit of the signal integration window.

  15. WA80 BGO calorimetry electronics

    International Nuclear Information System (INIS)

    Wintenberg, A.L.; Britton, C.L. Jr.; Ericson, M.N.; Maples, R.A.; Young, G.R.; Awes, T.C.

    1991-01-01

    This paper describes instrumentation designed for BGO scintillator-based calorimetry of particles covering a very wide range of energies (from less than 50 MeV to 50 GeV). The instrumentation was designed to have a measurement accuracy of 0.1% over as much of the energy range as possible so the energy resolution of BGO would be the limiting factor. Two 1.5-cm 2 photodiodes were used per 2.5 cm x 2.5 cm x 25 cm BGO crystal. Both a charge-sensitive preamplifier and a pulse processor were developed specifically for the needs of the WA80 experiment. The preamplifier was designed for high detector capacitance (100 to 700 pF), low integral and differential non-linearity and low power consumption (200 mW). The pulse processor is a time-invariant shaping amplifier with integral peak-detect-and-hold and automatic gain selection circuits. The amplifier use quasi-triangular shaping with 4 μs peaking time, and the hold circuit is gated with a fast first level trigger. The system has more than 20 bits of effective resolution when used with an external 12-bit ADC. Results from beam tests at CERN are presented. 6 refs., 5 figs., 1 tab

  16. Differential scanning calorimetry of bacteria.

    Science.gov (United States)

    Miles, C A; Mackey, B M; Parsons, S E

    1986-04-01

    Thermograms obtained by differential scanning calorimetry of a range of bacteria of different heat resistances were compared. Equations were derived to calculate the rate at which the numbers of viable organisms in a calorimeter decline as the temperature is raised at a constant rate. Vegetative bacteria scanned at 10 degrees C min-1 showed multi-peaked thermograms with four major peaks (denoted m, n, p and q) occurring in the regions 68-73, 77-84, 89-99 and 105-110 degrees C respectively. Exceptions were that peak m (the largest peak) occurred at 79-82 degrees C in Bacillus stearothermophilus and an additional peak, r, was detected in Escherichia coli at 119 degrees C. At temperatures below the main peak m there were major differences in thermograms between species. There was a direct relationship between the onset of thermal denaturation and the thermoresistance of different organisms. Heat-sensitive organisms displayed thermogram features which were absent in the more heat-resistant types. When samples were cooled to 5 degrees C and re-heated, a small endothermic peak, pr, was observed at the same temperature as p. Peaks p and pr were identified as the melting endotherms of DNA. In all vegetative organisms examined, maximum death rates, computed from published D and z values, occurred at temperatures above the onset of thermal denaturation, i.e. cell death and irreversible denaturation of cell components occurred within the same temperature range.

  17. Liquid ionization calorimetry: review and preview

    International Nuclear Information System (INIS)

    Fabjan, C.W.

    1995-01-01

    The experimental requirements at existing and planned accelerators, and new facilities for underground or space-borne experimentation have stimulated a wide-ranging R and D programme in liquid ionization calorimetry. Precision sampling calorimetry is approaching ''crystal'' energy resolution whilst their rate capabilities will be able to cope with the highest LHC luminosities. (Quasi)-homogeneous noble-liquid calorimeters are under construction or in the planning stage to address some of the most fundamental physics questions. (orig.)

  18. Calorimetry energy measurement in particle physics

    CERN Document Server

    Wigmans, Richard

    2017-01-01

    Particle physics is the science that pursues the age-old quest for the innermost structure of matter and the fundamental interactions between its constituents. Modern experiments in this field rely increasingly on calorimetry, a detection technique in which the particles of interest are absorbed in the detector. Calorimeters are very intricate instruments. Their performance characteristics depend on subtle, sometimes counter-intuitive design details. This book, written by one of the world's foremost experts, is the first comprehensive text on this topic. It provides a fundamental and systematic introduction to calorimetry. It describes the state of the art in terms of both the fundamental understanding of calorimetric particle detection, and the actual detectors that have been or are being built and operated in experiments. The last chapter discusses landmark scientific discoveries in which calorimetry has played an important role. This book summarizes and puts into perspective the work described in some 900...

  19. Study of asphaltene precipitation by Calorimetry

    DEFF Research Database (Denmark)

    Verdier, Sylvain Charles Roland; Plantier, Frédéric; Bessières, David

    2007-01-01

    Can calorimetry bring new input to the Current understanding of asphaltene precipitation? In this work, two types of precipitation were studied by means of calorimetry: addition of n-heptane into asphaltene solutions and temperature/pressure variations on a recombined live oil. The first series...... of experiments showed that weak forces determine precipitation. Indeed, isothermal titration calorimetry could not detect any clear signal although this technique can detect low-energy transitions such as liquid-liquid equilibrium and rnicellization. The second series of tests proved that precipitation caused...... by T and P variations is exothermic for this system. Furthermore, the temperature-induced precipitation is accompanied by an increase in the apparent thermal expansivity. Therefore, it seems that these two phase transitions exhibit different calorimetric behaviours and they may not be as similar...

  20. Differential scanning calorimetry (DSC) of semicrystalline polymers.

    Science.gov (United States)

    Schick, C

    2009-11-01

    Differential scanning calorimetry (DSC) is an effective analytical tool to characterize the physical properties of a polymer. DSC enables determination of melting, crystallization, and mesomorphic transition temperatures, and the corresponding enthalpy and entropy changes, and characterization of glass transition and other effects that show either changes in heat capacity or a latent heat. Calorimetry takes a special place among other methods. In addition to its simplicity and universality, the energy characteristics (heat capacity C(P) and its integral over temperature T--enthalpy H), measured via calorimetry, have a clear physical meaning even though sometimes interpretation may be difficult. With introduction of differential scanning calorimeters (DSC) in the early 1960s calorimetry became a standard tool in polymer science. The advantage of DSC compared with other calorimetric techniques lies in the broad dynamic range regarding heating and cooling rates, including isothermal and temperature-modulated operation. Today 12 orders of magnitude in scanning rate can be covered by combining different types of DSCs. Rates as low as 1 microK s(-1) are possible and at the other extreme heating and cooling at 1 MK s(-1) and higher is possible. The broad dynamic range is especially of interest for semicrystalline polymers because they are commonly far from equilibrium and phase transitions are strongly time (rate) dependent. Nevertheless, there are still several unsolved problems regarding calorimetry of polymers. I try to address a few of these, for example determination of baseline heat capacity, which is related to the problem of crystallinity determination by DSC, or the occurrence of multiple melting peaks. Possible solutions by using advanced calorimetric techniques, for example fast scanning and high frequency AC (temperature-modulated) calorimetry are discussed.

  1. Calorimetry and thermal methods in catalysis

    CERN Document Server

    Auroux, Aline

    2013-01-01

    The book is about calorimetry and thermal analysis methods, alone or linked to other techniques, as applied to the characterization of catalysts, supports and adsorbents, and to the study of catalytic reactions in various domains: air and wastewater treatment, clean and renewable energies, refining of hydrocarbons, green chemistry, hydrogen production and storage. The book is intended to fill the gap between the basic thermodynamic and kinetics concepts acquired by students during their academic formation, and the use of experimental techniques such as thermal analysis and calorimetry to answ

  2. New crystals for dual-readout calorimetry

    Czech Academy of Sciences Publication Activity Database

    Akchurin, N.; Bedeschi, F.; Cardini, A.; Carosi, R.; Ciapetti, G.; Ferrari, R.; Franchino, S.; Fraternali, M.; Gaudio, G.; Hauptman, J.; Incagli, M.; Korzhik, M.; Lacava, F.; La Rotonda, L.; Livan, M.; Meoni, E.; Nikl, Martin; Pinci, D.; Policicchio, A.; Popescu, S.; Scuri, F.; Sill, A.; Vandelli, W.; Vedda, A.; Venturelli, T.; Voena, C.; Volobouev, I.; Wigmans, R.

    2009-01-01

    Roč. 604, č. 3 (2009), s. 512-526 ISSN 0168-9002 Institutional research plan: CEZ:AV0Z10100521 Keywords : calorimetry * Cherenkov light * high-Z scintillating crystals Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.317, year: 2009

  3. Isothermal Titration Calorimetry in the Student Laboratory

    Science.gov (United States)

    Wadso, Lars; Li, Yujing; Li, Xi

    2011-01-01

    Isothermal titration calorimetry (ITC) is the measurement of the heat produced by the stepwise addition of one substance to another. It is a common experimental technique, for example, in pharmaceutical science, to measure equilibrium constants and reaction enthalpies. We describe a stirring device and an injection pump that can be used with a…

  4. Liquid argon calorimetry for the SSC

    International Nuclear Information System (INIS)

    Gordon, H.A.

    1990-01-01

    Liquid argon calorimetry is a mature technique. However, adapting it to the challenging environment of the SSC requires a large amount of R ampersand D. The advantages of the liquid argon approach are summarized and the issues being addressed by the R ampersand D program are described. 18 refs

  5. Monte Carlo studies of uranium calorimetry

    International Nuclear Information System (INIS)

    Brau, J.; Hargis, H.J.; Gabriel, T.A.; Bishop, B.L.

    1985-01-01

    Detailed Monte Carlo calculations of uranium calorimetry are presented which reveal a significant difference in the responses of liquid argon and plastic scintillator in uranium calorimeters. Due to saturation effects, neutrons from the uranium are found to contribute only weakly to the liquid argon signal. Electromagnetic sampling inefficiencies are significant and contribute substantially to compensation in both systems. 17 references

  6. Analyzing Protein Denaturation using Fast Differential Scanning Calorimetry

    NARCIS (Netherlands)

    Splinter, R.; Van Herwaarden, A.W.; Iervolino, E.; Vanden Poel, G.; Istrate, D.; Sarro, P.M.

    2012-01-01

    This paper investigates the possibility to measure protein denaturation with Fast Differential Scanning Calorimetry (FDSC). Cancer can be diagnosed by measuring protein denaturation in blood plasma using Differential Scanning Calorimetry (DSC). FDSC can reduce diagnosis time from hours to minutes,

  7. The use of calorimetry for plutonium assay

    International Nuclear Information System (INIS)

    Mason, J.A.

    1982-12-01

    Calorimetry is a technique for measuring the thermal power of heat-producing substances. The technique may be applied to the measurement of plutonium-bearing materials which evolve heat as a result of alpha and beta decay. A calorimetric measurement of the thermal power of a plutonium sample, combined with a knowledge or measurement of the plutonium isotopic mass ratios of the sample provides a convenient and accurate, non-destructive measure of the total plutonium mass of the sample. The present report provides a description, and an assessment of the calorimetry technique applied to the assay of plutonium-bearing materials. Types and characteristics of plutonium calorimeters are considered, as well as calibration and operating procedures. The instrumentation used with plutonium calorimeters is described and the use of computer control for calorimeter automation is discussed. A critical review and assessment of plutonium calorimetry literature since 1970 is presented. Both fuel element and plutonium-bearing material calorimeters are considered. The different types of plutonium calorimeters are evaluated and their relative merits are discussed. A combined calorimeter and gamma-ray measurement assay system is considered. The design principles of plutonium assay calorimeters are considered. An automatic, computer-based calorimeter control system is proposed in conjunction with a general plutonium assay calorimeter design. (author)

  8. Scintillating Fibre Calorimetry at the LHC

    CERN Multimedia

    2002-01-01

    Good electromagnetic and hadronic calorimetry will play a central role in an LHC detector. The lead/scintillating fibre calorimeter technique provides a fast signal response well matched to the LHC rate requirements. It can be made to give equal response for electrons and hadrons (compensation) with good electromagnetic and hadronic energy resolutions.\\\\ \\\\ The aim of this R&D proposal is to study in detail the aspects that are relevant for application of this type of calorimeter in an LHC environment, including its integration in a larger system of detectors, e.g.~projective geometry, radiation hardness, light detection, calibration and stability monitoring, electron/hadron separation.....

  9. Fabrication of 12% 240Pu calorimetry standards

    International Nuclear Information System (INIS)

    Long, S.M.; Hildner, S.; Gutierrez, D.; Mills, C.; Garcia, W.; Gurule, C.

    1995-01-01

    Throughout the DOE complex, laboratories are performing calorimetric assays on items containing high burnup plutonium. These materials contain higher isotopic range and higher wattages than materials previously encountered in vault holdings. Currently, measurement control standards have been limited to utilizing 6% 240 Pu standards. The lower isotopic and wattage value standards do not complement the measurement of the higher burnup material. Participants of the Calorimetry Exchange (CALEX) Program have identified the need for new calorimetric assay standards with a higher wattage and isotopic range. This paper describes the fabrication and verification measurements of the new CALEX standard containing 12% 240 Pu oxide with a wattage of about 6 to 8 watts

  10. A guide to automation techniques in calorimetry

    International Nuclear Information System (INIS)

    Renz, D.P.; Wetzel, J.R.; Breakall, K.L.; James, S.J.; Kasperski, P.W.

    1992-01-01

    Many improvements occurring in calorimetry measurement technology in the past few years will help current users of calorimeters to achieve better use of their existing systems. These include a more user friendly operator computer interface, a more detailed printout at the end of each run, improved data processing to eliminate operator error, and improved system monitoring to detect system or environmental problems. In addition, an electrical calibration heater has been developed to replace plutonium-238 heat standards for calibrating calorimeters, and several automation systems allow for easier and safer system operation

  11. Isothermal calorimetry of enzymatic biodiesel reaction

    DEFF Research Database (Denmark)

    Fjerbæk Søtoft, Lene; Westh, Peter; Christensen, Knud Villy

    2010-01-01

      Isothermal calorimetry ITC has been used to investigate enzymatic biodiesel production. The transesterification of rapeseed oil with methanol and ethanol was catalyzed by the immobilized lipase Novozym 435 at 40°C. The ITC-experiments clearly demonstrate the possibilities of investigating complex...... and composition change in the system, the heat of reaction at 40°C for the two systems has been determined to -9.8 ± 0.9 kJ/mole biodiesel formed from rapeseed oil and methanol, and - 9.3 ± 0.7 kJ/mole when rapeseed oil and ethanol is used....

  12. Development of Resistive Micromegas for Sampling Calorimetry

    Science.gov (United States)

    Geralis, T.; Fanourakis, G.; Kalamaris, A.; Nikas, D.; Psallidas, A.; Chefdeville, M.; Karyotakis, I.; Koletsou, I.; Titov, M.

    2018-02-01

    Resistive micromegas is proposed as an active element for sampling calorimetry. Future linear collider experiments or the HL-LHC experiments can profit from those developments for Particle Flow Calorimetry. Micromegas possesses remarkable properties concerning gain stability, reduced ion feedback, response linearity, adaptable sensitive element granularity, fast response and high rate capability. Recent developments on Micromegas with a protective resistive layer present excellent results, resolving the problem of discharges caused by local high charge deposition, thanks to its RC-slowed charge evacuation. Higher resistivity though, may cause loss of the response linearity at high rates. We have scanned a wide range of resistivities and performed laboratory tests with X-rays that demonstrate excellent response linearity up to rates of (a few) times 10MHz/cm2, with simultaneous mitigation of discharges. Beam test studies at SPS/CERN with hadrons have also shown a remarkable stability of the resistive Micromegas and low currents for rates up to 15MHz/cm2. We present results from the aforementioned studies confronted with MC simulation

  13. VO2sim 0.1: Using Simulation to Understand Measurement Error in Indirect Calorimetry

    Science.gov (United States)

    2015-08-01

    RDRL CIO LL IMAL HRA MAIL & RECORDS MGMT 1 GOVT PRINTG OFC (PDF) A MALHOTRA 1 ARMY RSCH LAB – HRED (PDF) RDRL HRM D T DAVIS...GREELEY RD FORT SAM HOUSTON TX 78234-5002 1 ARMY RSCH LAB – HRED (PDF) RDRL HRM DG K GUNN BLDG 333 PICATINNY ARSENAL NJ...07806-5000 1 ARMY RSCH LAB – HRED (PDF) ARMC FIELD ELEMENT RDRL HRM CH C BURNS THIRD AVE BLDG 1467B RM 336 FORT KNOX KY 40121

  14. Energy metabolism of overweight women before, during and after weight reduction, assessed by indirect calorimetry

    NARCIS (Netherlands)

    Groot, de C.P.G.M.

    1988-01-01

    Previous studies had suggested that periods of low energy intake evoke compensatory adaptations in energy metabolism, which retard weight loss, and promote weight regain when energy intake returns to normal. The aim of this thesis was to investigate whether a slimming (low-energy) diet based on

  15. Walking for Health in Pregnancy: Assessment by Indirect Calorimetry and Accelerometry

    Science.gov (United States)

    DiNallo, Jennifer M.; Le Masurier, Guy C.; Williams, Nancy I.; Downs, Danielle Symons

    2008-01-01

    The purpose of this study was to examine RT3 accelerometer activity counts and activity energy expenditure of 36 pregnant women at 20 and 32 weeks' gestation during treadmill walking and free-living conditions. During treadmill walking, oxygen consumption was collected, and activity energy expenditure was estimated for a 30-min walk at a…

  16. Characterization of pitches by differential scanning calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Ehrburger, P.; Martin, C.; Lahaye, J.; Saint-Romain, J.L.; Couderc, P.

    1988-12-01

    Pitch materials have generally a very complex composition with molecular mass ranging from a few hundred to several thousands units. In order to characterize these materials their properties related to the glassy transformation, in particular to enthalpy relaxation, have been investigated. Solvent soluble fractions have been characterized by differential scanning calorimetry (DSC). As with polymeric materials, enthalpy relaxation can provide information about pitches and the interactions occurring between the different types of molecules present in the pitch: mean molecular size, structural factor, molecular-size distribution. The determination of glass transition properties provides a useful means for the characterization of pitch and of their solvent extracts. It also permits insight into the complex reactions which occur when pitch materials are heat-treated. 7 refs., 2 figs., 3 tabs.

  17. Synergies between electromagnetic calorimetry and PET

    International Nuclear Information System (INIS)

    Moses, William W.

    2002-01-01

    The instrumentation used for the nuclear medical imaging technique of Positron Emission Tomography (PET) shares many features with the instrumentation used for electromagnetic calorimetry. Both fields can certainly benefit from technical advances in many common areas, and this paper discusses both the commonalties and the differences between the instrumentation needs for the two fields. The overall aim is to identify where synergistic development opportunities exist. While such opportunities exist in inorganic scintillators, photodetectors, amplification and readout electronics, and high-speed computing, it is important to recognize that while the requirements of the two fields are similar, they are not identical, and so it is unlikely that advances specific to one field can be transferred without modification to the other

  18. Silicon calorimetry for the SSC[ Superconducting Supercollider

    International Nuclear Information System (INIS)

    Bertrand, C.; Borchi, E.; Brau, J.E.

    1989-01-01

    SSC experiments will rely heavily on their calorimeters. Silicon calorimetry, which has been introduced in recent years as a useful technology, has many attractive characteristics which may make it a viable option for consideration. The many attractive properties of silicon detectors are reviewed. The relevant present day applications of large areas of silicon detectors are summarize to illustrate the emerging use. The troublesome issue of radiation damage in a high luminosity environment like the SSC is considered with a summary of much of the recent new measurements which help clarify this situation. A discussion of the electronics and a possible mechanical configuration is presented, followed by a summary of the outstanding R and D issues. 31 refs., 11 figs., 3 tabs

  19. Isothermal calorimetry on enzymatic biodiesel production

    DEFF Research Database (Denmark)

    Fjerbæk, Lene

    2008-01-01

    information about effects taking place when using lipases immobilized on an inert carrier for transesterification of a triglyceride and an alcohol as for biodiesel production. The biodiesel is produced by rapeseed oil and methanol as well as ethanol and a commercial biocatalyst Novozym 435 from Novozymes...... containing a Candida Antarctica B lipase immobilized on an acrylic resin. The reaction investigated is characterized by immiscible liquids (oil, methanol, glycerol and biodiesel) and enzymes imm. on an inert carrier during reaction, which allows several effects to take place that during normal reaction...... conditions can not be elucidated. These effects have been observed with isothermal calorimetry bringing forth new information about the reaction of enzymes catalyzing transesterification. Enzymatic biodiesel production has until now not been investigated with isothermal microcalorimetry, but the results...

  20. CMS Forward Calorimetry R&D

    Energy Technology Data Exchange (ETDEWEB)

    Bilki, Burak [Univ. of Iowa, Iowa City, IA (United States); Argonne National Lab. (ANL), Argonne, IL (United States)

    2013-11-11

    This is a technical scope of work (TSW) between the Fermi National Accelerator Laboratory (Fermilab) and the experimenters of the CMS Forward Calorimetry Taskforce (FCAL group) who have committed to participate in beam tests to be carried out during the 2013-2016 Fermilab Test Beam Facility program. The TSW is intended primarily for the purpose of recording expectations for budget estimates and work allocations for Fermilab, the funding agencies and the participating institutions. It reflects an arrangement that currently is satisfactory to the parties; however, it is recognized and anticipated that changing circumstances of the evolving research program will necessitate revisions. The parties agree to modify this scope of work to reflect such required adjustments. Actual contractual obligations will be set forth in separate documents.

  1. Differential scanning calorimetry techniques: applications in biology and nanoscience.

    Science.gov (United States)

    Gill, Pooria; Moghadam, Tahereh Tohidi; Ranjbar, Bijan

    2010-12-01

    This paper reviews the best-known differential scanning calorimetries (DSCs), such as conventional DSC, microelectromechanical systems-DSC, infrared-heated DSC, modulated-temperature DSC, gas flow-modulated DSC, parallel-nano DSC, pressure perturbation calorimetry, self-reference DSC, and high-performance DSC. Also, we describe here the most extensive applications of DSC in biology and nanoscience.

  2. Differential Scanning Calorimetry Techniques: Applications in Biology and Nanoscience

    OpenAIRE

    Gill, Pooria; Moghadam, Tahereh Tohidi; Ranjbar, Bijan

    2010-01-01

    This paper reviews the best-known differential scanning calorimetries (DSCs), such as conventional DSC, microelectromechanical systems-DSC, infrared-heated DSC, modulated-temperature DSC, gas flow-modulated DSC, parallel-nano DSC, pressure perturbation calorimetry, self-reference DSC, and high-performance DSC. Also, we describe here the most extensive applications of DSC in biology and nanoscience.

  3. Current status of tritium calorimetry at TLK

    Energy Technology Data Exchange (ETDEWEB)

    Buekki-Deme, A.; Alecu, C.G.; Kloppe, B.; Bornschein, B. [Institute of Technical Physics, Tritium Laboratory Karsruhe - TLK, Karlsruhe Institute of Technology - KIT, Karlsruhe (Germany)

    2015-03-15

    Inside a tritium facility, calorimetry is an important analytical method as it is the only reference method for accountancy (it is based on the measurement of the heat generated by the radioactive decay). Presently, at Tritium Laboratory Karlsruhe (TLK), 4 calorimeters are in operation, one of isothermal type and three of inertial guidance control type (IGC). The volume of the calorimeters varies between 0.5 and 20.6 liters. About two years ago we started an extensive work to improve our calorimeters with regard to reliability and precision. We were forced to upgrade 3 of our 4 calorimeters due to the outdated interfaces and software. This work involved creating new LabView programs driving the devices, re-tuning control loops and replacing obsolete hardware components. In this paper we give a review on the current performance of our calorimeters, comparing it to recently available devices from the market and in the literature. We also show some ideas for a next generation calorimeter based on experiences with our IGC calorimeters and other devices reported in the literature. (authors)

  4. Current status of tritium calorimetry at TLK

    International Nuclear Information System (INIS)

    Buekki-Deme, A.; Alecu, C.G.; Kloppe, B.; Bornschein, B.

    2015-01-01

    Inside a tritium facility, calorimetry is an important analytical method as it is the only reference method for accountancy (it is based on the measurement of the heat generated by the radioactive decay). Presently, at Tritium Laboratory Karlsruhe (TLK), 4 calorimeters are in operation, one of isothermal type and three of inertial guidance control type (IGC). The volume of the calorimeters varies between 0.5 and 20.6 liters. About two years ago we started an extensive work to improve our calorimeters with regard to reliability and precision. We were forced to upgrade 3 of our 4 calorimeters due to the outdated interfaces and software. This work involved creating new LabView programs driving the devices, re-tuning control loops and replacing obsolete hardware components. In this paper we give a review on the current performance of our calorimeters, comparing it to recently available devices from the market and in the literature. We also show some ideas for a next generation calorimeter based on experiences with our IGC calorimeters and other devices reported in the literature. (authors)

  5. Megarectumsigma underwent surgery for chronic faecal impact action

    International Nuclear Information System (INIS)

    Canessa, C.; Gomez del Valle, M.; Caraballo, M.

    2002-01-01

    Seven patients with megarectumsigma underwent surgery for chronic faecal impaction,reviewing clinical diagnosis, aetiology and medical and surgical management.It is suggested medical management of chronic faecal impaction trying to achieve elective surgery.The curative surgery should include the resection of all pathologic bowel, but in Duhamel procedure and its modifications distal rectal tran section should be at the peritoneal reflection.Habr-Gama modification has shown to be technically easier and it has been communicated good functional results.Local unfavourable conditions may be resolve by staged surgery,which allows outline definitive bowel reconstruction after functional assessment

  6. Indirection and computer security.

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Michael J.

    2011-09-01

    The discipline of computer science is built on indirection. David Wheeler famously said, 'All problems in computer science can be solved by another layer of indirection. But that usually will create another problem'. We propose that every computer security vulnerability is yet another problem created by the indirections in system designs and that focusing on the indirections involved is a better way to design, evaluate, and compare security solutions. We are not proposing that indirection be avoided when solving problems, but that understanding the relationships between indirections and vulnerabilities is key to securing computer systems. Using this perspective, we analyze common vulnerabilities that plague our computer systems, consider the effectiveness of currently available security solutions, and propose several new security solutions.

  7. The CLEO-III Trigger: Calorimetry and tracking

    International Nuclear Information System (INIS)

    Bergfeld, T.J.; Gollin, G.D.; Haney, M.J.

    1996-01-01

    The CLEO-III Trigger provides a trigger decision every 42ns, with a latency of approximately 2.5μs. This paper describes the pipelined signal processing and pattern recognition schemes used by the calorimeter, and the axial and stereo portions of the drift chamber, to provide the information necessary to make these decisions. Field programmable gate arrays are used extensively to provide cluster filtering and location sorting for calorimetry, and path finding for tracking. Analog processing is also employed in the calorimetry to provide additional leverage on the problem. Timing information is extracted from both calorimetry and tracking

  8. Forward calorimetry in the upgraded UA1 experiment

    International Nuclear Information System (INIS)

    Alvarez-Taviel, F.J.; Diez-Hedo, F.; Doncel, P.; Marquina, M.A.; Rodrigo, T.; Bacci, C.; Petrolo, E.; Tusi, A.; Ferrando, A.; Givernaud, A.; Rubbia, C.; Vuillemin, V.

    1989-01-01

    The major improvement in the upgraded UA1 calorimetry at the Santi ppS is the general use of ionization chambers filled with tetramethylpentane (TMP) as a detection medium interspersed with uranium plates as absorber. To achieve overall uniformity of detection down to very small angles, an identical solution is proposed for the forward calorimetry. Forward calorimetry is essential for good total and missing energy measurement at high luminosity in view of the increasing rate of multiple collisions. Both designs for forward and very forward calorimeters are presented along with expected resolutions. (orig.)

  9. ALGORITHM FOR MANAGEMENT OF HYPERTENSIVE PATIENTS UNDERWENT UROLOGY INTERVENTIONS

    Directory of Open Access Journals (Sweden)

    S. S. Davydova

    2013-01-01

    Full Text Available Aim. To study the efficacy of cardiovascular non-invasive complex assessment and pre-operative preparation in hypertensive patients needed in surgical treatment of urology dis- eases.Material and methods. Males (n=883, aged 40 to 80 years were included into the study. The main group consisted of patients that underwent laparotomic nephrectomy (LTN group; n=96 and patients who underwent laparoscopic nephrectomy (LSN group; n=53. Dynamics of ambulatory blood pressure monitoring (ABPM data was analyzed in these groups in the immediate postoperative period. The efficacy of a package of non-invasive methods for cardiovascular system assessment was studied. ABPM was performed after nephrectomy (2-nd and 10-th days after surgery in patients with complaints of vertigo episodes or intense general weakness to correct treatment.Results. In LTN group hypotension episodes or blood pressure (BP elevations were observed in 20 (20.8% and 22 (22.9% patients, respectively, on the 2-nd day after the operation. These complications required antihypertensive treatment correction. Patients with hypotension episodes were significantly older than patients with BP elevation and had significantly lower levels of 24-hour systolic BP, night diastolic BP and minimal night systolic BP. Re-adjustment of antihypertensive treatment on the 10-th postoperative day was required to 2 (10% patients with hypotension episodes and to 1 (4.5% patient with BP elevation. Correction of antihypertensive therapy was required to all patients in LSN group on the day 2, and to 32 (60.4% patients on the 10-th day after the operation. Reduction in the incidence of complications (from 1.2% in 2009 to 0.3% in 2011, p<0.001 was observed during the application of cardiovascular non-invasive complex assessment and preoperative preparation in hypertensive patients.Conclusion. The elaborated management algorithm for patients with concomitant hypertension is recommended to reduce the cardiovascular

  10. ALGORITHM FOR MANAGEMENT OF HYPERTENSIVE PATIENTS UNDERWENT UROLOGY INTERVENTIONS

    Directory of Open Access Journals (Sweden)

    S. S. Davydova

    2015-09-01

    Full Text Available Aim. To study the efficacy of cardiovascular non-invasive complex assessment and pre-operative preparation in hypertensive patients needed in surgical treatment of urology dis- eases.Material and methods. Males (n=883, aged 40 to 80 years were included into the study. The main group consisted of patients that underwent laparotomic nephrectomy (LTN group; n=96 and patients who underwent laparoscopic nephrectomy (LSN group; n=53. Dynamics of ambulatory blood pressure monitoring (ABPM data was analyzed in these groups in the immediate postoperative period. The efficacy of a package of non-invasive methods for cardiovascular system assessment was studied. ABPM was performed after nephrectomy (2-nd and 10-th days after surgery in patients with complaints of vertigo episodes or intense general weakness to correct treatment.Results. In LTN group hypotension episodes or blood pressure (BP elevations were observed in 20 (20.8% and 22 (22.9% patients, respectively, on the 2-nd day after the operation. These complications required antihypertensive treatment correction. Patients with hypotension episodes were significantly older than patients with BP elevation and had significantly lower levels of 24-hour systolic BP, night diastolic BP and minimal night systolic BP. Re-adjustment of antihypertensive treatment on the 10-th postoperative day was required to 2 (10% patients with hypotension episodes and to 1 (4.5% patient with BP elevation. Correction of antihypertensive therapy was required to all patients in LSN group on the day 2, and to 32 (60.4% patients on the 10-th day after the operation. Reduction in the incidence of complications (from 1.2% in 2009 to 0.3% in 2011, p<0.001 was observed during the application of cardiovascular non-invasive complex assessment and preoperative preparation in hypertensive patients.Conclusion. The elaborated management algorithm for patients with concomitant hypertension is recommended to reduce the cardiovascular

  11. Continuing Studies on Lead/Scintillating Fibres Calorimetry (LFC)

    CERN Multimedia

    2002-01-01

    Starting from the results obtained in the framework of the LAA Project~2B, we propose a continuation of the R&D on lead/scintillating fibres calorimetry (``spaghetti calorimetry''), including further tests on the old calorimeter prototypes and the construction and testing of new prototypes. The main results we pursue concern the performances of a projective calorimeter built with new, cheaper, techniques and the radiation hardness of the scintillating fibres, the optimization of a preshower detector system is also studied.

  12. Intraoperative seizures and seizures outcome in patients underwent awake craniotomy.

    Science.gov (United States)

    Yuan, Yang; Peizhi, Zhou; Xiang, Wang; Yanhui, Liu; Ruofei, Liang; Shu, Jiang; Qing, Mao

    2016-11-25

    Awake craniotomies (AC) could reduce neurological deficits compared with patients under general anesthesia, however, intraoperative seizure is a major reason causing awake surgery failure. The purpose of the study was to give a comprehensive overview the published articles focused on seizure incidence in awake craniotomy. Bibliographic searches of the EMBASE, MEDLINE,were performed to identify articles and conference abstracts that investigated the intraoperative seizure frequency of patients underwent AC. Twenty-five studies were included in this meta-analysis. Among the 25 included studies, one was randomized controlled trials and 5 of them were comparable studies. The pooled data suggested the general intraoperative seizure(IOS) rate for patients with AC was 8%(fixed effect model), sub-group analysis identified IOS rate for glioma patients was 8% and low grade patients was 10%. The pooled data showed early seizure rates of AC patients was 11% and late seizure rates was 35%. This systematic review and meta-analysis shows that awake craniotomy is a safe technique with relatively low intraoperative seizure occurrence. However, few RCTs were available, and the acquisition of further evidence through high-quality RCTs is highly recommended.

  13. Measurement of the enthalpies of vaporization and sublimation of solids aromatic hydrocarbons by differential scanning calorimetry

    International Nuclear Information System (INIS)

    Rojas, Aaron; Orozco, Eulogio

    2003-01-01

    An experimental procedure is proposed for direct measurement of the heat involved in the vaporization of a solid organic compound above its normal melting temperature. This technique consists on the fusion of a solid aromatic hydrocarbon, which is then vaporized by a sudden decrease of the pressure. The direct register of heat flow as function of time by differential scanning calorimetry allows the quantifying of the enthalpy of vaporization of compounds such as phenanthrene, β-naphthol, pyrene, and anthracene. Enthalpies of vaporization were measured in an isothermal mode over a range of temperatures from 10 to 20 K above the melting temperatures of each compound, while enthalpies of fusion were determined from separate experiments performed in a scanning mode. Enthalpies of sublimation are computed from results of fusion and vaporization, and then compared with results from the literature, which currently are obtained by calorimetric or indirect techniques

  14. Liquid Argon Calorimetry with LHC-Performance Specifications

    CERN Multimedia

    2002-01-01

    % RD-3 Liquid Argon Calorimetry with LHC-Performance Specifications \\\\ \\\\Good electromagnetic and hadronic calorimetry will play a central role in an LHC detector. Among the techniques used so far, or under development, the liquid argon sampling calorimetry offers high radiation resistence, good energy resolution (electromagnetic and hadronic), excellent calibration stability and response uniformity. Its rate capabilities, however, do not yet match the requirements for LHC. \\\\ \\\\The aim of this proposal is to improve the technique in such a way that high granularity, good hermiticity and adequate rate capabilities are obtained, without compromising the above mentioned properties. To reach this goal, we propose to use a novel structure, the $^{\\prime\\prime}$accordion$^{\\prime\\prime}$, coupled to fast preamplifiers working at liquid argon temperature. Converter and readout electrodes are no longer planar and perpendicular to particles, as usual, but instead they are wiggled around a plane containing particles. ...

  15. Fast sampling calorimetry with solid argon ionization chambers

    International Nuclear Information System (INIS)

    Clark, E.; Linn, S.; Piekarz, H.; Wahl, H.; Womersley, J.; Hansen, S.; Hurh, P.; Rivetta, C.; Sanders, R.; Schmitt, R.; Stanek, R.; Stefanik, A.

    1992-01-01

    A proposal for the fast sampling calorimetry with solid argon as active medium and the preliminary results from the solid argon test cell are presented. The proposed test calorimeter module structure, the signal routing and the mechanical and cryogenic arrangements are also discussed

  16. Optimization of crystals for applications in dual-readout calorimetry

    Czech Academy of Sciences Publication Activity Database

    Akchurin, N.; Bedeschi, F.; Cardini, A.; Carosi, R.; Ciapetti, G.; Fasoli, M.; Ferrari, R.; Franchino, S.; Fraternali, M.; Gaudio, G.; Hauptman, J.; Incagli, M.; Lacava, F.; La Rotonda, L.; Lee, S.; Livan, M.; Meoni, E.; Nikl, Martin; Pinci, D.; Policicchio, A.; Popescu, S.; Scuri, F.; Sill, A.; Susinno, G.; Vandelli, W.; Vedda, A.; Venturelli, T.; Voena, C.; Volobouev, I.; Wigmans, R.

    2010-01-01

    Roč. 621, 1-3 (2010), 212-221 ISSN 0168-9002 Institutional research plan: CEZ:AV0Z10100521 Keywords : calorimetry * Cherenkov light * High-Z scintillating crystals Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.142, year: 2010

  17. Isothermal Titration Calorimetry Can Provide Critical Thinking Opportunities

    Science.gov (United States)

    Moore, Dale E.; Goode, David R.; Seney, Caryn S.; Boatwright, Jennifer M.

    2016-01-01

    College chemistry faculties might not have considered including isothermal titration calorimetry (ITC) in their majors' curriculum because experimental data from this instrumental method are often analyzed via automation (software). However, the software-based data analysis can be replaced with a spreadsheet-based analysis that is readily…

  18. Hadronic shower development in iron-scintillator tile calorimetry

    Czech Academy of Sciences Publication Activity Database

    Amaral, P.; Amorim, A.; Anderson, K.; Lokajíček, Miloš; Němeček, Stanislav

    2000-01-01

    Roč. 443, - (2000), s. 51-70 ISSN 0168-9002 R&D Projects: GA MPO RP-4210/69 Institutional research plan: CEZ:AV0Z1010920 Keywords : ATLAS Iron-Scintillator * hadron calorimeter * shower parametrisation * calorimetry * computer data analysis Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.964, year: 2000

  19. Particle flow calorimetry at the international linear collider

    Indian Academy of Sciences (India)

    Particle flow calorimetry at the international linear ... It is widely believed that the most promising strategy for achieving a jet ... this level of performance for two main reasons. Firstly ... (i) Tracking: For the studies presented in this paper, the track pattern ... that particles propagating outward from the interaction region will cross ...

  20. Differential Binding Models for Direct and Reverse Isothermal Titration Calorimetry.

    Science.gov (United States)

    Herrera, Isaac; Winnik, Mitchell A

    2016-03-10

    Isothermal titration calorimetry (ITC) is a technique to measure the stoichiometry and thermodynamics from binding experiments. Identifying an appropriate mathematical model to evaluate titration curves of receptors with multiple sites is challenging, particularly when the stoichiometry or binding mechanism is not available. In a recent theoretical study, we presented a differential binding model (DBM) to study calorimetry titrations independently of the interaction among the binding sites (Herrera, I.; Winnik, M. A. J. Phys. Chem. B 2013, 117, 8659-8672). Here, we build upon our DBM and show its practical application to evaluate calorimetry titrations of receptors with multiple sites independently of the titration direction. Specifically, we present a set of ordinary differential equations (ODEs) with the general form d[S]/dV that can be integrated numerically to calculate the equilibrium concentrations of free and bound species S at every injection step and, subsequently, to evaluate the volume-normalized heat signal (δQ(V) = δq/dV) of direct and reverse calorimetry titrations. Additionally, we identify factors that influence the shape of the titration curve and can be used to optimize the initial concentrations of titrant and analyte. We demonstrate the flexibility of our updated DBM by applying these differentials and a global regression analysis to direct and reverse calorimetric titrations of gadolinium ions with multidentate ligands of increasing denticity, namely, diglycolic acid (DGA), citric acid (CIT), and nitrilotriacetic acid (NTA), and use statistical tests to validate the stoichiometries for the metal-ligand pairs studied.

  1. What does calorimetry and thermodynamics of living cells tell us?

    Science.gov (United States)

    Maskow, Thomas; Paufler, Sven

    2015-04-01

    This article presents and compares several thermodynamic methods for the quantitative interpretation of data from calorimetric measurements. Heat generation and absorption are universal features of microbial growth and product formation as well as of cell cultures from animals, plants and insects. The heat production rate reflects metabolic changes in real time and is measurable on-line. The detection limit of commercially available calorimetric instruments can be low enough to measure the heat of 100,000 aerobically growing bacteria or of 100 myocardial cells. Heat can be monitored in reaction vessels ranging from a few nanoliters up to many cubic meters. Most important the heat flux measurement does not interfere with the biological process under investigation. The practical advantages of calorimetry include the waiver of labeling and reactants. It is further possible to assemble the thermal transducer in a protected way that reduces aging and thereby signal drifts. Calorimetry works with optically opaque solutions. All of these advantages make calorimetry an interesting method for many applications in medicine, environmental sciences, ecology, biochemistry and biotechnology, just to mention a few. However, in many cases the heat signal is merely used to monitor biological processes but only rarely to quantitatively interpret the data. Therefore, a significant proportion of the information potential of calorimetry remains unutilized. To fill this information gap and to motivate the reader using the full information potential of calorimetry, various methods for quantitative data interpretations are presented, evaluated and compared with each other. Possible errors of interpretation and limitations of quantitative data analysis are also discussed. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Pedal indirect lymphangiography

    International Nuclear Information System (INIS)

    Lee, Kil Woo; Hong, Myung Sun; Kim, In Jae

    1994-01-01

    Recently, indirect lymphangiography has been developed as a relatively good and noninvasive imaging modality of the lymphatic system at extremities. But the disadvantage of the indirect lymphangiography is a low contrast ratio between the surrounding tissues and the contrast media in lymphatic vessels, because dimeric nonionic contrast media is water soluble and diluted in the proximal leg lymphatic vessels. We could have relatively better image than previously published images for the leg lymphatic system, when we injected contrast media with adequate high pressure in intradermal space of the interdigital areas at the foot dorsum. So, we would like to report the results. We could study all 9 lymphedemas(primary: 6, secondary: 3) from April 1990 to May 1993 on outpatient base. They were diagnosed as lymphedema clinically and radiologically. Ten ml of dimeric nonionic aget, iotrolan(Isovist 300) was injected into intradermal space with five 30-gauge needles. The injection speed was more than 0.2 ml/min. We have done one side pedal lymphangiogram in 30 minutes. The evaluation of the anterior superficial lymphatics was according to the criteria of the Weissleder. The results were as follows: 1. All lymphatic vessels from foot to inguinal area could be visualized. 2. Two or three inferior inguinal lymph nodes could be visualized about 42%. 3. The most common abnormal finding of the lymphedma was the neovascularization of the lymphatics on indirect pedal lymphangiogram. If we use adequate technique relatively high pressure injection, correct intradermal needle insertion, adequate soft tissue exposure technique indirect lymphangiography is considered to be a safe and noninvasive imaging modality for the evaluation of the lymphedema of lower extremity lymphatics including inferior inguinal lymph nodes

  3. Glass transition of anhydrous starch by fast scanning calorimetry.

    Science.gov (United States)

    Monnier, Xavier; Maigret, Jean-Eudes; Lourdin, Denis; Saiter, Allisson

    2017-10-01

    By means of fast scanning calorimetry, the glass transition of anhydrous amorphous starch has been measured. With a scanning rate of 2000Ks -1 , thermal degradation of starch prior to the glass transition has been inhibited. To certify the glass transition measurement, structural relaxation of the glassy state has been investigated through physical aging as well as the concept of limiting fictive temperature. In both cases, characteristic enthalpy recovery peaks related to the structural relaxation of the glass have been observed. Thermal lag corrections based on the comparison of glass transition temperatures measured by means of differential and fast scanning calorimetry have been proposed. The complementary investigations give an anhydrous amorphous starch glass transition temperature of 312±7°C. This estimation correlates with previous extrapolation performed on hydrated starches. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Scintillating glasses for total absorption dual readout calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Bonvicini, V. [INFN, Trieste; Driutti, A. [Udine U.; Cauz, D. [Udine U.; Pauletta, G. [Udine U.; Rubinov, P. [Fermilab; Santi, L. [Udine U.; Wenzel, H. [Fermilab

    2012-01-01

    Scintillating glasses are a potentially cheaper alternative to crystal - based calorimetry with common problems related to light collection, detection and processing. As such, their use and development are part of more extensive R&D aimed at investigating the potential of total absorption, combined with the readout (DR) technique, for hadron calorimetry. A recent series of measurements, using cosmic and particle beams from the Fermilab test beam facility and scintillating glass with the characteristics required for application of the DR technique, serve to illustrate the problems addressed and the progress achieved by this R&D. Alternative solutions for light collection (conventional and silicon photomultipliers) and signal processing are compared, the separate contributions of scintillation and Cherenkov processes to the signal are evaluated and results are compared to simulation.

  5. Inherent limitations of fixed time servo-controlled radiometric calorimetry

    International Nuclear Information System (INIS)

    Wetzel, J.R.; Duff, M.F.; Lemming, J.F.

    1987-01-01

    There has been some interest in low precision, short run time calorimetry measurements. This type of calorimetry measurement has been proposed for use when high precision measurements are not required, for example, to screen scrap containers to determine if there is enough material to be measured more accurately of for confirmatory measurements that only require low precision results. The equipment needed to make these measurements is a servo-controlled calorimeter with a sample preequilibration bath. The preequilibration bath temperature is set to the internal temperature of the calorimeter running at a fixed servo-controlled wattage level. The sample power value is determined at a fixed time form the sample loading into the calorimeter. There are some limitations and areas of uncertainties in the use of data obtained by this method. Data collected under controlled conditions demonstrate the limitations. Sample packaging, preequilibration time, and item wattage were chosen as the variables most likely to be encountered in a plant environment

  6. Electron beam water calorimetry measurements to obtain beam quality conversion factors.

    Science.gov (United States)

    Muir, Bryan R; Cojocaru, Claudiu D; McEwen, Malcolm R; Ross, Carl K

    2017-10-01

    To provide results of water calorimetry and ion chamber measurements in high-energy electron beams carried out at the National Research Council Canada (NRC). There are three main aspects to this work: (a) investigation of the behavior of ionization chambers in electron beams of different energies with focus on long-term stability, (b) water calorimetry measurements to determine absorbed dose to water in high-energy beams for direct calibration of ion chambers, and (c) using measurements of chamber response relative to reference ion chambers, determination of beam quality conversion factors, k Q , for several ion chamber types. Measurements are made in electron beams with energies between 8 MeV and 22 MeV from the NRC Elekta Precise clinical linear accelerator. Ion chamber measurements are made as a function of depth for cylindrical and plane-parallel ion chambers over a period of five years to investigate the stability of ion chamber response and for indirect calibration. Water calorimetry measurements are made in 18 MeV and 22 MeV beams. An insulated enclosure with fine temperature control is used to maintain a constant temperature (drifts less than 0.1 mK/min) of the calorimeter phantom at 4°C to minimize effects from convection. Two vessels of different designs are used with calibrated thermistor probes to measure radiation induced temperature rise. The vessels are filled with high-purity water and saturated with H 2 or N 2 gas to minimize the effect of radiochemical reactions on the measured temperature rise. A set of secondary standard ion chambers are calibrated directly against the calorimeter. Finally, several other ion chambers are calibrated in the NRC 60 Co reference field and then cross-calibrated against the secondary standard chambers in electron beams to realize k Q factors. The long-term stability of the cylindrical ion chambers in electron beams is better (always <0.15%) than plane-parallel chambers (0.2% to 0.4%). Calorimetry measurements

  7. CONTRIBUTION OF INDIRECT TAXES

    Directory of Open Access Journals (Sweden)

    CHIRCULESCU MARIA FELICIA

    2015-08-01

    Full Text Available The work is based on the fact that at any time and in any society, taxation is regarded as undesirable for all taxpayers. The existence and it's manifestation is justified, because the operation of any company involves costs that must be covered by sufficient resources. Since ancient times, each state has adopted its own tax system, more or less perfected, as the state has experienced a greater or lesser economic and military power At the base of this work stays the fact that tax systems are a key factor influencing the overall efficiency of the economy. They determine the size tendency to save, invest and work, influencing the increase in production and employment, which is essential sights integral economic strategy, making tax reform an important component of economic reform. This paper aims to analyze the indirect taxes and their contribution to the public revenues in Romania, the purpose paper contains an analysis based on statistical series as indirect taxation is where tax harmonization was possible. Through analyzes, the paper aims to provide answers to the problem of the contradiction between the growing need for budgetary revenues, which entails a continuous amplification and diversification of taxation, on the one hand, and the need to stimulate economic development, on the other hand. The harmonization of indirect taxation had been achieved since this touches the free movement of goods and the freedom to supply services, not being able to say the same thing about direct taxation, which is why the European Community Treaty does not specify expressly the alignment of direct taxation, considering that direct taxation is a matter of Internal Policies that, for a country free option.

  8. Physicochemical characterization of pitches by differential scanning calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Lahaye, J.; Ehrburger, P.; Saint-Romain, J.L.; Couderc, P.

    1987-11-01

    The glass transition characterization of pitches has been studied by differential scanning calorimetry (d.s.c.). Experimental results and theoretical considerations indicate that: (1) the average molecular mass of pitches can be characterized by the apparent activation energy of the relaxation phenomenon of pitch molecules; (2) the molecular polydispersity is correlated with the width of the glass transition. Characterization of pitch by d.s.c. is well adapted to follow pitch transformation during heat treatment. 6 refs., 6 figs., 4 tabs.

  9. The upgraded CDF front end electronics for calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Drake, G.; Frei, D.; Hahn, S.R.; Nelson, C.A.; Segler, S.L.; Stuermer, W.

    1991-11-01

    The front end electronics used in the calorimetry of the CDF detector has been upgraded to meet system requirements for higher expected luminosity. A fast digitizer utilizing a 2 {mu}Sec, 16 bit ADC has been designed and built. Improvements to the front end trigger circuitry have been implemented, including the production of 900 new front end modules. Operational experience with the previous system is presented, with discussion of the problems and performance goals.

  10. The upgraded CDF front end electronics for calorimetry

    International Nuclear Information System (INIS)

    Drake, G.; Frei, D.; Hahn, S.R.; Nelson, C.A.; Segler, S.L.; Stuermer, W.

    1991-11-01

    The front end electronics used in the calorimetry of the CDF detector has been upgraded to meet system requirements for higher expected luminosity. A fast digitizer utilizing a 2 μSec, 16 bit ADC has been designed and built. Improvements to the front end trigger circuitry have been implemented, including the production of 900 new front end modules. Operational experience with the previous system is presented, with discussion of the problems and performance goals

  11. The Philosophy and Feasibility of Dual Readout Calorimetry

    International Nuclear Information System (INIS)

    Hauptman, John

    2006-01-01

    I will discuss the general physical ideas behind dual-readout calorimetry, their implementation in DREAM (Dual REAdout Module) with exact separation of scintillation and Cerenkov light, implementation with mixed light in DREAM fibers, anticipated implementation in PbWO4 crystals with applications to the 4th Concept detector and to CMS, use in high energy gamma-ray and cosmic ray astrophysics with Cerenkov and N2 fluorescent light, and implementation in the 4th Concept detector for muon identification

  12. Application of kinetic inductance thermometers to x-ray calorimetry

    International Nuclear Information System (INIS)

    Wai, Y.C.; Labov, S.E.; Silver, E.H.

    1990-01-01

    A kinetic inductance thermometer is applied to x-ray calorimetry, and its operation over a wide range of frequencies and geometries is discussed. Three amplifier configurations are described, one using a superconducting quantum interference device (SQUID) amplifier, another incorporating an FET amplifier in an amplitude modulated system, and the third, using a tunnel diode frequency modulated oscillator circuit. The predicted performance of each configuration is presented. 13 refs., 6 figs., 1 tab

  13. Whole-body fat oxidation determined by graded exercise and indirect calorimetry: a role for muscle oxidative capacity?

    DEFF Research Database (Denmark)

    Nordby, P; Saltin, B; Helge, J W

    2006-01-01

    During whole-body exercise, peak fat oxidation occurs at a moderate intensity. This study investigated whole-body peak fat oxidation in untrained and trained subjects, and the presence of a relation between skeletal muscle oxidative enzyme activity and whole-body peak fat oxidation. Healthy male...... subjects were recruited and categorized into an untrained (N=8, VO(2max) 3.5+/-0.1 L/min) and a trained (N=8, VO(2max) 4.6+/-0.2 L/min) group. Subjects performed a graded exercise test commencing at 60 W for 8 min followed by 35 W increments every 3 min. On a separate day, muscle biopsies were obtained...... oxidation was determined. The body composition was determined by DEXA. Whole-body peak fat oxidation (250+/-25 and 462+/-33 mg/min) was higher (Ptrained compared with untrained subjects, respectively. Muscle...

  14. Indirect carotid cavernous fistula mimicking ocular myasthenia.

    Science.gov (United States)

    Leishangthem, Lakshmi; Satti, Sudhakar Reddy

    2017-10-19

    71-year-old woman with progressive left-sided, monocular diplopia and ptosis. Her symptoms mimicked ocular myasthenia, but she had an indirect carotid cavernous fistula (CCF). She was diagnosed with monocular myasthenia gravis (negative acetylcholinesterase antibody) after a positive ice test and started on Mestinon and underwent a thymectomy complicated by a brachial plexus injury. Months later, she developed left-sided proptosis and ocular bruit. She was urgently referred to neuro-interventional surgery and was diagnosed with an indirect high-flow left CCF, which was treated with Onyx liquid and platinum coil embolisation. Mestinon was discontinued. Her ophthalmic symptoms resolved. However, she was left with a residual left arm and hand hemiparesis and dysmetria secondary to a brachial plexus injury. Indirect CCF usually can present with subtle and progressive symptoms leading to delayed diagnosis or misdiagnosis. It is important for ophthalmologists to consider this differential in a patient with progressive ocular symptoms. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  15. Calorimetry exchange program annual data report for 1992

    International Nuclear Information System (INIS)

    Barnett, T.M.

    1992-01-01

    The goals of the Calorimetry Sample Exchange Program are: discuss measurement differences; review and improve analytical measurements and methods; discuss new measurement capabilities; provide data to DOE on measurement capabilities to evaluate shipper-receiver differences; provide characterized or standard materials as necessary for exchange participants; and provide a measurement control program for plutonium analysis. A sample of PuO 2 powder is available at each participating site for NDA measurement, including either or both calorimetry and high-resolution gamma-ray spectroscopy, the elements which are typically combined to provide a calorimetric assay of plutonium. The facilities measure the sample as frequently and to the level of precision which they desire, and then submit the data to the Exchange for analysis. The data report includes summary tables for each measurement and charts showing the performance of each laboratory. Comparisons are made to the accepted values for the exchange sample and to data previously reported by that laboratory. This information is presented, in the form of quarterly and annual reports, intended for use by Exchange participants in measurement control programs, or to indicate when bias corrections may be appropriate. No attempt, however, has been made to standardize methods or frequency of data collection, calibration, or operating procedures. Direct comparisons between laboratories may, therefore, be misleading since data have not been collected to the same precision or for the same time periods. A meeting of the participants of the Calorimetry Exchange is held annually at EG ampersand G Mound Applied Technologies. The purposes of this meeting are to discuss measurement differences, problems, and new measurement capabilities, and to determine the additional activities needed to fulfill the goals of the Exchange. This document provides data for 1992

  16. Fast differential scanning calorimetry of liquid samples with chips

    DEFF Research Database (Denmark)

    Splinter, R.; van Herwaarden, A. W.; van Wetten, I. A.

    2015-01-01

    Based on a modified version of standard chips for fast differential scanning calorimetry, DSC of liquid samples has been performed at temperature scan rates of up to 1000 °C/s. This paper describes experimental results with the protein lysozyme, bovine serum, and olive oil. The heating and cooling....... The bovine serum measurements show two main peaks, in good agreement with standard DSC measurements. Olive oil has been measured, with good agreement for the cooling curve and qualitative agreement for the heater curve, compared to DSC measurements....

  17. Neutral-beam aiming and calorimetry for MFTF-B

    International Nuclear Information System (INIS)

    Goldner, A.I.; Margolies, D.

    1981-01-01

    The vessel for the Tandem Mirror Fusion Test Facility (MFTF-B) will have up to eleven 0.5-s-duration neutral-beam injectors for the initial heating of the MFTF-B plasma. Knowing the exact alignment of the beams and their total power is critical to the performance of the experiment. Using prototype aiming and calorimetry systems on the High Voltage Test Stand (HVTS) at Lawrence Livermore National Laboratory (LLNL), we hope to prove our ability to obtain an aiming accuracy of +-1 cm at the plasma and a calorimetric accuracy of +-5% of the actual total beam energy

  18. A custom floating point format ADC for LHC calorimetry

    International Nuclear Information System (INIS)

    Hermel, V.; Lecoq, J.; Bohner, G.

    1996-01-01

    Due to their large dynamic range (in excess of 16 bits) signals from LHC calorimetry poses severe problems to the shaping and digitizing circuits. We are investigating a solution for an ADC based on a custom floating point format. Since the calorimeter precision is limited, the full dynamic range can be split into 8 positive sub-ranges and 5 negative ones, each with an 8 bits dynamic. The reduced number of bits (8 for the mantissa, 4 for the exponent and 1 for the sign) translates itself into a reduction of the power consumption both of the ADC and of the following digital filtering stages. (authors)

  19. The Pandora Software Development Kit for Particle Flow Calorimetry

    International Nuclear Information System (INIS)

    Marshall, J S; Thomson, M A

    2012-01-01

    Pandora is a robust and efficient framework for developing and running pattern-recognition algorithms. It was designed to perform particle flow calorimetry, which requires many complex pattern-recognition techniques to reconstruct the paths of individual particles through fine granularity detectors. The Pandora C++ software development kit (SDK) consists of a single library and a number of carefully designed application programming interfaces (APIs). A client application can use the Pandora APIs to pass details of tracks and hits/cells to the Pandora framework, which then creates and manages named lists of self-describing objects. These objects can be accessed by Pandora algorithms, which perform the pattern-recognition reconstruction. Development with the Pandora SDK promotes the creation of small, re-usable algorithms containing just the kernel of a specific operation. The algorithms are configured via XML and can be nested to perform complex reconstruction tasks. As the algorithms only access the Pandora objects in a controlled manner, via the APIs, the framework can perform most book-keeping and memory-management operations. The Pandora SDK has been fully exploited in the implementation of PandoraPFA, which uses over 60 algorithms to provide the state of the art in particle flow calorimetry for ILC and CLIC.

  20. Evaluation of aluminosilicate glass sintering during differential scanning calorimetry

    International Nuclear Information System (INIS)

    Souza, Juliana Pereira de

    2015-01-01

    In this work a difference in the baseline in differential scanning calorimetry analyses, observed in a work where aluminosilicate glasses microspheres containing Ho were studied for application in selective internal radiotherapy as hepatocellular carcinoma treatment, was studied. The glasses with nominal composition 53,7 SiO 2 .10,5 Al 2 O 3 . 35,8 MgO in %mol were produced from traditional melting. The first obtained were milled and sieved in the range of 45 a 63 μm. The material was used to produce glass microspheres by the gravitational fall method. The glass powder and the microspheres were characterized by X ray fluorescence spectrometry, laser diffraction, X ray diffraction, differential scanning calorimetry, differential thermal analysis, thermogravimetry, mass spectrometry, and scanning electron microscopy. After the thermal analyses, pellets were formed in the crucibles and were analyzed by scanning electron microscopy, X ray diffraction, and He pycnometry. The difference in the baseline was associated to the viscous flow sintering process and happens because of the decrease in the detected heat flow due to the sample shrinkage. Other events as concurrent crystallization with the sintering process were also studied. (author)

  1. Tritium inventory measurements by 'in-bed' gas flowing calorimetry

    International Nuclear Information System (INIS)

    Hayashi, T.; Suzuki, T.; Yamada, M.; Okuno, K.

    1996-01-01

    In order to establish the 'in-bed' tritium accounting technology for the ITER scale tritium storage system, a gas flowing calorimetry has been studied using a scaled ZrCo bed (25 g tritium capacity). The basic calorimetric characteristics, steady state temperature raise of He gas stream flowing through a secondary coil line fixed in the ZrCo tritide, was measured and correlated with the stored tritium inventory. The results shows that about 4 degrees raise of He stream temperature can be detected for each gram of tritium storage. The sensitivity of this calorimetry is about 0.05 g of tritium, calculated by 0.2 degrees of temperature sensor error. The accuracy is better than 0.25 g of tritium on 25 g storage, evaluated by 2 times of standard deviation from the repeat measurements. This accuracy of < 1% on full storage capacity is satisfied the target accountability to measure ± 1 gram of tritium on 100 g storage for ITER. 13 refs., 7 figs

  2. Single-experiment displacement assay for quantifying high-affinity binding by isothermal titration calorimetry.

    Science.gov (United States)

    Krainer, Georg; Keller, Sandro

    2015-04-01

    Isothermal titration calorimetry (ITC) is the gold standard for dissecting the thermodynamics of a biomolecular binding process within a single experiment. However, reliable determination of the dissociation constant (KD) from a single titration is typically limited to the range 100 μM>KD>1 nM. Interactions characterized by a lower KD can be assessed indirectly by so-called competition or displacement assays, provided that a suitable competitive ligand is available whose KD falls within the directly accessible window. However, this protocol is limited by the fact that it necessitates at least two titrations to characterize one high-affinity inhibitor, resulting in considerable consumption of both sample material and time. Here, we introduce a fast and efficient ITC displacement assay that allows for the simultaneous characterization of both a high-affinity ligand and a moderate-affinity ligand competing for the same binding site on a receptor within a single experiment. The protocol is based on a titration of the high-affinity ligand into a solution containing the moderate-affinity ligand bound to the receptor present in excess. The resulting biphasic binding isotherm enables accurate and precise determination of KD values and binding enthalpies (ΔH) of both ligands. We discuss the theoretical background underlying the approach, demonstrate its practical application to metal ion chelation, explore its potential and limitations with the aid of simulations and statistical analyses, and elaborate on potential applications to protein-inhibitor interactions. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Serum Zn levels in dysphagic patients who underwent endoscopic gastrostomy for long term enteral nutrition

    OpenAIRE

    Adriana Santos, Carla; Fonseca, Jorge; Brito, José; Fernandes, Tânia; Gonçalves, Luísa; Sousa Guerreiro, António

    2014-01-01

    Background and aims: Dysphagic patients who underwent endoscopic gastrostomy (PEG) usually present protein-energy malnutrition, but little is known about micronutrient malnutrition. The aim of the present study was the evaluation of serum zinc in patients who underwent endoscopic gastrostomy and its relationship with serum proteins, whole blood zinc, and the nature of underlying disorder. Methods: From patients that underwent gastrostomy a blood sample was obtained minutes before the procedur...

  4. Advanced ion beam calorimetry for the test facility ELISE

    International Nuclear Information System (INIS)

    Nocentini, R.; Fantz, U.; Franzen, P.; Fröschle, M.; Heinemann, B.; Riedl, R.; Ruf, B.; Wünderlich, D.; Bonomo, F.; Pimazzoni, A.; Pasqualotto, R.

    2015-01-01

    The negative ion source test facility ELISE (Extraction from a Large Ion Source Experiment) is in operation since beginning of 2013 at the Max-Planck-Institut für Plasmaphysik (IPP) in Garching bei München. The large radio frequency driven ion source of ELISE is about 1×1 m 2 in size (1/2 the ITER source) and can produce a plasma for up to 1 h. Negative ions can be extracted and accelerated by an ITER-like extraction system made of 3 grids with an area of 0.1 m 2 , for 10 s every 3 minutes. A total accelerating voltage of up to 60 kV is available, i.e. a maximum ion beam power of about 1.2 MW can be produced. ELISE is equipped with several beam diagnostic tools for the evaluation of the beam characteristics. In order to evaluate the beam properties with a high level of detail, a sophisticated diagnostic calorimeter has been installed in the test facility at the end of 2013, starting operation in January 2014. The diagnostic calorimeter is split into 4 copper plates with separate water calorimetry for each of the plates. Each calorimeter plate is made of 15×15 copper blocks, which act as many separate inertial calorimeters and are attached to a copper plate with an embedded cooling circuit. The block geometry and the connection with the cooling plate are optimized to accurately measure the time-averaged power of the 10 s ion beam. The surface of the blocks is covered with a black coating that allows infrared (IR) thermography which provides a 2D profile of the beam power density. In order to calibrate the IR thermography, 48 thermocouples are installed in as many blocks, arranged in two vertical and two horizontal rows. The paper describes the beam calorimetry in ELISE, including the methods used for the IR thermography, the water calorimetry and the analytical methods for beam profile evaluation. It is shown how the maximum beam inhomogeneity amounts to 13% in average. The beam divergence derived by IR thermography ranges between 1° and 4° and

  5. Detectors for Linear Colliders: Calorimetry at a Future Electron-Positron Collider (3/4)

    CERN Multimedia

    CERN. Geneva

    2010-01-01

    Calorimetry will play a central role in determining the physics reach at a future e+e- collider. The requirements for calorimetry place the emphasis on achieving an excellent jet energy resolution. The currently favoured option for calorimetry at a future e+e- collider is the concept of high granularity particle flow calorimetry. Here granularity and a high pattern recognition capability is more important than the single particle calorimetric response. In this lecture I will describe the recent progress in understanding the reach of high granularity particle flow calorimetry and the related R&D efforts which concentrate on test beam demonstrations of the technological options for highly granular calorimeters. I will also discuss alternatives to particle flow, for example the technique of dual readout calorimetry.

  6. Hydroxylamine nitrate self-catalytic kinetics study with adiabatic calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Liu Lijun [Mary Kay O' Connor Process Safety Center, Artie McFerrin Department of Chemical Engineering, Texas A and M University System, College Station, TX 77843-3122 (United States); Wei Chunyang [BASF Corporation, Wyandotte, MI 48192 (United States); Guo Yuyan; Rogers, William J. [Mary Kay O' Connor Process Safety Center, Artie McFerrin Department of Chemical Engineering, Texas A and M University System, College Station, TX 77843-3122 (United States); Sam Mannan, M. [Mary Kay O' Connor Process Safety Center, Artie McFerrin Department of Chemical Engineering, Texas A and M University System, College Station, TX 77843-3122 (United States)], E-mail: mannan@tamu.edu

    2009-03-15

    Hydroxylamine nitrate (HAN) is an important member of the hydroxylamine compound family with applications that include equipment decontamination in the nuclear industry and aqueous or solid propellants. Due to its instability and autocatalytic behavior, HAN has been involved in several incidents at the Hanford and Savannah River Site (SRS) [Technical Report on Hydroxylamine Nitrate, US Department of Energy, 1998]. Much research has been conducted on HAN in different areas, such as combustion mechanism, decomposition mechanism, and runaway behavior. However, the autocatalytic decomposition behavior of HAN at runaway stage has not been fully addressed due to its highly exothermic and rapid decomposition behavior. This work is focused on extracting HAN autocatalytic kinetics and analyzing HAN critical behavior from adiabatic calorimetry measurements. A lumped autocatalytic kinetic model for HAN and associated model parameters are determined. Also the storage and handling critical conditions of diluted HAN solution without metal presence are quantified.

  7. Review of MEMS differential scanning calorimetry for biomolecular study

    Science.gov (United States)

    Yu, Shifeng; Wang, Shuyu; Lu, Ming; Zuo, Lei

    2017-12-01

    Differential scanning calorimetry (DSC) is one of the few techniques that allow direct determination of enthalpy values for binding reactions and conformational transitions in biomolecules. It provides the thermodynamics information of the biomolecules which consists of Gibbs free energy, enthalpy and entropy in a straightforward manner that enables deep understanding of the structure function relationship in biomolecules such as the folding/unfolding of protein and DNA, and ligand bindings. This review provides an up to date overview of the applications of DSC in biomolecular study such as the bovine serum albumin denaturation study, the relationship between the melting point of lysozyme and the scanning rate. We also introduce the recent advances of the development of micro-electro-mechanic-system (MEMS) based DSCs.

  8. On the Interpretation of Low Temperature Calorimetry Data

    DEFF Research Database (Denmark)

    Kjeldsen, Ane Mette; Geiker, Mette Rica

    2008-01-01

    The effect of selected factors and phenomena on Low Temperature Calorimetry (LTC) results has been investigated, in order to determine the possibilities and limitations of using LTC for characterisation of the porosity of cement-based materials. LTC was carried out on a model material with mono......-sized pores of approximately 14 nm saturated with either distilled water or a sodium chloride solution, as well as on water, the salt solution, and an artificial pore solution, alone. It was found that supercooling is unavoidable during the liquid-solid phase transition, and that even at low temperature...... to limit transport of liquid, whereas heating should be undertaken at a low rate to limit the effect of non-equilibrium....

  9. Probing Free-Energy Surfaces with Differential Scanning Calorimetry

    Science.gov (United States)

    Sanchez-Ruiz, Jose M.

    2011-05-01

    Many aspects of protein folding can be understood in terms of projections of the highly dimensional energy landscape onto a few (or even only one) particularly relevant coordinates. These free-energy surfaces can be probed conveniently from experimental differential scanning calorimetry (DSC) thermograms, as DSC provides a direct relation with the protein partition function. Free-energy surfaces thus obtained are consistent with two fundamental scenarios predicted by the energy-landscape perspective: (a) well-defined macrostates separated by significant free-energy barriers, in some cases, and, in many other cases, (b) marginal or even vanishingly small barriers, which furthermore show a good correlation with kinetics for fast- and ultrafast-folding proteins. Overall, the potential of DSC to assess free-energy surfaces for a wide variety of proteins makes it possible to address fundamental issues, such as the molecular basis of the barrier modulations produced by natural selection in response to functional requirements or to ensure kinetic stability.

  10. Hydroxylamine nitrate self-catalytic kinetics study with adiabatic calorimetry

    International Nuclear Information System (INIS)

    Liu Lijun; Wei Chunyang; Guo Yuyan; Rogers, William J.; Sam Mannan, M.

    2009-01-01

    Hydroxylamine nitrate (HAN) is an important member of the hydroxylamine compound family with applications that include equipment decontamination in the nuclear industry and aqueous or solid propellants. Due to its instability and autocatalytic behavior, HAN has been involved in several incidents at the Hanford and Savannah River Site (SRS) [Technical Report on Hydroxylamine Nitrate, US Department of Energy, 1998]. Much research has been conducted on HAN in different areas, such as combustion mechanism, decomposition mechanism, and runaway behavior. However, the autocatalytic decomposition behavior of HAN at runaway stage has not been fully addressed due to its highly exothermic and rapid decomposition behavior. This work is focused on extracting HAN autocatalytic kinetics and analyzing HAN critical behavior from adiabatic calorimetry measurements. A lumped autocatalytic kinetic model for HAN and associated model parameters are determined. Also the storage and handling critical conditions of diluted HAN solution without metal presence are quantified

  11. Novel investigation of enzymatic biodiesel reaction by isothermal calorimetry

    DEFF Research Database (Denmark)

    Søtoft, Lene Fjerbaek; Westh, Peter; Christensen, Knud V.

    2010-01-01

    Isothermal calorimetry (ITC) was used to investigate solvent-free enzymatic biodiesel production. The transesterification of rapeseed oil with methanol and ethanol was catalyzed by immobilized lipase Novozym 435 at 40 °C. The aim of the study was to determine reaction enthalpy for the enzymatic...... transesterification and to elucidate the mass transfer and energetic processes taking place. Based on the measured enthalpy and composition change in the system, the heat of reaction at 40 °C for the two systems was determined as −9.8 ± 0.9 kJ/mole biodiesel formed from rapeseed oil and methanol, and −9.3 ± 0.7 k...

  12. Prospects for and tests of hadron calorimetry with silicon

    International Nuclear Information System (INIS)

    Brau, J.E.; Gabriel, T.A.; Rancoita, P.G.

    1989-03-01

    Hadron calorimetry with silicon may provide crucial capabilities in experiments at the high luminosity, high energy colliders of the future, particularly due to silicon's fast intrinsic speed and absolute calibration. The important underlying processes of our understanding of hadron calorimeters are reviewed to set the framework for the presentation of recent calculations of the expected performance of silicon detector based hadron calorimeters. Such devices employing uranium are expected to achieve the compensation condition (that is, the ratio of the most probable electron signal to hadron signal (e/h) is ∼1.0) based on the understanding that has been derived from the uranium-liquid argon and uranium-plastic scintillator systems. In fact, even lead-silicon calorimeters are found to achieve the attractive value for the e/h ratio of 1.16 at 10 GeV. An experimental test of these predictions is underway at CERN by the SICAPO Collaboration. 64 refs., 19 figs

  13. The importance of calorimetry for highly-boosted jet substructure

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, Evan [Brown U.; Freytsis, Marat [Oregon U.; Hinzmann, Andreas [Hamburg U.; Narain, Meenakshi [Brown U.; Thaler, Jesse [MIT, Cambridge, CTP; Tran, Nhan [Fermilab; Vernieri, Caterina [Fermilab

    2017-09-25

    Jet substructure techniques are playing an essential role in exploring the TeV scale at the Large Hadron Collider (LHC), since they facilitate the efficient reconstruction and identification of highly-boosted objects. Both for the LHC and for future colliders, there is a growing interest in using jet substructure methods based only on charged-particle information. The reason is that silicon-based tracking detectors offer excellent granularity and precise vertexing, which can improve the angular resolution on highly-collimated jets and mitigate the impact of pileup. In this paper, we assess how much jet substructure performance degrades by using track-only information, and we demonstrate physics contexts in which calorimetry is most beneficial. Specifically, we consider five different hadronic final states - W bosons, Z bosons, top quarks, light quarks, gluons - and test the pairwise discrimination power with a multi-variate combination of substructure observables. In the idealized case of perfect reconstruction, we quantify the loss in discrimination performance when using just charged particles compared to using all detected particles. We also consider the intermediate case of using charged particles plus photons, which provides valuable information about neutral pions. In the more realistic case of a segmented calorimeter, we assess the potential performance gains from improving calorimeter granularity and resolution, comparing a CMS-like detector to more ambitious future detector concepts. Broadly speaking, we find large performance gains from neutral-particle information and from improved calorimetry in cases where jet mass resolution drives the discrimination power, whereas the gains are more modest if an absolute mass scale calibration is not required.

  14. Local Measurement of Fuel Energy Deposition and Heat Transfer Environment During Fuel Lifetime Using Controlled Calorimetry

    International Nuclear Information System (INIS)

    Don W. Miller; Andrew Kauffmann; Eric Kreidler; Dongxu Li; Hanying Liu; Daniel Mills; Thomas D. Radcliff; Joseph Talnagi

    2001-01-01

    A comprehensive description of the accomplishments of the DOE grant titled, ''Local Measurement of Fuel Energy Deposition and Heat Transfer Environment During Fuel Lifetime using Controlled Calorimetry''

  15. Supersymmetric dark matter: Indirect detection

    International Nuclear Information System (INIS)

    Bergstroem, L.

    2000-01-01

    Dark matter detection experiments are improving to the point where they can detect or restrict the primary particle physics candidates for non baryonic dark matter. The methods for detection are usually categorized as direct, i.e., searching for signals caused by passage of dark matter particles in terrestrial detectors, or indirect. Indirect detection methods include searching for antimatter and gamma rays, in particular gamma ray lines, in cosmic rays and high-energy neutrinos from the centre of the Earth or Sun caused by accretion and annihilation of dark matter particles. A review is given of recent progress in indirect detection, both on the theoretical and experimental side

  16. The Complexity of Indirect Translation

    DEFF Research Database (Denmark)

    Wenjie, L. I.

    2017-01-01

    its complex nature, and thus determined that many facets of ITr remain to be studied. The present article will try to encompass the complexity of ITr by looking into the reasons for translating indirectly, the challenge of finding out mediating texts (MTs), indirectness in both translation...... of which have been translated and interpreted indirectly through major languages like English, will be employed as examples. Hopefully, this study will offer more insights into the nature of translation as a social activity and raise further interests in studying translation as a complex phenomenon....

  17. A simplified indirect bonding technique

    Directory of Open Access Journals (Sweden)

    Radha Katiyar

    2014-01-01

    Full Text Available With the advent of lingual orthodontics, indirect bonding technique has become an integral part of practice. It involves placement of brackets initially on the models and then their transfer to teeth with the help of transfer trays. Problems encountered with current indirect bonding techniques used are (1 the possibility of adhesive flash remaining around the base of the brackets which requires removal (2 longer time required for the adhesive to gain enough bond strength for secure tray removal. The new simplified indirect bonding technique presented here overcomes both these problems.

  18. The logic of indirect speech

    Science.gov (United States)

    Pinker, Steven; Nowak, Martin A.; Lee, James J.

    2008-01-01

    When people speak, they often insinuate their intent indirectly rather than stating it as a bald proposition. Examples include sexual come-ons, veiled threats, polite requests, and concealed bribes. We propose a three-part theory of indirect speech, based on the idea that human communication involves a mixture of cooperation and conflict. First, indirect requests allow for plausible deniability, in which a cooperative listener can accept the request, but an uncooperative one cannot react adversarially to it. This intuition is supported by a game-theoretic model that predicts the costs and benefits to a speaker of direct and indirect requests. Second, language has two functions: to convey information and to negotiate the type of relationship holding between speaker and hearer (in particular, dominance, communality, or reciprocity). The emotional costs of a mismatch in the assumed relationship type can create a need for plausible deniability and, thereby, select for indirectness even when there are no tangible costs. Third, people perceive language as a digital medium, which allows a sentence to generate common knowledge, to propagate a message with high fidelity, and to serve as a reference point in coordination games. This feature makes an indirect request qualitatively different from a direct one even when the speaker and listener can infer each other's intentions with high confidence. PMID:18199841

  19. Front-End Electronics in calorimetry: from LHC to ILC

    International Nuclear Information System (INIS)

    De La Taille, Ch.

    2009-09-01

    This report summarizes the electronics developments for liquid argon calorimeter read-out at LHC and the development carried out in the framework of the CALICE collaboration for those of the future linear collider (ILC). It also includes chips designed for multi-anode photomultipliers (MaPMT) used in the OPERA experiment or on ATLAS luminometer, which also find applications in medical imaging. Started in the early 90's, the development for ATLAS calorimetry was extremely challenging in terms of readout speed, radiation tolerance and measurement accuracy. The high speed has required a new approach using current-sensitive preamplifiers instead of charge sensitive ones and the redefinition of noise performance in terms of ENI. The preamplifiers developed at Orsay and the monolithic shapers are described in Chapter 1, including considerations of digital filtering, which was a new technique in our field. Chapter 2 is dedicated to the calibration system, designed and built by Orsay, for which the high performance and accuracy necessitated in-depth studies. The 3. chapter closes the studies for ATLAS with a summary of the detector measurements which had to be carried out on the 200 000 channels in order to understand and model the detector and achieve everywhere the accuracy and uniformity at per-cent level. These developments for ATLAS ended in 2004, although parallel work was also carried out for the NA48 and DO calorimeters which are not detailed here. The next generation of collider will require a new generation of calorimeters, much more granular, referred to as 'imaging calorimetry' with embedded read-out electronics. The ASICs developed for this purpose in the framework of the CALICE collaboration are described in Chapter 4. They integrate all the functionalities of amplification, digitization and read-out making them complex 'System-On-Chip' circuits extremely efficient that find many other applications. A family of 3 chips reads out the Si-W electromagnetic

  20. Thermodynamics of biphasic lanthanide extraction by tripodal diglycolamide: a solution calorimetry study

    NARCIS (Netherlands)

    Ansari, S.A.; Mohapatra, P.K.; Verboom, Willem; Rao, L.

    2016-01-01

    Isothermal titration calorimetry was employed for the direct measurement of the enthalpy of extraction (ΔHextr) of Eu(NO3)3 by using a tripodal diglycolamide (T-DGA) ligand dissolved in n-dodecane containing 5% (v/v) 2-decanol. The enthalpy of extraction obtained by titration calorimetry was in good

  1. Quantifying high-affinity binding of hydrophobic ligands by isothermal titration calorimetry.

    Science.gov (United States)

    Krainer, Georg; Broecker, Jana; Vargas, Carolyn; Fanghänel, Jörg; Keller, Sandro

    2012-12-18

    A fast and reliable quantification of the binding thermodynamics of hydrophobic high-affinity ligands employing a new calorimetric competition experiment is described. Although isothermal titration calorimetry is the method of choice for a quantitative characterization of intermolecular interactions in solution, a reliable determination of a dissociation constant (K(D)) is typically limited to the range 100 μM > K(D) > 1 nM. Interactions displaying higher or lower K(D) values can be assessed indirectly, provided that a suitable competing ligand is available whose K(D) falls within the directly accessible affinity window. This established displacement assay, however, requires the high-affinity ligand to be soluble at high concentrations in aqueous buffer and, consequently, poses serious problems in the study of protein binding involving small-molecule ligands dissolved in organic solvents--a familiar case in many drug-discovery projects relying on compound libraries. The calorimetric competition assay introduced here overcomes this limitation, thus allowing for a detailed thermodynamic description of high-affinity receptor-ligand interactions involving poorly water-soluble compounds. Based on a single titration of receptor into a dilute mixture of the two competing ligands, this competition assay provides accurate and precise values for the dissociation constants and binding enthalpies of both high- and moderate-affinity ligands. We discuss the theoretical background underlying the approach, demonstrate its practical application to metal ion chelation and high-affinity protein-inhibitor interactions, and explore its potential and limitations with the aid of simulations and statistical analyses.

  2. An investigation of calibration methods for solution calorimetry.

    Science.gov (United States)

    Yff, Barbara T S; Royall, Paul G; Brown, Marc B; Martin, Gary P

    2004-01-28

    Solution calorimetry has been used in a number of varying applications within pharmaceutical research as a technique for the physical characterisation of pharmaceutical materials, such as quantifying small degrees of amorphous content, identifying polymorphs and investigating interactions between drugs and carbohydrates or proteins and carbohydrates. A calibration test procedure is necessary to validate the instrumentation; a few of the suggested calibration reactions are the enthalpies of solution associated with dissolving Tris in 0.1 M HCl or NaCl, KCl or propan-1-ol in water. In addition, there are a number of different methods available to determine enthalpies of solution from the experimental data provided by the calorimeter, for example, the Regnault-Pfaundler's method, a graphical extrapolation based on the Dickinson method, or a manual integration-based method. Thus, the aim of the study was to investigate how each of these methods influences the values for the enthalpy of solution. Experiments were performed according to the method outlined by Hogan and Buckton [Int. J. Pharm. 207 (2000) 57] using KCl (samples of 50, 100 and 200 mg), Tris and sucrose as calibrants. For all three materials the manual integration method was found to be the most consistent with the KCl in water (sample mass of 200 mg) being the most precise. Thus, this method is recommended for the validation of solution calorimeters.

  3. Applying fast calorimetry on a spent nuclear fuel calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Liljenfeldt, Henrik [Swedish Nuclear Fuel and Waste Management (Sweden); Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Uppsala Univ. (Sweden)

    2015-04-15

    Recently at Los Alamos National Laboratory, sophisticated prediction algorithms have been considered for the use of calorimetry for treaty verification. These algorithms aim to predict the equilibrium temperature based on early data and therefore be able to shorten the measurement time while maintaining good accuracy. The algorithms have been implemented in MATLAB and applied on existing equilibrium measurements from a spent nuclear fuel calorimeter located at the Swedish nuclear fuel interim storage facility. The results show significant improvements in measurement time in the order of 15 to 50 compared to equilibrium measurements, but cannot predict the heat accurately in less time than the currently used temperature increase method can. This Is both due to uncertainties in the calibration of the method as well as identified design features of the calorimeter that limits the usefulness of equilibrium type measurements. The conclusions of these findings are discussed, and suggestions of both improvements of the current calorimeter as well as what to keep in mind in a new design are given.

  4. Isothermal reaction calorimetry as a tool for kinetic analysis

    International Nuclear Information System (INIS)

    Zogg, Andreas; Stoessel, Francis; Fischer, Ulrich; Hungerbuehler, Konrad

    2004-01-01

    Reaction calorimetry has found widespread application for thermal and kinetic analysis of chemical reactions in the context of thermal process safety as well as process development. This paper reviews the most important reaction calorimetric principles (heat-flow, heat-balance, power-compensation, and Peltier principle) and their applications in commercial or scientific devices. The discussion focuses on the different dynamic behavior of the main calorimetric principles during an isothermal reaction measurement. Examples of available reaction calorimeters are further compared considering their detection limit, time constant as well as temperature range. In a second part, different evaluation methods for the isothermally measured calorimetric data are reviewed and discussed. The methods will be compared, focusing especially on the fact that reaction calorimetric data always contains additional informations not directly related to the actual chemical reaction such as heat of mixing, heat of phase-transfer/change processes or simple measurement errors. Depending on the evaluation method applied such disturbances have a significant influence on the calculated reaction enthalpies or rate constants

  5. Thermodynamic properties of soddyite from solubility and calorimetry measurements

    International Nuclear Information System (INIS)

    Gorman-Lewis, Drew; Mazeina, Lena; Fein, Jeremy B.; Szymanowski, Jennifer E.S.; Burns, Peter C.; Navrotsky, Alexandra

    2007-01-01

    The release of uranium from geologic nuclear waste repositories under oxidizing conditions can only be modeled if the thermodynamic properties of the secondary uranyl minerals that form in the repository setting are known. Toward this end, we synthesized soddyite ((UO 2 ) 2 (SiO 4 )(H 2 O) 2 ), and performed solubility measurements from both undersaturation and supersaturation. The solubility measurements rigorously constrain the value of the solubility product of synthetic soddyite, and consequently its standard-state Gibbs free energy of formation. The log solubility product (lg K sp ) with its error (1σ) is (6.43 + 0.20/-0.37), and the standard-state Gibbs free energy of formation is (-3652.2 ± 4.2 (2σ)) kJ mol -1 . High-temperature drop solution calorimetry was conducted, yielding a calculated standard-state enthalpy of formation of soddyite of (-4045.4 ± 4.9 (2σ)) kJ . mol -1 . The standard-state Gibbs free energy and enthalpy of formation yield a calculated standard-state entropy of formation of soddyite of (-1318.7 ± 21.7 (2σ)) J . mol -1 . K -1 . The measurements and associated thermodynamic calculations not only describe the T = 298 K stability and solubility of soddyite, but they also can be used in predictions of repository performance through extrapolation of these properties to repository temperatures

  6. Test of calorimetry for high burn-up plutonium

    International Nuclear Information System (INIS)

    Beets, C.; Carchon, R.; Fettweis, P.

    1984-01-01

    In recent times, the interest of applying calorimetry for safeguards purpose is steadily increasing. Calorimetric measurements have been performed on a set of high burn-up (25000 MWd/t) Pu samples, ranging in mass between 60 g and 2.5 kg Pu, distributed as PuO 2 powder embedded in stainless steel containers. The powers produced by these containers ranged between 0.8 W and 36 W. The calorimeter used was the Mound 150 type, and the isotopics and the Am content have been determined earlier by mass spectroscopy, completed with α and γ counting, and were later verified by the same methods. Watts/gram measurements were made on twelve 60 g samples of the same plutonium lot to demonstrate the Pu elemental and isotopic homogeneity, and hence, its suitability for subsequent NDA experiments. These samples were also measured in a stacked way to fill up the mass and wattage gaps between 60 g (0.8W) and 1 kg (14W). Calorimetric assay values, obtained with both isotopic measurements are discussed

  7. Prospects for and tests of hadron calorimetry with silicon

    Energy Technology Data Exchange (ETDEWEB)

    Brau, James E. [Univ. of Oregon, OR (United States). Dept. of Physics; Gabriel, Tony A. [Oak Ridge National Lab., TN (United States); Rancoita, P. G. [INFN, Milan (Italy)

    1989-03-01

    Hadron calorimetry with silicon may provide crucial capabilities in experiments at the high luminosity, high energy colliders of the future, particularly due to silicon's fast intrinsic speed and absolute calibration. The important underlying processes of our understanding of hadron calorimeters are reviewed to set the framework for the presentation of recent calculations of the expected performance of silicon detector based hadron calorimeters. Such devices employing uranium are expected to achieve the compensation condition (that is, the ratio of the most probable electron signal to hadron signal (e/h) is approx.1.0) based on the understanding that has been derived from the uranium-liquid argon and uranium-plastic scintillator systems. In fact, even lead-silicon calorimeters are found to achieve the attractive value for the e/h ratio of 1.16 at 10 GeV. An experimental test of these predictions is underway at CERN by the SICAPO Collaboration. 64 refs., 19 figs.

  8. Novel Technique for Quantitative Fast Scanning Calorimetry on Electrospun Fibers

    Science.gov (United States)

    Thomas, David; Govinna, Nelaka; Schick, Christoph; Cebe, Peggy

    Fast scanning chip calorimetry allows for the study of polymers which have rapid nucleation and/or crystallization kinetics, or degrade within their melting range. Heating rates used, up to 4000 K/s, allow studies of hetero and homogeneous nucleation at time scales inaccessible with conventional calorimeters, whose rates are typically alcohol (PVA) were chosen in the development of a new methodology to obtain quantitative fast scanning thermal data from electrospun nanofibers using a Flash DSC1. The structure of nanofibers requires special methods to load nanogram-sized samples onto a UFSC1 sensor. Fibers were directly spun onto TEM grids which provide a durable substrate to support bundles of nanofibers and possess excellent thermal conductivity allowing for a strong, repeatable signal and ensure good sample to sensor contact. As spun samples were held isothermally at temperatures ranging from Tg to Tm then heated at 2,000 K/s to assess as-spun crystallinity and cold crystallization behaviors. Above Tm the fibers break up into micro- and nano-droplets. On these samples, melt crystallization experiments were performed to study nucleation and crystallization of polymer confined to nanodroplet morphology. NSF DMR-1608125.

  9. Study of Liquid Argon Dopants for LHC Hadron Calorimetry

    CERN Multimedia

    2002-01-01

    Hadron calorimetry based on the Liquid Argon Ionisation Chamber technique is one of the choice techniques for LHC-experimentation. A systematic study of the effect of selected dopants on Liquid Argon (LAr) will be carried out with the aim to achieve an improvement on: \\item (i)~``Fast Liquid Argon'' search and study of dopants to increase the drift velocity. It has been already shown that CH&sub4. added at a fraction of one percent increases the drift velocity by a factor of two or more. \\item (ii)~``Compensated Liquid Argon'' search and study of dopants to increase the response to densely ionising particles, resulting in improved compensation, such as photosensitive dopants. \\end{enumerate}\\\\ \\\\ Monitoring of the parameters involved in understanding the response of a calorimeter is essential. In case of doped LAr, the charge yield, the non-saturated drift velocity and the electron lifetime in the liquid should be precisely and simultaneously monitored as they all vary with the level of dopant concentrati...

  10. Indirect Reciprocity; A Field Experiment.

    Science.gov (United States)

    van Apeldoorn, Jacobien; Schram, Arthur

    2016-01-01

    Indirect reciprocity involves cooperative acts towards strangers, either in response to their kindness to third parties (downstream) or after receiving kindness from others oneself (upstream). It is considered to be important for the evolution of cooperative behavior amongst humans. Though it has been widely studied theoretically, the empirical evidence of indirect reciprocity has thus far been limited and based solely on behavior in laboratory experiments. We provide evidence from an online environment where members can repeatedly ask and offer services to each other, free of charge. For the purpose of this study we created several new member profiles, which differ only in terms of their serving history. We then sent out a large number of service requests to different members from all over the world. We observe that a service request is more likely to be rewarded for those with a profile history of offering the service (to third parties) in the past. This provides clear evidence of (downstream) indirect reciprocity. We find no support for upstream indirect reciprocity (in this case, rewarding the service request after having previously received the service from third parties), however. Our evidence of downstream indirect reciprocity cannot be attributed to reputational effects concerning one's trustworthiness as a service user.

  11. Indirect Reciprocity under Incomplete Observation

    Science.gov (United States)

    Nakamura, Mitsuhiro; Masuda, Naoki

    2011-01-01

    Indirect reciprocity, in which individuals help others with a good reputation but not those with a bad reputation, is a mechanism for cooperation in social dilemma situations when individuals do not repeatedly interact with the same partners. In a relatively large society where indirect reciprocity is relevant, individuals may not know each other's reputation even indirectly. Previous studies investigated the situations where individuals playing the game have to determine the action possibly without knowing others' reputations. Nevertheless, the possibility that observers of the game, who generate the reputation of the interacting players, assign reputations without complete information about them has been neglected. Because an individual acts as an interacting player and as an observer on different occasions if indirect reciprocity is endogenously sustained in a society, the incompleteness of information may affect either role. We examine the game of indirect reciprocity when the reputations of players are not necessarily known to observers and to interacting players. We find that the trustful discriminator, which cooperates with good and unknown players and defects against bad players, realizes cooperative societies under seven social norms. Among the seven social norms, three of the four suspicious norms under which cooperation (defection) to unknown players leads to a good (bad) reputation enable cooperation down to a relatively small observation probability. In contrast, the three trustful norms under which both cooperation and defection to unknown players lead to a good reputation are relatively efficient. PMID:21829335

  12. Indirect techniques in nuclear astrophysics

    International Nuclear Information System (INIS)

    Mukhamedzhanov, A.M.; Tribble, R.E.; Blokhintsev, L.D.; Cherubini, S.; Spitaleri, C.; Kroha, V.; Nunes, F.M.

    2005-01-01

    It is very difficult or often impossible to measure in the lab conditions nuclear cross sections at astrophysically relevant energies. That is why different indirect techniques are used to extract astrophysical information. In this talk different experimental possibilities to get astrophysical information using radioactive and stable beams will be addressed. 1. The asymptotic normalization coefficient (ANC) method. 2. Radiative neutron captures are determined by the spectroscopic factors (SP). A new experimental technique to determine the neutron SPs will be addressed. 3. 'Trojan Horse' is another unique indirect method, which allows one to extract the astrophysical factors for direct and resonant nuclear reactions at astrophysically relevant energies. (author)

  13. Calorimetry at the international linear collider. From simulation to reality

    Energy Technology Data Exchange (ETDEWEB)

    Wattimena, Nanda

    2010-02-15

    Calorimetry plays a crucial role in ongoing and upcoming high-energy physics experiments. To build a powerful calorimetric system with a performance tailored to the expected physics signatures, demands dedicated research and development of new readout technologies as well as dedicated reconstruction algorithms. The presented design of a calorimetric system which meets the high demands of precision physics at the future linear collider ILC, follows the paradigm of particle ow. Particle ow is a reconstruction principle that relies on a calorimetric system with high spatial granularity. In the detector optimisation process, the development of hardware and software are interlinked and cannot be judged independently. This thesis addresses two different aspects of detector optimisation, a test of the detector design against one example physics scenario and the development of a stable calibration procedure. In the rst part, a gauge-mediated Supersymmetry breaking scenario is used to test the design of the electromagnetic calorimeter in a full detector simulation study. The reconstruction of the neutralino properties, each decaying into a photon and a gravitino, requires a good energy resolution, as well as excellent position and angular resolution. The error bounds on the neutralino mass is strongly linked to the energy resolution, while the position and angular reconstruction of neutral particles is essential for the determination of the neutralino lifetime. The second part of this thesis focuses on the calibration procedure for a prototype of the hadron calorimeter. 7608 novel photodetectors are operated and tested in this prototype. They are exposed to beams of well de ned particle type and energy. The calibration is tested with a detailed study of electromagnetic showers inside the cubic-metre-sized prototype, with special attention paid towards the non-linearity correction. (orig.)

  14. Calorimetry at the international linear collider. From simulation to reality

    International Nuclear Information System (INIS)

    Wattimena, Nanda

    2010-02-01

    Calorimetry plays a crucial role in ongoing and upcoming high-energy physics experiments. To build a powerful calorimetric system with a performance tailored to the expected physics signatures, demands dedicated research and development of new readout technologies as well as dedicated reconstruction algorithms. The presented design of a calorimetric system which meets the high demands of precision physics at the future linear collider ILC, follows the paradigm of particle ow. Particle ow is a reconstruction principle that relies on a calorimetric system with high spatial granularity. In the detector optimisation process, the development of hardware and software are interlinked and cannot be judged independently. This thesis addresses two different aspects of detector optimisation, a test of the detector design against one example physics scenario and the development of a stable calibration procedure. In the rst part, a gauge-mediated Supersymmetry breaking scenario is used to test the design of the electromagnetic calorimeter in a full detector simulation study. The reconstruction of the neutralino properties, each decaying into a photon and a gravitino, requires a good energy resolution, as well as excellent position and angular resolution. The error bounds on the neutralino mass is strongly linked to the energy resolution, while the position and angular reconstruction of neutral particles is essential for the determination of the neutralino lifetime. The second part of this thesis focuses on the calibration procedure for a prototype of the hadron calorimeter. 7608 novel photodetectors are operated and tested in this prototype. They are exposed to beams of well de ned particle type and energy. The calibration is tested with a detailed study of electromagnetic showers inside the cubic-metre-sized prototype, with special attention paid towards the non-linearity correction. (orig.)

  15. Silk I and Silk II studied by fast scanning calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cebe, Peggy; Partlow, Benjamin P.; Kaplan, David L.; Wurm, Andreas; Zhuravlev, Evgeny; Schick, Christoph

    2017-06-01

    Using fast scanning calorimetry (FSC), we investigated the glass transition and crystal melting of samples of B. mori silk fibroin containing Silk I and/or Silk II crystals. Due to the very short residence times at high temperatures during such measurements, thermal decomposition of silk protein can be significantly suppressed. FSC was performed at 2000 K/s using the Mettler Flash DSC1 on fibroin films with masses around 130–270 ng. Films were prepared with different crystalline fractions (ranging from 0.26 to 0.50) and with different crystal structures (Silk I, Silk II, or mixed) by varying the processing conditions. These included water annealing at different temperatures, exposure to 50% MeOH in water, or autoclaving. The resulting crystal structure was examined using wide angle X-ray scattering. Degree of crystallinity was evaluated from Fourier transform infrared (FTIR) spectroscopy and from analysis of the heat capacity increment at the glass transition temperature. Silk fibroin films prepared by water annealing at 25 °C were the least crystalline and had Silk I structure. FTIR and FSC studies showed that films prepared by autoclaving or 50% MeOH exposure were the most crystalline and had Silk II structure. Intermediate crystalline fraction and mixed Silk I/Silk II structures were found in films prepared by water annealing at 37 °C. FSC results indicate that Silk II crystals exhibit endotherms of narrower width and have higher mean melting temperature Tm(II) = 351 ± 2.6 °C, compared to Silk I crystals which melt at Tm(I) = 292 ± 3.8 °C. Films containing mixed Silk I/Silk II structure showed two clearly separated endothermic peaks. Evidence suggests that the two types of crystals melt separately and do not thermally interconvert on the extremely short time scale (0.065 s between onset and end of melting) of the FSC experiment.

  16. Laser-Driven Calorimetry Measurements of Petroleum and Biodiesel Fuels.

    Science.gov (United States)

    Presser, Cary; Nazarian, Ashot; Millo, Amit

    2018-02-01

    Thermochemical characteristics were determined for several National Institute of Standards and Technology standard-reference-material petroleum and biodiesel fuels, using a novel laser-heating calorimetry technique. Measurements focused on the sample thermal behavior, specific heat release rate, and total specific heat release. The experimental apparatus consists of a copper sphere-shaped reactor mounted within a chamber, along with laser-beam-steering optical components, gas-supply manifold, and a computer-controlled data-acquisition system. At the center of the reactor, liquid sample is injected onto a copper pan substrate that rests and is in contact with a fine-wire thermocouple. A second thermocouple is in contact with the inner reactor sphere surface. The reactor is heated from opposing sides by a continuous-wave, near-infrared laser to achieve nearly uniform sample temperature. The change in temperature with time (thermogram) is recorded for both thermocouples, and compared to a baseline thermogram (without liquid in the pan). The thermograms are then processed (using an equation for thermal energy conservation) for the thermochemical information of interest. The results indicated that the energy reaching the pan is dominated by radiative heat transfer processes, while the dominant thermal process for the reactor sphere is the stored (internal) thermal energy within the sphere material. Sufficient laser power is necessary to detect the fuel thermal-related characteristics, and the required power can differ from one fuel to another. With sufficient laser power, one can detect the preferential vaporization of the lighter and heavier fuel fractions. The total specific heat release obtained for the different conventional and biodiesel fuels used in this investigation were similar to the expected values available in the literature.

  17. Environmental effects of indirect subsidies

    International Nuclear Information System (INIS)

    Van Beers, C.P.; De Moor, A.P.G.; Van den Bergh, J.C.J.M.; Oosterhuis, F.H.

    2003-01-01

    The aim of the study on the title subject is to develop a transparent integrated method to determine and analyze the environmental impacts of indirect subsidies, applied in the sectors agriculture, energy, mobility, and tourism. From the results it appears that the hazardous effects of subsidies are big. Examples are milk, the regulating energy levy, and kerosene [nl

  18. Indirect searches for dark matter

    Indian Academy of Sciences (India)

    The current status of indirect searches for dark matter has been reviewed in a schematic way here. The main relevant experimental results of the recent years have been listed and the excitements and disappointments that their phenomenological interpretations in terms of almost-standard annihilating dark matter have ...

  19. Indirect methods in nuclear astrophysics

    International Nuclear Information System (INIS)

    Bertulani, C.A.; Shubhchintak; Mukhamedzhanov, A.; Kadyrov, A. S.; Kruppa, A.; Pang, D. Y.

    2016-01-01

    We discuss recent developments in indirect methods used in nuclear astrophysics to determine the capture cross sections and subsequent rates of various stellar burning processes, when it is difficult to perform the corresponding direct measurements. We discuss in brief, the basic concepts of Asymptotic Normalization Coefficients, the Trojan Horse Method, the Coulomb Dissociation Method, (d,p), and charge-exchange reactions. (paper)

  20. Indirect Reciprocity : A Field Experiment

    NARCIS (Netherlands)

    van Apeldoorn, J.; Schram, A.

    2016-01-01

    Indirect reciprocity involves cooperative acts towards strangers, either in response to their kindness to third parties (downstream) or after receiving kindness from others oneself (upstream). It is considered to be important for the evolution of cooperative behavior amongst humans. Though it has

  1. Indirect reciprocity with optional interactions.

    Science.gov (United States)

    Ghang, Whan; Nowak, Martin A

    2015-01-21

    Indirect reciprocity is a mechanism for the evolution of cooperation that is relevant for prosocial behavior among humans. Indirect reciprocity means that my behavior towards you also depends on what you have done to others. Indirect reciprocity is associated with the evolution of social intelligence and human language. Most approaches to indirect reciprocity assume obligatory interactions, but here we explore optional interactions. In any one round a game between two players is offered. A cooperator accepts a game unless the reputation of the other player indicates a defector. For a game to take place, both players must accept. In a game between a cooperator and a defector, the reputation of the defector is revealed to all players with probability Q. After a sufficiently large number of rounds the identity of all defectors is known and cooperators are no longer exploited. The crucial condition for evolution of cooperation can be written as hQB>1, where h is the average number of rounds per person and B=(b/c)-1 specifies the benefit-to-cost ratio. We analyze both stochastic and deterministic evolutionary game dynamics. We study two extensions that deal with uncertainty: hesitation and malicious gossip. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Application of calorimetry and thermodynamics to critical problems in materials science

    International Nuclear Information System (INIS)

    Atake, Tooru

    2009-01-01

    Calorimetry and thermodynamic studies have long been playing a very important role in the research fields of fundamental science and technology. Some topics and examples of thermodynamics studies are given, and the details are explained on the basis of the present author's experience, focusing attention to application of adiabatic calorimetry and thermodynamics to solve critical problems in materials science: (1) condensed gas calorimetry and third law entropy, (2) phase transition and polymorphism in simple molecular crystals, (3) incommensurate phase transitions, (4) particle size effects on the phase transitions in ferroelectric/ferroelastic crystals, (5) relaxor ferroelectrics and multi-ferroics, and some other topics in materials science and technology

  3. Application of prediction of equilibrium to servo-controlled calorimetry measurements

    International Nuclear Information System (INIS)

    Mayer, R.L. II

    1987-01-01

    Research was performed to develop an endpoint prediction algorithm for use with calorimeters operating in the digital servo-controlled mode. The purpose of this work was to reduce calorimetry measurement times while maintaining the high degree of precision and low bias expected from calorimetry measurements. Data from routine operation of two calorimeters were used to test predictive models at each stage of development against time savings, precision, and robustness criteria. The results of the study indicated that calorimetry measurement times can be significantly reduced using this technique. The time savings is, however, dependent on parameters in the digital servo-control algorithm and on packaging characteristics of measured items

  4. Resistive Plate Chambers for Imaging Calorimetry - the DHCAL

    CERN Document Server

    Repond, Jose

    2014-01-01

    The DHCAL, the Digital Hadron Calorimeter, is a prototype calorimeter based on Resistive Plate Chambers (RPCs). The design emphasizes the imaging capabilities of the detector in an effort to optimize the calorimeter for the application of Particle Flow Algorithms (PFAs) to the reconstruction of hadronic jet energies in a colliding beam environment. The readout of the chambers is segmented into 1 x 1 cm2 pads, each read out with a 1-bit (single threshold) resolution. The prototype with approximately 500,000 readout channels underwent extensive testing in both the Fermilab and CERN test beams. This talk presents preliminary findings from the analysis of data collected at the test beams.

  5. Indirect taxation in the European Union

    OpenAIRE

    Ene, Sebastian; Micuda, Dan

    2007-01-01

    Indirect taxes are levied on the production and consumption of goods and services. They influence the retail price, and hence affect patterns of trade and consumption. Indirect taxes are ultimately paid by the final consumer. Sales and turnover taxes, excise duties and tariffs are the basic indirect taxes. In contrast with direct taxes, indirect taxes are seldom progressive. The principles for the levying of these taxes will be considered before the analysis of indirect taxes.

  6. Parallelism between gradient temperature raman spectroscopy and differential scanning calorimetry results

    Science.gov (United States)

    Temperature dependent Raman spectroscopy (TDR) applies the temperature gradients utilized in differential scanning calorimetry (DSC) to Raman spectroscopy, providing a straightforward technique to identify molecular rearrangements that occur just prior to phase transitions. Herein we apply TDR and D...

  7. Electronic Commerce and Indirect Taxation

    OpenAIRE

    Watanabe, Satoshi

    2001-01-01

    This paper considers the reason why indirect tax issues arise in the context of electronic commerce and discusses relevant issues. To do so, the paper presents a simple framework to understand and examine these issues in the international context. It also identifies common and different issues of the VAT system and the RST system. It demonstrates that an emerging solution proposed in the context of the VAT system can be affected with difficult problems that were regarded to be problems of the...

  8. [A Distal Bile Duct Carcinoma Patient Who Underwent Surgical Resection for Liver Metastasis].

    Science.gov (United States)

    Komiyama, Sosuke; Izumiya, Yasuhito; Kimura, Yu; Nakashima, Shingo; Kin, Syuichi; Kawakami, Sadao

    2018-03-01

    A 70-year-old man with distal bile duct carcinoma underwent a subtotal stomach-preserving pancreaticoduodenectomy without adjuvant chemotherapy. One and a half years after the surgery, elevated levels of serum SPan-1(38.1 U/mL)were observed and CT scans demonstrated a solitary metastasis, 25mm in size, in segment 8 of the liver. The patient received 2 courses of gemcitabine-cisplatin combination chemotherapy. No new lesions were detected after chemotherapy and the patient underwent a partial liver resection of segment 8. The pathological examination revealed a metachronous distant metastasis originating from the bile duct carcinoma. Subsequently, the patient received S-1 adjuvant chemotherapy for 6 months. Following completion of all therapies, the patient survived without tumor recurrence for 3 years and 10 months after the initial operation. Thus, surgical interventions might be effective in improving prognosis among selected patients with postoperative liver metastasis of bile duct carcinoma.

  9. Enzyme-catalyzed and binding reaction kinetics determined by titration calorimetry.

    Science.gov (United States)

    Hansen, Lee D; Transtrum, Mark K; Quinn, Colette; Demarse, Neil

    2016-05-01

    Isothermal calorimetry allows monitoring of reaction rates via direct measurement of the rate of heat produced by the reaction. Calorimetry is one of very few techniques that can be used to measure rates without taking a derivative of the primary data. Because heat is a universal indicator of chemical reactions, calorimetry can be used to measure kinetics in opaque solutions, suspensions, and multiple phase systems and does not require chemical labeling. The only significant limitation of calorimetry for kinetic measurements is that the time constant of the reaction must be greater than the time constant of the calorimeter which can range from a few seconds to a few minutes. Calorimetry has the unique ability to provide both kinetic and thermodynamic data. This article describes the calorimetric methodology for determining reaction kinetics and reviews examples from recent literature that demonstrate applications of titration calorimetry to determine kinetics of enzyme-catalyzed and ligand binding reactions. A complete model for the temperature dependence of enzyme activity is presented. A previous method commonly used for blank corrections in determinations of equilibrium constants and enthalpy changes for binding reactions is shown to be subject to significant systematic error. Methods for determination of the kinetics of enzyme-catalyzed reactions and for simultaneous determination of thermodynamics and kinetics of ligand binding reactions are reviewed. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Dysphagia among Adult Patients who Underwent Surgery for Esophageal Atresia at Birth

    Directory of Open Access Journals (Sweden)

    Valérie Huynh-Trudeau

    2015-01-01

    Full Text Available BACKGROUND: Clinical experiences of adults who underwent surgery for esophageal atresia at birth is limited. There is some evidence that suggests considerable long-term morbidity, partly because of dysphagia, which has been reported in up to 85% of adult patients who undergo surgery for esophageal atresia. The authors hypothesized that dysphagia in this population is caused by dysmotility and/or anatomical anomalies.

  11. Effect of using pump on postoperative pleural effusion in the patients that underwent CABG

    Directory of Open Access Journals (Sweden)

    Mehmet Özülkü

    2015-08-01

    Full Text Available Abstract Objective: The present study investigated effect of using pump on postoperative pleural effusion in patients who underwent coronary artery bypass grafting. Methods: A total of 256 patients who underwent isolated coronary artery bypass grafting surgery in the Cardiovascular Surgery clinic were enrolled in the study. Jostra-Cobe (Model 043213 105, VLC 865, Sweden heart-lung machine was used in on-pump coronary artery bypass grafting. Off-pump coronary artery bypass grafting was performed using Octopus and Starfish. Proximal anastomoses to the aorta in both on-pump and off-pump techniques were performed by side clamps. The patients were discharged from the hospital between postoperative day 6 and day 11. Results: The incidence of postoperative right pleural effusion and bilateral pleural effusion was found to be higher as a count in Group 1 (on-pump as compared to Group 2 (off-pump. But the difference was not statistically significant [P>0.05 for right pleural effusion (P=0.893, P>0.05 for bilateral pleural effusion (P=0.780]. Left pleural effusion was encountered to be lower in Group 2 (off-pump. The difference was found to be statistically significant (P<0.05, P=0.006. Conclusion: Under the light of these results, it can be said that left pleural effusion is less prevalent in the patients that underwent off-pump coronary artery bypass grafting when compared to the patients that underwent on-pump coronary artery bypass grafting.

  12. Incidence of Bradycardia and Outcomes of Patients Who Underwent Orbital Atherectomy Without a Temporary Pacemaker.

    Science.gov (United States)

    Lee, Michael S; Nguyen, Heajung; Shlofmitz, Richard

    2017-02-01

    We analyzed the incidence of bradycardia and the safety of patients with severely calcified coronary lesions who underwent orbital atherectomy without the insertion of a temporary pacemaker. The presence of severely calcified coronary lesions can increase the complexity of percutaneous coronary intervention due to the difficulty in advancing and optimally expanding the stent. High-pressure inflations to predilate calcified lesions may cause angiographic complications like perforation and dissection. Suboptimal stent expansion is associated with stent thrombosis and restenosis. Orbital atherectomy safely and effectively modifies calcified plaque to facilitate optimal stent expansion. The incidence of bradycardia in orbital atherectomy is unknown. Fifty consecutive patients underwent orbital atherectomy from February 2014 to September 2016 at our institution, none of whom underwent insertion of a temporary pacemaker. The final analysis included 47 patients in this retrospective study as 3 patients were excluded because of permanent pacemaker implantation. The primary endpoint was significant bradycardia, defined as bradycardia requiring emergent pacemaker placement or a heart rate pacemaker appears to be safe.

  13. Comparison of Voice Quality Between Patients Who Underwent Inferior Turbinoplasty or Radiofrequency Cauterization.

    Science.gov (United States)

    Göker, Ayşe Enise; Aydoğdu, İmran; Saltürk, Ziya; Berkiten, Güler; Atar, Yavuz; Kumral, Tolgar Lütfi; Uyar, Yavuz

    2017-01-01

    The aim of this study was to analyze and compare the vocal quality in patients who underwent either submucosal turbinectomy or radiofrequency cauterization. In this study, we enrolled 60 patients diagnosed with inferior concha hypertrophy. These patients were divided into two groups by using computer program "Research Randomizer." Of the 60 patients, 30 underwent submucosal inferior turbinoplasty and 30 underwent radiofrequency cauterization. The control group was composed of 30 healthy adults with no nasal or upper aerodigestive system pathology. The patients were checked at weeks 1, 2, and 4. Voice records were taken before the procedure and at week 4 postprocedure. The mean age of patients in the inferior turbinoplasty group was 29.4 years (range: 19-42 years); in the radiofrequency group, it was 30.30 years (range: 18-50 years). There was no statistical difference in age between groups. In the inferior turbinoplasty group, there were 16 male and 14 female patients, and in the radiofrequency group, there were 13 male and 17 female patients. There was no significant difference in the number of males and females between groups. Voice professionals, especially singers, actors, and actresses, should be informed about possible voice changes before undergoing endonasal surgery because these individuals are more sensitive to changes in resonance organs. We believe that voice quality should be regarded as a highly important parameter when measuring the success of endonasal surgery. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  14. Evolution of elderly patients who underwent cardiac surgery with cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Alain Moré Duarte

    2016-01-01

    Full Text Available Introduction: There is a steady increase in the number of elderly patients with severe cardiovascular diseases who require a surgical procedure to recover some quality of life that allows them a socially meaningful existence, despite the risks.Objectives: To analyze the behavior of elderly patients who underwent cardiac surgery with cardiopulmonary bypass.Method: A descriptive, retrospective, cross-sectional study was conducted with patients over 65 years of age who underwent surgery at the Cardiocentro Ernesto Che Guevara, in Santa Clara, from January 2013 to March 2014.Results: In the study, 73.1% of patients were men; and there was a predominance of subjects between 65 and 70 years of age, accounting for 67.3%. Coronary artery bypass graft was the most prevalent type of surgery and had the longest cardiopulmonary bypass times. Hypertension was present in 98.1% of patients. The most frequent postoperative complications were renal dysfunction and severe low cardiac output, with 44.2% and 34.6% respectively.Conclusions: There was a predominance of men, the age group of 65 to 70 years, hypertension, and patients who underwent coronary artery bypass graft with prolonged cardiopulmonary bypass. Renal dysfunction was the most frequent complication.

  15. Acute myocardial infarctation in patients with critical ischemia underwent lower limb revascularization

    Directory of Open Access Journals (Sweden)

    Esdras Marques Lins

    2013-12-01

    Full Text Available BACKGROUND: Atherosclerosis is the main cause of peripheral artery occlusive disease (PAOD of the lower limbs. Patients with PAOD often also have obstructive atherosclerosis in other arterial sites, mainly the coronary arteries. This means that patients who undergo infrainguinal bypass to treat critical ischemia have a higher risk of AMI. There are, however, few reports in the literature that have assessed this risk properly. OBJECTIVE: The aim of this study was to determine the incidence of acute myocardial infarction in patients who underwent infrainguinal bypass to treat critical ischemia of the lower limbs caused by PAOD. MATERIAL AND METHODS: A total of 64 patients who underwent 82 infrainguinal bypass operations, from February 2011 to July 2012 were studied. All patients had electrocardiograms and troponin I blood assays during the postoperative period (within 72 hours. RESULTS: There were abnormal ECG findings and elevated blood troponin I levels suggestive of AMI in five (6% of the 82 operations performed. All five had conventional surgery. The incidence of AMI as a proportion of the 52 conventional surgery cases was 9.6%. Two patients died. CONCLUSION: There was a 6% AMI incidence among patients who underwent infrainguinal bypass due to PAOD. Considering only cases operated using conventional surgery, the incidence of AMI was 9.6%.

  16. Picowatt Resolution Calorimetry for Micro and Nanoscale Energy Transport Studies

    Science.gov (United States)

    Sadat, Seid H.

    Precise quantification of energy transport is key to obtaining insights into a wide range of phenomena across various disciplines including physics, chemistry, biology and engineering. This thesis describes technical advancements into heat-flow calorimetry which enable measurement of energy transport at micro and nanoscales with picowatt resolution. I have developed two types of microfabricated calorimeter devices and demonstrated single digit picowatt resolution at room temperature. Both devices incorporate two distinct features; an active area isolated by a thermal conductance (GTh) of less than 1 microW/K and a high resolution thermometer with temperature resolution (DeltaTres) in the micro kelvin regime. These features enable measurements of heat currents (q) with picowatt resolution (q= Th xDeltaTres). In the first device the active area is suspended via silicon nitride beams with excellent thermal isolation (~600 nW/K) and a bimaterial cantilever (BMC) thermometer with temperature resolution of ~6 microK. Taken together this design enabled calorimetric measurements with 4 pW resolution. In the second device, the BMC thermometry technique is replaced by a high-resolution resistance thermometry scheme. A detailed noise analysis of resistance thermometers, confirmed by experimental data, enabled me to correctly predict the resolution of different measurement schemes and propose techniques to achieve an order of magnitude improvement in the resolution of resistive thermometers. By incorporating resistance thermometers with temperature resolution of ~30 microK, combined with a thermal isolation of ~150 nW/K, I demonstrated an all-electrical calorimeter device with a resolution of ~ 5 pW. Finally, I used these calorimeters to study Near-Field Radiative Heat Transfer (NF-RHT). Using these devices, we studied--for the first time--the effect of film thickness on the NF-RHT between two dielectric surfaces. We showed that even a very thin film (~50 nm) of silicon

  17. Silk I and Silk II studied by fast scanning calorimetry.

    Science.gov (United States)

    Cebe, Peggy; Partlow, Benjamin P; Kaplan, David L; Wurm, Andreas; Zhuravlev, Evgeny; Schick, Christoph

    2017-06-01

    Using fast scanning calorimetry (FSC), we investigated the glass transition and crystal melting of samples of B. mori silk fibroin containing Silk I and/or Silk II crystals. Due to the very short residence times at high temperatures during such measurements, thermal decomposition of silk protein can be significantly suppressed. FSC was performed at 2000K/s using the Mettler Flash DSC1 on fibroin films with masses around 130-270ng. Films were prepared with different crystalline fractions (ranging from 0.26 to 0.50) and with different crystal structures (Silk I, Silk II, or mixed) by varying the processing conditions. These included water annealing at different temperatures, exposure to 50%MeOH in water, or autoclaving. The resulting crystal structure was examined using wide angle X-ray scattering. Degree of crystallinity was evaluated from Fourier transform infrared (FTIR) spectroscopy and from analysis of the heat capacity increment at the glass transition temperature. Silk fibroin films prepared by water annealing at 25°C were the least crystalline and had Silk I structure. FTIR and FSC studies showed that films prepared by autoclaving or 50%MeOH exposure were the most crystalline and had Silk II structure. Intermediate crystalline fraction and mixed Silk I/Silk II structures were found in films prepared by water annealing at 37°C. FSC results indicate that Silk II crystals exhibit endotherms of narrower width and have higher mean melting temperature T m (II)=351±2.6°C, compared to Silk I crystals which melt at T m (I)=292±3.8°C. Films containing mixed Silk I/Silk II structure showed two clearly separated endothermic peaks. Evidence suggests that the two types of crystals melt separately and do not thermally interconvert on the extremely short time scale (0.065s between onset and end of melting) of the FSC experiment. Silkworm silk is a naturally occurring biomaterial. The fibroin component of silk forms two types of crystals. Silk properties depend upon the

  18. Factors related to postoperative pain among patients who underwent radiofrequency ablation of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Hsieh, Y.-C.; Yap, Y.-S.; Hung, C.-H.; Chen, C.-H.; Lu, S.-N.; Wang, J.-H.

    2013-01-01

    Aim: To evaluate the incidence and associated factors of postoperative intense pain and haemodynamic changes during radiofrequency ablation of hepatocellular carcinoma. Materials and methods: A total of 123 consecutive hepatocellular carcinoma patients who underwent radiofrequency ablation were prospectively recruited. Patient factors, tumour characteristics, procedural factors, intraoperative haemodynamic changes, complications, postoperative events, laboratory values before and after ablation, and postoperative pain were evaluated. Postoperative pain was scored using a visual analogue scale after the procedure. Results: The mean age of the patients was 65.6 ± 9.6 years. In multiple logistic regression analysis, patients who underwent general anaesthesia [odds ratio (95% CI): 2.68 (1.23–5.81); p = 0.013] and had more postoperative nausea and vomiting episodes [3.10 (1.11–8.63); p = 0.036] were associated with intense pain. These findings remain robust after propensity score matching. For mean difference values between before and after RFA, higher in change in aspartate transaminase (p = 0.026), alanine transaminase (p = 0.016) and white blood cell count (p = 0.015), and lower in change in haemoglobin (p = 0.009) were also correlated with intense pain. There was no significant difference in haemodynamic changes between the general anaesthesia and local anaesthesia group during ablation. Conclusion: General anaesthesia, postoperative nausea and vomiting, and laboratory factors were associated with postoperative intense pain in patients who underwent radiofrequency ablation. Counselling and modification of analgesics should be considered in patients with related factors for intense pain

  19. Safety and Tolerability of Transitioning from Cangrelor to Ticagrelor in Patients Who Underwent Percutaneous Coronary Intervention.

    Science.gov (United States)

    Badreldin, Hisham A; Carter, Danielle; Cook, Bryan M; Qamar, Arman; Vaduganathan, Muthiah; Bhatt, Deepak L

    2017-08-01

    The 3 phase 3 CHAMPION (Cangrelor vs Standard Therapy to Achieve Optimal Management of Platelet Inhibition) trials collectively demonstrated the safety of transitioning from cangrelor, a potent, parenteral rapidly-acting P2Y 12 inhibitor, to clopidogrel in patients who underwent percutaneous coronary intervention (PCI). However, variation in timing of therapy, site-specific binding, and drug half-lives may theoretically complicate switching to other oral P2Y 12 inhibitors. Since regulatory approval, limited data are available regarding the "real-world" safety and tolerability of transitioning to these more potent oral P2Y 12 antagonists. From November 2015 to January 2017, we evaluated the clinical profiles and efficacy and safety outcomes in cangrelor-treated patients who underwent PCI transitioned to clopidogrel (n = 42) or ticagrelor (n = 82) at a large, tertiary care center. Most patients receiving cangrelor underwent PCI with a drug-eluting stent for acute coronary syndrome via a radial approach in the background of unfractionated heparin. Stent thrombosis within 48 hours was rare and occurred in 1 patient treated with ticagrelor. Global Use of Strategies to Open Occluded Coronary Arteries-defined bleeding occurred in 20% of patients switched to ticagrelor and 29% of patients switched to clopidogrel, but none were severe or life-threatening. In conclusion, rates of stent thrombosis and severe/life-threatening bleeding were low and comparable with those identified in the CHAMPION program, despite use of more potent oral P2Y 12 inhibition. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Surrogate pregnancy in a patient who underwent radical hysterectomy and bilateral transposition of ovaries.

    Science.gov (United States)

    Azem, Foad; Yovel, Israel; Wagman, Israel; Kapostiansky, Rita; Lessing, Joseph B; Amit, Ami

    2003-05-01

    To evaluate IVF-surrogate pregnancy in a patient with ovarian transposition after radical hysterectomy for carcinoma of the cervix. Case report. A maternity hospital in Tel Aviv that is a major tertiary care and referral center. A 29-year-old woman who underwent Wertheim's hysterectomy for carcinoma of the uterine cervix and ovarian transposition before total pelvic irradiation. Standard IVF treatment, transabdominal oocyte retrieval, and transfer to surrogate mother. Outcome of IVF cycle. A twin pregnancy in the first cycle. This is the second reported case of controlled ovarian stimulation and oocyte retrieval performed on a transposed ovary.

  1. [A Case of Ascending Colon Cancer with Lynch Syndrome Who Underwent XELOX Adjuvant Chemotherapy].

    Science.gov (United States)

    Takase, Koki; Murata, Kohei; Kagawa, Yoshinori; Nose, Yohei; Kawai, Kenji; Sakamoto, Takuya; Naito, Atsushi; Murakami, Kohei; Katsura, Yoshiteru; Omura, Yoshiaki; Takeno, Atsushi; Nakatsuka, Shinichi; Takeda, Yutaka; Kato, Takeshi; Tamura, Shigeyuki

    2018-01-01

    Lynch syndrome is an inherited syndrome with the development of the colorectal and various other cancers. Lynch syndrome is caused by mutations in the mismatch repair genes. A 33 year-old male underwent XELOX adjuvant chemotherapy for ascending colon cancer with Lynch syndrome. Although efficacy of 5-FU is not demonstrated in Lynch syndrome, MOSAIC trial had suggested a benefit from FOLFOX compared with 5-FU in patients who have colorectal cancer with Lynch syndrome. Oxaliplatin-based adjuvant chemotherapy can be a therapeutic option for colorectal cancer in lynch syndrome patients.

  2. Indirect detection of dark matter

    International Nuclear Information System (INIS)

    Pieri, L.

    2008-01-01

    In the Cold Dark Matter scenario, the Dark Matter particle candidate may be a Weakly Interacting Massive Particle (Wimp). Annihilation of two Wimps in local or cosmological structures would result in the production of a number of standard model particles such as photons, leptons and baryons which could be observed with the presently available or future experiments such as the Pamela or Glast satellites or the Cherenkov Telescopes. In this work we review the status-of-the-art of the theoretical and phenomenological studies about the possibility of indirect detection of signals coming from Wimp annihilation.

  3. Indirect detection of dark matter

    International Nuclear Information System (INIS)

    Carr, J; Lamanna, G; Lavalle, J

    2006-01-01

    This article is an experimental review of the status and prospects of indirect searches for dark matter. Experiments observe secondary particles such as positrons, antiprotons, antideuterons, gamma-rays and neutrinos which could originate from annihilations of dark matter particles in various locations in the galaxy. Data exist from some experiments which have been interpreted as hints of evidence for dark matter. These data and their interpretations are reviewed together with the new experiments which are planned to resolve the puzzles and make new measurements which could give unambiguous results

  4. Indirect Medical Education and Disproportionate Share Adj...

    Data.gov (United States)

    U.S. Department of Health & Human Services — Indirect Medical Education and Disproportionate Share Adjustments to Medicare Inpatient Payment Rates The indirect medical education (IME) and disproportionate share...

  5. HLA-G regulatory haplotypes and implantation outcome in couples who underwent assisted reproduction treatment.

    Science.gov (United States)

    Costa, Cynthia Hernandes; Gelmini, Georgia Fernanda; Wowk, Pryscilla Fanini; Mattar, Sibelle Botogosque; Vargas, Rafael Gustavo; Roxo, Valéria Maria Munhoz Sperandio; Schuffner, Alessandro; Bicalho, Maria da Graça

    2012-09-01

    The role of HLA-G in several clinical conditions related to reproduction has been investigated. Important polymorphisms have been found within the 5'URR and 3'UTR regions of the HLA-G promoter. The aim of the present study was to investigate 16 SNPs in the 5'URR and 14-bp insertion/deletion (ins/del) polymorphism located in the 3'UTR region of the HLA-G gene and its possible association with the implantation outcome in couples who underwent assisted reproduction treatments (ART). The case group was composed of 25 ART couples. Ninety-four couples with two or more term pregnancies composed the control group. Polymorphism haplotype frequencies of the HLA-G were determined for both groups. The Haplotype 5, Haplotype 8 and Haplotype 11 were absolute absence in ART couples. The HLA-G*01:01:02a, HLA-G*01:01:02b alleles and the 14-bp ins polymorphism, Haplotype 2, showed an increased frequency in case women and similar distribution between case and control men. However, this susceptibility haplotype is significantly presented in case women and in couple with failure implantation after treatment, which led us to suggest a maternal effect, associated with this haplotype, once their presence in women is related to a higher number of couples who underwent ART. Copyright © 2012. Published by Elsevier Inc.

  6. Sarcopenia: a new predictor of postoperative complications for elderly gastric cancer patients who underwent radical gastrectomy.

    Science.gov (United States)

    Zhou, Chong-Jun; Zhang, Feng-Min; Zhang, Fei-Yu; Yu, Zhen; Chen, Xiao-Lei; Shen, Xian; Zhuang, Cheng-Le; Chen, Xiao-Xi

    2017-05-01

    A geriatric assessment is needed to identify high-risk elderly patients with gastric cancer. However, the current geriatric assessment has been considered to be either time-consuming or subjective. The present study aimed to investigate the predictive effect of sarcopenia on the postoperative complications for elderly patients who underwent radical gastrectomy. We conducted a prospective study of patients who underwent radical gastrectomy from August 2014 to December 2015. Computed tomography-assessed lumbar skeletal muscle, handgrip strength, and gait speed were measured to define sarcopenia. Sarcopenia was present in 69 of 240 patients (28.8%) and was associated with lower body mass index, lower serum albumin, lower hemoglobin, and higher nutritional risk screening 2002 scores. Postoperative complications significantly increased in the sarcopenic patients (49.3% versus 24.6%, P sarcopenia (odds ratio: 2.959, 95% CI: 1.629-5.373, P Sarcopenia, presented as a new geriatric assessment factor, was a strong and independent risk factor for postoperative complications of elderly patients with gastric cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Effect of different pneumoperitoneum pressure on stress state in patients underwent gynecological laparoscopy

    Directory of Open Access Journals (Sweden)

    Ai-Yun Shen

    2016-10-01

    Full Text Available Objective: To observe the effect of different CO2 pneumoperitoneum pressure on the stress state in patients underwent gynecological laparoscopy. Methods: A total of 90 patients who were admitted in our hospital from February, 2015 to October, 2015 for gynecological laparoscopy were included in the study and divided into groups A, B, and C according to different CO2 pneumoperitoneum pressure. The changes of HR, BP, and PetCO2 during the operation process in the three groups were recorded. The changes of stress indicators before operation (T0, 30 min during operation (T1, and 12 h after operation (T2 were compared. Results: The difference of HR, BP, and PetCO2 levels before operation among the three groups was not statistically significant (P>0.05. HR, BP, and PetCO2 levels 30 min after pneumoperitoneum were significantly elevated when compared with before operation (P0.05. PetCO2 level 30 min after pneumoperitoneum in group B was significantly higher than that in group A (P0.05. Conclusions: Low pneumoperitoneum pressure has a small effect on the stress state in patients underwent gynecological laparoscopy, will not affect the surgical operation, and can obtain a preferable muscular relaxation and vision field; therefore, it can be selected in preference.

  8. Circulating S100B and Adiponectin in Children Who Underwent Open Heart Surgery and Cardiopulmonary Bypass

    Directory of Open Access Journals (Sweden)

    Alessandro Varrica

    2015-01-01

    Full Text Available Background. S100B protein, previously proposed as a consolidated marker of brain damage in congenital heart disease (CHD newborns who underwent cardiac surgery and cardiopulmonary bypass (CPB, has been progressively abandoned due to S100B CNS extra-source such as adipose tissue. The present study investigated CHD newborns, if adipose tissue contributes significantly to S100B serum levels. Methods. We conducted a prospective study in 26 CHD infants, without preexisting neurological disorders, who underwent cardiac surgery and CPB in whom blood samples for S100B and adiponectin (ADN measurement were drawn at five perioperative time-points. Results. S100B showed a significant increase from hospital admission up to 24 h after procedure reaching its maximum peak (P0.05 have been found all along perioperative monitoring. ADN/S100B ratio pattern was identical to S100B alone with the higher peak at the end of CPB and remained higher up to 24 h from surgery. Conclusions. The present study provides evidence that, in CHD infants, S100B protein is not affected by an extra-source adipose tissue release as suggested by no changes in circulating ADN concentrations.

  9. Indirect costs of rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Filip Raciborski

    2015-12-01

    Full Text Available It is estimated that in Poland about 400,000 persons in general suffer from inflammatory joint diseases, including rheumatoid arthritis (RA. Epidemiological surveys documenting the frequency and disturbance of musculoskeletal disorders in the Polish population are few in number. Most of the estimations are based on epidemiological data from other countries (prevalence of 0.5–1%. According to the data of the National Health Fund in Poland 135,000–157,000 persons in total are treated because of rheumatoid arthritis per year [ICD10 (International Statistical Classification of Diseases and Related Health Problems: M05, M06]. In the case of this group of diseases indirect costs significantly outweigh the direct costs. Indirect costs increase together with activity level of the disease. The cost analysis of productivity loss of RA patients indicates that sickness absenteeism and informal care are the most burdensome. At the national level it amounts in total from 1.2 billion to 2.8 billion PLN per year, depending on the method of analysis. These costs could be significantly reduced through early diagnosis and introduction of effective treatment.

  10. Do infants detect indirect reciprocity?

    Science.gov (United States)

    Meristo, Marek; Surian, Luca

    2013-10-01

    In social interactions involving indirect reciprocity, agent A acts prosocially towards B and this prompts C to act prosocially towards A. This happens because A's actions enhanced its reputation in the eyes of third parties. Indirect reciprocity may have been of central importance in the evolution of morality as one of the major mechanisms leading to the selection of helping and fair attitudes. Here we show that 10-month-old infants expect third parties to act positively towards fair donors who have distributed attractive resources equally between two recipients, rather than toward unfair donors who made unequal distributions. Infants' responses were dependent on the reciprocator's perceptual exposure to previous relevant events: they expected the reciprocator to reward the fair donor only when it had seen the distributive actions performed by the donors. We propose that infants were able to generate evaluations of agents that were based on the fairness of their distributive actions and to generate expectations about the social preferences of informed third parties. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Indirect reciprocity with trinary reputations.

    Science.gov (United States)

    Tanabe, Shoma; Suzuki, Hideyuki; Masuda, Naoki

    2013-01-21

    Indirect reciprocity is a reputation-based mechanism for cooperation in social dilemma situations when individuals do not repeatedly meet. The conditions under which cooperation based on indirect reciprocity occurs have been examined in great details. Most previous theoretical analysis assumed for mathematical tractability that an individual possesses a binary reputation value, i.e., good or bad, which depends on their past actions and other factors. However, in real situations, reputations of individuals may be multiple valued. Another puzzling discrepancy between the theory and experiments is the status of the so-called image scoring, in which cooperation and defection are judged to be good and bad, respectively, independent of other factors. Such an assessment rule is found in behavioral experiments, whereas it is known to be unstable in theory. In the present study, we fill both gaps by analyzing a trinary reputation model. By an exhaustive search, we identify all the cooperative and stable equilibria composed of a homogeneous population or a heterogeneous population containing two types of players. Some results derived for the trinary reputation model are direct extensions of those for the binary model. However, we find that the trinary model allows cooperation under image scoring under some mild conditions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Indirect Cost Reimbursement: An Industrial View.

    Science.gov (United States)

    Bolton, Robert

    1987-01-01

    The meaning of indirect costs in an industrial environment is discussed. Other factors considered are corporate policies; nature of work being supported; the uniqueness of the work; who is doing the negotiating for industry; and indirect rates. Suggestions are offered for approaches to indirect cost reimbursement. (Author/MLW)

  13. Language shifts in free indirect discourse

    NARCIS (Netherlands)

    Maier, Emar

    Free indirect discourse is a way of reporting what a protagonist thinks or says that is distinct from both direct and indirect discourse. In particular, while pronouns and tenses are presented from the narrator's perspective, as in indirect discourse, other indexical and expressive elements reflect

  14. Directe en indirecte werknemersparticipatie in Europa

    NARCIS (Netherlands)

    van Houten, Gijs; Akkerman, Agnes; Sluiter, Roderick; Jansen, Giedo; Vermeylen, Greet

    2016-01-01

    This study looks at different forms of direct and indirect employee participation in the EU. The research questions are: (1) which forms of direct and indirect employee participation can we distinguish?; (2) to what extent do forms of direct and indirect employee participation coincide within

  15. Evaluation of the amorphous content of lactose by solution calorimetry and Raman spectroscopy.

    Science.gov (United States)

    Katainen, Erja; Niemelä, Pentti; Harjunen, Päivi; Suhonen, Janne; Järvinen, Kristiina

    2005-11-15

    Solution calorimetry can be used to determine the amorphous content of a compound when the solubility and dissolution rate of the compound in the chosen solvent are reasonably high. Sometimes, it can be difficult find a solvent in which a sample is freely soluble. The present study evaluated the use of solution calorimetry for the assessment of the amorphous content of a sample that is poorly soluble in a solvent. Physical mixtures of lactose and spray-dried lactose samples (the amorphous content varied from 0 to 100%) were analyzed by a solution calorimeter and the results were compared with Raman spectroscopy determinations. The heat of solvation of the samples was determined by solution calorimetry in organic solvents MeOH, EtOH, ACN, THF, acetone (400mg sample/100ml solvent). Lactose is virtually insoluble in ACN, THF and acetone and very slightly soluble in EtOH and MeOH. The amorphous content of the samples could not be determined by solution calorimetry in EtOH, ACN, THF or acetone. However, an excellent correlation was observed between the heat of solvation and the amorphous content of the samples in MeOH. Furthermore, the heat of solvation values of the samples in MeOH showed a linear correlation with the Raman quantifications. Therefore, our results demonstrate that solution calorimetry may represent a rapid and simple method for determining the amorphous content also in samples that are not freely soluble in the solvent.

  16. Outcome of Patients Underwent Emergency Department Thoracotomy and Its Predictive Factors

    Directory of Open Access Journals (Sweden)

    Shahram Paydar

    2014-08-01

    Full Text Available Introduction: Emergency department thoracotomy (EDT may serve as the last survival chance for patients who arrive at hospital in extremis. It is considered as an effective tool for improvement of traumatic patients’ outcome. The present study was done with the goal of assessing the outcome of patients who underwent EDT and its predictive factors. Methods: In the present study, medical charts of 50 retrospective and 8 prospective cases underwent emergency department thoracotomy (EDT were reviewed during November 2011 to June 2013. Comparisons between survived and died patients were performed by Mann-Whitney U test and the predictive factors of EDT outcome were measured using multivariate logistic regression analysis. P < 0.05 considered statistically significant. Results: Fifty eight cases of EDT were enrolled (86.2% male. The mean age of patients was 43.27±19.85 years with the range of 18-85. The mean time duration of CPR was recorded as 37.12±12.49 minutes. Eleven cases (19% were alive to be transported to OR (defined as ED survived. The mean time of survival in ED survived patients was 223.5±450.8 hours. More than 24 hours survival rate (late survived was 6.9% (4 cases. Only one case (1.7% survived to discharge from hospital (mortality rate=98.3%. There were only a significant relation between ED survival and SBP, GCS, CPR duration, and chest trauma (p=0.04. The results demonstrated that initial SBP lower than 80 mmHg (OR=1.03, 95% CI: 1.001-1.05, p=0.04 and presence of chest trauma (OR=2.6, 95% CI: 1.75-3.16, p=0.02 were independent predictive factors of EDT mortality. Conclusion: The findings of the present study showed that the survival rate of trauma patients underwent EDT was 1.7%. In addition, it was defined that falling systolic blood pressure below 80 mmHg and blunt trauma of chest are independent factors that along with poor outcome.

  17. Correlation between location of transposed ovary and function in cervical cancer patients who underwent radical hysterectomy.

    Science.gov (United States)

    Yoon, Aera; Lee, Yoo-Young; Park, Won; Huh, Seung Jae; Choi, Chel Hun; Kim, Tae-Joong; Lee, Jeong-Won; Kim, Byoung-Gie; Bae, Duk-Soo

    2015-05-01

    The study investigated the association between the location of transposed ovaries and posttreatment ovarian function in patients with early cervical cancer (IB1-IIA) who underwent radical hysterectomy and ovarian transposition with or without adjuvant therapies. Retrospective medical records were reviewed to enroll the patients with early cervical cancer who underwent ovarian transposition during radical hysterectomy at Samsung Medical Center between July 1995 and July 2012. Serum follicle-stimulating hormone (FSH) level was used as a surrogate marker for ovarian function. Twenty-one patients were enrolled. The median age and body mass index (BMI) were 31 years (range, 24-39 years) and 21.3 kg/m² (range, 17.7-31.2 kg/m²), respectively. The median serum FSH level after treatment was 7.9 mIU/mL (range, 2.4-143.4 mIU/mL). The median distance from the iliac crest to transposed ovaries on erect plain abdominal x-ray was 0.5 cm (range, -2.7 to 5.2 cm). In multivariate analysis, posttreatment serum FSH levels were significantly associated with the location of transposed ovaries (β = -8.1, P = 0.032), concurrent chemoradiation (CCRT) as an adjuvant therapy (β = 71.08, P = 0.006), and BMI before treatment (underweight: β = -59.93, P = 0.05; overweight: β = -40.62, P = 0.041). Location of transposed ovaries, adjuvant CCRT, and BMI before treatment may be associated with ovarian function after treatment. We suggest that ovaries should be transposed as highly as possible during radical hysterectomy to preserve ovarian function in young patients with early cervical cancer who might be a candidate for adjuvant CCRT and who have low BMI before treatment.

  18. Clinical outcomes for 14 consecutive patients with solid pseudopapillary neoplasms who underwent laparoscopic distal pancreatectomy.

    Science.gov (United States)

    Nakamura, Yoshiharu; Matsushita, Akira; Katsuno, Akira; Yamahatsu, Kazuya; Sumiyoshi, Hiroki; Mizuguchi, Yoshiaki; Uchida, Eiji

    2016-02-01

    The postoperative results of laparoscopic distal pancreatectomy for solid pseudopapillary neoplasm of the pancreas (SPN), including the effects of spleen-preserving resection, are still to be elucidated. Of the 139 patients who underwent laparoscopic pancreatectomy for non-cancerous tumors, 14 consecutive patients (average age, 29.6 years; 1 man, 13 women) with solitary SPN who underwent laparoscopic distal pancreatectomy between March 2004 and June 2015 were enrolled. The tumors had a mean diameter of 4.8 cm. Laparoscopic spleen-preserving distal pancreatectomy was performed in eight patients (spleen-preserving group), including two cases involving pancreatic tail preservation, and laparoscopic spleno-distal pancreatectomy was performed in six patients (standard resection group). The median operating time was 317 min, and the median blood loss was 50 mL. Postoperatively, grade B pancreatic fistulas appeared in two patients (14.3%) but resolved with conservative treatment. No patients had postoperative complications, other than pancreatic fistulas, or required reoperation. The median postoperative hospital stay was 11 days, and the postoperative mortality was zero.None of the patients had positive surgical margins or lymph nodes with metastasis. The median follow-up period did not significantly differ between the two groups (20 vs 39 months, P = 0.1368). All of the patients are alive and free from recurrent tumors without major late-phase complications. Laparoscopic distal pancreatectomy might be a suitable treatment for patients with SPN. A spleen-preserving operation is preferable for younger patients with SPN, and this study demonstrated the non-inferiority of the procedure compared to spleno-distal pancreatectomy. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  19. Beneficial Effect of the Nutritional Support in Children Who Underwent Hematopoietic Stem Cell Transplant.

    Science.gov (United States)

    Koç, Nevra; Gündüz, Mehmet; Tavil, Betül; Azik, M Fatih; Coşkun, Zeynep; Yardımcı, Hülya; Uçkan, Duygu; Tunç, Bahattin

    2017-08-01

    The aim of this study was to evaluate nutritional status in children who underwent hematopoietic stem cell transplant compared with a healthy control group. A secondary aim was to utilize mid-upper arm circumference as a measure of nutritional status in these groups of children. Our study group included 40 children (18 girls, 22 boys) with mean age of 9.2 ± 4.6 years (range, 2-17 y) who underwent hematopoietic stem cell transplant. Our control group consisted of 20 healthy children (9 girls, 11 boys). The children were evaluated at admission to the hospital and followed regularly 3, 6, 9, and 12 months after discharge from the hospital. In the study group, 27 of 40 patients (67.5%) received nutritional support during hematopoietic stem cell transplant, with 15 patients (56%) receiving enteral nutrition, 6 (22%) receiving total parenteral nutrition, and 6 (22%) receiving enteral and total parenteral nutrition. Chronic malnutrition rate in the study group was 47.5% on admission to the hospital, with the control group having a rate of 20%. One year after transplant, the rate decreased to 20% in the study group and 5% in the control group. The mid-upper arm circumference was lower in children in the study group versus the control group at the beginning of the study (P groups at follow-up examinations (P > .05). During follow-up, all anthropometric measurements increased significantly in both groups. Monitoring nutritional status and initiating appropriate nutritional support improved the success of hematopoietic stem cell transplant and provided a more comfortable process during the transplant period. Furthermore, mid-upper arm circumference is a more sensitive, useful, and safer parameter that can be used to measure nutritional status of children who undergo hematopoietic stem cell transplant.

  20. The physics of compensating calorimetry and the new CALOR89 code system

    International Nuclear Information System (INIS)

    Gabriel, T.A.; Brau, J.E.; Bishop, B.L.

    1989-03-01

    Much of the understanding of the physics of calorimetry has come from the use of excellent radiation transport codes. A new understanding of compensating calorimetry was introduced four years ago following detailed studies with a new CALOR system. Now, the CALOR system has again been revised to reflect a better comprehension of high energy nuclear collisions by incorporating a modified high energy fragmentation model from FLUKA87. This revision will allow for the accurate analysis of calorimeters at energies of 100's of GeV. Presented in this paper is a discussion of compensating calorimetry, the new CALOR system, the revisions to HETC, and recently generated calorimeter related data on modes of energy deposition and secondary neutron production (E < 50 MeV) in infinite iron and uranium blocks. 38 refs., 5 figs., 5 tabs

  1. Application of prediction of equilibrium to servo-controlled calorimetry measurements

    International Nuclear Information System (INIS)

    Mayer, R.L. II.

    1987-01-01

    Research was performed to develop an endpoint prediction algorithm for use with calorimeters operating in the digital servo-controlled mode. The purpose of this work was to reduce calorimetry measurement times while maintaining the high degree of precision and low bias expected from calorimetry measurements. Data from routine operation of two calorimeters were used to test predictive models at each stage of development against time savings, precision, and robustness criteria. The results of the study indicated that calorimetry measurement times can be significantly reduced using this technique. The time savings is, however, dependent on parameters in the digital servo-control algorithm and on packaging characteristics of measured items. 7 refs., 4 figs., 1 tab

  2. Study of interactions between hyaluronan and cationic surfactants by means of calorimetry, turbidimetry, potentiometry and conductometry.

    Science.gov (United States)

    Krouská, J; Pekař, M; Klučáková, M; Šarac, B; Bešter-Rogač, M

    2017-02-10

    The thermodynamics of the micelle formation of the cationic surfactants tetradecyltrimethylammonium bromide (TTAB) and cetyltrimethylammonium bromide (CTAB) with and without the addition of hyaluronan of two molecular weights was studied in aqueous solution by titration calorimetry. Macroscopic phase separation, which was detected by calorimetry and also by conductometry, occurs when charges on the surfactant and hyaluronan are balanced. In contrast, turbidimetry and potentiometry showed hyaluronan-surfactant interactions at very low surfactant concentrations. The observed differences between systems prepared with CTAB and TTAB indicate that besides the electrostatic interactions, which probably predominate, hydrophobic effects also play a significant role in hyaluronan interactions with cationic surfactants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Optical fibre temperature sensor technology and potential application in absorbed dose calorimetry

    International Nuclear Information System (INIS)

    Allen, P.D.; Hargrave, N.J.

    1992-09-01

    Optical fibre based sensors are proposed as a potential alternative to the thermistors traditionally used as temperature sensors in absorbed dose calorimetry. The development of optical fibre temperature sensor technology over the last ten years is reviewed. The potential resolution of various optical techniques is assessed with particular reference to the requirements of absorbed dose calorimetry. Attention is drawn to other issues which would require investigation before the development of practical optical fibre sensors for this purpose could occur. 192 refs., 5 tabs., 4 figs

  4. Thermodynamics of Surfactants, Block Copolymers and Their Mixtures in Water: The Role of the Isothermal Calorimetry

    Science.gov (United States)

    De Lisi, Rosario; Milioto, Stefania; Muratore, Nicola

    2009-01-01

    The thermodynamics of conventional surfactants, block copolymers and their mixtures in water was described to the light of the enthalpy function. The two methodologies, i.e. the van’t Hoff approach and the isothermal calorimetry, used to determine the enthalpy of micellization of pure surfactants and block copolymers were described. The van’t Hoff method was critically discussed. The aqueous copolymer+surfactant mixtures were analyzed by means of the isothermal titration calorimetry and the enthalpy of transfer of the copolymer from the water to the aqueous surfactant solutions. Thermodynamic models were presented to show the procedure to extract straightforward molecular insights from the bulk properties. PMID:19742173

  5. Study of the seroma volume changes in the patients who underwent Accelerated Partial Breast Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Son, Sang Jun; Mun, Jun Ki; Seo, Seok Jin; Lee, Je Hee [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2016-06-15

    By analyzing seroma volume changes in the patients who underwent Partial breast radiation therapy after breast conserving surgery, we try to contribute to the improvement of radiotherapy effect. Enrolled 20 patients who underwent partial breast radiation therapy by ViewRay MRIdian System were subject. After seeking for the size of the removed sample in the patients during surgery and obtained seroma volume changes on a weekly basis. On the Basis of acquired volume, it was compared with age, term from start of the first treatment after surgery, BMI (body mass index) and the extracted sample size during surgery. And using the ViewRay MRIdian RTP System, the figure was analyzed by PTV(=seroma volume + margin) to obtain a specific volume of the Partial breast radiation therapy. The changes of seroma volume from MR simulation to the first treatment (a week) is 0~5% in 8, 5~10% in 3, 10 to 15% in 2, and 20% or more in 5 people. Two patients(A, B patient) among subjects showed the biggest change. The A patient's 100% of the prescribed dose volume is 213.08 cc, PTV is 181.93 cc, seroma volume is 15.3 cc in initial plan. However, while seroma volume decreased 65.36% to 5.3 cc, 100% of the prescribed dose volume was reduced to 3.4% to 102.43 cc and PTV also did 43.6% to 102.54 cc. In the case of the B patient, seroma volume decreased 42.57% from 20.2 cc to 11.6 cc. Because of that, 100% of the prescribed dose volume decreased 8.1% and PTV also did to 40%. As the period between the first therapy and surgery is shorter, the patient is elder and the size of sample is smaller than 100 cc, the change grow bigger. It is desirable to establish an adaptive plan according to each patient's changes of seroma volume through continuous observation. Because partial breast patients is more sensitive than WBRT patients about dose conformity in accordance with the volume change.

  6. Dysphagia among adult patients who underwent surgery for esophageal atresia at birth.

    Science.gov (United States)

    Huynh Trudeau, Valérie; Maynard, Stéphanie; Terzic, Tatjana; Soucy, Geneviève; Bouin, Mickeal

    2015-03-01

    Clinical experiences of adults who underwent surgery for esophageal atresia at birth is limited. There is some evidence that suggests considerable long-term morbidity, partly because of dysphagia, which has been reported in up to 85% of adult patients who undergo surgery for esophageal atresia. The authors hypothesized that dysphagia in this population is caused by dysmotility and⁄or anatomical anomalies. To determine the motor and anatomical causes of dysphagia. A total of 41 adults, followed at the Esophageal Atresia Clinic at Hôpital Saint-Luc (Montreal, Quebec), were approached to particpate in the present prospective study. Evaluation was completed using upper endoscopy, manometry and barium swallow for the participants who consented. The medical charts of respondents were systematically reviewed from the neonatal period to 18 years of age to assess medical and surgical history. All 41 patients followed at the clinic consented and were included in the study. Dysphagia was present in 73% of patients. Esophagogastroduodenoscopy was performed in 32 patients: hiatal hernia was present in 62% (n=20); esophageal diverticulum in 13% (n=4); macroscopic Barrett esophagus in 31% (n=10); and esophagitis in 19% (n=6). Histological esophagitis was present in 20% and intestinal metaplasia in 10%. There were no cases of dysplagia or adenocarcinoma. Esophageal manometry was performed on 56% of the patients (n=23). Manometry revealed hypomotility in 100% of patients and included an insufficient number of peristaltic waves in 96%, nonpropagating peristalsis in 78% and low-wave amplitude in 95%. Complete aperistalsis was present in 78%. The lower esophageal sphincter was abnormal in 12 (52%) patients, with incomplete relaxation the most common anomaly. Of the 41 patients, 29 (71%) consented to a barium swallow, which was abnormal in 13 (45%). The anomalies found were short esophageal dilation in 28%, delay in esophageal emptying in 14%, diverticula in 14% and stenosis in 7

  7. Study of the seroma volume changes in the patients who underwent Accelerated Partial Breast Irradiation

    International Nuclear Information System (INIS)

    Kim, Dae Ho; Son, Sang Jun; Mun, Jun Ki; Seo, Seok Jin; Lee, Je Hee

    2016-01-01

    By analyzing seroma volume changes in the patients who underwent Partial breast radiation therapy after breast conserving surgery, we try to contribute to the improvement of radiotherapy effect. Enrolled 20 patients who underwent partial breast radiation therapy by ViewRay MRIdian System were subject. After seeking for the size of the removed sample in the patients during surgery and obtained seroma volume changes on a weekly basis. On the Basis of acquired volume, it was compared with age, term from start of the first treatment after surgery, BMI (body mass index) and the extracted sample size during surgery. And using the ViewRay MRIdian RTP System, the figure was analyzed by PTV(=seroma volume + margin) to obtain a specific volume of the Partial breast radiation therapy. The changes of seroma volume from MR simulation to the first treatment (a week) is 0~5% in 8, 5~10% in 3, 10 to 15% in 2, and 20% or more in 5 people. Two patients(A, B patient) among subjects showed the biggest change. The A patient's 100% of the prescribed dose volume is 213.08 cc, PTV is 181.93 cc, seroma volume is 15.3 cc in initial plan. However, while seroma volume decreased 65.36% to 5.3 cc, 100% of the prescribed dose volume was reduced to 3.4% to 102.43 cc and PTV also did 43.6% to 102.54 cc. In the case of the B patient, seroma volume decreased 42.57% from 20.2 cc to 11.6 cc. Because of that, 100% of the prescribed dose volume decreased 8.1% and PTV also did to 40%. As the period between the first therapy and surgery is shorter, the patient is elder and the size of sample is smaller than 100 cc, the change grow bigger. It is desirable to establish an adaptive plan according to each patient's changes of seroma volume through continuous observation. Because partial breast patients is more sensitive than WBRT patients about dose conformity in accordance with the volume change

  8. Comparative analysis of pain in patients who underwent total knee replacement regarding the tourniquet pressure

    Directory of Open Access Journals (Sweden)

    Marcos George de Souza Leão

    Full Text Available ABSTRACT OBJECTIVES: To evaluate through the visual analog scale (VAS the pain in patients undergoing total knee replacement (TKR with different pressures of the pneumatic tourniquet. METHODS: An observational, randomized, descriptive study on an analytical basis, with 60 patients who underwent TKR, divided into two groups, which were matched: a group where TKR was performed with tourniquet pressures of 350 mmHg (standard and the other with systolic blood pressure plus 100 mmHg (P + 100. These patients had their pain assessed by VAS at 48 h, and at the 5th and 15th days after procedure. Secondarily, the following were also measured: range of motion (ROM, complications, and blood drainage volume in each group; the data were subjected to statistical analysis. RESULTS: After data analysis, there was no statistical difference regarding the incidence of complications (p = 0.612, ROM (p = 0.202, bleeding after 24 and 48 h (p = 0.432 and p = 0.254 or in relation to VAS. No correlation was observed between time of ischemia compared to VAS and bleeding. CONCLUSIONS: The use of the pneumatic tourniquet pressure at 350 mmHg or systolic blood pressure plus 100 mmHg did not influence the pain, blood loss, ROM, and complications. Therefore the pressures at these levels are safe and do not change the surgery outcomes; the time of ischemia must be closely observed to avoid major complications.

  9. Association of PTP1B with Outcomes of Breast Cancer Patients Who Underwent Neoadjuvant Chemotherapy.

    Science.gov (United States)

    Rivera Franco, Monica M; Leon Rodriguez, Eucario; Martinez Benitez, Braulio; Villanueva Rodriguez, Luisa G; de la Luz Sevilla Gonzalez, Maria; Armengol Alonso, Alejandra

    2016-01-01

    PTP1B is involved in the oncogenesis of breast cancer. In addition, neoadjuvant therapy has been widely used in breast cancer; thus, a measurement to assess survival improvement could be pathological complete response (pCR). Our objective was to associate PTP1B overexpression with outcomes of breast cancer patients who underwent neoadjuvant chemotherapy. Forty-six specimens were included. Diagnostic biopsies were immunostained using anti-PTP1B antibody. Expression was categorized as negative (<5%) and overexpression (≥5%). Patients' responses were graded according to the Miller-Payne system. Sixty-three percent of patients overexpressed PTP1B. There was no significant association between PTP1B overexpression and pCR ( P = 0.2). However, when associated with intrinsic subtypes, overexpression was higher in human epidermal growth factor receptor 2-positive-enriched specimens ( P = 0.02). Ten-year progression-free survival showed no differences. Our preliminary results do not show an association between PTP1B over-expression and pCR; however, given the limited sample and heterogeneous treatment in our cohort, this hypothesis cannot be excluded.

  10. Association of PTP1B with Outcomes of Breast Cancer Patients who Underwent Neoadjuvant Chemotherapy

    Directory of Open Access Journals (Sweden)

    Monica M. Rivera Franco

    2016-01-01

    Full Text Available PTP1B is involved in the oncogenesis of breast cancer. In addition, neoadjuvant therapy has been widely used in breast cancer; thus, a measurement to assess survival improvement could be pathological complete response (pCR. Our objective was to associate PTP1B overexpression with outcomes of breast cancer patients who underwent neoadjuvant chemotherapy. Forty-six specimens were included. Diagnostic biopsies were immunostained using anti-PTP1B antibody. Expression was categorized as negative (<5% and overexpression (≥5%. Patients' responses were graded according to the Miller-Payne system. Sixty-three percent of patients overexpressed PTP1B. There was no significant association between PTP1B overexpression and pCR (P = 0.2. However, when associated with intrinsic subtypes, overexpression was higher in human epidermal growth factor receptor 2-positive-enriched specimens (P = 0.02. Ten-year progression-free survival showed no differences. Our preliminary results do not show an association between PTP1B overexpression and pCR; however, given the limited sample and heterogeneous treatment in our cohort, this hypothesis cannot be excluded.

  11. [A survey of perioperative asthmatic attack among patients with bronchial asthma underwent general anesthesia].

    Science.gov (United States)

    Ie, Kenya; Yoshizawa, Atsuto; Hirano, Satoru; Izumi, Sinyuu; Hojo, Masaaki; Sugiyama, Haruhito; Kobayasi, Nobuyuki; Kudou, Kouichirou; Maehara, Yasuhiro; Kawachi, Masaharu; Miyakoshi, Kouichi

    2010-07-01

    We investigated the risk factor of perioperative asthmatic attack and effectiveness of preventing treatment for asthmatic attack before operation. We performed retrospective chart review of one hundred eleven patients with asthma underwent general anesthesia and surgical intervention from January 2006 to October 2007 in our hospital. The rate of perioperative asthmatic attack were as follows; 10.2% (5 in 49 cases) in no pretreatment group, 7.5% (3 in 40 cases) in any pretreatments except for systemic steroid, and 4.5% (1 in 22 cases) in systemic steroid pretreatment group. Neither preoperative asthma severity nor duration from the last attack had significant relevancy to perioperative attack rate. The otolaryngological surgery, especially those have nasal polyp and oral surgery had high perioperative asthma attack rate, although there was no significant difference. We recommend the systemic steroid pretreatment for asthmatic patients, especially when they have known risk factor such as administration of the systemic steroid within 6 months, or possibly new risk factor such as nasal polyp, otolaryngological and oral surgery.

  12. Stress and Quality of Life for Taiwanese Women Who Underwent Infertility Treatment.

    Science.gov (United States)

    Cheng, Ching-Yu; Stevenson, Eleanor Lowndes; Yang, Cheng-Ta; Liou, Shwu-Ru

    2018-04-28

    To describe the psychological stress and quality of life experienced by women who underwent fertility treatment in Taiwan. Cross-sectional, correlational study. Recruitment was conducted and questionnaires administered at a reproductive medicine center in Chiayi City, Taiwan. Informed consent to participate was obtained from 126 women who sought fertility treatment at the center. The Chinese Fertility Problem Inventory and Fertility Quality of Life scale were used to measure participants' levels of fertility-related stress and fertility-related quality of life. Descriptive statistics, correlation, and regression analysis were used. Overall, participants reported low levels of fertility-related stress and fertility-related quality of life; however, they had relatively high levels of stress related to need for parenthood. Women who were older, had greater body mass indexes, and consumed coffee regularly had lower fertility-related quality of life. Social and relationship concerns and stress related to need for parenthood were significant predictors of low fertility-related quality of life. In a culture in which childbearing is generally an expectation and an important part of family life, women who experience infertility are at risk to experience fertility-related stress. Social support and family consultation might be offered to improve women's fertility-related quality of life. Copyright © 2018 AWHONN, the Association of Women’s Health, Obstetric and Neonatal Nurses. Published by Elsevier Inc. All rights reserved.

  13. Characterization of thermophysical properties of phase change materials for non-membrane based indirect solar desalination application

    International Nuclear Information System (INIS)

    Sarwar, J.; Mansoor, B.

    2016-01-01

    Highlights: • Thermal cycling of paraffin waxes phase change materials. • Differential Scanning Calorimetry and thermogravimetric study of the materials. • Characterization of the phase change materials via Temperature History Method. • Investigation of suitability of materials for indirect solar desalination system. • Paraffin waxes are suitable for non-membrane indirect solar desalination system. - Abstract: Phase change material as a thermal energy storage medium has been widely incorporated in various technologies like solar air/water heating, buildings, and desalination for efficient use and management of fluctuating solar energy. Temperature and thermal energy requirements dictate the selection of an appropriate phase change material for its application in various engineering systems. In this work, two phase change materials belonging to organic paraffin wax class have been characterized to obtain their thermophysical properties. The melting/solidification temperatures, latent heat of fusion and heat capacities of the phase change materials have been investigated using Differential Scanning Calorimetry, Thermogravimetric analysis and Temperature History Method. Thermal cycles up to 300 are performed to investigate melting and solidification reversibility as well as degradation over time. It is shown that the selected paraffin waxes have reversible phase change with no degradation of thermophysical properties over time. It is also shown that melting/solidification temperature and thermal energy storage capabilities make them suitable for their application as a thermal energy storage medium, in high temperature vapour compression, multi-stage flash and multi-effect distillation processes of non-membrane based indirect desalination systems.

  14. Aqueous solutions of proline and NaCl studied by differential scanning calorimetry at subzero temperatures

    DEFF Research Database (Denmark)

    Rasmussen, Peter Have; Jørgensen, Bo; Nielsen, Jette

    1997-01-01

    The hydration properties of proline are studied by differential scanning calorimetry (DSC) in aqueous solutions during freezing to -60 degrees C and subsequent heating to +20 degrees C. The concentration of proline in the freeze concentrated solution was estimated to approximately 50 wt% (w/w) in...... plants and insects living under water stress conditions is discussed. (C) 1997 Elsevier Science B.V....

  15. Isothermal Titration Calorimetry and Macromolecular Visualization for the Interaction of Lysozyme and Its Inhibitors

    Science.gov (United States)

    Wei, Chin-Chuan; Jensen, Drake; Boyle, Tiffany; O'Brien, Leah C.; De Meo, Cristina; Shabestary, Nahid; Eder, Douglas J.

    2015-01-01

    To provide a research-like experience to upper-division undergraduate students in a biochemistry teaching laboratory, isothermal titration calorimetry (ITC) is employed to determine the binding constants of lysozyme and its inhibitors, N-acetyl glucosamine trimer (NAG[subscript 3]) and monomer (NAG). The extremely weak binding of lysozyme/NAG is…

  16. Subsite binding energies of an exo-polygalacturonase using isothermal titration calorimetry

    Science.gov (United States)

    Thermodynamic parameters for binding of a series of galacturonic acid oligomers to an exo-polygalacturonase, RPG16 from Rhizopus oryzae, were determined by isothermal titration calorimetry. Binding of oligomers varying in chain length from two to five galacturonic acid residues is an exothermic proc...

  17. Thermodynamic investigations of protein's behaviour with ionic liquids in aqueous medium studied by isothermal titration calorimetry.

    Science.gov (United States)

    Bharmoria, Pankaj; Kumar, Arvind

    2016-05-01

    While a number of reports appear on ionic liquids-proteins interactions, their thermodynamic behaviour using suitable technique like isothermal titration calorimetry is not systematically presented. Isothermal titration calorimetry (ITC) is a key technique which can directly measure the thermodynamic contribution of IL binding to protein, particularly the enthalpy, heat capacities and binding stoichiometry. Ionic liquids (ILs), owing to their unique and tunable physicochemical properties have been the central area of scientific research besides graphene in the last decade, and growing unabated. Their encounter with proteins in the biological system is inevitable considering their environmental discharge though most of them are recyclable for a number of cycles. In this article we will cover the thermodynamics of proteins upon interaction with ILs as osmolyte and surfactant. The up to date literature survey of IL-protein interactions using isothermal titration calorimetry will be discussed and parallel comparison with the results obtained for such studies with other techniques will be highlighted to demonstrate the accuracy of ITC technique. Net stability of proteins can be obtained from the difference in the free energy (ΔG) of the native (folded) and denatured (unfolded) state using the Gibbs-Helmholtz equation (ΔG=ΔH-TΔS). Isothermal titration calorimetry can directly measure the heat changes upon IL-protein interactions. Calculation of other thermodynamic parameters such as entropy, binding constant and free energy depends upon the proper fitting of the binding isotherms using various fitting models. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Monolithic front-end preamplifiers for a broad range of calorimetry applications

    Energy Technology Data Exchange (ETDEWEB)

    Radeka, V.; Rescia, S. [Brookhaven National Lab., Upton, NY (United States); Manfredi, P.F.; Speziali, V. [Pavia Univ. (Italy). Dipt. di Elettronica]|[INFN--Sezzione di Milano, Milano (Italy)

    1993-12-31

    The present paper summarizes the salient results of a research and development activity in the area of low noise preamplifiers for different applications in calorimetry. Design target for all circuits considered here are low noise, ability to cope with broad energy ranges and radiation hardness.

  19. Proton and Copper Binding to Humic Acids Analyzed by XAFS Spectroscopy and Isothermal Titration Calorimetry

    NARCIS (Netherlands)

    Xu, Jinling; Koopal, Luuk K.; Fang, Linchuan; Xiong, Juan; Tan, Wenfeng

    2018-01-01

    Proton and copper (Cu) binding to soil and lignite-based humic acid (HA) was investigated by combining X-ray absorption fine structure (XAFS) spectroscopy, isothermal titration calorimetry (ITC), and nonideal-competitive-adsorption (NICA) modeling. NICA model calculations and XAFS results showed

  20. Study of phase transition in hard microcrystalline waxes and wax blends by differential scanning calorimetry

    Czech Academy of Sciences Publication Activity Database

    Kumar, S.; Agrawal, K. M.; Khan, H. U.; Sikora, Antonín

    2004-01-01

    Roč. 22, 3 & 4 (2004), s. 337-345 ISSN 1091-6466 R&D Projects: GA AV ČR KSK4050111 Institutional research plan: CEZ:AV0Z4050913 Keywords : phase transition * hard microscrystalline waxes * differential scanning calorimetry Subject RIV: CD - Macromolecular Chemistry Impact factor: 0.312, year: 2004

  1. Monolithic junction field-effect transistor charge preamplifier for calorimetry at high luminosity hadron colliders

    International Nuclear Information System (INIS)

    Radeka, V.; Rescia, S.; Rehn, L.A.; Manfredi, P.F.; Speziali, V.

    1991-11-01

    The outstanding noise and radiation hardness characteristics of epitaxial-channel junction field-effect transistors (JFET) suggest that a monolithic preamplifier based upon them may be able to meet the strict specifications for calorimetry at high luminosity colliders. Results obtained so far with a buried layer planar technology, among them an entire monolithic charge-sensitive preamplifier, are described

  2. Detection of sunflower oil in extra virgin olive oil by fast differential scanning calorimetry

    NARCIS (Netherlands)

    Wetten, I.A.; Herwaarden, A.W.; Splinter, R.; Boerrigter-Eenling, R.; Ruth, van S.M.

    2015-01-01

    Extra virgin olive oil (EVOO) is an economically valuable product, due to its high quality and premium price. Therefore it is vulnerable for adulteration by means of the addition of cheaper vegetable oils. Differential scanning calorimetry (DSC) has been suggested as a fast technique for the

  3. Impact of sample saturation on the detected porosity of hardened concrete using low temperature calorimetry

    DEFF Research Database (Denmark)

    Wu, Min; Johannesson, Björn

    2014-01-01

    The present work studied the impact of sample saturation on the analysis of pore volume and pore size distribution by low temperature (micro-)calorimetry. The theoretical background was examined, which emphasizes that the freezing/melting temperature of water/ice confined in non-fully saturated p...

  4. Designing a compensating quartz fiber calorimeter for low angle calorimetry at LHC

    International Nuclear Information System (INIS)

    Ferrando, A.; Fouz, M.C.; Josa, M.I.; Khan, A.; Rosowsky, A.; Salicio, J.M.

    1996-01-01

    We present a design of a compensating quartz fiber calorimeter, made of a unique active section, and ment for the specific physics requirements of the low angle calorimetry in LHC experiments. The purposed calorimeter is exemplified for the case of the CMS experiment

  5. Coulometry and Calorimetry of Electric Double Layer Formation in Porous Electrodes

    NARCIS (Netherlands)

    Janssen, Mathijs; Griffioen, Elian; Biesheuvel, P. M.; Van Roij, René; Erné, Ben

    2017-01-01

    Coulometric measurements on salt-water-immersed nanoporous carbon electrodes reveal, at a fixed voltage, a charge decrease with increasing temperature. During far-out-of-equilibrium charging of these electrodes, calorimetry indicates the production of both irreversible Joule heat and reversible

  6. Thermodynamic profiling of Peptide membrane interactions by isothermal titration calorimetry: a search for pores and micelles

    DEFF Research Database (Denmark)

    Henriksen, Jonas Rosager; Andresen, Thomas Lars

    2011-01-01

    in mixed peptide-lipid micelles. We have investigated the mode of action of the antimicrobial peptide mastoparan-X using isothermal titration calorimetry (ITC) and cryo-transmission electron microscopy (cryo-TEM). The results show that mastoparan-X induces a range of structural transitions of POPC/POPG (3...

  7. Examination of water phase transitions in Loblolly pine and cell wall components by differential scanning calorimetry

    Science.gov (United States)

    Samuel L. Zelinka; Michael J. Lambrecht; Samuel V. Glass; Alex C. Wiedenhoeft; Daniel J. Yelle

    2012-01-01

    This paper examines phase transformations of water in wood and isolated wood cell wall components using differential scanning calorimetry with the purpose of better understanding "Type II water" or "freezable bound water" that has been reported for cellulose and other hydrophilic polymers. Solid loblolly pine (Pinus taeda...

  8. High Pressure Differential Scanning Calorimetry of poly(4-methyl-pentene-1)

    NARCIS (Netherlands)

    Hoehne, G.W.H.; Rastogi, S.; Wunderlich, B.

    2000-01-01

    The polymer poly(4-methyl pentene-1), P4MP1, displays an unusual pressure–temperature phase diagram. The previous exploration of this phase behavior through X-ray diffraction has been extended through high-pressure calorimetry. The resulting phase diagram displays a melt area, the common tetragonal

  9. Association between ambient air pollution and pregnancy rate in women who underwent IVF.

    Science.gov (United States)

    Choe, S A; Jun, Y B; Lee, W S; Yoon, T K; Kim, S Y

    2018-04-05

    Are the concentrations of five criteria air pollutants associated with probabilities of biochemical pregnancy loss and intrauterine pregnancy in women? Increased concentrations of ambient particulate matter (PM10), nitrogen dioxide (NO2), carbon monoxide (CO) during controlled ovarian stimulation (COS) and after embryo transfer were associated with a decreased probability of intrauterine pregnancy. Exposure to high ambient air pollution was suggested to be associated with low fertility and high early pregnancy loss in women. Using a retrospective cohort study design, we analysed 6621 cycles of 4581 patients who underwent one or more fresh IVF cycles at a fertility centre from January 2006 to December 2014, and lived in Seoul at the time of IVF treatment. To estimate patients' individual exposure to air pollution, we computed averages of hourly concentrations of five air pollutants including PM10, NO2, CO, sulphur dioxide (SO2) and ozone (O3) measured at 40 regulatory monitoring sites in Seoul for each of the four exposure periods: period 1 (start of COS to oocyte retrieval), period 2 (oocyte retrieval to embryo transfer), period 3 (embryo transfer to hCG test), and period 4 (start of COS to hCG test). Hazard ratios (HRs) from the time-varying Cox-proportional hazards model were used to estimate probabilities of biochemical pregnancy loss and intrauterine pregnancy for an interquartile range (IQR) increase in each air pollutant concentration during each period, after adjusting for individual characteristics. We tested the robustness of the result using generalised linear mixed model, accounting for within-woman correlation. Mean age of the women was 35 years. Average BMI was 20.9 kg/m2 and the study population underwent 1.4 IVF cycles on average. Cumulative pregnancy rate in multiple IVF cycles was 51.3% per person. Survival analysis showed that air pollution during periods 1 and 3 was generally associated with IVF outcomes. Increased NO2 (adjusted HR = 0.93, 95% CI

  10. Predictors of weight regain in patients who underwent Roux-en-Y gastric bypass surgery.

    Science.gov (United States)

    Shantavasinkul, Prapimporn Chattranukulchai; Omotosho, Philip; Corsino, Leonor; Portenier, Dana; Torquati, Alfonso

    2016-11-01

    Roux-en-Y gastric bypass (RYGB) is a highly effective treatment for obesity and results in long-term weight loss and resolution of co-morbidities. However, weight regain may occur as soon as 1-2 years after surgery. This retrospective study aimed to investigate the prevalence of weight regain and possible preoperative predictors of this phenomenon after RYGB. An academic medical center in the United States. A total of 1426 obese patients (15.8% male) who underwent RYGB during January 2000 to 2012 and had at least a 2-year follow-up were reviewed. We included only patients who were initially successful, having achieved at least 50% excess weight loss at 1 year postoperatively. Patients were then categorized into either the weight regain group (WR) or sustained weight loss (SWL) group based upon whether they gained≥15% of their 1-year postoperative weight. Weight regain was observed in 244 patients (17.1%). Preoperative body mass index was similar between groups. Body mass index was significantly higher and percent excess weight loss was significantly lower in the WR group (Pweight regain was 19.5±9.3 kg and-.8±8.5 in the WR and SWL groups, respectively (Pweight loss. Moreover, a longer duration after RYGB was associated with weight regain. Multivariate analysis revealed that younger age was a significant predictor of weight regain even after adjusting for time since RYGB. The present study confirmed that a longer interval after RYGB was associated with weight regain. Younger age was a significant predictor of weight regain even after adjusting for time since RYGB. The findings of this study underscore the complexity of the mechanisms underlying weight loss and regain after RYGB. Future prospective studies are needed to further explore the prevalence, predictors, and mechanisms of weight regain after RYGB. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  11. Indirect Self-Destructiveness and Emotional Intelligence.

    Science.gov (United States)

    Tsirigotis, Konstantinos

    2016-06-01

    While emotional intelligence may have a favourable influence on the life and psychological and social functioning of the individual, indirect self-destructiveness exerts a rather negative influence. The aim of this study has been to explore possible relations between indirect self-destructiveness and emotional intelligence. A population of 260 individuals (130 females and 130 males) aged 20-30 (mean age of 24.5) was studied by using the Polish version of the chronic self-destructiveness scale and INTE, i.e., the Polish version of the assessing emotions scale. Indirect self-destructiveness has significant correlations with all variables of INTE (overall score, factor I, factor II), and these correlations are negative. The intensity of indirect self-destructiveness differentiates significantly the height of the emotional intelligence and vice versa: the height of the emotional intelligence differentiates significantly the intensity of indirect self-destructiveness. Indirect self-destructiveness has negative correlations with emotional intelligence as well as its components: the ability to recognize emotions and the ability to utilize emotions. The height of emotional intelligence differentiates the intensity of indirect self-destructiveness, and vice versa: the intensity of indirect self-destructiveness differentiates the height of emotional intelligence. It seems advisable to use emotional intelligence in the prophylactic and therapeutic work with persons with various types of disorders, especially with the syndrome of indirect self-destructiveness.

  12. Chemical kinetics on thermal decompositions of cumene hydroperoxide in cumene studied by calorimetry: An overview

    Energy Technology Data Exchange (ETDEWEB)

    Duh, Yih-Shing, E-mail: yihshingduh@yahoo.com.tw [Department of Occupation Safety and Health, Jen-Teh Junior College of Medicine, Nursing and Management, Miaoli, 35664, Taiwan, ROC (China); Department of Safety, Health and Environmental Engineering, National United University, No. 1 Lien-Da, Miaoli, 36052, Taiwan, ROC (China)

    2016-08-10

    Highlights: • Chemical kinetics on thermal decompositions of CHP are conducted and summarized. • Kinetics agrees well between data from DSC and adiabatic calorimetry. • Ea is determined to be about 120 kJ mol{sup −1} by various calorimetry. • LogA (A in s{sup −1}) is determined to be about 11.8 by various calorimetry. - Abstract: Study on chemical kinetics related to the thermal decomposition of cumene hydoperoxide (CHP) in cumene is summarized in this work. It is of great importance to gather and compare the differences between these kinetic parameters for further substantial applications in the chemical industry and process safety. CHP has been verified to possess an autocatalytic behavior by using microcalorimetry (such as TAM and C-80) operated at isothermal mode in the temperature range from 70 °C to 120 °C. However, it exhibits a reaction of n-th order detected by non-isothermal DSC scanning and adiabatic calorimeter. By the isothermal aging tests, activation energy and frequency factor in logA(s{sup −1}) were averaged to be (117.3 ± 5.9) kJ mol{sup −1}and (11.4 ± 0.3), respectively. Kinetic parameters acquired from data of interlaboratories by using heat-flow calorimetry, the averaged activation energy and frequency factor in logA(s{sup −1}) were (119.3 ± 11.3) kJ mol{sup −1}and (12.0 ± 0.2), respectively. On the analogy of results from adiabatic calorimetry, the activation energy and frequency factor in logA(s{sup −1}) were respectively averaged to be (122.4 ± 9.2) kJ mol{sup −1}and (11.8 ± 0.8). Five sets of kinetic models in relation to autocatalytic reactions are collected and discussed as well.

  13. Quality of life in locally advanced prostate cancer patients who underwent hormonal treatment combined with radiotherapy

    International Nuclear Information System (INIS)

    Koga, Hirofumi; Naito, Seiji; Fukui, Iwao; Tsukamoto, Taiji; Matsuoka, Naoki; Fujimoto, Hiroyuki

    2004-01-01

    The aim of this study is to estimate the feasibility of quality of life (QOL) research and to evaluate the QOL prospectively in locally advanced prostate cancer patients treated with hormonal treatment combined with radiotherapy. The treatment schedule was that patients with decreasing prostatic specific antigen (PSA) levels below 10 ng/ml after receiving 6 months of neoadjuvant hormonal treatment were randomly divided into two groups; one group was the continuous hormonal treatment group and the other was the intermittent hormonal treatment group. Both groups received a total dose of 72 Gy external beam radiotherapy with concomitant hormonal treatment followed by 6 months of adjuvant hormonal treatment following radiotherapy. At 14 months, patients either underwent continuous or intermittent hormonal treatment according to the random allocation. QOL was assessed at baseline, and at 6, 8, 14, and 20 months after treatment using functional assessment of cancer treatment-general (FACT-G), P with the other 3 items comprising bother of urination, bother of bowel movement, and bother of sexual activity. Between January 2000 and June 2003, a total of 188 patients were enrolled in this study. The rate of collection of baseline QOL sheets was 98.0%. The rate of answer to questions of QOL sheets was 99.0%. At baseline, the average score of FACT-G, P was 120.7 and the maximum score was more than twice the minimum score. Dysfunction of urination and bowel movement was correlated with the bother of urination and bowel movement, respectively. On the other hand, dysfunction of sexual activity was not correlated with the bother of sexual activity. In June 2003, all of the QOL sheets at baseline, and at 6, 8, and 14 months were completely collected from a total of 72 patients. Although QOL at 8 months was significantly affected compared with QOL at baseline and at 6 months, QOL at 14 months was significantly improved compared with that at 8 months and there was no significant

  14. Synchronization of indirectly coupled Lorenz oscillators

    Indian Academy of Sciences (India)

    Synchronization of indirectly coupled Lorenz oscillators: An experimental study. Amit Sharma Manish Dev Shrimali. Synchronization, Coupled Systems and Networks Volume 77 Issue 5 November 2011 pp 881-889 ... The in-phase and anti-phase synchronization of indirectly coupled chaotic oscillators reported in Phys. Rev ...

  15. Indirect search for dark matter with AMS

    International Nuclear Information System (INIS)

    Goy, Corinne

    2006-01-01

    This document summarises the potential of AMS in the indirect search for Dark Matter. Observations and cosmology indicate that the Universe may include a large amount of Dark Matter of unknown nature. A good candidate is the Ligthest Supersymmetric Particle in R-Parity conserving models. AMS offers a unique opportunity to study Dark Matter indirect signature in three spectra: gamma, antiprotons and positrons

  16. Indirectness in Discourse: Ethnicity as Conversational Style.

    Science.gov (United States)

    Tannen, Deborah

    1981-01-01

    Examines social differences in expectations of indirectness in conversations between married couples, both Greek and Greek-American. Concludes that Greeks are more likely to expect indirectness in the context presented and that Greek-Americans have retained the Greek communicative patterns. (FL)

  17. JUSTIFICATION FOR INDIRECT DISCRIMINATION IN EU

    Directory of Open Access Journals (Sweden)

    Cătălina-Adriana Ivănuş

    2014-11-01

    Full Text Available The right to non-discrimination is very important for a civilized society. EU legislation establishes direct and indirect discrimination, harassment, sexual harassment, instruction to discriminate and any less favourable treatment of a woman related to pregnancy or maternity leave as forms of discrimination. The law and the Court of Justice permit the justification of indirect discrimination.

  18. 77 FR 41899 - Indirect Food Additives: Polymers

    Science.gov (United States)

    2012-07-17

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 177 [Docket No. FDA-2012-F-0031] Indirect Food Additives: Polymers AGENCY: Food and Drug Administration, HHS. ACTION... CFR part 177 is amended as follows: PART 177--INDIRECT FOOD ADDITIVES: POLYMERS 0 1. The authority...

  19. JUSTIFICATION FOR INDIRECT DISCRIMINATION IN EU

    OpenAIRE

    Cătălina-Adriana Ivănuş

    2014-01-01

    The right to non-discrimination is very important for a civilized society. EU legislation establishes direct and indirect discrimination, harassment, sexual harassment, instruction to discriminate and any less favourable treatment of a woman related to pregnancy or maternity leave as forms of discrimination. The law and the Court of Justice permit the justification of indirect discrimination.

  20. Indirect techniques in nuclear astrophysics: a review.

    Science.gov (United States)

    Tribble, R E; Bertulani, C A; Cognata, M La; Mukhamedzhanov, A M; Spitaleri, C

    2014-10-01

    In this review, we discuss the present status of three indirect techniques that are used to determine reaction rates for stellar burning processes, asymptotic normalization coefficients, the Trojan Horse method and Coulomb dissociation. A comprehensive review of the theory behind each of these techniques is presented. This is followed by an overview of the experiments that have been carried out using these indirect approaches.

  1. Picosecond calorimetry

    DEFF Research Database (Denmark)

    Georgiou, Panayiotis; Vincent, Jonathan; Andersson, Magnus

    2006-01-01

    to rapidly heat liquid C H2 Cl2 using UV pulses of 100 fs duration. A significant x-ray diffraction signal is visible prior to the onset of thermal expansion, which characterizes a highly compressed superheated liquid. Liquid C H2 Cl2 then expands as a shock wave propagates through the sample...

  2. Expression of future prospective in indirect speech

    Directory of Open Access Journals (Sweden)

    Bodnaruk Elena Vladimirovna

    2015-03-01

    Full Text Available The article analyzes the characteristics and use of grammatical semantics and lexical and grammatical means used to create future prospects in double indirect discourse. The material for the study were epic works by contemporary German writers. In the analysis of the empirical material it has been pointed out that indirect discourse has preterial basis and is the kind of most frequent inner speech of characters. The most widely used form with future semantics in preterial indirect speech is conditional I, formally having a conjunctive basis, but is mostly used with the indicative semantics. Competitive to conditional I in indirect speech is preterial indicative. A characteristic feature of the indirect speech is the use of modal verbs, which, thanks to its semantics is usually referred as an action at a later term, creating the prospect of future statements. The most frequent were modal verbs wollen and sollen in the form of the preterite, more rare verbs were m ssen and k nnen. German indirect speech distinguishes the ability to use forms on the basis of conjunctive: preterite and plusquamperfect of conjunctive. Both forms express values similar to those of the indicative. However, conjunctive forms the basis of the data shown in a slightly more pronounced seme of uncertainty that accompanies future uses of these forms in indirect speech. In addition, plusquamperfect conjunctive differs from others by the presence of the seme of completeness.

  3. Comparison of calorimetry and destructive analytical measurement techniques for excess plutonium powders

    International Nuclear Information System (INIS)

    Welsh, T.L.

    1996-01-01

    In Dec. 1994, IAEA safeguards were initiated on inventory of Pu- bearing materials, originating from the US nuclear weapons complex, at vault 3 of DOE's Plutonium Finishing Plant at Hanford. Because of the diversity and heterogeneity of the Pu, plant operators have increasingly used calorimetry for accountability measurements. During the recent commencement of IAEA safeguards at vault 3, destructive (electrochemical titration) methods were used to determine Pu concentrations in subsamples of inventory items with widely ranging chemical purities. The Pu concentrations in the subsamples were determined and contribution of heterogeneity to total variability was identified. Measurement results, gathered by PFP and IAEA laboratories, showed total measurement variability for calorimetry to be comparable with or lower than those of sampling and chemical analyses

  4. Application of isothermal calorimetry and uv spectroscopy for stability monitoring of pentaerythritol tetranitrate

    International Nuclear Information System (INIS)

    Dosser, L.R.; Pickard, J.M.

    1992-01-01

    Thermal stabilities for a series of pentaerythritol-tetranitrate (PETN) samples with variable surf ace areas were monitored by isothermal calorimetry and UV spectroscopy over the temperature range of 363 to 408 K. Isothermal induction times measured with constant volume calorimetry under an air atmosphere and No evolution rates monitored by UV absorbance at 213 nm under vacuum correlated with the PETN surface area at temperatures equal to or exceeding 383 K. Rate data measured at 383 K are in accord with predictions based on detailed kinetic modeling. Below 383 K, NO evolution data suggested that additional geometric factors may be significant in controlling PETN stability. Mechanisms for influencing surface area upon the rate-determining step are addressed

  5. Radiation damage study for silicon calorimetry: Summary of first year's activity

    International Nuclear Information System (INIS)

    Russ, J.S.

    1988-01-01

    In the first contract year of this activity at Carnegie-Mellon we have had two major objectives. These were to devise and test a non-intrusive means to measure the energy and spatial profiles of the neutrons generated in a hadronic cascade at high energy; and to study the calibration systematics of silicon diode detectors as a prelude to their evaluation for SSC calorimetry. These objectives have been carried out, as are described in this paper. In addition we have recoded the ORNL detector simulation program HETC to operate on a VAX and are working on the conversion of the low energy neutron transport program MORSE. These programs are used heavily at Oak Ridge (Gabriel and coworkers) for cascade studies. For silicon calorimetry one wants to have more control over the energy deposition routines, especially in MORSE. Unfortunately, MORSE is heavily-laden with machine code, and its conversion is going slowly. 11 refs., 5 figs

  6. Laser Calorimetry Spectroscopy for ppm-level Dissolved Gas Detection and Analysis.

    Science.gov (United States)

    K S, Nagapriya; Sinha, Shashank; R, Prashanth; Poonacha, Samhitha; Chaudhry, Gunaranjan; Bhattacharya, Anandaroop; Choudhury, Niloy; Mahalik, Saroj; Maity, Sandip

    2017-02-20

    In this paper we report a newly developed technique - laser calorimetry spectroscopy (LCS), which is a combination of laser absorption spectroscopy and calorimetry - for the detection of gases dissolved in liquids. The technique involves determination of concentration of a dissolved gas by irradiating the liquid with light of a wavelength where the gas absorbs, and measuring the temperature change caused by the absorbance. Conventionally, detection of dissolved gases with sufficient sensitivity and specificity was done by first extracting the gases from the liquid and then analyzing the gases using techniques such as gas chromatography. Using LCS, we have been able to detect ppm levels of dissolved gases without extracting them from the liquid. In this paper, we show the detection of dissolved acetylene in transformer oil in the mid infrared (MIR) wavelength (3021 nm) region.

  7. Modulated Temperature Differential Scanning Calorimetry Theoretical and Practical Applications in Polymer Characterisation

    CERN Document Server

    Reading, Mike

    2006-01-01

    MTDSC provides a step-change increase in the power of calorimetry to characterize virtually all polymer systems including curing systems, blends and semicrystalline polymers. It enables hidden transitions to be revealed, miscibility to be accurately assessed, and phases and interfaces in complex blends to be quantified. It also enables crystallinity in complex systems to be measured and provides new insights into melting behaviour. All of this is achieved by a simple modification of conventional DSC. In 1992 a new calorimetric technique was introduced that superimposed a small modulation on top of the conventional linear temperature program typically used in differential scanning calorimetry. This was combined with a method of data analysis that enabled the sample’s response to the linear component of the temperature program to be separated from its response to the periodic component. In this way, for the first time, a signal equivalent to that of conventional DSC was obtained simultaneously with a measure ...

  8. Characterization of the phase transformations in shape-memory alloys by modulated differential scanning calorimetry

    International Nuclear Information System (INIS)

    Wei, Z.G.; Sandstroem, R.

    1999-01-01

    Modulated differential scanning calorimetry (MDSC) is a recently developed calorimetric technique, which has demonstrated some significant advantages over the conventional differential scanning calorimetry (DSC). By separating the reversing quantity from the non-reversing component in the total thermal events, it provides some new information that can not be obtained from the conventional DSC. The technique has been applied to various polycrystalline and single crystalline shape-memory alloys, including Cu-Zn-Al, Cu-Al-Ni, Ti-Ni(Cu), Ni-Mn-Ga and Fe-Mn-Si, to characterize the martensitic transformations, bainitic transformation, chemical and magnetic ordering transitions, atomic reordering and other kinetic relaxation processes in the alloys. The preliminary results of the MDSC measurements are summarized and the interpretation of the MDSC results and some factors affecting the results are discussed. (orig.)

  9. Inherent limitations of fixed-time, servo-controlled radiometric calorimetry

    International Nuclear Information System (INIS)

    Wetzel, J.R.; Lemming, J.F.; Duff, M.F.

    1987-01-01

    Interest has been shown in using fixed-time, servo-controlled calorimetry to shorten the measurement times for certain samples that require low precision values (3 to 5%). This type of calorimeter measurement could be particularly useful for screening scrap samples to determine whether there is a need for a more accurate measurement or for certain confirmatory measurements for which low precision numbers are sufficient. The equipment required for this type of measurement is a servo-controlled calorimeter and a preconditioning unit. Samples to be measured are placed in the preconditioning unit, which is maintained at the internal temperature of the calorimeter. The power value for the sample is determined at a fixed time after loading into the calorimeter, for example, 30 min. When a calorimeter is operated using a fixed cutoff time, there are additional sources of uncertainty that need to be considered. The major factors affecting the uncertainty of the calorimetry power values are discussed. 2 refs., 4 figs

  10. Immersion Calorimetry for the Characterization of PD Catalysts Supported on Activated Carbon

    Directory of Open Access Journals (Sweden)

    Liliana Giraldo

    2009-01-01

    Full Text Available Activated carbons obtained from coconut peel were oxidized using hydrogen peroxide. Superficial characteristics of these carbons were determined through N2 and CO2 isotherms and functional groups were characterized by TPD. Finally, the microcalorimetry technique was used in order to obtain the immersion enthalpies in diverse liquids and established the relation between them and the results obtained by the other characterization techniques. The results suggested that the immersion calorimetry allow establishing the difference between the supports and the catalysts.

  11. Monitoring of an RNA Multistep Folding Pathway by Isothermal Titration Calorimetry

    OpenAIRE

    Reymond, Cédric; Bisaillon, Martin; Perreault, Jean-Pierre

    2009-01-01

    Isothermal titration calorimetry was used to monitor the energetic landscape of a catalytic RNA, specifically that of the hepatitis delta virus ribozyme. Using mutants that isolated various tertiary interactions, the thermodynamic parameters of several ribozyme-substrate intermediates were determined. The results shed light on the impact of several tertiary interactions on the global structure of the ribozyme. In addition, the data indicate that the formation of the P1.1 pseudoknot is the lim...

  12. Low-temperature heat capacity of small Nb3Sn polycrystals by ac calorimetry

    International Nuclear Information System (INIS)

    Viswanathan, R.; Johnston, D.C.

    1976-01-01

    It is shown by an ac calorimetry technique that the multiple heat capacity anomalies which occur below the superconducting transition temperature for small polycrystalline Nb 3 Sn samples are intrinsic to these samples. The recent suggestions that shear stresses can account for these results are analyzed for their validity. The dependence of the occurrence of these multiple anomalies upon the thermal history of the samples was investigated

  13. A survey of the year 2007 literature on applications of isothermal titration calorimetry

    OpenAIRE

    Bjelic, S; Jelesarov, I

    2008-01-01

    Elucidation of the energetic principles of binding affinity and specificity is a central task in many branches of current sciences: biology, medicine, pharmacology, chemistry, material sciences, etc. In biomedical research, integral approaches combining structural information with in-solution biophysical data have proved to be a powerful way toward understanding the physical basis of vital cellular phenomena. Isothermal titration calorimetry (ITC) is a valuable experimental tool facilitating ...

  14. Photothermal beam deflection calorimetry in solution photochemistry: recent progress and future prospects.

    Science.gov (United States)

    Falvey, D E

    1997-01-01

    Photothermal beam deflection (PBD) calorimetry is a technique that measures changes in the solvent's refractive index that accompanies photothermal heating. This method is capable of extracting both kinetic and thermodynamic information from photochemical reactions. A qualitative description of physical basis of time-resolved PBD is presented. Several recent examples of its application to photochemical and photobiological problems are discussed. Finally, the advantages and limitations of PBD are described.

  15. Application of calorimetry in evaluation of phase transformations in the selected hypoeutectic silumins

    Directory of Open Access Journals (Sweden)

    J. Szymszal

    2009-04-01

    Full Text Available The investigations of phase transformations described in this study were carried out on hypoeutectic alloys from the Al-Si during heating and cooling. The determination and analysis of characteristic temperature values from the solidification range was made by the DSC method in calorimetric investigations carried out on a high-temperature multi HTC Setaram scanning calorimeter. Applying the lever rule, the phase composition of the examined slumins was calculated and compared with the results of DSC calorimetry.

  16. A bipolar monolithic preamplifier for high-capacitance SSC [Superconducting Super Collider] silicon calorimetry

    International Nuclear Information System (INIS)

    Britton, C.L. Jr.; Kennedy, E.J.; Bugg, W.M.

    1990-01-01

    This paper describes a preamplifier designed and fabricated specifically to address the requirements of silicon calorimetry for the Superconducting Super Collider (SSC). The topology and its features are discussed in addition to the design methodology employed. The simulated and measured results for noise, power consumption, and speed are presented. Simulated an measured data for radiation damage effects as well as data for post-damage annealing are also presented. 8 refs., 7 figs., 2 tabs

  17. Advanced forward calorimetry for the SSC and TeVatron collider

    International Nuclear Information System (INIS)

    DiBitonto, D.; Van Peteghem, P.M.; Geiger, R.L.; McIntyre, P.M.; Pang, Y.; Thane, J.M.; White, J.T.; Atac, M.

    1989-01-01

    We describe a project to develop fast, radiation hardened forward calorimetry for the SSC and TeVatron collider. Detector technologies discussed are based on gas and warm liquid media. In particular, we present the design of an ultrasensitive hybrid charge preamplifier for liquid technology capable of operating at 0.1-1 GHz. The actual detector bandwidth will depend on the choice of detector media used and the maximum allowable operating high voltage. (orig.)

  18. Recent advances and potential applications of modulated differential scanning calorimetry (mDSC) in drug development

    DEFF Research Database (Denmark)

    Knopp, Matthias Manne; Löbmann, Korbinian; Elder, David P.

    2016-01-01

    Differential scanning calorimetry (DSC) is frequently the thermal analysis technique of choice within preformulation and formulation sciences because of its ability to provide detailed information about both the physical and energetic properties of a substance and/or formulation. However, convent......-dried formulations. However, as discussed in the present review, a number of other potential applications could also be relevant for the pharmaceutical scientist....

  19. Determination of the aggregation number for micelles by isothermal titration calorimetry

    DEFF Research Database (Denmark)

    Olesen, Niels Erik; Holm, Rene; Westh, Peter

    2014-01-01

    Isothermal titration calorimetry (ITC) has previously been applied to estimate the aggregation number (n), Gibbs free energy (ΔG), enthalpy (ΔH) and entropy (ΔS) of micellization. However, some difficulties of micelle characterization by ITC still remain; most micelles have aggregation numbers...... insight into optimal design of titration protocols for micelle characterization. By applying the new method, the aggregation number of sodium dodecyl sulphate and glycochenodeoxycholate was determined at concentrations around their critical micelle concentration (CMC)...

  20. Indirect estimators in US federal programs

    CERN Document Server

    1996-01-01

    In 1991, a subcommittee of the Federal Committee on Statistical Methodology met to document the use of indirect estimators - that is, estimators which use data drawn from a domain or time different from the domain or time for which an estimate is required. This volume comprises the eight reports which describe the use of indirect estimators and they are based on case studies from a variety of federal programs. As a result, many researchers will find this book provides a valuable survey of how indirect estimators are used in practice and which addresses some of the pitfalls of these methods.

  1. CALOR2012 XVth International Conference on Calorimetry in High Energy Physics

    Energy Technology Data Exchange (ETDEWEB)

    Akchurin, Nural .

    2015-05-04

    The International Conferences on Calorimetry in High Energy Physics, or the CALOR series, have always been where the calorimeter experts come together to review the state of calorimetry and bring forth new ideas every two years. The fteenth conference, CALOR2012, in Santa Fe was no exception. Although they were built roughly a decade ago, we are now witnessing the exceptional power of the LHC calorimeters and the crucial role they have been playing in the discovery of the 125 GeV Higgs-like boson. As we ruminate on the coming generation of experiments at the next (linear) collider and on the upgrades at the LHC, we are heartened by the substantial advances we made in calorimetry in the last decade. These advances will certainly help uncover new physics in the years to come, not only at colliders but also in astroparticle experiments that take advantage of natural elements such as air, water, and ice. The proceedings were published by the IOP in Journal of Physics, Vol 404 2011. The conference web site is calor2012.ttu.edu.

  2. Ionic liquids. Combination of combustion calorimetry with high-level quantum chemical calculations for deriving vaporization enthalpies.

    Science.gov (United States)

    Emel'yanenko, Vladimir N; Verevkin, Sergey P; Heintz, Andreas; Schick, Christoph

    2008-07-10

    In this work, the molar enthalpies of formation of the ionic liquids [C2MIM][NO3] and [C4MIM][NO3] were measured by means of combustion calorimetry. The molar enthalpy of fusion of [C2MIM][NO3] was measured using differential scanning calorimetry. Ab initio calculations of the enthalpy of formation in the gaseous phase have been performed for the ionic species using the G3MP2 theory. We have used a combination of traditional combustion calorimetry with modern high-level ab initio calculations in order to obtain the molar enthalpies of vaporization of a series of the ionic liquids under study.

  3. Bioelectrochemical Systems for Indirect Biohydrogen Production

    KAUST Repository

    Regan, John M.; Yan, Hengjing

    2014-01-01

    by exoelectrogens at the anode. As an indirect approach to biohydrogen production, these systems are not subject to the hydrogen yield constraints of fermentative processes and have been proven to work with virtually any biodegradable organic substrate

  4. Indirect techniques in nuclear astrophysics: a review

    International Nuclear Information System (INIS)

    Tribble, R E; Mukhamedzhanov, A M; Bertulani, C A; Cognata, M La; Spitaleri, C

    2014-01-01

    In this review, we discuss the present status of three indirect techniques that are used to determine reaction rates for stellar burning processes, asymptotic normalization coefficients, the Trojan Horse method and Coulomb dissociation. A comprehensive review of the theory behind each of these techniques is presented. This is followed by an overview of the experiments that have been carried out using these indirect approaches. (review article)

  5. An Indirect Route for Ethanol Production

    Energy Technology Data Exchange (ETDEWEB)

    Eggeman, T.; Verser, D.; Weber, E.

    2005-04-29

    The ZeaChem indirect method is a radically new approach to producing fuel ethanol from renewable resources. Sugar and syngas processing platforms are combined in a novel way that allows all fractions of biomass feedstocks (e.g. carbohydrates, lignins, etc.) to contribute their energy directly into the ethanol product via fermentation and hydrogen based chemical process technologies. The goals of this project were: (1) Collect engineering data necessary for scale-up of the indirect route for ethanol production, and (2) Produce process and economic models to guide the development effort. Both goals were successfully accomplished. The projected economics of the Base Case developed in this work are comparable to today's corn based ethanol technology. Sensitivity analysis shows that significant improvements in economics for the indirect route would result if a biomass feedstock rather that starch hydrolyzate were used as the carbohydrate source. The energy ratio, defined as the ratio of green energy produced divided by the amount of fossil energy consumed, is projected to be 3.11 to 12.32 for the indirect route depending upon the details of implementation. Conventional technology has an energy ratio of 1.34, thus the indirect route will have a significant environmental advantage over today's technology. Energy savings of 7.48 trillion Btu/yr will result when 100 MMgal/yr (neat) of ethanol capacity via the indirect route is placed on-line by the year 2010.

  6. How good is technetium-99m mercaptoacetyltriglycine indirect cystography?

    International Nuclear Information System (INIS)

    Sadeleer, C. de; Boe, V. de; Keuppens, F.; Desprechins, B.; Verboven, M.; Piepsz, A.

    1994-01-01

    The aim of the present study was to estimate the sensitivity of indirect radionuclide cystography (IRC) performed with technetium-99m mercaptoacetyltriglycine (MAG3), in comparison with the micturition cystourethrography (MCUG) and direct radionuclide cystography (DRC), for the diagnosis of vesicoureteric reflux. Two groups of patients were selected: group I comprised 40 children who underwent IRC during the acute phase of urinary tract infection and an MCUG 6 weeks later; group II comprised 42 (other) children with known reflux, who underwent IRC and DRC during follow-up. Taking as the reference the total number of refluxing kidneys detected by means of any cystographic technique, 99m Tc-MAG3 ICR missed two-thirds of the refluxing kidneys. Most of the small refluxes were missed, but so too were 50% of the major refluxes. Taking as the reference 99m Tc dimercaptosuccinic acid (DMSA) scintigraphy, MCUG detected 91% of the patients with DMSA abnormalities on at least one kidney, DRC detected 95%, and IRC detected 46% and 43% respectively, in groups I and II. The use of 99m Tc-MAG3 IRC as the sole technique for the detection of vesicoureteric reflux gives rise to an unacceptable number of false-negative results. (orig.)

  7. Immersion calorimetry as a tool to evaluate the catalytic performance of titanosilicate materials in the epoxidation of cyclohexene.

    Science.gov (United States)

    Vernimmen, Jarian; Guidotti, Matteo; Silvestre-Albero, Joaquin; Jardim, Erika O; Mertens, Myrjam; Lebedev, Oleg I; Van Tendeloo, Gustaaf; Psaro, Rinaldo; Rodríguez-Reinoso, Francisco; Meynen, Vera; Cool, Pegie

    2011-04-05

    Different types of titanosilicates are synthesized, structurally characterized, and subsequently catalytically tested in the liquid-phase epoxidation of cyclohexene. The performance of three types of combined zeolitic/mesoporous materials is compared with that of widely studied Ti-grafted-MCM-41 molecular sieve and the TS-1 microporous titanosilicate. The catalytic test results are correlated with the structural characteristics of the different catalysts. Moreover, for the first time, immersion calorimetry with the same substrate molecule as in the catalytic test reaction is applied as an extra means to interpret the catalytic results. A good correlation between catalytic performance and immersion calorimetry results is found. This work points out that the combination of catalytic testing and immersion calorimetry can lead to important insights into the influence of the materials structural characteristics on catalysis. Moreover, the potential of using immersion calorimetry as a screening tool for catalysts in epoxidation reactions is shown.

  8. [Findings from Total Colonoscopy in Obstructive Colorectal Cancer Patients Who Underwent Stent Placement as a Bridge to Surgery(BTS)].

    Science.gov (United States)

    Maruo, Hirotoshi; Tsuyuki, Hajime; Kojima, Tadahiro; Koreyasu, Ryohei; Nakamura, Koichi; Higashi, Yukihiro; Shoji, Tsuyoshi; Yamazaki, Masanori; Nishiyama, Raisuke; Ito, Tatsuhiro; Koike, Kota; Ikeda, Takashi; Takayanagi, Yasuhiro; Kubota, Hiroyuki

    2017-11-01

    We clinically investigated 34 patients with obstructive colorectal cancer who underwent placement of a colonic stent as a bridge to surgery(BTS), focusing on endoscopic findings after stent placement.Twenty -nine patients(85.3%)underwent colonoscopy after stent placement, and the entire large intestine could be observed in 28(96.6%).Coexisting lesions were observed in 22(78.6%)of these 28 patients.The lesions comprised adenomatous polyps in 17 patients(60.7%), synchronous colon cancers in 5 patients(17.9%), and obstructive colitis in 3 patients(10.7%), with some overlapping cases.All patients with multiple cancers underwent one-stage surgery, and all lesions were excised at the same time.Colonoscopy after colonic stent placement is important for preoperative diagnosis of coexisting lesions and planning the extent of resection. These considerations support the utility of colonic stenting for BTS.

  9. Analysis of indirect taxation in Ukraine

    Directory of Open Access Journals (Sweden)

    Khodyakova Olga V.

    2014-01-01

    Full Text Available The goal of the article is analysis of the structure and dynamics of indirect taxes for the previous five years and also the influence of indirect taxation upon formation of income of the State Budget of Ukraine. The article analyses the modern state of indirect taxation in Ukraine. Specific weight of the value added tax, excise tax and customs duty are considered in the structure of tax receipts of the consolidated budget of Ukraine as indirect taxes. The article shows that receipts of the State Budget of Ukraine are mostly provided by indirect taxes. The Ukrainian taxation system is mostly a factor of reduction of the level of economic growth and investment activity in the country and the existing system of administering is not completely capable of excluding the possibility of tax evasion. The prospect of further studies in this direction is improvement of organisation of tax control in Ukraine and differentiation of the value added tax rates depending on the level of consumption of goods and level of income of consumers.

  10. Water calorimetry and ionization chamber dosimetry in an 85-MeV clinical proton beam.

    Science.gov (United States)

    Palmans, H; Seuntjens, J; Verhaegen, F; Denis, J M; Vynckier, S; Thierens, H

    1996-05-01

    In recent years, the increased use of proton beams for clinical purposes has enhanced the demand for accurate absolute dosimetry for protons. As calorimetry is the most direct way to establish the absorbed dose and because water has recently been accepted as standard material for this type of beam, the importance of water calorimetry is obvious. In this work we report water calorimeter operation in an 85-MeV proton beam and a comparison of the absorbed dose to water measured by ionometry with the dose resulting from water calorimetric measurements. To ensure a proper understanding of the heat defect for defined impurities in water for this type of radiation, a relative response study was first done in comparison with theoretical calculations of the heat defect. The results showed that pure hypoxic water and hydrogen-saturated water yielded the same response with practically zero heat defect, in agreement with the model calculations. The absorbed dose inferred from these measurements was then compared with the dose derived from ionometry by applying the European Charged Heavy Particle Dosimetry (ECHED) protocol. Restricting the comparison to chambers recommended in the protocol, the calorimeter dose was found to be 2.6% +/- 0.9% lower than the average ionometry dose. In order to estimate the significance of chamber-dependent effects in this deviation, measurements were performed using a set of ten ionization chambers of five different types. The maximum internal deviation in the ionometry results amounted to 1.1%. We detected no systematic chamber volume dependence, but observed a small but systematic effect of the chamber wall thickness. The observed deviation between calorimetry and ionometry can be attributed to a combination of the value of (Wair/e)p for protons, adopted in the ECHED protocol, the mass stopping power ratios of water to air for protons, and possibly small ionization chamber wall effects.

  11. pytc: Open-Source Python Software for Global Analyses of Isothermal Titration Calorimetry Data.

    Science.gov (United States)

    Duvvuri, Hiranmayi; Wheeler, Lucas C; Harms, Michael J

    2018-05-08

    Here we describe pytc, an open-source Python package for global fits of thermodynamic models to multiple isothermal titration calorimetry experiments. Key features include simplicity, the ability to implement new thermodynamic models, a robust maximum likelihood fitter, a fast Bayesian Markov-Chain Monte Carlo sampler, rigorous implementation, extensive documentation, and full cross-platform compatibility. pytc fitting can be done using an application program interface or via a graphical user interface. It is available for download at https://github.com/harmslab/pytc .

  12. Determination of magnetic characteristics of nanoparticles by low-temperature calorimetry methods

    Energy Technology Data Exchange (ETDEWEB)

    Ugulava, A.; Toklikishvili, Z. [Department of Physics, I.Javakhishvili Tbilisi State University,I.Chavchavadze av. 3, 0179 Tbilisi, Georgia (United States); Chkhaidze, S., E-mail: simon.chkhaidze@tsu.ge [Department of Physics, I.Javakhishvili Tbilisi State University,I.Chavchavadze av. 3, 0179 Tbilisi, Georgia (United States); Kekutia, Sh. [V. Chavchanidze Institute of Cybernetics, at the Technical State University, S. Euli str. 5, 0186 Tbilisi, Georgia (United States)

    2017-05-15

    At low temperatures, the heat capacity of a superparamagnetic “ideal gas” determined by magnetic degrees of freedom can greatly exceed the lattice heat capacity. It is shown that in the presence of an external magnetic field, the temperature dependence of the magnetic part of the heat capacity has two maxima. The relations between the temperature at which these maxima are achieved, the magnetic moment of the nanoparticles and the magnetic anisotropy constant have been obtained. Measuring the heat capacity maxima temperatures by low-temperature calorimetry methods and using the obtained relations, we can obtain the numerical values both of the magnetic moment of nanoparticles and the magnetic anisotropy constants.

  13. Physico-chemical changes in heavy ions irradiated polymer foils by differential scanning calorimetry

    International Nuclear Information System (INIS)

    Ciesla, K.; Trautmann, Ch.; Vansant, E.F.

    1994-01-01

    The sample of commercial PETP (Hostaphan) and very heavy ions irradiated products were investigated by differential scanning calorimetry in nitrogen flow. Irradiation were performed with Dy ions of 13 MeV/u with fluences 5 x 10 10 ions/cm 2 . Differences were observed in melting behaviour of unirradiated and irradiated foils. The influence of irradiation conditions on the results was noticed. Moreover the samples of polyimide (Kapton) and polycarbonate (Macrofol) irradiated in similar conditions were examined by DSC. The DSC traces have been compared with those of unirradiated reference samples. (author). 8 refs, 5 figs

  14. Test in a beam of large-area Micromegas chambers for sampling calorimetry

    CERN Document Server

    Adloff, C.; Dalmaz, A.; Drancourt, C.; Gaglione, R.; Geffroy, N.; Jacquemier, J.; Karyotakis, Y.; Koletsou, I.; Peltier, F.; Samarati, J.; Vouters, G.

    2014-06-11

    Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density deposits are prerequisites to achieving good energy resolution. A Micromegas-based hadronic calorimeter was proposed for an application at a future linear collider experiment and three technologically advanced prototypes of 1$\\times$1 m$^{2}$ were constructed. Their merits relative to the above-mentioned criteria are discussed on the basis of measurements performed at the CERN SPS test-beam facility.

  15. Calorimetry of Pu in the context of fuel fabrication follow-up

    International Nuclear Information System (INIS)

    Sanson, C.; Arnal, Thierry

    1979-01-01

    Calorimetry appears to be a particularly attractive method for obtaining balances within the context of fuel fabrication follow-up. Under this method the heat released by any plutonium sample is determined with calorimeters fitted with thermocouples, thereby ensuring perfect stability in time response. The first results achieved with two inexpensive prototype calorimeters are as follows, so far: response time, six hours approximately; sensitivity greater than 4 mv.W -1 and repeatability in the order 1%. It will no doubt be possible to improve this performance to a notable extent in the near future [fr

  16. Insights into glass transition and relaxation behavior using temperature-modulated differential scanning calorimetry

    DEFF Research Database (Denmark)

    Guo, Xiaoju; Mauro, J.C.; Allan, D.C.

    Temperature-modulated differential scanning calorimetry (TMDSC) is based on conventional DSC but with a sinusoidally modulated temperature path. Our simulations of TMDSC signals prove that the frequency correction of non-reversing heat flow can give a master curve within a certain range...... of frequencies. This frequency range is dependent not only on the measurement parameters such as linear heating/cooling rate and frequency and amplitude of the modulation, but also on the previous thermal history before the TMDSC measurement. The frequency correction for the reversing heat flow gives more...

  17. On the Frequency Correction in Temperature-Modulated Differential Scanning Calorimetry of Glass Transition

    DEFF Research Database (Denmark)

    Guo, Xiaoju; Mauro, J.C.; Allan, D.C.

    2012-01-01

    Temperature-modulated differential scanning calorimetry (TMDSC) is based on conventional DSC but with a sinusoidally modulated temperature path. Simulations of TMDSC signals were performed for Corning EAGLE XG® glass over a wide range of modulation frequencies. Our results reveal that the frequency...... correction commonly used in the interpretation of TMDSC signals leads to a master nonreversing heat flow curve independent of modulation frequency, provided that sufficiently high frequencies are employed in the TMDSC measurement. A master reversing heat flow curve can also be generated through the frequency...

  18. A novel calorimetry technique for monitoring electron beam curing of polymer resins

    International Nuclear Information System (INIS)

    Chen, J.H.; Johnston, A.; Petrescue, L.; Hojjati, M.

    2006-01-01

    This paper describes the development of a calorimetry-based technique for monitoring of the curing of electron beam (EB) curable resins, including design of the calorimeter hardware and the development of an analytical model for calculating resin cure rates and radiation dose. Factors affecting the performance of the calorimeter were investigated. Experimental trials monitoring the curing of epoxy resin were conducted under single pass and multiple passes of EB irradiation. Results show that the developed calorimeter is a simple, inexpensive and reasonably accurate technique for monitoring the EB curing of cationic epoxies

  19. Conductivity, calorimetry and phase diagram of the NaHSO4–KHSO4 system

    DEFF Research Database (Denmark)

    Hind, Hamma-Cugny; Rasmussen, Søren Birk; Rogez, J.

    2006-01-01

    to polynomials of the form κ(X)=A(X)+B(X)(T-Tm)+C(X)(T-Tm)2, where Tm is the intermediate temperature of the measured temperature range and X, the mole fraction of KHSO4. The possible role of this binary system as a catalyst solvent is also discussed. (C) 2005 Elsevier B.V. All rights reserved.......Physico-chemical properties of the binary system NaHSO4-KHSO4 were studied by calorimetry and conductivity, The enthalpy of mixing has been measured at 505 K in the full composition range and the phase diagram calculated. The phase diagram has also been constructed from phase transition...

  20. Impact of Polypharmacy on Adherence to Evidence-Based Medication in Patients who Underwent Percutaneous Coronary Intervention.

    Science.gov (United States)

    Mohammed, Shaban; Arabi, Abdulrahaman; El-Menyar, Ayman; Abdulkarim, Sabir; AlJundi, Amer; Alqahtani, Awad; Arafa, Salah; Al Suwaidi, Jassim

    2016-01-01

    The primary objective of this study was to evaluate the impact of polypharmacy on primary and secondary adherence to evidence-based medication (EBM) and to measure factors associated with non-adherence among patients who underwent percutaneous coronary intervention (PCI). We conducted a retrospective analysis for patients who underwent PCI at a tertiary cardiac care hospital in Qatar. Patients who had polypharmacy (defined as ≥6 medications) were compared with those who had no polypharmacy at hospital discharge in terms of primary and secondary adherence to dual antiplatelet therapy (DAPT), beta-blockers (BB), angiotensin converting enzyme inhibitors (ACEIs) and statins. A total of 557 patients (mean age: 53±10 years; 85%; males) who underwent PCI were included. The majority of patients (84.6%) received ≥6 medications (polypharmacy group) while only 15.4% patients received ≥5 medications (nonpolypharmacy group). The two groups were comparable in term of gender, nationality, socioeconomic status and medical insurance. The non-polypharmacy patients had significantly higher adherence to first refill of DAPT compared with patients in the polypharmacy group (100 vs. 76.9%; p=0.001). Similarly, the non-polypharmacy patients were significantly more adherent to secondary preventive medications (BB, ACEI and statins) than the polypharmacy group. In patients who underwent PCI, polypharmacy at discharge could play a negative role in the adherence to the first refill of EBM. Further studies should investigate other parameters that contribute to long term non-adherence.

  1. A review of Indirect Matrix Converter Topologies

    Directory of Open Access Journals (Sweden)

    Salem Rahmani

    2015-08-01

    Full Text Available Abstract—Matrix Converter (MC is a modern direct AC/AC electrical power converter without dc-link capacitor. MC is operated in four quadrant, assuring a control of the output voltage, amplitude and frequency. The matrix converter has recently attracted significant attention among researchers and it has become increasing attractive for applications of wind energy conversion, military power supplies, induction motor drives, etc. Recently, different MC topologies have been proposed and developed which have their own advantages and disadvantages. Matrix converter can be classified as direct and indirect structures. The direct one has been elaborated in previous work. In this paper the indirect MCs are reviewed. Different characteristics of the indirect MC topologies are mentioned to show the strengths and weaknesses of such converter topologies.

  2. Indirect taxes on food in Southern Brazil

    Directory of Open Access Journals (Sweden)

    Denize Mirian da Silva

    2013-12-01

    Full Text Available The objective of this paper is to estimate the indirect tax burden on food for ten income classes, based on income and household total expenditure in southern Brazil. Thus it can be seen as indirect taxes on foods affect the monetary income and consumption pattern of households. To reach the objectives proposed, will be used the Pintos-Payeras (2008 model. The database iscomposed by microdata from the Household Budgeting Survey (POF 2008-2009 and the tax regulations of the country and the southern states of Brazil. The results show that indirect taxes on food in Southern Brazil is regressive when based on income and expenditure of household , ie , the poorest people pay proportionately more taxes and have their consumption pattern highest taxed ICMS (Brazilian value added tax is the tax that contributes most to the regressivity.

  3. Ballistic fractures: indirect fracture to bone.

    Science.gov (United States)

    Dougherty, Paul J; Sherman, Don; Dau, Nathan; Bir, Cynthia

    2011-11-01

    Two mechanisms of injury, the temporary cavity and the sonic wave, have been proposed to produce indirect fractures as a projectile passes nearby in tissue. The purpose of this study is to evaluate the temporal relationship of pressure waves using strain gauge technology and high-speed video to elucidate whether the sonic wave, the temporary cavity, or both are responsible for the formation of indirect fractures. Twenty-eight fresh frozen cadaveric diaphyseal tibia (2) and femurs (26) were implanted into ordnance gelatin blocks. Shots were fired using 9- and 5.56-mm bullets traversing through the gelatin only, passing close to the edge of the bone, but not touching, to produce an indirect fracture. High-speed video of the impact event was collected at 20,000 frames/s. Acquisition of the strain data were synchronized with the video at 20,000 Hz. The exact time of fracture was determined by analyzing and comparing the strain gauge output and video. Twenty-eight shots were fired, 2 with 9-mm bullets and 26 with 5.56-mm bullets. Eight indirect fractures that occurred were of a simple (oblique or wedge) pattern. Comparison of the average distance of the projectile from the bone was 9.68 mm (range, 3-20 mm) for fractured specimens and 15.15 mm (range, 7-28 mm) for nonfractured specimens (Student's t test, p = 0.036). In this study, indirect fractures were produced after passage of the projectile. Thus, the temporary cavity, not the sonic wave, was responsible for the indirect fractures.

  4. Indirect Comorbidity in Childhood and Adolescence

    Directory of Open Access Journals (Sweden)

    William eCopeland

    2013-11-01

    Full Text Available Objective: Comorbidity between psychiatric disorders is common, but pairwise associations between two disorders may be explained by the presence of other diagnoses that are associated with both disorders or indirect comorbidity. Method: Comorbidities of common childhood psychiatric disorders were tested in three community samples of children ages 6 to 17 (8931 observations of 2965 subjects. Psychiatric disorder status in all three samples was assessed with the Child and Adolescent Psychiatric Assessment. Indirect comorbidity was defined as A-B associations that decreased from significance to nonsignificance after adjusting for other disorders. Results: All tested childhood psychiatric disorders were positively associated in bivariate analyses. After adjusting for comorbidities, many ssociations involving a behavioral disorder and an emotional disorder were attenuated suggesting indirect comorbidity. Generalized anxiety and depressive disorders displayed a very high level of overlap (adjusted OR=37.9. All analyses were rerun with depressive disorders grouped with generalized anxiety disorder in a single distress disorders category. In these revised models, all associations between and emotional disorder and a behavior disorder met our criteria for indirect comorbidity except for the association of oppositional defiant disorder with distress disorders (OR=11.3. Follow-up analyses suggested that the indirect associations were primarily accounted for by oppositional defiant disorder and the distress disorder category. There was little evidence of either sex differences or differences by developmental period Conclusions: After accounting for the overlap between depressive disorders with generalized anxiety disorder, direct comorbidity between emotional and behavioral disorders was uncommon. When there was evidence of indirect comorbidity, ODD and distress disorders were the key intermediary diagnoses accounting for the apparent associations.

  5. Indirect effects in dual radiation action

    International Nuclear Information System (INIS)

    Zaider, M.; Rossi, H.H.

    1988-01-01

    The basic aim in this paper is to establish the link between indirect effects of radiation action and the spatial distribution of radicals at the time of energy deposition as well as throughout subsequent diffusion and interaction. The fact that radicals diffuse for a finite distance before damaging a biomolecule has dramatic effects on their subsequent probability to result in lesions. Thus at very low DMSO concentrations, where p = 0.5, one expects - all other things being equal - some 75% of the lesions to result from indirect or semidirect lesions. The number calculated here is lower (15%), a direct result of the fact that such lesions involve proximity functions modulated by diffusion. At higher DMSO concentrations this percentage becomes progressively smaller, as expected. It appears thus that for low-LET radiation, the relative amount of indirect damage in single tracks (also termed intratrack or single events) action is very small. By contrast, intertrack (or two-event) contributions will have the ratio between direct and (indirect + semidirect) contributions given by p 2 /(1-p 2 ). The reason for this is that sublesions from different tracks are uniformly distributed throughout the cell nucleus; their probability of interaction should not depend on any previous diffusional processes. For the example given above (p = 0.5) they do expect 65% of intertrack (two-hit) lesions to have resulted from indirect or semidirect mechanisms. This contrast between the almost exclusively direct character of intratrack lesions and the dominant role of indirect action in intertrack lesions produced by low-LET radiation is an important conclusion of this study

  6. Global indirect aerosol effects: a review

    Directory of Open Access Journals (Sweden)

    U. Lohmann

    2005-01-01

    Full Text Available Aerosols affect the climate system by changing cloud characteristics in many ways. They act as cloud condensation and ice nuclei, they may inhibit freezing and they could have an influence on the hydrological cycle. While the cloud albedo enhancement (Twomey effect of warm clouds received most attention so far and traditionally is the only indirect aerosol forcing considered in transient climate simulations, here we discuss the multitude of effects. Different approaches how the climatic implications of these aerosol effects can be estimated globally as well as improvements that are needed in global climate models in order to better represent indirect aerosol effects are discussed in this paper.

  7. Biomass Indirect Liquefaction Strategy Workshop Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-07-01

    This report is based on the proceedings of the U.S. Department of Energy Bioenergy Technologies Office Biomass Indirect Liquefaction Strategy Workshop. The workshop, held March 20–21, 2014, in Golden, Colorado, discussed and detailed the research and development needs for biomass indirect liquefaction. Discussions focused on pathways that convert biomass-based syngas (or any carbon monoxide, hydrogen gaseous stream) to liquid intermediates (alcohols or acids) and further synthesize those intermediates to liquid hydrocarbons that are compatible as either a refinery feed or neat fuel.

  8. The power of indirect social ties

    OpenAIRE

    Zuo, Xiang; Blackburn, Jeremy; Kourtellis, Nicolas; Skvoretz, John; Iamnitchi, Adriana

    2014-01-01

    While direct social ties have been intensely studied in the context of computer-mediated social networks, indirect ties (e.g., friends of friends) have seen little attention. Yet in real life, we often rely on friends of our friends for recommendations (of good doctors, good schools, or good babysitters), for introduction to a new job opportunity, and for many other occasional needs. In this work we attempt to 1) quantify the strength of indirect social ties, 2) validate it, and 3) empiricall...

  9. Indirect methods for wake potential integration

    International Nuclear Information System (INIS)

    Zagorodnov, I.

    2006-05-01

    The development of the modern accelerator and free-electron laser projects requires to consider wake fields of very short bunches in arbitrary three dimensional structures. To obtain the wake numerically by direct integration is difficult, since it takes a long time for the scattered fields to catch up to the bunch. On the other hand no general algorithm for indirect wake field integration is available in the literature so far. In this paper we review the know indirect methods to compute wake potentials in rotationally symmetric and cavity-like three dimensional structures. For arbitrary three dimensional geometries we introduce several new techniques and test them numerically. (Orig.)

  10. Direct calorimetry of free-moving eels with manipulated thyroid status

    Science.gov (United States)

    van Ginneken, Vincent; Ballieux, Bart; Antonissen, Erik; van der Linden, Rob; Gluvers, Ab; van den Thillart, Guido

    2007-02-01

    In birds and mammals, the thyroid gland secretes the iodothyronine hormones of which tetraiodothyronine (T4) is less active than triiodothyronine (T3). The action of T3 and T4 is calorigenic and is involved in the control of metabolic rate. Across all vertebrates, thyroid hormones also play a major role in differentiation, development and growth. Although the fish thyroidal system has been researched extensively, its role in thermogenesis is unclear. In this study, we measured overall heat production to an accuracy of 0.1 mW by direct calorimetry in a free-moving European eel ( Anguilla anguilla L.) with different thyroid status. Hyperthyroidism was induced by injection of T3 and T4, and hypothyroidism was induced with phenylthiourea. The results show for the first time at the organismal level, using direct calorimetry, that neither overall heat production nor overall oxygen consumption in eels is affected by hyperthyroidism. Therefore, we conclude that the thermogenic metabolism-stimulating effect of thyroid hormones (TH) is not present with a cold-blooded fish species like the European eel. This supports the concept that TH does not stimulate thermogenesis in poikilothermic species.

  11. Titration calorimetry of surfactant–drug interactions: Micelle formation and saturation studies

    International Nuclear Information System (INIS)

    Waters, Laura J.; Hussain, Talib; Parkes, Gareth M.B.

    2012-01-01

    Highlights: ► Isothermal titration calorimetry can be used to monitor the saturation of micelles with pharmaceutical compounds. ► The number of drug molecules per micelle varies depending on the drug used and the temperature of the calorimeter. ► The change in enthalpy for the saturation of micelles with drugs can be endothermic or exothermic. ► The critical micellar concentration of an anionic surfactant (SDS) does not appear to vary in the presence of drugs. - Abstract: Isothermal titration calorimetry (ITC) was employed to monitor the addition of five model drugs to anionic surfactant based micelles, composed of sodium dodecyl sulfate (SDS), through to the point at which they were saturated with drug. Analysis of the resultant data using this newly developed method has confirmed the suitability of the technique to acquire such data with saturation limits established in all cases. Values for the point at which saturation occurred ranged from 17 molecules of theophylline per micelle at T = 298 K up to 63 molecules of caffeine per micelle at 310 K. Micellar systems can be disrupted by the presence of additional chemicals, such as the drugs used in this study, therefore a separate investigation was undertaken to determine the critical micellar concentration (CMC) for SDS in the presence of each drug at T = 298 K and 310 K using ITC. In the majority of cases, there was no appreciable alteration to the CMC of SDS with drug present.

  12. Kinetics of enzymatic high-solid hydrolysis of lignocellulosic biomass studied by calorimetry.

    Science.gov (United States)

    Olsen, Søren N; Lumby, Erik; McFarland, Kc; Borch, Kim; Westh, Peter

    2011-03-01

    Enzymatic hydrolysis of high-solid biomass (>10% w/w dry mass) has become increasingly important as a key step in the production of second-generation bioethanol. To this end, development of quantitative real-time assays is desirable both for empirical optimization and for detailed kinetic analysis. In the current work, we have investigated the application of isothermal calorimetry to study the kinetics of enzymatic hydrolysis of two substrates (pretreated corn stover and Avicel) at high-solid contents (up to 29% w/w). It was found that the calorimetric heat flow provided a true measure of the hydrolysis rate with a detection limit of about 500 pmol glucose s(-1). Hence, calorimetry is shown to be a highly sensitive real-time method, applicable for high solids, and independent on the complexity of the substrate. Dose-response experiments with a typical cellulase cocktail enabled a multidimensional analysis of the interrelationships of enzyme load and the rate, time, and extent of the reaction. The results suggest that the hydrolysis rate of pretreated corn stover is limited initially by available attack points on the substrate surface (conversion) but becomes proportional to enzyme dosage (excess of attack points) at later stages (>10% conversion). This kinetic profile is interpreted as an increase in polymer end concentration (substrate for CBH) as the hydrolysis progresses, probably due to EG activity in the enzyme cocktail. Finally, irreversible enzyme inactivation did not appear to be the source of reduced hydrolysis rate over time.

  13. Study of gamma irradiated polyethylenes by temperature modulated differential scanning calorimetry

    International Nuclear Information System (INIS)

    Secerov, B.; Galovic, S.; Trifunovic, S.; Milicevic, D.; Suljovrujic, E.

    2011-01-01

    Complete text of publication follows. The various polyethylenes (PEs) and effects of high energy radiation on theirs structures were widely studied in the past using conventional Differential Scanning Calorimetry (DSC) measurements. In this work, we applied the Temperature Modulated Differential Scanning Calorimetry (TMDSC) technique in order to obtain more information about the influence of initial structural differences and gamma radiation on the evolution in structure and thermal properties of different polyethylenes. For this reason, low density polyethylene (LDPE), linear low density polyethylene (LLDPE) and high density polyethylene (HDPE) samples were exposed to gamma radiation, in air, to a wide range of absorbed doses (up to 2400 kGy). The separation of the total heat flow TMDSC signal into a reversing and nonreversing part enabled to observed the low temperature enthalpy relaxation (related to the existence of the 'rigid amorphous phase') and recrystallization processes as well as to follow their and/or radiation-induced evolution of melting in a more revealing manner compared to the case of the conventional DSC. Consequently, our results indicate that TMDSC could improve the understanding of radiation-induced effects in polymers.

  14. A study of gamma-irradiated polyethylenes by temperature modulated differential scanning calorimetry

    Science.gov (United States)

    Galovic, S.; Secerov, B.; Trifunovic, S.; Milicevic, D.; Suljovrujic, E.

    2012-09-01

    Various polyethylenes (PEs) and the effects of high-energy radiation on their structures were widely studied in the past using conventional Differential Scanning Calorimetry (DSC) measurements. In this work, we used the Temperature Modulated Differential Scanning Calorimetry (TMDSC) technique in order to obtain more information about the influence of the initial structural differences and gamma radiation on the evolution in structure and thermal properties of different polyethylenes. For this reason, low density polyethylene (LDPE), linear low density polyethylene (LLDPE) and high density polyethylene (HDPE) samples were exposed to gamma radiation, in air, to a wide range of absorbed doses (up to 2400 kGy). The separation of the total heat flow TMDSC signal into a reversing and non-reversing part enabled us to observe the low-temperature enthalpy relaxation (related to the existence of the "rigid amorphous phase") and recrystallisation processes, as well as to follow their radiation-induced evolution and/or that of melting in a more revealing manner compared to the case of the conventional DSC. Consequently, our results indicate that TMDSC could improve the understanding of radiation-induced effects in polymers.

  15. Thermal behavior and phase identification of Valsartan by standard and temperature-modulated differential scanning calorimetry.

    Science.gov (United States)

    Skotnicki, Marcin; Gaweł, Agnieszka; Cebe, Peggy; Pyda, Marek

    2013-10-01

    Thermal behavior of angiotensin II type 1 (AT1) receptor antagonist, Valsartan (VAL), was examined employing thermogravimetric analysis (TGA), standard differential scanning calorimetry (DSC) and temperature-modulated differential scanning calorimetry (TMDSC). The stability of VAL was measured by TGA from 25 to 600°C. Decomposition of Valsartan starts around 160°C. The DSC curve shows two endotherms, occurring around 80°C and 100°C, related to evaporation of water and enthalpy relaxation, respectively. Valsartan was identified by DSC as an amorphous material and it was confirmed by X-ray powder diffraction. The glass transition of fresh Valsartan appears around 76°C (fictive temperature). TMDSC allows separation of the total heat flow rate into reversing and nonreversing parts. The nonreversing curve corresponds to the enthalpy relaxation and the reversing curve shows changes of heat capacity around 94°C. In the second run, TMDSC curve shows the glass transition process occurring at around 74°C. Results from standard DSC and TMDSC of Valsartan were compared over the whole range of temperature.

  16. The heat capacity of polyethylene fibers measured by multi-frequency temperature-modulated calorimetry

    International Nuclear Information System (INIS)

    Pyda, M.; Nowak-Pyda, E.; Wunderlich, B.

    2006-01-01

    The apparent heat capacity of polyethylene fibers in the melting region was measured by quasi-isothermal, temperature-modulated differential scanning calorimetry (TMDSC) and compared with results from standard differential scanning calorimetry (DSC) and the solid and liquid thermodynamic heat capacity as references from the ATHAS Data Bank. Using a multi-frequency, complex sawtooth modulation in the quasi-isothermal mode disclosed for the first time that the uncorrected apparent heat capacity C p =A Φ /(A T s ω) of the liquid polyethylene fiber increases with increasing frequency (A Φ is the differential heat-flow rate and A T s is the sample temperature). The frequency-dependent heat capacity cannot be represented by the expression: C p =A Φ /(A T s νω)[1+(τνω) 2 ] 0.5 because of a negative τ 2 . The results were later confirmed by independent measurements on single sinusoidal quasi-isothermal TMDSC on the same material. The error is caused by shrinking of the fiber, which deforms the sample pan

  17. Chip calorimetry for evaluation of biofilm treatment with biocides, antibiotics, and biological agents.

    Science.gov (United States)

    Morais, Frida Mariana; Buchholz, Friederike; Maskow, Thomas

    2014-01-01

    Any growth or bioconversion in biofilms is accompanied by the release of heat. The heat (in J) is tightly related to the stoichiometry of the respective process via law of Hess, and the heat production rate (in W or J/s) is additionally related to the process kinetics. This heat and the heat production rate can nowadays be measured by modern calorimetry with extremely high sensitivity. Flow-through calorimetry allows the measurement of bioprocesses in biofilms in real time, without the need of invasive sample preparation and disturbing of biofilm processes. Furthermore, it can be applied for long-term measurements and is even applicable to turbid media. Chip or miniaturized calorimeters have the additional advantages of extremely short thermal equilibration times and the requirement of very small amounts of media and chemicals. The precision of flow-through chip calorimeters (about 3 mW/L) allows the detection of early stages of biofilm development (about 10(5) bacteria cm(-2)).

  18. A High-Throughput Biological Calorimetry Core: Steps to Startup, Run, and Maintain a Multiuser Facility.

    Science.gov (United States)

    Yennawar, Neela H; Fecko, Julia A; Showalter, Scott A; Bevilacqua, Philip C

    2016-01-01

    Many labs have conventional calorimeters where denaturation and binding experiments are setup and run one at a time. While these systems are highly informative to biopolymer folding and ligand interaction, they require considerable manual intervention for cleaning and setup. As such, the throughput for such setups is limited typically to a few runs a day. With a large number of experimental parameters to explore including different buffers, macromolecule concentrations, temperatures, ligands, mutants, controls, replicates, and instrument tests, the need for high-throughput automated calorimeters is on the rise. Lower sample volume requirements and reduced user intervention time compared to the manual instruments have improved turnover of calorimetry experiments in a high-throughput format where 25 or more runs can be conducted per day. The cost and efforts to maintain high-throughput equipment typically demands that these instruments be housed in a multiuser core facility. We describe here the steps taken to successfully start and run an automated biological calorimetry facility at Pennsylvania State University. Scientists from various departments at Penn State including Chemistry, Biochemistry and Molecular Biology, Bioengineering, Biology, Food Science, and Chemical Engineering are benefiting from this core facility. Samples studied include proteins, nucleic acids, sugars, lipids, synthetic polymers, small molecules, natural products, and virus capsids. This facility has led to higher throughput of data, which has been leveraged into grant support, attracting new faculty hire and has led to some exciting publications. © 2016 Elsevier Inc. All rights reserved.

  19. Applications of isothermal titration calorimetry - the research and technical developments from 2011 to 2015.

    Science.gov (United States)

    Falconer, Robert J

    2016-10-01

    Isothermal titration calorimetry is a widely used biophysical technique for studying the formation or dissociation of molecular complexes. Over the last 5 years, much work has been published on the interpretation of isothermal titration calorimetry (ITC) data for single binding and multiple binding sites. As over 80% of ITC papers are on macromolecules of biological origin, this interpretation is challenging. Some researchers have attempted to link the thermodynamics constants to events at the molecular level. This review highlights work carried out using binding sites characterized using x-ray crystallography techniques that allow speculation about individual bond formation and the displacement of individual water molecules during ligand binding and link these events to the thermodynamic constants for binding. The review also considers research conducted with synthetic binding partners where specific binding events like anion-π and π-π interactions were studied. The revival of assays that enable both thermodynamic and kinetic information to be collected from ITC data is highlighted. Lastly, published criticism of ITC research from a physical chemistry perspective is appraised and practical advice provided for researchers unfamiliar with thermodynamics and its interpretation. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  20. Thermochemistry of some binary lead and transition metal compounds by high temperature direct synthesis calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Meschel, S.V., E-mail: meschel@jfi.uchicago.edu [Illinois Institute of Technology,Thermal Processing Technology Center, 10 W. 32nd Street, Chicago, Illinois 60615 (United States); Gordon Center for Integrated Science, 929 E. 57th Street, Chicago, Illinois 60637 (United States); Nash, P. [Illinois Institute of Technology,Thermal Processing Technology Center, 10 W. 32nd Street, Chicago, Illinois 60615 (United States); Chen, X.Q.; Wei, P. [Materials processing Modeling Division, Shenyang National Laboratory for Materials Science, Institute of Metals Research, 72 Wenhua Road, Shenyang City (China)

    2015-06-05

    Highlights: • Studied binary lead-transition metal alloys by high temperature calorimetry. • Determined the enthalpies of formation of 8 alloys. • Compared the measurements with predictions by the model of Miedema and by the ab initio method. - Abstract: The standard enthalpies of formation of some binary lead and transition metal compounds have been measured by high temperature direct synthesis calorimetry. The reported results are: Pb{sub 3}Sc{sub 5}(−61.3 ± 2.9); PbTi{sub 4}(−16.6 ± 2.4); Pb{sub 3}Y{sub 5}(−64.8 ± 3.6); Pb{sub 3}Zr{sub 5}(−50.6 ± 3.1); PbNb{sub 3}(−10.4 ± 3.4); PbRh(−16.5 ± 3.3); PbPd{sub 3}(−29.6 ± 3.1); PbPt(−34.7 ± 3.3) kJ/mole of atoms. We will compare our results with previously published measurements. We will also compare the experimental measurements with enthalpies of formation of transition metal compounds with elements in the same vertical column in the periodic table. We will compare our measurements with predicted values on the basis of the semi empirical model of Miedema and coworkers and with ab initio values when available.

  1. Thin-film calorimetry. In-situ characterization of materials for lithium-ion batteries

    Energy Technology Data Exchange (ETDEWEB)

    Omelcenko, Alexander; Wulfmeier, Hendrik; Albrecht, Daniel; Fritze, Holger [Clausthal Univ. of Technology, Goslar (Germany). Inst. of Energy Research and Physical Technologies; El Mofid, Wassima; Ivanov, Svetlozar; Bund, Andreas [Ilmenau Univ. of Technology (Germany). Dept. of Electrochemistry

    2017-11-15

    Thin-film calorimetry allows for qualitative and quantitative in-situ analysis of thermodynamic properties of thin films and thin-film systems from room temperature up to 1000 C. It is based on highly sensitive piezoelectric langasite resonators which serve simultaneously as planar temperature sensors and substrates for the films of interest. Generation or consumption of heat during phase transformations of the films cause deviations from the regular course of the resonance frequency. Thermodynamic data such as phase transformation temperatures and enthalpies are extracted from these deviations. Thin-film calorimetry on Sn and Al thin films is performed to prove the concept. The results demonstrate high reproducibility of the measurement approach and are in agreement with literature data obtained by established calorimetric techniques. The calibration of the system is done in different atmospheres by application of defined heat pulses via heating structures. The latter replace the films of interest and simulate phase transformations to provide detailed analysis of the heat transfer mechanisms occurring in the measurement system. Based on this analysis, a data evaluation concept is developed. Application-relevant studies are performed on thin films of the lithium-ion battery materials NMC(A), NCA, LMO, and MoS{sub 2}. Their phase transformation temperatures and enthalpies are evaluated in oxidizing and reducing atmospheres. Furthermore, their thermodynamic stability ranges are presented. Finally, measurements on all-solid-state thin-film batteries during electrochemical cycling are performed. They demonstrate the suitability of the system for in-situ investigations.

  2. Methodology of hot nucleus calorimetry and thermometry produced by nuclear reactions around Fermi energies; Methodologie de la calorimetrie et de la thermometrie des noyaux chauds formes lors de collisions nucleaires aux energies de Fermi

    Energy Technology Data Exchange (ETDEWEB)

    Vient, E

    2006-12-15

    This work deals with the calorimetry and thermometry of hot nuclei produced in collisions Xe + Sn between 25 and 100 MeV/u. The apparatus for hot nucleus physical characterization is the 4{pi} detector array Indra. This study was made by using the event generators Gemini, Simon and Hipse and a data-processing filter simulating the complete operation of the multi-detector. The first chapter presents the different ways of producing hot nuclei. In the second and third chapters, the author presents a critical methodological study of calorimetry and thermometry applied to hot nuclei, different methods are reviewed, their accuracy and application range are assessed. All the calorimetry methods rely on the assumption that we are able to discriminate decay products of the hot nucleus from evaporated particles. In the fourth chapter, the author gives some ways of improving calorimetry characterization of the hot nucleus. An alternative method of calorimetry is proposed in the fifth chapter, this method is based on the experimental determination of an evaporation probability that is deduced from the physical characteristics of the particles present in a restricted domain of the space of velocities.

  3. Development of an indirect spectrophotometric method for ...

    African Journals Online (AJOL)

    A simple and rapid indirect spectrophotometric method for determination of ... of the colored product was measured at 405 nm and pH 3 against a reagent blank. ... The limit of detection and quantification were found to be 0.20±0.03 and ...

  4. Indirect processes in electron-ion scattering

    International Nuclear Information System (INIS)

    Bottcher, C.; Griffin, D.C.; Pindzola, M.S.; Phaneuf, R.A.

    1983-10-01

    A summary is given of an informal workshop held at Oak Ridge National Laboratory on June 22-23, 1983, in which the current status of theoretical calculations of indirect processes in electron-ion scattering was reviewed. Processes of particular interest in astrophysical and fusion plasmas were emphasized. Topics discussed include atomic structure effects, electron-impact ionization, and dielectronic recombination

  5. Indirect effects of recreation on wildlife

    Science.gov (United States)

    David N. Cole; Peter B. Landres

    1995-01-01

    Most of this book focuses on direct impacts to wildlife that result from contact with people. The purpose of our chapter is to provide a broad overview of the indirect influences that recreation has on wildlife. Recreational activities can change the habitat of an animal. This, in turn, affects the behavior, survival, reproduction, and distribution of individuals....

  6. 46 CFR 154.1720 - Indirect refrigeration.

    Science.gov (United States)

    2010-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Special Design and Operating Requirements § 154.1720 Indirect refrigeration. A refrigeration system that is used to cool acetaldehyde, ethylene...

  7. Indirect processes in electron-ion scattering

    Energy Technology Data Exchange (ETDEWEB)

    Bottcher, C.; Griffin, D.C.; Pindzola, M.S.; Phaneuf, R.A.

    1983-10-01

    A summary is given of an informal workshop held at Oak Ridge National Laboratory on June 22-23, 1983, in which the current status of theoretical calculations of indirect processes in electron-ion scattering was reviewed. Processes of particular interest in astrophysical and fusion plasmas were emphasized. Topics discussed include atomic structure effects, electron-impact ionization, and dielectronic recombination.

  8. 27 CFR 6.32 - Indirect interest.

    Science.gov (United States)

    2010-04-01

    ... OF THE TREASURY LIQUORS âTIED-HOUSEâ Unlawful Inducements Interest in Retail Property § 6.32 Indirect interest. Industry member interest in retail property includes any interest acquired by corporate officials, partners, employees or other representatives of the industry member. Any interest in retail property...

  9. 27 CFR 6.26 - Indirect interest.

    Science.gov (United States)

    2010-04-01

    ... OF THE TREASURY LIQUORS âTIED-HOUSEâ Unlawful Inducements Interest in Retail License § 6.26 Indirect interest. Industry member interest in retail licenses includes any interest acquired by corporate officials, partners, employees or other representatives of the industry member. Any interest in a retail license...

  10. Indirect Costs: Daily Bread, Cake, or Cracker.

    Science.gov (United States)

    Lucas, Robert A.

    1988-01-01

    The tradition of negotiating indirect costs in grants should be abandoned, and research administrators should instead offer different levels of service depending on what the sponsor wants to spend. Three levels of overhead rate are suggested (super, regular, and economy) and their corresponding levels of service are defined. (MSE)

  11. Epidemic spreading through direct and indirect interactions.

    Science.gov (United States)

    Ganguly, Niloy; Krueger, Tyll; Mukherjee, Animesh; Saha, Sudipta

    2014-09-01

    In this paper we study the susceptible-infected-susceptible epidemic dynamics, considering a specialized setting where popular places (termed passive entities) are visited by agents (termed active entities). We consider two types of spreading dynamics: direct spreading, where the active entities infect each other while visiting the passive entities, and indirect spreading, where the passive entities act as carriers and the infection is spread via them. We investigate in particular the effect of selection strategy, i.e., the way passive entities are chosen, in the spread of epidemics. We introduce a mathematical framework to study the effect of an arbitrary selection strategy and derive formulas for prevalence, extinction probabilities, and epidemic thresholds for both indirect and direct spreading. We also obtain a very simple relationship between the extinction probability and the prevalence. We pay special attention to preferential selection and derive exact formulas. The analysis reveals that an increase in the diversity in the selection process lowers the epidemic thresholds. Comparing the direct and indirect spreading, we identify regions in the parameter space where the prevalence of the indirect spreading is higher than the direct one.

  12. Indirect Determination of the sigma - omega

    DEFF Research Database (Denmark)

    Ulfkjær, J. P.; Brincker, Rune

    . The beams where submitted to three-point bending in a servo-controlled materials testing system. The constitutive parameters in the fictitious crack model were determined by using three different indirect techniques, which are described and evaluated. The results show that the fracture energy is increasing...

  13. Comprehension Process of Second Language Indirect Requests.

    Science.gov (United States)

    Takahashi, Satomi; Roitblat, Herbert L.

    1994-01-01

    Examines the comprehension of English conventional indirect requests by native English speakers and Japanese learners of English. Subjects read stories inducing either a conventional or a literal interpretation of a priming sentence. Results suggest that both native and nonnative speakers process both meanings of an ambiguous conventional request.…

  14. 48 CFR 31.203 - Indirect costs.

    Science.gov (United States)

    2010-10-01

    ... fiscal year used for financial reporting purposes in accordance with generally accepted accounting... contract or other work, indirect costs are those remaining to be allocated to intermediate or two or more... basis of the benefits accruing to intermediate and final cost objectives. When substantially the same...

  15. Scene independent real-time indirect illumination

    DEFF Research Database (Denmark)

    Frisvad, Jeppe Revall; Christensen, Niels Jørgen; Falster, Peter

    2005-01-01

    A novel method for real-time simulation of indirect illumination is presented in this paper. The method, which we call Direct Radiance Mapping (DRM), is based on basal radiance calculations and does not impose any restrictions on scene geometry or dynamics. This makes the method tractable for rea...

  16. APACHE II SCORING SYSTEM AND ITS MODIFICATION FOR THE ASSESSMENT OF DISEASE SEVERITY IN CHILDREN WHO UNDERWENT POLYCHEMOTHERAPY

    Directory of Open Access Journals (Sweden)

    А. V. Sotnikov

    2014-01-01

    Full Text Available Short-term disease prognosis should be considered for the appropriate treatment policy based on the assessment of disease severity in patients with acute disease. The adequate assessment of disease severity and prognosis allows the indications for transferring patients to the resuscitation and intensive care department to be defined more precisely. Disease severity of patients who underwent polychemotherapy was assessed using APACHE II scoring system.

  17. Two distinct neural mechanisms underlying indirect reciprocity.

    Science.gov (United States)

    Watanabe, Takamitsu; Takezawa, Masanori; Nakawake, Yo; Kunimatsu, Akira; Yamasue, Hidenori; Nakamura, Mitsuhiro; Miyashita, Yasushi; Masuda, Naoki

    2014-03-18

    Cooperation is a hallmark of human society. Humans often cooperate with strangers even if they will not meet each other again. This so-called indirect reciprocity enables large-scale cooperation among nonkin and can occur based on a reputation mechanism or as a succession of pay-it-forward behavior. Here, we provide the functional and anatomical neural evidence for two distinct mechanisms governing the two types of indirect reciprocity. Cooperation occurring as reputation-based reciprocity specifically recruited the precuneus, a region associated with self-centered cognition. During such cooperative behavior, the precuneus was functionally connected with the caudate, a region linking rewards to behavior. Furthermore, the precuneus of a cooperative subject had a strong resting-state functional connectivity (rsFC) with the caudate and a large gray matter volume. In contrast, pay-it-forward reciprocity recruited the anterior insula (AI), a brain region associated with affective empathy. The AI was functionally connected with the caudate during cooperation occurring as pay-it-forward reciprocity, and its gray matter volume and rsFC with the caudate predicted the tendency of such cooperation. The revealed difference is consistent with the existing results of evolutionary game theory: although reputation-based indirect reciprocity robustly evolves as a self-interested behavior in theory, pay-it-forward indirect reciprocity does not on its own. The present study provides neural mechanisms underlying indirect reciprocity and suggests that pay-it-forward reciprocity may not occur as myopic profit maximization but elicit emotional rewards.

  18. The Demographics of Patients with Skin Cancer who Underwent Surgery in Diyarbakır and Performed Surgical Techniques

    Directory of Open Access Journals (Sweden)

    Burhan Özalp

    2018-06-01

    Full Text Available Objective: The major factor for developing malignant skin cancers is sunlight exposure. This study aimed to evaluate the demographics of patients with skin cancers who underwent surgery in Diyarbakır where the population is exposed to more sunlight than most other Turkish cities. Methods: The medical records of patients who underwent surgery for malignant skin cancer excision between 2011 and 2016 were searched using University Hospital’s patient database program. Data about patients’ demographics, cancer features, and the surgical techniques performed were collected. Results: Over a 5-year period, 190 patients underwent surgical excision. The male to female ratio was 1.56, and the mean age was 65.8 ± 15.7 (range, 20-94 years. The most common skin cancer was basal cell carcinoma (n=138, 72.7%, followed by squamous cell carcinoma (n=45, 23.7% and malignant melanoma (n=5, 2.6%. The most common surgery was primary excision, which was performed in 90 of 190 patients (47.36%; tissue reconstruction with a skin graft or flap surgery was required for the remaining 100 (52.63%, showing a significant difference (p<0.001. Conclusion: Basal cell carcinoma is the most common skin cancer, and less than half of the patients sought treatment immediately after they recognized the lesion. The public should be educated about skin cancers to increase early diagnosis and encourage timely treatment, thereby decreasing morbidity and mortality from skin cancer.

  19. Microdose flare-up vs. flexible-multidose GnRH antagonist protocols for poor responder patients who underwent ICSI.

    Science.gov (United States)

    Esinler, I

    2014-01-01

    To compare the performance of microdose flare-up (MF) and flexible-multidose gonadotropin-releasing hormone (GnRH) antagonist protocols in poor responder patients who underwent intracytoplasmic sperm injection (ICSI). One hundred and 12 consecutive patients (217 cycles) suspected to have poor ovarian response were enrolled. Group 1 (MF GnRH agonist group) constituted 64 patients (135 cycles) who underwent MF GnRH agonist protocol. Group 2 (flexible-multidose GnRH antagonist group) constituted 48 patients (82 cycles) who underwent flexible-multidose GnRH antagonist protocol. The duration of stimulation (d) (11.5 +/- 2.1 vs. 10.4 +/- 2.7, p or = seven blastomeres and < 10% fragmentation at day 3 (35.9% vs. 65.1%, p < 0.05) were significantly lower in Group 1 when compared to Group 2. The number of embryos transferred (2.2 +/- 1.3 vs. 2.4 +/- 0.9), the clinical pregnancy per embryo transfer (16.3% vs. 25.8%), and the implantation rate (8.6% vs. 12.2%) were comparable between groups. Although the flexible-multidose GnRH antagonist protocol produced better oocyte and embryo parameters, the clinical pregnancy rate and the implantation rates were comparable between the flexible-multidose GnRH antagonist and MF protocols in poor responder patients.

  20. Heat capacity and transition behavior of sucrose by standard, fast scanning and temperature-modulated calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Magoń, A. [Department of Chemistry, University of Technology, 35-959 Rzeszów (Poland); Wurm, A.; Schick, C. [Department of Physics, University of Rostock, 18057 Rostock (Germany); Pangloli, Ph.; Zivanovic, S. [Department of Food Science and Technology, University of Tennessee, Knoxville, TN 37996 (United States); Skotnicki, M. [Department of Pharmaceutical Technology, Poznan University of Medical Sciences, 60-780 Poznań (Poland); Pyda, M., E-mail: mpyda@utk.edu [Department of Chemistry, University of Technology, 35-959 Rzeszów (Poland)

    2014-08-10

    Highlights: • Experimental, apparent heat capacity of sucrose was investigated by advanced thermal analysis. • Vibrational heat capacity of solid state was linked with a low temperature experimental heat capacity of sucrose. • Equilibrium melting parameters of sucrose were determined. • Decomposition, superheating of crystalline sucrose during melting process were presented. • TGA, DSC, TMDSC, and FSC are useful tools for characterization of sucrose. - Abstract: The heat capacity (C{sub p}) of crystalline and amorphous sucrose was determined using standard and quasi-isothermal temperature modulated differential scanning calorimetry. The results were combined with the published data determined by adiabatic calorimetry, and the C{sub p} values are now reported for the wide 5–600 K range. The experimental C{sub p} of solid sucrose at 5–300 K was used to calculate the vibrational, solid C{sub p} based on the vibrational molecular motions. The calculated solid and liquid C{sub p} together with the transition parameters for equilibrium conditions were used as references for detailed quantitative thermal analysis of crystalline and amorphous sucrose. Melting temperature (T{sub m}) of the crystalline sucrose was identified in a broad 442–465 K range with a heat of fusion of 40–46 J/mol determined at heating rates 0.5–20 K/min, respectively. The equilibrium T{sub m} and heat of fusion of crystalline sucrose were estimated at zero heating rate as T{sup o}{sub m} = 424.4 K and ΔH{sup o}{sub f} = 32 kJ/mol, respectively. The glass transition temperature (T{sub g}) of amorphous sucrose was at 331 K with a change in C{sub p} of 267 J/(mol K) as it was estimated from reversing heat capacity by quasi-isothermal TMDSC on cooling. At heating rates less than 30 K/min, thermal decomposition occurred during melting, while at extreme rate of 1000 K/s, degradation was not observed. Data obtained by fast scanning calorimetry (FSC) at 1000 K/s, showed that T{sub m} was

  1. INDIRECT LABOR COSTS AND IMPLICATIONS FOR OVERHEAD ALLOCATION

    OpenAIRE

    Bea Chiang

    2013-01-01

    Cost accounting typically allocates indirect labor cost to cost object based on direct labor hours. The allocation process implicitly assumes that indirect labor costs vary proportionally with direct labor hours. The assumption of a linear relationship between indirect and direct labor is particularly suspicious at low production volume levels because there tends to be a fixed component in indirect labor. The linearity assumption is also challenged by recent increasing complexity of indirect ...

  2. The Indirect cost of illness in Africa

    Directory of Open Access Journals (Sweden)

    Joses Muthuri Kirigia

    2018-06-01

    Full Text Available Background: The current study estimated (a the indirect costs associated with non-fatal disability and premature death across a wide range of diseases and health conditions in Africa in 2015 and (b the potential savings that could be accrued if countries were to meet the 3 health targets of the substainable development goal (SDG compared to the costs under the status quo. Methods: This study used the lost output or human capital approach to quantify the gross domestic product (GDP losses associated with the disability-adjusted-life-years (DALYs lost due to all causes by age group as well as by country economic classification (Group 1: 10 high/upper-middle income countries; Group 2: 17 lower-middle income countries; and Group 3: 27 low income countries. Results: The expected indirect cost of the 704,765,879 DALYs lost in Africa in 2015 was Int$ 2,983,187,560,197. Of this amount, 25.17%, 57.84% and 16.99% were incurred by the economies of the countries comprising Group 1, Group 2 and Group 3, respectively. Of the total continental indirect cost, 36.9%, 10.5%, 13.7%, 17.0%, 7.6%, 6.8% and 7.5% were associated with people aged 0-4, 5-14, 15-29, 30-49, 50-59, 60-69 and 70 years or older, respectively. Most of the total indirect cost (56.61% was attributable to maternal conditions, AIDS, tuberculosis (TB, malaria, neglected tropicald diseases (NTDs, non-communicable diseases and traffic injuries. Approximately half (47% of this cost could be avoided (or saved every year if the 3 (health targets of the SDG were fully met. Conclusion: The study estimated the total indirect cost of illness due to all causes by age group and country economic classification. The annual indirect cost is substantial. The findings contained in this paper suggest that health system strengthening should focus on both rich and poor countries, people of all ages and specific disease categories.

  3. Cruel intentions on television and in real life: can viewing indirect aggression increase viewers' subsequent indirect aggression?

    Science.gov (United States)

    Coyne, Sarah M; Archer, John; Eslea, Mike

    2004-07-01

    Numerous studies have shown that viewing violence in the media can influence an individual's subsequent aggression, but none have examined the effect of viewing indirect aggression. This study examines the immediate effect of viewing indirect and direct aggression on subsequent indirect aggression among 199 children ages 11 to 14 years. They were shown an indirect, direct, or no-aggression video and their subsequent indirect aggression was measured by negative evaluation of a confederate and responses to a vignette. Participants viewing indirect or direct aggression gave a more negative evaluation of and less money to a confederate than participants viewing no-aggression. Participants viewing indirect aggression gave less money to the confederate than those viewing direct aggression. Participants viewing indirect aggression gave more indirectly aggressive responses to an ambiguous situation and participants viewing direct aggression gave more directly aggressive responses. This study provides the first evidence that viewing indirect aggression in the media can have an immediate impact on subsequent aggression.

  4. Dual-Readout Calorimetry for High-Quality Energy Measurements. Final Report

    International Nuclear Information System (INIS)

    Wigmans, Richard; Nural, Akchurin

    2013-01-01

    This document constitutes the final report on the project Dual-Readout Calorimetry for High-Quality Energy Measurements. The project was carried out by a consortium of US and Italian physicists, led by Dr. Richard Wigmans (Texas tech University). This consortium built several particle detectors and tested these at the European Center for Nuclear Research (CERN) in Geneva, Switzerland. The idea arose to use scintillating crystals as dual-readout calorimeters. Such crystals were of course already known to provide excellent energy resolution for the detection of particles developing electromagnetic (em) showers. The efforts to separate the signals from scintillating crystals into scintillation and Cerenkov components led to four different methods by which this could be accomplished. These methods are based on a) the directionality, b) spectral differences, c) the time structure, and d) the polarization of the signals

  5. Effect of temperature on studtite stability: Thermogravimetry and differential scanning calorimetry investigations

    International Nuclear Information System (INIS)

    Rey, A.; Casas, I.; Gimenez, J.; Quinones, J.; Pablo, J. de

    2009-01-01

    The main objective of this work is the study of the influence of temperature on the stability of the uranyl peroxide tetrahydrate (UO 2 O 2 . 4H 2 O) studtite, which may form on the spent nuclear fuel surface as a secondary solid phase. Preliminary results on the synthesis of studtite in the laboratory at different temperatures have shown that the solid phases formed when mixing hydrogen peroxide and uranyl nitrate depends on temperature. Studtite is obtained at 298 K, meta-studtite (UO 2 O 2 . 2H 2 O) at 373 K, and meta-schoepite (UO 3 . nH 2 O, with n 3 O 8 . By means of the differential scanning calorimetry the molar enthalpies of the transformations occurring at 403 and 504 K have been determined to be -42 ± 10 and -46 ± 2 kJ mol -1 , respectively

  6. Melting temperature and enthalpy variations of phase change materials (PCMs): a differential scanning calorimetry (DSC) analysis

    Science.gov (United States)

    Sun, Xiaoqin; Lee, Kyoung Ok; Medina, Mario A.; Chu, Youhong; Li, Chuanchang

    2018-06-01

    Differential scanning calorimetry (DSC) analysis is a standard thermal analysis technique used to determine the phase transition temperature, enthalpy, heat of fusion, specific heat and activation energy of phase change materials (PCMs). To determine the appropriate heating rate and sample mass, various DSC measurements were carried out using two kinds of PCMs, namely N-octadecane paraffin and calcium chloride hexahydrate. The variations in phase transition temperature, enthalpy, heat of fusion, specific heat and activation energy were observed within applicable heating rates and sample masses. It was found that the phase transition temperature range increased with increasing heating rate and sample mass; while the heat of fusion varied without any established pattern. The specific heat decreased with the increase of heating rate and sample mass. For accuracy purpose, it is recommended that for PCMs with high thermal conductivity (e.g. hydrated salt) the focus will be on heating rate rather than sample mass.

  7. Low-temperature transitions in cod and tuna determined by differential scanning calorimetry

    DEFF Research Database (Denmark)

    Jensen, Kristina Nedenskov; Jørgensen, Bo; Nielsen, Jette

    2003-01-01

    Differential scanning calorimetry measurements have revealed different thermal transitions in cod and tuna samples. Transition temperatures detected Lit -11degreesC, -15degreesC and -21degreesC were highly dependent on the annealing temperature. In tuna muscle an additional transition was observed...... at -72degreesC. This transition appeared differently than the thermal events observed at higher temperatures, as it spanned a broad temperature interval of 25degreesC. The transition was comparable to low-temperature glass transitions reported in protein-rich systems. No transition at this low...... temperature was detected in cod samples. The transitions observed at higher temperatures (-11degreesC to -21degreesC) may possibly stein from a glassy matrix containing muscle proteins. However, the presence of a glass transition at - 11degreesC was in disagreement with the low storage stability at -18degrees...

  8. Online Particle Detection by Neural Networks Based on Topologic Calorimetry Information

    CERN Document Server

    Ciodaro, T; The ATLAS collaboration; Damazio, D; de Seixas, JM

    2011-01-01

    This paper presents the last results from the Ringer algorithm, which is based on artificial neural networks for the electron identification at the online filtering system of the ATLAS particle detector, in the context of the LHC experiment at CERN. The algorithm performs topological feature extraction over the ATLAS calorimetry information (energy measurements). Later, the extracted information is presented to a neural network classifier. Studies showed that the Ringer algorithm achieves high detection efficiency, while keeping the false alarm rate low. Optimizations, guided by detailed analysis, reduced the algorithm execution time in 59%. Also, the payload necessary to store the Ringer algorithm information represents less than 6.2 percent of the total filtering system amount

  9. Design and first measurements of an alternative calorimetry chamber for the HZB quadrupole resonator

    CERN Document Server

    Keckert, Sebastian; Knobloch, Jens; Kugeler, Oliver

    2015-01-01

    The systematic research on superconducting thin films requires dedicated testing equipment. The Quadrupole Resonator (QPR) is a specialized tool to characterize the superconducting RF properties of circular planar samples. A calorimetric measurement of the RF surface losses allows the surface resistance to be measured with sub nano-ohm resolution. This measurement can be performed over a wide temperature and magnetic field range, at frequencies of 433, 866 and 1300 MHz. The system at Helmholtz-Zentrum Berlin (HZB) is based on a resonator built at CERN and has been optimized to lower peak electric fields and an improved resolution. In this paper the design of an alternative calorimetry chamber is presented, providing flat samples for coating which are easy changeable. All parts are connected by screwing connections and no electron beam welding is required. Furthermore this design enables exchangeability of samples between the resonators at HZB and CERN. First measurements with the new design show ambiguous r...

  10. Ln(III)-malate complexation studies using TRLFS and micro titration calorimetry

    International Nuclear Information System (INIS)

    Taube, F.; Drobot, B.; Acker, M.; Taut, S.; Stumpf, Thorsten

    2017-01-01

    The complexation of trivalent lanthanides was studied using Time-Resolved Laser-Induced Fluorescence Spectroscopy (TRLFS) and Isothermal Titration Calorimetry (ITC). Formation constants, complexation enthalpies and fluorescence lifetimes are determined over a wide pH range at I = 0.5 m NaCl. This subject has the following background: Concrete is widely used as engineering barrier and for waste conditioning in waste repositories. Its binding agent is cement. Organic cement additives, which are used to improve the workability of fresh concrete, are complexation agents for radionuclides after they have been released during the concretes degradation. Thus, these additives might have an impact on the aqueous geochemistry of actinides. Here, the α-hydroxydicarboxylic acid or malic acid is examined. It is used in water-reducers or retarders in cement.

  11. Ln(III)-malate complexation studies using TRLFS and micro titration calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Taube, F.; Drobot, B. [Technische Univ. Dresden (Germany). Professorship Radiochemistry; Acker, M.; Taut, S. [Technische Univ. Dresden (Germany). Central Radionuclide Laboratory; Stumpf, Thorsten [Helmholtz-Zentrum Dresden-Rossendorf e.V., Dresden (Germany). Inst. of Resource Ecology

    2017-06-01

    The complexation of trivalent lanthanides was studied using Time-Resolved Laser-Induced Fluorescence Spectroscopy (TRLFS) and Isothermal Titration Calorimetry (ITC). Formation constants, complexation enthalpies and fluorescence lifetimes are determined over a wide pH range at I = 0.5 m NaCl. This subject has the following background: Concrete is widely used as engineering barrier and for waste conditioning in waste repositories. Its binding agent is cement. Organic cement additives, which are used to improve the workability of fresh concrete, are complexation agents for radionuclides after they have been released during the concretes degradation. Thus, these additives might have an impact on the aqueous geochemistry of actinides. Here, the α-hydroxydicarboxylic acid or malic acid is examined. It is used in water-reducers or retarders in cement.

  12. A Differential Scanning Calorimetry Method for Construction of Continuous Cooling Transformation Diagram of Blast Furnace Slag

    Science.gov (United States)

    Gan, Lei; Zhang, Chunxia; Shangguan, Fangqin; Li, Xiuping

    2012-06-01

    The continuous cooling crystallization of a blast furnace slag was studied by the application of the differential scanning calorimetry (DSC) method. A kinetic model describing the correlation between the evolution of the degree of crystallization with time was obtained. Bulk cooling experiments of the molten slag coupled with numerical simulation of heat transfer were conducted to validate the results of the DSC methods. The degrees of crystallization of the samples from the bulk cooling experiments were estimated by means of the X-ray diffraction (XRD) and the DSC method. It was found that the results from the DSC cooling and bulk cooling experiments are in good agreement. The continuous cooling transformation (CCT) diagram of the blast furnace slag was constructed according to crystallization kinetic model and experimental data. The obtained CCT diagram characterizes with two crystallization noses at different temperature ranges.

  13. Exploring ultrastability in nanostructured glassy polymer films by fast-scanning calorimetry.

    Science.gov (United States)

    Chowdhury, Mithun; Wang, Yucheng; Jeong, Hyuncheol; Cangialosi, Daniele; Priestley, Rodney

    A decade ago ultra-stable small molecule glass formers were discovered. Since then a significant amount of research has been devoted to traverse down the energy landscape of such glass formers via physical vapor deposition (PVD). Matrix assisted pulsed laser evaporation (MAPLE) has the known ability to produce vapour deposited nanostructured polymer glass with exceptional kinetic stability. We explored the role of deposition temperature/ growth rate on thermodynamic and kinetic stabilities of poly (methyl methacrylate) (PMMA) films, deposited over a fast-scanning calorimetry sensor. We found in general any MAPLE deposited glass is kinetically more stable than bulk polymer and its spin-coated film. Moreover slow growth rate and optimum temperature during MAPLE deposition can additionally lead to thermodynamically stable (low-energy) glass. The role of interfaces formed through dramatic nanostructuring and packing of nanoglobules (removal of void space) may have additional role on such ultrastability. NSF-MRSEC through PCCM (Grant: DMR-1420541).

  14. Kinetics of Enzymatic High-Solid Hydrolysis of Lignocellulosic Biomass Studied by Calorimetry

    DEFF Research Database (Denmark)

    Olsen, Søren Nymand; Rasmussen, Erik Lumby; McFarland, K.C.

    2011-01-01

    analysis of the interrelationships of enzyme load and the rate, time, and extent of the reaction. The results suggest that the hydrolysis rate of pretreated corn stover is limited initially by available attack points on the substrate surface (conversion) but becomes proportional to enzyme dosage......Enzymatic hydrolysis of high-solid biomass (>10% w/w dry mass) has become increasingly important as a key step in the production of second-generation bioethanol. To this end, development of quantitative real-time assays is desirable both for empirical optimization and for detailed kinetic analysis...... rate with a detection limit of about 500 pmol glucose s−1. Hence, calorimetry is shown to be a highly sensitive real-time method, applicable for high solids, and independent on the complexity of the substrate. Dose–response experiments with a typical cellulase cocktail enabled a multidimensional...

  15. Determination of Energy Characteristic and Microporous Volume by Immersion Calorimetry in Carbon Monoliths

    Directory of Open Access Journals (Sweden)

    Juan Carlos Moreno-Piraján

    2012-01-01

    Full Text Available Activated carbon monoliths disc and honeycomb type were prepared by chemical activation of coconut shell with zinc chloride at different concentrations, without using a binder. The structures were characterized by N2 adsorption at 77 K and immersion calorimetry into benzene. The experimental results showed that the activation with zinc chloride produces a wide microporous development, with micropore volume between 0,38 and 0,79 cm3g-1, apparent BET surface area between 725 and 1523 m2g-1 and immersion enthalpy between 73,5 and 164,2 Jg-1. We compared the experimental enthalpy with calculated enthalpy by equation Stoeckli-Kraehenbuehl finding a data dispersion from which can infer that the structures are not purely microporous; this fact is ratified with similar behavior that the evidence t the product EoWo.

  16. Study and characterization of ammonium diuranate and uranium trioxide by thermogravimetry and differential scanning calorimetry

    International Nuclear Information System (INIS)

    Dantas, J.M.

    1983-01-01

    Thermogravimetry (TG), Differential Thermogravimetry (DTG) and Differential Scanning Calorimetry (DSC) were used to characterize the thermal behavior of ammonium diuranate (ADU) and uranium trioxide (UO 3 ) produced at IPEN'S Chemical Enginnering Department. Compounds characterization was done using the molar ratios among the compounds and the oxides resulting from thermal decomposition. The TG and DTG curves registered for each sample were used for the determination of the following temperatures: - temperature of water evolution (free and crystallized water); - ammonia evolution and oxidation temperature; - ocluded ammonium nitrate decomposition temperature and - oxygen release temperature. The intermediate phases and their thermal stabilities were also identified by TG and DTG and confirmed by DSC curves, DSC curves showed also the exothermic and endothermic behavior of the processes involved. Finally, the great amount of data collected in this study can be handed as a guide by the professionals responsible for the operation of ADU,UO 3 and UF 4 pilot plants. (Author) [pt

  17. Thermodynamic signature of secondary nano-emulsion formation by isothermal titration calorimetry.

    Science.gov (United States)

    Fotticchia, Iolanda; Fotticchia, Teresa; Mattia, Carlo Andrea; Netti, Paolo Antonio; Vecchione, Raffaele; Giancola, Concetta

    2014-12-09

    The stabilization of oil in water nano-emulsions by means of a polymer coating is extremely important; it prolongs the shelf life of the product and makes it suitable for a variety of applications ranging from nutraceutics to cosmetics and pharmaceutics. To date, an effective methodology to assess the best formulations in terms of thermodynamic stability has yet to be designed. Here, we perform a complete physicochemical characterization based on isothermal titration calorimetry (ITC) compared to conventional dynamic light scattering (DLS) to identify polymer concentration domains that are thermodynamically stable and to define the degree of stability through thermodynamic functions depending upon any relevant parameter affecting the stability itself, such as type of polymer coating, droplet distance, etc. For instance, the method was proven by measuring the energetics in the case of two different biopolymers, chitosan and poly-L-lysine, and for different concentrations of the emulsion coated with poly-L-lysine.

  18. Determination of ice content in hardened concrete by low-temperature calorimetry

    DEFF Research Database (Denmark)

    Wu, Min; Johannesson, Björn; Geiker, Mette Rica

    2014-01-01

    Low-temperature calorimetry has been used to determine the ice content in concrete at different temperatures when exposed to low-temperature environments. However, the analysis of the ice content from the measured data of heat flow is not straightforward. In this study, two important factors...... influencing the ice content calculation are discussed. The importance of the baseline determination for the calculation of the ice content is realized. Two different methods of generating the baseline are discussed. First, the ‘J-baseline’ is discussed which is a recently proposed extrapolation method based...... the ‘J-baseline’ method and the ‘C-baseline’ method can be used to calculate the approximate baseline. The heat of fusion of the water confined in small pores is another important parameter to be considered in ice content calculation. This property must be carefully analyzed in order to accurately...

  19. Study of phase changing characteristics of granular composites using differential scanning calorimetry

    International Nuclear Information System (INIS)

    Rady, Mohamed

    2009-01-01

    Characterization of the phase changing behavior of granular materials is an important issue for design and optimization of latent heat thermal energy storage (LHTES) systems. In the present work, differential scanning calorimetry (DSC) has been used to study the phase changing behavior of granular composites consisting of ceramic encapsulated phase change material (EPCM) with particle diameters of 1-3 mm. The obtained DSC curves characterizing melting and solidification of the composite material are shown to be dependent upon the values of heating and cooling rates. Direct utilization of the measured DSC curves could result in an inexact representation of the sample enthalpy change. A simple procedure has been advised to obtain accurate quantitative results from the DSC measurements based on the estimation of the thermal resistance between the sample and its enclosure. Analysis of the evolution of latent heat of EPCM with temperature at different values of cooling/heating rates is presented.

  20. Evaluation of errors in determination of DNA melting curve registered with differential scanning calorimetry

    International Nuclear Information System (INIS)

    Lando, D.Y.; Fridman, A.S.; Galyuk, E.N.; Dalyan, Y.B.; Grigoryan, I.E.; Haroutiunian, S.G.

    2013-01-01

    The differential scanning calorimetry (DSC) is more sensitive than UV absorption spectrophotometry as a tool for the measurement of DNA melting curves. The advantage of DSC is a direct determination of differential melting curves (DMC) obtained without numerical differentiation. However, the difference between the helix-coil transition enthalpies of AT and GC base pairs can cause distortions in the shape of melting curve. Up to date, the errors caused by those distortions were not evaluated. In this study, a simple procedure of recalculation of a calorimetric DMC into a real DMC is developed. It demonstrates that the 'real' melting curve and differential melting curve deviate very slightly from the same two curves calculated from DSC data. The melting temperature and the temperature melting range are usually the same even if the difference in the enthalpies is several times higher than a real one

  1. Tritium Accounting Stability of a ZrCo Bed with 'In-Bed' Gas Flowing Calorimetry

    International Nuclear Information System (INIS)

    Hayashi, Takumi; Suzuki, Takumi; Yamada, Masayuki; Nishi, Masataka

    2005-01-01

    Zirconium-Cobalt (ZrCo) tritium storage bed with 'in-bed' gas flowing calorimetry has been developed as a self-assaying system for the Tritium Storage and Delivery System of ITER. The basic tritium accounting characteristics have been investigated and practical data on the accounting stability has been accumulated under gram level tritium storage for more than 8 years. The initial sensitivity of tritium was about 0.05 g and the accuracy (standard deviation of repeat measurements: two sigma) was about 0.15 g at full tritium storage of 25 g. This initial accounting performance has been maintained after tritium storage for more than 8 years by keeping constant accounting conditions at each inventory measurement. Almost no aging effect of tritium was found except accumulation of 3 He in the primary ZrCo tritide vessel, which was easily evacuated to keep initial accounting condition before each inventory measurement

  2. Integration and global analysis of isothermal titration calorimetry data for studying macromolecular interactions.

    Science.gov (United States)

    Brautigam, Chad A; Zhao, Huaying; Vargas, Carolyn; Keller, Sandro; Schuck, Peter

    2016-05-01

    Isothermal titration calorimetry (ITC) is a powerful and widely used method to measure the energetics of macromolecular interactions by recording a thermogram of differential heating power during a titration. However, traditional ITC analysis is limited by stochastic thermogram noise and by the limited information content of a single titration experiment. Here we present a protocol for bias-free thermogram integration based on automated shape analysis of the injection peaks, followed by combination of isotherms from different calorimetric titration experiments into a global analysis, statistical analysis of binding parameters and graphical presentation of the results. This is performed using the integrated public-domain software packages NITPIC, SEDPHAT and GUSSI. The recently developed low-noise thermogram integration approach and global analysis allow for more precise parameter estimates and more reliable quantification of multisite and multicomponent cooperative and competitive interactions. Titration experiments typically take 1-2.5 h each, and global analysis usually takes 10-20 min.

  3. Using compression calorimetry to characterize powder compaction behavior of pharmaceutical materials.

    Science.gov (United States)

    Buckner, Ira S; Friedman, Ross A; Wurster, Dale Eric

    2010-02-01

    The process by which pharmaceutical powders are compressed into cohesive compacts or tablets has been studied using a compression calorimeter. Relating the various thermodynamic results to relevant physical processes has been emphasized. Work, heat, and internal energy change values have been determined with the compression calorimeter for common pharmaceutical materials. A framework of equations has been proposed relating the physical processes of friction, reversible deformation, irreversible deformation, and inter-particle bonding to the compression calorimetry values. The results indicate that irreversible deformation dominated many of the thermodynamic values, especially the net internal energy change following the compression-decompression cycle. The relationships between the net work and the net heat from the complete cycle were very clear indicators of predominating deformation mechanisms. Likewise, the ratio of energy stored as internal energy to the initial work input distinguished the materials according to their brittle or plastic deformation tendencies. (c) 2009 Wiley-Liss, Inc. and the American Pharmacists Association.

  4. A digital Front-End and Readout MIcrosystem for calorimetry at LHC

    CERN Multimedia

    2002-01-01

    % RD-16 A Digital Front-End and Readout Microsystem for Calorimetry at LHC \\\\ \\\\Front-end signal processing for calorimetric detectors is essential in order to achieve adequate selectivity in the trigger function of an LHC experiment, with data identification and compaction before readout being required in the harsh, high rate environment of a high luminosity hadron machine. Other crucial considerations are the extremely wide dynamic range and bandwidth requirements, as well as the volume of data to be transferred to following stages of the trigger and readout system. These requirements are best met by an early digitalization of the detector information, followed by integrated digital signal processing and buffering functions covering the trigger latencies.\\\\ \\\\The FERMI (Front-End Readout MIcrosystem) is a digital implementation of the front-end and readout electronic chain for calorimeters. It is based on dynamic range compression, high speed A to D converters, a fully programmable pipeline/digital filter c...

  5. DETERMINATION OF HYDROGEN DESORBED THROUGH THERMAL CALORIMETRY IN A HIGH STRENGTH STEEL

    Directory of Open Access Journals (Sweden)

    Carolina A. Asmus

    2014-03-01

    Full Text Available The following study aims to quantify the release activation energy (Ea of hydrogen (H from lattice sites, reversible or irreversible, where the H can be trapped. Moreover, enthalpy changes associated with the main hydrogen (H trapping sites can be analyzed by means of differential scanning calorimetry (DSC. In this technique, the peak temperature measurement is determined at two different heating rates, 3ºC/min y 5ºC/min, from ambient temperature to 500°C. In order to simulate severe conditions of hydrogen income into resulfurized high strength steel, electrolytic permeation tests were performed on test tubes suitable for fatigue tests. Sometimes during charging, H promoters were aggregated to electrolytic solution. Subsequently, the test tubes were subjected to flow cycle fatigue tests. Finally, irreversible trap which anchor more strongly H atoms are MnS inclusions. Its role on hydrogen embrittlement during fatigue tests is conclusive.

  6. Building a graphite calorimetry system for the dosimetry of therapeutic x-ray beams

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Jung; Kim, Byoung Chul; Kim, Joong Hyun; Chung, Jae Pil; Kim, Hyun Moon; Yi, Chul Young [Korea Research Institute of Standards and Science, Daejeon (Korea, Republic of)

    2017-06-15

    A graphite calorimetry system was built and tested under irradiation. The noise level of the temperature measurement system was approximately 0.08 mK (peak to peak). The temperature of the core part rose by approximately 8.6 mK at 800 MU (monitor unit) for 6-MV X-ray beams, and it increased as X-ray energy increased. The temperature rise showed less spread when it was normalized to the accumulated charge, as measured by an external monitoring chamber. The radiation energy absorbed by the core part was determined to have values of 0.798 J/μC, 0.389 J/μC, and 0.352 J/μC at 6 MV, 10 MV, and 18 MV, respectively. These values were so consistent among repeated runs that their coefficient of variance was less than 0.15%.

  7. Theoretical studies of hadronic calorimetry for high luminosity, high energy colliders

    Energy Technology Data Exchange (ETDEWEB)

    Brau, J.E.; Gabriel, T.A.

    1989-01-01

    Experiments at the high luminosity, high energy colliders of the future are going to demand optimization of the state of the art of calorimetry design and construction. During the past few years, the understanding of the basic phenomenology of hadron calorimeters has advanced through paralleled theoretical and experimental investigations. The important underlying processes are reviewed to set the framework for the presentation of recent calculations of the expected performance of silicon detector based hadron calorimeters. Such devices employing uranium are expected to achieve the compensation condition (that is, e/h approx. 1.0) based on the understanding that has been derived from the uranium-liquid argon and uranium-plastic scintillator systems. In fact, even lead-silicon calorimeters are found to achieve the attractive value for the e/h ratio of 1.16 at 10 GeV. 62 refs., 22 figs., 3 tabs.

  8. New methodology developed for the differential scanning calorimetry analysis of polymeric matrixes incorporating phase change materials

    International Nuclear Information System (INIS)

    Barreneche, Camila; Solé, Aran; Miró, Laia; Martorell, Ingrid; Cabeza, Luisa F; Fernández, A Inés

    2012-01-01

    Nowadays, thermal comfort needs in buildings have led to an increase in energy consumption of the residential and service sectors. For this reason, thermal energy storage is shown as an alternative to achieve reduction of this high consumption. Phase change materials (PCM) have been studied to store energy due to their high storage capacity. A polymeric material capable of macroencapsulating PCM was developed by the authors of this paper. However, difficulties were found while measuring the thermal properties of these materials by differential scanning calorimetry (DSC). The polymeric matrix interferes in the detection of PCM properties by DSC. To remove this interfering effect, a new methodology which replaces the conventional empty crucible used as a reference in the DSC analysis by crucibles composed of the polymeric matrix was developed. Thus, a clear signal from the PCM is obtained by subtracting the new full crucible signal from the sample signal. (paper)

  9. Considerations on the design of front-end electronics for silicon calorimetry for the SSC

    International Nuclear Information System (INIS)

    Wintenberg, A.L.; Bauer, M.L.; Britton, C.L.; Kennedy, E.J.; Todd, R.A.; Berridge, S.C.; Bugg, W.M.

    1990-01-01

    Some considerations are described for the design of a silicon-based sampling calorimetry detector for the Superconducting Super Collider (SSC). The use of silicon as the detection medium allows fast, accurate, and fine-grained energy measurements - but for optimal performance, the front-end electronics must be matched to the detector characteristics and have the speed required by the high SSC interaction rates. The relation between the signal-to-noise rtio of the calorimeter electronics and the charge collection time, the preamplifier power dissipation, detector capacitance and leakage, charge gain, and signal shaping and sampling was studied. The electrostatic transformer connection was analyzed and found to be unusable for a tightly arranged calorimeter because of stray capacitance effects. The method of deconvolutional sampling was developed as a means for pileup correction following synchronous sampling and analog storage

  10. Analysis of the microbial growth in 60Co γ-irradiated foods by calorimetry

    International Nuclear Information System (INIS)

    Furuta, Masakazu; Hayashi, Toshio; Hamasaki, Koji; Wirkner, Sandra; Constantinoiu, Elena; Takahashi, Katsutada

    2002-01-01

    Using a heat conduction calorimeter equipped with 24 sample units the heat evolutions from growing 60 Co γ-irradiated bioburden of black pepper seeds and frozen beef were detected in the form of growth thermograms. 60 Co γ-irradiation affected the growth pattern in which a dose-dependent reduction of the growth rate constant was observed together with the retardation in growth, indicating a combination of bactericidal and bacteriostatic effects. We successfully determined the minimal inactivation doses for the two food samples using the relationship between the irradiation dose and the retardation in growth t α , or the growth rate constant μ obtained from the growth thermograms. These results strongly suggested the possibility of calorimetry as measure of predictive microbiology in food irradiation. (author)

  11. Analysis of the microbial growth in 60Co gamma-irradiated foods by calorimetry

    International Nuclear Information System (INIS)

    Furuta, M.; Hamasaki, K.; Wirkner, S.; Constantinoiu, E.; Takahashi, K.; Hayashi, T.

    2002-01-01

    Using a heat conduction calorimeter equipped with 24 sample units the heat evolutions from growing 60Co gamma-irradiated bioburden of black pepper seeds and frozen beef were detected in the form of growth thermograms. 60Co gamma-irradiation affected the growth pattern in which a dose-dependent reduction of the growth rate constant was observed together with the retardation in growth, indicating a combination of bactericidal and bacteriostatic effects. We successfully determined the minimal inactivation doses for the two food samples using the relationship between the irradiation dose and the retardation in growth talpha, or the growth rate constant mu obtained from the growth thermograms. These results strongly suggested the possibility of calorimetry as a measure of predictive microbiology in food irradiation

  12. CZECHOSLOVAK FOOTPRINTS IN THE DEVELOPMENT OF METHODS OF THERMOMETRY, CALORIMETRY AND THERMAL ANALYSIS

    Directory of Open Access Journals (Sweden)

    Pavel Holba

    2012-07-01

    Full Text Available A short history on the development of thermometric methods are reviewed accentuating the role of Rudolf Bárta in underpinning special thermoanalytical conferences and new journal Silikáty in fifties as well as Vladimir Šatava mentioning his duty in the creation of the Czech school on thermoanalytical kinetics. This review surveys the innovative papers dealing with thermal analysis and the related fields (e.g. calorimetry, kinetics which have been published by noteworthy postwar Czechoslovak scholars and scientists and by their disciples in 1950-1980. Itemized 227 references with titles show rich scientific productivity revealing that many of them were ahead of time even at international connotation.

  13. From calorimetry to medical imaging: a shining example of successful transfer!

    CERN Multimedia

    Caroline Duc

    2012-01-01

    A team at CERN has drawn inspiration from calorimetry methods developed for high-energy physics to create a new positron-emission tomography system for use in medical imaging, which they’ve dubbed AX-PET. With support from European and American laboratories*, the project is reaching fruition, as initial tests confirm its promise.   Snapshot of a “phantom”, a test object, surrounded by the AX-PET photon detectors. Positron-emission tomography (PET) is a medical imaging technique based on the matter-antimatter interaction that can provide a three-dimensional representation of the metabolic activity of an organ. To do so, radioactive marker molecules are first injected into the subject. As the marker decays, it emits positrons (antimatter particles), which are annihilated upon encountering electrons in the surrounding environment. The resulting flash, consisting of two photons, is detected by the PET machine. In conventional PET systems, it is impossible to improv...

  14. The design and PCB layout of the CDF Run 2 calorimetry readout module

    International Nuclear Information System (INIS)

    Theresa Shaw

    1999-01-01

    The CDF Calorimetry Readout module, called the ADMEM, has been designed to contain both the analog circuitry which digitizes the phototube charge pulses, and the digital logic which supports the readout of the results through the CDF Run 2 DAQ system. The ADMEM module is a 9Ux400mm VMEbus module, which is housed in a CDF VMEbus VIPA crate. The ADMEM must support near deadtimeless operation, with data being digitized and stored for possible readout every 132ns or 7.6 Mhz. This paper will discuss the implementation of the analog and digital portions of the ADMEM module, and how the board was laid out to avoid the coupling of digital noise into the analog circuitry

  15. Theoretical studies of hadronic calorimetry for high luminosity, high energy colliders

    International Nuclear Information System (INIS)

    Brau, J.E.; Gabriel, T.A.

    1989-01-01

    Experiments at the high luminosity, high energy colliders of the future are going to demand optimization of the state of the art of calorimetry design and construction. During the past few years, the understanding of the basic phenomenology of hadron calorimeters has advanced through paralleled theoretical and experimental investigations. The important underlying processes are reviewed to set the framework for the presentation of recent calculations of the expected performance of silicon detector based hadron calorimeters. Such devices employing uranium are expected to achieve the compensation condition (that is, e/h ∼ 1.0) based on the understanding that has been derived from the uranium-liquid argon and uranium-plastic scintillator systems. In fact, even lead-silicon calorimeters are found to achieve the attractive value for the e/h ratio of 1.16 at 10 GeV. 62 refs., 22 figs., 3 tabs

  16. Measurement and Model Validation of Nanofluid Specific Heat Capacity with Differential Scanning Calorimetry

    Directory of Open Access Journals (Sweden)

    Harry O'Hanley

    2012-01-01

    Full Text Available Nanofluids are being considered for heat transfer applications; therefore it is important to know their thermophysical properties accurately. In this paper we focused on nanofluid specific heat capacity. Currently, there exist two models to predict a nanofluid specific heat capacity as a function of nanoparticle concentration and material. Model I is a straight volume-weighted average; Model II is based on the assumption of thermal equilibrium between the particles and the surrounding fluid. These two models give significantly different predictions for a given system. Using differential scanning calorimetry (DSC, a robust experimental methodology for measuring the heat capacity of fluids, the specific heat capacities of water-based silica, alumina, and copper oxide nanofluids were measured. Nanoparticle concentrations were varied between 5 wt% and 50 wt%. Test results were found to be in excellent agreement with Model II, while the predictions of Model I deviated very significantly from the data. Therefore, Model II is recommended for nanofluids.

  17. Research and Development for the ATLAS Forward Calorimetry at the HL-LHC

    CERN Document Server

    Cheplakov, Alexander

    2015-01-01

    A total luminosity of 3000/fb is expected at the HL-LHC, which corresponds to total irradiation doses which are more than doubled compared to the original design, taking into account a safety factor of 2 representing our confidence in radiation background simulations. Moreover, the increased instantaneous luminosity will result in a much higher detector occupancy. The ATLAS Forward Calorimeters (FCal) will be affected by these factors. A rich R&D program is ongoing to evaluate the consequences of the LHC modernization and to investigate di_erent scenarios proposed for the Phase-II detector upgrade. This contribution will concentrate on simulation studies of the FCal degradation and on irradiation tests performed at the IBR-2m reactor in Dubna. Results from radiation-tolerant sensors and components of the future read-out and voltage distribution system for various upgrade options of the forward calorimetry will be presented.

  18. FLUKA studies of hadron-irradiated scintillating crystals for calorimetry at the High-Luminosity LHC

    CERN Document Server

    Quittnat, Milena Eleonore

    2015-01-01

    Calorimetry at the High-Luminosity LHC (HL-LHC) will be performed in a harsh radiation environment with high hadron fluences. The upgraded CMS electromagnetic calorimeter design and suitable scintillating materials are a focus of current research. In this paper, first results using the Monte Carlo simulation program FLUKA are compared to measurements performed with proton-irradiated LYSO, YSO and cerium fluoride crystals. Based on these results, an extrapolation to the behavior of an electromagnetic sampling calorimeter, using one of the inorganic scintillators above as an active medium, is performed for the upgraded CMS experiment at the HL-LHC. Characteristic parameters such as the induced ambient dose, fluence spectra for different particle types and the residual nuclei are studied, and the suitability of these materials for a future calorimeter is surveyed. Particular attention is given to the creation of isotopes in an LYSO-tungsten calorimeter that might contribute a prohibitive background to the measu...

  19. Resolving glass transition in Te-based phase-change materials by modulated differential scanning calorimetry

    Science.gov (United States)

    Chen, Yimin; Mu, Sen; Wang, Guoxiang; Shen, Xiang; Wang, Junqiang; Dai, Shixun; Xu, Tiefeng; Nie, Qiuhua; Wang, Rongping

    2017-10-01

    Glass transitions of Te-based phase-change materials (PCMs) were studied by modulated differential scanning calorimetry. It was found that both Ge2Sb2Te5 and GeTe are marginal glass formers with ΔT (= T x - T g) less than 2.1 °C when the heating rate is below 3 °C min-1. The fragilities of Ge2Sb2Te5 and GeTe can be estimated as 46.0 and 39.7, respectively, around the glass transition temperature, implying that a fragile-to-strong transition would be presented in such Te-based PCMs. The above results provide direct experimental evidence to support the investigation of crystallization kinetics in supercooled liquid PCMs.

  20. Stability of some Cactaceae proteins based on fluorescence, circular dichroism, and differential scanning calorimetry measurements.

    Science.gov (United States)

    Gorinstein, S; Zemser, M; Vargas-Albores, F; Ochoa, J L; Paredes-Lopez, O; Scheler, C; Aksu, S; Salnikow, J

    1999-02-01

    Characterization of three cactus proteins (native and denatured) from Machaerocereus gummosus (Pitahaya agria), Lophocereu schottii (Garambullo), and Cholla opuntia (Cholla), was based on electrophoretic, fluorescence, CD (circular dichroism), DSC (differential scanning calorimetry), and FT-IR (Fourier transform infrared) measurements. The obtained results of intrinsic fluorescence, DSC, and CD were dissimilar for the three species of cactus, providing evidence of differences in secondary and tertiary structures. Cactus proteins may be situated in the following order corresponding to their relative stability: Machaerocereus gummosus (Pitahaya agria) > Cholla opuntia (Cholla) > Lophocereu schottii (Garambullo). Thermodynamic properties of proteins and their changes upon denaturation (temperature of denaturation, enthalphy, and the number of ruptured hydrogen bonds) were correlated with the secondary structure of proteins and disappearance of alpha-helix.

  1. Indirect genetic effects and kin recognition

    DEFF Research Database (Denmark)

    Alemu, Setegn Worku; Berg, Peer; Janss, Luc

    2014-01-01

    Social interactions among individuals are widespread, both in natural and domestic populations. As a result, trait values of individuals may be affected by genes in other individuals, a phenomenon known as indirect genetic effects (IGEs). IGEs can be estimated using linear mixed models. The tradi......Social interactions among individuals are widespread, both in natural and domestic populations. As a result, trait values of individuals may be affected by genes in other individuals, a phenomenon known as indirect genetic effects (IGEs). IGEs can be estimated using linear mixed models...... present a reduced model that yields estimates of the total heritable effects on kin, on non-kin and on all social partners of an individual, as well as the total heritable variance for response to selection. Finally we discuss the consequences of analysing data in which IGEs depend on relatedness using...

  2. Lack of indirect sensitization in vivo

    International Nuclear Information System (INIS)

    Hetzel, F.W.; Avery, K.; Mensinger, M.; Frinak, S.; Tidwell, C.

    1985-01-01

    The possible utility of respiratory inhibiting drugs as indirect radiation sensitizers has been investigated in both in vitro and in vivo systems. In vitro studies were conducted in V79 monolayer and spheroid cultures examining both respiratory inhibition and radiation survival as end points. These drugs (BCNU, Mustargen and Chlorambucil) were found to be potent respiratory inhibitors and, in the spheroid system, to be effective indirect radiation sensitizers with enhancement ratios of approximately 2.0. In vivo studies with these drugs have also been conducted in a C/sub 3/H mouse MCa tumor system to determine if the same reoxygenation effect observed in spheroids could be demonstrated in the solid tumor system. Detailed microelectrode studies, employing each drug at its LD/sub 10/ level, have been unable to demonstrate any drug induced reoxygenation for any of the drugs tested. Complete details are presented

  3. Direct or indirect - that is the question!

    DEFF Research Database (Denmark)

    Pallesen, Ulla

    2016-01-01

    Time has passed since the prevention of caries was performed by extending cavity preparations wide in the tooth and below the gingiva. In the same period adhesive techniques have improved and nowadays made it possible to extend the indications for direct composite resin restorations, also when...... rather destroyed teeth need to be restored. Although much can be solved by direct fillings and thereby make treatments less invasive for the tooth and less expensive for the patient, there still will be teeth, where the prognosis is improved, if an indirect restoration in terms of an inlay, onlay...... or crown is made. Factors as remaining tooth structure, endodontic treatment, number of teeth, caries risk, para-functional habits, material properties, economy etc. will all have an influence, when the dentist guides the patient to choose the best solution. What is best for the tooth – direct or indirect...

  4. Social intervention and risk reduction - indirect countermeasures

    International Nuclear Information System (INIS)

    Higgins, N.A.; Morrey, M.

    1996-01-01

    An indirect countermeasure (IC) is an action which is intended to mitigate detrimental effects experienced by individuals or the community after an accident. Indirect countermeasures (ICs) achieve this, both by averting radiation risks arising from the accident, but by removing or reducing other risks and sources of stress or harm to which the community may be subject. ICs naturally fall into two categories: social action ICs, which range from introducing compensation payments to providing information centres; and risk reducing ICs which mitigate risks to which the population might be exposed, such as radon. By including a consideration of ICs in an assessment of the optimal response, it is likely that a decision maker will become aware of a greater range of harms and benefits that might result from the application of a countermeasure. The decision maker will then be in a better position to judge the appropriateness of any action. (author)

  5. Irreversible denaturation of maltodextrin glucosidase studied by differential scanning calorimetry, circular dichroism, and turbidity measurements.

    Science.gov (United States)

    Goyal, Megha; Chaudhuri, Tapan K; Kuwajima, Kunihiro

    2014-01-01

    Thermal denaturation of Escherichia coli maltodextrin glucosidase was studied by differential scanning calorimetry, circular dichroism (230 nm), and UV-absorption measurements (340 nm), which were respectively used to monitor heat absorption, conformational unfolding, and the production of solution turbidity. The denaturation was irreversible, and the thermal transition recorded at scan rates of 0.5-1.5 K/min was significantly scan-rate dependent, indicating that the thermal denaturation was kinetically controlled. The absence of a protein-concentration effect on the thermal transition indicated that the denaturation was rate-limited by a mono-molecular process. From the analysis of the calorimetric thermograms, a one-step irreversible model well represented the thermal denaturation of the protein. The calorimetrically observed thermal transitions showed excellent coincidence with the turbidity transitions monitored by UV-absorption as well as with the unfolding transitions monitored by circular dichroism. The thermal denaturation of the protein was thus rate-limited by conformational unfolding, which was followed by a rapid irreversible formation of aggregates that produced the solution turbidity. It is thus important to note that the absence of the protein-concentration effect on the irreversible thermal denaturation does not necessarily means the absence of protein aggregation itself. The turbidity measurements together with differential scanning calorimetry in the irreversible thermal denaturation of the protein provided a very effective approach for understanding the mechanisms of the irreversible denaturation. The Arrhenius-equation parameters obtained from analysis of the thermal denaturation were compared with those of other proteins that have been reported to show the one-step irreversible thermal denaturation. Maltodextrin glucosidase had sufficiently high kinetic stability with a half-life of 68 days at a physiological temperature (37°C).

  6. Hydrogen concentration determination in pressure tube samples using differential scanning calorimetry (dsc)

    International Nuclear Information System (INIS)

    Marinescu, R.; Mincu, M.

    2015-01-01

    Zirconium alloys are widely used as a structural material in nuclear reactors. It is known that zirconium based cladding alloys absorb hydrogen as a result of service in a pressurized water reactor. Hydrogen absorbed (during operation of the reactor) in the zirconium alloy, out of which the pressure tube is made, is one of the major factors determining the life time of the pressure tube. For monitoring the hydrides, samples of the pressure tube are periodically taken and analyzed. At normal reactor operating temperature, hydrogen has limited solubility in the zirconium lattice and precipitates out of solid solution as zirconium hydride when the solid solubility is exceeded. As a consequences material characterization of Zr-2.5Nb CANDU pressure tubes is required after manufacturing but also during the operation to assess its structural integrity and to predict its behavior until the next in-service inspection. Hydrogen and deuterium concentration determination is one of the most important parameters to be evaluated during the experimental tests. Hydrogen present in zirconium alloys has a strong effect of weakening. Following the zirconium-hydrogen reaction, the resulting zirconium hydride precipitates in the mass of material. Weakening of the material, due to the presence of 10 ppm of precipitated hydrogen significantly affects some of its properties. The concentration of hydrogen in a sample can be determined by several methods, one of them being the differential scanning calorimetry (DSC). The principle of the method consists in measuring the difference between the amount of heat required to raise the temperature of a sample and a reference to a certain value. The experiments were made using a TA Instruments DSC Q2000 calorimeter. This paper contains experimental work for hydrogen concentration determination by Differential Scanning Calorimetry (DSC) method. Also, the reproducibility and accuracy of the method used at INR Pitesti are presented. (authors)

  7. An investigation of student thinking regarding calorimetry, entropy, and the second law of thermodynamics

    Science.gov (United States)

    Christensen, Warren Michael

    This thesis constitutes an investigation into student understanding of concepts in thermal physics in an introductory calculus-based university physics course. Nearly 90% of students enrolled in the course had previous exposure to thermodynamics concepts in chemistry and/or high-school physics courses. The two major thrusts of this work are (1) an exploration of student approaches to solving calorimetry problems involving two substances with differing specific heats, and (2) a careful probing of student ideas regarding certain aspects of entropy and the second law of thermodynamics. We present extensive free-response, interview, and multiple-choice data regarding students' ideas, collected both before and after instruction from a diverse set of course semesters and instructors. For topics in calorimetry, we found via interviews that students frequently get confused by, or tend to overlook, the detailed proportional reasoning or algebraic procedures that could lead to correct solutions. Instead, students often proceed with semi-intuitive reasoning that at times may be productive, but more often leads to inconsistencies and non-uniform conceptual understanding. Our investigation of student thinking regarding entropy suggests that prior to instruction, students have consistent and distinct patterns of incorrect or incomplete responses that often persist despite deliberate and focused efforts by the instructor. With modified instruction based on research-based materials, significant learning gains were observed on certain key concepts, e.g., that the entropy of the universe increases for all non-ideal processes. The methodology for our work is described, the data are discussed and analyzed, and a description is given of goals for future work in this area.

  8. Efficient Isothermal Titration Calorimetry Technique Identifies Direct Interaction of Small Molecule Inhibitors with the Target Protein.

    Science.gov (United States)

    Gal, Maayan; Bloch, Itai; Shechter, Nelia; Romanenko, Olga; Shir, Ofer M

    2016-01-01

    Protein-protein interactions (PPI) play a critical role in regulating many cellular processes. Finding novel PPI inhibitors that interfere with specific binding of two proteins is considered a great challenge, mainly due to the complexity involved in characterizing multi-molecular systems and limited understanding of the physical principles governing PPIs. Here we show that the combination of virtual screening techniques, which are capable of filtering a large library of potential small molecule inhibitors, and a unique secondary screening by isothermal titration calorimetry, a label-free method capable of observing direct interactions, is an efficient tool for finding such an inhibitor. In this study we applied this strategy in a search for a small molecule capable of interfering with the interaction of the tumor-suppressor p53 and the E3-ligase MDM2. We virtually screened a library of 15 million small molecules that were filtered to a final set of 80 virtual hits. Our in vitro experimental assay, designed to validate the activity of mixtures of compounds by isothermal titration calorimetry, was used to identify an active molecule against MDM2. At the end of the process the small molecule (4S,7R)-4-(4-chlorophenyl)-5-hydroxy-2,7-dimethyl-N-(6-methylpyridin-2-yl)-4,6,7,8 tetrahydrIoquinoline-3-carboxamide was found to bind MDM2 with a dissociation constant of ~2 µM. Following the identification of this single bioactive compound, spectroscopic measurements were used to further characterize the interaction of the small molecule with the target protein. 2D NMR spectroscopy was used to map the binding region of the small molecule, and fluorescence polarization measurement confirmed that it indeed competes with p53.

  9. The thermochemical behavior of some binary shape memory alloys by high temperature direct synthesis calorimetry

    International Nuclear Information System (INIS)

    Meschel, S.V.; Pavlu, J.; Nash, P.

    2011-01-01

    Research highlights: → We studied 14 shape memory alloys. → The enthalpies of formation and structure characteristics are summarized. → Theoretical predictions by ab initio calculations compare better with experimental measurements than Miedema's semi empirical model. - Abstract: The standard enthalpies of formation of some shape memory alloys have been measured by high temperature direct synthesis calorimetry at 1373 K. The following results (in kJ/mol of atoms) are reported: CoCr (-0.3 ± 2.9); CuMn (-3.7 ± 3.2); Cu 3 Sn (-10.4 ± 3.1); Fe 2 Tb (-5.5 ± 2.4); Fe 2 Dy (-1.6 ± 2.9); Fe 17 Tb 2 (-2.1 ± 3.1); Fe 17 Dy 2 (-5.3 ± 1.7); FePd 3 (-16.0 ± 2.7); FePt (-23.0 ± 1.9); FePt 3 (-20.7 ± 2.3); NiMn (-24.9 ± 2.6); TiNi (-32.7 ± 1.0); TiPd (-60.3 ± 2.5). The results are compared with some earlier experimental values obtained by calorimetry and by EMF technique. They are also compared with predicted values on the basis of the semi empirical model of Miedema and co-workers and with ab initio calculations when available. We will also assess the available information regarding the structures of these alloys.

  10. Gas phase enthalpies of formation of nitrobenzamides using combustion calorimetry and thermal analysis

    International Nuclear Information System (INIS)

    Ximello, Arturo; Flores, Henoc; Rojas, Aarón; Adriana Camarillo, E.; Patricia Amador, M.

    2014-01-01

    Graphical abstract: - Highlights: • Formation enthalpies of the nitrobenzamides were derived from combustion calorimetry. • Enthalpies of vaporisation and sublimation were calculated by thermogravimetry. • From gas phase enthalpies of formation the stability of the isomers is studied. • Stability of isomers is not driven by a steric hindrance between functional groups. - Abstract: The standard molar energies of combustion of 2-nitrobenzamide, 3-nitrobenzamide and 4-nitrobenzamide were determined with an isoperibolic, static-bomb, combustion calorimeter. From the combustion results, the standard molar enthalpies of combustion and formation for these compounds in the condensed phase at T = 298.15 K were derived. Subsequently, to determine the enthalpies of sublimation, the vapour pressure data as a function of the temperature for the compounds under investigation were estimated using thermogravimetry by applying Langmuir’s equation, and the enthalpies of vaporisation were derived. Standard enthalpies of fusion were measured by differential scanning calorimetry then added to those of vaporisation to obtain reliable results for the enthalpy of sublimation. From the combustion and sublimation data, the gas phase enthalpies of formation were determined to be (−138.9 ± 3.5) kJ · mol −1 , (−122.9 ± 2.9) kJ · mol −1 and (−108.5 ± 3.7) kJ · mol −1 for the ortho, meta and para isomers of nitrobenzamide, respectively. The meaning of these results with regard to the enthalpic stability of these molecular structures is discussed herein

  11. Studies on direct and indirect electrochemical immunoassays

    OpenAIRE

    Buckley, Eileen

    1989-01-01

    Two approaches to electrochemical immunoassay are reported. The first approach was an indirect method, involving an electroactive, enzyme-catalysed, substrate to product reaction. Conditions were optimised for the amperometric detection of para-aminophenol, the electroactive product of the alkaline phosphatase catalysed hydrolysis of a new substrate, p-aminophenylphosphate, after separation by HPLC. The second approach involved the direct electrochemical detection of an immunoglo...

  12. Color indirect effects on melatonin regulation

    Science.gov (United States)

    Mian, Tian; Liu, Timon C.; Li, Yan

    2002-04-01

    Color indirect effect (CIE) is referred to as the physiological and psychological effects of color resulting from color vision. In previous papers, we have studied CIE from the viewpoints of the integrated western and Chinese traditional medicine, put forward the color-autonomic- nervous-subsystem model (CAM), and provided its time-theory foundation. In this paper, we applied it to study light effects on melatonin regulation in humans, and suggested that it is CIE that mediates light effects on melatonin suppression.

  13. Software Prefetching for Indirect Memory Accesses

    OpenAIRE

    Ainsworth, Sam; Jones, Timothy

    2017-01-01

    Many modern data processing and HPC workloads are heavily memory-latency bound. A tempting proposition to solve this is software prefetching, where special non-blocking loads are used to bring data into the cache hierarchy just before being required. However, these are difficult to insert to effectively improve performance, and techniques for automatic insertion are currently limited. This paper develops a novel compiler pass to automatically generate software prefetches for indirect mem...

  14. Draft of textbook focused on indirect taxes

    OpenAIRE

    Nováková, Hana

    2012-01-01

    The diploma thesis is about draft of textbook which is focused on indirect taxes for business school. The thesis is divided into theoretical and practical part. The theoretical part is focused on teaching tax issues at business school. Readers are introduced with basic studying documents, for example framework educational program and school educational program. In the following part I have conducted didactic analysis of curriculum and textbook of economics for business schools. The draft of t...

  15. Comment traduire en japonais les styles indirect et indirect libre de Madame Bovary ?

    Directory of Open Access Journals (Sweden)

    Hisaki Sawasaki

    2012-03-01

    Full Text Available Parmi les difficultés rencontrées lors de la traduction des textes littéraires occidentaux, en japonais, nous examinons le problème des styles indirect et indirect libre. Pour cela, en effectuant une petite mise au point grammaticale, nous comparons sept traductions de Madame Bovary de Gustave Flaubert, dont les dates de parution s’étendent sur une cinquantaine d’années. Cette période s’apparente, de notre point de vue, à un long itinéraire pour assimiler la notion occidentale des styles direct et indirect, tout en la conciliant avec les particularités du japonais. D’un autre côté, ce travail acharné des traducteurs a influencé quelque peu la langue japonaise. On trouve dans l’annexe tous les textes en japonais examinés.We will examine the difficulties met when translating Western literary texts in Japanese, in particular the problem of indirect and free indirect styles. We will define the grammatical issue and compare seven translations of Madame Bovary, published over a fifty year period. This time can be likened to a long path taken to digest the Western notion of direct and indirect styles, while reconciling it with Japanese language characteristics. On the other hand the translators’ relentless work has somewhat influenced the Japanese language. The annex will present all the Japanese texts examined.

  16. Use of isothermal titration calorimetry to study the interaction of short-chain alcohols with lipid membranes

    DEFF Research Database (Denmark)

    Trandum, Christa; Westh-Andersen, Peter; Jørgensen, Kent

    1999-01-01

    of short-chain alcohols on Lipid bilayers. isothermal titration calorimetry (ITC) has been used to determine the energy involved in the association of the alcohols with lipid bilayers. Pure unilamellar DMPC liposomes and DMPC liposomes incorporated with different amounts of cholesterol, sphingomyelin...... dependent on the lipid bilayer composition. In the presence of high concentrations of cholesterol, the binding enthalpy of ethanol is decreased, whereas the presence of ceramides enhances the enthalpic response of the lipid bilayer to ethanol. Isothermal titration calorimetry offers a new methodology...

  17. Clinical Outcomes of patients with coronary artery disease who underwent FFR evaluation of intermediate coronary lesionS– COFFRS study

    Directory of Open Access Journals (Sweden)

    Srinivasa Prasad

    2017-07-01

    Conclusion: In our experience, MACE events were not higher in patients with FFR > 0.8 and kept under medical therapy and were similarly lower in patients with FFR ≤0.8 and underwent revascularisation (p = 0.73. Also MACE events were higher in patients with FFR ≤ 0.8 and did not undergo revascularisation compared to other two appropriately treated groups (p = 0.03. FFR based revascularization decision appears to be a safe strategy in Indian patients.

  18. Indirect Comprehensive Review Board (ICRB). Final Report

    International Nuclear Information System (INIS)

    1996-12-01

    Lockheed Martin Idaho Technologies Company (LMITCO) used a systems engineering approach to take the first step toward defining a requirements baseline for all indirect work at the Idaho National Engineering Laboratory. The intent of this effort was to define the requirements for indirect work, identify the activities necessary to meet the requirements, and to produce defensible cost estimates for the work. The result of this effort is a scrubbed-down, defensible budget for all indirect work in FY 1997. Buying power for each dollar of direct work was increased by $.02. Recommendations are identified for improvements to this process in FY 1998. The purpose of this report is twofold. First is to report the final results of the 1996 ICRB process, and second is to document the process used such that incremental improvements may be made in future years. Objectives, processes, and approaches are described to provide a trail for future boards. Appendices contain copies of board composition, documentation of the process, as well as the actual training materials

  19. Interactive indirect illumination using adaptive multiresolution splatting.

    Science.gov (United States)

    Nichols, Greg; Wyman, Chris

    2010-01-01

    Global illumination provides a visual richness not achievable with the direct illumination models used by most interactive applications. To generate global effects, numerous approximations attempt to reduce global illumination costs to levels feasible in interactive contexts. One such approximation, reflective shadow maps, samples a shadow map to identify secondary light sources whose contributions are splatted into eye space. This splatting introduces significant overdraw that is usually reduced by artificially shrinking each splat's radius of influence. This paper introduces a new multiresolution approach for interactively splatting indirect illumination. Instead of reducing GPU fill rate by reducing splat size, we reduce fill rate by rendering splats into a multiresolution buffer. This takes advantage of the low-frequency nature of diffuse and glossy indirect lighting, allowing rendering of indirect contributions at low resolution where lighting changes slowly and at high-resolution near discontinuities. Because this multiresolution rendering occurs on a per-splat basis, we can significantly reduce fill rate without arbitrarily clipping splat contributions below a given threshold-those regions simply are rendered at a coarse resolution.

  20. Indirect evolution of social fitness inequalities and facultative social exploitation.

    Science.gov (United States)

    Nair, Ramith R; Fiegna, Francesca; Velicer, Gregory J

    2018-03-28

    Microbial genotypes with similarly high proficiency at a cooperative behaviour in genetically pure groups often exhibit fitness inequalities caused by social interaction in mixed groups. Winning competitors in this scenario have been referred to as 'cheaters' in some studies. Such interaction-specific fitness inequalities, as well as social exploitation (in which interaction between genotypes increases absolute fitness), might evolve due to selection for competitiveness at the focal behaviour or might arise non-adaptively due to pleiotropy, hitchhiking or genetic drift. The bacterium Myxococcus xanthus sporulates during cooperative development of multicellular fruiting bodies. Using M. xanthus lineages that underwent experimental evolution in allopatry without selection on sporulation, we demonstrate that interaction-specific fitness inequalities and facultative social exploitation during development readily evolved indirectly among descendant lineages. Fitness inequalities between evolved genotypes were not caused by divergence in developmental speed, as faster-developing strains were not over-represented among competition winners. In competitions between ancestors and several evolved strains, all evolved genotypes produced more spores than the ancestors, including losers of evolved-versus-evolved competitions, indicating that adaptation in non-developmental contexts pleiotropically increased competitiveness for spore production. Overall, our results suggest that fitness inequalities caused by social interaction during cooperative processes may often evolve non-adaptively in natural populations. © 2018 The Authors.

  1. Spatially indirect excitons in coupled quantum wells

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Chih-Wei Eddy [Univ. of California, Berkeley, CA (United States)

    2004-03-01

    Microscopic quantum phenomena such as interference or phase coherence between different quantum states are rarely manifest in macroscopic systems due to a lack of significant correlation between different states. An exciton system is one candidate for observation of possible quantum collective effects. In the dilute limit, excitons in semiconductors behave as bosons and are expected to undergo Bose-Einstein condensation (BEC) at a temperature several orders of magnitude higher than for atomic BEC because of their light mass. Furthermore, well-developed modern semiconductor technologies offer flexible manipulations of an exciton system. Realization of BEC in solid-state systems can thus provide new opportunities for macroscopic quantum coherence research. In semiconductor coupled quantum wells (CQW) under across-well static electric field, excitons exist as separately confined electron-hole pairs. These spatially indirect excitons exhibit a radiative recombination time much longer than their thermal relaxation time a unique feature in direct band gap semiconductor based structures. Their mutual repulsive dipole interaction further stabilizes the exciton system at low temperature and screens in-plane disorder more effectively. All these features make indirect excitons in CQW a promising system to search for quantum collective effects. Properties of indirect excitons in CQW have been analyzed and investigated extensively. The experimental results based on time-integrated or time-resolved spatially-resolved photoluminescence (PL) spectroscopy and imaging are reported in two categories. (i) Generic indirect exciton systems: general properties of indirect excitons such as the dependence of exciton energy and lifetime on electric fields and densities were examined. (ii) Quasi-two-dimensional confined exciton systems: highly statistically degenerate exciton systems containing more than tens of thousands of excitons within areas as small as (10 micrometer)2 were

  2. Citrus aurantium Naringenin Prevents Osteosarcoma Progression and Recurrence in the Patients Who Underwent Osteosarcoma Surgery by Improving Antioxidant Capability

    Directory of Open Access Journals (Sweden)

    Lirong Zhang

    2018-01-01

    Full Text Available Citrus aurantium is rich in flavonoids, which may prevent osteosarcoma progression, but its related molecular mechanism remains unclear. Flavonoids were extracted from C. aurantium and purified by reparative HPLC. Each fraction was identified by using electrospray ionisation mass spectrometry (ESI-MS. Three main components (naringin, naringenin, and hesperetin were isolated from C. aurantium. Naringenin inhibited the growth of MG-63 cells, whereas naringin and hesperetin had no inhibitory function on cell growth. ROS production was increased in naringin- and hesperetin-treated groups after one day of culture while the level was always lowest in the naringenin-treated group after three days of culture. 95 osteosarcoma patients who underwent surgery were assigned into two groups: naringenin group (NG, received 20 mg naringenin daily, n=47 and control group (CG, received 20 mg placebo daily, n=48. After an average of two-year follow-up, osteosarcoma volumes were smaller in the NG group than in the CG group (P>0.01. The rate of osteosarcoma recurrence was also lower in the NG group than in CG group. ROS levels were lower in the NG group than in the CG group. Thus, naringenin from Citrus aurantium inhibits osteosarcoma progression and local recurrence in the patients who underwent osteosarcoma surgery by improving antioxidant capability.

  3. Citrus aurantium Naringenin Prevents Osteosarcoma Progression and Recurrence in the Patients Who Underwent Osteosarcoma Surgery by Improving Antioxidant Capability.

    Science.gov (United States)

    Zhang, Lirong; Xu, Xiaohua; Jiang, Tiechao; Wu, Kunzhe; Ding, Chuanbo; Liu, Zhen; Zhang, Xuanhe; Yu, Tianhua; Song, Changlong

    2018-01-01

    Citrus aurantium is rich in flavonoids, which may prevent osteosarcoma progression, but its related molecular mechanism remains unclear. Flavonoids were extracted from C. aurantium and purified by reparative HPLC. Each fraction was identified by using electrospray ionisation mass spectrometry (ESI-MS). Three main components (naringin, naringenin, and hesperetin) were isolated from C. aurantium . Naringenin inhibited the growth of MG-63 cells, whereas naringin and hesperetin had no inhibitory function on cell growth. ROS production was increased in naringin- and hesperetin-treated groups after one day of culture while the level was always lowest in the naringenin-treated group after three days of culture. 95 osteosarcoma patients who underwent surgery were assigned into two groups: naringenin group (NG, received 20 mg naringenin daily, n = 47) and control group (CG, received 20 mg placebo daily, n = 48). After an average of two-year follow-up, osteosarcoma volumes were smaller in the NG group than in the CG group ( P > 0.01). The rate of osteosarcoma recurrence was also lower in the NG group than in CG group. ROS levels were lower in the NG group than in the CG group. Thus, naringenin from Citrus aurantium inhibits osteosarcoma progression and local recurrence in the patients who underwent osteosarcoma surgery by improving antioxidant capability.

  4. Tumor deposit is a poor prognostic indicator in patients who underwent simultaneous resection for synchronous colorectal liver metastases

    Directory of Open Access Journals (Sweden)

    Lin Q

    2015-01-01

    Full Text Available Qi Lin,# Ye Wei,# Li Ren,# Yunshi Zhong,# Chunzhi Qin, Peng Zheng, Pingping Xu, Dexiang Zhu, Meiling Ji, Jianmin XuDepartment of General Surgery, Zhongshan Hospital, Fudan University, Shanghai, People's Republic of China#These authors contributed equally to this workBackground: Tumor deposits are one of the important influencing factors among the different editions of Tumor, Node, Metastasis classification. Incidence and prognosis of tumor deposits in stage I, II, and III colorectal cancer patients has been explored. The aim of this study was to determine the prognostic value of tumor deposits in stage IV colorectal cancer patients who underwent simultaneous resection for synchronous colorectal liver metastases (SCRLM.Methods: Clinicopathological and outcome data of 146 consecutive SCRLM patients who underwent simultaneous R0 resection between July 2003 and July 2013 were collected from our prospectively established SCRLM database. The prognostic value of tumor deposits was evaluated by Kaplan–Meier and Cox regression analysis.Results: Tumor deposits were detected in 41.8% (61/146 of these SCRLM patients. Tumor deposits were significantly correlated with lymph node metastasis and nerve invasion of the primary tumors (P=0.002, P=0.041; respectively. The Kaplan–Meier survival analysis revealed that the overall survival (OS and disease-free survival (DFS of SCRLM patients with tumor deposits were significantly poorer than those with no tumor deposits (P=0.039, P=0.001; respectively. And with multivariate analysis, we found that positive tumor deposits were significantly associated with shorter DFS independent of lymph node status (P=0.002. Subgroup analysis found that of the 57 SCRLM patients with negative lymph node status, the OS and DFS of patients with positive tumor deposits were significantly shorter than those with negative tumor deposits (P=0.002 and P=0.031, respectively. Of the 89 patients with positive lymph node status, the OS of

  5. The use of immersion calorimetry in the determination of micropore distribution of carbons in the course of activation

    OpenAIRE

    Kraehenbuehl, F.; Stoeckli, Fritz; Addoun, A.; Ehrburger, P.; Donnet, J. B.

    2007-01-01

    The combination of gas-solid adsorption experiments with immersion calorimetry of carbons into liquids of increasing molecular dimensions leads to accurate micropore distributions in the range 0.4-0.8 nm. This technique is used to study the development of the micropore structure during activation of carbons with CO2 or KOH.

  6. Isothermal titration calorimetry and surface plasmon resonance allow quantifying substrate binding to different binding sites of Bacillus subtilis xylanase

    DEFF Research Database (Denmark)

    Cuyvers, Sven; Dornez, Emmie; Abou Hachem, Maher

    2012-01-01

    Isothermal titration calorimetry and surface plasmon resonance were tested for their ability to study substrate binding to the active site (AS) and to the secondary binding site (SBS) of Bacillus subtilis xylanase A separately. To this end, three enzyme variants were compared. The first...

  7. Kinetic properties of two Rhizopus exo-polygalacturonase enzymes hydrolyzing galacturonic acid oligomers using isothermal titration calorimetry

    Science.gov (United States)

    The kinetic characteristics of two Rhizopus oryzae exo-polygalacturonases acting on galacturonic acid oligomers (GalpA) were determined using isothermal titration calorimetry (ITC). RPG15 hydrolyzing (GalpA)2 demonstrated a Km of 55 uM and kcat of 10.3 s^-1^ while RPG16 was shown to have greater af...

  8. Thermodynamic characteristics of the acid-base equilibria of taurine in aqueous solutions, according to calorimetry data

    Science.gov (United States)

    Gridchin, S. N.; Shekhanov, R. F.; Pyreu, D. F.

    2015-02-01

    Enthalpies of the neutralization and protonation of taurine (HL) are measured by direct calorimetry at 298.15 K and ionic strengths of 0.3, 0.5, and 1.0 (KNO3). The standard thermodynamic characteristics of HL protolytic equilibria are calculated.

  9. Influence of frost damage and sample preconditioning on the porosity characterization of cement based materials using low temperature calorimetry

    DEFF Research Database (Denmark)

    Wu, Min; Fridh, Katja; Johannesson, Björn

    2015-01-01

    Low temperature calorimetry (LTC) can be used to study the meso-porosity of cement based materials. The influence of frost damage on the meso-porosity determination by LTC was explored on a model material MCM-41 and two cement pastes by conducting repeated cycles of freezing and melting measureme...

  10. Indirect measurements of X-ray spectra

    International Nuclear Information System (INIS)

    Mainardi, R.T.

    2006-01-01

    To the effects of measuring the spectral distribution of the radiation emitted by the x-ray tubes and electron accelerators, numerous procedures that are grouped in two big categories exist at the present time: direct and indirect methods. The first ones use high resolution detectors that should be positioned, together with the appropriate collimator, in the direction of the x ray beam. The user should be an expert in the use and correction of the obtained data by the different effects that affect the detector operation such as efficiency and resolution in terms of the energy of the detected radiation. The indirect procedures, although its are more simple to use, its also require a considerable space along the beam to position the ionization chamber and the necessary absorbents to construct by this way the denominated attenuation curve. We will analyze the operation principle of the indirect methods and a new proposal in which such important novelties are introduced as the beam dispersion to avoid to measure along the main beam and that of determination of the attenuation curve in simultaneous form. By this way, with a single shot of the tube, the attenuation curve is measured, being necessary at most a shot of additional calibration to know the relative response of the detectors used in the experimental array. The physical processes involved in the obtaining of an attenuation curve are very well well-known and this it finishes it can be theoretically calculated if the analytic form of the spectrum is supposed well-known. Finally, we will see a spectra reconstruction example with the Kramers parametric form and comparisons with numeric simulations carried out with broadly validated programs as well as the possibility of the use of solid state dosemeters in the obtention of the attenuation curve. (Author)

  11. [Evaluation of the antithrombotic strategy in low thrombotic risk patients who underwent aortic valve replacement with a bioprosthesis].

    Science.gov (United States)

    Aceves-Velázquez, Eduardo; Vieyra-Herrera, Gerardo; Rodríguez-Chávez, Laura; Herrera-Alarcón, Valentín

    2017-07-16

    According to current guidelines, in patients without additional risk factors who have undergone aortic valve replacement with a bioprosthesis, anticoagulation in the first 3 months after surgery is still a matter of debate. According to current evidence, aspirin in low doses is a reasonable alternative to vitamin K antagonists (VKA). A comparison is made between the incidence of thrombotic and haemorrhagic complications in patients with low thrombotic risk who underwent aortic valve replacement with a bioprosthesis in the National Institute of Cardiology of Ignacio Chávez of Mexico. The hypothesis: aspirin as monotherapy has a beneficial effect compared to VKA. The studied patients were the low thrombotic risk patients who underwent aortic valve replacement with a bioprosthesis in the National Institute of Cardiology of Ignacio Chávez of Mexico from 2011 to 2015. The groups studied were: aspirin only, VKA only, and the combination of VKA plus aspirin. The patients were retrospectively followed-up for 12 months, and the thrombotic and haemorrhagic complications were documented. Of the 231 patients included in the study, only one patient in the VKA only group presented with a haemorrhagic complication. No thrombotic complications were observed. In the present study no thrombotic complications were observed in patients who did not receive anticoagulation in the first 3 months after an aortic valve replacement with a bioprosthesis after a follow up period of 12 months. This suggests that the use of aspirin only is safe during this period. Copyright © 2017 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.

  12. Autotransplantation of spleen tissue in children with mansonic schistosomiasis who underwent splenectomy: Evaluation of splenic residual functions

    Directory of Open Access Journals (Sweden)

    Brandt Carlos Teixeira

    1998-01-01

    Full Text Available Autotransplantation of spleen tissue is an attempt for maintenance of splenic functions when splenectomy is indicated in children. It minimizes the risks of overwhelming postsplenectomy infection and it has been done in children with severe portal hypertension due to hepatosplenic mansonic schistosomiasis that underwent splenectomy. The purposes of this investigation were to study the morphology of the residual splenic tissue; to evaluate the residual filtration function of this splenosis; and to assess the immune response to polyvalent pneumococcal vaccine of these patients. Twenty-three children with portal hypertension from mansonic schistosomiasis who underwent splenectomy, ligature of the left gastric vein, autotransplantation of spleen tissue into an omental pouch were evaluated for residual splenic parenchyma and functions. Tc-99m sulfur colloid liver-spleen scans were used for detection of splenic nodules. The search for Howell Jolly bodies were used for assessing the filtration function and Enzyme-linked immunosorbent assay was used for measuring the relative rise in titter of specific pneumococcal antibodies. Splenosis was evident in all children; however, in two there were less than five splenic nodules in the greater omentum, which was considered insufficient. Howell-Jolly bodies were found in the peripheral blood only in these two patients with less evident splenosis. The immune response was adequate in 15 patients; it was intermediate in 4 patients and inadequate in 4 patients. Autotransplantation of spleen tissue into an omental pouch is efficient in maintaining the filtration splenic function in more than 90% of the cases and the immune response to pneumococcal vaccination in approximately 65% of the children.

  13. The association between orthostatic hypotension and cognitive state among adults 65 years and older who underwent a comprehensive geriatric assessment

    Science.gov (United States)

    Punchick, Boris; Freud, Tamar; Press, Yan

    2016-01-01

    Abstract The prevalence of cognitive impairment and orthostatic hypotension (OH) increases with age, but the results of studies that assessed possible associations between them are inconsistent. The aim of this study is to assess possible associations between cognitive impairment and OH in patients ≥65 years of age who underwent a comprehensive geriatric assessment. A retrospective analysis was conducted of the computerized medical records of the study population from 2005 to 2013. Data collected included blood pressure measurements that enabled the calculation of OH, results of the mini-mental state examination (MMSE), results of the Montreal cognitive assessment (MoCA) test, and cognitive diagnoses that were determined over the course of the assessment. The rate of OH in the study population of 571 adults was 32.1%. The mean MMSE score was 22.5 ± 5.2 among participants with OH and 21.6 ± 5.8 among those without OH (P = 0.09). The absence of a significant association between OH and MMSE remained after adjusting the MMSE score for age and education level. The mean MoCA score was 16.4 ± 5.0 among participants with OH and 16.4 ± 4.8 among those without (P = 0.33). The prevalence of OH was 39% among participants without cognitive impairment, 28.9% among those with mild cognitive impairment (MCI), and 30.6% among those with dementia (P = 0.13). There was no association between OH and cognitive impairment in adults who underwent a comprehensive geriatric assessment. PMID:27442658

  14. Contralateral prophylactic mastectomy rate and predictive factors among patients with breast cancer who underwent multigene panel testing for hereditary cancer.

    Science.gov (United States)

    Elsayegh, Nisreen; Webster, Rachel D; Gutierrez Barrera, Angelica M; Lin, Heather; Kuerer, Henry M; Litton, Jennifer K; Bedrosian, Isabelle; Arun, Banu K

    2018-05-07

    Although multigene panel testing is increasingly common in patients with cancer, the relationship between its use among breast cancer patients with non-BRCA mutations or variants of uncertain significance (VUS) and disease management decisions has not been well described. This study evaluated the rate and predictive factors of CPM patients who underwent multigene panel testing. Three hundred and fourteen patients with breast cancer who underwent multigene panel testing between 2014 and 2017 were included in the analysis. Of the 314 patients, 70 elected CPM. Election of CPM by gene status was as follows: BRCA carriers (42.3%), non-BRCA carriers (30.1%), and VUS (10.6%). CPM election rates did not differ between non-BRCA carriers and BRCA carriers (P = 0.6205). Among non-BRCA carriers, negative hormone receptor status was associated with CPM (P = 0.0115). For those with a VUS, hormone receptor status was not associated with CPM (P = 0.1879). Although the rate of CPM between BRCA carriers and non-BRCA carriers was not significantly different, the predictors of CPM were different in each group. Our analyses shed the light on the increasing use of CPM among patients who are non-BRCA carriers as well those with a VUS. Our study elucidates the differing predictive factors of CPM election among BRCA carriers, non-BRCA carries, and those with a VUS. Our findings reveal the need for providers to be cognizant that non-BRCA genes and VUS drive women to elect CPM despite the lack of data for contralateral breast cancer risk associated with these genes. © 2018 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  15. Indirect quantum tomography of quadratic Hamiltonians

    Energy Technology Data Exchange (ETDEWEB)

    Burgarth, Daniel [Institute for Mathematical Sciences, Imperial College London, London SW7 2PG (United Kingdom); Maruyama, Koji; Nori, Franco, E-mail: daniel@burgarth.de, E-mail: kmaruyama@riken.jp [Advanced Science Institute, RIKEN, Wako-shi, Saitama 351-0198 (Japan)

    2011-01-15

    A number of many-body problems can be formulated using Hamiltonians that are quadratic in the creation and annihilation operators. Here, we show how such quadratic Hamiltonians can be efficiently estimated indirectly, employing very few resources. We found that almost all the properties of the Hamiltonian are determined by its surface and that these properties can be measured even if the system can only be initialized to a mixed state. Therefore, our method can be applied to various physical models, with important examples including coupled nano-mechanical oscillators, hopping fermions in optical lattices and transverse Ising chains.

  16. Indirect evidence of calcitonin secretion in man.

    Science.gov (United States)

    Caniggia, A; Gennari, C; Vattimo, A; Nardi, P; Nuti, R

    1976-09-01

    1. The effect of calcitonin, a large amount of calcium given orally, pentagastrin and glucagon on plasma 47Ca radioactivity curves in subjects pretreated with 47Ca was examined. 2. A sudden increase of plasma radioactivity after intravenous administration of calcitonin and pentagastrin and after the oral calcium load was observed in normal subjects; the intravenous infusion of glucagon was less effective. 3. Two thyroparathyroidectomized patients who responded to the calcitonin infusion did not respond to the oral calcium load. 4. These data may be considered to offer indirect evidence of endogenous calcitonin secretion in man.

  17. Third European Company Survey – Direct and indirect employee participation

    NARCIS (Netherlands)

    Akkerman, Agnes; Sluiter, Roderick; Jansen, Giedo

    2015-01-01

    This report studies practices in EU establishments for direct and indirect employee participation in decision-making. Indirect employee participation is the involvement of employee representatives in decision-making processes, while direct employee participation describes direct interaction between

  18. Indirect Estimation of Selected Measures of Fertility and Marital ...

    African Journals Online (AJOL)

    DLHS6

    2018-01-09

    Jan 9, 2018 ... marital status distribution data of India especially of the 2011 census in deriving indirectly the fertility measures .... 2011 Census, Economic and Political weekly, EPW Vol. ... Indirect Estimates of Total Fertility Rate Using Child.

  19. Evaluation of Staphylococcus aureus DNA aptamer by enzyme-linked aptamer assay and isothermal titration calorimetry.

    Science.gov (United States)

    Bayraç, Ceren; Öktem, Hüseyin Avni

    2017-02-01

    To monitor the specificity of Staphylococcus aureus aptamer (SA-31) against its target cell, we used enzyme-linked aptamer assay. In the presence of target cell, horseradish peroxidase-conjugated streptavidin bound to biotin-labeled SA-31 showed specific binding to S  aureus among 3 different bacteria with limit of detection of 10 3 colony-forming unit per milliliter. The apparent K a was 1.39 μM -1  ± 0.3 μM -1 . The binding of SA-31 to membrane proteins extracted from cell surface was characterized using isothermal titration calorimetry, and the effect of changes in binding temperature and salt concentrations of binding buffer was evaluated based on thermodynamic parameters (K a , ΔH, and ΔG). Since binding of aptamer to its targets solely depends on its 3-dimensional structure under experimental conditions used in selection process, the change in temperature and ion concentration changed the affinity of SA-31 to its target on surface of bacteria. At 4°C, SA-31 did not show an affinity to its target with poor heat change upon injection of membrane fraction to aptamer solution. However, the apparent association constants of SA-31 slightly varied from K a  = 1.56 μM -1  ± 0.69 μM -1 at 25°C to K a  = 1.03 μM -1  ± 0.9 μM -1 at 37°C. At spontaneously occurring exothermic binding reactions, affinities of S aureus aptamer to its target were also 9.44 μM -1  ± 0.38 μM -1 at 50mM, 1.60 μM -1  ± 0.11 μM -1 at 137mM, and 3.28 μM -1  ± 0.46 μM -1 at 200 mM of salt concentration. In this study, it was demonstrated that enzyme-linked aptamer assay and isothermal titration calorimetry were useful tools for studying the fundamental binding mechanism between a DNA aptamer and its target on the outer surface of S aureus. Copyright © 2016 John Wiley & Sons, Ltd.

  20. THE INDIRECT OBJECT (IO) – ALBANIAN AND ENGLISH

    OpenAIRE

    Shkelqim Millaku; Xhevahire Topanica

    2016-01-01

    The aim of this study is too corporate the function of the indirect object between Albanian and English language. The function and the Albanian typical case for indirect object are dative and ablative. This grammatical phenomena is the full contrast between two languages because in English language doesn’t exist dative and ablative us in Albanian. In Albanian and English language, the indirect object is more heterogenic than the direct object. The indirect (direct) object in both of languages...

  1. On the Relative Size of Direct and Indirect Taxation

    OpenAIRE

    Soldatos, Gerasimos T.

    2014-01-01

    Modifying the standard analytical apparatuses for direct and indirect tax evasion to incorporate forward indirect tax shift in a monopolistically competitive environment, this paper maintains that indirect tax evasion would exceed for sure direct tax evasion only under consumer risk neutrality and a tax policy zeroing the tax shift. Also, in the presence of tax evasion, there cannot be optimal direct-indirect tax mix, because tax evasion is accompanied by uncertainty and hence, nonlinearities...

  2. The determination of the enthalpy of formation and the enthalpy increment of Cd0.5 Te0.5 by Calvet calorimetry

    International Nuclear Information System (INIS)

    Agarwal, R.; Venugopal, V.; Sood, D.D.

    1993-01-01

    In the present study the enthalpy of formation of Cd 0.5 Te 0.5 compound at 785 K were determined from the two elements by direct reaction calorimetry using two different types of set-ups. The enthalpy increment values were measured by drop technique in Calvet calorimetry. (author). 3 refs., 4 tabs

  3. Microdosimetric concepts for indirect radiation reactions

    International Nuclear Information System (INIS)

    Pohlit, W.

    1976-01-01

    It is the aim of microdosimetric models to get information about the influence of microscopic energy deposition by radiation on radiation reactions. Two parameters are always of interest: the energy necessary to produce a certain reaction and the volume in which this energy has to be desposited. In the simple case of an aqueous solution with point targets a complete description of radiation reactions in targets with various concentrations can be given. This model takes into consideration the distinct energy deposition on the particle track, diffusion of radicals and a mean energy necessary for a certain reaction at the target. Typical dose effect curves are obtained which allow the determination of all these quantities from experiments. The model has been tested with the oxydation of iron atoms in aqueous solutions and has been applied for more complex targets such as different alcohols and amino acids. The oxygen consumption in these reactions is used as an easy method for continuous measurement of these indirect reactions. It is the aim of such experiments to get enough quantitative microscopic data on indirect radiation reactions that these reactions can also be followed in living cells

  4. The indirect strategies of internationalization of companies

    Directory of Open Access Journals (Sweden)

    Đorđević Momčilo

    2012-01-01

    Full Text Available The subject of this work are, as mentioned in the title, the indirect strategies of internationalization of companies. The first part talks about the new business environment, the factors that lead to changes and their implications. It is at the same time the business context, which must be taken into consideration that determines the success of companies in the new business environment. In this paper, the emphasis is on company business in international markets, and the selection of appropriate strategies of internationalization, which will be responsible for this new business environment. There are many reasons that are discussed in this paper, and would rather indicate that partners from different countries to accept different strategies, rather than opting for a strategy of export, or a strategy of direct investments abroad. The dynamic technical and technological development, and its universal impact, among other relevant factors, put in the first place the importance of different strategies which is achieved through technology transfer, knowledge and experience whereby the exports, as a classic strategy of involvement in international trade, becomes significantly more difficult. Also, the internationalization of enterprises through direct investment abroad, involves many difficulties related to fitting in a foreign enterprise environment, and a high risk strategy. In addition, there is still a large number of countries do not allow wholly owned foreign enterprises. The paper discusses the value of various indirect internationalization strategy, which may be useful for those domestic companies that are in front of problem the choice of acceptable strategies of internationalization.

  5. Indirect costs of teaching in Canadian hospitals.

    Science.gov (United States)

    MacKenzie, T A; Willan, A R; Cox, M A; Green, A

    1991-01-01

    We sought to determine whether there are indirect costs of teaching in Canadian hospitals. To examine cost differences between teaching and nonteaching hospitals we estimated two cost functions: cost per case and cost per patient-day (dependent variables). The independent variables were number of beds, occupancy rate, teaching ratio (number of residents and interns per 100 beds), province, urbanicity (the population density of the county in which the hospital was situated) and wage index. Within each hospital we categorized a random sample of patient discharges according to case mix and severity of illness using age and standard diagnosis and procedure codes. Teaching ratio and case severity were each highly correlated positively with the dependent variables. The other variables that led to higher costs in teaching hospitals were wage rates and number of beds. Our regression model could serve as the basis of a reimbursement system, adjusted for severity and teaching status, particularly in provinces moving toward introducing case-weighting mechanisms into their payment model. Even if teaching hospitals were paid more than nonteaching hospitals because of the difference in the severity of illness there should be an additional allowance to cover the indirect costs of teaching. PMID:1898870

  6. Cooperation under indirect reciprocity and imitative trust.

    Science.gov (United States)

    Saavedra, Serguei; Smith, David; Reed-Tsochas, Felix

    2010-10-27

    Indirect reciprocity, a key concept in behavioral experiments and evolutionary game theory, provides a mechanism that allows reciprocal altruism to emerge in a population of self-regarding individuals even when repeated interactions between pairs of actors are unlikely. Recent empirical evidence show that humans typically follow complex assessment strategies involving both reciprocity and social imitation when making cooperative decisions. However, currently, we have no systematic understanding of how imitation, a mechanism that may also generate negative effects via a process of cumulative advantage, affects cooperation when repeated interactions are unlikely or information about a recipient's reputation is unavailable. Here we extend existing evolutionary models, which use an image score for reputation to track how individuals cooperate by contributing resources, by introducing a new imitative-trust score, which tracks whether actors have been the recipients of cooperation in the past. We show that imitative trust can co-exist with indirect reciprocity mechanisms up to a threshold and then cooperation reverses -revealing the elusive nature of cooperation. Moreover, we find that when information about a recipient's reputation is limited, trusting the action of third parties towards her (i.e. imitating) does favor a higher collective cooperation compared to random-trusting and share-alike mechanisms. We believe these results shed new light on the factors favoring social imitation as an adaptive mechanism in populations of cooperating social actors.

  7. Cooperation under indirect reciprocity and imitative trust.

    Directory of Open Access Journals (Sweden)

    Serguei Saavedra

    Full Text Available Indirect reciprocity, a key concept in behavioral experiments and evolutionary game theory, provides a mechanism that allows reciprocal altruism to emerge in a population of self-regarding individuals even when repeated interactions between pairs of actors are unlikely. Recent empirical evidence show that humans typically follow complex assessment strategies involving both reciprocity and social imitation when making cooperative decisions. However, currently, we have no systematic understanding of how imitation, a mechanism that may also generate negative effects via a process of cumulative advantage, affects cooperation when repeated interactions are unlikely or information about a recipient's reputation is unavailable. Here we extend existing evolutionary models, which use an image score for reputation to track how individuals cooperate by contributing resources, by introducing a new imitative-trust score, which tracks whether actors have been the recipients of cooperation in the past. We show that imitative trust can co-exist with indirect reciprocity mechanisms up to a threshold and then cooperation reverses -revealing the elusive nature of cooperation. Moreover, we find that when information about a recipient's reputation is limited, trusting the action of third parties towards her (i.e. imitating does favor a higher collective cooperation compared to random-trusting and share-alike mechanisms. We believe these results shed new light on the factors favoring social imitation as an adaptive mechanism in populations of cooperating social actors.

  8. 21 CFR 870.3640 - Indirect pacemaker generator function analyzer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Indirect pacemaker generator function analyzer... Indirect pacemaker generator function analyzer. (a) Identification. An indirect pacemaker generator function analyzer is an electrically powered device that is used to determine pacemaker function or...

  9. System markets: Indirect network effects in action, or inaction?

    NARCIS (Netherlands)

    J.L.G. Binken (Jeroen)

    2010-01-01

    textabstractIn this dissertation, I empirically examine system markets up close. More specifically I examine indirect network effects, both demand-side and supply-side indirect network effects. Indirect network effects are the source of positive feedback in system markets, or so network effect

  10. Direct calorimetry identifies deficiencies in respirometry for the determination of resting metabolic rate in C57Bl/6 and FVB mice

    Science.gov (United States)

    Burnett, Colin M. L.

    2013-01-01

    Substantial research efforts have been aimed at identifying novel targets to increase resting metabolic rate (RMR) as an adjunct approach to the treatment of obesity. Respirometry (one form of “indirect calorimetry”) is unquestionably the dominant technique used in the obesity research field to assess RMR in vivo, although this method relies upon a lengthy list of assumptions that are likely to be violated in pharmacologically or genetically manipulated animals. A “total” calorimeter, including a gradient layer direct calorimeter coupled to a conventional respirometer, was used to test the accuracy of respirometric-based estimations of RMR in laboratory mice (Mus musculus Linnaeus) of the C57Bl/6 and FVB background strains. Using this combined calorimeter, we determined that respirometry underestimates RMR of untreated 9- to 12-wk-old male mice by ∼10–12%. Quantitative and qualitative differences resulted between methods for untreated C57Bl/6 and FVB mice, C57Bl/6 mice treated with ketamine-xylazine anesthesia, and FVB mice with genetic deletion of the angiotensin II type 2 receptor. We conclude that respirometric methods underestimate RMR in mice in a magnitude that is similar to or greater than the desired RMR effects of novel therapeutics. Sole reliance upon respirometry to assess RMR in mice may lead to false quantitative and qualitative conclusions regarding the effects of novel interventions. Increased use of direct calorimetry for the assessment of RMR and confirmation of respirometry results and the reexamination of previously discarded potential obesity therapeutics are warranted. PMID:23964071

  11. 65. Impact of focused echocardiography in clinical decision of patients presented with STMI, underwent primary percutenouse angioplasty

    Directory of Open Access Journals (Sweden)

    M. Qasem

    2016-07-01

    Full Text Available Echocardiography in coronary artery diseases is an essential, routine echocardiography prior to primary percutaneous angioplasty is not clear. In our clinical practice in primary angioplasty we faced lots of complications either before or during or after the procedure. Moreover, lots of incidental findings that discovered after the procedure which if known will affect the plan of management. One-hundred-nineteen consecutive underwent primary angioplasty. All patients underwent FE prior to the procedure in catheterization lab while the patient was preparing for the procedure. FE with 2DE of LV at base, mid and apex, and apical stander views. Diastology grading, E/E′ and color doppler of mitral and aortic valve were performed. (N = 119 case of STMI were enrolled, mean age 51 ± 12 year. Eleven cases (9.2% had normal coronary and normal LV function. Twenty cases (17% of MI complication detected before the procedures: RV infarction 8.4% (5.1% asymptomatic and 3.3% symptomatic, ischemic MR (8.4%, LV apical aneurysm (0.8%, significant pericardial effusion (0.80%. Acute pulmonary edema in 17 cases (14.3%: six cases (5.1% developed acute pulmonary edema on the cath lab with grade 3 diastolic dysfunction and E/E ′  >20, 9 cases (7.6% develop acute pulmonary edema in CCU with grade 2–3 diastolic dysfunction and E/E′ 15–20. 2 cases (2.7% develop acute pulmonary in CCU with grade 1–2 diastolic dysfunction and E/E′ 9–14. One case (0.8% presented cardiac tamponade 2 h post PCI. Incidental finding not related to STMI were as follow: 2 cases (1.7% with severe fibro degenerative MR, 2 cases (1.7% with mild to moderate AR and 2 cases (1.7% with mild to moderate AS. Isoled CABG 5/4.2% and CABG and MVR 2/1.7%. FE play an important role in guiding the management, early detection the incidental findings and complication post PCI.

  12. A study of the use of lead fluoride for electromagnetic calorimetry

    International Nuclear Information System (INIS)

    Woody, C.L.; Kierstead, J.A.; Levy, P.W.; Stoll, S.; Weingarten, A.B.; Anderson, D.F.; Ramberg, E.J.; Kuno, Y.; Macdonald, J.A.; Konaka, A.; Hutcheon, D.A.

    1992-01-01

    A study has been made on the properties of lead fluoride as a Cherenkov material for use in electromagnetic calorimetry. A prototype calorimeter module consisting of a 5 x 5 array of 2.1 x 2.1 x 18.5 cm 3 crystals has been built and tested in a test beam at the Brookhaven AGS. Results are given on energy resolution, shower size and e/π separation for electrons and pions in the range from 1--4 GeV. The light output has been measured to give approx-gt 1000 photoelectrons per MeV in good quality crystals, and to provide useful signals down to as low as 32 MeV. Measurements were also made on radiation damage in lead fluoride using 60 Co gamma rays and high energy ionizing particles, as well as on thermoluminescence after irradiation. It was found that only modest damage occurs up to a level of ∼ 30 Krad in large, calorimeter size crystals, and that the damage can be easily removed by optical bleaching

  13. Ring-shaped Calorimetry Information for a Neural eGamma Identification with ATLAS Detector

    CERN Document Server

    Da Fonseca Pinto, Joao Victor; The ATLAS collaboration; Oliveira Damazio, Denis; Seixas, Jose

    2016-01-01

    \\title{Ring-shaped Calorimetry Information for a Neural e/$\\gamma$ Identification with ATLAS Detector} After the successful operation of the Large Hadron Collider resulting with the discovery of the Higgs boson, a new data-taking period (Run 2) has started. For the first time, collisions are produced with energies of 13 TeV in the centre of mass. It is foreseen the luminosity increase, reaching values as high as $10^{34}cm^{-2}s^{-1}$ yet in 2015. These changes in experimental conditions bring a proper environment for possible new physics key-findings. ATLAS is the largest LHC detector and was designed for general-purpose physics studies. Many potential physics channels have electrons or photons in their final states. For efficient studies on these channels precise measurement and identification of such particles is necessary. The identification task consists of disentangling those particles (signal) from collimated hadronic jets (background). Reported work concerns the identification process based on the cal...

  14. Simultaneous Absorptance and Thermal-Diffusivity Determination of Optical Components with Laser Calorimetry Technique

    Science.gov (United States)

    Wang, Yanru; Li, Bincheng

    2012-11-01

    The laser calorimetry (LCA) technique is used to determine simultaneously the absorptances and thermal diffusivities of optical components. An accurate temperature model, in which both the finite thermal conductivity and the finite sample size are taken into account, is employed to fit the experimental temperature data measured with an LCA apparatus for a precise determination of the absorptance and thermal diffusivity via a multiparameter fitting procedure. The uniqueness issue of the multiparameter fitting is discussed in detail. Experimentally, highly reflective (HR) samples prepared with electron-beam evaporation on different substrates (BK7, fused silica, and Ge) are measured with LCA. For the HR-coated sample on a fused silica substrate, the absorptance is determined to be 15.4 ppm, which is close to the value of 17.6 ppm, determined with a simplified temperature model recommended in the international standard ISO11551. The thermal diffusivity is simultaneously determined via multiparameter fitting to be approximately 6.63 × 10-7 m2 · s-1 with a corresponding square variance of 4.8 × 10-4. The fitted thermal diffusivity is in reasonably good agreement with the literature value (7.5 × 10-7 m2 · s -1). Good agreement is also obtained for samples with BK7 and Ge substrates.

  15. Changes in chromatin structure during the aging of cell cultures as revealed by differential scanning calorimetry

    International Nuclear Information System (INIS)

    Almagor, M.; Cole, R.D.

    1989-01-01

    Nuclei from cultured human cells were examined by differential scanning calorimetry. Their melting profiles revealed four structural transitions at 60, 76, 88, and 105 degrees C (transitions I-IV, respectively). In immortalized (i.e., tumor) cell cultures and in normal cell cultures of low passage number, melting profiles were dominated by the 105 degrees C transition (transition IV), but in vitro aging of normal and Werner syndrome cells was associated with a marked decrease in transition IV followed by an increase in transition III at the expense of transition IV. At intermediate times in the aging process, much DNA melted at a temperature range (95-102 degrees C) intermediate between transitions III and IV, and this is consistent with the notion that aging of cell cultures is accompanied by an increase in single-strand character of the DNA. Calorimetric changes were observed in the melting profile of nuclei from UV-irradiated tumor cells that resembled the age-induced intermediate melting of chromatin. It is suggested that aging is accompanied by an increase in single-stranded character of the DNA in chromatin, which lowers its melting temperature, followed by strand breaks in the DNA that destroy its supercoiling potential

  16. Morphological Investigation into Starch Bio-Nanocomposites via Synchrotron Radiation and Differential Scanning Calorimetry

    Directory of Open Access Journals (Sweden)

    Huihua Liu

    2011-01-01

    Full Text Available We studied a hydrophilic, plasticized bionanocomposite system involving sorbitol plasticizer, amylose biopolymer, and montmorillonite (MMT for the presence of competitive interactions among them at different moisture content. Synchrotron analysis via small angle X-ray scattering (SAXS and thermal analysis using differential scanning calorimetry (DSC were performed to understand crystalline growth and the distribution of crystalline domains within the samples. The SAXS diffraction patterns showed reduced interhelix spacing in the amylose network indicating strong amylose-sorbitol interactions. Depending on the sorbitol and MMT concentration, these interactions also affected the free moisture content and crystalline domains. Domains of around 95 Å and 312 Å were found in the low-moisture-content samples as compared to a single domain of 95 Å in the high-moisture-content samples. DSC measurements confirmed that the MMT increased the onset and the melting temperature of nanocomposites. Moreover, the results showed that the ternary interactions among sorbitol-amylose-MMT supported the crystalline heterogeneity through secondary nucleation.

  17. Synthesized cellulose/succinic anhydride as an ion exchanger. Calorimetry of divalent cations in aqueous suspension

    Energy Technology Data Exchange (ETDEWEB)

    Melo, Julio C.P. [Institute of Chemistry, University of Campinas, UNICAMP, P.O. Box 6154, 13084-971 Campinas, SP (Brazil); Silva Filho, Edson C. [LIMAV, Federal University of Piaui, 64049-550 Teresina, Piaui (Brazil); Santana, Sirlane A.A. [Departamento de Quimica/CCET, Universidade Federal do Maranhao, Av. dos Portugueses S/N, Campus do Bacanga, 65080-540 Sao Luiz, MA (Brazil); Airoldi, Claudio, E-mail: airoldi@iqm.unicamp.br [Institute of Chemistry, University of Campinas, UNICAMP, P.O. Box 6154, 13084-971 Campinas, SP (Brazil)

    2011-09-20

    Highlights: {yields} Synthetic route based on anhydride melting point. {yields} Cellulosic biopolymer/anhydride as ion exchanger. {yields} Calorimetry of cation exchange at solid/liquid interface. {yields} Favorable thermodynamic data of exchanging process. - Abstract: A synthetic route to a biopolymer/anhydride ion exchanger adds cellulose directly to molten succinic anhydride in a quasi solvent-free procedure. An amount of 3.07 {+-} 0.05 mmol of pendant groups incorporated onto the polymeric structure, which was characterized by elemental analysis, solid state carbon NMR, infrared, X-ray and thermogravimetry. The new polysaccharide is able to exchange cations from aqueous solution through a batchwise methodology, to obtain 2.46 {+-} 0.09 mmol g{sup -1} for divalent cobalt and nickel cations. The net thermal effects obtained from calorimetric titrations gave endothermic values of 3.81 {+-} 0.02 and 2.35 {+-} 0.01 kJ mol{sup -1}. The spontaneity of this ion-exchange process reflected in negative Gibbs energies and also a positive entropic contribution. These thermodynamic data at the solid/liquid interface suggests a favorable ion exchange process for this anchored biopolymer, for cation removal from the environment.

  18. Van ‘t Hoff global analyses of variable temperature isothermal titration calorimetry data

    International Nuclear Information System (INIS)

    Freiburger, Lee A.; Auclair, Karine; Mittermaier, Anthony K.

    2012-01-01

    Highlights: ▶ We developed a global fitting strategy for ITC data collected at multiple temperatures. ▶ This method does not require prior knowledge of the binding mechanism. ▶ Monte Carlo simulations show that the approach improves the accuracy of extracted thermodynamic parameters. ▶ The method is used to study coupled folding/binding in aminoglycoside 6′-N-acetyltransferase-Ii. - Abstract: Isothermal titration calorimetry (ITC) can provide detailed information on the thermodynamics of biomolecular interactions in the form of equilibrium constants, K A , and enthalpy changes, ΔH A . A powerful application of this technique involves analyzing the temperature dependences of ITC-derived K A and ΔH A values to gain insight into thermodynamic linkage between binding and additional equilibria, such as protein folding. We recently developed a general method for global analysis of variable temperature ITC data that significantly improves the accuracy of extracted thermodynamic parameters and requires no prior knowledge of the coupled equilibria. Here we report detailed validation of this method using Monte Carlo simulations and an application to study coupled folding and binding in an aminoglycoside acetyltransferase enzyme.

  19. Biomolecule-nanoparticle interactions: Elucidation of the thermodynamics by isothermal titration calorimetry.

    Science.gov (United States)

    Huang, Rixiang; Lau, Boris L T

    2016-05-01

    Nanomaterials (NMs) are often exposed to a broad range of biomolecules of different abundances. Biomolecule sorption driven by various interfacial forces determines the surface structure and composition of NMs, subsequently governs their functionality and the reactivity of the adsorbed biomolecules. Isothermal titration calorimetry (ITC) is a nondestructive technique that quantifies thermodynamic parameters through in-situ measurement of the heat absorption or release associated with an interaction. This review highlights the recent applications of ITC in understanding the thermodynamics of interactions between various nanoparticles (NPs) and biomolecules. Different aspects of a typical ITC experiment that are crucial for obtaining accurate and meaningful data, as well as the strengths, weaknesses, and challenges of ITC applications to NP research were discussed. ITC reveals the driving forces behind biomolecule-NP interactions and the effects of the physicochemical properties of both NPs and biomolecules by quantifying the crucial thermodynamics parameters (e.g., binding stoichiometry, ΔH, ΔS, and ΔG). Complimentary techniques would strengthen the interpretation of ITC results for a more holistic understanding of biomolecule-NP interactions. The thermodynamic information revealed by ITC and its complimentary characterizations is important for understanding biomolecule-NP interactions that are fundamental to the biomedical and environmental applications of NMs and their toxicological effects. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Enzymatic hydrolysis of Amaranth flour - differential scanning calorimetry and scanning electron microscopy studies

    Energy Technology Data Exchange (ETDEWEB)

    Barba de la Rosa, A.P.; Paredes-Lopez, O.; Carabez-Trejo, A.; Ordorica-Falomir, C. (Instituto Politecnico Nacional, Irapuato (Mexico). Centro de Investigacion y de Estudios Avanzados)

    1989-11-01

    High-protein amaranth flour (HPAF) and carbohydrate rich fraction (CRF) were produced from raw flour in a single-step process using a heat-stable alpha-amylase preparation. Protein content of flour increased from 15 to about 30 or 39% at liquefaction temperatures of 70 or 90{sup 0}C, respectively and 30 min hydrolysis time. CRF exhibited 14-22 DE. Enzymatic action at 70{sup 0}C increased endotherm temperature and gelatinization enthalpy of HPAF, in relation to gelatinized flour, as assessed by differential scanning calorimetry (DSC). Hydrolysis at 90{sup 0}C did not affect significantly (P > 0.05) DSC peak temperature. It is suggested that these changes in DSC performance might result from differences in amount and type of low-molecular weight carbohydrates and residual starch. Scanning electron microscopy (SEM) demonstrated that hydrolysis temperature changed substantially the structural appearance of flour particles. HPAF and CRF might find applications as dry milk extender and sweetener, respectively. (orig.).

  1. Uptake and release protocol for assessing membrane binding and permeation by way of isothermal titration calorimetry.

    Science.gov (United States)

    Tsamaloukas, Alekos D; Keller, Sandro; Heerklotz, Heiko

    2007-01-01

    The activity of many biomolecules and drugs crucially depends on whether they bind to biological membranes and whether they translocate to the opposite lipid leaflet and trans aqueous compartment. A general strategy to measure membrane binding and permeation is the uptake and release assay, which compares two apparent equilibrium situations established either by the addition or by the extraction of the solute of interest. Only solutes that permeate the membrane sufficiently fast do not show any dependence on the history of sample preparation. This strategy can be pursued for virtually all membrane-binding solutes, using any method suitable for detecting binding. Here, we present in detail one example that is particularly well developed, namely the nonspecific membrane partitioning and flip-flop of small, nonionic solutes as characterized by isothermal titration calorimetry. A complete set of experiments, including all sample preparation procedures, can typically be accomplished within 2 days. Analogous protocols for studying charged solutes, virtually water-insoluble, hydrophobic compounds or specific ligands are also considered.

  2. Differential scanning calorimetry method for purity determination: A case study on polycyclic aromatic hydrocarbons and chloramphenicol

    International Nuclear Information System (INIS)

    Kestens, V.; Zeleny, R.; Auclair, G.; Held, A.; Roebben, G.; Linsinger, T.P.J.

    2011-01-01

    Highlights: → Purity assessment of polycyclic aromatic hydrocarbons and chloramphenicol by DSC. → DSC results compared with traditional purity methods. → Different methods give different results, multiple method approach recommended. → DSC sensitive to impurities that have similar structures as main component. - Abstract: In this study the validity and suitability of differential scanning calorimetry (DSC) to determine the purity of selected polycyclic aromatic hydrocarbons and chloramphenicol has been investigated. The study materials were two candidate certified reference materials (CRMs), 6-methylchrysene and benzo[a]pyrene, and two different batches of commercially available highly pure chloramphenicol. The DSC results were compared with those obtained by other methods, namely gas and liquid chromatography with mass spectrometric detection, liquid chromatography with diode array detection, and quantitative nuclear magnetic resonance. The purity results obtained by these different analytical methods confirm the well-known challenges of comparing results of different method-defined measurands. In comparison with other methods, DSC has a much narrower working range. This limits the applicability of DSC as purity determination method, for instance during the assignment of the purity value of a CRM. Nevertheless, this study showed that DSC can be a powerful technique to detect impurities that are structurally very similar to the main purity component. From this point of view, and because of its good repeatability, DSC can be considered as a valuable technique to investigate the homogeneity and stability of candidate purity CRMs.

  3. PHARMACEUTICAL AMORPHOUS ORGANIC MATERIALS CHARACTERIZATION BY USING THE DIFFERENTIAL SCANNING CALORIMETRY AND DYNAMIC MECHANICAL ANALYSIS

    Directory of Open Access Journals (Sweden)

    Ion Dranca

    2011-12-01

    Full Text Available This research has been carried out in order to demonstrate the use of differential scanning calorimetry (DSC in detecting and measuring α- and β-relaxation processes in amorphous pharmaceutical systems. DSC has been employed to study amorphous samples of poly (vinylpyrrolidone (PVP, indomethacin (InM, and ursodeoxycholic acid (UDA that are annealed at temperature (Ta around 0.8 of their glass transition temperature (Tg. Dynamic mechanical analysis (DMA is used to measure β- relaxation in PVP. Yet, the DSC has been used to study the glassy indomethacin aged at 0 and -10 oC for periods of time up to 109 and 210 days respectively. The results demonstrate the emergence of a small melting peak of the α-polymorph after aging for 69 days at 0°C and for 147 days at -10°C (i.e., ~55°C below the glass transition temperature that provides evidence of nucleation occurring in the temperature region of the β-relaxation.

  4. Investigation of phase transformations in ductile cast iron of differential scanning calorimetry

    International Nuclear Information System (INIS)

    Przeliorz, R; Piatkowski, J

    2011-01-01

    The effect of heating rate on phase transformations to austenite range in ductile cast iron of the EN-GJS-450-10 grade was investigated. For studies of phase transformations, the technique of differential scanning calorimetry (DSC) was used. Micro structure was examined by optical microscopy. The calorimetric examinations have proved that on heating three transformations occur in this grade of ductile iron, viz. magnetic transformation at the Curie temperature, pearlite→austenite transformation and ferrite→austenite transformation. An increase in the heating rate shifts the pearlite→austenite and ferrite→austenite transformations to higher temperature range. At the heating rate of 5 and 15 deg. C min -1 , local extrema have been observed to occur: for pearlite→austenite transformation at 784 deg. C and 795 deg. C, respectively, and for ferrite+ graphite →austenite transformation at 805 deg. C and 821 deg. C, respectively. The Curie temperature of magnetic transformation was extrapolated to a value of 740 deg. C. Each transformation is related with a specific thermal effect. The highest value of enthalpy is accompanying the ferrite→austenite transformation, the lowest occurs in the case of pearlite→austenite transformation.

  5. Structure of water in mesoporous organosilica by calorimetry and inelastic neutron scattering

    Science.gov (United States)

    Levy, Esthy; Kolesnikov, Alexander I.; Li, Jichen; Mastai, Yitzhak

    2009-01-01

    In this paper, we describe the preparation of mesoporous organosilica samples with hydrophilic or hydrophobic organic functionality inside the silica channel. We synthesized mesoporous organosilica of identical pore sizes based on two different organic surface functionality namely hydrophobic (based on octyltriethoxysilane OTES) and hydrophilic (3-aminopropyltriethoxysilane ATES) and MCM-41 was used as a reference system. The structure of water/ice in those porous silica samples have been investigated over a range temperatures by differential scanning calorimetry (DSC) and inelastic neutron scattering (INS). INS study revealed that water confined in hydrophobic mesoporous organosilica shows vibrational behavior strongly different than bulk water. It consists of two states: water with strong and weak hydrogen bonds (with ratio 1:2.65, respectively), compared to ice-Ih. The corresponding O-O distances in these water states are 2.67 and 2.87 Ǻ, which strongly differ compared to ice-Ih (2.76 Ǻ). INS spectra for water in hydrophilic mesoporous organosilica ATES show behavior similar to bulk water, but with greater degree of disorder.

  6. Challenges of the Usual Graphical Methods Used to Characterize Phase Change Materials by Differential Scanning Calorimetry

    Directory of Open Access Journals (Sweden)

    Stéphane Gibout

    2018-01-01

    Full Text Available Modeling the thermal behavior of a plant or devices using Phase Change Materials (PCM requires to know their thermophysical properties. The Differential Scanning Calorimetry (DSC is a technic largely used to investigate them. However, under the pretext to experiment with small samples, some authors consider the DSC curves as directly representing the properties of the materials without realizing that this interpretation is very often incompatible with the thermodynamics laws: as an example, although a pure substance melts at a fixed temperature T F , it is proposed a melting through a temperature range higher than T F and depending on the experiments (heating rates, sample masses..., for solutions the suggested characteristic temperatures are incompatible with the phase diagram, and also a hysteresis phenomenon is invented... In this paper, we demonstrate by a model coupling thermodynamics and conduction heat transfers, that the DSC curves are exactly compatible with the thermodynamics of phase changes (melting at fixed temperature for pure substances, in conformity with phase diagrams for solutions.... The cases of pure substances, saline solutions, substances with impurities or solid solutions are detailed. We indicate which information can, however, be given by the curves. We also propose a more sophisticated method by inverse calculations to determine the specific enthalpy whose all the thermodynamical properties can be deduced. Finally, we give some indications to understand and use the results indicating supercooling.

  7. Enthalpies of formation of UAl1 and UAl3 by calorimetry

    International Nuclear Information System (INIS)

    Nagarajan, K.; Babu, R.; Mathews, C.K.

    1993-01-01

    Enthalpies of formation of the intermetallic compounds UAl 4 and UAl 3 at 298.15 K were determined by high temperature solution calorimetry in which liquid aluminium was used as the solvent. The thermal effects of dissolution of UAl 4 , UAl 3 and U in liquid aluminium were measured in separate experiments by dropping the samples held at the ambient temperature into liquid aluminium maintained at 980 K in the calorimeter. The thermal effects of dissolution of these samples at infinite dilution in liquid aluminium were derived from these measurements and based on this data the enthalpies of formation of UAl 4 and UAl 3 at 298.15 K were computed. The values obtained are ΔH f,298.15 (UAl 4 )=-126.5±13.3 kJ mol -1 and ΔH f,298.15 (UAl 3 )=-118.1±8.2 kJ mol -1 . The integral enthalpies of formation of U-Al alloys at 978 K, 1078 K and 1094 K were measured by dropping U samples maintained at the ambient temperature into liquid aluminium in the calorimeter at the experimental temperature. From the integral enthalpies of formation of U-Al alloys in the two phase regions, {U-Al}+ 4 > and {U-Al}+ 3 >, the enthalpies of formation of UAl 4 and UAl 3 , respectively, at the temperatures of measurement were derived. These results are discussed in comparison with the literature data. (orig.)

  8. Calorimetry Minisensor for the Localised Measurement of Surface Heat Dissipated from the Human Body.

    Science.gov (United States)

    Socorro, Fabiola; Rodríguez de Rivera, Pedro Jesús; Rodríguez de Rivera, Manuel

    2016-11-06

    We have developed a calorimetry sensor that can perform a local measurement of the surface heat dissipated from the human body. The operating principle is based on the law of conductive heat transfer: heat dissipated by the human body passes across a thermopile located between the individual and a thermostat. Body heat power is calculated from the signals measured by the thermopile and the amount of power dissipated across the thermostat in order to maintain a constant temperature. The first prototype we built had a detection area measuring 6 × 6 cm², while the second prototype, which is described herein, had a 2 × 2 cm² detection area. This new design offers three advantages over the initial one: (1) greater resolution and three times greater thermal sensitivity; (2) a twice as fast response; and (3) it can take measurements from smaller areas of the body. The sensor has a 5 mW resolution, but the uncertainty is greater, up to 15 mW, due to the measurement and calculation procedure. The order of magnitude of measurements made in healthy subjects ranged from 60 to 300 mW at a thermostat temperature of 28 °C and an ambient room temperature of 21 °C. The values measured by the sensor depend on the ambient temperature and the thermostat's temperature, while the power dissipated depends on the individual's metabolism and any physical and/or emotional activity.

  9. Structural domains and conformational changes in nuclear chromatin: a quantitative thermodynamic approach by differential scanning calorimetry.

    Science.gov (United States)

    Balbi, C; Abelmoschi, M L; Gogioso, L; Parodi, S; Barboro, P; Cavazza, B; Patrone, E

    1989-04-18

    A good deal of information on the thermodynamic properties of chromatin was derived in the last few years from optical melting experiments. The structural domains of the polynucleosomal chain, the linker, and the core particle denature as independent units. The differential scanning calorimetry profile of isolated chromatin is made up of three endotherms, at approximately 74, 90, and 107 degrees C, having an almost Gaussian shape. Previous work on this matter, however, was mainly concerned with the dependence of the transition enthalpy on external parameters, such as the ionic strength, or with the melting of nuclei from different sources. In this paper we report the structural assignment of the transitions of rat liver nuclei, observed at 58, 66, 75, 92, and 107 degrees C. They are representative of the quiescent state of the cell. The strategy adopted in this work builds on the method developed for the investigation of complex biological macromolecules. The heat absorption profile of the nucleus was related to the denaturation of isolated nuclear components; electron microscopy and electrophoretic techniques were used for their morphological and molecular characterization. The digestion of chromatin by endogenous nuclease mimics perfectly the decondensation of the higher order structure and represented the source of several misinterpretations. This point was carefully examined in order to define unambiguously the thermal profile of native nuclei. The low-temperature transitions, centered around 58 and 66 degrees C, arise from the melting of scaffolding structures and of the proteins associated with heterogeneous nuclear RNA.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. Beam Studies of the Segmented Resistive WELL: a Potential Thin Sampling Element for Digital Hadron Calorimetry

    CERN Document Server

    Arazi, Lior; Breskin, Amos; Bressler, Shikma; Moleri, Luca; Natal da Luz, Hugo; Oliveri, Eraldo; Pitt, Michael; Rubin, Adam; Marques Ferreira dos Santos, Joaquim; Calapez Albuquerque Veloso, João Filipe; White, Andrew Paul

    2013-01-01

    Thick Gas Electron Multipliers (THGEMs) have the potential of constituting thin, robust sampling elements in Digital Hadron Calorimetry (DHCAL) in future colliders. We report on recent beam studies of new single- and double-THGEM-like structures; the multiplier is a Segmented Resistive WELL (SRWELL) - a single-faced THGEM in contact with a segmented resistive layer inductively coupled to readout pads. Several 10$\\times$10 cm$^2$ configurations with a total thickness of 5-6 mm (excluding electronics) with 1 cm$^2$ pads coupled to APV-SRS readout were investigated with muons and pions. Detection efficiencies in the 98$%$ range were recorded with average pad-multiplicity of $\\sim$1.1. The resistive anode resulted in efficient discharge damping, with potential drops of a few volts; discharge probabilities were $\\sim10^{-7}$ for muons and $\\sim10^{-6}$ for pions in the double-stage configuration, at rates of a few kHz/cm$^2$. Further optimization work and research on larger detectors are underway.

  11. Thermodynamic study of the interaction between calcium and zoledronic acid by calorimetry

    International Nuclear Information System (INIS)

    Mostefa Side Larbi, Mohamed A.; Sauzet, Christophe; Piccerelle, Philippe; Cau, Pierre

    2016-01-01

    Bisphosphonates (BPs) are widely used to treat calcium disorders because of their structural and functional similarities with the organic pyrophosphates present in plasma and urine. BPs are well known for their strong interactions with calcium, and they have been shown to bind to hydroxyapatite or bone; however, no model exists for studying in greater detail how BPs and particularly amino-bisphosphonates (N-BPs) such as zolendronate (Zol) bind to free calcium. The aim of this work was to determine the effect of pH on Ca 2+ /Zol complex formation using isothermal titration calorimetry (ITC) because these effects might have important implications for the future development of a solid dosage form. In this study, using a predictive model, we can observe, the existence of three Ca 2+ /Zol complexes. Knowledge of the binding constant for each complex is helpful for predicting the predominance of the different species at different Ca 2+ /Zol ratios. Binding is due to ionic interaction between Ca 2+ and the negative charges formed by dissociated Zol as a function of the pKa. Ca 2+ fixation induces a strong rearrangement of the surrounding water molecules and causes proton release or uptake. The pH-dependent affinity of calcium for each site based on the model used in this work is proposed in detail, which might facilitate the development of new bisphosphonates and enable further elucidation of their mode of action.

  12. Phosphate sorption by three potential filter materials as assessed by isothermal titration calorimetry.

    Science.gov (United States)

    Lyngsie, Gry; Penn, Chad J; Hansen, Hans C B; Borggaard, Ole K

    2014-10-01

    Phosphorus eutrophication of lakes and streams, coming from drained farmlands, is a serious problem in areas with intensive agriculture. Installation of phosphate (P) sorbing filters at drain outlets may be a solution. The aim of this study was to improve the understanding of reactions involved in P sorption by three commercial P sorbing materials, i.e. Ca/Mg oxide-based Filtralite-P, Fe oxide-based CFH-12 and Limestone in two particle sizes (2-1 mm and 1-0.5 mm), by means of isothermal titration calorimetry (ITC), sorption isotherms, sequential extractions and SEM-EDS. The results indicate that P retention by CFH is due to surface complexation by rapid formation of strong Fe-P bonds. In contrast, retention of P by Filtralite-P and Limestone strongly depends on pH and time and is interpreted due to formation of calcium phosphate precipitate(s). Consequently, CFH can unambiguously be recommended as P retention filter material in drain outlets, whereas the use of Filtralite-P and Limestone has certain (serious) limitations. Thus, Filtralite-P has high capacity to retain P but only at alkaline pH (pH ≥ 10) and P retention by Limestone requires long-time contact and a high ratio between sorbent and sorbate. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. A survey of the year 2007 literature on applications of isothermal titration calorimetry.

    Science.gov (United States)

    Bjelić, Sasa; Jelesarov, Ilian

    2008-01-01

    Elucidation of the energetic principles of binding affinity and specificity is a central task in many branches of current sciences: biology, medicine, pharmacology, chemistry, material sciences, etc. In biomedical research, integral approaches combining structural information with in-solution biophysical data have proved to be a powerful way toward understanding the physical basis of vital cellular phenomena. Isothermal titration calorimetry (ITC) is a valuable experimental tool facilitating quantification of the thermodynamic parameters that characterize recognition processes involving biomacromolecules. The method provides access to all relevant thermodynamic information by performing a few experiments. In particular, ITC experiments allow to by-pass tedious and (rarely precise) procedures aimed at determining the changes in enthalpy and entropy upon binding by van't Hoff analysis. Notwithstanding limitations, ITC has now the reputation of being the "gold standard" and ITC data are widely used to validate theoretical predictions of thermodynamic parameters, as well as to benchmark the results of novel binding assays. In this paper, we discuss several publications from 2007 reporting ITC results. The focus is on applications in biologically oriented fields. We do not intend a comprehensive coverage of all newly accumulated information. Rather, we emphasize work which has captured our attention with originality and far-reaching analysis, or else has provided ideas for expanding the potential of the method. Copyright (c) 2008 John Wiley & Sons, Ltd.

  14. High throughput integrated thermal characterization with non-contact optical calorimetry

    Science.gov (United States)

    Hou, Sichao; Huo, Ruiqing; Su, Ming

    2017-10-01

    Commonly used thermal analysis tools such as calorimeter and thermal conductivity meter are separated instruments and limited by low throughput, where only one sample is examined each time. This work reports an infrared based optical calorimetry with its theoretical foundation, which is able to provide an integrated solution to characterize thermal properties of materials with high throughput. By taking time domain temperature information of spatially distributed samples, this method allows a single device (infrared camera) to determine the thermal properties of both phase change systems (melting temperature and latent heat of fusion) and non-phase change systems (thermal conductivity and heat capacity). This method further allows these thermal properties of multiple samples to be determined rapidly, remotely, and simultaneously. In this proof-of-concept experiment, the thermal properties of a panel of 16 samples including melting temperatures, latent heats of fusion, heat capacities, and thermal conductivities have been determined in 2 min with high accuracy. Given the high thermal, spatial, and temporal resolutions of the advanced infrared camera, this method has the potential to revolutionize the thermal characterization of materials by providing an integrated solution with high throughput, high sensitivity, and short analysis time.

  15. Calorimetry using organic scintillators, 'a sideways perspective'.

    Energy Technology Data Exchange (ETDEWEB)

    Proudfoot, J.

    1999-09-10

    Over the last two decades, calorimetry baaed on organic scintillators has developed into an excellent technology for many experimental situations in high energy physics. The primary difficulty, that of extracting the light signals, has benefited from two milestone innovations. The first was the use of wavelength-shifting bars to allow light to be efficiently collected from large areas of scintillator and then readily piped to a readout device. The second of these was the extension of this approach to plastic wavelength-shifting optical fibers whose great flexibility and small diameter allowed a minimum of detector volume to be compromised by the read-out. These two innovations coupled with inventiveness have produced many varied and successful calorimeters. Equal response to both hadronic and electromagnetic showers can be realized in scintillator-based calorimeters. However, in general this is not the case and it is likely that in the search for greater performance, in the future, combined tracking and calorimeter systems will be required.

  16. Titration calorimetry of anesthetic-protein interaction: negative enthalpy of binding and anesthetic potency.

    Science.gov (United States)

    Ueda, I; Yamanaka, M

    1997-04-01

    Anesthetic potency increases at lower temperatures. In contrast, the transfer enthalpy of volatile anesthetics from water to macromolecules is usually positive. The transfer decreases at lower temperature. It was proposed that a few selective proteins bind volatile anesthetics with negative delta H, and these proteins are involved in signal transduction. There has been no report on direct estimation of binding delta H of anesthetics to proteins. This study used isothermal titration calorimetry to analyze chloroform binding to bovine serum albumin. The calorimetrically measured delta H cal was -10.37 kJ.mol-1. Thus the negative delta H of anesthetic binding is not limited to signal transduction proteins. The binding was saturable following Fermi-Dirac statistics and is characterized by the Langmuir adsorption isotherms, which is interfacial. The high-affinity association constant, K, was 2150 +/- 132 M-1 (KD = 0.47 mM) with the maximum binding number, Bmax = 3.7 +/- 0.2. The low-affinity K was 189 +/- 3.8 M-1 (KD = 5.29 mM), with a Bmax of 13.2 +/- 0.3. Anesthetic potency is a function of the activity of anesthetic molecules, not the concentration. Because the sign of delta H determines the temperature dependence of distribution of anesthetic molecules, it is irrelevant to the temperature dependence of anesthetic potency.

  17. The Enthalpy of Decomposition of Hydrogen Peroxide: A General Chemistry Calorimetry Experiment

    Science.gov (United States)

    Marzzacco, Charles J.

    1999-11-01

    A calorimetry experiment involving the catalytic decomposition of aqueous hydrogen peroxide is presented. The experiment is simple, inexpensive, and colorful. In its simplest form, it can be performed in less than one hour; therefore, it is quite suitable for high school labs, which often have time restrictions. The chemicals required are household or commercial 3% H2O2(aq) and 0.50 M Fe(NO3)3(aq). Styrofoam cup calorimeters and thermometers with a range from 20 to 50 oC are also required. Ideally, the thermometers should be precise to 0.01 oC. The temperature of the H2O2 solution is monitored before and after the Fe(NO3)3 catalyst is added. The addition of the catalyst results in a color change and the evolution of heat and bubbles of oxygen. At the conclusion of the reaction, the color of the reaction mixture returns to that of the original Fe(NO3)3 solution. The heat change for the reaction is determined from the temperature change, the specific heat of the solution, and the calorimeter constant. The experimental enthalpy change for the reaction is in excellent agreement with the literature value.

  18. Recent advances and potential applications of modulated differential scanning calorimetry (mDSC) in drug development.

    Science.gov (United States)

    Knopp, Matthias Manne; Löbmann, Korbinian; Elder, David P; Rades, Thomas; Holm, René

    2016-05-25

    Differential scanning calorimetry (DSC) is frequently the thermal analysis technique of choice within preformulation and formulation sciences because of its ability to provide detailed information about both the physical and energetic properties of a substance and/or formulation. However, conventional DSC has shortcomings with respect to weak transitions and overlapping events, which could be solved by the use of the more sophisticated modulated DSC (mDSC). mDSC has multiple potential applications within the pharmaceutical field and the present review provides an up-to-date overview of these applications. It is aimed to serve as a broad introduction to newcomers, and also as a valuable reference for those already practising in the field. Complex mDSC was introduced more than two decades ago and has been an important tool for the quantification of amorphous materials and development of freeze-dried formulations. However, as discussed in the present review, a number of other potential applications could also be relevant for the pharmaceutical scientist. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Application of TZERO calibrated modulated temperature differential scanning calorimetry to characterize model protein formulations.

    Science.gov (United States)

    Badkar, Aniket; Yohannes, Paulos; Banga, Ajay

    2006-02-17

    The objective of this study was to evaluate the feasibility of using T(ZERO) modulated temperature differential scanning calorimetry (MDSC) as a novel technique to characterize protein solutions using lysozyme as a model protein and IgG as a model monoclonal antibody. MDSC involves the application of modulated heating program, along with the standard heating program that enables the separation of overlapping thermal transitions. Although characterization of unfolding transitions for protein solutions requires the application of high sensitive DSC, separation of overlapping transitions like aggregation and other exothermic events may be possible only by use of MDSC. A newer T(ZERO) calibrated MDSC model from TA instruments that has improved sensitivity than previous models was used. MDSC analysis showed total, reversing and non-reversing heat flow signals. Total heat flow signals showed a combination of melting endotherms and overlapping exothermic events. Under the operating conditions used, the melting endotherms were seen in reversing heat flow signal while the exothermic events were seen in non-reversing heat flow signal. This enabled the separation of overlapping thermal transitions, improved data analysis and decreased baseline noise. MDSC was used here for characterization of lysozyme solutions, but its feasibility for characterizing therapeutic protein solutions needs further assessment.

  20. Building a Graphite Calorimetry System for the Dosimetry of Therapeutic X-ray Beams

    Directory of Open Access Journals (Sweden)

    In Jung Kim

    2017-06-01

    Full Text Available A graphite calorimetry system was built and tested under irradiation. The noise level of the temperature measurement system was approximately 0.08 mK (peak to peak. The temperature of the core part rose by approximately 8.6 mK at 800 MU (monitor unit for 6-MV X-ray beams, and it increased as X-ray energy increased. The temperature rise showed less spread when it was normalized to the accumulated charge, as measured by an external monitoring chamber. The radiation energy absorbed by the core part was determined to have values of 0.798 J/μC, 0.389 J/μC, and 0.352 J/μC at 6 MV, 10 MV, and 18 MV, respectively. These values were so consistent among repeated runs that their coefficient of variance was less than 0.15%.

  1. Application of Differential Scanning Calorimetry (DSC in study of phase transformations in ductile iron

    Directory of Open Access Journals (Sweden)

    R. Przeliorz

    2010-04-01

    Full Text Available The effect of heating rate on phase transformations to austenite range in ductile iron of the EN-GJS-450-10 grade was investigated. For studies of phase transformations, the technique of differential scanning calorimetry (DSC was used. Microstructure was examined by optical microscopy. The calorimetric examinations have proved that on heating three transformations occur in this grade of ductile iron, viz. magnetic transformation at the Curie temperature, pearlite→austenite transformation and ferrite→austenite transformation. An increase in the heating rate shifts the pearlite→austenite and ferrite→austenite transformations to higher temperature range. At the heating rate of 5 and 15°C/min, local extrema have been observed to occur: for pearlite→austenite transformation at 784°C and 795°C, respectively, and for ferrite→austenite transformation at 805°C and 821°C, respectively. The Curie temperature of magnetic transformation was extrapolated to a value of 740°C. Each transformation is related with a specific thermal effect. The highest value of enthalpy is accompanying the ferrite→austenite transformation, the lowest occurs in the case of pearlite→austenite transformation.

  2. Thermodynamic analysis of Bacillus subtilis endospore protonation using isothermal titration calorimetry

    Science.gov (United States)

    Harrold, Zoë R.; Gorman-Lewis, Drew

    2013-05-01

    Bacterial proton and metal adsorption reactions have the capacity to affect metal speciation and transport in aqueous environments. We coupled potentiometric titration and isothermal titration calorimetry (ITC) analyses to study Bacillus subtilis spore-proton adsorption. We modeled the potentiometric data using a four and five-site non-electrostatic surface complexation model (NE-SCM). Heats of spore surface protonation from coupled ITC analyses were used to determine site specific enthalpies of protonation based on NE-SCMs. The five-site model resulted in a substantially better model fit for the heats of protonation but did not significantly improve the potentiometric titration model fit. The improvement observed in the five-site protonation heat model suggests the presence of a highly exothermic protonation reaction circa pH 7 that cannot be resolved in the less sensitive potentiometric data. From the log Ks and enthalpies we calculated corresponding site specific entropies. Log Ks and site concentrations describing spore surface protonation are statistically equivalent to B. subtilis cell surface protonation constants. Spore surface protonation enthalpies, however, are more exothermic relative to cell based adsorption suggesting a different bonding environment. The thermodynamic parameters defined in this study provide insight on molecular scale spore-surface protonation reactions. Coupled ITC and potentiometric titrations can reveal highly exothermic, and possibly endothermic, adsorption reactions that are overshadowed in potentiometric models alone. Spore-proton adsorption NE-SCMs derived in this study provide a framework for future metal adsorption studies.

  3. A Universal Method for Fishing Target Proteins from Mixtures of Biomolecules using Isothermal Titration Calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, X.; Sun, Q; Kini, R; Sivaraman, J

    2008-01-01

    The most challenging tasks in biology include the identification of (1) the orphan receptor for a ligand, (2) the ligand for an orphan receptor protein, and (3) the target protein(s) for a given drug or a lead compound that are critical for the pharmacological or side effects. At present, several approaches are available, including cell- or animal-based assays, affinity labeling, solid-phase binding assays, surface plasmon resonance, and nuclear magnetic resonance. Most of these techniques are not easy to apply when the target protein is unknown and the compound is not amenable to labeling, chemical modification, or immobilization. Here we demonstrate a new universal method for fishing orphan target proteins from a complex mixture of biomolecules using isothermal titration calorimetry (ITC) as a tracking tool. We took snake venom, a crude mixture of several hundred proteins/peptides, as a model to demonstrate our proposed ITC method in tracking the isolation and purification of two distinct target proteins, a major component and a minor component. Identities of fished out target proteins were confirmed by amino acid sequencing and inhibition assays. This method has the potential to make a significant advancement in the area of identifying orphan target proteins and inhibitor screening in drug discovery and characterization.

  4. Microchip-calorimetry of organic charge transfer complex which shows superconductivity at low temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Muraoka, Yuki [Department of Chemistry, Graduate School of Science, Osaka University, Machikaneyama 1-1, Toyonaka, Osaka 560-0043 (Japan); Yamashita, Satoshi [RIKEN, Hirosawa 2-1, Wako, Saitama 351-0198 (Japan); Yamamoto, Takashi [Department of Chemistry, Graduate School of Science, Osaka University, Machikaneyama 1-1, Toyonaka, Osaka 560-0043 (Japan); Nakazawa, Yasuhiro, E-mail: nakazawa@chem.sci.osaka-u.ac.jp [Department of Chemistry, Graduate School of Science, Osaka University, Machikaneyama 1-1, Toyonaka, Osaka 560-0043 (Japan); Institute for Molecular Science, Nishigonaka 38, Myodaiji, Okazaki 444-8585 (Japan)

    2012-03-20

    Highlights: Black-Right-Pointing-Pointer Organic charge transfer salt of {kappa}-(BEDT-TTF){sub 2}Cu[N(CN){sub 2}]Br shows superconductivity. Black-Right-Pointing-Pointer We succeeded to detect thermal anomaly microchip device TCG3880. Black-Right-Pointing-Pointer Development details of the calorimeter and the detection system is presented. Black-Right-Pointing-Pointer The magnetic fields dependence shows typical character of layered superconductor. - Abstract: We carried out thermodynamic measurements of organic charge transfer complex of {kappa}-(BEDT-TTF){sub 2}Cu[N(CN){sub 2}]Br, where BEDT-TTF is bis(ethylenedithio)tetrathiafulvalene by TCG3880 chip device in order to examine capability of the chip calorimeter at low temperature region and under magnetic fields. TCG3880 chip is mounted on a {sup 3}He cryostat available in combination with a superconductive magnet up to 7 T. Thermal anomalies related to the glass-like freezing of ethylene groups of BEDT-TTF molecules and the superconductive transition were observed. A frequency dependence of the thermal anomaly of the glass formation and a magnetic fields dependence of the thermal anomaly of the superconductive transition are reported. The results presented in this work demonstrate that the TCG3880 is quite useful for thermodynamic investigations of the organic charge transfer complex with much reduced sample quantity as compared with those of relaxation and adiabatic calorimetry.

  5. Studies on sampling and homogeneous dual readout calorimetry with meta-crystals

    CERN Document Server

    Mavromanolakis, G; Lecoq, P

    2011-01-01

    The meta-crystals concept is an approach that consists of using both undoped and properly doped heavy crystal fibers of identical material as the active medium of a calorimeter. The undoped fibers behave as Cherenkov radiators while the doped ones behave as scintillators. A dual readout calorimeter can be built with its sensitive volume composed of a mixture of both types of crystals. In addition if the calorimeter is adequately finely segmented it can also function as a particle flow calorimeter at the same time. In this way one could possibly combine the advantages of both the particle flow concept and the dual readout scheme. We discuss the approach of dual readout calorimetry with meta-crystals made of Lutetium Aluminium Garnet (LuAG). We brie fly present studies on the material development and first testbeam activities and then focus on performance expectation studies based on simulation. We discuss in more detail the results from generic systematic scannings of the design parameters of a dual readout ca...

  6. AC Calorimetry and Thermophysical Properties of Bulk Glass-Forming Metallic Liquids

    Science.gov (United States)

    Johnson, William L.

    2000-01-01

    Thermo-physical properties of two bulk metallic glass forming alloys, Ti34Zr11Cu47Ni8 (VIT 101) and Zr57Nb5Ni12.6Al10CU15.4 (VIT 106), were investigated in the stable and undercooled melt. Our investigation focused on measurements of the specific heat in the stable and undercooled liquid using the method of AC modulation calorimetry. The VIT 106 exhibited a maximum undercooling of 140 K in free radiative cooling. Specific heat measurements could be performed in stable melt down to an undercooling of 80 K. Analysis of the specific heat data indicate an anomaly near the equilibrium liquidus temperature. This anomaly is also observed in y the temperature dependencies of the external relaxation time, the specific volume, and the surface tension; it is tentatively attributed to a phase separation in the liquid state. The VIT 101 specimen exhibited a small undercooling of about 50 K. Specific heat measurements were performed in the stable and undercooled melt. These various results will be combined with ground based work such as the measurement of T-T-T curves in the electrostatic levitator and low temperature viscosity and specific heat measurements for modeling the nucleation kinetics of these alloys.

  7. Simulating SiD Calorimetry: Software Calibration Procedures and Jet Energy Resolution

    International Nuclear Information System (INIS)

    Cassell, R.

    2009-01-01

    Simulated calorimeter performance in the SiD detector is examined. The software calibration procedures are described, as well as the perfect pattern recognition PFA reconstruction. Performance of the SiD calorimeters is summarized with jet energy resolutions from calorimetry only, perfect pattern recognition and the SiD PFA algorithm. Presented at LCWS08(1). Our objective is to simulate the calorimeter performance of the SiD detector, with and without a Particle Flow Algorithm (PFA). Full Geant4 simulations using SLIC(2) and the SiD simplified detector geometry (SiD02) are used. In this geometry, the calorimeters are represented as layered cylinders. The EM calorimeter is Si/W, with 20 layers of 2.5mm W and 10 layers of 5mm W, segmented in 3.5 x 3.5mm 2 cells. The HAD calorimeter is RPC/Fe, with 40 layers of 20mm Fe and a digital readout, segmented in 10 x 10mm 2 cells. The barrel detectors are layered in radius, while the endcap detectors are layered in z(along the beam axis)

  8. Misuse of thermodynamics in the interpretation of isothermal titration calorimetry data for ligand binding to proteins.

    Science.gov (United States)

    Pethica, Brian A

    2015-03-01

    Isothermal titration calorimetry (ITC) has given a mass of data on the binding of small molecules to proteins and other biopolymers, with particular interest in drug binding to proteins chosen as therapeutic indicators. Interpretation of the enthalpy data usually follows an unsound protocol that uses thermodynamic relations in circumstances where they do not apply. Errors of interpretation include incomplete definitions of ligand binding and equilibrium constants and neglect of the non-ideality of the solutions under study, leading to unreliable estimates of standard free energies and entropies of binding. The mass of reported thermodynamic functions for ligand binding to proteins estimated from ITC enthalpies alone is consequently of uncertain thermodynamic significance and utility. ITC and related experiments to test the protocol assumptions are indicated. A thermodynamic procedure avoiding equilibrium constants or other reaction models and not requiring protein activities is given. The discussion draws attention to the fundamental but neglected relation between the thermodynamic activity and bioactivity of drugs and to the generally unknown thermodynamic status of ligand solutions, which for drugs relates directly to effective therapeutic dosimetry. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. PREFACE: XVth International Conference on Calorimetry in High Energy Physics (CALOR2012)

    Science.gov (United States)

    Akchurin, Nural

    2012-12-01

    The XVth International Conference on Calorimetry in High Energy Physics, CALOR2012, was held in Santa Fe, New Mexico from 4-8 June 2012. The series of conferences on calorimetry started in 1990 at Fermilab, and they have been the premier event for calorimeter aficionados, a trend that CALOR2012 upheld. This year, several presentations focused on the status of the major calorimeter systems, especially at the LHC. Discussions on new and developing techniques in calorimetry took a full day. Excellent updates on uses of calorimeters or about ideas that are deeply rooted in particle physics calorimetry in astrophysics and neutrino physics were followed by talks on algorithms and special triggers that rely on calorimeters. Finally, discussions of promising current developments and ongoing R&D work for future calorimeters capped the conference. The field of calorimetry is alive and well, as evidenced by the more than 100 attendees and the excellent quality of over 80 presentations. You will find the written contributions in this volume. The presentations can be found at calor2012.ttu.edu. The first day of the conference was dedicated to the LHC. In two invited talks, Guillaume Unal (CERN) and Tommaso Tabarelli de Fatis (Universita' & INFN Milano Bicocca) discussed the critical role electromagnetic calorimeters play in the hunt for the Standard Model Higgs boson in ATLAS and CMS, respectively. The enhanced sensitivity for light Higgs in the two-gamma decay channel renders electromagnetic calorimeters indispensible. Much of the higher mass region was already excluded for the SM Higgs by the time of this conference, and after less than a month, on 4 July, CERN announced the discovery of a new boson at 125 GeV, a particle that seems consistent with the Higgs particle so far. Once again, without the electromagnetic calorimeters, this would not have been possible. Professor Geoffrey West from the Santa Fe Institute gave the keynote address. His talk, 'Universal Scaling Laws

  10. Indirect Climatic Effects of Major Volcanic Eruptions

    Science.gov (United States)

    Hofmann, D. J.

    2007-05-01

    The direct effects on climate, related to atmospheric emissions to the atmosphere following major volcanic eruptions, are well-known although the sparseness of such eruptions make detailed study on the range of such variations difficult. In general terms, infrared absorption by volcanic emissions to the stratosphere result in local heating early in the event when gaseous sulfur compounds exist. This early period is followed by gas to particle conversion, on a time scale of 1-2 months, promoting the formation of sulfuric acid-water droplets. Coagulation and droplet growth result in the "volcanic stratospheric aerosol layer" which is related to the predominant direct climatic effect of large eruptions, the cooling of the troposphere by backscattering of solar visible radiation to space with a recovery time scale of 1-2 years. In this paper we will discuss some of the less-known "indirect" effects of the volcanic stratospheric aerosol on climate. We label them indirect as they act on climate through intermediary atmospheric constituents. The intermediaries in the volcanic indirect climatic effect are generally atmospheric greenhouse gases or other atmospheric gases and conditions which affect greenhouse gases. For example, cooling of the troposphere following major eruptions reduces the growth rate of atmospheric carbon dioxide related to respiration by the terrestrial biosphere. In addition, redirection of part of the direct solar beam into diffuse radiation by the volcanic stratospheric aerosol stimulates plant photosynthesis, further reducing the carbon dioxide growth rate. The growth rate of the second-most important atmospheric greenhouse gas, methane, is also affected by volcanic emissions. Volcanic stratospheric aerosol particles provide surface area which catalyzes heterogeneous chemical reactions thus stimulating removal of stratospheric ozone, also a greenhouse gas. Although major droughts usually related to ENSO events have opposite effects on carbon

  11. Vaginal carcinoma in a young woman who underwent fertility-sparing treatment involving chemotherapy and conservative surgery.

    Science.gov (United States)

    Mabuchi, Yasushi; Yahata, Tamaki; Kobayashi, Aya; Tanizaki, Yuko; Minami, Sawako; Ino, Kazuhiko

    2015-06-01

    Vaginal carcinoma is a rare gynecological malignancy that is usually treated by radiation therapy and/or surgery combined with chemotherapy. Here, we report a case of invasive vaginal carcinoma in a young woman who underwent fertility-sparing treatment involving neoadjuvant chemotherapy and conservative surgery. A 36-year-old non-parous woman had a solid tumor in the vagina. Positron emission tomography/computed tomography showed a tumor in the vagina with high FDG uptake (SUV = 17.33) but no metastatic lesions. The patient was diagnosed with vaginal squamous cell carcinoma, FIGO stage I, T1N0M0. Because she wished to retain her fertility, neoadjuvant chemotherapy consisting of irinotecan hydrochloride and nedaplatin was initiated. After four courses of chemotherapy, partial vaginectomy was carried out and the pathological diagnosis of the residual lesion was VAIN 3. Following two further courses of the same chemotherapy, she obtained complete response, and has shown no evidence of disease for 14 months. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  12. Prosthetic reconstruction with an obturator using swing-lock attachment for a patient underwent maxillectomy: A clinical report

    Science.gov (United States)

    2016-01-01

    Patients who underwent resection of maxilla due to benign or malignant tumor, or accident will have defect in palatal area. They get retention, support and stability from remaining tissues which are hardly optimal. The advantage of swing-lock attachment design is having multiple contacts on labial and lingual side of the abutment teeth by retentive strut and palatal bracing component. Because the force is distributed equally to abutment teeth, abutment teeth of poor prognosis can be benefited from it. It is also more advantageous to cover soft tissue defects which are hard to reach with conventional prosthesis. A 56-year-old female patient who had undergone a maxillectomy due to malignant melanoma complaining of loose and unstable surgical obturator. Surveyed crowns were placed on #12, 26, and 27. Teeth #11, 21, 22, and 23 had lingual rest seat and #24 had mesial rest seat to improve stability and support of the obturator. This clinical report presents the prosthetic management of a patient treated with obturator on the maxilla using swing-lock attachment to the remaining teeth. PMID:27826392

  13. Anatomical location of metastatic lymph nodes: an indispensable prognostic factor for gastric cancer patients who underwent curative resection.

    Science.gov (United States)

    Zhao, Bochao; Zhang, Jingting; Zhang, Jiale; Chen, Xiuxiu; Chen, Junqing; Wang, Zhenning; Xu, Huimian; Huang, Baojun

    2018-02-01

    Although the numeric-based lymph node (LN) staging was widely used in the worldwide, it did not represent the anatomical location of metastatic lymph nodes (MLNs) and not reflect extent of LN dissection. Therefore, in the present study, we investigated whether the anatomical location of MLNs was still necessary to evaluate the prognosis of node-positive gastric cancer (GC) patients. We reviewed 1451 GC patients who underwent radical gastrectomy in our institution between January 1986 and January 2008. All patients were reclassified into several groups according to the anatomical location of MLNs and the number of MLNs. The prognostic differences between different patient groups were compared and clinicopathologic features were analyzed. In the present study, both anatomical location of MLNs and the number of MLNs were identified as the independent prognostic factors (p location of MLNs was considered (p location of MLNs had no significant effect on the prognosis of these patients, the higher number of MLNs in the extraperigastric area was correlated with the unfavorable prognosis (p location of MLNs was an important factor influencing the prognostic outcome of GC patients. To provide more accurate prognostic information for GC patients, the anatomical location of MLNs should not be ignored.

  14. Transcranial doppler sonography in two patients who underwent decompressive craniectomy for traumatic brain swelling: report of two cases

    Directory of Open Access Journals (Sweden)

    Bor-Seng-Shu Edson

    2004-01-01

    Full Text Available The role of decompressive craniectomy in the treatment of severe posttraumatic cerebral swelling remains quite a controversial issue. To the best of our knowledge, there is no study demonstrating the effect of decompressive craniectomy on cerebral blood flow (CBF velocity by means of transcranial Doppler sonography (TCD. We present two patients who developed traumatic brain swelling and uncontrollable intracranial hypertension with coma and signs of transtentorial herniation. One patient underwent bifrontal, while the second, unilateral, frontotemporoparietal decompressive craniectomy with dural expansion. In both patients, TCD examinations were performed immediately before and after surgery to study the cerebral hemodynamic changes related to the operations. Pre and postoperative TCD examinations demonstrated a significant increase in blood flow velocity in the intracranial arteries in both subjects. In conclusion, our cases suggest that decompressive craniectomy with dural expansion may result in elevation of CBF velocity in patients with massive brain swelling. The increase in CBF velocity appears to occur not only in the decompressed hemisphere, but also on the opposite side.

  15. Assessment of quality of life of patients who underwent anterior cruciate ligament reconstruction and a rehabilitation program

    Directory of Open Access Journals (Sweden)

    Moises Cohen

    2004-12-01

    Full Text Available Introduction: Quality of life can be defined as the expression of aconceptual model that tries to represent patient’s perspectivesand his/her level of satisfaction expressed by numbers. Theobjective of this study is to evaluate the parameters of quality oflife of 23 patients who underwent surgery for anterior cruciateligament reconstruction. Methods: We adopted SF-36, a generichealth-related evaluation questionnaire, to obtain informationregarding several aspects of patients’ health conditions, and theLysholm questionnaire, specific to evaluate the symptoms andfunction of the knee. The questionnaires were applied at two stagesof the treatment: pre- and postoperatively (after the rehabilitationprogram. Results: Before surgery, the Lysholm questionnairepresented the following results: excellent in 4% of the cases, goodin 22%, fair in 22%, and poor in 52%. After surgery (Lysholm e SF-36 the correlation level was approximately 44% (p = 0.041.Discussion: The correlation between the Lysholm and the SF-36questionnaires showed the following: the lower the level of pain,the higher the Lysholm score. The high scores presented by theLysholm questionnaire are directly proportional to physical andemotional aspects, and to functional capacity. Conclusion:Analysis of both questionnaires, as well as of their correlation,showed some improvement in patients´ quality of life. We werealso able to demonstrate the importance and usefulness of applyingthe two questionnaires at three different moments: before, duringand after physiotherapeutic intervention.

  16. The Characteristics of Cervical Cancer Patients Who Underwent a Radical Hysterectomy at Sanglah Hospital Denpasar in 2015

    Directory of Open Access Journals (Sweden)

    I Nyoman Bayu Mahendra

    2016-05-01

    Full Text Available Background: Cervical cancer is the most common gynecologic cancer in women. It is the main cause of cancer-related death in women in developing countries. Cervical cancer in Indonesia is the second most cancer affecting Indonesian women and the prevalence is relatively stable in the last 30 years. Cervical cancer was closely related to the histologic type of itself. A squamous cell carcinoma has a specific route of local spreading and a lymphatic route. The sample of this study are cervical cancer patients who underwent a radical hysterectomy from January 1 to December 31, 2015 in Sanglah Hospital Denpasar, Bali. The aim of this study is to discover the characteristics of the patients by age, parity, education level, marital status, sexual activity, the first symptoms and the early screening done, and the clinical staging. Methods: This descriptive study involved 20 patients in Sanglah Hospital Denpasar who had a radical hysterectomy from January 1 until December 31, 2015. The characteristics are gathered from the patients’ medical record. Results: The most cases done radical hysterectomy between 41-45 years old which proportion was 40%, the most parity was parity 2 (60%, elementary school was the most education level (35%, all of the samples only married once and sexually active, the most first symptom was vaginal bleeding (55%, only 10% had pap smear as early detection, and the most clinical stage was stage IIB (50%.

  17. A systematic review of methods for quantifying serum testosterone in patients with prostate cancer who underwent castration.

    Science.gov (United States)

    Comas, I; Ferrer, R; Planas, J; Celma, A; Regis, L; Morote, J

    2018-03-01

    The clinical practice guidelines recommend measuring serum testosterone in patients with prostate cancer (PC) who undergo castration. The serum testosterone concentration should be IA) has become widespread, although their metrological characteristics do not seem appropriate for quantifying low testosterone concentrations. The objective of this review is to analyse the methods for quantifying testosterone and to establish whether there is scientific evidence that justifies measuring it in patients with PC who undergo castration, through liquid chromatography attached to a mass spectrometry in tandem (LC-MSMS). We performed a search in PubMed with the following MeSH terms: measurement, testosterone, androgen suppression and prostate cancer. We selected 12 studies that compared the metrological characteristics of various methods for quantifying serum testosterone compared with MS detection methods. IAs are standard tools for measuring testosterone levels; however, there is evidence that IAs lack accuracy and precision for quantifying low concentrations. Most chemiluminescent IAs overestimate their concentration, especially below 100ng/dL. The procedures that use LC-MSMS have an adequate lower quantification limit and proper accuracy and precision. We found no specific evidence in patients with PC who underwent castration. LC-MSMS is the appropriate method for quantifying low serum testosterone concentrations. We need to define the level of castration with this method and the optimal level related to better progression of the disease. Copyright © 2017 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Studies on the clinical course of chronic hepatitis in the patients who underwent serial needle liver biopsies

    International Nuclear Information System (INIS)

    Hirata, Tetsuro

    1984-01-01

    In order to evaluate the changes in biochemical liver function tests and hepatic scintigraphic findings of chronic hepatitis, the author analyzed 35 patients who underwent serial liver biopsies. The results were summerized as follows: 1. Histological deteriorations in chronic hepatitis more inclined to be presented in the scintigraphic abnormalities such as the increased uptake of radioisotope in the spleen and bone marrow than the deteriorations in biochemical liver function tests. Moreover, the increased radioisotope uptake by spleen and bone marrow in hepatic scintigram highly correlated with histological deteriorations. On the other hand, in the cases with histological improvement no scintigraphic improvement was ovserved. 2. Comparing the changes in the result of liver function tests with histological features, biochemical deteriorations significantly correlated with histological deteriorations, although biochemical improvements were not reliable indicators of histological improvements. 3. Changes in biochemical parameters such as serum GOT, GPT, albumin, γ-globulin, TTT and ALP were analyzed by means of Hayashi's second method of quantification and predictive values for histological feactures were calculated. As a result, histological deteriorations were predicted in 89.5% of the cases, but histological improvements were predicted only in 66.7%. In the various biochemical parameters, γ-globulin was considered as most important in predicting histological features and ALP was ranked the second. (J.P.N.)

  19. The Effect of Prazosin and Oxybutynin on the Symptoms Due to Using Double J Catheter in Patients Underwent TUL

    Directory of Open Access Journals (Sweden)

    K. Tavakkoli Tabassi

    2014-01-01

    Full Text Available Background & Aims: Double J catheter has been used for years as an independent practice or a part of other urological practices. Although these catheters have solved many patients’ problems but those can cause symptoms and problems for patients. The aim of this study was the investigation the effect of prazosin and oxybutynin on the degree of symptoms due to using Double J catheter. Methods: In this interventional study, patients who underwent TUL from July 2008 to march 2008 in the lithotripsy ward of Imam Reza hospital were entered to the study and randomly divided in 3 groups randomly. In the first group, placebo, in the second group, oxybutynin, in the third group prazosin were prescribed. Three weeks later standard questionnaire Ureteric Stent Symptom Questionnaire (USSQ was completed. After collecting data, was analyzed using SPSS software. Results: A total of 113 patients (70 men 43 women were included to the study. The mean age was 39 years. There were no significance difference among urinary symptoms score pain of body and physical activity problems in three groups (P>0.05, but there was a significant difference in general health and work problems among them (P<0.05. Conclusion: Oxybutynin caused a low effect on improvement of general health and work problems in patients who were studied. It might Prazosin does not has a sufficient time to affect on urinary symptoms, because of shortness of usage.

  20. Indirect effects in community ecology: Their definition, study and importance.

    Science.gov (United States)

    Strauss, S Y

    1991-07-01

    The diversity of indirect interactions that can occur within communities is large. Recent research on indirect interactions is scattered in the literature under numerous labels. The definition of indirect effects is an important aspect of their study, and clarifies some of the subtle differences among indirect effects found in natural communities. Choosing which species to study, how to manipulate species and for what duration, which attributes to measure and, finally, which analytical techniques to use are all problems facing the community ecologist. Ultimately, we are striving for the best means of determining the relative importance of direct and indirect effects in structuring communities. Copyright © 1991. Published by Elsevier Ltd.

  1. Percentages of NKT cells in the tissues of patients with non-small cell lung cancer who underwent surgical treatment.

    Science.gov (United States)

    Pyszniak, Maria; Rybojad, Paweł; Pogoda, Katarzyna; Jabłonka, Andrzej; Bojarska-Junak, Agnieszka; Tabarkiewicz, Jacek

    2014-03-01

    Natural killer T (NKT) cells are involved in the antitumor response by direct cytotoxicity and indirectly through activation of effector cells. Recent studies have shown a relationship between the number and function of NKT cells and clinical outcomes. NKT cells seem to represent a promising tool for immunotherapy of cancer. The aim of the study was to evaluate the distribution of NKT cells in peripheral blood, lymph nodes and tumor tissue of non-small cell lung cancer (NSCLC) patients, as well as development of the most efficient set of cytokines stimulating differentiation of NKT cells. We evaluated the percentage of iNKT+CD3+ cells in the tissues collected from patients with NSCLC. For the generation of NKT cells, we cultured cells isolated from the blood of 20 healthy donors and from the tissues of 4 NSCLC patients. Cells were stimulated with α-GalCer in combinations with cytokines. We noted significant differences in the percentages of NKT cells in the patients' tissues. The highest percentage of these cells was observed in the tumor tissue and the lowest in the lymph nodes. In vitro, in healthy donors all α-GalCer-cytokine combinations were effective in stimulation of NKT cells' proliferation. NKT cells' proliferation was the most efficiently stimulated by α-GalCer+IL-2+IL-7 and α-GalCer+IL-2+IFN-γ. Our results suggest that in the course of NSCLC, NKT cells migrate to the primary tumor and accumulate therein. All tested combinations of α-GalCer and cytokines were capable of generation of NKT cells in vitro.

  2. Indirect evaporative coolers with enhanced heat transfer

    Science.gov (United States)

    Kozubal, Eric; Woods, Jason; Judkoff, Ron

    2015-09-22

    A separator plate assembly for use in an indirect evaporative cooler (IEC) with an air-to-air heat exchanger. The assembly includes a separator plate with a first surface defining a dry channel and a second surface defining a wet channel. The assembly includes heat transfer enhancements provided on the first surface for increasing heat transfer rates. The heat transfer enhancements may include slit fins with bodies extending outward from the first surface of separator plate or may take other forms including vortex generators, offset strip fins, and wavy fins. In slit fin implementations, the separator plate has holes proximate to each of the slit fins, and the separator plate assembly may include a sealing layer applied to the second surface of the separator plate to block air flow through the holes. The sealing layer can be a thickness of adhesive, and a layer of wicking material is applied to the adhesive.

  3. Haloperidol Selectively Remodels Striatal Indirect Pathway Circuits

    Science.gov (United States)

    Sebel, Luke E; Graves, Steven M; Chan, C Savio; Surmeier, D James

    2017-01-01

    Typical antipsychotic drugs are widely thought to alleviate the positive symptoms of schizophrenia by antagonizing dopamine D2 receptors expressed by striatal spiny projection neurons (SPNs). What is less clear is why antipsychotics have a therapeutic latency of weeks. Using a combination of physiological and anatomical approaches in ex vivo brain slices from transgenic mice, it was found that 2 weeks of haloperidol treatment induced both intrinsic and synaptic adaptations specifically within indirect pathway SPNs (iSPNs). Perphenazine treatment had similar effects. Some of these adaptations were homeostatic, including a drop in intrinsic excitability and pruning of excitatory corticostriatal glutamatergic synapses. However, haloperidol treatment also led to strengthening of a subset of excitatory corticostriatal synapses. This slow remodeling of corticostriatal iSPN circuitry is likely to play a role in mediating the delayed therapeutic action of neuroleptics. PMID:27577602

  4. Indirect Encoding in Neuroevolutionary Ship Handling

    Directory of Open Access Journals (Sweden)

    Miroslaw Lacki

    2018-03-01

    Full Text Available In this paper the author compares the efficiency of two encoding schemes for artificial intelligence methods used in the neuroevolutionary ship maneuvering system. This may be also be seen as the ship handling system that simulates a learning process of a group of artificial helmsmen - autonomous control units, created with an artificial neural network. The helmsman observes input signals derived form an enfironment and calculates the values of required parameters of the vessel maneuvering in confined waters. In neuroevolution such units are treated as individuals in population of artificial neural networks, which through environmental sensing and evolutionary algorithms learn to perform given task efficiently. The main task of this project is to evolve a population of helmsmen with indirect encoding and compare results of simulation with direct encoding method.

  5. Indirect adaptive control of discrete chaotic systems

    International Nuclear Information System (INIS)

    Salarieh, Hassan; Shahrokhi, Mohammad

    2007-01-01

    In this paper an indirect adaptive control algorithm is proposed to stabilize the fixed points of discrete chaotic systems. It is assumed that the functionality of the chaotic dynamics is known but the system parameters are unknown. This assumption is usually applicable to many chaotic systems, such as the Henon map, logistic and many other nonlinear maps. Using the recursive-least squares technique, the system parameters are identified and based on the feedback linearization method an adaptive controller is designed for stabilizing the fixed points, or unstable periodic orbits of the chaotic maps. The stability of the proposed scheme has been shown and the effectiveness of the control algorithm has been demonstrated through computer simulations

  6. Periodical assessment of genitourinary and gastrointestinal toxicity in patients who underwent prostate low-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Tanaka, Nobumichi; Asakawa, Isao; Anai, Satoshi; Hirayama, Akihide; Hasegawa, Masatoshi; Konishi, Noboru; Fujimoto, Kiyohide

    2013-01-01

    To compare the periodical incidence rates of genitourinary (GU) and gastrointestinal (GI) toxicity in patients who underwent prostate low-dose-rate brachytherapy between the monotherapy group (seed implantation alone) and the boost group (in combination with external beam radiation therapy (EBRT)). A total of 218 patients with a median follow-up of 42.5 months were enrolled. The patients were divided into 2 groups by treatment modality, namely, the monotherapy group (155 patients) and the boost group (63 patients). The periodical incidence rates of GU and GI toxicity were separately evaluated and compared between the monotherapy group and the boost group using the National Cancer Institute - Common Terminology Criteria for Adverse Events, version 3.0. To elucidate an independent factor among clinical and postdosimetric parameters to predict grade 2 or higher GU and GI toxicity in the acute and late phases, univariate and multivariate logistic regression analyses were carried out. Of all patients, 78.0% showed acute GU toxicity, and 7.8% showed acute GI toxicity, while 63.8% showed late GU toxicity, and 21.1% showed late GI toxicity. The incidence rates of late GU and GI toxicity were significantly higher in the boost group. Multivariate analysis showed that the International Prostate Symptom Score (IPSS) before seed implantation was a significant parameter to predict acute GU toxicity, while there were no significant predictive parameters for acute GI toxicity. On the other hand, combination with EBRT was a significant predictive parameter for late GU toxicity, and rectal volume (mL) receiving 100% of the prescribed dose (R100) was a significant predictive parameter for late GI toxicity. The boost group showed higher incidence rates of both GU and GI toxicity. Higher IPSS before seed implantation, combination with EBRT and a higher R100 were significant predictors for acute GU, late GU and late GI toxicity

  7. Clinical and echocardiographic findings of patients with suspected acute pulmonary thromboembolism who underwent computed tomography pulmonary angiography

    Directory of Open Access Journals (Sweden)

    Atoosa Adibi

    2016-01-01

    Full Text Available Background: The aim of the study was to determine the correlation between clinical and echocardiographic findings and risk factors of patients with suspected acute pulmonary thromboembolism (PTE who underwent computed tomography pulmonary angiography (CTPA. Materials and Methods: In this cross-sectional study, 310 hospitalized patients aged >18 years with high clinical suspicion of PTE referred to imaging center of our hospital from different wards for CTPA were enrolled. The frequency of different clinical presentations, risk factors, items of Wells' criteria, and echocardiographic findings was compared in patients with and without PTE, which have been diagnosed according to the CTPA results. Results: PTE was diagnosed in 53 (17.1% of patients with suspected PTE. From clinical manifestations, tachypnea, pleuritic chest pain, and edema of lower extremities were significantly more frequent among patients with PTE (P < 0.05. Major surgery was the risk factor which was significantly more prevalent among patients with PTE (P < 0.05. Frequency of all criteria of Wells' criteria, except hemoptysis, was significantly higher in patients with PTE (P < 0.05. The frequency of all studied echocardiographic variables was significantly higher in patients with PTE (P < 0.05. Conclusion: It is suggested that we could use the results of this study for utilizing the diagnostic process of PTE in patients with highly clinical suspicion of PTE and providing more validated decision. Using the results of this study, we could identify high-risk patients and made appropriate risk assessment for better management of patients with suspected PTE as well as reduce the rate of unnecessary CTPA and its related adverse consequences.

  8. The effects of transfusion of irradiated blood upon cellular immune response in patients underwent open heart surgery

    International Nuclear Information System (INIS)

    Togashi, Ken-ichi; Nakazawa, Satoshi; Moro, Hisanaga; Yazawa, Masatomo; Kanazawa, Hiroshi; Hayashi, Jun-ichi; Yamazaki, Yoshihiko; Eguchi, Shoji

    1989-01-01

    The purpose of this paper is to demonstrate the effect of the transfusion of blood received 1500 rad exposure upon the immune response in 14 patients underwent various type of cardiac surgery. 13 patients received known amounts banked blood and irradiated fresh blood, while one patient received a lot of amounts of banked and irradiated and non-irradiated fresh blood. The authors studied the numbers of lymphocytes as well as lymphocyte subsets such as pan-T cells, B cells, helper/inducer T cells (T H/I ), cytotoxic/supressor T cells (T C/S ), active T cells, natural killer (NK) cells and NK cell activity during two weeks after surgeries. In all 14 patients, pan-T lymphocytes decreased markedly in a few days after surgeries, but increased to higher levels on the eight postoperative day than the levels preoperatively. T H/I and T C/S lymphocytes changed on the similar pattern as pan-T lymphocytes. Active T and B cells did not change significantly in two weeks. The number and activity of NK cells gave the lowest levels on the second postoperative day and did not recovery to the preoperative levels in two weeks. One patient received non-irradiated fresh blood showed the similar immune response as other 13 patients, while he gave the lower levels than others did. This patient died of graft-versus-host disease (GVHD)-like syndrome on the 36th postoperative day. It may be thought that the transfusion of irradiated blood would prevent the host from GVHD and gave the better effects on the immune response than that of non-irradiated blood following open-heart surgeries. (author)

  9. Early prediction of treatment response by serum CRP levels in patients with advanced esophageal cancer who underwent definitive chemoradiotherapy

    International Nuclear Information System (INIS)

    Yoneda, Masayuki; Fujiwara, Hitoshi; Okamura, Shinichi

    2010-01-01

    Serum C reactive protein (CRP) has been shown to be associated with the progression of esophageal cancer. The purpose of this study was to examine the relationship between treatment response and serum CRP levels in time course during definitive chemoradiotherapy (CRT) in terms of early prediction of CRT response by serum CRP. The subjects of this study were 36 patients with cT3/cT4 esophageal squamous cell carcinoma who underwent definitive CRT in our hospital. Serum CRP levels during definitive CRT (pretreatment, 1W, 2W and 3W after CRT initiation) were compared between CR and non-CR group. In addition, partition model was constructed to discriminate CR with non-CR and the prediction accuracy was evaluated. The patients were consisted of 28 males and 8 females. At pretreatment diagnosis, tumors were categorized as T3 (n=21) and T4 (n=15). Thirty four patients received FP-based chemotherapy and 2 patients received docetaxel-based chemotherapy. Treatment responses were categorized as CR (n=8), partial response (PR) (n=14), no change (NC) (n=2) and progressive disease (PD) (n=12). Serum CRP levels at the time of 2W after CRT initiation (CRT2W) in CR group were low compared to those in non-CR group (p=0.071). The partition model was constructed based on CRP levels at CRT2W. The prediction accuracies to discriminate CR from non-CR by CRP ≤0.1 were 50%, 82%, and 75% in sensitivity, specificity and accuracy, respectively. Serum CRP is a useful biomarker for an early prediction of CRT response. (author)

  10. CA-125–indicated asymptomatic relapse confers survival benefit to ovarian cancer patients who underwent secondary cytoreduction surgery

    Directory of Open Access Journals (Sweden)

    Wang Fang

    2013-02-01

    Full Text Available Abstract Background There is no consensus regarding the management of ovarian cancer patients, who have shown complete clinical response (CCR to primary therapy and have rising cancer antigen CA-125 levels but have no symptoms of recurrent disease. The present study aims to determine whether follow-up CA-125 levels can be used to identify the need for imaging studies and secondary cytoreductive surgery (CRS. Methods We identified 410 ovarian cancer patients treated at The University of Texas MD Anderson Cancer Center between 1984 and 2011. These patients had shown CCR to primary therapy. Follow-up was conducted based on the surveillance protocol of the MD Anderson Cancer Center. We used the Cox proportional hazards model and log-rank test to assess the associations between the follow-up CA-125 levels and secondary CRS and survival duration. Results The CA-125 level of 1.68 × nadir was defined as the indicator of recurrent disease (p  1.68 × nadir at relapse (55.7 and 10.4 months; p = 0.04 and 0.01, respectively. The overall and progression free survival duration of patients with asymptomatic relapse and underwent a secondary CRS was longer than that of patients with symptomatic relapse (p = 0.02 and 0.04 respectively. Conclusions The increase of serum CA-125 levels is an early warning of clinical relapse in ovarian cancer. Using CA-125 levels in guiding the treatment of patients with asymptomatic recurrent ovarian cancer, who have shown CCR to primary therapy, can facilitate optimal secondary CRS and extend the survival duration of the patients.

  11. Comparison of quality of life between men and women who underwent Transforaminal Percutaneous Endoscopic Discectomy for lumbar disc herniation.

    Science.gov (United States)

    Kapetanakis, Stylianos; Gkasdaris, Grigorios; Thomaidis, Tryfon; Charitoudis, Georgios; Kazakos, Konstantinos

    2017-01-01

    Studies describing the efficacy of TPED on shortness of recovery and improvement of postoperative quality of life are limited, especially regarding gender something that has never been reported before in the literature. The purpose of this study is to evaluate possible differences of the health-related quality of life in patients who underwent TPED for LDH in accordance with sex. Seventy-six patients diagnosed and treated with TPED for LDH with 1 year follow-up were selected and divided into two groups of equal number depending on sex. Their quality of life was evaluated by using the SF-36 before the operation, six weeks, three, six and twelve months postoperatively. A statistical analysis was conducted, in order to compare the 8 scaled scores of the SF-36 combining each time two chronological phases in the total of patients, in each group and between groups. Fifty-two (68.4%) patients were ≤63 years old, while the rest 24 (31,4%) were >63 years old (mean ±SD = 56,5 ±12,1 years). Apart from the PF domain, the scores were higher in every visit for the two groups, but the change between groups was not significant. Women had a significantly higher increase of PF score in 3 months after TPED and in the interval 6 weeks-3 months comparing with men. However, in the intervals 3 months-6 months and 3 months-12 months men presented significantly higher increase compared to women. Statistically significant improvement of the quality of life for both men and women was observed. Generally, there was no significant difference between the two groups. As regards to the physical functioning, it appears to be a significant difference which is counterpoised over time. 2. TPED for LDH does not present major differences in the improvement of quality of life regarding gender.

  12. Preoperative evaluation of myocardial viability by thallium-201 imaging in patients with old myocardial infarction who underwent coronary revascularization

    International Nuclear Information System (INIS)

    Naruse, Hitoshi; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Miyamoto, Takashi; Fukuchi, Minoru

    1992-01-01

    The myocardial uptake and redistribution in thallium scintigraphy and the regional wall motion by echocardiography were evaluated by a semi-quantitative method in 42 patients who previously had myocardial infarction (50 target vessels) and underwent coronary revascularization. The aim of this study was to elucidate the significance of the initial image, delayed image and redistribution on thallium-201 scintigraphy for clinical diagnosis of the myocardial viability. As a semi-quantitative analysis, we used a bull's-eye display for thallium image and centerline method for echocardiographic wall motion, and compared the results before and after revascularization. As a result, the thallium grade improved postoperatively in all 17 areas which preoperatively had showed redistribution, and also in 11 of the 32 areas without preoperative redistribution. The sensitivity, specificity and accuracy of preoperative thallium redistribution for predicting myocardial viability were 61%, 100% and 78%, respectively, when the postoperative improvement in the thallium grade was used as the standard. The postoperative probability of improvement in the thallium grade increased in proportion to the preoperative grade (delayed image)(p<0.01). There was no correlation between the preoperative thallium delayed image and postoperative improvement in wall motion. Postoperative improvement in thallium image and wall motion could not be predicted from the preoperative wall motion. Thus, postoperative improvement in thallium images can be anticipated if redistribution is present on the preoperative thallium image, and the preoperative thallium delayed image is useful for predicting myocardial viability. Improvement in wall motion could not be predicted preoperatively by these methods. (author)

  13. The diagnostic value of indirect lower limb CT venography in the lower extremity deep venous thrombosis

    International Nuclear Information System (INIS)

    Zhu Li; Guo Youmin; Wang Jianguo; Guo Xiaojuan; Liu Min; Guo Yulin

    2009-01-01

    Objective: To evaluate indirect CT venography (CTV) in the diagnosis of deep venous thrombosis (DVT). Methods: A total of 516 acute pulmonary embolism patients proved by objective test were analyzed retrospectively. Using the results of lower limb compression sonography as reference standard, the sensitivity, specificity, positive predictive value and negative predictive value of indirect CTV were calculated. The agreement between lower extremity venous sonography and indirect CTV were assessed by Kappa analysis. Results: Among 516 patients with acute pulmonary thromboembolism (PTE), 110 patients underwent both CTV and CTPA and lower extremity sonography. DVT were detected by CTV and sonography simultaneously in 48 patients, while no DVT was detected in 39 patients by both examinations. Thirteen patients were diagnosed to have DVT by CTV without sonography detection, and DVT was detected in other 10 patients only by sonography. The sensitivity, specificity, positive predictive value and negative predictive value of indirect CTV was 82.8% (48/58), 75.0% (39/52), 78.7% (48/61) and 79.6% (39/49). The agreement between lower extremity venous sonography and indirect CTV was good for femoropopliteal vein (Kappa value range from 0.874 to 0.914, P=0.000). Thrombi detected by CTV were 62 and 52 respectively, and for sonography were 67 and 51 respectively. For calf veins, the agreement decreased (Kappa value range from 0.464 to 0.584, P=0.000). Thrombi detected by CTV were 6, 25 and 13 respectively, and for sonography were 13, 38 and 19 respectively. The agreement for external iliac vein was poor (Kappa value range from 0.230 to 0.262, P=0.067 and 0.004, respectively). Thrombi detected by CTV were 33, and for sonography were 17. Conclusions: The indirect CTV has high accuracy in the diagnosis of DVT. Combined CTPA and CTV can image pulmonary arteries and lower extremity veins in one examination. Indirect CTV can reveal thrombus in large pelvic veins, which has an advantage

  14. Kinetic calorimetry in the study of the mechanism of low-temperature chemical reactions

    Science.gov (United States)

    Barkalov, I. M.; Kiryukhin, D. P.

    Chemical reactions are always followed by a change in the reacting system enthalpy, hence, calorimetry as a method of enthalpy and heat capacity measuring is a universal and, sometimes, even the only possible way of studying chemical reaction kinetics. Throughout its long history, the calorimeter, having preserved the positions of the main method of thermodynamic studies, has conquered a new field of application: that of kinetic study of chemical reactions. The advantages and disadvantages of the kinetic calorimeter are now obvious. First, the advantages are: (1) the possibility of measuring the rate of a chemical reaction without any special requirements being imposed on the reaction medium (solid, viscous, multicomponent systems); (2) the high efficiency: a large volume of kinetic information in one experiment and a non-destructive character of changes; (3) the possibility of measuring directly in the field of ionizing radiation (γ-radiation, accelerated electrons) and light; and (4) recording of the chemical conversion directly at the time of its occurrence. The disadvantages of this method are: (1) the high inertia of standard calorimeter systems (τC⋍102-103S), which restricts the possibilities of studying fast processes; and (2) the complexity of the correct organization of the calorimeter experiment when the parameters of the process are changed (overheating in the sample, conversion of the process to explosive and auto wave regimens). One of the oldest and most universal methods of studying the mechanism of chemical reactions, calorimetry, is now passing through a period of turbulent development due to the advances in electronics and computerization. The wide variety of types of calorimeter set-ups and the large assortment of measurement schemes in the currently described methods complicate the experimental selection of the necessary instrument rather than facilitate it. The basic principles of the method, the types of calorimeters, and the measuring

  15. Kinetics of solid-gas reactions characterized by scanning AC nano-calorimetry with application to Zr oxidation

    International Nuclear Information System (INIS)

    Xiao, Kechao; Lee, Dongwoo; Vlassak, Joost J.

    2014-01-01

    Scanning AC nano-calorimetry is a recently developed experimental technique capable of measuring the heat capacity of thin-film samples of a material over a wide range of temperatures and heating rates. Here, we describe how this technique can be used to study solid-gas phase reactions by measuring the change in heat capacity of a sample during reaction. We apply this approach to evaluate the oxidation kinetics of thin-film samples of zirconium in air. The results confirm parabolic oxidation kinetics with an activation energy of 0.59 ± 0.03 eV. The nano-calorimetry measurements were performed using a device that contains an array of micromachined nano-calorimeter sensors in an architecture designed for combinatorial studies. We demonstrate that the oxidation kinetics can be quantified using a single sample, thus enabling high-throughput mapping of the composition-dependence of the reaction rate.

  16. Extensive studies on CeF{sub 3} crystals, a good candidate for electromagnetic calorimetry at future accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Auffray, E.; Baccaro, S.; Beckers, T.; Benhammou, Y.; Belsky, A.N.; Borgia, B.; Boutet, D.; Chipaux, R.; Dafinei, I.; De Notaristefani, F.; Depasse, P.; Dujardin, C.; El Mamouni, H.; Faure, J.L.; Fay, J.; Goyot, M.; Gupta, S.K.; Gurtu, A.; Hillemanns, H.; Ille, B.; Kirn, T.; Lebeau, M.; Lebrun, P.; Lecoq, P.; Mares, J.A.; Martin, J.P.; Mikhailin, V.V.; Moine, B.; Nelissen, J.; Nikl, M.; Pedrini, C.; Raghavan, R.; Sahuc, P.; Schmitz, D.; Schneegans, M.; Schwenke, J.; Tavernier, S.; Topa, V.; Vasil`ev, A.N.; Vivargent, M.; Walder, J.P. [CERN, Geneva (Switzerland)]|[ENEA Casaccia, INFN Rome, Rome (Italy)]|[VUB, Vrije Universiteit Brussels, Brussels (Belgium)]|[IPN of Lyon, IN2P3-CNRS and Universite Claude Bernard, Villeurbanne (France)]|[Synchrotron Radiation Laboratory, Moscow State University, Moscow (Russian Federation)]|[INFN Rome, Rome (Italy)]|[LPCML of Lyon, CNRS and Universite Claude Bernard, Villeurbanne (France)]|[CEA DSM/DAPNIA, CE-Saclay (France)]|[Tara Institute of Fundamental Research, Bombay (India)]|[Physics Institute, RWTH Aachen, Aachen (Germany)]|[LAPP, IN2P3-CNRS, Annecy-le-Vieux (France)]|[Institute of Physics, Academy of Sciences of Czech Republic, Prague (Czech Republic)]|[Institute of Atomic Physics (IFA), Bucharest (Romania)

    1996-12-11

    In the framework of its search for new heavy, fast and radiation hard scintillators for calorimetry at future colliders, the Crystal Clear Collaboration performed a systematic investigation of the properties and of the scintillation and radiation damage mechanisms of CeF{sub 3} monocrystals. Many samples of various dimensions up to 3 x 3 x 28 cm{sup 3} were produced by industry and characterised in the laboratories by different methods such as: optical transmission, light yield and decay time measurements, excitation and emission spectra, gamma and neutron irradiations. The results of these measurements are discussed. The measured light yield is compared to the theoretical expectations. Tests in high energy electron beams on a crystal matrix were also performed. The suitability of CeF{sub 3} for calorimetry at high rate machines is confirmed. Production and economical considerations are discussed. (orig.).

  17. Extensive studies on CeF3 crystals, a good candidate for electromagnetic calorimetry at future accelerators

    International Nuclear Information System (INIS)

    Auffray, E.; Baccaro, S.; Beckers, T.; Benhammou, Y.; Belsky, A.N.; Borgia, B.; Boutet, D.; Chipaux, R.; Dafinei, I.; De Notaristefani, F.; Depasse, P.; Dujardin, C.; El Mamouni, H.; Faure, J.L.; Fay, J.; Goyot, M.; Gupta, S.K.; Gurtu, A.; Hillemanns, H.; Ille, B.; Kirn, T.; Lebeau, M.; Lebrun, P.; Lecoq, P.; Mares, J.A.; Martin, J.P.; Mikhailin, V.V.; Moine, B.; Nelissen, J.; Nikl, M.; Pedrini, C.; Raghavan, R.; Sahuc, P.; Schmitz, D.; Schneegans, M.; Schwenke, J.; Tavernier, S.; Topa, V.; Vasil'ev, A.N.; Vivargent, M.; Walder, J.P.

    1996-01-01

    In the framework of its search for new heavy, fast and radiation hard scintillators for calorimetry at future colliders, the Crystal Clear Collaboration performed a systematic investigation of the properties and of the scintillation and radiation damage mechanisms of CeF 3 monocrystals. Many samples of various dimensions up to 3 x 3 x 28 cm 3 were produced by industry and characterised in the laboratories by different methods such as: optical transmission, light yield and decay time measurements, excitation and emission spectra, gamma and neutron irradiations. The results of these measurements are discussed. The measured light yield is compared to the theoretical expectations. Tests in high energy electron beams on a crystal matrix were also performed. The suitability of CeF 3 for calorimetry at high rate machines is confirmed. Production and economical considerations are discussed. (orig.)

  18. Application of the modulated temperature differential scanning calorimetry technique for the determination of the specific heat of copper nanofluids

    International Nuclear Information System (INIS)

    De Robertis, E.; Cosme, E.H.H.; Neves, R.S.; Kuznetsov, A.Yu.; Campos, A.P.C.; Landi, S.M.; Achete, C.A.

    2012-01-01

    The purpose of this work is to investigate the applicability of the modulated temperature differential scanning calorimetry technique to measure specific heat of copper nanofluids by using the ASTM E2719 standard procedure, which is generally applied to thermally stable solids and liquids. The one-step method of preparation of copper nanofluid samples is described. The synthesized nanoparticles were separated from the base fluid and examined by X-ray diffraction and transmission electron microscopy in order to evaluate their structure, morphology and chemical nature. The presence of copper nanoparticles in the base fluid alters the characteristics of crystallization and melting processes and reduces the specific heat values of nanofluids in the whole studied temperature range. - Highlights: ► Copper nanofluids prepared by one-step method. ► Methodology of synthesis improved nanofluid stability. ► Specific heat determinations using modulated temperature differential scanning calorimetry. ► Good agreement between theoretical and experimental values.

  19. The FIR-Radio Correlation in Rapidly Star-Forming Galaxies: The Spectral Index Problem and Proton Calorimetry

    Science.gov (United States)

    Thompson, Todd A.; Lacki, Brian C.

    We review the physics of the FIR-radio correlation (FRC) of star-forming galaxies, focusing on "electron calorimetry" as an explanation. We emphasize the importance of the "spectral index problem"—that galaxies have flatter GHz synchrotron spectra than predicted in the strong-cooling calorimeter limit. We argue that these shallow spectra require significant bremsstrahlung and/or ionization losses for the primary and secondary CR electron/positron populations. This then implies that CR protons suffer strong pionic losses before escape in dense starburst galaxies ("proton calorimetry"), and that these systems should be gamma-ray bright, forming a FIR-gamma-ray correlation. Implications for the diffuse non-thermal cosmic gamma-ray and neutrino backgrounds are mentioned. Caveats and uncertainties, as well as other solutions to the "spectral index problem" such as rapid advection of CRs in starburst superwinds, are highlighted.

  20. Binding of Cu(II) ions to peptides studied by fluorescence spectroscopy and isothermal titration calorimetry

    Science.gov (United States)

    Makowska, Joanna; Żamojć, Krzysztof; Wyrzykowski, Dariusz; Uber, Dorota; Wierzbicka, Małgorzata; Wiczk, Wiesław; Chmurzyński, Lech

    2016-01-01

    Steady-state and time-resolved fluorescence quenching measurements supported by Isothermal Titration Calorimetry (ITC) were used to study the interactions of Cu2 + with four peptides. Two of them were taken from the N-terminal part of the FBP28 protein (formin binding protein) WW domain: Tyr-Lys-Thr-Ala-Asp-Gly-Lys-Thr-Tyr-NH2 (D9) and its mutant Tyr-Lys-Thr-Ala-Asn-Gly-Lys-Thr-Tyr-NH2 (D9_M) as well as two mutated peptides from the B3 domain of the immunoglobulin binding protein G derived from Streptococcus: Asp-Val-Ala-Thr-Tyr-Thr-NH2 (J1) and Glu-Val-Ala-Thr-Tyr-Thr-NH2 (J2). The measurements were carried out at 298.15 K in 20 mM 2-(N-morpholino)ethanesulfonic acid (MES) buffer solution with a pH of 6. The fluorescence of all peptides was quenched by Cu2 + ions. The stoichiometry, conditional stability constants and thermodynamic parameters for the interactions of the Cu2 + ions with D9 and D9_M were determined from the calorimetric data. The values of the conditional stability constants were additionally determined from fluorescence quenching measurements and compared with those obtained from calorimetric studies. There was a good correlation between data obtained from the two techniques. On the other hand, the studies revealed that J1 and J2 do not exhibit an affinity towards metal ions. The obtained results prove that fluorescence quenching experiments may be successfully used in order to determine stability constants of complexes with fluorescent ligands. Finally, based on the obtained results, the coordinating properties of the peptides towards the Cu2 + ions are discussed.

  1. Strategies for assessing proton linkage to bimolecular interactions by global analysis of isothermal titration calorimetry data

    International Nuclear Information System (INIS)

    Coussens, Nathan P.; Schuck, Peter; Zhao, Huaying

    2012-01-01

    Highlights: ► We demonstrate the usefulness of global analysis of ITC data for proton-linked binding study. ► Various experimental strategies are evaluated for their information content. ► Data at multiple temperatures might improve the precision of binding parameters. ► Methods for detailed error analysis of parameter uncertainties are discussed. ► By global modeling, an uncertainty in molecular concentrations can be accounted for. - Abstract: Isothermal titration calorimetry (ITC) is a traditional and powerful method for studying the linkage of ligand binding to proton uptake or release. The theoretical framework has been developed for more than two decades and numerous applications have appeared. In the current work, we explored strategic aspects of experimental design. To this end, we simulated families of ITC data sets that embed different strategies with regard to the number of experiments, range of experimental pH, buffer ionization enthalpy, and temperature. We then re-analyzed the families of data sets in the context of global analysis, employing a proton linkage binding model implemented in the global data analysis platform SEDPHAT, and examined the information content of all data sets by a detailed statistical error analysis of the parameter estimates. In particular, we studied the impact of different assumptions about the knowledge of the exact concentrations of the components, which in practice presents an experimental limitation for many systems. For example, the uncertainty in concentration may reflect imperfectly known extinction coefficients and stock concentrations or may account for different extents of partial inactivation when working with proteins at different pH values. Our results show that the global analysis can yield reliable estimates of the thermodynamic parameters for intrinsic binding and protonation, and that in the context of the global analysis the exact molecular component concentrations may not be required. Additionally

  2. Beam calorimetry at the large negative ion source test facility ELISE: Experimental setup and latest results

    International Nuclear Information System (INIS)

    Nocentini, Riccardo; Bonomo, Federica; Ricci, Marina; Pimazzoni, Antonio; Fantz, Ursel; Heinemann, Bernd; Riedl, Rudolf; Wünderlich, Dirk

    2016-01-01

    Highlights: • ELISE is the first step in the European roadmap for the development of the ITER NBI. • Several beam diagnostic tools have been installed, the latest results are presented. • A gaussian fit procedure has been implemented to characterize the large ion beam. • Average beamlet group inhomogeneity is maximum 13%, close to the ITER target of 10%. • Beam divergence measured by calorimeter agrees with the BES measurements within 30%. - Abstract: The test facility ELISE is the first step within the European roadmap for the development of the ITER NBI system. ELISE is equipped with a 1 × 0.9 m"2 radio frequency negative ion source (half the ITER source size) and an ITER-like 3-grid extraction system which can extract an H"− or D"− beam for 10 s every 3 min (limited by available power supplies) with a total acceleration voltage of up to 60 kV. In the beam line of ELISE several beam diagnostic tools have been installed with the aim to evaluate beam intensity, divergence and uniformity. A copper diagnostic calorimeter gives the possibility to measure the beam power density profile with high resolution. The measurements are performed by an IR micro-bolometer camera and 48 thermocouples embedded in the calorimeter. A gaussian fit procedure has been implemented in order to characterize the large negative ion beam produced by ELISE. The latest results obtained from the beam calorimetry at ELISE show that the average beamlet group inhomogeneity is maximum 13%. The measured beam divergence agrees with the one measured by beam emission spectroscopy within 30%.

  3. Binding of Cu(II) ions to peptides studied by fluorescence spectroscopy and isothermal titration calorimetry.

    Science.gov (United States)

    Makowska, Joanna; Żamojć, Krzysztof; Wyrzykowski, Dariusz; Uber, Dorota; Wierzbicka, Małgorzata; Wiczk, Wiesław; Chmurzyński, Lech

    2016-01-15

    Steady-state and time-resolved fluorescence quenching measurements supported by Isothermal Titration Calorimetry (ITC) were used to study the interactions of Cu(2+) with four peptides. Two of them were taken from the N-terminal part of the FBP28 protein (formin binding protein) WW domain: Tyr-Lys-Thr-Ala-Asp-Gly-Lys-Thr-Tyr-NH2 (D9) and its mutant Tyr-Lys-Thr-Ala-Asn-Gly-Lys-Thr-Tyr-NH2 (D9_M) as well as two mutated peptides from the B3 domain of the immunoglobulin binding protein G derived from Streptococcus: Asp-Val-Ala-Thr-Tyr-Thr-NH2 (J1) and Glu-Val-Ala-Thr-Tyr-Thr-NH2 (J2). The measurements were carried out at 298.15K in 20mM 2-(N-morpholino)ethanesulfonic acid (MES) buffer solution with a pH of 6. The fluorescence of all peptides was quenched by Cu(2+) ions. The stoichiometry, conditional stability constants and thermodynamic parameters for the interactions of the Cu(2+) ions with D9 and D9_M were determined from the calorimetric data. The values of the conditional stability constants were additionally determined from fluorescence quenching measurements and compared with those obtained from calorimetric studies. There was a good correlation between data obtained from the two techniques. On the other hand, the studies revealed that J1 and J2 do not exhibit an affinity towards metal ions. The obtained results prove that fluorescence quenching experiments may be successfully used in order to determine stability constants of complexes with fluorescent ligands. Finally, based on the obtained results, the coordinating properties of the peptides towards the Cu(2+) ions are discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Differential scanning calorimetry (DSC) and temperature-modulated DSC study of three mouthguard materials.

    Science.gov (United States)

    Meng, Frank H; Schricker, Scott R; Brantley, William A; Mendel, Deborah A; Rashid, Robert G; Fields, Henry W; Vig, Katherine W L; Alapati, Satish B

    2007-12-01

    Employ differential scanning calorimetry (DSC) and temperature-modulated DSC (TMDSC) to investigate thermal transformations in three mouthguard materials and provide insight into their previously investigated energy absorption. Samples (13-21mg) were obtained from (a) conventional ethylene vinyl acetate (EVA), (b) Pro-form, another EVA polymer, and (c) PolyShok, an EVA polymer containing polyurethane. Conventional DSC (n=5) was first performed from -80 to 150 degrees C at a heating rate of 10 degrees C/min to determine the temperature range for structural transformations. Subsequently, TMDSC (n=5) was performed from -20 to 150 degrees C at a heating rate of 1 degrees C/min. Onset and peak temperatures were compared using ANOVA and the Tukey-Kramer HSD test. Other samples were coated with a gold-palladium film and examined with an SEM. DSC and TMDSC curves were similar for both conventional EVA and Pro-form, showing two endothermic peaks suggestive of melting processes, with crystallization after the higher-temperature peak. Evidence for crystallization and the second endothermic peak were much less prominent for PolyShok, which had no peaks associated with the polyurethane constituent. The onset of the lower-temperature endothermic transformation is near body temperature. No glass transitions were observed in the materials. SEM examination revealed different surface morphology and possible cushioning effect for PolyShok, compared to Pro-form and EVA. The difference in thermal behavior for PolyShok is tentatively attributed to disruption of EVA crystal formation, which may contribute to its superior impact resistance. The lower-temperature endothermic peak suggests that impact testing of these materials should be performed at 37 degrees C.

  5. Interaction between vitamin D 2 and magnesium in liposomes: Differential scanning calorimetry and FTIR spectroscopy studies

    Science.gov (United States)

    Toyran, Neslihan; Severcan, Feride

    2007-08-01

    Magnesium (Mg 2+) ion is of great importance in physiology by its intervention in 300 enzymatic systems, its role in membrane structure, its function in neuromuscular excitability and vitamin D metabolism and/or action. In the present study, the interaction of Mg 2+, at low (1 mole %) and high (7 mole %) concentrations with dipalmitoyl phosphatidylcholine (DPPC) liposomes has been studied in the presence and absence of vitamin D 2 (1 mole %) by using two noninvasive techniques, namely differential scanning calorimetry (DSC) and Fourier transform infrared (FTIR) spectroscopy. DSC studies reveal that the presence of vitamin D 2 in the pure or Mg 2+ (at both low and high concentrations) containing liposomes diminishes the pretransition. The calorimetric results also reveal that, inclusion of Mg 2+ (more significantly at high concentration) into pure or vitamin D 2 containing DPPC liposomes increases the main phase transition temperature. The investigation of the CH 2 symmetric, the CH 3 asymmetric, the C dbnd O stretching, and the PO2- antisymmetric double bond stretching bands in FTIR spectra with respect to changes occurring in the wavenumber and/or the bandwidth values as a function of temperature reveal that, inclusion of vitamin D 2 or Mg 2+ into pure DPPC liposomes orders and decreases the dynamics of the acyl chains in both gel and liquid-crystalline phases and does not induce hydrogen bond formation in the interfacial region. Furthermore, the dynamics of the head groups of the liposomes decreases in both phases. Our findings reveal that, simultaneous presence of vitamin D 2 and Mg 2+ alters the effect of each other, which is reflected as a decrease in the interactions between these two additives within the model membrane.

  6. New developments in calorimetry and thermal analysis above 2000 °C

    Science.gov (United States)

    Navrotsky, A.; Ushakov, S.; Kapush, D.; Pavlik, A.; Fyhrie, M.

    2016-12-01

    Thermochemical and structural data above 2000 °C for many refractory oxides, including those of the rare earths, are largely absent. Fusion enthalpies are essential for modeling igneous processes, as are volume changes and enthalpies of high temperature phase transitions . The following set of new experimental techniques has been developed for high temperature studies: i) A commercial ultra-high-temperature differential thermal analyzer (DTA)was modified for use to 2500 °C with sealed crucibles and enthalpies of fusion for La2O3 X-phase (78 kJ/mol at 2300 °C), LaAlO3 perovskite (124 kJ/mol at 2134 °C), MgAl2O4 spinel (180 kJ/mol at 2113 °C) were successfully measured. ii) X-ray and neutron diffraction on crystalline laser heated levitated samples has been used to obtain thermal expansion, refine high temperature crystal structure and for in situ study of phase transitions and melting in variable atmospheres using levitators at the Advanced Photon Source and the Spallation Neutron Source. Pre-melting phase transitions in Y2O3, Ho2O3 and Er2O3 from cubic bixbyite-type structures to disordered hexagonal phases are accompanied by 3-4 % decrease in volume. iii) Drop-and-catch (DnC) calorimetry on laser heated aerodynamically levitated samples was developed to allow direct measurement of fusion enthalpies in various atmospheres. The DnC technique was validated by measurement of fusion enthalpy of Al2O3 corundum (120 kJ/mol at 2054 °C) and used to measure fusion enthalpy of cubic bixbyite type Y2O3 (119 kJ/mol at 2430 °C) and Yb2O3 (97 kJ/mol at 2435 °C). Further methodologiccal improvements and applications to earth and planetary materials are discussed.

  7. Digital holographic interferometry: A novel optical calorimetry technique for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cavan, Alicia, E-mail: alicia.cavan@cdhb.health.nz [Department of Physics and Astronomy, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand and Christchurch Hospital, Private Bag 4710, Christchurch 8140 (New Zealand); Meyer, Juergen, E-mail: juergen@uw.edu [Department of Radiation Oncology, University of Washington, 1959 Northeast Pacific Street, Box 356043, Seattle, Washington 98195 (United States)

    2014-02-15

    Purpose: To develop and demonstrate the proof-of-principle of a novel optical calorimetry method to determine radiation absorbed dose in a transparent medium. Methods: The calorimetric property of water is measured during irradiation by means of an interferometer, which detects temperature-induced changes in the refractive index that can be mathematically related to absorbed dose. The proposed method uses a technique called digital holographic interferometry (DHI), which comprises an optical laser interferometer setup and consecutive physical reconstruction of the recorded wave fronts by means of the Fresnel transform. This paper describes the conceptual framework and provides the mathematical basis for DHI dosimetry. Dose distributions from a high dose rate Brachytherapy source were measured by a prototype optical setup to demonstrate the feasibility of the approach. Results: The developed DHI dosimeter successfully determined absorbed dose distributions in water in the region adjacent to a high dose rate Brachytherapy source. A temperature change of 0.0381 K across a distance of 6.8 mm near the source was measured, corresponding to a dose of 159.3 Gy. The standard deviation in a typical measurement set was ±3.45 Gy (corresponding to an uncertainty in the temperature value of ±8.3 × 10{sup −4} K). The relative dose fall off was in agreement with treatment planning system modeled data. Conclusions: First results with a prototype optical setup and a Brachytherapy source demonstrate the proof-of-principle of the approach. The prototype achieves high spatial resolution of approximately 3 × 10{sup −5} m. The general approach is fundamentally independent of the radiation type and energy. The sensitivity range determined indicates that the method is predominantly suitable for high dose rate applications. Further work is required to determine absolute dose in all three dimensions.

  8. Determination of the thermodynamic properties of complexation and extraction by micro-calorimetry

    International Nuclear Information System (INIS)

    Charbonnel, M.Ch.; Flandin, J.L.

    2000-01-01

    The CEA is currently developing the DIAMEX process, the first step in the strategy for the separation of minor actinides from high-level radioactive waste. The extractant belongs to the diamide family of molecules and is able to co-extract trivalent actinides and lanthanides. This study focuses on the thermodynamic properties (ΔH, ΔG, ΔS) of lanthanide extraction by malonamide in order to better understand the mechanisms involved and to account for differences in the behavior of various diamide extractants. The main technique used is microcalorimetric titration. The Thermal Activity Monitor (TAM) microcalorimeter is a modular system with a highly stable (± 0.1 mK) temperature-controlled bath containing up to four calorimetry vessel units. The sensor bulbs inserted in the reaction vessel can measure heat flows in static or dynamic conditions. Micro-calorimetry, and calorimetric titration in particular, is a fast growing field due to technical improvements in both hardware and software. In the case of an equilibrium reaction, titration allows both Δ r G and Δ r H (and thus Δ r S) to be determined simultaneously. It was decided to initiate this thermochemical investigation with a homogeneous phase reaction, and the first study concerned the aqueous phase complexation of a trivalent lanthanide ion by a water-soluble diamide, tetraethyl-malonamide (TEMA: (C 2 H 5 ) 2 NCO-CH 2 CON(C 2 H 5 ) 2 ). In the test system, the heat of dilution of the diamide in water is preponderant over the heat arising from the complexation reaction; the result is a positive value corresponding to an endothermic reaction. However, the equilibration constant K and Δ H are both very small, and cannot be calculated from the resulting Q v f(n TEMA ) curves. Moreover, in aqueous phase, the reactions involved are different from those observed when neodymium(III) is extracted into an organic phase, and the medium must be further characterized before the calorimetry data can be fully

  9. Scan-rate dependence in protein calorimetry: the reversible transitions of Bacillus circulans xylanase and a disulfide-bridge mutant.

    OpenAIRE

    Davoodi, J.; Wakarchuk, W. W.; Surewicz, W. K.; Carey, P. R.

    1998-01-01

    The stabilities of Bacillus circulans xylanase and a disulfide-bridge-containing mutant (S100C/N148C) were investigated by differential scanning calorimetry (DSC) and thermal inactivation kinetics. The thermal denaturation of both proteins was found to be irreversible, and the apparent transition temperatures showed a considerable dependence upon scanning rate. In the presence of low (nondenaturing) concentrations of urea, calorimetric transitions were observed for both proteins in the second...

  10. Measurement of the thermophysical properties of industrial liquid metallic alloys by non-contact calorimetry under reduced gravity

    International Nuclear Information System (INIS)

    Wunderlich, R.K.; Fecht, H.-J.

    2001-01-01

    Full Text: The numerical modeling of casting and solidification is becoming of increased importance in industrial process design. While the numerical algorithms have made large progress towards real process design and optimization, there is a pronounced lack of precise thermophysical input data. This lack is caused by the high chemical reactivity of many metallic alloys in the liquid phase making conventional measurement techniques such as differential thermal analysis difficult if at all possible to apply. In this contribution we report about a project planning to use containerless electromagnetic processing under reduced gravity conditions for thermophysical property measurement of industrially relevant alloys. Alloys of interest are, among others, Ti-alloys, Ni-base superalloys, and steels. In preparation of this project, a survey among leading European industries was conducted revealing properties such as melting range, fraction solid/liquid, specific heat capacity, enthalpy, as well as density, viscosity and surface tension as properties most in need. Non-contact calorimetry of electromagnetically levitated specimens was developed for an investigation of the thermophysical properties of Zr-alloys in the liquid phase. These methods have been applied successfully under reduced gravity conditions on board spacelab to the measurement of the specific heat capacity by modulation calorimetry, the enthalpy of fusion, the total hemispherical emissivity and for an effective thermal conductivity. Specific examples from these experiments demonstrating the applicability of these methods for quantitative calorimetry as well as application at higher Biot numbers will be discussed. New developments include modulation calorimetry in the two phase region for the measurement of the fraction solid. (author)

  11. Accuracy of bone SPECT/CT for identifying hardware loosening in patients who underwent lumbar fusion with pedicle screws

    Energy Technology Data Exchange (ETDEWEB)

    Hudyana, Hendrah; Maes, Alex [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); University Hospital Leuven, Department of Morphology and Medical Imaging, Leuven (Belgium); Vandenberghe, Thierry; Fidlers, Luc [AZ Groeninge, Department of Neurosurgery, Kortrijk (Belgium); Sathekge, Mike [University of Pretoria, Department of Nuclear Medicine, Pretoria (South Africa); Nicolai, Daniel [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); Wiele, Christophe van de [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); University Ghent, Department of Radiology and Nuclear Medicine, Ghent (Belgium)

    2016-02-15

    The aim of this retrospective study was to evaluate the accuracy of bone SPECT (single photon emission computed tomography)/CT (computed tomography) in diagnosing loosening of fixation material in patients with recurrent or persistent back pain that underwent lumbar arthrodesis with pedicle screws using surgery and clinical follow-up as gold standard A total of 48 patients (median age 49 years, range 21-81 years; 17 men) who had undergone lumbar spinal arthrodesis were included in this retrospective analysis. SPECT/CT results were compared to the gold standard of surgical evaluation or clinical follow-up. Positive SPECT/CT results were considered true positives if findings were confirmed by surgery or if clinical and other examinations were completely consistent with the positive SPECT/CT finding. They were considered false positives if surgical evaluation did not find any loose pedicle screws or if symptoms subsided with non-surgical therapy. Negative SPECT/CT scans were considered true negatives if symptoms either improved without surgical intervention or remained stable over a minimum follow-up period of 6 months. Negative SPECT/CT scans were determined to be false negatives if surgery was still required and loosening of material was found. The median length of time from primary surgery to bone SPECT/CT referral was 29.5 months (range 12-192 months). Median follow-up was 18 months (range 6-57) for subjects who did not undergo surgery. Thirteen of the 48 patients were found to be positive for loosening on bone SPECT/CT. Surgical evaluation (8 patients) and clinical follow-up (5 patients) showed that bone SPECT/CT correctly predicted loosening in 9 of 13 patients, while it falsely diagnosed loosening in 4 patients. Of 35 negative bone SPECT/CT scans, 12 were surgically confirmed. In 18 patients, bone SPECT/CT revealed lesions that could provide an alternative explanation for the symptoms of pain (active facet degeneration in 14 patients, and disc and sacroiliac

  12. Indirect Tire Monitoring System - Machine Learning Approach

    Science.gov (United States)

    Svensson, O.; Thelin, S.; Byttner, S.; Fan, Y.

    2017-10-01

    The heavy vehicle industry has today no requirement to provide a tire pressure monitoring system by law. This has created issues surrounding unknown tire pressure and thread depth during active service. There is also no standardization for these kind of systems which means that different manufacturers and third party solutions work after their own principles and it can be hard to know what works for a given vehicle type. The objective is to create an indirect tire monitoring system that can generalize a method that detect both incorrect tire pressure and thread depth for different type of vehicles within a fleet without the need for additional physical sensors or vehicle specific parameters. The existing sensors that are connected communicate through CAN and are interpreted by the Drivec Bridge hardware that exist in the fleet. By using supervised machine learning a classifier was created for each axle where the main focus was the front axle which had the most issues. The classifier will classify the vehicles tires condition and will be implemented in Drivecs cloud service where it will receive its data. The resulting classifier is a random forest implemented in Python. The result from the front axle with a data set consisting of 9767 samples of buses with correct tire condition and 1909 samples of buses with incorrect tire condition it has an accuracy of 90.54% (0.96%). The data sets are created from 34 unique measurements from buses between January and May 2017. This classifier has been exported and is used inside a Node.js module created for Drivecs cloud service which is the result of the whole implementation. The developed solution is called Indirect Tire Monitoring System (ITMS) and is seen as a process. This process will predict bad classes in the cloud which will lead to warnings. The warnings are defined as incidents. They contain only the information needed and the bandwidth of the incidents are also controlled so incidents are created within an

  13. Direct and indirect detection of supersymmetric dark matter; Detection directe et indirecte de matiere sombre supersymetrique

    Energy Technology Data Exchange (ETDEWEB)

    Mayet, F

    2001-09-01

    A substantial body of astrophysical evidence supports the existence of non-baryonic dark matter in the universe. One of the leading dark matter candidates is the neutralino predicted by the supersymmetric extensions of the standard model of particle physics. Different detectors have been designed for the detection, either indirect or direct, of the neutralino. Related to indirect detection, the present work has been performed in the context of the AMS experiment. A precursor version of the spectrometer was flown on the space shuttle Discovery in June 1998. The detector included an Aerogel Threshold Cherenkov counter (ATC) to identify antiprotons, whose spectrum may be used to infer a neutralino signal. The analysis of the ATC data is presented including an evaluation of the flight performance and a description of the optimization of the antiproton selection. An antiproton analysis is also reported. A phenomenological study allows us to investigate the discovery potential of this indirect method. This thesis also includes the development of a new detector (MACHe3) designed for direct neutralino search using a superfluid {sup 3}He bolometer operated at ultra low temperatures. The data analysis of the prototype cell is presented. A Monte Carlo simulation has been developed, in order to optimize the detector design for direct neutralino search. These results are compared with theoretical predictions of supersymmetric models, thus highlighting the discovery potential of this detector and its complementarity with existing devices. (author)

  14. Tears of the Supraspinatus Tendon: Assessment with Indirect Magnetic Resonance Arthrography in 67 Patients with Arthroscopic Correlation

    International Nuclear Information System (INIS)

    Dyck, P. van; Gielen, J.L.; Parizel, P.M.

    2009-01-01

    Background: Magnetic resonance (MR) arthrography is generally regarded as the gold standard for shoulder imaging. As an alternative to direct MR arthrography, the less invasive indirect MR arthrography technique was proposed, offering logistic advantages because fluoroscopic or ultrasonographic guidance for joint injection is not required. Purpose: To assess the diagnostic performance of indirect MR arthrography in the diagnosis of full- and partial-thickness supraspinatus tears in a symptomatic population. Material and Methods: Two radiologists with different levels of experience independently and retrospectively interpreted indirect MR (1.5T) arthrograms of the shoulder obtained in 67 symptomatic patients who underwent subsequent arthroscopy. On MR, the supraspinatus tendon was evaluated for full- or partial-thickness tear. With arthroscopy as the standard of reference, sensitivity, specificity, and diagnostic accuracy of indirect MR arthrography in the detection of full- and partial-thickness tears of the supraspinatus tendon was calculated. Kappa (κ) statistics were used for the assessment of the agreement between arthroscopic and imaging findings and for the assessment of interobserver agreement. Results: For full-thickness tears of the supraspinatus tendon, sensitivities, specificities, and accuracies exceeded 90% for both observers, with excellent interobserver agreement (κ = 0.910). For partial-thickness tears, sensitivities (38-50%) and accuracies (76-78%) were poor for both reviewers, and interobserver agreement was moderate (κ = 0.491). Discrepancies between MR diagnosis and arthroscopy were predominantly observed with small partial-thickness tears. Conclusion: Indirect MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears. However, the diagnosis of partial-thickness tears with indirect MR arthrography remains faulty, because exact demarcation of degenerative change and partial rupture is difficult. On the basis of

  15. Tears of the Supraspinatus Tendon: Assessment with Indirect Magnetic Resonance Arthrography in 67 Patients with Arthroscopic Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Dyck, P. van; Gielen, J.L.; Parizel, P.M. (Dept. of Radiology, Univ. Hospital Antwerp and Univ. of Antwerp, Antwerp (Belgium)) (and others)

    2009-11-15

    Background: Magnetic resonance (MR) arthrography is generally regarded as the gold standard for shoulder imaging. As an alternative to direct MR arthrography, the less invasive indirect MR arthrography technique was proposed, offering logistic advantages because fluoroscopic or ultrasonographic guidance for joint injection is not required. Purpose: To assess the diagnostic performance of indirect MR arthrography in the diagnosis of full- and partial-thickness supraspinatus tears in a symptomatic population. Material and Methods: Two radiologists with different levels of experience independently and retrospectively interpreted indirect MR (1.5T) arthrograms of the shoulder obtained in 67 symptomatic patients who underwent subsequent arthroscopy. On MR, the supraspinatus tendon was evaluated for full- or partial-thickness tear. With arthroscopy as the standard of reference, sensitivity, specificity, and diagnostic accuracy of indirect MR arthrography in the detection of full- and partial-thickness tears of the supraspinatus tendon was calculated. Kappa (kappa) statistics were used for the assessment of the agreement between arthroscopic and imaging findings and for the assessment of interobserver agreement. Results: For full-thickness tears of the supraspinatus tendon, sensitivities, specificities, and accuracies exceeded 90% for both observers, with excellent interobserver agreement (kappa = 0.910). For partial-thickness tears, sensitivities (38-50%) and accuracies (76-78%) were poor for both reviewers, and interobserver agreement was moderate (kappa = 0.491). Discrepancies between MR diagnosis and arthroscopy were predominantly observed with small partial-thickness tears. Conclusion: Indirect MR arthrography is highly accurate in the diagnosis of full-thickness rotator cuff tears. However, the diagnosis of partial-thickness tears with indirect MR arthrography remains faulty, because exact demarcation of degenerative change and partial rupture is difficult. On the

  16. Performance comparison of direct and indirect lighting systems

    International Nuclear Information System (INIS)

    Rubinstein, F.; Morse, O.; Clark, T.

    1993-01-01

    The performance of a retrofitted indirect lighting system was compared to the performance of a typical de-lamped direct lighting system in a partitioned office space. Power, illuminance and luminance measurements were made for the de-lamped direct lighting system and after installation of the indirect lighting system with various lamp and ballast combinations. Using the same lamps and ballasts, average workplace illuminance was slightly higher with indirect lighting than with direct lighting. With indirect lighting, workplace lumen efficacy was 4.5% lower due to the higher power draw of the lamps in the more open and cooler indirect fixtures. Indirect lighting with 36 watt T-8 lamps and electronic ballasts achieved an initial average workplace illuminance of 45 foot-candles in the partitioned office space at only 1.1 w/ft 2

  17. Direct and indirect punishment among strangers in the field.

    Science.gov (United States)

    Balafoutas, Loukas; Nikiforakis, Nikos; Rockenbach, Bettina

    2014-11-11

    Many interactions in modern human societies are among strangers. Explaining cooperation in such interactions is challenging. The two most prominent explanations critically depend on individuals' willingness to punish defectors: In models of direct punishment, individuals punish antisocial behavior at a personal cost, whereas in models of indirect reciprocity, they punish indirectly by withholding rewards. We investigate these competing explanations in a field experiment with real-life interactions among strangers. We find clear evidence of both direct and indirect punishment. Direct punishment is not rewarded by strangers and, in line with models of indirect reciprocity, is crowded out by indirect punishment opportunities. The existence of direct and indirect punishment in daily life indicates the importance of both means for understanding the evolution of cooperation.

  18. Indirect land use change and biofuel policy

    International Nuclear Information System (INIS)

    Kocoloski, Matthew; Griffin, W Michael; Matthews, H Scott

    2009-01-01

    Biofuel debates often focus heavily on carbon emissions, with parties arguing for (or against) biofuels solely on the basis of whether the greenhouse gas emissions of biofuels are less than (or greater than) those of gasoline. Recent studies argue that land use change leads to significant greenhouse gas emissions, making some biofuels more carbon intensive than gasoline. We argue that evaluating the suitability and utility of biofuels or any alternative energy source within the limited framework of plus and minus carbon emissions is too narrow an approach. Biofuels have numerous impacts, and policy makers should seek compromises rather than relying solely on carbon emissions to determine policy. Here, we estimate that cellulosic ethanol, despite having potentially higher life cycle CO 2 emissions (including from land use) than gasoline, would still be cost-effective at a CO 2 price of $80 per ton or less, well above estimated CO 2 mitigation costs for many alternatives. As an example of the broader approach to biofuel policy, we suggest the possibility of using the potential cost reductions of cellulosic ethanol relative to gasoline to balance out additional carbon emissions resulting from indirect land use change as an example of ways in which policies could be used to arrive at workable solutions.

  19. Spherical cows in dark matter indirect detection

    Energy Technology Data Exchange (ETDEWEB)

    Bernal, Nicolás [Centro de Investigaciones, Universidad Antonio Nariño, Cra 3 Este # 47A-15, Bogotá (Colombia); Necib, Lina; Slatyer, Tracy R., E-mail: nicolas.bernal@uan.edu.co, E-mail: lnecib@mit.edu, E-mail: tslatyer@mit.edu [Center for Theoretical Physics, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States)

    2016-12-01

    Dark matter (DM) halos have long been known to be triaxial, but in studies of possible annihilation and decay signals they are often treated as approximately spherical. In this work, we examine the asymmetry of potential indirect detection signals of DM annihilation and decay, exploiting the large statistics of the hydrodynamic simulation Illustris. We carefully investigate the effects of the baryons on the sphericity of annihilation and decay signals for both the case where the observer is at 8.5 kpc from the center of the halo (exemplified in the case of Milky Way-like halos), and for an observer situated well outside the halo. In the case of Galactic signals, we find that both annihilation and decay signals are expected to be quite symmetric, with axis ratios very different from 1 occurring rarely. In the case of extragalactic signals, while decay signals are still preferentially spherical, the axis ratio for annihilation signals has a much flatter distribution, with elongated profiles appearing frequently. Many of these elongated profiles are due to large subhalos and/or recent mergers. Comparing to gamma-ray emission from the Milky Way and X-ray maps of clusters, we find that the gamma-ray background appears less spherical/more elongated than the expected DM signal from the large majority of halos, and the Galactic gamma ray excess appears very spherical, while the X-ray data would be difficult to distinguish from a DM signal by elongation/sphericity measurements alone.

  20. Indirectly cooled large thin superconducting CDF solenoid

    International Nuclear Information System (INIS)

    Kondo, Kunitaka; Mori, Shigeki; Yoshizaki, Ryozo; Saito, Ryusei; Asano, Katsuhiko.

    1985-01-01

    The manufacturing technique of the indirectly cooled large thin superconducting solenoid for the collider detector facility (CDF solenoid) has been studied through cooperation of University of Tsukuba and the National Laboratory for High Energy Physics of the Ministry of Education of Japan, and the Fermi National Accelerator Laboratory in the U.S. Fabrication and testing of the solenoid has recently been completed by Hitachi. The CDF solenoid has a large-sized thin structure for meeting the requirement by experiments to be applied. Hitachi has thus developed a variety of new technologies including the design standard, coil cooling method, material selection, and manufacturing technique in accordance with experimental data, which were confirmed in a series of analyses and tests made on various prototypes. The CDF solenoid, built using Hitachi's new technologies, is of the world's top class among equipment of this type. This paper outlines the design criteria for the major components employed in the CDF solenoid and the test results of the solenoid. (author)