WorldWideScience

Sample records for underwent compton scattering

  1. Compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Botto, D.J.; Pratt, R.H.

    1979-05-01

    The current status of Compton scattering, both experimental observations and the theoretical predictions, is examined. Classes of experiments are distinguished and the results obtained are summarized. The validity of the incoherent scattering function approximation and the impulse approximation is discussed. These simple theoretical approaches are compared with predictions of the nonrelativistic dipole formula of Gavrila and with the relativistic results of Whittingham. It is noted that the A/sup -2/ based approximations fail to predict resonances and an infrared divergence, both of which have been observed. It appears that at present the various available theoretical approaches differ significantly in their predictions and that further and more systematic work is required.

  2. Connecting Compton and Gravitational Compton Scattering

    Directory of Open Access Journals (Sweden)

    Holstein Barry R.

    2017-01-01

    Full Text Available The study of Compton scattering—S + γ → S + γ—at MAMI and elsewhere has led to a relatively successful understanding of proton structure via its polarizabilities. The recent observation of gravitational radiation observed by LIGO has raised the need for a parallel understanding of gravitational Compton scattering—S + g → S + g—and we show here how it can be obtained from ordinary Compton scattering by use of the double copy theorem.

  3. Weak Deeply Virtual Compton Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Ales Psaker; Wolodymyr Melnitchouk; Anatoly Radyushkin

    2007-03-01

    We extend the analysis of the deeply virtual Compton scattering process to the weak interaction sector in the generalized Bjorken limit. The virtual Compton scattering amplitudes for the weak neutral and charged currents are calculated at the leading twist within the framework of the nonlocal light-cone expansion via coordinate space QCD string operators. Using a simple model, we estimate cross sections for neutrino scattering off the nucleon, relevant for future high intensity neutrino beam facilities.

  4. Observation of Nonlinear Compton Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Kotseroglou, T.

    2003-12-19

    This experiment tests Quantum Electrodynamics in the strong field regime. Nonlinear Compton scattering has been observed during the interaction of a 46.6 GeV electron beam with a 10{sup 18} W/cm{sup 2} laser beam. The strength of the field achieved was measured by the parameter {eta} = e{var_epsilon}{sub rms}/{omega}mc = 0.6. Data were collected with infrared and green laser photons and circularly polarized laser light. The timing stabilization achieved between the picosecond laser and electron pulses has {sigma}{sub rms} = 2 ps. A strong signal of electrons that absorbed up to 4 infrared photons (or up to 3 green photons) at the same point in space and time, while emitting a single gamma ray, was observed. The energy spectra of the scattered electrons and the nonlinear dependence of the electron yield on the field strength agreed with the simulation over 3 orders of magnitude. The detector could not resolve the nonlinear Compton scattering from the multiple single Compton scattering which produced rates of scattered electrons of the same order of magnitude. Nevertheless, a simulation has studied this difference and concluded that the scattered electron rates observed could not be accounted for only by multiple ordinary Compton scattering; nonlinear Compton scattering processes are dominant for n {ge} 3.

  5. Narrowband Compton Scattering Yield Enhancement

    Science.gov (United States)

    Rykovanov, Sergey; Seipt, Daniel; Kharin, Vasily

    2017-10-01

    Compton Scattering (CS) of laser light off high-energy electrons is a well-established source of X- and gamma-rays for applications in medicine, biology, nuclear and material sciences. Main advantage of CS photon sources is the possibility to generate narrow spectra as opposed to a broad continuum obtained when utilizing Bremsstrahlung. However, due to the low cross-section of the linear process, the total photon yield is quite low. The most straightforward way to increase the number of photon-electron beam scattering events is to increase the laser pulse intensity at the interaction point by harder focusing. This leads to an unfortunate consequence. Increase in the laser pulse normalized amplitude a0, leads to additional ponderomotive spectrum broadening of the scattered radiation. The ponderomotive broadening is caused by the v × B force, which slows the electron down near the peak of the laser pulse where the intensity is high, and can be neglected near the wings of the pulse, where the intensity is low. We show that laser pulse chirping, both nonlinear (laser pulse frequency ''following'' the envelope of the pulse) and linear, leads to compensation of the ponderomotive broadening and considerably enhances the yield of the nonlinear Compton sources. Work supported by the Helmholtz Association via Helmholtz Young Investigators Grant (VH-NG-1037).

  6. Computer control in a compton scattering spectrometer

    International Nuclear Information System (INIS)

    Cui Ningzhuo; Chen Tao; Gong Zhufang; Yang Baozhong; Mo Haiding; Hua Wei; Bian Zuhe

    1995-01-01

    The authors introduced the hardware and software of computer autocontrol of calibration and data acquisition in a Compton Scattering spectrometer which consists of a HPGe detector, Amplifiers and a MCA

  7. Testing special relativity theory using Compton scattering

    International Nuclear Information System (INIS)

    Contreras S, H.; Hernandez A, L.; Baltazar R, A.; Escareno J, E.; Mares E, C. A.; Hernandez V, C.; Vega C, H. R.

    2010-10-01

    The validity of the special relativity theory has been tested using the Compton scattering. Since 1905 several experiments has been carried out to show that time, mass, and length change with the velocity, in this work the Compton scattering has been utilized as a simple way to show the validity to relativity. The work was carried out through Monte Carlo calculations and experiments with different gamma-ray sources and a gamma-ray spectrometer with a 3 x 3 NaI (Tl) detector. The pulse-height spectra were collected and the Compton edge was observed. This information was utilized to determine the relationship between the electron's mass and energy using the Compton -knee- position, the obtained results were contrasted with two collision models between photon and electron, one model was built using the classical physics and another using the special relativity theory. It was found that calculations and experiments results fit to collision model made using the special relativity. (Author)

  8. Nucleon structure study by virtual compton scattering

    International Nuclear Information System (INIS)

    Berthot, J.; Bertin, P.Y.; Breton, V.; Fonvielle, H.; Hyde-Wright, C.; Quemener, G.; Ravel, O.; Braghieri, A.; Pedroni, P.; Boeglin, W.U.; Boehm, R.; Distler, M.; Edelhoff, R.; Friedrich, J.; Geiges, R.; Jennewein, P.; Kahrau, M.; Korn, M.; Kramer, H.; Krygier, K.W.; Kunde, V.; Liesenfeld, A.; Merle, K.; Neuhausen, R.; Offermann, E.A.J.M.; Pospischil, T.; Rosner, G.; Sauer, P.; Schmieden, H.; Schardt, S.; Tamas, G.; Wagner, A.; Walcher, T.; Wolf, S.

    1995-01-01

    We propose to study nucleon structure by Virtual Compton Scattering using the reaction p(e,e'p)γ with the MAMI facility. We will detect the scattered electron and the recoil proton in coincidence in the high resolution spectrometers of the hall A1. Compton events will be separated from the other channels (principally π 0 production) by missing-mass reconstruction. We plan to investigate this reaction near threshold. Our goal is to measure new electromagnetic observables which generalize the usual magnetic and electric polarizabilities. (authors). 9 refs., 18 figs., 7 tabs

  9. Compton scattering collision module for OSIRIS

    Science.gov (United States)

    Del Gaudio, Fabrizio; Grismayer, Thomas; Fonseca, Ricardo; Silva, Luís

    2017-10-01

    Compton scattering plays a fundamental role in a variety of different astrophysical environments, such as at the gaps of pulsars and the stagnation surface of black holes. In these scenarios, Compton scattering is coupled with self-consistent mechanisms such as pair cascades. We present the implementation of a novel module, embedded in the self-consistent framework of the PIC code OSIRIS 4.0, capable of simulating Compton scattering from first principles and that is fully integrated with the self-consistent plasma dynamics. The algorithm accounts for the stochastic nature of Compton scattering reproducing without approximations the exchange of energy between photons and unbound charged species. We present benchmarks of the code against the analytical results of Blumenthal et al. and the numerical solution of the linear Kompaneets equation and good agreement is found between the simulations and the theoretical models. This work is supported by the European Research Council Grant (ERC- 2015-AdG 695088) and the Fundao para a Céncia e Tecnologia (Bolsa de Investigao PD/BD/114323/2016).

  10. Theorems of low energy in Compton scattering

    International Nuclear Information System (INIS)

    Chahine, J.

    1984-01-01

    We have obtained the low energy theorems in Compton scattering to third and fouth order in the frequency of the incident photon. Next we calculated the polarized cross section to third order and the unpolarized to fourth order in terms of partial amplitudes not covered by the low energy theorems, what will permit the experimental determination of these partial amplitudes. (Author) [pt

  11. Induced Compton scattering effects in radiation transport approximations

    International Nuclear Information System (INIS)

    Gibson, D.R. Jr.

    1982-01-01

    In this thesis the method of characteristics is used to solve radiation transport problems with induced Compton scattering effects included. The methods used to date have only addressed problems in which either induced Compton scattering is ignored, or problems in which linear scattering is ignored. Also, problems which include both induced Compton scattering and spatial effects have not been considered previously. The introduction of induced scattering into the radiation transport equation results in a quadratic nonlinearity. Methods are developed to solve problems in which both linear and nonlinear Compton scattering are important. Solutions to scattering problems are found for a variety of initial photon energy distributions

  12. Deeply virtual Compton scattering off nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Voutier, Eric

    2009-01-01

    Deeply virtual Compton scattering (DVCS) is the golden exclusive channel for the study of the partonic structure of hadrons, within the universal framework of generalized parton distributions (GPDs). This paper presents the aim and general ideas of the DVCS experimental program off nuclei at the Jefferson Laboratory. The benefits of the study of the coherent and incoherent channels to the understanding of the EMC (European Muon Collaboration) effect are discussed, along with the case of nuclear targets to access neutron GPDs.

  13. High-Energy Compton Scattering Light Sources

    CERN Document Server

    Hartemann, Fred V; Barty, C; Crane, John; Gibson, David J; Hartouni, E P; Tremaine, Aaron M

    2005-01-01

    No monochromatic, high-brightness, tunable light sources currently exist above 100 keV. Important applications that would benefit from such new hard x-ray sources include: nuclear resonance fluorescence spectroscopy, time-resolved positron annihilation spectroscopy, and MeV flash radiography. The peak brightness of Compton scattering light sources is derived for head-on collisions and found to scale with the electron beam brightness and the drive laser pulse energy. This gamma 2

  14. Compton scattering: the investigation of electron momentum distributions

    International Nuclear Information System (INIS)

    Williams, B.

    1977-01-01

    A collection of review papers is presented on Compton scattering. The history, theory, experimentation, multiple scattering, atoms, solids, chemistry, electron scattering, positron annihilation, and the reconstruction of the three-dimensional distributions are the topics considered. 88 references

  15. Proton compton scattering in the resonance region

    International Nuclear Information System (INIS)

    Ishii, Takanobu.

    1979-12-01

    Differential cross sections of the proton Compton scattering have been measured in the energy range between 400 and 1150 MeV at CMS angles of 130 0 , 100 0 and 70 0 . The recoil proton was detected with a magnetic spectrometer using multi-wire proportional chambers and wire spark chambers. In coincidence with the proton, the scattered photon was detected with a lead glass Cerenkov counter of the total absorption type with a lead plate converter, and horizontal and vertical scintillation counter hodoscopes. The background due to the neutral pion photoproduction, was subtracted by using the kinematic relations between the scattered photon and the recoil proton. Theoretical calculations based on an isobar model with two components, that is, the resonance plus background, were done, and the photon couplings of the second resonance region were determined firstly from the proton Compton data. The results are that the helicity 1/2 photon couplings of P 11 (1470) and S 11 (1535), and the helicity 3/2 photon coupling of D 13 (1520) are consistent with those determined from the single pion photoproduction data, but the helicity 1/2 photon coupling of D 13 (1520) has a somewhat larger value than that from the single pion photoproduction data. (author)

  16. Relativistic wave equations and compton scattering

    International Nuclear Information System (INIS)

    Sutanto, S.H.; Robson, B.A.

    1998-01-01

    Full text: Recently an eight-component relativistic wave equation for spin-1/2 particles was proposed.This equation was obtained from a four-component spin-1/2 wave equation (the KG1/2 equation), which contains second-order derivatives in both space and time, by a procedure involving a linearisation of the time derivative analogous to that introduced by Feshbach and Villars for the Klein-Gordon equation. This new eight-component equation gives the same bound-state energy eigenvalue spectra for hydrogenic atoms as the Dirac equation but has been shown to predict different radiative transition probabilities for the fine structure of both the Balmer and Lyman a-lines. Since it has been shown that the new theory does not always give the same results as the Dirac theory, it is important to consider the validity of the new equation in the case of other physical problems. One of the early crucial tests of the Dirac theory was its application to the scattering of a photon by a free electron: the so-called Compton scattering problem. In this paper we apply the new theory to the calculation of Compton scattering to order e 2 . It will be shown that in spite of the considerable difference in the structure of the new theory and that of Dirac the cross section is given by the Klein-Nishina formula

  17. Virtual Compton scattering off protons at moderately large momentum transfer

    International Nuclear Information System (INIS)

    Kroll, P.

    1996-01-01

    The amplitudes for virtual Compton scattering off protons are calculated within the framework of the diquark model in which protons are viewed as being built up by quarks and diquarks. The latter objects are treated as quasi-elementary constituents of the proton. Virtual Compton scattering, electroproduction off protons and the Bethe-Heitler contamination are photon discussed for various kinematical situations. We particularly emphasize the role of the electron asymmetry for measuring the relative phases between the virtual Compton and the Bethe-Heitler amplitudes. It is also shown that the model is able to describe very well the experimental data for real Compton scattering off protons. (orig.)

  18. Virtual compton scattering at low energy

    International Nuclear Information System (INIS)

    Lhuillier, D.

    1997-09-01

    The work described in this PhD is a study of the Virtual Compton scattering (VCS) off the proton at low energy, below pion production threshold. Our experiment has been carried out at MAMI in the collaboration with the help of two high resolution spectrometers. Experimentally, the VCS process is the electroproduction of photons off a liquid hydrogen target. First results of data analysis including radiative corrections are presented and compared with low energy theorem prediction. VCS is an extension of the Real Compton Scattering. The virtuality of the incoming photon allows us to access new observables of the nucleon internal structure which are complementarity to the elastic form factors: the generalized polarizabilities (GP). They are function of the squared invariant mass of the virtual photo. The mass limit of these observables restore the usual electric and magnetic polarizabilities. Our experiment is the first measurement of the VCS process at a virtual photon mass equals 0.33 Ge V square. The experimental development presents the analysis method. The high precision needed in the absolute cross-section measurement required an accurate estimate of radiative corrections to the VCS. This new calculation, which has been performed in the dimensional regulation scheme, composes the theoretical part of this thesis. At low q', preliminary results agree with low energy theorem prediction. At higher q', substraction of low energy theorem contribution to extract GP is discussed. (author)

  19. Virtual Compton Scattering At High Energy

    CERN Document Server

    Zhang, C

    2000-01-01

    In this dissertation we develop a theoretical framework in the context of perturbative QuantumChromoDynamics (pQCD) for studying non-forward scattering processes. In particular, we investigate a non-forward unequal mass virtual Compton scattering amplitude by performing the general operator product expansion (OPE) and the formal renormalization group (RG) analysis. We discuss the general tensorial decomposition of the amplitude to obtain the invariant amplitudes in the non- forward kinematic region. We study the OPE to identify the relevant operators and their reduced matrix elements, as well as the corresponding Wilson coefficients. We find that the OPE now should be done in double moments with new moment variables. There are in the expansion new sets of leading twist operators which have overall derivatives. They mix under renormalization in a well- defined way. We compute the evolution kernels from which the anomalous dimensions for these operators can be extracted. We also obtain explicitly the lowest ord...

  20. Compton scatter correction for planner scintigraphic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Vaan Steelandt, E.; Dobbeleir, A.; Vanregemorter, J. [Algemeen Ziekenhuis Middelheim, Antwerp (Belgium). Dept. of Nuclear Medicine and Radiotherapy

    1995-12-01

    A major problem in nuclear medicine is the image degradation due to Compton scatter in the patient. Photons emitted by the radioactive tracer scatter in collision with electrons of the surrounding tissue. Due to the resulting loss of energy and change in direction, the scattered photons induce an object dependant background on the images. This results in a degradation of the contrast of warm and cold lesions. Although theoretically interesting, most of the techniques proposed in literature like the use of symmetrical photopeaks can not be implemented on the commonly used gamma camera due to the energy/linearity/sensitivity corrections applied in the detector. A method for a single energy isotope based on existing methods with adjustments towards daily practice and clinical situations is proposed. It is assumed that the scatter image, recorded from photons collected within a scatter window adjacent to the photo peak, is a reasonable close approximation of the true scatter component of the image reconstructed from the photo peak window. A fraction `k` of the image using the scatter window is subtracted from the image recorded in the photo peak window to produce the compensated image. The principal matter of the method is the right value for the factor `k`, which is determined in a mathematical way and confirmed by experiments. To determine `k`, different kinds of scatter media are used and are positioned in different ways in order to simulate a clinical situation. For a secondary energy window from 100 to 124 keV below a photo peak window from 126 to 154 keV, a value of 0.7 is found. This value has been verified using both an antropomorph thyroid phantom and the Rollo contrast phantom.

  1. Deconvolution of shift-variant broadening for Compton scatter imaging

    International Nuclear Information System (INIS)

    Evans, Brian L.; Martin, Jeffrey B.; Roggemann, Michael C.

    1999-01-01

    A technique is presented for deconvolving shift-variant Doppler broadening of singly Compton scattered gamma rays from their recorded energy distribution. Doppler broadening is important in Compton scatter imaging techniques employing gamma rays with energies below roughly 100 keV. The deconvolution unfolds an approximation to the angular distribution of scattered photons from their recorded energy distribution in the presence of statistical noise and background counts. Two unfolding methods are presented, one based on a least-squares algorithm and one based on a maximum likelihood algorithm. Angular distributions unfolded from measurements made on small scattering targets show less evidence of Compton broadening. This deconvolution is shown to improve the quality of filtered backprojection images in multiplexed Compton scatter tomography. Improved sharpness and contrast are evident in the images constructed from unfolded signals

  2. Deeply virtual Compton scattering off 4He

    International Nuclear Information System (INIS)

    Hattawy, M.

    2015-01-01

    The 4 He nucleus is of particular interest to study nuclear GPDs (Generalized Parton Distributions) as its partonic structure is described by only one chirally-even GPD. It is also a simple few-body system and has a high density that makes it the ideal target to investigate nuclear effects on partons. The experiment described in this thesis is JLab-E08-24, which was carried out in 2009 by the CLAS collaboration during the 'EG6' run. In this experiment, a 6 GeV longitudinally-polarized electron beam was scattered onto a 6 atm 4 He gaseous target. During this experiment, in addition to the CLAS detector, a Radial Time Projection Chamber (RTPC), to detect low-energy nuclear recoils, and an Inner Calorimeter (IC), to improve the detection of photons at very forward angles, were used. We carried out a full analysis on our 6 GeV dataset, showing the feasibility of measuring exclusive nuclear Deeply Virtual Compton Scattering (DVCS) reactions. The analysis included: the identification of the final-state particles, the DVCS event selection, the π 0 background subtraction. The beam-spin asymmetry was then extracted for both DVCS channels and compared to the ones of the free-proton DVCS reaction, and to theoretical predictions from two models. Finally, the real and the imaginary parts of the 4 He CFF (Compton Form Factor) HA have been extracted. Different levels of agreement were found between our measurements and the theoretical calculations. This thesis is organized as follows: In chapter 1, the available theoretical tools to study hadronic structure are presented, with an emphasis on the nuclear effects and GPDs. In chapter 2, the characteristics of the CLAS spectrometer are reviewed. In chapter 3, the working principle and the calibration aspects of the RTPC are discussed. In chapter 4, the identification of the final-state particles and the Monte-Carlo simulation are presented. In chapter 5, the selection of the DVCS events, the background subtraction, and

  3. Polarization observables in Virtual Compton Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Doria, Luca

    2007-10-15

    Virtual Compton Scattering (VCS) is an important reaction for understanding nucleon structure at low energies. By studying this process, the generalized polarizabilities of the nucleon can be measured. These observables are a generalization of the already known polarizabilities and will permit theoretical models to be challenged on a new level. More specifically, there exist six generalized polarizabilities and in order to disentangle them all, a double polarization experiment must be performed. Within this work, the VCS reaction p(e,e'p){gamma} was measured at MAMI using the A1 Collaboration three spectrometer setup with Q{sup 2}=0.33 (GeV/c){sup 2}. Using the highly polarized MAMI beam and a recoil proton polarimeter, it was possible to measure both the VCS cross section and the double polarization observables. Already in 2000, the unpolarized VCS cross section was measured at MAMI. In this new experiment, we could confirm the old data and furthermore the double polarization observables were measured for the first time. The data were taken in five periods between 2005 and 2006. In this work, the data were analyzed to extract the cross section and the proton polarization. For the analysis, a maximum likelihood algorithm was developed together with the full simulation of all the analysis steps. The experiment is limited by the low statistics due mainly to the focal plane proton polarimeter efficiency. To overcome this problem, a new determination and parameterization of the carbon analyzing power was performed. The main result of the experiment is the extraction of a new combination of the generalized polarizabilities using the double polarization observables. (orig.)

  4. Colour coherence in deep inelastic Compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Lebedev, A.I.; Vazdik, J.A. (Lebedev Physical Inst., Academy of Sciences, Moscow (USSR))

    1992-01-01

    MC simulation of Deep Inelastic Compton on proton - both QED and QCD - was performed on the basis of LUCIFER program for HERA energies. Charged hadron flow was calculated for string and independent fragmentation with different cuts on p{sub t} and x. It is shown that interjet colour coherence leads in the case of QCD Compton to the drag effects diminishing the hadron flow in the direction between quark jet and proton remnant jet. (orig.).

  5. Colour coherence in deep inelastic Compton scattering

    International Nuclear Information System (INIS)

    Lebedev, A.I.; Vazdik, J.A.

    1992-01-01

    MC simulation of Deep Inelastic Compton on proton - both QED and QCD - was performed on the basis of LUCIFER program for HERA energies. Charged hadron flow was calculated for string and independent fragmentation with different cuts on p t and x. It is shown that interjet colour coherence leads in the case of QCD Compton to the drag effects diminishing the hadron flow in the direction between quark jet and proton remnant jet. (orig.)

  6. The hydrogen anomaly problem in neutron Compton scattering

    Science.gov (United States)

    Karlsson, Erik B.

    2018-03-01

    Neutron Compton scattering (also called ‘deep inelastic scattering of neutrons’, DINS) is a method used to study momentum distributions of light atoms in solids and liquids. It has been employed extensively since the start-up of intense pulsed neutron sources about 25 years ago. The information lies primarily in the width and shape of the Compton profile and not in the absolute intensity of the Compton peaks. It was therefore not immediately recognized that the relative intensities of Compton peaks arising from scattering on different isotopes did not always agree with values expected from standard neutron cross-section tables. The discrepancies were particularly large for scattering on protons, a phenomenon that became known as ‘the hydrogen anomaly problem’. The present paper is a review of the discovery, experimental tests to prove or disprove the existence of the hydrogen anomaly and discussions concerning its origin. It covers a twenty-year-long history of experimentation, theoretical treatments and discussions. The problem is of fundamental interest, since it involves quantum phenomena on the subfemtosecond time scale, which are not visible in conventional thermal neutron scattering but are important in Compton scattering where neutrons have two orders of magnitude times higher energy. Different H-containing systems show different cross-section deficiencies and when the scattering processes are followed on the femtosecond time scale the cross-section losses disappear on different characteristic time scales for each H-environment. The last section of this review reproduces results from published papers based on quantum interference in scattering on identical particles (proton or deuteron pairs or clusters), which have given a quantitative theoretical explanation both regarding the H-cross-section reduction and its time dependence. Some new explanations are added and the concluding chapter summarizes the conditions for observing the specific quantum

  7. Some Issues in Deeply-Virtual Compton Scattering

    Directory of Open Access Journals (Sweden)

    Ji C.-R.

    2010-04-01

    Full Text Available Compton scattering provides a unique tool for studying hadron structure. In contrast to elastic electron scattering, which provides information about the hadron’s structure in terms of form factors, Compton scattering is more versatile, as the basic process is the coupling of two electro-magnetic currents. Therefore, the hadronic structure can be described at high momentum transfer in the language of generalized parton distributions (GPDs, which code information about the light-front wave functions of the probed hadrons. In this paper we discuss some issues involved in the application of the GPD idea, in particular the effectivity of Compton scattering as a filter of the hadron structure.

  8. Infrared phenomena in quantum electrodynamics : II. Bremsstrahlung and compton scattering

    NARCIS (Netherlands)

    Haeringen, W. van

    The infrared aspects of quantum electrodynamics are discussed by treating two examples of scattering processes, bremsstrahlung and Compton scattering. As in the previous paper one uses a non-covariant diagram technique which gives very clear insight in the cancelling of infrared divergences between

  9. Fast sampling algorithm for the simulation of photon Compton scattering

    International Nuclear Information System (INIS)

    Brusa, D.; Salvat, F.

    1996-01-01

    A simple algorithm for the simulation of Compton interactions of unpolarized photons is described. The energy and direction of the scattered photon, as well as the active atomic electron shell, are sampled from the double-differential cross section obtained by Ribberfors from the relativistic impulse approximation. The algorithm consistently accounts for Doppler broadening and electron binding effects. Simplifications of Ribberfors' formula, required for efficient random sampling, are discussed. The algorithm involves a combination of inverse transform, composition and rejection methods. A parameterization of the Compton profile is proposed from which the simulation of Compton events can be performed analytically in terms of a few parameters that characterize the target atom, namely shell ionization energies, occupation numbers and maximum values of the one-electron Compton profiles. (orig.)

  10. Analysis of materials in ducts by Compton scattering

    International Nuclear Information System (INIS)

    Gouveia, M.A.G.; Lopes, R.T.; Jesus, E.F.O. de; Camerini, C.S.

    2000-01-01

    This work presents the use of the Compton Scattering Technique as essay, for materials characterization in petroleum ducts. The essay have been accomplished in laboratory ambit, so that the presented results should be analyzed so that the system can come to be used in the field. The inspection was performed using Compton Scattering techniques, with two detectors aligned, in an angle of 90 degrees with a source of Cs-137 with energy of 662 keV. The results demonstrated the good capacity of the system to detect materials deposited in petroleum ducts during petroleum transportation. (author)

  11. A compact X-ray source based on Compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Bulyak, E.; Gladkikh, P.; Grigor' ev, Yu.; Guk, I.; Karnaukhov, I.; Khodyachikh, A.; Kononenko, S.; Mocheshnikov, N.; Mytsykov, A.; Shcherbakov, A. E-mail: shcherbakov@kipt.kharkov.ua; Tarasenko, A.; Telegin, Yu.; Zelinsky, A

    2001-07-21

    The main parameters of Kharkov electron storage ring N-100 with a beam energy range from 70 to 150 MeV are presented. The main results that were obtained in experimental researches are briefly described. The future of the N-100 upgrade to the development of the X-ray generator based on Compton back-scattering are presented. The electron beam energy range will be extended up to 250 MeV and the circumference of the storage ring will be 13.72 m. The lattice, parameters of the electron beam and the Compton back-scattering photons flux are described.

  12. A compact X-ray source based on Compton scattering

    International Nuclear Information System (INIS)

    Bulyak, E.; Gladkikh, P.; Grigor'ev, Yu.; Guk, I.; Karnaukhov, I.; Khodyachikh, A.; Kononenko, S.; Mocheshnikov, N.; Mytsykov, A.; Shcherbakov, A.; Tarasenko, A.; Telegin, Yu.; Zelinsky, A.

    2001-01-01

    The main parameters of Kharkov electron storage ring N-100 with a beam energy range from 70 to 150 MeV are presented. The main results that were obtained in experimental researches are briefly described. The future of the N-100 upgrade to the development of the X-ray generator based on Compton back-scattering are presented. The electron beam energy range will be extended up to 250 MeV and the circumference of the storage ring will be 13.72 m. The lattice, parameters of the electron beam and the Compton back-scattering photons flux are described

  13. Generalized parton distributions and deep virtual Compton scattering

    International Nuclear Information System (INIS)

    Hasell, D.; Milner, R.; Takase, K.

    2001-01-01

    A brief description of generalized parton distributions is presented together with a discussion on studying such distributions via deep virtual Compton scattering. The kinematics, estimates of rates, and accuracies achievable for measuring DVCS utilizing a 5+50 GeV ep collider are also provided

  14. New JLab/Hall A Deeply Virtual Compton Scattering results

    Energy Technology Data Exchange (ETDEWEB)

    Defurne, Maxime [CEA, Centre de Saclay, IRFU/SPhN/LSN, F-91191 Gif-sur-Yvette, France

    2015-08-01

    New data points for unpolarized Deeply Virtual Compton Scattering cross sections have been extracted from the E00-110 experiment at Q2=1.9 GeV2 effectively doubling the statistics available in the valence region. A careful study of systematic uncertainties has been performed.

  15. On the Compton scattering redistribution function in plasma

    Science.gov (United States)

    Madej, J.; Różańska, A.; Majczyna, A.; Należyty, M.

    2017-08-01

    Compton scattering is the dominant opacity source in hot neutron stars, accretion discs around black holes and hot coronae. We collected here a set of numerical expressions of the Compton scattering redistribution functions (RFs) for unpolarized radiation, which are more exact than the widely used Kompaneets equation. The principal aim of this paper is the presentation of the RF by Guilbert, which is corrected for the computational errors in the original paper. This corrected RF was used in the series of papers on model atmosphere computations of hot neutron stars. We have also organized four existing algorithms for the RF computations into a unified form ready to use in radiative transfer and model atmosphere codes. The exact method by Nagirner & Poutanen was numerically compared to all other algorithms in a very wide spectral range from hard X-rays to radio waves. Sample computations of the Compton scattering RFs in thermal plasma were done for temperatures corresponding to the atmospheres of bursting neutron stars and hot intergalactic medium. Our formulae are also useful to study the Compton scattering of unpolarized microwave background radiation in hot intracluster gas and the Sunyaev-Zeldovich effect. We conclude that the formulae by Guilbert and the exact quantum mechanical formulae yield practically the same RFs for gas temperatures relevant to the atmospheres of X-ray bursting neutron stars, T ≤ 108 K.

  16. Constraint on Parameters of Inverse Compton Scattering Model for ...

    Indian Academy of Sciences (India)

    J. Astrophys. Astr. (2011) 32, 299–300 c Indian Academy of Sciences. Constraint on Parameters of Inverse Compton Scattering Model for PSR B2319+60. H. G. Wang. ∗. & M. Lv. Center for Astrophysics,Guangzhou University, Guangzhou, China. ∗ e-mail: cosmic008@yahoo.com.cn. Abstract. Using the multifrequency radio ...

  17. Renormalized Compton scattering and nonlinear damping of collisionless drift waves

    International Nuclear Information System (INIS)

    Krommes, J.A.

    1979-05-01

    A kinetic theory for the nonlinear damping of collisionless drift waves in a shear-free magnetic field is presented. The general formalism is a renormalized version of induced scattering on the ions and reduces correctly to weak turbulence theory. The approximation studied explicitly reduces to Compton scattering, systematizes thee earlier calculations of Dupree and Tetreault (DT) [Phys. Fluids 21, 425 (1978)], and extends that theory to finite ion gyroradius. Certain conclusions differ significantly from those of DT

  18. Formal analogy between Compton scattering and Doppler effect

    DEFF Research Database (Denmark)

    Nielsen, A.; Olsen, Jørgen Seir

    1966-01-01

    Viewed from the scatterer, the energy of the incoming photon or particle is equal to that of the outgoing, and the angle of incidence is equal to the angle of reflection, when the direction of the velocity of the scatterer after the collision is taken as reference. This paper sets out to prove...... this statement in a more simple and direct way. The authors only consider the Compton scatting process as it is quite analogous to the particle case....

  19. The electromagnetic calorimeter in JLab Real Compton Scattering Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Albert Shahinyan; Eugene Chudakov; A. Danagoulian; P. Degtyarenko; K. Egiyan; V. Gorbenko; J. Hines; E. Hovhannisyan; Ch. Hyde; C.W. de Jager; A. Ketikyan; V. Mamyan; R. Michaels; A.M. Nathan; V. Nelyubin; I. Rachek; M. Roedelbrom; A. Petrosyan; R. Pomatsalyuk; V. Popov; J. Segal; Yu. Shestakov; J. Templon; H. Voskanyan; B. Wojtsekhowski

    2007-04-16

    A hodoscope calorimeter comprising of 704 lead-glass blocks is described. The calorimeter was constructed for use in the JLab Real Compton Scattering experiment. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV energy range with resolutions of 5 mm and 6\\%/$\\sqrt{E_\\gamma \\, [GeV]}$, respectively. Design features and performance parameters during the experiment are presented.

  20. Compton profiles by inelastic ion-electron scattering

    International Nuclear Information System (INIS)

    Boeckl, H.; Bell, F.

    1983-01-01

    It is shown that Compton profiles (CP) can be measured by inelastic ion-electron scattering. Within the impulse approximation the binary-encounter peak (BEP) reflects the CP of the target atom whereas the electron-loss peak (ELP) is given by projectile CP's. Evaluation of experimental data reveals that inelastic ion-electron scattering might be a promising method to supply inelastic electron or photon scattering for the determination of target CP's. The measurement of projectile CP's is unique to ion scattering since one gains knowledge about wave-function effects because of the high excitation degree of fast heavy-ion projectiles

  1. Electronic properties of Be and Al by Compton scattering technique

    International Nuclear Information System (INIS)

    Aguiar, J.C.; Di Rocco, H.O.

    2011-01-01

    In this work, electronic properties of beryllium and aluminum are examined by using Compton scattering technique. The method is based on the irradiation of samples using a beam narrow of mono- energetic photons of 59.54 keV product of radioactive decay of Am -241 . Scattered radiation is collected by a high resolution semiconductor detector positioned at an angle of 90°. The measured spectrum is commonly called Compton profile and contains useful information about the electronic structure of the material. The experimental results are compared with theoretical calculations such as density functional theory showing a good agreement. However, these results show some discrepancies with many libraries used in codes such as Monte Carlo simulation. Since these libraries are based on the values tabulated by Biggs, Mendelsohn and Mann 1975 thus overestimating the scattered radiation on the material. (authors) [es

  2. Comprehensive study of observables in Compton scattering on the nucleon

    Science.gov (United States)

    Grießhammer, Harald W.; McGovern, Judith A.; Phillips, Daniel R.

    2018-03-01

    We present an analysis of 13 observables in Compton scattering on the proton. Cross sections, asymmetries with polarised beam and/or targets, and polarisation-transfer observables are investigated for energies up to the Δ(1232) resonance to determine their sensitivity to the proton's dipole scalar and spin polarisabilities. The Chiral Effective Field Theory Compton amplitude we use is complete at N4LO, O(e2δ4), for photon energies ω˜ m_{π}, and so has an accuracy of a few per cent there. At photon energies in the resonance region, it is complete at NLO, O(e2δ0), and so its accuracy there is about 20%. We find that for energies from pion-production threshold to about 250 MeV, multiple asymmetries have significant sensitivity to presently ill-determined combinations of proton spin polarisabilities. We also argue that the broad outcomes of this analysis will be replicated in complementary theoretical approaches, e.g., dispersion relations. Finally, we show that below the pion-production threshold, 6 observables suffice to reconstruct the Compton amplitude, and above it 11 are required. Although not necessary for polarisability extractions, this opens the possibility to perform "complete" Compton-scattering experiments. An interactive Mathematica notebook, including results for the neutron, is available from judith.mcgovern@manchester.ac.uk.

  3. Laser Compton Scattering Gamma Ray Induced Photo-Trasmutation

    CERN Document Server

    Li, Dazhi

    2004-01-01

    High brightness beams of gamma rays produced with laser Compton scattering have the potential to realize photo-transmutation through (γ,n) reaction, implying an efficient method to dispose long-lived fission products. Preliminary investigations have been carried out in understanding the feasibility of development of a transmutation facility to repose nuclear waste. A laser Compton scattering experimental setup based on a storage ring started to generate gamma-ray beams for studying the coupling of gamma photons and nuclear giant resonance. This paper demonstrates the dependency of nuclear transmutation efficiency on target dimensions and gamma ray features. 197Au sample was adopted in our experiment, and experimental results correspond to the theoretical estimations.

  4. Deeply virtual compton scattering on a virtual pion target

    Energy Technology Data Exchange (ETDEWEB)

    Amrath, D.; Diehl, M. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Lansberg, J.P. [Ecole Polytechnique, 91 - Palaiseau (France). Centre de Physique Theorique]|[Heidelberg Univ. (Germany). Inst. fuer Theoretische Physik

    2008-07-15

    We study deeply virtual Compton scattering on a virtual pion that is emitted by a proton. Using a range of models for the generalized parton distributions of the pion, we evaluate the cross section, as well as the beam spin and beam charge asymmetries in the leading-twist approximation. Studying Compton scattering on the pion in suitable kinematics puts high demands on both beam energy and luminosity, and we find that the corresponding requirements will first be met after the energy upgrade at Jefferson Laboratory. As a by-product of our study, we construct a parameterization of pion generalized parton distributions that has a non-trivial interplay between the x and t dependence and is in good agreement with form factor data and lattice calculations. (orig.)

  5. Comparison between electron and neutron Compton scattering studies

    Directory of Open Access Journals (Sweden)

    Moreh Raymond

    2015-01-01

    Full Text Available We compare two techniques: Electron Compton Scattering (ECS and neutron Compton scattering (NCS and show that using certain incident energies, both can measure the atomic kinetic energy of atoms in molecules and solids. The information obtained is related to the Doppler broadening of nuclear levels and is very useful for deducing the widths of excited levels in many nuclei in self absorption measurements. A comparison between the atomic kinetic energies measured by the two methods on the same samples is made. Some results are also compared with calculated atomic kinetic energies obtained using the harmonic approximation where the vibrational frequencies were taken from IR/Raman optical measurements. The advantages of the ECS method are emphasized.

  6. Detection of detachments and inhomogeneities in frescos by Compton scattering

    International Nuclear Information System (INIS)

    Castellano, A.; Cesareo, R.; Buccolieri, G.; Donativi, M.; Palama, F.; Quarta, S.; De Nunzio, G.; Brunetti, A.; Marabelli, M.; Santamaria, U.

    2005-01-01

    A mobile instrument has been developed for the detection and mapping of detachments in frescos by using Compton back scattered photons. The instrument is mainly composed of a high energy X-ray tube, an X-ray detection system and a translation table. The instrument was first applied to samples simulating various detachment situations, and then transferred to the Vatican Museum to detect detachments and inhomogeneities in the stanza di Eliodoro, one of the 'Raphael's stanze'

  7. Detection of detachments and inhomogeneities in frescos by Compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Castellano, A. [Dipartimento di Scienza dei Materiali, Universita di Lecce, 73100 Lecce (Italy); INFN, Sezione di Lecce, via per Arnesano, 73100 Lecce (Italy); Cesareo, R. [Istituto di Matematica e Fisica, Universita di Sassari, 07100 Sassari (Italy) and INFN, Sezione di Cagliari, Cittadella Universitaria di Monserrato, 09042 Cagliari (Italy)]. E-mail: cesareo@uniss.it; Buccolieri, G. [Dipartimento di Scienza dei Materiali, Universita di Lecce, 73100 Lecce (Italy); INFN, Sezione di Lecce, via per Arnesano, 73100 Lecce (Italy); Donativi, M. [Dipartimento di Scienza dei Materiali, Universita di Lecce, 73100 Lecce (Italy); Palama, F. [Dipartimento di Scienza dei Materiali, Universita di Lecce, 73100 Lecce (Italy); INFN, Sezione di Lecce, via per Arnesano, 73100 Lecce (Italy); Quarta, S. [Dipartimento di Scienza dei Materiali, Universita di Lecce, 73100 Lecce (Italy); INFN, Sezione di Lecce, via per Arnesano, 73100 Lecce (Italy); De Nunzio, G. [Dipartimento di Scienza dei Materiali, Universita di Lecce, 73100 Lecce (Italy); INFN, Sezione di Lecce, via per Arnesano, 73100 Lecce (Italy); Brunetti, A. [Istituto di Matematica e Fisica, Universita di Sassari, 07100 Sassari (Italy); INFN, Sezione di Cagliari, Cittadella Universitaria di Monserrato, 09042 Cagliari (Italy); Marabelli, M. [Istituto Centrale del Restauro, P.zza S. Francesco di Paola, 00184 Rome (Italy); Santamaria, U. [Laboratori dei Musei Vaticani, Citta del Vaticano, Rome (Italy)

    2005-07-01

    A mobile instrument has been developed for the detection and mapping of detachments in frescos by using Compton back scattered photons. The instrument is mainly composed of a high energy X-ray tube, an X-ray detection system and a translation table. The instrument was first applied to samples simulating various detachment situations, and then transferred to the Vatican Museum to detect detachments and inhomogeneities in the stanza di Eliodoro, one of the 'Raphael's stanze'.

  8. Real and virtual Compton scattering: The nucleon polarizabilities

    International Nuclear Information System (INIS)

    Downie, E.J.; Fonvieille, H.

    2011-01-01

    We give an overview of low-energy Compton scattering γ (*) p → γp with a real or virtual incoming photon. These processes allow the investigation of one of the fundamental properties of the nucleon, i.e. how its internal structure deforms under an applied static electromagnetic field. Our knowledge of nucleon polarizabilities and their generalization to non-zero four-momentum transfer will be reviewed, including the presently ongoing experiments and future perspectives. (authors)

  9. Deeply virtual Compton scattering: How to test handbag dominance?

    International Nuclear Information System (INIS)

    Gousset, T.; Gousset, T.; Diehl, M.; Pire, B.; Diehl, M.; Ralston, J.P.

    1998-01-01

    We propose detailed tests of the handbag approximation in exclusive deeply virtual Compton scattering. Those tests make no use of any prejudice about parton correlations in the proton which are basically unknown objects and beyond the scope of perturbative QCD. Since important information on the proton substructure can be gained in the regime of light cone dominance we consider that such a class of tests is of special relevance. copyright 1998 American Institute of Physics

  10. Rosseland and Flux Mean Opacities for Compton Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Poutanen, Juri, E-mail: juri.poutanen@utu.fi [Tuorla Observatory, Department of Physics and Astronomy, University of Turku, Väisäläntie 20, FI-21500 Piikkiö (Finland)

    2017-02-01

    Rosseland mean opacity plays an important role in theories of stellar evolution and X-ray burst models. In the high-temperature regime, when most of the gas is completely ionized, the opacity is dominated by Compton scattering. Our aim here is to critically evaluate previous works on this subject and to compute the exact Rosseland mean opacity for Compton scattering over a broad range of temperature and electron degeneracy parameter. We use relativistic kinetic equations for Compton scattering and compute the photon mean free path as a function of photon energy by solving the corresponding integral equation in the diffusion limit. As a byproduct we also demonstrate the way to compute photon redistribution functions in the case of degenerate electrons. We then compute the Rosseland mean opacity as a function of temperature and electron degeneracy and present useful approximate expressions. We compare our results to previous calculations and find a significant difference in the low-temperature regime and strong degeneracy. We then proceed to compute the flux mean opacity in both free-streaming and diffusion approximations, and show that the latter is nearly identical to the Rosseland mean opacity. We also provide a simple way to account for the true absorption in evaluating the Rosseland and flux mean opacities.

  11. Measurements of Compton Scattered Transition Radiation at High Lorentz Factors

    CERN Document Server

    Case, Gary L.; Cherry, Michael L.; Isbert, Joachim; Mitchell, John W.; Patterson, Donald; Case, Gary L.; Cherry, Michael L.; Isbert, Joachim; Mitchell, John W.; Patterson, Donald

    2004-01-01

    X-ray transition radiation can be used to measure the Lorentz factor of relativistic particles. Standard transition radiation detectors (TRDs) typically incorporate thin plastic foil radiators and gas-filled x-ray detectors, and are sensitive up to \\gamma ~ 10^4. To reach higher Lorentz factors (up to \\gamma ~ 10^5), thicker, denser radiators can be used, which consequently produce x-rays of harder energies (>100 keV). At these energies, scintillator detectors are more efficient in detecting the hard x-rays, and Compton scattering of the x-rays out of the path of the particle becomes an important effect. The Compton scattering can be utilized to separate the transition radiation from the ionization background spatially. The use of conducting metal foils is predicted to yield enhanced signals compared to standard nonconducting plastic foils of the same dimensions. We have designed and built a Compton Scatter TRD optimized for high Lorentz factors and exposed it to high energy electrons at the CERN SPS. We pres...

  12. Beam-charge azimuthal asymmetry and deeply virtual Compton scattering

    Science.gov (United States)

    Airapetian, A.; Akopov, N.; Akopov, Z.; Amarian, M.; Andrus, A.; Aschenauer, E. C.; Augustyniak, W.; Avakian, R.; Avetissian, A.; Avetissian, E.; Bailey, P.; Balin, D.; Beckmann, M.; Belostotski, S.; Bianchi, N.; Blok, H. P.; Böttcher, H.; Borissov, A.; Borysenko, A.; Bouwhuis, M.; Brüll, A.; Bryzgalov, V.; Capiluppi, M.; Capitani, G. P.; Chen, T.; Ciullo, G.; Contalbrigo, M.; Dalpiaz, P. F.; Deconinck, W.; de Leo, R.; Demey, M.; de Nardo, L.; de Sanctis, E.; Devitsin, E.; di Nezza, P.; Dreschler, J.; Düren, M.; Ehrenfried, M.; Elalaoui-Moulay, A.; Elbakian, G.; Ellinghaus, F.; Elschenbroich, U.; Fabbri, R.; Fantoni, A.; Felawka, L.; Frullani, S.; Funel, A.; Gapienko, G.; Gapienko, V.; Garibaldi, F.; Garrow, K.; Gaskell, D.; Gavrilov, G.; Gharibyan, V.; Grebeniouk, O.; Gregor, I. M.; Hadjidakis, C.; Hafidi, K.; Hartig, M.; Hasch, D.; Hesselink, W. H. A.; Hillenbrand, A.; Hoek, M.; Holler, Y.; Hommez, B.; Hristova, I.; Iarygin, G.; Ivanilov, A.; Izotov, A.; Jackson, H. E.; Jgoun, A.; Kaiser, R.; Kinney, E.; Kisselev, A.; Kobayashi, T.; Kopytin, M.; Korotkov, V.; Kozlov, V.; Krauss, B.; Krivokhijine, V. G.; Lagamba, L.; Lapikás, L.; Laziev, A.; Lenisa, P.; Liebing, P.; Linden-Levy, L. A.; Lorenzon, W.; Lu, H.; Lu, J.; Lu, S.; Ma, B.-Q.; Maiheu, B.; Makins, N. C. R.; Mao, Y.; Marianski, B.; Marukyan, H.; Masoli, F.; Mexner, V.; Meyners, N.; Michler, T.; Mikloukho, O.; Miller, C. A.; Miyachi, Y.; Muccifora, V.; Murray, M.; Nagaitsev, A.; Nappi, E.; Naryshkin, Y.; Negodaev, M.; Nowak, W.-D.; Oganessyan, K.; Ohsuga, H.; Osborne, A.; Pickert, N.; Potterveld, D. H.; Raithel, M.; Reggiani, D.; Reimer, P. E.; Reischl, A.; Reolon, A. R.; Riedl, C.; Rith, K.; Rosner, G.; Rostomyan, A.; Rubacek, L.; Rubin, J.; Ryckbosch, D.; Salomatin, Y.; Sanjiev, I.; Savin, I.; Schäfer, A.; Schnell, G.; Schüler, K. P.; Seele, J.; Seidl, R.; Seitz, B.; Shanidze, R.; Shearer, C.; Shibata, T.-A.; Shutov, V.; Sinram, K.; Sommer, W.; Stancari, M.; Statera, M.; Steffens, E.; Steijger, J. J. M.; Stenzel, H.; Stewart, J.; Stinzing, F.; Tait, P.; Tanaka, H.; Taroian, S.; Tchuiko, B.; Terkulov, A.; Trzcinski, A.; Tytgat, M.; Vandenbroucke, A.; van der Nat, P. B.; van der Steenhoven, G.; van Haarlem, Y.; Vikhrov, V.; Vincter, M. G.; Vogel, C.; Volmer, J.; Wang, S.; Wendland, J.; Ye, Y.; Ye, Z.; Yen, S.; Zihlmann, B.; Zupranski, P.

    2007-01-01

    The first observation of an azimuthal cross section asymmetry with respect to the charge of the incoming lepton beam is reported from a study of hard exclusive electroproduction of real photons. The data have been accumulated by the HERMES experiment at DESY, in which the HERA 27.6 GeV electron or positron beam scattered off an unpolarized hydrogen gas target. The observed asymmetry is attributed to the interference between the Bethe-Heitler process and the deeply virtual Compton scattering (DVCS) process. The interference term is sensitive to DVCS amplitudes, which provide the most direct access to generalized parton distributions.

  13. Sources of the X-rays Based on Compton Scattering

    International Nuclear Information System (INIS)

    Androsov, V.; Bulyak, E.; Gladkikh, P.; Karnaukhov, I.; Mytsykov, A.; Telegin, Yu.; Shcherbakov, A.; Zelinsky, A.

    2007-01-01

    The principles of the intense X-rays generation by laser beam scattering on a relativistic electron beam are described and description of facilities assigned to produce the X-rays based on Compton scattering is presented. The possibilities of various types of such facilities are estimated and discussed. The source of the X-rays based on a storage ring with low beam energy is described in details and advantages of the sources of such type are discussed.The results of calculation and numerical simulation carried out for laser electron storage ring NESTOR that is under development in NSC KIPT show wide prospects of the accelerator facility of such type

  14. Compton scattering at finite temperature: thermal field dynamics approach

    International Nuclear Information System (INIS)

    Juraev, F.I.

    2006-01-01

    Full text: Compton scattering is a classical problem of quantum electrodynamics and has been studied in its early beginnings. Perturbation theory and Feynman diagram technique enables comprehensive analysis of this problem on the basis of which famous Klein-Nishina formula is obtained [1, 2]. In this work this problem is extended to the case of finite temperature. Finite-temperature effects in Compton scattering is of practical importance for various processes in relativistic thermal plasmas in astrophysics. Recently Compton effect have been explored using closed-time path formalism with temperature corrections estimated [3]. It was found that the thermal cross section can be larger than that for zero-temperature by several orders of magnitude for the high temperature realistic in astrophysics [3]. In our work we use a main tool to account finite-temperature effects, a real-time finite-temperature quantum field theory, so-called thermofield dynamics [4, 5]. Thermofield dynamics is a canonical formalism to explore field-theoretical processes at finite temperature. It consists of two steps, doubling of Fock space and Bogolyubov transformations. Doubling leads to appearing additional degrees of freedom, called tilded operators which together with usual field operators create so-called thermal doublet. Bogolyubov transformations make field operators temperature-dependent. Using this formalism we treat Compton scattering at finite temperature via replacing in transition amplitude zero-temperature propagators by finite-temperature ones. As a result finite-temperature extension of the Klein-Nishina formula is obtained in which differential cross section is represented as a sum of zero-temperature cross section and finite-temperature correction. The obtained result could be useful in quantum electrodynamics of lasers and for relativistic thermal plasma processes in astrophysics where correct account of finite-temperature effects is important. (author)

  15. Resonant Inverse Compton Scattering Spectra from Highly Magnetized Neutron Stars

    Science.gov (United States)

    Wadiasingh, Zorawar; Baring, Matthew G.; Gonthier, Peter L.; Harding, Alice K.

    2018-02-01

    Hard, nonthermal, persistent pulsed X-ray emission extending between 10 and ∼150 keV has been observed in nearly 10 magnetars. For inner-magnetospheric models of such emission, resonant inverse Compton scattering of soft thermal photons by ultrarelativistic charges is the most efficient production mechanism. We present angle-dependent upscattering spectra and pulsed intensity maps for uncooled, relativistic electrons injected in inner regions of magnetar magnetospheres, calculated using collisional integrals over field loops. Our computations employ a new formulation of the QED Compton scattering cross section in strong magnetic fields that is physically correct for treating important spin-dependent effects in the cyclotron resonance, thereby producing correct photon spectra. The spectral cutoff energies are sensitive to the choices of observer viewing geometry, electron Lorentz factor, and scattering kinematics. We find that electrons with energies ≲15 MeV will emit most of their radiation below 250 keV, consistent with inferred turnovers for magnetar hard X-ray tails. More energetic electrons still emit mostly below 1 MeV, except for viewing perspectives sampling field-line tangents. Pulse profiles may be singly or doubly peaked dependent on viewing geometry, emission locale, and observed energy band. Magnetic pair production and photon splitting will attenuate spectra to hard X-ray energies, suppressing signals in the Fermi-LAT band. The resonant Compton spectra are strongly polarized, suggesting that hard X-ray polarimetry instruments such as X-Calibur, or a future Compton telescope, can prove central to constraining model geometry and physics.

  16. Nonlinear Compton scattering in ultrashort laser pulses

    International Nuclear Information System (INIS)

    Mackenroth, F.; Di Piazza, A.

    2011-01-01

    A detailed analysis of the photon emission spectra of an electron scattered by a laser pulse containing only very few cycles of the carrying electromagnetic field is presented. The analysis is performed in the framework of strong-field quantum electrodynamics, with the laser field taken into account exactly in the calculations. We consider different emission regimes depending on the laser intensity, placing special emphasis on the regime of one-cycle beams and of high laser intensities, where the emission spectra depend nonperturbatively on the laser intensity. In this regime, we, in particular, present an accurate stationary phase analysis of the integrals that are shown to determine the computed emission spectra. The emission spectra show significant differences with respect to those in a long pulsed or monochromatic laser field: The emission lines obtained here are much broader, and more important, no dressing of the electron mass is observed.

  17. The Mathematical Foundations of 3D Compton Scatter Emission Imaging

    Directory of Open Access Journals (Sweden)

    T. T. Truong

    2007-01-01

    Full Text Available The mathematical principles of tomographic imaging using detected (unscattered X- or gamma-rays are based on the two-dimensional Radon transform and many of its variants. In this paper, we show that two new generalizations, called conical Radon transforms, are related to three-dimensional imaging processes based on detected Compton scattered radiation. The first class of conical Radon transform has been introduced recently to support imaging principles of collimated detector systems. The second class is new and is closely related to the Compton camera imaging principles and invertible under special conditions. As they are poised to play a major role in future designs of biomedical imaging systems, we present an account of their most important properties which may be relevant for active researchers in the field.

  18. Electronic structure of the palladium hydride studied by compton scattering

    CERN Document Server

    Mizusaki, S; Yamaguchi, M; Hiraoka, N; Itou, M; Sakurai, Y

    2003-01-01

    The hydrogen-induced changes in the electronic structure of Pd have been investigated by Compton scattering experiments associated with theoretical calculations. Compton profiles (CPs) of single crystal of Pd and beta phase hydride PdH sub x (x=0.62-0.74) have been measured along the [100], [110] and [111] directions with a momentum resolution of 0.14-0.17 atomic units using 115 keV x-rays. The theoretical Compton profiles have been calculated from the wavefunctions obtained utilizing the full potential linearized augmented plane wave method within the local density approximation for Pd and stoichiometric PdH. The experimental and the theoretical results agreed well with respect to the difference in the CPs between PdH sub x and Pd, and the anisotropy in the CPs of Pd or PdH sub x. This study provides lines of evidence that upon hydride formation the lowest valance band of Pd is largely modified due to hybridization with H 1s-orbitals and the Fermi energy is raised into the sp-band. (author)

  19. Compton Scattering of Quasi-Real Virtual Photons at LEP

    CERN Document Server

    Achard, P.; Aguilar-Benitez, M.; Alcaraz, J.; Alemanni, G.; Allaby, J.; Aloisio, A.; Alviggi, M.G.; Anderhub, H.; Andreev, Valery P.; Anselmo, F.; Arefiev, A.; Azemoon, T.; Aziz, T.; Bagnaia, P.; Bajo, A.; Baksay, G.; Baksay, L.; Baldew, S.V.; Banerjee, S.; Banerjee, Sw.; Barczyk, A.; Barillere, R.; Bartalini, P.; Basile, M.; Batalova, N.; Battiston, R.; Bay, A.; Becattini, F.; Becker, U.; Behner, F.; Bellucci, L.; Berbeco, R.; Berdugo, J.; Berges, P.; Bertucci, B.; Betev, B.L.; Biasini, M.; Biglietti, M.; Biland, A.; Blaising, J.J.; Blyth, S.C.; Bobbink, G.J.; Bohm, A.; Boldizsar, L.; Borgia, B.; Bottai, S.; Bourilkov, D.; Bourquin, M.; Braccini, S.; Branson, J.G.; Brochu, F.; Burger, J.D.; Burger, W.J.; Cai, X.D.; Capell, M.; Cara Romeo, G.; Carlino, G.; Cartacci, A.; Casaus, J.; Cavallari, F.; Cavallo, N.; Cecchi, C.; Cerrada, M.; Chamizo, M.; Chang, Y.H.; Chemarin, M.; Chen, A.; Chen, G.; Chen, G.M.; Chen, H.F.; Chen, H.S.; Chiefari, G.; Cifarelli, L.; Cindolo, F.; Clare, I.; Clare, R.; Coignet, G.; Colino, N.; Costantini, S.; de la Cruz, B.; Cucciarelli, S.; de Asmundis, R.; Deglon, P.; Debreczeni, J.; Degre, A.; Dehmelt, K.; Deiters, K.; della Volpe, D.; Delmeire, E.; Denes, P.; DeNotaristefani, F.; De Salvo, A.; Diemoz, M.; Dierckxsens, M.; Dionisi, C.; Dittmar, M.; Doria, A.; Dova, M.T.; Duchesneau, D.; Duda, M.; Echenard, B.; Eline, A.; El Hage, A.; El Mamouni, H.; Engler, A.; Eppling, F.J.; Extermann, P.; Falagan, M.A.; Falciano, S.; Favara, A.; Fay, J.; Fedin, O.; Felcini, M.; Ferguson, T.; Fesefeldt, H.; Fiandrini, E.; Field, J.H.; Filthaut, F.; Fisher, P.H.; Fisher, W.; Fisk, I.; Forconi, G.; Freudenreich, K.; Furetta, C.; Galaktionov, Iouri; Ganguli, S.N.; Garcia-Abia, Pablo; Gataullin, M.; Gentile, S.; Giagu, S.; Gong, Z.F.; Grenier, Gerald Jean; Grimm, O.; Gruenewald, M.W.; Guida, M.; Gupta, V.K.; Gurtu, A.; Gutay, L.J.; Haas, D.; Hatzifotiadou, D.; Hebbeker, T.; Herve, Alain; Hirschfelder, J.; Hofer, H.; Hohlmann, M.; Holzner, G.; Hou, S.R.; Jin, B.N.; Jindal, P.; Jones, Lawrence W.; de Jong, P.; Josa-Mutuberria, I.; Kaur, M.; Kienzle-Focacci, M.N.; Kim, J.K.; Kirkby, Jasper; Kittel, W.; Klimentov, A.; Konig, A.C.; Kopal, M.; Koutsenko, V.; Kraber, M.; Kraemer, R.W.; Kruger, A.; Kunin, A.; Ladron de Guevara, P.; Laktineh, I.; Landi, G.; Lebeau, M.; Lebedev, A.; Lebrun, P.; Lecomte, P.; Lecoq, P.; Le Coultre, P.; Le Goff, J.M.; Leiste, R.; Levtchenko, M.; Levtchenko, P.; Li, C.; Likhoded, S.; Lin, C.H.; Lin, W.T.; Linde, F.L.; Lista, L.; Liu, Z.A.; Lohmann, W.; Longo, E.; Lu, Y.S.; Luci, C.; Luminari, L.; Lustermann, W.; Ma, W.G.; Malgeri, L.; Malinin, A.; Mana, C.; Mans, J.; Martin, J.P.; Marzano, F.; Mazumdar, K.; McNeil, R.R.; Mele, S.; Merola, L.; Meschini, M.; Metzger, W.J.; Mihul, A.; Milcent, H.; Mirabelli, G.; Mnich, J.; Mohanty, G.B.; Muanza, G.S.; Muijs, A.J.M.; Musicar, B.; Musy, M.; Nagy, S.; Natale, S.; Napolitano, M.; Nessi-Tedaldi, F.; Newman, H.; Nisati, A.; Novak, T.; Kluge, Hannelies; Ofierzynski, R.; Organtini, G.; Pal, I.; Palomares, C.; Paolucci, P.; Paramatti, R.; Passaleva, G.; Patricelli, S.; Paul, Thomas Cantzon; Pauluzzi, M.; Paus, C.; Pauss, F.; Pedace, M.; Pensotti, S.; Perret-Gallix, D.; Piccolo, D.; Pierella, F.; Pioppi, M.; Piroue, P.A.; Pistolesi, E.; Plyaskin, V.; Pohl, M.; Pojidaev, V.; Pothier, J.; Prokofiev, D.; Rahal-Callot, G.; Rahaman, Mohammad Azizur; Raics, P.; Raja, N.; Ramelli, R.; Rancoita, P.G.; Ranieri, R.; Raspereza, A.; Razis, P.; Ren, D.; Rescigno, M.; Reucroft, S.; Riemann, S.; Riles, Keith; Roe, B.P.; Romero, L.; Rosca, A.; Rosemann, C.; Rosenbleck, C.; Rosier-Lees, S.; Roth, Stefan; Rubio, J.A.; Ruggiero, G.; Rykaczewski, H.; Sakharov, A.; Saremi, S.; Sarkar, S.; Salicio, J.; Sanchez, E.; Schafer, C.; Schegelsky, V.; Schmidt-Kaerst, S.; Schopper, H.; Schotanus, D.J.; Sciacca, C.; Servoli, L.; Shevchenko, S.; Shivarov, N.; Shoutko, V.; Shumilov, E.; Shvorob, A.; Son, D.; Souga, C.; Spillantini, P.; Steuer, M.; Stickland, D.P.; Stoyanov, B.; Straessner, A.; Sudhakar, K.; Sultanov, G.; Sun, L.Z.; Sushkov, S.; Suter, H.; Swain, J.D.; Szillasi, Z.; Tang, X.W.; Tarjan, P.; Tauscher, L.; Taylor, L.; Tellili, B.; Teyssier, D.; Timmermans, Charles; Ting, Samuel C.C.; Ting, S.M.; Tonwar, S.C.; Toth, J.; Tully, C.; Tung, K.L.; Ulbricht, J.; Valente, E.; Van de Walle, R.T.; Vasquez, R.; Veszpremi, V.; Vesztergombi, G.; Vetlitsky, I.; Viertel, G.; Villa, S.; Vivargent, M.; Vlachos, S.; Vodopianov, I.; Vogel, H.; Vogt, H.; Vorobiev, I.; Vorobyov, A.A.; Wadhwa, M.; Wang, Q.; Wang, X.L.; Wang, Z.M.; Weber, M.; Wynhoff, S.; Xia, L.; Xu, Z.Z.; Yamamoto, J.; Yang, B.Z.; Yang, H.J.; Yeh, S.C.; Zalite, An.; Zhang, Z.P.; Zhao, J.; Zhu, G.Y.; Zhu, R.Y.; Zhuang, H.L.; Zichichi, A.; Zimmermann, B.; Zoller, M.

    2005-01-01

    Compton scattering of quasi-real virtual photons, gamma e+- -> gamma e+-, is studied with 0.6fb-1 of data collected by the L3 detector at the LEP e+e- collider at centre-of-mass energies root(s')=189-209GeV. About 4500 events produced by the interaction of virtual photons emitted by e+- of one beam with e-+ of the opposite beam are collected for effective centre-of-mass energies of the photon-electron and photon-positron systems in the range from root(s')= 35GeV up to root(s')=175GeV, the highest energy at which Compton scattering was ever probed. The cross sections of the gamma e+- -> gamma e+- process as a function of root(s') and of the rest-frame scattering angle are measured, combined with previous L3 measurements down to root(s')~20GeV, and found to agree with the QED expectations.

  20. Kharkov X-ray Generator Based On Compton Scattering

    International Nuclear Information System (INIS)

    Shcherbakov, A.; Zelinsky, A.; Mytsykov, A.; Gladkikh, P.; Karnaukhov, I.; Lapshin, V.; Telegin, Y.; Androsov, V.; Bulyak, E.; Botman, J.I.M.; Tatchyn, R.; Lebedev, A.

    2004-01-01

    Nowadays X-ray sources based on storage rings with low beam energy and Compton scattering of intense laser beams are under development in several laboratories. An international cooperative project of an advanced X-ray source of this type at the Kharkov Institute of Physics and Technology (KIPT) is described. The status of the project is reviewed. The design lattice of the storage ring and calculated X-ray beam parameters are presented. The results of numerical simulation carried out for proposed facility show a peak spectral X-ray intensity of about 1014 can be produced

  1. Design Study for Direction Variable Compton Scattering Gamma Ray

    Science.gov (United States)

    Kii, T.; Omer, M.; Negm, H.; Choi, Y. W.; Kinjo, R.; Yoshida, K.; Konstantin, T.; Kimura, N.; Ishida, K.; Imon, H.; Shibata, M.; Shimahashi, K.; Komai, T.; Okumura, K.; Zen, H.; Masuda, K.; Hori, T.; Ohgaki, H.

    2013-03-01

    A monochromatic gamma ray beam is attractive for isotope-specific material/medical imaging or non-destructive inspection. A laser Compton scattering (LCS) gamma ray source which is based on the backward Compton scattering of laser light on high-energy electrons can generate energy variable quasi-monochromatic gamma ray. Due to the principle of the LCS gamma ray, the direction of the gamma beam is limited to the direction of the high-energy electrons. Then the target object is placed on the beam axis, and is usually moved if spatial scanning is required. In this work, we proposed an electron beam transport system consisting of four bending magnets which can stick the collision point and control the electron beam direction, and a laser system consisting of a spheroidal mirror and a parabolic mirror which can also stick the collision point. Then the collision point can be placed on one focus of the spheroid. Thus gamma ray direction and collision angle between the electron beam and the laser beam can be easily controlled. As the results, travelling direction of the LCS gamma ray can be controlled under the limitation of the beam transport system, energy of the gamma ray can be controlled by controlling incident angle of the colliding beams, and energy spread can be controlled by changing the divergence of the laser beam.

  2. Observation of redshifting and harmonic radiation in inverse Compton scattering

    Science.gov (United States)

    Sakai, Y.; Pogorelsky, I.; Williams, O.; O'Shea, F.; Barber, S.; Gadjev, I.; Duris, J.; Musumeci, P.; Fedurin, M.; Korostyshevsky, A.; Malone, B.; Swinson, C.; Stenby, G.; Kusche, K.; Babzien, M.; Montemagno, M.; Jacob, P.; Zhong, Z.; Polyanskiy, M.; Yakimenko, V.; Rosenzweig, J.

    2015-06-01

    Inverse Compton scattering of laser photons by ultrarelativistic electron beam provides polarized x- to γ -ray pulses due to the Doppler blueshifting. Nonlinear electrodynamics in the relativistically intense linearly polarized laser field changes the radiation kinetics established during the Compton interaction. These are due to the induced figure-8 motion, which introduces an overall redshift in the radiation spectrum, with the concomitant emission of higher order harmonics. To experimentally analyze the strong field physics associated with the nonlinear electron-laser interaction, clear modifications to the angular and wavelength distributions of x rays are observed. The relativistic photon wave field is provided by the ps CO2 laser of peak normalized vector potential of 0.5 laser [M. Babzien et al., Phys. Rev. Lett. 96, 054802 (2006)]. The angular spectral characteristics are revealed using K -, L -edge, and high energy attenuation filters. The observation indicates existence of the electrons' longitudinal motion through frequency redshifting understood as the mass shift effect. Thus, the 3rd harmonic radiation has been observed containing on-axis x-ray component that is directly associated with the induced figure-8 motion. These are further supported by an initial evidence of off-axis 2nd harmonic radiation produced in a circularly polarized laser wave field. Total x-ray photon number per pulse, scattered by 65 MeV electron beam of 0.3 nC, at the interaction point is measured to be approximately 109 .

  3. Compton scattering from nuclei and photo-absorption sum rules

    International Nuclear Information System (INIS)

    Gorchtein, Mikhail; Hobbs, Timothy; Londergan, J. Timothy; Szczepaniak, Adam P.

    2011-01-01

    We revisit the photo-absorption sum rule for real Compton scattering from the proton and from nuclear targets. In analogy with the Thomas-Reiche-Kuhn sum rule appropriate at low energies, we propose a new 'constituent quark model' sum rule that relates the integrated strength of hadronic resonances to the scattering amplitude on constituent quarks. We study the constituent quark model sum rule for several nuclear targets. In addition, we extract the α=0 pole contribution for both proton and nuclei. Using the modern high-energy proton data, we find that the α=0 pole contribution differs significantly from the Thomson term, in contrast with the original findings by Damashek and Gilman.

  4. Implicit numerical method for Compton scattering energy exchange between electrons and non-Planckian radiation

    International Nuclear Information System (INIS)

    Winslow, A.M.

    1975-01-01

    The multi-frequency grey method is extended to include Compton scattering. In this way one arrives at an expression for the total Compton scattering energy exchange rate, which, for a Planckian radiation field, reduces to a well known formula. 15 references, 5 graphs

  5. The electron beam dynamics simulation in the laser-electron storage ring involving compton and intrabeam scattering

    International Nuclear Information System (INIS)

    Gladkikh, P.I.; Telegin, Yu.N.; Karnaukhov, I.M.

    2002-01-01

    The feasibility of the development of intense X-ray sources based on Compton scattering in laser-electron storage rings is discussed. The results of the electron beam dynamics simulation involving Compton and intrabeam scattering are presented

  6. The electron beam dynamics simulation in the laser-electron storage ring involving compton and intrabeam scattering

    CERN Document Server

    Gladkikh, P I; Karnaukhov, I M

    2002-01-01

    The feasibility of the development of intense X-ray sources based on Compton scattering in laser-electron storage rings is discussed. The results of the electron beam dynamics simulation involving Compton and intrabeam scattering are presented.

  7. Analysis of the factors that affect photon counts in Compton scattering.

    Science.gov (United States)

    Luo, Guang; Xiao, Guangyu

    2014-10-30

    Compton scattering has been applied in a variety of fields. The factors that affect Compton scattering have been studied extensively in the literature. However, the factors that affect the measured photon counts in Compton scattering are rarely considered. In this paper, we make a detailed discussion on those factors. First, Compton scattering experiments of some alloy series and powder mixture series are explored. Second, the electron density is researched in terms of atom and lattice constants. Third, the factor of attenuation coefficient is discussed. And then, the active degree of electrons is discussed based on the DFT theory. Lastly, the conclusions are made, that the factors affecting Compton scattering photon counts include mainly electron number density, attenuation coefficient and active degree of electrons. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Deeply virtual compton scattering at 6 GeV

    International Nuclear Information System (INIS)

    Berthot, J.; Chen, J.P.; Chudakov, E.

    2000-01-01

    We propose a measurement of the Deep Virtual Compton Scattering process (DVCS) ep → epγ in Hall A at Jefferson Lab with a 6 GeV beam. We are able to explore the onset of Q 2 scaling, by measuring a beam helicity asymmetry for Q 2 ranging from 1.5 to 2.5 GeV 2 at x B ∼0.35. At this kinematics, the asymmetry is dominated by the DVCS - Bethe-Heitler (BH) interference, which is proportional to the imaginary part of the DVCS amplitude amplified by the full magnitude of the BH amplitude. The imaginary part of the DVCS amplitude is expected to scale early. Indeed, the imaginary part of the forward Compton amplitude measured in deep inelastic scattering (via the optical theorem) scales at Q 2 as low as 1 GeV 2 . If the scaling regime is reached, we will make an 8% measurement of the skewed parton distributions (SPD) contributing to the DVCS amplitude. Also, this experiment allows us to separately estimate the size of the higher-twist effects, since they are only suppressed by an additional factor 1/Q compared to the leading-twist term, and have a different angular dependence. We use a polarized electron beam and detect the scattered electron in the HRSe, the real photon in an electromagnetic calorimeter (under construction) and the recoil proton in a shielded scintillator array (to be constructed). This allows as to determine the difference in cross-sections for electrons of opposite helicities. This observable is directly linked to the SPD's. We estimate that 25 days of beam (600 hours) are needed to achieve this goal. (authors)

  9. High-energy scaling of Compton scattering light sources

    Directory of Open Access Journals (Sweden)

    F. V. Hartemann

    2005-10-01

    Full Text Available No monochromatic (Δω_{x}/ω_{x}10^{20}   photons/(mm^{2}×mrad^{2}×s×0.1%   bandwidth], tunable light sources currently exist above 100 keV. Important applications that would benefit from such new hard x-ray and γ-ray sources include the following: nuclear resonance fluorescence spectroscopy and isotopic imaging, time-resolved positron annihilation spectroscopy, and MeV flash radiography. In this paper, the peak brightness of Compton scattering light sources is derived for head-on collisions and found to scale quadratically with the normalized energy, γ; inversely with the electron beam duration, Δτ, and the square of its normalized emittance, ε; and linearly with the bunch charge, eN_{e}, and the number of photons in the laser pulse, N_{γ}:   B[over ^]_{x}∝γ^{2}N_{e}N_{γ}/ε^{2}Δτ. This γ^{2} scaling shows that for low normalized emittance electron beams (1 nC, 1  mm·mrad, 100  MeV, and tabletop laser systems (1–10   J, 5 ps the x-ray peak brightness can exceed 10^{23}   photons/(mm^{2}×mrad^{2}×s×0.1%   bandwidth near ℏω_{x}=1   MeV; this is confirmed by three-dimensional codes that have been benchmarked against Compton scattering experiments performed at Lawrence Livermore National Laboratory. The interaction geometry under consideration is head-on collisions, where the x-ray flash duration is shown to be equal to that of the electron bunch, and which produce the highest peak brightness for compressed electron beams. Important nonlinear effects, including spectral broadening, are also taken into account in our analysis; they show that there is an optimum laser pulse duration in this geometry, of the order of a few picoseconds, in sharp contrast with the initial approach to laser-driven Compton scattering sources where femtosecond laser systems were thought to be mandatory. The analytical expression for the peak on-axis brightness derived here is a powerful tool to

  10. Laser propagation and compton scattering in parabolic plasma channel

    CERN Document Server

    Dongguo, L; Yokoya, K; Hirose, T

    2003-01-01

    A Gaussian laser beam propagating in a parabolic plasma channel is discussed in this paper. For a weak laser, plasma density perturbation induced by interaction between the laser field and plasma is very small, the refractive index can be assumed to be constant with respect to time variable. For a parabolic plasma channel, through the static propagation equation, we obtain an analytical solution of the profile function of the Gaussian laser beam for an unmatched case and give the general condition for the matched case. As the laser intensity increases, an effect due to strong laser fields is included. We discuss how to design and select the distribution of plasma density for a certain experiment in which a plasma channel is utilized to guide a laser beam. The number of scattered photons (X-rays) generated through Compton backscattering in a plasma channel is discussed. (author)

  11. Deeply virtual compton scattering in color dipole formalism

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Magno V.T. [Universidade Federal do Pampa (UNIPAMPA), Bage, RS (Brazil)

    2007-06-15

    In this contribution we summarize recent investigations on the Deeply Virtual Compton Scattering (DVCS) within the color dipole approach. The color dipole cross section is implemented through the phenomenological saturation model. The role played by its QCD evolution and skewedness effects in the DVCS cross section are discussed. The results are compared with the recent H1 and ZEUS Collaborations data. The skewing factor, defined as the ratio of the imaginary parts of the amplitudes Im A({gamma}* p {yields} {gamma}* p)/ Im A({gamma}* p {yields} {gamma} p) can be extracted from the data using recent DVCS and the inclusive inelastic cross section measurements at DESY-HERA. We report on this experimental extraction and compare the results to the theoretical predictions for NLO QCD and the color dipole approach. (author)

  12. Multiple scattering corrections for density profile unfolding from Compton scattering signals in reflection geometry

    International Nuclear Information System (INIS)

    Fernandez, Jorge E.; Badiali, Marco; Guidetti, Alessandro; Scot, Viviana

    2007-01-01

    Recently, a mathematical procedure was reported to unfold the density profile of wood panels from the measurement of the integrated scatter signal that contains prevalently the Compton component. An experimental device (patent claimed) has been used for these measurements. It uses reflection geometry to maximize the Compton signal. The influence of multiple scattering (MS) is not negligible as has been estimated using the Monte Carlo code MCSHAPE3D. However, Monte Carlo computations are time consuming. Therefore, in practice, the MS correction is computed off-line for few thicknesses of the specimen assuming known composition and density. Then, an original 2D interpolation algorithm is used to apply the MS correction to an arbitrary thickness scatterer, in order to improve the precision of the unfolded density profile in real time at the production line. The MS corrected density profiles are in good agreement with direct measurements performed with other means

  13. Observation of redshifting and harmonic radiation in inverse Compton scattering

    Directory of Open Access Journals (Sweden)

    Y. Sakai

    2015-06-01

    Full Text Available Inverse Compton scattering of laser photons by ultrarelativistic electron beam provides polarized x- to γ-ray pulses due to the Doppler blueshifting. Nonlinear electrodynamics in the relativistically intense linearly polarized laser field changes the radiation kinetics established during the Compton interaction. These are due to the induced figure-8 motion, which introduces an overall redshift in the radiation spectrum, with the concomitant emission of higher order harmonics. To experimentally analyze the strong field physics associated with the nonlinear electron-laser interaction, clear modifications to the angular and wavelength distributions of x rays are observed. The relativistic photon wave field is provided by the ps CO_{2} laser of peak normalized vector potential of 0.5scattered by 65 MeV electron beam of 0.3 nC, at the interaction point is measured to be approximately 10^{9}.

  14. Compton-scatter tissue densitometry: calculation of single and multiple scatter photon fluences

    International Nuclear Information System (INIS)

    Battista, J.J.; Bronskill, M.J.

    1978-01-01

    The accurate measurement of in vivo electron densities by the Compton-scatter method is limited by attenuations and multiple scattering in the patient. Using analytic and Monte Carlo calculation methods, the Clarke tissue density scanner has been modelled for incident monoenergetic photon energies from 300 to 2000 keV and for mean scattering angles of 30 to 130 degrees. For a single detector focussed to a central position in a uniform water phantom (25 x 25 x 25 cm 3 ) it has been demonstrated that: (1) Multiple scatter contamination is an inherent limitation of the Compton-scatter method of densitometry which can be minimised, but not eliminated, by improving the energy resolution of the scattered radiation detector. (2) The choice of the incident photon energy is a compromise between the permissible radiation dose to the patient and the tolerable level of multiple scatter contamination. For a mean scattering angle of 40 degrees, the intrinsic multiple-single scatter ratio decreases from 64 to 35%, and the radiation dose (per measurement) increases from 1.0 to 4.1 rad, as the incident photon energy increases from 300 to 2000 keV. These doses apply to a sampled volume of approximately 0.3 cm 3 and an electron density precision of 0.5%. (3) The forward scatter densitometer configuration is optimum, minimising both the dose and the multiple scatter contamination. For an incident photon energy of 1250 keV, the intrinsic multiple-single scatter ratio reduces from 122 to 27%, and the dose reduces from 14.3 to 1.2 rad, as the mean scattering angle decreases from 130 to 30 degrees. These calculations have been confirmed by experimental measurements. (author)

  15. Use of implicit Monte Carlo radiation transport with hydrodynamics and compton scattering

    International Nuclear Information System (INIS)

    Fleck, J.A. Jr.

    1971-03-01

    It is shown that the combination of implicit radiation transport and hydrodynamics, Compton scattering, and any other energy transport can be simply carried out by a ''splitting'' procedure. Contributions to material energy exchange can be reckoned separately for hydrodynamics, radiation transport without scattering, Compton scattering, plus any other possible energy exchange mechanism. The radiation transport phase of the calculation would be implicit, but the hydrodynamics and Compton portions would not, leading to possible time step controls. The time step restrictions which occur on radiation transfer due to large Planck mean absorption cross-sections would not occur

  16. Hadronic weak charges and parity-violating forward Compton scattering

    Science.gov (United States)

    Gorchtein, Mikhail; Spiesberger, Hubert

    2016-11-01

    Background: Parity-violating elastic electron-nucleon scattering at low momentum transfer allows one to access the nucleon's weak charge, the vector coupling of the Z -boson to the nucleon. In the Standard Model and at tree level, the weak charge of the proton is related to the weak mixing angle and accidentally suppressed, QWp ,tree=1 -4 sin2θW≈0.07 . Modern experiments aim at extracting QWp at ˜1 % accuracy. Similarly, parity nonconservation in atoms allows to access the weak charge of atomic nuclei. Purpose: We consider a novel class of radiative corrections due to the exchange of two photons, with parity violation in the hadronic/nuclear system. These corrections are prone to long-range interactions and may affect the extraction of sin2θW from the experimental data at the relevant level of precision. Methods: The two-photon exchange contribution to the parity-violating electron-proton scattering amplitude is studied in the framework of forward dispersion relations. We address the general properties of the parity-violating forward Compton scattering amplitude and use relativistic chiral perturbation theory to provide the first field-theoretical proof that it obeys a superconvergence relation. Results: We show that the significance of this new correction increases with the beam energy in parity-violating electron scattering, but the superconvergence relation protects the formal definition of the weak charge as a limit at zero-momentum transfer and zero energy. We evaluate the new correction in a hadronic model with pion loops and the Δ (1232 ) resonance, supplemented with a high-energy contribution. For the kinematic conditions of existing and upcoming experiments we show that two-photon exchange corrections with hadronic or nuclear parity violation do not pose a problem for the interpretation of the data in terms of the weak mixing angle at the present level of accuracy. Conclusions: Two-photon exchange in presence of hadronic or nuclear parity violation

  17. An undergraduate laboratory study of the polarisation of annihilation photons using Compton scattering

    OpenAIRE

    Knights, Patrick; Ryburn, Finlay; Tungate, Garry; Nikolopoulos, Konstantinos

    2018-01-01

    An experiment for the advanced undergraduate laboratory which allows students to study the effect of photon polarisation in Compton scattering and to explore q\\ uantum entanglement is described. The quantum entangled photons are produced through electron-positron annihilation in the $S$-state, and their polarisations a\\ re analysed using the Compton scattering cross-section dependence on the photon polarisation. The equipment necessary for this experiment is available at a typ\\ ical undergrad...

  18. Compton energy-absorption scattering cross-sections for H, C, N, O, P, Ca and assessment of doppler broadening

    CERN Document Server

    Rao, D V; Brunetti, A; Gigante, G E

    2003-01-01

    Total Compton, individual shell and Compton energy-absorption scattering cross-sections are evaluated in the energy region 0.005 to 10 MeV for H, C. N, O. P and Ca. Compton energy absorption cross-sections deviate numerically with available values. The cause of the numerical discrepancies are not fully understood but can be attributed to Doppler broadening of the Compton scattered photons through a given angle. (authors)

  19. Virtual Compton Scattering off a Spinless Target in the AdS/QCD correspondence

    Energy Technology Data Exchange (ETDEWEB)

    Wallon, Samuel [Laboratoire de Physique Theorique d' Orsay - LPT, Bat. 210, Univ. Paris-Sud 11, 91405 Orsay Cedex (France); Marquet, Cyrille [IPhT - Institut de Physique Theorique, Orme des Merisiers bat. 774, PC 136, CEA/DSM/IPhT, CEA/Saclay, F-91191 Gif-sur-Yvette Cedex (France); Roiesnel, Claude [Centre de Physique Theorique - CPHT, UMR 7644, Ecole Polytechnique, Bat. 6, RDC, F91128 Palaiseau Cedex (France)

    2010-07-01

    We study the doubly virtual Compton scattering off a spinless target {gamma}* P {yields} {gamma}* P' within the Anti-de Sitter(AdS)/QCD formalism. We find that the general structure allowed by the Lorentz invariance and gauge invariance of the Compton amplitude is not easily reproduced with the standard recipes of the AdS/QCD correspondence. In the soft-photon regime, where the semi-classical approximation is supposed to apply best, we show that the measurements of the electric and magnetic polarizabilities of a target like the charged pion in real Compton scattering, can already serve as stringent tests. (author)

  20. Deeply virtual Compton scattering off unpolarised deuterium at HERMES

    International Nuclear Information System (INIS)

    Hill, Gordon D.

    2008-08-01

    The HERMES experiment was a forward angle spectrometer on the HERA storage ring at DESY, Hamburg, Germany. HERMES successfully increased understanding of the ''spin puzzle'', the spin structure of the nucleon, by providing high precision measurements of ΔΣ in the Quark Parton Model, the fraction of the spin carried by the current quarks. Following the link of another piece of the puzzle, the orbital angular momentum of quarks and gluons, to the Generalised Parton Distribution (GPD) theoretical framework, HERMES focused on measurements of the Deeply Virtual Compton Scattering (DVCS) process. These measurements are sensitive to GPDs, allowing further experimental constraints to be made on the components of nucleon spin. In the Winter shutdown period 2005-2006 HERMES was upgraded with a Recoil Detector in the target region. This allowed the experiment to make exclusive measurements of the DVCS process for the rst time, reducing background and increasing the resolution of various kinematic variables. The method for reconstructing particle tracks in the inhomogeneous magnetic eld is investigated here. DVCS o a deuterium target is measured with all available data prior to the installation of the Recoil Detector. A comparison is made to currently available models of spin-(1)/(2) GPDs. This analysis has been approved for publication by the HERMES collaboration. The data is further employed in an investigation of a model dependent constraint of the total angular momentum of up and down quarks in the nucleon. (orig.)

  1. Deeply virtual Compton scattering off unpolarised deuterium at HERMES

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Gordon D.

    2008-10-15

    The HERMES experiment was a forward angle spectrometer on the HERA storage ring at DESY, Hamburg, Germany. HERMES successfully increased understanding of the ''spin puzzle'', the spin structure of the nucleon, by providing high precision measurements of {delta}{sigma} in the Quark Parton Model, the fraction of the spin carried by the current quarks. Following the link of another piece of the puzzle, the orbital angular momentum of quarks and gluons, to the Generalised Parton Distribution (GPD) theoretical framework, HERMES focused on measurements of the Deeply Virtual Compton Scattering (DVCS) process. These measurements are sensitive to GPDs, allowing further experimental constraints to be made on the components of nucleon spin. In the Winter shutdown period 2005-2006 HERMES was upgraded with a Recoil Detector in the target region. This allowed the experiment to make exclusive measurements of the DVCS process for the rst time, reducing background and increasing the resolution of various kinematic variables. The method for reconstructing particle tracks in the inhomogeneous magnetic eld is investigated here. DVCS o a deuterium target is measured with all available data prior to the installation of the Recoil Detector. A comparison is made to currently available models of spin-(1)/(2) GPDs. This analysis has been approved for publication by the HERMES collaboration. The data is further employed in an investigation of a model dependent constraint of the total angular momentum of up and down quarks in the nucleon. (orig.)

  2. Wide Angle Compton Scattering within the SCET factorization Framework

    Directory of Open Access Journals (Sweden)

    Kivel Nikolay

    2016-01-01

    Full Text Available Existing data for the electromagnetic proton form factors and for the cross section of the wide angle Compton scattering (WACS show that the hard two-gluon exchange mechanism (collinear factorization is still not applicable in the kinematical region where Mandelstam variables s ~ −t ~ −u are about few GeV2. On the other hand these observables can be described in phenomenological models where spectator quarks are soft which assumes a large contribution due to the soft-overlap mechanism. It turns out that the simple QCD factorization picture is not complete and must also include the soft-overlap contribution which can be described as a certain matrix element in the soft collinear effective theory (SCET. Then the leading power contribution to WACS amplitude is described as a sum of the hard- and soft-spectator contributions. The existing experimental data allows one to check certain conclusions based on the assumption about dominant role of the soft-spectator mechanism.

  3. Deeply virtual Compton scattering off longitudinally polarised protons at HERMES

    International Nuclear Information System (INIS)

    Mahon, David Francis

    2010-03-01

    This thesis details the simultaneous extraction of three polarisation-dependent asymmetries in the distribution of real photons from the ep→epγ interaction and its indistinguishable deeply virtual Compton scattering and Bethe-Heitler processes at the HERMES fixed-target experiment at Desy. The data analysed were taken using a longitudinally polarised 27.57 GeV positron beam incident on a longitudinally polarised hydrogen gas target. The extracted asymmetries include two single-spin asymmetries A UL and A LU which depend on the polarisation of the target and beam respectively, averaged over all other polarisation states. The double-spin asymmetry A LL dependent on the product of the beam and target polarisations is extracted for the first time. The asymmetry amplitudes extracted relate to combinations of Generalised Parton Distributions (GPDs), predominantly H and H. The extracted amplitudes are presented across the HERMES kinematic range alongside theoretical predictions from a GPD model based on double distributions. Large sin φ and cos(0φ) amplitudes are observed for A UL and A LL respectively, with an unexpectedly large sin(2φ) amplitude for A UL . The results for the A UL and A LL asymmetries are broadly compatible with theory predictions, and the extracted A LU amplitudes are compatible with HERMES results extracted from a significantly larger data set. It is foreseen that these results will form input to future global data-based GPD models which aim to provide a better understanding of GPDs. (orig.)

  4. Beam Diagnostics for Laser Undulator Based on Compton Backward Scattering

    CERN Document Server

    Kuroda, R

    2005-01-01

    A compact soft X-ray source is required in various research fields such as material and biological science. The laser undulator based on Compton backward scattering has been developed as a compact soft X-ray source for the biological observation at Waseda University. It is performed in a water window region (250eV - 500 eV) using the interaction between 1047 nm Nd:YLF laser (10ps FWHM) and about 5 MeV high quality electron beam (10ps FWHM) generated from rf gun system. The range of X-ray energy in the water window region has K-shell absorption edges of Oxygen, Carbon and Nitrogen, which mainly constitute of living body. Since the absorption coefficient of water is much smaller than the protein's coefficient in this range, a dehydration of the specimens is not necessary. To generate the soft X-ray pulse stably, the electron beam diagnostics have been developed such as the emittance measurement using double slit scan technique, the bunch length measurement using two frequency analysis technique. In this confere...

  5. Study of Compton scattering influence in cardiac SPECT images

    International Nuclear Information System (INIS)

    Munhoz, A.C.L.; Abe, R.; Zanardo, E.L.; Robilotta, C.C.

    1992-01-01

    The reduction effect from Compton fraction in the quality of and image is evaluated, with two ways of acquisition data: one, with the window of energetic analyser dislocated over the photopeak and the other, with two windows, one over the Compton contribution and the other, placed in the center over the photopeak. (C.G.C.)

  6. Deeply virtual Compton scattering off longitudinally polarised protons at HERMES

    Energy Technology Data Exchange (ETDEWEB)

    Mahon, David Francis

    2010-06-15

    This thesis details the simultaneous extraction of three polarisation-dependent asymmetries in the distribution of real photons from the ep{yields}ep{gamma} interaction and its indistinguishable deeply virtual Compton scattering and Bethe-Heitler processes at the HERMES fixed-target experiment at Desy. The data analysed were taken using a longitudinally polarised 27.57 GeV positron beam incident on a longitudinally polarised hydrogen gas target. The extracted asymmetries include two single-spin asymmetries A{sub UL} and A{sub LU} which depend on the polarisation of the target and beam respectively, averaged over all other polarisation states. The double-spin asymmetry A{sub LL} dependent on the product of the beam and target polarisations is extracted for the first time. The asymmetry amplitudes extracted relate to combinations of Generalised Parton Distributions (GPDs), predominantly H and H. The extracted amplitudes are presented across the HERMES kinematic range alongside theoretical predictions from a GPD model based on double distributions. Large sin {phi} and cos(0{phi}) amplitudes are observed for A{sub UL} and A{sub LL} respectively, with an unexpectedly large sin(2{phi}) amplitude for A{sub UL}. The results for the A{sub UL} and A{sub LL} asymmetries are broadly compatible with theory predictions, and the extracted A{sub LU} amplitudes are compatible with HERMES results extracted from a significantly larger data set. It is foreseen that these results will form input to future global data-based GPD models which aim to provide a better understanding of GPDs. (orig.)

  7. Development of TOF-PET using Compton scattering by plastic scintillators

    International Nuclear Information System (INIS)

    Kuramoto, M.; Nakamori, T.; Kimura, S.; Gunji, S.; Takakura, M.; Kataoka, J.

    2017-01-01

    We propose a time-of-flight (TOF) technique using plastic scintillators which have fast decay time of a few ns for positron emission tomography (PET). While the photoelectric absorption probability of the plastic for 511 keV gamma rays are extremely low due to its small density and effective atomic number, the cross section of Compton scattering is comparable to that of absorption by conventional inorganic scintillators. We thus propose TOF-PET using Compton scattering with plastic scintillators (Compton-PET), and performed fundamental experiments towards exploration of the Compton-PET capability. We demonstrated that the plastic scintillators achieved the better time resolution in comparison to LYSO(Ce) and GAGG(Ce) scintillators. In addition we evaluated the depth-of-interaction resolving capability with the plastic scintillators.

  8. Development of TOF-PET using Compton scattering by plastic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Kuramoto, M., E-mail: kuramoto@maxwell.kj.yamagata-u.ac.jp [Yamagata University, Kojirakawa 1-4-12, Yamagata 990-8560 (Japan); Nakamori, T., E-mail: nakamori@maxwell.kj.yamagata-u.ac.jp [Yamagata University, Kojirakawa 1-4-12, Yamagata 990-8560 (Japan); Kimura, S.; Gunji, S.; Takakura, M. [Yamagata University, Kojirakawa 1-4-12, Yamagata 990-8560 (Japan); Kataoka, J. [Waseda University, Okubo 3-4-1, Shinjuku, Tokyo 169-8555 (Japan)

    2017-02-11

    We propose a time-of-flight (TOF) technique using plastic scintillators which have fast decay time of a few ns for positron emission tomography (PET). While the photoelectric absorption probability of the plastic for 511 keV gamma rays are extremely low due to its small density and effective atomic number, the cross section of Compton scattering is comparable to that of absorption by conventional inorganic scintillators. We thus propose TOF-PET using Compton scattering with plastic scintillators (Compton-PET), and performed fundamental experiments towards exploration of the Compton-PET capability. We demonstrated that the plastic scintillators achieved the better time resolution in comparison to LYSO(Ce) and GAGG(Ce) scintillators. In addition we evaluated the depth-of-interaction resolving capability with the plastic scintillators.

  9. Development of TOF-PET using Compton scattering by plastic scintillators

    Science.gov (United States)

    Kuramoto, M.; Nakamori, T.; Kimura, S.; Gunji, S.; Takakura, M.; Kataoka, J.

    2017-02-01

    We propose a time-of-flight (TOF) technique using plastic scintillators which have fast decay time of a few ns for positron emission tomography (PET). While the photoelectric absorption probability of the plastic for 511 keV gamma rays are extremely low due to its small density and effective atomic number, the cross section of Compton scattering is comparable to that of absorption by conventional inorganic scintillators. We thus propose TOF-PET using Compton scattering with plastic scintillators (Compton-PET), and performed fundamental experiments towards exploration of the Compton-PET capability. We demonstrated that the plastic scintillators achieved the better time resolution in comparison to LYSO(Ce) and GAGG(Ce) scintillators. In addition we evaluated the depth-of-interaction resolving capability with the plastic scintillators.

  10. Comparative Compton scattering studies in Cu2O and Ag2O

    International Nuclear Information System (INIS)

    Bandyopadhyay, S.; Chatterjee, A.K.; Saha, S.K.; Chatterjee, A.

    1994-01-01

    Compton scattering studies in polycrystalline Cu 2 O and Ag 2 O with 59.54 keV γ radiation are reported. A comparison has been made between the valance Compton profiles of these two components scaled to lattice momentum by normalizing them to equal electron density for outer valence electrons, and this comparison shows some differences between the bonding characters of Cu 2 O and Ag 2 O. (author)

  11. An energy-subtraction Compton scatter camera design for in vivo medical imaging of radiopharmaceuticals

    Science.gov (United States)

    Rohe, R. C.; Valentine, J. D.

    1996-12-01

    A Compton scatter camera (CSC) design is proposed for imaging radioisotopes used as biotracers. A clinical version may increase sensitivity by a factor of over 100, while maintaining or improving spatial resolution, as compared with existing Anger cameras that use lead collimators. This novel approach is based on using energy subtraction (/spl Delta/E=E/sub 0/-E/sub SC/, where E/sub 0/, /spl Delta/E, and E/sub SC/ are the energy at the emitted gamma ray, the energy deposited by the initial Compton scatter, and the energy of the Compton scattered photon) to determine the amount of energy deposited in the primary system. The energy subtraction approach allows the requirement of high energy resolution to be placed on a secondary detector system instead of the primary detector system. Requiring primary system high energy resolution has significantly limited previous CSC designs for medical imaging applications. Furthermore, this approach is dependent on optimizing the camera design for data acquisition of gamma rays that undergo only one Compton scatter in a low-Z primary detector system followed by total absorption of the Compton scattered photon in a high-Z secondary detector system. The proposed approach allows for a more compact primary detector system, a more simplified pulse processing interface, and a much less complicated detector cooling scheme as compared with previous CSC designs. Analytical calculations and Monte Carlo simulation results for some specific detector materials and geometries are presented.

  12. Electronic structure of lanthanum sesquioxide: A Compton scattering study

    Science.gov (United States)

    Sharma, Sonu; Sahariya, Jagrati; Arora, Gunjan; Ahuja, B. L.

    2014-10-01

    We present the first-ever experimental and theoretical momentum densities of La2O3. The Compton line shape is measured using a 20 Ci 137Cs Compton spectrometer at an intermediate resolution with full width at half maximum of 0.34 a.u. The experimental Compton profile is compared with the theoretical electron momentum densities computed using linear combination of atomic orbitals (LCAO) method with density functional theory (DFT). It is seen that the generalized gradient approximation (GGA) within DFT reconciles better with the experiment than other DFT based approximations, validating the GGA approximation for rare-earth sesquioxides. The energy bands and density of states computed using LCAO calculations show its wide band gap nature which is in tune with the available reflectivity and photo-absorption data. In addition, Mulliken's population and charge density are also computed and discussed.

  13. Electronic structure of lanthanum sesquioxide: A Compton scattering study

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Sonu [Department of Physics, M.L. Sukhadia University, Udaipur 313001, Rajasthan (India); Sahariya, Jagrati [Department of Physics, Manipal University Jaipur, Jaipur 303007, Rajasthan (India); Arora, Gunjan [Department of Physics, Geetanjali Institute of Technical Studies, Udaipur 313022, Rajasthan (India); Ahuja, B.L., E-mail: blahuja@yahoo.com [Department of Physics, M.L. Sukhadia University, Udaipur 313001, Rajasthan (India)

    2014-10-01

    We present the first-ever experimental and theoretical momentum densities of La{sub 2}O{sub 3}. The Compton line shape is measured using a 20 Ci {sup 137}Cs Compton spectrometer at an intermediate resolution with full width at half maximum of 0.34 a.u. The experimental Compton profile is compared with the theoretical electron momentum densities computed using linear combination of atomic orbitals (LCAO) method with density functional theory (DFT). It is seen that the generalized gradient approximation (GGA) within DFT reconciles better with the experiment than other DFT based approximations, validating the GGA approximation for rare-earth sesquioxides. The energy bands and density of states computed using LCAO calculations show its wide band gap nature which is in tune with the available reflectivity and photo-absorption data. In addition, Mulliken's population and charge density are also computed and discussed.

  14. The experimental challenge of virtual compton scattering above 8 GeV

    International Nuclear Information System (INIS)

    Pierre Bertin; Yves Roblin; Charles Hyde-Wright

    1999-01-01

    We discuss the experimental issues confronting measurements of the Virtual Compton Scattering (VCS) reaction ep->ep gamma with electron beam energies 6-30 GeV. We specifically address the kinematics of Deeply Virtual Compton Scattering (Deep Inelastic Scattering, with coincident detection of the exclusive real photon nearly parallel to the virtual photon direction) and large transverse momentum VCS (High energy VCS of arbitrary Q 2 , and the recoil proton emitted with high momentum transverse to the virtual photon direction). We discuss the experimental equipment necessary for these measurements. For the DVCS, we emphasize the importance of the Bethe-Heitler-Compton interference terms that can be measured with the electron-positron (beam charge) asymmetry, and the electron beam helicity asymmetry

  15. The experimental challenge of virtual compton scattering above 8 GeV

    CERN Document Server

    Bertin, P

    1999-01-01

    We discuss the experimental issues confronting measurements of the Virtual Compton Scattering (VCS) reaction ep->ep gamma with electron beam energies 6-30 GeV. We specifically address the kinematics of Deeply Virtual Compton Scattering (Deep Inelastic Scattering, with coincident detection of the exclusive real photon nearly parallel to the virtual photon direction) and large transverse momentum VCS (High energy VCS of arbitrary Q sup 2 , and the recoil proton emitted with high momentum transverse to the virtual photon direction). We discuss the experimental equipment necessary for these measurements. For the DVCS, we emphasize the importance of the Bethe-Heitler-Compton interference terms that can be measured with the electron-positron (beam charge) asymmetry, and the electron beam helicity asymmetry.

  16. A Programmable Liquid Collimator for Both Coded Aperture Adaptive Imaging and Multiplexed Compton Scatter Tomography

    Science.gov (United States)

    2012-03-01

    aperture system was first suggested by Dicke [21] and Ables [2] in 1968. X-ray astronomers had been seeking a system in which heavenly X-ray sources...uses Compton scatter X-rays [66]. including a fresco, and Egyptian mummy, and a medieval clasp [30]. It was found that Compton scatter imaging was useful...astron- omy”. Proceedings of the Astronomical Society of Australia, 1:172, December 1968. URL http://adsabs.harvard.edu/abs/1968PASAu...1..172A. [3

  17. Double electron ionization in Compton scattering of high energy photons by helium atoms

    International Nuclear Information System (INIS)

    Amusia, M.Y.; Mikhailov, A.I.

    1995-01-01

    The cross section for double-electron ionization of two-electron atoms and ions in Compton scattering of high energy photons is calculated. It is demonstrated that its dependence on the incoming photon frequency is the same as that for single-electron ionization. The ratio of open-quotes double-to-singleclose quotes ionization in Compton scattering was found to be energy independent and almost identical with the corresponding value for photoionization. For the He atom it is 1.68%. This surprising result deserves experimental verification

  18. Research building gamma Compton scattering measurement system and related exercises for training nuclear human resources

    International Nuclear Information System (INIS)

    Mai Xuan Phong; Nguyen Van Hung; Pham Xuan Hai; Le Van Ngoc; Nguyen Xuan Hai; Dang Lanh; Tran Quoc Duong

    2013-01-01

    In this subject we have designed and manufactured Compton scattering gamma measurement system based on the calculated optimal configuration as well as the conditions of protect radiation by using Monte-Carlo simulation program and fabrication with the optimal conditions were selected. Monte-Carlo simulation calculation of Compton scattering gamma follow different angles on copper, surveying gamma radiation attenuation characteristics of materials: lead, iron, aluminum, and compared with the experimental results performed on the same measurement system has been built and given for evaluation, comments. (author)

  19. Double electron ionization in Compton scattering of high energy photons by helium atoms

    Energy Technology Data Exchange (ETDEWEB)

    Amusia, M.Y.; Mikhailov, A.I. [St. Petersburg Nuclear Physics Institute, Gatchina (Russian Federation)

    1995-08-01

    The cross section for double-electron ionization of two-electron atoms and ions in Compton scattering of high energy photons is calculated. It is demonstrated that its dependence on the incoming photon frequency is the same as that for single-electron ionization. The ratio of {open_quotes}double-to-single{close_quotes} ionization in Compton scattering was found to be energy independent and almost identical with the corresponding value for photoionization. For the He atom it is 1.68%. This surprising result deserves experimental verification.

  20. Simulation of inverse Compton scattering and its implications on the scattered linewidth

    Science.gov (United States)

    Ranjan, N.; Terzić, B.; Krafft, G. A.; Petrillo, V.; Drebot, I.; Serafini, L.

    2018-03-01

    Rising interest in inverse Compton sources has increased the need for efficient models that properly quantify the behavior of scattered radiation given a set of interaction parameters. The current state-of-the-art simulations rely on Monte Carlo-based methods, which, while properly expressing scattering behavior in high-probability regions of the produced spectra, may not correctly simulate such behavior in low-probability regions (e.g. tails of spectra). Moreover, sampling may take an inordinate amount of time for the desired accuracy to be achieved. In this paper, we present an analytic derivation of the expression describing the scattered radiation linewidth and propose a model to describe the effects of horizontal and vertical emittance on the properties of the scattered radiation. We also present an improved version of the code initially reported in Krafft et al. [Phys. Rev. Accel. Beams 19, 121302 (2016), 10.1103/PhysRevAccelBeams.19.121302], that can perform the same simulations as those present in cain and give accurate results in low-probability regions by integrating over the emissions of the electrons. Finally, we use these codes to carry out simulations that closely verify the behavior predicted by the analytically derived scaling law.

  1. On the possibility of using X-ray Compton scattering to study magnetoelectrical properties of crystals

    Energy Technology Data Exchange (ETDEWEB)

    Collins, S. P., E-mail: steve.collins@diamond.ac.uk; Laundy, D.; Connolley, T.; Laan, G. van der; Fabrizi, F. [Diamond Light Source Ltd, Harwell Science and Innovation Campus, Didcot, OX11 0DE (United Kingdom); Janssen, O. [Department of Physics, New York University, New York, NY 10003 (United States); Cooper, M. J. [Department of Physics, University of Warwick, CV4 7AL (United Kingdom); Ebert, H.; Mankovsky, S. [Universität München, Department Chemie, Haus E2.033, Butenandtstrasse 5-13, D-81377 München (Germany)

    2016-02-16

    The possibility of using X-ray Compton scattering to reveal antisymmetric components of the electron momentum density, as a fingerprint of magnetoelectric sample properties, is investigated experimentally and theoretically by studying the polar ferromagnet GaFeO{sub 3}. This paper discusses the possibility of using Compton scattering – an inelastic X-ray scattering process that yields a projection of the electron momentum density – to probe magnetoelectrical properties. It is shown that an antisymmetric component of the momentum density is a unique fingerprint of such time- and parity-odd physics. It is argued that polar ferromagnets are ideal candidates to demonstrate this phenomenon and the first experimental results are shown, on a single-domain crystal of GaFeO{sub 3}. The measured antisymmetric Compton profile is very small (≃ 10{sup −5} of the symmetric part) and of the same order of magnitude as the statistical errors. Relativistic first-principles simulations of the antisymmetric Compton profile are presented and it is shown that, while the effect is indeed predicted by theory, and scales with the size of the valence spin–orbit interaction, its magnitude is significantly overestimated. The paper outlines some important constraints on the properties of the antisymmetric Compton profile arising from the underlying crystallographic symmetry of the sample.

  2. Electronic properties and Compton scattering studies of monoclinic tungsten dioxide

    Science.gov (United States)

    Heda, N. L.; Ahuja, Ushma

    2015-01-01

    We present the first ever Compton profile measurement of WO2 using a 20 Ci 137Cs γ-ray source. The experimental data have been used to test different approximations of density functional theory in linear combination of atomic orbitals (LCAO) scheme. It is found that theoretical Compton profile deduced using generalized gradient approximation (GGA) gives a better agreement than local density approximation and second order GGA. The computed energy bands, density of states and Mulliken's populations (MP) data confirm a metal-like behavior of WO2. The electronic properties calculated using LCAO approach are also compared with those obtained using full potential linearized augmented plane wave method. The nature of bonding in WO2 is also compared with isoelectronic WX2 (X=S, Se) compounds in terms of equal-valence-electron-density profiles and MP data, which suggest an increase in ionic character in the order WSe2→WS2→WO2.

  3. Foreign body detection in food materials using compton scattered x-rays

    Science.gov (United States)

    McFarlane, Nigel James Bruce

    This thesis investigated the application of X-ray Compton scattering to the problem of foreign body detection in food. The methods used were analytical modelling, simulation and experiment. A criterion was defined for detectability, and a model was developed for predicting the minimum time required for detection. The model was used to predict the smallest detectable cubes of air, glass, plastic and steel. Simulations and experiments were performed on voids and glass in polystyrene phantoms, water, coffee and muesli. Backscatter was used to detect bones in chicken meat. The effects of geometry and multiple scatter on contrast, signal-to-noise, and detection time were simulated. Compton scatter was compared with transmission, and the effect of inhomogeneity was modelled. Spectral shape was investigated as a means of foreign body detection. A signal-to-noise ratio of 7.4 was required for foreign body detection in food. A 0.46 cm cube of glass or a 1.19 cm cube of polystyrene were detectable in a 10 cm cube of water in one second. The minimum time to scan a whole sample varied as the 7th power of the foreign body size, and the 5th power of the sample size. Compton scatter inspection produced higher contrasts than transmission, but required longer measurement times because of the low number of photon counts. Compton scatter inspection of whole samples was very slow compared to production line speeds in the food industry. There was potential for Compton scatter in applications which did not require whole-sample scanning, such as surface inspection. There was also potential in the inspection of inhomogeneous samples. The multiple scatter fraction varied from 25% to 55% for 2 to 10 cm cubes of water, but did not have a large effect on the detection time. The spectral shape gave good contrasts and signal-to-noise ratios in the detection of chicken bones.

  4. Electronic properties and Compton scattering studies of monoclinic tungsten dioxide

    International Nuclear Information System (INIS)

    Heda, N.L.; Ahuja, Ushma

    2015-01-01

    We present the first ever Compton profile measurement of WO 2 using a 20 Ci 137 Cs γ-ray source. The experimental data have been used to test different approximations of density functional theory in linear combination of atomic orbitals (LCAO) scheme. It is found that theoretical Compton profile deduced using generalized gradient approximation (GGA) gives a better agreement than local density approximation and second order GGA. The computed energy bands, density of states and Mulliken's populations (MP) data confirm a metal-like behavior of WO 2 . The electronic properties calculated using LCAO approach are also compared with those obtained using full potential linearized augmented plane wave method. The nature of bonding in WO 2 is also compared with isoelectronic WX 2 (X=S, Se) compounds in terms of equal-valence-electron-density profiles and MP data, which suggest an increase in ionic character in the order WSe 2 →WS 2 →WO 2 . - Highlights: • Presented first-ever Compton profile (CP) measurements on WO 2 . • Analyzed CP data in terms of LCAO–DFT calculations. • Discussed energy band, DOS and Mulliken's population. • Discussed equally scaled CPs and bonding of isoelectronic WO 2 , WS 2 and WSe 2 . • Reported metallic character and Fermi surface topology of WO 2

  5. Virtual Compton Scattering off a Spinless Target in the AdS/QCD correspondence

    CERN Document Server

    Marquet, C.; Wallon, S.

    2010-01-01

    We perform a study of the doubly virtual Compton scattering off a spinless target gamma* P -> gamma* P' within the Anti-de Sitter(AdS)/QCD formalism. We find that the general structure allowed by the Lorentz invariance and gauge invariance of the Compton amplitude is not easily reproduced with the standard recipes of the AdS/QCD correspondence. In the soft-photon regime, where the semi-classical approximation is supposed to apply best, we show that the measurements of the electric and magnetic polarizabilities of a target like the charged pion in real Compton scattering, can already serve as stringent tests, and presumably exclude results based on the AdS/QCD correspondence in its minimal version.

  6. Design of a Polarised Positron Source Based on Laser Compton Scattering

    CERN Document Server

    Araki, S; Honda, Y; Kurihara, Y; Kuriki, M; Okugi, T; Omori, T; Taniguchi, T; Terunuma, N; Urakawa, J; Artru, X; Chevallier, M; Strakhovenko, V M; Bulyak, E; Gladkikh, P; Mönig, K; Chehab, R; Variola, A; Zomer, F; Guiducci, S; Raimondi, Pantaleo; Zimmermann, Frank; Sakaue, K; Hirose, T; Washio, M; Sasao, N; Yokoyama, H; Fukuda, M; Hirano, K; Takano, M; Takahashi, T; Sato, H; Tsunemi, A; Gao, J; Soskov, V

    2005-01-01

    We describe a scheme for producing polarised positrons at the ILC from polarised X-rays created by Compton scattering of a few-GeV electron beam off a CO2 or YAG laser. This scheme is very energy effective using high finesse laser cavities in conjunction with an electron storage ring.

  7. Designing scheme of a γ-ray ICT system using compton back-scattering

    International Nuclear Information System (INIS)

    Xiao Jianmin

    1998-01-01

    The designing scheme of a γ ray ICT system by using Compton back-scattering is put forward. The technical norms, detector system, γ radioactive source, mechanical scanning equipment, and data acquisition and image reconstruction principle of this ICT are described

  8. On the line-shape analysis of Compton profiles and its application to neutron scattering

    International Nuclear Information System (INIS)

    Romanelli, G.; Krzystyniak, M.

    2016-01-01

    Analytical properties of Compton profiles are used in order to simplify the analysis of neutron Compton scattering experiments. In particular, the possibility to fit the difference of Compton profiles is discussed as a way to greatly decrease the level of complexity of the data treatment, making the analysis easier, faster and more robust. In the context of the novel method proposed, two mathematical models describing the shapes of differenced Compton profiles are discussed: the simple Gaussian approximation for harmonic and isotropic local potential, and an analytical Gauss–Hermite expansion for an anharmonic or anisotropic potential. The method is applied to data collected by VESUVIO spectrometer at ISIS neutron and muon pulsed source (UK) on Copper and Aluminium samples at ambient and low temperatures. - Highlights: • A new method to analyse neutron Compton scattering data is presented. • The method allows many corrections on the experimental data to be avoided. • The number of needed fitting parameters is drastically reduced using the new method. • Mass-selective analysis is facilitated with parametric studies benefiting the most. • Observables linked to anisotropic momentum distribution are obtained analytically.

  9. Deeply-Virtual Compton Scattering on Deuterium and Neon at HERMES

    OpenAIRE

    Ellinghaus, F.; Shanidze, R.; Volmer, J.; collaboration, for the HERMES

    2002-01-01

    We report the first observation of azimuthal beam-spin asymmetries in hard electroproduction of real photons off nuclei. Attributed to the interference between the Bethe-Heitler process and the deeply-virtual Compton scattering process, the asymmetry gives access to the latter at the amplitude level. This process appears to be the theoretically cleanest way to access generalized parton distributions. The data presented here have been accumulated by the HERMES experiment at DESY, scattering th...

  10. Laser Pulse Shaping for Ultrahigh Intensity Compton Scattering*

    Science.gov (United States)

    Troha, A. L.; Le Sage, G. P.; Bennett, C.; Kolner, B. H.; Heritage, J. P.; Hartemann, F. V.; Luhmann, N. C., Jr.

    1996-11-01

    At ultrahigh intensities, where the normalized vector potential associated with the laser wave exceeds unity, the electron axial velocity modulation due to radiation pressure yields nonlinear Compton backscattered spectra. For applications requiring a narrow Doppler upshifted linewidth, such as the future g-g collider or focused X-ray generation, this poses a serious problem. It is shown that temporal laser pulse shaping using holographic (spectral) filtering at the Fourier plane of a chirped pulse laser amplifier, or similar approaches, can alleviate this problem, and that this technique can be scaled to the required multi-TW range. In particular, Compton backscattered spectra are calculated in the case of the optical square pulses similar to those experimentally observed by Weiner et al. Issues such as nonlinear effects, higher-order dispersion, 3D effects and optical noise are also discussed. *Work supported in part by DoD/AFOSR (MURI) F49620-95-1-0253, AFOSR (ATRI) F30602-94-2-001, ARO DAAHO4-95-1-0336 and LLNL/LDRD DoE W-7405-ENG-48

  11. Energy spectrum of Compton scattering of laser photons on relativistic electrons

    International Nuclear Information System (INIS)

    Ando, Hiroaki; Yoneda, Yasuharu

    1976-01-01

    The high energy photons in gamma-ray region are obtainable by the Compton scattering of laser photons on relativistic electrons. But the motion of the electrons in the storage ring is not necessarily uniform. In the study of the uneven effect, the energy distribution of scattered photons is derived from the assumed momentum distribution of incident electrons. It is generally impossible to derive the momentum distribution of incident electrons from the energy spectrum of scattered photons. The additional conditions which make this possible in a special case are considered. A calculational method is examined for deriving the energy spectrum of scattered photons from the assumed momentum distribution of incident electrons. (Mori, K.)

  12. A spectral geometric model for Compton single scatter in PET based on the single scatter simulation approximation

    Science.gov (United States)

    Kazantsev, I. G.; Olsen, U. L.; Poulsen, H. F.; Hansen, P. C.

    2018-02-01

    We investigate the idealized mathematical model of single scatter in PET for a detector system possessing excellent energy resolution. The model has the form of integral transforms estimating the distribution of photons undergoing a single Compton scattering with a certain angle. The total single scatter is interpreted as the volume integral over scatter points that constitute a rotation body with a football shape, while single scattering with a certain angle is evaluated as the surface integral over the boundary of the rotation body. The equations for total and sample single scatter calculations are derived using a single scatter simulation approximation. We show that the three-dimensional slice-by-slice filtered backprojection algorithm is applicable for scatter data inversion provided that the attenuation map is assumed to be constant. The results of the numerical experiments are presented.

  13. Study of electron densities of normal and neoplastic human breast tissues by Compton scattering using synchrotron radiation

    International Nuclear Information System (INIS)

    Antoniassi, M.; Conceição, A.L.C.; Poletti, M.E.

    2012-01-01

    Electron densities of 33 samples of normal (adipose and fibroglangular) and neoplastic (benign and malignant) human breast tissues were determined through Compton scattering data using a monochromatic synchrotron radiation source and an energy dispersive detector. The area of Compton peaks was used to determine the electron densities of the samples. Adipose tissue exhibits the lowest values of electron density whereas malignant tissue the highest. The relationship with their histology was discussed. Comparison with previous results showed differences smaller than 4%. - Highlights: ► Electron density of normal and neoplastic breast tissues was measured using Compton scattering. ► Monochromatic synchrotron radiation was used to obtain the Compton scattering data. ► The area of Compton peaks was used to determine the electron densities of samples. ► Adipose tissue shows the lowest electron density values whereas the malignant tissue the highest. ► Comparison with previous results showed differences smaller than 4%.

  14. Development of double-scattering compton camera for gamma-ray emission imaging

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hee

    2012-02-15

    The Compton camera with its unique Compton kinematics-based electronic collimation method has attracted great interest as the most promising candidate for a future gamma-ray emission imaging device due to its various advantages over conventional imaging devices. In this thesis, the proper structure and detector configuration for high-energy gamma-ray emission imaging were determined. In addition, the imaging performance of the Compton camera was experimentally evaluated after constructing a proof-of-principle imaging system. The two, single- and double-scattering Compton cameras were modeled using the Geant4 Monte Carlo simulation toolkit, and their imaging sensitivities were calculated as a function of source energy. Above a certain source energy (> a few hundred keV, depending on the detector configuration), the double-scattering type showed higher imaging sensitivity than the single-scattering type, which difference widened with increasing source energy. As such, the double-scattering Compton camera was determined to be more suitable for high-energy gamma-ray emission imaging. The Si/Si/NaI(Tl) detector configuration was chosen, owing to the fact that it does not require a cooling system: this allowed for construction of a very compact imaging system. The performances of the double-scattering Compton camera's component detectors (two double-sided silicon strip detectors [DSSDs] as the scatter detectors; a NaI(Tl) scintillation detector as the absorber detector) were evaluated in terms of energy and timing resolution. According to these results, Geant4 Monte Carlo simulations were performed to determine the optimal geometrical configuration of the component detectors and to quantitatively evaluate the effect of the detector parameters on angular resolution. Also, a Compton-edge based energy-calibration method was developed and applied to the DSSDs. As a result, the energy calibration errors were significantly reduced, from 15.5% (356 keV peak of {sup 133}Ba

  15. The integration of improved Monte Carlo compton scattering algorithms into the Integrated TIGER Series

    International Nuclear Information System (INIS)

    Quirk, Thomas J. IV

    2004-01-01

    The Integrated TIGER Series (ITS) is a software package that solves coupled electron-photon transport problems. ITS performs analog photon tracking for energies between 1 keV and 1 GeV. Unlike its deterministic counterpart, the Monte Carlo calculations of ITS do not require a memory-intensive meshing of phase space; however, its solutions carry statistical variations. Reducing these variations is heavily dependent on runtime. Monte Carlo simulations must therefore be both physically accurate and computationally efficient. Compton scattering is the dominant photon interaction above 100 keV and below 5-10 MeV, with higher cutoffs occurring in lighter atoms. In its current model of Compton scattering, ITS corrects the differential Klein-Nishina cross sections (which assumes a stationary, free electron) with the incoherent scattering function, a function dependent on both the momentum transfer and the atomic number of the scattering medium. While this technique accounts for binding effects on the scattering angle, it excludes the Doppler broadening the Compton line undergoes because of the momentum distribution in each bound state. To correct for these effects, Ribbefor's relativistic impulse approximation (IA) will be employed to create scattering cross section differential in both energy and angle for each element. Using the parameterizations suggested by Brusa et al., scattered photon energies and angle can be accurately sampled at a high efficiency with minimal physical data. Two-body kinematics then dictates the electron's scattered direction and energy. Finally, the atomic ionization is relaxed via Auger emission or fluorescence. Future work will extend these improvements in incoherent scattering to compounds and to adjoint calculations.

  16. Development of compton scatter X-ray technique for bone density measurement in vivo

    International Nuclear Information System (INIS)

    Kapoor, K.K.; Clarke, R.L.; Barton, R.D.

    1980-01-01

    A technique for bone density measurement in vivo based on the fact that cross-section for compton scattering depends directly upon the electron density of the scattering material has been developed and described. The theory is explained. Electron density is converted to mass density by using weighted average of atomic number to mass number of the material. The method uses a low energy X-ray source and three scintillation detectors. The method has the advantage of permitting measurement of bones in vivo of different sizes and shapes without recalibration and without any specific knowledge of absorption of scattering properties of the surrounding tissue. (M.G.B.)

  17. Compton scattering study of electron momentum distribution in lithium fluoride using 662 keV gamma radiations

    International Nuclear Information System (INIS)

    Vijayakumar, R.; Shivaramu; Ramamurthy, N.; Ford, M.J.

    2008-01-01

    Here we report the first ever 137 Cs Compton spectroscopy study of lithium fluoride. The spherical average Compton profiles of lithium fluoride are deduced from Compton scattering measurements on poly crystalline sample at gamma ray energy of 662 keV. To compare the experimental data, we have computed the spherical average Compton profiles using self-consistent Hartree-Fock wave functions employed on linear combination of atomic orbital (HF-LCAO) approximation. The directional Compton profiles and their anisotropic effects are also calculated using the same HF-LCAO approximation. The experimental spherical average profiles are found to be in good agreement with the corresponding HF-LCAO calculations and in qualitative agreement with Hartree-Fock free atom values. The present experimental isotropic and calculated directional profiles are also compared with the available experimental isotropic and directional Compton profiles using 59.54 and 159 keV γ-rays

  18. Describing Compton scattering and two-quanta positron annihilation based on Compton profiles: Two models suited for the Monte Carlo method

    CERN Document Server

    Bohlen, TT; Patera, V; Sala, P R

    2012-01-01

    An accurate description of the basic physics processes of Compton scattering and positron annihilation in matter requires the consideration of atomic shell structure effects and, in specific, the momentum distributions of the atomic electrons. Two algorithms which model Compton scattering and two-quanta positron annihilation at rest accounting for shell structure effects are proposed. Two-quanta positron annihilation is a physics process which is of particular importance for applications such as positron emission tomography (PET). Both models use a detailed description of the processes which incorporate consistently Doppler broadening and binding effects. This together with the relatively low level of complexity of the models makes them particularly suited to be employed by fast sampling methods for Monte Carlo particle transport. Momentum distributions of shell electrons are obtained from parametrized one-electron Compton profiles. For conduction electrons, momentum distributions are derived in the framework...

  19. A measurement method of a detector response function for monochromatic electrons based on the Compton scattering

    International Nuclear Information System (INIS)

    Bakhlanov, S.V.; Bazlov, N.V.; Derbin, A.V.; Drachnev, I.S.; Kayunov, A.S.; Muratova, V.N.; Semenov, D.A.; Unzhakov, E.V.

    2016-01-01

    In this paper we present a method of scintillation detector energy calibration using the gamma-rays. The technique is based on the Compton scattering of gamma-rays in a scintillation detector and subsequent photoelectric absorption of the scattered photon in the Ge-detector. The novelty of this method is that the source of gamma rays, the germanium and scintillation detectors are immediately arranged adjacent to each other. The method presents an effective solution for the detectors consisting of a low atomic number materials, when the ratio between Compton effect and photoelectric absorption is large and the mean path of gamma-rays is comparable to the size of the detector. The technique can be used for the precision measurements of the scintillator light yield dependence on the electron energy.

  20. Compton scatter correction in case of multiple crosstalks in SPECT imaging.

    Science.gov (United States)

    Sychra, J J; Blend, M J; Jobe, T H

    1996-02-01

    A strategy for Compton scatter correction in brain SPECT images was proposed recently. It assumes that two radioisotopes are used and that a significant portion of photons of one radioisotope (for example, Tc99m) spills over into the low energy acquisition window of the other radioisotope (for example, Tl201). We are extending this approach to cases of several radioisotopes with mutual, multiple and significant photon spillover. In the example above, one may correct not only the Tl201 image but also the Tc99m image corrupted by the Compton scatter originating from the small component of high energy Tl201 photons. The proposed extension is applicable to other anatomical domains (cardiac imaging).

  1. Image combination enhancement method for X-ray compton back-scattering security inspection body scanner

    International Nuclear Information System (INIS)

    Wang Huaiying; Zhang Yujin; Yang Lirui; Li Dong

    2011-01-01

    As for X-ray Compton Back-Scattering (CBS) body scanner, image clearness is very important for the performance of detecting the contraband hidden on the body. A new image combination enhancement method is provided based on characteristics of CBS body images and points of human vision. After processed by this method, the CBS image will be obviously improved with clear levels, distinct outline and uniform background. (authors)

  2. Representation of the virtual Compton amplitude for polarized scattering in the generalized Bjorken region

    OpenAIRE

    Blümlein, J.; Gezer, B.; Robaschik, D.

    1999-01-01

    The Compton amplitude is calculated in terms of expectation values of light-ray quark operators. As a technical tool we apply the nonlocal light-cone expansion. Thereby we express the expectation value of the vector light-ray operator with the help of the expectation value of the corresponding scalar operator of twist 2. This allows important simplifications. In the limit of forward scattering the integral relations between the twist-2 contributions of the structure functions are implied dire...

  3. Photon polarization in Compton scattering: pulse shape effects

    International Nuclear Information System (INIS)

    Boca, M; Stoica, C; Dumitriu, A; Florescu, V

    2015-01-01

    We study in the framework of quantum electrodynamics the scattering of a plane wave electromagnetic field on free electrons in the low intensity limit. We derive analytic formulas describing the polarization properties of the emitted photons. We discuss and illustrate with a numerical example the effects of the electromagnetic pulse duration on their polarization

  4. Deeply Virtual Compton Scattering off a deuterium target at the HERMES experiment

    International Nuclear Information System (INIS)

    Movsisyan, Aram

    2011-05-01

    Deeply virtual Compton scattering is studied in this report, using all data collected at the HERMES experiment from 1996 to 2005. Azimuthal asymmetries with respect to beam-helicity, beam-charge and target polarization alone and also to their different combinations for hard exclusive electroproduction of real photons in deep-inelastic scattering from a both unpolarized and longitudinally polarized deuterium targets are measured. The asymmetries are attributed to the interference between the deeply virtual Compton scattering and Bethe-Heitler processes. The asymmetries are observed in the exclusive region -(1.5) 2 GeV 2 2 X 2 GeV 2 of the squared missing mass. The dependences of these asymmetries on -t, x N , or Q 2 are investigated. The results include the coherent process ed→edγ and the incoherent process ed→epnγ where in addition a nucleon may be excited to a resonance. For an unpolarized deuterium target, the leading Fourier amplitude of the beam-helicity asymmetry that is sensitive to the interference term is found to be substantial, but no significant t dependence is observed. The leading amplitude of the beam-charge asymmetry is substantial at large -t, but becomes small at small values of -t. The amplitudes of the beam-helicity asymmetry that are sensitive to the squared DVCS term are found to be consistent with zero. The deuteron Compton form factor H 1 appears to have a similar behavior as H of the proton. (orig.)

  5. Performance studies towards a TOF-PET sensor using Compton scattering at plastic scintillators

    Science.gov (United States)

    Kuramoto, M.; Nakamori, T.; Gunji, S.; Kamada, K.; Shoji, Y.; Yoshikawa, A.; Aoki, T.

    2018-01-01

    We have developed a sensor head for a time-of-flight (TOF) PET scanner using plastic scintillators that have a very fast timing property. Given the very small cross section of photoelectric absorption in plastic scintillators at 511 keV, we use Compton scattering in order to compensate for detection efficiency. The detector will consist of two layers of scatterers and absorbers which are made of plastic and inorganic scintillators such as GAGG:Ce, respectively. Signals are read by monolithic Multi Pixel Photon Counters, and with energy deposits and interaction time stamps are being acquired. The scintillators are built to be capable of resolving interaction position in three dimensions, so that our system has also a function of depth-of-interaction (DOI) PET scanners. TOF resolution of ~ 200 ps (FWHM) is achieved in both cases of using the leading-edge discriminator and time-walk correction and using a configuration sensitive to DOI. Both the position resolution and spectroscopy are demonstrated using the prototype data acquisition system, with Compton scattering events subsequently being obtained. We also demonstrated that the background rejection technique using the Compton cone constraint could be valid with our system.

  6. Compton scattering spectrum as a source of information of normal and neoplastic breast tissues' composition

    International Nuclear Information System (INIS)

    Antoniassi, M.; Conceição, A.L.C.; Poletti, M.E.

    2012-01-01

    In this work we measured X-ray scatter spectra from normal and neoplastic breast tissues using photon energy of 17.44 keV and a scattering angle of 90°, in order to study the shape (FWHM) of the Compton peaks. The obtained results for FWHM were discussed in terms of composition and histological characteristics of each tissue type. The statistical analysis shows that the distribution of FWHM of normal adipose breast tissue clearly differs from all other investigated tissues. Comparison between experimental values of FWHM and effective atomic number revealed a strong correlation between them, showing that the FWHM values can be used to provide information about elemental composition of the tissues. - Highlights: ► X-ray scatter spectra from normal and neoplastic breast tissues were measured. ► Shape (FWHM) of Compton peak was related with elemental composition and characteristics of each tissue type. ► A statistical hypothesis test showed clear differences between normal and neoplastic breast tissues. ► There is a strong correlation between experimental values of FWHM and effective atomic number. ► Shape (FWHM) of Compton peak can be used to provide information about elemental composition of the tissues.

  7. A didactic experiment showing the Compton scattering by means of a clinical gamma camera.

    Science.gov (United States)

    Amato, Ernesto; Auditore, Lucrezia; Campennì, Alfredo; Minutoli, Fabio; Cucinotta, Mariapaola; Sindoni, Alessandro; Baldari, Sergio

    2017-06-01

    We describe a didactic approach aimed to explain the effect of Compton scattering in nuclear medicine imaging, exploiting the comparison of a didactic experiment with a gamma camera with the outcomes from a Monte Carlo simulation of the same experimental apparatus. We employed a 99m Tc source emitting 140.5keV photons, collimated in the upper direction through two pinholes, shielded by 6mm of lead. An aluminium cylinder was placed on the source at 50mm of distance. The energy of the scattered photons was measured on the spectra acquired by the gamma camera. We observed that the gamma ray energy measured at each step of rotation gradually decreased from the characteristic energy of 140.5keV at 0° to 102.5keV at 120°. A comparison between the obtained data and the expected results from the Compton formula and from the Monte Carlo simulation revealed a full agreement within the experimental error (relative errors between -0.56% and 1.19%), given by the energy resolution of the gamma camera. Also the electron rest mass has been evaluated satisfactorily. The experiment was found useful in explaining nuclear medicine residents the phenomenology of the Compton scattering and its importance in the nuclear medicine imaging, and it can be profitably proposed during the training of medical physics residents as well. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. Rayleigh to Compton ratio scatter tomography applied to breast cancer diagnosis: A preliminary computational study

    International Nuclear Information System (INIS)

    Antoniassi, M.; Conceição, A.L.C.; Poletti, M.E.

    2014-01-01

    In the present work, a tomographic technique based on Rayleigh to Compton scattering ratio (R/C) was studied using computational simulation in order to assess its application to breast cancer diagnosis. In this preliminary study, some parameters that affect the image quality were evaluated, such as: (i) energy beam, (ii) size and glandularity of the breast, and (iii) statistical count noise. The results showed that the R/C contrast increases with increasing photon energy and decreases with increasing glandularity of the sample. The statistical noise showed to be a significant parameter, although the quality of the obtained images was acceptable for a considerable range of noise level. The preliminary results suggest that the R/C tomographic technique has a potential of being applied as a complementary tool in the breast cancer diagnostic. - Highlights: ► A tomographic technique based on Rayleigh to Compton scattering ratio is proposed in order to study breast tissues. ► The Rayleigh to Compton scattering ratio technique is compared with conventional transmission technique. ► The influence of experimental parameters (energy, sample, detection system) is studied

  9. Measurement of deeply virtual Compton scattering at HERA

    Czech Academy of Sciences Publication Activity Database

    Aktas, A.; Andreev, V.; Anthonis, T.; Cvach, Jaroslav; Reimer, Petr; Sedlák, Kamil; Zálešák, Jaroslav

    2005-01-01

    Roč. 44, - (2005), s. 1-11 ISSN 1434-6044 R&D Projects: GA MŠk(CZ) LA 116; GA MŠk(CZ) LN00A006 Institutional research plan: CEZ:AV0Z10100502 Keywords : HI experiment * ep scattering * cross section Subject RIV: BF - Elementary Particles and High Energy Physics Impact factor: 3.209, year: 2005

  10. Analytical description of photon beam phase spaces in inverse Compton scattering sources

    Directory of Open Access Journals (Sweden)

    C. Curatolo

    2017-08-01

    Full Text Available We revisit the description of inverse Compton scattering sources and the photon beams generated therein, emphasizing the behavior of their phase space density distributions and how they depend upon those of the two colliding beams of electrons and photons. The main objective is to provide practical formulas for bandwidth, spectral density, brilliance, which are valid in general for any value of the recoil factor, i.e. both in the Thomson regime of negligible electron recoil, and in the deep Compton recoil dominated region, which is of interest for gamma-gamma colliders and Compton sources for the production of multi-GeV photon beams. We adopt a description based on the center of mass reference system of the electron-photon collision, in order to underline the role of the electron recoil and how it controls the relativistic Doppler/boost effect in various regimes. Using the center of mass reference frame greatly simplifies the treatment, allowing us to derive simple formulas expressed in terms of rms momenta of the two colliding beams (emittance, energy spread, etc. and the collimation angle in the laboratory system. Comparisons with Monte Carlo simulations of inverse Compton scattering in various scenarios are presented, showing very good agreement with the analytical formulas: in particular we find that the bandwidth dependence on the electron beam emittance, of paramount importance in Thomson regime, as it limits the amount of focusing imparted to the electron beam, becomes much less sensitive in deep Compton regime, allowing a stronger focusing of the electron beam to enhance luminosity without loss of mono-chromaticity. A similar effect occurs concerning the bandwidth dependence on the frequency spread of the incident photons: in deep recoil regime the bandwidth comes out to be much less dependent on the frequency spread. The set of formulas here derived are very helpful in designing inverse Compton sources in diverse regimes, giving a

  11. The use of Compton scattering in detecting anomaly in soil-possible use in pyromaterial detection

    Science.gov (United States)

    Abedin, Ahmad Firdaus Zainal; Ibrahim, Noorddin; Zabidi, Noriza Ahmad; Demon, Siti Zulaikha Ngah

    2016-01-01

    The Compton scattering is able to determine the signature of land mine detection based on dependency of density anomaly and energy change of scattered photons. In this study, 4.43 MeV gamma of the Am-Be source was used to perform Compton scattering. Two detectors were placed between source with distance of 8 cm and radius of 1.9 cm. Detectors of thallium-doped sodium iodide NaI(TI) was used for detecting gamma ray. There are 9 anomalies used in this simulation. The physical of anomaly is in cylinder form with radius of 10 cm and 8.9 cm height. The anomaly is buried 5 cm deep in the bed soil measured 80 cm radius and 53.5 cm height. Monte Carlo methods indicated the scattering of photons is directly proportional to density of anomalies. The difference between detector response with anomaly and without anomaly namely contrast ratio values are in a linear relationship with density of anomalies. Anomalies of air, wood and water give positive contrast ratio values whereas explosive, sand, concrete, graphite, limestone and polyethylene give negative contrast ratio values. Overall, the contrast ratio values are greater than 2 % for all anomalies. The strong contrast ratios result a good detection capability and distinction between anomalies.

  12. Deeply Virtual Compton Scattering off a deuterium target at the HERMES experiment

    Energy Technology Data Exchange (ETDEWEB)

    Movsisyan, Aram

    2011-05-15

    Deeply virtual Compton scattering is studied in this report, using all data collected at the HERMES experiment from 1996 to 2005. Azimuthal asymmetries with respect to beam-helicity, beam-charge and target polarization alone and also to their different combinations for hard exclusive electroproduction of real photons in deep-inelastic scattering from a both unpolarized and longitudinally polarized deuterium targets are measured. The asymmetries are attributed to the interference between the deeply virtual Compton scattering and Bethe-Heitler processes. The asymmetries are observed in the exclusive region -(1.5){sup 2} GeV{sup 2}Compton form factor H{sub 1} appears to have a similar behavior as H of the proton. (orig.)

  13. Characterization of Compton-scatter imaging with an analytical simulation method

    Science.gov (United States)

    Jones, Kevin C.; Redler, Gage; Templeton, Alistair; Bernard, Damian; Turian, Julius V.; Chu, James C. H.

    2018-01-01

    By collimating the photons scattered when a megavoltage therapy beam interacts with the patient, a Compton-scatter image may be formed without the delivery of an extra dose. To characterize and assess the potential of the technique, an analytical model for simulating scatter images was developed and validated against Monte Carlo (MC). For three phantoms, the scatter images collected during irradiation with a 6 MV flattening-filter-free therapy beam were simulated. Images, profiles, and spectra were compared for different phantoms and different irradiation angles. The proposed analytical method simulates accurate scatter images up to 1000 times faster than MC. Minor differences between MC and analytical simulated images are attributed to limitations in the isotropic superposition/convolution algorithm used to analytically model multiple-order scattering. For a detector placed at 90° relative to the treatment beam, the simulated scattered photon energy spectrum peaks at 140-220 keV, and 40-50% of the photons are the result of multiple scattering. The high energy photons originate at the beam entrance. Increasing the angle between source and detector increases the average energy of the collected photons and decreases the relative contribution of multiple scattered photons. Multiple scattered photons cause blurring in the image. For an ideal 5 mm diameter pinhole collimator placed 18.5 cm from the isocenter, 10 cGy of deposited dose (2 Hz imaging rate for 1200 MU min-1 treatment delivery) is expected to generate an average 1000 photons per mm2 at the detector. For the considered lung tumor CT phantom, the contrast is high enough to clearly identify the lung tumor in the scatter image. Increasing the treatment beam size perpendicular to the detector plane decreases the contrast, although the scatter subject contrast is expected to be greater than the megavoltage transmission image contrast. With the analytical method, real-time tumor tracking may be possible

  14. Measurement of deeply virtual Compton scattering using the ZEUS detector at HERA

    International Nuclear Information System (INIS)

    Grabowska-Bold, I.

    2004-08-01

    The cross sections for deeply virtual compton scattering in the reaction ep → e'γp' has been measured with the ZEUS detector at HERA using integrated luminosities of 95 pb -1 of e + p and 17 pb -1 of e - p collisions. Cross sections are presented as a function of the exchanged photon virtuality, Q 2 , and the centre-of-mass energy, W, of the γ * p system in the region 5 2 2 and 40 < W < 140 GeV. The obtained results are compared to QCD-based calculations. (orig.)

  15. Source of X-ray radiation based on back compton scattering

    CERN Document Server

    Bulyak, E V; Karnaukhov, I M; Kononenko, S G; Lapshin, V G; Mytsykov, A O; Telegin, Yu P; Shcherbakov, A A; Zelinsky, Andrey Yurij

    2000-01-01

    Applicability was studied and previous estimation was done of power X-ray beams generation by backward Compton scattering of a laser photon beam on a cooled down electron beam. The few MeV electron beam circulating in a compact storage ring can be cooled down by interaction of that beam with powerful laser radiation of micrometer wavelength to achieve normalized emittance of 10 sup - sup 7 m. A tunable X-ray source of photons of energy ranging from few keV up to a hundred keV could result from the interaction of the laser beam with a dense electron beam.

  16. Source of X-ray radiation based on back compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Bulyak, E.V.; Gladkikh, P.I.; Karnaukhov, I.M.; Kononenko, S.G.; Lapshin, V.I.; Mytsykov, A.O.; Telegin, Yu.N.; Shcherbakov, A.A. E-mail: shcherbakov@kipt.kharkov.ua; Zelinsky, A.Yu

    2000-06-21

    Applicability was studied and previous estimation was done of power X-ray beams generation by backward Compton scattering of a laser photon beam on a cooled down electron beam. The few MeV electron beam circulating in a compact storage ring can be cooled down by interaction of that beam with powerful laser radiation of micrometer wavelength to achieve normalized emittance of 10{sup -7} m. A tunable X-ray source of photons of energy ranging from few keV up to a hundred keV could result from the interaction of the laser beam with a dense electron beam.

  17. Source of X-ray radiation based on back compton scattering

    International Nuclear Information System (INIS)

    Bulyak, E.V.; Gladkikh, P.I.; Karnaukhov, I.M.; Kononenko, S.G.; Lapshin, V.I.; Mytsykov, A.O.; Telegin, Yu.N.; Shcherbakov, A.A.; Zelinsky, A.Yu.

    2000-01-01

    Applicability was studied and previous estimation was done of power X-ray beams generation by backward Compton scattering of a laser photon beam on a cooled down electron beam. The few MeV electron beam circulating in a compact storage ring can be cooled down by interaction of that beam with powerful laser radiation of micrometer wavelength to achieve normalized emittance of 10 -7 m. A tunable X-ray source of photons of energy ranging from few keV up to a hundred keV could result from the interaction of the laser beam with a dense electron beam

  18. Compton Scattering Cross Section on the Proton at High Momentum Transfer

    International Nuclear Information System (INIS)

    A. Danagoulian; V.H. Mamyan; M. Roedelbronn; K.A. Aniol; J.R.M. Annand; P.Y. Bertin; L. Bimbot; P. Bosted; J.R. Calarco; A. Camsonne; C.C. Chang; T.-H. Chang; J.-P. Chen; Seonho Choi; E. Chudakov; P. Degtyarenko; C.W. de Jager; A. Deur; D. Dutta; K. Egiyan; H. Gao; F. Garibaldi; O. Gayou; R. Gilman; A. Glamazdin; C. Glashausser; J. Gomez; D.J. Hamilton; J.-O. Hansen; D. Hayes; D.W. Higinbotham; W. Hinton; T. Horn; C. Howell; T. Hunyady; C.E. Hyde-Wright; X. Jiang; M.K. Jones; M. Khandaker; A. Ketikyan; V. Koubarovski; K. Kramer; G. Kumbartzki; G. Laveissiere; J. LeRose; R.A. Lindgren; D.J. Margaziotis; P. Markowitz; K. McCormick; Z.-E. Meziani; R. Michaels; P. Moussiegt; S. Nanda; A.M. Nathan; D.M. Nikolenko; V. Nelyubin; B.E. Norum; K. Paschke; L. Pentchev; C.F. Perdrisat; E. Piasetzky; R. Pomatsalyuk; V.A. Punjabi; I. Rachek; A. Radyushkin; B. Reitz; R. Roche; G. Ron; F. Sabatie; A. Saha; N. Savvinov; A. Shahinyan; Y. Shestakov; S. Sirca; K. Slifer; P. Solvignon; P. Stoler; S. Tajima; V. Sulkosky; L. Todor; B. Vlahovic; L.B. Weinstein; K. Wang; B. Wojtsekhowski; H. Voskanyan; H. Xiang; X. Zheng; L. Zhu

    2007-01-01

    Cross-section values for Compton scattering on the proton were measured at 25 kinematic settings over the range s = 5-11 and -t = 2-7 GeV2 with statistical accuracy of a few percent. The scaling power for the s-dependence of the cross section at fixed center of mass angle was found to be 8.0 +/- 0.2, strongly inconsistent with the prediction of perturbative QCD. The observed cross section values are in fair agreement with the calculations using the handbag mechanism, in which the external photons couple to a single quark

  19. Local Two-Photon Couplings and the J=0 Fixed Pole in Real and Virtual Compton Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Brodsky, Stanley J.; Llanes-Estrada, Felipe J.; Szczepaniak, Adam P.

    2008-12-05

    The local coupling of two photons to the fundamental quark currents of a hadron gives an energy-independent contribution to the Compton amplitude proportional to the charge squared of the struck quark, a contribution which has no analog in hadron scattering reactions. We show that this local contribution has a real phase and is universal, giving the same contribution for real or virtual Compton scattering for any photon virtuality and skewness at fixed momentum transfer squared t. The t-dependence of this J = 0 fixed Regge pole is parameterized by a yet unmeasured even charge-conjugation form factor of the target nucleon. The t = 0 limit gives an important constraint on the dependence of the nucleon mass on the quark mass through the Weisberger relation. We discuss how this 1=x form factor can be extracted from high energy deeply virtual Compton scattering and examine predictions given by models of the H generalized parton distribution.

  20. The use of Compton scattering to differentiate between classifications of normal and diseased breast tissue

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, Elaine A; Farquharson, Michael J; Flinton, David M [School of Allied Health Sciences, City University, Charterhouse Square, London EC1M 6PA (United Kingdom)

    2005-07-21

    This study describes a technique for measuring the electron density of breast tissue utilizing Compton scattered photons. The K{sub {alpha}}{sub 2} line from a tungsten target industrial x-ray tube (57.97 keV) was used and the scattered x-rays collected at an angle of 30{sup 0}. At this angle the Compton and coherent photon peaks can be resolved using an energy dispersive detector and a peak fitting algorithm. The system was calibrated using solutions of known electron density. The results obtained from a pilot study of 22 tissues are presented. The tissue samples investigated comprise four different tissue classifications: adipose, malignancy, fibroadenoma and fibrocystic change (FCC). It is shown that there is a difference between adipose and malignant tissue, to a value of 9.0%, and between adipose and FCC, to a value of 12.7%. These figures are found to be significant by statistical analysis. The differences between adipose and fibroadenoma tissues (2.2%) and between malignancy and FCC (3.4%) are not significant. It is hypothesized that the alteration in glucose uptake within malignant cells may cause these tissues to have an elevated electron density. The fibrotic nature of tissue that has undergone FCC gives the highest measure of all tissue types.

  1. Measurements of double-polarized compton scattering asymmetries and extraction of the proton spin polarizabilities.

    Science.gov (United States)

    Martel, P P; Miskimen, R; Aguar-Bartolome, P; Ahrens, J; Akondi, C S; Annand, J R M; Arends, H J; Barnes, W; Beck, R; Bernstein, A; Borisov, N; Braghieri, A; Briscoe, W J; Cherepnya, S; Collicott, C; Costanza, S; Denig, A; Dieterle, M; Downie, E J; Fil'kov, L V; Garni, S; Glazier, D I; Gradl, W; Gurevich, G; Hall Barrientos, P; Hamilton, D; Hornidge, D; Howdle, D; Huber, G M; Jude, T C; Kaeser, A; Kashevarov, V L; Keshelashvili, I; Kondratiev, R; Korolija, M; Krusche, B; Lazarev, A; Lisin, V; Livingston, K; MacGregor, I J D; Mancell, J; Manley, D M; Meyer, W; Middleton, D G; Mushkarenkov, A; Nefkens, B M K; Neganov, A; Nikolaev, A; Oberle, M; Ortega Spina, H; Ostrick, M; Ott, P; Otte, P B; Oussena, B; Pedroni, P; Polonski, A; Polyansky, V; Prakhov, S; Rajabi, A; Reicherz, G; Rostomyan, T; Sarty, A; Schrauf, S; Schumann, S; Sikora, M H; Starostin, A; Steffen, O; Strakovsky, I I; Strub, T; Supek, I; Thiel, M; Tiator, L; Thomas, A; Unverzagt, M; Usov, Y; Watts, D P; Witthauer, L; Werthmüller, D; Wolfes, M

    2015-03-20

    The spin polarizabilities of the nucleon describe how the spin of the nucleon responds to an incident polarized photon. The most model-independent way to extract the nucleon spin polarizabilities is through polarized Compton scattering. Double-polarized Compton scattering asymmetries on the proton were measured in the Δ(1232) region using circularly polarized incident photons and a transversely polarized proton target at the Mainz Microtron. Fits to asymmetry data were performed using a dispersion model calculation and a baryon chiral perturbation theory calculation, and a separation of all four proton spin polarizabilities in the multipole basis was achieved. The analysis based on a dispersion model calculation yields γ(E1E1)=-3.5±1.2, γ(M1M1)=3.16±0.85, γ(E1M2)=-0.7±1.2, and γ(M1E2)=1.99±0.29, in units of 10(-4)  fm(4).

  2. Measurement of Compton scattering cross section during PrimEx-II Experiment at Jefferson Lab

    Science.gov (United States)

    Ye, Li; PrimEx Collaboration

    2017-09-01

    The electron Compton scattering is the most known fundamental QED process, however, a precision measurement of its cross section for the beam energy above 1 GeV has been lacking up to now. An updated high precision measurement of the neutral pion lifetime via the Primakoff effect (PrimEx-II) experiment was performed in Hall B of Jefferson Lab in 2010. The experiment used small angle coherent photoproduction of π0's in the Coulomb field of a nucleus, i.e. the Primakoff effect, to determine the lifetime with a precision of less than 1.5 % . It therefore requires thorough understanding of the underlying systematic uncertainties. To facilitate that data for well known electromagnetic processes were taken concurrently with the photoproduction data. This analysis pertains to measuring the Compton scattering cross section, which occurs at similar kinematics as the primary process. The combination of the well established theory of this process with large collected statistics allowed to extract this cross section with high precision in an energy region of 4-5 GeV for 12C and 28Si targets. The results of this analysis will be presented. This work is supported in part by the U.S. Department of Energy under Contacts No. DE-FG02-03ER41528, NSF MRI PHY-0079840, Thomas Jefferson National Laboratory, Mississippi State University and PrimEx collaboration.

  3. Constant-q data representation in Neutron Compton scattering on the VESUVIO spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Senesi, R. [Dipartimento di Fisica, Universita degli Studi di Roma ' Tor Vergata' , Via della Ricerca Scientifica 1, 00133 Roma (Italy); Centro NAST, Nanoscienze and Nanotecnologie and Strumentazione, Universita degli Studi di Roma ' Tor Vergata' , Via della Ricerca Scientifica 1, 00133 Roma (Italy)], E-mail: roberto.senesi@roma2.infn.it; Pietropaolo, A.; Andreani, C. [Dipartimento di Fisica, Universita degli Studi di Roma ' Tor Vergata' , Via della Ricerca Scientifica 1, 00133 Roma (Italy); Centro NAST, Nanoscienze and Nanotecnologie and Strumentazione, Universita degli Studi di Roma ' Tor Vergata' , Via della Ricerca Scientifica 1, 00133 Roma (Italy)

    2008-09-01

    Standard data analysis on the VESUVIO spectrometer at ISIS is carried out within the Impulse Approximation framework, making use of the West scaling variable y. The experiments are performed using the time-of-flight technique with the detectors positioned at constant scattering angles. Line shape analysis is routinely performed in the y-scaling framework, using two different (and equivalent) approaches: (1) fitting the parameters of the recoil peaks directly to fixed-angle time-of-flight spectra; (2) transforming the time-of-flight spectra into fixed-angle y spectra, referred to as the Neutron Compton Profiles, and then fitting the line shape parameters. The present work shows that scattering signals from different fixed-angle detectors can be collected and rebinned to obtain Neutron Compton Profiles at constant wave vector transfer, q, allowing for a suitable interpretation of data in terms of the dynamical structure factor, S(q,{omega}). The current limits of applicability of such a procedure are discussed in terms of the available q-range and relative uncertainties for the VESUVIO experimental set up and of the main approximations involved.

  4. Constant-q data representation in Neutron Compton scattering on the VESUVIO spectrometer

    International Nuclear Information System (INIS)

    Senesi, R.; Pietropaolo, A.; Andreani, C.

    2008-01-01

    Standard data analysis on the VESUVIO spectrometer at ISIS is carried out within the Impulse Approximation framework, making use of the West scaling variable y. The experiments are performed using the time-of-flight technique with the detectors positioned at constant scattering angles. Line shape analysis is routinely performed in the y-scaling framework, using two different (and equivalent) approaches: (1) fitting the parameters of the recoil peaks directly to fixed-angle time-of-flight spectra; (2) transforming the time-of-flight spectra into fixed-angle y spectra, referred to as the Neutron Compton Profiles, and then fitting the line shape parameters. The present work shows that scattering signals from different fixed-angle detectors can be collected and rebinned to obtain Neutron Compton Profiles at constant wave vector transfer, q, allowing for a suitable interpretation of data in terms of the dynamical structure factor, S(q,ω). The current limits of applicability of such a procedure are discussed in terms of the available q-range and relative uncertainties for the VESUVIO experimental set up and of the main approximations involved

  5. Beam-helicity asymmetry arising from deeply virtual Compton scattering measured with kinematically complete event reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Airapetian, A. [Giessen Univ. (Germany). Physikalisches Inst.; Michigan Univ., Ann Arbor, MI (United States). Randall Lab. of Physics; Akopov, N. [Yerevan Physics Inst. (Armenia); Akopov, Z. [DESY, Hamburg (DE)] (and others)

    2012-06-15

    The beam-helicity asymmetry in exclusive electroproduction of real photons by the longitudinally polarized HERA positron beam scattering off an unpolarized hydrogen target is measured at HERMES. The asymmetry arises from deeply virtual Compton scattering and its interference with the Bethe-Heitler process. Azimuthal amplitudes of the beam-helicity asymmetry are extracted from a data sample consisting of ep{yields}ep{gamma} events with detection of all particles in the final state including the recoiling proton. The installation of a recoil detector, while reducing the acceptance of the experiment, allows the elimination of resonant background that was estimated to contribute an average of about 12% to the signal in previous HERMES publications. The removal of the resonant background from the present data sample is shown to increase the magnitude of the leading asymmetry amplitude by 0.054{+-}0.016 to -0.328{+-}0.027(stat.){+-}0.045(syst.).

  6. Measurement of azimuthal asymmetries associated with deeply virtual Compton scattering on an unpolarized deuterium target

    Energy Technology Data Exchange (ETDEWEB)

    Airapetian, A. [Physikalisches Institut, Universitaet Giessen, 35392 Giessen (Germany); Randall Laboratory of Physics, University of Michigan, Ann Arbor, MI 48109-1040 (United States); Akopov, N. [Yerevan Physics Institute, 375036 Yerevan (Armenia); Akopov, Z. [DESY, 22603 Hamburg (Germany); Amarian, M.; Aschenauer, E.C. [DESY, 15738 Zeuthen (Germany); Augustyniak, W. [Andrzej Soltan Institute for Nuclear Studies, 00-689 Warsaw (Poland); Avakian, R.; Avetissian, A. [Yerevan Physics Institute, 375036 Yerevan (Armenia); Avetisyan, E. [DESY, 22603 Hamburg (Germany); Ball, B. [Randall Laboratory of Physics, University of Michigan, Ann Arbor, MI 48109-1040 (United States); Belostotski, S. [Petersburg Nuclear Physics Institute, Gatchina, Leningrad region 188300 (Russian Federation); Bianchi, N. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati, 00044 Frascati (Italy); Blok, H.P. [National Institute for Subatomic Physics (Nikhef), 1009 DB Amsterdam (Netherlands); Department of Physics, VU University, 1081 HV Amsterdam (Netherlands); Boettcher, H. [DESY, 15738 Zeuthen (Germany); Borissov, A. [DESY, 22603 Hamburg (Germany); Bowles, J. [Department of Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ (United Kingdom); Bryzgalov, V. [Institute for High Energy Physics, Protvino, Moscow region 142281 (Russian Federation); Burns, J. [Department of Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ (United Kingdom); Capiluppi, M. [Istituto Nazionale di Fisica Nucleare, Sezione di Ferrara and Dipartimento di Fisica, Universita di Ferrara, 44100 Ferrara (Italy); Capitani, G.P. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati, 00044 Frascati (Italy)

    2010-04-11

    Azimuthal asymmetries in exclusive electroproduction of a real photon from an unpolarized deuterium target are measured with respect to beam helicity and charge. They appear in the distribution of these photons in the azimuthal angle phi around the virtual-photon direction, relative to the lepton scattering plane. The extracted asymmetries are attributed to either the deeply virtual Compton scattering process or its interference with the Bethe-Heitler process. They are compared with earlier results on the proton target. In the measured kinematic region, the beam-charge asymmetry amplitudes and the leading amplitudes of the beam-helicity asymmetries on an unpolarized deuteron target are compatible with the results from unpolarized protons.

  7. Compton scattering for spectroscopic detection of ultra-fast, high flux, broad energy range X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Cipiccia, S.; Wiggins, S. M.; Brunetti, E.; Vieux, G.; Yang, X.; Welsh, G. H.; Anania, M.; Islam, M. R.; Ersfeld, B.; Jaroszynski, D. A. [Scottish Universities Physics Alliance, Department of Physics, University of Strathclyde, John Anderson Building, 107 Rottenrow, Glasgow G4 0NG (United Kingdom); Maneuski, D.; Montgomery, R.; Smith, G.; Hoek, M.; Hamilton, D. J.; Shea, V. O. [Scottish Universities Physics Alliance, School of Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ (United Kingdom); Issac, R. C. [Scottish Universities Physics Alliance, Department of Physics, University of Strathclyde, John Anderson Building, 107 Rottenrow, Glasgow G4 0NG (United Kingdom); Research Department of Physics, Mar Athanasius College, Kothamangalam 686666, Kerala (India); Lemos, N. R. C.; Dias, J. M. [GoLP/Instituto de Plasmas eFusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, Avenida Rovisco Pais, 1049-001 Lisbon (Portugal); Symes, D. R. [Central Laser Facility, Science and Technology Facilities Council, Rutherford Appleton Laboratory, Harwell Science and Innovation Campus, OX11 0QX Didcot (United Kingdom); and others

    2013-11-15

    Compton side-scattering has been used to simultaneously downshift the energy of keV to MeV energy range photons while attenuating their flux to enable single-shot, spectrally resolved, measurements of high flux X-ray sources to be undertaken. To demonstrate the technique a 1 mm thick pixelated cadmium telluride detector has been used to measure spectra of Compton side-scattered radiation from a Cobalt-60 laboratory source and a high flux, high peak brilliance X-ray source of betatron radiation from a laser-plasma wakefield accelerator.

  8. On the distribution of electrons in the double ionization of helium-like ions by Compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Amusia, M Ya [Racah Institute of Physics, Hebrew University, Jerusalem 91904 (Israel); Drukarev, E G [Petersburg Nuclear Physics Institute, Gatchina, St Petersburg 188300 (Russian Federation)

    2003-06-28

    The Compton scattering of a high energy photon by a helium-like ion, followed by the ionization of two electrons, is considered outside of the Bethe surface of Compton scattering with the knock-out of a single electron. The role of shake-off (SO), of final state interactions (FSI) and of the quasi-free mechanism (QFM) is analysed. The triple and double differential distributions are calculated. It is demonstrated for the first time that in certain kinematical regions the process is dominated by the FSI and by the QFM, while the SO contribution is much smaller.

  9. Measurement of the Proton Structure Function $F_{2}$ at low $Q^{2}$ in QED Compton Scattering at HERA

    CERN Document Server

    Aktas, A.; Anthonis, T.; Asmone, A.; Babaev, A.; Backovic, S.; Bahr, J.; Baranov, P.; Barrelet, E.; Bartel, W.; Baumgartner, S.; Becker, J.; Beckingham, M.; Behnke, O.; Behrendt, O.; Belousov, A.; Berger, Ch.; Berger, N.; Berndt, T.; Bizot, J.C.; Bohme, J.; Boenig, M.-O.; Boudry, V.; Bracinik, J.; Brisson, V.; Broker, H.-B.; Brown, D.P.; Bruncko, D.; Busser, F.W.; Bunyatyan, A.; Buschhorn, G.; Bystritskaya, L.; Campbell, A.J.; Caron, S.; Cassol-Brunner, F.; Cerny, K.; Chekelian, V.; Collard, C.; Contreras, J.G.; Coppens, Y.R.; Coughlan, J.A.; Cox, B.E.; Cozzika, G.; Cvach, J.; Dainton, J.B.; Dau, W.D.; Daum, K.; Delcourt, B.; Demirchyan, R.; De Roeck, A.; Desch, K.; De Wolf, E.A.; Diaconu, C.; Dingfelder, J.; Dodonov, V.; Dubak, A.; Duprel, C.; Eckerlin, Guenter; Efremenko, V.; Egli, S.; Eichler, R.; Eisele, F.; Ellerbrock, M.; Elsen, E.; Erdmann, M.; Erdmann, W.; Faulkner, P.J.W.; Favart, L.; Fedotov, A.; Felst, R.; Ferencei, J.; Fleischer, M.; Fleischmann, P.; Fleming, Y.H.; Flucke, G.; Flugge, G.; Fomenko, A.; Foresti, I.; Formanek, J.; Franke, G.; Frising, G.; Gabathuler, E.; Gabathuler, K.; Garutti, E.; Garvey, J.; Gayler, J.; Gerhards, R.; Gerlich, C.; Ghazaryan, Samvel; Goerlich, L.; Gogitidze, N.; Gorbounov, S.; Grab, C.; Grassler, H.; Greenshaw, T.; Gregori, M.; Grindhammer, Guenter; Gwilliam, C.; Haidt, D.; Hajduk, L.; Haller, J.; Hansson, M.; Heinzelmann, G.; Henderson, R.C.W.; Henschel, H.; Henshaw, O.; Heremans, R.; Herrera, G.; Herynek, I.; Heuer, R.-D.; Hildebrandt, M.; Hiller, K.H.; Hoting, P.; Hoffmann, D.; Horisberger, R.; Hovhannisyan, A.; Ibbotson, M.; Ismail, M.; Jacquet, M.; Janauschek, L.; Janssen, X.; Jemanov, V.; Jonsson, L.; Johnson, D.P.; Jung, H.; Kant, D.; Kapichine, M.; Karlsson, M.; Katzy, J.; Keller, N.; Kennedy, J.; Kenyon, I.R.; Kiesling, Christian M.; Klein, M.; Kleinwort, C.; Klimkovich, T.; Kluge, T.; Knies, G.; Knutsson, A.; Koblitz, B.; Korbel, V.; Kostka, P.; Koutouev, R.; Kropivnitskaya, A.; Kroseberg, J.; Kuckens, J.; Kuhr, T.; Landon, M.P.J.; Lange, W.; Lastovicka, T.; Laycock, P.; Lebedev, A.; Leiner, B.; Lemrani, R.; Lendermann, V.; Levonian, S.; Lindfeld, L.; Lipka, K.; List, B.; Lobodzinska, E.; Loktionova, N.; Lopez-Fernandez, R.; Lubimov, V.; Lueders, H.; Luke, D.; Lux, T.; Lytkin, L.; Makankine, A.; Malden, N.; Malinovski, E.; Mangano, S.; Marage, P.; Marks, J.; Marshall, R.; Martisikova, M.; Martyn, H.-U.; Maxfield, S.J.; Meer, D.; Mehta, A.; Meier, K.; Meyer, A.B.; Meyer, H.; Meyer, J.; Michine, S.; Mikocki, S.; Milcewicz-Mika, I.; Milstead, D.; Mohamed, A.; Moreau, F.; Morozov, A.; Morozov, I.; Morris, J.V.; Mozer, Matthias Ulrich; Muller, K.; Murin, P.; Nagovizin, V.; Naroska, B.; Naumann, J.; Naumann, Th.; Newman, Paul R.; Niebuhr, C.; Nikiforov, A.; Nikitin, D.; Nowak, G.; Nozicka, M.; Oganezov, R.; Olivier, B.; Olsson, J.E.; Ossoskov, G.; Ozerov, D.; Pascaud, C.; Patel, G.D.; Peez, M.; Perez, E.; Perieanu, A.; Petrukhin, A.; Pitzl, D.; Placakyte, R.; Poschl, R.; Portheault, B.; Povh, B.; Raicevic, N.; Ratiani, Z.; Reimer, P.; Reisert, B.; Rimmer, A.; Risler, C.; Rizvi, E.; Robmann, P.; Roland, B.; Roosen, R.; Rostovtsev, A.; Rurikova, Z.; Rusakov, S.; Rybicki, K.; Sankey, D.P.C.; Sauvan, E.; Schatzel, S.; Scheins, J.; Schilling, F.-P.; Schleper, P.; Schmidt, S.; Schmitt, S.; Schneider, M.; Schoeffel, L.; Schoning, A.; Schroder, V.; Schultz-Coulon, H.-C.; Schwanenberger, C.; Sedlak, K.; Sefkow, F.; Sheviakov, I.; Shtarkov, L.N.; Sirois, Y.; Sloan, T.; Smirnov, P.; Soloviev, Y.; South, D.; Spaskov, V.; Specka, Arnd E.; Spitzer, H.; Stamen, R.; Stella, B.; Stiewe, J.; Strauch, I.; Straumann, U.; Tchoulakov, V.; Thompson, Graham; Thompson, P.D.; Tomasz, F.; Traynor, D.; Truoel, Peter; Tsipolitis, G.; Tsurin, I.; Turnau, J.; Tzamariudaki, E.; Uraev, A.; Urban, Marcel; Usik, A.; Utkin, D.; Valkar, S.; Valkarova, A.; Vallee, C.; Van Mechelen, P.; Van Remortel, N.; Vargas Trevino, A.; Vazdik, Y.; Veelken, C.; Vest, A.; Vinokurova, S.; Volchinski, V.; Wacker, K.; Wagner, J.; Weber, G.; Weber, R.; Wegener, D.; Werner, C.; Werner, N.; Wessels, M.; Wessling, B.; Winter, G.-G.; Wissing, Ch.; Woehrling, E.-E.; Wolf, R.; Wunsch, E.; Xella, S.; Yan, W.; Yeganov, V.; Zacek, J.; Zalesak, J.; Zhang, Z.; Zhokin, A.; Zohrabyan, H.; Zomer, F.

    2004-01-01

    The proton structure function F_2(x,Q^2) is measured in inelastic QED Compton scattering using data collected with the H1 detector at HERA. QED Compton events are used to access the kinematic range of very low virtualities of the exchanged photon, Q^2, down to 0.5 GeV^2, and Bjorken x up to \\sim 0.06, a region which has not been covered previously by inclusive measurements at HERA. The results are in agreement with the measurements from fixed target lepton-nucleon scattering experiments.

  10. Study of electron densities of normal and neoplastic human breast tissues by Compton scattering using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Antoniassi, M.; Conceicao, A.L.C. [Departamento de Fisica-Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto-Universidade de Sao Paulo, Ribeirao Preto, Sao Paulo (Brazil); Poletti, M.E., E-mail: poletti@ffclrp.usp.br [Departamento de Fisica-Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto-Universidade de Sao Paulo, Ribeirao Preto, Sao Paulo (Brazil)

    2012-07-15

    Electron densities of 33 samples of normal (adipose and fibroglangular) and neoplastic (benign and malignant) human breast tissues were determined through Compton scattering data using a monochromatic synchrotron radiation source and an energy dispersive detector. The area of Compton peaks was used to determine the electron densities of the samples. Adipose tissue exhibits the lowest values of electron density whereas malignant tissue the highest. The relationship with their histology was discussed. Comparison with previous results showed differences smaller than 4%. - Highlights: Black-Right-Pointing-Pointer Electron density of normal and neoplastic breast tissues was measured using Compton scattering. Black-Right-Pointing-Pointer Monochromatic synchrotron radiation was used to obtain the Compton scattering data. Black-Right-Pointing-Pointer The area of Compton peaks was used to determine the electron densities of samples. Black-Right-Pointing-Pointer Adipose tissue shows the lowest electron density values whereas the malignant tissue the highest. Black-Right-Pointing-Pointer Comparison with previous results showed differences smaller than 4%.

  11. Effect of detector collimator and sample thickness on 0.662 MeV multiply Compton-scattered gamma rays

    International Nuclear Information System (INIS)

    Singh, Manpreet; Singh, Gurvinderjit; Sandhu, B.S.; Singh, Bhajan

    2006-01-01

    The simultaneous effect of detector collimator and sample thickness on 0.662 MeV multiply Compton-scattered gamma photons was studied experimentally. An intense collimated beam, obtained from 6-Ci 137 Cs source, is allowed to impinge on cylindrical aluminium samples of varying diameter and the scattered photons are detected by a 51 mmx51 mm NaI(Tl) scintillation detector placed at 90 o to the incident beam. The full energy peak corresponding to singly scattered events is reconstructed analytically. The thickness at which the multiply scattered events saturate is determined for different detector collimators. The parameters like signal-to-noise ratio and multiply scatter fraction (MSF) have also been deduced and support the work carried out by Shengli et al. [2000. EGS4 simulation of Compton scattering for nondestructive testing. KEK proceedings 200-20, Tsukuba, Japan, pp. 216-223] and Barnea et al. [1995. A study of multiple scattering background in Compton scatter imaging. NDT and E International 28, 155-162] based upon Monte Carlo calculations

  12. Virtual Compton Scattering at MAMI and measurement of the proton generalized polarizabilities

    International Nuclear Information System (INIS)

    Roche, Julie

    1998-01-01

    We have measured the absolute unpolarized cross sections for photon electro-production of the proton with the Three-Spectrometer-Setup at MAMI at a momentum transfer q=600 MeV (or squared quadra-momentum of the virtual photon 0.33 GeV square) and a virtual photon polarization 0.62. The momentum for the outgoing real photon q' ranged from 33 to 111 MeV. We extracted two combinations of the generalized polarizabilities (GPs) of the proton. The reaction of interest is Virtual Compton Scattering off the proton. We can access to a measurement of the rigidity of the internal structure of the nucleon. Below pion production threshold but arbitrary squared quadra-momentum of the virtual photon, measured observables are the GPs. They generalize the concept of electric and magnetic polarizabilities already defined in Real Compton Scattering. Experimentally, the scattered electron was detected in coincidence with the recoiling proton in two high-resolution spectrometers. The photon emission process was selected by a cut on the missing mass squared distribution around zero. This PhD work describes the analysis work from raw data to absolute and precise cross sections (within a 3 pc statistical and 4 pc systematic accuracies). Our experiment at Mainz demonstrates that it is possible to measure two structure functions related to the GPs; extracted values are presented. These observables are compared with theoretical predictions and are very efficient to disentangle models of the non-perturbative structure of the nucleon. (author) [fr

  13. Measurement of azimuthal asymmetries associated with deeply virtual Compton scattering on a longitudinally polarized deuterium target

    Energy Technology Data Exchange (ETDEWEB)

    Airapetian, A. [Physikalisches Institut, Universitaet Giessen, 35392 Giessen (Germany)] [Randall Laboratory of Physics, University of Michigan, Ann Arbor, MI 48109-1040 (United States); Akopov, N. [Yerevan Physics Institute, 375036 Yerevan (Armenia); Akopov, Z. [DESY, 22603 Hamburg (Germany); Aschenauer, E.C. [DESY, 15738 Zeuthen (Germany); Augustyniak, W. [Andrzej Soltan Institute for Nuclear Studies, 00-689 Warsaw (Poland); Avakian, R.; Avetissian, A. [Yerevan Physics Institute, 375036 Yerevan (Armenia); Avetisyan, E. [DESY, 22603 Hamburg (Germany); Belostotski, S. [Petersburg Nuclear Physics Institute, Gatchina, Leningrad region 188300 (Russian Federation); Bianchi, N. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati, 00044 Frascati (Italy); Blok, H.P. [National Institute for Subatomic Physics (Nikhef), 1009 DB Amsterdam (Netherlands)] [Department of Physics and Astronomy, VU University, 1081 HV Amsterdam (Netherlands); Borissov, A. [DESY, 22603 Hamburg (Germany); Bowles, J. [Department of Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ (United Kingdom); Brodski, I. [Physikalisches Institut, Universitaet Giessen, 35392 Giessen (Germany); Bryzgalov, V. [Institute for High Energy Physics, Protvino, Moscow region 142281 (Russian Federation); Burns, J. [Department of Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ (United Kingdom); Capiluppi, M. [Istituto Nazionale di Fisica Nucleare, Sezione di Ferrara and Dipartimento di Fisica, Universita di Ferrara, 44100 Ferrara (Italy); Capitani, G.P. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati, 00044 Frascati (Italy); Cisbani, E. [Istituto Nazionale di Fisica Nucleare, Sezione Roma 1, Gruppo Sanita and Physics Laboratory, Istituto Superiore di Sanita, 00161 Roma (Italy); Ciullo, G. [Istituto Nazionale di Fisica Nucleare, Sezione di Ferrara and Dipartimento di Fisica, Universita di Ferrara, 44100 Ferrara (Italy)

    2011-01-21

    Azimuthal asymmetries in exclusive electroproduction of a real photon from a longitudinally polarized deuterium target are measured with respect to target polarization alone and with respect to target polarization combined with beam helicity and/or beam charge. The asymmetries appear in the distribution of the real photons in the azimuthal angle {phi} around the virtual photon direction, relative to the lepton scattering plane. The asymmetries arise from the deeply virtual Compton scattering process and its interference with the Bethe-Heitler process. The results for the beam-charge and beam-helicity asymmetries from a tensor polarized deuterium target with vanishing vector polarization are shown to be compatible with those from an unpolarized deuterium target, which is expected for incoherent scattering dominant at larger momentum transfer. Furthermore, the results for the single target-spin asymmetry and for the double-spin asymmetry are found to be compatible with the corresponding asymmetries previously measured on a hydrogen target. For coherent scattering on the deuteron at small momentum transfer to the target, these findings imply that the tensor contribution to the cross section is small. Furthermore, the tensor asymmetry is found to be compatible with zero.

  14. Scaling laws in high-energy inverse compton scattering. II. Effect of bulk motions

    International Nuclear Information System (INIS)

    Nozawa, Satoshi; Kohyama, Yasuharu; Itoh, Naoki

    2010-01-01

    We study the inverse Compton scattering of the CMB photons off high-energy nonthermal electrons. We extend the formalism obtained by the previous paper to the case where the electrons have nonzero bulk motions with respect to the CMB frame. Assuming the power-law electron distribution, we find the same scaling law for the probability distribution function P 1,K (s) as P 1 (s) which corresponds to the zero bulk motions, where the peak height and peak position depend only on the power-index parameter. We solved the rate equation analytically. It is found that the spectral intensity function also has the same scaling law. The effect of the bulk motions to the spectral intensity function is found to be small. The present study will be applicable to the analysis of the x-ray and gamma-ray emission models from various astrophysical objects with nonzero bulk motions such as radio galaxies and astrophysical jets.

  15. Brilliant GeV gamma-ray flash from inverse Compton scattering in the QED regime

    Science.gov (United States)

    Gong, Z.; Hu, R. H.; Lu, H. Y.; Yu, J. Q.; Wang, D. H.; Fu, E. G.; Chen, C. E.; He, X. T.; Yan, X. Q.

    2018-04-01

    An all-optical scheme is proposed for studying laser plasma based incoherent photon emission from inverse Compton scattering in the quantum electrodynamic regime. A theoretical model is presented to explain the coupling effects among radiation reaction trapping, the self-generated magnetic field and the spiral attractor in phase space, which guarantees the transfer of energy and angular momentum from electromagnetic fields to particles. Taking advantage of a prospective ∼ 1023 W cm‑2 laser facility, 3D particle-in-cell simulations show a gamma-ray flash with unprecedented multi-petawatt power and brightness of 1.7 × 1023 photons s‑1 mm‑2 mrad‑2/0.1% bandwidth (at 1 GeV). These results bode well for new research directions in particle physics and laboratory astrophysics exploring laser plasma interactions.

  16. Laser-Wakefield driven compact Compton scattering gamma-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Albert, F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Froula, D. H. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hartemann, F. V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Joshi, C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2010-04-13

    We propose to demonstrate a novel x-ray and gamma-ray light source based on laser-plasma electron acceleration and Compton scattering at the Jupiter Laser Facility at LLNL. This will provide a new versatile and compact light source capability at the laboratory with very broad scientific applications that are of interest to many disciplines. The source’s synchronization with the seed laser system at a femtosecond time scale (i-e, at which chemical reactions occur) will allow scientists to perform pump-probe experiments with x-ray and gamma-ray beams. Across the laboratory, this will be a new tool for nuclear science, high energy density physics, chemistry, biology, or weapons studies.

  17. Research on application of CNN in Compton back-scattering image processing

    International Nuclear Information System (INIS)

    Wang Huaiying; Yang Lirui; Zhang Yujin

    2010-01-01

    A cellular neural network (CNN) is a large-scale nonlinear analog circuit suitable for real-time signal and image processing. CNN can be used for high-speed parallel computation and is easy to be translated into a VLSI implementation. This paper presents one new approach for Compton back-scattering (CBS) image filter and segmentation using CNN. Furthermore presents one new way for eliminating isolated point on CNN and morphologic method. CNN Some practical results are presented and briefly discussed, which demonstrates the successful operation of the proposed algorithm. Those new approaches is very affordable to parallelism and analog VLSI implementation, which allowing the CBS image processing to be performed in real-time. (authors)

  18. Measurements of Compton Scattering on the Proton at 2 - 6 GeV

    Energy Technology Data Exchange (ETDEWEB)

    Danagoulian, Areg [Univ. of Illinois, Urbana-Champaign, IL (United States)

    2006-01-01

    Similar to elastic electron scattering, Compton Scattering on the proton at high momentum transfers(and high p⊥) can be an effective method to study its short-distance structure. An experiment has been carried out to measure the cross sections for Real Compton Scattering (RCS) on the proton for 2.3-5.7 GeV electron beam energies and a wide distribution of large scattering angles. The 25 kinematic settings sampled a domain of s = 5-11(GeV/c)2,-t = -7(GeV/c)2 and -u = 0.5-6.5(GeV/c)2. In addition, a measurement of longitudinal and transverse polarization transfer asymmetries was made at a 3.48 GeV beam energy and a scattering angle of θcm = 120°. These measurements were performed to test the existing theoretical mechanisms for this process as well as to determine RCS form factors. At the heart of the scientific motivation is the desire to understand the manner in which a nucleon interacts with external excitations at the above listed energies, by comparing and contrasting the two existing models – Leading Twist Mechanism and Soft Overlap “Handbag” Mechanism – and identify the dominant mechanism. Furthermore, the Handbag Mechanism allows one to calculate reaction observables in the framework of Generalized Parton Distributions (GPD), which have the function of bridging the wide gap between the exclusive(form factors) and inclusive(parton distribution functions) description of the proton. The experiment was conducted in Hall A of Thomas Jefferson National Accelerator Facility(Jefferson Lab). It used a polarized and unpolarized electron beam, a 6% copper radiator with the thickness of 6.1% radiation lengths (to produce a bremsstrahlung photon beam), the Hall A liquid hydrogen target, a high resolution spectrometer with a focal plane polarimeter, and a photon hodoscope calorimeter. Results of the differential cross sections are presented, and discussed in the general context of the scientific motivation.

  19. Deeply virtual Compton scattering with the CLAS detector for the study of generalized parton distributions

    International Nuclear Information System (INIS)

    Girod, F.X.

    2006-12-01

    The structure of the nucleon, among the first fundamental problems in hadronic physics, is the subject of a renewed interest. The lightest baryonic state has historically been described in two complementary approaches: through elastic scattering, measuring form factors which reflect the spatial shape of charge distributions, and through deep inelastic scattering, providing access to parton distribution functions which encode the momentum content carried by the constituents. The recently developed formalism of Generalized Parton Distributions unifies those approaches and provides access to new informations. The cleanest process sensitive to GPDs is the deeply virtual Compton scattering (DVCS) contributing to the ep → epγ reaction. This work deals with a dedicated experiment accomplished with the CLAS detector, completed with two specific equipments: a lead tungstate calorimeter covering photon detection at small angles, and a superconducting solenoid actively shielding the electromagnetic background. The entire project is covered: from the upgrade of the experimental setup, through the update of the software, data taking and analysis, up to a first comparison of the beam spin asymmetry to model predictions. (author)

  20. Compact FEL-driven inverse compton scattering gamma-ray source

    Energy Technology Data Exchange (ETDEWEB)

    Placidi, M. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Di Mitri, S., E-mail: simone.dimitri@elettra.eu [Elettra - Sincrotrone Trieste S.C.p.A., 34149 Basovizza, Trieste (Italy); Pellegrini, C. [SLAC National Accelerator Laboratory, Menlo Park, CA 94025 (United States); University of California, Los Angeles, CA 90095 (United States); Penn, G. [Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States)

    2017-05-21

    Many research and applications areas require photon sources capable of producing gamma-ray beams in the multi-MeV energy range with reasonably high fluxes and compact footprints. Besides industrial, nuclear physics and security applications, a considerable interest comes from the possibility to assess the state of conservation of cultural assets like statues, columns etc., via visualization and analysis techniques using high energy photon beams. Computed Tomography scans, widely adopted in medicine at lower photon energies, presently provide high quality three-dimensional imaging in industry and museums. We explore the feasibility of a compact source of quasi-monochromatic, multi-MeV gamma-rays based on Inverse Compton Scattering (ICS) from a high intensity ultra-violet (UV) beam generated in a free-electron laser by the electron beam itself. This scheme introduces a stronger relationship between the energy of the scattered photons and that of the electron beam, resulting in a device much more compact than a classic ICS for a given scattered energy. The same electron beam is used to produce gamma-rays in the 10–20 MeV range and UV radiation in the 10–15 eV range, in a ~4×22 m{sup 2} footprint system.

  1. Strong-field QED processes in short laser pulses. One- and two-photon Compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Seipt, Daniel

    2012-12-20

    The purpose of this thesis is to advance the understanding of strong-field QED processes in short laser pulses. The processes of non-linear one-photon and two-photon Compton scattering are studied, that is the scattering of photons in the interaction of relativistic electrons with ultra-short high-intensity laser pulses. These investigations are done in view of the present and next generation of ultra-high intensity optical lasers which are supposed to achieve unprecedented intensities of the order of 10{sup 24} W/cm{sup 2} and beyond, with pulse lengths in the order of some femtoseconds. The ultra-high laser intensity requires a non-perturbative description of the interaction of charged particles with the laser field to allow for multi-photon interactions, which is beyond the usual perturbative expansion of QED organized in powers of the fine structure constant. This is achieved in strong-field QED by employing the Furry picture and non-perturbative solutions of the Dirac equation in the presence of a background laser field as initial and final state wave functions, as well as the laser dressed Dirac-Volkov propagator. The primary objective is a realistic description of scattering processes with regard to the finite laser pulse duration beyond the common approximation of infinite plane waves, which is made necessary by the ultra-short pulse length of modern high-intensity lasers. Non-linear finite size effects are identified, which are a result of the interplay between the ultra-high intensity and the ultra-short pulse length. In particular, the frequency spectra and azimuthal photon emission spectra are studied emphasizing the differences between pulsed and infinite laser fields. The proper description of the finite temporal duration of the laser pulse leads to a regularization of unphysical infinities (due to the infinite plane-wave description) of the laser-dressed Dirac-Volkov propagator and in the second-order strong-field process of two-photon Compton

  2. Strong-field QED processes in short laser pulses. One- and two-photon Compton scattering

    International Nuclear Information System (INIS)

    Seipt, Daniel

    2012-01-01

    The purpose of this thesis is to advance the understanding of strong-field QED processes in short laser pulses. The processes of non-linear one-photon and two-photon Compton scattering are studied, that is the scattering of photons in the interaction of relativistic electrons with ultra-short high-intensity laser pulses. These investigations are done in view of the present and next generation of ultra-high intensity optical lasers which are supposed to achieve unprecedented intensities of the order of 10 24 W/cm 2 and beyond, with pulse lengths in the order of some femtoseconds. The ultra-high laser intensity requires a non-perturbative description of the interaction of charged particles with the laser field to allow for multi-photon interactions, which is beyond the usual perturbative expansion of QED organized in powers of the fine structure constant. This is achieved in strong-field QED by employing the Furry picture and non-perturbative solutions of the Dirac equation in the presence of a background laser field as initial and final state wave functions, as well as the laser dressed Dirac-Volkov propagator. The primary objective is a realistic description of scattering processes with regard to the finite laser pulse duration beyond the common approximation of infinite plane waves, which is made necessary by the ultra-short pulse length of modern high-intensity lasers. Non-linear finite size effects are identified, which are a result of the interplay between the ultra-high intensity and the ultra-short pulse length. In particular, the frequency spectra and azimuthal photon emission spectra are studied emphasizing the differences between pulsed and infinite laser fields. The proper description of the finite temporal duration of the laser pulse leads to a regularization of unphysical infinities (due to the infinite plane-wave description) of the laser-dressed Dirac-Volkov propagator and in the second-order strong-field process of two-photon Compton scattering. An

  3. A new data treatment scheme for integrated intensities in neutron Compton scattering

    International Nuclear Information System (INIS)

    Krzystyniak, M; Chatzidimitriou-Dreismann, C A

    2008-01-01

    A new data reduction scheme is presented for time-of-flight data collected in neutron Compton scattering experiments with the aim of obtaining the scattering intensities. The method proposed is a single number approach as it makes use of the count rates detected in the individual time-of-flight channels. The most convenient seems to be the variant of the method where time-of-flight channels are chosen corresponding to centers of recoil peaks of individual masses. With such a choice of time-of-flight channels, the method presented is more robust against unwanted background signals and noise than the method widely used in NCS studies based on fitting entire time-of-flight band shapes in the framework of the convolution approximation. Moreover, it should perform better than the model-free Dorner method as it does not require the numerical integration of the signal, which is also sensitive to baseline and noise. As an example of the performance of the new method, polyethylene data are treated and compared to results obtained previously using conventional data reduction and the model-free method proposed by Dorner. It is shown that all three data reduction schemes lead to the same results for the scattering intensities of protons in polyethylene, thus strengthening the conclusion about the anomalous scattering cross-section of protons in this substance. In the future the new data reduction scheme can be used to treat the data from other experiments where the conventional NCS data treatment and/or Dorner method fail due to noise and/or unwanted background signals present in the time-of-flight spectra

  4. Proposal to determine the Fermi-surface topology of a doped iron-based superconductor using bulk-sensitive Fourier-transform Compton scattering

    NARCIS (Netherlands)

    Wang, Y.J.; Lin, H.; Barbiellini, B.; Mijnarends, P.E.; Kaprzyk, S.; Markiewicz, R.S.; Bansil, A.

    2010-01-01

    We have carried out first-principles calculations of the Compton scattering spectra to demonstrate that the filling of the hole Fermi surface in LaO1?xFxFeAs produces a distinct signature in the Fourier-transformed Compton spectrum when the momentum transfer vector lies along the [100] direction. We

  5. Inverse Compton Scattering as a Diagnostic Tool for the Measurement of Electron Beam Energies in Diodes

    Science.gov (United States)

    Critchley, A. D. J.

    2003-10-01

    The main emphasis of the diode research project at the Atomic Weapons Establishment (AWE) UK is to produce small diameter radiographic spot sizes at high dose to improve the resolution of the transmission radiographs taken during hydrodynamic experiments. Experimental measurements of conditions within the diodes of Pulsed Power driven flash x-ray machines are vital to provide a benchmark for electromagnetic PIC codes such as LSP which are used to develop new diode designs. The potential use of inverse Compton scattering (ICS) as a diagnostic technique in the determination of electron energies within the diode has been investigated. The interaction of a laser beam with a beam of high-energy electrons will create an ICS spectrum of photons. Theoretically, one should be able to glean information on the energies and positions of the electrons from the energy spectrum and differential cross section of the scattered photons. The feasibility of fielding this technique on various diode designs has been explored, and an experimental setup with the greatest likelihood of success is proposed.

  6. Optimal sum-rule inequalities for spin 1/2 Compton scattering. III

    International Nuclear Information System (INIS)

    Filkov, L.V.

    1980-10-01

    The analyticity (optimal) bounds for proton Compton scattering presented in the preceding paper are herewith considered from the point of view of experimental tests. An essential function occuring in this new dispersion framework is constructed numerically making use of existing cross-section data above the pion photoproduction threshold. To secure a safer construction new measurements in the photon laboratory energy region 150 MeV - 240 MeV and at small momentum transfers are necessary. The bounds on the scattering amplitudes in the low energy region below the pion photoproduction threshold are in general sufficiently restrictive so as to be useful in discriminating among variants of theoretical phenomenological analyses but subsequent extremizations needed in bounding only one combination of the amplitudes (the unpolarized differential cross-section) are weakening much the results. The question of strengthening the bounds by means of the combined use of analyticity and unitarity is discussed within a very crude example which nonetheless illustrates that the inclusion of the pion photoproduction data through more elaborate mathematical procedures would deserve the effort. (author)

  7. The HERMES recoil photon detector and the study of deeply virtual Compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Hulse, Charlotte van

    2011-03-15

    The study of deeply virtual Compton scattering (DVCS) gives information about the contribution of the quark orbital angular momentum to the spin of the proton. DVCS has been studied at the HERMES experiment at DESY in Hamburg. Here 27.6 GeV longitudinally polarized electrons and positrons were scattered off a gaseous proton target. For the analysis of DVCS the recoiling proton could not be detected, but was reconstructed via its missing mass. This method suffers, however, from a 14% background contribution, mainly originating from associated DVCS. In this process the proton does not stay in its ground state but is excited to a {delta}{sup +} resonance. In order to reduce the background contribution down to less than 1%, a recoil detector was installed in the HERMES experiment beginning of 2006. This detector consists of three subcomponents, of which one is the photon detector. The main function of the photon detector is the detection of {delta}{sup +} decay photons. The photon detector was started up and commissioned for the analysis of (associated) DVCS. Subsequently DVCS and associated DVCS were analyzed using the recoil detector. (orig.)

  8. X-band RF gun and linac for medical Compton scattering X-ray source

    Science.gov (United States)

    Dobashi, Katsuhito; Uesaka, Mitsuru; Fukasawa, Atsushi; Sakamoto, Fumito; Ebina, Futaro; Ogino, Haruyuki; Urakawa, Junji; Higo, Toshiyasu; Akemoto, Mitsuo; Hayano, Hitoshi; Nakagawa, Keiichi

    2004-12-01

    Compton scattering hard X-ray source for 10-80 keV are under construction using the X-band (11.424 GHz) electron linear accelerator and YAG laser at Nuclear Engineering Research laboratory, University of Tokyo. This work is a part of the national project on the development of advanced compact medical accelerators in Japan. National Institute for Radiological Science is the host institute and U.Tokyo and KEK are working for the X-ray source. Main advantage is to produce tunable monochromatic hard (10-80 keV) X-rays with the intensities of 108-1010 photons/s (at several stages) and the table-top size. Second important aspect is to reduce noise radiation at a beam dump by adopting the deceleration of electrons after the Compton scattering. This realizes one beamline of a 3rd generation SR source at small facilities without heavy shielding. The final goal is that the linac and laser are installed on the moving gantry. We have designed the X-band (11.424 GHz) traveling-wave-type linac for the purpose. Numerical consideration by CAIN code and luminosity calculation are performed to estimate the X-ray yield. X-band thermionic-cathode RF-gun and RDS(Round Detuned Structure)-type X-band accelerating structure are applied to generate 50 MeV electron beam with 20 pC microbunches (104) for 1 microsecond RF macro-pulse. The X-ray yield by the electron beam and Q-switch Nd:YAG laser of 2 J/10 ns is 107 photons/RF-pulse (108 photons/sec at 10 pps). We design to adopt a technique of laser circulation to increase the X-ray yield up to 109 photons/pulse (1010 photons/s). 50 MW X-band klystron and compact modulator have been constructed and now under tuning. The construction of the whole system has started. X-ray generation and medical application will be performed in the early next year.

  9. Electron momentum distribution of BaZrO3 using Compton scattering technique

    International Nuclear Information System (INIS)

    Sharma, Sonu; Mund, H.S.; Sahariya, Jagrati; Ahuja, B.L.; Tiwari, Shailja

    2013-01-01

    In this paper, the first ever experimental Compton profile of BaZrO 3 has been measured using 20 Ci 137 Cs Compton spectrometer. To compare our experimental data, we have also computed theoretical Compton profiles using linear combination of atomic orbitals (LCAO) within the frame work of density functional theory. It is seen that the experimental Compton profile shows a better agreement with LCAO within generalised gradient approximation (GCA) than the second order correction to GCA and also hybridization of HF and density functional theory. (author)

  10. Electronic structure of CdMoO{sub 4} using Compton scattering technique

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Khushboo, E-mail: khushboo.phy@gmail.com; Ahuja, B. L. [Department of Physics, University College of Science, M.L. Sukhadia University, Udaipur-313001 (India); Sahariya, Jagrati [Department of Physics, Manipal University, Jaipur-303007 (India)

    2014-04-24

    The first ever Compton profile of polycrystalline CdMoO{sub 4} has been measured using {sup 137}Cs spectrometer. The results are compared with theoretical Compton profiles deduced from free atom and linear combination of atomic orbitals (LCAO) methods. We have also computed the energy bands using density functional theory (DFT) within LCAO. The computed bands confirm the semiconducting behaviour of this compound. It is seen that the DFT theoretical profile (with local density approximation) gives a better agreement with the experimental Compton data than free atom Compton profile.

  11. Imaging of Gamma-ray Scatter from a Polymethyl-methacrylate Phantom Using a Compton Imaging Spectrometer.

    Science.gov (United States)

    Frank, Samuel J; Kearfott, Kimberlee J

    2017-08-01

    Commercially available gamma-ray imaging spectrometers have been introduced recently and are currently undergoing investigations for various applications in nuclear power plants, environmental management, and medical environments. A Compton imaging gamma-ray spectrometer uses an array of detectors or a single position-sensitive crystal to create planar images of radionuclide distributions. The typical software included with these devices creates images of specific radionuclides using only the counts under their known gamma emission photopeaks. This approach prevents the direct imaging of scattered radiation, which is of interest for many radiation protection applications. In this paper, a technique for imaging radiation scatter or portions of the scatter spectrum is implemented. This involves the creation of a virtual radionuclide in software with peaks placed throughout the backscatter continuum of interest and then imaging that virtual radionuclide in the post-processing software. This technique is used to image the Compton scatter successfully from a polymethyl-methacrylate (PMMA) phantom placed in a Cs irradiator beam. Measured scatter energies were found to be within 15% of the expected values, sufficient to predict scatter behavior and individually measure separate sources of scatter at different angles.

  12. Corrections for the effects of accidental coincidences, Compton scatter, and object size in positron emission mammography (PEM) imaging

    Energy Technology Data Exchange (ETDEWEB)

    Raymond Raylman; Stanislaw Majewski; Randolph Wojcik; Andrew Weisenberger; Brian Kross; Vladimir Popov

    2001-06-01

    Positron emission mammography (PEM) has begun to show promise as an effective method for the detection of breast lesions. Due to its utilization of tumor-avid radiopharmaceuticals labeled with positron-emitting radionuclides, this technique may be especially useful in imaging of women with radiodense or fibrocystic breasts. While the use of these radiotracers affords PEM unique capabilities, it also introduces some limitations. Specifically, acceptance of accidental and Compton-scattered coincidence events can decrease lesion detectability. The authors studied the effect of accidental coincidence events on PEM images produced by the presence of 18F-Fluorodeoxyglucose in the organs of a subject using an anthropomorphic phantom. A delayed-coincidence technique was tested as a method for correcting PEM images for the occurrence of accidental events. Also, a Compton scatter correction algorithm designed specifically for PEM was developed and tested using a compressed breast phantom.

  13. Gamma radiation compton scattering effect from the Ukrytie Object on the radiation situation at the Chernobyl' NPP territory

    International Nuclear Information System (INIS)

    Alekseeva, E.A.; Volkovich, A.G.; Koba, G.I.; Liksonov, V.I.; Stepanov, V.E.; Tyurin, A.S.; Urutskoev, L.I.; Chesnokov, A.V.

    1989-01-01

    With the aim of determination of the angular distribution of the gamma-radiation (GR) exposure dose rate (EDR) around the Ukrytie Object (UO) are described the measurement results of GR EDR in July 1988 at the territory, adjoining to UO. The conclusion is made that the main contribution into EDR ensures GR, scattered as a result of the Compton effect on air molecules and that the contribution of the NPP territory is small. 10 figs.; 3 tabs

  14. Compton scattering spectrum as a source of information of normal and neoplastic breast tissues' composition

    Energy Technology Data Exchange (ETDEWEB)

    Antoniassi, M.; Conceicao, A.L.C. [Departamento de Fisica-Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto, Universidade de Sao Paulo, Ribeirao Preto, 14040-901 Sao Paulo (Brazil); Poletti, M.E., E-mail: poletti@ffclrp.usp.br [Departamento de Fisica-Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto, Universidade de Sao Paulo, Ribeirao Preto, 14040-901 Sao Paulo (Brazil)

    2012-07-15

    In this work we measured X-ray scatter spectra from normal and neoplastic breast tissues using photon energy of 17.44 keV and a scattering angle of 90 Degree-Sign , in order to study the shape (FWHM) of the Compton peaks. The obtained results for FWHM were discussed in terms of composition and histological characteristics of each tissue type. The statistical analysis shows that the distribution of FWHM of normal adipose breast tissue clearly differs from all other investigated tissues. Comparison between experimental values of FWHM and effective atomic number revealed a strong correlation between them, showing that the FWHM values can be used to provide information about elemental composition of the tissues. - Highlights: Black-Right-Pointing-Pointer X-ray scatter spectra from normal and neoplastic breast tissues were measured. Black-Right-Pointing-Pointer Shape (FWHM) of Compton peak was related with elemental composition and characteristics of each tissue type. Black-Right-Pointing-Pointer A statistical hypothesis test showed clear differences between normal and neoplastic breast tissues. Black-Right-Pointing-Pointer There is a strong correlation between experimental values of FWHM and effective atomic number. Black-Right-Pointing-Pointer Shape (FWHM) of Compton peak can be used to provide information about elemental composition of the tissues.

  15. Optimal sum rules inequalities for spin 1/2 Compton scattering

    International Nuclear Information System (INIS)

    Guiasu, I.; Radescu, E.E.; Razillier, I.

    1979-08-01

    A formalism appropriate for model independent dispersion theoretic investigations of the (not necessarily forward) Compton scattering off spin 1/2 hadronic targets, which fully exploits the analyticity properties of the amplitudes (to lowest order in electromagnetism) in ν 2 at fixed t(ν=(s-u)/4) s,t,u = Mandelstam variables), is developed. It relies on methods which are specific to boundary value problems for analytic matrix-valued functions. An analytic factorization of the positive definite hermitian matrix associated with the bilinear expression of the unpolarized differential cross section (u.d.c.s.) in terms of the Bardeen-Tung (B.T.) invariant amplitudes is explicitly obtained. For t in a specified portion of the physical region, six new amplitudes describing the process are thereby constructed which have the same good analyticity structure in ν 2 as the (crossing symmetrized) B.T. amplitudes, while their connection with the usual helicity amplitudes is given by a matrix which is unitary on the unitarity cut. A bound on a certain integral over the u.d.c.s. above the first inelastic threshold, established in terms of the target's charge and anomalous magnetic moment, improves a previous weaker result, being now optimal under the information accepted as known. (author)

  16. Spin Polarisabilities and Compton Scattering from χEFT: Bridging QCD and Data

    Science.gov (United States)

    Griesshammer, Harald W.; McGovern, Judith A.; Phillips, Daniel R.

    2017-01-01

    Compton scattering from protons and neutrons probes their two-photon response in electric and magnetic fields of real photons, exploring the symmetries and interaction strengths of the internal degrees of freedom. With the scalar polarisabilities αE 1 and βM 1 now reasonably understood, the focus turns to the so-far poorly explored spin-polarisabilities. They parametrise the stiffness of the nucleon spin in external electro-magnetic fields, analogous to rotations of the polarisation of light by optically active media (bi-refringence/Faraday effect) and are particularly sensitive to the directional dependence of the πNγ interactions dictated by chiral symmetry and its breaking. This contribution addresses the potential of Chiral Effective Field Theory to relate between lattice QCD and ongoing or approved efforts at MAX-lab, HI γS and MAMI. We discuss high-intensity experiments with polarised targets and polarised beams which will allow the extraction of the spin-polarisabilities; χEFT predictions which indicate which observables for polarised protons, deuterons and 3 He are particularly sensitive; convergence, residual theoretical uncertainties and possibilities for improvement; and chiral extrapolations in mπ for lattice computations. Supported in part by UK STFC, US DOE and George Washington University.

  17. Second order formalism for spin (1/2) fermions and Compton scattering

    International Nuclear Information System (INIS)

    Delgado-Acosta, E. G.; Napsuciale, Mauro; Rodriguez, Simon

    2011-01-01

    We develop a second order formalism for massive spin 1/2 fermions based on the projection over Poincare invariant subspaces in the ((1/2),0)+(0,(1/2)) representation of the homogeneous Lorentz group. Using the U(1) em gauge principle we obtain a second order description for the electromagnetic interactions of a spin 1/2 fermion with two free parameters, the gyromagnetic factor g and a parameter ξ related to odd-parity Lorentz structures. We calculate Compton scattering in this formalism. In the particular case g=2, ξ=0, and for states with well-defined parity, we recover Dirac results. In general, we find the correct classical limit and a finite value r c 2 for the forward differential cross section, independent of the photon energy and of the value of the parameters g and ξ. The differential cross section vanishes at high energies for all g, ξ except in the forward direction. The total cross section at high energies vanishes only for g=2, ξ=0. We argue that this formalism is more convenient than Dirac theory in the description of low energy electromagnetic properties of baryons and illustrate the point with the proton case.

  18. Experimental setup for deeply virtual Compton scattering (DVCS) experiment in hall A at Jefferson Laboratory

    International Nuclear Information System (INIS)

    Camsonne, A.

    2005-11-01

    The Hall A Deeply Virtual Compton Scattering (DVCS) experiment used the 5.757 GeV polarized electron beam available at Jefferson Laboratory and ran from september until december 2004. Using the standard Hall A left high resolution spectrometer three kinematical points were taken at a fixed x b (jorken) = 0.32 value for three Q 2 values: 1.5 GeV 2 , 1.91 GeV 2 , 2.32 GeV 2 . An electromagnetic Lead Fluoride calorimeter and a proton detector scintillator array designed to work at a luminosity of 10 37 cm -2 s -1 were added to ensure the exclusivity of the DVCS reaction. In addition to the new detectors new custom electronics was used: a calorimeter trigger module which determines if an electron photon coincidence has occurred and a sampling system allowing to deal with pile-up events during the offline analysis. Finally the data from the kinematic at Q 2 = 2.32 GeV 2 and s = 5.6 GeV 2 allowed to get a preliminary result for the exclusive π 0 electroproduction on the proton. (author)

  19. Coherent deeply virtual Compton scattering off 3He and neutron generalized parton distributions

    Directory of Open Access Journals (Sweden)

    Rinaldi Matteo

    2014-06-01

    Full Text Available It has been recently proposed to study coherent deeply virtual Compton scattering (DVCS off 3He nuclei to access neutron generalized parton distributions (GPDs. In particular, it has been shown that, in Impulse Approximation (IA and at low momentum transfer, the sum of the quark helicity conserving GPDs of 3He, H and E, is dominated by the neutron contribution. This peculiar result makes the 3He target very promising to access the neutron information. We present here the IA calculation of the spin dependent GPD H See Formula in PDF of 3He. Also for this quantity the neutron contribution is found to be the dominant one, at low momentum transfer. The known forward limit of the IA calculation of H See Formula in PDF , yielding the polarized parton distributions of 3He, is correctly recovered. The extraction of the neutron information could be anyway non trivial, so that a procedure, able to take into account the nuclear effects encoded in the IA analysis, is proposed. These calculations, essential for the evaluation of the coherent DVCS cross section asymmetries, which depend on the GPDs H,E and H See Formula in PDF , represent a crucial step for planning possible experiments at Jefferson Lab.

  20. Status of Kharkov X-Ray Generator Based on Compton Scattering NESTOR

    Energy Technology Data Exchange (ETDEWEB)

    Zelinsky, A.

    2005-04-11

    Nowadays the sources of the X-rays based on a storage ring with low beam energy and Compton scattering of intense laser beam are under development in several laboratories. In the paper the state-of-art in development and construction of cooperative project of a Kharkov advanced X-ray source NESTOR based on electron storage ring with beam energy 43-225 MeV and Nd:YAG laser is described. The layout of the facility is presented and latest results are described. The designed lattice includes 4 dipole magnets with combined focusing functions, 20 quadrupole magnets and 19 sextupoles with correcting components of magnetic field. At the present time a set of quadrupole magnet is under manufacturing and bending magnet reconstruction is going on. The main parameters of developed vacuum system providing residual gas pressure in the storage ring vacuum chamber up to 10{sup -9} torr are presented. The basic parameters of the X-ray source laser and injection systems are presented. The facility is going to be in operation in the middle of 2006 and generated X-rays flux is expected to be of about 10{sup 13} phot/s.

  1. Compton scattering and the gamma-ray power-law spectrum in Markarian 421

    Science.gov (United States)

    Zdziarski, Andrzej A.; Krolik, Julian H.

    1993-01-01

    The nearest BL Lac object, Mrk 421, has a gamma-ray spectrum which is approximately flat in EF-sub E from E less than about 50 MeV to E greater than about 1 TeV. Inverse Compton scattering can explain this smooth spectrum, despite the structure in the Klein-Nishina cross section, if the injected electron distribution function is proportional to gamma exp -2, where gamma is the electron Lorentz factor. When this is the case, the structure imprinted on the steady state electron distribution function by the structure in the Klein-Nishina cross section is almost exactly compensated in the radiated spectrum. Because particle acceleration in strong shocks injects particles with this distribution function, this shape injection function is in fact quite plausible. Other blazars may be explained by the same model if the cutoff below TeV energies observed in other objects is due to pair production on the cosmological IR background, as suggested by Stecker et al. (1992).

  2. Measurement of Deeply Virtual Compton Scattering and its t-dependence at HERA

    CERN Document Server

    Aaron, F.D.; Alexa, C.; Andreev, V.; Antunovic, B.; Aplin, S.; Asmone, A.; Astvatsatourov, A.; Backovic, S.; Baghdasaryan, A.; Baranov, P.; Barrelet, E.; Bartel, W.; Baudrand, S.; Beckingham, M.; Begzsuren, K.; Behnke, O.; Behrendt, O.; Belousov, A.; Berger, N.; Bizot, J.C.; Boenig, M.O.; Boudry, V.; Bozovic-Jelisavcic, I.; Bracinik, J.; Brandt, G.; Brinkmann, M.; Brisson, V.; Bruncko, D.; Busser, F.W.; Bunyatyan, A.; Buschhorn, G.; Bystritskaya, L.; Campbell, A.J.; Cantun Avila, K.B.; Cassol-Brunner, F.; Cerny, K.; Cerny, V.; Chekelian, V.; Cholewa, A.; Contreras, J.G.; Coughlan, J.A.; Cozzika, G.; Cvach, J.; Dainton, J.B.; Daum, K.; Deak, M.; de Boer, Y.; Delcourt, B.; Del Degan, M.; Delvax, J.; De Roeck, A.; De Wolf, E.A.; Diaconu, C.; Dodonov, V.; Dossanov, A.; Dubak, A.; Eckerlin, G.; Efremenko, V.; Egli, S.; Eichler, R.; Eisele, F.; Eliseev, A.; Elsen, E.; Essenov, S.; Falkiewicz, A.; Faulkner, P.J.W.; Favart, L.; Fedotov, A.; Felst, R.; Feltesse, J.; Ferencei, J.; Finke, L.; Fleischer, M.; Fomenko, A.; Franke, G.; Frisson, T.; Gabathuler, E.; Gayler, J.; Ghazaryan, S.; Glazov, A.; Glushkov, I.; Goerlich, L.; Goettlich, M.; Gogitidze, N.; Gorbounov, S.; Gouzevitch, M.; Grab, C.; Greenshaw, T.; Grell, B.R.; Grindhammer, G.; Habib, S.; Haidt, D.; Hansson, M.; Heinzelmann, G.; Helebrant, C.; Henderson, R.C.W.; Henschel, H.; Herrera, G.; Hildebrandt, M.; Hiller, K.H.; Hoffmann, D.; Horisberger, R.; Hovhannisyan, A.; Hreus, T.; Jacquet, M.; Janssen, M.E.; Janssen, X.; Jemanov, V.; Jonsson, L.; Johnson, D.P.; Jung, Andreas Werner; Jung, H.; Kapichine, M.; Katzy, J.; Kenyon, I.R.; Kiesling, C.; Klein, M.; Kleinwort, C.; Klimkovich, T.; Kluge, T.; Knutsson, A.; Kogler, R.; Korbel, V.; Kostka, P.; Kraemer, M.; Krastev, K.; Kretzschmar, J.; Kropivnitskaya, A.; Kruger, K.; Kutak, K.; Landon, M.P.J.; Lange, W.; Lastovicka-Medin, G.; Laycock, P.; Lebedev, A.; Leibenguth, G.; Lendermann, V.; Levonian, S.; Li, G.; Lindfeld, L.; Lipka, K.; Liptaj, A.; List, B.; List, J.; Loktionova, N.; Lopez-Fernandez, R.; Lubimov, V.; Lucaci-Timoce, A.I.; Lytkin, L.; Makankine, A.; Malinovski, E.; Marage, P.; Marti, Ll.; Martyn, H.U.; Maxfield, S.J.; Mehta, A.; Meier, K.; Meyer, A.B.; Meyer, H.; Meyer, H.; Meyer, J.; Michels, V.; Mikocki, S.; Milcewicz-Mika, I.; Mohamed, A.; Moreau, F.; Morozov, A.; Morris, J.V.; Mozer, M.U.; Mudrinic, M.; Muller, K.; Murin, P.; Nankov, K.; Naroska, B.; Naumann, Th.; Newman, P.R.; Niebuhr, C.; Nikiforov, A.; Nowak, G.; Nowak, K.; Nozicka, M.; Olivier, B.; Olsson, J.E.; Osman, S.; Ozerov, D.; Palichik, V.; Panagoulias, I.; Pandurovic, M.; Papadopoulou, Th.; Pascaud, C.; Patel, G.D.; Peng, H.; Perez, E.; Perez-Astudillo, D.; Perieanu, A.; Petrukhin, A.; Picuric, I.; Piec, S.; Pitzl, D.; Placakyte, R.; Polifka, R.; Povh, B.; Preda, T.; Prideaux, P.; Radescu, V.; Rahmat, A.J.; Raicevic, N.; Raspiareza, A.; Ravdandorj, T.; Reimer, P.; Risler, C.; Rizvi, E.; Robmann, P.; Roland, B.; Roosen, R.; Rostovtsev, A.; Rurikova, Z.; Rusakov, S.; Salek, D.; Salvaire, F.; Sankey, D.P.C.; Sauter, M.; Sauvan, E.; Schmidt, S.; Schmitt, S.; Schmitz, C.; Schoeffel, L.; Schoning, A.; Schultz-Coulon, H.C.; Sefkow, F.; Shaw-West, R.N.; Sheviakov, I.; Shtarkov, L.N.; Sloan, T.; Smiljanic, Ivan; Smirnov, P.; Soloviev, Y.; South, D.; Spaskov, V.; Specka, A.; Staykova, Z.; Steder, M.; Stella, B.; Stiewe, J.; Straumann, U.; Sunar, D.; Sykora, T.; Tchoulakov, V.; Thompson, G.; Thompson, P.D.; Toll, T.; Tomasz, F.; Tran, T.H.; Traynor, D.; Trinh, T.N.; Truol, P.; Tsakov, I.; Tseepeldorj, B.; Tsurin, I.; Turnau, J.; Tzamariudaki, E.; Urban, K.; Valkarova, A.; Vallee, C.; Van Mechelen, P.; Vargas Trevino, A.; Vazdik, Y.; Vinokurova, S.; Volchinski, V.; Weber, G.; Weber, R.; Wegener, D.; Werner, C.; Wessels, M.; Wissing, Ch.; Wolf, R.; Wunsch, E.; Yeganov, V.; Zacek, J.; Zalesak, J.; Zhang, Z.; Zhelezov, A.; Zhokin, A.; Zhu, Y.C.; Zimmermann, T.; Zohrabyan, H.; Zomer, F.

    2008-01-01

    A measurement of elastic deeply virtual Compton scattering gamma* p -> gamma p using e-p collision data recorded with the H1 detector at HERA is presented. The analysed data sample corresponds to an integrated luminosity of 145 pb^-1. The cross section is measured as a function of the virtuality Q^2 of the exchanged photon and the centre-of-mass energy W of the gamma*p system in the kinematic domain 6.5 < Q^2 < 80 GeV^2, 30 < W < 140 GeV and |t| < 1 GeV^2, where t denotes the squared momentum transfer at the proton vertex. The cross section is determined differentially in t for different Q^2 and W values and exponential t-slope parameters are derived. The measurements are compared to a NLO QCD calculation based on generalised parton distributions. In the context of the dipole approach, the geometric scaling property of the DVCS cross section is studied for different values of t.

  3. X-ray generation by inverse Compton scattering at the superconducting RF test facility

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Hirotaka, E-mail: hirotaka@post.kek.jp [KEK, 1-1 Oho, Tsukuba 305-0801, Ibaraki (Japan); Akemoto, Mitsuo; Arai, Yasuo; Araki, Sakae; Aryshev, Alexander; Fukuda, Masafumi; Fukuda, Shigeki; Haba, Junji; Hara, Kazufumi; Hayano, Hitoshi; Higashi, Yasuo; Honda, Yosuke; Honma, Teruya; Kako, Eiji; Kojima, Yuji; Kondo, Yoshinari; Lekomtsev, Konstantin; Matsumoto, Toshihiro; Michizono, Shinichiro; Miyoshi, Toshinobu [KEK, 1-1 Oho, Tsukuba 305-0801, Ibaraki (Japan); and others

    2015-02-01

    Quasi-monochromatic X-rays with high brightness have a broad range of applications in fields such as life sciences, bio-, medical applications, and microlithography. One method for generating such X-rays is via inverse Compton scattering (ICS). X-ray generation experiments using ICS were carried out at the superconducting RF test facility (STF) accelerator at KEK. A new beam line, newly developed four-mirror optical cavity system, and new X-ray detector system were prepared for experiments downstream section of the STF electron accelerator. Amplified pulsed photons were accumulated into a four-mirror optical cavity and collided with an incoming 40 MeV electron beam. The generated X-rays were detected using a microchannel plate (MCP) detector for X-ray yield measurements and a new silicon-on-insulator (SOI) detector system for energy measurements. The detected X-ray yield by the MCP detector was 1756.8±272.2 photons/(244 electron bunches). To extrapolate this result to 1 ms train length under 5 Hz operations, 4.60×10{sup 5} photons/1%-bandwidth were obtained. The peak X-ray energy, which was confirmed by the SOI detector, was 29 keV, and this is consistent with ICS X-rays.

  4. Measurement of deeply virtual Compton scattering and its t-dependence at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Aaron, F.D. [National Insitute for Physics and Nuclear Engineering (NIPNE), Bucharest (Romania)]|[Bucharest Univ. (Romania). Faculty of Physics; Aktas, A. [DESY Hamburg (Germany); Alexa, C. [National Insitute for Physics and Nuclear Engineering (NIPNE), Bucharest (RO)] (and others)

    2007-09-15

    A measurement of elastic deeply virtual Compton scattering {gamma}{sup *}p {yields} {gamma}p using e{sup -}p collision data recorded with the H1 detector at HERA is presented. The analysed data sample corresponds to an integrated luminosity of 145 pb{sup -1}. The cross section is measured as a function of the virtuality Q{sup 2} of the exchanged photon and the centre-of-mass energy W of the {gamma}{sup *}p system in the kinematic domain 6.5

  5. Narrow-band photon beam via laser Compton scattering in an energy recovery linac

    Directory of Open Access Journals (Sweden)

    T. Akagi

    2016-11-01

    Full Text Available Narrow-bandwidth photon beams in the x-ray and γ-ray energy ranges are expected to be applied in various fields. An energy recovery linac (ERL-based laser Compton scattering (LCS source employing a laser enhancement cavity can produce a high-flux and narrow-bandwidth photon beam. We conducted the first experiment of an ERL-based LCS source in combination with a laser enhancement cavity. We obtained LCS photons with an energy of 6.95±0.01  keV by colliding an electron beam of 20 MeV with a laser of 1064 nm wavelength. The photon flux at the interaction point was evaluated to be (2.6±0.1×10^{7}  photons/s with an average beam current of 58  μA and an average laser power of 10 kW. The energy bandwidth was evaluated to be 0.4% (rms with an opening angle of 0.14 mrad. The technologies demonstrated in this experiment are applicable for future ERL-based LCS sources.

  6. Deeply virtual Compton scattering off an unpolarised hydrogen target at HERMES

    Energy Technology Data Exchange (ETDEWEB)

    Burns, Jonathan R.T.

    2010-08-15

    Deeply Virtual Compton Scattering (DVCS) i.e. ep {yields} ep{gamma} is the simplest interaction that allows access to Generalised Parton Distributions (GPDs), a theoretical framework describing nucleon structure. The strong interest in GPDs results from the fact that they can be used to determine the total angular momentum of quarks inside the nucleon and provide a 3-dimensional picture of nucleon structure. The measurement of the DVCS process is facilitated by the interference with a competing interaction known as the Bethe-Heitler process which has the same nal state. DVCS information is obtained from the asymmetrical in distribution of the real photon around the azimuthal angle {phi} at HERMES. Beam charge and beam helicity asymmetries, extracted from DVCS events with an unpolarised hydrogen target recorded during the 2006-2007 and 1996-2007 data taking periods, are presented in this thesis. The asymmetry amplitudes are presented over the range of HERMES kinematic acceptance, with their dependence on kinematic variables t, x{sub B} and Q{sup 2} also shown and compared to a phenomenological model. (orig.)

  7. Technical Development of Profile Measurement for the Soft X-Ray Via Compton Backward Scattering

    CERN Document Server

    Saito, Taku; Hayano, Hitoshi; Hidume, Kentaro; Kashiwagi, Shigeru; Kuroda, Ryunosuke; Minamiguchi, Shuichi; Oshima, Akihiro; Ueyama, Daisuke; Urakawa, Junji; Washio, Masakazu

    2005-01-01

    A compact X-ray source is called for such various fields as material development, biological science, and medical treatment. At Waseda University, we have already succeeded to generate the soft X-ray of the wavelength within so-called water window region (250-500eV) via Compton backward scattering between 1047nm Nd:YLF laser and 4.2MeV high quality electron beam. Although this method equips some useful characters, e.g. high intensity, short pulse, energy variableness, etc, the X-ray generating system is compact enough to fit in tabletop size. In the next step, there rises two principal tasks, that is, to make the soft X-ray intensity higher, and to progress X-ray profile measurement techniques as preliminary experiments for biomicroscopy. Specifically, we utilize two-pass amp for the former, and irradiate X-ray to a resist film which is previously exposed by UV lamp or get images with X-ray CCD for the latter. In this conference, we will show the experimental results and some future plans.

  8. Single shot, double differential spectral measurements of inverse Compton scattering in the nonlinear regime

    Directory of Open Access Journals (Sweden)

    Y. Sakai

    2017-06-01

    Full Text Available Inverse Compton scattering (ICS is a unique mechanism for producing fast pulses—picosecond and below—of bright photons, ranging from x to γ rays. These nominally narrow spectral bandwidth electromagnetic radiation pulses are efficiently produced in the interaction between intense, well-focused electron and laser beams. The spectral characteristics of such sources are affected by many experimental parameters, with intense laser effects often dominant. A laser field capable of inducing relativistic oscillatory motion may give rise to harmonic generation and, importantly for the present work, nonlinear redshifting, both of which dilute the spectral brightness of the radiation. As the applications enabled by this source often depend sensitively on its spectra, it is critical to resolve the details of the wavelength and angular distribution obtained from ICS collisions. With this motivation, we present an experimental study that greatly improves on previous spectral measurement methods based on x-ray K-edge filters, by implementing a multilayer bent-crystal x-ray spectrometer. In tandem with a collimating slit, this method reveals a projection of the double differential angular-wavelength spectrum of the ICS radiation in a single shot. The measurements enabled by this diagnostic illustrate the combined off-axis and nonlinear-field-induced redshifting in the ICS emission process. The spectra obtained illustrate in detail the strength of the normalized laser vector potential, and provide a nondestructive measure of the temporal and spatial electron-laser beam overlap.

  9. Transverse Extension of Partons in the Proton probed by Deeply Virtual Compton Scattering

    CERN Document Server

    Akhunzyanov, R.; The COMPASS collaboration; Alexeev, G.D.; Amoroso, A.; Andrieux, V.; Anfimov, N.V.; Anosov, V.; Antoshkin, A.; Augsten, K.; Augustyniak, W.; Austregesilo, A.; Azevedo, C.D.R.; Badełek, B.; Balestra, F.; Ball, M.; Barth, J.; Beck, R.; Bedfer, Y.; Bernhard, J.; Bicker, K.; Bielert, E.R.; Birsa, R.; Bodlak, M.; Bordalo, P.; Bradamante, F.; Bressan, A.; Büchele, M.; Burtin, E.; Burtsev, V.E.; Chang, W.-C.; Chatterjee, C.; Chiosso, M.; Choi, I.; Chumakov, A.G.; Chung, S.-U.; Cicuttin, A.; Crespo, M.L.; Dalla Torre, S.; Dasgupta, S.S.; Dasgupta, S.; Denisov, O.Yu.; Dhara, L.; Donskov, S.V.; Doshita, N.; Dreisbach, Ch.; Dünnweber, W.; Dusaev, R.R.; Dziewiecki, M.; Efremov, A.; Eversheim, P.D.; Faessler, M.; Ferrero, A.; Finger, M.; jr., M.Finger; Fischer, H.; Franco, C.; du Fresne von Hohenesche, N.; Friedrich, J.M.; Frolov, V.; Fuchey, E.; Gautheron, F.; Gavrichtchouk, O.P.; Gerassimov, S.; Giarra, J.; Gnesi, I.; Gorzellik, M.; Grasso, A.; Gridin, A.; Grosse Perdekamp, M.; Grube, B.; Grussenmeyer, T.; Guskov, A.; Hahne, D.; Hamar, G.; von Harrach, D.; Heitz, R.; Herrmann, F.; Horikawa, N.; d'Hose, N.; Hsieh, C.-Y.; Huber, S.; Ishimoto, S.; Ivanov, A.; Ivanshin, Yu.; Iwata, T.; Jary, V.; Joosten, R.; Jörg, P.; Juraskova, K.; Kabuß, E.; Kerbizi, A.; Ketzer, B.; Khaustov, G.V.; Khokhlov, Yu.A.; Kisselev, Yu.; Klein, F.; Koivuniemi, J.H.; Kolosov, V.N.; Kondo, K.; Konorov, I.; Konstantinov, V.F.; Kotzinian, A.M.; Kouznetsov, O.M.; Kral, Z.; Krämer, M.; Krinner, F.; Kroumchtein, Z.V.; Kulinich, Y.; Kunne, F.; Kurek, K.; Kurjata, R.P.; Kuznetsov, I.I.; Kveton, A.; Lednev, A.A.; Levchenko, E.A.; Levillain, M.; Levorato, S.; Lian, Y.-S.; Lichtenstadt, J.; Longo, R.; Lyubovitskij, V.E.; Maggiora, A.; Magnon, A.; Makins, N.; Makke, N.; Mallot, G.K.; Mamon, S.A.; Marianski, B.; Martin, A.; Marzec, J.; Matoušek, J.; Matsuda, H.; Matsuda, T.; Meshcheryakov, G.V.; Meyer, M.; Meyer, W.; Mikhailov, Yu.V.; Mikhasenko, M.; Mitrofanov, E.; Mitrofanov, N.; Miyachi, Y.; Moretti, A.; Nagaytsev, A.; Nerling, F.; Neyret, D.; Nový, J.; Nowak, W.-D.; Nukazuka, G.; Nunes, A.S.; Olshevsky, A.G.; Orlov, I.; Ostrick, M.; Panzieri, D.; Parsamyan, B.; Paul, S.; Peng, J.-C.; Pereira, F.; Pešek, M.; Pešková, M.; Peshekhonov, D.V.; Pierre, N.; Platchkov, S.; Pochodzalla, J.; Polyakov, V.A.; Pretz, J.; Quaresma, M.; Quintans, C.; Ramos, S.; Regali, C.; Reicherz, G.; Riedl, C.; Rogacheva, N.S.; Ryabchikov, D.I.; Rybnikov, A.; Rychter, A.; Salac, R.; Samoylenko, V.D.; Sandacz, A.; Santos, C.; Sarkar, S.; Savin, I.A.; Sawada, T.; Sbrizzai, G.; Schiavon, P.; Schmieden, H.; Schönning, K.; Seder, E.; Selyunin, A.; Silva, L.; Sinha, L.; Sirtl, S.; Slunecka, M.; Smolik, J.; Srnka, A.; Steffen, D.; Stolarski, M.; Subrt, O.; Sulc, M.; Suzuki, H.; Szabelski, A.; Szameitat, T.; Sznajder, P.; Tasevsky, M.; Tessaro, S.; Tessarotto, F.; Thiel, A.; Tomsa, J.; Tosello, F.; Tskhay, V.; Uhl, S.; Vasilishin, B.I.; Vauth, A.; Veit, B.M.; Veloso, J.; Vidon, A.; Virius, M.; Wallner, S.; Wilfert, M.; ter Wolbeek, J.; Zaremba, K.; Zavada, P.; Zavertyaev, M.; Zemlyanichkina, E.; Zhuravlev, N.; Ziembicki, M.

    2018-01-01

    We report on the first measurement of exclusive single-photon muoproduction on the proton by COMPASS using 160 GeV/$c$ polarized $\\mu^+$ and $\\mu^-$ beams of the CERN SPS impinging on a liquid hydrogen target. We determine the dependence of the average of the measured $\\mu^+$ and $\\mu^-$ cross sections for deeply virtual Compton scattering on the squared four-momentum transfer $t$ from the initial to the final final proton. The slope $B$ of the $t$-dependence is fitted with a single exponential function, which yields $B=(4.3 \\ \\pm \\ 0.6_{\\text{stat}}\\ _{- \\ 0.3}^{+ \\ 0.1}\\big\\rvert_{\\text{sys}})\\,(\\text{GeV}/c)^{-2}$. This result can be converted into an average transverse extension of partons in the proton, $\\sqrt{\\langle r_{\\perp}^2 \\rangle} = (0.58 \\ \\pm \\ 0.04_{\\text{stat}}\\ _{- \\ 0.02}^{+ \\ 0.01}\\big\\rvert_{\\text{sys}}) \\text{fm}$. For this measurement, the average virtuality of the photon mediating the interaction is $\\langle Q^2 \\rangle = 1.8\\,(\\text{GeV/}c)^2$ and the average value of the Bjorken va...

  10. Study of the virtual Compton scattering in the deep inelastic range (DVCS) with the COMPASS installation

    International Nuclear Information System (INIS)

    Mosse, L.

    2002-02-01

    The experimental and theoretical aspects of the deep virtual Compton scattering (DVCS) are presented in the first chapter. The prevailing amplitude of DVCS is developed to lead to the introduction of the generalized distributions of partons. The second chapter is centered on the measurement campaigns performed throughout the world concerning DVCS processes and meson production. The experimental achieving of DVCS is difficult because it is an exclusive process that requires a perfect identification and moreover its cross-section is low. In the third chapter the author presents a feasibility study of a DVCS experiment using Compass installation in CERN, this experiment requires the designing of a recoil detector. By developing the theoretical studies presented in the first chapter, the author has computed an estimation of the expected counting rate. The main difficulty of this work is to be able to discriminate some events that lead to the same final state as DVCS. It is the case of the event characterized by the production of pions with very low impulse, the fourth chapter is dedicated to determination of the value of the cross-section of that event. A prototype of a recoil detector has been designed and tested and the first preliminary results are presented in the last chapter. (A.C.)

  11. Virtual deep Compton scattering from Hall A at Jefferson Laboratory; Diffusion Compton profondement virtuelle dans le Hall A au Jefferson Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Camacho, Carlos Munoz [Univ. Pierre et Marie Curie, Paris (France)

    2005-12-14

    Generalized Parton Distributions (GPDs), introduced in the late 90s, provide a universal description of hadrons in terms of the underlying degrees of freedom of Quantum Chromodynamics: quarks and gluons. GPDs appear in a wide variety of hard exclusive reactions and the advent of high luminosity accelerator facilities has made the study of GPDs accessible to experiment. Deeply Virtual Compton Scattering (DVCS) is the golden process involving GPDs. The first dedicated DVCS experiment ran in the Hall A of Jefferson Lab in Fall 2004. An electromagnetic calorimeter and a plastic scintillator detector were constructed for this experiment, together with specific electronics and acquisition system. The experiment preparation, data taking and analysis are described in this document. Results on the absolute cross section difference for opposite beam helicities provide the first measurement of a linear combination of GPDs as a function of the momentum transfer to the nucleon.

  12. Deeply virtual Compton scattering in the Hall A of Jefferson laboratory; Diffusion Compton profondement virtuelle dans le Hall A au Jefferson laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Munoz Camacho, C

    2005-12-15

    Generalized Parton Distributions (GPDs), introduced in the late 90's, provide a universal description of hadrons in terms of the underlying degrees of freedom of Quantum Chromodynamics: quarks and gluons. GPDs appear in a wide variety of hard exclusive reactions and the advent of high luminosity accelerator facilities has made the study of GPDs accessible to experiment. Deeply Virtual Compton Scattering (DVCS) is the golden process involving GPDs. The first dedicated DVCS experiment ran in the Hall A of Jefferson Lab in Fall 2004. An electromagnetic calorimeter and a plastic scintillator detector were constructed for this experiment, together with specific electronics and acquisition system. The experiment preparation, data taking and analysis are described in this document. Results on the absolute cross section difference for opposite beam helicities provide the first measurement of a linear combination of GPDs as a function of the momentum transfer to the nucleon. (author)

  13. Development and characterization of a tunable ultrafast X-ray source via inverse-Compton-scattering

    International Nuclear Information System (INIS)

    Jochmann, Axel

    2014-01-01

    will serve as a milestone and starting point for the scaling of the X-ray flux based on available interaction parameters of an ultrashort bright X-ray source at the ELBE center for high power radiation sources. The knowledge of the spatial and spectral distribution of photons from an inverse Compton scattering source is essential in designing future experiments as well as for tailoring the X-ray spectral properties to an experimental need.

  14. DESIGN OF A GAMMA-RAY SOURCE BASED ON INVERSE COMPTON SCATTERING AT THE FAST SUPERCONDUCTING LINAC

    Energy Technology Data Exchange (ETDEWEB)

    Mihalcea, D. [NICADD, DeKalb; Jacobson, B. [RadiaBeam Tech.; Murokh, A. [Fermilab; Piot, P. [Fermilab; Ruan, J. [Fermilab

    2016-10-10

    A watt-level average-power gamma-ray source is currently under development at the Fermilab Accelerator Science & Technology (FAST) facility. The source is based on the Inverse Compton Scattering of a high-brightness 300-MeV beam against a high-power laser beam circulating in an optical cavity. The back scattered gamma rays are expected to have photon energies up to 1.5 MeV. This paper discusses the optimization of the source, its performances, and the main challenges ahead.

  15. SPECT quantification: a review of the different correction methods with compton scatter, attenuation and spatial deterioration effects

    International Nuclear Information System (INIS)

    Groiselle, C.; Rocchisani, J.M.; Moretti, J.L.; Dreuille, O. de; Gaillard, J.F.; Bendriem, B.

    1997-01-01

    SPECT quantification: a review of the different correction methods with Compton scatter attenuation and spatial deterioration effects. The improvement of gamma-cameras, acquisition and reconstruction software opens new perspectives in term of image quantification in nuclear medicine. In order to meet the challenge, numerous works have been undertaken in recent years to correct for the different physical phenomena that prevent an exact estimation of the radioactivity distribution. The main phenomena that have to betaken into account are scatter, attenuation and resolution. In this work, authors present the physical basis of each issue, its consequences on quantification and the main methods proposed to correct them. (authors)

  16. Final state interaction and temperature effects in Compton scattering from lithium

    International Nuclear Information System (INIS)

    Sternemann, Christian

    2000-01-01

    This thesis presents measurements of lithium Compton profiles with an incident energy around 9 keV and a momentum space resolution of 0.02 a.u. to investigate the effect of final state interaction and thus to test the validity of the impulse approximation in interpreting the valence electron Compton profile. Furthermore, the temperature dependence of the lithium Compton profile is studied at 30 keV incident energy and 0.10 a.u. momentum space resolution. Both experiments are discussed with respect to the well known discrepancy between experimentally found lithium Compton profiles and results from bandstructure calculations in local density approximation. The valence Compton profiles measured at 9 keV show an asymmetric shape and the predicted sharp features at the Fermi break which should be resolved with the highly improved momentum space resolution are drastically smeared out. The asymmetry agrees well with calculations using a many-particle scheme including self-energy and vertex corrections of the proper polarization function. The additional broadening of the Compton profile is mainly attributed to the finite width of the spectral density function of the excited particle resulting in an intrinsic resolution limit for Compton profile measurements at low incident energies. Under these experimental conditions the application of the impulse approximation is not justified. The temperature dependent measurements of the lithium valence Compton profiles exhibit a narrowing of the valence electron Compton profile with increasing temperature. The Compton profile measured at 95 K is above the room temperature profile around the Fermi momentum and below at the Compton peak. No temperature dependence of the core electron contribution to the Compton profile is detected. The temperature effect is confronted with a temperature dependent jellium calculation and with computations utilizing an empirical local pseudopotential, where in the pseudopotential calculation the influence

  17. Evaluation of Position Resolution for a Prototype Whole-Body PET Detector Based on Suppressing Backgrounds by Compton Scattering

    Science.gov (United States)

    Fujihara, Kento; Emoto, Yusaku; Ito, Hiroshi; Kaneko, Naomi; Kaneko, Hideyuki; Kawai, Hideyuki; Kobayashi, Atsushi; Mizuno, Takahiro

    2018-01-01

    Existing PET (Positron Emission Tomography) systems make clear images in demonstration (measuring small PET reagent in pure water), however images in real diagnosis become unclear. The authors suspected that this problem was caused by Compton scattering in a detector. When PET systems observe plural photomultiplier tube outputs, an original emission point is regarded as centroid of the outputs. However, even if plural emission in Compton scattering occur, these systems calculate original point in the same way as single emission. Therefore, the authors considered that rejecting Compton scattering events makes PET systems much better, and made prototype counter. Main components of the prototype counter are plate-like high-growth-rate (HGR) La-GPS scintillators and wavelength shifting fibers (WLSF). HGR crystals grow 10 times as fast as a mono-crystal (a normal mono-crystal grows at 2 - 3 mm an hour). Thus, it includes microbubble and its transparency get worth. Consequently, HGR crystals usually are not used in radiation measuring instruments. However, this time they are used on the purpose. Because of their low transparency, scintillation lights come out right above and right under of emission position. Therefore, Compton scattering events is rejected easily. The prototype detector has an effective area of 300 by 300 square mm. The detector consists of 24 layers. One layer consists of HGR La-GPS scintillator of 1 mm thickness. Top and bottom surface of scintillator were covered by dual sheets of WLSF with a diameter of 0.2 mm. Sheets of WLSF on top and bottom of the scintillator make a right angle with each other, and measure X- and Y-components. Z-component is measured by difference of WLSF outputs between top and bottom. If plural layers output signals, this counter regards the event as Compton scattering event, and reject the event. Even if only a layer output signals, the event is rejected when number output signals from WLSF is more than 1.5 times of single

  18. Evaluation of Position Resolution for a Prototype Whole-Body PET Detector Based on Suppressing Backgrounds by Compton Scattering

    Directory of Open Access Journals (Sweden)

    FUJIHARA Kento

    2018-01-01

    Full Text Available Existing PET (Positron Emission Tomography systems make clear images in demonstration (measuring small PET reagent in pure water, however images in real diagnosis become unclear. The authors suspected that this problem was caused by Compton scattering in a detector. When PET systems observe plural photomultiplier tube outputs, an original emission point is regarded as centroid of the outputs. However, even if plural emission in Compton scattering occur, these systems calculate original point in the same way as single emission. Therefore, the authors considered that rejecting Compton scattering events makes PET systems much better, and made prototype counter. Main components of the prototype counter are plate-like high-growth-rate (HGR La-GPS scintillators and wavelength shifting fibers (WLSF. HGR crystals grow 10 times as fast as a mono-crystal (a normal mono-crystal grows at 2 – 3 mm an hour. Thus, it includes microbubble and its transparency get worth. Consequently, HGR crystals usually are not used in radiation measuring instruments. However, this time they are used on the purpose. Because of their low transparency, scintillation lights come out right above and right under of emission position. Therefore, Compton scattering events is rejected easily. The prototype detector has an effective area of 300 by 300 square mm. The detector consists of 24 layers. One layer consists of HGR La-GPS scintillator of 1 mm thickness. Top and bottom surface of scintillator were covered by dual sheets of WLSF with a diameter of 0.2 mm. Sheets of WLSF on top and bottom of the scintillator make a right angle with each other, and measure X- and Y-components. Z-component is measured by difference of WLSF outputs between top and bottom. If plural layers output signals, this counter regards the event as Compton scattering event, and reject the event. Even if only a layer output signals, the event is rejected when number output signals from WLSF is more than 1

  19. Compton-scattering from hydrogen, deuterium and complex nuclei at photonenergies of 3 and 5 Gev under very small scattering angles

    International Nuclear Information System (INIS)

    Kahl, T.

    1976-01-01

    Compton scattering on hydrogen, deuterium and heavy nuclei up to hold was studied at very small momentum transfer and at two energies. Measurements were carried out in the region 0.002LT= /t/ LT=0.06 (GeV/c)**2 at 5 GeV and in the region 0.001 LT=/t/LT=0.02 (GeV/c)**2 at 3 GeV. (orig.) [de

  20. Commissioning of the scatter component of a Compton camera consisting of a stack of Si strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Liprandi, S.; Marinsek, T.; Bortfeldt, J.; Lang, C.; Lutter, R.; Dedes, G.; Parodi, K.; Thirolf, P.G. [LMU Munich, Garching (Germany); Aldawood, S. [LMU Munich, Garching (Germany); King Saud University, Riyadh (Saudi Arabia); Maier, L.; Gernhaeuser, R. [TU Munich, Garching (Germany); Kolff, H. van der [LMU Munich, Garching (Germany); TU Delft (Netherlands); Castelhano, I. [LMU Munich, Garching (Germany); University of Lisbon, Lisbon (Portugal); Schaart, D.R. [TU Delft (Netherlands)

    2015-07-01

    At LMU Munich in Garching a Compton camera is presently being developed aiming at the range verification of proton (or ion) beams for hadron therapy via imaging of prompt γ rays from nuclear reactions in the tissue. The poster presentation focuses on the characterization of the scatter component of the Compton camera, consisting of a stack of six double-sided Si strip detectors (50 x 50 mm{sup 2}, 0.5 mm thick, 128 strips/side). The overall 1536 electronics channels are processed by a readout system based on the GASSIPLEX ASIC chip, feeding into a VME-based data acquisition system. The status of the offline and online characterization studies is presented.

  1. Measurement of double-spin asymmetries associated with deeply virtual Compton scattering on a transversely polarized hydrogen target

    Energy Technology Data Exchange (ETDEWEB)

    Airapetian, A. [Physikalisches Institut, Universitaet Giessen, 35392 Giessen (Germany); Randall Laboratory of Physics, University of Michigan, Ann Arbor, MI 48109-1040 (United States); Akopov, N. [Yerevan Physics Institute, 375036 Yerevan (Armenia); Akopov, Z. [DESY, 22603 Hamburg (Germany); Aschenauer, E.C. [DESY, 15738 Zeuthen (Germany); Augustyniak, W. [Andrzej Soltan Institute for Nuclear Studies, 00-689 Warsaw (Poland); Avakian, R.; Avetissian, A. [Yerevan Physics Institute, 375036 Yerevan (Armenia); Avetisyan, E. [DESY, 22603 Hamburg (Germany); Belostotski, S. [Petersburg Nuclear Physics Institute, Gatchina, Leningrad region 188300 (Russian Federation); Bianchi, N. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati, 00044 Frascati (Italy); Blok, H.P. [National Institute for Subatomic Physics (Nikhef), 1009 DB Amsterdam (Netherlands); Department of Physics and Astronomy, VU University, 1081 HV Amsterdam (Netherlands); Borissov, A. [DESY, 22603 Hamburg (Germany); Bowles, J. [SUPA, School of Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ (United Kingdom); Brodski, I. [Physikalisches Institut, Universitaet Giessen, 35392 Giessen (Germany); Bryzgalov, V. [Institute for High Energy Physics, Protvino, Moscow region 142281 (Russian Federation); Burns, J. [SUPA, School of Physics and Astronomy, University of Glasgow, Glasgow G12 8QQ (United Kingdom); Capiluppi, M. [Istituto Nazionale di Fisica Nucleare, Sezione di Ferrara and Dipartimento di Fisica, Universita di Ferrara, 44100 Ferrara (Italy); Capitani, G.P. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati, 00044 Frascati (Italy); Cisbani, E. [Istituto Nazionale di Fisica Nucleare, Sezione di Roma, gruppo Sanita and Istituto Superiore di Sanita, 00161 Rome (Italy); Ciullo, G. [Istituto Nazionale di Fisica Nucleare, Sezione di Ferrara and Dipartimento di Fisica, Universita di Ferrara, 44100 Ferrara (Italy)

    2011-10-05

    Double-spin asymmetries in exclusive electroproduction of real photons from a transversely polarized hydrogen target are measured with respect to the product of target polarization with beam helicity and beam charge, and with respect to the product of target polarization with beam helicity alone. The asymmetries arise from the deeply virtual Compton scattering process and its interference with the Bethe-Heitler process. They are related to the real part of the same combination of Compton form factors as that determining the previously published transverse target single-spin asymmetries through the imaginary part. The results for the double-spin asymmetries are found to be compatible with zero within the uncertainties of the measurement, and are not incompatible with the predictions of the only available GPD-based calculation.

  2. Low momentum transfer measurements of pion electroproduction and virtual Compton scattering at the Delta resonance

    Energy Technology Data Exchange (ETDEWEB)

    Blomberg, Adam [Temple Univ., Philadelphia, PA (United States)

    2016-12-01

    Non-spherical components of the nucleon wave function are measured through p(e,e'p)π0 experiment at the Δ+(1232) resonance for Q2 = 0.04, 0.09, and 0.13 (GeV=c)2 utilizing the Jefferson National Accelerator Facility (JLab) pulsed beam and Hall A spectrometers. The new data extend the measurements of the Coulomb quadrupole amplitude to the lowest momentum transfer ever reached. The results disagree with predictions of constituent quark models and are in reasonable agreement with dynamical calculations that include pion cloud effects, chiral effective field theory and lattice calculations. The reported measurements indicate that improvement is required to the theoretical calculations and provide valuable input that will allow their refinements. The Coulomb to magnetic multipole ratio (CMR) and generalized polarizability (GP) of the nucleon are also measured through virtual Compton scattering (VCS) for Q2 = 0.2(GeV=c)2 utilizing the Mainz Microtron (MAMI) continuous beam and A1 spectrometers. This data represents the first low Q2 GP measurement at the Δ+(1232) resonance. The GP measurement explores a region where previous data and theoretical calculations disagree. The CMR measurement will be the first VCS extraction to compare with world data generated through pion electroproduction. The Dispersion Relation (DR) model used for the VCS extraction provides a new theoretical framework for the data signal and backgrounds that is largely independent from the pion electroproduction models. The independence of the DR from the traditional models provides a strong crosscheck on the ability of the models to isolate the data signal.

  3. Low momentum transfer measurements of pion electroproduction and virtual Compton scattering at the Delta resonance

    Science.gov (United States)

    Blomberg, Adam

    Non-spherical components of the nucleon wave function are measured through p(e,e' p)pi° experiment at the Delta+(1232) resonance for Q 2 = 0.04, 0.09, and 0.13 (GeV/c)2 utilizing the Jefferson National Accelerator Facility (JLab) pulsed beam and Hall A spectrometers. The new data extend the measurements of the Coulomb quadrupole amplitude to the lowest momentum transfer ever reached. The results disagree with predictions of constituent quark models and are in reasonable agreement with dynamical calculations that include pion cloud effects, chiral effective field theory and lattice calculations. The reported measurements indicate that improvement is required to the theoretical calculations and provide valuable input that will allow their refinements. The Coulomb to magnetic multipole ratio (CMR) and generalized polarizability (GP) of the nucleon are also measured through virtual Compton scattering (VCS) for Q2 = 0.2 (GeV/c) 2 utilizing the Mainz Microtron (MAMI) continuous beam and A1 spectrometers. This data represents the first low Q2 GP measurement at the Delta+(1232) resonance. The GP measurement explores a region where previous data and theoretical calculations disagree. The CMR measurement will be the first VCS extraction to compare with world data generated through pion electroproduction. The Dispersion Relation (DR) model used for the VCS extraction provides a new theoretical framework for the data signal and backgrounds that is largely independent from the pion electroproduction models. The independence of the DR from the traditional models provides a strong crosscheck on the ability of the models to isolate the data signal.

  4. Determination of electron beam parameters by means of laser-Compton scattering

    Directory of Open Access Journals (Sweden)

    K. Chouffani

    2006-05-01

    Full Text Available Laser-Compton scattering (LCS experiments were carried out at the Idaho Accelerator Center using the 5 ns (FWHM and 22 MeV electron beam. The electron beam was brought to an approximate head-on collision with a 29 MW, 7 ns (FWHM, 10 Hz Nd:YAG laser. Clear and narrow x-ray peaks resulting from the interaction of relativistic electrons with the Nd:YAG laser second harmonic line at 532 nm were observed. We have developed a relatively new method of using LCS as a nonintercepting electron beam monitor. Our method focused on the variation of the shape of the LCS spectrum rather than the LCS intensity as a function of the observation angle in order to extract the electron beam parameters at the interaction region. The electron beam parameters were determined by making simultaneous fits to spectra taken across the LCS x-ray cone. This scan method allowed us also to determine the variation of LCS x-ray peak energies and spectral widths as a function of the detector angles. Experimental data show that in addition to being viewed as a potential bright, tunable, and quasimonochromatic x-ray source, LCS can provide important information on the electron beam pulse length, direction, energy, angular and energy spread. Since the quality of LCS x-ray peaks, such as degree of monochromaticity, peak energy and flux, depends strongly on the electron beam parameters, LCS can therefore be viewed as an important nondestructive tool for electron beam diagnostics.

  5. GPU-accelerated iterative reconstruction from Compton scattered data using a matched pair of conic projector and backprojector.

    Science.gov (United States)

    Nguyen, Van-Giang; Lee, Soo-Jin

    2016-07-01

    Iterative reconstruction from Compton scattered data is known to be computationally more challenging than that from conventional line-projection based emission data in that the gamma rays that undergo Compton scattering are modeled as conic projections rather than line projections. In conventional tomographic reconstruction, to parallelize the projection and backprojection operations using the graphics processing unit (GPU), approximated methods that use an unmatched pair of ray-tracing forward projector and voxel-driven backprojector have been widely used. In this work, we propose a new GPU-accelerated method for Compton camera reconstruction which is more accurate by using exactly matched pair of projector and backprojector. To calculate conic forward projection, we first sample the cone surface into conic rays and accumulate the intersecting chord lengths of the conic rays passing through voxels using a fast ray-tracing method (RTM). For conic backprojection, to obtain the true adjoint of the conic forward projection, while retaining the computational efficiency of the GPU, we use a voxel-driven RTM which is essentially the same as the standard RTM used for the conic forward projector. Our simulation results show that, while the new method is about 3 times slower than the approximated method, it is still about 16 times faster than the CPU-based method without any loss of accuracy. The net conclusion is that our proposed method is guaranteed to retain the reconstruction accuracy regardless of the number of iterations by providing a perfectly matched projector-backprojector pair, which makes iterative reconstruction methods for Compton imaging faster and more accurate. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Longitudinal target-spin azimuthal asymmetry in Deeply-Virtual Compton Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Kopytin, M.

    2006-08-22

    As a generalization of the usual Parton Distribution Functions (PDFs) Generalized Parton Distributions (GPDs), introduced a decade ago, contain additional information about quark and gluon distributions in the plane transverse to the direction of motion of the nucleon. Strong interest in GPDs was triggered by the work of X. Ji who demonstrated that in the forward limit GPDs can give information about the total angular momentum carried by quarks (gluons) in the nucleon. The hard exclusive electroproduction of a real photon, called Deeply Virtual Compton Scattering (DVCS), appears to be the theoretically cleanest way to access GPDs experimentally. This process has a final state identical to that of the Bethe-Heitler (BH) process where the photon is radiated from either incoming or outgoing lepton. Both processes are experimentally indistinguishable as their amplitudes interfere. The interference term involves linearly the amplitudes of the DVCS process giving access to GPDs. In this thesis results from HERMES are reported on an azimuthal asymmetry with respect to the spin of the proton target, which is attributed to the interference between the Bethe-Heitler process and the DVCS process. The asymmetry, also referred to as the longitudinal target-spin asymmetry (LTSA), gives access mainly to the polarized GPD H. The kinematic dependences of the LTSA on t, x{sub B} and Q{sup 2} are measured and compared with the corresponding measurements on the deuteron. The results are compared with theoretical calculations and with the recent CLAS measurements. The data, used for analysis in this thesis, have been accumulated by the HERMES experiment at DESY scattering the HERA 27.6 GeV positron beam off hydrogen and deuterium gas targets. Additionally, production tests of the HELIX128 3.0 chip are discussed. The chip is the frontend readout chip of the silicon recoil detector. The latter is a part of the HERMES recoil detector, which is built around the target area in order to

  7. Longitudinal target-spin azimuthal asymmetry in Deeply-Virtual Compton Scattering

    International Nuclear Information System (INIS)

    Kopytin, M.

    2006-01-01

    As a generalization of the usual Parton Distribution Functions (PDFs) Generalized Parton Distributions (GPDs), introduced a decade ago, contain additional information about quark and gluon distributions in the plane transverse to the direction of motion of the nucleon. Strong interest in GPDs was triggered by the work of X. Ji who demonstrated that in the forward limit GPDs can give information about the total angular momentum carried by quarks (gluons) in the nucleon. The hard exclusive electroproduction of a real photon, called Deeply Virtual Compton Scattering (DVCS), appears to be the theoretically cleanest way to access GPDs experimentally. This process has a final state identical to that of the Bethe-Heitler (BH) process where the photon is radiated from either incoming or outgoing lepton. Both processes are experimentally indistinguishable as their amplitudes interfere. The interference term involves linearly the amplitudes of the DVCS process giving access to GPDs. In this thesis results from HERMES are reported on an azimuthal asymmetry with respect to the spin of the proton target, which is attributed to the interference between the Bethe-Heitler process and the DVCS process. The asymmetry, also referred to as the longitudinal target-spin asymmetry (LTSA), gives access mainly to the polarized GPD H. The kinematic dependences of the LTSA on t, x B and Q 2 are measured and compared with the corresponding measurements on the deuteron. The results are compared with theoretical calculations and with the recent CLAS measurements. The data, used for analysis in this thesis, have been accumulated by the HERMES experiment at DESY scattering the HERA 27.6 GeV positron beam off hydrogen and deuterium gas targets. Additionally, production tests of the HELIX128 3.0 chip are discussed. The chip is the frontend readout chip of the silicon recoil detector. The latter is a part of the HERMES recoil detector, which is built around the target area in order to detect the

  8. Charge dependence of the ratio of double to total ionization of a helium-like ion by Compton scattering of a high energy photon

    International Nuclear Information System (INIS)

    Suric, T.; Pisk, K.; Pratt, R.H.

    1996-01-01

    We examine the charge (Z) dependence of the nonrelativistic high energy limit for the double to total ionization ratio by Compton scattering of a photon, as well as by the photoeffect, utilizing our approach based on the impulse approximation or on the generalized shake-off theory. For all Z our high energy Compton ratio is about half the corresponding photoeffect ratio, calculated using the same assumptions or, alternatively, the ratio of double ionization by Compton scattering to double ionization by the photoeffect is about half the ratio for single ionization. We conclude that all current Compton calculations are consistent with this result, and we show that the recent calculation of Amusia and Mikhailov [Phys. Lett. A 199 (1995) 209] corresponds to our high Z results. (orig.)

  9. Verification of Compton scattering spectrum of a 662 keV photon beam scattered on a cylindrical steel target using MCNP5 code

    International Nuclear Information System (INIS)

    Thanh, Tran Thien; Nguyen, Vo Hoang; Chuong, Huynh Dinh; Tran, Le Bao; Tam, Hoang Duc; Binh, Nguyen Thi; Tao, Chau Van

    2015-01-01

    This article focuses on the possible application of a 137 Cs low-radioactive source (5 mCi) and a NaI(Tl) detector for measuring the saturation thickness of solid cylindrical steel targets. In order to increase the reliability of the obtained experimental results and to verify the detector response function of Compton scattering spectrum, simulation using Monte Carlo N-particle (MCNP5) code is performed. The obtained results are in good agreement with the response functions of the simulation scattering and experimental scattering spectra. On the basis of such spectra, the saturation depth of a steel cylinder is determined by experiment and simulation at about 27 mm using gamma energy of 662 keV ( 137 Cs) at a scattering angle of 120°. This study aims at measuring the diameter of solid cylindrical objects by gamma-scattering technique. - Highlights: • This study aims a possible application a 137 Cs low-radioactive source (5 mCi) and a NaI(Tl) detector for measuring the saturation thickness of solid cylindrical steel targets by gamma-scattering technique. • Monte Carlo N-particle (MCNP5) code is performed to verify on the detector response function of Compton scattering spectrum. • The results show a good agreement in response function of the experimental and simulation scattering spectra. • The saturation depth of a steel cylinder is determined by experiment and simulation at about 27 mm using gamma energy of 662 keV ( 137 Cs) at a scattering angle of 120°.

  10. The study of the magnetization process of fe film by magnetic Compton scattering and Mössbauer spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Agui, Akane, E-mail: agui@spring8.or.jp [Quantum Beam Science Center, Japan Atomic Energy Agency, SPring-8, Sayo, Hyogo 679-5148 (Japan); Masuda, Ryo; Kobayashi, Yasuhiro [Research Reactor Institute, Kyoto University, Sennan, Osaka 590-0494 (Japan); Kato, Tadashi; Emoto, Shun; Suzuki, Kosuke; Sakurai, Hiroshi [Department of Electronics and Informatics, Gunma University, Kiryu, Gunma 376-8515 (Japan)

    2016-06-15

    The magnetization process of Fe (110) film was investigated using the field dependence of magnetic Compton scattering and Mössbauer spectroscopy. The spin and orbital magnetic moment specific magnetization versus magnetizing field curves were obtained from the magnetic Compton profiles, and the angles between the magnetizing field and the magnetic moment, θ, were obtained from the Mössbauer spectra. It was found that the magnetizing field dependence of the ratio between orbital moment and spin moment was related to θ. We indicate that the magnetic field dependence of the orbital magnetic moment plays a role in the magnetization process. - Highlights: • We investigated the magnetization process of Fe film from microscopic view. • We measured the magnetic field dependence of Compton profile and Mössbauer spectra. • The spin and orbital magnetic moment specific magnetization curves were obtained. • The field dependence of angle of magnetic moment was obtained. • The orbital magnetic moment plays a role in the magnetization process of Fe.

  11. Nuclear-mass dependence of azimuthal beam-helicity and beam-charge asymmetries in deeply virtual Compton scattering

    Science.gov (United States)

    Airapetian, A.; Akopov, N.; Akopov, Z.; Amarian, M.; Aschenauer, E. C.; Augustyniak, W.; Avakian, R.; Avetissian, A.; Avetisyan, E.; Ball, B.; Belostotski, S.; Bianchi, N.; Blok, H. P.; Böttcher, H.; Borissov, A.; Bowles, J.; Bryzgalov, V.; Burns, J.; Capiluppi, M.; Capitani, G. P.; Cisbani, E.; Ciullo, G.; Contalbrigo, M.; Dalpiaz, P. F.; Deconinck, W.; Leo, R. De; Nardo, L. De; Sanctis, E. De; Diefenthaler, M.; Nezza, P. Di; Düren, M.; Ehrenfried, M.; Elbakian, G.; Ellinghaus, F.; Fabbri, R.; Fantoni, A.; Felawka, L.; Frullani, S.; Gabbert, D.; Gapienko, G.; Gapienko, V.; Garibaldi, F.; Gavrilov, G.; Gharibyan, V.; Giordano, F.; Gliske, S.; Guler, H.; Guzey, V.; Haan, S.; Hadjidakis, C.; Hartig, M.; Hasch, D.; Hill, G.; Hillenbrand, A.; Hoek, M.; Holler, Y.; Hristova, I.; Imazu, Y.; Ivanilov, A.; Jackson, H. E.; Jo, H. S.; Joosten, S.; Kaiser, R.; Karyan, G.; Keri, T.; Kinney, E.; Kisselev, A.; Korotkov, V.; Kozlov, V.; Kravchenko, P.; Lagamba, L.; Lamb, R.; Lapikás, L.; Lehmann, I.; Lenisa, P.; López Ruiz, A.; Lorenzon, W.; Lu, X.-G.; Lu, X.-R.; Ma, B.-Q.; Mahon, D.; Makins, N. C. R.; Manaenkov, S. I.; Manfré, L.; Mao, Y.; Marianski, B.; de La Ossa, A. Martinez; Marukyan, H.; Miller, C. A.; Miyachi, Y.; Movsisyan, A.; Muccifora, V.; Murray, M.; Mussgiller, A.; Nappi, E.; Naryshkin, Y.; Nass, A.; Negodaev, M.; Nowak, W.-D.; Pappalardo, L. L.; Perez-Benito, R.; Raithel, M.; Reimer, P. E.; Reolon, A. R.; Riedl, C.; Rith, K.; Rosner, G.; Rostomyan, A.; Rubin, J.; Ryckbosch, D.; Salomatin, Y.; Schäfer, A.; Schnell, G.; Schüler, K. P.; Shanidze, R.; Shibata, T.-A.; Shutov, V.; Stancari, M.; Statera, M.; Steffens, E.; Steijger, J. J. M.; Stewart, J.; Stinzing, F.; Taroian, S.; Terkulov, A.; Trzcinski, A.; Tytgat, M.; Vandenbroucke, A.; Haarlem, Y. Van; Hulse, C. Van; Varanda, M.; Veretennikov, D.; Vikhrov, V.; Vilardi, I.; Wang, S.; Yaschenko, S.; Ye, H.; Ye, Z.; Yu, W.; Zeiler, D.; Zihlmann, B.; Zupranski, P.; sHERMES Collaboration

    2010-03-01

    The nuclear-mass dependence of azimuthal cross-section asymmetries with respect to charge and longitudinal polarization of the lepton beam is studied for hard exclusive electroproduction of real photons. The observed beam-charge and beam-helicity asymmetries are attributed to the interference between the Bethe-Heitler and the deeply virtual Compton scattering processes. For various nuclei, the asymmetries are extracted for both coherent and incoherent-enriched regions, which involve different (combinations of) generalized parton distributions. For both regions, the asymmetries are compared to those for a free proton, and no nuclear-mass dependence is found.

  12. Nuclear-mass dependence of azimuthal beam-helicity and beam-charge asymmetries in deeply virtual Compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Airapetian, A. [Giessen Univ. (Germany). Physikalisches Inst.; Michigan Univ., Ann Arbor, MI (United States). Randall Lab. of Physics; Akopov, N. [Yerevan Physics Institute (Armenia); Akopov, Z. [DESY, Hamburg (DE)] (and others)

    2009-11-15

    The nuclear-mass dependence of azimuthal cross section asymmetries with respect to charge and longitudinal polarization of the lepton beam is studied for hard exclusive electroproduction of real photons. The observed beam-charge and beam-helicity asymmetries are attributed to the interference between the Bethe-Heitler and deeply virtual Compton scattering processes. For various nuclei, the asymmetries are extracted for both coherent and incoherent-enriched regions, which involve different (combinations of) generalized parton distributions. For both regions, the asymmetries are compared to those for a free proton, and no nuclear-mass dependence is found. (orig.)

  13. Development of a Watt-level gamma-ray source based on high-repetition-rate inverse Compton scattering

    Energy Technology Data Exchange (ETDEWEB)

    Mihalcea, D.; Murokh, A.; Piot, P.; Ruan, J.

    2017-07-01

    A high-brilliance (~1022 photon s-1 mm-2 mrad-2 /0.1%) gamma-ray source experiment is currently being planned at Fermilab (Eγ≃1.1 MeV). The source implements a high-repetition-rate inverse Compton scattering by colliding electron bunches formed in a ~300-MeV superconducting linac with a high-intensity laser pulse. This paper describes the design rationale along with some of technical challenges associated to producing high-repetition-rate collision. The expected performances of the gamma-ray source are also presented.

  14. Deeply Virtual Compton scattering at CERN. What is the size of the proton?

    Energy Technology Data Exchange (ETDEWEB)

    Joerg, Philipp

    2017-04-27

    Tremendous efforts have been made to understand the Englert-Brout-Higgs-Guralnik-Hagen-Kibble mechanism, which led to the successful discovery of the Higgs Boson and the clarification of the origin of the mass of fundamental particles. However, it is often forgotten that the vast majority of visible matter is given by baryons, which gain most of their mass dynamically within poorly known non-perturbative quantum chromodynamics processes. The best laboratory to study the underlying mechanisms of non-perturbative quantum chromodynamics is still given by the nucleon and the central question of how the macroscopic properties of a nucleon like its mass, spin and size can be comprehensively decomposed into the microscopic description in terms of quarks, antiquarks and gluons remains still open. A major part of the COMPASS-II program is dedicated to the investigation of Generalized Parton Distributions (GPDs), which aim for the most complete description of the partonic structure of the nucleon, comprising both, spacial and kinematic distributions. By including transverse degrees of freedom, a three dimensional picture of baryonic matter is created, which will revolutionise our understanding of what comprises 99 percent of the visible matter. GPDs are experimentally accessible via lepton-induced exclusive reactions, in particular the Deeply Virtual Compton Scattering (DVCS) and Deeply Virtual Meson Production (DVMP). At COMPASS, those processes are investigated using a high intensity muon beam of 160 GeV/c together with a 2.5 m-long liquid hydrogen target and an open field two stage spectrometer, to detect and identify charged and neutral particles. In order to optimize the selection of exclusive reactions at those energies, the target is surrounded by a new barrel-shaped time-of-flight system, which detects the recoiling target particles. A pilot run dedicated to the measurement of Generalized Parton distributions performed in 2012 allows for detailed performance studies

  15. Electronic structure of Ni2TiAl: Theoretical aspects and Compton scattering measurement

    Science.gov (United States)

    Sahariya, Jagrati; Ahuja, B. L.

    2012-11-01

    In this paper, we report electron momentum density of Ni2TiAl alloy using an in-house 20 Ci 137Cs (661.65 keV) Compton spectrometer. The experimental data have been analyzed in terms of energy bands and density of states computed using linear combination of atomic orbitals (LCAO) method. In the LCAO computations, we have considered local density approximation, generalized gradient approximation and recently developed second order generalized gradient approximation within the frame work of density functional theory. Anisotropies in theoretical Compton profiles along [1 0 0], [1 1 0] and [1 1 1] directions are also explained in terms of energy bands.

  16. Electronic structure of Ni{sub 2}TiAl: Theoretical aspects and Compton scattering measurement

    Energy Technology Data Exchange (ETDEWEB)

    Sahariya, Jagrati [Department of Physics, University College of Science, M.L. Sukhadia University, Durga Nursery Road, Udaipur 313001, Rajasthan (India); Ahuja, B.L., E-mail: blahuja@yahoo.com [Department of Physics, University College of Science, M.L. Sukhadia University, Durga Nursery Road, Udaipur 313001, Rajasthan (India)

    2012-11-01

    In this paper, we report electron momentum density of Ni{sub 2}TiAl alloy using an in-house 20 Ci {sup 137}Cs (661.65 keV) Compton spectrometer. The experimental data have been analyzed in terms of energy bands and density of states computed using linear combination of atomic orbitals (LCAO) method. In the LCAO computations, we have considered local density approximation, generalized gradient approximation and recently developed second order generalized gradient approximation within the frame work of density functional theory. Anisotropies in theoretical Compton profiles along [1 0 0], [1 1 0] and [1 1 1] directions are also explained in terms of energy bands.

  17. In operando quantitation of Li concentration for a commercial Li-ion rechargeable battery using high-energy X-ray Compton scattering.

    Science.gov (United States)

    Suzuki, Kosuke; Suzuki, Ayahito; Ishikawa, Taiki; Itou, Masayoshi; Yamashige, Hisao; Orikasa, Yuki; Uchimoto, Yoshiharu; Sakurai, Yoshiharu; Sakurai, Hiroshi

    2017-09-01

    Compton scattering is one of the most promising probes for quantitating Li under in operando conditions, since high-energy X-rays, which have high penetration power, are used as the incident beam and the Compton-scattered energy spectrum has specific line-shapes for each element. An in operando quantitation method to determine the Li composition in electrodes has been developed by using line-shape (S-parameter) analysis of the Compton-scattered energy spectrum. In this study, S-parameter analysis has been applied to a commercial coin cell Li-ion rechargeable battery and the variation of the S-parameters during the charge/discharge cycle at the positive and negative electrodes has been obtained. By using calibration curves for Li composition in the electrodes, the change in Li composition of the positive and negative electrodes has been determined using the S-parameters simultaneously.

  18. Compton scattering study and electronic properties of vanadium carbide: A validation of hybrid functional

    International Nuclear Information System (INIS)

    Joshi, Ritu; Sahariya, Jagrati; Ahuja, B.L.

    2011-01-01

    In this paper, we have reported the isotropic Compton profile of VC measured using high energy (661.65 keV) γ-radiations from a 137 Cs isotope. To compare the experimental momentum densities, we have also employed the linear combination of atomic orbitals (LCAO). In addition, energy bands, density of states and Fermi surface topology of VC have been computed using FP-LAPW and LCAO methods. It is seen that the LCAO with hybridization of density functional theory and Hartree-Fock (so called B3LYP) gives a better agreement with the present Compton profile experiment. This shows validation of an exact exchange part in hybrid density functional. On the basis of energy bands, we have discussed the microscopic origin for the anomalous behavior of hardness of VC. The relative nature of bonding in VC and NbC is also discussed in terms of valence charge densities and Mulliken's population analysis. To establish the role of Compton profiles in computation of cohesive properties of refractory materials, we have also calculated for the first time the cohesive energy using the present experimental Compton profile and compared it with the existing data.

  19. Compton scattering study and electronic properties of vanadium carbide: A validation of hybrid functional

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Ritu; Sahariya, Jagrati [Department of Physics, University College of Science, M.L. Sukhadia University, Udaipur 313001, Rajasthan (India); Ahuja, B.L., E-mail: blahuja@yahoo.co [Department of Physics, University College of Science, M.L. Sukhadia University, Udaipur 313001, Rajasthan (India)

    2011-05-01

    In this paper, we have reported the isotropic Compton profile of VC measured using high energy (661.65 keV) {gamma}-radiations from a {sup 137}Cs isotope. To compare the experimental momentum densities, we have also employed the linear combination of atomic orbitals (LCAO). In addition, energy bands, density of states and Fermi surface topology of VC have been computed using FP-LAPW and LCAO methods. It is seen that the LCAO with hybridization of density functional theory and Hartree-Fock (so called B3LYP) gives a better agreement with the present Compton profile experiment. This shows validation of an exact exchange part in hybrid density functional. On the basis of energy bands, we have discussed the microscopic origin for the anomalous behavior of hardness of VC. The relative nature of bonding in VC and NbC is also discussed in terms of valence charge densities and Mulliken's population analysis. To establish the role of Compton profiles in computation of cohesive properties of refractory materials, we have also calculated for the first time the cohesive energy using the present experimental Compton profile and compared it with the existing data.

  20. Chiral effective field theory with vector mesons. From the electromagnetic form factor until the virtual Compton scattering

    International Nuclear Information System (INIS)

    Gorini, Sandro

    2014-01-01

    This thesis is concerned with modelling electromagnetic and hadronic processes in the low-energy regime, employing a manifestly lorentz-invariant chiral effective field theory with dynamical vector mesons. This effective theory serves as an approximation of the more fundamental quantum chromodynamics at low energies. Focusing on power counting and renormalization, a consistent description of different processes up to approximately 1GeV is possible. The key ingredient of the power counting is a large-N c argument, which implies an equivalent treatment of Goldstone bosons (pions) and resonances (rho and omega mesons). A suitable renormalization scheme is the complex-mass scheme (a generalization of the extended on-mass-shell scheme) which - combined with the BPHZ renormalization method (named after Bogoliubov, Parasiuk, Hepp, and Zimmermann) - yields a powerful framework for the computation of quantum corrections in chiral effective theories. All calculations contain contributions up to and including fourth chiral order at the one-loop level. Analyzed quantities are, besides others, the vector form factor of the pion in the timelike region and real Compton scattering (respectively photon fusion) in the neutral and charged channels. In addition, virtual Compton scattering off the pion, embedded into electron-positron annihilation, is discussed. Furthermore, experimental data of various observables are used to extract the values of all contributing low-energy coupling constants. The developed methods - especially the technical implementations - are of very general nature and, therefore, straightforward to adapt to additional problems in low-energy quantum chromodynamics.

  1. Deeply virtual Compton scattering and its beam charge asymmetry in e{sup {+-}}p collisions at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Aaron, F.D. [National Institute for Physics and Nuclear Engineering (NIPNE), Bucharest (Romania); Bucharest Univ. (Romania). Faculty of Physics; Aldaya Martin, M. [DESY Hamburg (Germany); Alexa, C. [National Institute for Physics and Nuclear Engineering (NIPNE), Bucharest (RO)] (and others)

    2009-07-15

    A measurement of elastic deeply virtual Compton scattering {gamma}{sup *}p{yields}{gamma}p using e{sup +}p and e{sup -}p collision data recorded with the H1 detector at HERA is presented. The analysed data sample corresponds to an integrated luminosity of 306 pb{sup -1}, almost equally shared between both beam charges. The cross section is measured as a function of the virtuality Q{sup 2} of the exchanged photon and the centre-of-mass energy W of the {gamma}{sup *}p system in the kinematic domain 6.5 < Q{sup 2} < 80 GeV{sup 2}, 30Compton scattering processes. Experimental results are discussed in the context of two different models, one based on generalised parton distributions and one based on the dipole approach. (orig.)

  2. Deeply Virtual Compton Scattering and its Beam Charge Asymmetry in $e^{\\pm} p$ Collisions at HERA

    CERN Document Server

    Aaron, F.D.; Alexa, C.; Alimujiang, K.; Andreev, V.; Antunovic, B.; Backovic, S.; Baghdasaryan, A.; Barrelet, E.; Bartel, W.; Begzsuren, K.; Belousov, A.; Bizot, J.C.; Boudry, V.; Bozovic-Jelisavcic, I.; Bracinik, J.; Brandt, G.; Brinkmann, M.; Brisson, V.; Bruncko, D.; Bunyatyan, A.; Buschhorn, G.; Bystritskaya, L.; Campbell, A.J.; Cantun Avila, K.B.; Cerny, K.; Cerny, V.; Chekelian, V.; Cholewa, A.; Contreras, J.G.; Coughlan, J.A.; Cozzika, G.; Cvach, J.; Dainton, J.B.; Daum, K.; Deak, M.; de Boer, Y.; Delcourt, B.; Del Degan, M.; Delvax, J.; De Wolf, E.A.; Diaconu, C.; Dodonov, V.; Dossanov, A.; Dubak, A.; Eckerlin, G.; Efremenko, V.; Egli, S.; Eliseev, A.; Elsen, E.; Falkiewicz, A.; Favart, L.; Fedotov, A.; Felst, R.; Feltesse, J.; Ferencei, J.; Fischer, D.-J.; Fleischer, M.; Fomenko, A.; Gabathuler, E.; Gayler, J.; Ghazaryan, Samvel; Glazov, A.; Glushkov, I.; Goerlich, L.; Gogitidze, N.; Gouzevitch, M.; Grab, C.; Greenshaw, T.; Grell, B.R.; Grindhammer, G.; Habib, S.; Haidt, D.; Helebrant, C.; Henderson, R.C.W.; Hennekemper, E.; Henschel, H.; Herbst, M.; Herrera, G.; Hildebrandt, M.; Hiller, K.H.; Hoffmann, D.; Horisberger, R.; Hreus, T.; Jacquet, M.; Janssen, M.E.; Janssen, X.; Jonsson, L.; Jung, Andreas Werner; Jung, H.; Kapichine, M.; Katzy, J.; Kenyon, I.R.; Kiesling, C.; Klein, M.; Kleinwort, C.; Kluge, T.; Knutsson, A.; Kogler, R.; Kostka, P.; Kraemer, M.; Krastev, K.; Kretzschmar, J.; Kropivnitskaya, A.; Kruger, K.; Kutak, K.; Landon, M.P.J.; Lange, W.; Lastovicka-Medin, G.; Laycock, P.; Lebedev, A.; Leibenguth, G.; Lendermann, V.; Levonian, S.; Li, G.; Lipka, K.; Liptaj, A.; List, B.; List, J.; Loktionova, N.; Lopez-Fernandez, R.; Lubimov, V.; Makankine, A.; Malinovski, E.; Marage, P.; Marti, Ll.; Martyn, H.-U.; Maxfield, S.J.; Mehta, A.; Meyer, A.B.; Meyer, H.; Meyer, H.; Meyer, J.; Michels, V.; Mikocki, S.; Milcewicz-Mika, I.; Moreau, F.; Morozov, A.; Morris, J.V.; Mozer, Matthias Ulrich; Mudrinic, M.; Muller, K.; Murin, P.; Naumann, Th.; Newman, P.R.; Niebuhr, C.; Nikiforov, A.; Nikitin, D.; Nowak, G.; Nowak, K.; Nozicka, M.; Olivier, B.; Olsson, J.E.; Osman, S.; Ozerov, D.; Palichik, V.; Panagoulias, I.; Pandurovic, M.; Papadopoulou, Th.; Pascaud, C.; Patel, G.D.; Pejchal, O.; Perez, E.; Petrukhin, A.; Picuric, I.; Piec, S.; Pitzl, D.; Placakyte, R.; Pokorny, B.; Polifka, R.; Povh, B.; Radescu, V.; Rahmat, A.J.; Raicevic, N.; Raspiareza, A.; Ravdandorj, T.; Reimer, P.; Rizvi, E.; Robmann, P.; Roland, B.; Roosen, R.; Rostovtsev, A.; Rotaru, M.; Ruiz Tabasco, J.E.; Rurikova, Z.; Rusakov, S.; Salek, D.; Sankey, D.P.C.; Sauter, M.; Sauvan, E.; Schmitt, S.; Schoeffel, L.; Schoning, A.; Schultz-Coulon, H.-C.; Sefkow, F.; Shaw-West, R.N.; Shtarkov, L.N.; Shushkevich, S.; Sloan, T.; Smiljanic, Ivan; Soloviev, Y.; Sopicki, P.; South, D.; Spaskov, V.; Specka, Arnd E.; Staykova, Z.; Steder, M.; Stella, B.; Stoicea, G.; Straumann, U.; Sunar, D.; Sykora, T.; Tchoulakov, V.; Thompson, G.; Thompson, P.D.; Toll, T.; Tomasz, F.; Tran, T.H.; Traynor, D.; Trinh, T.N.; Truol, P.; Tsakov, I.; Tseepeldorj, B.; Turnau, J.; Urban, K.; Valkarova, A.; Vallee, C.; Van Mechelen, P.; Vargas Trevino, A.; Vazdik, Y.; Vinokurova, S.; Volchinski, V.; von den Driesch, M.; Wegener, D.; Wissing, Ch.; Wunsch, E.; Zacek, J.; Zalesak, J.; Zhang, Z.; Zhokin, A.; Zimmermann, T.; Zohrabyan, H.; Zomer, F.; Zus, R.

    2009-01-01

    A measurement of elastic deeply virtual Compton scattering gamma* p -> gamma p using e^+ p and e^- p collision data recorded with the H1 detector at HERA is presented. The analysed data sample corresponds to an integrated luminosity of 306 pb^-1, almost equally shared between both beam charges. The cross section is measured as a function of the virtuality Q^2 of the exchanged photon and the centre-of-mass energy W of the gamma* p system in the kinematic domain 6.5 < Q^2 < 80 GeV^2, 30 < W < 140 GeV and |t| < 1 GeV^2, where t denotes the squared momentum transfer at the proton vertex. The cross section is determined differentially in t for different Q^2 and W values and exponential t-slope parameters are derived. Using e^+ p and e^- p data samples, a beam charge asymmetry is extracted for the first time in the low Bjorken x kinematic domain. The observed asymmetry is attributed to the interference between Bethe-Heitler and deeply virtual Compton scattering processes. Experimental results are dis...

  3. Determination of the mass attenuation coefficients for X-ray fluorescence measurements correction by the Rayleigh to Compton scattering ratio

    Science.gov (United States)

    Conti, C. C.; Anjos, M. J.; Salgado, C. M.

    2014-09-01

    X-ray fluorescence technique plays an important role in nondestructive analysis nowadays. The development of equipment, including portable ones, enables a wide assortment of possibilities for analysis of stable elements, even in trace concentrations. Nevertheless, despite of the advantages, one important drawback is radiation self-attenuation in the sample being measured, which needs to be considered in the calculation for the proper determination of elemental concentration. The mass attenuation coefficient can be determined by transmission measurement, but, in this case, the sample must be in slab shape geometry and demands two different setups and measurements. The Rayleigh to Compton scattering ratio, determined from the X-ray fluorescence spectrum, provides a link to the mass attenuation coefficient by means of a polynomial type equation. This work presents a way to construct a Rayleigh to Compton scattering ratio versus mass attenuation coefficient curve by using the MCNP5 Monte Carlo computer code. The comparison between the calculated and literature values of the mass attenuation coefficient for some known samples showed to be within 15%. This calculation procedure is available on-line at www.macx.net.br.

  4. Thermal management and prototype testing of Compton scattering X-ray beam position monitor for the Advanced Photon Source Upgrade

    Science.gov (United States)

    Lee, S. H.; Yang, B. X.; Collins, J. T.; Ramanathan, M.

    2017-02-01

    Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source Upgrade. In the next-generation XBPMs for the canted-undulator front ends, where two undulator beams are separated by 1.0 mrad, the lower beam power (changes through the interface via thermal simulations, the thermal contact resistance (TCR) of TIMs at an interface between two solid materials under even contact pressure must be known. This paper addresses the TCR measurements of several TIMs, including gold, silver, pyrolytic graphite sheet, and 3D graphene foam. In addition, a prototype of a Compton-scattering XBPM with diamond blades was installed at APS Beamline 24-ID-A in May 2015 and has been tested. This paper presents the design of the Compton-scattering XBPM, and compares thermal simulation results obtained for the diamond blade of this XBPM by the finite element method with in situ empirical measurements obtained by using reliable infrared technology.

  5. Study of the proton structure by measurements of polarization transfers in real Compton scattering at J Lab

    International Nuclear Information System (INIS)

    Fanelli, C.; Salme, G.; Cisbani, E.; Hamilton, D.; Wojtsekhowski, B.

    2014-01-01

    A preliminary analysis of polarization-transfer data at large scattering angle (70 degrees), obtained in an experiment of real Compton scattering on proton, performed in Hall-C of Jefferson Lab, is presented. It is also discussed the relevance of this kind of experiments for shedding light on the non-perturbative structure of the proton, at low energy, and on the transition from the non-perturbative regime to the perturbative one, that occurs at high energy. Moreover, the possibility to extract Compton form factors and the Generalized Parton Distributions (GPD), one of the most promising theoretical tool to determine the total angular momentum contribution of quarks and gluons to nucleon spin, is emphasized. The preliminary results appear consistent with GPD's based and Regge predictions. This is not sufficient yet to exclude pQCD COZ (Chernyak-Oglobin-Zhitnistsky) model, but it is another preliminary indication that the handbag approach seems to be the dominant mechanism at the energy of the experiment

  6. A measurement of the Q{sup 2}, W and t dependences of deeply virtual Compton scattering at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Chekanov, S.; Derrick, M.; Magill, S. [Argonne National Lab., Argonne, IL (US)] (and others)

    2008-12-15

    Deeply virtual Compton scattering, {gamma}{sup *}p{yields}{gamma}p, has been measured in e{sup +}p collisions at HERA with the ZEUS detector using an integrated luminosity of 61.1 pb{sup -1}. Cross sections are presented as a function of the photon virtuality, Q{sup 2}, and photon-proton centre-of-mass energy, W, for a wide region of the phase space, Q{sup 2}>1.5 GeV{sup 2} and 40scattered proton is measured in the leading proton spectrometer, corresponding to an integrated luminosity of 31.3 pb{sup -1}, is used for the first direct measurement of the differential cross section as a function of t, where t is the square of the four-momentum transfer at the proton vertex. (orig.)

  7. Differential cross sections of proton Compton scattering at photon laboratory energies between 700 and 1000 MeV

    International Nuclear Information System (INIS)

    Jung, M.; Kattein, J.; Kueck, H.; Leu, P.; Marne, K.D. de; Wedemeyer, R.; Wermes, N.

    1981-05-01

    Differential cross sections of proton Compton scattering have been measured at the Bonn 2.5 GeV synchrotron. 78 data points are presented as angular distributions at photon lab energies of 700, 750, 800, 850, 900, and 950 MeV. The c.m. scattering angle ranges from 40 0 to 130 0 , corresponding to a variation of the four momentum transfer squared between t = -0.10 to t = -0.96 GeV 2 at 700 and 950 MeV, respectively. Two additional differential cross sections have been measured at 1000 MeV, 35.6 0 and 47.4 0 . The angular distributions show forward peaks whose extrapolations to 0 0 are consistent with calculated forward cross sections taken from literature. The small angle data ( vertical stroke t vertical stroke approx. 2 ) together with the calculated cross sections at 0 0 are also consistent with the assumption of a slope parameter B of 5 GeV -2 . For the first time a re-rise of the angular distributions towards backward angles has been observed. It becomes less steep with increasing energy. The most interesting feature of the angular distributions is a sharp structure which appears between t = -0.55 GeV 2 at 700 MeV and t = -0.72 GeV 2 at 950 MeV. Such a rapid variation of the differential cross section with t has never been observed in elastic hadron-hadron scattering or photoproduction processes. It indicates the existence of a dynamical mechanism which could be a peculiarity of Compton scattering. (orig.)

  8. Compton scatter in germanium and its effect on imaging with gamma-ray position-sensitive detectors

    International Nuclear Information System (INIS)

    Sherman, I.S.; Strauss, M.G.; Brenner, R.

    1978-01-01

    The spatial spread due to Compton scatter in Ge was measured to study the reduction in image contrast and signal-to-noise ratio (S/N) resulting from erroneous readout in Ge position-sensitive detectors. The step response revealing this spread was obtained by scanning with a 122 keV γ-ray beam across a boundary of two sectors of a slotted coaxial Ge(Li) detector that is 40 mm diameter by 22 mm long. The derived line-spread function at 140 keV (/sup 99m/Tc) exhibits much shorter but thicker tails than those due to scatter in tissue as observed with a NaI detector through 5.5 cm of scattering material. Convolutions of rectangular profiles of voids with the Ge(Li) line-spread function show marked deterioration in contrast for voids less than 10 mm across, which in turn results in even greater deterioration of the S/N. As a result, the contrast for voids in Ge images is only 20 to 30 percent higher than that in NaI and the S/N is only comparable for equal detector areas. The degradation in image contrast due to scatter in Ge detectors can be greatly reduced by either using thin detectors (approximately 5 mm), where scatter virtually does not exist, or by using thicker detectors and rejecting scatter electronically. To reduce the effects of scatter on the S/N as well as on contrast, the erroneous position readouts must actually be corrected. A more realizable approach to achieving the ultimate potential of Ge detectors may be a scanning array of discrete detectors (not position sensitive) in which readout is not affected by scatter

  9. High energy Compton scattering study of TiC and TiN

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Ritu; Bhamu, K.C.; Dashora, Alpa [Department of Physics, University College of Science, M.L. Sukhadia University, Udaipur 313001, Rajasthan (India); Ahuja, B.L., E-mail: blahuja@yahoo.co [Department of Physics, University College of Science, M.L. Sukhadia University, Udaipur 313001, Rajasthan (India)

    2011-05-15

    We present the experimental Compton profiles of TiC and TiN using 661.65 keV {gamma}-ray from 20 Ci {sup 137}Cs source. To explain our experimental data on momentum densities, we have computed the theoretical profiles, energy bands and density of states using linear combination of atomic orbitals scheme within the framework of density functional theory. In addition the energy bands, density of states and Fermi surfaces using full potential linearised augmented plane wave method have also been computed. Energy bands and density of states obtained from both the theoretical models show metallic character of TiC and TiN. The anisotropies in Compton line shapes and the Fermi surface topology are discussed in term of energy bands.

  10. Electronic properties of RDX and HMX: Compton scattering experiment and first-principles calculation.

    Science.gov (United States)

    Ahuja, B L; Jain, Pradeep; Sahariya, Jagrati; Heda, N L; Soni, Pramod

    2013-07-11

    The first-ever electron momentum density (EMD) measurements of explosive materials, namely, RDX (1,3,5-trinitro-1,3,5-triazacyclohexane, (CH2-N-NO2)3) and HMX (1,3,5,7-tetranitro-1,3,5,7-tetraazacyclooctane, (CH2-N-NO2)4), have been reported using a 740 GBq (137)Cs Compton spectrometer. Experimental Compton profiles (CPs) are compared with the EMDs derived from linear combination of atomic orbitals with density functional theory. It is found that the CPs deduced from generalized gradient approximation (GGA) with Wu-Cohen exchange energies give a better agreement with the corresponding experimental profiles than those from local density approximation and other schemes of GGA. Further, Mulliken population, energy bands, partial and total density of states, and band gap have also been reported using GGA calculations. Present ground state calculations unambiguously show large band gap semiconductor nature of both RDX and HMX. A similar type of bonding in these materials is uniquely established using Compton data and density of states. It is also outstandingly consistent with the Mulliken population, which predicts almost equal amount of charge transfer (0.84 and 0.83 e(-)) from H1 + H2 + N2 to C1 + N1 + O1 + O2 in both the explosives.

  11. A spectral geometric model for Compton single scatter in PET based on the single scatter simulation approximation

    DEFF Research Database (Denmark)

    Kazantsev, I.G.; Olsen, Ulrik Lund; Poulsen, Henning Friis

    2018-01-01

    scatter is interpreted as the volume integral over scatter points that constitute a rotation body with a football shape, while single scattering with a certain angle is evaluated as the surface integral over the boundary of the rotation body. The equations for total and sample single scatter calculations...... are derived using a single scatter simulation approximation. We show that the three-dimensional slice-by-slice filtered backprojection algorithm is applicable for scatter data inversion provided that the attenuation map is assumed to be constant. The results of the numerical experiments are presented....

  12. Analysis of Deeply Virtual Compton Scattering data at Jefferson Lab and proton tomography

    Energy Technology Data Exchange (ETDEWEB)

    Dupre, R.; Guidal, M.; Niccolai, S. [Institut de Physique Nucleaire d' Orsay, CNRS-IN2P3, Universite Paris-Sud, Universite Paris-Saclay, Orsay (France); Vanderhaeghen, M. [Johannes Gutenberg-Universitaet, Institut fuer Kernphysik und PRISMA Cluster of Excellence, Mainz (Germany)

    2017-08-15

    The CLAS and Hall A Collaborations at Jefferson Laboratory have recently released new results for the ep → epγ reaction. We analyze these new data within the Generalized Parton Distribution formalism. Employing a fitter algorithm introduced and used in earlier works, we are able to extract from these data new constraints on the kinematical dependence of three Compton Form Factors. Based on experimental data, we subsequently extract the dependence of the proton charge radius on the quarks' longitudinal momentum fraction. (orig.)

  13. Calculation of Characteristics of Radiation Generated with Compton Scattering Through Classical Electrodynamics Approach

    International Nuclear Information System (INIS)

    Drebot, I.; Grigor'ev, Y.; Zelinsky, A.

    2007-01-01

    Integration of Lorentz equation for a relativistic electron moving in the field of running, plane, linear polarized electromagnetic wave has been carried out. Using derived formulas for electron trajectories expressions for the radiation intensity spectrum were obtained. It is shown that for low intensity of the interacting electromagnetic wave the results of energy and angular spectrum calculations in the frame of classical electrodynamics completely coincide with calculation results produced using quantum electrodynamics. Simultaneously, derived expressions give possibilities to investigate dependence of energy and angular Compton radiation spectrum on phase of interaction and the interacting wave intensity

  14. Study of the relationship between peaks scattering Rayleigh to Compton ratio and effective atomic number in biological samples

    International Nuclear Information System (INIS)

    Pereira, Marcelo O.; Conti, Claudio de Carvalho; Anjos, Marcelino J.; Lopes, Ricardo T.

    2011-01-01

    The aim of this work was to develop a new method to correct the absorbed radiation (the mass attenuation coefficient curve) in low energy (E B O 3 , Na 2 CO 3 , CaCO 3 , Al 2 O 3 , K 2 SO 4 and MgO) of radiation produced by a gamma-ray source of Am-241(59.54 keV) also applied to certified biological samples of milk powder, hay powder and bovine liver (NIST 155 7B). In addition, six methods of effective atomic number determination were used as described in literature to determinate the Rayleigh to Compton scattering ratio (R/C) , in order to calculate the mass attenuation coefficient. The results obtained by the proposed method were compared with those obtained using the transmission method. The experimental results were in good agreement with transmission values suggesting that the method to correct radiation absorption presented in this paper is adequate for biological samples. (author)

  15. Soft X-ray generation via inverse compton scattering between high quality electron beam and high power laser

    International Nuclear Information System (INIS)

    Masakazu Washio; Kazuyuki Sakaue; Yoshimasa Hama; Yoshio Kamiya; Tomoko Gowa; Akihiko Masuda; Aki Murata; Ryo Moriyama; Shigeru Kashiwagi; Junji Urakawa

    2007-01-01

    High quality beam generation project based on High-Tech Research Center Project, which has been approved by Ministry of Education, Culture, Sports, Science and Technology in 1999, has been conducted by advance research institute for science and engineering, Waseda University. In the project, laser photo-cathode RF-gun has been selected for the high quality electron beam source. RF cavities with low dark current, which were made by diamond turning technique, have been successfully manufactured. The low emittance electron beam was realized by choosing the modified laser injection technique. The obtained normalized emmitance was about 3 m.mrad at 100 pC of electron charge. The soft x-ray beam generation with the energy of 370 eV, which is in the energy region of so-called water window, by inverse Compton scattering has been performed by the collision between IR laser and the low emmitance electron beams. (Author)

  16. Compton scattering study and electronic structure of different phases of NH4NO3

    International Nuclear Information System (INIS)

    Jain, Pradeep; Sahariya, Jagrati; Ahuja, B L

    2013-01-01

    In this paper, we present energy bands, density of states and the nature of hydrogen bonding in different temperature-dependent phases of NH 4 NO 3 , namely phases II (357–398 K), III (305–357 K) and IV (257–305 K), using the full potential linearized augmented plane wave and linear combination of atomic orbitals (LCAO) methods. Both band structure calculations show the insulating character of the II–IV phases of NH 4 NO 3 . In addition, we have reported the isotropic Compton profile of NH 4 NO 3 (IV) measured using 661.65 keV γ-radiation from a 137 Cs isotope. The experimental momentum density has been compared with that based on density functional theory (DFT) and Hartree–Fock schemes within the LCAO method. It is seen that the LCAO with hybridization of DFT and Hartree–Fock (so-called B3LYP) gives better agreement with the present Compton profile measurement. (paper)

  17. Compton scattering study and electronic structure of different phases of NH4NO3

    Science.gov (United States)

    Jain, Pradeep; Sahariya, Jagrati; Ahuja, B. L.

    2013-06-01

    In this paper, we present energy bands, density of states and the nature of hydrogen bonding in different temperature-dependent phases of NH4NO3, namely phases II (357-398 K), III (305-357 K) and IV (257-305 K), using the full potential linearized augmented plane wave and linear combination of atomic orbitals (LCAO) methods. Both band structure calculations show the insulating character of the II-IV phases of NH4NO3. In addition, we have reported the isotropic Compton profile of NH4NO3(IV) measured using 661.65 keV γ-radiation from a 137Cs isotope. The experimental momentum density has been compared with that based on density functional theory (DFT) and Hartree-Fock schemes within the LCAO method. It is seen that the LCAO with hybridization of DFT and Hartree-Fock (so-called B3LYP) gives better agreement with the present Compton profile measurement.

  18. Determination of the X-ray mass absorption coefficient by measurement of the intensity of AgKα Compton scattered radiation

    International Nuclear Information System (INIS)

    Franzini, M.; Leoni, L.; Saitta, M.

    1976-01-01

    By utilizing a reflection geometry, an accurate mass absorption coefficient of a sample can be determined by measuring the Ag Kα Compton intensity. Intensities of Ag Kα Compton scattered radiation have been collected by using either the usual reflection geometry of a Philips PW 1450 automatic x-ray spectrometer or a more refined reflection geometry, achieved on a Philips PW 1540/10A manual x-ray spectrometer. The experimental results have shown that the relationship between the Ag Kα Compton intensity and the mass absorption is a logarithmic function. The experimental results are not in agreement with those reported in literature, but a theoretical explanation to account for this fact has not been achieved as yet. (author)

  19. Compton scattering studies of the electron momentum distribution in indium phosphide

    CERN Document Server

    Deb, A; Guin, R; Chatterjee, A K

    1999-01-01

    The electron momentum anisotropy of indium phosphide has been studied by measuring the directional Compton profiles of indium phosphide single crystals with the use of radiation from an sup 2 sup 4 sup 1 Am gamma source. Three different samples, cut along the [100], [110] and [111] planes, were used. The experimental anisotropy has been compared with the results based on the linear combination of Gaussian orbitals (LCGO) method. The agreement is very good with our theoretical results. It is found that the extrema appearing in the dependences on q of the anisotropies have an intimate connection with the bonding properties of the semiconductor. A self-consistent, all-electron, local density calculation for the partial density of states, total density of states and the charge analysis is also presented here.

  20. Spin effects in nonlinear Compton scattering in a plane-wave laser pulse

    International Nuclear Information System (INIS)

    Boca, Madalina; Dinu, Victor; Florescu, Viorica

    2012-01-01

    We study theoretically the electron angular and energy distribution in the non-linear Compton effect in a finite plane-wave laser pulse. We first present analytical and numerical results for unpolarized electrons (described by a Volkov solution of the Dirac equation), in comparison with those corresponding to a spinless particle (obeying the Klein–Gordon equation). Then, in the spin 1/2 case, we include results for the spin flip probability. The regime in which the spin effects are negligible, i.e. the results for the unpolarized spin 1/2 particle coincide practically with those for the spinless particle, is the same as the regime in which the emitted radiation is well described by classical electrodynamics.

  1. Compton scattering study of ZrS1.5Se1.5

    International Nuclear Information System (INIS)

    Suthar, K.K.; Bhatt, Samir; Ahuja, B.L.; Jani, A.R.

    2015-01-01

    In this paper, we present the first ever experimental Compton profile (CP) of ZrS 1.5 Se 1.5 compound using 100 mCi 241 Am source. To analyze the experimental CP, theoretical profiles were derived using linear combination of atomic orbitals (LCAO) method within the Hartree-Fock (HF) scheme, density functional theory with generalized gradient approximation (DFT-GGA) and hybrid functional of HF and DFT (B3PW). It is seen that LCAO-DFT-GGA calculation gives a better agreement with the experimental data. Mulliken's population analysis shows the total transfer of 2.27 e - from Zr to S and Se atoms. (author)

  2. Two-colour X-gamma ray inverse Compton back-scattering source

    Science.gov (United States)

    Drebot, I.; Petrillo, V.; Serafini, L.

    2017-10-01

    We present a simple and new scheme for producing two-colour Thomson/Compton radiation with the possibility of controlling separately the polarization of the two different colours, based on the interaction of one single electron beam with two light pulses that can come from the same laser setup or from two different lasers and that collide with the electrons at different angle. One of the most interesting cases for medical applications is to provide two X-ray pulses across the iodine K-edge at 33.2 keV. The iodine is used as contrast medium in various imaging techniques and the availability of two spectral lines accross the K-edge allows one to produce subtraction images with a great increase in accuracy.

  3. Evaluation of errors due to Compton scattering in gamma-ray emission imaging

    International Nuclear Information System (INIS)

    Bruno, M.F.

    1983-12-01

    A set of computer simulation programs were developed to aid in the design of new instrumentation and in the design and evaluation of algorithms for scatter correction in positron emission computed tomography. 14 references, 15 figures, 3 tables

  4. Simulating measures of wood density through the surface by Compton scattering

    International Nuclear Information System (INIS)

    Penna, Rodrigo; Oliveira, Arno H.; Braga, Mario R.M.S.S.; Vasconcelos, Danilo C.; Carneiro, Clemente J.G.; Penna, Ariane G.C.

    2009-01-01

    Monte Carlo code (MCNP-4C) was used to simulate a nuclear densimeter for measuring wood densities nondestructively. An Americium source (E = 60 keV) and a NaI (Tl) detector were placed on a wood block surface. Results from MCNP shown that scattered photon fluxes may be used to determining wood densities. Linear regressions between scattered photons fluxes and wood density were calculated and shown correlation coefficients near unity. (author)

  5. Investigation of Compton scattering correction methods in cardiac SPECT by Monte Carlo simulations

    International Nuclear Information System (INIS)

    Silva, A.M. Marques da; Furlan, A.M.; Robilotta, C.C.

    2001-01-01

    The goal of this work was the use of Monte Carlo simulations to investigate the effects of two scattering correction methods: dual energy window (DEW) and dual photopeak window (DPW), in quantitative cardiac SPECT reconstruction. MCAT torso-cardiac phantom, with 99m Tc and non-uniform attenuation map was simulated. Two different photopeak windows were evaluated in DEW method: 15% and 20%. Two 10% wide subwindows centered symmetrically within the photopeak were used in DPW method. Iterative ML-EM reconstruction with modified projector-backprojector for attenuation correction was applied. Results indicated that the choice of the scattering and photopeak windows determines the correction accuracy. For the 15% window, fitted scatter fraction gives better results than k = 0.5. For the 20% window, DPW is the best method, but it requires parameters estimation using Monte Carlo simulations. (author)

  6. Neutron Compton scattering as a molecular characterization technique: A study on NaHF2

    International Nuclear Information System (INIS)

    Colognesi, D.; Pietropaolo, A.; Senesi, R.; Ramirez-Cuesta, A. J.

    2007-01-01

    Inelastic neutron scattering experiments were performed at intermediate and high momentum transfers, up to 85-90 A ring -1 , to study the proton momentum distribution in polycrystalline sodium hydrogen fluoride (NaHF 2 ) at low temperature (below 5 K). The H mean kinetic energy was extracted and compared to the results from hydrogen-projected density of phonon states derived from intermediate momentum transfer inelastic neutron scattering and lattice dynamics simulations. A reasonable agreement between the two figures was found. In addition, relevant aspects of high momentum transfer neutron scattering from NaHF 2 were explored in detail, ranging from an alternative evaluation of final state effects to the role played by the instrumental resolution and to the possibility to reconstruct the potential felt by a proton from its momentum distribution

  7. Inverse Compton scattering X-ray source yield optimization with a laser path folding system inserted in a pre-existent RF linac

    Energy Technology Data Exchange (ETDEWEB)

    Chaleil, A.; Le Flanchec, V.; Binet, A.; Nègre, J.P.; Devaux, J.F.; Jacob, V.; Millerioux, M.; Bayle, A.; Balleyguier, P. [CEA DAM DIF, F-91297 Arpajon (France); Prazeres, R. [CLIO/LCP, Bâtiment 201, Université Paris-Sud, F-91450 Orsay (France)

    2016-12-21

    An inverse Compton scattering source is under development at the ELSA linac of CEA, Bruyères-le-Châtel. Ultra-short X-ray pulses are produced by inverse Compton scattering of 30 ps-laser pulses by relativistic electron bunches. The source will be able to operate in single shot mode as well as in recurrent mode with 72.2 MHz pulse trains. Within this framework, an optical multipass system that multiplies the number of emitted X-ray photons in both regimes has been designed in 2014, then implemented and tested on ELSA facility in the course of 2015. The device is described from both geometrical and timing viewpoints. It is based on the idea of folding the laser optical path to pile-up laser pulses at the interaction point, thus increasing the interaction probability. The X-ray output gain measurements obtained using this system are presented and compared with calculated expectations.

  8. A Spectral Geometrical Model for Compton Scatter Tomography Based on the SSS Approximation

    DEFF Research Database (Denmark)

    Kazantsev, Ivan G.; Olsen, Ulrik Lund; Poulsen, Henning Friis

    2016-01-01

    The forward model of single scatter in the Positron Emission Tomography for a detector system possessing an excellent spectral resolution under idealized geometrical assumptions is investigated. This model has the form of integral equations describing a flux of photons emanating from the same ann...

  9. Spectral-ratio radon background correction method in airborne γ-ray spectrometry based on compton scattering deduction

    International Nuclear Information System (INIS)

    Gu Yi; Xiong Shengqing; Zhou Jianxin; Fan Zhengguo; Ge Liangquan

    2014-01-01

    γ-ray released by the radon daughter has severe impact on airborne γ-ray spectrometry. The spectral-ratio method is one of the best mathematical methods for radon background deduction in airborne γ-ray spectrometry. In this paper, an advanced spectral-ratio method was proposed which deducts Compton scattering ray by the fast Fourier transform rather than tripping ratios, the relationship between survey height and correction coefficient of the advanced spectral-ratio radon background correction method was studied, the advanced spectral-ratio radon background correction mathematic model was established, and the ground saturation model calibrating technology for correction coefficient was proposed. As for the advanced spectral-ratio radon background correction method, its applicability and correction efficiency are improved, and the application cost is saved. Furthermore, it can prevent the physical meaning lost and avoid the possible errors caused by matrix computation and mathematical fitting based on spectrum shape which is applied in traditional correction coefficient. (authors)

  10. Compton scattering by internal shields based on melanin-containing mushrooms provides protection of gastrointestinal tract from ionizing radiation.

    Science.gov (United States)

    Revskaya, Ekaterina; Chu, Peter; Howell, Robertha C; Schweitzer, Andrew D; Bryan, Ruth A; Harris, Matthew; Gerfen, Gary; Jiang, Zewei; Jandl, Thomas; Kim, Kami; Ting, Li-Min; Sellers, Rani S; Dadachova, Ekaterina; Casadevall, Arturo

    2012-11-01

    There is a need for radioprotectors that protect normal tissues from ionizing radiation in patients receiving high doses of radiation and during nuclear emergencies. We investigated the possibility of creating an efficient oral radioprotector based on the natural pigment melanin that would act as an internal shield and protect the tissues via Compton scattering followed by free radical scavenging. CD-1 mice were fed melanin-containing black edible mushrooms Auricularia auricila-judae before 9 Gy total body irradiation. The location of the mushrooms in the body before irradiation was determined by in vivo fluorescent imaging. Black mushrooms protected 80% of mice from the lethal dose, while control mice or those given melanin-devoid mushrooms died from gastrointestinal syndrome. The crypts of mice given black mushrooms showed less apoptosis and more cell division than those in control mice, and their white blood cell and platelet counts were restored at 45 days to preradiation levels. The role of melanin in radioprotection was proven by the fact that mice given white mushrooms supplemented with melanin survived at the same rate as mice given black mushrooms. The ability of melanin-containing mushrooms to provide remarkable protection against radiation suggests that they could be developed into oral radioprotectors.

  11. First observation of multi-pulse X-ray train via multi-collision laser Compton scattering

    International Nuclear Information System (INIS)

    Kuroda, R.; Toyokawa, H.; Yasumoto, M.; Ikeura-Sekiguchi, H.; Koike, M.; Yamada, K.; Yanagida, T.; Nakajyo, T.; Sakai, F.

    2009-01-01

    A compact hard X-ray source via laser Compton scattering (LCS) has been developed for biological and medical applications at the National Institute of Advanced Industrial Science and Technology (AIST) in Japan. The multi-collision LCS has been investigated in order to enhance the X-ray yields. The first observation of multi-pulse X-ray train with 6 pulses via the multi-collision LCS has been successfully demonstrated between the multi-bunch electron train with 6 bunches and the multi-pulse Ti:Sa laser train with 6 pulses. The 32 MeV electron train was generated from a Cs 2 Te photocathode rf gun with a multi-pulse UV laser and the S-band linac. The Ti:Sa laser train was obtained with the chirp pulse amplification (CPA) including the modified regenerative amplifier. The X-ray train with 6 pulses with 12.6 ns spacing was observed with the micro-channel plate (MCP). The maximum energy of the X-ray is analytically estimated to be about 24 keV and the total number of generated photons was calculated to be about 1.8x10 6 photons/train.

  12. A laser-Compton scattering prototype experiment at 100 MeV linac of Shanghai Institute of Applied Physics.

    Science.gov (United States)

    Luo, W; Xu, W; Pan, Q Y; Cai, X Z; Chen, J G; Chen, Y Z; Fan, G T; Fan, G W; Guo, W; Li, Y J; Liu, W H; Lin, G Q; Ma, Y G; Shen, W Q; Shi, X C; Xu, B J; Xu, J Q; Xu, Y; Zhang, H O; Yan, Z; Yang, L F; Zhao, M H

    2010-01-01

    As a prototype of the Shanghai Laser Electron Gamma Source in the Shanghai Synchrotron Radiation Facility, an x-ray source based on laser-Compton scattering (LCS) has been installed at the terminal of the 100 MeV linac of the Shanghai Institute of Applied Physics. LCS x-rays are generated by interactions between Q-switched Nd:yttrium aluminum garnet laser pulses [with wavelength of 1064 nm and pulse width of 21 ns (full width at half maximum)] and electron bunches [with energy of 108 MeV and pulse width of 0.95 ns (rms)] at an angle of 42 degrees between laser and electron beam. In order to measure the energy spectrum of LCS x-rays, a Si(Li) detector along the electron beam line axis is positioned at 9.8 m away from a LCS chamber. After background subtraction, the LCS x-ray spectrum with the peak energy of 29.1+/-4.4|(stat)+/-2.1|(syst) keV and the peak width (rms) of 7.8+/-2.8|(stat)+/-0.4|(syst) keV is observed. Normally the 100 MeV linac operates with the electron macropulse charge of 1.0 nC/pulse, and the electron and laser collision repetition rate of 20 Hz. Therefore, the total LCS x-ray flux of (5.2+/-2.0) x 10(2) Hz can be achieved.

  13. Photon-induced positron annihilation lifetime spectroscopy using ultrashort laser-Compton-scattered gamma-ray pulses.

    Science.gov (United States)

    Taira, Y; Toyokawa, H; Kuroda, R; Yamamoto, N; Adachi, M; Tanaka, S; Katoh, M

    2013-05-01

    High-energy ultrashort gamma-ray pulses can be generated via laser Compton scattering with 90° collisions at the UVSOR-II electron storage ring. As an applied study of ultrashort gamma-ray pulses, a new photon-induced positron annihilation lifetime spectroscopy approach has been developed. Ultrashort gamma-ray pulses with a maximum energy of 6.6 MeV and pulse width of 2.2 ps created positrons throughout bulk lead via pair production. Annihilation gamma rays were detected by a BaF2 scintillator mounted on a photomultiplier tube. A positron lifetime spectrum was obtained by measuring the time difference between the RF frequency of the electron storage ring and the detection time of the annihilation gamma rays. We calculated the response of the BaF2 scintillator and the time jitter caused by the variation in the total path length of the ultrashort gamma-ray pulses, annihilation gamma rays, and scintillation light using a Monte Carlo simulation code. The positron lifetime for bulk lead was successfully measured.

  14. Design of a Paraxial Inverse Compton Scattering Diagnostic for an Intense Relativistic Electron Beam

    Science.gov (United States)

    2013-06-01

    same energy range [26-29]. After the scattered photons are produced at z = 34.5 m they begin to propagate forward in a cone with a half angle of θs...34 Xray "Energy"(keV)" LIF" HOPG" PET" ADP" TAP" RAP" KAP" ODPB" Figure 7. Bragg angle plotted as a function crystal materials and X-ray energy. The

  15. Multiple compton scattering effect on the spectrum of X-ray radiation. Monte-Carlo computations

    International Nuclear Information System (INIS)

    Pozdnyakov, L.A.; Sobol', I.M.; Syunyaev, R.A.; AN SSSR, Moscow. Inst. Prikladnoj Matematiki)

    1977-01-01

    Computation of the X-ray radiation spectrum forming at multiple scattering of low-frequency photons on relativistic electrons is carried out. A spherical cloud of relativistic plasma with optical depth on Thomson scattering tau and a given temperature of Maxwellian electrons kTsub(e) is considered. There is a point source of low frequency radiation in the centre of the cloud with a Planckian spectrum. Monte-Carlo computations and analytical estimates show that in the case of small optical depth tau < 1, the radiation escaping from the cloud has a power-law spectrum Isub(ν) approximately νsup(-α) where α is the spectral index. In the case of an optically thick cloud, the escaping radiation spectrum tends to the Wien equilibrium shape. The energy loss rate of the cloud is computed. The transfer of hard radiation from a central point source through a plasma cloud with kTsub(e) approximately 3 keV is considered. Monte-Carlo techniques for computing such problems are decribed

  16. Fermi surface of a disordered Cu-Al -alloy single crystal studied by high-resolution Compton scattering and electron diffraction

    Science.gov (United States)

    Kwiatkowska, J.; Maniawski, F.; Matsumoto, I.; Kawata, H.; Shiotani, N.; Lityńska, L.; Kaprzyk, S.; Bansil, A.

    2004-08-01

    We have measured high resolution Compton scattering profiles for momentum transfer along a series of 28 independent directions from Cu0.842Al0.158 disordered alloy single crystals with normals to the surfaces oriented along the [100], [110], and [111] directions. The experimental spectra are interpreted via parallel first-principles KKR-CPA (Korringa-Kohn-Rostoker coherent-potential approximation) computations of these directional profiles. The Fermi surface determined by inverting the Compton data is found to be in good agreement with the KKR-CPA predictions. An electron diffraction study of the present Cu0.842Al0.158 sample is additionally undertaken to gain insight into short-range ordering effects. The scattering pattern displays not only the familiar diffuse scattering peaks, but also shows the presence of weak streaks interconnecting the four diffuse scattering spots around the (110) reciprocal lattice points. This study provides a comprehensive picture of the evolution of the shape of the Fermi surface of Cu with the addition of Al . Our results are consistent with the notion that Fermi surface nesting is an important factor in driving short-range ordering effects in disordered alloys.

  17. Can the cosmic x ray and gamma ray background be due to reflection of a steep power law spectrum and Compton scattering by relativistic electrons?

    Science.gov (United States)

    Zycki, Piotr T.; Zdziarski, Andrzej A.; Svensson, Roland

    1991-01-01

    We reconsider the recent model for the origin in the cosmic X-ray and gamma-ray background by Rogers and Field. The background in the model is due to an unresolved population of AGNs. An individual AGN spectrum contains three components: a power law with the energy index of alpha = 1.1, an enhanced reflection component, and a component from Compton scattering by relativistic electrons with a low energy cutoff at some minimum Lorentz factor, gamma(sub min) much greater than 1. The MeV bump seen in the gamma-ray background is then explained by inverse Compton emission by the electrons. We show that the model does not reproduce the shape of the observed X-ray and gamma-ray background below 10 MeV and that it overproduces the background at larger energies. Furthermore, we find the assumptions made for the Compton component to be physically inconsistent. Relaxing the inconsistent assumptions leads to model spectra even more different from that of the observed cosmic background. Thus, we can reject the hypothesis that the high-energy cosmic background is due to the described model.

  18. Study of Generalized Parton Distributions and Deeply Virtual Compton Scattering on the nucleon with the CLAS and CLAS12 detectors at the Jefferson Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Guegan, Baptiste [Rensselaer Polytechnic Inst., Troy, NY (United States)

    2012-11-01

    The exclusive leptoproduction of a real photon is considered to be the "cleanest" way to access the Generalized Parton Distribution (GPD). This process is called Deeply Virtual Compton Scattering (DVCS) lN {yields} lN{gamma} , and is sensitive to all the four GPDs. Measuring the DVCS cross section is one of the main goals of this thesis. In this thesis, we present the work performed to extract on a wide phase-space the DVCS cross-section from the JLab data at a beam energy of 6 GeV.

  19. Separation of contributions from deeply virtual Compton scattering and its interference with the Bethe-Heitler process in measurements on a hydrogen target

    International Nuclear Information System (INIS)

    Airapetian, A.; Akopov, Z.

    2009-09-01

    Hard exclusive leptoproduction of real photons from an unpolarized proton target is studied in an effort to elucidate generalized parton distributions. The data accumulated during the years 1996-2005 with the HERMES spectrometer are analyzed to yield asymmetries with respect to the combined dependence of the cross section on beam helicity and charge, thereby revealing previously unseparated contributions from deeply virtual Compton scattering and its interference with the Bethe-Heitler process. The integrated luminosity is sufficient to show correlated dependences on two kinematic variables, and provides the most precise determination of the dependence on only the beam charge. (orig.)

  20. Generation of energy-tunable and ultra-short-pulse gamma rays via inverse Compton scattering in an electron storage ring

    Science.gov (United States)

    Taira, Y.; Adachi, M.; Zen, H.; Tanikawa, T.; Yamamoto, N.; Hosaka, M.; Takashima, Y.; Soda, K.; Katoh, M.

    2011-10-01

    Inverse Compton-scattered gamma rays of tunable energy were generated by changing the collision angle between a laser and an electron beam of fixed energy at the electron storage ring, UVSOR-II. Analytic expressions were derived for energy and intensity of the gamma rays. The measured energy and intensity of the gamma rays agreed with the theoretical values, and the pulse width was calculated to be a few ps, under experimental conditions. It was shown that ultra-short gamma ray pulses with a pulse width of 150 fs can be generated by optimizing the size of the laser spot.

  1. Measurements of Polarization Transfers in Real Compton Scattering by a proton target at JLAB. A new source of information on the 3D shape of the nucleon

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Cristiano V. [Sapienza Univ. of Rome (Italy)

    2015-03-01

    In this thesis work, results of the analysis of the polarization transfers measured in real Compton scattering (RCS) by the Collaboration E07-002 at the Je fferson Lab Hall-C are presented. The data were collected at large scattering angle (theta_cm = 70deg) and with a polarized incident photon beam at an average energy of 3.8 GeV. Such a kind of experiments allows one to understand more deeply the reaction mechanism, that involves a real photon, by extracting both Compton form factors and Generalized Parton Distributions (GPDs) (also relevant for possibly shedding light on the total angular momentum of the nucleon). The obtained results for the longitudinal and transverse polarization transfers K_LL and K_LT, are of crucial importance, since they confirm unambiguously the disagreement between experimental data and pQCD prediction, as it was found in E99-114 experiment, and favor the Handbag mechanism. The E99-114 and E07-002 results can contribute to attract new interest on the great yield of the Compton scattering by a nucleon target, as demonstrated by the recent approval of an experimental proposal submitted to the Jefferson Lab PAC 42 for a Wide-angle Compton Scattering experiment, at 8 and 10 GeV Photon Energies. The new experiments approved to run with the updated 12 GeV electron beam at JLab, are characterized by much higher luminosities, and a new GEM tracker is under development to tackle the challenging backgrounds. Within this context, we present a new multistep tracking algorithm, based on (i) a Neural Network (NN) designed for a fast and efficient association of the hits measured by the GEM detector which allows the track identification, and (ii) the application of both a Kalman filter and Rauch-Tung-Striebel smoother to further improve the track reconstruction. The full procedure, i.e. NN and filtering, appears very promising, with high performances in terms of both association effciency and reconstruction accuracy, and these preliminary results will

  2. Compton profile of tantalum

    Indian Academy of Sciences (India)

    tion and Compton scattering (Omega Scientific Publishers, New Delhi, 1990) p. 261. [9] N I Papanicolaou, N C Bacalis and D A Papaconstantopoulos, Phys. Status Solidi B137, 597. (1986). [10] B K Sharma, B L Ahuja, H Singh and F M Mohammad, Pramana – J. Phys. 40, 339 (1993). Pramana – J. Phys., Vol. 60, No.

  3. Deeply virtual Compton scattering with the CLAS detector for the study of generalized parton distributions; Diffusion compton profondement virtuelle avec le detecteur CLAS pour une etude des distributions de partons generalisees

    Energy Technology Data Exchange (ETDEWEB)

    Girod, F.X

    2006-12-15

    The structure of the nucleon, among the first fundamental problems in hadronic physics, is the subject of a renewed interest. The lightest baryonic state has historically been described in two complementary approaches: through elastic scattering, measuring form factors which reflect the spatial shape of charge distributions, and through deep inelastic scattering, providing access to parton distribution functions which encode the momentum content carried by the constituents. The recently developed formalism of Generalized Parton Distributions unifies those approaches and provides access to new informations. The cleanest process sensitive to GPDs is the deeply virtual Compton scattering (DVCS) contributing to the ep {yields} ep{gamma} reaction. This work deals with a dedicated experiment accomplished with the CLAS detector, completed with two specific equipments: a lead tungstate calorimeter covering photon detection at small angles, and a superconducting solenoid actively shielding the electromagnetic background. The entire project is covered: from the upgrade of the experimental setup, through the update of the software, data taking and analysis, up to a first comparison of the beam spin asymmetry to model predictions. (author)

  4. An FPGA-based trigger processor for a measurement of deeply virtual Compton scattering at the COMPASS-II experiment

    Energy Technology Data Exchange (ETDEWEB)

    Schopferer, Sebastian

    2013-12-16

    The COMPASS-II experiment at CERN is focusing on a measurement of the deeply virtual Compton scattering. Several upgrades of the experimental setup have been performed in 2012, namely the construction of a long liquid hydrogen target and a surrounding recoil proton detector called CAMERA. Based on a time-of-flight measurement between two barrels of scintillators, the CAMERA detector allows to detect protons with a kinetic energy down to 35 MeV, which leave the target under large polar angles. At the same time, protons can be distinguished from other particles resulting from background processes by means of an energy loss measurement in the scintillating material. In order to extend the existing COMPASS trigger scheme, a digital trigger system has been developed, which is detailed in the thesis at hand. The trigger system is able to select events with a recoil proton in the final state while suppressing background events, using the particle identification capabilities of the CAMERA detector. Challenging selection criteria based on both the time-of-flight and the energy loss measurement call for a powerful programmable logic board. At the same time, the integration into the existing COMPASS trigger system poses strict constraints on the latency of the trigger decision. For the implementation of the proton trigger system, a new FPGA-based trigger and DAQ hardware called TIGER has been built. The module is operated in two firmware configurations, serving two distinct purposes. Firstly, the trigger processor is responsible for the generation of a trigger signal based on recoil particles, which is included in the global first-level trigger decision. Secondly, a readout concentrator allows to multiplex the data streams of up to 18 readout modules into one link to the DAQ. The CAMERA detector and the corresponding readout and trigger electronics was commissioned during a test run in autumn 2012. This thesis contains details about the trigger concept, the development of the

  5. Pion Virtual Compton Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Ocherashvili, Aharon [Tel Aviv U.

    2000-01-01

    Plasma production via field ionization occurs when an incoming electron beam is sufficiently dense that the electric field associated with the beam ionizes the neutral vapor. Experiments at the Stanford Linear Accelerator Center (SLAC) explore the threshold conditions necessary to induce field ionization in a neutral lithium (Li) vapor. By independently varying the bunch length, transverse spot size or number of electrons per bunch, the radial component of the electric field is controlled to be above or below the threshold for field ionization. A self-ionized plasma is an essential step for the viability of plasma-based accelerators for future high-energy experiments. Based on the experimental results, the incoming beam ionizes the neutral Li vapor when its peak electric field is approximately 5 G V / m and higher. This electric field translates into a peak charge density of approximately 3x 1016 cm-3 . The experimental conditions are approximated and simulated in a 2-D particle-in-cell code, OOPIC. The code and the data correspond well in terms of the correct threshold conditions and the dependence on the critical beam parameters. In addition to the ionization threshold, the field ionization effects are characterized by the beam's energy loss through the Li vapor column due to the plasma wake field production. The peak and average energy loss as a result of wake production and beam propagation through the plasma is compared with simulation results from OOPIC. The simulation code accurately predicts the peak energy loss of the beam, but approximations in the code produce differences between the average energy loss measured and the loss calculated by the simulation.

  6. Calculation of radiative corrections to virtual compton scattering - absolute measurement of the energy of Jefferson Lab. electron beam (hall A) by a magnetic method: arc project

    International Nuclear Information System (INIS)

    Marchand, D.

    1998-11-01

    This thesis presents the radiative corrections to the virtual compton scattering and the magnetic method adopted in the Hall A at Jefferson Laboratory, to measure the electrons beam energy with an accuracy of 10 4 . The virtual compton scattering experiments allow the access to the generalised polarizabilities of the protons. The extraction of these polarizabilities is obtained by the experimental and theoretical cross sections comparison. That's why the systematic errors and the radiative effects of the experiments have to be controlled very seriously. In this scope, a whole calculation of the internal radiative corrections has been realised in the framework of the quantum electrodynamic. The method of the dimensional regularisation has been used to the treatment of the ultraviolet and infra-red divergences. The absolute measure method of the energy, takes into account the magnetic deviation, made up of eight identical dipoles. The energy is determined from the deviation angle calculation of the beam and the measure of the magnetic field integral along the deviation

  7. Experimental setup for deeply virtual Compton scattering (DVCS) experiment in hall A at Jefferson Laboratory; Dispositif experimental pour la diffusion Compton virtuelle dans le regime profondement inelastique dans le hall A au Jefferson Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Camsonne, A

    2005-11-15

    The Hall A Deeply Virtual Compton Scattering (DVCS) experiment used the 5.757 GeV polarized electron beam available at Jefferson Laboratory and ran from september until december 2004. Using the standard Hall A left high resolution spectrometer three kinematical points were taken at a fixed x{sub b}(jorken) = 0.32 value for three Q{sup 2} values: 1.5 GeV{sup 2}, 1.91 GeV{sup 2}, 2.32 GeV{sup 2}. An electromagnetic Lead Fluoride calorimeter and a proton detector scintillator array designed to work at a luminosity of 10{sup 37} cm{sup -2}s{sup -1} were added to ensure the exclusivity of the DVCS reaction. In addition to the new detectors new custom electronics was used: a calorimeter trigger module which determines if an electron photon coincidence has occurred and a sampling system allowing to deal with pile-up events during the offline analysis. Finally the data from the kinematic at Q{sup 2} = 2.32 GeV{sup 2} and s = 5.6 GeV{sup 2} allowed to get a preliminary result for the exclusive {pi}{sup 0} electroproduction on the proton. (author)

  8. Study of the virtual Compton scattering in the deep inelastic range (DVCS) with the COMPASS installation; Etude de la diffusion compton virtuelle dans le regime profondement inelastique pour le dispositif experimental COMPASS

    Energy Technology Data Exchange (ETDEWEB)

    Mosse, L

    2002-02-01

    The experimental and theoretical aspects of the deep virtual Compton scattering (DVCS) are presented in the first chapter. The prevailing amplitude of DVCS is developed to lead to the introduction of the generalized distributions of partons. The second chapter is centered on the measurement campaigns performed throughout the world concerning DVCS processes and meson production. The experimental achieving of DVCS is difficult because it is an exclusive process that requires a perfect identification and moreover its cross-section is low. In the third chapter the author presents a feasibility study of a DVCS experiment using Compass installation in CERN, this experiment requires the designing of a recoil detector. By developing the theoretical studies presented in the first chapter, the author has computed an estimation of the expected counting rate. The main difficulty of this work is to be able to discriminate some events that lead to the same final state as DVCS. It is the case of the event characterized by the production of pions with very low impulse, the fourth chapter is dedicated to determination of the value of the cross-section of that event. A prototype of a recoil detector has been designed and tested and the first preliminary results are presented in the last chapter. (A.C.)

  9. Temperature dependent spin and orbital magnetization in TbCo{sub 2}: Magnetic Compton scattering and first-principles investigations

    Energy Technology Data Exchange (ETDEWEB)

    Ahuja, B.L., E-mail: blahuja@yahoo.com [Department of Physics, M.L. Sukhadia University, Udaipur 313001 (India); Mund, H.S. [Department of Physics, M.L. Sukhadia University, Udaipur 313001 (India); Sahariya, Jagrati [Department of Physics, Manipal University Jaipur, Jaipur 303007 (India); Dashora, Alpa [Department of Physics, University of Mumbai, Vidyanagri, Santacruz (E), Mumbai 400098 (India); Halder, Madhumita; Yusuf, S.M. [Solid State Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Itou, M.; Sakurai, Y. [Japan Synchrotron Radiation Research Institute, SPring8, 1-1-1 Kouto, Sayo, Hyogo 679-5198 (Japan)

    2015-06-05

    Highlights: • Presented temperature dependent spin momentum densities in TbCo{sub 2}. • Explored spin and orbital magnetic moments at different sites. • Contribution of local and itinerant moments in TbCo{sub 2} is explained. • First-principles calculations are performed to supplement the experiment. - Abstract: Spin-polarized Compton profiles of TbCo{sub 2} have been measured to elucidate the interesting behavior of spin and orbital moments at different temperatures. The magnetic Compton profiles (MCPs) have been analyzed in terms of site specific spin moments due to Tb-4f electrons, Co and itinerant electrons. The temperature dependence of the orbital moment has been deduced using Compton and magnetometry data ranging between 6 and 300 K. The present data exhibit a decrease in the ratio of orbital to spin moments from 43.9% to 35.0% (while going from 6 to 300 K). First-principles calculations within DFT + U scheme have also been performed to confirm the spin-, orbital- and site specific-magnetic moments in TbCo{sub 2}. An antiparallel exchange coupling between the Tb-4f and Co spin moments is found. The orbital moment is found to have a parallel coupling with the Tb spin moment, as evident from the experimental MCPs. From first-principles data it is seen that the orbital moments of Tb and Co sites are antiparallel to each other, as in the case of their spin magnetic moments. The present experimental study also shows an existence of an itinerant moment which is coupled ferromagnetically with the Tb-4f spin moment.

  10. Generation and application of soft-X-ray by means of inverse compton scattering between high quality election beam and IR laser

    International Nuclear Information System (INIS)

    Washio, M.; Sakaue, K.; Hama, Y.; Kamiya, Y.; Moriyama, R.; Hezume, K.; Saito, T.; Kuroda, R.; Kashiwagi, S.; Ushida, K.; Hayano, H.; Urakawa, J.

    2006-01-01

    High quality beam generation project based on High-Tech Research Center Project, which has been approved by Ministry of Education, Culture, Sports, Science and Technology in 1999, has been conducted by advance research institute for science and engineering, Waseda University. In the project, laser photo-cathode RF-gun has been selected for the high quality electron beam source. RF cavities with low dark current, which were made by diamond turning technique, have been successfully manufactured. The low emittance electron beam was realized by choosing the modified laser injection technique. The obtained normalized emittance was about 3 mm·mrad at 100 pC of electron charge. The soft X-ray beam generation with the energy of 370 eV, which is in the energy region of so-called 'water window', by inverse Compton scattering has been performed by the collision between IR laser and the low emittance electron beams. (authors)

  11. Nondestructive Inspection System for Special Nuclear Material Using Inertial Electrostatic Confinement Fusion Neutrons and Laser Compton Scattering Gamma-Rays

    Science.gov (United States)

    Ohgaki, H.; Daito, I.; Zen, H.; Kii, T.; Masuda, K.; Misawa, T.; Hajima, R.; Hayakawa, T.; Shizuma, T.; Kando, M.; Fujimoto, S.

    2017-07-01

    A Neutron/Gamma-ray combined inspection system for hidden special nuclear materials (SNMs) in cargo containers has been developed under a program of Japan Science and Technology Agency in Japan. This inspection system consists of an active neutron-detection system for fast screening and a laser Compton backscattering gamma-ray source in coupling with nuclear resonance fluorescence (NRF) method for precise inspection. The inertial electrostatic confinement fusion device has been adopted as a neutron source and two neutron-detection methods, delayed neutron noise analysis method and high-energy neutron-detection method, have been developed to realize the fast screening system. The prototype system has been constructed and tested in the Reactor Research Institute, Kyoto University. For the generation of the laser Compton backscattering gamma-ray beam, a race track microtron accelerator has been used to reduce the size of the system. For the NRF measurement, an array of LaBr3(Ce) scintillation detectors has been adopted to realize a low-cost detection system. The prototype of the gamma-ray system has been demonstrated in the Kansai Photon Science Institute, National Institutes for Quantum and Radiological Science and Technology. By using numerical simulations based on the data taken from these prototype systems and the inspection-flow, the system designed by this program can detect 1 kg of highly enriched 235U (HEU) hidden in an empty 20-ft container within several minutes.

  12. Single and double spin asymmetries for deeply virtual Compton scattering measured with CLAS and a longitudinally polarized proton target

    Energy Technology Data Exchange (ETDEWEB)

    Pisano, S.; Biselli, A.; Niccolai, S.; Seder, E.; Guidal, M.; Mirazita, M.; Adhikari, K. P.; Adikaram, D.; Amaryan, M. J.; Anderson, M. D.; Anefalos Pereira, S.; Avakian, H.; Ball, J.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Bosted, P.; Briscoe, B.; Brock, J.; Brooks, W. K.; Burkert, V. D.; Carlin, C.; Carman, D. S.; Celentano, A.; Chandavar, S.; Charles, G.; Colaneri, L.; Cole, P. L.; Compton, N.; Contalbrigo, M.; Cortes, O.; Crabb, D. G.; Crede, V.; D' Angelo, A.; De Vita, R.; De Sanctis, E.; Deur, A.; Djalali, C.; Dupre, R.; Egiyan, H.; El Alaoui, A.; El Fassi, L.; Elouadrhiri, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Fersch, R.; Filippi, A.; Fleming, J. A.; Fradi, A.; Garillon, B.; Garcon, M.; Ghandilyan, Y.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guo, L.; Hafidi, K.; Hanretty, C.; Hattawy, M.; Hicks, K.; Holtrop, M.; Hughes, S. M.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Jenkins, D.; Jiang, X.; Jo, H. S.; Joo, K.; Joosten, S.; Keith, C. D.; Keller, D.; Kim, A.; Kim, W.; Klein, F. J.; Kubarovsky, V.; Kuhn, S. E.; Lenisa, P.; Livingston, K.; Lu, H. Y.; MacCormick, M.; MacGregor, Ian J. D.; Mayer, M.; McKinnon, B.; Meekins, D. G.; Meyer, C. A.; Mokeev, V.; Montgomery, R. A.; Moody, C. I.; Munoz Camacho, C.; Nadel-Turonski, P.; Osipenko, M.; Ostrovidov, A. I.; Park, K.; Phelps, W.; Phillips, J. J.; Pogorelko, O.; Price, J. W.; Procureur, S.; Prok, Y.; Puckett, A. J. R.; Ripani, M.; Rizzo, A.; Rosner, G.; Rossi, P.; Roy, P.; Sabatie, F.; Salgado, C.; Schott, D.; Schumacher, R. A.; Skorodumina, I.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Sparveris, N.; Stepanyan, S.; Stoler, P.; Strauch, S.; Sytnik, V.; Tian, Ye; Tkachenko, S.; Turisini, M.; Ungaro, M.; Voutier, E.; Walford, N. K.; Watts, D. P.; Wei, X.; Weinstein, L. B.; Wood, M. H.; Zachariou, N.; Zana, L.; Zhang, J.; Zhao, Z. W.; Zonta, I.

    2015-03-19

    Single-beam, single-target, and double-spin asymmetries for hard exclusive photon production on the proton e→p→e'p'γ are presented. The data were taken at Jefferson Lab using the CLAS detector and a longitudinally polarized 14NH3 target. The three asymmetries were measured in 165 4-dimensional kinematic bins, covering the widest kinematic range ever explored simultaneously for beam and target-polarization observables in the valence quark region. The kinematic dependences of the obtained asymmetries are discussed and compared to the predictions of models of Generalized Parton Distributions. As a result, the measurement of three DVCS spin observables at the same kinematic points allows a quasi-model-independent extraction of the imaginary parts of the H and H~ Compton Form Factors, which give insight into the electric and axial charge distributions of valence quarks in the proton.

  13. A Comparison of Laser-induced Bremsstrahlung and Laser Compton Scattering for (γ, n) Photo-transmutation of Hazardous Nuclear Waste

    International Nuclear Information System (INIS)

    Rehman, Haseeb ur; Lee, Jiyoung; Kim, Yonghee

    2015-01-01

    This paper also presents sensitivity analysis to yield the maximum possible photo-transmutation rates. In general the possibility of radionuclide transmutation using photo-neutron reaction is evaluated in this work. In this paper a detailed methodology to calculate transmutation reaction rates using Laser Induced Bremsstrahlung (LIB) and Laser Compton Scattering (LCS) has been discussed. The methodology was validated by comparing the calculated reaction rates against published data in publically accessed literatures. In the second half of the paper, the authors present a novel concept to narrow down the LCS photon spectrum to an energy range that matches with the resonance region of a particular radionuclide. This is particularly useful considering hazardous waste is usually a mix of different isotopes. As such, being able to tune the LCS photon into any narrow energy range so as to selectively transmute any particular isotope of interest in the hazardous waste mixture would be very desirable. LCS spectrum is highly sensitive to the electron beam energy, laser power, laser luminosity and Compton backscattering angle. From the results it is quite evident that LCS is much better option for the radionuclide transmutation as reaction rates for the LCS is much higher than LIB method even for very small laser power. It can be seen even for the optimistic reaction rate calculations with Bremsstrahlung method reaction rate is much lower than LCS case for 10 Hz repetition rate. If repetition rate of laser 100 Hz then LIB reaction rate has the same order of the magnitude as the reaction rate via LCS. Higher Laser Powers can yield very high transmutation rates

  14. Inverse Compton Scattered Merger-nova: Late X-Ray Counterpart of Gravitational-wave Signals from NS–NS/BH Mergers

    Science.gov (United States)

    Ai, Shunke; Gao, He

    2018-01-01

    The recent observations of GW170817 and its electromagnetic (EM) counterparts show that double neutron star mergers could lead to rich and bright EM emissions. Recent numerical simulations suggest that neutron star and neutron star/black hole (NS–NS/BH) mergers would leave behind a central remnant surrounded by a mildly isotropic ejecta. The central remnant could launch a collimated jet and when the jet propagates through the ejecta, a mildly relativistic cocoon would be formed and the interaction between the cocoon and the ambient medium would accelerate electrons via external shock in a wide angle, so that the merger-nova photons (i.e., thermal emission from the ejecta) would be scattered into higher frequency via an inverse Compton (IC) process when they propagate through the cocoon shocked region. We find that the IC scattered component peaks at the X-ray band and it will reach its peak luminosity on the order of days (simultaneously with the merger-nova emission). With current X-ray detectors, such a late X-ray component could be detected out to 200 Mpc, depending on the merger remnant properties. It could serve as an important electromagnetic counterpart of gravitational-wave signals from NS–NS/BH mergers. Nevertheless, simultaneous detection of such a late X-ray signal and the merger-nova signal could shed light on the cocoon properties and the concrete structure of the jet.

  15. Differential cross sections of proton Compton scattering at photon laboratory energies between 1.2 and 1.7 GeV

    International Nuclear Information System (INIS)

    Duda, J.; Hoefner, F.W.; Jung, M.; Kleissler, R.; Kueck, H.; Leu, P.; Marne, K.D. de; Munk, B.; Vogl, W.; Wedemeyer, R.

    1982-11-01

    Differential cross sections of proton Compton scattering have been measured at the Bonn 2.5 GeV synchrotron. The experiment covers photon laboratory energies between 1.2 GeV and 1.7 GeV and the square of the four-momentum transfer ranges from t = -0.17 GeV 2 to -0.98 GeV 2 corresponding to c.m. scattering angles between 35 0 and 80 0 . The cross sections exhibit a forward peak followed by a monotone fall-off up to the largest measured vertical stroketvertical stroke-values. Fits of the form dsigma/dt = A.exp(Bt) to the data points with vertical stroketvertical stroke 2 yield forward cross sections A, which are consistent with the 0 0 cross sections calculated from the measured total photon-proton cross section. The average slope is B = 5.6 +- 0.14 GeV 2 . (orig.)

  16. First Exclusive Measurement of Deeply Virtual Compton Scattering off He4 : Toward the 3D Tomography of Nuclei

    Energy Technology Data Exchange (ETDEWEB)

    Hattawy, M.; Baltzell, N. A.; Dupré, R.; Hafidi, K.; Stepanyan, S.; Bültmann, S.; De Vita, R.; El Alaoui, A.; El Fassi, L.; Egiyan, H.; Girod, F. X.; Guidal, M.; Jenkins, D.; Liuti, S.; Perrin, Y.; Torayev, B.; Voutier, E.; Adhikari, K. P.; Adhikari, S.; Adikaram, D.; Akbar, Z.; Amaryan, M. J.; Anefalos Pereira, S.; Armstrong, Whitney R.; Avakian, H.; Ball, J.; Bashkanov, M.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Biselli, A. S.; Boiarinov, S.; Briscoe, W. J.; Brooks, W. K.; Burkert, V. D.; Thanh Cao, Frank; Carman, D. S.; Celentano, A.; Charles, G.; Chetry, T.; Ciullo, G.; Clark, L.; Colaneri, L.; Cole, P. L.; Contalbrigo, M.; Cortes, O.; Crede, V.; D’Angelo, A.; Dashyan, N.; De Sanctis, E.; Deur, A.; Djalali, C.; Elouadrhiri, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Fersch, R.; Filippi, A.; Fleming, J. A.; Forest, T. A.; Fradi, A.; Garçon, M.; Gevorgyan, N.; Ghandilyan, Y.; Gilfoyle, G. P.; Giovanetti, K. L.; Gleason, C.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guo, L.; Hakobyan, H.; Hanretty, C.; Harrison, N.; Heddle, D.; Hicks, K.; Holtrop, M.; Hughes, S. M.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jiang, H.; Joo, K.; Joosten, S.; Keller, D.; Khachatryan, G.; Khachatryan, M.; Khandaker, M.; Kim, A.; Kim, W.; Klein, A.; Klein, F. J.; Kubarovsky, V.; Kuhn, S. E.; Kuleshov, S. V.; Lanza, L.; Lenisa, P.; Livingston, K.; Lu, H. Y.; MacGregor, I. J. D.; Markov, N.; Mayer, M.; McCracken, M. E.; McKinnon, B.; Meyer, C. A.; Meziani, Z. E.; Mineeva, T.; Mirazita, M.; Mokeev, V.; Montgomery, R. A.; Moutarde, H.; Movsisyan, A.; Munoz Camacho, C.; Nadel-Turonski, P.; Net, L. A.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Paolone, M.; Paremuzyan, R.; Park, K.; Pasyuk, E.; Phelps, E.; Phelps, W.; Pisano, S.; Pogorelko, O.; Price, J. W.; Prok, Y.; Protopopescu, D.; Ripani, M.; Ritchie, B. G.; Rizzo, A.; Rosner, G.; Rossi, P.; Sabatié, F.; Salgado, C.; Schumacher, R. A.; Seder, E.; Sharabian, Y. G.; Simonyan, A.; Skorodumina, Iu.; Smith, G. D.; Sokhan, D.; Sparveris, N.; Strauch, S.; Taiuti, M.; Ungaro, M.; Voskanyan, H.; Walford, N. K.; Watts, D. P.; Wei, X.; Weinstein, L. B.; Wood, M. H.; Zachariou, N.; Zana, L.; Zhang, J.; Zhao, Z. W.

    2017-11-01

    We report on the first measurement of the beam-spin asymmetry in the exclusive process of coherent deeply virtual Compton scattering off a nucleus. The experiment uses the 6 GeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) accelerator at Jefferson Lab incident on a pressurized He-4 gaseous target placed in front of the CEBAF Large Acceptance Spectrometer (CLAS). The scattered electron is detected by CLAS and the photon by a dedicated electromagnetic calorimeter at forward angles. To ensure the exclusivity of the process, a specially designed radial time projection chamber is used to detect the recoiling He-4 nuclei. We measure beam-spin asymmetries larger than those observed on the free proton in the same kinematic domain. From these, we are able to extract, in a model-independent way, the real and imaginary parts of the only He-4 Compton form factor, HA. This first measurement of coherent deeply virtual Compton scattering on the He-4 nucleus, with a fully exclusive final state via nuclear recoil tagging, leads the way toward 3D imaging of the partonic structure of nuclei.

  17. Design of a polarized target made of pure HD: analysis and distillation of HD, resonant virtual Compton scattering on the nucleon at TJNAF

    International Nuclear Information System (INIS)

    Bouchigny, S.

    2004-04-01

    The first part describe my work on the frozen spin target project HYDILE. This target has to be made of very pure HD (Hydrogen Deuterium), better than 99.95%. However, commercial HD is never found with a concentration better than 98%. The goal was, then, to build an HD distillation facility which could produce pure HD. We describe, in this thesis, the design of the distillator and the implementation of a quadrupole mass spectrometer to monitor the HD purity during the distillation process. The second part of the thesis concerns the analysis taken at the electron accelerator facility TJNAF (Virginia, USA). We look at the electroproduction of Delta resonances involving Deep Virtual Compton Scattering (DeltaVCS). The interpretation of this reaction in terms of GPDs (Generalized Parton Distribution) can provide new insights to the nucleon structure. We focus on the measurement of the beam spin asymmetry which comes from the interference of the Bethe Heitler process with the DeltaVCS. (author)

  18. Compton scattering in jets: A mechanism for approximately 0.4 and less than or approximately 0.2 MeV line production

    Science.gov (United States)

    Skibo, J. G.; Dermer, C. D.; Ramaty, R.

    1994-01-01

    We show that gamma-ray line emission at approximately 0.4 and less than or approximately 0.2 MeV can be produced by Compton scattering of beamed radiation in the jets of Galactic black hole candidates. This mechanism has the novel feature of not invoking the presence of e(exp +)-e(exp -) pairs. To produce the two lines, we employ a symmetric double-sided jet with bulk flow velocity of about 0.5c and incident beam radiation with a hard energy spectrum. We show that the two lines can be seen at viewing-angle cosines relative to the jet ranging from 0.2 to 0.6. This comprises 40% of the total solid angle. In addition, the line radiation is approximately 10% polarized. Depending on the bulk flow and viewing angle, the model can produce lines at other energies as well. In particular, a broad feature near 1 MeV can be seen by viewing the jet close to its axis. Our model can also accommodate single-line spectra if the beamed gamma-ray emission or the jets themselves are asymmetric.

  19. Dual parametrization of the proton generalized parton distribution functions H and E, and description of the deeply virtual Compton scattering cross sections and asymmetries

    International Nuclear Information System (INIS)

    Guzey, V.; Teckentrup, T.

    2006-01-01

    We develop the minimal model of a new leading order parametrization of generalized parton distributions (GPDs) introduced by Polyakov and Shuvaev. The model for GPDs H and E is formulated in terms of the forward quark distributions, the Gegenbauer moments of the D-term, and the forward limit of the GPD E. The model is designed primarily for small and medium-size values of x B , x B ≤0.2. We examine two different models of the t dependence of the GPDs: the factorized exponential model and the nonfactorized Regge-motivated model. Using our model, we successfully described the deeply virtual Compton scattering (DVCS) cross section measured by H1 and ZEUS, the moments of the beam-spin A LU sinφ , the beam-charge A C cosφ , and the transversely polarized target A UT sinφcosφ DVCS asymmetries measured by HERMES and A LU sinφ measured by CLAS. The data on A C cosφ prefer the Regge-motivated model of the t dependence of the GPDs. The data on A UT sinφcosφ indicate that the u and d quarks carry only a small fraction of the proton total angular momentum

  20. Design and Mechanical Stability Analysis of the Interaction Region for the Inverse Compton Scattering Gamma-Ray Source Using Finite Element Method

    Science.gov (United States)

    Khizhanok, Andrei

    Development of a compact source of high-spectral brilliance and high impulse frequency gamma rays has been in scope of Fermi National Accelerator Laboratory for quite some time. Main goal of the project is to develop a setup to support gamma rays detection test and gamma ray spectroscopy. Potential applications include but not limited to nuclear astrophysics, nuclear medicine, oncology ('gamma knife'). Present work covers multiple interconnected stages of development of the interaction region to ensure high levels of structural strength and vibrational resistance. Inverse Compton scattering is a complex phenomenon, in which charged particle transfers a part of its energy to a photon. It requires extreme precision as the interaction point is estimated to be 20 microm. The slightest deflection of the mirrors will reduce effectiveness of conversion by orders of magnitude. For acceptable conversion efficiency laser cavity also must have >1000 finesse value, which requires a trade-off between size, mechanical stability, complexity, and price of the setup. This work focuses on advantages and weak points of different designs of interaction regions as well as in-depth description of analyses performed. This includes laser cavity amplification and finesse estimates, natural frequency mapping, harmonic analysis. Structural analysis is required as interaction must occur under high vacuum conditions.

  1. Methodology for obtaining a solution for the three-dimensional Boltzmann transport equation and an expression for the calculation of the total doses considering Compton scattering simulated by Klein-Nishina

    International Nuclear Information System (INIS)

    Rodriguez, Barbara A.; Borges, Volnei; Vilhena, Marco Tullio

    2005-01-01

    In this work we would like to obtain a formulation of an analytic method for the solution of the three dimensional transport equation considering Compton scattering and an expression for total doses due to gamma radiation, where the deposited energy by the free electron will be considered. For that, we will work with two equations: the first one for the photon transport, considering the Klein-Nishina kernel and energy multigroup model, and the second one considering the free electron with the screened Rutherford scattering. (author)

  2. The Compton polarimeter at ELSA

    International Nuclear Information System (INIS)

    Doll, D.

    1998-06-01

    In order to measure the degree of transverse polarization of the stored electron beam in the Electron Stretcher Accelerator ELSA a compton polarimeter is built up. The measurement is based on the polarization dependent cross section for the compton scattering of circular polarized photons off polarized electrons. Using a high power laser beam and detecting the scattered photons a measuring time of two minutes with a statistical error of 5% is expected from numerical simulations. The design and the results of a computer controlled feedback system to enhance the laser beam stability at the interaction point in ELSA are presented. The detection of the scattered photons is based on a lead converter and a silicon-microstrip detector. The design and test results of the detector module including readout electronic and computer control are discussed. (orig.)

  3. Compton Sources of Electromagnetic Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Geoffrey Krafft,Gerd Priebe

    2011-01-01

    When a relativistic electron beam interacts with a high-field laser beam, intense and highly collimated electromagnetic radiation will be generated through Compton scattering. Through relativistic upshifting and the relativistic Doppler effect, highly energetic polarized photons are radiated along the electron beam motion when the electrons interact with the laser light. For example, X-ray radiation can be obtained when optical lasers are scattered from electrons of tens-of-MeV beam energy. Because of the desirable properties of the radiation produced, many groups around the world have been designing, building, and utilizing Compton sources for a wide variety of purposes. In this review article, we discuss the generation and properties of the scattered radiation, the types of Compton source devices that have been constructed to date, and the prospects of radiation sources of this general type. Due to the possibilities of producing hard electromagnetic radiation in a device that is small compared to the alternative storage ring sources, it is foreseen that large numbers of such sources may be constructed in the future.

  4. Laser Compton polarimetry of proton beams

    International Nuclear Information System (INIS)

    Stillman, A.

    1995-01-01

    A need exists for non-destructive polarization measurements of the polarized proton beams in the AGS and, in the future, in RHIC. One way to make such measurements is to scatter photons from the polarized beams. Until now, such measurements were impossible because of the extremely low Compton scattering cross section from protons. Modern lasers now can provide enough photons per laser pulse not only to scatter from proton beams but also, at least in RHIC, to analyze their polarization

  5. Maximum Likelihood Compton Polarimetry with the Compton Spectrometer and Imager

    Science.gov (United States)

    Lowell, A. W.; Boggs, S. E.; Chiu, C. L.; Kierans, C. A.; Sleator, C.; Tomsick, J. A.; Zoglauer, A. C.; Chang, H.-K.; Tseng, C.-H.; Yang, C.-Y.; Jean, P.; von Ballmoos, P.; Lin, C.-H.; Amman, M.

    2017-10-01

    Astrophysical polarization measurements in the soft gamma-ray band are becoming more feasible as detectors with high position and energy resolution are deployed. Previous work has shown that the minimum detectable polarization (MDP) of an ideal Compton polarimeter can be improved by ˜21% when an unbinned, maximum likelihood method (MLM) is used instead of the standard approach of fitting a sinusoid to a histogram of azimuthal scattering angles. Here we outline a procedure for implementing this maximum likelihood approach for real, nonideal polarimeters. As an example, we use the recent observation of GRB 160530A with the Compton Spectrometer and Imager. We find that the MDP for this observation is reduced by 20% when the MLM is used instead of the standard method.

  6. ECOSP: an enhanced Compton spectrometer proposal for fresco inspection

    CERN Document Server

    Tartari, A; Lodi-Rizzini, E; Bonifazzi, C

    2001-01-01

    This paper deals with a Compton scattering technique for non-destructive testing in the inspection of fresco substrates. The aim of the Enhanced Compton Spectrometer proposal is to consider the synergic effects of both the physical design of the apparatus and data processing management, in order to obtain an enhancement in the efficiency of photon collection and a minimization of statistical needs. To this end, the study of collimators devised to enhance the collection of photons which undergo a single scattering was explored. The pixel imaging obtained by collecting the total Compton scattered photons from a hidden layer was then examined in terms of a multivariate Principal Components Analysis approach.

  7. Time-independent inverse compton spectrum for photons from a ...

    African Journals Online (AJOL)

    The general theoretical aspects of inverse Compton scattering was investigated and an equation for the timeindependent inverse Compton spectrum for photons from a plasma cloud of finite extent was derived. This was done by convolving the Kompaneets equation used for describing the evolution of the photon spectrum ...

  8. Laser Compton polarimetry at JLab and MAMI. A status report

    International Nuclear Information System (INIS)

    Diefenbach, J.; Imai, Y.; Han Lee, J.; Maas, F.; Taylor, S.

    2007-01-01

    For modern parity violation experiments it is crucial to measure and monitor the electron beam polarization continuously. In the recent years different high-luminosity concepts, for precision Compton backscattering polarimetry, have been developed, to be used at modern CW electron beam accelerator facilities. As Compton backscattering polarimetry is free of intrinsic systematic uncertainties, it can be a superior alternative to other polarimetry techniques such as Moeller and Mott scattering. State-of-the-art high-luminosity Compton backscattering designs currently in use and under development at JLab and Mainz are compared to each other. The latest results from the Mainz A4 Compton polarimeter are presented. (orig.)

  9. Noise evaluation of Compton camera imaging for proton therapy

    CERN Document Server

    Ortega, P G; Cerutti, F; Ferrari, A; Gillam, J E; Lacasta, C; Llosá, G; Oliver, J F; Sala, P R; Solevi, P; Rafecas, M

    2015-01-01

    Compton Cameras emerged as an alternative for real-time dose monitoring techniques for Particle Therapy (PT), based on the detection of prompt-gammas. As a consequence of the Compton scattering process, the gamma origin point can be restricted onto the surface of a cone (Compton cone). Through image reconstruction techniques, the distribution of the gamma emitters can be estimated, using cone-surfaces backprojections of the Compton cones through the image space, along with more sophisticated statistical methods to improve the image quality. To calculate the Compton cone required for image reconstruction, either two interactions, the last being photoelectric absorption, or three scatter interactions are needed. Because of the high energy of the photons in PT the first option might not be adequate, as the photon is not absorbed in general. However, the second option is less efficient. That is the reason to resort to spectral reconstructions, where the incoming γ energy is considered as a variable in the recons...

  10. Simulation for CZT Compton PET (Maximization of the efficiency for PET using Compton event)

    International Nuclear Information System (INIS)

    Yoon, Changyeon; Lee, Wonho; Lee, Taewoong

    2011-01-01

    Multiple interactions in positron emission tomography (PET) using scintillators are generally treated as noise events because each interacted position and energy of the multiple interactions cannot be obtained individually and the sequence of multiple scattering is not fully known. Therefore, the first interaction position, which is the crucial information for a PET image reconstruction, cannot be determined correctly. However, in the case of a pixelized semiconductor detector, such as CdZnTe, each specific position and energy information of multiple interactions can be obtained. Moreover, for the emission of two 511 keV radiations in PET, if one radiation deposits all the energy in one position (photoelectric effect) and the other radiation undergoes Compton scattering followed by the photoelectric effect, the sequence of Compton scattering followed by the photoelectric effect can be determined using the Compton scattering formula. Hence, the correct position of Compton scattering can be determined, and the Compton scattering effect, which is discarded in conventional PET systems can be recovered in the new system reported in this study. The PET system in this study, which was simulated using GATE 5.0 code, was composed of 20 mmx10 mmx10 mm CdZnTe detectors consisting of 1 mmx0.5 mmx2.5 mm pixels. The angular uncertainties caused by Doppler broadening, pixelization effect and energy broadening were estimated and compared. The pixelized effect was the main factor in increasing the angular uncertainty and was strongly dependent on the distance between the 1st and 2nd interaction positions. The effect of energy broadening to an angular resolution less than expected and that of Doppler broadening was minimal. The number of Compton events was double that of the photoelectric effect assuming full energy absorption. Therefore, the detection efficiency of this new PET system can be improved greatly because both the photoelectric effect and Compton scattering are utilized

  11. Transverse target-spin asymmetry associated with deeply virtual Compton scattering on the proton and a resulting model-dependent constraint on the total angular momentum of quarks in the nucleon

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Zhenyu

    2007-02-15

    In this thesis we report on the rst results on the transverse target-spin asymmetry associated with deeply virtual Compton scattering on the proton. It is shown that this asymmetry can provide one of the rare possibilities to access the Generalized Parton Distribution (GPD) E of the nucleon, and thus, through models for E, also to the total angular momentum of u and d quarks in the nucleon. The measurement was performed using the 27.6 GeV positron beam of the HERA storage ring and the transversely polarized hydrogen target of the HERMES experiment at DESY. The two leading azimuthal amplitudes of the asymmetry are extracted from the HERMES 2002-2004 data, corresponding to an integrated luminosity of 65.3 pb.1. By comparing the results obtained at HERMES and theoretical predictions based on a phenomenological model of GPDs, we obtain a model-dependent constraint on the total angular momentum of quarks in the nucleon. (orig.)

  12. Transverse target-spin asymmetry associated with deeply virtual Compton scattering on the proton and a resulting model-dependent constraint on the total angular momentum of quarks in the nucleon

    International Nuclear Information System (INIS)

    Ye, Zhenyu

    2007-02-01

    In this thesis we report on the rst results on the transverse target-spin asymmetry associated with deeply virtual Compton scattering on the proton. It is shown that this asymmetry can provide one of the rare possibilities to access the Generalized Parton Distribution (GPD) E of the nucleon, and thus, through models for E, also to the total angular momentum of u and d quarks in the nucleon. The measurement was performed using the 27.6 GeV positron beam of the HERA storage ring and the transversely polarized hydrogen target of the HERMES experiment at DESY. The two leading azimuthal amplitudes of the asymmetry are extracted from the HERMES 2002-2004 data, corresponding to an integrated luminosity of 65.3 pb.1. By comparing the results obtained at HERMES and theoretical predictions based on a phenomenological model of GPDs, we obtain a model-dependent constraint on the total angular momentum of quarks in the nucleon. (orig.)

  13. Neutral pion electroproduction and virtual Compton scattering on proton with four-momentum transfer squared Q2 = 1 GeV2. Measurement of cross-sections and of generalized polarizabilities

    International Nuclear Information System (INIS)

    Laveissiere, G.

    2001-11-01

    In hadronic physics, the nucleon structure and the quarks confinement are still topical issues. The neutral pion electroproduction and virtual Compton scattering (VCS) reactions allow us to access new observables that describe this structure. This work is focussed on the VCS experiment performed at Jefferson Lab in 1998. The 4 GeV electron beam is scattered off a cryogenic hydrogen target, and the scattered electron and recoiled proton are detected in coincidence in the twin hall A spectrometers. The photon (pion) is reconstructed using a missing particle technique. The data analysis allowed to extract the cross sections relative to both process at four-momentum transfer squared Q 2 = 1 GeV 2 . The VCS cross section has been extracted for the first time in the proton resonance region (W between 1.O and 2.0 GeV) through the photon electroproduction reaction. Around the pion-production threshold up to the Delta(1232) resonance region, these results lead to the measurement of the generalized polarizabilities, that describe the proton structure in the same way as the elastic form factors. Moreover, the neutral pion electroproduction cross section measurement in the resonance region has brought new constraints on the existing phenomenological models. (author)

  14. Electronic properties and Compton profiles of silver iodide

    Indian Academy of Sciences (India)

    scattering correction upto triple scattering. The contribution from the higher-order scattering is expected within the statistical errors of the experiment. Further, as suggested by our group [26], we have also corrected the experimental profile for the bremsstrahlung (BS) background due to photo and Compton recoiled electrons.

  15. From neutron Compton profiles to momentum distribution: Assessment of direct numerical determination

    International Nuclear Information System (INIS)

    Senesi, R.; Flammini, D.; Romanelli, G.; Andreani, C.

    2013-01-01

    Inelastic neutron scattering at high momentum transfers, in the neutron Compton scattering regime, provides an access to the neutron Compton profiles, the analogous of Compton profiles in X-ray scattering. The line shape analysis of the neutron Compton profiles is usually carried out making use of multiparametric nonlinear fitting, garnering detailed information about the momentum distribution of the target atoms. This paper presents the proposal to directly determine numerically the momentum distribution from the profiles, thus eliminating the possible instabilities present in multiparametric fitting. A comparison with Monte Carlo simulations and with previous measurements on polycrystalline ice provides quantitative assessments of the proposed method

  16. From neutron Compton profiles to momentum distribution: Assessment of direct numerical determination

    Energy Technology Data Exchange (ETDEWEB)

    Senesi, R., E-mail: roberto.senesi@uniroma2.it [Università degli Studi di Roma “Tor Vergata”, Dipartimento di Fisica, Via della Ricerca Scientifica 1, 00133 Roma (Italy); Centro NAST, Nanoscienze and Nanotecnologie and Strumentazione, Università degli Studi di Roma “Tor Vergata”, Via della Ricerca Scientifica 1, 00133 Roma (Italy); CNR-IPCF (Italy); Flammini, D.; Romanelli, G. [Università degli Studi di Roma “Tor Vergata”, Dipartimento di Fisica, Via della Ricerca Scientifica 1, 00133 Roma (Italy); Centro NAST, Nanoscienze and Nanotecnologie and Strumentazione, Università degli Studi di Roma “Tor Vergata”, Via della Ricerca Scientifica 1, 00133 Roma (Italy); Andreani, C. [Università degli Studi di Roma “Tor Vergata”, Dipartimento di Fisica, Via della Ricerca Scientifica 1, 00133 Roma (Italy); Centro NAST, Nanoscienze and Nanotecnologie and Strumentazione, Università degli Studi di Roma “Tor Vergata”, Via della Ricerca Scientifica 1, 00133 Roma (Italy); CNR-IPCF (Italy)

    2013-03-11

    Inelastic neutron scattering at high momentum transfers, in the neutron Compton scattering regime, provides an access to the neutron Compton profiles, the analogous of Compton profiles in X-ray scattering. The line shape analysis of the neutron Compton profiles is usually carried out making use of multiparametric nonlinear fitting, garnering detailed information about the momentum distribution of the target atoms. This paper presents the proposal to directly determine numerically the momentum distribution from the profiles, thus eliminating the possible instabilities present in multiparametric fitting. A comparison with Monte Carlo simulations and with previous measurements on polycrystalline ice provides quantitative assessments of the proposed method.

  17. Electron momentum density in Ni75Cu25 and Ni75Co25 disordered alloys: a high-resolution Compton-scattering study

    International Nuclear Information System (INIS)

    Kwiatkowska, J; Dobrzynski, L; Andrejczuk, A; Zukowski, E; Bellin, Ch; Loupias, G; Shukla, A; Buslaps, Th

    2005-01-01

    We report high-resolution Compton profiles (CPs) of Ni 75 Cu 25 and Ni 75 Co 25 disordered, ferromagnetic alloys measured along [100], [110] and [111] crystallographic directions. The directional CP anisotropies, profile derivatives and reciprocal form factors B(z) are analysed in detail and compared with first-principles KKR-CPA (Korringa-Kohn-Rostoker coherent potential approximation) calculations. Good overall agreement is found between the experimental and theoretical anisotropies. It follows from experiment that the majority-spin Fermi surface of the Ni 75 Cu 25 and Ni 75 Co 25 alloys occurs at higher momentum than the theory predicts. Also, a splitting in the secondary maxima in experimental B(z) functions of the alloys is observed, which is not predicted by the KKR-CPA calculations

  18. Angle-averaged Compton cross sections

    Energy Technology Data Exchange (ETDEWEB)

    Nickel, G.H.

    1983-01-01

    The scattering of a photon by an individual free electron is characterized by six quantities: ..cap alpha.. = initial photon energy in units of m/sub 0/c/sup 2/; ..cap alpha../sub s/ = scattered photon energy in units of m/sub 0/c/sup 2/; ..beta.. = initial electron velocity in units of c; phi = angle between photon direction and electron direction in the laboratory frame (LF); theta = polar angle change due to Compton scattering, measured in the electron rest frame (ERF); and tau = azimuthal angle change in the ERF. We present an analytic expression for the average of the Compton cross section over phi, theta, and tau. The lowest order approximation to this equation is reasonably accurate for photons and electrons with energies of many keV.

  19. Angle-averaged Compton cross sections

    International Nuclear Information System (INIS)

    Nickel, G.H.

    1983-01-01

    The scattering of a photon by an individual free electron is characterized by six quantities: α = initial photon energy in units of m 0 c 2 ; α/sub s/ = scattered photon energy in units of m 0 c 2 ; β = initial electron velocity in units of c; phi = angle between photon direction and electron direction in the laboratory frame (LF); theta = polar angle change due to Compton scattering, measured in the electron rest frame (ERF); and tau = azimuthal angle change in the ERF. We present an analytic expression for the average of the Compton cross section over phi, theta, and tau. The lowest order approximation to this equation is reasonably accurate for photons and electrons with energies of many keV

  20. Compton current detector

    International Nuclear Information System (INIS)

    Carvalho Campos, J.S. de.

    1984-01-01

    The project and construction of a Compton current detector, with cylindrical geometry using teflon as dielectric material; for electromagnetic radiation in range energy between 10 KeV and 2 MeV are described. The measurements of Compton current in teflon were obtained using an electrometer. The Compton current was promoted by photon flux proceeding from X ray sources (MG 150 Muller device) and gamma rays of 60 Co. The theory elaborated to explain the experimental results is shown. The calibration curves for accumulated charge and current in detector in function of exposition rates were obtained. (M.C.K.) [pt

  1. Deeply virtual compton scattering on the nucleon with the Clas Detector of Jefferson Lab: measurement of the polarized and unpolarized cross sections; Etude de la diffusion compton profondement virtuelle sur le nucleon avec le detecteur Clas de Jefferson Lab: mesure des sections efficaces polarisees et non polarisees

    Energy Technology Data Exchange (ETDEWEB)

    Jo, H.S

    2007-03-15

    The Generalized Parton Distributions (GPDs), introduced in the 1990's, provide the most complete description of the structure (in quarks and gluons) of the nucleon. The Deeply Virtual Compton Scattering (DVCS), which corresponds to the 'hard' exclusive electroproduction of photons on the nucleon, is a key process among the reactions allowing access to the GPDs. A DVCS-dedicated experiment was carried out in 2005 with the CLAS detector of Jefferson Lab, using a polarized electron beam of 5.776 GeV and a hydrogen target. For this experiment, we built and used a dedicated electromagnetic calorimeter capable of detecting the final-state photon. The collected data allowed us to study the DVCS in the widest kinematic range ever accessed for this reaction: 1 < Q{sup 2} < 4.6 GeV{sup 2}, 0.1 < x{sub B} < 0.58, 0.09 < -t < 2 GeV{sup 2}. The work performed during this PhD includes simulation work done for the preparation of the experiment, timing calibration of one of the CLAS subsystems, and data analysis. The aim of the data analysis was the extraction of the unpolarized cross sections of the studied reaction and of the difference of the polarized cross sections, this latter observable being linearly proportional to the GPDs. The obtained results were compared to DVCS theoretical calculations based on one of the most up-to-date GPD parametrizations. (author)

  2. Design of a polarized target made of pure HD: analysis and distillation of HD, resonant virtual Compton scattering on the nucleon at TJNAF; Developpement d'une cible polarisee de pur HD: analyse et distillation du HD, diffusion compton virtuelle resonante sur le nucleon a TJNAF

    Energy Technology Data Exchange (ETDEWEB)

    Bouchigny, S

    2004-04-01

    The first part describe my work on the frozen spin target project HYDILE. This target has to be made of very pure HD (Hydrogen Deuterium), better than 99.95%. However, commercial HD is never found with a concentration better than 98%. The goal was, then, to build an HD distillation facility which could produce pure HD. We describe, in this thesis, the design of the distillator and the implementation of a quadrupole mass spectrometer to monitor the HD purity during the distillation process. The second part of the thesis concerns the analysis taken at the electron accelerator facility TJNAF (Virginia, USA). We look at the electroproduction of Delta resonances involving Deep Virtual Compton Scattering (DeltaVCS). The interpretation of this reaction in terms of GPDs (Generalized Parton Distribution) can provide new insights to the nucleon structure. We focus on the measurement of the beam spin asymmetry which comes from the interference of the Bethe Heitler process with the DeltaVCS. (author)

  3. Compton Scattering Polarimetry for the Determination of the Proton's Weak Charge Through Measurements of the Parity-Violating Asymmetry of 1H(e,e')p

    Energy Technology Data Exchange (ETDEWEB)

    Cornejo, Juan Carlos [College of William and Mary, Williamsburg, VA (United States); Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2016-08-01

    The Standard Model has been a theory with the greatest success in describing the fundamental interactions of particles. As of the writing of this dissertation, the Standard Model has not been shown to make a false prediction. However, the limitations of the Standard Model have long been suspected by its lack of a description of gravity, nor dark matter. Its largest challenge to date, has been the observation of neutrino oscillations, and the implication that they may not be massless, as required by the Standard Model. The growing consensus is that the Standard Model is simply a lower energy effective field theory, and that new physics lies at much higher energies. The Qweak Experiment is testing the Electroweak theory of the Standard Model by making a precise determination of the weak charge of the proton (Qpw). Any signs of "new physics" will appear as a deviation to the Standard Model prediction. The weak charge is determined via a precise measurement of the parity-violating asymmetry of the electron-proton interaction via elastic scattering of a longitudinally polarized electron beam of an un-polarized proton target. The experiment required that the electron beam polarization be measured to an absolute uncertainty of 1%. At this level the electron beam polarization was projected to contribute the single largest experimental uncertainty to the parity-violating asymmetry measurement. This dissertation will detail the use of Compton scattering to determine the electron beam polarization via the detection of the scattered photon. I will conclude the remainder of the dissertation with an independent analysis of the blinded Qweak.

  4. Geometrical effects determinant of the Compton profile shape

    International Nuclear Information System (INIS)

    Sartori, Renzo; Mainardi, R.T.

    1987-01-01

    The main purpose of this work is to evaluate the influence of the experimental set up on the shape of the Compton line. In any scattering experiment, the scattering angle is not well defined due to the collimators aperture and thus, a distribution of angles is found for each set up. This, in turn, produces the energies' distribution of the scattered photons around a mean value. This contribution has been evaluated and found it to be significant for several cases. In order to do this evaluation, a response function, that is numerically generated for each experimental set up and convoluted with the Compton profile, was defined. (Author) [es

  5. Stochastic Electrodynamics and the Compton effect

    International Nuclear Information System (INIS)

    Franca, H.M.; Barranco, A.V.

    1987-12-01

    Some of the main qualitative features of the Compton effect are tried to be described within the realm of Classical Stochastic Electrodynamics (SED). It is found indications that the combined action of the incident wave (frequency ω), the radiation reaction force and the zero point fluctuating electromagnetic fields of SED, are able to given a high average recoil velocity v/c=α/(1+α) to the charged particle. The estimate of the parameter α gives α ∼ ℎω/mc 2 where 2Πℎ is the constant and mc 2 is the rest energy of the particle. It is verified that this recoil is just that necessary to explain the frequency shift, observed in the scattered radiation as due to a classical double Doppler shift. The differential cross section for the radiation scattered by the recoiling charge using classical electromagnetism also calculated. The same expression as obtained by Compton in his fundamental work of 1923 is found. (author) [pt

  6. Study of single Z-boson production and Compton scattering in electron-positron collisions at LEP at centre-of-mass energies up to 209 GeV

    CERN Document Server

    Vasquez Sierra, Ricardo

    2006-01-01

    This thesis discusses two main topics. First, the cross section of the process e + e - [arrow right]Ze + e - is measured with 0.7 ph - of data collected with the L3 detector at LEP. Decays of the Z boson into quarks and muons are considered at center-of-mass energies ranging frond 183 GeV up to 209 GeV. The measurements are found to agree with Standard Model predictions, achieving a precision of about 10% for the hadronic channel. Second, Compton scattering of quasi-real virtual photons, γe ± [arrow right]γe ± , is studied with 0.6 fb - 1 of data collected by the L3 detector at LEP at center-of-mass energies [Special characters omitted.] = 189--209GeV. About 4500 events produced by the interaction of virtual photons emitted by particles of one beam with particles of the opposite beam are collected for effective center-of-mass energies of photon-electron and photon-positron systems in the range [Special characters omitted.] = 35 GeV up to [Special characters omitted.] = 175 GeV, the highest energy at which...

  7. The Compton generator revisited

    Science.gov (United States)

    Siboni, S.

    2014-09-01

    The Compton generator, introduced in 1913 by the US physicist A H Compton as a relatively simple device to detect the Earth's rotation with respect to the distant stars, is analyzed and discussed in a general perspective. The paper introduces a generalized definition of the generator, emphasizing the special features of the original apparatus, and provides a suggestive interpretation of the way the device works. To this end, an intriguing electromagnetic analogy is developed, which turns out to be particularly useful in simplifying the calculations. Besides the more extensive description of the Compton generator in itself, the combined use of concepts and methods coming from different fields of physics, such as particle dynamics in moving references frames, continuum mechanics and electromagnetism, may be of interest to both teachers and graduate students.

  8. Inclusive and Exclusive Compton Processes in Quantum Chromodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Psaker, Ales [Old Dominion Univ., Norfolk, VA (United States)

    2005-12-01

    In our work, we describe two types of Compton processes. As an example of an inclusive process, we consider the high-energy photoproduction of massive muon pairs off the nucleon. We analyze the process in the framework of the QCD parton model, in which the usual parton distributions emerge as a tool to describe the nucleon in terms of quark and gluonic degrees of freedom. To study its exclusive version, a new class of phenomenological functions is required, namely, generalized parton distributions. They can be considered as a generalization of the usual parton distributions measured in deeply inelastic lepton-nucleon scattering. Generalized parton distributions (GPDs) may be observed in hard exclusive reactions such as deeply virtual Compton scattering. We develop an extension of this particular process into the weak interaction sector. We also investigate a possible application of the GPD formalism to wide-angle real Compton scattering.

  9. Compton backscattering axial spectrometer

    International Nuclear Information System (INIS)

    Rad'ko, V.E.; Mokrushin, A.D.; Razumovskaya, I.V.

    1981-01-01

    Compton gamma backscattering axial spectrometer of new design with the 200 time larger aperture as compared with the known spectrometers at the equal angular resolution (at E=159 keV) is described. Collimator unit, radiation source and gamma detector are located in the central part of the spectrometer. The investigated specimen (of cylindrical form) and the so called ''black body'' used for absorption of photons, passed through the specimen are placed in the peripheric part. Both these parts have an imaginary symmetry axis that is why the spectrometer is called axial. 57 Co is used as the gamma source. The 122 keV spectral line which corresponds to the 83 keV backscattered photon serves as working line. Germanium disk detector of 10 mm diameter and 4 mm height has energy resolution not worse than 900 eV. The analysis of results of test measurements of compton water profile and their comparison with data obtained earlier show that only finity of detector resolution can essentially affect the form of Compton profile. It is concluded that the suggested variant of the spectrometer would be useful for determination of Compton profiles of chemical compounds of heavy elements [ru

  10. Compton profile of tantalum

    Indian Academy of Sciences (India)

    The Compton profile of tantalum (Ta) has been measured using IGP type coaxial photon detector. The target atoms were excited by means of 59.54 keV -rays from Am-241. The measurements were carried out on a high purity thin elemental foil. The data were recoreded in a 4 K multichannel analyzer. These data duly ...

  11. Beam dynamics simulation in the X-ray Compton source

    Energy Technology Data Exchange (ETDEWEB)

    Gladkikh, P.; Karnaukhov, I.; Telegin, Yu.; Shcherbakov, A. E-mail: shcherbakov@kipt.kharkov.ua; Zelinsky, A

    2002-05-01

    At the National Science Center 'Kharkov Institute of Physics and Technology' the X-ray source based on Compton scattering has been developed. The computer code for simulation of electron beam dynamics with taking into account the Compton scattering effect based on Monte Carlo method is described in this report. The first results of computer simulation of beam dynamics with electron-photon interaction, parameters of electron and photon beams are presented. Calculations were carried out with the lattice of synchrotron light source SRS-800 Ukrainian Synchrotron Center.

  12. Beam dynamics simulation in the X-ray Compton source

    International Nuclear Information System (INIS)

    Gladkikh, P.; Karnaukhov, I.; Telegin, Yu.; Shcherbakov, A.; Zelinsky, A.

    2002-01-01

    At the National Science Center 'Kharkov Institute of Physics and Technology' the X-ray source based on Compton scattering has been developed. The computer code for simulation of electron beam dynamics with taking into account the Compton scattering effect based on Monte Carlo method is described in this report. The first results of computer simulation of beam dynamics with electron-photon interaction, parameters of electron and photon beams are presented. Calculations were carried out with the lattice of synchrotron light source SRS-800 Ukrainian Synchrotron Center

  13. Beam dynamics simulation in the X-ray Compton source

    CERN Document Server

    Gladkikh, P; Telegin, Yu P; Shcherbakov, A; Zelinsky, A

    2002-01-01

    At the National Science Center 'Kharkov Institute of Physics and Technology' the X-ray source based on Compton scattering has been developed. The computer code for simulation of electron beam dynamics with taking into account the Compton scattering effect based on Monte Carlo method is described in this report. The first results of computer simulation of beam dynamics with electron-photon interaction, parameters of electron and photon beams are presented. Calculations were carried out with the lattice of synchrotron light source SRS-800 Ukrainian Synchrotron Center.

  14. Helium Compton Form Factor Measurements at CLAS

    Energy Technology Data Exchange (ETDEWEB)

    Voutier, Eric J.-M. [Laboratoire de Physique Subatomique et Cosmologie

    2013-07-01

    The distribution of the parton content of nuclei, as encoded via the generalized parton distributions (GPDs), can be accessed via the deeply virtual Compton scattering (DVCS) process contributing to the cross section for leptoproduction of real photons. Similarly to the scattering of light by a material, DVCS provides information about the dynamics and the spatial structure of hadrons. The sensitivity of this process to the lepton beam polarization allows to single-out the DVCS amplitude in terms of Compton form factors that contain GPDs information. The beam spin asymmetry of the $^4$He($\\vec {\\mathrm e}$,e$' \\gamma ^4$He) process was measured in the experimental Hall B of the Jefferson Laboratory to extract the real and imaginary parts of the twist-2 Compton form factor of the $^4$He nucleus. The experimental results reported here demonstrate the relevance of this method for such a goal, and suggest the dominance of the Bethe-Heitler amplitude to the unpolarized process in the kinematic range explored by the experiment.

  15. Use of a lowest intensity 241Am Compton spectrometer for the measurement of directional Compton profiles of ZnSe

    International Nuclear Information System (INIS)

    Ahuja, B.L.; Heda, N.L.

    2006-01-01

    In this paper we report on electron momentum densities in ZnSe using Compton scattering technique. For the directional measurements we have employed a newly developed 100 mCi 241 Am Compton spectrometer which is based on a small disc source with shortest geometry. For the theoretical calculations we have employed a self-consistent Hartree-Fock linear combination of atomic orbitals (HF-LCAO) approach. It is seen that the anisotropy in the measured Compton profiles is well reproduced by our HF-LCAO calculation and the other available pseudopotential data. The anisotropy in the Compton profiles is explained in terms of energy bands and bond length. - PACS numbers: 13.60.Fz, 78.70. Ck, 78.70.-g (orig.)

  16. The Compton Camera - medical imaging with higher sensitivity Exhibition LEPFest 2000

    CERN Multimedia

    2000-01-01

    The Compton Camera reconstructs the origin of Compton-scattered X-rays using electronic collimation with Silicon pad detectors instead of the heavy conventional lead collimators in Anger cameras - reaching up to 200 times better sensitivity and a factor two improvement in resolution. Possible applications are in cancer diagnosis, neurology neurobiology, and cardiology.

  17. Measurement of the spin asymmetry of the beam in the polarized virtual Compton scattering on the proton. Study of the nucleon's energy spectra through the QCD-type potential model; Mesure de l'asymetrie de spin de faisceau en diffusion compton virtuelle polarisee sur le proton. Etude du spectre d'energie du nucleon par le modele de potentiel de type QCD

    Energy Technology Data Exchange (ETDEWEB)

    Bensafa, I.K

    2006-05-15

    The first part of this work presents the analysis and results of the VCS-SSA (virtual Compton scattering - single spin asymmetry) experiment at MAMI (Mainz). It was carried out with beam energy 883 MeV and longitudinal polarization (about 80%), at virtual photon four-momentum transfer squared (Q{sup 2} = 0.35 GeV{sup 2}) to measure the beam asymmetry in the ep {yields} ep{gamma} and ep {yields} ep{pi}{sup 0} reactions. The asymmetry obtained in photon (resp. pion) electro-production is between 0-15% (resp. 0-2%). The dispersion relation model for virtual Compton scattering and MAID model (for {pi}{sup 0}) reproduce the amplitude globally but not completely the shape of the asymmetry. Perhaps this discrepancy is due to an imperfect parameterization of some pion production multipoles ({gamma}{sup *}N {yields} {pi}N). The second part is dedicated to the study of the nucleon energy spectrum in ground-state L=0 and excited-state L=1 in the quark model, using the Coulomb + linear potential type (CL) and a relativistic correction. The hyperfine correction is applied to discriminate the nucleon masses. The values of the mass found for the proton and the {delta}(1232) are respectively equal to (968 MeV, 1168 MeV), and the masses of the excited states are between 1564 - 1607 MeV. This part is completed by an application of the CL model to an approximate calculation of generalized polarizabilities of the proton. (author)

  18. Further Study on Fast Cooling in Compton Storage Rings

    CERN Document Server

    Bulyak, Eugene; Zimmermann, Frank

    2012-01-01

    Compton sources of gamma-ray photons can produce ultimate intensity, but suffer from large recoils experienced by the circulating electrons scattering off the laser photons. We had proposed the asymmetric fast cooling which enables to mitigate the spread of energy in Compton rings. This report presents results of further study on the fast cooling: (1) A proper asymmetric setup of the scattering point results in significant reduction of the quantum losses of electrons in Compton rings with moderate energy acceptance. (2) Proposed pulsed mode of operation in synchrotron–dominated rings enhances overall performance of such gamma-ray sources. Theoretical results are in good accordance with the simulations. Performance of an existing storage ring equipped with a laser system is also evaluated.

  19. Compton profiles of some composite materials normalized by a new method

    Science.gov (United States)

    Sankarshan, B. M.; Umesh, T. K.

    2018-03-01

    Recently, we have shown that as a novel approach, in the case of samples which can be treated as pure incoherent scatterers, the effective atomic number Zeff itself could be conveniently used to normalize their un-normalized Compton profiles. In the present investigation, we have attempted to examine the efficacy of this approach. For this purpose, we have first determined the single differential Compton scattering cross sections (SDCS) of the elements C and Al as well as of some H, C, N and O based polymer samples such as bakelite, epoxy, nylon and teflon which are pure incoherent scatterers. The measurements were made at 120° in a goniometer assembly that employs a high resolution high purity germanium detector. The SDCS values were used to obtain the Zeff and the un-normalized Compton profiles. These Compton profiles were separately normalized with their Zeff values (for Compton scattering) as well as with the normalization constant obtained by integrating their Hartree-Fock Biggs et al Compton profiles based on the mixture rule. These two sets of values agreed well within the range of experimental errors, implying that Zeff can be conveniently used to normalize the experimental Compton profiles of pure incoherent scatterers.

  20. New reconstruction method for the advanced compton camera

    International Nuclear Information System (INIS)

    Kurihara, Takashi; Ogawa, Koichi

    2007-01-01

    Conventional gammacameras employ a mechanical collimator, which reduces the number of photons detected by such cameras. To address this issue, a Compton camera has been proposed to improve the efficiency of data acquisition by employing electronic collimation. With regard to Compton cameras, the advanced Compton camera (ACC) which has been proposed by Tanimori et al. can restrict the source locations with the help of the recoil electrons that are emitted in the process of Compton scattering. However, the reconstruction methods employed in conventional Compton cameras are inefficient in reconstructing images from the data acquired with the ACC. In this paper, we propose a new reconstruction method that is designed specifically for the ACC. This method, which is an improved version of the source space tree algorithm (SSTA), permits the source distribution to be reconstructed accurately and efficiently. The SSTA is one of the reconstruction methods for conventional Compton cameras proposed by Rohe et al. Our proposed algorithm employs a set of lines that are defined at equiangular intervals in the reconstruction region and the specified voxels of interest that include the search points located on the above predefined lines at equally spaced intervals. The validity of our method is demonstrated by simulations involving the reconstruction of a point source and a disk source. (author)

  1. Few arc-minute and keV resolutions with the TIGRE Compton telescope

    Science.gov (United States)

    Zych, A.; Bhattacharya, D.; Dixon, D.; ONeill, T.; Tuemer, T.; White, R. S.; Ryan, J.; McConnell, M.; Macri, J.; Oegelman, H.; hide

    1997-01-01

    The tracking and imaging gamma ray experiment (TIGRE) Compton telescope concept can provide an angular resolution of a few arcmin, an energy resolution of a few keV and high sensitivity, while providing the wide field of view necessary for surveying and monitoring observations. Silicon and CdZnTe strip detectors are used to detect Compton pair events and determine their incident directions and energies. Above 400 keV, Compton recoil electrons are tracked through successive layers of thin silicon strip detectors. Compton scattered photons are detected with CdZnTe strip detectors. Pair electrons and positrons are tracked to provide high sensitivity observations in the 10 to 100 MeV range. Polarization studies are performed with large angle Compton scatter events. The TIGRE concept and development status are described.

  2. Attenuation studies near K-absorption edges using Compton ...

    Indian Academy of Sciences (India)

    journal of. April 2008 physics pp. 633–641. Attenuation studies near K-absorption edges using. Compton scattered 241Am gamma rays. K K ABDULLAH1, N RAMACHANDRAN2, K KARUNAKARAN NAIR3,. B R S BABU4, ANTONY JOSEPH4, RAJIVE .... A Linux-based package,. 634. Pramana – J. Phys., Vol. 70, No.

  3. Attenuation studies near K-absorption edges using Compton ...

    Indian Academy of Sciences (India)

    The results are consistent with theoretical values derived from the XCOM package. Keywords. Photon interaction; 241Am; gamma ray attenuation; Compton scattering; absorption edge; rare earth elements. PACS Nos 32.80.-t; 32.90.+a. 1. Introduction. Photon interaction studies at energies around the absorption edge have ...

  4. Inverse Compton Gamma Rays from Dark Matter Annihilation in the ...

    Indian Academy of Sciences (India)

    As the e + e − − energy spectra have an exponential cut off at high energies, this may allow to discriminate some dark matter scenarios from other astrophysical sources. Finally, some more detailed study about the effect of inverse Compton scattering may help constrain the dark matter signature in the dSph galaxies.

  5. Spectra of clinical CT scanners using a portable Compton spectrometer

    International Nuclear Information System (INIS)

    Duisterwinkel, H. A.; Abbema, J. K. van; Kawachimaru, R.; Paganini, L.; Graaf, E. R. van der; Brandenburg, S.; Goethem, M. J. van

    2015-01-01

    Purpose: Spectral information of the output of x-ray tubes in (dual source) computer tomography (CT) scanners can be used to improve the conversion of CT numbers to proton stopping power and can be used to advantage in CT scanner quality assurance. The purpose of this study is to design, validate, and apply a compact portable Compton spectrometer that was constructed to accurately measure x-ray spectra of CT scanners. Methods: In the design of the Compton spectrometer, the shielding materials were carefully chosen and positioned to reduce background by x-ray fluorescence from the materials used. The spectrum of Compton scattered x-rays alters from the original source spectrum due to various physical processes. Reconstruction of the original x-ray spectrum from the Compton scattered spectrum is based on Monte Carlo simulations of the processes involved. This reconstruction is validated by comparing directly and indirectly measured spectra of a mobile x-ray tube. The Compton spectrometer is assessed in a clinical setting by measuring x-ray spectra at various tube voltages of three different medical CT scanner x-ray tubes. Results: The directly and indirectly measured spectra are in good agreement (their ratio being 0.99) thereby validating the reconstruction method. The measured spectra of the medical CT scanners are consistent with theoretical spectra and spectra obtained from the x-ray tube manufacturer. Conclusions: A Compton spectrometer has been successfully designed, constructed, validated, and applied in the measurement of x-ray spectra of CT scanners. These measurements show that our compact Compton spectrometer can be rapidly set-up using the alignment lasers of the CT scanner, thereby enabling its use in commissioning, troubleshooting, and, e.g., annual performance check-ups of CT scanners

  6. Spectra of clinical CT scanners using a portable Compton spectrometer.

    Science.gov (United States)

    Duisterwinkel, H A; van Abbema, J K; van Goethem, M J; Kawachimaru, R; Paganini, L; van der Graaf, E R; Brandenburg, S

    2015-04-01

    Spectral information of the output of x-ray tubes in (dual source) computer tomography (CT) scanners can be used to improve the conversion of CT numbers to proton stopping power and can be used to advantage in CT scanner quality assurance. The purpose of this study is to design, validate, and apply a compact portable Compton spectrometer that was constructed to accurately measure x-ray spectra of CT scanners. In the design of the Compton spectrometer, the shielding materials were carefully chosen and positioned to reduce background by x-ray fluorescence from the materials used. The spectrum of Compton scattered x-rays alters from the original source spectrum due to various physical processes. Reconstruction of the original x-ray spectrum from the Compton scattered spectrum is based on Monte Carlo simulations of the processes involved. This reconstruction is validated by comparing directly and indirectly measured spectra of a mobile x-ray tube. The Compton spectrometer is assessed in a clinical setting by measuring x-ray spectra at various tube voltages of three different medical CT scanner x-ray tubes. The directly and indirectly measured spectra are in good agreement (their ratio being 0.99) thereby validating the reconstruction method. The measured spectra of the medical CT scanners are consistent with theoretical spectra and spectra obtained from the x-ray tube manufacturer. A Compton spectrometer has been successfully designed, constructed, validated, and applied in the measurement of x-ray spectra of CT scanners. These measurements show that our compact Compton spectrometer can be rapidly set-up using the alignment lasers of the CT scanner, thereby enabling its use in commissioning, troubleshooting, and, e.g., annual performance check-ups of CT scanners.

  7. The development of a Compton lung densitometer

    Energy Technology Data Exchange (ETDEWEB)

    Loo, B.W.; Goulding, F.S.; Madden, N.W.; Simon, D.S.

    1988-11-01

    A field instrument is being developed for the non-invasive determination of absolute lung density using unique Compton backscattering techniques. A system consisting of a monoenergetic gamma-ray beam and a shielded high resolution high-purity-germanium (HPGe) detector in a close-coupled geometry is designed to minimize errors due to multiple scattering and uncontrollable attenuation in the chestwall. Results of studies on system performance with phantoms, the optimization of detectors, and the fabrication of a practical gamma-ray source are presented. 3 refs., 6 figs., 2 tabs.

  8. Proton compton scattering in dispersion relation analysis

    International Nuclear Information System (INIS)

    Dumbrajs, Olgierd.

    1978-01-01

    Inserting a logarithmically rising total photon-proton cross section into dispersion relation we update our theoretical knowledge about the forward real part. Taking into account analytic properties of the amplitude in the cosTHETA-variable we find that at low energies our experimental knowledge about this quantity should be modified. (author)

  9. Dispersion relation analysis of proton Compton scattering

    International Nuclear Information System (INIS)

    Dumbrajs, O.

    1979-01-01

    Inserting a logarithmically rising total photon-proton cross section into the dispersion relation, theoretical knowledge about the forward real part is updated. Taking into account analytic properties of the amplitude in the cos theta variable it is found that at low energies, experimental knowledge about this quantity should be reassessed. (Auth.)

  10. Experimental and theoretical Compton profiles of Be, C and Al

    Energy Technology Data Exchange (ETDEWEB)

    Aguiar, Julio C., E-mail: jaguiar@arn.gob.a [Autoridad Regulatoria Nuclear, Av. Del Libertador 8250, C1429BNP, Buenos Aires (Argentina); Instituto de Fisica ' Arroyo Seco' , Facultad de Ciencias Exactas, U.N.C.P.B.A., Pinto 399, 7000 Tandil (Argentina); Di Rocco, Hector O. [Instituto de Fisica ' Arroyo Seco' , Facultad de Ciencias Exactas, U.N.C.P.B.A., Pinto 399, 7000 Tandil (Argentina); Arazi, Andres [Laboratorio TANDAR, Comision Nacional de Energia Atomica, Av. General Paz 1499, 1650 San Martin, Buenos Aires (Argentina)

    2011-02-01

    The results of Compton profile measurements, Fermi momentum determinations, and theoretical values obtained from a linear combination of Slater-type orbital (STO) for core electrons in beryllium; carbon and aluminium are presented. In addition, a Thomas-Fermi model is used to estimate the contribution of valence electrons to the Compton profile. Measurements were performed using monoenergetic photons of 59.54 keV provided by a low-intensity Am-241 {gamma}-ray source. Scattered photons were detected at 90{sup o} from the beam direction using a p-type coaxial high-purity germanium detector (HPGe). The experimental results are in good agreement with theoretical calculations.

  11. Advanced Source Deconvolution Methods for Compton Telescopes

    Science.gov (United States)

    Zoglauer, Andreas

    The next generation of space telescopes utilizing Compton scattering for astrophysical observations is destined to one day unravel the mysteries behind Galactic nucleosynthesis, to determine the origin of the positron annihilation excess near the Galactic center, and to uncover the hidden emission mechanisms behind gamma-ray bursts. Besides astrophysics, Compton telescopes are establishing themselves in heliophysics, planetary sciences, medical imaging, accelerator physics, and environmental monitoring. Since the COMPTEL days, great advances in the achievable energy and position resolution were possible, creating an extremely vast, but also extremely sparsely sampled data space. Unfortunately, the optimum way to analyze the data from the next generation of Compton telescopes has not yet been found, which can retrieve all source parameters (location, spectrum, polarization, flux) and achieves the best possible resolution and sensitivity at the same time. This is especially important for all sciences objectives looking at the inner Galaxy: the large amount of expected sources, the high background (internal and Galactic diffuse emission), and the limited angular resolution, make it the most taxing case for data analysis. In general, two key challenges exist: First, what are the best data space representations to answer the specific science questions? Second, what is the best way to deconvolve the data to fully retrieve the source parameters? For modern Compton telescopes, the existing data space representations can either correctly reconstruct the absolute flux (binned mode) or achieve the best possible resolution (list-mode), both together were not possible up to now. Here we propose to develop a two-stage hybrid reconstruction method which combines the best aspects of both. Using a proof-of-concept implementation we can for the first time show that it is possible to alternate during each deconvolution step between a binned-mode approach to get the flux right and a

  12. SCATTER

    International Nuclear Information System (INIS)

    Broome, J.

    1965-11-01

    The programme SCATTER is a KDF9 programme in the Egtran dialect of Fortran to generate normalized angular distributions for elastically scattered neutrons from data input as the coefficients of a Legendre polynomial series, or from differential cross-section data. Also, differential cross-section data may be analysed to produce Legendre polynomial coefficients. Output on cards punched in the format of the U.K. A. E. A. Nuclear Data Library is optional. (author)

  13. Compton Ring with Laser Radiative Cooling

    Science.gov (United States)

    Bulyak, E.; Urakawa, J.; Zimmermann, F.

    2013-10-01

    Proposed is an enhancement of laser radiative cooling by utilizing laser pulses of small spatial and temporal dimensions, which interact only with a fraction of an electron bunch circulating in a storage ring. The dynamics of such electron bunch when laser photons scatter off the electrons at a collision point placed in a section with nonzero dispersion is studied. In this case of `asymmetric cooling', the stationary energy spread is much smaller than under conditions of regular scattering where the laser spot size is larger than the electron beam; and the synchrotron oscillations are damped faster. Results of extensive simulations are presented for the performance optimization of Compton gamma-ray sources and damping rings.

  14. Neutron diagnostics using compton suppression gamma-ray spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Hong, S. P.; Kang, B. S. [Lab. Of Radiation Convergence Science, Dept. of Radiological Science, College of Medical Science, Konyang University, Daejeon (Korea, Republic of); Kim, C. S.; Cheon, M. S.; Cho, S. [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2016-12-15

    Various neutron diagnostic systems such as a fission chamber, stilbene spectrometers, and a neutron activation system (NAS) have been installed at KSTAR for more accurate detection of neutron flux. Among the systems, the NAS is the most reliable and robust tool, and the measurement data of it generally are to be used for calibration of other systems. The Compton suppression gamma-ray spectrometer which can suppress the expected background, noise signal and Compton scattering was used to measure the gamma-rays of neutron activated samples. In this study, the encapsulated indium samples which are installed and irradiated by the neutrons released from the nuclear fusion reactions in the Korea Superconducting Tokamak Advanced Research (KSTAR) was used and measured using Compton suppressed gamma-ray spectrometer to minimize the measurement error. From the experimental results, the statistical error was decreased by Compton suppression system. the statistical error of the measured sample activity in the Compton suppressed system is estimated to be about 2.3 %, and the statistical error of the measured sample activity in the non-suppressed system was estimated to be about 4.9 %. It was found that the system can reduce the measurement error effectively. It is confirmed that this system can be applied to ITER TBM and future nuclear fusion devices.

  15. Modulated method for efficient, narrow-bandwidth, laser Compton X-ray and gamma-ray sources

    Science.gov (United States)

    Barty, Christopher P. J.

    2017-07-11

    A method of x-ray and gamma-ray generation via laser Compton scattering uses the interaction of a specially-formatted, highly modulated, long duration, laser pulse with a high-frequency train of high-brightness electron bunches to both create narrow bandwidth x-ray and gamma-ray sources and significantly increase the laser to Compton photon conversion efficiency.

  16. Scattered X-ray beam nondestructive testing

    International Nuclear Information System (INIS)

    Harding, G.; Kosanetzky, J.

    1988-01-01

    X-ray scatter interactions generally dominate the linear attenuation coefficient at the photon energies typical of medical and industrial radiography. Specific advantages of X-ray scatter imaging, including a flexible choice of measurement geometry, direct 3D-imaging capability (tomography) and improved information for material characterization, are illustrated with results from Compton and coherent scatter devices. Applications of a Compton backscatter scanner (ComScan) in the aerospace industry and coherent scatter imaging in security screening are briefly considered [pt

  17. Compton suppression gamma ray spectrometry

    International Nuclear Information System (INIS)

    Landsberger, S.; Iskander, F.Y.; Niset, M.; Heydorn, K.

    2002-01-01

    In the past decade there have been many studies to use Compton suppression methods in routine neutron activation analysis as well as in the traditional role of low level gamma ray counting of environmental samples. On a separate path there have been many new PC based software packages that have been developed to enhance photopeak fitting. Although the newer PC based algorithms have had significant improvements, they still suffer from being effectively used in weak gamma ray lines in natural samples or in neutron activated samples that have very high Compton backgrounds. We have completed a series of experiments to show the usefulness of Compton suppression. As well we have shown the pitfalls when using Compton suppression methods for high counting deadtimes as in the case of neutron activated samples. We have also investigated if counting statistics are the same both suppressed and normal modes. Results are presented in four separate experiments. (author)

  18. On the timing properties of germanium detectors: The centroid diagrams of prompt photopeaks and Compton events

    International Nuclear Information System (INIS)

    Penev, I.; Andrejtscheff, W.; Protochristov, Ch.; Zhelev, Zh.

    1987-01-01

    In the applications of the generalized centroid shift method with germanium detectors, the energy dependence of the time centroids of prompt photopeaks (zero-time line) and of Compton background events reveal a peculiar behavior crossing each other at about 100 keV. The effect is plausibly explained as associated with the ratio of γ-quanta causing the photoeffect and Compton scattering, respectively, at the boundaries of the detector. (orig.)

  19. Multipass optical cavity for inverse Compton interactions

    Energy Technology Data Exchange (ETDEWEB)

    Rollason, A.J. E-mail: a.j.rollason@keele.ac.uk; Fang, X.; Dugdale, D.E

    2004-07-01

    The recycling of laser beams in the focal region of non-resonant multipass optical cavities has been investigated as a means of providing a high intensity of photons for weak interaction experiments. Ray-tracing simulations and measurements with an Ar-ion laser have been carried out to examine the intensity profiles of the laser field in different 2-mirror geometries. In particular, the use of such cavities in the generation of X-rays by inverse Compton scattering is considered. X-ray yields are calculated for electron beams of 0.05, 0.1, 0.2 and 0.5 mm diameter yielding enhancement factors of 10-200 compared to a free space laser interaction.

  20. Inverse comptonization vs. thermal synchrotron

    International Nuclear Information System (INIS)

    Fenimore, E.E.; Klebesadel, R.W.; Laros, J.G.

    1983-01-01

    There are currently two radiation mechanisms being considered for gamma-ray bursts: thermal synchrotron and inverse comptonization. They are mutually exclusive since thermal synchrotron requires a magnetic field of approx. 10 12 Gauss whereas inverse comptonization cannot produce a monotonic spectrum if the field is larger than 10 11 and is too inefficient relative to thermal synchrotron unless the field is less than 10 9 Gauss. Neither mechanism can explain completely the observed characteristics of gamma-ray bursts. However, we conclude that thermal synchrotron is more consistent with the observations if the sources are approx. 40 kpc away whereas inverse comptonization is more consistent if they are approx. 300 pc away. Unfortunately, the source distance is still not known and, thus, the radiation mechanism is still uncertain

  1. Compton echoes from nearby Gamma-Ray Bursts

    Science.gov (United States)

    Beniamini, Paz; Giannios, Dimitrios; Younes, George; van der Horst, Alexander J.; Kouveliotou, Chryssa

    2018-03-01

    The recent discovery of gravitational waves from GW170817, associated with a short Gamma-Ray Burst (GRB) at a distance of 40Mpc, has demonstrated that short GRBs can occur locally and at a reasonable rate. Furthermore, gravitational waves enable us to detect close by GRBs, even when we are observing at latitudes far from the jet's axis. We consider here Compton echoes, the scattered light from the prompt and afterglow emission. Compton echoes, an as yet undetected counterpart of GRBs, peak in X-rays and maintain a roughly constant flux for hundreds to thousands of years after the burst. Though too faint to be detected in typical cosmological GRBs, a fraction of close by bursts with a sufficiently large energy output in X-rays, and for which the surrounding medium is sufficiently dense, may indeed be observed in this way. The detection of a Compton echo could provide unique insight into the burst properties and the environment's density structure. In particular, it could potentially determine whether or not there was a successful jet that broke through the compact binary merger ejecta. We discuss here the properties and expectations from Compton echoes and suggest methods for detectability.

  2. Evaluation of double photon coincidence Compton imaging method with GEANT4 simulation

    Science.gov (United States)

    Yoshihara, Yuri; Shimazoe, Kenji; Mizumachi, Yuki; Takahashi, Hiroyuki

    2017-11-01

    Compton imaging has been used for various applications including astronomical observations, radioactive waste management, and biomedical imaging. The positions of radioisotopes are determined in the intersections of multiple cone traces through a large number of events, which reduces signal to noise ratio (SNR) of the images. We have developed an advanced Compton imaging method to localize radioisotopes with high SNR by using information of the interactions of Compton scattering caused by two gamma rays at the same time, as the double photon coincidence Compton imaging method. The targeted radioisotopes of this imaging method are specific nuclides that emit several gamma rays at the same time such as 60Co, 134Cs, and 111In, etc. Since their locations are determined in the intersections of two Compton cones, the most of cone traces would disappear in the three-dimensional space, which enhances the SNR and angular resolution. In this paper, the comparison of the double photon coincidence Compton imaging method and the single photon Compton imaging method was conducted by using GEANT4 Monte Carlo simulation.

  3. Crick, Prof. Francis Harry Compton

    Indian Academy of Sciences (India)

    Elected: 1985 Honorary. Crick, Prof. Francis Harry Compton O.M., FRS, Nobel Laureate (Medicine) - 1962. Date of birth: 8 June 1916. Date of death: 29 July 2004. Last known address: The Salk Institute for Biological, Studies, P.O. Box 85800, San Diego, CA 92186-5800, U.S.A.. YouTube; Twitter; Facebook; Blog ...

  4. A possible role for silicon microstrip detectors in nuclear medicine: Compton imaging of positron emitters

    Science.gov (United States)

    Scannavini, M. G.; Speller, R. D.; Royle, G. J.; Cullum, I.; Raymond, M.; Hall, G.; Iles, G.

    2002-01-01

    Collimation of gamma-rays based on Compton scatter could provide in principle high resolution and high sensitivity, thus becoming an advantageous method for the imaging of radioisotopes of clinical interest. A small laboratory prototype of a Compton camera is being constructed in order to initiate studies aimed at assessing the feasibility of Compton imaging of positron emitters. The design of the camera is based on the use of a silicon collimator consisting of a stack of double-sided, AC-coupled microstrip detectors (area 6×6 cm 2, 500 μm thickness, 128 channels/side). Two APV6 chips are employed for signal readout on opposite planes of each detector. This work presents the first results on the noise performance of the silicon strip detectors. Measurements of the electrical characteristics of the detector are also reported. On the basis of the measured noise, an angular resolution of approximately 5° is predicted for the Compton collimator.

  5. A possible role for silicon microstrip detectors in nuclear medicine Compton imaging of positron emitters

    CERN Document Server

    Scannavini, M G; Royle, G J; Cullum, I; Raymond, M; Hall, G; Iles, G

    2002-01-01

    Collimation of gamma-rays based on Compton scatter could provide in principle high resolution and high sensitivity, thus becoming an advantageous method for the imaging of radioisotopes of clinical interest. A small laboratory prototype of a Compton camera is being constructed in order to initiate studies aimed at assessing the feasibility of Compton imaging of positron emitters. The design of the camera is based on the use of a silicon collimator consisting of a stack of double-sided, AC-coupled microstrip detectors (area 6x6 cm sup 2 , 500 mu m thickness, 128 channels/side). Two APV6 chips are employed for signal readout on opposite planes of each detector. This work presents the first results on the noise performance of the silicon strip detectors. Measurements of the electrical characteristics of the detector are also reported. On the basis of the measured noise, an angular resolution of approximately 5 deg. is predicted for the Compton collimator.

  6. New Compton densitometer for measuring pulmonary edema

    Energy Technology Data Exchange (ETDEWEB)

    Loo, B.W.; Goulding, F.S.; Simon, D.S.

    1985-10-01

    Pulmonary edema is the pathological increase of extravascular lung water found most often in patients with congestive heart failure and other critically ill patients who suffer from intravenous fluid overload. A non-invasive lung density monitor that is accurate, easily portable, safe and inexpensive is needed for clinical evaluation of pulmonary edema. Other researchers who have employed Compton scattering techniques generally used systems of extended size and detectors with poor energy resolution. This has resulted in significant systematic biases from multiply-scattered photons and larger errors in counting statistics at a given radiation dose to the patient. We are proposing a patented approach in which only backscattered photons are measured with a high-resolution HPGe detector in a compact system geometry. By proper design and a unique data extraction scheme, effects of the variable chest wall on lung density measurements are minimized. Preliminary test results indicate that with a radioactive source of under 30 GBq, it should be possible to make an accurate lung density measurement in one minute, with a risk of radiation exposure to the patient a thousand times smaller than that from a typical chest x-ray. The ability to make safe, frequent lung density measurements could be very helpful for monitoring the course of P.E. at the hospital bedside or outpatient clinics, and for evaluating the efficacy of therapy in clinical research. 6 refs., 5 figs.

  7. Magnetic pair and Compton sectrometers

    International Nuclear Information System (INIS)

    Bartholomew, G.A.; Lee-Whiting, G.E.

    1979-01-01

    Most types of magnetic gamma-ray spectrometers are much less used than they were ten or fifteen years ago largely because of the increased use of solid-state detectors. The latter permit much greater rates of data accumulation and, in many cases, better resolutions than the former. Many of the best magnetic instruments have been discarded or dismantled. Pair and Compton spectrometers are no exception of this trend. Thus much of the material to be considered reviewed by the authors must be of an historical nature. Inclusion of a brief account of magnetic pair and Compton spectrometers may be useful, not only for historical completeness, but also to suggest circumstances in which these spectrometers may still have advantages. (Auth.)

  8. Compton profile of calcium fluoride

    International Nuclear Information System (INIS)

    Vijayakumar, R.; Rajasekaran, L.; Ramamurthy, N.; Shivaramu

    2003-01-01

    Full text: The Compton profile of polycrystalline calcium fluoride is measured using 661.6 keV γ- radiation from a 137 Cs source. The experimental data are compared with HF-LCAO model calculation computed using CRYSTAL98 program, Hartree-Fock free atom theoretical values and with the other available experimental data. Experimental results are found to be in good agreement with the HF-LCAO model calculations and in qualitative agreement with Hartree-Fock free atom theoretical values

  9. A portable Compton spectrometer for clinical X-ray beams in the energy range 20-150 keV

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, A.A. [Departamento de Fisica, Pontificia Universidade Catolica de Sao Paulo (PUC-SP), Rua Marques de Paranagua, 111-01303-050 Sao Paulo, SP (Brazil); Linke, A. [Instituto de Fisica-Universidade de Sao Paulo, Rua do Matao, 187-Travessa R-05508-900 Sao Paulo, SP (Brazil); Yoshimura, E.M., E-mail: e.yoshimura@dfn.if.usp.b [Instituto de Fisica-Universidade de Sao Paulo, Rua do Matao, 187-Travessa R-05508-900 Sao Paulo, SP (Brazil); Terini, R.A., E-mail: rterini@pucsp.b [Departamento de Fisica, Pontificia Universidade Catolica de Sao Paulo (PUC-SP), Rua Marques de Paranagua, 111-01303-050 Sao Paulo, SP (Brazil); Instituto de Eletrotecnica e Energia-Universidade de Sao Paulo, Av. Prof. Luciano Gualberto, 1289-05508-900 Sao Paulo, SP (Brazil); Herdade, S.B., E-mail: sherdade@iee.usp.b [Instituto de Fisica-Universidade de Sao Paulo, Rua do Matao, 187-Travessa R-05508-900 Sao Paulo, SP (Brazil); Instituto de Eletrotecnica e Energia-Universidade de Sao Paulo, Av. Prof. Luciano Gualberto, 1289-05508-900 Sao Paulo, SP (Brazil)

    2011-02-15

    Primary beam spectra were obtained for an X-ray industrial equipment (40-150 kV), and for a clinical mammography apparatus (25-35 kV) from beams scattered at angles close to 90{sup o}, measured with a CdTe Compton spectrometer. Actual scattering angles were determined from the Compton energy shift of characteristic X-rays or spectra end-point energy. Evaluated contribution of coherent scattering amounts to more than 15% of fluence in mammographic beams. This technique can be used in clinical environments.

  10. A portable Compton spectrometer for clinical X-ray beams in the energy range 20-150 keV

    International Nuclear Information System (INIS)

    Vieira, A.A.; Linke, A.; Yoshimura, E.M.; Terini, R.A.; Herdade, S.B.

    2011-01-01

    Primary beam spectra were obtained for an X-ray industrial equipment (40-150 kV), and for a clinical mammography apparatus (25-35 kV) from beams scattered at angles close to 90 o , measured with a CdTe Compton spectrometer. Actual scattering angles were determined from the Compton energy shift of characteristic X-rays or spectra end-point energy. Evaluated contribution of coherent scattering amounts to more than 15% of fluence in mammographic beams. This technique can be used in clinical environments.

  11. Development of electron-tracking Compton imaging system with 30-μm SOI pixel sensor

    Science.gov (United States)

    Yoshihara, Y.; Shimazoe, K.; Mizumachi, Y.; Takahashi, H.; Kamada, K.; Takeda, A.; Tsuru, T.; Arai, Y.

    2017-01-01

    Compton imaging is a useful method to localize gamma sources without using mechanical collimators. In conventional Compton imaging, the incident directions of gamma rays are estimated in a cone for each event by analyzing the sequence of interactions of each gamma ray followed by Compton kinematics. Since the information of the ejection directions of the recoil electrons is lost, many artifacts in the shape of cone traces are generated, which reduces signal-to-noise ratio (SNR) and angular resolution. We have developed an advanced Compton imaging system with the capability of tracking recoil electrons by using a combination of a trigger-mode silicon-on-insulator (SOI) pixel detector and a GAGG detector. This system covers the 660-1330 keV energy range for localization of contamination nuclides such as 137Cs and 134Cs inside the Fukushima Daiichi Nuclear Power Plant in Japan. The ejection directions of recoil electrons caused by Compton scattering are detected on the micro-pixelated SOI detector, which can theoretically be used to determine the incident directions of the gamma rays in a line for each event and can reduce the appearance of artifacts. We obtained 2-D reconstructed images from the first iteration of the proposed system for 137Cs, and the SNR and angular resolution were enhanced compared with those of conventional Compton imaging systems.

  12. Performance of 20 Ci 137Cs γ-ray Compton spectrometer for the ...

    Indian Academy of Sciences (India)

    The in-house 137Cs spectrometer is very useful for the measurement of momentum densities of heavy materials. The performance of the machine is assessed using aluminum, terbium and mercury samples and the exper- imental data from comparable apparatus. Keywords. Compton scattering; electron momentum density; ...

  13. ILC beam energy measurement by means of laser Compton backscattering

    Energy Technology Data Exchange (ETDEWEB)

    Muchnoi, N. [Budker Inst. for Nuclear Physics, Novosibirsk (Russian Federation); Schreiber, H.J.; Viti, M. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany)

    2008-10-15

    A novel, non-invasive method of measuring the beam energy at the International Linear Collider is proposed. Laser light collides head-on with beam particles and either the energy of the Compton scattered electrons near the kinematic end-point is measured or the positions of the Compton backscattered {gamma}-rays, the edge electrons and the unscattered beam particles are recorded. A compact layout for the Compton spectrometer is suggested. It consists of a bending magnet and position sensitive detectors operating in a large radiation environment. Several options for high spatial resolution detectors are discussed. Simulation studies support the use of an infrared or green laser and quartz fiber detectors to monitor the backscattered photons and edge electrons. Employing a cavity monitor, the beam particle position downstream of the magnet can be recorded with submicrometer precision. Such a scheme provides a feasible and promising method to access the incident beam energy with precisions of 10{sup -4} or better on a bunch-to-bunch basis while the electron and positron beams are in collision. (orig.)

  14. INJECTION EFFICIENCY IN COMPTON RING NESTOR

    Directory of Open Access Journals (Sweden)

    P. I. Gladkikh

    2017-12-01

    Full Text Available NESTOR is the hard X-ray source that is under commissioning at NSC KIPT. NESTOR based on the Compton scattering of laser photons on relativistic electrons. The structure of the facility can be represented as the following components: a linear accelerator, a transport channel, a storage ring, and a laser-optical system. Electrons are stored in the storage ring for energy of 40-200 MeV. Inevitable alignment errors of magnetic elements are strongly effect on the beam dynamics in the storage ring. These errors lead to a shift of the equilibrium orbit relative to the ideal one. Significant shift of the equilibrium orbit could lead to loss of the beam on physical apertures. Transverse sizes of electron and laser beams are only few tens of microns at the interaction point. The shift of electron beam at the interaction point could greatly complicate the operation adjustment of storage ring without sufficient beam position diagnostic system. This article presents the simulation results of the efficiency of electron beam accumulation in the NESTOR storage ring. Also, this article is devoted to electron beam dynamics due to alignment errors of magnetic element in the ring.

  15. All-sky Compton imager

    Science.gov (United States)

    von Ballmoos, Peter; Boggs, Steven E.; Jean, Pierre; Zoglauer, Andreas

    2014-07-01

    The All-Sky Compton Imager (ASCI) is a mission concept for MeV Gamma-Ray astronomy. It consists of a compact array of cross-strip germanium detectors, shielded only by a plastic anticoicidence, and weighting less than 100 kg. Situated on a deployable structure at a distance of 10 m from the spacecraft orbiting at L2 or in a HEO, the ASCI not only avoids albedo- and spacecraft-induced background, but it benefits from a continuous all-sky exposure. The modest effective area is more than compensated by the 4 π field-of-view. Despite its small size, ASCI's γ-ray line sensitivity after its nominal lifetime of 3 years is ~ 10-6 ph cm-2 s-1 at 1 MeV for every γ-ray source in the sky. With its high spectral and 3-D spatial resolution, the ASCI will perform sensitive γray spectroscopy and polarimetry in the energy band 100 keV-10 MeV. The All-Sky Compton Imager is particularly well suited to the task of measuring the Cosmic Gamma-Ray Background - and simultaneously covering the wide range of science topics in gamma-ray astronomy.

  16. Parity assignments in 140Ce up to 7 MeV using Compton polarimetry

    International Nuclear Information System (INIS)

    Buessing, M. A.; Elvers, M.; Endres, J.; Hasper, J.; Zilges, A.; Fritzsche, M.; Lindenberg, K.; Mueller, S.; Savran, D.; Sonnabend, K.

    2008-01-01

    Parity quantum numbers of J=1 states up to 7 MeV in the region of the Pygmy Dipole Resonance in 140 Ce were determined model independently by combining the methods of Nuclear Resonance Fluorescence and Compton polarimetry. For the first time the well-established method of Compton polarimetry was applied at such high energies. The experiment was performed using a fourfold segmented HPGe clover detector for the detection of the scattered photons. For all investigated dipole transitions asymmetries are found which correspond to negative parity of the excited states

  17. Variation of Compton Profiles of the CO2 at different pressures

    Science.gov (United States)

    Gürol, Ali; Şakar, Erdem

    2017-04-01

    In this study, it has been measured the Compton Profile of the CO2 gas at different pressures by using a Compton Profile Spectrometer with an annular Am-241 radioactive source and a HPGe detector. CO2 gas molecules sealed in a gas chamber at different pressures. The gas pressure had been set by using an analog manometer before the measurements. The γ-rays emitted from source was incident into the gas from a hostaphan window. The detector recorded the scattered photons from molecules. To obtain correct Compton Profile values, the raw data were corrected for some effects; i.e. scattering from the gas chamber's walls, absorption effects of windows on gas chamber and detector, and multiple scattering corrections. A Matlab Code has been used for all calculations. The results clearly demonstrate the valance electronic structure of the materials is highly depending on the pressure. According to our experimental results, when the pressure in the gas chamber increase the Compton Profiles of valance electrons changes ˜ 8,0%.

  18. Analysis of the electronic structure of ZrO{sub 2} by Compton spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Mahammad, F. M.; Mahammed, S. F. [University of Tikrit 42, Department of Physics (Iraq); Kumar, R.; Vijay, Y. K.; Sharma, B. K. [University of Rajasthan, Department of Physics (India); Sharma, G., E-mail: gsphysics@gmail.com [University of Kota, Department of Pure and Applied Physics (India)

    2013-07-15

    The electronic structure of ZrO{sub 2} is studied using the Compton scattering technique. The first-ever Compton profile measurement on polycrystalline ZrO{sub 2} was obtained using 59.54 keV gamma-rays emanating from the {sup 241}Am radioisotope. To explain the experimental data, we compute theoretical Compton profile values using the method of linear combination of atomic orbitals in the framework of density functional theory. The correlation scheme proposed by Perdew-Burke-Ernzerhof and the exchange scheme of Becke are considered. The ionic-model-based calculations for a number of configurations, i.e., Zr{sup +x}(O{sup -x/2}){sub 2} (0 {<=} x {<=} 2), are also performed to estimate the charge transfer on compound formation, and the study supports transfer of 1.5 electrons from Zr to O atoms.

  19. Real space analysis of Compton profile of Heusler alloy Ni2TiAl

    Science.gov (United States)

    Sahariya, Jagrati; Mund, H. S.; Ahuja, B. L.

    2012-06-01

    Electron momentum density of Ni2TiAl alloy has been studied using Compton scattering technique. The experiment has been performed using 20 Ci 137Cs (661.65 keV) Compton spectrometer at an intermediate resolution of 0.34 a.u. To interpret the experimental data, we have calculated the Compton profiles using Hartree Fock and density functional theories within the frame work of linear combination of atomic orbitals (LCAO) method. The experimental data have been interpreted in term of autocorrelation function B(z) of the one electron wave function. The experimental B(z) function has been compared with the LCAO based theoretical B(z), to analyze the electronic and structural properties of Ni2TiAl.

  20. Resonant Compton cooling and annihilation line production in gamma-ray bursts

    Science.gov (United States)

    Preece, R. D.; Harding, A. K.

    1992-01-01

    Attention is given to a synchrotron self-Compton emission model for gamma-ray bursts which produces narrow annihilation features for a variety of field strengths, primary electron injection energies, and injection rates. In this model, primary electrons are injected and cooled by synchrotron emission in a strong, homogeneous magnetic field, resulting in a pair cascade. Multiple resonant scattering with cyclotron photons efficiently traps and cools pairs in the ground state to an average energy where the Compton energy loss rate is zero, which is in agreement with previous estimates of a Compton temperature. The particle distributions in the ground state are determined by numerically solving the Fokker-Planck equation in the steady state. In the case of isotropic injection of primary electrons, a significant narrow-line feature appears in the overall emission. In the case of beamed injection, the annihilation line is broadened to the extent that it would not be observable.

  1. Development of a Compton Camera for Online Range Monitoring of Laser-Accelerated Proton Beams via Prompt-Gamma Detection

    Directory of Open Access Journals (Sweden)

    Thirolf P.G.

    2014-03-01

    Full Text Available Presently large efforts are conducted in Munich towards the development of proton beams for bio-medical applications, generated via the technique of particle acceleration from high-power, short-pulse lasers. While so far mostly offline diagnostics tools are used in this context, we aim at developing a reliable and accurate online range monitoring technique, based on the position-sensitive detection of prompt γ rays emitted from nuclear reactions between the proton beam and the biological sample. For this purpose, we develop a Compton camera, designed to be able to track not only the Compton scattering of the primary photon, but also to detect the secondary Compton electron, thus reducing the Compton cone to an arc segment and by this increasing the source reconstruction efficiency. Design specifications and the status of the protype system are discussed.

  2. Fast cooling of bunches in compton storage rings*

    CERN Document Server

    Bulyak, E; Zimmermann, F

    2011-01-01

    We propose an enhancement of laser radiative cooling by utilizing laser pulses of small spatial and temporal dimensions, which interact only with a fraction of an electron bunch circulating in a storage ring. We studied the dynamics of such electron bunch when laser photons scatter off the electrons at a collision point placed in a section with nonzero dispersion. In this case of ‘asymmetric cooling’, the stationary energy spread is much smaller than under conditions of regular scattering where the laser spot size is larger than the electron beam; and the synchrotron oscillations are damped faster. Coherent oscillations of large amplitude may be damped within one synchrotron period, so that this method can support the rapid successive injection of many bunches in longitudinal phase space for stacking purposes. Results of extensive simulations are presented for the performance optimization of Compton gamma-ray sources and damping rings.

  3. Electromagnetic energies of nuclei and the nuclear Compton amplitude

    International Nuclear Information System (INIS)

    Friar, J.L.

    1976-01-01

    The electromagnetic energy of a nucleus is derived in perturbation theory, which relates this quantity to the amplitude for the forward scattering of virtual photons on a nucleus (nuclear Compton amplitude). Through the use of the gauge invariance of this amplitude, the energy is separated into Coulomb and transverse components. Our formalism, although basically nonrelativistic, admits corrections of order (v/c) 2 to the nuclear charge operator. The energy is further separated into one-body terms, related to the n--p mass difference, and two-body terms which lead to the Breit interaction and the nuclear Lamb shift. These results are then related to electron scattering sum rules in the manner of Cottingham. Mesonic contributions to the electromagnetic energy are also discussed

  4. Development of a compact scintillator-based high-resolution Compton camera for molecular imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kishimoto, A., E-mail: daphne3h-aya@ruri.waseda.jp [Research Institute for Science and Engineering, Waseda University, 3-4-1 Ohkubo, Shinjuku, Tokyo (Japan); Kataoka, J.; Koide, A.; Sueoka, K.; Iwamoto, Y.; Taya, T. [Research Institute for Science and Engineering, Waseda University, 3-4-1 Ohkubo, Shinjuku, Tokyo (Japan); Ohsuka, S. [Central Research Laboratory, Hamamatsu Photonics K.K., 5000 Hirakuchi, Hamakita-ku, Hamamatsu, Shizuoka (Japan)

    2017-02-11

    The Compton camera, which shows gamma-ray distribution utilizing the kinematics of Compton scattering, is a promising detector capable of imaging across a wide range of energy. In this study, we aim to construct a small-animal molecular imaging system in a wide energy range by using the Compton camera. We developed a compact medical Compton camera based on a Ce-doped Gd{sub 3}Al{sub 2}Ga{sub 3}O{sub 12} (Ce:GAGG) scintillator and multi-pixel photon counter (MPPC). A basic performance confirmed that for 662 keV, the typical energy resolution was 7.4 % (FWHM) and the angular resolution was 4.5° (FWHM). We then used the medical Compton camera to conduct imaging experiments based on a 3-D imaging reconstruction algorithm using the multi-angle data acquisition method. The result confirmed that for a {sup 137}Cs point source at a distance of 4 cm, the image had a spatial resolution of 3.1 mm (FWHM). Furthermore, we succeeded in producing 3-D multi-color image of different simultaneous energy sources ({sup 22}Na [511 keV], {sup 137}Cs [662 keV], and {sup 54}Mn [834 keV]).

  5. Neutral pion electroproduction and virtual Compton scattering on proton with four-momentum transfer squared Q{sup 2} = 1 GeV{sup 2}. Measurement of cross-sections and of generalized polarizabilities; Electroproduction de photons et de pions sur le proton au quadrimoment de transfert Q{sup 2} = 1.0 GeV{sup 2}. Mesure des sections efficaces et extraction des polarisabilites generalisees

    Energy Technology Data Exchange (ETDEWEB)

    Laveissiere, G

    2001-11-01

    In hadronic physics, the nucleon structure and the quarks confinement are still topical issues. The neutral pion electroproduction and virtual Compton scattering (VCS) reactions allow us to access new observables that describe this structure. This work is focussed on the VCS experiment performed at Jefferson Lab in 1998. The 4 GeV electron beam is scattered off a cryogenic hydrogen target, and the scattered electron and recoiled proton are detected in coincidence in the twin hall A spectrometers. The photon (pion) is reconstructed using a missing particle technique. The data analysis allowed to extract the cross sections relative to both process at four-momentum transfer squared Q{sup 2} = 1 GeV{sup 2}. The VCS cross section has been extracted for the first time in the proton resonance region (W between 1.O and 2.0 GeV) through the photon electroproduction reaction. Around the pion-production threshold up to the Delta(1232) resonance region, these results lead to the measurement of the generalized polarizabilities, that describe the proton structure in the same way as the elastic form factors. Moreover, the neutral pion electroproduction cross section measurement in the resonance region has brought new constraints on the existing phenomenological models. (author)

  6. CsI Calorimeter for a Compton-Pair Telescope

    Science.gov (United States)

    Grove, Eric J.

    We propose to build and test a hodoscopic CsI(Tl) scintillating-crystal calorimeter for a medium-energy γ-ray Compton and pair telescope. The design and technical approach for this calorimeter relies deeply on heritage from the Fermi LAT CsI Calorimeter, but it dramatically improves the low-energy performance of that design by reading out the scintillation light with silicon photomultipliers (SiPMs), making the technology developed for Fermi applicable in the Compton regime. While such a hodoscopic calorimeter is useful for an entire class of medium-energy γ-ray telescope designs, we propose to build it explicitly to support beam tests and balloon flight of the Proto-ComPair telescope, the development and construction of which was funded in a four-year APRA program beginning in 2015 ("ComPair: Steps to a Medium Energy γ-ray Mission" with PI J. McEnery of GSFC). That award did not include funding for its CsI calorimeter subsystem, and this proposal is intended to cover that gap. ComPair is a MIDEX-class instrument concept to perform a high-sensitivity survey of the γ-ray sky from 0.5 MeV to 500 MeV. ComPair is designed to provide a dramatic increase in sensitivity relative to previous instruments in this energy range (predominantly INTEGRAL/SPI and Compton COMPTEL), with the same transformative sensitivity increase - and corresponding scientific return- that the Fermi Large Area Telescope provided relative to Compton EGRET. To enable transformative science over a broad range of MeV energies and with a wide field of view, ComPair is a combined Compton telescope and pair telescope employing a silicon-strip tracker (for Compton scattering and pair conversion and tracking) and a solid-state CdZnTe calorimeter (for Compton absorption) and CsI calorimeter (for pair calorimetry), surrounded by a plastic scintillator anti-coincidence detector. Under the current proposal, we will complete the detailed design, assembly, and test of the CsI calorimeter for the risk

  7. Subset construction strategy for ordered-subset expectation-maximization reconstruction in compton camera imaging system

    International Nuclear Information System (INIS)

    Kim, Soo Mee; Lee, Jae Sung; Lee, Soo Jin

    2007-01-01

    In this study, the expectation maximization (EM) and ordered subset EM (OSEM) reconstruction algorithms have been applied to the Compton projection data. For OSEM, we propose the several methods for constructing subsets and compare the impact of the each method on the reconstructed images to choose the proper subset construction method. A Compton camera was consisted of three pairs of scatterer and absorber detectors which were parallel to each other. The detector pairs were positioned along the x-, y-, and z-axes at the radial offset of 10 em. The 3-directional projection data of 5-cylinder software phantom (64x64x64 array, 1.56mm) was obtained from a Compton projector. In this study, we used the iterative reconstruction algorithms such as EM and OSEM. For application of OSEM algorithm to the Compton camera, we proposed three strategies for constructing the exclusive subsets; scattering angle-based subsets (OSEM-SA), detector-position-based subsets (OSEM-DP), and both scattering angle- and detector-position-based subsets (OSEM-AP). The OSEM with 16, 64 and 128 subsets were performed through 16, 4, and 2 iterations, respectively. The OSEM with 16 subsets and 4 iterations was equivalent to the EM with 64 iterations, but the computation time was approximately reduced by 14 times. All the three schemes for choosing the subsets in OSEM algorithm yielded similar results in computation time, but the percent error for OSEM-SA was slightly larger than others. No significant change of percent error as the subset number increased up to 128 was observed. The simulation results showed that the EM reconstruction algorithm is applicable to the Compton camera data with sufficient counting statistics. OSEM significantly improved the computational efficiency and maintained the image quality of the standard EM reconstruction. The OSEM algorithm which included subsets on the detection positions (OSEM-DP and OSEM-AP) provided slightly better results than OSEM-SA

  8. X-ray dosimetry in mammography for W/Mo and Mo/Mo combinations utilizing Compton spectrometry;Dosimetria de raios X em mamografia para combinacao W/Mo e Mo/Mo utilizando espectrometria Compton

    Energy Technology Data Exchange (ETDEWEB)

    Almeida Junior, Jose N. [Pontificia Univ. Catolica de Sao Paulo (PUC/SP), SP (Brazil). Curso de Fisica; Terini, Ricardo A. [Pontificia Univ. Catolica de Sao Paulo (DF/PUC/SP), SP (Brazil). Dept. de Fisica; Herdade, Silvio B.; Furquim, Tania A.C. [Universidade de Sao Paulo (IEE/USP), SP (Brazil). Inst. de Eletrotecnica e Energia

    2009-07-01

    Mean Glandular Dose (MGD) cannot be measured directly in mammography equipment. Therefore, methods based on Compton spectrometry are alternatives to evaluate dose distributions in a standard breast phantom, as well as mean glandular dose. In this work, a CdTe detector was used for the spectrometry measurements of radiation scattered by compton effect, at nearly 90, by a PMMA cylinder. For this, the reconstruction of primary beam spectra from the scattered ones has been made using Klein-Nishina theory and Compton formalism, followed by a determination of incident air kerma, absorbed dose values in the breast phantom and, finally, MGD. Incident and attenuated X-ray spectra and depth-dose distributions in a BR-12 phantom have been determined and are presented for the mammography range (28 to 35kV), showing good agreement with previous literature data, obtained with TLD. (author)

  9. Compton spectrometry applied to dose measurement in mammography for W/Mo and Mo/Mo combinations; Espectrometria Compton aplicada a medicao de doses em mamografia para combinacoes W/Mo e Mo/Mo

    Energy Technology Data Exchange (ETDEWEB)

    Almeida Junior, Jose N. [Pontificia Univ. Catolica de Sao Paulo (PUC/SP), SP (Brazil); Terini, Ricardo A., E-mail: rterini@pucusp.b [Pontificia Univ. Catolica de Sao Paulo (PUC/SP), SP (Brazil). Dept. de Fisica; Herdade, Silvio B.; Furquim, Tania A.C. [Universidade de Sao Paulo (IEE/USP), SP (Brazil). Inst. de Eletrotecnica e Energia

    2010-06-15

    Mean Glandular Dose (MGD) cannot be measured directly in mammography equipment. Therefore, methods based on Compton spectrometry are alternatives to evaluate dose distributions in a standard breast phantom, as well as mean glandular dose. In this work, a CdTe detector was used for the spectrometry measurements of radiation scattered by Compton Effect, at nearly 90 deg, by a PMMA cylinder inserted between the breast phantom plates. For this, the reconstruction of primary beam spectra from the scattered ones has been made using Klein-Nishina theory and Compton formalism, followed by a determination of incident air kerma, absorbed dose values in the breast phantom and, finally, MGD. Incident and attenuated X-ray spectra and depth-dose distributions in a BR-12 phantom have been determined and are presented for the mammography range (28 to 35kV). Results have shown good agreement with previous literature data, obtained with TLD. (author)

  10. X-ray dosimetry in mammography for W/Mo and Mo/Mo combinations utilizing Compton spectrometry

    International Nuclear Information System (INIS)

    Almeida Junior, Jose N.; Terini, Ricardo A.; Herdade, Silvio B.; Furquim, Tania A.C.

    2009-01-01

    Mean Glandular Dose (MGD) cannot be measured directly in mammography equipment. Therefore, methods based on Compton spectrometry are alternatives to evaluate dose distributions in a standard breast phantom, as well as mean glandular dose. In this work, a CdTe detector was used for the spectrometry measurements of radiation scattered by compton effect, at nearly 90, by a PMMA cylinder. For this, the reconstruction of primary beam spectra from the scattered ones has been made using Klein-Nishina theory and Compton formalism, followed by a determination of incident air kerma, absorbed dose values in the breast phantom and, finally, MGD. Incident and attenuated X-ray spectra and depth-dose distributions in a BR-12 phantom have been determined and are presented for the mammography range (28 to 35kV), showing good agreement with previous literature data, obtained with TLD. (author)

  11. Determination of total iron in iron ore by x-ray fluorescence analysis using the Compton effect: comparison with others analytical techniques

    International Nuclear Information System (INIS)

    Castilho, M.V. de; Oliveira, R.C.

    1991-01-01

    Total iron in iron ores is determines by X-ray fluorescence analysis method using the compton effect. The Bragg angle is determined for compton no-coherent scattering related to K alpha of Rhodium. This measurement procedure can be used for best fitting of analytical results in X-ray fluorescence, when compared with others methods used for results corrections. (M.V.M.)

  12. Production of X-rays by inverse Compton effect

    International Nuclear Information System (INIS)

    Mainardi, R.T.

    2005-01-01

    X-rays and gamma rays of high energy values can be produced by the scattering of low energy photons with high energy electrons, being this a process controlled by the Compton scattering. If a laser beam is used, the x-ray beam inherits the properties of intensity, monochromaticity and collimation from the laser. In this work we analyze the generation of intense x-ray beams of energies between 10 and 100 KeV to be used in a wide range of applications where a high intensity and high degrees of monochromaticity and polarization are important properties to improve image reduce doses and improve radiation treatments. To this purpose we evaluated, using relativistic kinematics the scattered beam properties in terms of the scattering angle. This arrangement is being considered in several worldwide laboratories as an alternative to synchrotron radiation and is referred to as 'table top synchrotron radiation', since it cost of installation is orders of magnitude smaller than a 'synchrotron radiation source'. The radiation beam might exhibit non-linear properties in its interaction with matter, in a similar way as a laser beam and we will investigate how to calibrate and evaluate TLD dosemeters properties, both in low and high intensity fields either mono or polyenergetic in wide spectral energy ranges. (Author)

  13. Luminosity optimization schemes in Compton experiments based on Fabry-Perot optical resonators

    Directory of Open Access Journals (Sweden)

    Alessandro Variola

    2011-03-01

    Full Text Available The luminosity of Compton x-ray and γ sources depends on the average current in electron bunches, the energy of the laser pulses, and the geometry of the particle bunch to laser pulse collisions. To obtain high power photon pulses, these can be stacked in a passive optical resonator (Fabry-Perot cavity especially when a high average flux is required. But, in this case, owing to the presence of the optical cavity mirrors, the electron bunches have to collide at an angle with the laser pulses with a consequent luminosity decrease. In this article a crab-crossing scheme is proposed for Compton sources, based on a laser amplified in a Fabry-Perot resonator, to eliminate the luminosity losses given by the crossing angle, taking into account that in laser-electron collisions only the electron bunches can be tilted at the collision point. We report the analytical study on the crab-crossing scheme for Compton gamma sources. The analytical expression for the total yield of photons generated in Compton sources with the crab-crossing scheme of collision is derived. The optimal collision angle of the bunch was found to be equal to half of the collision angle. At this crabbing angle, the maximal yield of scattered off laser photons is attained thanks to the maximization, in the collision process, of the time spent by the laser pulse in the electron bunch. Estimations for some Compton source projects are presented. Furthermore, some schemes of the optical cavities configuration are analyzed and the luminosity calculated. As illustrated, the four-mirror two- or three-dimensional scheme is the most appropriate for Compton sources.

  14. Probing the structure of the virtual photon in the deep inelastic Compton process at the DESY HERA collider

    International Nuclear Information System (INIS)

    Krawczyk, M.; Zembrzuski, A.

    1998-01-01

    The sensitivity of deep inelastic Compton (DIC) scattering at DESY HERA to the structure of the virtual photon is discussed. It is demonstrated that the gluonic content of the virtual photon can be pinned down by measuring the photons with p T ∼5 GeV in the proton direction. copyright 1997 The American Physical Society

  15. Production of X-rays by inverse Compton effect; Produccion de rayos X por efecto Compton inverso

    Energy Technology Data Exchange (ETDEWEB)

    Mainardi, R.T. [Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, 5000 Cordoba (Argentina)

    2005-07-01

    X-rays and gamma rays of high energy values can be produced by the scattering of low energy photons with high energy electrons, being this a process controlled by the Compton scattering. If a laser beam is used, the x-ray beam inherits the properties of intensity, monochromaticity and collimation from the laser. In this work we analyze the generation of intense x-ray beams of energies between 10 and 100 KeV to be used in a wide range of applications where a high intensity and high degrees of monochromaticity and polarization are important properties to improve image reduce doses and improve radiation treatments. To this purpose we evaluated, using relativistic kinematics the scattered beam properties in terms of the scattering angle. This arrangement is being considered in several worldwide laboratories as an alternative to synchrotron radiation and is referred to as 'table top synchrotron radiation', since it cost of installation is orders of magnitude smaller than a 'synchrotron radiation source'. The radiation beam might exhibit non-linear properties in its interaction with matter, in a similar way as a laser beam and we will investigate how to calibrate and evaluate TLD dosemeters properties, both in low and high intensity fields either mono or polyenergetic in wide spectral energy ranges. (Author)

  16. A Compton camera prototype for prompt gamma medical imaging

    Directory of Open Access Journals (Sweden)

    Thirolf P.G.

    2016-01-01

    Full Text Available Compton camera prototype for a position-sensitive detection of prompt γ rays from proton-induced nuclear reactions is being developed in Garching. The detector system allows to track the Comptonscattered electrons. The camera consists of a monolithic LaBr3:Ce scintillation absorber crystal, read out by a multi-anode PMT, preceded by a stacked array of 6 double-sided silicon strip detectors acting as scatterers. The LaBr3:Ce crystal has been characterized with radioactive sources. Online commissioning measurements were performed with a pulsed deuteron beam at the Garching Tandem accelerator and with a clinical proton beam at the OncoRay facility in Dresden. The determination of the interaction point of the photons in the monolithic crystal was investigated.

  17. Generation of laser Compton gamma-rays using Compact ERL

    International Nuclear Information System (INIS)

    Shizuma, Toshiyuki; Hajima, Ryoichi; Nagai, Ryoji; Hayakawa, Takehito; Mori, Michiaki; Seya, Michio

    2015-01-01

    Nondestructive isotope-specific assay system using nuclear resonance fluorescence has been developed at JAEA. In this system, intense, mono-energetic laser Compton scattering (LCS) gamma-rays are generated by combining an energy recovery linac (ERL) and laser enhancement cavity. As technical development for such an intense gamma-ray source, we demonstrated generation of LCS gamma-rays using Compact ERL (supported by the Ministry of Education, Culture, Sports, Science and Technology) developed in collaboration with KEK. We also measured X-ray fluorescence for elements near iron region by using mono-energetic LCS gamma-rays. In this presentation, we will show results of the experiment and future plan. (author)

  18. Virtual Compton scattering off the proton at Jefferson Lab (experiment E93050): preliminary results of the cross-sections of the reaction (ep{yields}ep{gamma}) in order to find out the generalized polarizabilities (GPs) of the proton at Q{sup 2} = 1.9 GeV{sup 2}; Diffusion compton virtuelle a jefferson lab (experience E93050): resultat preliminaire des sections efficaces (ep{yields}ep{gamma}) en vue d'extraire les polarisabilites generalisees du proton a Q{sup 2} = 1.9 GEV{sup 2}

    Energy Technology Data Exchange (ETDEWEB)

    Jaminion, St

    2000-12-01

    Virtual Compton Scattering off the proton ({gamma}{sup *}p {yields} {gamma}p) at low energy is accessible via the reaction (ep {yields} ep{gamma}), and contains 6 new observables: Generalized Polarizabilities (GPs). Their extraction needs the measurement of absolute five fold differential cross sections for photon electroproduction off the proton. The determination of GPs will put new constraints on models of nucleon structure in the non-perturbative Quantum Chromodynamics region. Following the Mainz experiment realized at four momentum transfer Q{sup 2} = 0.33 GeV{sup 2}, the E93050 experiment which was performed in the Hall A of Jefferson Lab during march-april 1998, will allow the measurement of combinations of generalized polarizabilities at Q{sup 2}=1 and 1.9 GeV{sup 2}. The final electron and proton were detected in coincidence in the Hall A high resolution spectrometers. The final photon is reconstructed like a missing particle, and all its variables can be determined. We had to optimize optics tensor of each spectrometer in order to have the best reconstruction at vertex point. We created an acceptance function, which is included in the software simulating solid angle. We determined different cuts to substract our background dominating (ep {yields} ep{gamma}) reaction. This work allows to carry out our first photon electro-production cross section measurement at Q{sup 2}=1.9 GeV{sup 2}. The results seem to indicate a measurable effect of generalized polarizabilities, which remains however to be confirmed. (author)

  19. Electronic structure and Compton profiles of tungsten

    International Nuclear Information System (INIS)

    Lal Ahuja, Babu; Rathor, Ashish; Sharma, Vinit; Sharma, Yamini; Ramniklal Jani, Ashvin; Sharma, Balkrishna

    2008-01-01

    The energy bands, density of states and Compton profiles of tungsten have been computed using band structure methods, namely the spin-polarized relativistic Korringa-Kohn-Rostoker (SPR-KKR) approach as well as the linear combination of atomic orbitals with Hartree-Fock scheme and density functional theory. The full potential linearized augmented plane wave scheme to calculate these properties and the Fermi surface topology(except the momentum densities) have also been used to analyze the theoretical data on the electron momentum densities. The directional Compton profiles have been measured using a 100 mCi 241 Am Compton spectrometer. From the comparison, the measured anisotropies are found to be in good agreement with the SPR-KKR calculations. The band structure calculations are also compared with the available data. (orig.)

  20. Monte Carlo simulation of virtual compton scattering at MAMI

    International Nuclear Information System (INIS)

    D'Hose, N.; Ducret, J.E.; Gousset, TH.; Guichon, P.A.M.; Kerhoas, S.; Lhuillier, D.; Marchand, C.; Marchand, D.; Martino, J.; Mougey, J.; Roche, J.; Vanderhaeghen, M.; Vernin, P.; Bohm, H.; Distler, M.; Edelhoff, R.; Friedrich, J.M.; Geiges, R.; Jennewein, P.; Kahrau, M.; Korn, M.; Kramer, H.; Krygier, K.W.; Kunde, V.; Liesenfeld, A.; Merkel, H.; Merle, K.; Neuhausen, R.; Pospischil, TH.; Rosner, G.; Sauer, P.; Schmieden, H.; Schardt, S.; Tamas, G.; Wagner, A.; Walcher, TH.; Wolf, S.; Hyde-Wright, CH.; Boeglin, W.U.; Van de Wiele, J.

    1996-01-01

    The Monte Carlo simulation developed specially for the VCS experiments taking place at MAMI in fully described. This simulation can generate events according to the Bethe-Heitler + Born cross section behaviour and takes into account resolution deteriorating effects. It is used to determine solid angles for the various experimental settings. (authors)

  1. Stimulated ion Compton scattering instability of whistlers in plasmas

    International Nuclear Information System (INIS)

    Shukla, P. K.; Shukla, Nitin; Stenflo, L.

    2006-01-01

    The nonlinear interactions between magnetic field-aligned broadband whistler wave packets (hereafter referred to as whistlerons) and ion quasimodes in magnetized plasmas are considered. By treating the whistlerons as quasiparticles, their nonlinear propagation in a slowly varying medium supported by ion quasimode density perturbations is studied. A nonlinear dispersion relation within the framework of the wave-kinetic (for the whistlerons) and Vlasov (for the ion quasimodes) descriptions is derived. The dispersion relation admits a kinetic modulational instability. The growth rate of the latter is presented. The present result can improve our understanding of the nonlinear propagation of incoherent whistlers, which have been frequently observed in the Earth's magnetosphere as well as in laboratory plasmas

  2. Deeply virtual Compton scattering in a relativistic quark model

    Energy Technology Data Exchange (ETDEWEB)

    Spitzenberg, T.

    2007-09-15

    This thesis is mainly concerned with a model calculation for generalized parton distributions (GPDs). We calculate vectorial- and axial GPDs for the N{yields}N and N{yields}{delta} transition in the framework of a light front quark model. This requires the elaboration of a connection between transition amplitudes and GPDs. We provide the first quark model calculations for N{yields}{delta} GPDs. The examination of transition amplitudes leads to various model independent consistency relations. These relations are not exactly obeyed by our model calculation since the use of the impulse approximation in the light front quark model leads to a violation of Poincare covariance. We explore the impact of this covariance breaking on the GPDs and form factors which we determine in our model calculation and find large effects. The reference frame dependence of our results which originates from the breaking of Poincare covariance can be eliminated by introducing spurious covariants. We extend this formalism in order to obtain frame independent results from our transition amplitudes. (orig.)

  3. Experiments in Special Relativity Using Compton Scattering of Gamma Rays.

    Science.gov (United States)

    Egelstaff, P. A.; And Others

    1981-01-01

    Some simple undergraduate laboratory experiments are described, which verify the energy-momentum relationship of special relativity. These experiments have been designed either to be used as classroom demonstrations or to be carried out by second-year students. (Author/JN)

  4. Constraint on Parameters of Inverse Compton Scattering Model for ...

    Indian Academy of Sciences (India)

    ,28o,35o. 3. Results. Figure 1 presents the best fit regions at 68% confidence level for γ0 and ξ, which depend on α. The main results are summarized as follows: • γ0 and ξ are larger than ∼6000 and ∼90, respectively. The allowed ranges ...

  5. Relativistic inverse Compton scattering of photons from the early universe.

    Science.gov (United States)

    Malu, Siddharth; Datta, Abhirup; Colafrancesco, Sergio; Marchegiani, Paolo; Subrahmanyan, Ravi; Narasimha, D; Wieringa, Mark H

    2017-12-05

    Electrons at relativistic speeds, diffusing in magnetic fields, cause copious emission at radio frequencies in both clusters of galaxies and radio galaxies through non-thermal radiation emission called synchrotron. However, the total power radiated through this mechanism is ill constrained, as the lower limit of the electron energy distribution, or low-energy cutoffs, for radio emission in galaxy clusters and radio galaxies, have not yet been determined. This lower limit, parametrized by the lower limit of the electron momentum - p min - is critical for estimating the total energetics of non-thermal electrons produced by cluster mergers or injected by radio galaxy jets, which impacts the formation of large-scale structure in the universe, as well as the evolution of local structures inside galaxy clusters. The total pressure due to the relativistic, non-thermal population of electrons can be measured using the Sunyaev-Zel'dovich Effect, and is critically dependent on p min , making the measurement of this non-thermal pressure a promising technique to estimate the electron low-energy cutoff. We present here the first unambiguous detection of this Sunyaev-Zel'dovich Effect for a non-thermal population of electrons in a radio galaxy jet/lobe, located at a significant distance away from the center of the Bullet cluster of galaxies.

  6. A study on CZT and scintillator based micro-PETs with compton tracing technology

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Chang Yeon; Lee, Won Ho [Dept. of Bio-convergence Engineering, Korea University Graduate School, Seoul (Korea, Republic of)

    2015-10-15

    In this research, the performance of micro-PET with CZT semiconductor was compared with those with LYSO and LGSO scintillators based on detection efficiency and the quality of reconstructed images. Compton and conventional PET system with three detector materials were evaluated and compared with each other. The conventional PETs widely used in clinics generally consisted of lutetium series scintillators such as LSO, LYSO or LGSO. These scintillators have high atomic number and density, and hence, their detection efficiencies are very high. Even though the atomic number and density of CZT were relatively lower than those of scintillators resulting in less detection efficiency, the pixellized CZTs showed much higher position resolution than conventional detectors. Moreover, pixellized CZT can precisely track the interaction position inside detectors, in which Compton scattering as well as photoelectric events can be effective interaction, and hence, the detection efficiency improves significantly. For all material, the efficiency of Compton PETs was always higher than that of conventional PETs, and hence the image quality was also improved by using Compton PET technology.

  7. Compton profiles and electronic structure of monoclinic zinc and cadmium tungstates

    Science.gov (United States)

    Meena, B. S.; Heda, N. L.; Mund, H. S.; Ahuja, B. L.

    2015-12-01

    We report the first ever Compton scattering study of ZnWO4 and CdWO4 using 20 Ci 137Cs Compton spectrometer at momentum resolution of 0.34 a.u. To compare the experimental Compton profiles, we have also deduced the momentum densities using density functional theory (DFT) within linear combination of atomic orbitals (LCAO) methods. It is seen that the experimental Compton profiles of both the tungstates give a better agreement with LCAO-DFT calculations within generalized gradient approximation (GGA) employing Perdew-Becke-Ernzerhof (PBE) exchange and correlation energies than other approximations included in the present work. Further, energy bands, density of states (DOS) and band gaps have also been calculated using LCAO-DFT-GGA-PBE scheme and full potential linearized augmented plane wave method. Both the computational schemes show a semiconducting nature of both the tungstates, with a direct band gap at Y point of Brillouin zone. Further, a relative nature of bonding on equal-valence-electron-density scale shows more covalent character in ZnWO4 than CdWO4 which reconciles with the conclusions drawn using integrated DOS and Mulliken's population data.

  8. Standardization of Compton suppression gamma spectrometry system for the measurement of 129I in environmental samples

    International Nuclear Information System (INIS)

    Baburajan, A.; Sudheendran, V.; Dalvi, Sushant S.; Ravi, P.M.; Tripathi, R.M.

    2014-01-01

    This paper presents the results of standardization of a Compton Suppression Gamma spectrometry system for the determination of 129 I in various environmental samples in the pathways of Air - grass - milk (thyroid) - Man. The Compton Suppression System consists of an HPGe detector surrounded by an assembly of NaI(Tl) detectors, used to reduce the contribution of scattered gamma rays in the gamma spectrum that originate within the HPGe detector. A Compton suppression system consisting of N-type HPGe detector, 50% relative efficiency having low window thickness of about 0.3μm of Boron, and NaI(TI) detector as Compton shield was commissioned at ESL, Tarapur and various performance parameters were evaluated and documented. Being a reverse electrode HPGe system with low window thickness it can be used for the detection of low energy gamma lines from 3.0 keV to >10 MeV (Ortec). Hence, it is proposed to use the system for the determination of 129 I in environmental samples. The paper deals with the standardization of the system for efficiency and Minimum Detectable Activity (MDA) for various sample geometries in the detection of low level 129 I in various pathways of its exposure

  9. A likely inverse-Compton emission from the Type IIb SN 2013df

    Science.gov (United States)

    Li, K. L.; Kong, A. K. H.

    2016-08-01

    The inverse-Compton X-ray emission model for supernovae has been well established to explain the X-ray properties of many supernovae for over 30 years. However, no observational case has yet been found to connect the X-rays with the optical lights as they should be. Here, we report the discovery of a hard X-ray source that is associated with a Type II-b supernova. Simultaneous emission enhancements have been found in both the X-ray and optical light curves twenty days after the supernova explosion. While the enhanced X-rays are likely dominated by inverse-Compton scatterings of the supernova’s lights from the Type II-b secondary peak, we propose a scenario of a high-speed supernova ejecta colliding with a low-density pre-supernova stellar wind that produces an optically thin and high-temperature electron gas for the Comptonization. The inferred stellar wind mass-loss rate is consistent with that of the supernova progenitor candidate as a yellow supergiant detected by the Hubble Space Telescope, providing an independent proof for the progenitor. This is also new evidence of the inverse-Compton emission during the early phase of a supernova.

  10. Optimization of Compton Source Performance through Electron Beam Shaping

    Energy Technology Data Exchange (ETDEWEB)

    Malyzhenkov, Alexander [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Yampolsky, Nikolai [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-26

    We investigate a novel scheme for significantly increasing the brightness of x-ray light sources based on inverse Compton scattering (ICS) - scattering laser pulses off relativistic electron beams. The brightness of ICS sources is limited by the electron beam quality since electrons traveling at different angles, and/or having different energies, produce photons with different energies. Therefore, the spectral brightness of the source is defined by the 6d electron phase space shape and size, as well as laser beam parameters. The peak brightness of the ICS source can be maximized then if the electron phase space is transformed in a way so that all electrons scatter off the x-ray photons of same frequency in the same direction, arriving to the observer at the same time. We describe the x-ray photon beam quality through the Wigner function (6d photon phase space distribution) and derive it for the ICS source when the electron and laser rms matrices are arbitrary.

  11. Intra- and intermolecular effects on the Compton profile of the ionic liquid 1,3-dimethylimidazolium chloride

    Energy Technology Data Exchange (ETDEWEB)

    Koskelo, J., E-mail: jaakko.koskelo@helsinki.fi; Juurinen, I.; Ruotsalainen, K. O.; Lehtola, S.; Galambosi, S.; Hämäläinen, K.; Huotari, S.; Hakala, M., E-mail: mikko.o.hakala@helsinki.fi [Department of Physics, University of Helsinki, P.O. Box 64, FI-00014 Helsinki (Finland); McGrath, M. J. [Laboratoire des Sciences du Climat et de l’Environnement, CEA-Orme des Merisiers, F-91191 Gif-sur-Yvette CEDEX (France); Kuo, I-F. [Physical and Life Sciences Directorate, Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2014-12-28

    We present a comprehensive simulation study on the solid-liquid phase transition of the ionic liquid 1,3-dimethylimidazolium chloride in terms of the changes in the atomic structure and their effect on the Compton profile. The structures were obtained by using ab initio molecular dynamics simulations. Chosen radial distribution functions of the liquid structure are presented and found generally to be in good agreement with previous ab initio molecular dynamics and neutron scattering studies. The main contributions to the predicted difference Compton profile are found to arise from intermolecular changes in the phase transition. This prediction can be used for interpreting future experiments.

  12. Feasibility of a novel design of high resolution parallax-free Compton enhanced PET scanner dedicated to brain research

    CERN Document Server

    Braem, André; Chesi, Enrico Guido; Correia, J G; Garibaldi, F; Joram, C; Mathot, S; Nappi, E; Ribeiro da Silva, M; Schoenahl, F; Séguinot, Jacques; Weilhammer, P; Zaidi, H

    2004-01-01

    A novel concept for a positron emission tomography (PET) camera module is proposed, which provides full 3D reconstruction with high resolution over the total detector volume, free of parallax errors. The key components are a matrix of long scintillator crystals and hybrid photon detectors (HPDs) with matched segmentation and integrated readout electronics. The HPDs read out the two ends of the scintillator package. Both excellent spatial (x, y, z) and energy resolution are obtained. The concept allows enhancing the detection efficiency by reconstructing a significant fraction of events which underwent Compton scattering in the crystals. The proof of concept will first be demonstrated with yttrium orthoaluminate perovskite (YAP):Ce crystals, but the final design will rely on other scintillators more adequate for PET applications (e.g. LSO:Ce or LaBr /sub 3/:Ce). A promising application of the proposed camera module, which is currently under development, is a high resolution 3D brain PET camera with an axial fi...

  13. Development of a Compton camera for prompt-gamma medical imaging

    Science.gov (United States)

    Aldawood, S.; Thirolf, P. G.; Miani, A.; Böhmer, M.; Dedes, G.; Gernhäuser, R.; Lang, C.; Liprandi, S.; Maier, L.; Marinšek, T.; Mayerhofer, M.; Schaart, D. R.; Lozano, I. Valencia; Parodi, K.

    2017-11-01

    A Compton camera-based detector system for photon detection from nuclear reactions induced by proton (or heavier ion) beams is under development at LMU Munich, targeting the online range verification of the particle beam in hadron therapy via prompt-gamma imaging. The detector is designed to be capable to reconstruct the photon source origin not only from the Compton scattering kinematics of the primary photon, but also to allow for tracking of the secondary Compton-scattered electrons, thus enabling a γ-source reconstruction also from incompletely absorbed photon events. The Compton camera consists of a monolithic LaBr3:Ce scintillation crystal, read out by a multi-anode PMT acting as absorber, preceded by a stacked array of 6 double-sided silicon strip detectors as scatterers. The detector components have been characterized both under offline and online conditions. The LaBr3:Ce crystal exhibits an excellent time and energy resolution. Using intense collimated 137Cs and 60Co sources, the monolithic scintillator was scanned on a fine 2D grid to generate a reference library of light amplitude distributions that allows for reconstructing the photon interaction position using a k-Nearest Neighbour (k-NN) algorithm. Systematic studies were performed to investigate the performance of the reconstruction algorithm, revealing an improvement of the spatial resolution with increasing photon energy to an optimum value of 3.7(1)mm at 1.33 MeV, achieved with the Categorical Average Pattern (CAP) modification of the k-NN algorithm.

  14. Characterization of CT beams using Compton spectrometry; Caracterização de feixes de TC utilizando Espectrometria Compton

    Energy Technology Data Exchange (ETDEWEB)

    Terini, Ricardo A.; Nerssissian, Denise Y.; Campelo, Maria Carolina S.; Yoshimura, Elisabeth M., E-mail: rterini@if.usp.br [Universidade de São Paulo (LDRFM/USP), SP (Brazil). Lab. de Dosimetria das Radiações e Física Médica

    2017-07-01

    Obtaining the energy spectra of computed tomography (CT) X-ray beams is essential, helping to obtain parameters that characterize beam quality and equipment performance. However, CT photon fluxes are too high to have the spectra measured directly with common photon counting detectors. In this work, a Compton spectrometer was designed, with Al-Pb-Al collimators and shields, as well as a cadmium telluride (CdTe) detector to get the spectrum of CT beams, from the measurement of the spectrum of a beam scattered at 90 deg by a polymethyl-methacrylate (PMMA) rod. A MatLab® computer code was developed, using the Waller-Hartree formalism, to reconstruct the spectrum of the incident beam, from the measured scattered beam spectrum. Tests at IF-USP Laboratory of Radiation Dosimetry and Medical Physics with standard CT beams showed that the reconstructed spectrum is alike the directly measured beam. Shielding influence and scatterer thickness were investigated. The system was tested in measurements on a GE 690 CT scanner, showing practical positioning on the exam table, and alignment with CT lasers refined by scan projection radiography. Spectra obtained with the properly shielded system presented values of half-value layer (HVL) compatible with those measured in QC tests and kVp values with accuracy to evaluate the scanner voltage calibration. (author)

  15. Compton profile of polycrystalline sodium chloride and sodium fluoride

    International Nuclear Information System (INIS)

    Vijayakumar, R.; Shivaramu; Rajasekaran, L.; Ramamurthy, N.; Ford, M.J.

    2005-01-01

    We present here the Compton profile (CP) of polycrystalline sodium chloride and sodium fluoride. Our results consists of spherical average Compton profile based on measurements and calculation of spherical average Compton profile, directional Compton profile and their anisotropic effect using self-consistent Hartree-Fock wave functions employed on the linear combination of atomic orbital (HF-LCAO) approximation. The experimental results are compared with the HF-LCAO spherical average Compton profile and with tabulated Hartree-Fock free atom results. For both compounds the experimental results are found to be in good agreement with the HF-LCAO results and in qualitative agreement with Hartree-Fock free atom values

  16. BOW TIES IN THE SKY. I. THE ANGULAR STRUCTURE OF INVERSE COMPTON GAMMA-RAY HALOS IN THE FERMI SKY

    Energy Technology Data Exchange (ETDEWEB)

    Broderick, Avery E.; Shalaby, Mohamad [Department of Physics and Astronomy, University of Waterloo, 200 University Avenue West, Waterloo, ON, N2L 3G1 (Canada); Tiede, Paul [Perimeter Institute for Theoretical Physics, 31 Caroline Street North, Waterloo, ON, N2L 2Y5 (Canada); Pfrommer, Christoph [Heidelberg Institute for Theoretical Studies, Schloss-Wolfsbrunnenweg 35, D-69118 Heidelberg (Germany); Puchwein, Ewald [Institute of Astronomy and Kavli Institute for Cosmology, University of Cambridge, Madingley Road, Cambridge, CB3 0HA (United Kingdom); Chang, Philip [Department of Physics, University of Wisconsin-Milwaukee, 1900 E. Kenwood Boulevard, Milwaukee, WI 53211 (United States); Lamberts, Astrid [Theoretical Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States)

    2016-12-01

    Extended inverse Compton halos are generally anticipated around extragalactic sources of gamma rays with energies above 100 GeV. These result from inverse Compton scattered cosmic microwave background photons by a population of high-energy electron/positron pairs produced by the annihilation of the high-energy gamma rays on the infrared background. Despite the observed attenuation of the high-energy gamma rays, the halo emission has yet to be directly detected. Here, we demonstrate that in most cases these halos are expected to be highly anisotropic, distributing the upscattered gamma rays along axes defined either by the radio jets of the sources or oriented perpendicular to a global magnetic field. We present a pedagogical derivation of the angular structure in the inverse Compton halo and provide an analytic formalism that facilitates the generation of mock images. We discuss exploiting this fact for the purpose of detecting gamma-ray halos in a set of companion papers.

  17. A Germanium Detector with Optimized Compton Veto for High Sensitivity at Low Energy

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, S

    2011-11-30

    We have built a prototype germanium detector with a Compton veto that is optimized for high sensitivity in the low-energy range around {approx}100 keV. It is specifically designed to address the problem to directly detect plutonium gamma emissions in spent nuclear fuel by non-destructive assay. This is not possible with current detectors due to the large low-energy background of Compton-scattered high-energy radiation from the fission products, whose gamma flux is at least 6 to 7 orders of magnitude higher than the Pu signal. Our instrument is designed to assess the feasibility to selectively suppress the background in the low-energy region around {approx}100 keV with the strongest Pu X-ray and gamma emissions lines. It employs a thin Ge detector with a large Compton veto directly behind it to suppress the background from forward-scattered radiation by anti-coincidence vetoing. This report summarizes the design considerations and the performance of the instrument.

  18. Using triple gamma coincidences with a pixelated semiconductor Compton-PET scanner: a simulation study

    Science.gov (United States)

    Kolstein, M.; Chmeissani, M.

    2016-01-01

    The Voxel Imaging PET (VIP) Pathfinder project presents a novel design using pixelated semiconductor detectors for nuclear medicine applications to achieve the intrinsic image quality limits set by physics. The conceptual design can be extended to a Compton gamma camera. The use of a pixelated CdTe detector with voxel sizes of 1 × 1 × 2 mm3 guarantees optimal energy and spatial resolution. However, the limited time resolution of semiconductor detectors makes it impossible to use Time Of Flight (TOF) with VIP PET. TOF is used in order to improve the signal to noise ratio (SNR) by using only the most probable portion of the Line-Of-Response (LOR) instead of its entire length. To overcome the limitation of CdTe time resolution, we present in this article a simulation study using β+-γ emitting isotopes with a Compton-PET scanner. When the β+ annihilates with an electron it produces two gammas which produce a LOR in the PET scanner, while the additional gamma, when scattered in the scatter detector, provides a Compton cone that intersects with the aforementioned LOR. The intersection indicates, within a few mm of uncertainty along the LOR, the origin of the beta-gamma decay. Hence, one can limit the part of the LOR used by the image reconstruction algorithm.

  19. Compton backscattered annihilation line emission: A new diagnostic of accreting compact sources

    Science.gov (United States)

    Lingenfelter, Richard E.; Hua, Xin-Min

    1992-01-01

    It is shown that Compton scattering of 511 keV electron-positron annihilation radiation produces a line like feature at approx. 170 keV from backscattered photons. Assuming a simple model of an accretion disk around a compact source, the spectrum is explored of the spectrum of Compton scattered annihilation line emission for a range of conditions. It is further shown that such Compton baskscattering of annihilation line emission from the inner edge of an accretion disk could account for the previously unidentified 170 keV line emission and high energy continuum observed from a variable, compact source, or sources, of annihilation radiation near the Galactic Center. Identification of the observed 170 keV line as an annihilation line reflection feature provides strong new evidence that the source of the emission is an accreting compact object. Further study of these features in existing spectra and in forthcoming GRO observation of these and other sources can provide unique new diagnostics of the innermost regions of accretion disks around compact objects.

  20. Advanced Laser-Compton Gamma-Ray Sources for Nuclear Materials Detection, Assay and Imaging

    Science.gov (United States)

    Barty, C. P. J.

    2015-10-01

    Highly-collimated, polarized, mono-energetic beams of tunable gamma-rays may be created via the optimized Compton scattering of pulsed lasers off of ultra-bright, relativistic electron beams. Above 2 MeV, the peak brilliance of such sources can exceed that of the world's largest synchrotrons by more than 15 orders of magnitude and can enable for the first time the efficient pursuit of nuclear science and applications with photon beams, i.e. Nuclear Photonics. Potential applications are numerous and include isotope-specific nuclear materials management, element-specific medical radiography and radiology, non-destructive, isotope-specific, material assay and imaging, precision spectroscopy of nuclear resonances and photon-induced fission. This review covers activities at the Lawrence Livermore National Laboratory related to the design and optimization of mono-energetic, laser-Compton gamma-ray systems and introduces isotope-specific nuclear materials detection and assay applications enabled by them.

  1. Development of a Compton camera for online ion beam range verification via prompt γ detection

    Energy Technology Data Exchange (ETDEWEB)

    Aldawood, S. [LMU Munich, Garching (Germany); King Saud University, Riyadh (Saudi Arabia); Liprandi, S.; Marinsek, T.; Bortfeldt, J.; Lang, C.; Lutter, R.; Dedes, G.; Parodi, K.; Thirolf, P.G. [LMU Munich, Garching (Germany); Maier, L.; Gernhaeuser, R. [TU Munich, Garching (Germany); Kolff, H. van der [LMU Munich, Garching (Germany); TU Delft (Netherlands); Castelhano, I. [LMU Munich, Garching (Germany); University of Lisbon, Lisbon (Portugal); Schaart, D.R. [TU Delft (Netherlands)

    2015-07-01

    Precise and preferably online ion beam range verification is a mandatory prerequisite to fully exploit the advantages of hadron therapy in cancer treatment. An imaging system is being developed in Garching aiming to detect promptγ rays induced by nuclear reactions between the ion beam and biological tissue. The Compton camera prototype consists of a stack of six customized double-sided Si-strip detectors (DSSSD, 50 x 50 mm{sup 2}, 0.5 mm thick, 128 strips/side) acting as scatterer, while the absorber is formed by a monolithic LaBr{sub 3}:Ce scintillator crystal (50 x 50 x 30 mm{sup 3}) read out by a position-sensitive multi-anode photomultiplier (Hamamatsu H9500). The on going characterization of the Compton camera properties and its individual components both offline in the laboratory as well as online using proton beam are presented.

  2. Polarized γ source based on Compton backscattering in a laser cavity

    Directory of Open Access Journals (Sweden)

    V. Yakimenko

    2006-09-01

    Full Text Available We propose a novel gamma source suitable for generating a polarized positron beam for the next generation of electron-positron colliders, such as the International Linear Collider (ILC, and the Compact Linear Collider (CLIC. This 30-MeV polarized gamma source is based on Compton scattering inside a picosecond CO_{2} laser cavity generated from electron bunches produced by a 4-GeV linac. We identified and experimentally verified the optimum conditions for obtaining at least one gamma photon per electron. After multiplication at several consecutive interaction points, the circularly polarized gamma rays are stopped on a target, thereby creating copious numbers of polarized positrons. We address the practicality of having an intracavity Compton-polarized positron source as the injector for these new colliders.

  3. A novel comparison of Møller and Compton electron-beam polarimeters

    Directory of Open Access Journals (Sweden)

    J.A. Magee

    2017-03-01

    Full Text Available We have performed a novel comparison between electron-beam polarimeters based on Møller and Compton scattering. A sequence of electron-beam polarization measurements were performed at low beam currents (<5 μA during the Qweak experiment in Hall-C at Jefferson Lab. These low current measurements were bracketed by the regular high current (180 μA operation of the Compton polarimeter. All measurements were found to be consistent within experimental uncertainties of 1% or less, demonstrating that electron polarization does not depend significantly on the beam current. This result lends confidence to the common practice of applying Møller measurements made at low beam currents to physics experiments performed at higher beam currents. The agreement between two polarimetry techniques based on independent physical processes sets an important benchmark for future precision asymmetry measurements that require sub-1% precision in polarimetry.

  4. Compton effect in terms of spintronic

    Directory of Open Access Journals (Sweden)

    Ziya Saglam

    Full Text Available Compton effect with spin effect is studied. Although the incoming wave has been taken into account in the current loop model the final result is the same as before. Namely, the total angular momentum in z-direction before the collision will be equal to the total angular momentum after the collision. Let us take the z-component of the spin of the incident light as, (1, 0, −1 and the spin of the electron as, (½, −½. Applying the conservation of the z-component of the total angular momentum gives access to spin-flips. We find that the probability of spin-flip is 40%. We believe that this analysis will be helpful for deepening in the spintronic event better. Keywords: Compton effect, Spin-flip, Total angular momentum

  5. Scattering and absorption differential cross sections for double ...

    Indian Academy of Sciences (India)

    The scattering and absorption differential cross sections for nonlinear QED process such as double photon Compton scattering have been measured as a function of independent final photon energy. The incident gamma photons are of 0.662 MeV in energy as produced by an 8 Ci137Cs radioactive source and thin ...

  6. Electronic structure of hafnium: A Compton profile study

    Indian Academy of Sciences (India)

    In this paper, we report the first-ever isotropic Compton profile of hafnium measured at an intermediate resolution, with 661.65 keV γ-radiation. To compare ... 0.38 a.u. The raw data were accumulated for about 350 h resulting in an integrated. Compton intensity of 2.6 × 107 photons in the Compton profile region. To extract ...

  7. MEASUREMENT OF LOW ENERGY DETECTION EFFICIENCY OF A PLASTIC SCINTILLATOR: IMPLICATIONS ON THE LOWER ENERGY LIMIT AND SENSITIVITY OF A HARD X-RAY FOCAL PLANE COMPTON POLARIMETER

    International Nuclear Information System (INIS)

    Chattopadhyay, T.; Vadawale, S. V.; Shanmugam, M.; Goyal, S. K.

    2014-01-01

    The polarization measurements in X-rays offer a unique opportunity for the study of physical processes under the extreme conditions prevalent at compact X-ray sources, including gravitation, magnetic field, and temperature. Unfortunately, there has been no real progress in observational X-ray polarimetry thus far. Although photoelectron tracking-based X-ray polarimeters provide realistic prospects of polarimetric observations, they are effective in the soft X-rays only. With the advent of hard X-ray optics, it has become possible to design sensitive X-ray polarimeters in hard X-rays based on Compton scattering. An important point that should be carefully considered for the Compton polarimeters is the lower energy threshold of the active scatterer, which typically consists of a plastic scintillator due to its lowest effective atomic number. Therefore, an accurate understanding of the plastic scintillators energy threshold is essential to make a realistic estimate of the energy range and sensitivity of any Compton polarimeter. In this context, we set up an experiment to investigate the plastic scintillators behavior for very low energy deposition events. The experiment involves the detection of Compton scattered photons from a long, thin, plastic scintillator (a similar configuration as the eventual Compton polarimeter) by a high resolution CdTe detector at different scattering angles. We find that it is possible to detect energy deposition well below 1 keV, though with decreasing efficiency. We present detailed semianalytical modeling of our experimental setup and discuss the results in the context of the energy range and sensitivity of the Compton polarimeter involving plastic scintillators

  8. Deep Inelastic Scattering at the Amplitude Level

    International Nuclear Information System (INIS)

    Brodsky, Stanley J.

    2005-01-01

    The deep inelastic lepton scattering and deeply virtual Compton scattering cross sections can be interpreted in terms of the fundamental wavefunctions defined by the light-front Fock expansion, thus allowing tests of QCD at the amplitude level. The AdS/CFT correspondence between gauge theory and string theory provides remarkable new insights into QCD, including a model for hadronic wavefunctions which display conformal scaling at short distances and color confinement at large distances

  9. Gaining improved chemical composition by exploitation of Compton-to-Rayleigh intensity ratio in XRF analysis.

    Science.gov (United States)

    Hodoroaba, Vasile-Dan; Rackwitz, Vanessa

    2014-07-15

    The high specificity of the coherent (Rayleigh), as well as incoherent (Compton) X-ray scattering to the mean atomic number of a specimen to be analyzed by X-ray fluorescence (XRF), is exploited to gain more information on the chemical composition. Concretely, the evaluation of the Compton-to-Rayleigh intensity ratio from XRF spectra and its relation to the average atomic number of reference materials via a calibration curve can reveal valuable information on the elemental composition complementary to that obtained from the reference-free XRF analysis. Particularly for matrices of lower mean atomic numbers, the sensitivity of the approach is so high that it can be easily distinguished between specimens of mean atomic numbers differing from each other by 0.1. Hence, the content of light elements which are "invisible" for XRF, particularly hydrogen, or of heavier impurities/additives in light materials can be calculated "by difference" from the scattering calibration curve. The excellent agreement between such an experimental, empirical calibration curve and a synthetically generated one, on the basis of a reliable physical model for the X-ray scattering, is also demonstrated. Thus, the feasibility of the approach for given experimental conditions and particular analytical questions can be tested prior to experiments with reference materials. For the present work a microfocus X-ray source attached on an SEM/EDX (scanning electron microscopy/energy dispersive X-ray spectroscopy) system was used so that the Compton-to-Rayleigh intensity ratio could be acquired with EDX spectral data for improved analysis of the elemental composition.

  10. Applications of Gas Imaging Micro-Well Detectors to an Advanced Compton Telescope

    Science.gov (United States)

    Bloser, P. F.; Hunter, S. D.; Ryan, J. M.; McConnell, M. L.; Miller, R. S.; Jackson, T. N.; Bai, B.; Jung, S.

    2003-01-01

    We present a concept for an Advanced Compton Telescope (ACT) based on the use of pixelized gas micro-well detectors to form a three-dimensional electron track imager. A micro-well detector consists of an array of individual micro-patterned proportional counters opposite a planar drift electrode. When combined with thin film transistor array readouts, large gas volumes may be imaged with very good spatial and energy resolution at reasonable cost. The third dimension is determined by timing the drift of the ionization electrons. The primary advantage of this approach is the excellent tracking of the Compton recoil electron that is possible in a gas volume. Such good electron tracking allows us to reduce the point spread function of a single incident photon dramatically, greatly improving the imaging capability and sensitivity. The polarization sensitivity, which relies on events with large Compton scattering angles, is particularly enhanced. We describe a possible ACT implementation of this technique, in which the gas tracking volume is surrounded by a CsI calorimeter, and present our plans to build and test a small prototype over the next three years.

  11. Determination of Compton profiles in the metal-hydrogen systems VHx, VDx and PdHx

    International Nuclear Information System (INIS)

    Laesser, R.

    1978-02-01

    Compton profiles for polycrystalline PdH(0.72), VD(0.77), VH(0.71), Pd and V have been determined by Compton scattering of 159 keV photons from a Te-123sup(m) source. The difference in profiles before and after hydrogen loading is compared to different models for the electronic structure of the hydrides. It is shown that the Compton profile is a sensitive test of the accuracy of various model wave functions for the hydrides. In both palladium- and vanadium hydride (deuteride) the anionic model (where it is assumed that the hydrogen forms a negative ion H - in the hydride) does not describe the experimental results. The best agreement with the experimental data for PdH(0.72), VD(0.77) and VH(0.71) is obtained for a model which is based on band structure calculations for these hydrides and which takes into account that hydrogen-palladium or hydrogen-vanadium bonding states are created below the Fermi level by the introduction of hydrogen in the host lattice. (orig.) [de

  12. Compton imaging with a highly-segmented, position-sensitive HPGe detector

    Energy Technology Data Exchange (ETDEWEB)

    Steinbach, T.; Hirsch, R.; Reiter, P.; Birkenbach, B.; Bruyneel, B.; Eberth, J.; Hess, H.; Lewandowski, L. [Universitaet zu Koeln, Institut fuer Kernphysik, Koeln (Germany); Gernhaeuser, R.; Maier, L.; Schlarb, M.; Weiler, B.; Winkel, M. [Technische Universitaet Muenchen, Physik Department, Garching (Germany)

    2017-02-15

    A Compton camera based on a highly-segmented high-purity germanium (HPGe) detector and a double-sided silicon-strip detector (DSSD) was developed, tested, and put into operation; the origin of γ radiation was determined successfully. The Compton camera is operated in two different modes. Coincidences from Compton-scattered γ-ray events between DSSD and HPGe detector allow for best angular resolution; while the high-efficiency mode takes advantage of the position sensitivity of the highly-segmented HPGe detector. In this mode the setup is sensitive to the whole 4π solid angle. The interaction-point positions in the 36-fold segmented large-volume HPGe detector are determined by pulse-shape analysis (PSA) of all HPGe detector signals. Imaging algorithms were developed for each mode and successfully implemented. The angular resolution sensitively depends on parameters such as geometry, selected multiplicity and interaction-point distances. Best results were obtained taking into account the crosstalk properties, the time alignment of the signals and the distance metric for the PSA for both operation modes. An angular resolution between 13.8 {sup circle} and 19.1 {sup circle}, depending on the minimal interaction-point distance for the high-efficiency mode at an energy of 1275 keV, was achieved. In the coincidence mode, an increased angular resolution of 4.6 {sup circle} was determined for the same γ-ray energy. (orig.)

  13. Silicon photomultipliers as readout elements for a Compton effect polarimeter: the COMPASS project

    CERN Document Server

    Del Monte, E; Brandonisio, A; Muleri, F; Soffitta, P; Costa, E; di Persio, G; Cosimo, S Di; Massaro, E; Morbidini, A; Morelli, E; Pacciani, L; Fabiani, S; Michilli, D; Giarrusso, S; Catalano, O; Impiombato, D; Mineo, T; Sottile, G; Billotta, S

    2016-01-01

    COMpton Polarimeter with Avalanche Silicon readout (COMPASS) is a research and development project that aims to measure the polarization of X-ray photons through Compton Scattering. The measurement is obtained by using a set of small rods of fast scintillation materials with both low-Z (as active scatterer) and high-Z (as absorber), all read-out with Silicon Photomultipliers. By this method we can operate scattering and absorbing elements in coincidence, in order to reduce the background. In the laboratory we are characterising the SiPMs using different types of scintillators and we are optimising the performances in terms of energy resolution, energy threshold and photon tagging efficiency. We aim to study the design of two types of satellite-borne instruments: a focal plane polarimeter to be coupled with multilayer optics for hard X-rays and a large area and wide field of view polarimeter for transients and Gamma Ray Bursts. In this paper we describe the status of the COMPASS project, we report about the la...

  14. Positioning of steel rods inclusions in reinforced concrete simulant by Compton backscattering

    Energy Technology Data Exchange (ETDEWEB)

    Boldo, Emerson M.; Prestes, Ana A.P.; Appoloni, Carlos R. [Universidade Estadual de Londrina (UEL), PR (Brazil). Dept. de Fisica. Lab. de Fisica Nuclear Aplicada

    2011-07-01

    Reinforced concrete is susceptible to a range of environmental degradation factors that can limit its service life. There has always been a need for test methods to measure, in situ, the properties of concrete for quality assurance and to evaluate the condition of existing structures. Compton scattering of gamma radiation is a nondestructive technique used for the detection of defects and inclusions in materials and it can be employed on reinforced concrete. The methodology allows for one-side inspection of large structures and can be implemented with a relatively inexpensive, portable apparatus. In this work, we used the Compton backscattering technique to measure both the size and depth of steel rod inclusions in plaster block samples. The samples were irradiated with gamma rays from a {phi}2 mm collimated {sup 241}Am (100 mCi) source, and the inelastically scattered photons were collected at an angle of 135 deg by a high-resolution CdTe semiconductor detector. Scanning was achieved by lateral movement of the sample blocks across the field of view of the source and detector in steps of 1 mm. The tests on plaster blocks with steel rod inclusions suggest that, for a low-energy and low-activity gamma source, beam attenuation has greater effects on the scattered intensity than does increased material density. Density contrast analysis allows determination of the size and depth of steel rods. Furthermore, the experimental results agree with theoretical data obtained through Monte Carlo simulation. (author)

  15. Theoretical Compton profile anisotropies in molecules and solids. VI. Compton profile anisotropies and chemical binding

    Energy Technology Data Exchange (ETDEWEB)

    Matcha, R.L.; Pettitt, B.M.

    1979-03-15

    An interesting empirical relationship between zero point Compton profile anisotropies ..delta..J (0) and nuclear charges is noted. It is shown that, for alkali halide molecules AB, to a good approximation ..delta..J (0) =N ln(Z/sub b//Z/sub a/).

  16. Development of a Compton camera for medical applications based on silicon strip and scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Krimmer, J., E-mail: j.krimmer@ipnl.in2p3.fr [Institut de Physique Nucléaire de Lyon, Université de Lyon, Université Lyon 1, CNRS/IN2P3 UMR 5822, 69622 Villeurbanne cedex (France); Ley, J.-L. [Institut de Physique Nucléaire de Lyon, Université de Lyon, Université Lyon 1, CNRS/IN2P3 UMR 5822, 69622 Villeurbanne cedex (France); Abellan, C.; Cachemiche, J.-P. [Aix-Marseille Université, CNRS/IN2P3, CPPM UMR 7346, 13288 Marseille (France); Caponetto, L.; Chen, X.; Dahoumane, M.; Dauvergne, D. [Institut de Physique Nucléaire de Lyon, Université de Lyon, Université Lyon 1, CNRS/IN2P3 UMR 5822, 69622 Villeurbanne cedex (France); Freud, N. [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA - Lyon, Université Lyon 1, Centre Léon Bérard (France); Joly, B.; Lambert, D.; Lestand, L. [Clermont Université, Université Blaise Pascal, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, F-63000 Clermont-Ferrand (France); Létang, J.M. [Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA - Lyon, Université Lyon 1, Centre Léon Bérard (France); Magne, M. [Clermont Université, Université Blaise Pascal, CNRS/IN2P3, Laboratoire de Physique Corpusculaire, BP 10448, F-63000 Clermont-Ferrand (France); and others

    2015-07-01

    A Compton camera is being developed for the purpose of ion-range monitoring during hadrontherapy via the detection of prompt-gamma rays. The system consists of a scintillating fiber beam tagging hodoscope, a stack of double sided silicon strip detectors (90×90×2 mm{sup 3}, 2×64 strips) as scatter detectors, as well as bismuth germanate (BGO) scintillation detectors (38×35×30 mm{sup 3}, 100 blocks) as absorbers. The individual components will be described, together with the status of their characterization.

  17. Cork quality estimation by using Compton tomography

    CERN Document Server

    Brunetti, A; Golosio, B; Luciano, P; Ruggero, A

    2002-01-01

    The quality control of cork stoppers is mandatory in order to guarantee the perfect conservation of the wine. Several techniques have been developed but until now the quality control was essentially related to the status of the external surface. Thus possible cracks or holes inside the stopper will be hidden. In this paper a new technique based on X-ray Compton tomography is described. It is a non-destructive technique that allows one to reconstruct and visualize the cross-section of the cork stopper analyzed, and so to put in evidence the presence of internal imperfections. Some results are reported and compared with visual classification.

  18. Beam dynamics in Compton ring gamma sources

    Directory of Open Access Journals (Sweden)

    Eugene Bulyak

    2006-09-01

    Full Text Available Electron storage rings of GeV energy with laser pulse stacking cavities are promising intense sources of polarized hard photons which, via pair production, can be used to generate polarized positron beams. In this paper, the dynamics of electron bunches circulating in a storage ring and interacting with high-power laser pulses is studied both analytically and by simulation. Both the common features and the differences in the behavior of bunches interacting with an extremely high power laser pulse and with a moderate pulse are discussed. Also considerations on particular lattice designs for Compton gamma rings are presented.

  19. Cork quality estimation by using Compton tomography

    Science.gov (United States)

    Brunetti, Antonio; Cesareo, Roberto; Golosio, Bruno; Luciano, Pietro; Ruggero, Alessandro

    2002-11-01

    The quality control of cork stoppers is mandatory in order to guarantee the perfect conservation of the wine. Several techniques have been developed but until now the quality control was essentially related to the status of the external surface. Thus possible cracks or holes inside the stopper will be hidden. In this paper a new technique based on X-ray Compton tomography is described. It is a non-destructive technique that allows one to reconstruct and visualize the cross-section of the cork stopper analyzed, and so to put in evidence the presence of internal imperfections. Some results are reported and compared with visual classification.

  20. Image reconstruction from limited angle Compton camera data

    International Nuclear Information System (INIS)

    Tomitani, T.; Hirasawa, M.

    2002-01-01

    The Compton camera is used for imaging the distributions of γ ray direction in a γ ray telescope for astrophysics and for imaging radioisotope distributions in nuclear medicine without the need for collimators. The integration of γ rays on a cone is measured with the camera, so that some sort of inversion method is needed. Parra found an analytical inversion algorithm based on spherical harmonics expansion of projection data. His algorithm is applicable to the full set of projection data. In this paper, six possible reconstruction algorithms that allow image reconstruction from projections with a finite range of scattering angles are investigated. Four algorithms have instability problems and two others are practical. However, the variance of the reconstructed image diverges in these two cases, so that window functions are introduced with which the variance becomes finite at a cost of spatial resolution. These two algorithms are compared in terms of variance. The algorithm based on the inversion of the summed back-projection is superior to the algorithm based on the inversion of the summed projection. (author)

  1. Image reconstruction from limited angle Compton camera data

    Science.gov (United States)

    Tomitani, T.; Hirasawa, M.

    2002-06-01

    The Compton camera is used for imaging the distributions of γ ray direction in a γ ray telescope for astrophysics and for imaging radioisotope distributions in nuclear medicine without the need for collimators. The integration of γ rays on a cone is measured with the camera, so that some sort of inversion method is needed. Parra found an analytical inversion algorithm based on spherical harmonics expansion of projection data. His algorithm is applicable to the full set of projection data. In this paper, six possible reconstruction algorithms that allow image reconstruction from projections with a finite range of scattering angles are investigated. Four algorithms have instability problems and two others are practical. However, the variance of the reconstructed image diverges in these two cases, so that window functions are introduced with which the variance becomes finite at a cost of spatial resolution. These two algorithms are compared in terms of variance. The algorithm based on the inversion of the summed back-projection is superior to the algorithm based on the inversion of the summed projection.

  2. Advanced PET using both Compton and photoelectric events

    International Nuclear Information System (INIS)

    Yoon, Changyeon; Lee, Wonho

    2012-01-01

    This study presents image reconstruction and evaluation of advanced positron emission tomography (PET) by using a simple backprojection and an maximum likelihood expectation maximization (MLEM) method. Advanced PET can use not only the photoelectric effect but also the Compton scattering effect for image reconstruction; hence, the detection efficiency should be inherently higher than that of conventional PET. By using a voxelized cadmium zinc telluride (CZT) detector, the detected position and deposited energy of the gamma ray were found precisely. With the position and energy information, the interaction sequence, which is one of the main factors to consider in the reconstruction of the source image, was identified correctly. The reconstruction algorithms were simple backprojection and MLEM methods, and three methods were used to evaluate the advanced PET compared with conventional PET, which uses the photoelectric effect only. The full widths at half maximum (FWHM) and the maximum counts of images reconstructed by using simple backprojection were calculated for comparison. Using an MLEM method, the FWHM and the relative standard deviation of the counts in the range of half of the FWHM around the maximum pixel were calculated at each iteration to evaluate the modalities quantitatively. For a 3D source phantom, the simple backprojection and the MLEM methods were applied to each modality, and the reconstructed images were compared with each other by using the relative standard deviation for each component of the reconstructed image and by using visual inspection.

  3. Compton-backscattered annihilation radiation from the Galactic Center region

    Science.gov (United States)

    Smith, D. M.; Lin, R. P.; Feffer, P.; Slassi, S.; Hurley, K.; Matteson, J.; Bowman, H. B.; Pelling, R. M.; Briggs, M.; Gruber, D.

    1993-01-01

    On 1989 May 22, the High Energy X-ray and Gamma-ray Observatory for Nuclear Emissions, a balloon-borne high-resolution germanium spectrometer with an 18-deg FOV, observed the Galactic Center (GC) from 25 to 2500 keV. The GC photon spectrum is obtained from the count spectrum by a model-independent method which accounts for the effects of passive material in the instrument and scattering in the atmosphere. Besides a positron annihilation line with a flux of (10.0 +/- 2.4) x 10 exp -4 photons/sq cm s and a full width at half-maximum (FWHM) of (2.9 + 1.0, -1.1) keV, the spectrum shows a peak centered at (163.7 +/- 3.4) keV with a flux of (1.55 +/- 0.47) x 10 exp -3 photons/sq cm s and a FWHM of (24.4 +/- 9.2) keV. The energy range 450-507 keV shows no positronium continuum associated with the annihilation line, with a 2-sigma upper limit of 0.90 on the positronium fraction. The 164 keV feature is interpreted as Compton backscatter of broadened and redshifted annihilation radiation, possibly from the source 1E 1740.7-2942.

  4. Simulation of Laser-Compton Cooling of Electron Beams

    OpenAIRE

    Ohgaki, T.

    2000-01-01

    We study a method of laser-Compton cooling of electron beams. Using a Monte Carlo code, we evaluate the effects of the laser-electron interaction for transverse cooling. The optics with and without chromatic correction for the cooling are examined. The laser-Compton cooling for JLC/NLC at E_0=2 GeV is considered.

  5. Recent results from the Compton Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Michelson, P.F.; Hansen, W.W. [Stanford Univ., CA (United States)

    1994-12-01

    The Compton Observatory is an orbiting astronomical observatory for gamma-ray astronomy that covers the energy range from about 30 keV to 30 GeV. The Energetic Gamma Ray Experiment Telescope (EGRET), one of four instruments on-board, is capable of detecting and imaging gamma radiation from cosmic sources in the energy range from approximately 20 MeV to 30 GeV. After about one month of tests and calibration following the April 1991 launch, a 15-month all sky survey was begun. This survey is now complete and the Compton Observatory is well into Phase II of its observing program which includes guest investigator observations. Among the highlights from the all-sky survey discussed in this presentation are the following: detection of five pulsars with emission above 100 MeV; detection of more than 24 active galaxies, the most distant at redshift greater than two; detection of many high latitude, unidentified gamma-ray sources, some showing significant time variability; detection of at least two high energy gamma-ray bursts, with emission in one case extending to at least 1 GeV. EGRET has also detected gamma-ray emission from solar flares up to energies of at least 2 GeV and has observed gamma-rays from the Large Magellanic Cloud.

  6. A dual purpose Compton suppression spectrometer

    CERN Document Server

    Parus, J; Raab, W; Donohue, D

    2003-01-01

    A gamma-ray spectrometer with a passive and an active shield is described. It consists of a HPGe coaxial detector of 42% efficiency and 4 NaI(Tl) detectors. The energy output pulses of the Ge detector are delivered into the 3 spectrometry chains giving the normal, anti- and coincidence spectra. From the spectra of a number of sup 1 sup 3 sup 7 Cs and sup 6 sup 0 Co sources a Compton suppression factor, SF and a Compton reduction factor, RF, as the parameters characterizing the system performance, were calculated as a function of energy and source activity and compared with those given in literature. The natural background is reduced about 8 times in the anticoincidence mode of operation, compared to the normal spectrum which results in decreasing the detection limits for non-coincident gamma-rays up to a factor of 3. In the presence of other gamma-ray activities, in the range from 5 to 11 kBq, non- and coincident, the detection limits can be decreased for some nuclides by a factor of 3 to 5.7.

  7. Gamma-ray detection and Compton camera image reconstruction with application to hadron therapy

    International Nuclear Information System (INIS)

    Frandes, M.

    2010-09-01

    A novel technique for radiotherapy - hadron therapy - irradiates tumors using a beam of protons or carbon ions. Hadron therapy is an effective technique for cancer treatment, since it enables accurate dose deposition due to the existence of a Bragg peak at the end of particles range. Precise knowledge of the fall-off position of the dose with millimeters accuracy is critical since hadron therapy proved its efficiency in case of tumors which are deep-seated, close to vital organs, or radio-resistant. A major challenge for hadron therapy is the quality assurance of dose delivery during irradiation. Current systems applying positron emission tomography (PET) technologies exploit gamma rays from the annihilation of positrons emitted during the beta decay of radioactive isotopes. However, the generated PET images allow only post-therapy information about the deposed dose. In addition, they are not in direct coincidence with the Bragg peak. A solution is to image the complete spectrum of the emitted gamma rays, including nuclear gamma rays emitted by inelastic interactions of hadrons to generated nuclei. This emission is isotropic, and has a spectrum ranging from 100 keV up to 20 MeV. However, the measurement of these energetic gamma rays from nuclear reactions exceeds the capability of all existing medical imaging systems. An advanced Compton scattering detection method with electron tracking capability is proposed, and modeled to reconstruct the high-energy gamma-ray events. This Compton detection technique was initially developed to observe gamma rays for astrophysical purposes. A device illustrating the method was designed and adapted to Hadron Therapy Imaging (HTI). It consists of two main sub-systems: a tracker where Compton recoiled electrons are measured, and a calorimeter where the scattered gamma rays are absorbed via the photoelectric effect. Considering a hadron therapy scenario, the analysis of generated data was performed, passing trough the complete

  8. Inverse Compton gamma-rays from galactic dark matter annihilation. Anisotropy signatures

    International Nuclear Information System (INIS)

    Zhang, Le; Sigl, Guenter; Miniati, Francesco

    2010-08-01

    High energy electrons and positrons from annihilating dark matter can imprint unique angular anisotropies on the diffuse gamma-ray flux by inverse Compton scattering off the interstellar radiation field. We develop a numerical tool to compute gamma-ray emission from such electrons and positrons diffusing in the smooth host halo and in substructure halos with masses down to 10 -6 M s un. We show that, unlike the total gamma-ray angular power spectrum observed by Fermi-LAT, the angular power spectrum from inverse Compton scattering is exponentially suppressed below an angular scale determined by the diffusion length of electrons and positrons. For TeV scale dark matter with a canonical thermal freeze-out cross section 3 x 10 -26 cm 3 /s, this feature may be detectable by Fermi-LAT in the energy range 100-300 GeV after more sophisticated foreground subtraction. We also find that the total flux and the shape of the angular power spectrum depends sensitively on the spatial distribution of subhalos in the Milky Way. Finally, the contribution from the smooth host halo component to the gamma-ray mean intensity is negligibly small compared to subhalos. (orig.)

  9. Inverse Compton gamma-rays from galactic dark matter annihilation. Anisotropy signatures

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Le; Sigl, Guenter [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Miniati, Francesco [ETH Zuerich (Switzerland). Physics Dept.

    2010-08-15

    High energy electrons and positrons from annihilating dark matter can imprint unique angular anisotropies on the diffuse gamma-ray flux by inverse Compton scattering off the interstellar radiation field. We develop a numerical tool to compute gamma-ray emission from such electrons and positrons diffusing in the smooth host halo and in substructure halos with masses down to 10{sup -6}M{sub s}un. We show that, unlike the total gamma-ray angular power spectrum observed by Fermi-LAT, the angular power spectrum from inverse Compton scattering is exponentially suppressed below an angular scale determined by the diffusion length of electrons and positrons. For TeV scale dark matter with a canonical thermal freeze-out cross section 3 x 10{sup -26} cm{sup 3}/s, this feature may be detectable by Fermi-LAT in the energy range 100-300 GeV after more sophisticated foreground subtraction. We also find that the total flux and the shape of the angular power spectrum depends sensitively on the spatial distribution of subhalos in the Milky Way. Finally, the contribution from the smooth host halo component to the gamma-ray mean intensity is negligibly small compared to subhalos. (orig.)

  10. First coincidences in pre-clinical Compton camera prototype for medical imaging

    Science.gov (United States)

    Studen, A.; Burdette, D.; Chesi, E.; Cindro, V.; Clinthorne, N. H.; Dulinski, W.; Fuster, J.; Han, L.; Kagan, H.; Lacasta, C.; Llosá, G.; Marques, A. C.; Malakhov, N.; Meier, D.; Mikuž, M.; Park, S. J.; Roe, S.; Rogers, W. L.; Steinberg, J.; Weilhammer, P.; Wilderman, S. J.; Zhang, L.; Žontar, D.

    2004-09-01

    Compton collimated imaging may improve the detection of gamma rays emitted by radioisotopes used in single photon emission computed tomography (SPECT). We present a crude prototype consisting of a single 500μm thick, 256 pad silicon detector with pad size of 1.4×1.4mm2, combined with a 15×15×1cm3 NaI scintillator crystal coupled to a set of 20 photo multipliers. Emphasis is placed on the performance of the silicon detector and the associated read-out electronics, which has so far proved to be the most challenging part of the set-up. Results were obtained using the VATAGP3, 128 channel low-noise self-triggering ASIC as the silicon detector's front-end. The noise distribution (σ) of the spectroscopic outputs gave an equivalent noise charge (ENC) with a mean value of =137e with a spread of 10e, corresponding to an energy resolution of 1.15keV FWHM for the scattered electron energy. Threshold settings above 8.2keV were required for stable operation of the trigger. Coincident Compton scatter events in both modules were observed for photons emitted by 57Co source with principal gamma ray energies of 122 and 136keV.

  11. Light Higgs production at the Compton Collider

    International Nuclear Information System (INIS)

    Jikia, G.; Soeldner-Rembold, S.

    2000-01-01

    We have studied the production of a light Higgs boson with a mass of 120 GeV in photon-photon collisions at a Compton collider. The event generator for the backgrounds to a Higgs signal due to b-barb and c-barc heavy quark pair production in polarized γγ collisions is based on a complete next-to-leading order (NLO) perturbative QCD calculation. For J z = 0 the large double-logarithmic corrections up to four loops are also included. It is shown that the two-photon width of the Higgs boson can be measured with high statistical accuracy of about 2% for integrated γγ luminosity in the hard part of the spectrum of 40 fb -1 . As a result the total Higgs boson width can be calculated in a model independent way to an accuracy of about 14%

  12. BLAZAR FLARES FROM COMPTON DRAGGED SHELLS

    Energy Technology Data Exchange (ETDEWEB)

    Golan, Omri; Levinson, Amir, E-mail: Levinson@wise.tau.ac.il [School of Physics and Astronomy, Tel Aviv University, Tel Aviv 69978 (Israel)

    2015-08-10

    We compute the dynamics and emission of dissipative shells that are subject to a strong Compton drag, under simplifying assumptions about the dissipation mechanism. We show that under conditions prevailing in blazars, substantial deceleration is anticipated on sub-parsec and parsec scales in cases of rapid dissipation. Such episodes may be the origin of some of the flaring activity occasionally observed in gamma-ray blazars. The shape of the light curves thereby produced reflects the geometry of the emitting surface if the deceleration is very rapid, or the dynamics of the shell if the deceleration is delayed, or initially more gradual, owing, e.g., to continuous injection of energy and momentum.

  13. Guiding the Design of Radiation Imagers with Experimentally Benchmarked Geant4 Simulations for Electron-Tracking Compton Imaging

    Science.gov (United States)

    Coffer, Amy Beth

    Radiation imagers are import tools in the modern world for a wide range of applications. They span the use-cases of fundamental sciences, astrophysics, medical imaging, all the way to national security, nuclear safeguards, and non-proliferation verification. The type of radiation imagers studied in this thesis were gamma-ray imagers that detect emissions from radioactive materials. Gamma-ray imagers goal is to localize and map the distribution of radiation within their specific field-of-view despite the fact of complicating background radiation that can be terrestrial, astronomical, and temporal. Compton imaging systems are one type of gamma-ray imager that can map the radiation around the system without the use of collimation. Lack of collimation enables the imaging system to be able to detect radiation from all-directions, while at the same time, enables increased detection efficiency by not absorbing incident radiation in non-sensing materials. Each Compton-scatter events within an imaging system generated a possible cone-surface in space that the radiation could have originated from. Compton imaging is limited in its reconstructed image signal-to-background due to these source Compton-cones overlapping with background radiation Compton-cones. These overlapping cones limit Compton imaging's detection-sensitivity in image space. Electron-tracking Compton imaging (ETCI) can improve the detection-sensitivity by measuring the Compton-scattered electron's initial trajectory. With an estimate of the scattered electron's trajectory, one can reduce the Compton-back-projected cone to a cone-arc, thus enabling faster radiation source detection and localization. However, the ability to measure the Compton-scattered electron-trajectories adds another layer of complexity to an already complex methodology. For a real-world imaging applications, improvements are needed in electron-track detection efficiency and in electron-track reconstruction. One way of measuring Compton-scattered

  14. Klein-Nishina electronic cross-section, Compton cross sections, and buildup factor of wax for radiation shielding and protection.

    Science.gov (United States)

    Alenezi, Manar; Stinson, Kayla R; Maqbool, Muhammad; Bolus, Norman

    2018-01-05

    Klein-Nishina scattering cross-sections, Compton scattering, mass attenuation and energy transfer cross-sections, linear attenuation coefficient and buildup factor of paraffin wax are calculated using 0.662 MeV, 0.835 MeV, 1.17 MeV and 1.33 MeV γ-rays. The mentioned γ-rays were obtained from Cs137, Mn54 and Co60 radioisotopes. Gamma rays obtained from these radioisotopes were passed through circular shaped wax slices and allowed to fall on a NaI detector. The thickness of wax slices were 0.33 cm to 2.9 cm with 6 cm diameter. Lead collimator of 1 cm diameter hole in the middle was used to obtain a collimated beam for narrow beam geometry. Broad beam geometry was used by removing collimator, to investigate buildup factor. Results show that Klein-Nishina electronic cross-section, Compton mass attenuation coefficient and Compton energy transfer coefficient all decrease with increasing photon energy. Slope of the thickness vs counts graph for narrow beam geometry gives linear attenuation coefficient μ = 0.0532 cm-1 for 1.17 MeV beam and μ = 0.0419 cm-1 for 1.33 MeV γ-rays. Variations in buildup factors are observed with increasing thickness of wax for 1.17 MeV and 1.33 MeV beams. © 2018 IOP Publishing Ltd.

  15. Compton suppression naa in the analysis of food and beverages

    International Nuclear Information System (INIS)

    Ahmed, Y.A.; Ewa, I.O.B.; Umar, I.M.; Funtua, I.I.; Lanberger, S.; O'kelly, D.J.; Braisted, J.D.

    2009-01-01

    Applicability and performance of Compton suppression method in the analysis of food and beverages was re-established in this study. Using ''1''3''7Cs and ''6''0Co point sources Compton Suppression Factors (SF), Compton Reduction Factors (RF), Peak-to-Compton ratio (P/C), Compton Plateau (C p l), and Compton Edge (C e ) were determined for each of the two sources. The natural background reduction factors in the anticoincidence mode compared to the normal mode were evaluated. The reported R.F. values of the various Compton spectrometers for ''6''0Co source at energy 50-210 keV (backscattering region), 600 keV (Compton edge corresponding to 1173.2 keV gamma-ray) and 1110 keV (Compton edge corresponding to 1332.5 keV gamma-ray) were compared with that of the present work. Similarly the S.F. values of the spectrometers for ''1''3''7Cs source were compared at the backscattered energy region (S.F. b = 191-210 keV), Compton Plateau (S.F. p l = 350-370 keV), and Compton Edge (S.F. e = 471-470 keV) and all were found to follow a similar trend. We also compared peak reduction ratios for the two cobalt energies (1173.2 and 1332.5) with the ones reported in literature and two results agree well. Applicability of the method to food and beverages was put to test for twenty one major, minor, and trace elements (Ba, Sr, I, Br, Cu, V, Mg, Na, Cl, Mn, Ca, Sn,K, Cd, Zn, As, Sb, Ni, Cs, Fe, and Co) commonly found in food, milk, tea and tobacco. The elements were assayed using five National Institute for Standards and Technology (NIST) certified reference materials (Non-fat powdered milk, Apple leaves, Tomato leaves, and Citrus leaves). The results obtained shows good agreement with NIST certified values, indicating that the method is suitable for simultaneous determination of micro-nutrients, macro-nutrients and heavy elements in food and beverages without undue interference problems

  16. Suzaku  Observations of Heavily Obscured (Compton-thick) Active Galactic Nuclei Selected by the Swift/BAT Hard X-Ray Survey

    Science.gov (United States)

    Tanimoto, Atsushi; Ueda, Yoshihiro; Kawamuro, Taiki; Ricci, Claudio; Awaki, Hisamitsu; Terashima, Yuichi

    2018-02-01

    We present a uniform broadband X-ray (0.5–100.0 keV) spectral analysis of 12 Swift/Burst Alert Telescope selected Compton-thick ({log}{N}{{H}}/{{cm}}-2≥slant 24) active galactic nuclei (CTAGNs) observed with Suzaku. The Suzaku data of three objects are published here for the first time. We fit the Suzaku and Swift spectra with models utilizing an analytic reflection code and those utilizing the Monte-Carlo-based model from an AGN torus by Ikeda et al. The main results are as follows: (1) The estimated intrinsic luminosity of a CTAGN strongly depends on the model; applying Compton scattering to the transmitted component in an analytic model may largely overestimate the intrinsic luminosity at large column densities. (2) Unabsorbed reflection components are commonly observed, suggesting that the tori are clumpy. (3) Most of CTAGNs show small scattering fractions (<0.5%), implying a buried AGN nature. (4) Comparison with the results obtained for Compton-thin AGNs suggests that the properties of these CTAGNs can be understood as a smooth extension from Compton-thin AGNs with heavier obscuration; we find no evidence that the bulk of the population of hard-X-ray-selected CTAGNs are different from less obscured objects.

  17. A case that underwent bilateral video-assisted thoracoscopic ...

    African Journals Online (AJOL)

    No Abstract Available A case that underwent bilateral video-assisted thoracoscopic surgical (VATS) biopsy combined with pneumonectomy is presented. The patient developed hypoxia during the contralateral VATS biopsy. His hypoxia was treated with positive expiratory pressure (PEEP) to the dependent lung and apneic ...

  18. Polarized gamma-rays with laser-Compton backscattering

    Energy Technology Data Exchange (ETDEWEB)

    Ohgaki, H.; Noguchi, T.; Sugiyama, S. [Electrotechnical Lab., Ibaraki (Japan)] [and others

    1995-12-31

    Polarized gamma-rays were generated through laser-Compton backscattering (LCS) of a conventional Nd:YAG laser with electrons circulating in the electron storage ring TERAS at Electrotechnical Laboratory. We measured the energy, the energy spread, and the yield of the gamma-rays to characterize our gamma-ray source. The gamma-ray energy can be varied by changing the energy of the electrons circulating the storage ring. In our case, the energy of electrons in the storage ring were varied its energy from 200 to 750 MeV. Consequently, we observed gamma-ray energies of 1 to 10 MeV with 1064 run laser photons. Furthermore, the gamma-ray energy was extended to 20 MeV by using the 2nd harmonic of the Nd:YAG laser. This shows a good agreement with theoretical calculation. The gamma-ray energy spread was also measured to be 1% FWHM for -1 MeV gamma-rays and to be 4% FWHM for 10 MeV gamma-rays with a narrow collimator that defined the scattering cone. The gamma-ray yield was 47.2 photons/mA/W/s. This value is consistent with a rough estimation of 59.5 photons/mA/W/s derived from theory. Furthermore, we tried to use these gamma-rays for a nuclear fluorescence experiment. If we use a polarized laser beam, we can easily obtain polarized gamma-rays. Elastically scattered photons from {sup 208} Pb were clearly measured with the linearly polarized gamma-rays, and we could assign the parity of J=1 states in the nucleus. We should emphasize that the polarized gamma-ray from LCS is quit useful in this field, because we can use highly, almost completely, polarized gamma-rays. We also use the LCS gamma-rays to measure the photon absorption coefficients. In near future, we will try to generate a circular polarized gamma-ray. We also have a plan to use an FEL, because it can produce intense laser photons in the same geometric configuration as the LCS facility.

  19. Compton Composites Late in the Early Universe

    Directory of Open Access Journals (Sweden)

    Frederick Mayer

    2014-07-01

    Full Text Available Beginning roughly two hundred years after the big-bang, a tresino phase transition generated Compton-scale composite particles and converted most of the ordinary plasma baryons into new forms of dark matter. Our model consists of ordinary electrons and protons that have been bound into mostly undetectable forms. This picture provides an explanation of the composition and history of ordinary to dark matter conversion starting with, and maintaining, a critical density Universe. The tresino phase transition started the conversion of ordinary matter plasma into tresino-proton pairs prior to the the recombination era. We derive the appropriate Saha–Boltzmann equilibrium to determine the plasma composition throughout the phase transition and later. The baryon population is shown to be quickly modified from ordinary matter plasma prior to the transition to a small amount of ordinary matter and a much larger amount of dark matter after the transition. We describe the tresino phase transition and the origin, quantity and evolution of the dark matter as it takes place from late in the early Universe until the present.

  20. Scattering and absorption differential cross sections for double ...

    Indian Academy of Sciences (India)

    as double photon Compton scattering have been measured as a function of independent final photon energy. ... of a brass pipe and fitted with aluminium windows on both the ends can be filled with a column of mercury ... thick iron and 1 mm thick aluminium, with iron facing lead to absorb K x-rays emitted by lead shielding.

  1. Characterization of Compton camera LaBr{sub 3} absorber detector

    Energy Technology Data Exchange (ETDEWEB)

    Marinsek, T.; Liprandi, S.; Bortfeldt, J.; Lang, C.; Lutter, R.; Dedes, G.; Parodi, K.; Thirolf, P.G. [LMU Munich, Garching (Germany); Aldawood, S. [LMU Munich, Garching (Germany); King Saud University, Riyadh (Saudi Arabia); Maier, L.; Gernhaeuser, R. [TU Munich, Garching (Germany); Kolff, H. van der [LMU Munich, Garching (Germany); TU Delft (Netherlands); Castelhano, I. [LMU Munich, Garching (Germany); University of Lisbon, Lisbon (Portugal); Schaart, D.R. [TU Delft (Netherlands)

    2015-07-01

    Detection of prompt γ rays from nuclear interactions between a particle beam and organic tissue using a Compton camera to determine the Bragg peak position is a promising way of ion-beam range verification in hadron therapy. The Compton camera consists of a stack of six double-sided Si-strip detectors acting as scatterers, while the other essential part - the absorber - is made of a LaBr{sub 3} monolithic scintillator crystal (50 x 50 x 30 mm{sup 3}) with reflective side-surface wrapping, offering excellent time and energy resolution. Scintillation light induced in the crystal is detected by a 256-fold segmented multi-anode PMT. Prerequisite to reconstruct the γ source position is the determination of the photon interaction position in the crystal by applying ''k-nearest neighbors'' algorithm (van Dam et al., Nuclear Science (2011)) using the reference library of light distributions, obtained by performing a 2D scan of the detector using a strong collimated {sup 137}Cs source. The status of the spatial resolution characterization is presented.

  2. Determining the covering factor of compton-thick active galactic nuclei with NuSTAR

    DEFF Research Database (Denmark)

    Brightman, M.; Balokovic, M.; Stern, D.

    2015-01-01

    covering factor. Determining this CT fraction is difficult, however, due to the extreme obscuration. With its spectral coverage at hard X-rays (>10 keV), Nuclear Spectroscopic Telescope Array (NuSTAR) is sensitive to the AGNs covering factor since Compton scattering of X-rays off optically thick material......The covering factor of Compton-thick (CT) obscuring material associated with the torus in active galactic nuclei (AGNs) is at present best understood through the fraction of sources exhibiting CT absorption along the line of sight (NH > 1.5 × 1024 cm-2) in the X-ray band, which reveals the average...... opening angle as a free parameter and aim to determine the covering factor of the CT gas in these sources individually. Across the sample we find mild to heavy CT columns, with NH measured from 1024 to 1026 cm-2, and a wide range of covering factors, where individual measurements range from 0.2 to 0.9. We...

  3. Compton imaging tomography for nondestructive evaluation of large multilayer aircraft components and structures

    Science.gov (United States)

    Romanov, Volodymyr; Grubsky, Victor; Zahiri, Feraidoon

    2017-02-01

    We present a novel NDT/NDE tool for non-contact, single-sided 3D inspection of aerospace components, based on Compton Imaging Tomography (CIT) technique, which is applicable to large, non-uniform, and/or multilayer structures made of composites or lightweight metals. CIT is based on the registration of Compton-scattered X-rays, and permits the reconstruction of the full 3D (tomographic) image of the inspected objects. Unlike conventional computerized tomography (CT), CIT requires only single-sided access to objects, and therefore can be applied to large structures without their disassembly. The developed tool provides accurate detection, identification, and precise 3D localizations and measurements of any possible internal and surface defects (corrosions, cracks, voids, delaminations, porosity, and inclusions), and also disbonds, core and skin defects, and intrusion of foreign fluids (e.g., fresh and salt water, oil) inside of honeycomb sandwich structures. The NDE capabilities of the system were successfully demonstrated on various aerospace structure samples provided by several major aerospace companies. Such a CIT-based tool can detect and localize individual internal defects with dimensions about 1-2 mm3, and honeycomb disbond defects less than 6 mm by 6 mm area with the variations in the thickness of the adhesive by 100 m. Current maximum scanning speed of aircraft/spacecraft structures is about 5-8 min/ft2 (50-80 min/m2).

  4. NUTRITION SUPPORT COMPLICATIONS IN PATIENT WHO UNDERWENT CARDIAC SURGERY

    OpenAIRE

    Krdžalić, Alisa; Kovčić, Jasmina; Krdžalić, Goran; Jahić, Elmir

    2016-01-01

    Background: The nutrition support complications after cardiac surgery should be detected and treated on time. Aim: To show the incidence and type of nutritional support complication in patients after cardiac surgery. Methods: The prospective study included 415 patients who underwent cardiac surgery between 2010 and 2013 in Clinic for Cardiovascular Disease of University Clinical Center Tuzla. Complications of the delivery system for nutrition support (NS) and nutrition itself were analy...

  5. Balloon flight test of a Compton telescope based on scintillators with silicon photomultiplier readouts

    Science.gov (United States)

    Bloser, P. F.; Legere, J. S.; Bancroft, C. M.; Ryan, J. M.; McConnell, M. L.

    2016-03-01

    We present the results of the first high-altitude balloon flight test of a concept for an advanced Compton telescope making use of modern scintillator materials with silicon photomultiplier (SiPM) readouts. There is a need in the fields of high-energy astronomy and solar physics for new medium-energy gamma-ray ( 0.4-10 MeV) detectors capable of making sensitive observations of both line and continuum sources over a wide dynamic range. A fast scintillator-based Compton telescope with SiPM readouts is a promising solution to this instrumentation challenge, since the fast response of the scintillators permits both the rejection of background via time-of-flight (ToF) discrimination and the ability to operate at high count rates. The Solar Compton Telescope (SolCompT) prototype presented here was designed to demonstrate stable performance of this technology under balloon-flight conditions. The SolCompT instrument was a simple two-element Compton telescope, consisting of an approximately one-inch cylindrical stilbene crystal for a scattering detector and a one-inch cubic LaBr3:Ce crystal for a calorimeter detector. Both scintillator detectors were read out by 2×2 arrays of Hamamatsu S11828-3344 MPPC devices. Custom front-end electronics provided optimum signal rise time and linearity, and custom power supplies automatically adjusted the SiPM bias voltage to compensate for temperature-induced gain variations. A tagged calibration source, consisting of 240 nCi of 60Co embedded in plastic scintillator, was placed in the field of view and provided a known source of gamma rays to measure in flight. The SolCompT balloon payload was launched on 24 August 2014 from Fort Sumner, NM, and spent 3.75 h at a float altitude of 123,000 ft. The instrument performed well throughout the flight. After correcting for small ( 10%) residual gain variations, we measured an in-flight ToF resolution of 760 ps (FWHM). Advanced scintillators with SiPM readouts continue to show great promise for

  6. Balloon flight test of a Compton telescope based on scintillators with silicon photomultiplier readouts

    International Nuclear Information System (INIS)

    Bloser, P.F.; Legere, J.S.; Bancroft, C.M.; Ryan, J.M.; McConnell, M.L.

    2016-01-01

    We present the results of the first high-altitude balloon flight test of a concept for an advanced Compton telescope making use of modern scintillator materials with silicon photomultiplier (SiPM) readouts. There is a need in the fields of high-energy astronomy and solar physics for new medium-energy gamma-ray (~0.4–10 MeV) detectors capable of making sensitive observations of both line and continuum sources over a wide dynamic range. A fast scintillator-based Compton telescope with SiPM readouts is a promising solution to this instrumentation challenge, since the fast response of the scintillators permits both the rejection of background via time-of-flight (ToF) discrimination and the ability to operate at high count rates. The Solar Compton Telescope (SolCompT) prototype presented here was designed to demonstrate stable performance of this technology under balloon-flight conditions. The SolCompT instrument was a simple two-element Compton telescope, consisting of an approximately one-inch cylindrical stilbene crystal for a scattering detector and a one-inch cubic LaBr 3 :Ce crystal for a calorimeter detector. Both scintillator detectors were read out by 2×2 arrays of Hamamatsu S11828-3344 MPPC devices. Custom front-end electronics provided optimum signal rise time and linearity, and custom power supplies automatically adjusted the SiPM bias voltage to compensate for temperature-induced gain variations. A tagged calibration source, consisting of ~240 nCi of 60 Co embedded in plastic scintillator, was placed in the field of view and provided a known source of gamma rays to measure in flight. The SolCompT balloon payload was launched on 24 August 2014 from Fort Sumner, NM, and spent ~3.75 h at a float altitude of ~123,000 ft. The instrument performed well throughout the flight. After correcting for small (~10%) residual gain variations, we measured an in-flight ToF resolution of ~760 ps (FWHM). Advanced scintillators with SiPM readouts continue to show great

  7. Balloon flight test of a Compton telescope based on scintillators with silicon photomultiplier readouts

    Energy Technology Data Exchange (ETDEWEB)

    Bloser, P.F., E-mail: Peter.Bloser@unh.edu; Legere, J.S.; Bancroft, C.M.; Ryan, J.M.; McConnell, M.L.

    2016-03-11

    We present the results of the first high-altitude balloon flight test of a concept for an advanced Compton telescope making use of modern scintillator materials with silicon photomultiplier (SiPM) readouts. There is a need in the fields of high-energy astronomy and solar physics for new medium-energy gamma-ray (~0.4–10 MeV) detectors capable of making sensitive observations of both line and continuum sources over a wide dynamic range. A fast scintillator-based Compton telescope with SiPM readouts is a promising solution to this instrumentation challenge, since the fast response of the scintillators permits both the rejection of background via time-of-flight (ToF) discrimination and the ability to operate at high count rates. The Solar Compton Telescope (SolCompT) prototype presented here was designed to demonstrate stable performance of this technology under balloon-flight conditions. The SolCompT instrument was a simple two-element Compton telescope, consisting of an approximately one-inch cylindrical stilbene crystal for a scattering detector and a one-inch cubic LaBr{sub 3}:Ce crystal for a calorimeter detector. Both scintillator detectors were read out by 2×2 arrays of Hamamatsu S11828-3344 MPPC devices. Custom front-end electronics provided optimum signal rise time and linearity, and custom power supplies automatically adjusted the SiPM bias voltage to compensate for temperature-induced gain variations. A tagged calibration source, consisting of ~240 nCi of {sup 60}Co embedded in plastic scintillator, was placed in the field of view and provided a known source of gamma rays to measure in flight. The SolCompT balloon payload was launched on 24 August 2014 from Fort Sumner, NM, and spent ~3.75 h at a float altitude of ~123,000 ft. The instrument performed well throughout the flight. After correcting for small (~10%) residual gain variations, we measured an in-flight ToF resolution of ~760 ps (FWHM). Advanced scintillators with SiPM readouts continue to show

  8. Comptonization of gamma rays by cold electrons

    International Nuclear Information System (INIS)

    Xu, Yueming; Ross, R.R.; Mccray, R.

    1991-01-01

    An analytic method is developed for calculating the emergent spectrum of gamma-rays and X-rays scattered in a homogeneous medium with low-temperature electrons. The Klein-Nishina corrections of the scattering cross section and absorption processes are taken in account. The wavelength relaxation and the spatial diffusion problems are solved separately, and the emergent spectrum is calculated by convolving the evolution function of the spectrum in an infinite medium with the photon luminosity resulting from the spatial diffusion in a finite sphere. The analytic results are compared with that of Monte Carlo calculations and it is concluded that the analytic result is quite accurate. 9 refs

  9. Fast analytical scatter estimation using graphics processing units.

    Science.gov (United States)

    Ingleby, Harry; Lippuner, Jonas; Rickey, Daniel W; Li, Yue; Elbakri, Idris

    2015-01-01

    To develop a fast patient-specific analytical estimator of first-order Compton and Rayleigh scatter in cone-beam computed tomography, implemented using graphics processing units. The authors developed an analytical estimator for first-order Compton and Rayleigh scatter in a cone-beam computed tomography geometry. The estimator was coded using NVIDIA's CUDA environment for execution on an NVIDIA graphics processing unit. Performance of the analytical estimator was validated by comparison with high-count Monte Carlo simulations for two different numerical phantoms. Monoenergetic analytical simulations were compared with monoenergetic and polyenergetic Monte Carlo simulations. Analytical and Monte Carlo scatter estimates were compared both qualitatively, from visual inspection of images and profiles, and quantitatively, using a scaled root-mean-square difference metric. Reconstruction of simulated cone-beam projection data of an anthropomorphic breast phantom illustrated the potential of this method as a component of a scatter correction algorithm. The monoenergetic analytical and Monte Carlo scatter estimates showed very good agreement. The monoenergetic analytical estimates showed good agreement for Compton single scatter and reasonable agreement for Rayleigh single scatter when compared with polyenergetic Monte Carlo estimates. For a voxelized phantom with dimensions 128 × 128 × 128 voxels and a detector with 256 × 256 pixels, the analytical estimator required 669 seconds for a single projection, using a single NVIDIA 9800 GX2 video card. Accounting for first order scatter in cone-beam image reconstruction improves the contrast to noise ratio of the reconstructed images. The analytical scatter estimator, implemented using graphics processing units, provides rapid and accurate estimates of single scatter and with further acceleration and a method to account for multiple scatter may be useful for practical scatter correction schemes.

  10. A computer program for processing experimental Compton profile of solids and liquids

    International Nuclear Information System (INIS)

    Das, G.P.

    1984-01-01

    A computer program COMPRO has been developed for processing experimental Compton profile data of solids and liquids generated by inelastic gamma ray scattering using a solid state detector and a multichannel analyser. It also calculates the fourier transform of the profile yielding the one electron autocorrelation function in position space. The theory behind the method of calculation is outlined and the various data processing steps needed to be applied on the raw experimental data have been discussed in detail. A flow chart of the program is given and the various subroutines of the program, method of feeding the input data and the method of presenting the final result are briefly described. The procedure is illustrated by measurement on a polycrystalline sample of manganese. The actual listing of the program along with the test run input data and the test run output data is also given. (M.G.B.)

  11. A flying spot x-ray system for Compton backscatter imaging

    International Nuclear Information System (INIS)

    Herr, M.D.; McInerney, J.J.; Copenhaver, G.L.; Lamser, D.G.

    1994-01-01

    A Compton x-ray backscatter imaging (CBI) system using a single detector and a mechanically rastered ''flying spot'' x-ray beam has been designed, built, and tested. While retaining the essential noninvasive imaging capability of previous multiple detector CBI devices, this single detector system incorporates several advances over earlier CBI devices: more efficient detection of scattered x-rays, reduced x-ray exposure, and a simplified scan protocol more suitable for use with humans. This new CBI system also has specific design features to permit automating data acquisition from multiple two-dimensional image planes for integration into a 3-D dynamic surface image. A simulated multislice scan study of a human thorax phantom provided x-ray dosimetry data verifying a very low x-ray dose delivered by this imaging device. Validation experiments with mechanical models show that surface displacement of typical heart beam frequencies can be measured to the nearest 0.1 mm (SD)

  12. The synchrotron-self-Compton process in spherical geometries. I - Theoretical framework

    Science.gov (United States)

    Band, D. L.; Grindlay, J. E.

    1985-01-01

    Both spatial and spectral accuracies are stressed in the present method for the calculation of the synchrotron-self-Compton model in spherical geometries, especially in the partially opaque regime of the synchrotron spectrum of inhomogeneous sources that can span a few frequency decades and contribute a significant portion of the scattered flux. A formalism is developed that permits accurate calculation of incident photon density throughout an optically thin sphere. An approximation to the Klein-Nishina cross section is used to model the effects of variable electron and incident photon cutoffs, as well as the decrease in the cross section at high energies. General results are derived for the case of inhomogeneous sources with power law profiles in both electron density and magnetic field.

  13. X-band RF Photoinjector for Laser Compton X-ray and Gamma-ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, R. A. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Anderson, G. G. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Anderson, S. G. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Gibson, D. J. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Barty, C. J. [Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States)

    2015-05-06

    Extremely bright narrow bandwidth gamma-ray sources are expanding the application of accelerator technology and light sources in new directions. An X-band test station has been commissioned at LLNL to develop multi-bunch electron beams. This multi-bunch mode will have stringent requirements for the electron bunch properties including low emittance and energy spread, but across multiple bunches. The test station is a unique facility featuring a 200 MV/m 5.59 cell X-band photogun powered by a SLAC XL4 klystron driven by a Scandinova solid-state modulator. This paper focuses on its current status including the generation and initial characterization of first electron beam. Design and installation of the inverse-Compton scattering interaction region and upgrade paths will be discussed along with future applications.

  14. Compton-thick AGN at high and low redshift

    Science.gov (United States)

    Akylas, A.; Georgantopoulos, I.; Corral, A.; Ranalli, P.; Lanzuisi, G.

    2017-10-01

    The most obscured sources detected in X-ray surveys, the Compton-thick AGN present great interest both because they represent the hidden side of accretion but also because they may signal the AGN birth. We analyse the NUSTAR observations from the serendipitous observations in order to study the Compton-thick AGN at the deepest possible ultra-hard band (>10 keV). We compare our results with our SWIFT/BAT findings in the local Universe, as well as with our results in the CDFS and COSMOS fields. We discuss the comparison with X-ray background synthesis models finding that a low fraction of Compton-thick sources (about 15 per cent of the obscured population) is compatible with both the 2-10keV band results and those at harder energies.

  15. Resonant Compton Upscattering Models of Magnetar Hard X-ray Emission and Polarization

    Science.gov (United States)

    Baring, Matthew G.; Wadiasingh, Zorawar; Gonthier, Peter L.; Kust Harding, Alice

    2017-08-01

    Non-thermal quiescent X-ray emission extending between 10 keV and around 150 keV has been seen in about 10 magnetars by RXTE, INTEGRAL, Suzaku and Fermi-GBM. For inner magnetospheric models of such hard X-ray signals, resonant Compton upscattering is anticipated to be the most efficient process for generating the continuum radiation. This is because the scattering becomes resonant at the cyclotron frequency, and the effective cross section exceeds the classical Thomson value by over two orders of magnitude. We present angle-dependent hard X-ray upscattering model spectra for uncooled monoenergetic relativistic electrons injected in inner regions of pulsar magnetospheres. These spectra are integrated over closed field lines and obtained for different observing perspectives. The spectral cut-off energies are critically dependent on the observer viewing angles and electron Lorentz factor. We find that electrons with energies less than around 15 MeV will emit most of their radiation below 250 keV, consistent with the observed turnovers in magnetar hard X-ray tails. Moreover, electrons of higher energy still emit most of the radiation below around 1 MeV, except for quasi-equatorial emission locales for select pulses phases. In such cases, attenuation mechanisms such as pair creation will be prolific, thereby making it difficult to observe signals extending into the Fermi-LAT band. Our spectral computations use new state-of-the-art, spin-dependent formalism for the QED Compton scattering cross section in strong magnetic fields. The emission exhibits strong polarization above around 30 keV that is anticipated to be dependent on pulse phase, thereby defining science agendas for future hard X-ray polarimeters.

  16. Inverse Compton Light Source: A Compact Design Proposal

    Science.gov (United States)

    Deitrick, Kirsten Elizabeth

    In the last decade, there has been an increasing demand for a compact Inverse Compton Light Source (ICLS) which is capable of producing high-quality X-rays by colliding an electron beam and a high-quality laser. It is only in recent years when both SRF and laser technology have advanced enough that compact sources can approach the quality found at large installations such as the Advanced Photon Source at Argonne National Laboratory. Previously, X-ray sources were either high flux and brilliance at a large facility or many orders of magnitude lesser when produced by a bremsstrahlung source. A recent compact source was constructed by Lyncean Technologies using a storage ring to produce the electron beam used to scatter the incident laser beam. By instead using a linear accelerator system for the electron beam, a significant increase in X-ray beam quality is possible, though even subsequent designs also featuring a storage ring offer improvement. Preceding the linear accelerator with an SRF reentrant gun allows for an extremely small transverse emittance, increasing the brilliance of the resulting X-ray source. In order to achieve sufficiently small emittances, optimization was done regarding both the geometry of the gun and the initial electron bunch distribution produced off the cathode. Using double-spoke SRF cavities to comprise the linear accelerator allows for an electron beam of reasonable size to be focused at the interaction point, while preserving the low emittance that was generated by the gun. An aggressive final focusing section following the electron beam's exit from the accelerator produces the small spot size at the interaction point which results in an X-ray beam of high flux and brilliance. Taking all of these advancements together, a world class compact X-ray source has been designed. It is anticipated that this source would far outperform the conventional bremsstrahlung and many other compact ICLSs, while coming closer to performing at the levels

  17. Inverse compton light source: a compact design proposal

    Energy Technology Data Exchange (ETDEWEB)

    Deitrick, Kirsten Elizabeth [Old Dominion Univ., Norfolk, VA (United States); Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2017-05-01

    In the last decade, there has been an increasing demand for a compact Inverse Compton Light Source (ICLS) which is capable of producing high-quality X-rays by colliding an electron beam and a high-quality laser. It is only in recent years when both SRF and laser technology have advanced enough that compact sources can approach the quality found at large installations such as the Advanced Photon Source at Argonne National Laboratory. Previously, X-ray sources were either high flux and brilliance at a large facility or many orders of magnitude lesser when produced by a bremsstrahlung source. A recent compact source was constructed by Lyncean Technologies using a storage ring to produce the electron beam used to scatter the incident laser beam. By instead using a linear accelerator system for the electron beam, a significant increase in X-ray beam quality is possible, though even subsequent designs also featuring a storage ring offer improvement. Preceding the linear accelerator with an SRF reentrant gun allows for an extremely small transverse emittance, increasing the brilliance of the resulting X-ray source. In order to achieve sufficiently small emittances, optimization was done regarding both the geometry of the gun and the initial electron bunch distribution produced off the cathode. Using double-spoke SRF cavities to comprise the linear accelerator allows for an electron beam of reasonable size to be focused at the interaction point, while preserving the low emittance that was generated by the gun. An aggressive final focusing section following the electron beam's exit from the accelerator produces the small spot size at the interaction point which results in an X-ray beam of high flux and brilliance. Taking all of these advancements together, a world class compact X-ray source has been designed. It is anticipated that this source would far outperform the conventional bremsstrahlung and many other compact ICLSs, while coming closer to performing at the

  18. γ-ray compton profiles of liquid and crystalline aluminum

    International Nuclear Information System (INIS)

    Honda, Toshihisa; Itoh, Fumitake; Suzuki, Kenji

    1979-01-01

    Compton profiles of liquid and crystalline aluminum metal have been measured using 59.54 keV γ-rays emitted from 241 Am and Ge(Li) solid state detectors. The difference of the Compton profile between the liquid and crystalline aluminum has been found and can be qualitatively understood in terms of the change in the electronic density upon melting. The experimental profile of crystalline aluminum is in good agreement with the result of the LCAO band calculation, while the profile of liquid aluminum is in poor agreement with the free electron model and the Green function method. (author)

  19. A counting silicon microstrip detector for precision compton polarimetry

    CERN Document Server

    Doll, D W; Hillert, W; Krüger, H; Stammschroer, K; Wermes, N

    2002-01-01

    A detector for the detection of laser photons backscattered off an incident high-energy electron beam for precision Compton polarimetry in the 3.5 GeV electron stretcher ring ELSA at Bonn University has been developed using individual photon counting. The photon counting detector is based on a silicon microstrip detector system using dedicated ASIC chips. The produced hits by the pair converted Compton photons are accumulated rather than individually read out. A transverse profile displacement can be measured with mu m accuracy rendering a polarization measurement of the order of 1% on the time scale of 10-15 min possible.

  20. Pigmented Villonodular Synovitis in a Patient who Underwent Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Nevzat Dabak

    2014-09-01

    Full Text Available Pigmented villonodular synovitis (PVNS is a rare, benign, but a locally aggressive tumor. It is characterized by the proliferation of synovial membrane, but it can also be seen in tendon sheaths and bursae. Clinical presentation of solitary lesions include compression and locking of the joint suggesting loose bodies in the joint and a subsequent findings of an effusion, whereas diffuse lesions manifest with pain and chronic swelling. In this article, we presented a curious case of PVNS in a female patient who have been followed up due to an acetabular cystic lesion. She underwent total hip arthroplasty for severe osteoarthritis of the hip joint and associated pain. The diagnosis of PVNS was established intraoperatively. (The Me­di­cal Bul­le­tin of Ha­se­ki 2014; 52: 235-7

  1. ALGORITHM FOR MANAGEMENT OF HYPERTENSIVE PATIENTS UNDERWENT UROLOGY INTERVENTIONS

    Directory of Open Access Journals (Sweden)

    S. S. Davydova

    2015-09-01

    Full Text Available Aim. To study the efficacy of cardiovascular non-invasive complex assessment and pre-operative preparation in hypertensive patients needed in surgical treatment of urology dis- eases.Material and methods. Males (n=883, aged 40 to 80 years were included into the study. The main group consisted of patients that underwent laparotomic nephrectomy (LTN group; n=96 and patients who underwent laparoscopic nephrectomy (LSN group; n=53. Dynamics of ambulatory blood pressure monitoring (ABPM data was analyzed in these groups in the immediate postoperative period. The efficacy of a package of non-invasive methods for cardiovascular system assessment was studied. ABPM was performed after nephrectomy (2-nd and 10-th days after surgery in patients with complaints of vertigo episodes or intense general weakness to correct treatment.Results. In LTN group hypotension episodes or blood pressure (BP elevations were observed in 20 (20.8% and 22 (22.9% patients, respectively, on the 2-nd day after the operation. These complications required antihypertensive treatment correction. Patients with hypotension episodes were significantly older than patients with BP elevation and had significantly lower levels of 24-hour systolic BP, night diastolic BP and minimal night systolic BP. Re-adjustment of antihypertensive treatment on the 10-th postoperative day was required to 2 (10% patients with hypotension episodes and to 1 (4.5% patient with BP elevation. Correction of antihypertensive therapy was required to all patients in LSN group on the day 2, and to 32 (60.4% patients on the 10-th day after the operation. Reduction in the incidence of complications (from 1.2% in 2009 to 0.3% in 2011, p<0.001 was observed during the application of cardiovascular non-invasive complex assessment and preoperative preparation in hypertensive patients.Conclusion. The elaborated management algorithm for patients with concomitant hypertension is recommended to reduce the cardiovascular

  2. ALGORITHM FOR MANAGEMENT OF HYPERTENSIVE PATIENTS UNDERWENT UROLOGY INTERVENTIONS

    Directory of Open Access Journals (Sweden)

    S. S. Davydova

    2013-01-01

    Full Text Available Aim. To study the efficacy of cardiovascular non-invasive complex assessment and pre-operative preparation in hypertensive patients needed in surgical treatment of urology dis- eases.Material and methods. Males (n=883, aged 40 to 80 years were included into the study. The main group consisted of patients that underwent laparotomic nephrectomy (LTN group; n=96 and patients who underwent laparoscopic nephrectomy (LSN group; n=53. Dynamics of ambulatory blood pressure monitoring (ABPM data was analyzed in these groups in the immediate postoperative period. The efficacy of a package of non-invasive methods for cardiovascular system assessment was studied. ABPM was performed after nephrectomy (2-nd and 10-th days after surgery in patients with complaints of vertigo episodes or intense general weakness to correct treatment.Results. In LTN group hypotension episodes or blood pressure (BP elevations were observed in 20 (20.8% and 22 (22.9% patients, respectively, on the 2-nd day after the operation. These complications required antihypertensive treatment correction. Patients with hypotension episodes were significantly older than patients with BP elevation and had significantly lower levels of 24-hour systolic BP, night diastolic BP and minimal night systolic BP. Re-adjustment of antihypertensive treatment on the 10-th postoperative day was required to 2 (10% patients with hypotension episodes and to 1 (4.5% patient with BP elevation. Correction of antihypertensive therapy was required to all patients in LSN group on the day 2, and to 32 (60.4% patients on the 10-th day after the operation. Reduction in the incidence of complications (from 1.2% in 2009 to 0.3% in 2011, p<0.001 was observed during the application of cardiovascular non-invasive complex assessment and preoperative preparation in hypertensive patients.Conclusion. The elaborated management algorithm for patients with concomitant hypertension is recommended to reduce the cardiovascular

  3. Determination of electron beam polarization using electron detector in Compton polarimeter with less than 1% statistical and systematic uncertainty

    Energy Technology Data Exchange (ETDEWEB)

    Narayan, Amrendra [Mississippi State Univ., Mississippi State, MS (United States)

    2015-05-01

    The Q-weak experiment aims to measure the weak charge of proton with a precision of 4.2%. The proposed precision on weak charge required a 2.5% measurement of the parity violating asymmetry in elastic electron - proton scattering. Polarimetry was the largest experimental contribution to this uncertainty and a new Compton polarimeter was installed in Hall C at Jefferson Lab to make the goal achievable. In this polarimeter the electron beam collides with green laser light in a low gain Fabry-Perot Cavity; the scattered electrons are detected in 4 planes of a novel diamond micro strip detector while the back scattered photons are detected in lead tungstate crystals. This diamond micro-strip detector is the first such device to be used as a tracking detector in a nuclear and particle physics experiment. The diamond detectors are read out using custom built electronic modules that include a preamplifier, a pulse shaping amplifier and a discriminator for each detector micro-strip. We use field programmable gate array based general purpose logic modules for event selection and histogramming. Extensive Monte Carlo simulations and data acquisition simulations were performed to estimate the systematic uncertainties. Additionally, the Moller and Compton polarimeters were cross calibrated at low electron beam currents using a series of interleaved measurements. In this dissertation, we describe all the subsystems of the Compton polarimeter with emphasis on the electron detector. We focus on the FPGA based data acquisition system built by the author and the data analysis methods implemented by the author. The simulations of the data acquisition and the polarimeter that helped rigorously establish the systematic uncertainties of the polarimeter are also elaborated, resulting in the first sub 1% measurement of low energy (?1 GeV) electron beam polarization with a Compton electron detector. We have demonstrated that diamond based micro-strip detectors can be used for tracking in a

  4. On a low intensity 241Am Compton spectrometer for measurement ...

    Indian Academy of Sciences (India)

    Phys. 111,. 163 (1999). [6] N I Papanicolaou, N C Bacalis and D A Papaconstantopoulos, Handbook of calcu- lated electron momentum distributions, Compton profiles and X-ray form factors of elemental solids (CRC Press, London, 1991). [7] V R Saunders, R Dovesi, C Roetti, R Orlando, C M Zicovich-Wilson, N M Harrison, ...

  5. Simple modification of Compton polarimeter to redirect synchrotron radiation

    Directory of Open Access Journals (Sweden)

    J. Benesch

    2015-11-01

    Full Text Available Synchrotron radiation produced as an electron beam passes through a bending magnet is a significant source of background in many experiments. Using modeling, we show that simple modifications of the magnet geometry can reduce this background by orders of magnitude in some circumstances. Specifically, we examine possible modifications of the four dipole magnets used in Jefferson Lab’s Hall A Compton polarimeter chicane. This Compton polarimeter has been a crucial part of experiments with polarized beams and the next generation of experiments will utilize increased beam energies, up to 11 GeV, requiring a corresponding increase in Compton dipole field to 1.5 T. In consequence, the synchrotron radiation (SR from the dipole chicane will be greatly increased. Three possible modifications of the chicane dipoles are studied; each design moves about 2% of the integrated bending field to provide a gentle bend in critical regions along the beam trajectory which, in turn, greatly reduces the synchrotron radiation within the acceptance of the Compton polarimeter photon detector. Each of the modifications studied also softens the SR energy spectrum at the detector sufficiently to allow shielding with 5 mm of lead. Simulations show that these designs are each capable of reducing the background signal due to SR by three orders of magnitude. The three designs considered vary in their need for vacuum vessel changes and in their effectiveness.

  6. Electronic structure of hafnium: A Compton profile study

    Indian Academy of Sciences (India)

    In this paper, we report the first-ever isotropic Compton profile of hafnium measured at an intermediate resolution, with 661.65 keV -radiation. To compare our experimental data, the theoretical computations have also been carried out within the framework of pseudopotential using CRYSTAL03 code and the ...

  7. Strong anisotropy in the low temperature Compton profiles of ...

    Indian Academy of Sciences (India)

    Compton profiles of momentum distribution of conduction electrons in the orthorhombic phase of -Ga metal at low temperature are calculated in the band model for the three crystallographic directions (100), (010), and (001). Unlike the results at room temperature, previously reported by Lengeler, Lasser and Mair, the ...

  8. Electronic properties and Compton profiles of silver iodide

    Indian Academy of Sciences (India)

    We have carried out an extensive study of electronic properties of silver iodide in - and -phases. The theoretical Compton profiles, energy bands, density of states and anisotropies in momentum densities are computed using density functional theories. We have also employed full-potential linearized augmented ...

  9. Compton-thick AGN in the 3XMM spectral survey

    Science.gov (United States)

    Georgantopoulos, I.; Corral, A.; Watson, M.; Rosen, S.

    2014-07-01

    In the framework of an ESA Prodex project, we have derived X-ray spectral fits for a large number (120,000) of 3XMM sources. We focus our study on the 120 square degrees that overlap with the SDSS survey. For about 1,100 AGN there are spectroscopic redsifts available. We automatically select candidate Compton-thick sources using simple spectral models. Various selection criteria are applied including a) a high equivalent width FeK line b) a flat spectrum with a photon index of 1.4 or lower at the 90% confidence level or at higher redshift an absorption turnover consistent with a column density of logNh=24. We find 30 candidate Compton-thick sources. More detailed spectral models are applied trying to secure the Compton-thick nature of these sources. We compare our findings with X-ray background synthesis models as well as with Compton-thick surveys in the COSMOS and XMM/CDFS areas.

  10. Momentum densities and Compton profiles of alkali-metal atoms

    Indian Academy of Sciences (India)

    Home; Journals; Pramana – Journal of Physics; Volume 60; Issue 3 ... Quantum defect theory; wave functions of alkali-metal atoms; momentum properties. ... to study the momentum properties of atoms from 3Li to 37Rb. The numerical results obtained for the momentum density, moments of momentum density and Compton ...

  11. On a low intensity 241Am Compton spectrometer for measurement ...

    Indian Academy of Sciences (India)

    In this paper, a new design and construction of a low intensity (100 mCi) 241Am -ray Compton spectrometer is presented. The planar spectrometer is based on a small disc source with the shortest geometry. Measurement of the momentum density of polycrystalline Al is used to evaluate the performance of the new design.

  12. Strong anisotropy in the low temperature Compton profiles of ...

    Indian Academy of Sciences (India)

    Abstract. Compton profiles of momentum distribution of conduction electrons in the orthorhom- bic phase of α-Ga metal at low temperature are calculated in the band model for the three crys- tallographic directions (100), (010), and (001). Unlike the results at room temperature, previously reported by Lengeler, Lasser and ...

  13. On a low intensity 241 Am Compton spectrometer for measurement ...

    Indian Academy of Sciences (India)

    In this paper, a new design and construction of a low intensity (100 mCi) 241Am -ray Compton spectrometer is presented. The planar spectrometer is based on a small disc source with the shortest geometry. Measurement of the momentum density of polycrystalline Al is used to evaluate the performance of the new design.

  14. Gamma-spectrometry with Compton suppressed detectors arrays

    International Nuclear Information System (INIS)

    Schueck, C.; Hannachi, F.; Chapman, R.

    1985-01-01

    Recent results of experiments performed with two different Compton-suppressed detectors arrays in Daresbury and Berkeley (/sup 163,164/Yb and 154 Er, respectively), are presented together with a brief description of the national French array presently under construction in Strasbourg. 25 refs., 15 figs

  15. Strong anisotropy in the low temperature Compton profiles of ...

    Indian Academy of Sciences (India)

    B P PANDA and N C MOHAPATRA£. Department of Physics, Chikiti Mahavidyalaya, Chikiti 761 010, India. £Department of Physics, Berhampur University, Berhampur 760 007, India. MS received 12 April 2001; revised 1 September 2001. Abstract. Compton profiles of momentum distribution of conduction electrons in the ...

  16. Frequency of Helicobacter pylori in patients underwent endoscopy

    Directory of Open Access Journals (Sweden)

    Ahmet Tay

    2012-06-01

    Full Text Available Objectives: The aim of this study was to investigate thefrequency of Helicobacter pylori in patients underwent endoscopyeastern Anatolia.Materials and methods: The patients whose endoscopicantral biopsies were taken for any reason in our endoscopyunit in February-June 2010 period were includedand retrospectively investigated. The frequency of Helicobacterpylori was determined as separating the patientsaccording to general, sex and the age groups. Antral biopsieswere stained with hematoxylin-eosin and modified giemsamethod and examined under light microscope andreported as (+ mild, (++ moderate, (+++ severe positiveaccording to their intensities.Results: Biopsy specimens of 1298 patients were includedinto the study. The mean age was 47.5 ± 17.5 years(range 14-88 and 607 of these patients (47% were male.Histopathological evaluation revealed that, 918 of the patientswere (71% positive and 379 (29% were negativefor Helicobacter pylori. Approximately 60% of our patientshad mild, 29% had moderate and 11% had severe positivityfor Helicobacter pylori. No significant difference wasfound in the frequency of Helicobacter pylori betweenwomen and men. The frequencies of Helicobacter pyloriwere 73.2%, 71.5%, 68.6% and 70.4%, respectively, inthe age groups of 14-30 years, 31-45 years, 46-60 yearsand 61-88 years.Conclusion: The frequency of Helicobacter pylori was71% in Eastern Anatolia Region. No statistically significantdifference was found between genders and agegroups in term of the frequency of Helicobacter pylori.

  17. Measurement of position dependence of spectral distribution in primary X-ray beam of CT system using compton spectroscopy

    International Nuclear Information System (INIS)

    Matsumoto, Masao; Maeda, Koji; Maeda, Koji

    2005-01-01

    Our purpose is to acquire the diagnostic x-ray spectra of the CT system easily under clinical conditions by Compton scatter spectroscopy using a high resolution Schottky CdTe detector recently developed and to estimate the quality and quantity of these spectra compared the relative exposure measured using an ionization chamber with curves measured by the reconstructed spectra. Although the spectral broadening and the fluctuation were slightly shown, the errors of the relative exposure were under 10%. Though the experimental arrangement of this method is so easy and reconstructed algorithm is simple, these results suggested that this method is little influenced by the variation of dose rates or property of the incident x rays. We therefore propose that the Compton scatter spectroscopy with the newly developed Schottky CdTe detector is suitable for measuring the diagnostic x-ray spectra of the CT system under the clinical conditions and useful for quality assurance and quality control of the clinical x-ray CT system. (author)

  18. Scattered Radiation Emission Imaging: Principles and Applications

    Directory of Open Access Journals (Sweden)

    M. K. Nguyen

    2011-01-01

    Full Text Available Imaging processes built on the Compton scattering effect have been under continuing investigation since it was first suggested in the 50s. However, despite many innovative contributions, there are still formidable theoretical and technical challenges to overcome. In this paper, we review the state-of-the-art principles of the so-called scattered radiation emission imaging. Basically, it consists of using the cleverly collected scattered radiation from a radiating object to reconstruct its inner structure. Image formation is based on the mathematical concept of compounded conical projection. It entails a Radon transform defined on circular cone surfaces in order to express the scattered radiation flux density on a detecting pixel. We discuss in particular invertible cases of such conical Radon transforms which form a mathematical basis for image reconstruction methods. Numerical simulations performed in two and three space dimensions speak in favor of the viability of this imaging principle and its potential applications in various fields.

  19. Experimental investigations of multiple scattering of 662keV gamma photons in elements and binary alloys.

    Science.gov (United States)

    Singh, Gurvinderjit; Singh, Manpreet; Sandhu, B S; Singh, Bhajan

    2008-08-01

    The energy, intensity and angular distributions of multiple scattering of 662 keV gamma photons, emerging from targets of pure elements and binary alloys, are observed as a function of target thickness in reflection and transmission geometries. The observed spectra recorded by a properly shielded NaI (Tl) scintillation detector, in addition to singly scattered events, consist of photons scattered more than once for thick targets. To extract the contribution of multiply scattered photons from the measured spectra, a singly scattered distribution is reconstructed analytically. We observe that the numbers of multiply scattered events increase with increase in target thickness, and saturate for a particular thickness called saturation thickness. The saturation thickness decreases with increasing atomic number. The multiple scattering, an interfering background noise in Compton profiles and Compton cross-section measurements, has been successfully used as a new technique to assign the "effective atomic number" to binary alloys. Monte Carlo calculations support the present experimental results.

  20. Compton DIV: Using a Compton-Based Gamma-Ray Imager for Design Information Verification of Uranium Enrichment Plants

    International Nuclear Information System (INIS)

    Burks, M.; Verbeke, J.; Dougan, A.; Wang, T.; Decman, D.

    2009-01-01

    A feasibility study has been performed to determine the potential usefulness of Compton imaging as a tool for design information verification (DIV) of uranium enrichment plants. Compton imaging is a method of gamma-ray imaging capable of imaging with a 360-degree field of view over a broad range of energies. These systems can image a room (with a time span on the order of one hour) and return a picture of the distribution and composition of radioactive material in that room. The effectiveness of Compton imaging depends on the sensitivity and resolution of the instrument as well the strength and energy of the radioactive material to be imaged. This study combined measurements and simulations to examine the specific issue of UF 6 gas flow in pipes, at various enrichment levels, as well as hold-up resulting from the accumulation of enriched material in those pipes. It was found that current generation imagers could image pipes carrying UF 6 in less than one hour at moderate to high enrichment. Pipes with low enriched gas would require more time. It was also found that hold-up was more amenable to this technique and could be imaged in gram quantities in a fraction of an hour. another questions arises regarding the ability to separately image two pipes spaced closely together. This depends on the capabilities of the instrument in question. These results are described in detail. In addition, suggestions are given as to how to develop Compton imaging as a tool for DIV

  1. Compton backscattered 511 keV annihilation line emission and the 170 keV line from the Galactic center direction

    Science.gov (United States)

    Lingenfelter, Richard E.; Hua, Xin-Min

    1991-01-01

    It is shown that Compton scattering of 511 keV electron-positron annihilation radiation produces a linelike reflection feature at 170 keV from backscattered photons. Assuming simple models of clouds and accretion disks around a compact source, the paper explores the spectrum of Compton-scattered annihilation line emission for a range of geometries, opacities, and observing angles, and finds that the linelike feature is produced under a wide variety of conditions. It is further shown that such Compton backscattering of slightly redshifted annihilation line emission from the inner edge of an accretion disk could account for the 170 keV line emission and higher energy continuum observed together with the 511 keV annihilation radiation from the direction of the Galactic center. Identification of the observed 170 keV line as a slightly redshifted annihilation line reflection feature provides strong new evidence that the source of this emission is a compact object surrounded by a disk of presumably accreting matter.

  2. Concept and realization of the A4 Compton backscattering polarimeter at MAMI

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Han

    2008-12-15

    The main concern of the A4 parity violation experiment at the Mainzer Microtron accelerator facility is to study the electric and magnetic contributions of strange quarks to the charge and magnetism of the nucleons at the low momentum transfer region. More precisely, the A4 collaboration investigates the strange quarks' contribution to the electric and magnetic vector form factors of the nucleons. Thus, it is important that the A4 experiment uses an adequate and precise non-destructive online monitoring tool for the electron beam polarization when measuring single spin asymmetries in elastic scattering of polarized electrons from unpolarized nucleons. As a consequence, the A4 Compton backscattering polarimeter was designed and installed such that we can take the absolute measurement of the electron beam polarization without interruption to the parity violation experiment. The present study shows the development of an electron beam line that is called the chicane for the A4 Compton backscattering polarimeter. The chicane is an electron beam transport line and provides an interaction region where the electron beam and the laser beam overlap. After studying the properties of beam line components carefully, we developed an electron beam control system that makes a beam overlap between the electron beam and the laser beam. Using the system, we can easily achieve the beam overlap in a short time. The electron control system, of which the performance is outstanding, is being used in production beam times. And the study presents the development of a scintillating fiber electron detector that reduces the statistical error in the electron polarization measurement. We totally redesigned the scintillating fiber detector. The data that were taken during a 2008 beam time shows a huge background suppression, approximately 80 percent, while leaving the Compton spectra almost unchanged when a coincidence between the fiber detector and the photon detector is used. Thus, the

  3. Measurement of Galaxy Cluster Integrated Comptonization and Mass Scaling Relations with the South Pole Telescope

    Energy Technology Data Exchange (ETDEWEB)

    Saliwanchik, B. R.; et al.

    2015-01-22

    We describe a method for measuring the integrated Comptonization (Y (SZ)) of clusters of galaxies from measurements of the Sunyaev-Zel'dovich (SZ) effect in multiple frequency bands and use this method to characterize a sample of galaxy clusters detected in the South Pole Telescope (SPT) data. We use a Markov Chain Monte Carlo method to fit a β-model source profile and integrate Y (SZ) within an angular aperture on the sky. In simulated observations of an SPT-like survey that include cosmic microwave background anisotropy, point sources, and atmospheric and instrumental noise at typical SPT-SZ survey levels, we show that we can accurately recover β-model parameters for inputted clusters. We measure Y (SZ) for simulated semi-analytic clusters and find that Y (SZ) is most accurately determined in an angular aperture comparable to the SPT beam size. We demonstrate the utility of this method to measure Y (SZ) and to constrain mass scaling relations using X-ray mass estimates for a sample of 18 galaxy clusters from the SPT-SZ survey. Measuring Y (SZ) within a 0.'75 radius aperture, we find an intrinsic log-normal scatter of 21% ± 11% in Y (SZ) at a fixed mass. Measuring Y (SZ) within a 0.3 Mpc projected radius (equivalent to 0.'75 at the survey median redshift z = 0.6), we find a scatter of 26% ± 9%. Prior to this study, the SPT observable found to have the lowest scatter with mass was cluster detection significance. We demonstrate, from both simulations and SPT observed clusters that Y (SZ) measured within an aperture comparable to the SPT beam size is equivalent, in terms of scatter with cluster mass, to SPT cluster detection significance.

  4. MEASUREMENT OF GALAXY CLUSTER INTEGRATED COMPTONIZATION AND MASS SCALING RELATIONS WITH THE SOUTH POLE TELESCOPE

    Energy Technology Data Exchange (ETDEWEB)

    Saliwanchik, B. R.; Montroy, T. E. [Physics Department, Center for Education and Research in Cosmology and Astrophysics, Case Western Reserve University, Cleveland, OH 44106 (United States); Aird, K. A. [University of Chicago, 5640 South Ellis Avenue, Chicago, IL 60637 (United States); Bayliss, M. [Department of Physics, Harvard University, 17 Oxford Street, Cambridge, MA 02138 (United States); Benson, B. A.; Bleem, L. E.; Carlstrom, J. E.; Chang, C. L.; Crawford, T. M.; Crites, A. T. [Kavli Institute for Cosmological Physics, University of Chicago, 5640 South Ellis Avenue, Chicago, IL 60637 (United States); Bocquet, S.; Desai, S. [Department of Physics, Ludwig-Maximilians-Universität, Scheinerstr. 1, D-81679 München (Germany); Brodwin, M. [Department of Physics and Astronomy, University of Missouri, 5110 Rockhill Road, Kansas City, MO 64110 (United States); Cho, H. M. [NIST Quantum Devices Group, 325 Broadway, Mailcode 817.03, Boulder, CO 80305 (United States); Clocchiatti, A. [Departamento de Astronomia y Astrofisica, Pontificia Universidad Catolica (Chile); De Haan, T.; Dobbs, M. A.; Dudley, J. P. [Department of Physics, McGill University, 3600 Rue University, Montreal, QC H3A 2T8 (Canada); Foley, R. J.; Forman, W. R., E-mail: benjamin.saliwanchik@case.edu [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); and others

    2015-02-01

    We describe a method for measuring the integrated Comptonization (Y {sub SZ}) of clusters of galaxies from measurements of the Sunyaev-Zel'dovich (SZ) effect in multiple frequency bands and use this method to characterize a sample of galaxy clusters detected in the South Pole Telescope (SPT) data. We use a Markov Chain Monte Carlo method to fit a β-model source profile and integrate Y {sub SZ} within an angular aperture on the sky. In simulated observations of an SPT-like survey that include cosmic microwave background anisotropy, point sources, and atmospheric and instrumental noise at typical SPT-SZ survey levels, we show that we can accurately recover β-model parameters for inputted clusters. We measure Y {sub SZ} for simulated semi-analytic clusters and find that Y {sub SZ} is most accurately determined in an angular aperture comparable to the SPT beam size. We demonstrate the utility of this method to measure Y {sub SZ} and to constrain mass scaling relations using X-ray mass estimates for a sample of 18 galaxy clusters from the SPT-SZ survey. Measuring Y {sub SZ} within a 0.'75 radius aperture, we find an intrinsic log-normal scatter of 21% ± 11% in Y {sub SZ} at a fixed mass. Measuring Y {sub SZ} within a 0.3 Mpc projected radius (equivalent to 0.'75 at the survey median redshift z = 0.6), we find a scatter of 26% ± 9%. Prior to this study, the SPT observable found to have the lowest scatter with mass was cluster detection significance. We demonstrate, from both simulations and SPT observed clusters that Y {sub SZ} measured within an aperture comparable to the SPT beam size is equivalent, in terms of scatter with cluster mass, to SPT cluster detection significance.

  5. Development of a Compton camera for online ion beam range verification via prompt γ detection. Session: HK 12.6 Mo 18:30

    Energy Technology Data Exchange (ETDEWEB)

    Aldawood, S. [LMU Munich, Garching (Germany); King Saud University, Riyadh (Saudi Arabia); Liprandi, S.; Marinsek, T.; Bortfeldt, J.; Lang, C.; Lutter, R.; Dedes, G.; Parodi, K.; Thirolf, P.G. [LMU Munich, Garching (Germany); Maier, L.; Gernhaeuser, R. [TU Munich, Garching (Germany); Kolff, H. van der; Schaart, D. [TU Delft (Netherlands); Castelhano, I. [University of Lisbon, Lisbon (Portugal)

    2015-07-01

    A real-time ion beam verification in hadron-therapy is playing a major role in cancer treatment evaluation. This will make the treatment interuption possible if the planned and actual ion range are mismatched. An imaging system is being developed in Garching aiming to detect prompt γ rays induced by nuclear reactions between the ion beam and biological tissue. The Compton camera prototype consists of a stack of six customized double-sided Si-strip detectors (DSSSD, 50 x 50 mm{sup 2}, 128 strips/side) acting as scatterer, while the absorber is formed by a monolithic LaBr{sub 3}:Ce scintillator crystal (50 x 50 x 30 mm{sup 3}) read out by a position-sensitive multi-anode photomultiplier (Hamamatsu H9500). The study of the Compton camera properties and its individual component are in progress both in the laboratory as well as at the online facilities.

  6. A closed-form formulation for the build-up factor and absorbed energy for photons and electrons in the Compton energy range in Cartesian geometry

    International Nuclear Information System (INIS)

    Borges, Volnei; Vilhena, Marco Tullio; Fernandes, Julio Cesar Lombaldo

    2011-01-01

    In this work, we report on a closed-form formulation for the build-up factor and absorbed energy, in one and two dimensional Cartesian geometry for photons and electrons, in the Compton energy range. For the one-dimensional case we use the LTS N method, assuming the Klein-Nishina scattering kernel for the determination of the angular radiation intensity for photons. We apply the two-dimensional LTS N nodal solution for the averaged angular radiation evaluation for the two-dimensional case, using the Klein-Nishina kernel for photons and the Compton kernel for electrons. From the angular radiation intensity we construct a closed-form solution for the build-up factor and evaluate the absorbed energy. We present numerical simulations and comparisons against results from the literature. (author)

  7. Polarimetric Analysis of the Long Duration Gamma-Ray Burst GRB 160530A With the Balloon Borne Compton Spectrometer and Imager

    Energy Technology Data Exchange (ETDEWEB)

    Lowell, A. W.; Boggs, S. E; Chiu, C. L.; Kierans, C. A.; Sleator, C.; Tomsick, J. A.; Zoglauer, A. C. [Space Sciences Laboratory, University of California, Berkeley (United States); Chang, H.-K.; Tseng, C.-H.; Yang, C.-Y. [Institute of Astronomy, National Tsing Hua University, Taiwan (China); Jean, P.; Ballmoos, P. von [IRAP Toulouse (France); Lin, C.-H. [Institute of Physics, Academia Sinica, Taiwan (China); Amman, M. [Lawrence Berkeley National Laboratory (United States)

    2017-10-20

    A long duration gamma-ray burst, GRB 160530A, was detected by the Compton Spectrometer and Imager (COSI) during the 2016 COSI Super Pressure Balloon campaign. As a Compton telescope, COSI is inherently sensitive to the polarization of gamma-ray sources in the energy range 0.2–5.0 MeV. We measured the polarization of GRB 160530A using (1) a standard method (SM) based on fitting the distribution of azimuthal scattering angles with a modulation curve and (2) an unbinned, maximum likelihood method (MLM). In both cases, the measured polarization level was below the 99% confidence minimum detectable polarization levels of 72.3% ± 0.8% (SM) and 57.5% ± 0.8% (MLM). Therefore, COSI did not detect polarized gamma-ray emission from this burst. Our most constraining 90% confidence upper limit on the polarization level was 46% (MLM).

  8. A closed-form formulation for the build-up factor and absorbed energy for photons and electrons in the Compton energy range in Cartesian geometry

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Volnei; Vilhena, Marco Tullio, E-mail: borges@ufrgs.b, E-mail: vilhena@pq.cnpq.b [Universidade Federal do Rio Grande do Sul (PROMEC/UFRGS), Porto Alegre, RS (Brazil). Programa de Pos-Graduacao em Engenharia Mecanica; Fernandes, Julio Cesar Lombaldo, E-mail: julio.lombaldo@ufrgs.b [Universidade Federal do Rio Grande do Sul (DMPA/UFRGS), Porto Alegre, RS (Brazil). Dept. de Matematica Pura e Aplicada. Programa de Pos Graduacao em Matematica Aplicada

    2011-07-01

    In this work, we report on a closed-form formulation for the build-up factor and absorbed energy, in one and two dimensional Cartesian geometry for photons and electrons, in the Compton energy range. For the one-dimensional case we use the LTS{sub N} method, assuming the Klein-Nishina scattering kernel for the determination of the angular radiation intensity for photons. We apply the two-dimensional LTS{sub N} nodal solution for the averaged angular radiation evaluation for the two-dimensional case, using the Klein-Nishina kernel for photons and the Compton kernel for electrons. From the angular radiation intensity we construct a closed-form solution for the build-up factor and evaluate the absorbed energy. We present numerical simulations and comparisons against results from the literature. (author)

  9. A simple framework for modelling the dependence of bulk Comptonization by turbulence on accretion disc parameters

    Science.gov (United States)

    Kaufman, J.; Blaes, O. M.; Hirose, S.

    2018-03-01

    Warm Comptonization models for the soft X-ray excess in AGN do not self-consistently explain the relationship between the Comptonizing medium and the underlying accretion disc. Because of this, they cannot directly connect the fitted Comptonization temperatures and optical depths to accretion disc parameters. Since bulk velocities exceed thermal velocities in highly radiation pressure dominated discs, in these systems bulk Comptonization by turbulence may provide a physical basis in the disc itself for warm Comptonization models. We model the dependence of bulk Comptonization on fundamental accretion disc parameters, such as mass, luminosity, radius, spin, inner boundary condition, and α. In addition to constraining warm Comptonization models, our model can help distinguish contributions from bulk Comptonization to the soft X-ray excess from those due to other physical mechanisms, such as absorption and reflection. By linking the time variability of bulk Comptonization to fluctuations in the disc vertical structure due to MRI turbulence, our results show that observations of the soft X-ray excess can be used to study disc turbulence in the radiation pressure dominated regime. Because our model connects bulk Comptonization to one dimensional vertical structure temperature profiles in a physically intuitive way, it will be useful for understanding this effect in future simulations run in new regimes.

  10. Simplified slow anti-coincidence circuit for Compton suppression systems

    Energy Technology Data Exchange (ETDEWEB)

    Al-Azmi, Darwish [Department of Applied Sciences, College of Technological Studies, Public Authority for Applied Education and Training, P.O. Box 42325, Shuwaikh 70654 (Kuwait)], E-mail: ds.alazmi@paaet.edu.kw

    2008-08-15

    Slow coincidence circuits for the anti-coincidence measurements have been considered for use in Compton suppression technique. The simplified version of the slow circuit has been found to be fast enough, satisfactory and allows an easy system setup, particularly with the advantage of the automatic threshold setting of the low-level discrimination. A well-type NaI detector as the main detector surrounded by plastic guard detector has been arranged to investigate the performance of the Compton suppression spectrometer using the simplified slow circuit. The system has been tested to observe the improvement in the energy spectra for medium to high-energy gamma-ray photons from terrestrial and environmental samples.

  11. Performance evaluation of MACACO: a multilayer Compton camera

    Science.gov (United States)

    Muñoz, Enrique; Barrio, John; Etxebeste, Ane; Ortega, Pablo G.; Lacasta, Carlos; Oliver, Josep F.; Solaz, Carles; Llosá, Gabriela

    2017-09-01

    Compton imaging devices have been proposed and studied for a wide range of applications. We have developed a Compton camera prototype which can be operated with two or three detector layers based on monolithic lanthanum bromide (LaBr3 ) crystals coupled to silicon photomultipliers (SiPMs), to be used for proton range verification in hadron therapy. In this work, we present the results obtained with our prototype in laboratory tests with radioactive sources and in simulation studies. Images of a 22 Na and an 88 Y radioactive sources have been successfully reconstructed. The full width half maximum of the reconstructed images is below 4 mm for a 22 Na source at a distance of 5 cm.

  12. Simplified slow anti-coincidence circuit for Compton suppression systems

    International Nuclear Information System (INIS)

    Al-Azmi, Darwish

    2008-01-01

    Slow coincidence circuits for the anti-coincidence measurements have been considered for use in Compton suppression technique. The simplified version of the slow circuit has been found to be fast enough, satisfactory and allows an easy system setup, particularly with the advantage of the automatic threshold setting of the low-level discrimination. A well-type NaI detector as the main detector surrounded by plastic guard detector has been arranged to investigate the performance of the Compton suppression spectrometer using the simplified slow circuit. The system has been tested to observe the improvement in the energy spectra for medium to high-energy gamma-ray photons from terrestrial and environmental samples

  13. The Compton-Schwarzschild correspondence from extended de Broglie relations

    Energy Technology Data Exchange (ETDEWEB)

    Lake, Matthew J. [The Institute for Fundamental Study, “The Tah Poe Academia Institute' ,Naresuan University, Phitsanulok 65000 (Thailand); Thailand Center of Excellence in Physics, Ministry of Education,Bangkok 10400 (Thailand); Carr, Bernard [School of Physics and Astronomy, Queen Mary University of London,Mile End Road, London E1 4NS (United Kingdom)

    2015-11-17

    The Compton wavelength gives the minimum radius within which the mass of a particle may be localized due to quantum effects, while the Schwarzschild radius gives the maximum radius within which the mass of a black hole may be localized due to classial gravity. In a mass-radius diagram, the two lines intersect near the Planck point (l{sub P},m{sub P}), where quantum gravity effects become significant. Since canonical (non-gravitational) quantum mechanics is based on the concept of wave-particle duality, encapsulated in the de Broglie relations, these relations should break down near (l{sub P},m{sub P}). It is unclear what physical interpretation can be given to quantum particles with energy E≫m{sub P}c{sup 2}, since they correspond to wavelengths λ≪l{sub P} or time periods τ≪t{sub P} in the standard theory. We therefore propose a correction to the standard de Broglie relations, which gives rise to a modified Schrödinger equation and a modified expression for the Compton wavelength, which may be extended into the region E≫m{sub P}c{sup 2}. For the proposed modification, we recover the expression for the Schwarzschild radius for E≫m{sub P}c{sup 2} and the usual Compton formula for E≪m{sub P}c{sup 2}. The sign of the inequality obtained from the uncertainty principle reverses at m≈m{sub P}, so that the Compton wavelength and event horizon size may be interpreted as minimum and maximum radii, respectively. We interpret the additional terms in the modified de Broglie relations as representing the self-gravitation of the wave packet.

  14. Directional Unfolded Source Term (DUST) for Compton Cameras.

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, Dean J.; Mitchell, Dean J.; Horne, Steven M.; O' Brien, Sean; Thoreson, Gregory G

    2018-03-01

    A Directional Unfolded Source Term (DUST) algorithm was developed to enable improved spectral analysis capabilities using data collected by Compton cameras. Achieving this objective required modification of the detector response function in the Gamma Detector Response and Analysis Software (GADRAS). Experimental data that were collected in support of this work include measurements of calibration sources at a range of separation distances and cylindrical depleted uranium castings.

  15. The Compton-Schwarzschild correspondence from extended de Broglie relations

    International Nuclear Information System (INIS)

    Lake, Matthew J.; Carr, Bernard

    2015-01-01

    The Compton wavelength gives the minimum radius within which the mass of a particle may be localized due to quantum effects, while the Schwarzschild radius gives the maximum radius within which the mass of a black hole may be localized due to classial gravity. In a mass-radius diagram, the two lines intersect near the Planck point (l P ,m P ), where quantum gravity effects become significant. Since canonical (non-gravitational) quantum mechanics is based on the concept of wave-particle duality, encapsulated in the de Broglie relations, these relations should break down near (l P ,m P ). It is unclear what physical interpretation can be given to quantum particles with energy E≫m P c 2 , since they correspond to wavelengths λ≪l P or time periods τ≪t P in the standard theory. We therefore propose a correction to the standard de Broglie relations, which gives rise to a modified Schrödinger equation and a modified expression for the Compton wavelength, which may be extended into the region E≫m P c 2 . For the proposed modification, we recover the expression for the Schwarzschild radius for E≫m P c 2 and the usual Compton formula for E≪m P c 2 . The sign of the inequality obtained from the uncertainty principle reverses at m≈m P , so that the Compton wavelength and event horizon size may be interpreted as minimum and maximum radii, respectively. We interpret the additional terms in the modified de Broglie relations as representing the self-gravitation of the wave packet.

  16. Quantitative Compton suppression spectrometry at elevated counting rates

    International Nuclear Information System (INIS)

    Westphal, G.P.; Joestl, K.; Schroeder, P.; Lauster, R.; Hausch, E.

    1999-01-01

    For quantitative Compton suppression spectrometry the decrease of coincidence efficiency with counting rate should be made negligible to avoid a virtual increase of relative peak areas of coincident isomeric transitions with counting rate. To that aim, a separate amplifier and discriminator has been used for each of the eight segments of the active shield of a new well-type Compton suppression spectrometer, together with an optimized, minimum dead-time design of the anticoincidence logic circuitry. Chance coincidence losses in the Compton suppression spectrometer are corrected instrumentally by comparing the chance coincidence rate to the counting rate of the germanium detector in a pulse-counting Busy circuit (G.P. Westphal, J. Rad. Chem. 179 (1994) 55) which is combined with the spectrometer's LFC counting loss correction system. The normally not observable chance coincidence rate is reconstructed from the rates of germanium detector and scintillation detector in an auxiliary coincidence unit, after the destruction of true coincidence by delaying one of the coincidence partners. Quantitative system response has been tested in two-source measurements with a fixed reference source of 60 Co of 14 kc/s, and various samples of 137 Cs, up to aggregate counting rates of 180 kc/s for the well-type detector, and more than 1400 kc/s for the BGO shield. In these measurements, the net peak areas of the 1173.3 keV line of 60 Co remained constant at typical values of 37 000 with and 95 000 without Compton suppression, with maximum deviations from the average of less than 1.5%

  17. Basic lecture on imaging processing II. Scatter correction

    International Nuclear Information System (INIS)

    Motomura, Nobutoku

    2001-01-01

    Basic knowledge of scattered radiation, method of scatter correction and the triple energy window (TEW) method are reviewed. Introduction contains Compton scattering of γ-ray and scattered radiations of single and multiple energy γ-rays which affect on images. Methods of correction involve those of convolution subtraction, scatter line spread function, transmission dependent convolution subtraction, dual energy window subtraction, dual photopeak window and TEW. The TEW estimates scattering radiations from sub-windows set at both sides of the major photoelectric peak window and its setting procedure is described. Evaluation of the TEW method is also described on 3 phantoms of different shapes and on clinical 123 I-IMP SPECT data of the head. Use of Butterworth filter is recommended to reduce the statistic noise in the sub-windows. (K.H.)

  18. Electronic structure of AlAs: A Compton profile study

    International Nuclear Information System (INIS)

    Sharma, G.; Joshi, K.B.; Mishra, M.C.; Kothari, R.K.; Sharma, Y.C.; Vyas, V.; Sharma, B.K.

    2009-01-01

    The electronic structure of AlAs through a Compton profile study is presented in this paper. Theoretical calculations are performed following the linear combination of atomic orbitals (LCAO) method and the empirical pseudopotential method (EPM). In LCAO method, to treat exchange and correlation two cases are considered. In the first case, the exchange function of Becke and the correlation function of Perdew and Wang on the basis of generalized gradient approximation (PW-GGA) is adopted. In the second case, the hybrid function B3PW is adopted. Measurement of Compton profile on the polycrystalline AlAs is performed using 59.54 keV gamma-rays. The spherically averaged theoretical Compton profiles are in good agreement with the measurement. The best agreement is, however, shown by the EPM. The anisotropies predicted by B3PW and the EPM are smaller than those from the PW-GGA calculation. On the basis of equal-valence-electron-density profiles, it is found that AlAs is more covalent compared to AlN. The charge transfer model suggests transfer of 0.6e - from Al to As on compound formation.

  19. Compton profile study and electronic properties of tantalum diboride

    International Nuclear Information System (INIS)

    Raykar, Veera; Bhamu, K.C.; Ahuja, B.L.

    2013-01-01

    We have reported the first-ever experimental Compton profile (CP) of TaB 2 using 20 Ci 137 Cs Compton spectrometer. To compare the experimental data, we have also computed the theoretical CPs using density functional theory (DFT) and hybridization of DFT and Hartree–Fock (HF) within linear combination of the atomic orbitals (LCAO) method. In addition, we have reported energy bands and density of states of TaB 2 using LCAO and full potential-linearized augmented plane wave (FP-LAPW) methods. A real space analysis of CP of TaB 2 confirms its metallic character which is in tune with the cross-overs of Fermi level by energy bands and Fermi surface topology. A comparison of equal-valence-electron-density (EVED) experimental profiles of isoelectronic TaB 2 and NbB 2 show more covalent (or less ionic) character of TaB 2 than that of NbB 2 which is in agreement with available ionicity data. - Highlights: ► Reported first-ever experimental Compton profile (CP) of TaB 2 . ► Interpreted experimental CP using theoretical CP within density functional theory. ► Analyzed equal-valence-electron-density experimental CPs of TaB 2 and NbB 2 . ► Established metallic character by taking Fourier transform of experimental CP. ► Reported energy bands, DOS and Fermi surface of TaB 2 using LCAO and FP-LAPW

  20. Compton-thick AGNs in the NuSTAR Era

    Science.gov (United States)

    Marchesi, S.; Ajello, M.; Marcotulli, L.; Comastri, A.; Lanzuisi, G.; Vignali, C.

    2018-02-01

    We present the 2–100 keV spectral analysis of 30 candidate Compton-thick-(CT-)active galactic nuclei (AGNs) selected in the Swift-Burst Alert Telescope (BAT) 100 month survey. The average redshift of these objects is ∼ 0.03, and they all lie within ∼500 Mpc. We used the MyTorus model to perform X-ray spectral fittings both without and with the contribution of the Nuclear Spectroscopic Telescope Array (NuSTAR) data in the 3–50 keV energy range. When the NuSTAR data are added to the fit, 13 out of 30 of these objects (43% of the whole sample) have intrinsic absorption N H 3σ confidence level, i.e., they are reclassified from Compton thick to Compton thin. Consequently, we infer an overall observed fraction of the CT-AGN, with respect to the whole AGN population, lower than the one reported in previous works, as low as ∼4%. We find evidence that this overestimation of N H is likely due to the low quality of a subsample of spectra, either in the 2–10 keV band or in the Swift-BAT one.