WorldWideScience

Sample records for underwent endovascular stent-graft

  1. Endovascular stent-graft management of thoracic aortic diseases

    International Nuclear Information System (INIS)

    Dake, Michael D.

    2001-01-01

    The traditional standard therapy for descending thoracic aortic aneurysm (TAA) is open operative repair with graft replacement of the diseased aortic segment. Despite important advances in surgical techniques, anesthetic management, and post-operative care over the last 30 years, the mortality and morbidity of surgery remains considerable, especially in patients at high risk for thoracotomy because of coexisting severe cardiopulmonary abnormalities or other medical diseases. The advent of endovascular stent-graft technology provides an alternative to open surgery for selected patients with TAA. The initial experience suggests that stent-graft therapy potentially may reduce the operative risk, hospital stay and procedural expenses of TAA repair. These potential benefits are especially attractive for patients at high risk for open TAA repair. Current results of endovascular TAA therapy document operative mortalities of between 0 and 4%, aneurysm thrombosis in 90 and 100% of cases, and paraplegia as a complication in 0 and 1.6% of patients. The early success of stent-graft repair of TAA has fostered the application of these devices for the management of a wide variety of thoracic aortic pathologies, including acute and chronic dissection, intramural hematoma, penetrating ulcer, traumatic injuries, and other diseases. The results of prospective controlled trials that compare the outcomes of stent-graft therapy with those of surgical treatment in patients with specific types of aortic disease are anxiously awaited before recommendations regarding the general use of these new devices can be made with confidence

  2. Infolding of fenestrated endovascular stent graft.

    Science.gov (United States)

    Zelt, Jason G E; Jetty, Prasad; Hadziomerovic, Adnan; Nagpal, Sudhir

    2017-09-01

    We report a case of infolding of a fenestrated stent graft involving the visceral vessel segment after a juxtarenal abdominal aorta aneurysm repair. The patient remains free of any significant endoleak, and the aortic sac has shown regression. The patient remains asymptomatic, with no abdominal pain, with normal renal function, and without ischemic limb complications. We hypothesize that significant graft oversizing (20%-30%) with asymmetric engineering of the diameter-reducing ties may have contributed to the infolding. Because of the patient's asymptomatic nature and general medical comorbidities, further intervention was deemed inappropriate as the aneurysmal sac is regressing despite the infolding.

  3. Endovascular stent graft treatment of acute thoracic aortic transections due to blunt force trauma.

    LENUS (Irish Health Repository)

    Bjurlin, Marc A

    2012-02-01

    Endovascular stent graft treatment of acute thoracic aortic transections is an encouraging minimally invasive alternative to open surgical repair. Between 2006 and 2008, 16 patients with acute thoracic aortic transections underwent evaluation at our institution. Seven patients who were treated with an endovascular stent graft were reviewed. The mean Glasgow Coma Score was 13.0, probability of survival was .89, and median injury severity score was 32. The mean number of intensive care unit days was 7.7, mean number of ventilator support days was 5.4, and hospital length of stay was 10 days. Mean blood loss was 285 mL, and operative time was 143 minutes. Overall mortality was 14%. Procedure complications were a bleeding arteriotomy site and an endoleak. Endovascular treatment of traumatic thoracic aortic transections appears to demonstrate superior results with respect to mortality, blood loss, operative time, paraplegia, and procedure-related complications when compared with open surgical repair literature.

  4. Endovascular Tubular Stent-Graft Placement for Isolated Iliac Artery Aneurysms

    International Nuclear Information System (INIS)

    Okada, Takuya; Yamaguchi, Masato; Kitagawa, Atsushi; Kawasaki, Ryota; Nomura, Yoshikatsu; Okita, Yutaka; Sugimura, Kazuro; Sugimoto, Koji

    2012-01-01

    Purpose: To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Materials and Methods: Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non–contrast-enhanced CT was performed in seven patients with chronic kidney disease. Results: All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47–2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p < 0.05) decreased from 42.0 (9.3) to 36.9 (13.6) mm and from 40.1 (13.0) to 33.6 (15.8) mm, respectively; the mean (SD) shrinkage rates were 15.1% (20.2%) and 18.9% (22.4%), respectively. The primary patency rate was 100%, and no secondary interventions were required. Four patients (21%) developed transient buttock claudication, and one patient (5%) developed colorectal ischaemia, which was treated conservatively. Conclusion: Endovascular tubular stent-graft placement for the repair of isolated IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.

  5. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy.

  6. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  7. Long-term Results of Endovascular Stent Graft Placement of Ureteroarterial Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Takuya, E-mail: okabone@gmail.com; Yamaguchi, Masato, E-mail: masato03310402@yahoo.co.jp [Kobe University Hospital, Department of Radiology (Japan); Muradi, Akhmadu, E-mail: muradiakhmadu@gmail.com; Nomura, Yoshikatsu, E-mail: y_katsu1027@yahoo.co.jp [Kobe University Hospital, Center for Endovascular Therapy (Japan); Uotani, Kensuke, E-mail: uotani@tenriyorozu.jp [Tenri Hospital, Department of Radiology (Japan); Idoguchi, Koji, E-mail: idoguchi@ares.eonet.ne.jp [Kobe University Hospital, Center for Endovascular Therapy (Japan); Miyamoto, Naokazu, E-mail: naoka_zu@yahoo.co.jp; Kawasaki, Ryota, E-mail: kawaryo1999@yahoo.co.jp [Hyogo Brain and Heart Center at Himeji, Department of Radiology (Japan); Taniguchi, Takanori, E-mail: tan9523929@yahoo.co.jp [Tenri Hospital, Department of Radiology (Japan); Okita, Yutaka, E-mail: yokita@med.kobe-u.ac.jp [Kobe University Hospital, Department of Cardiovascular Surgery (Japan); Sugimoto, Koji, E-mail: kojirad@med.kobe-u.ac.jp [Kobe University Hospital, Department of Radiology (Japan)

    2013-08-01

    PurposeTo evaluate the safety, efficacy, and long-term results of endovascular stent graft placement for ureteroarterial fistula (UAF).MethodsWe retrospectively analyzed stent graft placement for UAF performed at our institution from 2004 to 2012. Fistula location was assessed by contrast-enhanced computed tomography (CT) and angiography, and freedom from hematuria recurrence and mortality rates were estimated.ResultsStent graft placement for 11 UAFs was performed (4 men, mean age 72.8 {+-} 11.6 years). Some risk factors were present, including long-term ureteral stenting in 10 (91 %), pelvic surgery in 8 (73 %), and pelvic radiation in 5 (45 %). Contrast-enhanced CT and/or angiography revealed fistula or encasement of the artery in 6 cases (55 %). In the remaining 5 (45 %), angiography revealed no abnormality, and the suspected fistula site was at the crossing area between urinary tract and artery. All procedures were successful. However, one patient died of urosepsis 37 days after the procedure. At a mean follow-up of 548 (range 35-1,386) days, 4 patients (36 %) had recurrent hematuria, and two of them underwent additional treatment with secondary stent graft placement and surgical reconstruction. The hematuria recurrence-free rates at 1 and 2 years were 76.2 and 40.6 %, respectively. The freedom from UAF-related and overall mortality rates at 2 years were 85.7 and 54.9 %, respectively.ConclusionEndovascular stent graft placement for UAF is a safe and effective method to manage acute events. However, the hematuria recurrence rate remains high. A further study of long-term results in larger number of patients is necessary.

  8. Contrast Medium Induced Nephropathy after Endovascular Stent Graft Placement: An Examination of Its Prevalence and Risk Factors

    International Nuclear Information System (INIS)

    Kawatani, Yohei; Nakamura, Yoshitsugu; Mochida, Yoshihiko; Yamauchi, Naoya; Hayashi, Yujiro; Taneichi, Tetsuyoshi; Ito, Yujiro; Kurobe, Hirotsugu; Suda, Yuji; Hori, Takaki

    2016-01-01

    Endovascular stent graft placement has become a major treatment for thoracic and abdominal aneurysms. While endovascular therapy is less invasive than open surgery, it involves the use of a contrast medium. Contrast media can cause renal impairment, a condition termed as contrast-induced nephropathy (CIN). This study sought to evaluate the incidence and risk factors of CIN following endovascular stent graft placement for aortic aneurysm repair. The study included 167 consecutive patients who underwent endovascular stent graft placement in our hospital from October 2013 to June 2014. CIN was diagnosed using the European Society of Urogenital Radiology criteria. Patients with and without CIN were compared. Chi-squared tests, t-tests, and multivariate logistic regression analyses were performed. Thirteen patients (7.8%) developed CIN. Left ventricular dysfunction and intraoperative blood transfusion were significantly more frequent in the CIN group (P = 0.017 and P = 0.032, resp.). Multivariate analysis showed that left ventricular dysfunction had the strongest influence on CIN development (odds ratio 9.34, P = 0.018, and 95% CI = 1.46–59.7). Patients with CIN also experienced longer ICU and hospital stays. Measures to improve renal perfusion flow should be considered for patients with left ventricular dysfunction who are undergoing endovascular stent graft placement

  9. Hemodynamic and Anatomic Predictors of Renovisceral Stent-Graft Occlusion Following Chimney Endovascular Repair of Juxtarenal Aortic Aneurysms.

    Science.gov (United States)

    Tricarico, Rosamaria; He, Yong; Laquian, Liza; Scali, Salvatore T; Tran-Son-Tay, Roger; Beck, Adam W; Berceli, Scott A

    2017-12-01

    To identify anatomic and hemodynamic changes associated with impending visceral chimney stent-graft occlusion after endovascular aneurysm repair (EVAR) with the chimney technique (chEVAR). A retrospective evaluation was performed of computed tomography scans from 41 patients who underwent juxtarenal chEVAR from 2008 to 2012 to identify stent-grafts demonstrating conformational changes following initial placement. Six subjects (mean age 74 years; 3 men) were selected for detailed reconstruction and computational hemodynamic analysis; 4 had at least 1 occluded chimney stent-graft. This subset of repairs was systematically analyzed to define the anatomic and hemodynamic impact of these changes and identify signature patterns associated with impending renovisceral stent-graft occlusion. Spatial and temporal analyses of cross-sectional area, centerline angle, intraluminal pressure, and wall shear stress (WSS) were performed within the superior mesenteric and renal artery chimney grafts used for repair. Conformational changes in the chimney stent-grafts and associated perturbations, in both local WSS and pressure, were responsible for the 5 occlusions in the 13 stented branches. Anatomic and hemodynamic signatures leading to occlusion were identified within 1 month postoperatively, with a lumen area 25 Pa/mm (p=0.03), and systolic WSS >45 Pa (p=0.03) associated with future chimney stent-graft occlusion. Chimney stent-grafts at increased risk for occlusion demonstrated anatomic and hemodynamic signatures within 1 month of juxtarenal chEVAR. Analysis of these parameters in the early postoperative period may be useful for identifying and remediating these high-risk stent-grafts.

  10. Endovascular implantation of stent-grafts in the thoracic aorta - mid-term results of a prospective controlled study

    International Nuclear Information System (INIS)

    Duda, S.H.; Pusich, B.; Tepe, G.; Pereira, P.; Feuls, R.; Claussen, C.D.; Raygrotzki, S.; Aebert, H.; Ziemer, G.; Uckmann, F.P.

    2002-01-01

    Purpose: To evaluate the effectiveness and safety of endovascular treatment of various descending thoracic aortic pathologies with covered stent-grafts as an alternative to open surgery. Methods: Among 16 patients (5 type B dissections, 5 contained ruptures, 3 aneurysms of the descending aorta, 1 thoraco-abdominal aneurysm, 1 mural thrombosis, 1 patch aneurysm) treated between November 1997 and November 2000, eight patients received Talent TM stent-grafts and another 8 patients underwent a Gore-TAG TM stent-graft implantation. A clinical follow-up and control CT scans were obtained after the procedure and then at six-month intervals. Results: Deployment of the stent-grafts was technically successful in all cases. Sufficient aortic reconstruction was achieved in all but one patient who needed surgical treatment. One patient died two days after the procedure from aortic rupture due to retrograde type A dissection. Another patient died 19 months after the procedure from an unknown cause. There was no occurrence of distal embolization, paralysis or infection. During follow-up, all patients remained free from recurrence or late complications of their disease. Conclusion: Endoluminal treatment of thoracic aortic pathologies with covered stent-grafts appears to be a safe and feasible method with at least mid-term efficacy. (orig.) [de

  11. Aortic Arch Aneurysms: Treatment with Extra anatomical Bypass and Endovascular Stent-Grafting

    International Nuclear Information System (INIS)

    Kato, Noriyuki; Shimono, Takatsugu; Hirano, Tadanori; Mizumoto, Toru; Ishida, Masaki; Fujii, Hideki; Yada, Isao; Takeda, Kan

    2002-01-01

    Endovascular repair of thoracic aortic aneurysms is emerging as an attractive alternative to surgical graft replacement. However,patients with aortic arch aneurysms are often excluded from the target of endovascular repair because of lack of suitable landing zones, especially at the proximal ones. In this paper we describe our method for treating patients with aortic arch aneurysms using a combination of extra anatomical bypass surgery and endovascular stent-grafting

  12. Immediate endovascular stent-graft repair of an acute traumatic

    African Journals Online (AJOL)

    Enrique

    device intended for abdominal deployment. The stent-graft was manually removed from its short delivery device and ... Largely on the basis of the Parmley report, standard teaching was that these injuries ... 5 mm to allow adequate proximal anchorage. Tactics to ... Temporary hypotension is generally induced during the.

  13. Evolution of the Proximal Sealing Rings of the Anaconda Stent-Graft After Endovascular Aneurysm Repair

    NARCIS (Netherlands)

    Koenrades, Maaike A.; Klein, Almar; Leferink, Anne M.; Slump, Cornelis H.; Geelkerken, Robert H.

    2018-01-01

    Purpose: To provide insight into the evolution of the saddle-shaped proximal sealing rings of the Anaconda stent-graft after endovascular aneurysm repair (EVAR). Methods: Eighteen abdominal aortic aneurysm patients were consecutively enrolled in a single-center, prospective, observational cohort

  14. Clinical application of endovascular stent-graft in the treatment of portal stenosis of cancerous thrombus

    International Nuclear Information System (INIS)

    Jiang Zaibo; Huang Mingsheng; Wang Jing; Li Zhengran; Qian Jiesheng; Guang Shouhai; Zhu Kangshun; Shan Hong; Zhang Xiongjun

    2007-01-01

    Objective: To explore the approach and early effects of endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Methods: Six cases with portal vein stenosis of cancerous thrombus, which caused by primary hepatic carcinoma (5 cases) and cholangiocarcinoma (1 case) and the severity of stenosis showed on contrast enhanced CT were more than 75% or occluded, were performed percutaneous transhepatic or transsplenic portography. FLUENCY TM endovascular stent-graft (10 mm diameter) was placed at the position of stenosis after gastroesophageal varices embolization. Portal pressure was measured pre- and post-deployment. Results: Stents were successfully placed in all patients. The average portal pressure decreased from 50.7 em H 2 O (1 cm H 2 O0.098 kPa) to 41.3 cm H 2 O after endovascular stent-graft deployment. The restenosis were found in 2 cases after one month. Haematemesis and refractory ascites appeared in one case respectively, the other 4 cases showed no significant symptoms above caused by portal hypertension. Conclusion: It is safe and feasible for endovascular stent-graft deployment in the treatment of portal stenosis of cancerous thrombus. Selecting the suitable indications, the symptoms of portal hypertension can be controlled effectively. (authors)

  15. Endovascular stent graft for treatment of complicated spontaneous dissection of celiac artery: Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ung Rae; Lee, Young Hwan [Dept. of Diagnostic Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Hwan [Dept. of Diagnostic Radiology, Dongsan Medical Center, Keimyung University School of Medicine, Daegu (Korea, Republic of)

    2013-06-15

    We report 2 cases of complicated spontaneous dissection of the celiac artery, which were successfully treated by a stent graft. The first patient was a 47-year-old man who presented with acute abdominal pain. CT scan showed ruptured saccular aneurysm with surrounding retroperitoneal hematoma. The second patient was a 57-year-old man with progressive dissecting aneurysm. Endovascular stent graft was placed in the celiac trunk to control bleeding, and to prevent rupture in each patient. Follow-up CT scans showed complete obliteration of a dissecting aneurysm.

  16. Penetrating Atherosclerotic Ulcer of the Descending Thoracic Aorta: Treatment by Endovascular Stent-Graft

    International Nuclear Information System (INIS)

    Murgo, Salvatore; Dussaussois, Luc; Golzarian, Jafar; Cavenaile, Jean Christophe; Abada, Hicham Tarik; Ferreira, Jose; Struyven, Julien

    1998-01-01

    Purpose: To present four cases of penetrating ulcer of the descending thoracic aorta treated by transfemoral insertion of an endoluminal stent-graft. Methods: Four patients with penetrating aortic ulcers were reviewed. Three cases were complicated by rupture, false aneurysm, or retrograde dissection. All patients were treated by endovascular stent-graft and were followed by helical computed tomography (CT). Results: Endovascular stent-graft deployment was successful in all patients. However, in one case we observed a perigraft leak that spontaneously disappeared within the first month, and two interventions were needed for another patient. Following treatment, one episode of transient spinal ischemia was observed. The 30-day survival rate was 100%, but one patient died from pneumonia with cardiac failure 34 days after the procedure. In one patient, helical CT performed at 3 months showed a false aneurysm independent of the first ulcer. This patient refused any further treatment and suddenly died at home (unknown cause) after a 6-month follow-up period. Conclusion: Transluminal placement of endovascular stent-grafts for treatment of penetrating ulcers of the descending thoracic aorta appears to be a possible alternative to classical surgery. After treatment, follow-up by CT is essential to detect possible complications of the disease

  17. Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration?

    Science.gov (United States)

    Malina, M; Lindblad, B; Ivancev, K; Lindh, M; Malina, J; Brunkwall, J

    1998-11-01

    To investigate if stents with hooks and barbs will improve stent-graft fixation in the abdominal aorta. Sixteen- to 24-mm-diameter Dacron grafts were deployed inside cadaveric aortas. The grafts were anchored by stents as in endovascular abdominal aortic aneurysm repair. One hundred thirty-seven stent-graft deployments were carried out with modified self-expanding Z-stents with (A) no hooks and barbs (n = 75), (B) 4 5-mm-long hooks and barbs (n = 39), (C) 8 10-mm-long, strengthened hooks and barbs (n = 19), or (D) hooks only (n = 4). Increasing longitudinal traction was applied to determine the displacement force needed to extract the stent-grafts. The radial force of the stents was measured and correlated to the displacement force. The median (interquartile range) displacement force needed to extract grafts anchored by stent A was 2.5 N (2.0 to 3.4), stent B 7.8 N (7.4 to 10.8), and stent C 22.5 N (17.1 to 27.9), p barbs added anchoring strength. During traction, the weaker barbs were distorted or caused intimal tears. The stronger barbs engaged the entire aortic wall. The radial force of the stents had no impact on fixation, while aortic calcification and graft oversizing had marginal effects. Stent barbs and hooks increased the fixation of stent-grafts tenfold, while the radial force of stents had no impact. These data may prove important in future endograft development to prevent stent-graft migration after aneurysm exclusion.

  18. Retroperitoneal aortic hemorrhage caused by penetration of an endovascular stent-graft anchoring barb.

    Science.gov (United States)

    Twine, Christopher P; Winterbottom, Andrew; Shaida, Nadeem; Boyle, Jonathan R

    2013-08-01

    To report a rare case of acute intraoperative retroperitoneal hemorrhage secondary to aortic penetration by the suprarenal anchoring barb on a stent-graft. A 75-year-old patient on dual antiplatelet therapy for coronary stents and low-molecular-weight heparin for atrial thrombus underwent elective endovascular repair of a 6.7-cm infrarenal abdominal aortic aneurysm. A device with suprarenal fixation and metal anchoring barbs was implanted, and a molding balloon was used that at no time covered the proximal bare metal stents or barbs. In recovery, the patient became tachycardic and hypotensive. After resuscitation, imaging identified an anterior barb penetrating the aortic wall, causing the acute retroperitoneal hemorrhage. A decision to treat conservatively rather than resort to open surgery was difficult but ultimately influenced by the patients' high risk for open surgery. The patient was treated by aggressive reversal of heparin and platelet transfusion, and the bleed settled spontaneously. Major surgery and subsequent morbidity may be avoided by medical management of what would appear to be a surgical problem.

  19. Endovascular Treatment of Ruptured Abdominal Aneurysm into the Inferior Vena Cava in Patient After Stent Graft Placement

    International Nuclear Information System (INIS)

    Juszkat, Robert; Pukacki, Fryderyk; Zarzecka, Anna; Kulesza, Jerzy; Majewski, Waclaw

    2009-01-01

    We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The procedure was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.

  20. Acute Symptomatic Abdominal Aortic Aneurysm Secondary to Endovascular Stent Graft Associated Type II Endoleak

    Directory of Open Access Journals (Sweden)

    Karen Ka Leung Chan

    2006-07-01

    Full Text Available Endovascular abdominal aneurysm repair (EVAR is popular because of its low invasiveness and feasibility for high-risk patients. Endoleak is common after EVAR and is characterized by blood flow within the aneurysm sac but outside the stent graft. Type II or collateral endoleak commonly results from retrograde filling of the aneurysm from collateral visceral vessels, lumbar, inferior mesenteric, accessory renal or sacral arteries. Collateral leaks are generally thought to be benign and over half of the early leaks will seal spontaneously. Sporadically, collateral endoleak could lead to aneurysm sac pressurization and place the patient at ongoing risk of rupture. Herein, we report an uncommon case of early post-stent graft placement symptomatic abdominal aortic aneurysm associated with type II endoleak.

  1. Endovascular Treatment of Descending Thoracic Aortic Aneurysms with the EndoFit Stent-Graft

    International Nuclear Information System (INIS)

    Saratzis, N.; Saratzis, Athanasios; Melas, N.; Ginis, G.; Lioupis, A.; Lykopoulos, D.; Lazaridis, J.; Kiskinis, Dimitrios

    2007-01-01

    Objective. To evaluate the mid-term feasibility, efficacy, and durability of descending thoracic aortic aneurysm (DTAA) exclusion using the EndoFit device (LeMaitre Vascular). Methods. Twenty-three (23) men (mean age 66 years) with a DTAA were admitted to our department for endovascular repair (21 were ASA III+ and 2 refused open repair) from January 2003 to July 2005. Results. Complete aneurysm exclusion was feasible in all subjects (100% technical success). The median follow-up was 18 months (range 8-40 months). A single stent-graft was used in 6 cases. The deployment of a second stent-graft was required in the remaining 17 patients. All endografts were attached proximally, beyond the left subclavian artery, leaving the aortic arch branches intact. No procedure-related deaths have occurred. A distal type I endoleak was detected in 2 cases on the 1 month follow-up CT scan, and was repaired with reintervention and deployment of an extension graft. A nonfatal acute myocardial infarction occurred in 1 patient in the sixth postoperative month. Graft migration, graft infection, paraplegia, cerebral or distal embolization, renal impairment or any other major complications were not observed. Conclusion. The treatment of DTAAs using the EndoFit stent-graft is technically feasible. Mid-term results in this series are promising

  2. Open Versus Endovascular Stent Graft Repair of Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Firwana, Belal; Ferwana, Mazen; Hasan, Rim

    2014-01-01

    We performed an analysis to assess the need for conducting additional randomized controlled trials (RCTs) comparing open and endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA). Trial sequential analysis (TSA) is a statistical methodology that can calculate the required inform...

  3. Endovascular treatment of penetrating arterial trauma with stent grafts.

    Science.gov (United States)

    Biagioni, Rodrigo Bruno; Burihan, Marcelo Calil; Nasser, Felipe; Biagioni, Luisa Ciucci; Ingrund, José Carlos

    2018-02-01

    The endovascular management of arterial injuries has resulted in reduced operating time, blood loss, hospital mortality, lower incidence of sepsis, and decrease in mortality rates. For penetrating trauma, however, the benefits of endovascular therapy are questionable. Data were obtained by retrospective analysis of electronic medical records. All patients with vascular trauma seeking care at our institution from January 2010 to December 2015 were reviewed. A total of 223 vascular trauma patients were enrolled. Of these, 18 patients (8 %) were treated with endovascular techniques. The data related to clinical presentation, patient characteristics, technical aspects of the treatment, and follow-up were analysed. The mean patient age was 35.4 ± 17.8 years, 94 % were male. The mean injury severity score was 10.4 ± 2.5. The most commonly observed trauma mechanism was a gunshot in 10 cases (55 %), followed by lesions provoked by arterial catheter misplacement in five cases (27 %), and stab wounds in three cases (16.6 %). The main injury site was the subclavian artery, accounting for eight cases (44 %), followed by the superficial femoral artery and the tibiofibular trunk in two cases, respectively (18 %). The anterior tibial, fibular artery, axillary, common carotid, superior mesenteric, and profunda femoris were each affected once. Arteriovenous fistula was detected in nine cases (50 %), pseudoaneurysms in nine cases (50 %), and short occlusion in two cases (11 %). The mean follow-up duration was 753 days. The primary patency rate was 92.3 and 61.5 % after one and two years, respectively. The survival rate was 94.4 % after one and two years. Infection of the stents or limb amputations were not identified at follow-up. The endovascular treatment of penetrating arterial injuries with covered stents is feasible. However, the criteria used to choose the best method must be individualized.

  4. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    subclavian artery (LSA) limiting the proximal landing zone site without proximal vessel coverage. In patients in whom the distance between the LSA and aortic lesion is too short, extension of the landing zone can be obtained by covering the LSA's origin with the endovascular stent graft (ESG). This manoeuvre...

  5. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    Thoracic endovascular aortic repair (TEVAR) has emerged as a promising therapeutic alternative to conventional open aortic replacement but it requires suitable proximal and distal landing zones for stent-graft anchoring. Many aortic pathologies affect in the immediate proximity of the left subcla...

  6. Percutaneous endovascular stent-graft treatment of aortic aneurysms and dissections: new techniques and initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Choi, Dong Hoon; Kang, Sung Gwon; Lee, Kwang Hoon; Won, Jong Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of); Kang, Sung Gwon [Chosun University College of Medicine, Gwangju (Korea, Republic of); Won, Je Whan [Aju University College of Medicine, Suwon (Korea, Republic of); Song, Ho Young [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2003-01-01

    To evaluate the feasibility, safety and effectiveness of a newly designed percutaneously implanted separate stent-graft (SSG) for the treatment of aortic aneurysms and dissections. Using a percutaneous technique, SSG placement (in the descending thoracic aorta in 26 cases and infrarenal abdominal aorta in 24) was attempted in 50 patients with aortic aneurysms (n=27) or dissection (n=23). All SSGs were individually constructed using self-expandable nitinol stents and a Dacron graft, and were introduced through a 12 F sheath and expanded to a diameter of 20-34 mm. In all cases, vascular access was through the femoral artery. The clinical status of each patient was monitored, and postoperative CT was performed within one week of the procedure and at 3-6 month intervals afterwards. Endovascular stent-graft deployment was technically successful in 49 of 50 patients (98%). The one failure was due to torsion of the unsupported graft during deployment. Successful exclusion of aneurysms and the primary entry tears of dissections was achieved in all but three patients with aortic dissection. All patients in whom technical success was achieved showed complete thrombosis of the thoracic false lumen or aneurysmal sac, and the overall technique success rate was 92%. In addition, sixteen patients demonstrated complete resolution of the dissected thoracic false lumen (n=9) or aneurysmal sac (n=7). Immediate post-operative complications occurred at the femoral puncture site in one patient with an arteriovenous fistula, and in two, a new saccular aneurysm developed at the distal margin of the stent. No patients died, and there was no instance of paraplegia, stroke, side-branch occlusion or infection during the subsequent mean follow-up period of 9.4 (range, 2 to 26) months. In patients with aortic aneurysm and dissection, treatment with a separate percutaneously inserted stent-graft is technically feasible, safe, and effective.

  7. Endovascular repair of arterial iliac vessel wall lesions with a self-expandable nitinol stent graft system.

    Directory of Open Access Journals (Sweden)

    Birger Mensel

    Full Text Available To assess the therapeutic outcome after endovascular repair of iliac arterial lesions (IALs using a self-expandable Nitinol stent graft system.Between July 2006 and March 2013, 16 patients (13 males, mean age: 68 years with a self-expandable Nitinol stent graft. A total of 19 lesions were treated: nine true aneurysms, two anastomotic aneurysms, two dissections, one arteriovenous fistula, two type 1B endoleaks after endovascular aneurysm repair, one pseudoaneurysm, and two perforations after angioplasty. Pre-, intra-, and postinterventional imaging studies and the medical records were analyzed for technical and clinical success and postinterventional complications.The primary technical and clinical success rate was 81.3% (13/16 patients and 75.0% (12/16, respectively. Two patients had technical failure due to persistent type 1A endoleak and another patient due to acute stent graft thrombosis. One patient showed severe stent graft kinking on the first postinterventional day. In two patients, a second intervention was performed. The secondary technical and clinical success rate was 87.5% (14/16 and 93.8% (15/16. The minor complication rate was 6.3% (patient with painful hematoma at the access site. The major complication rate was 6.3% (patient with ipsilateral deep vein thrombosis. During median follow-up of 22.4 months, an infection of the aneurysm sac in one patient and a stent graft thrombosis in another patient were observed.Endovascular repair of various IALs with a self-expandable Nitinol stent graft is safe and effective.

  8. Pancreatitis-Associated Splenic Artery Pseudoaneurysm: Endovascular Treatment with Self-Expandable Stent-Grafts

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Vagenas, Kostantinos; Apostolopoulou, Sotiria C.; Panagiotou, Irene; Lymberopoulou, Dimitra; Kelekis, Dimitrios A.

    2003-01-01

    We present a patient with a splenic arterypseudoaneurysm (SAPA) treated with placement of self-expandable stent-grafts. The procedure was complicated by stent-graft migration,but successful management resulted in lasting exclusion of the SAPA,while the patency of the splenic artery was preserved. This is the first report of self-expandable stent-graft treatment of SAPA

  9. Potential Long-Term Complications of Endovascular Stent Grafting for Blunt Thoracic Aortic Injury

    Directory of Open Access Journals (Sweden)

    Larry E. Miller

    2012-01-01

    Full Text Available Blunt thoracic aortic injury (BTAI is a rare, but lethal, consequence of rapid deceleration events. Most victims of BTAI die at the scene of the accident. Of those who arrive to the hospital alive, expedient aortic intervention significantly improves survival. Thoracic endovascular aortic repair (TEVAR has been accepted as the standard of care for BTAI at many centers, primarily due to the convincing evidence of lower mortality and morbidity in comparison to open surgery. However, less attention has been given to potential long-term complications of TEVAR for BTAI. This paper focuses on these complications, which include progressive aortic expansion with aging, inadequate stent graft characteristics, device durability concerns, long-term radiation exposure concerns from follow-up computed tomography scans, and the potential for (Victims of Modern Imaging Technology VOMIT.

  10. Hybrid endovascular stent-grafting technique for patent ductus arteriosus in an adult.

    Science.gov (United States)

    Kainuma, S; Kuratani, T; Sawa, Y

    2011-09-01

    A 51-year-old man was referred to our institution for patent ductus arteriosus (PDA) complicated by left ventricular dysfunction and pulmonary hypertension. Surgical closure of a PDA is usually carried out via a small posterior thoracotomy. However, thoracoscopic procedures are probably not appropriate in adults because of the frequency of calcification and the greater risk of rupture while ligating the ductus. To minimize surgical trauma, we used hybrid endovascular stent grafting combined with revascularization of the left subclavian artery, which enabled us to eliminate shunt flow to the pulmonary artery. At 11-month follow-up, the patient was asymptomatic and showed no complications. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Ten-Year Follow-Up of Endovascular Aneurysm Treatment with Talent Stent-Grafts

    International Nuclear Information System (INIS)

    Pitton, Michael B.; Scheschkowski, Tobias; Ring, Markus; Herber, Sascha; Oberholzer, Katja; Leicher-Dueber, Annegret; Neufang, Achim; Schmiedt, Walther; Dueber, Christoph

    2009-01-01

    The purpose of this study was to evaluate the clinical results, complications, and secondary interventions during long-term follow-up after endovascular aneurysm repair (EVAR) and to investigate the impact of endoleak sizes on aneurysm shrinkage. From 1997 to March 2007, 127 patients (12 female, 115 male; age, 73.0 ± 7.2 years) with abdominal aortic aneurysms were treated with Talent stent-grafts. Follow-up included clinical visits, contrast-enhanced MDCT, and radiographs at 3, 6, and 12 months and then annually. Results were analyzed with respect to clinical outcome, secondary interventions, endoleak rate and management, and change in aneurysm size. There was no need for primary conversion surgery. Thirty-day mortality was 1.6% (two myocardial infarctions). Procedure-related morbidity was 2.4% (paraplegia, partial infarction of one kidney, and inguinal bleeding requiring surgery). Mean follow-up was 47.7 ± 34.2 months (range, 0-123 months). Thirty-nine patients died during follow-up; three of the deaths were related to aneurysm (aneurysm rupture due to endoleak, n = 1; secondary surgical reintervention n = 2). During follow-up, a total of 29 secondary procedures were performed in 19 patients, including 14 percutaneous procedures (10 patients) and 15 surgical procedures (12 patients), including 4 cases with late conversion to open aortic repair (stent-graft infection, n = 1; migration, endoleak, or endotension, n = 3). Overall mean survival was 84.5 ± 4.7 months. Mean survival and freedom from any event was 66.7 ± 4.5 months. MRI depicted significantly more endoleaks compared to MDCT (23.5% vs. 14.3%; P 10% of the aneurysm area were associated with reduced aneurysm shrinkage compared to no endoleaks or <10% endoleaks (Δ at 3 years, -1.8% vs. -12.0%; P < 0.05). In conclusion, endovascular aneurysm treatment with Talent stent-grafts demonstrated encouraging long-term results with moderate secondary intervention rates. Primary occlusion of all aortic side

  12. Endovascular Treatment of Dialysis Access-Induced Hand Ischemia Using a Flared Stent-Graft.

    Science.gov (United States)

    Png, Chien Yi M; Beckerman, William E; Faries, Peter L; Finlay, David J

    2017-10-01

    To report an investigation of a purely endovascular procedure to address access-induced hand ischemia in dialysis patients. Two dialysis patients presented with stage III steal syndrome consisting of severe pain and numbness in their fingers. Preoperative fistulograms distal to the anastomosis showed alternating antegrade and retrograde flow. Under ultrasound guidance, the fistula was accessed and a 4-F micropuncture sheath placed. An angled guidewire was then advanced proximally into the brachial artery. A 6-F short sheath with marker was placed followed by a 4-F straight guide catheter inserted into the proximal brachial artery. A 9-F Flair endovascular stent-graft was advanced over a 0.035-inch stiff angled Glidewire into the fistula just distal to the arterial anastomosis and deployed. Postoperatively, pain and numbness resolved in both patients immediately. Postoperative fistulograms documented antegrade flow. Access flow velocity readings decreased significantly and pulse oximetry readings increased significantly in both patients, who were followed for >6 months with no reported complications. These 2 cases suggest that this endovascular approach to access-induced hand ischemia may be a viable alternative to open/hybrid surgery.

  13. Endovascular treatment with a stent-graft for internal carotid artery laceration during trans sphenoidal surgery: a case report

    International Nuclear Information System (INIS)

    Choe, Eun Hwa; Ko, Ji Ho; Lee, Tae Hong; Rho, Myung Ho

    2008-01-01

    An internal carotid artery (ICA) tear during or after trans-sphenoidal surgery (TSS) is rare but may cause potentially lethal complications. A 23-year-old female patient visited our hospital for treatment of a Rathke's cleft cyst. The patient had massive hemorrhage during surgery and angiography performed after surgery showed laceration of the cavernous ICA. We successfully controlled the hemorrhage with emergency placement of an endovascular stent-graft

  14. One Year Outcomes of 101 BeGraft Stent Grafts used as Bridging Stents in Fenestrated Endovascular Repairs.

    Science.gov (United States)

    Spear, Rafaelle; Sobocinski, Jonathan; Hertault, Adrien; Delloye, Matthieu; Azzauiu, Richard; Fabre, Dominique; Haulon, Stéphan

    2018-04-01

    To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is

  15. Short-term curative effect of endovascular stent-graft treatment for aortic diseases in China: a systematic review.

    Directory of Open Access Journals (Sweden)

    Siwen Wang

    Full Text Available INTRODUCTION: We analyzed the short-term efficacy of endovascular treatment for aortic diseases by summarizing all available published data on endovascular stent-graft treatment for abdominal aortic aneurysm (AAA, thoracic aortic aneurysm (TAA, type A aortic dissection (type A AD and type B aortic dissection (type B AD in China. METHODS: We performed a systematic analysis of 935 published series on retrograde endovascular treatment for aortic diseases in China from January 1996 to November 2010. Based on the inclusion criteria, 159 studies, involving a total of 5531 patients, were included. RESULTS: There were no significant differences in procedural success among the studies (P>0.05. The rates of overall neurologic complications and stroke were significantly different in all two-group comparisons (P0.05. A significant difference was noted between the 30-day mortality rate of the type A AD patients and the AAA or type B AD patients (P<0.05. CONCLUSION: Endovascular stent-graft is a feasible and safe treatment for aortic diseases, with high procedural success and low incidences of post-procedural complications and short-term mortality. Endovascular treatment for AAA and type B AD is more efficient than for type A AD and TAA.

  16. Persistent Intraluminal Pressure After Endovascular Stent Grafting for Type B Aortic Dissection.

    Science.gov (United States)

    Qing, K-X; Chan, Y-C; Ting, A C W; Cheng, S W K

    2016-05-01

    Despite technically successful thoracic endovascular stent graft repair (TEVAR) in patients with Stanford Type B aortic dissection (TBAD), long-term follow up studies have shown that the false lumen may continue to dilate. The aim of this study was to analyze the possible mechanisms leading to such changes from a hemodynamic perspective. Twenty-eight ex vivo fresh porcine TBAD models (Mo A: 10; Model B: 12; Model C: 6) were established to simulate three clinical situations: Model A with patent false lumen (pre-TEVAR); Model B with distal re-entry only (post-TEVAR), and Model C with thrombus filling in the false lumen and a distal re-entry (chronic stage of post-TEVAR). Synchronous pressure waveforms were taken from both the true and the false lumen. True lumen and false lumen pressure differences were calculated for each model as four indices: systolic index (SI), diastolic index (DI), mean pressure index (MPI) and area under curve index (AUCI). These indices were compared between the three models. False lumen pressure and corresponding pressure-accumulating effects were significantly higher in Model A than in Model C: SI (99.9% vs. 189.4%; p area under curve (AUC) in Model C was merely lowered by 20% compared with its true lumen (67.5 mmHg vs. 85.2 mmHg). The false lumen pressure remained unchanged in the non-thrombosed segment with patent blood flow after the primary entry tear sealed. Intraluminal pressure reduction in the thrombosed false lumen was significant. However, nearly 80% of the pressure remained in the thrombosed false lumen. If this high intra-thrombus pressure persists, it may contribute to delayed aneurysmal formation after endovascular treatment. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  17. Clinical application of 64 multi-slice CT angiography for the follow-up of endovascular stent-graft exclusion

    International Nuclear Information System (INIS)

    Yin Longlin; Chen Jiayuan; Jiang Jin; Yang Zhigang; Li Zhenlin; Sun Jiayu; Zhu Hongmei

    2009-01-01

    Objective: To investigate the clinical applications of 64-MSCTA for the follow-up of endovascular stent-graft exclusion (EVE). Methods: Between Oct 2006 and Feb 2008, forty-four 64-MSCTA examinations were performed in 30 patients with aortic dissection (AD) and 5 patients with abdominal aortic aneurysm (AAA) who underwent EVE. Imaging reconstruction including MPR, MIP and VR were finished on workstation. The outcomes and complications after EVE of aortic dissection and aortic aneurysm were evaluated. Results: (1) Of 30 patients with aortic dissection, large thrombosis in false lumen was observed in 28 cases and small thrombosis in 2 cases. The cavity of aortic aneurysm outside the stent was thrombosed completely in 5 patients with AAA. (2) Thrombosis in the innominate artery on follow-up CTA after EVE was found in 1 AD patient with the innominate artery involved, Thrombosis in the superior mesenteric artery was observed on 15 days follow-up CTA but thrombolysis on 3 months after EVE in 1 case, Intimal tear in right common iliac artery was found in 1 case. Of 5 patients with AAA, occlusion of right inner iliac artery was observed in 1 case, and instent thrombosis in distal right common iliac artery was found in 1 case. (3) Endoleak was found in 14 patients with AD, including 8 with type I and 6 with type III endoleaks, one type III endoleak was disappeared on follow-up CTA after 3 months. Conclusions: 64-MSCTA with fast, non-invasive and effective merits, combining multiple reconstructive methods, has become one of preferred imaging methods in post-operative evaluation of EVE. (authors)

  18. Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

    International Nuclear Information System (INIS)

    Fanelli, Fabrizio; Cannavale, Alessandro; Gazzetti, Marianna; Fantozzi, Cristiano; Taurino, Maurizio; Speziale, Francesco

    2013-01-01

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient’s clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

  19. Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it; Cannavale, Alessandro [University of Rome ' Sapienza,' , Department of Radiological Sciences, Vascular and Interventional Radiology Unit (Italy); Gazzetti, Marianna [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy); Fantozzi, Cristiano; Taurino, Maurizio [University of Rome ' Sapienza,' , Department of Vascular Surgery (Italy); Speziale, Francesco [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy)

    2013-02-15

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient's clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

  20. Endovascular Aortic Aneurysm Repair with the Talent Stent-Graft: Outcomes in Patients with Large Iliac Arteries

    International Nuclear Information System (INIS)

    England, Andrew; Butterfield, John S.; McCollum, Charles N.; Ashleigh, Raymond J.

    2008-01-01

    The purpose of this study is to report outcomes following endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) in patients with ectatic common iliac arteries (CIAs). Of 117 AAA patients treated by EVAR between 1998 and 2005, 87 (74%) had CIAs diameters 18 but <25 mm. All patients were treated with Talent stent-grafts, 114 bifurcated and 3 AUI devices. Departmental databases and patient records were reviewed to assess outcomes. Technical success, iliac-related outcome, and iliac-related reintervention (IRSI) were analyzed. Patients with EVAR extending into the external iliac artery were excluded. Median (range) follow-up for the study group was 24 (1-84) months. Initial technical success was 98% for CIAs <18 mm and 100% for CIAs ≥18 mm (p = 0.551). There were three distal type I endoleaks (two in the ectatic group) and six iliac limb occlusions (one in an ectatic patient); there were no statistically significant differences between groups (p = 0.4). There were nine IRSIs (three stent-graft extensions, six femorofemoral crossover grafts); three of these patients had one or both CIAs ≥18 mm (p = 0.232). One-year freedom from IRSI was 92% ± 3% and 84% ± 9% for the <18-mm and ≥18-mm CIA groups, respectively (p = 0.232). We conclude that the treatment of AAA by EVAR in patients with CIAs 18-24 mm appears to be safe and effective, however, it may be associated with more frequent reinterventions.

  1. Outcomes of Endovascular Aneurysm Repair using the Ovation Stent Graft System in Adverse Anatomy.

    Science.gov (United States)

    Greaves, Nicholas S; Moore, Aiden; Seriki, Dare; Ghosh, Jonathan

    2018-04-01

    The aim was the evaluation of mid-term efficacy and safety outcome measures for the Ovation (Endologix, Santa Rosa, CA, USA) stent graft system in the management of infrarenal abdominal aortic aneurysms (iAAA) with adverse anatomy. A retrospective observational study of all patients undergoing elective iAAA repair was carried out from 2012 to 2017 using Ovation Prime or iX stent grafts with a minimum of 3 months follow-up at a single UK vascular centre. Post-operative surveillance involved computed tomography scans at 3 months and 1 year, with duplex ultrasound yearly thereafter. Outcome measures were established with retrospective analysis of pre- and post-operative imaging, and included peri-operative mortality, major adverse events, limb complications, aneurysm diameter change, and endoleak rates. All patients were within Ovation instructions for use (IFU), and assessment was made to determine whether aneurysms had anatomical features considered adverse for other commonly used stent graft platforms. Ovation stent grafts were implanted in 52 patients (79% male, mean age 75.7 years) with a mean aneurysm diameter of 62.5 mm (range 55-107 mm). There was 100% technical deployment success. The 30 day mortality was 0% and there was no aneurysm related mortality during follow-up (median 24 months, range 3-48 months). There were no type I or III endoleaks, but 19% developed type II endoleaks with one patient requiring re-intervention. No iliac limb occlusions were identified but one case required relining for limb kinking. All 52 cases were within the IFU for Ovation but only 12% met the IFU criteria for the Cook and Medtronic devices. The mid-term experience with Ovation demonstrates safe, durable treatment of iAAAs, including those with unfavourable anatomy, frequently off IFU for other commonly used devices. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  2. Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones

    Directory of Open Access Journals (Sweden)

    Ying Guan

    2016-08-01

    Full Text Available Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU and polyester graft (nitinol-PET materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.

  3. Endovascular stent-graft placement for the treatment of acute onset and chronic aortic dissections of the descending aorta (Short-term follow-up)

    International Nuclear Information System (INIS)

    Petrov, I; Jorgova, J.; Trendafilova, D.

    2004-01-01

    The leading cause of death for patients with surgically untreated thoracic aortic aneurysms is the rupture of the aneurysm. Almost one half of these patients are left to medical treatment assuming the risk of late rupture and aneurysm sac enlargement - the late surgical treatment of these patients is too risky and with poor results. On the other hand the emergent surgical treatment of these cases is related with relatively high mortality rate. Recently, thoracic aortic stent-grafting has emerged as a less traumatic alternative therapeutic modality for patients with thoracic aortic aneurysms and aortic dissections. The first case of stent implantation in a dissected descending aorta was performed in Bulgaria at 09.04.2003. Since then we implanted in 8 patients thoracic stent grafts, The mean age of the patients was 67.5 years. The primary success was 100%. One died on the second postoperative day by abdominal aorta rupture. No other complications were registered. The mean follow-up of 5 months proved to be uneventful and the control CT revealed efficacious sealing of the entry and false lumen thrombosis in all except one cases. We report our initial clinical experience of endovascular stent-graft repair for dissection of the descending aorta that is encouraging. These preliminary data suggest that endovascular stent-grafting is a viable treatment for acute onset and chronic aortic dissection type B

  4. Endovascular Treatment of a Giant Superior Mesenteric Artery Pseudoaneurysm Using a Nitinol Stent-Graft

    International Nuclear Information System (INIS)

    Gandini, Roberto; Pipitone, Vincenzo; Konda, Daniel; Pendenza, Gianluca; Spinelli, Alessio; Stefanini, Matteo; Simonetti, Giovanni

    2005-01-01

    A 68-year-old woman presenting with gastrointestinal bleeding (hematocrit 19.3%) and in a critical clinical condition (American Society of Anesthesiologists grade 4) from a giant superior mesenteric artery pseudoaneurysm (196.0 x 131.4 mm) underwent emergency endovascular treatment. The arterial tear supplying the pseudoaneurysm was excluded using a 5.0 mm diameter and 31 mm long monorail expanded polytetrafluoroethylene (ePTFE)-covered self-expanding nitinol stent. Within 6 days of the procedure, a gradual increase in hemoglobin levels and a prompt improvement in the clinical condition were observed. Multislice CT angiograms performed immediately, 5 days, 30 days and 3 months after the procedure confirmed the complete exclusion of the pseudoaneurysm

  5. The INNOVATION Trial: four-year safety and effectiveness of the INCRAFT® AAA Stent-Graft System for endovascular repair.

    Science.gov (United States)

    Pratesi, Giovanni; Pratesi, Carlo; Chiesa, Roberto; Coppi, Gioacchino; Scheinert, Dierk; Brunkwall, Jan S; van der Meulen, Stefaan; Torsello, Giovanni

    2017-10-01

    This paper reports the 4-year safety and effectiveness of the INCRAFT® AAA Stent-Graft System (Cordis Corp., Milpitas, CA, USA), an ultra-low-profile device for the treatment of abdominal aortic aneurysms. The INNOVATION Trial is the prospective, first-in-human, multicenter trial to evaluate the safety and effectiveness of the INCRAFT® System. Patients underwent annual clinical and computed tomography angiography examination as part of the study protocol. The INCRAFT® AAA Stent-Graft System is a customizable tri-modular design, with an ultra-low profile (14-Fr) delivery system. Patient were treated under approved protocol, the prescribed clinical and imaging follow-up at annually through 5 years. Results analyzed and adjudicated by a clinical events committee, independent core laboratory, and a data safety and monitoring board. This manuscript reports results through 4 years of follow-up. A total of 60 patients were enrolled in the trial, all of whom were successfully treated. Follow-up rates at 1 and 4 years were 93% (56/60) and 85% (51/60), respectively. All-cause mortality at 4 years was 17.6% and no death was AAA-, device-, or procedure-related. The secondary reintervention rate at 1 year was 4.6%, primarily the result of stent thrombosis. In total, 10 patients required 13 post-procedure interventions within 4-years of follow-up (2 to repair a type I endoleak, 4 to repair a type II endoleak, 1 for stent thrombosis, 1 for renal stenosis, 1 for aneurysm enlargement, 2 for limb migration and 2 for prosthesis stenosis or occlusion). There were 4 cases (10%) of aneurysm enlargement reported at the 4 year follow-up. At 4 years, 38 out of 39 patients were free from type I and III endoleaks. There were no proximal type I or type III endoleaks at 4-year follow-up. Core laboratory evaluation of the postoperative imaging studies indicated absence of endograft migration while a single fracture was demonstrated without any clinical sequelae. The INCRAFT® AAA Stent-Graft

  6. Stent fractures in the Hemobahn/Viabahn stent graft after endovascular popliteal aneurysm repair

    NARCIS (Netherlands)

    Tielliu, Ignace F. J.; Zeebregts, Clark J.; Vourliotakis, George; Bekkema, Foppe; van den Dungen, Jan J. A. M.; Prins, Ted R.; Verhoeven, Eric L. G.

    Objective: During the last decade, endovascular repair of popliteal artery aneurysms (PAAs) has become a valid alternative to open repair. This study analyzes the incidence and origin of stein graft fractures after endovascular repair, its impact on patency, and strategies to prevent fractures.

  7. Management of Endovascular Aortic Aneurysm Complications via Retrograde Catheterization Through the Distal Stent-Graft Landing Zone.

    Science.gov (United States)

    Zhang, Xicheng; Sun, Yuan; Chen, Zhaolei; Jing, Yuanhu; Xu, Miao

    2017-08-01

    A retrograde technique through the gap between the distal stent landing zone and the iliac artery wall has been applied to treat type II endoleak after endovascular aortic aneurysm repair (EVAR). In this study, we tried to investigate its efficacy in the management of type III endoleak and intraoperative accidental events. We reported 2 complications of EVAR that were difficult to treat with conventional methods. One patient had a sustained type III endoleak after EVAR, and the right renal artery was accidentally sealed by a graft stent in the other patient during the operation. Both complications were managed by the retrograde technique from the distal stent landing zone. In the first case, the endoleak was easily embolized by the retrograde catheterization technique, and in the second case, a stent was implanted in the right renal artery using the retrograde technique to restore blood flow. In some EVAR cases, the technique of retrograde catheterization through the distal stent-graft landing zone is feasible, safe, and easy to perform.

  8. Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms.

    Science.gov (United States)

    Pineda, Danielle M; Troutman, Douglas A; Dougherty, Matthew J; Calligaro, Keith D

    2016-05-01

    Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion. Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries. We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication. Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms. © The Author(s) 2016.

  9. MRI assessment of thoracic stent grafts after emergency implantation in multi trauma patients: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Rasche, Volker [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); University Hospital Ulm, University of Ulm, Department of Internal Medicine II, Ulm (Germany); Oberhuber, Alexander; Orend, Karl-Heinz [University Hospital Ulm, Department of Vascular and Thoracic Surgery, Ulm (Germany); Trumpp, Stephan [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); University Hospital Ulm, Department of Vascular and Thoracic Surgery, Ulm (Germany); Bornstedt, Axel; Merkle, Nico; Rottbauer, Wolfgang [University Hospital Ulm, Department of Internal Medicine II, Ulm (Germany); Hoffmann, Martin [University Hospital Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany)

    2011-07-15

    To evaluate the feasibility of MRI for static and dynamic assessment of the deployment of thoracic aortic stent grafts after emergency implantation in trauma patients. Twenty patients initially presenting with a rupture of the thoracic aorta were enrolled in this study. All patients underwent thoracic endovascular aortic repair (TEVAR). The deployment of the implanted stent graft was assessed by CTA and MRI, comprising the assessment of the aortic arch with and without contrast agent, and the assessment of the motion of the stent graft over the cardiac cycle. The stent graft geometry and motion over the cardiac cycle were assessable by MRI in all patients. Flow-mediated signal variations in areas of flow acceleration could be well visualised. No statistically significant differences in stent-graft diameters were observed between CT and MRI measurements. MRI appears to be a valuable tool for the assessment of thoracic stent grafts. It shows similar performance in the accurate assessment of stent-graft dimensions to the current gold standard CTA. Its capability of providing additional functional information and the lack of ionising radiation and nephrotoxic contrast agents may make MRI a valuable tool for monitoring patients after TEVAR. (orig.)

  10. Endovascular stent-graft exclusion of aortic dissection combined with renal failure

    International Nuclear Information System (INIS)

    Feng Xiang; Jing Zaiping; Yuan Weijie; Bao Junmin; Zhao Zhiqing; Zhao Jun; Lu Qingsheng

    2003-01-01

    Objective: To investigate the indications and peri-operative management of endovascular graft exclusion of aortic dissection combined with renal failure. Methods: Endovascular graft exclusion for Stanford B type thoracic aortic dissection had been preformed on 136 patients including two complicated with renal failure. Hemodialysis was preformed before operation with the fluid infusion controlled during the operation and bed-side hemodialysis after the operation for the latter. Results: All the 2 cases with renal failure complication were successfully carried out, and the peri-operative metabolism and circulation were kept on smoothly. Conclusions: Under good peri-operative management, patients having aortic dissection combined with renal failure could receive the endovascular graft exclusion of aortic dissection safely

  11. Retrograde type A dissection: a serious complication due to thoracic aortic endovascular stent-graft repair for Stanford type B aortic dissection

    International Nuclear Information System (INIS)

    Wang Guoquan; Zhai Shuiting; Li Tianxiao; Shi Shuaitao; Zhang Kewei; Li Kun

    2011-01-01

    Objective: to discuss the possible causes and prevention of retrograde type A dissection occurred after thoracic aortic endovascular stent-graft repair (TEVAR) for symptomatic type B dissection. Methods: During the period from January 2005 to January 2011, TEVAR was carried out in 189 patients (157 males and 32 females) with symptomatic type B dissection. The average age of the patients was (51.2±13.5) years, ranged from 26 to 78 years. A follow-up lasting for 3-63 months (mean 32 months) was conducted in 135 patients (71.43%). Fifty-four patients lost in touch with the authors (28.57%). The occurrence of retrograde type A dissection after TEVAR was calculated and the possible causes were analyzed. Results: After TEVAR retrograde type A dissection occurred in two patients (1.48%), and both were males. One patient developed retrograde type A dissection in perioperative period, and the patient refused to have surgery. Conservative treatment was employed for over three years and be was still alive so far. The other patient developed retrograde type A dissection one month after TEVAR, and emergency surgery was performed. The patient was followed up for three months and he was still alive. Conclusion: The retrograde type A dissection occurred after TEVAR may be closely related to the stent-graft device, to the interventional manipulations and to the vascular disorders. Close attention should be paid to the direct damage produced by the stent-graft device to the vascular wall. (authors)

  12. Endovascular repair of posttraumatic multiple femoral-femoral and popliteal-popliteal arteriovenous fistula with Viabahn and excluder stent graft

    Directory of Open Access Journals (Sweden)

    Šarac Momir

    2011-01-01

    . Also, numerous metallic balls - grains of shotgun were present. After the preoperative preparation under local infiltrative anesthesia, transfemoral endovascular reconstruction was done of the surface femoral and popliteal artery by the use of stent grafts Viabahn 6 × 50 mm and excluder PXL 161 007. Within the immediate postoperative course a significant reduction of the leg edema and disappearance of thrill occurred, and, latter, healing of ulceration, and disappearance of signs of the foot ischemia. Also, patient's both cardiac and breathing functions became normal. Conclusion. In patients with chronic traumatic AV fistulas in the femoropopliteal region, especially with multiple fistulas, the gold standard is their endovascular reconstruction which, although being minimally traumatic and invasive, offers a complete reconstruction besides keeping integrity of both distal and proximal circulation in the leg.

  13. Stent Graft in Managing Juxta-Renal Aortoiliac Occlusion

    International Nuclear Information System (INIS)

    Prabhudesai, V.; Mitra, K.; West, D. J.; Dean, M. R. E.

    2003-01-01

    Endovascular procedures are frequently used as an alternative to surgical bypass in aortic and iliac occlusion. Stents have revolutionized the scope of such endovascular procedures, but there are few reports of stents or stent grafts in occlusive juxta-renal aortic occlusion. We present a case where such occlusion was managed by use of a stent graft with successful outcome

  14. Midterm results of endovascular stent graft treatment for descending aortic aneurysms including high-risk patients

    Directory of Open Access Journals (Sweden)

    Gussmann, Andreas

    2006-04-01

    Full Text Available Methods: 21 patients (17 men, 4 women; mean age 66.1 years, range 29-90 years with 15 true aneurysms, and 6 type B-dissections were treated by implantation of a TalentTM Endoluminal Stentgraft System from February 2000 to July 2003. In 3 cases it was necessary to overstent the left subclavian artery, in 1 case to overstent the left common carotid. Results: 2 patients (9.5% died during the first 30 days (1 myocardial infarction, 1 pneumonia. Two patients (9.5% suffered from cerebral ischemia and needed revascularisation. No paraplegia, no stroke occurred. One endoleak required additional stenting. No patient needed conversion. Follow-up, average 25.4 months (range 0-39, was 100% complete. During this another two patients died of myocardial infarction i.e. 9.5% (the above mentioned endoleak, but no late migration were detected in the remaining patients. In all cases the graft lumen stayed patent. Conclusions: Treatment of descending thoracic aortic aneurysm with an endovascular approach has acceptable mortality and morbidity-rates even in high risk patients. Procedural overstenting of the subclavian artery requires subclavian revascularisation in a minority of cases.

  15. Endovascular abdominal aortic repair for AAA. Anatomical suitability and limitation in Japanese population according to the inclusion criteria of Zenith AAA stent graft

    International Nuclear Information System (INIS)

    Kitagawa, Atsushi; Okita, Yutaka; Okada, Kenji

    2009-01-01

    Since 2007, the EVAR (endovascular abdominal aortic repair) grafts, Zenith, Excluder and Powerlink had been commercially available in Japan. However, a small iliac artery, typical of Japanese population especially in women, was a limiting factor to indicate EVAR. We analyzed the suitability of EVAR in Japanese population according to the inclusion criteria of Zenith AAA stent graft in the current study. From January 2006 to December 2007, 106 AAA (abdominal aortic aneurysm) patients (88 men, 18 women) with a mean age of 73 years were investigated in our institution by multi-slice CT scan in terms of suitability of EVAR, then we measured their abdominal aorta and iliac artery parameters as follows; proximal neck diameter (PND) and length (PNL), common iliac artery diameter (CIAD) and length (CIAL), suprarenal (SNA) and infrarenal neck angulation (INA), external iliac artery diameter (EIAD) and aortic length from the lowest renal artery to the aortic bifurcation (AOL). The inclusion criteria for Zenith AAA stent graft treatment were; PND: 18-28 mm, PNL more than 15 mm, unilateral CIAD less than 20 mm, CIAL at least 10 mm, SNA less than 45 degree and INA less than 60 degree, unilateral EIAD more than 7.5 mm. The indication of EVAR was 25.5% (27/106 patients), and was especially very low in women (5.6%) strictly according to the inclusion criteria of the Zenith AAA stent graft. The main reason of exclusion of EVAR was proximal short neck (40.5%), small iliac artery (30.4%) and infrarenal aortic neck angulation (29.1%). In our analysis, female AAA patients had small PNL and EIAD with angulated neck compared with male AAA ones. Anatomical suitability of EVAR in Japanese population strictly following by the inclusion criteria of Zenith AAA stent graft was low due to their characteristic differences from the European Union (EU) and the United States (US) patients, such as short proximal neck, steep neck angulation and small iliac artery, especially in women. More flexible

  16. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  17. Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft.

    LENUS (Irish Health Repository)

    Molony, David S

    2009-01-01

    BACKGROUND: Abdominal aortic aneurysms (AAA) are local dilatations of the infrarenal aorta. If left untreated they may rupture and lead to death. One form of treatment is the minimally invasive insertion of a stent-graft into the aneurysm. Despite this effective treatment aneurysms may occasionally continue to expand and this may eventually result in post-operative rupture of the aneurysm. Fluid-structure interaction (FSI) is a particularly useful tool for investigating aneurysm biomechanics as both the wall stresses and fluid forces can be examined. METHODS: Pre-op, Post-op and Follow-up models were reconstructed from CT scans of a single patient and FSI simulations were performed on each model. The FSI approach involved coupling Abaqus and Fluent via a third-party software - MpCCI. Aneurysm wall stress and compliance were investigated as well as the drag force acting on the stent-graft. RESULTS: Aneurysm wall stress was reduced from 0.38 MPa before surgery to a value of 0.03 MPa after insertion of the stent-graft. Higher stresses were seen in the aneurysm neck and iliac legs post-operatively. The compliance of the aneurysm was also reduced post-operatively. The peak Post-op axial drag force was found to be 4.85 N. This increased to 6.37 N in the Follow-up model. CONCLUSION: In a patient-specific case peak aneurysm wall stress was reduced by 92%. Such a reduction in aneurysm wall stress may lead to shrinkage of the aneurysm over time. Hence, post-operative stress patterns may help in determining the likelihood of aneurysm shrinkage post EVAR. Post-operative remodelling of the aneurysm may lead to increased drag forces.

  18. Spinal arterial anatomy and risk factors for lower extremity weakness following endovascular thoracoabdominal aortic aneurysm repair with branched stent-grafts.

    Science.gov (United States)

    Chang, Catherine K; Chuter, Timothy A M; Reilly, Linda M; Ota, Maile K; Furtado, Andre; Bucci, Monica; Wintermark, Max; Hiramoto, Jade S

    2008-06-01

    To evaluate spinal arterial anatomy and identify risk factors for lower extremity weakness (LEW) following endovascular thoracoabdominal aortic aneurysm (TAAA) repair. A retrospective review was conducted of 37 patients (27 men; mean age 74.8+/-7.1 years, range 58-86) undergoing endovascular TAAA repair with branched stent-grafts at a single academic institution from July 2005 to December 2007. Data were collected on preoperative comorbidities, duration of operation, blood loss, type of anesthesia, extent of aortic coverage, blood pressure, cerebrospinal fluid (CSF) pressure and drainage, and postoperative development of LEW. Pre- and postoperative contrast-enhanced computed tomographic angiograms (CTA) in a 26-patient subset were analyzed to evaluate the number of patent intercostal and lumbar arteries before and after repair. All patients were neurologically intact at the end of the operation. Seven (19%) patients developed LEW postoperatively: 6 perioperatively and 1 after discharge. LEW was associated with postoperative hypotension, internal iliac artery (IIA) occlusion, and fewer patent segmental arteries on preoperative CTA. Lowest mean systolic blood pressure was segmental arteries in patients with or without LEW. Endovascular TAAA repair inevitably occludes direct inflow to lumbar and intercostal arteries. The distal segments of these arteries to the spine, however, are seen to remain patent through collaterals. Measures to preserve collateral pathways and increase perfusion pressure may help prevent or treat LEW.

  19. Exclusion of Atherosclerotic Plaque from the Circulation Using Stent-Grafts: Alternative to Carotid Stenting with a Protection Device?

    International Nuclear Information System (INIS)

    Peynircioglu, Bora; Geyik, Serdar; Yavuz, Kivilcim; Cil, Barbaros E.; Saatci, Isil; Cekirge, Saruhan

    2007-01-01

    Purpose. To retrospectively assess the feasibility, safety, and clinical mid-term outcome of patients undergoing carotid artery stenting with stent-grafts. Methods. Over a 4 year period stent-grafts were used in the endovascular treatment of symptomatic internal carotid artery stenosis in 12 patients (2 women, 10 men, aged 47-83 (mean 64) years). Protection devices were not used. Possible microembolic complications were evaluated by magnetic resonance imaging (MRI) examinations of the brain before and the day after the procedure in all patients. Mean follow-up was 22 months (range 1-42 months), by Doppler ultrasonography and conventional angiography as well as clinical examination .Results. The technical success rate was 100%. A total of 13 coronary stent-grafts were used. The mean stenosis rate (in terms of diameter) was 85% and the mean length of stent-grafts used was 20.9 mm. The mean diameter to which the stent-grafts were dilated was 4.66 mm. In-hospital complications occurred in 1 patient who suffered a minor femoral access hematoma that did not require transfusion or surgical decompression. Post-stenting diffusion-weighted MRI revealed several ipsilateral silent microemboli in only 1 case, which was completely asymptomatic. Two patients had a major stroke after 2 years of follow-up. Restenosis was found in 2 patients who underwent successful balloon dilatation followed by placement of a self-expandable bare stent within the stent-grafts. Conclusions. Stent-grafts may prevent microembolic complications during stenting of atherosclerotic carotid lesions in selected cases, offering immediate exclusion of the atherosclerotic lesion from the circulation by pressing the plaque against the vessel wall. Comparative, randomized studies in larger series of patients are needed with carotid-dedicated stent-graft designs

  20. Automatic segmentation of the wire frame of stent grafts from CT data.

    NARCIS (Netherlands)

    Klein, A.; Vliet, J.A. van der; Oostveen, L.J.; Hoogeveen, Y.L.; Schultze Kool, L.J.; Renema, W.K.J.; Slump, C.H.

    2012-01-01

    Endovascular aortic replacement (EVAR) is an established technique, which uses stent grafts to treat aortic aneurysms in patients at risk of aneurysm rupture. Late stent graft failure is a serious complication in endovascular repair of aortic aneurysms. Better understanding of the motion

  1. Resolved Abdominal Aortic Aneurysms Following Stent Graft Treatment: A Report of Five Cases

    International Nuclear Information System (INIS)

    Rimon, Uri; Garniek, Alexander; Golan, Gil; Bensaid, Paul; Galili, Yair; Schneiderman, Jacob; Morag, Benyamina

    2004-01-01

    Complete aneurysm resolution is the hallmark of successful endoluminal stent-graft treatment. We describe 5 patients in whom an abdominal aortic aneurysm (AAA) disappeared completely at mid-term follow-up after endovascular stent-graft placement. We reviewed 45 patients (43 men and 2 women) who underwent AAA repair using an endovascular technique, from April 1997 to December 2001. Mean AAA diameter was 58.3 mm. On 48-month follow-up, 12 aneurysms had not changed in size, 4 had grown, 16 had shrunk, and 5 had resolved completely. We describe these 5 patients in detail. The 5 patients were all men, mean age 68 years; their mean aneurysmal sac diameter was 54 mm. The only common finding in all of them was patency of lumbar and inferior mesenteric arteries at pre-procedure evaluation as well as at follow-up. Mean time to complete resolution was 18 months. No major complications were encountered. AAA may resolve completely after endovascular stent-graft implantation. Patent side branches may perhaps contribute to AAA disappearance by antegrade flow. A larger patient population should be reviewed, however, before any statistical conclusion can be drawn

  2. Shear accumulation as a means for evaluating risk of thromboembolic events in novel endovascular stent graft designs.

    Science.gov (United States)

    Suess, Taylor; Anderson, Joseph; Sherman, Andrea; Remund, Tyler; Pohlson, Kathryn; Mani, Gopinath; Gent, Stephen; Kelly, Patrick

    2017-06-01

    This study proposes to establish a simulation-based technique for evaluating shear accumulation in stent grafts and to use the technique to assess the performance of a novel branched stent graft system. Computational fluid dynamics models, with transient boundary conditions, particle injection, and rigid walls, simplifying assumptions were developed and used to evaluate the shear accumulation in various stent graft configurations with a healthy aorta as comparison. Shear streamlines are presented for the various configurations. Shear accumulation was also calculated for each configuration. The number of particles with shear accumulations >3.5 Pa-s for each configuration was compared with the shear accumulation values of commercially available mechanical aortic valves from the literature. The stent graft configuration with the diaphragm does have particles with shear accumulation >3.5 Pa-s. However, the percentage of particles with shear accumulation above 3.5 Pa-s is less than the two commercially available mechanical aortic valves, and more surprisingly, is smaller than in the healthy aorta. Copyright © 2016. Published by Elsevier Inc.

  3. Delayed Development of Brain Abscesses Following Stent-Graft Placement in a Head and Neck Cancer Patient Presenting with Carotid Blowout Syndrome

    International Nuclear Information System (INIS)

    Oweis, Yaseen; Gemmete, Joseph J.; Chaudhary, Neeraj; Pandey, Aditya; Ansari, Sameer

    2011-01-01

    We describe the delayed development of intracranial abscesses following emergent treatment with a covered stent-graft for carotid blowout syndrome (CBS) in a patient with head and neck cancer. The patient presented with hemoptysis and frank arterial bleeding through the tracheostomy site. A self-expandable stent-graft was deployed across a small pseudoaneurysm arising from the right common carotid artery (RCCA) and resulted in immediate hemostasis. Three months later, the patient suffered a recurrent hemorrhage. CT of the neck demonstrated periluminal fluid around the caudal aspect of the stent-graft with intraluminal thrombus and a small pseudoaneurysm. Subsequently, the patient underwent a balloon test occlusion study and endovascular sacrifice of the RCCA and right internal carotid artery. MRI of the brain demonstrated at least four ring-enhancing lesions within the right cerebral hemisphere consistent with intracranial abscesses that resolved with broad-spectrum antibiotic coverage.

  4. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology (Korea, Republic of); Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C. [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States); Kern, John A.; Cherry, Kenneth J. [University of Virginia Health System, Department of Surgery (United States); Matsumoto, Alan H., E-mail: ahm4d@virginia.edu [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States)

    2012-12-15

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 {+-} 5.6 mm; range 1.5-25.0 mm) and diameter (mean, 13.5 {+-} 9.7 mm; range 2.2-41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  5. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C.; Kern, John A.; Cherry, Kenneth J.; Matsumoto, Alan H.

    2012-01-01

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 ± 5.6 mm; range 1.5–25.0 mm) and diameter (mean, 13.5 ± 9.7 mm; range 2.2–41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  6. Tube Stent-Grafts for Infrarenal Aortic Aneurysm: A Matched-Paired Analysis Based on EUROSTAR Data

    International Nuclear Information System (INIS)

    Ruppert, Volker; Leurs, Lina J.; Hobo, Roel; Buth, Jacob; Rieger, Johannes; Umscheid, Thomas

    2007-01-01

    Objective. Tube stent-grafts for treatment of infrarenal aortic aneurysms (AAAs) are a nearly forgotten concept. For focal aortic pathologies tube stent-grafts may be a treatment option. We have performed a retrospective matched-paired analysis of the EUROSTAR registry regarding the outcome of tube vs. bifurcated stent-grafts for AAA. Tapered aortomonoiliac stent-grafts were not the objective of this study. Materials and methods. From July 1997 to June 2006, 7581 patients who underwent an endovascular AAA repair were entered in the EUROSTAR registry by 164 centers. One hundred fifty-three patients were treated with tube stent-grafts. For each of these 153 patients we selected one patient from a bifurcated stent-graft group (BGG-original, 7428 patients) matched according to gender, ASA, age, AAA diameter, and type of anesthesia. Differences in preoperative details between the two study groups were analyzed using chi-square test for discrete variables and Wilcoxon rank-sum test for continuous variables. Multivariate logistic regression analysis was performed on early complications. Midterm outcomes (>30 days) were analyzed by Kaplan-Meier and multivariate Cox proportional hazard model. Results. The duration of the procedure was shorter in the tube stent-graft group (TGG; 102.3 ± 52.2) than in BGG (128.3 ± 55.0; p 0.0002). Type II endoleak was less frequent in TGG (4.0%; mean follow-up, 23.12 ± 23.9 months) than in BGG (14.3%; mean follow-up, 20.77 ± 20.0 months; p = 0.0394). Type I endoleaks and migration were distributed equally, without significant differences between the groups. Combined 30-day and late mortality was higher for TGG (p = 0.0346) and was obviously not aneurysm related. Conclusions. We conclude that after selection of patients, tube stent-grafts for infrarenal aortic repair can be performed with great safety regarding endoleaks and migration. The combined higher 30-day mortality and non-aneurysm-related mortality during follow-up were mainly

  7. Thoracic Stent Graft Implantation for Aortic Coarctation with Patent Ductus Arteriosus via Retroperitoneal Iliac Approach in the Presence of Small Sized Femoral Artery

    Directory of Open Access Journals (Sweden)

    Ozge Korkmaz

    2016-01-01

    Full Text Available Endovascular stent graft implantation is a favorable method for complex aortic coarctation accompanied by patent ductus arteriosus. Herein, an 18-year-old woman with complex aortic coarctation and patent ductus arteriosus was successfully treated by endovascular thoracic stent graft via retroperitoneal approach. The reason for retroperitoneal iliac approach was small sized common femoral arteries which were not suitable for stent graft passage. This case is the first aortic coarctation plus patent ductus arteriosus case described in the literature which is treated by endovascular thoracic stent graft via retroperitoneal approach.

  8. Hepatic artery stent-grafts for the emergency treatment of acute bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Bellemann, Nadine, E-mail: nadine.bellemann@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Sommer, Christof-Matthias; Mokry, Theresa; Kortes, Nikolas; Gnutzmann, Daniel; Gockner, Theresa; Schmitz, Anne [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Weitz, Jürgen [Department of Surgery, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Department for Visceral, Thoracic and Vascular Surgery at the University Hospital, Technical University Dresden (Germany); Kauczor, Hans-Ulrich; Radeleff, Boris; Stampfl, Ulrike [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany)

    2014-10-15

    Highlights: • We report our experiences with stent-grafts for the treatment of acute hemorrhage from the hepatic artery or the stump of the gastroduodenal artery. • The technical success of stent-graft implantation was 88%. • The bleeding ceased immediately after stent-graft implantation in 88%. • The complication rate was 21%. - Abstract: Purpose: We evaluated the technical success and clinical efficacy of stent-graft implantation for the emergency management of acute hepatic artery bleeding. Methods: Between January 2010 and July 2013, 24 patients with hemorrhage from the hepatic artery were scheduled for emergency implantation of balloon expandable stent-grafts. The primary study endpoints were technical and clinical success, which were defined as successful stent-graft implantation with sealing of the bleeding site at the end of the procedure, and cessation of clinical signs of hemorrhage. The secondary study endpoints were complications during the procedure or at follow-up and 30-day mortality rate. Results: In 23 patients, hemorrhage occurred after surgery, and in one patient hemorrhage occurred after trauma. Eight patients had sentinel bleeding. In most patients (n = 16), one stent-graft was implanted. In six patients, two overlapping stent-grafts were implanted. The stent-grafts had a target diameter between 4 mm and 7 mm. Overall technical success was 88%. The bleeding ceased after stent-graft implantation in 21 patients (88%). The mean follow-up was 137 ± 383 days. In two patients, re-bleeding from the hepatic artery occurred during follow-up after 4 and 29 days, respectively, which could be successfully treated by endovascular therapy. The complication rate was 21% (minor complication rate 4%, major complication rate 17%). The 30-day mortality rate was 21%. Conclusions: Implantation of stent-grafts in the hepatic artery is an effective emergency therapy and has a good technical success rate for patients with acute arterial hemorrhage.

  9. Assessment of Competence in EVAR Stent Graft Sizing and Selection

    DEFF Research Database (Denmark)

    Strøm, M; Lönn, L.; Bech, B.

    2017-01-01

    Objectives and background: The aims of this study were to develop a test of competence in endovascular aortic repair (EVAR) stent graft sizing and selection; to examine the test for evidence of validity; and to explore the experience required for the task. Methods: The test was developed based...... measurements, Mann-Whitney U test could discriminate between experts and novices (p = .002), between experts and intermediates (p = .010), and between novices and intermediates (p = .036). In stent selection the experts performed significantly better than both the novices and the intermediates (p = .002 and p...... of competence in vessel analysis and stent graft selection for endovascular aortic repair. This was supported by strong validity evidence with good internal consistency and discriminatory ability. The tool may be used to facilitate training and certification of future endovascular specialists....

  10. Endovascular Treatment of an Aortobronchial Fistula

    International Nuclear Information System (INIS)

    Numan, Fueruezan; Arbatli, Harun; Yagan, Naci; Demirsoy, Ergun; Soenmez, Binguer

    2004-01-01

    A 67-year-old man operated on 8 years previously for type B aortic dissection presented with two episodes of massive hemoptysis. An aortobronchial fistula was suspected with spiral computed tomography angiography, and showed a small pseudoaneurysm corresponding to the distal anastomotic site. The patient underwent endovascular stent-graft implantation and is asymptomatic 8 months after the procedure

  11. Abdominal aortic aneurysm neck remodeling after Anaconda stent graft implantation.

    Science.gov (United States)

    Vukovic, Elisabeth; Czerny, Martin; Beyersdorf, Friedhelm; Wolkewitz, Martin; Berezowski, Mikolaj; Siepe, Matthias; Blanke, Philipp; Rylski, Bartosz

    2018-05-24

    The aim of this study was to define how the proximal landing zone changes geometrically after endovascular abdominal aortic aneurysm repair (EVAR) with the Anaconda (Vascutek, Inchinnan, United Kingdom) stent graft. Among 230 patients who underwent Anaconda stent graft implantation between 2005 and 2014, we included 126 with adequate computed tomography (CT) image quality and follow-up. CT analysis entailed the geometric changes in the main body, proximal rings, and proximal landing zone. The median CT follow-up was 2.0 years (345.8 patients-years). The proximal portion of the main body ring system flattened within the first year after EVAR, resulting in an up to 30° increase in the upper ring's angle in 40% patients and up to 40° increase in 24% patients. One year after EVAR, the upper ring angle increase slowed down. Aortic diameter measured at the level of the upper and lower ring expanded by 2 to 4 mm within 1 year, but remained unchanged afterward. The main body migrated continuously down toward the aortic bifurcation, attaining an average 6-mm increase in the distance between the superior mesenteric artery and main body within 4 years. Freedom from endoleak type IA was 95 ± 2% and 93 ± 3% after 1 and 4 years, respectively. The Anaconda main body ring system in its proximal portion flattens within the first year after EVAR, leading to an increase of 2 to 4 mm in the proximal landing zone's aortic diameter. The main body migrates slowly but continuously down toward the aortic bifurcation. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  12. Stent-Graft Repair of a Large Cervical Internal Carotid Artery Pseudoaneurysm Causing Dysphagia

    International Nuclear Information System (INIS)

    Gupta, Vivek; Niranjan, Khandelwal; Rawat, Lokesh; Gupta, A. K.

    2009-01-01

    Pseudoaneurysms of the cervical internal carotid artery (ICA) are rare and most frequently result from trauma, infection, or sometimes spontaneously. They have the potential to cause life-threatening hemorrhage; thus, their immediate management is necessary. Endovascular treatment by stent graft placement in the affected artery appears to be a safe and effective treatment option. We present a case of a child who presented with neck swelling and dysphagia caused by a ruptured cervical ICA pseudoaneurysm which was managed by stent graft placement.

  13. Retrograde ascending aortic dissection during or after thoracic aortic stent graft placement: insight from the European registry on endovascular aortic repair complications

    DEFF Research Database (Denmark)

    Eggebrecht, Holger; Thompson, Matt; Rousseau, Hervé

    2009-01-01

    BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic...

  14. Configuration affects parallel stent grafting results.

    Science.gov (United States)

    Tanious, Adam; Wooster, Mathew; Armstrong, Paul A; Zwiebel, Bruce; Grundy, Shane; Back, Martin R; Shames, Murray L

    2018-05-01

    A number of adjunctive "off-the-shelf" procedures have been described to treat complex aortic diseases. Our goal was to evaluate parallel stent graft configurations and to determine an optimal formula for these procedures. This is a retrospective review of all patients at a single medical center treated with parallel stent grafts from January 2010 to September 2015. Outcomes were evaluated on the basis of parallel graft orientation, type, and main body device. Primary end points included parallel stent graft compromise and overall endovascular aneurysm repair (EVAR) compromise. There were 78 patients treated with a total of 144 parallel stents for a variety of pathologic processes. There was a significant correlation between main body oversizing and snorkel compromise (P = .0195) and overall procedural complication (P = .0019) but not with endoleak rates. Patients were organized into the following oversizing groups for further analysis: 0% to 10%, 10% to 20%, and >20%. Those oversized into the 0% to 10% group had the highest rate of overall EVAR complication (73%; P = .0003). There were no significant correlations between any one particular configuration and overall procedural complication. There was also no significant correlation between total number of parallel stents employed and overall complication. Composite EVAR configuration had no significant correlation with individual snorkel compromise, endoleak, or overall EVAR or procedural complication. The configuration most prone to individual snorkel compromise and overall EVAR complication was a four-stent configuration with two stents in an antegrade position and two stents in a retrograde position (60% complication rate). The configuration most prone to endoleak was one or two stents in retrograde position (33% endoleak rate), followed by three stents in an all-antegrade position (25%). There was a significant correlation between individual stent configuration and stent compromise (P = .0385), with 31

  15. Late type III endoleak after thoracic endovascular aneurysm repair and previous infrarenal stent graft implantation - a case report and review of the literature.

    Science.gov (United States)

    Leszczyński, Jerzy; Macioch, Waldemar; Chudziński, Witold; Gałązka, Zbigniew

    2017-09-01

    Thoracic endovascular aortic repair (TEVAR) effectively improved the results of thoracic aortic aneurysm treatment. TEVAR is a less invasive procedure that can be performed under local anesthesia with shorter hospital stay. The perioperative morbidity and mortality rates are lower for endovascular than open repair, but the rate of secondary interventions is higher for TEVAR. We report a case of an elderly man with synchronous abdominal and thoracic aortic aneurysms. A type III dangerous endoleak was recognized 3 years after TEVAR. It was successfully repaired during an endovascular procedure. There were no new endoleaks after 12 months of follow-up. TEVAR may be the only option of treatment for risky and elderly patients. However, postoperative monitoring is necessary to exclude different types of endoleaks. Most of them undergo effective endovascular repair.

  16. 3D Stereoscopic Visualization of Fenestrated Stent Grafts

    International Nuclear Information System (INIS)

    Sun Zhonghua; Squelch, Andrew; Bartlett, Andrew; Cunningham, Kylie; Lawrence-Brown, Michael

    2009-01-01

    The purpose of this study was to present a technique of stereoscopic visualization in the evaluation of patients with abdominal aortic aneurysm treated with fenestrated stent grafts compared with conventional 2D visualizations. Two patients with abdominal aortic aneurysm undergoing fenestrated stent grafting were selected for inclusion in the study. Conventional 2D views including axial, multiplanar reformation, maximum-intensity projection, and volume rendering and 3D stereoscopic visualizations were assessed by two experienced reviewers independently with regard to the treatment outcomes of fenestrated repair. Interobserver agreement was assessed with Kendall's W statistic. Multiplanar reformation and maximum-intensity projection visualizations were scored the highest in the evaluation of parameters related to the fenestrated stent grafting, while 3D stereoscopic visualization was scored as valuable in the evaluation of appearance (any distortions) of the fenestrated stent. Volume rendering was found to play a limited role in the follow-up of fenestrated stent grafting. 3D stereoscopic visualization adds additional information that assists endovascular specialists to identify any distortions of the fenestrated stents when compared with 2D visualizations.

  17. Aortic Stent-Graft Infection Following Septic Complications of a Kidney Stone

    International Nuclear Information System (INIS)

    Berg, H. Rogier van den; Leijdekkers, Vanessa J.; Vahl, Anco

    2006-01-01

    A 73-year-old man was treated because of a renal pelvis blowout of the left kidney for which he received a nephrostomy catheter without antibiotic prophylaxis. Almost a year previously this patient had undergone endovascular repair of a symptomatic infrarenal abdominal aorta aneurysm. Four weeks after the diagnosis and treatment of the ruptured renal pelvis, a new computed tomography scan and ultrasound-guided fine needle aspiration confirmed the diagnosis of infected aortic stent-graft. An extra-anatomic axillo-uniiliac bypass and graft excision was performed. Two weeks after discharge the patient returned to the hospital with an occlusion of his left renal artery and died of renal failure. This is the first time an infected aortic stent-graft after a renal pelvis blowout has been reported. Although infections of aortic stent-grafts occur rarely, one should be aware of the possibility in aortic stent-graft patients undergoing abdominal procedures without antibiotic prophylaxis

  18. Endovascular repair of para-anastomotic aortoiliac aneurysms.

    LENUS (Irish Health Repository)

    Tsang, Julian S

    2009-11-01

    The purpose of this study is to evaluate the use of endovascular stent grafts in the treatment of para-anastomotic aneurysms (PAAs) as an alternative to high-risk open surgical repair. We identified all patients with previous open aortic aneurysm repair who underwent infrarenal endovascular aneurysm repair (EVAR) at our institution from June 1998 to April 2007. Patient demographics, previous surgery, and operative complications were recorded. One hundred forty-eight patients underwent EVAR during the study period and 11 patients had previous aortic surgery. Of these 11 redo patients, the mean age was 62 years at initial surgery and 71 years at EVAR. All patients were male. Initial open repair was for rupture in five (45%) patients. The average time between initial and subsequent reintervention was 9 years. All patients were ASA Grade III or IV. Fifty-five percent of the PAAs involved the iliac arteries, 36% the abdominal aorta, and 9% were aortoiliac. Ten patients had endovascular stent-grafts inserted electively, and one patient presented with a contained leak. Aorto-uni-iliac stent-grafts were deployed in seven patients, and bifurcated stent-grafts in four patients. A 100% successful deployment rate was achieved. Perioperative mortality was not seen and one patient needed surgical reintervention to correct an endoleak. Endovascular repair of PAAs is safe and feasible. It is a suitable alternative and has probably now become the treatment of choice in the management of PAAs.

  19. The Bolton Treovance abdominal stent-graft: European clinical trial design.

    Science.gov (United States)

    Chiesa, R; Riambau, V; Coppi, G; Zipfel, B; Llagostera, S; Marone, E M; Kahlberg, A

    2012-10-01

    Endovascular aortic repair (EVAR) has emerged as a promising, less invasive alternative to conventional open surgery for the treatment of infrarenal abdominal aortic aneurysms (AAAs). In the last 20 years, the application rate of EVAR and its clinical results have significantly improved thanks to the evolution of stent-grafts and endovascular delivery systems. However, further development is still needed to reduce the incidence of complications and secondary re-interventions. The Treovance abdominal aortic stent-graft (Bolton Medical, Barcelona, Spain) is a new-generation endovascular device, developed to increase flexibility, lower profile, improve deployment and sealing mechanisms. In particular, it is provided with some innovative features as a double layer of proximal barbs (suprarenal and infrarenal) for supplemental fixation, dull barbs between modules to avoid potential leg disconnections, detachable outer sheath provided with a new-design hemostatic valve, and a double improved mechanism (slow motion and "pin and pull") for precise stent-graft deployment. A European prospective, non-randomized, multi-institutional, "first-in-human" trial (the ADVANCE trial) was conducted from March to December 2011 to assess the safety and performance of the Treovance stent-graft system before commercialization. Thirty patients with anatomically suitable non-ruptured AAAs were enrolled at five clinical sites in Italy, Spain, and Germany. EVAR was completed successfully in all patients. The stent-graft was delivered and deployed safely even in heavily angulated or calcified anatomies. No 30-day device-related complications nor deaths were observed. Preliminary experience with the Treovance abdominal stent-graft within the ADVANCE trial was satisfactory with regard to technical success and perioperative clinical results. Follow-up data are needed to assess mid- and long-term clinical outcomes, along with durability of this new-generation endovascular device.

  20. Tissue Responses to Stent Grafts with Endo-Exo-Skeleton for Saccular Abdominal Aortic Aneurysms in a Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Il Young; Chung, Jin Wook; Kim, Hyo Cheol [Dept. of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul (Korea, Republic of); Choi, Young Ho; So Young Ho [Dept. of Radiology, Seoul National University Boramae Hospital, Seoul (Korea, Republic of); Kim, Hyun Beom [Dept. of Radiology, National Cancer Center, Goyang (Korea, Republic of); Min, Seung Kee [Dept. of Surgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Park, Jae Hyung [Dept. of Radiology, Gachon University Gil Medical Center, Incheon (Korea, Republic of)

    2014-10-15

    We evaluated the effect of close contact between the stent and the graft on the induction of endothelial covering on the stent graft placed over an aneurysm. Saccular abdominal aortic aneurysms were made with Dacron patch in eight dogs. The stent graft consisted of an inner stent, a expanded polytetrafluoroethylene graft, and an outer stent. After sacrificing the animals, the aortas with an embedded stent graft were excised. The aortas were inspected grossly and evaluated microscopically. The animals were sacrificed at two (n = 3), six (n = 3), and eight months (n = 2) after endovascular repair. In two dogs, the aortic lumen was occluded at two months after the placement. On gross inspection of specimens from the other six dogs with a patent aortic lumen, stent grafts placed over the normal aortic wall were covered by glossy white neointima, whereas, stent grafts placed over the aneurysmal aortic wall were covered by brownish neointima. On microscopic inspection, stent grafts placed over the normal aortic wall were covered by thin neointima (0.27 ± 0.05 mm, mean ± standard deviation) with an endothelial layer, and stent grafts placed over the aneurysmal aortic wall were covered by thick neointima (0.62 ± 0.17 mm) without any endothelial lining. Transgraft cell migration at the normal aortic wall was more active than that at the aneurysmal aortic wall. Close contact between the stent and the graft, which was achieved with stent grafts with endo-exo-skeleton, could not enhance endothelial covering on the stent graft placed over the aneurysms.

  1. Robot-Assisted Antegrade In-Situ Fenestrated Stent Grafting

    International Nuclear Information System (INIS)

    Riga, Celia V.; Bicknell, Colin D.; Wallace, Daniel; Hamady, Mohamad; Cheshire, Nicholas

    2009-01-01

    To determine the technical feasibility of a novel approach of in-situ fenestration of aortic stent grafts by using a remotely controlled robotic steerable catheter system in the porcine model. A 65-kg pig underwent robot-assisted bilateral antegrade in-situ renal fenestration of an abdominal aortic stent graft with subsequent successful deployment of a bare metal stent into the right renal artery. A 16-mm iliac extension covered stent served as the porcine aortic endograft. Under fluoroscopic guidance, the graft was punctured with a 20-G customized diathermy needle that was introduced and kept in place by the robotic arm. The needle was exchanged for a 4 x 20 mm cutting balloon before successful deployment of the renal stent. Robot-assisted antegrade in-situ fenestration is technically feasible in a large mammalian model. The robotic system enables precise manipulation, stable positioning, and minimum instrumentation of the aorta and its branches while minimizing radiation exposure.

  2. Stent grafting of acute hepatic artery bleeding following pancreatic head resection

    International Nuclear Information System (INIS)

    Stoupis, Christoforos; Ludwig, Karin; Triller, Juergen; Inderbitzin, Daniel; Do, Dai-Do

    2007-01-01

    The purpose of this study was to report the potential of hepatic artery stent grafting in cases of acute hemorrhage of the gastroduodenal artery stump following pancreatic head resection. Five consecutive male patients were treated because of acute, life-threatening massive bleeding. Instead of re-operation, emergency angiography, with the potential of endovascular treatment, was performed. Because of bleeding from the hepatic artery, a stent graft (with the over-the-wire or monorail technique) was implanted to control the hemmorhage by preserving patency of the artery. The outcome was evaluated. In all cases, the hepatic artery stent grafting was successfully performed, and the bleeding was immediately stopped. Clinically, immediately after the procedure, there was an obvious improvement in the general patient condition. There were no immediate procedure-related complications. Completion angiography (n=5) demonstrated control of the hemorrhage and patency of the hepatic artery and the stent graft. Although all patients recovered hemodynamically, three individuals died 2 to 10 days after the procedure. The remaining two patients survived, without the need for re-operation. Transluminal stent graft placement in the hepatic artery is a safe and technically feasible solution to control life-threatening bleeding of the gastroduodenal artery stump. (orig.)

  3. Directional tip control technique for optimal stent graft alignment in angulated proximal aortic landing zones

    Directory of Open Access Journals (Sweden)

    Toshio Takayama, MD, PhD

    2017-06-01

    Full Text Available Angulated anatomy in the aorta, such as tortuous infrarenal aortic necks or steep aortic arches, is a significant challenge for endovascular aortic repair because it often causes inadequate sealing and fixation, which may lead to treatment failure. We have developed a technique using off-the-shelf equipment to precisely control the deployment of stent grafts in challenging landing zones. The key of this technique is to create a through-and-through wire between two access sites and to use a guiding device over the wire. This technique is best used with stent grafts without nose cones. We present an endovascular aneurysm repair case and a thoracic endovascular aortic repair case with challenging proximal landing zones treated by this technique. In both cases, technical success was attained, and follow-up imaging demonstrated well-aligned stent grafts. Our directional tip control technique is easy and effective. It can be a good technical solution for endovascular aortic treatment in angulated anatomy.

  4. Balloon Tamponade Treatment of a Stent-graft Related Rupture with a Splenic Artery Pseudoaneurysm: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, See Hyung; Kim, Young Hwan [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2009-09-15

    An arterial rupture resulting from stent-graft placement of a splenic artery pseudoaneurysm is a life-threatening complication and immediate endovascular or surgical treatment is indicated. We report a case of a stentgraft related splenic artery rupture treated solely with a prolonged balloon catheter tamponade, which resulted in preservation of vessel patency

  5. Surgical Repair of a Post-traumatic Arteriovenous Fistula Complicated by Stent-Graft Misplacement

    International Nuclear Information System (INIS)

    Sahin, Sinan; Ciinar, Bayer; Bilgin, Sule N.; Celik, Levent; Eren, Ergin E.

    2005-01-01

    An arteriovenous fistula (AVF) is an abnormal connection between an artery and a vein which may result from a traumatic injury or occur as a congenital abnormality. It may be asymptomatic or may present with a variety of symptoms. Surgical or endovascular treatment can be preferred. We present a case of unsuccessful percutaneous treatment of a femoral AVF due to misplacement of the stent-grafts, necessitating surgical correction

  6. One-stage surgery in combination with thoracic endovascular grafting and resection of T4 lung cancer invading the thoracic aorta and spine

    OpenAIRE

    Sato, Seijiro; Goto, Tatsuya; Koike, Terumoto; Okamoto, Takeshi; Shoji, Hirokazu; Ohashi, Masayuki; Watanabe, Kei; Tsuchida, Masanori

    2017-01-01

    A novel strategy of one-stage surgery in combination with thoracic endovascular grafting and resection for T4 lung cancer invading the thoracic aorta and spine is described. A 56-year-old man with locally advanced lung cancer infiltrating the aortic wall and spine underwent neoadjuvant chemotherapy and thoracic irradiation, followed by en bloc resection of the aortic wall and spine with thoracic endovascular grafting. He developed postoperative chylothorax, but there were no stent graft-relat...

  7. Treatment of pseudoaneurysms with stent-graft: preliminary experience in 12 cases

    International Nuclear Information System (INIS)

    Liao Denghui; Ye Caisheng; Li Songqi; Ye Runyi; Chang Guangqi; Chen Wei; Li Xiaoxi; Wang Shenming

    2012-01-01

    Objective: To asses the clinical effect of stent-graft in the treatment of pseudoaneurysms. Methods: During the period from March 2008 to June 2011, 86 patients with pseudoaneurysms were admitted to the hospital, of whom stent-graft implantation was carried out in 12. The pseudoaneurysms were located at the thoracic aorta (n=4), abdominal aorta (n=3), common carotid artery (n=3), internal carotid artery (n=1) and right subclavian artery (n=1). All the patient were followed up for 5-43 months. The clinical results were analyzed. Results: The technical success rate for stent delivery was 100%. The pseudoaneurysms was immediately isolated after the procedure in all 12 cases. After endovascular exclusion with stent-graft, no leakage occurred and the blood flow distal to the parent artery was normal. All patients were followed up for a mean period of 23.5 months except one who lost in touch with the authors. One patient with coexisting Behcet's disease died of massive bleeding due to abdominal aortic rupture four months after operation. The other patients were in good clinical condition, and no complications such as stent stenosis, displacement, internal leakage etc. were observed in the follow-up period. Conclusion: The implantation of stent-graft has satisfactory short-term effect in treating pseudoaneurysms, although its long-term efficacy needs to be further observed. (authors)

  8. Importance of stent-graft design for aortic arch aneurysm repair

    Directory of Open Access Journals (Sweden)

    C Singh

    2017-02-01

    Full Text Available Aneurysm of the aorta is currently treated by open surgical repair or endovascular repair. However, when the aneurysm occurs in regions between the aortic arch and proximal descending aorta, it can be a complex pathology to treat due to its intricate geometry. When complex aortic aneurysms are treated with the conventional procedures, some of the patients present with significant post-operative complications and high mortality rate. Consequently, a clinically driven hybrid innovation known as the frozen elephant trunk procedure was introduced to treat complex aortic aneurysms. Although this procedure significantly reduces mortality rate and operating time, it is still associated with complications such as endoleaks, spinal cord ischemia, renal failure and stroke. Some of these complications are consequences of a mismatch in the biomechanical behaviour of the stent-graft device and the aorta. Research on complex aneurysm repair tended to focus more on the surgical procedure than the stent-graft design. Current stent-graft devices are suitable for straight vessels. However, when used to treat aortic aneurysm with complex geometry, these devices are ineffective in restoring the normal biological and biomechanical function of the aorta. A stent-graft device with mechanical properties that are comparable with the aorta and aortic arch could possibly lead to fewer post-operative complications, thus, better outcome for patients with complex aneurysm conditions. This review highlights the influence stent-graft design has on the biomechanical properties of the aorta which in turn can contribute to complications of complex aneurysm repair. Design attributes critical for minimising postoperative biomechanical mismatch are also discussed.

  9. Endovascular Repair of a Pseudoaneurysm of the Abdominal Aorta Secondary to Translumbar Aortography

    International Nuclear Information System (INIS)

    Mir, Naheed; Nunzio, Mario De; Pollock, John G

    2006-01-01

    This report describes an incidental finding of a pseudoaneurysm of the abdominal aorta on a computed tomography (CT) renal angiogram during investigation of chronic renal failure in a 73-year-old man. The patient had undergone a translumbar aortogram 20 years previously. An increase in the size of the aneurysm by 7 mm over 6 months prompted treatment and the aneurysm underwent successful endovascular repair with a custom-made stent-graft

  10. Aneurysm growth after late conversion of thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Hirofumi Kasahara

    2015-01-01

    Full Text Available A 69-year-old man underwent thoracic endovascular aortic repair of a descending aortic aneurysm. Three years later, he developed impending rupture due to aneurysmal expansion that included the proximal landing zone. Urgent open surgery was performed via lateral thoracotomy, and a Dacron graft was sewn to the previous stent graft distally with Teflon felt reinforcement. Postoperatively, four sequential computed tomography scans demonstrated that the aneurysm was additionally increasing in size probably due to continuous hematoma production, suggesting a possibility of endoleaks. This case demonstrates the importance of careful radiologic surveillance after endovascular repair, and also after partial open conversion.

  11. Comparison of midterm results for the Talent and Endurant stent graft.

    Science.gov (United States)

    't Mannetje, Yannick W; Cuypers, Philippe W M; Saleem, Ben R; Bode, Aron S; Teijink, Joep A W; van Sambeek, Marc R H M

    2017-09-01

    Stent graft evolution is often addressed as a cause for improved outcomes of endovascular aneurysm repair for patients with an abdominal aortic aneurysm. In this study, we directly compared the midterm result of Endurant stent graft with its predecessor, the Talent stent graft (both Medtronic, Santa Rosa, Calif). Patient treated from January 2005 to December 2010 in a single tertiary center in The Netherlands with a Talent or Endurant stent graft were eligible for inclusion. Ruptured abdominal aortic aneurysms or patients with previous aortic surgery were excluded. The primary end point was the Kaplan-Meier estimated freedom from secondary interventions. Secondary end points were perioperative outcomes and indications for secondary interventions. In total, 221 patients were included (131 Endurant and 90 Talent). At baseline, the median aortic bifurcation was narrower for the Endurant (30 mm vs 39 mm; P Talent and Endurant, respectively. The estimated freedom from secondary interventions at 30 days, 1 year, 5 years, and 7 years was 94.3%, 89.4%, 72.2%, and 64.1% for Talent and 96.8%, 89.3%, 75.2%, and 69.2% for Endurant (P = .528). The indication for secondary interventions does differ; more patients required an intervention for a proximal neck-related complication (type Ia endoleak or migration) in the Talent group (18.2% vs 4.8%; P = .001), whereas more interventions for iliac limb stenosis were seen in the Endurant group (0.0% vs 4.8%; P = .044). In a binomial regression analysis, suprarenal angulation, infrarenal neck length, and type of stent graft were independent predictors of neck-related complications. Evolution from the Talent stent graft into the Endurant has resulted in significant reduction of infrarenal neck-related complications; on the other hand, iliac interventions increased. The overall midterm secondary intervention rate was comparable. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  12. [Evaluation of Radiation Dose during Stent-graft Treatment Using a Hybrid Operating Room System].

    Science.gov (United States)

    Haga, Yoshihiro; Chida, Kouichi; Kaga, Yuji; Saitou, Kazuhisa; Arai, Takeshi; Suzuki, Shinichi; Iwaya, Yoshimi; Kumasaka, Eriko; Kataoka, Nozomi; Satou, Naoto; Abe, Mitsuya

    2015-12-01

    In recent years, aortic aneurysm treatment with stent graft grafting in the X-ray fluoroscopy is increasing. This is an endovascular therapy, because it is a treatment which includes the risk of radiation damage, having to deal with radiation damage, to know in advance is important. In this study, in order to grasp the trend of exposure stent graft implantation in a hybrid operating room (OR) system, focusing on clinical data (entrance skin dose and fluoroscopy time), was to count the total. In TEVAR and EVAR, fluoroscopy time became 13.40 ± 7.27 minutes, 23.67 ± 11.76 minutes, ESD became 0.87 ± 0.41 mGy, 1.11 ± 0.57 mGy. (fluoroscopy time of EVAR was 2.0 times than TEVAR. DAP of EVAR was 1.2 times than TEVAR.) When using the device, adapted lesions and usage are different. This means that care changes in exposure-related factors. In this study, exposure trends of the stent graft implantation was able to grasp. It can be a helpful way to reduce/optimize the radiation dose in a hybrid OR system.

  13. [Successful correction with stent-graft of coronary artery rupture after angioplasty].

    Science.gov (United States)

    Demin, V V

    2003-01-01

    Rupture and perforation of coronary arteries complicate in average 0.5% of radiosurgical coronary interventions and often are accompanied by serious consequences and high mortality. According to-type of coronary perforation different methods of correction are used, ranging from conservative measures to urgent cardiosurgical interventions. Coronary stent-grafts with 'sandwich' type of construction ore composed from two metal stents and PTFE layer between them. Development of such stents enabled effective radioguided endovascular repair of coronary ruptures. The paper presents the first Russian experience of stout-graft implantation for coronary artery rupture occurred during direct stenting of proximal anterior descending artery and balloon angioplasty in distal segment. The rupture occurred probably because of wall fragility between affected segment and muscular bridge. Stent-graft JoStent 16 mm in length connected with 3-mm balloon was implanted with subsequent complete restitution of blood flow, resolution of pain syndrome and ECG normalization. Echocardiography in operative theatre and one day after surgery showed no intrapericardial fluid. Stent-graft devices for urgent implantation in cases of coronary rupture must be included into obligatory equipment of radiosurgical facilities.

  14. Early and midterm outcomes of open stent-graft treatment for distal aortic arch aneurysm

    International Nuclear Information System (INIS)

    Yamada, Kazunori; Mochizuki, Takaaki; Tsubota, Hideki; Funamoto, Masaki

    2008-01-01

    The aim of this study was to investigate early and late outcomes for open stent-graft treatment, which was introduced as a less-invasive technique for thoracic aortic aneurysm of the distal arch, and to clarify the validity of and indications for this treatment. We retrospectively investigated 38 patients with thoracic aortic aneurysm of the distal arch who underwent open stent-graft placement at our hospital between June 2000 and September 2006. Five patients died in hospital (hospital mortality 13.2%). Age at the time of surgery and onset of postoperative paraplegia were identified as risk factors. Four patients (10.5%) had postoperative paraplegia, but no significant risk factors were seen. The size of the aneurysm was clearly reduced in 18 of the 25 patients (75.8%), in whom computed tomography was performed after discharge, and late outcomes were good. Mural thrombus thickness on the stent landing zone of <4 mm was a predictor for aneurysm shrinkage. Seven patients died during the late period, and the 5-year survival rate among hospital survivors was 80.1%. Early outcomes for open stent-graft are not necessarily good, and late survival is also not excellent. Open stent-graft thus cannot be regarded as an ideal technique for all patients with distal aortic arch aneurysm. However, after aneurysm shrinkage was confirmed during the early period, late outcomes were good. Absence of thick mural thrombus on the stent landing zone may represent a good indication for open stent-graft surgery. (author)

  15. Unusual rapid evolution of type B aortic dissection in a marfan patient following heart transplantation: successful endovascular treatment.

    Science.gov (United States)

    Botta, L; Russo, V; Grigioni, F; Arpesella, G; Rocchi, G; Di Bartolomeo, R; Fattori, R

    2006-10-01

    A patient with Marfan syndrome with previous Bentall operation for mitral and tricuspid valve repair, required orthotopic cardiac transplantation for end stage cardiomyopathy. Postoperatively he suffered type-B aortic dissection, despite normal aortic diameters. Following sudden increase of aortic diameters, two years later, he underwent successful stent graft implantation. In patients with Marfan syndrome, post transplantation morbidity is high, with a 40% incidence of thoracic aortic dissection. This case highlights the potential of endovascular approach for treating post-transplantation aortic dissection.

  16. [A re-operative case of bentall operation and aortic arch replacement using a stent graft for a Marfan syndrome, post sternum turnover and post mitral valve replacement].

    Science.gov (United States)

    Sasaki, H; Aomi, S; Noji, S; Uwabe, K; Kihara, S; Kurihara, H; Koyanagi, H

    2001-09-01

    A 36-year-old male with Marfan syndrome succesfully underwent Bentall operation and aortic arch replacement using a stent graft as an elephant trunk. He had received MVR with sternum turn over 14 years previously. Median sternotomy was performed. Under circulatory arrest with rertograde cerebral perfusion we performed Bentall operation and aortic arch replacement using a stent graft. The sternum was cured well. Retractive breathing was not detected. This surgical procedure was effective for cardiovascular disease with Marfan syndrome.

  17. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    International Nuclear Information System (INIS)

    Sun, Z.; Allen, Y.; Fitzsimmons, B.; Hartely, D.; Lawrence-Brown, M.

    2007-01-01

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  18. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Z. [Dept. of Imaging and Applied Physics, Curtin Univ. of Tech., Perth, WA (Australia); Allen, Y.; Fitzsimmons, B.; Hartely, D. [Cook R and D, WA (Australia); Lawrence-Brown, M. [Dept. of Public Health, Curtin Univ. of Tech., Perth, WA (Australia)

    2007-06-15

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  19. Endovascular Aortic Aneurysm Repair with Chimney and Snorkel Grafts: Indications, Techniques and Results

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rakesh P., E-mail: rpatel9@nhs.net [Northwick Park Hospital, Department of Vascular Radiology (United Kingdom); Katsargyris, Athanasios, E-mail: kthanassos@yahoo.com; Verhoeven, Eric L. G., E-mail: Eric.Verhoeven@klinikum-nuernberg.de [Klinikum Nuernberg, Department of Vascular and Endovascular Surgery (Germany); Adam, Donald J., E-mail: donald.adam@tiscali.co.uk [Heartlands Hospital, Department of Vascular Surgery (United Kingdom); Hardman, John A., E-mail: johnhardman@doctors.org.uk [Royal United Hospital Bath, Department of Vascular Radiology (United Kingdom)

    2013-12-15

    The chimney technique in endovascular aortic aneurysm repair (Ch-EVAR) involves placement of a stent or stent-graft parallel to the main aortic stent-graft to extend the proximal or distal sealing zone while maintaining side branch patency. Ch-EVAR can facilitate endovascular repair of juxtarenal and aortic arch pathology using available standard aortic stent-grafts, therefore, eliminating the manufacturing delays required for customised fenestrated and branched stent-grafts. Several case series have demonstrated the feasibility of Ch-EVAR both in acute and elective cases with good early results. This review discusses indications, technique, and the current available clinical data on Ch-EVAR.

  20. Magnetizable stent-grafts enable endothelial cell capture

    Energy Technology Data Exchange (ETDEWEB)

    Tefft, Brandon J. [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Uthamaraj, Susheil [Division of Engineering, Mayo Clinic, Rochester, MN (United States); Harburn, J. Jonathan [School of Medicine, Pharmacy and Health, Durham University, Stockton-on-Tees (United Kingdom); Hlinomaz, Ota [Department of Cardioangiology, St. Anne' s University Hospital, Brno (Czech Republic); Lerman, Amir [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Dragomir-Daescu, Dan [Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN (United States); Sandhu, Gurpreet S., E-mail: sandhu.gurpreet@mayo.edu [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States)

    2017-04-01

    Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance. - Highlights: • Magnetic stent-grafts were made from 2205 steel stents and polyurethane nanofibers. • Stent-grafts remained patent and formed a thin and uniform neointima when implanted. • Stent-grafts captured endothelial cells labeled with magnetic nanoparticles.

  1. Adolescent External Iliac Artery Trauma: Recurrent Aneurysmal Dilatation of an Iliofemoral Saphenous Vein Graft Treated by Stent-Grafting

    International Nuclear Information System (INIS)

    Lenton, James; Davies, John; Homer-Vanniasinkam, S.; McPherson, Simon

    2008-01-01

    An adolescent male sustained a severe penetrating injury to the external iliac artery. Emergency surgical revascularization was with a reversed long saphenous vein interposition graft. The primary graft and the subsequent revision graft both became aneurysmal. The second graft aneurysm was successfully excluded by endovascular stent-grafts with medium-term primary patency. A venous graft was used initially rather than a synthetic graft to reduce the risk of infection and the potential problems from future growth. Aneurysmal dilatation of venous grafts in children and adolescents is a rare but recognized complication. To the best of our knowledge, exclusion of these aneurysms with stent-grafts has not been previously reported in the adolescent population.

  2. Risk factors for stent graft thrombosis after transjugular intrahepatic portosystemic shunt creation.

    Science.gov (United States)

    Jahangiri, Younes; Kerrigan, Timothy; Li, Lei; Prosser, Dominik; Brar, Anantnoor; Righetti, Johnathan; Schenning, Ryan C; Kaufman, John A; Farsad, Khashayar

    2017-12-01

    To identify risk factors of stent graft thrombosis after transjugular intrahepatic portosystemic shunt (TIPS) creation. Patients who underwent TIPS creation between June 2003 and January 2016 and with follow-up assessing stent graft patency were included (n=174). Baseline comorbidities, liver function, procedural details and follow-up liver function tests were analyzed in association with hazards of thrombosis on follow-up. Competing risk cox regression models were used considering liver transplant after TIPS creation as the competing risk variable. One-, 2- and 5-year primary patency rates were 94.1%, 91.7% and 78.2%, respectively. Patient age [sub-hazard ratio (sHR): 1.13; P=0.001], body mass index (BMI) value for trend=0.017). Older age, lower BMI and higher post-TIPS portosystemic gradients were associated with higher hazards of shunt thrombosis after TIPS creation using stent grafts. Higher rates of shunt thrombosis were seen in patients for whom TIPS creation was clinically unsuccessful. The association between TIPS thrombosis and higher post-TIPS portosystemic gradients may indicate impaired flow through the shunt, a finding which may be technical or anatomic in nature and should be assessed before procedure completion.

  3. Endovascular treatment for arterial injuries of skull base

    International Nuclear Information System (INIS)

    Li Tianxiao; Bai Weixing; Zai Suiting; Wang Ziliang; Xue Jiangyu

    2008-01-01

    Objective: To explore the role of endovascular techniques in treatment for arterial injuries of skull base. Methods: A total of 53 consecutive cases suffered from skull base arterial injuries were enrolled in our hospital from Oct 2004 to May 2007, including 44 male and 9 female cases with average age of 23.3 years. Thirty-nine cases presented with pulsatile exophthalmos and intracranial vascular murmur, cerchnus and dysphagia in another 9, epistaxis in the remaining 5 cases. Diagnosis of 39 carotid cavernous fistulae (CCF)and 14 carotid pseudoaneurysm were performed by angiography (DSA). Alternative endovascular procedures were performed depending on lesions characteristics and follow-up was done by telephone and outpatient work up. Results: Procedures were performed involving 56 carotid arteries in all 53 cases including 34 CCF with embolization of detachable balloon(33 cases), 3 with balloon and coils, and 3 by stent-graft placement. 8 carotid pseudoaneurysms were cured by parent artery occlusion with balloon, 2 experienced endovascular isolation with balloon and coils, and 4 with stent-graft. Follow-up for mean 9.5 months (range from 2 to 25 months) revealed that the chief symptoms of 45 cases (85%) were relieved within 6 months after the procedure but ocular movement and visual disorder remained in 8 cases (15%)till 12 months. Six pseudoaneurysms and 3 residual leak were found in reexamination, of which 2 cases underwent intervention again 2 and 3 months later due to dural arterial-venous fistula in cavernous sinus, respectively. Conclusions: Endovascular treatment is safe and effective therapeutic option with minimal invasion for skull base arterial injuries. Detachable balloon embolization is the first choice for CCF and carotid pseudoaneurysm. Spring coil packing and stent-graft implantation should be in alternation as combination for special cases. (authors)

  4. Penetrating Atherosclerotic Ulcer of the Abdominal Aorta Involving the Celiac Trunk Origin and Superior Mesenteric Artery Occlusion: Endovascular Treatment

    International Nuclear Information System (INIS)

    Ferro, Carlo; Rossi, Umberto G.; Petrocelli, Francesco; Seitun, Sara; Robaldo, Alessandro; Mazzei, Raffaele

    2011-01-01

    We describe a case of endovascular treatment in a 64-year-old woman affected by a penetrating atherosclerotic ulcer (PAU) of the abdominal aorta with a 26-mm pseudoaneurysm involving the celiac trunk (CT) origin and with superior mesenteric artery (SMA) occlusion in the first 30 mm. The patient underwent stenting to treat the SMA occlusion and subsequent deployment of a custom-designed fenestrated endovascular stent-graft to treat the PAU involving the CT origin. Follow-up at 6 months after device placement demonstrated no complications, and there was complete thrombosis of the PAU and patency of the two branch vessels.

  5. Perfect and least invasive sealing technique on the lesser curvature of the aortic arch: application of a novel stent graft to an aneurysm developing on a postoperative ductus arteriosus.

    Science.gov (United States)

    Soeda, Takeshi; Yokoi, Yoshihiko; Yuri, Koichi; Saito, Yuuhei; Setozaki, Shuji; Harada, Hisao

    2013-01-01

    A 78-year-old woman who underwent an operation for a patent ductus arteriosus (PDA) about thirty years ago developed an aneurysm on the aortic side of the remnant ductal tissue. To avoid risky, open surgery, we performed endovascular aortic therapy using a novel stent graft (SG), which was pre-curved, fenestrated and custom-made type. This graft was designed to configure to the patient's whole aortic arch anatomy, and was capable of accurately adjusting its fenestrations to the arch branch orifices during the procedure. The operation was successful, and the patient was discharged uneventfully on 16th postoperative day. The advantage of this fenestrated SG is close sealing, especially over the lesser curvature of the arch. This device could be a simple and effective option to deal with an otherwise normal aortic arch with such a ductus-related localized lesion.

  6. Intravascular stent graft with polyurethane and metallic stent: experimental study

    International Nuclear Information System (INIS)

    Do, Young Soo; Lee, Won Jae; Kim, Boo Kyung Han; Park, Jae Hyung; Lee, Hak Jong; Lee, Sang Hyun; Kim, Sung Hyun; Kim, Jong Won; Ha, Jongwon

    1997-01-01

    To evaluate the usefulness of a new model of the stent graft, and of tissue response related to placement of the stent graft. The stent graft was constructed from polyurethane (Pellethane) graft and Hanaro stent(12mm in diameter, 45mm in length, 10 bends). A stent grafts was inserted into the lower thoracic aorta in each of six adult mongrel dogs(body weight, 12-16kg). At one, two, four, and six months, follow-up studies of angiography and spiral CT angiography were preformed to evaluate wascular patency, vascular stenosis, and thrombus formation. Two dogs were sacrificed at 1month, 2months, and 6months after insertion of the stent graft and macroscopic, light microscopic, and scanning electron microscopic examinations of the aortic segment including the stent graft were performed to evaluate intimal hyperplasia, endothelial growth to the graft, and thrombus formation. During follow-up at one, two, four, and six months, angiography or spiral CT angiography showed 20-100% luminal stenosis or occlusion of the lower thoracic aorta by the thrombus and perigraft leaks in three dogs(50%), and collateral vessels caused by occlusion of the aorta in two (33.3%). On gross examination, there were thrombi of 1-5mm thickness at the graft portions in all dogs, and this thickness gradually increased. The mean thickness of intimal hyperplasia at the stent portion gradually increased from 120μm to 227μm and the mean thickness of intimal hyperplasia at the graft portion from 93μm to 914μm. This thickness was greater at the graft portion than at the stent portion. Scanning electron microscopy showed elliptical endothelial lining on the neointimal surfaces at each end of the graft. Thrombi caused stenosis or occlusion of the stent graft. In order for such a graft to be ideal, further study is needed

  7. Heparin surface stent-graft for the treatment of a carotid pseudoaneurysm.

    Science.gov (United States)

    Tsolaki, Elpiniki; Elpiniki, Tsolaki; Salviato, Elisabetta; Rocca, Tiberio; Braccini, Lucia; Galeotti, Roberto; Mascoli, Francesco

    2010-10-01

    Carotid pseudoaneurysms are a rare consequence of carotid surgery, trauma, and infection. Historically, carotid aneurysms and pseudoaneurysms were treated surgically. However, endovascular techniques have recently become a valid alternative for the treatment of carotid pseudoaneurysms. The case of a 57-year-old male patient with a pseudoaneurysm of the right internal carotid artery is described. The patient came to our unit with a painless and pulsatile mass in the neck, which was growing slowly. Five years earlier, he had undergone surgery on a saccular aneurysm located on the distal extracranial segment of the right internal carotid artery. The pseudoaneurysm was successfully treated with a heparin surface Viabahn stent-graft system (Gore AL, Flagstaff, AZ). Heparin surface stent-grafts can be used for the treatment of carotid lesions and may offer protection against intimal hyperplasia and thrombosis. Further studies are needed to evaluate the long-term results. Copyright © 2010 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  8. Magnetizable stent-grafts enable endothelial cell capture

    Science.gov (United States)

    Tefft, Brandon J.; Uthamaraj, Susheil; Harburn, J. Jonathan; Hlinomaz, Ota; Lerman, Amir; Dragomir-Daescu, Dan; Sandhu, Gurpreet S.

    2017-04-01

    Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance.

  9. CASE REPORT CASE CASE Endovascular stent grafting of ...

    African Journals Online (AJOL)

    Page 1 ... indicate sufficient length for a good 'landing zone' to avoid any possible occlusion of the LSA. A sharply angulated curve between the aortic arch and thoracic aorta was noted, however; ... Nitinol support structure which enables it to self-expand and provide sealing by radial force. In addition, there are sealing cuffs ...

  10. Combined open proximal and stent-graft distal repair for distal arch aneurysms: an alternative to total debranching.

    Science.gov (United States)

    Zierer, Andreas; Sanchez, Luis A; Moon, Marc R

    2009-07-01

    We present herein a novel, combined, simultaneous open proximal and stent-graft distal repair for complex distal aortic arch aneurysms involving the descending aorta. In the first surgical step, the transverse arch is opened during selective antegrade cerebral perfusion, and a Dacron graft (DuPont, Wilmington, DE) is positioned down the descending aorta in an elephant trunk-like fashion with its proximal free margin sutured circumferentially to the aorta just distal to the left subclavian or left common carotid artery. With the graft serving as the new proximal landing zone, subsequent endovascular repair is performed antegrade during rewarming through the ascending aorta.

  11. Endolymphatic Thoracic Duct Stent-Graft Reconstruction for Chylothorax: Approach, Technical Success, Safety, and Short-term Outcomes.

    Science.gov (United States)

    Srinivasa, Rajiv N; Chick, Jeffrey Forris Beecham; Hage, Anthony N; Gemmete, Joseph J; Murrey, Douglas C; Srinivasa, Ravi N

    2018-04-01

    To report approach, technical success, safety, and short-term outcomes of thoracic duct stent-graft reconstruction for the treatment of chylothorax. Two patients, 1 (50%) male and 1 (50%) female, with mean age of 38 years (range: 16-59 years) underwent endolymphatic thoracic duct stent-graft reconstruction between September 2016 and July 2017. Patients had radiographic left-sided chylothoraces (n = 2) from idiopathic causes (n = 1) and heart transplantation (n = 1). In both (100%) patients, antegrade lymphatic access was used to opacify the thoracic duct after which retrograde access was used for thoracic duct stent-graft placement. Pelvic lymphangiography technical success, antegrade cisterna chyli cannulation technical success, thoracic duct opacification technical success, retrograde thoracic duct access technical success, thoracic duct stent-graft reconstruction technical success, ethiodized oil volume, contrast volume, estimated blood loss, procedure time, fluoroscopy time, radiation dose, clinical success, complications, deaths, and follow-up were recorded. Pelvic lymphangiography, antegrade cisterna chyli cannulation, thoracic duct opacification, retrograde thoracic duct access, and thoracic duct stent-graft reconstruction were technically successful in both (100%) patients. Mean ethiodized oil volume was 8 mL (range: 5-10 mL). Mean contrast volume was 13 mL (range: 5-20 mL). Mean estimated blood loss was 13 mL (range: 10-15 mL). Mean fluoroscopy time was 50.4 min (range: 31.2-69.7 min). Mean dose area product and reference air kerma were 954.4 μGmy 2 (range: 701-1,208 μGmy 2 ) and 83.5 mGy (range: 59-108 mGy), respectively. Chylothorax resolved in both (100%) patients. There were no minor or major complications directly related to the procedure. Thoracic duct stent-graft reconstruction may be a technically successful and safe alternative to thoracic duct embolization, disruption, and surgical ligation for the treatment of chylothorax

  12. Endovascular Therapy of Ruptured Abdominal Aortic Aneurysm: Mid- and Long-Term Results

    International Nuclear Information System (INIS)

    Kubin, Klaus; Sodeck, Gottfried H.; Teufelsbauer, H.; Nowatschka, Bernd; Kretschmer, Georg; Lammer, Johannes; Schoder, Maria

    2008-01-01

    As an alternative to open aneurysm repair, emergency endovascular aortic repair (EVAR) has emerged as a promising technique for ruptured abdominal aortic aneurysm (rAAA) within the last decade. The aim of this retrospective study is to present early and late outcomes of patients treated with EVAR for rAAA. Twenty-two patients (5 women, 17 men; mean age, 74 years) underwent EVAR for rAAA between November 2000 and April 2006. Diagnostic multislice computed tomography angiography was performed prior to stent-graft repair to evaluate anatomical characteristics and for follow-up examinations. Periprocedural patient characteristics and technical settings were evaluated. Mortality rates, hospital stay, and early and late complications, within a mean follow-up time of 744 ± 480 days, were also assessed. Eight of 22 patients were hemodynamically unstable at admission. Stent-graft insertion was successful in all patients. The total early complication rate was 54%, resulting in a 30-day mortality rate of 23%. The median intensive care unit stay was 2 days (range, 2-48 days), and the median hospital stay was 16 days (range, 9-210 days). During the follow-up period, three patients suffered from stent-graft-related complications. The overall mortality rate in our study group was 36%. EVAR is an acceptable, minimally invasive treatment option in patients with acute rAAA, independent of the patient's general condition. Short- and long-term outcomes are definitely comparable to those with open surgical repair procedures

  13. Outcomes of AV Fistulas and AV Grafts after Interventional Stent-Graft Deployment in Haemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Schmelter, Christopher, E-mail: christopher.schmelter@klinikum-ingolstadt.de; Raab, Udo, E-mail: udo.raab@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany); Lazarus, Friedrich, E-mail: friedrich.lazarus@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Nephrology (Germany); Ruppert, Volker, E-mail: volker.ruppert@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Vascular Surgery (Germany); Vorwerk, Dierk, E-mail: dierk.vorwerk@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany)

    2015-08-15

    PurposeThe study was designed to assess outcomes of arteriovenous (AV) accesses after interventional stent-graft deployment in haemodialysis patients.Materials and Methods63 haemodialysis patients with 66 AV fistulas and AV grafts were treated by interventional stent-graft deployment from 2006 to 2012 at our hospital. Data of these patients were retrospectively analysed for location of deployed stent-grafts, occurrence and location of (re-)stenosis and (re-)thrombosis. Complex stenosis was the most frequent indication for stent-graft deployment (45.5 %), followed by complications of angioplasty with vessel rupture or dissection (31.8 %).ResultsA high rate of procedural success was achieved (98.5 %). The most frequent location of the deployed stent-graft was the draining vein (66.7 %). Stent-graft deployment was more frequent in AV grafts than in AV fistulas. Primary patency was 45.5 % at 6 month, 31.3 % at 12 month and 19.2 % at 24 month. Primary patency was significantly better for AV fistulas than for AV grafts with deployed stent-grafts. Patency of the deployed stent-graft was much better than overall AV access primary patency with deployed stent-graft. Re-stenosis with thrombosis was the most frequent indication for re-intervention. Most frequent location of re-stenosis was the draining vein (37.1 %), followed by stenosis at the AV access (29.5 %) and the deployed stent-graft (23.5 %).ConclusionRe-stenosis and re-thrombosis remain frequent in AV fistulas and AV grafts in haemodialysis patients despite stent-graft deployment. Re-stenosis of the deployed stent-graft is, only in the minority of the cases, responsible for AV access dysfunction.

  14. Miscellaneous Endovascular Treatment of Ruptured Hepatic Artery Pseudoaneurysms after Pylorus Preserving Pancreaticoduodenectomy

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ung Rae; Lee, Young Hwan [Dept. of Radiology, Daegu Catholic University Medical Center, Catholic of Daegu University School of Medicine, Daegu (Korea, Republic of); Ahn, Eun Joung; Kim, See Hyung; Kim, Young Hwan [Dept. of Radiology, Keimyung University Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2012-03-15

    To assess the feasibility and safety of the endovascular treatment of ruptured hepatic artery pseudoaneurysms after pylorus preserving pancreaticoduodenectomy (PPPD). Thirteen patients with hepatic artery pseudoaneurysm after PPPD were enrolled. Various endovascular techniques were used depending on the sites and morphologies of the pseudoaneurysms. Five cases were treated by coil embolization, five with stent-graft, one by thrombin injection and coil embolization, one with stent-graft and coil embolization, and one with N-butyl cyanoacrylate (NBCA) injection. Computed tomography scans and liver function test were performed after the procedures. Pseudoaneurysm exclusion and bleeding cessation was achieved in all patients. In four patients that underwent coil or NBCA embolization of the hepatic artery, aspartate transaminase (AST) and alanine transaminase (ALT) were markedly elevated. Two of these four patients with narrowing of the portal vein due to surrounding hematoma died of hepatic infarction or hepatic abscess. In other nine patients, AST and ALT were unchanged. In the 11 surviving patients, normal hepatic function and complete pseudoaneurysm disappearance were achieved during follow-up. Endovascular treatment of ruptured hepatic artery pseudoaneurysms can be considered as a feasible and safe method. However, complete occlusion of the hepatic artery with coils should be avoided in patients with inadequate portal flow.

  15. Endovascular Repair of Abdominal Aortic Aneurysms in the Presence of a Transplanted Kidney

    International Nuclear Information System (INIS)

    Silverberg, Daniel; Yalon, Tal; Halak, Moshe

    2015-01-01

    PurposeTo present our experience performing endovascular repair of abdominal aortic aneurysms in kidney transplanted patients.MethodsA retrospective review of all patients who underwent endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA) performed at our institution from 2007 to 2014. We identified all patients who had previously undergone a kidney transplant. Data collected included: comorbidities, preoperative imaging modalities, indication for surgery, stent graft configurations, pre- and postoperative renal function, perioperative complications, and survival rates.ResultsA total of 267 EVARs were performed. Six (2 %) had a transplanted kidney. Mean age was 74 (range, 64–82) years; five were males. Mean time from transplantation to EVAR was 7.5 (range, 2–12) years. Five underwent preoperative planning with noncontrast modalities only. Devices used included bifurcated (n = 3), aortouniiliac (n = 2), and tube (n = 1) stent grafts. Technical success was achieved in all patients. None experienced deterioration in renal function. Median follow-up was 39 (range, 6–51) months. Four patients were alive at the time of the study. Two patients expired during the period of follow-up from unrelated causes.ConclusionsEVAR is an effective modality for the management of AAAs in the coexistence of a transplanted kidney. It can be performed with minimal morbidity and mortality without harming the transplanted kidney. Special consideration should be given to device configuration to minimize damage to the renal graft

  16. Endovascular Repair of Abdominal Aortic Aneurysms in the Presence of a Transplanted Kidney

    Energy Technology Data Exchange (ETDEWEB)

    Silverberg, Daniel, E-mail: silverberg-d@msn.com; Yalon, Tal; Halak, Moshe [The Chaim Sheba Medical Center, The Department of Vascular Surgery (Israel)

    2015-08-15

    PurposeTo present our experience performing endovascular repair of abdominal aortic aneurysms in kidney transplanted patients.MethodsA retrospective review of all patients who underwent endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA) performed at our institution from 2007 to 2014. We identified all patients who had previously undergone a kidney transplant. Data collected included: comorbidities, preoperative imaging modalities, indication for surgery, stent graft configurations, pre- and postoperative renal function, perioperative complications, and survival rates.ResultsA total of 267 EVARs were performed. Six (2 %) had a transplanted kidney. Mean age was 74 (range, 64–82) years; five were males. Mean time from transplantation to EVAR was 7.5 (range, 2–12) years. Five underwent preoperative planning with noncontrast modalities only. Devices used included bifurcated (n = 3), aortouniiliac (n = 2), and tube (n = 1) stent grafts. Technical success was achieved in all patients. None experienced deterioration in renal function. Median follow-up was 39 (range, 6–51) months. Four patients were alive at the time of the study. Two patients expired during the period of follow-up from unrelated causes.ConclusionsEVAR is an effective modality for the management of AAAs in the coexistence of a transplanted kidney. It can be performed with minimal morbidity and mortality without harming the transplanted kidney. Special consideration should be given to device configuration to minimize damage to the renal graft.

  17. Comparison of long-term clinical outcome between patients with chronic versus acute type B aortic dissection treated by implantation of a stent graft: a single-center report

    Directory of Open Access Journals (Sweden)

    Chen SL

    2013-04-01

    Full Text Available Shao-Liang Chen, Jian-Cheng Zhu, Xiao-Bo Li, Fei Ye, Jun-Jie Zhang, Zhi-Zhong Liu, Nai-Liang Tian, Song Lin, Cheng-Yu Lv Nanjing First Hospital, Nanjing Medical University, Nanjing, People's Republic of China Background: Stent grafting for treatment of type B aortic dissection has been extensively used. However, the difference in the long-term clinical outcome between patients with chronic versus acute type B aortic dissection remains unknown. This study aimed to analyze the difference in long-term clinical outcome after endovascular repair for patients with chronic (93% complete false-lumen thrombosis. Untreated tear and type I endoleak were predictors of clinical events during follow-up. Conclusion: Comparable long-term clinical results were achieved in patients with chronic or acute type B aortic dissection after implantation of a stent graft. Keywords: aortic dissection, endovascular repair, procedure-related events, propensity score matching

  18. Endovascular Management of Acute Bleeding Arterioenteric Fistulas

    International Nuclear Information System (INIS)

    Leonhardt, Henrik; Mellander, Stefan; Snygg, Johan; Loenn, Lars

    2008-01-01

    The objective of this study was to review the outcome of endovascular transcatheter repair of emergent arterioenteric fistulas. Cases of abdominal arterioenteric fistulas (defined as a fistula between a major artery and the small intestine or colon, thus not the esophagus or stomach), diagnosed over the 3-year period between December 2002 and December 2005 at our institution, were retrospectively reviewed. Five patients with severe enteric bleeding underwent angiography and endovascular repair. Four presented primary arterioenteric fistulas, and one presented a secondary aortoenteric fistula. All had massive persistent bleeding with hypotension despite volume substitution and transfusion by the time of endovascular management. Outcome after treatment of these patients was investigated for major procedure-related complications, recurrence, reintervention, morbidity, and mortality. Mean follow-up time was 3 months (range, 1-6 months). All massive bleeding was controlled by occlusive balloon catheters. Four fistulas were successfully sealed with stent-grafts, resulting in a technical success rate of 80%. One patient was circulatory stabilized by endovascular management but needed immediate further open surgery. There were no procedure-related major complications. Mean hospital stay after the initial endovascular intervention was 19 days. Rebleeding occurred in four patients (80%) after a free interval of 2 weeks or longer. During the follow-up period three patients needed reintervention. The in-hospital mortality was 20% and the 30-day mortality was 40%. The midterm outcome was poor, due to comorbidities or rebleeding, with a mortality of 80% within 6 months. In conclusion, endovascular repair is an efficient and safe method to stabilize patients with life-threatening bleeding arterioenteric fistulas in the emergent episode. However, in this group of patients with severe comorbidities, the risk of rebleeding is high and further intervention must be considered

  19. Development of tissue-engineered self-expandable aortic stent grafts (Bio stent grafts) using in-body tissue architecture technology in beagles.

    Science.gov (United States)

    Kawajiri, Hidetake; Mizuno, Takeshi; Moriwaki, Takeshi; Ishibashi-Ueda, Hatsue; Yamanami, Masashi; Kanda, Keiichi; Yaku, Hitoshi; Nakayama, Yasuhide

    2015-02-01

    In this study, we aimed to describe the development of tissue-engineered self-expandable aortic stent grafts (Bio stent graft) using in-body tissue architecture technology in beagles and to determine its mechanical and histological properties. The preparation mold was assembled by insertion of an acryl rod (outer diameter, 8.6 mm; length, 40 mm) into a self-expanding nitinol stent (internal diameter, 9.0 mm; length, 35 mm). The molds (n = 6) were embedded into the subcutaneous pouches of three beagles for 4 weeks. After harvesting and removing each rod, the excessive fragile tissue connected around the molds was trimmed, and thus tubular autologous connective tissues with the stent were obtained for use as Bio stent grafts (outer diameter, approximately 9.3 mm in all molds). The stent strut was completely surrounded by the dense collagenous membrane (thickness, ∼150 µm). The Bio stent graft luminal surface was extremely flat and smooth. The graft wall of the Bio stent graft possessed an elastic modulus that was almost two times higher than that of the native beagle abdominal aorta. This Bio stent graft is expected to exhibit excellent biocompatibility after being implanted in the aorta, which may reduce the risk of type 1 endoleaks or migration. © 2014 Wiley Periodicals, Inc.

  20. Dialysis catheter-related superior vena cava syndrome with patent vena cava: Long term efficacy of unilateral viatorr stent-graft avoiding catheter manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Quaretti, Pietro; Galli, Franco; Maramarco, Lorenzo Paplo; Corti, Riccardo; Leati, Giovanni; Fiorina, Ilaria; Maestri, Marcello [IRCCS Policlinico San Matteo Foundation, Pavia (Italy)

    2014-06-15

    Central venous catheters are the most frequent causes of benign central vein stenosis. We report the case of a 79-year-old woman on hemodialysis through a twin catheter in the right internal jugular vein, presenting with superior vena cava (SVC) syndrome with patent SVC. The clinically driven endovascular therapy was conducted to treat the venous syndrome with a unilateral left brachiocephalic stent-graft without manipulation of the well-functioning catheter. The follow-up was uneventful until death 94 months later.

  1. Dialysis catheter-related superior vena cava syndrome with patent vena cava: Long term efficacy of unilateral viatorr stent-graft avoiding catheter manipulation

    International Nuclear Information System (INIS)

    Quaretti, Pietro; Galli, Franco; Maramarco, Lorenzo Paplo; Corti, Riccardo; Leati, Giovanni; Fiorina, Ilaria; Maestri, Marcello

    2014-01-01

    Central venous catheters are the most frequent causes of benign central vein stenosis. We report the case of a 79-year-old woman on hemodialysis through a twin catheter in the right internal jugular vein, presenting with superior vena cava (SVC) syndrome with patent SVC. The clinically driven endovascular therapy was conducted to treat the venous syndrome with a unilateral left brachiocephalic stent-graft without manipulation of the well-functioning catheter. The follow-up was uneventful until death 94 months later.

  2. Thrombin Injection Failure with Subsequent Successful Stent-Graft Placement for the Treatment of an Extracranial Internal Carotid Pseudoaneurysm in a 5-Year-Old Child

    International Nuclear Information System (INIS)

    Garcia-Monaco, R. D.; Kohan, A. A.; Martinez-Corvalan, M. P.; Cacchiarelli, N.; Peralta, O.; Wahren, C. G.

    2012-01-01

    Internal carotid artery pseudoaneurysm is a rare life-threatening condition that may develop in different clinical situations. We report the case of an extracranial internal carotid artery pseudoaneurysm secondary to a throat infection in a pediatric patient that was initially treated with percutaneous thrombin injection under ultrasound guidance. However, recanalization occurred at 48 h, and definitive treatment was then performed by endovascular stent-graft placement. We briefly review the clinical characteristics of this uncommon clinical condition as well as the treatment options.

  3. Juxtarenal Modular Aortic Stent Graft Infection Caused by Staphylococcus aureus

    Directory of Open Access Journals (Sweden)

    Róbert Novotný

    2016-01-01

    Full Text Available Introduction. We are presenting a case report of an infected modular abdominal stent graft. Case Presentation. A 67-year-old male patient three years after Cook’s modular abdominal aortic aneurysm (AAA graft implantation for juxtarenal AAA with an implantation of a stent extension into the right common iliac artery for type Ib endoleak. The patient was admitted into our center in severe condition with suspected retroperitoneal bleeding. Computed tomography angiography (CTAG confirmed retroperitoneal bleeding in the right common iliac artery. An urgent surgical revision was indicated; destructed arterial wall around the stent extension in the right common iliac artery was discovered. Due to the severe state of health of the patient, a resection of the infected stent and affected arterial wall was performed, followed by an iliac-femoral crossover bypass. The patient was transported to the intensive care unit with hepatic and renal failure, with maximal catecholamine support. Combined antibiotic treatment was started. The patient died five hours after the procedure. The cause of death was multiorgan failure caused by sepsis. Hemocultures and perioperative microbiological cultures showed the infection agent to be Staphylococcus aureus methicillin sensitive. Conclusion. Stent graft infection is a rare complication. Treatment is associated with high mortality and morbidity.

  4. Percutaneous Stent-Graft Repair of a Mycotic Pulmonary Artery Pseudoaneurysm

    International Nuclear Information System (INIS)

    Chou Meichun; Liang Hueilung; Pan Huayban; Yang Chienfang

    2006-01-01

    Ruptured mycotic pulmonary pseudoaneurysm is a lethal complication. Emergent surgical repair is usually recommended, but still associated with a high mortality rate. We present a patient in whom mycotic pulmonary pseudoaneurysm was a complication after surgical lobectomy 2 weeks earlier. This patient had suffered from repeated massive hemoptysis. After emergent surgical repair of the ruptured pulmonary artery stump, another episode of massive hemorrhage occurred. The pulmonary arteriogram revealed a segmental stenosis and a large, wide-necked, lobulated pseudoaneurysm at the left proximal pulmonary artery. We deployed a balloon-expandable stent-graft (48 mm in length mounted on a 12 mm x 40 mm angioplasty balloon) across the stenotic segment and the neck of the pulmonary pseudoaneurysm. Hemostasis was achieved immediately and, under a 4-week antibiotic treatment, patient was transferred to a local hospital for medical care. This case report demonstrates the benefit of minimally invasive endovascular therapy in a critically ill patient. A literature review of the etiology and management of mycotic pulmonary pseudoaneurysm is included

  5. The implantation of separating aortic stent-graft into the canine thoracic aorta: an experimental study

    International Nuclear Information System (INIS)

    Xia Jinguo; Shi Haibin; Yang Zhengqiang; Li Chao; Liu Sheng; Zu Qingquan; Li Linsun

    2011-01-01

    Objective: to assess the technical feasibility of implanting separating stent-graft into the canine thoracic aorta and to study its biocompatibility. Methods: Twelve adult dogs were randomly and equally divided into three groups. The right femoral artery was cut open, through which the separating stent-graft was inserted and deployed in the canine thoracic aorta, with the proximal end of the graft being quite close to the origin of the left subclavian artery. the technical feasibility of the deployment process was assessed. Angiography was performed at 4, 8 and 12 weeks after stent-graft placement to evaluate the position and patency of the stent-graft. Then the dogs were sacrificed and the specimens were collected for pathologic study. Both gross and microscopic examinations were made to evaluate the fixation of the stent-graft with the vessel wall, the endothelialization of stent-graft surface and the pathologic changes of the vascular wall. Results: A total of ten separating stent-grafts were successfully deployed in the canine thoracic aorta, no migration or deformation occurred. One dog died of massive bleeding due to the rupture of the right femoral artery which occurred when the delivery system containing the inner bare stent was inserted through the right femoral artery. Death occurred in another dog as a result of the ascending aorta rupture caused by the migration of outer-layer stent-graft. Angiography was conducted at 4, 8 and 12 weeks after stent-graft placement. No migration, deformation, rupture or stenosis of the implanted stent-grafts were observed. The formation of intima on the inner surface of the bare stent appeared at 4 weeks, which became more and more obvious with the time passing, and at 12 weeks complete endothelialization of stent-graft surface was observed. Conclusion: Technically, it is feasible to deploy the separating aortic stent-graft into the canine thoracic aorta. Moreover, the separating aortic stent-graft carries excellent

  6. Temporary placement of stent grafts in postsurgical benign biliary strictures: a single center experience.

    Science.gov (United States)

    Vellody, Ranjith; Willatt, Jonathon M; Arabi, Mohammad; Cwikiel, Wojciech B

    2011-01-01

    To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.

  7. Temporary Placement of Stent Grafts in Postsurgical Benign Biliary Strictures: a Single Center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Vellody, Ranjith; Willatt, Jnonathon M.; Arabi, Mohammad; Cwikiel, Wojciech B [Division of Interventional Radiology, University of Michigan, Ann Arbor (United States)

    2011-11-15

    To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.

  8. Temporary Placement of Stent Grafts in Postsurgical Benign Biliary Strictures: a Single Center Experience

    International Nuclear Information System (INIS)

    Vellody, Ranjith; Willatt, Jnonathon M.; Arabi, Mohammad; Cwikiel, Wojciech B

    2011-01-01

    To evaluate the effect of temporary stent graft placement in the treatment of benign anastomotic biliary strictures. Nine patients, five women and four men, 22-64 years old (mean, 47.5 years), with chronic benign biliary anastomotic strictures, refractory to repeated balloon dilations, were treated by prolonged, temporary placement of stent-grafts. Four patients had strictures following a liver transplantation; three of them in bilio-enteric anastomoses and one in a choledocho-choledochostomy. Four of the other five patients had strictures at bilio-enteric anastomoses, which developed after complications following laparoscopic cholecystectomies and in one after a Whipple procedure for duodenal carcinoma. In eight patients, balloon-expandable stent-grafts were placed and one patient was treated by insertion of a self-expanding stent-graft. In the transplant group, treatment of patients with bilio-enteric anastomoses was unsuccessful (mean stent duration, 30 days). The patient treated for stenosis in the choledocho-choledochostomy responded well to consecutive self-expanding stent-graft placement (total placement duration, 112 days). All patients with bilio-enteric anastomoses in the non-transplant group were treated successfully with stent-grafts (mean placement duration, 37 days). Treatment of benign biliary strictures with temporary placement of stent-grafts has a positive effect, but is less successful in patients with strictures developed following a liver transplant.

  9. Endograft Collapse After Endovascular Treatment for Thoracic Aortic Disease

    International Nuclear Information System (INIS)

    Bandorski, Dirk; Brueck, Martin; Guenther, Hans-Ulrich; Manke, Christoph

    2010-01-01

    Endovascular treatment is an established therapy for thoracic aortic disease. Collapse of the endograft is a potentially fatal complication. We reviewed 16 patients with a thoracic endograft between 2001 and 2006. Medical records of the treated patients were studied. Data collected include age, gender, diagnosis, indication for endoluminal treatment, type of endograft, and time of follow up. All patients (n = 16; mean age, 61 years; range, 21-82 years) underwent computed tomography (CT) for location of the lesion and planning of the intervention. Time of follow-up with CT scan ranged from 1 to 61 months. Indications for endovascular treatment were degenerative aneurysm (n = 7; 44%), aortic dissection (n = 2; 12%), perforated aortic ulcer (n = 4; 25%), and traumatic aortic injury (n = 3; 19%). Three patients suffered from a collapse of the endograft (one patient distal, two patients proximal) between 3 and 8 days after endovascular treatment. These patients were younger (mean age, 37 ± 25 years vs. 67 ± 16 years; P 0.05]; distal, 45 ± 23.5% vs. 38 ± 21.7% [P > 0.05]). Proximal collapse was corrected by placing a bare stent. In conclusion, risk factors for stent-graft collapse are a small lumen of the aorta and a small radius of the aortic arch curvature (young patients), as well as oversizing, which is an important risk factor and is described for different types of endografts and protheses (Gore TAG and Cook Zenith). Dilatation of the collapsed stent-graft is not sufficient. Following therapy implantation of a second stent or surgery is necessary in patients with a proximal endograft collapse. Distal endograft collapse can possibly be treated conservatively under close follow-up.

  10. Acute Iliac Artery Rupture: Endovascular Treatment

    International Nuclear Information System (INIS)

    Chatziioannou, A.; Mourikis, D.; Katsimilis, J.; Skiadas, V.; Koutoulidis, V.; Katsenis, K.; Vlahos, L.

    2007-01-01

    The authors present 7 patients who suffered iliac artery rupture over a 2 year period. In 5 patients, the rupture was iatrogenic: 4 cases were secondary to balloon angioplasty for iliac artery stenosis and 1 occurred during coronary angioplasty. In the last 2 patients, the rupture was secondary to iliac artery mycotic aneurysm. Direct placement of a stent-graft was performed in all cases, which was dilated until extravasation was controlled. Placement of the stent-graft was successful in all the cases, without any complications. The techniques used, results, and mid-term follow-up are presented. In conclusion, endovascular placement of a stent-graft is a quick, minimally invasive, efficient, and safe method for emergency treatment of acute iliac artery rupture, with satisfactory short- and mid-term results

  11. Endovascular surgery in Marfan syndrome: CON.

    Science.gov (United States)

    Kouchoukos, Nicholas T

    2017-11-01

    The frequency of endovascular stent grafting procedures to treat various conditions of the thoracic aorta has increased dramatically over the past three decades. Stent grafting has been applied on a limited basis in patients with Marfan syndrome and other connective tissue disorders, despite recommendations from current guidelines and expert consensus statements against its use in this setting. A review of publications reporting outcomes after stent grafting of the descending thoracic aorta in Marfan patients with acute or chronic aortic dissection indicates that these procedures can be accomplished with rates of early mortality, stroke and spinal cord ischemic injury that are comparable to those observed in patients who do not have Marfan syndrome. However, the rates of primary treatment failure (principally endoleak), secondary treatment failure, need for open repair and late death among the Marfan patients are substantially higher than those observed in patients without this condition. In addition, the rates of retrograde aortic dissection and development of stent-graft induced new entry (SINE), are also greater among patients with Marfan syndrome. All of these findings argue strongly against the routine use of endovascular grafts in Marfan patients with type B or residual type A dissection. Few data are available to assess the role of endografting in Marfan patients with aneurysmal disease, but the progressive aortic dilatation noted in these patients argues strongly against its use in this setting as well. At present, the available data indicate that there is no justification for elective stent grafting in Marfan patients with aortic dissection or aneurysm. The only reasonable indications for primary aortic stent grafting are in the setting of acute aortic dissection or rupture, where the intervention is considered life-saving and rarely, considering the relatively young age of these patients, where the risk of open operation is considered to be prohibitive.

  12. Late Complication after Superficial Femoral Artery (SFA) Aneurysm: Stent-graft Expulsion Outside the Skin

    Energy Technology Data Exchange (ETDEWEB)

    Pecoraro, Felice, E-mail: felicepecoraro@libero.it; Sabatino, Ermanno R.; Dinoto, Ettore; Rosa, Giuliana La; Corte, Giuseppe; Bajardi, Guido [University of Palermo, Vascular Surgery Unit (Italy)

    2015-10-15

    A 78-year-old man presented with a 7-cm aneurysm in the left superficial femoral artery, which was considered unfit and anatomically unsuitable for conventional open surgery for multiple comorbidities. The patient was treated with stent-graft [Viabhan stent-graft (WL Gore and Associates, Flagstaff, AZ)]. Two years from stent-graft implantation, the patient presented a purulent secretion and a spontaneous external expulsion through a fistulous channel. No claudication symptoms or hemorrhagic signs were present. The pus and device cultures were positive for Staphylococcus aureus sensitive to piperacillin/tazobactam. Patient management consisted of fistula drainage, systemic antibiotic therapy, and daily wound dressing. At 1-month follow-up, the wound was closed. To our knowledge, this is the first case of this type of stent-graft complication presenting with external expulsion.

  13. Treatment of Portosystemic Shunt Myelopathy with a Stent Graft Deployed through a Transjugular Intrahepatic Route

    International Nuclear Information System (INIS)

    Jain, Deepak; Arora, Ankur; Deka, Pranjal; Mukund, Amar; Bhatnagar, Shorav; Jindal, Deepti; Kumar, Niteen; Pamecha, Viniyendra

    2013-01-01

    A case of surgically created splenorenal shunt complicated with shunt myelopathy was successfully managed by placement of a stent graft within the splenic vein to close the portosystemic shunt and alleviate myelopathy. To our knowledge, this is the first report of a case of shunt myelopathy in a patient with noncirrhotic portal fibrosis without cirrhosis treated by a novel technique wherein a transjugular intrahepatic route was adopted to deploy the stent graft

  14. Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts in the treatment of acute malignant colorectal obstruction.

    Science.gov (United States)

    Kim, Honsoul; Kim, Seung Hyoung; Choi, Sun Young; Lee, Kwang-Hun; Won, Jong Yoon; Lee, Do Yun; Lee, Jong Tae

    2008-12-01

    To evaluate the technical feasibility and clinical effectiveness of fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for acute malignant colorectal obstruction. Radiologic images and clinical reports of 42 patients (22 men, 20 women; age range, 28-93 years; median age, 65.5 years) who underwent fluoroscopically guided colorectal stent insertion without endoscopic assistance for acute malignant obstruction were reviewed retrospectively. Eighteen patients received bare stents as a bridge to surgery. Twenty-four patients received 27 insertions of either a bare stent (n = 15) or a stent-graft (n = 12) for palliation. The obstruction was located in the rectum (n = 8), sigmoid (n = 17), descending colon (n = 8), splenic flexure (n = 3), and transverse colon (n = 6). Clinical success, defined as more than 50% dilatation of the stent with subsequent symptomatic improvement, was achieved in 41 of the 42 patients (98%). No major procedure-related complications occurred. Minor complications occurred in eight of the 45 procedures (18%). No perioperative mortalities occurred within 1 month after surgery. In the palliative group, the median stent patency was 62 days (range, 0-1,014 days). There was no statistically significant difference in stent patency between the bare stents (range, 0-855 days; median, 68 days) and stent-grafts (range, 1-1,014 days; median, 81 days). Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for the relief of acute malignant colorectal obstruction was technically feasible without endoscopic assistance-even in lesions proximal to the splenic flexure and transverse colon-and clinically effective in both bridge to surgery and palliative management.

  15. Multidetector-Row Computed Tomography in the Evaluation of Transjugular Intrahepatic Portosystemic Shunt Performed with Expanded-Polytetrafluoroethylene-Covered Stent-Graft

    International Nuclear Information System (INIS)

    Fanelli, Fabrizio; Bezzi, Mario; Bruni, Antonio; Corona, Mario; Boatta, Emanuele; Lucatelli, Pierleone; Passariello, Roberto

    2011-01-01

    We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound–color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findings and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.

  16. Evaluation of fluency stent-grafts in transjugular intrahepatic portosystemic shunts

    International Nuclear Information System (INIS)

    Zhao Jianbo; Li Yanhao; Chen Yong; He Xiaofeng; Zeng Qingle; Mei Quelin; Lu Wei

    2009-01-01

    Objective: To evaluate the efficacy of Fluency stent-graft (Bard Corp) in transjugular intrahepatic portosystemic shunt (TIPS). Methods: The clinical data of 21 consecutive patients treated by TIPS using Fluency stent-grafts were retrospectively reviewed. All of them were recurrent variceal bleeding secondary to portal vein hypertension, 1 was bleeding secondary to primary hepatic carcinoma with port vein thrombus, and 1 was Budd-Chiari syndrome. They were followed-up after (10.1±4.6) months (2.0 to 24.0 months). Stent-grafts patancy, portal vein pressure and liver function were recorded and compared. Results: Twenty-five stent-grafts were successfully implanted in 21 patients, 23 stent grafts were 8 mm 2 were 10 mm in diameter. The covered length of the stents varied from 6 to 8 cm. The bleeding was stopped and the portal vein pressure decreased significantly from (25.4±3.5) mm Hg to (15.4±2.8) mm Hg (t= 12.495, P 0.05). Conclusion: The Fluency stent-grafts could increase the patency of the TIPS, but its efficacy on the long-term effect and hepatic encephalopathy need further investigation. (authors)

  17. Are TIPS Stent-Grafts a Contraindication for Future Liver Transplantation?

    International Nuclear Information System (INIS)

    Maleux, Geert; Pirenne, Jacques; Vaninbroukx, Johan; Aerts, Raymond; Nevens, Frederik

    2004-01-01

    Our purpose was to assess the feasibility of orthotopic liver transplantation (OLT) in patients priorly having undergone transjugular intrahepatic portosystemic shunt (TIPS) with an expanded tetrafluoroethylene (e-PTFE)-covered endoprosthesis. In 48 patients an e- PTFE-covered endoprosthesis was inserted to treat severe complications of portal hypertension. In 36 patients the endoprosthesis was inserted during TIPS creation (de novo TIPS); in the other 12 patients the endoprosthesis was placed to repermeabilize the previously created, but occluded bare stent (revision TIPS). Eight of them (5 de novo and 3 revision cases) later underwent an OLT. The hospital records of these patients were reviewed from initial admission, through TIPS, the pre-OLT period, and OLT to current postoperative status. Five de novo and 3 revision cases underwent OLT 4-279 days (mean delay: 80.8 days) after TIPS procedure. All OLT's were performed under veno-venous bypass surgery. De visu surgical inspection confirmed correct positioning of the fully patent stent graft, starting in the portal vein and ending at the junction of the hepatic vein to the inferior caval vein. No surgical difficulty was observed during proximal or distal clamping or during resection of the diseased liver. Correctly positioned e-PTFE-covered nitinol endoprostheses do not interfere with a later OLT and may not be considered as a contraindication in patients who need a TIPS as a bridge to OLT

  18. Retrograde type A dissection following hybrid supra-aortic endovascular surgery in high-risk patients unfit for conventional open repair.

    Science.gov (United States)

    Yip, Hon C; Chan, Yiu C; Qing, Kai X; Cheng, Stephen W

    2018-04-01

    Hybrid procedures with combined open extra-anatomical supra-aortic bypasses and endovascular surgery are less invasive for patients with complex aortic arch pathology. The aim of this paper is to report patients who developed retrograde type A aortic dissection following initially successful hybrid endovascular treatment. Retrospective review of prospectively collected computerized departmental database. All patients with supra-aortic hybrid endovascular surgery and post-procedure retrograde type A dissection were identified. Patient demographics, comorbid conditions, perioperative parameters, procedural details and post-operative complications were collected. From May 2005 to July 2014, 163 patients underwent thoracic aortic endovascular procedures at our institution. From the 46 patients who had supra-aortic hybrid endovascular repair, six patients (6/46, 13% of all supra-aortic hybrid cases, 3 males) developed retrograde type A aortic dissection. All were elective cases, with 3 chronic dissecting aneurysms and 3 atherosclerotic aneurysms. All had one-stage hybrid procedures: 2 patients had carotid-carotid bypass grafts, one had carotid-carotid-left subclavian bypass graft, and 3 had bypass grafts from ascending aorta to innominate artery and left carotid artery. Five patients had Cook Zenith thoracic stent-grafts (Cook Medical, Bloomington, IN, USA), and one had Medtronic Valiant stent-grafts (Medtronic Vascular Inc, Santa Rosa, CA, USA). The retrograde type A dissection occurred with sudden symptoms at day 5, 6, 10, 20, 105 and 128, respectively. There were 3 immediate fatalities and 2 patients treated conservatively deemed unfit for reintervention (one died of pneumonia at 9 months, and one remained alive at 7 months post-complication). One patient underwent successful emergency open surgery and survived. Supra-aortic hybrid procedures in treating aortic arch pathology may be at risk of developing retrograde type A dissection. This post-operative complication

  19. A Novel Attempt to Standardize Results of CFD Simulations Basing on Spatial Configuration of Aortic Stent-Grafts.

    Directory of Open Access Journals (Sweden)

    Andrzej Polanczyk

    Full Text Available Currently, studies connected with Computational Fluid Dynamic (CFD techniques focus on assessing hemodynamic of blood flow in vessels in different conditions e.g. after stent-graft's placement. The paper propose a novel method of standardization of results obtained from calculations of stent-grafts' "pushing forces" (cumulative WSS--Wall Shear Stress, and describes its usefulness in diagnostic process. AngioCT data from 27 patients were used to reconstruct 3D geometries of stent-grafts which next were used to create respective reference cylinders. We made an assumption that both the side surface and the height of a stent-graft and a reference cylinder were equal. The proposed algorithm in conjunction with a stent-graft "pushing forces" on an implant wall, allowed us to determine which spatial configuration of a stent-graft predispose to the higher risk of its migration. For stent-grafts close to cylindrical shape (shape factor φ close to 1 WSS value was about 267 Pa, while for stent-grafts different from cylindrical shape (φ close to 2 WSS value was about 635 Pa. It was also noticed that deformation in the stent-graft's bifurcation part impaired blood flow hemodynamic. Concluding the proposed algorithm of standardization proved its usefulness in estimating the WSS values that may be useful in diagnostic process. Angular bends or tortuosity in bifurcations of an aortic implant should be considered in further studies of estimation of the risk of implantation failure.

  20. Early and long-term clinical and radiological follow-up results of expanded-polytetrafluoroethylene-covered stent-grafts for transjugular intrahepatic portosystemic shunt procedures

    International Nuclear Information System (INIS)

    Maleux, Geert; Heye, Sam; Thijs, Maria; Wilms, Guy; Nevens, Frederik; Verslype, Chris; Wilmer, Alexander

    2004-01-01

    The purpose of this study was to assess the therapeutic efficacy and immediate and long-term safety of expanded-tetrafluoroethylene covered stent-grafts for transjugular intrahepatic portosystemic shunts in patients with portal hypertension-related complications. A cohort of 56 patients suffering from severe portal hypertension-related complications underwent implantation of an expanded-polytetrafluoroethylene-covered stent-graft. All patients suffered from severe liver cirrhosis graded Child-Pugh A (n=8; 16%), B (n=13; 21%) or C (n=35; 63%). In 44 patients, the stent-graft was placed during the initial TIPS procedure (de novo TIPS); in the other 12 patients, the stent-graft was placed to repermeabilize the previously placed bare stent (TIPS revision). Follow-up was performed with clinical assessment, duplex ultrasound and, if abnormal or inconclusive, with invasive venography and pressure measurements. Per- en immediate post-procedural complications occurred in four patients (4/56, 7%). None of them was lethal. During follow-up, stent occlusion appeared in one patient and stenosis in two; no recurrence of bleeding was noted in all patients treated for variceal bleeding (n=28), and 24 of the 28 patients (86%) suffering from refractory ascites and/or hepatic hydrothorax were free of regular paracenteses and/or drainage of pleural effusion after shunt creation. The 30-day and global mortality for the total study population (n=56) was, respectively, 7% (n=4) and 28.5% (n=16). In the patient subgroup with variceal bleeding (n=28), 30-day mortality was 3.5% (n=1) and global mortality 14.2% (n=4). In the ascites and/or hydrothorax subgroup (n=28), 8.1% (n=3) mortality at 30 days was found and global mortality was 32.4% (n=12). In 10 patients of the 56 studied patients (18%), isolated hepatic encephalopathy occurred, which was lethal in 4 (Child C) patients (7%). Three of these four patients died within the 1st month after TIPS placement. A very high primary patency rate

  1. Early and long-term clinical and radiological follow-up results of expanded-polytetrafluoroethylene-covered stent-grafts for transjugular intrahepatic portosystemic shunt procedures

    Energy Technology Data Exchange (ETDEWEB)

    Maleux, Geert; Heye, Sam; Thijs, Maria; Wilms, Guy [University Hospitals Gasthuisberg, Department of Radiology, Leuven (Belgium); Nevens, Frederik; Verslype, Chris [University Hospitals Gasthuisberg, Department of Hepatology, Leuven (Belgium); Wilmer, Alexander [University Hospitals Gasthuisberg, Department of Medical Intensive Care Unit, Leuven (Belgium)

    2004-10-01

    The purpose of this study was to assess the therapeutic efficacy and immediate and long-term safety of expanded-tetrafluoroethylene covered stent-grafts for transjugular intrahepatic portosystemic shunts in patients with portal hypertension-related complications. A cohort of 56 patients suffering from severe portal hypertension-related complications underwent implantation of an expanded-polytetrafluoroethylene-covered stent-graft. All patients suffered from severe liver cirrhosis graded Child-Pugh A (n=8; 16%), B (n=13; 21%) or C (n=35; 63%). In 44 patients, the stent-graft was placed during the initial TIPS procedure (de novo TIPS); in the other 12 patients, the stent-graft was placed to repermeabilize the previously placed bare stent (TIPS revision). Follow-up was performed with clinical assessment, duplex ultrasound and, if abnormal or inconclusive, with invasive venography and pressure measurements. Per- en immediate post-procedural complications occurred in four patients (4/56, 7%). None of them was lethal. During follow-up, stent occlusion appeared in one patient and stenosis in two; no recurrence of bleeding was noted in all patients treated for variceal bleeding (n=28), and 24 of the 28 patients (86%) suffering from refractory ascites and/or hepatic hydrothorax were free of regular paracenteses and/or drainage of pleural effusion after shunt creation. The 30-day and global mortality for the total study population (n=56) was, respectively, 7% (n=4) and 28.5% (n=16). In the patient subgroup with variceal bleeding (n=28), 30-day mortality was 3.5% (n=1) and global mortality 14.2% (n=4). In the ascites and/or hydrothorax subgroup (n=28), 8.1% (n=3) mortality at 30 days was found and global mortality was 32.4% (n=12). In 10 patients of the 56 studied patients (18%), isolated hepatic encephalopathy occurred, which was lethal in 4 (Child C) patients (7%). Three of these four patients died within the 1st month after TIPS placement. A very high primary patency rate

  2. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    Energy Technology Data Exchange (ETDEWEB)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua [University Hospital, University of Cologne, Department of Radiology, Cologne (Germany); Pfister, Roman [University Hospital, University of Cologne, Department of Internal Medicine III, Cologne (Germany); Deppe, Antje-Christin [University Hospital, University of Cologne, Department of Cardiothoracic Surgery, Cologne (Germany); Matoussevitch, Vladimir [University Hospital, University of Cologne, Department of Vascular Surgery, Cologne (Germany)

    2014-06-15

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  3. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    International Nuclear Information System (INIS)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua; Pfister, Roman; Deppe, Antje-Christin; Matoussevitch, Vladimir

    2014-01-01

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  4. Balloon-Expandable Stent Graft for Treating Uretero-Iliac Artery Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Guntau, Moritz, E-mail: guntau@med.uni-marburg.de [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hegele, Axel [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Rheinheimer, Stephan [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hofmann, Rainer [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Mahnken, Andreas H. [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany)

    2017-06-15

    PurposeTo evaluate the safety, efficacy and outcome of percutaneous balloon-expandable covered stent graft placement for uretero-iliac artery fistula (UAF) treatment.MethodsThis retrospective study evaluated the single-center experience of percutaneous balloon-expandable covered stent graft placement (ADVANTA™, Atrium Hudson, NH, USA) in UAF. Data were obtained from a prospective institutional database. Patient follow-up included complications, symptoms recurrence and mortality rate.ResultsTen UAFs in eight patients (3 males; 5 females) with a mean age of 64.5 (35–77) years were identified. All patients had a history pelvic malignancy, extirpative surgery (n = 6), long-term ureteral stenting (n = 7) and pelvic radiation (n = 5). All procedures were completed successfully without complications. Thirty-day mortality rate was zero. At a median follow-up of 6 (1–60) months, one patient suffered recurrent hematuria requiring a secondary stent graft placement 26 months after the initial treatment. During follow-up, five patients died of the underlying disease (43, 66, 105, and 183 and 274 days after the last procedure).ConclusionPercutaneous balloon-expandable stent graft placement in UAF is a safe and effective treatment option. Implantation of stent grafts should be considered as treatment of choice in UAF.

  5. Ischaemia of the medullary cone after stent-graft implantation in a patient with abdominal aortic aneurysm - a case study.

    Science.gov (United States)

    Wachowski, Mariusz; Polguj, Michał; Ścibór, Janusz; Majos, Agata

    2018-03-01

    Preoperative visualization of the Adamkiewicz artery - the vessel which is to a great extent responsible for supplying blood to the medullary cone - is an important step which must be taken before initiating restorative procedures in the aorta. We present a case of a 67-year-old patient who underwent an intravascular stent-graft implantation procedure, due to clinical signs of abdominal aortic aneurysm. Routine pre-operative computed tomography examination failed to demonstrate the Adamkiewicz artery. On the second day after the surgery, as a result of unexpected clinical deterioration, an magnetic resonance imaging examination of the lumbar spine was carried out. Based on the magnetic resonance imaging images and clinical manifestations the diagnosis of ischaemia of the medullary cone was made. In our work we also present a deep analysis of the anatomy of small-sized vessels supplying blood to the spinal cord and discuss effective techniques which enable visualization of the Adamkiewicz artery.

  6. Use of a Stent Graft for Bleeding Hepatic Artery Pseudoaneurysm Following Pancreaticoduodenectomy

    Directory of Open Access Journals (Sweden)

    Leoncio L. Kaw, Jr

    2006-10-01

    Full Text Available Although uncommon, bleeding following pancreaticoduodenectomy is associated with high mortality. Management generally includes surgical reexploration or, alternatively, transarterial embolization. We report the case of a 62-year-old man who presented with massive upper gastrointestinal bleeding 3 weeks after pancreaticoduodenectomy. Selective coeliac angiography revealed a large pseudoaneurysm involving the proper hepatic artery. This was treated successfully with a stent graft. There was no recurrence of bleeding at the 6-month follow-up. To our knowledge, this is the first report of stent graft repair of bleeding hepatic artery pseudoaneurysm following pancreaticoduodenectomy.

  7. Endovascular Exclusion of Renal Artery Aneurysm

    International Nuclear Information System (INIS)

    Andersen, Poul Erik; Rohr, Nils

    2005-01-01

    A patient who was operated for an abdominal aortic aneurysm 7 years earlier presented with recently discovered iliac and renal artery aneurysms. The renal artery had an angulation of 90 o , but the aneurysm was successfully excluded using a covered vascular stent graft placed over an extrastiff guidewire. Even in cases of complex anatomy of a renal aneurysm, endovascular treatment should be considered. With development of more flexible and low-profile endoprosthesis with accurate deployment, these have become more usable

  8. Emergency Stent Grafting After Unsuccessful Surgical Repair of a Mycotic Common Femoral Artery Pseudoaneurysm in a Drug Abuser

    International Nuclear Information System (INIS)

    Lupattelli, Tommaso; Garaci, Francesco Giuseppe; Basile, Antonio; Minnella, Daniela Paola; Casini, Andrea; Clerissi, Jacques

    2009-01-01

    Mycotic false aneurysm caused by local arterial injury from attempted intravenous injections in drug addicts remains a challenging clinical problem. The continued increase in drug abuse has resulted in an increased incidence of this problem, particularly in high-volume urban centres. In the drug-abusing population, mycotic arterial pseudoaneurysms most often occur because of missed venous injection and are typically seen in the groin, axilla, and antecubital fossa. Mycotic aneurysms may lead to life-threatening haemorrhage, limb loss, sepsis, and even death. Any soft-tissue swelling in the vicinity of a major artery in an intravenous drug abuser should be suspected of being a false aneurysm until proven otherwise and should prompt immediate referral to a vascular surgeon for investigation and management. We report a case of rupturing mycotic pseudoaneurysm of the left common femoral artery treated by surgical resection followed by vessel reconstruction with autologous material. Unfortunately, at the time of discharge a sudden leakage from the vein graft anastomosis occurred, with subsequent massive bleeding, and required emergent endovascular covered stenting. To the best of our knowledge, this is the first reported case of femoral artery bleeding in a drug abuser treated by stent graft placement.

  9. Left subclavian artery revascularization as part of thoracic stent grafting

    NARCIS (Netherlands)

    Saouti, N.; Hindori, V.; Morshuis, W.J.; Heijmen, R.H.

    2015-01-01

    OBJECTIVES: Intentional covering of the left subclavian artery (LSA) as part of thoracic endovascular aortic repair (TEVAR) can cause (posterior) strokes or left arm malperfusion. LSA revascularization can be done as prophylaxis against, or as treatment of, these complications. We report our

  10. Uncommon Case of a Post-Traumatic Portal Vein Pseudoaneurysm Treated with Percutaneous Transhepatic Stent Grafting

    Energy Technology Data Exchange (ETDEWEB)

    Ierardi, Anna Maria, E-mail: amierardi@yahoo.it [Uninsubria, Ospedale di Circolo, Interventional Radiology Unit (Italy); Berselli, Mattia, E-mail: mattia.berselli@ospedale.varese.it [Uninsubria, Ospedale di Circolo, Department of Surgery (Italy); Cuffari, Salvatore, E-mail: salvatore.cuffari@ospedale.varese.it [Uninsubria, Ospedale di Circolo, Anesthesiology Department (Italy); Castelli, Patrizio, E-mail: patrizio.castelli@uninsubria.it [Uninsubria, Ospedale di Circolo, Department of Vascular Surgery (Italy); Cocozza, Eugenio, E-mail: eugenio.cocozza@ospedale.varese.it [Uninsubria, Ospedale di Circolo, Department of Surgery (Italy); Carrafiello, Gianpaolo, E-mail: gcarraf@gmail.com [Uninsubria, Ospedale di Circolo, Interventional Radiology Unit (Italy)

    2016-10-15

    We describe a man who presented with a traumatic portal vein pseudoaneurysm, which was subsequently managed with a percutaneous transhepatic stent graft. This case demonstrates a rarely seen condition in the traumatic population and a novel management strategy, which should be considered in the management of this challenging injury.

  11. Cephalic Arch Stenosis in Autogenous Haemodialysis Fistulas: Treatment With the Viabahn Stent-Graft

    Energy Technology Data Exchange (ETDEWEB)

    Shawyer, Andrew, E-mail: andrew.shawyer@bartsandthelondon.nhs.uk [The Royal London Hospital, Radiology Department (United Kingdom); Fotiadis, Nicos I., E-mail: fotiadis.nicholas@gmail.com [Royal Marsden Hospital, Radiology Department, The Royal Marsden NHS Foundation Trust (United Kingdom); Namagondlu, Girish, E-mail: girish.namagondlu@bartsandthelondon.nhs.uk [The Royal London Hospital, Renal Medicine Department (United Kingdom); Iyer, Arun, E-mail: arun.iyer@bartsandthelondon.nhs.uk [The Royal London Hospital, Radiology Department (United Kingdom); Blunden, Mark, E-mail: mark.blunden@bartsandthelondon.nhs.uk; Raftery, Martin, E-mail: martin.raftery@bartsandthelondon.nhs.uk; Yaqoob, Magdi, E-mail: magdi.yaqoob@bartsandthelondon.nhs.uk [The Royal London Hospital, Renal Medicine Department (United Kingdom)

    2013-02-15

    Cephalic arch stenosis (CAS) is an important and common cause of dysfunction in autogenous haemodialysis fistulas that requires multiple reinterventions and aggressive surveillance. We evaluated the safety and efficacy of the Viabahn stent-graft for the management of CAS. Between April 2005 and October 2011, 11 consecutive patients [four men and seven women (mean age 56.7 years)] with CAS and dysfunctional fistulas were treated with insertion of 11 Viabahn stent-grafts. Six stent-grafts were inserted due to residual stenosis after angioplasty and five for fistuloplasty-induced rupture. No patient was lost to follow-up. The technical and clinical success rate was 100 %. Primary access patency rates were 81.8 % [95 % confidence interval (CI) 0.482-0.977] at 6 months and 72.7 % (95 % CI 0.390-0.939) at 12 months. Secondary access patency rates were 90.9 % at 6 months (95 % CI 0.587-0.997). There were no procedure-related complications. Mean follow-up was 543.8 days (range 156-2,282). The use of the Viabahn stent-graft in the management of CAS is technically feasible and, in this small series, showed patency rates that compare favorably with historical data of angioplasty and bare stents.

  12. Cephalic Arch Stenosis in Autogenous Haemodialysis Fistulas: Treatment With the Viabahn Stent-Graft

    International Nuclear Information System (INIS)

    Shawyer, Andrew; Fotiadis, Nicos I.; Namagondlu, Girish; Iyer, Arun; Blunden, Mark; Raftery, Martin; Yaqoob, Magdi

    2013-01-01

    Cephalic arch stenosis (CAS) is an important and common cause of dysfunction in autogenous haemodialysis fistulas that requires multiple reinterventions and aggressive surveillance. We evaluated the safety and efficacy of the Viabahn stent-graft for the management of CAS. Between April 2005 and October 2011, 11 consecutive patients [four men and seven women (mean age 56.7 years)] with CAS and dysfunctional fistulas were treated with insertion of 11 Viabahn stent-grafts. Six stent-grafts were inserted due to residual stenosis after angioplasty and five for fistuloplasty-induced rupture. No patient was lost to follow-up. The technical and clinical success rate was 100 %. Primary access patency rates were 81.8 % [95 % confidence interval (CI) 0.482–0.977] at 6 months and 72.7 % (95 % CI 0.390–0.939) at 12 months. Secondary access patency rates were 90.9 % at 6 months (95 % CI 0.587–0.997). There were no procedure-related complications. Mean follow-up was 543.8 days (range 156–2,282). The use of the Viabahn stent-graft in the management of CAS is technically feasible and, in this small series, showed patency rates that compare favorably with historical data of angioplasty and bare stents.

  13. Computational Fluid Dynamics: Hemodynamic Changes in Abdominal Aortic Aneurysm After Stent-Graft Implantation

    International Nuclear Information System (INIS)

    Frauenfelder, Thomas; Lotfey, Mourad; Boehm, Thomas; Wildermuth, Simon

    2006-01-01

    The aim of this study was to demonstrate quantitatively and qualitatively the hemodynamic changes in abdominal aortic aneurysms (AAA) after stent-graft placement based on multidetector CT angiography (MDCT-A) datasets using the possibilities of computational fluid dynamics (CFD). Eleven patients with AAA and one patient with left-side common iliac aneurysm undergoing MDCT-A before and after stent-graft implantation were included. Based on the CT datasets, three-dimensional grid-based models of AAA were built. The minimal size of tetrahedrons was determined for grid-independence simulation. The CFD program was validated by comparing the calculated flow with an experimentally generated flow in an identical, anatomically correct silicon model of an AAA. Based on the results, pulsatile flow was simulated. A laminar, incompressible flow-based inlet condition, zero traction-force outlet boundary, and a no-slip wall boundary condition was applied. The measured flow volume and visualized flow pattern, wall pressure, and wall shear stress before and after stent-graft implantation were compared. The experimentally and numerically generated streamlines are highly congruent. After stenting, the simulation shows a reduction of wall pressure and wall shear stress and a more equal flow through both external iliac arteries after stenting. The postimplantation flow pattern is characterized by a reduction of turbulences. New areas of high pressure and shear stress appear at the stent bifurcation and docking area. CFD is a versatile and noninvasive tool to demonstrate changes of flow rate and flow pattern caused by stent-graft implantation. The desired effect and possible complications of a stent-graft implantation can be visualized. CFD is a highly promising technique and improves our understanding of the local structural and fluid dynamic conditions for abdominal aortic stent placement

  14. Vascular Biocompatibility of a Triple Layered Self Expanding Stent-Graft in a Dog Mode

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jae Ik; Won, Je Hwan; Jang, Eun Ho; Lee, Sung Yeong; Ko, Kwang Tae [Dept. of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Jin, Bo Hwan [Medical Science Research Center, Ajou University School of Medicine, Suwon (Korea, Republic of); Lee, June Woo [Dept. of Radiology, Busan National University College of Medicine, Busan (Korea, Republic of)

    2012-02-15

    To evaluate performance and biocompatibility of a newly designed self-expanding stent graft, which consisted of two nitinol stents and an intervening expanded polytetrafluoroethylene membrane in a dog artery model. Twelve stent grafts were placed in the aorta of 6 dogs (beagle, mean body weight 11 kg) for 4 weeks (n = 4) and 12 weeks (n = 8). Luminal diameters were measured for each segment (the proximal bare, the middle graft, the distal bare) by angiographies after implantation and follow up periods. Percent luminal stenosis based on angiographies, histomorphometric, histologic, and scanning electron microscopic analyses of each segments were performed. Blood flow through the stent grafts was good after implantation and during the follow up period, without thrombotic occlusion or stent graft migration. The mean percent luminal stenosis of the proximal bare, the middle grafted and the distal bare segments after 12 weeks were 13.5%, 3.9%, 9.6% retrospectively. The mean neointimal areas of the middle grafted segment were 4.39 mm{sup 2} (4 week) and 4.92 mm{sup 2} (12 week). Mature endothelialization was evident in over 70% of the area of the stented artery after 4 weeks and in over 90% after 12 weeks. The stent graft was well placed in the attempted area without migration. During the 12-week-follow up period, it showed a good patency without thrombotic occlusion or significant in-stent luminal stenosis. Endothelialization was rapid and nearly complete. Neointima was thin and smooth on the middle graft segment and thicker and irregular on the bare segments.

  15. Vascular Biocompatibility of a Triple Layered Self Expanding Stent-Graft in a Dog Mode

    International Nuclear Information System (INIS)

    Bae, Jae Ik; Won, Je Hwan; Jang, Eun Ho; Lee, Sung Yeong; Ko, Kwang Tae; Jin, Bo Hwan; Lee, June Woo

    2012-01-01

    To evaluate performance and biocompatibility of a newly designed self-expanding stent graft, which consisted of two nitinol stents and an intervening expanded polytetrafluoroethylene membrane in a dog artery model. Twelve stent grafts were placed in the aorta of 6 dogs (beagle, mean body weight 11 kg) for 4 weeks (n = 4) and 12 weeks (n = 8). Luminal diameters were measured for each segment (the proximal bare, the middle graft, the distal bare) by angiographies after implantation and follow up periods. Percent luminal stenosis based on angiographies, histomorphometric, histologic, and scanning electron microscopic analyses of each segments were performed. Blood flow through the stent grafts was good after implantation and during the follow up period, without thrombotic occlusion or stent graft migration. The mean percent luminal stenosis of the proximal bare, the middle grafted and the distal bare segments after 12 weeks were 13.5%, 3.9%, 9.6% retrospectively. The mean neointimal areas of the middle grafted segment were 4.39 mm 2 (4 week) and 4.92 mm 2 (12 week). Mature endothelialization was evident in over 70% of the area of the stented artery after 4 weeks and in over 90% after 12 weeks. The stent graft was well placed in the attempted area without migration. During the 12-week-follow up period, it showed a good patency without thrombotic occlusion or significant in-stent luminal stenosis. Endothelialization was rapid and nearly complete. Neointima was thin and smooth on the middle graft segment and thicker and irregular on the bare segments.

  16. Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

    International Nuclear Information System (INIS)

    Saha, Prakash; Hughes, John; Patel, Ashish S.; Donati, Tommaso; Sallam, Morad; Patel, Sanjay D.; Bell, Rachel E.; Katsanos, Konstantinos; Modarai, Bijan; Zayed, Hany A.

    2015-01-01

    PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities

  17. Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Prakash, E-mail: prakash.2.saha@kcl.ac.uk; Hughes, John, E-mail: johnhughes387@rocketmail.com; Patel, Ashish S., E-mail: ashish.s.patel@kcl.ac.uk; Donati, Tommaso, E-mail: tommaso.donati@gstt.nhs.uk; Sallam, Morad, E-mail: morad.sallam@gstt.nhs.uk; Patel, Sanjay D., E-mail: sanjay.patel@gstt.nhs.uk; Bell, Rachel E. [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Modarai, Bijan, E-mail: bijan.modarai@kcl.ac.uk; Zayed, Hany A., E-mail: hany.zayed@gstt.nhs.uk [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)

    2015-08-15

    PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities.

  18. Surgical treatment and thoracic endovascular aortic repair in type A aortic dissection in a pregnant patient with Marfan syndrome.

    Science.gov (United States)

    Sterner, Doerthe; Probst, Chris; Mellert, Friedrich; Schiller, Wolfgang

    2014-07-01

    We report an acute aortic dissection type Stanford A extending down to both iliac arteries affecting a 32-year-old woman suspected to have Marfan syndrome during week 37 of pregnancy. In a multidisciplinary approach, and emergency Cesarean section was performed followed by an abdominal hysterectomy and a valve-sparing aortic root replacement using a reimplantation technique. The aorta was replaced up to the hemi arch. Because of the high suspicion of visceral ischemia as confirmed ex juvantibus, an endovascular stent graft was implanted. Molecular testing revealed a frameshift mutation and confirmed the diagnosis of Marfan syndrome. Both the patient and her healthy child underwent an uneventful recovery. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Application of rapid artificial cardiac pacing in thoracic endovascular aortic repair in aged patients

    Directory of Open Access Journals (Sweden)

    Chen J

    2013-12-01

    Full Text Available Jun Chen,1,* Wenhui Huang,2,* Songyuan Luo,2,* Dahao Yang,1 Zhengrong Xu,1 Jianfang Luo21Department of Angiocardiopathy, Affiliated Baoan Hospital of Southern Medical University, Shenzhen City, People's Republic of China; 2Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, People's Republic of China*These authors contributed equally to this workObjective: To compare the safety, efficacy, and impact on stent graft positioning between rapid artificial cardiac pacing (RACP, induced hypotension and sodium nitroprusside (SNP induced hypotension during thoracic endovascular aortic repair (TEVAR for Stanford B aortic dissection.Methods: One hundred and sixty-eight patients, who were diagnosed with Stanford B aortic dissection and who underwent selective TEVAR in Guangdong General Hospital and the People's Hospital of Baoan District, Shenzhen, People's Republic of China, were enrolled in this study. Patients were randomly divided into a RACP group (n=77 and a SNP group (n=91. During localization and deployment of the stent graft, hypotension was induced by RACP or intravenous SNP, according to randomization. Hemodynamics, landing precision (deviation from planned placement site, duration of procedure, renal function, neurocognitive function, and incidence of endoleaks and paraplegia/hemiplegia were compared. Except for methods of inducing hypotension, TEVAR was performed according to the same protocol in each group.Results: RACP was successfully performed in all patients assigned to the RACP group. Compared with the SNP group, blood pressure was significantly lower (43±5 versus 81±6 mmHg, P=0.003 and the restoration time of blood pressure and the operation duration were significantly shorter (7±2 versus 451±87 seconds, P<0.001; 87±15 versus 106±18 minutes, P<0.001, respectively in the RACP group. Stent graft localization/deployment was more precise in the RACP

  20. Haemodynamic imaging of thoracic stent-grafts by computational fluid dynamics (CFD): presentation of a patient-specific method combining magnetic resonance imaging and numerical simulations.

    Science.gov (United States)

    Midulla, Marco; Moreno, Ramiro; Baali, Adil; Chau, Ming; Negre-Salvayre, Anne; Nicoud, Franck; Pruvo, Jean-Pierre; Haulon, Stephan; Rousseau, Hervé

    2012-10-01

    In the last decade, there was been increasing interest in finding imaging techniques able to provide a functional vascular imaging of the thoracic aorta. The purpose of this paper is to present an imaging method combining magnetic resonance imaging (MRI) and computational fluid dynamics (CFD) to obtain a patient-specific haemodynamic analysis of patients treated by thoracic endovascular aortic repair (TEVAR). MRI was used to obtain boundary conditions. MR angiography (MRA) was followed by cardiac-gated cine sequences which covered the whole thoracic aorta. Phase contrast imaging provided the inlet and outlet profiles. A CFD mesh generator was used to model the arterial morphology, and wall movements were imposed according to the cine imaging. CFD runs were processed using the finite volume (FV) method assuming blood as a homogeneous Newtonian fluid. Twenty patients (14 men; mean age 62.2 years) with different aortic lesions were evaluated. Four-dimensional mapping of velocity and wall shear stress were obtained, depicting different patterns of flow (laminar, turbulent, stenosis-like) and local alterations of parietal stress in-stent and along the native aorta. A computational method using a combined approach with MRI appears feasible and seems promising to provide detailed functional analysis of thoracic aorta after stent-graft implantation. • Functional vascular imaging of the thoracic aorta offers new diagnostic opportunities • CFD can model vascular haemodynamics for clinical aortic problems • Combining CFD with MRI offers patient specific method of aortic analysis • Haemodynamic analysis of stent-grafts could improve clinical management and follow-up.

  1. Optimal Covering Material for Stent-Grafts Placed in the Portal Vein in a Canine Model

    International Nuclear Information System (INIS)

    Ishii, Seigo; Sato, Morio; Sonomura, Tetsuo; Yamada, Katsuyuki; Tanihata, Hirohiko; Ishikawa, Hime; Terada, Masaki; Sahara, Shinya; Kawai, Nobuyuki; Kimura, Masashi; Mori, Ichiro

    2005-01-01

    Purpose. We evaluated the suitability of Dacron, polytetrafluoroethylene (PTFE), and small intestinal submucosa (SIS) as a covering material for stent-grafts placed in the portal vein as compared with a bare stent. Methods. Using 24 beagle dogs, either bare stents or stent-grafts covered with Dacron, PTFE, or SIS were placed in the main trunk of the portal vein in 6 animals each. Portography was performed immediately after stent placement, and at 2, 4, and 12 weeks thereafter. Next, the extracted stents or stent-grafts were examined histopathologically. Neointimal thickness adjacent to the stent wire and at the midportion between the stent wires was compared among the groups. Then, the neointimal thickness at the sub- and supragraft sites was compared between each stent-graft group. Serial changes in the histologic features of the thickened neointima were also investigated. Results. No significant difference was noted in the mean stenotic ratio of the portal vein diameter between the bare stent and PTFE groups, whereas it was significantly higher in the Dacron and SIS groups compared with the bare stent group. In neither of the studies on neointimal thickness adjacent to the stent wire and at the midportion between the stent wires were any significant differences noted between the neointimal thickness of the bare stent group and the sum of the neointimal thickness of the PTFE group, whereas the sum of the neointimal thickness of the Dacron and SIS groups was significantly greater than that of the bare stent group at both sites. In the comparison of the supragraft neointimal thickness, the SIS group showed significantly greater thickness than the PTFE group, while the difference between the Dacron and PTFE groups was not significant. In the comparison of the subgraft neointimal thickness, the Dacron and SIS groups showed significantly greater thickness than the PTFE group. Conclusion. The present results indicate that of the three covering materials examined here

  2. Development of an abdominal aortic aneurysm model for stent-graft insertion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyung; Lee, Jong Heon; Shin, Dong Ik; Sung, Kyu Bo; Ko, Gi Young; Lim, Jin Oh [College of Medicine, Univ. of Ulsan, Seoul (Korea, Republic of); Kim, Si Hoon [S and G Biotech Research Institute, Seoul (Korea, Republic of)

    2002-03-01

    To determine the efficacy of an abdominal aortic aneurysm model for stent-graft placement. The model consists of two parts, the heart and the vascular system. A peristaltic pump and a solenoid valve were used to simulate a pulsatile flow from the heart. A ball-shaped piece of clay was placed inside a square box and liquid silicone was poured. After the silicone was formed, the clay was removed and a silicone tube was used to connect the heart model and the aneurysm model. The silicone tube was also used to simulate the iliac arteries and one end of the artery was clampled and the other one was extended to water bath. Water at 37 .deg. C was circulated through the model, and the pressure at the thoracic aorta, aneurysm and iliac artery was measured with the outlet valve opening at 25, 50, and 100% before and after stent-graft placement. The liquid pressure measurements were 253/252, 271/162 and 264/166 mmHg at the thoracic aorta, aneurysm and iliac artery, respectively, when the outlet was 100% open. They were 173/121, 145/99, 145/106 mmHg when the outlet was 50% open, and 35/28, 61/44, 24/22 mmHg when it was 25% open. After placement of the stent-graft, the pressure measurements were 170/128, and 167/128 mmHg, respectively. Since it was easy to produce, the model was useful for in-vitro stent-graft testing, and a wide range of pressure could be applied.

  3. Stent-Graft Placement with Early Debridement and Antibiotic Treatment for Femoral Pseudoaneurysms in Intravenous Drug Addicts

    International Nuclear Information System (INIS)

    Fu, Qining; Meng, Xiyun; Li, Fenghe; Wang, Xuehu; Cheng, Jun; Huang, Wen; Ren, Wei; Zhao, Yu

    2015-01-01

    PurposeExplore the application of endovascular covered stent-graft (SG) placement in femoral pseudoaneurysms in intravenous drug addicts.Materials and MethodsWe evaluated a consecutive series of pseudoaneurysm in intravenous drug addicts treated with SGs from August 2010 to December 2013.Results15 patients with 16 arterial pseudoaneurysms were enrolled in this study. All were males with a mean age of 36.9 years. Hemorrhage was the most common reason (93.8 %) for seeking medical care, and 3 of these patients were in hemorrhagic shock at admission. All patients received broad-spectrum antibiotics, and debridement and drainage were implemented after SG placement. 7 of the 13 cases which had microbiologic results showed mixed infections, while gram-negative bacteria were the major pathogens. Except for 2 patients, who were lost to follow-up, two new pseudoaneurysms formed due to delayed debridement, and one stent thrombosis occurred, none of the remaining cases had SG infection or developed claudication.ConclusionsSG placement controls massive hemorrhage rapidly, gives enough time for subsequent treatment for pseudoaneurysms due to intravenous drug abuse, and reduces the incidence of postoperative claudication. With appropriate broad-spectrum antibiotics and early debridement, the incidence of SG infection is relatively low. It is an effective alternative especially as temporary bridge measure for critical patients. However, the high cost, uncertain long-term prospects, high demand for medical adherence, and the risk of using the conduits for re-puncture call for a cautious selection of patients. More evidence is required for the application of this treatment

  4. Stent-Graft Placement with Early Debridement and Antibiotic Treatment for Femoral Pseudoaneurysms in Intravenous Drug Addicts

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Qining, E-mail: cqmufqn@163.com; Meng, Xiyun, E-mail: 383274177@qq.com; Li, Fenghe, E-mail: lfh-cqmu@gmail.com; Wang, Xuehu, E-mail: 184037696@qq.co; Cheng, Jun, E-mail: cqdcj@163.com; Huang, Wen, E-mail: dhuangwen@hotmail.com; Ren, Wei, E-mail: renwei9771@yahoo.com.cn; Zhao, Yu, E-mail: zhaoyu-cqmu@126.com [The First Affiliated Hospital of Chongqing Medical University, Department of Vascular Surgery (China)

    2015-06-15

    PurposeExplore the application of endovascular covered stent-graft (SG) placement in femoral pseudoaneurysms in intravenous drug addicts.Materials and MethodsWe evaluated a consecutive series of pseudoaneurysm in intravenous drug addicts treated with SGs from August 2010 to December 2013.Results15 patients with 16 arterial pseudoaneurysms were enrolled in this study. All were males with a mean age of 36.9 years. Hemorrhage was the most common reason (93.8 %) for seeking medical care, and 3 of these patients were in hemorrhagic shock at admission. All patients received broad-spectrum antibiotics, and debridement and drainage were implemented after SG placement. 7 of the 13 cases which had microbiologic results showed mixed infections, while gram-negative bacteria were the major pathogens. Except for 2 patients, who were lost to follow-up, two new pseudoaneurysms formed due to delayed debridement, and one stent thrombosis occurred, none of the remaining cases had SG infection or developed claudication.ConclusionsSG placement controls massive hemorrhage rapidly, gives enough time for subsequent treatment for pseudoaneurysms due to intravenous drug abuse, and reduces the incidence of postoperative claudication. With appropriate broad-spectrum antibiotics and early debridement, the incidence of SG infection is relatively low. It is an effective alternative especially as temporary bridge measure for critical patients. However, the high cost, uncertain long-term prospects, high demand for medical adherence, and the risk of using the conduits for re-puncture call for a cautious selection of patients. More evidence is required for the application of this treatment.

  5. Endovascular Treatment of a Bleeding Secondary Aorto-Enteric Fistula. A Case Report with 1-Year Follow-up

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Vasdekis, Spyros; Kostopanagiotou, Georgia; Danias, Nikolaos; Alexopoulou, Efthymia; Petropoulou, Konstantina; Gouliamos, Athanasios; Perros, Georgios

    2007-01-01

    We report a patient with life-threatening gastrointestinal bleeding caused by a secondary aorto-enteric fistula. Because the patient had several comorbid conditions, we successfully stopped the bleeding by endovascular placement of a bifurcated aortic stent-graft. The patient developed periaortic infection 4 months later, but he was managed with antibiotics. The patient is well 1 year after the procedure

  6. Mechanical properties of various z-stent designs: an endovascular stent-grafting perspective.

    Science.gov (United States)

    Bashar, Abul Hasan Muhammad; Kazui, Teruhisa; Washiyama, Naoki; Terada, Hitoshi; Yamashita, Katsushi; Haque, Mohammad E

    2003-08-01

    To comparatively assess the mechani-cal behavior of various clinically relevant Z-stent designs. A total of 16 Z-stents of original, biliary, spiral, and double-skirted designs (n=4 for each) were constructed using similar specifications for all. Stents were then evaluated for stiffness, snap opening force (SOF), flexibility, and displacement force using a novel tensiometer. Differences among the stents were determined using statistical methods. Stents explanted from dog aorta after a mean follow-up of 13 months were examined under a scanning electron microscope for surface defects. Forces required for about 50% reduction in diameter were 1.88 +/- 0.16 N, 3.81 +/- 0.21 N, 2.76 +/- 0.22 N, and 3.35 +/- 0.19 N for original, biliary, spiral, and skirted designs, respectively. Differences among the four designs were statistically significant at almost all points of measurement (P designs showed higher SOF values in the early measurements. Stents explanted from dog aorta after a mean duration of 13 months showed no obvious corrosion or breakage in the wire struts. Significant differences exist among the various Z-stent designs in terms of their mechanical properties. Understanding them should help to select the appropriate stent for a given lesion. 316L stainless steel shows a favorable long-term tissue interaction.

  7. Extrahepatic Pseudoaneurysms and Ruptures of the Hepatic Artery in Liver Transplant Recipients: Endovascular Management and a New Iatrogenic Etiology

    International Nuclear Information System (INIS)

    Saad, Wael E. A.; Dasgupta, Niloy; Lippert, Allison J.; Turba, Ulku C.; Davies, Mark G.; Kumer, Sean; Gardenier, Jason C.; Sabri, Saher S.; Park, Auh-Whan; Waldman, David L.; Schmitt, Timothy; Matsumoto, Alan H.; Angle, John F.

    2013-01-01

    To characterize extrahepatic pseudoaneurysm regarding incidence and etiology and determine the effectiveness of endovascular management. A retrospective audit of 1,857 liver transplants in two institutions was performed (1996–2009). Recipients’ demographics, clinical presentation, transplant type, biliary anastomosis, and presence of biliary endoprostheses were noted. Pseudoaneurysms were classified into iatrogenic (associated with biliary endoprosthesis or angioplasty) or spontaneous extrahepatic pseudoaneurysms. Spontaneous and iatrogenic pseudoaneurysms were compared for time from transplant, presenting symptoms, location in the arterial anatomy, and 3-month graft survival. Arterial patency and 6-month graft survival were calculated. Twenty pseudoaneurysms were found (1.1 %, 20/1,857): 9 (0.5 % of transplants, 9/1,857) were spontaneous and 11 (0.6 % of transplants, 11/1,857) were “iatrogenic” (due to minimally invasive procedures: 4 angioplasty and 7 biliary endoprostheses). Sixty percent (12/20) underwent endovascular management (4 coil embolization and 8 stent-grafts). Technical success was 83 % (10/12) with a mean arterial patency of 70 % (follow-up mean, 4.9; range, 0–18 months). The 1-, 3-, and 6-month graft survival was 70, 40, and 35 %, respectively. Due to minimally invasive procedures, posttransplant extrahepatic pseudoaneurysms are no longer an exclusive complication of the transplant surgery itself. Endovascular management is effective to stabilize patients but has not improved historic postsurgical graft survival.

  8. Extrahepatic Pseudoaneurysms and Ruptures of the Hepatic Artery in Liver Transplant Recipients: Endovascular Management and a New Iatrogenic Etiology

    Energy Technology Data Exchange (ETDEWEB)

    Saad, Wael E. A., E-mail: wspikes@yahoo.com; Dasgupta, Niloy; Lippert, Allison J.; Turba, Ulku C.; Davies, Mark G. [University of Virginia Health System, Division of Vascular Interventional Radiology, Department of Radiology (United States); Kumer, Sean [University of Virginia Health System, Division of Solid Organ Transplantation, Department of Surgery (United States); Gardenier, Jason C.; Sabri, Saher S.; Park, Auh-Whan [University of Virginia Health System, Division of Vascular Interventional Radiology, Department of Radiology (United States); Waldman, David L. [University of Rochester Medical Center, Department of Imaging Sciences (United States); Schmitt, Timothy [University of Virginia Health System, Division of Solid Organ Transplantation, Department of Surgery (United States); Matsumoto, Alan H.; Angle, John F. [University of Virginia Health System, Division of Vascular Interventional Radiology, Department of Radiology (United States)

    2013-02-15

    To characterize extrahepatic pseudoaneurysm regarding incidence and etiology and determine the effectiveness of endovascular management. A retrospective audit of 1,857 liver transplants in two institutions was performed (1996-2009). Recipients' demographics, clinical presentation, transplant type, biliary anastomosis, and presence of biliary endoprostheses were noted. Pseudoaneurysms were classified into iatrogenic (associated with biliary endoprosthesis or angioplasty) or spontaneous extrahepatic pseudoaneurysms. Spontaneous and iatrogenic pseudoaneurysms were compared for time from transplant, presenting symptoms, location in the arterial anatomy, and 3-month graft survival. Arterial patency and 6-month graft survival were calculated. Twenty pseudoaneurysms were found (1.1 %, 20/1,857): 9 (0.5 % of transplants, 9/1,857) were spontaneous and 11 (0.6 % of transplants, 11/1,857) were 'iatrogenic' (due to minimally invasive procedures: 4 angioplasty and 7 biliary endoprostheses). Sixty percent (12/20) underwent endovascular management (4 coil embolization and 8 stent-grafts). Technical success was 83 % (10/12) with a mean arterial patency of 70 % (follow-up mean, 4.9; range, 0-18 months). The 1-, 3-, and 6-month graft survival was 70, 40, and 35 %, respectively. Due to minimally invasive procedures, posttransplant extrahepatic pseudoaneurysms are no longer an exclusive complication of the transplant surgery itself. Endovascular management is effective to stabilize patients but has not improved historic postsurgical graft survival.

  9. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  10. Dissection of descending aorta treated by stent-graft implantation in a patient with Marfan syndrome

    Directory of Open Access Journals (Sweden)

    Marat A. Aripov

    2017-04-01

    Full Text Available This report describes a 32 years old patient with Marfan syndrome and hypertension. David`s procedure was performed to the patient three months before due to dissection of the ascending thoracic aorta. Computer tomography scan showed DeBakey type III dissection of aorta beginning from left subclavian artery with transition to the ostium of the celiac trunk and proximal part of the left common iliac artery. Stent-grafts in the descending thoracic aorta with overlapping of left subclavian artery were implanted to the patient with Marfan syndrome. Patient was discharged and no complications recorded at 6th month follow-up.

  11. Percutaneous Endoluminal Stent-Graft Repair of an Old Traumatic Femoral Arteriovenous Fistula

    International Nuclear Information System (INIS)

    Uflacker, Renan; Elliott, Bruce M.

    1996-01-01

    A stent-graft was custom made to close a high-flow traumatic arteriovenous fistula of the left superficial femoral artery, present for 30 years, in a 60-year-old man with congestive heart failure and ischemic ulceration in the left foot. A balloon expandable Palmaz stent (P394; 2.5 mm x 3.9 cm) was covered with a polytetrafluoroethylene (PTFE) graft and was inserted percutaneously through an 11 Fr vascular sheath. Follow-up Doppler ultrasound at 6 months demonstrated occlusion of the arteriovenous fistula, patency of the artery, and luminal integrity of the artery and vein

  12. Use of a Stent Graft for Patent Ductus Arteriosus in an Octogenarian Eliminates Ductus Flow.

    Science.gov (United States)

    Tatsuishi, Wataru; Kataoka, Go; Asano, Ryota; Sato, Atsuhiko; Nakano, Kiyoharu

    2016-06-20

    Closure of a patent ductus arteriosus (PDA) in the elderly is a high-risk procedure because of tissue fragility and many possible complications. The patient in our case was an 81-year-old woman with a window-type PDA caused by cardiac failure. Based on the anatomy of the PDA and aorta and to minimize invasion, we used a stent graft to close the PDA. This approach was successful; hemodynamics improved and ductus flow was eliminated during the follow-up period without intervention from the pulmonary artery side.

  13. Endovascular Repair of Acute Symptomatic Pararenal Aortic Aneurysm With Three Chimney and One Periscope Graft for Complete Visceral Artery Revascularization

    International Nuclear Information System (INIS)

    Brechtel, Klaus; Ketelsen, Dominik; Endisch, Andrea; Heller, Stephan; Heuschmid, Martin; Stock, Ulrich A.; Kalender, Guenay

    2012-01-01

    PurposeTo describe a modified endovascular technique for complete revascularization of visceral and renal arteries in symptomatic pararenal aortic aneurysm (PRAA).TechniqueArterial access was surgically established in both common femoral arteries (CFAs) and the left subclavian artery (LSA). Revascularization of the left renal artery, the celiac trunk, and the superior mesenteric artery was performed through one single sheath via the LSA. Suitable covered stents were put in the aortic branches but not deployed. The right renal artery was accessed over the left CFA. Due to the longitudinal extension of the presented aneurysm two stent-grafts were introduced via the right CFA. After deploying the aortic stent-grafts, all covered stents in the side branches were deployed consecutively with a minimum overlap of 5 mm over the cranial and caudal stent-graft edges. Simultaneous ballooning was performed to fully expand all stent-grafts and warranty patency. Conclusion: This is the first report in the literature of chimney grafting in PRAA for complete revascularization of visceral and renal branches by using more than two covered stents introduced from one side through one single sheath. However this technique is modified, it should be used only in bailout situations when branched stent-grafts are not available and/or surgery is not suitable.

  14. Coronary artery aneurysm after stent implantation: acute and long-term results after percutaneous treatment with a stent graft.

    Science.gov (United States)

    Rubartelli, Paolo; Terzi, Giacomo; Borgo, Lorenzo; Giachero, Corinna

    2002-03-01

    A patient with unstable angina was treated with elective Palmaz-Schatz stent implantation on a focal stenosis of the left circumflex artery. One year later, a large (13 mm in diameter) coronary artery aneurysm was diagnosed at angiography in the stented site. Intravascular ultrasound examination confirmed the presence of a true aneurysm located at the proximal end of the stent. The aneurysm was successfully treated with a Jostent Graft (Jomed Implantate) consisting of two slotted tube stainless steel stents supporting a polytetrafluoroethylene tube. The stent graft was implanted under intravascular ultrasound guidance. The 18-month angiographic follow-up showed good patency of the stent graft and complete exclusion of the aneurysm.

  15. Mid-Term Outcomes of Endovascular Treatment for TASC-II D Femoropopliteal Occlusive Disease with Critical Limb Ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Torres-Blanco, Álvaro, E-mail: atorres658@yahoo.es; Edo-Fleta, Gemma; Gómez-Palonés, Francisco; Molina-Nácher, Vicente; Ortiz-Monzón, Eduardo [Hospital Universitario Dr. Peset, Department of Angiology, Endovascular and Vascular Surgery (Spain)

    2016-03-15

    PurposeThe purpose of the study was to assess the safety and midterm effectiveness of endovascular treatment in Trans-Atlantic Inter-Society Consensus II (TASC-II) D femoropopliteal occlusions in patients with critical limb ischemia (CLI).MethodsPatients with CLI who underwent endovascular treatment for TASC-D de novo femoropopliteal occlusive disease between September 2008 and December 2013 were selected. Data included anatomic features, pre- and postprocedure ankle-brachial index, duplex ultrasound, and periprocedural complications. Sustained clinical improvement, limb salvage rate, freedom from target lesion revascularization (TLR), and freedom from target extremity revascularization (TER) were assessed by Kaplan–Meier estimation and predictors of restenosis/occlusion with Cox analysis.ResultsThirty-two patients underwent treatment of 35 TASC-D occlusions. Mean age was 76 ± 9. Mean lesion length was 23 ± 5 cm. Twenty-eight limbs (80 %) presented tissue loss. Seventeen limbs underwent treatment by stent, 13 by stent-graft, and 5 by angioplasty. Mean follow-up was 29 ± 20 months. Seven patients required major amputation and six patients died during follow-up. Eighteen endovascular and three surgical TLR procedures were performed due to restenosis or occlusion. Estimated freedom from TLR and TER rates at 2 years were 41 and 76 %, whereas estimated primary and secondary patency rates were 41 and 79 %, respectively.ConclusionsEndovascular treatment for TASC II D lesions is safe and offers satisfying outcomes. This patient subset would benefit from a minimally invasive approach. Follow-up is advisable due to a high rate of restenosis. Further follow-up is necessary to know the long-term efficacy of these procedures.

  16. Endovascular management of acute bleeding arterioenteric fistulas

    DEFF Research Database (Denmark)

    Leonhardt, H.; Mellander, S.; Snygg, J.

    2008-01-01

    follow-up time was 3 months (range, 1-6 months). All massive bleeding was controlled by occlusive balloon catheters. Four fistulas were successfully sealed with stent-grafts, resulting in a technical success rate of 80%. One patient was circulatory stabilized by endovascular management but needed....... All had massive persistent bleeding with hypotension despite volume substitution and transfusion by the time of endovascular management. Outcome after treatment of these patients was investigated for major procedure-related complications, recurrence, reintervention, morbidity, and mortality. Mean...... arterioenteric fistulas in the emergent episode. However, in this group of patients with severe comorbidities, the risk of rebleeding is high and further intervention must be considered. Patients with cancer may only need treatment for the acute bleeding episode, and an endovascular approach has the advantage...

  17. Massive Bleeding from Guidewire Perforation of an External Iliac Artery: Treatment with Hand-made Stent-Graft Placement

    Energy Technology Data Exchange (ETDEWEB)

    Mehta, Vimal, E-mail: drvimalmehta@yahoo.co.in; Pandit, Bhagya Narayan; Mehra, Pratishtha; Nigam, Arima; Vyas, Aniruddha; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay [G.B. Pant Institute of Postgraduate Medical Education and Research (India)

    2016-01-15

    We report life-threatening bleeding from an external iliac artery perforation following guidewire manipulation in a patient with atherosclerotic iliac artery disease. This complication was successfully managed by indigenous hand-made stent-graft made from two peripheral stents in the catheterization laboratory.

  18. Massive Bleeding from Guidewire Perforation of an External Iliac Artery: Treatment with Hand-made Stent-Graft Placement

    International Nuclear Information System (INIS)

    Mehta, Vimal; Pandit, Bhagya Narayan; Mehra, Pratishtha; Nigam, Arima; Vyas, Aniruddha; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay

    2016-01-01

    We report life-threatening bleeding from an external iliac artery perforation following guidewire manipulation in a patient with atherosclerotic iliac artery disease. This complication was successfully managed by indigenous hand-made stent-graft made from two peripheral stents in the catheterization laboratory

  19. An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents

    Directory of Open Access Journals (Sweden)

    Jing Lin

    2016-02-01

    Full Text Available Whereas buckling can cause type III endoleaks, long-term twisting of a stent-graft was investigated here as a mechanism leading to type V endoleak or endotension. Two experimental device designs supported with Z-stents having strut angles of 35° or 45° were compared to a ringed control under accelerated twisting. Damage to each device was assessed and compared after different durations of twisting, with focus on damage that may allow leakage. Stent-grafts with 35° Z-stents had the most severe distortion and damage to the graft fabric. The 45° Z-stents caused less fabric damage. However, consistent stretching was still seen around the holes for sutures, which attach the stents to the graft fabric. Larger holes may become channels for fluid percolation through the wall. The ringed stent-graft had the least damage observed. Stent apexes with sharp angles appear to be responsible for major damage to the fabrics. Device manufacturers should consider stent apex angle when designing stent-grafts, and ensure their devices are resistant to twisting.

  20. Self-Expandable Stenting over a Stent Graft for the Exclusion of a Carotid Stump: Troubleshooting for Device Incompatibility

    International Nuclear Information System (INIS)

    Youn, Sung Won; Kim, Ho Kyun; Do, Jin Kook; Kim, Young Whan

    2011-01-01

    Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.

  1. An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents.

    Science.gov (United States)

    Lin, Jing; Guidoin, Robert; Du, Jia; Wang, Lu; Douglas, Graeham; Zhu, Danjie; Nutley, Mark; Perron, Lygia; Zhang, Ze; Douville, Yvan

    2016-02-16

    Whereas buckling can cause type III endoleaks, long-term twisting of a stent-graft was investigated here as a mechanism leading to type V endoleak or endotension. Two experimental device designs supported with Z-stents having strut angles of 35° or 45° were compared to a ringed control under accelerated twisting. Damage to each device was assessed and compared after different durations of twisting, with focus on damage that may allow leakage. Stent-grafts with 35° Z-stents had the most severe distortion and damage to the graft fabric. The 45° Z-stents caused less fabric damage. However, consistent stretching was still seen around the holes for sutures, which attach the stents to the graft fabric. Larger holes may become channels for fluid percolation through the wall. The ringed stent-graft had the least damage observed. Stent apexes with sharp angles appear to be responsible for major damage to the fabrics. Device manufacturers should consider stent apex angle when designing stent-grafts, and ensure their devices are resistant to twisting.

  2. Self-Expandable Stenting over a Stent Graft for the Exclusion of a Carotid Stump: Troubleshooting for Device Incompatibility

    Energy Technology Data Exchange (ETDEWEB)

    Youn, Sung Won; Kim, Ho Kyun [Dept. of Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Do, Jin Kook [Dept. of Neurology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Whan [Dept. of Radiology, University College of Medicine, Daegu (Korea, Republic of)

    2011-12-15

    Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.

  3. Anatomic study of juxta renal aneurysms: impact on fenestrated stent-grafts.

    Science.gov (United States)

    Azzaoui, Richard; Sobocinski, Jonathan; Maurel, Blandine; D'Elia, Piervito; Perrot, Céline; Bianchini, Aurélia; Guillou, Matthieu; Haulon, Stéphan

    2011-04-01

    Fenestrated stent-grafts allow for treatment of patients with juxtarenal aneurysms (JRA) when they present with contraindications for conventional treatment. The fenestrated module is a custom-made module, specially designed to fit a specific patient, using computed tomographic scan measurements, which entails manufacturing delay and high cost. The aim of our study was to evaluate the possibility to reproduce the interrenal aorta anatomy to design a standard fenestrated module that would fit the maximum number of patients with JRA. On a three-dimensional working station, we analyzed 289 preoperative computed tomographic scan results of patients with JRA and who were treated with fenestrated stent-grafts comprising two fenestrations for the renal arteries and a scallop for the superior mesenteric artery (SMA). On curvilinear reconstructions, we successively measured the interrenal aorta diameter, its orientation, as well as the height of each renal ostium, taking the ostium center of the SMA as a reference mark. Later, a statistical analysis of these measures distribution was performed so as to design a fenestrated module that would fit the maximum number of patients. The center of the left renal artery presented with a median orientation of 82.5° (range, 37.5-150) and a median distance of 9 mm (range, 0-30), in relation to the SMA ostium. The ostium center of the right renal artery presented with a median orientation of 285° (range, 240-337.5) and a median distance of 8 mm (range, 3-30), in relation to the SMA ostium. By positioning the current renal fenestrations (6-mm wide), on the basis of the calculated median positions, in our series, only 20% of the patients could be treated with a standard fenestrated module. Should the diameter of these fenestrations be increased by 10 mm, it would then be possible to treat 50% of our patients. The anatomy of the interrenal aorta and its branches is quite reproducible to design standard fenestrated stent-grafts that could

  4. Endovascular aneurysm exclusion along a femorodistal venous bypass in active Behçet's disease.

    Science.gov (United States)

    Gretener, Silvia B; Do, Dai-Do; Baumgartner, Iris; Dinkel, Hans-Peter; Schmidli, Jürg; Birrer, Manuela

    2002-10-01

    To report the endovascular repair of dual aneurysms along a femorodistal venous bypass graft in a patient with Behçet's disease. A 55-year-old man of middle European ancestry with Behçet's disease had dual aneurysms evolve along the proximal segment of a femorodistal venous bypass that had been implanted 2.5 years earlier for recurrent false aneurysm formation. Owing to the lack of suitable venous conduits and the active nature of the disease, the aneurysms were successfully excluded with overlapping Hemobahn and Jostent endografts; the immunosuppressive therapy was intensified. Rupture of the aneurysms was successfully prevented, but the stent-grafts thrombosed 6 weeks later owing to exacerbation of the underlying disease. Endovascular exclusion of aneurysm in venous bypass grafts in Behçet's disease is feasible. Although the stent-grafts thrombosed, they did prevent rupture of the aneurysms.

  5. [Classification and treatment of endoleaks after endovascular treatment of abdominal aortic aneurysms].

    Science.gov (United States)

    Pitton, M B; Schmiedt, W; Neufang, A; Düber, C; Thelen, M

    2005-01-01

    This article describes the classification of endoleaks after endovascular treatment of abdominal aortic aneurysms, thereby summarizing the most important problems of this endovascular technique. The correct classification of endoleaks is a prerequisite for interdisciplinary discussion. It is indispensable for professional reporting of the pathological findings and for the decision making as to the adequate treatment of endoleaks. Irrespective of the types of stent graft and property of the material, five endoleak types are defined in the literature: leakage at the anchor sites (type I); leakage due to collateral arteries (type II); defective stent grafts (type III); leakage due to porosity of the graft material (type IV); and endotension (type V). The causes of endoleaks are discussed and treatment options are reviewed for the diverse pathologic findings.

  6. Classification and treatment of endoleaks after endovascular treatment of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Pitton, M.B.; Thelen, M.; Schmiedt, W.; Neufang, A.; Dueber, C.

    2005-01-01

    This article describes the classification of endoleaks after endovascular treatment of abdominal aortic aneurysms, thereby summarizing the most important problems of this endovascular technique. The correct classification of endoleaks is a prerequisite for interdisciplinary discussion. It is indispensable for professional reporting of the pathological findings and for the decision making as to the adequate treatment of endoleaks. Irrespective of the types of stent graft and property of the material, five endoleak types are defined in the literature: leakage at the anchor sites (type I); leakage due to collateral arteries (type II); defective stent grafts (type III); leakage due to porosity of the graft material (type IV); and endotension (type V). The causes of endoleaks are discussed and treatment options are reviewed for the diverse pathologic findings. (orig.)

  7. Bronchobiliary Fistula Treated by Self-expanding ePTFE-Covered Nitinol Stent-Graft

    International Nuclear Information System (INIS)

    Gandini, Roberto; Konda, Daniel; Tisone, Giuseppe; Pipitone, Vincenzo; Anselmo, Alessandro; Simonetti, Giovanni

    2005-01-01

    A 71-year-old man, who had undergone right hepatectomy extended to the caudate lobe with terminolateral Roux-en-Y left hepatojejunostomy for a Klatskin tumor, developed bilioptysis 3 weeks postoperatively due to bronchobiliary fistula. Percutaneous transhepatic cholangiography revealed a non-dilated biliary system with contrast medium extravasation to the right subphrenic space through a resected anomalous right posterior segmental duct. After initial unsuccessful internal-external biliary drainage, the fistula was sealed with a VIATORR covered self-expanding nitinol stent-graft placed with its distal uncovered region in the hepatojejunal anastomosis and the proximal ePTFE-lined region in the left hepatic duct. A 10-month follow-up revealed no recurrence of bilioptysis and confirmed the complete exclusion of the bronchobiliary fistula

  8. Emergency Endovascular “Bridge” Treatment for Iliac-Enteric Fistula

    International Nuclear Information System (INIS)

    Franchin, Marco; Tozzi, Matteo; Piffaretti, Gabriele; Carrafiello, Gianpaolo; Castelli, Patrizio

    2011-01-01

    Aortic aneurysm has been reported to be the dominant cause of primary iliac-enteric fistula (IEF) in >70% of cases [1]; other less common causes of primary IEF include peptic ulcer, primary aortitis, pancreatic pseudocyst, or neoplastic erosion into an adjacent artery [2, 3]. We describe an unusual case of IEF managed with a staged approach using an endovascular stent-graft as a “bridge” in the emergency setting to optimize the next elective definitive excision of the lesion.

  9. Successful endovascular treatment of a hemodialysis graft pseudoaneurysm by covered stent and direct percutaneous thrombin injection.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2011-07-25

    Vascular access for hemodialysis remains a challenge for nephrologists, vascular surgeons, and interventional radiologists alike. Arteriovenous fistula and synthetic grafts remain the access of choice for long-term hemodialysis; however, they are subject to complications from infection and repeated needle cannulation. Pseudoaneurysms are an increasingly recognized adverse event. At present, there are many minimally invasive methods to repair these wall defects. We present a graft pseudoaneurysm, which required a combination of endovascular stent graft placement and percutaneous thrombin injection for successful occlusion.

  10. Concepts to optimize stent-grafting of abdominal aortic aneurysms based on results of experimental studies

    International Nuclear Information System (INIS)

    Chavan, A.; Kirchhoff, T.; Baus, S.; Galanski, M.; Pichlmaier, M.

    2001-01-01

    Purpose. In the endoluminal therapy of abdominal aortic aneurysms, a short proximal aneurysm neck, endoleaks and the large size and stiffness of the introducer systems are responsible for many of the complications and sub-optimal outcomes. The purpose of the present review article is to to suggest strategies to minimize these complications based on the results of experimental studies in animals. Material and methods. After implanting various types of stents across the renal artery origins, the functional and morphological changes in the kidneys and renal vessels were studied by various authors. In order to prevent progressive widening of the proximal aneurysmal neck and graft dislocation, Sonesson et al. performed a laparoscopic banding around the proximal neck in pigs. To study the effects of endoleaks, Marty, Schurink and Pitton carried out pressure measurements in experimental aneurysms with and without endoleaks. Sakaguchi and Pavcnik developed the 'Twin-tube endografts' (TTEG) and the 'Bifurcated drum occluder endografts' (BDOEG) and tested them in dogs. Results. Up to 3 months after suprarenal stent placement, Chavan et al. detected no significant fall in the mean inulin clearance in sheep (140±46 ml/min before, 137±58 ml/min after). Nasim et al. and Malina et al. reported similar observations with respect to renal function. Suprarenal fixation may result in isolated thrombotic occlusions of the renal arteries and microinfarcts in the kidneys. Mean aortic diameters at the level of banding were significantly smaller in the animals with aortic banding as opposed to those in the control group without banding (8 mm vs 11 mm, p=0.004). The banding caused a secure proximal fixation of the stent-graft. Persistent endoleaks resulted in significantly higher intraaneurysmal pressures. Although the TTEG and the BDOEG stent-grafts required smaller sheaths, occlusions were observed in 8% (TTEG) and 60% (BDOEG) of the graft limbs. (orig.) [de

  11. Emergency Endovascular Treatment of Abdominal Aortic Aneurysms: Feasibility and Results

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Fontana, Federico; Caronno, Roberto; Castelli, Patrizio; Cuffari, Salvatore; Fugazzola, Carlo

    2006-01-01

    Purpose. To assess the feasibility and effectiveness of emergency endovascular treatment of abdominal aortic aneurysms (AAAs). Methods. During 36 months we treated, on an emergency basis, 30 AAAs with endovascular exclusion. In 21 hemodynamically stable patients preoperative CT angiography (CTA) was performed to confirm the diagnosis and to plan the treatment; 9 patients with hemorrhagic shock were evaluated with angiography performed in the operating room. Twenty-two Excluder (Gore) and 8 Zenith (Cook) stent-grafts (25 bifurcated and 5 aorto-uni-iliac) were used. The follow-up was performed by CTA at 1, 3, 6, and 12 months. Results. Technical success was achieved in 100% of cases with a 10% mortality rate. The total complication rate was 23% (5 increases in serum creatinine level and 2 wound infections). During the follow-up, performed in 27 patients (1-36 months, mean 15.2 months), 4 secondary endoleaks (15%) (3 type II, 2 spontaneously thrombosed and 1 under observation, and 1 type III treated by iliac extender insertion) and 1 iliac leg occlusion (treated with femoro-femoral bypass) occurred. We observed a shrinkage of the aneurysmal sac in 8 of 27 cases and stability in 19 of 27 cases; we did not observe any endotension. Conclusions. Endovascular repair is a good option for emergency treatment of AAAs. The team's experience allows correct planning of the procedure in emergency situations also, with technical results comparable with elective repair. In our experience the bifurcated stent-graft is the device of choice in patients with suitable anatomy because the procedure is less time-consuming than aorto-uni-iliac stent-grafting with surgical crossover, allowing faster aneurysm exclusion. However, further studies are required to demonstrate the long-term efficacy of endovascular repair compared with surgical treatment

  12. Endovascular Aortic Aneurysm Repair for Abdominal Aortic Aneurysm: Single Center Experience in 122 Patients

    International Nuclear Information System (INIS)

    Lee, Yun Young; Song, Jang Hyeon; Kim, Yong Tae; Yim, Nam Yeol; Kim, Jae Kyu; Lee, Ho Kyun; Choi, Soo Jin Na; Chung, Sang Young; Kim, Soo Hyun; Chang, Nam Kyu

    2013-01-01

    To analyze a single center experience of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms. Results of 122 patients who underwent EVAR were analyzed, retrospectively. Sex, age, aneurysmal morphology, hostile neck anatomy, preprocedural and postprocedural sac-diameter, technical and clinical success, postprocedural complication and need of additional procedure were analyzed. A total of 111 male and 11 female patients were included. Morphology of the aneurysms was as follows: fusiform (n = 108), saccular (n = 3) and ruptured type (n = 11). Sixty-four patients had hostile neck anatomy. The preprocedural mean sac-diameter was 52.4 mm. Postprocedural sac-diameter was decreased or stable in 110 patients (90.2%) and increased in 8 patients (6.6%). Technical success rate was 100% and clinical success rate was 86.1%. Fifty-one patients showed endoleak (41.8%) and 15 patients (12.3%) underwent secondary intervention due to type I endoleak (n = 4), type II endoleak (n = 4) and stent-graft thrombosis (n = 7). EVAR is a safe and effective therapy for abdominal aortic aneurysm, and it has high technical success and clinical success rate, and low complication rate.

  13. Heparin-bonded, expanded polytetrafluoroethylene-lined stent graft in the treatment of femoropopliteal artery disease: 1-year results of the VIPER (Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease) trial.

    Science.gov (United States)

    Saxon, Richard R; Chervu, Arun; Jones, Paul A; Bajwa, Tanvir K; Gable, Dennis R; Soukas, Peter A; Begg, Richard J; Adams, John G; Ansel, Gary M; Schneider, Darren B; Eichler, Charles M; Rush, Michael J

    2013-02-01

    To evaluate the performance of a heparin-bonded, expanded polytetrafluoroethylene (ePTFE)-lined nitinol endoprosthesis in the treatment of long-segment occlusive disease of the femoropopliteal artery (FPA) and to identify factors associated with loss of patency. In a single-arm, prospective, 11-center study (VIPER [Gore Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease] trial), 119 limbs (113 patients; 69 men; mean age, 67 y), including 88 with Rutherford category 3-5 disease and 72 with Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II) C or D lesions of the FPA, underwent stent graft implantation. The mean lesion length was 19 cm; 56% of lesions were occlusions. Follow-up evaluations included color duplex ultrasonography in all patients, with patency defined as a peak systolic velocity ratio20% was 70% (P = .047). Primary patency was not significantly affected by device diameter (5 vs 6 vs 7 mm) or lesion length (≤20 cm vs>20 cm). The 30-day major adverse event rate was 0.8%. The heparin-bonded, ePTFE/nitinol stent graft provided clinical improvement and a primary patency rate of 73% at 1 year in the treatment of long-segment FPA disease. Careful sizing of the device relative to vessel landing zones is essential for achieving optimal outcomes. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  14. Long-Term Follow-Up After Endovascular Treatment of Acute Aortic Emergencies

    International Nuclear Information System (INIS)

    Pitton, M. B.; Herber, S.; Schmiedt, W.; Neufang, A.; Dorweiler, B.; Dueber, C.

    2008-01-01

    Purpose. To investigate the long-term outcome and efficacy of emergency treatment of acute aortic diseases with endovascular stent-grafts. Methods. From September 1995 to April 2007, 37 patients (21 men, 16 women; age 53.9 ± 19.2 years, range 18-85 years) with acute complications of diseases of the descending thoracic aorta were treated by endovascular stent-grafts: traumatic aortic ruptures (n = 9), aortobronchial fistulas due to penetrating ulcer or hematothorax (n = 6), acute type B dissections with aortic wall hematoma, penetration, or ischemia (n = 13), and symptomatic aneurysm of the thoracic aorta (n = 9) with pain, penetration, or rupture. Diagnosis was confirmed by contrast-enhanced CT. Multiplanar reformations were used for measurement of the landing zones of the stent-grafts. Stent-grafts were inserted via femoral or iliac cut-down. Two procedures required aortofemoral bypass grafting prior to stent-grafting due to extensive arteriosclerotic stenosis of the iliac arteries. In this case the bypass graft was used for introduction of the stent-graft. Results. A total of 46 stent-grafts were implanted: Vanguard/Stentor (n = 4), Talent (n = 31), and Valiant (n = 11). Stent-graft extension was necessary in 7 cases. In 3 cases primary graft extension was done during the initial procedure (in 1 case due to distal migration of the graft during stent release, in 2 cases due to the total length of the aortic aneurysm). In 4 cases secondary graft extensions were performed-for new aortic ulcers at the proximal stent struts (after 5 days) and distal to the graft (after 8 months) and recurrent aortobronchial fistulas 5 months and 9 years after the initial procedure-resulting in a total of 41 endovascular procedures. The 30-day mortality rate was 8% (3 of 37) and the overall follow-up was 29.9 ± 36.6 months (range 0-139 months). All patients with traumatic ruptures demonstrated an immediate sealing of bleeding. Patients with aortobronchial fistulas also demonstrated a

  15. Treatment of carotid siphon aneurysms by use of the Willis stent graft: an angiographic and histopathological study

    International Nuclear Information System (INIS)

    Zhu, Yue-Qi; Li, Ming-Hua; Xie, Jian; Tan, Hua-Qiao; Wang, Jian-Bo; Cheng, Ying-Sheng

    2010-01-01

    We designed a carotid siphon (CS) aneurysm model in dogs to test a new stent graft (the Willis covered stent) and compared tissue reaction over 12-month follow-up versus a comparison group with stents implanted in straight vessels. Twenty-four saccular sidewall aneurysms (group A) and 12 CS aneurysms (group B) were created surgically. A Willis stent graft was implanted in each aneurysm. Angiography was performed immediately and at 1-, 3-, 6- and 12-month post-implantation to investigate aneurysm isolation, endoleak, stent angulation, parent artery (PA) patency and restenosis. Light and scanning electron microscopy were used to identify aneurysmal sac thrombi, intima hyperplasia and endothelial progress. Immediate angiography demonstrated mild endoleak in two aneurysms and three stent angulations in group B. Follow-up at 12 months revealed resolved endoleaks, occlusion in one PA and mild stenosis in three in group B. In group A, occlusion occurred in one PA and mild stenosis in two. Light microscopy revealed new intima, and all aneurysm sacs were filled with thrombi. In group B, endothelial progress was complete at 12 months, and closely correlated with haemodynamic changes. Application of a Willis stent graft is a feasible method of treating CS aneurysms, and it exhibits a prolonged endothelial progress compared with that in straight vessels. (orig.)

  16. Early experience with the multilayer aneurysm repair stent in the endovascular treatment of trans/infragenicular popliteal artery aneurysms: a mixed bag.

    Science.gov (United States)

    Thakar, Tejal; Chaudhuri, Arindam

    2013-06-01

    To present a preliminary experience using a multilayer flow-modulating stent for trans/infragenicular popliteal endovascular aneurysm repair. Five men (mean age 76 years, range 62-86) with 6 popliteal artery aneurysms (PAAs) measuring 22 to 39 mm in diameter (mean 30) underwent endovascular repair using the Cardiatis Multilayer Aneurysm Repair System (MARS) between June and August 2011. Radiological assessments post procedure using duplex ultrasonography and biplanar knee radiographs (additional contrast studies as necessary) sought evidence of aneurysm exclusion, graft patency, and preservation of branches and runoff vessels. Technical success was achieved in each case. There was one symptomatic stent occlusion requiring thrombectomy at 4 days, with reocclusion, and one leak via the stent struts into the sac with no branch outflow identified. Two further symptomatic stent occlusions were identified within a 6-week follow-up period, totaling 3 occlusions among the 6 devices deployed. No firm conclusion can be reached on the efficacy of the MARS in PAAs due to the inherent limitations of this small series, although a 50% thrombosis rate is a poor outcome. The risk of early thrombosis in flow-modulating stents deployed in the popliteal artery exists, as it does with earlier generation stent-grafts. Larger prospective trials and the influence of more aggressive antithrombotic/anticoagulant therapy should be considered to enable accurate evaluation of this device in popliteal artery aneurysms.

  17. Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Koike, Yuya, E-mail: r06118@hotmail.co.jp; Nishimura, Jun-ichi, E-mail: jun-ichi-n@nifty.com; Hase, Soichiro, E-mail: haseman@hotmail.co.jp; Yamasaki, Motoshige, E-mail: genyamasaki@gmail.com [Kawasaki Saiwai Hospital, Department of Interventional Radiology (Japan)

    2015-04-15

    PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasation of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.

  18. Femoro-Supragenicular Popliteal Bypass with a Bridging Stent Graft in a Diffusely Diseased Distal Target Popliteal Artery: Alternative to Below-Knee Popliteal Polytetrafluoroethylene Bypass

    Directory of Open Access Journals (Sweden)

    Joung Hun Byun

    2017-10-01

    Full Text Available Background: Lesions in distal target arteries hinder surgical bypass procedures in patients with peripheral arterial occlusive disease. Methods: Between April 2012 and October 2015, 16 patients (18 limbs with lifestyle- limiting claudication (n=12 or chronic critical limb ischemia (n=6 underwent femoral–above-knee (AK polytetrafluoroethylene (PTFE bypass grafts with a bridging stent graft placement between the distal target popliteal artery and the PTFE graft. Ring-supported PTFE grafts were used in all patients with no available vein for graft material. Follow-up evaluations assessed clinical symptoms, the ankle-brachial index, ultrasonographic imaging and/or computed tomography angiography, the primary patency rate, and complications. Results: All procedures were successful. The mean follow-up was 12.6 months (range, 11 to 14 months, and there were no major complications. The median baseline ankle-brachial index of 0.4 (range, 0.2 to 0.55 significantly increased to 0.8 (range, 0.5 to 1.0 at 12 months (p<0.01. The primary patency rate at 12 months was 83.3%. The presenting symptoms resolved within 2 weeks. Conclusion: In AK bypasses with a diffusely diseased distal target popliteal artery or when below-knee (BK bypass surgery is impossible, this procedure could be clinically effective and safe when used as an alternative to femoral-BK bypass surgery.

  19. Distal Marginal Stenosis: A Contributing Factor in Delayed Carotid Occlusion of a Patient With Carotid Blowout Syndrome Treated With Stent Grafts

    Directory of Open Access Journals (Sweden)

    Feng-Chi Chang

    2010-05-01

    Full Text Available Distal marginal stenosis is rarely reported to be a factor associated with poor long-term patency of patients of head and neck cancers with carotid blowout syndrome treated with stent grafts. We report a case of laryngeal cancer with rupture of the right common carotid artery. A self-expandable stent graft was deployed, but bleeding recurred. Another stent graft was deployed for the pseudoaneurysm located distal to the first stent graft. Rebleeding occurred because of pseudoaneurysm formation from reconstituted branches of the right superior thyroid artery. We performed direct percutaneous puncture of the proximal superior thyroid artery for successful embolization. Distal marginal stenosis and asymptomatic thrombosis of the carotid artery were noted at 3.5- and 5-month follow-ups, respectively. We suggest aggressive early follow-up and reintervention for distal marginal stenosis by combined antibiotic therapy and angioplasty and stenting to improve the long-term patency of stent-graft deployment for management of carotid blowout syndrome.

  20. Endovascular graft exclusion in treating thoracic aortic dissection: a report of 25 cases

    International Nuclear Information System (INIS)

    Chen Wei; Yang Jianyong; Zhuang Wenquan; Guo Wenbo; Li Heping; Zhong Lizhen; Huang Qiuping

    2003-01-01

    Objective: To evaluate the usefulness and efficacy of endovascular graft exclusion (EVGE) in treating thoracic aortic dissection (TAD). Methods: Twenty-five cases of TAD, including 24 cases of Standford B and 1 case of A, were treated by EVGE. The clinical outcome and morphological changes of the lesions were analyzed during a 2-20 months' follow-up. Results: Procedures were technically successful in all 25 cases, while a total of 28 stent-grafts were deployed (3 cases with 2 stent-grafts in each). Complete disappearance of the false lumen or remarkable decrease of the endoleak was noted on the angiograms after stent placement. No severe procedure-related complication was observed, and thrombosis of the false lumen was noted during the follow-up. Conclusion: EVGE is effective and reliable in treating TAD, especially for patients with sub-acute or chronic courses

  1. Treatment of carotid-siphon aneurysms by using willis stent-graft: an angiographic and histopathologic study in dogs

    International Nuclear Information System (INIS)

    Zhu Yueqi; Li Minghua; Xie Jian; Tan Huaqiao; Cheng Yingsheng; Wang Jianbo

    2010-01-01

    Objective: To establish a carotid siphon aneurysm model in dogs in order to test the mechanical features of a newly-designed Willis covered stent-graft and to investigate the histological reaction of the stent-implanted vessel during a follow-up period of 12 months. Methods: Twenty-four saccular sidewall aneurysms were surgically created in twelve dogs (group A) and 12 carotid siphon aneurysms in another twelve dogs (group B). A Willis stent-graft was implanted in each aneurysm. Angiography was performed immediately after the procedure and 1, 3, 6 and 12 months after the implantation to investigate the aneurysm isolation, endoleak, stent angulation, and the patency or restenosis of the parent artery. Light and scanning electronic microscopy were used to identify aneurysmal sac thrombi, intima hyperplasia and endothelial progress of the stent-loaded arterial segment. Results: In group B, postoperative immediate angiography demonstrated that two aneurysms had mild endoleak and three stents became angulated. Follow-up exam 12 months after the procedure revealed that all previous endoleaks disappeared, one parent artery became occluded and three parent arteries developed mild stenosis (< 50%). In group A, occlusion of parent artery was seen in one and mild stenosis (< 50%) in 2 cases. Electronic microscopy revealed new intima formation in all stents, and all aneurysmal sacs were filled with thrombi. In group B, the endothelialization process was not completed until 12 months after the stent implantation, and a marked correlation existed between endothelial cell arrangement and the hemodynamic orientation. Conclusion: It is feasible to treat carotid-siphon aneurysm in dog with a Willis stent-graft. The complete endothelialization of the covered stent in tortuous vessel takes longer time than that in rather straight vessel. (authors)

  2. Successful treatment of an iatrogenic hepatic arteriobiliary fistula with an endobiliary covered stent graft: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Song, Hyun; Lee, Su Lim; Ku, Young Mi; Chun, Chang Woo [The Catholic Univ. of Korea, Uijeongbu (Korea, Republic of)

    2012-07-15

    Hepatic arteriobiliary fistula is a rare cause of hemobilia following percutaneous transhepatic biliary drainage for treatment of hilar cholangiocarcinoma. Hemobilia related to arterial injury is resistant to conservative treatment. Therefore, transarterial embolization after confirmation of bleeding vessels on an angiogram is generally considered as the first line of treatment to stop arterial bleeding. However, in high risk situations such as a hepatic infarction by arterial embolization, the endobiliary approach with a covered stent can be considered as an alternative treatment method. The authors report a case of iatrogenic arteriobiliary fistula in a patient with hilar cholangiocarcinoma which was successfully controlled by an endobiliary covered stent graft.

  3. Role of graft oversizing in the fixation strength of barbed endovascular grafts.

    Science.gov (United States)

    Kratzberg, Jarin A; Golzarian, Jafar; Raghavan, Madhavan L

    2009-06-01

    The role of endovascular graft oversizing on risk of distal graft migration following endovascular aneurysm repair for abdominal aortic aneurysm is poorly understood. A controlled in vitro investigation of the role of oversizing in graft-aorta attachment strength for endovascular grafts (EVGs) with barbs was performed. Barbed stent grafts (N = 20) with controlled graft oversizing varying from 4-45% were fabricated while maintaining other design variables unchanged. A flow loop with physiological flow characteristics and a biosynthetic aortic aneurysm phantom (synthetic aneurysm model with a bovine aortic neck) were developed. The stent grafts were deployed into the aortic neck of the bio-synthetic aortic aneurysm phantom under realistic flow conditions. Computed tomography imaging of the graft-aorta complex was used to document attachment characteristics such as graft apposition, number of barbs penetrated, and penetration depth and angle. The strength of graft attachment to the aortic neck was assessed using mechanical pullout testing. Stent grafts were categorized into four groups based on oversizing: 4-10%; 11-20%; 21-30%; and greater than 30% oversizing. Pullout force, a measure of post-deployment fixation strength was not different between 4-10% (6.23 +/- 1.90 N), 11-20% (6.25 +/- 1.84 N) and 20-30% (5.85 +/- 1.89 N) groups, but significantly lower for the group with greater than 30% oversizing (3.67 +/- 1.41 N). Increasing oversizing caused a proportional decrease in the number of barbs penetrating the aortic wall (correlation = -0.83). Of the 14 barbs available in the stent graft, 89% of the barbs (12.5 of 14 on average) penetrated the aortic wall in the 4-10% oversizing group while only 38% (5.25 of 14) did for the greater than 30% group (P barb penetration were found to be positively correlated to pullout force. Greater than 30% graft oversizing affects both barb penetration and graft apposition adversely resulting in a low pullout force in this in vitro

  4. Anastomotic pseudoaneurysms after surgical reconstruction: Outcomes after endovascular repair of symptomatic versus asymptomatic patients

    International Nuclear Information System (INIS)

    Nolz, Richard; Gschwendtner, Manfred; Jülg, Gregor; Plank, Christina; Beitzke, Dietrich; Teufelsbauer, Harald; Wibmer, Andreas; Kretschmer, Georg; Lammer, Johannes

    2012-01-01

    Purpose: To compare perioperative and follow-up outcomes of symptomatic versus asymptomatic patients following endovascular repair of anastomotic pseudoaneurysms (APAs) of the abdominal aorta and iliac arteries. Methods: We retrospectively evaluated 17 patients (two women), with a mean age of 66.2 years (range 30–83 years). Endovascular treatment was performed in ten symptomatic, and seven asymptomatic patients electively. Data included technical success, perioperative (within 30 days) mortality and morbidity, as well as stent graft-related complications, reinterventions, and survival in follow-up. Results: Bifurcated (n = 13), aortomonoiliac (n = 3) endoprosthesis and one aortic cuff were implanted with a primary technical success rate of 100%. The overall in-hospital mortality and morbidity rate was 11.8% and 35.3%. The mean survival was 36.5 (range 0–111) months. There was a clear trend toward a lower overall survival within hospital and at one and three years for symptomatic patients compared to asymptomatic patients. (47.7 (CI: 0–138.8) versus 52.6 (CI: 28.5–76.8) months (p = 0.274)). During follow-up, late stent graft related complications were observed in six patients (35.3%) necessitating eight endovascular reinterventions. Additional three patients with primary fistulas between the APA and the intestine were treated by late surgical revision. Conclusion: Endovascular therapy of APAs represents a considerable alternative to open surgical repair. Short proximal anchoring zones still pose a risk for endoleaks and unintentional overstenting of side branches with commercially available devices, but this might be overcome by use of fenestrated and branched stent grafts in elective cases.

  5. Radial force measurement of endovascular stents: Influence of stent design and diameter.

    Science.gov (United States)

    Matsumoto, Takuya; Matsubara, Yutaka; Aoyagi, Yukihiko; Matsuda, Daisuke; Okadome, Jun; Morisaki, Koichi; Inoue, Kentarou; Tanaka, Shinichi; Ohkusa, Tomoko; Maehara, Yoshihiko

    2016-04-01

    Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P stents was greater than that of all three endovascular stents (P stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient. © The Author(s) 2015.

  6. Endovascular aortic graft infection resulting in retroperitoneal abscess: report of a case

    Directory of Open Access Journals (Sweden)

    Salvatore Di Somma

    2010-06-01

    Full Text Available Infection is a rare complication of aortoiliac endovascular procedures, with an incidence inferior to 0.5%, and it may result in a retroperitoneal abscess potentially evolving to sepsis and gastrointestinal bleeding. In more than 50% of cases endovascular aortoiliac prosthetic grafts infection occur months or years after the procedure. The growing number of endovascular procedures, and as the actually midterm follow up in most cases, septic sequelae will no doubt continue to occur with increased frequency and may represent an emerging problem in the ED for the emergency physician. Endovascular graft infection begins with unspecific clinical manifestations. An high index of suspicion in any patient with an aortic stent graft presenting prolonged or recurrent fever and or abdominal or back pain and a low threshold for obtaining CT scan should increase the clinician’s ability to make a timely diagnosis in the ED setting.

  7. Technical and clinical success of infrarenal endovascular abdominal aortic aneurysm repair: A 10-year single-center experience

    International Nuclear Information System (INIS)

    Steingruber, I.E.; Neuhauser, B.; Seiler, R.; Greiner, A.; Chemelli, A.; Kopf, H.; Walch, C.; Waldenberger, P.; Jaschke, W.; Czermak, B.

    2006-01-01

    Objective: The aim of our retrospective study was to review our single-center experience with aortic abdominal aneurysm (AAA) repair retrospectively. Material and methods: From 1995 to 2005, 70 consecutive patients affected by AAA were treated by endovascular stent-graft repair. Mean follow-up was 23.9 months. Follow-up investigations were performed at 6 and 12 months and yearly thereafter. Five different stent-graft designs were compared to each other. Primary technical success (PTS), assisted primary technical success (APTS), primary clinical success (PCS) and secondary clinical success (SCS) were evaluated. Results: All over PTS was achieved in 94.3%, APTS in 97.1%, PCS in 61.4%, APCS in 64.3% and SCS in 70%. There were 3 type I endoleaks, 25 type II endoleaks, 4 type III endoleaks, 8 limb problems, 5 conversions to open surgery, 10 aneurysm sac expansions and 14 device migrations. Patients with newer generation devices showed better results than patients with first generation prosthesis. In addition results were better for grafts with suprarenal fixation (versus infrarenal fixation) and grafts with barbs and hooks (versus grafts without barbs and hooks). Patients with bad anatomic preconditions showed a higher complication rate. Conclusion: Contrary to first generation products, new stent-graft designs show acceptable technical and clinical results in endovascular AAA aneurysm repair. However, this therapy still should be reserved only for patients with significant comorbities and suitable anatomic conditions

  8. Technical and clinical success of infrarenal endovascular abdominal aortic aneurysm repair: A 10-year single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Steingruber, I.E. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria)]. E-mail: iris.steingruber@uibk.ac.at; Neuhauser, B. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Seiler, R. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Greiner, A. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Chemelli, A. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Kopf, H. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Walch, C. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Waldenberger, P. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Jaschke, W. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Czermak, B. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria)

    2006-09-15

    Objective: The aim of our retrospective study was to review our single-center experience with aortic abdominal aneurysm (AAA) repair retrospectively. Material and methods: From 1995 to 2005, 70 consecutive patients affected by AAA were treated by endovascular stent-graft repair. Mean follow-up was 23.9 months. Follow-up investigations were performed at 6 and 12 months and yearly thereafter. Five different stent-graft designs were compared to each other. Primary technical success (PTS), assisted primary technical success (APTS), primary clinical success (PCS) and secondary clinical success (SCS) were evaluated. Results: All over PTS was achieved in 94.3%, APTS in 97.1%, PCS in 61.4%, APCS in 64.3% and SCS in 70%. There were 3 type I endoleaks, 25 type II endoleaks, 4 type III endoleaks, 8 limb problems, 5 conversions to open surgery, 10 aneurysm sac expansions and 14 device migrations. Patients with newer generation devices showed better results than patients with first generation prosthesis. In addition results were better for grafts with suprarenal fixation (versus infrarenal fixation) and grafts with barbs and hooks (versus grafts without barbs and hooks). Patients with bad anatomic preconditions showed a higher complication rate. Conclusion: Contrary to first generation products, new stent-graft designs show acceptable technical and clinical results in endovascular AAA aneurysm repair. However, this therapy still should be reserved only for patients with significant comorbities and suitable anatomic conditions.

  9. Unstable patients with retroperitoneal vascular trauma: an endovascular approach.

    Science.gov (United States)

    Boufi, Mourad; Bordon, Sébastien; Dona, Bianca; Hartung, Olivier; Sarran, Anthony; Nadeau, Sébastien; Maurin, Charlotte; Alimi, Yves S

    2011-04-01

    In hemodynamically unstable patients, the management of retroperitoneal vascular trauma is both difficult and challenging. Endovascular techniques have become an alternative to surgery in several trauma centers. Between 2004 and 2006, 16 patients (nine men, mean age: 46 years, range: 19-79 years) with retroperitoneal vascular trauma and hemodynamic instability were treated using an endovascular approach. The mean injury severity score was 30.7 ± 13.1. Mean systolic blood pressure and the shock index were 74 mm Hg and 1.9, respectively. Vasopressor drugs were required in 68.7% of cases (n = 11). Injuries were attributable to road traffic accidents (n = 15) and falls (n = 1). The hemorrhage sites included the internal iliac artery or its branches (n = 12) with bilateral injury in one case, renal artery (n = 2), abdominal aorta (n = 1), and lumbar artery (n = 1). In all, 14 coil embolizations and three stent-grafts were implanted. The technical success rate was 75%, as early re-embolization was necessary in one case and three patients died during the perioperative period. Six patients died during the period of hospitalization (37.5%). No surgical conversion or major morbidity was reported. In comparison with particulates, coil ± stent-graft may provide similar efficacy with regard to survival, and thus may be a valuable solution when particulate embolization is not available or feasible. Copyright © 2011 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  10. Endovascular Placement of an Extraluminal Femoropopliteal Bypass Graft in Human Cadavers

    International Nuclear Information System (INIS)

    Maynar, Manuel; Llorens, Rafael; Lopez-Sanchez, Carmen; Garcia-Martinez, Virginio; Qian Zhong; Lopera, Jorge; Castaneda, Wilfrido R.

    2005-01-01

    Purpose. A method to create an extraluminal femoropopliteal bypass graft using endovascular techniques was evaluated in situ on cadaver extremities in an attempt to develop a minimally invasive alternative technique for the management of infrainguinal occlusive arterial disease. Methods. The endovascular placement of an extraluminal femoropopliteal bypass graft was undertaken in 5 cadaver legs. Following percutaneous access to the popliteal artery (PA) or common femoral artery (CFA), a Rosch-Uchida needle was used to perforate the vascular wall, followed by the creation of an extraluminal tract using a looped wire and catheter. Once the desired level was reached the needle was again used to perforate the vascular wall of the proximal superficial femoral artery (SFA) or PA depending on the access used. Self-expanding expanded polytetrafluoroethylene (ePTFE) stent-grafts were then deployed to establish the extraluminal femoropopliteal bypass connecting the two arterial puncture sites. Following dilatation of the stent-graft, angiography was performed to assess the endoprostheses and to look for contrast leaks. Results. Technical success was achieved in all 5 legs. Procedure time varied from 15 to 30 min. The angiographic studies performed immediately after completion of the bypass procedure showed patency of the grafts with no evidence of kinking or leakage in any of the cases. Conclusion. This study has proved that the endovascular placement of an extraluminal femoropopliteal bypass graft in human cadaver legs using endovascular techniques under fluoroscopic control is technically feasible

  11. Emergency Endovascular Treatment of an Acute Traumatic Rupture of the Thoracic Aorta Complicated by a Distal Low-Flow Syndrome

    International Nuclear Information System (INIS)

    Bruninx, Guy; Wery, Didier; Dubois, Eric; El Nakadi, Badih; Dueren, Eric van; Verhelst, Guy; Delcour, Christian

    1999-01-01

    We report the case of a patient who suffered major trauma following a motorcycle accident that resulted in multiple fractures, bilateral hemopneumothorax, pulmonary contusions, and an isthmic rupture of the aorta with a pseudoaneurysm compressing the descending aorta. This compression was responsible for distal hypotension and low flow, leading to acute renal insufficiency and massive rhabdomyolysis. Due to the critical clinical status of the patient, which prevented any type of open thoracic surgery, endovascular treatment was performed. An initial stent-graft permitted alleviation of the compression and the re-establishment of normal hemodynamic conditions, but its low position did not allow sufficient coverage of the rupture. A second stent-graft permitted total exclusion of the pseudoaneurysm while preserving the patency of the left subclavian artery

  12. Predictors of aortic growth in uncomplicated type B aortic dissection from the Acute Dissection Stent Grafting or Best Medical Treatment (ADSORB) database

    DEFF Research Database (Denmark)

    Kamman, Arnoud V; Brunkwall, Jan; Verhoeven, Eric L

    2017-01-01

    BACKGROUND: The high-risk patient cohort of uncomplicated type B aortic dissections (uTBADs) needs to be clarified. We compared uTBAD patients treated with best medical treatment (BMT), with and without aortic growth, from the Acute Dissection Stent Grafting or Best Medical Treatment (ADSORB) tri...

  13. Accidental Coverage of Both Renal Arteries during Infrarenal Aortic Stent-Graft Implantation: Cause and Treatment

    Directory of Open Access Journals (Sweden)

    Umberto Marcello Bracale

    2014-01-01

    Full Text Available The purpose of this paper is to report a salvage maneuver for accidental coverage of both renal arteries during endovascular aneurysm repair (EVAR of an infrarenal abdominal aortic aneurysm (AAA. A 72-year-old female with a 6 cm infrarenal abdominal aortic aneurysm was treated by endovascular means with a standard bifurcated graft. Upon completing an angiogram, both renal arteries were found to be accidentally occluded. Through a left percutaneous brachial approach, the right renal artery was catheterized and a chimney stent was deployed; however this was not possible for the left renal artery. A retroperitoneal surgical approach was therefore carried out with a retrograde chimney stent implanted to restore blood flow. After three months, both renal arteries were patent and renal function was not different from the baseline. Both endovascular with percutaneous access via the brachial artery and open retroperitoneal approaches with retrograde catheterization are feasible rescue techniques to recanalize the accidentally occluded renal arteries during EVAR.

  14. Type 1a endoleak following Zone 1 and Zone 2 thoracic endovascular aortic repair: effect of bird-beak configuration.

    Science.gov (United States)

    Kudo, Tomoaki; Kuratani, Toru; Shimamura, Kazuo; Sakamoto, Tomohiko; Kin, Keiwa; Masada, Kenta; Shijo, Takayuki; Torikai, Kei; Maeda, Koichi; Sawa, Yoshiki

    2017-10-01

    Type 1a endoleak is one of the most severe complications after thoracic endovascular aortic repair (TEVAR), because it carries the risk of aortic rupture. The association between bird-beak configuration and Type 1a endoleak remains unclear. The purpose of this study was to analyse the predictors of Type 1a endoleak following Zone 1 and Zone 2 TEVAR, with a particular focus on the effect of bird-beak configuration. From April 2008 to July 2015, 105 patients (mean age 68.6 years) who underwent Zone 1 and 2 landing TEVAR were enrolled, with a mean follow-up period of 4.3 years. The patients were categorized into 2 groups, according to the presence (Group B, n = 32) or the absence (Group N, n = 73) of bird-beak configuration on the first postoperative multidetector computed tomography. The Kaplan-Meier event-free rate curve showed that Type 1a endoleak and bird-beak progression occurred less frequently in Group N than in Group B. Five-year freedom from Type 1a endoleak rates were 79.7% and 100% for Groups B and N, respectively (P = 0.007). Multivariable logistic regression analysis showed that dissecting aortic aneurysm (odds ratio 3.72, 95% confidence interval 1.30-11.0; P = 0.014) and shorter radius of inner curvature (odds ratio 1.09, 95% confidence interval 0.85-0.99; P = 0.025) were significant risk factors for bird-beak configuration. Multivariable Cox proportional hazard regression showed that Z-type stent graft (hazard ratio 2.69, 95% confidence interval 1.11-6.51; P = 0.030) was a significant risk factor for bird-beak progression. Appropriate stent grafts need to be chosen carefully to prevent Type 1a endoleak and bird-beak configuration after landing Zone 1 and 2 TEVAR. Patients with bird-beak configuration on early postoperative multidetector computed tomography require closer follow-up to screen for Type 1a endoleak. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio

  15. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Zhonghua; Chaichana, Thanapong [Curtin University of Technology, Perth (Australia)

    2010-02-15

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair.

  16. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    International Nuclear Information System (INIS)

    Sun, Zhonghua; Chaichana, Thanapong

    2010-01-01

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair

  17. JAG Tearing Technique with Radiofrequency Guide Wire for Aortic Fenestration in Thoracic Endovascular Aneurysm Repair

    International Nuclear Information System (INIS)

    Ricci, Carmelo; Ceccherini, Claudio; Leonini, Sara; Cini, Marco; Vigni, Francesco; Neri, Eugenio; Tucci, Enrico; Benvenuti, Antonio; Tommasino, Giulio; Sassi, Carlo

    2012-01-01

    An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided in two parts by an intimal flap. The proximal landing zone was suitable to place a thoracic stent graft. The distal landing zone was created by cutting the intimal flap in the distal third of the descending thoracic aorta with a radiofrequency guide wire and intravascular ultrasound catheter.

  18. Thoracic aortic stent-graft placement combined with left subclavian artery 'chimney operation': therapeutic analysis of 15 cases with insufficient proximal anchor area

    International Nuclear Information System (INIS)

    Liu Jiayi; Huang Lianjun; Fan Zhanming; Zhang Zhaoqi

    2012-01-01

    Objective: To discuss the strategies for the management of insufficient proximal anchoring area during the performance of transluminal stent-graft placement (TSGP), and to evaluate the feasibility of intentional coverage of the left subclavian artery (LSA) together with left subclavian artery stent-graft placement by using 'chimney operation' technique. Methods: A total of 15 patients with thoracic aortic diseases complicated by insufficient proximal anchoring area, who were encountered in authors' hospital during the period from Dec. 2009 to April 2011, were enrolled in this study. The clinical data were retrospectively analyzed. The thoracic aortic diseases included aortic dissection (n=6), aortic pseudoaneurysm (n=1), aortic aneurysm (n=4) and penetrating ulcer (n=4). Of the 15 patients, the distance between the lesion and LSA anchoring site 15 mm in 2. TSGP was carried out. The ostium of LSA was intentionally and completely covered by thoracic aortic stent-graft and left subclavian artery stent-graft placement was subsequently performed. The patients were kept under observation for symptoms of cerebral and upper limb ischemia. The postoperative complications such as endoleak and the patency of LSA were assessed with angiography. Results: Thoracic aortic stent-graft placement was successfully carried out in all 15 patients. In addition, one 'chimney' stent was properly implanted in LSA in each patient. After the procedure, no complications of nervous system or severe ischemia of upper extremity occurred. Follow-up examinations performed between 5 days to 3 months after the treatment revealed that the aortic stent-graft remained in stable condition and no type Ⅰ endoleak occurred, meanwhile the blood flow in 'chimney' stent was unobstructed. Conclusion: Intentional LSA coverage with 'chimney operation' can expand the applicability of TSGP with high tolerability. It is especially useful for patients with left vertebral artery blood supply dominance or with

  19. New Technique for the Preservation of the Left Common Carotid Artery in Zone 2a Endovascular Repair of Thoracic Aortic Aneurysm

    International Nuclear Information System (INIS)

    Juszkat, Robert; Kulesza, Jerzy; Zarzecka, Anna; Jemielity, Marek; Staniszewski, Ryszard; Majewski, Wacław

    2011-01-01

    To describe a technique for the preservation of the left common carotid artery (CCA) in zone 2 endovascular repair of thoracic aortic aneurysm. This technique involves the placement of a guide wire into the left CCA via the right brachial artery before stent graft deployment to enable precise visualization and protection of the left CCA during the whole procedure. Of the 107 patients with thoracic endovascular aortic repair in our study, 32 (30%) had the left subclavian artery intentionally covered (landing zone 2). Eight (25%) of those 32 had landing zone 2a—the segment distally the origin of the left CCA, halfway between the origin of the left CCA and the left subclavian artery. In all patients, a guide wire was positioned into the left CCA via the right brachial artery before stent graft deployment. It is a retrospective study in design. In seven patients, stent grafts were positioned precisely. In the remaining patient, the positioning was imprecise; the origin of the left CCA was partially covered by the graft. A stent was implanted into the left CCA to restore the flow into the vessel. All procedures were performed successfully. The technique of placing a guide wire into the left CCA via the right brachial artery before stent graft deployment is a safe and effective method that enables the precise visualization of the left CCA during the whole procedure. Moreover, in case of inadvertent complete or partial coverage of the origin of the left CCA, it supplies safe and quick access to the artery for stent implantation.

  20. Dynamic Geometric Analysis of the Renal Arteries and Aorta following Complex Endovascular Aneurysm Repair.

    Science.gov (United States)

    Ullery, Brant W; Suh, Ga-Young; Kim, John J; Lee, Jason T; Dalman, Ronald L; Cheng, Christopher P

    2017-08-01

    Aneurysm regression and target vessel patency during early and mid-term follow-up may be related to the effect of stent-graft configuration on the anatomy. We quantified geometry and remodeling of the renal arteries and aneurysm following fenestrated (F-) or snorkel/chimney (Sn-) endovascular aneurysm repair (EVAR). Twenty-nine patients (mean age, 76.8 ± 7.8 years) treated with F- or Sn-EVAR underwent computed tomography angiography at preop, postop, and follow-up. Three-dimensional geometric models of the aorta and renal arteries were constructed. Renal branch angle was defined relative to the plane orthogonal to the aorta. End-stent angle was defined as the angulation between the stent and native distal artery. Aortic volumes were computed for the whole aorta, lumen, and their difference (excluded lumen). Renal patency, reintervention, early mortality, postoperative renal impairment, and endoleak were reviewed. From preop to postop, F-renal branches angled upward, Sn-renal branches angled downward (P renals exhibited increased end-stent angulation (12 ± 15°, P renals, whereas F-renals exhibited increased end-stent angulation (5 ± 10°, P renal stent patency was 94.1% and renal impairment occurred in 2 patients (6.7%). Although F- and Sn-EVAR resulted in significant, and opposite, changes to renal branch angle, only Sn-EVAR resulted in significant end-stent angulation increase. Longitudinal geometric analysis suggests that these anatomic alterations are primarily generated early as a consequence of the procedure itself and, although persistent, they show no evidence of continued significant change during the subsequent postoperative follow-up period. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Mid-term outcomes of endovascular aortic aneurysm repair with carbon dioxide-guided angiography.

    Science.gov (United States)

    Takeuchi, Yuriko; Morikage, Noriyasu; Matsuno, Yutaro; Nakamura, Tamami; Samura, Makoto; Ueda, Koshiro; Harada, Takasuke; Ikeda, Yoshitaka; Suehiro, Kotaro; Ito, Hiroshi; Sakata, Kensuke; Hamano, Kimikazu

    2018-05-14

    Although iodinated contrast (IC) agents are commonly used in endovascular aneurysm repair (EVAR), perioperative use in patients with renal dysfunction or IC allergies is avoided. Carbon dioxide (CO 2 )-guided angiography is a promising alternative. We aimed to evaluate short-term and mid-term outcomes of EVAR using CO 2 -guided angiography. Three hundred and eighty-one patients who underwent EVAR from January 2012 to September 2016 were retrospectively reviewed and divided into an IC-EVAR group (n=351) and CO 2 -EVAR group (n=30). Subjects in the CO 2 -EVAR group had severe renal dysfunction (n=27) and IC allergy (n=4). Intraoperative, postoperative, and follow-up variables were compared. Compared to the IC-EVAR group, preoperative serum creatinine level was significantly higher (2.0 vs. 0.92 mg/dL, P < .0001) and mean IC dose significantly lower (18 vs. 55 mL P < .0001) in the CO 2 -EVAR group. The fluoroscopy time, operative time, number of stent grafts placed, and technical success rates of the groups were similar; no type I and/or type III endoleaks were detected on completion angiography. There was no acute kidney injury and one case of intestinal necrosis in the CO 2 -EVAR group, potentially due to cholesterol embolism. Postoperative endoleak, enlargement of aneurysms, survival, freedom from secondary intervention, and renal function change up to 3 months postoperatively were similar between groups. CO 2 -EVAR is technically feasible and exhibits prominent renal protection. However, consideration of the aortic lumen status remains an important challenge. Copyright © 2018. Published by Elsevier Inc.

  2. Morphological risk factors of stroke during thoracic endovascular aortic repair.

    Science.gov (United States)

    Kotelis, Drosos; Bischoff, Moritz S; Jobst, Bertram; von Tengg-Kobligk, Hendrik; Hinz, Ulf; Geisbüsch, Philipp; Böckler, Dittmar

    2012-12-01

    This study aims to identify independent factors correlating to an increased risk of perioperative stroke during thoracic endovascular aortic repair (TEVAR). A prospective maintained TEVAR database, medical records, and imaging studies of 300 patients (205 men; median age of all, 66 years, range 21-89), who underwent TEVAR between March 1997 and February 2011, were reviewed. Preoperative CT data sets were reviewed by two experienced radiologists with focus on the atheroma burden in the aortic arch (grade I, normal, to grade V, ulcerated or pedunculated atheroma). Aortic arch geometry (arch types I-III) was documented. Further parameters included in the univariate analysis were age, gender, urgency of repair, duration of procedure, adenosine-induced cardiac arrest or rapid pacing, proximal landing zone, left subclavian artery (LSA) coverage, and number of stent grafts. Multivariate logistic regression analysis was performed to assess the independent correlations of potential risk factors. Atherosclerotic aneurysm was the most common pathology (44%). One hundred and fifty-four of our patients (51%) were treated under urgent or emergent conditions. Seventeen percent of all patients had significant arch atheroma (grade IV or V), and 43% had a steep type III aortic arch. The perioperative stroke was 4% (12 patients; median age, 73 years, range 31-78). Two strokes were lethal (0.7%). All strokes were classified as embolic based on imaging characteristics. In eight patients, strokes were located in the left cerebral hemisphere (seven of them in the anterior and one in the posterior circulation). Four stroke patients (one in the left posterior circulation) underwent LSA coverage without revascularization. Three stroke patients had severe arch atheroma grade V. Five patients suffering stroke were recognized to have a type III aortic arch. Strokes were equally distributed between zones 0-2 vs. 3-4 (n = 6 each, 5 vs. 3.3%). The highest incidence was found in zone 1 (11

  3. Impact of contrast injection and stent-graft implantation on reproducibility of volume measurements in semiautomated segmentation of abdominal aortic aneurysm on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Morin-Roy, Florence; Hadjadj, Sofiane; Thomas, Olivier; Yang, Dan Yang [Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Notre-Dame, Department of Radiology, Montreal, Quebec (Canada); Kauffmann, Claude [University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada); Tang, An [University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada); Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Saint-Luc, Department of Radiology, Montreal, Quebec (Canada); Piche, Nicolas [Object Research System, Montreal, Quebec (Canada); Elkouri, Stephane [Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Hotel-Dieu, Department of Vascular surgery, Montreal, Quebec (Canada); Therasse, Eric [University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada); Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Hotel-Dieu, Department of Radiology, Montreal, Quebec (Canada); Soulez, Gilles [Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Notre-Dame, Department of Radiology, Montreal, Quebec (Canada); University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada)

    2014-07-15

    To assess the impact of contrast injection and stent-graft implantation on feasibility, accuracy, and reproducibility of abdominal aortic aneurysm (AAA) volume and maximal diameter (D-max) measurements using segmentation software. CT images of 80 subjects presenting AAA were divided into four equal groups: with or without contrast enhancement, and with or without stent-graft implantation. Semiautomated software was used to segment the aortic wall, once by an expert and twice by three readers. Volume and D-max reproducibility was estimated by intraclass correlation coefficients (ICC), and accuracy was estimated between the expert and the readers by mean relative errors. All segmentations were technically successful. The mean AAA volume was 167.0 ± 82.8 mL and the mean D-max 55.0 ± 10.6 mm. Inter- and intraobserver ICCs for volume and D-max measurements were greater than 0.99. Mean relative errors between readers varied between -1.8 ± 4.6 and 0.0 ± 3.6 mL. Mean relative errors in volume and D-max measurements between readers showed no significant difference between the four groups (P ≥ 0.2). The feasibility, accuracy, and reproducibility of AAA volume and D-max measurements using segmentation software were not affected by the absence of contrast injection or the presence of stent-graft. (orig.)

  4. Laser Fenestration of Aortic Stent-Grafts Followed by Noncompliant vs Cutting Balloon Dilation: A Scanning Electron Microscopy Study.

    Science.gov (United States)

    Lin, Jing; Parikh, Niraj; Udgiri, Naval; Wang, Shaoxia; Miller, Daniel F; Li, Chaojing; Panneton, Jean; Nutley, Mark; Zhang, Ze; Huang, Yunfan; Lu, Jun; Zhang, Jingyi; Wang, Lu; Guidoin, Robert

    2018-06-01

    To examine the effects of in situ laser fenestration and subsequent balloon dilation (noncompliant vs cutting) on the graft fabric of 4 aortic stent-graft models. In an in vitro setup, the Zenith TX2, Talent, Endurant, and Anaconda aortic stent-grafts (all made of polyester graft material) were subjected to laser fenestration with a 2.3-mm-diameter probe at low and high energy in a physiologic saline solution followed by balloon dilation of the hole. For the first series of tests, 6-mm-diameter noncompliant balloons were used and replaced for the second series by 6-mm-diameter cutting balloons. Each procedure was performed 5 times (5 fenestrations per balloon type). The fenestrations were examined visually and with light and scanning electron microscopy. Each fenestration demonstrated various degrees of fraying and/or tearing regardless of the device. The monofilament twill weave of the Talent endograft tore in the warp direction up to 7.09±0.46 mm at high energy compared with 2.41±0.26 mm for the Endurant multifilament device. The fenestrations of the 3 endografts with multifilament weave (Zenith, Anaconda, and Endurant) showed more fraying; fenestration areas in the multifilament Endurant were >10 mm 2 at low and high energy. The fenestrations were free of melted fibers, but minor blackening of the filaments was observed in all devices. Overall, the cutting balloons resulted in worse tearing and damage. Of note, the edges of the dilated laser-formed fenestrations of the Talent and the Endurant grafts demonstrated evidence of additional shredded yarns. In situ fenestration does not cause any melting of the polyester; however, the observed structural damage to the fabric construction must be carefully considered. Cutting balloons caused various levels of tearing compared to the noncompliant balloons and cannot be recommended for use in this application. Rather, noncompliant balloons should be employed, but only with endografts constructed from multifilament yarns

  5. The management of unimplantable stent during endovascular procedure:report of three cases

    International Nuclear Information System (INIS)

    Xiong Jiang; Wang Lijun; Guo Wei; Liu Xiaoping; Yin Tai; Jia Xin; Ma Xiaohui; Liu Meng; Zhang Hongpeng; Zhang Minhong

    2010-01-01

    Objective: To summarize the experience of dealing with the difficulty of the stent implantation encountered in the endovascular procedure. Methods: The causes of unimplantable stent encountered in the endovascular procedure included the delivery system entraping due to the stenosis and shrinking of peripheral self-expandable stent, the balloon expandable stent implantation and retrievement failure due to the rupture-balloon or stent edge opening, and the delivery system entraping due to aortic stent graft for aorta kinking. The balloon dilation for the stenosis and shrinking stent, the large caliber introducer sheath for removal of the rupture-balloon and edge opening, the expandable stent and balloon-assisted delivery system retrieve were used to solve the above three dilemma of unimplantable stent occurred in the endovascular procedure. Results: These three dilemma of stent unimplantable problem in the endovascular therapy were solved by endovascular method while little additional incision injury was added to the patients. Conclusion: For solving stent unimplantable problem the endovascular technique is the method of first choice, nevertherless, it is very important for the operator to be highly skilled in manipulating endovascular procedure. (authors)

  6. Evaluating the in situ loading and accelerated durability of barbs located on bifurcated aorto-iliac stent-grafts.

    Science.gov (United States)

    Conti, J C; Strope, E R

    2000-01-01

    A special three-part protocol has been generated for the isolated durability testing of stent barbs. This triple protocol includes an initial evaluation on a cardiovascular duplicator to determine the loading per barb that occurs during normal flow through the stent-graft. The next stage of this protocol determined the frequency response characteristics of the bending point where the barb attaches to the stent to allow for the determination of the appropriate frequency to carry out the accelerated testing. The final part of the test includes high speed bend testing at frequencies determined in the second part of the methods to determine the long term durability of the isolated barb stent unit. The results of this testing indicated that under normal cardiovascular conditions each barb is experiencing a loading of 20 grams peak during maximum forward flow. Loading the isolated barb/stent segment at 600 beats per minute (bpm) for 400 million cycles indicated no tendency for these barbs to experience a change in physical properties. During this testing there were no barbs that broke.

  7. Tratamento das afecções da aorta com a primeira geração de stents auto-expansíveis Aortic diseases treatment with a first generation of self expanding stent-grafts

    Directory of Open Access Journals (Sweden)

    Wagner Michael PEREIRA

    2001-09-01

    ,57%, com 70,15% dos pacientes livre de eventos em 33 meses de seguimento, tornando o método factível e diminuindo a mortalidade no tratamento cirúrgico das dissecções agudas e crônicas do tipo B.INTRODUCTION: The authors describe the implantation of an endovascular self-expanding stents grafts at 33 months of follow-up. The use can be a new alternative for the treatment of descending aortic dissections and aneurysms disease. MATERIAL AND METHODS: From April 1998 to November 2000 (32 months, 37 endovascular stent grafts were implanted, 21 in acute dissections type B, 7 in acute dissections type A and 9 in chronic dissections type B and aneurysms ones. The age varied between 39 and 79 years (mean=57.94 ± 1.91 years, considering that 64.86% were male patients. The patients were submitted to median esternotomy, extracorporeal circulation (ECC, with deep hipothermia (18-20ºC, total circulatory arrest (TCA, and retrograde cerebral perfusion (RCP. The transverse aorta was incised and the stent was implanted in the descending proximal aorta with the aid sometimes of aortoscopy. The times of ECC, aortic clamping, TCA, RCP, rewarming, mechanic ventilation, hospitalization, trans and post-operative bleeding, blood replacement, events curve and survival curve were analyzed. RESULTS: The hospital mortality (30 days was 13.51%; 32 have been followed up from 1 to 33 months, 70.7% are free of events and survival curve with 63.19% (33 months. CONCLUSIONS: The implant of self-expanding intraluminal stent grafts presented has lower hospital mortality in the acute phase and follow-up in acute aortic dissections type B (10% than clinical treatment (IRAD. In spite of the small sample the procedure is promising and needs longer follow-up.

  8. Zone zero thoracic endovascular aortic repair: A proposed modification to the classification of landing zones.

    Science.gov (United States)

    Roselli, Eric E; Idrees, Jay J; Johnston, Douglas R; Eagleton, Matthew J; Desai, Milind Y; Svensson, Lars G

    2018-04-01

    Endovascular stent-grafting provides an alternative treatment option for high-risk patients with ascending aortic disease. The feasibility of this approach has been demonstrated before. We assess the updated experience with ascending thoracic endovascular aortic repair and propose a modification of the landing zone classification based on the outcomes. From 2006 to 2016, 39 patients deemed very high risk for open replacement underwent endovascular repair of ascending aorta for acute type A dissection (12, 31%), intramural hematoma (2, 5%), pseudoaneurysm (22, 56%), and chronic dissection suture line entry tear (3, 8%). Ascending thoracic endovascular aortic repair was performed in 36 patients. In 3 patients with pseudoaneurysm, occluder devices were used. Computed tomography imaging analysis was performed, and the extent of aortic pathology was designated by segmental proximity to the left ventricle. Segmental anatomy of the proximal aorta was designed as zone 0A from the annulus to the distal margin of highest coronary, 0B extends from above the coronary to the distal margin of right pulmonary artery, and 0C extends from the right pulmonary artery border to the innominate artery. Multivariable time to event Cox regression analysis was performed to predict mortality, and long-term survival was estimated using the Kaplan-Meier method. Operative mortality was 13%; all 5 deaths occurred after emergency ascending thoracic endovascular aortic repair for type A dissection. Other complications included stroke in 4 patients (10%), myocardial infarction in 2 patients (5%), tracheostomy in 2 patients (5%), and dialysis in 2 patients (5%). In patients with acute type A dissection, the ascending pathology extended into zone 0A in 10 (71%) and 0B in 4 (29%). Among those with pseudoaneurysm, the location of the defect was in 0B in 11 (50%), 0C in 10 (45%), and 0A in 1. Among the patients with chronic dissection, the defect was located in 0C in all 3 (100%). After multivariable

  9. Endovascular Repair of Thoracoabdominal and Arch Aneurysms in Patients with Connective Tissue Disease Using Branched and Fenestrated Devices.

    Science.gov (United States)

    Clough, Rachel E; Martin-Gonzalez, Teresa; Van Calster, Katrien; Hertault, Adrien; Spear, Rafaëlle; Azzaoui, Richard; Sobocinski, Jonathan; Haulon, Stéphan

    2017-10-01

    Prophylactic open surgery is the standard practice in patients with connective tissue and thoracoabdominal aortic aneurysm (TAAA) and aortic arch disease. Branched and fenestrated devices offer a less invasive alternative but there are concerns regarding the durability of the repair and the effect of the stent graft on the fragile aortic wall. The aim of this study is to evaluate mid-term outcomes of fenestrated and/or branched endografting in patients with connective tissue disease. All patients with connective tissue disease who underwent TAAA or arch aneurysm repair using a fenestrated and/or branched endograft in a single, high-volume center between 2004 and 2015 were included. Ruptured aneurysms and acute aortic dissections were excluded from this study, but not chronic aortic dissections. In total, 427 (403 pararenal and TAAAs, and 24 arch aneurysms) endovascular interventions were performed during the study period. Of these, 17 patients (4%) (16 TAAAs, 1 arch) had connective tissue disease. All patients were classified as unfit for open repair. The mean age was 51 ± 8 years. Thirteen patients with TAAA were treated with a fenestrated, 1 with a branched, and 2 with a combined fenestrated/branch device. A double inner branch device was used to treat the arch aneurysm. The technical success rate was 100% with no incidence of early mortality, spinal cord ischemia, stroke, or further dissection. Postoperative deterioration in renal function was seen in 3 patients (18.8%) and no hemodialysis was required. The mean follow-up was 3.4 years (0.3-7.4). Aneurysm sac shrinkage was seen in 35% of patients (6/17) and the sac diameter remained stable in 65% of patients (11/17). No sac or sealing zone enlargement was observed in any of the patients and there were no conversions to open repair. Reintervention was required in 1 patient at 2 years for bilateral renal artery occlusion (successful fibrinolysis). One type II endoleak (lumbar) is under surveillance and 1 type

  10. Editor's Choice - Late Open Surgical Conversion after Endovascular Abdominal Aortic Aneurysm Repair.

    Science.gov (United States)

    Kansal, Vinay; Nagpal, Sudhir; Jetty, Prasad

    2018-02-01

    Late open surgical conversion following endovascular aneurysm repair (EVAR) may occur more frequently after performing EVAR in anatomy outside the instructions for use (IFU). This study reviews predictors and outcomes of late open surgical conversion for failed EVAR. This retrospective cohort study reviewed all EVARs performed at the Ottawa Hospital between January 1999 and May 2015. Open surgical conversions >1 month post EVAR were identified. Variables analysed included indication for conversion, pre-intervention AAA anatomy, endovascular device and configuration, operative technique, re-interventions, complications, and death. Of 1060 consecutive EVARs performed, 16 required late open surgical conversion. Endografts implanted were Medtronic Talent (n = 8, 50.0%), Medtronic Endurant (n = 3, 18.8%), Cook Zenith (n = 4, 25.0%), and Terumo Anaconda (n = 1, 6.2%). Eleven grafts were bifurcated (68.8%), five were aorto-uni-iliac (31.2%). The median time to open surgical conversion was 3.1 (IQR 1.0-5.2) years. There was no significant difference in pre-EVAR rupture status (1.4% elective, 2.1% ruptured, p = .54). Indications for conversion included: Type 1 endoleak with sac expansion (n = 4, 25.0%), Type 2 endoleak with expansion (n = 2, 12.5%), migration (n = 3, 18.8%), sac expansion without endoleak (n = 2, 12.5%), graft infection (n = 3, 18.8%), rupture (n = 2, 12.5%). Nine patients (56.2%) underwent stent graft explantation with in situ surgical graft reconstruction, seven had endograft preserving open surgical intervention. The 30 day mortality was 18.8% (n = 3, all of whom having had endograft preservation). Ten patients (62.5%) suffered major in hospital complications. One patient (6.5%) required post-conversion major surgical re-intervention. IFU adherence during initial EVAR was 43.8%, versus 79.0% (p Open surgical conversion following EVAR results in significant morbidity and mortality. IFU adherence of EVARs later requiring open surgical

  11. Aortic dissection. Basic aspects and endovascular management

    International Nuclear Information System (INIS)

    Jaramillo, Nicolas I; Alviar, Carlos I

    2005-01-01

    Treatment of thoracic aortic pathology is complicated by the morbidity associated to the surgical procedure and to the frailty of an elderly and difficult population. Surgical operation in this kind of population frequently bears a significant incidence of death and long-term disability. In an effort to reduce the incidence of negative outcomes, minimally invasive techniques in the form of endovascular stenting have been introduced during the past decade. The technology, originally described by Parodi, and initially designed for its use in abdominal aortic aneurysms, has been adapted for the treatment of thoracic aortic aneurysms. Furthermore, an improved understanding of the pathophysiology and the natural history of thoracic aortic disease as well as the analysis of the outcomes have facilitated our treatment decisions in terms of the timing for an appropriate intervention. Treatment of thoracic aortic dissection using endovascular Stent is one of the more recent advances in this condition and is receiving increasing attention, as it is a less invasive alternative to an open surgical repair. Although this technology is still innovative, significant improvements have been made lately in the design and deployment of the endovascular Stent-grafts. These prostheses have been increasingly used to treat aneurysms, dissections and traumatic ruptures, as well as giant penetrating ulcers and intramural hematomas of the descending thoracic aorta with good early and mid-term outcomes. The rareness, complexity and severity of the pathology and the theoretically high risk of complications should render the surgeon extremely cautious especially with young patients. Conceptually, the endo luminal treatment in the acute phase seems to be the solution and will probably become a preferred therapy while technical refinement is under way. Worldwide experience is growing and with this a better understanding of the indications and limitations of this innovative therapy will be

  12. Endovascular Treatment of Ruptured Abdominal Aortic Aneurysm with Aortocaval Fistula

    International Nuclear Information System (INIS)

    Guzzardi, Giuseppe; Fossaceca, Rita; Divenuto, Ignazio; Musiani, Antonello; Brustia, Piero; Carriero, Alessandro

    2010-01-01

    Aortocaval fistula (ACF) is a rare complication of abdominal aortic aneurysm (AAA). We report the endovascular repair of an AAA rupture into the inferior vena cava. A 78-year-old woman was admitted to our hospital for acute hypotension. She presented with a pulsatile abdominal mass and became rapidly anuric. Abdominal computed tomography (CT) showed an AAA rupture into the inferior vena cava. The features of the AAA made it suitable for endovascular repair. To prevent pulmonary embolism caused by the presence of sac thrombosis near the vena cava lumen, a temporary vena cava filter was deployed before the procedure. A bifurcated stent-graft was placed with the patient under local anaesthesia, and the AAA was successfully treated. A transient type II endoleak was detected on CT 3 days after endograft placement. At routine follow-up 6 and 12 months after the procedure, the patient was in good clinical condition, and the type II endoleak had sealed completely. Endovascular treatment offers an attractive therapeutic alternative to open repair in case of ACF; however, only small numbers of patients have been treated, and long-term follow-up interval is lacking.

  13. Perioperative management of endovascular abdominal aortic aneurysm repair

    International Nuclear Information System (INIS)

    Wang Haofu; Wang Yuwei; Li Jun; Zhao Zonggang; Qi Sen

    2010-01-01

    Objective: To summarize the clinical experience of perioperative management in performing endovascular abdominal aortic aneurysm repair (EVAR). Methods: EVAR was performed in 22 patients with abdominal aortic aneurysm. The clinical data were retrospectively analyzed. Before treatment the functions of main organs were evaluated and certain measures were adopted in order to protect them. Useful parameters, including the length, diameter, angle and configuration of the proximal and distal aneurysmal neck, the relationship of the aneurysm to aortic branches, the distance from the lowest renal artery to the bifurcation of abdominal aorta, and the quality of access vessels (such as diameter, tortuosity and calcification degree) were determined and assessed with CTA. According to the parameters thus obtained, the suitable stent-graft with ideal diameter and length was selected, and the optimal surgery pattern was employed. Local anesthesia was employed in 20 patients, among them the local anesthesia had to be changed to general anesthesia in one. Epidural anesthesia was carried out in one patient through the surgically-reconstructed iliac artery access,and general anesthesia was employed in one patient who had Stanford type A aortic dissection. The lowest renal artery must be accurately localized before deployment of stent-graft was started. At least one patent internal iliac artery should be reserved when bilateral internal iliac arteries needed to be covered, to be covered by stages or to be reconstructed. After stent-graft placement, angiography must be performed to find out if there was any endoleak and, if any, to determine the type of endoleak and to deal with it properly. Two cases had proximal type I endoleak, so balloon dilation was employed in one and cuff implantation in another one. Distal type I endoleak occurred in one case, but, unfortunately, the iliac artery ruptured when balloon dilation was employed, therefore the patient had to receive vascular repair

  14. Resolution of Large Azygos Vein Aneurysm Following Stent-Graft Shunt Placement in a Patient with Ehlers-Danlos Syndrome Type IV

    International Nuclear Information System (INIS)

    D'Souza, Estelle S.; Williams, David M.; Deeb, G.M.; Cwikiel, Wojciech

    2006-01-01

    Ehlers-Danlos syndrome (EDS) type IV is a rare connective tissue disorder associated with thin-walled, friable arteries and veins predisposing patients to aneurysm formation, dissection, fistula formation, and vessel rupture. Azygos vein aneurysm is an extremely rare condition which has not been reported in association with EDS in the literature. We present a patient with EDS type IV and interrupted inferior vena cava (IVC) with azygos continuation who developed an azygos vein aneurysm. In order to decrease flow through the azygos vein and reduce the risk of aneurysm rupture, a stent-graft shunt was created from the right hepatic vein to the azygos vein via a transhepatic, retroperitoneal route. At 6 month follow-up the shunt was open and the azygos vein aneurysm had resolved

  15. Open fenestration of the distal landing zone via a subxyphoid incision for subsequent endovascular repair of a dissecting thoracic aneurysm.

    Science.gov (United States)

    Konings, Renske; de Bruin, Jorg L; Wisselink, Willem

    2013-02-01

    To describe a novel hybrid technique to address two challenges in endovascular repair of chronic dissecting thoracic aortic aneurysm (dTAA): obtaining an adequate seal of the stent-graft in a half-moon-shaped fibrotic aortic lumen and preserving flow into the distal true and false lumens. The technique is demonstrated in a 52-year-old man who presented with progressive asymptomatic dilatation of the thoracic aorta 9 years after undergoing a Bentall procedure for a Stanford type A dissection followed by arch replacement and elephant trunk construction. Imaging at this admission showed a 6.8-cm dissecting aneurysm extending distally to ∼4 cm above the celiac trunk; the dissection included both common iliac arteries. The patient refused a thoracotomy, so a hybrid procedure was devised to resect the intimal flap via a median subxyphoid incision and transperitoneal approach through the lesser sac. Two overlapping Zenith TX-2 stent-grafts were deployed into the elephant trunk, terminating just above the surgically created "flow divider" at the level of the celiac trunk. Imaging showed adequate sealing at both ends of the stent-graft and a type II endoleak that persisted into follow-up, but the aneurysm diameter decreased to 6.4 cm, and there was unobstructed flow into the visceral, renal, and iliac arteries. In this case of chronic dTAA, open surgical removal of a segment of the dissection flap via a subxyphoid incision provided a distal landing zone for subsequent endoluminal repair, with exclusion of the aneurysm and preservation of antegrade flow in both true and false lumens.

  16. Innovations in vascular and endovascular surgery in Brazil: a data analysis study

    Directory of Open Access Journals (Sweden)

    Heriberto Brito de Oliveira

    2014-12-01

    Full Text Available Background:Innovations in vascular and endovascular surgery have important social and economic repercussions. Most endovascular devices used in Brazil are imported and, therefore, particularly expensive.Objective:To conduct a retrospective analysis of patent and regulatory approval data for newly developed vascular and endovascular devices, based on the number of patents registered at the Brazilian National Industrial Property Institute (INPI and the number of products approved by the National Health Surveillance Agency (ANVISA over recent years.Methods:This retrospective study involved electronic searches of the INPI (www.inpi.gov.br and ANVISA websites (www.anvisa.gov.br, for patents registered and products approved between January 1997 and December 2012.Results:The keywords used for the search ("catheter(s," "stent(s," "graft(s," and "wound dressing(s" returned a total of 701 new patents registered during the period studied. Thirty-four percent (n=237 of these were patents for wound dressings, while the remaining 66% (n=464 were for devices used in endovascular surgery. Only 7.8% (n=268 of the 3433 products approved by ANVISA during the period analyzed were produced in Brazil.Conclusions:The social and economic importance of innovations in health care highlights the need to monitor them, to register them and to support their production, in view of the need to develop local alternatives to imported health care technology.

  17. MRSA-Infected External Iliac Artery Pseudoaneurysm Treated with Endovascular Stenting

    International Nuclear Information System (INIS)

    Clarke, M.G.; Thomas, H.G.; Chester, J.F.

    2005-01-01

    A 48-year-old woman with severe juvenile-onset rheumatoid arthritis presented with a bleeding cutaneous sinus distal to her right total hip replacement scar. Methicillin resistant Staphylococcus aureus (MRSA) was isolated on culture. She had previously undergone bilateral total hip and knee replacements at aged 23 and six years later had the right knee prosthesis removed for infection, with subsequent osteomyelitis of the femoral shaft and right total hip prosthesis disruption. Peripheral arteriography was performed in view of persistent bleeding from the sinus, which revealed a 6 cm false aneurysm filling from and compressing the right external iliac artery (EIA). A PTFE-covered, balloon expandable JOSTENT was deployed in the right EIA, successfully excluding the false aneurysm and preventing further bleeding from the sinus. No graft infection was reported at 12 months. This case illustrates the potential use of endovascular stent-grafting in the treatment of an infected pseudoaneurysm

  18. Endovascular treatment of thoracic aortic pseudoaneurysm due to brucellosis: a rare case report.

    Science.gov (United States)

    Wang, Shuai; Wang, Qi; Liu, Han; Sun, Siqiao; Sun, Xiwei; Zhang, Yang; Wang, Zhongying; Cheng, Zhihua

    2017-06-02

    Arterial damage is a known complication of brucellosis, but the occurrence of a thoracic aortic pseudoaneurysm secondary to brucellosis has not been previously reported. A 65-year-old Chinese man presented with a pseudoaneurysm in the descending segment of the thoracic aorta that caused symptoms of chest pain and intermittent fever. He was diagnosed with a thoracic aortic pseudoaneurysm secondary to brucellosis based on a positive brucella serology test (standard-tube agglutination test) and imaging examination (computed tomography angiography). Anti-brucellosis treatment and covered stent graft implantation were attempted to eliminate the brucellosis and pseudoaneurysm, respectively, and were ultimately successful, with no symptoms after 6 months of follow-up. Endovascular repair may be effective and safe for treating a thoracic aortic pseudoaneurysm resulting from brucellosis.

  19. Intentional left subclavian artery coverage during thoracic endovascular aortic repair for traumatic aortic injury.

    Science.gov (United States)

    McBride, Cameron L; Dubose, Joseph J; Miller, Charles C; Perlick, Alexa P; Charlton-Ouw, Kristofer M; Estrera, Anthony L; Safi, Hazim J; Azizzadeh, Ali

    2015-01-01

    Thoracic endovascular aortic repair (TEVAR) is widely used for treatment of traumatic aortic injury (TAI). Stent graft coverage of the left subclavian artery (LSA) may be required in up to 40% of patients. We evaluated the long-term effects of intentional LSA coverage (LSAC) on symptoms and return to normal activity in TAI patients compared with a similarly treated group whose LSA was uncovered (LSAU). Patients were identified from a prospective institutional trauma registry between September 2005 and July 2012. TAI was confirmed using computed tomography angiography. The electronic medical records, angiograms, and computed tomography angiograms were reviewed in a retrospective fashion. In-person or telephone interviews were conducted using the SF-12v2 (Quality Metrics, Lincoln, RI) to assess quality of life. An additional questionnaire was used to assess specific LSA symptoms and the ability to return to normal activities. Data were analyzed by Spearman rank correlation and multiple linear and logistic regression analysis with appropriate transformations using SAS software (SAS Institute, Cary, NC). During the study period, 82 patients (57 men; mean age 40.5 ± 20 years, mean Injury Severity Score, 34 ± 10.0) underwent TEVAR for treatment of TAI. Among them, LSAC was used in 32 (39.5%) and LSAU in 50. A group of the LSAU patients (n = 22) served as matched controls in the analysis. We found no statistically significant difference in SF-12v2 physical health scores (ρ = -0.08; P = .62) between LSAC and LSAU patients. LSAC patients had slightly better mental health scores (ρ = 0.62; P = .037) than LSAU patients. LSAC patients did not have an increased likelihood of experiencing pain (ρ = -0.0056; P = .97), numbness (ρ = -0.12; P = .45), paresthesia (ρ = -0.11; P = .48), fatigue (ρ = -0.066; P = .69), or cramping (ρ = -0.12; P = .45). We found no difference between groups in the ability to return to activities. The mean follow-up time was 3.35 years. Six LSAC

  20. Endovascular treatment of the subclavian artery aneurysm in high-risk patient - a single-center experience

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2016-01-01

    Full Text Available We present our first experience with endovascular treatment of 6 subclavian artery aneurysms (SAA occurring in five male and one female patient. All patients, in our studies, according to ASA classification were high risk for open repair of SAA. The etiology of the all aneurysms was atherosclerosis degeneration of the artery. Two aneurysms were of intrathoracic location, then the other were extrathoracic. Symptoms related to subclavian artery aneurysms were present in two patients, compression and chest pain in one, and hemorrhage shock in second, while the remaining patients were asymptomatic. We preferred the Viabhan endoprosthesis for endovascular repair in 5 cases. In one patient with ruptured of subclavian artery aneurysm who was high-risk for open repair we made combined endovascular procedure. First at all, we covered the origin of left subclavian artery with thoracic stent graft and after that we put two coils in proximal part of subclavian artery. There was no operative mortality, and the early patency rate was 100%. The follow-up period was from 3 months to 3 years. During this period, one patient died of heart failure and one patient required endovascular reoperation due to endoleak type I. Endovascular treatment is recommended for all patients with subclavian artery aneurysm whenever this is possible due to anatomical reasons especially in high-risk patient with intrathoracic localization of aneurysm, to prevent potential complications.

  1. Endovascular Treatment of Anastomotic Pseudoaneurysms after Aorto-iliac Surgical Reconstruction

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Recaldini, Chiara; Lumia, Domenico; Cuffari, Salvatore; Caronno, Roberto; Castelli, Patrizio; Fugazzola, Carlo

    2007-01-01

    Purpose. To assess the effectiveness of endovascular treatment of anastomotic pseudoaneurysms (APAs) following aorto-iliac surgical reconstruction. Materials. We retrospectively evaluated 21 men who, between July 2000 and March 2006, were observed with 30 APAs, 13 to the proximal anastomosis and 17 to the distal anastomosis. The patients had had previous aorto-iliac reconstructive surgery with a bypass due to aneurysm (15/21) or obstructive disease (6/21). The following devices were used: 12 bifurcated endoprostheses, 2 aorto-monoiliac, 4 aortic extenders, 1 stent-graft leg, and 2 covered stents. Follow-up was performed with CT angiography at 1, 3, and 6 months after the procedure and yearly thereafter. Results. Immediate technical success was 100%. No periprocedural complications occurred. Four patients died during follow-up from causes not related to APA, and 1 (treated for prosthetic-enteric fistula) from sepsis 3 months after the procedure. During a mean follow-up of 19.7 months (range 1-72 months), 2 of 21 occlusions of stent-graft legs occurred 3 and 24 months after the procedure (treated with thrombolysis and percutaneous transluminal angioplasty and femorofemoral bypass, respectively) and 1 type I endoleak. Primary clinical success rate was 81% and secondary clinical success was 91%. Conclusion. Endovascular treatment is a valid alternative to open surgery and can be proposed as the treatment of choice for APAs, especially in patients who are a high surgical risk. Further studies with larger series and longer follow-up are necessary to confirm the long-term effectiveness of this approach

  2. Endovascular repair of mycotic aneurysm of the descending thoracic aorta: diagnostic and therapeutic dilemmas-two case reports with 1-year follow-up.

    Science.gov (United States)

    Marjanovic, Ivan; Sarac, Momir; Tomic, Aleksandar; Bezmarevic, Mihailo

    2013-10-01

    A mycotic aneurysm of the thoracic aorta is a rare diagnosis with high mortality. We present two cases of endovascular reconstruction of mycotic descending thoracic aorta. Specific or nonspecific bacterial or other infectious agent in serial samples of blood, urine, cerebrospinal fluid, and pleural puncture was not detected in the first case, but we found in sputum sample Mycobacterium tuberculosis in the second patient. We empirically began by administering broad-spectrum intravenous antibiotics in the first case, with preoperative antibiotic prophylaxis and antituberculotic drugs therapy in the second case, and continued with the same medication for 4 months after endovascular repair. Control computed tomographic scans 6 months after reconstruction showed no endoleak in both patients. Repair of mycotic descending thoracic aortic aneurysms by endoluminal stent graft is reasonable alternative to open surgical intervention. A broad-spectrum antibiotic therapy has a high significance in the treatment of patients with mycotic aneurysm. Georg Thieme Verlag KG Stuttgart · New York.

  3. Case report and review of the literature total endovascular repair of acute ascending aortic rupture: a case report and review of the literature.

    Science.gov (United States)

    McCallum, John C; Limmer, Karl K; Perricone, Anthony; Bandyk, Dennis; Kansal, Nikhil

    2013-07-01

    Thoracic aortic endografting has been successfully implemented to treat aneurysmal disease of the distal aortic arch and descending thoracic aorta. Although there are reports of ascending aortic endovascular interventions, the total endovascular repair of a ruptured ascending aorta secondary to a Type A dissection has not been described. We report the case of a 77-year-old patient who presented with a ruptured ascending aortic aneurysm secondary to degeneration of a Stanford type A aortic dissection. His surgical history was significant for orthotropic heart transplant 19 years prior. The dissection, aneurysm, and rupture occurred in the native aorta distal to the ascending aortic suture line. At presentation, he was hemodynamically unstable with a right hemothorax. We placed 3 Medtronic Talent Thoracic Stent Graft devices (Medtronic Inc, Minneapolis, MN) across the suture line in the ascending aorta, excluding the rupture. The patient survived and has been followed to 25 months.

  4. Endovascular treatment of thoracic aorta aneurysm and dissection

    International Nuclear Information System (INIS)

    Petrov, I.; Stankov, Z.; Stefanov, St.; Stoyanov, Hr.

    2015-01-01

    Full text: The aim is to give up to date information about modern endovascular treatment of aortic pathology Dissection and aneurysms of the aorta are life threatening condition requiring in most of the cases prompt surgical or endovascular treatment because of the poor natural evolution. Purpose: to assess the immediate and 1-year outcome of endovascular treatment in broad spectrum of acute and subacute aortic syndrome during the last 3 years (November 2012 - August 2015) in City Clinic (Sofia, Bulgaria). We performed endovascular treatment of 47 patients (43 men, 4 women) at average age 54 y. with dissection (24) and aneurysms (23) of the aortic arch and thoracic aorta (in 5 emergent treatment was performed for aortic rupture). All patients were treated with minimal surgical femoral approach. In 4 (9%) of them initial carotid to carotid bypass was performed in order to provide a sufficient landing zone for the endograft implantation.the last 9 patients (19%) were treated without general anesthesia with either deep sedation or epidural anesthesia. Results: In all patients successful endograft implantation was achieved. Additional stent-graft or open cell stent was implanted in 4 cases in order to centralize the flow in the compressed true lumen. In 5 cases additional vascular plug or large coil was delivered in the left subclavian arteryostium in order to interrupt retrograde aneurysm or false lumen filling. Complications: 30 days mortality-2.2%, neurologic disorders (4.4%). one year survival- 45 (90.5%). 3 and 6 mo control CT scan showed no migration of the graft in 100%, full false lumen isolation in 19 out of 24 dissections (80%) and aneurysm free of expansion in 20 out of 23 (86%), patent carotid bay-pass graft in 4 of 4 (100%). This one center study showed excellent immediate and 1 year clinical and device results from endovascular repair of potentially fatal disease. Endovascular treatment is a method of choice for broad spectrum of aortic pathology

  5. Endovascular aneurysm repair (EVAR) follow-up imaging: the assessment and treatment of common postoperative complications

    International Nuclear Information System (INIS)

    Ilyas, S.; Shaida, N.; Thakor, A.S.; Winterbottom, A.; Cousins, C.

    2015-01-01

    Endovascular abdominal aortic aneurysm repair (EVAR) is a well-established procedure, which has long-term mortality rates similar to that of open repair. It has the additional benefit of being less invasive, making it the favoured method of treating abdominal aortic aneurysms in elderly and high-risk patients with multiple co-morbidities. The main disadvantage of EVAR is the higher rate of re-intervention, due to device-related complications, including endoleaks, limb occlusion, stent migration, kinking, and infection. As a result lifelong surveillance is required. In order to avoid missing these complications, intricate knowledge of stent graft design, good-quality diagnostic ultrasound skills, multiplanar reformatting of CT images, and reproducible investigations are important. Most of these complications can be treated via an endovascular approach using cuff extensions, uncovered stents, coils, and liquid embolic agents. Open surgery is reserved for complex complications, where an endovascular approach is not feasible. - Highlights: • Comprehensive pictorial review of EVAR related complications. • Importance of life-long EVAR surveillance, to prevent aortic rupture or lower limb ischaemia. • Identification and management of endoleaks, rupture, migration, kink/infolding, occlusion and infection

  6. Endovascular repair of early rupture of Dacron aortic graft--two case reports.

    LENUS (Irish Health Repository)

    Sultan, Sherif

    2005-01-01

    Complications after open aortic surgery pose a challenge both to the vascular surgeon and the patient because of aging population, widespread use of cardiac revascularization, and improved survival after aortic surgery. The perioperative mortality rate for redo elective aortic surgery ranges from 5% to 29% and increases to 70-100% in emergency situation. Endovascular treatment of the postaortic open surgery (PAOS) patient has fewer complications and a lower mortality rate in comparison with redo open surgical repair. Two cases of ruptured abdominal aortic aneurysm (AAA) were managed with the conventional open surgical repair. Subsequently, spiral contrast computer tomography scans showed reperfusion of the AAA sac remnant mimicking a type III endoleak. These graft-related complications presented as vascular emergencies, and in both cases endovascular aneurysm repair (EVAR) procedure was performed successfully by aortouniiliac (AUI) stent graft and femorofemoral crossover bypass. These 2 patients add further merit to the cases reported in the English literature. This highlights the crucial importance of endovascular grafts in the management of such complex vascular problems.

  7. Management strategies for thoracic stent-graft repair of distal aortic arch lesions: is intentional subclavian artery occlusion a safe procedure?

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio; Salvatori, Filippo Maria; Pucci, Armando; Lucatelli, Pierleone; Rossi, Plinio; Passariello, Roberto [University of Rome La Sapienza, Department of Radiological Sciences, Rome (Italy); Dake, Michael D. [Stanford University School of Medicine, Department of Cardiothoracic Surgery Radiology, Stanford, CA (United States); Mazzesi, Giuseppe [University of Rome La Sapienza, Institute of Heart and Great Vessels, Rome (Italy)

    2009-10-15

    The aim of this retrospective analysis was to assess the clinical consequences after intentional left subclavian artery (LSA) occlusion. Thirty-seven patients, 27 type B dissection and 10 thoracic aneurysm, with short proximal neck (less than 2 cm) underwent endovascular treatment with intentional exclusion of LSA origin. No immediate complications occurred. Mean arterial pressure gradient, between right and left arms, ranged from 15 to 45 mmHg. After a mean follow-up of 43.70{+-}24.01 months, mild left arm symptoms secondary to flow reduction occurred in eight cases (21.6%) but only one required LSA transposition, after 8 months, for visual impairment. Type II endoleaks from excluded LSA occurred in 10 cases (27.0%): in seven patients, leaks were treated with coils and/or glue embolization; in one case, leak sealed spontaneously; one patient died before leak embolization could occur; one patient refused any further treatment. Intentional exclusion of the LSA may be justified when a longer proximal landing zone in the aortic arch is required. (orig.)

  8. Successful Endovascular Treatment of a Left Common Carotid Artery Aneurysm Following Failed Surgery of a Right Common Carotid Artery Aneurysm

    International Nuclear Information System (INIS)

    Cil, Barbaros E.; Ucar, Ibrahim; Ozsoy, Fatma; Arat, Anil; Yorgancioglu, Cem; Boeke, Erkmen

    2005-01-01

    Aneurysm of the common carotid artery is a rare and serious disease requiring prompt treatment in order to avoid neurologic complications. A 39-year-old man presented with voice impairment and a pulsatile mass at the right side of his neck and was found by color Doppler examination to have bilateral common carotid artery aneurysms of unknown origin. The right-sided large aneurysm was treated with placement of an 8 mm interposition Gore-Tex graft between the right common and internal carotid arteries. The surgical graft thrombosed 7 days after the surgery but the left-sided aneurysm was successfully treated by a Jostent peripheral stent-graft. Color Doppler examination showed a patent stent and no filling of the aneurysm on his first and sixth-month follow-up. Bilateral common carotid artery aneurysm is an exceptionally unusual condition and endovascular treatment of carotid artery aneurysms with covered stents may become an effective treatment alternative for these lesions

  9. Radiation Exposure in Endovascular Infra-Renal Aortic Aneurysm Repair and Factors that Influence It

    Directory of Open Access Journals (Sweden)

    Rui Machado

    Full Text Available Abstract Objective: The endovascular repair of aortic abdominal aneurysms exposes the patients and surgical team to ionizing radiation with risk of direct tissue damage and induction of gene mutation. This study aims to describe our standard of radiation exposure in endovascular aortic aneurysm repair and the factors that influence it. Methods: Retrospective analysis of a prospective database of patients with abdominal infra-renal aortic aneurysms submitted to endovascular repair. This study evaluated the radiation doses (dose area product (DAP, fluoroscopy durations and their relationships to the patients, aneurysms, and stent-graft characteristics. Results: This study included 127 patients with a mean age of 73 years. The mean DAP was 4.8 mGy.m2, and the fluoroscopy time was 21.8 minutes. Aortic bilateral iliac aneurysms, higher body mass index, aneurysms with diameters larger than 60 mm, necks with diameters larger than 28 mm, common iliac arteries with diameters larger than 20 mm, and neck angulations superior to 50 degrees were associated with an increased radiation dose. The number of anatomic risk factors present was associated with increased radiation exposure and fluoroscopy time, regardless of the anatomical risk factors. Conclusion: The radiation exposure during endovascular aortic aneurysm repair is significant (mean DAP 4.8 mGy.m2 with potential hazards to the surgical team and the patients. The anatomical characteristics of the aneurysm, patient characteristics, and the procedure's technical difficulty were all related to increased radiation exposure during endovascular aortic aneurysm repair procedures. Approximately 40% of radiation exposure can be explained by body mass index, neck angulation, aneurysm diameter, neck diameter, and aneurysm type.

  10. 3D printing of an aortic aneurysm to facilitate decision making and device selection for endovascular aneurysm repair in complex neck anatomy.

    Science.gov (United States)

    Tam, Matthew D B S; Laycock, Stephen D; Brown, James R I; Jakeways, Matthew

    2013-12-01

    To describe rapid prototyping or 3-dimensional (3D) printing of aneurysms with complex neck anatomy to facilitate endovascular aneurysm repair (EVAR). A 75-year-old man had a 6.6-cm infrarenal aortic aneurysm that appeared on computed tomographic angiography to have a sharp neck angulation of ~90°. However, although the computed tomography (CT) data were analyzed using centerline of flow, the true neck length and relations of the ostial origins were difficult to determine. No multidisciplinary consensus could be reached as to which stent-graft to use owing to these borderline features of the neck anatomy. Based on past experience with rapid prototyping technology, a decision was taken to print a model of the aneurysm to aid in visualization of the neck anatomy. The CT data were segmented, processed, and converted into a stereolithographic format representing the lumen as a 3D volume, from which a full-sized replica was printed within 24 hours. The model demonstrated that the neck was adequate for stent-graft repair using the Aorfix device. Rapid prototyping of aortic aneurysms is feasible and can aid decision making and device delivery. Further work is required to test the value of 3D replicas in planning procedures and their impact on procedure time, radiation dose, and procedure cost.

  11. Italian Percutaneous EVAR (IPER) Registry: outcomes of 2381 percutaneous femoral access sites' closure for aortic stent-graft.

    Science.gov (United States)

    Pratesi, G; Barbante, M; Pulli, R; Fargion, A; Dorigo, W; Bisceglie, R; Ippoliti, A; Pratesi, C

    2015-12-01

    The aim of this paper was to report outcomes of endovascular aneurysm repair with percutaneous femoral access (pEVAR) using Prostar XL and Proglide closure systems (Abbot Vascular, Santa Clara, CA, USA), from the multicenter Italian Percutaneous EVAR (IPER) registry. Consecutive patients affected by aortic pathology treated by EVAR with percutaneous access (pEVAR) between January 2010 and December 2014 at seven Italian centers were enrolled in this multicenter registry. All the operators had an experience of at least 50 percutaneous femoral access procedures. Data were prospectively collected into a dedicated online database including patient's demographics, anatomical features, intra- and postoperative outcomes. A retrospective analysis was carried out to report intraoperative and 30-day technical success and access-related complication rate. Uni- and multivariate analyses were performed to identify factors potentially associated with an increased risk of percutaneous pEVAR failure. A total of 2381 accesses were collected in 1322 patients, 1249 (94.4%) male with a mean age of 73.5±8.3 years (range 45-97). The overall technical success rate was 96.8% (2305/2381). Major intraoperative access-related complications requiring conversion to surgical cut-down were observed in 3.2% of the cases (76/2381). One-month pEVAR failure-rate was 0.25% (6/2381). Presence of femoral artery calcifications resulted to be a significant predictor of technical failure (OR: 1.69; 95% CI: 1.03-2.77; P=0.036) at multivariate analysis. No significant association was observed with sex (P=0.28), obesity (P=0.64), CFA diameter (P=0.32), level of CFA bifurcation (P=0.94) and sheath size >18 F (P=0.24). The use of Proglide was associated with a lower failure rate compared to Prostar XL (2.5% vs. 3.3%) despite not statistically significant (P=0.33). The results of the IPER registry confirm the high technical success rate of percutaneous EVAR when performed by experienced operators, even in

  12. Endovascular Repair of Traumatic Rupture of the Thoracic Aorta: Single-Center Experience

    International Nuclear Information System (INIS)

    Saratzis, Nikolaos A.; Saratzis, Athanasios N.; Melas, Nikolaos; Ginis, Georgios; Lioupis, Athanasios; Lykopoulos, Dimitrios; Lazaridis, John; Dimitrios, Kiskinis

    2007-01-01

    Purpose. Traumatic rupture of the thoracic aorta secondary to blunt chest trauma is a life-threatening emergency and a common cause of death, usually following violent collisions. The objective of this retrospective report was to evaluate the efficacy of endovascular treatment of thoracic aortic disruptions with a single commercially available stent-graft. Methods. Nine men (mean age 29.5 years) were admitted to our institution between January 2003 and January 2006 due to blunt aortic trauma following violent motor vehicle collisions. Plain chest radiography, spiral computed tomography, aortography, and transesophageal echocardiography were used for diagnostic purposes in all cases. All patients were diagnosed with contained extramural thoracic aortic hematomas, secondary to aortic disruption. One patient was also diagnosed with a traumatic thoracic aortic dissection, secondary to blunt trauma. All subjects were poor surgical candidates, due to major injuries such as multiple bone fractures, abdominal hematomas, and pulmonary contusions. All repairs were performed using the EndoFit (LeMaitre Vascular) stent-graft. Results. Complete exclusion of the traumatic aortic disruption and pseudoaneurysm was achieved and verified at intraoperative arteriography and on CT scans, within 10 days of the repair in all patients. In 1 case the deployment of a second cuff was necessary due to a secondary endoleak. In 2 cases the left subclavian artery was occluded to achieve adequate graft fixation. No procedure-related deaths have occurred and no cardiac or peripheral vascular complications were observed within the 12 months (range 8-16 months) follow-up. Conclusions. This is the first time the EndoFit graft has been utilized in the treatment of thoracic aortic disruptions secondary to chest trauma. The repair of such pathologies is technically feasible and early follow-up results are promising

  13. Concepts to optimize stent-grafting of abdominal aortic aneurysms based on results of experimental studies; Konzepte zur Optimierung der Stentgraftversorgung von Bauchaortenaneurysmen auf der Basis tierexperimenteller Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Chavan, A.; Kirchhoff, T.; Baus, S.; Galanski, M. [Medizinische Hochschule Hannover (Germany). Abt. Diagnostische Radiologie 1; Pichlmaier, M. [Medizinische Hochschule Hannover (Germany). Leibniz Forschungslab. fuer Biotechnologie und Kuenstliche Organe an der Klinik fuer Thorax-, Herz- und Gefaesschirurgie

    2001-08-01

    Purpose. In the endoluminal therapy of abdominal aortic aneurysms, a short proximal aneurysm neck, endoleaks and the large size and stiffness of the introducer systems are responsible for many of the complications and sub-optimal outcomes. The purpose of the present review article is to to suggest strategies to minimize these complications based on the results of experimental studies in animals. Material and methods. After implanting various types of stents across the renal artery origins, the functional and morphological changes in the kidneys and renal vessels were studied by various authors. In order to prevent progressive widening of the proximal aneurysmal neck and graft dislocation, Sonesson et al. performed a laparoscopic banding around the proximal neck in pigs. To study the effects of endoleaks, Marty, Schurink and Pitton carried out pressure measurements in experimental aneurysms with and without endoleaks. Sakaguchi and Pavcnik developed the 'Twin-tube endografts' (TTEG) and the 'Bifurcated drum occluder endografts' (BDOEG) and tested them in dogs. Results. Up to 3 months after suprarenal stent placement, Chavan et al. detected no significant fall in the mean inulin clearance in sheep (140{+-}46 ml/min before, 137{+-}58 ml/min after). Nasim et al. and Malina et al. reported similar observations with respect to renal function. Suprarenal fixation may result in isolated thrombotic occlusions of the renal arteries and microinfarcts in the kidneys. Mean aortic diameters at the level of banding were significantly smaller in the animals with aortic banding as opposed to those in the control group without banding (8 mm vs 11 mm, p=0.004). The banding caused a secure proximal fixation of the stent-graft. Persistent endoleaks resulted in significantly higher intraaneurysmal pressures. Although the TTEG and the BDOEG stent-grafts required smaller sheaths, occlusions were observed in 8% (TTEG) and 60% (BDOEG) of the graft limbs. (orig.) [German

  14. Endovascular Repair of an Actively Hemorrhaging Stab Wound Injury to the Abdominal Aorta

    International Nuclear Information System (INIS)

    Hussain, Qasim; Maleux, Geert; Heye, Sam; Fourneau, Inge

    2008-01-01

    Traumatic injury of the abdominal aorta is rare and potentially lethal (Yeh et al., J Vasc Surg 42(5):1007-1009, 2005; Chicos et al., Chirurgia (Bucur) 102(2):237-240, 2007) as it can result in major retroperitoneal hemorrhage, requiring an urgent open surgery. In case of concomitant bowel injury or other conditions of hostile abdomen, endovascular repair can be an alternative treatment. This case report deals with a 50-year-old man presenting at the emergency ward with three stab wounds: two in the abdomen and one in the chest. During explorative laparotomy, liver laceration and bowel perforation were repaired. One day later, abdominal CT-scan revealed an additional retroperitoneal hematoma associated with an aortic pseudoaneurysm, located anteriorly 3 cm above the aortic bifurcation. Because of the risk of graft infection, an endovascular repair of the aortic injury using a Gore excluder stent-graft was performed. Radiological and clinical follow-up revealed a gradual shrinkage of the pseudo-aneurysm and no sign of graft infection at two years' follow-up.

  15. Endovascular repair of abdominal aortic aneurysms: vascular anatomy, device selection, procedure, and procedure-specific complications.

    Science.gov (United States)

    Bryce, Yolanda; Rogoff, Philip; Romanelli, Donald; Reichle, Ralph

    2015-01-01

    Abdominal aortic aneurysm (AAA) is abnormal dilatation of the aorta, carrying a substantial risk of rupture and thereby marked risk of death. Open repair of AAA involves lengthy surgery time, anesthesia, and substantial recovery time. Endovascular aneurysm repair (EVAR) provides a safer option for patients with advanced age and pulmonary, cardiac, and renal dysfunction. Successful endovascular repair of AAA depends on correct selection of patients (on the basis of their vascular anatomy), choice of the correct endoprosthesis, and familiarity with the technique and procedure-specific complications. The type of aneurysm is defined by its location with respect to the renal arteries, whether it is a true or false aneurysm, and whether the common iliac arteries are involved. Vascular anatomy can be divided more technically into aortic neck, aortic aneurysm, pelvic perfusion, and iliac morphology, with grades of difficulty with respect to EVAR, aortic neck morphology being the most common factor to affect EVAR appropriateness. When choosing among the devices available on the market, one must consider the patient's vascular anatomy and choose between devices that provide suprarenal fixation versus those that provide infrarenal fixation. A successful technique can be divided into preprocedural imaging, ancillary procedures before AAA stent-graft placement, the procedure itself, postprocedural medical therapy, and postprocedural imaging surveillance. Imaging surveillance is important in assessing complications such as limb thrombosis, endoleaks, graft migration, enlargement of the aneurysm sac, and rupture. Last, one must consider the issue of radiation safety with regard to EVAR. (©)RSNA, 2015.

  16. The effect of transluminal stent-graft placement on blood flow of abdominal branch vessels in type B aortic dissection

    International Nuclear Information System (INIS)

    Huang Lianjun; Yang Jian; Yu Feicheng; Sun Lizhong; Zhu Junming; Zhang Yan; Jiang Shiliang

    2005-01-01

    Objective: To evaluate the effect of TSGP on blood flow of abdominal branch vessels of Type B dissection. Methods: Thirty-five patients with type B aortic dissection underwent TSGP. The blood flow of abdominal branch vessels was analyzed via EBCT, MRI, and DSA before and after procedure. Results: A total of 140 important vessels from abdominal aorta in 35 patients, including celiac artery, SMA, right and left renal arteries were analyzed via EBCT, MRI, and DSA. 58 branches were affected by dissection, of which 14 (10% ) were dynamic impairment; and 44 (31.4%) were static impairment. After TSGP, the blood flow of impaired branches all showed improvement at different degrees, no post-operative ischemic complications occurred. Conclusion: TSGP could improve the blood flow immediately not only the dynamic but also the static ischemia of abdominal aorta branch vessels caused by type B aortic dissection. Further study is still need to observe the mid-term and long-term effect of TSGP. (authors)

  17. Technical and clinical outcome of transjugular intrahepatic portosystemic stent shunt: Bare metal stents (BMS) versus viatorr stent-grafts (VSG)

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Christof M., E-mail: cmsommer@gmx.com [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Gockner, Theresa L.; Stampfl, Ulrike; Bellemann, Nadine [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Sauer, Peter; Ganten, Tom [Department of Gastroenterology, University Hospital Heidelberg, Heidelberg (Germany); Weitz, Juergen [Department of General, Abdominal and Transplantation Surgery, University Hospital Heidelberg, Heidelberg (Germany); Kauczor, Hans U.; Radeleff, Boris A. [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany)

    2012-09-15

    Highlights: ► Twelve month mean number of TIPS revisions per patient was significantly lower in VSG. ► First TIPS revision was performed significantly later in the VSG. ► There was no significant difference of hepatic encephalopathy in both study groups. -- Abstract: Purpose: To compare retrospectively angiographical and clinical results in patients undergoing transjugular intrahepatic portosystemic stent-shunt (TIPS) using BMS or VSG. Materials and methods: From February 2001 to January 2010, 245 patients underwent TIPS. From those, 174 patients matched the inclusion criteria with elective procedures and institutional follow-up. Group (I) consisted of 116 patients (mean age, 57.0 ± 11.1 years) with BMS. Group (II) consisted of 58 patients with VSG (mean age, 53.5 ± 16.1 years). Angiographic and clinical controls were scheduled at 3, 6 and 12 months, followed by clinical controls every 6 months. Primary study goals included hemodynamic success, shunt patency as well as time to and number of revisions. Secondary study goals included clinical success. Results: Hemodynamic success was 92.2% in I and 91.4% in II (n.s.). Primary patency was significantly higher in II compared to I (53.8% after 440.4 ± 474.5 days versus 45.8% after 340.1 ± 413.8 days; p < 0.05). The first TIPS revision was performed significantly later in II compared to I (288.3 ± 334.7 days versus 180.1 ± 307.0 days; p < 0.05). In the first angiographic control, a portosystemic pressure gradient ≥15 mmHg was present in 73.9% in I and in 39.4% in II (p < 0.05). Clinical success was 73.7–86.2% after 466.3 ± 670.1 days in I and 85.7–90.5% after 617.5 ± 642.7 days in II (n.s.). Hepatic encephalopathy was 37.5% in I and 36.5% in II (n.s.). Conclusion: VSG increased primary shunt patency as well as decreased time to and number of TIPS revisions. There was a trend of higher clinical success in VSG without increased hepatic encephalopathy.

  18. Technical and clinical outcome of transjugular intrahepatic portosystemic stent shunt: Bare metal stents (BMS) versus viatorr stent-grafts (VSG)

    International Nuclear Information System (INIS)

    Sommer, Christof M.; Gockner, Theresa L.; Stampfl, Ulrike; Bellemann, Nadine; Sauer, Peter; Ganten, Tom; Weitz, Juergen; Kauczor, Hans U.; Radeleff, Boris A.

    2012-01-01

    Highlights: ► Twelve month mean number of TIPS revisions per patient was significantly lower in VSG. ► First TIPS revision was performed significantly later in the VSG. ► There was no significant difference of hepatic encephalopathy in both study groups. -- Abstract: Purpose: To compare retrospectively angiographical and clinical results in patients undergoing transjugular intrahepatic portosystemic stent-shunt (TIPS) using BMS or VSG. Materials and methods: From February 2001 to January 2010, 245 patients underwent TIPS. From those, 174 patients matched the inclusion criteria with elective procedures and institutional follow-up. Group (I) consisted of 116 patients (mean age, 57.0 ± 11.1 years) with BMS. Group (II) consisted of 58 patients with VSG (mean age, 53.5 ± 16.1 years). Angiographic and clinical controls were scheduled at 3, 6 and 12 months, followed by clinical controls every 6 months. Primary study goals included hemodynamic success, shunt patency as well as time to and number of revisions. Secondary study goals included clinical success. Results: Hemodynamic success was 92.2% in I and 91.4% in II (n.s.). Primary patency was significantly higher in II compared to I (53.8% after 440.4 ± 474.5 days versus 45.8% after 340.1 ± 413.8 days; p < 0.05). The first TIPS revision was performed significantly later in II compared to I (288.3 ± 334.7 days versus 180.1 ± 307.0 days; p < 0.05). In the first angiographic control, a portosystemic pressure gradient ≥15 mmHg was present in 73.9% in I and in 39.4% in II (p < 0.05). Clinical success was 73.7–86.2% after 466.3 ± 670.1 days in I and 85.7–90.5% after 617.5 ± 642.7 days in II (n.s.). Hepatic encephalopathy was 37.5% in I and 36.5% in II (n.s.). Conclusion: VSG increased primary shunt patency as well as decreased time to and number of TIPS revisions. There was a trend of higher clinical success in VSG without increased hepatic encephalopathy

  19. Efficacy and Safety of Augmenting the Preclose Technique with a Collagen-Based Closure Device for Percutaneous Endovascular Aneurysm Repair

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rafiuddin, E-mail: rafiuddin.patel@ouh.nhs.uk [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom); Juszczak, Maciej T. [Oxford University Hospitals NHS Trust, Department of Vascular Surgery, John Radcliffe Hospital (United Kingdom); Bratby, Mark J. [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom); Sideso, Ediri [Oxford University Hospitals NHS Trust, Department of Vascular Surgery, John Radcliffe Hospital (United Kingdom); Anthony, Susan; Tapping, Charles R. [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom); Handa, Ashok; Darby, Christopher R.; Perkins, Jeremy [Oxford University Hospitals NHS Trust, Department of Vascular Surgery, John Radcliffe Hospital (United Kingdom); Uberoi, Raman [Oxford University Hospitals NHS Trust, Department of Radiology, John Radcliffe Hospital (United Kingdom)

    2015-08-15

    PurposeTo report our experience of selectively augmenting the preclose technique for percutaneous endovascular aneurysm repair (p-EVAR) with an Angio-Seal device as a haemostatic adjunct in cases of significant bleeding after tensioning the sutures of the suture-mediated closure devices.Materials and MethodsProspectively collected data for p-EVAR patients at our institute were analysed. Outcomes included technical success and access site complications. A logistic regression model was used to analyse the effects of sheath size, CFA features and stent graft type on primary failure of the preclose technique necessitating augmentation and also on the development of complications.Resultsp-EVAR was attempted via 122 CFA access sites with a median sheath size of 18-French (range 12- to 28-French). Primary success of the preclose technique was 75.4 % (92/122). Angio-Seal augmentation was utilised as an adjunct to the preclose technique in 20.5 % (25/122). The overall p-EVAR success rate was 95.1 % (116/122). There was a statistically significant relationship (p = 0.0093) between depth of CFA and primary failure of preclose technique. CFA diameter, calcification, type of stent graft and sheath size did not have significant effects on primary preclose technique failure. Overall 4.9 % (6/122) required surgical conversion but otherwise there were no major complications.ConclusionAugmentation with an Angio-Seal device is a safe and effective adjunct to increase the success rate of the preclose technique in p-EVAR.

  20. Mortality within the endovascular treatment in Stanford type B aortic dissections Mortalidade no tratamento endovascular nas dissecções aórticas tipo B

    Directory of Open Access Journals (Sweden)

    Alexandre Fioranelli

    2011-06-01

    Full Text Available BACKGROUND: Endovascular stent-graft repair of aortic dissections is a relatively new procedure, and although apparently less invasive, the efficacy and safety of this technique have not been fully established. OBJECTIVE: To evaluate mortality in patients with complicated Stanford type B aortic dissections submitted to endovascular treatment. METHODS: Clinical, anatomical, imaging and autopsy data of 23 patients with complicated type B aortic dissections were reviewed from November 2004 to October 2007. The main indications for transluminal thoracic stent-grafting included: persistent pain in spite of medical therapy, signs of distal limb ischemia, signs of aortic rupture, progression of aneurismal dilation of the descending aorta during follow-up (defined as a diameter > 50 mm and the diameter of descending thoracic aorta of 40mm or larger at the onset of aortic dissection. Data were analyzed statistically; all p-values were two-tailed and differences INTRODUÇÃO: O tratamento endovascular na dissecção de aorta é um procedimento relativamente novo e, embora aparentemente menos invasivo, a eficácia e a segurança dessa técnica não estão totalmente estabelecidas. OBJETIVO: Avaliar a mortalidade e complicações nos pacientes submetidos a tratamento endovascular na dissecção de aorta tipo B de Stanford. MÉTODOS: Foram revisados, a partir de novembro de 2004 a outubro de 2007, em estudo clínico, anatômico, de imagens e dados da autopsia de 23 pacientes com dissecção aórtica tipo B. As principais indicações para o procedimento foram: dor persistente apesar da terapia médica, sinais de isquemia distal do membro, sinais de ruptura da aorta, progressão da dilatação do aneurisma da aorta descendente, durante o seguimento (definida como um diâmetro > 5 cm e descendente da aorta torácica de 40 mm ou mais de diâmetro no início da dissecção aórtica. Os dados foram analisados estatisticamente considerados erro alfa de 5%. As vari

  1. Alternativa técnica no tratamento endovascular dos aneurismas da artéria poplítea A technical alternative for the endovascular treatment of popliteal artery aneurysms

    Directory of Open Access Journals (Sweden)

    Marcelo Ferreira

    2008-03-01

    Full Text Available O aneurisma de artéria poplítea é relativamente raro, porém representa cerca de 85% de todos os aneurismas arteriais periféricos. Apresenta-se geralmente com um quadro de complicação isquêmica e elevado risco de perda do membro acometido. Em função disso, preconiza-se seu tratamento eletivo, atualmente realizado com resultados satisfatórios pela técnica endovascular. Relatamos nossa experiência com a utilização do stent de nitinol auto-expansível revestido com PTFEe - Fluency (Bard, Alemanha, reforçado internamente com o stent de nitinol auto-expansível Zilver (Cook, EUA no tratamento de um aneurisma de artéria poplítea.Popliteal artery aneurysm is relatively rare, but represents around 85% of all peripheral arterial aneurysms. It is usually presented with ischemic complication and high risk of limb loss. For that reason, its elective treatment is indicated and currently carried through with satisfactory results using endovascular techniques. We describe our experience with the use of an ePTFE-covered nitinol self-expandable stent graft - Fluency (Bard, Germany, reinforced internally with the nitinol self-expandable Zilver stent (Cook, USA for the treatment of a popliteal artery aneurism.

  2. Estudo da resposta tissular à endoprótese recoberta de jugular bovina em veia cava inferior de suínos Bovine jugular covered stent-graft implanted in swine inferior vena cava - a study of tissue response

    Directory of Open Access Journals (Sweden)

    Cristina Ribeiro Riguetti Pinto

    2006-06-01

    aortic stent-graft deployment (Florida, USA. Ten handmade stent-grafts were implanted in 10 swine inferior venae cavae. All animals were submitted to perioperative venography. At necropsy, 2 months later, the stent-grafts were removed en bloc and histopathologic analysis was undertaken, in order to analyze its patency, adherence to neighboring tissues and incorporation to the venous wall, as well as tissue response. RESULTS: All stent-grafts were patent and adherent to venous wall, but six presented with gross trabeculation and four had some degree of perivascular fibrosis at macroscopy. Three animals developed lymphocele, one in the retroperitoneal space and the others in the abdominal wall. At histopathology, we observed chronic inflammatory reaction with foreign body granulomatous response in all cases, with prevalence of the tunica media (80%. CONCLUSION: The model presented low thrombogenicity, which corroborates the efficacy of the chosen means of preservation and material. However, there was low compatibility, probably due to the immunological obstacle of xenografts and exaggerated tissue response of the venous territory.

  3. Endovascular repair of an aorto-iliac aneurysm succeeded by kidney transplantation Tratamento endovascular de aneurisma aorto-ilíaco sucedido por transplante renal

    Directory of Open Access Journals (Sweden)

    Marcelo Bellini Dalio

    2010-09-01

    Full Text Available We present the case of aorto-iliac aneurysm in a patient with chronic renal failure requiring dialysis who were treated with an endovascular stent graft and, later on, submitted to kidney transplantation. A 53-year-old male with renal failure requiring dialysis presented with an asymptomatic abdominal aorto-iliac aneurysm measuring 5.0cm of diameter. He was treated with endovascular repair technique, being used an endoprosthesis Excluder®. After four months, he was successfully submitted to kidney transplantation (dead donor, with anastomosis of the graft renal artery in the external iliac artery distal to the endoprosthesis. The magnetic resonance imaging, carried out 30 days after the procedure, showed a good positioning of the endoprosthesis and adequate perfusion of the renal graft. In the follow-up, the patient presented improvement of nitrogenous waste, good positioning of the endoprosthesis without migration or endoleak. The endovascular repair of aorto-iliac aneurysm in a patient with end-stage renal failure under hemodialysis treatment showed to be feasible, safe and efficient, as it did not prevent the success of the posterior kidney transplantation.Apresentamos o caso de aneurisma aortoilíaco em um paciente com insuficiência renal crônica dialítica tratado com uma endoprótese vascular, sendo, após, submetido a transplante renal. Um homem de 53 anos com insuficiência renal dialítica apresentava um aneurisma abdominal aortoilíaco assintomático com 5,0cm de diâmetro. Foi tratado com técnica endovascular com uma endoprótese Excluderâ. Após quatro meses, foi submetido a transplante renal (doador cadáver com sucesso, com anastomose da artéria renal do enxerto na artéria ilíaca externa distal à endoprótese. A ressonância magnética 30 dias após o procedimento mostrou a endoprótese bem posicionada e o enxerto renal bem perfundido. No seguimento, o paciente evoluiu com melhora das escórias nitrogenadas, bom

  4. Endovascular repair of blunt popliteal arterial injuries

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Shan; Zhang, Xiquan; Chen, Zhong; Zhu, Wei; Pan, Xiaolin [Dept. of nterventional Vascular, The 148th Hospital of Chinese People' s Liberation Army, Zibo (China); Dong, Peng; Sun, Yequan [Dept. of Medical Imaging, Weifang Medical University, Weifang (China); Qi, Deming [Dept. of Medical Imaging, Qilu Medical University, Zibo (China)

    2016-09-15

    To evaluate the feasibility and effectiveness of endovascular repair for blunt popliteal arterial injuries. A retrospective analysis of seven patients with clinical suspicion of popliteal arterial injuries that were confirmed by arteriography was performed from September 2009 to July 2014. Clinical data included demographics, mechanism of injury, type of injury, location of injury, concomitant injuries, time of endovascular procedures, time interval from trauma to blood flow restoration, instrument utilized, and follow-up. All patients were male (mean age of 35.9 ± 10.3 years). The type of lesion involved intimal injury (n = 1), partial transection (n = 2), complete transection (n = 2), arteriovenous fistula (n = 1), and pseudoaneurysm (n = 1). All patients underwent endovascular repair of blunt popliteal arterial injuries. Technical success rate was 100%. Intimal injury was treated with a bare-metal stent. Pseudoaneurysm and popliteal artery transections were treated with bare-metal stents. Arteriovenous fistula was treated with bare-metal stent and coils. No perioperative death and procedure-related complication occurred. The average follow-up was 20.9 ± 2.3 months (range 18–24 months). One patient underwent intra-arterial thrombolysis due to stent thrombosis at 18 months after the procedure. All limbs were salvaged. Stent migration, deformation, or fracture was not found during the follow-up. Endovascular repair seems to be a viable approach for patients with blunt popliteal arterial injuries, especially on an emergency basis. Endovascular repair may be effective in the short-term. Further studies are required to evaluate the long-term efficacy of endovascular repair.

  5. Endovascular Aneurysm Repair of Acute Occlusion of Abdominal Aortic Aneurysm with Intra-Aneurysmal Dissection.

    Science.gov (United States)

    Terai, Yasuhiko; Mitsuoka, Hiroshi; Nakai, Masanao; Goto, Shinnosuke; Miyano, Yuta; Tsuchiya, Hirokazu; Yamazaki, Fumio

    2015-11-01

    To report a rare case of acute abdominal aortic aneurysm (AAA) occlusion successfully treated by endovascular aneurysm repair (EVAR). An 89-year-old man complained of severe back pain and weakness in the bilateral lower extremities. Although there were neither acute ischemic signs on the brain computed tomography (CT) nor critical leg ischemia, the patient presented progressing weakness in the bilateral lower extremities and decreased sensation in the perianal and saddle area. Contrast-enhanced CT demonstrated an infrarenal AAA, the formation of an ulcer-like lesion in the aneurysmal wall, and the complete occlusion of distal AAA because of the caudal extension of intramural hematoma. Both common iliac arteries were patent because of the development of collateral vessels. The neurologic symptoms were considered to be caused by the occlusion of lumbar radicular arteries. EVAR seemed anatomically feasible, if the occlusion could be crossed by guidewires from both side of the common femoral artery. Wires easily traversed the occlusion, and the stent graft could be smoothly unwrapped and opened. The patient could recover decent iliac arterial flow. The neurovascular deficits recovered within 4 days after the procedure. Although our experience may not be reproduced in all case of AAA occlusion, EVAR warrants consideration to reduce the high mortality rate associated with the classical treatments. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. [Outcomes of endovascular repairing aortic arch disease hybrid with supra-arch debranching procedures].

    Science.gov (United States)

    Wang, Mian; Chang, Guangqi; Yin, Henghui; Yao, Chen; Wang, Jinsong; Wang, Shenming

    2015-11-01

    To summarize the experience of endovascular repairing aortic arch disease hybrid with supra-arch debranching procedures. It was a retrospective study. From January 2002 to December 2014, 42 high risk patients with aortic arch disease were treated by supra-arch debranching hybrid with subsequent endovascular repair in the First Affiliated Hospital of Sun Yat-sen University. There were 39 male and 3 female patients with a mean age of (53±13) years (ranging from 34 to 80 years). Of the 42 patients, 7 were thoracic aortic aneurysm, 20 were Stanford type B aortic dissection and 15 were Stanford type A aortic dissection. After the supra-aortic debranching technique, simultaneous (n=16) or staged (n=26, mean interval (7±3) days) endovascular repair were performed. Fisher exact test was used to compare the in-hospital mortality of ascending aorta based debranching and non-ascending aorta based debranching. Technical success rate was 81.0% (34/42). The overall 30-day complication rate was 31.0% (13/42), including 3 cerebral stroke (7.1%), 8 endoleak (19.0%, including 6 type I endoleak and 2 type II endoleak), 1 circulatory failure, 1 aorto-tracheal fistula. The 30-day mortality was 9.5% (4/42), 2 died of cerebral stroke, 1 died of circulatory failure, 1 died of aorto-tracheal fistula. The in-hospital mortality of ascending aorta based debranching group was obviously higher than that of the non-ascending aorta based debranching group (4/16 vs. 0, P=0.02). The median time of follow-up was 64.8 (2 to 156.9) months. CT scanning was performed at 1, 3 months after surgery and annually thereafter. The overall survival rate was 76.6%. During the follow-up period, there was 4 deaths, and 2 of them were aortic artery related (5.3%). There were 4 de novo complications during the follow-up period, 1 stroke attributed to bypass occlusion was cured by medical treatment, 2 pseudoaneurysm was successfully treated with open surgery, 1 stent-graft induced new distal entry tear was

  7. Endovascular management of pancreatitis-related pseudoaneurysms: A review of techniques.

    Directory of Open Access Journals (Sweden)

    Bartosz Zabicki

    Full Text Available To present the various techniques used in the management of pancreatitis-related pseudoaneurysms of visceral vessels.The retrospective clinical study was carried out at the Department of Diagnostic and Interventional Radiology at Poznan University of Medical Sciences from 2011 to 2016. The fifteen patients included in the study were diagnosed with pseudoaneurysms of visceral arteries, as a complication of chronic pancreatitis. The diagnosis was made using contrast-enhanced computed tomography, followed by angiography. On admission, all patients were symptomatic, with varying degrees of abdominal pain. One patient was haemodynamically unstable. Treatments with endovascular techniques were analysed, along with their efficacy and outcomes. Coil embolisation was performed in 5 patients. Stent graft was used in 1 patient. Liquid embolic agents were used in 7 cases, of which 5 patients were treated with thrombin injection and 2 with Squid. A combination of techniques was used in 2 patients.The most common artery affected by pseudoaneurysm formation was the splenic artery (7/15; 46.7%, and the size of the pseudoaneurysms ranged from 27 mm to 85 mm. Primary technical success was achieved in 14 out of 15 patients (93.3%. One patient required reintervention. Two patients required splenectomy after embolisation due to splenic ischemia. No recanalisation was present at the follow-up computed tomography performed after 1 to 3 weeks, and no mortality was observed within 30 days.Vascular complications of pancreatitis require accurate diagnosis and immediate treatment. Endovascular intervention is highly effective and is the preferred treatment option. The technique used is determined based on vascular anatomy and the patient's haemodynamic status.

  8. Endovascular repair of an iliac arteriovenous fistula secondary to perforation from a common iliac aneurysm in a patient with Ehler-Danlos syndrome.

    Science.gov (United States)

    Sala Almonacil, Vicente Andrés; Zaragozá García, José Miguel; Gómez Palonés, Francisco Julián; Plaza Martínez, Ángel; Ortíz Monzón, Eduardo

    2012-08-01

    Type IV Ehler-Danlos syndrome (EDS) patients are prone to life-threatening vascular complications. Surgical management of those complications is challenging owing to vessel wall fragility, which may result in hemorrhagic events and high mortality rates. Here we report a case of left common iliac aneurysm perforation of the ipsilateral iliac vein repaired using endovascular technique in a patient with EDS. A 54-year-old patient presented with heart failure symptoms that evolved over 1 week in association with left leg edema and steal syndrome due to a perforation of the left iliac vein caused by a left common iliac aneurysm. A thrombosed right common iliac aneurysm and several other visceral and peripheral aneurysms were discovered on computed tomographic scan at admission. An aortouniiliac stent graft was used to seal the fistula. After 18 months of follow-up, the patient remained asymptomatic. We suggest that endovascular therapy is useful to manage vascular complications in patients with EDS. Copyright © 2012 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  9. Endovascular treatment of intracranial arteriovenous malformations

    International Nuclear Information System (INIS)

    Seruga, T.

    2002-01-01

    Background. The aim of the study was the introduction of endovascular interventional treatment of cerebral arteriovenous malformations (AVM) with superselective embolization with cyanoacrylic polymerisation agent. Case reports. Endovascular embolization was performed in five patients with cerebral AVMs. Three of these patients were presented with intracerebral haemathomas whereas in other two patients, cerebral AVM was an incidental finding. Superselective catheterisation of AVMs was performed and acrylic glue was selectively injected into the nidus. Conclusions. Control cerebral angiography after embolization of AVM showed different results. In one patient, AVM was totally occluded after three sessions and in second case AVM was occluded in a single session. The rate of occlusion in other two cases was estimated between 70% in 80%. Both of these two patients underwent surgery. One patient is still in the process of treatment. Endovascular treatment of cerebral AVMs with superselective embolization with liquid cyanoacrilyc adhesive agent is a safe and effective alternative treatment paths next to microsurgery. Endovascular treatment in combination with radiosurgery could become the method of choice in the therapy of cerebral AVMs in the future. (author)

  10. Endovascular therapy of abdominal aortic aneurysm: results of a mid-term follow-up

    International Nuclear Information System (INIS)

    Pitton, M.B.; Schweitzer, H.; Herber, S.; Thelen, M.; Schmiedt, W.; Neufang, A.; Dueber, C.

    2003-01-01

    Prospective study to evaluate clinical results and complications of endovascular abdominal aortic aneurysm treatment in a mid-term follow-up. Materials and methods: A total of 122 patients (9 females, 113 males, average age 70.0±7,9 years) with abdominal aortic aneurysms were treated with stent grafts (53 Vanguard or Stentor endografts, 69 Talent endografts). Group I consisted of 40 patients who had all aortic tributaries of the aneurysm sac occluded prior to endovalscular grafting, either spontaneously by parietal thrombosis or by selective coil embolization of the respective ostia preserving collateral circulation distal to the vessel occlusion. Group II consisted of 82 patients and included all cases without or with incomplete coil embolization with at least one patent vessel. Stent grafting was performed in general anesthesia in the first 21 patients, followed by peridural anesthesia in 15 cases, and local anesthesia with conscious sedation in 86 cases. The results were evaluated with Spiral-CT, MRI and radiographs of the endovascular graft, with follow-up examinations obtained at 3, 6, 12 months, and every year - Implantation was successfully completed in all cases without primary conversion surgery, laparotomy or any significant complication. Mean follow-up was 29±21 months (maximum 82 months). The 30-day mortality was 0,8% due to a myocardial infarction 3 days after discharge from the hospital. A total of 47 re-interventions were performed in 29 patients (23.8%), with 35 re-interventions in 18 cases with Vanguard or Stentor endografts and 12 re-interventions in 11 patients with Talent endografts. 23 percutaneous re-interventions included distal graft extension (n=11), Wallstent for kinking and limb stenosis (n=3), and secondary coil embolization of collateral vessels (n=9). 24 surgical re-interventions included proximal graft extension (n=6), new endovascular grafts (n=3), surgical clipping of lumbar and mesenteric artery branches for type-II endoleaks

  11. Early endovascular treatment of superior mesenteric occlusion secondary to thromboemboli.

    Science.gov (United States)

    Jia, Z; Jiang, G; Tian, F; Zhao, J; Li, S; Wang, K; Wang, Y; Jiang, L; Wang, W

    2014-02-01

    To evaluate our early experience with endovascular revascularization in patients with acute thromboembolic occlusion of the superior mesenteric artery (SMA). A retrospective review was conducted of all patients who underwent endovascular revascularization for acute thromboembolic SMA occlusion from May 2005 to May 2012. Endovascular revascularization was performed using aspiration, intra-arterial thrombolysis, and adjunctive stent-placement techniques. Laparotomy was performed if the patient developed clinical signs of advanced bowel ischemia after endovascular procedure. Twenty-one patients underwent endovascular revascularization for acute thromboembolic SMA occlusion. All presented with acute-onset abdominal pain. Three patients had rebound tenderness before the procedure. Computed tomography angiography revealed complete occlusion in seven cases and incomplete occlusion in 14 cases, with no evidence of free gas or bowel necrosis. The median duration from onset of symptoms to revascularization was 8.7 ± 4.1 hours (range, 2-18 hours). Completely successful endovascular revascularization occurred in six cases (aspiration alone, 3 cases; combined aspiration and urokinase, 3 cases); partial success was achieved in 15 cases (aspiration alone, 4 cases; combined aspiration and urokinase, 10 cases; and combined aspiration, urokinase, and stent placement, 1 case). Laparotomy was required in five patients, all of whom had SMA main trunk complete occlusion and required small bowel resection. The 30-day mortality for all patients was 9.5%. During a median follow-up of 26 months, 15 patients remained asymptomatic, three patients reported occasional abdominal pain, and one patient had temporary short-bowel syndrome. Percutaneous revascularization is a promising alternative to surgery for acute SMA occlusion in selected patients who have no signs of advanced bowel ischemia. Early diagnosis followed by prompt endovascular intervention with close postprocedural monitoring is

  12. Midterm outcome of EndoAnchors for the prevention of endoleak and stent-graft migration in patients with challenging proximal aortic neck anatomy.

    Science.gov (United States)

    Jordan, William D; de Vries, Jean-Paul P M; Ouriel, Kenneth; Mehta, Manish; Varnagy, David; Moore, William M; Arko, Frank R; Joye, James; Henretta, John

    2015-04-01

    To explore the use of EndoAnchors as an adjunct to endovascular abdominal aortic aneurysm repair for prevention of proximal neck complications in patients with challenging neck anatomy. Over a 28-month period, 208 patients (159 men; mean age 72±8 years) were enrolled in the ANCHOR prospective, multicenter registry (ClinicalTrials.gov; identifier NCT01534819) for prophylaxis against proximal neck complications. Patients were eligible when, in the opinion of the investigators, they were at increased risk for type Ia endoleak or migration owing to a hostile neck (length 28 mm, angulation >60°, mural thrombus or calcium >2 mm in thickness or >180° in circumference, or conical shape). Overall, 123/157 (78.3%) patients met the criteria for a hostile neck according to core laboratory assessment of 157 adequate preoperative computed tomographic (CT) images. Implantation of EndoAnchors was technically successful in 204/208 (98.1%) patients. The frequency of fracture was 0.3% (3/1118); there were no clinical sequelae associated with the fractures. Over the mean 14-month follow-up, 95.2% of patients were alive, and no deaths were attributable to EndoAnchors. There were no ruptures, migrations, or open surgical conversions. Aneurysm-related reinterventions were performed in 8 (3.8%) patients. Among 130 patients with postprocedure contrast CT studies, core laboratory analysis identified 2 (1.5%) patients with type Ia endoleaks. Aneurysm sac diameter decreased >5 mm in 42.9% of patients with CT scans at or beyond 1 year; 1.6% of patients developed sac enlargement >5 mm. Prophylactic EndoAnchor use for challenging aortic neck anatomy was associated with satisfactory midterm results. © The Author(s) 2015.

  13. Celiac Trunk Embolization, as a Means of Elongating Short Distal Descending Thoracic Aortic Aneurysm Necks, Prior to Endovascular Aortic Repair

    International Nuclear Information System (INIS)

    Belenky, Alexander; Haddad, Menashe; Idov, Igor; Knizhnik, Michael; Litvin, Sergey; Bachar, Gil N.; Atar, Eli

    2009-01-01

    The purpose of this study was to report our experience in elongating short distal necks of descending thoracic aortic aneurysms (DTAAs) by coil embolization of the celiac trunk prior to endovascular aneurysm repair (EVAR). During 6 years seven patients (five men and two women; mean age, 74) who had DTAAs with short distal necks unsuitable for conventional EVAR, and well patent superior and inferior mesenteric arteries based on CT, were treated in one session with EVAR after the celiac trunk was coil embolized to elongate the neck. All patients were followed by CT every 3 months in the first year and every 6 months thereafter. Technical success was achieved in all patients, and no early or late ischemic complications were noted. No procedural complications occurred and good aneurysm sealing was obtained in all patients. Three endoleaks were identified after 3 months (one patient) and 6 months (two patients); all were treated successfully with insertion of an additional stent-graft. In patients with DTAAs who are candidates for EVAR but have short aneurysm distal necks, celiac trunk embolization-only if the superior and inferior mesenteric arteries are patent-is a good and safe way to elongate the neck and enable EVAR.

  14. Treatment of a Common Iliac Aneurysm by Endovascular Exclusion Using the Amplatzer Vascular Plug and Femorofemoral Crossover Graft

    International Nuclear Information System (INIS)

    Coupe, Nicholas J.; Ling, Lynn; Cowling, Mark G.; Asquith, John R.; Hopkinson, Gregory B.

    2009-01-01

    We report our initial experience using the Amplatzer Vascular Plug II (AVP2) in the treatment of a left common iliac aneurysm. Following investigation by computerized tomographic angiography and catheter angiography, a 79-year-old man was found to have a markedly tortuous iliac system, with a left common iliac artery aneurysm that measured 48 mm in maximal diameter. Due to the patient's age and comorbidities the surgical opinion was that conventional open repair was not suitable. However, due to the tortuous nature of the aneurysm and iliac vessels, standard endovascular repair, using either a bifurcated or an aorto-uni-iliac stent graft, was also not possible. A combined approach was used by embolizing the ipsilateral internal iliac artery using coils and excluding the aneurysm using two AVP2 occlusion devices, followed by femorofemoral crossover grafting. Total aneurysm occlusion was achieved using this method and this allowed the patient to have a much less invasive surgical procedure than with conventional open repair of common iliac aneurysms, thus avoiding potential comorbidity and mortality.

  15. Disección de aorta: Aspectos básicos y manejo endovascular Aortic dissection: Basic aspects and endovascular management

    Directory of Open Access Journals (Sweden)

    Nicolás I Jaramillo

    2005-08-01

    Full Text Available El tratamiento de la patología aórtica torácica se complica por la asociación con una alta mortalidad en la reparación quirúrgica, y al mismo tiempo fragilidad y gran comorbilidad en los adultos de edad avanzada. En la búsqueda por reducir la incidencia de resultados negativos, en la década pasada se introdujo la técnica de intervención por la vía de la mínima invasión, con la colocación de dispositivos del tipo stent vía endovascular. La técnica, originalmente descrita por Parodi e inicialmente diseñada para uso en la corrección de aneurismas de aorta abdominal, ha sido adoptada para el uso en la patología aórtica torácica. El mejoramiento en el entendimiento de la fisiopatología y la historia natural de la enfermedad de la aorta torácica y el análisis de los resultados, han facilitado la toma de decisiones en cuanto al tratamiento en términos del tiempo de la intervención apropiada. El tratamiento de la disección de la aorta torácica con el uso de stent endovascular, es uno de los más recientes avances en el tratamiento y hoy recibe una atención especial, al punto que es una alternativa menos invasiva; incluso la tecnología está apenas en sus primeras etapas y en los últimos años se han mejorado significativamente el diseño y el sistema de liberación de estos dispositivos endovasculares conocidos como stent-grafts. Estas prótesis se utilizan de forma creciente en el tratamiento de aneurismas, disecciones, rupturas traumáticas, úlceras penetradas gigantes y hematomas intramurales de la aorta torácica descendente, con buenos resultados tanto tempranos como a mediano plazo. La poca frecuencia, la alta complejidad y la severidad de la patología, y al mismo tiempo el alto riesgo teórico de las complicaciones que se pueden generar, deben mantener cauto al operador, especialmente cuando esta técnica se aplica en pacientes jóvenes. De manera conceptual la solución por la vía endoluminal en las fases agudas

  16. The financial implications of endovascular aneurysm repair in the cost containment era.

    Science.gov (United States)

    Stone, David H; Horvath, Alexander J; Goodney, Philip P; Rzucidlo, Eva M; Nolan, Brian W; Walsh, Daniel B; Zwolak, Robert M; Powell, Richard J

    2014-02-01

    Endovascular aneurysm repair (EVAR) is associated with significant direct device costs. Such costs place EVAR at odds with efforts to constrain healthcare expenditures. This study examines the procedure-associated costs and operating margins associated with EVAR at a tertiary care academic medical center. All infrarenal EVARs performed from April 2011 to March 2012 were identified (n = 127). Among this cohort, 49 patients met standard commercial instruction for use guidelines, were treated using a single manufacturer device, and billed to Medicare diagnosis-related group (DRG) 238. Of these 49 patients, net technical operating margins (technical revenue minus technical cost) were calculated in conjunction with the hospital finance department. EVAR implant costs were determined for each procedure. DRG 238-associated costs and length of stay were benchmarked against other academic medical centers using University Health System Consortium 2012 data. Among the studied EVAR cohort (age 75, 82% male, mean length of stay, 1.7 days), mean technical costs totaled $31,672. Graft implants accounted for 52% of the allocated technical costs. Institutional overhead was 17% ($5495) of total technical costs. Net mean total technical EVAR-associated operating margins were -$4015 per procedure. Our institutional costs and length of stay, when benchmarked against comparable centers, remained in the lowest quartile nationally using University Health System Consortium costs for DRG 238. Stent graft price did not correlate with total EVAR market share. EVAR is currently associated with significant negative operating margins among Medicare beneficiaries. Currently, device costs account for over 50% of EVAR-associated technical costs and did not impact EVAR market share, reflecting an unawareness of cost differential among surgeons. These data indicate that EVAR must undergo dramatic care delivery redesign for this practice to remain sustainable. Copyright © 2014 Society for Vascular

  17. Endovascular Treatment Strategies in Aortoiliac Occlusion

    International Nuclear Information System (INIS)

    Ozkan, Ugur; Oguzkurt, Levent; Tercan, Fahri; Gumus, Burcak

    2009-01-01

    The aim of this study was to report our experience in endovascular treatment of total aortoiliac occlusion. Five patients who underwent endovascular recanalization procedures including manual aspiration thrombectomy, balloon angioplasty, and stent placement for total aortoiliac occlusion in a 4-year period were reviewed retrospectively. The mean age of patients was 51 years (range, 43 to 58 years). All patients had abdominal aorta and bilateral common iliac artery occlusion with or without external iliac artery occlusion. All patients either had a contraindication to surgery or refused it. Initial technical success was obtained in four of five (80%) patients. Endovascular techniques were successful in four patients who had good distal runoff and short-segment aortoiliac occlusion, but failed in a patient who had the worst distal runoff and long-segment aortoiliac occlusion. We observed two major complications, one of which was bilateral rupture of the common iliac arteries treated with covered stent placement. Another patient had extension of intra-aortic thrombus into the iliac stent after primary stenting. This was successfully treated with manual aspiration thrombectomy. Aortic and iliac stents remained patent during the follow-up period (median, 18 months; range, 3 to 26 months) in four patients. Primary patency rates at 6, 12, and 24 months were all 80%. In conclusion, endovascular treatment can be an alternative for aortoiliac occlusion in selected patients. Short- to midterm follow-up so far is satisfactory. Removal of intra-aortic thrombus with manual aspiration thrombectomy before balloon angioplasty and/or stenting is possible and a good alternative to thrombolysis.

  18. Endovascular treatment of head and neck arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Dmytriw, A.A. [University Health Network, Joint Department of Medical Imaging, Toronto, Ontario (Canada); Ter Brugge, K.G.; Krings, T.; Agid, R. [Toronto Western Hospital, Division of Neuroradiology, Department of Medical Imaging, Toronto, Ontario (Canada)

    2014-03-15

    Head and neck arteriovenous malformations (H and N AVM) are associated with considerable clinical and psychosocial burden and present a significant treatment challenge. We evaluated the presentation, response to treatment, and outcome of patients with H and N AVMs treated by endovascular means at our institution. Patients with H and N AVMs treated by endovascular means from 1984 to 2012 were evaluated retrospectively. These included AVMs involving the scalp, orbit, maxillofacial, and upper neck localizations. Patient's clinical files, radiological images, catheter angiograms, and surgical reports were reviewed. Eighty-nine patients with H and N AVMs (46 females, 43 males; 48 small, 41 large) received endovascular therapy. The goals of treatment were curative (n = 30), palliative (n = 34), or presurgical (n = 25). The total number of endovascular treatment sessions was 244 (average of 1.5 per patient). The goal of treatment was met in 92.1 % of cases. Eventual cure was achieved in 42 patients accounting for 58.4 % (52/89) of all patients who underwent treatment for any goal. Twenty-eight of these patients were cured by embolization alone (28/89, 31.4 %) of which 18 were single-hole AVFs. Twenty-four were cured by planned surgical excision after presurgical embolization (24/89, 27 %). Seven patients (7/89, 7.2 %) suffered transient and two (2/89, 2.2 %) permanent endovascular treatment complications. Endovascular treatment is effective for H and N AVMs and relatively safe. It is particularly effective for symptom palliation and presurgical aid. Embolization is curative mostly in small lesions and single-hole fistulas. In patients with large non-curable H and N AVMs, endovascular therapy is often the only palliative option. (orig.)

  19. Headache and endovascular procedures.

    Science.gov (United States)

    de Biase, Stefano; Longoni, Marco; Gigli, Gian Luigi; Agostoni, Elio

    2017-05-01

    The International Classification of Headache Disorders (ICHD-3 beta) includes headache attributed to intracranial endovascular procedures (EVPs). The aim of this review is to describe the clinical and pathophysiological aspects of headache related to vascular lesions and EVPs. Current studies regarding this issue are contradictory, although generally favouring headache improvement after EVPs. Further large studies are needed to adequately assess the effect of EVPs on headache.

  20. Endovascular treatment in pregnancy

    International Nuclear Information System (INIS)

    Ishii, Akira; Miyamoto, Susumu

    2013-01-01

    There is an increased risk of stroke during pregnancy and the puerperium. Decisions should be made immediately upon transfer to each institution, particularly with respect to when and how to treat the patient. This review highlights the feasibility of endovascular treatment in pregnancy. Most of the pharmaceutical agents and therapeutic devices used in clinical practice can be utilized in pregnant patients. Comprehensive information on the benefits and risks of treatment should be explained to the patient and her family, with particular attention to the safety of the mother and fetus. Radiation exposure to the fetus is also a concern; the hazard can be minimized with optimal protection. Several studies have demonstrated that conventional procedures do not cause serious radiation exposure exceeding the threshold of safety to the fetus. Endovascular therapy can be safely performed for the treatment of acute stroke as in non-pregnant patients with adequate attention to pharmaceutical agents and shielding from radiation. In contrast to therapy for acute stroke, preventive endovascular treatment for asymptomatic lesions remains controversial. Several conditions, such as cerebral aneurysms and arteriovenous malformations, are known to bleed more frequently in pregnancy, but whether the benefits of preventive treatment outweigh the associated risks is unknown. The decision for preventive treatment should be carefully made on a case-by-case basis after extensive discussion with the patient. (author)

  1. [Endovascular surgery in the war].

    Science.gov (United States)

    Reva, V A; Samokhvalov, I M

    2015-01-01

    Rapid growth of medical technologies has led to implementation of endovascular methods of diagnosis and treatment into rapidly developing battlefield surgery. This work based on analysing all available current publications generalizes the data on using endovascular surgery in combat vascular injury. During the Korean war (1950-1953) American surgeons for the first time performed endovascular balloon occlusion of the aorta - the first intravascular intervention carried out in a zone of combat operations. Half a century thereafter, with the beginning of the war in Afghanistan (2001) and in Iraq (2003) surgeons of central hospitals of the USA Armed Forces began performing delayed endovascular operations to the wounded. The development of technologies, advent of mobile angiographs made it possible to later on implement high-tech endovascular interventions in a zone of combat operations. At first, more often they performed implantation of cava filters, somewhat afterward - angioembolization of damaged accessory vessels, stenting and endovascular repair of major arteries. The first in the theatre of war endovascular prosthetic repair of the thoracic aorta for severe closed injury was performed in 2008. Russian experience of using endovascular surgery in combat injuries is limited to diagnostic angiography and regional intraarterial perfusion. Despite the advent of stationary angiographs in large hospitals of the RF Ministry of Defence in the early 1990s, endovascular operations for combat vascular injury are casuistic. Foreign experience in active implementation of endovascular technologies to treatment of war-time injuries has substantiated feasibility of using intravascular interventions in tertiary care military hospitals. Carrying out basic training courses on endovascular surgery should become an organic part of preparing multimodality general battlefield surgeons rendering care on the theatre of combat operations.

  2. Total Endovascular Aortic Repair in a Patient with Marfan Syndrome.

    Science.gov (United States)

    Amako, Mau; Spear, Rafaëlle; Clough, Rachel E; Hertault, Adrien; Azzaoui, Richard; Martin-Gonzalez, Teresa; Sobocinski, Jonathan; Haulon, Stéphan

    2017-02-01

    The aim of this study is to describe a total endovascular aortic repair with branched and fenestrated endografts in a young patient with Marfan syndrome and a chronic aortic dissection. Open surgery is the gold standard to treat aortic dissections in patients with aortic disease and Marfan syndrome. In 2000, a 38-year-old man with Marfan syndrome underwent open ascending aorta repair for an acute type A aortic dissection. One year later, a redo sternotomy was performed for aortic valve replacement. In 2013, the patient presented with endocarditis and pulmonary infection, which necessitated tracheostomy and temporary dialysis. In 2014, the first stage of the endovascular repair was performed using an inner branched endograft to exclude a 77-mm distal arch and descending thoracic aortic aneurysm. In 2015, a 63-mm thoracoabdominal aortic aneurysm was excluded by implantation of a 4-fenestrated endograft. Follow-up after both endovascular repairs was uneventful. Total aortic endovascular repair was successfully performed to treat a patient with arch and thoraco-abdominal aortic aneurysm associated with chronic aortic dissection and Marfan syndrome. The postoperative images confirmed patency of the endograft and its branches, and complete exclusion of the aortic false lumen. Endovascular repair is a treatment option in patients with connective tissue disease who are not candidates for open surgery. Long-term follow-up is required to confirm these favorable early outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Predictive factors for cerebrovascular accidents after thoracic endovascular aortic repair.

    Science.gov (United States)

    Mariscalco, Giovanni; Piffaretti, Gabriele; Tozzi, Matteo; Bacuzzi, Alessandro; Carrafiello, Giampaolo; Sala, Andrea; Castelli, Patrizio

    2009-12-01

    Cerebrovascular accidents are devastating and worrisome complications after thoracic endovascular aortic repair. The aim of this study was to determine cerebrovascular accident predictors after thoracic endovascular aortic repair. Between January 2001 and June 2008, 76 patients treated with thoracic endovascular aortic repair were prospectively enrolled. The study cohort included 61 men; mean age was 65.4 +/- 16.8 years. All patients underwent a specific neurologic assessment on an hourly basis postoperatively to detect neurologic deficits. Cerebrovascular accidents were diagnosed on the basis of physical examination, tomography scan or magnetic resonance imaging, or autopsy. Cerebrovascular accidents occurred in 8 (10.5%) patients, including 4 transient ischemic attack and 4 major strokes. Four cases were observed within the first 24-hours. Multivariable analysis revealed that anatomic incompleteness of the Willis circle (odds ratio [OR] 17.19, 95% confidence interval [CI] 2.10 to 140.66), as well as the presence of coronary artery disease (OR 6.86, 95 CI% 1.18 to 40.05), were independently associated with postoperative cerebrovascular accident development. Overall hospital mortality was 9.2%, with no significant difference for patients hit by cerebrovascular accidents (25.0% vs 7.3%, p = 0.102). Preexisting coronary artery disease, reflecting a severe diseased aorta and anomalies of Willis circle are independent cerebrovascular accident predictors after thoracic endovascular aortic repair procedures. A careful evaluation of the arch vessels and cerebral vascularization should be mandatory for patients suitable for thoracic endovascular aortic repair.

  4. Retrograde Ascending Dissection After Thoracic Endovascular Aortic Repair Combined With the Chimney Technique and Successful Open Repair Using the Frozen Elephant Trunk Technique.

    Science.gov (United States)

    Hirano, Koji; Tokui, Toshiya; Nakamura, Bun; Inoue, Ryosai; Inagaki, Masahiro; Maze, Yasumi; Kato, Noriyuki

    2018-01-01

    The chimney technique can be combined with thoracic endovascular aortic repair (TEVAR) to both obtain an appropriate landing zone and maintain blood flow of the arch vessels. However, surgical repair becomes more complicated if retrograde type A aortic dissection occurs after TEVAR with the chimney technique. We herein report a case involving a 73-year-old woman who developed a retrograde ascending dissection 3 months after TEVAR for acute type B aortic dissection. To ensure an adequate proximal sealing distance, the proximal edge of the stent graft was located at the zone 2 level and an additional bare stent was placed at the left subclavian artery (the chimney technique) at the time of TEVAR. Enhanced computed tomography revealed an aortic dissection involving the ascending aorta and aortic arch. Surgical aortic repair using the frozen elephant trunk technique was urgently performed. The patient survived without stroke, paraplegia, renal failure, or other major complications. Retrograde ascending dissection can occur after TEVAR combined with the chimney technique. The frozen elephant trunk technique is useful for surgical repair in such complicated cases.

  5. Salvage of bilateral renal artery occlusion after endovascular aneurysm repair with open splenorenal bypass

    Directory of Open Access Journals (Sweden)

    Samuel Jessula, MDCM

    2017-09-01

    Full Text Available We report renal salvage maneuvers after accidental bilateral renal artery coverage during endovascular aneurysm repair of an infrarenal abdominal aortic aneurysm. A 79-year-old man with an infrarenal abdominal aortic aneurysm was treated with endovascular aneurysm repair. Completion angiography demonstrated coverage of the renal arteries. Several revascularization techniques were attempted, including endograft repositioning and endovascular stenting through the femoral and brachial approach. The patient eventually underwent open splenorenal bypass with a Y Gore-Tex graft (W. L. Gore & Associates, Flagstaff, Ariz. After 3 months, computed tomography showed no evidence of endoleak and patent renal arteries. Renal function was well maintained, and the patient did not require dialysis.

  6. Open surgery versus endovascular approach in treatment of extracranial carotid artery aneurysms.

    Science.gov (United States)

    Ni, Leng; Weng, Huiling; Pu, Zuo; Zheng, Yuehong; Liu, Bao; Ye, Wei; Zeng, Rong; Liu, Changwei

    2018-05-01

    The objective of this study was to investigate and to compare the early and long-term results of open surgery with endovascular intervention in the treatment of extracranial carotid artery aneurysms (ECCAs). A retrospective review of patients diagnosed with ECCAs who underwent open surgical or endovascular treatment from 1997 to 2017 was performed. Clinical characteristics, aneurysm profile, and treatment outcomes were recorded. Early results (open surgery; endovascular repair was performed on 16 patients (33.3%). The 30-day stroke or transient ischemic attack rate was not significantly different between the open group (6.3% [2/32]) and the endovascular group (0% [0/16]; P = .307). Cranial nerve injuries occurred in eight patients in the open group (25%) and in no patient in the endovascular group (0%; P = .029). Median length of stay was significantly longer in the open group than in the endovascular group (20 vs 14 days, respectively; P = .013). Median follow-up was 46 months (range, 0-20 years), and no aneurysm-related death occurred during this period. Overall survival rates at 5 years were 88.7% (standard error [SE], 0.08) in the open group and 91.7% (SE, 0.08) in the endovascular group (P = .319; log-rank, .992). For the same time interval, stroke-free survival rates were 85.2% (SE, 0.10) in the open group and 92.2% (SE, 0.07) in the endovascular group (P = .653; log-rank, .201). One patient (1/28 [3.6%]) in the open group and two patients (2/16 [12.5%]) in the endovascular group underwent endovascular reinterventions because of restenosis during the follow-up period. Reintervention-free survival rates were 90.9% in the open group (SE, 0.09) and 69.2% in the endovascular group (SE, 0.21; P = .082; log-rank, 3.016). In this single-institutional experience, both operative and endovascular interventions for ECCAs provided acceptable early and 5-year results. The endovascular approach had significantly less cranial nerve injury and shorter length of

  7. Early and mid-term results in the endovascular treatment of popliteal aneurysms with the multilayer flow modulator.

    Science.gov (United States)

    Ucci, Alessandro; Curci, Ruggiero; Azzarone, Matteo; Bianchini Massoni, Claudio; Bozzani, Antonio; Marcato, Carla; Marone, Enrico Maria; Perini, Paolo; Tecchio, Tiziano; Freyrie, Antonio; Argenteri, Angelo

    2018-01-01

    Background The endovascular approach became an alternative to open surgical treatment of popliteal artery aneurysm over the last few years. Heparin-bonded stent-grafts have been employed for endovascular popliteal artery aneurysm repair, showing good and stable results. Only few reports about the use of multilayer flow modulator are available in literature, providing small patient series and short follow-up. The aim of this study is to report the outcomes of patients with popliteal artery aneurysm treated with the multilayer flow modulator in three Italian centres. Methods We retrospectively analysed a series of both symptomatic and asymptomatic patients with popliteal artery aneurysm treated with the multilayer flow modulator from 2009 to 2015. Follow-up was undertaken with clinical and contrast-enhanced ultrasound examinations at 1, 6 and 12 months, and yearly thereafter. Computed tomography angiography was performed in selected cases. Primary endpoints were aneurysm sac thrombosis; freedom from sac enlargement and primary, primary-assisted and secondary patency during follow-up. Secondary endpoints were technical success, collateral vessels patency, limb salvage and aneurysm-related complications. Results Twenty-three consecutive patients (19 males, age 72 ± 11) with 25 popliteal artery aneurysms (mean diameter 23 mm ± 1, 3 symptomatic patients) were treated with 40 multilayer flow modulators during the period of the study. Median follow-up was 22.6 ± 16.7 months. Complete aneurysm thrombosis occurred in 92.9% of cases (23/25 cases) at 18 months. Freedom from sac enlargement was 100% (25/25 cases) with 17 cases of aneurysm sac shrinkage (68%). At 1, 6, 12 and 24 months, estimated primary patency was 95.7%, 87.3%, 77% and 70.1%, respectively. At the same intervals, primary-assisted patency was 95.7%, 91.3%, 86% and 86%, respectively, and secondary patency was 100%, 95.7%, 90.3% and 90.3%, respectively. Technical success was 100%. The collateral

  8. ENDOVASCULAR HEMOSTASIS IN UTERINE BLEEDING IN PATIENTS WITH UTERINE LEIOMYOMA

    Directory of Open Access Journals (Sweden)

    M. M. Damirov

    2017-01-01

    Full Text Available We report results of treatment for 72 patients with uterine leiomyoma (LM of various sizes and location, who had arrived with excessive uterine bleeding. All patients underwent urgent or urgently-delayed endovascular hemostasis by performing uterine arteries embolization (UAE. We analyzed clinical features of the disease after UAE in various sizes of tumors and studied immediate and long-term results of UAE in patients with LM.

  9. Endovascular and surgical treatment of spinal dural arteriovenous fistulas

    International Nuclear Information System (INIS)

    Andres, Robert H.; University of Berne; Stanford University Medical Center, Department of Neurosurgery, Stanford, CA; University of Berne; Barth, Alain; Medical University of Graz, Department of Neurosurgery, Graz; University of Berne; Guzman, Raphael; Stanford University Medical Center, Department of Neurosurgery, Stanford, CA; University of Berne; Remonda, Luca; El-Koussy, Marwan; Schroth, Gerhard; University of Berne; Seiler, Rolf W.; Widmer, Hans R.; University of Berne

    2008-01-01

    The aim of this retrospective study was to evaluate the clinical outcome of patients with spinal dural arteriovenous fistulas (SDAVFs) that were treated with surgery, catheter embolization, or surgery after incomplete embolization. The study included 21 consecutive patients with SDAVFs of the thoracic, lumbar, or sacral spine who were treated in our institution from 1994 to 2007. Thirteen patients were treated with catheter embolization alone. Four patients underwent hemilaminectomy and intradural interruption of the fistula. Four patients were treated by endovascular techniques followed by surgery. The clinical outcome was assessed using the modified Aminoff-Logue scale (ALS) for myelopathy and the modified Rankin scale (MRS) for general quality of life. Patient age ranged from 44 to 77 years (mean 64.7 years). Surgical as well as endovascular treatment resulted in a significant improvement in ALS (-62.5% and -31.4%, respectively, p<0.05) and a tendency toward improved MRS (-50% and -32%, respectively) scores. Patients that underwent surgery after endovascular treatment due to incomplete occlusion of the fistula showed only a tendency for improvement in the ALS score (-16.7%), whereas the MRS score was not affected. We conclude that both endovascular and surgical treatment of SDAVFs resulted in a good and lasting clinical outcome in the majority of cases. In specific situations, when a secondary neurosurgical approach was required after endovascular treatment to achieve complete occlusion of the SDAVF, the clinical outcome was rather poor. The best first line treatment modality for each individual patient should be determined by an interdisciplinary team. (orig.)

  10. The repair of a type Ia endoleak following thoracic endovascular aortic repair using a stented elephant trunk procedure.

    Science.gov (United States)

    Qi, Rui-Dong; Zhu, Jun-Ming; Liu, Yong-Min; Chen, Lei; Li, Cheng-Nan; Xing, Xiao-Yan; Sun, Li-Zhong

    2018-04-01

    Type Ia endoleaks are not uncommon complications that occur after thoracic endovascular aortic repair (TEVAR). Because aortic arch vessels prevent extension of the landing zone, it is very difficult to manipulate a type Ia endoleak using an extension cuff or stent-graft, especially when the aortic arch is involved. Here, we retrospectively review our experience of surgical treatment of type Ia endoleak after TEVAR using a stented elephant trunk procedure. From July 2010 to August 2016, we treated 17 patients diagnosed with a type Ia endoleak following TEVAR using stented elephant trunk procedure. The mean age of our patients was 52 ± 8 years. The mean interval between TEVAR and the open surgical repair was 38 ± 43 months. All cases of type Ia endoleak (100%) were repaired successfully. There were no in-hospital deaths. One case required reintubation and continuous renal replacement therapy due to renal failure; this patient recovered smoothly before discharge. One other patient suffered a stroke and renal failure and did not fully recover following discharge, or follow-up. During follow-up, there were 3 deaths. Acceptable results were obtained using a stented elephant trunk procedure in patients with a type Ia endoleak after TEVAR. This technique allowed us to repair the proximal aortic arch lesions, surgically correct the type Ia endoleak, and promote false lumen thrombosis in the distal aorta. Implantation of a stented elephant trunk, with or without a concomitant aortic arch procedure, is an alternative approach for this type of lesion. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  11. Are there fewer complications with third generation endografts in endovascular aneurysm repair?

    DEFF Research Database (Denmark)

    Jayia, P; Constantinou, J; Morgan-Rowe, L

    2013-01-01

    . The majority of these endostents are now withdrawn from the commercial market. However, these patients need lifelong surveillance because of a considerable risk of late complications. The materials used in the stent-graft vary with each manufacturer. Low porous fabric, suprarenal fixation and low profile...... devices led to the development of the second generation stent-grafts. The improvements with regards to the delivery systems, enabled reposition of the top-stent following deployment in some devices. The number of devices commercially available increased with the second generation. The third generation...

  12. ORIGINAL ARTICLES Endovascular treatment of cerebral ...

    African Journals Online (AJOL)

    With this in mind we looked at the costs ... of surgical or endovascular disposables. ... surgical versus endovascular treatment were 18 and 6 days .... 329: 527) gives a list of nine risk factors which explain most heart attacks: an abnormal ratio.

  13. Endovascular treatment of basilar tip aneurysms associated with moyamoya disease

    International Nuclear Information System (INIS)

    Arita, K.; Kurisu, K.; Ohba, S.; Shibukawa, M.; Kiura, H.; Sakamoto, S.; Uozumi, T.; Nakahara, T.

    2003-01-01

    We report the efficacy and safety of endovascular treatment of basilar tip aneurysms (BTA) in five patients with moyamoya disease. The patients underwent intra-aneurysmal embolisation with detachable platinum coils. Three BTA presented with subarachnoid haemorrhage (SAH); the other two were asymptomatic. In four cases, one embolisation procedure produced >95% angiographic obliteration of the aneurysm. In the other patient, 80-90% obliteration was achieved initially, but due to growth of the residual aneurysm, the procedure was repeated 7 months later. Two patients experienced transient oculomotor paresis as a procedure-related complication. Mean follow-up was 43.6±34.0 months (range 8-92 months). One patient died of putaminal haemorrhage unrelated to the aneurysm 15 months after embolisation. The other four had no subsequent SAH and survived without sequelae. Endovascular embolisation using detachable platinum coils proved to be a safe and efficient treatment modality for BTA associated with moyamoya disease. (orig.)

  14. Endovascular treatment of PICA aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Mukonoweshuro, W.; Laitt, R.D.; Hughes, D.G. [Radiology Dept., Greater Manchester Neurosciences Unit, Hope Hospital, Salford, Manchester (United Kingdom)

    2003-03-01

    Endovascular treatment of aneurysms of the posterior inferior cerebellar artery (PICA) avoids manipulation of the brainstem or lower cranial nerves and should therefore carry a lower risk of neurological morbidity than surgical clipping. We reviewed our experience of 23 patients with PICA aneurysms treated by endovascular occlusion with Guglielmi detachable coils and documented their long-term outcome on follow-up. We observed a 28 day procedure-related neurological morbidity of 13% (3/23 patients). One patient suffered permanent neurological complications. There were no procedure-related deaths. None of our patients suffered a re-bleed from their treated aneurysms. Our series shows endovascular treatment of ruptured PICA aneurysms to be safe and effective. (orig.)

  15. Endovascular Treatment of a Vertebral Artery Pseudoaneurysm in a Drug User

    International Nuclear Information System (INIS)

    Mourikis, Dimitrios; Chatziioannou, Achilleas; Doriforou, Ortansia; Skiadas, Vasilios; Koutoulidis, Vasilios; Katsenis, Konstantinos; Vlahos, Lampros

    2006-01-01

    A 26-year-old drug abuser who presented with sepsis was found to have a pseudoaneurysm in the left vertebral artery. This aneurysm was presumed to be post-traumatic, since the patient reported multiple attempts to inject drugs in the left jugular vein 15 days prior to admission. The pseudoaneurysm was treated effectively with stent-graft placement

  16. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenbruch, Georg, E-mail: gmuehlenbruch@ukaachen.de; Nikoubashman, Omid; Steffen, Bjoern; Dadak, Mete [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany); Palmowski, Moritz [RWTH Aachen University, Department of Nuclear Medicine, University Hospital (Germany); Wiesmann, Martin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany)

    2013-02-15

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  17. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    International Nuclear Information System (INIS)

    Mühlenbruch, Georg; Nikoubashman, Omid; Steffen, Björn; Dadak, Mete; Palmowski, Moritz; Wiesmann, Martin

    2013-01-01

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  18. Endovascular US: Adjunct to percutaneous atherectomy

    International Nuclear Information System (INIS)

    Schwarten, D.E.; Cutcliff, W.B.

    1987-01-01

    Percutaneous atherectomy with the Simpson atherectomy catheter has been performed at our institution since the third quarter of 1986. The first 45 patients underwent atherectomy with fluoroscopic guidance and multiplane documentary arteriography to assess the anatomic appearance of vessels after atherectomy and to assist in judging the completeness of the procedure. Each of the 45 patients underwent repeated cuts on each lesion until no further atheromatous specimens could be removed. Since late 1987, all lesions subjected to atherectomy have also been examined intraprocedure with an intraarterial US probe 0.040 inches in diameter fixed to a 0.040-inch guide wire and covered by a sonolucent radome. The US images were reviewed in real time and permitted much more accurate placement of the atherectomy catheter to effect more complete removal of the atheromatous material. It is anticipated that the use of the endovascular US device to accurately localize residual atheroma will result in more complete removal of atheroma, in turn decreasing the possibility of recurrence

  19. Endovascular Treatment of Totally Occluded Superior Mesenteric Artery by Retrograde Crossing via the Villemin Arcade

    International Nuclear Information System (INIS)

    Ferro, Carlo; Rossi, Umberto G.; Seitun, Sara; Bovio, Giulio; Fornaro, Rosario

    2013-01-01

    Chronic mesenteric ischemia (CMI) is a rare disorder that is commonly caused by progressive atherosclerotic stenosis or occlusion of one or more mesenteric arteries. Endovascular treatment for symptomatic CMI represents a viable option, especially in high-operative risk patients. We report a case of acute symptomatic CMI with chronic totally occlusion of the superior mesenteric artery (SMA) associated with significant stenosis of celiac trunk (CT) and inferior mesenteric artery (IMA) that underwent endovascular treatment of all the three mesenteric arteries: stenting of CT and IMA stenosis, and recanalization of the SMA occlusion by retrograde crossing via the Villemin arcade.

  20. Endovascular treatment of ruptured splenic artery aneurysm

    DEFF Research Database (Denmark)

    Bjerring, Ole Steen

    2008-01-01

    Splenic artery aneurysms (SAA) are traditionally treated surgically, but endovascular techniques are becoming increasingly popular. A 64 year-old male with chest pain and low blood pressure was admitted under suspicion of AMI. A CT scan showed a 56 mm SAA with signs of rupture. The patient...... was treated with endovascular embolisation of the SAA with coils. Blood pressure and haemoglobin levels were stabilized and the patient was discharged. In the case of rupture the treatment of choice seems to be endovascular....

  1. Early experience of endovascular treatment of peripheral vascular disease

    International Nuclear Information System (INIS)

    Ashraf, T.; Yousuf, K.; Karim, M.T.

    2015-01-01

    Atherosclerotic peripheral arterial disease (PAD) is prevalent affecting up to 16% of the population aged 55 years or older. Endovascular intervention for the treatment of limb ischemia has become the first line therapy but in Pakistan it is in embryonic stage due to dearth of trained persons and dedicated centres. This study was conducted to evaluate procedural success and early outcome of endovascular treatment of peripheral vascular disease. Methods: A prospective single arm multicentre study was conducted at the National Institute of Cardiovascular Disease and National Medical Centre, Karachi, Pakistan from January 2013 to June 2014. A total of 25 patients were enrolled in the study that underwent endovascular treatment. Out of 25 patients 23 (92%) had critical limb ischemia (CLI) as per TASC II classification (A to D) and 2 (8%) had carotid lesion with history of TIA. Patients of acute limb ischemia and stroke were excluded. Ankle brachial index (ABI) was classified as normal (0.9-1.3), mild (0.7-0.9), moderate (0.4-0.69), severe (<0.4). Outcome was taken as immediate success and symptoms, amputation of limb among CLI patients and incidence of stroke in patients with carotid artery lesion at end of six months. Results: Among aortoiliac, femoropopliteal and tibioperoneal lesions, tibioperoneal lesions at six months were found to be more symptomatic 6 (86%) and amputation 4 (57%). Two carotid lesions at follow up were asymptomatic without stroke. Conclusion: Endovascular treatment of peripheral vascular lesions, i.e., aortoiliac, femoropopliteal tibioperoneal and carotid lesions were satisfactory in immediate outcome. Tibioperoneal lesions were more symptomatic and limb amputation at six months. (author)

  2. Outcomes of Infrainguinal Revascularizations with Endovascular First Strategy in Critical Limb Ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Jens, Sjoerd, E-mail: s.jens@amc.uva.nl [Academic Medical Center, Department of Radiology (Netherlands); Conijn, Anne P., E-mail: a.p.conijn@amc.uva.nl; Frans, Franceline A., E-mail: f.a.frans@amc.uva.nl [Academic Medical Center, Departments of Radiology and Surgery (Netherlands); Nieuwenhuis, Marieke B. B., E-mail: m.b.nieuwenhuis@amc.uva.nl; Met, Rosemarie, E-mail: rosemariemet@hotmail.com [Academic Medical Center, Department of Radiology (Netherlands); Koelemay, Mark J. W., E-mail: m.j.koelemaij@amc.uva.nl; Legemate, Dink A., E-mail: d.a.legemate@amc.uva.nl [Academic Medical Center, Department of Surgery (Netherlands); Bipat, Shandra, E-mail: s.bipat@amc.uva.nl; Reekers, Jim A., E-mail: j.a.reekers@amc.uva.nl [Academic Medical Center, Department of Radiology (Netherlands)

    2015-06-15

    PurposeThis study was designed to study the outcome of infrainguinal revascularization in patients with critical limb ischemia (CLI) in an institution with a preference towards endovascular intervention first in patients with poor condition, unfavourable anatomy for surgery, no venous material for bypass, and old age.MethodsA prospective, observational cohort study was conducted between May 2007 and May 2010 in patients presenting with CLI. At baseline, the optimal treatment was selected, i.e., endovascular or surgical treatment. In case of uncertainty about the preferred treatment, a multidisciplinary team (MDT) was consulted. Primary endpoints were quality of life and functional status 6 and 12 months after initial intervention, assessed by the VascuQol and AMC Linear Disability Score questionnaires, respectively.ResultsIn total, 113 patients were included; 86 had an endovascular intervention and 27 had surgery. During follow-up, 41 % underwent an additional ipsilateral revascularisation procedure. For the total population, and endovascular and surgery subgroups, the VascuQol sum scores improved after 6 and 12 months (p < 0.01 for all outcomes) compared with baseline. The functional status improved (p = 0.043) after 12 months compared with baseline for the total population. Functional status of the surgery subgroup improved significantly after 6 (p = 0.031) and 12 (p = 0.044) months, but not that of the endovascular subgroup.ConclusionsOverall, the strategy of performing endovascular treatment first in patients with poor condition, unfavourable anatomy for surgery, no venous material for bypass, and old age has comparable or even slightly better results compared with the BASIL trial and other cohort studies. All vascular groups should discuss whether their treatment strategy should be directed at treating CLI patients preferably endovascular first and consider implementing an MDT to optimize patient outcomes.

  3. Identifying patients with AAA with the highest risk following endovascular repair.

    Science.gov (United States)

    Cadili, Ali; Turnbull, Robert; Hervas-Malo, Marilou; Ghosh, Sunita; Chyczij, Harold

    2012-08-01

    It has been demonstrated that endovascular repair of arterial disease results in reduced perioperative morbidity and mortality compared to open surgical repair. The rates of complications and need for reinterventions, however, have been found to be higher than that in open repair. The purpose of this study was to identify the predictors of endograft complications and mortality in patients undergoing endovascular abdominal aortic aneurysm (AAA) repair; specifically, our aim was to identify a subset of patients with AAA whose risk of periprocedure mortality was so high that they should not be offered endovascular repair. We undertook a prospective review of patients with AAA receiving endovascular therapy at a single institution. Collected variables included age, gender, date of procedure, indication for procedure, size of aneurysm (where applicable), type of endograft used, presence of rupture, American Society of Anesthesiologists (ASA) class, major medical comorbidities, type of anesthesia (general, epidural, or local), length of intensive care unit (ICU) stay, and length of hospital stay. These factors were correlated with the study outcomes (overall mortality, graft complications, morbidity, and reintervention) using univariate and multivariate logistic regression. A total of 199 patients underwent endovascular AAA repair during the study period. The ICU stay, again, was significantly correlated with the primary outcomes (death and graft complications). In addition, length of hospital stay greater than 3 days, also emerged as a statistically significant predictor of graft complications in this subgroup (P = .024). Survival analysis for patients with AAA revealed that age over 85 years and ICU stay were predictive of decreased survival. Statistical analysis for other subgroups of patients (inflammatory AAA or dissection) was not performed due to the small numbers in these subgroups. Patients with AAA greater than 85 years of age are at a greater risk of mortality

  4. Endovascular interventional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bartels, L W; Bakker, C J G

    2003-01-01

    Minimally invasive interventional radiological procedures, such as balloon angioplasty, stent placement or coiling of aneurysms, play an increasingly important role in the treatment of patients suffering from vascular disease. The non-destructive nature of magnetic resonance imaging (MRI), its ability to combine the acquisition of high quality anatomical images and functional information, such as blood flow velocities, perfusion and diffusion, together with its inherent three dimensionality and tomographic imaging capacities, have been advocated as advantages of using the MRI technique for guidance of endovascular radiological interventions. Within this light, endovascular interventional MRI has emerged as an interesting and promising new branch of interventional radiology. In this review article, the authors will give an overview of the most important issues related to this field. In this context, we will focus on the prerequisites for endovascular interventional MRI to come to maturity. In particular, the various approaches for device tracking that were proposed will be discussed and categorized. Furthermore, dedicated MRI systems, safety and compatibility issues and promising applications that could become clinical practice in the future will be discussed. (topical review)

  5. Endovascular Treatment for Aneurysmal Subarachnoid Hemorrhage with Neurogenic Pulmonary Edema in the Acute Stage.

    Science.gov (United States)

    Meguro, Toshinari; Tanabe, Tomoyuki; Muraoka, Kenichiro; Terada, Kinya; Hirotsune, Nobuyuki; Nishino, Shigeki

    2016-01-01

    Severe neurogenic pulmonary edema (NPE) can occur in a variety of brain insults, including subarachnoid hemorrhage (SAH), and severe case of NPE can cause devastating consequences. But the literature on the treatment strategy about aneurysmal SAH with NPE is very scant. We present that SAH patients with severe NPE, who were treated first by embolization of aneurysm followed by insertion of lumbar spinal drainage, had comparatively good outcome. We present 12 consecutive cases of aneurysmal SAH with NPE in the acute stage, which were treated by endovascular treatment between April 2002 and December 2012. We classified the patients according to the Hunt and Hess grading system as follows: grade-3 (1 patient), grade-4 (4 patients), and grade-5 (7 patients). All patients needed respiratory management, with the assistance of a ventilator, and underwent endovascular treatment for the ruptured aneurysms within 72 hours from onset. For all the patients, immediately after the endovascular treatment, we performed lumbar spinal drainage. The pulmonary edema disappeared rapidly after respiratory management and endovascular treatment. The outcomes were as follows: good recovery (GR; 3 patients), moderate disability (MD; 4 patients), severe disability (SD; 3 patients), and death (D; 2 patients). Five patients (42%) developed pneumonia, and we postponed extubation until recovery from pneumonia. The cause for severe disability and death was symptomatic vasospasm and primary brain damage. No patients had rebleeding from ruptured aneurysms. Endovascular treatment for ruptured aneurysm and placement of lumbar spinal drainage is an excellent treatment option for severe SAH with NPE.

  6. Endovascular interventions for TASC II D femoropopliteal lesions.

    Science.gov (United States)

    Baril, Donald T; Chaer, Rabih A; Rhee, Robert Y; Makaroun, Michel S; Marone, Luke K

    2010-06-01

    Advances in endovascular techniques have provided new options in the treatment of complex infrainguinal occlusive lesions. The purpose of this study was to evaluate outcomes of endovascular interventions on TransAtlantic InterSociety (TASC) II D femoropopliteal occlusive disease. All patients undergoing endovascular interventions for femoropopliteal occlusive disease between July 2004 and July 2009 were reviewed. Patient demographics, pre- and postprocedure ankle-brachial indices (ABI) and anatomic factors were analyzed. Outcomes evaluated included primary patency, assisted-patency, secondary patency, predictors of restenosis, and wound healing. Five hundred eighty-five limbs were treated during the period reviewed. The study group included 79 TASC D limbs in 74 patients (mean age 76.5 +/- 11.9 years, male sex: 53%). Fifty-six limbs (71%) underwent treatment for critical limb ischemia, including 42 (53%) with tissue loss. Eleven patients (15%) had previous failed bypasses. Preoperative ABIs were unobtainable for 23 patients, while the remaining 56 had a mean baseline ABI of 0.54 +/- 0.28. There was one periprocedural mortality. Five patients (6.3%) had periprocedural complications. Mean increase in ABI postprocedure was 0.49 +/- 0.35. Follow-up was available for 74 limbs at a mean of 10.7 months (range, 1-35). There were 18 mortalities (24.3%) during the follow-up period. No patient required a major amputation during this follow-up period. Twenty-one limbs (26.6%) experienced restenosis and nine limbs (11.4%) experienced occlusion. Twenty-nine limbs underwent reintervention during the follow-up time, including nine which underwent multiple reinterventions. Primary, assisted-primary, and secondary patency rates at 12 and 24 months were 52.2%, 88.4%, 92.6% and 27.5%, 74.2%, and 88.9%, respectively. Predictors of restenosis/occlusion included hypercholesterolemia, the presence of a popliteal artery stent, and patients who were current or former smokers. Endovascular

  7. A look into the endovascular crystal ball

    DEFF Research Database (Denmark)

    Schroeder, Torben Veith

    2009-01-01

    This paper summarizes the highlights of the 15th International Workshop of Endovascular Surgery, held in Ajaccio in June 2008. This is an annual event that attracts leading endovascular therapists from both sides of the Atlantic Ocean as well as a contingency from down-under. The layout of this m...

  8. Role of endovascular treatment in vascular injuries

    International Nuclear Information System (INIS)

    Tahir, M.M.; Haq, T.U.

    2012-01-01

    Objective: To evaluate retrospectively the results, complications and follow-up of patients after endovascular treatment of vascular injuries. Methods: Fifty transcatheter embolisation procedures (TCE) were performed in 46 patients between 1999 and 2008 at the Aga Khan University Hospital, Karachi. Injuries in 14 (30.4%) patients were due to road traffic accident; iatrogenic in 13 (28%); accidental in 6 (13%). Firearms, bomb blasts and earthquake contributed to injuries in 8(17%), 4(8.8%) and 1(2.2%) patients respectively. All patients underwent angiography and had evidence of either active haemorrhage, pseudo-aneurysm, abnormal vascularity or arteriovenous fistula. Follow-up ranged from 1 day to 6 years with mean of 10.5 months. Medical record files, lab results and imaging reports were utilised for the study. Procedure was declared as technically successful when there was cessation of extravasation, occlusion of fistula or exclusion of pseudo-aneurysm in the post-embolisation angiograms. Treatment was deemed clinically successful if there was resolution of the indication for which the procedure was done. Results: Transcatheter embolisation was technically successful in occluding vascular lesions in all 46 (100%) patients. Lesions recurred in 4 (9%) patients who underwent initially successful TCE. These patients were treated effectively with repeated TCE. Three patients died during the same hospital stay and 3 patients died after being discharged from the hospital. All these patients were treated successfully with TCE and had factors other then TCE contributing to their mortality. Conclusion: Transcatheter embolisation for vascular injuries was found to be a satisfactory procedure, with low morbidity and mortality rates. (author)

  9. Neonatal Intracranial Aneurysm Rupture Treated by Endovascular Management: A Case Report

    Directory of Open Access Journals (Sweden)

    Yi-Pei Tai

    2010-08-01

    Full Text Available Pediatric intracranial aneurysm rupture is rare, and is traditionally managed by surgical clipping. To the best of our knowledge, endovascular embolization of aneurysms in neonates has not previously been reported in Taiwan. We report a 9-day-old boy with intracranial aneurysms who underwent endovascular embolization, representing the youngest reported case in Taiwan. The 9-day-old boy presented with non-specific symptoms of irritable crying, seizure and respiratory distress. Computed tomography disclosed intraventricular hemorrhage, subarachnoid hemorrhage and focal intracranial hemorrhage around the right cerebellum. Subsequent computed tomographic angiography showed two sequential fusiform aneurysms, measuring 3 mm, located in the right side posterior inferior cerebellar artery (PICA. The patient underwent endovascular embolization because of the high risk of aneurysm re-rupture and the impossibility of surgical clipping due to the fusiform nature of the aneurysms. A postembolization angiogram revealed complete obliteration of the right distal PICA and proximal aneurysm. The distal PICA aneurysm was revascularized from the collateral circulation, but demonstrated a slow and delayed filling pattern. The patient's condition remained stable over the following week, and he was discharged without anticonvulsant therapy. No significant developmental delay was noted at follow-up at when he was 3 months old. This case emphasizes the need for clinical practitioners to consider a diagnosis of intracranial hemorrhage in neonates with seizure and increased intracranial pressure. Neonatal intracranial aneurysms can be treated safely by endovascular treatment.

  10. The impact of hybrid neurosurgeons on the outcomes of endovascular coiling for unruptured cerebral aneurysms

    Science.gov (United States)

    Bekelis, Kimon; Gottlieb, Dan; Labropoulos, Nicos; Su, Yin; Tzoumakaris, Stavropoula; Jabbour, Pasqual; MacKenzie, Todd A.

    2017-01-01

    Background The impact of combined practices on the outcomes of unruptured cerebral aneurysm coiling remains an issue of debate. We investigated the association of combined open and endovascular expertise with the outcomes of unruptured cerebral aneurysm coiling. Methods We performed a cohort study of 100% of Medicare fee-for-service claims data for elderly patients who underwent endovascular coiling for unruptured cerebral aneurysms from 2007 to 2012. In order to control for confounding we used propensity score conditioning, with mixed effects to account for clustering at the HRR level. Results During the study period, there were 11,716 patients, who underwent endovascular coiling for unruptured cerebral aneurysms, and met the inclusion criteria. Of these, 1,186 (10.1%) underwent treatment by hybrid neurosurgeons, and 10,530 (89.9%) by proceduralists who performed only endovascular coiling. Multivariable regression analysis with propensity score adjustment demonstrated lack of association of combined practice with 1-year postoperative mortality (OR, 0.84; 95% CI, 0.58–1.23), discharge to rehabilitation (OR, 1.0; 95% CI, 0.66–1.51), 30-day readmission rate (OR, 1.07; 95% CI, 0.83–1.38) and length of stay (LOS) (adjusted difference, 0.41; 95% CI, −0.26 to 1.09). Higher procedural volume was independently associated with improved outcomes. Conclusions In a cohort of Medicare patients, we did not demonstrate a difference in mortality, discharge to rehabilitation, readmission rate, and LOS between hybrid neurosurgeons, and proceduralists only performing endovascular coiling. Funding Supported by grants from the National Institute on Aging (PO1- AG19783), the National Institutes of Health Common Fund (U01-AG046830), and the National Center for Advancing Translational Sciences (NCATS) of the NIH (Dartmouth Clinical and Translational Science Institute-UL1TR001086). The funders had no role in the design or execution of the study. PMID:26918479

  11. Percutaneous Endovascular Radiofrequency Ablation for Malignant Portal Obstruction: An Initial Clinical Experience

    International Nuclear Information System (INIS)

    Wu, Tian-Tian; Li, Hu-Cheng; Zheng, Fang; Ao, Guo-Kun; Lin, Hu; Li, Wei-Min

    2016-01-01

    PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portal stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.

  12. Percutaneous Endovascular Radiofrequency Ablation for Malignant Portal Obstruction: An Initial Clinical Experience

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tian-Tian, E-mail: matthewwu1979@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China); Li, Hu-Cheng, E-mail: hucheng-li-surgery@126.com [The 307th Hospital of PLA, General Surgery Department (China); Zheng, Fang, E-mail: fang-zheng-surgery@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China); Ao, Guo-Kun, E-mail: guokun-ao-radiology@126.com; Lin, Hu, E-mail: hu-lin-radiology@126.com [The 309th Hospital of PLA, Radiology Department (China); Li, Wei-Min, E-mail: weimin-li-surgery@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China)

    2016-07-15

    PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portal stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.

  13. Physical aspects of endovascular brachytherapy

    International Nuclear Information System (INIS)

    Kirisits, C.

    2001-11-01

    Restenosis is severely limiting the outcome of vascular interventions. In several clinical trials endovascular brachytherapy has shown to reduce the restenosis rate. Local radiotherapy to the injured vessel wall is a promising new type of treatment in order to inhibit a complex wound healing process resulting in cell proliferation and re-obstruction of the treated vessel. Treatment planning has to be based on the dose distribution in the vicinity of the sources used. Source strength was determined in terms of air kerma rate for gamma nuclides (Iridium-192) and absorbed dose to water at reference distance of 2 mm for beta nuclides (Strontium-90/Yttrium-90, Phosphor-32), respectively. Radial dose profiles and the Reference Isodose Length (RIL) were determined using the EGSnrc code and GafChromic film. Good agreement was found between both methods. In order to treat the entire clinical target length, the (RIL) is an essential value during treatment planning. Examples are described for different levels of treatment planing including recommendations for optimal choice and positioning of the radioactive devices inside the artery. IVUS based treatment planning is illustrated with superposition of isodoses on cross-sectional images. A calculation model for radioactive stents is presented in order to determine dose volume histograms in a retrospective analysis. Radiation protection issues for endovascular brachytherapy are discussed in detail. Personal dose for the involved personnel is estimated based on calculations and measurements. Beta ray dosimetry is performed with suitable detectors. In order to estimate the exposure to the patient the dose to organs at risk is calculated and compared to the dose from angiography. There is an additional radiation exposure to patients and personnel caused by endovascular brachytherapy, but the values are much smaller than those caused by diagnostic angiography. (author)

  14. Total Percutaneous Aortic Repair: Midterm Outcomes

    International Nuclear Information System (INIS)

    Bent, Clare L.; Fotiadis, Nikolas; Renfrew, Ian; Walsh, Michael; Brohi, Karim; Kyriakides, Constantinos; Matson, Matthew

    2009-01-01

    The purpose of this study was to examine the immediate and midterm outcomes of percutaneous endovascular repair of thoracic and abdominal aortic pathology. Between December 2003 and June 2005, 21 patients (mean age: 60.4 ± 17.1 years; 15 males, 6 females) underwent endovascular stent-graft insertion for thoracic (n = 13) or abdominal aortic (n = 8) pathology. Preprocedural computed tomographic angiography (CTA) was performed to assess the suitability of aorto-iliac and common femoral artery (CFA) anatomy, including the degree of CFA calcification, for total percutaneous aortic stent-graft repair. Percutaneous access was used for the introduction of 18- to 26-Fr delivery devices. A 'preclose' closure technique using two Perclose suture devices (Perclose A-T; Abbott Vascular) was used in all cases. Data were prospectively collected. Each CFA puncture site was assessed via clinical examination and CTA at 1, 6, and 12 months, followed by annual review thereafter. Minimum follow-up was 36 months. Outcome measures evaluated were rates of technical success, conversion to open surgical repair, complications, and late incidence of arterial stenosis at the site of Perclose suture deployment. A total of 58 Perclose devices were used to close 29 femoral arteriotomies. Outer diameters of stent-graft delivery devices used were 18 Fr (n = 5), 20 Fr (n = 3), 22 Fr (n = 4), 24 Fr (n = 15), and 26 Fr (n = 2). Percutaneous closure was successful in 96.6% (28/29) of arteriotomies. Conversion to surgical repair was required at one access site (3.4%). Mean follow-up was 50 ± 8 months. No late complications were observed. By CT criteria, no patient developed a >50% reduction in CFA caliber at the site of Perclose deployment during the study period. In conclusion, percutaneous aortic stent-graft insertion can be safely performed, with a low risk of both immediate and midterm access-related complications.

  15. Fenestrated endovascular aortic aneurysm repair using physician-modified endovascular grafts versus company-manufactured devices.

    Science.gov (United States)

    Dossabhoy, Shernaz S; Simons, Jessica P; Flahive, Julie M; Aiello, Francesco A; Sheth, Parth; Arous, Edward J; Messina, Louis M; Schanzer, Andres

    2017-12-07

    Fenestrated endografts are customized, patient-specific endovascular devices with potential to reduce morbidity and mortality of complex aortic aneurysm repair. With approval from the U.S. Food and Drug Administration, our center began performing fenestrated endovascular aneurysm repair through a physician-sponsored investigational device exemption (IDE #G130210), using both physician-modified endografts (PMEGs) and company-manufactured devices (CMDs). Because these techniques are associated with specific advantages and disadvantages, we sought to investigate differences in outcomes between PMEG and CMD cases. A single-institution retrospective review of all fenestrated endovascular aneurysm repairs was performed. The cohort was analyzed by device type (PMEG or CMD) after matching of cases on the basis of (1) number of target vessels intended for treatment, (2) extent of aneurysm, (3) aneurysm diameter, (4) device configuration, and (5) date of operation. Outcomes of ruptures, common iliac artery aneurysms, and aortic arch aneurysms were excluded. Demographics, operative details, perioperative complications, length of stay, and reinterventions were compared. For patients with >1 year of follow-up time, survival, type I or type III endoleak rate, target artery patency, and reintervention rate were estimated using the Kaplan-Meier method. Between November 30, 2010, and July 30, 2016, 82 patients were identified and matched. The cohort included 41 PMEG and 41 CMD patients who underwent repair of 38 juxtarenal (PMEG, 17; CMD, 21; P = .38), 14 pararenal (PMEG, 6; CMD, 8; P = .56), and 30 thoracoabdominal type I to type IV (PMEG, 18; CMD, 12; P = .17) aneurysms. There were significant differences in presentation requiring urgent aneurysm repair (PMEG, 9; CMD, 0; P = .002), total fluoroscopy time (PMEG, 76 minutes; CMD, 61 minutes; P = .02), volume of contrast material used (PMEG, 88 mL; CMD, 70 mL; P = .02), in-operating room to out-of-operating room time

  16. Management and outcome of cardiac and endovascular cystic echinococcosis.

    Directory of Open Access Journals (Sweden)

    Marta Díaz-Menéndez

    2012-01-01

    Full Text Available BACKGROUND: Cystic echinococcosis (CE can affect the heart and the vena cava but few cases are reported. METHODS: A retrospective case series of 11 patients with cardiac and/or endovascular CE, followed-up over a period of 15 years (1995-2009 is reported. RESULTS: Main clinical manifestations included thoracic pain or dyspnea, although 2 patients were asymptomatic. Cysts were located mostly in the right atrium and inferior vena cava. Nine patients were previously diagnosed with disseminated CE. Echocardiography was the diagnostic method of choice, although serology, electrocardiogram, chest X-ray, computed tomography/magnetic resonance imaging and histology aided with diagnosis and follow-up. Nine patients underwent cardiac surgery and nine received long-term antiparasitic treatment for a median duration of 25 months (range 4-93 months. One patient died intra-operatively due to cyst rupture and endovascular dissemination. Two patients died 10 and 14 years after diagnosis, due to pulmonary embolism (PE and cardiac failure, respectively. One patient was lost to follow-up. Patients who had cardiac involvement exclusively did not have complications after surgery and were considered cured. There was only one recurrence requiring a second operation. Patients with vena cava involvement developed PEs and presented multiple complications. CONCLUSIONS: Cardiovascular CE is associated with a high risk of potentially lethal complications. Clinical manifestations and complications vary according to cyst location. Isolated cardiac CE may be cured after surgery, while endovascular extracardiac involvement is associated with severe chronic complications. CE should be included in the differential diagnosis of cardiovascular disease in patients from endemic areas.

  17. Vascular training and endovascular practice in Europe

    DEFF Research Database (Denmark)

    Liapis, C.D.; Avgerinos, E.D.; Sillesen, H.

    2009-01-01

    specialties was distributed to a VS educator within 14 European countries. European Vascular and Endovascular Monitor (EVEM) data also were processed to correlate endovascular practice with training models. RESULTS: Fourteen questionnaires were gathered. Vascular training in Europe appears in 3 models: 1....... Mono-specialty (independence): 7 countries, 2. Subspecialty: 5 countries, 3. An existing specialty within general surgery: 2 countries. Independent compared to non-independent certification shortens overall training length (5.9 vs 7.9 years, p=0.006), while increasing overall training devoted......% respectively. Countries with independent vascular certification, despite their lower average endovascular index (procedures per 100,000 population), reported a higher growth rate of aortic endovascular procedures (VS independent 132% vs VS non-independent 87%), within a four-year period (2003-2007). Peripheral...

  18. Acute vasculitis after endovascular brachytherapy

    International Nuclear Information System (INIS)

    Fajardo L-G, Luis F.; Prionas, Stavros D.; Kaluza, Grzegorz L.; Raizner, Albert E.

    2002-01-01

    Purpose: Angioplasty effectively relieves coronary artery stenosis but is often followed by restenosis. Endovascular radiation (β or γ) at the time of angioplasty prevents restenosis in a large proportion of vessels in swine (short term) and humans (short and long term). Little information is available about the effects of this radiation exposure beyond the wall of the coronary arteries. Methods and Materials: Samples were obtained from 76 minipigs in the course of several experiments designed to evaluate endovascular brachytherapy: 76 of 114 coronary arteries and 6 of 12 iliac arteries were exposed to endovascular radiation from 32 P sources (35 Gy at 0.5 mm from the intima). Two-thirds of the vessels had angioplasty or stenting. The vessels were systematically examined either at 28 days or at 6 months after radiation. Results: We found an unexpected lesion: acute necrotizing vasculitis in arterioles located ≤2.05 mm from the target artery. It was characterized by fibrinoid necrosis of the wall, often associated with lymphocytic exudates or thrombosis. Based on the review of perpendicular sections of tissue samples, the arterioles had received between 6 and 40 Gy. This arteriolar vasculitis occurred at 28 days in samples from 51% of irradiated coronary arteries and 100% of irradiated iliac arteries. By 6 months, the incidence of acute vasculitis decreased to 24% around the coronary arteries. However, at that time, healing vasculitis was evident, often with luminal narrowing, in 46% of samples. Vasculitis was not seen in any of 44 samples from unirradiated vessels (0%) and had no relation to angioplasty, stenting, or their sequelae. This radiation-associated vasculitis in the swine resembles the localized lymphocytic vasculitis that we have reported in tissues of humans exposed to external radiation. On the other hand, it is quite different from the various types of systemic vasculitis that occur in nonirradiated humans. Conclusion: Endoarterial brachytherapy

  19. Endovascular Management of Acute Limb Ischemia.

    LENUS (Irish Health Repository)

    Hynes, Brian G

    2011-09-14

    Despite major advances in pharmacologic and endovascular therapies, acute limb ischemia (ALI) continues to result in significant morbidity and mortality. The incidence of ALI may be as high as 13-17 cases per 100,000 people per year, with mortality rates approaching 18% in some series. This review will address the contemporary endovascular management of ALI encompassing pharmacologic and percutaneous interventional treatment strategies.

  20. Outcomes of fenestrated and branched endovascular repair of complex abdominal and thoracoabdominal aortic aneurysms.

    Science.gov (United States)

    Schanzer, Andres; Simons, Jessica P; Flahive, Julie; Durgin, Jonathan; Aiello, Francesco A; Doucet, Danielle; Steppacher, Robert; Messina, Louis M

    2017-09-01

    More than 80% of infrarenal aortic aneurysms are treated by endovascular repair. However, adoption of fenestrated and branched endovascular repair for complex aortic aneurysms has been limited, despite high morbidity and mortality associated with open repair. There are few published reports of consecutive outcomes, inclusive of all fenestrated and branched endovascular repairs, starting from the inception of a complex aortic aneurysm program. Therefore, we examined a single center's consecutive experience of fenestrated and branched endovascular repair of complex aortic aneurysms. This is a single-center, prospective, observational cohort study evaluating 30-day and 1-year outcomes in all consecutive patients who underwent fenestrated and branched endovascular repair of complex aortic aneurysms (definition: requiring one or more fenestrations or branches). Data were collected prospectively through an Institutional Review Board-approved registry and a physician-sponsored investigational device exemption clinical trial (G130210). We performed 100 consecutive complex endovascular aortic aneurysm repairs (November 2010 to March 2016) using 58 (58%) commercially manufactured custom-made devices and 42 (42%) physician-modified devices to treat 4 (4%) common iliac, 42 (42%) juxtarenal, 18 (18%) pararenal, and 36 (36%) thoracoabdominal aneurysms (type I, n = 1; type II, n = 4; type III, n = 12; type IV, n = 18; arch, n = 1). The repairs included 309 fenestrations, branches, and scallops (average of 3.1 branch arteries/case). All patients had 30-day follow-up for 30-day event rates: three (3%) deaths; six (6%) target artery occlusions; five (5%) progressions to dialysis; eight (8%) access complications; one (1%) paraparesis; one (1%) bowel ischemia; and no instances of myocardial infarction, paralysis, or stroke. Of 10 type I or type III endoleaks, 8 resolved (7 with secondary intervention, 1 without intervention). Mean follow-up time was 563 days (interquartile range

  1. Endovascular management for significant iatrogenic portal vein bleeding.

    Science.gov (United States)

    Kim, Jong Woo; Shin, Ji Hoon; Park, Jonathan K; Yoon, Hyun-Ki; Ko, Gi-Young; Gwon, Dong Il; Kim, Jin Hyoung; Sung, Kyu-Bo

    2017-11-01

    Background Despite conservative treatment, hemorrhage from an intrahepatic branch of the portal vein can cause hemodynamic instability requiring urgent intervention. Purpose To retrospectively report the outcomes of hemodynamically significant portal vein bleeding after endovascular management. Material and Methods During a period of 15 years, four patients (2 men, 2 women; median age, 70.5 years) underwent angiography and embolization for iatrogenic portal vein bleeding. Causes of hemorrhage, angiographic findings, endovascular treatment, and complications were reported. Results Portal vein bleeding occurred after percutaneous liver biopsy (n = 2), percutaneous radiofrequency ablation (n = 1), and percutaneous cholecystostomy (n = 1). The median time interval between angiography and percutaneous procedure was 5 h (range, 4-240 h). Common hepatic angiograms including indirect mesenteric portograms showed active portal vein bleeding into the peritoneal cavity with (n = 1) or without (n = 2) an arterioportal (AP) fistula, and portal vein pseudoaneurysm alone with an AP fistula (n = 1). Successful transcatheter arterial embolization (n = 2) or percutaneous transhepatic portal vein embolization (n = 2) was performed. Embolic materials were n-butyl cyanoacrylate alone (n = 2) or in combination with gelatin sponge particles and coils (n = 2). There were no major treatment-related complications or patient mortality within 30 days. Conclusion Patients with symptomatic or life-threatening portal vein bleeding following liver-penetrating procedures can successfully be managed with embolization.

  2. Thoracic aortic aneurysms and dissections: endovascular treatment.

    Science.gov (United States)

    Baril, Donald T; Cho, Jae S; Chaer, Rabih A; Makaroun, Michel S

    2010-01-01

    The treatment of thoracic aortic disease has changed radically with the advances made in endovascular therapy since the concept of thoracic endovascular aortic repair was first described 15 years ago. Currently, there is a diverse array of endografts that are commercially available to treat the thoracic aorta. Multiple studies, including industry-sponsored and single-institution reports, have demonstrated excellent outcomes of thoracic endovascular aortic repair for the treatment of thoracic aortic aneurysms, with less reported perioperative morbidity and mortality in comparison with conventional open repair. Additionally, similar outcomes have been demonstrated for the treatment of type B dissections. However, the technology remains relatively novel, and larger studies with longer term outcomes are necessary to more fully evaluate the role of endovascular therapy for the treatment of thoracic aortic disease. This review examines the currently available thoracic endografts, preoperative planning for thoracic endovascular aortic repair, and outcomes of thoracic endovascular aortic repair for the treatment of both thoracic aortic aneurysms and type B aortic dissections. Mt Sinai J Med 77:256-269, 2010. (c) 2010 Mount Sinai School of Medicine.

  3. Suprarenal fixation barbs can induce renal artery occlusion in endovascular aortic aneurysm repair.

    Science.gov (United States)

    Subedi, Shree K; Lee, Andy M; Landis, Gregg S

    2010-01-01

    Renal artery occlusion following endovascular abdominal aortic aneurysm repair with suprarenal fixation is uncommon. We report one patient who was found to develop renal artery occlusion and parenchymal infarction 6 months after repair using an endovascular graft with suprarenal fixation. Our patient underwent emergent endovascular repair of a symptomatic 6 cm abdominal aortic aneurysm. The covered portion of the endograft was inadvertently deployed well below the renal artery orifices. At the completion of the procedure both renal arteries were confirmed to be patent. One month postoperatively, a computed tomographic (CT) scan showed exclusion of the aortic sac and normal enhancement of both kidneys. At 6 months, the patient was found to have elevated serum creatinine levels despite having no clinical symptoms. CT scanning revealed a nonenhancing left kidney, and angiography demonstrated an occlusion of the left renal artery. A barb welded to the bare metal stent appeared to be impinging on the renal artery. We believe that renal artery occlusion after endovascular repair can occur due to repetitive injury to the renal artery orifice from barbs welded to the bare metal stent. To our knowledge, this is the first reported case of renal artery occlusion caused by repetitive injury from transrenal fixation systems. Copyright 2010 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  4. Aneurysmal wall enhancement and perianeurysmal edema after endovascular treatment of unruptured cerebral aneurysms

    International Nuclear Information System (INIS)

    Su, I. Chang; Willinsky, Robert A.; Agid, Ronit; Fanning, Noel F.

    2014-01-01

    Perianeurysmal edema and aneurysm wall enhancement are previously described phenomenon after coil embolization attributed to inflammatory reaction. We aimed to demonstrate the prevalence and natural course of these phenomena in unruptured aneurysms after endovascular treatment and to identify factors that contributed to their development. We performed a retrospective analysis of consecutively treated unruptured aneurysms between January 2000 and December 2011. The presence and evolution of wall enhancement and perianeurysmal edema on MRI after endovascular treatment were analyzed. Variable factors were compared among aneurysms with and without edema. One hundred thirty-two unruptured aneurysms in 124 patients underwent endovascular treatment. Eighty-five (64.4 %) aneurysms had wall enhancement, and 9 (6.8 %) aneurysms had perianeurysmal brain edema. Wall enhancement tends to persist for years with two patterns identified. Larger aneurysms and brain-embedded aneurysms were significantly associated with wall enhancement. In all edema cases, the aneurysms were embedded within the brain and had wall enhancement. Progressive thickening of wall enhancement was significantly associated with edema. Edema can be symptomatic when in eloquent brain and stabilizes or resolves over the years. Our study demonstrates the prevalence and some appreciation of the natural history of aneurysmal wall enhancement and perianeurysmal brain edema following endovascular treatment of unruptured aneurysms. Aneurysmal wall enhancement is a common phenomenon while perianeurysmal edema is rare. These phenomena are likely related to the presence of inflammatory reaction near the aneurysmal wall. Both phenomena are usually asymptomatic and self-limited, and prophylactic treatment is not recommended. (orig.)

  5. [Microscopic investigation of vessel wall after endovascular catheter atherectomy].

    Science.gov (United States)

    Tsygankov, V N; Khovalkin, R G; Chekmareva, I A; Kalinin, D V; Filippova, E M

    2014-01-01

    Endovascular target catheter atherectomy (ETCA) - method of artery patency allowing to obtain occlusion substrate. Given the high destructive effect of atherectome's elements on tissue the objective was determination possibility of histological and electron microscopic investigation of this substrate after atherectomy. The research included 8 patients who underwent ETCA of legs arteries. It was observed substrate removal from broken stent in 1 case. 2 of 8 patients had diabetes. Obtained substrate was available for histological and electron microscopic investigation. Atherosclerosis was confirmed in all cases. It was not observed substrate significant morphological changes in patients with presence or absence of diabetes. Microscopic investigation of substrate from broken stent shows pronounced development of granulation tissue that was regarded as special form of reparative regeneration. Finding internal elastic membrane during microscopic investigation in some cases proves radical intervention. The authors consider that microscopic investigation of substrate after ETCA may be used for diagnosis verification, thorough analysis of morphological changes in lesion area and radicalism of atherectomy.

  6. Endovascular Treatment of Incoercible Epistaxis and Epidural Cerebral Hematoma

    Science.gov (United States)

    Bortoluzzi, M.; Pavia, M.

    2006-01-01

    Summary A young patient with a facial trauma after a road accident was admitted to our department with incoercible epistaxis. A CT scan showed a right pterional acute epidural hematoma (EDH). Angiography demonstrated multiple sources of bleeding of the right sphenopalatine arteries, cause of the epistaxis, and an intracranial leakage of the right middle meningeal artery, responsible for the EDH. The patient immediately underwent embolization of the right internal maxillary artery and right middle meningeal artery. The procedure stopped the epistaxis and no further enlargement of the EDH was observed, avoiding its surgical treatment. Endovascular surgery may be an effective procedure to stop the arterial meningeal bleeding sustaining acute EDH and may be a useful tool in the management of special cases of post traumatic EDH. PMID:20569576

  7. Early inflammatory response following elective abdominal aortic aneurysm repair: A comparison between endovascular procedure and conventional, open surgery

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2011-01-01

    Full Text Available Background/Aim. Abdominal aorta aneurysm (AAA represents a pathological enlargment of infrarenal portion of aorta for over 50% of its lumen. The only treatment of AAA is a surgical reconstruction of the affected segment. Until the late XX century, surgical reconstruction implied explicit, open repair (OR of AAA, which was accompanied by a significant morbidity and mortality of the treated patients. Development of endovascular repair of (EVAR AAA, especially in the last decade, offered another possibility of surgical reconstruction of AAA. The preliminary results of world studies show that complications of such a procedure, as well as morbidity and mortality of patients, are significantly lower than with OR of AAA. The aim of this paper was to present results of comparative clinical prospective study of early inflammatory response after reconstruction of AAA between endovascular and open, conventional surgical technique. Methods. A comparative clinical prospective study included 39 patients, electively operated on for AAA within the period of December 2008 - February 2010, divided into two groups. The group I counted 21 (54% of the patients, 58-87 years old (mean 74.3 years, who had been submited to EVAR by the use of excluder stent graft. The group II consisted of 18 (46% of the patients, 49-82 (mean 66.8 years, operated on using OR technique. All of the treated patients in both groups had AAA larager than 50 mm. The study did not include patients who have been treated as urgent cases, due to the rupture or with simptomatic AAA. Clinical, biochemical and inflamatory parameters in early postoperative period were analyzed, in direct postoperative course (number of leucocytes, thrombocytes, serum circulating levels of cytokine - interleukine (IL-2, IL-4, IL-6 and IL-10. Parameters were monitored on the zero, first, second, third and seventh postoperative days. The study was approved by the Ethics Commitee of the Military Medical Academy. Results

  8. DRAGON score predicts functional outcomes in acute ischemic stroke patients receiving both intravenous tissue plasminogen activator and endovascular therapy.

    Science.gov (United States)

    Wang, Arthur; Pednekar, Noorie; Lehrer, Rachel; Todo, Akira; Sahni, Ramandeep; Marks, Stephen; Stiefel, Michael F

    2017-01-01

    The DRAGON score, which includes clinical and computed tomographic (CT) scan parameters, predicts functional outcomes in ischemic stroke patients treated with intravenous tissue plasminogen activator (IV tPA). We assessed the utility of the DRAGON score in predicting functional outcome in stroke patients receiving both IV tPA and endovascular therapy. A retrospective chart review of patients treated at our institution from February 2009 to October 2015 was conducted. All patients with computed tomography angiography (CTA) proven large vessel occlusions (LVO) who underwent intravenous thrombolysis and endovascular therapy were included. Baseline DRAGON scores and modified Rankin Score (mRS) at the time of hospital discharge was calculated. Good outcome was defined as mRS ≤3. Fifty-eight patients with LVO of the anterior circulation were studied. The mean DRAGON score of patients on admission was 5.3 (range, 3-8). All patients received IV tPA and endovascular therapy. Multivariate analysis demonstrated that DRAGON scores ≥7 was associated with higher mRS ( P DRAGON scores ≤6. Patients with DRAGON scores of 7 and 8 on admission had a mortality rate of 3.8% and 40%, respectively. The DRAGON score can help predict better functional outcomes in ischemic stroke patients receiving both IV tPA and endovascular therapy. This data supports the use of the DRAGON score in selecting patients who could potentially benefit from more invasive therapies such as endovascular treatment. Larger prospective studies are warranted to further validate these results.

  9. Feasibility of Endovascular Radiation Therapy Using Holmium-166 Filled Balloon Catheter in a Swine Hemodialysis Fistula Model: Preliminary Results

    Energy Technology Data Exchange (ETDEWEB)

    Won, Jong Yun; Lee, Kwang Hun; Lee, Do Yun [Dept. of Radiology, Research Institute of Radiological Science, Yensei University College of Medicine, Seoul (Korea, Republic of); Kim, Myoung Soo [Dept. of Radiology, Yensei University College of Medicine, Seoul (Korea, Republic of); Kang, Byung Chul [Dept. of Radiology, Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of); Kim, Seung Jung [Dept. of Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of)

    2011-08-15

    To describe how to make a swine hemodialysis fistula model and report our initial experience to test the feasibility of endovascular radiation therapy with Holmium-166 filled balloon catheters. The surgical formation of arterio-venous fistula (AVF) was performed by end-to-side anastomosis of the bilateral jugular vein and carotid artery of 6 pigs. After 4 weeks, angiograms were taken and endovascular radiation was delivered to the venous side of AVF with Holmium-166 filled balloon catheters. Pigs were sacrificed 4 weeks after the radiation and AVFs were harvested for histological examination. All animals survived without any morbidity during the experimental periods. The formation of fistula on the sides of necks was successful in 11 of the 12 pigs (92%). One AVF failed from the small jugular vein. On angiograms, 4 of the 11 AVFs showed total occlusion or significant stenosis and therefore, endovascular radiation could not be performed. Of 7 eligible AVFs, five underwent successful endovascular radiation and two AVFs did not undergo radiation for the control. Upon histologic analysis, one non-radiated AVF showed total occlusion and others showed intimal thickening from the neointimal hyperplasia. Formation of the swine carotid artery-jugular vein hemodialysis fistula model was successful. Endovascular radiation using a Holmium-166 filled balloon catheter was safe and feasible.

  10. Endovascular control of haemorrhagic urological emergencies: an observational study

    Directory of Open Access Journals (Sweden)

    Thorpe Peter

    2006-09-01

    Full Text Available Abstract Background Transarterial embolisation (TAE is an effective method in control of haemorrhage irrespective of the nature of urological emergency. As the technique and technology have evolved, it is now possible to perform highly selective embolisation. The aim of this study was to critically appraise feasibility and efficacy of therapeutic TAE in control of haemorrhagic urological emergencies using selective and non-selective embolisation. Specifically, we aimed to assess the impact of timing of embolisation on the requirement of blood transfusion and long-term morphological and functional follow-up of embolised organs. Methods This is a single institutional observational study carried out between March 1992 and March 2006. Records of all patients who underwent selective and non-selective angioembolisation to control bleeding in urological emergencies were reviewed. Data on success rate, periprocedural complications, timing of embolisation, requirement of blood transfusion and the long-term morphological and functional outcomes of embolised organs was recorded. Results Fourteen patients underwent endovascular control of bleeding as a result of trauma, iatrogenic injury and spontaneous perinephric haemorrhage during a period of 14 years. All these patients would have required emergency open surgery without the option of embolisation procedure. The mean time between the first presentation and embolisation was 22 hours (range 30 minutes to 60 hours. Mean pre-embolisation transfusion requirement was 6.8 units (range 0–22 units. None of the patients with successful embolisation required post-procedural blood transfusion. Permanent haemostasis was achieved in all but one patient, who required emergency nephrectomy. There were no serious procedure related post-embolisation complications. Conclusion Endovascular control using transarterial angioembolisation is an effective method for managing haematuria or haemorrhage in urological emergencies

  11. Endovascular Procedures in Treatment of Infrapopliteal Arterial Occlusive Disease: Single Center Experience With 69 Infrapopliteal Procedures.

    Science.gov (United States)

    Janko, Pasternak J; Nebojsa, Budakov B; Andrej, Petres V

    2018-03-01

    Peripheral arterial occlusive disease (PAD) includes acute and chronic disorders of the blood supply as a result of obstruction of blood flow in the arteries of the limb. Treatment of PAD can be conservative, surgical and endovascular. Percutaneous transluminal angioplasty with or without stenting has become a recognized method, which is increasingly used in treatment of arterial occlusive disease. This study aimed to determine early results of endovascular treatment of critical limb ischemia (CLI) patients with infrapopliteal lesions. The study included 69 patients (46 men; mean age 65 years, range 38-84) with CLI (class 4 to 6 according to Rutherford). The primary study endpoints were absence of major amputation of the target limb at 6 months and occurance of local and systemic complications specifically related to use of endovascular treatment. Major amputation was avoided in 61 patients. Through 6 months, 6 patients underwent additional revascularization. One local complication (clinicaly significant dissection of popliteal artery) occurred, and it was resolved by stent implantation. There were no cases of systemic complications and death during the follow-up period. Rates of major amputation were 12.3% for diabetics versus 8.3% for non-diabetics. Our data showed that endovascular treatment of infrapopliteal disease is an effective and safe treatment in patients experiencing CLI, provides high limb preservation and low complication rates. Study outcomes support endovascular treatment as a primary option for patients experiencing CLI due to below the knee (BTK) occlusive disease. © 2018 The Author(s). This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  12. Predictors of Reintervention After Endovascular Repair of Isolated Iliac Artery Aneurysm

    International Nuclear Information System (INIS)

    Zayed, Hany A.; Attia, Rizwan; Modarai, Bijan; Clough, Rachel E.; Bell, Rachel E.; Carrell, Tom; Sabharwal, Tarun; Reidy, John; Taylor, Peter R.

    2011-01-01

    The objective of this study was to identify factors predicting the need for reintervention after endovascular repair of isolated iliac artery aneurysm (IIAA). We reviewed prospectively collected database records of all patients who underwent endovascular repair of IIAA between 1999 and 2008. Detailed assessment of the aneurysms was performed using computed tomography angiography (CTA). Follow-up protocol included CTA at 3 months. If this showed no complication, then annual duplex scan was arranged. Multivariate analysis and analysis of patient survival and freedom from reintervention were performed using Kaplan–Meier life tables. Forty IIAAs (median diameter 44 mm) in 38 patients were treated (all men; median age 75 years), and median follow-up was 27 months. Endovascular repair of IIAA was required in 14 of 40 aneurysms (35%). The rate of type I endoleak was significantly higher with proximal landing zone (PLZ) diameter >30 mm in the aorta or >24 mm in the common iliac artery or distal landing zone (DLZ) diameter >24 mm (P = 0.03, 0.03, and 0.0014, respectively). Reintervention rate (RR) increased significantly with increased diameter or decreased length of PLZ; increased DLZ diameter; and endovascular IIAA repair (P = 0.005, 0.005, 0.02, and 0.02 respectively); however, RR was not significantly affected by length of PLZ or DLZ. Freedom-from-reintervention was 97, 93, and 86% at 12, 24, and 108 months. There was no in-hospital or aneurysm-related mortality. Endovascular IIAA repair is a safe treatment option. Proper patient selection is essential to decrease the RR.

  13. A case of acute ischemic colitis after endovascular abdominal aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    Grigorios Voulalas

    2016-01-01

    Full Text Available Colonic ischemia is a recognized complication of either open or endovascular abdominal aortic aneurysm repair. The clinical difficulty in establishing the diagnosis, the severity of this complication and the patient's poor physiological status may lead to a fatal outcome. We presented a case of ischemic colitis in a patient with patent hypogastric arteries that occurred after an endovascular abdominal aortic aneurysm repair as well as a review of the available literature. The patient's preoperative, intraoperative and postoperative data were recorded. A thorough search through the Google data and Medline to review similar cases or any analyses that referred to ischemic colitis after endovascular abdominal aneurysm repair was conducted. A 76-year-old male was admitted to our department for an elective endovascular repair of an 8 cm in diameter abdominal aortic aneurysm. A Zenith bifurcation graft was implanted. The whole procedure was uneventful and the final angiogram showed an accurate deployment of the endograft without endoleaks and patency of both hypogastric arteries. During the 1st postoperative day, the patient developed symptoms of acute abdomen in combination with metabolic acidosis and oliguria. He underwent an exploratory laparotomy, which revealed necrosis of the sigmoid. A Hartmann's procedure was performed; the patient was transferred to the intensive care unit where he deceased after 24 h. Postoperative ischemic colitis has been described after open abdominal aneurysm repair. The description of this complication has been reported since the early phase of endovascular abdominal aneurysm repair development with a current incidence of 1.5%–3.0%. Possible mechanisms that may contribute to ischemic colitis in spite of the presence of patent hypogastric arteries include atheroembolization, shock, vasopressive drugs and inferior mesenteric artery occlusion.

  14. Clinical outcome after endovascular coil embolization in elderly patients with subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Johansson, M.; Cesarini, K.G.; Ronne-Engstroem, E.; Enblad, P.; Norbaeck, O.; Gal, G.; Tovi, M.; Solander, S.; Contant, C.F.

    2004-01-01

    Subarachnoid hemorrhage (SAH) is not an unusual disease in an elderly population. The clinical outcome has improved over time. It has been suggested that elderly SAH patients would benefit from endovascular aneurysm treatment. The aim of this study was to evaluate technical results and clinical outcome in a series of elderly SAH-patients treated with endovascular coil embolization. Sixty-two patients (≥ 65 years) presenting with aneurysmal SAH underwent early endovascular coil embolization at Uppsala University Hospital between September 1996 and December 2000. In all 62 cases included in the study, endovascular coil embolization was considered the first line of treatment. Admission variables, specific information on technical success, degree of occlusion and procedural complications, and outcome figures were recorded. Clinical grade on admission was Hunt and Hess (H and H) I-II in 39%, H and H III in 27% and H and H IV-V in 34% of the patients. The proportion of posterior circulation aneurysms was 24%. Coil embolization was successfully completed in 94%. The degree of occlusion of the treated aneurysm was complete occlusion in 56%, neck remnant in 21%, residual filling in 11%, other remnant in 5% and not treated in 6%. The rate of procedural complications was 11%. Outcome after 6 months was favorable in 41%, severe disability in 36% and poor in 22%. Favorable outcome was achieved in 57% of the H and H I-II patients, 47% of the H and H III patients and 17% of the H and H IV-V patients. Endovascular aneurysm treatment can be performed in elderly patients with SAH with a high level of technical success, acceptable aneurysm occlusion results, an acceptable rate of procedural complications and fair outcome results. (orig.)

  15. Thromboembolic Risk of Endovascular Intervention for Lower Extremity Deep Venous Thrombosis.

    Science.gov (United States)

    Lindsey, Philip; Echeverria, Angela; Poi, Mun J; Matos, Jesus; Bechara, Carlos F; Cheung, Mathew; Lin, Peter H

    2018-05-01

    This study evaluated the risk of thromboembolism during endovascular interventions in patients with symptomatic lower extremity deep vein thrombosis (DVT) METHODS: Clinical records of all patients who underwent endovascular interventions for symptomatic lower extremity DVT from 2001 to 2017 were retrospectively analyzed using a prospectively maintained database. Only patients who received an inferior vena cava (IVC) filter were included in the analysis. Trapped intrafilter thrombus was assessed for procedure-related thromboembolism. Clinical outcomes of thrombus management and thromboembolism risk were analyzed. A total 172 patients (mean age 57.4 years, 98 females) who underwent 174 endovascular DVT interventions were included in the analysis. Treatment strategies included thrombolytic therapy (64%), mechanical thrombectomy (n = 86%), pharmacomechanical thrombolysis (51%), balloon angioplasty (98%), and stent placement (28%). Thrombectomy device used included AngioJet (56%), Trellis (19%), and Aspire (11%). Trapped IVC filter thrombus was identified in 58 patients (38%) based on the IVC venogram. No patient developed clinically evident pulmonary embolism (PE). IVC filter retrieval was performed in 98 patients (56%, mean 11.8 months after implantation). Multivariate analysis showed that iliac vein occlusion (P = 0.04) was predictive for procedure-related thromboembolism. Iliac vein thrombotic occlusion is associated with an increased thromboembolic risk in DVT intervention. Retrievable IVC filter should be considered when performing percutaneous thrombectomy in patients with iliac venous occlusion to prevent PE. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Percutaneous Transabdominal Approach for the Treatment of Endoleaks after Endovascular Repair of Infrarenal Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sun Young; Lee, Do Yun; Lee, Kwang Hun [Severance Hospital, University of Yonsei, Seoul (Korea, Republic of); Won, Jong Yun [Gangnam Severance Hospital, University of Yonsei, Seoul (Korea, Republic of); Choi, Dong Hoon; Shim, Won Heum [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2010-02-15

    The purpose of this study was to evaluate the technical feasibility and clinical efficacy of percutaneous transabdominal treatment of endoleaks after endovascular aneurysm repair. Between 2000 and 2007, six patients with type I (n = 4) or II (n = 2) endoleaks were treated by the percutaneous transabdominal approach using embolization with N-butyl cyanoacrylate with or without coils. Five patients underwent a single session and one patient had two sessions of embolization. The median time between aneurysm repair and endoleak treatment was 25.5 months (range: 0-84 months). Follow-up CT images were evaluated for changes in the size and shape of the aneurysm sac and presence or resolution of endoleaks. The median follow-up after endoleak treatment was 16.4 months (range: 0-37 months). Technical success was achieved in all six patients. Clinical success was achieved in four patients with complete resolution of the endoleak confirmed by follow-up CT. Clinical failure was observed in two patients. One eventually underwent surgical conversion, and the other was lost to follow-up. There were no procedure-related complications. The percutaneous transabdominal approach for the treatment of type I or II endoleaks, after endovascular aneurysm repair, is an alternative method when conventional endovascular methods have failed.

  17. Evaluation of diffusion-perfusion mismatch for determining indication for emergency endovascular revascularization

    International Nuclear Information System (INIS)

    Masuda, Atsushi; Miki, Takanori; Matsumoto, Hiroaki

    2010-01-01

    We evaluated the usefulness of assessing by diffusion-perfusion mismatch (D/P mismatch) whether there is adaptation of neuroendovascular revascularization for acute ischemic stroke out of intravenous tissue plasminogen activator (IV t-PA). We retrospectively analyzed 24 patients who underwent D/P mismatch and endovascular treatment between October 2005 and September 2008. This investigation included stroke patients with a National Institutes of Health Stroke Scale (NIHSS) score less than 4. Sixteen acute ischemic stroke patients had an NIHSS score greater than 5. Eight patients (50%) had a favorable neurological outcome (modified Rankin Scale 0 to 2). Eight acute ischemic stroke patients had an NIHSS score equal to or less than 4. Four patients who underwent emergency endovascular treatment on admission had a favorable neurological outcome, but 3 patients treated for progressive stroke after admission all had a poor prognosis. Evaluating D/P mismatch was useful for determining the adaptation of emergency neuroendovascular revascularization for acute ischemic stroke out of IV t-PA. Acute ischemic stroke patients with an NIHSS score equal to or less than 4 and diffusion/perfusion mismatch need careful observation to enable endovascular treatment immediately after progressive stroke. (author)

  18. Evaluation of the efficacy and safety of endovascular management for transplant renal artery stenosis

    Directory of Open Access Journals (Sweden)

    Leonardo G.M. Valle

    Full Text Available OBJECTIVES: To evaluate the safety and efficacy of endovascular intervention with angioplasty and stent placement in patients with transplant renal artery stenosis. METHODS: All patients diagnosed with transplant renal artery stenosis and graft dysfunction or resistant systemic hypertension who underwent endovascular treatment with stenting from February 2011 to April 2016 were included in this study. The primary endpoint was clinical success, and the secondary endpoints were technical success, complication rate and stent patency. RESULTS: Twenty-four patients with transplant renal artery stenosis underwent endovascular treatment, and three of them required reinterventions, resulting in a total of 27 procedures. The clinical success rate was 100%. All graft dysfunction patients showed decreased serum creatinine levels and improved estimated glomerular filtration rates and creatinine levels. Patients with high blood pressure also showed improved control of systemic blood pressure and decreased use of antihypertensive drugs. The technical success rate of the procedure was 97%. Primary patency and assisted primary patency rates at one year were 90.5% and 100%, respectively. The mean follow-up time of patients was 794.04 days after angioplasty. CONCLUSION: Angioplasty with stent placement for the treatment of transplant renal artery stenosis is a safe and effective technique with good results in both the short and long term.

  19. Endovascular Treatment of a Gastroduodenal Artery Pseudoaneurysm Rupture after a Car Accident

    Directory of Open Access Journals (Sweden)

    Sofia Dutra

    2017-09-01

    Full Text Available The authors present a case of a 39-year-old man with alcoholic chronic pancreatitis that was admitted in the emergency department after a car accident, complaining of abdominal pain and looking pale. The patient was hemodinamically unstable, requiring blood transfusions. He underwent computed tomography angiogram of the abdomen and pelvis, showing a pseudoaneurysm of the gastroduodenal artery and a hemoperitoneum. He was referred to our interventional radiology unit and submitted to endovascular treatment, consisting of ‘backdoor’ and ‘frontdoor’ embolization of the gastroduodenal artery and pseudoaneurysm neck with coils, with total exclusion in control angiography. With this case description we intend to highlight the rarity of the pseudoaneurysm rupture of the gastroduodenal artery and to emphasize the importance of an interventional radiology response that had a fundamental role in the endovascular treatment, in an emergency context.

  20. Perioperative complications in endovascular neurosurgery: Anesthesiologist's perspective

    Science.gov (United States)

    Sharma, Megha U.; Ganjoo, Pragati; Singh, Daljit; Tandon, Monica S.; Agarwal, Jyotsna; Sharma, Durga P.; Jagetia, Anita

    2017-01-01

    Background: Endovascular neurosurgery is known to be associated with potentially serious perioperative complications that can impact the course and outcome of anesthesia. We present here our institutional experience in the anesthetic management of various endovascular neurosurgical procedures and their related complications over a 10-year period. Methods: Data was obtained in 240 patients pertaining to their preoperative status, details of anesthesia and surgery, perioperative course and surgery-related complications. Information regarding hemodynamic alterations, temperature variability, fluid-electrolyte imbalance, coagulation abnormalities and alterations in the anesthesia course was specifically noted. Results: Among the important complications observed were aneurysm rupture (2.5%), vasospasm (6.67%), thromboembolism (4.16%), contrast reactions, hemodynamic alterations, electrolyte abnormalities, hypothermia, delayed emergence from anesthesia, groin hematomas and early postoperative mortality (5.14%). Conclusion: Awareness of the unique challenges of endovascular neurosurgery and prompt and appropriate management of the associated complications by an experienced neuroanesthesiologist is vital to the outcome of these procedures. PMID:28413524

  1. Source of errors and accuracy of a two-dimensional/three-dimensional fusion road map for endovascular aneurysm repair of abdominal aortic aneurysm.

    Science.gov (United States)

    Kauffmann, Claude; Douane, Frédéric; Therasse, Eric; Lessard, Simon; Elkouri, Stephane; Gilbert, Patrick; Beaudoin, Nathalie; Pfister, Marcus; Blair, Jean François; Soulez, Gilles

    2015-04-01

    To evaluate the accuracy and source of errors using a two-dimensional (2D)/three-dimensional (3D) fusion road map for endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm. A rigid 2D/3D road map was tested in 16 patients undergoing EVAR. After 3D/3D manual registration of preoperative multidetector computed tomography (CT) and cone beam CT, abdominal aortic aneurysm outlines were overlaid on live fluoroscopy/digital subtraction angiography (DSA). Patient motion was evaluated using bone landmarks. The misregistration of renal and internal iliac arteries were estimated by 3 readers along head-feet and right-left coordinates (z-axis and x-axis, respectively) before and after bone and DSA corrections centered on the lowest renal artery. Iliac deformation was evaluated by comparing centerlines before and during intervention. A score of clinical added value was estimated as high (z-axis 5 mm). Interobserver reproducibility was calculated by the intraclass correlation coefficient. The lowest renal artery misregistration was estimated at x-axis = 10.6 mm ± 11.1 and z-axis = 7.4 mm ± 5.3 before correction and at x-axis = 3.5 mm ± 2.5 and z-axis = 4.6 mm ± 3.7 after bone correction (P = .08), and at 0 after DSA correction (P artery was estimated at x-axis = 2.4 mm ± 2.0 and z-axis = 2.2 mm ± 2.0. Score of clinical added value was low (n = 11), good (n= 0), and high (n= 5) before correction and low (n = 5), good (n = 4), and high (n = 7) after bone correction. Interobserver intraclass correlation coefficient for misregistration measurements was estimated at 0.99. Patient motion before stent graft delivery was estimated at x-axis = 8 mm ± 5.8 and z-axis = 3.0 mm ± 2.7. The internal iliac artery misregistration measurements were estimated at x-axis = 6.1 mm ± 3.5 and z-axis = 5.6 mm ± 4.0, and iliac centerline deformation was estimated at 38.3 mm ± 15.6. Rigid registration is feasible and fairly accurate. Only a partial reduction of vascular

  2. Endovascular Neurosurgery: Personal Experience and Future Perspectives.

    Science.gov (United States)

    Raymond, Jean

    2016-09-01

    From Luessenhop's early clinical experience until the present day, experimental methods have been introduced to make progress in endovascular neurosurgery. A personal historical narrative, spanning the 1980s to 2010s, with a review of past opportunities, current problems, and future perspectives. Although the technology has significantly improved, our clinical culture remains a barrier to methodologically sound and safe innovative care and progress. We must learn how to safely practice endovascular neurosurgery in the presence of uncertainty and verify patient outcomes in real time. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Preoperative Evaluation and Endovascular Procedure of Intraoperative Aneurysm Rupture During Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Zha, Bin-Shan, E-mail: binszha2013@163.com; Zhu, Hua-Gang, E-mail: huagzhu@yeah.net; Ye, Yu-Sheng, E-mail: yeyusheng@aliyun.com; Li, Yong-Sheng, E-mail: 872868848@qq.com; Zhang, Zhi-Gong, E-mail: zzgedward@sina.com; Xie, Wen-Tao, E-mail: 345344347@qq.com [The First Affiliated Hospital of Anhui Medical University, Department of Vascular Surgery (China)

    2017-03-15

    Thoracic aortic aneurysms are now routinely repaired with endovascular repair if anatomically feasible because of advantages in safety and recovery. However, intraoperative aneurysm rupture is a severe complication which may have an adverse effect on the outcome of treatment. Comprehensive preoperative assessment and considerate treatment are keys to success of endovascular aneurysm repair, especially during unexpected circumstances. Few cases have reported on intraoperative aortic rupture, which were successfully managed by endovascular treatment. Here, we present a rare case of an intraoperative aneurysm rupture during endovascular repair of thoracic aortic aneurysm with narrow neck and angulated aorta arch (coarctation-associated aneurysm), which was successfully treated using double access route approach and iliac limbs of infrarenal devices.Level of EvidenceLevel 5.

  4. Reverse extra-anatomic aortic arch debranching procedure allowing thoracic endovascular aortic repair of a chronic ascending aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Ludovic Canaud, MD, PhD

    2018-06-01

    Full Text Available A 79-year-old woman was admitted with a large chronic dissecting ascending aortic aneurysm starting 5 mm distal to the ostia of the left coronary artery and ending immediately proximal to the innominate artery. A reverse extra-anatomic aortic arch debranching procedure was performed. During the same operative time, through a transapical approach, a thoracic stent graft was deployed with the proximal landing zone just distal to the coronary ostia and the distal landing zone excluding the origin of the left common carotid artery. The postoperative course was uneventful. Computed tomography at 12 months documented patent extra-anatomic aortic arch debranching and no evidence of endoleak. Keywords: Ascending aorta, Thoracic aorta, Aortic dissection, Stent graft

  5. Emergent Endovascular Management of Acute Arterial Bleeding ...

    African Journals Online (AJOL)

    multiruka1

    little attention has been paid to the novel endovascular options available .... Fig 1b. Fig 1c. Figure 1a: Mass at gastric fundus enhanced in post contrast CT abdomen. ... 1c: Left gastric artery super selectively coiled to occlusion. Fig 2a. Fig 2b.

  6. Carotid artery revascularization : Surgical and endovascular developments

    NARCIS (Netherlands)

    Borst, G.J. de

    2007-01-01

    Carotid artery revascularization. Surgical and endovascular developments. Stroke is among the most disabling chronic diseases and the third major cause of death in the Western world. In the Netherlands around 12 per 1000 inhabitants suffers a stroke, and in 2005 over 10.000 people died as a result

  7. Bronchoscopic guidance of endovascular stenting limits airway compression.

    Science.gov (United States)

    Ebrahim, Mohammad; Hagood, James; Moore, John; El-Said, Howaida

    2015-04-01

    Bronchial compression as a result of pulmonary artery and aortic arch stenting may cause significant respiratory distress. We set out to limit airway narrowing by endovascular stenting, by using simultaneous flexible bronchoscopy and graduated balloon stent dilatation, or balloon angioplasty to determine maximum safe stent diameter. Between August 2010 and August 2013, patients with suspected airway compression by adjacent vascular structures, underwent CT or a 3D rotational angiogram to evaluate the relationship between the airway and the blood vessels. If these studies showed close proximity of the stenosed vessel and the airway, simultaneous bronchoscopy and graduated stent re-dilation or graduated balloon angioplasty were performed. Five simultaneous bronchoscopy and interventional catheterization procedures were performed in four patients. Median age/weight was 33 (range 9-49) months and 14 (range 7.6-24) kg, respectively. Three had hypoplastic left heart syndrome, and one had coarctation of the aorta (CoA). All had confirmed or suspected left main stem bronchial compression. In three procedures, serial balloon dilatation of a previously placed stent in the CoA was performed and bronchoscopy was used to determine the safest largest diameter. In the other two procedures, balloon testing with simultaneous bronchoscopy was performed to determine the stent size that would limit compression of the adjacent airway. In all cases, simultaneous bronchoscopy allowed selection of an ideal caliber of the stent that optimized vessel diameter while minimizing compression of the adjacent airway. In cases at risk for airway compromise, flexible bronchoscopy is a useful tool to guide endovascular stenting. Maximum safe stent diameter can be determined without risking catastrophic airway compression. © 2014 Wiley Periodicals, Inc.

  8. Endovascular Therapeutic Approaches for Acute Superior Mesenteric Artery Occlusion

    International Nuclear Information System (INIS)

    Acosta, S.; Sonesson, B.; Resch, T.

    2009-01-01

    The purpose of this study was to characterize the outcome of attempted endovascular intervention in patients with acute embolic or thrombotic superior mesenteric artery (SMA) occlusion. The records of 21 patients during a 3-year period between 2005 and 2008 were retrieved from the in-hospital registry. The first group included 10 patients (6 women and 4 men; median age 78 years) with acute embolic occlusion of the SMA. The median duration of symptoms from symptom onset to angiography was 30 hours (range 6 to 120). Synchronous emboli (n = 12) occurred in 6 patients. Embolus aspiration was performed in 9 patients, and 7 of these had satisfactory results. Complementary local thrombolysis was successful in 2 of 3 patients. Residual emboli were present at completion angiography in all 7 patients who underwent successful aspiration embolectomy, and bowel resection was necessary in only 1 of these patients. One serious complication occurred because of a long SMA dissection. The in-hospital survival rate was 90% (9 of 10 patients). The second group included 11 patients (10 women and 1 man; median age 68 years) with atherosclerotic acute SMA occlusions. The median time of symptom duration before intervention was 97 hours (range 17 to 384). The brachial, femoral, and SMA routes were used in 6, 7, and 5 patients, respectively. SMA stenting was performed through an antegrade (n = 7) or retrograde (n = 3) approach. Bowel resection was necessary in 4 patients. No major complications occurred. The in-hospital survival rate was 82% (9 of 11 patients). Endovascular therapy of acute SMA occlusion provides a good alternative to open surgery.

  9. Clinical outcomes of endovascularly managed iatrogenic renal hemorrhages

    International Nuclear Information System (INIS)

    Chiramel, George Koshy; Keshava, Shyamkumar Nidugala; Moses, Vinu; Kekre, Nitin; Tamilarasi, V; Devasia, Anthony

    2015-01-01

    To evaluate the effectiveness of endovascular management in iatrogenic renal injuries with regard to clinical status on follow-up and requirements for repeat angiography and embolization. This retrospective study included patients who were referred for endovascular management of significant hemorrhage following an iatrogenic injury. Data was recorded from the Picture Archiving and Communication system (PACS) and electronic medical records. The site and type of iatrogenic injury, imaging findings, treatment, angiography findings, embolization performed, clinical status on follow-up, and requirement for repeat embolization were recorded. The outcomes were clinical resolution, nephrectomy, or death. Clinical findings were recorded on follow-up visits to the clinic. Statistical analysis was performed using descriptive statistics. Seventy patients were included in this study between January 2000 and June 2012. A bleeding lesion (a pseudoaneurysm or arteriovenous fistula) was detected during the first angiogram in 55 patients (78.6%) and was selectively embolized. Fifteen required a second angiography as there was no clinical improvement and five required a third angiography. Overall, 66 patients (94.3%) showed complete resolution and 4 patients (5.7%) died. Three patients (4.3%) underwent nephrectomy for clinical stabilization even after embolization. There were no major complications. The two minor complications resolved spontaneously. Angiography and embolization is the treatment of choice in iatrogenic renal hemorrhage. Upto 20% of initial angiograms may not reveal the bleed and repeat angiography is required to identify a recurrent or unidentified bleed. The presence of multiple punctate bleeders on angiography suggests an enlarging subcapsular hematoma and requires preoperative embolization and nephrectomy

  10. EVAR: Benefits of CEUS for monitoring stent-graft status

    International Nuclear Information System (INIS)

    Cantisani, Vito; Grazhdani, Hektor; Clevert, Dirk-André; Iezzi, Roberto; Aiani, Luca; Martegani, Alberto; Fanelli, Fabrizio; Di Marzo, Luca; Wlderk, Andrea; Cirelli, Carlo; Catalano, Carlo; Di Leo, Nicola; Di Segni, Mattia; Malpassini, Flavio; D’Ambrosio, Ferdinando

    2015-01-01

    Highlights: • In the last two decades several studies have shown the role of contrast enhanced ultrasound [CEUS] in post-EVAR surveillance, with very good diagnostic performance, absence of renal impairment, and no radiation, accompanied by low costs, in comparison with CTA. • In numerous prospective studies and meta-analyses the detection and characterization of endoleaks with CEUS is comparable to that of CTA imaging. • Nowadays in the EVAR surveillance novel strategies which involve CEUS with a central role, are suggested by several authors and applied in many institutions. • CEUS technique, findings, diagnostic accuracy, and its role in the follow up program are discussed in this review article. - Abstract: Endo vascular aortic repair [EVAR] is performed with low peri-operative morbidity and mortality rate and short hospital stay. However, EVAR needs a close and lifelong imagining surveillance for a timely detection of possible complications including endoleaks, graft migration, fractures, and enlargement of aneurysm sac size with eventual rupture. Contrast enhanced computed tomography [CTA] is actually considered the gold-standard in EVAR follow-up, but it is accompanied with radiation burden and renal injury due to the use of contrast media. In the last two decades several studies have shown the role of contrast enhanced ultrasound [CEUS] in post-EVAR surveillance, with very good diagnostic performance, absence of renal impairment, and no radiation, accompanied by low costs, in comparison with CTA. In numerous prospective studies and meta-analyses the detection and characterization of endoleaks with CEUS is comparable to that of CTA imaging. Nowadays, in the EVAR surveillance novel strategies which involve CEUS with a central role, are suggested by several authors and applied in many institutions. In this review article we will present a comprehensive overview and analyses of the literature on the CEUS state-of-art imagining of EVAR follow-up, with its technique, findings, diagnostic accuracy, and its role in the follow up program

  11. Megarectumsigma underwent surgery for chronic faecal impact action

    International Nuclear Information System (INIS)

    Canessa, C.; Gomez del Valle, M.; Caraballo, M.

    2002-01-01

    Seven patients with megarectumsigma underwent surgery for chronic faecal impaction,reviewing clinical diagnosis, aetiology and medical and surgical management.It is suggested medical management of chronic faecal impaction trying to achieve elective surgery.The curative surgery should include the resection of all pathologic bowel, but in Duhamel procedure and its modifications distal rectal tran section should be at the peritoneal reflection.Habr-Gama modification has shown to be technically easier and it has been communicated good functional results.Local unfavourable conditions may be resolve by staged surgery,which allows outline definitive bowel reconstruction after functional assessment

  12. ENDOVASCULAR PRELUDE FOR DELICATE MENINGEOMA OPERATION: A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Aleksandar Kostic

    2017-04-01

    Full Text Available Introduction: Embolization prior to surgery can make tumor resection less complicated by reducing blood loss during surgery and shortening the time of the operation. Case report: In this paper, we presented a case of a sixty-three-year-old woman who was admitted to the Clinic of Neurosurgery, Clinical Center Niš, Serbia, at November 2016, after she underwent a CT brain scan that showed a large tumor of the left cerebellopontile angle. Digital subtraction angiography presented a large, highly vascularized tumor lesion that compressed the brain stem. The patient underwent endovascular procedure, and complete embolization of the tumor vessels was established. The radiologist delivered embolization material via the left ascending pharyngeal artery. In the next 24 hours, an operation was performed i.e. radical extirpation surgery (Simpson grade I. Postoperatively, the patient’s GCS was 15, with no new neurological deficit. Postoperative brain CT scan showed neither rest tumor nor blood clot inside the tumor bed. Pathohistological finding revealed atypical meningioma grade II. Conslusion: Despite some clinicians’ dilemma considering the utility of preoperative embolization of meningioma vessels, we believe that a team of educated and dedicated radiologist and neurosurgeon could achieve great results in resection of large and inaccessible cranial tumors.

  13. Endovascular Treatment of Chronic Mesenteric Ischemia: Report of Five Cases

    International Nuclear Information System (INIS)

    Nyman, Ulf; Ivancev, Krasnodar; Lindh, Mats; Uher, Petr

    1998-01-01

    Purpose: To evaluate the midterm results of percutaneous transluminal angioplasty (PTA) and stent placement in stenotic and occluded mesenteric arteries in five consecutive patients with chronic mesenteric ischemia. Methods: Five patients with 70%-100% obliterations of all mesenteric vessels resulting in chronic mesenteric ischemia (n= 4) and as a prophylactic measure prior to abdominal aortic aneurysm repair (n= 1) underwent PTA of celiac and/or superior mesenteric artery (SMA) stenoses (n= 2), primary stenting of ostial celiac occlusions (n= 2), and secondary stenting of a SMA occlusion (n= 1; recoil after initial PTA). All patients underwent duplex ultrasonography (US) (n= 3) and/or angiography (n= 5) during a median follow-up of 21 months (range 8-42 months). Results: Clinical success was obtained in all five patients. Asymptomatic significant late restenoses (n3) were successfully treated with repeat PTA (n= 2) and stenting of an SMA occlusion (n= 1; celiac stent restenosis). Recurrent pain in one patient was interpreted as secondary to postsurgical abdominal adhesions. Two puncture-site complications occurred requiring local surgical treatment. Conclusions: Endovascular techniques may be attempted prior to surgery in cases of stenotic or short occlusive lesions in patients with chronic mesenteric ischemia. Surgery may still be preferred in patients with long occlusions and a low operative risk

  14. Endovascular Embolization of Intracranial Infectious Aneurysms in Patients Undergoing Open Heart Surgery Using n-Butyl Cyanoacrylate.

    Science.gov (United States)

    Cheng-Ching, Esteban; John, Seby; Bain, Mark; Toth, Gabor; Masaryk, Thomas; Hui, Ferdinand; Hussain, Muhammad Shazam

    2017-03-01

    Mycotic aneurysms are a serious complication of infective endocarditis with increased risk of intracranial hemorrhage. Patients undergoing open heart surgery for valve repair or replacement are exposed to anticoagulants, increasing the risk of aneurysm bleeding. These patients may require endovascular or surgical aneurysm treatment prior to heart surgery, but data on this approach are scarce. Retrospective review of consecutive patients with infectious endocarditis and mycotic aneurysms treated endovascularly with Trufill n-butyl cyanoacrylate (n-BCA) at the Cleveland Clinic between January 2013 and December 2015. Nine patients underwent endovascular treatment of mycotic aneurysms with n-BCA (mean age of 39 years). On imaging, 4 patients had intracerebral hemorrhage, 2 had multiple embolic infarcts, and the rest had no imaging findings. Twelve mycotic aneurysms were detected (3 patients with 2 aneurysms). Seven aneurysms were in the M4 middle cerebral artery segment, 4 in the posterior cerebral artery distribution, and 1 in the callosomarginal branch. n-BCA was diluted in ethiodized oil (1:1 to 1:2). Embolization was achieved in a single rapid injection with immediate microcatheter removal. Complete aneurysm exclusion was achieved in all cases without complications. All patients underwent open heart surgery and endovascular embolization within a short interval, 2 with both procedures on the same day. There were no new hemorrhages after aneurysm embolization. Endovascular embolization of infectious intracranial aneurysms with liquid embolics can be performed successfully in critically ill patients requiring immediate open heart surgery and anticoagulation. Early embolization prior to and within a short interval from open heart surgery is feasible.

  15. Combined Endovascular Treatment with Distal Radial Artery Coil Embolization and Angioplasty in Steal Syndrome Associated with Forearm Dialysis Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Tercan, Fahri, E-mail: ftercan@yahoo.com; Koçyiğit, Ali, E-mail: alkoc@yahoo.com [Pamukkale University, Department of Radiology, School of Medicine (Turkey); Güney, Bünyamin [Muğla Sıtkı Kocman University, Department of Radiology, School of Medicine (Turkey)

    2016-09-15

    PurposeThe present study was performed to define the results of the endovascular treatment with angioplasty and distal radial artery embolization in ischemic steal syndrome associated with forearm arteriovenous accesses.MethodThe cases referred to our interventional radiology unit with symptoms and physical examination findings suggestive of ischemic steal syndrome were retrospectively evaluated first by Doppler ultrasonography, and then by angiography. Cases with proximal artery stenosis were applied angioplasty, and those with steal syndrome underwent coil embolization to distal radial artery.ResultsOf 589 patients who underwent endovascular intervention for dialysis arteriovenous fistulae (AVF)-associated problems, 6 (1.01 %) (5 female, 1 males; mean age 62 (range 41–78) with forearm fistula underwent combined endovascular treatment for steal syndrome. In addition to steal phenomenon, there were stenosis and/or occlusion in proximal radial and/or ulnar artery in 6 patients concurrently. Embolization of distal radial artery and angioplasty to proximal arterial stenoses were performed in all patients. Ischemic symptoms were eliminated in all patients and the AVF were in use at the time of study. In one patient, ischemic symptoms recurring 6 months later were alleviated by repeat angioplasty of ulnar artery.ConclusionIn palmar arch steal syndrome affecting forearm fistulae, combined distal radial embolization and angioplasty is also an effective treatment method in the presence of proximal radial and ulnar arterial stenoses and occlusions.

  16. Hybrid Endovascular Aortic Aneurysm Repair: Preservation of Pelvic Perfusion with External to Internal Iliac Artery Bypass.

    Science.gov (United States)

    Mansukhani, Neel A; Havelka, George E; Helenowski, Irene B; Rodriguez, Heron E; Hoel, Andrew W; Eskandari, Mark K

    2017-07-01

    Diminished pelvic arterial flow as a result of intentional coverage/embolization of internal iliac arteries (IIA) during isolated endovascular common iliac artery aneurysm (CIAA) repair or endovascular repair of abdominal aortic aneurysms (EVAR) may result in symptomatic pelvic ischemia. Although generally well tolerated, in severe cases, pelvic ischemia may manifest as recalcitrant buttock claudication, vasculogenic impotence, or perineal, vesicle, rectal, and/or spinal cord ischemia. Branched graft technology has recently become available; however, many patients are not candidates for endovascular repair with these devices. Therefore, techniques to preserve pelvic arterial flow are needed. We reviewed our outcomes of isolated endovascular CIAA repair or EVAR in conjunction with unilateral external-internal iliac artery bypass. Single-center, retrospective review of 10 consecutive patients who underwent hybrid endovascular abdominal aortic aneurysm (AAA) or CIAA repair with concomitant external-internal iliac artery bypass between 2006 and 2015. Demographics, index procedural details, postoperative symptoms, hospital length of stay (LOS), follow-up imaging, and bypass patency were recorded. The cohort of 10 patients was all men with a mean age of 71 years (range: 56-84). Hybrid repair consisted of contralateral IIA coil embolization followed by EVAR with external iliac artery-internal iliac artery (EIA-IIA) bypass. All EIA-IIA bypasses were performed via a standard lower quadrant retroperitoneal approach with a prosthetic bypass graft. Technical success was 100%, and there were no perioperative deaths. One patient developed transient paraplegia, 1 patient had buttock claudication on the side of his hypogastric embolization contralateral to his iliac bypass, and 1 developed postoperative impotence. 20% of patients sustained long-term complications (buttock claudication and postoperative impotence). Mean LOS was 2.8 days (range: 1-9 days). Postoperative imaging

  17. Preliminary clinical study on endovascular treatment of posterior inferior cerebellar artery aneurysms

    International Nuclear Information System (INIS)

    Zhao Bing; Zhong Ming; Tan Xianxi; Zheng Kuang; Zhang Mingsheng; Yin Jian; He Wengen

    2009-01-01

    Objective: To study the methods and results of endovascular treatment of posterior inferior cerebellar artery (PICA) aneurysms. Methods: Twenty-one patients with PICA aneurysms were treated with endovascular treatment. The locations of aneurysm on PICA were evaluated through the DSA. Eight patients received single coil embolization, 5 received liquid Glue embolization, 2 received coil embolization combined with liquid Glue, 2 received coil embolization assisted with stents, and 4 underwent occlusion of the parent PICA. Outcome was evaluated with the Glasgow outcome scale (GOS). Results: There were complete (100%) occlusion in 5 patients, near complete (> 90%) occlusion in 2, and incomplete (85%) occlusion in 1 in single coil embolization. Seven patients with Glue embolization (n=5) or combination with coils (n=2) exhibited complete (100%) occlusion. There were near complete (>90%) occlusion in 2 cases with coil assisted with stents. Complete occlusion of the parent PICA was achieved in 3 patients, and near complete occlusion of PICA in one case. One patient suffered from new neurological deficits, and one patient treated with coils and stents died. None of the patients suffered from re-bleeding. There patients received follow-up during a mean period of (22 ± 8) months. Overall long-term outcome was good (GOS score 4 or 5) in 17 patients, poor (GOS score 2 or 3) in 3, and fatal (GOS score 1 ) in one case. Conclusions: According to the location of aneurysms on PICA, aneurysms can be effectively and safely treated with endovascular embolization. (authors)

  18. Endovascular Management of Deep venous Thrombosis of Lower Extremity in Patients with Malignant Disease

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Su Jin; Kim, Jae Kyu; Jang, Nam Kyu; Han, Seung Min; Kang, Heoung Keun; Choi, Soo Jin Nah [Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2009-07-15

    To evaluate the efficacy of endovascular management of lower extremity deep vein thrombosis (DVT) in patients with malignant disease. Between January 2002 and January 2008, six consecutive patients (5 male and 1 female, mean age-65 years) with lower extremity DVT and malignant disease underwent endovascular management. The duration of symptoms lasted 4-120 days (mean-31 days; 20 days or less in four patients and more than 20 days in two). A catheter-directed thrombolysis was performed via the ipsilateral popliteal vein or common femoral vein, used alone or combined with a percutaneous mechanical thrombectomy. Angioplasty or stent placement was performed in residual stenosis or occlusion of the vein. The follow-up period lasted 1-14 months (mean 7.6 months) and was performed via a color Doppler ultrasonography or computed tomographic venography. Technical success and relief from symptoms was achieved within two days was achieved in five patients. Minor hemorrhagic complications occurred in two cases: hematuria and a hematoma at the puncture site. Upon follow-up, a recurrent DVT occurred in three patients as well as a patent venous flow in two. One patient died within 1 month due to a metastatic mediastinal lymphadenopathy. Endovascular management of the lower extremity DVT is effective for quickly eliminating a thrombus, relieving symptoms, and decreasing hemorrhagic complications in patients with malignant disease.

  19. Endovascular Management of Deep venous Thrombosis of Lower Extremity in Patients with Malignant Disease

    International Nuclear Information System (INIS)

    Jeong, Su Jin; Kim, Jae Kyu; Jang, Nam Kyu; Han, Seung Min; Kang, Heoung Keun; Choi, Soo Jin Nah

    2009-01-01

    To evaluate the efficacy of endovascular management of lower extremity deep vein thrombosis (DVT) in patients with malignant disease. Between January 2002 and January 2008, six consecutive patients (5 male and 1 female, mean age-65 years) with lower extremity DVT and malignant disease underwent endovascular management. The duration of symptoms lasted 4-120 days (mean-31 days; 20 days or less in four patients and more than 20 days in two). A catheter-directed thrombolysis was performed via the ipsilateral popliteal vein or common femoral vein, used alone or combined with a percutaneous mechanical thrombectomy. Angioplasty or stent placement was performed in residual stenosis or occlusion of the vein. The follow-up period lasted 1-14 months (mean 7.6 months) and was performed via a color Doppler ultrasonography or computed tomographic venography. Technical success and relief from symptoms was achieved within two days was achieved in five patients. Minor hemorrhagic complications occurred in two cases: hematuria and a hematoma at the puncture site. Upon follow-up, a recurrent DVT occurred in three patients as well as a patent venous flow in two. One patient died within 1 month due to a metastatic mediastinal lymphadenopathy. Endovascular management of the lower extremity DVT is effective for quickly eliminating a thrombus, relieving symptoms, and decreasing hemorrhagic complications in patients with malignant disease

  20. Surgical Clipping versus Endovascular Intervention for the Treatment of Subarachnoid Hemorrhage Patients in New York State.

    Directory of Open Access Journals (Sweden)

    Kimon Bekelis

    Full Text Available Randomized trials have demonstrated a survival benefit for endovascular treatment of ruptured cerebral aneurysms. We investigated the association of surgical clipping and endovascular coiling with outcomes in subarachnoid hemorrhage (SAH patients in a real-world regional cohort.We performed a cohort study involving patients with ruptured cerebral aneurysms, who underwent surgical clipping, or endovascular coiling from 2009-2013 and were registered in the Statewide Planning and Research Cooperative System (SPARCS database. An instrumental variable analysis was used to investigate the association of treatment technique with outcomes.Of the 4,098 patients undergoing treatment, 2,585 (63.1% underwent coiling, and 1,513 (36.9% underwent clipping. Using an instrumental variable analysis, we did not identify a difference in inpatient mortality [marginal effect (ME, -0.56; 95% CI, -1.03 to 0.02], length of stay (LOS (ME, 1.72; 95% CI, -3.39 to 6.84, or the rate of 30-day readmissions (ME, -0.30; 95% CI, -0.82 to 0.22 between the two treatment techniques for patients with SAH. Clipping was associated with a higher rate of discharge to rehabilitation (ME, 0.63; 95% CI, 0.24 to 1.01. In sensitivity analysis, mixed effect regression, and propensity score adjusted regression models demonstrated identical results.Using a comprehensive all-payer cohort of patients in New York State presenting with aneurysmal SAH we did not identify an association of treatment method with mortality, LOS or 30-day readmission. Clipping was associated with a higher rate of discharge to rehabilitation.

  1. ALGORITHM FOR MANAGEMENT OF HYPERTENSIVE PATIENTS UNDERWENT UROLOGY INTERVENTIONS

    Directory of Open Access Journals (Sweden)

    S. S. Davydova

    2013-01-01

    Full Text Available Aim. To study the efficacy of cardiovascular non-invasive complex assessment and pre-operative preparation in hypertensive patients needed in surgical treatment of urology dis- eases.Material and methods. Males (n=883, aged 40 to 80 years were included into the study. The main group consisted of patients that underwent laparotomic nephrectomy (LTN group; n=96 and patients who underwent laparoscopic nephrectomy (LSN group; n=53. Dynamics of ambulatory blood pressure monitoring (ABPM data was analyzed in these groups in the immediate postoperative period. The efficacy of a package of non-invasive methods for cardiovascular system assessment was studied. ABPM was performed after nephrectomy (2-nd and 10-th days after surgery in patients with complaints of vertigo episodes or intense general weakness to correct treatment.Results. In LTN group hypotension episodes or blood pressure (BP elevations were observed in 20 (20.8% and 22 (22.9% patients, respectively, on the 2-nd day after the operation. These complications required antihypertensive treatment correction. Patients with hypotension episodes were significantly older than patients with BP elevation and had significantly lower levels of 24-hour systolic BP, night diastolic BP and minimal night systolic BP. Re-adjustment of antihypertensive treatment on the 10-th postoperative day was required to 2 (10% patients with hypotension episodes and to 1 (4.5% patient with BP elevation. Correction of antihypertensive therapy was required to all patients in LSN group on the day 2, and to 32 (60.4% patients on the 10-th day after the operation. Reduction in the incidence of complications (from 1.2% in 2009 to 0.3% in 2011, p<0.001 was observed during the application of cardiovascular non-invasive complex assessment and preoperative preparation in hypertensive patients.Conclusion. The elaborated management algorithm for patients with concomitant hypertension is recommended to reduce the cardiovascular

  2. ALGORITHM FOR MANAGEMENT OF HYPERTENSIVE PATIENTS UNDERWENT UROLOGY INTERVENTIONS

    Directory of Open Access Journals (Sweden)

    S. S. Davydova

    2015-09-01

    Full Text Available Aim. To study the efficacy of cardiovascular non-invasive complex assessment and pre-operative preparation in hypertensive patients needed in surgical treatment of urology dis- eases.Material and methods. Males (n=883, aged 40 to 80 years were included into the study. The main group consisted of patients that underwent laparotomic nephrectomy (LTN group; n=96 and patients who underwent laparoscopic nephrectomy (LSN group; n=53. Dynamics of ambulatory blood pressure monitoring (ABPM data was analyzed in these groups in the immediate postoperative period. The efficacy of a package of non-invasive methods for cardiovascular system assessment was studied. ABPM was performed after nephrectomy (2-nd and 10-th days after surgery in patients with complaints of vertigo episodes or intense general weakness to correct treatment.Results. In LTN group hypotension episodes or blood pressure (BP elevations were observed in 20 (20.8% and 22 (22.9% patients, respectively, on the 2-nd day after the operation. These complications required antihypertensive treatment correction. Patients with hypotension episodes were significantly older than patients with BP elevation and had significantly lower levels of 24-hour systolic BP, night diastolic BP and minimal night systolic BP. Re-adjustment of antihypertensive treatment on the 10-th postoperative day was required to 2 (10% patients with hypotension episodes and to 1 (4.5% patient with BP elevation. Correction of antihypertensive therapy was required to all patients in LSN group on the day 2, and to 32 (60.4% patients on the 10-th day after the operation. Reduction in the incidence of complications (from 1.2% in 2009 to 0.3% in 2011, p<0.001 was observed during the application of cardiovascular non-invasive complex assessment and preoperative preparation in hypertensive patients.Conclusion. The elaborated management algorithm for patients with concomitant hypertension is recommended to reduce the cardiovascular

  3. Endovascular repair of an innominate artery pseudoaneurysm using the Valiant Mona LSA branched graft device

    Directory of Open Access Journals (Sweden)

    Josh A. Sibille, MD

    2017-03-01

    Full Text Available A 60-year-old woman involved in a motor vehicle collision presented with a traumatic pseudoaneurysm of the innominate artery origin in addition to multiple concomitant injuries. She was classified as a high-risk candidate for open repair. An experimental thoracic branched graft device was used for coverage of the injury with the addition of a right carotid-to-left carotid-to-left subclavian artery bypass. Follow-up imaging showed resolution of the pseudoaneurysm and patency of her bypass grafts. This is the first described use of the Mona LSA Branch Thoracic Stent Graft System (Medtronic, Minneapolis, Minn in the innominate artery.

  4. Endovascular Treatment of a Splenic Aneurysm Associated With Segmental Arterial Mediolysis

    Directory of Open Access Journals (Sweden)

    A. Khan

    Full Text Available : Introduction: Segmental arterial mediolysis is a rare disorder characterised by disintegration of the medial layer of an arterial wall usually affecting the intra-abdominal splanchnic vessels. Report: A case of 50 year old man who presented with sudden-onset left sided flank pain is reported. A computed tomography mesenteric angiogram showed haemorrhage and a stable left upper quadrant haematoma arising from 8 × 8 mm splenic artery aneurysm. Discussion: The patient underwent a successful endovascular coiling procedure to exclude the aneurysm and for complete resolution of his symptoms. Keywords: Segmental arterial mediolysis, Splanchnic vessels, Splenic artery aneurysm

  5. "Elephant trunk" and endovascular stentgrafting : a hybrid approach to the treatment of extensive thoracic aortic aneurysm

    OpenAIRE

    Holubec, Tomás; Raupach, Jan; Dominik, Jan; Vojácek, Jan

    2013-01-01

    A hybrid approach to elephant trunk technique for treatment of thoracic aortic aneurysms combines a conventional surgical and endovascular therapy. Compared to surgery alone, there is a presumption that mortality and morbidity is reduced. We present a case report of a 42-year-old man with a giant aneurysm of the entire thoracic aorta, significant aortic and tricuspid regurgitation and ventricular septum defect. The patient underwent multiple consecutive operations and interventions having, am...

  6. Emergency endovascular coiling of a ruptured giant splenic artery aneurysm

    DEFF Research Database (Denmark)

    Wernheden, Erika; Brenøe, Anne Sofie; Shahidi, Saeid

    2017-01-01

    Splenic artery aneurysms (SAAs) are the third most common abdominal aneurysm. Endovascular treatment of SAAs is preferred, and coiling is the most commonly used technique. Ruptured giant (>5 cm) SAAs are usually treated with open surgery including splenectomy. We present a rare case of a ruptured...... 15-cm giant SAA in an 84-year-old woman treated successfully with emergency endovascular coiling. To our knowledge, this is one of the few reports of emergency endovascular treatment for ruptured giant SAA....

  7. Endovascular Management of Acute Embolic Occlusion of the Superior Mesenteric Artery: A 12-Year Single-Centre Experience

    International Nuclear Information System (INIS)

    Raupach, J.; Lojik, M.; Chovanec, V.; Renc, O.; Strýček, M.; Dvořák, P.; Hoffmann, P.; Guňka, I.; Ferko, A.; Ryška, P.; Omran, N.; Krajina, A.; Čabelková, P.; Čermáková, E.; Malý, R.

    2016-01-01

    PurposeRetrospective evaluation of 12-year experience with endovascular management of acute mesenteric ischemia (AMI) due to embolic occlusion of the superior mesenteric artery (SMA).Materials and methodsFrom 2003 to 2014, we analysed the in-hospital mortality of 37 patients with acute mesenteric embolism who underwent primary endovascular therapy with subsequent on-demand laparotomy. Transcatheter embolus aspiration was used in all 37 patients (19 women, 18 men, median age 76 years) with embolic occlusion of the SMA. Adjunctive local thrombolysis (n = 2) and stenting (n = 2) were also utilised.ResultsWe achieved complete recanalization of the SMA stem in 91.9 %. One patient was successfully treated by surgical embolectomy due to a failed endovascular approach. Subsequent exploratory laparotomy was performed in 73.0 % (n = 27), and necrotic bowel resection in 40.5 %. The total in-hospital mortality was 27.0 %.ConclusionPrimary endovascular therapy for acute embolic SMA occlusion with on-demand laparotomy is a recommended algorithm used in our centre to treat SMA occlusion. This combined approach for the treatment of AMI is associated with in-hospital mortality rate of 27.0 %

  8. Endovascular Management of Acute Embolic Occlusion of the Superior Mesenteric Artery: A 12-Year Single-Centre Experience

    Energy Technology Data Exchange (ETDEWEB)

    Raupach, J., E-mail: janraupach@seznam.cz; Lojik, M., E-mail: miroslav.lojik@fnhk.cz; Chovanec, V., E-mail: chovanec.v@seznam.cz; Renc, O., E-mail: ondrejrenc@seznam.cz [Faculty of Medicine at Charles University and University Hospital, Department of Radiology (Czech Republic); Strýček, M., E-mail: m.strycek@gmail.com [Faculty of Medicine at Charles University (Czech Republic); Dvořák, P., E-mail: petr.dvorak@fnhk.cz; Hoffmann, P., E-mail: hoffmpet@fnhk.cz [Faculty of Medicine at Charles University and University Hospital, Department of Radiology (Czech Republic); Guňka, I., E-mail: gunka@email.cz; Ferko, A., E-mail: a.ferko@seznam.cz [Faculty of Medicine at Charles University and University Hospital, Department of Surgery (Czech Republic); Ryška, P., E-mail: ryska@fnhk.cz [Faculty of Medicine at Charles University and University Hospital, Department of Radiology (Czech Republic); Omran, N., E-mail: nidal81@gmail.com [Faculty of Medicine at Charles University and University Hospital, Department of Cardiac Surgery (Czech Republic); Krajina, A., E-mail: krajina@fnhk.cz; Čabelková, P., E-mail: pavla.cabelkova@fnhk.cz [Faculty of Medicine at Charles University and University Hospital, Department of Radiology (Czech Republic); Čermáková, E., E-mail: cermakovae@lfhk.cuni.cz [Faculty of Medicine at Charles University, Computer Technology Center (Czech Republic); Malý, R., E-mail: malyr@volny.cz [Faculty of Medicine at Charles University and University Hospital, Department of Medicine (Czech Republic)

    2016-02-15

    PurposeRetrospective evaluation of 12-year experience with endovascular management of acute mesenteric ischemia (AMI) due to embolic occlusion of the superior mesenteric artery (SMA).Materials and methodsFrom 2003 to 2014, we analysed the in-hospital mortality of 37 patients with acute mesenteric embolism who underwent primary endovascular therapy with subsequent on-demand laparotomy. Transcatheter embolus aspiration was used in all 37 patients (19 women, 18 men, median age 76 years) with embolic occlusion of the SMA. Adjunctive local thrombolysis (n = 2) and stenting (n = 2) were also utilised.ResultsWe achieved complete recanalization of the SMA stem in 91.9 %. One patient was successfully treated by surgical embolectomy due to a failed endovascular approach. Subsequent exploratory laparotomy was performed in 73.0 % (n = 27), and necrotic bowel resection in 40.5 %. The total in-hospital mortality was 27.0 %.ConclusionPrimary endovascular therapy for acute embolic SMA occlusion with on-demand laparotomy is a recommended algorithm used in our centre to treat SMA occlusion. This combined approach for the treatment of AMI is associated with in-hospital mortality rate of 27.0 %.

  9. Manejo endovascular de la aorta torácica Endovascular treatment of thoracic aorta

    Directory of Open Access Journals (Sweden)

    Juan G Barrera

    2006-10-01

    Full Text Available En comparación con el tratamiento convencional, la terapia endovascular en aneurisma de aorta torácica, presenta los mejores resultados, por lo que se convierte en el tratamiento de elección para la patología de aorta torácica descendente endovascular, por su baja morbimortalidad perioperatoria. El tratamiento quirúrgico por vía retroperitoneal y/o endovascular para aneurisma de aorta abdominal infrarrenal, resulta ser especialmente seguro en pacientes octogenarios o con alta morbilidad. Esta cohorte institucional presenta resultados perioperatorios y en el seguimiento, similares a los reportados en la literatura mundial.Compared with the conventional treatment, endovascular therapy in thoracic aortic aneurysm shows the best results, being the election treatment for the pathology of the descending thoracic aorta, due to its low peri-operative morbid-mortality. Surgical treatment by retro-peritoneal route and/or endovascular for infra-renal abdominal aortic aneurysm is especially safe in octogenarian patients or in those with a high mortality rate. This institutional cohort show peri-operative and follow-up results similar to those reported in the world literature.

  10. Endovascular treatment of peripheral and visceral arterial injuries in patients with acute trauma.

    Science.gov (United States)

    Erbahçeci Salık, Aysun; Saçan İslim, Filiz; Çil, Barbaros Erhan

    2016-11-01

    The present study is an evaluation of the efficacy of endovascular treatment in emergency setting for patients with acute peripheral and visceral arterial injury secondary to penetrating or blunt trauma. Twelve patients (11 men) aged 35.8±11.3 years (range: 18-56 years) with penetrating or blunt trauma who underwent endovascular treatment in our department between March 2010 and June 2014 for peripheral and visceral arterial injury were retrospectively reviewed. Selective coil embolization was performed on 11 patients and particle embolization of the injured vessel was performed on 1 patient. Criteria for endovascular treatment included active extravasation or pseudoaneurysm on contrast-enhanced computed tomography and decrease in hemoglobin level or temporary hemodynamic instability. Arterial injuries were secondary to penetrating injury due to gunshot wound in 4 patients and stab wound in 5, and blunt abdominal injury as result of traffic accident in 3 patients. Traumatic lesions were in the right hepatic artery (n=3), left hepatic (n=2), right hepatic and right renal (n=1), left inferior epigastric (n=2), left facial (n=1), anterior tibial (n=1), and deep femoral (n=1) arteries. Technical success with no procedural complications was seen in all cases. Two patients died due to coexisting injuries on 29th and 43rd days of hospitalization. Median hospitalization period was 6.0 days (range: 1-43 days) and mean intensive care unit hospitalization was 7.7 days (range: 0-43 days). In our experience, endovascular treatment was a safe and effective option for acute traumatic peripheral and visceral arterial lesions.

  11. Endovascular treatment of spine and spinal cord lesions

    International Nuclear Information System (INIS)

    Berenstein, A.

    1992-01-01

    Completing this comprehensive series on endovascular interventional angiography, Volume 5 focuses on the vascular abnormalities of the spine and spinal cord. It is based on the detailed functional vascular anatomy described in Volume 3 and the principles and function of endovascular treatment described in Volumes 1-4. As in the companion volumes, the unique approach gives view of the disease itself, its anatomical features and its clinical presentation. The technical aspects of the interventional or endovascular neuroradiology are built upon the solid analysis of the disease and its angioarchitecture. The recent developments in endovascular procedures, such as aneurysm treatment, angioplasty, and vascular recanalizations, are reviewed. (orig.). 118 figs. in 442 separate illustrations

  12. Intraoperative seizures and seizures outcome in patients underwent awake craniotomy.

    Science.gov (United States)

    Yuan, Yang; Peizhi, Zhou; Xiang, Wang; Yanhui, Liu; Ruofei, Liang; Shu, Jiang; Qing, Mao

    2016-11-25

    Awake craniotomies (AC) could reduce neurological deficits compared with patients under general anesthesia, however, intraoperative seizure is a major reason causing awake surgery failure. The purpose of the study was to give a comprehensive overview the published articles focused on seizure incidence in awake craniotomy. Bibliographic searches of the EMBASE, MEDLINE,were performed to identify articles and conference abstracts that investigated the intraoperative seizure frequency of patients underwent AC. Twenty-five studies were included in this meta-analysis. Among the 25 included studies, one was randomized controlled trials and 5 of them were comparable studies. The pooled data suggested the general intraoperative seizure(IOS) rate for patients with AC was 8%(fixed effect model), sub-group analysis identified IOS rate for glioma patients was 8% and low grade patients was 10%. The pooled data showed early seizure rates of AC patients was 11% and late seizure rates was 35%. This systematic review and meta-analysis shows that awake craniotomy is a safe technique with relatively low intraoperative seizure occurrence. However, few RCTs were available, and the acquisition of further evidence through high-quality RCTs is highly recommended.

  13. Endovascular treatment of very small intracranial aneurysms

    DEFF Research Database (Denmark)

    Iskandar, A; Nepper-Rasmussen, J

    2011-01-01

    to large aneurysms (> 3 mm). However the data also suggest that endovascular treatment of very small aneurysms might be associated with an increased risk of procedural ruptures and mortality. At nine-month follow-up results indicate significantly less compaction in the very small aneurysms....... endovascular treatment was attempted in 956 consecutive intracranial aneurysms. Of 956 aneurysms, 111 aneurysms were very small aneurysms with a maximal diameter of 3 mm or less. We conducted a retrospective analysis of angiographic and clinical outcome following coiling of very small aneurysms...... aneurysms and less than 90% aneurysm occlusion in six aneurysms. Complications occurred in the treatment of 15 aneurysms, including eight procedural ruptures, six thromboembolic events and one case of early hemorrhage. Compared with larger aneurysms, treatment of very small aneurysms was associated...

  14. Intestinal infarction: A complication of endovascular therapy

    International Nuclear Information System (INIS)

    England, Andrew; Butterfield, John S.; Sukumar, Sathi; Thompson, David; Roulson, Jo-An; Pritchard, Susan; Ashleigh, Raymond J.

    2007-01-01

    This report presents a rare case of intestinal infarction following endovascular therapy. A female patient who had undergone an internal carotid artery stenting procedure presented suddenly with abdominal pain. Radiological and clinical examinations at the time suggested a picture of intestinal ischaemia, in view of the patient's general conditions and co-existing morbidities surgical intervention was not considered to be an option. The patient died 4 days after the carotid stenting procedure, post-mortem examination revealed infarction of the ileum and caecum. The learning outcomes are if performing endovascular therapy in a patient with diffuse atherosclerotic disease early consideration of intestinal ischaemia should be given to any patient who presents with acute post-procedural abdominal pain

  15. Endovascular revascularization for aortoiliac atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Aggarwal V

    2016-03-01

    Full Text Available Vikas Aggarwal,1 Stephen W Waldo,2,3 Ehrin J Armstrong2,3 1Prairie Heart Institute, St John's Hospital, Springfield, IL, 2Section of Cardiology, Denver Veterans Affairs Medical Center, 3Section of Cardiology, University of Colorado, Aurora, CO, USA Abstract: Atherosclerotic iliac artery disease is increasingly being treated with endovascular techniques. A number of new stent technologies can be utilized with high long-term patency, including self-expanding stents, balloon-expandable stents, and covered stents, but comparative data on these stent types and in more complex lesions are lacking. This article provides a review of currently available iliac stent technologies, as well as complex procedural aspects of iliac artery interventions, including approaches to the treatment of iliac bifurcation disease, long segment occlusions, choice of stent type, and treatment of iliac artery in-stent restenosis. Keywords: peripheral artery disease, iliac artery, balloon expandable stent, self expanding stent, covered stent, claudication, endovascular

  16. Intestinal infarction: A complication of endovascular therapy

    Energy Technology Data Exchange (ETDEWEB)

    England, Andrew [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom)]. E-mail: andrew.england@smtr.nhs.uk; Butterfield, John S. [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Sukumar, Sathi [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Thompson, David [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Roulson, Jo-An [Department of Histopathology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Pritchard, Susan [Department of Histopathology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Ashleigh, Raymond J. [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom)

    2007-08-15

    This report presents a rare case of intestinal infarction following endovascular therapy. A female patient who had undergone an internal carotid artery stenting procedure presented suddenly with abdominal pain. Radiological and clinical examinations at the time suggested a picture of intestinal ischaemia, in view of the patient's general conditions and co-existing morbidities surgical intervention was not considered to be an option. The patient died 4 days after the carotid stenting procedure, post-mortem examination revealed infarction of the ileum and caecum. The learning outcomes are if performing endovascular therapy in a patient with diffuse atherosclerotic disease early consideration of intestinal ischaemia should be given to any patient who presents with acute post-procedural abdominal pain.

  17. Trends in treatment of ruptured abdominal aortic aneurysm: impact of endovascular repair and implications for future care.

    Science.gov (United States)

    Park, Brian D; Azefor, Nchang; Huang, Chun-Chih; Ricotta, John J

    2013-04-01

    Our aim was to determine national trends in treatment of ruptured abdominal aortic aneurysm (RAAA), with specific emphasis on open surgical repair (OSR) and endovascular aneurysm repair (EVAR) and its impact on mortality and complications. Data from the Nationwide Inpatient Sample (NIS) from 2005 to 2009 were queried to identify patients older than 59 years with RAAA. Three groups were studied: nonoperative (NO), EVAR, and OSR. Chi-square analysis was used to determine the relationship between treatment type and patient demographics, clinical characteristics, and hospital type. The impact of EVAR compared with OSR on mortality and overall complications was examined using logistic regression analysis. We identified 21,206 patients with RAAA from 2005 to 2009, of which 16,558 (78.1%) underwent operative repair and 21.8% received no operative treatment. In the operative group, 12,761 (77.1%) underwent OSR and 3,796 (22.9%) underwent EVAR. Endovascular aneurysm repair was more common in teaching hospitals (29.1% vs 15.2%, p < .0001) and in urban versus rural settings. Nonoperative approach was twice as common in rural versus urban hospitals. Reduced mortality was seen in patients transferred from another institutions (31.2% vs 39.4%, p = 0.014). Logistic regression analysis demonstrated a benefit of EVAR on both complication rate (OR = 0.492; CI, 0.380-0.636) and mortality (OR=0.535; CI, 0.395-0.724). Endovascular aneurysm repair use is increasing for RAAA and is more common in urban teaching hospitals while NO therapy is more common in rural hospitals. Endovascular aneurysm repair is associated with reduced mortality and complications across all age groups. Efforts to reduce mortality from RAAA should concentrate on reducing NO and OSR in patients who are suitable for EVAR. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Safety and efficacy of transhepatic and transsplenic access for endovascular management of portal vein complications after liver transplantation.

    Science.gov (United States)

    Ohm, Joon-Young; Ko, Gi-Young; Sung, Kyu-Bo; Gwon, Dong-Il; Ko, Heung Kyu

    2017-09-01

    The purpose of this article is to evaluate and compare the safety and efficacy of endovascular management of the portal vein (PV) via percutaneous transsplenic access versus percutaneous transhepatic access in liver transplantation (LT) recipients. A total of 18 patients who underwent endovascular management of PV via percutaneous transhepatic (n = 8) and transsplenic (n = 10) access were enrolled. Transsplenic access was chosen if the spleen was located in a normal position, the splenic vein (SpV) was preserved, and the target lesion did not involve confluence of the superior mesenteric and SpVs. Accessibility of the percutaneous transsplenic puncture was confirmed via ultrasound (US) in the angiography suite. All procedures were performed under local anesthesia. Percutaneous transhepatic or transsplenic access was performed using a 21-gauge Chiba needle under US and fluoroscopic guidance, followed by balloon angioplasty, stent placement, or variceal embolization. The access tract was embolized using coils and a mixture (1:2) of glue and ethiodized oil. Transhepatic or transsplenic access was successfully achieved in all patients. A total of 12 patients underwent stent placement; 3 had balloon angioplasty only; 2 had variceal embolization only; and 1 had variceal embolization followed by successful stent placement. Regarding major complications, 1 patient experienced a SpV tear with extravasation during transsplenic balloon angioplasty, which was successfully managed using temporary balloon inflation, followed by transfusion. Clinical success was achieved in 9 of 11 (82%) patients who exhibited clinical manifestations. The remaining 7 patients who underwent prophylactic endovascular management were healthy. In conclusion, endovascular management of PV via percutaneous transsplenic access is a relatively safe and effective alternative that does not damage the liver grafts of LT recipients. Liver Transplantation 23 1133-1142 2017 AASLD. © 2017 by the American

  19. Current status of endovascular catheter robotics.

    Science.gov (United States)

    Lumsden, Alan B; Bismuth, Jean

    2018-06-01

    In this review, we will detail the evolution of endovascular therapy as the basis for the development of catheter-based robotics. In parallel, we will outline the evolution of robotics in the surgical space and how the convergence of technology and the entrepreneurs who push this evolution have led to the development of endovascular robots. The current state-of-the-art and future directions and potential are summarized for the reader. Information in this review has been drawn primarily from our personal clinical and preclinical experience in use of catheter robotics, coupled with some ground-breaking work reported from a few other major centers who have embraced the technology's capabilities and opportunities. Several case studies demonstrating the unique capabilities of a precisely controlled catheter are presented. Most of the preclinical work was performed in the advanced imaging and navigation laboratory. In this unique facility, the interface of advanced imaging techniques and robotic guidance is being explored. Although this procedure employs a very high-tech approach to navigation inside the endovascular space, we have conveyed the kind of opportunities that this technology affords to integrate 3D imaging and 3D control. Further, we present the opportunity of semi-autonomous motion of these devices to a target. For the interventionist, enhanced precision can be achieved in a nearly radiation-free environment.

  20. Endovascular treatment of intracranial venous sinus thrombosis

    International Nuclear Information System (INIS)

    Xu Shubin; Liang Zhihui; Cui Jinguo; Tian Huiqin; Li Liang; Chen Feng

    2009-01-01

    Objective: To evaluate the clinical efficacy and safety of endovascular treatment for intracranial venous sinus thrombosis. Methods: Ten patients with intracranial venous sinus thrombosis, confirmed by CT, MRI, MRV and / or DSA and encountered during the period of Aug. 2005-Aug. 2007, were treated with endovascular management after they failed to respond to anticoagulant therapy. Of ten patients, intravenous thrombolysis and mechanical thrombus maceration were carried out in 6, while intravenous thrombolysis, mechanical thrombus maceration together with intra-arterial thrombolysis were employed in 4. After the treatment, the anticoagulant therapy continued for 6 months. The patients were followed up for 12-29 months (mean 21 months). Results: After the treatment, the clinical symptoms and signs were completely or partially relieved in eight patients, including disappearance of headache (n=6) and relive of headache (n=2). No obvious improvement was found in one patient and linguistic function disturbance was seen in the remaining one. Lumbar puncture showed that the cerebrospinal fluid pressure returned to normal in all patients. Neither recurrence of thrombosis nor new symptom of neuralgic dysfunction was observed. No procedure-related intracranial or systemic hemorrhagic complications occurred both during and after the operation. Conclusion: Endovascular treatment is an effective and safe procedure for the potentially catastrophic intracranial venous thrombosis. (authors)

  1. Complications of endovascular treatment of cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Orrù, Emanuele, E-mail: surgeon.ema@gmail.com [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Roccatagliata, Luca, E-mail: lroccatagliata@neurologia.unige.it [Neuroradiology Department, IRCCS San Martino University Hospital and IST, Largo Rosanna Benzi 10, Genoa 16132 (Italy); Department of Health Sciences (DISSAL), University of Genoa (Italy); Cester, Giacomo, E-mail: giacomo.cester@sanita.padova.it [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Causin, Francesco, E-mail: francesco.causin@sanita.padova.it [Neuroradiology Department, Padua University Hospital, Via Giustiniani 2, Padua 35128 (Italy); Castellan, Lucio, E-mail: lucio.castellan@hsanmartino.it [Neuroradiology Department, IRCCS San Martino University Hospital and IST, Largo Rosanna Benzi 10, Genoa 16132 (Italy)

    2013-10-01

    The number of neuroendovascular treatments of both ruptured and unruptured aneurysms has increased substantially in the last two decades. Complications of endovascular treatments of cerebral aneurysms are rare but can potentially lead to acute worsening of the neurological status, to new neurological deficits or death. Some of the possible complications, such as vascular access site complications or systemic side effects associated with contrast medium (e.g. contrast medium allergy, contrast induced nephropathy) can also be encountered in diagnostic angiography. The most common complications of endovascular treatment of cerebral aneurysms are related to acute thromboembolic events and perforation of the aneurysm. Overall, the reported rate of thromboembolic complications ranges between 4.7% and 12.5% while the rate of intraprocedural rupture of cerebral aneurysms is about 0.7% in patients with unruptured aneurysms and about 4.1% in patients with previously ruptured aneurysms. Thromboembolic and hemorrhagic complications may occur during different phases of endovascular procedures and are related to different technical, clinical and anatomic reasons. A thorough knowledge of the different aspects of these complications can reduce the risk of their occurrence and minimize their clinical sequelae. A deep understanding of complications and of their management is thus part of the best standard of care.

  2. An unusual case of aortic rupture after deployment of a bare stent in the treatment of aortic dissection in a patient with giant-cell arteritis.

    Science.gov (United States)

    Rynio, Pawel; Kazimierczak, Arkadiusz; Gutowski, Piotr; Cnotliwy, Miloslaw

    2017-06-01

    Giant-cell arteritis is associated with a higher risk of aortic aneurysm and aortic dissection formation. We present a women with aortic dissection type B treated with a stent graft and bare-metal stent implantation. After the stent deployment we noticed aortic rupture, which was successfully treated with implantation of an additional stent graft. This report highlights the difficulty of endovascular therapy in patients with giant-cell arteritis. We have to bear in mind that chronic inflammation of the aorta leads to a more fragile aortic wall than normal. We recommend the use of a stent graft over a bare-metal stent and gentle use of a balloon catheter.

  3. Transjugular Endovascular Recanalization of Splenic Vein in Patients with Regional Portal Hypertension Complicated by Gastrointestinal Bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Xuefeng; Nie, Ling; Wang, Zhu; Tsauo, Jiaywei; Tang, Chengwei; Li, Xiao, E-mail: simonlixiao@126.com [West China Hospital, Sichuan University, Department of Gastroenterology (China)

    2013-05-02

    PurposeRegional portal hypertension (RPH) is an uncommon clinical syndrome resulting from splenic vein stenosis/occlusion, which may cause gastrointestinal (GI) bleeding from the esophagogastric varices. The present study evaluated the safety and efficacy of transjugular endovascular recanalization of splenic vein in patients with GI bleeding secondary to RPH.MethodsFrom December 2008 to May 2011, 11 patients who were diagnosed with RPH complicated by GI bleeding and had undergone transjugular endovascular recanalization of splenic vein were reviewed retrospectively. Contrast-enhanced computed tomography revealed splenic vein stenosis in six cases and splenic vein occlusion in five. Etiology of RPH was chronic pancreatitis (n = 7), acute pancreatitis with pancreatic pseudocyst (n = 2), pancreatic injury (n = 1), and isolated pancreatic tuberculosis (n = 1).ResultsTechnical success was achieved in 8 of 11 patients via the transjugular approach, including six patients with splenic vein stenosis and two patients with splenic vein occlusion. Two patients underwent splenic vein venoplasty only, whereas four patients underwent bare stents deployment and two covered stents. Splenic vein pressure gradient (SPG) was reduced from 21.5 ± 7.3 to 2.9 ± 1.4 mmHg after the procedure (P < 0.01). For the remaining three patients who had technical failures, splenic artery embolization and subsequent splenectomy was performed. During a median follow-up time of 17.5 (range, 3–34) months, no recurrence of GI bleeding was observed.ConclusionsTransjugular endovascular recanalization of splenic vein is a safe and effective therapeutic option in patients with RPH complicated by GI bleeding and is not associated with an increased risk of procedure-related complications.

  4. Transjugular Endovascular Recanalization of Splenic Vein in Patients with Regional Portal Hypertension Complicated by Gastrointestinal Bleeding

    International Nuclear Information System (INIS)

    Luo, Xuefeng; Nie, Ling; Wang, Zhu; Tsauo, Jiaywei; Tang, Chengwei; Li, Xiao

    2014-01-01

    PurposeRegional portal hypertension (RPH) is an uncommon clinical syndrome resulting from splenic vein stenosis/occlusion, which may cause gastrointestinal (GI) bleeding from the esophagogastric varices. The present study evaluated the safety and efficacy of transjugular endovascular recanalization of splenic vein in patients with GI bleeding secondary to RPH.MethodsFrom December 2008 to May 2011, 11 patients who were diagnosed with RPH complicated by GI bleeding and had undergone transjugular endovascular recanalization of splenic vein were reviewed retrospectively. Contrast-enhanced computed tomography revealed splenic vein stenosis in six cases and splenic vein occlusion in five. Etiology of RPH was chronic pancreatitis (n = 7), acute pancreatitis with pancreatic pseudocyst (n = 2), pancreatic injury (n = 1), and isolated pancreatic tuberculosis (n = 1).ResultsTechnical success was achieved in 8 of 11 patients via the transjugular approach, including six patients with splenic vein stenosis and two patients with splenic vein occlusion. Two patients underwent splenic vein venoplasty only, whereas four patients underwent bare stents deployment and two covered stents. Splenic vein pressure gradient (SPG) was reduced from 21.5 ± 7.3 to 2.9 ± 1.4 mmHg after the procedure (P < 0.01). For the remaining three patients who had technical failures, splenic artery embolization and subsequent splenectomy was performed. During a median follow-up time of 17.5 (range, 3–34) months, no recurrence of GI bleeding was observed.ConclusionsTransjugular endovascular recanalization of splenic vein is a safe and effective therapeutic option in patients with RPH complicated by GI bleeding and is not associated with an increased risk of procedure-related complications

  5. Endovascular treatment of cerebral aneurysms - a cost analysis | Le ...

    African Journals Online (AJOL)

    The average cost for endovascular treatment per patient was R37 041. Surgical treatment was more expensive at R44 104, a difference of 16%. Conclusions. Despite the high cost of endovascular devices, appropriate use of this technology ultimately offers less expensive treatment than microsurgical clipping of aneurysms.

  6. Current role of endovascular therapy in Marfan patients with previous aortic surgery

    Directory of Open Access Journals (Sweden)

    Ibrahim Akin

    2008-02-01

    Full Text Available Ibrahim Akin, Stephan Kische, Tim C Rehders, Tushar Chatterjee, Henrik Schneider, Thomas Körber, Christoph A Nienaber, Hüseyin InceDepartment of Medicine, Division of Cardiology at the University Hospital Rostock, Rostock School of Medicine, Ernst-Heydemann-Str. 6, 18057 Rostock, GermanyAbstract: The Marfan syndrome is a heritable disorder of the connective tissue which affects the cardiovascular, ocular, and skeletal system. The cardiovascular manifestation with aortic root dilatation, aortic valve regurgitation, and aortic dissection has a prevalence of 60% to 90% and determines the premature death of these patients. Thirty-four percent of the patients with Marfan syndrome will have serious cardiovascular complications requiring surgery in the first 10 years after diagnosis. Before aortic surgery became available, the majority of the patients died by the age of 32 years. Introduction in the aortic surgery techniques caused an increase of the 10 year survival rate up to 97%. The purpose of this article is to give an overview about the feasibility and outcome of stent-graft placement in the descending thoracic aorta in Marfan patients with previous aortic surgery.Keywords: Marfan syndrome, aortic dissection, root replacement, stent-graft, previous aortic surgery

  7. Simulation and augmented reality in endovascular neurosurgery: lessons from aviation.

    Science.gov (United States)

    Mitha, Alim P; Almekhlafi, Mohammed A; Janjua, Major Jameel J; Albuquerque, Felipe C; McDougall, Cameron G

    2013-01-01

    Endovascular neurosurgery is a discipline strongly dependent on imaging. Therefore, technology that improves how much useful information we can garner from a single image has the potential to dramatically assist decision making during endovascular procedures. Furthermore, education in an image-enhanced environment, especially with the incorporation of simulation, can improve the safety of the procedures and give interventionalists and trainees the opportunity to study or perform simulated procedures before the intervention, much like what is practiced in the field of aviation. Here, we examine the use of simulators in the training of fighter pilots and discuss how similar benefits can compensate for current deficiencies in endovascular training. We describe the types of simulation used for endovascular procedures, including virtual reality, and discuss the relevant data on its utility in training. Finally, the benefit of augmented reality during endovascular procedures is discussed, along with future computerized image enhancement techniques.

  8. Improvement in Visual Symptomatology after Endovascular Treatment of Cavernous Carotid Aneurysms: A Multicenter Study.

    Science.gov (United States)

    Drazin, Doniel; Choulakian, Armen; Nuño, Miriam; Gandhi, Ravi; Edgell, Randall C; Alexander, Michael J

    2013-06-01

    Aneurysms arising from the cavernous internal carotid artery (CCAs) pose technical challenges for surgical management and such patients are frequently referred for endovascular treatment. These aneurysms often produce a variety of neurological deficits, primarily those related to oculoparesis. Our purpose was to determine the visual and neurological outcome of patients with treated CCAs. We reviewed the medical records and angiograms for patients who underwent endovascular treatment for CCAs at three academic medical centers. The following outcomes were analyzed: angiographic assessment, visual improvement and outcome at 3 months using Glasgow Outcome Scale (GOS). Thirty-four patients (mean age 54.7 years) were treated for CCAs. The mean aneurysm size was 14.2 mm (range: 3-45 mm), and fourteen patients (41.2%) required stent assistance. Twenty-one aneurysms (61.8%) were completely occluded; nine aneurysms (26.6%) had near-complete occlusion; 4 aneurysms (11.8%) had partial occlusion. Seven patients (20.6%) required retreatment. Fifteen of the 34 patients (44.1%) presented with visual symptoms, while only eight patients had residual visual symptomatology at follow-up (44.1% vs. 23.5%; p=0.02). Patients that presented with visual symptoms (N=15) had a mean aneurysm size of 24.5 mm, while those without visual symptoms (N=19) had a size of 7.5 mm (p=0.001). Follow-up GOS was good (4-5) in 29 patients (90.6%). No thromboembolic complications were observed. One patient died (3.1%) of an unrelated cause. Most patients in this multicenter series improved or remained stable after treatment. The results of this study indicate that endovascular treatment may improve the outcome of visual symptoms in patients with large cavernous aneurysms with low periprocedural morbidity. MJA is a consultant for Stryker and Codman. AC receives a Cordis Endovascular Fellowship Training Grant and a Stryker Endovascular Neurosurgery Post-graduate Fellow Grant. Dr. Drazin: Conception and Design

  9. Comparison of Total Arch and Partial Arch Transposition During Hybrid Endovascular Repair for Aortic Arch Disease.

    Science.gov (United States)

    Kang, W C; Ko, Y-G; Oh, P C; Shin, E K; Park, C-H; Choi, D; Youn, Y N; Lee, D Y

    2016-08-01

    Total arch transposition (TAT) during hybrid endovascular repair for aortic arch disease is believed to allow a better landing zone, but also to be associated with higher peri-operative mortality than partial arch transposition (PAT). Information on this issue is limited. This study was a retrospective analysis. All 53 consecutive patients with aortic arch disease (41 males, mean age 65.0 years) who underwent hybrid endovascular repair with TAT (zone 0, n=20) or PAT (zone 1 or 2, n=33) from 2008 to 2014 were analyzed retrospectively. The peri-operative and late outcomes of these two groups were compared. Baseline characteristics, including EuroSCORE II results, were similar in the two groups. After procedures, peri-operative mortalities and stroke rates were similar in the two groups (5.0% vs. 9.1%, p=1.000, and 10.0% vs. 6.1%, p=.627). Interestingly, all four strokes occurred in patients with a type III aortic arch irrespective of transposition type. Primary success rates (80.0% vs. 69.7%, p=.527) and type I endoleak incidences (20.0% vs. 27.3%, p=.744) were not significantly different. During follow up (mean duration 36.9 months), overall survival (89.7% vs. 87.4% at 1 year and 89.7% vs. 79.3% at 3 years; p=.375) and re-intervention free survival rates (78.6% vs. 92.0% at 1 year; 72.0% vs. 62.2% at 3 years, p=.872) were similar in the two groups. Morbidity and mortality were high within the first year of hybrid endovascular therapy for aortic arch disease, implying that candidates for hybrid procedures need to be selected carefully. Hybrid endovascular repair with TAT was found to have peri-operative mortality, stroke, and long-term survival rates comparable with PAT, so hybrid endovascular repair may be considered, irrespective of type of arch reconstruction, when clinically indicated. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Covered stents for endovascular repair of iatrogenic injuries of iliac and femoral arteries

    Energy Technology Data Exchange (ETDEWEB)

    Kufner, Sebastian, E-mail: kufners@dhm.mhn.de [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Cassese, Salvatore; Groha, Philipp; Byrne, Robert A. [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); Schunkert, Heribert; Kastrati, Adnan [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany); DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich (Germany); Ott, Ilka; Fusaro, Massimiliano [Deutsches Herzzentrum München, Technische Universität München, Munich (Germany)

    2015-04-15

    Background: The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. A strategy of percutaneous transluminal angioplasty (PTA) with covered stent (CS) may represent a valuable alternative to open surgery. However, systematic evaluations of CS in this setting represent a scientific gap. In the present study, we investigate the procedural and clinical outcomes associated with PTA and CS implantation to repair iatrogenic injuries of peripheral arteries. Methods: All patients undergoing PTA with CS for endovascular repair of iatrogenic injuries of peripheral arteries between August 2010 and July 2013 at our Institution were retrospectively analyzed. The primary endpoint was the technical success. Secondary endpoints were in-hospital mortality and cumulative death, target lesion revascularization (TLR), amputation and major stroke at 12-month follow-up. Results: During the period of observation, a total of 30 patients underwent PTA with either self-expandable (43.3%) or balloon-expandable CS (56.7%) for iatrogenic injuries of peripheral arteries. Injuries consisted of perforation/rupture (76.7%), arteriovenous fistula (16.7%) and pseudoaneurysm (6.7%) of iliac–femoral arteries. Technical success was achieved in all cases. Median follow-up was 409 days [210–907]. The incidence of in-hospital mortality was 10.0%. At 12-month follow-up, the incidence of death, TLR, amputation and major stroke was 20.0%, 17.0%, 3.3% and 6.7%, respectively. Conclusion: The use of covered stents for endovascular repair of iatrogenic injuries of peripheral arteries shows a high technical success and may be alternative to surgery. Further studies with larger populations are needed to confirm these preliminary findings. - Highlights: • The growing number of complex endovascular procedures is expected to increase the risk of iatrogenic injuries of peripheral arteries. • Percutaneous transluminal angioplasty with

  11. Geometric Deformations of the Thoracic Aorta and Supra-Aortic Arch Branch Vessels Following Thoracic Endovascular Aortic Repair.

    Science.gov (United States)

    Ullery, Brant W; Suh, Ga-Young; Hirotsu, Kelsey; Zhu, David; Lee, Jason T; Dake, Michael D; Fleischmann, Dominik; Cheng, Christopher P

    2018-04-01

    To utilize 3-D modeling techniques to better characterize geometric deformations of the supra-aortic arch branch vessels and descending thoracic aorta after thoracic endovascular aortic repair. Eighteen patients underwent endovascular repair of either type B aortic dissection (n = 10) or thoracic aortic aneurysm (n = 8). Computed tomography angiography was obtained pre- and postprocedure, and 3-D geometric models of the aorta and supra-aortic branch vessels were constructed. Branch angle of the supra-aortic branch vessels and curvature metrics of the ascending aorta, aortic arch, and stented thoracic aortic lumen were calculated both at pre- and postintervention. The left common carotid artery branch angle was lower than the left subclavian artery angles preintervention ( P Supra-aortic branch vessel angulation remains relatively static when proximal landing zones are distal to the left common carotid artery.

  12. Long-term success of endovascular treatment of benign superior vena cava occlusion with chylothorax and chylopericardium

    Energy Technology Data Exchange (ETDEWEB)

    Veroux, Pierfrancesco; Veroux, Massimiliano; Bonanno, Maria Giovanna; Tumminelli, Maria Giuseppina [Department of Surgery and Transplantation, University Hospital, Via S. Sofia, 78, 95123 Catania (Italy); Baggio, Elda [Department of Surgery and Gastroenterological Sciences, University Hospital of Verona (Italy); Petrillo, Giuseppe [Department of Radiology, University Hospital, Via S. Sofia, 78, 95123 Catania (Italy)

    2002-07-01

    The most likely etiology of benign obstruction of the superior vena cava (SVC) include fibrosing mediastinitis and iatrogenic etiologies such as sclerosis and obstruction caused by pacemakers and central venous catheter. Percutaneous stenting of SVC has been used with success both in malignant and benign superior vena cava syndrome; however, long-term follow-up of endovascular procedures is not well known. We present a case of a patient with complete occlusion of SVC of benign etiology, presenting dramatically with bilateral chylothorax and chylopericardium with cardiac tamponade, who underwent successful vena caval revascularization with thrombolytic therapy and placement of self-expanding metallic stent. The 42-month follow-up could encourage endovascular procedures even in SVC syndrome of benign etiology. (orig.)

  13. Flow and wall shear stress characterization following endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model

    NARCIS (Netherlands)

    Boersen, Johannes T.; Groot Jebbink, Erik; Versluis, Michel; Slump, Cornelis H.; Ku, David N.; de Vries, Jean-Paul P.M.; Reijnen, Michel M.P.J.

    2017-01-01

    Background Endovascular aneurysm repair (EVAR) with a modular endograft has become the preferred treatment for abdominal aortic aneurysms. A novel concept is endovascular aneurysm sealing (EVAS), consisting of dual endoframes surrounded by polymer-filled endobags. This dual-lumen configuration is

  14. Post procedure headache in patients treated for neurovascular arteriovenous malformations and aneurysms using endovascular therapy

    DEFF Research Database (Denmark)

    Khan, Sabrina; Amin, Faisal Mohammad; Hauerberg, John

    2016-01-01

    BACKGROUND: Though endovascular therapy (EVT) is increasingly applied in the treatment of intracranial vascular lesions, little is known about the effect of EVT on post-procedure headache. We aimed to investigate the prevalence of headache in patients who have undergone EVT for cerebral...... arteriovenous malformations (AVMs) and aneurysms. METHODS: A total of 324 patients underwent EVT treatment for aneurysms and AVMs at the Danish National Hospital from January 2012 to December 2014. We applied strict exclusion criteria in order to minimize the effect of other factors on headache occurrence, e.......g., craniotomy. Eligible subjects were phone-interviewed using a purpose-developed semi-structured questionnaire. Headaches were classified according to ICHD-III beta criteria. RESULTS: The 59 patients underwent treatment of aneurysms (n = 43), cranial dural fistulas (n = 11), and AVMs (n = 5...

  15. Preop endovascular embolization in juvenile nasal angiofibroma management

    Directory of Open Access Journals (Sweden)

    M. V. Nersesyan

    2018-01-01

    Full Text Available Introduction. Juvenile nasal angiofibroma (JNA is an aggressively expanding fibro-vascular benign tumor, which occurs in male adolescents. Surgical management of JNA is considered as one of the most difficult in rhinology, because it very often has accompanied with profuse, streaming bleeding. Endovascular embolization has successfully used for reducing the operative blood loss since 2000th. Nevertheless, there is no consensus in the literature about its expediently using because of complications, which may occur.Objective is to evaluate the effectiveness of selective angiography and endovascular embolization in reducing bleeding when removal of JNA of different stages.Materials and methods. In the N.N. Burdenko National Medical Research Center of Neurosurgery 134 patients with JNA had been treated surgically.Results. 110 patients with JNA, who underwent embolization, managed to perform total, subtotal or partial devascularization of the tumor. Total devascularization was achieved in JNA blood supply variant only from the external carotid artery (ECA system from 1 or 2 sides  (in primary patients or in patients who had not previously been embolized (n = 39; subtotal devascularization, if the blood supply was carried out from the ECA system, internal carotid artery (ICA on the 1 side (n = 52 and partial, if there was blood supply from the ECA and significant from the ICA system from 2 sides (in patients with relapse after previous embolization with microspirals or the ECA ligations from 1 or 2 sides, as well as with giant JNA (n = 19. Since the vast majority of patients admitted to our clinic were previously operated on, and JNA blood supply in relapses was more pronounced, we performed the comparison of the degree of tumor devascularization depending on its blood supply in primary patients and patients with relapse. It turned out, as could be expected, that with the primary JNA often managed  to execute a total devascularization than with JNA

  16. Endovascular Management of Patients with Head and Neck Cancers Presenting with Acute Hemorrhage: A Single-Center Retrospective Study

    Energy Technology Data Exchange (ETDEWEB)

    Vilas Boas, P. P.; Castro-Afonso, L. H. de; Monsignore, L. M.; Nakiri, G. S. [University of São Paulo, Division of Interventional Neuroradiology, Ribeirão Preto Medical School (Brazil); Mello-Filho, F. V. de [University of São Paulo, Department of Ophthalmology, Otorhinolaryngology and Head and Neck Surgery, Ribeirão Preto Medical School (Brazil); Abud, D. G., E-mail: dgabud@fmrp.usp.br [University of São Paulo, Division of Interventional Neuroradiology, Ribeirão Preto Medical School (Brazil)

    2017-04-15

    PurposeAcute hemorrhage associated with cancers of the head and neck is a life-threatening condition that requires immediate action. The aim of this study was to assess the safety and efficacy of endovascular embolization for acute hemorrhage in patients with head and neck cancers.Materials and MethodsData were retrospectively collected from patients with head and neck cancers who underwent endovascular embolization to treat acute hemorrhage. The primary endpoint was the rate of immediate control of hemorrhage during the first 24 h after embolization. The secondary endpoints were technical or clinical complications, rate of re-hemorrhage 24 h after the procedure, time from embolization to re-hemorrhage, hospitalization time, mortality rate, and time from embolization to death.ResultsFifty-one patients underwent endovascular embolization. The primary endpoint was achieved in 94% of patients. The rate of technical complications was 5.8%, and no clinical complication was observed. Twelve patients (23.5%) had hemorrhage recurrence after an average time of 127.5 days. The average hospitalization time was 7.4 days, the mortality rate during the follow-up period was 66.6%, and the average time from embolization to death was 132.5 days.ConclusionEndovascular embolization to treat acute hemorrhage in patients with head and neck cancers is a safe and effective method for the immediate control of hemorrhage and results in a high rate of hemorrhage control. Larger studies are necessary to determine which treatment strategy is best for improving patient outcomes.

  17. Endovascular treatment of type B dissection in patients with Marfan syndrome: mid-term outcomes and aortic remodeling.

    Science.gov (United States)

    Eid-Lidt, Guering; Gaspar, Jorge; Meléndez-Ramírez, Gabriela; Cervantes S, Jorge; González-Pacheco, Hector; Dámas de Los Santos, Félix; Meave-González, Aloha; Ramírez Marroquín, Samuel

    2013-12-01

    To evaluate the mid-term outcomes, and the aortic remodeling in Marfan syndrome (MFS) patients with type B dissection that were treated with endovascular repair. MFS is a relative contraindication to thoracic endovascular aortic repair (TEVAR). Mid-term aortic outcomes data in MFS after TEVAR are limited, and the occurrence of late events remains unclear. Of 89 patients that underwent TEVAR between September 2002 and February 2011, 10 patients with mid-term follow-up fulfilled the Ghent criteria for MFS and complicated type B dissection. High risk for open surgery was documented in 90%. The mean age was 35.1 ± 9.4 years and all patients presented with acute aortic syndrome complicating a chronic type B dissection (DeBakey type IIIb). Five patients underwent a Bentall surgical procedure previous to endovascular repair, and in four patients initial TEVAR was followed by surgery of the ascending aorta. Treatment was limited to endovascular repair in only one patient. In-hospital mortality was 10%. At a mean follow-up of 59.6 ± 38.9 months, the cumulated mortality was of 20% and late mortality 11.1%. The rate of secondary endoleak was 44.4%, and late reintervention of 33.3%. Survival freedom from cardiovascular death at 8 years was 80.0%, and positive remodeling was documented in 37.5% of patients. Our results suggest that TEVAR is feasible, safe, and associated with a high reintervention rate and reduced rate of positive aortic remodeling in patients with Marfan syndrome. Survival at 8 years was comparable to contemporary series of open repair. Copyright © 2013 Wiley Periodicals, Inc.

  18. Endovascular Management of Patients with Head and Neck Cancers Presenting with Acute Hemorrhage: A Single-Center Retrospective Study

    International Nuclear Information System (INIS)

    Vilas Boas, P. P.; Castro-Afonso, L. H. de; Monsignore, L. M.; Nakiri, G. S.; Mello-Filho, F. V. de; Abud, D. G.

    2017-01-01

    PurposeAcute hemorrhage associated with cancers of the head and neck is a life-threatening condition that requires immediate action. The aim of this study was to assess the safety and efficacy of endovascular embolization for acute hemorrhage in patients with head and neck cancers.Materials and MethodsData were retrospectively collected from patients with head and neck cancers who underwent endovascular embolization to treat acute hemorrhage. The primary endpoint was the rate of immediate control of hemorrhage during the first 24 h after embolization. The secondary endpoints were technical or clinical complications, rate of re-hemorrhage 24 h after the procedure, time from embolization to re-hemorrhage, hospitalization time, mortality rate, and time from embolization to death.ResultsFifty-one patients underwent endovascular embolization. The primary endpoint was achieved in 94% of patients. The rate of technical complications was 5.8%, and no clinical complication was observed. Twelve patients (23.5%) had hemorrhage recurrence after an average time of 127.5 days. The average hospitalization time was 7.4 days, the mortality rate during the follow-up period was 66.6%, and the average time from embolization to death was 132.5 days.ConclusionEndovascular embolization to treat acute hemorrhage in patients with head and neck cancers is a safe and effective method for the immediate control of hemorrhage and results in a high rate of hemorrhage control. Larger studies are necessary to determine which treatment strategy is best for improving patient outcomes.

  19. de novo'' aneurysms following endovascular procedures

    International Nuclear Information System (INIS)

    Briganti, F.; Cirillo, S.; Caranci, F.; Esposito, F.; Maiuri, F.

    2002-01-01

    Two personal cases of ''de novo'' aneurysms of the anterior communicating artery (ACoA) occurring 9 and 4 years, respectively, after endovascular carotid occlusion are described. A review of the 30 reported cases (including our own two) of ''de novo'' aneurysms after occlusion of the major cerebral vessels has shown some features, including a rather long time interval after the endovascular procedure of up to 20-25 years (average 9.6 years), a preferential ACoA (36.3%) and internal carotid artery-posterior communicating artery (ICA-PCoA) (33.3%) location of the ''de novo'' aneurysms, and a 10% rate of multiple aneurysms. These data are compared with those of the group of reported spontaneous ''de novo'' aneurysms after SAH or previous aneurysm clipping. We agree that the frequency of ''de novo'' aneurysms after major-vessel occlusion (two among ten procedures in our series, or 20%) is higher than commonly reported (0 to 11%). For this reason, we suggest that patients who have been submitted to endovascular major-vessel occlusion be followed up for up to 20-25 years after the procedure, using non-invasive imaging studies such as MR angiography and high-resolution CT angiography. On the other hand, periodic digital angiography has a questionable risk-benefit ratio; it may be used when a ''de novo'' aneurysm is detected or suspected on non-invasive studies. The progressive enlargement of the ACoA after carotid occlusion, as described in our case 1, must be considered a radiological finding of risk for ''de novo'' aneurysm formation. (orig.)

  20. Endovascular treatment of stroke. When and How?

    International Nuclear Information System (INIS)

    Mantatzis, M.

    2012-01-01

    Full text: It is well known that stroke is the third leading cause of death and the most common cause of permanent disability in the Western countries. Ischemic stroke is the commonest between the causes and atheroembolic events is principally involved. Intravenous thrombolysis (IVT) has dramatically changed the treatment mentality which previously was mostly supportive and didn't change significantly the prognosis. IVT is now considered the standard of care, having however certain limitations that have paved the way for the development of endovascular treatment. The main disadvantage of IVT is the relatively limited available time window, leading very few patients to receive the treatment. Intra-arterial options for treatment are not confined to delivery of a thrombolytic drug into the thrombus, but extended to quite variable mechanical options. The use of thrombolytic agents regionally or locally (Intra-arterial Thrombolysis - IAT), although may be allowed for an extended time window comparatively to IVT, has more or less the same disadvantages and the complications that related to the administrated drug. Moreover and despite the good results of several randomized trials, IAT has never granted an FDA approval. Nevertheless its use is included in the AHA/ASA guidelines under recommended in certain situations. IAT can be used as a standalone treatment or may be combined (bridging therapy) with IVT. Endovascular treatment has been boosted however, after the advent of mechanical devices for clot removal in acute stroke. These devices have become more sophisticated nowadays and this treatment is more and more is preferred when endovascular means are considered. Initially, mechanical devices were used for the clot disruption in combination with IAT (augmented thrombolysis). Other devices have been developed aiming to directly remove a clot rather than disrupt or macerate it, and the procedure turned to be a thrombectomy. Many different devices had been used with

  1. Stroke prevention by endovascular treatment of carotid and vertebral artery dissections.

    Science.gov (United States)

    Moon, Karam; Albuquerque, Felipe C; Cole, Tyler; Gross, Bradley A; McDougall, Cameron G

    2017-10-01

    Endovascular intervention for cervical carotid artery dissection (CAD) and vertebral artery dissection (VAD) may be indicated in specific circumstances. To review our institutional experience with endovascular treatment of cervical dissections over the past 20 years to examine indications for treatment, interventional methods, and outcomes. Retrospective review of a prospectively maintained database to identify patients with extracranial dissection who underwent endovascular intervention between January 1996 and January 2016. Demographic data and details of procedures, outcomes, and complications were extracted. Of 116 patients [93 CAD, 23 VAD; mean age 44.9 years (range 5-76 years)], 104 underwent stent placement; 11, coil occlusion of the parent artery; and 1, stenting with contralateral vessel occlusion. The cohorts were well matched for age, sex, dissection etiology, and admission and follow-up modified Rankin Scale (mRS) scores. Patients with CAD had significantly more stent placements (p<0.001), failure of medical therapy (p=0.004), and interventions for enlarging pseudoaneurysms (p=0.01) or thromboembolic events (p=0.004). Patients with VAD had significantly more interventions for traumatic occlusion with recanalization (p<0.001). Dissections were spontaneous (n=67), traumatic (n=36), or iatrogenic (n=13). Traumatic dissections in patients with CAD were associated with poor admission mRS scores (p=0.01). Six of 67 (9.0%) patients with spontaneous dissection reported recent chiropractic manipulation. Mean follow-up was 3.5 years (range 1-146 months). Permanent morbidity/mortality was 3.4%, including two deaths. Over a follow-up period of 364 patient-years, 1 stroke occurred (0.27% per year). At last follow-up, 41 previously disabled patients [CAD, 31/93 (33.3%); VAD, 10/23 (43.5%)] were no longer disabled; no patient reported worsened disability. Patients with CAD and VAD differ significantly in presentation, indications for treatment, and treatment

  2. Outcomes of infrageniculate retrograde versus transfemoral access for endovascular intervention for chronic lower extremity ischemia.

    Science.gov (United States)

    Taha, Ashraf G; Abou Ali, Adham N; Al-Khoury, George; Singh, Michael J; Makaroun, Michel S; Avgerinos, Efthymios D; Chaer, Rabih A

    2018-03-31

    Retrograde infrageniculate access is an alternative treatment strategy for patients who have failed to respond to antegrade endovascular intervention. This study compares the outcomes of infrageniculate retrograde arterial access with the conventional transfemoral access for the endovascular management of chronic lower extremity ischemia. This was a retrospective single-center review of retrograde endovascular intervention (REI) from 2012 to 2016. Indications for intervention, comorbidities, complications, procedural success, limb outcomes, and mortality were analyzed. Technical failure was defined as the inability to complete the procedure because of failed access or unsuccessful recanalization. Infrageniculate access and transfemoral access were obtained with ultrasound or angiographic roadmap guidance. Patency rates were calculated for technically successful interventions. There were 47 patients (85% presenting with critical limb ischemia) who underwent sheathless REI after failed antegrade recanalization of TransAtlantic Inter-Society Consensus class D infrainguinal lesions, whereas 93 patients (83% with critical limb ischemia) underwent standard transfemoral access. There were 16 (34%) femoropopliteal, 14 (30%) tibial, and 17 (36%) multilevel interventions in the retrograde group compared with 41 (41%) femoropopliteal, 20 (20%) tibial, and 39 (39%) multilevel interventions in the transfemoral group. Access sites for the retrograde group included the dorsalis pedis (26%), midcalf peroneal (24%), anterior tibial (22%), posterior tibial (26%), and popliteal (2%) arteries. Overall technical success was achieved in 57% of the retrograde group compared with 78% of the transfemoral group. Mean follow-up was 20 months (range, 1-45 months). There were no significant differences in the primary patency rates between the two groups at 1 year and 2 years. The primary assisted patency rates were significantly better in the transfemoral group at 1 year (66% vs 46%; P

  3. Endovascular brachytherapy to prevent restenosis after angioplasty

    International Nuclear Information System (INIS)

    Wohlgemuth, W.A.; Bohndorf, K.

    2003-01-01

    Endovascular radiotherapy is the first effective prophylaxis of restenosis after percutaneous transluminal angioplasty (PTA) and stenting. The FDA recently approved two devices for the delivery of intracoronary radiation following coronary artery stenting. Published multicenter, double-blind, randomized trials of intracoronary radiation therapy report good results for preventing in-stent restenosis, while the data for the peripheral circulation are still inconclusive. Beta-emitters are easier applicable and probably also safer, whereas gamma-emitters have been more extensively evaluated clinically so far. Primary indication for endovascular brachytherapy are patients at high risk for restenosis, such as previous restenoses, in-stent hyperplasia, long stented segment, long PTA lesion, narrow residual vascular lumen and diabetes. Data from coronary circulation suggest a safety margin of at least 4 to 10 mm at both ends of the angioplastic segment to avoid edge restenosis. To prevent late thrombosis of the treated coronary segment, antiplatelet therapy with clopidogrel and aspirin are recommended for at least 6 months after PTA and for 12 months after a newly implanted stent. An established medication regimen after radiotherapy of peripheral arteries is still lacking. (orig.) [de

  4. Endovascular strategy for unruptured cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Mangiafico, S., E-mail: mangiax@libero.it [Interventional Neuroradiology Unit, Careggi University Hospital, Florence (Italy); Guarnieri, G., E-mail: gianluigiguarnieri@hotmail.it [Neuroradiology Service, Cardarelli Hospital, Naples (Italy); Consoli, A., E-mail: onemed21@gmail.com [Interventional Neuroradiology Unit, Careggi University Hospital, Florence (Italy); Ambrosanio, G., E-mail: gambros@libero.it [Neuroradiology Service, Cardarelli Hospital, Naples (Italy); Muto, M., E-mail: mutomar@tiscali.it [Neuroradiology Service, Cardarelli Hospital, Naples (Italy)

    2013-10-01

    The treatment of unruptured intracranial aneurysms (UIAs) remains complex and not clearly defined. While for ruptured intracranial aneurysms the management and the treatment option (surgery or endovascular treatment) are well defined by several trials, for asymptomatic UIAs the best management is still currently uncertain. The rationale to treat an UIA is to prevent the rupture and its consequent SAH and all complications derived from hemorrhage or reduce/eliminate neurological palsy. Although this statement is correct, the indication to treat an UIA should be based on a correct balance between the natural history of UIA and treatment risk. Patient's clinical history, aneurysm characteristics, and strategy management influence the natural history of UIAs and treatment outcomes. In the last 10 years and more, two important large multicenter studies were performed in order to analysis of all these factors and to evaluate the best treatment option for UIAs. The aim of this paper is to try to synthesize the possible indications to the endovascular treatment (EVT), when and how to treat an UIA.

  5. Endovascular Management of Central Retinal Arterial Occlusion.

    Science.gov (United States)

    Agarwal, Nitin; Gala, Nihar B; Baumrind, Benjamin; Hansberry, David R; Thabet, Ahmad M; Gandhi, Chirag D; Prestigiacomo, Charles J

    2016-11-01

    Central retinal artery occlusion (CRAO) is an ophthalmologic emergency due to the sudden cessation of circulation to the inner retinal layer. Without immediate treatment, permanent blindness may ensue. Several treatment options exist, ranging from noninvasive medical management to thrombolysis. Nonetheless, ongoing debate exists regarding the best therapeutic strategy. The authors present the case of a 78-year-old woman with a medical history of hypercholesterolemia and rheumatoid arthritis who experienced complete loss of vision in her left eye. Following ophthalmologic evaluation demonstrating left CRAO, anterior chamber paracentesis was performed. Endovascular intervention was performed via local intra-arterial fibrinolysis with alteplase. Her vision returned to 20/20 following the procedure. In general, conventional therapies have not significantly improved patient outcomes. Several management options exist for CRAO. In general, conservative measures have not been reported to yield better patient outcomes as compared to the natural history of this medical emergency. Endovascular approaches are another option as observed with this case reported. In cases of CRAO, therapeutic strategies such as intra-arterial fibrinolysis utilize a local infusion of reactive tissue plasminogen activator directly at the site of occlusion via catheterization of the ophthalmic artery. Although several case series do show promising results after treating CRAO with intra-arterial fibrinolysis, further studies are required given the reports of complications.

  6. Endovascular therapeutic strategies in ruptured intracranial aneurysms

    International Nuclear Information System (INIS)

    Machi, Paolo; Lobotesis, Kyriakos; Vendrell, Jean Francoise; Riquelme, Carlos; Eker, Omer; Costalat, Vincent; Bonafe, Alain

    2013-01-01

    The aim of the present study was to evaluate endovascular techniques used currently which were not available at the time of ISAT inclusion period, such as balloon remodelling and flow-divertion, in order to assess whether these new technologies have improved the endovascular approach outcomes. We present a review of articles, published in major journals, with the aim to evaluate the efficacy and the safety of coiling with balloon remodelling for the treatment of ruptured aneurysms in comparison to coiling performed without such coadjutant techniques. Furthermore, we reviewed publications reporting on the treatment of ruptured aneurysms in the acute phase with the one of the most recent technologies available nowadays: the flow diverting stent. Looking at the recent literature the results regarding ruptured aneurysms treated with balloon assisted coiling (BAC) have shown an improvement in terms of anatomical results and morbi-mortality rates. Case series of ruptured middle cerebral artery (MCA) aneurysms treated by EVT report results similar to those obtained by surgical clipping. Several articles recently report encouraging results in treating ruptured dissecting and blister aneurysms with flow diverters. Questions regarding the best treatment available for ruptured aneurysms are yet to be answered. Hence there is a need for a subsequent trial aiming to answer these unresolved issues

  7. Endovascular Interventions for the Morbidly Adherent Placenta

    Directory of Open Access Journals (Sweden)

    Claire Kaufman

    2018-05-01

    Full Text Available Morbidly adherent placentas are a spectrum of abnormalities ranging from placental invasion of the myometrium to invasion past the myometrium and muscular layers into adjacent structures. This entity is becoming more prevalent recently with increased number of cesarean deliveries. Given the high risk of morbidity and mortality, this was traditionally treated with pre-term planned cesarean hysterectomy. However, recently, uterine preservation techniques have been implemented for those women wishing to preserve future fertility or their uterus. Early identification is crucial as studies have shown better outcomes for women treated at tertiary care facilities by a dedicated multidisciplinary team. Interventional radiologists are frequently included in the care of these patients as there are several different endovascular techniques which can be implemented to decrease morbidity in these patients both in conjunction with cesarean hysterectomy and in the setting of uterine preservation. This article will review the spectrum of morbidly adherent placentas, imaging, as well as the surgical and endovascular interventions implemented in the care of these complex patients.

  8. Emergency endovascular coiling of a ruptured giant splenic artery aneurysm

    Directory of Open Access Journals (Sweden)

    Erika Wernheden, MD

    2017-12-01

    Full Text Available Splenic artery aneurysms (SAAs are the third most common abdominal aneurysm. Endovascular treatment of SAAs is preferred, and coiling is the most commonly used technique. Ruptured giant (>5 cm SAAs are usually treated with open surgery including splenectomy. We present a rare case of a ruptured 15-cm giant SAA in an 84-year-old woman treated successfully with emergency endovascular coiling. To our knowledge, this is one of the few reports of emergency endovascular treatment for ruptured giant SAA.

  9. Computed tomography-based anatomic characterization of proximal aortic dissection with consideration for endovascular candidacy.

    Science.gov (United States)

    Moon, Michael C; Greenberg, Roy K; Morales, Jose P; Martin, Zenia; Lu, Qingsheng; Dowdall, Joseph F; Hernandez, Adrian V

    2011-04-01

    Proximal aortic dissections are life-threatening conditions that require immediate surgical intervention to avert an untreated mortality rate that approaches 50% at 48 hours. Advances in computed tomography (CT) imaging techniques have permitted increased characterization of aortic dissection that are necessary to assess the design and applicability of new treatment paradigms. All patients presenting during a 2-year period with acute proximal aortic dissections who underwent CT scanning were reviewed in an effort to establish a detailed assessment of their aortic anatomy. Imaging studies were assessed in an effort to document the location of the primary proximal fenestration, the proximal and distal extent of the dissection, and numerous morphologic measurements pertaining to the aortic valve, root, and ascending aorta to determine the potential for an endovascular exclusion of the ascending aorta. During the study period, 162 patients presented with proximal aortic dissections. Digital high-resolution preoperative CT imaging was performed on 76 patients, and 59 scans (77%) were of adequate quality to allow assessment of anatomic suitability for treatment with an endograft. In all cases, the dissection plane was detectable, yet the primary intimal fenestration was identified in only 41% of the studies. Scans showed 24 patients (32%) appeared to be anatomically amenable to such a repair (absence of valvular involvement, appropriate length and diameter of proximal sealing regions, lack of need to occlude coronary vasculature). Of the 42 scans that were determined not to be favorable for endovascular repair, the most common exclusion finding was the absence of a proximal landing zone (n = 15; 36%). Appropriately protocoled CT imaging provides detailed anatomic information about the aortic root and ascending aorta, allowing the assessment of which dissections have proximal fenestrations that may be amenable to an endovascular repair. Copyright © 2011 Society for

  10. Endovascular Revascularization of Symptomatic Infrapopliteal Arteriosclerotic Occlusive Disease: Comparison of Atherectomy and Angioplasty

    Science.gov (United States)

    Tan, Tze-Woei; Semaan, Elie; Nasr, Wael; Eberhardt, Robert T.; Hamburg, Naomi; Doros, Gheorghe; Rybin, Denis; Shaw, Palma M.; Farber, Alik

    2011-01-01

    The preferred method for revascularization of symptomatic infrapopliteal arterial occlusive disease (IPAD) has traditionally been open vascular bypass. Endovascular techniques have been increasingly applied to treat tibial disease with mixed results. We evaluated the short-term outcome of percutaneous infrapopliteal intervention and compared the different techniques used. A retrospective analysis of consecutive patients undergoing endovascular treatment for infrapopliteal arterial occlusive lesions between 2003 and 2007 in a tertiary teaching hospital was performed. Patient demographic data, indication for intervention, and periprocedural complications were recorded. Periprocedural and short-term outcomes were measured and compared. Forty-nine infrapopliteal arteries in 35 patients were treated. Twenty vessels (15 patients) underwent angioplasty and 29 vessels (20 patients) were treated with atherectomy. Demographic and angiographic characteristics were similar between the groups. Twenty-six patients had concurrent femoral and/or popliteal artery interventions. Overall, technical success was 90% and similar between angioplasty and atherectomy groups (85% versus 93%, p = NS). The vessel-specific complication rate was 10% and was similar between both groups (angioplasty 5% versus atherectomy 14%, p = NS). One dissection occurred in the angioplasty group; one perforation and three thromboembolic events occurred in the atherectomy group. Limb salvage and freedom from reintervention at 6 months were 81% and 68%, respectively, and were not significantly different between the angioplasty and atherectomy groups. Endovascular intervention for IPAD had acceptable periprocedural and short-term success rates in our high-risk patient population. Both atherectomy and angioplasty can be used successfully to treat symptomatic IPAD. PMID:22532766

  11. Endovascular recanalization of native chronic total occlusions in patients with failed lower-extremity bypass grafts.

    Science.gov (United States)

    Wrigley, Clinton W; Vance, Ansar; Niesen, Timothy; Grilli, Christopher; Velez, J Daniel; Agriantonis, Demetrios J; Kimbiris, George; Garcia, Mark J; Leung, Daniel A

    2014-09-01

    To investigate the feasibility, safety, and outcome of endovascular recanalization of native chronic total occlusions (CTOs) in patients with failed lower-extremity bypass grafts. Retrospective review of 19 limbs in 18 patients with failed lower-extremity bypass grafts that underwent recanalization of native arterial occlusions between February 2009 and April 2013 was performed. Nine of the limbs presented with acute ischemia and 10 presented with chronic ischemia, including eight with critical limb ischemia and two with disabling claudication. The mean patency of the failed bypass grafts (63% venous) was 27 months. All limbs had Transatlantic Inter-Society Consensus class D lesions involving the native circulation. Technical success of the endovascular recanalization procedure was achieved in all but one limb (95%). The mean ankle brachial indices before and after treatment were 0.34 and 0.73, respectively. There were no major complications or emergency amputations. Mean patient follow-up was 64 weeks, and two patients were lost to follow-up. Primary patency rates at 3, 6, and 12 months were 87%, 48%, and 16%, respectively. Successful secondary procedures were performed in seven patients, with secondary patency rates at 3, 6, and 12 months of 88%, 73%, and 44%, respectively. Limb salvage rates at 12 and 24 months were 94% and 65%, and amputation-free survival rates at 12 and 24 months were 87% and 60%, respectively. Endovascular recanalization of native CTOs in patients with failed lower-extremity bypass grafts is technically feasible and safe and results in acceptable limb salvage. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  12. CT perfusion-guided patient selection for endovascular recanalization in acute ischemic stroke: a multicenter study.

    Science.gov (United States)

    Turk, Aquilla S; Magarick, Jordan Asher; Frei, Don; Fargen, Kyle Michael; Chaudry, Imran; Holmstedt, Christine A; Nicholas, Joyce; Mocco, J; Turner, Raymond D; Huddle, Daniel; Loy, David; Bellon, Richard; Dooley, Gwendolyn; Adams, Robert; Whaley, Michelle; Fanale, Chris; Jauch, Edward

    2013-11-01

    The treatment of acute ischemic stroke is traditionally centered on time criteria, although recent evidence suggests that physiologic neuroimaging may be useful. In a multicenter study we evaluated the use of CT perfusion, regardless of time from symptom onset, in patients selected for intra-arterial treatment of ischemic stroke. Three medical centers retrospectively assessed stroke patients with a National Institute of Health Stroke Scale of ≥ 8, regardless of time from symptom onset. CT perfusion maps were qualitatively assessed. Patients with defined salvageable penumbra underwent intra-arterial revascularization of their occlusion. Functional outcome using the modified Rankin Score (mRS) was recorded. Two hundred and forty-seven patients were selected to undergo intra-arterial treatment based on CT perfusion imaging. The median time from symptom onset to procedure was 6 h. Patients were divided into two groups for analysis: ≤ 8 h and >8 h from symptom onset to endovascular procedure. We found no difference in functional outcome between the two groups (42.8% and 41.9% achieved 90-day mRS ≤ 2, respectively (p=1.0), and 54.9% vs 55.4% (p=1.0) achieved 90-day mRS ≤ 3, respectively). Overall, 48 patients (19.4%) had hemorrhages, of which 20 (8.0%) were symptomatic, with no difference between the groups (p=1.0). In a multicenter study, we demonstrated similar rates of good functional outcome and intracranial hemorrhage in patients with ischemic stroke when endovascular treatment was performed based on CT perfusion selection rather than time-guided selection. Our findings suggest that physiologic imaging-guided patient selection rather than time for endovascular reperfusion in ischemic stroke may be effective and safe.

  13. Aortic Branch Artery Pseudoaneurysms Associated with Intramural Hematoma: When and How to Do Endovascular Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Carlo; Rossi, Umberto G., E-mail: urossi76@hotmail.com; Seitun, Sara [IRCCS San Martino University Hospital, IST, National Institute for Cancer Research, Department of Radiology and Interventional Radiology (Italy); Scarano, Flavio; Passerone, Giancarlo [IRCCS San Martino University Hospital, IST, National Institute for Cancer Research, Department of Cardiac Surgery (Italy); Williams, David M. [University of Michigan Medical Center, Department of Radiology, Division of Vascular and Interventional Radiology (United States)

    2013-04-15

    To describe when and how to perform endovascular embolization of aortic branch artery pseudoaneurysms associated with type A and type B intramural hematoma (IMH) involving the descending thoracic and abdominal aorta (DeBakey I and III) that increased significantly in size during follow-up. Sixty-one patients (39 men; mean {+-} standard deviation age 66.1 {+-} 11.2 years) with acute IMH undergoing at least two multidetector computed tomographic examinations during follow-up for 12 months or longer were enrolled. Overall, 48 patients (31 men, age 65.9 {+-} 11.5) had type A and type B IMH involving the descending thoracic and abdominal aorta (DeBakey I and III). Among the 48 patients, 26 (54 %; 17 men, aged 64.3 {+-} 11.4 years) had 71 aortic branch artery pseudoaneurysms. Overall, during a mean follow-up of 22.1 {+-} 9.5 months (range 12-42 months), 31 (44 %) pseudoaneurysms disappeared; 22 (31 %) decreased in size; two (3 %) remained stable; and 16 (22 %) increased in size. Among the 16 pseudoaneurysms with increasing size, five of these (three intercostal arteries, one combined intercostobronchial/intercostal arteries, one renal artery), present in five symptomatic patients, had a significant increase in size (thickness >10 mm; width and length >20 mm). These five patients underwent endovascular embolization with coils and/or Amplatzer Vascular Plug. In all patients, complete thrombosis and exclusion of aortic pseudoaneurysm and relief of back pain were achieved. Aortic branch artery pseudoaneurysms associated with type A and type B IMH involving the descending thoracic and abdominal aorta (DeBakey I and III) may be considered relatively benign lesions. However, a small number may grow in size or extend longitudinally with clinical symptoms during follow-up, and in these cases, endovascular embolization can be an effective and safe procedure.

  14. Lesion complexity drives the cost of superficial femoral artery endovascular interventions

    Science.gov (United States)

    Walker, Karen L.; Nolan, Brian W.; Columbo, Jesse A.; Rzucidlo, Eva M.; Goodney, Philip P.; Walsh, Daniel B.; Atkinson, Benjamin J.; Powell, Richard J.

    2017-01-01

    Objective Patients who undergo endovascular treatment of superficial femoral artery (SFA) disease vary greatly in lesion complexity and treatment options. This study examined the association of lesion severity and cost of SFA stenting and to determine if procedure cost affects primary patency at 1 year. Methods A retrospective record review identified patients undergoing initial SFA stenting between January 1, 2010, and February 1, 2012. Medical records were reviewed to collect data on demographics, comorbidities, indication for the procedure, TransAtlantic Inter-Society Consensus (TASC) II severity, and primary patency. The interventional radiology database and hospital accounting database were queried to determine cost drivers of SFA stenting. Procedure supply cost included any item with a bar code used for the procedure. Associations between cost drivers and lesion characteristics were explored. Primary patency was determined using Kaplan-Meier survival curves and a log-rank test. Results During the study period, 95 patients underwent stenting in 98 extremities; of these, 61% of SFA stents were performed for claudication, with 80% of lesions classified as TASC II A or B. Primary patency at 1 year was 79% for the entire cohort. The mean total cost per case was $10,333. Increased procedure supply cost was associated with adjunct device use, the number of stents, and TASC II severity. Despite higher costs of treating more complex lesions, primary patency at 1 year was similar at 80% for high-cost (supply cost >$4000) vs 78% for low-cost (supply cost <$4000) interventions. Conclusions SFA lesion complexity, as defined by TASC II severity, drives the cost of endovascular interventions but does not appear to disadvantage patency at 1 year. Reimbursement agencies should consider incorporating disease severity into reimbursement algorithms for lower extremity endovascular interventions. PMID:26206581

  15. Endovascular recanalization of acute intracranial vertebrobasilar artery occlusion using local fibrinolysis and additional balloon angioplasty

    International Nuclear Information System (INIS)

    Kashiwagi, Junji; Okahara, Mika; Kiyosue, Hiro; Tanoue, Shuichi; Sagara, Yoshiko; Mori, Hiromu; Hori, Yuzo; Abe, Toshi

    2010-01-01

    Vertebrobasilar artery occlusion (VBO) produces high mortality and morbidity due to low recanalization rate utilization in endovascular therapy. The use of percutaneous transluminal angioplasty (PTA) to improve recanalization rate additional to local intra-arterial fibrinolysis (LIF) was investigated in this study. Results obtained following recanalization therapy in acute intracranial VBO are reported. Eighteen consecutive patients with acute VBO underwent LIF with or without PTA, from August 2000 to May 2006. Eight patients were treated using LIF alone, and ten required additional PTA. Rate of recanalization, neurological status before treatment, and clinical outcomes were evaluated. Of 18 patients, 17 achieved recanalization. One procedure-related complication of subarachnoid hemorrhage occurred. Overall survival rate was 94.4% at discharge. Seven patients achieved good outcomes [modified Rankin scale (mRS) 0-2], and the other 11 had poor outcomes (mRS 3-6). Five of six patients who scored 9-14 on the Glasgow Coma Scale (GCS) before treatment displayed good outcomes, whereas ten of 12 patients who scored 3-8 on the GCS showed poor outcomes. GCS prior to treatment showed a statistically significant correlation to outcomes (p < 0.05). Moreover, the National Institutes of Health Stroke Scale (NIHSS) before treatment correlated well with mRS (correlation coefficient 0.487). No statistical difference between the good and poor outcome groups was observed for the duration of symptoms, age, etiology, and occlusion site. Endovascular recanalization can reduce mortality and morbidity of acute VBO. Good GCS and NIHSS scores prior to treatment can predict the efficacy of endovascular recanalization. (orig.)

  16. Endovascular treatment of acute arterial complications after living-donor liver transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, G.S. [Department of Diagnostic Radiology, Ajou University Hospital, School of Medicine, San 5, Wonchun-dong, Youngtong-gu, Suwon, Gyeonggido 443-721 (Korea, Republic of); Won, J.H. [Department of Diagnostic Radiology, Ajou University Hospital, School of Medicine, San 5, Wonchun-dong, Youngtong-gu, Suwon, Gyeonggido 443-721 (Korea, Republic of)], E-mail: wonkwak@ajou.ac.kr; Wang, H.J.; Kim, B.W. [Department of Surgery, Ajou University Hospital, School of Medicine, San 5, Wonchun-dong, Youngtong-gu, Suwon, Gyeonggido 443-721 (Korea, Republic of); Lee, B.M. [Department of Surgery, Aerospace medical center, Ssangsu-ri, Cheongwon-gun, Chungcheongbuk-do 363-849 (Korea, Republic of)

    2008-10-15

    Aim: The aim of this study was to evaluate the efficacy of endovascular treatment for acute arterial complications following living-donor liver transplantation (LDLT). Materials and methods: Of 79 LDLT patients, 17 (mean age 48 {+-} 8 years, range 33-66 years) who had acute arterial complications and underwent endovascular treatment were evaluated. Transcatheter arterial embolization was performed to control peritoneal bleeding. Catheter-directed thrombolysis using urokinase was performed in hepatic artery thromboses. The locations of complications and materials used were evaluated. The technical and clinical success rates were calculated. Results: Twenty-three acute arterial complications, including four hepatic artery thromboses and 19 cases of peritoneal haemorrhages were identified in 22 angiographic sessions in 17 patients. The mean duration between LDLT and first angiography was 3.2 {+-} 3.5 days (range 1-13 days). Hepatic artery recanalization with catheter-directed thrombolysis using urokinase was achieved in two patients. Transcatheter arterial embolization for peritoneal bleeding was successfully performed in 16 cases. The most common bleeding focus was the right inferior phrenic artery. Additional surgical management was needed in five patients to control bleeding or hepatic artery recanalization. Technical and clinical success rates of transcatheter arterial embolization were 84.2 and 63.1%, respectively. Overall technical success was achieved in 18 of 23 arterial complications (78.2%), and clinical success was achieved in 14 of 23 arterial complications (60.8%). Conclusion: Endovascular treatment for the acute arterial complications of haemorrhage or thrombosis in LDLT patients is safe and effective. Therefore, it should be considered as the first line of treatment in selective cases.

  17. Standards for Endovascular Neurosurgical Training and Certification of the Society of Korean Endovascular Neurosurgeons 2013

    Science.gov (United States)

    Shin, Dong-Seong; Park, Sukh-Que; Kang, Hyun-Seung; Yoon, Seok-Mann; Cho, Jae-Hoon; Lim, Dong-Jun; Baik, Min-Woo; Kwon, O Ki

    2014-01-01

    The need for standard endovascular neurosurgical (ENS) training programs and certification in Korea cannot be overlooked due to the increasing number of ENS specialists and the expanding ENS field. The Society of Korean Endovascular Neurosurgeons (SKEN) Certification Committee has prepared training programs and certification since 2010, and the first certificates were issued in 2013. A task force team (TFT) was organized in August 2010 to develop training programs and certification. TFT members researched programs and systems in other countries to develop a program that best suited Korea. After 2 years, a rough draft of the ENS training and certification regulations were prepared, and the standard training program title was decided. The SKEN Certification Committee made an official announcement about the certification program in March 2013. The final certification regulations comprised three major parts: certified endovascular neurosurgeons (EN), certified ENS institutions, and certified ENS training institutions. Applications have been evaluated and the results were announced in June 2013 as follows: 126 members received EN certification and 55 hospitals became ENS-certified institutions. The SKEN has established standard ENS training programs together with a certification system, and it is expected that they will advance the field of ENS to enhance public health and safety in Korea. PMID:24851145

  18. Endovascular treatment of a true posterior communicating artery aneurysm.

    Science.gov (United States)

    Munarriz, Pablo M; Castaño-Leon, Ana M; Cepeda, Santiago; Campollo, Jorge; Alén, Jose F; Lagares, Alfonso

    2014-01-01

    Posterior communicating artery (PCoA) aneurysms are most commonly located at the junction of the internal carotid artery and the PCoA. "True" PCoA aneurysms, which originate from the PCoA itself, are rarely encountered. Most previously reported cases were treated surgically mainly before the endovascular option became available. A 53-year-old male presented with sudden onset of right hemiparesis and aphasia. Left middle cerebral artery stroke was diagnosed. Further studies revealed a 3 mm left PCoA aneurysm arising from the PCoA itself, attached to neither the internal carotid artery nor the posterior cerebral artery. Endovascular treatment was performed and the aneurysm was coiled completely. Technical advances in endovascular interventional technology have permitted an additional approach to these lesions. The possible endovascular significance of the treatment of true PCoA aneurysms is discussed.

  19. Update on acute endovascular and surgical stroke treatment

    DEFF Research Database (Denmark)

    Kondziella, D; Cortsen, M; Eskesen, V

    2013-01-01

    Emergency stroke care has become a natural part of the emerging discipline of neurocritical care and demands close cooperation between the neurologist and neurointerventionists, neurosurgeons, and anesthesiologists. Endovascular treatment (EVT), including intra-arterial thrombolysis, mechanical...

  20. Endovascular Management of Vascular Injury during Transsphenoidal Surgery

    OpenAIRE

    Çinar, C.; Bozkaya, H.; Parildar, M.; Oran, I.

    2013-01-01

    Vascular injury is an unusual and serious complication of transsphenoidal surgery. We aimed to define the role of angiography and endovascular treatment in patients with vascular injuries occurring during transsphenoidal surgery.

  1. The importance of expert feedback during endovascular simulator training.

    LENUS (Irish Health Repository)

    Boyle, Emily

    2011-07-01

    Complex endovascular skills are difficult to obtain in the clinical environment. Virtual reality (VR) simulator training is a valuable addition to current training curricula, but is there a benefit in the absence of expert trainers?

  2. Hepatic vascular injury: Clinical profile, endovascular management and outcomes

    Directory of Open Access Journals (Sweden)

    Bishav Mohan

    2013-01-01

    Conclusion: Prompt endovascular management is the modality of choice in comparison to NOM without AE in both pediatric and adult patients with hemodynamically compromised inaccessible intra hepatic vascular trauma.

  3. Modern radiosurgical and endovascular classification schemes for brain arteriovenous malformations.

    Science.gov (United States)

    Tayebi Meybodi, Ali; Lawton, Michael T

    2018-05-04

    Stereotactic radiosurgery (SRS) and endovascular techniques are commonly used for treating brain arteriovenous malformations (bAVMs). They are usually used as ancillary techniques to microsurgery but may also be used as solitary treatment options. Careful patient selection requires a clear estimate of the treatment efficacy and complication rates for the individual patient. As such, classification schemes are an essential part of patient selection paradigm for each treatment modality. While the Spetzler-Martin grading system and its subsequent modifications are commonly used for microsurgical outcome prediction for bAVMs, the same system(s) may not be easily applicable to SRS and endovascular therapy. Several radiosurgical- and endovascular-based grading scales have been proposed for bAVMs. However, a comprehensive review of these systems including a discussion on their relative advantages and disadvantages is missing. This paper is dedicated to modern classification schemes designed for SRS and endovascular techniques.

  4. Construct canine intracranial aneurysm model by endovascular technique

    International Nuclear Information System (INIS)

    Liang Xiaodong; Liu Yizhi; Ni Caifang; Ding Yi

    2004-01-01

    Objective: To construct canine bifurcation aneurysms suitable for evaluating the exploration of endovascular devices for interventional therapy by endovascular technique. Methods: The right common carotid artery of six dogs was expanded with a pliable balloon by means of endovascular technique, then embolization with detached balloon was taken at their originations DAS examination were performed on 1, 2, 3 d after the procedurse. Results: 6 aneurysm models were created in six dogs successfully with the mean width and height of the aneurysms decreasing in 3 days. Conclusions: This canine aneurysm model presents the virtue in the size and shape of human cerebral bifurcation saccular aneurysms on DSA image, suitable for developing the exploration of endovascular devices for aneurismal therapy. The procedure is quick, reliable and reproducible. (authors)

  5. Patterns in neurosurgical adverse events: endovascular neurosurgery.

    Science.gov (United States)

    Wong, Judith M; Ziewacz, John E; Panchmatia, Jaykar R; Bader, Angela M; Pandey, Aditya S; Thompson, B Gregory; Frerichs, Kai; Gawande, Atul A

    2012-11-01

    As part of a project to devise evidence-based safety interventions for specialty surgery, the authors sought to review current evidence in endovascular neurosurgery concerning the frequency of adverse events in practice, their patterns, and current methods of reducing the occurrence of these events. This review represents part of a series of papers written to consolidate information about these events and preventive measures as part of an ongoing effort to ascertain the utility of devising system-wide policies and safety tools to improve neurosurgical practice. Based on a review of the literature, thromboembolic events appeared to be the most common adverse events in endovascular neurosurgery, with a reported incidence ranging from 2% to 61% depending on aneurysm rupture status and mode of detection of the event. Intraprocedural and periprocedural prevention and rescue regimens are advocated to minimize this risk; however, evidence on the optimal use of anticoagulant and antithrombotic agents is limited. Furthermore, it is unknown what proportion of eligible patients receive any prophylactic treatment. Groin-site hematoma is the most common access-related complication. Data from the cardiac literature indicate an overall incidence of 9% to 32%, but data specific to neuroendovascular therapy are scant. Manual compression, compression adjuncts, and closure devices are used with varying rates of success, but no standardized protocols have been tested on a broad scale. Contrast-induced nephropathy is one of the more common causes of hospital-acquired renal insufficiency, with an incidence of 30% in high-risk patients after contrast administration. Evidence from medical fields supports the use of various preventive strategies. Intraprocedural vessel rupture is infrequent, with the reported incidence ranging from 1% to 9%, but it is potentially devastating. Improvements in device technology combined with proper endovascular technique play an important role in reducing

  6. Endovascular treatment of splenic artery aneurysms

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Fontana, Federico; Dizonno, Massimiliano; Fugazzola, Carlo; Castelli, Patrizio

    2005-01-01

    Purpose. To assess the feasibility and effectiveness of endovascular treatment of splenic artery aneurysm (SAAs). Materials and methods. Between May 2000 and June 2003 we treated 11 true SAAs in 9 patients (7 females and 2 males; mean age 58 years), 8 saccular and 3 fusiform, 4 located at the middle tract of the splenic artery, 5 at the distal tract and 2 intra-parenchymal. The diagnosis was performed with colour-Doppler ultrasound and/or CT-angiography; 7 patients were symptomless, 1 had left hypochondriac pain, and 1 had acute abdomen caused by a ruptured SAA. Four SAAs were treated by micro coil embolisation of the aneurysmal sac with preservation of splenic artery patency; in 2 cases this was associated with transcatheter injection of N-butyl-2-cyanoacrylate. Four cases were treated by endovascular ligature, with sectoral spleen ischaemia. One ruptured SAA received emergency treatment with splenic artery cyanoacrylate embolisation. Two intra-parenchymal SAAs were excluded, one by cyanoacrylate embolisation of the afferent artery and the other by transcatheter thrombin injection in the aneurysmal sac. Results. Technical success was observed in all cases (in 10/11 at the end of the procedure; in 1/11 at CT performed 3 days after the procedure). The follow-up (mean 18 months; range 6-36) was performed by colour-Doppler ultrasound and/or CT-angiography 3, 6 and 12 months after the procedure and subsequently once a year; the complete exclusion of the aneurysms was confirmed in 11/11 cases. The complications were: 4 cases of mild pleuritis; fever and left hypochondriac pain 1 day after the procedure (in the same 4 patients and in one other case); 5 cases of sectorial spleen ischaemia and 1 case of diffuse spleen infarction with partial revascularization by collateral vessels. No alteration of the levels of pancreatic enzymes was found; a transitory increase in platelet count occurred only in the patient with diffuse spleen infarction. Conclusions. Using different

  7. Embolization by micro navigation for treatment of persistent type 2 Endoleaks after endovascular abdominal aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    Bruno Lorenção de Almeida

    2014-12-01

    Full Text Available Background:Endovascular repair has become established as a safe and effective method for treatment of abdominal aortic aneurysms. One major complication of this treatment is leakage, or endoleaks, of which type 2 leaks are the most common.Objective:To conduct a brief review of the literature and evaluate the safety and effectiveness of embolization by micronavigation for treatment of type 2 endoleaks.Method:A review of medical records from patients who underwent endovascular repair of abdominal aortic aneurysms identified 5 patients with persistent type 2 endoleaks. These patients were submitted to embolization by micronavigation.Results:In all cases, angiographic success was achieved and control CT scans showed absence of type 2 leaks and aneurysm sacs that had reduced in size after the procedure.Conclusion:Treatment of type 2 endoleaks using embolization by micronavigation is an effective and safe method and should be considered as a treatment option for this complication after endovascular repair of abdominal aortic aneurysms.

  8. Extra-Thoracic Supra-aortic Bypass Surgery Is Safe in Thoracic Endovascular Aortic Repair and Arterial Occlusive Disease Treatment.

    Science.gov (United States)

    Gombert, Alexander; van Issum, Lea; Barbati, Mohammad E; Grommes, Jochen; Keszei, Andras; Kotelis, Drosos; Jalaie, Houman; Greiner, Andreas; Jacobs, Michael J; Kalder, Johannes

    2018-04-20

    The safety and feasibility of supra-aortic debranching as part of endovascular aortic surgery or as a treatment option for arterial occlusive disease (AOD) remains controversial. The aim of this study was to assess the clinical outcome of this surgery. This single centre, retrospective study included 107 patients (mean age 69.2 years, 38.4% women) who underwent supra-aortic bypass surgery (carotid-subclavian bypass, carotid-carotid bypass, and carotid-carotid-subclavian bypass) because of thoracic or thoraco-abdominal endovascular aortic repair (57%; 61/107) or as AOD treatment (42.9%; 46/107) between January 2006 and January 2015. Mortality, morbidity with a focus on neurological complications, and patency rate were assessed. Twenty-six of 107 (14.2%) of the debranching patients were treated under emergency conditions because of acute type B dissection or symptomatic aneurysm. Follow up, conducted by imaging interpretation and telephone interviews, continued till March 2017 (mean 42.1, 0-125, months). The in hospital mortality rate was 10.2% (11/107), all of these cases from the debranching group and related to emergency procedures (p supra-aortic bypass surgery involves low complication rates and high mid-term bypass patency rates. It is a safe and feasible treatment option in the form of debranching in combination with endovascular aortic aneurysm repair and in AOD. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  9. Complications in Endovascular Neurosurgery: Critical Analysis and Classification.

    Science.gov (United States)

    Ravindra, Vijay M; Mazur, Marcus D; Park, Min S; Kilburg, Craig; Moran, Christopher J; Hardman, Rulon L; Couldwell, William T; Taussky, Philipp

    2016-11-01

    Precisely defining complications, which are used to measure overall quality, is necessary for critical review of delivery of care and quality improvement in endovascular neurosurgery, which lacks common definitions for complications. Furthermore, in endovascular interventions, events that may be labeled complications may not always negatively affect outcome. Our objective is to provide precise definitions for quality evaluation within endovascular neurosurgery. Thus, we propose an endovascular-specific classification system of complications based on our own patient series. This single-center review included all patients who had endovascular interventions from September 2013 to August 2015. Complication types were analyzed, and a descriptive analysis was undertaken to calculate the incidence of complications overall and in each category. Two hundred and seventy-five endovascular interventions were performed in 245 patients (65% female; mean age, 55 years). Forty complications occurred in 39 patients (15%), most commonly during treatment of intracranial aneurysms (24/40). Mechanical complications (eg, device deployment, catheter, or closure device failure) occurred in 8/40, technical complications (eg, failure to deploy flow diverter, unintended embolization, air emboli, retroperitoneal hemorrhage, dissection) in 11/40, judgment errors (eg, patient or equipment selection) in 9/40, and critical events (eg, groin hematoma, hemorrhagic or thromboembolic complications) in 12/40 patients. Only 12/40 complications (30%) resulted in new neurologic deficits, vessel injury requiring surgery, or blood transfusion. We propose an endovascular-specific classification system of complications with 4 categories: mechanical, technical, judgment errors, and critical events. This system provides a framework for future studies and quality control in endovascular neurosurgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. The Effect of Endovascular Revascularization of Common Iliac Artery Occlusions on Erectile Function

    International Nuclear Information System (INIS)

    Gur, Serkan; Ozkan, Uğur; Onder, Hakan; Tekbas, Güven; Oguzkurt, Levent

    2013-01-01

    To determine the incidence of erectile dysfunction in patients with common iliac artery (CIA) occlusive disease and the effect of revascularization on erectile function using the sexual health inventory for males (SHIM) questionnaire. All patients (35 men; mean age 57 ± 5 years; range 42–67 years) were asked to recall their sexual function before and 1 month after iliac recanalization. Univariate and multivariate analyses were performed to determine variables effecting improvement of impotence. The incidence of impotence in patients with CIA occlusion was 74% (26 of 35) preoperatively. Overall 16 (46%) of 35 patients reported improved erectile function after iliac recanalization. The rate of improvement of impotence was 61.5% (16 of 26 impotent patients). Sixteen patients (46%), including seven with normal erectile function before the procedure, had no change. Three patients (8%) reported deterioration of their sexual function, two of whom (6%) had normal erectile function before the procedure. The median SHIM score increased from 14 (range 4–25) before the procedure to 20 (range 1–25) after the procedure (P = 0.005). The type of recanalization, the age of the patients, and the length of occlusion were related to erectile function improvement in univariate analysis. However, these factors were not independent factors for improvement of erectile dysfunction in multivariate analysis (P > 0.05). Endovascular recanalization of CIA occlusions clearly improves sexual function. More than half of the patients with erectile dysfunction who underwent endovascular recanalization of the CIA experienced improvement.

  11. Endovascular Treatment of Late Thoracic Aortic Aneurysms after Surgical Repair of Congenital Aortic Coarctation in Childhood

    Science.gov (United States)

    Juszkat, Robert; Perek, Bartlomiej; Zabicki, Bartosz; Trojnarska, Olga; Jemielity, Marek; Staniszewski, Ryszard; Smoczyk, Wiesław; Pukacki, Fryderyk

    2013-01-01

    Background In some patients, local surgery-related complications are diagnosed many years after surgery for aortic coarctation. The purposes of this study were: (1) to systematically evaluate asymptomatic adults after Dacron patch repair in childhood, (2) to estimate the formation rate of secondary thoracic aortic aneurysms (TAAs) and (3) to assess outcomes after intravascular treatment for TAAs. Methods This study involved 37 asymptomatic patients (26 female and 11 male) who underwent surgical repair of aortic coarctation in the childhood. After they had reached adolescence, patients with secondary TAAs were referred to endovascular repair. Results Follow-up studies revealed TAA in seven cases (19%) (including six with the gothic type of the aortic arch) and mild recoarctation in other six (16%). Six of the TAA patients were treated with stentgrafts, but one refused to undergo an endovascular procedure. In three cases, stengrafts covered the left subclavian artery (LSA), in another the graft was implanted distally to the LSA. In two individuals, elective hybrid procedures were performed with surgical bypass to the supraaortic arteries followed by stengraft implantation. All subjects survived the secondary procedures. One patient developed type Ia endoleak after stentgraft implantation that was eventually treated with a debranching procedure. Conclusions The long-term course of clinically asymptomatic patients after coarctation patch repair is not uncommonly complicated by formation of TAAs (particularly in individuals with the gothic pattern of the aortic arch) that can be treated effectively with stentgrafts. However, in some patients hybrid procedures may be necessary. PMID:24386233

  12. The Effect of Endovascular Revascularization of Common Iliac Artery Occlusions on Erectile Function

    Energy Technology Data Exchange (ETDEWEB)

    Gur, Serkan, E-mail: mserkangur@yahoo.com [Sifa Hospital, Department of Radiology (Turkey); Ozkan, Ugur [Baskent University, Department of Radiology, Faculty of Medicine (Turkey); Onder, Hakan; Tekbas, Gueven [Dicle University, Department of Radiology, Faculty of Medicine (Turkey); Oguzkurt, Levent [Baskent University, Department of Radiology, Faculty of Medicine (Turkey)

    2013-02-15

    To determine the incidence of erectile dysfunction in patients with common iliac artery (CIA) occlusive disease and the effect of revascularization on erectile function using the sexual health inventory for males (SHIM) questionnaire. All patients (35 men; mean age 57 {+-} 5 years; range 42-67 years) were asked to recall their sexual function before and 1 month after iliac recanalization. Univariate and multivariate analyses were performed to determine variables effecting improvement of impotence. The incidence of impotence in patients with CIA occlusion was 74% (26 of 35) preoperatively. Overall 16 (46%) of 35 patients reported improved erectile function after iliac recanalization. The rate of improvement of impotence was 61.5% (16 of 26 impotent patients). Sixteen patients (46%), including seven with normal erectile function before the procedure, had no change. Three patients (8%) reported deterioration of their sexual function, two of whom (6%) had normal erectile function before the procedure. The median SHIM score increased from 14 (range 4-25) before the procedure to 20 (range 1-25) after the procedure (P = 0.005). The type of recanalization, the age of the patients, and the length of occlusion were related to erectile function improvement in univariate analysis. However, these factors were not independent factors for improvement of erectile dysfunction in multivariate analysis (P > 0.05). Endovascular recanalization of CIA occlusions clearly improves sexual function. More than half of the patients with erectile dysfunction who underwent endovascular recanalization of the CIA experienced improvement.

  13. Retinal Endovascular Surgery with Tissue Plasminogen Activator Injection for Central Retinal Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Yuta Takata

    2018-06-01

    Full Text Available Purpose: To report 2 cases of central retinal artery occlusion (CRAO who underwent retinal endovascular surgery with injection of tissue plasminogen activator (tPA into the retinal artery and showed a remarkable improvement in visual acuity and retinal circulation. Methods: Standard 25-G vitrectomy was performed under local anesthesia. Simultaneously, tPA (80,000 units/mL solution was injected into the retinal artery of the optic disc for 2–3 min using a microneedle. Changes in visual acuity, fundus photography, optical coherence tomography (OCT, fluorescein angiography, and laser speckle flowgraphy (LSFG results were examined. Results: Both cases could be treated within 12 h after the onset of CRAO. Case 1 was a 47-year-old woman. Her visual acuity improved from counting fingers before operation to 0.08 logMAR 1 month after the surgery. However, thinning of the retina at the macula was observed by OCT. Case 2 was a 70-year-old man. His visual acuity improved from counting fingers to 0.1 logMAR 2 months after the surgery. Both fluorescein angiography and LSFG showed improvement in retinal circulation after the surgery in case 2. Conclusions: Retinal endovascular surgery with injection of tPA into the retinal artery was feasible and may be a way to improve visual acuity and retinal circulation when performed in the acute phase of CRAO.

  14. Endovascular image-guided interventions (EIGIs)

    International Nuclear Information System (INIS)

    Rudin, Stephen; Bednarek, Daniel R.; Hoffmann, Kenneth R.

    2008-01-01

    Minimally invasive interventions are rapidly replacing invasive surgical procedures for the most prevalent human disease conditions. X-ray image-guided interventions carried out using the insertion and navigation of catheters through the vasculature are increasing in number and sophistication. In this article, we offer our vision for the future of this dynamic field of endovascular image-guided interventions in the form of predictions about (1) improvements in high-resolution detectors for more accurate guidance, (2) the implementation of high-resolution region of interest computed tomography for evaluation and planning, (3) the implementation of dose tracking systems to control patient radiation risk, (4) the development of increasingly sophisticated interventional devices, (5) the use of quantitative treatment planning with patient-specific computer fluid dynamic simulations, and (6) the new expanding role of the medical physicist. We discuss how we envision our predictions will come to fruition and result in the universal goal of improved patient care.

  15. Endovascular Treatment of an Aortoiliac Tuberculous Pseudoaneurysm

    International Nuclear Information System (INIS)

    Villegas, Miguel O.; Mereles, Alberto Pérez; Tamashiro, Gustavo A.; Dini, Andrés E.; Mollón, Ana P.; De Cándido, Laura V.; Zelaya, Denis A.; Soledispa-Suarez, Carlos I.; Denato, Sergio; Tamashiro, Alberto; Diaz, Jose A.

    2013-01-01

    We report a rare case of a tuberculous mycotic aortoiliac pseudoaneurysm treated with an endovascular procedure and follow-up of 36 months. The patient was a white 72-year-old man with pulmonary tuberculosis and a former smoker with hypertension, chronic renal failure, and dyslipidemia. A computed tomographic scan of the abdomen and pelvis revealed a left paravertebral cavity with fluid content and involvement of vertebrae L2–L4. After a surgical repair attempt, the patient was treated with the implant of a bifurcated endoprosthesis. Because it is unlikely that any center has extensive experience in the management of this rare manifestation of the disease, we reviewed the literature for similar cases.

  16. Endovascular Treatment of an Aortoiliac Tuberculous Pseudoaneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Villegas, Miguel O.; Mereles, Alberto Perez; Tamashiro, Gustavo A.; Dini, Andres E.; Mollon, Ana P.; De Candido, Laura V.; Zelaya, Denis A.; Soledispa-Suarez, Carlos I.; Denato, Sergio; Tamashiro, Alberto; Diaz, Jose A., E-mail: joseantoniodiaz@hotmail.com [Hospital Nacional Prof. Alejandro Posadas, Department of Cardiology, Section of Hemodinamia (Argentina)

    2013-04-15

    We report a rare case of a tuberculous mycotic aortoiliac pseudoaneurysm treated with an endovascular procedure and follow-up of 36 months. The patient was a white 72-year-old man with pulmonary tuberculosis and a former smoker with hypertension, chronic renal failure, and dyslipidemia. A computed tomographic scan of the abdomen and pelvis revealed a left paravertebral cavity with fluid content and involvement of vertebrae L2-L4. After a surgical repair attempt, the patient was treated with the implant of a bifurcated endoprosthesis. Because it is unlikely that any center has extensive experience in the management of this rare manifestation of the disease, we reviewed the literature for similar cases.

  17. Endovascular management of delayed post-pancreatectomy haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Pottier, Edwige [Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Department of Radiology, Clichy, Hauts-de-Seine (France); Ronot, Maxime; Vilgrain, Valerie [Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Department of Radiology, Clichy, Hauts-de-Seine (France); University Paris Diderot, Paris (France); INSERM U1149, centre de recherche biomedicale Bichat-Beaujon, CRB3, Paris (France); Gaujoux, Sebastien; Cesaretti, Manuela; Barbier, Louise [APHP, University Hospitals Paris Nord Val de Seine, Beaujon, Department of Surgery, Clichy, Hauts-de-Seine (France); Sauvanet, Alain [University Paris Diderot, Paris (France); APHP, University Hospitals Paris Nord Val de Seine, Beaujon, Department of Surgery, Clichy, Hauts-de-Seine (France)

    2016-10-15

    To assess the patient outcome after endovascular treatment of delayed post-pancreatectomy haemorrhage (PPH) as first-line treatment. Between January 2005 and November 2013, all consecutive patients referred for endovascular treatment of PPH were included. Active bleeding, pseudoaneurysms, collections and the involved artery were recorded on pretreatment CT. Endovascular procedures were classified as technical success (source of bleeding identified on angiogram and treated), technical failure (source of bleeding identified but incompletely treated) and abstention (no abnormality identified, no treatment performed). Factors associated with rebleeding were analysed. Sixty-nine patients (53 men) were included (mean 59 years old (32-75)). Pretreatment CT showed 27 (39 %) active bleeding. In 22 (32 %) cases, no involved artery was identified. Technical success, failure and abstention were observed in 48 (70 %), 9 (13 %) and 12 patients (17 %), respectively. Thirty patients (43 %) experienced rebleeding. Rebleeding rates were 29 %, 58 % and 100 % in case of success, abstention and failure (p < 0.001). Treatment failure/abstention was the only factor associated with rebleeding. Overall, 74 % of the patients were successfully treated by endovascular procedure(s) alone. After a first endovascular procedure for PPH, the rebleeding rate is high and depends upon the success of the procedure. Most patients are successfully treated by endovascular approach(es) alone. (orig.)

  18. Endovascular management of delayed post-pancreatectomy haemorrhage

    International Nuclear Information System (INIS)

    Pottier, Edwige; Ronot, Maxime; Vilgrain, Valerie; Gaujoux, Sebastien; Cesaretti, Manuela; Barbier, Louise; Sauvanet, Alain

    2016-01-01

    To assess the patient outcome after endovascular treatment of delayed post-pancreatectomy haemorrhage (PPH) as first-line treatment. Between January 2005 and November 2013, all consecutive patients referred for endovascular treatment of PPH were included. Active bleeding, pseudoaneurysms, collections and the involved artery were recorded on pretreatment CT. Endovascular procedures were classified as technical success (source of bleeding identified on angiogram and treated), technical failure (source of bleeding identified but incompletely treated) and abstention (no abnormality identified, no treatment performed). Factors associated with rebleeding were analysed. Sixty-nine patients (53 men) were included (mean 59 years old (32-75)). Pretreatment CT showed 27 (39 %) active bleeding. In 22 (32 %) cases, no involved artery was identified. Technical success, failure and abstention were observed in 48 (70 %), 9 (13 %) and 12 patients (17 %), respectively. Thirty patients (43 %) experienced rebleeding. Rebleeding rates were 29 %, 58 % and 100 % in case of success, abstention and failure (p < 0.001). Treatment failure/abstention was the only factor associated with rebleeding. Overall, 74 % of the patients were successfully treated by endovascular procedure(s) alone. After a first endovascular procedure for PPH, the rebleeding rate is high and depends upon the success of the procedure. Most patients are successfully treated by endovascular approach(es) alone. (orig.)

  19. A Close Cut: A Technical Report of Endovascular Removal of a Penetrating Intravascular Foreign Body after a Lawn Mowing Injury

    Energy Technology Data Exchange (ETDEWEB)

    Tapping, C. R. [Oxford University Hospitals, John Radcliffe Hospital, Department of Radiology (United Kingdom); Gallo, A.; Silva, R. J. De [Oxford University Hospitals, John Radcliffe Hospital, Department of Cardiothoracic Surgery (United Kingdom); Uberoi, R., E-mail: raman.uberoi@orh.nhs.uk [Oxford University Hospitals, John Radcliffe Hospital, Department of Radiology (United Kingdom)

    2012-12-15

    We present a case of endovascular retrieval of a penetrating foreign body that was originally lodged in the mediastinum and then migrated to the hepatic vein. The steel nail entered the thorax and traversed the left lung causing a pneumothorax. The patient underwent a thoracotomy, but the foreign body had migrated from its original mediastinal position. A postsurgical CT showed that the object was below the right hemidiaphragm. Diagnostic venogram demonstrated that the object was in the main hepatic vein. Using a double-snare technique, the object was safely and successfully removed from the hepatic vein via the right common femoral vein.

  20. “ELEPHANT TRUNK” AND ENDOVASCULAR STENTGRAFTING – A HYBRID APPROACH TO THE TREATMENT OF EXTENSIVE THORACIC AORTIC ANEURYSM

    Directory of Open Access Journals (Sweden)

    Tomáš Holubec

    2013-01-01

    Full Text Available A hybrid approach to elephant trunk technique for treatment of thoracic aortic aneurysms combines a conventional surgical and endovascular therapy. Compared to surgery alone, there is a presumption that mortality and morbidity is reduced. We present a case report of a 42-year-old man with a giant aneurysm of the entire thoracic aorta, significant aortic and tricuspid regurgitation and ventricular septum defect. The patient underwent multiple consecutive operations and interventions having, among others, finally replaced the entire thoracic aorta with the use of the hybrid elephant trunk technique.

  1. Anesthesia Approach in Endovascular Aortic Reconstruction

    Directory of Open Access Journals (Sweden)

    Ayşin Alagöl

    2013-03-01

    Full Text Available Introduction: We have analyzed our initial results of our anesthesia techniques in our new-onset endovascular aortic reconstruction cases.Patients and Methods: The perioperative data of 15 elective and emergent endovascular aortic reconstruction cases that were operated in 2010-2011 were collected in a database. The choice of anesthesia was made by the risk factors, surgical team’s preferences, type and location of the aortic pathology and by the predicted operation duration. The data of local and general anesthesia cases were compared.Results: Thirteen (86.7% cases were male and 2 (13.3% female. Eleven patients were in ASA Class III. The demographic parameters, ASA classifications, concurrent diseases were similar in both groups. Thirteen (86.7% cases had infrarenal abdominal aortic aneurysm and 2 (13.3% had Type III aortic dissection. The diastolic arterial pressures were lower in general anesthesia group in 20th and 40th minutes’ measurements just like the mean arterial pressure measurements at the 40th, 100th minutes and during the deployment of the graft. Postoperative mortality occurred in 3 (20.0% patients and they all had general anesthesia and they were operated on emergency basis. Postoperative morbidity occurred in four patients that had general anesthesia (acute renal failure, multi-organ failure and pneumonia. The other patient had atrial fibrillation on the 1st postoperative day and was converted to sinus rhythm with amiodarone infusion.Conclusion: Edovascular aortic reconstruction procedures can safely be performed with both general and local anesthesia less invasively compared to open surgery. General anesthesia may be preferred for the better hemodynamic control.

  2. Microneurosurgery in combination with endovascular embolisation in the treatment of solid haemangioblastoma in the dorsal medulla oblongata.

    Science.gov (United States)

    Wu, Pengfei; Liang, Chuansheng; Wang, Yunjie; Guo, Zongze; Li, Bo; Qiu, Bo; Li, Xinguo; Wen, Zhifeng; Pan, Qichen

    2013-06-01

    To investigate the treatment of solid haemangioblastomas in the dorsal medulla oblongata using microneurosurgery in combination with endovascular embolisation. Clinical data from 11 patients with solid haemangioblastomas in the dorsal medulla oblongata who were treated with endovascular embolisation followed by microneurosurgery were analysed retrospectively. Clinical results were evaluated using the modified Rankin scale. The patients were preoperatively evaluated by neuroimaging methods such as magnetic resonance imaging (MRI), contrast MRI and digital subtraction angiography (DSA). General anaesthesia was induced, the patients were tracheally intubated, and the abnormal vessels were embolised. Surgery to resect the haemangioblastoma was conducted after the blood-clotting index returned to normal levels (generally one month after the interventional treatment). Embolisation was accomplished in all 11 patients. DSA analysis revealed that most of the tumour vessels and tumour stains disappeared without any complications. The haemangioblastomas were completely resected. None of the patients received blood transfusion or died during surgery. The neurological deficit was reduced or eliminated in 10 patients, but 1 patient died after experiencing an acute myocardial infarction on the tenth postoperative day. No recurrence occurred during follow-up in patients who underwent total tumour resection. Postoperative grades using the modified Rankin scale were improved in all 10 patients. However, several complications occurred, including communicating hydrocephalus, incision infection, pneumonia and cerebrospinal fluid leakage from the incision. Notably, normal perfusion pressure breakthrough (NPPB) did not develop during or after endovascular embolisation or surgery. Preoperative endovascular embolisation is a safe and effective adjunct treatment. Employing this treatment, solid haemangioblastomas in the dorsal medulla oblongata can be safely and completely resected

  3. Transthoracic Echocardiography Provides Important Long-Term Prognostic Information in Selected Patients Undergoing Endovascular Abdominal Aortic Repair.

    Science.gov (United States)

    O'Driscoll, Jamie M; Bahia, Sandeep S; Gravina, Angela; Di Fino, Sara; Thompson, Matthew M; Karthikesalingam, Alan; Holt, Peter J E; Sharma, Rajan

    2016-02-01

    The value of performing transthoracic echocardiography (TTE) as part of the clinical assessment of patients awaiting endovascular repair of the abdominal aorta is little evaluated. We aimed to estimate the prognostic importance of information derived from TTE on long-term all-cause mortality in a selected group of patients undergoing endovascular aneurysm repair. This was a retrospective cohort study of 273 consecutive patients selected for endovascular aneurysm repair. All patients included in the analysis underwent TTE before their procedure. Multivariable Cox regression analysis was used to estimate the effect of TTE measures on all-cause mortality. Over a mean follow-up of 3.2±1.5 years, there were 78 deaths with a mean time to death of 1.28±1.16 years. A greater tubular ascending aorta (hazard ratio [HR] 5.6, 95% confidence interval [CI] 2.77-11.33), presence of mitral regurgitation (HR 8.13, 95% CI 4.09-12.16), lower left ventricular ejection fraction (HR 0.96, 95% CI 0.93-0.98), younger age (HR 0.97, 95% CI 0.95-0.99), and presence of diabetes mellitus (HR 1.46, 95% CI 1.24-1.89) were predictors of all-cause mortality. Echocardiography provides important long-term prognostic information in patients undergoing endovascular aneurysm repair. These TTE indices were more important at predicting outcome than standard conventional risk factors in this patient group. A greater tubular ascending aorta, presence of mitral regurgitation, reduced left ventricular ejection fraction, younger age, and diabetes mellitus were independently associated with long-term mortality. © 2016 American Heart Association, Inc.

  4. Management of stenosis lesions during the period of endovascular treatment for acute ischemic stroke

    Directory of Open Access Journals (Sweden)

    Hong-xing HAN

    2017-11-01

    Full Text Available Objective To investigate the management of stenosis lesions during endovascular treatment for acute ischemic stroke. Methods A total of 36 acute ischemic stroke patients combined with intracranial/extracranial arterial stenosis were treated with endovascular treatment or bridging treatment. Time from aggravation on admission or in hospital stay to femoral artery puncture, from femoral arterypuncture to recanalization were recorded. Modified Thrombolysis in Cerebral Infarction (mTICI was usedto assess the recanalization immediately after operation. Modified Rankin Scale (mRS was used to evaluate prognosis at 90 d after operation. Occurrence rate of symptomatic intracranial hemorrhage and mortality were recorded. Results Among 36 patients, 13 patients (36.11% underwent intravenous thrombolysis and then endovascular thrombectomy. In all patients, there were 21 (58.33% with intracranial stenosis and 15 (41.67% with extracranial stenosis, 16 (44.44% with anterior circulation stenosis and 20 (55.56% with posterior circulation stenosis. Stent thrombectomy was used in 25 patients (69.44% , while balloon dilatation and/or stent implantation was used in 11 patients (30.56% . For 21 patients with intracranial arterial stenosis, 4 were treated with balloon dilatation only, 9 with Wingspan self-expandable stents and 8 with Apollo balloon-expandable stents. Fifteen patients with extracranial arterial stenosis were treated with balloon dilatation and stent implantation. A total of 33 patients (91.67% achieved recanalization (mTICI 2b-3 grade, 21 patients (58.33% had good outcomes (mRS ≤ 2 score, while symptomatic intracranial hemorrhage occurred in 2 patients (5.56% and 5 (13.89% died. There were no statistically significant differences in the rate of good prognosis, symptomatic intracranial hemorrhage and mortality between intracranial and extracranial arterial stenosis, anterior and posterior circulation stenosis (Fisher exact probability: P > 0.05, for

  5. Early experience with transfemoral endovascular aneurysm management (TEAM) in the treatment of aortic aneurysms

    NARCIS (Netherlands)

    Balm, R.; Eikelboom, B. C.; May, J.; Bell, P. R.; Swedenborg, J.; Collin, J.

    1996-01-01

    OBJECTIVES: To evaluate the early experience with transfemoral endovascular aortic aneurysm management using the Endovascular Grafting System. DESIGN: Multi-centre prospective evaluation of the implantation procedure and early results (median follow-up 153 days). SETTING: Department of Surgery,

  6. Fatal late multiple emboli after endovascular treatment of abdominal aortic aneurysm. Case report

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Sandermann, Jes; Bruun-Petersen, J

    1998-01-01

    The short term experience of endovascular treatment of abdominal aortic aneurysms (AAA) seems