WorldWideScience

Sample records for underwent endovascular stent-graft

  1. Endovascular stent grafting: a review

    International Nuclear Information System (INIS)

    Kribs, S.

    2001-01-01

    Endovascular stent grafts are intravascular devices composed of surgical graft material and a metallic frame, (Fig. 1). Their main application has been to treat aneurysms, but they have been used in vascular trauma and are being investigated for use in occlusive disease. Their advantage in treating aneurysms over conventional surgical treatment is that they are loaded into relatively small delivery systems (Fig. 2) and can be introduced to the area of interest from a remote site - usually the femoral artery. This avoids the morbidity of surgical exposure in difficult sites, such as the thoracic aorta, and lessens the cardiovascular stress to patients by eliminating the need to surgically cross-clamp the vessel being treated. The first description of abdominal aortic aneurysm exclusion by an endovascular stent graft was provided by Parodi and colleagues in 1991. Much of the early clinical experience in endovascular stent grafting was obtained from centres in Australia and Europe, and they are now reporting midterm follow-up data. There are now many centres in Canada and the United States involved in endovascular research and practice. (author)

  2. 3D printing guiding stent graft fenestration: A novel technique for fenestration in endovascular aneurysm repair.

    Science.gov (United States)

    Huang, Jianhua; Li, Gan; Wang, Wei; Wu, Keming; Le, Tianming

    2017-08-01

    Objective To describe a novel approach, 3D printing guiding stent graft fenestration, for fenestration during endovascular aneurysm repair for juxtarenal abdominal aortic aneurysm. Methods A 69-year-old male with juxtarenal abdominal aortic aneurysm underwent endovascular aneurysm repair with "off the label" fenestrated stent graft. To precisely locate the fenestration position, we reconstructed a 3D digital abdominal aortic aneurysm model and created a skin template covering this abdominal aortic aneurysm model. Then the skin template was physically printed and the position of the visceral vessel was hollowed out, thereby helping in locating the fenestration on stent graft. Results and conclusions With the help of this 3D printed skin template, we fenestrated the stent graft accurately and rebuilt the bilateral renal artery successfully. This is the first clinical case that used 3D printing guiding stent graft fenestration, which is a novel approach for precise fenestration on stent graft on the table during endovascular aneurysm repair.

  3. CASE REPORT CASE CASE Endovascular stent grafting of ...

    African Journals Online (AJOL)

    Endovascular stent graft repair for the treatment of post-traumatic aortic rupture is emerging as a safe, ... motor vehicle accidents; of all patients sustaining such injury, 85% will die before reaching hospital. Fifty per cent of the ... to undertake an endovascular repair of the thoracic pseudo-aneurysm. Endovascular procedure.

  4. [Endovascular stent-grafting for mycotic thoracic aortic aneurysm].

    Science.gov (United States)

    Okada, S; Kaneko, T; Ezure, M; Satoh, Y; Hasegawa, Y; Koike, N; Okonogi, S; Takihara, H

    2009-02-01

    We report 3 cases of endovascular stent-grafting (ESG) for mycotic thoracic aortic aneurysm. The case 1 was a rupture of pseudoaneurysm of the descending aorta caused by mediastinitis due to perforation of esophageal ulcer. The patient underwent emergent ESG for temporary control of the rupture. He underwent esophagus reconstruction 5 month after ESG. The case 2 was admitted due to inflammatory reaction. She was diagnosed with mycotic descending aortic aneurysm and underwent elective ESG because of her old age. Her postoperative course was uneventful and no infection recurred. The case 3 underwent ESG for a ruptured mycotic descending aortic aneurysm. But 113 days after ESG, he underwent ESG again for a ruptured endoleak of the stentgraft. His blood culture demonstrated methillin-resistant Staphylococcus aureus (MRSA). He died of rupture to bronchus and esophagus at 18th day after ESG. We believe that ESG is useful in high risk patients for temporary management of the rupture.

  5. Modification of an endovascular stent graft for abdominal aortic aneurysm

    Science.gov (United States)

    Moloye, Olajompo Busola

    Endovascular surgery is currently used to treat abdominal aortic aneurysms (AAA). A stent graft is deployed to exclude blood flow from the aneurysm sac. It is an effective procedure used in preventing aneurysm rupture, with reduced patient morbidity and mortality compared to open surgical repair. Migration and leakage around the device ("endoleak") due to poor sealing of the stent graft to the aorta have raised concerns about the long-term durability of endovascular repair. A preliminary study of cell migration and proliferation is presented as a prelude to a more extensive in vivo testing. A method to enhance the biological seal between the stent graft and the aorta is proposed to eliminate this problem. This can be achieved by impregnating the stent graft with 50/50 poly (DL-lactide co glycolic acid) (PLGA) and growth factors such as basic fibroblast growth factor (bFGF) or connective tissue growth factor (CTGF), at the proximal and distal ends. It is hypothesized that as PLGA degrades it will release the growth factors that will promote proliferation and migration of aortic smooth muscle cells to the coated site, leading to a natural seal between the aorta and the stent graft. In addition, growth factor release should promote smooth muscle cell (SMC) contraction that will help keep the stent graft in place at the proximal and distal ends. It is shown that a statistically significant effect of increased cell proliferation and migration is observed for CTGF release. Less of an effect is noted for bFGF or just the PLGA. The effect is estimated to be large enough to be clinically significant in a future animal study. The long term goal of this study is to reduce migration encounter after graft deployment and to reduce secondary interventions of EVAR especially for older patients who are unfit for open surgical treatment.

  6. Endovascular stent graft treatment of acute thoracic aortic transections due to blunt force trauma.

    LENUS (Irish Health Repository)

    Bjurlin, Marc A

    2012-02-01

    Endovascular stent graft treatment of acute thoracic aortic transections is an encouraging minimally invasive alternative to open surgical repair. Between 2006 and 2008, 16 patients with acute thoracic aortic transections underwent evaluation at our institution. Seven patients who were treated with an endovascular stent graft were reviewed. The mean Glasgow Coma Score was 13.0, probability of survival was .89, and median injury severity score was 32. The mean number of intensive care unit days was 7.7, mean number of ventilator support days was 5.4, and hospital length of stay was 10 days. Mean blood loss was 285 mL, and operative time was 143 minutes. Overall mortality was 14%. Procedure complications were a bleeding arteriotomy site and an endoleak. Endovascular treatment of traumatic thoracic aortic transections appears to demonstrate superior results with respect to mortality, blood loss, operative time, paraplegia, and procedure-related complications when compared with open surgical repair literature.

  7. Endovascular tubular stent-graft placement for isolated iliac artery aneurysms.

    Science.gov (United States)

    Okada, Takuya; Yamaguchi, Masato; Kitagawa, Atsushi; Kawasaki, Ryota; Nomura, Yoshikatsu; Okita, Yutaka; Sugimura, Kazuro; Sugimoto, Koji

    2012-02-01

    To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non-contrast-enhanced CT was performed in seven patients with chronic kidney disease. All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47-2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.

  8. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  9. Long-term Results of Endovascular Stent Graft Placement of Ureteroarterial Fistula

    International Nuclear Information System (INIS)

    Okada, Takuya; Yamaguchi, Masato; Muradi, Akhmadu; Nomura, Yoshikatsu; Uotani, Kensuke; Idoguchi, Koji; Miyamoto, Naokazu; Kawasaki, Ryota; Taniguchi, Takanori; Okita, Yutaka; Sugimoto, Koji

    2013-01-01

    PurposeTo evaluate the safety, efficacy, and long-term results of endovascular stent graft placement for ureteroarterial fistula (UAF).MethodsWe retrospectively analyzed stent graft placement for UAF performed at our institution from 2004 to 2012. Fistula location was assessed by contrast-enhanced computed tomography (CT) and angiography, and freedom from hematuria recurrence and mortality rates were estimated.ResultsStent graft placement for 11 UAFs was performed (4 men, mean age 72.8 ± 11.6 years). Some risk factors were present, including long-term ureteral stenting in 10 (91 %), pelvic surgery in 8 (73 %), and pelvic radiation in 5 (45 %). Contrast-enhanced CT and/or angiography revealed fistula or encasement of the artery in 6 cases (55 %). In the remaining 5 (45 %), angiography revealed no abnormality, and the suspected fistula site was at the crossing area between urinary tract and artery. All procedures were successful. However, one patient died of urosepsis 37 days after the procedure. At a mean follow-up of 548 (range 35–1,386) days, 4 patients (36 %) had recurrent hematuria, and two of them underwent additional treatment with secondary stent graft placement and surgical reconstruction. The hematuria recurrence-free rates at 1 and 2 years were 76.2 and 40.6 %, respectively. The freedom from UAF-related and overall mortality rates at 2 years were 85.7 and 54.9 %, respectively.ConclusionEndovascular stent graft placement for UAF is a safe and effective method to manage acute events. However, the hematuria recurrence rate remains high. A further study of long-term results in larger number of patients is necessary

  10. Transcarotid Artery Endovascular Reconstruction of the Aortic Arch by Modified Bifurcated Stent Graft for Stanford Type A Dissection

    Directory of Open Access Journals (Sweden)

    Wei Guo

    2007-10-01

    Full Text Available A 40-year-old man with Stanford type B dissection underwent his first endovascular repair (EVAR in April 2004 by Talent thoracic stent graft. He had an uncomplicated recovery and maintained good blood pressure control. However, a new retrograde dissection appeared in September 2004. The new dissection involved his aortic arch and ascending thoracic aorta to the opening of the coronary arteries. To reconstruct the aortic arch, bypasses between the right common carotid artery (RCCA, left common carotid artery and left subclavian artery were performed before endovascular repair. A modified bifurcated Talent stent graft was deployed from the RCCA to the ascending thoracic aorta with a long limb in the innominate artery and a short limb in the aortic arch. A further two pieces of graft were deployed via the common femoral artery. The ascending thoracic aorta and aortic arch were reconstructed completely by the bifurcated stent graft. The final angiography confirmed that there was good stent graft configuration, normal blood flow, and stable haemodynamics. No endoleak or other major complications were encountered. This result indicated that it is possible to reconstruct the aortic arch with a bifurcated stent graft and could be a new endovascular repair model for complex thoracic aortic aneurysm and dissection.

  11. Contrast Medium Induced Nephropathy after Endovascular Stent Graft Placement: An Examination of Its Prevalence and Risk Factors

    International Nuclear Information System (INIS)

    Kawatani, Yohei; Nakamura, Yoshitsugu; Mochida, Yoshihiko; Yamauchi, Naoya; Hayashi, Yujiro; Taneichi, Tetsuyoshi; Ito, Yujiro; Kurobe, Hirotsugu; Suda, Yuji; Hori, Takaki

    2016-01-01

    Endovascular stent graft placement has become a major treatment for thoracic and abdominal aneurysms. While endovascular therapy is less invasive than open surgery, it involves the use of a contrast medium. Contrast media can cause renal impairment, a condition termed as contrast-induced nephropathy (CIN). This study sought to evaluate the incidence and risk factors of CIN following endovascular stent graft placement for aortic aneurysm repair. The study included 167 consecutive patients who underwent endovascular stent graft placement in our hospital from October 2013 to June 2014. CIN was diagnosed using the European Society of Urogenital Radiology criteria. Patients with and without CIN were compared. Chi-squared tests, t-tests, and multivariate logistic regression analyses were performed. Thirteen patients (7.8%) developed CIN. Left ventricular dysfunction and intraoperative blood transfusion were significantly more frequent in the CIN group (P = 0.017 and P = 0.032, resp.). Multivariate analysis showed that left ventricular dysfunction had the strongest influence on CIN development (odds ratio 9.34, P = 0.018, and 95% CI = 1.46–59.7). Patients with CIN also experienced longer ICU and hospital stays. Measures to improve renal perfusion flow should be considered for patients with left ventricular dysfunction who are undergoing endovascular stent graft placement

  12. Endovascular Exclusion of Abdominal Aortic Aneurysms: Initial Experience with Stent-Grafts in Cardiology Practice

    OpenAIRE

    Howell, Marcus H.; Zaqqa, Munir; Villareal, Rollo P.; Strickman, Neil E.; Krajcer, Zvonimir

    2000-01-01

    The use of an endovascular stent-graft prosthesis for the treatment of infrarenal abdominal aortic aneurysms is receiving increasing attention as an option that may avoid the significant morbidity and mortality associated with open surgical treatment. We studied the clinical effectiveness of stent-grafts in patients with infrarenal abdominal aortic aneurysms.

  13. The midterm experience of tapered stent grafts in the endovascular management of iliac artery aneurysms with unfavorable anatomy.

    Science.gov (United States)

    Aldin, Zaid; Kashef, Elika; Jenkins, Michael; Gibbs, Richard; Wolfe, John; Hamady, Mohamad

    2012-02-01

    We report our experience and the midterm results of a modern technique for endovascular management of isolated iliac artery aneurysms (IAAs) with unfavorable neck anatomy, which involves the inversion of an iliac leg of a Zenith stent graft. Patients who underwent endovascular IAA repair from 2002 to 2010 were reviewed. A total of 12 patients, with a mean age of 77.6 years, underwent endovascular repair of 13 IAAs. Mean size of the aneurysms was 54.6 mm (range 34-133 mm). Mean proximal neck diameter was 18 mm (range 15-22 mm). In 7 patients, the length of the proximal neck was <15 mm (10-14 mm). Only 1 patient developed thrombosis of the stent graft immediately after the operation. Patients were followed up for a mean of 31.5 months (range 18-72 months). Our midterm results demonstrate the durability of this technique in the management of iliac aneurysms with unfavorable anatomy.

  14. Endovascular treatment of aneurysm of splenic artery arising from splenomesentric trunk using stent graft

    Energy Technology Data Exchange (ETDEWEB)

    Kulkami, Chinmay Bhimaji; Moorthy Srikanth; Pullara Sreekumar Karumathil; Kannan, Rajesh Ramaih [Department of Radiology, Amrita Institute of Medical Sciences, Amrita Lane (India)

    2013-12-15

    We report a rare case of aneurysm of splenic artery arising anomalously from the superior mesenteric artery (SMA). The aneurysm was treated successfully by coil embolization of the splenic artery distal to aneurysm and then deploying a stent graft in the SMA. A combination of stent graft and coil embolization for the treatment of aberrant splenic artery aneurysm has been reported only once. We describe the imaging findings and the endovascular procedure in this patient.

  15. Clinical Aspects on Chimney Stent Graft Technique in Endovascular Repair of the Aorta.

    OpenAIRE

    BinJabr, Adel

    2015-01-01

    Introduction: Open repair of the aorta carries a high risk for morbidity and mortality especially in the elderly population and in patients unfit for major surgery. Endovascular aortic repair is safe, durable and effective when there is adequate proximal and distal sealing zone for the aortic stent graft. Fenestrated and branched stent grafts have made the repair possible for complex but elective cases that do not have an adequate sealing zone. Urgent complex cases and patients with midaortic...

  16. Endovascular treatment of isolated common iliac artery aneurysms with short necks using bifurcated stent-grafts.

    Science.gov (United States)

    Wi, Jin; Ko, Young-Guk; Kim, Jung-Sun; Choi, Donghoon; Hong, Myeong-Ki; Lee, Do-Youn; Jang, Yangsoo; Shim, Won-Heum

    2010-07-01

    Elective surgical repair has traditionally been considered to be the treatment of choice for the exclusion of isolated iliac artery aneurysms (IAAs). Recently, endovascular repair has evolved as an alternative to surgical repair, especially in patients at high surgical risk. However, in the absence of sufficient proximal necks, iliac artery aneurysms are not suitable for direct deployment of a tubular-shaped endograft. Here we report two cases of IAAs with short proximal necks that were excluded using an endovascular bifurcated stent-graft. The bifurcated stent-graft was successfully deployed with complete exclusion of the aneurysm. In neither case was there evidence of procedural failures. There were no signs of significant complications. We conclude that endovascular repair of IAAs with short proximal necks is feasible and efficient using an endovascular bifurcated stent-graft.

  17. MDCT angiography of thoracic aorta endovascular stent-grafts: pearls and pitfalls.

    Science.gov (United States)

    Hoang, Jenny K; Martinez, Santiago; Hurwitz, Lynne M

    2009-02-01

    The objective of our study was to review expected findings and complications after thoracic endovascular aortic repair on CT angiography (CTA). Luminal and extraluminal changes to the thoracic aorta occur after endovascular stent-grafting. The radiologist can facilitate appropriate management by detecting and differentiating expected CTA findings from complications.

  18. Endovascular treatment of isolated iliac artery aneurysms with anaconda stent graft limb.

    Science.gov (United States)

    Karathanos, Christos; Kaperonis, Elias; Xanthopoulos, Dimitrios; Konstantopoulos, Theophanis; Exarchou, Maria; Loupou, Caterini; Papavassiliou, Vassilios

    2013-01-01

    Isolated aneurysms of the iliac arteries are relatively rare conditions that traditionally have been treated by surgical reconstruction. We report our experience with endovascular treatment of iliac artery aneurysms (IAAs) with Anaconda stent graft limb. Two male patients were found to have 4.5 and 3.6 cm isolated common IAAs, respectively. The endograft was successfully advanced and deployed precisely to the intended position in both cases. In one case the internal iliac artery was embolized. No type I or II endoleak was observed immediately after the procedure. In one patient postimplantation fever (>38°C) and gluteal claudication occurred. After 2 years followup both iliac endovascular stent grafts are patent and without endoleak. Endovascular treatment with Anaconda limb stent graft seems to be a safe and feasible alternative to open surgery.

  19. Endovascular Treatment of Isolated Iliac Artery Aneurysms with Anaconda Stent Graft Limb

    Directory of Open Access Journals (Sweden)

    Christos Karathanos

    2013-01-01

    Full Text Available Isolated aneurysms of the iliac arteries are relatively rare conditions that traditionally have been treated by surgical reconstruction. We report our experience with endovascular treatment of iliac artery aneurysms (IAAs with Anaconda stent graft limb. Two male patients were found to have 4.5 and 3.6 cm isolated common IAAs, respectively. The endograft was successfully advanced and deployed precisely to the intended position in both cases. In one case the internal iliac artery was embolized. No type I or II endoleak was observed immediately after the procedure. In one patient postimplantation fever (>38°C and gluteal claudication occurred. After 2 years followup both iliac endovascular stent grafts are patent and without endoleak. Endovascular treatment with Anaconda limb stent graft seems to be a safe and feasible alternative to open surgery.

  20. Endovascular stent grafting of thoracic aortic aneurysms: technological advancements provide an alternative to traditional surgical repair.

    Science.gov (United States)

    Jones, Lauren E Beste

    2005-01-01

    The use of endovascular stent grafts is a leading technological advancement in the treatment of thoracic aortic aneurysms, and is being trialed in the United States as an alternative to medical management and traditional surgical repair. Aortic stent grafts, initially used only for abdominal aortic aneurysms, have been used for over 10 years in Europe and are currently under United States Food and Drug Administration investigation for the treatment of chronic and acute aortic aneurysms. Diseases of the thoracic aorta are often present in high-risk individuals, and, as a result, there is a high morbidity and mortality rate associated with both medical and surgical management of these patients. The development and refinement of endovascular approaches have the potential to decrease the need for traditional surgical repair, especially in high-risk populations such as the elderly and those with multiple comorbidities. Endovascular technology for thoracic repair has only been used in Europe for the last 10 years, with no long-term outcomes available; however, preliminary research demonstrates favorable early and midterm outcomes showing that endovascular stent graft placement to exclude the dilated, dissected, or ruptured aorta is both technically feasible and safe for patients. The article highlights the historical perspective of endovascular stent grafting as well as a description of patient selection, the operative procedure, benefits, risks, and unresolved issues pertaining to the procedure. A brief review of aneurysm and dissection pathophysiology and management is provided, as well as postoperative management for acute care nurses and recommendations for clinical practice.

  1. Endovascular stent graft repair for thoracic aortic aneurysms: the history and the present in Japan.

    Science.gov (United States)

    Kawaguchi, Satoshi; Shimizu, Hideyuki; Yoshitake, Akihiro; Shimazaki, Taro; Iwahashi, Toru; Ogino, Hitoshi; Ishimaru, Shin; Shigematsu, Hiroshi; Yozu, Ryohei

    2013-01-01

    Stent-grafts for endovascular repair of thoracic aortic aneurysms have been commercially available for more than ten years in the West, whereas, in Japan, a manufactured stent-graft was not approved for the use until March 2008. Nevertheless, endovascular thoracic intervention began to be performed in Japan in the early 1990s, with homemade devices used in most cases. Many researchers have continued to develop their homemade devices. We have participated in joint design and assessment efforts with a stent-graft manufacturer, focusing primarily on fenestrated stent-grafts used in repairs at the distal arch, a site especially prone to aneurysm. In March 2008, TAG (W.L. Gore & Associates, Inc., Flagstaff, Arizona, USA) was approved as a stent graft for the thoracic area first in Japan, which was major turning point in treatment for thoracic aortic aneurysms. Subsequently, TALENT (Medtronic, Inc., Minneapolis, Minnesota, USA) was approved in May 2009, and TX2 (COOK MEDICAL Inc., Bloomington, Indiana, USA) in March 2011. Valiant as an improved version of TALENT was approved in November 2011, and TX2 Proform as an improved version of TX2 began to be supplied in October 2012. These stent grafts are excellent devices that showed good results in Western countries, and marked effectiveness can be expected by making the most of the characteristics of each device. A clinical trial in Japan on Najuta (tentative name) (Kawasumi Labo., Inc., Tokyo, Japan) as a line-up of fenestrated stent grafts that can be applied to distal arch aneurysms showing a high incidence, and allow maintenance of blood flow to the arch vessel was initiated. This trial was completed, and Najuta has just been approved in January of 2013 in Japan, and further development is expected. In the U.S., great efforts have recently been made to develop and manufacture excellent stent grafts for thoracic aneurysms, and rapid progress has been achieved. In particular, in the area of the aortic arch, in which we

  2. Endovascular Stent Grafting for Aortic Arch Aneurysm in Aortoiliac Occlusive Disease following Aortic Arch Debranching and Aortobifemoral Reconstruction

    Directory of Open Access Journals (Sweden)

    Didem Melis Oztas

    2017-01-01

    Full Text Available Treatment of thoracic aortic aneurysms constitutes high mortality and morbidity rates despite improvements in surgery, anesthesia, and technology. Endovascular stent grafting may be an alternative therapy with lower risks when compared with conventional techniques. However, sometimes the branches of the aortic arch may require transport to the proximal segments prior to successful thoracic aortic endovascular stent grafting. Atherosclerosis is accounted among the etiology of both aneurysms and occlusive diseases that can coexist in the same patient. In these situations stent grafting may even be more complicated. In this report, we present the treatment of a 92-year-old patient with aortic arch aneurysm and proximal descending aortic aneurysm. For successful thoracic endovascular stent grafting, the patient needed an alternative route other than the native femoral and iliac arteries for the deployment of the stent graft. In addition, debranching of left carotid and subclavian arteries from the aortic arch was also required for successful exclusion of the thoracic aneurysm.

  3. Endovascular stent graft for treatment of complicated spontaneous dissection of celiac artery: Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ung Rae; Lee, Young Hwan [Dept. of Diagnostic Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Hwan [Dept. of Diagnostic Radiology, Dongsan Medical Center, Keimyung University School of Medicine, Daegu (Korea, Republic of)

    2013-06-15

    We report 2 cases of complicated spontaneous dissection of the celiac artery, which were successfully treated by a stent graft. The first patient was a 47-year-old man who presented with acute abdominal pain. CT scan showed ruptured saccular aneurysm with surrounding retroperitoneal hematoma. The second patient was a 57-year-old man with progressive dissecting aneurysm. Endovascular stent graft was placed in the celiac trunk to control bleeding, and to prevent rupture in each patient. Follow-up CT scans showed complete obliteration of a dissecting aneurysm.

  4. Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration?

    Science.gov (United States)

    Malina, M; Lindblad, B; Ivancev, K; Lindh, M; Malina, J; Brunkwall, J

    1998-11-01

    To investigate if stents with hooks and barbs will improve stent-graft fixation in the abdominal aorta. Sixteen- to 24-mm-diameter Dacron grafts were deployed inside cadaveric aortas. The grafts were anchored by stents as in endovascular abdominal aortic aneurysm repair. One hundred thirty-seven stent-graft deployments were carried out with modified self-expanding Z-stents with (A) no hooks and barbs (n = 75), (B) 4 5-mm-long hooks and barbs (n = 39), (C) 8 10-mm-long, strengthened hooks and barbs (n = 19), or (D) hooks only (n = 4). Increasing longitudinal traction was applied to determine the displacement force needed to extract the stent-grafts. The radial force of the stents was measured and correlated to the displacement force. The median (interquartile range) displacement force needed to extract grafts anchored by stent A was 2.5 N (2.0 to 3.4), stent B 7.8 N (7.4 to 10.8), and stent C 22.5 N (17.1 to 27.9), p barbs added anchoring strength. During traction, the weaker barbs were distorted or caused intimal tears. The stronger barbs engaged the entire aortic wall. The radial force of the stents had no impact on fixation, while aortic calcification and graft oversizing had marginal effects. Stent barbs and hooks increased the fixation of stent-grafts tenfold, while the radial force of stents had no impact. These data may prove important in future endograft development to prevent stent-graft migration after aneurysm exclusion.

  5. Retroperitoneal aortic hemorrhage caused by penetration of an endovascular stent-graft anchoring barb.

    Science.gov (United States)

    Twine, Christopher P; Winterbottom, Andrew; Shaida, Nadeem; Boyle, Jonathan R

    2013-08-01

    To report a rare case of acute intraoperative retroperitoneal hemorrhage secondary to aortic penetration by the suprarenal anchoring barb on a stent-graft. A 75-year-old patient on dual antiplatelet therapy for coronary stents and low-molecular-weight heparin for atrial thrombus underwent elective endovascular repair of a 6.7-cm infrarenal abdominal aortic aneurysm. A device with suprarenal fixation and metal anchoring barbs was implanted, and a molding balloon was used that at no time covered the proximal bare metal stents or barbs. In recovery, the patient became tachycardic and hypotensive. After resuscitation, imaging identified an anterior barb penetrating the aortic wall, causing the acute retroperitoneal hemorrhage. A decision to treat conservatively rather than resort to open surgery was difficult but ultimately influenced by the patients' high risk for open surgery. The patient was treated by aggressive reversal of heparin and platelet transfusion, and the bleed settled spontaneously. Major surgery and subsequent morbidity may be avoided by medical management of what would appear to be a surgical problem.

  6. Endovascular Treatment of Ruptured Abdominal Aneurysm into the Inferior Vena Cava in Patient After Stent Graft Placement

    International Nuclear Information System (INIS)

    Juszkat, Robert; Pukacki, Fryderyk; Zarzecka, Anna; Kulesza, Jerzy; Majewski, Waclaw

    2009-01-01

    We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The procedure was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.

  7. Spinal ischaemia after thoracic endovascular aortic repair with left subclavian artery sacrifice: is there a critical stent graft length?

    Science.gov (United States)

    Kari, Fabian A; Saravi, Babak; Krause, Sonja; Puttfarcken, Luisa; Wittmann, Karin; Förster, Katharina; Rylski, Bartosz; Maier, Sven; Göbel, Ulrich; Siepe, Matthias; Czerny, Martin; Beyersdorf, Friedhelm

    2017-08-24

    Thoracic endovascular aortic repair (TEVAR) is used for treatment of thoracic aortic pathologies, but the covered stent graft can induce spinal ischaemia depending on the length used. The left subclavian artery contributes to spinal cord collateralization and is frequently occluded by the stent graft. Our objective was to investigate the impact of covered stent graft length on the risk of spinal ischaemia in the setting of left subclavian artery sacrifice. Twenty-six pigs (German country race, mean body weight 36 ± 4 kg) underwent simulated descending aortic TEVAR via left lateral thoracotomy, with left subclavian artery and thoracic segmental artery occlusion in normothermia. Animals were assigned to treatment groups according to simulated stent graft length: TEVAR to T8 ( n  = 4), TEVAR to T9 ( n  = 4), TEVAR to T10 ( n  = 4), TEVAR to T11 ( n  = 7) and TEVAR to T12 ( n  = 1) and a sham group ( n  = 6). End points included spinal cord perfusion pressure, cerebrospinal fluid pressure and spinal cord blood flow using fluorescent microspheres. There were no group differences in spinal cord perfusion pressure drop or in spinal cord perfusion pressure regeneration potential at 3 h after the procedure: from a baseline average of 75 mmHg (95% confidence interval 71-83 mmHg) to 73 mmHg (67-75 mmHg) at 3 h in Group T10 versus from a baseline average of 67 mmHg (95% CI 50-81 mmHg) to 65 mmHg (95% confidence interval 48-81 mmHg) in Group T8. There were no differences in the spinal cord blood flow courses over time in the different groups nor was there any difference in cerebrospinal fluid pressure levels and cerebrospinal fluid pressure dynamics between groups. However, we did observe local blood flow distribution to the spinal cord that was inhomogeneous depending on the distance between the simulated stent graft end and the first thoracic anterior radiculomedullary artery. The risk of spinal ischaemia after serial

  8. Acute Symptomatic Abdominal Aortic Aneurysm Secondary to Endovascular Stent Graft Associated Type II Endoleak

    Directory of Open Access Journals (Sweden)

    Karen Ka Leung Chan

    2006-07-01

    Full Text Available Endovascular abdominal aneurysm repair (EVAR is popular because of its low invasiveness and feasibility for high-risk patients. Endoleak is common after EVAR and is characterized by blood flow within the aneurysm sac but outside the stent graft. Type II or collateral endoleak commonly results from retrograde filling of the aneurysm from collateral visceral vessels, lumbar, inferior mesenteric, accessory renal or sacral arteries. Collateral leaks are generally thought to be benign and over half of the early leaks will seal spontaneously. Sporadically, collateral endoleak could lead to aneurysm sac pressurization and place the patient at ongoing risk of rupture. Herein, we report an uncommon case of early post-stent graft placement symptomatic abdominal aortic aneurysm associated with type II endoleak.

  9. Endovascular Treatment of Descending Thoracic Aortic Aneurysms with the EndoFit Stent-Graft

    International Nuclear Information System (INIS)

    Saratzis, N.; Saratzis, Athanasios; Melas, N.; Ginis, G.; Lioupis, A.; Lykopoulos, D.; Lazaridis, J.; Kiskinis, Dimitrios

    2007-01-01

    Objective. To evaluate the mid-term feasibility, efficacy, and durability of descending thoracic aortic aneurysm (DTAA) exclusion using the EndoFit device (LeMaitre Vascular). Methods. Twenty-three (23) men (mean age 66 years) with a DTAA were admitted to our department for endovascular repair (21 were ASA III+ and 2 refused open repair) from January 2003 to July 2005. Results. Complete aneurysm exclusion was feasible in all subjects (100% technical success). The median follow-up was 18 months (range 8-40 months). A single stent-graft was used in 6 cases. The deployment of a second stent-graft was required in the remaining 17 patients. All endografts were attached proximally, beyond the left subclavian artery, leaving the aortic arch branches intact. No procedure-related deaths have occurred. A distal type I endoleak was detected in 2 cases on the 1 month follow-up CT scan, and was repaired with reintervention and deployment of an extension graft. A nonfatal acute myocardial infarction occurred in 1 patient in the sixth postoperative month. Graft migration, graft infection, paraplegia, cerebral or distal embolization, renal impairment or any other major complications were not observed. Conclusion. The treatment of DTAAs using the EndoFit stent-graft is technically feasible. Mid-term results in this series are promising

  10. Emergency endovascular stent grafting for thoracic aortic pathology

    NARCIS (Netherlands)

    Bos, Wendy T. G. J.; Verhoeven, Eric L. G.; Zeebregts, Clark J. A. M.; Tielliu, Ignace F. J.; Prins, Ted R.; Oranen, Bjorn L.; van den Dungen, Jan J. A. M.

    2007-01-01

    Our aim was to report single-center results of emergency endovascular treatment for thoracic aortic disease. From March 1998 to January 2006, 30 acute thoracic EVAR procedures were carried out in 29 patients. One patient received two procedures in different settings. Four patients died before

  11. Open Versus Endovascular Stent Graft Repair of Abdominal Aortic Aneurysms

    DEFF Research Database (Denmark)

    Firwana, Belal; Ferwana, Mazen; Hasan, Rim

    2014-01-01

    We performed an analysis to assess the need for conducting additional randomized controlled trials (RCTs) comparing open and endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA). Trial sequential analysis (TSA) is a statistical methodology that can calculate the required inform...

  12. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    Thoracic endovascular aortic repair (TEVAR) has emerged as a promising therapeutic alternative to conventional open aortic replacement but it requires suitable proximal and distal landing zones for stent-graft anchoring. Many aortic pathologies affect in the immediate proximity of the left subcla...

  13. Endovascular repair of thoracoabdominal aortic aneurysms with a novel multibranch stent-graft design: preliminary experience.

    Science.gov (United States)

    Kinstner, C; Teufelsbauer, H; Neumayer, C; Domenig, C; Wressnegger, A; Wolf, F; Funovics, M

    2014-08-01

    The aim of this paper was to report our preliminary experience in outcome, safety and mid-term results in the treatment of thoracoabdominal aortic aneurysms (TAAA) with a novel multibranchstentgraft (E-xtra DESIGN ENGINEERING, JOTEC, Germany). Eight patients (mean age 66 years, 2 female) with TAAA (Crawford type I: 2 cases, type III: 3 cases, type IV: 3 cases), mean aneurysm diameter 61 mm, growth over 5 mm per year were treated. Implantation was performed under general anesthesia and surgical exposition of the common femoral artery. Brachial access was percutaneous in 5/8 patients. Balloon-expandable (Advanta V12) bridging stent-grafts were employed and lined with self-expanding nitinol stents. All patients except type IV TAAA received a spinal drainage catheter. The device was successfully deployed in 8/8 patients. 29/32 visceral branches were engaged. One stenosed celiac trunk was left untreated without further consequences, two renal arteries which could not be cannulated were revascularized with iliorenal bypass. One patient needed surgical revision of groin hematoma, one patient suffered from permanent protopathic sensory deficit. No renal complications occurred. Since the primary implantation was deliberately kept short and amount of contrast agent was minimised, four patients needed a secondary percutaneous procedure (Palmaz stent implantation for type I endoleak, re-PTA or additional bridging stent-graft implantation for type III endoleak). The assisted primary success rate was 8/8. Mean follow-up was 18 months. Success was stable in 7/8 patients, one patient shows type V endoleak with 5mm sac expansion. No mortality or complication occurred during follow-up. The JOTEC E-xtra DESIGN ENGINEERING multibranch stent-graft is a promising new candidate for endovascular TAAA treatment with sufficient safety and efficacy. Its short delivery time suggests its use in patients with rapid aneurysm growth or high anxiety.

  14. Pancreatitis-Associated Splenic Artery Pseudoaneurysm: Endovascular Treatment with Self-Expandable Stent-Grafts

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Vagenas, Kostantinos; Apostolopoulou, Sotiria C.; Panagiotou, Irene; Lymberopoulou, Dimitra; Kelekis, Dimitrios A.

    2003-01-01

    We present a patient with a splenic arterypseudoaneurysm (SAPA) treated with placement of self-expandable stent-grafts. The procedure was complicated by stent-graft migration,but successful management resulted in lasting exclusion of the SAPA,while the patency of the splenic artery was preserved. This is the first report of self-expandable stent-graft treatment of SAPA

  15. The impact of stent graft evolution on the results of endovascular abdominal aortic aneurysm repair.

    Science.gov (United States)

    Tadros, Rami O; Faries, Peter L; Ellozy, Sharif H; Lookstein, Robert A; Vouyouka, Ageliki G; Schrier, Rachel; Kim, Jamie; Marin, Michael L

    2014-06-01

    There have been four eras in the development of endovascular aneurysm repair (EVAR): physician-made grafts, early industry devices, intermediary commercial endografts, and modern stent grafts. This study analyzes differences in outcomes between these four groups and the impact of device evolution and increased physician experience. From 1992 to 2012, 1380 patients underwent elective EVAR. Fourteen different devices were used during this time. The four generations were defined as follows: era 1, all physician-made devices; era 2, June 1994 to June 2003; era 3, June 2003 to January 2008; and era 4, January 2008 to July 2012. Grafts used in each era were the following: era 1, physician made; era 2, early industry, such as EVT, Talent, AneuRx, Excluder, Quantum LP, Vanguard, Ancure, and Teramed; era 3, Talent, Endologix, Excluder, AAAdvantage, Zenith, and Aptus; and era 4, Zenith, Endurant, and Excluder. Mean age was 75.2 years, and 84.5% were men. Adjunctive procedures decreased from era 1 to era 2 (P < .001) but rose again in eras 3 and 4 (P < .001). Procedure times (P < .001), blood loss (P < .001), and length of stay (P < .001) have decreased in eras 2, 3, and 4 compared with era 1. Major perioperative complications (era 1, 23%; era 2, 5.9%; era 3, 4.9%; and era 4, 4.7%; P < .001), abdominal aortic aneurysm-related perioperative mortality (era 1, 4.3%; era 2, 0.2%; era 3, 0.06%; and era 4, 0.5%; P < .001), and all-cause perioperative mortality (era 1, 7.7%; era 2, 1.9%; era 3, 1.5%; and era 4, 0.47%; P < .001) have also decreased in eras 2, 3, and 4 compared with era 1. Type I and type III endoleaks (P < .001) and the need for reintervention (P < .001) have decreased. Freedom from aneurysm-related mortality has significantly improved. EVAR has evolved during the last 20 years, resulting in an improvement in efficiency, outcomes, and procedural success. The most significant advance is seen in the transition from era 1 to the later eras. Copyright © 2014 Society for

  16. Ten-Year Follow-Up of Endovascular Aneurysm Treatment with Talent Stent-Grafts

    International Nuclear Information System (INIS)

    Pitton, Michael B.; Scheschkowski, Tobias; Ring, Markus; Herber, Sascha; Oberholzer, Katja; Leicher-Dueber, Annegret; Neufang, Achim; Schmiedt, Walther; Dueber, Christoph

    2009-01-01

    The purpose of this study was to evaluate the clinical results, complications, and secondary interventions during long-term follow-up after endovascular aneurysm repair (EVAR) and to investigate the impact of endoleak sizes on aneurysm shrinkage. From 1997 to March 2007, 127 patients (12 female, 115 male; age, 73.0 ± 7.2 years) with abdominal aortic aneurysms were treated with Talent stent-grafts. Follow-up included clinical visits, contrast-enhanced MDCT, and radiographs at 3, 6, and 12 months and then annually. Results were analyzed with respect to clinical outcome, secondary interventions, endoleak rate and management, and change in aneurysm size. There was no need for primary conversion surgery. Thirty-day mortality was 1.6% (two myocardial infarctions). Procedure-related morbidity was 2.4% (paraplegia, partial infarction of one kidney, and inguinal bleeding requiring surgery). Mean follow-up was 47.7 ± 34.2 months (range, 0-123 months). Thirty-nine patients died during follow-up; three of the deaths were related to aneurysm (aneurysm rupture due to endoleak, n = 1; secondary surgical reintervention n = 2). During follow-up, a total of 29 secondary procedures were performed in 19 patients, including 14 percutaneous procedures (10 patients) and 15 surgical procedures (12 patients), including 4 cases with late conversion to open aortic repair (stent-graft infection, n = 1; migration, endoleak, or endotension, n = 3). Overall mean survival was 84.5 ± 4.7 months. Mean survival and freedom from any event was 66.7 ± 4.5 months. MRI depicted significantly more endoleaks compared to MDCT (23.5% vs. 14.3%; P 10% of the aneurysm area were associated with reduced aneurysm shrinkage compared to no endoleaks or <10% endoleaks (Δ at 3 years, -1.8% vs. -12.0%; P < 0.05). In conclusion, endovascular aneurysm treatment with Talent stent-grafts demonstrated encouraging long-term results with moderate secondary intervention rates. Primary occlusion of all aortic side

  17. Endovascular Treatment of Dialysis Access-Induced Hand Ischemia Using a Flared Stent-Graft.

    Science.gov (United States)

    Png, Chien Yi M; Beckerman, William E; Faries, Peter L; Finlay, David J

    2017-10-01

    To report an investigation of a purely endovascular procedure to address access-induced hand ischemia in dialysis patients. Two dialysis patients presented with stage III steal syndrome consisting of severe pain and numbness in their fingers. Preoperative fistulograms distal to the anastomosis showed alternating antegrade and retrograde flow. Under ultrasound guidance, the fistula was accessed and a 4-F micropuncture sheath placed. An angled guidewire was then advanced proximally into the brachial artery. A 6-F short sheath with marker was placed followed by a 4-F straight guide catheter inserted into the proximal brachial artery. A 9-F Flair endovascular stent-graft was advanced over a 0.035-inch stiff angled Glidewire into the fistula just distal to the arterial anastomosis and deployed. Postoperatively, pain and numbness resolved in both patients immediately. Postoperative fistulograms documented antegrade flow. Access flow velocity readings decreased significantly and pulse oximetry readings increased significantly in both patients, who were followed for >6 months with no reported complications. These 2 cases suggest that this endovascular approach to access-induced hand ischemia may be a viable alternative to open/hybrid surgery.

  18. Emergency treatment of acute rupture of the descending thoracic aorta using endovascular stent-grafts.

    Science.gov (United States)

    Amabile, Philippe; Rollet, Gilles; Vidal, Vincent; Collart, Frédéric; Bartoli, Jean-Michel; Piquet, Philippe

    2006-11-01

    Open surgical management of acute rupture of the descending thoracic aorta (DTA) is associated with high mortality and morbidity. Endovascular stent-grafts (ESGs) could provide a less invasive treatment alternative to conventional open surgery. The purpose of this report detailing our experience using ESG for treatment of acute rupture of the DTA is to determine the indications for endovascular repair. From June 2000 to April 2005, 17 patients presenting rupture of the DTA were treated using commercially available ESGs at our institution. There were two women and 15 men, with a mean age of 41.9 +/- 20.5 years. The cause of aortic rupture was traumatic in 13 cases and nontraumatic in four. Treatment was undertaken immediately in 10 cases and delayed in seven (range 5-68 days, mean 23.5). In one patient, the proximal neck landing zone was prepared prior to endovascular repair. No patients died during the postoperative period. The technical success rate was 84%. One patient developed a proximal type 1 endoleak at the end of the procedure. Three complications, i.e., two iliac dissections and one femoral artery rupture, occurred during the procedure. No paraplegia was observed. Mean follow-up was 13.3 months (range 1-41). One patient treated for traumatic rupture was lost from follow-up 21 months after initial treatment. No procedure-related complication was observed in this traumatic rupture group. Control computed tomographic scan at 13 months following the procedure demonstrated no evidence of periprosthetic leak or false aneurysm. In the nontraumatic rupture group, two patients died of aortic rupture and one treated for aortobronchial fistula developed recurrent hemoptysis 23 months after initial treatment and required placement of two additional ESGs. The immediate outcome of covered stent-graft placement for management of acute aortic rupture of the DTA is good. However, long-term surveillance is mandatory, especially in patients treated for nontraumatic aortic

  19. Endovascular Repair of Saccular Ascending Aortic Aneurysm After Orthotopic Heart Transplantation Using an Investigational Zenith Ascend Stent-Graft.

    Science.gov (United States)

    Oderich, Gustavo S; Pochettino, Alberto; Mendes, Bernardo C; Roeder, Blayne; Pulido, Juan; Gloviczki, Peter

    2015-08-01

    To report the use of an investigational stent-graft to treat an ascending aortic aneurysm in a patient with a heart transplant. A 48-year-old man presented with a 3.5×1.5-cm saccular aneurysm in the mid anterior ascending aorta, abutting the sternum. The patient's history was notable for placement of a left ventricular assist device followed by orthotopic heart transplantation 2 years prior to treat end-stage familial dilated cardiomyopathy. Under compassionate use, a custom-designed ascending aortic stent-graft (Zenith Ascend) was successfully delivered via an 18-F system and deployed just distal to the origin of the left main coronary artery under pulmonary artery catheter-guided rapid ventricular pacing. The patient was discharged the next day, and 6-month follow-up was unremarkable. Imaging at 5 months showed an excluded aneurysm sac with no endoleak or migration. The ideal ascending aortic stent-graft should be low profile, conformable to the arch anatomy, with short tip delivery system and a stepwise deployment mechanism that allows precise placement relative to the ostia of the coronary arteries and the innominate artery. This case illustrates the advancement of endovascular techniques to the most challenging segment of the aorta to decrease morbidity and mortality in high-risk patients. © The Author(s) 2015.

  20. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    subclavian artery (LSA) limiting the proximal landing zone site without proximal vessel coverage. In patients in whom the distance between the LSA and aortic lesion is too short, extension of the landing zone can be obtained by covering the LSA's origin with the endovascular stent graft (ESG). This manoeuvre...... and analysed three basic treatment concepts for LSA revascularisation in TEVAR patients (prophylactic, conditional prophylactic and no prophylactic LSA revascularisation). The available evidence supports prophylactic revascularisation of the LSA before ESG LSA coverage when preoperative imaging reveals...

  1. Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting

    Directory of Open Access Journals (Sweden)

    Youngok Lee

    2016-12-01

    Full Text Available The intrinsic structural failure of a Dacron graft resulting from the loss of structural integrity of the graft fabric can cause late graft complications. Late non-anastomotic rupture has traditionally been treated surgically via open thoracotomy. We report a case of the successful use of thoracic endovascular repair to treat a Dacron graft rupture in the descending aorta. The rupture occurred 20 years after the graft had been placed. Two stent grafts were placed at the proximal portion of the surgical graft, covering almost its entire length.

  2. Clinical application of 64 multi-slice CT angiography for the follow-up of endovascular stent-graft exclusion

    International Nuclear Information System (INIS)

    Yin Longlin; Chen Jiayuan; Jiang Jin; Yang Zhigang; Li Zhenlin; Sun Jiayu; Zhu Hongmei

    2009-01-01

    Objective: To investigate the clinical applications of 64-MSCTA for the follow-up of endovascular stent-graft exclusion (EVE). Methods: Between Oct 2006 and Feb 2008, forty-four 64-MSCTA examinations were performed in 30 patients with aortic dissection (AD) and 5 patients with abdominal aortic aneurysm (AAA) who underwent EVE. Imaging reconstruction including MPR, MIP and VR were finished on workstation. The outcomes and complications after EVE of aortic dissection and aortic aneurysm were evaluated. Results: (1) Of 30 patients with aortic dissection, large thrombosis in false lumen was observed in 28 cases and small thrombosis in 2 cases. The cavity of aortic aneurysm outside the stent was thrombosed completely in 5 patients with AAA. (2) Thrombosis in the innominate artery on follow-up CTA after EVE was found in 1 AD patient with the innominate artery involved, Thrombosis in the superior mesenteric artery was observed on 15 days follow-up CTA but thrombolysis on 3 months after EVE in 1 case, Intimal tear in right common iliac artery was found in 1 case. Of 5 patients with AAA, occlusion of right inner iliac artery was observed in 1 case, and instent thrombosis in distal right common iliac artery was found in 1 case. (3) Endoleak was found in 14 patients with AD, including 8 with type I and 6 with type III endoleaks, one type III endoleak was disappeared on follow-up CTA after 3 months. Conclusions: 64-MSCTA with fast, non-invasive and effective merits, combining multiple reconstructive methods, has become one of preferred imaging methods in post-operative evaluation of EVE. (authors)

  3. Endovascular Stent Graft Placement in the Treatment of Ruptured Tuberculous Pseudoaneurysm of the Descending Thoracic Aorta: Case Report and Review of the Literature

    International Nuclear Information System (INIS)

    Dogan, Sozen; Memis, Ahmet; Kale, Arzum; Buket, Suat

    2009-01-01

    We report a successful repair of a ruptured tuberculous pseudoaneurysm of the descending thoracic aorta by endovascular stent graft placement. This procedure is starting to be accepted as an alternative method to surgery, and we review similar cases in the literature.

  4. Spontaneous rupture of superficial femoral artery repaired with endovascular stent-grafting with use of rendez-vous technique, followed by delayed infection.

    Science.gov (United States)

    Fanelli, Fabrizio; Cannavale, Alessandro; Gazzetti, Marianna; Fantozzi, Cristiano; Taurino, Maurizio; Speziale, Francesco

    2013-02-01

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient's clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

  5. Endovascular Aortic Aneurysm Repair with the Talent Stent-Graft: Outcomes in Patients with Large Iliac Arteries

    International Nuclear Information System (INIS)

    England, Andrew; Butterfield, John S.; McCollum, Charles N.; Ashleigh, Raymond J.

    2008-01-01

    The purpose of this study is to report outcomes following endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) in patients with ectatic common iliac arteries (CIAs). Of 117 AAA patients treated by EVAR between 1998 and 2005, 87 (74%) had CIAs diameters 18 but <25 mm. All patients were treated with Talent stent-grafts, 114 bifurcated and 3 AUI devices. Departmental databases and patient records were reviewed to assess outcomes. Technical success, iliac-related outcome, and iliac-related reintervention (IRSI) were analyzed. Patients with EVAR extending into the external iliac artery were excluded. Median (range) follow-up for the study group was 24 (1-84) months. Initial technical success was 98% for CIAs <18 mm and 100% for CIAs ≥18 mm (p = 0.551). There were three distal type I endoleaks (two in the ectatic group) and six iliac limb occlusions (one in an ectatic patient); there were no statistically significant differences between groups (p = 0.4). There were nine IRSIs (three stent-graft extensions, six femorofemoral crossover grafts); three of these patients had one or both CIAs ≥18 mm (p = 0.232). One-year freedom from IRSI was 92% ± 3% and 84% ± 9% for the <18-mm and ≥18-mm CIA groups, respectively (p = 0.232). We conclude that the treatment of AAA by EVAR in patients with CIAs 18-24 mm appears to be safe and effective, however, it may be associated with more frequent reinterventions.

  6. Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones

    Directory of Open Access Journals (Sweden)

    Ying Guan

    2016-08-01

    Full Text Available Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU and polyester graft (nitinol-PET materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.

  7. Outcomes of Endovascular Aneurysm Repair using the Ovation Stent Graft System in Adverse Anatomy.

    Science.gov (United States)

    Greaves, Nicholas S; Moore, Aiden; Seriki, Dare; Ghosh, Jonathan

    2018-04-01

    The aim was the evaluation of mid-term efficacy and safety outcome measures for the Ovation (Endologix, Santa Rosa, CA, USA) stent graft system in the management of infrarenal abdominal aortic aneurysms (iAAA) with adverse anatomy. A retrospective observational study of all patients undergoing elective iAAA repair was carried out from 2012 to 2017 using Ovation Prime or iX stent grafts with a minimum of 3 months follow-up at a single UK vascular centre. Post-operative surveillance involved computed tomography scans at 3 months and 1 year, with duplex ultrasound yearly thereafter. Outcome measures were established with retrospective analysis of pre- and post-operative imaging, and included peri-operative mortality, major adverse events, limb complications, aneurysm diameter change, and endoleak rates. All patients were within Ovation instructions for use (IFU), and assessment was made to determine whether aneurysms had anatomical features considered adverse for other commonly used stent graft platforms. Ovation stent grafts were implanted in 52 patients (79% male, mean age 75.7 years) with a mean aneurysm diameter of 62.5 mm (range 55-107 mm). There was 100% technical deployment success. The 30 day mortality was 0% and there was no aneurysm related mortality during follow-up (median 24 months, range 3-48 months). There were no type I or III endoleaks, but 19% developed type II endoleaks with one patient requiring re-intervention. No iliac limb occlusions were identified but one case required relining for limb kinking. All 52 cases were within the IFU for Ovation but only 12% met the IFU criteria for the Cook and Medtronic devices. The mid-term experience with Ovation demonstrates safe, durable treatment of iAAAs, including those with unfavourable anatomy, frequently off IFU for other commonly used devices. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  8. Treatment of Stanford type B aortic dissection with stent-grafts: preliminary results.

    Science.gov (United States)

    Czermak, B V; Waldenberger, P; Fraedrich, G; Dessl, A H; Roberts, K E; Bale, R J; Perkmann, R; Jaschke, W R

    2000-11-01

    To evaluate the feasibility and safety of endovascular stent-graft placement in treating Stanford type B aortic dissection. Seven patients underwent endovascular stent-graft placement for type B aortic dissection. Five patients had acute and two had chronic dissection. In five patients, the proximal entry tear was within 2 cm of the origin of the left subclavian artery, and in two patients it was beyond this site. In three patients, the noncovered proximal portion of the stent-graft was placed across the origin of the left subclavian artery. The efficacy of the procedure was assessed at follow-up studies 3, 6, 12, and 24 months after intervention. The procedure was technically and clinically successful in six patients (86%). The left subclavian artery remained patent in all patients. In two patients with involvement of aortic branches, endovascular stent-graft placement restored adequate blood flow to the compromised branches. One patient was readmitted 1 month later because the dissection extended into the ascending aorta. In all but this patient, closure of the entry tear and thrombosis of the false lumen along the stent-graft were achieved. All false lumina shrank considerably. The mean follow-up time was 14 months (range, 1-25 months). Type B aortic dissections within and beyond 2 cm of the origin of the left subclavian artery can be treated safely and effectively by means of endovascular stent-graft placement.

  9. Fenestrated Stent-Grafts for Salvage of Prior Endovascular Abdominal Aortic Aneurysm Repair

    NARCIS (Netherlands)

    Katsargyris, A.; Yazar, O.; Oikonomou, K.; Bekkema, F.; Tielliu, I.; Verhoeven, E. L. G.

    Objectives: To review our experience with fenestrated endovascular aneurysm repair (F-EVAR) to treat complications after previous standard infrarenal endovascular aneurysm repair (EVAR). Methods: A prospectively maintained database including all consecutive patients with juxtarenal abdominal aortic

  10. Endovascular Treatment of a Giant Superior Mesenteric Artery Pseudoaneurysm Using a Nitinol Stent-Graft

    International Nuclear Information System (INIS)

    Gandini, Roberto; Pipitone, Vincenzo; Konda, Daniel; Pendenza, Gianluca; Spinelli, Alessio; Stefanini, Matteo; Simonetti, Giovanni

    2005-01-01

    A 68-year-old woman presenting with gastrointestinal bleeding (hematocrit 19.3%) and in a critical clinical condition (American Society of Anesthesiologists grade 4) from a giant superior mesenteric artery pseudoaneurysm (196.0 x 131.4 mm) underwent emergency endovascular treatment. The arterial tear supplying the pseudoaneurysm was excluded using a 5.0 mm diameter and 31 mm long monorail expanded polytetrafluoroethylene (ePTFE)-covered self-expanding nitinol stent. Within 6 days of the procedure, a gradual increase in hemoglobin levels and a prompt improvement in the clinical condition were observed. Multislice CT angiograms performed immediately, 5 days, 30 days and 3 months after the procedure confirmed the complete exclusion of the pseudoaneurysm

  11. Management of Endovascular Aortic Aneurysm Complications via Retrograde Catheterization Through the Distal Stent-Graft Landing Zone.

    Science.gov (United States)

    Zhang, Xicheng; Sun, Yuan; Chen, Zhaolei; Jing, Yuanhu; Xu, Miao

    2017-08-01

    A retrograde technique through the gap between the distal stent landing zone and the iliac artery wall has been applied to treat type II endoleak after endovascular aortic aneurysm repair (EVAR). In this study, we tried to investigate its efficacy in the management of type III endoleak and intraoperative accidental events. We reported 2 complications of EVAR that were difficult to treat with conventional methods. One patient had a sustained type III endoleak after EVAR, and the right renal artery was accidentally sealed by a graft stent in the other patient during the operation. Both complications were managed by the retrograde technique from the distal stent landing zone. In the first case, the endoleak was easily embolized by the retrograde catheterization technique, and in the second case, a stent was implanted in the right renal artery using the retrograde technique to restore blood flow. In some EVAR cases, the technique of retrograde catheterization through the distal stent-graft landing zone is feasible, safe, and easy to perform.

  12. Endovascular stent-graft exclusion of aortic dissection combined with renal failure

    International Nuclear Information System (INIS)

    Feng Xiang; Jing Zaiping; Yuan Weijie; Bao Junmin; Zhao Zhiqing; Zhao Jun; Lu Qingsheng

    2003-01-01

    Objective: To investigate the indications and peri-operative management of endovascular graft exclusion of aortic dissection combined with renal failure. Methods: Endovascular graft exclusion for Stanford B type thoracic aortic dissection had been preformed on 136 patients including two complicated with renal failure. Hemodialysis was preformed before operation with the fluid infusion controlled during the operation and bed-side hemodialysis after the operation for the latter. Results: All the 2 cases with renal failure complication were successfully carried out, and the peri-operative metabolism and circulation were kept on smoothly. Conclusions: Under good peri-operative management, patients having aortic dissection combined with renal failure could receive the endovascular graft exclusion of aortic dissection safely

  13. Retrograde type A dissection: a serious complication due to thoracic aortic endovascular stent-graft repair for Stanford type B aortic dissection

    International Nuclear Information System (INIS)

    Wang Guoquan; Zhai Shuiting; Li Tianxiao; Shi Shuaitao; Zhang Kewei; Li Kun

    2011-01-01

    Objective: to discuss the possible causes and prevention of retrograde type A dissection occurred after thoracic aortic endovascular stent-graft repair (TEVAR) for symptomatic type B dissection. Methods: During the period from January 2005 to January 2011, TEVAR was carried out in 189 patients (157 males and 32 females) with symptomatic type B dissection. The average age of the patients was (51.2±13.5) years, ranged from 26 to 78 years. A follow-up lasting for 3-63 months (mean 32 months) was conducted in 135 patients (71.43%). Fifty-four patients lost in touch with the authors (28.57%). The occurrence of retrograde type A dissection after TEVAR was calculated and the possible causes were analyzed. Results: After TEVAR retrograde type A dissection occurred in two patients (1.48%), and both were males. One patient developed retrograde type A dissection in perioperative period, and the patient refused to have surgery. Conservative treatment was employed for over three years and be was still alive so far. The other patient developed retrograde type A dissection one month after TEVAR, and emergency surgery was performed. The patient was followed up for three months and he was still alive. Conclusion: The retrograde type A dissection occurred after TEVAR may be closely related to the stent-graft device, to the interventional manipulations and to the vascular disorders. Close attention should be paid to the direct damage produced by the stent-graft device to the vascular wall. (authors)

  14. Endovascular “Intimal Flap Septostomy” for Safe Landing of a Stent Graft in an Anastomotic Pseudoaneurysm of Chronic Type B Aortic Dissection

    Directory of Open Access Journals (Sweden)

    Yoshiaki Saito

    Full Text Available : Objective/Background: The purpose of this report is to demonstrate a novel endovascular technique for gaining and producing the maximal landing zone for a thoracic stent graft in a patient with a chronic type B aortic dissection. Methods: The patient was a 64 year old man with chronic type B aortic dissection. He had developed acute type B aortic dissection and undergone descending thoracic replacement (Zone 2–Th10 12 years earlier. During follow-up, he developed an anastomotic false aneurysm distally. In the initial operation, the distal anastomosis was performed with fenestration of the dissecting membrane. Computed tomography showed a pseudoaneurysm of 54 mm that was positioned 9 cm proximal to the coeliac artery. The landing zone was < 20 mm in the fenestrated area. At surgery, the true and false lumens were each cannulated from the femoral artery, and a pull through form was made just above the fenestrated flap. After the wire exchange, a 4 mm cutting balloon was positioned on the bottom of the flap, and the flap was gently sawed about 3.5 cm. Results: After stent graft placement no endoleak was observed. The patient was discharged without any complications. Conclusion: This technique was effective in producing a sufficient landing zone for endovascular aortic repair in a patient with an anastomotic pseudoaneurysm of chronic type B aortic dissection. Keywords: TEVAR, Thoracic aortic aneurysm, Chronic type B aortic dissection, Endovascular fenestration

  15. Endovascular repair of posttraumatic multiple femoral-femoral and popliteal-popliteal arteriovenous fistula with Viabahn and excluder stent graft

    Directory of Open Access Journals (Sweden)

    Šarac Momir

    2011-01-01

    . Also, numerous metallic balls - grains of shotgun were present. After the preoperative preparation under local infiltrative anesthesia, transfemoral endovascular reconstruction was done of the surface femoral and popliteal artery by the use of stent grafts Viabahn 6 × 50 mm and excluder PXL 161 007. Within the immediate postoperative course a significant reduction of the leg edema and disappearance of thrill occurred, and, latter, healing of ulceration, and disappearance of signs of the foot ischemia. Also, patient's both cardiac and breathing functions became normal. Conclusion. In patients with chronic traumatic AV fistulas in the femoropopliteal region, especially with multiple fistulas, the gold standard is their endovascular reconstruction which, although being minimally traumatic and invasive, offers a complete reconstruction besides keeping integrity of both distal and proximal circulation in the leg.

  16. Third- versus Second-Generation Stent Graft for Endovascular Aneurysm Repair: A Device-Specific Analysis.

    Science.gov (United States)

    Bergonti, Marco; Teruzzi, Giovanni; Santagostino, Giulia; Grancini, Luca; Ferrari, Cristina; Trabattoni, Daniela; Lualdi, Alessandro; Bartorelli, Antonio

    2017-10-01

    Our purpose is to analyze the outcomes of endovascular aneurysm repair (EVAR) in patients treated with Excluder endograft (W.L. Gore and Associate, Flagstaff, AZ), comparing second generation, featuring SIM-PULL delivery system (ExSP) and third generation, featuring C3 (ExC3), concerning intraprocedural data and long-term outcomes. In our single-center, comparative study, we retrospectively analyzed all patients undergoing elective EVAR with Excluder from May 2008 to December 2015. This cohort was firstly divided according to the design of the endograft used, and then, two subgroups of complex procedures were identified according to International Standards. Preliminary end points were early- and mid-term outcomes. Primary end point was procedural data (i.e., procedural and fluoroscopy time, radiation dose (DAP), and contrast medium amount). The study included 64 patients (24 ExSP and 40 ExC3) with a mean follow-up of 31.6 ± 22.9 months. Patients in ExC3 group had significantly more risk factors (past or present history of smoking, P = 0.019), comorbidities (chronic heart failure and chronic kidney disease, both P = 0.032), as well as a more unfavorable anatomy (neck angulation, P = 0.035). Concerning preliminary outcome, no significant between-group difference was noted. As for intraoperative data, procedure duration was significantly shorter: 120 vs. 151 min (P = 0.002) in the overall population and 129 vs. 173 min (P = 0.004) in complex cases. A significant reduction was also found in fluoroscopy time and radiation exposure: 24,084 vs. 32,548 cGy/cm 2 (P = 0.020) in the overall population and 26,770 vs. 41,104 cGy/cm 2 (P = 0.003) in complex cases. No significant difference was found for contrast volume. The study shows that new C3 excluder enables to reduce radiation exposure and procedural time compared to the previous device. C3 excluder results are comparable to those of the previous device in spite of more comorbidities and complex anatomy

  17. Endovascular abdominal aortic repair for AAA. Anatomical suitability and limitation in Japanese population according to the inclusion criteria of Zenith AAA stent graft

    International Nuclear Information System (INIS)

    Kitagawa, Atsushi; Okita, Yutaka; Okada, Kenji

    2009-01-01

    Since 2007, the EVAR (endovascular abdominal aortic repair) grafts, Zenith, Excluder and Powerlink had been commercially available in Japan. However, a small iliac artery, typical of Japanese population especially in women, was a limiting factor to indicate EVAR. We analyzed the suitability of EVAR in Japanese population according to the inclusion criteria of Zenith AAA stent graft in the current study. From January 2006 to December 2007, 106 AAA (abdominal aortic aneurysm) patients (88 men, 18 women) with a mean age of 73 years were investigated in our institution by multi-slice CT scan in terms of suitability of EVAR, then we measured their abdominal aorta and iliac artery parameters as follows; proximal neck diameter (PND) and length (PNL), common iliac artery diameter (CIAD) and length (CIAL), suprarenal (SNA) and infrarenal neck angulation (INA), external iliac artery diameter (EIAD) and aortic length from the lowest renal artery to the aortic bifurcation (AOL). The inclusion criteria for Zenith AAA stent graft treatment were; PND: 18-28 mm, PNL more than 15 mm, unilateral CIAD less than 20 mm, CIAL at least 10 mm, SNA less than 45 degree and INA less than 60 degree, unilateral EIAD more than 7.5 mm. The indication of EVAR was 25.5% (27/106 patients), and was especially very low in women (5.6%) strictly according to the inclusion criteria of the Zenith AAA stent graft. The main reason of exclusion of EVAR was proximal short neck (40.5%), small iliac artery (30.4%) and infrarenal aortic neck angulation (29.1%). In our analysis, female AAA patients had small PNL and EIAD with angulated neck compared with male AAA ones. Anatomical suitability of EVAR in Japanese population strictly following by the inclusion criteria of Zenith AAA stent graft was low due to their characteristic differences from the European Union (EU) and the United States (US) patients, such as short proximal neck, steep neck angulation and small iliac artery, especially in women. More flexible

  18. Tratamento do aneurisma da aorta toracoabdominal com endoprótese ramificada para as artérias viscerais Branched endovascular stent graft for thoracoabdominal aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    André Simi

    2007-03-01

    AATA com endoprótese ramificada é factível. A melhora dos recursos técnicos e da qualidade dos materiais poderá ampliar a indicação desse procedimento como alternativa à cirurgia aberta.We report a case of branched stent graft system for endovascular repair of thoracoabdominal aortic aneurysm (TAAA. A 68-year-old female patient, smoker, hypertensive, with a large TAAA and multiple comorbid conditions that restricted indication for conventional surgery. The aneurysm originated from the descending thoracic aorta, extending until the infrarenal abdominal aorta, involving the emergence of visceral arteries, celiac trunk, superior and renal mesenteric arteries. The TAAA was treated with the endovascular technique using a branched stent graft. This stent graft was customized based on the anatomical characteristics of the aorta and on the position of visceral branches, which were obtained by tomographic angiography, with the aim of excluding the aneurysm and maintaining perfusion of visceral arteries. The procedure was performed under regional and general anesthesia in the surgical room, preceded by cerebrospinal fluid drainage under fluoroscopic guidance. The femoral arteries, which were previously dissected, were used to implement the branched stent graft and for radiological control. Through the stent graft branches, secondary extensions were implanted, with covered stents, to the respective visceral arteries, which were approached via left axillary artery. Total operative time was 14 hours, 4 hours and 30 minutes of fluoroscopy time and 120 mL of iodinated contrast. The patient became hemodynamically unstable after the surgery. Transesophageal echocardiogram showed a type A retrograde dissection of the thoracic aorta, followed by spontaneous thrombosis of the false lumen. Control tomography showed exclusion of the TAAA and patency of the bypasses to visceral branches, with no endoleaks. The patient was discharged on the 13th postoperative day. Branched

  19. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  20. Fluid-structure interaction of a patient-specific abdominal aortic aneurysm treated with an endovascular stent-graft.

    LENUS (Irish Health Repository)

    Molony, David S

    2009-01-01

    BACKGROUND: Abdominal aortic aneurysms (AAA) are local dilatations of the infrarenal aorta. If left untreated they may rupture and lead to death. One form of treatment is the minimally invasive insertion of a stent-graft into the aneurysm. Despite this effective treatment aneurysms may occasionally continue to expand and this may eventually result in post-operative rupture of the aneurysm. Fluid-structure interaction (FSI) is a particularly useful tool for investigating aneurysm biomechanics as both the wall stresses and fluid forces can be examined. METHODS: Pre-op, Post-op and Follow-up models were reconstructed from CT scans of a single patient and FSI simulations were performed on each model. The FSI approach involved coupling Abaqus and Fluent via a third-party software - MpCCI. Aneurysm wall stress and compliance were investigated as well as the drag force acting on the stent-graft. RESULTS: Aneurysm wall stress was reduced from 0.38 MPa before surgery to a value of 0.03 MPa after insertion of the stent-graft. Higher stresses were seen in the aneurysm neck and iliac legs post-operatively. The compliance of the aneurysm was also reduced post-operatively. The peak Post-op axial drag force was found to be 4.85 N. This increased to 6.37 N in the Follow-up model. CONCLUSION: In a patient-specific case peak aneurysm wall stress was reduced by 92%. Such a reduction in aneurysm wall stress may lead to shrinkage of the aneurysm over time. Hence, post-operative stress patterns may help in determining the likelihood of aneurysm shrinkage post EVAR. Post-operative remodelling of the aneurysm may lead to increased drag forces.

  1. Structural implications of fenestrated stent graft misalignment.

    Science.gov (United States)

    Crawford, S A; Itkina, M; Doyle, M G; Tse, L W; Amon, C H; Roche-Nagle, G

    2018-04-01

    Endovascular aneurysm repair is a minimally-invasive method for the treatment of abdominal aortic aneurysms. For aneurysms that involve the visceral arteries, a custom-made stent graft with fenestrations for the branch arteries is required. The purpose of the current study is to evaluate the structural impact of misaligned fenestrations with respect to luminal patency and proximal aortic neck apposition in an in vitro model. A custom apparatus was used to evaluate seven Anaconda and three Zenith fenestrated stent grafts. All stent grafts were evaluated at 10° increments of stent/fenestration misalignment up to 80°. Images were captured at each interval and the luminal cross-sectional area and wall apposition were measured. The Anaconda stent graft, which has an unsupported main body, demonstrated a linear reduction in luminal patency at increasing angles of misalignment (P < 0.0001). Stent/fenestration misalignments of 20° and 80° resulted in decreases in mean luminal patency of 14% and 54% respectively. The Zenith stent graft demonstrated a similar decrease in luminal patency, starting at misalignments of ≥40° (P < 0.0001). However, with stent/fenestration misalignments of ≥30°, apposition between the Zenith stent graft and the simulated aortic neck was compromised suggesting the creation of a type Ia endoleak. Both the Anaconda and Zenith devices behave adversely at extreme angles of misalignment with luminal narrowing in the Anaconda device and loss of wall apposition in the Zenith device; however, both stent grafts appear to be equivalent at low angles of misalignment. Copyright © 2016 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  2. Repeated transluminal endovascular Inoue stent graft placement for progressive dilatation of prosthetic graft that had been repaired with Inoue stent graft placement for dilatation 23 years after extraanatomical bypass.

    Science.gov (United States)

    Anzai, Tomohiro; Shimizu, Hideyuki; Yozu, Ryohei; Hashimoto, Subaru; Kuribayashi, Sachio; Inoue, Kanji

    2007-02-01

    A 76-year-old man had undergone aneurysm exclusion and ascending abdominal aortic extraanatomical bypass for a thoracoabdominal aortic aneurysm in 1978. In 1983 hemoptysis occurred, and resection and closure of the central stump of the aorta and a left lower lobectomy were performed. Dilatation (phi50 mm) of a prosthetic graft (Cooley Graft phi18 mm) used for extraanatomical bypass was noted in 2001 and was repaired by placement of an Inoue stent graft. However, the aneurysm diameter increased further (phi70 mm), although no endoleak was noted: Placement of an Inoue stent graft covering the whole length of the prosthetic graft was repeated in 2006. The postoperative course was smooth, no endoleak occurred, and the patient was discharged 2 weeks after surgery.

  3. Automatic segmentation of the wire frame of stent grafts from CT data.

    NARCIS (Netherlands)

    Klein, A.; Vliet, J.A. van der; Oostveen, L.J.; Hoogeveen, Y.L.; Schultze Kool, L.J.; Renema, W.K.J.; Slump, C.H.

    2012-01-01

    Endovascular aortic replacement (EVAR) is an established technique, which uses stent grafts to treat aortic aneurysms in patients at risk of aneurysm rupture. Late stent graft failure is a serious complication in endovascular repair of aortic aneurysms. Better understanding of the motion

  4. Shear accumulation as a means for evaluating risk of thromboembolic events in novel endovascular stent graft designs.

    Science.gov (United States)

    Suess, Taylor; Anderson, Joseph; Sherman, Andrea; Remund, Tyler; Pohlson, Kathryn; Mani, Gopinath; Gent, Stephen; Kelly, Patrick

    2017-06-01

    This study proposes to establish a simulation-based technique for evaluating shear accumulation in stent grafts and to use the technique to assess the performance of a novel branched stent graft system. Computational fluid dynamics models, with transient boundary conditions, particle injection, and rigid walls, simplifying assumptions were developed and used to evaluate the shear accumulation in various stent graft configurations with a healthy aorta as comparison. Shear streamlines are presented for the various configurations. Shear accumulation was also calculated for each configuration. The number of particles with shear accumulations >3.5 Pa-s for each configuration was compared with the shear accumulation values of commercially available mechanical aortic valves from the literature. The stent graft configuration with the diaphragm does have particles with shear accumulation >3.5 Pa-s. However, the percentage of particles with shear accumulation above 3.5 Pa-s is less than the two commercially available mechanical aortic valves, and more surprisingly, is smaller than in the healthy aorta. Copyright © 2016. Published by Elsevier Inc.

  5. Delayed Development of Brain Abscesses Following Stent-Graft Placement in a Head and Neck Cancer Patient Presenting with Carotid Blowout Syndrome

    International Nuclear Information System (INIS)

    Oweis, Yaseen; Gemmete, Joseph J.; Chaudhary, Neeraj; Pandey, Aditya; Ansari, Sameer

    2011-01-01

    We describe the delayed development of intracranial abscesses following emergent treatment with a covered stent-graft for carotid blowout syndrome (CBS) in a patient with head and neck cancer. The patient presented with hemoptysis and frank arterial bleeding through the tracheostomy site. A self-expandable stent-graft was deployed across a small pseudoaneurysm arising from the right common carotid artery (RCCA) and resulted in immediate hemostasis. Three months later, the patient suffered a recurrent hemorrhage. CT of the neck demonstrated periluminal fluid around the caudal aspect of the stent-graft with intraluminal thrombus and a small pseudoaneurysm. Subsequently, the patient underwent a balloon test occlusion study and endovascular sacrifice of the RCCA and right internal carotid artery. MRI of the brain demonstrated at least four ring-enhancing lesions within the right cerebral hemisphere consistent with intracranial abscesses that resolved with broad-spectrum antibiotic coverage.

  6. CT Imaging Findings and Their Relevance to the Clinical Outcomes After Stent Graft Repair of Penetrating Aortic Ulcers: Six-year, Single-center Experience

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ji Hoon [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology (Korea, Republic of); Angle, John F.; Park, Auh Whan; Anderson, Curtis; Sabri, Saher S.; Turba, Ulku C. [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States); Kern, John A.; Cherry, Kenneth J. [University of Virginia Health System, Department of Surgery (United States); Matsumoto, Alan H., E-mail: ahm4d@virginia.edu [University of Virginia Health System, Division of Angiography, Interventional Radiology and Special Procedures, Department of Radiology (United States)

    2012-12-15

    Purpose: To present the computed tomographic (CT) imaging findings and their relevance to clinical outcomes related to stent graft placement in patients with penetrating aortic ulcers (PAUs). Methods: Medical and imaging records and imaging studies were reviewed for consecutive patients who underwent stent graft repair of a PAU. The distribution and characteristics of the PAU, technical success of stent graft repair, procedure-related complications, associated aortic wall abnormalities, and outcomes of the PAUs at follow-up CT scans were evaluated. Results: Fifteen patients underwent endovascular treatment for PAU. A total of 87% of the PAUs were in the proximal (n = 8) or distal (n = 5) descending thoracic aorta. There was a broad spectrum of PAU depth (mean, 7.9 {+-} 5.6 mm; range 1.5-25.0 mm) and diameter (mean, 13.5 {+-} 9.7 mm; range 2.2-41.0 mm). Atherosclerosis of the thoracic aorta and intramural hematoma were associated in 53 and 93% of the patients, respectively. Technical success was achieved in 100%. Two or more stent grafts were used in five patients. Endoleaks were observed in two patients within 2 weeks of the procedure, both of which resolved spontaneously. At follow-up CT scanning, regression and thrombosis of the PAUs were observed in all patients. The average patient survival was 61.8 months, with an overall mortality of 13% (2 of 15) at follow-up. Neither death was related to the endograft device or the PAU. Conclusion: Endovascular stent graft placement was safe and effective in causing regression and thrombosis of PAUs in this small series of patients. Two or more stent grafts were used in five patients (33%) with associated long-segmental atherosclerotic changes of the thoracic aorta or intramural hematoma.

  7. Real-world performance of the new C3 Gore Excluder stent-graft: 1-year results from the European C3 module of the Global Registry for Endovascular Aortic Treatment (GREAT).

    Science.gov (United States)

    Verhoeven, E L G; Katsargyris, A; Bachoo, P; Larzon, T; Fisher, R; Ettles, D; Boyle, J R; Brunkwall, J; Böckler, D; Florek, H-J; Stella, A; Kasprzak, P; Verhagen, H; Riambau, V

    2014-08-01

    The European C3 module of the Global Registry for Endovascular Aortic Treatment (GREAT) provides "real-world" outcomes for the new C3 Gore Excluder stent-graft, and evaluates the new deployment mechanism. This report presents the 1-year results from 400 patients enrolled in this registry. Between August 2010 and December 2012, 400 patients (86.8% male, mean age 73.9 ± 7.8 years) from 13 European sites were enrolled in this registry. Patient demographics, treatment indication, case planning, operative details including repositioning and technical results, and clinical outcome were analyzed. Technical success was achieved in 396/400 (99%) patients. Two patients needed intraoperative open conversion, one for iliac rupture, the second because the stent-graft was pulled down during a cross-over catheterization in an angulated anatomy. Two patients required an unplanned chimney renal stent to treat partial coverage of the left renal artery because of upward displacement of the stent-graft. Graft repositioning occurred in 192/399 (48.1%) patients, most frequently for level readjustment with regard to the renal arteries, and less commonly for contralateral gate reorientation. Final intended position of the stent-graft below the renal arteries was achieved in 96.2% of patients. Thirty-day mortality was two (0.5%) patients. Early reintervention (≤30 days) was required in two (0.5%) patients. Mean follow-up duration was 15.9 ± 8.8 months (range 0-37 months). Late reintervention (>30 days) was required in 26 (6.5%) patients. Estimated freedom from reintervention at 1 year was 95.2% (95% CI 92.3-97%), and at 2 years 91.5% (95% CI 86.8-94.5%). Estimated patient survival at 1 year was 96% (95% CI 93.3-97.6%) and at 2 years 90.6% (95% CI 85.6-93.9%). Early real-world experience shows that the new C3 delivery system offers advantages in terms of device repositioning resulting in high deployment accuracy. Longer follow-up is required to confirm that this high deployment accuracy

  8. Research of Customized Aortic Stent Graft Manufacture

    Science.gov (United States)

    Zhang, Lei; Chen, Xin; Liu, Muhan

    2017-03-01

    Thoracic descending aorta diseases include aortic dissection and aortic aneurysm, of which the natural mortality rate is extremely high. At present, endovascular aneurysm repair (EVAR) has been widely used as an effective means for the treatment of descending aortic disease. Most of the existing coating stents are standard design, which are unable to meet the size or structure of different patients. As a result, failure of treatment would be caused by dimensional discrepancy between stent and vessels, which could lead to internal leakage or rupture of blood vessels. Therefore, based on rapid prototyping sacrificial core - coating forming (RPSC-CF), a customized aortic stent graft manufactured technique has been proposed in this study. The aortic stent graft consists of film and metallic stent, so polyether polyurethane (PU) and nickel-titanium (NiTi) shape memory alloy with good biocompatibility were chosen. To minimum film thickness without degrading performance, effect of different dip coating conditions on the thickness of film were studied. To make the NiTi alloy exhibit super-elasticity at body temperature (37°C), influence of different heat treatment conditions on austenite transformation temperature (Af) and mechanical properties were studied. The results show that the customized stent grafts could meet the demand of personalized therapy, and have good performance in blasting pressure and radial support force, laying the foundation for further animal experiment and clinical experiment.

  9. Thoracic Stent Graft Implantation for Aortic Coarctation with Patent Ductus Arteriosus via Retroperitoneal Iliac Approach in the Presence of Small Sized Femoral Artery

    Science.gov (United States)

    Korkmaz, Ozge; Beton, Osman; Goksel, Sabahattin; Kaya, Hakkı; Berkan, Ocal

    2016-01-01

    Endovascular stent graft implantation is a favorable method for complex aortic coarctation accompanied by patent ductus arteriosus. Herein, an 18-year-old woman with complex aortic coarctation and patent ductus arteriosus was successfully treated by endovascular thoracic stent graft via retroperitoneal approach. The reason for retroperitoneal iliac approach was small sized common femoral arteries which were not suitable for stent graft passage. This case is the first aortic coarctation plus patent ductus arteriosus case described in the literature which is treated by endovascular thoracic stent graft via retroperitoneal approach. PMID:27242935

  10. Automatic segmentation of the wire frame of stent grafts from CT data.

    Science.gov (United States)

    Klein, Almar; van der Vliet, J Adam; Oostveen, Luuk J; Hoogeveen, Yvonne; Kool, Leo J Schultze; Renema, W Klaas Jan; Slump, Cornelis H

    2012-01-01

    Endovascular aortic replacement (EVAR) is an established technique, which uses stent grafts to treat aortic aneurysms in patients at risk of aneurysm rupture. Late stent graft failure is a serious complication in endovascular repair of aortic aneurysms. Better understanding of the motion characteristics of stent grafts will be beneficial for designing future devices. In addition, analysis of stent graft movement in individual patients in vivo can be valuable for predicting stent graft failure in these patients. To be able to gather information on stent graft motion in a quick and robust fashion, we propose an automatic method to segment stent grafts from CT data, consisting of three steps: the detection of seed points, finding the connections between these points to produce a graph, and graph processing to obtain the final geometric model in the form of an undirected graph. Using annotated reference data, the method was optimized and its accuracy was evaluated. The experiments were performed using data containing the AneuRx and Zenith stent grafts. The algorithm is robust for noise and small variations in the used parameter values, does not require much memory according to modern standards, and is fast enough to be used in a clinical setting (65 and 30s for the two stent types, respectively). Further, it is shown that the resulting graphs have a 95% (AneuRx) and 92% (Zenith) correspondence with the annotated data. The geometric model produced by the algorithm allows incorporation of high level information and material properties. This enables us to study the in vivo motions and forces that act on the frame of the stent. We believe that such studies will provide new insights into the behavior of the stent graft in vivo, enables the detection and prediction of stent failure in individual patients, and can help in designing better stent grafts in the future. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Aortic coarctation associated with aortic valve stenosis and mitral regurgitation in an adult patient: a two-stage approach using a large-diameter stent graft.

    Science.gov (United States)

    Novosel, Luka; Perkov, Dražen; Dobrota, Savko; Ćorić, Vedran; Štern Padovan, Ranka

    2014-02-01

    We report a case of a staged surgical and endovascular management in a 62-year-old woman with aortic coarctation associated with aortic valve stenosis and mitral regurgitation. The patient was admitted for severe aortic valve stenosis and mitral valve incompetence. During hospitalization and preoperative imaging, a previously undiagnosed aortic coarctation was discovered. The patient underwent a 2-stage approach that combined a Bentall procedure and mitral valve replacement in the first stage, followed by correction of the aortic coarctation by percutaneous placement of an Advanta V12 large-diameter stent graft (Atrium, Mijdrecht, The Netherlands) which to our knowledge has not been used in an adult patient with this combination of additional cardiac comorbidities. A staged approach combining surgical treatment first and endovascular placement of an Advanta V12 stent graft in the second stage can be effective and safe in adult patients with coarctation of the aorta and additional cardiac comorbidities. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Endovascular Treatment of an Aortobronchial Fistula

    International Nuclear Information System (INIS)

    Numan, Fueruezan; Arbatli, Harun; Yagan, Naci; Demirsoy, Ergun; Soenmez, Binguer

    2004-01-01

    A 67-year-old man operated on 8 years previously for type B aortic dissection presented with two episodes of massive hemoptysis. An aortobronchial fistula was suspected with spiral computed tomography angiography, and showed a small pseudoaneurysm corresponding to the distal anastomotic site. The patient underwent endovascular stent-graft implantation and is asymptomatic 8 months after the procedure

  13. Clinical testing of Belarusian aortic stent graft system

    Directory of Open Access Journals (Sweden)

    А. П. Шкет

    2016-12-01

    Full Text Available Aim. The study looks at the results of clinical testing of the first Belarusian aortic stent graft system developed and manufactured by a team of specialists from RSPC "Cardiology", Minsk, Belarus, and Belarusian Technical University.Methods. The original system of aortic stent graft includes a delivery system and an aortic stent graft itself. It is used in surgical treatment of complicated and common aneurysms of the thoracic aorta, as well as in cases of concomitant thoracic aneurysms and heart pathology to be treated under cardiopulmonary bypass. Clinical testing of the stent graft was carried out according to the requirements of Ministry of Health of the Republic of Belarus on the basis of three different cardiac hospitals of the country. Results. All the three hospitals treated one patient each. The first patient underwent implantation of the stent graft into the descending thoracic aorta, with the thoracic aorta aneurysm isolated and the aortic valve replaced with bioprosthesis. The second patient underwent ascending aorta and aortic valve replacement with a conduit and implantation of aortic stent graft into the descending thoracic aorta. In the third patient the domestic aortic stent graft was implanted into the descending thoracic aorta with isolation of the thoracic aneurysm; aortic valve and ascending aorta were replaced with ‘MedEng' conduit and the aortic arch was also replaced, with the brachiocephalic arteries re-implanted in place. All the patients were followed-up for both early and long-term outcomes for more than 1 year and were examined by using CT angiography in the early postoperative period and after 1 year. Uncomplicated postoperative course was observed in all the patients. There were no complications in the long-term follow-up as well. CT angiography data confirmed good positioning of the stent graft and good isolation of the aneurysm lumen. Preoperative and postoperative СТ data of one patient are presented in the

  14. Retrograde ascending aortic dissection during or after thoracic aortic stent graft placement: insight from the European registry on endovascular aortic repair complications

    DEFF Research Database (Denmark)

    Eggebrecht, Holger; Thompson, Matt; Rousseau, Hervé

    2009-01-01

    BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic...

  15. 3D Stereoscopic Visualization of Fenestrated Stent Grafts

    International Nuclear Information System (INIS)

    Sun Zhonghua; Squelch, Andrew; Bartlett, Andrew; Cunningham, Kylie; Lawrence-Brown, Michael

    2009-01-01

    The purpose of this study was to present a technique of stereoscopic visualization in the evaluation of patients with abdominal aortic aneurysm treated with fenestrated stent grafts compared with conventional 2D visualizations. Two patients with abdominal aortic aneurysm undergoing fenestrated stent grafting were selected for inclusion in the study. Conventional 2D views including axial, multiplanar reformation, maximum-intensity projection, and volume rendering and 3D stereoscopic visualizations were assessed by two experienced reviewers independently with regard to the treatment outcomes of fenestrated repair. Interobserver agreement was assessed with Kendall's W statistic. Multiplanar reformation and maximum-intensity projection visualizations were scored the highest in the evaluation of parameters related to the fenestrated stent grafting, while 3D stereoscopic visualization was scored as valuable in the evaluation of appearance (any distortions) of the fenestrated stent. Volume rendering was found to play a limited role in the follow-up of fenestrated stent grafting. 3D stereoscopic visualization adds additional information that assists endovascular specialists to identify any distortions of the fenestrated stents when compared with 2D visualizations.

  16. Aortic Stent-Graft Infection Following Septic Complications of a Kidney Stone

    International Nuclear Information System (INIS)

    Berg, H. Rogier van den; Leijdekkers, Vanessa J.; Vahl, Anco

    2006-01-01

    A 73-year-old man was treated because of a renal pelvis blowout of the left kidney for which he received a nephrostomy catheter without antibiotic prophylaxis. Almost a year previously this patient had undergone endovascular repair of a symptomatic infrarenal abdominal aorta aneurysm. Four weeks after the diagnosis and treatment of the ruptured renal pelvis, a new computed tomography scan and ultrasound-guided fine needle aspiration confirmed the diagnosis of infected aortic stent-graft. An extra-anatomic axillo-uniiliac bypass and graft excision was performed. Two weeks after discharge the patient returned to the hospital with an occlusion of his left renal artery and died of renal failure. This is the first time an infected aortic stent-graft after a renal pelvis blowout has been reported. Although infections of aortic stent-grafts occur rarely, one should be aware of the possibility in aortic stent-graft patients undergoing abdominal procedures without antibiotic prophylaxis

  17. Validation of an image registration and segmentation method to measure stent graft motion on ECG-gated CT using a physical dynamic stent graft model

    NARCIS (Netherlands)

    Koenrades, Maaike A.; Struijs, Ella M.; Klein, Almar; Kuipers, Henny; Geelkerken, Robert H.; Slump, Cornelis H.

    2017-01-01

    The application of endovascular aortic aneurysm repair has expanded over the last decade. However, the long-term performance of stent grafts, in particular durable fixation and sealing to the aortic wall, remains the main concern of this treatment. The sealing and fixation are challenged at every

  18. Endovascular repair of para-anastomotic aortoiliac aneurysms.

    LENUS (Irish Health Repository)

    Tsang, Julian S

    2009-11-01

    The purpose of this study is to evaluate the use of endovascular stent grafts in the treatment of para-anastomotic aneurysms (PAAs) as an alternative to high-risk open surgical repair. We identified all patients with previous open aortic aneurysm repair who underwent infrarenal endovascular aneurysm repair (EVAR) at our institution from June 1998 to April 2007. Patient demographics, previous surgery, and operative complications were recorded. One hundred forty-eight patients underwent EVAR during the study period and 11 patients had previous aortic surgery. Of these 11 redo patients, the mean age was 62 years at initial surgery and 71 years at EVAR. All patients were male. Initial open repair was for rupture in five (45%) patients. The average time between initial and subsequent reintervention was 9 years. All patients were ASA Grade III or IV. Fifty-five percent of the PAAs involved the iliac arteries, 36% the abdominal aorta, and 9% were aortoiliac. Ten patients had endovascular stent-grafts inserted electively, and one patient presented with a contained leak. Aorto-uni-iliac stent-grafts were deployed in seven patients, and bifurcated stent-grafts in four patients. A 100% successful deployment rate was achieved. Perioperative mortality was not seen and one patient needed surgical reintervention to correct an endoleak. Endovascular repair of PAAs is safe and feasible. It is a suitable alternative and has probably now become the treatment of choice in the management of PAAs.

  19. The Bolton Treovance abdominal stent-graft: European clinical trial design.

    Science.gov (United States)

    Chiesa, R; Riambau, V; Coppi, G; Zipfel, B; Llagostera, S; Marone, E M; Kahlberg, A

    2012-10-01

    Endovascular aortic repair (EVAR) has emerged as a promising, less invasive alternative to conventional open surgery for the treatment of infrarenal abdominal aortic aneurysms (AAAs). In the last 20 years, the application rate of EVAR and its clinical results have significantly improved thanks to the evolution of stent-grafts and endovascular delivery systems. However, further development is still needed to reduce the incidence of complications and secondary re-interventions. The Treovance abdominal aortic stent-graft (Bolton Medical, Barcelona, Spain) is a new-generation endovascular device, developed to increase flexibility, lower profile, improve deployment and sealing mechanisms. In particular, it is provided with some innovative features as a double layer of proximal barbs (suprarenal and infrarenal) for supplemental fixation, dull barbs between modules to avoid potential leg disconnections, detachable outer sheath provided with a new-design hemostatic valve, and a double improved mechanism (slow motion and "pin and pull") for precise stent-graft deployment. A European prospective, non-randomized, multi-institutional, "first-in-human" trial (the ADVANCE trial) was conducted from March to December 2011 to assess the safety and performance of the Treovance stent-graft system before commercialization. Thirty patients with anatomically suitable non-ruptured AAAs were enrolled at five clinical sites in Italy, Spain, and Germany. EVAR was completed successfully in all patients. The stent-graft was delivered and deployed safely even in heavily angulated or calcified anatomies. No 30-day device-related complications nor deaths were observed. Preliminary experience with the Treovance abdominal stent-graft within the ADVANCE trial was satisfactory with regard to technical success and perioperative clinical results. Follow-up data are needed to assess mid- and long-term clinical outcomes, along with durability of this new-generation endovascular device.

  20. Treatment of a ruptured thoracoabdominal aneurysm with a stent-graft covering the celiac axis

    NARCIS (Netherlands)

    Jorna, Francisca H.; Verhoeven, Eric L. G.; Bos, Wendy T. J. G.; Prins, Ted R.; Dol, Johan A.; Reijnen, Michel M. P. J.

    2006-01-01

    Purpose: To present a case of successful emergency endovascular repair of a ruptured, probably mycotic, thoracoabdominal aortic aneurysm (TAAA) with a stent-graft deliberately covering the celiac axis. Case Report. A 79-year-old woman with significant pulmonary comorbidity presented with a ruptured

  1. Segmentation and motion estimation of stent grafts in abdominal aortic aneurysms

    NARCIS (Netherlands)

    Klein, Almar

    2011-01-01

    Patients with an Abdominal Aortic Aneurysm have a high risk of dying due to the rupture of a dilated aorta. Endovascular aneurysm repair is a technique to threat AAA, by which a stent graft prosthesis is implanted in the aorta of the patient. Due to its minimal invasive character, this intervention

  2. Mid-term Outcomes of Endovascular Repair of Ruptured Thoraco-abdominal Aortic Aneurysms with Off the Shelf Branched Stent Grafts.

    Science.gov (United States)

    Hongku, Kiattisak; Sonesson, Björn; Björses, Katarina; Holst, Jan; Resch, Timothy; Dias, Nuno V

    2018-03-01

    To assess the mid-term outcomes and feasibility of branched endovascular repair (b-EVAR) of ruptured thoracoabdominal aortic aneurysms (rTAAAs). All patients undergoing b-EVAR of rTAAAs between 2011 and 2016 were included. Pre-, intra and postoperative imaging was reviewed to assess technical success, outcomes, and feasibility of b-EVAR in the emergent setting. Eleven emergency b-EVAR of rTAAAs (10 aneurysms and 1 chronic dissection) were performed using off-the-shelf (OTS) branched stentgrafts. Only 18% of patients complied to the anatomical instruction-for-use of the OTS device; a small aortic lumen and occluded target vessels were the main violations. Median operative time was 430 (IQR 395-629) minutes. Technical failure was 36% including one intraoperative death, one target vessel catheterization failure, one type Ia and one type III endoleak. Thirty-day mortality was 27%. Only early re-intervention was for the type Ia endoleak. Spinal cord ischemia occurred in 4 patients (30%), of which 2 recovered completely. Median clinical follow-up were 15 (IQR 7-39) months respectively. The median clinical follow-up index (FUI) was 0.65 (0.32-0.95). Overall survival was 75 ± 21.7% at 18 months. Four branch occlusions occurred; one renal stent occlusion led to permanent hemodialysis. Branch patency was 87.5 ± 8.3% and 72.2 ± 12% at 1 and 2 years, respectively. One stentgraft migrated but no late major endoleak occurred. Emergency b-EVAR of rTAAA with OTS device is feasible despite a low anatomical suitability. With proper adjunctive procedures, it can be offered to most hemodynamically stable patients. These time-consuming complex procedures are not suitable for unstable patients. Often the procedure is done as life-saving in the emergency setting and reinterventions may be needed later. Consequently, the success rates are lower than in the elective setting. These results need to be confirmed by larger studies and longer follow-up. Copyright © 2017 European

  3. Durability of the Viabahn stent graft after axillary artery pseudoaneurysm exclusion

    Directory of Open Access Journals (Sweden)

    Aaron Y. Chen, BS

    2017-06-01

    Full Text Available Pseudoaneurysm formation caused by iatrogenic arterial injury during a regional anesthetic block is a rare complication. We report a case of a 56-year-old male patient who developed an axillary artery pseudoaneurysm caused by brachial plexus block performed for an upper extremity dialysis access operation. Successful repair of this pseudoaneurysm was achieved with endovascular stent graft exclusion. The repaired axillary artery with the stent graft remained patent after 10 years of follow-up. The successful long-term patency of this treatment and a strategy to potentially avoid this complication are discussed.

  4. Tissue Responses to Stent Grafts with Endo-Exo-Skeleton for Saccular Abdominal Aortic Aneurysms in a Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Il Young; Chung, Jin Wook; Kim, Hyo Cheol [Dept. of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul (Korea, Republic of); Choi, Young Ho; So Young Ho [Dept. of Radiology, Seoul National University Boramae Hospital, Seoul (Korea, Republic of); Kim, Hyun Beom [Dept. of Radiology, National Cancer Center, Goyang (Korea, Republic of); Min, Seung Kee [Dept. of Surgery, Seoul National University College of Medicine, Seoul (Korea, Republic of); Park, Jae Hyung [Dept. of Radiology, Gachon University Gil Medical Center, Incheon (Korea, Republic of)

    2014-10-15

    We evaluated the effect of close contact between the stent and the graft on the induction of endothelial covering on the stent graft placed over an aneurysm. Saccular abdominal aortic aneurysms were made with Dacron patch in eight dogs. The stent graft consisted of an inner stent, a expanded polytetrafluoroethylene graft, and an outer stent. After sacrificing the animals, the aortas with an embedded stent graft were excised. The aortas were inspected grossly and evaluated microscopically. The animals were sacrificed at two (n = 3), six (n = 3), and eight months (n = 2) after endovascular repair. In two dogs, the aortic lumen was occluded at two months after the placement. On gross inspection of specimens from the other six dogs with a patent aortic lumen, stent grafts placed over the normal aortic wall were covered by glossy white neointima, whereas, stent grafts placed over the aneurysmal aortic wall were covered by brownish neointima. On microscopic inspection, stent grafts placed over the normal aortic wall were covered by thin neointima (0.27 ± 0.05 mm, mean ± standard deviation) with an endothelial layer, and stent grafts placed over the aneurysmal aortic wall were covered by thick neointima (0.62 ± 0.17 mm) without any endothelial lining. Transgraft cell migration at the normal aortic wall was more active than that at the aneurysmal aortic wall. Close contact between the stent and the graft, which was achieved with stent grafts with endo-exo-skeleton, could not enhance endothelial covering on the stent graft placed over the aneurysms.

  5. Stent grafting of acute hepatic artery bleeding following pancreatic head resection

    International Nuclear Information System (INIS)

    Stoupis, Christoforos; Ludwig, Karin; Triller, Juergen; Inderbitzin, Daniel; Do, Dai-Do

    2007-01-01

    The purpose of this study was to report the potential of hepatic artery stent grafting in cases of acute hemorrhage of the gastroduodenal artery stump following pancreatic head resection. Five consecutive male patients were treated because of acute, life-threatening massive bleeding. Instead of re-operation, emergency angiography, with the potential of endovascular treatment, was performed. Because of bleeding from the hepatic artery, a stent graft (with the over-the-wire or monorail technique) was implanted to control the hemmorhage by preserving patency of the artery. The outcome was evaluated. In all cases, the hepatic artery stent grafting was successfully performed, and the bleeding was immediately stopped. Clinically, immediately after the procedure, there was an obvious improvement in the general patient condition. There were no immediate procedure-related complications. Completion angiography (n=5) demonstrated control of the hemorrhage and patency of the hepatic artery and the stent graft. Although all patients recovered hemodynamically, three individuals died 2 to 10 days after the procedure. The remaining two patients survived, without the need for re-operation. Transluminal stent graft placement in the hepatic artery is a safe and technically feasible solution to control life-threatening bleeding of the gastroduodenal artery stump. (orig.)

  6. Stent-graft treatment of a common carotid artery pseudoaneurysm.

    Science.gov (United States)

    Simionato, F; Righi, C; Melissano, G; Rolli, A; Chiesa, R; Scotti, G

    2000-04-01

    To report a case demonstrating successful endovascular treatment of a right common carotid artery pseudoaneurysm using a commercially prepared balloon-expandable covered stent. A 50-year-old man was evaluated for syncopal episodes. He had a history of severe trauma sustained in a motor vehicle accident 3 years before symptom onset. Doppler ultrasound scanning detected a pseudoaneurysm at the origin of the right common carotid artery. The defect measured 25 mm x 20 mm with a 22-mm-long neck on angiography and computed tomography; there was no evidence of carotid stenosis or associated vascular pathology. Via a percutaneous femoral access, 2 Jostent peripheral stent-grafts were placed at the level of the aneurysm, safely achieving complete repair of the arterial wall defect. The patient was asymptomatic at his 12-month evaluation. Color flow duplex scans showed continued exclusion of the pseudoaneurysm. Wide-necked aneurysms in the extracranial carotid arteries may be treated with stent-grafts, which can achieve complete and permanent reconstruction of the arterial wall by excluding the aneurysm.

  7. Electromagnetic Navigation for Thoracic Aortic Stent Graft Deployment: A Pilot Study in Swine

    Science.gov (United States)

    Abi-Jaoudeh, Nadine; Glossop, Neil; Dake, Michael; Pritchard, William F.; Chiesa, Alberto; Dreher, Matthew R.; Tang, Thomas; Karanian, John W.; Wood, Bradford J.

    2010-01-01

    Purpose The goal of this study was to determine the feasibility of electromagnetic tracking as a method to augment conventional imaging guidance for the safe delivery, precise positioning, and accurate deployment of thoracic aortic endografts. Materials & Methods Custom guidewires were fabricated and the delivery catheters for thoracic aortic endoprostheses (Gore TAG endoprostheses, W.L. Gore & Assoc. Inc., Flagstaff AZ) were retrofitted with integrated electromagnetic coil sensors enabling realtime endovascular tracking. Pre-procedure thoracic CTA were obtained after placement of fiducial skin patches on the chest wall of three anesthetized swine, enabling automatic registration. The stent graft deployment location target near the subclavian artery was selected on the pre-procedure CTA. Two steps were analyzed: advancing a tracked glidewire to the aortic arch, and positioning the tracked stent graft assembly using electromagnetic guidance alone. Multiple CT scans were performed to evaluate the accuracy of the electromagnetic tracking system by measuring the target registration error which compared the actual position of the tracked devices to the displayed “virtual” electromagnetic-tracked position. Post-deployment CTA and necropsy confirmed stent graft position and subclavian artery patency. Results A stent graft was successfully delivered and deployed in each of the three animals using real-time electromagnetic tracking alone. The mean of the fiducial registration error of the auto-registration was 1.5 mm. Sixteen comparative scans were obtained to determine the target registration error, which was 4.3mm ± 0.97 mm (Range: 3.0 to 6.0mm) for the glidewire sensor coil. The target registration error for the stent graft delivery catheter sensor coil was 2.6 mm ± 0.7 mm (Range: 1.9 to 3.8 mm). The deployment error for the stent graft defined as deployment deviation from target was 2.6mm ± 3.0 mm. Conclusion Delivery and deployment of customized thoracic stent

  8. Analysis of Iliac Artery Geometric Properties in Fenestrated Aortic Stent Graft Rotation.

    Science.gov (United States)

    Doyle, Matthew G; Crawford, Sean A; Osman, Elrasheed; Eisenberg, Naomi; Tse, Leonard W; Amon, Cristina H; Forbes, Thomas L

    2018-04-01

    A complication of fenestrated endovascular aneurysm repair is the potential for stent graft rotation during deployment causing fenestration misalignment and branch artery occlusion. The objective of this study is to demonstrate that this rotation is caused by a buildup of rotational energy as the device is delivered through the iliac arteries and to quantify iliac artery geometric properties associated with device rotation. A retrospective clinical study was undertaken in which iliac artery geometric properties were assessed from preoperative imaging for 42 cases divided into 2 groups: 27 in the nonrotation group and 15 in the rotation group. Preoperative computed tomography scans were segmented, and the iliac artery centerlines were determined. Iliac artery tortuosity, curvature, torsion, and diameter were calculated from the centerline and the segmented vessel geometry. The total iliac artery net torsion was found to be higher in the rotation group compared to the nonrotation group (23.5 ± 14.7 vs 14.6 ± 12.8 mm -1 ; P = .05). No statistically significant differences were found for the mean values of tortuosity, curvature, torsion, or diameter between the 2 groups. Stent graft rotation occurred in 36% of the cases considered in this study. Cases with high iliac artery total net torsion were found to be more likely to have stent graft rotation upon deployment. This retrospective study provides a framework for prospectively studying the influence of iliac artery geometric properties on fenestrated stent graft rotation.

  9. Treatment of pseudoaneurysms with stent-graft: preliminary experience in 12 cases

    International Nuclear Information System (INIS)

    Liao Denghui; Ye Caisheng; Li Songqi; Ye Runyi; Chang Guangqi; Chen Wei; Li Xiaoxi; Wang Shenming

    2012-01-01

    Objective: To asses the clinical effect of stent-graft in the treatment of pseudoaneurysms. Methods: During the period from March 2008 to June 2011, 86 patients with pseudoaneurysms were admitted to the hospital, of whom stent-graft implantation was carried out in 12. The pseudoaneurysms were located at the thoracic aorta (n=4), abdominal aorta (n=3), common carotid artery (n=3), internal carotid artery (n=1) and right subclavian artery (n=1). All the patient were followed up for 5-43 months. The clinical results were analyzed. Results: The technical success rate for stent delivery was 100%. The pseudoaneurysms was immediately isolated after the procedure in all 12 cases. After endovascular exclusion with stent-graft, no leakage occurred and the blood flow distal to the parent artery was normal. All patients were followed up for a mean period of 23.5 months except one who lost in touch with the authors. One patient with coexisting Behcet's disease died of massive bleeding due to abdominal aortic rupture four months after operation. The other patients were in good clinical condition, and no complications such as stent stenosis, displacement, internal leakage etc. were observed in the follow-up period. Conclusion: The implantation of stent-graft has satisfactory short-term effect in treating pseudoaneurysms, although its long-term efficacy needs to be further observed. (authors)

  10. Entire stent grafting of the thoracoabdominal aorta in a renal transplant recipient subsequent to extra-anatomical bypasses of the main abdominal vessels.

    Science.gov (United States)

    Kokotsakis, John; Kaskarelis, Ioannis; Koukoulaki, Maria; Athanasiou, Thanos; Skouteli, Elian; Vougas, Vassilios; Lioulias, Achilleas; Drakopoulos, Spiros

    2009-02-01

    We present a complex case of a renal transplant recipient with ruptured suprarenal abdominal aortic aneurysm who had previously undergone endovascular repair of descending thoracic and abdominal aortic aneurysm. This patient was treated successfully combining extra-anatomical bypasses of main abdominal arteries and subsequent endovascular stent grafting covering the entire thoracoabdominal aorta.

  11. Assessment of Competence in EVAR Stent Graft Sizing and Selection

    DEFF Research Database (Denmark)

    Strøm, M; Lönn, L.; Bech, B.

    2017-01-01

    Objectives and background: The aims of this study were to develop a test of competence in endovascular aortic repair (EVAR) stent graft sizing and selection; to examine the test for evidence of validity; and to explore the experience required for the task. Methods: The test was developed based...... on a literature review resulting in 22 anatomical assessment points and a graft selection. Validity evidence was explored in an international cross sectional study. Twenty-two consultants with varying levels of experience in the field (novices, intermediates, and experts) were presented with computed tomography...... angiography of the aortic vessels from three patients. Test scores were based on summed z-scores using the anatomical measurements and graft choices of the experts as a reference. A proficiency score was established using the contrasting groups standard setting method. Results: The assessment was shown...

  12. Importance of stent-graft design for aortic arch aneurysm repair

    Directory of Open Access Journals (Sweden)

    C Singh

    2017-02-01

    Full Text Available Aneurysm of the aorta is currently treated by open surgical repair or endovascular repair. However, when the aneurysm occurs in regions between the aortic arch and proximal descending aorta, it can be a complex pathology to treat due to its intricate geometry. When complex aortic aneurysms are treated with the conventional procedures, some of the patients present with significant post-operative complications and high mortality rate. Consequently, a clinically driven hybrid innovation known as the frozen elephant trunk procedure was introduced to treat complex aortic aneurysms. Although this procedure significantly reduces mortality rate and operating time, it is still associated with complications such as endoleaks, spinal cord ischemia, renal failure and stroke. Some of these complications are consequences of a mismatch in the biomechanical behaviour of the stent-graft device and the aorta. Research on complex aneurysm repair tended to focus more on the surgical procedure than the stent-graft design. Current stent-graft devices are suitable for straight vessels. However, when used to treat aortic aneurysm with complex geometry, these devices are ineffective in restoring the normal biological and biomechanical function of the aorta. A stent-graft device with mechanical properties that are comparable with the aorta and aortic arch could possibly lead to fewer post-operative complications, thus, better outcome for patients with complex aneurysm conditions. This review highlights the influence stent-graft design has on the biomechanical properties of the aorta which in turn can contribute to complications of complex aneurysm repair. Design attributes critical for minimising postoperative biomechanical mismatch are also discussed.

  13. Endovascular versus open repair for blunt thoracic aortic injury: short-term results.

    Science.gov (United States)

    Kokotsakis, John; Kaskarelis, Ioannis; Misthos, Panagiotis; Athanasiou, Thanos; Kanakakis, Konstantinos; Athanasiou, Chariklia; Romana, Constantina; Skouteli, Elian; Lioulias, Achilles

    2007-12-01

    Endovascular stent grafting has been increasingly used as an alternative treatment modality. The aim of this study is to evaluate the immediate and short-term results of endovascular stent grafting repair after blunt thoracic aortic injury due to trauma. A review of a tertiary trauma center registry identified all patients who suffered blunt thoracic aortic injury from 2002 to 2006. All patients underwent either open repair with synthetic graft interposition or endovascular stent grafting (EVS) of the descending thoracic aorta. Type and severity of injury, concomitant injuries, clinical factors, and outcome were compared between groups. Univariate and multivariate analysis was performed. Endovascular stent grafting was performed in 22 patients, and 10 patients underwent open surgical repair. In the open group, the 30-day mortality rate was 10%, the paraplegia rate was 10%, and incidence of major complications was 30%, which were comparable with the incidences observed in the EVS group of 4.5%, 4.5%, and 13.6%, respectively. No statistically significant differences were demonstrated. Multivariate regression analysis identified associated thoracic injury as the main independent predictor of hospital length of stay (p = 0.03, 95% confidence interval: 0.53 to 18.85). In the EVS group, 1 patient died in the short-term follow-up period and 2 cases of endovascular leak required additional treatment. Although postoperative mortality and morbidity between open and endovascular repair were comparable, EVS can be considered a safe alternative treatment modality in the therapeutic algorithm of blunt thoracic aortic injury particularly for the higher risk multitrauma patients.

  14. A novel measurement technique for the design of fenestrated stent grafts: Comparison with three-dimensional aorta models.

    Science.gov (United States)

    You, Ji Hoon; Kang, Sung-Gwon; Kim, Bong Man

    2013-01-01

    Stent graft placement is an acceptable treatment option for aortic disease, particularly for abdominal aortic aneurysm. At present, the use of stent grafts is expanding beyond current indications for use. Fenestrated stent grafts are used in patients with abdominal aortic aneurysms whose aortic anatomy is unsuitable for repair using standard devices. The success of fenestrated stent graft placement is largely dependent on planning, including obtaining measurements and designing the stent. To demonstrate a measurement technique that may be used for the design of fenestrated stent grafts to repair endovascular aneurysms, and to compare these measurements, obtained using archived two-dimensional patient data, with measurements obtained using a three-dimensional (3-D) computer-assisted design model. Fenestrated stent grafts were designed and fabricated based on computed tomographic angiography images. 3-D models were constructed using modelling software and rapid prototyping technology incorporated with fused deposition modelling. The stent grafts were trunk-type, with four holes for the visceral branches (celiac axis, superior mesenteric artery, right renal artery and left renal artery). Computed tomography scans of 10 patients with abdominal aortic aneurysms were reviewed. Axial, multiplanar reconstruction and curved multiplanar reconstruction images were used to measure 11 parameters. Sizing of the fenestrated aortic stent grafts was performed independently by an experienced interventional radiologist, and the results were compared with the same measurements calculated using the 3-D aorta model (generated using Materialise Interactive Medical Image Control System software [Materialise NV, Belgium]). Data were reported as the mean of the measurements. Measurements were evaluated using Bland-Altman analysis and concordance correlation coefficients (CCCs). A total of 10 fenestrated stent grafts were fabricated. The proximal landing section above the celiac axis (one

  15. Aneurysm growth after late conversion of thoracic endovascular aortic repair

    Directory of Open Access Journals (Sweden)

    Hirofumi Kasahara

    2015-01-01

    Full Text Available A 69-year-old man underwent thoracic endovascular aortic repair of a descending aortic aneurysm. Three years later, he developed impending rupture due to aneurysmal expansion that included the proximal landing zone. Urgent open surgery was performed via lateral thoracotomy, and a Dacron graft was sewn to the previous stent graft distally with Teflon felt reinforcement. Postoperatively, four sequential computed tomography scans demonstrated that the aneurysm was additionally increasing in size probably due to continuous hematoma production, suggesting a possibility of endoleaks. This case demonstrates the importance of careful radiologic surveillance after endovascular repair, and also after partial open conversion.

  16. Rational imaging concepts in the follow-up of stent-graft placements for aortic aneurysm and aortic dissection

    International Nuclear Information System (INIS)

    Hansmann, H.J.; Kampschulte, A.; Schumacher, H.; Noeldge, G.; Richter, G.M.

    2001-01-01

    Goal. To identify essential and relevant diagnostic algorithms in the follow-up of stent-grafts placed for aortic dissections and aneurysms based on our 7 years experience including the use of more than 10 different devices. Material and Methods. Evaluation of conventional biplane imaging, angiography, sonography, CT and MR in the efficacy of demonstrating endoleaks, sac shrinkage, changes of stent-graft integrity and, with special reference to MR-compatibility of various stent-graft devices. Results. Endoleaks are found in 20-30% of patients after endovascular exclusion of abdominal aortic aneurysms. However, this rate neither necessarily reflects the clinical course nor the onset and course of sac shrinkage. Physical long-term integrity of the devices is seen best on conventional bi-plane radiographs. Sonography is helpful only in selected patients (non-obese, good compliance) otherwise not providing information precisely enough for sac control. As gold standard both CT (CTA) and MR (MRA) are equally effective in the follow-up of endovascular stent-grafts, allowing 3D control of sac geometry in aneurysmal disease or hemodynamic changes in stent-grafts for aortic dissection. MRI is considered to be more effective in the detection of small endoleaks. Angiography is inferior to CT and MRI in the diagnosis of endoleaks and thus is required only for intervention planning in patients with suspected endoleaks. Two of 8 evaluated stent-graft devices proved to be prohibitive for MRI because of their severe artifacts productions (Life-path, Zenith) as a result of their thick metallic meshwork. Conclusion. CT including CTA with 2D and 3D reformatting is the method of choice for the follow up of stent-graft treatment of aortic disease. Depending on availability, MRI may be used alternatively. In young patients and for those with contraindications to iodinated contrast media MRI is a perfectly equivalent alternative. Especially in patients with known contraindications to

  17. Comparison of midterm results for the Talent and Endurant stent graft.

    Science.gov (United States)

    't Mannetje, Yannick W; Cuypers, Philippe W M; Saleem, Ben R; Bode, Aron S; Teijink, Joep A W; van Sambeek, Marc R H M

    2017-09-01

    Stent graft evolution is often addressed as a cause for improved outcomes of endovascular aneurysm repair for patients with an abdominal aortic aneurysm. In this study, we directly compared the midterm result of Endurant stent graft with its predecessor, the Talent stent graft (both Medtronic, Santa Rosa, Calif). Patient treated from January 2005 to December 2010 in a single tertiary center in The Netherlands with a Talent or Endurant stent graft were eligible for inclusion. Ruptured abdominal aortic aneurysms or patients with previous aortic surgery were excluded. The primary end point was the Kaplan-Meier estimated freedom from secondary interventions. Secondary end points were perioperative outcomes and indications for secondary interventions. In total, 221 patients were included (131 Endurant and 90 Talent). At baseline, the median aortic bifurcation was narrower for the Endurant (30 mm vs 39 mm; P Talent and Endurant, respectively. The estimated freedom from secondary interventions at 30 days, 1 year, 5 years, and 7 years was 94.3%, 89.4%, 72.2%, and 64.1% for Talent and 96.8%, 89.3%, 75.2%, and 69.2% for Endurant (P = .528). The indication for secondary interventions does differ; more patients required an intervention for a proximal neck-related complication (type Ia endoleak or migration) in the Talent group (18.2% vs 4.8%; P = .001), whereas more interventions for iliac limb stenosis were seen in the Endurant group (0.0% vs 4.8%; P = .044). In a binomial regression analysis, suprarenal angulation, infrarenal neck length, and type of stent graft were independent predictors of neck-related complications. Evolution from the Talent stent graft into the Endurant has resulted in significant reduction of infrarenal neck-related complications; on the other hand, iliac interventions increased. The overall midterm secondary intervention rate was comparable. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  18. [Evaluation of Radiation Dose during Stent-graft Treatment Using a Hybrid Operating Room System].

    Science.gov (United States)

    Haga, Yoshihiro; Chida, Kouichi; Kaga, Yuji; Saitou, Kazuhisa; Arai, Takeshi; Suzuki, Shinichi; Iwaya, Yoshimi; Kumasaka, Eriko; Kataoka, Nozomi; Satou, Naoto; Abe, Mitsuya

    2015-12-01

    In recent years, aortic aneurysm treatment with stent graft grafting in the X-ray fluoroscopy is increasing. This is an endovascular therapy, because it is a treatment which includes the risk of radiation damage, having to deal with radiation damage, to know in advance is important. In this study, in order to grasp the trend of exposure stent graft implantation in a hybrid operating room (OR) system, focusing on clinical data (entrance skin dose and fluoroscopy time), was to count the total. In TEVAR and EVAR, fluoroscopy time became 13.40 ± 7.27 minutes, 23.67 ± 11.76 minutes, ESD became 0.87 ± 0.41 mGy, 1.11 ± 0.57 mGy. (fluoroscopy time of EVAR was 2.0 times than TEVAR. DAP of EVAR was 1.2 times than TEVAR.) When using the device, adapted lesions and usage are different. This means that care changes in exposure-related factors. In this study, exposure trends of the stent graft implantation was able to grasp. It can be a helpful way to reduce/optimize the radiation dose in a hybrid OR system.

  19. [A re-operative case of bentall operation and aortic arch replacement using a stent graft for a Marfan syndrome, post sternum turnover and post mitral valve replacement].

    Science.gov (United States)

    Sasaki, H; Aomi, S; Noji, S; Uwabe, K; Kihara, S; Kurihara, H; Koyanagi, H

    2001-09-01

    A 36-year-old male with Marfan syndrome succesfully underwent Bentall operation and aortic arch replacement using a stent graft as an elephant trunk. He had received MVR with sternum turn over 14 years previously. Median sternotomy was performed. Under circulatory arrest with rertograde cerebral perfusion we performed Bentall operation and aortic arch replacement using a stent graft. The sternum was cured well. Retractive breathing was not detected. This surgical procedure was effective for cardiovascular disease with Marfan syndrome.

  20. Unusual rapid evolution of type B aortic dissection in a marfan patient following heart transplantation: successful endovascular treatment.

    Science.gov (United States)

    Botta, L; Russo, V; Grigioni, F; Arpesella, G; Rocchi, G; Di Bartolomeo, R; Fattori, R

    2006-10-01

    A patient with Marfan syndrome with previous Bentall operation for mitral and tricuspid valve repair, required orthotopic cardiac transplantation for end stage cardiomyopathy. Postoperatively he suffered type-B aortic dissection, despite normal aortic diameters. Following sudden increase of aortic diameters, two years later, he underwent successful stent graft implantation. In patients with Marfan syndrome, post transplantation morbidity is high, with a 40% incidence of thoracic aortic dissection. This case highlights the potential of endovascular approach for treating post-transplantation aortic dissection.

  1. Transaortic gunshot wound through perivisceral segment successfully managed by placement of thoracic stent graft

    Directory of Open Access Journals (Sweden)

    Jared T. Feyko, DO

    2018-03-01

    Full Text Available We describe a 36-year-old woman who presented to our facility after sustaining a gunshot wound to the epigastric region. The gunshot resulted in injury to the left lobe of the liver and the twelfth thoracic vertebral body as well as in a through-and-through injury to the abdominal aorta at the level of the celiac axis. The vascular injury was managed successfully by placement of a thoracic stent graft with coverage of the celiac axis. This case demonstrates the feasibility of managing this uncommon injury with endovascular techniques.

  2. Evaluation of CT virtual intravascular endoscopy in fenestrated stent grafts: a preliminary study

    International Nuclear Information System (INIS)

    Sun, Z.; Allen, Y.; Fitzsimmons, B.; Hartely, D.; Lawrence-Brown, M.

    2007-01-01

    We aim in this study to investigate the potential value of CT virtual intravascular endoscopy in patients diagnosed with abdominal aortic aneurysms undergoing fenestrated stent grafts. Both pre-and post-fenestration (within 3 months of implantation) multislice CT data were collected in eight patients and used for generation of virtual endoscopy images in our preliminary study. Variable fenestrations were deployed in 25 aortic branches with scallop fenestration implanted in six aortic ostia, large fenestration in four aortic ostia and small fenestration in 15 renal ostia, respectively. Measurements of the aortic ostia diameters both pre- and post-fenestration were successfully performed with virtual intravascular endoscopy visualization, and endovascular stents as well as their relationship to the aortic ostia were clearly demonstrated. Our results showed that there was no significant change of diameter of the aortic ostia following fenestrated stem grafts. Endovascular stents were clearly visualized on virtual endoscopy images, and no apparent deformity or malrotation was observed in this small group. Our preliminary study provides new insights into anatomic configuration/dimension of aortic ostia and endovascular stents, and virtual intravascular endoscopy could be a valuable technique to follow-up patients treated with fenestrated stent grafts. (orig.)

  3. Magnetizable stent-grafts enable endothelial cell capture

    Energy Technology Data Exchange (ETDEWEB)

    Tefft, Brandon J. [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Uthamaraj, Susheil [Division of Engineering, Mayo Clinic, Rochester, MN (United States); Harburn, J. Jonathan [School of Medicine, Pharmacy and Health, Durham University, Stockton-on-Tees (United Kingdom); Hlinomaz, Ota [Department of Cardioangiology, St. Anne' s University Hospital, Brno (Czech Republic); Lerman, Amir [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Dragomir-Daescu, Dan [Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN (United States); Sandhu, Gurpreet S., E-mail: sandhu.gurpreet@mayo.edu [Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States)

    2017-04-01

    Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance. - Highlights: • Magnetic stent-grafts were made from 2205 steel stents and polyurethane nanofibers. • Stent-grafts remained patent and formed a thin and uniform neointima when implanted. • Stent-grafts captured endothelial cells labeled with magnetic nanoparticles.

  4. Adolescent External Iliac Artery Trauma: Recurrent Aneurysmal Dilatation of an Iliofemoral Saphenous Vein Graft Treated by Stent-Grafting

    International Nuclear Information System (INIS)

    Lenton, James; Davies, John; Homer-Vanniasinkam, S.; McPherson, Simon

    2008-01-01

    An adolescent male sustained a severe penetrating injury to the external iliac artery. Emergency surgical revascularization was with a reversed long saphenous vein interposition graft. The primary graft and the subsequent revision graft both became aneurysmal. The second graft aneurysm was successfully excluded by endovascular stent-grafts with medium-term primary patency. A venous graft was used initially rather than a synthetic graft to reduce the risk of infection and the potential problems from future growth. Aneurysmal dilatation of venous grafts in children and adolescents is a rare but recognized complication. To the best of our knowledge, exclusion of these aneurysms with stent-grafts has not been previously reported in the adolescent population.

  5. Stent graft treatment for infra-inguinal arterial disease for either instent-restenosis and denovo lesions associated with very high rates of failure.

    Science.gov (United States)

    Golla, Maheswara S; Acharji, Subasit; Paul, Timir K; Madapathi, Praveena; Garcia, Lawrence A

    2017-12-07

    FDA approved the Gore Viabahn (WL Gore, Flagstaff, AZ, USA) stent for both femoro-popliteal arterial denovo and instent restenosis (ISRS) lesions. To date there is little data on Viabahn stent graft outcomes in ISRS arterial disease. Between 2007 and 2014 we identified 734 patients who underwent 1573 endovascular interventions in our institution for infra-inguinal revascularization. Among these, 48 patients had 143 Viabahn stents placed. Of these, 26 patients had 94 stents placed for ISRS and 22 patients had 49 stents placed for denovo lesions. The patients in the ISRS group were younger and more likely to have hypertension, hyperlipidemia, coronary artery disease, compared to the patients in the denovo group. Stents were placed principally for femoro-popliteal lesions, with mean length of 21 ± 12.5 cm (19.2 ± 14, ISRS vs. 22.1 ± 11, denovo; P = 0.2). Both groups had low primary patency rates during one year follow up (54% vs. 33%, OR = 2.3 (0.9-2.2). Target lesion revascularization (TLR) (57% vs. 27%, P ISRS group than in the denovo group. Amputation rate (17% vs. 31%, OR 0.7, CI = 0.2-1), cumulative blockage (defined as ISRS and thrombosis) (62% vs. 47%, P = 0.09, OR = 1.8, CI = 0.9-3.6), and Restenosis (40% vs. 31%, OR 1.5, CI = 0.7-3.2) were not statistically different between the two groups. Mean duration of follow-up was 12.8 ± 13 months. Stent graft treatment using the Gore Viabahn for denovo and ISRS in femoro-popliteal arterial obstructive disease have high restenosis and failure rates, of both stent patency and limb outcomes, which is consistent with existed literature. © 2017 Wiley Periodicals, Inc.

  6. Systemic inflammation, coagulopathy, and acute renal insufficiency following endovascular thoracoabdominal aortic aneurysm repair.

    Science.gov (United States)

    Chang, Catherine K; Chuter, Timothy A M; Niemann, Claus U; Shlipak, Michael G; Cohen, Mitchell J; Reilly, Linda M; Hiramoto, Jade S

    2009-05-01

    To characterize the inflammatory and coagulopathic response after endovascular thoracoabdominal aortic aneurysm (TAAA) repair and to evaluate the effect of the response on postoperative renal function. From July 2005 to June 2008, 42 patients underwent elective endovascular repair of a TAAA using custom designed multi-branched stent-grafts at a single academic institution. Four patients were excluded from the analysis. White blood cell count (WBC), platelet count, prothrombin time (PT), and creatinine were measured in all patients. In the last nine patients, interleukin-6 (IL-6), protein C, Factor V, d-dimers, cystatin C, and neutrophil gelatinase-associated lipocalin (NGAL) levels were also measured. Change in lab values were expressed as a percentage of baseline values. The 30-day mortality rate was 5% (2/38). All patients (n = 38) had a higher WBC (mean +/- SD: 139 +/- 80%, P acute renal insufficiency (>50% rise in creatinine). Patients with renal insufficiency had significantly larger changes in WBC (178 +/- 100% vs 121 +/- 64%, P = .04) and platelet count (64 +/- 17% vs 52 +/- 12%, P = .02) compared with those without renal insufficiency. All patients (n = 9) had significant increases in NGAL (182 +/- 115%, P = .008) after stent-graft insertion. Six of nine patients (67%) had increased cystatin C (35 +/- 43%, P = .04) after stent-graft insertion, with a greater rise in those with postoperative renal insufficiency (87 +/- 32% vs 8 +/- 13%, P = .02). IL-6 levels were markedly increased in all patients (n = 9) after repair (9840 +/- 6160%, P = .008). Protein C (35 +/- 10%, P = .008) and Factor V levels (28 +/- 20%, P = .008) were uniformly decreased, while d-dimers were elevated after repair in all patients (310 +/- 213%, P = .008). Leukocytosis and thrombocytopenia were uniform following endovascular TAAA repair, and the severity of the response correlated with post-operative renal dysfunction. Elevation of a sensitive marker of renal injury (NGAL) suggests that

  7. Experimental evaluation of complete endovascular arch reconstruction by in situ retrograde fenestration.

    Science.gov (United States)

    Canaud, Ludovic; Faure, Elsa Madeleine; Branchereau, Pascal; Ozdemir, Baris Ata; Marty-Ané, Charles; Alric, Pierre

    2014-12-01

    The aim of this experimental study was to assess the feasibility of complete endovascular arch reconstruction by in situ retrograde fenestration and to investigate the impact of stent-graft material on stent-graft fenestrations. The experiments were performed using 8 cadaveric human thoracic aortas (aortic arch) using 2 different stent-graft types: woven polyester (Valiant Captivia; Medtronic Vascular, Santa Rosa, CA) and expanded polytetrafluoroethylene (conformable [C]-TAG; W.L. Gore & Associates, Flagstaff, AZ). A benchtop aortic pulsatile flow model was used. Stent-grafts were deployed into the aortic arch, covering the ostia of the supraaortic trunks. A 5-mm 30-degree angioscope was introduced into the ascending aorta to monitor the procedure. Retrograde fenestration and deployment of the balloon expandable stent-graft was performed sequentially for each supraaortic trunk. Subsequent to stent-graft explantation, macroscopic evaluation of each fenestration was performed. All attempts to fenestrate the C-TAG and Valiant stent-grafts and implant the covered stent through the supraaortic trunks were successful. In all cases, branch stents were patent and no endoleak was evident. The Valiant stent-graft was easier to puncture because of the higher radial force of the stent-graft providing better counterpressure; however, stent-graft material had no impact on the quality of fenestrations. Total endovascular repair of the aortic arch through in situ retrograde fenestration of stent-grafts is feasible. The behavior of the 2 types of stent-graft was significantly different while the fenestrations were fashioned, but stent-graft material had no impact on the quality of fenestrations. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Endovascular treatment for arterial injuries of skull base

    International Nuclear Information System (INIS)

    Li Tianxiao; Bai Weixing; Zai Suiting; Wang Ziliang; Xue Jiangyu

    2008-01-01

    Objective: To explore the role of endovascular techniques in treatment for arterial injuries of skull base. Methods: A total of 53 consecutive cases suffered from skull base arterial injuries were enrolled in our hospital from Oct 2004 to May 2007, including 44 male and 9 female cases with average age of 23.3 years. Thirty-nine cases presented with pulsatile exophthalmos and intracranial vascular murmur, cerchnus and dysphagia in another 9, epistaxis in the remaining 5 cases. Diagnosis of 39 carotid cavernous fistulae (CCF)and 14 carotid pseudoaneurysm were performed by angiography (DSA). Alternative endovascular procedures were performed depending on lesions characteristics and follow-up was done by telephone and outpatient work up. Results: Procedures were performed involving 56 carotid arteries in all 53 cases including 34 CCF with embolization of detachable balloon(33 cases), 3 with balloon and coils, and 3 by stent-graft placement. 8 carotid pseudoaneurysms were cured by parent artery occlusion with balloon, 2 experienced endovascular isolation with balloon and coils, and 4 with stent-graft. Follow-up for mean 9.5 months (range from 2 to 25 months) revealed that the chief symptoms of 45 cases (85%) were relieved within 6 months after the procedure but ocular movement and visual disorder remained in 8 cases (15%)till 12 months. Six pseudoaneurysms and 3 residual leak were found in reexamination, of which 2 cases underwent intervention again 2 and 3 months later due to dural arterial-venous fistula in cavernous sinus, respectively. Conclusions: Endovascular treatment is safe and effective therapeutic option with minimal invasion for skull base arterial injuries. Detachable balloon embolization is the first choice for CCF and carotid pseudoaneurysm. Spring coil packing and stent-graft implantation should be in alternation as combination for special cases. (authors)

  9. Penetrating Atherosclerotic Ulcer of the Abdominal Aorta Involving the Celiac Trunk Origin and Superior Mesenteric Artery Occlusion: Endovascular Treatment

    International Nuclear Information System (INIS)

    Ferro, Carlo; Rossi, Umberto G.; Petrocelli, Francesco; Seitun, Sara; Robaldo, Alessandro; Mazzei, Raffaele

    2011-01-01

    We describe a case of endovascular treatment in a 64-year-old woman affected by a penetrating atherosclerotic ulcer (PAU) of the abdominal aorta with a 26-mm pseudoaneurysm involving the celiac trunk (CT) origin and with superior mesenteric artery (SMA) occlusion in the first 30 mm. The patient underwent stenting to treat the SMA occlusion and subsequent deployment of a custom-designed fenestrated endovascular stent-graft to treat the PAU involving the CT origin. Follow-up at 6 months after device placement demonstrated no complications, and there was complete thrombosis of the PAU and patency of the two branch vessels.

  10. Endovascular Therapy in Trauma

    Science.gov (United States)

    2014-11-23

    These can be complicated by thrombosis , embolism, and acute arterial insufficiency. Injuries involving the adventitia lead to pseudoaneurysm formation...common carotid, mesenteric , and iliac) and extremity vessel injury can also be accomplished endovascular stent-graft tech- niques (Fig. 1). As

  11. Endovascular management of the juxtarenal aortic aneurysm: can uncovered stents safely cross the renal arteries?

    Science.gov (United States)

    Malina, M; Brunkwall, J; Lindblad, B; Resch, T; Ivancev, K

    1999-09-01

    A short or otherwise suboptimal neck precludes the use of endovascular repair in 30% to 50% of patients with abdominal aortic aneurysms. Stent-graft fixation in an unsuitable neck carries the risk of technical failure owing to development of a proximal endoleak or stent-graft migration. Furthermore, in some patients, the neck dilates postoperatively. Endovascular healing with tissue incorporation into the graft material seems in and of itself insufficient to fixate the stent-graft adequately or to prevent neck dilation. Therefore, neck dilation is often associated with detachment of the stent-graft from the aortic wall, which is followed by the development of a proximal endoleak or stent-graft migration. Fixation of stent-grafts can be improved by placing the proximal stent above one or both of the renal artery orifices. Current experimental and clinical data suggest that renal function is not impaired by suprarenal aortic stents during the first year; however, this finding may not apply to all types of stents. Fixation of stent-grafts also may be improved by using stents with barbs that pierce the aortic wall. Additionally, the force that is exerted on the anchoring device may well be reduced by fully stented grafts with an associated increase in column strength. In the future, the risk of neck dilation and stent-graft dislodgement might also be limited by novel techniques such as laparoscopic banding of the neck or endoluminal stapling devices.

  12. Roentgen stereophotogrammetric analysis to study dynamics and migration of stent grafts

    NARCIS (Netherlands)

    Koning, Olivier Henk Jan

    2009-01-01

    The technique of RSA to determine stent-graft migration and FRSA to study stent-graft dynamics are explained in further detail in CHAPTER 2. CHAPTER 3 and 4 concern the accuracy and feasibility of RSA to detect stent-graft migration in a static model and in a model with pulsatile motion. The results

  13. Immediate endovascular stent-graft repair of an acute traumatic ...

    African Journals Online (AJOL)

    Enrique

    Acute rupture of the thoracic aorta after blunt injury carries a high initial mortality: up to 90% of patients die at the scene of the accident or before they reach the hospital.1-4. Traditional protocols have advocated emergency surgery for survivors reaching hospital, but this is accompanied by high operative mortality rates.

  14. Parallel Grafts Used in Combination with Physician-Modified Fenestrated Stent Grafts for Complex Aortic Aneurysms in High-risk Patients with Hostile Anatomies.

    Science.gov (United States)

    Touma, Joseph; Verscheure, Dorian; Majewski, Marek; Desgranges, Pascal; Cochennec, Frederic

    2018-01-01

    The objective of the study was to evaluate the feasibility and early outcomes of complex aortic aneurysm repair in high-risk patients with hostile anatomies using both parallel stents and physician-modified stent graft (PMSG) techniques to address the renovisceral arteries. Consecutive patients with complex suprarenal (SRA) and thoracoabdominal aortic aneurysms (TAAAs) undergoing endovascular repair using combined parallel stents technique and PMSG between September 2013 and November 2015 were evaluated. All patients required prompt aneurysm treatment. Fenestrations to preserve branch vessels were created in thoracic stent grafts. Depending on the anatomy, chimney or snorkel stents were deployed in renal or visceral arteries as complementary technique to overcome severe angulations or preexisting suprarenal stent. Preoperative, intraoperative, and postoperative data were recorded by means of a prospectively maintained database. Six high-risk patients with TAAA (type I: n = 2, type III: n = 1) and SRA (n = 3) underwent endovascular repair using both parallel stents technique and PMSG. Indications were painful aneurysms (n = 1) and >70-mm rapidly enlarging aneurysms (n = 5). Ten thoracic components were used, of which 6 were modified intraoperatively. Twenty-one renovisceral arteries were revascularized, using dedicated fenestrations (n = 10, 47.7%), chimney (n = 7, 33.3%), and snorkel stents (n = 4, 19%). The mean operative time was 326 ± 82 min including the device modification time. The mean time for graft modification was 90 ± 15 min. In 1 patient, a rescue chimney stent intended to the superior mesenteric artery was deployed because of failed cannulation through the dedicated fenestration. Technical success rate was 83.3%. One patient died during the early postoperative course from severe stroke. Among surviving patients, 3 required early reinterventions for iliac occluder-related type II endoleak (n = 1), type Ia endoleak (n = 1), and

  15. Endolymphatic Thoracic Duct Stent-Graft Reconstruction for Chylothorax: Approach, Technical Success, Safety, and Short-term Outcomes.

    Science.gov (United States)

    Srinivasa, Rajiv N; Chick, Jeffrey Forris Beecham; Hage, Anthony N; Gemmete, Joseph J; Murrey, Douglas C; Srinivasa, Ravi N

    2018-04-01

    To report approach, technical success, safety, and short-term outcomes of thoracic duct stent-graft reconstruction for the treatment of chylothorax. Two patients, 1 (50%) male and 1 (50%) female, with mean age of 38 years (range: 16-59 years) underwent endolymphatic thoracic duct stent-graft reconstruction between September 2016 and July 2017. Patients had radiographic left-sided chylothoraces (n = 2) from idiopathic causes (n = 1) and heart transplantation (n = 1). In both (100%) patients, antegrade lymphatic access was used to opacify the thoracic duct after which retrograde access was used for thoracic duct stent-graft placement. Pelvic lymphangiography technical success, antegrade cisterna chyli cannulation technical success, thoracic duct opacification technical success, retrograde thoracic duct access technical success, thoracic duct stent-graft reconstruction technical success, ethiodized oil volume, contrast volume, estimated blood loss, procedure time, fluoroscopy time, radiation dose, clinical success, complications, deaths, and follow-up were recorded. Pelvic lymphangiography, antegrade cisterna chyli cannulation, thoracic duct opacification, retrograde thoracic duct access, and thoracic duct stent-graft reconstruction were technically successful in both (100%) patients. Mean ethiodized oil volume was 8 mL (range: 5-10 mL). Mean contrast volume was 13 mL (range: 5-20 mL). Mean estimated blood loss was 13 mL (range: 10-15 mL). Mean fluoroscopy time was 50.4 min (range: 31.2-69.7 min). Mean dose area product and reference air kerma were 954.4 μGmy 2 (range: 701-1,208 μGmy 2 ) and 83.5 mGy (range: 59-108 mGy), respectively. Chylothorax resolved in both (100%) patients. There were no minor or major complications directly related to the procedure. Thoracic duct stent-graft reconstruction may be a technically successful and safe alternative to thoracic duct embolization, disruption, and surgical ligation for the treatment of chylothorax

  16. Results of a multicenter, prospective trial of thoracic endovascular aortic repair for blunt thoracic aortic injury (RESCUE trial).

    Science.gov (United States)

    Khoynezhad, Ali; Azizzadeh, Ali; Donayre, Carlos E; Matsumoto, Alan; Velazquez, Omaida; White, Rodney

    2013-04-01

    To evaluate the early outcomes of patients undergoing thoracic endovascular aortic repair for blunt thoracic aortic injuries. A prospective, nonrandomized, multicenter trial using the Medtronic Valiant Captivia stent graft was conducted at 20 sites in North America. Fifty patients with blunt thoracic aortic injuries were enrolled between April 2010 and January 2012 and will be followed for 5 years. The injuries were classified into categories (grades I-IV) based on severity: intimal tear, intramural hematoma, pseudoaneurysm, or rupture. The primary end point was 30-day all-cause mortality. Secondary end points were adverse events occurring within 30 days that were related to the procedure, device or aorta, and aortic-related mortality. Technical success was measured as successful device delivery and deployment. Seventy-six percent (38/50) of patients were male with mean age of 41 ± 17 years. Fifty-one Medtronic Valiant Captivia thoracic stent grafts and a single Talent thoracic stent graft were implanted within a median of 1.0 days following injury (mean, 1.8 ± 4.0 days). Seventy percent (35/50) of aortic injuries were grade III or higher, including one patient with free rupture. Mean injury severity score was 38 ± 14. Fifty-four percent of stent grafts were ≤26 mm (28/52). The left subclavian artery was completely covered in 40% of patients (20/50) and partially covered in 18% of patients (9/50). Four patients underwent subclavian artery revascularization: one at the time of the endograft procedure and three others after developing arm ischemia after the initial endograft procedure. Cerebral spinal fluid was drained in two patients. The median procedure time was 91 minutes, and median hospital stay was 12 days. There was 100% successful device delivery and deployment. Four (8%) patients died within 30 days. Nonfatal adverse events within 30 days that were related to the procedure, device, or aorta were experienced by 12% (6/50) of patients. No nonfatal

  17. Outcomes of AV Fistulas and AV Grafts after Interventional Stent-Graft Deployment in Haemodialysis Patients.

    Science.gov (United States)

    Schmelter, Christopher; Raab, Udo; Lazarus, Friedrich; Ruppert, Volker; Vorwerk, Dierk

    2015-08-01

    The study was designed to assess outcomes of arteriovenous (AV) accesses after interventional stent-graft deployment in haemodialysis patients. 63 haemodialysis patients with 66 AV fistulas and AV grafts were treated by interventional stent-graft deployment from 2006 to 2012 at our hospital. Data of these patients were retrospectively analysed for location of deployed stent-grafts, occurrence and location of (re-)stenosis and (re-)thrombosis. Complex stenosis was the most frequent indication for stent-graft deployment (45.5%), followed by complications of angioplasty with vessel rupture or dissection (31.8%). A high rate of procedural success was achieved (98.5%). The most frequent location of the deployed stent-graft was the draining vein (66.7%). Stent-graft deployment was more frequent in AV grafts than in AV fistulas. Primary patency was 45.5% at 6 month, 31.3% at 12 month and 19.2% at 24 month. Primary patency was significantly better for AV fistulas than for AV grafts with deployed stent-grafts. Patency of the deployed stent-graft was much better than overall AV access primary patency with deployed stent-graft. Re-stenosis with thrombosis was the most frequent indication for re-intervention. Most frequent location of re-stenosis was the draining vein (37.1%), followed by stenosis at the AV access (29.5%) and the deployed stent-graft (23.5%). Re-stenosis and re-thrombosis remain frequent in AV fistulas and AV grafts in haemodialysis patients despite stent-graft deployment. Re-stenosis of the deployed stent-graft is, only in the minority of the cases, responsible for AV access dysfunction.

  18. Outcomes of AV Fistulas and AV Grafts after Interventional Stent-Graft Deployment in Haemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Schmelter, Christopher, E-mail: christopher.schmelter@klinikum-ingolstadt.de; Raab, Udo, E-mail: udo.raab@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany); Lazarus, Friedrich, E-mail: friedrich.lazarus@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Nephrology (Germany); Ruppert, Volker, E-mail: volker.ruppert@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Vascular Surgery (Germany); Vorwerk, Dierk, E-mail: dierk.vorwerk@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany)

    2015-08-15

    PurposeThe study was designed to assess outcomes of arteriovenous (AV) accesses after interventional stent-graft deployment in haemodialysis patients.Materials and Methods63 haemodialysis patients with 66 AV fistulas and AV grafts were treated by interventional stent-graft deployment from 2006 to 2012 at our hospital. Data of these patients were retrospectively analysed for location of deployed stent-grafts, occurrence and location of (re-)stenosis and (re-)thrombosis. Complex stenosis was the most frequent indication for stent-graft deployment (45.5 %), followed by complications of angioplasty with vessel rupture or dissection (31.8 %).ResultsA high rate of procedural success was achieved (98.5 %). The most frequent location of the deployed stent-graft was the draining vein (66.7 %). Stent-graft deployment was more frequent in AV grafts than in AV fistulas. Primary patency was 45.5 % at 6 month, 31.3 % at 12 month and 19.2 % at 24 month. Primary patency was significantly better for AV fistulas than for AV grafts with deployed stent-grafts. Patency of the deployed stent-graft was much better than overall AV access primary patency with deployed stent-graft. Re-stenosis with thrombosis was the most frequent indication for re-intervention. Most frequent location of re-stenosis was the draining vein (37.1 %), followed by stenosis at the AV access (29.5 %) and the deployed stent-graft (23.5 %).ConclusionRe-stenosis and re-thrombosis remain frequent in AV fistulas and AV grafts in haemodialysis patients despite stent-graft deployment. Re-stenosis of the deployed stent-graft is, only in the minority of the cases, responsible for AV access dysfunction.

  19. EVAR of aortoiliac aneurysms with branched stent-grafts.

    Science.gov (United States)

    Dias, N V; Resch, T A; Sonesson, B; Ivancev, K; Malina, M

    2008-06-01

    Branched iliac stent-grafts (bSG) have recently been developed in order to preserve internal iliac artery (IIA) flow in patients with aneurysmal or short common iliac arteries. The aim of this study is to evaluate a single-center experience with bSG for the IIA. Twenty-two male patients (70 (IQR 65-79) years old) underwent EVAR with 23 bSG (1 bilateral repair) between September 2002 and August 2007. Median AAA diameter was 52 (37-60) mm while common iliac diameter on the side of the bSG was 34 (27-41) mm. Two in-house modified Zenith SG and subsequently 21 commercially available bSG (18 Zenith Iliac Side and 3 Helical Branches) were used. Follow-up (FU) included CT at one month and yearly thereafter. Data was prospectively entered in a database. Primary technical success was 91% (21 bSG). Median FU duration was 20 (8-31) months. One patient (5 %) died after discharge from acute myocardial infarction on day 13. Another patient died 30 months after EVAR of an unrelated cause. The overall bSG patency was 74% due to 6 branch occlusions (2 intraoperative and 4 late). All patients with patent bSG were asymptomatic. Three occlusions were asymptomatic findings on CT, while the other three developed claudication (two patients with contralateral IIA occlusion and one with simultaneous occlusion of the external iliac). One patient (5%) developed an asymptomatic type III endoleak at 1 month and was successfully treated with a bridging SG. Overall, four patients (18%) required reinterventions (1 bilateral stenting of the external iliac arteries, 1 external and 1 internal SG extensions and 1 femoro-femoral cross-over bypass). Nine out of 16 patients (56%) with CT-FU>/=1 year had shrinking aneurysms. There were no postoperative aneurysm expansions. EVAR of aortoiliac aneurysms with IIA bSG is a good alternative to occlusion of the IIA in patients with challenging distal anatomy.

  20. Miscellaneous Endovascular Treatment of Ruptured Hepatic Artery Pseudoaneurysms after Pylorus Preserving Pancreaticoduodenectomy

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ung Rae; Lee, Young Hwan [Dept. of Radiology, Daegu Catholic University Medical Center, Catholic of Daegu University School of Medicine, Daegu (Korea, Republic of); Ahn, Eun Joung; Kim, See Hyung; Kim, Young Hwan [Dept. of Radiology, Keimyung University Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2012-03-15

    To assess the feasibility and safety of the endovascular treatment of ruptured hepatic artery pseudoaneurysms after pylorus preserving pancreaticoduodenectomy (PPPD). Thirteen patients with hepatic artery pseudoaneurysm after PPPD were enrolled. Various endovascular techniques were used depending on the sites and morphologies of the pseudoaneurysms. Five cases were treated by coil embolization, five with stent-graft, one by thrombin injection and coil embolization, one with stent-graft and coil embolization, and one with N-butyl cyanoacrylate (NBCA) injection. Computed tomography scans and liver function test were performed after the procedures. Pseudoaneurysm exclusion and bleeding cessation was achieved in all patients. In four patients that underwent coil or NBCA embolization of the hepatic artery, aspartate transaminase (AST) and alanine transaminase (ALT) were markedly elevated. Two of these four patients with narrowing of the portal vein due to surrounding hematoma died of hepatic infarction or hepatic abscess. In other nine patients, AST and ALT were unchanged. In the 11 surviving patients, normal hepatic function and complete pseudoaneurysm disappearance were achieved during follow-up. Endovascular treatment of ruptured hepatic artery pseudoaneurysms can be considered as a feasible and safe method. However, complete occlusion of the hepatic artery with coils should be avoided in patients with inadequate portal flow.

  1. Endovascular Repair of Abdominal Aortic Aneurysms in the Presence of a Transplanted Kidney

    Energy Technology Data Exchange (ETDEWEB)

    Silverberg, Daniel, E-mail: silverberg-d@msn.com; Yalon, Tal; Halak, Moshe [The Chaim Sheba Medical Center, The Department of Vascular Surgery (Israel)

    2015-08-15

    PurposeTo present our experience performing endovascular repair of abdominal aortic aneurysms in kidney transplanted patients.MethodsA retrospective review of all patients who underwent endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms (AAA) performed at our institution from 2007 to 2014. We identified all patients who had previously undergone a kidney transplant. Data collected included: comorbidities, preoperative imaging modalities, indication for surgery, stent graft configurations, pre- and postoperative renal function, perioperative complications, and survival rates.ResultsA total of 267 EVARs were performed. Six (2 %) had a transplanted kidney. Mean age was 74 (range, 64–82) years; five were males. Mean time from transplantation to EVAR was 7.5 (range, 2–12) years. Five underwent preoperative planning with noncontrast modalities only. Devices used included bifurcated (n = 3), aortouniiliac (n = 2), and tube (n = 1) stent grafts. Technical success was achieved in all patients. None experienced deterioration in renal function. Median follow-up was 39 (range, 6–51) months. Four patients were alive at the time of the study. Two patients expired during the period of follow-up from unrelated causes.ConclusionsEVAR is an effective modality for the management of AAAs in the coexistence of a transplanted kidney. It can be performed with minimal morbidity and mortality without harming the transplanted kidney. Special consideration should be given to device configuration to minimize damage to the renal graft.

  2. Predictors of aortic growth in uncomplicated type B aortic dissection from the Acute Dissection Stent Grafting or Best Medical Treatment (ADSORB) database

    DEFF Research Database (Denmark)

    Kamman, Arnoud V; Brunkwall, Jan; Verhoeven, Eric L

    2017-01-01

    BACKGROUND: The high-risk patient cohort of uncomplicated type B aortic dissections (uTBADs) needs to be clarified. We compared uTBAD patients treated with best medical treatment (BMT), with and without aortic growth, from the Acute Dissection Stent Grafting or Best Medical Treatment (ADSORB) trial...... database. Furthermore, we looked for trends in outcome for aortic growth and remodeling after BMT and thoracic endovascular aortic repair (TEVAR) and BMT (TEVAR+BMT). METHODS: BMT patients with available baseline and a 1-year follow-up arterial computed tomography scan were identified. True lumen and false...

  3. Endovascular Management of Acute Bleeding Arterioenteric Fistulas

    International Nuclear Information System (INIS)

    Leonhardt, Henrik; Mellander, Stefan; Snygg, Johan; Loenn, Lars

    2008-01-01

    The objective of this study was to review the outcome of endovascular transcatheter repair of emergent arterioenteric fistulas. Cases of abdominal arterioenteric fistulas (defined as a fistula between a major artery and the small intestine or colon, thus not the esophagus or stomach), diagnosed over the 3-year period between December 2002 and December 2005 at our institution, were retrospectively reviewed. Five patients with severe enteric bleeding underwent angiography and endovascular repair. Four presented primary arterioenteric fistulas, and one presented a secondary aortoenteric fistula. All had massive persistent bleeding with hypotension despite volume substitution and transfusion by the time of endovascular management. Outcome after treatment of these patients was investigated for major procedure-related complications, recurrence, reintervention, morbidity, and mortality. Mean follow-up time was 3 months (range, 1-6 months). All massive bleeding was controlled by occlusive balloon catheters. Four fistulas were successfully sealed with stent-grafts, resulting in a technical success rate of 80%. One patient was circulatory stabilized by endovascular management but needed immediate further open surgery. There were no procedure-related major complications. Mean hospital stay after the initial endovascular intervention was 19 days. Rebleeding occurred in four patients (80%) after a free interval of 2 weeks or longer. During the follow-up period three patients needed reintervention. The in-hospital mortality was 20% and the 30-day mortality was 40%. The midterm outcome was poor, due to comorbidities or rebleeding, with a mortality of 80% within 6 months. In conclusion, endovascular repair is an efficient and safe method to stabilize patients with life-threatening bleeding arterioenteric fistulas in the emergent episode. However, in this group of patients with severe comorbidities, the risk of rebleeding is high and further intervention must be considered

  4. Juxtarenal Modular Aortic Stent Graft Infection Caused by Staphylococcus aureus

    Directory of Open Access Journals (Sweden)

    Róbert Novotný

    2016-01-01

    Full Text Available Introduction. We are presenting a case report of an infected modular abdominal stent graft. Case Presentation. A 67-year-old male patient three years after Cook’s modular abdominal aortic aneurysm (AAA graft implantation for juxtarenal AAA with an implantation of a stent extension into the right common iliac artery for type Ib endoleak. The patient was admitted into our center in severe condition with suspected retroperitoneal bleeding. Computed tomography angiography (CTAG confirmed retroperitoneal bleeding in the right common iliac artery. An urgent surgical revision was indicated; destructed arterial wall around the stent extension in the right common iliac artery was discovered. Due to the severe state of health of the patient, a resection of the infected stent and affected arterial wall was performed, followed by an iliac-femoral crossover bypass. The patient was transported to the intensive care unit with hepatic and renal failure, with maximal catecholamine support. Combined antibiotic treatment was started. The patient died five hours after the procedure. The cause of death was multiorgan failure caused by sepsis. Hemocultures and perioperative microbiological cultures showed the infection agent to be Staphylococcus aureus methicillin sensitive. Conclusion. Stent graft infection is a rare complication. Treatment is associated with high mortality and morbidity.

  5. Outcome of renal stenting for renal artery coverage during endovascular aortic aneurysm repair.

    Science.gov (United States)

    Hiramoto, Jade S; Chang, Catherine K; Reilly, Linda M; Schneider, Darren B; Rapp, Joseph H; Chuter, Timothy A M

    2009-05-01

    This study was conducted to determine the outcome of adjunctive renal artery stenting for renal artery coverage at the time of endovascular abdominal aortic aneurysm repair (EVAR). Between August 2000 and August 2008, 29 patients underwent elective EVAR using bifurcated Zenith stent grafts (Cook, Indianapolis, Ind) and simultaneous renal artery stenting. Renal artery stenting during EVAR was performed with endograft "encroachment" on the renal artery ostium (n = 23) or placement of a renal stent parallel to the main body of the endograft ("snorkel," n = 8). Follow-up included routine contrast-enhanced computed tomography (CT), multiview abdominal radiographs, and serum creatinine measurement at 1, 6, and 12 months, and then yearly thereafter. Thirty-one renal arteries were stented successfully in 29 patients. The 18 patients with planned renal artery stent placement had a proximal neck length technique (6.9 +/- 3.1 mm) compared with those with planned endograft encroachment (9.9 +/- 2.6 mm). None of the patients with unplanned endograft encroachment had neck lengths 1 month postoperatively) or stent graft migrations. Adjunctive renal artery stenting during endovascular AAA repair using the "encroachment" and "snorkel" techniques is safe and effective. Short- and medium-term primary patency rates are excellent, but careful follow-up is needed to determine the durability of these techniques.

  6. Early Results with the Use of Heparin-bonded Stent Graft to Rescue Failed Angioplasty of Chronic Femoropopliteal Occlusive Lesions: TASC D Lesions Have a Poor Outcome

    Energy Technology Data Exchange (ETDEWEB)

    Kuhan, Ganesh, E-mail: gkuhan@nhs.net; Abisi, Said; Braithwaite, Bruce D.; MacSweeney, Shane T. R. [Nottingham University Hospitals, Vascular and Endovascular Unit, Queens Medical Centre (United Kingdom); Whitaker, Simon C.; Habib, Said B. [Nottingham University Hospitals, Department of Radiology, Queen' s Medical Centre (United Kingdom)

    2012-10-15

    Purpose: To evaluate early patency rate of the heparin-bonded stent grafts in atherosclerotic long femoropopliteal occlusive disease, and to identify factors that affect outcome. Methods: Heparin-bonded Viabahn stent grafts were placed in 33 limbs in 33 patients during 2009-2010. The stents were deployed to rescue failed conventional balloon angioplasty. Mean age was 69 (range 44-88) years, and 67 % (22 of 33) were men. Most procedures (21 of 33, 64 %) were performed for critical limb ischemia (33 % for rest pain, 30 % tissue loss). Kaplan-Meier plots and Cox regression analysis were used to identify significant risk factors. Results: The average length of lesions treated was 25 {+-} 10 cm, and they were predominantly TASC (Transatlantic Intersociety Consensus) D (n = 13) and C (n = 17) lesions. The median primary patency was 5.0 months (95 % confidence interval 1.22-8.77). The mean secondary patency was 8.6 months (95 % confidence interval 6.82-10.42). Subsequently, 4 patients underwent bypass surgery and 5 patients underwent major amputation. One patient died. There were 5 in-stent or edge-stent stenoses. Cox multivariate regression analysis identified TASC D lesions to be a significant risk factor for early occlusion (p = 0.035). Conclusion: TASC D lesions of femoropopliteal occlusions have poor patency rates with the use of heparin-bonded stent grafts after failed conventional angioplasty. Alternative options should be considered for these patients.

  7. Late Complication after Superficial Femoral Artery (SFA) Aneurysm: Stent-graft Expulsion Outside the Skin.

    Science.gov (United States)

    Pecoraro, Felice; Sabatino, Ermanno R; Dinoto, Ettore; La Rosa, Giuliana; Corte, Giuseppe; Bajardi, Guido

    2015-10-01

    A 78-year-old man presented with a 7-cm aneurysm in the left superficial femoral artery, which was considered unfit and anatomically unsuitable for conventional open surgery for multiple comorbidities. The patient was treated with stent-graft [Viabhan stent-graft (WL Gore and Associates, Flagstaff, AZ)]. Two years from stent-graft implantation, the patient presented a purulent secretion and a spontaneous external expulsion through a fistulous channel. No claudication symptoms or hemorrhagic signs were present. The pus and device cultures were positive for Staphylococcus aureus sensitive to piperacillin/tazobactam. Patient management consisted of fistula drainage, systemic antibiotic therapy, and daily wound dressing. At 1-month follow-up, the wound was closed. To our knowledge, this is the first case of this type of stent-graft complication presenting with external expulsion.

  8. Late Complication after Superficial Femoral Artery (SFA) Aneurysm: Stent-graft Expulsion Outside the Skin

    Energy Technology Data Exchange (ETDEWEB)

    Pecoraro, Felice, E-mail: felicepecoraro@libero.it; Sabatino, Ermanno R.; Dinoto, Ettore; Rosa, Giuliana La; Corte, Giuseppe; Bajardi, Guido [University of Palermo, Vascular Surgery Unit (Italy)

    2015-10-15

    A 78-year-old man presented with a 7-cm aneurysm in the left superficial femoral artery, which was considered unfit and anatomically unsuitable for conventional open surgery for multiple comorbidities. The patient was treated with stent-graft [Viabhan stent-graft (WL Gore and Associates, Flagstaff, AZ)]. Two years from stent-graft implantation, the patient presented a purulent secretion and a spontaneous external expulsion through a fistulous channel. No claudication symptoms or hemorrhagic signs were present. The pus and device cultures were positive for Staphylococcus aureus sensitive to piperacillin/tazobactam. Patient management consisted of fistula drainage, systemic antibiotic therapy, and daily wound dressing. At 1-month follow-up, the wound was closed. To our knowledge, this is the first case of this type of stent-graft complication presenting with external expulsion.

  9. Endovascular surgery in Marfan syndrome: CON.

    Science.gov (United States)

    Kouchoukos, Nicholas T

    2017-11-01

    The frequency of endovascular stent grafting procedures to treat various conditions of the thoracic aorta has increased dramatically over the past three decades. Stent grafting has been applied on a limited basis in patients with Marfan syndrome and other connective tissue disorders, despite recommendations from current guidelines and expert consensus statements against its use in this setting. A review of publications reporting outcomes after stent grafting of the descending thoracic aorta in Marfan patients with acute or chronic aortic dissection indicates that these procedures can be accomplished with rates of early mortality, stroke and spinal cord ischemic injury that are comparable to those observed in patients who do not have Marfan syndrome. However, the rates of primary treatment failure (principally endoleak), secondary treatment failure, need for open repair and late death among the Marfan patients are substantially higher than those observed in patients without this condition. In addition, the rates of retrograde aortic dissection and development of stent-graft induced new entry (SINE), are also greater among patients with Marfan syndrome. All of these findings argue strongly against the routine use of endovascular grafts in Marfan patients with type B or residual type A dissection. Few data are available to assess the role of endografting in Marfan patients with aneurysmal disease, but the progressive aortic dilatation noted in these patients argues strongly against its use in this setting as well. At present, the available data indicate that there is no justification for elective stent grafting in Marfan patients with aortic dissection or aneurysm. The only reasonable indications for primary aortic stent grafting are in the setting of acute aortic dissection or rupture, where the intervention is considered life-saving and rarely, considering the relatively young age of these patients, where the risk of open operation is considered to be prohibitive.

  10. Multidetector-Row Computed Tomography in the Evaluation of Transjugular Intrahepatic Portosystemic Shunt Performed with Expanded-Polytetrafluoroethylene-Covered Stent-Graft

    International Nuclear Information System (INIS)

    Fanelli, Fabrizio; Bezzi, Mario; Bruni, Antonio; Corona, Mario; Boatta, Emanuele; Lucatelli, Pierleone; Passariello, Roberto

    2011-01-01

    We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound–color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findings and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.

  11. Late Pseudocoarctation Syndrome After Stent-Graft Implantation For Traumatic Aortic Rupture

    International Nuclear Information System (INIS)

    Letocart, Vincent; Fau, Georges; Tirouvanziam, Ashok; Toquet, Claire; Al Habash, Oussama; Guerin, Patrice; Rousseau, Hervé; Crochet, Dominique

    2013-01-01

    The present observation illustrates an unusual complication occurring after stent-grafting (S-graft) for aortic isthmus rupture. A 22-year-old patient, treated by S-graft in the emergency department for traumatic aortic rupture, was readmitted 10 months later with pseudocoarctation syndrome. A membrane was found inside the stent-graft that had induced a pseudo-dissection, which caused the pseudocoarctation syndrome. Surgical treatment consisted of removing the stent-graft and membrane and replacing it with a vascular implant. The patient’s clinical course was fair. The suggested mechanism was circumferential neoendothelialization of the stent-graft. Dehiscence caused the superior part of the membrane to drop into the lumen of the stent-graft creating a “false channel” that compressed the “true lumen” and induced “pseudocoarctation” syndrome. The cause of the extensive neointimalization remains unexplained. Thoracic aortic stent-grafts require regular follow-up monitoring by angioscan or angio-magnetic resonance imaging.

  12. Late Pseudocoarctation Syndrome After Stent-Graft Implantation For Traumatic Aortic Rupture

    Energy Technology Data Exchange (ETDEWEB)

    Letocart, Vincent, E-mail: vincent.letocart@chu-nantes.fr; Fau, Georges, E-mail: georges.fau@chu-nantes.fr; Tirouvanziam, Ashok, E-mail: ashok.tirouvanziam@chu-nantes.fr [University Hospital of Nantes, Institut du Thorax (France); Toquet, Claire, E-mail: claire.toquet@chu-nantes.fr [University Hospital of Nantes, Department of Pathology (France); Al Habash, Oussama, E-mail: oussama.alhabash@chu-nantes.fr; Guerin, Patrice, E-mail: patrice.guerin@chu-nantes.fr [University Hospital of Nantes, Institut du Thorax (France); Rousseau, Herve, E-mail: rousseau.h@chu-toulouse.fr [University Hospital of Toulouse, Department of Radiology (France); Crochet, Dominique, E-mail: dominique.crochet@chu-nantes.fr [University Hospital of Nantes, Institut du Thorax (France)

    2013-06-15

    The present observation illustrates an unusual complication occurring after stent-grafting (S-graft) for aortic isthmus rupture. A 22-year-old patient, treated by S-graft in the emergency department for traumatic aortic rupture, was readmitted 10 months later with pseudocoarctation syndrome. A membrane was found inside the stent-graft that had induced a pseudo-dissection, which caused the pseudocoarctation syndrome. Surgical treatment consisted of removing the stent-graft and membrane and replacing it with a vascular implant. The patient's clinical course was fair. The suggested mechanism was circumferential neoendothelialization of the stent-graft. Dehiscence caused the superior part of the membrane to drop into the lumen of the stent-graft creating a 'false channel' that compressed the 'true lumen' and induced 'pseudocoarctation' syndrome. The cause of the extensive neointimalization remains unexplained. Thoracic aortic stent-grafts require regular follow-up monitoring by angioscan or angio-magnetic resonance imaging.

  13. Retrograde type A dissection following hybrid supra-aortic endovascular surgery in high-risk patients unfit for conventional open repair.

    Science.gov (United States)

    Yip, Hon C; Chan, Yiu C; Qing, Kai X; Cheng, Stephen W

    2018-04-01

    Hybrid procedures with combined open extra-anatomical supra-aortic bypasses and endovascular surgery are less invasive for patients with complex aortic arch pathology. The aim of this paper is to report patients who developed retrograde type A aortic dissection following initially successful hybrid endovascular treatment. Retrospective review of prospectively collected computerized departmental database. All patients with supra-aortic hybrid endovascular surgery and post-procedure retrograde type A dissection were identified. Patient demographics, comorbid conditions, perioperative parameters, procedural details and post-operative complications were collected. From May 2005 to July 2014, 163 patients underwent thoracic aortic endovascular procedures at our institution. From the 46 patients who had supra-aortic hybrid endovascular repair, six patients (6/46, 13% of all supra-aortic hybrid cases, 3 males) developed retrograde type A aortic dissection. All were elective cases, with 3 chronic dissecting aneurysms and 3 atherosclerotic aneurysms. All had one-stage hybrid procedures: 2 patients had carotid-carotid bypass grafts, one had carotid-carotid-left subclavian bypass graft, and 3 had bypass grafts from ascending aorta to innominate artery and left carotid artery. Five patients had Cook Zenith thoracic stent-grafts (Cook Medical, Bloomington, IN, USA), and one had Medtronic Valiant stent-grafts (Medtronic Vascular Inc, Santa Rosa, CA, USA). The retrograde type A dissection occurred with sudden symptoms at day 5, 6, 10, 20, 105 and 128, respectively. There were 3 immediate fatalities and 2 patients treated conservatively deemed unfit for reintervention (one died of pneumonia at 9 months, and one remained alive at 7 months post-complication). One patient underwent successful emergency open surgery and survived. Supra-aortic hybrid procedures in treating aortic arch pathology may be at risk of developing retrograde type A dissection. This post-operative complication

  14. A Novel Attempt to Standardize Results of CFD Simulations Basing on Spatial Configuration of Aortic Stent-Grafts.

    Directory of Open Access Journals (Sweden)

    Andrzej Polanczyk

    Full Text Available Currently, studies connected with Computational Fluid Dynamic (CFD techniques focus on assessing hemodynamic of blood flow in vessels in different conditions e.g. after stent-graft's placement. The paper propose a novel method of standardization of results obtained from calculations of stent-grafts' "pushing forces" (cumulative WSS--Wall Shear Stress, and describes its usefulness in diagnostic process. AngioCT data from 27 patients were used to reconstruct 3D geometries of stent-grafts which next were used to create respective reference cylinders. We made an assumption that both the side surface and the height of a stent-graft and a reference cylinder were equal. The proposed algorithm in conjunction with a stent-graft "pushing forces" on an implant wall, allowed us to determine which spatial configuration of a stent-graft predispose to the higher risk of its migration. For stent-grafts close to cylindrical shape (shape factor φ close to 1 WSS value was about 267 Pa, while for stent-grafts different from cylindrical shape (φ close to 2 WSS value was about 635 Pa. It was also noticed that deformation in the stent-graft's bifurcation part impaired blood flow hemodynamic. Concluding the proposed algorithm of standardization proved its usefulness in estimating the WSS values that may be useful in diagnostic process. Angular bends or tortuosity in bifurcations of an aortic implant should be considered in further studies of estimation of the risk of implantation failure.

  15. Endovascular repair of the ascending aorta: when and how to implement the current technology.

    Science.gov (United States)

    Preventza, Ourania; Henry, Matthew J; Cheong, Benjamin Y C; Coselli, Joseph S

    2014-05-01

    The purpose of our study was to examine when and how to implement the current endoluminal stent graft technology to treat ascending aortic disease. During a 7-year period (March 2006 through July 2013), 7 consecutive patients (median age, 69 years; range, 61.5 to 80.5 years) with multiple comorbidities underwent endoluminal repair of the ascending aorta. Six had an ascending aortic pseudoaneurysm, and 1 had iatrogenic coarctation. The median number of prior sternotomies was 2 (range, 1 to 4). Technical success was achieved in all but 1 patient, with 1 death (14.3%) at 30 days. The endoluminal technology used included the Gore TAG (W.L. Gore and Associates, Flagstaff, AZ) thoracic graft (including the new C-TAG) in 6 patients, the Talent stent graft (Medtronic, Santa Rosa, CA) in 1, an Excluder cuff (W.L. Gore) in 2, and an Amplatzer occluder (AGA Medical Corp, Plymouth, MN) in 1. More than 1 stent was placed in 4 patients. Three patients required innominate artery stenting, and 1 required additional left common carotid artery stenting. One patient (14.3%) required intraoperative conversion to open surgical repair. Median follow-up was 14.4 months (interquartile [25th to 75th percentile] range, 5.5 to 22.6 months) with 66.6% overall survival. No aortic-related death was reported during the follow-up period. Stent grafting of the ascending aorta is feasible but limited and is reserved for high-risk individuals. Technical expertise is essential, and follow-up is mandatory. Technical points, tips, and challenges of the current endovascular technology to effectively treat the ascending aorta are described. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Noninvasive evaluation of the effectiveness of endovascular AAA exclusion.

    NARCIS (Netherlands)

    Laan, M.J. van der; Teutelink, A.; Wixon, C.L.; Blankensteijn, J.D.

    2003-01-01

    PURPOSE: To evaluate the relationship between aneurysm sac pressure and endograft wall motion in vitro and in vivo and to compare this to sac volume changes after endovascular aneurysm repair. METHODS: In a flow model of an aneurysm with a stent-graft in situ, sac pressure was incrementally

  17. The hybrid stent-graft technique: a solution to complex aortic problems and lessons learned.

    Science.gov (United States)

    Kokotsakis, John; Misthos, Panagiotis; Athanasiou, Thanos; Sakellaridis, Timotheos; Neofotistos, Kostas; Skouteli, Elian; Lioulias, Achilleas

    2008-01-01

    The frozen elephant trunk technique has been recently presented in the literature and has been considered as a novel surgical option for single-stage repair of complex aortic pathology such as combined arch and descending thoracic aortic aneurysms. The first patient, a 74-year-old male, was admitted severely symptomatic (interscapular pain), with aortic distal arch and proximal descending thoracic aortic aneurysm with a diameter of 6 cm. The second patient, a 72-year-old male, underwent descending aortic aneurysm stent grafting one year ago and was admitted gravely symptomatic (interscapular pain), with aortic arch aneurysm (diameter of 5.7 cm) and type I endoleak at the proximal end of the stent. The first patient developed paraplegia after the operation and died three months after the operation due to pneumonia while he was on a rehabilitation program. The second patient's recovery was uneventful and was discharged on postoperative day nine. This report summarizes our preliminary experience with this technique emphasizing two points: first, it offers the opportunity to manage efficiently complex aortic problems, and second, there is a potential risk of serious complications related to the limited stent sizes available of the device to match the patient's anatomical characteristics and pathology.

  18. Early and long-term clinical and radiological follow-up results of expanded-polytetrafluoroethylene-covered stent-grafts for transjugular intrahepatic portosystemic shunt procedures

    International Nuclear Information System (INIS)

    Maleux, Geert; Heye, Sam; Thijs, Maria; Wilms, Guy; Nevens, Frederik; Verslype, Chris; Wilmer, Alexander

    2004-01-01

    The purpose of this study was to assess the therapeutic efficacy and immediate and long-term safety of expanded-tetrafluoroethylene covered stent-grafts for transjugular intrahepatic portosystemic shunts in patients with portal hypertension-related complications. A cohort of 56 patients suffering from severe portal hypertension-related complications underwent implantation of an expanded-polytetrafluoroethylene-covered stent-graft. All patients suffered from severe liver cirrhosis graded Child-Pugh A (n=8; 16%), B (n=13; 21%) or C (n=35; 63%). In 44 patients, the stent-graft was placed during the initial TIPS procedure (de novo TIPS); in the other 12 patients, the stent-graft was placed to repermeabilize the previously placed bare stent (TIPS revision). Follow-up was performed with clinical assessment, duplex ultrasound and, if abnormal or inconclusive, with invasive venography and pressure measurements. Per- en immediate post-procedural complications occurred in four patients (4/56, 7%). None of them was lethal. During follow-up, stent occlusion appeared in one patient and stenosis in two; no recurrence of bleeding was noted in all patients treated for variceal bleeding (n=28), and 24 of the 28 patients (86%) suffering from refractory ascites and/or hepatic hydrothorax were free of regular paracenteses and/or drainage of pleural effusion after shunt creation. The 30-day and global mortality for the total study population (n=56) was, respectively, 7% (n=4) and 28.5% (n=16). In the patient subgroup with variceal bleeding (n=28), 30-day mortality was 3.5% (n=1) and global mortality 14.2% (n=4). In the ascites and/or hydrothorax subgroup (n=28), 8.1% (n=3) mortality at 30 days was found and global mortality was 32.4% (n=12). In 10 patients of the 56 studied patients (18%), isolated hepatic encephalopathy occurred, which was lethal in 4 (Child C) patients (7%). Three of these four patients died within the 1st month after TIPS placement. A very high primary patency rate

  19. Early and long-term clinical and radiological follow-up results of expanded-polytetrafluoroethylene-covered stent-grafts for transjugular intrahepatic portosystemic shunt procedures

    Energy Technology Data Exchange (ETDEWEB)

    Maleux, Geert; Heye, Sam; Thijs, Maria; Wilms, Guy [University Hospitals Gasthuisberg, Department of Radiology, Leuven (Belgium); Nevens, Frederik; Verslype, Chris [University Hospitals Gasthuisberg, Department of Hepatology, Leuven (Belgium); Wilmer, Alexander [University Hospitals Gasthuisberg, Department of Medical Intensive Care Unit, Leuven (Belgium)

    2004-10-01

    The purpose of this study was to assess the therapeutic efficacy and immediate and long-term safety of expanded-tetrafluoroethylene covered stent-grafts for transjugular intrahepatic portosystemic shunts in patients with portal hypertension-related complications. A cohort of 56 patients suffering from severe portal hypertension-related complications underwent implantation of an expanded-polytetrafluoroethylene-covered stent-graft. All patients suffered from severe liver cirrhosis graded Child-Pugh A (n=8; 16%), B (n=13; 21%) or C (n=35; 63%). In 44 patients, the stent-graft was placed during the initial TIPS procedure (de novo TIPS); in the other 12 patients, the stent-graft was placed to repermeabilize the previously placed bare stent (TIPS revision). Follow-up was performed with clinical assessment, duplex ultrasound and, if abnormal or inconclusive, with invasive venography and pressure measurements. Per- en immediate post-procedural complications occurred in four patients (4/56, 7%). None of them was lethal. During follow-up, stent occlusion appeared in one patient and stenosis in two; no recurrence of bleeding was noted in all patients treated for variceal bleeding (n=28), and 24 of the 28 patients (86%) suffering from refractory ascites and/or hepatic hydrothorax were free of regular paracenteses and/or drainage of pleural effusion after shunt creation. The 30-day and global mortality for the total study population (n=56) was, respectively, 7% (n=4) and 28.5% (n=16). In the patient subgroup with variceal bleeding (n=28), 30-day mortality was 3.5% (n=1) and global mortality 14.2% (n=4). In the ascites and/or hydrothorax subgroup (n=28), 8.1% (n=3) mortality at 30 days was found and global mortality was 32.4% (n=12). In 10 patients of the 56 studied patients (18%), isolated hepatic encephalopathy occurred, which was lethal in 4 (Child C) patients (7%). Three of these four patients died within the 1st month after TIPS placement. A very high primary patency rate

  20. Treatment of Acute Aortic Type B Dissection with Stent-Grafts

    International Nuclear Information System (INIS)

    Hausegger, K.A.; Tiesenhausen, K.; Schedlbauer, P.; Oberwalder, P.; Tauss, J.; Rigler, B.

    2001-01-01

    Purpose: To evaluate the feasibility of endoluminal stent-grafts in the treatment of acute type B aortic dissections.Methods: In five patients with acute aortic type B dissections, sealing of the primary intimal tear with an endoluminal stent-graft was attempted. Indication for treatment was aneurysm formation in two patients and persistent pain in three patients. One of the latter also had an unstable dissection flap compromising the ostium of the superior mesenteric artery. The distance from the intimal tear to the left subclavian artery was <0.5 cm in four patients, who had typical type B dissections. In one patient with an atypical dissection the distance from the primary tear to the left subclavian artery was 4 cm. This patient had no re-entry tear. Talent tube grafts (World Medical Manufacturing Cooperation, Sunrise, FL, USA) were used in all patients.Results: Stent-graft insertion with sealing of the primary tear was successful in all patients. The proximal covered portion of the stent-graft was placed across the left subclavian artery in four patients (1x transposition of the left subclavian artery). Left arm perfusion was preserved via a subclavian steal phenomenon in the patients in whom the stent-graft covered the orifice of the left subclavian artery. The only procedural complication we observed was an asymptomatic segmental renal infarction in one patient. In the thoracic aorta thrombosis of the false aortic lumen occurred in all patients. In one patient the false lumen of the abdominal aorta thrombosed after 4 weeks; in the other three patients the status of the abdominal aorta remained unchanged compared with the situation prior to stent-graft insertion. As a late complication formation of a secondary aneurysm of the thoracic aorta was observed at the distal end of the stent-graft 3 months after the primary intervention. This aneurysm was treated by coaxial insertion of an additional stent-graft without complications.Conclusion: Endoluminal treatment

  1. Balloon-Expandable Stent Graft for Treating Uretero-Iliac Artery Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Guntau, Moritz, E-mail: guntau@med.uni-marburg.de [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hegele, Axel [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Rheinheimer, Stephan [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hofmann, Rainer [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Mahnken, Andreas H. [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany)

    2017-06-15

    PurposeTo evaluate the safety, efficacy and outcome of percutaneous balloon-expandable covered stent graft placement for uretero-iliac artery fistula (UAF) treatment.MethodsThis retrospective study evaluated the single-center experience of percutaneous balloon-expandable covered stent graft placement (ADVANTA™, Atrium Hudson, NH, USA) in UAF. Data were obtained from a prospective institutional database. Patient follow-up included complications, symptoms recurrence and mortality rate.ResultsTen UAFs in eight patients (3 males; 5 females) with a mean age of 64.5 (35–77) years were identified. All patients had a history pelvic malignancy, extirpative surgery (n = 6), long-term ureteral stenting (n = 7) and pelvic radiation (n = 5). All procedures were completed successfully without complications. Thirty-day mortality rate was zero. At a median follow-up of 6 (1–60) months, one patient suffered recurrent hematuria requiring a secondary stent graft placement 26 months after the initial treatment. During follow-up, five patients died of the underlying disease (43, 66, 105, and 183 and 274 days after the last procedure).ConclusionPercutaneous balloon-expandable stent graft placement in UAF is a safe and effective treatment option. Implantation of stent grafts should be considered as treatment of choice in UAF.

  2. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    International Nuclear Information System (INIS)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua; Pfister, Roman; Deppe, Antje-Christin; Matoussevitch, Vladimir

    2014-01-01

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  3. A Pilot Study of Open Venous Revascularization using Expandable PTFE Stent Grafts in a Porcine (Sus scrofa) Model

    Science.gov (United States)

    2017-05-23

    expandable stent-grafts that are designed to expand within a vessel to cover an injury or open a blockage. Methods: 3 Yorkshire cross swine were...expandable PTFE stent graft was deployed into the vessel in an open direct fashion . The swine were awoken and allowed to ambulate. At 72 hours, conduit

  4. Use of a Stent Graft for Bleeding Hepatic Artery Pseudoaneurysm Following Pancreaticoduodenectomy

    Directory of Open Access Journals (Sweden)

    Leoncio L. Kaw, Jr

    2006-10-01

    Full Text Available Although uncommon, bleeding following pancreaticoduodenectomy is associated with high mortality. Management generally includes surgical reexploration or, alternatively, transarterial embolization. We report the case of a 62-year-old man who presented with massive upper gastrointestinal bleeding 3 weeks after pancreaticoduodenectomy. Selective coeliac angiography revealed a large pseudoaneurysm involving the proper hepatic artery. This was treated successfully with a stent graft. There was no recurrence of bleeding at the 6-month follow-up. To our knowledge, this is the first report of stent graft repair of bleeding hepatic artery pseudoaneurysm following pancreaticoduodenectomy.

  5. Emergency Stent Grafting After Unsuccessful Surgical Repair of a Mycotic Common Femoral Artery Pseudoaneurysm in a Drug Abuser

    International Nuclear Information System (INIS)

    Lupattelli, Tommaso; Garaci, Francesco Giuseppe; Basile, Antonio; Minnella, Daniela Paola; Casini, Andrea; Clerissi, Jacques

    2009-01-01

    Mycotic false aneurysm caused by local arterial injury from attempted intravenous injections in drug addicts remains a challenging clinical problem. The continued increase in drug abuse has resulted in an increased incidence of this problem, particularly in high-volume urban centres. In the drug-abusing population, mycotic arterial pseudoaneurysms most often occur because of missed venous injection and are typically seen in the groin, axilla, and antecubital fossa. Mycotic aneurysms may lead to life-threatening haemorrhage, limb loss, sepsis, and even death. Any soft-tissue swelling in the vicinity of a major artery in an intravenous drug abuser should be suspected of being a false aneurysm until proven otherwise and should prompt immediate referral to a vascular surgeon for investigation and management. We report a case of rupturing mycotic pseudoaneurysm of the left common femoral artery treated by surgical resection followed by vessel reconstruction with autologous material. Unfortunately, at the time of discharge a sudden leakage from the vein graft anastomosis occurred, with subsequent massive bleeding, and required emergent endovascular covered stenting. To the best of our knowledge, this is the first reported case of femoral artery bleeding in a drug abuser treated by stent graft placement.

  6. Transvenous Embolization of a Spontaneous Femoral AVF 5 Years After an Incomplete Treatment with Arterial Stent-Grafts

    International Nuclear Information System (INIS)

    Peynircioglu, Bora; Ozkan, Murat; Dogan, Omer Faruk; Cil, Barbaros E.; Dogan, Riza

    2008-01-01

    A 66-year-old man with complex left femoral arterio-venous fistula (AVF) was first diagnosed after a deep venous thrombosis incident approximately 5 years ago. Partial treatment was performed by means of endografts along the superficial femoral artery, which remained patent for 5 years. The patient had been doing well until a couple of months ago when he developed severe venous stasis and ulcers of the left cruris, due to a high-flow nonhealing complex AVF with additional iliac vein occlusion. Therefore; the definitive treatment was performed by a unique endovascular technique combined with surgical venous bypass (femoro-femoral crossover saphenous bypass, the Palma operation). A novel percutaneous transvenous technique for occlusion of a complex high-flow AVF is reported with a review of the literature. The case is unique with spontaneous AVF, transvenous embolization with detachable coils and ONYX, and the hybrid treatment technique as well as the long-term patency of superficial femoral artery stent-grafts

  7. Cephalic Arch Stenosis in Autogenous Haemodialysis Fistulas: Treatment With the Viabahn Stent-Graft

    Energy Technology Data Exchange (ETDEWEB)

    Shawyer, Andrew, E-mail: andrew.shawyer@bartsandthelondon.nhs.uk [The Royal London Hospital, Radiology Department (United Kingdom); Fotiadis, Nicos I., E-mail: fotiadis.nicholas@gmail.com [Royal Marsden Hospital, Radiology Department, The Royal Marsden NHS Foundation Trust (United Kingdom); Namagondlu, Girish, E-mail: girish.namagondlu@bartsandthelondon.nhs.uk [The Royal London Hospital, Renal Medicine Department (United Kingdom); Iyer, Arun, E-mail: arun.iyer@bartsandthelondon.nhs.uk [The Royal London Hospital, Radiology Department (United Kingdom); Blunden, Mark, E-mail: mark.blunden@bartsandthelondon.nhs.uk; Raftery, Martin, E-mail: martin.raftery@bartsandthelondon.nhs.uk; Yaqoob, Magdi, E-mail: magdi.yaqoob@bartsandthelondon.nhs.uk [The Royal London Hospital, Renal Medicine Department (United Kingdom)

    2013-02-15

    Cephalic arch stenosis (CAS) is an important and common cause of dysfunction in autogenous haemodialysis fistulas that requires multiple reinterventions and aggressive surveillance. We evaluated the safety and efficacy of the Viabahn stent-graft for the management of CAS. Between April 2005 and October 2011, 11 consecutive patients [four men and seven women (mean age 56.7 years)] with CAS and dysfunctional fistulas were treated with insertion of 11 Viabahn stent-grafts. Six stent-grafts were inserted due to residual stenosis after angioplasty and five for fistuloplasty-induced rupture. No patient was lost to follow-up. The technical and clinical success rate was 100 %. Primary access patency rates were 81.8 % [95 % confidence interval (CI) 0.482-0.977] at 6 months and 72.7 % (95 % CI 0.390-0.939) at 12 months. Secondary access patency rates were 90.9 % at 6 months (95 % CI 0.587-0.997). There were no procedure-related complications. Mean follow-up was 543.8 days (range 156-2,282). The use of the Viabahn stent-graft in the management of CAS is technically feasible and, in this small series, showed patency rates that compare favorably with historical data of angioplasty and bare stents.

  8. Cephalic Arch Stenosis in Autogenous Haemodialysis Fistulas: Treatment With the Viabahn Stent-Graft

    International Nuclear Information System (INIS)

    Shawyer, Andrew; Fotiadis, Nicos I.; Namagondlu, Girish; Iyer, Arun; Blunden, Mark; Raftery, Martin; Yaqoob, Magdi

    2013-01-01

    Cephalic arch stenosis (CAS) is an important and common cause of dysfunction in autogenous haemodialysis fistulas that requires multiple reinterventions and aggressive surveillance. We evaluated the safety and efficacy of the Viabahn stent-graft for the management of CAS. Between April 2005 and October 2011, 11 consecutive patients [four men and seven women (mean age 56.7 years)] with CAS and dysfunctional fistulas were treated with insertion of 11 Viabahn stent-grafts. Six stent-grafts were inserted due to residual stenosis after angioplasty and five for fistuloplasty-induced rupture. No patient was lost to follow-up. The technical and clinical success rate was 100 %. Primary access patency rates were 81.8 % [95 % confidence interval (CI) 0.482–0.977] at 6 months and 72.7 % (95 % CI 0.390–0.939) at 12 months. Secondary access patency rates were 90.9 % at 6 months (95 % CI 0.587–0.997). There were no procedure-related complications. Mean follow-up was 543.8 days (range 156–2,282). The use of the Viabahn stent-graft in the management of CAS is technically feasible and, in this small series, showed patency rates that compare favorably with historical data of angioplasty and bare stents.

  9. Thoracic stent grafts with a distal fenestration for the celiac axis

    NARCIS (Netherlands)

    Tielliu, IFJ; Verhoeven, ELG; Zeebregts, CJ; Prins, TR; van den Dungen, JJAM

    2005-01-01

    Descending thoracic aneurysms can be treated with a stent graft provided that there is sufficient proximal and distal aortic neck length above the celiac axis. One of the options for the treatment of thoracic aneurysms with a too short distal neck is described in this report. For this purpose, a

  10. Left subclavian artery revascularization as part of thoracic stent grafting

    NARCIS (Netherlands)

    Saouti, N.; Hindori, V.; Morshuis, W.J.; Heijmen, R.H.

    2015-01-01

    OBJECTIVES: Intentional covering of the left subclavian artery (LSA) as part of thoracic endovascular aortic repair (TEVAR) can cause (posterior) strokes or left arm malperfusion. LSA revascularization can be done as prophylaxis against, or as treatment of, these complications. We report our

  11. Robotic endovascular surgery.

    Science.gov (United States)

    Au, Stephanie; Ko, Koel; Tsang, Josephine; Chan, Yiu Che

    2014-01-01

    The purpose of this review is to compare conventional endovascular procedures and the robotic endovascular approach in aortic aneurysm repair. Despite advantages over open surgery, conventional endovascular surgery has limitations. To develop an alternative, efforts have been focused on robotic endovascular systems. Two of the 3 studies comparing procedure times demonstrated reduced procedure time in the robotic group, by 6 times (p robotic procedures reduced fluoroscopic exposure time by 12 minute (p robotic surgery was reduced up to 10 times (p robotic performance score showed a better performance score in the robotic endovascular group (p = 0.007). These results demonstrate that the robotic technique has multiple advantages over the conventional procedure, including improved catheter stability, a shorter learning curve, reduced procedure time, and better performance in cannulating tortuous vessels. However, robotic endovascular technology may be limited by the cost of the system, the size of the catheter, and the setup time required preoperatively. Further comparative studies between conventional and robotic approaches regarding cost-effectiveness, safety, and performance in cases involving complex anatomy and fenestrated stent grafts are essential. Nevertheless, this revolutionary technology is increasingly popular and may be the next milestone in endovascular surgery.

  12. Improved transjugular intrahepatic portosystemic shunt patency with PTFE-covered stent-grafts: experimental results in swine.

    Science.gov (United States)

    Nishimine, K; Saxon, R R; Kichikawa, K; Mendel-Hartvig, J; Timmermans, H A; Shim, H J; Uchida, B T; Barton, R E; Keller, F S; Rösch, J

    1995-08-01

    To evaluate the ability of stent-grafts made with polytetrafluoroethylene (PTFE) graft material to improve transjugular intrahepatic portosystemic shunt (TIPS) patency. TIPS were created in 13 swine by using PTFE-covered stent-grafts. Uncovered TIPS were placed in 13 other swine. Twenty-one of 26 animals were followed up with portal venography for 3 months or until the shunt became severely stenotic. Five animals without severe stenosis were sacrificed before 3 months because of illness. At 4 weeks after TIPS placement, nine of 13 stent-graft TIPS were patent (late shunt malfunction in selected cases.

  13. Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

    International Nuclear Information System (INIS)

    Saha, Prakash; Hughes, John; Patel, Ashish S.; Donati, Tommaso; Sallam, Morad; Patel, Sanjay D.; Bell, Rachel E.; Katsanos, Konstantinos; Modarai, Bijan; Zayed, Hany A.

    2015-01-01

    PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities

  14. Medium-Term Outcomes Following Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms with an Unfavourable Proximal Neck

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Prakash, E-mail: prakash.2.saha@kcl.ac.uk; Hughes, John, E-mail: johnhughes387@rocketmail.com; Patel, Ashish S., E-mail: ashish.s.patel@kcl.ac.uk; Donati, Tommaso, E-mail: tommaso.donati@gstt.nhs.uk; Sallam, Morad, E-mail: morad.sallam@gstt.nhs.uk; Patel, Sanjay D., E-mail: sanjay.patel@gstt.nhs.uk; Bell, Rachel E. [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Katsanos, Konstantinos, E-mail: katsanos@med.upatras.gr [King’s Health Partners, Department of Interventional Radiology, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom); Modarai, Bijan, E-mail: bijan.modarai@kcl.ac.uk; Zayed, Hany A., E-mail: hany.zayed@gstt.nhs.uk [King’s Health Partners, Department of Vascular Surgery, Guy’s and St. Thomas’ Hospitals, NHS Foundation Trust (United Kingdom)

    2015-08-15

    PurposeThe purpose of this study was to evaluate medium-term outcomes following endovascular repair of abdominal aortic aneurysms (EVAR) with unfavourable neck anatomy using stent grafts with a 36 mm or larger proximal diameter.Materials and MethodsA retrospective review of 27 patients who underwent elective EVAR between 2006 and 2008 using a stent graft with a 36 mm or larger proximal diameter was carried out. All patients had computed tomography angiography (CTA) for procedure planning, and detailed assessment of the aneurysm neck was performed using a three-dimensional CTA workstation. Patients were followed up with CTA at 3 and 12 months and annual duplex thereafter.ResultsThe median aneurysm diameter was 7 cm, and the median aneurysm neck diameter was 31 mm. Cook Zenith stent grafts were used in all patients, with a proximal diameter of 36 mm (n = 25) and 40 mm (n = 2). Primary and assisted primary technical success rates were 74 and 93 %, respectively. The follow-up period ranged from 62 to 84 months, with a median of 72 months. 15 patients died during follow-up. Two patients died from aortic rupture, and the remaining patients died from cardiac disease (n = 4), chest sepsis (n = 6), cancer (n = 2) and renal failure (n = 1). Complications included type I endoleak (n = 5), limb occlusion (n = 2), limb stenosis (n = 2), limb kinking (n = 1), dissection of an artery (n = 1), occlusion of a femorofemoral cross-over graft (n = 1) and poor attachment of a distal limb (n = 1).ConclusionsEVAR using stent grafts in the presence of an unfavourable neck has a high risk of complications. Medium-term survival in this group is low but mainly due to patient co-morbidities.

  15. Surgical treatment and thoracic endovascular aortic repair in type A aortic dissection in a pregnant patient with Marfan syndrome.

    Science.gov (United States)

    Sterner, Doerthe; Probst, Chris; Mellert, Friedrich; Schiller, Wolfgang

    2014-07-01

    We report an acute aortic dissection type Stanford A extending down to both iliac arteries affecting a 32-year-old woman suspected to have Marfan syndrome during week 37 of pregnancy. In a multidisciplinary approach, and emergency Cesarean section was performed followed by an abdominal hysterectomy and a valve-sparing aortic root replacement using a reimplantation technique. The aorta was replaced up to the hemi arch. Because of the high suspicion of visceral ischemia as confirmed ex juvantibus, an endovascular stent graft was implanted. Molecular testing revealed a frameshift mutation and confirmed the diagnosis of Marfan syndrome. Both the patient and her healthy child underwent an uneventful recovery. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Sandwich Technique for Endovascular Repair of Acute Type A Aortic Dissection.

    Science.gov (United States)

    Gao, Feng; Zeng, Qian; Lin, Fangming; Ge, Xiaohu

    2017-10-01

    To describe a new endovascular procedure for acute type A aortic dissection (TAAD) repair. Between 2013 and 2016, 12 patients (average age 54±9.6 years; 10 men) with acute TAAD (mean EURO score 11.4%±3.2%, range 5-17) and unfit for surgery underwent thoracic endovascular aortic repair (TEVAR) with 2 periscope grafts to preserve blood supply to supra-aortic branches plus bypass grafting as needed. If the ascending aorta was dilated to >40 mm, sternotomy was performed to wrap the ascending aorta and reduce its diameter to accommodate the aortic stent-grafts. All patients were successfully treated. Seven patients required bypass grafting, and most of the patients had periscope grafts to the innominate/right common carotid artery and left common carotid artery; only 3 patients had the left subclavian artery preserved. All patients exhibited good hemodynamics and normal pressures after the procedure. The mean procedure time and blood loss were 4.5±1.0 hours and 217±111.5 mL, respectively. Two patients treated emergently died shortly after surgery from multiorgan failure. The average follow-up duration was 17±14.5 months (range 2-42) in the 10 survivors. The remaining patients recovered and none experienced stent-graft thrombosis, stroke, or peripheral artery embolism during follow-up. A procedure that combines sandwich/periscope grafting with TEVAR, wrapping of the aorta, and supra-arch bypass grafting can be used to treat patients with acute TAAD.

  17. Endovascular management of acute bleeding arterioenteric fistulas

    DEFF Research Database (Denmark)

    Leonhardt, H.; Mellander, S.; Snygg, J.

    2008-01-01

    . All had massive persistent bleeding with hypotension despite volume substitution and transfusion by the time of endovascular management. Outcome after treatment of these patients was investigated for major procedure-related complications, recurrence, reintervention, morbidity, and mortality. Mean...... follow-up time was 3 months (range, 1-6 months). All massive bleeding was controlled by occlusive balloon catheters. Four fistulas were successfully sealed with stent-grafts, resulting in a technical success rate of 80%. One patient was circulatory stabilized by endovascular management but needed...

  18. Endovascular management of acute bleeding arterioenteric fistulas

    DEFF Research Database (Denmark)

    Leonhardt, H.; Mellander, S.; Snygg, J.

    2008-01-01

    follow-up time was 3 months (range, 1-6 months). All massive bleeding was controlled by occlusive balloon catheters. Four fistulas were successfully sealed with stent-grafts, resulting in a technical success rate of 80%. One patient was circulatory stabilized by endovascular management but needed...... reintervention. The in-hospital mortality was 20% and the 30-day mortality was 40%. The midterm outcome was poor, due to comorbidities or rebleeding, with a mortality of 80% within 6 months. In conclusion, endovascular repair is an efficient and safe method to stabilize patients with life-threatening bleeding...

  19. ePTFE-covered stent-grafts for revision of obstructed transjugular intrahepatic portosystemic shunt.

    Science.gov (United States)

    Cejna, Manfred; Peck-Radosavljevic, Markus; Thurnher, Siegfried; Schoder, Maria; Rand, Thomas; Angermayr, Bernhard; Lammer, Johannes

    2002-01-01

    To determine whether transjugular intrahepatic portosystemic shunt (TIPS) revisions with the Hemobahn stent-graft or the Viatorr endoprosthesis increase secondary patency rates. Between 1998 and June 1999, Hemobahn endoprostheses (W.L. Gore, Flagstaff, AZ, USA) were used for the revision of obstructed TIPS in seven patients, 51-67 years of age (mean 59 years). From June 1999 to 2000, the Viatorr endoprosthesis (W.L. Gore, Flagstaff, AZ, USA) was used for revision of obstructed TIPS in nine patients, 33-64 years of age (mean 49 years). Follow-up included duplex ultrasound, clinical assessment and venous portography. The technical success rate of TIPS revision with the Hemobahn stent-graft was 100%. The pressure gradient decreased from a mean of 20 mmHg to 10 mmHg. The mean follow-up was 407 days (range 81-868 days). In two patients TIPS occlusion occurred at 62 and 529 days after stent-graft placement, respectively; in another two patients outflow tract stenosis occurred at 275 and 393 days, respectively. The technical success rate of TIPS revision with the Viatorr endoprosthesis was also 100%. The pressure gradient decreased from a mean of 27 mmHg to 11 mmHg. At a mean follow-up of 201 days (range 9-426 days), all Viatorr endoprostheses are still patent without in-graft stenosis, but angioplasty was required in two patients to treat a portosystemic pressure gradient > 15 mmHg. Four of the nine patients in the Viatorr group suffered from new encephalopathy after TIPS revision. The Viatorr endoprosthesis yielded optimal results with 100% in-graft patency rates at follow-up but had a high incidence of new encephalopathy, whereas the use of Hemobahn stent-graft for TIPS revision did not appear to improve the secondary patency rates in our series.

  20. Optimal Covering Material for Stent-Grafts Placed in the Portal Vein in a Canine Model

    International Nuclear Information System (INIS)

    Ishii, Seigo; Sato, Morio; Sonomura, Tetsuo; Yamada, Katsuyuki; Tanihata, Hirohiko; Ishikawa, Hime; Terada, Masaki; Sahara, Shinya; Kawai, Nobuyuki; Kimura, Masashi; Mori, Ichiro

    2005-01-01

    Purpose. We evaluated the suitability of Dacron, polytetrafluoroethylene (PTFE), and small intestinal submucosa (SIS) as a covering material for stent-grafts placed in the portal vein as compared with a bare stent. Methods. Using 24 beagle dogs, either bare stents or stent-grafts covered with Dacron, PTFE, or SIS were placed in the main trunk of the portal vein in 6 animals each. Portography was performed immediately after stent placement, and at 2, 4, and 12 weeks thereafter. Next, the extracted stents or stent-grafts were examined histopathologically. Neointimal thickness adjacent to the stent wire and at the midportion between the stent wires was compared among the groups. Then, the neointimal thickness at the sub- and supragraft sites was compared between each stent-graft group. Serial changes in the histologic features of the thickened neointima were also investigated. Results. No significant difference was noted in the mean stenotic ratio of the portal vein diameter between the bare stent and PTFE groups, whereas it was significantly higher in the Dacron and SIS groups compared with the bare stent group. In neither of the studies on neointimal thickness adjacent to the stent wire and at the midportion between the stent wires were any significant differences noted between the neointimal thickness of the bare stent group and the sum of the neointimal thickness of the PTFE group, whereas the sum of the neointimal thickness of the Dacron and SIS groups was significantly greater than that of the bare stent group at both sites. In the comparison of the supragraft neointimal thickness, the SIS group showed significantly greater thickness than the PTFE group, while the difference between the Dacron and PTFE groups was not significant. In the comparison of the subgraft neointimal thickness, the Dacron and SIS groups showed significantly greater thickness than the PTFE group. Conclusion. The present results indicate that of the three covering materials examined here

  1. Irreversible Electroporation of a Hepatocellular Carcinoma Lesion Adjacent to a Transjugular Intrahepatic Portosystemic Shunt Stent Graft

    Energy Technology Data Exchange (ETDEWEB)

    Niessen, Christoph; Jung, Ernst Michael; Wohlgemuth, Walter A. [Department of Radiology, University Medical Center Regensburg, Regensburg D-93053 (Germany); Trabold, Benedikt [Department of Anaesthesia, University Medical Center Regensburg, Regensburg D-93053 (Germany); Haimerl, Michael; Schreyer, Andreas; Stroszczynski, Christian; Wiggermann, Philipp [Department of Radiology, University Medical Center Regensburg, Regensburg D-93053 (Germany)

    2013-07-01

    We report in a 65-year-old man hepatocellular carcinoma adjacent to a transjugular intrahepatic portosystemic shunt stent-graft which was successfully treated with irreversible electroporation (IRE). IRE is a new non-thermal tissue ablation technique which uses electrical pulses to induce cell necrosis by irreversible membrane poration. IRE proved to be more advantageous in the ablation of perivascular tumor with little injury to the surrounding structures.

  2. Hemolytic effect of deformed intra-arterial stents and stent grafts in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Grimm, Jan; Brunn, Hinrich; Heller, Martin; Mueller-Huelsbeck, Stefan [Klinik fuer Diagnostische Radiologie der Christian-Albrecht-Universitaet (CAU) zu Kiel, A. Heller Strasse 9, 24105 Kiel (Germany)

    2003-06-01

    Our objective was to evaluate the hemolytic effect of stents and stent grafts in an in vitro flow model. The model consisted of silicone tubings. Pulsatile flow was delivered at 1170 ml/min. Diluted packed erythrocytes were used (hematocrit of 33%). The Palmaz, MegaLink stents or Passager, Hemobahn stent grafts were placed in the middle portion of the model; control experiments contained no implant (n=10 each). Concentric stenosis of the implant was achieved by constricting the implant to 25, 50, or 70% (area, n=10 each). Samples were drawn at minute 1, 2, 4, 6, 8, 10, 15, and every 10 min up to 1 h. Hemolytic parameters were evaluated. All implants produced hemolysis, increasing in the course of time. Without deformation (0%) the Hemobahn stent causes less hemolysis compared with the other prostheses. At 25% no significant difference could be shown between all devices. At 50% constriction the Palmaz stent caused more hemolysis than the other grafts, and at 70% stenosis the Palmaz and Hemobahn caused more hemolysis than Passager or Megalink. A hemolytic effect was evaluable, probably due to mechanical stress and sheer forces, induced by turbulences in the proximity of the deformed stent. The stent grafts did not perform better than the stents. Differences in the design of a prosthesis and in the degree of stent deformation seem to have an influence on the hemolysis caused. (orig.)

  3. Stent-Graft Placement with Early Debridement and Antibiotic Treatment for Femoral Pseudoaneurysms in Intravenous Drug Addicts

    International Nuclear Information System (INIS)

    Fu, Qining; Meng, Xiyun; Li, Fenghe; Wang, Xuehu; Cheng, Jun; Huang, Wen; Ren, Wei; Zhao, Yu

    2015-01-01

    PurposeExplore the application of endovascular covered stent-graft (SG) placement in femoral pseudoaneurysms in intravenous drug addicts.Materials and MethodsWe evaluated a consecutive series of pseudoaneurysm in intravenous drug addicts treated with SGs from August 2010 to December 2013.Results15 patients with 16 arterial pseudoaneurysms were enrolled in this study. All were males with a mean age of 36.9 years. Hemorrhage was the most common reason (93.8 %) for seeking medical care, and 3 of these patients were in hemorrhagic shock at admission. All patients received broad-spectrum antibiotics, and debridement and drainage were implemented after SG placement. 7 of the 13 cases which had microbiologic results showed mixed infections, while gram-negative bacteria were the major pathogens. Except for 2 patients, who were lost to follow-up, two new pseudoaneurysms formed due to delayed debridement, and one stent thrombosis occurred, none of the remaining cases had SG infection or developed claudication.ConclusionsSG placement controls massive hemorrhage rapidly, gives enough time for subsequent treatment for pseudoaneurysms due to intravenous drug abuse, and reduces the incidence of postoperative claudication. With appropriate broad-spectrum antibiotics and early debridement, the incidence of SG infection is relatively low. It is an effective alternative especially as temporary bridge measure for critical patients. However, the high cost, uncertain long-term prospects, high demand for medical adherence, and the risk of using the conduits for re-puncture call for a cautious selection of patients. More evidence is required for the application of this treatment

  4. Stent-Graft Placement with Early Debridement and Antibiotic Treatment for Femoral Pseudoaneurysms in Intravenous Drug Addicts

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Qining, E-mail: cqmufqn@163.com; Meng, Xiyun, E-mail: 383274177@qq.com; Li, Fenghe, E-mail: lfh-cqmu@gmail.com; Wang, Xuehu, E-mail: 184037696@qq.co; Cheng, Jun, E-mail: cqdcj@163.com; Huang, Wen, E-mail: dhuangwen@hotmail.com; Ren, Wei, E-mail: renwei9771@yahoo.com.cn; Zhao, Yu, E-mail: zhaoyu-cqmu@126.com [The First Affiliated Hospital of Chongqing Medical University, Department of Vascular Surgery (China)

    2015-06-15

    PurposeExplore the application of endovascular covered stent-graft (SG) placement in femoral pseudoaneurysms in intravenous drug addicts.Materials and MethodsWe evaluated a consecutive series of pseudoaneurysm in intravenous drug addicts treated with SGs from August 2010 to December 2013.Results15 patients with 16 arterial pseudoaneurysms were enrolled in this study. All were males with a mean age of 36.9 years. Hemorrhage was the most common reason (93.8 %) for seeking medical care, and 3 of these patients were in hemorrhagic shock at admission. All patients received broad-spectrum antibiotics, and debridement and drainage were implemented after SG placement. 7 of the 13 cases which had microbiologic results showed mixed infections, while gram-negative bacteria were the major pathogens. Except for 2 patients, who were lost to follow-up, two new pseudoaneurysms formed due to delayed debridement, and one stent thrombosis occurred, none of the remaining cases had SG infection or developed claudication.ConclusionsSG placement controls massive hemorrhage rapidly, gives enough time for subsequent treatment for pseudoaneurysms due to intravenous drug abuse, and reduces the incidence of postoperative claudication. With appropriate broad-spectrum antibiotics and early debridement, the incidence of SG infection is relatively low. It is an effective alternative especially as temporary bridge measure for critical patients. However, the high cost, uncertain long-term prospects, high demand for medical adherence, and the risk of using the conduits for re-puncture call for a cautious selection of patients. More evidence is required for the application of this treatment.

  5. Endovascular treatment of a bleeding secondary aorto-enteric fistula. A case report with 1-year follow-up.

    Science.gov (United States)

    Brountzos, Elias N; Vasdekis, Spyros; Kostopanagiotou, Georgia; Danias, Nikolaos; Alexopoulou, Efthymia; Petropoulou, Konstantina; Gouliamos, Athanasios; Perros, Georgios

    2007-01-01

    We report a patient with life-threatening gastrointestinal bleeding caused by a secondary aorto-enteric fistula. Because the patient had several comorbid conditions, we succesfully stopped the bleeding by endovascular placement of a bifurcated aortic stent-graft. The patient developed periaortic infection 4 months later, but he was managed with antibiotics. The patient is well 1 year after the procedure.

  6. [Endovascular repair of iliocaval arteriovenous fistula complicating lumbar disc surgery].

    Science.gov (United States)

    Ben Jemaa, H; Maalej, A; Lazzez, K; Jemal, H; Karray, S; Ben Mahfoudh, K

    2016-05-01

    Vascular complications of lumbar disc surgery are rare. Few cases have been reported. Arteriovenous fistulas are the most common. They are due to anatomical relationships between the last lumbar vertebrae, the corresponding discs, and the iliac vessels; degenerative lesions of the intervertebral discs facilitate instrumental vessel perforation, and operative difficulty. Computed tomography is particularly accurate for making the diagnosis. Treatment strategies consist in surgery or endovascular management. Percutaneous endovascular treatment using a stent-graft is a reasonable option for treating arteriovenous fistula. We describe the case of a 50-year-old patient who developed an iliocaval arteriovenous fistula following lumbar disc hernia surgery. The lesion was excluded by a stent-graft. The postoperative period was uneventful. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. Mechanical properties of various z-stent designs: an endovascular stent-grafting perspective.

    Science.gov (United States)

    Bashar, Abul Hasan Muhammad; Kazui, Teruhisa; Washiyama, Naoki; Terada, Hitoshi; Yamashita, Katsushi; Haque, Mohammad E

    2003-08-01

    To comparatively assess the mechani-cal behavior of various clinically relevant Z-stent designs. A total of 16 Z-stents of original, biliary, spiral, and double-skirted designs (n=4 for each) were constructed using similar specifications for all. Stents were then evaluated for stiffness, snap opening force (SOF), flexibility, and displacement force using a novel tensiometer. Differences among the stents were determined using statistical methods. Stents explanted from dog aorta after a mean follow-up of 13 months were examined under a scanning electron microscope for surface defects. Forces required for about 50% reduction in diameter were 1.88 +/- 0.16 N, 3.81 +/- 0.21 N, 2.76 +/- 0.22 N, and 3.35 +/- 0.19 N for original, biliary, spiral, and skirted designs, respectively. Differences among the four designs were statistically significant at almost all points of measurement (P designs showed higher SOF values in the early measurements. Stents explanted from dog aorta after a mean duration of 13 months showed no obvious corrosion or breakage in the wire struts. Significant differences exist among the various Z-stent designs in terms of their mechanical properties. Understanding them should help to select the appropriate stent for a given lesion. 316L stainless steel shows a favorable long-term tissue interaction.

  8. Applicability and midterm results of branch cuff closure with vascular plug in branched endovascular repair for thoracoabdominal aortic aneurysms.

    Science.gov (United States)

    Hongku, Kiattisak; Resch, Timothy; Sonesson, Björn; Kristmundsson, Thorarinn; Dias, Nuno V

    2017-08-01

    This study assessed the applicability and outcomes of the closure of unused cuffs in branched endovascular aneurysm repair (b-EVAR) of thoracoabdominal aortic aneurysm. We reviewed b-EVAR procedures at a tertiary referral center to identify patients who underwent incomplete branching and needed closure of the unused branch cuffs. An electronic database and intraoperative and follow-up imaging studies were reviewed to assess technical applicability and outcomes. Between January 2007 and December 2015, 17 patients underwent incomplete branching during b-EVAR. The unused branch cuff in one patient occluded spontaneously after b-EVAR and was excluded from this analysis. The remaining 16 patients underwent 11 elective and five emergency repairs. Amplatzer Vascular Plugs (St. Jude Medical, Plymouth, Minn) were used to successfully close 17 branches: 8 targeting preoperatively occluded target vessels, 3 optional branches where fenestrations were used instead, 5 after failures of catheterization or stent bridging to target vessels, and 1 renal branch of an atrophic kidney. Four branch cuffs were extended with a peripheral covered stent before plug deployment. Sixteen branch cuffs were closed intraoperatively, and the remaining cuff was closed percutaneously at a later occasion. Perioperative death occurred in two patients. Median follow-up duration was 19 months (interquartile range, 11-30 months). There was no endoleak or reintervention related to the plugged cuffs. Two late deaths occurred not related to the aneurysm. Two patients required reinterventions for type III endoleaks with interval sac expansions caused by aortic stent graft component separation in tortuous thoracic segments not related to the occluded cuffs. Closure of the branch cuff of multibranched stent graft with Amplatzer Vascular Plug is feasible and effective. It was not associated with adverse aneurysm outcomes, and it is very useful especially when using an off-the-shelf device in the acute setting

  9. Extrahepatic Pseudoaneurysms and Ruptures of the Hepatic Artery in Liver Transplant Recipients: Endovascular Management and a New Iatrogenic Etiology

    Energy Technology Data Exchange (ETDEWEB)

    Saad, Wael E. A., E-mail: wspikes@yahoo.com; Dasgupta, Niloy; Lippert, Allison J.; Turba, Ulku C.; Davies, Mark G. [University of Virginia Health System, Division of Vascular Interventional Radiology, Department of Radiology (United States); Kumer, Sean [University of Virginia Health System, Division of Solid Organ Transplantation, Department of Surgery (United States); Gardenier, Jason C.; Sabri, Saher S.; Park, Auh-Whan [University of Virginia Health System, Division of Vascular Interventional Radiology, Department of Radiology (United States); Waldman, David L. [University of Rochester Medical Center, Department of Imaging Sciences (United States); Schmitt, Timothy [University of Virginia Health System, Division of Solid Organ Transplantation, Department of Surgery (United States); Matsumoto, Alan H.; Angle, John F. [University of Virginia Health System, Division of Vascular Interventional Radiology, Department of Radiology (United States)

    2013-02-15

    To characterize extrahepatic pseudoaneurysm regarding incidence and etiology and determine the effectiveness of endovascular management. A retrospective audit of 1,857 liver transplants in two institutions was performed (1996-2009). Recipients' demographics, clinical presentation, transplant type, biliary anastomosis, and presence of biliary endoprostheses were noted. Pseudoaneurysms were classified into iatrogenic (associated with biliary endoprosthesis or angioplasty) or spontaneous extrahepatic pseudoaneurysms. Spontaneous and iatrogenic pseudoaneurysms were compared for time from transplant, presenting symptoms, location in the arterial anatomy, and 3-month graft survival. Arterial patency and 6-month graft survival were calculated. Twenty pseudoaneurysms were found (1.1 %, 20/1,857): 9 (0.5 % of transplants, 9/1,857) were spontaneous and 11 (0.6 % of transplants, 11/1,857) were 'iatrogenic' (due to minimally invasive procedures: 4 angioplasty and 7 biliary endoprostheses). Sixty percent (12/20) underwent endovascular management (4 coil embolization and 8 stent-grafts). Technical success was 83 % (10/12) with a mean arterial patency of 70 % (follow-up mean, 4.9; range, 0-18 months). The 1-, 3-, and 6-month graft survival was 70, 40, and 35 %, respectively. Due to minimally invasive procedures, posttransplant extrahepatic pseudoaneurysms are no longer an exclusive complication of the transplant surgery itself. Endovascular management is effective to stabilize patients but has not improved historic postsurgical graft survival.

  10. Percutaneous Endoluminal Stent-Graft Repair of an Old Traumatic Femoral Arteriovenous Fistula

    International Nuclear Information System (INIS)

    Uflacker, Renan; Elliott, Bruce M.

    1996-01-01

    A stent-graft was custom made to close a high-flow traumatic arteriovenous fistula of the left superficial femoral artery, present for 30 years, in a 60-year-old man with congestive heart failure and ischemic ulceration in the left foot. A balloon expandable Palmaz stent (P394; 2.5 mm x 3.9 cm) was covered with a polytetrafluoroethylene (PTFE) graft and was inserted percutaneously through an 11 Fr vascular sheath. Follow-up Doppler ultrasound at 6 months demonstrated occlusion of the arteriovenous fistula, patency of the artery, and luminal integrity of the artery and vein

  11. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  12. Mid-Term Outcomes of Endovascular Treatment for TASC-II D Femoropopliteal Occlusive Disease with Critical Limb Ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Torres-Blanco, Álvaro, E-mail: atorres658@yahoo.es; Edo-Fleta, Gemma; Gómez-Palonés, Francisco; Molina-Nácher, Vicente; Ortiz-Monzón, Eduardo [Hospital Universitario Dr. Peset, Department of Angiology, Endovascular and Vascular Surgery (Spain)

    2016-03-15

    PurposeThe purpose of the study was to assess the safety and midterm effectiveness of endovascular treatment in Trans-Atlantic Inter-Society Consensus II (TASC-II) D femoropopliteal occlusions in patients with critical limb ischemia (CLI).MethodsPatients with CLI who underwent endovascular treatment for TASC-D de novo femoropopliteal occlusive disease between September 2008 and December 2013 were selected. Data included anatomic features, pre- and postprocedure ankle-brachial index, duplex ultrasound, and periprocedural complications. Sustained clinical improvement, limb salvage rate, freedom from target lesion revascularization (TLR), and freedom from target extremity revascularization (TER) were assessed by Kaplan–Meier estimation and predictors of restenosis/occlusion with Cox analysis.ResultsThirty-two patients underwent treatment of 35 TASC-D occlusions. Mean age was 76 ± 9. Mean lesion length was 23 ± 5 cm. Twenty-eight limbs (80 %) presented tissue loss. Seventeen limbs underwent treatment by stent, 13 by stent-graft, and 5 by angioplasty. Mean follow-up was 29 ± 20 months. Seven patients required major amputation and six patients died during follow-up. Eighteen endovascular and three surgical TLR procedures were performed due to restenosis or occlusion. Estimated freedom from TLR and TER rates at 2 years were 41 and 76 %, whereas estimated primary and secondary patency rates were 41 and 79 %, respectively.ConclusionsEndovascular treatment for TASC II D lesions is safe and offers satisfying outcomes. This patient subset would benefit from a minimally invasive approach. Follow-up is advisable due to a high rate of restenosis. Further follow-up is necessary to know the long-term efficacy of these procedures.

  13. Blood flow velocity prediction in aorto-iliac stent grafts using computational fluid dynamics and Taguchi method.

    Science.gov (United States)

    Chong, Albert Y; Doyle, Barry J; Jansen, Shirley; Ponosh, Stefan; Cisonni, Julien; Sun, Zhonghua

    2017-05-01

    Covered Endovascular Reconstruction of Aortic Bifurcation (CERAB) is a new technique to treat extensive aortoiliac occlusive disease with covered expandable stent grafts to rebuild the aortoiliac bifurcation. Post stenting Doppler ultrasound (DUS) measurement of maximum peak systolic velocity (PSV max ) in the stented segment is widely used to determine patency and for follow up surveillance due to the portability, affordability and ease of use. Anecdotally, changes in hemodynamics created by CERAB can lead to falsely high PSV max requiring CT angiography (CTA) for further assessment. Therefore, the importance of DUS would be enhanced with a proposed PSV max prediction tool to ascertain whether PSV max falls within the acceptable range of prediction. We have developed a prediction tool based on idealized models of aortoiliac bifurcations with various infra-renal PSV (PSV in ), iliac to aortic area ratios (R) and aortoiliac bifurcation angles (α). Taguchi method with orthogonal arrays (OA) was utilized to minimize the number of Computational Fluid Dynamics (CFD) simulations performed under physiologically realistic conditions. Analysis of Variance (ANOVA) and Multiple Linear Regression (MLR) analyses were performed to assess Goodness of fit and to predict PSV max. PSV in and R were found to contribute 94.06% and 3.36% respectively to PSV max . The Goodness of fit based on adjusted R 2 improved from 99.1% to 99.9% based on linear and exponential functions. The PSV max predictor based on the exponential model was evaluated with sixteen patient specific cases with a mean prediction error of 9.9% and standard deviation of 6.4%. Eleven out of sixteen cases (69%) in our current retrospective studies would have avoided CTA if the proposed predictor was used to screen out DUS measured PSV max with prediction error greater than 15%. The predictor therefore has the potential to be used as a clinical tool to detect PSV max more accurately post aortoiliac stenting and might

  14. An in Vitro Twist Fatigue Test of Fabric Stent-Grafts Supported by Z-Stents vs. Ringed Stents

    Directory of Open Access Journals (Sweden)

    Jing Lin

    2016-02-01

    Full Text Available Whereas buckling can cause type III endoleaks, long-term twisting of a stent-graft was investigated here as a mechanism leading to type V endoleak or endotension. Two experimental device designs supported with Z-stents having strut angles of 35° or 45° were compared to a ringed control under accelerated twisting. Damage to each device was assessed and compared after different durations of twisting, with focus on damage that may allow leakage. Stent-grafts with 35° Z-stents had the most severe distortion and damage to the graft fabric. The 45° Z-stents caused less fabric damage. However, consistent stretching was still seen around the holes for sutures, which attach the stents to the graft fabric. Larger holes may become channels for fluid percolation through the wall. The ringed stent-graft had the least damage observed. Stent apexes with sharp angles appear to be responsible for major damage to the fabrics. Device manufacturers should consider stent apex angle when designing stent-grafts, and ensure their devices are resistant to twisting.

  15. Bronchobiliary Fistula Treated by Self-expanding ePTFE-Covered Nitinol Stent-Graft

    International Nuclear Information System (INIS)

    Gandini, Roberto; Konda, Daniel; Tisone, Giuseppe; Pipitone, Vincenzo; Anselmo, Alessandro; Simonetti, Giovanni

    2005-01-01

    A 71-year-old man, who had undergone right hepatectomy extended to the caudate lobe with terminolateral Roux-en-Y left hepatojejunostomy for a Klatskin tumor, developed bilioptysis 3 weeks postoperatively due to bronchobiliary fistula. Percutaneous transhepatic cholangiography revealed a non-dilated biliary system with contrast medium extravasation to the right subphrenic space through a resected anomalous right posterior segmental duct. After initial unsuccessful internal-external biliary drainage, the fistula was sealed with a VIATORR covered self-expanding nitinol stent-graft placed with its distal uncovered region in the hepatojejunal anastomosis and the proximal ePTFE-lined region in the left hepatic duct. A 10-month follow-up revealed no recurrence of bilioptysis and confirmed the complete exclusion of the bronchobiliary fistula

  16. [Classification and treatment of endoleaks after endovascular treatment of abdominal aortic aneurysms].

    Science.gov (United States)

    Pitton, M B; Schmiedt, W; Neufang, A; Düber, C; Thelen, M

    2005-01-01

    This article describes the classification of endoleaks after endovascular treatment of abdominal aortic aneurysms, thereby summarizing the most important problems of this endovascular technique. The correct classification of endoleaks is a prerequisite for interdisciplinary discussion. It is indispensable for professional reporting of the pathological findings and for the decision making as to the adequate treatment of endoleaks. Irrespective of the types of stent graft and property of the material, five endoleak types are defined in the literature: leakage at the anchor sites (type I); leakage due to collateral arteries (type II); defective stent grafts (type III); leakage due to porosity of the graft material (type IV); and endotension (type V). The causes of endoleaks are discussed and treatment options are reviewed for the diverse pathologic findings.

  17. Classification and treatment of endoleaks after endovascular treatment of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Pitton, M.B.; Thelen, M.; Schmiedt, W.; Neufang, A.; Dueber, C.

    2005-01-01

    This article describes the classification of endoleaks after endovascular treatment of abdominal aortic aneurysms, thereby summarizing the most important problems of this endovascular technique. The correct classification of endoleaks is a prerequisite for interdisciplinary discussion. It is indispensable for professional reporting of the pathological findings and for the decision making as to the adequate treatment of endoleaks. Irrespective of the types of stent graft and property of the material, five endoleak types are defined in the literature: leakage at the anchor sites (type I); leakage due to collateral arteries (type II); defective stent grafts (type III); leakage due to porosity of the graft material (type IV); and endotension (type V). The causes of endoleaks are discussed and treatment options are reviewed for the diverse pathologic findings. (orig.)

  18. Endovascular repair of postoperative vascular graft related complications after aorto-iliac surgery

    DEFF Research Database (Denmark)

    Duvnjak, Stevo; Andersen, P E; Larsen, K E

    2014-01-01

    with anastomotic pseudoaneurysms without leak, of which three had proximal anastomotic pseudoaneurysms and one had distal iliac anastomotic pseudoaneurysm. Implanted stent graft were Endurant (Medtronic) bifurcated endoprostheses in three patients and Excluder (Gore) prosthesis in a two cases. Tubular Medtronic...... endoprosthesis was implanted in one case and in two cases aortic cuff was used. Fluency periphery stent grafts were used in four cases. There was a 100% technical success. Intervention related early mortality was 8%. One patient with pseudoaneurysm died 28 months after endovascular treatment because of cardiac......-36 months) in the other 9 patients. There were no complications like endoleaks or limb occlusions. CONCLUSION: Endovascular treatment of vascular graft related postsurgical complications is a valuable therapeutic option followed by lower mortality and morbidity rates compared with re-operation. Short...

  19. Endovascular repair of abdominal aortic aneurysm with severely angulated neck and tortuous artery access: case report and literature review.

    Science.gov (United States)

    Zeng, Qinglong; Huang, Lianjun; Huang, Xiaoyong; Peng, Mingliang

    2015-03-08

    Endovascular aneurysm repair has revolutionized the therapeutic strategy for abdominal aortic aneurysm. However, hostile proximal aneurysmal neck and tortuosity of access vessels remain challenges in selecting optimal stent-grafts in abdominal aortic aneurysms with difficult anatomy. A 65-year-old woman complained of intermittent abdominal pain for one week. Computed tomography angiogram demonstrated a tortuous infrarenal abdominal aortic aneurysm with a tapered neck and a 136° of infrarenal angulation. Aneurysmal dilatation and severe calcification of bilateral iliac arteries and tortuous aortoiliac access were also showed. Endovascular approach using Endurant stent-graft was attempted at an outside hospital, but failed because of the significant tortuosity of the abdominal aorta and iliac arteries. Since the patient refused to have open aneurysm repair, he was transferred to our hospital for further evaluation and possible EVAR with a different approach. EVAR was performed successfully using Gore Excluder stent-grafts (W.L. Gore & Associates, Flagstaff, AZ, USA). During the procedure, cannulation of the contralateral limb was unable to be achieved because of the tortuous aortoiliac course. Therefore, a snare was inserted from right radial artery, through the contralateral gate, to grasp the wire from left femoral artery. Two iliac stent-grafts were sequentially deployed with the lower end distal to the opening of the left internal iliac artery. Angiography confirmed complete sealing of the aneurysm with patency of bilateral renal arteries and external iliac arteries. The postoperative courses were uneventful and follow-up computed tomography angiogram at 6 months demonstrated patent bilateral femoral and renal arteries without endoleaks or stent migration. Although endovascular repair of aortic aneurysm with hostile neck and tortuous access is rather challenging, choosing flexible stent-grafts and suitable techniques is able to achieve an encouraging outcome.

  20. Concepts to optimize stent-grafting of abdominal aortic aneurysms based on results of experimental studies

    International Nuclear Information System (INIS)

    Chavan, A.; Kirchhoff, T.; Baus, S.; Galanski, M.; Pichlmaier, M.

    2001-01-01

    Purpose. In the endoluminal therapy of abdominal aortic aneurysms, a short proximal aneurysm neck, endoleaks and the large size and stiffness of the introducer systems are responsible for many of the complications and sub-optimal outcomes. The purpose of the present review article is to to suggest strategies to minimize these complications based on the results of experimental studies in animals. Material and methods. After implanting various types of stents across the renal artery origins, the functional and morphological changes in the kidneys and renal vessels were studied by various authors. In order to prevent progressive widening of the proximal aneurysmal neck and graft dislocation, Sonesson et al. performed a laparoscopic banding around the proximal neck in pigs. To study the effects of endoleaks, Marty, Schurink and Pitton carried out pressure measurements in experimental aneurysms with and without endoleaks. Sakaguchi and Pavcnik developed the 'Twin-tube endografts' (TTEG) and the 'Bifurcated drum occluder endografts' (BDOEG) and tested them in dogs. Results. Up to 3 months after suprarenal stent placement, Chavan et al. detected no significant fall in the mean inulin clearance in sheep (140±46 ml/min before, 137±58 ml/min after). Nasim et al. and Malina et al. reported similar observations with respect to renal function. Suprarenal fixation may result in isolated thrombotic occlusions of the renal arteries and microinfarcts in the kidneys. Mean aortic diameters at the level of banding were significantly smaller in the animals with aortic banding as opposed to those in the control group without banding (8 mm vs 11 mm, p=0.004). The banding caused a secure proximal fixation of the stent-graft. Persistent endoleaks resulted in significantly higher intraaneurysmal pressures. Although the TTEG and the BDOEG stent-grafts required smaller sheaths, occlusions were observed in 8% (TTEG) and 60% (BDOEG) of the graft limbs. (orig.) [de

  1. Emergency Endovascular “Bridge” Treatment for Iliac-Enteric Fistula

    International Nuclear Information System (INIS)

    Franchin, Marco; Tozzi, Matteo; Piffaretti, Gabriele; Carrafiello, Gianpaolo; Castelli, Patrizio

    2011-01-01

    Aortic aneurysm has been reported to be the dominant cause of primary iliac-enteric fistula (IEF) in >70% of cases [1]; other less common causes of primary IEF include peptic ulcer, primary aortitis, pancreatic pseudocyst, or neoplastic erosion into an adjacent artery [2, 3]. We describe an unusual case of IEF managed with a staged approach using an endovascular stent-graft as a “bridge” in the emergency setting to optimize the next elective definitive excision of the lesion.

  2. Successful endovascular treatment of a hemodialysis graft pseudoaneurysm by covered stent and direct percutaneous thrombin injection.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2011-07-25

    Vascular access for hemodialysis remains a challenge for nephrologists, vascular surgeons, and interventional radiologists alike. Arteriovenous fistula and synthetic grafts remain the access of choice for long-term hemodialysis; however, they are subject to complications from infection and repeated needle cannulation. Pseudoaneurysms are an increasingly recognized adverse event. At present, there are many minimally invasive methods to repair these wall defects. We present a graft pseudoaneurysm, which required a combination of endovascular stent graft placement and percutaneous thrombin injection for successful occlusion.

  3. Inferior mesenteric artery as outflow vessel in endoleaks after abdominal aortic stent-graft implantation: 36-month follow-up CT study

    Energy Technology Data Exchange (ETDEWEB)

    Dorffner, R.; Mostbeck, G. [Dept. of Radiology, Hospital of the Brothers of St. John, Eisenstadt (Austria); Schoder, M.; Thurnher, S.; Lammer, J. [Dept. of Angiography and Interventional Radiology, Univ. of Vienna (Austria); Hoelzenbein, T. [Dept. of Vascular Surgery, Univ. of Vienna (Austria)

    2001-11-01

    The aim of this study was to determine the role of the inferior mesenteric artery (IMA) as an outflow vessel in endoleaks after abdominal aortic stent-graft implantation. Forty consecutive patients in whom abdominal aortic aneurysms (AAA) had been treated with stent-graft implantation were evaluated retrospectively. Spiral-CT examinations and angiographies up to 36 months after implantation were analyzed. In 29 (73%) of the 40 patients the IMA was perfused prior to implantation. In 5 (17%) of these 29 cases, the artery remained perfused after stent-graft insertion. In all 5 cases, endoleaks were detected; however, in none of these cases was the IMA the sole cause. In 3 of these 5 cases, angiography showed antegrade flow in the IMA. Implantation of extension stent grafts caused thrombosis of the aneurysmal sac and the IMA. There were no secondary endoleaks caused by the IMA at the 36-month follow-up examinations. The majority of IMAs which are patent prior to intervention occlude after successful stent-graft insertion. In cases with leaks and angiographically proven antegrade flow in the IMA, implantation of extension stent grafts is a therapeutic alternative to embolization. In this study, the IMA was not responsible for secondary endoleaks. (orig.)

  4. Inferior mesenteric artery as outflow vessel in endoleaks after abdominal aortic stent-graft implantation: 36-month follow-up CT study

    International Nuclear Information System (INIS)

    Dorffner, R.; Mostbeck, G.; Schoder, M.; Thurnher, S.; Lammer, J.; Hoelzenbein, T.

    2001-01-01

    The aim of this study was to determine the role of the inferior mesenteric artery (IMA) as an outflow vessel in endoleaks after abdominal aortic stent-graft implantation. Forty consecutive patients in whom abdominal aortic aneurysms (AAA) had been treated with stent-graft implantation were evaluated retrospectively. Spiral-CT examinations and angiographies up to 36 months after implantation were analyzed. In 29 (73%) of the 40 patients the IMA was perfused prior to implantation. In 5 (17%) of these 29 cases, the artery remained perfused after stent-graft insertion. In all 5 cases, endoleaks were detected; however, in none of these cases was the IMA the sole cause. In 3 of these 5 cases, angiography showed antegrade flow in the IMA. Implantation of extension stent grafts caused thrombosis of the aneurysmal sac and the IMA. There were no secondary endoleaks caused by the IMA at the 36-month follow-up examinations. The majority of IMAs which are patent prior to intervention occlude after successful stent-graft insertion. In cases with leaks and angiographically proven antegrade flow in the IMA, implantation of extension stent grafts is a therapeutic alternative to embolization. In this study, the IMA was not responsible for secondary endoleaks. (orig.)

  5. Emergency Endovascular Treatment of Abdominal Aortic Aneurysms: Feasibility and Results

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Fontana, Federico; Caronno, Roberto; Castelli, Patrizio; Cuffari, Salvatore; Fugazzola, Carlo

    2006-01-01

    Purpose. To assess the feasibility and effectiveness of emergency endovascular treatment of abdominal aortic aneurysms (AAAs). Methods. During 36 months we treated, on an emergency basis, 30 AAAs with endovascular exclusion. In 21 hemodynamically stable patients preoperative CT angiography (CTA) was performed to confirm the diagnosis and to plan the treatment; 9 patients with hemorrhagic shock were evaluated with angiography performed in the operating room. Twenty-two Excluder (Gore) and 8 Zenith (Cook) stent-grafts (25 bifurcated and 5 aorto-uni-iliac) were used. The follow-up was performed by CTA at 1, 3, 6, and 12 months. Results. Technical success was achieved in 100% of cases with a 10% mortality rate. The total complication rate was 23% (5 increases in serum creatinine level and 2 wound infections). During the follow-up, performed in 27 patients (1-36 months, mean 15.2 months), 4 secondary endoleaks (15%) (3 type II, 2 spontaneously thrombosed and 1 under observation, and 1 type III treated by iliac extender insertion) and 1 iliac leg occlusion (treated with femoro-femoral bypass) occurred. We observed a shrinkage of the aneurysmal sac in 8 of 27 cases and stability in 19 of 27 cases; we did not observe any endotension. Conclusions. Endovascular repair is a good option for emergency treatment of AAAs. The team's experience allows correct planning of the procedure in emergency situations also, with technical results comparable with elective repair. In our experience the bifurcated stent-graft is the device of choice in patients with suitable anatomy because the procedure is less time-consuming than aorto-uni-iliac stent-grafting with surgical crossover, allowing faster aneurysm exclusion. However, further studies are required to demonstrate the long-term efficacy of endovascular repair compared with surgical treatment

  6. Results of Stent Graft Placement to Treat Cephalic Arch Stenosis in Hemodialysis Patients with Dysfunctional Brachiocephalic Arteriovenous Fistulas.

    Science.gov (United States)

    Jones, Robert G; Willis, Andrew P; Tullett, Karen; Riley, Peter L

    2017-10-01

    To determine effectiveness of the VIABAHN (W.L. Gore & Associates, Flagstaff, Arizona) stent graft to treat cephalic arch stenosis in patients with dysfunctional brachiocephalic arteriovenous fistulas after inadequate venoplasty response. Between 2012 and 2015, patients with failed venoplasty of symptomatic cephalic arch stenosis received a VIABAHN stent graft. Follow-up venography was performed at approximately 3, 6, and 12 months. Data were retrospectively analyzed with patency estimated using Kaplan-Meier and log-rank methodology. There were 39 patients included. Technical and clinical success was 100%. Primary target lesion patency was 85% (95% confidence interval [CI], 69%-93%), 67% (95% CI, 50%-80%), and 42% (95% CI, 25%-57%) at 3, 6, and 12 months. There was no significant difference in patency with regard to sex or age (P = .8 and P = .6, respectively). Primary assisted patency was 95% (95% CI, 82%-99%) at 3, 6, and 12 months. Access circuit primary patency was 85% (95% CI, 69%-93%), 67% (95% CI, 50%-80%), and 42% (95% CI, 25%-57%) at 3, 6, and 12 months. There was no significant difference in patency between patients with the stent graft as the first treatment episode in the cephalic arch and those that had previous intervention at this site (P = .98). There were 48 repeat venoplasty procedures performed in the cephalic arch to maintain patency, including 7 repeat VIABAHN insertions. No complications were encountered. The VIABAHN stent graft is a safe, effective, and durable device for treating cephalic arch stenosis when venoplasty fails. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.

  7. Femoro-Supragenicular Popliteal Bypass with a Bridging Stent Graft in a Diffusely Diseased Distal Target Popliteal Artery: Alternative to Below-Knee Popliteal Polytetrafluoroethylene Bypass

    Directory of Open Access Journals (Sweden)

    Joung Hun Byun

    2017-10-01

    Full Text Available Background: Lesions in distal target arteries hinder surgical bypass procedures in patients with peripheral arterial occlusive disease. Methods: Between April 2012 and October 2015, 16 patients (18 limbs with lifestyle- limiting claudication (n=12 or chronic critical limb ischemia (n=6 underwent femoral–above-knee (AK polytetrafluoroethylene (PTFE bypass grafts with a bridging stent graft placement between the distal target popliteal artery and the PTFE graft. Ring-supported PTFE grafts were used in all patients with no available vein for graft material. Follow-up evaluations assessed clinical symptoms, the ankle-brachial index, ultrasonographic imaging and/or computed tomography angiography, the primary patency rate, and complications. Results: All procedures were successful. The mean follow-up was 12.6 months (range, 11 to 14 months, and there were no major complications. The median baseline ankle-brachial index of 0.4 (range, 0.2 to 0.55 significantly increased to 0.8 (range, 0.5 to 1.0 at 12 months (p<0.01. The primary patency rate at 12 months was 83.3%. The presenting symptoms resolved within 2 weeks. Conclusion: In AK bypasses with a diffusely diseased distal target popliteal artery or when below-knee (BK bypass surgery is impossible, this procedure could be clinically effective and safe when used as an alternative to femoral-BK bypass surgery.

  8. Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Koike, Yuya, E-mail: r06118@hotmail.co.jp; Nishimura, Jun-ichi, E-mail: jun-ichi-n@nifty.com; Hase, Soichiro, E-mail: haseman@hotmail.co.jp; Yamasaki, Motoshige, E-mail: genyamasaki@gmail.com [Kawasaki Saiwai Hospital, Department of Interventional Radiology (Japan)

    2015-04-15

    PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasation of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.

  9. Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

    International Nuclear Information System (INIS)

    Koike, Yuya; Nishimura, Jun-ichi; Hase, Soichiro; Yamasaki, Motoshige

    2015-01-01

    PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasation of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients

  10. Endovascular Management of Right Subclavian Artery Pseudoaneurysm due to War Injury in Adolescent Patient

    Directory of Open Access Journals (Sweden)

    Onur Saydam

    2017-01-01

    Full Text Available Today there is a widespread use of endovascular treatment (EVT for traumatic vascular injuries in adults, but there is lack of evidence of its use in adolescent patients with vascular injuries. With this case, we present successful EVT of 14-year-old adolescent with a right subclavian artery pseudoaneurysm (SAP due to war injury. SAP was successfully excluded with deployment of 6×50 mm flexible, self-expanding covered nitinol stent graft (The GORE® VIABAHN® Endoprosthesis (W.L. Gore & Associates, Flagstaff, AZ. Patient was discharged from hospital 2 days after the procedure with dual antiplatelet therapy (clopidogrel and aspirin. 3 months after discharge control DUS showed patent stent graft without any residual lesions. As a result, EVT is an alternative approach to treatment of SAP. It is safe, effective, and less invasive therapy for SAP in adults as well as in adolescents. We aim to contribute to the literature with this first case report.

  11. Endovascular Management of Right Subclavian Artery Pseudoaneurysm due to War Injury in Adolescent Patient.

    Science.gov (United States)

    Saydam, Onur; Şerefli, Deniz; Atay, Mehmet; Sert, Cengiz

    2017-01-01

    Today there is a widespread use of endovascular treatment (EVT) for traumatic vascular injuries in adults, but there is lack of evidence of its use in adolescent patients with vascular injuries. With this case, we present successful EVT of 14-year-old adolescent with a right subclavian artery pseudoaneurysm (SAP) due to war injury. SAP was successfully excluded with deployment of 6 × 50 mm flexible, self-expanding covered nitinol stent graft (The GORE® VIABAHN® Endoprosthesis (W.L. Gore & Associates, Flagstaff, AZ)). Patient was discharged from hospital 2 days after the procedure with dual antiplatelet therapy (clopidogrel and aspirin). 3 months after discharge control DUS showed patent stent graft without any residual lesions. As a result, EVT is an alternative approach to treatment of SAP. It is safe, effective, and less invasive therapy for SAP in adults as well as in adolescents. We aim to contribute to the literature with this first case report.

  12. Catheter-based tricuspid valve replacement: first experimental data of a newly designed bileaflet stent graft prosthesis.

    Science.gov (United States)

    Lausberg, Henning F; Gryszkiewicz, Rafal; Kuetting, Maximilian; Baumgaertner, Moritz; Centola, Marcos; Wendel, Hans-Peter; Nowak-Machen, Martina; Schibilsky, David; Kruger, Tobias; Schlensak, Christian

    2017-07-01

    Moderate or severe degree tricuspid valve regurgitation (TVR) is associated with high rates of morbidity and mortality. Surgical correction as the only therapeutic option offers unsatisfactory results. Recently, several interventional procedures have been introduced clinically in a limited cohort. We present our initial experiments with an innovative interventional valved stent graft for treatment of TVR. A newly designed porcine pericardium-covered nitinol stent graft with a lateral bicuspid valve was adapted to size in a cadaver study. After haemodynamic testing in an ex vivo perfusion setup, vascular access, valve delivery and function were investigated in an ovine animal model ( n  = 7). The device was implanted successfully in all animals. Vascular access was established surgically via the femoral vein without any vascular complications. Angiography demonstrated the correct position of the device with proper sealing of both venae cavae in 6 animals. In 1 extremely large animal, the position of the device was considered too cranial but still acceptable. Correct valve function was verified in all animals by both angiography and echocardiography. There were no persistent arrhythmias other than during valve implant. All animals survived the implant procedure and were sacrificed electively. This study demonstrated that this new valved stent graft could be delivered safely with correct positioning and valve function in this ovine model. Further long-term studies in animals implanted with the device after creation of tricuspid regurgitation are necessary to prove the haemodynamic benefit of this procedure. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  13. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    abnormal supra-aortic vascular anatomy or pathology. We further conclude that elective patients undergoing planned coverage of the LSA during TEVAR should receive prophylactic LSA transposition or LSA-to-left-common-carotid-artery (LCCA) bypass surgery to prevent severe neurological complications...

  14. Feasibility of three-dimensional magnetic resonance angiography-fluoroscopy image fusion technique in guiding complex endovascular aortic procedures in patients with renal insufficiency.

    Science.gov (United States)

    Schwein, Adeline; Chinnadurai, Ponraj; Shah, Dipan J; Lumsden, Alan B; Bechara, Carlos F; Bismuth, Jean

    2017-05-01

    fusion was 4:09 ± 01:31 min:sec. Total fluoroscopy time was 20.1 ± 6.9 minutes. Five of 10 patients (50%) underwent stent graft deployment without any predeployment DSA acquisition. Three of six vessels (50%) were cannulated under image fusion guidance without any precannulation DSA runs, and the remaining vessels were cannulated after one planning DSA acquisition. Qualitative evaluation showed 14 of 22 virtual landmarks (63.6%) from MRA overlaid on fluoroscopy were completely accurate, without the need for adjustment. Five of eight incorrect virtual landmarks (iliac and visceral arteries) resulted from vessel deformation caused by endovascular devices. Ferumoxytol or gadolinium-enhanced MRA imaging and image fusion with fluoroscopy using noncontrast CBCT is feasible and allows patients with renal insufficiency to benefit from optimal guidance during complex endovascular aortic procedures, while preserving their residual renal function. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  15. Thoracic Endovascular Repair of Complicated Penetrating Aortic Ulcer: An 11-Year Single-Center Experience.

    Science.gov (United States)

    Jánosi, Rolf Alexander; Gorla, Riccardo; Tsagakis, Konstantinos; Kahlert, Philipp; Horacek, Michael; Bruckschen, Florian; Dohle, Daniel-Sebastian; Jakob, Heinz; Schlosser, Thomas; Eggebrecht, Holger; Bossone, Eduardo; Erbel, Raimund

    2016-02-01

    To analyze an 11-year single-center experience of treating complicated penetrating aortic ulcer (PAU) using thoracic endovascular aortic repair (TEVAR). This study included 63 consecutive patients (mean age 69.1±11.5 years; 40 men) with complicated PAU (42 symptomatic, 22 with rupture) who underwent TEVAR between 2002 and 2013. The PAUs were located in the aortic arch (n=11), the descending thoracic aorta (n=43), and the thoracoabdominal aorta (n=9). TEVAR was performed within 14 days of diagnosis in 33 (52.3%) cases (19 ruptures treated immediately); the other 30 (47.6%) patients had an average interval between diagnosis and intervention of 40±39 days. Technical success was 98.4% (62/63). One patient had a type I endoleak after stent-graft repair of a PAU in the aortic arch without great vessel transposition; another procedure was required for carotid-subclavian bypass and proximal stent-graft extension. No patient experienced spinal cord ischemia after TEVAR. Five (7.9%) patients died in-hospital; 3 had severe cardiac complications, 1 died from complications of aortic rupture, and the other succumbed to septic shock. Mean follow-up was 45.6±47.2 months, during which 12 (19.0%) patients needed a secondary intervention because of late endoleaks (n=4, 6.3%) or new complications due to disease progression. Multivariate analysis indicated that a PAU depth >15 mm was an independent predictor of mortality (hazard ratio 6.92, p=0.03). In the biomarker analysis, symptomatic patients had significantly higher D-dimer and troponin levels compared to asymptomatic patients [559.5±460.7 vs 283.2±85.2 µg/L (p=0.016) and 0.22±0.61 vs 0.02±0.03 ng/mL (p=0.04), respectively]. Patients with PAU suffer from underlying severe atherosclerotic disease and have a significant number of cardiovascular comorbidities that lead to relevant mortality and morbidity after TEVAR. As a PAU diameter >15 mm represented high risk for disease progression, these patients may be candidates for

  16. Role of graft oversizing in the fixation strength of barbed endovascular grafts.

    Science.gov (United States)

    Kratzberg, Jarin A; Golzarian, Jafar; Raghavan, Madhavan L

    2009-06-01

    The role of endovascular graft oversizing on risk of distal graft migration following endovascular aneurysm repair for abdominal aortic aneurysm is poorly understood. A controlled in vitro investigation of the role of oversizing in graft-aorta attachment strength for endovascular grafts (EVGs) with barbs was performed. Barbed stent grafts (N = 20) with controlled graft oversizing varying from 4-45% were fabricated while maintaining other design variables unchanged. A flow loop with physiological flow characteristics and a biosynthetic aortic aneurysm phantom (synthetic aneurysm model with a bovine aortic neck) were developed. The stent grafts were deployed into the aortic neck of the bio-synthetic aortic aneurysm phantom under realistic flow conditions. Computed tomography imaging of the graft-aorta complex was used to document attachment characteristics such as graft apposition, number of barbs penetrated, and penetration depth and angle. The strength of graft attachment to the aortic neck was assessed using mechanical pullout testing. Stent grafts were categorized into four groups based on oversizing: 4-10%; 11-20%; 21-30%; and greater than 30% oversizing. Pullout force, a measure of post-deployment fixation strength was not different between 4-10% (6.23 +/- 1.90 N), 11-20% (6.25 +/- 1.84 N) and 20-30% (5.85 +/- 1.89 N) groups, but significantly lower for the group with greater than 30% oversizing (3.67 +/- 1.41 N). Increasing oversizing caused a proportional decrease in the number of barbs penetrating the aortic wall (correlation = -0.83). Of the 14 barbs available in the stent graft, 89% of the barbs (12.5 of 14 on average) penetrated the aortic wall in the 4-10% oversizing group while only 38% (5.25 of 14) did for the greater than 30% group (P barb penetration were found to be positively correlated to pullout force. Greater than 30% graft oversizing affects both barb penetration and graft apposition adversely resulting in a low pullout force in this in vitro

  17. Anastomotic pseudoaneurysms after surgical reconstruction: Outcomes after endovascular repair of symptomatic versus asymptomatic patients

    International Nuclear Information System (INIS)

    Nolz, Richard; Gschwendtner, Manfred; Jülg, Gregor; Plank, Christina; Beitzke, Dietrich; Teufelsbauer, Harald; Wibmer, Andreas; Kretschmer, Georg; Lammer, Johannes

    2012-01-01

    Purpose: To compare perioperative and follow-up outcomes of symptomatic versus asymptomatic patients following endovascular repair of anastomotic pseudoaneurysms (APAs) of the abdominal aorta and iliac arteries. Methods: We retrospectively evaluated 17 patients (two women), with a mean age of 66.2 years (range 30–83 years). Endovascular treatment was performed in ten symptomatic, and seven asymptomatic patients electively. Data included technical success, perioperative (within 30 days) mortality and morbidity, as well as stent graft-related complications, reinterventions, and survival in follow-up. Results: Bifurcated (n = 13), aortomonoiliac (n = 3) endoprosthesis and one aortic cuff were implanted with a primary technical success rate of 100%. The overall in-hospital mortality and morbidity rate was 11.8% and 35.3%. The mean survival was 36.5 (range 0–111) months. There was a clear trend toward a lower overall survival within hospital and at one and three years for symptomatic patients compared to asymptomatic patients. (47.7 (CI: 0–138.8) versus 52.6 (CI: 28.5–76.8) months (p = 0.274)). During follow-up, late stent graft related complications were observed in six patients (35.3%) necessitating eight endovascular reinterventions. Additional three patients with primary fistulas between the APA and the intestine were treated by late surgical revision. Conclusion: Endovascular therapy of APAs represents a considerable alternative to open surgical repair. Short proximal anchoring zones still pose a risk for endoleaks and unintentional overstenting of side branches with commercially available devices, but this might be overcome by use of fenestrated and branched stent grafts in elective cases.

  18. Technical and clinical success of infrarenal endovascular abdominal aortic aneurysm repair: A 10-year single-center experience

    International Nuclear Information System (INIS)

    Steingruber, I.E.; Neuhauser, B.; Seiler, R.; Greiner, A.; Chemelli, A.; Kopf, H.; Walch, C.; Waldenberger, P.; Jaschke, W.; Czermak, B.

    2006-01-01

    Objective: The aim of our retrospective study was to review our single-center experience with aortic abdominal aneurysm (AAA) repair retrospectively. Material and methods: From 1995 to 2005, 70 consecutive patients affected by AAA were treated by endovascular stent-graft repair. Mean follow-up was 23.9 months. Follow-up investigations were performed at 6 and 12 months and yearly thereafter. Five different stent-graft designs were compared to each other. Primary technical success (PTS), assisted primary technical success (APTS), primary clinical success (PCS) and secondary clinical success (SCS) were evaluated. Results: All over PTS was achieved in 94.3%, APTS in 97.1%, PCS in 61.4%, APCS in 64.3% and SCS in 70%. There were 3 type I endoleaks, 25 type II endoleaks, 4 type III endoleaks, 8 limb problems, 5 conversions to open surgery, 10 aneurysm sac expansions and 14 device migrations. Patients with newer generation devices showed better results than patients with first generation prosthesis. In addition results were better for grafts with suprarenal fixation (versus infrarenal fixation) and grafts with barbs and hooks (versus grafts without barbs and hooks). Patients with bad anatomic preconditions showed a higher complication rate. Conclusion: Contrary to first generation products, new stent-graft designs show acceptable technical and clinical results in endovascular AAA aneurysm repair. However, this therapy still should be reserved only for patients with significant comorbities and suitable anatomic conditions

  19. Technical and clinical success of infrarenal endovascular abdominal aortic aneurysm repair: A 10-year single-center experience

    Energy Technology Data Exchange (ETDEWEB)

    Steingruber, I.E. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria)]. E-mail: iris.steingruber@uibk.ac.at; Neuhauser, B. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Seiler, R. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Greiner, A. [Department of Vascular Surgery, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Chemelli, A. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Kopf, H. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Walch, C. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Waldenberger, P. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Jaschke, W. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria); Czermak, B. [Department of Radiology, University Hospital Innsbruck, Anichstr. 35, A-6020 Innsbruck (Austria)

    2006-09-15

    Objective: The aim of our retrospective study was to review our single-center experience with aortic abdominal aneurysm (AAA) repair retrospectively. Material and methods: From 1995 to 2005, 70 consecutive patients affected by AAA were treated by endovascular stent-graft repair. Mean follow-up was 23.9 months. Follow-up investigations were performed at 6 and 12 months and yearly thereafter. Five different stent-graft designs were compared to each other. Primary technical success (PTS), assisted primary technical success (APTS), primary clinical success (PCS) and secondary clinical success (SCS) were evaluated. Results: All over PTS was achieved in 94.3%, APTS in 97.1%, PCS in 61.4%, APCS in 64.3% and SCS in 70%. There were 3 type I endoleaks, 25 type II endoleaks, 4 type III endoleaks, 8 limb problems, 5 conversions to open surgery, 10 aneurysm sac expansions and 14 device migrations. Patients with newer generation devices showed better results than patients with first generation prosthesis. In addition results were better for grafts with suprarenal fixation (versus infrarenal fixation) and grafts with barbs and hooks (versus grafts without barbs and hooks). Patients with bad anatomic preconditions showed a higher complication rate. Conclusion: Contrary to first generation products, new stent-graft designs show acceptable technical and clinical results in endovascular AAA aneurysm repair. However, this therapy still should be reserved only for patients with significant comorbities and suitable anatomic conditions.

  20. Endovascular treatment of a spontaneous aneurysm in the axillary artery.

    Science.gov (United States)

    Park, Sung Kyun; Hwang, Jeong Kye; Park, Sun Cheol; Kim, Sang Dong

    2015-01-01

    Spontaneous aneurysm in the axillary artery is extremely rare. The standard treatment for axillary artery aneurysm has been surgical repair, but endovascular management of select aneurysms using stent grafts has become more prevalent with the development of endoluminal technology. We report the case of a 36-year old man with a spontaneous aneurysm in the axillary artery. He experienced a tingling sensation and intermittent pain in the left upper extremity and had no history of trauma to the axilla. We performed endovascular treatment [placement of a Viabahn stent graft (W.L. Gore & Associates, Flagstaff, AZ, USA)] for a spontaneous aneurysm in the axillary artery. Following the procedure, his symptoms disappeared completely. After 6, 12 and 24 months, we carried out computed tomography angiography; all scans showed no complications. Now, the patient has no symptoms related to aneurysm in the axilla. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Endovascular Placement of an Extraluminal Femoropopliteal Bypass Graft in Human Cadavers

    International Nuclear Information System (INIS)

    Maynar, Manuel; Llorens, Rafael; Lopez-Sanchez, Carmen; Garcia-Martinez, Virginio; Qian Zhong; Lopera, Jorge; Castaneda, Wilfrido R.

    2005-01-01

    Purpose. A method to create an extraluminal femoropopliteal bypass graft using endovascular techniques was evaluated in situ on cadaver extremities in an attempt to develop a minimally invasive alternative technique for the management of infrainguinal occlusive arterial disease. Methods. The endovascular placement of an extraluminal femoropopliteal bypass graft was undertaken in 5 cadaver legs. Following percutaneous access to the popliteal artery (PA) or common femoral artery (CFA), a Rosch-Uchida needle was used to perforate the vascular wall, followed by the creation of an extraluminal tract using a looped wire and catheter. Once the desired level was reached the needle was again used to perforate the vascular wall of the proximal superficial femoral artery (SFA) or PA depending on the access used. Self-expanding expanded polytetrafluoroethylene (ePTFE) stent-grafts were then deployed to establish the extraluminal femoropopliteal bypass connecting the two arterial puncture sites. Following dilatation of the stent-graft, angiography was performed to assess the endoprostheses and to look for contrast leaks. Results. Technical success was achieved in all 5 legs. Procedure time varied from 15 to 30 min. The angiographic studies performed immediately after completion of the bypass procedure showed patency of the grafts with no evidence of kinking or leakage in any of the cases. Conclusion. This study has proved that the endovascular placement of an extraluminal femoropopliteal bypass graft in human cadaver legs using endovascular techniques under fluoroscopic control is technically feasible

  2. Endovascular repair of aortic isthmus coarctation with a self-expanding covered stent.

    Science.gov (United States)

    Oberhuber, Alexander; Muehling, Bernd M; Orend, Karl-Heinz; Schelzig, Hubert

    2012-05-01

    Coarctation is one of the most often seen congenital aortal defects. In the majority, diagnosis will be made in newborns. Endovascular repair is critical in children owing to their growth, but in adult patients, it is an interesting alternative. A 31-year-old man presenting with hypertension of upper extremities and pulseless lower extremities was admitted to our hospital. Systolic blood pressure was 190 mm Hg, although a triple antihypertensive medication was administered. Computed tomographic angiography showed a nearly total occlusion of the aortic isthmus. Coarctation was treated by an endovascular approach with a self-expanding covered stent-graft (Medtronic Talent; Medtronic World Medical, Sunrise, FL) after predilatation with a Reliant balloon (Medtronic World Medical, Sunrise, FL). After a follow-up of 40 months, the patient is normotensive and antihypertensive medication could be reduced. Lower extremities showed normal pulses and normal ankle-brachial index. Computed tomographic scans showed unchanged stent-graft position, with constant slight waist. Endovascular repair of atresia or coarctation of the thoracic aorta is a minimal invasive debatable option. Not only reduction of blood pressure but also reduction of left ventricular mass and prolongation of life expectancy can be achieved by endovascular treatment. Copyright © 2012 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  3. Stent-graft repair for blunt traumatic aortic injury: functional and survival outcomes.

    Science.gov (United States)

    González Sánchez, S; Martín Conejero, A; Moñux Ducajú, G; Martínez López, I; Hernando Rydings, M; Serrano Hernando, F J

    2013-02-01

    Traumatic aortic injury is usually lethal, most often because of serious associated wounds. The short- and midterm outcome of endovascular exclusion was assessed as the current treatment of choice due to a lower mortality and morbidity than open surgical treatment. We reviewed the cases of 8 patients (5 male, mean age 33 years) undergoing endovascular repair of a traumatic thoracic aortic lesion, confirmed by computed tomographic angiography, at our centre. Most patients showed a contained lesion limited to the aortic isthmus and severe associated injuries. Intrahospital mortality was 37.5% (N.=3) and mostly due to posttraumatic brain injury (N.=2). Most patients were hemodynamically stable at the time of endovascular repair (N.=6). The median time to surgery was 12 hours (3-48 hours). The endografts used were TAG® (W.L. Gore and Associates, Flagstaff) in three patients, and Valiant® (Medtronic, Santa Rosa, CA) in four. The technical success rate was 100%. In one case, the left subclavian artery was occluded without signs of arm ischemia. There were no cases of paraplegia or stroke related to treatment. No revision procedures were needed during follow-up. Endovascular repair shortly after injury seems to be effective and safe with a low associated morbidity and mortality.

  4. Emergency Endovascular Treatment of an Acute Traumatic Rupture of the Thoracic Aorta Complicated by a Distal Low-Flow Syndrome

    International Nuclear Information System (INIS)

    Bruninx, Guy; Wery, Didier; Dubois, Eric; El Nakadi, Badih; Dueren, Eric van; Verhelst, Guy; Delcour, Christian

    1999-01-01

    We report the case of a patient who suffered major trauma following a motorcycle accident that resulted in multiple fractures, bilateral hemopneumothorax, pulmonary contusions, and an isthmic rupture of the aorta with a pseudoaneurysm compressing the descending aorta. This compression was responsible for distal hypotension and low flow, leading to acute renal insufficiency and massive rhabdomyolysis. Due to the critical clinical status of the patient, which prevented any type of open thoracic surgery, endovascular treatment was performed. An initial stent-graft permitted alleviation of the compression and the re-establishment of normal hemodynamic conditions, but its low position did not allow sufficient coverage of the rupture. A second stent-graft permitted total exclusion of the pseudoaneurysm while preserving the patency of the left subclavian artery

  5. Remodeling of the aortic neck with a balloon-expandable stent graft in patients with complicated neck morphology.

    Science.gov (United States)

    Kolvenbach, Ralf; Pinter, Laslo; Cagiannos, Catherine; Veith, Frank J

    2008-01-01

    Graft migration and other device-related problems are more frequent in abdominal aortic aneurysm (AAA) patients with a complicated neck. We wanted to evaluate the performance of a balloon-expandable stent graft in these cases. Complicated aortic neck morphology was defined as a combination of short (45 degrees) necks with or without circumferential thrombus. Severe aortic angulation was defined as less than 120 degrees. During a 24-month period, 18 consecutive patients with complicated neck anatomy were treated with the Vascular Innovations (VI)-Datascope balloon-expandable endograft. In two patients, a balloon-expandable cuff was implanted to remodel the neck prior to insertion of a bifurcated endograft (Excluder, W.L. Gore & Associates, Flagstaff, AZ). Demographic, procedural, and outcome data were collected prospectively and retrospectively analyzed. All patients had preoperative computed tomographic (CT) angiography to determine aortic neck angulation and were followed with duplex ultrasonography and CT every 3 and 6 months postoperatively to assess aortic neck and sac dilatation, as well as device migration. The VI-Datascope graft consists of an aortounifemoral polytetrafluoroethylene (PTFE) graft sutured to a proximal balloon-expandable stent. The length of the graft is 40 cm; thus, the distal end of the graft always protrudes through the ipsilateral arteriotomy and can be cut to an appropriate length for each patient. The covered portion of the graft was deployed just below the level of the lowest renal artery. The proximal bare metal stent was deployed in the suprarenal area. An endoluminal hand-sewn anastomosis was performed between the aortounifemoral limb and the distal external iliac or the common femoral arteries. An occluder device was placed in the contralateral common iliac artery to prevent retrograde perfusion of the aneurysm. A femorofemoral 8 mm Dacron graft bypass was then performed to establish flow to the contralateral extremity and pelvis

  6. A bad experience with endovascular treatment of an aortobronchial fistula.

    Science.gov (United States)

    Eldien, Altarabsheh Salah; Deo, Salil; Nichols, Francis C; Greason, Kevin L

    2012-02-01

    A 35-year-old woman presented with an aortobronchial fistula after polyester graft replacement of coarctation of the descending thoracic aortic. Treatment of the fistula included antibiotic therapy and stent graft placement. Life-threatening sepsis developed in the postoperative period. Subsequent treatment required excision of the infected graft complex with extra-anatomic reconstruction of the thoracic aorta. The patient had a very stormy postoperative course and required heroic measures, including mechanical circulatory support, to achieve survival. The present case demonstrates failure of endovascular therapy of an aortobronchial fistula. The case should serve as a cautious reminder that the underlying cause for infection remains even after apparent successful endovascular therapy. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Endovascular treatment of acute type B dissection complicating aortic coarctation.

    Science.gov (United States)

    Kassaian, Seyed Ebrahim; Abbasi, Kyomars; Mousavi, Mehdi; Sahebjam, Mohammad

    2013-01-01

    Surgical treatment poses a high risk to patients with concomitant aortic coarctation and dissection, and an interventional approach could be an alternative. We describe the case of a 52-year-old man with a long history of untreated hypertension and aortic coarctation who emergently presented at our institution with an acute Stanford type B dissection. The patient's elevated serum creatinine level, perfusion deficit in the right lower limb, and hypertension did not respond to medical therapy, and he did not consent to surgery. By endovascular means, we used a self-expandable stent-graft to cover the entry point of the dissection; then, we deployed a balloon-expandable bare-metal stent to correct residual stenosis. To our knowledge, this is the first report of the endovascular treatment of aortic coarctation complicated by type B dissection.

  8. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    International Nuclear Information System (INIS)

    Sun, Zhonghua; Chaichana, Thanapong

    2010-01-01

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair

  9. Endovascular repair of pseudoaneurysms after open surgery for aortic coarctation.

    Science.gov (United States)

    Kotelis, Drosos; Bischoff, Moritz S; Rengier, Fabian; Ruhparwar, Arjang; Gorenflo, Matthias; Böckler, Dittmar

    2016-01-01

    To analyse early and long-term results of thoracic endovascular aortic repair (TEVAR) in patients with pseudoaneurysms after open aortic coarctation (CoA) repair. A total of 11 patients of 418 patients who had been treated with TEVAR during the period from January 1998 to April 2015 (8 males; median age 53 years) were retrospectively analysed. Dacron patch aortoplasty was primarily performed in 9 patients and subclavian flap aortoplasty in 2 patients. Seven of the 11 patients had asymptomatic pseudoaneurysms (median diameter 56 mm, range 20-65 mm) diagnosed by routine screening. Symptomatic patients presented with haemoptysis, lower limb ischaemia, haemodynamic collapse and back pain and underwent emergency repair (4/11). Adjunctive procedures at the proximal landing zone were required in 7/11 patients. The median number of implanted endoprostheses per patient was 1 (range: 1-5). The median follow-up was 60 months (range 6-161 months). Technical success was achieved in 91% (10/11; 1 secondary elective open conversion). The 30-day mortality was 0%. The stroke rate was 18% (2 non-disabling strokes). In 2 patients (20%), stent-graft displacement during deployment was observed. The reintervention rate was 33% (Type Ib endoleak, left arm claudication, partial coverage of the left common carotid artery). Clinical success during follow-up was achieved in 10/11 patients. In 9/10 patients, aneurysm sac shrinkage was observed. The Type II endoleak rate was 10% (1/10; intercostal artery). The overall mortality rate was 9% (1 patient died of amyotrophic lateral sclerosis). Endovascular treatment of post-coarctation pseudoaneurysms is feasible in elective and emergency cases, yielding durable results in the long term. Due to anatomical specifics, implantation may be challenging and requires careful procedural planning. On-site cardiothoracic surgery backup is essential in case open conversion is required. © The Author 2015. Published by Oxford University Press on behalf of the

  10. Continuous Flow Perfused Cadaver Model for Endovascular Training, Research, and Development.

    Science.gov (United States)

    Sarkar, Amrita; Kalsi, Richa; Ayers, Joseph D; Drucker, Charles B; Kaushal, Vaidehi; Sutton, William; Crawford, Robert S

    2018-04-01

    Endovascular simulation employing computer, animal, and static models are common and useful adjuncts for teaching endovascular procedures and developing novel, complex endovascular techniques. Unfortunately, these models lack realistic haptic feedback and thus do not faithfully replicate many of the technical challenges associated with clinical endovascular procedures (e.g., arterial calcification, rigidity, and stenosis). We sought to develop a realistic and reproducible perfused cadaver model for endovascular training, device development, and research. Fresh frozen, elderly (age 50-80 years) male cadavers were thawed and prepared for open dissection. The entire arterial tree (ascending aorta to femoral arteries) was dissected free and major branch vessels exposed. Sheaths were placed to allow outflow from selected vessels. A Dacron conduit was sewn to the ascending aorta to generate arterial inflow, which was provided by a centrifugal pump. Aortic aneurysms were created in the descending thoracic and abdominal aorta. Digital subtraction arteriography and various endovascular interventions were performed, including stent grafts and EndoAnchors deployment. Continuous antegrade flow was achieved in the thoracic, abdominal, iliac, and femoral segments. Open and percutaneous access at the femoral region was obtained with realistic back-bleeding and tactile feedback. Adequate, fluoroscopically documented flow was observed in both cannulated major and noncannulated smaller branches. We performed angiography with standard techniques via a pigtail catheter and contrast injector throughout the arterial system. Abdominal and thoracic endografts were deployed with appropriate angiographic guidance and realistic haptic feedback for both guidewire and stent grafts. Additional applications, including selective cannulation, aorto-iliac occlusive disease interventions, and anchor placement, were also successfully simulated. Finally, the model was used as a platform to test

  11. Endovascular treatment of acute type B dissection complicating graft-bypass repair for aortic coarctation

    Directory of Open Access Journals (Sweden)

    Serkan Ertugay

    Full Text Available Objectives: The early dissection of the descending aorta after the repair of aortic coarctation is very rare. Herein, we present a special endovascular technique used for acute type B dissection complicating graft bypass for aortic coarctation. Methods: The 48 year-old male patient with the diagnosis of adult type aortic coarctation had bypass procedure between the aortic arch and the descending aorta. Six weeks after the first operation, the patient was readmitted with severe back pain and had the diagnosis of acute type B dissection which involved the descending aorta at the distal part of the graft anastomosis. Results: Two separate stent-grafts were deployed respectively 31 × 150 mm and 34 × 200 mm (C-TAG™ WL Gore&Asc., Flagstaff, AZ, USA. The previous Dacron bypass graft was used as a proximal landing zone for the first stent-graft. The distal landing zone for the second stent was the area between the celiac trunk and superior mesenteric artery. Therefore, the covered stent-graft was implanted to the celiac trunk (Viabahn™ 7 × 50 mm WL Gore&Asc, AZ, USA to maintain its patency before the deployment of the second graft. The segment of coarctation was closed with a vascular plug (Amplatzer™ vascular plug II to prevent persistent perfusion of aneurysmal false lumen. Conclusion: The endovascular approach offers multiple less invasive options based on a patient-specific problem. Keywords: Aortic coarctation, Bypass graft, Endovascular, Vascular plug

  12. Type 1a endoleak following Zone 1 and Zone 2 thoracic endovascular aortic repair: effect of bird-beak configuration.

    Science.gov (United States)

    Kudo, Tomoaki; Kuratani, Toru; Shimamura, Kazuo; Sakamoto, Tomohiko; Kin, Keiwa; Masada, Kenta; Shijo, Takayuki; Torikai, Kei; Maeda, Koichi; Sawa, Yoshiki

    2017-10-01

    Type 1a endoleak is one of the most severe complications after thoracic endovascular aortic repair (TEVAR), because it carries the risk of aortic rupture. The association between bird-beak configuration and Type 1a endoleak remains unclear. The purpose of this study was to analyse the predictors of Type 1a endoleak following Zone 1 and Zone 2 TEVAR, with a particular focus on the effect of bird-beak configuration. From April 2008 to July 2015, 105 patients (mean age 68.6 years) who underwent Zone 1 and 2 landing TEVAR were enrolled, with a mean follow-up period of 4.3 years. The patients were categorized into 2 groups, according to the presence (Group B, n = 32) or the absence (Group N, n = 73) of bird-beak configuration on the first postoperative multidetector computed tomography. The Kaplan-Meier event-free rate curve showed that Type 1a endoleak and bird-beak progression occurred less frequently in Group N than in Group B. Five-year freedom from Type 1a endoleak rates were 79.7% and 100% for Groups B and N, respectively (P = 0.007). Multivariable logistic regression analysis showed that dissecting aortic aneurysm (odds ratio 3.72, 95% confidence interval 1.30-11.0; P = 0.014) and shorter radius of inner curvature (odds ratio 1.09, 95% confidence interval 0.85-0.99; P = 0.025) were significant risk factors for bird-beak configuration. Multivariable Cox proportional hazard regression showed that Z-type stent graft (hazard ratio 2.69, 95% confidence interval 1.11-6.51; P = 0.030) was a significant risk factor for bird-beak progression. Appropriate stent grafts need to be chosen carefully to prevent Type 1a endoleak and bird-beak configuration after landing Zone 1 and 2 TEVAR. Patients with bird-beak configuration on early postoperative multidetector computed tomography require closer follow-up to screen for Type 1a endoleak. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio

  13. Aortic aneurysm endovascular treatment with the parallel graft technique from the aortic arch to the iliac axis.

    Science.gov (United States)

    Fadda, Gian F; Marino, Mario; Kasemi, Holta; DI Angelo, Costantino L; Dionisi, Carlo P; Cammalleri, Valeria; Setacci, Carlo

    2017-05-26

    The chimney technique has been developed for the treatment of complex aortic aneurysms. We analyzed the midterm to long-term outcomes of this approach from a single- centre experience. From October 2008 to July 2016, 58 patients underwent endovascular aortic aneurysm repair using the chimney technique. Indications for treatment were thoracic aortic aneurysm (TAA) (n = 11), thoracoabdominal aortic aneurysm (TAAA) (n = 2), pararenal aortic aneurysm (PAAA) (n= 15), aortoiliac/isolated hypogastric artery aneurysm (n = 25), type I endoleak after previous TEVAR/EVAR (n=4), proximal pseudoaneurysm after AAA open repair (n = 1). Elective (82.8%) and emergent (17.2%) procedures were included. The immediate technical success was 100%. Single, double and triple chimneys were performed in 46, 10 and 2 patients, respectively. Overall, 61 target vessels (3 left common carotid arteries, 8 left subclavian arteries, 3 celiac trunks, 3 superior mesenteric arteries, 19 renal arteries and 25 hypogastric arteries) were involved. Post-operative mortality was 0. No neurologic complications were registered. Primary patency rate of the chimney stent/stent graft was 98.3%. Low flow type I endoleak was observed in 4 patients (6.9%). Post-operative chimney graft re-intervention rate was 1.7%. The median follow up was 32±20 months (range 3- 96 months). Overall estimated survival at 12, 50 and 80 months was 100%, 89% and 44%, respectively. Estimated freedom from endoleak at 1, 12, 24 and 36 months was 96.5%, 95%, 95% and 93%, respectively. One HA stent graft occluded at the 3rd month of follow up. No reintervention was performed. Our experience with the chimney technique for aortic aneurysms from the aortic arch to the iliac axis shows promising and durable mid- and long term results. Endograft oversizing, associated with the chimney graft diameter and length choice remain fundamental to reduce the risk of the most frequent procedure complications: type I endoleak and CG occlusion.The wider

  14. Thoracic aortic stent-graft placement combined with left subclavian artery 'chimney operation': therapeutic analysis of 15 cases with insufficient proximal anchor area

    International Nuclear Information System (INIS)

    Liu Jiayi; Huang Lianjun; Fan Zhanming; Zhang Zhaoqi

    2012-01-01

    Objective: To discuss the strategies for the management of insufficient proximal anchoring area during the performance of transluminal stent-graft placement (TSGP), and to evaluate the feasibility of intentional coverage of the left subclavian artery (LSA) together with left subclavian artery stent-graft placement by using 'chimney operation' technique. Methods: A total of 15 patients with thoracic aortic diseases complicated by insufficient proximal anchoring area, who were encountered in authors' hospital during the period from Dec. 2009 to April 2011, were enrolled in this study. The clinical data were retrospectively analyzed. The thoracic aortic diseases included aortic dissection (n=6), aortic pseudoaneurysm (n=1), aortic aneurysm (n=4) and penetrating ulcer (n=4). Of the 15 patients, the distance between the lesion and LSA anchoring site 15 mm in 2. TSGP was carried out. The ostium of LSA was intentionally and completely covered by thoracic aortic stent-graft and left subclavian artery stent-graft placement was subsequently performed. The patients were kept under observation for symptoms of cerebral and upper limb ischemia. The postoperative complications such as endoleak and the patency of LSA were assessed with angiography. Results: Thoracic aortic stent-graft placement was successfully carried out in all 15 patients. In addition, one 'chimney' stent was properly implanted in LSA in each patient. After the procedure, no complications of nervous system or severe ischemia of upper extremity occurred. Follow-up examinations performed between 5 days to 3 months after the treatment revealed that the aortic stent-graft remained in stable condition and no type Ⅰ endoleak occurred, meanwhile the blood flow in 'chimney' stent was unobstructed. Conclusion: Intentional LSA coverage with 'chimney operation' can expand the applicability of TSGP with high tolerability. It is especially useful for patients with left vertebral artery blood supply dominance or with

  15. JAG Tearing Technique with Radiofrequency Guide Wire for Aortic Fenestration in Thoracic Endovascular Aneurysm Repair

    International Nuclear Information System (INIS)

    Ricci, Carmelo; Ceccherini, Claudio; Leonini, Sara; Cini, Marco; Vigni, Francesco; Neri, Eugenio; Tucci, Enrico; Benvenuti, Antonio; Tommasino, Giulio; Sassi, Carlo

    2012-01-01

    An innovative approach, the JAG tearing technique, was performed during thoracic endovascular aneurysm repair in a patient with previous surgical replacement of the ascending aorta with a residual uncomplicated type B aortic dissection who developed an aneurysm of the descending thoracic aorta with its lumen divided in two parts by an intimal flap. The proximal landing zone was suitable to place a thoracic stent graft. The distal landing zone was created by cutting the intimal flap in the distal third of the descending thoracic aorta with a radiofrequency guide wire and intravascular ultrasound catheter.

  16. David M. Hume Memorial Lecture. Impact of endovascular technology on the practice of vascular surgery.

    Science.gov (United States)

    Veith, F J; Marin, M L

    1996-08-01

    Endovascular treatment techniques have already replaced some vascular operations. The likelihood is that new endovascular techniques involving stents and stented grafts will replace additional vascular operations. All these treatments involve the use of catheter-guidewire, balloon, and imaging modalities, particularly digital fluoroscopy. These modalities have already and will increasingly help to improve and simplify standard vascular operations such as thromboembolectomy, infrainguinal bypasses, and management of aneurysms and arteriovenous fistulas. Accordingly, vascular surgeons must become familiar with and use these endovascular methods and techniques. This can be accomplished in a variety of ways which includes working as part of a multidisciplinary vascular treatment group in which various specialists collaborate to provide the best, most cost-effective care to vascular disease patients.

  17. Endovascular repair of postoperative vascular graft related complications after aorto-iliac surgery

    DEFF Research Database (Denmark)

    Duvnjak, Stevo; Andersen, P E; Larsen, K E

    2014-01-01

    with anastomotic pseudoaneurysms without leak, of which three had proximal anastomotic pseudoaneurysms and one had distal iliac anastomotic pseudoaneurysm. Implanted stent graft were Endurant (Medtronic) bifurcated endoprostheses in three patients and Excluder (Gore) prosthesis in a two cases. Tubular Medtronic....... The mortality and morbidity is higher compared to the initial treatment. We present twelve patients with these complications which were treated by an endovascular approach. METHODS: From January 2008 through January 2013 our radiological records were searched for cases with post surgical vascular complications...... treated with endovascular intervention. These comprised of anastomotic pseudoaneurysm, suture leakage and arterial enteric fistulas. Patients with limb occlusions were not included in this study. RESULTS: Twelve patients with graft related complications treated with endovascular intervention were recorded...

  18. Morphological risk factors of stroke during thoracic endovascular aortic repair.

    Science.gov (United States)

    Kotelis, Drosos; Bischoff, Moritz S; Jobst, Bertram; von Tengg-Kobligk, Hendrik; Hinz, Ulf; Geisbüsch, Philipp; Böckler, Dittmar

    2012-12-01

    This study aims to identify independent factors correlating to an increased risk of perioperative stroke during thoracic endovascular aortic repair (TEVAR). A prospective maintained TEVAR database, medical records, and imaging studies of 300 patients (205 men; median age of all, 66 years, range 21-89), who underwent TEVAR between March 1997 and February 2011, were reviewed. Preoperative CT data sets were reviewed by two experienced radiologists with focus on the atheroma burden in the aortic arch (grade I, normal, to grade V, ulcerated or pedunculated atheroma). Aortic arch geometry (arch types I-III) was documented. Further parameters included in the univariate analysis were age, gender, urgency of repair, duration of procedure, adenosine-induced cardiac arrest or rapid pacing, proximal landing zone, left subclavian artery (LSA) coverage, and number of stent grafts. Multivariate logistic regression analysis was performed to assess the independent correlations of potential risk factors. Atherosclerotic aneurysm was the most common pathology (44%). One hundred and fifty-four of our patients (51%) were treated under urgent or emergent conditions. Seventeen percent of all patients had significant arch atheroma (grade IV or V), and 43% had a steep type III aortic arch. The perioperative stroke was 4% (12 patients; median age, 73 years, range 31-78). Two strokes were lethal (0.7%). All strokes were classified as embolic based on imaging characteristics. In eight patients, strokes were located in the left cerebral hemisphere (seven of them in the anterior and one in the posterior circulation). Four stroke patients (one in the left posterior circulation) underwent LSA coverage without revascularization. Three stroke patients had severe arch atheroma grade V. Five patients suffering stroke were recognized to have a type III aortic arch. Strokes were equally distributed between zones 0-2 vs. 3-4 (n = 6 each, 5 vs. 3.3%). The highest incidence was found in zone 1 (11

  19. Thoracic endovascular aortic repair migration and aortic elongation differentiated using dual reference point analysis.

    Science.gov (United States)

    Alberta, Hillary B; Takayama, Toshio; Panthofer, Annalise; Cambria, Richard P; Farber, Mark A; Jordan, William D; Matsumura, Jon S

    2018-02-01

    We evaluated images of patients undergoing a thoracic endovascular aortic repair procedure using two reference points as a means for differentiating stent graft migration from aortic elongation. Conventional standards define migration of a stent graft as an absolute change in the distance from the distal graft ring to a distal landmark ≥10 mm compared with a baseline measurement. Aortic elongation occurs over time in both healthy individuals and patients with aortic disease. Aortic elongation in patients with stent grafts may result in increased distal thoracic aortic lengths over time. False-positive stent graft migration would be defined when these patients meet the standard definition for migration, even if the stent has not moved in relation to the elongating aorta. This retrospective study evaluated the aortic length of 23 patients treated with the conformable GORE TAG thoracic endoprosthesis (W. L. Gore & Associates, Flagstaff, Ariz) in three clinical trials (dissection, traumatic injury, and aneurysm). Patients who met the standard definition for migration were selected. A standardized protocol was used to measure aortic centerline lengths, including the innominate artery (IA) to the most distal device ring, the IA to the celiac artery (CA), and the distal ring to the CA. Baseline lengths obtained from the first postoperative image were compared with length measurements obtained from the first interval at which they met the standard definition for migration. The conventional standards for migration using a single reference point were compared with the use of dual reference points. Of the 23 patients with endograft changes, 20 were deemed to have aortic elongation rather than true migration. The remaining three patients were deemed to have migration on the basis of the IA to distal ring position compared with the IA to CA length change. The IA to CA interval length change was markedly greater in those with elongation compared with migration (23.8 ± 8.4

  20. Evaluating the in situ loading and accelerated durability of barbs located on bifurcated aorto-iliac stent-grafts.

    Science.gov (United States)

    Conti, J C; Strope, E R

    2000-01-01

    A special three-part protocol has been generated for the isolated durability testing of stent barbs. This triple protocol includes an initial evaluation on a cardiovascular duplicator to determine the loading per barb that occurs during normal flow through the stent-graft. The next stage of this protocol determined the frequency response characteristics of the bending point where the barb attaches to the stent to allow for the determination of the appropriate frequency to carry out the accelerated testing. The final part of the test includes high speed bend testing at frequencies determined in the second part of the methods to determine the long term durability of the isolated barb stent unit. The results of this testing indicated that under normal cardiovascular conditions each barb is experiencing a loading of 20 grams peak during maximum forward flow. Loading the isolated barb/stent segment at 600 beats per minute (bpm) for 400 million cycles indicated no tendency for these barbs to experience a change in physical properties. During this testing there were no barbs that broke.

  1. Endovascular management of peripheral arterial trauma in patients presenting in hemorrhagic shock.

    Science.gov (United States)

    Trellopoulos, G; Georgiadis, G S; Aslanidou, E A; Nikolopoulos, E S; Pitta, X; Papachristodoulou, A; Lazarides, M K

    2012-08-01

    This study investigated patients who sustained peripheral arterial trauma, presented with clinical signs of shock, and underwent urgent endovascular repair (endo-R). Eighteen patients (11 men) aged 62.8 ± 17.5 y (range: 24-78 years) with severe peripheral arterial injuries or spontaneous ruptures who presented with clinical signs of shock were treated on an emergency basis at two institutions from August 2003 to August 2009. The injury mechanism and clinical presentation were assessed in all patients. The time interval from the initial event to the procedure, the time interval from hemodynamic instability to endo-R (HI-to-endo-RTI), the artery involved in the approach to the injured vessel, the method of endo-R, and the endo-R duration were recorded. Stent grafting and/or embolization of the injured vessel were performed. The outcome was assessed mainly by clinical examination and duplex scanning. The duration of follow-up ranged from 6 d to 60 mo (27.4 ± 17.8 mo, mean ± SD). Mechanisms of injury included 13 iatrogenic (9 catheter-related) injuries, 2 spontaneous hemorrhages, and 1 case each of gunshot wound, fall injury, and car accident. Traumatic lesions were in the external carotid (N.=1), vertebral (N.=1), subclavian (N.=3), common iliac (N.=1), external iliac (N.=5), internal iliac (N.=3), profunda femoral (N.=1), superficial femoral (N.=2), and popliteal (N.=1) arteries. Stent grafts and embolotherapy were successfully deployed in 12 and 4 patients, respectively, with complete exclusion of the bleeding site. One patient received both treatments and another patient received balloon occlusion therapy. Technical success with no procedural complications occurred in all cases. The mean event-to-procedure time interval, HI-to-endo-RTI, and operative time were 147 min, 42.2 ± 48.2 min (range: 3-180 min), and 40.0 ± 29.6 min (range: 5-110 min), respectively. Thirteen patients had an uneventful postoperative course while three patients died (mortality rate: 17

  2. Value of spiral CT in the treatment of aortic dissection with endovascular exclusion

    International Nuclear Information System (INIS)

    Zhao Jun; Jing Zaiping; Xiao Yi; Wang Peijun

    2001-01-01

    Objective: To discuss the value of spiral CT in the preoperative evaluation of Stanford type B dissections before treated with endovascular exclusion. Methods: Thirty-one cases of consecutive Stanford type B dissecting thoracic aortic aneurysms were retrospectively studied by reviewing of the multi-reconstructive Spiral CT images. The image reconstruction methods were dimensional transverse enhanced scanning, maximum-pixel-intensity projection (MIP), surface rendered display (SSD), curved planer reformatting (CPR), and Virtual Endoscopic Imaging (VEI). Results: Sensitivity of revealing the tears of the dissection by Spiral CT was 100%. The ratio of identifying the true and false lumen was 100%. Location of the proximal tears in 29 of the 31 cases displayed on Spiral CT images were the same as that of on digital subtracting angiography, which achieved an accurate ratio of 93.5%. though the location of the proximal tears in two of the 31 cases detected by CT scanning did not match to that of DSA, the operation decision or stent-grafts selection were not affected. The detection of the range of the dissections by CT achieved a ratio of 100%, and the size chosen of the stent-graft based on CT parameters was all correct that in a ratio of 100%. Conclusion: The spiral CT is of high value in the preoperative evaluation of endovascular exclusion for thoracic aortic dissection. It can act as the routine method of choice

  3. Aortoenteric Fistula as a Complication of Open Reconstruction and Endovascular Repair of Abdominal Aorta

    Directory of Open Access Journals (Sweden)

    Marek Tagowski

    2014-01-01

    Full Text Available The paper intends to present a review of imaging characteristics of secondary aortoenteric fistula (AEF. Mechanical injury, infection, and adherence of a bowel segment to the aorta or aortic graft are major etiologic factors of AEF after open aortic repair. The pathogenesis of AEF formation after endovascular abdominal aortic repair is related to mechanical failure of the stent-graft, to stent graft infection, and to persistent pressurization of the aneurysmal sac. The major clinical manifestations of AEF comprise haematemesis, melaena, abdominal pain, sepsis, and fever. CT is the initial diagnostic modality of choice in a stable patient. However, the majority of reported CT appearances are not specific. In case of equivocal CT scans and clinical suspicion of AEF, scintigraphy, 67Ga citrate scans or 18F-FDG PET/CT is useful. Diagnostic accuracy of endoscopy in evaluation of AEF is low; nevertheless it allows to evaluate other than AEF etiologies of gastrointestinal bleeding. Without adequate therapy, AEF is lethal. Conventional surgical treatment is associated with high morbidity and mortality. The endovascular repair may be an option in hemodynamically unstable and high-risk surgical patients. We also illustrate an example of a secondary AEF with highly specific albeit rare radiologic picture from our institution.

  4. Transarterial Endoleak Closure After Endovascular Thoracoabdominal Aneurysm Repair: When the "Sandwich" Goes Wrong.

    Science.gov (United States)

    Panoulas, Vasileios F; Montorfano, Matteo; Latib, Azeem; Giustino, Gennaro; Spagnolo, Pietro; Taramasso, Maurizio; Chieffo, Alaide; Civilini, Efrem; Chiesa, Roberto; Colombo, Antonio

    2016-02-01

    To describe the use of vascular plugs to close a complex type Ib endoleak following the sandwich procedure used in conjunction with endovascular thoracoabdominal aortic aneurysm (TAAA) repair. A 59-year-old man with a 6.5-mm TAAA was treated with initial deployment proximally of 2 Zenith TX2 stent-grafts. In preparation for the sandwich technique to preserve flow to the celiac trunk, a 10×100-mm Viabahn covered stent was delivered from a brachial access into the celiac trunk unprotected by the sheath of the introducer. The trigger wire system became snagged on the struts of the distal aortic stent-graft; when the wire was pulled, the proximal end of the Viabahn migrated outside the aortic stent-graft, which migrated upward. The main body extension intended for the aortic component of the sandwich technique was deployed close to the distal end of the aneurysm sac, but a large type Ib endoleak formed in the gutter between the Viabahn, aortic extension, and sac wall. The leak perfused the celiac trunk, and the procedure was terminated. Increasing sac size on 3-month imaging prompted closure of the leak with 2 type II Amplatzer vascular plugs aiming to occlude the endoleak outflow into the Viabahn and the endoleak outflow at the site of the gutter. Imaging follow-up at 6 months demonstrated successful exclusion of the TAAA with no residual endoleak and excellent perfusion of the celiac trunk. Transarterial treatment of complex endoleaks is feasible when preceded by meticulous imaging and detailed preprocedural planning. © The Author(s) 2015.

  5. Aortic dissection. Basic aspects and endovascular management

    International Nuclear Information System (INIS)

    Jaramillo, Nicolas I; Alviar, Carlos I

    2005-01-01

    Treatment of thoracic aortic pathology is complicated by the morbidity associated to the surgical procedure and to the frailty of an elderly and difficult population. Surgical operation in this kind of population frequently bears a significant incidence of death and long-term disability. In an effort to reduce the incidence of negative outcomes, minimally invasive techniques in the form of endovascular stenting have been introduced during the past decade. The technology, originally described by Parodi, and initially designed for its use in abdominal aortic aneurysms, has been adapted for the treatment of thoracic aortic aneurysms. Furthermore, an improved understanding of the pathophysiology and the natural history of thoracic aortic disease as well as the analysis of the outcomes have facilitated our treatment decisions in terms of the timing for an appropriate intervention. Treatment of thoracic aortic dissection using endovascular Stent is one of the more recent advances in this condition and is receiving increasing attention, as it is a less invasive alternative to an open surgical repair. Although this technology is still innovative, significant improvements have been made lately in the design and deployment of the endovascular Stent-grafts. These prostheses have been increasingly used to treat aneurysms, dissections and traumatic ruptures, as well as giant penetrating ulcers and intramural hematomas of the descending thoracic aorta with good early and mid-term outcomes. The rareness, complexity and severity of the pathology and the theoretically high risk of complications should render the surgeon extremely cautious especially with young patients. Conceptually, the endo luminal treatment in the acute phase seems to be the solution and will probably become a preferred therapy while technical refinement is under way. Worldwide experience is growing and with this a better understanding of the indications and limitations of this innovative therapy will be

  6. Stent-graft repair of isolated iliac aneurysms with wide or ectatic necks with use of inverted zenith device legs.

    Science.gov (United States)

    Klonaris, Chris; Verikokos, Christos; Avgerinos, Efthimios D; Bellos, John; Katsargyris, Athanasios; Liapis, Christos D

    2009-03-01

    Although there is considerable experience in the management of iliac artery aneurysms (IAAs) accompanying abdominal aortic aneurysms, less is known about endovascular management of isolated IAAs. The distal landing zone can be secured if necessary by extending the graft to the external iliac artery, but the proximal landing zone remains a challenging issue, on which technical success is dependent. The present report describes a novel technique for endovascular management of isolated IAAs with wide proximal necks for which no commercially available grafts with fitting sizes exist: inversion of the iliac leg of a Zenith device.

  7. The education system to master endovascular aortic repair in Japan - the Japanese Committee for Stentgraft Management.

    Science.gov (United States)

    Obitsu, Y; Ishimaru, S; Shigematsu, H

    2010-03-01

    The Japanese Committee for Stentgraft Management (JACSM) was established with the aim of ensuring the safe and proper reach of commercial stent grafts following their regulatory approval. This study examines the validity of the practice standards developed by JACSM. JACSM comprises 10 associations related to endovascular treatment. Based on the practice standards developed by JACSM, the status of practising institutions, practising surgeons, supervising surgeons and the results of follow-up surveys were analysed. In the 2.5 years following the establishment of JACSM, 298 institutions have fulfilled the practice standards. The number of practising surgeons reached 493, and the number of supervising surgeons reached 177. There were 3089 registered cases up to June 2009. The present study analysed 1570 cases registered in the 2 years from July 2006 to June 2008. The hospital mortality rate was low (0.4%) in the follow-up surveys. Early results following the introduction of stent grafts were generally good. The procedure spread safely without the learning curve seen in the initial stages following introduction of new medical materials, indicating that the practice standards were appropriate.

  8. Thoracic Endovascular Aortic Repair into the False Lumen in Chronic Aortic Dissection.

    Science.gov (United States)

    Kamman, Arnoud V; Williams, David M; Patel, Himanshu J

    2017-07-01

    Deployment of a stent graft for the treatment of aortic dissections is normally performed in the true lumen. However, in some rare occasions landing in the false lumen may be appropriate. We present 2 different cases of chronic aortic dissection, where we opted to land the stent graft into the false lumen to treat the associated aneurysm. For the first case, the goal of thoracic endovascular aortic repair (TEVAR) was to exclude the aneurysm from within the false lumen because of a slit-like true lumen. In the second case, the visceral arteries came off the false lumen, with the renal vessels from the true lumen. False lumen TEVAR was performed, and the infrarenal aorta fenestrated, as to ensure adequate perfusion. These different clinical scenarios show how false lumen TEVAR for chronic dissections with associated aneurysms can be an alternative treatment approach and highlight the importance of assessing the origin of branch vessels and the possible necessity of reperfusion of these, before TEVAR is performed. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. [Case in which renal function improved following stent-graft placement in the aorta two months after the onset of stanford type B acute aortic dissection].

    Science.gov (United States)

    Fusamae, Juri; Nishino, Tomoya; Uramatsu, Tadashi; Obata, Yoko; Furusu, Akira; Sakamoto, Ichiro; Kohno, Shigeru

    2011-01-01

    A 48-year-old man was admitted to the Department of Cardiovascular Surgery in our hospital after developing Stanford type B acute aortic dissection with a patent false lumen in July 2008. Conservative treatment involving rest and antihypertensive therapy was provided following admission. Urine volume decreased from day 9, and serum creatinine increased to 7.7 mg/dL. As it was suspected that the reduced renal blood flow was caused by progression of aortic dissection, contrast-enhanced computed tomography (CT)was performed. The left kidney showed reduced enhancement and the right kidney was heterogeneously enhanced. The dissection had extended to the left renal artery, and the reduced renal blood flow caused by narrowing of the left renal artery was thought to have caused the renal dysfunction. As elevated urea nitrogen and serum creatinine levels and hyperkalemia persisted, hemodialysis was performed a total of four times. Although the patient was subsequently withdrawn from dialysis, he continued to display severe renal dysfunction and was transferred to our department on day 28 for the treatment of renal failure. Conservative treatment was continued, but the maximum diameter of the thoracic aorta gradually increased, and stent placement at the entry of aortic dissection was indicated. On day 86, two stent-grafts were placed for entries at the distal site of the descending aorta and the distal site of the aortic arch. Postoperative abdominal contrast-enhanced CT showed expansion of the true lumen, and blood flow and contrast enhancement improved in both kidneys. Postoperatively, serum creatinine gradually decreased, improving to 1.16 mg/dL on day 96. Renography in the third month after stent-graft placement showed improved renal function in both kidneys. These findings suggest that even at approximately 2 months after the onset of acute renal failure associated with aortic dissection, renal function can be improved by restoring blood flow in the renal arteries.

  10. Endovascular treatment of thoracic aortic pseudoaneurysm due to brucellosis: a rare case report.

    Science.gov (United States)

    Wang, Shuai; Wang, Qi; Liu, Han; Sun, Siqiao; Sun, Xiwei; Zhang, Yang; Wang, Zhongying; Cheng, Zhihua

    2017-06-02

    Arterial damage is a known complication of brucellosis, but the occurrence of a thoracic aortic pseudoaneurysm secondary to brucellosis has not been previously reported. A 65-year-old Chinese man presented with a pseudoaneurysm in the descending segment of the thoracic aorta that caused symptoms of chest pain and intermittent fever. He was diagnosed with a thoracic aortic pseudoaneurysm secondary to brucellosis based on a positive brucella serology test (standard-tube agglutination test) and imaging examination (computed tomography angiography). Anti-brucellosis treatment and covered stent graft implantation were attempted to eliminate the brucellosis and pseudoaneurysm, respectively, and were ultimately successful, with no symptoms after 6 months of follow-up. Endovascular repair may be effective and safe for treating a thoracic aortic pseudoaneurysm resulting from brucellosis.

  11. Tailored endovascular repair of traumatic aortic disruptions with "stacked" abdominal aortic extension cuffs.

    Science.gov (United States)

    Allen, Keith B; Borkon, A Michael; Laster, Steven B; Aggarwal, Sanjeev; Davis, John R; Pak, Alexander F; Stewart, James R; Stuart, R Scott

    2012-01-01

    The management paradigm for traumatic aortic disruptions has evolved from open to endovascular repair. Thoracic stent grafts designed to treat aneurysmal disease, however, have disadvantages, including size mismatch in younger trauma patients and current standard lengths, which may needlessly necessitate coverage of at least 10 cm of thoracic aorta, increasing the risk of spinal cord ischemia. The "off-label" use of abdominal aortic extension cuffs to treat traumatic aortic disruptions may provide an advantage in this regard by better size matching for the younger trauma patient, reduced thoracic aortic coverage, and less cost to the institution. From 2008 to 2011, a total of 16 traumatic aortic disruptions were evaluated and managed with endovascular techniques. The last six were treated with abdominal aortic extensions cuffs (Excluder Extension Cuffs; W.L. Gore & Associates, Flagstaff, AZ) rather than traditional thoracic stent grafts. In addition to demographics and trauma-related data, additional endpoints evaluated in this retrospective review included operative time, number of cuffs used, stent cost data, procedural complications, and follow-up. All six patients (five men/one woman) with traumatic aortic disruption were successfully treated with complete exclusion of the disruption using abdominal aortic cuffs. There were no complications including death or spinal cord ischemia. The average age was 27 years (range, 18-44 years). The average number of cuffs used to cover the traumatic tear was 2.6 per patient (range, 2-3 cuffs per patient), covering an average of 5.3 cm of thoracic aorta (range, 4-6 cm). Mean procedure time was 70 minutes. Hospital cost for each cuff was $2200 (average total stent cost per patient, $5720). For comparison, a single 10-cm conformable thoracic aortic graft (CTAG) (Gore) costs $14,500. Average follow-up of all six patients for up to 3 years demonstrates no complications or migration of the stent grafts. Traumatic aortic

  12. Endovascular Treatment of Anastomotic Pseudoaneurysms after Aorto-iliac Surgical Reconstruction

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Recaldini, Chiara; Lumia, Domenico; Cuffari, Salvatore; Caronno, Roberto; Castelli, Patrizio; Fugazzola, Carlo

    2007-01-01

    Purpose. To assess the effectiveness of endovascular treatment of anastomotic pseudoaneurysms (APAs) following aorto-iliac surgical reconstruction. Materials. We retrospectively evaluated 21 men who, between July 2000 and March 2006, were observed with 30 APAs, 13 to the proximal anastomosis and 17 to the distal anastomosis. The patients had had previous aorto-iliac reconstructive surgery with a bypass due to aneurysm (15/21) or obstructive disease (6/21). The following devices were used: 12 bifurcated endoprostheses, 2 aorto-monoiliac, 4 aortic extenders, 1 stent-graft leg, and 2 covered stents. Follow-up was performed with CT angiography at 1, 3, and 6 months after the procedure and yearly thereafter. Results. Immediate technical success was 100%. No periprocedural complications occurred. Four patients died during follow-up from causes not related to APA, and 1 (treated for prosthetic-enteric fistula) from sepsis 3 months after the procedure. During a mean follow-up of 19.7 months (range 1-72 months), 2 of 21 occlusions of stent-graft legs occurred 3 and 24 months after the procedure (treated with thrombolysis and percutaneous transluminal angioplasty and femorofemoral bypass, respectively) and 1 type I endoleak. Primary clinical success rate was 81% and secondary clinical success was 91%. Conclusion. Endovascular treatment is a valid alternative to open surgery and can be proposed as the treatment of choice for APAs, especially in patients who are a high surgical risk. Further studies with larger series and longer follow-up are necessary to confirm the long-term effectiveness of this approach

  13. Tratamento endovascular de dissecção crônica toracoabdominal complicada com aneurisma torácico, mediante implante de endoprótese vascular

    Directory of Open Access Journals (Sweden)

    Gaudencio Espinosa

    Full Text Available Our objective is to report a case of a patient with a descending thoracic aortic aneurysm and chronic aortic dissection, who was submitted to an endovascular treatment. A 68-year-old male with coronary artery disease and hypertension, with no history of trauma, diabetes or smoking. He had myocardial infarction ten years ago. Under general anesthesia, the left femoral artery was surgically exposed and the left braquial artery was catheterized with a "pigtail" catheter, under Seldinger technique. The proximal 46mm/Æ and distal 34mm/Æ stent-graft was placed just distal to the origen of the left subclavian artery. Control arteriography showed that the lesion was completely excluded. The patient was discharged seven days after the surgery, when a computed tomographic control, was performed showing a sustained aneurysm exclusion and a satisfactory endovascular position.

  14. Increasing endovascular intervention for claudication: impact on vascular surgery resident training.

    Science.gov (United States)

    Keeling, W Brent; Stone, Patrick A; Armstrong, Paul A; Kearney, Heather; Klepczyk, Lisa; Blazick, Elizabeth; Back, Martin R; Johnson, Brad L; Bandyk, Dennis F; Shames, Murray L

    2006-08-01

    To audit the caseloads of vascular surgery residents in the management of disabling claudication and assess the influence of endovascular procedures on overall operative experience. A retrospective review was conducted of vascular surgery resident experience in the open and endovascular management of lower limb claudication during two 3-year periods (January 2000 to December 2002 and January 2003 to December 2005). The time periods differed with regard to number of surgical faculty with advanced endovascular skills (3 in the first period and 4 in the second) and the availability of portable operating room angiography equipment. During the 6-year period, the operative logs of vascular surgery residents indicated participation in 283 procedures [170 (60%) open surgical interventions, including 146 suprainguinal procedures] performed for claudication. The number of procedures increased by 62% (pocclusive disease increased 4-fold (14 versus 56 interventions, p=0.01) compared to a decrease in open (bypass grafting, endarterectomy) surgical repair (45 to 31 procedures, p=0.22). The greatest change in resident experience was in endovascular intervention of infrainguinal occlusive disease: the case volume increased from 4 to 39 procedures (p=0.07) during the 2 time intervals. By contrast, the number of open surgical bypass procedures was similar (45 versus 49) in each 3-year period. An audit of resident experience demonstrated intervention for claudication has increased during the past 6 years. The increased operative experience reflects more endovascular treatment (atherectomy, angioplasty, stent-graft placement) of femoropopliteal and aortoiliac occlusive disease, but no decrease in open surgical operative experience for claudication. This increase in endovascular intervention may be related to a decrease in the threshold for intervention.

  15. Endovascular repair of early rupture of Dacron aortic graft--two case reports.

    LENUS (Irish Health Repository)

    Sultan, Sherif

    2005-01-01

    Complications after open aortic surgery pose a challenge both to the vascular surgeon and the patient because of aging population, widespread use of cardiac revascularization, and improved survival after aortic surgery. The perioperative mortality rate for redo elective aortic surgery ranges from 5% to 29% and increases to 70-100% in emergency situation. Endovascular treatment of the postaortic open surgery (PAOS) patient has fewer complications and a lower mortality rate in comparison with redo open surgical repair. Two cases of ruptured abdominal aortic aneurysm (AAA) were managed with the conventional open surgical repair. Subsequently, spiral contrast computer tomography scans showed reperfusion of the AAA sac remnant mimicking a type III endoleak. These graft-related complications presented as vascular emergencies, and in both cases endovascular aneurysm repair (EVAR) procedure was performed successfully by aortouniiliac (AUI) stent graft and femorofemoral crossover bypass. These 2 patients add further merit to the cases reported in the English literature. This highlights the crucial importance of endovascular grafts in the management of such complex vascular problems.

  16. Simultaneous endovascular repair of an iatrogenic carotid-jugular fistula and a large iliocaval fistula presenting with multiorgan failure: a case report

    Directory of Open Access Journals (Sweden)

    Yuminaga Yuigi

    2012-01-01

    Full Text Available Abstract Introduction Iliocaval fistulas can complicate an iliac artery aneurysm. The clinical presentation is classically a triad of hypotension, a pulsatile mass and heart failure. In this instance, following presentation with multiorgan failure, management included the immediate use of an endovascular stent graft on discovery of the fistula. Case presentation A 62-year-old Caucasian man presented to our tertiary hospital for management of iatrogenic trauma due to the insertion of a central venous line into his right common carotid artery, causing transient ischemic attack. Our patient presented to a peripheral hospital with fever, nausea, vomiting, acute renal failure, acute hepatic dysfunction and congestive heart failure. A provisional diagnosis of sepsis of unknown origin was made. There was a 6.5 cm×6.5 cm right iliac artery aneurysm present on a non-contrast computed tomography scan. An unexpected intra-operative diagnosis of an iliocaval fistula was made following the successful angiographic removal of the central line to his right common carotid artery. Closure of the iliocaval fistula and repair of the iliac aneurysm using a three-piece endovascular aortic stent graft was then undertaken as part of the same procedure. This was an unexpected presentation of an iliocaval fistula. Conclusion Our case demonstrates that endovascular repair of a large iliac artery aneurysm associated with a caval fistula is safe and effective and can be performed at the time of the diagnostic angiography. The presentation of an iliocaval fistula in this case was unusual which made the diagnosis difficult and unexpected at the time of surgery. The benefit of immediate repair, despite hemodynamic instability during anesthesia, is clear. Our patient had two coronary angiograms through his right femoral artery decades ago. Unusual iatrogenic causes of iliocaval fistulas secondary to previous coronary angiograms with wire and/or catheter manipulation should be

  17. 3D printing of an aortic aneurysm to facilitate decision making and device selection for endovascular aneurysm repair in complex neck anatomy.

    Science.gov (United States)

    Tam, Matthew D B S; Laycock, Stephen D; Brown, James R I; Jakeways, Matthew

    2013-12-01

    To describe rapid prototyping or 3-dimensional (3D) printing of aneurysms with complex neck anatomy to facilitate endovascular aneurysm repair (EVAR). A 75-year-old man had a 6.6-cm infrarenal aortic aneurysm that appeared on computed tomographic angiography to have a sharp neck angulation of ~90°. However, although the computed tomography (CT) data were analyzed using centerline of flow, the true neck length and relations of the ostial origins were difficult to determine. No multidisciplinary consensus could be reached as to which stent-graft to use owing to these borderline features of the neck anatomy. Based on past experience with rapid prototyping technology, a decision was taken to print a model of the aneurysm to aid in visualization of the neck anatomy. The CT data were segmented, processed, and converted into a stereolithographic format representing the lumen as a 3D volume, from which a full-sized replica was printed within 24 hours. The model demonstrated that the neck was adequate for stent-graft repair using the Aorfix device. Rapid prototyping of aortic aneurysms is feasible and can aid decision making and device delivery. Further work is required to test the value of 3D replicas in planning procedures and their impact on procedure time, radiation dose, and procedure cost.

  18. Concepts to optimize stent-grafting of abdominal aortic aneurysms based on results of experimental studies; Konzepte zur Optimierung der Stentgraftversorgung von Bauchaortenaneurysmen auf der Basis tierexperimenteller Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Chavan, A.; Kirchhoff, T.; Baus, S.; Galanski, M. [Medizinische Hochschule Hannover (Germany). Abt. Diagnostische Radiologie 1; Pichlmaier, M. [Medizinische Hochschule Hannover (Germany). Leibniz Forschungslab. fuer Biotechnologie und Kuenstliche Organe an der Klinik fuer Thorax-, Herz- und Gefaesschirurgie

    2001-08-01

    Purpose. In the endoluminal therapy of abdominal aortic aneurysms, a short proximal aneurysm neck, endoleaks and the large size and stiffness of the introducer systems are responsible for many of the complications and sub-optimal outcomes. The purpose of the present review article is to to suggest strategies to minimize these complications based on the results of experimental studies in animals. Material and methods. After implanting various types of stents across the renal artery origins, the functional and morphological changes in the kidneys and renal vessels were studied by various authors. In order to prevent progressive widening of the proximal aneurysmal neck and graft dislocation, Sonesson et al. performed a laparoscopic banding around the proximal neck in pigs. To study the effects of endoleaks, Marty, Schurink and Pitton carried out pressure measurements in experimental aneurysms with and without endoleaks. Sakaguchi and Pavcnik developed the 'Twin-tube endografts' (TTEG) and the 'Bifurcated drum occluder endografts' (BDOEG) and tested them in dogs. Results. Up to 3 months after suprarenal stent placement, Chavan et al. detected no significant fall in the mean inulin clearance in sheep (140{+-}46 ml/min before, 137{+-}58 ml/min after). Nasim et al. and Malina et al. reported similar observations with respect to renal function. Suprarenal fixation may result in isolated thrombotic occlusions of the renal arteries and microinfarcts in the kidneys. Mean aortic diameters at the level of banding were significantly smaller in the animals with aortic banding as opposed to those in the control group without banding (8 mm vs 11 mm, p=0.004). The banding caused a secure proximal fixation of the stent-graft. Persistent endoleaks resulted in significantly higher intraaneurysmal pressures. Although the TTEG and the BDOEG stent-grafts required smaller sheaths, occlusions were observed in 8% (TTEG) and 60% (BDOEG) of the graft limbs. (orig.) [German

  19. Selective coverage of the left subclavian artery without revascularization in patients with bilateral patent vertebrobasilar junctions during thoracic endovascular aortic repair.

    Science.gov (United States)

    Lee, Minwook; Lee, Do Yun; Kim, Man-Deuk; Won, Jong Yun; Yune, Young-Nam; Lee, Taek Yeon; Choi, Donghoon; Ko, Young-Guk

    2013-05-01

    The primary purpose of the current study was to evaluate the safety and effectiveness of selective coverage of the left subclavian artery (LSCA) without revascularization during thoracic endovascular aortic repair (TEVAR) in patients with bilateral patent vertebrobasilar junctions. The secondary purpose was to assess morphologic change of the vertebral artery (VA) after the procedure. Among 126 patients who underwent TEVAR between 2006 and 2011, 29 patients requiring LSCA coverage without preemptive revascularization were retrospectively analyzed in this study. The patients were a mean age of 63.1 years (range, 45-84 years). The mean follow-up period was 19.9 months (range, 1-63 months). Bilateral patent vertebrobasilar junctions were evaluated by contrast-enhanced computed tomography (CT), time-of flight magnetic resonance angiography, or conventional angiography. Neurologic complications, such as spinal cord ischemia (SCI) or cerebrovascular accidents, were analyzed. Preprocedural and postprocedural changes in VAs were evaluated on follow-up contrast-enhanced CT. The overall 30-day mortality was 6.9% (2 of 29). None of the patients had SCI or a stroke of posterior circulation alone. Cerebrovascular accidents from embolic infarctions occurred in two patients (7.4%). Transient left arm ischemic symptoms were present in five patients (18.5%), but none required secondary interventions. Delayed development of type I endoleak occurred due to stent deformity in one patient, who underwent surgery. One patient required reintervention after the 10-month follow-up contrast-enhanced CT showed a pseudoaneurysm had developed at the distal margin of the previously placed stent graft. Hypertrophy of the right VA after TEVAR was seen in seven of 27 patients (25.9%); two patients showed bilateral hypertrophy of VAs. LSCA coverage without revascularization can be safely performed during TEVAR in patients with bilateral patent vertebrobasilar junctions. Hypertrophy of the right VA

  20. Surgeon Modified Fenestrated Endovascular Abdominal Aortic Repair (F-EVAR for Subacute Multifocal Mycotic Abdominal and Iliac Artery Saccular Aneurysms

    Directory of Open Access Journals (Sweden)

    J.A. Sule

    Full Text Available Introduction: Endovascular repair of suprarenal abdominal aortic aneurysms (AAAs requires customized fenestrated stent grafts when they involve visceral vessels such as the renal (clinically ignored here in this specific scenario, celiac, and superior mesenteric arteries. Report: On table fenestrated endovascular abdominal aortic aneurysm repair (F-EVAR, using a parallel endograft approach, was performed for enlarging saccular subacute mycotic suprarenal and left common iliac artery aneurysms in a 58 year old man with recent methicillin sensitive Staphylococcus aureus (MSSA bacteremia, who was high risk for open surgical repair. Fenestrations were performed for the coeliac artery (CA and superior mesenteric artery (SMA using a Bovie® (Clearwater, FL, USA cautery device. The initial procedure was complicated by a type II endoleak that resolved spontaneously within 6 months of surgery. The patient remained well on follow up a year post surgery. Conclusion: On table surgeon modified F-EVAR is a safe and viable option for patients with subacute suprarenal mycotic abdominal aneurysms. Keywords: Aneurysm, Endovascular, Aortic, Mycotic, Surgeon modified, Fenestrated

  1. Mortality within the endovascular treatment in Stanford type B aortic dissections Mortalidade no tratamento endovascular nas dissecções aórticas tipo B

    Directory of Open Access Journals (Sweden)

    Alexandre Fioranelli

    2011-06-01

    Full Text Available BACKGROUND: Endovascular stent-graft repair of aortic dissections is a relatively new procedure, and although apparently less invasive, the efficacy and safety of this technique have not been fully established. OBJECTIVE: To evaluate mortality in patients with complicated Stanford type B aortic dissections submitted to endovascular treatment. METHODS: Clinical, anatomical, imaging and autopsy data of 23 patients with complicated type B aortic dissections were reviewed from November 2004 to October 2007. The main indications for transluminal thoracic stent-grafting included: persistent pain in spite of medical therapy, signs of distal limb ischemia, signs of aortic rupture, progression of aneurismal dilation of the descending aorta during follow-up (defined as a diameter > 50 mm and the diameter of descending thoracic aorta of 40mm or larger at the onset of aortic dissection. Data were analyzed statistically; all p-values were two-tailed and differences INTRODUÇÃO: O tratamento endovascular na dissecção de aorta é um procedimento relativamente novo e, embora aparentemente menos invasivo, a eficácia e a segurança dessa técnica não estão totalmente estabelecidas. OBJETIVO: Avaliar a mortalidade e complicações nos pacientes submetidos a tratamento endovascular na dissecção de aorta tipo B de Stanford. MÉTODOS: Foram revisados, a partir de novembro de 2004 a outubro de 2007, em estudo clínico, anatômico, de imagens e dados da autopsia de 23 pacientes com dissecção aórtica tipo B. As principais indicações para o procedimento foram: dor persistente apesar da terapia médica, sinais de isquemia distal do membro, sinais de ruptura da aorta, progressão da dilatação do aneurisma da aorta descendente, durante o seguimento (definida como um diâmetro > 5 cm e descendente da aorta torácica de 40 mm ou mais de diâmetro no início da dissecção aórtica. Os dados foram analisados estatisticamente considerados erro alfa de 5%. As vari

  2. Estudo da resposta tissular à endoprótese recoberta de jugular bovina em veia cava inferior de suínos Bovine jugular covered stent-graft implanted in swine inferior vena cava - a study of tissue response

    Directory of Open Access Journals (Sweden)

    Cristina Ribeiro Riguetti Pinto

    2006-06-01

    aortic stent-graft deployment (Florida, USA. Ten handmade stent-grafts were implanted in 10 swine inferior venae cavae. All animals were submitted to perioperative venography. At necropsy, 2 months later, the stent-grafts were removed en bloc and histopathologic analysis was undertaken, in order to analyze its patency, adherence to neighboring tissues and incorporation to the venous wall, as well as tissue response. RESULTS: All stent-grafts were patent and adherent to venous wall, but six presented with gross trabeculation and four had some degree of perivascular fibrosis at macroscopy. Three animals developed lymphocele, one in the retroperitoneal space and the others in the abdominal wall. At histopathology, we observed chronic inflammatory reaction with foreign body granulomatous response in all cases, with prevalence of the tunica media (80%. CONCLUSION: The model presented low thrombogenicity, which corroborates the efficacy of the chosen means of preservation and material. However, there was low compatibility, probably due to the immunological obstacle of xenografts and exaggerated tissue response of the venous territory.

  3. Technical and clinical success after endovascular therapy for chronic type B aortic dissections.

    Science.gov (United States)

    Oberhuber, Alexander; Winkle, Philipp; Schelzig, Hubert; Orend, Karl-Heinz; Muehling, Bernd Manfred

    2011-11-01

    To analyze early technical success and late clinical success after endovascular entry sealing for chronic type B dissection with special emphasis on reintervention, false lumen thrombosis, and aortic remodeling. Retrospective analysis of a prospective database. From September 1999 to January 2011, 19 patients with chronic type B dissections were treated by endovascular entry sealing. Median age was 60 years. Median time between onset of acute dissection and surgical intervention was 36 (1 to 60) months. Median follow-up was 13 months (1 to 124). The endografts used were: Medtronic Captivia (5), Medtronic Valiant (5), Gore TAG (6), Gore C-TAG (2), and Cook Zenith (1). In four patients, revascularization of the left subclavian artery was performed prior to entry sealing. Primary technical success rate (entry sealing, absence of type I leak) was 18/19 (94.7%). In-hospital mortality was 0%. Spinal cord injury with persistent paraplegia occurred in 1/19 (5.2%) patients. After a maximal follow-up of 124 months, reinterventions in 9/19 (47.3%) were necessary: distal/proximal extension of stent graft (8), replacement of the aortic arch due to retrograde dissection (1), and open infrarenal aneurysm repair (1). During follow-up, none of the patients died due to stent-related complications. Endovascular treatment (EVT) in chronic type B dissections has a high technical success rate and low mortality/morbidity. However reintervention rates are not negligible which might reduce the clinical success of EVT. Future investigations should aim at identifying patients who benefit from EVT at better defining the timing of EVT and at determining if entry sealing alone is sufficient. Copyright © 2011 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  4. Use of the Nellix Endovascular Aneurysm Sealing System in Combination With Parallel Grafts for the Treatment of a Symptomatic Type V Thoracoabdominal Aortic Aneurysm.

    Science.gov (United States)

    Klonaris, Chris; Katsargyris, Athanasios; Athanasiadis, Dimitris; Liakakos, Theodor

    2017-12-01

    To report endovascular treatment of a symptomatic type V thoracoabdominal aortic aneurysm (TAAA) using the combined techniques of endovascular aneurysm sealing and parallel stent-grafts. A 70-year-old man was referred with a symptomatic type V TAAA. The Nellix EndoVascular Aneurysm Sealing (EVAS) System was used in combination with 2 chimney grafts for the celiac artery (CA) and the superior mesenteric artery (SMA); one periscope graft perfused the right renal artery. Completion angiography showed exclusion of the aneurysm and patency of all 3 parallel grafts but occlusion of the left renal artery (LRA) due to unintentional coverage of its ostium by the Nellix endobags. Antegrade catheterization of the LRA failed, requiring implantation of an aortorenal vein bypass. The postoperative course was complicated by acute kidney injury. Imaging at 6 months showed sustained exclusion of the aneurysm, patency of the CA and SMA parallel grafts and left aortorenal bypass but occlusion of the right renal artery periscope graft. Serum creatinine at 6 months was 1.5 mg/dL. The combination of EVAS with parallel grafts for preservation of the visceral vessels may be a feasible technique to treat selected TAAAs in the acute setting when other options are not applicable.

  5. Endovascular treatment of aneurysms of the popliteal artery by a covered endoprosthesis.

    Science.gov (United States)

    Wissgott, Christian; Lüdtke, Christopher W; Vieweg, Hendryk; Scheer, Fabian; Lichtenberg, Michael; Schlöricke, Erik; Andresen, Reimer

    2014-01-01

    The current gold standard of popliteal artery aneurysm (PAA) treatment is saphenous vein bypass grafting. The aim of this retrospective single-center study is to investigate the safety and efficacy in the treatment of PAA by an endovascular implanted covered endoprosthesis. Ten patients, mean age 64.6 (range, 52-78) years, with PAA were treated with an expanded Polytetrafluoroethylen (ePTFE)-covered stent graft (Viabahn(®), W.L. Gore and Associates Inc, Flagstaff, AZ, USA). In median, 1.4 prostheses were implanted with a median length of 180 mm. Follow-up visits included determination of ankle-brachial index (ABI) and color-coded duplex sonography. The technical success rate was 100% (10/10). Clinically, there was an increase in ABI from 0.62 ± 0.17 to 0.91 ± 0.15 postinterventionally and to 0.89 ± 0.16 after an average follow-up of 24.7 months. During the follow-up period, 2 (20%) stent occlusions occurred; both of them were treated with a bypass graft. The treatment of PAA with covered endoprosthesis is a safe and effective alternative to open surgical therapy, where open surgical therapy is contraindicated or patient refused open surgery.

  6. Endovascular repair of blunt popliteal arterial injuries

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Shan; Zhang, Xiquan; Chen, Zhong; Zhu, Wei; Pan, Xiaolin [Dept. of nterventional Vascular, The 148th Hospital of Chinese People' s Liberation Army, Zibo (China); Dong, Peng; Sun, Yequan [Dept. of Medical Imaging, Weifang Medical University, Weifang (China); Qi, Deming [Dept. of Medical Imaging, Qilu Medical University, Zibo (China)

    2016-09-15

    To evaluate the feasibility and effectiveness of endovascular repair for blunt popliteal arterial injuries. A retrospective analysis of seven patients with clinical suspicion of popliteal arterial injuries that were confirmed by arteriography was performed from September 2009 to July 2014. Clinical data included demographics, mechanism of injury, type of injury, location of injury, concomitant injuries, time of endovascular procedures, time interval from trauma to blood flow restoration, instrument utilized, and follow-up. All patients were male (mean age of 35.9 ± 10.3 years). The type of lesion involved intimal injury (n = 1), partial transection (n = 2), complete transection (n = 2), arteriovenous fistula (n = 1), and pseudoaneurysm (n = 1). All patients underwent endovascular repair of blunt popliteal arterial injuries. Technical success rate was 100%. Intimal injury was treated with a bare-metal stent. Pseudoaneurysm and popliteal artery transections were treated with bare-metal stents. Arteriovenous fistula was treated with bare-metal stent and coils. No perioperative death and procedure-related complication occurred. The average follow-up was 20.9 ± 2.3 months (range 18–24 months). One patient underwent intra-arterial thrombolysis due to stent thrombosis at 18 months after the procedure. All limbs were salvaged. Stent migration, deformation, or fracture was not found during the follow-up. Endovascular repair seems to be a viable approach for patients with blunt popliteal arterial injuries, especially on an emergency basis. Endovascular repair may be effective in the short-term. Further studies are required to evaluate the long-term efficacy of endovascular repair.

  7. Clinical Outcomes of Endovascular Aneurysm Repair with the Kilt Technique for Abdominal Aortic Aneurysms with Hostile Aneurysm Neck Anatomy: A Korean Multicenter Retrospective Study.

    Science.gov (United States)

    Jeon, Yong Sun; Cho, Young Kwon; Song, Myung Gyu; Seo, Tae-Seok; Kim, Jeong Ho; Song, Soon-Young; Lee, Sam Yeol

    2018-04-01

    We aimed to evaluate the clinical efficacy and short-term clinical outcomes of Kilt technique-based endovascular aneurysm repair (EVAR) with Seal ® stent-grafts for abdominal aortic aneurysms (AAAs) with hostile neck anatomy (angle > 60°). We retrospectively evaluated the pre-EVAR and follow-up computed tomography angiography findings of 24 patients (mean age 71 ± 11 years; age range 32-87 years; mean follow-up 50 ± 12 months) with hostile neck AAAs treated between 2010 and 2015. Serial change in aneurysmal neck angle was calculated using a standardized protocol. Relationships between clinical variables and outcomes were evaluated using univariate and multivariate Cox analyses and mixed-model regression. In addition, the Kaplan-Meier method was used to assess the cumulative rates of survival, endoleak, and reintervention. The primary technical success rate (success within 24 h after EVAR) was 100% (24/24). The survival rate was 96 ± 8% at 1 month, 6 months, 1 year, and 3 years, and 87 ± 18% at 5 years. Endoleaks occurred in three patients. Four reinterventions were performed in three patients; no surgical revisions were required. Causes of post-EVAR mortality included intracerebral hemorrhage at 14 days and rhabdomyolysis at 32 months. The most remarkable change after Kilt-based EVAR was an acute decrease in the neck angle, which was observed between the pre-EVAR and first follow-up visits (at 1 month) (P = 0.001). Kilt-based EVAR with Seal ® stent-grafts for AAAs with a severely angulated neck (angle > 60°) provided high technical success, low mortality, and low complication rates during short-term follow-up.

  8. Endovascular obliteration of a ruptured posterior spinal artery pseudoaneurysm.

    Science.gov (United States)

    Tanweer, Omar; Woldenberg, Rona; Zwany, Sarah; Setton, Avi

    2012-10-01

    Aneurysms of the posterior spinal artery (PSA) are rare lesions. Isolated PSA aneurysms, not in the setting of a high-flow environment, are even more rare. In the few reported cases, these lesions have been predominantly resected or observed. The authors report an isolated pseudoaneurysm of the PSA at the T-11 level presenting with subarachnoid hemorrhage. The patient underwent successful endovascular obliteration. To the authors' knowledge, this is the first report of an endovascular repair of an isolated PSA aneurysm.

  9. [Outcomes of endovascular repairing aortic arch disease hybrid with supra-arch debranching procedures].

    Science.gov (United States)

    Wang, Mian; Chang, Guangqi; Yin, Henghui; Yao, Chen; Wang, Jinsong; Wang, Shenming

    2015-11-01

    To summarize the experience of endovascular repairing aortic arch disease hybrid with supra-arch debranching procedures. It was a retrospective study. From January 2002 to December 2014, 42 high risk patients with aortic arch disease were treated by supra-arch debranching hybrid with subsequent endovascular repair in the First Affiliated Hospital of Sun Yat-sen University. There were 39 male and 3 female patients with a mean age of (53±13) years (ranging from 34 to 80 years). Of the 42 patients, 7 were thoracic aortic aneurysm, 20 were Stanford type B aortic dissection and 15 were Stanford type A aortic dissection. After the supra-aortic debranching technique, simultaneous (n=16) or staged (n=26, mean interval (7±3) days) endovascular repair were performed. Fisher exact test was used to compare the in-hospital mortality of ascending aorta based debranching and non-ascending aorta based debranching. Technical success rate was 81.0% (34/42). The overall 30-day complication rate was 31.0% (13/42), including 3 cerebral stroke (7.1%), 8 endoleak (19.0%, including 6 type I endoleak and 2 type II endoleak), 1 circulatory failure, 1 aorto-tracheal fistula. The 30-day mortality was 9.5% (4/42), 2 died of cerebral stroke, 1 died of circulatory failure, 1 died of aorto-tracheal fistula. The in-hospital mortality of ascending aorta based debranching group was obviously higher than that of the non-ascending aorta based debranching group (4/16 vs. 0, P=0.02). The median time of follow-up was 64.8 (2 to 156.9) months. CT scanning was performed at 1, 3 months after surgery and annually thereafter. The overall survival rate was 76.6%. During the follow-up period, there was 4 deaths, and 2 of them were aortic artery related (5.3%). There were 4 de novo complications during the follow-up period, 1 stroke attributed to bypass occlusion was cured by medical treatment, 2 pseudoaneurysm was successfully treated with open surgery, 1 stent-graft induced new distal entry tear was

  10. Endovascular management of pancreatitis-related pseudoaneurysms: A review of techniques.

    Directory of Open Access Journals (Sweden)

    Bartosz Zabicki

    Full Text Available To present the various techniques used in the management of pancreatitis-related pseudoaneurysms of visceral vessels.The retrospective clinical study was carried out at the Department of Diagnostic and Interventional Radiology at Poznan University of Medical Sciences from 2011 to 2016. The fifteen patients included in the study were diagnosed with pseudoaneurysms of visceral arteries, as a complication of chronic pancreatitis. The diagnosis was made using contrast-enhanced computed tomography, followed by angiography. On admission, all patients were symptomatic, with varying degrees of abdominal pain. One patient was haemodynamically unstable. Treatments with endovascular techniques were analysed, along with their efficacy and outcomes. Coil embolisation was performed in 5 patients. Stent graft was used in 1 patient. Liquid embolic agents were used in 7 cases, of which 5 patients were treated with thrombin injection and 2 with Squid. A combination of techniques was used in 2 patients.The most common artery affected by pseudoaneurysm formation was the splenic artery (7/15; 46.7%, and the size of the pseudoaneurysms ranged from 27 mm to 85 mm. Primary technical success was achieved in 14 out of 15 patients (93.3%. One patient required reintervention. Two patients required splenectomy after embolisation due to splenic ischemia. No recanalisation was present at the follow-up computed tomography performed after 1 to 3 weeks, and no mortality was observed within 30 days.Vascular complications of pancreatitis require accurate diagnosis and immediate treatment. Endovascular intervention is highly effective and is the preferred treatment option. The technique used is determined based on vascular anatomy and the patient's haemodynamic status.

  11. Five-year outcomes of the PYTHAGORAS U.S. clinical trial of the Aorfix endograft for endovascular aneurysm repair in patients with highly angulated aortic necks.

    Science.gov (United States)

    Malas, Mahmoud B; Hicks, Caitlin W; Jordan, William D; Hodgson, Kim J; Mills, Joseph L; Makaroun, Michel S; Belkin, Michael; Fillinger, Mark F

    2017-06-01

    Early and midterm outcomes of the Prospective Aneurysm Trial: High Angle Aorfix Bifurcated Stent Graft (PYTHAGORAS) trial in patients with highly angulated aortic necks (≥60 degrees) have already been published and shown comparable outcomes to other endografts in normal anatomy. Herein, we present the long-term outcomes of the PYTHAGORAS trial of Aorfix (Lombard Medical, Irvine, Calif) for patients with highly angulated aortic neck anatomy. The Aorfix endograft is a highly conformable nitinol/polyester device designed for transrenal fixation. The U.S. trial enrolled 218 patients and observed all patients at 1 month, 6 months, and 12 months and then annually for a total of 5 years. Endovascular aneurysm repair (EVAR)-specific complications were compared between the standard-angle (PYTHAGORAS trial of the Aorfix endograft is the first EVAR clinical trial to include a majority of highly angulated (≥60 degrees) infrarenal aortic necks and is the first to produce evidence after 5 years of implantation. Despite predictors of worse short- and long-term outcomes, pertinent outcomes were better than or similar to those of trials with less severe anatomy. These results support the use of this "on-label" endovascular option, particularly in patients with highly angulated aortic neck anatomy. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  12. Tratamento endovascular de aneurismas cirsoideos do couro cabeludo Endovascular treatment of scalp cirsoid aneurysms

    Directory of Open Access Journals (Sweden)

    Eduardo Wajnberg

    2010-08-01

    Full Text Available OBJETIVO: Relatar os resultados da aplicação de técnicas endovasculares no tratamento de aneurismas cirsoideos do couro cabeludo. MATERIAIS E MÉTODOS: Quatro pacientes com diagnóstico de aneurismas cirsoideos foram submetidos ao tratamento por via endovascular. Todos os quatro pacientes incluídos nesta série tinham malformações arteriovenosas e foram tratados apenas com embolização. RESULTADOS: Três pacientes foram submetidos a tratamento endovascular mediante embolização transarterial e um foi tratado por punção direta da porção venosa. Os resultados clínicos e cosméticos foram satisfatórios em todos os pacientes. Não houve recidiva clínica durante o período de acompanhamento. CONCLUSÃO: A via endovascular é uma alternativa segura e eficaz no tratamento dos aneurismas cirsoideos. Embora possa ser efetivamente utilizado como uma alternativa adjuvante ou complementar à cirurgia, especialmente quando é necessário lidar com aferências profundas, a maioria dos casos pode ser totalmente curada apenas com a terapêutica endovascular. A escolha do método de tratamento deve ser baseada em uma variedade de características próprias da lesão, incluindo sua angioarquitetura, tamanho e apresentação clínica.OBJECTIVE: To report results of the application of endovascular techniques in the management of scalp cirsoid aneurysms. MATERIALS AND METHODS: Four patients diagnosed with cirsoid aneurysms were submitted to treatment by endovascular approach. All the four patients included in the present series had arteriovenous malformations and were treated solely by embolization. RESULTS: Three of the patients underwent endovascular treatment by transarterial embolization and one was treated by direct puncture of the venous segment. Both clinical and cosmetic outcomes were satisfactory in all of the patients. Clinical relapse was not observed along the follow-up period. CONCLUSION: The endovascular approach is safe and effective in

  13. Midterm outcome of EndoAnchors for the prevention of endoleak and stent-graft migration in patients with challenging proximal aortic neck anatomy.

    Science.gov (United States)

    Jordan, William D; de Vries, Jean-Paul P M; Ouriel, Kenneth; Mehta, Manish; Varnagy, David; Moore, William M; Arko, Frank R; Joye, James; Henretta, John

    2015-04-01

    To explore the use of EndoAnchors as an adjunct to endovascular abdominal aortic aneurysm repair for prevention of proximal neck complications in patients with challenging neck anatomy. Over a 28-month period, 208 patients (159 men; mean age 72±8 years) were enrolled in the ANCHOR prospective, multicenter registry (ClinicalTrials.gov; identifier NCT01534819) for prophylaxis against proximal neck complications. Patients were eligible when, in the opinion of the investigators, they were at increased risk for type Ia endoleak or migration owing to a hostile neck (length 28 mm, angulation >60°, mural thrombus or calcium >2 mm in thickness or >180° in circumference, or conical shape). Overall, 123/157 (78.3%) patients met the criteria for a hostile neck according to core laboratory assessment of 157 adequate preoperative computed tomographic (CT) images. Implantation of EndoAnchors was technically successful in 204/208 (98.1%) patients. The frequency of fracture was 0.3% (3/1118); there were no clinical sequelae associated with the fractures. Over the mean 14-month follow-up, 95.2% of patients were alive, and no deaths were attributable to EndoAnchors. There were no ruptures, migrations, or open surgical conversions. Aneurysm-related reinterventions were performed in 8 (3.8%) patients. Among 130 patients with postprocedure contrast CT studies, core laboratory analysis identified 2 (1.5%) patients with type Ia endoleaks. Aneurysm sac diameter decreased >5 mm in 42.9% of patients with CT scans at or beyond 1 year; 1.6% of patients developed sac enlargement >5 mm. Prophylactic EndoAnchor use for challenging aortic neck anatomy was associated with satisfactory midterm results. © The Author(s) 2015.

  14. Endovascular therapy of abdominal aortic aneurysm: results of a mid-term follow-up

    International Nuclear Information System (INIS)

    Pitton, M.B.; Schweitzer, H.; Herber, S.; Thelen, M.; Schmiedt, W.; Neufang, A.; Dueber, C.

    2003-01-01

    Prospective study to evaluate clinical results and complications of endovascular abdominal aortic aneurysm treatment in a mid-term follow-up. Materials and methods: A total of 122 patients (9 females, 113 males, average age 70.0±7,9 years) with abdominal aortic aneurysms were treated with stent grafts (53 Vanguard or Stentor endografts, 69 Talent endografts). Group I consisted of 40 patients who had all aortic tributaries of the aneurysm sac occluded prior to endovalscular grafting, either spontaneously by parietal thrombosis or by selective coil embolization of the respective ostia preserving collateral circulation distal to the vessel occlusion. Group II consisted of 82 patients and included all cases without or with incomplete coil embolization with at least one patent vessel. Stent grafting was performed in general anesthesia in the first 21 patients, followed by peridural anesthesia in 15 cases, and local anesthesia with conscious sedation in 86 cases. The results were evaluated with Spiral-CT, MRI and radiographs of the endovascular graft, with follow-up examinations obtained at 3, 6, 12 months, and every year - Implantation was successfully completed in all cases without primary conversion surgery, laparotomy or any significant complication. Mean follow-up was 29±21 months (maximum 82 months). The 30-day mortality was 0,8% due to a myocardial infarction 3 days after discharge from the hospital. A total of 47 re-interventions were performed in 29 patients (23.8%), with 35 re-interventions in 18 cases with Vanguard or Stentor endografts and 12 re-interventions in 11 patients with Talent endografts. 23 percutaneous re-interventions included distal graft extension (n=11), Wallstent for kinking and limb stenosis (n=3), and secondary coil embolization of collateral vessels (n=9). 24 surgical re-interventions included proximal graft extension (n=6), new endovascular grafts (n=3), surgical clipping of lumbar and mesenteric artery branches for type-II endoleaks

  15. Graft Distortion After Endovascular Repair of Abdominal Aortic Aneurysm: Association with Sac Morphology and Mid-Term Complications

    International Nuclear Information System (INIS)

    Gould, Derek Alan; Edwards, Richard David; McWilliams, Richard Gregory; Rowlands, Peter Christopher; Martin, Janis; White, Donagh; Fear, Simon; Bakran, Ali; Brennan, John; Gilling-Smith, Geoffrey; Harris, Peter Lyon

    2000-01-01

    Purpose: To investigate the incidence, significance, and mechanism of stent-graft distortion after endovascular repair (EVR) of abdominal aortic aneurysm.Methods: EVR of abdominal aortic aneurysm was performed in 51 cases (49 modular, bifurcated; 2 tube). Thirty-two patients were followed for 6 or more months and had equivalent baseline and follow-up images which could be used to determine changes in graft configuration. Sac dimensions were measured using computed tomographic (CT) images and graft-related complications were recorded.Results: Amongst 32 patients evaluated on follow-up, there was graft distortion in 24. Distorted grafts were significantly (p= 0.002) associated with sac diameter reduction (mean 5 mm) and sac length reduction (mean 8.1 mm). All graft-related complications occurred in the limbs of eight distorted grafts, with a mean reduction of sac length in this group of 7.8 mm on reformatted CT images.Conclusion: There was a highly significant association between graft distortion and limb complications, and reduced sac dimensions

  16. Celiac Trunk Embolization, as a Means of Elongating Short Distal Descending Thoracic Aortic Aneurysm Necks, Prior to Endovascular Aortic Repair

    International Nuclear Information System (INIS)

    Belenky, Alexander; Haddad, Menashe; Idov, Igor; Knizhnik, Michael; Litvin, Sergey; Bachar, Gil N.; Atar, Eli

    2009-01-01

    The purpose of this study was to report our experience in elongating short distal necks of descending thoracic aortic aneurysms (DTAAs) by coil embolization of the celiac trunk prior to endovascular aneurysm repair (EVAR). During 6 years seven patients (five men and two women; mean age, 74) who had DTAAs with short distal necks unsuitable for conventional EVAR, and well patent superior and inferior mesenteric arteries based on CT, were treated in one session with EVAR after the celiac trunk was coil embolized to elongate the neck. All patients were followed by CT every 3 months in the first year and every 6 months thereafter. Technical success was achieved in all patients, and no early or late ischemic complications were noted. No procedural complications occurred and good aneurysm sealing was obtained in all patients. Three endoleaks were identified after 3 months (one patient) and 6 months (two patients); all were treated successfully with insertion of an additional stent-graft. In patients with DTAAs who are candidates for EVAR but have short aneurysm distal necks, celiac trunk embolization-only if the superior and inferior mesenteric arteries are patent-is a good and safe way to elongate the neck and enable EVAR.

  17. Intraoperative Sac Pressure Measurement During Endovascular Abdominal Aortic Aneurysm Repair

    International Nuclear Information System (INIS)

    Ishibashi, Hiroyuki; Ishiguchi, Tsuneo; Ohta, Takashi; Sugimoto, Ikuo; Iwata, Hirohide; Yamada, Tetsuya; Tadakoshi, Masao; Hida, Noriyuki; Orimoto, Yuki; Kamei, Seiji

    2010-01-01

    PurposeIntraoperative sac pressure was measured during endovascular abdominal aortic aneurysm repair (EVAR) to evaluate the clinical significance of sac pressure measurement.MethodsA microcatheter was placed in an aneurysm sac from the contralateral femoral artery, and sac pressure was measured during EVAR procedures in 47 patients. Aortic blood pressure was measured as a control by a catheter from the left brachial artery.ResultsThe systolic sac pressure index (SPI) was 0.87 ± 0.10 after main-body deployment, 0.63 ± 0.12 after leg deployment (P < 0.01), and 0.56 ± 0.12 after completion of the procedure (P < 0.01). Pulse pressure was 55 ± 21 mmHg, 23 ± 15 mmHg (P < 0.01), and 16 ± 12 mmHg (P < 0.01), respectively. SPI showed no significant differences between the Zenith and Excluder stent grafts (0.56 ± 0.13 vs. 0.54 ± 0.10, NS). Type I endoleak was found in seven patients (15%), and the SPI decreased from 0.62 ± 0.10 to 0.55 ± 0.10 (P = 0.10) after fixing procedures. Type II endoleak was found in 12 patients (26%) by completion angiography. The SPI showed no difference between type II endoleak positive and negative (0.58 ± 0.12 vs. 0.55 ± 0.12, NS). There were no significant differences between the final SPI of abdominal aortic aneurysms in which the diameter decreased in the follow-up and that of abdominal aortic aneurysms in which the diameter did not change (0.53 ± 0.12 vs. 0.57 ± 0.12, NS).ConclusionsSac pressure measurement was useful for instant hemodynamic evaluation of the EVAR procedure, especially in type I endoleaks. However, on the basis of this small study, the SPI cannot be used to reliably predict sac growth or regression.

  18. Disección de aorta: Aspectos básicos y manejo endovascular Aortic dissection: Basic aspects and endovascular management

    Directory of Open Access Journals (Sweden)

    Nicolás I Jaramillo

    2005-08-01

    Full Text Available El tratamiento de la patología aórtica torácica se complica por la asociación con una alta mortalidad en la reparación quirúrgica, y al mismo tiempo fragilidad y gran comorbilidad en los adultos de edad avanzada. En la búsqueda por reducir la incidencia de resultados negativos, en la década pasada se introdujo la técnica de intervención por la vía de la mínima invasión, con la colocación de dispositivos del tipo stent vía endovascular. La técnica, originalmente descrita por Parodi e inicialmente diseñada para uso en la corrección de aneurismas de aorta abdominal, ha sido adoptada para el uso en la patología aórtica torácica. El mejoramiento en el entendimiento de la fisiopatología y la historia natural de la enfermedad de la aorta torácica y el análisis de los resultados, han facilitado la toma de decisiones en cuanto al tratamiento en términos del tiempo de la intervención apropiada. El tratamiento de la disección de la aorta torácica con el uso de stent endovascular, es uno de los más recientes avances en el tratamiento y hoy recibe una atención especial, al punto que es una alternativa menos invasiva; incluso la tecnología está apenas en sus primeras etapas y en los últimos años se han mejorado significativamente el diseño y el sistema de liberación de estos dispositivos endovasculares conocidos como stent-grafts. Estas prótesis se utilizan de forma creciente en el tratamiento de aneurismas, disecciones, rupturas traumáticas, úlceras penetradas gigantes y hematomas intramurales de la aorta torácica descendente, con buenos resultados tanto tempranos como a mediano plazo. La poca frecuencia, la alta complejidad y la severidad de la patología, y al mismo tiempo el alto riesgo teórico de las complicaciones que se pueden generar, deben mantener cauto al operador, especialmente cuando esta técnica se aplica en pacientes jóvenes. De manera conceptual la solución por la vía endoluminal en las fases agudas

  19. Endovascular repair for blunt thoracic aortic injury: 11-year outcomes and postoperative surveillance experience.

    Science.gov (United States)

    Spiliotopoulos, Konstantinos; Kokotsakis, John; Argiriou, Michalis; Dedeilias, Panagiotis; Farsaris, Dimosthenis; Diamantis, Theodore; Charitos, Christos

    2014-12-01

    Surveillance for patients undergoing thoracic endovascular aortic repair (TEVAR) for blunt thoracic aortic injury (BTAI) varies. Annual chest computed tomographic angiography (CTA) is often recommended but concerns about the risks and costs have emerged. The aim of this study was to examine the optimal follow-up frequency based on 11-year outcomes and surveillance experience. Seventy-six patients with BTAI received TEVAR from May 2002 to July 2013. Demographics, cardiovascular risk factors, Injury Severity Score (ISS), types, sizes, timing, and outcomes of stent grafts were collected retrospectively. Mean age was 39.7 years (range, 17-85 years); 8 (11%) were women. Mean ISS was 46.2 ± 18.5 (deceased, 61.0 ± 19.2; surviving, 44.2 ± 17.6; P = .023). Technical success was achieved in 71 patients (93.4%). All-cause mortality was 7 (9.2%), 1 (1.3%) of which was related to the procedure. Six were lost to follow-up (8%). To examine the effect of surveillance frequency on outcomes, after excluding the 2 most recent (6 months after scheduled annual visit). No significant differences were found for survival, graft-related complications, need for reintervention, except for postoperative hypertension, which was higher in the first group. All surviving patients had excellent outcomes, with no cerebrovascular accidents, paraplegia, or paraparesis; the median follow-up for both groups was 3 years (interquartile range 2.0-3.5, 1.5-5.4 years). Midterm outcomes of TEVAR for patients with stable repair after BTAI are excellent, both with timely (1.0-1.5 years) and delayed (>1.5 years) follow-up intervals after a median surveillance period of 3 years. A larger prospective randomized study could lead to a more relaxed, but equally safe surveillance schedule for these patients, lowering risks and costs. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  20. The financial implications of endovascular aneurysm repair in the cost containment era.

    Science.gov (United States)

    Stone, David H; Horvath, Alexander J; Goodney, Philip P; Rzucidlo, Eva M; Nolan, Brian W; Walsh, Daniel B; Zwolak, Robert M; Powell, Richard J

    2014-02-01

    Endovascular aneurysm repair (EVAR) is associated with significant direct device costs. Such costs place EVAR at odds with efforts to constrain healthcare expenditures. This study examines the procedure-associated costs and operating margins associated with EVAR at a tertiary care academic medical center. All infrarenal EVARs performed from April 2011 to March 2012 were identified (n = 127). Among this cohort, 49 patients met standard commercial instruction for use guidelines, were treated using a single manufacturer device, and billed to Medicare diagnosis-related group (DRG) 238. Of these 49 patients, net technical operating margins (technical revenue minus technical cost) were calculated in conjunction with the hospital finance department. EVAR implant costs were determined for each procedure. DRG 238-associated costs and length of stay were benchmarked against other academic medical centers using University Health System Consortium 2012 data. Among the studied EVAR cohort (age 75, 82% male, mean length of stay, 1.7 days), mean technical costs totaled $31,672. Graft implants accounted for 52% of the allocated technical costs. Institutional overhead was 17% ($5495) of total technical costs. Net mean total technical EVAR-associated operating margins were -$4015 per procedure. Our institutional costs and length of stay, when benchmarked against comparable centers, remained in the lowest quartile nationally using University Health System Consortium costs for DRG 238. Stent graft price did not correlate with total EVAR market share. EVAR is currently associated with significant negative operating margins among Medicare beneficiaries. Currently, device costs account for over 50% of EVAR-associated technical costs and did not impact EVAR market share, reflecting an unawareness of cost differential among surgeons. These data indicate that EVAR must undergo dramatic care delivery redesign for this practice to remain sustainable. Copyright © 2014 Society for Vascular

  1. The role of inelastic deformations in the mechanical response of endovascular shape memory alloy devices.

    Science.gov (United States)

    Petrini, Lorenza; Bertini, Alessandro; Berti, Francesca; Pennati, Giancarlo; Migliavacca, Francesco

    2017-05-01

    Nickel-titanium alloys are commonly adopted for producing cardiovascular minimally invasive devices such as self-expandable stents, aortic valves and stent-grafts. These devices are subjected to cyclic loads (due to blood pulsatility, leg or heart movements), that can induce fatigue fracture, and may also be subjected to very large deformations (due to crimping procedure, a tortuous physiological path or overloads), that can induce material yield. Recently, the authors developed a new constitutive model that considers inelastic strains due to not-completed reverse phase transformation (not all the stress-induced martensite turns back to austenite) or/and plasticity and their accumulation during cyclic loads. In this article, the model is implemented in the finite element code ABAQUS/Standard and it is used to investigate the effects of inelastic strain accumulation on endovascular nickel-titanium devices. In particular, the behavior of a transcatheter aortic valve is studied considering the following steps: (1) crimping, (2) expansion in a tube resembling a durability test chamber and (3) cyclic loads due to pressure variation applied on the inner surface of the tube. The analyses are performed twice, activating and not activating that part of the new model which describes the development of irreversible strain. From the results, it is interesting to note that plasticity has a very significant effect on the local material response, inducing stress modification from compression to tension. However, permanent deformations are concentrated in few zones of the stent frame and their presence does not affect the global behavior of the device that maintains its capability of recovering the original shape. In conclusion, this work suggests that at least for cardiovascular devices where the crimping is high (local strain may reach values of 8%-9%), taking into account inelastic effects due to plasticity and not-completed reverse phase transformation can be important, and

  2. Endovascular Treatment Strategies in Aortoiliac Occlusion

    International Nuclear Information System (INIS)

    Ozkan, Ugur; Oguzkurt, Levent; Tercan, Fahri; Gumus, Burcak

    2009-01-01

    The aim of this study was to report our experience in endovascular treatment of total aortoiliac occlusion. Five patients who underwent endovascular recanalization procedures including manual aspiration thrombectomy, balloon angioplasty, and stent placement for total aortoiliac occlusion in a 4-year period were reviewed retrospectively. The mean age of patients was 51 years (range, 43 to 58 years). All patients had abdominal aorta and bilateral common iliac artery occlusion with or without external iliac artery occlusion. All patients either had a contraindication to surgery or refused it. Initial technical success was obtained in four of five (80%) patients. Endovascular techniques were successful in four patients who had good distal runoff and short-segment aortoiliac occlusion, but failed in a patient who had the worst distal runoff and long-segment aortoiliac occlusion. We observed two major complications, one of which was bilateral rupture of the common iliac arteries treated with covered stent placement. Another patient had extension of intra-aortic thrombus into the iliac stent after primary stenting. This was successfully treated with manual aspiration thrombectomy. Aortic and iliac stents remained patent during the follow-up period (median, 18 months; range, 3 to 26 months) in four patients. Primary patency rates at 6, 12, and 24 months were all 80%. In conclusion, endovascular treatment can be an alternative for aortoiliac occlusion in selected patients. Short- to midterm follow-up so far is satisfactory. Removal of intra-aortic thrombus with manual aspiration thrombectomy before balloon angioplasty and/or stenting is possible and a good alternative to thrombolysis.

  3. Endovascular treatment of head and neck arteriovenous malformations

    Energy Technology Data Exchange (ETDEWEB)

    Dmytriw, A.A. [University Health Network, Joint Department of Medical Imaging, Toronto, Ontario (Canada); Ter Brugge, K.G.; Krings, T.; Agid, R. [Toronto Western Hospital, Division of Neuroradiology, Department of Medical Imaging, Toronto, Ontario (Canada)

    2014-03-15

    Head and neck arteriovenous malformations (H and N AVM) are associated with considerable clinical and psychosocial burden and present a significant treatment challenge. We evaluated the presentation, response to treatment, and outcome of patients with H and N AVMs treated by endovascular means at our institution. Patients with H and N AVMs treated by endovascular means from 1984 to 2012 were evaluated retrospectively. These included AVMs involving the scalp, orbit, maxillofacial, and upper neck localizations. Patient's clinical files, radiological images, catheter angiograms, and surgical reports were reviewed. Eighty-nine patients with H and N AVMs (46 females, 43 males; 48 small, 41 large) received endovascular therapy. The goals of treatment were curative (n = 30), palliative (n = 34), or presurgical (n = 25). The total number of endovascular treatment sessions was 244 (average of 1.5 per patient). The goal of treatment was met in 92.1 % of cases. Eventual cure was achieved in 42 patients accounting for 58.4 % (52/89) of all patients who underwent treatment for any goal. Twenty-eight of these patients were cured by embolization alone (28/89, 31.4 %) of which 18 were single-hole AVFs. Twenty-four were cured by planned surgical excision after presurgical embolization (24/89, 27 %). Seven patients (7/89, 7.2 %) suffered transient and two (2/89, 2.2 %) permanent endovascular treatment complications. Endovascular treatment is effective for H and N AVMs and relatively safe. It is particularly effective for symptom palliation and presurgical aid. Embolization is curative mostly in small lesions and single-hole fistulas. In patients with large non-curable H and N AVMs, endovascular therapy is often the only palliative option. (orig.)

  4. Headache and endovascular procedures.

    Science.gov (United States)

    de Biase, Stefano; Longoni, Marco; Gigli, Gian Luigi; Agostoni, Elio

    2017-05-01

    The International Classification of Headache Disorders (ICHD-3 beta) includes headache attributed to intracranial endovascular procedures (EVPs). The aim of this review is to describe the clinical and pathophysiological aspects of headache related to vascular lesions and EVPs. Current studies regarding this issue are contradictory, although generally favouring headache improvement after EVPs. Further large studies are needed to adequately assess the effect of EVPs on headache.

  5. Total Endovascular Aortic Repair in a Patient with Marfan Syndrome.

    Science.gov (United States)

    Amako, Mau; Spear, Rafaëlle; Clough, Rachel E; Hertault, Adrien; Azzaoui, Richard; Martin-Gonzalez, Teresa; Sobocinski, Jonathan; Haulon, Stéphan

    2017-02-01

    The aim of this study is to describe a total endovascular aortic repair with branched and fenestrated endografts in a young patient with Marfan syndrome and a chronic aortic dissection. Open surgery is the gold standard to treat aortic dissections in patients with aortic disease and Marfan syndrome. In 2000, a 38-year-old man with Marfan syndrome underwent open ascending aorta repair for an acute type A aortic dissection. One year later, a redo sternotomy was performed for aortic valve replacement. In 2013, the patient presented with endocarditis and pulmonary infection, which necessitated tracheostomy and temporary dialysis. In 2014, the first stage of the endovascular repair was performed using an inner branched endograft to exclude a 77-mm distal arch and descending thoracic aortic aneurysm. In 2015, a 63-mm thoracoabdominal aortic aneurysm was excluded by implantation of a 4-fenestrated endograft. Follow-up after both endovascular repairs was uneventful. Total aortic endovascular repair was successfully performed to treat a patient with arch and thoraco-abdominal aortic aneurysm associated with chronic aortic dissection and Marfan syndrome. The postoperative images confirmed patency of the endograft and its branches, and complete exclusion of the aortic false lumen. Endovascular repair is a treatment option in patients with connective tissue disease who are not candidates for open surgery. Long-term follow-up is required to confirm these favorable early outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Comparison between endovascular repair and open surgery for isolated iliac artery aneurysms.

    Science.gov (United States)

    Igari, Kimihiro; Kudo, Toshifumi; Toyofuku, Takahito; Jibiki, Masatoshi; Inoue, Yoshinori

    2015-03-01

    This study was performed to compare endovascular repair with conventional open repair of isolated iliac artery aneurysms (IAAs). We retrospectively reviewed the charts of all patients who underwent repair of isolated IAAs between January 2008 and June 2012. Patients with infected, mycotic and ruptured iliac aneurysms and those with concurrent infrarenal abdominal aortic aneurysms greater than 30 mm in diameter were excluded from this analysis. A total of 32 patients were treated with isolated IAAs. There were 20 open and 12 endovascular repairs. A comparison of the length of the operation (238 ± 84 min in the open group vs 176 ± 72 min in the endovascular group, P = 0.03) and intraoperative blood loss (1,735 ± 1,177 ml in the open group vs 503 ± 711 ml in the endovascular group, P = 0.01), revealed significant differences in favor of the endovascular procedure. Postoperative complications were less common in the endovascular group, although the difference did not reach statistical significance. The management of isolated IAAs with both endovascular and open repair can be accomplished with very low morbidity rates. Therefore, endovascular repair can be considered an alternative treatment for isolated IAAs.

  7. Salvage of bilateral renal artery occlusion after endovascular aneurysm repair with open splenorenal bypass

    Directory of Open Access Journals (Sweden)

    Samuel Jessula, MDCM

    2017-09-01

    Full Text Available We report renal salvage maneuvers after accidental bilateral renal artery coverage during endovascular aneurysm repair of an infrarenal abdominal aortic aneurysm. A 79-year-old man with an infrarenal abdominal aortic aneurysm was treated with endovascular aneurysm repair. Completion angiography demonstrated coverage of the renal arteries. Several revascularization techniques were attempted, including endograft repositioning and endovascular stenting through the femoral and brachial approach. The patient eventually underwent open splenorenal bypass with a Y Gore-Tex graft (W. L. Gore & Associates, Flagstaff, Ariz. After 3 months, computed tomography showed no evidence of endoleak and patent renal arteries. Renal function was well maintained, and the patient did not require dialysis.

  8. Fístula aortoesofágica após correção endovascular da dissecção de aorta torácica tipo B de Stanford Aortic-esophageal fistula after endovascular repair of Stanford type B thoracic aortic dissection

    Directory of Open Access Journals (Sweden)

    Cláudia Gurgel Marques

    2010-01-01

    Full Text Available A correção endovascular da dissecção de aorta tipo B tem se mostrado como uma nova alternativa para reduzir o trauma cirúrgico. No entanto, as complicações de médio e longo prazo, tais como a fístula aortoesofágica, são ainda pouco conhecidas e pouco relatadas. O objetivo deste trabalho é descrever três casos de fístula aortoesofágica após o tratamento endovascular de 23 casos de dissecção de aorta descendente conduzidos pela equipe de Cirurgia Vascular da Santa Casa de São Paulo em um estudo retrospectivo. Esses pacientes apresentavam características em comum, como dissecção crônica, pós-operatório imediato sem intercorrências, necessidade de reintervenções, oclusão de troncos arteriais como a artéria subclávia, mesentérica, tronco celíaco, e, ainda, uma rápida evolução para o óbito após os primeiros sinais de fístula. Portanto, embora raramente descrita na literatura, a ocorrência de fístula aortoesofágica é uma complicação de causa até o momento indefinida do tratamento endovascular da dissecção de aorta descendente que merece atenção, dada sua recorrência e evolução fatal.Endoluminal stent-graft for type B aortic dissection is a new alternative to reduce surgical trauma. However, medium- and long-term complications are still little known and poorly reported, such as the aortic-esophageal fistula. The objective of this study is to describe three cases of aortic-esophageal fistula after the endovascular treatment of 23 cases of descending aortic dissection conducted by the vascular surgery team of Santa Casa de São Paulo in a retrospective study. These patients presented some common characteristics: chronic dissection, successful early outcome, need of reinterventions, occlusion of arterial trunks such as subclavian artery, mesenteric artery, celiac trunk, and finally, a fast fatal course after the first fistula-related symptoms. Therefore, despite rarely described in the literature, aortic

  9. Endovascular treatment of aortic arch aneurysms Tratamento endovascular dos aneurismas de arco aórtico

    Directory of Open Access Journals (Sweden)

    Roberto Chiesa

    2008-06-01

    Full Text Available BACKGROUND: Endovascular approach to the aortic arch is an appealing solution for selected patients. OBJECTIVE: To compare the technical and clinical success recorded in the different anatomical settings of endografting for aortic arch disease. METHODS: Between June 1999 and October 2006, among 178 patients treated at our institution for thoracic aorta disease with a stent-graft, the aortic arch was involved in 64 cases. According to the classification proposed by Ishimaru, aortic zone 0 was involved in 14 cases, zone 1 in 12 cases and zone 2 in 38 cases. A hybrid surgical procedure of supra-aortic debranching and revascularization was performed in 37 cases. RESULTS: Zone 0. Proximal neck length: 44±6 mm. Initial clinical success was 78.6%: two deaths (stroke, one type Ia endoleak. At a mean follow-up of 16.4±11 months the midterm clinical success was 85.7%. Zone 1. Proximal neck length: 28±5 mm. Initial clinical success was 66.7%: 0 deaths, four type Ia endoleaks. At a mean follow-up of 16.9±17.2 months the midterm clinical success was 75.0%. Zone 2. Proximal neck length: 30±5 mm. Initial clinical success was 84.2%: two deaths (one cardiac arrest, one multiorgan embolization, three type Ia endoleaks, one case of open conversion. Two cases of delayed transitory paraparesis/paraplegia were observed. At a mean follow-up of 28.0±17.2 months the midterm clinical success was 89.5%. CONCLUSIONS: This study and a literature review demonstrated that hybrid procedure for aortic arch pathology is feasible in selected patients at high risk for conventional surgery. Our experience is still limited by the relatively small sample size. We propose to reserve zone 1 for patients unfit for sternotomy or in cases with aortic neck length > 30 mm following left common carotid artery debranching. We recommend to perform complete aortic rerouting of the aortic arch in cases with lesser comorbidities and shorter aortic neck.CONTEXTO: O tratamento endovascular

  10. Increasing use of endovascular therapy in acute arterial injuries: analysis of the National Trauma Data Bank.

    Science.gov (United States)

    Reuben, Brian C; Whitten, Matthew G; Sarfati, Mark; Kraiss, Larry W

    2007-12-01

    The application of endovascular technology for the emergency treatment of traumatic vascular injuries is a new frontier. This study examines recent nationwide use of endovascular therapy in acute arterial traumatic injuries. This retrospective study used the National Trauma Data Bank (NTDB). Cases with a diagnosis of arterial vascular injury were identified according to the International Classification of Diseases, Ninth Revision, Clinical Modification, and procedure codes for endovascular therapy were selected. A descriptive analysis and multiple regressions were performed to identify variables predictive of outcomes. From 1994 to 2003, 12,732 arterial injuries were identified. Between 1997 (when the first endovascular repair was recorded in the NTDB) and 2003, 7286 open arterial repairs and 281 endovascular repairs were recorded for an overall utilization rate for endovascular procedures of 3.7%. The yearly number of endovascular procedures registered in the NTDB increased 27-fold, from four in 1997 to 107 in 2003. Use of stents substantially increased from 12 in 2000 to 30 in 2003; endograft use increased from one in 2000 to 37 in 2003. Nearly equal numbers of blunt (n = 134) and penetrating (n = 111) injuries were treated. The injury severity score (median, interquartile range [IRQ]) was significantly lower in patients who underwent an endovascular procedure at 13 (IRQ, 9 to 26) for trauma vs patients requiring an open procedure at 20 (IRQ, 10 to 34; P undergoing endovascular repair (8.7 +/- 7.2 vs 13.0 +/- 16.1, P undergoing endovascular procedures (odds ratio, 0.18; P = .029) including those with an arterial injury of the torso or head and neck (odds ratio, 0.51, P = .007). Total length of hospital stay also tended to be lower for patients undergoing endovascular procedures by 18% (P = .064). The use of endovascular therapy in the setting of acute trauma is increasing in a dramatic fashion and is being used to treat a wide variety of vessels injured by blunt

  11. The repair of a type Ia endoleak following thoracic endovascular aortic repair using a stented elephant trunk procedure.

    Science.gov (United States)

    Qi, Rui-Dong; Zhu, Jun-Ming; Liu, Yong-Min; Chen, Lei; Li, Cheng-Nan; Xing, Xiao-Yan; Sun, Li-Zhong

    2018-04-01

    Type Ia endoleaks are not uncommon complications that occur after thoracic endovascular aortic repair (TEVAR). Because aortic arch vessels prevent extension of the landing zone, it is very difficult to manipulate a type Ia endoleak using an extension cuff or stent-graft, especially when the aortic arch is involved. Here, we retrospectively review our experience of surgical treatment of type Ia endoleak after TEVAR using a stented elephant trunk procedure. From July 2010 to August 2016, we treated 17 patients diagnosed with a type Ia endoleak following TEVAR using stented elephant trunk procedure. The mean age of our patients was 52 ± 8 years. The mean interval between TEVAR and the open surgical repair was 38 ± 43 months. All cases of type Ia endoleak (100%) were repaired successfully. There were no in-hospital deaths. One case required reintubation and continuous renal replacement therapy due to renal failure; this patient recovered smoothly before discharge. One other patient suffered a stroke and renal failure and did not fully recover following discharge, or follow-up. During follow-up, there were 3 deaths. Acceptable results were obtained using a stented elephant trunk procedure in patients with a type Ia endoleak after TEVAR. This technique allowed us to repair the proximal aortic arch lesions, surgically correct the type Ia endoleak, and promote false lumen thrombosis in the distal aorta. Implantation of a stented elephant trunk, with or without a concomitant aortic arch procedure, is an alternative approach for this type of lesion. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  12. Durability of endovascular infrarenal aneurysm repair: when does late failure occur and why?

    Science.gov (United States)

    Chuter, Timothy A M

    2009-06-01

    The first commercially available stent grafts were unable to withstand the hemodynamic forces of the vascular environment. The past 15 years have seen a gradual improvement in long-term stent graft performance as designs evolved through the elimination of features associated with late failure and the replication of features associated with durable success. Clinical experience provides the following principles on which to base device design and implantation techniques. Few patients have an adequate length of non-dilated aorta distal to the aneurysm to allow implantation of an aorto-aortic stent graft; bifurcated stent grafts are usually required for AAA repair. Friction, column strength and tissue ingrowth do not prevent migration of the stent graft from its attachment within the neck into the aneurysm; some form of active fixation is required, usually in the form of barbs. Any movement between the apex of a stent and the overlying graft material will erode the fabric; stents and grafts need to move as a single unit. Nitinol is versatile, but fragile; Nitinol components must be polished to eliminate all surface irregularities and they cannot be subjected to compression loading, or excessive pulsatile movement. The neck of an aneurysm is unstable; it will dilate unless protected by a securely fixed, non-compliant stent graft. The aneurysm does not heal; freedom from risk of rupture depends on durable depressurization of the sac. The sole objective of image-based follow-up is the early detection, and catheter-based correction, of device failure. Once any given design has been in use long enough to identify its failure modes, the frequency of follow-up studies can be adjusted accordingly. However, it takes a long time to identify all the potential forms of late failure, and pre-clinical testing remains an imprecise science. New, or recently modified, devices cannot necessarily be assumed to be as durable as their predecessors.

  13. ENDOVASCULAR HEMOSTASIS IN UTERINE BLEEDING IN PATIENTS WITH UTERINE LEIOMYOMA

    Directory of Open Access Journals (Sweden)

    M. M. Damirov

    2017-01-01

    Full Text Available We report results of treatment for 72 patients with uterine leiomyoma (LM of various sizes and location, who had arrived with excessive uterine bleeding. All patients underwent urgent or urgently-delayed endovascular hemostasis by performing uterine arteries embolization (UAE. We analyzed clinical features of the disease after UAE in various sizes of tumors and studied immediate and long-term results of UAE in patients with LM.

  14. Endovascular and surgical treatment of spinal dural arteriovenous fistulas

    International Nuclear Information System (INIS)

    Andres, Robert H.; University of Berne; Stanford University Medical Center, Department of Neurosurgery, Stanford, CA; University of Berne; Barth, Alain; Medical University of Graz, Department of Neurosurgery, Graz; University of Berne; Guzman, Raphael; Stanford University Medical Center, Department of Neurosurgery, Stanford, CA; University of Berne; Remonda, Luca; El-Koussy, Marwan; Schroth, Gerhard; University of Berne; Seiler, Rolf W.; Widmer, Hans R.; University of Berne

    2008-01-01

    The aim of this retrospective study was to evaluate the clinical outcome of patients with spinal dural arteriovenous fistulas (SDAVFs) that were treated with surgery, catheter embolization, or surgery after incomplete embolization. The study included 21 consecutive patients with SDAVFs of the thoracic, lumbar, or sacral spine who were treated in our institution from 1994 to 2007. Thirteen patients were treated with catheter embolization alone. Four patients underwent hemilaminectomy and intradural interruption of the fistula. Four patients were treated by endovascular techniques followed by surgery. The clinical outcome was assessed using the modified Aminoff-Logue scale (ALS) for myelopathy and the modified Rankin scale (MRS) for general quality of life. Patient age ranged from 44 to 77 years (mean 64.7 years). Surgical as well as endovascular treatment resulted in a significant improvement in ALS (-62.5% and -31.4%, respectively, p<0.05) and a tendency toward improved MRS (-50% and -32%, respectively) scores. Patients that underwent surgery after endovascular treatment due to incomplete occlusion of the fistula showed only a tendency for improvement in the ALS score (-16.7%), whereas the MRS score was not affected. We conclude that both endovascular and surgical treatment of SDAVFs resulted in a good and lasting clinical outcome in the majority of cases. In specific situations, when a secondary neurosurgical approach was required after endovascular treatment to achieve complete occlusion of the SDAVF, the clinical outcome was rather poor. The best first line treatment modality for each individual patient should be determined by an interdisciplinary team. (orig.)

  15. Hygroma following endovascular femoral aneurysm exclusion

    DEFF Research Database (Denmark)

    Wad, Morten; Pedersen, Brian Lindegaard; Lönn, Lars

    2013-01-01

    Endovascular treatment of aneurysms in the superficial femoral artery (SFA) and popliteal segments is a suggested alternative to open surgical repair. Careful selection of patients for endovascular treatment of SFA aneurysms is mandatory.......Endovascular treatment of aneurysms in the superficial femoral artery (SFA) and popliteal segments is a suggested alternative to open surgical repair. Careful selection of patients for endovascular treatment of SFA aneurysms is mandatory....

  16. Endovascular treatment of thoracic aortic pathology: Feasibility and mid-term results

    NARCIS (Netherlands)

    Lamme, B.; de Jonge, I. C. D. Y. M.; Reekers, J. A.; de Mol, B. A. J. M.; Balm, R.

    2003-01-01

    Objective: to report our experience with 21 consecutive patients treated with a thoracic stent-graft. Design: retrospective analysis. Materials and Methods: Between October 1998 and February 2002, 21 patients (12 male), mean age 55.6 years (range 19-86 years), were treated for aorticortic pathology

  17. From puncture to closure of the common femoral artery in endovascular aortic repair

    DEFF Research Database (Denmark)

    Lönn, Lars; Larzon, Thomas; Van Den Berg, Jos C

    2010-01-01

    of today. The traditional approach in EVAR involves surgical exposure of the femoral arteries with bilateral groin incisions. Through the groin access, and under fluoroscopy, a special insertion sheath introducer is used to position a stent graft in the desired location with the patient in general...

  18. Endovascular Treatment of a Vertebral Artery Pseudoaneurysm in a Drug User

    International Nuclear Information System (INIS)

    Mourikis, Dimitrios; Chatziioannou, Achilleas; Doriforou, Ortansia; Skiadas, Vasilios; Koutoulidis, Vasilios; Katsenis, Konstantinos; Vlahos, Lampros

    2006-01-01

    A 26-year-old drug abuser who presented with sepsis was found to have a pseudoaneurysm in the left vertebral artery. This aneurysm was presumed to be post-traumatic, since the patient reported multiple attempts to inject drugs in the left jugular vein 15 days prior to admission. The pseudoaneurysm was treated effectively with stent-graft placement

  19. Endovascular treatment of PICA aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Mukonoweshuro, W.; Laitt, R.D.; Hughes, D.G. [Radiology Dept., Greater Manchester Neurosciences Unit, Hope Hospital, Salford, Manchester (United Kingdom)

    2003-03-01

    Endovascular treatment of aneurysms of the posterior inferior cerebellar artery (PICA) avoids manipulation of the brainstem or lower cranial nerves and should therefore carry a lower risk of neurological morbidity than surgical clipping. We reviewed our experience of 23 patients with PICA aneurysms treated by endovascular occlusion with Guglielmi detachable coils and documented their long-term outcome on follow-up. We observed a 28 day procedure-related neurological morbidity of 13% (3/23 patients). One patient suffered permanent neurological complications. There were no procedure-related deaths. None of our patients suffered a re-bleed from their treated aneurysms. Our series shows endovascular treatment of ruptured PICA aneurysms to be safe and effective. (orig.)

  20. Carotid artery sacrifice for unclippable and uncoilable aneurysms: endovascular occlusion vs common carotid artery ligation.

    Science.gov (United States)

    Elhammady, Mohamed Samy; Wolfe, Stacey Quintero; Farhat, Hamad; Ali Aziz-Sultan, Mohammad; Heros, Roberto C

    2010-11-01

    Optimal treatment of intracranial aneurysms involves complete occlusion of the aneurysm with preservation of the parent artery and all of its branches. Attempts to occlude the aneurysm and preserve the parent artery may be associated with a higher level of risk than parent vessel occlusion or trapping. To evaluate our series of patients with large and giant aneurysms who underwent treatment via endovascular coiling with parent artery sacrifice or surgical ligation of the common carotid artery (CCA) and gain insight into the advantages and risks of each of these alternatives. We retrospectively reviewed all patients with aneurysms who underwent carotid sacrifice via endovascular occlusion or surgical CCA ligation during an 8-year period at our institution. Twenty-seven patients with large and giant aneurysms of the internal carotid artery underwent carotid artery sacrifice via endovascular occlusion (n = 15) or CCA ligation (n = 12). Of the patients who underwent endovascular occlusion, 3 developed groin complications, 1 developed a new sixth nerve palsy, 1 died from vasospasm related to subarachnoid hemorrhage, and 1 died secondary to rupture of an associated 3-mm anterior communicating artery aneurysm 5 days postoperatively. Of the patients undergoing CCA ligation, 1 patient developed a partial hypoglossal palsy. Clinical improvement of presenting symptoms was observed in all surviving patients regardless of the method of treatment. Complete aneurysm obliteration was documented in all patients during the initial hospital stay. The mean radiographic long-term follow-up was 14.2 months, which was available in 20 of the 25 surviving patients (80%). Complete obliteration was confirmed at follow-up in all but 2 patients with large cavernous aneurysms; 1 was initially treated with endovascular occlusion and the other with carotid ligation. Parent artery sacrifice is still a viable treatment for some complex aneurysms of the internal carotid artery. CCA ligation is a

  1. Comparative Cost Analysis for Surgical and Endovascular Treatment of Unruptured Intracranial Aneurysms in South Korea.

    Science.gov (United States)

    Kim, Myungsoo; Park, Jaechan; Lee, Joomi

    2015-06-01

    A cost comparison of the surgical clipping and endovascular coiling of unruptured intracranial aneurysms (UIAs), and the identification of the principal cost determinants of these treatments. This study conducted a retrospective review of data from a series of patients who underwent surgical clipping or endovascular coiling of UIAs between January 2011 and May 2014. The medical records, radiological data, and hospital cost data were all examined. When comparing the total hospital costs for surgical clipping of a single UIA (n=188) and endovascular coiling of a single UIA (n=188), surgical treatment [mean±standard deviation (SD) : ₩8,280,000±1,490,000] resulted in significantly lower total hospital costs than endovascular treatment (mean±SD : ₩11,700,000±3,050,000, p<0.001). In a multi regression analysis, the factors significantly associated with the total hospital costs for endovascular treatment were the aneurysm diameter (p<0.001) and patient age (p=0.014). For the endovascular group, a Pearson correlation analysis revealed a strong positive correlation (r=0.77) between the aneurysm diameter and the total hospital costs, while a simple linear regression provided the equation, y (₩)=6,658,630+855,250x (mm), where y represents the total hospital costs and x is the aneurysm diameter. In South Korea, the total hospital costs for the surgical clipping of UIAs were found to be lower than those for endovascular coiling when the surgical results were favorable without significant complications. Plus, a strong positive correlation was noted between an increase in the aneurysm diameter and a dramatic increase in the costs of endovascular coiling.

  2. Endovascular abdominal aortic aneurysm repair complicated by spondylodiscitis and iliaco-enteral fistula.

    NARCIS (Netherlands)

    Koning, H.D. de; Sterkenburg, S.M. van; Pierie, M.; Reijnen, M.M.P.J.

    2008-01-01

    Infections of abdominal aortic endografts are rare. There are no reports on the association with spondylodiscitis. We report a case of a 74-year-old man who underwent endovascular aneurysm repair (EVAR) and subsequently femorofemoral bypass placement due to occlusion of the right limb of the

  3. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    Energy Technology Data Exchange (ETDEWEB)

    Muehlenbruch, Georg, E-mail: gmuehlenbruch@ukaachen.de; Nikoubashman, Omid; Steffen, Bjoern; Dadak, Mete [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany); Palmowski, Moritz [RWTH Aachen University, Department of Nuclear Medicine, University Hospital (Germany); Wiesmann, Martin [RWTH Aachen University, Department of Diagnostic and Interventional Neuroradiology, University Hospital (Germany)

    2013-02-15

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  4. Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

    International Nuclear Information System (INIS)

    Mühlenbruch, Georg; Nikoubashman, Omid; Steffen, Björn; Dadak, Mete; Palmowski, Moritz; Wiesmann, Martin

    2013-01-01

    Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

  5. Parallel-Stenting Technique in a Sandwich Configuration for Hypogastric Artery Preservation during Endovascular Aneurysm Repair: An In Vitro Study.

    Science.gov (United States)

    Yugueros, Xavier; Mestres, Gaspar; Pasquadibisceglie, Savino; Alomar, Xavier; Apodaka, Ana; Riambau, Vincent

    2017-10-01

    The aim of the study was to identify the best conditions in iliac sandwich procedure for hypogastric artery preservation during endovascular aneurysm repair, testing different devices, different oversizing (OS) degrees as well as different methods to measure it. Four external iliac devices (16-mm Endurant and 12-mm Aorfix limb extensions; 11- and 13-mm Viabahn endografts) were tested with 2 distinct internal iliac stent grafts (8-mm Advanta V12 and 8-mm Viabahn) inside different proximal silicon iliac limb models (10, 12, 14, 16, and 18 mm), simulating an iliac sandwich procedure for hypogastric preservation. After remodeling all devices in a saline bath at 37°C, the combinations were computed tomography scanned. Gutter size, parallel-stent compression, and inadequate parallel-stent deployment or infolding were recorded. Oversizing between both parallel stents and the iliac limb models were examined in terms of added diameter, perimeter, and area being additionally compared. All three sizing methods (diameter, perimeter, and area) were highly correlated (diameter OS to perimeter and area OS correlation coefficient 0.998 and 0.997, respectively, P  75%) showed a significant tendency toward smaller gutters (38.9, 12.2, 5.4, and 2.6 mm 2 , respectively, P parallel-stent compression (13.5%, 28.9%, 43.9%, and 55.1%, P parallel-stent compression. No clear recommendations in material selection can be performed. All sizing methods are highly correlated and predictable. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Endovascular Treatment of Totally Occluded Superior Mesenteric Artery by Retrograde Crossing via the Villemin Arcade

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Carlo; Rossi, Umberto G., E-mail: urossi76@hotmail.com; Seitun, Sara; Bovio, Giulio [IRCCS San Martino University Hospital-IST-National Institute for Cancer Research, Department of Radiology and Interventional Radiology (Italy); Fornaro, Rosario [IRCCS San Martino University Hospital-IST-National Institute for Cancer Research, Department of Surgery (Italy)

    2013-06-15

    Chronic mesenteric ischemia (CMI) is a rare disorder that is commonly caused by progressive atherosclerotic stenosis or occlusion of one or more mesenteric arteries. Endovascular treatment for symptomatic CMI represents a viable option, especially in high-operative risk patients. We report a case of acute symptomatic CMI with chronic totally occlusion of the superior mesenteric artery (SMA) associated with significant stenosis of celiac trunk (CT) and inferior mesenteric artery (IMA) that underwent endovascular treatment of all the three mesenteric arteries: stenting of CT and IMA stenosis, and recanalization of the SMA occlusion by retrograde crossing via the Villemin arcade.

  7. Endovascular Treatment of Totally Occluded Superior Mesenteric Artery by Retrograde Crossing via the Villemin Arcade

    International Nuclear Information System (INIS)

    Ferro, Carlo; Rossi, Umberto G.; Seitun, Sara; Bovio, Giulio; Fornaro, Rosario

    2013-01-01

    Chronic mesenteric ischemia (CMI) is a rare disorder that is commonly caused by progressive atherosclerotic stenosis or occlusion of one or more mesenteric arteries. Endovascular treatment for symptomatic CMI represents a viable option, especially in high-operative risk patients. We report a case of acute symptomatic CMI with chronic totally occlusion of the superior mesenteric artery (SMA) associated with significant stenosis of celiac trunk (CT) and inferior mesenteric artery (IMA) that underwent endovascular treatment of all the three mesenteric arteries: stenting of CT and IMA stenosis, and recanalization of the SMA occlusion by retrograde crossing via the Villemin arcade.

  8. Systemic hypersensitivity reaction to endovascular stainless steel stent.

    Science.gov (United States)

    Univers, Junior; Long, Chandler; Tonks, Stephen A; Freeman, Michael B

    2018-02-01

    Endovascular intervention has become the mainstay for treatment of most patients suffering from peripheral vascular disease. We describe a patient with a known nickel allergy who underwent placement of a stainless steel stent for aortoiliac occlusive disease. Despite our attempt to avoid a nickel-containing stent, the patient developed a diffuse rash consistent with a nickel or metal allergy. A review of stainless steel metallurgy revealed that nickel, cobalt, and titanium are frequently used to provide anticorrosive properties to stainless steel. The clinical significance of the use of nickel-alloy stents in the setting of patients with a nickel allergy is discussed. Published by Elsevier Inc.

  9. Early experience of endovascular treatment of peripheral vascular disease

    International Nuclear Information System (INIS)

    Ashraf, T.; Yousuf, K.; Karim, M.T.

    2015-01-01

    Atherosclerotic peripheral arterial disease (PAD) is prevalent affecting up to 16% of the population aged 55 years or older. Endovascular intervention for the treatment of limb ischemia has become the first line therapy but in Pakistan it is in embryonic stage due to dearth of trained persons and dedicated centres. This study was conducted to evaluate procedural success and early outcome of endovascular treatment of peripheral vascular disease. Methods: A prospective single arm multicentre study was conducted at the National Institute of Cardiovascular Disease and National Medical Centre, Karachi, Pakistan from January 2013 to June 2014. A total of 25 patients were enrolled in the study that underwent endovascular treatment. Out of 25 patients 23 (92%) had critical limb ischemia (CLI) as per TASC II classification (A to D) and 2 (8%) had carotid lesion with history of TIA. Patients of acute limb ischemia and stroke were excluded. Ankle brachial index (ABI) was classified as normal (0.9-1.3), mild (0.7-0.9), moderate (0.4-0.69), severe (<0.4). Outcome was taken as immediate success and symptoms, amputation of limb among CLI patients and incidence of stroke in patients with carotid artery lesion at end of six months. Results: Among aortoiliac, femoropopliteal and tibioperoneal lesions, tibioperoneal lesions at six months were found to be more symptomatic 6 (86%) and amputation 4 (57%). Two carotid lesions at follow up were asymptomatic without stroke. Conclusion: Endovascular treatment of peripheral vascular lesions, i.e., aortoiliac, femoropopliteal tibioperoneal and carotid lesions were satisfactory in immediate outcome. Tibioperoneal lesions were more symptomatic and limb amputation at six months. (author)

  10. Outcomes of Infrainguinal Revascularizations with Endovascular First Strategy in Critical Limb Ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Jens, Sjoerd, E-mail: s.jens@amc.uva.nl [Academic Medical Center, Department of Radiology (Netherlands); Conijn, Anne P., E-mail: a.p.conijn@amc.uva.nl; Frans, Franceline A., E-mail: f.a.frans@amc.uva.nl [Academic Medical Center, Departments of Radiology and Surgery (Netherlands); Nieuwenhuis, Marieke B. B., E-mail: m.b.nieuwenhuis@amc.uva.nl; Met, Rosemarie, E-mail: rosemariemet@hotmail.com [Academic Medical Center, Department of Radiology (Netherlands); Koelemay, Mark J. W., E-mail: m.j.koelemaij@amc.uva.nl; Legemate, Dink A., E-mail: d.a.legemate@amc.uva.nl [Academic Medical Center, Department of Surgery (Netherlands); Bipat, Shandra, E-mail: s.bipat@amc.uva.nl; Reekers, Jim A., E-mail: j.a.reekers@amc.uva.nl [Academic Medical Center, Department of Radiology (Netherlands)

    2015-06-15

    PurposeThis study was designed to study the outcome of infrainguinal revascularization in patients with critical limb ischemia (CLI) in an institution with a preference towards endovascular intervention first in patients with poor condition, unfavourable anatomy for surgery, no venous material for bypass, and old age.MethodsA prospective, observational cohort study was conducted between May 2007 and May 2010 in patients presenting with CLI. At baseline, the optimal treatment was selected, i.e., endovascular or surgical treatment. In case of uncertainty about the preferred treatment, a multidisciplinary team (MDT) was consulted. Primary endpoints were quality of life and functional status 6 and 12 months after initial intervention, assessed by the VascuQol and AMC Linear Disability Score questionnaires, respectively.ResultsIn total, 113 patients were included; 86 had an endovascular intervention and 27 had surgery. During follow-up, 41 % underwent an additional ipsilateral revascularisation procedure. For the total population, and endovascular and surgery subgroups, the VascuQol sum scores improved after 6 and 12 months (p < 0.01 for all outcomes) compared with baseline. The functional status improved (p = 0.043) after 12 months compared with baseline for the total population. Functional status of the surgery subgroup improved significantly after 6 (p = 0.031) and 12 (p = 0.044) months, but not that of the endovascular subgroup.ConclusionsOverall, the strategy of performing endovascular treatment first in patients with poor condition, unfavourable anatomy for surgery, no venous material for bypass, and old age has comparable or even slightly better results compared with the BASIL trial and other cohort studies. All vascular groups should discuss whether their treatment strategy should be directed at treating CLI patients preferably endovascular first and consider implementing an MDT to optimize patient outcomes.

  11. Outcomes of Infrainguinal Revascularizations with Endovascular First Strategy in Critical Limb Ischemia

    International Nuclear Information System (INIS)

    Jens, Sjoerd; Conijn, Anne P.; Frans, Franceline A.; Nieuwenhuis, Marieke B. B.; Met, Rosemarie; Koelemay, Mark J. W.; Legemate, Dink A.; Bipat, Shandra; Reekers, Jim A.

    2015-01-01

    PurposeThis study was designed to study the outcome of infrainguinal revascularization in patients with critical limb ischemia (CLI) in an institution with a preference towards endovascular intervention first in patients with poor condition, unfavourable anatomy for surgery, no venous material for bypass, and old age.MethodsA prospective, observational cohort study was conducted between May 2007 and May 2010 in patients presenting with CLI. At baseline, the optimal treatment was selected, i.e., endovascular or surgical treatment. In case of uncertainty about the preferred treatment, a multidisciplinary team (MDT) was consulted. Primary endpoints were quality of life and functional status 6 and 12 months after initial intervention, assessed by the VascuQol and AMC Linear Disability Score questionnaires, respectively.ResultsIn total, 113 patients were included; 86 had an endovascular intervention and 27 had surgery. During follow-up, 41 % underwent an additional ipsilateral revascularisation procedure. For the total population, and endovascular and surgery subgroups, the VascuQol sum scores improved after 6 and 12 months (p < 0.01 for all outcomes) compared with baseline. The functional status improved (p = 0.043) after 12 months compared with baseline for the total population. Functional status of the surgery subgroup improved significantly after 6 (p = 0.031) and 12 (p = 0.044) months, but not that of the endovascular subgroup.ConclusionsOverall, the strategy of performing endovascular treatment first in patients with poor condition, unfavourable anatomy for surgery, no venous material for bypass, and old age has comparable or even slightly better results compared with the BASIL trial and other cohort studies. All vascular groups should discuss whether their treatment strategy should be directed at treating CLI patients preferably endovascular first and consider implementing an MDT to optimize patient outcomes

  12. Endovascular blood flow measurement system

    Science.gov (United States)

    Khe, A. K.; Cherevko, A. A.; Chupakhin, A. P.; Krivoshapkin, A. L.; Orlov, K. Yu

    2016-06-01

    In this paper an endovascular measurement system used for intraoperative cerebral blood flow monitoring is described. The system is based on a Volcano ComboMap Pressure and Flow System extended with analogue-to-digital converter and PC laptop. A series of measurements performed in patients with cerebrovascular pathologies allows us to introduce “velocity-pressure” and “flow rate-energy flow rate” diagrams as important characteristics of the blood flow. The measurement system presented here can be used as an additional instrument in neurosurgery for assessment and monitoring of the operation procedure. Clinical data obtained with the system are used for construction of mathematical models and patient-specific simulations. The monitoring of the blood flow parameters during endovascular interventions was approved by the Ethics Committee at the Meshalkin Novosibirsk Research Institute of Circulation Pathology and included in certain surgical protocols for pre-, intra- and postoperative examinations.

  13. Endovascular Treatment for Aneurysmal Subarachnoid Hemorrhage with Neurogenic Pulmonary Edema in the Acute Stage.

    Science.gov (United States)

    Meguro, Toshinari; Tanabe, Tomoyuki; Muraoka, Kenichiro; Terada, Kinya; Hirotsune, Nobuyuki; Nishino, Shigeki

    2016-01-01

    Severe neurogenic pulmonary edema (NPE) can occur in a variety of brain insults, including subarachnoid hemorrhage (SAH), and severe case of NPE can cause devastating consequences. But the literature on the treatment strategy about aneurysmal SAH with NPE is very scant. We present that SAH patients with severe NPE, who were treated first by embolization of aneurysm followed by insertion of lumbar spinal drainage, had comparatively good outcome. We present 12 consecutive cases of aneurysmal SAH with NPE in the acute stage, which were treated by endovascular treatment between April 2002 and December 2012. We classified the patients according to the Hunt and Hess grading system as follows: grade-3 (1 patient), grade-4 (4 patients), and grade-5 (7 patients). All patients needed respiratory management, with the assistance of a ventilator, and underwent endovascular treatment for the ruptured aneurysms within 72 hours from onset. For all the patients, immediately after the endovascular treatment, we performed lumbar spinal drainage. The pulmonary edema disappeared rapidly after respiratory management and endovascular treatment. The outcomes were as follows: good recovery (GR; 3 patients), moderate disability (MD; 4 patients), severe disability (SD; 3 patients), and death (D; 2 patients). Five patients (42%) developed pneumonia, and we postponed extubation until recovery from pneumonia. The cause for severe disability and death was symptomatic vasospasm and primary brain damage. No patients had rebleeding from ruptured aneurysms. Endovascular treatment for ruptured aneurysm and placement of lumbar spinal drainage is an excellent treatment option for severe SAH with NPE.

  14. ORIGINAL ARTICLES Endovascular treatment of cerebral ...

    African Journals Online (AJOL)

    ORIGINAL ARTICLES. Endovascular treatment of cerebral aneurysms - a cost analysis. David Le Feuvre, Allan Taylor. Objectives. To determine if endovascular treatment of cerebral aneurysms is cost effective when compared with conventional surgical treatment. Design. A retrospective study. Subjects. Seventeen patients ...

  15. A look into the endovascular crystal ball

    DEFF Research Database (Denmark)

    Schroeder, Torben Veith

    2009-01-01

    This paper summarizes the highlights of the 15th International Workshop of Endovascular Surgery, held in Ajaccio in June 2008. This is an annual event that attracts leading endovascular therapists from both sides of the Atlantic Ocean as well as a contingency from down-under. The layout of this m...

  16. Neonatal Intracranial Aneurysm Rupture Treated by Endovascular Management: A Case Report

    Directory of Open Access Journals (Sweden)

    Yi-Pei Tai

    2010-08-01

    Full Text Available Pediatric intracranial aneurysm rupture is rare, and is traditionally managed by surgical clipping. To the best of our knowledge, endovascular embolization of aneurysms in neonates has not previously been reported in Taiwan. We report a 9-day-old boy with intracranial aneurysms who underwent endovascular embolization, representing the youngest reported case in Taiwan. The 9-day-old boy presented with non-specific symptoms of irritable crying, seizure and respiratory distress. Computed tomography disclosed intraventricular hemorrhage, subarachnoid hemorrhage and focal intracranial hemorrhage around the right cerebellum. Subsequent computed tomographic angiography showed two sequential fusiform aneurysms, measuring 3 mm, located in the right side posterior inferior cerebellar artery (PICA. The patient underwent endovascular embolization because of the high risk of aneurysm re-rupture and the impossibility of surgical clipping due to the fusiform nature of the aneurysms. A postembolization angiogram revealed complete obliteration of the right distal PICA and proximal aneurysm. The distal PICA aneurysm was revascularized from the collateral circulation, but demonstrated a slow and delayed filling pattern. The patient's condition remained stable over the following week, and he was discharged without anticonvulsant therapy. No significant developmental delay was noted at follow-up at when he was 3 months old. This case emphasizes the need for clinical practitioners to consider a diagnosis of intracranial hemorrhage in neonates with seizure and increased intracranial pressure. Neonatal intracranial aneurysms can be treated safely by endovascular treatment.

  17. Percutaneous Endovascular Radiofrequency Ablation for Malignant Portal Obstruction: An Initial Clinical Experience

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tian-Tian, E-mail: matthewwu1979@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China); Li, Hu-Cheng, E-mail: hucheng-li-surgery@126.com [The 307th Hospital of PLA, General Surgery Department (China); Zheng, Fang, E-mail: fang-zheng-surgery@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China); Ao, Guo-Kun, E-mail: guokun-ao-radiology@126.com; Lin, Hu, E-mail: hu-lin-radiology@126.com [The 309th Hospital of PLA, Radiology Department (China); Li, Wei-Min, E-mail: weimin-li-surgery@126.com [The 309th Hospital of PLA, Hepatobiliary Surgery Department (China)

    2016-07-15

    PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portal stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.

  18. Are there fewer complications with third generation endografts in endovascular aneurysm repair?

    DEFF Research Database (Denmark)

    Jayia, P; Constantinou, J; Morgan-Rowe, L

    2013-01-01

    compared to open surgery in short and mid-term follow-up. The first pioneer devices had a high failure rate due to stent migration. This led to the creation of the first generation stent-grafts, which were associated with complications such as thrombosis of the limbs, graft migration and major endoleaks...... devices led to the development of the second generation stent-grafts. The improvements with regards to the delivery systems, enabled reposition of the top-stent following deployment in some devices. The number of devices commercially available increased with the second generation. The third generation...... branches and fenestrations in order to best accommodate the aortic anatomy of the patient. However, many issues remain with the development of this technology. There is a need for durable systems with less complicated deployment mechanics in order to be applied and more widespread. In conclusion, the third...

  19. Political issues in endovascular surgery.

    Science.gov (United States)

    Rutherford, R B

    1992-08-01

    "Political issues" may determine the relative progress if not the ultimate success and acceptance of endovascular surgery as much as its intrinsic merits. These issues include turf battles, commercialization of newly developing technologies, unethical advertising, and self-serving reporting practices in presenting clinical results. Acceptable indications, methods of evaluating results, standardized reporting practices, appropriate "gold standards" for comparison, and controlled trials (without premature release) are recommended, as well as an emphasis on the future need for proper training and credentialing and quality assurance programs.

  20. CONTEMPORARY ENDOVASCULAR TREATMENT OF INTRACRANIAL ANEURYSMS

    Directory of Open Access Journals (Sweden)

    Dragan Stojanov

    2015-06-01

    Full Text Available In the past twenty years we have witnessed a revolution in the treatment of intracranial aneurysms. Endovascular technique and materials have rapidly developed since the approval of Guglielmi detachable coils in 1995 which now allow successful treatment of most aneurysms. The development of intracranial stents and balloons for stent-assisted coiling and balloon-remodeling technique further expanded the spectrum of aneurysms treatable with endovascular technique. For these reasons, the aim of this review was to describe endovascular technique and materials which we use in our daily practice, to show benefits of endovascular treatment and to discus complications of endovascular treatment and surgical treatment of intracranial aneurysms. Endovascular treatment is more comfortable for the patient not only because it is minimally invasive but also because it does not require long hospitalization equal to that after surgical treatment. It is a fact that with further development of endovascular materials, this a procedure will have even a more significant place in the treatment of intracranial aneurysms.

  1. Endovascular treatment of intracranial aneurysm

    International Nuclear Information System (INIS)

    Wang Zhigang; Li Guoxin; Qu Yuanming; Tang Jun; Liu Zuoqin

    2001-01-01

    Objective: To setup an endovascular treatment of intracranial aneurysm with detachable balloon and micro-coil. Methods: Trans-femoral artery Seldinger's catheterization was used. Balloons and free MDS, GDC micro-coils were pushed into the aneurysm or carrying arteries. Results: No mortality occurred in authors' group. Internal carotid arteries (ICA) were occluded with detachable balloons in 5 aneurysms at sinus segment of ICA and 4 traumatic pseudo-aneurysms. No complications occurred. 9 aneurysms were completely occluded with micro-coils and 2 were partly (95%) occluded. 2 patients got mild paralysis due to vasospasm or mal detaching of MDS coils. Conclusions: Balloon occlusion of ICA for treatment of aneurysm at sinus segment is safe and effective in case of having abundant collateral circulation. Coil occlusion of intracranial aneurysm is a promising method of endovascular treatment. Compared with MDS, GDC coil is safer but expensive. Free coil is not very safe theoretically, but can be used with careful consideration as it is much cheaper

  2. Fenestrated endovascular aortic aneurysm repair using physician-modified endovascular grafts versus company-manufactured devices.

    Science.gov (United States)

    Dossabhoy, Shernaz S; Simons, Jessica P; Flahive, Julie M; Aiello, Francesco A; Sheth, Parth; Arous, Edward J; Messina, Louis M; Schanzer, Andres

    2017-12-07

    Fenestrated endografts are customized, patient-specific endovascular devices with potential to reduce morbidity and mortality of complex aortic aneurysm repair. With approval from the U.S. Food and Drug Administration, our center began performing fenestrated endovascular aneurysm repair through a physician-sponsored investigational device exemption (IDE #G130210), using both physician-modified endografts (PMEGs) and company-manufactured devices (CMDs). Because these techniques are associated with specific advantages and disadvantages, we sought to investigate differences in outcomes between PMEG and CMD cases. A single-institution retrospective review of all fenestrated endovascular aneurysm repairs was performed. The cohort was analyzed by device type (PMEG or CMD) after matching of cases on the basis of (1) number of target vessels intended for treatment, (2) extent of aneurysm, (3) aneurysm diameter, (4) device configuration, and (5) date of operation. Outcomes of ruptures, common iliac artery aneurysms, and aortic arch aneurysms were excluded. Demographics, operative details, perioperative complications, length of stay, and reinterventions were compared. For patients with >1 year of follow-up time, survival, type I or type III endoleak rate, target artery patency, and reintervention rate were estimated using the Kaplan-Meier method. Between November 30, 2010, and July 30, 2016, 82 patients were identified and matched. The cohort included 41 PMEG and 41 CMD patients who underwent repair of 38 juxtarenal (PMEG, 17; CMD, 21; P = .38), 14 pararenal (PMEG, 6; CMD, 8; P = .56), and 30 thoracoabdominal type I to type IV (PMEG, 18; CMD, 12; P = .17) aneurysms. There were significant differences in presentation requiring urgent aneurysm repair (PMEG, 9; CMD, 0; P = .002), total fluoroscopy time (PMEG, 76 minutes; CMD, 61 minutes; P = .02), volume of contrast material used (PMEG, 88 mL; CMD, 70 mL; P = .02), in-operating room to out-of-operating room time

  3. Endovascular Treatment of Deep Vein Thrombosis.

    Science.gov (United States)

    Javier, Julian J

    2014-10-01

    Venous thromboembolism (VTE) is associated with substantial morbidity and mortality. Conventional treatment with anticoagulation therapy may undertreat the condition. Patients with VTE are at risk for recurrence with increasing time passage. Endovascular approaches exist for treating VTE, including deep vein thrombosis, but it is unclear which patients are appropriate candidates for endovascular versus medical approaches. Many new endovascular technologies are in development, and new oral anticoagulants are also on the market. Clinicians must be mindful of these new products and use them appropriately to better manage VTE. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Endovascular neurosurgery in the United States: a survey of 59 vascular neurosurgeons with endovascular training.

    Science.gov (United States)

    Lanzino, Giuseppe; Rabinstein, Alejandro A

    2011-01-01

    We sought to assess general aspects of endovascular neurosurgery training, practice, and management for the treatment of intracranial aneurysms, arteriovenous malformations, acute ischemic stroke, and extracranial or intracranial occlusive disease within neurosurgery training and practice in the United States. A questionnaire was sent electronically to 80 U.S. neurosurgeons with endovascular training. Fifty-nine surveys (74%) were returned. Survey responses illustrated different practice patterns and varying management of cerebrovascular disorders by neurosurgeons with endovascular training. Our findings provide a snapshot of current neurosurgical endovascular practices in the United States. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. Classic and endovascular surgical management of isolated iliac artery aneurysms.

    Science.gov (United States)

    Gabrielli, R; Irace, L; Felli, M M G; Alunno, A; Rizzo, A R; Faccenna, F; Laurito, A; Gattuso, R; Venosi, S; Jabbour, J; Gossetti, B

    2007-04-01

    Isolated iliac artery aneurysm is a rare pathology that is often asymptomatic for long periods; this late diagnosis exposes patients to a high risk of death following aneurysm rupture. The aim of this study was to establish the most suitable diagnostic approach, the correct indications for treatment, and the most appropriate tactics and surgical technique. Twenty-eight patients were observed over 13 years. Aneurysmal involvement was unilateral in 22 cases and bilateral in the remaining 6 patients. Preoperative diagnostic tests included eco-colour Doppler (ECD) and angio-CT in all cases, with angio-MR and angiography as more selective procedures. Seventeen patients underwent conventional open surgery with prosthetic replacement of the aneurysmatic tract, 7 patients were treated using endovascular exclusion, and lastly 4 were monitored over time. There was no perioperative mortality for either treatment. During the postoperative period following conventional open surgery, complications included one case of severe respiratory failure, one microembolism of the lower limb, and 2 periprosthetic hematoma. During the follow-up, we observed one pseudo-aneurysm, 3 cases of retrograde ejaculation and one patient with erectile dysfunction after traditional surgery; there was one minor endoleak after endovascular exclusion. Our experience suggests that ECD is a useful method for arriving at an early diagnosis, while angio-CT imaging is essential for a correct preoperative study. Aneurysms with a diameter equal or greater than 3 cm or that present annual increases in excess of 5 mm represent a correct indication for treatment. Conventional open surgery is the treatment of choice for young patients in good general conditions. Endovascular exclusion is indicated when the patient's clinical conditions contraindicate open surgery and the morphology of the aneurysmal arterial district allows the endoprosthesis to be safely implanted.

  6. Management and outcome of cardiac and endovascular cystic echinococcosis.

    Directory of Open Access Journals (Sweden)

    Marta Díaz-Menéndez

    2012-01-01

    Full Text Available BACKGROUND: Cystic echinococcosis (CE can affect the heart and the vena cava but few cases are reported. METHODS: A retrospective case series of 11 patients with cardiac and/or endovascular CE, followed-up over a period of 15 years (1995-2009 is reported. RESULTS: Main clinical manifestations included thoracic pain or dyspnea, although 2 patients were asymptomatic. Cysts were located mostly in the right atrium and inferior vena cava. Nine patients were previously diagnosed with disseminated CE. Echocardiography was the diagnostic method of choice, although serology, electrocardiogram, chest X-ray, computed tomography/magnetic resonance imaging and histology aided with diagnosis and follow-up. Nine patients underwent cardiac surgery and nine received long-term antiparasitic treatment for a median duration of 25 months (range 4-93 months. One patient died intra-operatively due to cyst rupture and endovascular dissemination. Two patients died 10 and 14 years after diagnosis, due to pulmonary embolism (PE and cardiac failure, respectively. One patient was lost to follow-up. Patients who had cardiac involvement exclusively did not have complications after surgery and were considered cured. There was only one recurrence requiring a second operation. Patients with vena cava involvement developed PEs and presented multiple complications. CONCLUSIONS: Cardiovascular CE is associated with a high risk of potentially lethal complications. Clinical manifestations and complications vary according to cyst location. Isolated cardiac CE may be cured after surgery, while endovascular extracardiac involvement is associated with severe chronic complications. CE should be included in the differential diagnosis of cardiovascular disease in patients from endemic areas.

  7. Drip, Ship, and On-Demand Endovascular Therapy for Acute Ischemic Stroke.

    Directory of Open Access Journals (Sweden)

    Man-Seok Park

    Full Text Available The "drip and ship" approach can facilitate an early initiation of intravenous thrombolysis (IVT for acute ischemic stroke (AIS at community hospitals. New endovascular treatment modalities, such as stent retrieval, have further improved the rate of safe and successful recanalization. We assessed the clinical outcomes of on-demand endovascular therapy in patients with AIS who were transported to a comprehensive stroke center under the "drip and ship" paradigm.This retrospective study evaluated prospectively registered patients with acute large vessel occlusions in the anterior circulation who underwent endovascular recanalization after IVT at our regional comprehensive stroke center between January 2011 and April 2014. Clinical outcomes and neuroradiological findings were compared between patients who received IVT at the center (direct visit, DV and at a community hospital (drip and ship, DS.Baseline characteristics such as age, initial National Institutes of Health Stroke Scale (NIHSS score, and risk factors for stroke were similar, and most patients underwent endovascular therapy with a Solitaire stent (81.9% vs. 89.3% for DV and DS, respectively, P = 0.55. The average initial NIHSS score was 12.15 ± 4.1 (12.06 vs. 12.39 for DV and DS, respectively, P = 0.719. The proportions of long-term favorable outcomes (modified Rankin Scale score ≤ 2 at 90 days and successful recanalization (Thrombolysis in Cerebral Ischemia score ≥ 2b were not significantly different (P = 0.828 and 0.158, respectively. The mortality rates and occurrences of symptomatic intracerebral hemorrhage were not significantly different (P = 0.999 and 0.267, respectively.The "drip and ship" approach with subsequent endovascular therapy is a feasible treatment concept for patients with acute large vessel occlusion in the anterior circulation that could help improve clinical outcomes in patients with AIS.

  8. Vascular training and endovascular practice in Europe

    DEFF Research Database (Denmark)

    Liapis, C.D.; Avgerinos, E.D.; Sillesen, H.

    2009-01-01

    OBJECTIVE: To evaluate the influence of the status of vascular surgery (VS) training paradigms on the actual practice of endovascular therapy among the European countries. METHODS: An email-based survey concerning vascular surgery training models and endovascular practices of different clinical...... specialties was distributed to a VS educator within 14 European countries. European Vascular and Endovascular Monitor (EVEM) data also were processed to correlate endovascular practice with training models. RESULTS: Fourteen questionnaires were gathered. Vascular training in Europe appears in 3 models: 1....... Mono-specialty (independence): 7 countries, 2. Subspecialty: 5 countries, 3. An existing specialty within general surgery: 2 countries. Independent compared to non-independent certification shortens overall training length (5.9 vs 7.9 years, p=0.006), while increasing overall training devoted...

  9. Vascular training and endovascular practice in Europe

    DEFF Research Database (Denmark)

    Liapis, C.D.; Avgerinos, E.D.; Sillesen, H.

    2009-01-01

    specialties was distributed to a VS educator within 14 European countries. European Vascular and Endovascular Monitor (EVEM) data also were processed to correlate endovascular practice with training models. RESULTS: Fourteen questionnaires were gathered. Vascular training in Europe appears in 3 models: 1....... Mono-specialty (independence): 7 countries, 2. Subspecialty: 5 countries, 3. An existing specialty within general surgery: 2 countries. Independent compared to non-independent certification shortens overall training length (5.9 vs 7.9 years, p=0.006), while increasing overall training devoted......% respectively. Countries with independent vascular certification, despite their lower average endovascular index (procedures per 100,000 population), reported a higher growth rate of aortic endovascular procedures (VS independent 132% vs VS non-independent 87%), within a four-year period (2003-2007). Peripheral...

  10. Acute vasculitis after endovascular brachytherapy

    International Nuclear Information System (INIS)

    Fajardo L-G, Luis F.; Prionas, Stavros D.; Kaluza, Grzegorz L.; Raizner, Albert E.

    2002-01-01

    Purpose: Angioplasty effectively relieves coronary artery stenosis but is often followed by restenosis. Endovascular radiation (β or γ) at the time of angioplasty prevents restenosis in a large proportion of vessels in swine (short term) and humans (short and long term). Little information is available about the effects of this radiation exposure beyond the wall of the coronary arteries. Methods and Materials: Samples were obtained from 76 minipigs in the course of several experiments designed to evaluate endovascular brachytherapy: 76 of 114 coronary arteries and 6 of 12 iliac arteries were exposed to endovascular radiation from 32 P sources (35 Gy at 0.5 mm from the intima). Two-thirds of the vessels had angioplasty or stenting. The vessels were systematically examined either at 28 days or at 6 months after radiation. Results: We found an unexpected lesion: acute necrotizing vasculitis in arterioles located ≤2.05 mm from the target artery. It was characterized by fibrinoid necrosis of the wall, often associated with lymphocytic exudates or thrombosis. Based on the review of perpendicular sections of tissue samples, the arterioles had received between 6 and 40 Gy. This arteriolar vasculitis occurred at 28 days in samples from 51% of irradiated coronary arteries and 100% of irradiated iliac arteries. By 6 months, the incidence of acute vasculitis decreased to 24% around the coronary arteries. However, at that time, healing vasculitis was evident, often with luminal narrowing, in 46% of samples. Vasculitis was not seen in any of 44 samples from unirradiated vessels (0%) and had no relation to angioplasty, stenting, or their sequelae. This radiation-associated vasculitis in the swine resembles the localized lymphocytic vasculitis that we have reported in tissues of humans exposed to external radiation. On the other hand, it is quite different from the various types of systemic vasculitis that occur in nonirradiated humans. Conclusion: Endoarterial brachytherapy

  11. Endovascular Management of Acute Limb Ischemia.

    LENUS (Irish Health Repository)

    Hynes, Brian G

    2011-09-14

    Despite major advances in pharmacologic and endovascular therapies, acute limb ischemia (ALI) continues to result in significant morbidity and mortality. The incidence of ALI may be as high as 13-17 cases per 100,000 people per year, with mortality rates approaching 18% in some series. This review will address the contemporary endovascular management of ALI encompassing pharmacologic and percutaneous interventional treatment strategies.

  12. Outcomes of fenestrated and branched endovascular repair of complex abdominal and thoracoabdominal aortic aneurysms.

    Science.gov (United States)

    Schanzer, Andres; Simons, Jessica P; Flahive, Julie; Durgin, Jonathan; Aiello, Francesco A; Doucet, Danielle; Steppacher, Robert; Messina, Louis M

    2017-09-01

    More than 80% of infrarenal aortic aneurysms are treated by endovascular repair. However, adoption of fenestrated and branched endovascular repair for complex aortic aneurysms has been limited, despite high morbidity and mortality associated with open repair. There are few published reports of consecutive outcomes, inclusive of all fenestrated and branched endovascular repairs, starting from the inception of a complex aortic aneurysm program. Therefore, we examined a single center's consecutive experience of fenestrated and branched endovascular repair of complex aortic aneurysms. This is a single-center, prospective, observational cohort study evaluating 30-day and 1-year outcomes in all consecutive patients who underwent fenestrated and branched endovascular repair of complex aortic aneurysms (definition: requiring one or more fenestrations or branches). Data were collected prospectively through an Institutional Review Board-approved registry and a physician-sponsored investigational device exemption clinical trial (G130210). We performed 100 consecutive complex endovascular aortic aneurysm repairs (November 2010 to March 2016) using 58 (58%) commercially manufactured custom-made devices and 42 (42%) physician-modified devices to treat 4 (4%) common iliac, 42 (42%) juxtarenal, 18 (18%) pararenal, and 36 (36%) thoracoabdominal aneurysms (type I, n = 1; type II, n = 4; type III, n = 12; type IV, n = 18; arch, n = 1). The repairs included 309 fenestrations, branches, and scallops (average of 3.1 branch arteries/case). All patients had 30-day follow-up for 30-day event rates: three (3%) deaths; six (6%) target artery occlusions; five (5%) progressions to dialysis; eight (8%) access complications; one (1%) paraparesis; one (1%) bowel ischemia; and no instances of myocardial infarction, paralysis, or stroke. Of 10 type I or type III endoleaks, 8 resolved (7 with secondary intervention, 1 without intervention). Mean follow-up time was 563 days (interquartile range

  13. [Macroscopic hematuria secondary to nutcracker syndrome and successful endovascular treatment].

    Science.gov (United States)

    Hinojosa, Carlos A; Anaya-Ayala, Javier E; Boyer-Duck, Estefanía; Laparra-Escareno, Hugo; Torres-Machorro, Adriana; Lizola, Rene

    2017-12-01

    Nutcracker syndrome is a rare entity, and in the majority of cases is the result of extrinsic compression of the left renal vein between the superior mesenteric artery and the aorta, associated with functional stenosis. To present the case of a 19-year-old female with no significant medical history with confirmed diagnosed of nutcracker syndrome treated successfully by endovascular means. She was referred to the Vascular Surgery Department with a 6-month history of macroscopic haematuria, after other aetiologies were ruled out. Abdominal computed tomography angiography revealed compression of the left renal vein; the patient underwent endovascular treatment, and a 12×16 mm balloon expandable stent was placed with immediate angiographic improvement, decreased pressure gradients and progressive resolution of haematuria. At one year, she remains symptom-free. Nutcracker syndrome is uncommon, and a high index of suspicion is needed. Macroscopic haematuria is not always present, and in our case stent placement demonstrated effectiveness in the resolution of symptoms at 12 months' follow--up. We also present a brief review of the literature. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  14. Suprarenal fixation barbs can induce renal artery occlusion in endovascular aortic aneurysm repair.

    Science.gov (United States)

    Subedi, Shree K; Lee, Andy M; Landis, Gregg S

    2010-01-01

    Renal artery occlusion following endovascular abdominal aortic aneurysm repair with suprarenal fixation is uncommon. We report one patient who was found to develop renal artery occlusion and parenchymal infarction 6 months after repair using an endovascular graft with suprarenal fixation. Our patient underwent emergent endovascular repair of a symptomatic 6 cm abdominal aortic aneurysm. The covered portion of the endograft was inadvertently deployed well below the renal artery orifices. At the completion of the procedure both renal arteries were confirmed to be patent. One month postoperatively, a computed tomographic (CT) scan showed exclusion of the aortic sac and normal enhancement of both kidneys. At 6 months, the patient was found to have elevated serum creatinine levels despite having no clinical symptoms. CT scanning revealed a nonenhancing left kidney, and angiography demonstrated an occlusion of the left renal artery. A barb welded to the bare metal stent appeared to be impinging on the renal artery. We believe that renal artery occlusion after endovascular repair can occur due to repetitive injury to the renal artery orifice from barbs welded to the bare metal stent. To our knowledge, this is the first reported case of renal artery occlusion caused by repetitive injury from transrenal fixation systems. Copyright 2010 Annals of Vascular Surgery Inc. Published by Elsevier Inc. All rights reserved.

  15. Aneurysmal wall enhancement and perianeurysmal edema after endovascular treatment of unruptured cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Su, I. Chang [Toronto Western Hospital, Division of Neuroradiology, Department of Medical Imaging, Toronto, ON (Canada); Taipei Cathay General Hospital, Division of Neurosurgery, Department of Surgery, Taipei (China); Willinsky, Robert A.; Agid, Ronit [Toronto Western Hospital, Division of Neuroradiology, Department of Medical Imaging, Toronto, ON (Canada); Fanning, Noel F. [Cork University Hospital, Department of Interventional Neuroradiology, Cork (Ireland)

    2014-06-15

    Perianeurysmal edema and aneurysm wall enhancement are previously described phenomenon after coil embolization attributed to inflammatory reaction. We aimed to demonstrate the prevalence and natural course of these phenomena in unruptured aneurysms after endovascular treatment and to identify factors that contributed to their development. We performed a retrospective analysis of consecutively treated unruptured aneurysms between January 2000 and December 2011. The presence and evolution of wall enhancement and perianeurysmal edema on MRI after endovascular treatment were analyzed. Variable factors were compared among aneurysms with and without edema. One hundred thirty-two unruptured aneurysms in 124 patients underwent endovascular treatment. Eighty-five (64.4 %) aneurysms had wall enhancement, and 9 (6.8 %) aneurysms had perianeurysmal brain edema. Wall enhancement tends to persist for years with two patterns identified. Larger aneurysms and brain-embedded aneurysms were significantly associated with wall enhancement. In all edema cases, the aneurysms were embedded within the brain and had wall enhancement. Progressive thickening of wall enhancement was significantly associated with edema. Edema can be symptomatic when in eloquent brain and stabilizes or resolves over the years. Our study demonstrates the prevalence and some appreciation of the natural history of aneurysmal wall enhancement and perianeurysmal brain edema following endovascular treatment of unruptured aneurysms. Aneurysmal wall enhancement is a common phenomenon while perianeurysmal edema is rare. These phenomena are likely related to the presence of inflammatory reaction near the aneurysmal wall. Both phenomena are usually asymptomatic and self-limited, and prophylactic treatment is not recommended. (orig.)

  16. Aneurysmal wall enhancement and perianeurysmal edema after endovascular treatment of unruptured cerebral aneurysms

    International Nuclear Information System (INIS)

    Su, I. Chang; Willinsky, Robert A.; Agid, Ronit; Fanning, Noel F.

    2014-01-01

    Perianeurysmal edema and aneurysm wall enhancement are previously described phenomenon after coil embolization attributed to inflammatory reaction. We aimed to demonstrate the prevalence and natural course of these phenomena in unruptured aneurysms after endovascular treatment and to identify factors that contributed to their development. We performed a retrospective analysis of consecutively treated unruptured aneurysms between January 2000 and December 2011. The presence and evolution of wall enhancement and perianeurysmal edema on MRI after endovascular treatment were analyzed. Variable factors were compared among aneurysms with and without edema. One hundred thirty-two unruptured aneurysms in 124 patients underwent endovascular treatment. Eighty-five (64.4 %) aneurysms had wall enhancement, and 9 (6.8 %) aneurysms had perianeurysmal brain edema. Wall enhancement tends to persist for years with two patterns identified. Larger aneurysms and brain-embedded aneurysms were significantly associated with wall enhancement. In all edema cases, the aneurysms were embedded within the brain and had wall enhancement. Progressive thickening of wall enhancement was significantly associated with edema. Edema can be symptomatic when in eloquent brain and stabilizes or resolves over the years. Our study demonstrates the prevalence and some appreciation of the natural history of aneurysmal wall enhancement and perianeurysmal brain edema following endovascular treatment of unruptured aneurysms. Aneurysmal wall enhancement is a common phenomenon while perianeurysmal edema is rare. These phenomena are likely related to the presence of inflammatory reaction near the aneurysmal wall. Both phenomena are usually asymptomatic and self-limited, and prophylactic treatment is not recommended. (orig.)

  17. Indication of endovascular treatment of type B aortic dissection - Literature review

    Science.gov (United States)

    Duarte, João Jackson; Pontes, José Carlos Dorsa Vieira; Benfatti, Ricardo Adala; Ferrachini, Adriana Lugo; Karakhanian, Walter Kegham; Razuk Filho, Álvaro

    2014-01-01

    Aortic dissection is a cardiovascular event of high mortality if not early diagnosed and properly treated. In Stanford type A aortic dissection, there is the involvement of the ascending aorta, whereas in type B the ascending aorta is not affected. The treatment of type A aortic dissection is mainly surgical. The hospital mortality of type B aortic dissection surgical treatment is approximately 20%, while medical therapy is 10%. However, half the patients who are discharged from hospital after medical treatment, progress to aortic complications in the following years, and the mortality in three to five years may reach 25-50%. In addition, the surgical treatment of aortic complications after medical treatment, has also a significant mortality. This way, the endovascular treatment comes up as an interesting alternative of a less invasive treatment for this disease. They presented a mortality rate lower than 10% with more than 80% success rate of occlusion and thrombosis of the false lumen. The INSTEAD TRIAL, which randomized patients with uncomplicated type B aortic dissection for optimal medical therapy and endovascular treatment in addition to optimal medical therapy, showed that after three years of follow up, patients who underwent endovascular treatment had lower mortality and aorta-related complications. Therefore, there is a current tendency to recommend the endovascular treatment as a standard for the treatment of type B aortic dissection PMID:25372915

  18. Early inflammatory response following elective abdominal aortic aneurysm repair: A comparison between endovascular procedure and conventional, open surgery

    Directory of Open Access Journals (Sweden)

    Marjanović Ivan

    2011-01-01

    Full Text Available Background/Aim. Abdominal aorta aneurysm (AAA represents a pathological enlargment of infrarenal portion of aorta for over 50% of its lumen. The only treatment of AAA is a surgical reconstruction of the affected segment. Until the late XX century, surgical reconstruction implied explicit, open repair (OR of AAA, which was accompanied by a significant morbidity and mortality of the treated patients. Development of endovascular repair of (EVAR AAA, especially in the last decade, offered another possibility of surgical reconstruction of AAA. The preliminary results of world studies show that complications of such a procedure, as well as morbidity and mortality of patients, are significantly lower than with OR of AAA. The aim of this paper was to present results of comparative clinical prospective study of early inflammatory response after reconstruction of AAA between endovascular and open, conventional surgical technique. Methods. A comparative clinical prospective study included 39 patients, electively operated on for AAA within the period of December 2008 - February 2010, divided into two groups. The group I counted 21 (54% of the patients, 58-87 years old (mean 74.3 years, who had been submited to EVAR by the use of excluder stent graft. The group II consisted of 18 (46% of the patients, 49-82 (mean 66.8 years, operated on using OR technique. All of the treated patients in both groups had AAA larager than 50 mm. The study did not include patients who have been treated as urgent cases, due to the rupture or with simptomatic AAA. Clinical, biochemical and inflamatory parameters in early postoperative period were analyzed, in direct postoperative course (number of leucocytes, thrombocytes, serum circulating levels of cytokine - interleukine (IL-2, IL-4, IL-6 and IL-10. Parameters were monitored on the zero, first, second, third and seventh postoperative days. The study was approved by the Ethics Commitee of the Military Medical Academy. Results

  19. Endovascular Treatment of Incoercible Epistaxis and Epidural Cerebral Hematoma

    Science.gov (United States)

    Bortoluzzi, M.; Pavia, M.

    2006-01-01

    Summary A young patient with a facial trauma after a road accident was admitted to our department with incoercible epistaxis. A CT scan showed a right pterional acute epidural hematoma (EDH). Angiography demonstrated multiple sources of bleeding of the right sphenopalatine arteries, cause of the epistaxis, and an intracranial leakage of the right middle meningeal artery, responsible for the EDH. The patient immediately underwent embolization of the right internal maxillary artery and right middle meningeal artery. The procedure stopped the epistaxis and no further enlargement of the EDH was observed, avoiding its surgical treatment. Endovascular surgery may be an effective procedure to stop the arterial meningeal bleeding sustaining acute EDH and may be a useful tool in the management of special cases of post traumatic EDH. PMID:20569576

  20. Feasibility of Endovascular Radiation Therapy Using Holmium-166 Filled Balloon Catheter in a Swine Hemodialysis Fistula Model: Preliminary Results

    Energy Technology Data Exchange (ETDEWEB)

    Won, Jong Yun; Lee, Kwang Hun; Lee, Do Yun [Dept. of Radiology, Research Institute of Radiological Science, Yensei University College of Medicine, Seoul (Korea, Republic of); Kim, Myoung Soo [Dept. of Radiology, Yensei University College of Medicine, Seoul (Korea, Republic of); Kang, Byung Chul [Dept. of Radiology, Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of); Kim, Seung Jung [Dept. of Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of)

    2011-08-15

    To describe how to make a swine hemodialysis fistula model and report our initial experience to test the feasibility of endovascular radiation therapy with Holmium-166 filled balloon catheters. The surgical formation of arterio-venous fistula (AVF) was performed by end-to-side anastomosis of the bilateral jugular vein and carotid artery of 6 pigs. After 4 weeks, angiograms were taken and endovascular radiation was delivered to the venous side of AVF with Holmium-166 filled balloon catheters. Pigs were sacrificed 4 weeks after the radiation and AVFs were harvested for histological examination. All animals survived without any morbidity during the experimental periods. The formation of fistula on the sides of necks was successful in 11 of the 12 pigs (92%). One AVF failed from the small jugular vein. On angiograms, 4 of the 11 AVFs showed total occlusion or significant stenosis and therefore, endovascular radiation could not be performed. Of 7 eligible AVFs, five underwent successful endovascular radiation and two AVFs did not undergo radiation for the control. Upon histologic analysis, one non-radiated AVF showed total occlusion and others showed intimal thickening from the neointimal hyperplasia. Formation of the swine carotid artery-jugular vein hemodialysis fistula model was successful. Endovascular radiation using a Holmium-166 filled balloon catheter was safe and feasible.

  1. The incidence of contrast medium-induced nephropathy following endovascular aortic aneurysm repair: assessment of risk factors.

    Science.gov (United States)

    Guneyli, Serkan; Bozkaya, Halil; Cinar, Celal; Korkmaz, Mehmet; Duman, Soner; Acar, Turker; Akin, Yigit; Parildar, Mustafa; Oran, Ismail

    2015-05-01

    The aim of the study was to investigate the incidence of contrast medium-induced nephropathy (CIN) and risk factors for CIN following endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair. After exclusion criteria, 139 (121 males, 18 females) patients aged 20-86 (median 65.5) years who underwent endovascular aortic aneurysm repair between January 2002 and September 2013 were included in this retrospective study. CIN, with ≥25% increase in serum creatinine levels within 3 days after contrast medium administration, was compared to the patients' demographics, risk factors, type and complexity of the endovascular operation, parameters regarding to the contrast medium, preoperative estimated glomerular filtration rate (eGFR), and preoperative and early postoperative serum parameters. Statistical analyses were performed with Kolmogorov-Smirnov, χ (2) and Student's t tests. CIN, detected in 39 of 139 patients (28%), was correlated with preoperative eGFR <60 ml/min/1.73 m(2) (P = 0.04) and high preoperative and postoperative serum urea and creatinine levels. Postoperative serum urea levels (P < 0.001) were significant in multivariate analysis. In patients undergoing endovascular aortic aneurysm repair, CIN was correlated with preoperative and postoperative renal impairment, while it was not correlated with the contrast medium dose.

  2. Predictors of Reintervention After Endovascular Repair of Isolated Iliac Artery Aneurysm

    International Nuclear Information System (INIS)

    Zayed, Hany A.; Attia, Rizwan; Modarai, Bijan; Clough, Rachel E.; Bell, Rachel E.; Carrell, Tom; Sabharwal, Tarun; Reidy, John; Taylor, Peter R.

    2011-01-01

    The objective of this study was to identify factors predicting the need for reintervention after endovascular repair of isolated iliac artery aneurysm (IIAA). We reviewed prospectively collected database records of all patients who underwent endovascular repair of IIAA between 1999 and 2008. Detailed assessment of the aneurysms was performed using computed tomography angiography (CTA). Follow-up protocol included CTA at 3 months. If this showed no complication, then annual duplex scan was arranged. Multivariate analysis and analysis of patient survival and freedom from reintervention were performed using Kaplan–Meier life tables. Forty IIAAs (median diameter 44 mm) in 38 patients were treated (all men; median age 75 years), and median follow-up was 27 months. Endovascular repair of IIAA was required in 14 of 40 aneurysms (35%). The rate of type I endoleak was significantly higher with proximal landing zone (PLZ) diameter >30 mm in the aorta or >24 mm in the common iliac artery or distal landing zone (DLZ) diameter >24 mm (P = 0.03, 0.03, and 0.0014, respectively). Reintervention rate (RR) increased significantly with increased diameter or decreased length of PLZ; increased DLZ diameter; and endovascular IIAA repair (P = 0.005, 0.005, 0.02, and 0.02 respectively); however, RR was not significantly affected by length of PLZ or DLZ. Freedom-from-reintervention was 97, 93, and 86% at 12, 24, and 108 months. There was no in-hospital or aneurysm-related mortality. Endovascular IIAA repair is a safe treatment option. Proper patient selection is essential to decrease the RR.

  3. Clinical outcome after endovascular coil embolization in elderly patients with subarachnoid hemorrhage

    International Nuclear Information System (INIS)

    Johansson, M.; Cesarini, K.G.; Ronne-Engstroem, E.; Enblad, P.; Norbaeck, O.; Gal, G.; Tovi, M.; Solander, S.; Contant, C.F.

    2004-01-01

    Subarachnoid hemorrhage (SAH) is not an unusual disease in an elderly population. The clinical outcome has improved over time. It has been suggested that elderly SAH patients would benefit from endovascular aneurysm treatment. The aim of this study was to evaluate technical results and clinical outcome in a series of elderly SAH-patients treated with endovascular coil embolization. Sixty-two patients (≥ 65 years) presenting with aneurysmal SAH underwent early endovascular coil embolization at Uppsala University Hospital between September 1996 and December 2000. In all 62 cases included in the study, endovascular coil embolization was considered the first line of treatment. Admission variables, specific information on technical success, degree of occlusion and procedural complications, and outcome figures were recorded. Clinical grade on admission was Hunt and Hess (H and H) I-II in 39%, H and H III in 27% and H and H IV-V in 34% of the patients. The proportion of posterior circulation aneurysms was 24%. Coil embolization was successfully completed in 94%. The degree of occlusion of the treated aneurysm was complete occlusion in 56%, neck remnant in 21%, residual filling in 11%, other remnant in 5% and not treated in 6%. The rate of procedural complications was 11%. Outcome after 6 months was favorable in 41%, severe disability in 36% and poor in 22%. Favorable outcome was achieved in 57% of the H and H I-II patients, 47% of the H and H III patients and 17% of the H and H IV-V patients. Endovascular aneurysm treatment can be performed in elderly patients with SAH with a high level of technical success, acceptable aneurysm occlusion results, an acceptable rate of procedural complications and fair outcome results. (orig.)

  4. Percutaneous Transabdominal Approach for the Treatment of Endoleaks after Endovascular Repair of Infrarenal Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sun Young; Lee, Do Yun; Lee, Kwang Hun [Severance Hospital, University of Yonsei, Seoul (Korea, Republic of); Won, Jong Yun [Gangnam Severance Hospital, University of Yonsei, Seoul (Korea, Republic of); Choi, Dong Hoon; Shim, Won Heum [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2010-02-15

    The purpose of this study was to evaluate the technical feasibility and clinical efficacy of percutaneous transabdominal treatment of endoleaks after endovascular aneurysm repair. Between 2000 and 2007, six patients with type I (n = 4) or II (n = 2) endoleaks were treated by the percutaneous transabdominal approach using embolization with N-butyl cyanoacrylate with or without coils. Five patients underwent a single session and one patient had two sessions of embolization. The median time between aneurysm repair and endoleak treatment was 25.5 months (range: 0-84 months). Follow-up CT images were evaluated for changes in the size and shape of the aneurysm sac and presence or resolution of endoleaks. The median follow-up after endoleak treatment was 16.4 months (range: 0-37 months). Technical success was achieved in all six patients. Clinical success was achieved in four patients with complete resolution of the endoleak confirmed by follow-up CT. Clinical failure was observed in two patients. One eventually underwent surgical conversion, and the other was lost to follow-up. There were no procedure-related complications. The percutaneous transabdominal approach for the treatment of type I or II endoleaks, after endovascular aneurysm repair, is an alternative method when conventional endovascular methods have failed.

  5. Evaluation of diffusion-perfusion mismatch for determining indication for emergency endovascular revascularization

    International Nuclear Information System (INIS)

    Masuda, Atsushi; Miki, Takanori; Matsumoto, Hiroaki

    2010-01-01

    We evaluated the usefulness of assessing by diffusion-perfusion mismatch (D/P mismatch) whether there is adaptation of neuroendovascular revascularization for acute ischemic stroke out of intravenous tissue plasminogen activator (IV t-PA). We retrospectively analyzed 24 patients who underwent D/P mismatch and endovascular treatment between October 2005 and September 2008. This investigation included stroke patients with a National Institutes of Health Stroke Scale (NIHSS) score less than 4. Sixteen acute ischemic stroke patients had an NIHSS score greater than 5. Eight patients (50%) had a favorable neurological outcome (modified Rankin Scale 0 to 2). Eight acute ischemic stroke patients had an NIHSS score equal to or less than 4. Four patients who underwent emergency endovascular treatment on admission had a favorable neurological outcome, but 3 patients treated for progressive stroke after admission all had a poor prognosis. Evaluating D/P mismatch was useful for determining the adaptation of emergency neuroendovascular revascularization for acute ischemic stroke out of IV t-PA. Acute ischemic stroke patients with an NIHSS score equal to or less than 4 and diffusion/perfusion mismatch need careful observation to enable endovascular treatment immediately after progressive stroke. (author)

  6. Neck diameter and inner curve seal zone predict endograft-related complications in highly angulated necks after endovascular aneurysm repair using the Aorfix endograft.

    Science.gov (United States)

    Wang, Sophie; Hicks, Caitlin W; Malas, Mahmoud B

    2018-03-01

    Many studies have found that preoperative aneurysm anatomy can determine the postoperative complication rates for endovascular aneurysm repair (EVAR). With continual improvement in endograft technology, patients with challenging anatomy are increasingly able to undergo successful treatment with EVAR. This study aimed to quantify the influence of proximal neck anatomy on contemporary outcomes in a cohort of abdominal aortic aneurysm patients with highly angulated aneurysm necks. The study included 205 patients originally enrolled in the Prospective Aneurysm Trial: High Angle Aorfix Bifurcated Stent Graft (PYTHAGORAS) trial, the largest study to date to enroll patients with aortic aneurysm neck angles >60 degrees. Anatomic parameters included measurements of the proximal aneurysm neck as well as seal zones modeled in preoperative computed tomography scans. Follow-up up to 5 years postoperatively was available, for which stent-related complications (defined as sac expansion, stent migration, and type Ia endoleak) were assessed. Predictive anatomic parameters were assessed by Cox regression models, and a final multivariate model was created to predict complications. The cohort was also stratified by neck diameter for further comparison of complication rates. Of 205 patients enrolled in the trial, 67 stent-related complications occurred in 36 patients (17.6%) at 5 years after EVAR. Median follow-up was 48 months. Demographic and medical comorbidities did not predict risk of complications, nor did proximal neck length or neck angle. Independent predictors of post-EVAR complications included increasing proximal neck diameter (hazard ratio, 1.14; 95% confidence interval, 1.03-1.27; P < .05) and decreasing seal zone inner curve length (hazard ratio, 1.03; 95% confidence interval, 1.01-1.06; P < .05), which yielded a fair discriminatory utility (concordance, 0.67). Stratification by median neck diameter of 22.5 mm yielded two groups; patients with larger aortic necks

  7. Source of errors and accuracy of a two-dimensional/three-dimensional fusion road map for endovascular aneurysm repair of abdominal aortic aneurysm.

    Science.gov (United States)

    Kauffmann, Claude; Douane, Frédéric; Therasse, Eric; Lessard, Simon; Elkouri, Stephane; Gilbert, Patrick; Beaudoin, Nathalie; Pfister, Marcus; Blair, Jean François; Soulez, Gilles

    2015-04-01

    To evaluate the accuracy and source of errors using a two-dimensional (2D)/three-dimensional (3D) fusion road map for endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm. A rigid 2D/3D road map was tested in 16 patients undergoing EVAR. After 3D/3D manual registration of preoperative multidetector computed tomography (CT) and cone beam CT, abdominal aortic aneurysm outlines were overlaid on live fluoroscopy/digital subtraction angiography (DSA). Patient motion was evaluated using bone landmarks. The misregistration of renal and internal iliac arteries were estimated by 3 readers along head-feet and right-left coordinates (z-axis and x-axis, respectively) before and after bone and DSA corrections centered on the lowest renal artery. Iliac deformation was evaluated by comparing centerlines before and during intervention. A score of clinical added value was estimated as high (z-axis 5 mm). Interobserver reproducibility was calculated by the intraclass correlation coefficient. The lowest renal artery misregistration was estimated at x-axis = 10.6 mm ± 11.1 and z-axis = 7.4 mm ± 5.3 before correction and at x-axis = 3.5 mm ± 2.5 and z-axis = 4.6 mm ± 3.7 after bone correction (P = .08), and at 0 after DSA correction (P artery was estimated at x-axis = 2.4 mm ± 2.0 and z-axis = 2.2 mm ± 2.0. Score of clinical added value was low (n = 11), good (n= 0), and high (n= 5) before correction and low (n = 5), good (n = 4), and high (n = 7) after bone correction. Interobserver intraclass correlation coefficient for misregistration measurements was estimated at 0.99. Patient motion before stent graft delivery was estimated at x-axis = 8 mm ± 5.8 and z-axis = 3.0 mm ± 2.7. The internal iliac artery misregistration measurements were estimated at x-axis = 6.1 mm ± 3.5 and z-axis = 5.6 mm ± 4.0, and iliac centerline deformation was estimated at 38.3 mm ± 15.6. Rigid registration is feasible and fairly accurate. Only a partial reduction of vascular

  8. Endovascular therapy of abdominal aortic aneurysm: results of a mid-term follow-up; Endovaskulaere Therapie von abdominellen Aortenaneurysmen: Klinisch-radiologishe Ergebnisse im mittelfristigen Verlauf

    Energy Technology Data Exchange (ETDEWEB)

    Pitton, M.B.; Schweitzer, H.; Herber, S.; Thelen, M. [Universitaetsklinik Mainz (Germany). Klinik fuer Radiologie; Schmiedt, W.; Neufang, A. [Universitaetsklinik Mainz (Germany). Klinik fuer Herz-, Thorax-, und Gefaesschirurgie; Dueber, C. [Universitaetsklinikum Mannheim (Germany). Inst. fuer Diagnostische Radiologie

    2003-10-01

    Prospective study to evaluate clinical results and complications of endovascular abdominal aortic aneurysm treatment in a mid-term follow-up. Materials and methods: A total of 122 patients (9 females, 113 males, average age 70.0{+-}7,9 years) with abdominal aortic aneurysms were treated with stent grafts (53 Vanguard or Stentor endografts, 69 Talent endografts). Group I consisted of 40 patients who had all aortic tributaries of the aneurysm sac occluded prior to endovalscular grafting, either spontaneously by parietal thrombosis or by selective coil embolization of the respective ostia preserving collateral circulation distal to the vessel occlusion. Group II consisted of 82 patients and included all cases without or with incomplete coil embolization with at least one patent vessel. Stent grafting was performed in general anesthesia in the first 21 patients, followed by peridural anesthesia in 15 cases, and local anesthesia with conscious sedation in 86 cases. The results were evaluated with Spiral-CT, MRI and radiographs of the endovascular graft, with follow-up examinations obtained at 3, 6, 12 months, and every year - Implantation was successfully completed in all cases without primary conversion surgery, laparotomy or any significant complication. Mean follow-up was 29{+-}21 months (maximum 82 months). The 30-day mortality was 0,8% due to a myocardial infarction 3 days after discharge from the hospital. A total of 47 re-interventions were performed in 29 patients (23.8%), with 35 re-interventions in 18 cases with Vanguard or Stentor endografts and 12 re-interventions in 11 patients with Talent endografts. 23 percutaneous re-interventions included distal graft extension (n=11), Wallstent for kinking and limb stenosis (n=3), and secondary coil embolization of collateral vessels (n=9). 24 surgical re-interventions included proximal graft extension (n=6), new endovascular grafts (n=3), surgical clipping of lumbar and mesenteric artery branches for type-II endoleaks

  9. Endovascular Treatment of a Gastroduodenal Artery Pseudoaneurysm Rupture after a Car Accident

    Directory of Open Access Journals (Sweden)

    Sofia Dutra

    2017-09-01

    Full Text Available The authors present a case of a 39-year-old man with alcoholic chronic pancreatitis that was admitted in the emergency department after a car accident, complaining of abdominal pain and looking pale. The patient was hemodinamically unstable, requiring blood transfusions. He underwent computed tomography angiogram of the abdomen and pelvis, showing a pseudoaneurysm of the gastroduodenal artery and a hemoperitoneum. He was referred to our interventional radiology unit and submitted to endovascular treatment, consisting of ‘backdoor’ and ‘frontdoor’ embolization of the gastroduodenal artery and pseudoaneurysm neck with coils, with total exclusion in control angiography. With this case description we intend to highlight the rarity of the pseudoaneurysm rupture of the gastroduodenal artery and to emphasize the importance of an interventional radiology response that had a fundamental role in the endovascular treatment, in an emergency context.

  10. Diabetic Foot Limb Salvage-A Series of 809 Attempts and Predictors for Endovascular Limb Salvage Failure.

    Science.gov (United States)

    Lo, Zhiwen Joseph; Lin, Zhimin; Pua, Uei; Quek, Lawrence Han Hwee; Tan, Bien Ping; Punamiya, Sundeep; Tan, Glenn Wei Leong; Narayanan, Sriram; Chandrasekar, Sadhana

    2018-02-09

    To review patient characteristics and outcomes of in-patient diabetic foot limb salvage and identify risk factors predicting for endovascular limb salvage failure. Retrospective study of limb salvage attempts in 809 patients between August 2013 and July 2015. Sixty-eight percent of our study population were male with mean age at 65 years and 73% presented with Rutherford grade 6 critical limb ischemia, with the remaining 27% Rutherford grade 5. Eighty-one percent had toe pressures of less than 50 mm Hg, 64% had infrainguinal trans-Atlantic inter-society consensus (TASC II) C or D lesions while 78% had infrapopliteal TASC II C or D lesions. Seven hundred seventy-seven patients (96%) underwent endovascular-first approach limb salvage, with 95% requiring infrapopliteal angioplasty, with 84% of them requiring 2-vessel or 3-vessel revascularization. Thirty-two patients (4%) underwent surgical bypass limb salvage, with 63% performed as salvage procedures for failed angioplasties. The mean in-patient stay was 12.3 days within the endovascular group and 31.1 days within the bypass group (P diabetic foot peripheral arterial disease presented with Rutherford grade 6 disease, with mostly TASC II C or D lesions and required infrapopliteal revascularization. As most patients had multiple comorbidities and were poor surgical candidates, the majority underwent endovascular-first approach revascularization. Independent predictors of endovascular limb salvage failure include ESRF, toe pressures <50 mm Hg, infrainguinal TASC II patterns C or D, and indirect angiosome revascularization. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Endovascular treatment for intracranial venous sinus thrombosis

    International Nuclear Information System (INIS)

    Zhang Qiang; Li Shenmao; Ji Xunming; Miao Zhongrong; Zhu Fengshui; Zhi Xinglong; Ling Feng

    2007-01-01

    Objective: To evaluate the efficacy and risk of endovascular treatment for intracranial venous sinus thrombosis. Methods: Twenty seven patients with intracranial venous sinus thrombosis confirmed by CT, MRI, MRV and/or DSA, from 2004 September to 2006 September, were treated with anticoagulant therapy but without response and then followed by multiple modalities including endovascular treatment. Nineteen of them accepted intravenous thrombolysis and mechanical thrombus maceration, another 5 accepted intravenous thrombolysis, mechanical thrombus maceration and intraarterial thrombolysis and the last 3 with stenting. Results: After thrombolysis, symptoms and signs of 23 patients improved obviously and headache disappeared in 18 of them, but with only mild degree in other 5 and no improvement in 3. Twenty one patients among them achieved recanalization of sinuses completely as confirmed on postprocedural angiography, MRI and MRV studies taken prior to hospital discharge and other 3 achieved recanalization of sinuses partly. Conclusion: Endovascular treatment is an effective and safe measure for potentially catastrophic intracranial dural sinus thrombosis. (authors)

  12. Perioperative complications in endovascular neurosurgery: Anesthesiologist's perspective

    Science.gov (United States)

    Sharma, Megha U.; Ganjoo, Pragati; Singh, Daljit; Tandon, Monica S.; Agarwal, Jyotsna; Sharma, Durga P.; Jagetia, Anita

    2017-01-01

    Background: Endovascular neurosurgery is known to be associated with potentially serious perioperative complications that can impact the course and outcome of anesthesia. We present here our institutional experience in the anesthetic management of various endovascular neurosurgical procedures and their related complications over a 10-year period. Methods: Data was obtained in 240 patients pertaining to their preoperative status, details of anesthesia and surgery, perioperative course and surgery-related complications. Information regarding hemodynamic alterations, temperature variability, fluid-electrolyte imbalance, coagulation abnormalities and alterations in the anesthesia course was specifically noted. Results: Among the important complications observed were aneurysm rupture (2.5%), vasospasm (6.67%), thromboembolism (4.16%), contrast reactions, hemodynamic alterations, electrolyte abnormalities, hypothermia, delayed emergence from anesthesia, groin hematomas and early postoperative mortality (5.14%). Conclusion: Awareness of the unique challenges of endovascular neurosurgery and prompt and appropriate management of the associated complications by an experienced neuroanesthesiologist is vital to the outcome of these procedures. PMID:28413524

  13. A case that underwent bilateral video-assisted thoracoscopic ...

    African Journals Online (AJOL)

    No Abstract Available A case that underwent bilateral video-assisted thoracoscopic surgical (VATS) biopsy combined with pneumonectomy is presented. The patient developed hypoxia during the contralateral VATS biopsy. His hypoxia was treated with positive expiratory pressure (PEEP) to the dependent lung and apneic ...

  14. EVAR: Benefits of CEUS for monitoring stent-graft status

    Energy Technology Data Exchange (ETDEWEB)

    Cantisani, Vito, E-mail: vito.cantisani@uniroma1.it [Department of Radiological, Oncological and Anatomo-Pathological Sciences, Università Sapienza di Roma, Policlinico Umberto I, Rome (Italy); Grazhdani, Hektor [Department of Radiological, Oncological and Anatomo-Pathological Sciences, Università Sapienza di Roma, Policlinico Umberto I, Rome (Italy); Clevert, Dirk-André [Interdisciplinary Ultrasound Center, Munich University, Hospital Grosshadern, Munich (Germany); Iezzi, Roberto [Policlinico A. Gemelli, Catholic University, Rome (Italy); Aiani, Luca; Martegani, Alberto [Ospedale Valduce, Como (Italy); Fanelli, Fabrizio; Di Marzo, Luca; Wlderk, Andrea; Cirelli, Carlo; Catalano, Carlo; Di Leo, Nicola; Di Segni, Mattia; Malpassini, Flavio; D’Ambrosio, Ferdinando [Department of Radiological, Oncological and Anatomo-Pathological Sciences, Università Sapienza di Roma, Policlinico Umberto I, Rome (Italy)

    2015-09-15

    Highlights: • In the last two decades several studies have shown the role of contrast enhanced ultrasound [CEUS] in post-EVAR surveillance, with very good diagnostic performance, absence of renal impairment, and no radiation, accompanied by low costs, in comparison with CTA. • In numerous prospective studies and meta-analyses the detection and characterization of endoleaks with CEUS is comparable to that of CTA imaging. • Nowadays in the EVAR surveillance novel strategies which involve CEUS with a central role, are suggested by several authors and applied in many institutions. • CEUS technique, findings, diagnostic accuracy, and its role in the follow up program are discussed in this review article. - Abstract: Endo vascular aortic repair [EVAR] is performed with low peri-operative morbidity and mortality rate and short hospital stay. However, EVAR needs a close and lifelong imagining surveillance for a timely detection of possible complications including endoleaks, graft migration, fractures, and enlargement of aneurysm sac size with eventual rupture. Contrast enhanced computed tomography [CTA] is actually considered the gold-standard in EVAR follow-up, but it is accompanied with radiation burden and renal injury due to the use of contrast media. In the last two decades several studies have shown the role of contrast enhanced ultrasound [CEUS] in post-EVAR surveillance, with very good diagnostic performance, absence of renal impairment, and no radiation, accompanied by low costs, in comparison with CTA. In numerous prospective studies and meta-analyses the detection and characterization of endoleaks with CEUS is comparable to that of CTA imaging. Nowadays, in the EVAR surveillance novel strategies which involve CEUS with a central role, are suggested by several authors and applied in many institutions. In this review article we will present a comprehensive overview and analyses of the literature on the CEUS state-of-art imagining of EVAR follow-up, with its technique, findings, diagnostic accuracy, and its role in the follow up program.

  15. Outcomes of surgical versus endovascular repair of unruptured brain aneurysms in individuals aged ≥ 75 years.

    Science.gov (United States)

    Inamasu, Joji; Tanaka, Teppei; Sadato, Akiyo; Hayakawa, Motoharu; Adachi, Kazuhide; Hayashi, Takuro; Kato, Yoko; Hirose, Yuichi

    2014-10-01

    Therapeutic intervention to repair unruptured aneurysms (UA) has not been strongly recommended for the elderly, because of their limited life expectancy and low annual bleeding rate. However, physically and mentally healthy older adults with seemingly high risk of aneurysmal bleeding might benefit from having their UA repaired. A single-center retrospective study was carried out. Among 1078 patients admitted for treatment of UA between 2007 and 2011, the number of patients aged ≥ 75 years who underwent surgical and endovascular repair of UA was 30 and 31, respectively. The operative and mid-term outcomes were compared between the two groups. For evaluation of the operative outcomes, frequency and types of adverse events that occurred within 30 days of intervention (operative morbidity) were described. For assessment of the mid-term outcomes, activities of daily living (ADL) at 24 months after intervention were evaluated with the modified Rankin Scale (mRS). The operative morbidity rate was 6.7% in the open surgery group and 6.5% in the endovascular surgery group, and they did not differ significantly. The frequency of patients with mRS 0-2 at 24 months after intervention was 85.7% in the open surgery group and 82.8% in the endovascular surgery group, and they did not differ significantly. The adverse event rate of patients with middle cerebral artery aneurysms treated endovascularly was high (80%). The outcomes of individuals aged ≥ 75 years who underwent repair of UA were generally favorable in either treatment group, with more than 80% living an independent life at 24 months after intervention. © 2013 Japan Geriatrics Society.

  16. Endovascular Neurosurgery: Personal Experience and Future Perspectives.

    Science.gov (United States)

    Raymond, Jean

    2016-09-01

    From Luessenhop's early clinical experience until the present day, experimental methods have been introduced to make progress in endovascular neurosurgery. A personal historical narrative, spanning the 1980s to 2010s, with a review of past opportunities, current problems, and future perspectives. Although the technology has significantly improved, our clinical culture remains a barrier to methodologically sound and safe innovative care and progress. We must learn how to safely practice endovascular neurosurgery in the presence of uncertainty and verify patient outcomes in real time. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Endovascular embolization of mirror brain aneurysms

    International Nuclear Information System (INIS)

    Sirakov, S.; Penkov, M.; Sirakov, A.; Todorov, Y.; Ninov, K.; Minkin, K.; Bachvarov, Ch.

    2016-01-01

    Aneurysms of the vertebral artery are rare, constituting 0.5 to 3% of all intracranial aneurysms and less than 20% of those of the posterior brain circulation. Bilateral - mirror aneurysms on vertebral artery are extremely rare and unusual lesions, but are often seen and treated in the setting of acute subarachnoid hemorrhage or stroke in the posterior circulation. The treatment of such aneurysms of the vertebral artery with their specific anatomical location is great challenge to traditional neurosurgery. We present our experience with endovascular approach with this pathology. Key words: Mirror Brain Aneurysm. Endovascular Embolization

  18. Blunt traumatic aortic injury: initial experience with endovascular repair.

    Science.gov (United States)

    Azizzadeh, Ali; Keyhani, Kourosh; Miller, Charles C; Coogan, Sheila M; Safi, Hazim J; Estrera, Anthony L

    2009-06-01

    Endovascular treatment of traumatic aortic injury (TAI) is an alternative to open repair (OR) in patients with blunt trauma. We report our initial experience after integration of endovascular repair using thoracic devices. A retrospective review of a prospectively collected institutional trauma registry was performed. Between September 2005 and November 2008, 71 patients with TAI presented to our institution. Based on imaging, TAIs were classified into grade 1-4 in severity. These included: grade 1, intimal tear; grade 2, intramural hematoma; grade 3, aortic pseudoaneurysm; and grade 4, free rupture. Initial management included resuscitation, blood pressure control, and treatment of associated injuries. After stabilization, all patients were considered for thoracic endovascular aortic repair (TEVAR) using a thoracic device. If contraindicated, candidates underwent OR. Outcome measures were mortality, stroke, paraplegia, intensive care unit (ICU), and hospital stay. The mean age was 39.8 years, with 50 males. The mean injury severity score (ISS) was 42.6. Nineteen (27%) patients with a mean ISS of 60 died shortly after arrival prior to any vascular intervention. Ten (14%) patients with grade 1 injuries were managed medically. The remaining 42 (59%) patients with grade 2 and 3 injuries underwent repair. Median interval between admission and repair was 4.3 days (range, 0-109 days). Fifteen (21%) patients with a mean ISS of 34.4 underwent OR with no mortality, stroke, or paraplegia. Twenty-seven (38%) patients with a mean ISS of 36.7 underwent TEVAR with no mortality or paraplegia. One TEVAR patient suffered a perioperative stroke. Twenty-two patients had a TAG (W.L. Gore & Associates, Flagstaff, Ariz) device. Four patients had a Talent Thoracic (Medtronic Vascular, Santa Rosa, Calif), and 1 patient had an Excluder (W.L. Gore) device. The left subclavian artery was covered in 13 (48%) patients. Patients who underwent TEVAR were older than those who had OR (47.8 vs 31

  19. Total Endovascular Treatment of Acute Non-A-non-B Dissection Complicated by Visceral Malperfusion without Primary Entry Tear Coverage.

    Science.gov (United States)

    Soler, Raphael J; Bartoli, Michel A; Simonet, Gaetan; Amabile, Philippe; Sarlon-Bartoli, Gabrielle; Magnan, Pierre-Edouard

    2017-11-01

    Management of visceral ischemia due to non-A, non-B dissection is extremely challenging due to the position of the primary entry tear at the level of the brachiocephalic vessels. We report on a patient who was admitted for a complicated non-A, non-B-type dissection with visceral and leg ischemia. A covered stent graft was implanted below the primary entry tear to redirect the flow in the true lumen, associated with stents implantation in the visceral arteries, to treat the dissection's static component. The patient did well, without need for bowel resection visceral or late stent restenosis. Stent-graft implantation below the primary entry tear in cases of visceral ischemia due to non-A, non-B dissection seems feasible. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Preoperative Evaluation and Endovascular Procedure of Intraoperative Aneurysm Rupture During Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Zha, Bin-Shan, E-mail: binszha2013@163.com; Zhu, Hua-Gang, E-mail: huagzhu@yeah.net; Ye, Yu-Sheng, E-mail: yeyusheng@aliyun.com; Li, Yong-Sheng, E-mail: 872868848@qq.com; Zhang, Zhi-Gong, E-mail: zzgedward@sina.com; Xie, Wen-Tao, E-mail: 345344347@qq.com [The First Affiliated Hospital of Anhui Medical University, Department of Vascular Surgery (China)

    2017-03-15

    Thoracic aortic aneurysms are now routinely repaired with endovascular repair if anatomically feasible because of advantages in safety and recovery. However, intraoperative aneurysm rupture is a severe complication which may have an adverse effect on the outcome of treatment. Comprehensive preoperative assessment and considerate treatment are keys to success of endovascular aneurysm repair, especially during unexpected circumstances. Few cases have reported on intraoperative aortic rupture, which were successfully managed by endovascular treatment. Here, we present a rare case of an intraoperative aneurysm rupture during endovascular repair of thoracic aortic aneurysm with narrow neck and angulated aorta arch (coarctation-associated aneurysm), which was successfully treated using double access route approach and iliac limbs of infrarenal devices.Level of EvidenceLevel 5.

  1. NUTRITION SUPPORT COMPLICATIONS IN PATIENT WHO UNDERWENT CARDIAC SURGERY

    OpenAIRE

    Krdžalić, Alisa; Kovčić, Jasmina; Krdžalić, Goran; Jahić, Elmir

    2016-01-01

    Background: The nutrition support complications after cardiac surgery should be detected and treated on time. Aim: To show the incidence and type of nutritional support complication in patients after cardiac surgery. Methods: The prospective study included 415 patients who underwent cardiac surgery between 2010 and 2013 in Clinic for Cardiovascular Disease of University Clinical Center Tuzla. Complications of the delivery system for nutrition support (NS) and nutrition itself were analy...

  2. Bronchoscopic guidance of endovascular stenting limits airway compression.

    Science.gov (United States)

    Ebrahim, Mohammad; Hagood, James; Moore, John; El-Said, Howaida

    2015-04-01

    Bronchial compression as a result of pulmonary artery and aortic arch stenting may cause significant respiratory distress. We set out to limit airway narrowing by endovascular stenting, by using simultaneous flexible bronchoscopy and graduated balloon stent dilatation, or balloon angioplasty to determine maximum safe stent diameter. Between August 2010 and August 2013, patients with suspected airway compression by adjacent vascular structures, underwent CT or a 3D rotational angiogram to evaluate the relationship between the airway and the blood vessels. If these studies showed close proximity of the stenosed vessel and the airway, simultaneous bronchoscopy and graduated stent re-dilation or graduated balloon angioplasty were performed. Five simultaneous bronchoscopy and interventional catheterization procedures were performed in four patients. Median age/weight was 33 (range 9-49) months and 14 (range 7.6-24) kg, respectively. Three had hypoplastic left heart syndrome, and one had coarctation of the aorta (CoA). All had confirmed or suspected left main stem bronchial compression. In three procedures, serial balloon dilatation of a previously placed stent in the CoA was performed and bronchoscopy was used to determine the safest largest diameter. In the other two procedures, balloon testing with simultaneous bronchoscopy was performed to determine the stent size that would limit compression of the adjacent airway. In all cases, simultaneous bronchoscopy allowed selection of an ideal caliber of the stent that optimized vessel diameter while minimizing compression of the adjacent airway. In cases at risk for airway compromise, flexible bronchoscopy is a useful tool to guide endovascular stenting. Maximum safe stent diameter can be determined without risking catastrophic airway compression. © 2014 Wiley Periodicals, Inc.

  3. REHEARSAL Using Patient-Specific Simulation to Improve Endovascular Efficiency.

    Science.gov (United States)

    Wooster, Mathew; Doyle, Adam; Hislop, Sean; Glocker, Roan; Armstrong, Paul; Singh, Michael; Illig, Karl A

    2018-04-01

    To determine whether rehearsal using patient-specific information loaded onto an endovascular simulator prior to carotid stenting improves procedural efficiency and outcomes. Patients scheduled for carotid artery stenting who had adequate preoperative computed tomography (CT) imaging were considered for enrollment. After obtaining informed consent, patients were randomized to control versus rehearsal groups. Those in the rehearsal group had their CT scans loaded into an endovascular simulator (Angio Mentor) followed by case rehearsal by the attending on the simulator within 24 hours prior to the procedure; control patients underwent routine carotid stenting without rehearsal. Contrast usage, fluoroscopy time, and timing of procedural steps were recorded by a blinded observer during the actual case to determine benefit. Fifteen patients were enrolled, with 6 patients randomized to the rehearsal group and 9 to the control. All measures showed improvement in the rehearsal group: Mean contrast volume (59.2 vs 76.9 mL), fluoroscopy time (11.4 vs 19.4 minutes), overall operative time (31.9 vs 42.5 minutes), time to common carotid sheath placement (17.0 vs 23.3 minutes), and total carotid sheath dwell time (14.9 vs 19.2 minutes) were all lower (more favorable) in the rehearsal group. The study was terminated early due to the lack of simulator access, and all P values were thus greater than .05 due to the lack of power. No strokes or other adverse events occurred in either group. Case-specific simulator rehearsal using patient-specific imaging prior to carotid stenting is associated with numerically less contrast usage, operative time, and radiation exposure, although this study was underpowered.

  4. Endovascular Therapeutic Approaches for Acute Superior Mesenteric Artery Occlusion

    International Nuclear Information System (INIS)

    Acosta, S.; Sonesson, B.; Resch, T.

    2009-01-01

    The purpose of this study was to characterize the outcome of attempted endovascular intervention in patients with acute embolic or thrombotic superior mesenteric artery (SMA) occlusion. The records of 21 patients during a 3-year period between 2005 and 2008 were retrieved from the in-hospital registry. The first group included 10 patients (6 women and 4 men; median age 78 years) with acute embolic occlusion of the SMA. The median duration of symptoms from symptom onset to angiography was 30 hours (range 6 to 120). Synchronous emboli (n = 12) occurred in 6 patients. Embolus aspiration was performed in 9 patients, and 7 of these had satisfactory results. Complementary local thrombolysis was successful in 2 of 3 patients. Residual emboli were present at completion angiography in all 7 patients who underwent successful aspiration embolectomy, and bowel resection was necessary in only 1 of these patients. One serious complication occurred because of a long SMA dissection. The in-hospital survival rate was 90% (9 of 10 patients). The second group included 11 patients (10 women and 1 man; median age 68 years) with atherosclerotic acute SMA occlusions. The median time of symptom duration before intervention was 97 hours (range 17 to 384). The brachial, femoral, and SMA routes were used in 6, 7, and 5 patients, respectively. SMA stenting was performed through an antegrade (n = 7) or retrograde (n = 3) approach. Bowel resection was necessary in 4 patients. No major complications occurred. The in-hospital survival rate was 82% (9 of 11 patients). Endovascular therapy of acute SMA occlusion provides a good alternative to open surgery.

  5. Clinical outcomes of endovascularly managed iatrogenic renal hemorrhages

    International Nuclear Information System (INIS)

    Chiramel, George Koshy; Keshava, Shyamkumar Nidugala; Moses, Vinu; Kekre, Nitin; Tamilarasi, V; Devasia, Anthony

    2015-01-01

    To evaluate the effectiveness of endovascular management in iatrogenic renal injuries with regard to clinical status on follow-up and requirements for repeat angiography and embolization. This retrospective study included patients who were referred for endovascular management of significant hemorrhage following an iatrogenic injury. Data was recorded from the Picture Archiving and Communication system (PACS) and electronic medical records. The site and type of iatrogenic injury, imaging findings, treatment, angiography findings, embolization performed, clinical status on follow-up, and requirement for repeat embolization were recorded. The outcomes were clinical resolution, nephrectomy, or death. Clinical findings were recorded on follow-up visits to the clinic. Statistical analysis was performed using descriptive statistics. Seventy patients were included in this study between January 2000 and June 2012. A bleeding lesion (a pseudoaneurysm or arteriovenous fistula) was detected during the first angiogram in 55 patients (78.6%) and was selectively embolized. Fifteen required a second angiography as there was no clinical improvement and five required a third angiography. Overall, 66 patients (94.3%) showed complete resolution and 4 patients (5.7%) died. Three patients (4.3%) underwent nephrectomy for clinical stabilization even after embolization. There were no major complications. The two minor complications resolved spontaneously. Angiography and embolization is the treatment of choice in iatrogenic renal hemorrhage. Upto 20% of initial angiograms may not reveal the bleed and repeat angiography is required to identify a recurrent or unidentified bleed. The presence of multiple punctate bleeders on angiography suggests an enlarging subcapsular hematoma and requires preoperative embolization and nephrectomy

  6. Endovascular treatment of symptomatic intracranial atherosclerotic disease

    Directory of Open Access Journals (Sweden)

    Syed I Hussain

    2011-02-01

    Full Text Available Abstract: Symptomatic intracranial atherosclerotic disease (ICAD is responsible for approximately 10% of all ischemic strokes in the United States. The risk of recurrent stroke may be as high as 35% in patient with critical stenosis greater than 70% in diameter narrowing. Recent advances in medical and endovascular therapy have placed ICAD at the forefront of clinical stroke research to optimize the best medical and endovascular approach to treat this important underlying stroke etiology. Analysis of symptomatic ICAD studies lead to the question that whether angioplasty and or stenting is a safe, suitable and efficacious therapeutic strategy in patients with critical stenoses that are deemed refractory to medical management. Most of the currently available data in support of angioplasty and or stenting in high risk patients with severe symptomatic ICAD is in the form of case series and randomized trial results of endovascular therapy versus medical treatment are awaited. This is a comprehensive review of the state of the art in the endovascular approach with angioplasty and or stenting of symptomatic intracranial atherosclerotic disease.

  7. Endovascular treatment of ruptured distal posterior inferior ...

    African Journals Online (AJOL)

    Results: All patients were treated by endovascular treatment, seven cases got endosaccular coiling and four cases got parent artery occlusion at the same time. All the patients were followed up one to four years. Recurrences occurred in 1 patient two years post-treatment, and were successfully retreated by endosaccular ...

  8. Aorfix™ device for abdominal aortic aneurysm with challenging anatomy.

    Science.gov (United States)

    Sbarzaglia, P; Grattoni, C; Oshoala, K; Castriota, F; D'Alessandro, G; Cremonesi, A

    2014-02-01

    Anatomical characteristics of abdominal aortic aneurysms (AAA) are the most critical factors for successful endovascular aortic repair (EVAR). Of these, severe proximal aortic neck angulation and iliac axis tortuosity increase the complexity of EVAR. Neck angulation seems to have a pivotal potential for fixation failure, a situation that may lead to complications, including endoleak and late rupture. Bench-test studies identified that the relative stiffness of a stent-graft was responsible for its inability to conform to neck angulation, therefore creating leaks through gaps between the stent graft and the neck. Aorfix™ stent graft (Lombard Medical, Didcot, UK) is a flexible stent-graft designed and manufactured with the purpose of overcoming the issue of stent-graft stiffness. Many studies have shown good results in term of procedural success and mid-term type-I endoleak. PYTHAGORAS trial evaluated mainly patients with highly angulated infrarenal neck and showed that high performance of Aorfix™ stent graft did not present any significant difference between neck >60° and <60°. In the series of 27 patients treated at our Institution we had a primary technical success of 96.3% and an assisted primary technical success of 100%. In this review we will analyze the available data in literature regarding Aorfix™ stent graft and will discuss the outcome of the patients treated with Aorfix™ stent graft at our centre.

  9. Endovascular repair of an innominate artery pseudoaneurysm using the Valiant Mona LSA branched graft device

    Directory of Open Access Journals (Sweden)

    Josh A. Sibille, MD

    2017-03-01

    Full Text Available A 60-year-old woman involved in a motor vehicle collision presented with a traumatic pseudoaneurysm of the innominate artery origin in addition to multiple concomitant injuries. She was classified as a high-risk candidate for open repair. An experimental thoracic branched graft device was used for coverage of the injury with the addition of a right carotid-to-left carotid-to-left subclavian artery bypass. Follow-up imaging showed resolution of the pseudoaneurysm and patency of her bypass grafts. This is the first described use of the Mona LSA Branch Thoracic Stent Graft System (Medtronic, Minneapolis, Minn in the innominate artery.

  10. Endovascular Management of Deep venous Thrombosis of Lower Extremity in Patients with Malignant Disease

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Su Jin; Kim, Jae Kyu; Jang, Nam Kyu; Han, Seung Min; Kang, Heoung Keun; Choi, Soo Jin Nah [Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2009-07-15

    To evaluate the efficacy of endovascular management of lower extremity deep vein thrombosis (DVT) in patients with malignant disease. Between January 2002 and January 2008, six consecutive patients (5 male and 1 female, mean age-65 years) with lower extremity DVT and malignant disease underwent endovascular management. The duration of symptoms lasted 4-120 days (mean-31 days; 20 days or less in four patients and more than 20 days in two). A catheter-directed thrombolysis was performed via the ipsilateral popliteal vein or common femoral vein, used alone or combined with a percutaneous mechanical thrombectomy. Angioplasty or stent placement was performed in residual stenosis or occlusion of the vein. The follow-up period lasted 1-14 months (mean 7.6 months) and was performed via a color Doppler ultrasonography or computed tomographic venography. Technical success and relief from symptoms was achieved within two days was achieved in five patients. Minor hemorrhagic complications occurred in two cases: hematuria and a hematoma at the puncture site. Upon follow-up, a recurrent DVT occurred in three patients as well as a patent venous flow in two. One patient died within 1 month due to a metastatic mediastinal lymphadenopathy. Endovascular management of the lower extremity DVT is effective for quickly eliminating a thrombus, relieving symptoms, and decreasing hemorrhagic complications in patients with malignant disease.

  11. Preliminary clinical study on endovascular treatment of posterior inferior cerebellar artery aneurysms

    International Nuclear Information System (INIS)

    Zhao Bing; Zhong Ming; Tan Xianxi; Zheng Kuang; Zhang Mingsheng; Yin Jian; He Wengen

    2009-01-01

    Objective: To study the methods and results of endovascular treatment of posterior inferior cerebellar artery (PICA) aneurysms. Methods: Twenty-one patients with PICA aneurysms were treated with endovascular treatment. The locations of aneurysm on PICA were evaluated through the DSA. Eight patients received single coil embolization, 5 received liquid Glue embolization, 2 received coil embolization combined with liquid Glue, 2 received coil embolization assisted with stents, and 4 underwent occlusion of the parent PICA. Outcome was evaluated with the Glasgow outcome scale (GOS). Results: There were complete (100%) occlusion in 5 patients, near complete (> 90%) occlusion in 2, and incomplete (85%) occlusion in 1 in single coil embolization. Seven patients with Glue embolization (n=5) or combination with coils (n=2) exhibited complete (100%) occlusion. There were near complete (>90%) occlusion in 2 cases with coil assisted with stents. Complete occlusion of the parent PICA was achieved in 3 patients, and near complete occlusion of PICA in one case. One patient suffered from new neurological deficits, and one patient treated with coils and stents died. None of the patients suffered from re-bleeding. There patients received follow-up during a mean period of (22 ± 8) months. Overall long-term outcome was good (GOS score 4 or 5) in 17 patients, poor (GOS score 2 or 3) in 3, and fatal (GOS score 1 ) in one case. Conclusions: According to the location of aneurysms on PICA, aneurysms can be effectively and safely treated with endovascular embolization. (authors)

  12. Surgical Clipping versus Endovascular Intervention for the Treatment of Subarachnoid Hemorrhage Patients in New York State.

    Directory of Open Access Journals (Sweden)

    Kimon Bekelis

    Full Text Available Randomized trials have demonstrated a survival benefit for endovascular treatment of ruptured cerebral aneurysms. We investigated the association of surgical clipping and endovascular coiling with outcomes in subarachnoid hemorrhage (SAH patients in a real-world regional cohort.We performed a cohort study involving patients with ruptured cerebral aneurysms, who underwent surgical clipping, or endovascular coiling from 2009-2013 and were registered in the Statewide Planning and Research Cooperative System (SPARCS database. An instrumental variable analysis was used to investigate the association of treatment technique with outcomes.Of the 4,098 patients undergoing treatment, 2,585 (63.1% underwent coiling, and 1,513 (36.9% underwent clipping. Using an instrumental variable analysis, we did not identify a difference in inpatient mortality [marginal effect (ME, -0.56; 95% CI, -1.03 to 0.02], length of stay (LOS (ME, 1.72; 95% CI, -3.39 to 6.84, or the rate of 30-day readmissions (ME, -0.30; 95% CI, -0.82 to 0.22 between the two treatment techniques for patients with SAH. Clipping was associated with a higher rate of discharge to rehabilitation (ME, 0.63; 95% CI, 0.24 to 1.01. In sensitivity analysis, mixed effect regression, and propensity score adjusted regression models demonstrated identical results.Using a comprehensive all-payer cohort of patients in New York State presenting with aneurysmal SAH we did not identify an association of treatment method with mortality, LOS or 30-day readmission. Clipping was associated with a higher rate of discharge to rehabilitation.

  13. Thoracic Endovascular Aortic Repair in a Patient with Mobile Aortic Thrombosis

    Directory of Open Access Journals (Sweden)

    Graham M. Lohrmann

    2014-01-01

    Full Text Available A 58-year-old female presented with acute arterial insufficiency to her left leg. Following cardiovascular evaluation using multimodality imaging, it was discovered that she had mobile thoracic thrombi overlying a normal descending thoracic aorta which had also caused a splenic infarction. This patient was treated with unfractionated heparin for three days and underwent subsequent thoracic endovascular aortic repair (TEVAR uneventfully with no subsequent complications at one-year followup. This case highlights the diagnostic and therapeutic challenges in treating patients with this uncommon challenging clinical scenario.

  14. An unique case of thoracic endovascular aortic repair (TEVAR) graft infection with Streptococcus viridans.

    Science.gov (United States)

    Zubaidah, N H; Azim, M I M; Osama, M H; Harunarashid, H; Das, S

    2012-01-01

    The incidence of infection following TEVAR is low. To the best of our knowledge, this is the first case report of post thoracic endovascular aortic repair (TEVAR) with Streptococcus viridans graft infection. A 54-year-old male underwent TEVAR for dissecting thoracic aneurysm with spinal ischaemia. He had an eventful recovery with prolonged period of stay in intensive care unit. Three months later, he presented with persistent chest discomfort and fever. Computed tomography (CT) of the thorax revealed evidence of graft infection and the blood culture grew Streptococcus viridans. The rarity of TEVAR graft infection due to Streptococcus viridans and its management are being discussed.

  15. Endovascular Management of Acute Embolic Occlusion of the Superior Mesenteric Artery: A 12-Year Single-Centre Experience

    International Nuclear Information System (INIS)

    Raupach, J.; Lojik, M.; Chovanec, V.; Renc, O.; Strýček, M.; Dvořák, P.; Hoffmann, P.; Guňka, I.; Ferko, A.; Ryška, P.; Omran, N.; Krajina, A.; Čabelková, P.; Čermáková, E.; Malý, R.

    2016-01-01

    PurposeRetrospective evaluation of 12-year experience with endovascular management of acute mesenteric ischemia (AMI) due to embolic occlusion of the superior mesenteric artery (SMA).Materials and methodsFrom 2003 to 2014, we analysed the in-hospital mortality of 37 patients with acute mesenteric embolism who underwent primary endovascular therapy with subsequent on-demand laparotomy. Transcatheter embolus aspiration was used in all 37 patients (19 women, 18 men, median age 76 years) with embolic occlusion of the SMA. Adjunctive local thrombolysis (n = 2) and stenting (n = 2) were also utilised.ResultsWe achieved complete recanalization of the SMA stem in 91.9 %. One patient was successfully treated by surgical embolectomy due to a failed endovascular approach. Subsequent exploratory laparotomy was performed in 73.0 % (n = 27), and necrotic bowel resection in 40.5 %. The total in-hospital mortality was 27.0 %.ConclusionPrimary endovascular therapy for acute embolic SMA occlusion with on-demand laparotomy is a recommended algorithm used in our centre to treat SMA occlusion. This combined approach for the treatment of AMI is associated with in-hospital mortality rate of 27.0 %

  16. Endovascular Management of Acute Embolic Occlusion of the Superior Mesenteric Artery: A 12-Year Single-Centre Experience

    Energy Technology Data Exchange (ETDEWEB)

    Raupach, J., E-mail: janraupach@seznam.cz; Lojik, M., E-mail: miroslav.lojik@fnhk.cz; Chovanec, V., E-mail: chovanec.v@seznam.cz; Renc, O., E-mail: ondrejrenc@seznam.cz [Faculty of Medicine at Charles University and University Hospital, Department of Radiology (Czech Republic); Strýček, M., E-mail: m.strycek@gmail.com [Faculty of Medicine at Charles University (Czech Republic); Dvořák, P., E-mail: petr.dvorak@fnhk.cz; Hoffmann, P., E-mail: hoffmpet@fnhk.cz [Faculty of Medicine at Charles University and University Hospital, Department of Radiology (Czech Republic); Guňka, I., E-mail: gunka@email.cz; Ferko, A., E-mail: a.ferko@seznam.cz [Faculty of Medicine at Charles University and University Hospital, Department of Surgery (Czech Republic); Ryška, P., E-mail: ryska@fnhk.cz [Faculty of Medicine at Charles University and University Hospital, Department of Radiology (Czech Republic); Omran, N., E-mail: nidal81@gmail.com [Faculty of Medicine at Charles University and University Hospital, Department of Cardiac Surgery (Czech Republic); Krajina, A., E-mail: krajina@fnhk.cz; Čabelková, P., E-mail: pavla.cabelkova@fnhk.cz [Faculty of Medicine at Charles University and University Hospital, Department of Radiology (Czech Republic); Čermáková, E., E-mail: cermakovae@lfhk.cuni.cz [Faculty of Medicine at Charles University, Computer Technology Center (Czech Republic); Malý, R., E-mail: malyr@volny.cz [Faculty of Medicine at Charles University and University Hospital, Department of Medicine (Czech Republic)

    2016-02-15

    PurposeRetrospective evaluation of 12-year experience with endovascular management of acute mesenteric ischemia (AMI) due to embolic occlusion of the superior mesenteric artery (SMA).Materials and methodsFrom 2003 to 2014, we analysed the in-hospital mortality of 37 patients with acute mesenteric embolism who underwent primary endovascular therapy with subsequent on-demand laparotomy. Transcatheter embolus aspiration was used in all 37 patients (19 women, 18 men, median age 76 years) with embolic occlusion of the SMA. Adjunctive local thrombolysis (n = 2) and stenting (n = 2) were also utilised.ResultsWe achieved complete recanalization of the SMA stem in 91.9 %. One patient was successfully treated by surgical embolectomy due to a failed endovascular approach. Subsequent exploratory laparotomy was performed in 73.0 % (n = 27), and necrotic bowel resection in 40.5 %. The total in-hospital mortality was 27.0 %.ConclusionPrimary endovascular therapy for acute embolic SMA occlusion with on-demand laparotomy is a recommended algorithm used in our centre to treat SMA occlusion. This combined approach for the treatment of AMI is associated with in-hospital mortality rate of 27.0 %.

  17. Pigmented Villonodular Synovitis in a Patient who Underwent Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Nevzat Dabak

    2014-09-01

    Full Text Available Pigmented villonodular synovitis (PVNS is a rare, benign, but a locally aggressive tumor. It is characterized by the proliferation of synovial membrane, but it can also be seen in tendon sheaths and bursae. Clinical presentation of solitary lesions include compression and locking of the joint suggesting loose bodies in the joint and a subsequent findings of an effusion, whereas diffuse lesions manifest with pain and chronic swelling. In this article, we presented a curious case of PVNS in a female patient who have been followed up due to an acetabular cystic lesion. She underwent total hip arthroplasty for severe osteoarthritis of the hip joint and associated pain. The diagnosis of PVNS was established intraoperatively. (The Me­di­cal Bul­le­tin of Ha­se­ki 2014; 52: 235-7

  18. ALGORITHM FOR MANAGEMENT OF HYPERTENSIVE PATIENTS UNDERWENT UROLOGY INTERVENTIONS

    Directory of Open Access Journals (Sweden)

    S. S. Davydova

    2015-09-01

    Full Text Available Aim. To study the efficacy of cardiovascular non-invasive complex assessment and pre-operative preparation in hypertensive patients needed in surgical treatment of urology dis- eases.Material and methods. Males (n=883, aged 40 to 80 years were included into the study. The main group consisted of patients that underwent laparotomic nephrectomy (LTN group; n=96 and patients who underwent laparoscopic nephrectomy (LSN group; n=53. Dynamics of ambulatory blood pressure monitoring (ABPM data was analyzed in these groups in the immediate postoperative period. The efficacy of a package of non-invasive methods for cardiovascular system assessment was studied. ABPM was performed after nephrectomy (2-nd and 10-th days after surgery in patients with complaints of vertigo episodes or intense general weakness to correct treatment.Results. In LTN group hypotension episodes or blood pressure (BP elevations were observed in 20 (20.8% and 22 (22.9% patients, respectively, on the 2-nd day after the operation. These complications required antihypertensive treatment correction. Patients with hypotension episodes were significantly older than patients with BP elevation and had significantly lower levels of 24-hour systolic BP, night diastolic BP and minimal night systolic BP. Re-adjustment of antihypertensive treatment on the 10-th postoperative day was required to 2 (10% patients with hypotension episodes and to 1 (4.5% patient with BP elevation. Correction of antihypertensive therapy was required to all patients in LSN group on the day 2, and to 32 (60.4% patients on the 10-th day after the operation. Reduction in the incidence of complications (from 1.2% in 2009 to 0.3% in 2011, p<0.001 was observed during the application of cardiovascular non-invasive complex assessment and preoperative preparation in hypertensive patients.Conclusion. The elaborated management algorithm for patients with concomitant hypertension is recommended to reduce the cardiovascular

  19. ALGORITHM FOR MANAGEMENT OF HYPERTENSIVE PATIENTS UNDERWENT UROLOGY INTERVENTIONS

    Directory of Open Access Journals (Sweden)

    S. S. Davydova

    2013-01-01

    Full Text Available Aim. To study the efficacy of cardiovascular non-invasive complex assessment and pre-operative preparation in hypertensive patients needed in surgical treatment of urology dis- eases.Material and methods. Males (n=883, aged 40 to 80 years were included into the study. The main group consisted of patients that underwent laparotomic nephrectomy (LTN group; n=96 and patients who underwent laparoscopic nephrectomy (LSN group; n=53. Dynamics of ambulatory blood pressure monitoring (ABPM data was analyzed in these groups in the immediate postoperative period. The efficacy of a package of non-invasive methods for cardiovascular system assessment was studied. ABPM was performed after nephrectomy (2-nd and 10-th days after surgery in patients with complaints of vertigo episodes or intense general weakness to correct treatment.Results. In LTN group hypotension episodes or blood pressure (BP elevations were observed in 20 (20.8% and 22 (22.9% patients, respectively, on the 2-nd day after the operation. These complications required antihypertensive treatment correction. Patients with hypotension episodes were significantly older than patients with BP elevation and had significantly lower levels of 24-hour systolic BP, night diastolic BP and minimal night systolic BP. Re-adjustment of antihypertensive treatment on the 10-th postoperative day was required to 2 (10% patients with hypotension episodes and to 1 (4.5% patient with BP elevation. Correction of antihypertensive therapy was required to all patients in LSN group on the day 2, and to 32 (60.4% patients on the 10-th day after the operation. Reduction in the incidence of complications (from 1.2% in 2009 to 0.3% in 2011, p<0.001 was observed during the application of cardiovascular non-invasive complex assessment and preoperative preparation in hypertensive patients.Conclusion. The elaborated management algorithm for patients with concomitant hypertension is recommended to reduce the cardiovascular

  20. Analysis of the MELD Score Impact in the Outcome of Endovascular Portal Vein Reconstruction.

    Science.gov (United States)

    Torres-Machorro, Adriana; Guerrero-Hernandez, Manuel; Anaya-Ayala, Javier E; Torre, Aldo; Laparra-Escareno, Hugo; Cuen-Ojeda, Cesar; Garcia-Alva, Ramón; Hinojosa, Carlos A

    Endovascular therapy represents a less invasive alternative to open surgery for reconstruction of the portal vein (PV) and the spleno-mesenteric venous confluence to treat Portal hypertension. The objective of this study is to determine if the Model for End-Stage Liver Disease (MELD) score is a useful method to evaluate the risk of morbidity and mortality during endovascular approaches. Patients that underwent endovascular reconstruction of the PV or spleno-mesenteric confluence were identified retrospectively. Data were collected from November 2011 to August 2016. The MELD score was calculated using international normalized ratio, serum billirubin and creatinine. Patients were grouped into moderate (≤ 15) and high (> 15) MELD. Associations of the MELD score on the postprocedural morbidity, mortality and vessels patency were assessed by two-sided Fisher's exact test. Seventeen patients were identified; MELD score distribution was: ≤ 15 in 10 patients (59%) and > 15 in 7 (41%). Even distribution of severe PV thrombosis was treated in both groups, performing predominately jugular access in the high MELD score group (OR 0.10; 95%; CI 0.014-0.89; p = 0.052) in contrast to a percutaneous transhepatic access in the moderate MELD score group. Analysis comparing moderate and high MELD scores was not able to demonstrate differences in mortality, morbidity or patency rates. MELD score did not prove to be a useful method to evaluate risk of morbidity and mortality; however a high score should not contraindicate endovascular approaches. In our experience a high technical success, good patency rates and low complication rates were observed.

  1. Hemorrhagic risk of emergent endovascular treatment plus stenting in patients with acute ischemic stroke.

    Science.gov (United States)

    Dorado, Laura; Castaño, Carlos; Millán, Mònica; Aleu, Aitziber; de la Ossa, Natàlia Pérez; Gomis, Meritxell; López-Cancio, Elena; Vivas, Elio; Rodriguez-Campello, Ana; Castellanos, Mar; Dávalos, Antoni

    2013-11-01

    Several endovascular revascularization strategies have been described for the treatment of acute ischemic stroke (AIS). One of them is stenting when a very narrow stenosis with high reocclusion risk remains after recanalization. This study describes the risk of symptomatic intracerebral hemorrhage (SICH) after emergent stenting in patients with AIS treated with endovascular therapies. Consecutive patients who underwent endovascular treatment over a 37-month period were retrospectively analyzed. Patients were classified in 2 groups: (1) patients in whom a stent was deployed; and (2) patients without stenting. Double antiplatelet treatment with aspirin and clopidogrel was administered at the time of stenting. SICH was defined as any hemorrhagic transformation with National Institutes of Health Stroke Scale (NIHSS) score worsening 4 points or more (European-Australasian Acute Stroke Study II criteria). A total of 143 patients were included (mean age: 66.1±11.7 years, median NIHSS score: 18). Acute phase stenting was performed in 24 subjects (16.8%): 4 intracranial (3 in basilar artery, 1 in middle cerebral artery) and 20 extracranial (internal carotid artery). SICH occurred in 11 patients, 5 of 24 (20.8%) in patients with stenting and in 3 of 119 (2.5%) without (P=.008). No differences were found with respect to baseline NIHSS score or intravenous tissue plasminogen activator administration. Acute phase stenting emerged as an independent predictor of SICH after adjustment for potential confounders and procedure duration: odds ratio 7.3 (confidence interval 1.4-36.8, P=.016). Our findings suggest that emergent stenting in endovascular treatment of AIS is associated with SICH. Copyright © 2013 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  2. Manejo endovascular de la aorta torácica Endovascular treatment of thoracic aorta

    Directory of Open Access Journals (Sweden)

    Juan G Barrera

    2006-10-01

    Full Text Available En comparación con el tratamiento convencional, la terapia endovascular en aneurisma de aorta torácica, presenta los mejores resultados, por lo que se convierte en el tratamiento de elección para la patología de aorta torácica descendente endovascular, por su baja morbimortalidad perioperatoria. El tratamiento quirúrgico por vía retroperitoneal y/o endovascular para aneurisma de aorta abdominal infrarrenal, resulta ser especialmente seguro en pacientes octogenarios o con alta morbilidad. Esta cohorte institucional presenta resultados perioperatorios y en el seguimiento, similares a los reportados en la literatura mundial.Compared with the conventional treatment, endovascular therapy in thoracic aortic aneurysm shows the best results, being the election treatment for the pathology of the descending thoracic aorta, due to its low peri-operative morbid-mortality. Surgical treatment by retro-peritoneal route and/or endovascular for infra-renal abdominal aortic aneurysm is especially safe in octogenarian patients or in those with a high mortality rate. This institutional cohort show peri-operative and follow-up results similar to those reported in the world literature.

  3. Endovascular treatment of spine and spinal cord lesions

    International Nuclear Information System (INIS)

    Berenstein, A.

    1992-01-01

    Completing this comprehensive series on endovascular interventional angiography, Volume 5 focuses on the vascular abnormalities of the spine and spinal cord. It is based on the detailed functional vascular anatomy described in Volume 3 and the principles and function of endovascular treatment described in Volumes 1-4. As in the companion volumes, the unique approach gives view of the disease itself, its anatomical features and its clinical presentation. The technical aspects of the interventional or endovascular neuroradiology are built upon the solid analysis of the disease and its angioarchitecture. The recent developments in endovascular procedures, such as aneurysm treatment, angioplasty, and vascular recanalizations, are reviewed. (orig.). 118 figs. in 442 separate illustrations

  4. Hybrid thoracic endovascular aortic repair: pushing the envelope.

    Science.gov (United States)

    Younes, Houssam K; Davies, Mark G; Bismuth, Jean; Naoum, Joseph J; Peden, Eric K; Reardon, Michael J; Lumsden, Alan B

    2010-01-01

    Thoracic endovascular aortic repair (TEVAR) can be limited by inadequate proximal and distal landing zones. Debranching or hybrid TEVAR has emerged as an important modality to expand landing zones and facilitate TEVAR. We report a single-center experience with hybrid TEVAR. We retrospectively reviewed all patients with thoracic aortic disease who received a TEVAR between February 2005 and October 2008. Forty-two patients underwent a hybrid procedure (mean age 68 +/- 13 years; 55% men). All patients were denied open surgery due to preoperative comorbidities or low physiologic reserve; 62% had a history of coronary artery disease, 67% had chronic obstructive pulmonary disease, 61% had undergone prior aortic surgery, and 90% had an American Society of Anesthesiology score of 4 and above. The average Society for Vascular Surgery comorbidity score was 12 +/- 2 with a range of 9 to 14. Fifty-five percent of cases were symptomatic on presentation and 83% were done emergently. Seventy-six percent underwent debranching of the aortic arch, 17% of the visceral vessels, and 7% required both. Primary technical success was achieved in all cases and of these, 43% were staged. The 30-day mortality was 5%. Myocardial infarction developed in 5%, respiratory failure in 31%, cerebrovascular accident (stroke or transient ischemic attack) in 19%, and spinal cord ischemia with ensuant paraplegia occurred in 5% of patients. Fifty-eight percent of patients were discharged home, 11% required rehabilitation, and 29% were transferred to a skilled nursing facility. There was a significant association between visceral vessel debranching and both spinal cord ischemia (P = .004) and gastrointestinal complications (P = .005). On the other hand, there was no difference between staged and non-staged hybrid procedures. Hybrid procedures can successfully extend the range of patients suitable for a subsequent TEVAR. These procedures are associated with higher complication rates than isolated infrarenal

  5. Endovascular treatment of very small intracranial aneurysms

    DEFF Research Database (Denmark)

    Iskandar, A; Nepper-Rasmussen, J

    2011-01-01

    to large aneurysms (> 3 mm). However the data also suggest that endovascular treatment of very small aneurysms might be associated with an increased risk of procedural ruptures and mortality. At nine-month follow-up results indicate significantly less compaction in the very small aneurysms....... endovascular treatment was attempted in 956 consecutive intracranial aneurysms. Of 956 aneurysms, 111 aneurysms were very small aneurysms with a maximal diameter of 3 mm or less. We conducted a retrospective analysis of angiographic and clinical outcome following coiling of very small aneurysms...... aneurysms and less than 90% aneurysm occlusion in six aneurysms. Complications occurred in the treatment of 15 aneurysms, including eight procedural ruptures, six thromboembolic events and one case of early hemorrhage. Compared with larger aneurysms, treatment of very small aneurysms was associated...

  6. The endovascular treatment of brain arteriovenous malformations.

    Science.gov (United States)

    Valavanis, A; Yaşargil, M G

    1998-01-01

    Advances in superselective microcatheterization techniques, which took place in the past decade, established superselective endovascular exploration as an integral and indispensable tool in the pretherapeutic evaluation of brain AVMs. The strict and routine application of superselective angiography furthered our knowledge on the angioarchitecture of brain AVMs, including vascular composition of the nidus, types of feeding arteries and types and patterns of venous drainage. In addition, various types of weak angioarchitectural elements, such as flow-related aneurysms, intranidal vascular cavities and varix formation proximal to high-grade stenosis of draining veins, could be identified as factors predisposing for AVM rupture. A wide spectrum of secondary angiomorphological changes induced by the arteriovenous shunt of the nidus and occurring up- and downstream of the nidus have been identified as manifestations of high-flow angiopathy. These data help to better predict the natural history, understand the widely variable clinical presentation and to define therapeutic targets of brain AVMs. Correlation of the topography of the AVM as demonstrated by MR with the angioarchitecture as demonstrated by superselective angiography provided a system for topographic-vascular classification of brain AVMs, which proved very useful for patient selection and definition of therapeutic goals. This study showed, that 40% of patients with brain AVMs can be cured by embolization alone with a severe morbidity of 1.3% and a mortality of 1.3%. Part of theses patients can, however, be cured equally effective by microsurgery or radiosurgery. Which modality will be chosen for a particular patient will mainly depend on the locally available expertise and experience, but also on the preference of the patient following its comprehensive information about the chances for cure and the risks associated with each of these therapeutic modalities. Embolization has a significant role in the

  7. Intestinal infarction: A complication of endovascular therapy

    Energy Technology Data Exchange (ETDEWEB)

    England, Andrew [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom)]. E-mail: andrew.england@smtr.nhs.uk; Butterfield, John S. [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Sukumar, Sathi [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Thompson, David [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Roulson, Jo-An [Department of Histopathology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Pritchard, Susan [Department of Histopathology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom); Ashleigh, Raymond J. [Department of Radiology, South Manchester University Hospitals NHS Trust, Southmoor Road, Wythenshawe, Manchester M23 9LT (United Kingdom)

    2007-08-15

    This report presents a rare case of intestinal infarction following endovascular therapy. A female patient who had undergone an internal carotid artery stenting procedure presented suddenly with abdominal pain. Radiological and clinical examinations at the time suggested a picture of intestinal ischaemia, in view of the patient's general conditions and co-existing morbidities surgical intervention was not considered to be an option. The patient died 4 days after the carotid stenting procedure, post-mortem examination revealed infarction of the ileum and caecum. The learning outcomes are if performing endovascular therapy in a patient with diffuse atherosclerotic disease early consideration of intestinal ischaemia should be given to any patient who presents with acute post-procedural abdominal pain.

  8. Intestinal infarction: A complication of endovascular therapy

    International Nuclear Information System (INIS)

    England, Andrew; Butterfield, John S.; Sukumar, Sathi; Thompson, David; Roulson, Jo-An; Pritchard, Susan; Ashleigh, Raymond J.

    2007-01-01

    This report presents a rare case of intestinal infarction following endovascular therapy. A female patient who had undergone an internal carotid artery stenting procedure presented suddenly with abdominal pain. Radiological and clinical examinations at the time suggested a picture of intestinal ischaemia, in view of the patient's general conditions and co-existing morbidities surgical intervention was not considered to be an option. The patient died 4 days after the carotid stenting procedure, post-mortem examination revealed infarction of the ileum and caecum. The learning outcomes are if performing endovascular therapy in a patient with diffuse atherosclerotic disease early consideration of intestinal ischaemia should be given to any patient who presents with acute post-procedural abdominal pain

  9. Safety and efficacy of transhepatic and transsplenic access for endovascular management of portal vein complications after liver transplantation.

    Science.gov (United States)

    Ohm, Joon-Young; Ko, Gi-Young; Sung, Kyu-Bo; Gwon, Dong-Il; Ko, Heung Kyu

    2017-09-01

    The purpose of this article is to evaluate and compare the safety and efficacy of endovascular management of the portal vein (PV) via percutaneous transsplenic access versus percutaneous transhepatic access in liver transplantation (LT) recipients. A total of 18 patients who underwent endovascular management of PV via percutaneous transhepatic (n = 8) and transsplenic (n = 10) access were enrolled. Transsplenic access was chosen if the spleen was located in a normal position, the splenic vein (SpV) was preserved, and the target lesion did not involve confluence of the superior mesenteric and SpVs. Accessibility of the percutaneous transsplenic puncture was confirmed via ultrasound (US) in the angiography suite. All procedures were performed under local anesthesia. Percutaneous transhepatic or transsplenic access was performed using a 21-gauge Chiba needle under US and fluoroscopic guidance, followed by balloon angioplasty, stent placement, or variceal embolization. The access tract was embolized using coils and a mixture (1:2) of glue and ethiodized oil. Transhepatic or transsplenic access was successfully achieved in all patients. A total of 12 patients underwent stent placement; 3 had balloon angioplasty only; 2 had variceal embolization only; and 1 had variceal embolization followed by successful stent placement. Regarding major complications, 1 patient experienced a SpV tear with extravasation during transsplenic balloon angioplasty, which was successfully managed using temporary balloon inflation, followed by transfusion. Clinical success was achieved in 9 of 11 (82%) patients who exhibited clinical manifestations. The remaining 7 patients who underwent prophylactic endovascular management were healthy. In conclusion, endovascular management of PV via percutaneous transsplenic access is a relatively safe and effective alternative that does not damage the liver grafts of LT recipients. Liver Transplantation 23 1133-1142 2017 AASLD. © 2017 by the American

  10. Frequency of Helicobacter pylori in patients underwent endoscopy

    Directory of Open Access Journals (Sweden)

    Ahmet Tay

    2012-06-01

    Full Text Available Objectives: The aim of this study was to investigate thefrequency of Helicobacter pylori in patients underwent endoscopyeastern Anatolia.Materials and methods: The patients whose endoscopicantral biopsies were taken for any reason in our endoscopyunit in February-June 2010 period were includedand retrospectively investigated. The frequency of Helicobacterpylori was determined as separating the patientsaccording to general, sex and the age groups. Antral biopsieswere stained with hematoxylin-eosin and modified giemsamethod and examined under light microscope andreported as (+ mild, (++ moderate, (+++ severe positiveaccording to their intensities.Results: Biopsy specimens of 1298 patients were includedinto the study. The mean age was 47.5 ± 17.5 years(range 14-88 and 607 of these patients (47% were male.Histopathological evaluation revealed that, 918 of the patientswere (71% positive and 379 (29% were negativefor Helicobacter pylori. Approximately 60% of our patientshad mild, 29% had moderate and 11% had severe positivityfor Helicobacter pylori. No significant difference wasfound in the frequency of Helicobacter pylori betweenwomen and men. The frequencies of Helicobacter pyloriwere 73.2%, 71.5%, 68.6% and 70.4%, respectively, inthe age groups of 14-30 years, 31-45 years, 46-60 yearsand 61-88 years.Conclusion: The frequency of Helicobacter pylori was71% in Eastern Anatolia Region. No statistically significantdifference was found between genders and agegroups in term of the frequency of Helicobacter pylori.

  11. Gore excluder device with the C3 delivery system for management of abdominal aortic aneurysm

    OpenAIRE

    Morasch, Mark; Cheong J. Lee,; Mark L. Keldahl,

    2012-01-01

    Cheong J Lee, Mark L Keldahl, Mark D MoraschDivision of Vascular Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USAAbstract: The GORE Excluder stent-graft is one of the currently available devices approved by the US Food and Drug Administration for use in endovascular aortic repair. Recently, a new delivery system modification has been applied to the Excluder device which allows repositioning of the stent-graft to adjust for accurate proximal landing and facilitate...

  12. Current role of endovascular therapy in Marfan patients with previous aortic surgery

    Directory of Open Access Journals (Sweden)

    Ibrahim Akin

    2008-02-01

    Full Text Available Ibrahim Akin, Stephan Kische, Tim C Rehders, Tushar Chatterjee, Henrik Schneider, Thomas Körber, Christoph A Nienaber, Hüseyin InceDepartment of Medicine, Division of Cardiology at the University Hospital Rostock, Rostock School of Medicine, Ernst-Heydemann-Str. 6, 18057 Rostock, GermanyAbstract: The Marfan syndrome is a heritable disorder of the connective tissue which affects the cardiovascular, ocular, and skeletal system. The cardiovascular manifestation with aortic root dilatation, aortic valve regurgitation, and aortic dissection has a prevalence of 60% to 90% and determines the premature death of these patients. Thirty-four percent of the patients with Marfan syndrome will have serious cardiovascular complications requiring surgery in the first 10 years after diagnosis. Before aortic surgery became available, the majority of the patients died by the age of 32 years. Introduction in the aortic surgery techniques caused an increase of the 10 year survival rate up to 97%. The purpose of this article is to give an overview about the feasibility and outcome of stent-graft placement in the descending thoracic aorta in Marfan patients with previous aortic surgery.Keywords: Marfan syndrome, aortic dissection, root replacement, stent-graft, previous aortic surgery

  13. Benefit of endovascular stenting for aortic coarctation on systemic hypertension in adults.

    Science.gov (United States)

    Hamid, Tahir; Motwani, Manish; Schneider, Heiko; Dua, Jaspal Singh; Hoschtitzky, Andreas; Clarke, Bernard; Mahadevan, Vaikom S

    2015-12-01

    Endovascular stenting is a recognised treatment strategy for aortic coarctation (CoA) in adults. We assessed systemic hypertension control and the need for antihypertensive therapy after CoA stenting in adults. Data were collected prospectively on 54 patients (36 men; mean age: 34 ± 16 years) who underwent endovascular stenting for CoA over a 7-year period. Five patients were excluded as they did not attend follow-up appointments. Patients underwent clinical examination, including right arm systolic blood pressure (SBP) and 24-hour ambulatory blood pressure monitoring at baseline, 6-12 weeks and 9-12 months. There was a significant fall in mean peak-to-peak systolic gradient (PG) across the CoA after stenting (26 ± 11 mmHg vs. 5 ± 4 mmHg; P25 mmHg before stenting); baseline SBP was significantly higher in severe versus non-severe patients (160 mmHg vs. 148 mmHg; P=0.02). The absolute reduction in PG after stenting was significantly higher in the severe group (31 ± 7 mmHg vs. 14 ± 5 mmHg; P<0.0001), but there was no significant difference in SBP between groups at 6-12 weeks (141 mmHg vs. 135 mmHg; P=0.21) or 9-12 months (139 mmHg vs. 139 mmHg; P=0.96). Endovascular stenting of CoA results in a significant reduction in SBP at 6-12 weeks, which is sustained at 9-12 months, with similar outcomes in severe and non-severe CoA groups. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  14. Transjugular Endovascular Recanalization of Splenic Vein in Patients with Regional Portal Hypertension Complicated by Gastrointestinal Bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Xuefeng; Nie, Ling; Wang, Zhu; Tsauo, Jiaywei; Tang, Chengwei; Li, Xiao, E-mail: simonlixiao@126.com [West China Hospital, Sichuan University, Department of Gastroenterology (China)

    2013-05-02

    PurposeRegional portal hypertension (RPH) is an uncommon clinical syndrome resulting from splenic vein stenosis/occlusion, which may cause gastrointestinal (GI) bleeding from the esophagogastric varices. The present study evaluated the safety and efficacy of transjugular endovascular recanalization of splenic vein in patients with GI bleeding secondary to RPH.MethodsFrom December 2008 to May 2011, 11 patients who were diagnosed with RPH complicated by GI bleeding and had undergone transjugular endovascular recanalization of splenic vein were reviewed retrospectively. Contrast-enhanced computed tomography revealed splenic vein stenosis in six cases and splenic vein occlusion in five. Etiology of RPH was chronic pancreatitis (n = 7), acute pancreatitis with pancreatic pseudocyst (n = 2), pancreatic injury (n = 1), and isolated pancreatic tuberculosis (n = 1).ResultsTechnical success was achieved in 8 of 11 patients via the transjugular approach, including six patients with splenic vein stenosis and two patients with splenic vein occlusion. Two patients underwent splenic vein venoplasty only, whereas four patients underwent bare stents deployment and two covered stents. Splenic vein pressure gradient (SPG) was reduced from 21.5 ± 7.3 to 2.9 ± 1.4 mmHg after the procedure (P < 0.01). For the remaining three patients who had technical failures, splenic artery embolization and subsequent splenectomy was performed. During a median follow-up time of 17.5 (range, 3–34) months, no recurrence of GI bleeding was observed.ConclusionsTransjugular endovascular recanalization of splenic vein is a safe and effective therapeutic option in patients with RPH complicated by GI bleeding and is not associated with an increased risk of procedure-related complications.

  15. Open Embolectomy of Large Vessel Occlusion in the Endovascular Era: Results of a 12-Year Single-Center Experience.

    Science.gov (United States)

    Horiuchi, Tetsuyoshi; Nitta, Junpei; Miyaoka, Yoshinari; Nagm, Alhusain; Tsutsumi, Keiji; Ito, Kiyoshi; Hongo, Kazuhiro

    2017-06-01

    Mechanical endovascular embolectomy using stent retrievers has gained popularity for treatment of large vessel occlusion in acute ischemic stroke. Use of open embolectomy as a direct surgical treatment has been limited, likely owing to the technical difficulty, therapeutic time window, and time-consuming procedure. We retrospectively reviewed clinical and radiographic records of patients who underwent open embolectomy for major artery occlusion at an acute stage. Clinical features, complications, and outcome of patients were analyzed. From January 2004 to September 2016, 153 patients underwent 157 open embolectomies for major artery occlusion. Complete recanalization was achieved in 96.2% of patients. A favorable outcome was observed in 43.9%. Cerebral aneurysm along the occluded artery was observed in 11 patients with 12 aneurysms. Open embolectomy resulted in a high complete recanalization rate with an acceptable safety profile. Open embolectomy is a safe and durable method of cerebral recanalization in patients with embolic stroke and can be considered as a potential treatment if endovascular embolectomy cannot be performed. The details of the occluded arteries presented here will be useful for endovascular surgeons to prevent complications. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Endovascular treatment of cerebral aneurysms - a cost analysis | Le ...

    African Journals Online (AJOL)

    The average cost for endovascular treatment per patient was R37 041. Surgical treatment was more expensive at R44 104, a difference of 16%. Conclusions. Despite the high cost of endovascular devices, appropriate use of this technology ultimately offers less expensive treatment than microsurgical clipping of aneurysms.

  17. The creation of the optimal dedicated endovascular suite

    NARCIS (Netherlands)

    Sikkink, C. J. J. M.; Reijnen, M. M. P. J.; Zeebregts, C. J.

    Background. During the last decade endovascular therapy has been established as an alternative treatment for a variety of vascular diseases. Neither the classic operating room (OR), nor the conventional angiography suite is optimal for both open surgery and endovascular procedures. Important issues

  18. Incidence of systemic inflammatory response syndrome after endovascular aortic repair

    DEFF Research Database (Denmark)

    De La Motte, L; Vogt, K; Jensen, Leif Panduro

    2011-01-01

    AIM: The aim of this study was to estimate the incidence of the post-implantation syndrome/systemic inflammatory response syndrome (SIRS) after endovascular aortic repair. METHODS: All patients, undergoing elective primary endovascular repair of an asymptomatic infrarenal abdominal aortic aneurysm...

  19. Simulation and augmented reality in endovascular neurosurgery: lessons from aviation.

    Science.gov (United States)

    Mitha, Alim P; Almekhlafi, Mohammed A; Janjua, Major Jameel J; Albuquerque, Felipe C; McDougall, Cameron G

    2013-01-01

    Endovascular neurosurgery is a discipline strongly dependent on imaging. Therefore, technology that improves how much useful information we can garner from a single image has the potential to dramatically assist decision making during endovascular procedures. Furthermore, education in an image-enhanced environment, especially with the incorporation of simulation, can improve the safety of the procedures and give interventionalists and trainees the opportunity to study or perform simulated procedures before the intervention, much like what is practiced in the field of aviation. Here, we examine the use of simulators in the training of fighter pilots and discuss how similar benefits can compensate for current deficiencies in endovascular training. We describe the types of simulation used for endovascular procedures, including virtual reality, and discuss the relevant data on its utility in training. Finally, the benefit of augmented reality during endovascular procedures is discussed, along with future computerized image enhancement techniques.

  20. Comparison of Total Arch and Partial Arch Transposition During Hybrid Endovascular Repair for Aortic Arch Disease.

    Science.gov (United States)

    Kang, W C; Ko, Y-G; Oh, P C; Shin, E K; Park, C-H; Choi, D; Youn, Y N; Lee, D Y

    2016-08-01

    Total arch transposition (TAT) during hybrid endovascular repair for aortic arch disease is believed to allow a better landing zone, but also to be associated with higher peri-operative mortality than partial arch transposition (PAT). Information on this issue is limited. This study was a retrospective analysis. All 53 consecutive patients with aortic arch disease (41 males, mean age 65.0 years) who underwent hybrid endovascular repair with TAT (zone 0, n=20) or PAT (zone 1 or 2, n=33) from 2008 to 2014 were analyzed retrospectively. The peri-operative and late outcomes of these two groups were compared. Baseline characteristics, including EuroSCORE II results, were similar in the two groups. After procedures, peri-operative mortalities and stroke rates were similar in the two groups (5.0% vs. 9.1%, p=1.000, and 10.0% vs. 6.1%, p=.627). Interestingly, all four strokes occurred in patients with a type III aortic arch irrespective of transposition type. Primary success rates (80.0% vs. 69.7%, p=.527) and type I endoleak incidences (20.0% vs. 27.3%, p=.744) were not significantly different. During follow up (mean duration 36.9 months), overall survival (89.7% vs. 87.4% at 1 year and 89.7% vs. 79.3% at 3 years; p=.375) and re-intervention free survival rates (78.6% vs. 92.0% at 1 year; 72.0% vs. 62.2% at 3 years, p=.872) were similar in the two groups. Morbidity and mortality were high within the first year of hybrid endovascular therapy for aortic arch disease, implying that candidates for hybrid procedures need to be selected carefully. Hybrid endovascular repair with TAT was found to have peri-operative mortality, stroke, and long-term survival rates comparable with PAT, so hybrid endovascular repair may be considered, irrespective of type of arch reconstruction, when clinically indicated. Copyright © 2016 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Geometric Deformations of the Thoracic Aorta and Supra-Aortic Arch Branch Vessels Following Thoracic Endovascular Aortic Repair.

    Science.gov (United States)

    Ullery, Brant W; Suh, Ga-Young; Hirotsu, Kelsey; Zhu, David; Lee, Jason T; Dake, Michael D; Fleischmann, Dominik; Cheng, Christopher P

    2018-04-01

    To utilize 3-D modeling techniques to better characterize geometric deformations of the supra-aortic arch branch vessels and descending thoracic aorta after thoracic endovascular aortic repair. Eighteen patients underwent endovascular repair of either type B aortic dissection (n = 10) or thoracic aortic aneurysm (n = 8). Computed tomography angiography was obtained pre- and postprocedure, and 3-D geometric models of the aorta and supra-aortic branch vessels were constructed. Branch angle of the supra-aortic branch vessels and curvature metrics of the ascending aorta, aortic arch, and stented thoracic aortic lumen were calculated both at pre- and postintervention. The left common carotid artery branch angle was lower than the left subclavian artery angles preintervention ( P Supra-aortic branch vessel angulation remains relatively static when proximal landing zones are distal to the left common carotid artery.

  2. Flow and wall shear stress characterization following endovascular aneurysm repair and endovascular aneurysm sealing in an infrarenal aneurysm model

    NARCIS (Netherlands)

    Boersen, Johannes Thomas; Groot Jebbink, Erik; Versluis, Michel; Slump, Cornelis H.; Ku, David N.; de Vries, Jean-Paul P.M.; Reijnen, Michel M.P.J.

    2017-01-01

    Background Endovascular aneurysm repair (EVAR) with a modular endograft has become the preferred treatment for abdominal aortic aneurysms. A novel concept is endovascular aneurysm sealing (EVAS), consisting of dual endoframes surrounded by polymer-filled endobags. This dual-lumen configuration is

  3. Endovascular treatment for intracranial infectious aneurysms Tratamento endovascular de aneurismas infecciosos intracranianos

    Directory of Open Access Journals (Sweden)

    Eduardo Wajnberg

    2008-12-01

    Full Text Available OBJETIVE: To re-enforce an alternative, less aggressive treatment modality in the management of intracranial infectious aneurysms. METHOD: We present a series of five patients with infectious endocarditis and intracranial infectious aneurysms (mycotic aneurysms managed by means of endovascular treatment. RESULTS: Endovascular treatment was executed technically uneventfully in all patients. Three patients had favorable clinical outcome: two were classified as Glasgow Outcome Scale 4/5, and one had total neurological recovery (GOS 5/5. Two patients died (GOS 1/5, one in consequence of the initial intracranial bleeding and the other after cardiac complications from endocarditis and open-heart surgery. CONCLUSION: Endovascular techniques are an expanding option for the treatment of IIAs. It has been especially useful for infectious endocarditis patients with IIA, who will be submitted to cardiac surgery with cardiopulmonary bypass and anticoagulation, with the risk of intracranial bleeding.OBJETIVO: Enfatizar o método endovascular como uma opção de tratamento alternativa e menos agressiva no tratamento de aneurismas infecciosos intracranianos. MÉTODO: Apresentamos uma série de cinco pacientes com endocardite infecciosa e aneurismas infecciosos intra-cranianos (aneurismas micóticos tratados através da via endovascular. RESULTADOS: O tratamento endovascular teve sucesso técnico e sem intercorrências relacionadas ao cateterismo em todos os casos. Três pacientes tiveram desfecho clínico favorável: dois com escala de regeneração de Glasgow 4/5 e um com recuperação neurológica completa (GOS 5/5. Dois pacientes tiveram desfecho desfavorável (GOS 1/5, um devido às conseqüências do sangramento intracraniano inicial e outro devido a complicações cardíacas da endocardite e cirurgia de troca valvar. CONCLUSÃO: As técnicas endovasculares são uma nova opção de tratamento dos aneurismas infecciosos intracranianos. Ela é especialmente

  4. Tratamento endovascular de angiomiolipoma renal por embolização arterial seletiva Endovascular treatment of renal angiomiolipoma by selective arterial embolization

    Directory of Open Access Journals (Sweden)

    Renato Menezes Palácios

    2012-12-01

    Full Text Available Relata-se um caso de um paciente com queixa principal de dor lombar à esquerda, portador de angiomiolipomas renais (AMLRs bilaterais, com a lesão mais volumosa de 6,2 cm em seu maior diâmetro, submetido a tratamento endovascular por embolização arterial superseletiva com microesferas. Os AMLRs são tumores benignos raros. A maioria é esporádica, enquanto uma minoria está associada à Esclerose Tuberosa Complexa (ETC. Os AMLRs maiores do que 4 cm devem ser tratados devido ao maior risco de complicações, principalmente hemorrágicas. A embolização arterial seletiva (EAS é um tratamento efetivo e seguro para os AMLRs.We report a case of a patient with a major complaint of left lumbar pain, diagnosed with bilateral renal angiomyolipomas (AMLRs, with the most voluminous lesion of 6.2 cm in its largest diameter, underwent endovascular superselective arterial embolization with microspheres. The AMLRs are rare benign tumors. Most are sporadic, while a minority is associated with Tuberous Sclerosis Complex (ETC. The AMLRs larger than 4 cm must be treated due to higher risk of complications, especially hemorrhagic. A selective arterial embolization (EAS is an effective and safe treatment for AMLRs.

  5. Endovascular treatment of type B dissection in patients with Marfan syndrome: mid-term outcomes and aortic remodeling.

    Science.gov (United States)

    Eid-Lidt, Guering; Gaspar, Jorge; Meléndez-Ramírez, Gabriela; Cervantes S, Jorge; González-Pacheco, Hector; Dámas de Los Santos, Félix; Meave-González, Aloha; Ramírez Marroquín, Samuel

    2013-12-01

    To evaluate the mid-term outcomes, and the aortic remodeling in Marfan syndrome (MFS) patients with type B dissection that were treated with endovascular repair. MFS is a relative contraindication to thoracic endovascular aortic repair (TEVAR). Mid-term aortic outcomes data in MFS after TEVAR are limited, and the occurrence of late events remains unclear. Of 89 patients that underwent TEVAR between September 2002 and February 2011, 10 patients with mid-term follow-up fulfilled the Ghent criteria for MFS and complicated type B dissection. High risk for open surgery was documented in 90%. The mean age was 35.1 ± 9.4 years and all patients presented with acute aortic syndrome complicating a chronic type B dissection (DeBakey type IIIb). Five patients underwent a Bentall surgical procedure previous to endovascular repair, and in four patients initial TEVAR was followed by surgery of the ascending aorta. Treatment was limited to endovascular repair in only one patient. In-hospital mortality was 10%. At a mean follow-up of 59.6 ± 38.9 months, the cumulated mortality was of 20% and late mortality 11.1%. The rate of secondary endoleak was 44.4%, and late reintervention of 33.3%. Survival freedom from cardiovascular death at 8 years was 80.0%, and positive remodeling was documented in 37.5% of patients. Our results suggest that TEVAR is feasible, safe, and associated with a high reintervention rate and reduced rate of positive aortic remodeling in patients with Marfan syndrome. Survival at 8 years was comparable to contemporary series of open repair. Copyright © 2013 Wiley Periodicals, Inc.

  6. Endovascular Management of Patients with Head and Neck Cancers Presenting with Acute Hemorrhage: A Single-Center Retrospective Study

    Energy Technology Data Exchange (ETDEWEB)

    Vilas Boas, P. P.; Castro-Afonso, L. H. de; Monsignore, L. M.; Nakiri, G. S. [University of São Paulo, Division of Interventional Neuroradiology, Ribeirão Preto Medical School (Brazil); Mello-Filho, F. V. de [University of São Paulo, Department of Ophthalmology, Otorhinolaryngology and Head and Neck Surgery, Ribeirão Preto Medical School (Brazil); Abud, D. G., E-mail: dgabud@fmrp.usp.br [University of São Paulo, Division of Interventional Neuroradiology, Ribeirão Preto Medical School (Brazil)

    2017-04-15

    PurposeAcute hemorrhage associated with cancers of the head and neck is a life-threatening condition that requires immediate action. The aim of this study was to assess the safety and efficacy of endovascular embolization for acute hemorrhage in patients with head and neck cancers.Materials and MethodsData were retrospectively collected from patients with head and neck cancers who underwent endovascular embolization to treat acute hemorrhage. The primary endpoint was the rate of immediate control of hemorrhage during the first 24 h after embolization. The secondary endpoints were technical or clinical complications, rate of re-hemorrhage 24 h after the procedure, time from embolization to re-hemorrhage, hospitalization time, mortality rate, and time from embolization to death.ResultsFifty-one patients underwent endovascular embolization. The primary endpoint was achieved in 94% of patients. The rate of technical complications was 5.8%, and no clinical complication was observed. Twelve patients (23.5%) had hemorrhage recurrence after an average time of 127.5 days. The average hospitalization time was 7.4 days, the mortality rate during the follow-up period was 66.6%, and the average time from embolization to death was 132.5 days.ConclusionEndovascular embolization to treat acute hemorrhage in patients with head and neck cancers is a safe and effective method for the immediate control of hemorrhage and results in a high rate of hemorrhage control. Larger studies are necessary to determine which treatment strategy is best for improving patient outcomes.

  7. Endovascular Management of Patients with Head and Neck Cancers Presenting with Acute Hemorrhage: A Single-Center Retrospective Study

    International Nuclear Information System (INIS)

    Vilas Boas, P. P.; Castro-Afonso, L. H. de; Monsignore, L. M.; Nakiri, G. S.; Mello-Filho, F. V. de; Abud, D. G.

    2017-01-01

    PurposeAcute hemorrhage associated with cancers of the head and neck is a life-threatening condition that requires immediate action. The aim of this study was to assess the safety and efficacy of endovascular embolization for acute hemorrhage in patients with head and neck cancers.Materials and MethodsData were retrospectively collected from patients with head and neck cancers who underwent endovascular embolization to treat acute hemorrhage. The primary endpoint was the rate of immediate control of hemorrhage during the first 24 h after embolization. The secondary endpoints were technical or clinical complications, rate of re-hemorrhage 24 h after the procedure, time from embolization to re-hemorrhage, hospitalization time, mortality rate, and time from embolization to death.ResultsFifty-one patients underwent endovascular embolization. The primary endpoint was achieved in 94% of patients. The rate of technical complications was 5.8%, and no clinical complication was observed. Twelve patients (23.5%) had hemorrhage recurrence after an average time of 127.5 days. The average hospitalization time was 7.4 days, the mortality rate during the follow-up period was 66.6%, and the average time from embolization to death was 132.5 days.ConclusionEndovascular embolization to treat acute hemorrhage in patients with head and neck cancers is a safe and effective method for the immediate control of hemorrhage and results in a high rate of hemorrhage control. Larger studies are necessary to determine which treatment strategy is best for improving patient outcomes.

  8. Endovascular treatment of intracranial aneurysms: diversity in treatment techniques of varying anatomical presentations.

    Science.gov (United States)

    Putu, Patriawan; Firman, Sitanggang; Ismail, Mohd Redzuan; Nik-Ismail, Nik Azuan; Yaacob, Nur Yazmin; Muda, Ahmad Sobri

    2014-01-01

    We discuss and illustrate various endovascular treatment options for intracranial aneurysms, to reflect common technique used in endovascular treatment of brain aneurysm. We select five cases of various aneurysm types to show assortments of endovascular treatment (EVT) are performed. Selective catheterization of the intracranial aneurysms and endovascular treatments are technically feasible, offering a viable alternative to the surgical approach. We discuss the radiographic features, clinical presentation, and strategies of endovascular treatment of intracranial aneurysms.

  9. Endovascular Treatment of Unruptured Intracranial Aneurysms

    Science.gov (United States)

    Yue, W.

    2011-01-01

    Summary We report the clinical and angiographic results of endovascular treatment of unruptured intracranial aneurysms. Over a three-year period, 80 unruptured aneurysms in 74 patients were electively treated with endovascular management. One aneurysm was diagnosed during investigations for a second ruptured aneurysm, 54 aneurysms were incidentally discovered, 18 aneurysms presented with symptoms of mass effect and seven aneurysms presented with symptoms of brain stem ischemia. Mean size of the 80 unruptured aneurysms was 12.5±8.0 mm (range, 2-39 mm). Thirty-six aneurysms (45%) were small (<10 mm), 38 aneurysms (47.5%) were large (10-25 mm), and six aneurysms (7.5%) were giant (25-39 mm). Forty-eight wide-necked aneurysms (60%) were coiled with the aid of a supporting device. The mortality rate was 1.25%, and the overall morbidity was 1.25%. Of these, one of the patients suffered a stroke, leading to severe disability (1.25%). In one patient, the aneurysm ruptured during treatment, resulting in death. Initial aneurysm occlusion was complete (100%) in 76.25% aneurysms, nearly complete (90%-98%) in 10% aneurysms and incomplete (60%-85%) in 13.75% aneurysms. Follow-up angiography was available in 67 patients with 73 treated aneurysms (91.25%) from one to 36 months (mean 9.3 months); partial reopening occurred in 7.5%, mainly large and giant aneurysms (5.5%). Additional coiling was performed in four aneurysms. There were no complications in additional treatments. At 14.1-month clinical follow-up (range, 2 to 36 months), mRS score was 0 in 78.75% patients, 1 in 10% patients, 2 in 8.75% and 3 in 1.25%. There was no aneurysmal rupture during the follow-up period. Endovascular treatment of unruptured intracranial aneurysms has low procedural mortality and morbidity rates. PMID:22192544

  10. Advances in peripheral arterial disease endovascular revascularization.

    Science.gov (United States)

    Panico, Ambrose; Jafferani, Asif; Shah, Falak; Dieter, Robert S

    2015-02-01

    Significant advances have been made in the endovascular treatment of lower extremity arterial occlusive disease. Since the 2011 update, technologies has developed and allowed for the revascularization of complex vascular lesions. Although this technical success is encouraging, these technologies must provide measurable long-term clinical success at a reasonable cost. Large, randomized, controlled trials need to be designed to focus on clinical outcomes and success rates for treatment. These future studies will serve as the guide by which clinicians can provide the most successful clinical and cost effect care in treating patients with lower-extremity peripheral artery disease. Published by Elsevier Inc.

  11. Open versus endovascular aneurysm repair trial review.

    Science.gov (United States)

    Weinkauf, Craig; George, Elizabeth; Zhou, Wei

    2017-11-01

    The Open versus Endovascular Aneurysm Repair trial is the only randomized controlled trial that is funded by the federal government to evaluate the treatment outcomes of infrarenal abdominal aortic aneurysms. Since the initial publication, multiple post-hoc analyses have become available. This review summarizes these data, focusing on the primary outcome measures (ie, overall survival) and several key secondary outcomes including aneurysm-related death, age consideration, secondary procedures, and endoleaks. Cost-effectiveness of each treatment modality and the limitations of OVER trial also are discussed critically in this review. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Outcomes of infrageniculate retrograde versus transfemoral access for endovascular intervention for chronic lower extremity ischemia.

    Science.gov (United States)

    Taha, Ashraf G; Abou Ali, Adham N; Al-Khoury, George; Singh, Michael J; Makaroun, Michel S; Avgerinos, Efthymios D; Chaer, Rabih A

    2018-03-31

    Retrograde infrageniculate access is an alternative treatment strategy for patients who have failed to respond to antegrade endovascular intervention. This study compares the outcomes of infrageniculate retrograde arterial access with the conventional transfemoral access for the endovascular management of chronic lower extremity ischemia. This was a retrospective single-center review of retrograde endovascular intervention (REI) from 2012 to 2016. Indications for intervention, comorbidities, complications, procedural success, limb outcomes, and mortality were analyzed. Technical failure was defined as the inability to complete the procedure because of failed access or unsuccessful recanalization. Infrageniculate access and transfemoral access were obtained with ultrasound or angiographic roadmap guidance. Patency rates were calculated for technically successful interventions. There were 47 patients (85% presenting with critical limb ischemia) who underwent sheathless REI after failed antegrade recanalization of TransAtlantic Inter-Society Consensus class D infrainguinal lesions, whereas 93 patients (83% with critical limb ischemia) underwent standard transfemoral access. There were 16 (34%) femoropopliteal, 14 (30%) tibial, and 17 (36%) multilevel interventions in the retrograde group compared with 41 (41%) femoropopliteal, 20 (20%) tibial, and 39 (39%) multilevel interventions in the transfemoral group. Access sites for the retrograde group included the dorsalis pedis (26%), midcalf peroneal (24%), anterior tibial (22%), posterior tibial (26%), and popliteal (2%) arteries. Overall technical success was achieved in 57% of the retrograde group compared with 78% of the transfemoral group. Mean follow-up was 20 months (range, 1-45 months). There were no significant differences in the primary patency rates between the two groups at 1 year and 2 years. The primary assisted patency rates were significantly better in the transfemoral group at 1 year (66% vs 46%; P

  13. Perioperative and Late Outcomes after Endovascular Treatment for Isolated Iliac Artery Aneurysms.

    Science.gov (United States)

    Bianchini Massoni, Claudio; Freyrie, Antonio; Gargiulo, Mauro; Tecchio, Tiziano; Mascoli, Chiara; Gallitto, Enrico; Faggioli, Gianluca; Pini, Rodolfo; Azzarone, Matteo; Perini, Paolo; Stella, Andrea

    2017-10-01

    The aim of the study is to report early and follow-up outcomes of the endovascular treatment with iliac endografts for isolated iliac artery aneurysms (IIAAs). Records of patients who underwent elective endovascular repair for IIAA (both primary and para-anastomotic) from 2005 to 2015 in 2 Italian centers were retrospectively examined. Demographic data, preoperative patient comorbidities, iliac aneurysm characteristics, contralateral iliac axis involvement, patency of hypogastric arteries and inferior mesenteric artery (IMA), and data of endovascular treatment were obtained for analysis. Early end points were technical success (TS), perioperative morbidity, clinical success (CS), freedom from reintervention (FFR) and survival. Follow-up end points were CS, FFR, survival, evolution of the aneurysmal sac, and endoleak (EL). Thirty-two IIAAs were treated through an endovascular approach in 30 patients (male 96.7%; mean age 74.2 years ± 7.6, range 55-86). Aneurysms were para-anastomotic in 11 (34.4%) cases. Mean diameter was 42.9 ± 15.6 mm (range 30-100). Twenty (62.5%) aneurysms involved exclusively the common iliac artery, 7 (21.9%) the hypogastric, and 5 (15.6%) both arteries. Ipsilateral hypogastric artery was stenotic or occluded in 4 (12.5%) and 1 (3.1%) patient, respectively. Contralateral hypogastric artery was occluded in 2 (6.3%) cases. IMA was patent in 9 (30%) patients. The ostium of the hypogastric artery was preserved in 5 cases (15.6%) and voluntarily covered in 27 (84.4%). Endovascular embolization of hypogastric artery was obtained with a plug device in 8 cases (25%). Hypogastric surgical revascularization was performed in 2 cases (6.3%). TS was 96.9%. Thirty-day morbidity was 6.3% (2/32). CS was 96.9% (1 endograft limb stenosis). Thirty-day FFR was 90.6% (1 transluminal angioplasty, 2 inguinal revisions). Thirty-day survival was 100%. At 1, 3, and 6 years, CS was 93.4%, 85.6%, and 85.6%, respectively (1 endograft limb thrombosis, 1 endograft

  14. Endovascular Embolisation of Visceral Artery Pseudoaneurysms

    International Nuclear Information System (INIS)

    Khattak, Yasir Jamil; Alam, Tariq; Hamid Shoaib, Rana; Sayani, Raza; Haq, Tanveer-ul; Awais, Muhammad

    2014-01-01

    Objective. To evaluate the technical success, safety, and outcome of endovascular embolization procedure in management of visceral artery pseudoaneurysms. Materials and Methods. 46 patients were treated for 53 visceral pseudoaneurysms at our institution. Preliminary diagnostic workup in all cases was performed by contrast enhanced abdominal CT scan and/or duplex ultrasound. In all patients, embolization was performed as per the standard departmental protocol. For data collection, medical records and radiology reports of all patients were retrospectively reviewed. Technical success, safety, and outcome of the procedure were analyzed. Results. Out of 46 patients, 13 were females and 33 were males. Mean patient age was 44.79 ± 13.9 years and mean pseudoaneurysm size was 35 ± 19.5 mm. Technical success rate for endovascular visceral pseudoaneurysm coiling was 93.47% (n = 43). Complication rate was 6.52% (n = 3). Followup was done for a mean duration of 21 ± 1.6 months (0.5–69 months). Complete resolution of symptoms or improvement in clinical condition was seen in 36 patients (80%) out of those 45 in whom procedure was technically successful. Conclusion. Results of embolization of visceral artery pseudoaneurysms with coils at our center showed high success rate and good short term outcome

  15. Endovascular strategy for unruptured cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Mangiafico, S., E-mail: mangiax@libero.it [Interventional Neuroradiology Unit, Careggi University Hospital, Florence (Italy); Guarnieri, G., E-mail: gianluigiguarnieri@hotmail.it [Neuroradiology Service, Cardarelli Hospital, Naples (Italy); Consoli, A., E-mail: onemed21@gmail.com [Interventional Neuroradiology Unit, Careggi University Hospital, Florence (Italy); Ambrosanio, G., E-mail: gambros@libero.it [Neuroradiology Service, Cardarelli Hospital, Naples (Italy); Muto, M., E-mail: mutomar@tiscali.it [Neuroradiology Service, Cardarelli Hospital, Naples (Italy)

    2013-10-01

    The treatment of unruptured intracranial aneurysms (UIAs) remains complex and not clearly defined. While for ruptured intracranial aneurysms the management and the treatment option (surgery or endovascular treatment) are well defined by several trials, for asymptomatic UIAs the best management is still currently uncertain. The rationale to treat an UIA is to prevent the rupture and its consequent SAH and all complications derived from hemorrhage or reduce/eliminate neurological palsy. Although this statement is correct, the indication to treat an UIA should be based on a correct balance between the natural history of UIA and treatment risk. Patient's clinical history, aneurysm characteristics, and strategy management influence the natural history of UIAs and treatment outcomes. In the last 10 years and more, two important large multicenter studies were performed in order to analysis of all these factors and to evaluate the best treatment option for UIAs. The aim of this paper is to try to synthesize the possible indications to the endovascular treatment (EVT), when and how to treat an UIA.

  16. Endovascular Treatment of AICA Flow Dependent Aneurysms

    Science.gov (United States)

    Mahmoud, M.; El Serwi, A.; Alaa Habib, M.; Abou Gamrah, S.

    2012-01-01

    Summary Peripheral anterior inferior cerebellar artery (AICA) aneurysms are rare, accounting for less than 1% of all cerebral aneurysms. To our knowledge 34 flow-related cases including the present study have been reported in the literature. Three patients harbouring four flow dependent aneurysms were referred to our institution. Two patients presented with subarachnoid hemorrhage, one presented with cerebellar manifestations. They were all treated by endovascular embolization of the aneurysm as well as the parent artery using liquid embolic material. Two cases were embolized using NBCA, Onyx was used in the third case. No bleeding or rebleeding were encountered during the follow-up period which ranged from five to nine months. One patient developed facial palsy, cerebellar symptoms and sensorineural hearing loss. The remaining two cases did not develop any post treatment neurological complications. Endovascular management of flow-dependent AICA aneurysms by parent artery occlusion is feasible and efficient in terms of rebleeding prevention. Post embolization neurological complications are unpredictable. This depends upon the adequacy of collaterals from other cerebellar arteries. PMID:23217640

  17. Endovascular aortic repair: First twenty years

    Directory of Open Access Journals (Sweden)

    Končar Igor

    2012-01-01

    Full Text Available Endovascular aortic/aneurysm repair (EVAR was introduced into clinical practice at the beginning of the nineties. Its fast development had a great influence on clinicians, vascular surgeons and interventional radiologists, educational curriculums, patients, industry and medical insurance. The aim of this paper is to present the contribution of clinicians and industry to the development and advancement of endovascular aortic repair over the last 20 years. This review article presents the development of EVAR by focusing on the contribution of physicians, surgeons and interventional radiologists in the creation of the new field of vascular surgery termed hybrid vascular surgery, and also the contribution of technological advancement by a significant help of industrial representatives – engineers and their counselors. This article also analyzes studies conducted in order to compare the successfulness of EVAR with up-to-now applied open surgical repair of aortic aneurysms, and some treatment techniques of other aortic diseases. During the first two decades of its development the EVAR method was rapidly progressing and was adopted concurrently with the expansion of technology. Owing to large randomized studies, early and long-term results indicate specific complications of this method, thus influencing further technological improvement and defining risk patients groups in whom the use of the technique should be avoided. Good results are insured only in centers, specialized in vascular surgery, which have on their disposal adequate conditions for solving all complications associated with this method.

  18. Endovascular strategy for unruptured cerebral aneurysms.

    Science.gov (United States)

    Mangiafico, S; Guarnieri, G; Consoli, A; Ambrosanio, G; Muto, M

    2013-10-01

    The treatment of unruptured intracranial aneurysms (UIAs) remains complex and not clearly defined. While for ruptured intracranial aneurysms the management and the treatment option (surgery or endovascular treatment) are well defined by several trials, for asymptomatic UIAs the best management is still currently uncertain. The rationale to treat an UIA is to prevent the rupture and its consequent SAH and all complications derived from hemorrhage or reduce/eliminate neurological palsy. Although this statement is correct, the indication to treat an UIA should be based on a correct balance between the natural history of UIA and treatment risk. Patient's clinical history, aneurysm characteristics, and strategy management influence the natural history of UIAs and treatment outcomes. In the last 10 years and more, two important large multicenter studies were performed in order to analysis of all these factors and to evaluate the best treatment option for UIAs. The aim of this paper is to try to synthesize the possible indications to the endovascular treatment (EVT), when and how to treat an UIA. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Endovascular Management of Central Retinal Arterial Occlusion.

    Science.gov (United States)

    Agarwal, Nitin; Gala, Nihar B; Baumrind, Benjamin; Hansberry, David R; Thabet, Ahmad M; Gandhi, Chirag D; Prestigiacomo, Charles J

    2016-11-01

    Central retinal artery occlusion (CRAO) is an ophthalmologic emergency due to the sudden cessation of circulation to the inner retinal layer. Without immediate treatment, permanent blindness may ensue. Several treatment options exist, ranging from noninvasive medical management to thrombolysis. Nonetheless, ongoing debate exists regarding the best therapeutic strategy. The authors present the case of a 78-year-old woman with a medical history of hypercholesterolemia and rheumatoid arthritis who experienced complete loss of vision in her left eye. Following ophthalmologic evaluation demonstrating left CRAO, anterior chamber paracentesis was performed. Endovascular intervention was performed via local intra-arterial fibrinolysis with alteplase. Her vision returned to 20/20 following the procedure. In general, conventional therapies have not significantly improved patient outcomes. Several management options exist for CRAO. In general, conservative measures have not been reported to yield better patient outcomes as compared to the natural history of this medical emergency. Endovascular approaches are another option as observed with this case reported. In cases of CRAO, therapeutic strategies such as intra-arterial fibrinolysis utilize a local infusion of reactive tissue plasminogen activator directly at the site of occlusion via catheterization of the ophthalmic artery. Although several case series do show promising results after treating CRAO with intra-arterial fibrinolysis, further studies are required given the reports of complications.

  20. Emergency endovascular coiling of a ruptured giant splenic artery aneurysm

    Directory of Open Access Journals (Sweden)

    Erika Wernheden, MD

    2017-12-01

    Full Text Available Splenic artery aneurysms (SAAs are the third most common abdominal aneurysm. Endovascular treatment of SAAs is preferred, and coiling is the most commonly used technique. Ruptured giant (>5 cm SAAs are usually treated with open surgery including splenectomy. We present a rare case of a ruptured 15-cm giant SAA in an 84-year-old woman treated successfully with emergency endovascular coiling. To our knowledge, this is one of the few reports of emergency endovascular treatment for ruptured giant SAA.

  1. Randomized, multicenter study comparing expanded polytetrafluoroethylene-covered endoprosthesis placement with percutaneous transluminal angioplasty in the treatment of superficial femoral artery occlusive disease.

    Science.gov (United States)

    Saxon, Richard R; Dake, Michael D; Volgelzang, Robert L; Katzen, Barry T; Becker, Gary J

    2008-06-01

    To compare the safety and effectiveness of the Viabahn endoprosthesis with that of percutaneous transluminal angioplasty (PTA) alone in the treatment of symptomatic peripheral arterial disease (PAD) affecting the superficial femoral artery (SFA). From 1998 to 1999, patients with symptomatic SFA PAD were enrolled in a prospective, multicenter randomized study and underwent either PTA alone (n = 100) or PTA followed by stent-graft placement (expanded polytetrafluoroethylene/nitinol self-expanding stent-graft) (n = 97) for stenoses or occlusions of the SFA that were 13 cm long or shorter. At baseline, there were no significant differences between the PTA and stent-graft treatment groups, including chronic limb ischemia status and treated lesion length. The stent-graft group had a significantly higher technical success rate (95% vs 66%, P late major adverse events. In this multicenter study, the patency, technical success, and clinical status results obtained with stent-grafts were superior to those obtained with PTA alone.

  2. Endovascular recanalization of native chronic total occlusions in patients with failed lower-extremity bypass grafts.

    Science.gov (United States)

    Wrigley, Clinton W; Vance, Ansar; Niesen, Timothy; Grilli, Christopher; Velez, J Daniel; Agriantonis, Demetrios J; Kimbiris, George; Garcia, Mark J; Leung, Daniel A

    2014-09-01

    To investigate the feasibility, safety, and outcome of endovascular recanalization of native chronic total occlusions (CTOs) in patients with failed lower-extremity bypass grafts. Retrospective review of 19 limbs in 18 patients with failed lower-extremity bypass grafts that underwent recanalization of native arterial occlusions between February 2009 and April 2013 was performed. Nine of the limbs presented with acute ischemia and 10 presented with chronic ischemia, including eight with critical limb ischemia and two with disabling claudication. The mean patency of the failed bypass grafts (63% venous) was 27 months. All limbs had Transatlantic Inter-Society Consensus class D lesions involving the native circulation. Technical success of the endovascular recanalization procedure was achieved in all but one limb (95%). The mean ankle brachial indices before and after treatment were 0.34 and 0.73, respectively. There were no major complications or emergency amputations. Mean patient follow-up was 64 weeks, and two patients were lost to follow-up. Primary patency rates at 3, 6, and 12 months were 87%, 48%, and 16%, respectively. Successful secondary procedures were performed in seven patients, with secondary patency rates at 3, 6, and 12 months of 88%, 73%, and 44%, respectively. Limb salvage rates at 12 and 24 months were 94% and 65%, and amputation-free survival rates at 12 and 24 months were 87% and 60%, respectively. Endovascular recanalization of native CTOs in patients with failed lower-extremity bypass grafts is technically feasible and safe and results in acceptable limb salvage. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  3. Effect of endovascular hypothermia on acute ischemic edema: morphometric analysis of the ICTuS trial.

    Science.gov (United States)

    Guluma, Kama Z; Oh, Haeryong; Yu, Sung-Wook; Meyer, Brett C; Rapp, Karen; Lyden, Patrick D

    2008-01-01

    Pilot studies of hypothermia for stroke suggest a potential benefit in humans. We sought to test whether hypothermia decreases post-ischemic edema using CT scans from a pilot trial of endovascular hypothermia for stroke. Eighteen patients with acute ischemic stroke underwent therapeutic hypothermia (target = 33 degrees C) for 12 or 24 h followed by a 12-h controlled re-warm using an endovascular system. CT scans obtained at baseline, 36-48 h (right after cooling and re-warming) and 30 days were digitized, intracranial compartment volumes measured using a validated stereological technique, and the calculated change in CSF volume between the three time-points were used as an estimate of edema formation in each patient. Patients were grouped retrospectively for analysis based on whether they cooled effectively (i.e., to a temperature nadir of less than 34.5 degrees C within 8 h) or not. Eleven patients were cooled partially or not at all, and seven were effectively cooled. Baseline demographics and compartment volumes and densities were similar in both groups. At 36-48 h, the total CSF volume had significantly decreased in the not-cooled group compared to the cooled group (P < 0.05), with no significant difference in mean volume of ischemia between them (73 +/- 73 ml vs. 54 +/- 59 ml, respectively), suggesting an ameliorative effect of hypothermia on acute edema formation. At 30 days, the difference in CSF volumes had resolved, and infarct volumes (73 +/- 71 ml vs. 84 +/- 102 ml, respectively) and functional outcomes were comparable. Endovascular hypothermia decreases acute post-ischemic cerebral edema. A larger trial is warranted to determine if it affects final infarct volume and outcome in stroke.

  4. CT perfusion-guided patient selection for endovascular recanalization in acute ischemic stroke: a multicenter study.

    Science.gov (United States)

    Turk, Aquilla S; Magarick, Jordan Asher; Frei, Don; Fargen, Kyle Michael; Chaudry, Imran; Holmstedt, Christine A; Nicholas, Joyce; Mocco, J; Turner, Raymond D; Huddle, Daniel; Loy, David; Bellon, Richard; Dooley, Gwendolyn; Adams, Robert; Whaley, Michelle; Fanale, Chris; Jauch, Edward

    2013-11-01

    The treatment of acute ischemic stroke is traditionally centered on time criteria, although recent evidence suggests that physiologic neuroimaging may be useful. In a multicenter study we evaluated the use of CT perfusion, regardless of time from symptom onset, in patients selected for intra-arterial treatment of ischemic stroke. Three medical centers retrospectively assessed stroke patients with a National Institute of Health Stroke Scale of ≥ 8, regardless of time from symptom onset. CT perfusion maps were qualitatively assessed. Patients with defined salvageable penumbra underwent intra-arterial revascularization of their occlusion. Functional outcome using the modified Rankin Score (mRS) was recorded. Two hundred and forty-seven patients were selected to undergo intra-arterial treatment based on CT perfusion imaging. The median time from symptom onset to procedure was 6 h. Patients were divided into two groups for analysis: ≤ 8 h and >8 h from symptom onset to endovascular procedure. We found no difference in functional outcome between the two groups (42.8% and 41.9% achieved 90-day mRS ≤ 2, respectively (p=1.0), and 54.9% vs 55.4% (p=1.0) achieved 90-day mRS ≤ 3, respectively). Overall, 48 patients (19.4%) had hemorrhages, of which 20 (8.0%) were symptomatic, with no difference between the groups (p=1.0). In a multicenter study, we demonstrated similar rates of good functional outcome and intracranial hemorrhage in patients with ischemic stroke when endovascular treatment was performed based on CT perfusion selection rather than time-guided selection. Our findings suggest that physiologic imaging-guided patient selection rather than time for endovascular reperfusion in ischemic stroke may be effective and safe.

  5. Endovascular treatment of acute arterial complications after living-donor liver transplantation

    International Nuclear Information System (INIS)

    Jeon, G.S.; Won, J.H.; Wang, H.J.; Kim, B.W.; Lee, B.M.

    2008-01-01

    Aim: The aim of this study was to evaluate the efficacy of endovascular treatment for acute arterial complications following living-donor liver transplantation (LDLT). Materials and methods: Of 79 LDLT patients, 17 (mean age 48 ± 8 years, range 33-66 years) who had acute arterial complications and underwent endovascular treatment were evaluated. Transcatheter arterial embolization was performed to control peritoneal bleeding. Catheter-directed thrombolysis using urokinase was performed in hepatic artery thromboses. The locations of complications and materials used were evaluated. The technical and clinical success rates were calculated. Results: Twenty-three acute arterial complications, including four hepatic artery thromboses and 19 cases of peritoneal haemorrhages were identified in 22 angiographic sessions in 17 patients. The mean duration between LDLT and first angiography was 3.2 ± 3.5 days (range 1-13 days). Hepatic artery recanalization with catheter-directed thrombolysis using urokinase was achieved in two patients. Transcatheter arterial embolization for peritoneal bleeding was successfully performed in 16 cases. The most common bleeding focus was the right inferior phrenic artery. Additional surgical management was needed in five patients to control bleeding or hepatic artery recanalization. Technical and clinical success rates of transcatheter arterial embolization were 84.2 and 63.1%, respectively. Overall technical success was achieved in 18 of 23 arterial complications (78.2%), and clinical success was achieved in 14 of 23 arterial complications (60.8%). Conclusion: Endovascular treatment for the acute arterial complications of haemorrhage or thrombosis in LDLT patients is safe and effective. Therefore, it should be considered as the first line of treatment in selective cases

  6. Tibioperoneal Occlusive Disease: A Review of below the Knee Endovascular Therapy in Patients with Critical Limb Ischemia.

    Science.gov (United States)

    Muir, Kathryn B; Cook, Patrick R; Sirkin, Maxwell R; Aidinian, Gilbert

    2017-01-01

    Tibioperoneal occlusive disease is one of the most difficult disease processes to successfully treat. Previous studies have attempted to address the outcomes of tibial interventions in this patient population; however, the majority of these study cohorts are composed of patients who have undergone concomitant aortoiliac or femoral procedures. Our objective was to present the outcomes of patients treated with endovascular intervention for isolated below-the-knee atherosclerotic disease causing critical limb ischemia (CLI). We performed a retrospective review of all patients who underwent isolated endovascular treatment of the below-knee popliteal, tibial, and/or peroneal arteries for CLI (Rutherford class 4-6). Primary outcomes include wound healing, reintervention rates, and amputation-free survival out to 5 years, as well as 1-year primary patency rates. 116 patients were identified as having undergone a tibial endovascular intervention. Ninety-two had concomitant aortoiliac or femoropopliteal interventions; after excluding those patients, we identified 24 limbs that were treated for isolated below-knee popliteal, tibial, and/or peroneal occlusive disease using an endovascular modality. 62.5% of limbs had successful wound healing, whereas 37.5% eventually required a major amputation. Mean time to amputation was 514.6 days (standard error: 57.3). Of those patients with successful limb salvage (n = 15), 66.7% required only the index procedure to heal; the remaining 33.3% required a repeat endovascular intervention, an arterial bypass, or a combination to successfully heal. The mean time to reintervention was 780.1 days (standard error: 179.5). The 1-year primary patency rate was 52.6% (n = 19). Patients with CLI secondary to isolated below-the-knee atherosclerotic occlusive disease are a difficult population to successfully treat; despite this, these patients benefit from an initial attempt at endovascular limb salvage. In our experience, this approach

  7. The importance of expert feedback during endovascular simulator training.

    LENUS (Irish Health Repository)

    Boyle, Emily

    2011-07-01

    Complex endovascular skills are difficult to obtain in the clinical environment. Virtual reality (VR) simulator training is a valuable addition to current training curricula, but is there a benefit in the absence of expert trainers?

  8. Clinical impact of chronic renal insufficiency on endovascular aneurysm repair.

    Science.gov (United States)

    Park, Brian; Mavanur, Arun; Drezner, A David; Gallagher, James; Menzoian, James O

    Endovascular aneurysm repair of abdominal aortic aneurysms has become a viable alternative to open repair. A significant proportion of this patient population has chronic renal insufficiency. The surgical outcomes associated with endovascular repair in 342 patients, with and without chronic renal insufficiency, are reported. Perioperative mortality, length of admission, length of intensive care unit admission, and rates of acute renal failure, congestive heart failure, myocardial infarction, conversion to open surgery, progression to hemodialysis, and incidence of endoleaks were retrospectively reviewed and analyzed. Endovascular repair demonstrated higher rates of acute renal failure, longer length of stay, and longer intensive care unit admissions in patients with chronic renal insufficiency. Patients with severe renal dysfunction demonstrated markedly elevated mortality and morbidity. These results indicate that chronic renal insufficiency is not an absolute contraindication to endovascular repair in patients with moderate renal dysfunction, but patients with severe renal dysfunction perform poorly after aortic reconstruction.

  9. Update on acute endovascular and surgical stroke treatment

    DEFF Research Database (Denmark)

    Kondziella, D; Cortsen, M; Eskesen, V

    2013-01-01

    Emergency stroke care has become a natural part of the emerging discipline of neurocritical care and demands close cooperation between the neurologist and neurointerventionists, neurosurgeons, and anesthesiologists. Endovascular treatment (EVT), including intra-arterial thrombolysis, mechanical...

  10. Extra-Thoracic Supra-aortic Bypass Surgery Is Safe in Thoracic Endovascular Aortic Repair and Arterial Occlusive Disease Treatment.

    Science.gov (United States)

    Gombert, Alexander; van Issum, Lea; Barbati, Mohammad E; Grommes, Jochen; Keszei, Andras; Kotelis, Drosos; Jalaie, Houman; Greiner, Andreas; Jacobs, Michael J; Kalder, Johannes

    2018-04-20

    The safety and feasibility of supra-aortic debranching as part of endovascular aortic surgery or as a treatment option for arterial occlusive disease (AOD) remains controversial. The aim of this study was to assess the clinical outcome of this surgery. This single centre, retrospective study included 107 patients (mean age 69.2 years, 38.4% women) who underwent supra-aortic bypass surgery (carotid-subclavian bypass, carotid-carotid bypass, and carotid-carotid-subclavian bypass) because of thoracic or thoraco-abdominal endovascular aortic repair (57%; 61/107) or as AOD treatment (42.9%; 46/107) between January 2006 and January 2015. Mortality, morbidity with a focus on neurological complications, and patency rate were assessed. Twenty-six of 107 (14.2%) of the debranching patients were treated under emergency conditions because of acute type B dissection or symptomatic aneurysm. Follow up, conducted by imaging interpretation and telephone interviews, continued till March 2017 (mean 42.1, 0-125, months). The in hospital mortality rate was 10.2% (11/107), all of these cases from the debranching group and related to emergency procedures (p supra-aortic bypass surgery involves low complication rates and high mid-term bypass patency rates. It is a safe and feasible treatment option in the form of debranching in combination with endovascular aortic aneurysm repair and in AOD. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  11. Embolization by micro navigation for treatment of persistent type 2 Endoleaks after endovascular abdominal aortic aneurysm repair

    Directory of Open Access Journals (Sweden)

    Bruno Lorenção de Almeida

    2014-12-01

    Full Text Available Background:Endovascular repair has become established as a safe and effective method for treatment of abdominal aortic aneurysms. One major complication of this treatment is leakage, or endoleaks, of which type 2 leaks are the most common.Objective:To conduct a brief review of the literature and evaluate the safety and effectiveness of embolization by micronavigation for treatment of type 2 endoleaks.Method:A review of medical records from patients who underwent endovascular repair of abdominal aortic aneurysms identified 5 patients with persistent type 2 endoleaks. These patients were submitted to embolization by micronavigation.Results:In all cases, angiographic success was achieved and control CT scans showed absence of type 2 leaks and aneurysm sacs that had reduced in size after the procedure.Conclusion:Treatment of type 2 endoleaks using embolization by micronavigation is an effective and safe method and should be considered as a treatment option for this complication after endovascular repair of abdominal aortic aneurysms.

  12. Endovascular Stenting of Peripheral Infected Aneurysms: A Temporary Measure or a Definitive Solution in High-Risk Patients

    International Nuclear Information System (INIS)

    Riga, Celia; Bicknell, Colin; Jindal, Ravul; Cheshire, Nicholas; Hamady, Mohamad

    2008-01-01

    The purpose of this study was to demonstrate the use of endovascular technology in the management of peripheral infected aneurysms in high-risk patients as a temporary measure or definitive solution. Five cases underwent successful endovascular stenting of infected aneurysms of the subclavian, femoral, and carotid arteries. All these patients were at high risk for open surgery. Covered stents were placed by percutaneous approach under local anesthesia in all patients. Postoperatively, antibiotics were continued for 3 months. A literature review using the Medline database was also undertaken, and all the relevant papers on endovascular management of peripheral infected aneurysms were taken into account. Stent deployment was successful in all patients. One patient died of mediastinal sepsis and another from type A aortic dissection 5 weeks later. Two patients required drainage of the infected hematoma. Three patients did well at a median follow-up of 1 year, with no evidence of sepsis. A review of the literature shows promising early and midterm results. Most early reports were of single cases, reflecting the low incidence of peripheral infected aneurysms. We conclude that further development of endoluminal techniques and long-term follow-up to establish the durability of stenting could potentially lead to a decrease in the high morbidity and mortality rates associated with infected aneurysmal disease in this high-risk group of patients.

  13. Possible role of an endovascular provocative test in the diagnosis of glossopharyngeal neuralgia as a vascular compression syndrome.

    Science.gov (United States)

    Matsushima, T; Goto, Y; Ishioka, H; Mihara, F; Fukui, M

    1999-01-01

    We utilized endovascular provocative techniques to identify the indications for microvascular decompression surgery in a serious case of glossopharyngeal neuralgia. This is the first reported case in which an endovascular provocative test was applied for diagnosis of glossopharyngeal neuralgia as a vascular compression syndrome. A 68-year-old woman presented with severe paroxysmal facial pain which could not be controlled by medical therapy. Partial effectiveness to carbamazepine led us to wonder whether or not the selection of microvascular decompression surgery would be appropriate. Pre-operative angiography was performed. During the examination a microcatheter was inserted into the right posterior inferior cerebellar artery (PICA), and an attack of typical glossopharyngeal neuralgia occurred. The patient thus underwent microvascular decompression surgery. The PICA was verified to compress the glossopharyngeal nerve and therefore was moved to induce decompression. The patient has since experienced no further pain for one year postoperatively. The diagnosis of glossopharyngeal neuralgia is sometimes complex and it is difficult to select the most appropriate surgical modality. In such cases this endovascular provocative technique may thus be useful for making a definitive decision or microvascular decompression surgery.

  14. Patterns in neurosurgical adverse events: endovascular neurosurgery.

    Science.gov (United States)

    Wong, Judith M; Ziewacz, John E; Panchmatia, Jaykar R; Bader, Angela M; Pandey, Aditya S; Thompson, B Gregory; Frerichs, Kai; Gawande, Atul A

    2012-11-01

    As part of a project to devise evidence-based safety interventions for specialty surgery, the authors sought to review current evidence in endovascular neurosurgery concerning the frequency of adverse events in practice, their patterns, and current methods of reducing the occurrence of these events. This review represents part of a series of papers written to consolidate information about these events and preventive measures as part of an ongoing effort to ascertain the utility of devising system-wide policies and safety tools to improve neurosurgical practice. Based on a review of the literature, thromboembolic events appeared to be the most common adverse events in endovascular neurosurgery, with a reported incidence ranging from 2% to 61% depending on aneurysm rupture status and mode of detection of the event. Intraprocedural and periprocedural prevention and rescue regimens are advocated to minimize this risk; however, evidence on the optimal use of anticoagulant and antithrombotic agents is limited. Furthermore, it is unknown what proportion of eligible patients receive any prophylactic treatment. Groin-site hematoma is the most common access-related complication. Data from the cardiac literature indicate an overall incidence of 9% to 32%, but data specific to neuroendovascular therapy are scant. Manual compression, compression adjuncts, and closure devices are used with varying rates of success, but no standardized protocols have been tested on a broad scale. Contrast-induced nephropathy is one of the more common causes of hospital-acquired renal insufficiency, with an incidence of 30% in high-risk patients after contrast administration. Evidence from medical fields supports the use of various preventive strategies. Intraprocedural vessel rupture is infrequent, with the reported incidence ranging from 1% to 9%, but it is potentially devastating. Improvements in device technology combined with proper endovascular technique play an important role in reducing

  15. Emergency endovascular repair of ruptured visceral artery aneurysms

    Directory of Open Access Journals (Sweden)

    Tang Tjun

    2007-07-01

    Full Text Available Abstract Background Visceral artery aneurysms although rare, have very high mortality if they rupture. Case presentation An interesting case of a bleeding inferior pancreaticduodenal artery aneurysm is reported in a young patient who presented with hypovolemic shock while being treated in the hospital after undergoing total knee replacement. Endovascular embolization was successfully employed to treat this patient, with early hospital discharge. Conclusion Prompt diagnosis and endovascular management of ruptured visceral aneuryms can decrease the associated mortality and morbidity.

  16. Current endovascular management of the ischaemic diabetic foot

    Science.gov (United States)

    Gerassimidis, T; Karkos, CD; Karamanos, D; Kamparoudis, A

    2008-01-01

    Ischaemic diabetic foot ulcers pose a significant problem which is associated with a high likelihood of amputation. With the advent of endovascular surgery, the management of lower limb arterial lesions in the diabetic population has become more appealing. Coronary 0.014 monorail guide wires, appropriate sized angioplasty balloons and stents, and subintimal recanalisation, are all useful adjuncts and techniques to achieve revascularization. This article reviews the modern endovascular management of the diabetic foot. PMID:18923656

  17. Current endovascular management of the ischaemic diabetic foot

    OpenAIRE

    Gerassimidis, T; Karkos, CD; Karamanos, D; Kamparoudis, A

    2008-01-01

    Ischaemic diabetic foot ulcers pose a significant problem which is associated with a high likelihood of amputation. With the advent of endovascular surgery, the management of lower limb arterial lesions in the diabetic population has become more appealing. Coronary 0.014 monorail guide wires, appropriate sized angioplasty balloons and stents, and subintimal recanalisation, are all useful adjuncts and techniques to achieve revascularization. This article reviews the modern endovascular mana...

  18. Complications in Endovascular Neurosurgery: Critical Analysis and Classification.

    Science.gov (United States)

    Ravindra, Vijay M; Mazur, Marcus D; Park, Min S; Kilburg, Craig; Moran, Christopher J; Hardman, Rulon L; Couldwell, William T; Taussky, Philipp

    2016-11-01

    Precisely defining complications, which are used to measure overall quality, is necessary for critical review of delivery of care and quality improvement in endovascular neurosurgery, which lacks common definitions for complications. Furthermore, in endovascular interventions, events that may be labeled complications may not always negatively affect outcome. Our objective is to provide precise definitions for quality evaluation within endovascular neurosurgery. Thus, we propose an endovascular-specific classification system of complications based on our own patient series. This single-center review included all patients who had endovascular interventions from September 2013 to August 2015. Complication types were analyzed, and a descriptive analysis was undertaken to calculate the incidence of complications overall and in each category. Two hundred and seventy-five endovascular interventions were performed in 245 patients (65% female; mean age, 55 years). Forty complications occurred in 39 patients (15%), most commonly during treatment of intracranial aneurysms (24/40). Mechanical complications (eg, device deployment, catheter, or closure device failure) occurred in 8/40, technical complications (eg, failure to deploy flow diverter, unintended embolization, air emboli, retroperitoneal hemorrhage, dissection) in 11/40, judgment errors (eg, patient or equipment selection) in 9/40, and critical events (eg, groin hematoma, hemorrhagic or thromboembolic complications) in 12/40 patients. Only 12/40 complications (30%) resulted in new neurologic deficits, vessel injury requiring surgery, or blood transfusion. We propose an endovascular-specific classification system of complications with 4 categories: mechanical, technical, judgment errors, and critical events. This system provides a framework for future studies and quality control in endovascular neurosurgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Endovascular Treatment for Pseudoaneurysms after Surgical Correction of Aortic Coarctation

    Directory of Open Access Journals (Sweden)

    M. Rabellino

    2011-01-01

    Full Text Available Late complications after surgical repair of aortic coarctation are not uncommon. Among these complications pseudoaneurysms are the most frequent complications, occurring between 3 and 38%. Reoperation in these patients is associated with high morbidity and mortality. In the last decade, endovascular techniques emerged as an alternative to conventional surgery with excellent results. We report the case of two patients who presented with pseudoaneurysms after surgical correction for aortic coarctation, which were treated by endovascular means.

  20. Endovascular Treatment of Late Thoracic Aortic Aneurysms after Surgical Repair of Congenital Aortic Coarctation in Childhood

    Science.gov (United States)

    Juszkat, Robert; Perek, Bartlomiej; Zabicki, Bartosz; Trojnarska, Olga; Jemielity, Marek; Staniszewski, Ryszard; Smoczyk, Wiesław; Pukacki, Fryderyk

    2013-01-01

    Background In some patients, local surgery-related complications are diagnosed many years after surgery for aortic coarctation. The purposes of this study were: (1) to systematically evaluate asymptomatic adults after Dacron patch repair in childhood, (2) to estimate the formation rate of secondary thoracic aortic aneurysms (TAAs) and (3) to assess outcomes after intravascular treatment for TAAs. Methods This study involved 37 asymptomatic patients (26 female and 11 male) who underwent surgical repair of aortic coarctation in the childhood. After they had reached adolescence, patients with secondary TAAs were referred to endovascular repair. Results Follow-up studies revealed TAA in seven cases (19%) (including six with the gothic type of the aortic arch) and mild recoarctation in other six (16%). Six of the TAA patients were treated with stentgrafts, but one refused to undergo an endovascular procedure. In three cases, stengrafts covered the left subclavian artery (LSA), in another the graft was implanted distally to the LSA. In two individuals, elective hybrid procedures were performed with surgical bypass to the supraaortic arteries followed by stengraft implantation. All subjects survived the secondary procedures. One patient developed type Ia endoleak after stentgraft implantation that was eventually treated with a debranching procedure. Conclusions The long-term course of clinically asymptomatic patients after coarctation patch repair is not uncommonly complicated by formation of TAAs (particularly in individuals with the gothic pattern of the aortic arch) that can be treated effectively with stentgrafts. However, in some patients hybrid procedures may be necessary. PMID:24386233

  1. The Effect of Endovascular Revascularization of Common Iliac Artery Occlusions on Erectile Function

    Energy Technology Data Exchange (ETDEWEB)

    Gur, Serkan, E-mail: mserkangur@yahoo.com [Sifa Hospital, Department of Radiology (Turkey); Ozkan, Ugur [Baskent University, Department of Radiology, Faculty of Medicine (Turkey); Onder, Hakan; Tekbas, Gueven [Dicle University, Department of Radiology, Faculty of Medicine (Turkey); Oguzkurt, Levent [Baskent University, Department of Radiology, Faculty of Medicine (Turkey)

    2013-02-15

    To determine the incidence of erectile dysfunction in patients with common iliac artery (CIA) occlusive disease and the effect of revascularization on erectile function using the sexual health inventory for males (SHIM) questionnaire. All patients (35 men; mean age 57 {+-} 5 years; range 42-67 years) were asked to recall their sexual function before and 1 month after iliac recanalization. Univariate and multivariate analyses were performed to determine variables effecting improvement of impotence. The incidence of impotence in patients with CIA occlusion was 74% (26 of 35) preoperatively. Overall 16 (46%) of 35 patients reported improved erectile function after iliac recanalization. The rate of improvement of impotence was 61.5% (16 of 26 impotent patients). Sixteen patients (46%), including seven with normal erectile function before the procedure, had no change. Three patients (8%) reported deterioration of their sexual function, two of whom (6%) had normal erectile function before the procedure. The median SHIM score increased from 14 (range 4-25) before the procedure to 20 (range 1-25) after the procedure (P = 0.005). The type of recanalization, the age of the patients, and the length of occlusion were related to erectile function improvement in univariate analysis. However, these factors were not independent factors for improvement of erectile dysfunction in multivariate analysis (P > 0.05). Endovascular recanalization of CIA occlusions clearly improves sexual function. More than half of the patients with erectile dysfunction who underwent endovascular recanalization of the CIA experienced improvement.

  2. The Effect of Endovascular Revascularization of Common Iliac Artery Occlusions on Erectile Function

    International Nuclear Information System (INIS)

    Gur, Serkan; Ozkan, Uğur; Onder, Hakan; Tekbas, Güven; Oguzkurt, Levent

    2013-01-01

    To determine the incidence of erectile dysfunction in patients with common iliac artery (CIA) occlusive disease and the effect of revascularization on erectile function using the sexual health inventory for males (SHIM) questionnaire. All patients (35 men; mean age 57 ± 5 years; range 42–67 years) were asked to recall their sexual function before and 1 month after iliac recanalization. Univariate and multivariate analyses were performed to determine variables effecting improvement of impotence. The incidence of impotence in patients with CIA occlusion was 74% (26 of 35) preoperatively. Overall 16 (46%) of 35 patients reported improved erectile function after iliac recanalization. The rate of improvement of impotence was 61.5% (16 of 26 impotent patients). Sixteen patients (46%), including seven with normal erectile function before the procedure, had no change. Three patients (8%) reported deterioration of their sexual function, two of whom (6%) had normal erectile function before the procedure. The median SHIM score increased from 14 (range 4–25) before the procedure to 20 (range 1–25) after the procedure (P = 0.005). The type of recanalization, the age of the patients, and the length of occlusion were related to erectile function improvement in univariate analysis. However, these factors were not independent factors for improvement of erectile dysfunction in multivariate analysis (P > 0.05). Endovascular recanalization of CIA occlusions clearly improves sexual function. More than half of the patients with erectile dysfunction who underwent endovascular recanalization of the CIA experienced improvement.

  3. Establishment of mesenteric venous thrombosis in a porcine model using a transhepatic endovascular approach.

    Science.gov (United States)

    Kai, Liu; Jiaxiang, Meng; Xinxin, Fan; Baochen, Liu; Weiwei, Ding; Xingjiang, Wu; Shuofei, Yang; Jieshou, Li

    2015-12-01

    By using endovascular techniques, we set up an animal model of mesenteric venous thrombosis to avoid surgical laparotomy. Ten pigs underwent percutaneous transhepatic puncture to create animal model of acute superior mesenteric venous thrombosis. Experimental animals were injected with thrombin via indwelling catheter, while sham-operated animals with receiving physiological saline instead of thrombin. Animals were divided into three groups according to the time of thrombosis: the control (n=3, sham group), group A (n=3, 24h follow up) and group B (n=4, 72 h follow up). Blood samples were collected and tested at the baseline and end of the experiment from the systemic circulation (jugular vein). A pathologist, blinded to the performed interventions, graded the ischemic lesions. Nine pigs were successfully conducted MVT model, while one died of liver rupture during the experiment. White blood cell (WBC) count (group A: 18.77 ± 1.29, group B: 28.93 ± 3.13), D-dimer (group A: 8.30 ± 1.93, group B: 17.30 ± 2.48) and lactate dehydrogenase (LDH) (group A: 452.13 ± 53.14, group B: 753.97 ± 65.29) showed a rapid step-up between the experimental animals and control animals (Pmesenteric ischemia by statistical analysis (Pmesenteric venous thrombosis was feasible. Moreover, further animal studies are underway to evaluate the effectiveness and reproducibility of endovascular technique for MVT model. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  4. Endovascular treatment of late thoracic aortic aneurysms after surgical repair of congenital aortic coarctation in childhood.

    Directory of Open Access Journals (Sweden)

    Robert Juszkat

    Full Text Available BACKGROUND: In some patients, local surgery-related complications are diagnosed many years after surgery for aortic coarctation. The purposes of this study were: (1 to systematically evaluate asymptomatic adults after Dacron patch repair in childhood, (2 to estimate the formation rate of secondary thoracic aortic aneurysms (TAAs and (3 to assess outcomes after intravascular treatment for TAAs. METHODS: This study involved 37 asymptomatic patients (26 female and 11 male who underwent surgical repair of aortic coarctation in the childhood. After they had reached adolescence, patients with secondary TAAs were referred to endovascular repair. RESULTS: Follow-up studies revealed TAA in seven cases (19% (including six with the gothic type of the aortic arch and mild recoarctation in other six (16%. Six of the TAA patients were treated with stentgrafts, but one refused to undergo an endovascular procedure. In three cases, stengrafts covered the left subclavian artery (LSA, in another the graft was implanted distally to the LSA. In two individuals, elective hybrid procedures were performed with surgical bypass to the supraaortic arteries followed by stengraft implantation. All subjects survived the secondary procedures. One patient developed type Ia endoleak after stentgraft implantation that was eventually treated with a debranching procedure. CONCLUSIONS: The long-term course of clinically asymptomatic patients after coarctation patch repair is not uncommonly complicated by formation of TAAs (particularly in individuals with the gothic pattern of the aortic arch that can be treated effectively with stentgrafts. However, in some patients hybrid procedures may be necessary.

  5. Comparative Efficacy of Endovascular Revascularization Versus Supervised Exercise Training in Patients With Intermittent Claudication: Meta-Analysis of Randomized Controlled Trials.

    Science.gov (United States)

    Pandey, Ambarish; Banerjee, Subhash; Ngo, Christian; Mody, Purav; Marso, Steven P; Brilakis, Emmanouil S; Armstrong, Ehrin J; Giri, Jay; Bonaca, Marc P; Pradhan, Aruna; Bavry, Anthony A; Kumbhani, Dharam J

    2017-04-10

    The authors performed a meta-analysis of randomized controlled trials to compare the efficacy of initial endovascular treatment with or without supervised exercise training (SET) versus SET alone in patients with intermittent claudication. Current guidelines recommend SET as the initial treatment modality for patients with intermittent claudication, in addition to optimal medical therapy. The role of endovascular therapy as primary treatment for claudication has been controversial. The primary outcome was treadmill-measured maximal walk distance at the end of follow-up. Secondary outcomes included resting ankle brachial index (ABI) and treadmill-measured ischemic claudication distance on follow-up. Risk of revascularization or amputations was also compared. Pooled estimates of the difference in outcomes between endovascular therapy with or without SET and SET-only groups were calculated using fixed and random effects models. A total of 987 patients from 7 trials were included. In pooled analysis, compared with SET only (reference group), patients that underwent combined endovascular therapy and SET had significantly higher maximum walk distance (standardized mean difference 0.79 [95% confidence interval (CI): 0.18 to 1.39]; weighted mean difference 98.9 [95% CI: 31.4 to 166.4 feet], and lower risk of revascularization or amputation (odds ratio 0.19 [95% CI: (0.09 to 0.40]; p < 0.0001, number needed to treat = 8) over a median follow-up of 12.4 months. By contrast, revascularization was not associated with significant improvement in exercise capacity or risk of future revascularization or amputation, compared with SET alone. Follow-up ABI was significantly higher among patients that underwent endovascular therapy with or without SET as compared with SET alone. Compared with initial SET only, endovascular therapy in combination with SET is associated with significant improvement in total walking distance, ABI, and risk of future revascularization or amputation. By

  6. Endovascular management of delayed post-pancreatectomy haemorrhage

    International Nuclear Information System (INIS)

    Pottier, Edwige; Ronot, Maxime; Vilgrain, Valerie; Gaujoux, Sebastien; Cesaretti, Manuela; Barbier, Louise; Sauvanet, Alain

    2016-01-01

    To assess the patient outcome after endovascular treatment of delayed post-pancreatectomy haemorrhage (PPH) as first-line treatment. Between January 2005 and November 2013, all consecutive patients referred for endovascular treatment of PPH were included. Active bleeding, pseudoaneurysms, collections and the involved artery were recorded on pretreatment CT. Endovascular procedures were classified as technical success (source of bleeding identified on angiogram and treated), technical failure (source of bleeding identified but incompletely treated) and abstention (no abnormality identified, no treatment performed). Factors associated with rebleeding were analysed. Sixty-nine patients (53 men) were included (mean 59 years old (32-75)). Pretreatment CT showed 27 (39 %) active bleeding. In 22 (32 %) cases, no involved artery was identified. Technical success, failure and abstention were observed in 48 (70 %), 9 (13 %) and 12 patients (17 %), respectively. Thirty patients (43 %) experienced rebleeding. Rebleeding rates were 29 %, 58 % and 100 % in case of success, abstention and failure (p < 0.001). Treatment failure/abstention was the only factor associated with rebleeding. Overall, 74 % of the patients were successfully treated by endovascular procedure(s) alone. After a first endovascular procedure for PPH, the rebleeding rate is high and depends upon the success of the procedure. Most patients are successfully treated by endovascular approach(es) alone. (orig.)

  7. Endovascular management of delayed post-pancreatectomy haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Pottier, Edwige [Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Department of Radiology, Clichy, Hauts-de-Seine (France); Ronot, Maxime; Vilgrain, Valerie [Beaujon Hospital, University Hospitals Paris Nord Val de Seine, Department of Radiology, Clichy, Hauts-de-Seine (France); University Paris Diderot, Paris (France); INSERM U1149, centre de recherche biomedicale Bichat-Beaujon, CRB3, Paris (France); Gaujoux, Sebastien; Cesaretti, Manuela; Barbier, Louise [APHP, University Hospitals Paris Nord Val de Seine, Beaujon, Department of Surgery, Clichy, Hauts-de-Seine (France); Sauvanet, Alain [University Paris Diderot, Paris (France); APHP, University Hospitals Paris Nord Val de Seine, Beaujon, Department of Surgery, Clichy, Hauts-de-Seine (France)

    2016-10-15

    To assess the patient outcome after endovascular treatment of delayed post-pancreatectomy haemorrhage (PPH) as first-line treatment. Between January 2005 and November 2013, all consecutive patients referred for endovascular treatment of PPH were included. Active bleeding, pseudoaneurysms, collections and the involved artery were recorded on pretreatment CT. Endovascular procedures were classified as technical success (source of bleeding identified on angiogram and treated), technical failure (source of bleeding identified but incompletely treated) and abstention (no abnormality identified, no treatment performed). Factors associated with rebleeding were analysed. Sixty-nine patients (53 men) were included (mean 59 years old (32-75)). Pretreatment CT showed 27 (39 %) active bleeding. In 22 (32 %) cases, no involved artery was identified. Technical success, failure and abstention were observed in 48 (70 %), 9 (13 %) and 12 patients (17 %), respectively. Thirty patients (43 %) experienced rebleeding. Rebleeding rates were 29 %, 58 % and 100 % in case of success, abstention and failure (p < 0.001). Treatment failure/abstention was the only factor associated with rebleeding. Overall, 74 % of the patients were successfully treated by endovascular procedure(s) alone. After a first endovascular procedure for PPH, the rebleeding rate is high and depends upon the success of the procedure. Most patients are successfully treated by endovascular approach(es) alone. (orig.)

  8. Endovascular Treatment of an Aortoiliac Tuberculous Pseudoaneurysm

    International Nuclear Information System (INIS)

    Villegas, Miguel O.; Mereles, Alberto Pérez; Tamashiro, Gustavo A.; Dini, Andrés E.; Mollón, Ana P.; De Cándido, Laura V.; Zelaya, Denis A.; Soledispa-Suarez, Carlos I.; Denato, Sergio; Tamashiro, Alberto; Diaz, Jose A.

    2013-01-01

    We report a rare case of a tuberculous mycotic aortoiliac pseudoaneurysm treated with an endovascular procedure and follow-up of 36 months. The patient was a white 72-year-old man with pulmonary tuberculosis and a former smoker with hypertension, chronic renal failure, and dyslipidemia. A computed tomographic scan of the abdomen and pelvis revealed a left paravertebral cavity with fluid content and involvement of vertebrae L2–L4. After a surgical repair attempt, the patient was treated with the implant of a bifurcated endoprosthesis. Because it is unlikely that any center has extensive experience in the management of this rare manifestation of the disease, we reviewed the literature for similar cases.

  9. Endovascular therapy for acute stroke: Quo vadis?

    Directory of Open Access Journals (Sweden)

    Venkatesh S Madhugiri

    2013-01-01

    Full Text Available Endovascular therapy (EVT has gained vogue in the management of patients with acute stroke. Newer stent-retriever devices have led to better recanalization rates. In many centers, EVT is slowly being used as an add on to or in some instances, even as an alternative to intravenous tissue plasminogen activator (IV tPA. The publication of the results of the SYNTHESIS expansion, Interventional Management of Stroke III and Mechanical Retrieval Recanalization of Stroke Clots Using Embolectomy trials in 2013 has questioned the enthusiastic use of EVT in acute stroke. They demonstrate that EVT (using a variety of devices is no superior to IV tPA in the management of acute stroke. In the light of these controversial findings, we review the current status of EVT in the management of acute stroke.

  10. Endovascular Treatment of an Aortoiliac Tuberculous Pseudoaneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Villegas, Miguel O.; Mereles, Alberto Perez; Tamashiro, Gustavo A.; Dini, Andres E.; Mollon, Ana P.; De Candido, Laura V.; Zelaya, Denis A.; Soledispa-Suarez, Carlos I.; Denato, Sergio; Tamashiro, Alberto; Diaz, Jose A., E-mail: joseantoniodiaz@hotmail.com [Hospital Nacional Prof. Alejandro Posadas, Department of Cardiology, Section of Hemodinamia (Argentina)

    2013-04-15

    We report a rare case of a tuberculous mycotic aortoiliac pseudoaneurysm treated with an endovascular procedure and follow-up of 36 months. The patient was a white 72-year-old man with pulmonary tuberculosis and a former smoker with hypertension, chronic renal failure, and dyslipidemia. A computed tomographic scan of the abdomen and pelvis revealed a left paravertebral cavity with fluid content and involvement of vertebrae L2-L4. After a surgical repair attempt, the patient was treated with the implant of a bifurcated endoprosthesis. Because it is unlikely that any center has extensive experience in the management of this rare manifestation of the disease, we reviewed the literature for similar cases.

  11. Endovascular approach and technique for treatment of transverse-sigmoid dural arteriovenous fistula with cortical reflux: the importance of venous sinus sacrifice.

    Science.gov (United States)

    Carlson, Andrew Phillip; Alaraj, Ali; Amin-Hanjani, Sepideh; Charbel, Fady T; Aletich, Victor

    2013-11-01

    Treatment of dural arteriovenous fistula involving the transverse-sigmoid region with cortical reflux is complex and treatment options may require sacrifice of the fistulous segment of the sinus. To review our results in this subset of patients and describe current endovascular decision-making and approaches. We reviewed cases of endovascular sinus sacrifice for dural fistulas at our institution from 2007 to 2012. Demographic, decision-making, technical and outcome data were collected. Seven patients were identified who underwent endovascular sinus sacrifice for treatment of dural fistula during this 4-year period. Determination of the fistulous sinus segment was based on the pattern of cortical drainage. Endovascular access to the sinus was achieved by transarterial, transvenous or via open surgery in one case. Complete cure of the target fistula was obtained in all cases. One patient had transient post-procedure headache. There were no hemorrhages, new neurological deficits or signs of increased intracranial pressure. Six of the seven patients had angiographic follow-up at least 6 months after treatment with no recurrence. Fistulas of the transverse-sigmoid sinuses with cortical reflux may require sacrifice of the parent sinus for cure. Defining the fistulous segment and occluding this segment deliberately, completely and precisely is essential for cure. Several modalities and approaches can be used to achieve this. For properly selected patients, cure of the lesions can be achieved with this method with low risk of morbidity.

  12. Developing cross-specialty endovascular simulation training.

    Science.gov (United States)

    Nelson, Katharine; Bagnall, Alan; Nesbitt, Craig; Davey, Philip; Mafeld, Sebastian

    2014-10-01

    Simulation is increasingly recognised as a valuable tool in training tomorrow's doctors. This technology has the potential to improve patient safety and address some of the challenges posed by recent changes in doctors' training, yet the uptake has been slow in the majority of institutions. In our own centre, we noted existing equipment was used infrequently. We sought to address this problem through the development of a 1-day training course in simulation (SIM) and basic interventional skills aimed at trainees from across different endovascular specialties. A 1-day course for trainees in cardiology, interventional radiology and vascular surgery was piloted. A variety of endovascular simulators were used to teach core skills common to all three specialties, under the umbrella theme of safe access, safe navigation and safe closure. Independent continuing use of SIM-based training was encouraged. Trainee and faculty member experiences of SIM training in a cross-specialty environment were explored by interview and online questionnaire. Thirty-six trainees completed the pilot training course. Feedback was almost universally positive, with all trainees agreeing that SIM was useful in achieving the course's objectives, and that they would recommend the course to a colleague. Cross-specialty training was viewed positively by trainees and trainers alike, with benefits identified in knowledge and skills sharing, as well as fostering better clinical collaboration. SIM-based training was perceived as useful in promoting patient safety, and is considered to be a desirable component of future training. We present a SIM-based model that achieves economies of scale by delivering common skill-set training for doctors from different specialties. Through our experiences piloting this course we discuss how the recognised barriers to adopting this new technology may be addressed and offer insights into how SIM may be integrated into existing training programmes. © 2014 John Wiley

  13. Anesthesia Approach in Endovascular Aortic Reconstruction

    Directory of Open Access Journals (Sweden)

    Ayşin Alagöl

    2013-03-01

    Full Text Available Introduction: We have analyzed our initial results of our anesthesia techniques in our new-onset endovascular aortic reconstruction cases.Patients and Methods: The perioperative data of 15 elective and emergent endovascular aortic reconstruction cases that were operated in 2010-2011 were collected in a database. The choice of anesthesia was made by the risk factors, surgical team’s preferences, type and location of the aortic pathology and by the predicted operation duration. The data of local and general anesthesia cases were compared.Results: Thirteen (86.7% cases were male and 2 (13.3% female. Eleven patients were in ASA Class III. The demographic parameters, ASA classifications, concurrent diseases were similar in both groups. Thirteen (86.7% cases had infrarenal abdominal aortic aneurysm and 2 (13.3% had Type III aortic dissection. The diastolic arterial pressures were lower in general anesthesia group in 20th and 40th minutes’ measurements just like the mean arterial pressure measurements at the 40th, 100th minutes and during the deployment of the graft. Postoperative mortality occurred in 3 (20.0% patients and they all had general anesthesia and they were operated on emergency basis. Postoperative morbidity occurred in four patients that had general anesthesia (acute renal failure, multi-organ failure and pneumonia. The other patient had atrial fibrillation on the 1st postoperative day and was converted to sinus rhythm with amiodarone infusion.Conclusion: Edovascular aortic reconstruction procedures can safely be performed with both general and local anesthesia less invasively compared to open surgery. General anesthesia may be preferred for the better hemodynamic control.

  14. Management of stenosis lesions during the period of endovascular treatment for acute ischemic stroke

    Directory of Open Access Journals (Sweden)

    Hong-xing HAN

    2017-11-01

    Full Text Available Objective To investigate the management of stenosis lesions during endovascular treatment for acute ischemic stroke. Methods A total of 36 acute ischemic stroke patients combined with intracranial/extracranial arterial stenosis were treated with endovascular treatment or bridging treatment. Time from aggravation on admission or in hospital stay to femoral artery puncture, from femoral arterypuncture to recanalization were recorded. Modified Thrombolysis in Cerebral Infarction (mTICI was usedto assess the recanalization immediately after operation. Modified Rankin Scale (mRS was used to evaluate prognosis at 90 d after operation. Occurrence rate of symptomatic intracranial hemorrhage and mortality were recorded. Results Among 36 patients, 13 patients (36.11% underwent intravenous thrombolysis and then endovascular thrombectomy. In all patients, there were 21 (58.33% with intracranial stenosis and 15 (41.67% with extracranial stenosis, 16 (44.44% with anterior circulation stenosis and 20 (55.56% with posterior circulation stenosis. Stent thrombectomy was used in 25 patients (69.44% , while balloon dilatation and/or stent implantation was used in 11 patients (30.56% . For 21 patients with intracranial arterial stenosis, 4 were treated with balloon dilatation only, 9 with Wingspan self-expandable stents and 8 with Apollo balloon-expandable stents. Fifteen patients with extracranial arterial stenosis were treated with balloon dilatation and stent implantation. A total of 33 patients (91.67% achieved recanalization (mTICI 2b-3 grade, 21 patients (58.33% had good outcomes (mRS ≤ 2 score, while symptomatic intracranial hemorrhage occurred in 2 patients (5.56% and 5 (13.89% died. There were no statistically significant differences in the rate of good prognosis, symptomatic intracranial hemorrhage and mortality between intracranial and extracranial arterial stenosis, anterior and posterior circulation stenosis (Fisher exact probability: P > 0.05, for

  15. Fatal late multiple emboli after endovascular treatment of abdominal aortic aneurysm. Case report

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Sandermann, Jes; Bruun-Petersen, J

    1998-01-01

    The short term experience of endovascular treatment of abdominal aortic aneurysms (AAA) seems promising but long term randomised data are lacking. Consequently, cases treated by endovascular procedures need to be closely followed for potential risks and benefits....

  16. Capturing the essence of developing endovascular expertise for the construction of a global assessment instrument

    DEFF Research Database (Denmark)

    Bech, Bo; Lönn, L; Schroeder, T V

    2010-01-01

    To explore what characterises the development of endovascular expertise and to construct a novel global assessment instrument.......To explore what characterises the development of endovascular expertise and to construct a novel global assessment instrument....

  17. Endovascular Mechanical Thromboaspiration of Right Hepatic Arterial Thrombosis After Liver Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Gandini, Roberto; Konda, Daniel [University of Rome “Tor Vergata”, Department of Diagnostic Imaging, Molecular Imaging, Interventional Radiology and Radiotherapy, PTV Foundation, “Tor Vergata” Hospital (Italy); Toti, Luca [University of Rome “Tor Vergata”, Department of Surgery, Section of Transplantation, PTV Foundation, “Tor Vergata” Hospital (Italy); Abrignani, Sergio, E-mail: stem83@gmail.com; Merolla, Stefano [University of Rome “Tor Vergata”, Department of Diagnostic Imaging, Molecular Imaging, Interventional Radiology and Radiotherapy, PTV Foundation, “Tor Vergata” Hospital (Italy); Tisone, Giuseppe [University of Rome “Tor Vergata”, Department of Surgery, Section of Transplantation, PTV Foundation, “Tor Vergata” Hospital (Italy); Floris, Roberto [University of Rome “Tor Vergata”, Department of Diagnostic Imaging, Molecular Imaging, Interventional Radiology and Radiotherapy, PTV Foundation, “Tor Vergata” Hospital (Italy)

    2017-04-15

    A 56-year-old male Patient presented 27 days after a liver transplantation (LT) with fever and hyperbilirubinemia. He underwent CT examination resulting in a diagnosis of right hepatic artery (HA) occlusion with hepatic bilomas. Once placed a long right femoral 6F introducer at the origin of the HA, a 0.014” guidewire was advanced over the thrombus, in a segmental branch. A 4MAX (Penumbra, Alameda, USA) catheter was advanced and withdrawn under constant aspiration until complete clot removal was achieved. Follow-up CT and D-US assessments at 12 months demonstrated regular HA patency and bilomas reduction. Endovascular thromboaspiration is an effective strategy in cases of E-HAT after LT.

  18. Endovascular Mechanical Thromboaspiration of Right Hepatic Arterial Thrombosis After Liver Transplantation

    International Nuclear Information System (INIS)

    Gandini, Roberto; Konda, Daniel; Toti, Luca; Abrignani, Sergio; Merolla, Stefano; Tisone, Giuseppe; Floris, Roberto

    2017-01-01

    A 56-year-old male Patient presented 27 days after a liver transplantation (LT) with fever and hyperbilirubinemia. He underwent CT examination resulting in a diagnosis of right hepatic artery (HA) occlusion with hepatic bilomas. Once placed a long right femoral 6F introducer at the origin of the HA, a 0.014” guidewire was advanced over the thrombus, in a segmental branch. A 4MAX (Penumbra, Alameda, USA) catheter was advanced and withdrawn under constant aspiration until complete clot removal was achieved. Follow-up CT and D-US assessments at 12 months demonstrated regular HA patency and bilomas reduction. Endovascular thromboaspiration is an effective strategy in cases of E-HAT after LT.

  19. Endovascular treatment of incoercible epistaxis and epidural cerebral hematoma. A case report.

    Science.gov (United States)

    Bortoluzzi, M; Pavia, M

    2006-09-15

    A young patient with a facial trauma after a road accident was admitted to our department with incoercible epistaxis. A CT scan showed a right pterional acute epidural hematoma (EDH). Angiography demonstrated multiple sources of bleeding of the right sphenopalatine arteries, cause of the epistaxis, and an intracranial leakage of the right middle meningeal artery, responsible for the EDH. The patient immediately underwent embolization of the right internal maxillary artery and right middle meningeal artery. The procedure stopped the epistaxis and no further enlargement of the EDH was observed, avoiding its surgical treatment. Endovascular surgery may be an effective procedure to stop the arterial meningeal bleeding sustaining acute EDH and may be a useful tool in the management of special cases of post traumatic EDH.

  20. Endovascular Radiofrequency Ablation for Varicose Veins

    Science.gov (United States)

    2011-01-01

    Executive Summary Objective The objective of the MAS evidence review was to conduct a systematic review of the available evidence on the safety, effectiveness, durability and cost–effectiveness of endovascular radiofrequency ablation (RFA) for the treatment of primary symptomatic varicose veins. Background The Ontario Health Technology Advisory Committee (OHTAC) met on August 26th, 2010 to review the safety, effectiveness, durability, and cost-effectiveness of RFA for the treatment of primary symptomatic varicose veins based on an evidence-based review by the Medical Advisory Secretariat (MAS). Clinical Condition Varicose veins (VV) are tortuous, twisted, or elongated veins. This can be due to existing (inherited) valve dysfunction or decreased vein elasticity (primary venous reflux) or valve damage from prior thrombotic events (secondary venous reflux). The end result is pooling of blood in the veins, increased venous pressure and subsequent vein enlargement. As a result of high venous pressure, branch vessels balloon out leading to varicosities (varicose veins). Symptoms typically affect the lower extremities and include (but are not limited to): aching, swelling, throbbing, night cramps, restless legs, leg fatigue, itching and burning. Left untreated, venous reflux tends to be progressive, often leading to chronic venous insufficiency (CVI). A number of complications are associated with untreated venous reflux: including superficial thrombophlebitis as well as variceal rupture and haemorrhage. CVI often results in chronic skin changes referred to as stasis dermatitis. Stasis dermatitis is comprised of a spectrum of cutaneous abnormalities including edema, hyperpigmentation, eczema, lipodermatosclerosis and stasis ulceration. Ulceration represents the disease end point for severe CVI. CVI is associated with a reduced quality of life particularly in relation to pain, physical function and mobility. In severe cases, VV with ulcers, QOL has been rated to be as bad

  1. Combined Endovascular and Microsurgical Management of Complex Cerebral Aneurysms

    Directory of Open Access Journals (Sweden)

    Omar eChoudhri

    2013-08-01

    Full Text Available Cerebral aneurysms are associated with a 50% mortality rate after rupture and patients can suffer significant morbidity during subsequent treatment. Neurosurgical management of both ruptured and unruptured aneurysms has evolved over the years. The historical practice of using microsurgical clipping to treat aneurysms has benefitted in the last two decades from tremendous improvement in endovascular technology. Microsurgery and endovascular therapies are often viewed as competing treatments but it is important to recognize their individual limitations. Some aneurysms are considered complex, due to several factors such as aneurysm anatomy and a patient’s clinical condition. A complex aneurysm often cannot be completely excluded with a single approach and its successful treatment requires a combination of microsurgical and endovascular techniques. Planning such an approach relies on understanding aneurysm anatomy and thus should routinely include 3D angiographic imaging. In patients with ruptured aneurysms, endovascular coiling is a well-tolerated early treatment and residual aneurysms can be treated with intervals of definitive clipping. Microsurgical clipping also can be used to reconstruct the neck of a complex aneurysm, allowing successful placement of coils across a narrow neck. Endovascular techniques are assisted by balloons, which can be used in coiling and testing parent vessel occlusion before sacrifice. In some cases microsurgical bypasses can provide alternate flow for planned vessel sacrifice. We present current paradigms for combining endovascular and microsurgical approaches to treat complex aneurysms and share our experience in 67 such cases. A dual microsurgical–endovascular approach addresses the challenge of intracranial aneurysms. This combination can be performed safely and produces excellent rates of aneurysm obliteration. Hybrid angiographic operating-room suites can foster seamless and efficient complementary application

  2. Fatal late multiple emboli after endovascular treatment of abdominal aortic aneurysm. Case report

    DEFF Research Database (Denmark)

    Lindholt, Jes Sanddal; Sandermann, Jes; Bruun-Petersen, J

    1998-01-01

    The short term experience of endovascular treatment of abdominal aortic aneurysms (AAA) seems promising but long term randomised data are lacking. Consequently, cases treated by endovascular procedures need to be closely followed for potential risks and benefits.......The short term experience of endovascular treatment of abdominal aortic aneurysms (AAA) seems promising but long term randomised data are lacking. Consequently, cases treated by endovascular procedures need to be closely followed for potential risks and benefits....

  3. Acute endovascular recanalization: lessons from randomized controlled trials.

    Science.gov (United States)

    Bendszus, Martin; Hacke, Werner

    2016-02-01

    The purpose is to review the results and impact of recent positive studies on endovascular stroke treatment in the context of previous negative trials. Since October 2014, the results of five randomized controlled multicenter trials on the endovascular stroke treatment as adjunct to conservative treatment (largely including intravenous tissue-type plasminogen activator) versus conservative treatment alone have been published. All of these trials largely used stent retrievers as endovascular device and included patients with proven large vessel occlusion (mostly distal internal carotid or proximal middle cerebral artery (M1), short time windows after stroke onset and mostly small infarctions on initial imaging. Over all there was an overwhelming beneficial effect on outcome measured as shift in the modified Rankin Scale score and independent survival, respectively. Moreover, the rate of adverse events, in particular hemorrhage rate, was not increased. These new findings contrast previous studies on endovascular stroke treatment using mostly first generation nonstent retriever devices, longer time windows and different imaging inclusion criteria, which were overall neutral for patient outcome. Endovascular stroke treatment with stent retrievers is the standard of care in large vessel occlusion. New randomized controlled trials should investigate safety and efficacy in extended indications as advanced time windows or more extensive signs of ischemia on initial imaging. The same applies for new devices apart from stent retrievers.

  4. Contemporary management of carotid blowout syndrome utilizing endovascular techniques.

    Science.gov (United States)

    Manzoor, Nauman F; Rezaee, Rod P; Ray, Abhishek; Wick, Cameron C; Blackham, Kristine; Stepnick, David; Lavertu, Pierre; Zender, Chad A

    2017-02-01

    To illustrate complex interdisciplinary decision making and the utility of modern endovascular techniques in the management of patients with carotid blowout syndrome (CBS). Retrospective chart review. Patients treated with endovascular strategies and/or surgical modalities were included. Control of hemorrhage, neurological, and survival outcomes were studied. Between 2004 and 2014, 33 patients had 38 hemorrhagic events related to head and neck cancer that were managed with endovascular means. Of these, 23 were localized to the external carotid artery (ECA) branches and five localized to the ECA main trunk; nine were related to the common carotid artery (CCA) or internal carotid artery (ICA), and one event was related to the innominate artery. Seven events related to the CCA/ICA or innominate artery were managed with endovascular sacrifice, whereas three cases were managed with a flow-preserving approach (covered stent). Only one patient developed permanent hemiparesis. In two of the three cases where the flow-preserving approach was used, the covered stent eventually became exposed via the overlying soft tissue defect, and definitive management using carotid revascularization or resection was employed to prevent further hemorrhage. In cases of soft tissue necrosis, vascularized tissues were used to cover the great vessels as applicable. The use of modern endovascular approaches for management of acute CBS yields optimal results and should be employed in a coordinated manner by the head and neck surgeon and the neurointerventionalist. 4. Laryngoscope, 2016 127:383-390, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  5. Endovascular Treatment of Unruptured A1 Segment Aneurysms

    Science.gov (United States)

    Xiaochuan, Huo; Xiaoyun, Sun; Youxiang, Li; Ning, Guan; Wenshi, Guo; Junsheng, Luo

    2013-01-01

    Summary Aneurysms of the A1 segment of the anterior cerebral artery (A1A) are rare and challenging to treat. Less information is available regarding their management by endovascular approach. We evaluated our experience of endovascular treatment in 15 patients with unruptured A1As. We retrospectively reviewed unruptured A1As treated by embolization at our hospital. The clinical data and angiographic results were reviewed. A special technique involving shaping microcatheter tips was used for catheterization. From September 2009 to December 2012, 15 patients presenting with unruptured A1As were identified. All the patients were treated by selective embolization including five patients with balloon-assisted coiling (BAC) or stent-assisted coiling (SAC). These adjunctive techniques were used to catheterize the sac safely or to protect a branch at the neck. According to the location and direction of the aneurysm, “Z-shaped”, “S-Shaped” or “U-Shaped” microcatheter tip shaping was used for microcatheter positioning and stabilization. All patients showed an excellent clinical outcome. A complete aneurysm occlusion was obtained in all the patients. Endovascular treatment of A1As is feasible and associated with good results. Because of their location and close relationship with perforators, endovascular treatment of A1As sometimes requires the use of BAC or SAC. The microcatheter tip shaping technique is very important for coiling. Our results suggest that endovascular treatment is a suitable therapeutic option for unruptured A1As when the aneurysm size is optimal for embolization. PMID:23693042

  6. Endovascular vein harvest: systemic carbon dioxide absorption.

    Science.gov (United States)

    Maslow, Andrew M; Schwartz, Carl S; Bert, Arthur; Hurlburt, Peter; Gough, Jeffrey; Stearns, Gary; Singh, Arun K

    2006-06-01

    Endovascular vein harvest (EDVH) requires CO(2) insufflation to expand the subcutaneous space, allowing visualization and dissection of the saphenous vein. The purpose of this study was to assess the extent of CO(2) absorption during EDVH. Prospective observational study. Single tertiary care hospital. Sixty patients (30 EDVH and 30 open-vein harvest) undergoing isolated coronary artery bypass graft surgery. Hemodynamic, procedural, and laboratory data were collected prior to (baseline), during, and at it the conclusion (final) of vein harvesting. Data were also collected during cardiopulmonary bypass (CPB). Data were compared by using t tests, analysis of variance, and correlation statistics when needed. There were significant increases in arterial CO(2) (PaCO(2), 35%) and decreases in pH (1.35%) during EDVH. These were associated with increases in heart rate, mean blood pressure, and cardiac output. Within the EDVH group, greater elevations (>10 mmHg) in PaCO2 were more likely during difficult harvest procedures, and these patients exhibited greater increase in heart rate. Elevated CO(2) persisted during CPB, requiring higher systemic gas flows and greater use of phenylephrine to maintain desired hemodynamics. EDVH was associated with systemic absorption of CO(2). Greater absorption was more likely in difficult procedures and was associated with greater hemodynamic changes requiring medical therapy.

  7. Resuscitative endovascular balloon occlusion of the aorta in trauma patients in youth.

    Science.gov (United States)

    Norii, Tatsuya; Miyata, Shin; Terasaka, Yusuke; Guliani, Sundeep; Lu, Stephen W; Crandall, Cameron

    2017-05-01

    Resuscitative endovascular balloon occlusion of the aorta (REBOA) has received increasing attention for critically uncontrolled hemorrhagic shock. However, the efficacy of REBOA in patients in youth is unknown. The aim of this study was to evaluate the mortality and characteristics of patients of age ≤18 years with severe traumatic injury who received REBOA. We retrospectively analyzed observational cohort data from the Japan Trauma Data Bank (JTDB) from 2004 to 2015. All patients ≤18 years old who underwent REBOA were included. Clinical characteristics and mortalities were analyzed and compared among patients ≤15 years old (young children) and 16-18 years old (adolescents). Of the 236,698 patients in the JTDB (2004-2015), 22,907 patients were 18 years old or younger. A total of 3,440 patients without survival data were excluded. Of the remaining 19,467, 54 (0.3%) patients underwent REBOA, among which 15 (27.8%) were young children. Both young children and adolescents who underwent REBOA were seriously injured (median Injury Severity Score [ISS], 41 and 38, respectively). Also, 53.3% of young children and 38.5% of adolescents survived to discharge after undergoing REBOA. In a cohort of young trauma patients from the JTDB who underwent REBOA to control hemorrhage, we found that both young children and adolescents who underwent REBOA were seriously injured and had an equivalent survival rate compared to the reported survival rate from studies in adults. REBOA treatment may be a reasonable option in severely injured young patients in the appropriate clinical settings. Further prospective studies are needed to confirm our findings. Epidemiologic study, level III; therapeutic study, level IV.

  8. Hybrid endovascular treatment of an aortic root and thoracoabdominal aneurysm in a high-risk patient with Marfan syndrome.

    Science.gov (United States)

    Gelpi, Guido; Mazzaccaro, Daniela; Romagnoni, Claudia; Contino, Monica; Antona, Carlo

    2013-05-01

    This report describes the hybrid endovascular treatment of an aortic root dilatation and a thoracoabdominal aneurysm in a high-risk patient with Marfan syndrome. A 50-year-old male, in hemodialysis for polycystic kidney and polycystic liver, was referred to our department for aortic root dilatation of 5 cm and a 6.3-cm thoracoabdominal aneurysm . He already underwent surgical repair of abdominal aortic aneurysm 10 years ago, complicated by pseudoaneurysm of the proximal anastomosis that had been treated in another center, with an endoprosthesis. The patient underwent aortic root replacement, aortic valve sparing operation, and rerouting of the superior mesenteric artery and celiac trunk to the ascending aorta. The thoracoabdominal aneurysm was excluded with an endoprosthesis few days after the surgical step. The 12-month computed tomography scan confirmed the complete exclusion of the thoracoabdominal aneurysm.

  9. Endovascular Intervention for Acute Ischemic Stroke in Light of Recent Trials

    Directory of Open Access Journals (Sweden)

    Kenan Alkhalili

    2014-01-01

    Full Text Available Three recently published trials, MR RESCUE, IMS III, and SYNTHESIS Expansion, evaluating the efficacy and safety of endovascular treatment of acute ischemic stroke have generated concerns about the future of endovascular approach. However, the tremendous evolution that imaging and endovascular treatment modalities have undergone over the past several years has raised doubts about the validity of these trials. In this paper, we review the role of endovascular treatment strategies in acute ischemic stroke and discuss the limitations and shortcomings that prevent generalization of the findings of recent trials. We also provide our experience in endovascular treatment of acute ischemic stroke.

  10. Content Validation and Evaluation of an Endovascular Teamwork Assessment Tool.

    Science.gov (United States)

    Hull, L; Bicknell, C; Patel, K; Vyas, R; Van Herzeele, I; Sevdalis, N; Rudarakanchana, N

    2016-07-01

    To modify, content validate, and evaluate a teamwork assessment tool for use in endovascular surgery. A multistage, multimethod study was conducted. Stage 1 included expert review and modification of the existing Observational Teamwork Assessment for Surgery (OTAS) tool. Stage 2 included identification of additional exemplar behaviours contributing to effective teamwork and enhanced patient safety in endovascular surgery (using real-time observation, focus groups, and semistructured interviews of multidisciplinary teams). Stage 3 included content validation of exemplar behaviours using expert consensus according to established psychometric recommendations and evaluation of structure, content, feasibility, and usability of the Endovascular Observational Teamwork Assessment Tool (Endo-OTAS) by an expert multidisciplinary panel. Stage 4 included final team expert review of exemplars. OTAS core team behaviours were maintained (communication, coordination, cooperation, leadership team monitoring). Of the 114 OTAS behavioural exemplars, 19 were modified, four removed, and 39 additional endovascular-specific behaviours identified. Content validation of these 153 exemplar behaviours showed that 113/153 (73.9%) reached the predetermined Item-Content Validity Index rating for teamwork and/or patient safety. After expert team review, 140/153 (91.5%) exemplars were deemed to warrant inclusion in the tool. More than 90% of the expert panel agreed that Endo-OTAS is an appropriate teamwork assessment tool with observable behaviours. Some concerns were noted about the time required to conduct observations and provide performance feedback. Endo-OTAS is a novel teamwork assessment tool, with evidence for content validity and relevance to endovascular teams. Endo-OTAS enables systematic objective assessment of the quality of team performance during endovascular procedures. Copyright © 2016. Published by Elsevier Ltd.

  11. Evaluation of the outcomes of endovascular management for patients with head and neck cancers and associated carotid blowout syndrome of the external carotid artery

    International Nuclear Information System (INIS)

    Chang, F.-C.; Luo, C.-B.; Lirng, J.-F.; Lin, C.-J.; Wu, H.-M.; Hung, S.-C.; Guo, W.-Y.; Teng, M.M.H.; Chang, C.-Y.

    2013-01-01

    Aim: To evaluate factors related to the technical and haemostatic outcomes of endovascular management in patients with head and neck cancers (HNC) associated with carotid blowout syndrome (CBS) of the external carotid artery (ECA). Materials and methods: Between 2002 and 2011, 34 patients with HNC with CBS involving branches of the ECA underwent endovascular therapy. Treatment included embolization with microparticles, microcoils, or acrylic adhesives. Fisher's exact test was used to examine demographic features, clinical and angiographic severities, and clinical and imaging findings as predictors of endovascular management outcomes. Results: Technical success and immediate haemostasis were achieved in all patients. Technical complications were encountered in one patient (2.9%). Rebleeding occurred in nine patients (26.5%). Angiographic vascular disruption grading from slight (1) to severe (4) revealed that the 18 patients with acute CBS had scores of 2 (2/18, 11.1%), 3 (3/18, 16.7%), and 4 (13/18, 72.2%). The 16 patients with impending and threatened CBS had scores of 1 (1/16, 6.25%), 2 (5/16, 31.25%), and 3 (10/16, 62.5%; p = 0.0003). For the 25 patients who underwent preprocedural computed tomography (CT)/magnetic resonance imaging (MRI) examinations within 3 months of treatment, the agreement between clinical and imaging findings reached the sensitivity, specificity, and kappa values for recurrent tumours (1, 0.7143, 0.7826), soft-tissue defect (0.9091, 0.3333, 0.2424), and sinus tract/fistula (0.4737, 0, 0.4286). Conclusion: Endovascular management for patients with CBS of the ECA had high technical success and safety but was associated with high rebleeding rates. We suggest applying aggressive post-procedural follow-up and using preprocedural CT/MRI to enhance the periprocedural diagnosis

  12. Advances in endovascular treatment of critical limb ischemia.

    LENUS (Irish Health Repository)

    Yan, Bryan P

    2011-04-01

    Critical limb ischemia (CLI) represents the most severe clinical manifestation of peripheral arterial disease. In the absence of timely revascularization, CLI carries high risk of mortality and amputation. Over the past decade, endovascular revascularization has rapidly become the preferred primary treatment strategy for CLI, especially for the treatment of below-the-knee disease. Advances in percutaneous devices and techniques have expanded the spectrum of patients with CLI who are deemed candidates for revascularization. This review will focus on advances in endovascular options for the treatment of CLI, in particular for below-the-knee disease.

  13. Enhancing brain lesions after endovascular treatment of aneurysms

    DEFF Research Database (Denmark)

    Cruz, J P; Marotta, T; O'Kelly, C

    2014-01-01

    Complications of endovascular therapy of aneurysms mainly include aneurysm rupture and thromboembolic events. The widespread use of MR imaging for follow-up of these patients revealed various nonvascular complications such as aseptic meningitis, hydrocephalus, and perianeurysmal brain edema. We...... present 7 patients from 5 different institutions that developed MR imaging-enhancing brain lesions after endovascular therapy of aneurysms, detected after a median time of 63 days. The number of lesions ranged from 4-46 (median of 10.5), sized 2-20 mm, and were mostly in the same vascular territory used...

  14. ENDOVASCULAR TREATMENT FOR ACUTE DISORDERS OF MESENTERIC CIRCULATION

    Directory of Open Access Journals (Sweden)

    S. A. Prozorov

    2016-01-01

    Full Text Available An acute disorder of mesenteric circulation is a serious disease with high mortality. It occurs much more often due to the arterial flow impairment, and less often due to the venous blood flow disturbance. Etiology: thrombosis, embolism, compression of the lumen under dissection. To restore the mesenteric blood flow endovascular techniques are performed: mechanical recanalization, balloon angioplasty, stent installation, thrombolysis, tromboaspiration and their various combinations. If recanalization of the superior mesenteric artery is unable to be performed, hybrid operations are carried out anterogradely: retrograde stent installation during laparotomy. The review shows that endovascular methods is a promising direction of treatment for acute mesenteric ischemia.

  15. Endovascular retrieval of a CardioMEMS heart failure system

    Directory of Open Access Journals (Sweden)

    Arun Reghunathan, MD

    2018-04-01

    Full Text Available As the creation and utilization of new implantable devices increases, so does the need for interventionalists to devise unique retrieval mechanisms. This report describes the first endovascular retrieval of a CardioMEMS heart failure monitoring device. A 20-mm gooseneck snare was utilized in conjunction with a 9-French sheath and Envoy catheter for retrieval. The patient suffered no immediate postprocedural complications but died 5 days after the procedure from multiorgan failure secondary to sepsis. Keywords: CardioMEMS heart failure system, Endovascular retrieval

  16. Off-the-shelf multibranched endograft for urgent endovascular repair of thoracoabdominal aortic aneurysms.

    Science.gov (United States)

    Gallitto, Enrico; Gargiulo, Mauro; Freyrie, Antonio; Pini, Rodolfo; Mascoli, Chiara; Ancetti, Stefano; Faggioli, Gianluca; Stella, Andrea

    2017-09-01

    The aim of this paper was to report early and midterm results of endovascular repair of urgent thoracoabdominal aortic aneurysms (TAAAs) by the off-the-shelf multibranched Zenith t-Branch endograft (Cook Medical, Bloomington, Ind). Between January 2014 and April 2016, all patients with urgent TAAAs (asymptomatic with diameter >8 cm, symptomatic, or ruptured TAAAs) and aortoiliac anatomic feasibility underwent endovascular repair by t-Branch and were prospectively enrolled. Clinical, morphologic, intraoperative, and postoperative data were recorded. Follow-up was performed by duplex ultrasound, contrast-enhanced duplex ultrasound, and computed tomography angiography. Early end points were technical success (absence of type I or type III endoleak, loss of target visceral vessels [TVVs], conversion to open repair, or 24-hour mortality), spinal cord ischemia, and 30-day mortality. Follow-up end points were survival, TVV patency, type I or type III endoleaks, and freedom from reintervention. Seventeen patients (male, 71%; age, 73 ± 6 years; American Society of Anesthesiologists class 3/4, 60%/40%) affected by type II (47%), III (29%), and IV (24%) TAAAs were enrolled. The indications for t-Branch were as follows: contained TAAA rupture, four (24%); symptomatic TAAA (pain or peripheral embolism), four (24%); and TAAA diameter ≥8 cm, nine (52%). The mean TAAA diameter was 80 ± 19 mm, with 63 TVVs. Fifteen patients (87%) needed adjunctive intraoperative procedures: 14 proximal thoracic endografts (thoracic endovascular aortic repair), 1 left carotid-subclavian bypass, 2 endovascular hypogastric branches, and 2 surgical iliac conduits. In four cases (24%), a significant malorientation (≥60 degrees) of the main body occurred during t-Branch deployment. Technical success was achieved in 14 cases (82%), with technical failures consisting of the loss of three renal arteries (TVV patency, 95%). Spinal cord ischemia occurred in one case (6%) with temporary

  17. Iliac artery recanalization of chronic occlusions to facilitate endovascular aneurysm repair.

    Science.gov (United States)

    Vallabhaneni, Raghuveer; Sorial, Ehab E; Jordan, William D; Minion, David J; Farber, Mark A

    2012-12-01

    Concurrent iliac occlusion and abdominal aortic aneurysm is rare. Traditionally, the endovascular approach to these patients has consisted of aortouniiliac devices combined with femoral-femoral bypass. With improved facility of endovascular techniques, standard bifurcated endografts represent an alternative option in these patients. This study examined outcomes of patients undergoing iliac recanalization and traditional bifurcated endovascular aneurysm repair in the face of access vessel occlusion. Outcomes of patients at three academic tertiary referral centers who underwent attempted iliac recanalization of chronic iliac occlusions and concurrent endovascular aneurysm repair of an infrarenal aortic aneurysm were retrospectively reviewed. Patients with acute iliac thrombosis and those with severely stenotic (but patent) iliac vessels were excluded. During a 6-year period, 15 occluded iliac arteries were treat