WorldWideScience

Sample records for underwent conventional angiography

  1. Imaging of the digital arteries: Digital subtraction angiography versus conventional angiography

    International Nuclear Information System (INIS)

    Menanteau, B.P.; Treutenaere, J.M.; Marcus, C.; Ladam, V.; Gausserand, F.

    1986-01-01

    The authors report their experience with the use of digital subtraction angiography (DSA) and conventional angiography of the hand. Of the 95 patients in the study group, 80 underwent conventional angiography and 15 underwent DSA. They analyzed the studies with regard to the type and amount of contrast agent used, the number of radiographs needed, and the diagnostic quality of the images. Conventional angiography often requires general anesthesia, magnification, and pharmaco-angiographic techniques to improve the image-based diagnosis. In comparison with conventional angiography, intraarterial DSA is characterized by improved contrast sensitivity and inferior spatial resolution. However, DSA provides images as acceptable as those of conventional angiography. Smaller catheters can be used, and the examination is performed under local anesthesia. The authors conclude that intraarterial DSA is now the technique of choice for examining patients with chronic ischemia of the hand

  2. Comparison of spiral CT angiography with conventional digital subtraction angiography in the evaluation of renal transplant donors: a pilot study

    International Nuclear Information System (INIS)

    Chu, C.; Young, N.; Lau, H.

    2001-01-01

    Conventional digital subtraction renal arteriography (IA-DSA) has been traditionally used as the preoperative imaging modality for assessment of renal vascular anatomy for renal transplant donors. This study evaluates the potential use of spiral CT angiography in replacing IA-DSA in the preoperative assessment of this group of patients. Seven patients underwent both spiral CT angiography and IA-DSA between October 1997 and April 1998. It is concluded that spiral CT angiography can demonstrate the number, length and location of renal arteries and it is suggested that spiral CT angiography can potentially replace IA-DSA in the preoperative assessment of renal donors. Copyright (2001) Blackwell Science Pty Ltd

  3. Comparison of magnetic resonance angiography and conventional angiography in sickle cell disease: clinical significance and realibility

    International Nuclear Information System (INIS)

    Kandeel, A.Y.; Zimmerman, R.A.; Ohene-Frempong, K.

    1996-01-01

    We retrospectively reviewed the medical records and conventional angiograms of 21 patients with known sickle cell disease, who underwent a total of 50 magnetic resonance imaging (MRI) and magnetic resonance angiography (MRA) studies. MRA and conventional angiography were assessed separately for evidence of stenosis or occulusion. Follow up MRI/MRA studies were also assessed for evidence of progression, regression or stability of the disease in these patients. In the carotid circulation, MRA made the correct diagnosis in 85% of the vessels evaluated with a sensitivity of 80.5% and a specificity of 94%. MRA was also found to show evidence of disease progression, more often than did MRI or the clinical condition of the patients. (orig.)

  4. Multidetector-row CT angiography of hepatic artery: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Jeong, Yong Yeon; Yoon, Woong; Kim, Jae Kyu; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun

    2003-01-01

    To determine the usefulness of three-dimensional CT angiography using multidetector-row CT (MD-CT) for delineating the arterial anatomy of the liver. Hepatic arterial three-dimensional CT angiography was performed using MDCT (lightspeed Qx/I; GE medical systems, milwaukee, Wis., U.S.A.) in 45 patients with HCC undergoing conventional angiography for transcatheter hepatic arterial chemoembolization. The scanning parameters during the early arterial phase were 2.5 mm slice thickness, 7.5 mm rotation of table speed, and a pitch of 3. Images were obtained by one radiologist using maximum intensity projection from axial CT images obtained during the early arterial phase. Two radiologists blinded to the findings of conventional angiography independently evaluated the hepatic arterial anatomy and the quality of the images obtained. Compared with conventional angiography, reader A correctly evaluated the hepatic arterial anatomy depicted at three-dimensional CT angiography. Reader B's evaluation was correct in 40 of 45 patients. Interobserver agreement was good (kappa value, 0.73), and both readers assessed the quality of three-dimensional CT angiography as excellent. Three-dimensional CT angiography using MDCT was accurate for delineating the arterial anatomy of the liver, and interobserver agreement was good. The modality may provide, prior to conventional angiography, valuable information regrading a patient's hepatic arterial anatomy

  5. Conventional cerebral angiography in occlusive cerebrovascular disease

    International Nuclear Information System (INIS)

    Caplan, L.R.; Wolpert, S.M.

    1987-01-01

    Treatment of the patient with occlusive vascular lesions of the extracranial and intracranial arteries will depend on the location, nature, and severity of the vascular disease and the general and neurologic condition of the patient. At present, standard angiography is the best method of opacifying the vascular system to gain critical information about the vascular lesion

  6. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography.

    Science.gov (United States)

    Kadziela, Jacek; Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure.

  7. Conventional and CT angiography in children: dosimetry and dose comparisons

    International Nuclear Information System (INIS)

    Frush, Donald P.; Yoshizumi, Terry

    2006-01-01

    Tremendous advances have been made in imaging in children with both congenital and acquired heart disease. These include technical advances in cardiac catheterization and conventional angiography, especially with advancements in interventional procedures, as well as noninvasive imaging with MR and CT angiography. With rapid advances in multidetector CT (MDCT) technology, most recently 64-detector array systems (64-slice MDCT), have come a number of advantages over MR. However, both conventional and CT angiography impart radiation dose to children. Although the presence of radiation exposure to children has long been recognized, it is apparent that our ability to assess this dose, particularly in light of the rapid advancements, has been limited. Traditional methods of dosimetry for both conventional and CT angiography are somewhat cumbersome or involve a potential for substantial uncertainty. Recent developments in dosimetry, including metal oxide semiconductor field effect transistors (MOSFET) and the availability of anthropomorphic, tissue-equivalent phantoms have provided new opportunities for dosimetric assessments. Recent work with this technology in state-of-the-art cardiac angiography suites as well as with MDCT have offered direct comparisons of doses in infants and children undergoing diagnostic cardiac evaluation. It is with these dose data that assessment of risks, and ultimately the assessment of risk-benefit, can be better achieved. (orig.)

  8. Prospective comparison of MR angiography and color duplex US with conventional angiography for peripheral arterial occlusive disease

    International Nuclear Information System (INIS)

    Mulligan, S.A.; Matsuda, T.; Lanzer, P.; Gross, G.; Routh, W.; Keller, F.; Koslin, D.B.; Berland, L.; Fields, M.; Doyle, M.; Cranney, G.; Lee, J.; Pohost, G.

    1990-01-01

    This paper evaluates color Doppler US (CDUS) and MR angiographic (MRA) assessment of peripheral vascular disease of the lower extremities, using blinded prospective comparison with conventional angiography. Conventional angiography, two-dimensional inflow MRA, and CDUS were performed in 12 patients. Four diagnostic categories were used to grade arterial lesions by evaluating peak velocity. Revascularization interventions were planned by the vascular surgeon, blinded from the imaging method utilized and from data derived from CDUS, MRA, and conventional angiography

  9. Digital subtraction cerebral angiography by intraarterial injection: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Brant-Zawadzki, M.; Gould, R.; Norman, D.; Newton, T.H.; Lane, B.

    1983-01-01

    For 4 months, a prototype digital subtraction system was used to obtain images of the cerebral vasculature after intraarterial contrast injections. In 12 instances, the intraarterial injections were recorded with both a digital subtraction unit and conventional direct magnification film-screen system. The digital subtraction and conventional film subtraction images were compared and graded for quality and information content by three skilled observers. In addition, quantitative measurements of contrast-detail performance and spatial resolution were obtained on both the digital system and the screen-film imaging chain. In a clinical setting, both the digital subtraction and conventional film-screen systems provided similar quality images and angiographic information. Contrast-detail curves demonstrated that digital subtraction angiography outperformed conventional film technique for low-contrast objects. Digital subtraction angiography also reduced the time required to obtain the angiogram, markedly reduced film cost, and lowered the contrast agent burden

  10. Collateral vessels in moyamoya disease : comparison of MR and MRA with conventional angiography

    International Nuclear Information System (INIS)

    Shim, Joo Eun; Yoon, Dae Young; Yi, Jeong Geun; Kim, Ho Chul; Choi, Chul Sun; Bae, Sang Hoon

    1998-01-01

    To determine the value of magnetic resonance imaging (MR) and magnetic resonance angiography (MRA) in assessing collateral vessels of moyamoya disease. Twenty-four patients with moyamoya disease who underwent MR, 3D TOF MRA, and conventional angiography participated in this study. Two radiologists working independently and with no knowledge of the angiographic findings, interpreted the MR and MRA images. To determine the presence of parenchymal and leptomeningeal collaterals (48 hemispheres) and transdural collaterals (38 hemispheres in 19 patients were depicted by angiography of the external carotid), the findings were compared with those of angiography. Parenchymal, leptomeningeal, and transdural collaterals were depicted by conventional angiography in 34 (71%), 32 (67%), and 11 (29%) hemispheres respectively. The sensitivity and specificity of MR/MRA for collateral vessels were 79.1/88.1 % for parenchymal collaterals, 72.1/88.1 % for leptomeningeal collaterals, and 0.1/18.1 % for transdural collaterals, respectively. Respective sensitivity and specificity of MR/MRA were 88.94/94.1% for leptomeningeal collaterals, and 18.93/55.1 % for transdural collaterals, when the prominent posterior cerebral and external carotid artery were regarded as secondary signs of leptomeningeal and transdural collateral vessels. In moyamoya disease, MR and MRA are useful imaging modalities for the assessment of collateral vessels. The prominent posterior cerebral artery and external carotid artery can be useful secondary signs of leptomeningeal and transdural collateral vessels. (author). 18 refs., 2 figs

  11. Conventional renal angiography versus renal digital subtraction angiography (DSA) in the study of renovascular hypertension

    International Nuclear Information System (INIS)

    Essinger, A.; Morsier, B. de; Narbel, M.; Raimondi, S.

    1988-01-01

    A cost-benefit analysis comparing conventional renal angiography, IV and IA DSA and spot film cameras has been made in order to quantify the advantages and disadvantages of these techniques in screening for renal artery stenosis. DSA is the best modality of imaging, using very little films, easy to archive, with a spatial resolution inferior to conventional angiography but partially compensated by contrast resolution. The surface dose per image using a 512/512 matrix is two thirds less than a conventional film, giving thus an acceptable dose as long as technical personnel is well trained and thus the number of exposures is kept low. Spot film camera, due to its excellent spatial resolution, its low radiation dose and its low price, can also be used as a screening procedure but requires an arterial injection. DSA has furthermore the advantage of quantifying renal artery stenosis making future percutaneous transluminal angioplasty easier

  12. Combined use of intraarterial digital subtraction angiography with conventional retrograde brachial vertebral angiography

    International Nuclear Information System (INIS)

    Yamaguchi, Tatsuo; Ogawa, Toshihide; Inugami, Atsushi; Kawata, Yasushi; Shishido, Fumio; Uemura, Kazuo

    1985-01-01

    For 102 patients who had the examination of conventional bilaterally retrograde brachial vertebral angiography (retrograde VAG), intraarterial digital subtraction angiography (DSA) was successively performed to investigate steno-occlusive lesions of proximal vertebral and subclavian arteries. All the patients had no complication due to the DSA procedure. In 50% of 72 ischemic stroke cases, positive findings were found either in the origin of the vertebral artery or in the subclavian artery. Stenosis of more than 50% of the lumen of the vertebral artery were found in 14% of the cases at the origin of the right one and also in 14% in the left one. Occlusion of the vertebral artery was found in 4% in the left side only. In 30 cases with non-ischemic brain diseases, positive findings were noted in 10%. Intraarterial DSA combined with retrograde VAG was thought to be useful, especially in the examination for ischemic stroke. (author)

  13. Retrospective analysis of patients for development of nephrogenic systemic fibrosis following conventional angiography using gadolinium-based contrast agents.

    Science.gov (United States)

    Hoppe, Hanno; Spagnuolo, Sara; Froehlich, Johannes M; Nievergelt, Helga; Dinkel, Hans-Peter; Gretener, Silvia; Thoeny, Harriet C

    2010-03-01

    The purpose was to retrospectively review the data of 27 patients with renal insufficiency who underwent conventional angiography with gadolinium-based contrast agents (GDBCA) as alternative contrast agents and assess the occurrence of nephrogenic systemic fibrosis (NSF) together with associated potential risk factors. This HIPAA-compliant study had institutional review board approval, and informed consent was waived. Statistical analysis was performed for all available laboratory and clinical data, including dermatology reports. Type and amount of the GDBCA used were recorded for angiography and additional MRI studies, if applicable. Serum creatinine levels (SCr) pre- and post-angiography were recorded, and estimated glomerular filtration rates (eGFR) were calculated. Ten female and 17 male patients who underwent angiography with GDBCA were included. The mean amount of GDBCA administered was 44 +/- 15.5 ml (range 15-60 ml) or 0.24 + 0.12 mmol/kg (range 0.1-0.53 mmol/kg). At the time of angiography all patients had renal insufficiency (eGFR <60 ml/min/1.73 m(2)). Mean eGFR pre-angiography was 26 ml/min/1.73 m(2) and 33 ml/min/1.73 m(2) post-angiography. The mean follow-up period covers 28 months, range 1-84 months. Additional MRI studies with GDBCA administration were performed in 15 patients. One patient with typical skin lesions had developed biopsy-confirmed NSF. Conventional arterial angiography with GDBCA may play a role in the development of NSF in patients with renal insufficiency. Alternative contrast agents, such as CO(2) angiography or rather the use of low doses of iodinated contrast agents, should be considered in these patients.

  14. Retrospective analysis of patients for development of nephrogenic systemic fibrosis following conventional angiography using gadolinium-based contrast agents

    International Nuclear Information System (INIS)

    Hoppe, Hanno; Spagnuolo, Sara; Froehlich, Johannes M.; Thoeny, Harriet C.; Nievergelt, Helga; Dinkel, Hans-Peter; Gretener, Silvia

    2010-01-01

    The purpose was to retrospectively review the data of 27 patients with renal insufficiency who underwent conventional angiography with gadolinium-based contrast agents (GDBCA) as alternative contrast agents and assess the occurrence of nephrogenic systemic fibrosis (NSF) together with associated potential risk factors. This HIPAA-compliant study had institutional review board approval, and informed consent was waived. Statistical analysis was performed for all available laboratory and clinical data, including dermatology reports. Type and amount of the GDBCA used were recorded for angiography and additional MRI studies, if applicable. Serum creatinine levels (SCr) pre- and post-angiography were recorded, and estimated glomerular filtration rates (eGFR) were calculated. Ten female and 17 male patients who underwent angiography with GDBCA were included. The mean amount of GDBCA administered was 44 ± 15.5 ml (range 15-60 ml) or 0.24 + 0.12 mmol/kg (range 0.1-0.53 mmol/kg). At the time of angiography all patients had renal insufficiency (eGFR 2 ). Mean eGFR pre-angiography was 26 ml/min/1.73 m 2 and 33 ml/min/1.73 m 2 post-angiography. The mean follow-up period covers 28 months, range 1-84 months. Additional MRI studies with GDBCA administration were performed in 15 patients. One patient with typical skin lesions had developed biopsy-confirmed NSF. Conventional arterial angiography with GDBCA may play a role in the development of NSF in patients with renal insufficiency. Alternative contrast agents, such as CO 2 angiography or rather the use of low doses of iodinated contrast agents, should be considered in these patients. (orig.)

  15. Retrospective analysis of patients for development of nephrogenic systemic fibrosis following conventional angiography using gadolinium-based contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Hoppe, Hanno; Spagnuolo, Sara; Froehlich, Johannes M.; Thoeny, Harriet C. [University Hospital Bern, Institute of Diagnostic, Interventional, and Pediatric Radiology, Inselspital, Bern (Switzerland); Nievergelt, Helga [University Hospital Bern, Clinic of Dermatology, Bern (Switzerland); Dinkel, Hans-Peter [Hospital Landshut, Institute of Diagnostic and Interventional Radiology, Landshut (Germany); Gretener, Silvia [University Hospital of Bern, Division of Vascular Medicine, Swiss Cardiovascular Center, Bern (Switzerland)

    2010-03-15

    The purpose was to retrospectively review the data of 27 patients with renal insufficiency who underwent conventional angiography with gadolinium-based contrast agents (GDBCA) as alternative contrast agents and assess the occurrence of nephrogenic systemic fibrosis (NSF) together with associated potential risk factors. This HIPAA-compliant study had institutional review board approval, and informed consent was waived. Statistical analysis was performed for all available laboratory and clinical data, including dermatology reports. Type and amount of the GDBCA used were recorded for angiography and additional MRI studies, if applicable. Serum creatinine levels (SCr) pre- and post-angiography were recorded, and estimated glomerular filtration rates (eGFR) were calculated. Ten female and 17 male patients who underwent angiography with GDBCA were included. The mean amount of GDBCA administered was 44 {+-} 15.5 ml (range 15-60 ml) or 0.24 + 0.12 mmol/kg (range 0.1-0.53 mmol/kg). At the time of angiography all patients had renal insufficiency (eGFR <60 ml/min/1.73 m{sup 2}). Mean eGFR pre-angiography was 26 ml/min/1.73 m{sup 2} and 33 ml/min/1.73 m{sup 2} post-angiography. The mean follow-up period covers 28 months, range 1-84 months. Additional MRI studies with GDBCA administration were performed in 15 patients. One patient with typical skin lesions had developed biopsy-confirmed NSF. Conventional arterial angiography with GDBCA may play a role in the development of NSF in patients with renal insufficiency. Alternative contrast agents, such as CO{sub 2} angiography or rather the use of low doses of iodinated contrast agents, should be considered in these patients. (orig.)

  16. Clinical and echocardiographic findings of patients with suspected acute pulmonary thromboembolism who underwent computed tomography pulmonary angiography

    Directory of Open Access Journals (Sweden)

    Atoosa Adibi

    2016-01-01

    Full Text Available Background: The aim of the study was to determine the correlation between clinical and echocardiographic findings and risk factors of patients with suspected acute pulmonary thromboembolism (PTE who underwent computed tomography pulmonary angiography (CTPA. Materials and Methods: In this cross-sectional study, 310 hospitalized patients aged >18 years with high clinical suspicion of PTE referred to imaging center of our hospital from different wards for CTPA were enrolled. The frequency of different clinical presentations, risk factors, items of Wells' criteria, and echocardiographic findings was compared in patients with and without PTE, which have been diagnosed according to the CTPA results. Results: PTE was diagnosed in 53 (17.1% of patients with suspected PTE. From clinical manifestations, tachypnea, pleuritic chest pain, and edema of lower extremities were significantly more frequent among patients with PTE (P < 0.05. Major surgery was the risk factor which was significantly more prevalent among patients with PTE (P < 0.05. Frequency of all criteria of Wells' criteria, except hemoptysis, was significantly higher in patients with PTE (P < 0.05. The frequency of all studied echocardiographic variables was significantly higher in patients with PTE (P < 0.05. Conclusion: It is suggested that we could use the results of this study for utilizing the diagnostic process of PTE in patients with highly clinical suspicion of PTE and providing more validated decision. Using the results of this study, we could identify high-risk patients and made appropriate risk assessment for better management of patients with suspected PTE as well as reduce the rate of unnecessary CTPA and its related adverse consequences.

  17. Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Feger, S.; Rief, M.; Zimmermann, E.; Richter, F.; Roehle, R. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, M. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Institut fuer Radiologie, Berlin (Germany); Schoenenberger, E. [Medizinische Hochschule Hannover, Department of Medicine, Hannover (Germany)

    2015-07-15

    To evaluate patient acceptance of noninvasive imaging tests for detection of coronary artery disease (CAD), including single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), stress perfusion magnetic resonance imaging (MRI), coronary CT angiography (CTA) in combination with CT myocardial stress perfusion (CTP), and conventional coronary angiography (CCA). Intraindividual comparison of perception of 48 patients from the CORE320 multicentre multinational study who underwent rest and stress SPECT-MPI with a technetium-based tracer, combined CTA and CTP (both with contrast agent, CTP with adenosine), MRI, and CCA. The analysis was performed by using a validated questionnaire. Patients had significantly more concern prior to CCA than before CTA/CTP (p < 0.001). CTA/CTP was also rated as more comfortable than SPECT-MPI (p = 0.001). Overall satisfaction with CT was superior to that of MRI (p = 0.007). More patients preferred CT (46 %; p < 0.001) as a future diagnostic test. Regarding combined CTA/CTP, CTP was characterised by higher pain levels and an increased frequency of angina pectoris during the examination (p < 0.001). Subgroup analysis showed a higher degree of pain during SPECT-MPI with adenosine stress compared to physical exercise (p = 0.016). All noninvasive cardiac imaging tests are well accepted by patients, with CT being the preferred examination. (orig.)

  18. Gadolinium-enhanced MR angiography of arterial occlusive disease in lower extremity : comparison with conventional digital subtraction angiography

    International Nuclear Information System (INIS)

    Shin, Sang June; Koh, Young Hwan; Cha, Joo Hee; Kim, Hyu Beom; Chung, Jin Wook; Park, Jae Hyung

    2000-01-01

    To compare the diagnostic value of gadolinium-enhanced MR angiography with that of conventional digital subtraction angiography for the evaluation of lower extremity arterial occlusive diseases. In 26 patients with symptomatic lower extremity arterial occlusive disease, both conventional digital subtraction angiography (DSA) and gadolinium-enhanced MR angiography (CE-MRA) were performed during the same week. MR angiography was performed using three-dimensional gradient-echo acquisition before, and two sequential acquisitions after, the administration of gadolinium (0.2 mmol/kg). In 23 patients, two separate, contiguous areas were scanned using additional doses. In three patients, only one field with a suspicious lesion was scanned. Three radiologists independently analyzed the CE-MRA and DSA findings of each vascular segment (20 segments per arterial tree) for the presence of obstructive lesions; the grade assigned was either mild or none (less than 50%), stenotic (50%-99%), or occlusion (100%). From among a total of 462 segments, DSA detected 99 which were significantly narrowed (stenosis, 33; occlusion, 66). Using MR angiography, 102 segments (stenosis 39; occlusion, 63) were identified, and 94 lesions (stenosis, 32; occlusion, 62) were graded correctly. Seven lesions were overestimated and four were underestimated. For the detection of hemodynamically significant stenosis or occlusions using MR angiography, sensitivity, specificity, and diagnostic accuracy were 95%, 98%, and 98% (G=3D0.995, P less than 0.001), respectively. To prove the absence of lesions, we repeated DSA in two patients with arterial spasm due to puncture. Three occluded segments seen on DSA, which revealed intact segments on MR angiography, suggested slow distal flow after reconstitution. For the evaluation of lower extremity arterial occlusive disease, the diagnostic value of gadolinium-enhanced MR angiography is comparable with that of digital subtraction angiography. The advantages of the

  19. CT coronary angiography versus conventional invasive coronary angiography. The view of the referring physician

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, Martin H. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiology; Universitaetsspital Bern (Switzerland). Dept. fuer Diagnostische, Interventionelle und Paediatrische Radiologie; Zimmermann, E.; Hamm, B. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiology; Dewey, M.

    2014-12-15

    Assessment of experience gained by local referring physicians with the procedure of coronary computed tomographic angiography (CCTA) in the everyday clinical routine. A 25-item questionnaire was sent to 179 physicians, who together had referred a total of 1986 patients for CCTA. They were asked about their experience to date with CCTA, the indications for coronary imaging, and their practice in referring patients for noninvasive CCTA or invasive catheter angiography. 53 questionnaires (30%) were assessable, corresponding to more than 72% of the patients referred. Of the referring physicians who responded, 94% saw a concrete advantage of CCTA in the treatment of patients, whereby 87% were 'satisfied' or 'very satisfied' with the reporting. For excluding coronary heart disease (CHD) where there was a low pre-test probability of disease, the physicians considered CCTA to be superior to conventional coronary diagnosis (4.2 on a scale of 1-5) and vice versa for acute coronary syndrome (1.6 of 5). The main reasons for unsuitability of CCTA for CT diagnosis were claustrophobia and the absence of a sinus rhythm. The level of exposure to radiation in CCTA was estimated correctly by only 42% of the referring physicians. 90% of the physicians reported that their patients evaluated their coronary CT overall as 'positive' or 'neutral', while 87% of the physicians whose patients had undergone both procedures reported that the patients had experienced CCTA as the less disagreeable of the two. CCTA is accepted by the referring physicians as an alternative imaging procedure for the exclusion of CHD and received a predominantly positive assessment from both the referring physicians and the patients.

  20. Comparison of MR angiography with conventional angiography in cervical and intracranial vascular disease

    International Nuclear Information System (INIS)

    Choi, D. S.; Chang, K. H.; Jung, H. W.; Han, M. H.

    1995-01-01

    To assess the usefulness of magnetic resonance angiography (MRA) in evaluation of stenosis of carotid and large cerebral vessels and cerebral aneurysm. Twenty-seven patients with either arterial stenosis in cervical or intracranial major vessels (n = 18) or cerebral aneurysm (n = 8) or both (n 1) were examined with both MRA and conventional angiography (CA). MRA was performed with 3D TOF technique with magnetization transfer suppression at 1.5T system (Magnetom, Siemens, Germany); both intracranial MRA and cervical MRA in 16 patients, intracranial MRA only in the remaining patients. For evaluation of arterial stenosis, 32 carotid bifurcations and 383 segments of intracranial major vessels were assessed in blind fashion, and were compared with those of CA. Each arterial segment was arbitrarily classified into one of five grades (< 10, 10-49, 50-74, 75-99, 100%) for carotid bifurcation and one of four (< 10, 10-49, 50-99, 100%) for intracranial vessels. For aneurysm, its location, size shape and direction were compared. For arterial stenosis, concordance rate between MRA and CA was 88% (28/32) in carotid bifurcation and 89% (340/383) in intracranial vessels. All discordant cases were overgraded on MRA. For aneurysm, 7 of 9 were demonstrated on both MRA and CA, one of which was partially demonstrated on MRA. One of the other two patients showed aneurysm only on MRA, whereas the remaining one revealed aneurysm only on CA. MRA may be performed as a screening test for occlusive disease of cervical and major intracranial vessels and cerebral aneurysm

  1. Radiation exposure in X-ray angiography and comparisons between digital and conventional methods of imaging

    International Nuclear Information System (INIS)

    Schaberg, J.

    1987-01-01

    The more recent developments and techniques in the field of angiography are examined for associated radiation exposure risks for patients and investigators and then compared to the conventional methods of angiography. It could be shown that digital subtraction angiography is generally associated with a lesser risk of somatic exposure of the patient, provided that the equipment used offers an adjustable useful-beam range and focus. The fact that above-table X-ray tubes are now generally replaced with X-ray systems installed under the examination table permits the relatively high doses, to which investigators are exposed during angiography, to be reduced by a factor of 3. (DG) [de

  2. Breath-hold two-dimensional MR angiography of coronary arteries. Comparison with conventional coronary angiography in ten cases

    International Nuclear Information System (INIS)

    Li Liwei; Zhang Wanshi; Liu Chaozhong; Lu Xiaoyan; Xu Jiaxing

    1997-01-01

    Purpose: To assess the diagnostic value of two-dimensional coronary magnetic resonance (MR) angiography in patients evaluated for ischemic heart disease. Materials and methods: Ten patients who underwent selective cardiac catheterization with coronary MR angiography were evaluated with two-dimensional coronary MR angiography. Coronary MR angiography was performed with breath-hold fat-suppressed ECG-gated Turbo-FLASH with K-space segmentation using a 1.5 T imager. Results: The left main coronary artery, proximal left anterior descending artery, circumflex artery and right coronary artery were demonstrated in all cases. Continuous segments (mean) of left anterior descending, circumflex and right coronary arteries visualized on MRA were 6.72 +- 3.16 cm, 3.67 +- 4.81 cm and 7.93 +- 3.12 cm respectively. The overall sensitivity for detection of hemodynamically significant coronary artery lesion (≥50%) was 62.5% respectively. Conclusion: Breath-hold two-dimensional coronary MR angiography was useful in showing relatively long segments of the main coronary arteries and also has potential in depicting hemodynamically significant coronary artery lesions

  3. Radiation Exposure During Uterine Fibroid Embolization (UFE): A Confounder-Controlled Comparison Between a State-of-the-Art Angiography Unit and a Conventional Angiography unit.

    Science.gov (United States)

    Sommer, Christof-Matthias; Voigt, Wieland; Klapp Oliger, Michel; Schlett, Christopher L; Erpenbach, Stefan; Thomas, Katrina; Hatopp, Andreas; Kurz, Patrick; Richter, Goetz M

    2018-03-01

     To compare radiation exposure of a state-of-the-art and a conventional angiography unit in patients undergoing uterine fibroid embolization (UFE).  Between January 2009 and December 2016, 286 patients underwent UFE in our Interdisciplinary Fibroid Center. The inclusion criteria for this retrospective analysis were first-time transarterial embolization for symptomatic fibroids, bilateral embolization, procedures applying a state-of-the-art (Group 1) or a conventional angiography unit (Group 2), and bilateral technical success with an adequate embolization endpoint after the injection of microspheres. Study endpoints included radiation exposure, major complications, morphological success (MRI), and clinical success (questionnaire on quality-of-life). Propensity score matching controlled for confounders.  The inclusion criteria were met by 58 (Group 1) and 177 (Group 2) patients. After propensity score matching, there was no significant difference between Group 1 (n = 46) and Group 2 (n = 92) regarding age, body-mass index, volume of the dominant fibroid and the uterus, fluoroscopy time, and amount of embolic agent (p ≥ 0.10 each). The dose-area product was significantly lower in Group 1 than in Group 2 (1159.0 cGycm 2 vs. 3123.5 cGycm 2 ; p  0.99). There were no significant differences between both groups regarding shrinkage of the dominant fibroid and the uterus and no relevant differences regarding patient-reported quality-of-life.  A state-of-the-art angiography unit has the potential to reduce radiation exposure in patients undergoing UFE without increasing the risk of major complications and with comparably high morphological and clinical success.   · A state-of-the-art angiography unit potentially reduces radiation exposure in patients undergoing UFE.. · Reduced radiation exposure does not seem to negatively influence the rate of major complications.. · Reduced exposure does not seem to negatively affect morphological and clinical

  4. Symptomatic middle cerebral artery stenosis and occlusion. Comparison of three-dimensional time-of-flight magnetic resonance angiography with conventional angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, Motoshi; Yano, Hirohito; Shinoda, Jun; Funakoshi, Takashi [Daiyukai General Hospital, Ichinomiya, Aichi (Japan); Kumagai, Morio

    1994-10-01

    The usefulness of magnetic resonance (MR) angiography using the three-dimensional time-of-flight method for the characterization of symptomatic middle cerebral artery (MCA) occlusive lesions was evaluated in 10 patients with MCA occlusion and 10 with MCA stenosis. All lesions were symptomatic and documented by conventional angiography. There was no false-negative MR angiogram that failed to demonstrate the MCA occlusive lesion. MR angiography correctly evaluated the location of lesions and the difference between stenosis and occlusion. Stenosis appeared as a focal signal loss (<1.0cm) of the MCA at the site of stenosis, and occlusion as a complete signal loss of the MCA distal to the site of occlusion. However, MR angiography could not distinguish diffuse stenosis and one point stenosis demonstrated by conventional angiography. MR angiography is a useful noninvasive diagnostic method for evaluating occlusive lesions of the MCA in symptomatic patients. (author).

  5. Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism : a prospective study

    NARCIS (Netherlands)

    Oudkerk, M; van Beek, EJR; Wielopolski, P; van Ooijen, PMA; Brouwers-Kuyper, EMJ; Bongaerts, AHH; Berghout, A

    2002-01-01

    Background Diagnostic strategies for pulmonary embolism are complex and consist of non-invasive diagnostic tests done to avoid conventional pulmonary angiography as much as possible. We aimed to assess the diagnostic accuracy of magnetic resonance angiography (MRA) for the diagnosis of pulmonary

  6. Conventional digital subtraction x-ray angiography versus magnetic resonance angiography in the evaluation of carotid disease: patient satisfaction and preferences

    Energy Technology Data Exchange (ETDEWEB)

    U-King-Im, J.M. E-mail: jhg21@cam.ac.uk; Trivedi, R.; Cross, J.; Higgins, N.; Graves, M.; Kirkpatrick, P.; Antoun, N.; Gillard, J.H

    2004-04-01

    AIM: To compare conventional digital subtraction x-ray angiography (DSA) and contrast-enhanced magnetic resonance angiography (MRA) of the carotid arteries in terms of patient satisfaction and preferences. METHODS: One hundred and sixty-seven patients with symptomatic carotid artery disease, who underwent both DSA and MRA, were prospectively recruited in this study. Patients' perceptions of each method were assessed by the use of a questionnaire after each procedure. Main outcome measures were anxiety, pain, satisfaction rate and patient preferences. RESULTS: DSA generated more anxiety and pain during the procedure, but the severity of these ill-effects was mild. Satisfaction rates for each method were similar. More patients were, however, willing to have a repeat MRA compared with DSA (67 versus 41%). The majority of patients (62%) preferred MRA over DSA (31%). The shorter MRA imaging time was found to be a significant factor in patients' acceptance of the technique. The main reasons cited by patients for their dislike of a particular procedure was noise and claustrophobia for MRA and invasiveness, pain and post-procedural bed rest for DSA. CONCLUSIONS: MRA is the method that is preferred by the majority of patients, although the actual disutility of DSA may be small. Assuming equal diagnostic accuracy, our data supports replacement of DSA by MRA for routine carotid imaging.

  7. Conventional digital subtraction x-ray angiography versus magnetic resonance angiography in the evaluation of carotid disease: patient satisfaction and preferences

    International Nuclear Information System (INIS)

    U-King-Im, J.M.; Trivedi, R.; Cross, J.; Higgins, N.; Graves, M.; Kirkpatrick, P.; Antoun, N.; Gillard, J.H.

    2004-01-01

    AIM: To compare conventional digital subtraction x-ray angiography (DSA) and contrast-enhanced magnetic resonance angiography (MRA) of the carotid arteries in terms of patient satisfaction and preferences. METHODS: One hundred and sixty-seven patients with symptomatic carotid artery disease, who underwent both DSA and MRA, were prospectively recruited in this study. Patients' perceptions of each method were assessed by the use of a questionnaire after each procedure. Main outcome measures were anxiety, pain, satisfaction rate and patient preferences. RESULTS: DSA generated more anxiety and pain during the procedure, but the severity of these ill-effects was mild. Satisfaction rates for each method were similar. More patients were, however, willing to have a repeat MRA compared with DSA (67 versus 41%). The majority of patients (62%) preferred MRA over DSA (31%). The shorter MRA imaging time was found to be a significant factor in patients' acceptance of the technique. The main reasons cited by patients for their dislike of a particular procedure was noise and claustrophobia for MRA and invasiveness, pain and post-procedural bed rest for DSA. CONCLUSIONS: MRA is the method that is preferred by the majority of patients, although the actual disutility of DSA may be small. Assuming equal diagnostic accuracy, our data supports replacement of DSA by MRA for routine carotid imaging

  8. Comparison of 16-row multislice CT angiography with conventional angiography for detection and evaluation of intracranial aneurysms

    International Nuclear Information System (INIS)

    Donmez, Halil; Serifov, Elman; Kahriman, Guven; Mavili, Ertugrul; Durak, Ahmet Candan; Menkue, Ahmet

    2011-01-01

    Purpose: The aim of this study is to compare the diagnostic performance of 16-row computed tomographic angiography (MDCTA) with digital subtraction angiography (DSA) for the detection and characterization of intracranial aneurysms in patients with nontraumatic subarachnoid hemorrhages (SAH). Materials and methods: One-hundred and twelve consecutive patients with suspected intracranial aneurysm underwent both 16-row MDCTA and DSA. The MDCT angiograms were interpreted in a blinded fashion by using combination with VRI, MIP and MPR techniques. Sensitivity specificity and accuracy were calculated for the CTA and DSA. The results were compared with each other. The DSA reader's interpretation was accepted as the reference standard. Results: A total of 164 aneurysms were detected at DSA in 112 patients, no aneurysms were detected by DSA and MDCTA in 16 patients. Eight aneurysms were missed by MDCTA. The overall sensitivity, specificity, and accuracy of MDCTA on a per-aneurysm basis were 95.1%, 94.1%, and 95%, respectively. According to the size of the aneurysm less than 3 mm; sensitivity, specificity and diagnostic accuracy of MDCTA were 86.1%, 94.1%, 88.6%, respectively. Conclusion: This study suggests that MDCTA is equally as sensitive as DSA in the detection of intracranial aneurysms of greater than 3 mm, and it also reveals 100% detection rate for ruptured aneurysms.

  9. Angiography

    International Nuclear Information System (INIS)

    Grinnell, V.S.; Mehringer, C.M.; Hieshima, G.B.

    1987-01-01

    The history of angiography is short, with its centennial approaching. A very brief review of milestones begins with the discovery of x-rays in 1895. Only a few months later contrast agents too toxic for human use were being injected into cadavers, severed limbs, and animals. The next major developments came in the late 1970s when percutaneous translumbar aortography and cerebral angiography were described. Contrast agents were now less toxic, and clinically useful angiography was a reality. In 1953 a technique for percutaneous vascular catheterization which formed the basis of many catheterization techniques to follow was described. In the 1970s the development of less invasive diagnostic methods such as computed tomography and diagnostic ultrasound decreased the indications for angiography, but newer interventional techniques such as embolization therapy and angioplasty have taken up the slack. Angiography remains the most important way to demonstrate vascular diseases graphically. Specific techniques such as angioplasty and digital subtraction angiography will be dealt with in other chapters. The authors hope to provide an overview of major areas of angiographic utilization. The basic techniques of arterial puncture and catheterization have been well described elsewhere

  10. A comparison of patient dose levels between 3/4 vessel conventional angiography and computed tomography angiography during examinations to investigate subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Spanton, David; Strudwick, Ruth M.

    2007-01-01

    The aim of this study was to investigate and compare the levels of ionising radiation dose received by patients whilst undergoing radiological examination for Subarachnoid haemorrhage by conventional angiography (single and bi plane) and computed tomography angiography. The results obtained from previous examinations have been compared to consider which method of investigation delivers the lowest ionising radiation dose to the patient. Consideration was also given to comparing single plane angiography to bi plane angiography as empirical evidence suggested that radiologists received no formal training and only a small amount of informal training on newly installed equipment at the hospital in which the research was carried out. Would this lead to patients being inadvertently exposed to increased radiation as radiologists familiarised themselves with the equipment? The dose received by 30 patients examined for SAH by each modality was converted to effective dose (mSv) for comparison. These results were then further compared by removing the lowest and highest recorded doses to eliminate any bias that may have been caused by skewed data. The results showed that CTA consistently delivered a lower dose to patients than single or bi plane angiography and that bi plane delivered a lower mean average dose than single plane angiography, with or without any skewed data

  11. Single Center Retrospective Analysis of Conventional and Radial TIG Catheters for Transradial Diagnostic Coronary Angiography.

    Science.gov (United States)

    Vorpahl, Marc; Koehler, Till; Foerst, Jason; Panagiotopoulos, Spyridon; Schleiting, Heinrich; Koss, Klaus; Ziegler, Gunda; Brinkmann, Hilmar; Seyfarth, Melchior; Tiroch, Klaus

    2015-01-01

    Current guidelines favor the radial approach for coronary angiography. Therefore, specialty radial diagnostic catheters were designed to engage both coronary arteries with a single device. However, it is unclear if single catheters are superior to conventional catheters. A retrospective analysis was performed of consecutive right radial coronary angiographies to determine catheter use, fluoroscopy time, radiation dosage, and consumption of contrast. Procedures were performed with a single TIG catheter or conventional catheters (CONV). Procedures with coronary artery bypass grafts or ventricular angiographies were excluded. 273 transradial procedures were performed successfully. 95 procedures were performed with CONV and 178 procedures with a TIG. Crossover to additional catheters was higher in TIG (15.2%) compared to CONV (5.3%, p = 0.02). Fluoroscopy time was comparable between CONV and TIG, without crossover (2.2 ± 1.2 min versus 2.3 ± 1.2 min; n.s.), however, greater in the case of crossover for CONV (5.8 ± 0.7) and TIG (7.6 ± 3.0; p = 0.0001). Radiation dosage was similar in CONV and the TIG, without crossover (1419 ± 1075, cGy∗cm(2) versus 1690 ± 1138; n.s.), however, greater for CONV (2374 ± 620) and TIG (3733 ± 2281, p = 0.05) with crossover. Overall, the amount of contrast was greater in TIG (56 ± 13 mL) versus CONV (48 ± 3 mL; p = 0.0003). CONV femoral catheters may be the primary choice for radial approach.

  12. Comparison of CO2 DSA and conventional angiography using non-ionic contrast media in lower extremity angiography

    International Nuclear Information System (INIS)

    Kim, Jae Kyu; Park, Sung Jae; Koh, Seok Wan; Seo, Jeong Jin; Kang, Heoung Keun; Chung, Hyon De

    1994-01-01

    The purpose of this study is to compare CO 2 DSA and nonionic contrast media angiography in respect to the quality of the opacification of collaterals and incidence of side-effects in peripheral occlusive arterial disease. Sixteen patients who were suspected to have peripheral occlusive arterial disease were performed angiography with nonionic contrast media and CO 2 at the same location with the same catheter. The causes of the lesions were atherosclerosis(n=7) and Buerger's disease(n=9). CO 2 DSA was compared with nonionic contrast media angiography in respect to the quality of image in the diagnosis of the lesions, opacifications of collaterals and side-effects. In atherosclerosis; quality of the images of CO 2 DSA was same as that of nonionic contrast media angiography in 6 patients and was poor in 1 patient; opacifications of collaterals of CO 2 DSA were same as that of nonionic contrast media angiography in 5 patients and was poor in 2 patients. In Buerger's disease; quality of the images of CO 2 DSA was same as that of nonionic contrast media angiography in 2 patients and was poor in 7 patients; opacifications of collaterals of CO 2 DSA were same as that of nonionic contrast media angiography in 1 patient and was poor in 8 patients. Leg pain was the only side-effect after CO 2 injection occurring in 4 out of 16 patients. CO 2 could be used as safe contrast media in patient with risk factors for nonionic contrast media and for diagnosis of the atherosclerosis in lower extremity. For the procedures such as vascular intervention requiring large amount of contrast media CO 2 could effectively replace nonionic contrast media

  13. Profile of conventional risk factors in patients presenting for coronary angiography in a tertiary care hospital

    International Nuclear Information System (INIS)

    Qureshi, N.S.

    2014-01-01

    The conventional risk factors for coronary artery disease (CAD) include hypertension, diabetes mellitus, hyperlipidaemia and cigarette smoking(1). There is a large body of evidence, which implicates these factors in the causation of coronary artery disease. Objective: To study the attern of the above-mentioned as well as additional risk factors including age, gender, family history, obesity and hepatitis B and C seropositivity in the population of patients undergoing coronary angiography at our tertiary care hospital.Methodology:In this cross-sectional survey, 465 patients undergoing coronary angiography were studied using a questionnaire as well as clinical and laboratory data. The information obtained included age, sex, clinical presentation, past medical history, family history, the presence or absence of previous ischemic heart disease, diabetes, hypertension and a history of smoking. A history of duration of diabetes and hypertension, their treatment and the presence or absence of complications was also noted. A proportion of patients had their fasting blood lipid levels measured. Height, weight and waist circumference as well as HepBsAg and anti-HCV levels were also determined.Results: The 465 patients studied included 383 males and 82 females. The mean age of all patients was 49.68 +- 0.464 years and the difference between genders was not significant. A past history of ischaemic heart disease was present in 31% of patients. Diabetes mellitus was present in 23% of males and 45% of females. A history of hypertension was present in 30.8% males and 70.7% of the females. Of the patients who could be studied, the mean LDL was 110.29 +- 1.706 mg/dL, the mean HDL was 41.01 +- 0.319 mg/dL and the mean TG was 189.67 +- 4.21 mg/dL. The difference in lipid profile values between male and female patients was not significant (p-value >0.05). Waist circumference was increased in 69.7% males and 93.9% females and here the difference between genders was significant, Hep

  14. Analysis of Complex Coronary Plaque in Multidetector Computed Tomography: Comparison with Conventional Coronary Angiography

    International Nuclear Information System (INIS)

    Kim, Dong Hyun; Bang, Duck Won; Cho, Yoon Haeng; Suk, Eun Ha

    2011-01-01

    To delineate complex plaque morphology in patients with stable angina using coronary computed tomographic angiography (CTA). 36 patients with complex plaques proven by conventional coronary angiography (CAG), who had taken CTA for evaluation of typical angina, were enrolled in this study. Intravascular ultrasonography (IVUS) was performed in 14 patients (16 lesions). We compared CTA with CAG for plaque features and analyzed vascular cutoff, intraluminal filling defect in a patent vessel, irregularity of plaque, and ulceration. Also, the density of plaque was evaluated on CTA. CAG and CTA showed complex morphology in 44 cases (100%) and 34 cases, (77%), respectively, with features including abrupt vessel cutoff (27 vs. 16%, κ=0.57), intraluminal filling defect (32 vs. 30%, κ=0.77), irregularity (75 vs. 52%, κ=0.52), and ulceration (16 vs. 11%, κ=0.60). CTA indicated that the complex lesions were hypodense (mean 66 ± 21 Houndsfield Units). CTA is a very accurate and useful non-invasive imaging modality for evaluating complex plaque in patients with typical angina.

  15. Analysis of Complex Coronary Plaque in Multidetector Computed Tomography: Comparison with Conventional Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hyun [Dept. of Radiology, Soonchunhyang University Hospital, Bucheon (Korea, Republic of); Bang, Duck Won; Cho, Yoon Haeng [Dept. of Internal Medicine, Soonchunhyang University Hospital, Bucheon (Korea, Republic of); Suk, Eun Ha [Dept. of Anesthyesiology and Pain Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2011-04-15

    To delineate complex plaque morphology in patients with stable angina using coronary computed tomographic angiography (CTA). 36 patients with complex plaques proven by conventional coronary angiography (CAG), who had taken CTA for evaluation of typical angina, were enrolled in this study. Intravascular ultrasonography (IVUS) was performed in 14 patients (16 lesions). We compared CTA with CAG for plaque features and analyzed vascular cutoff, intraluminal filling defect in a patent vessel, irregularity of plaque, and ulceration. Also, the density of plaque was evaluated on CTA. CAG and CTA showed complex morphology in 44 cases (100%) and 34 cases, (77%), respectively, with features including abrupt vessel cutoff (27 vs. 16%, {kappa}=0.57), intraluminal filling defect (32 vs. 30%, {kappa}=0.77), irregularity (75 vs. 52%, {kappa}=0.52), and ulceration (16 vs. 11%, {kappa}=0.60). CTA indicated that the complex lesions were hypodense (mean 66 {+-} 21 Houndsfield Units). CTA is a very accurate and useful non-invasive imaging modality for evaluating complex plaque in patients with typical angina.

  16. Magnetic resonance angiography (MRA) of the circle of Willis: a prospective comparison with conventional angiography in 54 subjects

    International Nuclear Information System (INIS)

    Patrux, B.; Laissy, J.P.; Jouini, S.; Kawiecki, W.; Coty, P.; Thiebot, J.

    1994-01-01

    We prospectively correlated the findings of magnetic resonance angiography (MRA) with those of transfemoral four-vessel angiography in 54 patients to investigate the direction of flow within the circle of Willis. Our primary goal was to assess the direction of flow using the size of the vessel and signal intensity, without saturation techniques. Analysis of the circle of Willis, especially the communicating arteries, was performed double-blind by two groups of two radiologists. Three types of arteries were identified: high flow or cross-cerebral circulation, patent and nonvisualised arteries. Cerebral angiography was the standard for comparison between the two methods. MRA did not reveal any arteries invisible on angiography, thus providing a specificity of 100%. The sensitivity of MRA was 89.2% for the anterior and 81.3% for the posterior communicating arteries, and 100% for the anterior, middle and posterior cerebral arteries. MRA was shown to be a useful technique for the assessment of patency of the circle of Willis. (orig.)

  17. Magnetic resonance angiography (MRA) of the circle of Willis: a prospective comparison with conventional angiography in 54 subjects

    Energy Technology Data Exchange (ETDEWEB)

    Patrux, B. (Neuroradiology, CHU Charles Nicolle, Rouen (France)); Laissy, J.P. (Neuroradiology, CHU Charles Nicolle, Rouen (France) Dept. of Radiology, CHU Bichat, Paris (France)); Jouini, S. (Neuroradiology, CHU Charles Nicolle, Rouen (France)); Kawiecki, W. (Siemens Medical Systems, Saint-Denis (France)); Coty, P. (Neuroradiology, CHU Charles Nicolle, Rouen (France)); Thiebot, J. (Neuroradiology, CHU Charles Nicolle, Rouen (France))

    1994-04-01

    We prospectively correlated the findings of magnetic resonance angiography (MRA) with those of transfemoral four-vessel angiography in 54 patients to investigate the direction of flow within the circle of Willis. Our primary goal was to assess the direction of flow using the size of the vessel and signal intensity, without saturation techniques. Analysis of the circle of Willis, especially the communicating arteries, was performed double-blind by two groups of two radiologists. Three types of arteries were identified: high flow or cross-cerebral circulation, patent and nonvisualised arteries. Cerebral angiography was the standard for comparison between the two methods. MRA did not reveal any arteries invisible on angiography, thus providing a specificity of 100%. The sensitivity of MRA was 89.2% for the anterior and 81.3% for the posterior communicating arteries, and 100% for the anterior, middle and posterior cerebral arteries. MRA was shown to be a useful technique for the assessment of patency of the circle of Willis. (orig.)

  18. Prospective evaluation of the development of contrast-induced nephropathy in patients with acute coronary syndrome undergoing rotational coronary angiography vs. conventional coronary angiography: CINERAMA study

    Directory of Open Access Journals (Sweden)

    Diego Fernández-Rodríguez

    2018-03-01

    Full Text Available Introduction and objectives: Rotational coronary angiography (RCA requires less contrast to be administered and can prevent the onset of contrast-induced nephropathy (CIN during invasive coronary procedures. The aim of the study is to evaluate the impact of RCA on CIN (increase in serum creatinine ≥0.5 mg/dL or ≥25% after an acute coronary syndrome. Methods: From April to September 2016, patients suffering acute coronary syndromes who underwent diagnostic coronary angiography, with the possibility of ad hoc coronary angioplasty, were prospectively enrolled. At the operator's discretion, patients underwent RCA or conventional coronary angiography (CCA. CIN (primary endpoint, as well as analytical, angiographic and clinical endpoints, were compared between groups. Results: Of the 235 patients enrolled, 116 patients received RCA and 119 patients received CCA. The RCA group was composed of older patients (64.0 ± 11.8 years vs. 59.7 ± 12.1 years; p = 0.006, a higher proportion of women (44.8 vs. 17.6%; p < 0.001, patients with a lower estimated glomerular filtration rate (76 ± 25 vs. 86 ± 27 ml/min/1.73 m2; p = 0.001, and patients who underwent fewer coronary angioplasties (p < 0.001 compared with the CCA group. Furthermore, the RCA group, received less contrast (113 ± 92 vs. 169 ± 103 ml; p < 0.001, including in diagnostic procedures (54 ± 24 vs. 85 ± 56 ml; p < 0.001 and diagnostic-therapeutic procedures (174 ± 64 vs. 205 ± 98 ml; p = 0.049 compared with the CCA group. The RCA group presented less CIN (4.3 vs. 22.7%; p < 0.001 compared to the CCA group, and this finding was maintained in the regression analysis (Adjusted relative risk: 0.868; 95% CI: 0.794–0.949; p = 0.002. There were no differences in clinical endpoints between the groups. Conclusions: RCA was associated

  19. Comparative study of conducting iliac angioplasties with digital subtraction and conventional angiography. Incidence on true (consumable) costs

    International Nuclear Information System (INIS)

    Brenot, P.; Raynaud, A.; Pernes, J.M.; Parola, J.L.; Gaux, J.C.

    1986-01-01

    Differences in time and cost were evaluated between the performance of iliac angioplasty with conventional (AC) and digital subtraction (AN) angiography, after a total of 27 angioplasties (13 with AC and 14 with AN). Excluding amortization of material and personnel costs, findings confirmed a certain number of advantages for AN: gain in time of about 34%, decrease of about 14% in charges, and notably of 83% in expenditure on films and 50% on contrast media [fr

  20. Use of the stereoscopic virtual reality display system for the detection and characterization of intracranial aneurysms: A Icomparison with conventional computed tomography workstation and 3D rotational angiography.

    Science.gov (United States)

    Liu, Xiujuan; Tao, Haiquan; Xiao, Xigang; Guo, Binbin; Xu, Shangcai; Sun, Na; Li, Maotong; Xie, Li; Wu, Changjun

    2018-07-01

    This study aimed to compare the diagnostic performance of the stereoscopic virtual reality display system with the conventional computed tomography (CT) workstation and three-dimensional rotational angiography (3DRA) for intracranial aneurysm detection and characterization, with a focus on small aneurysms and those near the bone. First, 42 patients with suspected intracranial aneurysms underwent both 256-row CT angiography (CTA) and 3DRA. Volume rendering (VR) images were captured using the conventional CT workstation. Next, VR images were transferred to the stereoscopic virtual reality display system. Two radiologists independently assessed the results that were obtained using the conventional CT workstation and stereoscopic virtual reality display system. The 3DRA results were considered as the ultimate reference standard. Based on 3DRA images, 38 aneurysms were confirmed in 42 patients. Two cases were misdiagnosed and 1 was missed when the traditional CT workstation was used. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the conventional CT workstation were 94.7%, 85.7%, 97.3%, 75%, and99.3%, respectively, on a per-aneurysm basis. The stereoscopic virtual reality display system missed a case. The sensitivity, specificity, PPV, NPV, and accuracy of the stereoscopic virtual reality display system were 100%, 85.7%, 97.4%, 100%, and 97.8%, respectively. No difference was observed in the accuracy of the traditional CT workstation, stereoscopic virtual reality display system, and 3DRA in detecting aneurysms. The stereoscopic virtual reality display system has some advantages in detecting small aneurysms and those near the bone. The virtual reality stereoscopic vision obtained through the system was found as a useful tool in intracranial aneurysm diagnosis and pre-operative 3D imaging. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Comparison of diagnostic accuracy of dual-source CT and conventional angiography in detecting congenital heart diseases

    International Nuclear Information System (INIS)

    Sedaghat, Fariborz; Pouraliakbar, Hamidreza; Motevalli, Marzieh; Karimi, Mohammad Ali; Armand, Sandbad

    2014-01-01

    Cardiac dual-source computed tomography (DSCT) is primarily used for coronary arteries. There are limited studies about the application of DSCT for congenital heart diseases. The aim of this study was to determine the diagnostic value of DSCT in the cardiac anomalies. The images of DSCTs and conventional angiographies of 36 patients (21 male; mean age: 8.5 month) with congenital heart diseases were reviewed and the parameters of diagnostic value of these methods were compared. Cardiac surgery was the gold standard. A total of 105 cardiac anomalies were diagnosed at surgery. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of DSCT were 98.25%, 97.9%, 98.1%, 99.07%, and 98.2%, respectively. The corresponding values of angiography were 95.04%, 98.7%, 97.8%, 98.1%, and 98%, respectively. Only one atrial septal defect (ASD) and two patent ductus arteriosus (PDA) were missed by DSCT. Angiography missed two ASD and two PDA. DSCT also provided important additional findings (n=35) about the intrathoracic or intraabdominal organs. DSCT is a highly accurate diagnostic modality for congenital heart diseases, obviating the need for invasive modalities. Beside its noninvasive nature, the advantage of DSCT over the angiography is its ability to provide detailed anatomical information about the heart, vessels, lungs and intraabdominal organs

  2. The value of magnetic resonance imaging for the detection of the bleeding source in non-traumatic intracerebral haemorrhages: a comparison with conventional digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lummel, Nina; Lutz, Juergen; Brueckmann, Hartmut; Linn, Jennifer [University of Munich, Department of Neuroradiology, Munich (Germany)

    2012-07-15

    Conventional digital subtraction angiography (DSA) is currently regarded as the gold standard in detecting underlying vascular pathologies in patients with intracerebral haemorrhages (ICH). However, the use of magnetic resonance imaging (MRI) in the diagnostic workup of ICHs has considerably increased in recent years. Our aim was to evaluate the diagnostic accuracy and yield of MRI for the detection of the underlying aetiology in ICH patients. Sixty-seven consecutive patients with an acute ICH who underwent MRI (including magnetic resonance angiography (MRA) and DSA during their diagnostic workup) were included in the study. Magnetic resonance images were retrospectively analysed by two independent neuroradiologists to determine the localisation and cause of the ICH. DSA was used as a reference standard. In seven patients (10.4%), a DSA-positive vascular aetiology was present (one aneurysm, four arteriovenous malformations, one dural arteriovenous fistula and one vasculitis). All of these cases were correctly diagnosed by both readers on MRI. In addition, MRI revealed the following probable bleeding causes in 39 of the 60 DSA-negative patients: cerebral amyloid angiopathy (17), cavernoma (9), arterial hypertension (8), haemorrhagic transformation of an ischaemic infarction (3) and malignant brain tumour with secondary ICH (2). Performing MRI with MRA proved to be an accurate diagnostic tool in detecting vascular malformations in patients with ICH. In addition, MRI provided valuable information regarding DSA-negative ICH causes, and thus had a high diagnostic yield in ICH patients. (orig.)

  3. Focal time-to-peak changes on perfusion MRI in children with Moyamoya disease: correlation with conventional angiography

    International Nuclear Information System (INIS)

    Choi, Hyun Seok; Kim, Dong-Seok; Shim, Kyu-Won; Kim, Jinna; Kim, Eun Soo; Lee, Seung-Koo

    2011-01-01

    Background: Moyamoya disease is a chronic progressive steno-occlusion of the distal internal carotid arteries with unknown etiology. As the classical presentation of childhood Moyamoya disease is ischemic stroke, cerebral hemodynamic evaluation is important for patient selection for surgery to prevent recurrent ischemic attacks. Perfusion MR imaging has been applied to evaluate cerebral hemodynamics. Purpose: To correlate the 'basal time-to-peak preservation sign', 'auto-synangiosis sign', and 'posterior involvement sign' on time-to-peak map of perfusion MRI with catheter angiography. Material and Methods: Thirty-four children (6.91 ± 3.08 years) with Moyamoya disease who underwent both perfusion-weighted MRI and catheter angiography were enrolled in this study. Given catheter angiography as a reference standard, basal time-to-peak preservation sign, auto-synangiosis sign, and posterior involvement sign were evaluated on time-to-peak maps. Results: The basal time-to-peak preservation sign was accurate for the diagnosis of childhood Moyamoya disease; both sensitivity and specificity were 100%. The auto-synangiosis sign showed lower sensitivity (65%), however, with an acceptable specificity (98%). The posterior involvement sign showed lower sensitivity (61%) but had an acceptable specificity (96%). Conclusion: The basal time-to-peak preservation sign may be a universal finding in childhood Moyamoya disease. The auto-synangiosis and posterior involvement sign may be useful in determining transdural collateral status and posterior circulation involvement in childhood Moyamoya disease

  4. Clinical evaluation of dual-energy bone removal in CT angiography of the head and neck: comparison with conventional bone-subtraction CT angiography

    International Nuclear Information System (INIS)

    Deng, K.; Liu, C.; Ma, R.; Sun, C.; Wang, X.-M.; Ma, Z.-T.; Sun, X.-L.

    2009-01-01

    Aim: To evaluate the bone-subtraction effect of dual-energy bone removal in computed tomography angiography (CTA) of the head and neck in comparison with conventional bone-subtraction CTA. Material and Methods: The study comprised 52 patients who were divided into two groups at random, and examined using dual-source CT for head and neck CTA. Dual-energy bone removal CTA and conventional bone-subtraction CTA were applied to each of the two groups, respectively. The bone subtraction was performed automatically in both methods. Vascular structures, as well as brain tissue remained visible. The subtracted images were further processed with maximum intensity projection (MIP) and volume-rendering technique (VRT) for image evaluation. Two experienced radiologists reviewed the resulting subtracted and non-subtracted volume data with respect to the delineation and detection of image quality and vascular pathology. Results: The means of the weighted CT dose index (CTDIvol) for bone-removal dual-energy CTA and conventional bone-subtraction CTA were 20.56 ± 0.01 mGy and 25.57 ± 0.56 mGy, respectively. There was a significant difference between them. The percentage of carotid and vertebral arteries and all other vessels that could be successfully assessed with these two methods were 87.8, 68, and 83%, and 93.5, 91.8, and 92.6%, respectively. There were no significant differences in the visualization of the carotid arteries; however, there were significant differences in the visualization of the vertebral arteries. Conclusion: Compared with conventional bone-subtraction CTA, dual-energy bone-removal CTA had a lower radiation dose. It eliminated most bones in the head and neck successfully; however, the bone subtraction effect around the vertebral artery was unsatisfactory. Dual-energy bone-removal CTA provides a new method for detecting vascular diseases in routine clinical work.

  5. Evaluation of variants in hepatic artery anatomy on conventional angiography in patients undergoing transarterial chemoembolization (tace): experience at siut

    International Nuclear Information System (INIS)

    Faiq, S.M.; Jesrani, A.; Jamal, M.; Lalwani, A.

    2017-01-01

    Objective: The purpose of this research is to evaluate common and uncommon variant of hepatic arterial anatomy that usually come across during Hepatic Angiographies. Study Design: Cross sectional study. Methods: This study included 50 patients having history of Hepatocellular Carcinoma from May to October 2015. Hepatic Angiography (Transarterial chemoembolization for management of Hepatoma and identification of classical and variant anatomy of hepatic artery) was evaluated in angiography unit. All procedures were performed on Digital Subtraction Angiography (DSA) machine (Toshiba KXO100 G). Selective DSA of the superior mesenteric artery and celiac trunk is performed initially to evaluate the frequency of normal and variant arterial anatomy and secondly to determine origin and course of tumor-feeding vessels. Evaluation of common and uncommon variants of hepatic arteries was done by using Michel’s classification as reference standard. Results: Age of the patient range from 40 – 80 years, 35 of whom were males. Fifty patients underwent angiographic procedure of viscera. Normal anatomy of hepatic artery was found in twenty eight (56%) cases. In six (12%) cases we found the replaced form of right hepatic artery (RHA) originating from visceral superior mesenteric artery. In five (10%) cases we found the replaced form of left hepatic artery (LHA) originating from left gastric artery (LGA), the combination of both these anomalies in one (2%) patient. Four (8%) cases had the left gastric artery giving rise to accessory left hepatic artery in conjunction with the common hepatic artery of celiac axis giving rise to typical right or left hepatic artery. In another four (8%) cases anatomic variation was noted in form of a dual arterial supply noted as common hepatic artery of celiac axis giving rise to typical left or right hepatic artery in conjunction with superior mesenteric artery giving rise to accessory right hepatic artery. In two (4%) cases superior mesenteric

  6. Vasovist-enhanced MR angiography

    International Nuclear Information System (INIS)

    Goyen, M.; Shamsi, K.; Schoenberg, S.O.

    2006-01-01

    Vasovist (MS-325) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. Vasovist reversibly binds to albumin, providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive testing to evaluate the safety and efficacy of the drug; the clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (AIOD, renal, pedal), examination of potential drug interaction with warfarin and comparison with XRA. The clinical trials show that Vasovist-enhanced MR angiography is safe and well-tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. (orig.)

  7. Vasovist-enhanced MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Goyen, M. [Univ. Medical Center, Hamburg-Eppendorf, Hamburg (Germany); Shamsi, K. [Berlex Lab., Inc., Montville, NJ (United States); Schoenberg, S.O. [Dept. of Clinical Radiology, Univ. Hospitals Grosshadern, Munich (Germany)

    2006-02-15

    Vasovist (MS-325) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. Vasovist reversibly binds to albumin, providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive testing to evaluate the safety and efficacy of the drug; the clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (AIOD, renal, pedal), examination of potential drug interaction with warfarin and comparison with XRA. The clinical trials show that Vasovist-enhanced MR angiography is safe and well-tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. (orig.)

  8. Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases

    Energy Technology Data Exchange (ETDEWEB)

    Krishnam, Mayil S. [University of California, Cardiovascular and Thoracic Imaging, UCI Medical Center, Irvine, CA (United States); Tomasian, Anderanik; Malik, Sachin; Ruehm, Stefan G. [University of California at Los Angeles, Department of Radiological Sciences, Ronald Reagan Medical Center, Los Angeles, CA (United States); Desphande, Vibhas; Laub, Gerhard [Siemens Medical Solutions, Los Angeles, CA (United States)

    2010-06-15

    The purpose of this study was to determine the image quality and diagnostic accuracy of three-dimensional (3D) unenhanced steady state free precession (SSFP) magnetic resonance angiography (MRA) for the evaluation of thoracic aortic diseases. Fifty consecutive patients with known or suspected thoracic aortic disease underwent free-breathing ECG-gated unenhanced SSFP MRA with non-selective radiofrequency excitation and contrast-enhanced (CE) MRA of the thorax at 1.5 T. Two readers independently evaluated the two datasets for image quality in the aortic root, ascending aorta, aortic arch, descending aorta, and origins of supra-aortic arteries, and for abnormal findings. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined for both datasets. Sensitivity, specificity, and diagnostic accuracy of unenhanced SSFP MRA for the diagnosis of aortic abnormalities were determined. Abnormal aortic findings, including aneurysm (n = 47), coarctation (n = 14), dissection (n = 12), aortic graft (n = 6), intramural hematoma (n = 11), mural thrombus in the aortic arch (n = 1), and penetrating aortic ulcer (n = 9), were confidently detected on both datasets. Sensitivity, specificity, and diagnostic accuracy of SSFP MRA for the detection of aortic disease were 100% with CE-MRA serving as a reference standard. Image quality of the aortic root was significantly higher on SSFP MRA (P < 0.001) with no significant difference for other aortic segments (P > 0.05). SNR and CNR values were higher for all segments on SSFP MRA (P < 0.01). Our results suggest that free-breathing navigator-gated 3D SSFP MRA with non-selective radiofrequency excitation is a promising technique that provides high image quality and diagnostic accuracy for the assessment of thoracic aortic disease without the need for intravenous contrast material. (orig.)

  9. Image quality and diagnostic accuracy of unenhanced SSFP MR angiography compared with conventional contrast-enhanced MR angiography for the assessment of thoracic aortic diseases

    International Nuclear Information System (INIS)

    Krishnam, Mayil S.; Tomasian, Anderanik; Malik, Sachin; Ruehm, Stefan G.; Desphande, Vibhas; Laub, Gerhard

    2010-01-01

    The purpose of this study was to determine the image quality and diagnostic accuracy of three-dimensional (3D) unenhanced steady state free precession (SSFP) magnetic resonance angiography (MRA) for the evaluation of thoracic aortic diseases. Fifty consecutive patients with known or suspected thoracic aortic disease underwent free-breathing ECG-gated unenhanced SSFP MRA with non-selective radiofrequency excitation and contrast-enhanced (CE) MRA of the thorax at 1.5 T. Two readers independently evaluated the two datasets for image quality in the aortic root, ascending aorta, aortic arch, descending aorta, and origins of supra-aortic arteries, and for abnormal findings. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were determined for both datasets. Sensitivity, specificity, and diagnostic accuracy of unenhanced SSFP MRA for the diagnosis of aortic abnormalities were determined. Abnormal aortic findings, including aneurysm (n = 47), coarctation (n = 14), dissection (n = 12), aortic graft (n = 6), intramural hematoma (n = 11), mural thrombus in the aortic arch (n = 1), and penetrating aortic ulcer (n = 9), were confidently detected on both datasets. Sensitivity, specificity, and diagnostic accuracy of SSFP MRA for the detection of aortic disease were 100% with CE-MRA serving as a reference standard. Image quality of the aortic root was significantly higher on SSFP MRA (P 0.05). SNR and CNR values were higher for all segments on SSFP MRA (P < 0.01). Our results suggest that free-breathing navigator-gated 3D SSFP MRA with non-selective radiofrequency excitation is a promising technique that provides high image quality and diagnostic accuracy for the assessment of thoracic aortic disease without the need for intravenous contrast material. (orig.)

  10. MR angiography with Vasovist

    Energy Technology Data Exchange (ETDEWEB)

    Goyen, Mathias [University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20251 Hamburg (Germany)], E-mail: goyen@uke.uni-hamburg.de

    2007-12-15

    Vasovist (Gadofosveset) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. This blood pool contrast agent reversibly binds to albumin providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive clinical and pre-clinical testing to evaluate the safety and efficacy of the drug. The clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (aorto-iliac, renal, pedal), examination of potential drug interaction with warfarin, and comparison with X-ray angiography. The clinical trials show that Vasovist-enhanced MR angiography is safe and well tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. This review article highlights the product characteristics of Vasovist, gives an overview of the clinical development program and discusses selected clinical applications.

  11. MR angiography with Vasovist

    International Nuclear Information System (INIS)

    Goyen, Mathias

    2007-01-01

    Vasovist (Gadofosveset) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. This blood pool contrast agent reversibly binds to albumin providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive clinical and pre-clinical testing to evaluate the safety and efficacy of the drug. The clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (aorto-iliac, renal, pedal), examination of potential drug interaction with warfarin, and comparison with X-ray angiography. The clinical trials show that Vasovist-enhanced MR angiography is safe and well tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. This review article highlights the product characteristics of Vasovist, gives an overview of the clinical development program and discusses selected clinical applications

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography uses a catheter, x-ray ... are the limitations of Catheter Angiography? What is Catheter Angiography? Angiography is a minimally invasive medical test ...

  13. Comparison of intra-aortic computed tomography angiography to conventional angiography in the presurgical visualization of the Adamkiewicz artery: first results in patients with thoracoabdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Clarencon, Frederic; Maria, Federico di; Cormier, Evelyne; Sourour, Nader; Gabrieli, Joseph; Iosif, Christina; Chiras, Jacques; Gaudric, Julien; Koskas, Fabien; Jenny, Catherine

    2013-01-01

    The aim of this study was to compare the sensitivity of intra-aortic computed tomography angiography (IA-CTA) to that of regular spinal digital subtraction angiography for the presurgical location of the Adamkiewicz artery (AKA). Thirty patients (21 males, 9 females; mean age 64 years) had an IA-CTA for the location of the AKA before surgery of aneurysm (n = 24) or dissection (n = 6) of the thoracoabdominal aorta. After femoral artery puncture, a pigtail catheter was positioned at the origin of the descending aorta. CT acquisition was performed with an intra-aortic iodinated contrast media injection (15 mL/s, 120 mL). The visualization of the AKA and the location of the feeder(s) to the AKA were independently evaluated by two observers. Interrater agreement was calculated using a kappa test. Spinal angiogram by selective catheterization was systematically performed to confirm the results of the IA-CTA. The AKA was visualized by the IA-CTA in 27/30 cases (90 %); in 26/31 (84 %) cases, the continuity with the aorta was satisfactorily seen. Interrater agreement was good for the visualization of the AKA and its feeder(s): 0.625 and 0.87, respectively. In 75 % of the cases for which the AKA was visualized, the selective catheterization confirmed the results of the IA-CTA. In the remaining 25 % of the cases, the selective catheterization could not be performed due to marked vessels' tortuosity or ostium stenosis. IA-CTA is a feasible technique in a daily practice that presents a good sensitivity for the location of the AKA. (orig.)

  14. Magnetic resonance angiography for patients with positional vertigo

    International Nuclear Information System (INIS)

    Seo, Toru; Tominaga, Satoru; Fujiki, Hiroya; Kumoi, Takeo.

    1993-01-01

    Magnetic resonance angiography (MRA) can image the blood vessels without invasion. Using MRA, we studied the vascular morphology of the vertebral artery in patients with positional nystagmus and vertigo. Fifteen patients without vestibular disorder such as benign positional vertigo were examined. Six cases underwent conventional vertebral angiography, including digital subtraction angiography (DSA) for comparison with MRA. In all cases. we observed the vertebral artery from the bifurcation to the basilar artery with MRA. In 12 cases, abnormal findings of elongation, bending, narrowing or obstruction of the vertebral artery were found. In five cases, arterial compression and elongation increased in association with head rotation. A difference in the vessel diameter on each side was observed in 4 cases. Accordingly, some abnormal vessels were found in 14 of 15 cases in our study. This rate was very close to previous results obtained with conventional angiography. In two cases, MRA findings differed from conventional angiography due to peculiar artifacts of MRA. Therefore, MRA may be the first choice for the patients with vertigo, followed by conventional angiography, if necessary. (author)

  15. Magnetic resonance angiography for patients with positional vertigo

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Toru; Tominaga, Satoru; Fujiki, Hiroya (Takarazuka City Hospital, Hyogo (Japan)); Kumoi, Takeo

    1993-11-01

    Magnetic resonance angiography (MRA) can image the blood vessels without invasion. Using MRA, we studied the vascular morphology of the vertebral artery in patients with positional nystagmus and vertigo. Fifteen patients without vestibular disorder such as benign positional vertigo were examined. Six cases underwent conventional vertebral angiography, including digital subtraction angiography (DSA) for comparison with MRA. In all cases. we observed the vertebral artery from the bifurcation to the basilar artery with MRA. In 12 cases, abnormal findings of elongation, bending, narrowing or obstruction of the vertebral artery were found. In five cases, arterial compression and elongation increased in association with head rotation. A difference in the vessel diameter on each side was observed in 4 cases. Accordingly, some abnormal vessels were found in 14 of 15 cases in our study. This rate was very close to previous results obtained with conventional angiography. In two cases, MRA findings differed from conventional angiography due to peculiar artifacts of MRA. Therefore, MRA may be the first choice for the patients with vertigo, followed by conventional angiography, if necessary. (author).

  16. Effects on costs of frontline diagnostic evaluation in patients suspected of angina: coronary computed tomography angiography vs. conventional ischaemia testing

    DEFF Research Database (Denmark)

    Nielsen, Lene H; Olsen, Jens; Markenvard, John

    2013-01-01

    group. The mean (SD) total costs per patient at the end of thefollow-up were 14% lower in the CTA group than in the ex-test group, € 1510 (3474) vs. €1777 (3746) (P = 0.03). CONCLUSION: Diagnostic assessment of symptomatic patients with a low-intermediate probability of CAD by CTA incurred lower costs......AIMS: The aim of this study was to investigate in patients with stable angina the effects on costs of frontline diagnostics by exercise-stress testing (ex-test) vs. coronary computed tomography angiography (CTA). METHODS AND RESULTS: In two coronary units at Lillebaelt Hospital, Denmark, 498...... patients were identified in whom either ex-test (n = 247) or CTA (n = 251) were applied as the frontline diagnostic strategy in symptomatic patients with a low-intermediate pre-test probability of coronary artery disease (CAD). During 12 months of follow-up, death, myocardial infarction and costs...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic ... called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a catheter makes it ...

  20. Three-dimensional (3D)- computed tomography bronchography and angiography combined with 3D-video-assisted thoracic surgery (VATS) versus conventional 2D-VATS anatomic pulmonary segmentectomy for the treatment of non-small cell lung cancer.

    Science.gov (United States)

    She, Xiao-Wei; Gu, Yun-Bin; Xu, Chun; Li, Chang; Ding, Cheng; Chen, Jun; Zhao, Jun

    2018-02-01

    Compared to the pulmonary lobe, the anatomical structure of the pulmonary segment is relatively complex and prone to variation, thus the risk and difficulty of segmentectomy is increased. We compared three-dimensional computed tomography bronchography and angiography (3D-CTBA) combined with 3D video-assisted thoracic surgery (3D-VATS) to perform segmentectomy to conventional two-dimensional (2D)-VATS for the treatment of non-small cell lung cancer (NSCLC). We retrospectively reviewed the data of randomly selected patients who underwent 3D-CTBA combined with 3D-VATS (3D-CTBA-VATS) or 2D-VATS at the Department of Thoracic Surgery, The First Affiliated Hospital of Soochow University Hospital, from January 2014 to May 2017. The operative duration of 3D group was significantly shorter than the 2D group (P 0.05). The extent of intraoperative bleeding and postoperative drainage in the 3D group was significantly lower than in the 2D group (P 3D group was shorter than in the 2D group (P 0.05). However, hemoptysis and pulmonary air leakage (>3d) occurred significantly less frequently in the 3D than in the 2D group (P 3D-CTBA-VATS is a more accurate and smooth technique and leads to reduced intraoperative and postoperative complications. © 2018 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  1. Preoperative cerebral aneurysm assessment by three-dimensional CT angiography. Feasibility of surgery without cerebral angiography

    International Nuclear Information System (INIS)

    Kashiwagi, Shiro; Yamashita, Katsuhiro; Kato, Shoichi; Ito, Haruhide; Kurokawa, Kensuke; Watanabe, Yutaka

    1999-01-01

    The purpose of this study is to assess the capability of three-dimensional CT angiography (3D-CTA) to replace conventional catheter angiography as a preoperative examination for unruptured intracranial aneurysms. A prospective study was designed to evaluate 18 patients with 20 unruptured intracranial aneurysms (13 middle cerebral artery aneurysms, 6 anterior communicating artery aneurysms, and 1 internal carotid posterior communicating artery aneurysm) who underwent surgery. There were 12 women and 6 men with the average age of 63 years old. All patients were initially diagnosed as having intracranial aneurysms by MR angiography, followed by 3D-CTA and conventional catheter angiography for confirmation. Three experienced neurosurgeons were in charge of the operations. One of the neurosurgeons (surgeon 1) was provided with only 3D-CTA as the preoperative radiological evaluation, while the others (surgeon 2 and 3) were given through assessments with MRA, 3D-CTA, and conventional angiography. Surgeon 1 carried out the operations under careful observation by the surgeons 2 and 3. Problems encountered by the surgeon 1 during surgery were recorded. Neck clipping in 19 aneurysms and dome wrapping in 1 were successfully accomplished. All patients were discharged without complication. Surgeries went smoothly in 16 aneurysms with 3D-CTA alone. Discrepancies between the 3D-CTA findings and microsurgical anatomy were noted in 4 aneurysms: the size of the neck was overestimated in 3 aneurysms, the relationships to parent arteries were obscure in 2 aneurysms, and a perforating artery problematic to neck clipping was missed in 1 aneurysms by 3D-CTA. The results of this study support the notion that 3D-CTA can replace conventional catheter angiography as preoperative examination in the majority of regular-sized anterior circulation aneurysms. Nevertheless, surgeons should recognize and be prepared for the fact that 3D-CTA can give false impression about the aneurysm neck and

  2. Comparative use of the computer-aided angiography and rapid prototyping technology versus conventional imaging in the management of the Tile C pelvic fractures.

    Science.gov (United States)

    Li, Baofeng; Chen, Bei; Zhang, Ying; Wang, Xinyu; Wang, Fei; Xia, Hong; Yin, Qingshui

    2016-01-01

    Computed tomography (CT) scan with three-dimensional (3D) reconstruction has been used to evaluate complex fractures in pre-operative planning. In this study, rapid prototyping of a life-size model based on 3D reconstructions including bone and vessel was applied to evaluate the feasibility and prospect of these new technologies in surgical therapy of Tile C pelvic fractures by observing intra- and perioperative outcomes. The authors conducted a retrospective study on a group of 157 consecutive patients with Tile C pelvic fractures. Seventy-six patients were treated with conventional pre-operative preparation (A group) and 81 patients were treated with the help of computer-aided angiography and rapid prototyping technology (B group). Assessment of the two groups considered the following perioperative parameters: length of surgical procedure, intra-operative complications, intra- and postoperative blood loss, postoperative pain, postoperative nausea and vomiting (PONV), length of stay, and type of discharge. The two groups were homogeneous when compared in relation to mean age, sex, body weight, injury severity score, associated injuries and pelvic fracture severity score. Group B was performed in less time (105 ± 19 minutes vs. 122 ± 23 minutes) and blood loss (31.0 ± 8.2 g/L vs. 36.2 ± 7.4 g/L) compared with group A. Patients in group B experienced less pain (2.5 ± 2.3 NRS score vs. 2.8 ± 2.0 NRS score), and PONV affected only 8 % versus 10 % of cases. Times to discharge were shorter (7.8 ± 2.0 days vs. 10.2 ± 3.1 days) in group B, and most of patients were discharged to home. In our study, patients of Tile C pelvic fractures treated with computer-aided angiography and rapid prototyping technology had a better perioperative outcome than patients treated with conventional pre-operative preparation. Further studies are necessary to investigate the advantages in terms of clinical results in the short and long run.

  3. DNA double-strand breaks as potential indicators for the biological effects of ionising radiation exposure from cardiac CT and conventional coronary angiography: a randomised, controlled study

    Energy Technology Data Exchange (ETDEWEB)

    Geisel, Dominik; Zimmermann, Elke; Rief, Matthias; Greupner, Johannes; Hamm, Bernd [Charite Medical School, Department of Radiology, Berlin (Germany); Laule, Michael; Knebel, Fabian [Charite Medical School, Department of Cardiology, Berlin (Germany); Dewey, Marc [Charite Medical School, Department of Radiology, Berlin (Germany); Charite, Institut fuer Radiologie, Berlin (Germany)

    2012-08-15

    To prospectively compare induced DNA double-strand breaks by cardiac computed tomography (CT) and conventional coronary angiography (CCA). 56 patients with suspected coronary artery disease were randomised to undergo either CCA or cardiac CT. DNA double-strand breaks were assessed in fluorescence microscopy of blood lymphocytes as indicators of the biological effects of radiation exposure. Radiation doses were estimated using dose-length product (DLP) and dose-area product (DAP) with conversion factors for CT and CCA, respectively. On average there were 0.12 {+-} 0.06 induced double-strand breaks per lymphocyte for CT and 0.29 {+-} 0.18 for diagnostic CCA (P < 0.001). This relative biological effect of ionising radiation from CCA was 1.9 times higher (P < 0.001) than the effective dose estimated by conversion factors would have suggested. The correlation between the biological effects and the estimated radiation doses was excellent for CT (r = 0.951, P < 0.001) and moderate to good for CCA (r = 0.862, P < 0.001). One day after radiation, a complete repair of double-strand breaks to background levels was found in both groups. Conversion factors may underestimate the relative biological effects of ionising radiation from CCA. DNA double-strand break assessment may provide a strategy for individualised assessments of radiation. (orig.)

  4. Contrast-Enhanced MR Angiography (CEMRA) in Peripheral Arterial Occlusive Disease (PAOD): conventional moving table technique versus hybrid technique

    International Nuclear Information System (INIS)

    Kalle, T. von; Gerlach, A.; Hatopp, A.; Klinger, S.; Prodehl, P.; Arlat, I.P.

    2004-01-01

    Patients and Methods: 80 patients (males n = 60, females n = 20, median age = 70 years, diabetics n = 27) with PAOD were examined with a 1,5T system (40 mT/m) using a dedicated phased array peripheral vascular coil. Protocol A consisted of a single injection of Gd-BOPTA with consecutive craniocaudal image acquisition and protocol B of two injections, with the first injection of Gd-BOPTA followed by image acquisition of the popliteocrural and pedal segments and the second injection followed by acquiring the aortoiliac and femoral segments (hybrid technique). The evaluation of the arterial system was directed to the iliac, femoral, popliteocrural and pedal arteries. Results: The visualization of the entire aortopedal vascular system was of diagnostically good or satisfactory quality in 16 of 40 patients using protocol A and in 29 of 40 patients using protocol B (iliac 40 vs. 37, femoral 40 vs. 40, popliteocrural 35 vs. 37, pedal 16 vs. 29); without the pedal station the number increased to 35 of 40 patients for both protocols. The reason of diagnostic limitations was an arteriovenous overlap in 24 of 80 cases, with 19 of 40 cases for protocol A and 5 of 40 for protocol B, located exclusively in the cruropedal region. Conclusion: Moving table hybrid CEMRA is superior to conventional technique in craniocaudal direction by producing less venous overlap of arteries and is especially more suitable for the diagnostic evaluation of the cruropedal region. (orig.) [de

  5. Coronary angiography using synchrotron radiation

    International Nuclear Information System (INIS)

    Akatsuka, Takao; Hiranaka, Yukio; Takeda, Tohru; Hyodo, Kazuyuki.

    1990-01-01

    Invasive coronary angiography is the imaging technique of choice for diagnosis of ischemic heart disease. Recently, the application of synchrotron radiation in coronary angiography has been investigated in the world, with the aim of developing the noninvasive technique for visualizing the heart. In this article, backgrounds and present situation of coronary angiography using synchrotron radiation are reviewed. Firstly, visual imaging techniques of the cardiovascular system are discussed in terms of angiography and digital subtraction angiography (DSA). Conventional temporal, energy, and hybrid subtraction modes used in DSA are referred to. Secondly, the application of synchrotron radiation is presented, focusing on the property of synchrotron radiation and K-edge subtraction angiography. Two kinds of synchrotron radiation beam methods are outlined. Interpretation of image data and various subtraction procedures remain unestablished. There is much to be done before coronary angiography using synchrotron radiation comes into a clinical practice. (N.K.)

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. Angiography uses ... has narrowed the arteries to the legs and help prepare for endovascular intervention or surgery. detect disease ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you're taking and allergies, especially ... is Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... far outweighs the risk. If you have a history of allergy to x-ray contrast material, your ... Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Interventional radiologist performing an angiography exam View ... ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored by Please note ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... resonance imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an ... The catheter used in angiography is a long plastic tube about as thick as a strand of ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... lies. The catheter used in angiography is a long plastic tube about as thick as a strand of spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... Z Catheter Angiography Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material ... vessels in the body. Angiography is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging ( ...

  13. Benefit of cone-beam computed tomography angiography in acute management of angiographically undetectable ruptured arteriovenous malformations.

    Science.gov (United States)

    Rahal, Jason P; Malek, Adel M

    2013-10-01

    Ruptured arteriovenous malformations (AVMs) are a frequent cause of intracerebral hemorrhage (ICH). In some cases, compression from the associated hematoma in the acute setting can partially or completely occlude an AVM, making it invisible on conventional angiography techniques. The authors report on the successful use of cone-beam CT angiography (CBCT-A) to precisely identify the underlying angioarchitecture of ruptured AVMs that are not visible on conventional angiography. Three patients presented with ICH for which they underwent examination with CBCT-A in addition to digital subtraction angiography and other imaging modalities, including MR angiography and CT angiography. All patients underwent surgical evacuation due to mass effect from the hematoma. Clinical history, imaging studies, and surgical records were reviewed. Hematoma volumes were calculated. In all 3 cases, CBCT-A demonstrated detailed anatomy of an AVM where no lesion or just a suggestion of a draining vein had been seen with other imaging modalities. Magnetic resonance imaging demonstrated enhancement in 1 patient; CT angiography demonstrated a draining vein in 1 patient; 2D digital subtraction angiography and 3D rotational angiography demonstrated a suggestion of a draining vein in 2 cases and no finding in the third. In the 2 patients in whom CBCT-A was performed prior to surgery, the demonstrated AVM was successfully resected without evidence of a residual lesion. In the third patient, CBCT-A allowed precise targeting of the AVM nidus using Gamma Knife radiosurgery. Cone-beam CT angiography should be considered in the evaluation and subsequent treatment of ICH due to ruptured AVMs. In cases in which the associated hematoma compresses the AVM nidus, CBCT-A can have higher sensitivity and anatomical accuracy than traditional angiographic modalities, including digital subtraction angiography.

  14. MR angiography

    International Nuclear Information System (INIS)

    Masaryk, T.J.; Ross, J.S.

    1991-01-01

    This paper reports on preliminary research and recent clinical experience which indicates that MR angiography can play a role in routine scanning by providing useful information regarding the anatomy of the cerebral circulation. Used in conjunction with conventional spin-echo studies it may improve the overall sensitivity and specificity of MRI in a cost-effective fashion. It does not, however, replace conventional arteriography at this time for either extracranial or intracranial disease. The use of intravascular contrast agents with new fast-scan techniques also provides dynamic information regarding tissue perfusion in a fashion analogous to that of xenon CT. While this work is preliminary, and the exact agents and mathematical models have yet to be defined, the ability to perform parenchymal, angiographic, and physiologic imaging at a single setting is potentially very powerful. Clearly, the role of MR flow techniques deserves further investigation into possible technical refinements, so that accuracy relative to other diagnostic studies and impact upon patient management can be assessed in a meaningful way

  15. Pediatric CT angiography

    International Nuclear Information System (INIS)

    Siegel, M.J.

    2005-01-01

    Advances in CT technology are having profound impact on imaging children and have made CT angiography possible even in neonates. Even with the tiny anatomy of neonates, small volumes of contrast material, and small venous access catheters, successful CT angiography can be performed with attention to detail. Meticulous attention to patient preparation, the proper selection of technical factors, and optimal delivery of contrast material are crucial. Data post-processing and the creation of 3-D reconstructions are also essential in establishing a correct diagnosis. The applications fo CT angiography are different in children than in adults and most applications in children involve assessment of congenital and postoperative vascular and cardiac diseases. The use of CT angiography offers the opportunity to eliminate the long periods of sedation associated with MR and reduce the radiation exposure associated with conventional angiography. Generally, the benefits of CT angiography in children outweigh the risk, namely that of radiation exposure. However, care must still be taken to minimize the radiation exposure. (orig.)

  16. Intraarterial digital subtraction angiography applied to diagnosis of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, Sadahiko; Sano, Akira; Imanaka, Kazufumi; Sasai, Keisuke; Nagae, Toshiyuki; Mizutani, Masaru; Hatabu, Hiroto; Sadatou, Norihiro; Kuroda, Yasumasa

    1985-12-01

    This paper deals with diagnostic values of intraarterial digital subtraction angiography (IADSA) for evaluating hepatocellular carcinoma. The present series consists of 44 patients with hepatocellular carcinoma, who underwent IADSA combined with conventional hepatic angiography 67 times in total. The evaluated vessels by IADSA included 70 hepatic arteries and 36 portal veins. Comparative studies on the image quality of IADSA with conventional angiography were made in referring to the tumor stain for arteriograms and resolution of intrahepatic portal branches for portograms. Diagnostic superiority including equality of DSA image to conventional was noted in arteriograms: 72.7 % in the right lobe and 86 % in the left. Most deteriorated DSA images were caused by misregistration artifacts. IADSA portography revealed basically diagnostic values to demonstrate lobar, segmental or more peripheral branches in about 95 % of cases studied. DSA, characterized by high contrast resolution and real-time subtraction, offered important and effective informations for interventional angiography as well as resectability of the tumors, requiring less contrast medium.

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... medical test that helps physicians diagnose and treat medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ...

  18. Magnetic resonance angiography of arteriovenous malformation in the brainstem

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Hirofumi; Kida, Yoshihisa; Kobayashi, Tatsuya; Tanaka, Takayuki; Iwakoshi, Takayasu; Kai, Osamu; Hirose, Mitsuhiko [Komaki City Hospital, Aichi (Japan)

    1993-11-01

    The magnetic resonance (MR) angiography appearance of arteriovenous malformation (AVM) in the tegmentum and pons is described. The interpeduncular perforating branches of the posterior cerebral artery and median pontine branches of the basilar artery were seen more clearly by MR angiography than by conventional angiography. MR angiography was very useful for the follow-up of AVM after stereotactic radiosurgery. (author).

  19. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... further information please consult the ACR Manual on Contrast Media and its references. The risk of serious allergic ... View full size with caption Related Articles and Media Angioplasty and Vascular Stenting MR Angiography (MRA) Contrast Materials CT Angiography (CTA) X-ray, Interventional Radiology ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. ...

  2. Dynamic contrast-enhanced subtraction MR angiography in intracranial vascular abnormalities

    International Nuclear Information System (INIS)

    Takano, K.; Ono, H.; Utsunomiya, H.; Okazaki, M.; Tanaka, A.

    1999-01-01

    We present our clinical experience with dynamic contrast-enhanced MR angiography (MRA) with subtraction for assessing intracranial vascular abnormalities. Ten patients with various cerebrovascular disorders underwent dynamic contrast-enhanced MRA on a 1.0-T system. Thirty sections (2 mm) were acquired in 29-30 s. Maximum intensity projection images and subtracted source images were compared with those obtained by conventional angiography. In all cases, the presence or absence of abnormalities in the targeted vessels, as well as the morphology of the sagittal sinuses, was clearly visualized as in conventional angiography, without any obstructions such as hyperintense hematomas or thrombi, or intraluminal turbulence. Although the temporal and spatial resolutions with current hardware are insufficient, these preliminary results suggest that dynamic contrast-enhanced MRA with subtraction may be useful for assessing vascular lesions with hemorrhage or thrombus, and the dural sinuses. (orig.)

  3. Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model

    International Nuclear Information System (INIS)

    Struffert, Tobias; Ott, Sabine; Adamek, Edyta; Schwarz, Marc; Engelhorn, Tobias; Kloska, Stephan; Doerfler, Arnd; Deuerling-Zheng, Yu

    2011-01-01

    Careful follow up is necessary after intracranial stenting because in-stent restenosis (ISR) or residual stenosis (RS) is not rare. A minimally invasive follow-up imaging technique is desirable. The objective was to compare the visualisation of stents in Flat Detector-CT Angiography (FD-CTA) after intravenous contrast medium injection (i.v.) with Multi Detector Computed Tomography Angiography (MD-CTA) and Digital Subtracted Angiography (DSA) in an animal model. Stents were implanted in the carotid artery of 12 rabbits. In 6 a residual stenosis (RS) was surgically created. Imaging was performed using FD-CTA, MD-CTA and DSA. Measurements of the inner and outer diameter and cross-section area of the stents were performed. Stenosis grade was calculated. In subjective evaluation FD-CTA was superior to MD-CTA. FD-CTA was more accurate compared with DSA than MD-CTA. Cross-sectional area of the stent lumen was significantly larger (p < 0.05) in FD-CTA in comparison to MD-CTA. Accurate evaluation of stenosis was impossible in MD-CTA. There was no statistically significant difference in the stenosis grade of DSA and FD-CTA. Our results show that visualisation of stent and stenosis using intravenous FD-CTA compares favourably with DSA and may replace DSA in the follow-up of patients treated with intracranial stents. (orig.)

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... to your primary care or referring physician , who will discuss the results with you. top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... Contrast Materials CT Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... diagnosis and treatment in a single procedure. An example is finding an area of severe arterial narrowing, ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... possible to combine diagnosis and treatment in a single procedure. Catheter angiography produces very detailed, clear and ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... a tendency to bleed. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an artery ... examined, a contrast material is injected through the tube and images are captured using a small dose ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... angiogram may be performed in less than an hour; however, it may last several hours. top of ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... accurate pictures of the blood vessels and may eliminate the need for surgery. Tell your doctor if ... are the benefits vs. risks? Benefits Angiography may eliminate the need for surgery. If surgery remains necessary, ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... possible charges you will incur. Web page review process: This Web page is reviewed regularly by a ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... congenital abnormalities in blood vessels, especially arteries in children (e.g., malformations in the heart or other ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... far outweighs the risk. If you have a history of allergy to x-ray contrast material, your ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... and x-rays. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. Catheter angiography ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. An example ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... blood flow to the brain and cause a stroke. identify a small aneurysm or arteriovenous malformation (abnormal ... you. top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need for ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... iodine. If angiography is essential, a variety of methods is used to decrease risk of allergy: You ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... few millimeters) in the skin where the catheter can be inserted into an artery. The catheter is ... need for surgery. If surgery remains necessary, it can be performed more accurately. Catheter angiography presents a ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... examine blood vessels in key areas of the body for abnormalities such as aneurysms and disease such ... to produce pictures of blood vessels in the body. Angiography is performed using: x-rays with catheters ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... 20 minutes (or by using a special closure device). When the examination is complete, you may be ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material to examine ... removable dental appliances, eye glasses and any metal objects or clothing that might interfere with the x- ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... rays ). top of page What are some common uses of the procedure? Catheter angiography is used to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... American College of Radiology (ACR) and the European Society of Urogenital Radiology note that the available data ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... with you. top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need for surgery. If ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need for surgery. ... in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... most cases, the kidneys will regain their normal function within five to seven days. Rarely, the catheter ... limitations of Catheter Angiography? Patients with impaired kidney function, especially those who also have diabetes, are not ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... in key areas of the body, including the: brain neck heart chest abdomen (such as the kidneys ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... The video is produced by the x-ray machine and a detector that is suspended over a ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... serious allergic reaction to contrast materials that contain iodine is extremely rare, and radiology departments are well- ... having a reaction to contrast materials that contain iodine. If angiography is essential, a variety of methods ...

  14. Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: Comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Pozzi-Mucelli, Fabio; Bruni, Stefano; Doddi, Marco; Calgaro, Antonio; Braini, Massimiliano; Cova, Maria

    2007-01-01

    Purpose: To compare the contribution of 64 channel multidetector row computed tomography angiography (64MDCT-angiography) with digital subtraction angiography (DSA) in the detection of intracranial aneurysms. Methods and materials: Twenty-nine patients (10 males and 19 females, age: 40-84 years; average: 61.9 years) with clinical and imaging findings strongly suggesting the presence of subaracnoid hemorrhage underwent 64MDCT-angiography and DSA with a short interval between the two examinations (less than 12 h-5 days). CT parameters were: 64 mm x 0.5 mm collimation, pitch-0.828 and helical pitch-53. DSA were performed with standard technique (four vessel catheterization) and multiple projections. Axial CT scans as well as maximum intensity projection, volume rendering and multiplanar reformations and angiographic views were independently reviewed by four readers (two for 64MDCT-angiography and two for DSA). Consensus was reached for discordant cases. DSA was considered as the standard of reference. Results: In 29 patients, 28 aneurysms were found (14 patients had 1 aneurysm, 4 patients had 2 aneurysms and 2 patients had 3 aneurysms; in 9 patients no aneurysm were found). 64MDCT-angiography detected 26/28 aneurysms. No false-positive sites were recognized. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 92.8, 100, 100, 99.4 and 99.5%. Conclusions: 64MDCT-angiography is helpful in detecting intracranial aneurysms with results similar to those of DSA but with less discomfort and risks for the patients and can be considered for the first line imaging technique. Conventional angiography is still needed in doubtful cases or negative MDCT-angiography associated with a strong clinical suspect

  15. CT coronary angiography vs. invasive coronary angiography in CHD

    Directory of Open Access Journals (Sweden)

    Anja Hagen

    2012-04-01

    Full Text Available Scientific background: Various diagnostic tests including conventional invasive coronary angiography and non-invasive computed tomography (CT coronary angiography are used in the diagnosis of coronary heart disease (CHD. Research questions: The present report aims to evaluate the clinical efficacy, diagnostic accuracy, prognostic value cost-effectiveness as well as the ethical, social and legal implications of CT coronary angiography versus invasive coronary angiography in the diagnosis of CHD. Methods: A systematic literature search was conducted in electronic data bases (MEDLINE, EMBASE etc. in October 2010 and was completed with a manual search. The literature search was restricted to articles published from 2006 in German or English. Two independent reviewers were involved in the selection of the relevant publications. The medical evaluation was based on systematic reviews of diagnostic studies with invasive coronary angiography as the reference standard and on diagnostic studies with intracoronary pressure measurement as the reference standard. Study results were combined in a meta-analysis with 95 % confidence intervals (CI. Additionally, data on radiation doses from current non-systematic reviews were taken into account. A health economic evaluation was performed by modelling from the social perspective with clinical assumptions derived from the meta-analysis and economic assumptions derived from contemporary German sources. Data on special indications (bypass or in-stent-restenosis were not included in the evaluation. Only data obtained using CT scanners with at least 64 slices were considered. Results: No studies were found regarding the clinical efficacy or prognostic value of CT coronary angiography versus conventional invasive coronary angiography in the diagnosis of CHD. Overall, 15 systematic reviews with data from 44 diagnostic studies using invasive coronary angiography as the reference standard (identification of obstructive

  16. Three-Dimensional Respiratory-Gated Coronary Mr Angiography with Reference to X-Ray Coronary Angiography

    International Nuclear Information System (INIS)

    Ikonen, A. E. J.; Manninen, H. I.; Vainio, P.; Vanninen, R. L.; Matsi, P. J.; Soimakallio, S.; Hirvonen, T.P.J.; Hartikainen, J.E.K.

    2003-01-01

    Purpose: To assess the clinical value of three-dimensional coronary MR angiography (CMRA) in the detection of significant coronary artery stenosis using conventional X-ray angiography as the standard reference. Material and Methods: Sixty-nine patients underwent X-ray coronary angiography and CMRA because of suspected or previously diagnosed coronary artery disease. MRI was performed with a 1.5-T whole body imaging system using ECG-triggered 3D gradient echo sequence with retrospective navigator echo respiratory gating and fat suppression. Results: A total of 276 coronary artery segments were analyzed. The X-ray coronary angiography was normal in 22 patients. Significant proximal stenoses (exceeding 50%) or occlusions were present in 102 coronary artery segments. In all, 120 stenoses or occlusions were identified in CMRA. Sixteen percent of the coronary artery segments had to be excluded because of poor image quality. The overall sensitivity and specificity for MRA for identification of significant stenosis were 75% and 62%, respectively. CMRA correctly detected 89% of patients with at least one vessel disease, but 6 patients with coronary artery disease would have been missed. Conclusions: Because of the high data exclusion and false-negative case rate, CMRA with retrospective navigator echo triggering is at present not suitable as a clinical screening method in coronary artery disease

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... rare, and radiology departments are well-equipped to deal with them. There is a small risk that ... standard x-ray contrast. Catheter angiography should be done very cautiously—if at all—in patients who ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ... about radiology? Share your patient story here Images × ... Related Articles and Media Angioplasty and Vascular Stenting MR Angiography (MRA) Contrast ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... the equipment look like? How does the procedure work? How is the ... and treat medical conditions. Angiography uses one of three imaging technologies and, ...

  20. Is fasting necessary for elective cerebral angiography?

    Science.gov (United States)

    Kwon, O-K; Oh, C W; Park, H; Bang, J S; Bae, H-J; Han, M K; Park, S-H; Han, M H; Kang, H-S; Park, S-K; Whang, G; Kim, B-C; Jin, S-C

    2011-05-01

    In order to prevent unexpected events such as aspiration pneumonia, cerebral angiography has been performed under fasting in most cases. We investigated prospectively the necessity of fasting before elective cerebral angiography. The study is an open-labeled clinical trial without random allocation. In total, 2554 patients who underwent elective cerebral angiography were evaluated on development of nausea, vomiting, and pulmonary aspiration during and after angiography. Potential risks and benefits associated with fasting were provided in written documents and through personal counseling to patients before the procedure. The patients chose their fasting or nonfasting option. No restriction in diet was given after angiography. The patients were observed for 24 hours. Nausea and vomiting during and within 1 hour after angiography was considered as a positive event associated with cerebral angiography. The overall incidence of nausea and vomiting during and within 1 hour after angiography was 1.05% (27/2554 patients). There was no patient with pulmonary aspiration. No statistical difference in nausea and vomiting development between the fasting and the diet groups was found. The incidence of nausea and vomiting associated with cerebral angiography is low and not affected by diet or fasting. Pulmonary aspiration had no difference between the diet and the fasting group. Our study suggests that fasting may not be necessary for patients who undergo elective cerebral angiography.

  1. Digital angiography in pulmonary embolism

    International Nuclear Information System (INIS)

    Bjoerk, L.

    1986-01-01

    Pulmonary digital subtraction angiography was diagnostic in 98.3% of patients with possible acute pulmonary embolism. The procedure was well tolerated even in severely ill patients. A large image intensifier made simultaneous imaging of both lungs possible reducing the number of contrast injections necessary. Small volumes of low iso-osmolar concentration of modern contrast media were used. There was no need for catherization of the pulmonary artery. Theoretical considerations and our limited experience indicate that this will reduce the number of complications compared with conventional pulmonary angiography. The procedure is rapidly performed and the diagnostic accuracy high. This makes digital subtraction angiography cost effective. Digital pulmonary angiography can be recommended as the primary diagnostic method in most patients with possible pulmonary embolism. (orig.)

  2. Nonvariceal Upper Gastrointestinal Bleeding: the Usefulness of Rotational Angiography after Endoscopic Marking with a Metallic Clip

    Energy Technology Data Exchange (ETDEWEB)

    Song, Ji Soo; Kwak, Hyo Sung; Chung, Gyung Ho [Chonbuk National University Medical School, Chonju (Korea, Republic of)

    2011-08-15

    We wanted to assess the usefulness of rotational angiography after endoscopic marking with a metallic clip in upper gastrointestinal bleeding patients with no extravasation of contrast medium on conventional angiography. In 16 patients (mean age, 59.4 years) with acute bleeding ulcers (13 gastric ulcers, 2 duodenal ulcers, 1 malignant ulcer), a metallic clip was placed via gastroscopy and this had been preceded by routine endoscopic treatment. The metallic clip was placed in the fibrous edge of the ulcer adjacent to the bleeding point. All patients had negative results from their angiographic studies. To localize the bleeding focus, rotational angiography and high pressure angiography as close as possible to the clip were used. Of the 16 patients, seven (44%) had positive results after high pressure angiography as close as possible to the clip and they underwent transcatheter arterial embolization (TAE) with microcoils. Nine patients without extravasation of contrast medium underwent TAE with microcoils as close as possible to the clip. The bleeding was stopped initially in all patients after treatment of the feeding artery. Two patients experienced a repeat episode of bleeding two days later. Of the two patients, one had subtle oozing from the ulcer margin and that patient underwent endoscopic treatment. One patient with malignant ulcer died due to disseminated intravascular coagulation one month after embolization. Complete clinical success was achieved in 14 of 16 (88%) patients. Delayed bleeding or major/minor complications were not noted. Rotational angiography after marking with a metallic clip helps to localize accurately the bleeding focus and thus to embolize the vessel correctly.

  3. Nonvariceal Upper Gastrointestinal Bleeding: the Usefulness of Rotational Angiography after Endoscopic Marking with a Metallic Clip

    International Nuclear Information System (INIS)

    Song, Ji Soo; Kwak, Hyo Sung; Chung, Gyung Ho

    2011-01-01

    We wanted to assess the usefulness of rotational angiography after endoscopic marking with a metallic clip in upper gastrointestinal bleeding patients with no extravasation of contrast medium on conventional angiography. In 16 patients (mean age, 59.4 years) with acute bleeding ulcers (13 gastric ulcers, 2 duodenal ulcers, 1 malignant ulcer), a metallic clip was placed via gastroscopy and this had been preceded by routine endoscopic treatment. The metallic clip was placed in the fibrous edge of the ulcer adjacent to the bleeding point. All patients had negative results from their angiographic studies. To localize the bleeding focus, rotational angiography and high pressure angiography as close as possible to the clip were used. Of the 16 patients, seven (44%) had positive results after high pressure angiography as close as possible to the clip and they underwent transcatheter arterial embolization (TAE) with microcoils. Nine patients without extravasation of contrast medium underwent TAE with microcoils as close as possible to the clip. The bleeding was stopped initially in all patients after treatment of the feeding artery. Two patients experienced a repeat episode of bleeding two days later. Of the two patients, one had subtle oozing from the ulcer margin and that patient underwent endoscopic treatment. One patient with malignant ulcer died due to disseminated intravascular coagulation one month after embolization. Complete clinical success was achieved in 14 of 16 (88%) patients. Delayed bleeding or major/minor complications were not noted. Rotational angiography after marking with a metallic clip helps to localize accurately the bleeding focus and thus to embolize the vessel correctly.

  4. Digital subtraction angiography in ischemic cerebrovascular accidents

    Energy Technology Data Exchange (ETDEWEB)

    Manelfe, C.; Bonafe, A.; Ducos de Lahitte, M.; Rascol, A.; Prere, J.; Guiraud, B.; Marc-Vergnes, J.P. (Hopital Purpan, 31 - Toulouse (France))

    1983-12-29

    Recent advances in computer and radiological technology have permitted reassessment of intravenous angiography in the evaluation of cerebrovascular disorders. Although digital subtraction angiography is a relatively new technique, it has rapidly gained a widespread acceptance. It has extended the use of angiography to outpatients and to people in whom conventional angiography is contraindicated. This reliable, safe, and relatively noninvasive technique offers the user two benefits: real-time subtraction and enhanced image quality. The system allows angiographic evaluation of the extracranial and intracranial vessels by means of intravenous injection of contrast material. Extracranial studies clearly demonstrate stenoses and occlusions of the major cervicocephalic arteries. Intracranial studies usually detect major cerebrovascular occlusions and provide insight into the collateral flow patterns. Intravenous digital subtraction angiography permits accurate assessment of cervicocephalic vessels after surgical repair. Although intravenous digital subtraction angiography obviates the need for conventional angiography in many cases, movements from the patients, or superimposition of vascular structures can substantially degrade the quality of the images. Digital subtraction angiography with intra-arterial injection of contrast medium will be contemplated in patients with poor intravenous digital subtraction angiography studies prior to surgery.

  5. Digital subtraction angiography in ischemic cerebrovascular accidents

    International Nuclear Information System (INIS)

    Manelfe, C.; Bonafe, A.; Ducos de Lahitte, M.; Rascol, A.; Prere, J.; Guiraud, B.; Marc-Vergnes, J.P.

    1983-01-01

    Recent advances in computer and radiological technology have permitted reassessment of intravenous angiography in the evaluation of cerebrovascular disorders. Although digital subtraction angiography is a relatively new technique, it has rapidly gained a widespread acceptance. It has extended the use of angiography to outpatients and to people in whom conventional angiography is contraindicated. This reliable, safe, and relatively noninvasive technique offers the user two benefits: real-time subtraction and enhanced image quality. The system allows angiographic evaluation of the extracranial and intracranial vessels by means of intravenous injection of contrast material. Extracranial studies clearly demonstrate stenoses and occlusions of the major cervicocephalic arteries. Intracranial studies usually detect major cerebrovascular occlusions and provide insight into the collateral flow patterns. Intravenous digital subtraction angiography permits accurate assessment of cervicocephalic vessels after surgical repair. Although intravenous digital subtraction angiography obviates the need for conventional angiography in many cases, movements from the patients, or superimposition of vascular structures can substantially degrade the quality of the images. Digital subtraction angiography with intra-arterial injection of contrast medium will be contemplated in patients with poor intravenous digital subtraction angiography studies prior to surgery [fr

  6. Diagnostic and interventional angiography of superior mesenteric artery

    Energy Technology Data Exchange (ETDEWEB)

    Simonetti, G; Urigo, F; Canalis, G C; Guazzaroni, M; Caboni, M; Rossi, P; Passariello, R

    1986-01-01

    The widespread diffusion of digital imaging progressivaly reduces the indications to conventional angiography in all vascular districts. On the contrary, angiography of mesenteric arteries still works as a valid complementary diagnostic tool in granulomatous and neoplastic lesions of ileum. Today, in selected patients, angiography is the first diagnostic approach to vascular ischemic and hemorrhagic pathology of ileum; timely resort to interventional angiography improve a dramatic prognosis. 70 refs.

  7. Angiografía del día siguiente tras fibrinólisis exitosa frente al tratamiento convencional, en el síndrome coronario agudo con elevación del segmento ST, fibrinolisado Angiography performed the next day after successful thrombolysis versus conventional treatment in acute coronary syndrome with ST segment elevation

    Directory of Open Access Journals (Sweden)

    José D Cascón-Pérez

    2012-01-01

    % underwent a conventional strategy with a provocation test to elicit ischemia (conventional treatment. Results: In the first group, the average stay was 7.3 ± 3 days [median interquartile range: 7 (5-8]. The incidence of fatal events per year was 3 (4%. There were no major bleeding, only 20 of them (22% had groin hematomas larger than 2 cm. In the second group, the average stay was 10.2 ± 6.3 days [9 (6-13], significantly higher (p <0.001. The number of fatal events per year was 7 (11% and no statistically significant differences were observed (p = 0.52. Conclusions: Angiography performed the next day is associated with reduced length of stay compared to conventional treatment. It also seems to show a trend (not significant of reduction in year mortality without increasing the number of bleeding complications.

  8. Magnetic resonance angiography vs. angiography in tetralogy of Fallot.

    Science.gov (United States)

    Rao, Uppalapati Venkateswara; Vanajakshamma, Velam; Rajasekhar, Durgaprasad; Lakshmi, Amancharla Yadagiri; Reddy, Reddivari Niranjan

    2013-08-01

    : To determine whether gadolinium-enhanced three-dimensional magnetic resonance angiography can provide a noninvasive alternative to diagnostic catheterization for evaluation of pulmonary artery anatomy in tetralogy of Fallot. Thirty-five consecutive patients with tetralogy of Fallot, who attended the cardiology outpatient department between January 2008 and December 2009, were included in the study. There were 21 males and 14 females, with a mean age of 9 ± 4.15 years (range, 3-21 years). Thirty-two patients had tetralogy of Fallot with varying severities of valvular and infundibular stenosis. Three patients had tetralogy of Fallot with pulmonary atresia. All patients underwent both cardiac catheterization with X-ray angiography and 3-dimensional magnetic resonance angiography within one month. Measurements of right and left pulmonary arteries and aortopulmonary collaterals were equal by both methods. There was a good correlation between magnetic resonance angiography and catheterization measurements of branch pulmonary arteries. Gadolinium-enhanced three-dimensional magnetic resonance angiography can be used as a reliable noninvasive alternative to X-ray cineangiography for delineation of pulmonary arterial anatomy in sick infants and young children, obviating the need for catheterization.

  9. Intraarterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Davis, P.C.

    1987-01-01

    Digital subtraction angiography (DSA) refers to a radiographic technique of amplifying low levels of contrast from intravascular iodine into an acceptable image of vascular anatomy. Initial enthusiasm suggested that DSA using intravenous injections (IV-DSA) would eliminate most conventional film-screen angiographic studies. It was soon apparent, however, that IV-DSA examinations were often compromised in those patients who most needed a less invasive study. Indeed, only a 70 to 85 percent accuracy rate was achieved with IV-DSA, primarily due to motion artifact, poor cardiac output, overlap of pertinent vessels, and inability to resolve smaller vessels

  10. Cone-Beam CT Angiography for Determination of Tumor-Feeding Vessels During Chemoembolization of Liver Tumors: Comparison of Conventional and Dedicated-Software Analysis.

    Science.gov (United States)

    Ronot, Maxime; Abdel-Rehim, Mohamed; Hakimé, Antoine; Kuoch, Viseth; Roux, Marion; Chiaradia, Mélanie; Vilgrain, Valérie; de Baere, Thierry; Deschamps, Frédéric

    2016-01-01

    To compare the ability of dedicated software and conventional cone-beam computed tomography (CT) analysis to identify tumor-feeding vessels in hypervascular liver tumors treated with chemoembolization. Between January 2012 and January 2013, 45 patients (32 men, mean age of 61 y; range, 27-85 y) were enrolled, and 66 tumors were treated (mean, 32 mm ± 18; range, 10-81 mm) with conventional chemoembolization with arterial cone-beam CT. Data were independently analyzed by six interventional radiologists with standard postprocessing software, a computer-aided analysis with FlightPlan for liver (FPFL; ie, "raw FPFL"), and a review of this computer-aided FPFL analysis ("reviewed FPFL"). Analyses were compared with a reference reading established by two study supervisors in consensus who had access to all imaging data. Sensitivities, positive predictive values (PPVs), and false-positive (FP) ratios were compared by McNemar, χ(2), and Fisher exact tests. Analysis durations were compared by Mann-Whitney test, and interreader agreement was assessed. Reference reading identified 179 feeder vessels. The sensitivity of raw FPFL was significantly higher than those of reviewed FPFL and conventional analyses (90.9% vs 83.2% and 82.1%; P software enabled a fast, accurate, and sensitive detection of tumor feeder vessels. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  11. Contrast-Enhanced MR Angiography (CEMRA) in Peripheral Arterial Occlusive Disease (PAOD): conventional moving table technique versus hybrid technique; Kontrastverstaerkte MR-Angiographie (CEMRA) bei peripherer AVK (pAVK): konventionelle Tischverschiebetechnik versus Hybrid-Technik

    Energy Technology Data Exchange (ETDEWEB)

    Kalle, T. von; Gerlach, A.; Hatopp, A.; Klinger, S.; Prodehl, P.; Arlat, I.P. [Katharinenhospital, Stuttgart (Germany). Radiologisches Inst.

    2004-01-01

    Patients and Methods: 80 patients (males n = 60, females n = 20, median age = 70 years, diabetics n = 27) with PAOD were examined with a 1,5T system (40 mT/m) using a dedicated phased array peripheral vascular coil. Protocol A consisted of a single injection of Gd-BOPTA with consecutive craniocaudal image acquisition and protocol B of two injections, with the first injection of Gd-BOPTA followed by image acquisition of the popliteocrural and pedal segments and the second injection followed by acquiring the aortoiliac and femoral segments (hybrid technique). The evaluation of the arterial system was directed to the iliac, femoral, popliteocrural and pedal arteries. Results: The visualization of the entire aortopedal vascular system was of diagnostically good or satisfactory quality in 16 of 40 patients using protocol A and in 29 of 40 patients using protocol B (iliac 40 vs. 37, femoral 40 vs. 40, popliteocrural 35 vs. 37, pedal 16 vs. 29); without the pedal station the number increased to 35 of 40 patients for both protocols. The reason of diagnostic limitations was an arteriovenous overlap in 24 of 80 cases, with 19 of 40 cases for protocol A and 5 of 40 for protocol B, located exclusively in the cruropedal region. Conclusion: Moving table hybrid CEMRA is superior to conventional technique in craniocaudal direction by producing less venous overlap of arteries and is especially more suitable for the diagnostic evaluation of the cruropedal region. (orig.) [German] Patienten und Methodik: Untersucht wurden 80 Patienten (maennl. n = 60, weibl. n = 20, mittl. Alter 70 J., Diabetiker n = 27) mit pAVK an einem 1,5-Tesla-Geraet (40 mT/m) mit dedizierter Phased-Array-Oberflaechen-Gefaessspule. Protokoll A beinhaltete eine Kontrastmittel-Injektion (Gd-BOPTA) mit konsekutiver kraniokaudaler Bildakquisition. In Protokoll B erfolgte die Akquisition zunaechst der Unterschenkel- und Fussetage mittels einer ersten, anschliessend der Abdomen-Becken- und Oberschenkeletage mittels

  12. Pediatric angiography

    International Nuclear Information System (INIS)

    Fitz, A.R.

    1987-01-01

    Angiography of the cerebral and visceral arterial systems is performed much less frequently than it was before the advent of computed tomographic scanning (CT). Most institutions have experienced at least a 50% reduction in the number of angiograms performed since installing a CT scanner. However, angiography still plays an important role in the confirmation of diagnoses made using a scanner, and in providing valuable information to the surgeon prior to excision of tumors or the repair of traumatized organs. Recently a number of sophisticated therapeutic procedures requiring vascular catheterization and the injection of contrast agents have been developed. In these procedures catheters are selectively placed in blood vessels perfusing a pathological process, such as an arteriovenous malformation, or at the site of an arterial stenosis; embolization of the arteriovenous malformation or tumor, or dilatation of the stenotic segment, is then performed. Whether the vessel catheterization is for diagnostic or therapeutic purposes, the basic approach is the same, and the technologist's duties are similar. The principal difference between a diagnostic and a therapeutic procedure is the length of time required to carry out the study; therapeutic procedures often require significantly longer periods of general anesthesia or sedation than do diagnostic studies

  13. Pulmonary angiography with lopamidol 370

    International Nuclear Information System (INIS)

    Braun, S.D.; Saeed, M.; Perlmutt, L.M.; Newman, G.E.; Illescas, F.F.; Cohan, R.H.; Dunnick, N.R.

    1986-01-01

    Fifty-one consecutive patients who underwent pulmonary angiography with iopamidol, 370 mg/ml, were studied prospectively. Patients were asked to grade any heat or pain felt on injection, and were observed for coughing. Right atrial and pulmonary artery pressures were obtained before the first and after the final contrast agent injection. Pressure changes were compared with those in a consecutive group of 25 patients who underwent examinations performed with Na-meglumine diatrizoate, 370 mg/ml. Film quality was evaluated for patient motion. Iopamidol generated marked discomfort in only three patients. Pressure changes were largely unremarkable. In no case was there any significant motion artifact secondary to coughing. Iopamidol is a safe, well-tolerated contrast agent for pulmonary angiography. It improves image quality by nearly eliminating coughing

  14. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...

  15. MRI angiography

    International Nuclear Information System (INIS)

    Poncelet, B.; Baleriiaux, D.; struyven, J.; Segebarth, C.

    1989-01-01

    In MRI angiography two basis images are measured which only differ by the signal intensity of the flowing blood in the vessels. Subtraction of these two images produces a high contrast-to-noise representation of the vessels. Contrast between stationary tissues and flowing blood is changed, for one image compared to the second one, using a selective modification of the phase of the signal from the flowing blood, and/or using a selective modification of its longitudinal magnetization: The macroscopic spin motions along the selection and the measurement gradient directions affect the phase of the nuclear signal; assuming constant velocity, the phase is proportional to the velocity and to the first moment of the gradient waveforms applied. This work concentrates on the generarion of MRI angiograms, following a phase-based approach, of the carotid bifurcation and of different intracranical regions including the carotid syphon and the circle of Willis. (author). 21 refs.; 3 figs

  16. Radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Heidenreich, P; Klotz, E

    1983-12-27

    RNA of common and internal carotid arteries as well as main cerebral arteries is the first component of cerebral serial scintigraphy. It should be the first diagnostic step in suspected cerebrovascular disease. In contrast to computed tomography RNA gives valuable information about cerebrovascular processes without morphological defects. RNA is superior of Doppler sonography in the evaluation of intracranial vascular disease. The simple and non-invasive RNA of the kidneys should be performed after renal transplantation (i.e. differential diagnosis of acute rejection and acute tubular necrosis), in suspected renal artery stenosis, renal infarction or in arterio-venous malformation of the kidneys. RNA is valuable in suspected occlusion of the abdominal aorta (infra- or suprarenal), aortic aneurysm or in stenosis of arteries in the pelvis or thighs. Postoperative controls can be carried out as often as desired. However, it cannot replace contrast angiography if vascular reconstruction is planned.

  17. Three-dimensional magnetic resonance angiography of vascular lesions in children.

    Science.gov (United States)

    Katayama, H; Shimizu, T; Tanaka, Y; Narabayashi, I; Tamai, H

    2000-01-01

    We applied three-dimensional (3D) magnetic resonance (MR) angiography to vascular lesions in children and evaluated the clinical usefulness of this technique. Ten patients, whose ages ranged from 1 month to 16 years, underwent 3D MR angiography for 12 vascular lesions, including lesions in seven pulmonary arteries, two thoracic aortae, a pair of renal arteries, and one iliac artery. Three-dimensional MR angiography was performed with body-or pelvic-phased array coils on a 1.5-T scanner using fast spoiled gradient echo sequence. Data were acquired with the following parameters: TE, 1.9 ms; TR, 10.1 ms; flip angle, 20-60 degrees ; 1 or 2 NEX; field of view, 24-48 x 18-40 cm; matrix, 256 or 512 x 128 or 256; slice thickness, 1.2-7.5 mm; and 12, 28, or 60 partitions. Vascular imaging was enhanced with 20% gadolinium-diethylenetriaminepentaacetic acid. The examination was performed under breath-holding in six patients and with shallow breathing in four patients. In a comparative study with other noninvasive methods, 3D MR angiography was superior in seven of nine cases to other noninvasive examinations and in two cases, all methods evaluated the lesions. Furthermore, six cases were compared with conventional angiography. In five of the six cases, both methods depicted the lesions similarly, and in one case, MR angiography was more effective. A quantitative comparison of vascular diameter in the MR image was made with that in the conventional angiographic image. The correlation between them was excellent: y = 1.145x-2.090 (r = 0.987; P children.

  18. Preoperative evaluation of the artery of adamkiewicz by MR angiography and CT angiography in patients with a thoracic aortic aneurysm

    International Nuclear Information System (INIS)

    Niinuma, Hiroyuki; Ohira, Atsushi; Makita, Shinji; Moriai, Yoshiteru; Hiramori, Katsuhiko; Yoshioka, Kunihiro; Nakajima, Takayuki; Kawazoe, Kohei

    2002-01-01

    Paraplegia is known as an extremely serious and important complication of surgical repair in patients with a thoraco-abdominal aortic aneurysm. It is important to evaluate the artery of Adamkiewicz (AdA) before surgical repair to prevent paraplegia. But the AdA is difficult to visualize by the invasive and hazardous, conventional selective angiography. The aim of this study was to visualize AdA by MR angiography (MRA) and CT angiography (CTA). Twenty-one consecutive patients with a thoracic aortic aneurysm underwent both gadolinium-enhanced, three-dimensional MRA and CTA using multislice helical CT. The AdA was successfully visualized in 15 of the 21 patients (71.4%) by MRA, and in 17 of those 21 patients (80.9%) by CTA. Its continuity was depicted in 12 of 15 patients (80%) by MRA, and in 9 of 17 patients (47%) by CTA. AdA was visualized at 85.7% by MRA or CTA, respectively. This study shows that CTA is a much more sensitive method to detect AdA than MRA. On the other hand, MRA is better to evaluate the continuity of AdA from the descending aorta to the anterior spinal artery, than CTA. Therefore, MRA and CTA are both useful for a preoperative evaluation of AdA and its detailed vascular anatomy from the aorta to the anterior spinal artery. (author)

  19. The increased use of computed tomography angiography and magnetic resonance angiography as the sole imaging modalities prior to infrainguinal bypass has had no effect on outcomes.

    Science.gov (United States)

    Shue, Bing; Damle, Rachelle N; Flahive, Julie; Kalish, Jeffrey A; Stone, David H; Patel, Virendra I; Schanzer, Andres; Baril, Donald T

    2015-08-01

    Angiography remains the gold standard imaging modality before infrainguinal bypass. Computed tomography angiography (CTA) and magnetic resonance angiography (MRA) have emerged as noninvasive alternatives for preoperative imaging. We sought to examine contemporary trends in the utilization of CTA and MRA as isolated imaging modalities before infrainguinal bypass and to compare outcomes following infrainguinal bypass in patients who underwent CTA or MRA versus those who underwent conventional arteriography. Patients undergoing infrainguinal bypass within the Vascular Study Group of New England were identified (2003-2012). Patients were stratified by preoperative imaging modality: CTA/MRA alone or conventional angiography. Trends in utilization of these modalities were examined and demographics of these groups were compared. Primary end points included primary patency, secondary patency, and major adverse limb events (MALE) at 1 year as determined by Kaplan-Meier analysis. Multivariable Cox proportional hazards models were constructed to evaluate the effect of imaging modality on primary patency, secondary patency, and MALE after adjusting for confounders. In 3123 infrainguinal bypasses, CTA/MRA alone was used in 462 cases (15%) and angiography was used in 2661 cases (85%). Use of CTA/MRA alone increased over time, with 52 (11%) bypasses performed between 2003 and 2005, 189 (41%) bypasses performed between 2006 and 2009, and 221 (48%) bypasses performed between 2010 and 2012 (P < 0.001). Patients with CTA/MRA alone, compared with patients with angiography, more frequently underwent bypass for claudication (33% vs. 26%, P = 0.001) or acute limb ischemia (13% vs. 5%, P < 0.0001), more frequently had prosthetic conduits (39% vs. 30%, P = 0.001), and less frequently had tibial/pedal targets (32% vs. 40%, P = 0.002). After adjusting for these and other confounders, multivariable analysis demonstrated that the use of CTA/MRA alone was not associated with a significant

  20. Triple Arterial Phase MR Imaging with Gadoxetic Acid Using a Combination of Contrast Enhanced Time Robust Angiography, Keyhole, and Viewsharing Techniques and Two-Dimensional Parallel Imaging in Comparison with Conventional Single Arterial Phase

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jeong Hee [Department of Radiology, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Department of Radiology, Seoul National University College of Medicine, Seoul 03087 (Korea, Republic of); Lee, Jeong Min [Department of Radiology, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Department of Radiology, Seoul National University College of Medicine, Seoul 03087 (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 03087 (Korea, Republic of); Yu, Mi Hye [Department of Radiology, Konkuk University Medical Center, Seoul 05030 (Korea, Republic of); Kim, Eun Ju [Philips Healthcare Korea, Seoul 04342 (Korea, Republic of); Han, Joon Koo [Department of Radiology, Seoul National University Hospital, Seoul 03080 (Korea, Republic of); Department of Radiology, Seoul National University College of Medicine, Seoul 03087 (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 03087 (Korea, Republic of)

    2016-11-01

    To determine whether triple arterial phase acquisition via a combination of Contrast Enhanced Time Robust Angiography, keyhole, temporal viewsharing and parallel imaging can improve arterial phase acquisition with higher spatial resolution than single arterial phase gadoxetic-acid enhanced magnetic resonance imaging (MRI). Informed consent was waived for this retrospective study by our Institutional Review Board. In 752 consecutive patients who underwent gadoxetic acid-enhanced liver MRI, either single (n = 587) or triple (n = 165) arterial phases was obtained in a single breath-hold under MR fluoroscopy guidance. Arterial phase timing was assessed, and the degree of motion was rated on a four-point scale. The percentage of patients achieving the late arterial phase without significant motion was compared between the two methods using the χ{sup 2} test. The late arterial phase was captured at least once in 96.4% (159/165) of the triple arterial phase group and in 84.2% (494/587) of the single arterial phase group (p < 0.001). Significant motion artifacts (score ≤ 2) were observed in 13.3% (22/165), 1.2% (2/165), 4.8% (8/165) on 1st, 2nd, and 3rd scans of triple arterial phase acquisitions and 6.0% (35/587) of single phase acquisitions. Thus, the late arterial phase without significant motion artifacts was captured in 96.4% (159/165) of the triple arterial phase group and in 79.9% (469/587) of the single arterial phase group (p < 0.001). Triple arterial phase imaging may reliably provide adequate arterial phase imaging for gadoxetic acid-enhanced liver MRI.

  1. Triple arterial phase MR imaging with gadoxetic acid using a combination of contrast enhanced time robust angiography, keyhole, and viewsharing techniques and two-dimensional parallel imaging in comparison with conventional single arterial phase

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jeong Hee; Lee, Jeong Min; Han, Joon Koo [Dept. of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Yu, Mi Hye [Dept. of Radiology, Konkuk University Medical Center, Seoul (Korea, Republic of); Kim, Eun Ju [Philips Healthcare Korea, Seoul (Korea, Republic of)

    2016-07-15

    To determine whether triple arterial phase acquisition via a combination of Contrast Enhanced Time Robust Angiography, keyhole, temporal viewsharing and parallel imaging can improve arterial phase acquisition with higher spatial resolution than single arterial phase gadoxetic-acid enhanced magnetic resonance imaging (MRI). Informed consent was waived for this retrospective study by our Institutional Review Board. In 752 consecutive patients who underwent gadoxetic acid-enhanced liver MRI, either single (n = 587) or triple (n = 165) arterial phases was obtained in a single breath-hold under MR fluoroscopy guidance. Arterial phase timing was assessed, and the degree of motion was rated on a four-point scale. The percentage of patients achieving the late arterial phase without significant motion was compared between the two methods using the χ2 test. The late arterial phase was captured at least once in 96.4% (159/165) of the triple arterial phase group and in 84.2% (494/587) of the single arterial phase group (p < 0.001). Significant motion artifacts (score ≤ 2) were observed in 13.3% (22/165), 1.2% (2/165), 4.8% (8/165) on 1st, 2nd, and 3rd scans of triple arterial phase acquisitions and 6.0% (35/587) of single phase acquisitions. Thus, the late arterial phase without significant motion artifacts was captured in 96.4% (159/165) of the triple arterial phase group and in 79.9% (469/587) of the single arterial phase group (p < 0.001). Triple arterial phase imaging may reliably provide adequate arterial phase imaging for gadoxetic acid-enhanced liver MRI.

  2. Usefulness of CT angiography after metallic stent implantation of the internal carotid artery

    International Nuclear Information System (INIS)

    Yoon, Man Won; Kim, Hyeon Chul; Kim, Jae Kyu; Seo, Jeong Jin; Jeong, Gwang Woo; Kang, Heoung Keun

    1999-01-01

    To evaluate the usefulness of CT angiography in patients with implantation of metallic stent for stenosed internal carotid artery. Seven patients with atherosclerotic stenosis of the internal carotid artery underwent metallic stent implantation. All were male and their ages ranged from 36 to 69 years. A total of seven stents were placed in the internal carotid artery in five patients and in the carotid bifurcation in two. Spiral CT scans were obtained and CT angiographic images were reconstructed using MPR or curved MPR techniques at a workstation. The interval between CT and conventional angiography did not exceed six days except in one patient, in whom it was 61days. CT and conventional angiography were compared for stent position with respect to the carotid bifurcation, stent deformation, intraluminal filling defect, and luminal caliber and outflow. Luminal patency of the implanted stent was measured according to NASCET(North American Symptomatic Carotid Endarterectomy Trial) criteria, and statistically processed (p>.05). The presence or absence of intrastent thrombus and vascular wall calcification was determined using axial source images. In all patients, CT angiographic findings matched those obtained by conventional angiography. Complications such as migration or deformation of an implanted stent, intraluminal filling defect, change of luminal caliber or outflow of implanted stent were not observed in any patient. In two studies in which Wilcoxon signed rank test was used, degree of stent expansion correlated closely(p=0.237). Axial source images showed that in no patient was an intrastent thrombus present, though in five, vascular wall calcification of internal carotid arteries outside the stent was noted. CT angiography is useful for the assessment of positional change, occlusion, and luminal patency of a stent-implanted internal carotid artery

  3. Gallbladder visualization on CT shortly after angiography with ioxaglate

    International Nuclear Information System (INIS)

    Tajima, H.; Kaizu, T.; Ichikawa, T.; Kumazaki, T.

    1994-01-01

    Thirty-five patients underwent CT examination 15 to 30 min after abdominal angiography with ioxaglate. The gallbladder was visualized in 12 patients in the absence of clinical evidence of renal impairment. Gallbladder opacification on CT examinations shortly after angiography shows that the hepatobiliary tract is important in the excretion of ioxaglate. (orig.)

  4. Microembolism after cerebral angiography

    International Nuclear Information System (INIS)

    Manaka, Hiroshi; Sakai, Hideki; Nagata, Izumi

    2000-01-01

    Acute microemboli are detected more precisely with the recently developed diffusion-weighted MR imaging (DWI). We happened to obtain 24 DWIs after 350 diagnostic cerebral angiographies in 1999. DWIs after cerebral angiographies showed bright lesions in 7 patients (28%), of whom 6 had no neurological symptoms after cerebral angiography. Seven of the 24 patients had risk factors for arteriosclerosis. Only one patient had embolic events due to angiography. Microemboli related to cerebral angiographies are inevitable in some patients. Most are silent, however, we should investigate the cause of microemboli and should make cerebral angiography safer. (author)

  5. MR angiography in pediatric neurological disorders

    International Nuclear Information System (INIS)

    Lee, B.C.P.; Park, T.S.; Kaufman, B.A.

    1995-01-01

    MR angiography using 3D and 2D time-of-flight techniques were used to evaluate pediatric neurological disorders. MRA (arteriography) and MRV (venography) were abnormal in 63 and 45 cases, respectively. Conventional cerebral angiography was performed in 30 cases. These techniques were compared with MRI and conventional angiography. In addition, the value of MR angiography for surgical planning was subjectively evaluated. Our results showed that intracranial vessels were invariably better shown on MR angiography than on MRI. MRA and MRV were most useful in evaluating vascular distortions related to congenital brain malformations and intracranial tumors. MRA was valuable in detecting arterial narrowing but overestimated the degree of stenosis compared with conventional angiography. MRV was the technique of choice for evaluation of dural sinus and cerebral venous thrombosis and compression. MRA played little to no role in preoperative planning of vascular malformations and aneurysms. It did not appear to be accurate in assessing tumor vascularity or lesions in small arteries and arteritis. (orig.)

  6. Recent results and future prospects of dynamic intravenous coronary angiography using synchrotron radiation

    International Nuclear Information System (INIS)

    Ohtsuka, Sadanori

    1999-01-01

    We have developed a dynamic intravenous coronary angiography (IVCAG) by using synchrotron radiation (SR) as a less invasive and more easy examination in place of CAG. Twelve patients suspected to have angina pectoris underwent IVCAG at the clinic in the National Laboratory for High Energy Accelerator Research Organization (KEK). The patients received an intravenous injection of 40m/of contrast agent, and then irradiation was performed with a wide (130 mm x 80 mm) and monochromatic (35 KeV) X-ray beam. Images were acquired with an image intensifier and recorded with a digital fluorography system as dynamic angiography at 30 or 10 images/sec. IVCAG was repeated in 2 or 3 projections. In all patients, the dynamic images permitted clear visualization of the coronary arteries and enabled evaluation of coronary anatomy. Two patients were diagnosed to have coronary stenosis by IVCAG and were confirmed by conventional CAG. The total irradiation doses used for IVCAG were less than those for conventional angiography. Although the image definition obtained with dynamic IVCAG was somewhat less than that of conventional CAG and needs to be improved, the IVCAG can be easily used for the evaluation of coronary arteries and may be clinically used for screening and follow-up of coronary artery disease. In future, the improvement of imaging system, such as increased intensity of synchrotron radiation and high sensitivity in imaging detector, will make more advance in image quality. (author)

  7. Angiography in angiology

    International Nuclear Information System (INIS)

    Zeitler, E.; Grosse-Vorholt, R.

    1980-01-01

    A review is given of recent developments in angiography including advances in the equipment, in the technique and in image processing. Indications for and interpretation of angiography are discussed and angiographic-therapeutic procedures are considered. (C.F.)

  8. Evaluation of protocolized angiography in performing the interventional procedure for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Jiang Jianqiang; Shi Haibin; Liu Sheng; Yang Zhengqiang; Zhou Chungao; Zhou Weizhong

    2010-01-01

    Objective: To assess the clinical value of protocolized angiography,including the superior mesenteric artery (SMA), the celiac artery and the common hepatic artery angiography, in detecting the atypical tumor feeding arteries of hepatocellular carcinoma (HCC) during transarterial chemoembolization (TACE) procedure. Methods: The clinical data of all patients who received the initial TACE for HCC during the period of January 2005-December 2009 were collected and were retrospectively analyzed. Both the angiograms and procedure reports were reviewed. According to the angiography protocols used in interventional procedure the patients were divided into two groups. Group A included 526 patients who received the protocolized angiography, including the SMA, the celiac artery and the common hepatic artery, while Group B composed of 850 patients who underwent the routine angiography of the common hepatic artery. For all patients in both groups the atypical tumor feeding arteries were searched for when the tumor staining was incomplete. The anatomic variations of tumor feeding arteries were classified and were statistically analyzed. Results: The detection rate of tumor supply from the branches of SMA, left gastric artery, phrenic artery and celiac artery was 14.1%, 6.7%, 4.6% and 0.5% respectively in group A, while it was 8.9%, 3.3%, 2.6% and 0% respectively in group B. Significant difference in all above four detection rates existed between two groups (P 0.05). Conclusion: Compared with the conventional common hepatic arteriography during TACE, the diagnostic protocolized angiography, including the SMA, the celiac artery and the common hepatic artery, can markedly improve the detection rates of atypical tumor feeders of HCC, such as the accessory hepatic artery, which means that the tumor will be occluded more completely and be controlled more promptly. (authors)

  9. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    Energy Technology Data Exchange (ETDEWEB)

    Pugliese, Francesca; Krestin, Gabriel P. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Mollet, Nico R.A.; deFeyter, Pim J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Runza, Giuseppe [University of Palermo, Department of Radiology, Palermo (Italy); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy); Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Malagutti, Patrizia [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); University of Ferrara, Department of Cardiology, Ferrara (Italy); Cademartiri, Filippo [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy)

    2006-03-15

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as {>=} 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  10. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    International Nuclear Information System (INIS)

    Pugliese, Francesca; Krestin, Gabriel P.; Mollet, Nico R.A.; DeFeyter, Pim J.; Runza, Giuseppe; Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo; Malagutti, Patrizia; Cademartiri, Filippo

    2006-01-01

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as ≥ 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  11. MR angiography in the evaluation of a renovascular cause of neonatal hypertension

    International Nuclear Information System (INIS)

    Mustafa, Amira E.; Valentini, Rudolph P.; Mattoo, Tej K.; Bloom, David A.; Imam, Abubakr A.

    2006-01-01

    Neonatal hypertension occurs in 2% of all infants and it is caused by renovascular abnormalities in 70% of these infants. The gold standard for diagnosing renovascular disease is conventional renal angiography. However, in neonates the procedure is not commonly used because of its invasive and technically challenging nature. MRI and MR angiography (MRA) are less invasive yet reliable means of detecting renovascular disease in adults. There is minimal literature on the use of MRI/MRA in neonatal hypertension. We report a neonate with hypertension secondary to a renovascular abnormality in which MRI/MRA was helpful in uncovering segmental renal artery stenosis. The infant underwent partial nephrectomy with subsequent resolution of his hypertension. Further studies are needed to validate the use of MRI/MRA in the evaluation of neonatal hypertension. (orig.)

  12. Clinical application of gadolinium-enhanced three-dimensional pulmonary MR angiography

    International Nuclear Information System (INIS)

    Takano, Katsuyuki

    1999-01-01

    Twenty-nine patients with suspected pulmonary lesions, and three normal volunteers, underwent gadolinium-enhanced three-dimensional (3D) pulmonary MR angiography (MRA). The MRA were obtained during intravenous administration of gadolinium-based contrast material, in a single breath-hold. Conspicuity of the normal pulmonary segmental arteries was estimated on the MRA. Abnormal findings such as ''vascular involvement'', ''abnormal connection'', stenosis'', or ''dilatation'' on the MRA were compared with those on conventional angiography or CT. Normal pulmonary segmental arteries, except for A 4,5,6,8and9 of the left pulmonary artery, could be clearly visualized. Blind reading of four different findings lead to characteristic findings for each pulmonary disease that can be aid in their differential diagnoses. This technique shows promise as a noninvasive diagnosis of lung diseases. (author)

  13. Ultra-wide-field angiography improves the detection and classification of diabetic retinopathy.

    Science.gov (United States)

    Wessel, Matthew M; Aaker, Grant D; Parlitsis, George; Cho, Minhee; D'Amico, Donald J; Kiss, Szilárd

    2012-04-01

    To evaluate patients with diabetic retinopathy using ultra-wide-field fluorescein angiography and to compare the visualized retinal pathology with that seen on an overly of conventional 7 standard field (7SF) imaging. Two hundred and eighteen eyes of 118 diabetic patients who underwent diagnostic fluorescein angiography using the Optos Optomap Panoramic 200A imaging system were included. The visualized area of the retina, retinal nonperfusion, retinal neovascularization, and panretinal photocoagulation were quantified by two independent masked graders. The respective areas identified on the ultra-wide-field fluorescein angiography image were compared with an overly of a modified 7SF image as outlined in the Early Treatment Diabetic Retinopathy Study. Ultra-wide-field fluorescein angiograms imaging, on average, demonstrated 3.2 times more total retinal surface area than 7SF. When compared with 7SF, ultra-wide-field fluorescein angiography showed 3.9 times more nonperfusion (P diabetic retinopathy. Improved retinal visualization may alter the classification of diabetic retinopathy and may therefore influence follow-up and treatment of these patients.

  14. Experience with intravenous digital subtraction angiography following shunting in 4 cases of congenital heart diseases

    Energy Technology Data Exchange (ETDEWEB)

    Higashidate, Masafumi; Konno, Susumu; Sumitomo, Naokata; Ito, Sango; Kobayashi, Hiroshi

    1985-01-01

    Intravenous digital subtraction angiography (IV-DSA) was performed in two patients with Fallot's tetralogy who underwent Blalock-Taussing operation, a patient with coarctation of the aortic arch who underwent extra-anastomic bypass between the ascending aorta and the descending aorta, and a patient with stenosis of the tricuspid valve who underwent Fontan type operation (anastomosis between the right atrium and the pulmonary artery). The conventional cardiac angiography was also performed for the comparison with IV-DSA in all patients. IV-DSA revealed the thickness of the subclavian artery anastomosed by Blaloch-Taussing operation, but failed to determine the accurate thickness of the pulmonary artery required for PA-index for radical surgery in cases of Fallot's tetralogy. Bypass from the ascending aorta to the descending aorta was well visualized by IV-DSA because the heart did not overlap on the image. In cases of Fontan type operation, IV-DSA permitted the visualization of blood flow from the right atrium to the pulmonary artery and the shape of the pulmonary artery. It is concluded that IV-DSA is a less invasive, simple technique to evaluate patients' condition following shunting for congenital heart diseases, as compared to the conventional method. (Namekawa, K.).

  15. Experience with intravenous digital subtraction angiography following shunting in 4 cases of congenital heart diseases

    International Nuclear Information System (INIS)

    Higashidate, Masafumi; Konno, Susumu; Sumitomo, Naokata; Ito, Sango; Kobayashi, Hiroshi

    1985-01-01

    Intravenous digital subtraction angiography (IV-DSA) was performed in two patients with Fallot's tetralogy who underwent Blalock-Taussing operation, a patient with coarctation of the aortic arch who underwent extra-anastomic bypass between the ascending aorta and the descending aorta, and a patient with stenosis of the tricuspid valve who underwent Fontan type operation (anastomosis between the right atrium and the pulmonary artery). The conventional cardiac angiography was also performed for the comparison with IV-DSA in all patients. IV-DSA revealed the thickness of the subclavian artery anastomosed by Blaloch-Taussing operation, but failed to determine the accurate thickness of the pulmonary artery required for PA-index for radical surgery in cases of Fallot's tetralogy. Bypass from the ascending aorta to the descending aorta was well visualized by IV-DSA because the heart did not overlap on the image. In cases of Fontan type operation, IV-DSA permitted the visualization of blood flow from the right atrium to the pulmonary artery and the shape of the pulmonary artery. It is concluded that IV-DSA is a less invasive, simple technique to evaluate patients' condition following shunting for congenital heart diseases, as compared to the conventional method. (Namekawa, K.)

  16. Evaluation of peripheral artery stent with 64-slice multi-detector row CT angiography: Prospective comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Li Xiaoming; Li Yuhua; Tian Jianming; Xiao Yi; Lu Jianping; Jing Zaiping; Sheng Jing; Edwin, Angela; Wu Fanghong

    2010-01-01

    Purpose: To assess the accuracy of 64-slice multi-detector row computed tomography (MDCT) angiography in the evaluation of peripheral artery in-stent or peristent restenosis, with conventional digital subtraction angiography (DSA) as the reference standard. Materials and methods: Forty-one patients (30 men, 11 women; mean age, 69.8 ± 9.2 years) with symptomatic peripheral arterial occlusive disease after peripheral artery stenting (81 stented lesions) underwent both conventional DSA and 64-slice MDCT angiography. Each stent was classified as evaluable or unevaluable, and every stent was divided into three segments (proximal stent, stent body, and distal stent), resulting in 243 segments. For evaluation, stenosis was graded as follows: 1, none or slight stenosis (<25%); 2, mild stenosis (25-49%); 3, moderate stenosis (50-74%); 4, severe stenosis or total occlusion (≥75%). Two readers evaluated all CT angiograms with regard to narrowing of in-stent or peristent restenosis by consensus. Results were compared with findings of the DSA. Results: Of 81 stents, 62 (76.5%) were determined to be assessable. The metal artifact of the gold marker and motion artifact increased uninterpretability of the images of stents. Overall, 24 of 28 in-stent restenosis and 38 of 53 persistent restenosis were correctly detected by MDCT (85.7% and 71.7% sensitivity). In evaluable stents, 21 of 22 in-stent restenoses and 27 of 28 persistent restenosis were correctly detected (95.4% and 96.4% sensitivity). Additionally, as the grade of stenosis increases, the mean level of CT values in the stent lumina decreases linearly accordingly. Conclusion: 64-Slice MDCT has a high accuracy for the detection of significant in-stent or peristent restenosis of assessable stents in patients with peripheral artery stent implantation and therefore can be considered as a valuable noninvasive technique for stent surveillance.

  17. Clinical application of digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Morimoto, Tadashi; Kaku, Suiei; Morikawa, Eiji

    1984-01-01

    Intra-arterial digital subtraction angiography (IA-DSA) by the direct puncture of the carotid artery was described with special reference to its techniques, and cases were presented. This method was safe and painless and could be performed repeatedly. Cerebral angiographic images obtained by this method were either superior or fully compatible to the conventional cerebral angiography. It is therefore of great diagnostic value and can replace the conventional method. Furthermore, since the pretreatment is unnecessary and the time required is short, IA-DSA can be used as an adjuvant method for emergency diagnosis. (Namekawa, K)

  18. Magnetic resonance angiography of arteriovenous malformation in the thalamus

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Hirofumi; Kida, Yoshihisa; Kobayashi, Tatsuya; Tanaka, Takayuki; Iwakoshi, Takayasu; Kai, Osamu; Hirose, Mitsuhiko [Komaki City Hospital, Aichi (Japan)

    1993-11-01

    A comparative study of magnetic resonance angiography and conventional angiography of arteriovenous malformation in the thalamus showed that both methods clearly visualized the feeding arteries: perforating branches of the posterior cerebral artery, posterior choroidal artery and lenticulostriate artery. Draining veins such as the internal cerebral vein were also demonstrated well. (author).

  19. Magnetic resonance angiography (MRA)

    International Nuclear Information System (INIS)

    Arlart, I.P.; Guhl, L.

    1992-01-01

    An account is given in this paper of the physical and technical principles underlying the 'time-of-flight' technique for imaging of vessels by magnetic resonance tomography. Major indications for the new procedure of magnetic resonance angiography at present are intracerebral and extracerebral vessels, with digital subtraction angiography quite often being required to cope with minor alterations (small aneurysms, small occlusions). Magnetic resonance angiography and digital subtraction angiography are compared to each other for advantages and disadvantages. Basically, replacement of radiological angiography by magnetic resonance angiography appears to be possible only within limits, since X-ray diagnostics primarily provides morphological information about vessels, whereas flow dynamics is visualized by the 'time-of-flight' technique. (orig.) [de

  20. MR-angiography

    International Nuclear Information System (INIS)

    Seiderer, M.

    1989-01-01

    Three categories of MRI techniques for vascular imaging are discussed: 2d-angiography using rephasing and dephasing pulse sequences and slice selective imaging; 3d-angiography using rehpasing and dephasing pulse sequences and fas 3d-imaging techniques; 3d-angiography using signal intensity modulation caused by pre- and post-contrast data acquisition (e.g. Gadolinium-DTPA) in combination with fast 3d-imaging (only one type of pulse sequence). (H.W.). 6 figs

  1. Abdominal MR angiography

    International Nuclear Information System (INIS)

    Wegmueller, H.; Vock, P.

    1993-01-01

    The two techniques currently most often used for MR angiography, those based on time-of-flight effects and on phase-contrast, are introduced, and our results with three-dimensional phase contrast angiography of the abdomen are presented. Several basic differences from other imaging procedures render MR angiography clinically useful for screening for renal artery stenosis in critical situations, such as renal failure or intolerance to contrast agents. In the future, the spectrum of applications of MR angiography will broaden and include other indications, such as portal venous hypertension and follow-up studies after surgical portal systemic shunting. (orig.) [de

  2. Evaluation of diagnostic accuracy of cerebral aneurysms on MR angiography

    International Nuclear Information System (INIS)

    Miki, Hitoshi

    1996-01-01

    The purpose of this study was to evaluate the diagnostic accuracy of MR angiography (MRA) for detection of intracranial aneurysms (IAs) by prospective and retrospective examinations. The detection rates for MRA were: 3D time-of-flight (TOF), 94.2% (n=69); 3D phase contrast (PC), 75% (n=20); 2D TOF, 68% (n=25); and 2D PC, 59.4% (n=32). In aneurysms smaller than 5-mm, the detection rates were: 3D TOF, 87.9% (n=33); 3D PC, 42.9% (n=7); 2D TOF, 0% (n=8); and 2D PC, 14.3% (n=14). In the detection of IAs smaller than 5-mm, 3D TOF was superior to other MRA methods. Four IAs could not be detected by 3D TOF with a standard voxel size. These four IAs smaller than 3-mm were detected by 3D TOF with a small voxel size. In the blinded examination, the detection rate of IAs using MIP images was 71.8%, however, it using MIP and source images was 93.5%. False positive cases were reduced by using source images. In prospective study including 200 cases, IAs smaller than 5-mm were detected in 12 individuals underwent conventional angiography or CT angiography. Seven of them were true positive, however, 5 smaller than 2-mm on MRA were false positive. In conclusions, IAs 3-mm or larger can be identified by 3D TOF MRA with a small voxel size; however, IAs smaller than 2-mm on MRA are difficult to detect without false positive. (author)

  3. Effective selection of hypertensive patients for angiography

    International Nuclear Information System (INIS)

    van der Voorde, F.; Derkx, F.H.M.; Bossuyt, P.M.M.; Segaar, R.W.; de Wind, A.; Pieterman, H.

    1989-01-01

    The authors prospectively observed 373 severe hypertensives with either diastolic blood pressure (BP) ≥ 105 and age ≤ 40, or BP with three drugs ≥ 105 (regardless of age). Excluded were patients who were older than 75 or who had creatinine >400. History, physical examination, and laboratory data were used to identify high-yield criteria for arteriography. All patients underwent angiography as the gold standard; angiography showed 127 unilateral renal artery stenoses, 73 bilateral renal artery stenoses, and 173 (nonstenosed) essential hypertensives. The authors constructed a logistic regression model of height, weight, age, smoking, and hypertension duration, which could be used to identify 90% of stenosed patients with 50% fewer angiographies in the essential hypertensives

  4. Magnetic resonance angiography: infrequent anatomic variants

    International Nuclear Information System (INIS)

    Trejo, Mariano; Meli, Francisco; Lambre, Hector; Blessing, Ricardo; Gigy Traynor, Ignacio; Miguez, Victor

    2002-01-01

    We studied through RM angiography (3D TOF) with high magnetic field equipment (1.5 T) different infrequent intracerebral vascular anatomic variants. For their detection we emphasise the value of post-processed images obtained after conventional angiographic sequences. These post-processed images should be included in routine protocols for evaluation of the intracerebral vascular structures. (author)

  5. The value of 3D-CT angiography and duplex sonography in comparison to arteriography in carotid artery stenoses

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Wesner, F.; Hoepfner, M.; Schwarzenberg, H.; Heller, M.

    1997-01-01

    To determine the value of 3D-CT angiography, duplex sonography in comparison to selective digital subtraction angiography for evaluation of carotid artery stenoses. Methods: 30 patients with 51 stenoses of carotid artery underwent 3D-CT angiography, duplex sonography and angiography. Quantification of stenosis was determined according to the NASCET study and categorized into mild (0-29%), moderate (30-69%), severe (70-99%) and occluded (100%). Results: The agreement of 3D-CT angiography with intraarterial digital subtraction angiography (DSA) was 62% (r=0.89; p [de

  6. Cardiac CT angiography after coronary artery surgery in children using 64-slice CT scan

    International Nuclear Information System (INIS)

    Marini, Davide; Agnoletti, Gabriella; Brunelle, Francis; Sidi, Daniel; Bonnet, Damien; Ou, Phalla

    2009-01-01

    Objective: The purpose of this study was to compare the diagnostic accuracy of 64-slice CT with that of invasive angiography in the detection of graft and/or coronary angioplasty stenosis in children who had undergone coronary artery surgery. Population and methods: Fifteen consecutive children (8 male and 7 female; age 9.2 ± 6.1 years) underwent 64-slice CT because of chest pain or ECG changes mean 4.8 ± 3.7 years after surgical coronary artery surgery; 10 patients had coronary angioplasty using a patch from the saphenous vein, four had mammary artery bypass, and one had saphenous vein bypass. Six main segments of the coronary arteries and all the bypass graft considered as a single segment were analyzed and compared with invasive angiography used as the reference standard. Results: CT correctly identified the four children with coronary angioplasty and mammary graft lesions that were confirmed by conventional angiography: one patient had a significant stenosis (>50% stenosis) at the mammary bypass graft anastomosis site; three other had non-significant stenosis (<50% stenosis) including a mild lesion of the saphenous vein patch in two patients and a mild lesion at the anastomosis site of the mammary bypass in one. All segments identified as normal by CT in the other 11 children were also found to be normal by conventional angiography. Conclusion: In centers expert in this technique, 64-slice CT scanning is a promising, rapid, and useful diagnostic technique for evaluating both coronary angioplasty and bypass graft lesions in children who had undergone coronary artery surgery.

  7. Digital subtraction angiography of the thoracic aorta

    International Nuclear Information System (INIS)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-01-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram

  8. Digital subtraction angiography of the thoracic aorta

    Energy Technology Data Exchange (ETDEWEB)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-02-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram.

  9. Gallbladder visualization on CT shortly after abdominal angiography with iodixanol

    International Nuclear Information System (INIS)

    Tajima, Hiroyuki; Murakami, Ryusuke; Goto, Shinsuke; Aoyama, Toshiya; Kaizu, Toshihide; Ichikawa, Taro; Kumazaki, Tatsuo; Onda, Masahiko

    1996-01-01

    Fifteen patients underwent CT examination shortly after abdominal angiography with iodixanol. Gallbladder opacification was observed in 13 patients in the absence of clinical evidence of renal impairment. Among them, 2 patients showed a strong opacification on CT. There was no significant relationship between visualization of the gallbladder and the total dose of contrast medium. Gallbladder opacification on CT examination shortly after angiography shows that the hepatobiliary tract is important in the excretion of iodixanol. (author)

  10. The pattern of renal vessels in live related potential donors pool. A multislice computed tomography angiography review

    International Nuclear Information System (INIS)

    Mishra, A.; Ehtuish, Ehtuish F.

    2006-01-01

    To assess the renal vessel anatomy, compare the findings with the perioperative findings, to determine the sensitivity of multislice computed tomography (CT) angiography in the work-up of live potential donors and to discuss and compare the results of the present study with the reported results using single slice CT, magnetic resonance (MRI) and conventional angiography (CA).Retrospective analysis of the angiographic data of 118 of prospective live related kidney donors was carried out from October 2004 to August 2005 at the National Organ Transplant Centre, Tripoli Central Hospital, Libya. All donors underwent renal angiography on multislice (16-slice) CT scan using 80 cc intravenous contrast with 1.25 mm slice thickness followed by maximum intensity projection (MIP) and volume rendering techniques (VRT) post-processing algorithms. The number of vessels, vessel bifurcation, vessel morphology and venous anatomy were analyzed and the findings were compared with the surgical findings. Multislice spiral CT angiography (MSCTA) showed clear delineation of the main renal arteries in all donors with detailed vessel morphology. The study revealed 100% sensitivity in detection of accessory renal vessels, with an overall incidence of 26.7%, which is the most common distribution in the parahilar region. The present study showed 100% sensitivity in the visualization and detection of main and accessory renal vessels. These results were comparable with conventional angiography which has so far been considered as the gold standard and were found superior in specificity and accuracy to the use of single slice CT (SSCT) and MR in the angiographic work-up of live renal donors. Due to improved detection of accessory vessels less than 2 mm in diameter, a higher incidence of aberrant vessels was seen on the right side as has been suggested so far. (author)

  11. CT angiography of the renal arteries and veins: normal anatomy and variants.

    Science.gov (United States)

    Hazırolan, Tuncay; Öz, Meryem; Türkbey, Barış; Karaosmanoğlu, Ali Devrim; Oğuz, Berna Sayan; Canyiğit, Murat

    2011-03-01

    Conventional angiography has long been regarded as gold standard imaging modality for evaluation of the renal vasculature. Introduction of multidetector computed tomography (MDCT) angiography had a groundbreaking impact on evaluation of the renal vessels and is gradually replacing conventional angiography as standard imaging. Herein, we review and illustrate the normal and variant anatomy of renal vessels with special emphasis on imaging protocols and reconstruction techniques in MDCT.

  12. Three dimensional CT angiography (3D-CTA) in ruptured aneurysm surgery on acute stage

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Endo, Yuji; Nakano, Masayuki

    1998-01-01

    We evaluated three-dimensional CT angiography (3D-CTA) for the treatment of acutely ruptured cerebral aneurysms. Sixty patients with subarachnoid hemorrhage from cerebral aneurysms were investigated both by 3D-CTA and conventional angiography and 26 patients were studied using 3D-CTA without conventional angiography. In the 60 cases, both 3D-CTA and the conventional angiography revealed 100% accuracy in diagnosing ruptured aneurysms, and 3D-CTA and the conventional angiography showed 96% and 92% accuracy for unruptured aneurysms respectively. 3D-CTA was equal or superior to the conventional angiography. Based on these data, since December, 1996, we have operated on 26 consecutive patients with ruptured aneurysms located in the anterior circulation of the circle of Willis, using 3D-CTA without conventional angiography. Thirty-one aneurysms, including 5 associated unruptured aneurysms, were visualized by 3D-CTA and verified at surgery. All aneurysms were clipped successfully. We think that it will be possible to operate on most ruptured aneurysms using only 3D-CTA without the conventional angiography except for the cases of the following situations: if a cerebral infarction is present, conventional angiography is required to evaluate for a stenotic or occlusive lesion of the intracranial arteries, cervical carotid, or vertebral arteries; in cases of giant or large aneurysms, the dynamic information provided by the conventional angiography is needed in case bypass surgery is necessary; and for aneurysms close to bony structures, such as an internal carotid-ophthalmic artery aneurysm, conventional angiography is necessary. (author)

  13. Venous digital subtraction angiography for diagnosis of renal artery stenosis in arterial hypertony

    International Nuclear Information System (INIS)

    Schoerner, W.; Kempter, H.; Banzer, D.; Aviles, C.; Weiss, T.; Felix, R.

    1984-01-01

    Venous digital subtraction angiography was performed in 248 patients for the diagnosis of renal arterial stenosis. In 88% of the investigations the stenosis could be found. Comparison of digital angiography and conventional angiography was made for 57 renal arteries (25 investigations). In 52 renal arteries we found the same results with both methods, in 5 renal arteries we found the same results with both methods, in 5 renal arteries the digital angiography showed false positive results. The spatial resolution of digital subtraction angiography is sufficient for the correct diagnosis of significant renal arterial stenosis. With regard to the lower invasion of digital subtraction angiography compared to conventional angiography the first method should be used for clarification of renal arterial hypertension. (orig.)

  14. Spiral CT angiography of renal arteries: comparison with angiography

    International Nuclear Information System (INIS)

    Wittenberg, G.; Kenn, W.; Tschammler, A.; Sandstede, J.; Hahn, D.

    1999-01-01

    A prospective study was carried out to determine the accuracy of spiral CT angiography (CTA) in the detection of renal artery stenosis (RAS). Eighty-two patients with arterial hypertension underwent CTA and digital subtraction angiography (DSA) to exclude RAS. For CTA a contrast medium bolus of 100-150 ml (flow rate 3 ml/s) was injected. A 24 or 40 s CTA was started at the origin of the superior mesenteric artery after a delay time determined by test bolus injection (collimation = 2 mm, pitch = 1/1.5). For stenosis detection transverse images supported by maximum intensity projections (MIP) or multiplanar reconstruction projections were used. Of 197 renal arteries examined (including 33 accessory arteries), 34 RAS were visualized using DSA. With CTA, one hemodynamic RAS was missed and one additional hemodynamic RAS was found. Sensitivity/specificity was calculated to be 94 %/98 %. For hemodynamically relevant RAS (> 50 %) the sensitivity/specificity was 96 %/99 %. CTA additionally depicted five adrenal masses. The high accuracy rate of RAS detection thus allows the use of CTA as a screening method in patients with arterial hypertension to exclude a renovascular cause. (orig.)

  15. Evaluation of three-dimensional angiography for surgery of aneurysms on the anterior communicating artery

    International Nuclear Information System (INIS)

    Isobe, Naoyuki; Oki, Shuichi; Murakami, Taro; Ooyama, Shigeru; Kureshima, Makoto; Kurokawa, Yasuharu

    2007-01-01

    Obtaining detailed anatomical information is crucial before aneurysm microsurgery. The anterior cerebral communicating artery complex (AcoC) is particularly complicated compared to other parts. The anatomical structure of the AcoC is sometimes difficult to understand using conventional angiography. We evaluated the advantages of 3-dimensional digital angiography (3D-DA) for aneurysm microsurgery on the anterior cerebral communicating artery. Subjects comprised 10 men and 5 women (mean age, 61 years; range, 33-79 years) who underwent surgery in our hospital between November 2002 and October 2005. Twelve aneurysms were ruptured, and 3 aneurysms were unruptured. We compared 3D-DA images and surgical findings to assess aneurysmal morphology and relationships to neighboring vessels. We also examined both the presence and visualization of variations on AcoC. In all cases, surgical findings corresponded well to 3D-DA images. Variations on AcoC included fenestration (n=3), azygos (n=1) and aplasia or hypoplasia of the A1 segment of a unilateral anterior cerebral artery (n=9), and these were all well-visualized in 3D-DA. In addition, 3D-DA was also useful for aneurysms with 2 domes for selection of surgical approach, and provided assessment of not only aneurysmal morphology, but also variations of AcoC. This tool provided useful information for the selection of operation approach and intraoperative manipulations by using it together with 2-dimensional digital substraction angiography. (author)

  16. Coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2009-07-01

    Coronary CT angiography has attained increasing scientific attention at academic institutions and has become a highly accurate diagnostic modality. Extending this knowledge into a practice setting is the purpose of 'Coronary CT Angiography'. This book will assist you in integrating cardiac CT into your daily practice, while also giving an overview of the current technical status and applications. The specific features of scanners from all four main vendors are also presented providing an objective overview of noninvasive coronary angiography using CT. (orig.)

  17. Indications for coronary angiography

    International Nuclear Information System (INIS)

    Kaltenbach, M.; Vallbracht, C.

    1985-01-01

    Today selective coronary angiography, introduced by Sones in 1957, is used as clinical routine for diagnosing morphological changes in the coronary arteries. Hitherto, more recent techniques such as digital subtraction angiography cannot provide comparable information. Strict criteria for its indication depending on possible therapeutic consequences, have to be applied, although the risk is low with a letality of 0.01 to 0.05 percent. Radionuclear investigations can be used as additional tool in selected cases. The careful indication for coronary angiography usually implies the possible need for coronary bypass graft surgery of balloon angioplasty. (orig./MG) [de

  18. Comparison between angiography and CT scan in the urologic field

    Energy Technology Data Exchange (ETDEWEB)

    Fujioka, Toshio; Takao, Masaya; Odajima, Kunio; Nakamura, Hiroshi

    1988-02-01

    Seventy-five consecutive patients with urological diseases were examined preoperatively by means of computerized tomography and renal angiography. Classification of the diseases were 53 renal diseases which included renal cell carcinoma, sarcoma, cyst, renal bleeding, arteriovenous fistula, trauma, hydronephrosis and tuberculosis, 11 vesical diseases which included bladder tumor and endometriosis, 9 adrenal diseases which included primary aldosteronism, Cushing syndrome, pheochromocytoma, and metastatic tumor, and 1 case of intra-abdominal testes. For renal diseases, both angiography and CT were useful imaging tools. For vesical diseases, CT was a more useful imaging method but, for adrenal diseases, angiography was superior to CT. CT offers certain advantages over conventional techniques but, in the near future, it may be replaced by MRI. On the contrary, angiography will remain popular for a long time, because angiography is the only way to show which vessels feed organs.

  19. Angiography - interventional diagnostic applications

    International Nuclear Information System (INIS)

    Schild, H.

    1994-01-01

    The angiography system is very different from the other systems used in diagnostic radiology. The invasivity of angiography requires special, high standards in theoretical and practical training and experience both of beginners and experienced personnel. This textbook fully meets the demand for in-depth and exhaustive information, as it presents: - The fundamentals and techniques of angiography, the vascular anatomy, and many hints and tips of great help in practice. - A comprehensive survey of diagnostic problems and examination approaches, including neuro-angiography, with 221 reproductions of original angiographs, and additional schematic representations. - A special chapter devoted to indication and relevant techniques for the major vascular interventional examinations. - A great number of tables explain at a glance standard examination techniques, indications and diagnostic criteria. (orig./CB) [de

  20. Angiography in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Zeitler, E

    1982-04-05

    We report on the cooperative possibilities the radiologist has as to diagnosis and therapy of portal hypertension. The catheter angiography allows to make a differentiation between pre- and intrahepatic bloc and the localization of bleeding esophagus varices. Only after all endoscopic measures with sclerotherapy and Laser coagulation have failed, catheter angiography will be carried out as a therapeutic measure. The future development, however, will give the opportunity to a series of therapeutic attempts on the field of interventional radiology.

  1. Angiography in portal hypertension

    International Nuclear Information System (INIS)

    Zeitler, E.

    1982-01-01

    We report on the cooperative possibilities the radiologist has as to diagnosis and therapy of portal hypertension. The catheter angiography allows to make a differentiation between pre- and intrahepatic bloc and the localization of bleeding esophagus varices. Only after all endoscopic measures with sclerotherapy and Laser coagulation have failed, catheter angiography will be carried out as a therapeutic measure. The future development, however, will give the opportunity to a series of therapeutic attempts on the field of interventional radiology. (orig.) [de

  2. Prospective Heart Tracking for Whole-heart Magnetic Resonance Angiography

    Science.gov (United States)

    Moghari, Mehdi H.; Geva, Tal; Powell, Andrew J.

    2015-01-01

    Purpose To develop a prospective respiratory-gating technique (Heart-NAV) for use with contrast-enhanced 3D inversion recovery (IR) whole-heart magnetic resonance angiography (MRA) acquisitions that directly tracks heart motion without creating image inflow artifact. Methods With Heart-NAV, 1 of the startup pulses for the whole-heart steady-state free precession MRA sequence is used to collect the centerline of k-space, and its 1-dimensional reconstruction is fed into the standard diaphragm-navigator (NAV) signal analysis process to prospectively gate and track respiratory-induced heart displacement. Ten healthy volunteers underwent non-contrast whole-heart MRA acquisitions using the conventional diaphragm-NAV and Heart-NAV with 5 and 10 mm acceptance windows in a 1.5T scanner. Five patients underwent contrast-enhanced IR whole-heart MRA using a diaphragm-NAV and Heart-NAV with a 5 mm acceptance window. Results For non-contrast whole-heart MRA with both the 5 and 10 mm acceptance windows, Heart-NAV yielded coronary artery vessel sharpness and subjective visual scores that were not significantly different than those using a conventional diaphragm-NAV. Scan time for Heart-NAV was 10% shorter (p<0.05). In patients undergoing contrast-enhanced IR whole-heart MRA, inflow artifact was seen with the diaphragm-NAV but not with Heart-NAV. Conclusion Compared to a conventional diaphragm-NAV, Heart-NAV achieves similar image quality in a slightly shorter scan time and eliminates inflow artifact. PMID:26843458

  3. Digital subtraction angiography in pediatric cerebrovascular occlusive disease

    International Nuclear Information System (INIS)

    Faerber, E.N.; Griska, L.A.B.; Swartz, J.D.; Capitanio, M.A.; Popky, G.L.

    1984-01-01

    While conventional angiography has been used to demonstrate cerebrovascular occlusive disease in the past, digital subtraction angiography (DSA) is capable of showing progressive vascular involvement with ease, simplicity, and extremely low morbidity, making it particularly well suited for children and outpatients either alone or coordinated with computed tomography. The authors discuss the usefulness and advantages of DSA as demonstrated in 7 infants and children with hemiplegia, 4 of whom had sickle-cell disease

  4. Exercise intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Yiannikas, J.

    1986-01-01

    Attempts to use exercise ventriculography have been made, not only to give diagnostic and perhaps even prognostic information in patients with coronary artery disease, but also in patients with valvular heart disease both before and after surgical intervention. Clearly an accurate method of assessing ventricular function under conditions of stress in various cardiac diseases would provide important information that would help in patient management. Exercise ventriculography using gated blood pool equilibrium technetium studies are widely used, but are limited by spatial resolution and by the foreshortening affects of visualizing the left ventricular chamber in the left anterior oblique view. First pass radionuclide studies have the added advantage of being able to visualize the ventricular chamber in the anterior or even the right anterior oblique view, but are even more limited by their spatial resolution problems. Several investigations have shown that digital subtraction angiography produces left ventricular images with a spatial resolution almost identical to that of conventional contrast ventriculography, but without the inherent problems of cardiac arrhythmias, which often limit the assessment of left ventricular function. Because of its ability to accurately delineate wall motion abnormalities, the technique may provide an adequate assessment of global and regional left ventricular function after exercise. Digital subtraction angiography may identify ischemic wall motion abnormalities produced by exercise in patients who already had significant permanent left ventricular damage from myocardial infarction

  5. Digital subtraction angiography (DSA) of the heart and coronary arteries

    International Nuclear Information System (INIS)

    Struyven, J.J.; Delcour, C.; Brion, J.P.; Vandenbosch, G.; Claessens, J.

    1986-01-01

    Digital subtraction angiography has potential advantages over conventional radiography. The removal of background structures makes possible to visualize chambers of the heart, great vessels and coronary arteries with a lower iodine signal than with conventional cineangiography. Digital data used for imaging can been manipulated for assessment and quantitation of the ventricular fonction and the coronary circulation

  6. Intra-arterial digital subtraction angiography (IA-DSA) with carbon dioxide

    International Nuclear Information System (INIS)

    Takeda, Toshiaki; Ido, Kunio; Yuasa, Yuji

    1988-01-01

    Intra-Arterial Digital Subtraction Angiography (IA-DSA) with Carbon Dioxide (CO 2 ) was performed on 41 patients mainly with liver or renal diseases, and its angiographic manifestation was compared with that of conventional angiography. Although the image quality of the arterial or capillary phase was inferior to that of conventional angiography with iodinated contrast media, the detectablity of arterio-venous shunting was excellent. In fact, DSA with CO 2 revealed the presence of A-V (A-P) shunt in 26 patients (26/41:63.4 % HCC, 13/15:86.7% metastatic liver tumor, 2/3:66.7 % RCC, 1/5:20 %). On the other hand, conventional angiography was able to show in only 5 cases. DSA with CO 2 will become an effective method for detecting minute arterio-venous shunting which can not be demonstrated with conventional angiography. (author)

  7. Intracranial MR angiography

    International Nuclear Information System (INIS)

    Davis, W.L.; Blatter, D.D.; Parker, D.L.; Robison, R.O.; Harnsberger, H.R.

    1991-01-01

    This paper compares the more traditional three-dimensional (3D) time-of-flight MR angiography with a novel new technique, MOTSA, in the evaluation of both normal and abnormal intracranial anatomy. The authors performed sequential, location-matched 3D TOF and MOTSA MR angiography in 10 subjects with normal and 25 with abnormal intracranial anatomy. Images were evaluated for visualization of specific vessels and depiction of pathologic anatomy. All images were subjected to an objective scoring system. Digital angiography was available in 15 of 25 abnormal cases. In the normal cases, large- and small-vessel visualization was improved. Significant improvement in visualization of venous anatomy was also observed. In the abnormal cases, pathologic anatomy was better visualized, providing important diagnostic information. Multiple overlapping thin-slab-acquisition MR angiography demonstrates vessel visualization that is increased over that of 3D TOF MR angiography in both normal and abnormal cases. Because of the decrease in saturation effects and phase dispersion, MOTSA is especially useful in the evaluation of complex intracranial vascular abnormalities

  8. Intraoperative digital angiography: Peripheral vascular applications

    International Nuclear Information System (INIS)

    Bell, K.; Reifsteck, J.E.; Binet, E.F.; Fleisher, H.J.

    1986-01-01

    Intraoperative digital angiography is the procedure of choice for the peripheral vascular surgeon who wishes to evaluate his results before terminating anesthesia. Two operating suites at the John L. McClellan Memorial Veterans Hospital are equipped with permanent ceiling-mounted Philips C-arm fluoroscopes and share an ADAC 4100 digital angiographic system. In the last 18 months, 40 peripheral vascular intraoperative digital angiographic procedures have been performed, in all but two cases using direct arterial puncture. In 65% of cases, the intraoperative study showed no significant abnormality. In 12.5%, minor abnormalities not requiring reoperation were seen. In 22.5% of cases, the intraoperative digital angiogram revealed a significant abnormality requiring immediate operative revision. None of the patients who underwent reoperation experienced postoperative sequelae. Intraoperative digital angiography is useful in identifying complications of peripheral vascular operations

  9. Angiography of histopathologic variants of synovial sarcoma

    International Nuclear Information System (INIS)

    Lois, J.F.; Fischer, H.J.; Mirra, J.M.; Gomes, A.S.; California Univ., Los Angeles

    1986-01-01

    Synovial sarcomas are rare soft tissue tumors which histopathologically can be divided into monophasic, biphasic and mixed variants. As part of a protocol for intra-arterial chemotherapy 12 patients with biopsy proven synovial sarcoma underwent angiography. The angiograms on these patients were reviewed to determine whether synovial sarcomas and their variants demonstrated a characteristic angiographic appearance. Synovial sarcomas appeared angiographically as soft tissue masses which showed a fine network of tumor vessels with an inhomogeneous capillary blush. Their degree of vascularity varied according to their histopathology. Monophasic synovial sarcomas demonstrated in general a higher degree of neovascularity than the biphasic form. This finding was also suggested by histopathologic analysis of the vessels in the tumor. Although angiography did not show a distinctive vascular pattern it may be useful to evaluate tumor size and vascularity. (orig.)

  10. Clinical application of magnetic resonance coronary angiography

    International Nuclear Information System (INIS)

    Murakami, Akihiko; Onoe, Teruyuki; Kodera, Akifumi; Ohtsuki, Tetsuya; Shiomi, Akio; Ida, Masaaki; Sawada, Takahisa

    1999-01-01

    We performed the magnetic resonance coronary angiography (MRCA) in the cases which underwent coronary angiography (CAG) and obtained images were compared. Lesion with significant constriction more than 75% on CAG were determined as abnormal findings on MRCA, however, lesions with about 50% constriction were as the normal findings. On the assessment of the re-constriction after PTCA, the changes in signal were found in about half of cases. This may come from the contribution of flexion lesions, the difficulty to assess moderate constriction after PTCA, etc. For the anomalous aortic origin of coronary artery, peripheral large vessels could be simultaneously imaged by MRCA and be also assessed among their clear spatial relationship. Although MRCA has some problems on the assessment for flexion or moderate constriction, these results suggested that MRCA is useful to clinical application as the non-invasive examination. (K.H.)

  11. Clinical utility and cost-effectiveness of CT-angiography in the diagnosis of nontraumatic subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Jabbarli, Ramazan; Shah, Mukesch; Hippchen, Beate; Velthoven, Vera van [University Hospital of Freiburg, Department of Neurosurgery, Freiburg/Breisgau (Germany); Taschner, Christian [University Hospital of Freiburg, Department of Neuroradiology, Freiburg (Germany); Kaier, Klaus [University Hospital of Freiburg, Institute for Medical Biometry and Medical Informatics, Freiburg (Germany)

    2014-10-15

    CT-angiography gains an increasing role in the initial diagnosis of patients with nontraumatic subarachnoid hemorrhage (SAH). However, the implementation of CT-angiography does not always exclude the necessity of conventional angiography. Our objective was to determine the practical utility and cost-effectiveness of CT-angiography. All patients with nontraumatic subarachnoid hemorrhage admitted to our university hospital after implementation of CT-angiography between June 1, 2011 and June 30, 2012 were retrospectively analyzed in regard to factors of treatment flow, radiation exposure, harms of contrast medium loading, and diagnostic costs. A control group of the same size was assembled from previously admitted SAH patients, who did not undergo pretreatment CT-angiography. Furthermore, cost-effectiveness analysis was performed. The final analysis consisted of 93 patients in each group. Of 93 patients with pretreatment CT-angiography, 74 had to undergo conventional angiography for diagnostic and/or therapeutic purposes. CT-angiography had significant impact on the reduction of collective effective radiation dose by 4.419 mSv per person (p = 0.0002) and was not associated with additional harms. Despite the significantly earlier detection of aneurysms with CT-angiography (p < 0.0001), there were no significant differences in the timing of aneurysm repair and duration of ICU and general hospital stay. There was an increase of diagnostic costs - the cost-effectiveness analysis showed, however, that benefits of CT-angiography in respect to radiation exposure and risk of conventional angiography-related complications justify the additional costs of CT-angiography. Although the implementation of CT-angiography in SAH diagnosis cannot completely replace conventional angiography, it can be approved in regard to radiation hygiene and cost-effectiveness. (orig.)

  12. Blood Pool Contrast-enhanced Magnetic Resonance Angiography with Correlation to Digital Subtraction Angiography: A Pictorial Review

    Directory of Open Access Journals (Sweden)

    Martha-Grace Knuttinen

    2014-01-01

    Full Text Available Magnetic resonance angiography (MRA provides noninvasive visualization of the vascular supply of soft tissue masses and vascular pathology, without harmful radiation. This is important for planning an endovascular intervention, and helps to evaluate the efficiency and effectiveness of the treatment. MRA with conventional extracellular contrast agents relies on accurate contrast bolus timing, limiting the imaging window to first-pass arterial phase. The recently introduced blood pool contrast agent (BPCA, gadofosveset trisodium, reversibly binds to human serum albumin, resulting in increased T1 relaxivity and prolonged intravascular retention time, permitting both first-pass and steady-state phase high-resolution imaging. In our practice, high-quality MRA serves as a detailed "roadmap" for the needed endovascular intervention. Cases of aortoiliac occlusive disease, inferior vena cava thrombus, pelvic congestion syndrome, and lower extremity arteriovenous malformation are discussed in this article. MRA was acquired at 1.5 T with an 8-channel phased array coil after intravenous administration of gadofosveset (0.03 mmol/kg body weight, at the first-pass phase. In the steady-state, serial T1-weighted 3D spoiled gradient echo images were obtained with high resolution. All patients underwent digital subtraction angiography (DSA and endovascular treatment. MRA and DSA findings of vascular anatomy and pathology are discussed and correlated. BPCA-enhanced MRA provides high-quality first-pass and steady-state vascular imaging. This could increase the diagnostic accuracy and create a detailed map for pre-intervention planning. Understanding the pharmacokinetics of BPCA and being familiar with the indications and technique of MRA are important for diagnosis and endovascular intervention.

  13. Diagnostic value of multislice computed tomography angiography in coronary artery disease: A meta-analysis

    International Nuclear Information System (INIS)

    Sun Zhonghua; Jiang Wen

    2006-01-01

    Purpose: To perform a meta-analysis of the diagnostic value of multislice CT (MSCT) angiography in the detection of coronary artery disease (CAD) when compared to conventional coronary angiography. Materials and methods: A search of PubMed and MEDLINE databases for English literature was performed. Only studies with at least 10 patients comparing MSCT angiography with conventional coronary angiography in the detection of CAD were included. Diagnostic value of MSCT angiography compared to coronary angiography was compared and analyzed at segment-, vessel- and patient-based assessment. Results: 47 studies (67 comparisons) met the criteria and were included in our study. Pooled overall sensitivity, specificity and 95% confidence interval for MSCT angiography in the detection of CAD were 83% (79%, 89%), 93% (91%, 96%) at segment-based analysis; 90% (87%, 94%), 87% (80%, 93%) at vessel-based analysis; and 91% (88%, 95%), 86% (81%, 92%) at patient-based analysis, respectively. Diagnostic accuracy of MSCT angiography in evaluating assessable segments was significantly improved with 64-slice scanners when compared to that with 4- and 16-slice scanners (p < 0.05). Conclusion: Our meta-analysis showed that MSCT angiography has potential diagnostic accuracy in the detection of CAD. Diagnostic performance of MSCT angiography has been significantly improved with the latest 64-slice CT, with resultant high qualitative and quantitative diagnostic accuracy. 16-slice CT was limited in spatial resolution which makes it difficult to perform quantitative assessment of coronary artery stenoses

  14. MR angiography (MRA)

    Energy Technology Data Exchange (ETDEWEB)

    Hasuo, Kanehiro [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1995-12-01

    The primary goal of vascular imaging is the visualization of morphology and hemodynamics. Catheter angiography has been regarded as a gold standard for this purpose. However, MR angiography (MRA) is now increasingly being recognized as an important noninvasive technique for the depiction of vascular diseases and is partially superseding catheter angiography. The author evaluated the usefulness of MRA in the diagnosis of cerebral aneurysms and moyamoya disease. All aneurysms 5 mm or larger in diameter could be detected and most of those less than 5 mm in diameter were also detectable with using a combination of MIP images, target MIP images and source images. In moyamoya disease, the diagnosis could be made in all. For hemodynamic changes, flow directions in the circle of Willis could be visualized by phase-contrast MRA in a normal volunteer. In addition, MRA successfully showed the patency of surgical collaterals in cases of moyamoya disease. Despite some limitations compared with catheter angiography, MRA has a high sensitivity and specificity in the diagnosis of cerebrovascular abnormalities. Furthermore, screening of cerebral aneurysms or cerebrovascular occlusive diseases seems to be a new, and important indication for MRA. (author).

  15. MR angiography of in situ and transplanted renal arteries

    International Nuclear Information System (INIS)

    Smith, H.J.; Bakke, S.J.

    1993-01-01

    Three-dimensional (3D) time-of-flight (TOF) MR angiography (MRA) was performed in 34 patients with suspected renal artery disease. In situ (i.e., nontransplanted) renal arteries were studied with MRA in 14 patients. Of these, 12 had conventional angiography for comparison. Twenty-four MRAs of transplanted renal arteries were obtained in 20 patients; 8 of these had angiography as well. Significant stenoses of in situ renal arteries were diagnosed with a sensitivity of 100% and a specificity of 95%. The stenoses were all proximal; 3D TOF MRA proved inadequate for depiction of peripheral renal arteries. MRA and angiography showed good agreement between findings in 7 of 8 patients with renal transplants. In one patient with a renal transplant, MRA showed a significant stenosis of the arterial anastomosis which appeared completely normal at i.a. DSA, indicating that findings at MRA still need to be confirmed by more established alternative methods. (orig.)

  16. Usefulness of MR angiography in renal tumor

    International Nuclear Information System (INIS)

    Oka, Toshitsugu; Morimoto, Kouji; Nishimura, Kenji; Tsujimura, Akira; Yasunaga, Yutaka; Matsumiya, Kiyomi; Takaha, Minato

    1992-01-01

    MR angiography using a gradient-echo, pulse sequence FLASH (fast, low-angle shot) method during breath-hold with a 'MAGNETOM H-15' scanner (1.5 Tesla; Siemens Medical System) was performed on 27 patients with renal tumor at our clinic between Feburary 20, 1990 and September 30, 1991 and we studied to evaluate its usefulness. Of these 27 patients, 22 patients including one patient under hemodialysis treatment had renal cell carcinoma and one patient had oncocytoma pathologically proven from the excised specimens. The remaining four patients including two patients associated with inferior vena cava tumor thrombus were clinically diagnosed as renal cell carcinoma based on the result of imaging examinations such as excretory urography, ultrasonography, computed tomography and conventional angiography. However, they could not be operated on because their tumors were too advanced. By reconstruction of the data of consecutive coronal scans of the abdominal blood vessels such as the abdominal aorta, inferior vena cava and renal arteries and veins simultaneously without any intravenous contrast materials. Our present study revealed that MR angiography has some advantages, especially with regard to preoperative angiographic information about the abdomen of patients with renal tumor. That is, MR angiography can delineate many kinds of arteries and veins of the abdomen simultaneously and in a broader range, as well as it can be performed on the patients with hypersensitivity to iodinate contrast materials or renal insufficiency in a usual fashion. Furthermore, our present study suggested that the MR angiography is useful for assessing the presence and extent of inferior vena caval tumor thrombus of renal cell carcinoma and for clearly distinguishing tumor lesion and the surrounding normal renal parenchyma in the patients with renal tumor. (author)

  17. Usefulness of MR angiography in renal tumor

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Toshitsugu; Morimoto, Kouji; Nishimura, Kenji; Tsujimura, Akira; Yasunaga, Yutaka; Matsumiya, Kiyomi; Takaha, Minato (Osaka National Hospital (Japan))

    1992-11-01

    MR angiography using a gradient-echo, pulse sequence FLASH (fast, low-angle shot) method during breath-hold with a MAGNETOM H-15 scanner (1.5 Tesla; Siemens Medical System) was performed on 27 patients with renal tumor at our clinic between Feburary 20, 1990 and September 30, 1991 and we studied to evaluate its usefulness. Of these 27 patients, 22 patients including one patient under hemodialysis treatment had renal cell carcinoma and one patient had oncocytoma pathologically proven from the excised specimens. The remaining four patients including two patients associated with inferior vena cava tumor thrombus were clinically diagnosed as renal cell carcinoma based on the result of imaging examinations such as excretory urography, ultrasonography, computed tomography and conventional angiography. However, they could not be operated on because their tumors were too advanced. By reconstruction of the data of consecutive coronal scans of the abdominal blood vessels such as the abdominal aorta, inferior vena cava and renal arteries and veins simultaneously without any intravenous contrast materials. Our present study revealed that MR angiography has some advantages, especially with regard to preoperative angiographic information about the abdomen of patients with renal tumor. That is, MR angiography can delineate many kinds of arteries and veins of the abdomen simultaneously and in a broader range, as well as it can be performed on the patients with hypersensitivity to iodinate contrast materials or renal insufficiency in a usual fashion. Furthermore, our present study suggested that the MR angiography is useful for assessing the presence and extent of inferior vena caval tumor thrombus of renal cell carcinoma and for clearly distinguishing tumor lesion and the surrounding normal renal parenchyma in the patients with renal tumor. (author).

  18. Global ejection fraction and phase analysis assessed by radionuclide angiography during exercise and after isoproterenol infusion

    International Nuclear Information System (INIS)

    Righetti, A.; Ratib, O.; Merier, G.; Widmann, T.; Donath, A.

    1983-01-01

    Radionuclide angiography obtained during and following Isoproterenol infusion is a new approach for detecting latent myocardial ischemia. It is very sensitive and could be considered as an alternative to conventional exercice radionuclide angiography. The data presented show that phase analysis assessment of regional systolic wall motion is a better indicator than global ejection fraction for quantifying left ventricular dysfunction

  19. Intravenous coronary angiography by electron beam computed tomography : a clinical evaluation

    NARCIS (Netherlands)

    Rensing, B J; Bongaerts, A; van Geuns, R J; van Ooijen, P; Oudkerk, M; de Feyter, P J

    1998-01-01

    BACKGROUND: -Noninvasive detection of coronary stenoses with electron beam CT (EBCT) after intravenous injection of contrast medium has recently emerged. We sought to determine the diagnostic accuracy of EBCT angiography in the clinical setting using conventional coronary angiography as the "gold

  20. Evaluation of the pedal artery: comparison of three-dimensional gadolinium-enhanced MR angiography with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Kang, Sung Gwon; Byun, Joo Nam; Kim, Young Cheol; Choi, Jeong Yeol; Kim, Dong Hyun [College of Medicine, Chosun Univ., Kwangju (Korea, Republic of)

    2002-07-01

    To compare the three-dimensional gadolinium-enhanced MR angiography with digital subtraction angiography (DSA) for evaluation of the pedal artery. In 12 extremities of 11 patients, both digital subtraction angiography (DSA) and contrast-enhanced MR angiography (CE-MR angiography) were performed during the same week. Among ten of the 11 patients, the following conditions were present: atherosclerosis (n=4), diabetic foot (n=3), Buerger's disease (n=1), calciphylactic arteriopathy (n=1) and arteriovenous malformation of the foot (n=1). The remaining patient underwent angiography prior to flap surgery. For MR angiography, a 1.5T system using an extremity or head coil was used. A three-dimensional FISP (fast imaging with steady state precession) sequence was obtained before enhancement, followed by four sequential acquisitions (scan time, 20 secs, scan interval time, 10 secs) 10 seconds after intravenous bolus injection of normal saline (total 10 cc), following intravenous administration of gadolinium (0.02 mmol/kg, 3 ml/sec). Arterial segments of the ankle and foot were classified as the anterior or posterior tibial artery, the distal peroneal artery, the medial or lateral plantar artery, the pedal arch, and the dorsalis pedis artery. Two radiologists independently analysed visualization of each arteraial segment and the mean of visible arterial segments in one extreminty using CE-MR angiography and DSA. Among 84 arterial segments, 16 were invisible at both CE-MR angiography and DSA, while 39 were demonstrated by both modalities. Twenty-six segments were visible only at CE-MR angiography and three only at DSA. CE-MR angiography displayed a higher number of arterial segments than DSA (mean, 5.42 vs. mean 3.50, respectively), a difference which was statistically significant (p<0.000). The difference between each arterial segment was not statistically significant, except for the dorsalis pedis artery (t test, p<0.000). In that it provides additional information for

  1. The potential for neurovascular intravenous angiography using K-edge digital subtraction angiography

    International Nuclear Information System (INIS)

    Schueltke, E.; Fiedler, S.; Kelly, M.; Griebel, R.; Juurlink, B.; LeDuc, G.; Esteve, F.; Le Bas, J.-F.; Renier, M.; Nemoz, C.; Meguro, K.

    2005-01-01

    Background: Catheterization of small-caliber blood vessels in the central nervous system can be extremely challenging. Alternatively, intravenous (i.v.) administration of contrast agent is minimally invasive and therefore carries a much lower risk for the patient. With conventional X-ray equipment, volumes of contrast agent that could be safely administered to the patient do not allow acquisition of high-quality images after i.v. injection, because the contrast bolus is extremely diluted by passage through the heart. However, synchrotron-based digital K-edge subtraction angiography does allow acquisition of high-quality images after i.v. administration of relatively small doses of contrast agent. Materials and methods: Eight adult male New Zealand rabbits were used for our experiments. Animals were submitted to both angiography with conventional X-ray equipment and synchrotron-based digital subtraction angiography. Results: With conventional X-ray equipment, no contrast was seen in either cerebral or spinal blood vessels after i.v. injection of iodinated contrast agent. However, using K-edge digital subtraction angiography, as little as 1 ml iodinated contrast agent, when administered as i.v. bolus, yielded images of small-caliber blood vessels in the central nervous system (both brain and spinal cord). Conclusions: If it would be possible to image blood vessels of the same diameter in the central nervous system of human patients, the synchrotron-based technique could yield high-quality images at a significantly lower risk for the patient than conventional X-ray imaging. Images could be acquired where catheterization of feeding blood vessels has proven impossible

  2. CT and MR angiography

    International Nuclear Information System (INIS)

    Bert, A.L.; Marshal, G.

    1995-01-01

    CT-angiography is a new vessel imaging technique based on the volumetric scanning of the region of interst during the first pass of IV bolus injection of contrast medium. MR-angiography is a titally noninvasive technique. The differentiation of flowing blood from the adjecent stationary tissues is based on the detection of blood motion. The flowing blood is highlighted with white light. CT- and MR-angiographic techniques are used to establish% stenoses and occlusions in intracranial arteries; aneurisms; trombosis of intracranial veins and venous angioma; diseases of neck vessels, thoracic vessels, abdominal vessels. Blood flow direction in cirrotic patients with portal hypertension can be determined in the portal vein, as well as the presence of thrombosis

  3. Digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Ludwig, J.W.; Eikelboom, B.C.; Van Schaik, C.C.; Taams, A.J.; Teeuwen, C.

    1985-01-01

    Besides the non-invasive techniques, angiography remains essential. The disadvantages of angiography are the complexity of the procedure and the possibility of complications. Digital subtraction angiography (DSA) is a considerable improvement in the examination of vessels. In DSA, subtraction combined with enhancement of the signals allows the use of intravenous injection to obtain good images of the arteries. However, when the contrast material is supplied intravenously, a rather large amount of contrast material is necessary to obtain images of good quality. Quantities of 30-40 cc of contrast material are required. The advantage of the intravenous injection of contrast material rather than the use of a catheter to deliver the contrast material in loco is that it is almost non-invasive thus circumventing the complications caused by catheter manipulation in the arterial system. This makes it possible to apply this method on an out-patient basis. DSA can also be applied with intra-arterial selective injection of the contrast material. In this case, the strong enhancement with DSA allows the use of a small quantity of contrast material while still obtaining images of the vessels with good contrast definition

  4. Angiography in renal tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Doo Suk [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1974-10-15

    Angiographies on forty cases of renal tuberculosis performed at the National Medical Center during a period 1960 through 1970 were reviewed. Abdominal angiography was performed via the femoral route. Some were followed by selective nephroangiography. All patients were subjected to urographyior to angiography. The results of X-ray findings in the forty cases with renal tuberculosis were follows. 1. The age varied 18 to 57 years, average 30.5 years. Twenty one patients were male, and nineteen were female. 2. The right kidney was involved in 17 cases and the left in 15 cases. Both kidneys were involved in 8 cases. 3. Urographic examination revealed pathologic changes in all patients. 4. Focal destruction in the collecting system was the most common finding in the urography of 16 patients. 5. A varying degree of hydronephrosis was present in 15 patients, of whom nine had complained of palpable mass due to hydronephrosis. 6. In the 7 patients with extensive destruction there was no observable excretion contrast medium from the diseased kidney. 7. Angiographic examination was normal in 6 of the 40 patients. 8. Decreased vascularity in the subsegmental or smaller arteries of the affected kidney was the most frequent finding, being found in 34 patients. 9. Occlusion or abrupt termination of the subsegmental arteries was present in 4 patients. 10. Eighteen of the patients had signs of an expansive process within the cavity, the vessels being displaced and stretched around the lesions.

  5. Assessment of extracranial-intracranial bypass patency with 64-slice multidetector computerized tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Thines, Laurent [Lille University Hospital, Department of Neurosurgery, Lille (France); Toronto Western Hospital, Division of Neurosurgery and Department of Surgery, Toronto, ON (Canada); Toronto Western Hospital, University of Toronto Brain Vascular Malformation Study Group, Toronto, ON (Canada); Agid, Ronit; Da Costa, Leodante; Terbrugge, Karel G. [Toronto Western Hospital, Division of Neuroradiology, Department of Medical Imaging, Toronto, ON (Canada); Toronto Western Hospital, University of Toronto Brain Vascular Malformation Study Group, Toronto, ON (Canada); Dehdashti, Amir R.; Wallace, M.C.; Tymianski, Michael [Toronto Western Hospital, Division of Neurosurgery and Department of Surgery, Toronto, ON (Canada); Toronto Western Hospital, University of Toronto Brain Vascular Malformation Study Group, Toronto, ON (Canada)

    2009-08-15

    Extracranial-intracranial (EC/IC) bypass is a useful procedure for the treatment of cerebral vascular insufficiency or complex aneurysms. We explored the role of multidetector computed tomography angiography (MDCTA), instead of digital subtraction angiography (DSA), for the postoperative assessment of EC/IC bypass patency. We retrospectively analyzed a consecutive series of 21 MDCTAs from 17 patients that underwent 25 direct or indirect EC/IC bypass procedures between April 2003 and November 2007. Conventional DSA was available for comparison in 13 cases. MDCTA used a 64-slice MDCT scanner (Aquilion 64, Toshiba). The proximal and distal patencies were analyzed independently on MDCTA and DSA by a neuroradiologist and a neurosurgeon. The bypass was considered patent when the entire donor vessel was opacified without discontinuity from proximal to distal ends and was visibly in contact with the recipient vessel. MDCTA depicted the patency status in every patient. Bypasses were patent in 22 cases, stenosed in one, and occluded in two. DSA always confirmed the results of the MDCTA (sensitivity = 100%, 95% CI = 0.655-1.0; specificity 100%, 95% CI = 0.05-1.0). MDCTA is a non-invasive and accurate exam to assess the postoperative EC/IC bypass patency and is a promising technique in routine follow-up. (orig.)

  6. Diagnostic performance of 320-detector CT coronary angiography in patients with atrial fibrillation: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Lei; Yang, Lin; Fan, Zhanming; Yu, Wei; Lv, Biao; Zhang, Zhaoqi [Capital Medical University, Department of Radiology, Beijing Anzhen Hospital, Beijing (China)

    2011-05-15

    To evaluate the feasibility, diagnostic accuracy, and radiation dose of CT coronary angiography (CTCA) in patients with atrial fibrillation (AF) using 320-detector CT. Thirty-seven patients with persistent AF and suspected coronary artery disease (CAD) were enrolled. All patients underwent both 320-detector CTCA and conventional coronary angiography (CCA). CT image quality and the presence of significant ({>=}50%) stenosis were evaluated by two radiologists blinded to the results of CCA. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated using CCA as the reference standard. Differences in detection of coronary artery stenosis between 320-detector CTCA and CCA were evaluated with McNemar's test. Patient radiation dose was calculated by multiplying dose length product by conversion coefficient of 0.017. In total 474 evaluated coronary segments, 459 (96.8%) segments were diagnostically evaluable. On per-segment analysis, sensitivity, specificity, PPV and NPV were 90.0% (18 of 20), 99.3% (436 of 439), 85.7% (18 of 21) and 99.5% (436 of 438). No significant difference was found between 320-detector CTCA and CCA on the detection of significant stenosis (P = 1.000). Effective doses of 320-detector CTCA was 13.0 {+-} 4.7 mSv. 320-detector CTCA is feasible and accurate in excluding CAD in patients with AF. (orig.)

  7. Bolus timing in high-pitch CT angiography of the aorta

    International Nuclear Information System (INIS)

    Beeres, Martin; Loch, Matthias; Schulz, Boris; Kerl, Matthias; Al-Butmeh, Firas; Bodelle, Boris; Herrmann, Eva; Gruber-Rouh, Tatjana; Lee, Clara; Jacobi, Volkmar; Vogl, Thomas J.

    2013-01-01

    Objective: To investigate the bolus geometry in high-pitch CT angiography (CTA) of the aorta without ECG synchronisation in comparison to single-source CT. Methods: Overall 160 consecutive patients underwent CTA either in conventional single-source mode with a pitch of 1.2 (group 1), or in dual-source mode with a pitch of 3.0 (groups 2, 3 and 4) using different contrast media timings with bolus triggering at 140 HU (5 s, group 1; 10 s, group 2; 12 s, group 3; 14 s, group 4). Contrast material, saline flush, flow rate and kV/mAs settings were kept equal for optimum comparability. Aortic attenuation was measured along the z-axis of the patient at different anatomic landmarks and subjective image quality was compared. Results: The most homogeneous enhancement of the aorta was reached with a delay of 10 s after reaching the trigger threshold. The imaging length was not significantly different, but the examination time was significantly (p < 0.001) shorter in the high-pitch group (7.7 s vs. 1.7 s for group 1 vs. 2, 3 and 4). Conclusion: In high-pitch CT angiography using a start delay of 10 s after a trigger threshold of 140 HU in the descending aorta is reached, a homogenous contrast along the z-axis is accomplished

  8. Angiography and the gastrointestinal bleeder

    International Nuclear Information System (INIS)

    Baum, S.

    1982-01-01

    The role of angiography in the diagnosis and treatment of gastrointestinal hemorrhage is discussed. Three categories of gastrointestinal bleeding are considered: upper gastrointestinal bleeding due to gastroesophageal varices, upper gastrointestinal bleeding of arterial or capillary origin, and lower gastrointestinal bleeding. The advantages and disadvantages of angiography are compared with those of radionuclide scanning and endoscopy or colonoscopy. It is anticipated that, as radionuclide scans are more widely employed, angiography will eventually be performed only in those patients with positive scans

  9. Clinical experience of magnetic resonance angiography in hand surgery

    International Nuclear Information System (INIS)

    Kawabata, Hidehiko; Yasui, Natsuo; Kitano, Motohiro; Sai, Eikoh

    1996-01-01

    Magnetic resonance angiography was performed in fourteen patients with congenital hand abnormalities. A two-dimentional time-of-flight imaging clearly demonstrated presence or absence of the radial, ulnar, and anterior interosseous arteires at forearm. However, smaller arteries such as digital arteries were depressed sometimes. This fact makes clinical application of the method somewhat limited. At present. appropriate applications in orthopaedic fields are evaluation of run-off of the major vessels after trauma or atherosclerotic diseases, venous vascular problems such as thrombophlebitis and aneurysm, and preoperative and post operative evaluation in microsurgery. If more detailed information is required, for example, in differential diagnosis of tumors conventional angiography or digital subtraction angiography is recommended. Because magnetic resonance angiography is non-invasive and does not need anesthesia, it is suitable especially for children. No requirement of contrast medium makes it easy to apply angiography to high risk patients and allergic patients to iodine. Technical advancement in near future will rise up magnetic resonance angiography to a standard evaluation method for vascular problems in orthopaedic fields very soon. (author)

  10. Comparison of gadofosveset-enhanced three-dimensional magnetic resonance angiography with digital subtraction angiography for lower-extremity peripheral arterial occlusive disease

    International Nuclear Information System (INIS)

    Grijalba, Fermin Urtasun; Esandi, Mercedes Ciriza

    2010-01-01

    Background: Minimally invasive imaging techniques are increasingly used for clinical decision making in patients with peripheral arterial occlusive disease (PAOD). Purpose: To assess whether gadofosveset-enhanced three-dimensional (3D) magnetic resonance (MR) angiography could replace digital subtraction angiography (DSA) for the evaluation of lower-extremity PAOD. Material and Methods: Thirty patients with symptomatic PAOD underwent prospectively both MR angiography and DSA. Gadofosveset-enhanced 3D MR angiography was performed on a 1.5T system equipped with a peripheral angio matrix coil. Four blinded observers independently analyzed MR angiograms and DSA images. The lower arterial vascular system was divided into three anatomic segments (aortoiliac, femoropopliteal, infrapopliteal) for review. The status of each segment was graded as normal, stenosis less than 50%, stenosis greater than 50%, or occluded and/or aneurismatic. Principal and secondary lesions were reported. Results: Although interobserver agreement for both was excellent, it was higher for DSA (?=0.92) than for MR angiography (?=0.86) for reporting the principal and secondary lesions in all segments. For different anatomic locations, the interobserver agreement of MR angiography and DSA was as follows: aortoiliac (?=0.93, k=0.95), femoropopliteal (?=0.86, k=0.90), and infrapopliteal (?=0.78, k=0.85). The lowest agreement was found for MR angiography on infrapopliteal segments (?=0.78). In four (13.3%) cases, MR angiography showed lesions that were not found by DSA. Five (16.6%) aneurysm cases, not observed by DSA, were shown by MR angiography. Conclusion: Gadofosveset-enhanced 3D MR angiography can be proposed for first-line imaging in the management of lower-limb PAOD patients and permits the selective use of DSA as a second-line examination when MR angiography fails or in an endovascular approach

  11. Pure and diluted contrast medium in the evaluation of portal venous system with digital subtraction angiography

    International Nuclear Information System (INIS)

    Gattoni, F.; Baldini, V.; Pozzato, C.; Nessi, R.; Raiteri, R.; Uscenghi, C.; Opocher, E.; Santambrogio, R.

    1990-01-01

    We report the results of intra-arterial digital subtraction angiography (DSA) in 100 patients with portal hypertension. The portal venous system was evaluated; all patients underwent angiography of the celiac and superior mesenteric arteries before surgery. Forty-four of them were also examined after Warren splenorenal shunts. Therefore, a total of 144 exams was evaluated. The authors always employed low-osmolality ionic and non-ionic contrast media (iodine concentration: 300-350 mg/ml). In 70 cases pure contrast medium was injected (20/25 ml): in the extant 74 cases it was diluted with an equal volume of saline solution (osmolality and iodine concentration reduced by 50%). Intra-arterial DSA always visualized portal venous system, collateral circulation, shunt location and postoperative changes. The mayor advantage of intra-arterial DSA is the smaller amount of contrast medium injected, so that local and systemic side effects are rare. According to our experience, it is best to dilute the contrast medium and inject the same amount as in conventional angiography, at the same rate. Other well-known advantages of intra-arterial DSA are quicker execution, less injury to arteries using smaller caliber catheters, and low cost. The major disadvantage of intra-arterial DSA, as it appeared also in our study, is the field size of the intensifier, which in our case was limited to 6-9 inches. This is an insufficient coverage for the whole portal system to be studied, and some contrast medium injections become therefore necessary. An average of 3 injections were given to each patient. This problem reduces the advantage of less contrast medium per injection. At any rate, even though intra-arterial DSA exhibits this limitation, it can nevertheless yield important information in the pre- and postoperative evaluation of patients with portal hypertension

  12. Evaluation of intracranial arteriovenous malformations before and after embolization with dynamic MR digital subtraction angiography

    International Nuclear Information System (INIS)

    Chen Shuang; Feng Xiaoyuan; Baleriaux, D.; Metens, T.

    2005-01-01

    Objective: To evaluate the clinical utility and accuracy of dynamic MR digital subtraction angiography (MR-DSA) in the detection of intracranial arteriovenous malformations before and after embolization. Methods: A prospective blinded comparison of MR-DSA, 3D contrast-enhanced T 1 -weighted MR angiography (3D-CEMRA), proton-weighted imaging and conventional digital subtraction angiography (DSA) were underwent in 22 consecutive AVMs patients before and after embolization. Two readers independently interpreted images and compared with DSA images. Results: There was complete agreement between MR-DSA and DSA for classification and size of nidus before and after embolization in all cases. MR-DSA showed the modified hemodynamic features (the time of nidus, early venous enhancement delayed after carotid arteries appearance) in 17 cases, and nidus size were reduced in 13 cases (including 4 complete embolized cases) after embolization, which were 100% consistence compared with DSA. MR-DSA failed to depict 1 intranidal aneurysm and missed 1 less dilated artery and draining vein after embolization respectively, which were demonstrated clearly by 3D-CEMRA confirmed with DSA. The relatively more or less hyperintensity could be seen on proton-weighted imaging in all cases after embolization than before. Conclusion: MR-DSA is a fast, efficient, and noninvasive technique to provide hemodynamic information relevant for AVMs before and after embolization. Proton imaging is sensitive in delineation of the embolized region, MR-DSA, 3D-CEMRA and proton-weighted imaging should be combined in the evaluation and follow-up AVMs after partial embolization. (authors)

  13. Postmortem CT Angiography Compared with Autopsy: A Forensic Multicenter Study.

    Science.gov (United States)

    Grabherr, Silke; Heinemann, Axel; Vogel, Hermann; Rutty, Guy; Morgan, Bruno; Woźniak, Krzysztof; Dedouit, Fabrice; Fischer, Florian; Lochner, Stefanie; Wittig, Holger; Guglielmi, Giuseppe; Eplinius, Franziska; Michaud, Katarzyna; Palmiere, Cristian; Chevallier, Christine; Mangin, Patrice; Grimm, Jochen M

    2018-05-01

    Purpose To determine if postmortem computed tomography (CT) and postmortem CT angiography help to detect more lesions than autopsy in postmortem examinations, to evaluate the strengths and weaknesses of each method, and to define their indications. Materials and Methods Postmortem CT angiography was performed on 500 human corpses and followed by conventional autopsy. Nine centers were involved. All CT images were read by an experienced team including one forensic pathologist and one radiologist, blinded to the autopsy results. All findings were recorded for each method and categorized by anatomic structure (bone, organ parenchyma, soft tissue, and vascular) and relative importance in the forensic case (essential, useful, and unimportant). Results Among 18 654 findings, autopsies helped to identify 61.3% (11 433 of 18 654), postmortem CT helped to identify 76.0% (14 179 of 18 654), and postmortem CT angiography helped to identify 89.9% (16 780 of 18 654; P < .001). Postmortem CT angiography was superior to autopsy, especially at helping to identify essential skeletal lesions (96.1% [625 of 650] vs 65.4% [425 of 650], respectively; P < .001) and vascular lesions (93.5% [938 of 1003] vs 65.3% [655 of 1003], respectively; P < .001). Among the forensically essential findings, 23.4% (1029 of 4393) were not detected at autopsy, while only 9.7% (428 of 4393) were missed at postmortem CT angiography (P < .001). The best results were obtained when postmortem CT angiography was combined with autopsy. Conclusion Postmortem CT and postmortem CT angiography and autopsy each detect important lesions not detected by the other method. More lesions were identified by combining postmortem CT angiography and autopsy, which may increase the quality of postmortem diagnosis. Online supplemental material is available for this article.

  14. New electronic filtering technique in digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Stacul, F; Pozzi-Mucelli, R; Predonzan, F; Magnaldi, S; Godina, G

    1986-01-01

    The authors report their experience with a new electronic filtering technique in digital subtraction angiography (DSA). The principles of the technique are reported and the advantages in comparison with conventional filters are stressed (accurate and fast placement without fluoroscopic exposure). The system provided excellent results in about 900 DSA examinations.

  15. Optical Coherence Tomography Angiography in Retinal Diseases.

    Science.gov (United States)

    Chalam, K V; Sambhav, Kumar

    2016-01-01

    Optical coherence tomography angiography (OCTA) is a new, non-invasive imaging system that generates volumetric data of retinal and choroidal layers. It has the ability to show both structural and blood flow information. Split-spectrum amplitude-decorrelation angiography (SSADA) algorithm (a vital component of OCTA software) helps to decrease the signal to noise ratio of flow detection thus enhancing visualization of retinal vasculature using motion contrast. Published studies describe potential efficacy for OCTA in the evaluation of common ophthalmologic diseases such as diabetic retinopathy, age related macular degeneration (AMD), retinal vascular occlusions and sickle cell disease. OCTA provides a detailed view of the retinal vasculature, which allows accurate delineation of microvascular abnormalities in diabetic eyes and vascular occlusions. It helps quantify vascular compromise depending upon the severity of diabetic retinopathy. OCTA can also elucidate the presence of choroidal neovascularization (CNV) in wet AMD. In this paper, we review the knowledge, available in English language publications regarding OCTA, and compare it with the conventional angiographic standard, fluorescein angiography (FA). Finally, we summarize its potential applications to retinal vascular diseases. Its current limitations include a relatively small field of view, inability to show leakage, and tendency for image artifacts. Further larger studies will define OCTA's utility in clinical settings and establish if the technology may offer a non-invasive option of visualizing the retinal vasculature, enabling us to decrease morbidity through early detection and intervention in retinal diseases.

  16. New aspects in the diagnosis of angina abdominalis using digital substraction angiography

    International Nuclear Information System (INIS)

    Mahmalat, M.O.; Beyer, H.K.

    1985-01-01

    Selective intra-arterial digital substraction angiography (DSA) is important in the demonstration of the visceral abdominal vessels in angina-abdominalis patients. DSA allows to accurately determine the location of stenoses, vascular occlusions or plaque formations as does conventional angiography; in addition, it provides for simultaneous direct observation which is a major advantage over the conventional technique since suspected lesions can be better focussed in several planes. (orig.) [de

  17. Contrast-enhanced three-dimensional fast-spoiled gradient magnetic resonance angiography of the renal arteries for potential living renal transplant donors: a comparative study with digital subtraction angiography

    International Nuclear Information System (INIS)

    Al-Saeed, O.; Sheikh, M.; Al-Khawari, H.; Ismail, M.; Al-Moosawi, M.

    2005-01-01

    Preoperative assessment of the arterial anatomy of prospective renal donors is essential. Various non-invasive techniques are used for such evaluation. We conducted this study using contrast-enhanced 3-D fast-spoiled gradient (CE 3-D FSPGR) magnetic resonance angiography (MRA) on a 1.0 Tesla magnet, for preoperative definition of the renal arteries. Forty-five preoperative living renal donors underwent CE 3-D FSPGR MRA of the renal vessels and the results were compared with conventional digital subtraction angiography (DSA). The renal vascular anatomy, both normal and with variations, was satisfactorily defined in all 45 cases with CE 3-D FSPGR MRA. Fifteen cases showed an accessory or aberrant arterial supply. A small aneurysm was shown in one case. All cases compared well with conventional DSA. Our study revealed that CE 3-D FSPGR MRA on a lower field strength magnet is accurate in defining the renal vascular anatomy and its variations. Copyright (2005) Blackwell Science Pty Ltd

  18. Digital subtraction angiography in cardiac diseases

    International Nuclear Information System (INIS)

    Choi, Deuk Lin; Kim, Ki Jeong

    1986-01-01

    DSA was done in 133 examinations of 128 patients during 2 years consist of 9 examination of IV DSA and 124 examination of selective cardiac DSA after cardiac catheterization. Open heart surgery was performed in 90 patients and 12 patients showed discrepancy between pre-and post operative diagnosis, showing a total 86.7% of diagnostic accuracy with DSA. We experienced the significant reduction in dose of contrast media, 30-40% of dose of conventional cardiac angiography. It is concluded that DSA is useful in the evaluation of septal defects, valvular disease and other congenital heart disease. DSA is an accurate simple and safe method in evaluating of cardiac diseases.

  19. Nonenhanced MR angiography techniques

    International Nuclear Information System (INIS)

    Lanzman, R.S.; Kroepil, P.; Blondin, D.; Schmitt, P.

    2011-01-01

    Especially in regard to the potential risks for the development of nephrogenic systemic fibrosis (NSF) following the administration of Gadolinium-based contrast material, nonenhanced MR angiography (MRA) methods are becoming ever more important. Besides well-established time-of-flight (TOF) and phase-contrast (PC) MRA, alternative imaging techniques based on balanced steady-state free precession (bSSFP) and turbo-spin-echo (TSE) sequences are increasingly used in combination with or without arterial spin labeling (ASL) strategies. This article provides an overview of the principles and clinical values of different nonenhanced MRA techniques. In addition, recent nonenhanced MRA developments are presented. (orig.)

  20. Hepatic Artery Angiography and Embolization for Hemobilia Following Laparoscopic Cholecystectomy

    International Nuclear Information System (INIS)

    Nicholson, Tony; Travis, Simon; Ettles, Duncan; Dyet, John; Sedman, Peter; Wedgewood, Kevin; Royston, Christopher

    1999-01-01

    Purpose: The effectiveness of angiography and embolization in diagnosis and treatment were assessed in a cohort of patients presenting with upper gastrointestinal hemorrhage secondary to hepatic artery pseudoaneurysm following laparoscopic cholecystectomy. Methods: Over a 6-year period 1513 laparoscopic cholecystectomies were carried out in our region. Nine of these patients (0.6%) developed significant upper gastrointestinal bleeding, 5-43 days after surgery. All underwent emergency celiac and selective right hepatic artery angiography. All were treated by coil embolization of the right hepatic artery proximal and distal to the bleeding point. Results: Pseudoaneurysms of the hepatic artery adjacent to cholecystectomy clips were demonstrated in all nine patients at selective right hepatic angiography. In three patients celiac axis angiography alone failed to demonstrate the pseudoaneurysm. Embolization controlled hemorrhage in all patients with no further bleeding and no further intervention. One patient developed a candidal liver abscess in the post-procedure period. All patients are alive and well at follow-up. Conclusion: Selective right hepatic angiography is vital in the diagnosis of upper gastrointestinal hemorrhage following laparoscopic cholecystectomy. Embolization offers the advantage of minimally invasive treatment in unstable patients, does not disrupt recent biliary reconstruction, allows distal as well as proximal control of the hepatic artery, and is an effective treatment for this potentially life-threatening complication

  1. Multislice computed tomographic coronary angiography: experience in a UK centre

    International Nuclear Information System (INIS)

    Morgan-Hughes, G.J.; Marshall, A.J.; Roobottom, C.A.

    2003-01-01

    AIM: To evaluate the technique of coronary angiography with retrospectively electrocardiogram (ECG)-gated four-slice helical computed tomography (CT). MATERIALS AND METHODS: Within 1 month of undergoing routine day-case diagnostic coronary angiography, 30 consecutive patients also underwent retrospectively ECG-gated multislice CT coronary angiography. This enabled direct comparison of seven segments of proximal and mid-coronary artery for each patient by two blinded assessors. Each segment of coronary artery from the multislice CT image was evaluated initially for 'assessability' and those segments deemed assessable were subsequently investigated for the presence or absence of a significantly (n=70%) stenotic lesion. RESULTS: Overall 68% of proximal and mid-coronary artery segments were assessable. The sensitivity and specificity of four-slice CT coronary angiography in assessable segments for detecting the presence or absence (n=70%) of stenoses were 72 and 86%, respectively. These results correspond to a positive predictive value of 53% and a 93% negative predictive value. If the 32% of non-assessable segments are added into the calculation then the sensitivity and specificity fall to 49 and 66%, respectively. CONCLUSION: Although multislice CT coronary angiography is a promising technique, the overall assessability and diagnostic accuracy of four-slice CT acquisition is not sufficient to justify routine clinical use. Further, evaluation should investigate the benefit of the reduction in temporal and spatial resolution offered by 16 and 32 slice acquisition

  2. Comparing treatment outcomes of fractional flow reserve-guided and angiography-guided percutaneous coronary intervention in patients with multi-vessel coronary artery diseases: a systematic review and meta-analysis.

    Science.gov (United States)

    Xiu, Jiancheng; Chen, Gangbin; Zheng, Hua; Wang, Yuegang; Chen, Haibin; Liu, Xuewei; Wu, Juefei; Bin, Jianping

    2016-02-01

    Fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) is used to assess the need for angioplasty in vessels with intermediate blockages. The treatment outcomes of FFR-guided vs. conventional angiography-guided PCI were evaluated in patients with multi-vessel coronary artery disease (CAD). Prospective and retrospective studies comparing FFR-guided vs. angiography-guided PCI in patients with multi-vessel CAD were identified from medical databases by two independent reviewers using the terms "percutaneous coronary intervention, fractional flow reserve, angiography, coronary heart disease, major adverse cardiac events (MACE) and myocardial infarction". The primary outcome was the number of stents placed, and the secondary outcomes were procedure time, mortality, myocardial infarction (MI) and MACE rates. Seven studies (three retrospective and four prospective), which included 49,517 patients, were included in this review. A total of 4,755 patients underwent FFR, while 44,697 received angiography-guided PCI. The mean patient age ranged from 58 to 71.7 years. The average number of stents used in FFR patients ranged from 0.3-1.9, and in angiography-guided PCI patients ranged from 0.7-2.7. Analysis indicated there was a greater number of stents placed in the angiography-guided group compared with the FFR group (pooled difference in means: -0.64, 95% confidence interval [CI]: -0.81 to -0.47, P < 0.001). There were no differences in the secondary outcomes between the two groups. Both procedures produce similar clinical outcomes, but the fewer number of stents used with FFR may have clinical as was as cost implications.

  3. The impact of exercise myocardial perfusion SPECT imaging on the selection of patients for coronary angiography

    International Nuclear Information System (INIS)

    Song Liping; He Zuoxiang; Liu Xiujie; Shi Rongfang; Liu Yunzhong; Tian Yueqin; Zhang Xiaoli; Qin Xuewen; Chen Jilin; Gao Runlin

    2001-01-01

    Objective: Exercise 99 Tc m -MIBI myocardial perfusion SPECT is accurate for the diagnosis of coronary artery disease (CAD). This study assessed the impact of exercise myocardial perfusion imaging on the selection of patients for coronary angiography. Methods: 2188 consecutive patients who underwent exercise myocardial perfusion SPECT in authors' department in 1999 were retrospectively analyzed. Among them, 1807 were men, 381 women (average age: 53.5 +- 7.2 years). Overall, exercise myocardial SPECT was normal in 1731 patients, abnormal in 359 cases, and equivocal in 98 patients. There were 141 patients who underwent CAG within 60 days after myocardial SPECT. Results: Overall, 12% of the patients with abnormal SPECT imaging underwent coronary angiography, but only 5% of the patients with a normal SPECT imaging did (P < 0.001). Among these 141 patients who underwent coronary angiography, significant coronary stenosis was present in 91% of the patients who had had an abnormal SPECT imaging, but only 8% of those who had had a normal SPECT imaging (P < 0.001). In those patients who underwent coronary angiography, revascularization rate was 25% for the patients with abnormal SPECT imaging, but only 1% for the patients with a normal SPECT imaging. Conclusion: The results of exercise myocardial perfusion SPECT have a significant impact on the selection of patients for coronary angiography and revascularization

  4. Acute myocardial infarctation in patients with critical ischemia underwent lower limb revascularization

    Directory of Open Access Journals (Sweden)

    Esdras Marques Lins

    2013-12-01

    Full Text Available BACKGROUND: Atherosclerosis is the main cause of peripheral artery occlusive disease (PAOD of the lower limbs. Patients with PAOD often also have obstructive atherosclerosis in other arterial sites, mainly the coronary arteries. This means that patients who undergo infrainguinal bypass to treat critical ischemia have a higher risk of AMI. There are, however, few reports in the literature that have assessed this risk properly. OBJECTIVE: The aim of this study was to determine the incidence of acute myocardial infarction in patients who underwent infrainguinal bypass to treat critical ischemia of the lower limbs caused by PAOD. MATERIAL AND METHODS: A total of 64 patients who underwent 82 infrainguinal bypass operations, from February 2011 to July 2012 were studied. All patients had electrocardiograms and troponin I blood assays during the postoperative period (within 72 hours. RESULTS: There were abnormal ECG findings and elevated blood troponin I levels suggestive of AMI in five (6% of the 82 operations performed. All five had conventional surgery. The incidence of AMI as a proportion of the 52 conventional surgery cases was 9.6%. Two patients died. CONCLUSION: There was a 6% AMI incidence among patients who underwent infrainguinal bypass due to PAOD. Considering only cases operated using conventional surgery, the incidence of AMI was 9.6%.

  5. Digital subtraction angiography in head and neck radiology

    International Nuclear Information System (INIS)

    Carmody, R.F.; Seeger, J.F.; Smith, R.L.; Horsley, W.W.; Miller, R.W.

    1984-01-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 44 patients with suspected otolaryngologic abnormalities. Sixteen had IVDSA for pulsatile tinnitus or suspected glomus tumor of the petrous bone. Nine patients were evaluated because of pulsatile neck masses, and 12 others had suspected tumors of the neck, face, and paranasal sinuses. Seven had IVDSA following head and neck trauma. The technique of examination is described. The current indications of IVDSA in head and neck radiology are discussed. It is concluded that IVDSA is a suitable substitute for conventional angiography for many otolaryngologic conditions and, because of its safety, can be used more liberally. (orig.)

  6. Digital subtraction angiography in head and neck radiology

    Energy Technology Data Exchange (ETDEWEB)

    Carmody, R F; Seeger, J F; Smith, R L; Horsley, W W; Miller, R W

    1984-07-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 44 patients with suspected otolaryngologic abnormalities. Sixteen had IVDSA for pulsatile tinnitus or suspected glomus tumor of the petrous bone. Nine patients were evaluated because of pulsatile neck masses, and 12 others had suspected tumors of the neck, face, and paranasal sinuses. Seven had IVDSA following head and neck trauma. The technique of examination is described. The current indications of IVDSA in head and neck radiology are discussed. It is concluded that IVDSA is a suitable substitute for conventional angiography for many otolaryngologic conditions and, because of its safety, can be used more liberally.

  7. Application of longitudinal magnification effect to magnification stereoscopic angiography. A new method of cerebral angiography

    International Nuclear Information System (INIS)

    Doi, K.; Rossmann, K.; Duda, E.E.

    1976-01-01

    A new method of stereoscopic cerebral angiography was developed which employs 2X radiographic magnification. In order to obtain the same depth perception in the object as with conventional contact stereoscopic angiography, one can make the x-ray exposures at two focal spot positions which are separated by only 1 inch, whereas the contact technique requires a separation of 4 inches. The smaller distance is possible because, with 2X magnification, the transverse detail in the object is magnified by a factor of two, but the longitudinal detail, which is related to the stereo effect, is magnified by a factor of four, due to the longitudinal magnification effect. The small focal spot separation results in advantages such as improved stereoscopic image detail, better image quality, and low radiation exposure to the patient

  8. Application of longitudinal magnification effect to magnification stereoscopic angiography. A new method of cerebral angiography

    Energy Technology Data Exchange (ETDEWEB)

    Doi, K.; Rossmann, K.; Duda, E.E.

    1976-01-01

    A new method of stereoscopic cerebral angiography was developed which employs 2X radiographic magnification. In order to obtain the same depth perception in the object as with conventional contact stereoscopic angiography, one can make the x-ray exposures at two focal spot positions which are separated by only 1 inch, whereas the contact technique requires a separation of 4 inches. The smaller distance is possible because, with 2X magnification, the transverse detail in the object is magnified by a factor of two, but the longitudinal detail, which is related to the stereo effect, is magnified by a factor of four, due to the longitudinal magnification effect. The small focal spot separation results in advantages such as improved stereoscopic image detail, better image quality, and low radiation exposure to the patient.

  9. MR angiography of cerebral aneurysms

    International Nuclear Information System (INIS)

    Miki, Hitoshi; Tanada, Shuji; Sakaki, Saburo; Hamamoto, Ken; Sadamoto, Kazuhiko.

    1992-01-01

    Time-of-flight (TOF) MR angiography (MRA) and phase-contrast (PC) MRA are examined clinically for evaluating cerebral aneurysms. In the morphological diagnosis of cerebral aneurysms, three-dimensional (3D) MRA is superior to two-dimensional (2D) MRA because 3D MRA has a higher S/N ratio and a higher spatial resolution. However, it is difficult to decide which, 3D TOF MRA or 3D PC MRA, is superior, for both methods have many scan parameters. In our study, 3D PC MRA was performed using two methods; one had the same acquisition time as 3D TOF MRA, while the other had the same spatial resolution as 3D TOF MRA. The detectability of aneurysms by each MRA method was evaluated in comparison with 3D TOF MRA. In fifteen patients (6 males and 9 females), a total of 16 cerebral aneurysms (3 ruptured and 13 unruptured) were studied. The lesion sizes ranged from 2.5 to 18 mm. All the 16 lesions were examined by means of 3D TOF MRA, 3D PC MRA, and conventional angiography. MR imaging was performed with a 1.5 tesla MRI system (Signa). All of the 16 cerebral aneurysms were detected by 3D TOF MRA, while only 11 of them were detected by 3D PC MRA. When 3D PC MRA was performed with the same acquisition time as 3D TOF MRA, 3D PC MRA was superior in showing one of the 7 aneurysms. When 3D PC MRA was performed with same spatial resolution as 3D TOF MRA, 3D PC MRA was superior in showing two of the 10 aneurysms. 3D TOF MRA was superior to 3D PC MRA in the detection of cerebral aneurysms because of the long acquisition times and the different flow velocity, which induced different signal intensities between the aneurysms and parent arteries in 3D PC MRA. 3D PC MRA was superior to 3D TOF MRA in patients with large thrombotic aneurysms of the internal carotid artery. We consider that 3D TOF MRA should be the first choice for screening and following-up cerebral aneurysms. 3D PC MRA should then be performed for large cerebral aneurysms in addition to 3D TOF MRA. (author)

  10. First experience of combined cardiac PET/64-detector CT angiography with invasive angiographic validation

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Endozo, Raymondo; Menezes, Leon J.; Prvulovich, Elizabeth; Ell, Peter J.; Speechly-Dick, Marie-Elsya; McEwan, Jean; Pugliese, Francesca; Habib, Said B.

    2009-01-01

    Despite modern CT systems and expert evaluators, the diagnostic performance of coronary CT angiography is limited by overestimation of vessel stenosis which reduces the positive predictive value (PPV) of the test. The aim of this study was to evaluate the performance of combined cardiac PET/64-detector CT angiography. Included in this retrospective study were 33 consecutive patients (5 women, 28 men; mean age 61.6 years, range 47-87 years, mean BMI 27.3±5.2 kg/m 2 ) with clinically suspected flow-limiting coronary artery disease who underwent combined cardiac PET/64-detector CT angiography and invasive angiography. Combined PET/CT images were reported by an experienced dual-accredited radiologist/nuclear physician. An experienced cardiac CT radiologist re-read the CT images without PET. Stenotic disease was defined as >50% vessel narrowing. Invasive coronary angiography was used as a reference standard. Local ethics committee approval and patient consent were obtained. CT angiography (without PET data) was concordant with invasive angiography in 31/33 patients and at a patient level, the sensitivity in detecting significant coronary artery lesions was 100%, the specificity was 82%, the PPV was 92% and the negative predictive value (NPV) was 100%. Using combined PET/CT angiography the findings were concordant with invasive angiography in 32/33 patients and at a patient level, the sensitivity was 96%, the specificity was 100%, the PPV was 100% and the NPV was 91%. The use of integrated cardiac PET/64-detector CT angiography is feasible and appears to improve some aspects of the diagnostic performance of 64-detector coronary artery angiography in detecting coronary artery disease. (orig.)

  11. Multidetector CT angiography of renal vasculature: normal anatomy and variants

    International Nuclear Information System (INIS)

    Tuerkvatan, Aysel; Oezdemir, Mustafa; Cumhur, Turhan; Oelcer, Tuelay

    2009-01-01

    Knowledge of the variations in renal vascular anatomy is important before laparoscopic donor or partial nephrectomy and vascular reconstruction for renal artery stenosis or abdominal aortic aneurysm. Recently, multidetector computed tomographic (MDCT) angiography has become a principal imaging investigation for assessment of the renal vasculature and has challenged the role of conventional angiography. It is an excellent imaging technique because it is a fast and non-invasive tool that provides highly accurate and detailed evaluation of normal renal vascular anatomy and variants. The number, size and course of the renal arteries and veins are easily identified by MDCT angiography. The purpose of this pictorial essay is to illustrate MDCT angiographic appearance of normal anatomy and common variants of the renal vasculature. (orig.)

  12. Multidetector CT angiography of renal vasculature: normal anatomy and variants

    Energy Technology Data Exchange (ETDEWEB)

    Tuerkvatan, Aysel; Oezdemir, Mustafa; Cumhur, Turhan; Oelcer, Tuelay [Tuerkiye Yueksek ihtisas Hospital, Department of Radiology, Sihhiye, Ankara (Turkey)

    2009-01-15

    Knowledge of the variations in renal vascular anatomy is important before laparoscopic donor or partial nephrectomy and vascular reconstruction for renal artery stenosis or abdominal aortic aneurysm. Recently, multidetector computed tomographic (MDCT) angiography has become a principal imaging investigation for assessment of the renal vasculature and has challenged the role of conventional angiography. It is an excellent imaging technique because it is a fast and non-invasive tool that provides highly accurate and detailed evaluation of normal renal vascular anatomy and variants. The number, size and course of the renal arteries and veins are easily identified by MDCT angiography. The purpose of this pictorial essay is to illustrate MDCT angiographic appearance of normal anatomy and common variants of the renal vasculature. (orig.)

  13. Assessment of anemia during CT pulmonary angiography

    International Nuclear Information System (INIS)

    Jung, Caroline; Groth, Michael; Bley, Thorsten A.; Henes, Frank O.; Treszl, András; Adam, Gerhard; Bannas, Peter

    2012-01-01

    Objectives: Anemia is associated with increased mortality in patients with acute symptomatic pulmonary embolism (PE). The purpose of this study was to evaluate the feasibility of Hounsfield unit (HU) measurements on the single unenhanced trigger slice of pulmonary CT angiography scans for diagnosis of anemia. Material and Methods: 150 consecutive patients (median age 64 ± 16 years) with suspected PE underwent pulmonary CT angiography. Two radiologists, blinded to laboratory results, performed HU measurements in the single unenhanced trigger scan independently by region-based analysis (ROI). HU values from ascending and descending aorta and the calculated mean of both were correlated with serum hemoglobin levels. Inter- and intraobserver variability was determined for HU measurements, and ROC analysis was performed for diagnosis of anemia. Calculated linear models were used to assess formulas for estimation of hemoglobin levels from HU measurements. Results: HU measurements revealed high intra- and interrater reliability (ICC > 0.981 and ICC > 0.965, respectively). Calculated mean HU values showed a strong correlation with serum hemoglobin levels (r = 0.734), which allowed generation of different formulas for calculation of hemoglobin levels from HU measurements. ROC analyses confirmed a high sensitivity (80.4 for men; 91.3 for women) and specificity (84.0 for men; 84.9 for women) for diagnosing anemia. Conclusion: Diagnosis of anemia and quantification of hemoglobin levels upon a single unenhanced trigger scan of pulmonary CT angiography is feasible. We suggest disclosing the anemic state in the radiological report, independent of the presence of PE, since anemia carries increased risks of morbidity and mortality.

  14. Assessment of anemia during CT pulmonary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Caroline, E-mail: cjung@uke.de [Department of Diagnostic and Interventional Radiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany); Groth, Michael; Bley, Thorsten A.; Henes, Frank O. [Department of Diagnostic and Interventional Radiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany); Treszl, András [Department of Medical Biometry and Epidemiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany); Adam, Gerhard; Bannas, Peter [Department of Diagnostic and Interventional Radiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany)

    2012-12-15

    Objectives: Anemia is associated with increased mortality in patients with acute symptomatic pulmonary embolism (PE). The purpose of this study was to evaluate the feasibility of Hounsfield unit (HU) measurements on the single unenhanced trigger slice of pulmonary CT angiography scans for diagnosis of anemia. Material and Methods: 150 consecutive patients (median age 64 ± 16 years) with suspected PE underwent pulmonary CT angiography. Two radiologists, blinded to laboratory results, performed HU measurements in the single unenhanced trigger scan independently by region-based analysis (ROI). HU values from ascending and descending aorta and the calculated mean of both were correlated with serum hemoglobin levels. Inter- and intraobserver variability was determined for HU measurements, and ROC analysis was performed for diagnosis of anemia. Calculated linear models were used to assess formulas for estimation of hemoglobin levels from HU measurements. Results: HU measurements revealed high intra- and interrater reliability (ICC > 0.981 and ICC > 0.965, respectively). Calculated mean HU values showed a strong correlation with serum hemoglobin levels (r = 0.734), which allowed generation of different formulas for calculation of hemoglobin levels from HU measurements. ROC analyses confirmed a high sensitivity (80.4 for men; 91.3 for women) and specificity (84.0 for men; 84.9 for women) for diagnosing anemia. Conclusion: Diagnosis of anemia and quantification of hemoglobin levels upon a single unenhanced trigger scan of pulmonary CT angiography is feasible. We suggest disclosing the anemic state in the radiological report, independent of the presence of PE, since anemia carries increased risks of morbidity and mortality.

  15. Magnetic resonance angiography

    International Nuclear Information System (INIS)

    Kauczor, H.U.; Gamroth, A.H.; Schad, L.R.; Semmler, W.; Kaick, G. van; Tuengerthal, S.J.; Hausmann, R.

    1992-01-01

    MR angiography (MRA) proved to be promising combined to MR-Imaging (MRI) in the assessment of intrathoracic masses. Sequential FLASH 2D-angiograms were acquired in breathhold technique using the following parameters: TR=30 ms, TE=10 ms, FA=30deg. Section thickness was 5 mm with 1 mm overlap between sequential sections. Individual conditions of the examination were achieved by an automatised control procedure. Targeted MIP-postprocessing resulted in 3D-reconstructions illustrating vascular anatomy and avoiding superimposition. Presentation should be done by cine-mode for better spatial impression. This method was evaluated in a prospective study of 21 patients with malignant pulmonary and mediastinal masses in addition to spin-echo imaging. The diagnostic contribution concerning the relationship between the mass and the vasculature like displacement, stenosis, and poststenotic perfusion defect were assessed. (orig.) [de

  16. Digital subtraction angiography

    International Nuclear Information System (INIS)

    Neuwirth, J. Jr.; Bohutova, J.

    1987-01-01

    The quality of radiodiagnostic methods to a great extent depends on the quality of the resulting image. The basic technical principles are summed up of the different parts of digital subtraction angiography apparatus and of methods of improving the image. The instrument is based on a videochain consisting of an X-ray tube, an intensifier of the radiographic image, optical parts, a video camera, an analog-to-digital converter and a computer. The main advantage of the digitally processed image is the possibility of optimizing the image into a form which will contain the biggest amount of diagnostically valuable information. Described are the mathematical operations for improving the digital image: spatial filtration, pixel shift, time filtration, image integration, time interval differentation and matched filtering. (M.D.). 8 refs., 3 figs

  17. Comparison of digital subtraction angiography with gadolinium-enhanced magnetic resonance angiography in the diagnosis of renal artery stenosis

    International Nuclear Information System (INIS)

    Thornton, J.; O'Callaghan, J.; Varghese, J.C.; Lee, M.J.; Walshe, J.; O'Brien, E.

    1999-01-01

    Renal artery stenosis (RAS) is a treatable cause of hypertension and renal failure for which no ideal screening technique is currently available. We evaluated the use of dynamic gadolinium-enhanced magnetic resonance angiography (MRA) for the diagnosis of RAS. Sixty-two patients with secondary hypertension were enrolled in the study. All patients had conventional renal angiography and gadolinium enhanced MRA. The sequence used was a 3D FMP SPGR sequence with the following parameters (TR: 26 ms, TE: 6.9 ms, flip angle 40 , field of view 36 x 36 cm, matrix 246 x 256, 1 excitation). Gadolinium 0.3 mmol/kg was administered and 60 1.5-mm-thick partitions were obtained over a duration of 3.5 min. The MRA images were then compared with conventional digital subtraction angiography (DSA) images. Conventional DSA demonstrated 138 renal arteries, whereas gadolinium-enhanced MRA demonstrated 129 (93 %). Twenty-one renal artery stenoses and four occluded arteries were seen at conventional DSA. Gadolinium-enhanced MRA had a sensitivity of 88 %, specificity of 98 %, accuracy of 96 %, positive predictive value of 92 % and negative predictive value of 97 % when compared with conventional DSA. Gadolinium-enhanced MRA is an accurate technique for identifying patients with RAS. It is less sensitive in picking up accessory renal arteries. (orig.)

  18. DIAGNOSTIC ACCURACY OF MAGNETIC RESONANCE ANGIOGRAPHY FOR UNRUPTURED CEREBRAL ANEURYSMS IN CORRELATION WITH DIGITAL SUBTRACTION ANGIOGRAPHY

    Directory of Open Access Journals (Sweden)

    Aleksandra Aracki-Trenkić

    2015-09-01

    Full Text Available Intracranial aneurysm is a focal, abnormal dilation of an artery of the brain. Magnetic resonance angiography (MRA is a non-invasive technique for vascular imaging and is thus widely used for screening for intracranial vascular lesions. The aim of the study was to show the diagnostic accuracy of 3D Time-of-Flight (3D TOF MRA in the detection of unruptured cerebral aneurysms with the use of digital subtraction angiography (DSA as the gold standard. A total of 2.612 consecutive patients underwent 3DTOF MRA. It showed unruptured aneurysms in 94 (3.6% patients. They included 68 women and 26 men ranging in age from 29 to 76 years (mean, 52.5 years. Twenty-six of them, 20 women and 6 men, underwent DSA. The Mann-Whitney U test was used for the correlation of size. Fisher’s test was used for the correlation of location. The statistical level of significance was set at p0.05 of aneurysms between TOF MRA and DSA. MRA is an accurate and non-invasive method for diagnosis of unruptured intracranial aneurysms. The results of study show the compatibility of MRA findings, the location and the size of an aneurysm in comparison with the “gold standard” – cerebral DSA.

  19. Role of myocardial perfusion scintigraphy post invasive coronary angiography in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Harisankar, C.N.B.; Mittal, Bhagwant Rai; Kamaleshwaran, K.K.; Bhattacharya, Anish; Singh, Baljinder; Mahajan, Rajiv

    2010-01-01

    The presence of severe hypokinesia or akinesia and near complete stenotic lesions on coronary angiography, in a patient with acute myocardial infarction raises a question of viability in the involved territory and its response to revascularization. The decision of revascularization can be effectively taken after myocardial perfusion scintigraphy (MPS). Aim: To evaluate the role of MPS in patients with acute or recent myocardial infarction after invasive coronary angiography. Materials and Methods: Thirty-five patients (27 Males, 8 Females; Mean age 54 years) with acute myocardial infarction, who underwent invasive angiography, were included prospectively. Invasive angiography was attempted during the episode of acute chest pain in 20 patients. Fifteen patients underwent angiography without MPS because of non-availability of MPS at the time of initial presentation in the referring hospital. Revascularization was deferred because of complete/near complete block of artery with hypokinesia/akinesia of the distal LV segments in 32/35 patients and 50 to 70% block in 3/35. These patients were subjected to MPS. Results: Twenty patients underwent stress MPS and 15 underwent nitrate-augmented rest re-distribution study (RR study). Imaging was performed using the hybrid SPECT/CT system. The average defect size of the perfusion defect was 34% (5 - 57% range). Sixteen patients (46%) had fixed perfusion defects. Reversible ischemia was present in 19 (54%). Ten patients had a 10% of the LV myocardium, and underwent the invasive revascularization procedure. Conclusion: MPS is invaluable in patients who have total/near total occlusion of the coronary artery and distal segment hypokinesia or akinesia on invasive angiography. One in four patients, deemed to have non-viable myocardium, underwent an invasive revascularization after undergoing MPS. (author)

  20. Megarectumsigma underwent surgery for chronic faecal impact action

    International Nuclear Information System (INIS)

    Canessa, C.; Gomez del Valle, M.; Caraballo, M.

    2002-01-01

    Seven patients with megarectumsigma underwent surgery for chronic faecal impaction,reviewing clinical diagnosis, aetiology and medical and surgical management.It is suggested medical management of chronic faecal impaction trying to achieve elective surgery.The curative surgery should include the resection of all pathologic bowel, but in Duhamel procedure and its modifications distal rectal tran section should be at the peritoneal reflection.Habr-Gama modification has shown to be technically easier and it has been communicated good functional results.Local unfavourable conditions may be resolve by staged surgery,which allows outline definitive bowel reconstruction after functional assessment

  1. Optimization of Ecg Gating in Quantitative Femoral Angiography

    International Nuclear Information System (INIS)

    Nilsson, S.; Berglund, I.; Erikson, U.; Johansson, J.; Walldius, G.

    2003-01-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase

  2. Optimization of Ecg Gating in Quantitative Femoral Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, S.; Berglund, I.; Erikson, U. [Univ. Hospital, Uppsala (Sweden). Dept. of Oncology, Radiology and Clinical Immunology; Johansson, J.; Walldius, G. [Karolinska Hospital, Stockholm (Sweden). King Gustav V Research Inst.

    2003-09-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase.

  3. New method of digital angiography

    International Nuclear Information System (INIS)

    Hashiya, Junichi; Korenaga, Takeo; Sakurai, Kenji; Sakai, Fumikazu; Kato, Hisatoyo; Takano, Masao.

    1982-01-01

    New experience of digital angiography using Fuji Intelligent Diagnostic X-ray System was reported. The system utilizes newly developed high sensitivity imaging plate in conjunction with computerized image processor instead of image intensifier-TV series, thus drastically improving image quality. Initial clinical trial was made in 46 cases including intravenous digital subtraction angiography and transcatheter digital arteriography. The advantages of this method were summerized as: 1. better resolution, 2. wider field size, 3. more sophisticated image manipulation program. (author)

  4. Mono-energy coronary angiography with a compact light source

    Science.gov (United States)

    Eggl, Elena; Mechlem, Korbinian; Braig, Eva; Kulpe, Stephanie; Dierolf, Martin; Günther, Benedikt; Achterhold, Klaus; Herzen, Julia; Gleich, Bernhard; Rummeny, Ernst; Noël, Peter B.; Pfeiffer, Franz; Muenzel, Daniela

    2017-03-01

    While conventional x-ray tube sources reliably provide high-power x-ray beams for everyday clinical practice, the broad spectra that are inherent to these sources compromise the diagnostic image quality. For a monochromatic x-ray source on the other hand, the x-ray energy can be adjusted to optimal conditions with respect to contrast and dose. However, large-scale synchrotron sources impose high spatial and financial demands, making them unsuitable for clinical practice. During the last decades, research has brought up compact synchrotron sources based on inverse Compton scattering, which deliver a highly brilliant, quasi-monochromatic, tunable x-ray beam, yet fitting into a standard laboratory. One application that could benefit from the invention of these sources in clinical practice is coronary angiography. Being an important and frequently applied diagnostic tool, a high number of complications in angiography, such as renal failure, allergic reaction, or hyperthyroidism, are caused by the large amount of iodine-based contrast agent that is required for achieving sufficient image contrast. Here we demonstrate monochromatic angiography of a porcine heart acquired at the MuCLS, the first compact synchrotron source. By means of a simulation, the CNR in a coronary angiography image achieved with the quasi-mono-energetic MuCLS spectrum is analyzed and compared to a conventional x-ray-tube spectrum. The results imply that the improved CNR achieved with a quasi-monochromatic spectrum can allow for a significant reduction of iodine contrast material.

  5. Comparison of fluoro and cine coronary angiography: balancing acceptable outcomes with a reduction in radiation dose.

    Science.gov (United States)

    Olcay, Ayhan; Guler, Ekrem; Karaca, Ibrahim Oguz; Omaygenc, Mehmet Onur; Kizilirmak, Filiz; Olgun, Erkam; Yenipinar, Esra; Cakmak, Huseyin Altug; Duman, Dursun

    2015-04-01

    Use of last fluoro hold (LFH) mode in fluoroscopy, which enables the last live image to be saved and displayed, could reduce radiation during percutaneous coronary intervention when compared with cine mode. No previous study compared coronary angiography radiation doses and image quality between LFH and conventional cine mode techniques. We compared cumulative dose-area product (DAP), cumulative air kerma, fluoroscopy time, contrast use, interobserver variability of visual assessment between LFH angiography, and conventional cine angiography techniques. Forty-six patients were prospectively enrolled into the LFH group and 82 patients into the cine angiography group according to operator decision. Mean cumulative DAP was higher in the cine group vs the LFH group (50058.98 ± 53542.71 mGy•cm² vs 11349.2 ± 8796.46 mGy•cm²; Pcine group vs the LFH group (3.87 ± 5.08 minutes vs 1.66 ± 1.51 minutes; Pcine group vs the LFH group (112.07 ± 43.79 cc vs 88.15 ± 23.84 cc; Pcine and LFH angiography groups (0.66680 ± 0.19309 vs 0.54193 ± 0.31046; P=.20). Radiation doses, contrast use, and fluoroscopy times are lower in fluoroscopic LFH angiography vs cine angiography. Interclass variability of visual stenosis estimation between three operators was not different between cine and LFH groups. Fluoroscopic LFH images conventionally have inferior diagnostic quality when compared with cine coronary angiography, but with new angiographic systems with improved LFH image quality, these images may be adequate for diagnostic coronary angiography.

  6. Advanced virtual monoenergetic images: improving the contrast of dual-energy CT pulmonary angiography

    International Nuclear Information System (INIS)

    Meier, A.; Wurnig, M.; Desbiolles, L.; Leschka, S.; Frauenfelder, T.; Alkadhi, H.

    2015-01-01

    Aim: To investigate the value of advanced virtual monoenergetic image reconstruction (mono-plus) from dual-energy computed tomography (CT) for improving the contrast of CT pulmonary angiography (CTPA). Materials and methods: Forty consecutive patients (25 women, mean 62.5 years, range 28–87 years) underwent 192-section dual-source CTPA with dual-energy CT (90/150 SnkVp) after the administration of 60 ml contrast media (300 mg iodine/ml). Conventional virtual monochromatic images at 60 keV and 17 mono-plus image datasets from 40–190 keV (in 10 keV steps) were reconstructed. Subjective image quality (artefacts, subjective noise) was rated. Attenuation was measured in the pulmonary trunk and in the right lower lobe pulmonary artery; noise was measured in the periscapular musculature. The signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated for each patient and dataset. Comparisons between monochromatic images and mono-plus images were performed by repeated measures analysis of variance (ANOVA) with post-hoc Bonferroni correction. Results: Interreader agreement was good to excellent for subjective image quality (ICC: 0.616–0.889). As compared to conventional 60 keV images, artefacts occurred less (p=0.001) and subjective noise was rated lower (p<0.001) in mono-plus 40 keV images. Noise was lower (p<0.001), and the SNR and CNR in the pulmonary trunk and right lower lobe pulmonary artery were higher (both, p<0.001) in mono-plus 40 keV images compared to conventional monoenergetic 60 keV images. Transient interruption of contrast (TIC) was found in 14/40 (35%) of patients, with subjective contrast being similar 8/40 (20%) or higher 32/40 (80%) in mono-plus 40 keV as compared to conventional monoenergetic 60 keV images. Conclusions: Compared to conventional virtual monoenergetic imaging, mono-plus images at 40 keV improve the contrast of dual-energy CTPA. - Highlights: • Advanced monoenergetic image reconstruction from dual-energy CT

  7. Dual energy CT intracranial angiography: image quality, radiation dose and initial application results

    International Nuclear Information System (INIS)

    Chai Xue; Zhang Longjiang; Lu Guangming; Zhou Changsheng

    2009-01-01

    Objective: To assess the clinical value of dual-energy intracranial CT angiography (CTA). Methods: Forty-one patients suspected of intracranial vascular diseases underwent dual-energy intracranial CT angiography, and 41 patients who underwent conventional subtraction CT were enrolled as the control group. Image quality of intracranial and skull base vessels and radiation dose between dual-energy CTA and conventional subtraction CTA were compared using two independent sample nonparametric test and independent-samples t test, respectively. Prevalence and size of lesions detected by dual-energy CTA and digital subtraction CTA were compared using paired-samples t test and Spearman correlative analysis. Results: The percentage of image quality scored 5 was 70.7% (29/41) for dual-energy CTA and 75.6% (31/41) for conventional subtraction CTA. There was no significant difference between the two groups (Z= -0.455, P=0.650). Image quality of vessels at the skull base in conventional subtraction CTA was superior to that in dual-energy CTA, especially for the petrosal and syphon segment (Z=-4.087, P=0.000). Radiation exposure of dual energy CTA and conventional CTA were (396.54±17.43) and (1090.95±114.29) mGy·cm respectively. Radiation exposure was decreased by 64% (t=-38.52, P=0.000) by dual energy CTA compared with conventional subtraction CTA. Out of the 41 patients, 19 patients were diagnosed as intracranial aneurysm, 2 patients as arteriovenous malformation (AVM), 3 patients with Moya-moya's disease, and the remaining 17 patients with negative results. Nine patients with intracranial aneurysm, 2 patients with AVM, 3 patients with Moya-moya's disease, and 2 patients with negative findings underwent DSA or operation, with concordant findings from both techniques. Diameter of aneurysm neck, long axis and minor axis by dual-energy CTA was (2.90±1.61), (5.23±1.68) and (3.83±1.69) mm, respectively; Diameter of aneurysm neck, long axis and minor axis by DSA was (2.95±1

  8. Usefulness of three-dimensional contrast-enhanced MR angiography in the evaluation of pelvic and lower extremity arteries

    International Nuclear Information System (INIS)

    Kim, Young Kon; Han, Young Min; Lee, Jeong Min

    2002-01-01

    To evaluate the feasibility and clinical usefulness of three-dimensional contrast-enhanced MR angiography (3D-CE-MRA) as a screening test in the evaluation of pelvic and lower extremity arterial diseases. Forty-four patients who underwent 3D-CE-MRA were included in this study. Coronal 3-dimensional gradient-echo, pre-and post contrast image were acquired with a dedicated peripheral vascular coil and moving-bed technique on a 1.5T MR system. Timing of start of data acquisition was determined by MR fluoroscopy technique, and 0.2 mmol/kg Gd-DTPA was injected into an antecubital vein, at a rate of 1cc/sec with an autoinjector. For quantitative analysis, signal to noise ratio (SNR) and artery to soft tissue contrast to noise ratio (CNR) of lower extremities arterial system including lower abdominal aorta were calculated. For qualitative analysis, arterial systems were divided into six segments, and were evaluated in terms of conspicuity of arterial systems and the degree of venous enhancement by three- and four-point scale respectively. In eight patients who underwent both MR angiography and conventional angiography as standard reference. Imaging analysis was done by means of consensus between two experienced radiologists. The mean time for the examination was about 15 min (± 5 min). The mean SNR of arterial system was 26.5±11.6, and mean artery to soft tissue contrast to noise ratio (CNR) was 24.6±11.2. Among the total 525 arterial segments 498 arterial segments (94.5%) could be demonstrated with good delineation of entire arterial tree. Good arterial imaging without or with minimal venous enhancement were demonstrated in 98.5% (260/264) in above knee and 89% (211/261) in below knee (p<0.01). Ten of 525 segments (1.9%) demonstrated severe venous overlapping and it mostly occurred in the calf region. In comparison with DSA, the sensitivity and the specificity for MR angiography for the detection of occlusions were 96% and 98.8%, respectively, and for the detection of

  9. ALGORITHM FOR MANAGEMENT OF HYPERTENSIVE PATIENTS UNDERWENT UROLOGY INTERVENTIONS

    Directory of Open Access Journals (Sweden)

    S. S. Davydova

    2013-01-01

    Full Text Available Aim. To study the efficacy of cardiovascular non-invasive complex assessment and pre-operative preparation in hypertensive patients needed in surgical treatment of urology dis- eases.Material and methods. Males (n=883, aged 40 to 80 years were included into the study. The main group consisted of patients that underwent laparotomic nephrectomy (LTN group; n=96 and patients who underwent laparoscopic nephrectomy (LSN group; n=53. Dynamics of ambulatory blood pressure monitoring (ABPM data was analyzed in these groups in the immediate postoperative period. The efficacy of a package of non-invasive methods for cardiovascular system assessment was studied. ABPM was performed after nephrectomy (2-nd and 10-th days after surgery in patients with complaints of vertigo episodes or intense general weakness to correct treatment.Results. In LTN group hypotension episodes or blood pressure (BP elevations were observed in 20 (20.8% and 22 (22.9% patients, respectively, on the 2-nd day after the operation. These complications required antihypertensive treatment correction. Patients with hypotension episodes were significantly older than patients with BP elevation and had significantly lower levels of 24-hour systolic BP, night diastolic BP and minimal night systolic BP. Re-adjustment of antihypertensive treatment on the 10-th postoperative day was required to 2 (10% patients with hypotension episodes and to 1 (4.5% patient with BP elevation. Correction of antihypertensive therapy was required to all patients in LSN group on the day 2, and to 32 (60.4% patients on the 10-th day after the operation. Reduction in the incidence of complications (from 1.2% in 2009 to 0.3% in 2011, p<0.001 was observed during the application of cardiovascular non-invasive complex assessment and preoperative preparation in hypertensive patients.Conclusion. The elaborated management algorithm for patients with concomitant hypertension is recommended to reduce the cardiovascular

  10. ALGORITHM FOR MANAGEMENT OF HYPERTENSIVE PATIENTS UNDERWENT UROLOGY INTERVENTIONS

    Directory of Open Access Journals (Sweden)

    S. S. Davydova

    2015-09-01

    Full Text Available Aim. To study the efficacy of cardiovascular non-invasive complex assessment and pre-operative preparation in hypertensive patients needed in surgical treatment of urology dis- eases.Material and methods. Males (n=883, aged 40 to 80 years were included into the study. The main group consisted of patients that underwent laparotomic nephrectomy (LTN group; n=96 and patients who underwent laparoscopic nephrectomy (LSN group; n=53. Dynamics of ambulatory blood pressure monitoring (ABPM data was analyzed in these groups in the immediate postoperative period. The efficacy of a package of non-invasive methods for cardiovascular system assessment was studied. ABPM was performed after nephrectomy (2-nd and 10-th days after surgery in patients with complaints of vertigo episodes or intense general weakness to correct treatment.Results. In LTN group hypotension episodes or blood pressure (BP elevations were observed in 20 (20.8% and 22 (22.9% patients, respectively, on the 2-nd day after the operation. These complications required antihypertensive treatment correction. Patients with hypotension episodes were significantly older than patients with BP elevation and had significantly lower levels of 24-hour systolic BP, night diastolic BP and minimal night systolic BP. Re-adjustment of antihypertensive treatment on the 10-th postoperative day was required to 2 (10% patients with hypotension episodes and to 1 (4.5% patient with BP elevation. Correction of antihypertensive therapy was required to all patients in LSN group on the day 2, and to 32 (60.4% patients on the 10-th day after the operation. Reduction in the incidence of complications (from 1.2% in 2009 to 0.3% in 2011, p<0.001 was observed during the application of cardiovascular non-invasive complex assessment and preoperative preparation in hypertensive patients.Conclusion. The elaborated management algorithm for patients with concomitant hypertension is recommended to reduce the cardiovascular

  11. Descriptive retrospective analysis of the diagnostic yield and morbidity of four vessel catheter-directed cerebral angiography and multidetector computed tomographic angiography (MDCTA) performed at Inkosi Albert Luthuli Central Hospital (IALCH)

    International Nuclear Information System (INIS)

    Sabri, A.; Robbs, J.V.; Maharajh, J.; Sikwila, T.C.

    2011-01-01

    Imaging studies are indispensable in order to determine the source, location and pattern of intra and extra-axial brain haemorrhages. In our study of 277 patients carried out over an 18 month period, the most common reason of referral was subarachnoid haemorrhage followed by trauma. Aneurysms were the most common diagnosis (36%) with anterior and posterior communicating arteries being the most common locations. Fifty percent (50%) of patients investigated had a normal study. Our findings show that the yield from MDCTA and conventional angiography was relatively comparable, however, conventional angiography was superior in detection of aneurysms; hence, in cases were the MDCTA result was found to be normal despite a high index of suspicion for a subarachnoid haemorrhage, a follow-up MDCTA study or conventional angiography is useful. Moreover, conventional angiography was superior in detection of multiple aneurysms.

  12. Descriptive retrospective analysis of the diagnostic yield and morbidity of four vessel catheter-directed cerebral angiography and multidetector computed tomographic angiography (MDCTA) performed at Inkosi Albert Luthuli Central Hospital (IALCH)

    Energy Technology Data Exchange (ETDEWEB)

    Sabri, A., E-mail: sabri.ali@gmail.com [University of Kwazulu Natal, College of Health Sciences, Nelson R Mandela School of Medicine, School of Surgical Disciplines, Department of Radiology, Private Bag 7, Congella 4013, Durban (South Africa); Robbs, J.V., E-mail: jvrobbs@mweb.co.za [University of Kwazulu Natal, College of Health Sciences, Nelson R Mandela School of Medicine, School of Surgical Disciplines, Department of Surgery, Durban (South Africa); Maharajh, J., E-mail: Jaynund.Maharajh@kznhealth.gov.za [University of Kwazulu Natal, College of Health Sciences, Nelson R Mandela School of Medicine, School of Surgical Disciplines, Department of Radiology, Private Bag 7, Congella 4013, Durban (South Africa); Sikwila, T.C., E-mail: tcsikwila@yahoo.co.uk [University of Kwazulu Natal, College of Health Sciences, Nelson R Mandela School of Medicine, School of Surgical Disciplines, Department of Radiology, Private Bag 7, Congella 4013, Durban (South Africa)

    2011-11-15

    Imaging studies are indispensable in order to determine the source, location and pattern of intra and extra-axial brain haemorrhages. In our study of 277 patients carried out over an 18 month period, the most common reason of referral was subarachnoid haemorrhage followed by trauma. Aneurysms were the most common diagnosis (36%) with anterior and posterior communicating arteries being the most common locations. Fifty percent (50%) of patients investigated had a normal study. Our findings show that the yield from MDCTA and conventional angiography was relatively comparable, however, conventional angiography was superior in detection of aneurysms; hence, in cases were the MDCTA result was found to be normal despite a high index of suspicion for a subarachnoid haemorrhage, a follow-up MDCTA study or conventional angiography is useful. Moreover, conventional angiography was superior in detection of multiple aneurysms.

  13. Spontaneous vertebral dissection: Clinical, conventional angiographic, CT, and MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Provenzale, J.M.; Morgenlander, J.C. [Duke Univ. Medical Center, Durham, NC (United States); Gress, D. [Univ. of California, San Francisco, CA (United States)

    1996-03-01

    The purpose of this study was to determine if typical clinical and neuroradiologic patterns exist in patients with spontaneous vertebral artery (VA) dissection. The medical records and neuroradiologic examinations of 14 patients with spontaneous VA dissection were reviewed. The medical records were examined to exclude patients with a history of trauma and to record evidence of a nontratimatic precipitating event ({open_quotes}trivial trauma{close_quotes}) and presence of possible risk factors such as hypertension. All patients under-went conventional angiography, 13 either CT or MRI (II both CT and MRI), and 3 MRA. Conventional arteriograrris were evaluated for dissection site, evidence of fibromuscular dysplasia, luminal stenosis or occlusion, and pseudoaneurysm formation, CT examinations for the presence of infarction or subarachnoid hemorrhage, MR examinations for the presence of infarction or arterial signal abnormality, and MR angiograms for abnormality of the arterial signal column. Seven patients had precipitating events within 24 h of onset of symptoms that may have been causative of dissection and five had hypertension. At catheter angiography, two patients had dissections in two arteries (both VAs in one patient, VA and internal carotid artery in one patient), giving a total of 15 VAs with dissection. Dissection sites included V1 in four patients, V2 in one patient, V3 in three patients, V4 in six patients, and both V3 and V4 in one patient. Luminal stenosis was present in 13 VAs, occlusion in 2, pseudoaneurysm in 1, and evidence of fibromuscular dysplasia in 1. Posterior circulation infarcts were found on CT or MR in five patients. Subarachnoid hemorrhage was found on CT in two patients and by lumbar puncture alone in two patients. Abnormal periarterial signal on MRI was seen in three patients. MRA demonstrated absent VA signal in one patient, pseudoaneurysm in one, and a false-negative examination in one.

  14. MR angiography in diagnosing and following up the treatment result: arteria lusoria

    International Nuclear Information System (INIS)

    Vogl, T.J.; Juergens, M.; Harms, J.; Pegios, W.; Zimmermann, A.; Hetzer, R.; Felix, R.

    1994-01-01

    Diagnostic and therapeutic procedures are presented in a 29-year-old female patient who suffered from severe dysphagia and rapid loss in weight. In the conventional X-ray examination and barium swallow an aberrant right subclavian artery was suspected. MR imaging (MRI) and MR angiography (MRA) were done to plan the surgical correction. Post-operative MRA documented exactly the complex topography after surgical correction and the flow pattern in the implanted Gore-Tex stretch graft prosthesis. Non-invasive MR angiography renders possible the concrete planning of complex corrections of thoracic vessels replacing invasive catheter angiography. (orig.) [de

  15. The accuracy and utility of contrast-enhanced MR angiography for localization of spinal dural arteriovenous fistulas: the Toronto experience

    Energy Technology Data Exchange (ETDEWEB)

    Lindenholz, Arjen [University Medical Center Groningen, Department of Neurosurgery AB71, PO Box 30001, Groningen (Netherlands); Toronto Western Hospital, Department of Medical Imaging, Division of Neuroradiology, Toronto, ON (Canada); TerBrugge, Karel G.; Farb, Richard I. [Toronto Western Hospital, Department of Medical Imaging, Division of Neuroradiology, Toronto, ON (Canada); Dijk, J.M.C. van [University Medical Center Groningen, Department of Neurosurgery AB71, PO Box 30001, Groningen (Netherlands)

    2014-11-15

    The purpose of this study was to determine the accuracy and utility of contrast-enhanced MR angiography (CE-MRA) in spinal dural arteriovenous fistulas (SDAVF). A retrospective analysis from 1999-2012 identified 70 patients clinically suspected of harboring a SDAVF. Each patient underwent consecutive conventional MR-imaging, CE-MRA, and digital subtraction angiography (DSA). The presence or absence of serpentine flow voids, T2-weighted hyperintensity, and cord enhancement were evaluated, as well as location of the fistula as predicted by CE-MRA. DSA was used as the reference standard. Of the 70 cases, 53 were determined to be a SDAVF, 10 cases were shown to be other forms of vascular malformation, and 7 were DSA-negative. On MRI, all reported cases of SDAVF showed serpentine flow voids (100 %). T2-weighted hyperintensity was seen in 48 of 50 cases (96 %), extending to the conus in 41 of 48 cases (85 %). Cord enhancement was seen in 38 of 41 cases (93 %). CE-MRA correctly localized the SDAVF in 43 of the 53 cases (81 %). CE-MRA is a useful non-invasive examination for the detection and localization of SDAVF. CE-MRA facilitates but does not replace DSA as confirmation of location, fistula type, and arterial detail, which are required before treatment. (orig.)

  16. High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience

    International Nuclear Information System (INIS)

    Beeres, Martin; Schell, Boris; Mastragelopoulos, Aristidis; Kerl, Josef Matthias; Gruber-Rouh, Tatjana; Lee, Clara; Siebenhandl, Petra; Bodelle, Boris; Zangos, Stephan; Vogl, Thomas J.; Jacobi, Volkmar; Bauer, Ralf W.; Herrmann, Eva

    2012-01-01

    To investigate the feasibility, image quality and radiation dose for high-pitch dual-source CT angiography (CTA) of the whole aorta without ECG synchronisation. Each group of 40 patients underwent CTA either on a 16-slice (group 1) or dual-source CT device with conventional single-source (group 2) or high-pitch mode with a pitch of 3.0 (group 3). The presence of motion or stair-step artefacts of the thoracic aorta was independently assessed by two readers. Subjective and objective scoring of motion and artefacts were significantly reduced in the high-pitch examination protocol (p < 0.05). The imaging length was not significantly different, but the imaging time was significantly (p < 0.001) shorter in the high-pitch group (12.2 vs. 7.4 vs. 1.7 s for groups 1, 2 and 3). The ascending aorta and the coronary ostia were reliably evaluable in all patients of group 3 without motion artefacts as well. High-pitch dual-source CT angiography of the whole aorta is feasible in unselected patients. As a significant advantage over regular pitch protocols, motion-free imaging of the aorta is possible without ECG synchronisation. Thus, this CT mode bears potential to become a standard CT protocol before trans-catheter aortic valve implantation (TAVI). (orig.)

  17. Neurologic complications of cerebral angiography in childhood moyamoya syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, R.L.; Chavali, R.V.; Robson, C.D.; Barnes, P.D.; Burrows, P.E. [Department of Radiology, Children`s Hospital Medical Center, Boston, MA (United States); Eldredge, E.A. [Department of Anesthesia, Children`s Hospital Medical Center and Harvard Medical School, Boston, MA (United States); Scott, R.M. [Department of Neurosurgery, Children`s Hospital Medical Center and Harvard Medical School, Boston, MA (United States)

    1998-11-01

    Purpose. To determine the incidence of neurologic complications of cerebral angiography in children with moyamoya syndrome (MMS) as compared to children without MMS. Materials and methods. One-hundred-ninety consecutive cerebral angiograms obtained in 152 children were evaluated. Sixty of these angiograms were obtained in 40 children with MMS. Patients underwent neurologic evaluation prior to and after the procedure. For this study, a neurologic complication was defined as any new focal neurologic deficit or alteration in mental status occurring during the procedure or within the ensuing 24 hours. Results. There were 2 neurologic complications within 24 hours of angiography, one in the MMS group and one in the non-MMS group. One patient with MMS became mute following angiography. The symptom resolved within 12 hours. One patient without MMS being examined postoperatively for residual arteriovenous malformation developed intracranial hemorrhage requiring reexploration 12 hours after the angiogram. Using a two-tail Fisher`s exact test, there was no significant statistical difference in the ischemic (P = 0.3) or hemorrhagic (P = 1.0) complication rates between the group of patients with MMS and the non-MMS groups. Conclusion. The risk of a neurologic complication from cerebral angiography in children with MMS is low and not statistically different from the risk in children with other cerebrovascular disorders. (orig.) With 8 tabs., 37 refs.

  18. Neurologic complications of cerebral angiography in childhood moyamoya syndrome

    International Nuclear Information System (INIS)

    Robertson, R.L.; Chavali, R.V.; Robson, C.D.; Barnes, P.D.; Burrows, P.E.; Eldredge, E.A.; Scott, R.M.

    1998-01-01

    Purpose. To determine the incidence of neurologic complications of cerebral angiography in children with moyamoya syndrome (MMS) as compared to children without MMS. Materials and methods. One-hundred-ninety consecutive cerebral angiograms obtained in 152 children were evaluated. Sixty of these angiograms were obtained in 40 children with MMS. Patients underwent neurologic evaluation prior to and after the procedure. For this study, a neurologic complication was defined as any new focal neurologic deficit or alteration in mental status occurring during the procedure or within the ensuing 24 hours. Results. There were 2 neurologic complications within 24 hours of angiography, one in the MMS group and one in the non-MMS group. One patient with MMS became mute following angiography. The symptom resolved within 12 hours. One patient without MMS being examined postoperatively for residual arteriovenous malformation developed intracranial hemorrhage requiring reexploration 12 hours after the angiogram. Using a two-tail Fisher's exact test, there was no significant statistical difference in the ischemic (P = 0.3) or hemorrhagic (P = 1.0) complication rates between the group of patients with MMS and the non-MMS groups. Conclusion. The risk of a neurologic complication from cerebral angiography in children with MMS is low and not statistically different from the risk in children with other cerebrovascular disorders. (orig.)

  19. Evaluation of angiography performed by radiographers and nurses

    Energy Technology Data Exchange (ETDEWEB)

    Chalmers, N.; Conway, B.; Andrew, H.; Parkinson, A.; Butterfield, J.S.; Fawcitt, R. A

    2002-04-01

    AIM: To evaluate out-patient angiography performed by nurses and radiographers. MATERIALS AND METHODS: A protocol for out-patient angiography performed by nurses and radiographers was drawn up and approved by the Trust's Risk Management Committee. Following training, two experienced radiographers and one nurse undertook elective peripheral or renal angiography according to the protocol on 187 patients. Angiograms were performed using a 3F catheter introduced into the abdominal aorta from a femoral approach. Patients were discharged after 2 hours and contacted by telephone the following morning. RESULTS: No patient refused consent for the procedure. One hundred and seventy-two patients underwent successful catheterization without assistance from a radiologist. Radiologist assistance was required with femoral puncture or catheter/guidewire manipulation in 15 cases (8%). Images were considered diagnostic by the reporting radiologist in all but one case. This patient was recalled for further aortogram and pressure measurements. There was a single puncture site complication due to transient stenosis of the common femoral artery at the puncture site. This is thought to have been the result of subintimal injection of local anaesthetic, and it resolved spontaneously over 30 minutes. There were no delayed complications. CONCLUSION: Experienced nurses and radiographers can rapidly acquire the skills to perform diagnostic angiography safely and efficiently. Chalmers, N. et al. (2002)

  20. Evaluation of angiography performed by radiographers and nurses

    International Nuclear Information System (INIS)

    Chalmers, N.; Conway, B.; Andrew, H.; Parkinson, A.; Butterfield, J.S.; Fawcitt, R. A.

    2002-01-01

    AIM: To evaluate out-patient angiography performed by nurses and radiographers. MATERIALS AND METHODS: A protocol for out-patient angiography performed by nurses and radiographers was drawn up and approved by the Trust's Risk Management Committee. Following training, two experienced radiographers and one nurse undertook elective peripheral or renal angiography according to the protocol on 187 patients. Angiograms were performed using a 3F catheter introduced into the abdominal aorta from a femoral approach. Patients were discharged after 2 hours and contacted by telephone the following morning. RESULTS: No patient refused consent for the procedure. One hundred and seventy-two patients underwent successful catheterization without assistance from a radiologist. Radiologist assistance was required with femoral puncture or catheter/guidewire manipulation in 15 cases (8%). Images were considered diagnostic by the reporting radiologist in all but one case. This patient was recalled for further aortogram and pressure measurements. There was a single puncture site complication due to transient stenosis of the common femoral artery at the puncture site. This is thought to have been the result of subintimal injection of local anaesthetic, and it resolved spontaneously over 30 minutes. There were no delayed complications. CONCLUSION: Experienced nurses and radiographers can rapidly acquire the skills to perform diagnostic angiography safely and efficiently. Chalmers, N. et al. (2002)

  1. Wedge and subselective pulmonary angiography in pulmonary hypertension secondary to venous obstruction

    International Nuclear Information System (INIS)

    Bowen, J.S.; Bookstein, J.J.; Johnson, A.D.; Peterson, K.L.; Moser, K.M.

    1985-01-01

    Pulmonary wedge or subselective angiography provided key diagnostic information in two cases of pulmonary hypertension secondary to pulmonary venous obstruction. Whereas conventional pulmonary angiograms and ventilation-perfusion lung scans were interpreted as showing embolism, plain radiographs demonstrated Kerley B lines, suggesting venous obstruction. Subselective or wedge angiography of nonopacified arteries verified their anatomical patency and also revealed venous stenoses, collaterals, and atrophy indicative of obstruction

  2. Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Koike, Yuya, E-mail: r06118@hotmail.co.jp; Nishimura, Jun-ichi, E-mail: jun-ichi-n@nifty.com; Hase, Soichiro, E-mail: haseman@hotmail.co.jp; Yamasaki, Motoshige, E-mail: genyamasaki@gmail.com [Kawasaki Saiwai Hospital, Department of Interventional Radiology (Japan)

    2015-04-15

    PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasation of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.

  3. Digital subtraction angiography with an Isocon camera system: clinical applications

    International Nuclear Information System (INIS)

    Barbaric, Z.L.; Gomes, A.S.; Deckard, M.E.; Nelson, R.S.; Moler, C.L.

    1984-01-01

    A new imaging system for digital subtraction angiography (DSA) was evaluated in 30 clinical studies. The image receptor is a 25 X 25 cm, 12 par gadolinium oxysulfate rare-earth screen whose light output is focused to a low-light-level Isocon camera. The video signal is digitized and processed by an image-array processor containing 31 512 X 512 memories 8 bits deep. In most patients, intraarterial DSA studies were done in conjunction with conventional arteriography. In these arterial studies, images adequate to make a specific diagnosis were obtained using half the radiation dose and half the amount of contrast material needed for conventional angiography. In eight intravenous studies performed either to identify renal artery stenosis or for evaluation of congenital heart anomalies, the images were diagnostic but objectionably noisy

  4. Intracranial arterial anatomy: evaluation by computed tomography angiography

    International Nuclear Information System (INIS)

    Regattieri, Neysa Aparecida Tinoco; Haetinger, Rainer Guilherme; Liberti, Edson Aparecido

    2010-01-01

    By many decades, the intracranial arteries study was realized exclusively by angiography through selective arterial catheterization. Nowadays, with the technologic evaluation of computerized tomography devices with multi detectors allowing acquisitions with even more thinner slices, higher speed and better resolution, it had appeared a new modality of investigation: the computed tomography angiography, less invasive and with minor morbidity than conventional arteriography. Many studies in the literature have been analyzing the sensibility of the new method for the detection of intracranial aneurysms and comparing them with the conventional arteriography. There is a necessity to recognize the normal intracranial arterial anatomy and its variations using images obtained from multiplanar reformations, in order to give important information for surgeries strategies, such as wall calcifications, aneurismatic neck position and relationships with surrounding anatomical structures. (author)

  5. Intraoperative seizures and seizures outcome in patients underwent awake craniotomy.

    Science.gov (United States)

    Yuan, Yang; Peizhi, Zhou; Xiang, Wang; Yanhui, Liu; Ruofei, Liang; Shu, Jiang; Qing, Mao

    2016-11-25

    Awake craniotomies (AC) could reduce neurological deficits compared with patients under general anesthesia, however, intraoperative seizure is a major reason causing awake surgery failure. The purpose of the study was to give a comprehensive overview the published articles focused on seizure incidence in awake craniotomy. Bibliographic searches of the EMBASE, MEDLINE,were performed to identify articles and conference abstracts that investigated the intraoperative seizure frequency of patients underwent AC. Twenty-five studies were included in this meta-analysis. Among the 25 included studies, one was randomized controlled trials and 5 of them were comparable studies. The pooled data suggested the general intraoperative seizure(IOS) rate for patients with AC was 8%(fixed effect model), sub-group analysis identified IOS rate for glioma patients was 8% and low grade patients was 10%. The pooled data showed early seizure rates of AC patients was 11% and late seizure rates was 35%. This systematic review and meta-analysis shows that awake craniotomy is a safe technique with relatively low intraoperative seizure occurrence. However, few RCTs were available, and the acquisition of further evidence through high-quality RCTs is highly recommended.

  6. Diagnostic accuracy of dual energy CT angiography in patients with diabetes mellitus; Diagnostische Genauigkeit der Dual-energy-CT-Angiographie bei Patienten mit Diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Schabel, C.; Bongers, M.N.; Syha, R. [Klinikum der Eberhard-Karls-Universitaet, Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Klinikum der Eberhard-Karls-Universitaet, Sektion fuer Experimentelle Radiologie der Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Ketelsen, D.; Homann, G.; Notohamiprodjo, M.; Nikolaou, K.; Bamberg, F. [Klinikum der Eberhard-Karls-Universitaet, Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Thomas, C. [Universitaetsklinikum Duesseldorf, Abteilung fuer Diagnostische und Interventionelle Radiologie, Duesseldorf (Germany)

    2015-04-01

    Peripheral arterial disease (PAD) represents a major and highly prevalent complication in patients with diabetes mellitus. The diagnostic, non-invasive work-up by computed tomography angiography (CTA) is limited in the presence of extensive calcification. The aim of the study was to determine the diagnostic accuracy of dual energy CTA (DE-CTA) for the detection and characterization of PAD in patients with diabetes mellitus. In this study 30 diabetic patients with suspected or known PAD were retrospectively included in the analysis. All subjects underwent DE-CTA (Somatom Definition Flash, Siemens Healthcare, Erlangen, Germany) prior to invasive angiography, which served as the reference standard. Blinded analysis included assessment of the presence and degree of peripheral stenosis on curved multiplanar reformatting (MPR) and maximum intensity projections (MIP). Conventional measures of diagnostic accuracy were derived. Among the 30 subjects included in the analysis (83 % male, mean age 70.0 ± 10.5 years, 83 % diabetes type 2), the prevalence of critical stenosis in 331 evaluated vessel segments was high (30 %). Dual energy CT identified critical stenoses with a high sensitivity and good specificity using curved MPR (100 % and 93.1 %, respectively) and MIP images (99 % and 91.8 %, respectively). In stratified analysis, the diagnostic accuracy was higher for stenosis pertaining to the pelvic and thigh vessels as compared with the lower extremities (curved MPR accuracy 97.1 % vs. 99.2 vs. 90.9 %; respectively, p < 0.001). The use of DE-CTA allows reliable detection and characterization of peripheral arterial stenosis in patients with diabetes mellitus with higher accuracy in vessels in the pelvic and thigh regions compared with the vessels in the lower legs. (orig.) [German] Die periphere arterielle Verschlusskrankheit (PAVK) ist eine wesentliche Komplikation des Diabetes mellitus und stellt aufgrund ausgepraegter Gefaessverkalkungen eine diagnostische

  7. Multislice CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, Mathias E-mail: mathias.prokop@univie.ac.at

    2000-11-01

    Multislice CT has overcome past limitations of CT angiography (CTA): Scan length and spatial resolution can be simultaneously optimized with multislice CTA, contrast medium can be saved, and the evaluation of large anatomic areas and vessels smaller than 1 mm become possible. This article describes how to optimize scanning protocols and contrast injection, and discusses the main clinical applications of this new technique. Only three main scanning protocolssuffice for all indications. A high speed / high-volume protocol (using 4*2mm or 4*2.5mm collimation) can be employed to scan the chest or abdomen in 8-10s, or to cover the whole abdominal aorta and the peripheral runoff including the feet within 40-65s. A high resolution protocol (using 4*1mm or 4*1.25mm) can be employed for the aorta and most regional vascular beds. It allows for near isotrophic imaging and depicts fine vascular structures with excellent detail. Ultra-high resolution protocols (using 2*0.5mm or 4*0.5mm collimation) yield totally isotropic data sets, and are mainly reserved for cerebrovascular imaging. Image processing techniques, and, in particular, volume rendering have made image presentation faster and easier. Multislice CTA exceeds MRA in spatial resolution and is now able to display even small vascular side branches. Its main indications will be aortic diseases, suspected pulmonary embolism but also renal artery stenoses, preoperative workup of abdominal or cerebral vessels, and acute vascular diseases. Multisplice CTA will become a strong competitor of other minimally invasive vascular imaging techniques.

  8. Treatment of arteriovenous malformations with stereotactic radiosurgery employing both magnetic resonance angiography and standard angiography as a database

    International Nuclear Information System (INIS)

    Petereit, D.; Mehta, M.; Turski, P.; Levin, A.; Strother, C.; Mistretta, C.; Mackie, R.; Gehring, M.; Kubsad, S.; Kinsella, T.

    1993-01-01

    Twenty-one arteriovenous malformations were prospectively evaluated using magnetic resonance angiography, compare it to stereotactic angiography, employ magnetic resonance angiography in follow-up, and semiquanitfy flow. A correlative evaluation between flow and response to stereotactic radiosurgery was carried out. Phase contrast angiograms were obtained at flow velocities of 400, 200, 100, 60 and 20 cm/sec. The fractionated velocities provided images that selectively demonstrated the arterial and venous components of the arteriovenous malformations. Qualitative assessment of the velocity within the arteriovenous malformations and the presence of fistulae were also determined by multiple velocity images. In addition, 3-dimensional time-of-flight magnetic resonance angiograms were obtained to define the exact size and shape of the nidus. This technique also permitted evaluation of the nidus and feeding arteries for the the presence of low flow aneurysms. Correlation between the two imaging modalities was carried out by subjective and semiquantitative estimation of flow velocity and estimation of nidus size. The following velocity parameters were employed: fast, intermediate, slow, and none. Early analysis suggests that slower flowing arteriovenous malformations may obliterate faster after stereotactic radiosurgery an flow parameters should be employed to predict response. In conclusion, magnetic resonance angiography permits semiquantitative flow velocity assessment and may therefore be superior to stereotactic angiography. An additional advantage of magnetic resonance angiography is the generation of serial transverse images which can replace the conventional CT scan employed for stereotactic radiosurgery treatment planning. A single diagnostic test may therefore be used for diagnosis, radiosurgical treatment planning, follow-up, and treatment selection by identifying patients likely to respond early to radiosurgical management

  9. Evaluation of the pulmonary vascular bed by digital subtraction angiography

    International Nuclear Information System (INIS)

    Shikuwa, Masahiro; Asai, Sadahiro; Hara, Shiro; Yamasa, Toshihiko; Miyahara, Yoshiyuki; Hara, Kohei; Nishijima, Kyoji.

    1995-01-01

    We studied the usefulness of digital subtraction angiography for evaluating the pulmonary capillary bed. Four individuals underwent the procedure. One was a healthy volunteer and the others were patients with chronic pulmonary emphysema. During catheterization, an 8 F balloon catheter was manipulated into the right pulmonary artery. A total of 20 ml of contrast material was injected at a rate of 10 ml/sec at full inspiration. In the normal subject, the capillary bed filled homogeneously and no defect was seen. In the patients, the pulmonary artery was nearly normal, but severe defects were observed in the pulmonary capillaries. Contrast resolvability was greater with digital subtraction pulmonary angiography than with pulmonary perfusion scintigraphy or pulmonary arteriography. This technique makes possible the visual evaluation of the pulmonary capillary bed. (author)

  10. Atherosclerosis of the carotid artery: evaluation by magnetic resonance angiography.

    Science.gov (United States)

    Wildy, K S; Yuan, C; Tsuruda, J S; Ferguson, M S; Wen, N; Subramaniam, D S; Strandness, D E

    1996-01-01

    Carotid artery atherosclerotic plaques (APs) can lead to brain ischemia, an event shown to correlate with both the degree of stenosis and the composition of the AP. Currently, accurate estimates of stenosis can be obtained by either x-ray angiography or three-dimensional time-of-flight (TOF) magnetic resonance angiography (MRA). Our purpose was to determine whether three-dimensional TOF MRA images could also provide information on plaque location, morphology, and composition. Seven pre-endarterectomy patients underwent three-dimensional TOF MRA. After endarterectomy, plaque histology was evaluated. Three-dimensional TOF MRA images contained sufficient soft tissue contrast to differentiate the plaques from the surrounding tissues in all cases. Estimation of plaque morphology had 80% correlation with histology. Finally, intraplaque hemorrhage and calcification were deplicted as regions of moderately high and very low intensity, respectively. These preliminary results suggest that three-dimensional TOF MRA may be useful in studying the development and progression of carotid atherosclerosis.

  11. Impact of routine cerebral CT angiography on treatment decisions in infective endocarditis.

    Directory of Open Access Journals (Sweden)

    Marwa Sayed Meshaal

    Full Text Available Infective endocarditis (IE is commonly complicated by cerebral embolization and hemorrhage secondary to intracranial mycotic aneurysms (ICMAs. These complications are associated with poor outcome and may require diagnostic and therapeutic plans to be modified. However, routine screening by brain CT and CT angiography (CTA is not standard practice. We aimed to study the impact of routine cerebral CTA on treatment decisions for patients with IE.From July 2007 to December 2012, we prospectively recruited 81 consecutive patients with definite left-sided IE according to modified Duke's criteria. All patients had routine brain CTA conducted within one week of admission. All patients with ICMA underwent four-vessel conventional angiography. Invasive treatment was performed for ruptured aneurysms, aneurysms ≥ 5 mm, and persistent aneurysms despite appropriate therapy. Surgical clipping was performed for leaking aneurysms if not amenable to intervention.The mean age was 30.43 ± 8.8 years and 60.5% were males. Staph aureus was the most common organism (32.3%. Among the patients, 37% had underlying rheumatic heart disease, 26% had prosthetic valves, 23.5% developed IE on top of a structurally normal heart and 8.6% had underlying congenital heart disease. Brain CT/CTA revealed that 51 patients had evidence of cerebral embolization, of them 17 were clinically silent. Twenty-six patients (32% had ICMA, of whom 15 were clinically silent. Among the patients with ICMAs, 11 underwent endovascular treatment and 2 underwent neurovascular surgery. The brain CTA findings prompted different treatment choices in 21 patients (25.6%. The choices were aneurysm treatment before cardiac surgery rather than at follow-up, valve replacement by biological valve instead of mechanical valve, and withholding anticoagulation in patients with prosthetic valve endocarditis for fear of aneurysm rupture.Routine brain CT/CTA resulted in changes in the treatment plan in a significant

  12. Diagnostic performance of computed tomography coronary angiography (from the Prospective National Multicenter Multivendor EVASCAN Study).

    Science.gov (United States)

    Gueret, Pascal; Deux, Jean-François; Bonello, Laurent; Sarran, Anthony; Tron, Christophe; Christiaens, Luc; Dacher, Jean-Nicolas; Bertrand, David; Leborgne, Laurent; Renard, Cedric; Caussin, Christophe; Cluzel, Philippe; Helft, Gerard; Crochet, Dominique; Vernhet-Kovacsik, Hélène; Chabbert, Valérie; Ferrari, Emile; Gilard, Martine; Willoteaux, Serge; Furber, Alain; Barone-Rochette, Gilles; Jankowski, Adrien; Douek, Philippe; Mousseaux, Elie; Sirol, Marc; Niarra, Ralph; Chatellier, Gilles; Laissy, Jean-Pierre

    2013-02-15

    Computed tomographic coronary angiography (CTCA) has been proposed as a noninvasive test for significant coronary artery disease (CAD), but only limited data are available from prospective multicenter trials. The goal of this study was to establish the diagnostic accuracy of CTCA compared to coronary angiography (CA) in a large population of symptomatic patients with clinical indications for coronary imaging. This national, multicenter study was designed to prospectively evaluate stable patients able to undergo CTCA followed by conventional CA. Data from CTCA and CA were analyzed in a blinded fashion at central core laboratories. The main outcome was the evaluation of patient-, vessel-, and segment-based diagnostic performance of CTCA to detect or rule out significant CAD (≥50% luminal diameter reduction). Of 757 patients enrolled, 746 (mean age 61 ± 12 years, 71% men) were analyzed. They underwent CTCA followed by CA 1.7 ± 0.8 days later using a 64-detector scanner. The prevalence of significant CAD in native coronary vessels by CA was 54%. The rate of nonassessable segments by CTCA was 6%. In a patient-based analysis, sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios of CTCA were 91%, 50%, 68%, 83%, 1.82, and 0.18, respectively. The strongest predictors of false-negative results on CTCA were high estimated pretest probability of CAD (odds ratio [OR] 1.97, p <0.001), male gender (OR 1.5, p <0.002), diabetes (OR 1.5, p <0.0001), and age (OR 1.2, p <0.0001). In conclusion, in this large multicenter study, CTCA identified significant CAD with high sensitivity. However, in routine clinical practice, each patient should be individually evaluated, and the pretest probability of obstructive CAD should be taken into account when deciding which method, CTCA or CA, to use to diagnose its presence and severity. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Diagnostic accuracy of dual energy CT angiography in patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Schabel, C.; Bongers, M.N.; Syha, R.; Ketelsen, D.; Homann, G.; Notohamiprodjo, M.; Nikolaou, K.; Bamberg, F.; Thomas, C.

    2015-01-01

    Peripheral arterial disease (PAD) represents a major and highly prevalent complication in patients with diabetes mellitus. The diagnostic, non-invasive work-up by computed tomography angiography (CTA) is limited in the presence of extensive calcification. The aim of the study was to determine the diagnostic accuracy of dual energy CTA (DE-CTA) for the detection and characterization of PAD in patients with diabetes mellitus. In this study 30 diabetic patients with suspected or known PAD were retrospectively included in the analysis. All subjects underwent DE-CTA (Somatom Definition Flash, Siemens Healthcare, Erlangen, Germany) prior to invasive angiography, which served as the reference standard. Blinded analysis included assessment of the presence and degree of peripheral stenosis on curved multiplanar reformatting (MPR) and maximum intensity projections (MIP). Conventional measures of diagnostic accuracy were derived. Among the 30 subjects included in the analysis (83 % male, mean age 70.0 ± 10.5 years, 83 % diabetes type 2), the prevalence of critical stenosis in 331 evaluated vessel segments was high (30 %). Dual energy CT identified critical stenoses with a high sensitivity and good specificity using curved MPR (100 % and 93.1 %, respectively) and MIP images (99 % and 91.8 %, respectively). In stratified analysis, the diagnostic accuracy was higher for stenosis pertaining to the pelvic and thigh vessels as compared with the lower extremities (curved MPR accuracy 97.1 % vs. 99.2 vs. 90.9 %; respectively, p < 0.001). The use of DE-CTA allows reliable detection and characterization of peripheral arterial stenosis in patients with diabetes mellitus with higher accuracy in vessels in the pelvic and thigh regions compared with the vessels in the lower legs. (orig.) [de

  14. CT angiography versus 3D rotational angiography in patients with subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Bechan, R.S.; Peluso, J.P.; Sluzewski, M.; Rooij, W.J. van [Sint Elisabeth Ziekenhuis Tilburg, Department of Radiology, Tilburg (Netherlands); Rooij, S.B. van [Medisch Centrum Alkmaar, Department of Radiology, Alkmaar (Netherlands); Sprengers, M.E.; Majoie, C.B. [Academisch Medisch Centrum, Department of Radiology, Amsterdam (Netherlands)

    2015-12-15

    CT angiography (CTA) is increasingly used as primary diagnostic tool to replace digital subtraction angiography (DSA) in patients with subarachnoid hemorrhage (SAH). However, 3D rotational angiography (3DRA) has substituted DSA as a reference standard. In this prospective observational study, we compare CTA with 3DRA of all cerebral vessels in a large cohort of patients with SAH. Of 179 consecutive patients with SAH admitted between March 2013 and July 2014, 139 underwent 64- to 256-detector row CTA followed by complete cerebral 3DRA within 24 h. In 86 patients (62 %), 3DRA was performed under general anesthesia. Two observers from outside hospitals reviewed CTA data. In 118 of 139 patients (85 %), 3DRA diagnosed the cause of hemorrhage: 113 ruptured aneurysms, three arterial dissections, one micro-arteriovenous malformation (AVM), and one reversible vasoconstriction syndrome. On CTA, both observers missed all five non-aneurysmal causes of SAH. Sensitivity of CTA in depicting ruptured aneurysms was 0.88-0.91, and accuracy was 0.88-0.92. Of 113 ruptured aneurysms, 28 were ≤3 mm (25 %) and of 95 additional aneurysms, 71 were ≤3 mm (75 %). Sensitivity of depicting aneurysms ≤3 mm was 0.28-0.43. Of 95 additional aneurysms, the two raters missed 65 (68 %) and 58 (61 %). Sensitivity in detection was lower in aneurysms of the internal carotid artery than in other locations. CTA had some limitations as primary diagnostic tool in patients with SAH. All non-aneurysmal causes for SAH and one in ten ruptured aneurysms were missed. Performance of CTA was poor in aneurysms ≤3 mm. The majority of additional aneurysms were not depicted on CTA. (orig.)

  15. Fluorescence angiography in retinal tumours

    International Nuclear Information System (INIS)

    Fuhrmann, M.

    1980-01-01

    On the basis of the available photographic material the results of fluorescein angiography are reported in 4 cases of retinoblastoma and 3 cases of Bourneville's disease. The clinical diagnosis of retinoblastoma was confirmed histologically in all cases since the first eye had been removed for the same reason previously. One child had not yet been treated, and in 3 cases radioactive isotopes were used in the treatment. In the group of phacomatosis the patients had only periodical outpatient examinations. The importance of this angiography in the diagnosis and follow-up of these diseases is stressed. (author)

  16. Fluorescence angiography in retinal tumours

    Energy Technology Data Exchange (ETDEWEB)

    Fuhrmann, M [Staedtisches Klinikum Berlin-Buch (German Democratic Republic)

    1980-01-01

    On the basis of the available photographic material the results of fluorescein angiography are reported in 4 cases of retinoblastoma and 3 cases of Bourneville's disease. The clinical diagnosis of retinoblastoma was confirmed histologically in all cases since the first eye had been removed for the same reason previously. One child had not yet been treated, and in 3 cases radioactive isotopes were used in the treatment. In the group of phacomatosis the patients had only periodical outpatient examinations. The importance of this angiography in the diagnosis and follow-up of these diseases is stressed.

  17. MDCT angiography and transcatheter embolization in management ...

    African Journals Online (AJOL)

    Hassan Abdelsalam

    2015-12-18

    Dec 18, 2015 ... 14 patients did not have a MDCT and proceeded straight to angiography;. 6 of them showed active bleeding on angiography. Conclusion: MDCT is an excellent technique before angiography and embolization in cases with acute gastrointestinal bleeding. Transcatheter embolization is an effective tool for ...

  18. The value of coronary artery calcium score assessed by dual-source computed tomography coronary angiography for predicting presence and severity of coronary artery disease

    International Nuclear Information System (INIS)

    Almasi, Alireza; Pouraliakbar, Hamidreza; Sedghian, Ahmad; Karimi, Mohammad Ali; Firouzi, Ata; Tehrai, Mahmood

    2014-01-01

    Measuring coronary artery calcium score (CACS) using a dual-source CT scanner is recognized as a major indicator for assessing coronary artery disease. The present study aimed to validate the clinical significance of CACS in predicting coronary artery stenosis and its severity. This prospective study was conducted on 202 consecutive patients who underwent both conventional coronary angiography and dual-source (256-slice) computed tomography coronary angiography (CTA) for any reason in our cardiac imaging center from March to September 2013. CACS was measured by Agatston algorithm on non-enhanced CT. The severity of coronary artery disease was assessed by Gensini score on conventional angiography. There was a significant relationship between the number of diseased coronary vessels and mean calcium score, i.e. the mean calcium score was 202.25±450.06 in normal coronary status, 427.50±607.24 in single-vessel disease, 590.03±511.34 in two-vessel disease, and 953.35±1023.45 in three-vessel disease (p<0.001). There was a positive association between calcium score and Gensini score (r=0.636, p<0.001). In a linear regression model, calcium score was a strong determinant of the severity of coronary artery disease. Calcium scoring had an acceptable value for discriminating coronary disease from normal condition with optimal cutoff point of 350, yielding a sensitivity and specificity of 83% and 70%, respectively. Our study confirmed the strong relationship between the coronary artery calcium score and the presence and severity of stenosis in coronary arteries assessed by both the number of diseased coronary vessels and also by the Gnesini score

  19. Digital subtraction cardiopulmonary angiography using FCR (Fuji computed radiography)

    International Nuclear Information System (INIS)

    Tanimura, Shigeo; Tomoyasu, Hiroshi; Banba, Jiro; Masaki, Mikio; Kanno, Yukio; Abe, Kazuo

    1987-01-01

    Digital subtraction cardiopulmonary angiography using FCR was performed on 46 patients including lung cancer, mediastinal tumor, giant bullous formation and others. The images of digital subtraction for pulmonary artery, pulmonary vein and thoracic aorta were studied by comparing to the conventional pulmonary angiogram. Good images of pulmonary artery due to digital subtraction were obtained in 80 % of the 45 cases. This method needed only half volume of contrast media compared to the conventional for obtaining good images and thus reduced side effect. Therefore this method seems to be an usefull pre-operative examination in various chest diseases, especially in case of lung cancer. (author)

  20. Digital subtraction angiography in traumatology

    International Nuclear Information System (INIS)

    Steudel, A.; Harder, T.; Lackner, K.; Schneider, B.; Orellano, L.; Bonn Univ.; Bonn Univ.

    1986-01-01

    The methods, indications and results of digital subtraction angiography in traumatology are presented, based on 56 examinations. The different use of intravenous or intraarterial DSA will be discussed with respect to expanding and localisation of traumatic vascular injury. DSA is recommended as the method of choice for follow-up after vascular reconstructive procedure. (orig.) [de

  1. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France); University Bordeaux Segalen, Bordeaux Cedex (France); Bullier, Eric; Riviere, Annalisa [Hopital Haut-Leveque, CHU Bordeaux, Department of Nuclear Medicine, Pessac (France); Dromer, Claire [Hopital Haut-Leveque, CHU Bordeaux, Department of Respiratory Diseases, Pessac (France); Picard, Francois [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiology, Pessac (France); Billes, Marc-Alain [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiac Surgery, Pessac (France); Corneloup, Olivier [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France)

    2014-01-15

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  2. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    International Nuclear Information System (INIS)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu; Bullier, Eric; Riviere, Annalisa; Dromer, Claire; Picard, Francois; Billes, Marc-Alain; Corneloup, Olivier

    2014-01-01

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  3. Risk of renal allograft rejection following angiography

    International Nuclear Information System (INIS)

    Heideman, M.; Claes, G.; Nilson, A.E.

    1976-01-01

    In a retrospective study of 173 immediately functioning primary kidney transplants, correlation between angiography and renal allograft rejection was studied during the first 14 days. It was found that rejection was more frequent in kidneys undergoing angiography than in those not undergoing angiography. It was also found that in kidneys undergoing angiography an overwhelming number of the rejections started the day after angiography. These differences in rejection frequency could not be explained by differences in HLA matching or the origin of the kidneys. These findings suggest a possible connection indicating that the angiography might elicit an acute rejection episode. A possible mechanism for starting this reaction might be activation of the complement system which was found in 50 percent of the patients undergoing angiography in peripheral blood and in 100 percent when studied in vitro

  4. Dumping convention

    International Nuclear Information System (INIS)

    Roche, P.

    1992-01-01

    Sea dumping of radioactive waste has, since 1983, been precluded under a moratorium established by the London Dumping Convention. Pressure from the nuclear industry to allow ocean dumping of nuclear waste is reported in this article. (author)

  5. Impact of Collateral Status Evaluated by Dynamic Computed Tomographic Angiography on Clinical Outcome in Patients With Ischemic Stroke.

    Science.gov (United States)

    van den Wijngaard, Ido R; Boiten, Jelis; Holswilder, Ghislaine; Algra, Ale; Dippel, Diederik W J; Velthuis, Birgitta K; Wermer, Marieke J H; van Walderveen, Marianne A A

    2015-12-01

    Status of collateral circulation is a strong predictor of outcome after acute ischemic stroke. Our aim was to compare the predictive value of strategies for collateral blood flow assessment with dynamic computed tomographic angiography (CTA) and conventional single-phase CT angiography. Patients with a proximal middle cerebral artery occlusion underwent noncontrast CT, single-phase CTA and whole brain CT perfusion/dynamic CTA within 9 hours after stroke onset. We defined poor outcome as a score on the modified Rankin Scale score of ≥3. The association between collateral score and clinical outcome at 3 months was analyzed with Poisson regression. The prognostic value of collateral scoring with dynamic CTA and single-phase CTA in addition to age, stroke severity, and noncontrast CT was assessed with logistic regression and summarized with the area under the curve. Seventy patients were included, with a mean age of 68 years. We observed an increased risk of poor outcome in patients with poor collaterals on single-phase CTA (risk ratio, 1.8; 95% confidence interval, 1.0-3.1) and on dynamic CTA (risk ratio, 2.0; 95% confidence interval, 1.5-2.7). The prediction of poor clinical outcome by means of collateral adjustment was better with dynamic CTA (area under the curve, 0.84; likelihood ratio test PCollateral assessment with dynamic CTA better predicts clinical outcome at 3 months than single-phase conventional CTA. URL: http://www.trialregister.nl/trialreg. Unique identifier: NTR1804. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00880113. © 2015 American Heart Association, Inc.

  6. Ischemic lesions related to cerebral angiography: Evaluation by diffusion weighted MR imaging

    International Nuclear Information System (INIS)

    Kato, Koki; Tomura, Noriaki; Takahashi, Satoshi; Sakuma, Ikuo; Watarai, Jiro

    2003-01-01

    We examined the incidence of ischemic lesions occurring after cerebral angiography by means of diffusion weighted MR imaging (DWI). Fifty patients were included in this study. Balloon occlusion tests of the internal carotid artery were performed in 9 of the 50 patients. DWI was performed on the same day as the cerebral angiography or on the following day. No new neurological deficits were found after cerebral angiography. However, 13 of the 50 cases revealed new ischemic lesions after cerebral angiography. The incidence of ischemic lesions was significantly different between patients who underwent balloon occlusion tests and patients who did not. The incidence of ischemic lesions was not influenced by the duration of the procedure, use of additional catheters, total amount of contrast material or the type of contrast material. The incidence of clinically silent ischemic lesions related to cerebral angiography is greater than the incidence of neurological complications. In patients who underwent occlusion tests of the internal carotid artery, the incidence of silent lesions was significantly higher than in patients who did not. (orig.)

  7. Digital subtraction angiography in the evaluation of chemodectomas

    International Nuclear Information System (INIS)

    Vlahos, L.; Papathanasiou, M.; Gouliamos, A.; Dimakakos, P.; Papavassiliou, C.

    1988-01-01

    During the last 2 years eleven patients with surgically confirmed chemodectomas have been investigated by means of digital subtraction angiography (DSA). Seven patients underwent i.v. DSA, which revealed eight carotid body tumours, and in the remaining four with jugulotympanic chemodectomas intra-arterial (i.a.) DSA was performed. We found i.v. DSA an easy and satisfactory method for the investigation of carotid body tumours but when glomus intravagale, tympanicum or jugulare is suspected an i.a. selective injection is required. (orig.) [de

  8. Digital subtraction angiography in the evaluation of chemodectomas

    Energy Technology Data Exchange (ETDEWEB)

    Vlahos, L.; Papathanasiou, M.; Gouliamos, A.; Dimakakos, P.; Papavassiliou, C.

    1988-05-01

    During the last 2 years eleven patients with surgically confirmed chemodectomas have been investigated by means of digital subtraction angiography (DSA). Seven patients underwent i.v. DSA, which revealed eight carotid body tumours, and in the remaining four with jugulotympanic chemodectomas intra-arterial (i.a.) DSA was performed. We found i.v. DSA an easy and satisfactory method for the investigation of carotid body tumours but when glomus intravagale, tympanicum or jugulare is suspected an i.a. selective injection is required.

  9. Characteristic findings of exercise ECG test, perfusion SPECT and coronary angiography in patients with exercise induced myocardial stunning

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Byeong Cheol; Seo, Ji Hyoung; Bae, Jin Ho; Jeong, Shin Young; Park, Hun Sik; Lee, Jae Tae; Chae, Shung Chull; Lee, Kyu Bo [School of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of)

    2004-06-01

    Transient wall motion abnormality and contractile dysfunction of the left ventricle (LV) can be observed in patients with coronary artery disease due to post-stress myocardial stunning. To understand clinical characteristics of stress induced LV dysfunction, we have compared the findings of exercise stress test, myocardial perfusion SPECT and coronary angiography between subjects with and without post-stress LV dysfunction. Among subjects who underwent exercise stress test, myocardial perfusion SPECT and coronary angiography within a month of interval, we enrolled 36 patients with post-stress LV ejection fraction (LVEF) was {>=}5% lower than rest (stunning group) and 16 patients with difference of post-stress and rest LVEF was lesser than 1% (non-stunning group) for this study. Treadmill exercise stress gated myocardial perfusion SPECT was performed with dual head SPECT camera using 740 MBq Tc-99m MIBI and coronary angiography was also performed by conventional Judkins method. Stunning group had a significantly higher incidence of hypercholesterolemia than non-stunning group(45.5 vs 7.1%, p=0.01). Stunning group also had higher incidence of diabetes mellitus and lower incidence of hypertension, but these were not statistically significant. Stunning group had larger and more severe perfusion defect in stress perfusion myocardial SPECT than non-stunning group(extent 18.2 vs 9.2%, p=0.029; severity 13.5 vs 6.9, p=0.040). Stunning group also had higher degree of reversibility of perfusion defect, higher incidence of positive exercise stress test and higher incidence of having severe stenosis(80{approx}99%) in coronary angiography than non-stunning group, but these were not statistically significant. In stunning group, all of 4 patients without perfusion defect had significant coronary artery stenosis and had received revascularization treatment. Patients with post-stress LV dysfunction had larger and more severe perfusion defect and severe coronary artery stenosis than

  10. Coronary angiography after successful thrombolysis - Is the recommended time interval of 24h an important issue?

    Science.gov (United States)

    Costa, Cátia; Durão, David; Belo, Adriana; Domingues, Kevin; Santos, Beatriz; Leal, Margarida

    2016-11-01

    Percutaneous coronary intervention (PCI) is currently considered the gold-standard treatment of acute coronary syndromes with ST-segment elevation (STEMI). However, this is not the reality of many European centers, where thrombolysis is performed as primary therapy. To determine, in a STEMI population that performed successful fibrinolytic treatment, if the performance of coronary angiography after the first 24h was associated with more hospital complications, including higher mortality, compared with its performance in the recommended time. Retrospective study, including 1065 patients with STEMI, who performed successful thrombolysis. The population was divided in three groups: A, patients who didn't undergo coronary angiography after successful thrombolysis (n=278; 26.1%); B, patients who underwent coronary angiography in the first 24h after successful thrombolysis (n=127; 11.9%); and C, patients who underwent angiography after the first 24h (n=660; 62.0%). Groups were compared regarding their characteristics and in-hospital complications. Groups B and C had more male patients and had younger patients than group A. Group A presented higher Killip classes at admission, more severe left ventricle dysfunction and a higher number of complications during hospitalization. Logistic regression revealed that: 1) the non-performance of coronary angiography after thrombolysis was an independent predictor of in-hospital mortality; and 2) the performance of angiography after the recommended time wasn't associated with higher mortality. Coronary angiography after thrombolysis constitutes an important strategy, whose non-performance carries worse prognosis. The time interval currently recommended of 24h seems clinically acceptable; however, its realization outside the recommended time doesn't seem to lead to higher mortality. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Intravenous digital angiography for the detection of renovascular hypertension

    International Nuclear Information System (INIS)

    Dunnick, N.R.; Svetkey, L.; Braun, S.D.; Cohan, R.H.; Newman, G.E.; Himmelstein, S.I.; Klotman, P.E.

    1987-01-01

    In order to assess the accuracy of intravenous digital subtraction angiography (IV-DSA), the authors prospectively studied all patients referred for suspected renovascular hypertension with IV-DSA and conventional angiography. The IV-DSA study demonstrated renal artery stenosis in 25 patients. A significant main renal artery lesion was confirmed in 21 of these patients while four patients had either normal renal arteries or insignificant changes. The IV-DSA examination was considered negative for renal artery stenosis in 50 patients. This was confirmed in 49 patients, but one patient had a branch renal artery stenosis. The sensitivity of IV-DSA was 96% while the specificity was 93%. The negative predictive value was 98% and the positive predictive value 84%. IV-DSA provides good anatomic definition of the main renal arteries and is sufficiently sensitive to be used as a screening test for renovascular hypertension

  12. Magnetic Resonance Angiography in the Pig using Hyperpolarized Water

    DEFF Research Database (Denmark)

    Lipsø, Hans Kasper Wigh; Bowen, Sean; Laustsen, Christoffer

    , the magnetization achievable with hyperpolarized water is superior to other nuclei. Methods A 1 mL sample of 50% water and 50% glycerol with 30 mM TEMPO is polarized in a Spinlab (GE Healthcare) at 5 T, 0.9 K, 139.9 GHz for an hour. The sample is rapidly dissolved in 16 mL deoxygenized dissolution medium (DM......Introduction Magnetic Resonance Angiography (MRA) is an important tool in diagnostics of medical conditions such as emboli, stenosis and aneurysms. Sub-millimetre resolution can be obtained with proton imaging, and further optimization can be obtained with Gd-based blood pool agents1. However......, the acquisition time is several minutes, and conventional MRA methods thus fail to image within a single respiration or heartbeat and therefore suffers from motion artefacts. We demonstrate that hyperpolarized (HP) water can be used as an imaging agent to provide subsecond angiographies in pigs. Previous work...

  13. Carotid stenosis: a comparison between MR and spiral CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Magarelli, N.; Carriero, A.; Bonomo, L. [Institute of Radiology, University ``G. D`Annunzio``, Chieti (Italy); Scarabino, T.; Simeone, A.L.; Florio, F. [IRCCS, Foggia (Italy); Salvolini, U. [Department of Neuroradiology, University of Ancona (Italy)

    1998-06-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.) With 6 figs., 4 tabs., 17 refs.

  14. Carotid stenosis: a comparison between MR and spiral CT angiography

    International Nuclear Information System (INIS)

    Magarelli, N.; Carriero, A.; Bonomo, L.; Scarabino, T.; Simeone, A.L.; Florio, F.; Salvolini, U.

    1998-01-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.)

  15. Physical principles of cardiac digital subtraction angiography

    International Nuclear Information System (INIS)

    Buonocore, E.; Pavlicek, W.

    1986-01-01

    Advances in the applications of computers with standard radiologic equipment have resulted in the development of electronic, or so-called ''film-less'' imaging. This technique, discussed by the authors, has become of particular value in the visualization of the central vascular system and has become known as digital subtraction angiography (DSA). Commercial products have become increasingly available and are capable of converting T.V. signals, obtained by conventional fluorography, to a computed array of digital values. Addition, subtraction, and averaging of this data, result in images with adequate signal-to-noise ratios that achieve detection of low concentrations of contrast media not possible with conventional screen film techniques. Computer subtraction of unnecessary background information improves the conspicuity of the opacified vessels to permit detection of vascular structures containing a concentration of no more than 1-3 percent of contrast media. This improved visualization is possible even with intravenous peripheral injections or reduced amounts of contrast media given intraarterially. With either method of contrast media administration, DSDA has become an excellent means of anatomic demonstration of the heart and great vessels with decreased morbidity and at lower cost

  16. Quantification of coronary artery calcium on the basis of dual-energy coronary CT angiography.

    Science.gov (United States)

    Schwarz, Florian; Nance, John W; Ruzsics, Balazs; Bastarrika, Gorka; Sterzik, Alexander; Schoepf, U Joseph

    2012-09-01

    To evaluate the feasibility of using virtual noncontrast material-enhanced (VNC) computed tomographic (CT) series derived from dual-energy CT imaging studies for coronary artery calcium quantification. This HIPAA-compliant study was institutional review board approved; all patients provided written informed consent. Thirty-six patients prospectively underwent noncontrast-enhanced CT calcium scoring followed by coronary CT angiography performed in dual-energy mode. By using different reconstruction algorithms, three VNC series were generated and evaluated for noise and efficiency of virtual iodine removal. Two readers independently quantified calcium on VNC images and true noncontrast-enhanced conventional calcium scoring series. A leave-one-out cross validation was used to assess the accuracy of calcium score prediction from VNC series by means of linear regression. CT value histograms of the VNC series closely resembled the profile in the true noncontrast-enhanced series. There was excellent correlation between calcium volumes on the VNC series and true noncontrast-enhanced series on a per-patient (r = 0.94, P VNC series was excellent (r = 0.82). Multiethnic Study of Atherosclerosis rankings that were derived from the predicted calcium scores also showed excellent agreement (intraclass correlation coefficient = 0.909). Coronary artery calcium identification and quantification based on dual-energy coronary CT angiographic studies may obviate the need for dedicated CT calcium scoring studies. © RSNA, 2012

  17. Comparative evaluation of 64-slice CT angiography and digital subtraction angiography in assessing the cervicocranial vasculature

    Directory of Open Access Journals (Sweden)

    Randolf Klingebiel

    2008-08-01

    Full Text Available Randolf Klingebiel1, Max Kentenich3, Hans-Christian Bauknecht3, Florian Masuhr2, Eberhard Siebert1, Markus Busch2, Georg Bohner11Department of Neuroradiology, 2Department of Neurology, 3Department of Radiology, Charité Universitary Medicine Berlin, GermanyBackground: Noninvasive 64-slice computed tomography angiography (64-MSCTA closely approximates conventional catheter angiography (DSA in terms of detail resolution. Objective: Retrospective evaluation of cervicocranial (cc 64-MSCTA in comparison with DSA in patients with presumptive cc vascular disorders.Material and methods: Twenty-four 64-MSCTA studies (32 mm detector width, slice thickness 0.5 mm, 120 kv, 150 mAs, pitch 0.75 of patients with presumptive cc vascular pathology (13 men, 11 women, mean age 38.3 ± 11.3 yrs, range 19–54 yrs were assessed in comparison with DSA studies without abnormal findings in age-matched patients (11 men, 13 women, mean age 39.7 ± 11.9 yrs, range 18–54 yrs. Study readings were performed in a blinded manner by two neuroradiologists with respect to image quality and assessibility of various cc vascular segments by using a five-point scale. Radiation exposure was calculated for 64-MSCTA.Results: Each reader assessed 384/528 different vessel segments (64-MSCTA/DSA. Superior image quality was attributed to DSA with respect to the C1 ICA–C6 ICA, A3 ACA, and P3 PCA segments as well the AICA and SCA. 64-MSCTA was scored superior for C7 ICA and V4 VA segments. A significantly increased number of nonassessable V2- and V3 VA segments in DSA studies was noted. The effective dose for 64-MSCTA amounted to 2.2 mSv.Conclusions: 64-MSCTA provides near-equivalent diagnostic information of the cc vasculature as compared with DSA. According to our results, DSA should be considered primarily when peripheral vessels (A3/P3 or ICA segments close to the skull base (C2-5 are of interest, such as in primary angiitis or stenoocclusive ICA disease, respectively.Keywords: CT-angiography

  18. Use of intraoperative cerebral and spinal digital angiography as an aid to vascular neurosurgery

    International Nuclear Information System (INIS)

    Joseph, G.J.; Barrow, D.L.; Hoffman, J.C.; O'Brien, M.K.

    1990-01-01

    This paper determines the utility of intraoperative digital subtraction angiography (IODSA) in evaluating completeness of resection/clipping of vascular abnormalities of the central nervous system. IODSA was performed in 61 patients undergoing resection of intracranial arteriovenous malformation (AVMs) (n = 25), aneurysms (n = 33), and spinal AVMs (n = 3). Results were reviewed immediately; if further surgery was required, additional studies were performed until resection was considered radiographically and surgically complete. All patients with AVM and 15 with aneurysm underwent postoperative angiography for confirmation of IODSA findings

  19. Rapid line scan MR angiography

    International Nuclear Information System (INIS)

    Frahm, J.; Merboldt, K.D.; Hanicke, W.; Bruhn, H.

    1987-01-01

    Direct MR angiography may be performed using line scan imaging techniques combined with presaturation of stationary spins. Thus, a single line scan echo yields a projection of vessels due to the signal from reflowing unsaturated spins. Reconstruction of an angiographic image is performed line by line at slightly incremented positions. In particular, line scan angiography is direct and fast without a sensitivity to artifacts even for high flow rates. Image resolution and field of view may be chosen without restrictions, and zoom images using enhanced gradients may be recorded without aliasing artifacts. The method is robust with respect to eddy currents and pulsatile flow. Line scan MR angiograms of phantoms, animals, and human volunteers have been recorded using 90 0 radio frequency pulses and gradient-recalled echoes

  20. Electrocardiographically gated snapshot MR angiography

    International Nuclear Information System (INIS)

    Brown, D.G.; Holsinger, A.E.; Riederer, S.J.

    1990-01-01

    The purpose of this paper is to evaluate the effectiveness of applying ultrashort (∼12 msec) TR times and measuring the central phase encodings first in improving the accuracy of vascular depiction in MR angiography. The imaging method combines ultrashort TR imaging techniques with time-of-flight MR angiography. The central phase-encoding views are acquired first, and an inversion-recovery contrast preparation pulse is applied prior to image acquisition to null signal from static tissues. In initial studies, the method was tested on phantoms and volunteers. The contrast-preparation phase effectively nulls static spins at the start of image acquisition. During the TL period fresh blood flows into the imaging section; even slowly moving blood is fully replaced

  1. Contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Bosmans, H.; Marchal, G.

    1996-01-01

    Despite many optimizations, the current limitations of plain MR angiography include: Saturation that impairs the visualization of veins and arteries with slow flow and spin-dephasing signal voids in locations with turbulent flow. Recently, the use of contrast agents has been proposed to cope with these remaining problems. Because of induced shortening of the T1 of the blood, saturation in the blood vessels is overcome. As a result, arteries and veins are visualized with the same signal intensity, which makes the technique less flow-dependent. In combination with short T1-weighted acquisitions, today CE MRA can be obtained while the patient is holding his breath. This last approach is most promising for abdominal applications since the respiratory motion can be frozen. As these acquisitions also use very short echo times, spin dephasing can be reduced. In conclusion, the use of contrast agents has greatly increased the clinical usefulness of MR angiography. (orig.) [de

  2. Multislice CT Angiography in Renal Artery Stent Evaluation: Prospective Comparison with Intra-Arterial Digital Subtraction Angiography

    International Nuclear Information System (INIS)

    Raza, Syed A.; Chughtai, Aamer R.; Wahba, Mona; Cowling, Mark G.; Taube, David; Wright, Andrew R.

    2004-01-01

    Purpose: To assess the role of multislice computed tomography angiography (MCTA) in the evaluation of renal artery stents, using intra-arterial digital subtraction angiography (DSA) as the gold standard. Methods: Twenty consecutive patients (15 men, 5 women) with 23 renal artery stents prospectively underwent both MCTA and DSA. Axial images, multiplanar reconstructions and maximum intensity projection images were used for diagnosis. The MCTA and DSA images were each interpreted without reference to the result of the other investigation. Results:The three cases of restenosis on DSA were detected correctly by MCTA; in 19 cases where MCTA showed a fully patent stent, the DSA was also negative. Sensitivity and negative predictive value (NPV) of MCTA were therefore 100%. In four cases, MCTA showed apparently minimal disease which was not shown on DSA. These cases are taken as false positive giving a specificity of 80% and a positive predictive value of 43%. Conclusion: The high sensitivity and NPV suggest MCTA may be useful as a noninvasive screen for renal artery stentrestenosis. MCTA detected mild disease in a few patients which was not confirmed on angiography

  3. Contrast-enhanced MR angiography vs intra-arterial digital subtraction angiography for carotid imaging: activity-based cost analysis

    International Nuclear Information System (INIS)

    U-King-Im, Jean Marie; Cross, Justin J.; Higgins, Nicholas J.; Graves, Martin J.; Antoun, Nagui M.; Gillard, Jonathan H.; Hollingworth, William; Trivedi, Rikin A.; Kirkpatrick, Peter J.

    2004-01-01

    The aim of this study was to compare the costs of performing contrast-enhanced MR angiography (CE MRA) with intra-arterial digital subtraction angiography (DSA) for the evaluation of carotid atherosclerotic disease. Activity-based cost analysis was used to identify the costs of performing each procedure. The variable direct costs of performing CE MRA and DSA were determined in 20 patients by using detailed time and motion studies. All personnel directly involved in the cases were tracked to the nearest minute and all consumable items used were recorded. Moreover, procedure times were prospectively recorded for an additional 80 patients who underwent both DSA and CE MRA. The variable direct costs of bed usage in the angiography day-case unit, all direct fixed costs as well as indirect costs were assessed from hospital and departmental accounting records. Total costs for each procedure were calculated and compared using Wilcoxon signed-rank sum test. Mean aggregate costs were and euro;721 for DSA and and euro;306 for CE MRA, resulting in potential savings of and euro;415 per patient (p<0.0001). On average, a DSA procedure thus cost approximately 2.4 (95% confidence intervals: 2.2-2.6) times more than CE MRA to our medical institution. Sensitivity analyses confirmed the robustness of our conclusions across wide ranges of plausible values for various parameters. Assuming equal diagnostic performance, institutions may have substantial cost savings if CE MRA is used instead of DSA for carotid imaging. (orig.)

  4. Contrast-enhanced MR angiography vs intra-arterial digital subtraction angiography for carotid imaging: activity-based cost analysis

    Energy Technology Data Exchange (ETDEWEB)

    U-King-Im, Jean Marie; Cross, Justin J.; Higgins, Nicholas J.; Graves, Martin J.; Antoun, Nagui M.; Gillard, Jonathan H. [University Department of Radiology, Addenbrooke' s Hospital, CB2 2QQ, Cambridge (United Kingdom); Hollingworth, William [Department of Radiology, University of Washington, WA 98103, Seattle (United States); Trivedi, Rikin A. [University Department of Radiology, Addenbrooke' s Hospital, CB2 2QQ, Cambridge (United Kingdom); Academic Department of Neurosurgery, Addenbrooke' s Hospital, CB2 2QQ, Cambridge (United Kingdom); Kirkpatrick, Peter J. [Academic Department of Neurosurgery, Addenbrooke' s Hospital, CB2 2QQ, Cambridge (United Kingdom)

    2004-04-01

    The aim of this study was to compare the costs of performing contrast-enhanced MR angiography (CE MRA) with intra-arterial digital subtraction angiography (DSA) for the evaluation of carotid atherosclerotic disease. Activity-based cost analysis was used to identify the costs of performing each procedure. The variable direct costs of performing CE MRA and DSA were determined in 20 patients by using detailed time and motion studies. All personnel directly involved in the cases were tracked to the nearest minute and all consumable items used were recorded. Moreover, procedure times were prospectively recorded for an additional 80 patients who underwent both DSA and CE MRA. The variable direct costs of bed usage in the angiography day-case unit, all direct fixed costs as well as indirect costs were assessed from hospital and departmental accounting records. Total costs for each procedure were calculated and compared using Wilcoxon signed-rank sum test. Mean aggregate costs were and euro;721 for DSA and and euro;306 for CE MRA, resulting in potential savings of and euro;415 per patient (p<0.0001). On average, a DSA procedure thus cost approximately 2.4 (95% confidence intervals: 2.2-2.6) times more than CE MRA to our medical institution. Sensitivity analyses confirmed the robustness of our conclusions across wide ranges of plausible values for various parameters. Assuming equal diagnostic performance, institutions may have substantial cost savings if CE MRA is used instead of DSA for carotid imaging. (orig.)

  5. Diagnostic accuracy of 64 multislice CT angiography in the assessment of coronary in-stent restenosis: A meta-analysis

    International Nuclear Information System (INIS)

    Sun Zhonghua; Almutairi, Abdulrahman Marzouq D.

    2010-01-01

    Purpose: The aim of this study was to perform a meta-analysis of the diagnostic accuracy of 64-slice CT angiography for the detection of coronary in-stent restenosis in patients treated with coronary stents when compared to conventional coronary angiography. Materials and methods: A search of PUBMED/MEDLINE, ProQuest and Cochrane library databases for English literature was performed. Only studies comparing 64-slice CT angiography with conventional coronary angiography for the detection of coronary in-stent restenosis (more than 50% stenosis) were included for analysis. Sensitivity and specificity estimates pooled across studies were tested using a fixed effects model. Results: Fourteen studies met selection criteria for inclusion in the analysis. The mean value of assessable stents was 89%. Prevalence of in-stent restenosis following coronary stenting was 20% among these studies. Pooled estimates of the sensitivity and specificity of overall 64-slice CT angiography for the detection of coronary in-stent restenosis was 90% (95% CI: 86%, 94%) and 91% (95% CI: 90%, 93%), respectively, based on the evaluation of assessable stents. Diagnostic value of 64-slice CT angiography was found to decrease significantly when the analysis was performed with inclusion of nonassessable segments in five studies, with pooled sensitivity and specificity being 79% (95% CI: 68%, 88%) and 81% (95% CI: 77%, 84%). Stent diameter is the main factor affecting the diagnostic value of 64-slice CT angiography. Conclusion: Our results showed that 64-slice CT angiography has high diagnostic value (both sensitivity and specificity) for detection of coronary in-stent restenosis based on assessable segments when compared to conventional coronary angiography.

  6. Angiography of the upper extremity

    International Nuclear Information System (INIS)

    Janevski, B.K.

    1982-01-01

    This thesis provides a description of the technical and medical aspects of arteriography of the upper extremity and an extensive analysis of the angiographic anatomy and pathology of 750 selective studies performed in more than 500 patients. A short historical review is provided of angiography as a whole and of arteriography of the hand in particular. The method of percutaneous transfemoral catheterization of the arteries of the upper extremity and particularly the arteries of the hand is considered, discussing the problems the angiographer encounters frequently, describing the angiographic complications which may occur and emphasizing the measures to keep them to a minimum. The use of vasodilators in hand angiography is discussed. A short description of the embryological patterns persisting in the arteries of the arm is included in order to understand the congenital variations of the arteries of the upper extremity. The angiographic patterns and clinical aspects of the most common pathological processes involving the arteries of the upper extremities are presented. Special attention is paid to the correlation between angiography and pathology. (Auth.)

  7. Indications for intra-arterial digital subtraction angiography (DSA) in vascular disease

    International Nuclear Information System (INIS)

    Neufang, K.F.R.; Friedmann, G.; Peters, P.E.; Moedder, U.

    1983-01-01

    Digital subtraction angiography (DSA), using a direct arterial route, diminishes the risk of the examination by reducing the contrast dose by about 75%, making the examination more rapid and making it less likely that catheters will have to be changed. At the same time superimposition is avoided, one of the advantages of selective catheterisation. In view of the low contrast dose, it is possible to carry out several examinations at one time and to use additional projections for intracranial and peripheral disease, thereby improving the diagnostic value of the examination. For certain problems, intra-arterial DSA is already able to replace conventional angiography. The small field size and poor spatial resolution still make conventional angiography necessary as the basic form of investigation in most other circumstances. (orig.) [de

  8. Posterior encephalopathy with vasospasm: MRI and angiography

    International Nuclear Information System (INIS)

    Weidauer, S.; Gaa, J.; Lanfermann, H.; Zanella, F.E.; Sitzer, M.; Hefner, R.

    2003-01-01

    Posterior encephalopathy is characterised by headache, impairment of consciousness, seizures and progressive visual loss. MRI shows bilateral, predominantly posterior, cortical and subcortical lesions with a distribution. Our aim was to analyse the MRI lesion pattern and angiographic findings because the pathophysiology of posterior encephalopathy is incompletely understood. We report three patients with clinical and imaging findings consistent with posterior encephalopathy who underwent serial MRI including diffusion-weighted imaging (DWI) and construction of apparent diffusion coefficient (ADC) maps, and four-vessel digital subtraction angiography (DSA). DWI revealed symmetrical subcortical and cortical parieto-occipital high signal. High and also low ADCs indicated probable vasogenic and cytotoxic oedema. On follow-up there was focal cortical laminar necrosis, while the white-matter lesions resolved almost completely, except in the arterial border zones. DSA revealed diffuse arterial narrowing, slightly more marked in the posterior circulation. These findings suggest that posterior encephalopathy may in some cases be due to diffuse, severe vasospasm affecting especially in the parieto-occipital grey matter, with its higher vulnerability to ischemia. Cerebral vasospasm due to digitoxin intoxication, resulting in posterior encephalopathy, has not yet been described previously. (orig.)

  9. Pulmonary CT angiography: optimization of contrast enhancement technique

    International Nuclear Information System (INIS)

    Ma Lianju; Tang Guangjian; Fu Jiazhen

    2012-01-01

    Objective: To derive and evaluate the formula of exactly calculating the contrast dosage used during pulmonary CT angiography (CTPA). Methods: Time density curves in 27 patients who underwent CTPA were collected and analyzed,the formula for calculating contrast dosage during CTPA was derived. 68 patients suspected of pulmonary embolism (PE) clinically but no PE on CTPA were divided randomly into group A, with bolus tracing technique (n=26), and group B, with small dose injection contrast test (SDCT) (n=42). The CT values of the right main pulmonary artery (RMPA), right upper pulmonary vein (RUPV), right posterior basal PA, right lower PV (RLPV) and the aorta were calculated. The total contrast dosage and the hard beam artifact in the SVC were compared between the two groups.Student's t test, Chi-square test and Mann-Whitney U test were used. Results: The ratio of the time from starting injection to enhancement peak of caudal end of SVC and the time to enhancement peak of the main pulmonary trunk was 0.65 ±0.09 (about 2/3), the formula for contrast dosage calculation was derived as (DTs/3 + STs/2) FR ml/s. The CT values of RMPA and RLPA between the two groups [(301 ±117), (329 ± 122) and (283 ±95), (277 ±98) HU respectively] were not significantly different (t=1.060, P=0.292; t=2.056, P=0.044), but the differences of CT values in the paired PA and PV between the two groups (median were 22.5, 58.0 and 170.5, 166.5 HU respectively) were significant (U=292, P=0.001 and U=325, P=0.005), contrast artifact of the SVC (grade 1-3) in group B (n=34, 7, 1 respectively) was significantly less than in group A (n=11, 10, 5 respectively, χ 2 =10.714, P=0.002), the contrast dosage injected in group A was ( 87.6 ± 7.3) ml, and in group B was (40.0 ±5.4) ml (P<0.01). Conclusion: CTPA with SDCT technique is superior to that with conventional bolus tracing technique regarding contrast dosage and contrast artifact in the SVC. (authors)

  10. Prediction of parent artery of anterior communicating artery aneurysm on CT angiography

    International Nuclear Information System (INIS)

    Chung, Jin Young; Han, Tae Il; Kim, Dae Hong; Han, Hyun Young; Kim, Hyun Jung; Song, Mun Kab

    1999-01-01

    To determine whether CT angiography can predict the parent artery of an anterior communicating aneurysm on the basis of characteristics of the aneurysm and precommunication anterior cerebral artery. Eighteen patients with anterior communication aneurysm were studied prospectively using CT angiography and conventional angiography. The parent artery of an aneurysm was predicted by evaluating aneurysm neck location, direction of aneurysm projection, and size of the precommunicating anterior cerebral artery, as seen on CT angiography. A somatom Plus-4 spiral CT scanner was used and shaded-surface display three-dimensional images were constructed. Aneurysm neck was located near the parent artery in 12 cases(66.7%), and aneurysm projection was against the parent artery in 11 cases(61.1%). The parent artery of the anterior cerebral artery was larger in 15 cases(83.3%), including ten cases of hypoplasia or agenesis of the contralateral anterior cerebral artery. In 17 of 18 aneurysms(94.4%) the parent artery seen on DSA was correctly predicted by CT angiography. The parent artery of an anterior communicating aneurysm can be predicted by evaluating aneurysm neck location, direction of aneurysm projection, and precommunicating anterior cerebral artery, as seen on CT angiography

  11. Contrast-enhanced magnetic resonance angiography of persistent fifth aortic arch in children

    International Nuclear Information System (INIS)

    Zhong, Yumin; Zhu, Ming; Sun, Aimin; Li, Yuhua; Jaffe, Richard B.; Gao, Wei

    2007-01-01

    Cine angiography and echocardiography have been utilized to diagnose congenital aortic arch anomalies. However, the visualization of great vessels by echocardiography is limited, while cine angiography requires cardiac catheterization with ionizing radiation. Contrast-enhanced magnetic resonance angiography (MRA) is a noninvasive modality suitable for visualization of congenital aortic arch anomalies. To evaluate the utility of contrast-enhanced MRA in the diagnosis of persistent fifth aortic arch, a rare congenital aortic arch anomaly, and to compare the diagnostic accuracy of MRA with that of echocardiography and cine angiography. In four pediatric patients, contrast-enhanced MRA studies were performed for diagnosing persistent fifth aortic arch. The findings of MRA were compared with echocardiographic findings and confirmed by cine angiography and operation. Transthoracic surface echocardiography noted an aberrant vessel arising from the ascending aorta in two of four patients; the etiology of this vessel was uncertain. In the other two patients a diagnosis of coarctation was made. Of the four patients, only one was diagnosed with interruption of the aortic arch. Contrast-enhanced MRA clarified uncertain echocardiographic findings, enabling the correct diagnosis of persistent fifth aortic arch with fourth aortic arch interruption in all four patients. Contrast-enhanced MRA is a safe, accurate, and fast imaging technique for the evaluation of persistent fifth aortic arch and may obviate the need for conventional cine angiography. Cardiac catheterization may be reserved for some types of complicated congenital heart disease and for obtaining hemodynamic information. (orig.)

  12. Hemifacial spasm; The value of vertebral angiography

    International Nuclear Information System (INIS)

    Yang, Hak Seok; Kim, Myung Soon; Han, Yong Pyo

    1992-01-01

    In order to evaluate the value of vertebral angiography in assesment of hemifacial spasm, We reviewed retrospectively the vertebral angiography of 28 patients (30 cases) with surgically proved hemifacial spasm but normal CT scans of posterior fossa. There were 9 males and 19 females. Angiography revealed vascular focus of hemifacial spasm located at anterior inferior cerebellar artery , posterior inferior cerebellar artery, and vertebral artery in 19, 9, and 2 cases respectively. Right side was involved in 20 cases. All involved vessels were elongated, tortuous, and dilated. In conclusion, vertebral angiography was valuable in evaluating hemifacial spasm of vascular origin in the posterior fossa

  13. Comparison of CT angiography and digital subtraction angiography in the evaluation of intracranial aneurysmal neck

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Baik, Seung Kug; Shin, Mi Jeong; Choi, Han Yong

    2001-01-01

    To compare the usefulness of three-dimensional multislice CT angiography(CTA) and digital subtraction angiography (DSA) in the evaluation of intracranial aneurysmal neck. Nineteen patients with intracranial aneurysm (23 cases) underwent DSA and subsequent CTA. Using a multislice CT scanner and the SSD(shaded surface display) technique, clipping, cutting and the MPR technique, three-dimensional images were obtained. These were (a) external, (b) internal, from the direction of the parent artery, (c) internal, from the direction of the aneurysmal dome, and (d) an aneurysmal cutting image. The CTA findings were retrospectively compared with the DSA images. Twenty aneurysms were small and three were large. In eleven cases aneurysm neck was small, in nine it was wide, and in three it was relatively wide. For aneurysmal neck evaluation, CTA was superior to DSA in six of nine wide-neck aneurysms and all three large-sized wide-neck aneurysms. In small neck aneurysms 8 of 11 cases and in relatively wide neck all 3 cases showed similarly good images by both modalities. Of the 23 cases demonstrated by four different images, 14 cases showed the best image in internal image from parent artery direction and 6 cases showed similarly good image in both aneurysmal cutting image and internal image from parent artery direction. In the evaluation of wide neck aneurysms, 7 of 9 cases showed the best image at internal image from parent artery direction, compared with other three different images. In two cases of aneurysms, calcification was visible in the aneurysmal wall, so it was difficult to evaluate the aneurysmal neck. CTA was superior to DSA in the evaluating the intracranial aneurysmal neck. CTA maybe an additional available modality to evaluate the aneurysmal neck which is difficult to detect by the DSA. And the information of intracranial aneurysmal neck through CTA will be of value in surgical and endovascular treatment

  14. Simplified techniques of cerebral angiography using a mobile X-ray unit and computed radiography

    International Nuclear Information System (INIS)

    Gondo, Gakuji; Ishiwata, Yusuke; Yamashita, Toshinori; Iida, Takashi; Moro, Yutaka

    1989-01-01

    Simplified techniques of cerebral angiography using a mobile X-ray unit and computed radiography (CR) are discussed. Computed radiography is a digital radiography system in which an imaging plate is used as an X-ray detector and a final image is displayed on the film. In the angiograms performed with CR, the spatial frequency components can be enhanced for the easy analysis of fine blood vessels. Computed radiography has an automatic sensitivity and a latitude-setting mechanism, thus serving as an 'automatic camera.' This mechanism is useful for radiography with a mobile X-ray unit in hospital wards, intensive care units, or operating rooms where the appropriate setting of exposure conditions is difficult. We applied this mechanism to direct percutaneous carotid angiography and intravenous digital subtraction angiography with a mobile X-ray unit. Direct percutaneous carotid angiography using CR and a mobile X-ray unit were taken after the manual injection of a small amount of a contrast material through a fine needle. We performed direct percutaneous carotid angiography with this method 68 times on 25 cases from August 1986 to December 1987. Of the 68 angiograms, 61 were evaluated as good, compared with conventional angiography. Though the remaining seven were evaluated as poor, they were still diagnostically effective. This method is found useful for carotid angiography in emergency rooms, intensive care units, or operating rooms. Cerebral venography using CR and a mobile X-ray unit was done after the manual injection of a contrast material through the bilateral cubital veins. The cerebral venous system could be visualized from 16 to 24 seconds after the beginning of the injection of the contrast material. We performed cerebral venography with this method 14 times on six cases. These venograms were better than conventional angiograms in all cases. This method may be useful in managing patients suffering from cerebral venous thrombosis. (J.P.N.)

  15. Experimental studies of renal blood flow by digitized functional angiography

    International Nuclear Information System (INIS)

    Buersch, J.H.; Ochs, C.; Hahne, H.J.; Heintzen, P.H.

    1985-01-01

    New techniques of digital image processing have been experimentally tested for the assessment of renal blood flow. The underlying principle in functional angiography is the extraction of flow parameters. Basically, density-time variations of the contrast medium are analayzed from to each picture element of a 256x256 matrix. The real-time acquisition rate of images was 25/sec. For the calculation of angiographic flow a PDP 11/40 computer was used to interactively perform a time dependent segmentation of the renal arteries and the aorta. Subsequently, volume flow was calculated in relative units for the specific vascular segments under study. 15 control angiograms were made in 5 animals with cardiac output ranging between 0.8 to 2.2l/min. Unilateral renal blood flow was calculated as 24+-3.4% of pre-renal aortic flow without systematic side differences. Reproducibility from repeated flow measurements showed an SD of +-1.8% of the individual pre-renal aortic flow. Renal flow was also measured in 3 animals with an experimentally created 50% flow reduction of the left kidney. Angiographic flow in the left renal artery dropped to 12+-2% of pre-renal flow. The present experimental data suggest that digital angiography has sufficient diagnostic capabilities for the detection of abnormal renal blood flow. The technique may serve as a useful diagnostic adjunct to conventional angiography and has the potential of assisting in the evaluation of renal vascular hypertension. (orig.) [de

  16. Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography

    International Nuclear Information System (INIS)

    Young, N.; Kingston, R.J.; Markson, G.; Dorsch, N.W.C.; McMahon, J.

    2001-01-01

    The goal of this study was to assess the usefulness of spiral CT angiography (CTA) with three- dimensional reconstructions in defining intracranial aneurysms, particularly around the Circle of Willis. Two hundred consecutive patients with angiographic and/or surgical correlation were studied between 1993 and 1998, with CTA performed on a GE HiSpeed unit and Windows workstation. The following clinical situations were evaluated: conventional CT suspicion of an aneurysm; follow-up of treated aneurysm remnants or of untreated aneurysms; subarachnoid haemorrhage (SAH) and negative angiography; family or past aneurysm history; and for improved definition of aneurysm anatomy. Spiral CTA detected 140 of 144 aneurysms, and an overall sensitivity of 97%, including 30 of 32 aneurysms 3 mm or less in size. In 38 patients with SAH and negative angiography, CTA found six of the seven aneurysms finally diagnosed. There was no significant artefact in 17 of 23 patients (74%) with clips. The specificity of CTA was 86% with 8 false-positive cases. Spiral CTA is very useful in demonstrating intracranial aneurysms. (orig.)

  17. 'Table step-shift DSA' for peripheral angiography

    International Nuclear Information System (INIS)

    Kojima, Kanji; Seo, Hiroyuki; Kawase, Yoshirou; Hino, Ichirou; Satou, Katashi; Takashima, Hitoshi; Ohkawa, Motoomi; Tamai, Toyosato; Tanabe, Masatada

    1987-01-01

    We developed a new technique of digital subtraction angiography (DSA) for peripheral angiography, which make it possible to obtain DSA images of two contiguous positions with a single injection of contrast material. It is made by the combination with DSA system (Toshiba Digiformer X-03A) and the angio-table with step-shift function (Toshiba CAT-FX), which is widely used in the conventional angiography for pelvis and lower extrimities. When DSA image of the first position is sufficiently demonstrated, the table is semi-automatically translated to the second position by the switching of the operator, observing TV-monitor. The images are stored into the digital image disc. DSA image of the second position can be given by the remasking method. We examined 40 times ''table step-shift DSA'' on 18 patients, which consist of 19 IVDSA with central injection and 21 IADSA for abdomen and lower leg. In 90 % and 72.5 % of images the procedure was diagnostic for the 1st and 2nd position respectively. The causes of nondiagnostic image were mostly from the prolonged blood flow and its difference in both sides. With this technique we could reduce the contrast material load and the time consumption of the examination. (author)

  18. Synchrotron-based intravenous cerebral angiography in a small animal model

    International Nuclear Information System (INIS)

    Kelly, Michael E; Schueltke, Elisabeth; Fiedler, Stephan; Nemoz, Christian; Guzman, Raphael; Corde, Stephanie; Esteve, Francois; LeDuc, Geraldine; Juurlink, Bernhard H J; Meguro, Kotoo

    2007-01-01

    K-edge digital subtraction angiography (KEDSA), a recently developed synchrotron-based technique, utilizes monochromatic radiation and allows acquisition of high-quality angiography images after intravenous administration of contrast agent. We tested KEDSA for its suitability for intravenous cerebral angiography in an animal model. Adult male New Zealand rabbits were subjected to either angiography with conventional x-ray equipment or synchrotron-based intravenous KEDSA, using an iodine-based contrast agent. Angiography with conventional x-ray equipment after intra-arterial administration of contrast agent demonstrated the major intracranial vessels but no smaller branches. KEDSA was able to visualize the major intracranial vessels as well as smaller branches in both radiography mode (planar images) and tomography mode. Visualization was achieved with as little as 0.5 ml kg -1 of iodinated contrast material. We were able to obtain excellent visualization of the cerebral vasculature in an animal model using intravenous injection of contrast material, using synchrotron-based KEDSA

  19. Diagnostic value of digital subtraction angiography (DSA) using TOSHIBA DIGIFORMER X in the cerebrospinal vascular diseases

    International Nuclear Information System (INIS)

    Ishikawa, Tatsuya; Nakagawa, Yoku; Sawamura, Yutaka; Kobayashi, Nobuaki; Nagashima, Masafumi; Kitaoka, Ken-ichi; Kitagawa, Michio; Itoh, Terufumi; Ohsato, Takao.

    1987-01-01

    Using TOSHIBA Digiformer X, digital subtraction angiography (DSA) was performed in 286 patients, in whom 229 patients of cerebro-spinal vascular disease was included. The authors emphasize the usefulness of DSA in cerebro-spinal vascular disease in relation to conventional angiography. DSA taken by single small dose injection of contrast medium into the ascending aorta clearly demonstrates not only aortic arch and thoracic major vessels, but also cervical vessels and all intracranial vessels. Therefore, we could rapidly understand gross dynamics of the circulation and obtain useful informations prior to catheterization to the selective artery. This advantage of DSA was particularly useful for occlusive vascular diseases. Gradual injection of small dose of contrast medium obviously reduced recoiling of the catheter tip, which enabled the selective angiography with setting of the tip of the catheter at the entrance of cervical major vessels without its sufficient inserion into the selective vessels. This advantage is particularly beneficial for the patients with severe arteriosclerosis who was found to be difficult for selective catheterization. In our experience, demonstration of a presence of aneurysm by DSA was possible in almost all cases of subarachnoid hemorrhage, although spatial resolution of DSA is said to be inferior to the conventional angiography. Real time display of DSA decreased the time required for examination and enabled repeated angiography. This advantage of DSA is especially useful for the patients with spinal arterio-venous malformation and thoracic outlet syndrome. (author)

  20. Magnetic resonance angiography: Physical principles and clinical applications

    International Nuclear Information System (INIS)

    Hausmann, R.; Mueller, E.

    1992-01-01

    Within the last four years magnetic resonance angiography (MRA) developed very rapidly towards a well accepted screening technique for vascular examinations as a fast add-on to conventional MR. This review describes the basic physical principles as well as the different methods like time-of-flight and phase-sensitive MRA for visualization of blood vessels. Different applications of 3D, 2D sequential and 3D multivolume MRA are shown from various regions of the head and body. A short outlock to quantitative flow measurments is given in the last chapter including some interesting applications of these techniques which show the still expanding potential of magnetic resonance. (orig.) [de

  1. Intra-arterial digital subtraction angiography of the carotid arteries

    International Nuclear Information System (INIS)

    Nakstad, P.; Bakke, S.J.; Kjartansson, O.; Nyhus, S.

    1986-01-01

    A cross-over test in intra-arterial digital subtraction angiography (IADSA) of the carotid arteries was performed in 50 patients to evaluate image quality and side-effects with iohexol and metrizoate injected at concentrations of 100 mg I/ml by hand. The image quality was excellent or good in all cases. Although the severity and the frequency of side-effects were higher with metrizoate, both contrast media were suitable for IADSA at this low concentration. No complications were seen. It was assumed that the risk with IADSA was less than that of conventional-selectivity and with small amounts of contrast media, as in this study. (orig.)

  2. Digital subtraction angiography (DSA) for acute pulmonary emboli

    International Nuclear Information System (INIS)

    Witte, H.; Grabbe, E.; Buecheler, E.

    1983-01-01

    The results of 49 DSAs (in 29 patients) are presented; these were performed for the diagnosis or follow-up of pulmonary emboli. The direct or indirect signs of pulmonary emboli, known to occur during conventional pulmonary angiography, were used as diagnostic criteria. In 47 examinations it was possible to make or to exclude the diagnosis unequivocally. The advantages of DSA make it desirable to use this method as the first form of examination in the diagnosis of acute, but not immediately life-threatening, pulmonary emboli. (orig.) [de

  3. Contemporary Patterns of Early Coronary Angiography Use in Patients With Non-ST-Segment Elevation Myocardial Infarction in the United States: Insights From the National Cardiovascular Data Registry Acute Coronary Treatment and Intervention Outcomes Network Registry.

    Science.gov (United States)

    Malta Hansen, Carolina; Wang, Tracy Y; Chen, Anita Y; Chiswell, Karen; Bhatt, Deepak L; Enriquez, Jonathan R; Henry, Timothy; Roe, Matthew T

    2018-02-26

    The study sought to characterize patient- and hospital-level variation in early angiography use among non-ST-segment elevation myocardial infarction (NSTEMI) patients. Contemporary implementation of guideline recommendations for early angiography use in NSTEMI patients in the United States have not been described. The study analyzed NSTEMI patients included in ACTION (Acute Coronary Treatment and Intervention Outcomes Network) registry (2012 to 2014) who underwent in-hospital angiography. Timing of angiography was categorized as early (≤24 h) vs. delayed (>24 h). The study evaluated factors associated with early angiography, hospital-level variation in early angiography use, and the relationship with quality-of-care measures. A total of 79,760 of 138,688 (57.5%) patients underwent early angiography. Factors most strongly associated with delayed angiography included weekend or holiday presentation, lower initial troponin ratio values, higher initial creatinine values, heart failure on presentation, and older age. Median hospital-level use of early angiography was 58.5% with wide variation across hospitals (21.7% to 100.0%). Patient characteristics did not differ substantially across hospitals grouped by tertiles of early angiography use (low, middle, and high). Hospitals in the highest tertile tended to more commonly use guideline-recommended medications and had higher defect-free care quality scores. In contemporary U.S. practice, high-risk clinical characteristics were associated with lower use of early angiography in NSTEMI patients; hospital-level use of early angiography varied widely despite few differences in case mix. Hospitals that most commonly utilized early angiography also had higher quality-of-care metrics, highlighting the need for improved NSTEMI guideline adherence. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. 3D-CT angiography. Intracranial arterial lesions

    Energy Technology Data Exchange (ETDEWEB)

    Asato, Mikio; Tong, X.Q.; Tamura, Shozo [Miyazaki Medical Coll., Kiyotake (Japan)] [and others

    1997-06-01

    Since its introduction, three dimensional CT angiography (3D-CTA) on spiral (helical) CT has played an important role in clinical imaging. Initially it was reported to be useful in depicting aortic abnormalities, afterwards the merit in detecting intracranial aneurysm by 3D-CTA was also described. We have investigated the usefullness of 3D-CTA in detecting patients of intracranial aneurysm as well as arterio-venous malformation (AVM), Moyamoya disease and stenosis of middle cerebral artery, meanwhile the MR angiography (MRA) and digital subtraction angiography (DSA) examination of these patients were also studied as comparison to the 3D-CTA results. The sensitivity and specificity on investigating intracranial aneurysm were similar with other reports so far. 3D-CTA was possible to identify the feeding artery, nidus and draining vein of AVM, although DSA showed higher detectability. Occlusion of internal carotid artery and post-operative anastomosis in Moyamoya disease were all demonstrated by 3D-CTA, however the Moyamoya collaterals were shown better on MRA. 3D-CTA revealed the site of stenosis of middle cerebral artery in all of our cases, but in general maximum intensity projection (MIP) images can provide more exact information about the degree of stenosis. Five years has passed since the emergence of spiral CT and utilizing of 3D-CTA in clinical applications. With the development of hard and soft ware in the near future, it is possible to delineate more small vessels by 3D-CTA. We predict that 3D-CTA would be widely used for detecting vasculature of the whole body, and may take the place of conventional angiography in many cases. (author)

  5. Angiography-based C-arm CT for the assessment of extrahepatic shunting before radioembolization

    International Nuclear Information System (INIS)

    Heusner, Till Alexander; Hahn, S.; Forsting, M.; Antoch, G.; Hamami, M.E.; Poeppel, T.; Bockisch, A.; Ertle, J.; Hilgard, P.

    2010-01-01

    Purpose: to retrospectively assess the accuracy of angiography-based C-arm CT for the detection of extrahepatic shunting before SIRT. Materials and methods: 30 patients (mean age: 64 ± 12 years) with hypervascularized hepatic tumors underwent hepatic angiography, coil embolization of gastrointestinal collaterals and 99mTc-macroaggregated albumin (MAA) SPECT/CT before SIRT. Before MAA injection via a microcatheter from the intended treatment position, an angiography and angiography-based C-arm CT (XperCT trademark, Philips Healthcare) were acquired. Angiographies and XperCT trademark were performed from 48 microcatheter positions followed by MAA injections and MAA-SPECT/CT. MAA-SPECT/CT served as the reference standard for determining the accuracy of hepatic arteriography and C-arm CT for the detection of extrahepatic shunting. Results: MAA-SPECT/CT revealed extrahepatic shunting in 5 patients (17%). Hepatic arteriography yielded a true negative in 22 (73%), a false negative in 5 (17%), and an unclear result in 3 patients (10%). C-arm CT yielded a true positive in 3 (10%), true negative in 24 (80%), false positive in 1 (3%), and false negative in 2 patients (7%). The specificity and the NPV of hepatic arteriography for the detection of extrahepatic shunting were 88% and 81%, respectively. For C-arm CT the sensitivity, specificity, PPV, NPV, and accuracy for the detection of extrahepatic shunting were 60%, 96%, 75%, 92%, and 90%, respectively. Conclusion: C-arm CT offers additional information to angiography when assessing SIRT patients for extrahepatic shunting. More accurate detection of extrahepatic shunting may optimize the workflow in SIRT preparations by avoiding unnecessary repeat angiographies. (orig.)

  6. Quantitative fluorescence angiography for neurosurgical interventions.

    Science.gov (United States)

    Weichelt, Claudia; Duscha, Philipp; Steinmeier, Ralf; Meyer, Tobias; Kuß, Julia; Cimalla, Peter; Kirsch, Matthias; Sobottka, Stephan B; Koch, Edmund; Schackert, Gabriele; Morgenstern, Ute

    2013-06-01

    Present methods for quantitative measurement of cerebral perfusion during neurosurgical operations require additional technology for measurement, data acquisition, and processing. This study used conventional fluorescence video angiography--as an established method to visualize blood flow in brain vessels--enhanced by a quantifying perfusion software tool. For these purposes, the fluorescence dye indocyanine green is given intravenously, and after activation by a near-infrared light source the fluorescence signal is recorded. Video data are analyzed by software algorithms to allow quantification of the blood flow. Additionally, perfusion is measured intraoperatively by a reference system. Furthermore, comparing reference measurements using a flow phantom were performed to verify the quantitative blood flow results of the software and to validate the software algorithm. Analysis of intraoperative video data provides characteristic biological parameters. These parameters were implemented in the special flow phantom for experimental validation of the developed software algorithms. Furthermore, various factors that influence the determination of perfusion parameters were analyzed by means of mathematical simulation. Comparing patient measurement, phantom experiment, and computer simulation under certain conditions (variable frame rate, vessel diameter, etc.), the results of the software algorithms are within the range of parameter accuracy of the reference methods. Therefore, the software algorithm for calculating cortical perfusion parameters from video data presents a helpful intraoperative tool without complex additional measurement technology.

  7. Estimation of intrathoracic arterial diameter by means of computed tomographic angiography in Hispaniolan Amazon parrots.

    Science.gov (United States)

    Beaufrère, Hugues; Rodriguez, Daniel; Pariaut, Romain; Gaschen Dvm, Lorrie; Schnellbacher, Rodney; Nevarez, Javier G; Tully, Thomas N

    2011-02-01

    To establish a computed tomography (CT)-angiography protocol and measure the diameters of major arteries in parrots. 13 Hispaniolan Amazon parrots (Amazona ventralis). 16-slice CT scanning was used to measure the apparent diameter of the ascending aorta, abdominal aorta, pulmonary arteries, and brachiocephalic trunk. Before scanning, all birds underwent ECG and echocardiographic assessment and were considered free of detectable cardiovascular diseases. Each bird was anesthetized, and a precontrast helical CT scan was performed. Peak aortic enhancement was established with a test bolus technique via dynamic axial CT scan over a predetermined single slice. An additional bolus of contrast medium was then injected, and a helical CT-angiography scan was performed immediately afterward. Arterial diameter measurements were obtained by 2 observers via various windows before and after injection, and intra- and interobserver agreement was assessed. Reference limits were determined for arterial diameter measurements before and after contrast medium administration in pulmonary, mediastinal, and manual angiography windows. Ratios of vertebral body diameter to keel length were also calculated. Intraobserver agreement was high (concordance correlation coefficients ≥ 0.95); interobserver agreement was medium to high (intraclass correlation coefficients ≥ 0.65). CT-angiography was safe and is of potential diagnostic value in parrots. We recommend performing the angiography immediately after IV injection of 3 mL of iohexol/kg. Arterial diameter measurements at the described locations were reliable.

  8. The Efficacy of Iopamidol (Pamiray 370) in Aortic and Extremity CT Angiography

    International Nuclear Information System (INIS)

    Lee, Yoo Jin; Lee, Jong Min; Lee, Hui Joong; Park, Ji Won

    2010-01-01

    To evaluate the clinical safety and radiological feasibility of a domestic iopamidol-based contrast media (Pamiray 370) during an aortic and extremity CT angiography. Between August and December of 2008, 100 patients (M:F=51:49; mean age, 59 years) underwent an aortic and extremity CT angiography using Pamiray 370 based with informed consent. All changes in vital signs, clinical symptoms, and adverse reactions to the contrast media were monitored. Two radiologists assessed the image quality of the CT angiography. A statistical comparison was conducted using an independent t-test and a Mann-Whitney test based on the 100-patient group studied using Optiray 350. The contrast enhancement of the descending aorta in the arterial phase showed a statistically greater efficacy (p<0.001) of Pamiray 370 compared to Optiray 350, which was the routine contrast media for CT angiography for our institute. Adverse reaction signs were evident in 3%(3/100) of the subjects. All of them showed mild and transient reactions such as vomiting (n=2) and coughing (n=1), with no medical treatment required. Contrast media related symptoms including dizziness (n=7), nausea (n=3), headaches (n=2), and injection site pain (n=1), were noted in 12%(12/100). The clinical efficacy of Pamiray 370 was acceptable for the aortic and extremity CT angiography, in terms of clinical safety, tolerance, and image quality

  9. Noninvasive evaluation of cerebral arteriovenous malformations by 4D-CT angiography using 320-detector row CT

    International Nuclear Information System (INIS)

    Tajiri, H.; Jin, L.; Tsukiyama, M.; Suzuki, Y.; Sekine, S.; Shimizu, T.; Ohiwa, T.

    2012-01-01

    Full text: Objective: Four-dimensional computed tomography angiography (4D-CTA) is a new and promising technique in the diagnosis of patients with cerebral arteriovenous malformations (AVMs). The purpose of this retrospective study was to investigate the utility of 4D-CTA using whole-brain 320-detector row CT for assessing cerebral AVMs compared with conventional angiography (CA). Materials and methods: Participants included patients admitted to our institution from November 2010 to March 2012 due to cerebral AVMs who underwent both 4D-CTA and CA within 14 days. The diagnosis of AVM was finally confirmed by CA. Two readers reviewed 4D-CTA and CA under consensus regarding AVM detection rate and each component of the AVM (feeders, nidi, drainers) using a four-point grading scale (excellent=3, good=2, fair=1, poor=0), and the Spetzler-Martin (S-M) grade. Results: During the study period, 11 patients met the inclusion criteria. The average score for feeders, nidi, and drainers was 2.0, 2.3, and 2.5 in 4D-CTA and 2.4, 2.6, and 2.7 in CA, respectively. The average S-M grade score was 2.0 in all patients. There were no statistically significant differences between the two modalities (P<.005). Conclusion: 4D-CTA using 320-detector row CT is a very reliable method and offers diagnostic performance equivalent to CA for detecting and predicting S-M classification of cerebral AVMs.

  10. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot ... I’d like to talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA ...

  11. Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography

    DEFF Research Database (Denmark)

    Fuchs, Andreas; Kühl, J Tobias; Chen, Marcus Y

    2015-01-01

    BACKGROUND: The reader confidence and diagnostic accuracy of coronary CT angiography (CCTA) can be compromised by the presence of calcified plaques and stents causing blooming artifacts. Compared to conventional invasive coronary angiography (ICA), this may cause an overestimation of stenosis....... We defined target segments on CCTAconv as motion-free coronary segments with calcification or stent and low reader confidence. The effect of CCTAsub was assessed. No approval from the ethics committee was required according to Danish law. RESULTS: A total of 76 target segments were identified...

  12. Step-and-shoot prospectively ECG-gated vs. retrospectively ECG-gated with tube current modulation coronary CT angiography using 128-slice MDCT patients with chest pain: diagnostic performance and radiation dose

    International Nuclear Information System (INIS)

    Kim, Jeong Su; Choo, Ki Seok; Jeong, Dong Wook

    2011-01-01

    Background With increasing awareness for radiation exposure, the study of diagnostic accuracy of coronary CT angiography (CCTA) with low radiation dose techniques is mandatory to both radiologist and clinician. Purpose To compare diagnostic performance and effective radiation dose between step-and-shoot prospectively ECG-gated and retrospectively ECG-gated with tube current modulation (TCM) CCTA using 128-slice multidetector computed tomography (MDCT). Material and Methods We retrospectively evaluated 60 patients who underwent CCTA with either of two different low-dose techniques using 128-slice MDCT (23 patients for step-and shoot-prospectively ECG-gated and 37 patients for retrospectively ECG-gated with TCM CCTA) followed by conventional coronary angiography. All coronary arteries and all segments thereof, except anatomical variants or small size (< 1.5 mm) ones, were included in analysis. Results In per-segment analysis, sensitivity, specificity, positive predictive value, and negative predictive value were 91/96%, 95/94%, 75/73%, and 98/99% for step-and-shoot prospectively ECG-gated and retrospectively ECG gated with TCM CCTA, respectively, relative to conventional coronary angiography. Effective radiation dose were 1.75 ± 0.83 mSv, 4.91 ± 1.71 mSv in the step-and-shoot prospectively ECG-gated and retrospectively ECG-gated with TCM CCTA groups, respectively. Conclusion The two low-radiation dose CCTA techniques using 128-slice MDCT yields comparable diagnostic performance for coronary artery disease in symptomatic patients with low heart rates

  13. Using synchrotron radiation angiography with a highly sensitive detector to identify impaired peripheral perfusion in rat pulmonary emphysema

    International Nuclear Information System (INIS)

    Ito, Hiromichi; Matsushita, Shonosuke; Hyodo, Kazuyuki; Sato, Yukio; Sakakibara, Yuzuru

    2013-01-01

    Synchrotron radiation angiography with a HARP detector made it possible to evaluate impaired pulmonary microcirculation in pulmonary emphysema by means of high sensitivity. Owing to limitations in spatial resolution and sensitivity, it is difficult for conventional angiography to detect minute changes of perfusion in diffuse lung diseases, including pulmonary emphysema (PE). However, a high-gain avalanche rushing amorphous photoconductor (HARP) detector can give high sensitivity to synchrotron radiation (SR) angiography. SR angiography with a HARP detector provides high spatial resolution and sensitivity in addition to time resolution owing to its angiographic nature. The purpose of this study was to investigate whether this SR angiography with a HARP detector could evaluate altered microcirculation in PE. Two groups of rats were used: group PE and group C (control). Transvenous SR angiography with a HARP detector was performed and histopathological findings were compared. Peak density of contrast material in peripheral lung was lower in group PE than group C (p < 0.01). The slope of the linear regression line in scattering diagrams was also lower in group PE than C (p < 0.05). The correlation between the slope and extent of PE in histopathology showed significant negative correlation (p < 0.05, r = 0.61). SR angiography with a HARP detector made it possible to identify impaired microcirculation in PE by means of its high spatial resolution and sensitivity

  14. Using synchrotron radiation angiography with a highly sensitive detector to identify impaired peripheral perfusion in rat pulmonary emphysema

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Hiromichi [University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575 (Japan); Matsushita, Shonosuke, E-mail: shomatsu@md.tsukuba.ac.jp [University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575 (Japan); Tsukuba University of Technology, Tsukuba, Ibaraki 305-8521 (Japan); Hyodo, Kazuyuki [High Energy Accelerator Research Organization, KEK, Tsukuba, Ibaraki 305-0801 (Japan); Sato, Yukio; Sakakibara, Yuzuru [University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575 (Japan)

    2013-03-01

    Synchrotron radiation angiography with a HARP detector made it possible to evaluate impaired pulmonary microcirculation in pulmonary emphysema by means of high sensitivity. Owing to limitations in spatial resolution and sensitivity, it is difficult for conventional angiography to detect minute changes of perfusion in diffuse lung diseases, including pulmonary emphysema (PE). However, a high-gain avalanche rushing amorphous photoconductor (HARP) detector can give high sensitivity to synchrotron radiation (SR) angiography. SR angiography with a HARP detector provides high spatial resolution and sensitivity in addition to time resolution owing to its angiographic nature. The purpose of this study was to investigate whether this SR angiography with a HARP detector could evaluate altered microcirculation in PE. Two groups of rats were used: group PE and group C (control). Transvenous SR angiography with a HARP detector was performed and histopathological findings were compared. Peak density of contrast material in peripheral lung was lower in group PE than group C (p < 0.01). The slope of the linear regression line in scattering diagrams was also lower in group PE than C (p < 0.05). The correlation between the slope and extent of PE in histopathology showed significant negative correlation (p < 0.05, r = 0.61). SR angiography with a HARP detector made it possible to identify impaired microcirculation in PE by means of its high spatial resolution and sensitivity.

  15. A new technique for noise reduction at coronary CT angiography with multi-phase data-averaging and non-rigid image registration

    Energy Technology Data Exchange (ETDEWEB)

    Tatsugami, Fuminari; Higaki, Toru; Nakamura, Yuko; Yamagami, Takuji; Date, Shuji; Awai, Kazuo [Hiroshima University, Department of Diagnostic Radiology, Minami-ku, Hiroshima (Japan); Fujioka, Chikako; Kiguchi, Masao [Hiroshima University, Department of Radiology, Minami-ku, Hiroshima (Japan); Kihara, Yasuki [Hiroshima University, Department of Cardiovascular Medicine, Minami-ku, Hiroshima (Japan)

    2015-01-15

    To investigate the feasibility of a newly developed noise reduction technique at coronary CT angiography (CTA) that uses multi-phase data-averaging and non-rigid image registration. Sixty-five patients underwent coronary CTA with prospective ECG-triggering. The range of the phase window was set at 70-80 % of the R-R interval. First, three sets of consecutive volume data at 70 %, 75 % and 80 % of the R-R interval were prepared. Second, we applied non-rigid registration to align the 70 % and 80 % images to the 75 % image. Finally, we performed weighted averaging of the three images and generated a de-noised image. The image noise and contrast-to-noise ratio (CNR) in the proximal coronary arteries between the conventional 75 % and the de-noised images were compared. Two radiologists evaluated the image quality using a 5-point scale (1, poor; 5, excellent). On de-noised images, mean image noise was significantly lower than on conventional 75 % images (18.3 HU ± 2.6 vs. 23.0 HU ± 3.3, P < 0.01) and the CNR was significantly higher (P < 0.01). The mean image quality score for conventional 75 % and de-noised images was 3.9 and 4.4, respectively (P < 0.01). Our method reduces image noise and improves image quality at coronary CTA. (orig.)

  16. Fundus fluorescence Angiography in diagnosing diabetic retinopathy.

    Science.gov (United States)

    Wang, Shuhui; Zuo, Yuqin; Wang, Ning; Tong, Bin

    2017-01-01

    To investigate the manifestation characteristics of fundus fluorescence angiography (FFA) and its values in diagnosing diabetic retinopathy through comparing direct ophthalmoscopy. Two hundred fifty patients (500 eyes) who were suspected as diabetic retinopathy and admitted to the hospital between February 2015 and December 2016 were selected. They underwent direct ophthalmoscopy and FFA. The manifestation characteristics of FFA in the diagnosis of diabetic retinopathy were summarized. The two examination methods were compared. In the diagnosis with direct ophthalmoscopy, 375 eyes out of 500 eyes were diagnosed as diabetic retinopathy (75%); there were 74 eyes at stage I, 88 eyes at stage II, 92 eyes at stage III, 83 eyes of stage IV, 28 eyes of stage V and 10 eyes of stage VI. In the diagnosis with FFA, 465 eyes out of 500 eyes were diagnosed as diabetic retinopathy (93%); there were 94 eyes at stage I, 110 eyes at stage II, 112 at stage III, 92 eyes at stage IV, 41 eyes at stage V and 16 eyes at stage VI. The detection rate of diabetic retinopathy using FFA was significantly higher than that using direct ophthalmoscopy (Pretinopathy (67.96%), 75 eyes had pre-proliferative lesions (16.13%), 149 eyes had proliferative lesions (32.04%), 135 eyes had diabetic maculopathy (29.03%) and 31 eyes had diabetic optic disc lesions (6.67%). The detection rate of diabetic retinopathy using FFA is higher than that using direct ophthalmoscopy. FFA could accurately determine clinical stage. Therefore, it is an important approach in treatment efficacy evaluation and treatment guidance, suggesting a significant application value.

  17. Use of multidetector computed tomography angiography of upper limb circulation in patients undergoing coronary artery bypass grafting surgery

    Directory of Open Access Journals (Sweden)

    Hasan B Altinsoy

    2017-01-01

    Full Text Available Objective: This study aimed to evaluate the bilateral forehand circulation using a 64-channel multidetector computed tomography (MDCT as a noninvasive method to define criteria for an upper extremity arterial anatomy and pathology prior to the use of arterial conduits. Materials and Methods: Fifty-five patients with coronary artery disease who underwent total arterial coronary artery bypass grafting (CABG were randomly selected for this prospective study. MDCT angiography was performed for 110 examinations of forearm and hand arterial anatomy. Prior to MDCT, Allen tests were performed in all patients with a normal result, except four. Thirteen patients had diabetes mellitus (DM, 8 had peripheral artery occlusive disease, and 19 had a history of smoking. Results: All arteries, including axillary, ulnar artery (UA and radial artery (RA, were clearly visualized in all patients. Upper extremity anatomical and pathological results were examined in 16 patients (29.1%. Severely calcified RA and/or UA were found in 6 patients who had a moderate renal failure. Nearly total occlusion of the RA was detected in another two patients. Focal intimal RA calcification was recorded in 1 female and 3 male patients. Ten patients who had severe calcification or intimal sclerosis of the upper extremity arteries had DM. The remaining patients had normal forehand arterial circulation. A persistent median artery with the absence of radial and ulnar arteries and a high bifurcation of RA from the brachial artery was detected as an anatomic variation in seven patients (12.7%. Conclusions: The major advantages of MDCT angiography are its non-invasiveness and the ability to detect calcific subadventitial plaques, which are difficult to diagnose using conventional angiography. MDCT may be used as a safe and non-invasive method to assess RA and UA prior to harvesting the upper limb artery. Preoperative imaging of forehand arteries is a means to avoid unnecessary forearm

  18. Digital subtraction angiography of the heart and lungs

    International Nuclear Information System (INIS)

    Moodie, D.S.; Yiannikas, J.

    1986-01-01

    This book contains 12 chapters. Some of the chapter titles are: Physical Principles of Cardiac Digital Subtraction Angiography, The Use of Intravenous Digital Subtraction Angiography in Evaluating Patients with Complex Congenital Heart Disease, Exercise Intravenous Digital Subtraction Angiograpny, Cardiomyopathic and Cardiac Neoplastic Disease, Digital Subtraction Angiography in the Catheterization Laboratory, and Cardiac Digital Subtraction Angiography - Future Directions

  19. Artifacts in MR angiography of the intracranial vessels using the 3D TOF and 3D PC techniques

    International Nuclear Information System (INIS)

    Park, Dong Woo; Lee, Seung Ro; Hahm, Chang Kok; Kim, Yong Soo; Park, Choong Ki

    1997-01-01

    To classify artifacts and to assess their frequency in magnetic resonance angiography of intracranial vessels using three- dimensional time-of-flight and phase-contrast techniques. One hundred and eleven patients with suspected cerebrovascular disease were imaged on a 1.5T superconducting magnetic resonance machine employing three- dimensional time-of-flight and phase-contrast magnetic resonance angiographic techniques. We retrospectively reviewed the artifacts in three- dimensional time-of-flight and phase-contrast magnetic resonance angiography of the intracranial circulatory system, comparing them with routine spin-echo magnetic resonance images and magnetic resonance angiography source images, and partially with conventional angiography. Artifacts in magnetic resonance angiography were classified as flow-related, and flow-unrealted, by patient, hardware, magnetic resonance angiography acquisition and postprocessing techniques. Type and frequency of flow-related artifacts included saturation artifact (100%), dephasing artifact (100%), phase-encoding ghost artifact (97%), turbulence artifact (14%) and flow displacement artifact (5%) on three- dimensional time-of-flight and phase-contrast magnetic resonance angiography, and phase aliasing artifact (2%) on three-dimensional phase-contrast magnetic resonance angiography. Type and frequency of flow-unrelated artifacts included stair-step artifact (100%) by three- dimensional reconstruction process, magnetic susceptibility artifact by carotid canal (69%) and metal (4%), maximum intensity projection artifact (30%) by maximum intensity projection algorithm, and motion artifact by respiration (20%) and voluntary movement (8%); these were seen on both time-of-flight and phase-contrast magnetic resonance angiography. Paramagnetic substance artifact by fat and paranasal sinus mucosa (100%), hematoma (14%) and gadolinium (5%) were seen on time-of-flight magnetic resonance angiography. In three- dimensional time-of-flight and

  20. Neuronavigation for arteriovenous malformation surgery by intraoperative three-dimensional ultrasound angiography.

    Science.gov (United States)

    Mathiesen, Tiit; Peredo, Inti; Edner, Göran; Kihlström, Lars; Svensson, Mikael; Ulfarsson, Elfar; Andersson, Tommy

    2007-04-01

    Neuronavigational devices have traditionally used preoperative imaging with limited possibilities for adjustment to brain shift and intraoperative manipulation of the surgical lesions. We have used an intraoperative imaging and navigation system that uses navigation on intraoperatively acquired three-dimensional ultrasound data, as well as preoperatively acquired magnetic resonance imaging scans and magnetic resonance angiograms. The usefulness of this system for arteriovenous malformation (AVM) surgery was evaluated prospectively. Nine consecutive patients with Spetzler Grade 1 (n = 3), 2 (n = 3), 3(n = 2) or 4 (n = 1) AVMs underwent operation using this intraoperative imaging and navigation system. The system provides real-time rendering of three-dimensional angiographic data and can visualize such projections in a stereoscopic (virtual reality) manner using special glasses. The experiences with this technology were analyzed and the outcomes assessed. Angiographic reconstructions of three-dimensional images were obtained before and after resection. Conventional navigation on the basis of preoperative magnetic resonance angiography was helpful to secure positioning of the bone flap; stereoscopic visualization of the same data represented a powerful means to construct a mental three-dimensional picture of the extent of the AVM and the feeder anatomy even before skin incision. Intraoperative ultrasound corresponded well to the intraoperative findings and allowed confirmation of feeding vessels in surrounding gyri and rapid identification of the perinidal dissection planes, regardless of brain shift. The latter feature was particularly helpful because the intraoperative navigational identification of surgical planes leads to minimal exploration into the nidus or dissection at a greater distance from the malformation. Application of the system was thought to increase surgical confidence. In two patients, postresection ultrasound prompted additional nidus removal

  1. Protocols and Results of Resident Neurosurgeon's Transfemoral Catheter Angiography Training Supervised by Neuroendovascular Specialists

    Science.gov (United States)

    Shin, Dong-Seong; Yeo, Dong-Kyu; Hwang, Sun-Chul; Park, Sukh-Que

    2013-01-01

    Objective Transfemoral catheter angiography (TFCA) is a basic procedure in neurovascular surgery with increasing importance in surgical and non-invasive treatments. Unfortunately, resident neurosurgeons have relatively few opportunities to perform TFCA in most institutions. We report a method developed in our hospital for training resident neurosurgeons to perform TFCA and evaluate the efficacy of this training. Methods From May 2011 to September 2011, a total of 112 consecutive patients underwent TFCA by one resident neurosurgeon supervised by two neuroendovascular specialists. Patients who underwent elective diagnostic procedures were included in this study. Patients who underwent endovascular treatment were excluded. Demographic data, indications for TFCA, side of approach, number of selected arteries, and complications were analyzed. Results This study included 64 males and 48 females with a mean age of 51.6 (12-81) years. All procedures were performed in the angiography suite. Common indications for procedures were as follows: stroke-induced symptoms in 61 patients (54.5%), Moyamoya disease and arteriovenous malformation in 13 patients (11.6%), and unruptured intracranial aneurysm in eight patients (7.1%). Right and left femoral puncture was performed in 98.2% and 1.8% of patients, respectively. A total of 465 selective angiographies were performed without complications. Angiographic examination was performed on 4.15 vessels per patient. Conclusion TFCA can be performed safely by resident neurosurgeons based on anatomical study and a meticulous protocol under the careful supervision of neuroendovascular specialists. PMID:24175020

  2. [Nursing care in fluorescein angiography].

    Science.gov (United States)

    Santos-Blanco, Feliciano

    2008-01-01

    Fluoresceinic angiography of the ocular fundus is a diagnostic technique to study retinal and choroidal circulation. This technique consists of parenteral administration of 500 mg of sodium fluorescein 10% and photographing the fluorescence in the eye vessels. Although this substance is fairly safe, it may also produce mild, moderate or severe local and/or general adverse reactions. The nursing process is routinely used in hospital units but not always in outpatient clinics, even through the use of invasive procedures with intravenous medication administration is common. Therefore, nurses, as those reponsible for intravenous administration, should use the nursing process to guarantee the quality of care required by the patient. To do this, we describe an individualized care plan based on evaluation by Marjorie Gordon's functional health patterns, NANDA's nursing diagnoses Taxonomy II, Nursing Outcomes Classification (NOC), Nursing Interventions Classifications (NIC) and potential complications of the procedure.

  3. Angiography of primary bone tumors

    International Nuclear Information System (INIS)

    Keyl, W.; Kunkel, B.

    1982-01-01

    To determine the type of a tumour by means of angiography is problematical. Considering that tumour-simulating lesions (myositis ossificans, modular synoritis) can also show pathological blood vessel formations and AV-shunts the interpretation of vessel-architectonic criteria must be done very carefully. The finding of some individual signs of malignancy does not justify the diagnosis of ''malignant tumour''. Only the ''anarchic vessel picture'' (Freyschmidt) with changing caliber, corkscrew vessels, interrupted vessels, unregular tumour colouring, arteria-venous shunts and possibly also tumour invasion into vessels makes a malignant process very likely. The absence of these criteria, however, does not exclude malignancy. Non-vascularised malignant tumours can only lead to a displacement of vessels without an angiographic proof of the tumour itself. (orig./APR) [de

  4. Coronary MR angiography: current status

    International Nuclear Information System (INIS)

    Danias, P.G.; Manning, W.J.

    2000-01-01

    Since first described in the early 1990s, coronary magnetic resonance angiography (MRA) has evolved as a promising noninvasive modality for imaging of the coronary arteries and evaluation of coronary artery disease. Despite technical limitations, coronary MRA has established value for imaging of anomalous coronary arteries and assessment of bypass graft patency. Current research focuses on the development of optimal respiratory compensation strategies, improved spatial and temporal resolution and faster acquisition of image data. The accurate detection of stenoses and assessment of the severity of coronary atherosclerosis is presently being evaluated with large multi-center studies. With further technique enhancements and more clinical experience, coronary MRA is likely to become the dominant noninvasive modality in clinical cardiology. (orig.) [de

  5. Evaluation of three-dimensional contrast-enhanced MR angiography in pediatric body vascular lesions

    International Nuclear Information System (INIS)

    Tanaka, Yasunori; Katayama, Hiroshi; Yamamoto, Kazuhiro; Shimizu, Tadafumi; Narabayashi, Isamu

    1998-01-01

    Evaluation of three-dimensional contrast-enhanced MR angiography in the pediatric body vascular lesions. This study examined the usefulness of three-dimensional gadolinium-enhanced magnetic resonance angiography (3D-enhanced MRA) for pediatric body vascular lesions. Fifteen 3D-enhanced MRAs were performed on fourteen pediatric patients aged from one month to fifteen years, using a 3D fast SPGR sequence. Maximum intensity projection (MIP) and multiplanar reconstruction (MPR) images were obtained from the imaging data in all cases, and eleven MIP images were obtained after subtraction of precontrast-enhanced imaging data from postcontrast-enhanced imaging data. In six cases, MIP and MPR images were correlated with cine or digital subtraction angiographies, and the eleven subtracted MIP images were compared with those before subtraction. Clinical usefulness was demonstrated in fourteen (93%) of the fifteen cases, and in seven (64%) of the eleven cases in which subtraction was performed, image quality was improved. In comparison with cine or digital subtraction angiographies, however, only one (17%) MRA was superior. It was considered that 3D-enhanced MRA was useful for pediatric body vascular lesions because of advantages such as lower invasiveness compared with that of conventional angiography, absence of radiation exposure, safety of contrast media, easy availability of MPR images, and short scanning time. In conclusion, if a pediatric body vascular lesion is suspected, 3D-enhanced MRA should be performed before conventional angiography. It also seems that 3D-enhanced MRA may be useful for follow-up. (author)

  6. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  7. Digital subtraction angiography for breast cancer

    International Nuclear Information System (INIS)

    Tsurumi, Kiyohiko; Okuyama, Nobuo

    1987-01-01

    We performed digital subtraction angiography (DSA) on 42 patients with breast diseases to investigate its efficiency. As a result we came to the following conclusions: 1. The sensitivity was well evaluated in intraarterial digital subtraction angiography (IA-DSA) of breast. 2. IA-DSA could diagnose difficult cases like cancer which had undergone augmentation mammoplasty, or like Paget's disease and others. 3. DSA was a safe examination method. 4. The sensitivity of IA-DSA of breast cancer is superior to intravenous digital subtraction angiography (IV-DSA). (author)

  8. MR angiography in the diagnosis of tumors in the head and neck

    International Nuclear Information System (INIS)

    Vogl, T.J.; Balzer, J.O.; Juergens, M.; Lissner, J.; Grevers, G.

    1992-01-01

    40 normal individuals and 153 patients with lesions in the head and neck were examined by conventional imaging methods and by means of MR angiography (1.5 Tesla Magnetome). The problems to be solved concerned the ralationship between tumors and vessels and vascular anomalies and abnormalities at the skull base (56 cases), the facial skeleton (62 cases) and the neck (35 cases). Digital subtraction angiography was performed in 54 patients and the findings corelated with MR angiography. Optimal results were obtained by using a FISP 3D sequence; in this way arterial structures could be rendered reproducibly down to a diameter of 2 mm. The venous system in the head and neck was best shown by a FLASH 2D sequence. Correlation with arterial DSA showed high accuracy of MR angiography (91%) concerning displacement of vessels, the topography and the recognition of vascular occlusions. Our results indicate that MR angiography is a rapid and reliable procedure for evaluating the arterial and venous changes due to tumors in the head and neck region. (orig.) [de

  9. Comparison of Myocardial Perfusion Scintigraphy and Coronary Angiography Results

    Directory of Open Access Journals (Sweden)

    Umut Elboga

    2017-05-01

    Full Text Available Aim: Coronary artery disease (CAD is one of the most frequent causes of mortality and morbidity worldwide. Coronary angiography is the gold standard for the anatomical diagnosis of coronary artery stenosis. Myocardial Perfusion Scintigraphy (MPS is a non-invasive imaging modality used for the diagnosis of CAD. In this study, we aimed to compare the findings of MPS and coronary angiogram. Material and Method: Eighty-one patients (37 males, 44 females; mean age 55 ± 10.95 years with angina and detected perfusion defects on MPS were included in this study. All of the patients underwent coronary angiogram. A narrowing %u2265 50% was considered pathological on the coronary angiography. Results: Findings of the coronary angiogram and MPS were compared and found consistent in 51 (63% patients. A coronary narrowing < 50% was detected by coronary angiogram in 4 (5% of the remaining patients. Coronary angiogram was found to be normal in the remaining 26 patients (32% and these patients were evaluated as cardiac syndrome X (CSX known as microvascular angina (MA. Discussion: The findings showed that MPS is superior to coronary angiogram in the early diagnosis of myocardial perfusion disorders at the microvascular level. Therefore, we concluded that MPS should be the primary diagnostic tool to begin treatment before an anatomically large narrowing occurs in the coronaries.

  10. Fluorescein angiography and retinal vascular development in premature infants.

    Science.gov (United States)

    Purcaro, Velia; Velia, Purcaro; Baldascino, Antonio; Antonio, Baldascino; Papacci, Patrizia; Patrizia, Papacci; Giannantonio, Carmen; Carmen, Giannantonio; Molisso, Anna; Anna, Molisso; Molle, Fernando; Fernando, Molle; Lepore, Domenico; Domenico, Lepore; Romagnoli, Costantino; Costantino, Romagnoli

    2012-10-01

    To investigate the role of fluorescein angiography (FA) in the management of retinopathy of prematurity (ROP) in preterm newborns. An observational case series of 13 extremely low birth weight infants. From September 2009 to March 2010, 13 newborn infants with a gestational age <29 weeks end/or birth weight <1000 g underwent serial fluorescein angiography with RetCam (Clarity, Pleasanton, CA) every 2 weeks. The fluorescein angiograms were examined to optimize the timing of diagnosis of ROP and to investigate development of retinal and choroidal vascularization. There were no side effects related to FA. Variable features of retinal and choroidal circulation in preterm infants with a high risk of developing ROP were noted. FA allows vessels branching at the junction between vascular and avascular retina (V-Av junction) to be viewed easily and shows the ROP findings that sometimes cannot be seen by indirect ophthalmoscopy. Dye leakage is the most significant sign of progression to severe ROP or the need for surgery in newborn babies with ROP. RetCam-assisted intravenous FA is safe and allows a more objective assessment of the ROP stage and zone.

  11. Liver hydatid cyst ruptured into the thorax: CT angiography findings of a case

    International Nuclear Information System (INIS)

    Kara, K.; Ors, F.; Bozlar, U.; Tasar, M.

    2012-01-01

    Full text: Introduction: Intrathoracic rupture of hepatic hydatid cyst is a rare but severe condition causing a spectrum of lesions to the pleura, lung parenchyma, and bronchi. Pulmonary complications result from the proximity of hydatid cysts in the liver and the diaphragm. Objectives and tasks: In this report we aimed to present computed tomography (CT) angiography findings of a case with liver hydatid cyst ruptured into the thorax. The patient underwent CT angiography examination with suspicion of pulmonary embolism. Materials and methods: A 71-year-old female patient admitted to our emergency department with complaints of severe and persistent cough. Basal region of the right hemithorax could not get breath sounds on physical examination. Chest radiography revealed the presence of consolidation-effusion. The patient was treated with antibiotherapy for pneumonia and parapneumonic effusion. Because of the clinical symptoms and chest radiograph findings persisted the patient underwent CT angiography examination with suspicion of pulmonary embolism. Results: On CT angiography images pulmonary artery and its branches were normal. There were subtotal collapse in the right middle and lower lung lobes and complicated cystic lesion that has air densities in the basal interlobar space. Another thick walled complicated cystic lesion with multiple septations and air densities was detected in the right posterior liver lobe. The right hemidiaphragm was interrupted and the right liver lobe partially herniated into the thorax cavity. Serologic tests were positive for Echinococcus granulosus and there were prior therapy history for liver cyst hydatid. The diagnostic aspiration findings were consistent with hydatid cyst lesion. Conclusion: In patients with hepatic hydatid cyst associated with persistent and severe cough, thoracic rupture of the cyst should be considered in differential diagnosis. CT angiography is fast, non-invasive and effective method in the detection of

  12. Fluorescent Angiography Used to Evaluate the Perfusion Status of Anastomosis in Laparoscopic Anterior Resection.

    Science.gov (United States)

    Koh, Frederick H; Tan, Ker-Kan

    2016-12-01

    Anastomotic leakage after gastrointestinal surgery is associated with significant morbidity and mortality.1 Insufficient vascular supply is one cause.2 Recent reports of using intraoperative indocyanine green (ICG) fluorescent angiography to evaluate whether perfusion of the anastomosis is adequate has yielded positive outcomes.3 - 6 The authors describe their use of ICG-enhanced fluorescence angiography in a laparoscopic anterior resection. The patient was an 80-year-old with an upper rectal adenocarcinoma and significant cardiovascular risk factors. Fluorescence angiography with 0.4 mg/kg of ICG was administered intravenously just before the colorectal anastomosis was fashioned. A near-infrared (NIR) laparoscopic camera (KARLSTORZ, GmbH & Co. KG, Tuttlingen, Germany) was used to inspect the anastomosis. For this video, 0.4 mg/kg of ICG also was injected after ligation of the inferior mesenteric artery to demonstrate the appearance of a poorly perfused sigmoid bowel. Just before the staple was fired to fashion the colorectal anastomosis, an intravenous bolus of ICG was administered. Within seconds, vessels on both ends of the anastomosis turned fluorescent blue, indicating adequacy of perfusion. The use of ICG did not significantly lengthen the operative time (285 min) because its effect appeared within seconds after its administration. The patient recovered well and was discharged on postoperative day 5. Another four patients who also underwent intraoperative fluorescent angiography for left-sided colorectal lesions did not experience anastomotic leakage. The study showed that ICG fluorescent angiography is a simple and quick intraoperative tool for evaluating the perfusion of the anastomosis. The authors' experience with ICG fluorescent angiography has shown promising results, with a 0 % anastomotic leak rate.

  13. En-face optical coherence tomography angiography of neovascularization elsewhere in hemicentral retinal vein occlusion

    Directory of Open Access Journals (Sweden)

    Sogawa K

    2015-10-01

    Full Text Available Kenji Sogawa, Taiji Nagaoka, Akihiro Ishibazawa, Atsushi Takahashi, Tomofumi Tani, Akitoshi Yoshida Department of Ophthalmology, Asahikawa Medical University, Asahikawa, Japan Purpose: To evaluate how the growth of neovascularization elsewhere (NVE was delineated in an eye with hemicentral retinal vein occlusion (CRVO using optical coherence tomography (OCT angiography. Patients and methods: We examined a 64-year-old man diagnosed with hemi-CRVO. The area around the occluded vein was scanned using a spectral-domain OCT device (RTVue XR Avanti. Blood flow was detected using the split-spectrum amplitude-decorrelation angiography (SSADA algorithm. Color fundus photography, fluorescein angiography (FA, and OCT angiography examinations were performed at the first visit and at 3 and 6 months postpresentation. Results: At the first visit, FA revealed delayed retinal venous filling and extensive areas of capillary nonperfusion. The patient underwent a trial of intravitreal ranibizumab injection (0.5 mg/0.05 mL for the treatment of macular edema. At 3 months postpresentation, there was no NVE around the occluded vein in the en-face SSADA image, but at 6 months, NVE appeared on the occluded veins. The en-face SSADA image showed the NVE structure in the fibrovascular membrane on the occluded vein more clearly than FA images. Conclusion: OCT angiography clearly visualized the sprouting of NVE in an eye with hemi-CRVO. New findings of the vascular structure of NVE in hemi-CRVO were revealed using the en-face SSADA algorithm. Keywords: OCT angiography, hemi-CRVO, NVE

  14. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Disorders Video: The Basketball Game: An MRI Story Radiology and You Sponsored by Image/Video Gallery Your ... Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot org Hello, I’m Dr. Elliot ...

  15. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Angiography (MRA) Transcript Welcome to Radiology Info dot org Hello, I’m Dr. Elliot Fishman, a radiologist ... question you might have, visit Radiology Info dot org. Thank you for your time and for your ...

  16. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive test ... of the major blood vessels throughout your body. It may be performed with or without contrast material ...

  17. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... An MRI Story Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography ( ... posted: How to Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI ...

  18. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... mild sedative prior to the examination. For more information about Magnetic Resonance Angiography of MRA or any ... Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  19. Infrared-laser-based fundus angiography

    Science.gov (United States)

    Klingbeil, Ulrich; Canter, Joseph M.; Lesiecki, Michael L.; Reichel, Elias

    1994-06-01

    Infrared fundus angiography, using the fluorescent dye indocyanine green (ICG), has shown great potential in delineating choroidal neovascularization (CNV) otherwise not detectable. A digital retinal imaging system containing a diode laser for illumination has been developed and optimized to perform high sensitivity ICG angiography. The system requires less power and generates less pseudo-fluorescence background than nonlaser devices. During clinical evaluation at three retinal centers more than 200 patients, the majority of which had age-related macular degeneration, were analyzed. Laser based ICG angiography was successful in outlining many of the ill-defined or obscure CNV as defined by fluorescein angiography. The procedure was not as successful with classic CNV. ICG angiograms were used to prepare and guide laser treatment.

  20. Application of OCT angiography in ophthalmology

    Directory of Open Access Journals (Sweden)

    Ai-Ping Yang

    2017-11-01

    Full Text Available Optical coherence tomography angiography(OCTAis a new technology of angiography in recent years. In addition to the advantages of traditional OCT, it can observe blood flow in different retinal and choroidal segmentation slab. By using the pseudo-color, abnormal vascular structure can be distinguished from normal vascular structure of the retina. Dye injection is not needed with OCTA, which is different from fundus fluorescein angiography(FFAand indocyanine green angiography(ICGA. OCTA provides more and more accurate blood flow information. However, like other biometric technology, OCTA has its limitations and shortcomings. This review will analyze and summarize the operating principle of OCTA, its application in ophthalmology, as well as its advantages and limitations.

  1. MR angiography and the preoperative evaluation of renal arteries

    International Nuclear Information System (INIS)

    Nakahara, Kimitoshi; Yokoyama, Hiroshi; Tsuji, Yuji

    2001-01-01

    To determine the accuracy of gadolinium-enhanced, three-dimensional, magnetic resonance angiography (3D-MRA) in the visualization of the arterial anatomy of the kidney, we compared preoperative 3D-MRA results with surgical findings in 37 patients who underwent renal surgery. 3D-MRA findings were confirmed surgically in 30 of these patients (81%). However, 4 of 7 accessory renal arteries were missed by this imaging technique. Furthermore, 3D-MRA failed to visualize renal arteries in all of the three atrophic kidneys. 3D-MRA is a safe and reliable procedure for the preoperative evaluation of renal arteries. However, the depiction of smaller renal arteries, such as accessory and atrophic arteries, is less accurate. (author)

  2. 320-detector row CT coronary angiography in patients with arrhythmia

    International Nuclear Information System (INIS)

    Lu Li; Zhang Zhaoqi; Xu Lei; Yang Lin

    2011-01-01

    Objective: To evaluate the feasibility of CT coronary angiography (CTCA) in patients with arrhythmia using 320-detector row CT. Methods: Thirty-one patients with persistent atrial fibrillation and 8 patients with premature ventricular contraction were enrolled in this study. All patients underwent 320- detector row CTCA. CT image quality was evaluated with 4-point grading scale by two radiologists. Inter- observer agreement was evaluated by Kappa statistics. The radiation dose was calculated. Results: In total 510 coronary segments, 496 (97.2%) segments met diagnostic standard. The mean effective dose was (12.7±4.8) mSv in this study. There was a good agreement in image quality scoring between the two reviewers (Kappa = 0.72). Conclusion: 320-detector row CTCA is feasible in patients with atrial fibrillation and premature ventricular contraction. Arrhythmia may not be considered as a contraindication to CTCA. (authors)

  3. ECG-gating in non-cardiac digital subtraction angiography

    International Nuclear Information System (INIS)

    Gattoni, F.; Baldini, V.; Cairo, F.

    1987-01-01

    This paper reports the results of the ECG-gating in non-cardiac digital subtraction angiography (DSA). One hundred and fifteen patients underwent DSA (126 examinations); ECG-gating was applied in 66/126 examinations: images recorded at 70% of R wave were subtracted. Artifacts produced by vascular movements were evaluated in all patients: only 40 examinations, carried out whithout ECG-gating, showed vascular artifacts. The major advantage of the ECG-gated DSA is the more efficent subtraction because of the better images superimposition: therefore, ECG-gating can be clinically helpful. On the contrary, it could be a problem in arrhytmic or bradycardic patients. ECG-gating is helpful in DSA imaging of the thoracic and abdominal aorta and of the cervical and renal arteries. In the examinations of peripheral vessels of the limbs it is not so efficent as in the trunk or in the neck

  4. MR angiography and the preoperative evaluation of renal arteries

    Energy Technology Data Exchange (ETDEWEB)

    Nakahara, Kimitoshi; Yokoyama, Hiroshi; Tsuji, Yuji [Fukuoka Univ. (Japan). School of Medicine

    2001-04-01

    To determine the accuracy of gadolinium-enhanced, three-dimensional, magnetic resonance angiography (3D-MRA) in the visualization of the arterial anatomy of the kidney, we compared preoperative 3D-MRA results with surgical findings in 37 patients who underwent renal surgery. 3D-MRA findings were confirmed surgically in 30 of these patients (81%). However, 4 of 7 accessory renal arteries were missed by this imaging technique. Furthermore, 3D-MRA failed to visualize renal arteries in all of the three atrophic kidneys. 3D-MRA is a safe and reliable procedure for the preoperative evaluation of renal arteries. However, the depiction of smaller renal arteries, such as accessory and atrophic arteries, is less accurate. (author)

  5. Digital subtraction CT angiography for the detection of posterior inferior cerebellar artery aneurysms: comparison with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Guo Zhong; Luo, Song; Zhou, Chang Sheng; Zhang, Long Jiang; Lu, Guang Ming [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China)

    2017-09-15

    To evaluate the diagnostic accuracy of digital subtraction CT angiography (DS-CTA) in detecting posterior inferior cerebellar artery (PICA) aneurysms with digital subtraction angiography (DSA) as reference standard. A total of 115 patients, including 56 patients diagnosed with PICA aneurysms by CTA or DSA and 59 non-PICA-aneurysm patients were included in this retrospective study. All patients underwent DS-CTA and DSA. The site of PICA aneurysms and the pattern of haemorrhage were analysed. Sensitivity and specificity of DS-CTA without and with combining haemorrhage pattern in diagnosing PICA aneurysms were evaluated on a per patient and per aneurysm basis with DSA. Of 115 patients, 56 patients (48.7%) had 61 PICA aneurysms (size range, 1.1-13.5 mm; mean size, 4.9 ± 2.8 mm) on DSA. The sensitivity and specificity in depicting PICA aneurysms were 89.3% and 96.6% on a per patient basis and 90.2% and 93.4% on a per aneurysm basis, while the corresponding values were 94.6% and 96.6% on a per patient basis and 95.1% and 93.4% on a per aneurysm basis when combining with haemorrhage site. DS-CTA has a high sensitivity and specificity in detecting PICA aneurysms compared with DSA. It may be helpful for clinical diagnosis of PICA aneurysms to combine with haemorrhage sites. (orig.)

  6. Non-contrast 3D black blood MRI for abdominal aortic aneurysm surveillance: comparison with CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Chengcheng; Leach, Joseph R.; Hope, Michael D. [University of California San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Tian, Bing; Liu, Qi; Lu, Jianping; Chen, Luguang [Changhai Hospital, Department of Radiology, Shanghai (China); Saloner, David [University of California San Francisco, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Radiology Service, VA Medical Center, San Francisco, CA (United States)

    2017-05-15

    Management of abdominal aortic aneurysms (AAAs) is based on diameter. CT angiography (CTA) is commonly used, but requires radiation and iodinated contrast. Non-contrast MRI is an appealing alternative that may allow better characterization of intraluminal thrombus (ILT). This study aims to 1) validate non-contrast MRI for measuring AAA diameter, and 2) to assess ILT with CTA and MRI. 28 patients with AAAs (diameter 50.7 ± 12.3 mm) underwent CTA and non-contrast MRI. MRI was acquired at 3 T using 1) a conventional 3D gradient echo (GRE) sequence and 2) a 3D T{sub 1}-weighted black blood fast-spin-echo sequence. Two radiologists independently measured the AAA diameter. The ratio of signal of ILT and adjacent psoas muscle (ILT{sub r} = signal{sub ILT}/signal{sub Muscle}) was quantified. Strong agreement between CTA and non-contrast MRI was shown for AAA diameter (intra-class coefficient > 0.99). Both approaches had excellent inter-observer reproducibility (ICC > 0.99). ILT appeared homogenous on CTA, whereas MRI revealed compositional variations. Patients with AAAs ≥5.5 cm and <5.5 cm had a variety of distributions of old/fresh ILT types. Non-contrast 3D black blood MRI provides accurate and reproducible AAA diameter measurements as validated by CTA. It also provides unique information about ILT composition, which may be linked with elevated risk for disease progression. (orig.)

  7. Impact of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in multislice Computed Tomography coronary angiography

    International Nuclear Information System (INIS)

    Cademartiri, Filippo; Mollet, Nico R.; Kriestin, Gabriel P.; Runza, Giuseppe; Bartolotta, Tommaso Vincenzo; Galia, Massimo; Midiri, Massimo; Belgrano, Manuel; Pozzi Mucelli, Roberto

    2005-01-01

    Purpose. To assess the effect of intravascular enhancement, heart rate, and calcium score on diagnostic accuracy in the detection of significant coronary artery stenosis using 16-row multislice computed tomography (MSCT). Materials and methods. One hundred patients (88 males; 59±11 years) with suspected coronary artery disease who had undergone conventional coronary angiography (CA) and MSCT-CA were retrospectively enrolled for the study. Patients underwent a MSCT-CA, with the following protocol: collimation 16x0.75 mm, gantry rotation time 420 ms, feed/rotation 2.8 mm, kV 120, mAs 400-500. The protocol for contrast material administration was 100 ml of Iodixanol 320 mgI/nl at 4 ml/s and the scan delay was defined with a bolus tracking technique. In all patients vascular enhancement was measured in the aortic root, and the left and the right coronary arteries. The average enhancement was used to divide the population in two groups of 50 patients each, one with lower enhancement (Low), and one with higher enhancement (High). In the two groups diagnostic accuracy (per coronary segment) for the detection of significant stenosis (≥50% lumen reduction) was evaluated in vessels ≥2mm in diameter using quantitative CA as the reference standard. The differences in diagnostic accuracy were compared with a Chi-square test and a p [it

  8. Real-time fusion of coronary CT angiography with X-ray fluoroscopy during chronic total occlusion PCI

    Energy Technology Data Exchange (ETDEWEB)

    Ghoshhajra, Brian B.; Takx, Richard A.P. [Harvard Medical School, Cardiac MR PET CT Program, Massachusetts General Hospital, Department of Radiology and Division of Cardiology, Boston, MA (United States); Stone, Luke L.; Yeh, Robert W.; Jaffer, Farouc A. [Harvard Medical School, Cardiac Cathetrization Laboratory, Cardiology Division, Massachusetts General Hospital, Boston, MA (United States); Girard, Erin E. [Siemens Healthcare, Princeton, NJ (United States); Brilakis, Emmanouil S. [Cardiology Division, Dallas VA Medical Center and UT Southwestern Medical Center, Dallas, TX (United States); Lombardi, William L. [University of Washington, Cardiology Division, Seattle, WA (United States)

    2017-06-15

    The purpose of this study was to demonstrate the feasibility of real-time fusion of coronary computed tomography angiography (CTA) centreline and arterial wall calcification with X-ray fluoroscopy during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). Patients undergoing CTO PCI were prospectively enrolled. Pre-procedural CT scans were integrated with conventional coronary fluoroscopy using prototype software. We enrolled 24 patients who underwent CTO PCI using the prototype CT fusion software, and 24 consecutive CTO PCI patients without CT guidance served as a control group. Mean age was 66 ± 11 years, and 43/48 patients were men. Real-time CTA fusion during CTO PCI provided additional information regarding coronary arterial calcification and tortuosity that generated new insights into antegrade wiring, antegrade dissection/reentry, and retrograde wiring during CTO PCI. Overall CTO success rates and procedural outcomes remained similar between the two groups, despite a trend toward higher complexity in the fusion CTA group. This study demonstrates that real-time automated co-registration of coronary CTA centreline and calcification onto live fluoroscopic images is feasible and provides new insights into CTO PCI, and in particular, antegrade dissection reentry-based CTO PCI. (orig.)

  9. Non-contrast 3D black blood MRI for abdominal aortic aneurysm surveillance: comparison with CT angiography

    International Nuclear Information System (INIS)

    Zhu, Chengcheng; Leach, Joseph R.; Hope, Michael D.; Tian, Bing; Liu, Qi; Lu, Jianping; Chen, Luguang; Saloner, David

    2017-01-01

    Management of abdominal aortic aneurysms (AAAs) is based on diameter. CT angiography (CTA) is commonly used, but requires radiation and iodinated contrast. Non-contrast MRI is an appealing alternative that may allow better characterization of intraluminal thrombus (ILT). This study aims to 1) validate non-contrast MRI for measuring AAA diameter, and 2) to assess ILT with CTA and MRI. 28 patients with AAAs (diameter 50.7 ± 12.3 mm) underwent CTA and non-contrast MRI. MRI was acquired at 3 T using 1) a conventional 3D gradient echo (GRE) sequence and 2) a 3D T_1-weighted black blood fast-spin-echo sequence. Two radiologists independently measured the AAA diameter. The ratio of signal of ILT and adjacent psoas muscle (ILT_r = signal_I_L_T/signal_M_u_s_c_l_e) was quantified. Strong agreement between CTA and non-contrast MRI was shown for AAA diameter (intra-class coefficient > 0.99). Both approaches had excellent inter-observer reproducibility (ICC > 0.99). ILT appeared homogenous on CTA, whereas MRI revealed compositional variations. Patients with AAAs ≥5.5 cm and <5.5 cm had a variety of distributions of old/fresh ILT types. Non-contrast 3D black blood MRI provides accurate and reproducible AAA diameter measurements as validated by CTA. It also provides unique information about ILT composition, which may be linked with elevated risk for disease progression. (orig.)

  10. Real-time fusion of coronary CT angiography with x-ray fluoroscopy during chronic total occlusion PCI.

    Science.gov (United States)

    Ghoshhajra, Brian B; Takx, Richard A P; Stone, Luke L; Girard, Erin E; Brilakis, Emmanouil S; Lombardi, William L; Yeh, Robert W; Jaffer, Farouc A

    2017-06-01

    The purpose of this study was to demonstrate the feasibility of real-time fusion of coronary computed tomography angiography (CTA) centreline and arterial wall calcification with x-ray fluoroscopy during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). Patients undergoing CTO PCI were prospectively enrolled. Pre-procedural CT scans were integrated with conventional coronary fluoroscopy using prototype software. We enrolled 24 patients who underwent CTO PCI using the prototype CT fusion software, and 24 consecutive CTO PCI patients without CT guidance served as a control group. Mean age was 66 ± 11 years, and 43/48 patients were men. Real-time CTA fusion during CTO PCI provided additional information regarding coronary arterial calcification and tortuosity that generated new insights into antegrade wiring, antegrade dissection/reentry, and retrograde wiring during CTO PCI. Overall CTO success rates and procedural outcomes remained similar between the two groups, despite a trend toward higher complexity in the fusion CTA group. This study demonstrates that real-time automated co-registration of coronary CTA centreline and calcification onto live fluoroscopic images is feasible and provides new insights into CTO PCI, and in particular, antegrade dissection reentry-based CTO PCI. • Real-time semi-automated fusion of CTA/fluoroscopy is feasible during CTO PCI. • CTA fusion data can be toggled on/off as desired during CTO PCI • Real-time CT calcium and centreline overlay could benefit antegrade dissection/reentry-based CTO PCI.

  11. Angiography in tumors of cartilaginous genesis

    International Nuclear Information System (INIS)

    Korolev, V.I.

    1986-01-01

    Angiography was used for 122 patients with tumors and tumor-like processes of the cartilage. Angiography was carried out by the S. Seldinger method. Normal angioarchitecture was observed in 16 patients with benign tumors (20 patients), characters of malignant tumor are determined in 4 patients. Normal angioarchitecture is determined in 9.4% of patients with chondrosarcoma (102 patients). The examination carried out showed that angiographic symptotics in chondrosarcomas varied depending on the stage, localization and the degree of morphologic differentiation

  12. Serum Zn levels in dysphagic patients who underwent endoscopic gastrostomy for long term enteral nutrition

    OpenAIRE

    Adriana Santos, Carla; Fonseca, Jorge; Brito, José; Fernandes, Tânia; Gonçalves, Luísa; Sousa Guerreiro, António

    2014-01-01

    Background and aims: Dysphagic patients who underwent endoscopic gastrostomy (PEG) usually present protein-energy malnutrition, but little is known about micronutrient malnutrition. The aim of the present study was the evaluation of serum zinc in patients who underwent endoscopic gastrostomy and its relationship with serum proteins, whole blood zinc, and the nature of underlying disorder. Methods: From patients that underwent gastrostomy a blood sample was obtained minutes before the procedur...

  13. Extrahepatic portal hypertension in childhood. Portographic findings and evaluation of hepatic blood flow by computerized radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Takehara, Hiroo; Komi, Nobuhiko; Goh, Masahiro; Yoshida, Sadahiro; Kameoka, Kazuhiro; Hino, Masao; Sui, Osamu

    1986-05-01

    Four pediatric patients with extrahepatic portal hypertension had undergone portography and computerized radionuclide angiography in order to examine shape of portal system and to evaluate hepatic blood flow before and aftersurgical treatment. In all patients, cavernous transformation of portal system was demonstrated by portography, and in one of them spontaneous splenorenal shunt occurred. In 3 of them, who underwent esophageal transsection combined with paraesophagogastric devascularization and splenectomy, so-called direct operation, increase of portal blood flow was revealed by computerized radionuclide angiography. It is suggested that direct operation increasing portal blood flow after surgery is effective in treating extrahepatic portal hypertension in childhood.

  14. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    International Nuclear Information System (INIS)

    Gao Sijia; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui; Zang Peizhuo; Shi Qiang; Wang Qiang; Liang Chuansheng; Xu Ke

    2009-01-01

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with χ 2 -test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show AVM not AVF. The

  15. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Gao Sijia [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)], E-mail: scarlettgao@126.com; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Zang Peizhuo [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Shi Qiang; Wang Qiang [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Liang Chuansheng [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Xu Ke [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)

    2009-07-15

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with {chi}{sup 2}-test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show

  16. Hyperhomocysteinemia in bilateral anterior ischemic optic neuropathy after conventional coronary artery bypass graft: a case report.

    Science.gov (United States)

    Niro, A; Sborgia, G; Sborgia, A; Alessio, G

    2018-01-17

    The incidence of anterior ischemic optic neuropathy after coronary artery bypass graft procedures ranges from 1.3 to 0.25%. The mechanisms of anterior ischemic optic neuropathy after cardiovascular procedures remain undefined but many systemic and related-to-surgery risk factors could underlie anterior ischemic optic neuropathy. In this case, we report a rare presentation of a bilateral anterior ischemic optic neuropathy after coronary artery bypass graft and speculate on the preoperative hyperhomocysteinemia as an independent risk factor for anterior ischemic optic neuropathy. A 56-year-old white man, a tobacco smoker with type 2 diabetes and coronary artery disease, underwent a conventional coronary artery bypass graft with extracorporeal circulation. In spite of ongoing anti-aggregation, antithrombotic, and vasodilator therapy, 10 days after the surgery he complained of severe bilateral visual loss. Funduscopy and fluorescein angiography revealed a bilateral anterior ischemic optic neuropathy. Analysis of preoperative laboratory tests revealed hyperhomocysteinemia. Hyperhomocysteinemia could increase the risk of ocular vascular damage and bilateral ocular involvement in patients who have undergone conventional coronary artery bypass graft.

  17. Magnetic resonance angiography of the extracranial carotid and vertebral arteries

    International Nuclear Information System (INIS)

    Akimura, Tatsuo; Saito, Kenichi; Nakayama, Hisato; Kashiwagi, Shiro; Kato, Shoichi; Ito, Haruhide.

    1994-01-01

    To evaluate the contribution of magnetic resonance angiography (MRA) in the screening study of the extracranial carotid and vertebral arteries using the conventional head and neck coils, 500 consecutive MRAs of the cervical vessels were performed using 1.5 tesla magnetic resonance unit with circularly polarized head coil. The 5 cm-thick imaging plane was placed in coronal fashion including both carotid and vertebral arteries. The imaging sequence was three-dimensional (3D) fast imaging with steady precession (FISP). In 10 patients with failed head coil examination, 10 patients with possible carotid and vertebral diseases and 10 volunteers, the extracranial carotid and vertebral arteries were examined with the Helmholtz neck coil. Both 3D- and 2D-FISP were performed in each case. The imaging plane was placed in oblique sagittal fashion. In 458 out of 500 cases (91.6%), the extracranial carotid and vertebral arteries were successfully depicted using head coil. In 20 patients with high shoulders, the carotid bifurcations were out of range of the head coil. In these cases, carotid bifurcations and the origins of the carotid and vertebral arteries were successfully revealed using a neck coil. To evaluate the stenotic lesions and tortuous vessels, 2D-FISP sequence seemed to be more suitable than 3D-FISP. Compared with conventional angiography, MRA caused overestimation of the degree of stenotic lesions. For screening examination of the extracranial carotid and vertebral arteries, most cases can be evaluated only with the conventional head coil. If depiction of the carotid bifurcation fails and the examination of carotids or vertebrals down to the aortic arch is needed, neck coil examination is required. (author)

  18. Diagnostic yield and accuracy of CT angiography, MR angiography, and digital subtraction angiography for detection of macrovascular causes of intracerebral haemorrhage: Prospective, multicentre cohort study

    NARCIS (Netherlands)

    C.J.J. Van Asch (Charlotte J.J.); B.K. Velthuis (Birgitta K.); G.J.E. Rinkel (Gabriël J.E.); A. Algra (Ale); G.A.P. de Kort (G. A P); T.D. Witkamp (Theo); J.C.M. De Ridder (Johanna C.M.); K.M. Van Nieuwenhuizen (Koen M.); F.-E. De Leeuw (Frank-Erik); W.J. Schonewille (Wouter); P.L.M. de Kort (Paul); D.W.J. Dippel (Diederik); T.W.M. Raaymakers (Theodora W.M.); J. Hofmeijer; M.J.H. Wermer (Marieke); H. Kerkhoff (Henk); K. Jellema (Korné); I.M. Bronner (Irene M.); M.J.M. Remmers (Michel ); H.P. Bienfait (Henri); R.J.G.M. Witjes (Ron J.G.M.); J.P. Greving (Jacoba); C.J.M. Klijn (Catharina J.M.); H.F. de Leeuw (Frank); H.B. Boogaarts; E.J. van Dijk (Ewoud); W.J. Schonewille; W.M.J. Pellikaan; C. Puppels-De Waard; P.L.M. De Kort; J.P. Peluso; J. van Tuijl (Jordie); J. Hofmeijer; F.B.M. Joosten (Frank); D.W.J. Dippel (Diederik); L. Khajeh (Ladbon); T.W.M. Raaijmakers; M.J. Wermer; M.A.A. van Walderveen (Marianne); H. Kerkhoff; E. Zock; K. Jellema (Korné); G.J. Lycklama à Nijeholt (Geert); I.M. Bronner; M.J.M. Remmers; R.J.G.M. Witjes; H.P. Bienfait; K.E. Droogh-Greve; R. Donders (Rogier); V.I.H. Kwa; T.H.C.M.L. Schreuder (Tobien H. C. M. L.); C.L. Franke (Cees); J.S. Straver; C. Jansen; S.L.M. Bakker (Stef); C.C. Pleiter (C.); M.C. Visser; C.J.J. Van Asch; B.K. Velthuis (Birgitta); G.J.E. Rinkel (Gabriel); K.M. Van Nieuwenhuizen; C.J.M. Klijn (Catharina J.M.)

    2015-01-01

    textabstractStudy question What are the diagnostic yield and accuracy of early computed tomography (CT) angiography followed by magnetic resonance imaging/angiography (MRI/MRA) and digital subtraction angiography (DSA) in patients with non-traumatic intracerebral haemorrhage? Methods This

  19. Multidetector CT angiography in living donor renal transplantation: accuracy and discrepancies in right venous anatomy.

    Science.gov (United States)

    Kulkarni, S; Emre, S; Arvelakis, A; Asch, W; Bia, M; Formica, R; Israel, G

    2011-01-01

    Multidetector computed tomography (MDCT) angiography is a reliable technique for assessing pre-operative renal anatomy in living kidney donors. The method has largely evolved into protocols that eliminate dedicated venous phase and instead utilize a combined arterial/venous phase to delineate arterial and venous anatomy simultaneously. Despite adoption of this protocol, there has been no study to assess its accuracy. To assess whether or not MDCT angiography compares favorably to intra-operative findings, 102 donors underwent MDCT angiography without a dedicated venous phase with surgical interpretation of renal anatomy. Anatomical variants included multiple arteries (12%), multiple veins (7%), early arterial bifurcation (13%), late venous confluence (5%), circumaortic renal veins (5%), retroaortic vein (1%), and ureteral duplication (2%). The sensitivity and specificity of multiple arterial anomalies were 100% and 97%, respectively. The sensitivity and specificity of multiple venous anomalies were 92% and 98%, respectively. The most common discrepancy was noted exclusively in the interpretation of right venous anatomy as it pertained to the renal vein/vena cava confluence (3%). MDCT angiography using a combined arterial/venous contrast-enhanced phase provides suitable depiction of renal donor anatomy. Careful consideration should be given when planning a right donor nephrectomy whether the radiographic interpretation is suggestive of a late confluence. © 2010 John Wiley & Sons A/S.

  20. Characteristics of myocardial perfusion imaging and coronary artery angiography in patients of NIDDM complicated with AMI

    International Nuclear Information System (INIS)

    Zhao Peiqin; Zhao Jinhua; Qin Mingzhao; Dai HaoJie; Zhang Runwu; Xiao Fen

    2001-01-01

    Objective: To investigate the characteristic changes of myocardial perfusion imaging and coronary artery angiography in patients of acute myocardial infarction (AMI) with underlined type 2 diabetes mellitus. Methods: 25 type 2 diabetes mellitus patients were enrolled for having clinical manifestation of AMI. Ten inpatients with AMI of simple coronary heart disease origin were served as controls. All subjects underwent both myocardial perfusion imagings (resting and nitroglycerine invention) and coronary artery angiography. Results: Compared to controls (40%), type 2 diabetes mellitus + AMI group had higher rate of multivessel disease (60%). For type 2 diabetes mellitus + AMI patients, 129/400 segments (32.25%) showed fixed defect, 25/160 segments (15.62%) in controls. Conclusions: For type 2 diabetes mellitus + AMI group, myocardial perfusion defects are widely distributed and multivessel or severe stenosis is more often presented. Good correlation exists between abnormal segments and angiographic lesions in both the number of segments involved and the severity of the lesions. Radionuclide myocardial perfusion is therefore considered a useful screening test not inferior to angiography, especially for those who are not tolerant enough to undergoing angiography

  1. Digital angiography of camel foot

    International Nuclear Information System (INIS)

    Dehghani, S.N.; Kohkiloyehzadeh, M.; Sazmand, A.

    2011-01-01

    In this study, angiography of normal digits of camel has been accomplished, and the vessels of digits and its distribution have been evaluated to be compared with abnormal digits in the future studies. The thoracic and pelvic limb of 16 camels were collected immediately following slaughter. The palmar and plantar arteries were isolated and catheterised by 18-gauge angiocatheter needle; perfused by 40Ð’–50 ml of iodinated compound injected into each vessel. Angiograms were obtained using dorsopalmer, dorsoplanter and latero-medial projections. In the pelvic limb, above the fetlock joint, the deep palmar arch communicates with the median artery via the anastomotic branch, forming the superfcial palmar arch, from which two branches were clear, 1-palmar common digital artery IV that divides into palmar proper digital arteries IV and V, close to the lateral accessory (ffth) digit. 2-Palmar common digital artery III, produces the first branch and continues distally near the middle of the proximal phalanx, it gives off two palmar branches of the proximal phalanx. Vascular distribution of the pelvic limb was similar to thoracic limb, carrying the name of plantar instead of palmar

  2. Preoperative evaluation of neurovascular relationship by using contrast-enhanced and unenhanced 3D time-of-flight MR angiography in patients with trigeminal neuralgia

    International Nuclear Information System (INIS)

    Qin, Zhou; Zhiling, Liu; Chuanfu, Li; Qingshi Zeng; Chuncheng, Qu; Shilei, Ni

    2011-01-01

    Background Microvascular decompression is an etiological strategy for the therapy of trigeminal neuralgia (TN). Preoperative identification of neurovascular compression, therefore, could have an impact on the determination of appropriate treatment for TN. Purpose To evaluate the value of contrast-enhanced and unenhanced three-dimensional (3D) time-of-flight (TOF) MR angiography in the visualization of neurovascular relationship in patients with TN. Material and Methods Thirty-seven patients with unilateral TN underwent unenhanced and contrast-enhanced 3D TOF MR angiography with a 3.0-T MR system. Images were reviewed by a radiologist blinded to clinical details. Vascular contact with the trigeminal nerve was identified, and the nature of the involved vessels (artery or vein) was determined. All patients underwent microvascular decompression. Results In 37 patients with TN, contrast-enhanced 3D TOF MR angiography identified surgically verified neurovascular contact in 35 of 36 symptomatic nerves, and there was no false-positive. Based on surgical findings, the sensitivity of MR imaging was 97.2% and specificity 100%. The nature of the offending vessel was correctly identified in 94.4% of the patients by using the combination of contrast-enhanced and unenhanced MR angiography. Conclusion Contrast-enhanced 3D TOF MR angiography is useful in the detection of vascular contact with the trigeminal nerve in patients with TN, and this MR imaging in combination with unenhanced MR angiography could help in the identification of the nature of the responsible vessels

  3. Low-dose prospectively electrocardiogram-gated axial dual-source CT angiography in patients with pulsatile bilateral bidirectional Glenn Shunt: an alternative noninvasive method for postoperative morphological estimation.

    Directory of Open Access Journals (Sweden)

    Xiaopeng Ji

    Full Text Available To explore the clinical value of low-dose prospectively electrocardiogram-gated axial dual-source CT angiography (low-dose PGA scanning, CTA in patients with pulsatile bilateral bidirectional Glenn shunt (bBDG as an alternative noninvasive method for postoperative morphological estimation.Twenty patients with pulsatile bBDG (mean age 4.2±1.6 years underwent both low-dose PGA scanning and conventional cardiac angiography (CCA for the morphological changes. The morphological evaluation included the anatomy of superior vena cava (SVC and pulmonary artery (PA, the anastomotic location, thrombosis, aorto-pulmonary collateral circulation, pulmonary arteriovenous malformations, etc. Objective and subjective image quality was assessed. Bland-Altman analysis and linear regression analyses were used to evaluate the correlation on measurements between CTA and CCA. Effective radiation dose of both modalities was calculated.The CT attenuation value of bilateral SVC and PA was higher than 300 HU. The average subjective image quality score was 4.05±0.69. The morphology of bilateral SVC and PA was displayed completely and intuitively by CTA images. There were 24 SVC above PA and 15 SVC beside PA. Thrombosis was found in 1 patient. Collateral vessels were detected in 13 patients. No pulmonary arteriovenous malformation was found in our study. A strong correlation (R2>0.8, P0.The mean effective dose of CTA and CCA was 0.50±0.17 mSv and 4.85±1.34 mSv respectively.CT angiography with a low-dose PGA scanning is an accurate and reliable noninvasive examination in the assessment of morphological changes in patients with pulsatile bBDG.

  4. Usefulness of MR angiography in cases of central vertigo.

    Science.gov (United States)

    Fujita, Nobuya; Yamanaka, Toshiaki; Hosoi, Hiroshi

    2002-07-01

    Syndromal vertigo is defined as a combination of vestibular function disturbance and cranial nerve or cerebral function disturbance. There is evidence that MR angiography (MRA), providing angiogram-like images of the intracranial and extracranial arterial flow, could replace invasive methods for diagnosing central vertigo. The purpose of this study was to provide simplified MRA criteria for identifying morbidity and to analyze the relation between imaging findings and clinical manifestations. Thirty-three individuals with symptoms of syndromal vertigo and vertebrobasilar territory disease were examined by equilibriometry, MR imaging (MRI) and MRA. Under MRA, vertebral artery (VA) stenosis was more common than VA occlusion (23 vs. nine cases, respectively). A basilar artery (BA) deviation was found in eight cases (24.2%). Twenty-five VA or BA abnormalities (75.8%) were found, and eight combined VA and BA abnormalities (24.2%) were found. We emphasize three points as follows. MRA is advantageous over conventional angiography for less invasive method. MRA can reveal abnormalities even in cases of 'solo-vertigo' with no observed neurologic abnormalities. In our series, abnormalities were confirmed by MRA even in cases with no concomitant such as hypertension, coronary heart disease, or diabetes mellitus, which are regarded as latent risk factors for stroke.

  5. Recent advances in contrast-enhanced magnetic resonance angiography

    International Nuclear Information System (INIS)

    Meaney, J.F.M.; Goyen, M.

    2007-01-01

    Magnetic resonance angiography (MRA) provides a means of visualizing vascular structures noninvasively and is increasingly replacing conventional X-ray angiography in routine use. Contrast-enhanced MRA (CE-MRA), in which gadolinium contrast agents are used to shorten the T1 relaxation, offers increased resolution and higher signal-to-noise ratio compared with earlier flow-dependent [time-of-flight (TOF) or phase-contrast (PC)] techniques. Currently available contrast agents differ in their ability to lower T1 values, and hence the choice of contrast agent is an important consideration in the successful use of CE-MRA. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first of a new class of intravascular contrast agents. This agent is extensively (approximately 85%) and reversibly bound to human serum albumin and is retained within the vasculature thus allowing steady-state imaging to be perform-ed. An additional benefit is that gado0fosveset offers higher relaxivity compared with other contrast agents, thus giving a lower blood T1 values which also makes it ideal for first-pass imaging. Clinical trials have consistently shown that gadofosveset enhanced MRA is more sensitive, specific and accurate than time-of-flight MRA, gives fewer uninterpretable scans and affords greater diagnostic confidence. Intravascular contrast agents such as gadofosveset, therefore, offer the potential for improved vascular imaging. (orig.)

  6. Robotic digital subtraction angiography systems within the hybrid operating room.

    Science.gov (United States)

    Murayama, Yuichi; Irie, Koreaki; Saguchi, Takayuki; Ishibashi, Toshihiro; Ebara, Masaki; Nagashima, Hiroyasu; Isoshima, Akira; Arakawa, Hideki; Takao, Hiroyuki; Ohashi, Hiroki; Joki, Tatsuhiro; Kato, Masataka; Tani, Satoshi; Ikeuchi, Satoshi; Abe, Toshiaki

    2011-05-01

    Fully equipped high-end digital subtraction angiography (DSA) within the operating room (OR) environment has emerged as a new trend in the fields of neurosurgery and vascular surgery. To describe initial clinical experience with a robotic DSA system in the hybrid OR. A newly designed robotic DSA system (Artis zeego; Siemens AG, Forchheim, Germany) was installed in the hybrid OR. The system consists of a multiaxis robotic C arm and surgical OR table. In addition to conventional neuroendovascular procedures, the system was used as an intraoperative imaging tool for various neurosurgical procedures such as aneurysm clipping and spine instrumentation. Five hundred one neurosurgical procedures were successfully conducted in the hybrid OR with the robotic DSA. During surgical procedures such as aneurysm clipping and arteriovenous fistula treatment, intraoperative 2-/3-dimensional angiography and C-arm-based computed tomographic images (DynaCT) were easily performed without moving the OR table. Newly developed virtual navigation software (syngo iGuide; Siemens AG) can be used in frameless navigation and in access to deep-seated intracranial lesions or needle placement. This newly developed robotic DSA system provides safe and precise treatment in the fields of endovascular treatment and neurosurgery.

  7. Study of spatial resolution in three-dimensional rotational angiography

    International Nuclear Information System (INIS)

    Enoki, Takuya; Nasada, Toshiya; Matsumoto, Kazuma; Umehara, Takayoshi

    2006-01-01

    In interventional radiology (IVR) of cerebral aneurysms, it is important to understand the form and physical relationships between the cerebral aneurysm and the surrounding vessels. However, because the vessels in the head area are highly complex, it can be difficult to comprehend the structure using conventional angiography. Therefore, three-dimensional rotational angiography (3D-RA) has been used in recent years. This article discusses studies of the spatial resolution of 3D-RA. We reconstructed 3D-RA of an acrylic slit phantom (slit widths: 0.5, 0.75, 1.0, 1.5 mm) and examined spatial resolution by visual evaluation and profile curves. When the slit phantom was arranged to avoid the effect of beam hardening, the spatial resolution of 3D-RA was found to be as high as 0.75 mm. When the slit phantom was placed orthogonal to the rotational axis of the C-arm, the spatial resolution of 3D-RA was decreased because of the cone angle effect of X-rays. However, it was considered within the allowable range for clinical study. Consequently, 3D-RA is valuable in IVR. (author)

  8. The application and the evaluation of digital subtraction angiography to flaps

    International Nuclear Information System (INIS)

    Hayashi, Akiteru; Maruyama, Yu; Onishi, Kiyoshi; Chang, Cheng-Chung; Iwahira, Yoshiko; Ebihara, Hirofumi; Sawaizumi, Masayuki

    1988-01-01

    We have performed intraarterial DSA (IADSA) for a pre-operative evaluation of vessels which supply donor or the recipient sites of flaps, and for the observation of patency of the anastomotic sites and graft vessels after a microsurgical free flap transfer. IADSA was found to offer equal and, sometimes even more valuable information than does conventional angiography. In all cases, the image quality satisfied our clinical demands. Because a diluted contrast media and a low dose injection of this contrast media was used, both the intensity of local heat sensation and pain were extremely low. Further, an IADSA can be safely performed on an outpatient basis if a 4-F high flow catheter is used. Thus, we have concluded that an IADSA has reported to be a useful and safe angiographic technic, and that it offers several advantages over conventional angiography. (author)

  9. Impact of Collateral Status Evaluated by Dynamic Computed Tomographic Angiography on Clinical Outcome in Patients With Ischemic Stroke

    NARCIS (Netherlands)

    van den Wijngaard, Ido R.; Boiten, Jelis; Holswilder, Ghislaine; Algra, Ale; Dippel, Diederik W J; Velthuis, Birgitta K.; Wermer, Marieke J H; van Walderveen, Marianne A A

    2015-01-01

    BACKGROUND AND PURPOSE—: Status of collateral circulation is a strong predictor of outcome after acute ischemic stroke. Our aim was to compare the predictive value of strategies for collateral blood flow assessment with dynamic computed tomographic angiography (CTA) and conventional single-phase CT

  10. Contrast media for left ventricular angiography. A comparison between Cardio-Conray and iopamidol.

    OpenAIRE

    Gwilt, D J; Nagle, R E

    1984-01-01

    Forty consecutive patients with coronary artery disease undergoing left ventricular angiography took part in a randomised double blind trial comparing a conventional contrast medium sodium meglumine iothalamate (Cardio-Conray) with the low osmolar agent iopamidol. Iopamidol produced a smaller rise in heart rate and a smaller fall in left ventricular systolic pressure, but the changes in left ventricular and diastolic pressure and maximum rate of change of pressure (dP/dt max) were not differe...

  11. Number and location of hepatic malignant lesions by computerized tomography-angiography

    International Nuclear Information System (INIS)

    Llauger, J.; Perez, C.; Castaner, E.; Coscojuela, P.; Marcos, J.A.; Pallardo, Y.; Traid, C.; Zidan, A.

    1991-01-01

    In order to perform surgical treatment of tumorous hepatic disease, primary or metastatic, the most accurate knowledge as possible of the number and location of lesions is needed. In that way, results provided by echography and conventional CT are not much precise, showing lasser that 60% of lessions. In this study CT-angiography technique, its indications, results and images obtained by this method are described. (Author)

  12. Complications with Outpatient Angiography and Interventional Procedures

    International Nuclear Information System (INIS)

    Young, Noel; Chi, Ka-Kit; Ajaka, Joe; McKay, Lesa; O'Neill, Diane; Wong, Kai Ping

    2002-01-01

    Purpose: To prospectively identify the complications, and rates of complication, in outpatient angiography and interventional procedures. Methods: There were 1050 consecutive patients, 646 men and 404 women, aged 17-89 years, with a total of 1239 procedures studied in a 2-year period, 1997 to 1999. Results: There were 560 cases of aorto-femoral angiography,resulting in 124 complications (22%), with pain or hematoma in 110.There were 206 cases of neck and cerebral angiography, resulting in 51 complications (25%), with pain and hematoma in 34, transient ischemic attack in 2 and cerebrovascular accident in 1. There were 197 interfentional procedures, with 177 being balloon dilatations, resulting in 68 complications (35%), with 2 having hematomas and 1 having hematoma/abscess requiring active treatment. There were 276 cases having various 'other' procedures (e.g., renal angiography),resulting in 65 complications (24%), with pain and hematoma in 61. No procedure-related death occurred. Eighteen cases (1.5%) had significant complications, with contrast allergy in eight. Conclusion: Outpatient angiography and intervention are relatively safe, with low significant complication rates

  13. MR angiography in tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Kalita, Jayantee; Prasad, Sreeram; Maurya, Pradeep K.; Misra, Usha K. (Dept. of Neurology, Sanjay Gandhi Post Graduate Inst. of Medical Sciences, Lucknow (India)), Email: drukmisra@rediffmail.com; Kumar, Sunil (Dept. of Radiodiagnosis, Sanjay Gandhi Post Graduate Inst. of Medical Sciences, Lucknow (India))

    2012-04-15

    Background: Infarctions in tuberculous meningitis (TBM) are common but there is a paucity of studies on MR angiography (MRA). Purpose: To evaluate the pattern and predictors of MRA abnormality in patients with TBM. Material and Methods: Sixty-seven patients with TBM were subjected to clinical, laboratory, magnetic resonance imaging (MRI), and MRA evaluation. The severity of meningitis, focal deficit, CSF findings, and stroke co-morbidities were recorded. Presence of exudates, infarction, hydrocephalous, and tuberculoma on MRI were noted. On intracranial MRA, occlusion or more than 50% narrowing of proximal middle cerebral artery (MCA), anterior cerebral artery (ACA) and posterior cerebral artery (PCA), and basilar artery were considered abnormal. The MRA abnormality was correlated with clinical, laboratory, and MRI findings. Results: Sixty-seven patients, aged 3-75 years (median 34 years) were included. MRI was abnormal in 61 (91%) patients; basal exudates in 24, hydrocephalous in 23, tuberculoma in 33, and infarction in 40. MRA was abnormal in 34 (50.7%); MCA was most commonly involved (n = 21), followed by PCA (n = 14), ICA (n = 8), ACA (n 5), basilar artery (n = 5), and vertebral and superior cerebellar artery (1 each). One-fourth of the patients had abnormality in both anterior and posterior circulations. MRA abnormality was related to hydrocephalous and infarction; corresponding infarct was present in 61.8% patients; 41.7% patients with abnormal MRA developed infarct at 3 months but none with normal MRA. Conclusion: Half the patients with TBM had MRA abnormality involving both anterior and posterior circulations and 61.8% of them had corresponding infarcts

  14. Method and apparatus for performing digital intravenous subtraction angiography

    International Nuclear Information System (INIS)

    Stein, J.A.

    1986-01-01

    This invention relates to digital intravenous subtraction angiography (DISA), and more particularly concerns novel apparatus and techniques for providing high resolution angiograms with equipment that coacts with existing standard medical X-ray equipment. A typical medical X-ray generator provides low mA, continuous X-ray exposures illuminating a standard image intensifier producing an image scanned by a conventional television camera to produce a video signal. An analog-to-digital converter digitizes the signal, and adding means adds the digital frame signals together in real time to provide an intermediate digital signal representing the addition of 5 to 20 frames. Digital storage means store the intermediate image signals. Preferably there are two system memories with means for summing a subsequent intermediate image in the second memory while a previously-formed intermediate image is being transferred to disk storage

  15. Correlation between coronary computed tomographic angiography and fractional flow reserve

    DEFF Research Database (Denmark)

    Kristensen, Thomas Skaarup; Engstrøm, Thomas; Kelbæk, Henning

    2010-01-01

    Coronary CT angiography (CCTA) has become an important modality to evaluate the presence of coronary artery disease. Coronary artery stenosis of intermediate severity remains a therapeutic dilemma. Measurement of fractional flow reserve (FFR) during coronary angiography is the most established...

  16. Renal computed angiography. Part I: Renal CT phlebography. Renal veins variants

    International Nuclear Information System (INIS)

    Al-Amin, M.; Krupev, M.; Hadjidekov, V.; Plachkov, I.

    2012-01-01

    The changing trend in renal surgery, transplantation and minimal invasive urology implies preprocedure evaluation of renal veins. Development of imaging methods offers new possibilities for venographic visualization. The goal of this study is to present authors experience in visualization of renal veins using 64 MDCT and to evaluate the utility in assessments of their variants. 128 patients (68 females and 60 males, mean age 53,3) with urological complaints underwent 64MDCT examination including CT angiography. Contrast enhancement includes 3-4ml/sec injection flow of 90 ml contrast medium followed by 20 ml saline at the same rate. In 23 out of 128 examined patients some of the common variants of the renal vein is found. 64 MDCT angiography visualize very well renal veins and becomes method of choice in preoperative assessment of renal vein anatomy. (authors)

  17. Computed Tomographic Perfusion Improves Diagnostic Power of Coronary Computed Tomographic Angiography in Women

    DEFF Research Database (Denmark)

    Penagaluri, Ashritha; Higgins, Angela Y.; Vavere, Andrea L

    2016-01-01

    laboratories. Prevalence of flow-limiting CAD defined by invasive coronary angiography equal to 50% or greater with an associated single-photon emission computed tomography myocardial perfusion imaging defect was 45% (114/252) and 23% (30/129) in males and females, respectively. Patient-based diagnostic......Background-Coronary computed tomographic angiography (CTA) and myocardial perfusion imaging (CTP) is a validated approach for detection and exclusion of flow-limiting coronary artery disease (CAD), but little data are available on gender-specific performance of these modalities. In this study, we...... aimed to evaluate the diagnostic accuracy of combined coronary CTA and CTP in detecting flow-limiting CAD in women compared with men.  Methods and Results-Three hundred and eighty-one patients who underwent both CTA-CTP and single-photon emission computed tomography myocardial perfusion imaging...

  18. The optimal project position for demonstrating tricuspid annulus in angiography: an experimental study

    International Nuclear Information System (INIS)

    Bai Yuan; Zong Gongjun; Wang Hongru; Qin Yongwen; Huang Xinmiao; Jiang Haibin

    2009-01-01

    Objective: To explore the optimal project position for demonstrating tricuspid annulus angiographically in experimental goats. Methods: Eight healthy goats underwent right atrial angiography by using 6 F pig tail catheters. Under fluoroscopic monitoring the contrast media (total 110 ml, flow rate 12 ml/ s, pressure 800 psi) was injected continuously while a serious exposures were performed from RAO position to LAO position (totally 180 degree rotation). The maximum diameter of the tricuspid annulus in every picture was measured and the results were compared with that obtained from sonography. Results: The procedure was successful in all 8 experimental goats. The optimal project position to display the tricuspid annulus was at 27 degree ± 3 degree in RAO position. Conclusion: In angiography, the tricuspid annulus can be best demonstrated at the project position of 27 degree ± 3 degree in RAO. (authors)

  19. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Rajaram, Smitha [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Academic Unit of Radiology, C Floor, Royal Hallamshire Hospital, Sheffield (United Kingdom); Swift, Andrew J.; Wild, Jim M. [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Capener, David; Telfer, Adam [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Davies, Christine; Hill, Catherine [Sheffield Teaching Hospitals Trust, Department of Radiology, Sheffield (United Kingdom); Condliffe, Robin; Elliot, Charles; Kiely, David G. [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Hurdman, Judith [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom)

    2012-02-15

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  20. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Rajaram, Smitha; Swift, Andrew J.; Wild, Jim M.; Capener, David; Telfer, Adam; Davies, Christine; Hill, Catherine; Condliffe, Robin; Elliot, Charles; Kiely, David G.; Hurdman, Judith

    2012-01-01

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  1. Diagnostic accuracy of second-generation dual-source computed tomography coronary angiography with iterative reconstructions: a real-world experience.

    Science.gov (United States)

    Maffei, E; Martini, C; Rossi, A; Mollet, N; Lario, C; Castiglione Morelli, M; Clemente, A; Gentile, G; Arcadi, T; Seitun, S; Catalano, O; Aldrovandi, A; Cademartiri, F

    2012-08-01

    The authors evaluated the diagnostic accuracy of second-generation dual-source (DSCT) computed tomography coronary angiography (CTCA) with iterative reconstructions for detecting obstructive coronary artery disease (CAD). Between June 2010 and February 2011, we enrolled 160 patients (85 men; mean age 61.2±11.6 years) with suspected CAD. All patients underwent CTCA and conventional coronary angiography (CCA). For the CTCA scan (Definition Flash, Siemens), we use prospective tube current modulation and 70-100 ml of iodinated contrast material (Iomeprol 400 mgI/ ml, Bracco). Data sets were reconstructed with iterative reconstruction algorithm (IRIS, Siemens). CTCA and CCA reports were used to evaluate accuracy using the threshold for significant stenosis at ≥50% and ≥70%, respectively. No patient was excluded from the analysis. Heart rate was 64.3±11.9 bpm and radiation dose was 7.2±2.1 mSv. Disease prevalence was 30% (48/160). Sensitivity, specificity and positive and negative predictive values of CTCA in detecting significant stenosis were 90.1%, 93.3%, 53.2% and 99.1% (per segment), 97.5%, 91.2%, 61.4% and 99.6% (per vessel) and 100%, 83%, 71.6% and 100% (per patient), respectively. Positive and negative likelihood ratios at the per-patient level were 5.89 and 0.0, respectively. CTCA with second-generation DSCT in the real clinical world shows a diagnostic performance comparable with previously reported validation studies. The excellent negative predictive value and likelihood ratio make CTCA a first-line noninvasive method for diagnosing obstructive CAD.

  2. Evaluation of left ventricular function by digital subtraction angiography

    International Nuclear Information System (INIS)

    Kuribayashi, Sachio; Ootaki, Makoto; Matsuyama, Seiya; Kanemoto, Nariaki; Furuya, Hideo

    1985-01-01

    Effects of contrast medium doses on left ventriculographic images using intravenous digital subtraction angiography (IVDSA-LVG) were assessed. The validity of IVDSA-LVG in evaluating ejection fraction (FF) and left ventricular regional wall motion was determined by comparison with conventional left ventriculography using direct injection (direct LVG). The advantages of left ventriculography using intraarterial subtraction angiography (IADSA-LVG) performed by injecting small doses of contrast media directly into the left ventricle were stressed. 1. To assess the effects of doses of contrast media on IVDSA-LVG, 10, 20, and 30 ml Urografin-76 were injected into the superior vena cava in 16 patients, and the resulting images were compared in each patient. With only 10 ml contrast medium, left ventricular opacification was fairly good, and regional wall motion was evaluated in many cases, but 30 ml were needed to calculate ventricular volume and EF. 2. To determine the validity of IVDSA-LVG in evaluating EF and regional wall motion, we compared IVDSA-LVG using 30 ml of contrast medium with direct LVG in 18 patients. There was a good correlation between the two methods in determining EF (r = 0.877), and 90 % of the interpretations of regional wall motion were in agreement by the two methods. IVDSA-LVG was useful and accurate in evaluating EF and regional wall motion of the left ventricle. 3. IADSA-LVG was performed for five patients, and good quality images were obtained in many cases, even with relatively small doses (10 ml) of contrast media. These results suggested that this method may be used in cases with impaired LV function, to avoid hemodynamic derangement induced by conventional direct LVG using large doses of contrast medium. (author)

  3. Rotational Angiography Based Three-Dimensional Left Atrial Reconstruction: A New Approach for Transseptal Puncture.

    Science.gov (United States)

    Koektuerk, Buelent; Yorgun, Hikmet; Koektuerk, Oezlem; Turan, Cem H; Gorr, Eduard; Horlitz, Marc; Turan, Ramazan G

    2016-02-01

    Rotational angiography is a well-known method for the three-dimensional (3-D) reconstruction of left atrium and pulmonary veins during left-sided atrial arrhythmia ablation procedures. In our study, we aimed to review our experience in transseptal puncture (TSP) using 3-D rotational angiography. We included a total of 271 patients who underwent atrial fibrillation ablation using cryoballoon. Rotational angiography was performed to get the three-dimensional left atrial and pulmonary vein reconstructions using cardiac C-arm computed tomography. The image reconstruction was made using the DynaCT Cardiac software (Siemens, Erlangen, Germany). The mean age of the study population was 61 ± 10 years. The indications for left atrial arrhythmia ablation were paroxysmal AF in 140 patients (52%) and persistent AF patients in 131 (48%) patients. The success rate of TSP using only rotational guidance was (264/271 patients, 97.4%). In the remaining seven patients, transesophageal guidance was used after the initial attempt due to thick interatrial septum in five patients and difficult TSP due to abnormal anatomy and mild pericardial effusion in the remaining two patients. Mean fluoroscopy dosage of the rotational angiography was 4896.4 ± 825.3 μGym(2). The mean time beginning from femoral vein puncture to TSP was 12.3 ± 5.5 min. TSP guided by rotational angiography is a safe and effective method. Our results indicate that integration of rotational angiographic images into the real-time fluoroscopy can guide the TSP during the procedure. © 2015 John Wiley & Sons Ltd.

  4. High-resolution ex vivo magnetic resonance angiography: a feasibility study on biological and medical tissues

    Directory of Open Access Journals (Sweden)

    Boel Lene WT

    2010-03-01

    Full Text Available Abstract Background In biomedical sciences, ex vivo angiography is a practical mean to elucidate vascular structures three-dimensionally with simultaneous estimation of intravascular volume. The objectives of this study were to develop a magnetic resonance (MR method for ex vivo angiography and to compare the findings with computed tomography (CT. To demonstrate the usefulness of this method, examples are provided from four different tissues and species: the human placenta, a rice field eel, a porcine heart and a turtle. Results The optimal solution for ex vivo MR angiography (MRA was a compound containing gelatine (0.05 g/mL, the CT contrast agent barium sulphate (0.43 mol/L and the MR contrast agent gadoteric acid (2.5 mmol/L. It was possible to perform angiography on all specimens. We found that ex vivo MRA could only be performed on fresh tissue because formalin fixation makes the blood vessels permeable to the MR contrast agent. Conclusions Ex vivo MRA provides high-resolution images of fresh tissue and delineates fine structures that we were unable to visualise by CT. We found that MRA provided detailed information similar to or better than conventional CTA in its ability to visualize vessel configuration while avoiding interfering signals from adjacent bones. Interestingly, we found that vascular tissue becomes leaky when formalin-fixed, leading to increased permeability and extravascular leakage of MR contrast agent.

  5. Optical Coherence Tomography Angiography in Retinal Vascular Diseases and Choroidal Neovascularization

    Directory of Open Access Journals (Sweden)

    Rodolfo Mastropasqua

    2015-01-01

    Full Text Available Purpose. To assess the ability of optical coherence tomography-angiography (OCT-A to show and analyze retinal vascular patterns and the choroidal neovascularization (CNV in retinal vascular diseases. Methods. Seven eyes of seven consecutive patients with retinal vascular diseases were examined. Two healthy subjects served as controls. All eyes were scanned with the SD-OCT XR Avanti (Optovue Inc, Fremont CA, USA. Split spectrum amplitude decorrelation angiography algorithm was used to identify the blood flow within the tissue. Fluorescein angiography (FA and indocyanine green angiography (ICGA with Spectralis HRA + OCT (Heidelberg Engineering GmbH were performed. Results. In healthy subjects OCT-A visualized major macular vessels and detailed capillary networks around the foveal avascular zone. Patients were affected with myopic CNV (2 eyes, age-related macular degeneration related (2, branch retinal vein occlusion (BRVO (2, and branch retinal artery occlusion (BRAO (1. OCT-A images provided distinct vascular patterns, distinguishing perfused and nonperfused areas in BRVO and BRAO and recognizing the presence, location, and size of CNV. Conclusions. OCT-A provides detailed images of retinal vascular plexuses and quantitative data of pathologic structures. Further studies are warranted to define the role of OCT-A in the assessment of retinovascular diseases, with respect to conventional FA and ICG-A.

  6. Videodensitometric quantitative angiography after coronary balloon angioplasty, compared to edge-detection quantitative angiography and intracoronary ultrasound imaging

    NARCIS (Netherlands)

    Peters, R. J.; Kok, W. E.; Pasterkamp, G.; von Birgelen, C.; Prins, M. [=Martin H.; Serruys, P. W.

    2000-01-01

    AIMS: To assess the value of videodensitometric quantification of the coronary lumen after angioplasty by comparison to two other techniques of coronary artery lumen quantification. METHODS AND RESULTS: Videodensitometric quantitative angiography, edge detection quantitative angiography and 30 MHz

  7. Selective angiography in fifty patients with primary hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Shou-Zhong, Wang; Xing-Rong, Chen; Gong-Xian, Wang

    1983-06-01

    Selective angiography is of great importance in the diagnosis of primary hepatocellular carcinoma. It offers information on the findings, multicentricity, localisation, extension, and type of growth. This paper discusses angiography from the methodical point of view, the findings to be obtained, the types of hepatocellular carcinoma, and the diagnostic efficiency of selective angiography in the evaluation of this type of tumour.

  8. Digital substraction angiography (DSA) in a universal radiodiagnostic room with a novel multi-pulse high-frequency generator

    International Nuclear Information System (INIS)

    Ellegast, H.H.; Kloss, R.; Mayr, H.; Ammann, E.; Kuehnel, W.; Siemens A.G., Erlangen

    1985-01-01

    Application of digital subtraction angiography in a universal radiodiagnostic room can be implemented rapidly and reliably. The number of examinations could be increased without negative effects to conventional operations in this room. At optimum radiation hygiene and high-degree operational safety, the multipulse high-frequency generator with its DSA parameter automatic system guarantees a reproducibly good image quality equalling that of a special DSA facility. In this way, the examination room constitutes an economic solution for small-sized hospitals without any special angiography room, too. (orig.) [de

  9. Visualization of coronary arteries in patients after childhood Kawasaki syndrome: value of multidetector CT and MR imaging in comparison to conventional coronary catheterization

    International Nuclear Information System (INIS)

    Arnold, Raoul; Ley, Sebastian; Ley-Zaporozhan, Julia; Kauczor, Hans-Ulrich; Eichhorn, Joachim; Ulmer, Herbert; Schenk, Jens-Peter

    2007-01-01

    After childhood Kawasaki syndrome (KS) the coronary arteries undergo a lifelong dynamic pathological change, and follow-up coronary artery imaging is essential. At present, conventional coronary catheterization (CCC) and angiography is still regarded as the gold standard. Less-invasive methods such as multidetector CT angiography (MDCT-A) and MRI have been used sporadically. To compare the diagnostic quality of MDCT-A and MRI with that of CCC for coronary imaging in a group of patients with coronary artery pathology after childhood KS. A total of 16 patients (aged 5-27 years) underwent CCC and 16-row MDCT-A and 14 patients MRI (1.5 T). There was 100% agreement between MDCT-A and CCC in the detection of coronary aneurysms and stenoses. MDCT-A was superior for the visualization of calcified lesions. MRI and CCC showed 93% agreement for the detection of aneurysms. Visualization of coronary artery stenoses was difficult using MRI - one stenosis was missed. MDCT-A has excellent correlation with CCC regarding all changes affecting the coronary arteries in the follow-up of childhood KS. In comparison to MDCT-A and CCC, MRI is less precise in the detection of stenotic lesions. Due to its high image quality and ease of performance MDCT-A should be the primary diagnostic modality in patients following childhood KS. (orig.)

  10. Correlation between Depth of Myocardial Bridging and Coronary Angiography Findings

    Energy Technology Data Exchange (ETDEWEB)

    Elmali, M.; Soylu, K.; Gulel, O.; Bayrak, I.K.; Koprulu, D.; Diren, H.B.; Celenk, C. (Dept. of Radiology and Dept. of Cardiology, Ondokuz Mayis Univ. Faculty of Medicine, Samsun (Turkey))

    2008-10-15

    Background: Myocardial bridging (MB) is a congenital anomaly in which a segment of coronary artery is surrounded by myocardium. Purpose: To investigate the correlation between muscle thickness over the tunneled coronary artery (depth) in MB and the presence of milking effect (ME) and systolic narrowing ratio in catheter angiography (CA). Material and Methods: The records of 36 patients who underwent a coronary computed tomography angiography (CTA) and following CA examination for suspicious ischemic coronary artery disease, between March 2005 and September 2007, were retrospectively evaluated. According to the depth of MB on CTA, patients were grouped into four groups: group 1, <1 mm; group 2, 1- <2 mm; group 3, 2- <4 mm; group 4, =4 mm. The presence of milking effect, systolic narrowing ratio, and atherosclerotic stenosis at CA were recorded. CTA and CA results were then compared to evaluate the correlation. Results: In total, ME was found in 15 arteries at CA (42%). There was no ME in group 1; it was present in 11% of group 2, 67% of group 3, and 100% of group 4. Starting from group 3, the percentage of likelihood of seeing the milking effect was 77%, and the percentage of systolic narrowing was between 30 and 70%. There was a significant correlation between depth of MB and systolic narrowing (P<0.01), while no significant correlation between length of MB and systolic narrowing was found (P=0.32). In seven of the 36 patients (group 1, 0; group 2, 1; group 3, 3; group 4, 3), clinical findings were related to pure MB. Conclusion: The depth of MB is positively related to coronary narrowing and clinical ischemic findings

  11. Detection of the source of hemorrhage using postmortem computerized tomographic angiography in a case of a giant juvenile nasopharyngeal angiofibroma after surgical treatment.

    Science.gov (United States)

    do Nascimento, Felipe Barjud Pereira; dos Santos, Glaucia Aparecida Bento; Melo, Nelson Almeida d'Ávila; Damasceno, Eduarda Bittencourt; Mauad, Thais

    2015-09-01

    Postmortem computerized tomographic angiography (PMCTA) has been increasingly used in forensic medicine to detect and locate the source of bleeding in cases of fatal acute hemorrhage. In this paper, we report a case of postoperative complication in a patient with a giant juvenile nasopharyngeal angiofibroma in which the source of bleeding was detected by PMCTA. A case description and evaluations of the pre- and postoperative exams, postmortem CT angiogram, and conventional autopsy results are provided. The source of bleeding was identified by postmortem CT angiography but not by conventional autopsy. The established protocol, injecting contrast medium into the femoral artery, was effective in identifying the source of bleeding. Postoperative bleeding is a rare and frequently fatal complication of juvenile nasopharyngeal angiofibroma. As a complement to conventional autopsy, postmortem angiography is a valuable tool for the detection of lethal acute hemorrhagic foci, and establishing a routine procedure for PMCTA may improve its efficiency.

  12. The detectability of the origin of the inferior phrenic artery by paging method on multidetector-row CT angiography

    International Nuclear Information System (INIS)

    Terayama, Koshi

    2005-01-01

    We evaluated the ability to detect the origin of the inferior phrenic artery (IPA) by paging method on multidetector-row computed tomography (CT) angiography. In 104 patients who underwent multidetector-row CT, detectability of the origin of the IPA was assessed. In addition, in 30 patients in whom arteriographic study was performed, the IPA findings on multidetector-row CT were compared with those on arteriography. In 100 patients (96%) the origin of the right IPA was demonstrated with multidetector-row CT and in 93 patients (89%) the origin of the left IPA was demonstrated. CT angiographic findings concurred with arteriographic findings in all 30 patients (100%) who underwent arteriographic study. In conclusion, paging method on multidetector-row CT angiography provides valuable anatomical information regarding IPA. (author)

  13. Transapical aortic valve implantation without angiography: proof of concept.

    Science.gov (United States)

    Ferrari, Enrico; Sulzer, Christopher; Marcucci, Carlo; Rizzo, Elena; Tozzi, Piergiorgio; von Segesser, Ludwig K

    2010-06-01

    Cardiac computed tomographic scans, coronary angiograms, and aortographies are routinely performed in transcatheter heart valve therapies. Consequently, all patients are exposed to multiple contrast injections with a following risk of nephrotoxicity and postoperative renal failure. The transapical aortic valve implantation without angiography can prevent contrast-related complications. Between November 2008 and November 2009, 30 consecutive high-risk patients (16 female, 53.3%) underwent transapical aortic valve implantation without angiography. The landmarks identification, the stent-valve positioning, and the postoperative control were routinely performed under transesophageal echocardiogram and fluoroscopic visualization without contrast injections. Mean age was 80.1 +/- 8.7 years. Mean valve gradient, aortic orifice area, and ejection fraction were 60.3 +/- 20.9 mm Hg, 0.7 +/- 0.16 cm(2), and 0.526 +/- 0.128, respectively. Risk factors were pulmonary hypertension (60%), peripheral vascular disease (70%), chronic pulmonary disease (50%), previous cardiac surgery (13.3%), and chronic renal insufficiency (40%) (mean blood creatinine and urea levels: 96.8 +/- 54 microg/dL and 8.45 +/- 5.15 mmol/L). Average European System for Cardiac Operative Risk Evaluation was 32.2 +/- 13.3%. Valve deployment in the ideal landing zone was 96.7% successful and valve embolization occurred once. Thirty-day mortality was 10% (3 patients). Causes of death were the following: intraoperative ventricular rupture (conversion to sternotomy), right ventricular failure, and bilateral pneumonia. Stroke occurred in one patient at postoperative day 9. Renal failure (postoperative mean blood creatinine and urea levels: 91.1 +/- 66.8 microg/dL and 7.27 +/- 3.45 mmol/L), myocardial infarction, and atrioventricular block were not detected. Transapical aortic valve implantation without angiography requires a short learning curve and can be performed routinely by experienced teams. Our report

  14. Contrast-enhanced MR angiography of abdominal vessels: Is there still a role for angiography?

    Energy Technology Data Exchange (ETDEWEB)

    Vosshenrich, R.; Fischer, U. [Department of Radiology, Georg-August-Universitaet Goettingen (Germany)

    2002-01-01

    The purpose of this review article is to describe recent advantages in contrast-enhanced (CE) three-dimensional (3D) magnetic resonance angiography (MRA) in comparison with other vascular imaging techniques, and to discuss their current clinical applications for the imaging of abdominal vessels. Principles and technical considerations are presented and clinical applications are reviewed for different vascular diseases. In ruptured aortic aneurysms and acute dissections CT is the method of first choice. Contrast-enhanced 3D MRA can be well used for therapeutic planning and follow-up in patients with stable disease. A comprehensive MR examination including CE 3D MRA, MR urography and MR nephrogram has the potential to replace the conventional studies for the evaluation of renal vascular disease. It is an accurate method for imaging the origins of coeliac and superior mesenteric arteries, although the image resolution is too low for reliable assessment of the inferior mesenteric artery. Contrast-enhanced 3D MRA has emerged as the method of choice for studying the portal venous system in liver transplant recipients, in patients with portal hypertension and in cases with abdominal tumours for preoperative evaluation. Additional non-invasive flow measurements are useful in monitoring portal hypertension. The abdominal veins can be well imaged using unenhanced MR techniques. Imaging may be facilitated with intravascular contrast media. Contrast-enhanced 3D MRA can replace intra-arterial DSA for diagnosis, therapy planning and follow-up in patients with abdominal vascular disease. Catheter-based arteriography will still be used for interventional procedures such as percutaneous transluminal angioplasty, stent placement and embolisation. (orig.)

  15. Hodgkin's disease following thorium dioxide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Gotlieb, A I; Kirk, M E [McGill Univ., Montreal, Quebec (Canada). Dept. of Pathology; Hutchison, J L [Montreal General Hospital, Quebec (Canada)

    1976-09-04

    Hodgkin's disease occurred in a 53-year-old man who, 25 years previously, had undergone cerebral angiography, for which thorium dioxide suspension (Thorotrast) was used. Deposits of thorium dioxide were noted in reticuloendothelial cells in various locations. An association between thorium dioxide administration and the subsequent development of malignant tumours and neoplastic hematologic disorders has previously been reported.

  16. Digital subtraction angiography: myths and reality

    International Nuclear Information System (INIS)

    Levin, D.C.

    1984-01-01

    Some of the claims made about digital subtraction angiography (DSA) when it was first developed have turned out to be greatly exaggerated, and some members of the radiologic community have become disillusioned with its capabilities. The author discusses some of the limitations of DSA, and concludes that the advantages of DSA outweigh its limitations

  17. Spiral CT-angiography of the aorta

    NARCIS (Netherlands)

    Balm, R.; Eikelboom, B. C.; van Leeuwen, M. S.; Noordzij, J.

    1994-01-01

    AIMS: To determine whether the new technique of CT-angiography was accurate in displaying the complex anatomy of the aorta and its major branches. METHODS: Seventeen patients with a variety of aortic pathology were examined. Using a spiral CT-scanner a volumetric scan was made during injection of

  18. Magnetic resonance angiography in meningovascular syphilis

    Energy Technology Data Exchange (ETDEWEB)

    Gallego, J [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Soriano, G [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Zubieta, J L [Servicio de Neuroradiologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Delgado, G [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain); Villanueva, J A [Servicio de Neurologia, Hospital de Navarra and Pamplona Univ. Hospital (Spain)

    1994-04-01

    Meningovascular neurosyphilis (MN) is an unusual cause of stroke in young adults. The clinical manifestations include prodromal symptoms weeks or months before definitive stroke. The diagnosis is based on clinical findings and examination of the serum and cerebrospinal fluid. We report a case of MN with basilar artery irregularities demonstrated by magnetic resonance angiography. (orig.)

  19. Vascular anatomy in angiography for magnetic resonance

    International Nuclear Information System (INIS)

    Charry Lopez, Marco Luciano; Rivera Gomez, Juan Enrique

    1998-01-01

    A review of basic anatomical concepts and main variants, as well as some anatomical anomalies of the central nervous system vascularity, these concepts are considered essential for the interpretation of magnetic resonance angiography with time-of-flight (TOF) and phase-contrast (PC) methods

  20. Digital subtraction angiography of carotid bifurcation

    International Nuclear Information System (INIS)

    Vries, A.R. de.

    1984-01-01

    This study demonstrates the reliability of digital subtraction angiography (DSA) by means of intra- and interobserver investigations as well as indicating the possibility of substituting catheterangiography by DSA in the diagnosis of carotid bifurcation. Whenever insufficient information is obtained from the combination of non-invasive investigation and DSA, a catheterangiogram will be necessary. (Auth.)

  1. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive ... possibility that you’re pregnant tell your doctor as well. On the day of your exam, it’s ...

  2. Post-mortem CT-coronary angiography

    DEFF Research Database (Denmark)

    Pøhlsgaard, Camilla; Leth, Peter Mygind

    2007-01-01

    post-mortem coronary angiography and computerized tomography.  We describe how to prepare and inject the contrast medium, and how to establish a CT-protocol that optimizes spatial resolution, low contrast resolution and noise level. Testing of the method on 6 hearts, showed that the lumen...

  3. Intraarterial tolazoline in angiography of the foot

    International Nuclear Information System (INIS)

    Neubauer, B.

    1978-01-01

    Foot angiography was performed in 32 diabetic patients with and without intraarterial injection of tolazoline (Priscoline). The angiographic quality was improved with tolazoline, manifested as an increased flow rate with acceleration of the arteriovenous transit time, a higher incidence of complete arterial filling with contrast medium in clinically important regions, and considerably longer arterial segments demonstrated within defined regions of measurement. (Auth.)

  4. Angiography and angiotherapy of gastrointestinal tract bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, R.; Grassot, A.; Souchon, R.

    1982-03-01

    In selected patients with upper and lower gastrointestinal hemorrhage there is an indication for angiography. Vasoconstrictive drugs or embolization materials can be submitted through the catheter to stop the hemorrhage (angiotherapy). 81 patients were diagnosed by this method. Treatment through the angiographic catheter followed the diagnostic procedure in 41 cases. The hemorrhage was controlled in 36 patients.

  5. Digital subtraction angiography: first 900 cases

    International Nuclear Information System (INIS)

    Rodgers, H.

    1984-01-01

    The diagnostic technique of digital subtraction angiography (DSA) is briefly outlined. The operational and technical experiences with a DR-960 DSA system used in the examination of the first 900 cases at St. Thomas' Hospital, London are described. (U.K.)

  6. Magnetic resonance angiography in meningovascular syphilis

    International Nuclear Information System (INIS)

    Gallego, J.; Soriano, G.; Zubieta, J.L.; Delgado, G.; Villanueva, J.A.

    1994-01-01

    Meningovascular neurosyphilis (MN) is an unusual cause of stroke in young adults. The clinical manifestations include prodromal symptoms weeks or months before definitive stroke. The diagnosis is based on clinical findings and examination of the serum and cerebrospinal fluid. We report a case of MN with basilar artery irregularities demonstrated by magnetic resonance angiography. (orig.)

  7. Two new contrast media in coronary angiography

    International Nuclear Information System (INIS)

    Selin, K.; Bjoerk, L.

    1983-01-01

    Amipaque, ioxaglic acid and Isopaque Coronar 300 were compared in a double blind investigation of coronary angiography in patients with ischemic heart disease. Amipaque affected systolic blood pressure and ECG less than the other contrast media. Ioxaglic acid appeared to give more ST and T changes than Isopaque Coronar. (Auth.)

  8. On the system of cine-angiography

    International Nuclear Information System (INIS)

    Wakamatsu, Koji; Togi, Hideaki; Yokoyama, Hironori

    1979-01-01

    National Institute of Circulatory Disease Centre have four angiography apparatuses which deal with more than 80 cases of cerebral blood vessel and 100 cases of heart blood vessel each month. Most of the angiography is cine-photography. Five more angiography apparatuses are expected to be operated in operation and RI examination rooms in the future. The problems on cine-angiography system were discussed as follows: (1) The proper dose must be chosen in order to obtain good quality of cine-images. (2) The cine resolution depends much on dose. (3) The lower X-ray tube voltage can give better contrast. (4) Suitable capacity for an X-ray tube is over 60 kW at 2 sec rating. (5) Cine-autophotography requires rapid response and a circuit for lock. (6) Influence of side scattering can be solved by a blanking circuit in biplane cine-photography. (7) Self-developing is desirable to improve the quality of cine-images. (Kobatake, H.)

  9. 16-Detector row computed tomographic coronary angiography in patients undergoing evaluation for aortic valve replacement: comparison with catheter angiography

    International Nuclear Information System (INIS)

    Manghat, N.E.; Morgan-Hughes, G.J.; Broadley, A.J.; Undy, M.B.; Wright, D.; Marshall, A.J.; Roobottom, C.A.

    2006-01-01

    Aim: To evaluate the diagnostic accuracy of 16-detector row computed tomography (CT) in assessing haemodynamically significant coronary artery stenoses in patients under evaluation for aortic stenosis pre-aortic valve replacement. Subjects and methods: Forty consecutive patients under evaluation for severe aortic stenosis and listed for cardiac catheterization before potential aortic valve replacement underwent coronary artery calcium (CAC) scoring and retrospective electrocardiogram (ECG)-gated multi-detector row computed tomographic coronary angiography (MDCTA) using a GE Lightspeed 16-detector row CT within 1 month of invasive coronary angiography (ICA) for comparative purposes. All 13 major coronary artery segments of the American Heart Association model were evaluated for the presence of ≥50% stenosis and compared to the reference standard. Data were analysed on a segment-by-segment basis and also in 'whole patient' terms. Results: A total of 412/450 segments from 35 patients were suitable for analysis. The overall accuracy of MDCTA for detection of segments with ≥50% stenosis was high, with a sensitivity of 81.3%, specificity 95.0%, positive predictive value (PPV) 57.8%, and negative predictive value (NPV) 98.4%. On a 'whole-patient' basis, 100% (19/19) of patients with significant coronary disease were correctly identified and there were no false-negatives. Excluding patients with CAC >1000 from the analysis improved the accuracy of MDCTA to: sensitivity 90%, specificity 98.1%, PPV 60%, NPV 99.7%. Conclusion: Non-invasive 16-detector row MDCTA accurately excludes significant coronary disease in patients with severe aortic stenosis undergoing evaluation before aortic valve replacement and in whom ICA can therefore be avoided. Its segment-by-segment accuracy is improved further if CAC > 1000 is used as a gatekeeper to MDCTA

  10. Detection of aneurysms in subarachnoidal hemorrhage - CT-angiography versus digital subtraction angiography

    International Nuclear Information System (INIS)

    Roehnert, W.; Haenig, V.; Hietschold, V.; Abolmaali, N.

    1998-01-01

    Purpose: The value of CT-angiography (CT-A) for the visualization of intracranial aneurysms was more closely defined by comparison with digital subtraction angiography (DSA). Methods: Over a period of 18 months a total of 106 patients in whom a subarachnoidal hemorrhage had been detected on native CT were examined in parallel by spiral CT and DSA. CT-angiography was performed under standardized parameters and included processing with 3D surface reconstructions. Results: In 64 patients (60.4%) at total of 72 aneurysms were detected. In four cases (6.2%) there were two and in two cases (3.1%) even three aneurysms. The findings of DSA and CTA agreed in 98 cases (92.5%). In four patients (3.8%) a false negative results was obtained in CTA and the initial DSA. Conclusions: Digital subtraction angiography must still be considered as the gold standard in the diagnosis of cerebral aneurysms. On account of its excellent spatial delineation of aneurysms and possibilities for exact measurements, CT-angiography represents a valuable, supplementary method - in some cases also an alternative method - to digital subtraction angiography. (orig.) [de

  11. Evaluation of the patency of an extracranial-intracranial bypass using magnetic resonance angiography with selective presaturation of bypass vessels

    Energy Technology Data Exchange (ETDEWEB)

    Mabuchi, Shoji; Nakayama, Naoki; Isu, Toyohiko; Harata, Tatsuo; Nanbu, Toshikazu [Kushiro Rousai Hospital, Hokkaido (Japan)

    1994-06-01

    Three-dimensional time-of-flight magnetic resonance (MR) angiography using radiofrequency presaturation pulses was used to evaluate the patency of extracranial-intracranial (EC/IC) bypass in 11 patients. Presaturation causes signal loss in the vascular territory supplied by the presaturated EC/IC bypass graft. In all patients with a patent EC/IC bypass graft confirmed on conventional angiography, disappearance of the signal of the middle cerebral artery receiving blood flow from the bypass graft was clearly observed on MR angiograms with presaturation, indicating patency of the EC/IC bypass graft. MR angiography with presaturation pulses is a noninvasive and repeatable method for evaluation of the function of an EC/IC bypass graft. (author).

  12. Coronary CT angiography: Diagnostic value and clinical challenges.

    Science.gov (United States)

    Sabarudin, Akmal; Sun, Zhonghua

    2013-12-26

    Coronary computed tomography (CT) angiography has been increasingly used in the diagnosis of coronary artery disease due to improved spatial and temporal resolution with high diagnostic value being reported when compared to invasive coronary angiography. Diagnostic performance of coronary CT angiography has been significantly improved with the technological developments in multislice CT scanners from the early generation of 4-slice CT to the latest 320- slice CT scanners. Despite the promising diagnostic value, coronary CT angiography is still limited in some areas, such as inferior temporal resolution, motion-related artifacts and high false positive results due to severe calcification. The aim of this review is to present an overview of the technical developments of multislice CT and diagnostic value of coronary CT angiography in coronary artery disease based on different generations of multislice CT scanners. Prognostic value of coronary CT angiography in coronary artery disease is also discussed, while limitations and challenges of coronary CT angiography are highlighted.

  13. Angiography in non-traumatic brain haematoma. An analysis of 100 cases

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, P.D. [Sheffield Univ. (United Kingdom). Academic Dept. of Radiology; Beveridge, C.J.; Gholkar, A. [Newcastle General Hospital, Newcastle upon Tyne (United Kingdom). Dept. of Neuroradiology

    1997-09-01

    Purpose: The primary purpose of this project was to study the anatomical characteristics of intracerebral haematoma (ICH) in order to determine features that may negate the need for angiography in some patients. Material and Methods: The study was prospective and designed to investigate the underlying cause of non-traumatic ICH in 100 cases assessed by conventional angiography. Patients were excluded if there was a history of trauma or known pre-existing brain abnormality. All patients were examined with CT and angiography within 4 days of the ictus. Results: Ruptured aneurysms or arteriovenous malformations (AVMs) were diagnosed on the initial angiogram in 49% of cases: 27 AVMs and 22 aneurysms. One case of superior sagittal sinus thrombosis was also detected. Vascular abnormalities were found most frequently in the under-40 age group and in cases in which subarachnoid haemorrhage, intraventricular haemorrhage or extracerebral haematoma accompanied the ICH. The temporal lobe was the most frequent anatomical location (37%). When a temporal lobe haematoma extended into the Sylvian fissure from the inferior pole of the temporal lobe or when it was associated with subarachnoid haemorrhage, structural abnormalities were found in over 90% of cases. Conclusions: There are groups of patients with ICH in whom the CT features are highly suggestive of AVM or aneurysm rupture. If the initial angiography is negative in these cases, careful follow up by repeat angiography and/or MR imaging is essential. However, potentially treatable abnormalities cannot be excluded with certainty by the distribution of the haematoma on CT alone, even if there is a history of pre-existing hypertension. (orig.).

  14. Angiography in non-traumatic brain haematoma. An analysis of 100 cases

    International Nuclear Information System (INIS)

    Griffiths, P.D.; Beveridge, C.J.; Gholkar, A.

    1997-01-01

    Purpose: The primary purpose of this project was to study the anatomical characteristics of intracerebral haematoma (ICH) in order to determine features that may negate the need for angiography in some patients. Material and Methods: The study was prospective and designed to investigate the underlying cause of non-traumatic ICH in 100 cases assessed by conventional angiography. Patients were excluded if there was a history of trauma or known pre-existing brain abnormality. All patients were examined with CT and angiography within 4 days of the ictus. Results: Ruptured aneurysms or arteriovenous malformations (AVMs) were diagnosed on the initial angiogram in 49% of cases: 27 AVMs and 22 aneurysms. One case of superior sagittal sinus thrombosis was also detected. Vascular abnormalities were found most frequently in the under-40 age group and in cases in which subarachnoid haemorrhage, intraventricular haemorrhage or extracerebral haematoma accompanied the ICH. The temporal lobe was the most frequent anatomical location (37%). When a temporal lobe haematoma extended into the Sylvian fissure from the inferior pole of the temporal lobe or when it was associated with subarachnoid haemorrhage, structural abnormalities were found in over 90% of cases. Conclusions: There are groups of patients with ICH in whom the CT features are highly suggestive of AVM or aneurysm rupture. If the initial angiography is negative in these cases, careful follow up by repeat angiography and/or MR imaging is essential. However, potentially treatable abnormalities cannot be excluded with certainty by the distribution of the haematoma on CT alone, even if there is a history of pre-existing hypertension. (orig.)

  15. [Clinical values of hemodynamics assessment by parametric color coding of digital subtraction angiography before and after endovascular therapy for critical limb ischaemia].

    Science.gov (United States)

    Su, Haobo; Lou, Wensheng; Gu, Jianping

    2015-10-06

    To investigate the feasibility of parametric color coding of digital subtraction angiography (Syngo iFlow) for hemodynamics assessment in patients with critical limb ischemia in pre- and post-endovascular therapy. To explore the correlation between Syngo iFlow and the conventional techniques. from January 2013 to December 2014, Clinical data of 21 patients with TASC II type B and type C femoropopliteal arteriosclerotic occlusive disease who were treated by percutaneous transluminal angioplasty and/or primary stent implantation in Nanjing first hospital were analyzed retrospectively. Of these patients there were 10 males and 11 females with an average age of (72±6) years (range from 58-85 years). The treatment efficacy was assessed by the variation of a series of clinical symptoms indexes (such as pain score, cold sensation score and intermittent claudication score), ankle braehial index (ABI) and transcutaneous oxygen pressure (TcPO2). Angiography was performed with the same protocol before and after treatment and parametric color coding of digital subtraction angiography was created by Syngo iFlow software on a dedicated workstation. The time to peak (TTP) of artery and tissue perfusion selected at the same regions of foot and ankle were measured and analyzed to evaluate the improvement of microcirculation and hemodynamics of the ischemic limb. The correlations between Syngo iFlow and the traditional clinical evaluation methods were explored using the Spearman rank correlation test. All patients (21 limbs) underwent successful endovaseular therapy. The mean pain score, cold sensation score, intermittent claudication score, ABI and TcPO2 before treatment were (0.48±0.68), (2.71±0.72), (2.86±0.85), ABI (0.33±0.07), TcPO2 (26.83±3.41) mmHg. While 1 week after treatment all above indicators were (2.57±0.93), (0.33±0.48), (0.90±0.54), (0.69±0.11), TcPO2 (53.75±3.60) mmHg respectively. There were significant statistical differences between pre- and post

  16. Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Julie M.; Vavere, Andrea L.; Arbab-Zadeh, Armin; Bush, David E.; Lardo, Albert C.; Texter, John; Brinker, Jeffery; Lima, Joao A.C. [Johns Hopkins Hospital, Johns Hopkins University, Department of Medicine, Division of Cardiology, Baltimore, MD (United States); Dewey, Marc [Charite - Universitaetsmedizin Berlin, Medical School, Humboldt-Universitaet und Freie Universitaet zu Berlin, Department of Radiology, Berlin, PO Box 10098 (Germany); Rochitte, Carlos E.; Lemos, Pedro A. [University of Sao Paulo Medical School, Heart Institute (InCor), Sao Paulo (Brazil); Niinuma, Hiroyuki [Iwate Medical University, Department of Cardiology, Morioka (Japan); Paul, Narinder [Toronto General Hospital, Department of Medical Imaging, Toronto (Canada); Hoe, John [Medi-Rad Associates Ltd, CT Centre, Mt Elizabeth Hospital, Singapore (Singapore); Roos, Albert de [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Yoshioka, Kunihiro [Iwate Medical University, Department of Radiology, Morioka (Japan); Cox, Christopher [Johns Hopkins Bloomberg School of Public Health, Department of Epidemiology, Baltimore, MD (United States); Clouse, Melvin E. [Harvard University, Department of Radiology, Beth Israel Deaconess, Boston, MA (United States)

    2009-04-15

    Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective ''CORE-64'' trial (''Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors''). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows. (orig.)

  17. Cost effectiveness of coronary angiography and calcium scoring using CT and stress MRI for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Dewey, Marc; Hamm, Bernd

    2007-01-01

    We compared the cost effectiveness of recent approaches [coronary angiography and calcium scoring using computed tomography (CT) and stress magnetic resonance imaging (MRI)] to the diagnosis of coronary artery disease (CAD) with those of the traditional diagnostic modalities [conventional angiography (CATH), exercise ECG, and stress echocardiography] using a decision tree model. For patients with a 10% to 50% pretest likelihood of coronary artery disease, non-invasive coronary angiography using CT was the most cost effective approach, with costs per correctly identified CAD patient of EUR4,435 (10% likelihood) to EUR1,469 (50% likelihood). Only for a pretest likelihood of 30% to 40% was calcium scoring using CT more cost effective than any of the traditional diagnostic modalities, while MRI was not cost effective for any pretest likelihood. At a pretest likelihood of 60%, CT coronary angiography and CATH were equally effective, while CATH was most cost effective for a pretest likelihood of at least 70%. In conclusion, up to a pretest likelihood for coronary artery disease of 50%, CT coronary angiography is the most cost-effective procedure, being superior to the other new modalities and the most commonly used traditional diagnostic modalities. With a very high likelihood for disease (above 60%), CATH is the most effective procedure from the perspective of society. (orig.)

  18. Appearance and impact of post-operative intracranial clips and coils on whole-brain CT angiography and perfusion

    International Nuclear Information System (INIS)

    Roach, Cayce J.; Russell, Cheryl L.; Hanson, Eric H.; Bluett, Brent; Orrison, William W.

    2012-01-01

    Background: To evaluate the effect of vascular clips and endovascular coils placed for intracranial aneurysms and arteriovenous malformations on whole-brain computed tomography (CT) angiography and perfusion. Methods: A 320-detector row dynamic volume CT system imaged 11 patients following surgical placement of vascular clips or endovascular coils. The extent of clip and coil subtraction by automated software was evaluated using CT digital subtraction angiography and CT perfusion. Impact on CT perfusion values by retained intracranial devices was compared to age- and gender-matched controls. Results: Clip and coil subtraction on CT angiography was graded as good in 8 and moderate in 3 cases. A residual neck and additional aneurysm were noted in 1 of 11 patients. Post-procedural axial slice level CT perfusion values decreased in reliability with increasing proximity to the metallic devices secondary to beam hardening. However, the intracranial devices did not affect axial slice level CTP values of cerebral blood volume, cerebral blood flow and mean transit time outside of the level of the device. Time to peak values was globally decreased outside of the immediate vascular intervention region. Conclusions: Advances in CT technology have provided clinically useful subtraction of intracranial clips and coils. While CT perfusion values were altered in device subtraction areas and within beam hardening artifact areas; they can provide valuable postoperative information on whole-brain hemodynamics. In selected cases, the combination of CT angiography and whole-brain CT perfusion can offer an alternative to conventional angiography that is a more invasive option.

  19. Cervical spinal cord injury during cerebral angiography with MRI confirmation: case report

    Energy Technology Data Exchange (ETDEWEB)

    Bejjani, G.K.; Rizkallah, R.G.; Tzortidis, F. [Department of Neurosurgery, George Washington University Medical Center, Washington, DC (United States); Mark, A.S. [Department of Neuroradiology, Washington Hospital Center, Washington, DC (United States)

    1998-01-01

    We report the first case of MRI-documented cervical spinal cord injury during cerebral angiography. A 54-year-old woman underwent an angiogram for subarachnoid hemorrhage. Her head was secured in a plastic head-holder. At the end of the procedure, she was found to have a left hemiparesis. MRI revealed high signal in the cervical spinal cord. The etiology may have been mechanical due to patient positioning, or toxic, from contrast medium injection in the vessels feeding the spinal cord, or a combination of both. (orig.) With 3 figs., 26 refs.

  20. Strain-encoded cardiac MRI as an adjunct for dobutamine stress testing: incremental value to conventional wall motion analysis.

    Science.gov (United States)

    Korosoglou, Grigorios; Lossnitzer, Dirk; Schellberg, Dieter; Lewien, Antje; Wochele, Angela; Schaeufele, Tim; Neizel, Mirja; Steen, Henning; Giannitsis, Evangelos; Katus, Hugo A; Osman, Nael F

    2009-03-01

    High-dose dobutamine stress MRI is safe and feasible for the diagnosis of coronary artery disease (CAD) in humans. However, the assessment of cine scans relies on the visual interpretation of regional wall motion, which is subjective. Recently, strain-encoded MRI (SENC) has been proposed for the direct color-coded visualization of myocardial strain. The purpose of our study was to compare the diagnostic value of SENC with that provided by conventional wall motion analysis for the detection of inducible ischemia during dobutamine stress MRI. Stress-induced ischemia was assessed by wall motion analysis and by SENC in 101 patients with suspected or known CAD and in 17 healthy volunteers who underwent dobutamine stress MRI in a clinical 1.5-T scanner. Quantitative coronary angiography deemed as the standard reference for the presence or absence of significant CAD (> or =50% diameter stenosis). On a coronary vessel level, SENC detected inducible ischemia in 86 of 101 versus 71 of 101 diseased coronary vessels (P or =50% stenosis (area under the curve, 0.96; SE, 0.01; 95% CI, 0.94 to 0.98; P<0.001). The direct color-coded visualization of strain on MR images is a useful adjunct for dobutamine stress MRI, which provides incremental value for the detection of CAD compared with conventional wall motion readings on cine images.

  1. Assessment Of Coronary Arterial Stents By Multislice-CT Angiography

    International Nuclear Information System (INIS)

    Maintz, D.; Fallenberg, E. M.; Heindel, W.; Fischbach, R.; Grude, M.

    2003-01-01

    Purpose: To assess patency and lumen visibility of coronary artery stents by multislice-CT angiography (MSCTA) in comparison with conventional coronary angiography as the standard of reference. Material and Methods: 47 stents of 13 different types were evaluated in 29 patients. MSCTA was performed on a 4-slice scanner with a standard coronary protocol (detector collimation 4 x 1 mm; table feed 1.5 mm/rotation, 400 mAs, 120 kV). Image evaluation was performed by two readers who were blinded to the reports from the catheter angiography. MIP reconstructions were evaluated for image quality on a 4-point scale (1 = poor, 4 = excellent) and stent patency (contrast distal to the stent as an indirect patency sign). Axial images and multiplanar reformations through the stents were used for assessment of stent lumen visibility (measurement of the visible stent lumen diameter) and detection of relevant in-stent stenosis (50%). Results: Image quality was fair to good on average (score 2.64 ± 1.0) and depended on the heart rate (heart rate 45-60: average score 3.2, heart rate 61-70: average score 2.8, heart rate >71: average score 1.4). Thirty-seven stents were correctly classified as patent, 1 was correctly classified as occluded and 9 stents were not assessable due to insufficient image quality because of triggering artifacts. Parts of the stent lumen could be visualized in 30 cases. On average, 20-40% of the stent lumen diameter was visible. Twenty-five stents were correctly classified as having no stenosis, 1 was falsely classified as stenosed, 1 was correctly classified as occluded. In 20 stents lumen visibility was not sufficient for stenosis evaluation. Conclusion: Although the stent lumen may be partly visualized in most stents, a reliable evaluation of in-stent stenoses does not seem practical by 4-slice MSCT. Nevertheless, for stent patency evaluation, MS-CTA might provide valuable clinical information. With submillimeter MSCT (e.g. 16-slice scanners) and more

  2. The role of CT angiography in the evaluation of pediatric renovascular hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Kurian, Jessica [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); The Children' s Hospital at Montefiore, Bronx, NY (United States); Epelman, Monica [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Nemours Children' s Hospital, Department of Radiology, Orlando, FL (United States); Darge, Kassa; Nijs, Els [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Meyers, Kevin [The Perelman School of Medicine, University of Pennsylvania, Division of Nephrology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Hellinger, Jeffrey C. [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); New York Cardiovascular Institute and Lenox Hill Radiology, New York, NY (United States)

    2013-04-15

    Historically, the evaluation of renovascular hypertension has been accomplished by US, renal scintigraphy and digital subtraction angiography. Based on its high accuracy reported in adults renal CT angiography (CTA) with pediatric-appropriate low radiation dose techniques has become an important tool in the workup of renovascular hypertension in children. Renal CTA has several advantages over more conventional imaging modalities, including rapid and non-invasive acquisition, high resolution and easy reproducibility. Additionally, in our experience high-quality renal CTA can be performed using low-dose radiation exposures and can be acquired without sedation in most instances. This article illustrates by examples the usefulness of renal CTA for diagnosis of childhood renovascular hypertension and provides an overview of renal CTA findings in the most common childhood renovascular diseases. (orig.)

  3. Routine evaluation ot arteriopathies of the lower extremities by digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Stacul, F; Pozzi-Mucelli, R; Predonzan, F; Magnaldi, S; Abbona, M; Pozzi-Mucelli, R S; Dalla Palma, L

    1985-11-01

    Intravenous digital subtraction angiography (DSA) was performed in 119 patients with lower extremity ischemia using a 14'' amplifier. Four injections of contrast medium were usually necessary for a complete evaluation of this vascular region. Images of good quality were obtained in most cases; movement artifacts and a faint opacification accounted for any poor results, which occured mainly under the knee. The technique of pixel shifting turned out to be very useful to remove movement artifacts. The 'measuring field' allowed us to minimize the problem of the inhomogeneous saturation of the amplifier. In 8% of the cases an intra-arterial DSA has been performed after an unsatisfactory intravenous examination. Conventional angiography appears to be no longer necessary.

  4. TOF MR angiography of cerebral arteriovenous malformations before and after radiotherapy

    International Nuclear Information System (INIS)

    Schlemmer, H.P.; Hess, T.; Debus, J.; Knopp, M.V.; Schad, L.R.; Engenhart, R.

    1994-01-01

    We studied whether 3D time-of-flight (TOF) MR angiography can be used for therapy planning and monitoring. MRI and TOF-MRA studies of 28 patients undergoing radiotherapy were evaluated. They were compared to conventional angiography to assess the MRA study. A correct identification of the arterial feeder and the nidus was possible in about 75% of the patients. In combination with the MRI study, an important 3D dataset for treatment planning could be obtained that includes therapeutically relevant information on the localization and spatial structure of the AVM as well as the adjacent brain tissue. As a noninvasive technique, close-meshed follow-up studies could be performed with MRA. (orig./MG) [de

  5. Myocardial bridging: evaluation with multislice computed tomography coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Barros, M.V.L. de; Rabelo, D.R.; Nunes, M.C.P.; Siqueira, M.H.A. [Mater Dei Hospital, Belo Horizonte, MG (Brazil)

    2012-04-15

    Myocardial bridging (MB) is defined as a segment of a major epicardial coronary artery that proceeds intramurally through the myocardium beneath the muscle bridge. Although MB is clinically silent in most cases, it has been associated with myocardial ischemia, myocardial infarction, arrhythmia, and sudden death. Conventional coronary angiography (CCA) is the gold standard for detection, but it is invasive and may not be sensitive enough to detect a thin bridge. Recently, multislice computed tomography coronary angiography (MCTCA) have made possible the clear detection of the entire running courses of coronary arteries and the MB itself. Objective: To evaluate the prevalence MB in patients suspect to coronary artery disease submitted to MCTCA and assessing the predictive value of this method in the midterm. Methods: 498 consecutive patients were examined by MCTCA for the diagnosis of coronary artery disease and followed for a mean follow-up of 17 months for the occurrence of cardiovascular events (death, hospitalization and / or revascularization myocardial). Results: The mean age of patients was 58.4 ± 12.5 years old, 74.3% male. Among the patients, 6,02% (30 patients) showed MB. The major indications were angina pectoris in 45,8% and positive stress testing in 33,3%. 62,5% showed absent atherosclerotic disease and only 1 patient showed moderade descending anterior stenosis. During the follow-up none patient showed hard events. Conclusion: Patients with MB could present with angina pectoris and positive stress testing and showed midterm excellent prognosis. MCTCA is an alternative noninvasive imaging tool that allows for easy and accurate evaluation of MB.

  6. High-resolution coronary MR angiography for evaluation of patients with anomalous coronary arteries: visualization of the intramural segment

    Energy Technology Data Exchange (ETDEWEB)

    Biko, David M. [UCSF Benioff Children' s Hospital Oakland, Department of Diagnostic Imaging, Oakland, CA (United States); The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Chung, Claudia; Chung, Taylor [UCSF Benioff Children' s Hospital Oakland, Department of Diagnostic Imaging, Oakland, CA (United States); Hitt, David M. [Philips Healthcare, Cleveland, OH (United States); Kurio, Gregory [UCSF Benioff Children' s Hospital Oakland, Department of Cardiology, Oakland, CA (United States); Reinhartz, Olaf [UCSF Benioff Children' s Hospital Oakland, Department of Cardiac Surgery, Oakland, CA (United States)

    2015-08-15

    Anomalous origin of the coronary artery from the contralateral coronary sinus is a rare coronary anomaly associated with sudden death. The inter-arterial course is most closely associated with sudden death, but it has been suggested that the presence of an intramural segment of a right anomalous coronary is associated with more symptoms and therefore may be an important criterion for intervention in these patients. To demonstrate that MR angiography can accurately determine the presence or absence of an intramural segment in an anomalous coronary artery. All studies of children who underwent MR angiography for the evaluation of an anomalous coronary artery were retrospectively reviewed by two pediatric radiologists in consensus. Criteria for an intramural anomalous coronary artery were the presence of a small or slit-like ostium and the relative smaller size of the proximal intramural portion of the coronary artery in relation to the more distal epicardial coronary artery. The anomalous coronary artery was classified as not intramural if these two findings were absent. These findings were correlated with operative reports confirming the presence or absence of an intramural segment. Twelve patients (86%) met MR angiography criteria for the presence of an intramural course. Only 2 patients (14%) met MR angiography criteria for a non-intramural course. When correlating with intraoperative findings, MR angiography was successful in distinguishing between intramural and non-intramural anomalous coronary arteries in all cases (P = 0.01). MR angiography may be able to reliably identify the intramural segment of an anomalous coronary artery in older children using the imaging criteria of a small or slit-like ostium and relative decrease in size of the proximal portion of the anomalous coronary artery compared to the distal portion of the anomalous coronary artery. Determining the presence of the intramural segment may help with surgical planning and may be an important

  7. Imaging of peripheral arteries by 16-slice computed tomography angiography: a valuable tool

    International Nuclear Information System (INIS)

    Mishra, A.; Ehtuish, Ehtuish F.

    2007-01-01

    To evaluate the efficacy of multidetector (16-row) computed tomography (MDCT) in imaging the upper and lower limb arterial tree in trauma and peripheral vascular disease. Thirty three patients underwent multislice computed tomography angiography (MSCTA) of the upper or the lower limb on multislice (16-slice) CT scanner between November 2004 and July 2005 in the Department of Radiology, National Organ Transplant Center, Tripoli, Libya. The findings were retrospectively compared with the surgical outcome in cases of trauma with suspected arterial injuries; or color Doppler correlation was obtained, for patients of peripheral vascular disease. Multislice computed tomography angiography allows a comprehensive diagnostic work-up in all trauma cases with suspected arterial injuries. In 23 cases of peripheral vascular diseases, MSCTA adequately demonstrated the presence of any stenosis or occlusion, its degree and extent, the presence of collaterals and distal reformation if any; the presence of plaques. Our experience of computed tomography angiography with 16-row MDCT scanner has clearly demonstrated its efficacy as a promising, new, fast, accurate, safe and non-invasive imaging modality of choice in cases of trauma with suspected arterial injuries; and as a useful screening modality in cases of peripheral vascular disease for diagnosis and for grading. (author)

  8. Radiological management of blunt polytrauma with computed tomography and angiography: an integrated approach

    Energy Technology Data Exchange (ETDEWEB)

    Kurdziel, J.C.; Dondelinger, R.F.; Hemmer, M.

    1987-01-01

    107 polytraumatized patients, who had experienced blunt trauma have been worked up at admission with computed tomography of the thorax, abdomen and pelvis following computed tomography study of the brain: significant lesions were revealed in 98 (90%) patients. 79 (74%) patients showed trauma to the thorax, in 69 (64%) patients abdominal or pelvic trauma was evidenced. No false positive diagnosis was established. 5 traumatic findings were missed. Emergency angiography was indicated in 3 (3%) patients, following computed tomography examination. 3 other trauma patients were submitted directly to angiography without computed tomography examination during the time period this study was completed. Embolization was carried out in 5/6 patients. No thoracotomy was needed. 13 (12%) patients underwent laparotomy following computed tomography. Overall mortality during hospital stay was 14% (15/107). No patient died from visceral bleeding. Conservative management of blunt polytrauma patients can be advocated in almost 90% of visceral lesions. Computed tomography coupled with angiography and embolization represent an adequate integrated approach to the management of blunt polytrauma patients.

  9. Cerebral angiography with prospective ECG triggering preliminary study of dual-source CT

    International Nuclear Information System (INIS)

    Xue Yuejun; Qian Nong; Shao Yanhui; Pan Changjie; Rong Weiliang; Xu Yiqun

    2012-01-01

    Objective: To study the image quality and radiation dose in dual-source CT cerebral angiography with prospective ECG-triggered sequence mode (step-and-shoot, SAS). Methods: A total of forty-three patients with clinically suspected cerebral vascular disease underwent cerebral CT angiography with prospective ECG-triggering (step-and-shoot, SAS). Data acquisition was at 60% R-R interval of the ECG presentation mode. The post-processing included maximum intensity projection (MIP), multiplanar reformation (MPR) and volume rendering (VR). The CTA image quality, radiation dose and rates of excellent images were evaluated. Results: The CTA image quality score was 4.72 ± 0.50 and 97.7% (42/43) patients had excellent CTA images. The average effective dose of SAS-CTA was (0.22 ± 0.01)mSv, which was lower by 76.31% than that of DE-CTA. Conclusions: Prospective ECG-triggering sequence could be used in cerebral angiography with a significant reduction in radiation dose and diagnostic image quality. (authors)

  10. Prognostic value and limitations of exercise radionuclide angiography in medically treated coronary artery disease

    International Nuclear Information System (INIS)

    Taliercio, C.P.; Clements, I.P.; Zinsmeister, A.R.; Gibbons, R.J.

    1988-01-01

    We investigated whether exercise radionuclide angiography provides prognostic information in addition to that identified by resting left ventricular function and coronary anatomy in patients with medically treated coronary artery disease. Clinical follow-up (median, 21.7 months) was obtained in 424 medically treated patients who underwent exercise radionuclide angiography and coronary angiography. The mean age of the study population was 58 years, and 67% were men. Cardiac death occurred in 16 patients, nonfatal myocardial infarction in 16, and nonfatal out-of-hospital cardiac arrest in 1. Univariate analysis showed that multiple variables were associated with future cardiac events, including number of diseased vessels, exercise and rest radionuclide ejection fraction, history of myocardial infarction, exercise and rest left ventricular end-systolic and end-diastolic volume indices, peak exercise workload, age, abnormal resting electrocardiogram, and peak exercise ST-segment depression. Only three variables were independently associated with cardiac events on follow-up: number of diseased vessels, radionuclide ejection fraction at rest, and age. In patients with three-vessel disease and a resting radionuclide ejection fraction of more than 40%, a subgroup with higher risk could not be identified on the basis of exercise radionuclide response

  11. Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.

    Science.gov (United States)

    Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P

    2005-12-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.

  12. Radiological management of blunt polytrauma with computed tomography and angiography: an integrated approach

    International Nuclear Information System (INIS)

    Kurdziel, J.C.; Dondelinger, R.F.; Hemmer, M.

    1987-01-01

    107 polytraumatized patients, who had experienced blunt trauma have been worked up at admission with computed tomography of the thorax, abdomen and pelvis following computed tomography study of the brain: significant lesions were revealed in 98 (90%) patients. 79 (74%) patients showed trauma to the thorax, in 69 (64%) patients abdominal or pelvic trauma was evidenced. No false positive diagnosis was established. 5 traumatic findings were missed. Emergency angiography was indicated in 3 (3%) patients, following computed tomography examination. 3 other trauma patients were submitted directly to angiography without computed tomography examination during the time period this study was completed. Embolization was carried out in 5/6 patients. No thoracotomy was needed. 13 (12%) patients underwent laparotomy following computed tomography. Overall mortality during hospital stay was 14% (15/107). No patient died from visceral bleeding. Conservative management of blunt polytrauma patients can be advocated in almost 90% of visceral lesions. Computed tomography coupled with angiography and embolization represent an adequate integrated approach to the management of blunt polytrauma patients

  13. Optical coherence tomography angiography retinal vascular network assessment in multiple sclerosis.

    Science.gov (United States)

    Lanzillo, Roberta; Cennamo, Gilda; Criscuolo, Chiara; Carotenuto, Antonio; Velotti, Nunzio; Sparnelli, Federica; Cianflone, Alessandra; Moccia, Marcello; Brescia Morra, Vincenzo

    2017-09-01

    Optical coherence tomography (OCT) angiography is a new method to assess the density of the vascular networks. Vascular abnormalities are considered involved in multiple sclerosis (MS) pathology. To assess the presence of vascular abnormalities in MS and to evaluate their correlation to disease features. A total of 50 MS patients with and without history of optic neuritis (ON) and 46 healthy subjects were included. All underwent spectral domain (SD)-OCT and OCT angiography. Clinical history, Expanded Disability Status Scale (EDSS), Multiple Sclerosis Severity Score (MSSS) and disease duration were collected. Angio-OCT showed a vessel density reduction in eyes of MS patients when compared to controls. A statistically significant reduction in all SD-OCT and OCT angiography parameters was noticed both in eyes with and without ON when compared with control eyes. We found an inverse correlation between SD-OCT parameters and MSSS ( p = 0.003) and between vessel density parameters and EDSS ( p = 0.007). We report a vessel density reduction in retina of MS patients. We highlight the clinical correlation between vessel density and EDSS, suggesting that angio-OCT could be a good marker of disease and of disability in MS.

  14. CAPILLARY NETWORK ALTERATIONS IN X-LINKED RETINOSCHISIS IMAGED ON OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    Science.gov (United States)

    Romano, Francesco; Arrigo, Alessandro; Chʼng, Soon Wai; Battaglia Parodi, Maurizio; Manitto, Maria Pia; Martina, Elisabetta; Bandello, Francesco; Stanga, Paulo E

    2018-06-05

    To assess foveal and parafoveal vasculature at the superficial capillary plexus, deep capillary plexus, and choriocapillaris of patients with X-linked retinoschisis by means of optical coherence tomography angiography. Six patients with X-linked retinoschisis (12 eyes) and seven healthy controls (14 eyes) were recruited and underwent complete ophthalmologic examination, including best-corrected visual acuity, dilated fundoscopy, and 3 × 3-mm optical coherence tomography angiography macular scans (DRI OCT Triton; Topcon Corp). After segmentation and quality review, optical coherence tomography angiography slabs were imported into ImageJ 1.50 (NIH; Bethesda) and digitally binarized. Quantification of vessel density was performed after foveal avascular zone area measurement and exclusion. Patients were additionally divided into "responders" and "nonresponders" to dorzolamide therapy. Foveal avascular zone area resulted markedly enlarged at the deep capillary plexus (P < 0.001), particularly in nonresponders. Moreover, patients disclosed a significant deep capillary plexus rarefaction, when compared with controls (P: 0.04); however, a subanalysis revealed that this damage was limited to the fovea (P: 0.006). Finally, the enlargement of foveal avascular zone area positively correlated with a decline in best-corrected visual acuity (P: 0.01). Prominent foveal vascular impairment is detectable in the deep capillary plexus of patients with X-linked retinoschisis. Our results correlate with functional outcomes, suggesting a possible vascular role in X-linked retinoschisis clinical manifestations.

  15. Inflammatory aortic arch syndrome: contrast-enhanced, three-dimensional MR - angiography in stenotic lesions

    International Nuclear Information System (INIS)

    Both, M.; Mueller-Huelsbeck, S.; Biederer, J.; Heller, M.; Reuter, M.

    2004-01-01

    Purpose: To determine the value of contrast-enhanced, three-dimensional MR angiography for the evaluation of stenotic and occlusive vascular lesions in inflammatory aortic arch syndrome. Materials and Methods: 14 patients with inflammatory aortic arch syndrome (giant cell arteritis: n = 8, Takayasu arteritis: n = 4, ankylosing spondylitis: n = 1 sarcoidosis: n = 1) underwent MR angiography of the aortic arch and the supra-aortic vessels (n = 15,2 patients were examined twice) and of the abdominal aorta (n = 2). MRA was performed using a 3D-FLASH sequence (TR/TE 4.6/1.8 ms, flip angle 30 ) on a 1.5T system. MRA imaging was compared with the findings of DSA, which served as gold standard. Results: In a total of 467 examined vascular territories, DSA revealed 50 stenoses and 35 occlusions. All lesions were detected by MRA. In 23 segments, the degree of stenosis was overestimated by MRA. Sensitivity and specificity of MRA were 100% and 94,3%, positive and negative predictive values were 73.6 and 100%, and the accuracy was 95,1%. Conclusions: Despite a tendency to overestimate stenoses, contrast-enhanced three-dimensional MR angiography is a valid, non-invasive technique in the assessment of inflammatory aortic arch syndrome. (orig.) [de

  16. Algorithms for the Analysis of 3D Magnetic Resonance Angiography Images

    International Nuclear Information System (INIS)

    Tizon, Xavier

    2004-01-01

    Atherosclerosis is a disease of the arterial wall, progressively impairing blood flow as it spreads throughout the body. The heart attacks and strokes that result of this condition cause more deaths than cancer in industrial countries. Angiography refers to the group of imaging techniques used through the diagnosis, treatment planning and follow-up of atherosclerosis. In recent years, Magnetic Resonance Angiography (MRA) has shown promising abilities to supplant conventional, invasive, X-ray-based angiography. In order to fully benefit from this modality, there is a need for more objective and reproducible methods. This thesis shows, in two applications, how computerized image analysis can help define and implement these methods. First, by using segmentation to improve visualization of blood-pool contrast enhanced (CE)-MRA, with an additional application in coronary Computerized Tomographic Angiography. We show that, using a limited amount of user interaction and an algorithmic framework borrowed from graph theory and fuzzy logic theory, we can simplify the display of complex 3D structures like vessels. Second, by proposing a methodology to analyze the geometry of arteries in whole-body CE-MRA. The vessel centreline is extracted, and geometrical properties of this 3D curve are measured, to improve interpretation of the angiograms. It represents a more global approach than the conventional evaluation of atherosclerosis, as a first step towards screening for vascular diseases. We have developed the methods presented in this thesis with clinical practice in mind. However, they have the potential to be useful to other applications of computerized image analysis

  17. Evaluation of the applicability of territorial arterial spin labeling in meningiomas for presurgical assessments compared with 3-dimensional time-of-flight magnetic resonance angiography

    International Nuclear Information System (INIS)

    Lu, Yiping; Wen, Jianbo; Geng, Daoying; Yin, Bo; Luan, Shihai; Liu, Li; Xiong, Ji; Qu, Jianxun

    2017-01-01

    To prospectively evaluate the application of territorial arterial spin labelling (t-ASL) in comparison with unenhanced three-dimensional time-of-flight magnetic resonance angiography (3D-TOF-MRA) in the identification of the feeding vasculature of meningiomas. Thirty consecutive patients with suspected meningiomas underwent conventional MR imaging, unenhanced 3D-TOF-MRA and t-ASL scanning. Four experienced neuro-radiologists assessed the feeding vessels with different techniques separately. For the identification of the origin of the feeding arteries on t-ASL, the inter-observer agreement was excellent (κ = 0.913), while the inter-observer agreement of 3D-TOF-MRA was good (κ = 0.653). The inter-modality agreement between t-ASL and 3D-TOF-MRA for the feeding arteries was moderate (κ = 0.514). All 8 patients with motor or sensory disorders proved to have meningiomas supplied completely or partially by the internal carotid arteries, while all 14 patients with meningiomas supplied by the external carotid arteries or basilar arteries didn't show any symptoms concerning motor or sensory disorders (p = 0.003). T-ASL could complement unenhanced 3D-TOF-MRA and increase accuracy in the identification of the supplying arteries of meningiomas in a safe, intuitive, non-radioactive manner. The information about feeding arteries was potentially related to patients' symptoms and pathology, making it more crucial for neurosurgeons in planning surgery as well as evaluating prognosis. (orig.)

  18. Evaluation of the applicability of territorial arterial spin labeling in meningiomas for presurgical assessments compared with 3-dimensional time-of-flight magnetic resonance angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Yiping; Wen, Jianbo; Geng, Daoying; Yin, Bo [Fudan University, Department of Radiology, Huashan Hospital, Shanghai (China); Luan, Shihai [Fudan University, Department of Neurosurgery, Huashan Hospital, Shanghai (China); Liu, Li [Fudan University, Department of Radiology, Shanghai Cancer Center, Shanghai (China); Xiong, Ji [Fudan University, Department of Pathology, Huashan Hospital, Shanghai (China); Qu, Jianxun [GE Healthcare, Department of MR Research, Shanghai (China)

    2017-10-15

    To prospectively evaluate the application of territorial arterial spin labelling (t-ASL) in comparison with unenhanced three-dimensional time-of-flight magnetic resonance angiography (3D-TOF-MRA) in the identification of the feeding vasculature of meningiomas. Thirty consecutive patients with suspected meningiomas underwent conventional MR imaging, unenhanced 3D-TOF-MRA and t-ASL scanning. Four experienced neuro-radiologists assessed the feeding vessels with different techniques separately. For the identification of the origin of the feeding arteries on t-ASL, the inter-observer agreement was excellent (κ = 0.913), while the inter-observer agreement of 3D-TOF-MRA was good (κ = 0.653). The inter-modality agreement between t-ASL and 3D-TOF-MRA for the feeding arteries was moderate (κ = 0.514). All 8 patients with motor or sensory disorders proved to have meningiomas supplied completely or partially by the internal carotid arteries, while all 14 patients with meningiomas supplied by the external carotid arteries or basilar arteries didn't show any symptoms concerning motor or sensory disorders (p = 0.003). T-ASL could complement unenhanced 3D-TOF-MRA and increase accuracy in the identification of the supplying arteries of meningiomas in a safe, intuitive, non-radioactive manner. The information about feeding arteries was potentially related to patients' symptoms and pathology, making it more crucial for neurosurgeons in planning surgery as well as evaluating prognosis. (orig.)

  19. Hybrid ECG-gated versus non-gated 512-slice CT angiography of the aorta and coronary artery: image quality and effect of a motion correction algorithm.

    Science.gov (United States)

    Lee, Ji Won; Kim, Chang Won; Lee, Geewon; Lee, Han Cheol; Kim, Sang-Pil; Choi, Bum Sung; Jeong, Yeon Joo

    2018-02-01

    Background Using the hybrid electrocardiogram (ECG)-gated computed tomography (CT) technique, assessment of entire aorta, coronary arteries, and aortic valve can be possible using single-bolus contrast administration within a single acquisition. Purpose To compare the image quality of hybrid ECG-gated and non-gated CT angiography of the aorta and evaluate the effect of a motion correction algorithm (MCA) on coronary artery image quality in a hybrid ECG-gated aorta CT group. Material and Methods In total, 104 patients (76 men; mean age = 65.8 years) prospectively randomized into two groups (Group 1 = hybrid ECG-gated CT; Group 2 = non-gated CT) underwent wide-detector array aorta CT. Image quality, assessed using a four-point scale, was compared between the groups. Coronary artery image quality was compared between the conventional reconstruction and motion correction reconstruction subgroups in Group 1. Results Group 1 showed significant advantages over Group 2 in aortic wall, cardiac chamber, aortic valve, coronary ostia, and main coronary arteries image quality (all P ECG-gated CT significantly improved the heart and aortic wall image quality and the MCA can further improve the image quality and interpretability of coronary arteries.

  20. T2*-weighted MR angiography substantially increases the detection of hemorrhage in the wall of brain abscess: implications in clinical interpretation

    International Nuclear Information System (INIS)

    Gupta, Rakesh Kumar; Tomar, Vaishali; Awasthi, Rishi; Yadav, Abhishek; Husain, Nuzhat; Bharadwaj, Vikas; Ojha, Bal K.; Behari, Sanjay; Prasad, Kashi N.; Singh Rathore, Ram Kishore

    2012-01-01

    The purpose of the present study was to identify the true prevalence of hemorrhage in the abscess using T2*-weighted angiography (SWAN) imaging and to study its influence on diffusion tensor imaging (DTI) metrics. Fifteen patients of brain abscess underwent conventional, SWAN, and DT imaging on a 3-T MRI followed by its confirmation with histology. DTI metrics were quantified by region-of-interest analysis on hemorrhagic and non-hemorrhagic regions of the abscess wall. Prussian blue staining was performed on excised abscess walls to confirm hemorrhage on histology. Eleven of 15 patients showed evidence of hemorrhage on both Prussian blue staining as well as SWAN imaging. Fractional anisotropy (FA) and linear anisotropy (CL) values were significantly higher, while spherical anisotropy was significantly lower in hemorrhagic compared to non-hemorrhagic regions of the abscess wall. Hemorrhage in the abscess wall is a common feature and may not always indicate neoplasm. The presence of intracellular iron in addition to concentrically laid collagen fibers may have synergistic effect on FA and CL values in the abscess wall. Inclusion of SWAN to MRI protocol will define the true prevalence of hemorrhage in brain abscess. (orig.)

  1. Combined anatomical and functional imaging using coronary CT angiography and myocardial perfusion SPECT in symptomatic adults with abnormal origin of a coronary artery.

    Science.gov (United States)

    Uebleis, C; Groebner, M; von Ziegler, F; Becker, A; Rischpler, C; Tegtmeyer, R; Becker, C; Lehner, S; Haug, A R; Cumming, P; Bartenstein, P; Franz, W M; Hacker, M

    2012-10-01

    There has been a lack of standardized workup guidelines for patients with congenital abnormal origin of a coronary artery from the opposite sinus (ACAOS). We aimed to evaluate the use of cardiac hybrid imaging using multi-detector row CT (MDCT) for coronary CT angiography (Coronary CTA) and stress-rest myocardial perfusion SPECT (MPS) for comprehensive diagnosis of symptomatic adult patients with ACAOS. Seventeen symptomatic patients (12 men; 54 ± 13 years) presenting with ACAOS underwent coronary CTA and MPS. Imaging data were analyzed by conventional means, and with additional use of 3D image fusion to allocate stress induced perfusion defects (PD) to their supplying coronary arteries. An anomalous RCA arose from the left anterior sinus in eight patients, an abnormal origin from the right sinus was detected in nine patients (5 left coronary arteries, LCA and 4 LCx). Five of the 17 patients (29%) demonstrated a reversible PD in MPS. There was no correlation between the anatomical variants of ACAOS and the presence of myocardial ischemia. Image fusion enabled the allocation of reversible PD to the anomalous vessel in three patients (two cases in the RCA and the other in the LCA territory); PD in two patients were allocated to the territory of artery giving rise to the anomalies, rather than the anomalies themselves. In a small cohort of adult symptomatic patients with ACAOS anomaly there was no relation found between the specific anatomical variant and the appearance of stress induced myocardial ischemia using cardiac hybrid imaging.

  2. [A Distal Bile Duct Carcinoma Patient Who Underwent Surgical Resection for Liver Metastasis].

    Science.gov (United States)

    Komiyama, Sosuke; Izumiya, Yasuhito; Kimura, Yu; Nakashima, Shingo; Kin, Syuichi; Kawakami, Sadao

    2018-03-01

    A 70-year-old man with distal bile duct carcinoma underwent a subtotal stomach-preserving pancreaticoduodenectomy without adjuvant chemotherapy. One and a half years after the surgery, elevated levels of serum SPan-1(38.1 U/mL)were observed and CT scans demonstrated a solitary metastasis, 25mm in size, in segment 8 of the liver. The patient received 2 courses of gemcitabine-cisplatin combination chemotherapy. No new lesions were detected after chemotherapy and the patient underwent a partial liver resection of segment 8. The pathological examination revealed a metachronous distant metastasis originating from the bile duct carcinoma. Subsequently, the patient received S-1 adjuvant chemotherapy for 6 months. Following completion of all therapies, the patient survived without tumor recurrence for 3 years and 10 months after the initial operation. Thus, surgical interventions might be effective in improving prognosis among selected patients with postoperative liver metastasis of bile duct carcinoma.

  3. Dysphagia among Adult Patients who Underwent Surgery for Esophageal Atresia at Birth

    Directory of Open Access Journals (Sweden)

    Valérie Huynh-Trudeau

    2015-01-01

    Full Text Available BACKGROUND: Clinical experiences of adults who underwent surgery for esophageal atresia at birth is limited. There is some evidence that suggests considerable long-term morbidity, partly because of dysphagia, which has been reported in up to 85% of adult patients who undergo surgery for esophageal atresia. The authors hypothesized that dysphagia in this population is caused by dysmotility and/or anatomical anomalies.

  4. Effect of using pump on postoperative pleural effusion in the patients that underwent CABG

    Directory of Open Access Journals (Sweden)

    Mehmet Özülkü

    2015-08-01

    Full Text Available Abstract Objective: The present study investigated effect of using pump on postoperative pleural effusion in patients who underwent coronary artery bypass grafting. Methods: A total of 256 patients who underwent isolated coronary artery bypass grafting surgery in the Cardiovascular Surgery clinic were enrolled in the study. Jostra-Cobe (Model 043213 105, VLC 865, Sweden heart-lung machine was used in on-pump coronary artery bypass grafting. Off-pump coronary artery bypass grafting was performed using Octopus and Starfish. Proximal anastomoses to the aorta in both on-pump and off-pump techniques were performed by side clamps. The patients were discharged from the hospital between postoperative day 6 and day 11. Results: The incidence of postoperative right pleural effusion and bilateral pleural effusion was found to be higher as a count in Group 1 (on-pump as compared to Group 2 (off-pump. But the difference was not statistically significant [P>0.05 for right pleural effusion (P=0.893, P>0.05 for bilateral pleural effusion (P=0.780]. Left pleural effusion was encountered to be lower in Group 2 (off-pump. The difference was found to be statistically significant (P<0.05, P=0.006. Conclusion: Under the light of these results, it can be said that left pleural effusion is less prevalent in the patients that underwent off-pump coronary artery bypass grafting when compared to the patients that underwent on-pump coronary artery bypass grafting.

  5. Incidence of Bradycardia and Outcomes of Patients Who Underwent Orbital Atherectomy Without a Temporary Pacemaker.

    Science.gov (United States)

    Lee, Michael S; Nguyen, Heajung; Shlofmitz, Richard

    2017-02-01

    We analyzed the incidence of bradycardia and the safety of patients with severely calcified coronary lesions who underwent orbital atherectomy without the insertion of a temporary pacemaker. The presence of severely calcified coronary lesions can increase the complexity of percutaneous coronary intervention due to the difficulty in advancing and optimally expanding the stent. High-pressure inflations to predilate calcified lesions may cause angiographic complications like perforation and dissection. Suboptimal stent expansion is associated with stent thrombosis and restenosis. Orbital atherectomy safely and effectively modifies calcified plaque to facilitate optimal stent expansion. The incidence of bradycardia in orbital atherectomy is unknown. Fifty consecutive patients underwent orbital atherectomy from February 2014 to September 2016 at our institution, none of whom underwent insertion of a temporary pacemaker. The final analysis included 47 patients in this retrospective study as 3 patients were excluded because of permanent pacemaker implantation. The primary endpoint was significant bradycardia, defined as bradycardia requiring emergent pacemaker placement or a heart rate pacemaker appears to be safe.

  6. Comparison of Voice Quality Between Patients Who Underwent Inferior Turbinoplasty or Radiofrequency Cauterization.

    Science.gov (United States)

    Göker, Ayşe Enise; Aydoğdu, İmran; Saltürk, Ziya; Berkiten, Güler; Atar, Yavuz; Kumral, Tolgar Lütfi; Uyar, Yavuz

    2017-01-01

    The aim of this study was to analyze and compare the vocal quality in patients who underwent either submucosal turbinectomy or radiofrequency cauterization. In this study, we enrolled 60 patients diagnosed with inferior concha hypertrophy. These patients were divided into two groups by using computer program "Research Randomizer." Of the 60 patients, 30 underwent submucosal inferior turbinoplasty and 30 underwent radiofrequency cauterization. The control group was composed of 30 healthy adults with no nasal or upper aerodigestive system pathology. The patients were checked at weeks 1, 2, and 4. Voice records were taken before the procedure and at week 4 postprocedure. The mean age of patients in the inferior turbinoplasty group was 29.4 years (range: 19-42 years); in the radiofrequency group, it was 30.30 years (range: 18-50 years). There was no statistical difference in age between groups. In the inferior turbinoplasty group, there were 16 male and 14 female patients, and in the radiofrequency group, there were 13 male and 17 female patients. There was no significant difference in the number of males and females between groups. Voice professionals, especially singers, actors, and actresses, should be informed about possible voice changes before undergoing endonasal surgery because these individuals are more sensitive to changes in resonance organs. We believe that voice quality should be regarded as a highly important parameter when measuring the success of endonasal surgery. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  7. Evolution of elderly patients who underwent cardiac surgery with cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Alain Moré Duarte

    2016-01-01

    Full Text Available Introduction: There is a steady increase in the number of elderly patients with severe cardiovascular diseases who require a surgical procedure to recover some quality of life that allows them a socially meaningful existence, despite the risks.Objectives: To analyze the behavior of elderly patients who underwent cardiac surgery with cardiopulmonary bypass.Method: A descriptive, retrospective, cross-sectional study was conducted with patients over 65 years of age who underwent surgery at the Cardiocentro Ernesto Che Guevara, in Santa Clara, from January 2013 to March 2014.Results: In the study, 73.1% of patients were men; and there was a predominance of subjects between 65 and 70 years of age, accounting for 67.3%. Coronary artery bypass graft was the most prevalent type of surgery and had the longest cardiopulmonary bypass times. Hypertension was present in 98.1% of patients. The most frequent postoperative complications were renal dysfunction and severe low cardiac output, with 44.2% and 34.6% respectively.Conclusions: There was a predominance of men, the age group of 65 to 70 years, hypertension, and patients who underwent coronary artery bypass graft with prolonged cardiopulmonary bypass. Renal dysfunction was the most frequent complication.

  8. Angiography in the region of the foot

    Energy Technology Data Exchange (ETDEWEB)

    Zeitler, E.

    1984-06-01

    It is reported on technique, incidence and findings of angiography of the foot which provided magnifying angiography and non-ionic contrast media are used, is especially qualified for the differentiation of diabetic and non-diabetic angiopathies as well as for the identification of peripherical embolizations and digital arterial occlusions at thrombocytosis or polycythemia. The arteries of the foot represent the peripherical outflow at peripherical reconstructive performances at the lower leg and have to be studied prior to such reconstructive surgical interventions. The different localization of arterial obliterations and changes of the walls in diabetics of stage I-IV according to Fontaine shows the particularly large number of vascular-pathological findings in arteries of the lower leg and foot in diabetics with arterial occlusive diseases of stage III and IV. Therefore, the unfavourable prognoses of arterial occlusive diseases in diabetics have also to be made for peripherical arterial obliterations of the foot and lower leg.

  9. Angiography in the region of the foot

    International Nuclear Information System (INIS)

    Zeitler, E.

    1984-01-01

    It is reported on technique, incidence and findings of angiography of the foot which provided magnifying angiography and non-ionic contrast media are used, is especially qualified for the differentiation of diabetic and non-diabetic angiopathies as well as for the identification of peripherical embolizations and digital arterial occlusions at thrombocytosis or polycythemia. The arteries of the foot represent the peripherical outflow at peripherical reconstructive performances at the lower leg and have to be studied prior to such reconstructive surgical interventions. The different localization of arterial obliterations and changes of the walls in diabetics of stage I-IV according to Fontaine shows the particularly large number of vascular-pathological findings in arteries of the lower leg and foot in diabetics with arterial occlusive diseases of stage III and IV. Therefore, the unfavourable prognoses of arterial occlusive diseases in diabetics have also to be made for peripherical arterial obliterations of the foot and lower leg. (orig.) [de

  10. Prevalence of non-cardiovascular findings on CT angiography in children with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Malik, Archana [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); St. Christopher' s Hospital for Children, Department of Radiology, Philadelphia, PA (United States); Hellinger, Jeffrey C. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); New York Cardiovascular Institute at Lenox Hill Radiology, New York, NY (United States); Servaes, Sabah; Keller, Marc S. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Schwartz, Mathew C. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Levine Children' s Hospital, Sanger Heart and Vascular Institute, Charlotte, NC (United States); Epelman, Monica [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Nemours Children' s Health System/Nemours Children' s Hospital, Department of Medical Imaging/Radiology, Orlando, FL (United States)

    2017-03-15

    CT angiography is gaining broader acceptance in the evaluation of children with known or suspected congenital heart disease. These studies include non-cardiovascular structures such as the mediastinum, lung parenchyma and upper abdominal organs. It is important to inspect all these structures for potential abnormalities that might be clinically important and, in some cases, may impact care plans. To determine the prevalence of non-cardiovascular findings in CT angiography of children with congenital heart disease. During 28 months, 300 consecutive children (170 males; mean age: 7.1 years, age range: 6 h-26 years), referred from a tertiary pediatric cardiology center, underwent clinically indicated CT angiography to evaluate known or suspected congenital heart disease. Slightly more than half (n = 169) of the patients were postoperative or post-intervention. Examinations were retrospectively reviewed, and non-cardiovascular findings were recorded and tabulated by organ system, congenital heart disease and operative procedure in conjunction with outcomes from medical charts. Non-cardiovascular findings were identified in 83% (n = 250 / 300) of the studies for a total of 857 findings. In 221 patients (n = 73.7% of 300) a total of 813 non-cardiovascular findings were clinically significant, while in 9.7% (n = 29 / 300) of patients, 5.1% (n = 44 / 857) of the findings were nonsignificant. In 38.3% (n = 115 / 300) of patients with significant non-cardiovascular pathology, the findings were unexpected and directly impacted patient care plans. Commonly involved organs with non-cardiovascular findings were the lungs with 280 non-cardiovascular findings in 176 / 300 (58.7%) of patients, the airway with 139 non-cardiovascular findings in 103 / 300 (34.3%) of patients and the liver with 108 non-cardiovascular findings in 72 / 300 (24.0%) of patients. Syndromic associations were noted in 22% (n = 66 / 300) of the patients. Non-cardiovascular findings are common in children with

  11. Prevalence of non-cardiovascular findings on CT angiography in children with congenital heart disease

    International Nuclear Information System (INIS)

    Malik, Archana; Hellinger, Jeffrey C.; Servaes, Sabah; Keller, Marc S.; Schwartz, Mathew C.; Epelman, Monica

    2017-01-01

    CT angiography is gaining broader acceptance in the evaluation of children with known or suspected congenital heart disease. These studies include non-cardiovascular structures such as the mediastinum, lung parenchyma and upper abdominal organs. It is important to inspect all these structures for potential abnormalities that might be clinically important and, in some cases, may impact care plans. To determine the prevalence of non-cardiovascular findings in CT angiography of children with congenital heart disease. During 28 months, 300 consecutive children (170 males; mean age: 7.1 years, age range: 6 h-26 years), referred from a tertiary pediatric cardiology center, underwent clinically indicated CT angiography to evaluate known or suspected congenital heart disease. Slightly more than half (n = 169) of the patients were postoperative or post-intervention. Examinations were retrospectively reviewed, and non-cardiovascular findings were recorded and tabulated by organ system, congenital heart disease and operative procedure in conjunction with outcomes from medical charts. Non-cardiovascular findings were identified in 83% (n = 250 / 300) of the studies for a total of 857 findings. In 221 patients (n = 73.7% of 300) a total of 813 non-cardiovascular findings were clinically significant, while in 9.7% (n = 29 / 300) of patients, 5.1% (n = 44 / 857) of the findings were nonsignificant. In 38.3% (n = 115 / 300) of patients with significant non-cardiovascular pathology, the findings were unexpected and directly impacted patient care plans. Commonly involved organs with non-cardiovascular findings were the lungs with 280 non-cardiovascular findings in 176 / 300 (58.7%) of patients, the airway with 139 non-cardiovascular findings in 103 / 300 (34.3%) of patients and the liver with 108 non-cardiovascular findings in 72 / 300 (24.0%) of patients. Syndromic associations were noted in 22% (n = 66 / 300) of the patients. Non-cardiovascular findings are common in children with

  12. Angiography and interventional radiology of the kidneys

    International Nuclear Information System (INIS)

    Hansmann, J.; Richter, G.M.; Hallscheidt, P.; Duex, M.; Noeldge, G.; Kaufmann, G.W.

    1999-01-01

    For imaging of renal pathology a broad spectrum of radiologic diagnostic procedures are available which are, sometimes and particularly more recently, competing among each other in their diagnostic yield and relevance. For tumorous lesions ultrasound, computed tomography and magnetic resonance imaging are performed predominantly. Angiography is no longer required with the exception of highly selected cases and in some specific preoperative workup requirements. Until recently, catheter based digital subtraction angiography has been considered as gold standard. However, non-invasive techniques such as CT-angiography and MR-angiography are evolving parallel to their quantum leap of resolutions and readiness to use. Nevertheless, well accepted criteria for quality assessement of these new modalities are still lacking. More comparison studies are urgently warranted. Despite the availability of ultrashort pulse sequences applying the T1 relaxation reduction effect of gadolinium enhanced MR techniques overestimation of renal artery stenosis still poses a substantial problem. Renal intervention implies a variety of procedures such as plain angioplasty, stent placement, embolization of traumatic and both benign and malignant tumors. These methods have emerged over the last two decades from a more experimental nature to a fully accepted treatment option. When renal artery angioplasty is embedded in an aggressive approach including stenting as an adjunct for more complex cases, renal ostial lesions and a well organized follow-up regimen its therapeutic potential for treatment of renal insufficiency, malignant hypertension, for organ preservation bears a very high potential. Provided adequate periinterventional drug regimen restenosis rates may be as low as 10%. In highly selected cases capillary embolization might be used as an alternative to nephrectomy with a similar clinical outcome. Particularly the development of superselective small caliber embolization catheters

  13. Tomosynthesis applied to digital subtraction angiography

    International Nuclear Information System (INIS)

    Kruger, R.A.; Sedaghati, M.; Roy, D.G.; Liu, P.; Nelson, J.A.; Kubal, W.; Del Rio, P.

    1984-01-01

    This extension of the author's previous work on tomographic digital subtraction angiography (DSA) describes the theory of tomosynthetic DSA image reconstruction techniques. In addition to developing the resolution limits resulting from x-ray exposure length and image intensifier field curvature, the authors describe one method of image formation and show tomosynthetic DSA images of animal and human anatomy. Methods for improving the present technique are discussed

  14. Contrast settling in cerebral aneurysm angiography

    International Nuclear Information System (INIS)

    Wang Zhijie; Hoffmann, Kenneth R; Guterman, Lee R; Wang Zhou; Rudin, Stephen; Meng Hui

    2005-01-01

    During angiography, blood flow is visualized with a radiopaque contrast agent, which is denser than blood. In complex vasculature, such as cerebral saccular aneurysms, the density difference may produce an appreciable gravity effect, where the contrast material separates from blood and settles along the gravity direction. Although contrast settling has been occasionally reported before, the fluid mechanics behind it have not been explored. Furthermore, the severity of contrast settling in cerebral aneurysms varies significantly from case to case. Therefore, a better understanding of the physical principles behind this phenomenon is needed to evaluate contrast settling in clinical angiography. In this study, flow in two identical groups of sidewall aneurysm models with varying parent-vessel curvature was examined by angiography. Intravascular stents were deployed into one group of the models. To detect contrast settling, we used lateral view angiography. Time-intensity curves were analysed from the angiographic data, and a computational fluid dynamic analysis was conducted. Results showed that contrast settling was strongly related to the local flow dynamics. We used the Froude number, a ratio of flow inertia to gravity force, to characterize the significance of gravity force. An aneurysm with a larger vessel curvature experienced higher flow, which resulted in a larger Froude number and, thus, less gravitational settling. Addition of a stent reduced the aneurysmal flow, thereby increasing the contrast settling. We found that contrast settling resulted in an elevated washout tail in the time-intensity curve. However, this signature is not unique to contrast settling. To determine whether contrast settling is present, a lateral view should be obtained in addition to the anteroposterior (AP) view routinely used clinically so as to rule out contrast settling and hence to enable a valid time-intensity curve analysis of blood flow in the aneurysm

  15. Efficacy of dynamic CT perfusion imaging in conjunction with three dimensional CT angiography for the evaluation of acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Nakaguchi, Hiroshi; Teraoka, Akira; Adachi, Shinobu; Yanagibashi, Kazutaka [Teraoka Memorial Hospital, Shinichi, Hiroshima (Japan)

    2003-01-01

    Through the use of a high-speed spiral CT scanner (GEMedical HiSpeedZX/i), CT/P/A technique, where conventional CT, CT perfusion imaging (CTP) and CT angiography (CTA) are consecutively performed, can now be performed with an imaging time of 90 seconds and a total contrast medium volume of 100 ml. A prospective clinical study was performed to ascertain the effectiveness of CT/P/A in diagnosing acute ischemic strokes. Twenty-nine consecutive patients of Teraoka Memorial Hospital suspected of suffering from the occlusion or constriction of cerebral arteries and who underwent CT/P/A within 3 hours from the onset served as subjects. The sensitivity, specificity, or Odds ratio of CTP and CTA in detecting lesions that caused cerebral infarction was calculated. CTP detected a hypoperfusion area with a sensitivity, specificity, and Odds ratio of 80%, 64%, and 7.2. The sensitivity in lobar infarcts, white matter infarcts, basal ganglia infarcts, and brainstem infarcts was 100%, 100%, 100%, 0% (p=0.0022). The sensitivity and Odds ratio of CT/P/A in cerebral infarcts differed according to the diameter of the infarcts. That with infarcts of 10 mm or more was 91%, 20. That with infarcts smaller than 10 mm was 50%, 2. CTA detected arterial lesions that caused cerebral ischemic attack with a sensitivity of 94% and specificity of 90%. The examination time for CT/P/A was 18 minutes, total radiation time being 90 seconds. Although CT/P/A was ineffective for the diagnosis of brainstem infarcts and lesions smaller than 10 mm, CT/P/A was useful in detecting moderate-sized hypoperfusion areas and arterial lesions three-dimensionally before an infarct is completed. (author)

  16. Impact of organ-specific dose reduction on the image quality of head and neck CT angiography

    International Nuclear Information System (INIS)

    Schimmoeller, L.; Lanzman, R.S.; Heusch, P.; Dietrich, S.; Miese, F.; Aissa, J.; Heusner, T.A.; Antoch, G.; Kroepil, P.

    2013-01-01

    Organ-specific dose reduction (OSDR) algorithms can reduce radiation on radiosensitive organs up to 59 %. This study evaluates the influence of a new OSDR algorithm on image quality of head and neck computed tomographic angiography (CTA) in clinical routine. Sixty-two consecutive patients (68 ± 13 years) were randomised into two groups and imaged using 128-row multidetector CT. Group A (n = 31) underwent conventional CTA and group B (n = 31) CTA with a novel OSDR algorithm. Subjective and objective image quality were statistically compared. Subjective image quality was rated on a five-point scale. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated with region-of-interest measurements. The SNR of the common carotid artery and middle cerebral artery was 53.6 ± 22.7 and 43.3 ± 15.3 (group A) versus 54.1 ± 20.5 and 46.2 ± 14.6 (group B). The CNR was 40.0 ± 19.3 and 29.7 ± 12.0 (group A) compared with 40.7 ± 16.8 and 32.9 ± 10.9 (group B), respectively. Subjective image quality was excellent in both groups (mean score 4.4 ± 0.7 versus 4.4 ± 0.6). Differences between the two groups were not significant. The novel OSDR algorithm does not compromise image quality of head and neck CTA. Its application can be recommended for CTA in clinical routine to protect the thyroid gland and ocular lenses from unnecessary high radiation. (orig.)

  17. Non-invasive assessment of coronary artery bypass graft patency using 16-slice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Uren Neal G

    2007-06-01

    Full Text Available Abstract Background Invasive coronary angiography is the gold standard means of imaging bypass vessels and carries a small but potentially serious risk of local vascular complications, including myocardial infarction, stroke and death. We evaluated computed tomography as a non-invasive means of assessing graft patency. Methods Fifty patients with previous coronary artery bypass surgery who were listed for diagnostic coronary angiography underwent contrast enhanced computed tomography angiography using a 16-slice computed tomography scanner. Images were retrospectively gated to the electrocardiogram and two dimensional axial, multiplanar and three dimensional reconstructions acquired. Sensitivity, specificity, positive and negative predictive value, accuracy and level of agreement for detection of graft patency by multidetector computed tomography. Results A total of 116 grafts were suitable for analysis. The specificity of CT for the detection of graft patency was 100%, with a sensitivity of 92.8%, positive predictive value 100%, negative predictive value 85.8% and an accuracy of 94.8%. The kappa value of agreement between the two means of measuring graft patency was 0.9. Mean radiation dose was 9.0 ± 7.2 mSv for coronary angiography and 18.5 ± 4 mSv for computed tomography. Pooled analysis of eight studies, incorporating 932 grafts, confirmed a 97% accuracy for the detection of graft patency by multidetector computed tomography. Conclusion Computed tomography is an accurate, rapid and non-invasive method of assessing coronary artery bypass graft patency. However, this was achieved at the expense of an increase in radiation dose.

  18. Diagnostic accuracy of high-definition CT coronary angiography in high-risk patients

    International Nuclear Information System (INIS)

    Iyengar, S.S.; Morgan-Hughes, G.; Ukoumunne, O.; Clayton, B.; Davies, E.J.; Nikolaou, V.; Hyde, C.J.; Shore, A.C.; Roobottom, C.A.

    2016-01-01

    Aim: To assess the diagnostic accuracy of computed tomography coronary angiography (CTCA) using a combination of high-definition CT (HD-CTCA) and high level of reader experience, with invasive coronary angiography (ICA) as the reference standard, in high-risk patients for the investigation of coronary artery disease (CAD). Materials and methods: Three hundred high-risk patients underwent HD-CTCA and ICA. Independent experts evaluated the images for the presence of significant CAD, defined primarily as the presence of moderate (≥50%) stenosis and secondarily as the presence of severe (≥70%) stenosis in at least one coronary segment, in a blinded fashion. HD-CTCA was compared to ICA as the reference standard. Results: No patients were excluded. Two hundred and six patients (69%) had moderate and 178 (59%) had severe stenosis in at least one vessel at ICA. The sensitivity, specificity, positive predictive value, and negative predictive value were 97.1%, 97.9%, 99% and 93.9% for moderate stenosis, and 98.9%, 93.4%, 95.7% and 98.3%, for severe stenosis, on a per-patient basis. Conclusion: The combination of HD-CTCA and experienced readers applied to a high-risk population, results in high diagnostic accuracy comparable to ICA. Modern generation CT systems in experienced hands might be considered for an expanded role. - Highlights: • Diagnostic accuracy of High-Definition CT Angiography (HD-CTCA) has been assessed. • Invasive Coronary angiography (ICA) is the reference standard. • Diagnostic accuracy of HD-CTCA is comparable to ICA. • Diagnostic accuracy is not affected by coronary calcium or stents. • HD-CTCA provides a non-invasive alternative in high-risk patients.

  19. 3D-shaded surface rendering of gadolinium-enhanced MR angiography in congenital heart disease

    International Nuclear Information System (INIS)

    Okuda, S.; Kikinis, R.; Dumanli, H.; Geva, T.; Powell, A.J.; Chung, T.

    2000-01-01

    Background. Gadolinium-enhanced three-dimensional (3D) MR angiography is a useful imaging technique for patients with congenital heart disease. Objective. This study sought to determine the added value of creating 3D shaded surface displays compared to standard maximal intensity projection (MIP) and multiplanar reformatting (MPR) techniques when analyzing 3D MR angiography data. Materials and methods. Seventeen patients (range, 3 months to 51 years old) with a variety of congenital cardiovascular defects underwent gadolinium-enhanced 3D MR angiography of the thorax. Color-coded 3D shaded surface models were rendered from the image data using manual segmentation and computer-based algorithms. Models could be rotated, translocated, or zoomed interactively by the viewer. Information available from the 3D models was compared to analysis based on viewing standard MIP/MPR displays. Results. Median postprocessing time for the 3D models was 6 h (range, 3-25 h) compared to approximately 20 min for MIP/MPR viewing. No additional diagnostic information was gained from 3D model analysis. All major findings with MIP/MPR postprocessing were also apparent on the 3D models. Qualitatively, the 3D models were more easily interpreted and enabled adjacent vessels to be distinguished more readily. Conclusion. Routine use of 3D shaded surface reconstructions for visualization of contrast enhanced MR angiography in congenital heart disease cannot be recommended. 3D surface rendering may be more useful for presenting complex anatomy to an audience unfamiliar with congenital heart disease and as an educational tool. (orig.)

  20. Digital subtraction angiography in 105 living renal transplant donors

    International Nuclear Information System (INIS)

    Suh, Ho Jong; Oh, Kyung Seung; Kim, So Sun; Huh, Jin Do; Kim, Ho Joon; Chun, Byung Hee; Joh, Young Duck

    1989-01-01

    In order to analyze the number and length of the renal arteries and to evaluate abnormalities of the renal parenchyma and vessel, digital subtraction angiogram images of 105 potential renal donors (45 men and 60 women aged 17-66 years) were studied retrospectively. For the entire series, 31 donors had multiple renal arteries on one side (15 on the left, 11 on the right) and 5 donors on the both sides. 89 donors were family related either parents or siblings of recipients. The estimation of the length of the renal artery was based on the mean height of the second lumbar vertebral body (L2). The right renal artery is significant longer than on the left and measured more than the height of L2 vertebral body in 84 cases on the right and 60 cases on the left. Twenty two donors underwent right nephrectomy due to presence of multiple renal arteries on the left (N=14), proximal bifurcation of left main renal artery (N=3), and young females in reproductive age (N=5). Unexpected abnormalities found with angiogram were seen in 7 cases and they include renal artery stenosis (N=2), renal cysts (N=4) and focal infarction (N=1). In cases of the renal cysts and focal infarction, there were no serious complications related to the abnormalities. It is conclude that intra-arterial digital subtraction angiography is safe and efficient method to image renal anatomy of the potential renal donors

  1. Magnetic resonance angiography for the head and neck region

    International Nuclear Information System (INIS)

    Aschenbach, R.; Esser, D.

    2004-01-01

    Magnetic resonance angiography is a noninvasive method in vascular imaging using noncontrast- enhanced and contrast-enhanced techniques. The contrast media used in contrast- enhanced magnetic resonance angiography are different from the X-ray contrast media and do not affect the thyroid gland or renal function. In detecting hypervascularized lesions in the head and neck, contrast-enhanced magnetic resonance angiography is the method of choice, which provides an acceptable quality in comparison to digital subtraction angiography. Future developments in magnetic resonance imaging techniques will cause a wider use of magnetic resonance angiography, especially in head and neck imaging. Digital subtraction angiography should therefore only be used in problem cases and for preoperative embolization [de

  2. Intraarterial digital subtraction angiography after coronary bypass surgery - an alternative to coronary angiography

    International Nuclear Information System (INIS)

    Hauenstein, H.K.; Roeren, T.; Schlosser, V.; Urbani, B.

    1985-01-01

    Intraarterial digital subtraction angiography after coronary bypass surgery - an alternative to coronary angiography. Intraarterial DSA is a suitable method for early postoperative control of coronary artery bypass grafts. Small quantities of contrast media with low iodine content are injected into the aortic root. Investigations can be carried out with a routine fluoroscopic and digital equipment; additional cine-technique and analogue memory disc are not necessary. At an image rate of 3/s the bypass anastomoses can be exactly visualized in 75%, whereas diagnostic information was not sufficient in only 4% of all cases. The use of modern F-5-catheters and the nonselective injection make this method a less invasive alternative to coronary angiography. It is paticularly useful in evaluation of short- and long-term results. (orig.) [de

  3. Multidetector CT angiography influences the choice of treatment for blunt carotid artery injury.

    Science.gov (United States)

    Beliaev, Andrei M; Civil, Ian

    2014-08-06

    A 43-year-old woman presented with a 2 h history of left neck pain after striking her neck against a marble bench while playing with her son. The patient was screened for blunt cerebrovascular injury (BCVI) and a left carotid bruit was identified. Subsequently, she underwent multidetector CT angiography (MCTA) of the aortic arch and neck vessels, which demonstrated a flow-limiting dissection of the left common carotid artery (CCA). The patient was started on heparin infusion and underwent an emergency operation. At surgery, a circumferential intimal dissection was excised and the arteriotomy defect closed with an autologous venous patch. This case emphasises the importance of adequately examining patients with direct injury to the neck, screening relevant patients for BCVI and investigating them with MCTA that influences the choice of a treatment option. 2014 BMJ Publishing Group Ltd.

  4. Feasibility and Diagnostic Accuracy of Whole Heart Coronary MR Angiography Using Free-Breathing 3D Balanced Turbo-Field-Echo with SENSE and the Half-Fourier Acquisition Technique

    International Nuclear Information System (INIS)

    Kim, Young Jin; Seo, Jae Seung; Choi, Byoung Wook; Choe, Kyu Ok; Jang, Yang Soo; Ko, Young Guk

    2006-01-01

    We wanted to assess the feasibility and diagnostic accuracy of whole heart coronary magnetic resonance angiography (MRA) with using 3D balanced turbo-field-echo (b-TFE) with SENSE and the half-Fourier acquisition technique for identifying stenoses of the coronary artery. Twenty-one patients who underwent both whole heart coronary MRA examinations and conventional catheter coronary angiography examinations were enrolled in the study. The whole heart coronary MRA images were acquired using a navigator gated 3D b-TFE sequence with SENSE and the half-Fourier acquisition technique to reduce the acquisition time. The imaging slab covered the whole heart (80 contiguous slices with a reconstructed slice thickness of 1.5 mm) along the transverse axis. The quality of the images was evaluated by using a 5-point scale (0 - uninterpretable, 1 - poor, 2 - fair, 3 - good, 4 - excellent). Ten coronary segments of the heart were evaluated in each case; the left main coronary artery (LM), and the proximal, middle and distal segments of the left anterior descending (LAD), the left circumflex (LCX) and the right coronary artery (RCA). The diagnostic accuracy of whole heart coronary MRA for detecting significant coronary artery stenosis was determined on the segment-bysegment basis, and it was compared with the results obtained by conventional catheter angiography, which is the gold standard. The mean image quality was 3.7 in the LM, 3.2 in the LAD, 2.5 in the LCX, and 3.3 in the RCA, respectively (the overall image quality was 3.0 ± 0.1). 168 (84%) of the 201 segments had an acceptable image quality (≥ grade 2). The sensitivity, specificity, accuracy, negative predictive value and positive predictive value of the whole heart coronary MRA images for detecting significant stenosis were 81.3%, 92.1%, 91.1%, 97.9%, and 52.0%, respectively. The mean coronary MRA acquisition time was 9 min 22 sec (± 125 sec). Whole heart coronary MRA is a feasible technique, and it has good potential to

  5. A comparative analysis of pulmonary ventilation-perfusion imaging with pulmonary angiography in the diagnosis of pulmonary embolism

    International Nuclear Information System (INIS)

    Wang Jincheng; Mi Hongzhi; Wang Qian; Zhang Weijun; Lu Biao; Yang Hao; Ding Jian; Lu Yao

    2001-01-01

    Objective: To assess the value of ventilation-perfusion imaging in the diagnosis of pulmonary embolism (PE). Methods: Thirty consecutive patients with clinically suspected pulmonary embolism were studied, male: female 15:15, mean age was (36.2 +- 13.9) years. The chest radiograms were obtained in all 30 patients. All patients underwent radionuclide ventilation-perfusion imaging and pulmonary angiography. Results: Of the 30 patients, 22 with lobe, multiple segment or multi-subsegment perfusion defects and normal or nearly normal ventilation images were reported as PE. 20 of them were confirmed to be with PE by pulmonary angiography, 2 patients were not confirmed. Eight of 30 patients with multiple perfusion defects, ventilative abnormalities were reported as non-PE and the diagnoses were confirmed by pulmonary angiography. The sensitivity, specificity and accuracy of diagnosis of PE by ventilation-perfusion imaging was 100%, 80.0% and 93.3% respectively. Conclusions: (1) Ventilation-perfusion imaging is one of the most valuable methods in the diagnosis of PE. (2) The results suggest that pulmonary embolism can be diagnosed non-invasively in most patients on the basis of clinical manifestation, chest radiograms and ventilation-perfusion imaging findings. (3) Pulmonary angiography is required while clinical manifestation and ventilation-perfusion imaging findings are discordant with each other

  6. Blunt splenic injuries in the adolescent trauma population: the role of angiography and embolization.

    Science.gov (United States)

    Mayglothling, Julie A; Haan, James M; Scalea, Thomas M

    2011-07-01

    Splenic artery embolization (SAE) improves non-operative splenic salvage rates in adults, but its utility and safety in the pediatric population is less well defined. Because adolescent trauma patients are often triaged to adult trauma centers, we were interested in evaluating SAE in this particular population. We hypothesize that angiography and embolization is a safe and effective adjunct to non-operative management in the adolescent population. A retrospective review of all patients aged 13-17 years admitted to our Level I Trauma Center with blunt splenic injury from 1997-2005 was performed. We reviewed patient demographics, operative reports, admission, and follow-up abdominal computed tomography (ACT) results, angiographic reports, and patient outcomes. A total of 97 patients were reviewed. Eighteen patients underwent immediate surgery, and 79 of the remaining patients had planned non-operative management. Of those participating in non-operative management, 35/79 (44%) were initially observed and 44/79 (56%) underwent initial angiography, 23/44 having embolization. Patients in the embolization group had an overall high grade of injury (American Association for the Surgery of Trauma mean grade 3.3, SD 0.6). The overall splenic salvage rate was 96% (76/79) in the non-operative management group; 100% splenic salvage was seen in the observational group; 100% salvage was also seen in patients with negative angiography, and 87% salvage (20/23) in the splenic artery embolization group. Splenic artery embolization may be a valuable adjunct in adolescent blunt splenic injury, especially in higher grade injuries or with evidence of splenic vascular injury on ACT. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Factors related to postoperative pain among patients who underwent radiofrequency ablation of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Hsieh, Y.-C.; Yap, Y.-S.; Hung, C.-H.; Chen, C.-H.; Lu, S.-N.; Wang, J.-H.

    2013-01-01

    Aim: To evaluate the incidence and associated factors of postoperative intense pain and haemodynamic changes during radiofrequency ablation of hepatocellular carcinoma. Materials and methods: A total of 123 consecutive hepatocellular carcinoma patients who underwent radiofrequency ablation were prospectively recruited. Patient factors, tumour characteristics, procedural factors, intraoperative haemodynamic changes, complications, postoperative events, laboratory values before and after ablation, and postoperative pain were evaluated. Postoperative pain was scored using a visual analogue scale after the procedure. Results: The mean age of the patients was 65.6 ± 9.6 years. In multiple logistic regression analysis, patients who underwent general anaesthesia [odds ratio (95% CI): 2.68 (1.23–5.81); p = 0.013] and had more postoperative nausea and vomiting episodes [3.10 (1.11–8.63); p = 0.036] were associated with intense pain. These findings remain robust after propensity score matching. For mean difference values between before and after RFA, higher in change in aspartate transaminase (p = 0.026), alanine transaminase (p = 0.016) and white blood cell count (p = 0.015), and lower in change in haemoglo