WorldWideScience

Sample records for underground ventilation system

  1. Underground ventilation remote monitoring and control system

    International Nuclear Information System (INIS)

    Strever, M.T.; Wallace, K.G. Jr.; McDaniel, K.H.

    1995-01-01

    This paper presents the design and installation of an underground ventilation remote monitoring and control system at the Waste Isolation Pilot Plant. This facility is designed to demonstrate safe underground disposal of U.S. defense generated transuranic nuclear waste. To improve the operability of the ventilation system, an underground remote monitoring and control system was designed and installed. The system consists of 15 air velocity sensors and 8 differential pressure sensors strategically located throughout the underground facility providing real-time data regarding the status of the ventilation system. In addition, a control system was installed on the main underground air regulators. The regulator control system gives indication of the regulator position and can be controlled either locally or remotely. The sensor output is displayed locally and at a central surface location through the site-wide Central Monitoring System (CMS). The CMS operator can review all sensor data and can remotely operate the main underground regulators. Furthermore, the Virtual Address Extension (VAX) network allows the ventilation engineer to retrieve real-time ventilation data on his personal computer located in his workstation. This paper describes the types of sensors selected, the installation of the instrumentation, and the initial operation of the remote monitoring system

  2. Computer modelling of an underground mine ventilation system

    International Nuclear Information System (INIS)

    1984-12-01

    The ability to control workplace short-lived radon daughter concentrations to appropriate levels is crucial to the underground mining of uranium ores. Recognizing that mine ventilation models can be used to design ventilation facilities in new mines and to evaluate proposed ventilation changes in existing mines the Atomic Energy Control Board (AECB) initiated this study to first investigate existing mine ventilation models and then develop a suitable model for use by AECB staff. At the start of the study, available literature on mine ventilation models, in partiuclar models suitable for the unique task of predicting radon daughter levels, were reviewed. While the details of the models varied, it was found that the basic calculation procedures used by the various models were similar. Consequently, a model developed at Queen's University that not only already incorporated most of the desired features but was also readily available, was selected for implementation. Subsequently, the Queen's computer program (actually two programs, one for mine ventilation and one to calculate radon daughter levels) was extended and tested. The following report provides the relevant documentation for setting up and running the models. The mathematical basis of the calculational procedures used in the models are also described

  3. Initial computer modeling of WIPP [Waste Isolation Pilot Plant] underground ventilation system, September 1985--March 1986

    International Nuclear Information System (INIS)

    Sethi, S.

    1986-11-01

    Provision of a good ventilation system has been and continues to be a major priority here of those responsible for its design, management, and operation. As an ongoing effort in this direction, development of computer simulated models for the system was initiated in September, 1985. It was decided to utilize Dravo's 'MINEVENT' computer program for this purpose. Accordingly, initial computer models of the mine's ventilation system have been developed for various modes of operation. Specifically, they include: Simulation of the current ventilation system, and Simulation of the designed ventilation system for modes: mine construction mode/shift, waste storage mode/shift, and air reversal mode. 5 figs

  4. Effect of repository underground ventilation on emplacement drift temperature control

    International Nuclear Information System (INIS)

    Yang, H.; Sun, Y.; McKenzie, D.G.; Bhattacharyya, K.K.

    1996-01-01

    The repository advanced conceptual design (ACD) is being conducted by the Civilian Radioactive Waste Management System, Management ampersand Operating Contractor. Underground ventilation analyses during ACD have resulted in preliminary ventilation concepts and design methodologies. This paper discusses one of the recent evaluations -- effects of ventilation on emplacement drift temperature management

  5. Ventilation systems

    International Nuclear Information System (INIS)

    Gossler

    1980-01-01

    The present paper deals with - controlled area ventilation systems - ventilation systems for switchgear-building and control-room - other ventilation systems for safety equipments - service systems for ventilation systems. (orig./RW)

  6. Subsurface Ventilation System Description Document

    Energy Technology Data Exchange (ETDEWEB)

    Eric Loros

    2001-07-25

    The Subsurface Ventilation System supports the construction and operation of the subsurface repository by providing air for personnel and equipment and temperature control for the underground areas. Although the system is located underground, some equipment and features may be housed or located above ground. The system ventilates the underground by providing ambient air from the surface throughout the subsurface development and emplacement areas. The system provides fresh air for a safe work environment and supports potential retrieval operations by ventilating and cooling emplacement drifts. The system maintains compliance within the limits established for approved air quality standards. The system maintains separate ventilation between the development and waste emplacement areas. The system shall remove a portion of the heat generated by the waste packages during preclosure to support thermal goals. The system provides temperature control by reducing drift temperature to support potential retrieval operations. The ventilation system has the capability to ventilate selected drifts during emplacement and retrieval operations. The Subsurface Facility System is the main interface with the Subsurface Ventilation System. The location of the ducting, seals, filters, fans, emplacement doors, regulators, and electronic controls are within the envelope created by the Ground Control System in the Subsurface Facility System. The Subsurface Ventilation System also interfaces with the Subsurface Electrical System for power, the Monitored Geologic Repository Operations Monitoring and Control System to ensure proper and safe operation, the Safeguards and Security System for access to the emplacement drifts, the Subsurface Fire Protection System for fire safety, the Emplacement Drift System for repository performance, and the Backfill Emplacement and Subsurface Excavation Systems to support ventilation needs.

  7. Subsurface Ventilation System Description Document

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-10-12

    The Subsurface Ventilation System supports the construction and operation of the subsurface repository by providing air for personnel and equipment and temperature control for the underground areas. Although the system is located underground, some equipment and features may be housed or located above ground. The system ventilates the underground by providing ambient air from the surface throughout the subsurface development and emplacement areas. The system provides fresh air for a safe work environment and supports potential retrieval operations by ventilating and cooling emplacement drifts. The system maintains compliance within the limits established for approved air quality standards. The system maintains separate ventilation between the development and waste emplacement areas. The system shall remove a portion of the heat generated by the waste packages during preclosure to support thermal goals. The system provides temperature control by reducing drift temperature to support potential retrieval operations. The ventilation system has the capability to ventilate selected drifts during emplacement and retrieval operations. The Subsurface Facility System is the main interface with the Subsurface Ventilation System. The location of the ducting, seals, filters, fans, emplacement doors, regulators, and electronic controls are within the envelope created by the Ground Control System in the Subsurface Facility System. The Subsurface Ventilation System also interfaces with the Subsurface Electrical System for power, the Monitored Geologic Repository Operations Monitoring and Control System to ensure proper and safe operation, the Safeguards and Security System for access to the emplacement drifts, the Subsurface Fire Protection System for fire safety, the Emplacement Drift System for repository performance, and the Backfill Emplacement and Subsurface Excavation Systems to support ventilation needs.

  8. Improving underground ventilation conditions in coal mines

    CSIR Research Space (South Africa)

    Meyer, CF

    1993-11-01

    Full Text Available The aim of this project was to establish the needs of the industry with regard to bord and pillar ventilation requirements. In addition, the aim was to establish whether sufficient research has already been done by the mining industry and if further...

  9. VENTILATION TECHNOLOGY SYSTEMS ANALYSIS

    Science.gov (United States)

    The report gives results of a project to develop a systems analysis of ventilation technology and provide a state-of-the-art assessment of ventilation and indoor air quality (IAQ) research needs. (NOTE: Ventilation technology is defined as the hardware necessary to bring outdoor ...

  10. Discussion for management of ventilation system in uranium mines

    International Nuclear Information System (INIS)

    Li Xianjie; Ren Jianjun; Hu Penghua

    2014-01-01

    Radon exhaustion and ventilation are surely regarded as key links for safety production and radiation protection in underground uranium mines, and the crucial point to achieve safety production goals lies in timely and accurately adjusting and controlling of ventilation technical measures and ventilation system management with the changing operation conditions of mines. This paper proposes corresponding countermeasures based on the respectively systematical analysis of daily ventilation management, ventilation facilities and structures management, and ventilation system information management in uranium mines. Furthermore, standardized management approaches and suggestions are put forward to realize standardization of uranium mines' ventilation management and radon exhaustion technique. (authors)

  11. Ventilation experiment in the Mont Terri underground laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Mayor, J.C. [Empresa Nacional de Residuos Radiactivos, SA (ENRESA), Madrid (Spain); Velasco, M. [Dm-Iberia, Consultores en ciencias de la tierra, Madrid (Spain); Garcia-Sineriz, J.L. [Aitemin, Madrid (Spain)

    2005-07-01

    The required ventilation of the underground drifts during the construction and operational phases of a radioactive waste repository could give rise to a process of desaturation of the rock around the drifts, changing its hydraulic and thermal properties. This change of rock properties may have an impact on the design of the repositories (drifts spacing and repository size), which depends on the thermal load that the clay barrier and the rock can accept. The Ventilation Experiment (VE) has been carried out at the Mont Terri underground laboratory (Switzerland), and has been co-financed by the EC under contract FIKW-CT-2001-00126. Its main objective was to evaluate in-situ and better understand the desaturation process of a consolidated clay formation, when subjected to a flow of dry air during several months. This VE test has been performed under practically isothermal conditions (T {approx_equal} 15-16 C), in a 10 m long section of a non-lined horizontal micro-tunnel (diameter = 1,3 m), excavated in 1999 in the shaly facies of the Opalinus clay of Mont Terri. In the summer of year 2002 (3,4 years after the micro-tunnel excavation), the test section was sealed off by means of two double doors, and monitored with a total of 96 sensors (rock water potential, water content, temperature and displacements, and conditions of the air in the test section). Specifically, in a rock thickness of approximately two meters, 24 piezometers, 32 hygrometers, 10 TDR, 8 extensometers and 5 electrodes chains (geo-electrical survey) were installed. Hydraulic, geochemical and geo-electrical laboratory tests have been also performed to characterize the Opalinus clay properties. Besides, the in-situ VE test has been interpreted and modelled, using the obtained experimental data for calibration of several codes, such as the Code-Bright, Code-Aster, Tough 2 and Mherlin. (authors)

  12. Protective garment ventilation system

    Science.gov (United States)

    Lang, R. (Inventor)

    1970-01-01

    A method and apparatus for ventilating a protective garment, space suit system, and/or pressure suits to maintain a comfortable and nontoxic atmosphere within is described. The direction of flow of a ventilating and purging gas in portions of the garment may be reversed in order to compensate for changes in environment and activity of the wearer. The entire flow of the ventilating gas can also be directed first to the helmet associated with the garment.

  13. An embedded underground navigation system

    CSIR Research Space (South Africa)

    Hlophe, K

    2011-11-01

    Full Text Available Platform pose (localization and orientation) information is a key requirement for autonomous mobile systems. The severe natural conditions and complex terrain of underground mines diminish the capability of most pose estimation systems, especially...

  14. Proximity detection system underground

    Energy Technology Data Exchange (ETDEWEB)

    Denis Kent [Mine Site Technologies (Australia)

    2008-04-15

    Mine Site Technologies (MST) with the support ACARP and Xstrata Coal NSW, as well as assistance from Centennial Coal, has developed a Proximity Detection System to proof of concept stage as per plan. The basic aim of the project was to develop a system to reduce the risk of the people coming into contact with vehicles in an uncontrolled manner (i.e. being 'run over'). The potential to extend the developed technology into other areas, such as controls for vehicle-vehicle collisions and restricting access of vehicle or people into certain zones (e.g. non FLP vehicles into Hazardous Zones/ERZ) was also assessed. The project leveraged off MST's existing Intellectual Property and experience gained with our ImPact TRACKER tagging technology, allowing the development to be fast tracked. The basic concept developed uses active RFID Tags worn by miners underground to be detected by vehicle mounted Readers. These Readers in turn provide outputs that can be used to alert a driver (e.g. by light and/or audible alarm) that a person (Tag) approaching within their vicinity. The prototype/test kit developed proved the concept and technology, the four main components being: Active RFID Tags to send out signals for detection by vehicle mounted receivers; Receiver electronics to detect RFID Tags approaching within the vicinity of the unit to create a long range detection system (60 m to 120 m); A transmitting/exciter device to enable inner detection zone (within 5 m to 20 m); and A software/hardware device to process & log incoming Tags reads and create certain outputs. Tests undertaken in the laboratory and at a number of mine sites, confirmed the technology path taken could form the basis of a reliable Proximity Detection/Alert System.

  15. Analysis on ventilation pressure of fire area in longitudinal ventilation of underground tunnel

    Science.gov (United States)

    Li, Jiaxin; Li, Yanfeng; Feng, Xiao; Li, Junmei

    2018-03-01

    In order to solve the problem of ventilation pressure loss in the fire area under the fire condition, the wind pressure loss model of the fire area is established based on the thermodynamic equilibrium relation. The semi-empirical calculation formula is obtained by using the model experiment and CFD simulation. The validity of the formula is verified. The results show that the ventilation pressure loss in the fire zone is proportional to the convective heat release rate at the critical velocity, which is inversely proportional to the upstream ventilation velocity and the tunnel cross-sectional area. The proposed formula is consistent with the law of the tunnel fire test fitting formula that results are close, in contrast, the advantage lies in a clear theoretical basis and ventilation velocity values. The resistance of road tunnel ventilation system is calculated accurately and reliably, and then an effective emergency ventilation operation program is developed. It is necessary to consider the fire zone ventilation pressure loss. The proposed ventilation pressure loss formula can be used for design calculation after thorough verification.

  16. A study of reducing radon level by ventilation in underground space

    International Nuclear Information System (INIS)

    Li Xiaoyan; Wang Yan; Chinese Academy of Sciences, Beijing; Zheng Baoshan; Wang Xue

    2005-01-01

    Using Model 1027 continuous radon monitor, a test of reducing radon level by ventilation in underground space was done. Four different types of ventilation, i.e. by air pump (P), by air intake blower (B), by air pump and air intake blower simultaneously (PBS), and by air pump and air intake blower in turn (PBT), were examined. The authors found that efficiency of PBS is the highest among these ventilation type. Having ventilated the underground space with PBS for 1, 2 or 3 hours in three different days, and having observed the radon concentration change in the following 24 hours, the authors can conclude that it is safe for people to stay there during the eight working hours if the underground space is ventilated for 2 hours everyday in the morning. (authors)

  17. Estimation of radon daughter levels in the ventilation planning of an underground uranium mine

    International Nuclear Information System (INIS)

    Gan, T.H.; Wise, K.N.; Leach, V.A.

    1981-01-01

    Diffusion parameters determined by laboratory measurements can be utilized for predictions of radon daughter exposures in underground mining environments, as well as providing data for ventilation planning purposes. Wherever possible field measured data for the various diffusion parameters should be used. Underground mining methods, the tunnel model and diffusion theory are considered

  18. Overall Subsurface Ventilation Systems

    International Nuclear Information System (INIS)

    Thomas, Edward G.

    2000-01-01

    The purpose of this analysis is to provide a conceptual design for the Subsurface Ventilation System and address the construction, emplacement, monitoring, backfill, and closure ventilation phases. The design will be based on the recently established program requirements for transitioning to the Site Recommendation (SR) design as outlined by ''Approach to Implementing the Site Recommendation Baseline'' (Stroupe 2000) and the Monitored Geologic Repository Project Description Document (CRWMS M and O 1999d) (MGR). This analysis will summarize the ventilation concepts that have developed from the incorporation of recent changes to the Technical Baseline and describe changes to the conceptual ventilation design that have resulted from the thermal management requirements. Ventilation concepts presented in the Viability Assessment Design (VA Design) that have not changed are identified and included. The objective of this analysis is to provide a basis for the System Description Document (SDD) Section 2 that provides input to the SR Consideration Report. The scope of the analysis includes the following tasks: (1) Determine the number of primary shafts based on the emplacement airflow rate required to meet thermal goals and (2) Determine conceptual airflow networks for major repository phases including: Construction; Emplacement; Monitoring; and Closure. In addition evaluate: (1) Radon mitigation concerns and options; (2) Monitoring and control requirement changes needed to meet current guidelines; and (3) The impact on the ventilation system of a radiological release due to a potential subsurface fire involving a waste package

  19. Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Toke Rammer; Svendsen, Sv Aa Højgaard

    1999-01-01

    The note concerns ventilation in residential buildings. Describes components in ventilation systems, electric energy consumption and different ventilation systems with heat exchanger.......The note concerns ventilation in residential buildings. Describes components in ventilation systems, electric energy consumption and different ventilation systems with heat exchanger....

  20. A GIS-based approach: Influence of the ventilation layout to the environmental conditions in an underground mine.

    Science.gov (United States)

    Bascompta, Marc; Castañón, Ana María; Sanmiquel, Lluís; Oliva, Josep

    2016-11-01

    Gases such as CO, CO2 or NOx are constantly generated by the equipment in any underground mine and the ventilation layout can play an important role in keeping low concentrations in the working faces. Hence, a method able to control the workplace environment is crucial. This paper proposes a geographical information system (GIS) for such goal. The system created provides the necessary tools to manage and analyse an underground environment, connecting pollutants and temperatures with the ventilation characteristics over time. Data concerning the ventilation system, in a case study, has been taken every month since 2009 and integrated into the management system, which has quantified the gasses concentration throughout the mine due to the characteristics and evolution of the ventilation layout. Three different zones concerning CO, CO2, NOx and effective temperature have been found as well as some variations among workplaces within the same zone that suggest local airflow recirculations. The system proposed could be a useful tool to improve the workplace conditions and efficiency levels. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. How to Plan Ventilation Systems.

    Science.gov (United States)

    Clarke, John H.

    1963-01-01

    Ventilation systems for factory safety demand careful planning. The increased heat loads and new processes of industry have introduced complex ventilation problems in--(1) ventilation supply, (2) duct work design, (3) space requirements, (4) hood face velocities, (5) discharge stacks, and (6) building eddies. This article describes and diagrams…

  2. 30 CFR 75.324 - Intentional changes in the ventilation system.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Intentional changes in the ventilation system... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.324 Intentional changes in the ventilation system. (a) A person designated by the operator shall supervise any...

  3. Emplacement ventilation system

    International Nuclear Information System (INIS)

    Vance, Robert W.

    2000-01-01

    This analysis updates design concepts for emplacement ventilation based upon the increased air flow required through the drift in the EDA II design (CRWMS M and O 1999a, Table O-6) and by current thermal modeling results compared to the VA design (DOE 1998, Section 4.2.4). It reviews the air pathway in the emplacement drift, describes three exhaust system options, discusses two air control options, and examines concepts for several system physical components including isolation doors, a portable shadow shield, and a partition in an exhaust main. The air path through the emplacement drift, itself, remains the same as described in the VA and EDA II design; that is, exhaust fans located on the surface pull air through an intake shaft into the subsurface repository. The ventilation air is distributed to the east and west mains by the cross-block drifts. From the mains, the air enters the emplacement drifts and flows to a central exhaust raise. The air then travels down an exhaust raise to the exhaust system

  4. Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems

    OpenAIRE

    Sherman, Max H.

    2011-01-01

    Existing ventilation standards, including American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE) Standard 62.2, specify continuous operation of a defined mechanical ventilation system to provide minimum ventilation, with time-based intermittent operation as an option. This requirement ignores several factors and concerns including: other equipment such as household exhaust fans that might incidentally provide ventilation, negative impacts of ventilation when outd...

  5. Control of ventilation system when changing of its topology

    International Nuclear Information System (INIS)

    Koketayev, A.I.

    2009-01-01

    The complex ventilation systems of modern coal and ore mines can be described by multidimensional and highly bound graphs. Because of changes in topology, it is very difficult to control ventilation systems in the event of emergency situations such as rock bumps, roof caving, sudden gas outburst, quicksand intrusion, or mine flooding. Special mathematical tools are needed to consider such changes and to determine the corresponding conditions of a mine's ventilation needs. This paper presented a system to simulate the behaviour of mine ventilation system. The system considered changes in topology as well as timely measures for support of necessary air quantity for safe conditions for miners in underground mine workings. The paper presented the details of the study with particular reference to the calculation of ventilation conditions; graphs and sub-graphs of the ventilation system; and corresponding equations. It was concluded that the simulated system would allow users to simulate the behaviour of the mine ventilation system when changing its topology in a timely manner and to take measures to control the required volume of air to ensure safe working conditions for underground miners. 3 refs., 1 fig.

  6. Demand Controlled Ventilation in a Combined Ventilation and Radiator System

    OpenAIRE

    Hesaraki, Arefeh; Holmberg, Sture

    2013-01-01

    With growing concerns for efficient and sustainable energy treatment in buildings there is a need for balanced and intelligent ventilation solutions. This paper presents a strategy for demand controlled ventilation with ventilation radiators, a combined heating and ventilation system. The ventilation rate was decreased from normal requirements (per floor area) of 0.375 l·s-1·m-2 to 0.100 l·s-1·m-2 when the residence building was un-occupied. The energy saving potential due to decreased ventil...

  7. Modelling an in-situ ventilation test in the Andra Underground Research Facilities

    Directory of Open Access Journals (Sweden)

    Collin Frédéric

    2016-01-01

    Full Text Available Wastes resulting from the nuclear electricity production have to be isolated from the biosphere for a very long period of time. For this purpose, deep underground repository in weak permeable geological layers is considered as a reliable solution for the nuclear waste storage. It is however well established that during excavation, the underground drilling process engenders cracks and eventually fractures [1] that deteriorate the hydro-mechanical properties of the surrounding host material in the so-called Excavation Damaged Zone (EDZ. The EDZ behaviour is a major issue because it may constitute a preferential flow path for radionuclide migration. Consequently, the characterisation of the material transport properties and of the transfer kinetics that occur around galleries still need to be investigated. The EDZ properties may be also affected by host rock-gallery air interactions. Ventilation induced drying may also provoke additional cracking, which potentially alters the transport properties of the damaged zone. Large-scale air ventilation experiments are performed in Underground Research Laboratories (URL that have been constructed to check the feasibility of the repository. A numerical modelling of the SDZ air ventilation test (Andra URL performed in a low permeability rock is proposed in order to both predict the development of the EDZ during excavation and study the air interaction with the host formation during maintenance phases.

  8. Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.; Walker, Iain S.

    2011-04-01

    Existing ventilation standards, including American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE) Standard 62.2, specify continuous operation of a defined mechanical ventilation system to provide minimum ventilation, with time-based intermittent operation as an option. This requirement ignores several factors and concerns including: other equipment such as household exhaust fans that might incidentally provide ventilation, negative impacts of ventilation when outdoor pollutant levels are high, the importance of minimizing energy use particularly during times of peak electricity demand, and how the energy used to condition air as part of ventilation system operation changes with outdoor conditions. Dynamic control of ventilation systems can provide ventilation equivalent to or better than what is required by standards while minimizing energy costs and can also add value by shifting load during peak times and reducing intake of outdoor air contaminants. This article describes the logic that enables dynamic control of whole-house ventilation systems to meet the intent of ventilation standards and demonstrates the dynamic ventilation system control concept through simulations and field tests of the Residential Integrated Ventilation-Energy Controller (RIVEC).

  9. FEATURES OF VENTILATION CONDITIONS BY MUSHROOM CULTIVATION IN MINING UNDERGROUND WORKINGS

    Directory of Open Access Journals (Sweden)

    Vladimir Rendulić

    1991-12-01

    Full Text Available The trial cultivation of mushrooms (Agaricus bisporus in one of the dead faces of the »Krš« pit of the Dalmatian bauxite mines Obrovac proved, that an optimal yield can be attained with the domestic mycelium. The decision has been brought to go on with investments into equipment for new growing-site locations in underground workings of the mine. In order to cultivate high-quality mushrooms, the ventilation of growing sites has been particularly considered. Compressive separate ventilation of growing fields has been applied using the main and the return ventilating pipeline, with the air current regulation according to the growing stage (the paper is published in Croatian.

  10. Preoperational test report, vent building ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-04

    This represents a preoperational test report for Vent Building Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides Heating, Ventilation, and Air Conditioning (HVAC) for the W-030 Ventilation Building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  11. 46 CFR 111.103-1 - Power ventilation systems except machinery space ventilation systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Power ventilation systems except machinery space ventilation systems. 111.103-1 Section 111.103-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... Power ventilation systems except machinery space ventilation systems. Each power ventilation system must...

  12. Water spray ventilator system for continuous mining machines

    Science.gov (United States)

    Page, Steven J.; Mal, Thomas

    1995-01-01

    The invention relates to a water spray ventilator system mounted on a continuous mining machine to streamline airflow and provide effective face ventilation of both respirable dust and methane in underground coal mines. This system has two side spray nozzles mounted one on each side of the mining machine and six spray nozzles disposed on a manifold mounted to the underside of the machine boom. The six spray nozzles are angularly and laterally oriented on the manifold so as to provide non-overlapping spray patterns along the length of the cutter drum.

  13. 14 CFR 252.9 - Ventilation systems.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Ventilation systems. 252.9 Section 252.9... REGULATIONS SMOKING ABOARD AIRCRAFT § 252.9 Ventilation systems. Air carriers shall prohibit smoking whenever the ventilation system is not fully functioning. Fully functioning for this purpose means operating so...

  14. Improvements of uranium mine ventilation system

    International Nuclear Information System (INIS)

    Liu Changrong; Zhou Xinghuo; Liu Zehua; Wang Zhiyong

    2007-01-01

    Ventilation has been proved to be a main method to eliminate radon and its daughters in uranium mines. According to the practical rectifications of uranium mine ventilation system, the improved measures are summarized. (authors)

  15. YMP Engineered Barrier Systems Scaled Ventilation Testing

    Energy Technology Data Exchange (ETDEWEB)

    S.D. Dunn; B. Lowry; B. Walsh; J.D. Mar; C. Howard; R. Johnston; T. Williams

    2002-11-22

    Yucca Mountain, approximately 100 miles northwest of Las Vegas, Nevada, has been selected as the site for the nation's first geologic repository for high level nuclear waste. The Yucca Mountain Project (YMP) is currently developing the design for the underground facilities. Ventilation is a key component of the design as a way to maintain the desired thermal conditions in the emplacement drifts prior to closure. As a means of determining the effects of continuous ventilation on heat removal from the emplacement drifts two series of scaled ventilation tests have been performed. Both test series were performed in the DOE/North Las Vegas Atlas facility. The tests provided scaled (nominally 25% of the full scale emplacement drift design) thermal and flow process data that will be used to validate YMP heat and mass transport codes. The Phase I Ventilation Test series evaluated the ability of ambient ventilation air to remove energy under varying flow and input power conditions. The Phase II Ventilation Test series evaluated the ability of pre-conditioned ventilation air to remove energy under varying flow, input temperature and moisture content, and simulated waste package input power conditions. Twenty-two distinct ventilation tests were run.

  16. Ventilation system in the RA reactor building - design specifications

    International Nuclear Information System (INIS)

    Badrljica, R.

    1984-09-01

    Protective role of the ventilation system of nuclear facilities involve construction of ventilation barriers which prevent release of radioactive particulates or gases, elimination od radioactive particulates and gases from the air which is released from contaminated zones into the reactor environment. Ventilation barriers are created by dividing the building into a number of ventilation zones with different sub pressure compared to the atmospheric pressure. The RA reactor building is divided into four ventilation zones. First zone is the zone of highest risk. It includes reactor core with horizontal experimental channels, underground rooms of the primary coolant system (D 2 O), helium system, hot cells and the space above the the reactor core. Second zone is the reactor hall and the room for irradiated fuel storage. The third zone includes corridors in the basement, ground floor and first floor where the probability of contamination is small. The fourth zone includes the annex where the contamination risk is low. There is no have natural air circulation in the reactor building. Ventilators for air input and outlet maintain the sub pressure in the building (pressure lower than the atmospheric pressure). This prevents release of radioactivity into the atmosphere [sr

  17. 40 CFR 280.230 - Operating an underground storage tank or underground storage tank system.

    Science.gov (United States)

    2010-07-01

    ... underground storage tank or underground storage tank system. (a) Operating an UST or UST system prior to...) Operating an UST or UST system after foreclosure. The following provisions apply to a holder who, through..., the purchaser must decide whether to operate or close the UST or UST system in accordance with...

  18. 30 CFR 57.4360 - Underground alarm systems.

    Science.gov (United States)

    2010-07-01

    ... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground alarm systems. 57.4360 Section 57...

  19. The effect of time-dependent ventilation and radon (thoron) gas emanation rates in underground uranium mines

    International Nuclear Information System (INIS)

    Bigu, J.

    1987-01-01

    A theoretical radiation mine model, suitable for underground uranium mines, has been investigated. In this model, the rate of ventilation and/or the radon (thoron) gas emanation from mine walls are time-dependent. Several cases of practical interest have been investigated including sinusoidal, linear, exponential, stepwise, or a combination of two or more of the above. Analytical solutions were obtained for the time-dependent radon (thoron) gas emanation rate. However, because of the extreme analytical complexity of the solutions corresponding to the time-dependent ventilation rate case, numerical solutions were found using a special Runge-Kutta procedure and the Hamming's modified predictor-corrector method for the solution of linear initial-value problems. The mine model makes provisions for losses of radioactivity, other than by ventilation and radioactive decay, by, say, plate-out on mine walls, and by other mechanisms. Radioactivity data, i.e., radon, thoron, and their progeny, obtained with the above mine model for a number of ventilation and emanation conditions, are presented. Experimental data obtained in an inactive stope of an underground uranium mine for a time-dependent air flow case are shown. Air flow conditions (ventilation rate) were determined by tracer gas techniques using SF 6

  20. Decommissioning of underground structures, systems and components

    International Nuclear Information System (INIS)

    2006-01-01

    A large number of operational and shut down nuclear installations have underground systems, structures and components such as pipes, tanks or vaults. This practice of incorporating such features into the design of nuclear facilities has been in use for an extended period of time during which decommissioning was not perceived as a serious issue and was rarely considered in plant design and construction. Underground features can present formidable decontamination and/or dismantling issues, and these are addressed in this report. Decommissioning issues include, among others, difficulty of access, the possible need for remotely operated technologies, leakage of the contents and the resulting contamination of foundations and soil, as well as issues such as problematic radiological characterization. Although to date there have been more than 40 IAEA publications on decommissioning, none of them has ever addressed this subject. Although cases of decommissioning of such facilities have been described in the technical literature, no systematic treatment of relevant decommissioning strategies and technologies is currently available. It was perhaps assumed that generic decontamination and dismantling approaches would also be adequate for these 'difficult' facilities. This may be only partly true due to a number of unique physical, layout and radiological characteristics. With growing experience in the decommissioning field, it is timely to address this subject in a systematic and comprehensive fashion. Practical guidance is given in this report on relevant decommissioning strategies and technologies for underground features of facilities. Also described are alternative design and construction approaches that could facilitate a smoother path forward through the decommissioning process. The objective of this report is to highlight important points in the decommissioning of underground systems, structures or components for policy makers, operators, waste managers and other

  1. Preoperational test report, primary ventilation system

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents a preoperational test report for Primary Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space filtered venting of tanks AY101, AY102, AZ101, AZ102. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  2. Preoperational test report, primary ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-04

    This represents a preoperational test report for Primary Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space filtered venting of tanks AY101, AY102, AZ101, AZ102. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  3. 46 CFR 153.312 - Ventilation system standards.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Ventilation system standards. 153.312 Section 153.312... Handling Space Ventilation § 153.312 Ventilation system standards. A cargo handling space ventilation system must meet the following: (a) A ventilation system exhaust duct must discharge no less than 10 m...

  4. A NEW EXHAUST VENTILATION SYSTEM DESIGN SOFTWARE

    Directory of Open Access Journals (Sweden)

    H. Asilian Mahabady

    2007-09-01

    Full Text Available A Microsoft Windows based ventilation software package is developed to reduce time-consuming and boring procedure of exhaust ventilation system design. This program Assure accurate and reliable air pollution control related calculations. Herein, package is tentatively named Exhaust Ventilation Design Software which is developed in VB6 programming environment. Most important features of Exhaust Ventilation Design Software that are ignored in formerly developed packages are Collector design and fan dimension data calculations. Automatic system balance is another feature of this package. Exhaust Ventilation Design Software algorithm for design is based on two methods: Balance by design (Static pressure balance and design by Blast gate. The most important section of software is a spreadsheet that is designed based on American Conference of Governmental Industrial Hygienists calculation sheets. Exhaust Ventilation Design Software is developed so that engineers familiar with American Conference of Governmental Industrial Hygienists datasheet can easily employ it for ventilation systems design. Other sections include Collector design section (settling chamber, cyclone, and packed tower, fan geometry and dimension data section, a unit converter section (that helps engineers to deal with units, a hood design section and a Persian HTML help. Psychometric correction is also considered in Exhaust Ventilation Design Software. In Exhaust Ventilation Design Software design process, efforts are focused on improving GUI (graphical user interface and use of programming standards in software design. Reliability of software has been evaluated and results show acceptable accuracy.

  5. Underground Coal Preparation System and Applications

    Science.gov (United States)

    Wei, Cao; DeYong, Shang; BaoNing, Zhang

    2018-03-01

    The underground coal preparation is a cutting-edge technology of the coal industry worldwide. This paper introduced the meaning of implementing the underground coal preparation, and the practical applications of underground mechanical moving screen jig, underground heavy medium shallow slot and underground air jigger. Through analyzing the main separation equipment and the advantages and disadvantages of three primary processes from aspects of process complexity, slime water treatment, raw coal preparation, etc., the difference among technology investment, construction scale, production cost and economic benefit is concluded.

  6. Application of schlieren techniques for improved understanding of underground mine ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Jong, E.C.; Luxbacher, K.D. [Virginia Tech, Blacksburg, VA (United States)

    2010-07-01

    Mine ventilation systems must be maintained in optimal running order in order to suppress dusts and provide fresh air to mine workers. However, it is difficult to gather representative ventilation data because of the dynamic nature of mines, including geologic conditions, equipment operations, personnel movements, advance of mine openings and atmospheric changes. Errors and imprecision in computer codes can be detrimental to mine forecasting. The best way to improve the validity of ventilation models is to increase the quality of survey data. This study examined the feasibility of using the background-oriented schlieren (BOS) flow visualization method to reach this objective. Schlieren techniques involve the use of refractive properties of different air densities to enhance the distortions of light, thereby allowing airflow to be visualized. In this study, the BOS technique was used to image flow with 2 fans, an axivane fan and a custom built axial flow fan. The results showed that the BOS technique can clearly display air flow under the correct conditions. Producing an accurate picture of air flow can improve the industry's overall understanding of air flow and resistance, thus improving mine safety and productivity. 8 refs., 7 figs.

  7. Preoperational test report, primary ventilation condensate system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-01-29

    Preoperational test report for Primary Ventilation Condensate System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides a collection point for condensate generated by the W-030 primary vent offgas cooling system serving tanks AYIOI, AY102, AZIOI, AZI02. The system is located inside a shielded ventilation equipment cell and consists of a condensate seal pot, sampling features, a drain line to existing Catch Tank 241-AZ-151, and a cell sump jet pump. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  8. An intelligent control system for ventilators.

    Science.gov (United States)

    Wang, C S; Shaw, D; Jih, K S

    1998-10-01

    This study reports on a ventilator system that consists of several intelligent modules for controlling ventilator operation. These modules are software programs in two controllers. One controller is a personal computer used for diagnoses, determining settings and checking the effects of settings. The other controller is a single-chip microprocessor in a ventilator that controls the ventilator's settings in accordance with the computer settings. After setting up the system, an artificial lung model simulating a patient's lung is used to test the system. The result of test run indicated that it always responds to a patient's lung condition in a stable manner. Thus, the proposed system with its intelligent modules may assist clinicians in caring for patients and managing ventilator operation.

  9. Hybrid ventilation systems and high performance buildings

    Energy Technology Data Exchange (ETDEWEB)

    Utzinger, D.M. [Wisconsin Univ., Milwaukee, WI (United States). School of Architecture and Urban Planning

    2009-07-01

    This paper described hybrid ventilation design strategies and their impact on 3 high performance buildings located in southern Wisconsin. The Hybrid ventilation systems combined occupant controlled natural ventilation with mechanical ventilation systems. Natural ventilation was shown to provide adequate ventilation when appropriately designed. Proper control integration of natural ventilation into hybrid systems was shown to reduce energy consumption in high performance buildings. This paper also described the lessons learned from the 3 buildings. The author served as energy consultant on all three projects and had the responsibility of designing and integrating the natural ventilation systems into the HVAC control strategy. A post occupancy evaluation of building energy performance has provided learning material for architecture students. The 3 buildings included the Schlitz Audubon Nature Center completed in 2003; the Urban Ecology Center completed in 2004; and the Aldo Leopold Legacy Center completed in 2007. This paper included the size, measured energy utilization intensity and percentage of energy supplied by renewable solar power and bio-fuels on site for each building. 6 refs., 2 tabs., 6 figs.

  10. Hydrostatic Hyperbaric Chamber Ventilation System

    Science.gov (United States)

    Sarguisingh, Miriam J.

    2012-01-01

    The hydrostatic hyperbaric chamber (HHC) represents the merger of several technologies in development for NASA aerospace applications, harnessed to directly benefit global health. NASA has significant experience developing composite hyperbaric chambers for a variety of applications. NASA also has researched the application of water-filled vessels to increase tolerance of acceleration forces. The combination of these two applications has resulted in the hydrostatic chamber, which has been conceived as a safe, affordable means of making hyperbaric oxygen therapy (HBOT) available in the developing world for the treatment of a variety of medical conditions. Specifically, HBOT is highly-desired as a possibly curative treatment for Buruli Ulcer, an infectious condition that afflicts children in sub-Saharan Africa. HBOT is simply too expensive and too dangerous to implement in the developing world using standard equipment. The HHC technology changes the paradigm. The HHC differs from standard hyperbaric chambers in that the majority of its volume is filled with water which is pressurized by oxygen being supplied in the portion of the chamber containing the patient s head. This greatly reduces the amount of oxygen required to sustain a hyperbaric atmosphere, thereby making the system more safe and economical to operate. An effort was taken to develop an HHC system to apply HBOT to children that is simple and robust enough to support transport, assembly, maintenance and operation in developing countries. This paper details the concept for an HHC ventilation and pressurization system to provide controlled pressurization and adequate washout of carbon dioxide while the subject is enclosed in the confined space during the administration of the medical treatment. The concept took into consideration operational complexity, safety to the patient and operating personnel, and physiological considerations. The simple schematic, comprised of easily acquired commercial hardware

  11. Modelling and Simulation of Volume Controlled Mechanical Ventilation System

    Directory of Open Access Journals (Sweden)

    Yan Shi

    2014-01-01

    Full Text Available Volume controlled mechanical ventilation system is a typical time-delay system, which is applied to ventilate patients who cannot breathe adequately on their own. To illustrate the influences of key parameters of the ventilator on the dynamics of the ventilated respiratory system, this paper firstly derived a new mathematical model of the ventilation system; secondly, simulation and experimental results are compared to verify the mathematical model; lastly, the influences of key parameters of ventilator on the dynamics of the ventilated respiratory system are carried out. This study can be helpful in the VCV ventilation treatment and respiratory diagnostics.

  12. Special features of nuclear waste repository ventilation system VIS-A-VIS experiences at the Waste Isolation Pilot Plant

    International Nuclear Information System (INIS)

    Sethi, S.C.

    1991-01-01

    The paper presents an analysis and discussion of the underground ventilation system at the Waste Isolation Pilot Plant (WIPP). Particular emphasis is placed on specific repository-related requirements and the gradual evolution of engineering designs relative to the WIPP Project scope. The ventilation system for a nuclear waste facility similar to WIPP is designed to provide a suitable environment for personnel and equipment during normal activities. It is also designed to provide confinement and channeling of potential airborne radioactive material in the event of an accidental release. It is desirable to identify and design all parallel activities and the required process equipment prior to completion of the repository mine final design. Such factors as ventilation requirements, drift sizes, bulkhead sizes, and placement are dependent on these items. Mine creep closure properties must be factored into the mine and ventilation equipment design considerations. Effects of natural ventilation pressures deserve due consideration in the design. Mine ventilation requirements are dominated by the diesel equipment to be operated in the underground horizon. WIPP engineers have also found it extremely desirable to have automated real-time monitoring and control for the underground ventilation air. Final testing and balancing of the ventilation system is an extremely important startup requirement. 3 refs., 2 figs

  13. General design guide for ventilation systems for fuel reprocessing plants, September 1975

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    General safety, occupied area ventilation systems, process area ventilation systems, exhaust ventilation and filtration systems, ventilation system construction and layout ventilation system testing and monitoring, and the quality assurance program are discussed

  14. WASTE HANDLING BUILDING VENTILATION SYSTEM DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    P.A. Kumar

    2000-06-21

    The Waste Handling Building Ventilation System provides heating, ventilation, and air conditioning (HVAC) for the contaminated, potentially contaminated, and uncontaminated areas of the Monitored Geologic Repository's (MGR) Waste Handling Building (WHB). In the uncontaminated areas, the non-confinement area ventilation system maintains the proper environmental conditions for equipment operation and personnel comfort. In the contaminated and potentially contaminated areas, in addition to maintaining the proper environmental conditions for equipment operation and personnel comfort, the contamination confinement area ventilation system directs potentially contaminated air away from personnel in the WHB and confines the contamination within high-efficiency particulate air (HEPA) filtration units. The contamination confinement areas ventilation system creates airflow paths and pressure zones to minimize the potential for spreading contamination within the building. The contamination confinement ventilation system also protects the environment and the public by limiting airborne releases of radioactive or other hazardous contaminants from the WHB. The Waste Handling Building Ventilation System is designed to perform its safety functions under accident conditions and other Design Basis Events (DBEs) (such as earthquakes, tornadoes, fires, and loss of the primary electric power). Additional system design features (such as compartmentalization with independent subsystems) limit the potential for cross-contamination within the WHB. The system provides status of important system parameters and equipment operation, and provides audible and/or visual indication of off-normal conditions and equipment failures. The Waste Handling Building Ventilation System confines the radioactive and hazardous material within the building such that the release rates comply with regulatory limits. The system design, operations, and maintenance activities incorporate ALARA (as low as is

  15. 33 CFR 183.610 - Powered ventilation system.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Powered ventilation system. 183... (CONTINUED) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Ventilation § 183.610 Powered ventilation system... must: (1) Be open to the atmosphere, or (2) Be ventilated by an exhaust blower system. (b) Each exhaust...

  16. 46 CFR 153.310 - Ventilation system type.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Ventilation system type. 153.310 Section 153.310... Handling Space Ventilation § 153.310 Ventilation system type. A cargo handling space must have a permanent forced ventilation system of the exhaust type. ...

  17. 33 CFR 183.620 - Natural ventilation system.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Natural ventilation system. 183... (CONTINUED) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Ventilation § 183.620 Natural ventilation system. (a) Except for compartments open to the atmosphere, a natural ventilation system that meets the...

  18. Fires in large scale ventilation systems

    International Nuclear Information System (INIS)

    Gregory, W.S.; Martin, R.A.; White, B.W.; Nichols, B.D.; Smith, P.R.; Leslie, I.H.; Fenton, D.L.; Gunaji, M.V.; Blythe, J.P.

    1991-01-01

    This paper summarizes the experience gained simulating fires in large scale ventilation systems patterned after ventilation systems found in nuclear fuel cycle facilities. The series of experiments discussed included: (1) combustion aerosol loading of 0.61x0.61 m HEPA filters with the combustion products of two organic fuels, polystyrene and polymethylemethacrylate; (2) gas dynamic and heat transport through a large scale ventilation system consisting of a 0.61x0.61 m duct 90 m in length, with dampers, HEPA filters, blowers, etc.; (3) gas dynamic and simultaneous transport of heat and solid particulate (consisting of glass beads with a mean aerodynamic diameter of 10μ) through the large scale ventilation system; and (4) the transport of heat and soot, generated by kerosene pool fires, through the large scale ventilation system. The FIRAC computer code, designed to predict fire-induced transients in nuclear fuel cycle facility ventilation systems, was used to predict the results of experiments (2) through (4). In general, the results of the predictions were satisfactory. The code predictions for the gas dynamics, heat transport, and particulate transport and deposition were within 10% of the experimentally measured values. However, the code was less successful in predicting the amount of soot generation from kerosene pool fires, probably due to the fire module of the code being a one-dimensional zone model. The experiments revealed a complicated three-dimensional combustion pattern within the fire room of the ventilation system. Further refinement of the fire module within FIRAC is needed. (orig.)

  19. Preoperational test report, recirculation ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-11

    This represents a preoperational test report for Recirculation Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102 and supports the ability to exhaust air from each tank. Each system consists of a valved piping loop, a fan, condenser, and moisture separator; equipment is located inside each respective tank farm in its own hardened building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  20. Viewing Systems for Large Underground Storage Tanks

    International Nuclear Information System (INIS)

    Heckendorn, F.M.; Robinson, C.W.; Anderson, E.K.; Pardini, A.F.

    1996-01-01

    Specialized remote video systems have been successfully developed and deployed in a number of large radiological Underground Storage Tanks (USTs)that tolerate the hostile tank interior, while providing high resolution video to a remotely located operator. The deployment is through 100 mm (4 in) tank openings, while incorporating full video functions of the camera, lights, and zoom lens. The usage of remote video minimizes the potential for personnel exposure to radiological and hazardous conditions, and maximizes the quality of the visual data used to assess the interior conditions of both tank and contents. The robustness of this type of remote system has a direct effect on the potential for radiological exposure that personnel may encounter. The USTs typical of the Savannah River and Hanford Department Of Energy - (DOE) sites are typically 4.5 million liter (1.2 million gal) units under earth. or concrete overburden with limited openings to the surface. The interior is both highly contaminated and radioactive with a wide variety of nuclear processing waste material. Some of the tanks are -flammable rated -to Class 1, Division 1,and personnel presence at or near the openings should be minimized. The interior of these USTs must be assessed periodically as part of the ongoing management of the tanks and as a step towards tank remediation. The systems are unique in their deployment technology, which virtually eliminates the potential for entrapment in a tank, and their ability to withstand flammable environments. A multiplicity of components used within a common packaging allow for cost effective and appropriate levels of technology, with radiation hardened components on some units and lesser requirements on other units. All units are completely self contained for video, zoom lens, lighting, deployment,as well as being self purging, and modular in construction

  1. Ventilation system for 99Mo production apparatus

    International Nuclear Information System (INIS)

    Izumo, Mishiroku; Okane, Shougo; Sorita, Takami; Aoyama, Saburou

    1978-04-01

    In production of 20 Ci 99 Mo from 235 U fission, about 120 Ci of radioiodine ( 131 I, 132 I, and 133 I) is involved. To remove airborne radioiodine from the exhaust air from production apparatus and minimize radioiodine release to the atmosphere, the ventilation system is equipped with 2 units of Model-FD charcoal filter (KI 3 -Impregnated charcoal 2 inch thick of Barnebey-Cheney Co.). From September 1976 to December 1977, 21 runs of 99 Mo production involving airborne radioiodine were carried out. The ventilation system was operated continuously for the whole 15 months period; variation in removal efficiency of airborne radioiodine from the exhaust air stream was observed. In the runs valuable experiences were gained in operation and maintenance of the ventilation system including activated charcoal filter and health-physics management of such facility. Following are the results: (1) Airborne radioiodine from 99 Mo production apparatus is reduced to 10 -3 % of the original quantity. (2) When the ventilation system is operated at a maximum air flow rate through the filter, the average efficiency during 15 months is over 98%. (3) Airborne radioiodine released from 99 Mo production apparatus to the ventilation system is less than 5% particulate iodine and alkyl iodines and more than 95% inorganic iodine. (4) Airborne radioiodine released from the stack is less than 28 μCi/run, which is below the limit in regulations on Radioisotope Production Laboratory. (auth.)

  2. Fire protection in ventilation systems and in case of fire operating ventilation systems

    International Nuclear Information System (INIS)

    Zitzelsberger, J.

    1983-01-01

    The fire risks in ventilation systems are discussed. It follows a survey of regulations on fire prevention and fire protection in ventilation systems and smoke and heat exhaust systems applicable to nuclear installations in the Federal Republic of Germany. Fire protection concepts for normal systems and for systems operating also in case of fire will be given. Several structural elements for fire protection in those systems will be illustrated with regard to recent research findings

  3. Ventilation air methane destruction - the new challenge to the underground coal mining industry

    International Nuclear Information System (INIS)

    Clarke, Michael; Seddon, Duncan

    2012-01-01

    With the advent of 'Carbon Taxes' the carbon footprint of coal has become an economic as well as an environmental issue and the emission of methane in mine out- bye air as ventilation air methane (VAM) is a pending liability. As well as being economic and environmental concerns, VAM and VAM management have safety, social licence and operational factors that must also be addressed. The need to mitigate (oxidise) methane to produce carbon dioxide and water vapour (VAM destruction) and thus lower the Greenhouse footprint is coming to be seen as a necessary mining activity. However, there are several key issues to be addressed with present technology using high temperature (1000°C) thermal oxidisers. Emerging technology may involve a catalytic approach. This technology aims to lower the oxidation temperature and produce a more efficient combustion process. Several systems (based on both precious metals and transition metals) have been shown to operate below 400°C. An ultimate solution would be oxidation at ambient temperature, which is clearly demonstrated by the enzyme methane mono-oxygenase (MMO) which oxidises methane to methanol. However, the rate of oxidation at ambient temperature is too low and the structure of the bio-reactors required would be very large. The challenge is to marry the natural oxidation with modern catalytic approaches and achieve high rates of methane oxidation, in compact equipment, well below the methane auto-ignition temperature.

  4. Modeling of Energy-saving System of Conditioning Mine Air for Shallow Underground Mines

    Science.gov (United States)

    Nikolaev, Alexandr; Miftakhov, Timur; Nikolaeva, Evgeniya

    2017-11-01

    Mines of Verkhnekamsk potassium-magnesium salt deposit in Perm Krai can be subsumed under shallow mines (depth less than 500 meters). At the present moment in shallow underground mines the are problem of condensate formation in large quantities, when ventilation warm seasons of the year. This problem is more actual for salt mine, where during contact between water and potassium-magnesium ore produced electrolyte, which give rise wear of equipment. For prevent/quantity reduction condensate formation in mine used system of conditioning (refrigerating and dehumidifying) mine air (ACS). However, application this system is limited by reason of tremendous costs of electric energy for their work.

  5. Project Design Concept - Primary Ventilation System

    International Nuclear Information System (INIS)

    MCGREW, D.L.

    2000-01-01

    Tank Farm Restoration and Safe Operation (TFRSO), Project W-3 14 was established to provide upgrades that would improve the reliability and extend the system life of portions of the waste transfer, electrical, ventilation, instrumentation and control systems for the Hanford Site Tank Farms. An assessment of the tank farm system was conducted and the results are documented in system assessment reports. Based on the deficiencies identified in the tank farm system assessment reports, and additional requirements analysis performed in support of the River Protection Project (RPP), an approved scope for the TFRSO effort was developed and documented in the Upgrade Scope Summary Report (USSR), WHC-SD-W314-RPT-003, Rev. 4. The USSR establishes the need for the upgrades and identifies the specific equipment to be addressed by this project. This Project Design Concept (PDC) is in support of the Phase 2 upgrades and provides an overall description of the operations concept for the W-314 Primary Ventilation Systems. Actual specifications, test requirements, and procedures are not included in this PDC. The PDC is a ''living'' document, which will be updated throughout the design development process to provide a progressively more detailed description of the W-314 Primary Ventilation Systems design. The Phase 2 upgrades to the Primary Ventilation Systems shall ensure that the applicable current requirements are met for: Regulatory Compliance; Safety; Mission Requirements; Reliability; and Operational Requirements

  6. Advanced design of local ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Kulmala, I. [VTT Manufacturing Technology, Espoo (Finland). Safety Technology

    1997-12-31

    Local ventilation is widely used in industry for controlling airborne contaminants. However, the present design practices of local ventilation systems are mainly based on empirical equations and do not take quantitatively into account the various factors affecting the performance of these systems. The aim of this study was to determine the applicability and limitations of more advanced fluid mechanical methods to the design and development of local ventilation systems. The most important factors affecting the performance of local ventilation systems were determined and their effect was studied in a systematic manner. The numerical calculations were made with the FLUENT computer code and they were verified by laboratory experiments, previous measurements or analytical solutions. The results proved that the numerical calculations can provide a realistic simulation of exhaust openings, effects of ambient air flows and wake regions. The experiences with the low-velocity local supply air showed that these systems can also be modelled fairly well. The results were used to improve the efficiency and thermal comfort of a local ventilation unit and to increase the effective control range of exhaust hoods. In the simulation of the interaction of a hot buoyant source and local exhaust, the predicted capture efficiencies were clearly higher than those observed experimentally. The deviations between measurements and non-isothermal flow calculations may have partly been caused by the inability to achieve grid independent solutions. CFD simulations is an advanced and flexible tool for designing and developing local ventilation. The simulations can provide insight into the time-averaged flow field which may assist us in understanding the observed phenomena and to explain experimental results. However, for successful calculations the applicability and limitations of the models must be known. (orig.) 78 refs.

  7. A hybrid energy efficient building ventilation system

    International Nuclear Information System (INIS)

    Calay, Rajnish Kaur; Wang, Wen Chung

    2013-01-01

    The present paper presents a high performance cooling/heating ventilation system using a rotary heat exchanger (RHE), together with a reverse-cycle heat pump (RCHP) that can be integrated with various heat sources. Energy consumption in the building sector is largely dominated by the energy consumed in maintaining comfortable conditions indoors. For example in many developed countries the building heating, ventilation and air conditioning (HVAC) systems consume up to 50% of the total energy consumed in buildings. Therefore energy efficient HVAC solutions in buildings are critical for realising CO 2 targets at local and global level. There are many heating/cooling concepts that rely upon renewable energy sources and/or use natural low temperature heat sources in the winter and heat sinks in the summer. In the proposed system, waste energy from the exhaust air stream is used to precondition the outdoor air before it is supplied into the building. The hybrid system provides heating in the winter and cooling in the summer without any need for additional heating or cooling devices as required in conventional systems. Its performance is better than a typical reheat or air conditioning system in providing the same indoor air quality (IAQ) levels. It is shown that an energy saving up to 60% (heat energy) is achieved by using the proposed hybrid system in building ventilation applications. -- Highlights: • Hybrid ventilation system: the hybrid ventilation system uses a rotating regenerator and a reversible heat pump. • Heat recovery: heat recovery from exhaust air stream by rotary wheel type heat exchanger. • Reversible cycle heat pump (RCHP): additional heating or cooling of the supply air is provided by the RCHP. • Energy efficiency: energy savings of up to 60% using the proposed system are achievable

  8. Life cycle guideline of petrochemical plant underground piping system

    Directory of Open Access Journals (Sweden)

    Shih Jeng-Ywan

    2017-01-01

    Full Text Available According to statistics of petrochemical plant disaster, the type of underground pipeline leakage is the highest proportion, for example, Kaohsiung gas explosion in 2014 is a typical case. Therefore, improvement strategy of petrochemical plant underground piping system from both engineering and management becomes an important issue. Through reviewing regulations as well as surveying questionnaire, including kinds of piping materials, 3D drawing files, operation procedures, information sharing, etc., the findings show lack contact of integrated management with engineering executive and insufficient technical requirements are major defects. Overviewing current problems of domestic petrochemical plant underground piping system management, and comparing to international criteria and specifications, this research focuses on the of piping design, construction, operations, maintenance, and inspection. Then management procedures and engineering technical feasibility strategies are suggested. In addition, the proposed life cycle guideline in order to reduce the disaster incidence of petrochemical plant underground pipelines.

  9. Natural air ventilation in underground galleries as a tool to increase radon sampling volumes for geologic monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Eff-Darwich, Antonio [Departamento de Edafologia y Geologia, Universidad de La Laguna, Av. Astrofisico Francisco, Sanchez s/n, 38206 La Laguna, Tenerife (Spain); Instituto de Astrofisica de Canarias, c/Via Lactea s/n, 38205 La Laguna, Tenerife (Spain)], E-mail: adarwich@ull.es; Vinas, Ronaldo [Departamento de Edafologia y Geologia, Universidad de La Laguna, Av. Astrofisico Francisco, Sanchez s/n, 38206 La Laguna, Tenerife (Spain); Soler, Vicente [Estacion Volcanologica de Canarias, IPNA-CSIC, Av. Astrofisico Francisco Sanchez s/n, 38206 La Laguna, Tenerife (Spain); Nuez, Julio de la; Quesada, Maria L. [Departamento de Edafologia y Geologia, Universidad de La Laguna, Av. Astrofisico Francisco, Sanchez s/n, 38206 La Laguna, Tenerife (Spain)

    2008-09-15

    A simple numerical model was implemented to infer airflow (natural ventilation) in underground tunnels from the differences in the temporal patterns of radon, {sup 222}Rn, concentration time-series that were measured at two distant points in the interior of the tunnels. The main purpose of this work was to demonstrate that the installation of radon monitoring stations closer to the entrance of the tunnels was sufficient to remotely analyse the distribution of radon concentration in their interiors. This could ease the monitoring of radon, since the effective sampling volume of a single monitoring station located closer to the entrance of a tunnel is approximately 30,000 times larger than the sampling volume of a sub-soil radon sensor. This methodology was applied to an underground gallery located in the volcanic island of Tenerife, Canary Islands. This island constitutes an ideal laboratory to study the geo-dynamical behaviour of radon because of the existence of a vast network of galleries that conforms the main water supply of the island.

  10. Dimensionless study on dynamics of pressure controlled mechanical ventilation system

    International Nuclear Information System (INIS)

    Shi, Yan; Niu, Jinglong; Cai, Maolin; Xu, Weiqing

    2015-01-01

    Dynamics of mechanical ventilation system can be referred in pulmonary diagnostics and treatments. In this paper, to conveniently grasp the essential characteristics of mechanical ventilation system, a dimensionless model of mechanical ventilation system is presented. For the validation of the mathematical model, a prototype mechanical ventilation system of a lung simulator is proposed. Through the simulation and experimental studies on the dimensionless dynamics of the mechanical ventilation system, firstly, the mathematical model is proved to be authentic and reliable. Secondly, the dimensionless dynamics of the mechanical ventilation system are obtained. Last, the influences of key parameters on the dimensionless dynamics of the mechanical ventilation system are illustrated. The study provides a novel method to study the dynamic of mechanical ventilation system, which can be referred in the respiratory diagnostics and treatment.

  11. 46 CFR 154.1200 - Mechanical ventilation system: General.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Mechanical ventilation system: General. 154.1200 Section... CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Area: Mechanical Ventilation System § 154.1200 Mechanical ventilation system: General. (a...

  12. 46 CFR 154.1205 - Mechanical ventilation system: Standards.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Mechanical ventilation system: Standards. 154.1205... CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Cargo Area: Mechanical Ventilation System § 154.1205 Mechanical ventilation system: Standards. (a...

  13. CLASSIFICATION OF THE MGR SUBSURFACE VENTILATION SYSTEM

    International Nuclear Information System (INIS)

    R.J. Garrett

    1999-01-01

    The purpose of this analysis is to document the Quality Assurance (QA) classification of the Monitored Geologic Repository (MGR) subsurface ventilation system structures, systems and components (SSCs) performed by the MGR Safety Assurance Department. This analysis also provides the basis for revision of YMP/90-55Q, Q-List (YMP 1998). The Q-List identifies those MGR SSCs subject to the requirements of DOE/RW-0333P7 ''Quality Assurance Requirements and Description'' (QARD) (DOE 1998)

  14. Mont Terri Project - Ventilation experiment in Opalinus Clay for the disposal of radioactive waste in underground repositories

    Energy Technology Data Exchange (ETDEWEB)

    Mayor, J. C. [Empresa Nacional de Residuos Radioactivos SA (ENRESA), Madrid (Spain); Garcia-Sineriz, J. [Asociacion para la Investigacion y Desarollo Industrial de los Recursos Naturales (AITEMIN), Madrid (Spain); Velasco, M. [DM Iberia SA, Madrid (Spain); Gomez-Hernandez, J. [Ingenieria Hidraulica y Medio Ambiente, Escuela de Ingenieros de Caminos (UPV), Valencia (Spain); Lloret, A.; Matray, J.-M. [IRSN/DEI/SARG/LETS, Fontenay-aux-Roses (France); Coste, F. [Aradis ESG, Sevres Cedex (France); Giraud, A. [LAEGO-ENSG, Vandoeuvre les Nancy (France); Rothfuchs, T. [Gesellschaft fuer Anlagen und Reaktorsicherheit mbH (GRS), Braunschweig (Germany); Marschall, P. [National Cooperative for the Disposal of Radioactive Waste (Nagra), Wettingen (Switzerland); Roesli, U. [Solexperts AG, Moenchaltorf (Switzerland); Mayer, G. [Colenco Power Engineering Ltd, Baden (Switzerland)

    2007-07-01

    The ventilation of the underground drifts during the construction and operation of a radioactive waste repository could produce the partial desaturation of the rock around the drifts, modifying its thermo-hydro-mechanical properties, especially in clayey rocks. This change of rock properties may have an impact on the design of the repositories (drifts spacing and repository size), which depends on the thermal load that the clay barrier and the rock can accept. To evaluate 'in situ' and better understand the desaturation process of a hard clay formation, the Ventilation Experiment (VE) has been carried out at the Mont Terri underground laboratory (Switzerland), generating a flow of dry air during several months along a section of a microtunnel. Specifically, the VE test has been performed, under practically isothermal conditions (T {approx_equal} 15-16 {sup o}C), in a 10 m long section of a non-lined horizontal microtunnel (diameter = 1.3 m), excavated in 1999 in the shaly facies of the Opalinus Clay of Mont Terri. The microtunnel is oriented perpendicular to the bedding strike direction of the rock (mean value of the bedding dip {approx_equal} 25{sup o}). The VE experiment real data and its modelling have shown that the desaturation of clayey rocks of low hydraulic conductivity (K < 10{sup -12} m/s) due to ventilation is very small. Under real repository conditions, the thermal and hydro-mechanical rock characteristics will not be practically affected by the ventilation. Specifically, the monitoring of the VE test (mainly the hygrometer data, confirmed also by the geoelectrical measurements) indicates that, after about 5 months of ventilation with almost dry air, the rock relative humidity (and then the degree of saturation) was less than 95% only in a ring of thickness less than 40 cm. Nevertheless, a suction state (subatmospheric liquid pressures) developed up to a distance of about 2 m, but it should be kept in mind that a clayey rock such as the

  15. 75 FR 5009 - Proximity Detection Systems for Underground Mines

    Science.gov (United States)

    2010-02-01

    ... Proximity Detection Systems for Underground Mines AGENCY: Mine Safety and Health Administration, Labor... information regarding whether the use of proximity detection systems would reduce the risk of accidents where... . Information on MSHA-approved proximity detection systems is available on the Internet at http://www.msha.gov...

  16. Ventilation systems in houses. Special issue; Woonhuisventilatie. Special

    Energy Technology Data Exchange (ETDEWEB)

    Op ' t Veld, P.; Van der Aa, A. [Cauberg-Huygen Raadgevend Ingenieurs, Rotterdam (Netherlands); Verschoor, M.J.E. [Afdeling Koudetechniek en Warmtepompen, TNO Milieu, Energie en Procesinnovatie TNO-MEP, Apeldoorn (Netherlands); Van Gulik, L.H. [Itho, Scheidam (Netherlands); Van der Mark, K.; Overman, P. [AGPO, Breda (Netherlands); Roemer, J.C.; Schuitema, R. [ECN Duurzame Energie in de Gebouwde Omgeving DEGO, Petten (Netherlands); Weterings, M. [GGD voor Rotterdam e.o., Rotterdam (Netherlands); Rosenmai, T.; Rasmussen, S. [Copenhagen Business School, Copenhagen (Denmark); Vollebregt, R. [Bureau Kent, Utrecht (Netherlands); Smeets, L.J.M. [Nederlandse onderneming voor energie en milieu Novem, Utrecht (Netherlands)

    2001-06-01

    In 10 articles attention is paid to several aspects with respect to ventilation of houses. This issue includes an overview of suppliers of high-efficiency heat recovering balanced ventilation systems.

  17. 40 CFR 280.220 - Ownership of an underground storage tank or underground storage tank system or facility or...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Ownership of an underground storage... underground storage tank system is located. 280.220 Section 280.220 Protection of Environment ENVIRONMENTAL... as defined in § 280.210; and (b) Does not engage in petroleum production, refining, and marketing as...

  18. Modification of the ventilation system at Waste Isolation Pilot Plant (WIPP)

    International Nuclear Information System (INIS)

    Sethi, S.C.

    1987-01-01

    The WIPP (Waste Isolation Pilot Plant) Project near Carlsbad, New Mexico, is a research and development project sponsored by the US Department of Energy, designed to demonstrate the safe disposal of radioactive waste. A mine (repository) is being developed 2,150 feet below the surface in a thick salt bed, which will serve as the disposal medium. The underground ventilation system for the WIPP project was originally designed based on a fixed project scope. The design criteria and ventilation requirements were developed for the performance of various activities as then envisioned towards the achievement of this goal. However, in light of new information and actual site-specific experience at WIPP leading to a clearer definition of the scope-related programs and activities, it was realized that the existing ventilation system may need to be modified

  19. Risk analysis and reliability of the GERDA Experiment extraction and ventilation plant at Gran Sasso mountain underground laboratory of Italian National Institute for Nuclear Physics

    Energy Technology Data Exchange (ETDEWEB)

    Lombardi, Mara; Garzia, Fabio; Guarascio, Massimo; Giovannone, Enzo Paolo; Giampaoli, Antonio; Musti, Mafalda; Ranalli, Maria Teresa; Perruzza, Roberto; Tartaglia, Roberto, E-mail: mara.lombardi@uniroma1.it, E-mail: fabio.garzia@uniroma1.it, E-mail: massimo.guarascio@uniroma1.it [Universita degli Studi di Roma La Sapienza-Engineering Roma (Italy); Corpo Nazionale Vigili del Fuoco L' Aquila (CNVF) (Italy); Istituto Nazionale di Fisica Nucleare - Laboratori del Gran Sasso L' Aquila, Abruzzo (Italy)

    2017-07-15

    The aim of this study is the risk analysis evaluation about argon release from the GERDA experiment in the Gran Sasso underground National Laboratories (LNGS) of the Italian National Institute for Nuclear Physics (INFN). The GERDA apparatus, located in Hall A of the LNGS, is a facility with germanium detectors located in a wide tank filled with about 70 m{sup 3} of cold liquefied argon. This cryo-tank sits in another water-filled tank (700 m{sup 3} ) at atmospheric pressure. In such cryogenic processes, the main cause of an accidental scenario is lacking insulation of the cryo-tank. A preliminary HazOp analysis has been carried out on the whole system. The risk assessment identified two possible top-events: explosion due to a Rapid Phase Transition - RPT and argon runaway evaporation. Risk analysis highlighted a higher probability of occurrence of the latter top event. To avoid emission in Hall A, the HazOp, Fault Tree and Event tree analyses of the cryogenic gas extraction and ventilation plant have been made. The failures related to the ventilation system are the main cause responsible for the occurrence. To improve the system reliability some corrective actions were proposed: the use of UPS and the upgrade of damper opening devices. Furthermore, the Human Reliability Analysis identified some operating and management improvements: action procedure optimization, alert warnings and staff training. The proposed model integrates the existing analysis techniques by applying the results to an atypical work environment and there are useful suggestions for improving the system reliability. (author)

  20. An ultrasonic-based localization system for underground mines

    CSIR Research Space (South Africa)

    Jordaan, JP

    2017-07-01

    Full Text Available -based localization system for underground mines 2017 IEEE 15th International Conference on Industrial Informatics (INDIN), 24-26 July 2017, Emden, Germany JP Jordaan, CP Kruger, BJ Silva and GP Hancke Abstract: Localization is important for a wide range...

  1. PUREX exhaust ventilation system installation test report

    International Nuclear Information System (INIS)

    Blackaby, W.B.

    1997-01-01

    This Acceptance Test Report validates the testing performed, the exceptions logged and resolved and certifies this portion of the SAMCONS has met all design and test criteria to perform as an operational system. The proper installation of the PUREX exhaust ventilation system components and wiring was systematically evaluated by performance of this procedure. Proper operation of PUREX exhaust fan inlet, outlet, and vortex damper actuators and limit switches were verified, using special test equipment, to be correct and installed wiring connections were verified by operation of this equipment

  2. A validated numerical investigation of the effects of high blockage ratio and train and tunnel length upon underground railway aerodynamics

    OpenAIRE

    Cross, D.; Hughes, B.; Ingham, D.; Ma, L.

    2015-01-01

    In order to ensure the safety and comfort of passengers and staff, an underground railway requires an extensive ventilation and cooling system. One mechanism for underground railway ventilation is the movement of air induced by trains, termed the ‘piston effect’. This study investigated the effect of altering the blockage ratio of an underground train upon the ventilating air flows driven by a train. First a computational model was developed and validated with experimental data from literatur...

  3. Performance assessment for underground radioactive waste disposal systems

    International Nuclear Information System (INIS)

    1985-01-01

    A waste disposal system comprises a number of subsystems and components. The performance of most systems can be demonstrated only indirectly because of the long period that would be required to test them. This report gives special attention to performance assessment of subsystems within the total waste disposal system, and is an extension of an IAEA report on Safety Assessment for the Underground Disposal of Radioactive Wastes

  4. Hybrid Ventilation with Innovative Heat Recovery—A System Analysis

    Directory of Open Access Journals (Sweden)

    Bengt Hellström

    2013-02-01

    Full Text Available One of the most important factors when low energy houses are built is to have good heat recovery on the ventilation system. However, standard ventilation units use a considerable amount of electricity. This article discusses the consequences on a system level of using hybrid ventilation with heat recovery. The simulation program TRNSYS was used in order to investigate a ventilation system with heat recovery. The system also includes a ground source storage and waste water heat recovery system. The result of the analysis shows that the annual energy gain from ground source storage is limited. However, this is partly a consequence of the fact that the well functioning hybrid ventilation system leaves little room for improvements. The analysis shows that the hybrid ventilation system has potential to be an attractive solution for low energy buildings with a very low need for electrical energy.

  5. Tracer gas evaluations of push-pull ventilation system performance.

    Science.gov (United States)

    Ojima, Jun

    2009-01-01

    A push-pull ventilation system is effective for hazardous material exhaustion. Although a push-pull ventilation system has advantages over a local exhaust hood, some laborious adjustments are required. The pertinence of the adjustments is uncertain because it is difficult to evaluate the performance of a push-pull ventilation system quantitatively. In this study, a measurement of the capture efficiency of a push-pull ventilation system was carried out by means of a tracer gas method. The capture efficiency decreased to 39.3-78.5% when blockage material, a dummy worker and a cross draft, were set in the ventilation zone, but the efficiency was 95.1-97.9% when the cross draft was stopped. The results suggest that the uniform flow of a push-pull ventilation system will detour a blockage and the performance of the system will not be reduced unless a cross draft disturbs the uniform flow.

  6. Position paper -- Tank ventilation system design air flow rates

    International Nuclear Information System (INIS)

    Goolsby, G.K.

    1995-01-01

    The purpose of this paper is to document a project position on required ventilation system design air flow rates for the waste storage tanks currently being designed by project W-236A, the Multi-Function Waste Tank Facility (MWTF). The Title 1 design primary tank heat removal system consists of two systems: a primary tank vapor space ventilation system; and an annulus ventilation system. At the conclusion of Title 1 design, air flow rates for the primary and annulus ventilation systems were 960 scfm and 4,400 scfm, respectively, per tank. These design flow rates were capable of removing 1,250,000 Btu/hr from each tank. However, recently completed and ongoing studies have resulted in a design change to reduce the extreme case heat load to 700,000 Btu/hr. This revision of the extreme case heat load, coupled with results of scale model evaporative testing performed by WHC Thermal Hydraulics, allow for a reduction of the design air flow rates for both primary and annulus ventilation systems. Based on the preceding discussion, ICF Kaiser Hanford Co. concludes that the design should incorporate the following design air flow rates: Primary ventilation system--500 scfm maximum and Annulus ventilation system--1,100 scfm maximum. In addition, the minimum air flow rates in the primary and annulus ventilation systems will be investigated during Title 2 design. The results of the Title 2 investigation will determine the range of available temperature control using variable air flows to both ventilation systems

  7. Performance potential of mechanical ventilation systems with minimized pressure loss

    DEFF Research Database (Denmark)

    Terkildsen, Søren; Svendsen, Svend

    2013-01-01

    In many locations mechanical ventilation has been the most widely used principle of ventilation over the last 50 years but the conventional system design must be revised to comply with future energy requirements. This paper examines the options and describes a concept for the design of mechanical....... This corresponds to 10-15% of the power consumption for conventional mechanical ventilation systems thus enabling the system to fulfil future energy requirements in buildings....... ventilation systems with minimal pressure loss and minimal energy use. This can provide comfort ventilation and avoid overheating through increased ventilation and night cooling. Based on this concept, a test system was designed for a fictive office building and its performance was documented using building...

  8. 76 FR 70075 - Proximity Detection Systems for Continuous Mining Machines in Underground Coal Mines

    Science.gov (United States)

    2011-11-10

    ... Detection Systems for Continuous Mining Machines in Underground Coal Mines AGENCY: Mine Safety and Health... proposed rule addressing Proximity Detection Systems for Continuous Mining Machines in Underground Coal... Detection Systems for Continuous Mining Machines in Underground Coal Mines. MSHA conducted hearings on...

  9. Numerical modeling of underground storage system for natural gas

    Science.gov (United States)

    Ding, J.; Wang, S.

    2017-12-01

    Natural gas is an important type of base-load energy, and its supply needs to be adjusted according to different demands in different seasons. For example, since natural gas is increasingly used to replace coal for winter heating, the demand for natural gas in winter is much higher than that in other seasons. As storage systems are the essential tools for balancing seasonal supply and demand, the design and simulation of natural gas storage systems form an important research direction. In this study, a large-scale underground storage system for natural gas is simulated based on theoretical analysis and finite element modeling.It is proven that the problem of axi-symmetric Darcy porous flow of ideal gas is governed by the Boussinesq equation. In terms of the exact solution to the Boussinesq equation, the basic operating characteristics of the underground storage system is analyzed, and it is demonstrated that the propagation distance of the pore pressure is proportional to the 1/4 power of the mass flow rate and to the 1/2 power of the propagation time. This quantitative relationship can be used to guide the overall design of natural gas underground storage systems.In order to fully capture the two-way coupling between pore pressure and elastic matrix deformation, a poro-elastic finite element model for natural gas storage is developed. Based on the numerical model, the dynamic processes of gas injection, storage and extraction are simulated, and the corresponding time-dependent surface deformations are obtained. The modeling results not only provide a theoretical basis for real-time monitoring for the operating status of the underground storage system through surface deformation measurements, but also demonstrate that a year-round balance can be achieved through periodic gas injection and extraction.This work is supported by the CAS "100 talents" Program and the National Natural Science Foundation of China (41371090).

  10. Advanced Controls for Residential Whole-House Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Turner, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-01

    Whole-house ventilation systems are becoming commonplace in new construction, remodeling/renovation, and weatherization projects, driven by combinations of specific requirements for indoor air quality (IAQ), health and compliance with standards, such as ASHRAE 62.2. Ventilation systems incur an energy penalty on the home via fan power used to drive the airflow, and the additional space-conditioning load associated with heating or cooling the ventilation air. Finding a balance between IAQ and energy use is important if homes are to be adequately ventilated while not increasing the energy burden. This study used computer simulations to examine RIVEC the Residential Integrated Ventilation Controller - a prototype ventilation controller that aims to deliver whole-house ventilation rates that comply with ventilation standards, for the minimum use of energy. Four different whole-house ventilation systems were simulated, both with and without RIVEC, so that the energy and IAQ results could be compared. Simulations were conducted for 13 US climate zones, three house designs, and three envelope leakage values. The results showed that the RIVEC controller could typically return ventilation energy savings greater than 40percent without compromising long-term chronic or short-term acute exposures to relevant indoor contaminants. Critical and average peak power loads were also reduced as a consequence of using RIVEC.

  11. Mixing Ventilation System in a Single-Aisle Aircraft Cabin

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Zhang, Chen; Wojcik, Kamil

    2014-01-01

    and present a design procedure of the system. Finally, a personalised ventilation system will be described, which can be used together with the mixing ventilation system. The experiments are made in a full-scale, left side mock-up of a single-aisle (Boeing 737) cabin with four seats. The four passengers...

  12. 76 FR 63238 - Proximity Detection Systems for Continuous Mining Machines in Underground Coal Mines

    Science.gov (United States)

    2011-10-12

    ... Detection Systems for Continuous Mining Machines in Underground Coal Mines AGENCY: Mine Safety and Health... proposed rule for Proximity Detection Systems on Continuous Mining Machines in Underground Coal Mines. Due... Underground Coal Mines, published on August 31, 2011. DATES: The public hearing dates and locations are listed...

  13. Ventilation Systems Operating Experience Review for Fusion Applications

    International Nuclear Information System (INIS)

    Cadwallader, L.C.

    1999-01-01

    This report is a collection and review of system operation and failure experiences for air ventilation systems in nuclear facilities. These experiences are applicable for magnetic and inertial fusion facilities since air ventilation systems are support systems that can be considered generic to nuclear facilities. The report contains descriptions of ventilation system components, operating experiences with these systems, component failure rates, and component repair times. Since ventilation systems have a role in mitigating accident releases in nuclear facilities, these data are useful in safety analysis and risk assessment of public safety. An effort has also been given to identifying any safety issues with personnel operating or maintaining ventilation systems. Finally, the recommended failure data were compared to an independent data set to determine the accuracy of individual values. This comparison is useful for the International Energy Agency task on fusion component failure rate data collection

  14. An Effective Belt Conveyor for Underground Ore Transportation Systems

    Science.gov (United States)

    Krol, Robert; Kawalec, Witold; Gladysiewicz, Lech

    2017-12-01

    Raw material transportation generates a substantial share of costs in the mining industry. Mining companies are therefore determined to improve the effectiveness of their transportation system, focusing on solutions that increase both its energy efficiency and reliability while keeping maintenance costs low. In the underground copper ore operations in Poland’s KGHM mines vast and complex belt conveyor systems have been used for horizontal haulage of the run-of-mine ore from mining departments to shafts. Basing upon a long-time experience in the field of analysing, testing, designing and computing of belt conveyor equipment with regard to specific operational conditions, the improvements to the standard design of an underground belt conveyor for ore transportation have been proposed. As the key elements of a belt conveyor, the energy-efficient conveyor belt and optimised carrying idlers have been developed for the new generation of underground conveyors. The proposed solutions were tested individually on the specially constructed test stands in the laboratory and in the experimental belt conveyor that was built up with the use of prototype parts and commissioned for the regular ore haulage in a mining department in the KGHM underground mine “Lubin”. Its work was monitored and the recorded operational parameters (loadings, stresses and strains, energy dissipation, belt tracking) were compared with those previously collected on a reference (standard) conveyor. These in-situ measurements have proved that the proposed solutions will return with significant energy savings and lower maintenance costs. Calculations made on the basis of measurement results in the specialized belt conveyor designing software allow to estimate the possible savings if the modernized conveyors supersede the standard ones in a large belt conveying system.

  15. Measure Guideline: Selecting Ventilation Systems for Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, Robb [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-02-01

    This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

  16. Thermal analysis of a kitchen natural ventilation system with ...

    African Journals Online (AJOL)

    A numerical study was conducted to perform the design analysis of a novel kitchen natural ventilation system of Madirelo Hotel School. The analysis was performed by using Computational Fluid Dynamics to assess the performance of natural ventilation system. The design is expected to be energy efficient and cost effective ...

  17. Uncertainties in different level assessments of domestic ventilation systems

    NARCIS (Netherlands)

    Bokel, R.M.J.; Yang, Z.; Cauberg, J.J.M.

    2013-01-01

    In order to improve the quality of ventilation systems, assessments are widely used. In this paper, 3 main assessment levels are distinguished based on the number of ventilation systems to be assessed and the assessment objective. The main assessment levels distinguished in this paper are global

  18. An Overview of National Trends Related to Innovative Ventilation Systems

    DEFF Research Database (Denmark)

    Heijmans, Nicolas; Wouters, Peter; Heiselberg, Per

    2008-01-01

    This paper summarises the discussion related to innovative (ventilation) systems that took place at the AIVC workshop organised in Ghent, Belgium, in March 2008.......This paper summarises the discussion related to innovative (ventilation) systems that took place at the AIVC workshop organised in Ghent, Belgium, in March 2008....

  19. Ventilation systems as an effective tool for control of radon daughter concentration in mines

    International Nuclear Information System (INIS)

    Dory, A.B.

    1981-10-01

    Experience in mines shows that a very high concentration of radon daughters builds up in an unventilated dead end heading. Even minimal air movement results in a drastic reduction in radon daughter concentration. Designing the ventilation system to provide an optimized flow of fresh air into the workplace results in acceptable climatic conditions and radon daughter levels. The example of the Director fluorospar mine in Newfoundland is used to illustrate the actual design and operation of a ventilation system that provided effective radon daughter control. It was found at this mine that the age of the air underground should be kept as low as possible; that no areas of the mine should be left unventilated unless they could be kept at negative pressure; that a comparatively simple remote control and monitoring system helped stabilize ventilation and detected upsets; that the ventilation system should operate continuously, even when the mine is shut down for short periods; and that pressurization of the mine seemed to inhibit radon influx

  20. Auxiliary mine ventilation manual

    International Nuclear Information System (INIS)

    Workplace Safety North

    2010-01-01

    An adequate ventilation system is needed for air quality and handling in a mine and is comprised of many different pieces of equipment for removing contaminated air and supplying fresh air and thereby provide a satisfactory working environment. This manual highlights auxiliary ventilation systems made up of small fans, ducts, tubes, air movers, deflectors and additional air flow controls which distribute fresh air delivered by the primary system to all areas. A review of auxiliary ventilation is provided. Design, operation and management issues are discussed and guidelines are furnished. This manual is limited to underground hard rock operations and does not address directly other, specific auxiliary systems, either in underground coal mines or uranium mines.

  1. Fire protection countermeasures for containment ventilation systems

    International Nuclear Information System (INIS)

    Alvares, N.J.; Beason, D.G.; Bergman, W.; Ford, H.W.; Lipska, A.E.

    1980-01-01

    The goal of this project is to find countermeasures to protect HEPA filters in exit ventilation ducts from the heat and smoke generated by fire. Several methods for partially mitigating the smoke exposure to the HEPA filters were identified through testing and analysis. These independently involve controlling the fuel, controlling the fire, and intercepting the smoke aerosol prior to its sorption on the HEPA filter. Exit duct treatment of aerosols is not unusual in industrial applications and involves the use of scrubbers, prefilters, and inertial impaction, depending on the size, distribution, and concentration of the subject aerosol. However, when these unmodified techniques were applied to smoke aerosols from fires on materials, common to experimental laboratories of LLNL, it was found they offered minimal protection to the HEPA filters. Ultimately, a continuous, movable, high-efficiency prefilter using modified commercial equipment was designed. This technique is capable of protecting HEPA filters over the total duration of the test fires. The reason for success involved the modificaton of the prefiltration media. Commercially available filter media has a particle sorption efficiency that is inversely proportional to media strength. To achieve properties of both efficiency and strength, we laminated rolling filter media with the desired properties. It is not true that the use of rolling prefilters solely to protect HEPA filters from fire-generated smoke aerosols is cost effective in every type of containment system, especially if standard fire-protection systems are available in the space. But in areas of high fire risk, where the potential fuel load is large and ignition sources are plentiful, the complication of a rolling prefilter in exit ventilation ducts to protect HEPA filters from smoke aerosols is definitely justified

  2. Performance potential of mechanical ventilation systems with minimized pressure loss

    DEFF Research Database (Denmark)

    Terkildsen, Søren; Svendsen, Svend

    2013-01-01

    simulations that quantify fan power consumption, heating demand and indoor environmental conditions. The system was designed with minimal pressure loss in the duct system and heat exchanger. Also, it uses state-of-the-art components such as electrostatic precipitators, diffuse ceiling inlets and demand......In many locations mechanical ventilation has been the most widely used principle of ventilation over the last 50 years but the conventional system design must be revised to comply with future energy requirements. This paper examines the options and describes a concept for the design of mechanical...... ventilation systems with minimal pressure loss and minimal energy use. This can provide comfort ventilation and avoid overheating through increased ventilation and night cooling. Based on this concept, a test system was designed for a fictive office building and its performance was documented using building...

  3. Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation, Somerville, MA (United States); Bergey, Daniel [Building Science Corporation, Somerville, MA (United States)

    2014-02-01

    In this project, Building America research team Building Science Corporation tested the effectiveness of ventilation systems at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. This was because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four system factor categories: balance, distribution, outside air source, and recirculation filtration. Recommended system factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

  4. Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bergey, Daniel [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-02-01

    Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. It was inferior because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

  5. Investigation of the ventilation performance of an integrated day lighting natural ventilation system

    International Nuclear Information System (INIS)

    Ahmed, S.; Abdul Rahman, S.; Ahmed, A.Z.

    2006-01-01

    Natural ventilation and daylighting are two passive strategies that can improve the indoor performance as well as reduce energy consumption in buildings. Both strategies when used appropriately, increase indoor quality and comport. In terms of energy costs, daylighting can significantly reduce artificial lighting as well as heat dissipated from the resulting fixtures while natural ventilation can minimize the need for air-conditioning. A study is currently being conducted to develop a system that integrates these two passive strategies, to be used specifically for buildings in Malaysia. The initial proposed integrated models are based on similar studies already conducted but with appropriate modifications for tropical climates. This paper will present some results of the ventilation performance of the proposed integrated system model, particularly the airflow distribution patterns and air speed, inside a naturally ventilated room. A CFD simulation software was used to investigate the optimum size of the integrated model with regards to interior ventilation performance. The simulations also included single sided and cross ventilated openings

  6. Close out of the Malargue site: Underground draining system

    International Nuclear Information System (INIS)

    Giordano, Nolberto N.; Liseno, Aldo

    2000-01-01

    An industrial uranium production facility stopped working in Malargue city, Mendoza province. Nowadays, in that place there are 700,000 tons of solid tailings piles from the uranium minerals concentration process. They must be treated inside the site through engineering works included in the final closeout project. This paper describes the project technical details of an underground drainage system, designed to depress the groundwater level and to be sure about the isolation of the solids to be treated from the groundwater. The work was done by a private company, after public bidding process. At the moment the drainage system is in operation control stage. (author)

  7. Monitoring and information management system at the Underground Research Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Strobel, G.S.; Chernis, P.J.; Bushman, A.T.; Spinney, M.H.; Backer, R.J. [Atomic Energy of Canada Limited, Pinawa, Manitoba (Canada)

    1996-07-01

    Atomic Energy of Canada Limited (AECL) has developed a customer oriented monitoring and information management system at the Underground Research Laboratory (URL) near Lac du Bonnet, Manitoba. The system is used to monitor instruments and manage, process, and distribute data. It consists of signal conditioners and remote loggers, central schedule and control systems, computer aided design and drafting work centres, and the communications linking them. The monitoring and communications elements are designed to meet the harsh demands of underground conditions while providing accurate monitoring of sensitive instruments to rigorous quality assured specifications. These instruments are used for testing of the concept for the deep geological disposal of nuclear fuel waste as part of the Canadian Nuclear Fuel Waste Management Program. Many of the tests are done in situ and at full-scale. The monitoring and information management system services engineering, research, and support staff working to design, develop, and demonstrate and present the concept. Experience gained during development of the monitoring and information management system at the URL, can be directly applied at the final disposal site. (author)

  8. Monitoring and information management system at the Underground Research Laboratory

    International Nuclear Information System (INIS)

    Strobel, G.S.; Chernis, P.J.; Bushman, A.T.; Spinney, M.H.; Backer, R.J.

    1996-01-01

    Atomic Energy of Canada Limited (AECL) has developed a customer oriented monitoring and information management system at the Underground Research Laboratory (URL) near Lac du Bonnet, Manitoba. The system is used to monitor instruments and manage, process, and distribute data. It consists of signal conditioners and remote loggers, central schedule and control systems, computer aided design and drafting work centres, and the communications linking them. The monitoring and communications elements are designed to meet the harsh demands of underground conditions while providing accurate monitoring of sensitive instruments to rigorous quality assured specifications. These instruments are used for testing of the concept for the deep geological disposal of nuclear fuel waste as part of the Canadian Nuclear Fuel Waste Management Program. Many of the tests are done in situ and at full-scale. The monitoring and information management system services engineering, research, and support staff working to design, develop, and demonstrate and present the concept. Experience gained during development of the monitoring and information management system at the URL, can be directly applied at the final disposal site. (author)

  9. Evaluation of energy system analysis techniques for identifying underground facilities

    Energy Technology Data Exchange (ETDEWEB)

    VanKuiken, J.C.; Kavicky, J.A.; Portante, E.C. [and others

    1996-03-01

    This report describes the results of a study to determine the feasibility and potential usefulness of applying energy system analysis techniques to help detect and characterize underground facilities that could be used for clandestine activities. Four off-the-shelf energy system modeling tools were considered: (1) ENPEP (Energy and Power Evaluation Program) - a total energy system supply/demand model, (2) ICARUS (Investigation of Costs and Reliability in Utility Systems) - an electric utility system dispatching (or production cost and reliability) model, (3) SMN (Spot Market Network) - an aggregate electric power transmission network model, and (4) PECO/LF (Philadelphia Electric Company/Load Flow) - a detailed electricity load flow model. For the purposes of most of this work, underground facilities were assumed to consume about 500 kW to 3 MW of electricity. For some of the work, facilities as large as 10-20 MW were considered. The analysis of each model was conducted in three stages: data evaluation, base-case analysis, and comparative case analysis. For ENPEP and ICARUS, open source data from Pakistan were used for the evaluations. For SMN and PECO/LF, the country data were not readily available, so data for the state of Arizona were used to test the general concept.

  10. On analysis of operating efficiency of autonomous ventilation systems

    Directory of Open Access Journals (Sweden)

    Kostuganov Arman

    2017-01-01

    Full Text Available The paper deals with the causes and consequences of malfunctioning of natural and mechanical ventilation systems in civil buildings of Russia. Furthermore it gives their classification and analysis based on the literature review. On the basis of the analysis technical solutions for improving the efficiency of ventilation systems in civil buildings are summarized and the field of their application is specified. Among the offered technical solutions the use of autonomous ventilation systems with heat recovery is highlighted as one of the most promising and understudied. Besides it has a wide range of applications. The paper reviews and analyzes the main Russian and foreign designs of ventilation systems with heat recovery that are mostly used in practice. Three types of such systems: UVRK-50, Prana-150, ТеFо are chosen for consideration. The sequence of field tests of selected autonomous ventilation systems have been carried out in order to determine the actual air exchange and efficiency of heat recovery. The paper presents the processed results of the research on the basis of which advantages and disadvantages of the tested ventilation systems are identified and recommendations for engineering and manufacturing of new design models of autonomous ventilation systems with heat recovery are formulated.

  11. Wireless system for explosion detection in underground structures

    Science.gov (United States)

    Chikhradze, M.; Bochorishvili, N.; Akhvlediani, I.; Kukhalashvili, D.; Kalichava, I.; Mataradze, E.

    2009-06-01

    Considering the growing threat of terrorist or accidental explosions in underground stations, underground highway and railway sections improvement of system for protecting people from explosions appears urgent. Current automatic protective devices with blast identification module and blast damping absorbers of various designs as their basic elements cannot be considered effective. Analysis revealed that low reliability of blast detection and delayed generation of start signal for the activation of an absorber are the major disadvantages of protective devices. Besides the transmission of trigger signal to an energy absorber through cable communication reduces the reliability of the operation of protective device due to a possible damage of electric wiring under blast or mechanical attack. This paper presents the outcomes of the studies conducted to select accurate criteria for blast identification and to design wireless system of activation of defensive device. The results of testing of blast detection methods (seismic, EMP, optical, on overpressure) showed that the proposed method, which implies constant monitoring of overpressure in terms of its reliability and response speed, best meets the requirements. Proposed wireless system for explosions identification and activation of protective device consists of transmitter and receiver modules. Transmitter module contains sensor and microprocessor equipped with blast identification software. Receiver module produces activation signal for operation of absorber. Tests were performed in the underground experimental base of Mining Institute. The time between the moment of receiving signal by the sensor and activation of absorber - 640 microsecond; distance between transmitter and receiver in direct tunnel - at least 150m; in tunnel with 900 bending - 50m. This research is sponsored by NATO's Public Diplomacy Division in the framework of "Science for Peace".

  12. High Voltage AC underground cable systems for power transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper is a second of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last six years. The main core of the results are obtained by PhD students resea...... to resonances. Part II covers transient phenomena, harmonics in cables, system modelling for different phenomena, main and backup protections in cable-based networks, online fault detection and future trends....

  13. High Voltage AC underground cable systems for power transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2016-01-01

    This paper is a first of two presenting a review of research results in underground cable transmission obtained by the Department of Energy Technology, Aalborg University ET/AAU and Danish TSO Energinet.dk within the last 6 years. The main core of the results are obtained by PhD students research...... to resonances. Part II covers transient phenomena, harmonics in cables, system modelling for different phenomena, main and backup protections in cable-based networks, online fault detection and future trends....

  14. Radon in an underground cave system in Victoria

    International Nuclear Information System (INIS)

    Hedt, J.C.; Boal, T.J.

    1998-01-01

    Radon levels in a cave system in Victoria have been measured. The variation of radon and radon progeny levels with time, position throughout the cave and season have been determined. The radiation exposure of tour guides were estimated. The data is being used to develop a radiation management plan for the tour guides. Radon concentration within a cave system was proven to be dependent to a large extent upon the rate of air exchange with outside. Cave ventilation is the single most important factor in determining if there is diurnal variation in the radon concentration

  15. Specialized video systems for use in underground storage tanks

    International Nuclear Information System (INIS)

    Heckendom, F.M.; Robinson, C.W.; Anderson, E.K.; Pardini, A.F.

    1994-01-01

    The Robotics Development Groups at the Savannah River Site and the Hanford site have developed remote video and photography systems for deployment in underground radioactive waste storage tanks at Department of Energy (DOE) sites as a part of the Office of Technology Development (OTD) program within DOE. Figure 1 shows the remote video/photography systems in a typical underground storage tank environment. Viewing and documenting the tank interiors and their associated annular spaces is an extremely valuable tool in characterizing their condition and contents and in controlling their remediation. Several specialized video/photography systems and robotic End Effectors have been fabricated that provide remote viewing and lighting. All are remotely deployable into and from the tank, and all viewing functions are remotely operated. Positioning all control components away from the facility prevents the potential for personnel exposure to radiation and contamination. Overview video systems, both monaural and stereo versions, include a camera, zoom lens, camera positioner, vertical deployment system, and positional feedback. Each independent video package can be inserted through a 100 mm (4 in.) diameter opening. A special attribute of these packages is their design to never get larger than the entry hole during operation and to be fully retrievable. The End Effector systems will be deployed on the large robotic Light Duty Utility Arm (LDUA) being developed by other portions of the OTD-DOE programs. The systems implement a multi-functional ''over the coax'' design that uses a single coaxial cable for all data and control signals over the more than 900 foot cable (or fiber optic) link

  16. Constant depression fan system a novel glovebox ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    Milliner, W.V. [AME plc., Aldermaston (United Kingdom)

    1995-02-01

    In a conventional glovebox ventilation system the depression within the glovebox under normal operation is controlled by instrumentation. In the event of a breach the pressure within the box rises to atmospheric pressure, this pressure rise is detected by instrumentation which in turn operates a quick opening damper in a high depression extract to achieve a 1 metre/sec (200 fpm) inflow through the breach, which can take up to 2 seconds to establish. This system, although widely used, suffers from two distinct drawbacks: It takes a finite time to achieve the containment velocity of 1 metre/sec. It relies upon instrumentation to achieve its objectives. A new glovebox ventilation system has been developed by AWE to overcome these drawbacks. This is the Constant Depression Fan System (CDFS) which is based on an extract fan with a flat characteristic. This achieves all the requirements for the ventilation of gloveboxes and has the advantages that: It has only one moving part - the extract fan. It requires NO INSTRUMENTATION to achieve its objectives. It achieves the containment velocity of 1 metre/sec in the shortest possible time - approximately 0.2 seconds - and tests have shown that containment is maintained under breach conditions. Thus the CDFS is SAFER, SIMPLER and MORE RELIABLE.

  17. Constant depression fan system a novel glovebox ventilation system

    International Nuclear Information System (INIS)

    Milliner, W.V.

    1995-01-01

    In a conventional glovebox ventilation system the depression within the glovebox under normal operation is controlled by instrumentation. In the event of a breach the pressure within the box rises to atmospheric pressure, this pressure rise is detected by instrumentation which in turn operates a quick opening damper in a high depression extract to achieve a 1 metre/sec (200 fpm) inflow through the breach, which can take up to 2 seconds to establish. This system, although widely used, suffers from two distinct drawbacks: It takes a finite time to achieve the containment velocity of 1 metre/sec. It relies upon instrumentation to achieve its objectives. A new glovebox ventilation system has been developed by AWE to overcome these drawbacks. This is the Constant Depression Fan System (CDFS) which is based on an extract fan with a flat characteristic. This achieves all the requirements for the ventilation of gloveboxes and has the advantages that: It has only one moving part - the extract fan. It requires NO INSTRUMENTATION to achieve its objectives. It achieves the containment velocity of 1 metre/sec in the shortest possible time - approximately 0.2 seconds - and tests have shown that containment is maintained under breach conditions. Thus the CDFS is SAFER, SIMPLER and MORE RELIABLE

  18. Measure Guideline: Selecting Ventilation Systems for Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, R. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2014-02-01

    This report, developed by Building America research team CARB, addresses adding or improving mechanical ventilation systems to existing homes. The goal of this report is to assist decision makers and contractors in making informed decisions when selecting ventilation systems for homes. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including examination of relevant codes and standards. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors.

  19. SUBSURFACE VOLATIZATION AND VENTILATION SYSTEM (SVVS) - INNOVATIVE TECHNOLOGY REPORT

    Science.gov (United States)

    This report summarizes the findings associated with a Demonstration Test of Environmental Improvement Technologies’ (EIT) Subsurface Volatilization and Ventilation System (SVVS) process. The technology was evaluated under the EPA Superfund Innovative Technology Evaluation (SITE) ...

  20. SITE TECHNOLOGY CAPSULE: SUBSURFACE VOLATILIZATION AND VENTILATION SYSTEM (SVVS)

    Science.gov (United States)

    The Subsurface Volatilization and Ventilation System is an integrated technology used for attacking all phases of volatile organic compound (VOC) contamination in soil and groundwater. The SVVS technology promotes insitu remediation of soil and groundwater contaminated with or-ga...

  1. Logistics background study: underground mining

    Energy Technology Data Exchange (ETDEWEB)

    Hanslovan, J. J.; Visovsky, R. G.

    1982-02-01

    Logistical functions that are normally associated with US underground coal mining are investigated and analyzed. These functions imply all activities and services that support the producing sections of the mine. The report provides a better understanding of how these functions impact coal production in terms of time, cost, and safety. Major underground logistics activities are analyzed and include: transportation and personnel, supplies and equipment; transportation of coal and rock; electrical distribution and communications systems; water handling; hydraulics; and ventilation systems. Recommended areas for future research are identified and prioritized.

  2. Analysis of ventilation balance of mines in the Ostrava-Karvina coal district in 1992

    Energy Technology Data Exchange (ETDEWEB)

    Brudnik, J.; Ryska, V. (Obvodni Bansky Urad, Ostrava (Czech Republic))

    1993-07-01

    Comparatively evaluates ventilation of 14 underground coal mines in the Ostrava-Karvina coal district (8 in the Karvina area and 6 in the Ostrava area). The following aspects are analyzed: number of ventilation shafts, flow rate of fresh air forced by the main blower systems, depression, efficiency, flow rate forced by exhaust ventilation blowers, their efficiency, general efficiency of the ventilation systems, pressure losses, temperature, humidity and velocity of the air used for face ventilation, types of air conditioning systems, emission of methane in the mines, use of local ventilation systems, degassing efficiency. Statistical data that characterize operation of the ventilation systems, coal seam degassing and air conditioning are analyzed.

  3. Ventilation systems and components of nuclear power plants

    International Nuclear Information System (INIS)

    1997-01-01

    The most important radiation and nuclear safety requirements for the design and manufacture of nuclear power plant ventilation systems and components are presented in the guide. Also the regulatory activities of the Finnish Centre for Radiation and Nuclear Safety (STUK) as regards the ventilation systems and components are explained. Documents and data which shall be submitted to STUK during the various phases of the regulatory procedure relating to the design, construction, commissioning and operation of the nuclear power plants are presented. (13 refs.)

  4. Rising damp in building walls: the wall base ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, A.S.; Delgado, J.M.P.Q.; Freitas, V.P. de [Faculdade de Engenharia da Universidade do Porto, Laboratorio de Fisica das Construcoes (LFC), Departamento de Engenharia Civil, Porto (Portugal)

    2012-12-15

    This work intends to validate a new system for treating rising damp in historic buildings walls. The results of laboratory experiments show that an efficient way of treating rising damp is by ventilating the wall base, using the HUMIVENT technique. The analytical model presented describes very well the observed features of rising damp in walls, verified by laboratory tests, who contributed for a simple sizing of the wall base ventilation system that will be implemented in historic buildings. (orig.)

  5. Dependence of radon level on ventilation systems in residences

    International Nuclear Information System (INIS)

    Kokotti, H.

    1995-01-01

    The concentration of indoor radon and radon entry from soil into a house are expected to increase with increasing radon concentration in soil pores, and indoor radon concentration is expected to decrease with increasing ventilation rate. Depressurization, which can be caused by the stack effect, by wind and by unbalanced ventilation, creates different pressure conditions in a house and in the soil beneath it. To reveal the possible differences in radon removal and entry resulting from different ventilation systems, radon concentrations were determined in three similar slab-on-grade buildings provided with mechanical supply and exhaust ventilation, mechanical exhaust or natural ventilation. To limitate the effect of differences in soil parameters, the houses were constructed on the same gravel esker in Kuopio. Thus, the variation in radon entry as a result of different depressurisation of the houses (caused by unbalanced mechanical ventilation systems) could also be observed. In addition, the effect of pressurisation on living rooms could be determined in five slab-on-grade houses constructed on the same esker in Hollola. Mechanical supply and exhaust ventilation system controlled by measured indoor-outdoor pressure difference, was installed in the six houses. The seasonal variation with and without controlled pressure conditions were followed in a slab-on-grade house constructed on a gravel esker in Rekola. Long-term radon concentrations were observed to correlate negatively with air exchange rates. However, the removal effect of ventilation was found to be disturbed by negative pressure due to the stack effect and/or to unbalanced mechanical ventilation. (91 refs., 17 figs., 10 tabs.)

  6. The pit ventilation features and the design principle of ventilation system in trackless mining uranium mine

    International Nuclear Information System (INIS)

    Deng Wenhui; Zhou Xinghuo; Li Xianjie

    2001-01-01

    According to the pit arrangement features of trackless mining uranium mine, based on the fundamental of radon permeation and control, and analysis of radon pollution characteristics and radon education, the design principle of ventilation system in trackless mining uranium mine has been raised

  7. Hydrogen risk analysis for a generic nuclear containment ventilation system

    International Nuclear Information System (INIS)

    Xu, Z.; Jordan, T.

    2015-01-01

    Hydrogen safety issue in a ventilation system of a generic nuclear containment is studied. In accidental scenarios, a large amount of burnable gas mixture of hydrogen with certain amount of oxygen is released into the containment. In case of high containment pressure, the combustible mixture is further ventilated into the chambers and the piping of the containment ventilation system. The burnable even potentially detonable gas mixture could pose a risk to the structures of the system once being ignited unexpectedly. Therefore the main goal of the study is to apply the computational fluid dynamics (CFD) computer code - GASFLOW, to analyze the distribution of the hydrogen in the ventilation system, and to find how sensitive the mixture is to detonation in different scenarios. The CFD simulations manifest that a ventilation fan with sustained power supply can extinguish the hydrogen risk effectively. However in case of station blackout with loss of power supply to the fan, hydrogen/oxygen mixture could be accumulated in the ventilation system. A further study proves that steam injection could degrade the sensitivity of the hydrogen mixture significantly. (author)

  8. Passive ventilation systems with heat recovery and night cooling

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2008-01-01

    of Denmark. Through building integration in high performance offices the system is optimized to incorporate multiple functions like heating, cooling and ventilation, thus saving the expenses of separate cooling and heating systems. The simulation results are derived using the state-of-the-art building......In building design the requirements for energy consumption for ventilation, heating and cooling and the requirements for increasingly better indoor climate are two opposing factors. This paper presents the schematic layout and simulation results of an innovative multifunc-tional ventilation concept...... with little energy consumption and with satisfying indoor climate. The concept is based on using passive measures like stack and wind driven ventilation, effective night cooling and low pressure loss heat recovery using two fluid coupled water-to-air heat exchangers developed at the Technical University...

  9. Magneto-Inductive Underground Communications in a District Heating System

    DEFF Research Database (Denmark)

    Meybodi, Soroush Afkhami; Nielsen, Jens Frederik Dalsgaard; Bendtsen, Jan Dimon

    2011-01-01

    Feasibility of underground data communications is investigated by employing magnetic induction as the key technology at physical layer. Realizing an underground wireless sensor network for a district heating plant motivates this research problem. The main contribution of the paper is to find the ...

  10. Informal value transfer systems and criminal organizations : A study into so-called underground banking networks

    NARCIS (Netherlands)

    Passas, N.

    1999-01-01

    This report presents the findings of a preliminary study into what is commonly called 'underground banking systems'. As the conventional banking industry is increasingly being regulated many fear that criminal organizations may turn to alternatives, such as underground banking systems - or informal

  11. Underground transportation and handling system for Pollux-casks

    International Nuclear Information System (INIS)

    Schrimpf, C.

    1988-01-01

    The concept for the underground transportation and handling system for Pollux-casks was optimized in a first phase by dividing the process in the repository up into the several transportation and manipulation steps. For each step, the possibilities were described and evaluated by means of a list of criteria (technical, safety and economical criteria). The following concept for the transportation and handling was developed: The casks are transported to the unloading area of the surface facilities by railway or truck. After removal of the transport protection, the entry control is performed. The cask is lifted from the vehicle and placed on a railbound transportation vehicle. This transport unit is transferred to the shaft and placed there ready for shaft hoisting. With the hoisting cage protruding, the transport unit is placed on the hoisting cage by means of a pushing-on device, locked, and then conveyed underground. After arrival on the emplacement level, the transport unit is pulled-off from the hoisting cage and taken over by a mine locomotive and transferred through the transportation and access drifts as far as to the emplacement site. There the locomotive pushed the rail transport vehicle into the emplacement drift, as far as to the designated emplacement position. At the emplacement position, the cask is again lifted by means of hoisting equipment. The rail transport vehicle is pulled out of the emplacement drift and returned to the surface for reloading. After deposition of the cask on the drift floor, the emplacement equipment is pulled back in order to give the operation space free for the slinger backfill truck. Within preceding tests two different backfilling techniques were investigated under realistic conditions: pneumatic backfilling and slinger backfilling. The slinger truck was found to be the most suitable for the designated purpose

  12. Decision and systems analysis for underground storage tank waste retrieval systems and tank waste remediation system

    Energy Technology Data Exchange (ETDEWEB)

    Bitz, D.A. [Independent Consultant, Kirkland, WA (United States); Berry, D.L. [Sandia National Labs., Albuquerque, NM (United States); Jardine, L.J. [Lawrence Livermore National Lab., CA (United States)

    1994-03-01

    Hanford`s underground tanks (USTs) pose one of the most challenging hazardous and radioactive waste problems for the Department of Energy (DOE). Numerous schemes have been proposed for removing the waste from the USTs, but the technology options for doing this are largely unproven. To help assess the options, an Independent Review Group (IRG) was established to conduct a broad review of retrieval systems and the tank waste remediation system. The IRG consisted of the authors of this report.

  13. Decision and systems analysis for underground storage tank waste retrieval systems and tank waste remediation system

    International Nuclear Information System (INIS)

    Bitz, D.A.; Berry, D.L.; Jardine, L.J.

    1994-03-01

    Hanford's underground tanks (USTs) pose one of the most challenging hazardous and radioactive waste problems for the Department of Energy (DOE). Numerous schemes have been proposed for removing the waste from the USTs, but the technology options for doing this are largely unproven. To help assess the options, an Independent Review Group (IRG) was established to conduct a broad review of retrieval systems and the tank waste remediation system. The IRG consisted of the authors of this report

  14. Preoperational test report, primary ventilation condenser cooling system

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents the preoperational test report for the Primary Ventilation Condenser Cooling System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system uses a closed chilled water piping loop to provide offgas effluent cooling for tanks AY101, AY102, AZ1O1, AZ102; the offgas is cooled from a nominal 100 F to 40 F. Resulting condensation removes tritiated vapor from the exhaust stack stream. The piping system includes a package outdoor air-cooled water chiller with parallel redundant circulating pumps; the condenser coil is located inside a shielded ventilation equipment cell. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  15. Optimized damper control of pressure and airflow in ventilation systems

    DEFF Research Database (Denmark)

    Koulani, Chrysanthi Sofia; Hviid, Christian Anker; Terkildsen, Søren

    2014-01-01

    Conventional control strategies in variable air volume (VAV) ventilation systems do not take fully into advantage the potential energy savings since the system operation is based on maintaining a constant static pressure (CSP) set point in the main duct irrespective of the actual pressure demand...... by using the Simulink programming tool which is addon software to MATLAB mathematical programming language. A model of a VAV ventilation system was created in Simulink based on the International Building Physics Toolbox (IBPT); the IBPT thermal zone was remodelled in order to calculate dynamically...... the airflow demand according to the zone air temperature. The performance of the Simulink model was evaluated based on the experimental setup of the ventilation system. The SPR control method established stable system operation and was proven efficient to maintain comfortable space conditions while reducing...

  16. Preoperational test report, primary ventilation condenser cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-10-29

    This represents the preoperational test report for the Primary Ventilation Condenser Cooling System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system uses a closed chilled water piping loop to provide offgas effluent cooling for tanks AY101, AY102, AZ1O1, AZ102; the offgas is cooled from a nominal 100 F to 40 F. Resulting condensation removes tritiated vapor from the exhaust stack stream. The piping system includes a package outdoor air-cooled water chiller with parallel redundant circulating pumps; the condenser coil is located inside a shielded ventilation equipment cell. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  17. Analysis of different strategies of automatic control applied to a didactic prototype for the study of underground mines ventilation

    Directory of Open Access Journals (Sweden)

    Juan Mauricio Salamanca

    2014-12-01

    Full Text Available This paper describes a prototype developed for the study and control of ventilation for mining. Modeling is presented by means of a parametric identification and the result of the application of basic control strategies such as PID, On-Off and advanced as a control based on sliding modes.

  18. Decision and systems analysis for underground storage tank waste retrieval systems and tank waste remediation system

    International Nuclear Information System (INIS)

    Berry, D.L.; Jardine, L.J.

    1993-10-01

    Hanford's underground storage tanks (USTs) pose one of the most challenging hazardous and radioactive waste problems for the Department of Energy (DOE). Numerous schemes have been proposed for removing the waste from the USTs, but the technology options for doing this are largely unproven. To help assess the options, an Independent Review Group (IRG) was established to conduct a broad review of retrieval systems and the tank waste remediation system. The IRG consisted of the authors of this report. The IRG's Preliminary Report assessed retrieval systems for underground storage tank wastes at Hanford in 1992. Westinghouse Hanford Company (WHC) concurred with the report's recommendation that a tool should be developed for evaluating retrieval concepts. The report recommended that this tool include (1) important considerations identified previously by the IRG, (2) a means of documenting important decisions concerning retrieval systems, and (3) a focus on evaluations and assessments for the Tank Waste Remediation System (TWRS) and the Underground Storage Tank-Integrated Demonstration (UST-ID)

  19. Design of energy efficient ventilation and air-conditioning systems

    CERN Document Server

    Seppänen, Olli; Bertilsson, Thore; Maripuu, Mari-Liis; Lamy, Hervé; Vanden Borre, Alex

    2012-01-01

    This guidebook covers numerous system components of ventilation and air-conditioning systems and shows how they can be improved by applying the latest technology products. Special attention is paid to details, which are often overlooked in the daily design practice, resulting in poor performance of high quality products once they are installed in the building system.

  20. Bioclimatic underground architecture: Development and principles

    OpenAIRE

    Stojić Jasmina; Stanković Danica

    2009-01-01

    The principal idea of paper lies in analyzing contemporary architectural challenges, concerning climate changes, global warming, renewable energy deficiency and population growth. The relevant examples and principles of sustainable and selfsustainable architecture development throughout history are presented. Underground structures as passive solar systems, vegetation used as insulation, ventilation and isolation are given as one of possible solutions for this global phenomenon. By studying t...

  1. Basement depressurization using dwelling mechanical exhaust ventilation system

    International Nuclear Information System (INIS)

    Collignan, B.; O'Kelly, P.; Pilch, E.

    2004-01-01

    The mechanical ventilation exhaust system is commonly used in France to generate air renewal into building and especially into dwelling. It consists of a permanent mechanical air extraction from technical rooms (kitchen, bathrooms and toilets) using a unique fan connected to exhaust ducts. Natural air inlets in living room and bed rooms ensure an air flow from living spaces towards technical rooms. To fight against radon into building, the most recognised efficient technique is the Soil Depressurization System (S.D.S.) consisting in depressurizing the house basement. The aim of this study is to test the ability of the dwelling mechanical ventilation system to depressurize the basement in conjunction with air renewal of a house. For that purpose, a S.D.S. has been installed in an experimental house at CSTB during its construction. At first, tests undertaken with a variable velocity fan connected to the S.D.S. have characterised the permeability of the basement. It is shown that basement can be depressurized adequately with a relatively low air flow rate. At a second stage, S.D.S. has been connected to the exhaust ventilation fan used for the mechanical ventilation of the house. Results obtained show the ability of such ventilation system to generate sufficient depressurization in the basement and to ensure simultaneously adequate air change rate in the dwelling. (author)

  2. Performance evaluation of the pilot-scale, double-shell tank ventilation system using simulated aerosol streams

    Energy Technology Data Exchange (ETDEWEB)

    Brouns, T.M.; Peterson, M.E.

    1989-12-01

    Radioactive waste slurries are currently being stored in underground tanks on the Hanford Site. The slurries that are being stored in the double-shell tanks (DSTs) are various mixtures of radioactive solids, liquids, and aqueous wastes. The tanks must be maintained at a negative pressure relative to atmospheric pressure to safeguard against pressurization and the subsequent leakage of entrained radioactive aerosols to the environment. A ventilation system must be capable of withdrawing the total volume of off gas generated from the tanks while maintaining the tanks at a negative pressure. Westinghouse Hanford Company (WHC) has identified a need to improve the efficiency of the ventilation system being used on the tank farms to meet the more restrictive release limits for radioactive isotopes. Kaiser Engineers Hanford Company (KEH) has been contracted by WHC to design the new ventilation system for the existing tank farms. WHC contracted the Pacific Northwest Laboratory (PNL) to fabricate and test the prototypic pilot-scale design prior to finalizing the design of the ventilation system. The PNL has conducted tests to determine (1) the effectiveness of the system for removal of vapors condensable at 35{degrees}F, (2) the effectiveness for removal of soluble and insoluble aerosols, and (3) the life span of the mist eliminators to be used in the new system. The results of extensive testing of the pilot-scale system with condensables and both soluble and insoluble aerosols are presented in this report. 7 refs., 25 figs., 8 tabs.

  3. Argonne Fuel Cycle Facility ventilation system -- modeling and results

    International Nuclear Information System (INIS)

    Mohr, D.; Feldman, E.E.; Danielson, W.F.

    1995-01-01

    This paper describes an integrated study of the Argonne-West Fuel Cycle Facility (FCF) interconnected ventilation systems during various operations. Analyses and test results include first a nominal condition reflecting balanced pressures and flows followed by several infrequent and off-normal scenarios. This effort is the first study of the FCF ventilation systems as an integrated network wherein the hydraulic effects of all major air systems have been analyzed and tested. The FCF building consists of many interconnected regions in which nuclear fuel is handled, transported and reprocessed. The ventilation systems comprise a large number of ducts, fans, dampers, and filters which together must provide clean, properly conditioned air to the worker occupied spaces of the facility while preventing the spread of airborne radioactive materials to clean am-as or the atmosphere. This objective is achieved by keeping the FCF building at a partial vacuum in which the contaminated areas are kept at lower pressures than the other worker occupied spaces. The ventilation systems of FCF and the EBR-II reactor are analyzed as an integrated totality, as demonstrated. We then developed the network model shown in Fig. 2 for the TORAC code. The scope of this study was to assess the measured results from the acceptance/flow balancing testing and to predict the effects of power failures, hatch and door openings, single-failure faulted conditions, EBR-II isolation, and other infrequent operations. The studies show that the FCF ventilation systems am very controllable and remain stable following off-normal events. In addition, the FCF ventilation system complex is essentially immune to reverse flows and spread of contamination to clean areas during normal and off-normal operation

  4. Evaluation of a computerized system for mechanical ventilation of infants.

    Science.gov (United States)

    Tehrani, Fleur T; Abbasi, Soraya

    2009-04-01

    To evaluate a computerized system for mechanical ventilation of infants. FLEX is a computerized system that includes the features of a patented mode known as adaptive-support ventilation (ASV). In addition, it has many other features including adjustment of positive end-expiratory pressure (PEEP), fraction of inspired oxygen (F(IO2)), minute ventilation, and control of weaning. It is used as an open-loop decision support system or as a closed-loop technique. Blood gas and ventilation data were collected from 12 infants in the neonatal intensive care at baseline and at the next round of evaluation. This data were input to open-loop version of FLEX. The system recommendations were compared to clinical determinations. FLEX recommended values for ventilation were on the average within 25% and 16.5% of the measured values at baseline and at the next round of evaluation, respectively. For F(IO2) and PEEP, FLEX recommended values were in general agreement with the clinical settings. FLEX recommendations for weaning were the same as the clinical determinations 50% of the time at baseline and 55% of the time at the next round of evaluation. FLEX did not recommend weaning for infants with weak spontaneous breathing effort or those who showed signs of dyspnea. A computerized system for mechanical ventilation is evaluated for treatment of infants. The results of the study show that the system has good potential for use in neonatal ventilatory care. Further refinements can be made in the system for very low-birth-weight infants.

  5. Anaesthesia ventilators

    Science.gov (United States)

    Jain, Rajnish K; Swaminathan, Srinivasan

    2013-01-01

    Anaesthesia ventilators are an integral part of all modern anaesthesia workstations. Automatic ventilators in the operating rooms, which were very simple with few modes of ventilation when introduced, have become very sophisticated with many advanced ventilation modes. Several systems of classification of anaesthesia ventilators exist based upon various parameters. Modern anaesthesia ventilators have either a double circuit, bellow design or a single circuit piston configuration. In the bellows ventilators, ascending bellows design is safer than descending bellows. Piston ventilators have the advantage of delivering accurate tidal volume. They work with electricity as their driving force and do not require a driving gas. To enable improved patient safety, several modifications were done in circle system with the different types of anaesthesia ventilators. Fresh gas decoupling is a modification done in piston ventilators and in descending bellows ventilator to reduce th incidence of ventilator induced volutrauma. In addition to the conventional volume control mode, modern anaesthesia ventilators also provide newer modes of ventilation such as synchronised intermittent mandatory ventilation, pressure-control ventilation and pressure-support ventilation (PSV). PSV mode is particularly useful for patients maintained on spontaneous respiration with laryngeal mask airway. Along with the innumerable benefits provided by these machines, there are various inherent hazards associated with the use of the ventilators in the operating room. To use these workstations safely, it is important for every Anaesthesiologist to have a basic understanding of the mechanics of these ventilators and breathing circuits. PMID:24249886

  6. Anaesthesia ventilators

    OpenAIRE

    Jain, Rajnish K; Swaminathan, Srinivasan

    2013-01-01

    Anaesthesia ventilators are an integral part of all modern anaesthesia workstations. Automatic ventilators in the operating rooms, which were very simple with few modes of ventilation when introduced, have become very sophisticated with many advanced ventilation modes. Several systems of classification of anaesthesia ventilators exist based upon various parameters. Modern anaesthesia ventilators have either a double circuit, bellow design or a single circuit piston configuration. In the bello...

  7. Overall requirements for an advanced underground coal extraction system

    Energy Technology Data Exchange (ETDEWEB)

    Goldsmith, M.; Lavin, M.L.

    1980-10-15

    This report presents overall requirements on underground mining systems suitable for coal seams exploitable in the year 2000, with particular relevance to the resources of Central Appalachia. These requirements may be summarized as follows: (1) Production Cost: demonstrate a return on incremental investment of 1.5 to 2.5 times the value required by a low-risk capital project. (2) Miner Safety: achieve at least a 50% reduction in deaths and disabling injuries per million man-hours. (3) Miner Health: meet the intent of all applicable regulations, with particular attention to coal dust, carcinogens, and mutagens; and with continued emphasis on acceptable levels of noise and vibration, lighting, humidity and temperature, and adequate work space. (4) Environmental Impact: maintain the value of mined and adjacent lands at the pre-mining value following reclamation; mitigation of off-site impacts should not cost more than the procedures used in contemporary mining. (5) Coal Conservation: the recovery of coal from the seam being mined should be at least as good as the best available contemporary technology operating in comparable conditions. No significant trade-offs between production cost and other performance indices were found.

  8. 46 CFR 105.25-7 - Ventilation systems for cargo tank or pumping system compartment.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Ventilation systems for cargo tank or pumping system... Requirements-When Cargo Tanks Are Installed Below Decks § 105.25-7 Ventilation systems for cargo tank or pumping system compartment. (a) Each compartment shall be provided with a mechanical exhaust system...

  9. Measured Air Distribution Effectiveness for Residential Mechanical Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max; Sherman, Max H.; Walker, Iain S.

    2008-05-01

    The purpose of ventilation is dilute or remove indoor contaminants that an occupant is exposed to. In a multi-zone environment such as a house, there will be different dilution rates and different source strengths in every zone. Most US homes have central HVAC systems, which tend to mix the air thus the indoor conditions between zones. Different types of ventilation systems will provide different amounts of exposure depending on the effectiveness of their air distribution systems and the location of sources and occupants. This paper will report on field measurements using a unique multi-tracer measurement system that has the capacity to measure not only the flow of outdoor air to each zone, but zone-to-zone transport. The paper will derive seven different metrics for the evaluation of air distribution. Measured data from two homes with different levels of natural infiltration will be used to evaluate these metrics for three different ASHRAE Standard 62.2 compliant ventilation systems. Such information can be used to determine the effectiveness of different systems so that appropriate adjustments can be made in residential ventilation standards such as ASHRAE Standard 62.2.

  10. Availability Analysis of the Ventilation Stack CAM Interlock System

    CERN Document Server

    Young, J

    2000-01-01

    Ventilation Stack Continuous Air Monitor (CAM) Interlock System failure modes, failure frequencies, and system availability have been evaluated for the RPP. The evaluation concludes that CAM availability is as high as assumed in the safety analysis and that the current routine system surveillance is adequate to maintain this availability credited in the safety analysis, nor is such an arrangement predicted to significantly improve system availability.

  11. Field study of earth tempered swine ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Goetsch, W.D.; Peterson, W.H.; Muehling, A.J.

    1981-01-01

    Four earth-tube heat exchanger systems for heating and cooling the ventilation air for swine farrowing and nursery buildings were studied. Results show appreciable winter heating and summer cooling from the earth tubes with minimal variation in the temperature of the discharge air. 5 refs.

  12. DEMONSTRATION BULLETIN: SUBSURFACE VOLATILIZATION AND VENTILATION SYSTEM - BROWN & ROOT ENVIRONMENTAL

    Science.gov (United States)

    The Subsurface Volatilization and Ventilation System (SVVS*) is an in-situ vacuum extraction/air sparging and bioremediation technology for the treatment of subsurface organic contamination in soil and groundwater. The technology, developed by Billings and Associates, Inc., and o...

  13. Interaction of Air Flow in Complex Ventilation Systems

    Directory of Open Access Journals (Sweden)

    Zhorzh G. Levitskiy

    2013-01-01

    Full Text Available The article presents the results of study of interaction of air flow in complex ventilation systems. The study used Taylor and Maclaurin’s series and Lagrange formula to create the functional connections on estimation of the impact of changing aerodynamic parameters of one or several simultaneously working regulators on the air flow distribution in mines

  14. Early detection of spontaneous combustion of coal in underground coal mines with development of an ethylene enriching system

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Jun; Xue, Sheng [CSIRO Earth Science and Resource Engineering, Kenmore (Australia); Cheng, Weimin; Wang, Gang [Shandong University of Science and Technology, Qingdao (China)

    2011-01-01

    Spontaneous combustion of coal (sponcom) is a major hazard in underground coal mining operations. If not detected early and managed properly, it can seriously affect mine safety and productivity. Gaseous products of sponcom, such as carbon monoxide, ethylene and hydrogen, are commonly used in coal mines as indicators to reflect the state of the sponcom. Studies have shown that ethylene starts to occur when sponcom reaches a characteristic temperature. However, due to dilution of ventilation air and detection limits of the instruments used for gas analysis at coal mines, ethylene cannot be detected until the sponcom has developed past its early stage, missing an optimum opportunity for mine operators to control the hazard. To address the issue, an ethylene-enriching system, based on its physical adsorption and desorption properties, has been developed to increase detection sensitivity of the ethylene concentration in mine air by about 10 times. This system has successfully been applied in a number of underground coal mines in China to detect sponcom at its early stage and enable mine operators to take effective control measures. This paper describes the ethylene enriching system and its application. (author)

  15. Heating, Ventilation and Air-Conditioning Systems, Part of Indoor Air Quality Design Tools for Schools

    Science.gov (United States)

    The main purposes of a Heating, Ventilation, and Air-Conditioning system are to help maintain good indoor air quality through adequate ventilation with filtration and provide thermal comfort. HVAC systems are among the largest energy consumers in schools.

  16. Technology Solutions Case Study: Selecting Ventilation Systems for Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-12-01

    In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the "fresh" air is coming from is gaining significance as air-tightness standards for enclosures become more stringent, and the normal leakage paths through the building envelope disappear. Researchers from the Consortium for Advanced Residential Buildings (CARB) found that the majority of high performance, new construction, multifamily housing in the Northeast use one of four general strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. Insufficient information is available to designers on how these various systems are best applied. In this project, the CARB team evaluated the four different strategies for providing make-up air to multifamily residential buildings and developed guidelines to help contractors and building owners choose the best ventilation systems.

  17. Radon levels survey in the underground transport metro system in Mexico City

    International Nuclear Information System (INIS)

    Espinosa, G.

    1995-01-01

    The Metro underground transport system moves more than 8 million people daily across Mexico city. The average time a traveller remains inside the underground stations and tunnels is more than two hours. The airborne radon levels were measured, during the three months of summer, at 20 different stations, including the more deeply located halls. Stations were in different zones of the city. The radon concentration in underground corridors and stations varied from 60 Bq.m -3 to 350Bq.m 3 . The environmental factors, such as outside temperature, humidity, and days of rain were compiled in order to understand radon entry and transport better. (author)

  18. Method to assess the performance of domestic ventilation systems considering the influence of uncertainties

    NARCIS (Netherlands)

    Yang, Z.

    2012-01-01

    The ventilation system plays an important role in the indoor environment of a domestic building. A ventilation system is normally designed based on the national or regional regulations. Although ventilation systems are designed based on the same design rules, performance deviations between different

  19. Exhaust, Dust Collection and Ventilation Systems. Module SH-44. Safety and Health.

    Science.gov (United States)

    Center for Occupational Research and Development, Inc., Waco, TX.

    This student module on exhaust, dust collection, and ventilation systems is one of 50 modules concerned with job safety and health. This module discusses the types of contaminants that can be controlled by ventilation, the types of ventilation systems, and the component parts of local exhaust systems. Following the introduction, 10 objectives…

  20. CLASSIFICATION OF THE MGR WASTE TREATMENT BUILDING VENTILATION SYSTEM

    International Nuclear Information System (INIS)

    S.E. Salzman

    1999-01-01

    The purpose of this analysis is to document the Quality Assurance (QA) classification of the Monitored Geologic Repository (MGR) waste treatment building ventilation system structures, systems and components (SSCs) performed by the MGR Safety Assurance Department. This analysis also provides the basis for revision of YMP/90-55Q, Q-List (YMP 1998). The Q-List identifies those MGR SSCs subject to the requirements of DOE/RW-0333P, ''Quality Assurance Requirements and Description'' (QARD) (DOE 1998)

  1. Bilevel vs ICU ventilators providing noninvasive ventilation: effect of system leaks: a COPD lung model comparison.

    Science.gov (United States)

    Ferreira, Juliana C; Chipman, Daniel W; Hill, Nicholas S; Kacmarek, Robert M

    2009-08-01

    Noninvasive positive-pressure ventilation (NPPV) modes are currently available on bilevel and ICU ventilators. However, little data comparing the performance of the NPPV modes on these ventilators are available. In an experimental bench study, the ability of nine ICU ventilators to function in the presence of leaks was compared with a bilevel ventilator using the IngMar ASL5000 lung simulator (IngMar Medical; Pittsburgh, PA) set at a compliance of 60 mL/cm H(2)O, an inspiratory resistance of 10 cm H(2)O/L/s, an expiratory resistance of 20 cm H(2)O/ L/s, and a respiratory rate of 15 breaths/min. All of the ventilators were set at 12 cm H(2)O pressure support and 5 cm H(2)O positive end-expiratory pressure. The data were collected at baseline and at three customized leaks. At baseline, all of the ventilators were able to deliver adequate tidal volumes, to maintain airway pressure, and to synchronize with the simulator, without missed efforts or auto-triggering. As the leak was increased, all of the ventilators (except the Vision [Respironics; Murrysville, PA] and Servo I [Maquet; Solna, Sweden]) needed adjustment of sensitivity or cycling criteria to maintain adequate ventilation, and some transitioned to backup ventilation. Significant differences in triggering and cycling were observed between the Servo I and the Vision ventilators. The Vision and Servo I were the only ventilators that required no adjustments as they adapted to increasing leaks. There were differences in performance between these two ventilators, although the clinical significance of these differences is unclear. Clinicians should be aware that in the presence of leaks, most ICU ventilators require adjustments to maintain an adequate tidal volume.

  2. BBUNS: Bluetooth Beacon-Based Underground Navigation System to Support Mine Haulage Operations

    Directory of Open Access Journals (Sweden)

    Jieun Baek

    2017-11-01

    Full Text Available A Bluetooth beacon-based underground navigation system (BBUNS was developed to identify the optimal haul road in an underground mine, track the locations of dump trucks, and display this information on mobile devices. A three-dimensional (3-D geographic information system (GIS database of the haul roads in an underground mine was constructed, and the travel time for each section was calculated. A GIS database was also constructed for 50 Bluetooth beacons that were installed along the haul roads. An Android-based BBUNS application was developed to visualize the current location of each dump truck and the optimal haul road to the destination on mobile devices, using the Bluetooth beacon system that was installed in the underground mine. Whenever the BBUNS recognized all of the Bluetooth beacons installed in the underground mine, it could provide the dump truck drivers with information on the current location and the two-dimensional (2-D and 3-D haul road properties. The operating time of each dump truck and the time spent on each unit task could be analyzed using recorded data on the times when Bluetooth beacon signals were recognized by the BBUNS. The underground mine navigation system that was developed in this study can contribute to the improvement of haul operation efficiency and productivity.

  3. Exposure of ventilation system cleaning workers to harmful microbiological agents.

    Science.gov (United States)

    Gołofit-Szymczak, Małgorzata; Ławniczek-Wałczyk, Anna; Górny, Rafał L

    2013-01-01

    Regular inspection of the cleanliness of the ventilation systems, as well as their periodic cleaning and disinfection, if necessary, are the main factors of the proper maintenance of each system. Performing maintenance operations on the ventilation system, workers are exposed to risk associated with the exposure to harmful biological agents. The aim of this study was to assess the employees' exposure to bioaerosols during maintenance work on ventilation systems. Bioaerosol measurements were carried out using a button sampler. The microbial particles were collected on gelatin filters. Settled-dust samples from the inner surface of the air ducts and filter-mat samples were selected for the microbiological analysis. In the collected air, dust and filter samples the concentration of bacteria and fungi were determined. Bacteria and fungi concentrations ranged between 3.6 x 10(2)-2.2 x 10(4) CFU/m3 and 4.7 x 10(2)-4.5 x 10(3) CFU/m3 at workplaces where the operations connected with mechanical ventilation cleaning were performed and 2.2 x 10(4)-1.2 x 10(5) CFU/m2 and 9.8 x 10(1)-2.5 x 10(2) CFU/m3 at workplaces where filter exchange was performed, respectively. The qualitative analysis of microorganisms isolated from the air in all studied workplaces revealed that the most prevalent bacteria belonged to Bacillus genus. The average concentrations of bacteria and fungi in filter-mat samples were 3.3 x 10(3) CFU/cm2 and 1.4 x 10(4) CFU/cm2, respectively. In settled-dust samples, average concentrations were 591 CFU/100 cm2 and 52 CFU/100 cm2, for bacteria and fungi respectively. Workers cleaning ventilation systems are exposed to harmful biological agents classified into risk groups, 1 and 2, according to their level of the risk of infection. The research conducted in the workplace can be the basis of risk assessment related to exposure to harmful biological agents during maintenance work in ventilation.

  4. Third symposium on underground mining

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-01-01

    The Third Symposium on Underground Mining was held at the Kentucky Fair and Exposition Center, Louisville, KY, October 18--20, 1977. Thirty-one papers have been entered individually into EDB and ERA. The topics covered include mining system (longwall, shortwall, room and pillar, etc.), mining equipment (continuous miners, longwall equipment, supports, roof bolters, shaft excavation equipment, monitoring and control systems. Maintenance and rebuilding facilities, lighting systems, etc.), ventilation, noise abatement, economics, accidents (cost), dust control and on-line computer systems. (LTN)

  5. Design of multifunctional temperature controller for NPP ventilation system

    International Nuclear Information System (INIS)

    Xiao Xipeng; He Li; Yin Xiaolong; Gong Jianjun

    2014-01-01

    Based on full study on the original analog temperature controller of ventilation system in nuclear power plant, for the interface definition fixation, parameters preset as well as multiple output combination of the temperature controller circuit, a digital temperature circuit based on the front-end input conditioning module + multi channel ADC+STM32 architecture is proposed. The hardware structure and software process are described in details. The sampling data processing, phase-cut voltage output as well as control principle are focused, and some part of software program is presented. The experimental results show that the temperature controller can stably and reliably control the temperature of ventilation system and display digital parameters, and it can completely replace and upgrade the original analog controller. (authors)

  6. Evaluating Ventilation Systems for Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, R.; Arena, L.

    2013-02-01

    During the course of this project, an affordable and high performance ductwork system to directly address the problems of thermal losses, poor efficiency, and air leakage was designed. To save space and enable direct connections between different floors of the building, the ductwork system was designed in such a way that it occupied interior or exterior frame wall cavities. The ductwork system satisfied building regulations for structural support when bridging multiple floors, the spread of fire and smoke, and insulation to reduce the heat flow into or out of the building. Retrofits of urban residential buildings will be the main focus for the application of this ductwork system. Highly reflective foils and insulating materials were used to aid in the increase of the overall R-value of the ductwork itself and the wall assembly. It is expected that the proposed system will increase the efficiency of the HVAC system and the thermal resistance of the building envelope. The performance of the proposed ductwork design was numerically evaluated in a number of different ways. Our results indicate that the duct method is a very cost attractive alternative to the conventional method.

  7. Numerical simulation of volume-controlled mechanical ventilated respiratory system with 2 different lungs.

    Science.gov (United States)

    Shi, Yan; Zhang, Bolun; Cai, Maolin; Zhang, Xiaohua Douglas

    2017-09-01

    Mechanical ventilation is a key therapy for patients who cannot breathe adequately by themselves, and dynamics of mechanical ventilation system is of great significance for life support of patients. Recently, models of mechanical ventilated respiratory system with 1 lung are used to simulate the respiratory system of patients. However, humans have 2 lungs. When the respiratory characteristics of 2 lungs are different, a single-lung model cannot reflect real respiratory system. In this paper, to illustrate dynamic characteristics of mechanical ventilated respiratory system with 2 different lungs, we propose a mathematical model of mechanical ventilated respiratory system with 2 different lungs and conduct experiments to verify the model. Furthermore, we study the dynamics of mechanical ventilated respiratory system with 2 different lungs. This research study can be used for improving the efficiency and safety of volume-controlled mechanical ventilation system. Copyright © 2016 John Wiley & Sons, Ltd.

  8. Indoor Chemistry: Materials, Ventilation Systems, and Occupant Activities

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, G.C.; Corsi, R.L.; Destaillats, H.; Nazaroff, W.W.; Wells, J.R.

    2006-05-01

    Chemical processes taking place in indoor environments can significantly alter the nature and concentrations of pollutants. Exposure to secondary contaminants generated in these reactions needs to be evaluated in association with many aspects of buildings to minimize their impact on occupant health and well-being. Focusing on indoor ozone chemistry, we describe alternatives for improving indoor air quality by controlling chemical changes related to building materials, ventilation systems, and occupant activities.

  9. Stochastic Prediction of Ventilation System Performance

    DEFF Research Database (Denmark)

    Haghighat, F.; Brohus, Henrik; Frier, Christian

    The paper briefly reviews the existing techniques for predicting the airflow rate due to the random nature of forcing functions, e.g. wind speed. The effort is to establish the relationship between the statistics of the output of a system and the statistics of the random input variables and param......The paper briefly reviews the existing techniques for predicting the airflow rate due to the random nature of forcing functions, e.g. wind speed. The effort is to establish the relationship between the statistics of the output of a system and the statistics of the random input variables...

  10. Accident Prevention and Diagnostics of Underground Pipeline Systems

    Science.gov (United States)

    Trokhimchuk, M.; Bakhracheva, Y.

    2017-11-01

    Up to forty thousand accidents occur annually with underground pipelines due to corrosion. The comparison of the methods for assessing the quality of anti-corrosion coating is provided. It is proposed to use the device to be tied-in to existing pipeline which has a higher functionality in comparison with other types of the devices due to the possibility of tie-in to the pipelines with different diameters. The existing technologies and applied materials allow us to organize industrial production of the proposed device.

  11. [Effect of underground work on cardiovascular system 
in coal miners].

    Science.gov (United States)

    Lai, Zhiwei; Wang, Xiaoye; Tan, Hongzhuan; Huang, Yaoyu; Lu, Changcheng

    2015-10-01

    To study the effect of underground work on cardiovascular system health in coal miners.
 Male coal miners, who received electrocardiographic examinations between June, 2013 and August, 2014 in Hunan Prevention and Treatment Institute for Occupational Diseases to exclude pneumoconiosis, were enrolled for this study (n=3 134). Miners with 2 years or more underground work experience were selected as the exposed group (n=2 370), while miners without underground work experience were selected as the control group (n=764). The prevalence of electrocardiographic abnormalities and the influential factors were compared between the 2 groups.
 The prevalences of electrocardiographic abnormalities, hypertension, heart rate abnormalities and cardiovascular system abnormalities in the exposed group vs the control group were 37.6% vs 25.4%, 20.5% vs 13.4%, 5.7% vs 6.0%, 49.8% vs 35.2%, respectively. The cardiovascular system abnormalities were correlated with the underground work (OR=3.128, 95% CI: 1.969-4.970), the underground work experience (OR=1.205, 95% CI: 1.070-1.358) and the type of works (mining worker OR=1.820, 95% CI: 1.527-2.169; auxiliary worker OR=1.937, 95% CI: 1.511-2.482; other worker OR=3.291, 95%CI: 2.120-5.109).
 Underground work may increase the prevalence of cardiovascular system abnormalities for coal miners. The longer the coal miners work in underground, the higher the risk of the cardiovascular system abnormalities they are.

  12. Experimental Study of Air Distribution and Ventilation Effectiveness in a Room with a Combination of Different Mechanical Ventilation and Heating/Cooling Systems

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.; Simone, Angela; Krajcik, Michal

    2011-01-01

    Mixing and displacement ventilation are common systems in commercial buildings, while mixing ventilation is used in residential buildings. Displacement ventilation provides fresh air to the occupied zone in a more efficient way than mixing ventilation but it is important to know how well it works...... with a floor system for heating or cooling. Can, for example, a floor heating system warm up the supply air too fast and destroy the displacement effect? Will floor cooling, combined with displacement ventilation, result in too high a vertical temperature difference and too low a temperature at feet level......? The required amount of ventilation depends on the ventilation effectiveness. In standards, the recommended values for ventilation effectiveness depend on the position of the supply and exhaust device and on the difference between supply and room air temperature. Among others, for warm air heating...

  13. Modeling and Control of Livestock Ventilation Systems and Indoor Environments

    DEFF Research Database (Denmark)

    Wu, Zhuang; Heiselberg, Per; Stoustrup, Jakob

    2005-01-01

    and indoor environments with a major emphasis on the prediction of indoor horizontal variation of temperature and concentration adapted to the design of appropriate controlling strategy and control systems. The Linear Quadratic (LQ) optimal control method taking into account of the effect of necessary...... constraints and random disturbances is designed through system linearization. The well designed control systems are able to determine the demand ventilation rate and airflow pattern, improve and optimize the indoor Thermal Comfort (TC), Indoor Air Quality (IAQ) and energy use....

  14. Improving the effectiveness of boiler units with coal dust systems equipped with mill-ventilators

    Science.gov (United States)

    Elsukov, V. K.

    2007-09-01

    Problems pertinent to controlling the load of steam boilers and coal dust systems equipped with mill-ventilators are analyzed. A comprehensive set of patented technical solutions for these problems is presented. A formula for determining the ventilation output of mill-ventilators as a function of the fuel charge is proposed.

  15. Analysis of radon reduction and ventilation systems in uranium mines in China

    International Nuclear Information System (INIS)

    Hu Penghua; Li Xianjie

    2012-01-01

    Mine ventilation is the most important way of reducing radon in uranium mines. At present, the radon and radon progeny levels in Chinese uranium mines where the cut and fill stoping method is used are 3–5 times higher than those in foreign uranium mines, as there is not much difference in the investments for ventilation protection between Chinese uranium mines and international advanced uranium mines with compaction methodology. In this paper, through the analysis of radon reduction and ventilation systems in Chinese uranium mines and the comparison of advantages and disadvantages between a variety of ventilation systems in terms of radon control, the authors try to illustrate the reasons for the higher radon and radon progeny levels in Chinese uranium mines and put forward some problems in three areas, namely the theory of radon control and ventilation systems, radon reduction ventilation measures and ventilation management. For these problems, this paper puts forward some proposals regarding some aspects, such as strengthening scrutiny, verifying and monitoring the practical situation, making clear ventilation plans, strictly following the mining sequence, promoting training of ventilation staff, enhancing ventilation system management, developing radon reduction ventilation technology, purchasing ventilation equipment as soon as possible in the future, and so on.

  16. Analysis of radon reduction and ventilation systems in uranium mines in China.

    Science.gov (United States)

    Hu, Peng-hua; Li, Xian-jie

    2012-09-01

    Mine ventilation is the most important way of reducing radon in uranium mines. At present, the radon and radon progeny levels in Chinese uranium mines where the cut and fill stoping method is used are 3-5 times higher than those in foreign uranium mines, as there is not much difference in the investments for ventilation protection between Chinese uranium mines and international advanced uranium mines with compaction methodology. In this paper, through the analysis of radon reduction and ventilation systems in Chinese uranium mines and the comparison of advantages and disadvantages between a variety of ventilation systems in terms of radon control, the authors try to illustrate the reasons for the higher radon and radon progeny levels in Chinese uranium mines and put forward some problems in three areas, namely the theory of radon control and ventilation systems, radon reduction ventilation measures and ventilation management. For these problems, this paper puts forward some proposals regarding some aspects, such as strengthening scrutiny, verifying and monitoring the practical situation, making clear ventilation plans, strictly following the mining sequence, promoting training of ventilation staff, enhancing ventilation system management, developing radon reduction ventilation technology, purchasing ventilation equipment as soon as possible in the future, and so on.

  17. Controlled ventilation with the Mapleson D system A theoretical and experimental study.

    Science.gov (United States)

    Seeley, H F; Barnes, P K; Conway, C M

    1977-02-01

    A theoretical analysis has been performed to show the interrelationships between alveolar carbon dioxide concentration, carbon dioxide output, alveolar ventilation and fresh gas flow during controlled ventilation with the Mapleson D system. The model and forms of equation used have been substantiated by experiments in which dogs were ventilated through a coaxial version of the Mapleson D system at varying levels of fresh gas flow and alveolar ventilation. By assuming that man ventilated with this system behaves as does the dog, a nomogram has been produced to predict alveolar carbon dioxide concentrations at any levels of fresh gas flow and minute volume.

  18. Development of mechanical ventilation system with low energy consumption for renovation of buildings

    DEFF Research Database (Denmark)

    Terkildsen, Søren

    the performance of mechanical ventilation systems. The power consumption of mechanical ventilation depends on the flow rate, fan efficiency and pressure loss in the system. This thesis examines the options and develops a concept and components for the design of low-pressure mechanical ventilation. The hypothesis...... is that A new type of low-pressure mechanical ventilation with improved indoor environment and energy performance can be developed, by optimizing and redesigning each constituent element of conventional mechanical ventilation systems with respect to pressure and the development of new low-pressure components...... parts of a mechanical ventilation system and the parts that are critical for the hypothesis were identified. The system proposed consists of electrostatic precipitators for filtration, an “oversized” heat exchanger to reduce pressure loss and improve heat recovery efficiency, diffuse ceiling ventilation...

  19. A new positive pressure ventilation delivery system: its impact on lung ventilation studies that are technically inadequate or non diagnostic

    International Nuclear Information System (INIS)

    Bui, C.; Leiper, C.; Lee, K.; Saunders, C.; Dixson, H.; Elison, B.; Bennett, G.; Gibian, T.; Rutland, J.; Tse, V.; Elzein, H.; Babicheva, R.

    2000-01-01

    Full text: The objective of this study was to evaluate the efficacy and safety of an improved Positive Pressure Ventilation Delivery System (PVDS) in the investigation of Pulmonary Embolism (PE). The major component of PVDS is a commercially available, self-inflating 1.6L Hudson Resuscitator Bag, filled with either oxygen or air (if the patient has CO 2 retention), which is squeezed by the operator to push Technegas from the Technegas Generator Chamber to the patient via the Patient Administration Set synchronously with patient inspiration. 27 spontaneously breathing in-patients (12 males, 15 females, age range 64-89, 21 with chronic airflow limitation), whose conventional lung ventilation images were technically inadequate or non diagnostic, were re-scanned using PVDS within four days after the conventional ventilation study. Randomised blinded visual interpretation of conventional ventilation/perfusion scan vs. PVDS-assisted ventilation/perfusion scan was performed by consensus reading with two experienced observers. In conclusion PVDS was safe and well tolerated. PVDS improved the image quality of the lung ventilation scans in this cohort of patients. This technique has the potential to improve the accuracy of lung scanning in patients with severe lung disease. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  20. A Fiber Bragg Grating-Based Monitoring System for Roof Safety Control in Underground Coal Mining

    Science.gov (United States)

    Zhao, Yiming; Zhang, Nong; Si, Guangyao

    2016-01-01

    Monitoring of roof activity is a primary measure adopted in the prevention of roof collapse accidents and functions to optimize and support the design of roadways in underground coalmines. However, traditional monitoring measures, such as using mechanical extensometers or electronic gauges, either require arduous underground labor or cannot function properly in the harsh underground environment. Therefore, in this paper, in order to break through this technological barrier, a novel monitoring system for roof safety control in underground coal mining, using fiber Bragg grating (FBG) material as a perceived element and transmission medium, has been developed. Compared with traditional monitoring equipment, the developed, novel monitoring system has the advantages of providing accurate, reliable, and continuous online monitoring of roof activities in underground coal mining. This is expected to further enable the prevention of catastrophic roof collapse accidents. The system has been successfully implemented at a deep hazardous roadway in Zhuji Coal Mine, China. Monitoring results from the study site have demonstrated the advantages of FBG-based sensors over traditional monitoring approaches. The dynamic impacts of progressive face advance on roof displacement and stress have been accurately captured by the novel roadway roof activity and safety monitoring system, which provided essential references for roadway support and design of the mine. PMID:27775657

  1. A Fiber Bragg Grating-Based Monitoring System for Roof Safety Control in Underground Coal Mining

    Directory of Open Access Journals (Sweden)

    Yiming Zhao

    2016-10-01

    Full Text Available Monitoring of roof activity is a primary measure adopted in the prevention of roof collapse accidents and functions to optimize and support the design of roadways in underground coalmines. However, traditional monitoring measures, such as using mechanical extensometers or electronic gauges, either require arduous underground labor or cannot function properly in the harsh underground environment. Therefore, in this paper, in order to break through this technological barrier, a novel monitoring system for roof safety control in underground coal mining, using fiber Bragg grating (FBG material as a perceived element and transmission medium, has been developed. Compared with traditional monitoring equipment, the developed, novel monitoring system has the advantages of providing accurate, reliable, and continuous online monitoring of roof activities in underground coal mining. This is expected to further enable the prevention of catastrophic roof collapse accidents. The system has been successfully implemented at a deep hazardous roadway in Zhuji Coal Mine, China. Monitoring results from the study site have demonstrated the advantages of FBG-based sensors over traditional monitoring approaches. The dynamic impacts of progressive face advance on roof displacement and stress have been accurately captured by the novel roadway roof activity and safety monitoring system, which provided essential references for roadway support and design of the mine.

  2. A Fiber Bragg Grating-Based Monitoring System for Roof Safety Control in Underground Coal Mining.

    Science.gov (United States)

    Zhao, Yiming; Zhang, Nong; Si, Guangyao

    2016-10-21

    Monitoring of roof activity is a primary measure adopted in the prevention of roof collapse accidents and functions to optimize and support the design of roadways in underground coalmines. However, traditional monitoring measures, such as using mechanical extensometers or electronic gauges, either require arduous underground labor or cannot function properly in the harsh underground environment. Therefore, in this paper, in order to break through this technological barrier, a novel monitoring system for roof safety control in underground coal mining, using fiber Bragg grating (FBG) material as a perceived element and transmission medium, has been developed. Compared with traditional monitoring equipment, the developed, novel monitoring system has the advantages of providing accurate, reliable, and continuous online monitoring of roof activities in underground coal mining. This is expected to further enable the prevention of catastrophic roof collapse accidents. The system has been successfully implemented at a deep hazardous roadway in Zhuji Coal Mine, China. Monitoring results from the study site have demonstrated the advantages of FBG-based sensors over traditional monitoring approaches. The dynamic impacts of progressive face advance on roof displacement and stress have been accurately captured by the novel roadway roof activity and safety monitoring system, which provided essential references for roadway support and design of the mine.

  3. Energy requirements of a multi-sensor based demand control ventilation system in residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Chul Seong, Nam; Min Hong, Sung; Won Yoon, Dong [Kyoungwon University, Seoul (Korea, Republic of); Jun Moon, Hyeun [Dankook University, Yongin (Korea, Republic of); Augenbroe, Godfried [Georgia Institute of Technology, Atlanta (United States)

    2010-07-01

    Nowadays, people spend most of their time indoors. Therefore indoor air quality is of high importance and the building regulation in Korea was revised to apply 0.7 air change rate in residential apartment housing. However residents do not often operate mechanical ventilation systems mainly due to their utility cost. The aim of this paper is to present a demand control ventilation (DCV) system which implements ventilation strategies to meet the ventilation requirements. An evaluation was conducted on both conventional ventilation and sensor based DCV systems to compare their energy requirements. The study showed that the use of the DCV system results in a better indoor air quality and a lower energy consumption than conventional ventilation. This paper highlighted that the Korean ventilation regulation is not enough to control the CO2 concentration and that the use of the sensor-based DCV would result in a healthier and more comfortable indoor environment.

  4. Robotic system for remote inspection of underground storage tanks

    International Nuclear Information System (INIS)

    Griebenow, B.L.; Martinson, L.M.

    1990-01-01

    Westinghouse Idaho Nuclear Company, Inc. (WINCO), operates the Idaho Chemical Processing Plant (ICPP) for the US Department of Energy (DOE). WINCO's mission is to process government owned spent nuclear fuel. The process involves dissolving the fuel and extracting off uranium. The waste from this process is temporarily stored at the ICPP in underground storage tanks. The tanks were put in service between 1953 and 1966 and are operating 10 to 15 years beyond their design life. Five of the tanks will be replaced by 1998. The integrity of the remaining six tanks must be verified to continue their use until they can be replaced at a later data. In order to verify the tank integrity, a complete corrosion analysis must be performed. This analysis will require a remote visual inspection of the tank surfaces

  5. Ventilation models

    Science.gov (United States)

    Skaaret, Eimund

    Calculation procedures, used in the design of ventilating systems, which are especially suited for displacement ventilation in addition to linking it to mixing ventilation, are addressed. The two zone flow model is considered and the steady state and transient solutions are addressed. Different methods of supplying air are discussed, and different types of air flow are considered: piston flow, plane flow and radial flow. An evaluation model for ventilation systems is presented.

  6. DETERMINATION OF THE ZONE ENDANGERED BY METHANE EXPLOSION IN GOAF WITH CAVING OF LONGWALLS VENTILATED ON „Y” SYSTEM

    Directory of Open Access Journals (Sweden)

    Jarosław BRODNY

    2016-10-01

    Full Text Available One of the most dangerous and most commonly present risks in hard coal mines is methane hazard. During exploitation by longwall system with caving, methane is emitted to mine heading from the mined coal and coal left in a pile. A large amount of methane also flows from neighboring seams through cracks and fissures formed in rock mass. In a case of accumulation of explosive methane concentration in goaf zone and with appropriate oxygen concentration and occur-rence of initials (e.g. spark or endogenous fire, it may come to the explosion of this gas. In the paper there are present-ed results of numerical analysis of mixture of air and methane streams flow through the real heading system of a mine, characterized by high methane hazard. The aim of the studies was to analyze the ventilation system of considered head-ing system and determination of braking zones in goaf zone, in which dangerous and explosive concertation of methane can occur with sufficient oxygen concentration equal to at least 12%. Determination of position of these zones is neces-sary for the selection of appropriate parameters of the ventilation system to ensure safety of the crew. Analysis of the scale of methane hazard allows to select such a ventilation system of exploitation and neighboring headings that ensures chemical composition of mining atmosphere required by regulation, and required efficiency of methane drainage. The obtained results clearly show that numerical methods, combined with the results of tests in real conditions can be suc-cessfully used for the analysis of variants of processes related to ventilation of underground mining, and also in the anal-ysis of emergency states.

  7. Ventilation System Type and the Resulting Classroom Temperature and Air Quality During Heating Season

    DEFF Research Database (Denmark)

    Gao, Jie; Wargocki, Pawel; Wang, Yi

    2014-01-01

    The present study investigated how different ventilation system types influence classroom temperature and air quality. Five classrooms were selected in the same school. They were ventilated by manually operable windows, manually operable windows with exhaust fan, automatically operable windows...... with and without exhaust fan and by mechanical ventilation system. Temperature, relative humidity, carbon dioxide (CO2) concentration and opening of windows were continuously monitored for one month during heating season in 2012. Classroom with manually operable windows had the highest carbon dioxide concentration...... levels so that the estimated ventilation rate was the lowest compared with the classrooms ventilated with other systems. Temperatures were slightly lower in classroom ventilated by manually operable windows with exhaust fan. Windows were opened seldom even in the classroom ventilated by manually operable...

  8. Technology Solutions Case Study: Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    Energy Technology Data Exchange (ETDEWEB)

    A. Rudd and D. Bergey

    2015-08-01

    Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs.

  9. Conceptual designs of automated systems for underground emplacement and retrieval of nuclear waste

    International Nuclear Information System (INIS)

    Slocum, A.H.; Hou, W.M.; Park, K.; Hochmuth, C.; Thurston, D.C.

    1987-01-01

    Current designs of underground nuclear waste repositories have not adequately addressed the possibility of automated, unmanned emplacement and retrieval. This report will present design methodologies for development of an automated system for underground emplacement of nuclear waste. By scaling generic issues to different repositories, it is shown that a two vehicle automated waste emplacement/retrieval system can be designed to operate in a fail-safe mode. Evaluation of cost at this time is not possible. Significant gains in worker safety, however, can be realized by minimizing the possibility of human exposure

  10. Research on hydraulic system of KZC-5 type rear dump truck in underground mine

    International Nuclear Information System (INIS)

    Lei Zeyong

    2005-01-01

    KZC-5 type rear dump truck in underground mine is introduced in this paper. The determining principles and ways of two main hydraulic systems are discussed. It has been proved that the hydraulic systems are reasonable in the industrial scale test. (author)

  11. 76 FR 54163 - Proximity Detection Systems for Continuous Mining Machines in Underground Coal Mines

    Science.gov (United States)

    2011-08-31

    ... using the proximity detection system on remote controlled continuous mining machines, shuttle cars, roof.... Another commenter stated that most machines will be retrofitted with proximity detection systems in a shop... introduced a new initiative titled ``Safety Practices Around Shuttle Cars and Scoops in Underground Coal...

  12. Pressure dynamic characteristics of pressure controlled ventilation system of a lung simulator.

    Science.gov (United States)

    Shi, Yan; Ren, Shuai; Cai, Maolin; Xu, Weiqing; Deng, Qiyou

    2014-01-01

    Mechanical ventilation is an important life support treatment of critically ill patients, and air pressure dynamics of human lung affect ventilation treatment effects. In this paper, in order to obtain the influences of seven key parameters of mechanical ventilation system on the pressure dynamics of human lung, firstly, mechanical ventilation system was considered as a pure pneumatic system, and then its mathematical model was set up. Furthermore, to verify the mathematical model, a prototype mechanical ventilation system of a lung simulator was proposed for experimental study. Last, simulation and experimental studies on the air flow dynamic of the mechanical ventilation system were done, and then the pressure dynamic characteristics of the mechanical system were obtained. The study can be referred to in the pulmonary diagnostics, treatment, and design of various medical devices or diagnostic systems.

  13. Availability Analysis of the Ventilation Stack CAM Interlock System

    International Nuclear Information System (INIS)

    YOUNG, J.

    2000-01-01

    Ventilation Stack Continuous Air Monitor (CAM) Interlock System failure modes, failure frequencies and system availability have been evaluated for the RPP. The evaluation concludes that CAM availability is as high as assumed in the safety analysis and that the current routine system surveillance is adequate to maintain this availability. Further, requiring an alarm to actuate upon CAM failure is not necessary to maintain the availability credited in the safety analysis, nor is such an arrangement predicted to significantly improve system availability. However, if CAM failures were only detected by the 92-day functional tests required in the Authorization Basis (AB), CAM availability would be much less than that credited in the safety analysis. Therefore it is recommended that the current surveillance practice of daily simple system checks, 30-day source checks and 92-day functional tests be continued in order to maintain CAM availability

  14. Co-occupant's exposure to exhaled pollutants with two types of personalized ventilation strategies under mixing and displacement ventilation systems.

    Science.gov (United States)

    Li, X; Niu, J; Gao, N

    2013-04-01

    Personalized ventilation (PV) system in conjunction with total ventilation system can provide cleaner inhaled air for the user. Concerns still exist about whether the normally protecting PV device, on the other hand, facilitates the dispersion of infectious agents generated by its user. In this article, two types of PV systems with upward supplied fresh air, namely a chair-based PV and one kind of desk-mounted PV systems, when combined with mixing ventilation (MV) and displacement ventilation (DV) systems, are investigated using simulation method with regard to their impacts on co-occupant's exposure to the exhaled droplet nuclei generated by the infected PV user. Simulation results of tracer gas and particles with aerodynamic diameter of 1, 5, and 10 μm from exhaled air show that, when only the infected person uses a PV, the different PV air supplying directions present very different impacts on the co-occupant's intake under DV, while no apparent differences can be observed under MV. The findings demonstrate that better inhaled air quality can always be achieved under DV when the adopted PV system can deliver conditioned fresh air in the same direction with the mainly upward airflow patterns of DV. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  15. Overall Ventilation System Flow Network Calculation for Site Recommendation

    International Nuclear Information System (INIS)

    Steinhoff, Jeff J.

    2001-01-01

    The scope of this calculation is to determine ventilation system resistances, pressure drops, airflows, and operating cost estimates for the Site Recommendation (SR) design as detailed in the ''Site Recommendation Subsurface Layout'' (BSC (Bechtel SAIC Company) 2001a). The statutory limit for emplacement of waste in Yucca Mountain is 70,000 metric tons of uranium (MTU) and is considered the base case for this report. The objective is to determine the overall repository system ventilation flow network for the monitoring phase during normal operations and to provide a basis for the system description document design descriptions. Any values derived from this calculation will not be used to support construction, fabrication, or procurement. The work scope is identified in the ''Technical Work Plan for Subsurface Design Section FY01 Work Activities'' (CRWMS M and O 2001, pp. 6 and 13). In accordance with the technical work plan this calculation was prepared in accordance with AP-3.12Q, ''Calculations'' and other procedures invoked by AP-3.12Q. It also incorporates the procedure AP-SI1.Q, ''Software Management''

  16. Effects of types of ventilation system on indoor particle concentrations in residential buildings.

    Science.gov (United States)

    Park, J S; Jee, N-Y; Jeong, J-W

    2014-12-01

    The objective of this study was to quantify the influence of ventilation systems on indoor particle concentrations in residential buildings. Fifteen occupied, single-family apartments were selected from three sites. The three sites have three different ventilation systems: unbalanced mechanical ventilation, balanced mechanical ventilation, and natural ventilation. Field measurements were conducted between April and June 2012, when outdoor air temperatures were comfortable. Number concentrations of particles, PM2.5 and CO2 , were continuously measured both outdoors and indoors. In the apartments with natural ventilation, I/O ratios of particle number concentrations ranged from 0.56 to 0.72 for submicron particles, and from 0.25 to 0.60 for particles larger than 1.0 μm. The daily average indoor particle concentration decreased to 50% below the outdoor level for submicron particles and 25% below the outdoor level for fine particles, when the apartments were mechanically ventilated. The two mechanical ventilation systems reduced the I/O ratios by 26% for submicron particles and 65% for fine particles compared with the natural ventilation. These results showed that mechanical ventilation can reduce exposure to outdoor particles in residential buildings. Results of this study confirm that mechanical ventilation with filtration can significantly reduce indoor particle levels compared with natural ventilation. The I/O ratios of particles substantially varied at the naturally ventilated apartments because of the influence of variable window opening conditions and unsteadiness of wind flow on the penetration of outdoor air particles. For better prediction of the exposure to outdoor particles in naturally ventilated residential buildings, it is important to understand the penetration of outdoor particles with variable window opening conditions. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Underground openings in clay formations - Technical requirements on drifting technology and support systems for underground openings and their impact on retreat systems for the installation of engineered barriers

    International Nuclear Information System (INIS)

    Mischo, Helmut

    2012-01-01

    well as the development of adapted mining and excavation methods. Other fields which have to be considered are the special requirements on the suitable support technology and systems, the necessary support installation technology and also time requirements. Most of these special requirements can also be applied to the excavation of large-scale underground openings in mud-stone and can thus provide additional information for the design and development of underground repositories in clay formations. While most information can be transferred directly from commercial mining to the excavation of a repository, there are some areas where the available data only provides some sort of basic information. One example for this is the fact that the retreat from old workings and the sealing of drifts and tunnels already requires a highly developed and adopted technology in normal clay mining operations. For the successful long-term sealing of a repository, However, the immediate expansion of the pre-stressed clay after the extraction of support units and the simultaneously starting creeping requests an even more sophisticated dam construction technology for the refinement of radioactive waste to guarantee highest quality of the dam itself. This has to include, amongst other things, excellent bonding between construction material and host rock to ensure lowest possible leakage. This paper gives a detailed overview of the technical and technological methods currently used in clay mining and the significant differences to all other types of mining operations. For each stage of the technical construction process of underground openings in clay formations it highlights the information that could be transferred to the construction of this type of underground repositories. It also shows some of the areas where the database is still limited or incomplete and thus where further research and development work is necessary for a successful technical solution for radioactive waste confinement in

  18. Industrial ventilation

    Science.gov (United States)

    Goodfellow, H. D.

    Industrial ventilation design methodology, using computers and using fluid dynamic models, is considered. It is noted that the design of a ventilation system must be incorporated into the plant design and layout at the earliest conceptual stage of the project. A checklist of activities concerning the methodology for the design of a ventilation system for a new facility is given. A flow diagram of the computer ventilation model shows a typical input, the initialization and iteration loop, and the output. The application of the fluid dynamic modeling techniques include external and internal flow fields, and individual sources of heat and contaminants. Major activities for a ventilation field test program are also addressed.

  19. 76 FR 46798 - Compatibility of Underground Storage Tank Systems With Biofuel Blends; Correction

    Science.gov (United States)

    2011-08-03

    ... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-UST-2010-0651; FRL-9447-3] Compatibility of Underground Storage Tank Systems With Biofuel Blends; Correction AGENCY: Environmental Protection Agency (EPA). ACTION: Notice; correction. SUMMARY: This document contains a typographical correction to the guidance which was...

  20. Ventilation and air-conditioning system for PWR nuclear power plant

    International Nuclear Information System (INIS)

    Ohmoto, Kenji

    1987-01-01

    This report outlines the ventilation and air conditioning facilities for PWR nuclear power plant as well as design re-evaluation and optimization of ventilation and air-conditioning. The primary PWR installations are generally housed in the nuclear reactor building, auxiliary buildings and control building, which are equipped with their own ventilation and air-conditioning systems to serve for their specific purposes. A ventilation/air-conditioning system should be able to work effectively not only for maintaining the ordinary reactor operation but also for controlling the environmental temperature in the event of an accident. Designing of a ventilation/air-conditioning system relied on empirical data in the past, but currently it is performed based on information obtained from various analyses to optimize the system configuration and ventilation capacity. Design re-evaluation of ventilation/air-conditioning systems are conducted widely in various areas, aiming at the integration of safety systems, optimum combination of air-cooling and water-cooling systems, and optimization of the ventilation rate for controlling the concentrations of radioactive substances in the atmosphere in the facilities. It is pointed out that performance evaluation of ventilation/air-conditioning systems, which has been conducted rather macroscopically, should be carried out more in detal in the future to determine optimum air streams and temperature distribution. (Nogami, K.)

  1. An air-conditioning, ventilation and automatic ventilation monitoring and recording system constructed in an unsealed radioisotope laboratory. Energy-saving measures in Nagasaki University Radioisotope Center

    International Nuclear Information System (INIS)

    Takatsuji, Toshihiro; Yoshida, Masahiro; Takao, Hideaki; Okumura, Yutaka; Ooura, Tosinobu; Kotoura, Kazuki; Yamanaka, Yasushi; Yanagita, Hiroyoshi.

    1998-01-01

    We constructed an automatic operation system of air-conditioners and ventilators in a radiation controlled area to minimize electric consumption. The system operates the air-conditioner and the ventilator of each ventilation unit when someone is staying in rooms belonging to the unit based on information from an access control system to the controlled area and lighting switches in front of individual room. For understanding of operation conditions and confirmation of radioactive concentration in air lower than the legal limit at the ventilation stack, we also constructed an automatic ventilation monitoring and recording system, which makes complete operation records of each ventilator automatically. These systems enabled to achieve sharp energy-saving compatible with radiation protection. (author)

  2. Survey execution to build a ventilation model, Australian style

    Energy Technology Data Exchange (ETDEWEB)

    Rowland, J.A. [Dallas Mining Services Pty Ltd., Wollongong, NSW (Australia)

    2010-07-01

    Ventilation surveys and the development of a properly tuned ventilation model are important components of a modern underground mine safety management system to ensure the safety of miners. Such systems in Australia revolve around the routine application of risk based logic. However, assessing the risk in ventilation systems always changes. Designers of ventilation circuits therefore use ventilation modeling software as a key tool to facilitate the structured process. This paper emphasized the importance of measuring the underground circuit and replicating the measurements in a working model. The most commonly used modeling program in Australia is the Ventsim software which is available as a fully graphical 3D configuration as well as a 2D version. The value of the mine ventilation survey lies in the ability of the data to be accurately replicated on a mine ventilation model. As such, much thought must be given to the ventilation survey scope of work and overall process. The surveys must satisfy operational needs and must delineate the circuit to a level that will allow a model be to accurately assembled in order to determine when minor or major ventilation circuit adjustments are needed. 1 ref., 10 figs.

  3. An overview of the TA-55, Building PF-4 ventilation system

    International Nuclear Information System (INIS)

    1994-01-01

    An overview of the TA-55, Building PF-4 ventilation system is provided in the following sections. Included are descriptions of the zone configurations, equipment-performance criteria, ventilation support systems, and the ventilation-system evaluation criteria. Section 4.2.1.1 provides a brief discussion of the ventilation system function. Section 4.2.1.2 provides details on the overall system configuration. Details of system interfaces and support systems are provided in Section 4.2.1.3. Section 4.2.1.4 describes instrumentation and control needed to operate the ventilation system. Finally, Sections 4.2.1.5 and 4.2.1.6 describe system surveillance/maintenance and Technical Safety Requirements (TSR) Limitations, respectively. Note that the numerical parameters included in this description are considered nominal; set points and other specifications actually fall within operational bands

  4. An overview of the TA-55, Building PF-4 ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-02-22

    An overview of the TA-55, Building PF-4 ventilation system is provided in the following sections. Included are descriptions of the zone configurations, equipment-performance criteria, ventilation support systems, and the ventilation-system evaluation criteria. Section 4.2.1.1 provides a brief discussion of the ventilation system function. Section 4.2.1.2 provides details on the overall system configuration. Details of system interfaces and support systems are provided in Section 4.2.1.3. Section 4.2.1.4 describes instrumentation and control needed to operate the ventilation system. Finally, Sections 4.2.1.5 and 4.2.1.6 describe system surveillance/maintenance and Technical Safety Requirements (TSR) Limitations, respectively. Note that the numerical parameters included in this description are considered nominal; set points and other specifications actually fall within operational bands.

  5. Ventilation and air heating systems. 5. rev. and enlarged ed. Lueftung und Luftheizung

    Energy Technology Data Exchange (ETDEWEB)

    Ihle, C. (Bundesfachschule fuer Sanitaer-, Heizungs- und Klimatechnik, Karlsruhe (Germany))

    1991-01-01

    Higher demands on the air quality of flats, offices and assembly rooms make ventilation and air heating the subjects of increasing interest. Taking into account the ever more urgent need for energy conservation the book deals with all aspects of ventilation on the basis of the recent DIN standards, VDI sheets and regulations. It may be used as an instruction manual, professional reference book or as a guide to practice-oriented subject selection with a minimum of theoretical fundamentals. The book deals with ventilation and air heating systems, free ventilation, design fundamentals, exercised for ventilation and air heating systems, central and decentralized ventilation systems, practical examples, ducts and calculation of ducts, air distribution, fans, noise formation, noise pollution abatement and heat recovery. (BWI) With 472 figs., 91 tabs., 1 separate map.

  6. Applied patent RFID systems for building reacting HEPA air ventilation system in hospital operation rooms.

    Science.gov (United States)

    Lin, Jesun; Pai, Jar-Yuan; Chen, Chih-Cheng

    2012-12-01

    RFID technology, an automatic identification and data capture technology to provide identification, tracing, security and so on, was widely applied to healthcare industry in these years. Employing HEPA ventilation system in hospital is a way to ensure healthful indoor air quality to protect patients and healthcare workers against hospital-acquired infections. However, the system consumes lots of electricity which cost a lot. This study aims to apply the RFID technology to offer a unique medical staff and patient identification, and reacting HEPA air ventilation system in order to reduce the cost, save energy and prevent the prevalence of hospital-acquired infection. The system, reacting HEPA air ventilation system, contains RFID tags (for medical staffs and patients), sensor, and reacting system which receives the information regarding the number of medical staff and the status of the surgery, and controls the air volume of the HEPA air ventilation system accordingly. A pilot program was carried out in a unit of operation rooms of a medical center with 1,500 beds located in central Taiwan from Jan to Aug 2010. The results found the air ventilation system was able to function much more efficiently with less energy consumed. Furthermore, the indoor air quality could still keep qualified and hospital-acquired infection or other occupational diseases could be prevented.

  7. Effect of an automatic triggering and cycling system on comfort and patient-ventilator synchrony during pressure support ventilation.

    Science.gov (United States)

    Vasconcelos, Renata dos S; Melo, Luíz Henrique de P; Sales, Raquel P; Marinho, Liégina S; Deulefeu, Flávio C; Reis, Ricardo C; Alves-de-Almeida, Mirizana; Holanda, Marcelo A

    2013-01-01

    The digital Auto-Trak™ system is a technology capable of automatically adjusting the triggering and cycling mechanisms during pressure support ventilation (PSV). To compare Auto-Trak with conventional settings in terms of patient-ventilator synchrony and discomfort. Twelve healthy volunteers underwent PSV via the mouth by breathing through an endotracheal tube. In the conventional setting, a pressure support of 8 cm H2O with flow cycling (25% peak inspiratory flow) and a sensitivity of 1 cm H2O was adjusted. In Auto-Trak the triggering and cycling were automatically set. Discomfort, effort of breathing, and the asynchrony index (AI) were assessed. In a complementary bench study, the inspiratory and expiratory time delays were quantified for both settings in three mechanical models: 'normal', obstructive (COPD), and restrictive (ARDS), using the ASL 5000 simulator. In the volunteer study the AI and the discomfort scores did not differ statistically between the two settings. In the bench investigation the use of Auto-Trak was associated with a greater triggering delay in the COPD model and earlier expiratory cycling in the ARDS model but with no asynchronic events. Use of the Auto-Trak system during PSV showed similar results in comparison to the conventional adjustments with respect to patient-ventilator synchrony and discomfort in simulated conditions of invasive mechanical ventilation. Copyright © 2013 S. Karger AG, Basel.

  8. Building America Case Study: Selecting Ventilation Systems for Existing Homes (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2014-12-01

    This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

  9. Performance analysis of a new design of office diffuse ceiling ventilation system

    DEFF Research Database (Denmark)

    Fan, Jianhua; Hviid, Christian Anker; Yang, Honglu

    2013-01-01

    surface temperatures, pressure loss of the ceiling and ventilation effectiveness are measured for an air change rate of 3.5 h-1 and 5.1 h -1 respectively. A computational fluid dynamics model of the office with the diffuse ceiling ventilation system is built and validated by the full scale measurement....... The measurements of pressure loss across the ceiling show a low pressure drop between the plenum and the occupied zone. Ventilation effectiveness is measured to be close to 1 on average under the tested conditions. It is shown that the diffuse ceiling ventilation system is able to remove indoor pollutant...

  10. Performance analysis of ventilation systems with desiccant wheel cooling based on exergy destruction

    International Nuclear Information System (INIS)

    Tu, Rang; Liu, Xiao-Hua; Hwang, Yunho; Ma, Fei

    2016-01-01

    Highlights: • Ventilation systems with desiccant wheel were analyzed from exergy destruction. • Main performances influencing factors for ventilation systems are put forward. • Improved ventilation systems with lower exergy destruction are suggested. • Performances of heat pumps driven ventilation systems are greatly increased. - Abstract: This paper investigates the performances of ventilation systems with desiccant wheel cooling from the perspective of exergy destructions. Based on the inherent influencing factors for exergy destructions of heat and mass transfer and heat sources, provide guidelines for efficient system design. First, performances of a basic ventilation system are simulated, which is operated at high regeneration temperature and low coefficient of performance (COP). Then, exergy analysis of the basic ventilation system shows that exergy destructions mainly exist in the heat and mass transfer components and the heat source. The inherent influencing factors for the heat and mass transfer exergy destruction are heat and mass transfer capacities, which are related to over dehumidification of the desiccant wheel, and unmatched coefficients, which represent the uniformity of the temperature or humidity ratio differences fields for heat and mass transfer components. Based on these findings, two improved ventilation systems are suggested. For the first system, over dehumidification is avoided and unmatched coefficients for each component are reduced. With lower heat and mass transfer exergy destructions and lower regeneration temperature, COP and exergy efficiency of the first system are increased compared with the basic ventilation system. For the second system, a heat pump, which recovers heat from the process air to heat the regeneration air, is adopted to replace the electrical heater and cooling devices. The exergy destruction of the heat pump is considerably reduced as compared with heat source exergy destruction of the basic ventilation

  11. A new prototype of an electronic jet-ventilator and its humidification system

    Science.gov (United States)

    Kraincuk, Paul; Kepka, Anton; Ihra, Gerald; Schabernig, Christa; Aloy, Alexander

    1999-01-01

    Background: Adequate humidification in long-term jet ventilation is a critical aspect in terms of clinical safety. Aim: To assess a prototype of an electronic jet-ventilator and its humidification system. Methods: Forty patients with respiratory insufficiency were randomly allocated to one of four groups. The criterion for inclusion in this study was respiratory insufficiency exhibiting a Murray score above 2. The four groups of patients were ventilated with three different respirators and four different humidification systems. Patients in groups A and B received superimposed high-frequency jet ventilation (SHFJV) by an electronic jet-ventilator either with (group A) or without (group B) an additional humidification system. Patients in group C received high-frequency percussive ventilation (HFPV) by a pneumatic high-frequency respirator, using a hot water humidifier for warming and moistening the inspiration gas. Patients in group D received conventional mechanical ventilation using a standard intensive care unit respirator with a standard humidification system. SHFJV and HFPV were used for a period of 100 h (4days). Results: A significantly low inspiration gas temperature was noted in patients in group B, initially (27.2 ± 2.5°C) and after 2 days (28.0 ± 1.6°C) (P humidification associated with jet ventilation can be fully prevented by using this new jet-ventilator. These data were sustained by nondeteriorating MIS values at the end of the 4-day study period in groups A, C and D. PMID:11056732

  12. Causes Of Low Efficiency Of Combined Ventilation System In Coal Mines In Resolving The Problem Of Air Leaks (Inflows) Between Levels And Surface

    Science.gov (United States)

    Popov, Valeriy; Filatov, Yuriy; Lee, Hee; Golik, Anatoliy

    2017-11-01

    The paper discusses the problem of the underground mining safety control. The long-term air intake to coal accumulations is reviewed as one of the reasons of endogenous fires during mining. The methods of combating air leaks (inflows) in order to prevent endogenous fires are analyzed. The calculations showing the discrepancy between the design calculations for the mine ventilation, disregarding a number of mining-andgeological and mining-engineering factors, and the actual conditions of mining are given. It is proved that the conversion of operating mines to combined (pressure and exhaust) ventilation system in order to reduce the endogenous fire hazard of underground mining is unreasonable due to impossibility of providing an optimal distribution of aerodynamic pressure in mines. The conversion does not exclude the entry of air into potentially hazardous zones of endogenous fires. The essence of the combined application of positive and negative control methods for the distribution of air pressure is revealed. It consists of air doors installation in easily ventilated airways and installation of pressure equalization chambers equipped with auxiliary fans near the stoppings, working sections and in parallel airways.The effectiveness of the combined application of negative and positive control methods for the air pressure distribution in order to reduce endogenous fire hazard of mining operations is proved.

  13. Causes Of Low Efficiency Of Combined Ventilation System In Coal Mines In Resolving The Problem Of Air Leaks (Inflows Between Levels And Surface

    Directory of Open Access Journals (Sweden)

    Popov Valeriy

    2017-01-01

    Full Text Available The paper discusses the problem of the underground mining safety control. The long-term air intake to coal accumulations is reviewed as one of the reasons of endogenous fires during mining. The methods of combating air leaks (inflows in order to prevent endogenous fires are analyzed. The calculations showing the discrepancy between the design calculations for the mine ventilation, disregarding a number of mining-andgeological and mining-engineering factors, and the actual conditions of mining are given. It is proved that the conversion of operating mines to combined (pressure and exhaust ventilation system in order to reduce the endogenous fire hazard of underground mining is unreasonable due to impossibility of providing an optimal distribution of aerodynamic pressure in mines. The conversion does not exclude the entry of air into potentially hazardous zones of endogenous fires. The essence of the combined application of positive and negative control methods for the distribution of air pressure is revealed. It consists of air doors installation in easily ventilated airways and installation of pressure equalization chambers equipped with auxiliary fans near the stoppings, working sections and in parallel airways.The effectiveness of the combined application of negative and positive control methods for the air pressure distribution in order to reduce endogenous fire hazard of mining operations is proved.

  14. Instability risk analysis and risk assessment system establishment of underground storage caverns in bedded salt rock

    Science.gov (United States)

    Jing, Wenjun; Zhao, Yan

    2018-02-01

    Stability is an important part of geotechnical engineering research. The operating experiences of underground storage caverns in salt rock all around the world show that the stability of the caverns is the key problem of safe operation. Currently, the combination of theoretical analysis and numerical simulation are the mainly adopts method of reserve stability analysis. This paper introduces the concept of risk into the stability analysis of underground geotechnical structure, and studies the instability of underground storage cavern in salt rock from the perspective of risk analysis. Firstly, the definition and classification of cavern instability risk is proposed, and the damage mechanism is analyzed from the mechanical angle. Then the main stability evaluating indicators of cavern instability risk are proposed, and an evaluation method of cavern instability risk is put forward. Finally, the established cavern instability risk assessment system is applied to the analysis and prediction of cavern instability risk after 30 years of operation in a proposed storage cavern group in the Huai’an salt mine. This research can provide a useful theoretical base for the safe operation and management of underground storage caverns in salt rock.

  15. Experimental evaluation of the Skylab orbital workshop ventilation system concept

    Science.gov (United States)

    Allums, S. L.; Hastings, L. J.; Ralston, J. T.

    1972-01-01

    Extensive testing was conducted to evaluate the Orbital Workshop ventilation concept. Component tests were utilized to determine the relationship between operating characteristics at 1 and 0.34 atm. System tests were conducted at 1 atm within the Orbital Workshop full-scale mockup to assess delivered volumetric flow rate and compartment air velocities. Component tests with the Anemostat circular diffusers (plenum- and duct-mounted) demonstrated that the diffuser produced essentially equivalent airflow patterns and velocities in 1- and 0.34-atm environments. The tests also showed that the pressure drop across the diffuser could be scaled from 1 to 0.34 atm using the atmosphere pressure ratio. Fan tests indicated that the performance of a multiple, parallel-mounted fan cluster could be predicted by summing the single-fan flow rates at a given delta P.

  16. Effect of Room Ventilation Rates in Rodent Rooms with Direct-Exhaust IVC Systems.

    Science.gov (United States)

    Geertsema, Roger S; Lindsell, Claire E

    2015-09-01

    When IVC are directly exhausted from a rodent housing room, the air quality of the room can become independent of the intracage air quality and may reduce the need for high room ventilation rates. This study assessed the effect of decreasing the ventilation rate in rodent rooms using direct-exhaust IVC systems. The study was conducted over 16 wk and compared conditions in 8 rodent rooms that had ventilation rates of 5 to 6 air changes per hour (ACH) with those in rooms at 10 to 12 ACH. At the low ventilation rate, rooms had higher CO₂ concentrations, higher dew point temperature, and lower particulate levels and spent a greater percentage of time above the temperature set point than did rooms at the high rate. The levels of allergens and endotoxins in room air were the same regardless of the ventilation rate. Differences seen in parameters within cages at the 2 ventilation rates were operationally irrelevant. We detected no total volatile organic compounds in the room that were attributable to ammonia, regardless of the ventilation rate. Clearing the air of ethanol after a spill took longer at the low compared with high rate. However, ethanol clearance was faster at the low rate when the demand-control system was activated than at the high ventilation rate alone. Air quality in the room and in the cages were acceptable with room ventilation rates of 5 to 6 ACH in rodent rooms that use direct-exhaust IVC systems.

  17. Analysis on present radon ventilation situation of Chinese uranium mines

    International Nuclear Information System (INIS)

    Li Xianjie; Hu Penghua

    2010-01-01

    Mine Ventilation is the most important way in lowering radon of uranium mines. At present, radon and radon daughter concentration of underground air is 3∼5 times higher than any other air concentration of foreign uranium mines, as the same input for Protective Ventilation between Chinese uranium mines with compaction methodology and international advanced uranium mines. In this passage, through the analysis of Ventilation Radon Reduction status in Chinese uranium mines and the comparison of advantages and shortcomings between variety of ventilation and radon reduction, it illuminated the reasons of higher radon and radon daughter concentration in Chinese uranium mines and put forward some problems in three aspects, which are Ventilation Radon Reduction Theory, Ventilation Radon Reduction Measures and Ventilation Management. And to above problems, this passage put forward some proposals and measures about some aspects, such as strengthen examination and verification and monitoring practical situation, making clear ventilation plan, in according to mining sequence strictly, training Ventilation technician forcefully, enhance Ventilation System management, development of Ventilation Radon Reduction technology research in uranium mines and carrying out ventilation equipments as soon as possible in further and so on. (authors)

  18. An energy-efficient underground localization system based on heterogeneous wireless networks.

    Science.gov (United States)

    Yuan, Yazhou; Chen, Cailian; Guan, Xinping; Yang, Qiuling

    2015-05-26

    A precision positioning system with energy efficiency is of great necessity for guaranteeing personnel safety in underground mines. The location information of the miners' should be transmitted to the control center timely and reliably; therefore, a heterogeneous network with the backbone based on high speed Industrial Ethernet is deployed. Since the mobile wireless nodes are working in an irregular tunnel, a specific wireless propagation model cannot fit all situations. In this paper, an underground localization system is designed to enable the adaptation to kinds of harsh tunnel environments, but also to reduce the energy consumption and thus prolong the lifetime of the network. Three key techniques are developed and implemented to improve the system performance, including a step counting algorithm with accelerometers, a power control algorithm and an adaptive packets scheduling scheme. The simulation study and experimental results show the effectiveness of the proposed algorithms and the implementation.

  19. An Energy-Efficient Underground Localization System Based on Heterogeneous Wireless Networks

    Directory of Open Access Journals (Sweden)

    Yazhou Yuan

    2015-05-01

    Full Text Available A precision positioning system with energy efficiency is of great necessity for guaranteeing personnel safety in underground mines. The location information of the miners’ should be transmitted to the control center timely and reliably; therefore, a heterogeneous network with the backbone based on high speed Industrial Ethernet is deployed. Since the mobile wireless nodes are working in an irregular tunnel, a specific wireless propagation model cannot fit all situations. In this paper, an underground localization system is designed to enable the adaptation to kinds of harsh tunnel environments, but also to reduce the energy consumption and thus prolong the lifetime of the network. Three key techniques are developed and implemented to improve the system performance, including a step counting algorithm with accelerometers, a power control algorithm and an adaptive packets scheduling scheme. The simulation study and experimental results show the effectiveness of the proposed algorithms and the implementation.

  20. Passive ventilation systems with heat recovery and night cooling

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2008-01-01

    In building design the requirements for energy consumption for ventilation, heating and cooling and the requirements for increasingly better indoor climate are two opposing factors. This paper presents the schematic layout and simulation results of an innovative multifunc-tional ventilation conce...

  1. Underground Water Distribution System, Fort Belvoir, Virginia. Leak Detection Survey

    National Research Council Canada - National Science Library

    1995-01-01

    .... The survey was conducted by myself, Donald Muir, Operations Coordinator, and required 12.25 working days. This was not a survey of the entire water distribution system but instead a survey of water mains 8 inch and larger...

  2. Geologic considerations in underground coal mining system design

    Science.gov (United States)

    Camilli, F. A.; Maynard, D. P.; Mangolds, A.; Harris, J.

    1981-01-01

    Geologic characteristics of coal resources which may impact new extraction technologies are identified and described to aid system designers and planners in their task of designing advanced coal extraction systems for the central Appalachian region. These geologic conditions are then organized into a matrix identified as the baseline mine concept. A sample region, eastern Kentucy is analyzed using both the developed baseline mine concept and the traditional geologic investigative approach.

  3. Analysis of the systems of ventilation of residential houses of Ukraine and Estonia

    Science.gov (United States)

    Savchenko, Olena; Zhelykh, Vasyl; Voll, Hendrik

    2017-12-01

    The most common ventilation system in residential buildings in Ukraine is natural ventilation. In recent years, due to increased tightness of structures, an increase in the content of synthetic finishing materials in them, the quality of microclimate parameters deteriorated. One of the measures to improve the parameters of indoor air in residential buildings is the use of mechanical inflow and exhaust ventilation system. In this article the regulatory documents concerning the design of ventilation systems in Ukraine and Estonia and the requirements for air exchange in residential buildings are considered. It is established that the existing normative documents in Ukraine are analogous to European norms, which allow design the system of ventilation of residential buildings according to European standards. However, the basis for the design of ventilation systems in Ukraine is the national standards, in which mechanical ventilation, unfortunately, is provided only for the design of high-rise buildings. To maintain acceptable microclimate parameters in residential buildings, it is advisable for designers to apply the requirements for designing ventilation systems in accordance with European standards.

  4. Analysis of the systems of ventilation of residential houses of Ukraine and Estonia

    Directory of Open Access Journals (Sweden)

    Savchenko Olena

    2017-12-01

    Full Text Available The most common ventilation system in residential buildings in Ukraine is natural ventilation. In recent years, due to increased tightness of structures, an increase in the content of synthetic finishing materials in them, the quality of microclimate parameters deteriorated. One of the measures to improve the parameters of indoor air in residential buildings is the use of mechanical inflow and exhaust ventilation system. In this article the regulatory documents concerning the design of ventilation systems in Ukraine and Estonia and the requirements for air exchange in residential buildings are considered. It is established that the existing normative documents in Ukraine are analogous to European norms, which allow design the system of ventilation of residential buildings according to European standards. However, the basis for the design of ventilation systems in Ukraine is the national standards, in which mechanical ventilation, unfortunately, is provided only for the design of high-rise buildings. To maintain acceptable microclimate parameters in residential buildings, it is advisable for designers to apply the requirements for designing ventilation systems in accordance with European standards.

  5. Controlling the Distribution of Cold Water in Air Cooling Systems of Underground Mines

    Science.gov (United States)

    Szlązak, Nikodem; Obracaj, Dariusz; Swolkień, Justyna; Piergies, Kazimierz

    2016-12-01

    In Polish underground mines in which excavations are subjected to high heat load, central and group cooling systems based on indirect cooling units are implemented. Chilled water, referred to as cold water and produced in chillers, is distributed through a pipeline network to air coolers located in mining and development districts. The coolers are often moved to other locations and the pipeline network undergoes constant modification. In such a system, parameters of cold water in different branches of the pipeline network need to be controlled. The article presents the principles for controlling the cooling capacity of air coolers installed in an underground mine. Also, the authors propose automatic control of water flow rate in underground pipeline network and in particular coolers, depending on the temporary cooling load in the system. The principles of such a system, controlling cold water distribution, and the functions of its individual components are described. Finally, an example of an automatic control of water flow rate in a central cooling system currently implemented in a mine is presented.

  6. EHV/HV Underground Cable Systems for Power Transmission

    DEFF Research Database (Denmark)

    Bak, Claus Leth

    the role of interconnecting these generation/load centres, ensuring fair reliability and redundancy of supply. Nowadays, the power transmission system must be able to handle the various sources of renewable generation in a flexible electricity market. This has the consequence that the original layout...... are to be found. One very good example of this is offshore wind power plants. The current transmission system is laid out in a traditional manner, which is based on the idea of not transporting power over longer distances as the power plants have been located near centres of consumption. It has merely played...... of the transmission system must be re‐thought in order to accommodate the transmission needs for the future. New lines have to be constructed. Transmission lines are usually laid out as overhead lines, which are large structures, i.e. a 400 kV power pylon is 50 meters high. According to public opinion, such power...

  7. Computer-simulation study on fire behaviour in the ventilated cavity of ventilated façade systems

    Directory of Open Access Journals (Sweden)

    Giraldo María P.

    2013-11-01

    Full Text Available Fire spread through the façades is widely recognized as one of the fastest pathways of fire spreading in the buildings. Fire may spread through the façade in different ways depending on the type of façade system and on the elements and materials from which it is constructed. Ventilated façades are multilayer systems whose main feature is the creation of an air chamber of circulating air between the original building wall and the external cladding. The “chimney effect” in the air cavity is a mechanism that improves the façade's thermal behaviour and avoids the appearance of moisture from rain or condensation. However, in a event of fire, it may contribute to the quickest spreading of fire, representing a significant risk to the upper floors of a building. This study deals with some aspects of fire propagation through the ventilated cavity in ventilated façade systems. Also we review the provisions stipulated by the Spanish building code (Código Técnico de la Edificación, CTE [1] to avoid fire spread outside the building. The results highlight the importance of the use of proper fire barriers to ensure the compartmentalization of the ventilated cavity, as well as the use of non-combustible thermal insulation materials, among others. In addition, based on the results, it might be considered that the measures stipulated by the CTE are insufficient to limit the risks associated with this kind of façades systems. The study has been performed using field models of computational fluid-dynamics. In particular, the Fire Dynamics Simulator (FDS software has been used to numerically solve the mathematical integration models.

  8. Complex photonic system for underground railway measurements and inspection

    Science.gov (United States)

    Giltsov, Victor S.; Inozemtsev, Vladimir G.; Popov, Sergey V.; Titov, Evgeny V.; Shilin, Victor A.

    2002-04-01

    Moscow Metro is a powerful and important type of city transportation. Novel photonic gauge consisting of three subsystems for inspection of railway geometrical parameters is presented. Each system includes special lasers, CCD cameras and signal processor. Desired parameters are determined using processing of images formed by lasers. Mathematical methods and software for processing are described. Some experimental results are given.

  9. Mine Ventilation System Variable Resistance Regulate Air Quantity Economy and Its Impacts on Artisanal Mine in Ivory Coast

    Directory of Open Access Journals (Sweden)

    Kouame Kouame Arthur Joseph

    2016-01-01

    Full Text Available The artisanal gold mining is one of the major illegal activities in Ivory Coast. Thousands of indigents and foreigners including men, women and children are involved in this dangerous activity. Contracting contagious diseases such as HIV/AIDS and multiple lung diseases are commonplace on the artisanal mining sites due to air pollution. For this reason, the differential analysis, research mine ventilation system by changing the working windage adjustment for air flow of the economy, identifies factors, obtained discriminant variable resistance air volume control economic quantitative criteria for underground actual situation of joint variable resistance method and economic variable resistance than the concept of the development of effective mine ventilation system to improve air quantity adjusting rheostat economical way. The findings of this study can help lead to better safety practices in mining in order to improve the health and safety of the miners who are involved in artisanal mining activities in Ivory Coast and other mining sites over the world.

  10. Development and Improvement of an Intelligent Cable Monitoring System for Underground Distribution Networks Using Distributed Temperature Sensing

    Directory of Open Access Journals (Sweden)

    Jintae Cho

    2014-02-01

    Full Text Available With power systems switching to smart grids, real-time and on-line monitoring technologies for underground distribution power cables have become a priority. Most distribution components have been developed with self-diagnostic sensors to realize self-healing, one of the smart grid functions in a distribution network. Nonetheless, implementing a real-time and on-line monitoring system for underground distribution cables has been difficult because of high cost and low sensitivity. Nowadays, optical fiber composite power cables (OFCPCs are being considered for communication and power delivery to cope with the increasing communication load in a distribution network. Therefore, the application of distributed temperature sensing (DTS technology on OFCPCs used as underground distribution lines is studied for the real-time and on-line monitoring of the underground distribution power cables. Faults can be reduced and operating ampacity of the underground distribution system can be increased. This paper presents the development and improvement of an intelligent cable monitoring system for the underground distribution power system, using DTS technology and OFCPCs as the underground distribution lines in the field.

  11. 78 FR 35975 - Proposed Information Collection; Comment Request; Safety Standards for Underground Coal Mine...

    Science.gov (United States)

    2013-06-14

    ... Request; Safety Standards for Underground Coal Mine Ventilation--Belt Entry Used as an Intake Air Course... collection related to the Safety Standards for Underground Coal Mine Ventilation--Belt Entry Used as an... Administration. Title: Safety Standards for Underground Coal Mine Ventilation--Belt Entry Used as an Intake Air...

  12. Development of a GIS-based monitoring and management system for underground coal mining safety

    Energy Technology Data Exchange (ETDEWEB)

    Salap, Seda; Karslioglu, Mahmut Onur [Civil Engineering Department, Geomatics Division, Middle East Technical University, Ankara (Turkey); Demirel, Nuray [Mining Engineering Department, Middle East Technical University, Ankara (Turkey)

    2009-11-01

    Coal mine safety is of paramount concern to mining industry. Mine accidents have various causes and consequences including catastrophic failure of mine, substantial economic losses and most notably loss of lives. Therefore, any initiative in mine monitoring is of vital importance for progressing safety surveillance and maintenance. This paper presents the development of a geographic information system (GIS)-based monitoring and management system for underground mine safety in three levels as constructive safety, surveillance and maintenance, and emergency. The developed model integrates the database design and management to the monitoring system implementation which encompasses query and analysis operations with the help of web and desktop applications. Interactive object-oriented graphical user interfaces (GUIs) were developed to visualize information about the entities gathered from the model and also to provide analysis operations based on the graphical representations and demonstrations using data tables and map objects. The research methodology essentially encompasses five main stages: (i) designing a conceptual database model; (ii) development of a logical model in terms of entity-relationship (ER) diagrams; (iii) development of a physical model based on physical constraints and requirements; (iv) development of GUIs and implementation of the developed model, analysis and queries; (v) verification and validation of the created model for Oemerler underground coal mine in Turkey. The proposed system is expected to be an efficient tool for improving and maintaining healthy standards in underground coal mines which can possibly be extended to a national GIS infrastructure. (author)

  13. Developing and improving underground haulage system in the Raspadskaya mine

    Energy Technology Data Exchange (ETDEWEB)

    Bol' shanin, N.I.; Sergienko, A.N.; Bakhtin, V.N.

    1980-06-01

    Coal haulage system in the Raspadskaya coal mine consists of several belt conveyors and vertical spiral chute conveyors. 1LT-80 and 2L-80 belt conveyors hauling coal from working faces cooperate with: PTK-1 and 1KSP-2 loaders; in breaking inclined planes 1LB-100, 2LB-120, 1LU-100 and 2LU-100 conveyors, which haul coal to the spiral chute conveyors, are installed. Capacity of a spiral chute conveyor is 700 t/h. The Raspadskaya haulage system is fully based on belt conveyors. One of its features is lack of storage capacity which could be used if the quantity of transported materials is temporarily higher than the haulage capacity of conveyors and chutes. Haulage capacity of both conveyors and spiral chutes is analyzed. In the case of conveyors their capacity depends mainly on width of the belt and speed of movement, and capacity of spiral chutes depends to a significant degree not only on size but also on moisture content in coal. When coal moisture increases from 3% to 8% haulage capacity decreases by 17 to 7 t/min. Some construction changes of the chutes are proposed which would prolong their service life 2 to 2.5 times. Proposals for modernizing the mine's haulage system are also made. They consist of: using belt conveyors with increased haulage capacity, modernizing spiral chutes and constructing temporary coal bunkers which could be used when haulage capacity of conveyors is lower than the flow of coal and rock.

  14. RECOMMENDATIONS ON THE MONITORING SYSTEM OF UNDERGROUND GAS STORAGE (in Russian

    Directory of Open Access Journals (Sweden)

    Victor NORDIN

    2014-07-01

    Full Text Available The article in accordance with the "process approach" ISO 9000 is substantiated the necessity of creating underground gas storage system monitoring and control, including objects, parameters, methods, frequency and corrective action, on the basis of which made structural formula monitoring cycle. Qualimetrical approach allows to define complex criteria of an estimation of efficiency of operation, which will help to make timely and effective management decisions, including from the perspective of environmental protection.

  15. Development of cycloconverter-IM system for explosion-proof underground mine hoist

    Energy Technology Data Exchange (ETDEWEB)

    Xie Guilin; Zhao Yifan (China University of Mining Technology, Xuzhou (China). Dept. of Automation Engineering)

    1990-12-01

    A recently developed Cycloconverter-IM haulage drive for underground mining is described in this paper. The control of this system is fully digitized. Six INTEL 8031 single-chip microprocessors are interconnected to perform the functions of motor speed control, cycloconverter firing, fault diagnosis, etc. The implementations of the above functions are illustrated, and also a new method called 'slip feedback control' for improving power factor of cycloconverter is put forward. 3 refs., 5 figs.

  16. 30 CFR 57.8519 - Underground main fan controls.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground main fan controls. 57.8519 Section... Ventilation Surface and Underground § 57.8519 Underground main fan controls. All underground main fans shall have controls placed at a suitable protected location remote from the fan and preferably on the surface...

  17. A novel system solution for cooling and ventilation in office buildings

    DEFF Research Database (Denmark)

    Yu, Tao; Heiselberg, Per Kvols; Lei, Bo

    2015-01-01

    technologies and renewable energy sources have risen. Based on a literature review of natural ventilation, building thermal mass activation and diffuse ceiling ventilation, this paper proposes a new system solution combining these three technologies for cooling and ventilation in office buildings. This new...... solution has the special function of using natural ventilation all the year around without draught risk, even in very cold seasons. A case study of a typical office room using this solution and other traditional HVAC systems is carried out by energy simulation. The results show that there is a large energy...... saving potential using this solution compared with other systems. Energy saving potential for cooling occurs in summer, transitional seasons and part of winter, depending on the internal heat load level. Meanwhile, due to the large cooling potential of outside air in winter, the minimum ventilation rate...

  18. Underground Storage Tank (working)

    Data.gov (United States)

    Vermont Center for Geographic Information — Database contains information on ownership and system construction for underground storage tank facilities statewide. Database was developed in early 1990's for...

  19. Noxious gases in rabbit housing systems: effects of cross and longitudinal ventilation

    Directory of Open Access Journals (Sweden)

    Francesco da Borso

    2016-12-01

    Full Text Available Animal welfare is a matter of increasing interest due to ethical and economical worries regarding animal rights and the sustainability of meat production. Ammonia, carbon dioxide, and methane can be produced in the livestock buildings and, if not adequately controlled by ventilation, can be dangerous for animals and farmers. The aim of the present paper is to study the effects of different ventilation systems in rabbit buildings based on the temporal patterns and the spatial distribution of these noxious gases. The experimental measurements were conducted in two rabbit farms with genetically homogeneous animals subjected to the same diet. Two buildings with different forced ventilation layouts (cross ventilation - building A and longitudinal ventilation - building B were subjected to the monitoring of indoor environmental conditions (temperature, relative humidity, ammonia, carbon dioxide, methane over a whole year. In both the buildings, ventilation was adjusted automatically by means of electronic control units, which were controlled by temperature sensors, located at the centre of the buildings. Gas concentrations inside the buildings followed clearly defined sinusoidal patterns on a daily basis with the highest values reached in winter during the morning hours for ammonia and during the night hours for carbon dioxide and methane. In particular, ammonia revealed a maximum concentration of 30.7 mg m–3 in building A (cross ventilation and 12.9 mg m–3 in building B (longitudinal ventilation, whereas the minimum values were 6.0 and 4.2 mg m–3, in building A and B, respectively. As a consequence, daily mean concentrations of noxious gases, solely could not be considered representative of the actual conditions of air quality in the buildings. The airflow direction clearly influenced the spatial concentration of ammonia, which showed different patterns in the two buildings. In building A, the highest ammonia concentration was in a diffuse

  20. An Evaluation of a Proposed Ventilation System for Melbourne's CH2 Building

    Directory of Open Access Journals (Sweden)

    Lu Aye

    2012-11-01

    Full Text Available The understanding of ventilation requirements in commercial buildings has been significantly revised in the last 10-15 years. A link between health, productivity and increased fresh air use has been established by some research and this understanding underpins the ventilation philosophy adopted for the CH2 building. The ventilation system design for CH2 that has been evaluated in this paper envisages a mechanically driven system during the day, using the displacement technique to distribute filtered air. All introduced air will be drawn from outside and no recycling of air will occur. Natural ventilation will be employed at night using the stack effect, enhanced by turbine ventilators. This paper critiques the proposed ventilation system in the light of international experience and the particular conditions of the building's location. The evidence suggests that natural ventilation sometimes may be inadequate to achieve the desired objectives. Minimization of indoor pollutants, adequate filtration and high levels of ventilation should, however, ensure satisfactory air quality during occupied hours.

  1. TVENT: a computer program for analysis of tornado-induced transients in ventilation systems

    International Nuclear Information System (INIS)

    Duerre, K.H.; Andrae, R.W.; Gregory, W.S.

    1978-07-01

    The report describes TVENT, a portable FORTRAN computer program for predicting flows and pressures in a ventilation system subject to a tornado. The pressure and flow values calculated by TVENT can be used as a basis for structural analysis. TVENT is a one-dimensional, lumped-parameter model with incompressible flow augmented by fluid storage. The theoretical basis for the mathematical modeling and analysis is presented, and a description of the input for the computer code is provided. Modeling techniques specific to ventilation systems are described. Sample problems illustrate the use of TVENT in analyzing ventilation systems. Other sample problems illustrate modeling techniques used in reducing complex systems

  2. Cooperative Behaviours with Swarm Intelligence in Multirobot Systems for Safety Inspections in Underground Terrains

    Directory of Open Access Journals (Sweden)

    Chika Yinka-Banjo

    2014-01-01

    Full Text Available Underground mining operations are carried out in hazardous environments. To prevent disasters from occurring, as often as they do in underground mines, and to prevent safety routine checkers from disasters during safety inspection checks, multirobots are suggested to do the job of safety inspection rather than human beings and single robots. Multirobots are preferred because the inspection task will be done in the minimum amount of time. This paper proposes a cooperative behaviour for a multirobot system (MRS to achieve a preentry safety inspection in underground terrains. A hybrid QLACS swarm intelligent model based on Q-Learning (QL and the Ant Colony System (ACS was proposed to achieve this cooperative behaviour in MRS. The intelligent model was developed by harnessing the strengths of both QL and ACS algorithms. The ACS optimizes the routes used for each robot while the QL algorithm enhances the cooperation between the autonomous robots. A description of a communicating variation within the QLACS model for cooperative behavioural purposes is presented. The performance of the algorithms in terms of without communication, with communication, computation time, path costs, and the number of robots used was evaluated by using a simulation approach. Simulation results show achieved cooperative behaviour between robots.

  3. Morpho-anatomical features of underground systems in six Asteraceae species from the Brazilian Cerrado.

    Science.gov (United States)

    Appezzato-da-Glória, Beatriz; Cury, Graziela

    2011-09-01

    In the Brazilian Cerrado (neotropical savanna), the development of bud-bearing underground systems as adaptive structures to fire and dry periods can comprise an important source of buds for this ecosystem, as already demonstrated in the Brazilian Campos grasslands and North American prairies. Asteraceae species from both woody and herbaceous strata have subterranean organs that accumulate carbohydrates, reinforcing the adaptive strategy of these plants to different environmental conditions. This study aims to analyse the morpho-anatomy of underground systems of six species of Asteraceae (Mikania cordifolia L.f. Willd., Mikania sessilifolia DC, Trixis nobilis (Vell.) Katinas, Pterocaulon alopecuroides (Lam.) DC., Vernonia elegans Gardner and Vernonia megapotamica Spreng.), to describe these structures and to verify the occurrence and origin of shoot buds, and to analyse the presence of reserve substances. Individuals sampled in Cerrado areas in São Paulo State showed thick underground bud-bearing organs, with adventitious or lateral roots and presence of fructans. Xylopodium was found in all studied species, except for Trixis nobilis, which had stem tuber. The presence of fructans as reserve, and the capacity of structures in the formation of buds indicate the potential of herbaceous species of Asteraceae in forming a viable bud bank for vegetation regeneration in the Brazilian Cerrado.

  4. A Wireless LAN and Voice Information System for Underground Coal Mine

    Directory of Open Access Journals (Sweden)

    Yu Zhang

    2014-06-01

    Full Text Available In this paper we constructed a wireless information system, and developed a wireless voice communication subsystem based on Wireless Local Area Networks (WLAN for underground coal mine, which employs Voice over IP (VoIP technology and Session Initiation Protocol (SIP to achieve wireless voice dispatching communications. The master control voice dispatching interface and call terminal software are also developed on the WLAN ground server side to manage and implement the voice dispatching communication. A testing system for voice communication was constructed in tunnels of an underground coal mine, which was used to actually test the wireless voice communication subsystem via a network analysis tool, named Clear Sight Analyzer. In tests, the actual flow charts of registration, call establishment and call removal were analyzed by capturing call signaling of SIP terminals, and the key performance indicators were evaluated in coal mine, including average subjective value of voice quality, packet loss rate, delay jitter, disorder packet transmission and end-to- end delay. Experimental results and analysis demonstrate that the wireless voice communication subsystem developed communicates well in underground coal mine environment, achieving the designed function of voice dispatching communication.

  5. Radon mitigation in schools utilising heating, ventilating and air conditioning systems

    International Nuclear Information System (INIS)

    Fisher, G.; Ligman, B.; Brennan, T.; Shaughnessy, R.; Turk, B.H.; Snead, B.

    1994-01-01

    As part of a continuing radon in schools technology development effort, EPA's School Evaluation Team has performed radon mitigation in schools by the method of ventilation/pressurisation control technology. Ventilation rates were increased, at a minimum, to meet the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) standard, Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1989). This paper presents the results and the preliminary evaluations which led to the team's decision to implement this technology. Factors considered include energy penalties, comfort, indoor air quality (IAQ), building shell tightness, and equipment costs. Cost benefit of heat recovery ventilation was also considered. Earlier results of the SEP team's efforts have indicated a severe ventilation problem within the schools of the United States. Two case studies are presented where HVAC technology was implemented for controlling radon concentrations. One involved the installation of a heat recovery ventilator to depressurise a crawl space and provide ventilation to the classrooms which previously had no mechanical ventilation. The other involved the restoration of a variable air volume system in a two-storey building. The HVAC system's controls were restored and modified to provide a constant building pressure differential to control the entry of radon. Pre-mitigation and post-mitigation indoor air pollutant measurements were taken, including radon, carbon dioxide (CO 2 ), particulates, and bio-aerosols. Long-term monitoring of radon, CO 2 , building pressure differentials, and indoor/outdoor temperature and relative humidity is presented. (author)

  6. An experimental study of the exergetic performance of an underground air tunnel system for greenhouse cooling

    International Nuclear Information System (INIS)

    Ozgener, Leyla; Ozgener, Onder

    2010-01-01

    The present study highlights the exergetic performance characteristics of an underground air tunnel for greenhouse cooling with a 47 m horizontal, 56 cm nominal diameter U-bend buried galvanized ground heat exchanger. This system was designed and installed in the Solar Energy Institute, Ege University, Izmir, Turkey. Underground air tunnel systems, also known as earth-to-air heat exchangers, are recognized to be outstanding heating, cooling and air heating systems. On the other hand, they have not been used yet in the Turkish market. Greenhouses also have important economical potential in Turkey's agricultural sector. Greenhouses should be cooled during the summer or hot days. In order to establish optimum growth conditions in greenhouses, renewable energy sources should be utilized as much as possible. It is expected that effective use of underground air tunnels with a suitable technology in the modern greenhouses will play a leading role in Turkey in the foreseeable future. The exergy transports between the components and the destructions in each of the components of the system are determined for the average measured parameters obtained from the experimental results. Exergetic efficiencies of the system components are determined in an attempt to assess their individual performances and the potential for improvements is also presented. The daily maximum cooling coefficient of performances (COP) values for the system are also obtained to be 15.8. The total average COP in the experimental period is found to be 10.09. The system COP was calculated based on the amount of cooling produced by the air tunnel and the amount of power required to move the air through the tunnel, while the exergetic efficiency of the air tunnel is found to be in a range among 57.8-63.2%. The overall exergy efficiency value for the system on a product/fuel basis is found to be 60.7%. (author)

  7. Optimized mine ventilation on demand (OMVOD)

    International Nuclear Information System (INIS)

    Anderson, M.

    2009-01-01

    This paper provided an overview of the Optimized Mine Ventilation on Demand (OMVOD) system that is being installed at Xstrata Nickel Rim South Project and at Vale Inco's Totten Mine in Sudbury. The OMVOD system is designed to dynamically monitor and control air quality and quantity in real time and dilute and remove hazardous substances including diesel particulate matter (DPM), carbon monoxide (CO) and nitrous oxide (NO 2 ). It is also designed to control the thermal environment and provide ventilation for humans as well as mobile equipment engine combustion according to regulatory standards. The paper highlighted the OMVOD system optimization of energy, air quality measurement and control and production management of the mines through real time dynamic automation. Topics of discussion included real-time tracking and monitoring of diesel equipment; real-time tracking of underground miners; real-time evaluation of mine ventilation networks; and real-time control and optimization of ventilation equipment. ABB and Simsmart Technologies have joined forces to provide underground mining customers with a ventilation optimization solution. Simsmart's OMVOD provides proven real time/dynamic automation technology to significantly reduce energy costs, provide health and safety benefits as well as major capital cost savings while realizing an increase in production.

  8. Detecting Surface Changes from an Underground Explosion in Granite Using Unmanned Aerial System Photogrammetry

    Science.gov (United States)

    Schultz-Fellenz, Emily S.; Coppersmith, Ryan T.; Sussman, Aviva J.; Swanson, Erika M.; Cooley, James A.

    2017-08-01

    Efficient detection and high-fidelity quantification of surface changes resulting from underground activities are important national and global security efforts. In this investigation, a team performed field-based topographic characterization by gathering high-quality photographs at very low altitudes from an unmanned aerial system (UAS)-borne camera platform. The data collection occurred shortly before and after a controlled underground chemical explosion as part of the United States Department of Energy's Source Physics Experiments (SPE-5) series. The high-resolution overlapping photographs were used to create 3D photogrammetric models of the site, which then served to map changes in the landscape down to 1-cm-scale. Separate models were created for two areas, herein referred to as the test table grid region and the nearfield grid region. The test table grid includes the region within 40 m from surface ground zero, with photographs collected at a flight altitude of 8.5 m above ground level (AGL). The near-field grid area covered a broader area, 90-130 m from surface ground zero, and collected at a flight altitude of 22 m AGL. The photographs, processed using Agisoft Photoscan® in conjunction with 125 surveyed ground control point targets, yielded a 6-mm pixel-size digital elevation model (DEM) for the test table grid region. This provided the ≤3 cm resolution in the topographic data to map in fine detail a suite of features related to the underground explosion: uplift, subsidence, surface fractures, and morphological change detection. The near-field grid region data collection resulted in a 2-cm pixel-size DEM, enabling mapping of a broader range of features related to the explosion, including: uplift and subsidence, rock fall, and slope sloughing. This study represents one of the first works to constrain, both temporally and spatially, explosion-related surface damage using a UAS photogrammetric platform; these data will help to advance the science of

  9. Ventilating system for reprocessing of nuclear fuel rods

    International Nuclear Information System (INIS)

    Szulinski, M.J.

    1981-01-01

    In a nuclear facility such as a reprocessing plant for nuclear fuel rods, the central air cleaner discharging ventilating gas to the atmosphere must meet preselected standards not only as to the momentary concentration of radioactive components, but also as to total quantity per year. In order to comply more satisfactorily with such standards, reprocessing steps are conducted by remote control in a plurality of separate compartments. The air flow for each compartment is regulated so that the air inventory for each compartment has a slow turnover rate of more than a day but less than a year, which slow rate is conveniently designated as quasihermetic sealing. The air inventory in each such compartment is recirculated through a specialized processing unit adapted to cool and/or filter and/or otherwise process the gas. Stale air is withdrawn from such recirculating inventory and fresh air is injected (eg., By the less than perfect sealing of a compartment) into such recirculating inventory so that the air turnover rate is more than a day but less than a year. The amount of air directed through the manifold and duct system from the reprocessing units to the central air cleaner is less than in reprocessing plants of conventional design

  10. Tank Waste Remediation System Inactive Miscellaneous Underground Storage Tanks Program Plan

    International Nuclear Information System (INIS)

    Gustavson, R.D.

    1995-12-01

    The Program Management Plan (PMP) describes the approach that will be used to manage the Tank Waste Remediation System (TWRS) Inactive Miscellaneous Underground Storage Tank (IMUST) Program. The plan describes management, technical, and administrative control systems that will be used to plan and control the IMUSTs Program performance. The technical data to determine the IMUSTs status for inclusion in the Single Shell Tank Farm Controlled Clean and Stable (CCS) Program. The second is to identify and implement surveillance, characterization, stabilization, and modifications to support CCS prior to final closure

  11. The special improvement scheme for ventilation system of Caotaobei uranium mine and its implementation effect

    International Nuclear Information System (INIS)

    Wu Jianming; Du Yuhai; Shi Zuyuan

    2011-01-01

    The status of mine development, ventilation system and ventilation management in Caotaobei uranium mine is introduced, and problems existing in the ventilation system are pointed out, including enter-air pollution, air leaking, large air resistance. The special improvement scheme involved with technique and management are proposed for problems. After implementation of the scheme, the effective utilization of air volume has been greatly enhanced, and the allocation of air volume is reasonable. The acceptability rate of radon and its daughter concentrations has risen from 12.5% before implementation of the scheme to 88.9%. (authors)

  12. Upgrade of a transverse ventilation system in a bi-directional tunnel

    Directory of Open Access Journals (Sweden)

    Vidmar Peter

    2012-01-01

    Full Text Available The Karavanke tunnel forms an important link between Slovenia and Austria. The almost 8 km long tunnel is operated with bi-directional traffic and does not have dedicated escape routes. Moreover, the ventilation in case of fire does not satisfy requirements of the EU Directive 2004/54/EC that specifies the minimum requirements for tunnels in the trans-European road network. The paper present results of the research conducted regarding the possibility of upgrade the existing system in order to reach the required level of safety at lower costs possible. It is shown that with simple but novel adaptations of the ventilation system, a sizeable increase in the overall level of safety can be achieved. The methodology applied is a combination of a simple pipe model for tunnel ventilation and for detailed fluid dynamics analysis the CFD model is used. The existing ventilation system that in fire ventilation extracts smoke from a single duct is replaced with the smoke extraction from both ducts applying four axial fans. The analysis is focused on air/smoke flow through the vents and ducts and on pressure drops calculated over the length of the ventilation duct and its influence on the total flow. The change of the flow condition also has influence on ventilation fan operation point that is investigated in the paper as well.

  13. Association of ventilation system type with SBS symptoms in office workers

    Energy Technology Data Exchange (ETDEWEB)

    Seppanen, Olli; Fisk, William J.

    2001-02-07

    This paper provides a review and synthesis of current knowledge about the associations of ventilation system types in office buildings with sick building syndrome symptoms and discusses potential explanations for the associations. Relative to natural ventilation, air conditioning, with or without humidification, was consistently associated with a statistically significant increase in the prevalence of one or more SBS symptoms. Prevalences were typically higher by approximately 30% to 200% in the air conditioned buildings. In two of three assessments from a single study, symptom prevalences were also significantly higher in air conditioned buildings than in buildings with simple mechanical ventilation and no humidification. In approximately half of assessments, SBS symptom prevalences were significantly higher in buildings with simple mechanical ventilation than in buildings with natural ventilation. Insufficient information was available for conclusions about the potential increased risk of SBS symptoms with humidification. The statistically significant associations of mechanical ventilation and air conditioning with SBS symptoms are much more frequent than expected from chance and also not likely to be a consequence of confounding by several potential personal, job, or building related confounders. The reasons for the increases in symptom prevalences with mechanical ventilation and particularly with air conditioning remain unclear. Multiple deficiencies in HVAC system design, construction, operation, or maintenance, including some which cause pollutant emissions from HVAC systems, may contribute to the increases in symptom prevalences.

  14. A simulation Model of the Reactor Hall Ventilation and air Conditioning Systems of ETRR-2

    International Nuclear Information System (INIS)

    Abd El-Rahman, M.F.

    2004-01-01

    Although the conceptual design for any system differs from one designer to another. each of them aims to achieve the function of the system required. the ventilation and air conditioning system of reactors hall is one of those systems that really differs but always dose its function for which it is designed. thus, ventilation and air conditioning in some reactor hall constitute only one system whereas in some other ones, they are separate systems. the Egypt Research Reactor-2 (ETRR-2)represents the second type. most studies conducted on ventilation and air conditioning simulation models either in traditional building or for research rectors show that those models were not designed similarly to the model of the hall of ETRR-2 in which ventilation and air conditioning constitute two separate systems.besides, those studies experimented on ventilation and air conditioning simulation models of reactor building predict the temperature and humidity inside these buildings at certain outside condition and it is difficult to predict when the outside conditions are changed . also those studies do not discuss the influences of reactor power changes. therefore, the present work deals with a computational study backed by infield experimental measurements of the performance of the ventilation and air conditioning systems of reactor hall during normal operation at different outside conditions as well as at different levels of reactor power

  15. Muon flux measurements at the davis campus of the sanford underground research facility with the majorana demonstrator veto system

    Energy Technology Data Exchange (ETDEWEB)

    Abgrall, N.; Aguayo, E.; Avignone, F. T.; Barabash, A. S.; Bertrand, F. E.; Bradley, A. W.; Brudanin, V.; Busch, M.; Buuck, M.; Byram, D.; Caldwell, A. S.; Chan, Y-D.; Christofferson, C. D.; Chu, P. -H.; Cuesta, C.; Detwiler, J. A.; Dunagan, C.; Efremenko, Yu.; Ejiri, H.; Elliott, S. R.; Galindo-Uribarri, A.; Gilliss, T.; Giovanetti, G. K.; Goett, J.; Green, M. P.; Gruszko, J.; Guinn, I. S.; Guiseppe, V. E.; Henning, R.; Hoppe, E. W.; Howard, S.; Howe, M. A.; Jasinski, B. R.; Keeter, K. J.; Kidd, M. F.; Konovalov, S. I.; Kouzes, R. T.; LaFerriere, B. D.; Leon, J.; Lopez, A. M.; MacMullin, J.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Orrell, J. L.; O’Shaughnessy, C.; Overman, N. R.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Rielage, K.; Robertson, R. G. H.; Romero-Romero, E.; Ronquest, M. C.; Schmitt, C.; Shanks, B.; Shirchenko, M.; Snyder, N.; Suriano, A. M.; Tedeschi, D.; Trimble, J. E.; Varner, R. L.; Vasilyev, S.; Vetter, K.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, C. -H.; Yumatov, V.; Zhitnikov, I.

    2017-07-01

    We report the first measurement of the muon flux underground at the Davis Campus of the Sanford Underground Research Facility at the 4850 foot level. Measurements were done with the Majorana Demonstrator veto system arranged in two different configurations. Both results are in agreement within statistical accuracy. The measured flux is (4.08+-0.19) x 10 -9 muons/cm/2. We compare our results with previous calculations.

  16. Design of Mine Ventilators Monitoring System Based on Wireless Sensor Network

    Science.gov (United States)

    Fu, Sheng; Song, Haiqiang

    2012-05-01

    A monitoring system for a mine ventilator is designed based on ZigBee wireless sensor network technology in the paper. The system consists of a sink node, sensor nodes, industrial personal computer and several sensors. Sensor nodes communicate with the sink node through the ZigBee wireless sensor network. The sink node connects with the configuration software on the pc via serial port. The system can collect or calculate vibration, temperature, negative pressure, air volume and other information of the mine ventilator. Meanwhile the system accurately monitors operating condition of the ventilator through these parameters. Especially it provides the most original information for potential faults of the ventilator. Therefore, there is no doubt that it improves the efficiency of fault diagnosis.

  17. Design of Mine Ventilators Monitoring System Based on Wireless Sensor Network

    International Nuclear Information System (INIS)

    Fu Sheng; Song Haiqiang

    2012-01-01

    A monitoring system for a mine ventilator is designed based on ZigBee wireless sensor network technology in the paper. The system consists of a sink node, sensor nodes, industrial personal computer and several sensors. Sensor nodes communicate with the sink node through the ZigBee wireless sensor network. The sink node connects with the configuration software on the pc via serial port. The system can collect or calculate vibration, temperature, negative pressure, air volume and other information of the mine ventilator. Meanwhile the system accurately monitors operating condition of the ventilator through these parameters. Especially it provides the most original information for potential faults of the ventilator. Therefore, there is no doubt that it improves the efficiency of fault diagnosis.

  18. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT: NEW CONDENSATOR, INC.--THE CONDENSATOR DIESEL ENGINE RETROFIT CRANKCASE VENTILATION SYSTEM

    Science.gov (United States)

    EPA's Environmental Technology Verification Program has tested New Condensator Inc.'s Condensator Diesel Engine Retrofit Crankcase Ventilation System. Brake specific fuel consumption (BSFC), the ratio of engine fuel consumption to the engine power output, was evaluated for engine...

  19. Study on pollution control in residential kitchen based on the push-pull ventilation system

    DEFF Research Database (Denmark)

    Zhou, Bin; Chen, Feng; Dong, Zhibo

    2016-01-01

    Highlights •The push-pull ventilation system is proposed to improve IAQ inside kitchen, where air is supplied through slot air curtain and then exhausted through range hood. •CO2 reduction efficiency with application of air curtain in experiment and simulation in breathing zone was 23.7% and 23.......1%, respectively. •By orthogonal method, the influence of factors on pollution control of the push-pull ventilation system was presented....

  20. Indoor temperatures for calculating room heat loss and heating capacity of radiant heating systems combined with mechanical ventilation systems

    DEFF Research Database (Denmark)

    Wu, Xiaozhou; Olesen, Bjarne W.; Fang, Lei

    2016-01-01

    In this study, a typical office room with a radiant heating system and a mechanical ventilation system was selected as the research subject. Indoor temperature formulas for calculating the room heat loss (including transmission heat loss and ventilation heat loss) and heating capacity of the hybrid...... for calculating ventilation heat loss and heating capacity of radiant heating systems combined with mechanical ventilation systems. (C) 2015 Elsevier B.V. All rights reserved....... change rates on the indoor temperatures were performed using the proposed model. When heated surface temperatures and air change rates were from 21.0 to 29.0 degrees C and from 0.5 to 4.0 h-1, the indoor temperatures for calculating the transmission heat loss and ventilation heat loss were between 20...

  1. Waste tank ventilation rates measured with a tracer gas method

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Evans, J.C.; Sklarew, D.S.; Mitroshkov, A.V.

    1998-08-01

    Passive ventilation with the atmosphere is used to prevent accumulation of waste gases and vapors in the headspaces of 132 of the 177 high-level radioactive waste Tanks at the Hanford Site in Southeastern Washington State. Measurements of the passive ventilation rates are needed for the resolution of two key safety issues associated with the rates of flammable gas production and accumulation and the rates at which organic salt-nitrate salt mixtures dry out. Direct measurement of passive ventilation rates using mass flow meters is not feasible because ventilation occurs va multiple pathways to the atmosphere (i.e., via the filtered breather riser and unsealed tank risers and pits), as well as via underground connections to other tanks, junction boxes, and inactive ventilation systems. The tracer gas method discussed in this report provides a direct measurement of the rate at which gases are removed by ventilation and an indirect measurement of the ventilation rate. The tracer gas behaves as a surrogate of the waste-generated gases, but it is only diminished via ventilation, whereas the waste gases are continuously released by the waste and may be subject to depletion mechanisms other than ventilation. The fiscal year 1998 tracer studies provide new evidence that significant exchange of air occurs between tanks via the underground cascade pipes. Most of the single-shell waste tanks are connected via 7.6-cm diameter cascade pipes to one or two adjacent tanks. Tracer gas studies of the Tank U-102/U-103 system indicated that the ventilation occurring via the cascade line could be a significant fraction of the total ventilation. In this two-tank cascade, air evidently flowed from Tank U-103 to Tank U-102 for a time and then was observed to flow from Tank U-102 to Tank U-103

  2. A GIS Based 3D Online Decision Assistance System for Underground Energy Storage in Northern Germany

    Science.gov (United States)

    Nolde, M.; Schwanebeck, M.; Biniyaz, E.; Duttmann, R.

    2014-12-01

    We would like to present a GIS-based 3D online decision assistance system for underground energy storage. Its aim is to support the local land use planning authorities through pre-selection of possible sites for thermal, electrical and substantial underground energy storages. Since the extension of renewable energies has become legal requirement in Germany, the underground storing of superfluously produced green energy (such as during a heavy wind event) in the form of compressed air, gas or heated water has become increasingly important. However, the selection of suitable sites is a complex task. The assistance system uses data of geological features such as rock layers, salt caverns and faults enriched with attribute data such as rock porosity and permeability. This information is combined with surface data of the existing energy infrastructure, such as locations of wind and biogas stations, power line arrangement and cable capacity, and energy distribution stations. Furthermore, legal obligations such as protected areas on the surface and current underground mining permissions are used for the decision finding process. Not only the current situation but also prospective scenarios, such as expected growth in produced amount of energy are incorporated in the system. The decision process is carried out via the 'Analytic Hierarchy Process' (AHP) methodology of the 'Multi Object Decision Making' (MODM) approach. While the process itself is completely automated, the user has full control of the weighting of the different factors via the web interface. The system is implemented as an online 3D server GIS environment, with no software needed to be installed on the user side. The results are visualized as interactive 3d graphics. The implementation of the assistance system is based exclusively on free and open source software, and utilizes the 'Python' programming language in combination with current web technologies, such as 'HTML5', 'CSS3' and 'JavaScript'. It is

  3. Radon Monitoring and Early Low Background Counting at the Sanford Underground Laboratory

    International Nuclear Information System (INIS)

    Thomas, K. J.; Mei, D.-M.; Heise, J.; Durben, D.; Salve, R.

    2011-01-01

    Radon detectors have been deployed underground at the Sanford Underground Laboratory at the site of the former Homestake Mine in Lead, SD. Currently, no radon mitigation measures are in place in the underground environment, and the continuing evolution of the facility ventilation systems has led to significant variations in early airborne radon concentrations. The average radon concentration measured near the primary ventilation intake for the 4850-ft level (Yates shaft) is 391 Bq/m 3 , based on approximately 146 days of data. The corresponding average radon concentration near the other main ventilation intake for the 4850-ft level (Ross shaft) is 440 Bq/m 3 based on approximately 350 days of data. Measurements have also been collected near the 1250-ft level Ross shaft, with average radon concentrations at 180 Bq/m 3 . Secondary factors that may increase the baseline radon level underground include the presence of iron oxide and moisture, which are known to enhance radon emanation. The results of the current radon monitoring program will be used for the planning of future measurements and any potential optimization of ventilation parameters for the reduction of radon in relevant areas underground.

  4. Radon monitoring and early low background counting at the Sanford Underground Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, K.J.; Mei, D.M.; Heise, J.; Durben, D.; Salve, R.

    2010-09-01

    Radon detectors have been deployed underground at the Sanford Underground Laboratory at the site of the former Homestake Mine in Lead, SD. Currently, no radon mitigation measures are in place in the underground environment, and the continuing evolution of the facility ventilation systems has led to significant variations in early airborne radon concentrations. The average radon concentration measured near the primary ventilation intake for the 4850-ft level (Yates shaft) is 391 Bq/m{sup 3}, based on approximately 146 days of data. The corresponding average radon concentration near the other main ventilation intake for the 4850-ft level (Ross shaft) is 440 Bq/m{sup 3} based on approximately 350 days of data. Measurements have also been collected near the 1250-ft level Ross shaft, with average radon concentrations at 180 Bq/m{sup 3}. Secondary factors that may increase the baseline radon level underground include the presence of iron oxide and moisture, which are known to enhance radon emanation. The results of the current radon monitoring program will be used for the planning of future measurements and any potential optimization of ventilation parameters for the reduction of radon in relevant areas underground.

  5. Indoor radon in three similar two-story houses with different ventilation systems

    International Nuclear Information System (INIS)

    Kokotti, H.; Savolainen, T.; Raunemaa, T.; Kalliokoski, P.

    1989-01-01

    Radon levels were monitored in three similar two-story apartment houses which were located side by side on a gravel esker in eastern Finland. The houses differed only in regard to their ventilation systems which included the following: natural ventilation, mechanical exhaust, and complete mechanical ventilation. The study started immediately when the houses were finished and was continued for two years. Radon concentrations were highest (60-430 Bq/m 3 ) in the beginning of the study period before the tenants moved in. During the following spring and fall, average radon levels of the houses decreased below 100 Bq/m 3 . Radon concentrations varied within a wide range, from 20 to 230 Bq/m 3 , in the apartments. Among the houses, the highest concentrations were found in the house equipped with mechanical exhaust ventilation and the lowest in the house with both a mechanical supply and exhaust system. One reason for the decreasing levels of radon after a one-year occupancy was that the tenants increased the ventilation of their apartments. In the house with complete mechanical ventilation, the stability of ventilation also contributed to the decrease of the indoor radon level

  6. Extended investigation into continuous laser scanning of underground mine workings by means of Landis inertial navigation system

    Science.gov (United States)

    Belyaev, E. N.

    2017-10-01

    The paper investigates the method of applying mobile scanning systems (MSSs) with inertial navigators in the underground conditions for carrying out the surveying tasks. The available mobile laser scanning systems cannot be used in the underground environment since Global Positioning System (GPS) signals cannot be received in mines. This signal not only is necessary for space positioning, but also operates as the main corrective signal for the primary navigation system - the inertial navigation system. The idea of the method described in this paper consists in using MSSs with a different correction of the inertial system than GPS is.

  7. Technologies to apply optic fibers to an underground cable system; Chichu cable system eno hikari fiber oyo gijutsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-10

    Discussions were given for the purpose of realizing automation of facility operation and automatic monitoring of facilities by using optical electronics technologies in underground power transmission facilities. In sensing technologies using optic fibers, an optic fiber distribution type sensor was found suitable for monitoring underground power transmission lines as a sensor to measure temperature distribution and pressure distribution along the optic fibers. In sensor signal transmission technologies using optic fibers, laying ultra-high voltage transmission lines over a distance of several ten kilometers is becoming used generally in underground transmission paths, with the environmental requirements on electromagnetic fields becoming more stringent. Under these restraints, an optical transmission system is more advantageous that has longer-distance and wider-area transmission capabilities, and high-insulation and non-induction performances. In technologies to lay optic fiber cables in underground cable paths, contrivances are given on the cable construction for cases where optic fibers and power cables, each varying in mechanical strength are to be integrated. 151 refs., 155 figs., 30 tabs.

  8. Underground mine navigation using an integrated IMU/TOF system with unscented Kalman filter

    CSIR Research Space (South Africa)

    Hlophe, K

    2011-07-01

    Full Text Available Page 1 of 11 26th International Conference of CAD/CAM, Robotics & Factories of the Future Conference, 26-28 July 2011, Kuala Lumpur, Malaysia UNDERGROUND MINE NAVIGATION USING AN INTERGRATED IMU/TOF SYSTEM WITH UNSCENTED KALMAN FILTER... Page 2 of 11 26th International Conference of CAD/CAM, Robotics & Factories of the Future Conference, 26-28 July 2011, Kuala Lumpur, Malaysia Zhang et al [4] introduced a new set of general dynamic models of IMU to describe the state of a...

  9. The development of WIPPVENT, a windows based interactive mine ventilation simulation software program at the Waste Isolation Pilot Plant

    International Nuclear Information System (INIS)

    McDaniel, K.H.

    1995-01-01

    An interactive mine ventilation simulation software program (WIPPVENT) was developed at the Waste Isolation Pilot Plant (WIPP). The WIPP is a US Department of Energy (DOE) research and development project located near Carlsbad, New Mexico. The facility is designed to provide a permanent, safe underground disposal of US defense generated transuranic waste in bedded salt. In addition to it's regular functions, the underground ventilation system is engineered to prevent the uncontrolled spread of radioactive materials in the unlikely event of a release. To enhance the operability system, Westinghouse Electric Corporation has developed an interactive mine ventilation simulation software program (WIPPVENT). While WIPPVENT includes most of the functions of the commercially available simulation program VNETPC (copyright 1991 Mine Ventilation Services, Inc.), the user interface has been completely rewritten as a Windows reg-sign application and screen graphics have been added. WIPPVENT is designed to interact with the WIPP ventilation monitoring systems through the site wide Central Monitoring System

  10. Use of perforated acoustic panels as supply air diffusers in diffuse ceiling ventilation systems

    DEFF Research Database (Denmark)

    Iqbal, Ahsan; Kazemi, Seyed Hossein; Ardkapan, Siamak Rahimi

    Ventilation is needed for diluting and removing the contaminants, odour and excess heat from the building interior. It is important that the inhabitants perceive the ventilated spaces as comfortable. Therefore, the supply air should reach all parts of the occupied zones. Troldtekt has been...... manufacturing perforated acoustic panels for the last 13 years. The panels can be used not only in applications related to acoustics but also as low pressure drop supply air diffusers, particularly in diffuse ceiling ventilation systems. The present study verifies on a theoretically level the performance...

  11. Change-over natural and mechanical ventilation system energy consumption in single-family buildings

    Science.gov (United States)

    Kostka, Maria; Szulgowska-Zgrzywa, Małgorzata

    2017-11-01

    The parameters of the outside air in Poland cause that in winter it is reasonable to use a mechanical ventilation equipped with a heat recovery exchanger. The time of spring, autumn, summer evenings and nights are often characterized by the parameters of the air, which allow for a natural ventilation and reduce the electricity consumption. The article presents the possibilities of energy consumption reduction for three energy standards of buildings located in Poland, ventilated by a change-over hybrid system. The analysis was prepared on the assumption that the air-to-water heat pump is the heat source for the buildings.

  12. Influence of Radon Radionuclide for the Development of an Ultra-Low Background Gamma Spectrometer in an Underground Research Tunnel

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Wanno; Choi, Sangdo; Kim, Kyungsoo; Kang, Munja; Choi, Geunsik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    Installation in an underground level is very good to reduce the background induced by cosmic rays. A system in a surface laboratory is difficult to achieve enough reduction of the background, and an underground system has one main disadvantage in that researchers or workers are inconvenienced in accessing from office to laboratory, even though the background reduction is enough. KAERI (Korea Atomic Energy Research Institute) has performed ultra low-level background spectrometry using an active and passive shield at a surface laboratory. Based on our research experience of ultra-low level background system at a surface laboratory for many years, an underground gamma-ray spectrometry system is more effective for background reduction, but convenient access to an underground laboratory should be considered. The KAERI Underground Research Tunnel (KURT) is an infrastructure for a validation of the high-level waste disposal technology, which is located at a small mountain of KAERI. The geology of this mountain is composed primarily of granite. The ultra-low background system with passive and active shielding at KURT is developed, which is located underground with 156 m of water-equivalent below a surface level. Here, the influence of radon radionuclide is studied to test the performance of the developed system. Firstly, the background increase by radon radionuclide is examined, and secondly, a radiological dose assessment via radon radionuclides is evaluated. Underground radon concentration of day time with ventilation is similar with that of a ground laboratory. Therefore the background increase by radon will be solved using ventilation. Extra dose exposure by radon can be negligible in the day but time without ventilation has some problems. So the ventilation system for the experiment period in underground laboratory should be operated in order to protect extra dose exposure.

  13. Influence of Radon Radionuclide for the Development of an Ultra-Low Background Gamma Spectrometer in an Underground Research Tunnel

    International Nuclear Information System (INIS)

    Lee, Wanno; Choi, Sangdo; Kim, Kyungsoo; Kang, Munja; Choi, Geunsik

    2013-01-01

    Installation in an underground level is very good to reduce the background induced by cosmic rays. A system in a surface laboratory is difficult to achieve enough reduction of the background, and an underground system has one main disadvantage in that researchers or workers are inconvenienced in accessing from office to laboratory, even though the background reduction is enough. KAERI (Korea Atomic Energy Research Institute) has performed ultra low-level background spectrometry using an active and passive shield at a surface laboratory. Based on our research experience of ultra-low level background system at a surface laboratory for many years, an underground gamma-ray spectrometry system is more effective for background reduction, but convenient access to an underground laboratory should be considered. The KAERI Underground Research Tunnel (KURT) is an infrastructure for a validation of the high-level waste disposal technology, which is located at a small mountain of KAERI. The geology of this mountain is composed primarily of granite. The ultra-low background system with passive and active shielding at KURT is developed, which is located underground with 156 m of water-equivalent below a surface level. Here, the influence of radon radionuclide is studied to test the performance of the developed system. Firstly, the background increase by radon radionuclide is examined, and secondly, a radiological dose assessment via radon radionuclides is evaluated. Underground radon concentration of day time with ventilation is similar with that of a ground laboratory. Therefore the background increase by radon will be solved using ventilation. Extra dose exposure by radon can be negligible in the day but time without ventilation has some problems. So the ventilation system for the experiment period in underground laboratory should be operated in order to protect extra dose exposure

  14. Clinical assessment of a commercial delivery system for aerosol ventilation scanning by comparison with Krypton-81m

    International Nuclear Information System (INIS)

    Wollmer, P.; Eriksson, L.; Andersson, A.

    1985-01-01

    A commercial aerosol delivery system for ventilation scanning was evaluated in 23 patients with lung disease involving regional disturbances of ventilation. Ventilation scans obtained after inhalation of an aerosol labeled with In-113m were compared with Kr-81m ventilation scans. An indirect comparison was also made with a settling bag technique. There was close agreement between the aerosol and the Kr-81m ventilation scans in all of the patients. The aerosol outlined the ventilated parts of the lung adequately, and central deposition of particles was minimal. The penetration of the aerosol into the lung was higher with the delivery system that with a settling bag system. The aerosol delivery system appears suitable for clinical pulmonary ventilation scintigraphy

  15. Ventilation system type, classroom environmental quality and pupils' perceptions and symptoms

    DEFF Research Database (Denmark)

    Gao, Jie; Wargocki, Pawel; Wang, Yi

    2014-01-01

    -heating and heating seasons; CO2 concentration was used to estimate average classroom ventilation rates. At the end of each measuring period, the pupils were asked to report their perceptions of the indoor environment and their acute health-related symptoms. The classroom in which ventilation was achieved by manually...... opened in all four classrooms in the non-heating season but very seldom in the heating season. Automatic operation of the windows had a marked effect on CO2 concentration and classroom temperature in the heating season. Perceptions of the indoor environment were more positive in the classroom...... that was ventilated by automatically operable windows with an exhaust fan in operation: fewer symptoms were reported in this classroom compared with classrooms with other systems. Present results and approach can be used as the basis for rational selection of systems that ensure adequate classroom ventilation. © 2014...

  16. Ventilation systems as an effective tool for control of radon daughter concentration in mines

    International Nuclear Information System (INIS)

    Dory, A.B.

    1981-10-01

    Introduced with a brief discussion of the key role of ventilation in controlling mine atmospheres, the effects of the design of the ventilation system on the control of radon daughter concentrations are illustrated with specific reference to Alcan's Director Mine, St-Lawrence, Nfld. (This fluorspar mine was found to have high radon concentrations due to mine water bringing in dissolved radon.) After a discussion of the health physics history of the mine, the various phases of the ventilation system design and the general results are detailed. The author draws some conclusions having general application to the design of any mine with a radon or thoron daughter concentration. These include minimizing the 'age' of the air; the need for continuous ventilation in all areas; the value of remote control and monitoring; and the benefits of mine pressurization

  17. Ventilation patterns of the songbird lung/air sac system during different behaviors.

    Science.gov (United States)

    Mackelprang, Rebecca; Goller, Franz

    2013-10-01

    Unidirectional, continuous airflow through the avian lung is achieved through an elaborate air sac system with a sequential, posterior to anterior ventilation pattern. This classical model was established through various approaches spanning passively ventilated systems to mass spectrometry analysis of tracer gas flow into various air sacs during spontaneous breathing in restrained ducks. Information on flow patterns in other bird taxa is missing, and these techniques do not permit direct tests of whether the basic flow pattern can change during different behaviors. Here we use thermistors implanted into various locations of the respiratory system to detect small pulses of tracer gas (helium) to reconstruct airflow patterns in quietly breathing and behaving (calling, wing flapping) songbirds (zebra finch and yellow-headed blackbird). The results illustrate that the basic pattern of airflow in these two species is largely consistent with the model. However, two notable differences emerged. First, some tracer gas arrived in the anterior set of air sacs during the inspiration during which it was inhaled, suggesting a more rapid throughput through the lung than previously assumed. Second, differences in ventilation between the two anterior air sacs emerged during calling and wing flapping, indicating that adjustments in the flow pattern occur during dynamic behaviors. It is unclear whether this modulation in ventilation pattern is passive or active. This technique for studying ventilation patterns during dynamic behaviors proves useful for establishing detailed timing of airflow and modulation of ventilation in the avian respiratory system.

  18. A new system for continuous and remote monitoring of patients receiving home mechanical ventilation.

    Science.gov (United States)

    Battista, L

    2016-09-01

    Home mechanical ventilation is the treatment of patients with respiratory failure or insufficiency by means of a mechanical ventilator at a patient's home. In order to allow remote patient monitoring, several tele-monitoring systems have been introduced in the last few years. However, most of them usually do not allow real-time services, as they have their own proprietary communication protocol implemented and some ventilation parameters are not always measured. Moreover, they monitor only some breaths during the whole day, despite the fact that a patient's respiratory state may change continuously during the day. In order to reduce the above drawbacks, this work reports the development of a novel remote monitoring system for long-term, home-based ventilation therapy; the proposed system allows for continuous monitoring of the main physical quantities involved during home-care ventilation (e.g., differential pressure, volume, and air flow rate) and is developed in order to allow observations of different remote therapy units located in different places of a city, region, or country. The developed remote patient monitoring system is able to detect various clinical events (e.g., events of tube disconnection and sleep apnea events) and has been successfully tested by means of experimental tests carried out with pulmonary ventilators typically used to support sick patients.

  19. A new system for continuous and remote monitoring of patients receiving home mechanical ventilation

    Science.gov (United States)

    Battista, L.

    2016-09-01

    Home mechanical ventilation is the treatment of patients with respiratory failure or insufficiency by means of a mechanical ventilator at a patient's home. In order to allow remote patient monitoring, several tele-monitoring systems have been introduced in the last few years. However, most of them usually do not allow real-time services, as they have their own proprietary communication protocol implemented and some ventilation parameters are not always measured. Moreover, they monitor only some breaths during the whole day, despite the fact that a patient's respiratory state may change continuously during the day. In order to reduce the above drawbacks, this work reports the development of a novel remote monitoring system for long-term, home-based ventilation therapy; the proposed system allows for continuous monitoring of the main physical quantities involved during home-care ventilation (e.g., differential pressure, volume, and air flow rate) and is developed in order to allow observations of different remote therapy units located in different places of a city, region, or country. The developed remote patient monitoring system is able to detect various clinical events (e.g., events of tube disconnection and sleep apnea events) and has been successfully tested by means of experimental tests carried out with pulmonary ventilators typically used to support sick patients.

  20. Ventilation Model

    International Nuclear Information System (INIS)

    Yang, H.

    1999-01-01

    The purpose of this analysis and model report (AMR) for the Ventilation Model is to analyze the effects of pre-closure continuous ventilation in the Engineered Barrier System (EBS) emplacement drifts and provide heat removal data to support EBS design. It will also provide input data (initial conditions, and time varying boundary conditions) for the EBS post-closure performance assessment and the EBS Water Distribution and Removal Process Model. The objective of the analysis is to develop, describe, and apply calculation methods and models that can be used to predict thermal conditions within emplacement drifts under forced ventilation during the pre-closure period. The scope of this analysis includes: (1) Provide a general description of effects and heat transfer process of emplacement drift ventilation. (2) Develop a modeling approach to simulate the impacts of pre-closure ventilation on the thermal conditions in emplacement drifts. (3) Identify and document inputs to be used for modeling emplacement ventilation. (4) Perform calculations of temperatures and heat removal in the emplacement drift. (5) Address general considerations of the effect of water/moisture removal by ventilation on the repository thermal conditions. The numerical modeling in this document will be limited to heat-only modeling and calculations. Only a preliminary assessment of the heat/moisture ventilation effects and modeling method will be performed in this revision. Modeling of moisture effects on heat removal and emplacement drift temperature may be performed in the future

  1. Optimized ventilation-on-demand (VOD)

    Energy Technology Data Exchange (ETDEWEB)

    Masse, M. [Simsmart Technologies Inc., Brossard, PQ (Canada); Cervinka, A. [Newtrax Technologies Inc., Montreal, PQ (Canada)

    2008-07-01

    This presentation described how the combination of 2 innovative technologies can help optimize mine ventilation. Newtrax Technologies has developed a self-contained battery-powered wireless electronic system designed to operate in harsh industrial environments, including underground mines. Simsmart Technologies has created an advanced process and control simulation based design tool used in industrial applications, including mine ventilation systems. This presentation described the system components and how they work. These included the wireless mesh network designed for dynamic diesel machinery tracking and operating status monitoring; the real-time ventilation model and fan speed optimizer; the OPC server for information interchange; the OPC linkage to existing control infrastructure; a human machine interface that provide data archiving capability; live MS-Excel to interrogate the simulation, controls and optimizer; and, the battery-powered network mesh that provides SCADA functionality to route optimized setpoints. Details of the user interface were also provided. 1 tab., 20 figs.

  2. Alternatives generation and analysis for double-shell tank primary ventilation systems emissions control and monitoring

    International Nuclear Information System (INIS)

    SEDERBURG, J.P.

    1999-01-01

    This AGA addresses the question: ''What equipment upgrades, operational changes, and/or other actions are required relative to the DST tanks farms' ventilation systems to support retrieval, staging (including feed sampling), and delivery of tank waste to the Phase I private contractor?'' Issues and options for the various components within the ventilation subsystem affect each other. Recommended design requirements are presented and the preferred alternatives are detailed

  3. Alternatives generation and analysis for double-shell tank primary ventilation systems emissions control and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    SEDERBURG, J.P.

    1999-09-30

    This AGA addresses the question: ''What equipment upgrades, operational changes, and/or other actions are required relative to the DST tanks farms' ventilation systems to support retrieval, staging (including feed sampling), and delivery of tank waste to the Phase I private contractor?'' Issues and options for the various components within the ventilation subsystem affect each other. Recommended design requirements are presented and the preferred alternatives are detailed.

  4. Test Protocol for Room-to-Room Distribution of Outside Air by Residential Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Barley, C. D.; Anderson, R.; Hendron, B.; Hancock, E.

    2007-12-01

    This test and analysis protocol has been developed as a practical approach for measuring outside air distribution in homes. It has been used successfully in field tests and has led to significant insights on ventilation design issues. Performance advantages of more sophisticated ventilation systems over simpler, less-costly designs have been verified, and specific problems, such as airflow short-circuiting, have been identified.

  5. Study of the predominant defect development in rails of underground systems after preventive grinding and lubrication

    Directory of Open Access Journals (Sweden)

    Voronin Serhii

    2017-01-01

    Full Text Available In order to determine the method of contact surface treatment and to define the rational surface roughness in the wheel/rail contact for the minimal growth rate of contact fatigue defects the program of experiments in operational conditions was developed. On the basis of the results and calculations the coefficients of regression equations, which describe dependencies of the wear rate on the parameters of the contact surface treatment in real operational conditions were obtained. Besides, the diagrams of dependencies of the friction coefficient on the roughness of railhead contact surface of the high rails with and without lubrication, when laid in curves of underground systems, were built. The experiments conducted in operational conditions of Kharkiv Metro revealed the influence of roughness of the railhead side surface of the high rails in curves on the contact fatigue defect development after preventive grinding and lubrication. According to the results of the experiments it was established that the rail preventive grinding with simultaneous lubrication led to slower contact fatigue defect development in rails of underground systems. The rational roughness of the railhead side surface of the high rails in curves after preventive grinding, which led to the minimal rate of defect development, was defined.

  6. ASSESSMENT of POTENTIAL CARBON DIOXIDE-BASED DEMAND CONTROL VENTILATION SYSTEM PERFORMANCE in SINGLE ZONE SYSTEMS

    Science.gov (United States)

    2013-03-21

    requirements of a 400 m3 space in a multiuse facility in South Korea using two types of DCV systems—one CO2-based and the other uses a radio frequency...identification (RFID) device to detect zone occupancy 25 (Jeong et al., 2010). A dedicated outdoor air system supplies ventilation air to the zone...use a known control scheme (ASHRAE, 2010b). Carbon Dioxide Sensor Modeling Case Study 2 While the first case study examines a single multiuse

  7. Chemical Characterisation of the Coarse and Fine Particulate Matter in the Environment of an Underground Railway System: Cytotoxic Effects and Oxidative Stress?A Preliminary Study

    OpenAIRE

    Spagnolo, Anna Maria; Ottria, Gianluca; Perdelli, Fernanda; Cristina, Maria Luisa

    2015-01-01

    Background: Exposure to the particulate matter produced in underground railway systems is arousing increasing scientific interest because of its health effects. The aim of our study was to evaluate the airborne concentrations of PM10 and three sub-fractions of PM2.5 in an underground railway system environment in proximity to platforms and in underground commercial areas within the system, and to compare these with the outdoor airborne concentrations. We also evaluated the metal components, ...

  8. VENTILATION NEEDS DURING CONSTRUCTION

    International Nuclear Information System (INIS)

    C.R. Gorrell

    1998-01-01

    The purpose of this analysis is to determine ventilation needs during construction and development of the subsurface repository and develop systems to satisfy those needs. For this analysis, construction is defined as pre-emplacement excavation and development is excavation that takes place simultaneously with emplacement. The three options presented in the ''Overall Development and Emplacement Ventilation Systems'' analysis (Reference 5.5) for development ventilation will be applied to construction ventilation in this analysis as well as adding new and updated ventilation factors to each option for both construction and development. The objective of this analysis is to develop a preferred ventilation system to support License Application Design. The scope of this analysis includes: (1) Description of ventilation conditions; (2) Ventilation factors (fire hazards, dust control, construction logistics, and monitoring and control systems); (3) Local ventilation alternatives; (4) Global ventilation options; and (5) Evaluation of options

  9. Performance evaluation of a novel personalized ventilation-personalized exhaust system for airborne infection control.

    Science.gov (United States)

    Yang, J; Sekhar, S C; Cheong, K W D; Raphael, B

    2015-04-01

    In the context of airborne infection control, it is critical that the ventilation system is able to extract the contaminated exhaled air within the shortest possible time. To minimize the spread of contaminated air exhaled by occupants efficiently, a novel personalized ventilation (PV)-personalized exhaust (PE) system has been developed, which aims to exhaust the exhaled air as much as possible from around the infected person (IP). The PV-PE system was studied experimentally for a particular healthcare setting based on a typical consultation room geometry and four different medical consultation positions of an IP and a healthy person (HP). Experiments using two types of tracer gases were conducted to evaluate two types of PE: Top-PE and Shoulder-PE under two different background ventilation systems: Mixing Ventilation and Displacement Ventilation. Personalized exposure effectiveness, intake fraction (iF) and exposure reduction (ε) were used as indices to evaluate the PV-PE system. The results show that the combined PV-PE system for the HP achieves the lowest intake fraction; and the use of PE system for the IP alone shows much better performance than using PV system for the HP alone. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. 30 CFR 75.340 - Underground electrical installations.

    Science.gov (United States)

    2010-07-01

    ... Section 75.340 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.340 Underground...) Ventilated with intake air that is monitored for carbon monoxide or smoke by an AMS installed and operated...

  11. Assessment of the impact of dipped guideways on urban rail transit systems: Ventilation and safety requirements

    Science.gov (United States)

    1982-01-01

    The ventilation and fire safety requirements for subway tunnels with dipped profiles between stations as compared to subway tunnels with level profiles were evaluated. This evaluation is based upon computer simulations of a train fire emergency condition. Each of the tunnel configurations evaluated was developed from characteristics that are representative of modern transit systems. The results of the study indicate that: (1) The level tunnel system required about 10% more station cooling than dipped tunnel systems in order to meet design requirements; and (2) The emergency ventilation requirements are greater with dipped tunnel systems than with level tunnel systems.

  12. Design Principles for Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per

    For many years mechanical and natural ventilation systems have developed separately. Naturally, the next step in this development is the development of ventilation concepts that utilize and combine the best features from each system to create a new type of ventilation system -Hybrid Ventilation. ....... The hybrid ventilation concepts, design challenges and - principles are discussed and illustrated by four building examples....

  13. Horonobe Underground Research Laboratory project. Overview of the pilot borehole investigation of the ventilation shaft (PB-V01). Geological investigation

    International Nuclear Information System (INIS)

    Funaki, Hironori; Tokiwa, Tetsuya; Ishii, Eiichi; Hatsuyama, Yoshihiro; Matsuo, Shigeaki; Tsuda, Kazuyasu; Koizumi, Akira; Ishikawa, Taiki; Daijo, Yuichi; Sugiyama, Kazutoshi

    2008-08-01

    We conducted geological investigation of the pilot borehole of the ventilation shaft in Horonobe from October 2007 to March 2008. This report describes the field operations (core description, core photograph, and core sampling) and laboratory measurements (modal analysis and X-ray diffraction analysis), equipments as well as processing procedures, and shows the obtained results. The information obtained from the investigation will be reflected in spring water control plan on shaft excavation and additional plan of drainage treatment facilities. A CD-ROM is attached as an appendix (J.P.N.)

  14. An Integrated Environment Monitoring System for Underground Coal Mines—Wireless Sensor Network Subsystem with Multi-Parameter Monitoring

    Science.gov (United States)

    Zhang, Yu; Yang, Wei; Han, Dongsheng; Kim, Young-Il

    2014-01-01

    Environment monitoring is important for the safety of underground coal mine production, and it is also an important application of Wireless Sensor Networks (WSNs). We put forward an integrated environment monitoring system for underground coal mine, which uses the existing Cable Monitoring System (CMS) as the main body and the WSN with multi-parameter monitoring as the supplementary technique. As CMS techniques are mature, this paper mainly focuses on the WSN and the interconnection between the WSN and the CMS. In order to implement the WSN for underground coal mines, two work modes are designed: periodic inspection and interrupt service; the relevant supporting technologies, such as routing mechanism, collision avoidance, data aggregation, interconnection with the CMS, etc., are proposed and analyzed. As WSN nodes are limited in energy supply, calculation and processing power, an integrated network management scheme is designed in four aspects, i.e., topology management, location management, energy management and fault management. Experiments were carried out both in a laboratory and in a real underground coal mine. The test results indicate that the proposed integrated environment monitoring system for underground coal mines is feasible and all designs performed well as expected. PMID:25051037

  15. An integrated environment monitoring system for underground coal mines--Wireless Sensor Network subsystem with multi-parameter monitoring.

    Science.gov (United States)

    Zhang, Yu; Yang, Wei; Han, Dongsheng; Kim, Young-Il

    2014-07-21

    Environment monitoring is important for the safety of underground coal mine production, and it is also an important application of Wireless Sensor Networks (WSNs). We put forward an integrated environment monitoring system for underground coal mine, which uses the existing Cable Monitoring System (CMS) as the main body and the WSN with multi-parameter monitoring as the supplementary technique. As CMS techniques are mature, this paper mainly focuses on the WSN and the interconnection between the WSN and the CMS. In order to implement the WSN for underground coal mines, two work modes are designed: periodic inspection and interrupt service; the relevant supporting technologies, such as routing mechanism, collision avoidance, data aggregation, interconnection with the CMS, etc., are proposed and analyzed. As WSN nodes are limited in energy supply, calculation and processing power, an integrated network management scheme is designed in four aspects, i.e., topology management, location management, energy management and fault management. Experiments were carried out both in a laboratory and in a real underground coal mine. The test results indicate that the proposed integrated environment monitoring system for underground coal mines is feasible and all designs performed well as expected.

  16. Enhancement of organizational and technical solutions regarding anchoring of completed construction facilities of underground railway system to operating control

    Directory of Open Access Journals (Sweden)

    Е. Г. Козин

    2017-12-01

    Full Text Available Stages of practical realization of measures prescribed by requirements documents regarding anchoring of capital structures of underground railway system to operating control are considered in the article. On the basis of algorithm structure analysis, which includes obtaining a permit for putting into operation and cadastre works execution a range of solutions was proposed concerning optimization of construction project owner and operating organization activities with the purpose of terms reduction of capital structures handover to operation. The results of work of a commission responsible for completed underground railway system objects acceptance and putting into operation were analyzed. Considering example of object «Second entrance hall area of «Sportivnaya» station the statistical data of revealed snagging items is consolidated and dynamics of corrective actions is provided.Proposed solutions laid the foundation for corrections of requirements documents and were accepted for realization in the process of works acceptance of Saint-Petersburg underground railway system objects.

  17. Monitoring and energetic performance of two similar semi-closed greenhouse ventilation systems

    International Nuclear Information System (INIS)

    Coomans, Mathias; Allaerts, Koen; Wittemans, Lieve; Pinxteren, Dave

    2013-01-01

    Highlights: • Measurements on two semi-closed greenhouses and two traditional open greenhouses. • Mechanical and natural ventilation for dehumidification and cooling. • Analyses and comparison of installation controls, indoor climate and energy flows. • Examination of air-to-air heat recuperation efficiency in ventilation unit. • Using the semi-closed systems amounted to energy savings of 13% and 28%. - Abstract: Horticulture is an energy intensive industry when dealing with cold climates such as Western Europe. High energy prices and on-going pressure from international competition are raising demand for energy efficient solutions. In search of reducing greenhouse energy consumption, this study investigates semi-closed systems combining controlled mechanical and natural ventilation with thermal screens. Ventilated greenhouse systems (semi-closed) have been implemented in the greenhouse compartments of two Belgian horticulture research facilities: the Research Station for Vegetable Production Sint-Katelijne-Waver (PSKW) and the Research Center Hoogstraten (PCH). Additionally, two reference compartments were included for comparison of the results. The greenhouses were part of a long-term monitoring campaign in which detailed measurements with a high time resolution were gathered by a central monitoring system. A large amount of data was processed and analysed, including outdoor and indoor climatic parameters, system controls and installation measurements. The ventilated greenhouses obtained energy savings of 13% and 28% for PSKW and PCH respectively, without substantial impact on crop production or indoor climate conditions when compared to the reference compartments. A considerable amount of heat was recovered by the heat recuperation stage in the ventilation unit of PCH, accounting for 12% of the total heat demand. In general, it was demonstrated that the greenhouse heat demand can be reduced significantly by controlled dehumidification with mechanical

  18. Design of the ventilation system of the nuclear facility(I). General requirements

    International Nuclear Information System (INIS)

    Lee, K. M.; Kang, I. S.; Bae, S. M.; Kim, T. K.; Kim, K. J.

    1998-03-01

    To assure that the operation of the nuclear ventilation system is effective and economic, the reasonable design of system is essential. As the nuclear ventilation system has to meet the particular conditions; to keep the rooms at an below atmospheric pressure at all times and, furthermore, to maintain frequent air circulation in the rooms, the system needs the big rotating machinery. Consequently, the construction cost and the operational cost of the ventilation system is very high. For maximum function with the minimum cost, areas are to be divided into several zones depending on the level of radioactivity and the once-through air flow in the shortest route should be adopted. The pressure difference between the zones and the number of air circulations per unit time in the rooms must be reasonable, thus, the venting air volume should be of minimum. (author). 19 refs., 7 tabs., 21 figs

  19. Design and operation problems related to water curtain system for underground water-sealed oil storage caverns

    Directory of Open Access Journals (Sweden)

    Zhongkui Li

    2016-10-01

    Full Text Available The underground water-sealed storage technique is critically important and generally accepted for the national energy strategy in China. Although several small underground water-sealed oil storage caverns have been built in China since the 1970s, there is still a lack of experience for large-volume underground storage in complicated geological conditions. The current design concept of water curtain system and the technical instruction for system operation have limitations in maintaining the stability of surrounding rock mass during the construction of the main storage caverns, as well as the long-term stability. Although several large-scale underground oil storage projects are under construction at present in China, the design concepts and construction methods, especially for the water curtain system, are mainly based on the ideal porosity medium flow theory and the experiences gained from the similar projects overseas. The storage projects currently constructed in China have the specific features such as huge scale, large depth, multiple-level arrangement, high seepage pressure, complicated geological conditions, and high in situ stresses, which are the challenging issues for the stability of the storage caverns. Based on years' experiences obtained from the first large-scale (millions of cubic meters underground water-sealed oil storage project in China, some design and operation problems related to water curtain system during project construction are discussed. The drawbacks and merits of the water curtain system are also presented. As an example, the conventional concept of “filling joints with water” is widely used in many cases, as a basic concept for the design of the water curtain system, but it is immature. In this paper, the advantages and disadvantages of the conventional concept are pointed out, with respect to the long-term stability as well as the safety of construction of storage caverns. Finally, new concepts and principles

  20. Real-time modelling of a ventilation system for a power plant simulator

    International Nuclear Information System (INIS)

    Kocher, P.; Welfonder, E.

    1992-01-01

    This paper describes how to simulate in real-time the ventilation system of a nuclear power plant. The simulation is made under difficult computing time conditions. The ventilation system program is part of a simulator which simulates the whole nuclear power plant process in realtime. Therefore the ventilation system is split up into several smaller units. For each of these process units a real-time module has been developed, being as simple as possible but nevertheless coming close enough to the real dynamic behaviour. After that the simple real-time modules are linked together to form the total dynamic model ''ventilation system''. The continuous dynamic model developed is numerically integrated by the Euler method. The stability of this explicit method is maintained by special modelling measures such as the increasing of too low flow resistances or the limitation of too high gain factors. At the end of the paper some curves, recorded at the simulator, illustrate the behaviour of the ventilation system in the case of an accident. (author)

  1. Evaluation of a positive ventilation delivery system (PVDS) in administering technegas to the noncompliant patient

    International Nuclear Information System (INIS)

    Cook, P.; Bedford, B.; Bell, A.; Lang, P.; Leiper, C.; Prouse, A.

    1998-01-01

    Full text: Certain groups of patients have been excluded from ventilation lung scanning due to their inability to comply with instruction. Tetley Manufacturing have recently developed a Positive Ventilation Delivery System (PVDS) which assists in delivering Technegas to patients who are unable to cooperate fully. The aim of this study is to evaluate the PVDS in the clinical setting. Fifteen frail aged and psychogeriatric patients (n=l 5), mean age 78 years (range 60-93), were ventilated with Technegas using the PVDS. The decision to ventilate the patient with the PVDS was based on an initial assessment of the patients ability to comply with instructions, or failure of the conventional ventilation method, to produce an adequate count rate. Technegas was prepared in the usual manner and then delivered to the patients lungs by squeezing a black anesthetic bag synchronously with the patients breathing, until a count rate of approximately 1000 counts/second was obtained. All patients achieved a satisfactory count rate, mean 1500 counts/second (range 900 to 2300), allowing adequate ventilation images to be obtained. Time to reach this count rate varied between patients, mean 130 seconds (range 40 to 300). The number of assisted breaths also varied, mean 9 (range 3-15). In addition, four patients who required a switch from the conventional method to the PVDS, increased their initial count rate from a mean 200 ± 8% counts/second to a mean of 1300 ± 29% counts/second. This was statistically significant at p = 0.006. Our initial results demonstrate the ability of the PVDS to facilitate ventilation imaging in noncompliant patients such as the frail aged and psychogeriatric. Ventilation times and amounts of radioisotope used were acceptable, economical and practical within a busy department

  2. A Fiber Bragg Grating-Based Monitoring System for Roof Safety Control in Underground Coal Mining

    OpenAIRE

    Yiming Zhao; Nong Zhang; Guangyao Si

    2016-01-01

    Monitoring of roof activity is a primary measure adopted in the prevention of roof collapse accidents and functions to optimize and support the design of roadways in underground coalmines. However, traditional monitoring measures, such as using mechanical extensometers or electronic gauges, either require arduous underground labor or cannot function properly in the harsh underground environment. Therefore, in this paper, in order to break through this technological barrier, a novel monitoring...

  3. Effectiveness of a personalized ventilation system in reducing personal exposure against directly released simulated cough droplets.

    Science.gov (United States)

    Pantelic, J; Tham, K W; Licina, D

    2015-12-01

    The inhalation intake fraction was used as an indicator to compare effects of desktop personalized ventilation and mixing ventilation on personal exposure to directly released simulated cough droplets. A cough machine was used to simulate cough release from the front, back, and side of a thermal manikin at distances between 1 and 4 m. Cough droplet concentration was measured with an aerosol spectrometer in the breathing zone of a thermal manikin. Particle image velocimetry was used to characterize the velocity field in the breathing zone. Desktop personalized ventilation substantially reduced the inhalation intake fraction compared to mixing ventilation for all investigated distances and orientations of the cough release. The results point out that the orientation between the cough source and the breathing zone of the exposed occupant is an important factor that substantially influences exposure. Exposure to cough droplets was reduced with increasing distance between cough source and exposed occupant. The results from this study show that an advanced air distribution system such as personalized ventilation reduces exposure to cough-released droplets better than commonly applied overhead mixing ventilation. This work can inform HVAC engineers about different aspects of air distribution systems’ performance and can serve as an aid in making critical design decisions. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Reduction of nanoparticle exposure to welding aerosols by modification of the ventilation system in a workplace

    Science.gov (United States)

    Lee, Myong-Hwa; McClellan, William J.; Candela, Joe; Andrews, Dan; Biswas, Pratim

    2007-01-01

    Nanometer particle size distributions were measured in booths with two different ventilation patterns in an occupational environment with welding operations underway. The measurements were used to illustrate the impact of change of ventilation methods (existing - with ventilation ducts located at the top, modified - with ventilation ducts located below the weld bench) on the aerosol size distributions at different locations: close to the weld, in the vicinity of the welder's face, and in the exhaust duct. Particle number concentrations measured in the vicinity of the welder's face (mask) during a horizontal standard arc welding process in a booth with ventilation at the top was in the range of 7.78×105 particles cm-3 with a geometric mean size of 181 nm and geometric standard deviation of 1.8. This reduced to 1.48×104 particles cm-3 in the vicinity of the welder's face with the modified ventilation system. The clearance of the welding aerosol was also faster in the modified booth (6 min compared to 11 min in a conventional booth). Particles were collected in the booth for the various test conditions, and analyzed to determine their composition and morphology. The particles were composed of hazardous heavy metals such as manganese, chromium and nickel, and had varying morphologies.

  5. Reduction of nanoparticle exposure to welding aerosols by modification of the ventilation system in a workplace

    International Nuclear Information System (INIS)

    Lee, Myong-Hwa; McClellan, William J.; Candela, Joe; Andrews, Dan; Biswas, Pratim

    2007-01-01

    Nanometer particle size distributions were measured in booths with two different ventilation patterns in an occupational environment with welding operations underway. The measurements were used to illustrate the impact of change of ventilation methods (existing - with ventilation ducts located at the top, modified - with ventilation ducts located below the weld bench) on the aerosol size distributions at different locations: close to the weld, in the vicinity of the welder's face, and in the exhaust duct. Particle number concentrations measured in the vicinity of the welder's face (mask) during a horizontal standard arc welding process in a booth with ventilation at the top was in the range of 7.78x10 5 particles cm -3 with a geometric mean size of 181 nm and geometric standard deviation of 1.8. This reduced to 1.48x10 4 particles cm -3 in the vicinity of the welder's face with the modified ventilation system. The clearance of the welding aerosol was also faster in the modified booth (6 min compared to 11 min in a conventional booth). Particles were collected in the booth for the various test conditions, and analyzed to determine their composition and morphology. The particles were composed of hazardous heavy metals such as manganese, chromium and nickel, and had varying morphologies

  6. Dynamic Characteristics of Mechanical Ventilation System of Double Lungs with Bi-Level Positive Airway Pressure Model

    Directory of Open Access Journals (Sweden)

    Dongkai Shen

    2016-01-01

    Full Text Available In recent studies on the dynamic characteristics of ventilation system, it was considered that human had only one lung, and the coupling effect of double lungs on the air flow can not be illustrated, which has been in regard to be vital to life support of patients. In this article, to illustrate coupling effect of double lungs on flow dynamics of mechanical ventilation system, a mathematical model of a mechanical ventilation system, which consists of double lungs and a bi-level positive airway pressure (BIPAP controlled ventilator, was proposed. To verify the mathematical model, a prototype of BIPAP system with a double-lung simulators and a BIPAP ventilator was set up for experimental study. Lastly, the study on the influences of key parameters of BIPAP system on dynamic characteristics was carried out. The study can be referred to in the development of research on BIPAP ventilation treatment and real respiratory diagnostics.

  7. Software Verification and Validation Report for the 244-AR Vault Interim Stabilization Ventilation System

    International Nuclear Information System (INIS)

    YEH, T.

    2002-01-01

    This document reports on the analysis, testing and conclusions of the software verification and validation for the 244-AR Vault Interim Stabilization ventilation system. Automation control system will use the Allen-Bradley software tools for programming and programmable logic controller (PLC) configuration. The 244-AR Interim Stabilization Ventilation System will be used to control the release of radioactive particles to the environment in the containment tent, located inside the canyon of the 244-AR facility, and to assist the waste stabilization efforts. The HVAC equipment, ducts, instruments, PLC hardware, the ladder logic executable software (documented code), and message display terminal are considered part of the temporary ventilation system. The system consists of a supply air skid, temporary ductwork (to distribute airflow), and two skid-mounted, 500-cfm exhausters connected to the east filter building and the vessel vent system. The Interim Stabilization Ventilation System is a temporary, portable ventilation system consisting of supply side and exhaust side. Air is supplied to the containment tent from an air supply skid. This skid contains a constant speed fan, a pre-filter, an electric heating coil, a cooling coil, and a constant flow device (CFD). The CFD uses a passive component that allows a constant flow of air to pass through the device. Air is drawn out of the containment tent, cells, and tanks by two 500-cfm exhauster skids running in parallel. These skids are equipped with fans, filters, stack, stack monitoring instrumentation, and a PLC for control. The 500CFM exhaust skids were fabricated and tested previously for saltwell pumping activities. The objective of the temporary ventilation system is to maintain a higher pressure to the containment tent, relative to the canyon and cell areas, to prevent contaminants from reaching the containment tent

  8. Combining a building simulation with energy systems analysis to assess the benefits of natural ventilation

    DEFF Research Database (Denmark)

    Oropeza-Perez, Ivan; Østergaard, Poul Alberg; Remmen, Arne

    2013-01-01

    This article shows the combination of a thermal air flow simulation program with an energy systems analysis model in order to assess the use of natural ventilation as a method for saving energy within residential buildings in large-scale scenarios. The aim is to show the benefits for utilizing...... natural airflow instead of active systems such as mechanical ventilation or air-conditioning in buildings where the indoor temperature is over the upper limit of the comfort range. The combination is done by introducing the energy saving output - calculated with a model of natural ventilation using...... a thermal air flow simulation program - Into the energy systems analysis model. Descriptions of the energy systems in two geographical locations, i.e. Mexico and Denmark, are set up as inputs. Then, the assessment is done by calculating the energy impacts as well as environmental benefits in the energy...

  9. Evaluation of AY/AZ tank farm ventilation system during aging waste retrieval operations

    International Nuclear Information System (INIS)

    Wong, J.J.; Waters, E.D.

    1995-01-01

    Waste Management is currently planning to demonstrate mobilization of radioactive waste sludges in Tank 101-AZ beginning in October 1991. The retrieval system being designed will utilize mixer pumps that generate high-velocity, high-volume submerged liquid jets to mobilize settled solids. There is concern that these jets may also generate radioactive aerosols, some of which may be carried into the tank Ventilation system. The purpose of this study is to determine if the current AY/AZ ventilation system or the proposed ventilation system upgrade (Project W-030) will provide adequate deentrainment of liquid and solid aerosols during mixer pump operations, or if the radioactive aerosols will overload the HEPA filters

  10. Procedures and Standards for Residential Ventilation System Commissioning: An Annotated Bibliography

    Energy Technology Data Exchange (ETDEWEB)

    Stratton, J. Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wray, Craig P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-04-01

    Beginning with the 2008 version of Title 24, new homes in California must comply with ANSI/ASHRAE Standard 62.2-2007 requirements for residential ventilation. Where installed, the limited data available indicate that mechanical ventilation systems do not always perform optimally or even as many codes and forecasts predict. Commissioning such systems when they are installed or during subsequent building retrofits is a step towards eliminating deficiencies and optimizing the tradeoff between energy use and acceptable IAQ. Work funded by the California Energy Commission about a decade ago at Berkeley Lab documented procedures for residential commissioning, but did not focus on ventilation systems. Since then, standards and approaches for commissioning ventilation systems have been an active area of work in Europe. This report describes our efforts to collect new literature on commissioning procedures and to identify information that can be used to support the future development of residential-ventilation-specific procedures and standards. We recommend that a standardized commissioning process and a commissioning guide for practitioners be developed, along with a combined energy and IAQ benefit assessment standard and tool, and a diagnostic guide for estimating continuous pollutant emission rates of concern in residences (including a database that lists emission test data for commercially-available labeled products).

  11. The influence of an estimated energy saving due to natural ventilation on the Mexican energy system

    DEFF Research Database (Denmark)

    Oropeza-Perez, Ivan; Østergaard, Poul Alberg

    2014-01-01

    This article shows the impacts of the extensive use of NV (natural ventilation) in the Mexican residential sector on the Mexican energy system. By integrating a thermal-airflow simulation programme with an energy systems analysis model, the impact on the Mexican energy system of replacing air...... conditioning, in particular, with natural ventilation to cool residential buildings is determined. It is shown that when, as in Mexico, there is a relatively simple connection between supply and electricity demand, NV creates savings which could be used to reduce either the fossil-fuel-based generation...

  12. Design and simulation of a new energy conscious system, (ventilation and thermal performance simulation)

    Energy Technology Data Exchange (ETDEWEB)

    Gadi, Mohamed B. [Nottingham Univ., School of the Built Environment, Nottingham (United Kingdom)

    2000-04-01

    This paper presents the results of simulating the ventilation and thermal performance of a new passive cooling and heating system. The new systems was integrated into the roof of a typical contemporary North African house, which was modelled and mounted inside a wind tunnel, for natural ventilation simulation. Thermal performance of the new systems was simulated using a new computer programme (BTS), developed by the author. Results are presented in terms of indoor temperature and CATD and HATD, which are newly introduced concepts in defining the building cooling and heating loads. (Author)

  13. A risk measurement tool for an underground electricity distribution system considering the consequences and uncertainties of manhole events

    International Nuclear Information System (INIS)

    Garcez, Thalles Vitelli; Teixeira de Almeida, Adiel

    2014-01-01

    This paper explores a risk measure of underground vaults that considers the consequences of arc faults. The increasing use of underground systems, together with the aging of networks, the lack of maintenance and interference from other (third party) underground systems nearby have caused many accidents in urban areas, thus endangering human life. The involvement of a large number (hundreds or thousands) of underground vaults with different characteristics, the lack of historical data on modes of failure, the rarity of the occurrence of some faults, the magnitude of their consequences and the involvement of a complex environment surrounding the hazard zone make risk management even more complex and uncertain. Furthermore, given that the (monetary, time, staff, etc.) resources of an electrical power company are limited and scarce, it is necessary to use decision-making tools that aggregate the consequences and the uncertainties to assess the risks jointly with the preference structure of the company, thus solving the problem more realistically. Therefore, this paper puts forward the use of an additional risk analysis for manhole events in underground electrical distribution networks with a view to its being used as a decision aid tool in risk management. As an illustration of the use of the risk measurement tool proposed, a numerical application is presented. The result rather than showing a ranking of underground vaults, gives a measure of the risk used that can show the decision-maker (DM) how much better one group of alternatives (formed by alternatives with quite similar risk values) is than other groups, based on the DM’s attitude to risk and grounded on the axiomatic structure of utility theory. - Highlights: • The paper proposes a risk measure of underground vaults for manhole events. • It makes risk analysis in underground electrical distribution networks. • It makes more than show a risk ranking of underground vaults. • It can show to the DM how

  14. A perfluorochemical loss/restoration (L/R) system for tidal liquid ventilation.

    Science.gov (United States)

    Libros, R; Philips, C M; Wolfson, M R; Shaffer, T H

    2000-01-01

    Tidal liquid ventilation is the transport of dissolved respiratory gases via volume exchange of perfluorochemical (PFC) liquid to and from the PFC-filled lung. All gas-liquid surface tension is eliminated, increasing compliance and providing lung protection due to lower inflation pressures. Tidal liquid ventilation is achieved by cycling fluid from a reservoir to and from the lung by a ventilator. Current approaches are microprocessor-based with feedback control. During inspiration, warmed oxygenated PFC liquid is pumped from a fluid reservoir/gas exchanger into the lung. PFC fluid is conserved by condensing (60-80% efficiency) vapor in the expired gas. A feedback-control system was developed to automatically replace PFC lost due to condenser inefficiency. This loss/restoration (L/R) system consists of a PFC-vapor thermal detector (+/- 2.5%), pneumatics, amplifiers, a gas flow detector (+/- 1%), a PFC pump (+/- 5%), and a controller. Gravimetric studies of perflubron loss from a flask due to evaporation were compared with experimental L/R results and found to be within +/- 1.4%. In addition, when L/R studies were conducted with a previously reported liquid ventilation system over a four-hour period, the L/R system maintained system perflubron volume to within +/- 1% of prime volume and 11.5% of replacement volume, and the difference between experimental PFC loss and that of the L/R system was 1.8 mL/hr. These studies suggest that the PFC L/R system may have significant economic (appropriate dosing for PFC loss) as well as physiologic (maintenance of PFC inventory in the lungs and liquid ventilator) impact on liquid ventilation procedures.

  15. Laboratory study of subjective perceptions to low temperature heating systems with exhaust ventilation in Nordic countries

    DEFF Research Database (Denmark)

    Jin, Quan; Simone, Angela; Olesen, Bjarne W.

    2017-01-01

    in Nordic countries for greater energy efficiency, this study focused on human subjects’ thermal sensation, thermal comfort, thermal acceptability, draft acceptability, and perceived air quality when three low-temperature heating systems were used: conventional radiator, ventilation radiator, or floor...... sensation and thermal comfort between the three heating systems. Ventilation radiator promised a comfortable indoor environment with a decreased water supply temperature and floor heating with exhaust ventilation can provide a basic thermal comfort level. Thermal acceptability and draft acceptability show...... variations in different heating systems. Gender has significant influences on thermal sensation, draft acceptability, and preference of clo values. Personal thermal preference is observed between males and females. The males prefer to dress lighter than the females, but both can get the same thermal comfort...

  16. Ventilation Transport Trade Study for Future Space Suit Life Support Systems

    Science.gov (United States)

    Kempf, Robert; Vogel, Matthew; Paul, Heather L.

    2008-01-01

    A new and advanced portable life support system (PLSS) for space suit surface exploration will require a durable, compact, and energy efficient system to transport the ventilation stream through the space suit. Current space suits used by NASA circulate the ventilation stream via a ball-bearing supported centrifugal fan. As NASA enters the design phase for the next generation PLSS, it is necessary to evaluate available technologies to determine what improvements can be made in mass, volume, power, and reliability for a ventilation transport system. Several air movement devices already designed for commercial, military, and space applications are optimized in these areas and could be adapted for EVA use. This paper summarizes the efforts to identify and compare the latest fan and bearing technologies to determine candidates for the next generation PLSS.

  17. Going underground

    Energy Technology Data Exchange (ETDEWEB)

    Winqvist, T.; Mellgren, K.-E. (eds.)

    1988-01-01

    Contains over 100 short articles on underground structures and tunneling based largely on Swedish experience. Includes papers on underground workers - attitudes and prejudices, health investigations, the importance of daylight, claustrophobia; excavation, drilling and blasting; hydroelectric power plants; radioactive waste disposal; district heating; oil storage; and coal storage.

  18. Heat transfer analysis of underground U-type heat exchanger of ground source heat pump system.

    Science.gov (United States)

    Pei, Guihong; Zhang, Liyin

    2016-01-01

    Ground source heat pumps is a building energy conservation technique. The underground buried pipe heat exchanging system of a ground source heat pump (GSHP) is the basis for the normal operation of an entire heat pump system. Computational-fluid-dynamics (CFD) numerical simulation software, ANSYS-FLUENT17.0 have been performed the calculations under the working conditions of a continuous and intermittent operation over 7 days on a GSHP with a single-well, single-U and double-U heat exchanger and the impact of single-U and double-U buried heat pipes on the surrounding rock-soil temperature field and the impact of intermittent operation and continuous operation on the outlet water temperature. The influence on the rock-soil temperature is approximately 13 % higher for the double-U heat exchanger than that of the single-U heat exchanger. The extracted energy of the intermittent operation is 36.44 kw·h higher than that of the continuous mode, although the running time is lower than that of continuous mode, over the course of 7 days. The thermal interference loss and quantity of heat exchanged for unit well depths at steady-state condition of 2.5 De, 3 De, 4 De, 4.5 De, 5 De, 5.5 De and 6 De of sidetube spacing are detailed in this work. The simulation results of seven working conditions are compared. It is recommended that the side-tube spacing of double-U underground pipes shall be greater than or equal to five times of outer diameter (borehole diameter: 180 mm).

  19. Systems management support for ERCDC study of undergrounding and berm containment. Interim report. Preliminary program assessment and follow-on program development

    Energy Technology Data Exchange (ETDEWEB)

    1977-08-01

    Interim results of a study being conducted with respect to the technological aspects of the costs and benefits of underground nuclear power plant construction in direct support of the California Energy Commission's legislative mandate in this area are presented. The program was directed towards problem scoping, methodology evaluation, program definition and planning for subsequent, more detailed investigations of underground facility designs and their potential advantages and disadvantages. The material presented describes the results of (a) systems analyses which were conducted to determine logical requirements for determination of those elements of a nuclear power plant which should be constructed underground; (b) bounding estimates of incremental plant costs for a variety of underground concepts; (c) applicable prior experience in underground facility design and construction which could be used to identify potential sources of strength and weaknessees of underground nuclear power plants; (d) estimates of seismic environments for underground construction in California; (e) preliminary descriptions of underground reactor accident scenarios; (f) bounding estimates of the consequences of such accidents, in terms of comparisons of relative emissions of radioactivity with respect to similar accidents for surface-sited nuclear power plants and (g) results of analyses of several other important technological aspects of the problem. A description is also provided of the program development work performed to provide planning and criteria for subsequent investigations to determine: (a) definitive underground nuclear power plant designs and costs, and (b) estimates of accident consequences in underground nuclear power plants.

  20. Systems management support for ERCDC study of undergrounding and berm containment. Interim report. Preliminary program assessment and follow-on program development

    International Nuclear Information System (INIS)

    1977-08-01

    Interim results of a study being conducted with respect to the technological aspects of the costs and benefits of underground nuclear power plant construction in direct support of the California Energy Commission's legislative mandate in this area are presented. The program was directed towards problem scoping, methodology evaluation, program definition and planning for subsequent, more detailed investigations of underground facility designs and their potential advantages and disadvantages. The material presented describes the results of (a) systems analyses which were conducted to determine logical requirements for determination of those elements of a nuclear power plant which should be constructed underground; (b) bounding estimates of incremental plant costs for a variety of underground concepts; (c) applicable prior experience in underground facility design and construction which could be used to identify potential sources of strength and weaknessees of underground nuclear power plants; (d) estimates of seismic environments for underground construction in California; (e) preliminary descriptions of underground reactor accident scenarios; (f) bounding estimates of the consequences of such accidents, in terms of comparisons of relative emissions of radioactivity with respect to similar accidents for surface-sited nuclear power plants and (g) results of analyses of several other important technological aspects of the problem. A description is also provided of the program development work performed to provide planning and criteria for subsequent investigations to determine: (a) definitive underground nuclear power plant designs and costs, and (b) estimates of accident consequences in underground nuclear power plants

  1. Parameter estimation of an artificial respiratory system under mechanical ventilation following a noisy regime

    Directory of Open Access Journals (Sweden)

    Marcus Henrique Victor Júnior

    Full Text Available Abstract Introduction: This work concerns the assessment of a novel system for mechanical ventilation and a parameter estimation method in a bench test. The tested system was based on a commercial mechanical ventilator and a personal computer. A computational routine was developed do drive the mechanical ventilator and a parameter estimation method was utilized to estimate positive end-expiratory pressure, resistance and compliance of the artificial respiratory system. Methods The computational routine was responsible for establishing connections between devices and controlling them. Parameters such as tidal volume, respiratory rate and others can be set for standard and noisy ventilation regimes. Ventilation tests were performed directly varying parameters in the system. Readings from a calibrated measuring device were the basis for analysis. Adopting a first-order linear model, the parameters could be estimated and the outcomes statistically analysed. Results Data acquisition was effective in terms of sample frequency and low noise content. After filtering, cycle detection and estimation took place. Statistics of median, mean and standard deviation were calculated, showing consistent matching with adjusted values. Changes in positive end-expiratory pressure statistically imply changes in compliance, but not the opposite. Conclusion The developed system was satisfactory in terms of clinical parameters. Statistics exhibited consistent relations between adjusted and estimated values, besides precision of the measurements. The system is expected to be used in animals, with a view to better understand the benefits of noisy ventilation, by evaluating the estimated parameters and performing cross relations among blood gas, ultrasonography and electrical impedance tomography.

  2. Radon in Brazilian underground mines.

    Science.gov (United States)

    Ayres da Silva, Anna Luiza Marques; Eston, Sérgio Médici; Iramina, Wilson Siguemasa; Francisca, Diego Diegues

    2018-02-14

    Radon is a chemically inert noble radioactive gas found in several radioactive decay chains. In underground mines, especially those that contain or have contained ores associated with uranium-bearing minerals, workers might be exposed to high levels of radon and its decay products (RDP). This work aimed to investigate whether the exposure of workers to radon gas and its progeny has been evaluated in Brazilian non-uranium and non-thorium underground mines. If so, the results and control measures undertaken or recommended to maintain the concentrations under Brazilian occupational exposure limits (OELs) were documented. The adopted methodology consisted of three main phases. The first was an extensive bibliographical survey of the concentration levels of radon and RDP, and the radiation dose estimates, considering measurements made heretofore by various Brazilian researchers and exhibiting original measurement work undertaken by the one of the authors (mine O). In the second phase, the values obtained were compared with OELs. In the third phase, it was verified whether any control measures were undertaken in the mines with high exposure of workers to radon and its progeny, and if so, the adopted controls were determined. Data of radon concentration obtained from 52 campaigns in 40 underground mines were analyzed. The results showed that the assessment of the exposure of workers to radon and its progeny was undertaken in many mines at least once, and that in 62.5% of the mines, when visited for the first time, the radon levels throughout them were below the Brazilian OELs. As expected, the main control measure adopted or recommended was the improvement of the ventilation system. © 2018 IOP Publishing Ltd.

  3. A method for evaluating the problem complex of choosing the ventilation system for a new building

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2007-01-01

    The application of a ventilation system in a new building is a multidimensional complex problem that involves quantifiable and non-quantifiable data like energy consump¬tion, indoor environment, building integration and architectural expression. This paper presents a structured method...... for evaluating the performance of a ventilation system in the design proces by treating quantifiable and non-quantifiable datasets together. The method is based on general morphological analysis and applies cross-consistency assessment for reducing the problem complex, thus treating the multi-dimensionality...

  4. : ventilators for noninvasive ventilation

    OpenAIRE

    Fauroux , Brigitte; Leroux , Karl; Desmarais , Gilbert; Isabey , Daniel; Clément , Annick; Lofaso , Frédéric; Louis , Bruno

    2008-01-01

    International audience; The aim of the present study was to evaluate the performance characteristics of all the ventilators proposed for home noninvasive positive-pressure ventilation in children in France. The ventilators (one volume-targeted, 12 pressure-targeted and four dual) were evaluated on a bench which simulated six different paediatric ventilatory patterns. For each ventilator, the quality of the inspiratory and expiratory trigger and the ability to reach and maintain the preset pre...

  5. Cleanup and Dismantling of Highly Contaminated Ventilation Systems Using Robotic Tools - 13162

    International Nuclear Information System (INIS)

    Chambon, Frederic; CIZEL, Jean-Pierre; Blanchard, Samuel

    2013-01-01

    The UP1 plant reprocessed nearly 20,000 tons of used natural uranium gas cooled reactor fuel coming from the first generation of civil nuclear reactors in France. Following operating incidents in the eighties, the ventilation system of the continuous dissolution line facility was shut down and replaced. Two types of remote controlled tool carriers were developed to perform the decontamination and dismantling operations of the highly contaminated ventilation duct network. The first one, a dedicated small robot, was designed from scratch to retrieve a thick powder deposit within a duct. The robot, managed and confined by two dedicated glove boxes, was equipped for intervention inside the ventilation duct and used for carrying various cleanup and inspection tools. The second type, consisting of robotic tools developed on the base of an industrial platform, was used for the clean-up and dismantling of the ventilation duct system. Depending on the type of work to be performed, on the shape constraints of the rooms and any equipment to be dismantled, different kinds of robotic tools were developed and installed on a Brokk 40 carrier. After more than ten years of ventilation duct D and D operations at the UP1 plant, a lot of experience was acquired about remote operations. The three main important lessons learned in terms of remote controlled operation are: characterizing the initial conditions as much as reasonably possible, performing non-radioactive full scale testing and making it as simple and modular as possible. (authors)

  6. FY 1999 research and development results. Preparatory study for the underground thermal energy storage system; 1999 nendo chichu jiban chikunetsu system gijutsu sendo kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-05-01

    The study is conducted for the underground thermal energy storage system which utilizes heat capacity of the underground, e.g., aquifer, to exchange heat with the underground, and the FY 1999 results are described. For establishment of the concept of the underground heat storage systems, 2 sites are selected for each of Tokyo, Osaka and Sapporo for the study as the geological ground models, for their weather characteristics. Two cases are considered for the site where underground heat exchangers are installed, open space and immediately below a building. The heat-storage system comprises a high-efficiency heat pump, water heat-storage tank and cooling tower. The evaluation results indicate that energy saving rate of 37% or more and CO2 reduction rate of 9.5% or more are achievable in all areas except Sapporo, i.e., Tokyo and Osaka. The economic evaluation results indicate that the simple pay-out period is around 100 years for Tokyo and Osaka, and 80 years for Sapporo. The underground heat storage system is approximately 10% lower in life-cycle cost than the conventional system, 3 versus 3.3 billion yen for the period of 60 years. (NEDO)

  7. Energy and exergy performance of residential heating systems with separate mechanical ventilation

    International Nuclear Information System (INIS)

    Zmeureanu, Radu; Yu Wu, Xin

    2007-01-01

    The paper brings new evidence on the impact of separate mechanical ventilation system on the annual energy and exergy performance of several design alternatives of residential heating systems, when they are designed for a house in Montreal. Mathematical models of residential heating, ventilation and domestic hot water (HVAC-DHW) systems, which are needed for this purpose, are developed and furthermore implemented in the Engineering Equation Solver (EES) environment. The Coefficient of Performance and the exergy efficiency are estimated as well as the entropy generation and exergy destruction of the overall system. The equivalent greenhouse gas emissions due to the on-site and off-site use of primary energy sources are also estimated. The addition of a mechanical ventilation system with heat recovery to any HVAC-DHW system discussed in the paper increases the energy efficiency; however, it decreases the exergy efficiency, which indicates a potential long-term damaging impact on the natural environment. Therefore, the use of a separate mechanical ventilation system in a house should be considered with caution, and recommended only when other means for controlling the indoor air quality cannot be applied

  8. Optimization of Waste Collection System Using Underground Containers with Source Separation Plan (Case Study: Zone 3 of Yazd Municipality, Iran

    Directory of Open Access Journals (Sweden)

    Maryam Morakabatchian

    2017-12-01

    Conclusion: Optimization of urban waste collection system using underground containers for wet waste and the use of temporary stations of dry wastes, considering the significant economic, environmental and aesthetic advantages can be considered as an appropriate option in Iranian cities especially in areas with hot and humid weather such as Yazd.

  9. Review of underground logistic systems in the Netherlands : An ex-post evaluation of barriers, enablers and spin-offs

    NARCIS (Netherlands)

    Wiegmans, B.W.; Visser, J.; Konings, R.; Pielage, B.J.A.

    2010-01-01

    Now, 10 years after the first plans, we analyse in this paper what has happened with Underground Logistic Systems (ULS). The major question in this paper is: Which barriers and enablers led to the failure of ULS and what ULS spin-offs can be found nowadays? Several factors can be classified as

  10. A Comparison of Impedance-Based Fault Location Methods for Power Underground Distribution Systems

    Directory of Open Access Journals (Sweden)

    Enrique Personal

    2016-12-01

    Full Text Available In the last few decades, the Smart Grid paradigm presence has increased within power systems. These new kinds of networks demand new Operations and Planning approaches, following improvements in the quality of service. In this sense, the role of the Distribution Management System, through its Outage Management System, is essential to guarantee the network reliability. This system is responsible for minimizing the consequences arising from a fault event (or network failure. Obviously, knowing where the fault appears is critical for a good reaction of this system. Therefore, several fault location techniques have been proposed. However, most of them provide individual results, associated with specific testbeds, which make the comparison between them difficult. Due to this, a review of fault location methods has been done in this paper, analyzing them for their use on underground distribution lines. Specifically, this study is focused on an impedance-based method because their requirements are in line with the typical instrumentation deployed in distribution networks. This work is completed with an exhaustive analysis of these methods over a PSCADTM X4 implementation of the standard IEEE Node Test Feeder, which truly allows us to consistently compare the results of these location methods and to determine the advantages and drawbacks of each of them.

  11. 46 CFR 108.437 - Pipe sizes and discharge rates for enclosed ventilation systems for rotating electrical equipment.

    Science.gov (United States)

    2010-10-01

    ... enclosed ventilation systems for rotating electrical equipment. (a) The minimum pipe size for the initial... 46 Shipping 4 2010-10-01 2010-10-01 false Pipe sizes and discharge rates for enclosed ventilation systems for rotating electrical equipment. 108.437 Section 108.437 Shipping COAST GUARD, DEPARTMENT OF...

  12. Parametric instabilities of rotor-support systems with application to industrial ventilators

    Science.gov (United States)

    Parszewski, Z.; Krodkiemski, T.; Marynowski, K.

    1980-01-01

    Rotor support systems interaction with parametric excitation is considered for both unequal principal shaft stiffness (generators) and offset disc rotors (ventilators). Instability regions and types of instability are computed in the first case, and parametric resonances in the second case. Computed and experimental results are compared for laboratory machine models. A field case study of parametric vibrations in industrial ventilators is reported. Computed parametric resonances are confirmed in field measurements, and some industrial failures are explained. Also the dynamic influence and gyroscopic effect of supporting structures are shown and computed.

  13. Diffuse ceiling ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen

    Diffuse ceiling ventilation is an innovative ventilation concept where the suspended ceiling serves as air diffuser to supply fresh air into the room. Compared with conventional ventilation systems, diffuse ceiling ventilation can significantly reduce or even eliminate draught risk due to the low...... momentum supply. In addition, this ventilation system uses a ceiling plenum to deliver air and requires less energy consumption for air transport than full-ducted systems. There is a growing interest in applying diffuse ceiling ventilation in offices and other commercial buildings due to the benefits from...... both thermal comfort and energy efficient aspects. The present study aims to characterize the air distribution and thermal comfort in the rooms with diffuse ceiling ventilation. Both the stand-alone ventilation system and its integration with a radiant ceiling system are investigated. This study also...

  14. Design, Implementation & Assessment of Local Exhaust Ventilation System and dust collectors for crushing unit

    Directory of Open Access Journals (Sweden)

    Farshid Ghorbani shahna

    2015-09-01

    Full Text Available Background & objective: Industrial ventilation systems and dust collectors are effective solutions to reduce particulate emissions in the workplace and environmental in mineral processes. In this study, Local Exhaust Ventilation System and dust collectors for control of emitted silica, coke, silicon carbide dusts from crushing unit was designed and evaluated. Methods: : Local Exhaust ventilation system based on standards and guides was designed and implemented after field study of the processes and sources of air pollutants. A set comprised of the four parallel cyclones (Stairmand model and a new design of the scrubber had been used for dust control. After set-up of systems, its effectiveness in reducing the exposure of workers in the workshops and dust collecting were assessed. Results: Test results were significant differences between the concentration of particles in both on and off the ventilation system revealed (P <0.05. The system has been implemented as means of personal exposure to pollutants and environmental emissions were reduced 93.01% and 64.64%, respectively. Also, alone and integrated collection efficiency of cyclone and scrubber, were 94.2%, 59.05% and 97.4%, respectively. The results show good agreement with the values of the parameters ventilation system was designed. Conclusion: Implementation of integrated dust collectors is a good option in industries that have the financial and technical constraints to improve change processes and devices. This method with attainment to health and environmental standards not only can be resolve of the pollution problems, but also will be economically justified of such projects with reduction of depreciation expense and dust recycling.

  15. Biodegradation of cis-1,2-Dichloroethene in Simulated Underground Thermal Energy Storage Systems.

    Science.gov (United States)

    Ni, Zhuobiao; van Gaans, Pauline; Smit, Martijn; Rijnaarts, Huub; Grotenhuis, Tim

    2015-11-17

    Underground thermal energy storage (UTES) use has showed a sharp rise in numbers in the last decades, with aquifer thermal energy storage (ATES) and borehole thermal energy storage (BTES) most widely used. In many urban areas with contaminated aquifers, there exists a desire for sustainable heating and cooling with UTES and a need for remediation. We investigated the potential synergy between UTES and bioremediation with batch experiments to simulate the effects of changing temperature and liquid exchange that occur in ATES systems, and of only temperature change occurring in BTES systems on cis-DCE reductive dechlorination. Compared to the natural situation (NS) at a constant temperature of 10 °C, both UTES systems with 25/5 °C for warm and cold well performed significantly better in cis-DCE (cis-1,2-dichloroethene) removal. The overall removal efficiency under mimicked ATES and BTES conditions were respectively 13 and 8.6 times higher than in NS. Inoculation with Dehalococcoides revealed that their initial presence is a determining factor for the dechlorination process. Temperature was the dominating factor when Dehalococcoides abundance was sufficient. Stimulated biodegradation was shown to be most effective in the mimicked ATES warm well because of the combined effect of suitable temperature, sustaining biomass growth, and regular cis-DCE supply.

  16. Ventilator-Related Adverse Events: A Taxonomy and Findings From 3 Incident Reporting Systems

    Science.gov (United States)

    Pham, Julius Cuong; Williams, Tamara L; Sparnon, Erin M; Cillie, Tam K; Scharen, Hilda F; Marella, William M

    2016-01-01

    BACKGROUND: In 2009, researchers from Johns Hopkins University's Armstrong Institute for Patient Safety and Quality; public agencies, including the FDA; and private partners, including the Emergency Care Research Institute and the University HealthSystem Consortium (UHC) Safety Intelligence Patient Safety Organization, sought to form a public-private partnership for the promotion of patient safety (P5S) to advance patient safety through voluntary partnerships. The study objective was to test the concept of the P5S to advance our understanding of safety issues related to ventilator events, to develop a common classification system for categorizing adverse events related to mechanical ventilators, and to perform a comparison of adverse events across different adverse event reporting systems. METHODS: We performed a cross-sectional analysis of ventilator-related adverse events reported in 2012 from the following incident reporting systems: the Pennsylvania Patient Safety Authority's Patient Safety Reporting System, UHC's Safety Intelligence Patient Safety Organization database, and the FDA's Manufacturer and User Facility Device Experience database. Once each organization had its dataset of ventilator-related adverse events, reviewers read the narrative descriptions of each event and classified it according to the developed common taxonomy. RESULTS: A Pennsylvania Patient Safety Authority, FDA, and UHC search provided 252, 274, and 700 relevant reports, respectively. The 3 event types most commonly reported to the UHC and the Pennsylvania Patient Safety Authority's Patient Safety Reporting System databases were airway/breathing circuit issue, human factor issues, and ventilator malfunction events. The top 3 event types reported to the FDA were ventilator malfunction, power source issue, and alarm failure. CONCLUSIONS: Overall, we found that (1) through the development of a common taxonomy, adverse events from 3 reporting systems can be evaluated, (2) the types of

  17. The application and implementation of optimized mine ventilation on demand (OMVOD) at the Xstrata Nickel Rim South Mine, Sudbury, Ontario

    International Nuclear Information System (INIS)

    Bartsch, E.; Laine, M.; Andersen, M.

    2010-01-01

    An Optimized Mine Ventilation on Demand (OMVOD) system has been installed at the Xstrata Nickel Rim South Mine in Sudbury. Developed by Simsmart Technologies, the OMVOD system monitors and controls air quality and quantity through real time dynamic automation. A ventilation on demand (VOD) system was needed to remove diesel particulate matter (DPM), carbon monoxide (CO) and nitrogen dioxide (NO 2 ). This paper described the real-time tracking and monitoring of the OMVOD system and optimization of ventilation equipment. Simsmart's OMVOD system was shown to reduce energy costs while improve air quality in the underground mine. 7 refs., 3 tabs., 8 figs.

  18. Calculation notes in support of ammonia releases from waste tank ventilation systems

    International Nuclear Information System (INIS)

    Wojdac, L.F.

    1996-01-01

    Ammonia is generated in waste tanks via the degradation of nitrogen compounds. The ammonia is released from the liquids by a mechanism which is dependent on temperature, pH, ionic strength and ammonia concentration. The release of ammonia to the environment occurs via diffusion of ammonia through a stagnant air mass and into the ventilation system

  19. A method for evaluating the problem complex of choosing the ventilation system for a new building

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2007-01-01

    The application of a ventilation system in a new building is a multidimensional complex problem that involves quantifiable and non-quantifiable data like energy consump¬tion, indoor environment, building integration and architectural expression. This paper presents a structured method for evaluat...

  20. Performance of Counter Flow Heat Recovery Ventilation Systems in Dwellings Considering the Influence of Uncertainties

    NARCIS (Netherlands)

    Yang, Z.; Cauberg, J.J.M.; Tenpierik, M.J.

    2012-01-01

    Both critical and optimistic claims have been made regarding the performance of heat recovery ventilation systems (HRVS) in dwellings. Such arguments are raised partly because two key aspects are not fully clarified, i.e. the performance criteria and the influence of uncertainties. In the current

  1. Measuring Airflow in Local Exhaust Ventilation Systems. Module 23. Vocational Education Training in Environmental Sciences.

    Science.gov (United States)

    Consumer Dynamics Inc., Rockville, MD.

    This module, one of 25 on vocational education training for careers in environmental health occupations, contains self-instructional materials on measuring airflow in local exhaust ventilation systems. Following guidelines for students and instructors and an introduction that explains what the student will learn are three lessons: (1) naming each…

  2. Ventilation system consequence calculations to support salt well pumping single-shell tank 241-A-101

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, G.W.

    1997-05-07

    This document presents the radiological dose and toxicological exposure calculations for an accident scenario involved with the ventilation system used to support salt well pumping single-shell tank 241-A-101. This tank has been listed on the Hydrogen Watch List.

  3. Ventilation system consequence calculations to support salt well pumping single-shell tank 241-A-101

    International Nuclear Information System (INIS)

    Ryan, G.W.

    1997-01-01

    This document presents the radiological dose and toxicological exposure calculations for an accident scenario involved with the ventilation system used to support salt well pumping single-shell tank 241-A-101. This tank has been listed on the Hydrogen Watch List

  4. Positioning of sensors for control of ventilation systems in broiler houses: a case study

    Directory of Open Access Journals (Sweden)

    Thayla Morandi Ridolfi de Carvalho Curi

    Full Text Available ABSTRACT Ventilation systems are incorporated at intensive poultry farms to control environment conditions and thermal comfort of broilers. The ventilation system operates based on environmental data, particularly measured by sensors of temperature and relative humidity. Sensors are placed at different positions of the facility. Quality, number and positioning of the sensors are critical factors to achieve an efficient performance of the system. For this reason, a strategic positioning of the sensors associated to controllers could support the maintenance and management of the microclimate inside the facility. This research aims to identify the three most representative points for the positioning of sensors in order to support the ventilation system during the critical period from 12h00 to 15h00 on summer days. Temperature, relative humidity and wind speed were measured in four different tunnel ventilated barns at the final stage of the production cycle. The descriptive analysis was performed on these data. The Temperature and Humidity Index (THI was also calculated. Then, the geostatistical analysis of THI was performed by GS+ and the position of sensors was determined by ordinary kriging. The methodology was able to detect the most representative points for the positioning of sensors in a case study (southeastern Brazil. The results suggested that this strategic positioning would help controllers to obtain a better inference of the microclimate during the studied period (the hottest microclimate, considered critical in Brazil. In addition, these results allow developing a future road map for a decision support system based on 24 h monitoring of the ventilation systems in broiler houses.

  5. Dispersion of exhaled droplet nuclei in a two-bed hospital ward with three different ventilation systems

    DEFF Research Database (Denmark)

    Qian, H.; Li, Y.; Nielsen, Peter V.

    2006-01-01

    hospital ward with three ventilation systems, i.e. mixing, downward and displacement ventilation. Two life-size breathing thermal manikins were used to simulate a source patient and a receiving patient. The exhalation jet from a bed-lying manikin was visualized using smoke. N2O was used as tracer gas...... with displacement ventilation. This work is useful for identifying an appropriate ventilation method that can remove droplet nuclei more effectively and minimize the risk of cross-infections in a hospital ward environment....

  6. Secondary Containment for Underground Storage Tank Systems - 2005 Energy Policy Act

    Science.gov (United States)

    These grant guidelines implement the secondary containment provision in Section 9003(i)(1) of the Solid Waste Disposal Act, enacted by the Underground Storage Tank Compliance Act, part of the Energy Policy Act of 2005.

  7. A novel fiber-optic measurement system for the evaluation of performances of neonatal pulmonary ventilators

    Science.gov (United States)

    Battista, L.; Scorza, A.; Botta, F.; Sciuto, S. A.

    2016-02-01

    Published standards for the performance evaluation of pulmonary ventilators are mainly directed to manufacturers rather than to end-users and often considered inadequate or not comprehensive. In order to contribute to overcome the problems above, a novel measurement system was proposed and tested with waveforms of mechanical ventilation by means of experimental trials carried out with infant ventilators typically used in neonatal intensive care units: the main quantities of mechanical ventilation in newborns are monitored, i.e. air flow rate, differential pressure and volume from infant ventilator are measured by means of two novel fiber-optic sensors (OFSs) developed and characterized by the authors, while temperature and relative humidity of air mass are obtained by two commercial transducers. The proposed fiber-optic sensors (flow sensor Q-OFS, pressure sensor P-OFS) showed measurement ranges of air flow and pressure typically encountered in neonatal mechanical ventilation, i.e. the air flow rate Q ranged from 3 l min-1 to 18 l min-1 (inspiratory) and from  -3 l min-1 to  -18 l min-1 (expiratory), the differential pressure ΔP ranged from  -15 cmH2O to 15 cmH2O. In each experimental trial carried out with different settings of the ventilator, outputs of the OFSs are compared with data from two reference sensors (reference flow sensor RF, reference pressure sensor RP) and results are found consistent: flow rate Q showed a maximum error between Q-OFS and RF up to 13 percent, with an output ratio Q RF/Q OFS of not more than 1.06  ±  0.09 (least square estimation, 95 percent confidence level, R 2 between 0.9822 and 0.9931). On the other hand the maximum error between P-OFS and RP on differential pressure ΔP was lower than 10 percent, with an output ratio ΔP RP/ΔP OFS between 0.977  ±  0.022 and 1.0  ±  0.8 (least square estimation, 95 percent confidence level, R 2 between 0.9864 and 0.9876). Despite the possible improvements

  8. A novel fiber-optic measurement system for the evaluation of performances of neonatal pulmonary ventilators

    International Nuclear Information System (INIS)

    Battista, L; Scorza, A; Botta, F; Sciuto, S A

    2016-01-01

    Published standards for the performance evaluation of pulmonary ventilators are mainly directed to manufacturers rather than to end-users and often considered inadequate or not comprehensive. In order to contribute to overcome the problems above, a novel measurement system was proposed and tested with waveforms of mechanical ventilation by means of experimental trials carried out with infant ventilators typically used in neonatal intensive care units: the main quantities of mechanical ventilation in newborns are monitored, i.e. air flow rate, differential pressure and volume from infant ventilator are measured by means of two novel fiber-optic sensors (OFSs) developed and characterized by the authors, while temperature and relative humidity of air mass are obtained by two commercial transducers. The proposed fiber-optic sensors (flow sensor Q-OFS, pressure sensor P-OFS) showed measurement ranges of air flow and pressure typically encountered in neonatal mechanical ventilation, i.e. the air flow rate Q ranged from 3 l min −1 to 18 l min −1 (inspiratory) and from  −3 l min −1 to  −18 l min −1 (expiratory), the differential pressure ΔP ranged from  −15 cmH 2 O to 15 cmH2O. In each experimental trial carried out with different settings of the ventilator, outputs of the OFSs are compared with data from two reference sensors (reference flow sensor RF, reference pressure sensor RP) and results are found consistent: flow rate Q showed a maximum error between Q-OFS and RF up to 13 percent, with an output ratio Q RF /Q OFS of not more than 1.06  ±  0.09 (least square estimation, 95 percent confidence level, R 2 between 0.9822 and 0.9931). On the other hand the maximum error between P-OFS and RP on differential pressure ΔP was lower than 10 percent, with an output ratio ΔP RP /ΔP OFS between 0.977  ±  0.022 and 1.0  ±  0.8 (least square estimation, 95 percent confidence level, R 2 between 0.9864 and 0.9876). Despite the

  9. Morpho-anatomical features of underground systems in six Asteraceae species from the Brazilian Cerrado

    Directory of Open Access Journals (Sweden)

    Beatriz Appezzato-da-Glória

    2011-09-01

    Full Text Available In the Brazilian Cerrado (neotropical savanna, the development of bud-bearing underground systems as adaptive structures to fire and dry periods can comprise an important source of buds for this ecosystem, as already demonstrated in the Brazilian Campos grasslands and North American prairies. Asteraceae species from both woody and herbaceous strata have subterranean organs that accumulate carbohydrates, reinforcing the adaptive strategy of these plants to different environmental conditions. This study aims to analyse the morpho-anatomy of underground systems of six species of Asteraceae (Mikania cordifolia L.f. Willd., Mikania sessilifolia DC, Trixis nobilis (Vell. Katinas, Pterocaulon alopecuroides (Lam. DC., Vernonia elegans Gardner and Vernonia megapotamica Spreng., to describe these structures and to verify the occurrence and origin of shoot buds, and to analyse the presence of reserve substances. Individuals sampled in Cerrado areas in São Paulo State showed thick underground bud-bearing organs, with adventitious or lateral roots and presence of fructans. Xylopodium was found in all studied species, except for Trixis nobilis, which had stem tuber. The presence of fructans as reserve, and the capacity of structures in the formation of buds indicate the potential of herbaceous species of Asteraceae in forming a viable bud bank for vegetation regeneration in the Brazilian Cerrado.No Cerrado brasileiro (savana neotropical, o desenvolvimento de sistemas subterrâneos que produzem gemas, como estruturas adaptativas contra o fogo e períodos de seca, pode compreender um importante suprimento de gemas para esse ecossistema, como já demonstrado nos campos brasileiros e nas pradarias norte-americanas. Espécies de Asteraceae tanto do estrato lenhoso, quanto do herbáceo têm órgãos que acumulam carboidratos, reforçando a estratégia adaptativa dessas plantas a diferentes condições ambientais. Este estudo tem o objetivo de analisar a morfo

  10. Determination of respiratory system compliance during pressure support ventilation by small variations of pressure support.

    Science.gov (United States)

    Becher, Tobias; Schädler, Dirk; Rostalski, Philipp; Zick, Günther; Frerichs, Inéz; Weiler, Norbert

    2017-09-22

    In mechanically ventilated patients, measurement of respiratory system compliance (C rs ) is of high clinical interest. Spontaneous breathing activity during pressure support ventilation (PSV) can impede the correct assessment of C rs and also alter the true C rs by inducing lung recruitment. We describe a method for determination of C rs during PSV and assess its accuracy in a study on 20 mechanically ventilated patients. To assess C rs during pressure support ventilation (C rs,PSV ), we performed repeated changes in pressure support level by ± 2 cmH 2 O. C rs,PSV was calculated from the volume change induced by these changes in pressure support level, taking into account the inspiration time and the expiratory time constant. As reference methods, we used C rs , measured during volume controlled ventilation (C rs,VCV ). In a post-hoc analysis, we assessed C rs during the last 20% of the volume-controlled inflation (C rs,VCV20 ). Values were compared by linear regression and Bland-Altman methods comparison. Comparing C rs,PSV to the reference value C rs,VCV , we found a coefficient of determination (r 2 ) of 0.90, but a relatively high bias of - 7 ml/cm H 2 O (95% limits of agreement - 16.7 to + 2.7 ml/cmH 2 O). Comparison with C rs,VCV20 resulted in a negligible bias (- 1.3 ml/cmH 2 O, 95% limits of agreement - 13.9 to + 11.3) and r 2 of 0.81. We conclude that the novel method provides an estimate of end-inspiratory C rs during PSV. Despite its limited accuracy, it might be useful for non-invasive monitoring of C rs in patients undergoing pressure support ventilation.

  11. Mechanical Ventilation

    Science.gov (United States)

    ... ventilation is a life support treatment. A mechanical ventilator is a machine that helps people breathe when ... to breathe enough on their own. The mechanical ventilator is also called a ventilator , respirator, or breathing ...

  12. Natural ventilation systems to enhance sustainability in buildings: a review towards zero energy buildings in schools

    Science.gov (United States)

    Gil-Baez, Maite; Barrios-Padura, Ángela; Molina-Huelva, Marta; Chacartegui, Ricardo

    2017-11-01

    European regulations set the condition of Zero Energy Buildings for new buildings since 2020, with an intermediate milestone in 2018 for public buildings, in order to control greenhouse gases emissions control and climate change mitigation. Given that main fraction of energy consumption in buildings operation is due to HVAC systems, advances in its design and operation conditions are required. One key element for energy demand control is passive design of buildings. On this purpose, different recent studies and publications analyse natural ventilation systems potential to provide indoor air quality and comfort conditions minimizing electric power consumption. In these passive systems are of special relevance their capacities as passive cooling systems as well as air renovation systems, especially in high-density occupied spaces. With adequate designs, in warm/mild climates natural ventilation systems can be used along the whole year, maintaining indoor air quality and comfort conditions with small support of other heating/cooling systems. In this paper is analysed the state of the art of natural ventilation systems applied to high density occupied spaces with special focus on school buildings. The paper shows the potential and applicability of these systems for energy savings and discusses main criteria for their adequate integration in school building designs.

  13. Assessment of dynamic mechanical properties of the respiratory system during high-frequency oscillatory ventilation*.

    Science.gov (United States)

    Dellacà, Raffaele L; Zannin, Emanuela; Ventura, Maria L; Sancini, Giulio; Pedotti, Antonio; Tagliabue, Paolo; Miserocchi, Giuseppe

    2013-11-01

    1) To investigate the possibility of estimating respiratory system impedance (Zrs, forced oscillation technique) by using high-amplitude pressure oscillations delivered during high-frequency oscillatory ventilation; 2) to characterize the relationship between Zrs and continuous distending pressure during an increasing/decreasing continuous distending pressure trial; 3) to evaluate how the optimal continuous distending pressure identified by Zrs relates to the point of maximal curvature of the deflation limb of the quasi-static pressure-volume curve. Prospective laboratory animal investigation. Experimental medicine laboratory. Eight New Zealand rabbits. The rabbits were ventilated with high-frequency oscillatory ventilation. Zrs was measured while continuous distending pressure was increased and decreased between 2 and 26 cm H2O in 1-minute steps of 4 cm H2O. At each step, a low-amplitude (6 cm H2O) sinusoidal signal was alternated with a high-amplitude (18 cm H2O) asymmetric high-frequency oscillatory ventilation square pressure waveform. Pressure-volume curves were determined at the end of the continuous distending pressure trial. All measurements were repeated after bronchoalveolar lavage. Zrs was estimated from flow and pressure measured at the inlet of the tracheal tube and expressed as resistance (Rrs) and reactance (Xrs). Linear correlation between the values, measured by applying the small-amplitude sinusoidal signal and the ventilator waveform, was good for Xrs (r = 0.95 ± 0.04) but not for Rrs (r = 0.60 ± 0.34). Following lavage, the Xrs-continuous distending pressure curves presented a maximum on the deflation limb, identifying an optimal continuous distending pressure that was, on average, 1.1 ± 1.7 cm H2O below the point of maximal curvature of the deflation limb of the pressure-volume curves. Xrs can be accurately measured during high-frequency oscillatory ventilation without interrupting ventilation and/or connecting additional devices. An optimal

  14. Ventilator-derived dynamic respiratory system compliance: Comparison with static compliance in children.

    Science.gov (United States)

    Kaskinen, Anu K; Kirjavainen, Turkka; Rautiainen, Paula; Martelius, Laura; Andersson, Sture; Pitkänen, Olli M

    2018-02-01

    Measurement of dynamic lung compliance during breathing requires measurement of esophageal pressure, whereas static respiratory system compliance (Crs) method requires several airway occlusions. Despite their precision these compliance methods are cumbersome and not suitable for evaluation of pulmonary system in intensive care. The current ventilators display dynamic Crs, which, however, is seldom utilized in clinical practice. We studied the feasibility of ventilator-derived dynamic Crs measurement in pulmonary evaluation after congenital cardiac surgery in children. In 50 children static Crs was measured by double-occlusion technique, and compared with simultaneous ventilator-derived dynamic Crs values. The early postoperative dynamic and static Crs showed a correlation (r = 0.57, p static Crs was 48% higher than dynamic (p static Crs showed a negative correlation with radiographic lung edema scoring (r = -0.50, p = 0.0002). Thus ventilator-derived dynamic Crs seems less reliable in postoperative pulmonary evaluation than static Crs. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Energy Performance of a Novel System Combining Natural Ventilation with Diffuse Ceiling Inlet and Thermally Activated Building Systems (TABS)

    DEFF Research Database (Denmark)

    Yu, Tao

    . Both steady-state and dynamic measurements are carried out in the experimental chamber to investigate the energy performance of the system and the thermal comfort in the test room. Overall, this integrated system has high energy saving potential without any compromise of thermal comfort even in extreme...... and thermally activated building systems (TABS) for cooling and ventilation in future Danish office buildings. The new solution would have the special potential of using natural ventilation all year round even in the extremely cold seasons without any draught risk. The main focuses of this study are the energy...

  16. Definition and means of maintaining the ventilation system confinement portion of the PFP safety envelope

    Energy Technology Data Exchange (ETDEWEB)

    Dick, J.D.; Grover, G.A.; O`Brien, P.M., Fluor Daniel Hanford

    1997-03-05

    The Plutonium Finishing Plant Heating Ventilation and Cooling system provides for the confinement of radioactive releases to the environment and provides for the confinement of radioactive contamination within designated zones inside the facility. This document identifies the components and procedures necessary to ensure the HVAC system provides these functions. Appendices E through J provide a snapshot of non-safety class HVAC equipment and need not be updated when the remainder of the document and Appendices A through D are updated.

  17. Design and operating technique for ventilating system of irradiated materials examination facility

    International Nuclear Information System (INIS)

    Hwang, Yong Hwa; Hong, Kwon Pyo; Eom, Sung Ho

    1999-08-01

    Ventilation and air filtering system is installed at IMEF to maintain optimized operating condition of the facility by keeping different negative pressure condition depending on contamination level in the IMEF due to its treatment of radioactive materials. Inspection on each system, air flow measurement, filter leak test and other related test are periodically performed as the performance test for increasing operational efficiency and safety. (Author). 16 refs., 21 tabs., 9 figs

  18. Advanced Hybrid Spacesuit Concept Featuring Integrated Open Loop and Closed Loop Ventilation Systems

    Science.gov (United States)

    Daniel, Brian A.; Fitzpatrick, Garret R.; Gohmert, Dustin M.; Ybarra, Rick M.; Dub, Mark O.

    2013-01-01

    A document discusses the design and prototype of an advanced spacesuit concept that integrates the capability to function seamlessly with multiple ventilation system approaches. Traditionally, spacesuits are designed to operate both dependently and independently of a host vehicle environment control and life support system (ECLSS). Spacesuits that operate independent of vehicle-provided ECLSS services must do so with equipment selfcontained within or on the spacesuit. Suits that are dependent on vehicle-provided consumables must remain physically connected to and integrated with the vehicle to operate properly. This innovation is the design and prototype of a hybrid spacesuit approach that configures the spacesuit to seamlessly interface and integrate with either type of vehicular systems, while still maintaining the ability to function completely independent of the vehicle. An existing Advanced Crew Escape Suit (ACES) was utilized as the platform from which to develop the innovation. The ACES was retrofitted with selected components and one-off items to achieve the objective. The ventilation system concept was developed and prototyped/retrofitted to an existing ACES. Components were selected to provide suit connectors, hoses/umbilicals, internal breathing system ducting/ conduits, etc. The concept utilizes a lowpressure- drop, high-flow ventilation system that serves as a conduit from the vehicle supply into the suit, up through a neck seal, into the breathing helmet cavity, back down through the neck seal, out of the suit, and returned to the vehicle. The concept also utilizes a modified demand-based breathing system configured to function seamlessly with the low-pressure-drop closed-loop ventilation system.

  19. MODELLING AND SIMULATION OF A SINGLE-ZONE HEATING AND VENTILATION SYSTEM

    Directory of Open Access Journals (Sweden)

    Mesut ŞENGİRGİN

    2005-03-01

    Full Text Available In this study, modelling and simulation results of a single-zone heating and ventilation system of a large office room are introduced. Heating system is controlled by an on-off controller. By considering the sinusoidal outdoor air tempareture variation and various outdoor/return air ratios as input parameters, dynamic behaviour of room air tempereture are investigated. For this purpose, MATLAB/Simulink code is used.

  20. Alternative ventilation system for operating theaters: parameter study and full-scale assessment of the performance of a local ventilation system

    NARCIS (Netherlands)

    J.G.H. Loogman; Dr. H.S.M. Kort; M.G.L.C. Loomans; I.M. de Visser

    2016-01-01

    A local operating theater ventilation device to specifically ventilate the wound area has been developed and investigated. The ventilation device is combined with a blanket which lies over the patient during the operation. Two configurations were studied: Configuration 1 where HEPA-filtered air was

  1. A novel simulator for mechanical ventilation in newborns: MEchatronic REspiratory System SImulator for Neonatal Applications.

    Science.gov (United States)

    Baldoli, Ilaria; Cuttano, Armando; Scaramuzzo, Rosa T; Tognarelli, Selene; Ciantelli, Massimiliano; Cecchi, Francesca; Gentile, Marzia; Sigali, Emilio; Laschi, Cecilia; Ghirri, Paolo; Menciassi, Arianna; Dario, Paolo; Boldrini, Antonio

    2015-08-01

    Respiratory problems are among the main causes of mortality for preterm newborns with pulmonary diseases; mechanical ventilation provides standard care, but long-term complications are still largely reported. In this framework, continuous medical education is mandatory to correctly manage assistance devices. However, commercially available neonatal respiratory simulators are rarely suitable for representing anatomical and physiological conditions; a step toward high-fidelity simulation, therefore, is essential for nurses and neonatologists to acquire the practice needed without any risk. An innovative multi-compartmental infant respirator simulator based on a five-lobe model was developed to reproduce different physio-pathological conditions in infants and to simulate many different kinds of clinical scenarios. The work consisted of three phases: (1) a theoretical study and modeling phase, (2) a prototyping phase, and (3) testing of the simulation software during training courses. The neonatal pulmonary simulator produced allows the replication and evaluation of different mechanical ventilation modalities in infants suffering from many different kinds of respiratory physio-pathological conditions. In particular, the system provides variable compliances for each lobe in an independent manner and different resistance levels for the airway branches; moreover, it allows the trainer to simulate both autonomous and mechanically assisted respiratory cycles in newborns. The developed and tested simulator is a significant contribution to the field of medical simulation in neonatology, as it makes it possible to choose the best ventilation strategy and to perform fully aware management of ventilation parameters. © IMechE 2015.

  2. Personalized ventilation

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2004-01-01

    The thermal environment and air quality in buildings affects occupants' health, comfort and performance. The heating, ventilating and air-conditioning (HVAC) of buildings today is designed to provide a uniform room environment. However, large individual differences exist between occupants in regard...... microenvironment. Furthermore, HVAC systems should be designed to protect occupants from airborne transmission of infectious agents that may be present in exhaled air. Personalized ventilation is a new development in the field of HVAC and has the potential to fulfill the above requirements. This paper reviews...... existing knowledge on performance of personalized ventilation (PV) and on human response to it. The airflow interaction in the vicinity of the human body is analyzed and its impact on thermal comfort and inhaled air quality is discussed together with control strategies and the application of PV in practice...

  3. Performance of a demand controlled mechanical extract ventilation system for dwellings

    Directory of Open Access Journals (Sweden)

    I. Pollet

    2013-10-01

    Full Text Available The main aim of ventilation is to guarantee a good indoor air quality, related to the energy consumed for heating and fan(s. Active or passive heat recovery systems seem to focus on the reduction of heating consumption at the expense of fan electricity consumption and maintenance. In this study, demandcontrolled mechanical extract ventilation systems of Renson (DCV1 and DCV2, based on natural supply in the habitable rooms and mechanical extraction in the wet rooms (or even the bedrooms, was analysed for one year by means of multi-zone Contam simulations on a reference detached house and compared with standard MEV and mechanical extract ventilation systems with heat recovery (MVHR. To this end, IAQ, total energy consumption, CO2 emissions and total cost of the systems are determined. The results show that DCV systems with increased supply air flow rates or direct mechanical extract from bedrooms can significantly improve IAQ, while reducing total energy consumption compared to MEV. Applying DCV reduces primary heating energy consumption and yearly fan electricity consumption at most by 65% to 50% compared to MEV. Total operational energy costs and CO2 emissions of DCV are similar when compared to MVHR. Total costs of DCV systems over 15 years are smaller when compared to MVHR due to lower investment and maintenance costs.

  4. Energy saving effect of desiccant ventilation system using Wakkanai siliceous shale

    Science.gov (United States)

    Nabeshima, Yuki; Togawa, Jun-ya; Nagano, Katsunori; Kazuyo, Tsuzuki

    2017-10-01

    The nuclear power station accident resulting from the Great East Japan Earthquake disaster has resulted in a constrained electricity supply. However, in this Asian region there is high temperature and high humidity and consequently dehumidification process requires a huge amount of energy. This is the reason for the increasing energy consumption in the residential and commercial sectors. Accordingly, a high efficiency air-conditioning system is needed to be developed. The desiccant ventilation system is effective to reduce energy consumption for the dehumidification process. This system is capable of dehumidifying without dew condensing unlike a conventional air-conditioning system. Then we focused on Wakkanai Siliceous Shale (WSS) as a desiccant material to develop a new desiccant ventilation system. This is low priced, high performance, new type of thing. The aim of this study is to develop a desiccant ventilation unit using the WSS rotor which can be regenerated with low-temperature by numerical calculation. The results of performance prediction of the desiccant unit, indicate that it is possible to regenerate the WSS rotor at low-temperature of between 35 - 45 °C. In addition, we produced an actual measurement for the desiccant unit and air-conditioning unit. This air-conditioning system was capable to reduce roughly 40 % of input energy consumption.

  5. Development of a 3D Underground Cadastral System with Indoor Mapping for As-Built BIM: The Case Study of Gangnam Subway Station in Korea.

    Science.gov (United States)

    Kim, Sangmin; Kim, Jeonghyun; Jung, Jaehoon; Heo, Joon

    2015-12-09

    The cadastral system provides land ownership information by registering and representing land boundaries on a map. The current cadastral system in Korea, however, focuses mainly on the management of 2D land-surface boundaries. It is not yet possible to provide efficient or reliable land administration, as this 2D system cannot support or manage land information on 3D properties (including architectures and civil infrastructures) for both above-ground and underground facilities. A geometrical model of the 3D parcel, therefore, is required for registration of 3D properties. This paper, considering the role of the cadastral system, proposes a framework for a 3D underground cadastral system that can register various types of 3D underground properties using indoor mapping for as-built Building Information Modeling (BIM). The implementation consists of four phases: (1) geometric modeling of a real underground infrastructure using terrestrial laser scanning data; (2) implementation of as-built BIM based on geometric modeling results; (3) accuracy assessment for created as-built BIM using reference points acquired by total station; and (4) creation of three types of 3D underground cadastral map to represent underground properties. The experimental results, based on indoor mapping for as-built BIM, show that the proposed framework for a 3D underground cadastral system is able to register the rights, responsibilities, and restrictions corresponding to the 3D underground properties. In this way, clearly identifying the underground physical situation enables more reliable and effective decision-making in all aspects of the national land administration system.

  6. Development of a 3D Underground Cadastral System with Indoor Mapping for As-Built BIM: The Case Study of Gangnam Subway Station in Korea

    Directory of Open Access Journals (Sweden)

    Sangmin Kim

    2015-12-01

    Full Text Available The cadastral system provides land ownership information by registering and representing land boundaries on a map. The current cadastral system in Korea, however, focuses mainly on the management of 2D land-surface boundaries. It is not yet possible to provide efficient or reliable land administration, as this 2D system cannot support or manage land information on 3D properties (including architectures and civil infrastructures for both above-ground and underground facilities. A geometrical model of the 3D parcel, therefore, is required for registration of 3D properties. This paper, considering the role of the cadastral system, proposes a framework for a 3D underground cadastral system that can register various types of 3D underground properties using indoor mapping for as-built Building Information Modeling (BIM. The implementation consists of four phases: (1 geometric modeling of a real underground infrastructure using terrestrial laser scanning data; (2 implementation of as-built BIM based on geometric modeling results; (3 accuracy assessment for created as-built BIM using reference points acquired by total station; and (4 creation of three types of 3D underground cadastral map to represent underground properties. The experimental results, based on indoor mapping for as-built BIM, show that the proposed framework for a 3D underground cadastral system is able to register the rights, responsibilities, and restrictions corresponding to the 3D underground properties. In this way, clearly identifying the underground physical situation enables more reliable and effective decision-making in all aspects of the national land administration system.

  7. Designing, Constructing and Installing a Local Exhaust Ventilation System to Minimize Welders\\' Exposure to Welding Fumes

    Directory of Open Access Journals (Sweden)

    Sajad Zare

    2017-10-01

    Full Text Available Background & Aims of the Study: Welder’s exposure to welding fumes can cause occupational diseases. The current study sought to examine exposure to welding fumes among welders who work in the repair shop of Sarcheshmeh Copper Complex and design a local exhaust ventilation system to control exposure to welding fumes. Materials & Methods: This applied analytical study was conducted in the summer of 2016 among welders working in the repair shop of Sarcheshmeh Copper Complex. The study comprised three phases; in the first one, welders’ exposure to welding fumes was assessed at the beginning of the study. After that, a local exhaust ventilation system was designed and installed in the aforementioned repair shop. In the final stage, welders’ exposure to welding fumes was assessed again after installation of the ventilation system. The procedure recommended by NIOSH (method number 7300 was used for individual sampling of welders. Results: Based on the obtained findings, before installing the ventilation system, welding technicians were exposed to 0.3 mg/m3 of copper fumes and 0.04 mg/m3 of chromium fumes. Journeyman welders were also exposed to 2.16 mg/m3 of manganese fumes, while stellar welders were exposed to 6.9 mg/m3 of iron fumes. In the light of these measurements, a local exhaust ventilation system was designed and installed. Subsequently, measurement of exposure to welding fumes showed a significant reduction. That is, welding technicians were exposed to 0.17 mg/m3 and 0.015 mg/m3 of copper and chromium fumes respectively. Additionally, journeyman welders were exposed to 0.86 mg/m3 of manganese fumes, whereas stellar welders were exposed to 4.3 mg/m3 of iron fumes. Conclusions: A comparison of standard limits of exposure to welding fumes and the results obtained from measurements in sampling stations before and after the installation of the local exhaust ventilation system reveals that this controlling measure was very effective in the

  8. Control System Implementation and Follow-up within the Cooling and Ventilation Contracts for the LHC

    CERN Document Server

    Body, Y; Morodo, M C

    2001-01-01

    The control system implementation for the cooling and ventilation facilities connected to the LHC Project relies on the technical and human resources that are organised within large-size industrial contracts. Beside the technical aspects, the follow-up of the implementation activities in the framework of such contracts also involves a managerial effort in order to achieve a flexible and coherent control system. The purpose is to assure precise and reliable regulation together with accurate local and remote supervision in conformity with the operational requirements. These objectives can only be reached by a systematic approach that keeps the co-ordination between the in-house and external cross-disciplinary teams as well as the fulfilment of the validation procedures and the contractual formalities. The case that here illustrates this approach is the control system implementation for the heating, ventilation and air conditioning of the LHC surface buildings, which shall extend up to 2004.

  9. [Reducing the levels of formaldehyde exposure during a gross anatomy dissection course with a local ventilation system].

    Science.gov (United States)

    Kikuta, Akio; Yamato, Hiroshi; Kunugita, Naoki; Nakashima, Tamiji; Hayashi, Haruki

    2010-03-01

    Reducing the levels of formaldehyde (FA) exposure in gross anatomy laboratories has been urgently required. We improved the environment of our gross anatomy laboratory by changing the existing general ventilation to local ventilation. We developed a local ventilation apparatus (grid-type of hood with downward suction) that can be attached to an ordinary dissection table. Furthermore, in order to make this local ventilation apparatus an enclosure hood, the upper plate of the dissection table was surrounded by flexible vertical flanges. The apparatus works as an effective enclosure hood without interfering with students' practice of dissection. We installed 26 local ventilation apparatuses and connected them to the ventilation duct. The ventilation ducts were installed above the ceiling or along the pillars not to interfere with students' vision and movements in the room. Adopting the local ventilation system reduced dramatically the students' and lecturers' exposure to formaldehyde. The geometric mean formaldehyde concentration was 0.066 ppm in the anatomy laboratory in 2005. Since 2005, the new system has enabled us to comply with safety and health regulations and providing a smell- and irritant-free dissection room with an excellent environment for anatomy study.

  10. Enhancement of organizational and technical solutions regarding anchoring of completed construction facilities of underground railway system to operating control

    OpenAIRE

    Е. Г. Козин

    2017-01-01

    Stages of practical realization of measures prescribed by requirements documents regarding anchoring of capital structures of underground railway system to operating control are considered in the article. On the basis of algorithm structure analysis, which includes obtaining a permit for putting into operation and cadastre works execution a range of solutions was proposed concerning optimization of construction project owner and operating organization activities with the purpose of terms redu...

  11. On the thermal interaction of building structure and heating and ventilation system

    Science.gov (United States)

    Hensen, Joannes Laurentius Maria

    Developments in the field of building performance evaluation tools for thermal interaction of building structure and heating and ventilating systems are described. The technique employed is computer simulation of the integrated dynamic system comprising the occupants, the building and its heating and ventilating system. Assessment criteria from a literature review in thermal comfort to examine acceptable fluctuations in indoor climate are defined. Building and plant energy simulation within the context of Computer Aided Building Design (CABD) is described. An exisiting energy simulation environment ESP(R) (Environmental Systems Performance (Research version)) is chosen. A fluid flow network simulation module is described. Extensions to ESP(R) to predict the dynamic behavior of the heating and ventilation system are described. The coupling of fluid flow, plant side energy and mass, and building side energy simulation into one integrated program is described. A multistage verification and validation methodology is demonstrated by examples addressing each successive step. Imaginary and real world cases are described to demonstrate application of the study in a modeling orientated and a building engineering context.

  12. Ventilation systems analysis during tornado conditions. Progress report, July--December 1975

    International Nuclear Information System (INIS)

    Gregory, W.S.; Duerre, K.H.; Bennett, G.A.

    1976-04-01

    A review of some existing digital simulations of fluid systems, a brief description of the proposed generalized computer code, a description of, and results from, two solution techniques, and a sample test case ventilation system are presented. The review of some fluid system simulations covers methods and techniques for development of a more general digital solution technique than the successive substitution method used in previous analyses. The structure and organization of the computer code under development is discussed. A section dealing with the development of a user-oriented input to the code is also presented. Two solution techniques suitable for solving the simultaneous nonlinear algebraic and differential equations are presented. One of the techniques is based upon a loop method and employs Newton's method for obtaining simultaneous iterative corrections for the solution. The second approach is based upon a node orientation and employs Cross' method to arrive at successive iterative corrections for the solution. Graphical results using both methods are presented. The results are essentially identical. A ''test-case'' ventilation system is introduced. The test-case ventilation system model was developed primarily for ''debugging'' the proposed generalized code. The test case is a simple yet realistic representation of the types of subsystems which could be encountered in nuclear facilities

  13. Clinical validation of the Deltatrac monitoring system in mechanically ventilated patients.

    Science.gov (United States)

    Tissot, S; Delafosse, B; Bertrand, O; Bouffard, Y; Viale, J P; Annat, G

    1995-02-01

    To evaluate a monitor of pulmonary gas exchange (Deltatrac, Datex) in a clinical setting. After in vitro evaluation, comparison over 2 min between VO2 and VCO2 values measured by the Deltatrac and the Douglas bag technique. Comparisons were also achieved over 8 h periods between the Deltatrac and a system using a mass-spectrometer. Polyvalent intensive care unit (ICU 15 beds) in a 1200 bed general hospital. Comparison with the Douglas bag technique in 10 patients undergoing controlled ventilation. Comparison with the mass-spectrometer system in 25 other patients undergoing controlled or pressure support ventilation. Compared to the results obtained by the Douglas bag technique, the bias (+/- 2 SD) for VO2 and VCO2 was -3.5 +/- 26.6 and 6.1 +/- 12.7 ml.min-1, respectively. By comparison with the mass-spectrometer system, the bias for VO2 and RQ was -5.8 +/- 16.0 ml.min-1 and 0.018 +/- 0.048, respectively. No drift between the two systems was observed over time. The Deltatrac appears suitable for VO2 and VCO2 measurements in ventilated patients and equivalent to a mass-spectrometer system for long term measurements.

  14. Modelling of radon control and air cleaning requirements in underground uranium mines

    International Nuclear Information System (INIS)

    El Fawal, M.; Gadalla, A.

    2014-01-01

    As a part of a comprehensive study concerned with control workplace short-lived radon daughter concentration in underground uranium mines to safe levels, a computer program has been developed and verified, to calculate ventilation parameters e.g. local pressures, flow rates and radon daughter concentration levels. The computer program is composed of two parts, one part for mine ventilation and the other part for radon daughter levels calculations. This program has been validated in an actual case study to calculate radon concentration levels, pressure and flow rates required to maintain acceptable levels of radon concentrations in each point of the mine. The required fan static pressure and the approximate energy consumption were also estimated. The results of the calculations have been evaluated and compared with similar investigation. It was found that the calculated values are in good agreement with the corresponding values obtained using ''REDES'' standard ventilation modelling software. The developed computer model can be used as an available tool to help in the evaluation of ventilation systems proposed by mining authority, to assist the uranium mining industry in maintaining the health and safety of the workers underground while efficiently achieving economic production targets. It could be used also for regulatory inspection and radiation protection assessments of workers in the underground mining. Also with using this model, one can effectively design, assess and manage underground mine ventilation systems. Values of radon decay products concentration in units of working level, pressures drop and flow rates required to reach the acceptable radon concentration relative to the recommended levels, at different extraction points in the mine and fan static pressure could be estimated which are not available using other software. (author)

  15. Design of the natural ventilation system for the new San Diego Children's Museum

    Energy Technology Data Exchange (ETDEWEB)

    Graca, G.C. [Natural Works Inc., CA (United States); Linden, P.F. [California Univ., San Diego, CA (United States). Dept. of Mechanical and Aerospace Engineering; Brook, M. [California Energy Commission, Sacramento, CA (United States)

    2005-07-01

    One of the unique features of the newly designed San Diego Children's museum is the solar chimney that is expected to promote buoyancy-driven flow that would come into the space through large, user-controlled roll up doors on the south facade. As part of a sustainable design choice, the proposed museum exhibition space will not have any mechanical heating or cooling systems. Indoor temperatures will be controlled using ventilation air using a variable air volume principle driven by wind and buoyancy. The ventilation system inserts fresh outside air at low levels and exhausts at higher levels achieving displacement ventilation. Particular attention was given to defining the shape of the outlet from the chimney in order to maximize wind-induced suction effects in the outlet surface. A building management system (BMS) and a control strategy were developed to optimize the performance of the building. The tools used in the analysis were a specifically designed weather analysis spreadsheet, EnergyPlus with COMIS and computational fluid dynamics. This study of the passive climate control system also involved an analysis of weather characteristics; analysis of the different glazing, chimney geometries and roof insulation; refining existing window opening geometry and positions; defining window opening control strategies. It was concluded that it is possible to improve the chimney performance by using a high level opening on the East side. Additional gains can be obtained by inserting a small opening facing North. 5 refs., 5 tabs., 10 figs.

  16. A versatile hydraulically operated respiratory servo system for ventilation and lung function testing.

    Science.gov (United States)

    Meyer, M; Slama, H

    1983-09-01

    A description is given of the design and performance of a microcomputer-controlled respiratory servo system that incorporates the characteristics of a mechanical ventilator and also allows the performance of a multitude of test procedures required for assessment of pulmonary function in paralyzed animals. The device consists of a hydraulically operated cylinder-piston assembly and solenoid valves that direct inspiratory and expiratory gas flow and also enable switching to different test gas sources. The system operates as a volume-flow-preset ventilator but may be switched to other operational cycling modes. Gas flow rates may be constant or variable. The system operates as an assister-controller and, combined with a gas analyzer, can function as a "demand" ventilator allowing for set-point control of end-tidal PCO2 and PO2. Complex breathing maneuvers for a variety of single- and multiple-breath lung function tests are automatically performed. Because of the flexibility in selection and timing of respiratory parameters, the system is particularly suitable for respiratory gas studies.

  17. Analysis of ventilation systems subjected to explosive transients: initial analysis and proposed approach

    International Nuclear Information System (INIS)

    Gregory, W.S.; Smith, P.R.; Bolstad, J.W.; Duerre, K.H.

    1979-08-01

    This report describes an initial study of explosive pressure transients and their propagation through ventilation systems. The objective of this study is to organize the required calculations into a computer code that is highly user-oriented and will predict explosive-induced gas dynamics within a ventilation system. The explosive process is subdivided into three regimes - deflagration, detonation, and transition from deflagration to detonation. Equations describing each process and suggested procedures for solving these equations are presented. The proposed organization of the explosion code capitalizes on the desirable aspects of the previously developed TVENT code, which predicts tornado-induced pressure transients within ventilation systems. The explosion code will include both near- and far-field analyses. The near-field analysis will use detailed models to describe the combustion process near the explosive event, and provide parametric driving potentials for flow in the regions that are removed from the explosive event (far-field). The far-field analysis will include the combustion wave as it propagates through the rest of the system

  18. Active Fault Tolerant Control of Livestock Stable Ventilation System

    DEFF Research Database (Denmark)

    Gholami, Mehdi

    2011-01-01

    degraded performance even in the faulty case. In this thesis, we have designed such controllers for climate control systems for livestock buildings in three steps: Deriving a model for the climate control system of a pig-stable. Designing a active fault diagnosis (AFD) algorithm for different kinds...... of the hybrid model are estimated by a recursive estimation algorithm, the Extended Kalman Filter (EKF), using experimental data which was provided by an equipped laboratory. Two methods for active fault diagnosis are proposed. The AFD methods excite the system by injecting a so-called excitation input. In both...... methods, the input is designed off-line based on a sensitivity analysis in order to improve the precision of estimation of parameters associated with faults. Two different algorithm, the EKF and a new adaptive filter, are used to estimate the parameters of the system. The fault is detected and isolated...

  19. Cost optimization for buildings with hybrid ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Kun; Lu, Yan

    2018-02-13

    A method including: computing a total cost for a first zone in a building, wherein the total cost is equal to an actual energy cost of the first zone plus a thermal discomfort cost of the first zone; and heuristically optimizing the total cost to identify temperature setpoints for a mechanical heating/cooling system and a start time and an end time of the mechanical heating/cooling system, based on external weather data and occupancy data of the first zone.

  20. Use of geostatistics on broiler production for evaluation of different minimum ventilation systems during brooding phase

    Directory of Open Access Journals (Sweden)

    Thayla Morandi Ridolfi de Carvalho

    2012-01-01

    Full Text Available The objective of this research was to evaluate different minimum ventilation systems, in relation to air quality and thermal comfort using geostatistics in brooding phase. The minimum ventilation systems were: Blue House I: exhaust fans + curtain management (end of the building; Blue House II: exhaust fans + side curtain management; and Dark House: exhaust fans + flag. The climate variables evaluated were: dry bulb temperature, relative humidity, air velocity, carbon dioxide and ammonia concentration, during winter time, at 9 a.m., in 80 equidistant points in brooding area. Data were evaluated by geostatistic technique. The results indicate that Wider broiler houses (above 15.0 m width present the greatest ammonia and humidity concentration. Blue House II present the best results in relation to air quality. However, none of the studied broiler houses present an ideal thermal comfort.

  1. Ventilator Data Extraction with a Video Display Image Capture and Processing System.

    Science.gov (United States)

    Wax, David B; Hill, Bryan; Levin, Matthew A

    2017-06-01

    Medical hardware and software device interoperability standards are not uniform. The result of this lack of standardization is that information available on clinical devices may not be readily or freely available for import into other systems for research, decision support, or other purposes. We developed a novel system to import discrete data from an anesthesia machine ventilator by capturing images of the graphical display screen and using image processing to extract the data with off-the-shelf hardware and open-source software. We were able to successfully capture and verify live ventilator data from anesthesia machines in multiple operating rooms and store the discrete data in a relational database at a substantially lower cost than vendor-sourced solutions.

  2. EVALUATION OF BEST AVAILABLE CONTROL TECHNOLOGY FOR TOXICS (TBACT) DOUBLE SHELL TANK FARMS PRIMARY VENTILATION SYSTEMS SUPPORTING WASTE TRANSFER OPERATIONS

    International Nuclear Information System (INIS)

    Haas, C.C.; Kovach, J.L.; Kelly, S.E.; Turner, D.A.

    2010-01-01

    This report is an evaluation of Best Available Control Technology for Toxics (tBACT) for installation and operation of the Hanford double shell (DST) tank primary ventilation systems. The DST primary ventilation systems are being modified to support Hanford's waste retrieval, mixing, and delivery of single shell tank (SST) and DST waste through the DST storage system to the Waste Treatment and Immobilization Plant (WTP).

  3. EVALUATION OF BEST AVAILABLE CONTROL TECHNOLOGY FOR TOXICS -TBACT- DOUBLE SHELL TANK FARMS PRIMARY VENTILATION SYSTEMS SUPPORTING WASTE TRANSFER OPERATIONS

    Energy Technology Data Exchange (ETDEWEB)

    HAAS CC; KOVACH JL; KELLY SE; TURNER DA

    2010-06-24

    This report is an evaluation of Best Available Control Technology for Toxics (tBACT) for installation and operation of the Hanford double shell (DST) tank primary ventilation systems. The DST primary ventilation systems are being modified to support Hanford's waste retrieval, mixing, and delivery of single shell tank (SST) and DST waste through the DST storage system to the Waste Treatment and Immobilizaiton Plant (WTP).

  4. EVALUATION OF BEST AVAILABLE CONTROL TECHNOLOGY FOR TOXICS (TBACT) DOUBLE SHELL TANK FARMS PRIMARY VENTILATION SYSTEM SUPPORTING WASTE TRANSFER OPERATIONS

    Energy Technology Data Exchange (ETDEWEB)

    KELLY SE; HAASS CC; KOVACH JL; TURNER DA

    2010-06-03

    This report is an evaluation of Best Available Control Technology for Toxics (tBACT) for installation and operation of the Hanford double shell (DST) tank primary ventilation systems. The DST primary ventilation systems are being modified to support Hanford's waste retrieval, mixing, and delivery of single shell tank (SST) and DST waste throught the DST storage system to the Waste Treatment and Immobilization Plant (WTP).

  5. EVALUATION OF BEST AVAILABLE CONTROL TECHNOLOGY FOR TOXICS (TBACT) DOUBLE SHELL TANK FARMS PRIMARY VENTILATION SYSTEM SUPPORTING WASTE TRANSFER OPERATIONS

    International Nuclear Information System (INIS)

    Kelly, S.E.; Haass, C.C.; Kovach, J.L.; Turner, D.A.

    2010-01-01

    This report is an evaluation of Best Available Control Technology for Toxics (tBACT) for installation and operation of the Hanford double shell (DST) tank primary ventilation systems. The DST primary ventilation systems are being modified to support Hanford's waste retrieval, mixing, and delivery of single shell tank (SST) and DST waste through out the DST storage system to the Waste Treatment and Immobilization Plant (WTP).

  6. Identification of underground mine workings with the use of global positioning system technology

    Energy Technology Data Exchange (ETDEWEB)

    Canty, G.A.; Everett, J.W. [Univ. of Oklahoma, Norman, OK (United States). Dept. of Civil Engineering and Environmental Science; Sharp, M. [Oklahoma Conservation Commission, Oklahoma City, OK (United States). Abandoned Mine Land Reclamation Program

    1998-12-31

    Identification of underground mine workings for well drilling is a difficult task given the limited resources available and lack of reliable information. Relic mine maps of questionable accuracy and difficulty in correlating the subsurface to the surface, make the process of locating wells arduous. With the development of global positioning system (GPS), specific locations on the earth can be identified with the aid of satellites. This technology can be applied to mine workings identification given a few necessary, precursory details. For an abandoned mine treatment project conducted by the University of Oklahoma, in conjunction with the Oklahoma Conservation Commission, a Trimble ProXL 8 channel GPS receiver was employed to locate specific points on the surface with respect to a mine map. A 1925 mine map was digitized into AutoCAD version 13 software. Surface features identified on the map, such as mine adits, were located and marked in the field using the GPS receiver. These features were than imported into AutoCAD and referenced with the same points drawn on the map. A rubber sheeting program, Multric, was used to tweak the points so the map features correlated with the surface points. The correlation of these features allowed the map to be geo-referenced with the surface. Specific drilling points were located on the digitized map and assigned a latitude and longitude. The GPS receiver, using real time differential correction, was used to locate these points in the field. This method was assumed to be relatively accurate, to within 5 to 15 feet.

  7. Identification of underground mine workings with the use of global positioning system technology

    International Nuclear Information System (INIS)

    Canty, G.A.; Everett, J.W.; Sharp, M.

    1998-01-01

    Identification of underground mine workings for well drilling is a difficult task given the limited resources available and lack of reliable information. Relic mine maps of questionable accuracy and difficulty in correlating the subsurface to the surface, make the process of locating wells arduous. With the development of global positioning system (GPS), specific locations on the earth can be identified with the aid of satellites. This technology can be applied to mine workings identification given a few necessary, precursory details. For an abandoned mine treatment project conducted by the University of Oklahoma, in conjunction with the Oklahoma Conservation Commission, a Trimble ProXL 8 channel GPS receiver was employed to locate specific points on the surface with respect to a mine map. A 1925 mine map was digitized into AutoCAD version 13 software. Surface features identified on the map, such as mine adits, were located and marked in the field using the GPS receiver. These features were than imported into AutoCAD and referenced with the same points drawn on the map. A rubber sheeting program, Multric, was used to tweak the points so the map features correlated with the surface points. The correlation of these features allowed the map to be geo-referenced with the surface. Specific drilling points were located on the digitized map and assigned a latitude and longitude. The GPS receiver, using real time differential correction, was used to locate these points in the field. This method was assumed to be relatively accurate, to within 5 to 15 feet

  8. SIMULATION OF FREE CURRENT FLOWS IN BUOYANCY-DRIVEN VENTILATION SYSTEMS

    Directory of Open Access Journals (Sweden)

    D. V. Abramkina

    2017-01-01

    Full Text Available Objectives. The aim of the study is to analyse the effect of the design and methods for heating the ventilation duct of a buoyancy- driven system on the formation of free convective air currents in it.Methods. The study of free convection under the conditions of interior problem was carried out using the CFD software, based on  the finite volume method with unstructured grid. Ansys Fluent software was used as a calculation tool in the study, due to its having a high convergence of numerical solutions offering full-scale  measurements of convective currents.To evaluate the reliability of  the results obtained, a validation procedure was carried out, allowing us to determine how accurately the selected conceptual model describes the investigated flow through a comparison of experimental and numerical data.Results. The results of numerical modelling of free convective currents occurring in the heated channel of the ventilation system of  the top floor of a multi-storey residential building are presented in  the article. In the course of the study, the air velocity at the entrance to the ventilation duct was found to depend on the calculated  temperature difference θ ˚C for various heating methods. A gradual  increase in the discrepancy between the numerical simulation and  experimental results is observed if the calculated temperature  difference > 20 ° C. This phenomenon is due to the fact that with  increased duct temperature, it is quite difficult to achieve even  heating under actual conditions; this is especially noticeable when  considering the variant when the vertical part of the vent duct and the take-off are both heated. The maximum deviation of the  results is 4.4%. The obtained velocity profiles in the calculated  sections indicate the impact of the ventilation take-off on the nature  of the air flow motion.Conclusion. One of the drawbacks of the existing systems of natural ventilation of residential

  9. Use of VOC sensors for air quality control of building ventilation systems

    OpenAIRE

    Großklos, M.

    2015-01-01

    Air quality control with VOC (volatile organic compound) sensors in residential buildings could increase user comfort by adapting to the actual contaminant level. Preliminary tests assessed the dynamics of VOC levels in single-family passive houses with a ventilation system. At normal and exceptional usages, sufficient signal variations were measured for air quality control. An air quality control was developed and tested in four single-family passive house dwellings to cont...

  10. Plan of action for quality improvement of ventilation systems; Actieplan Kwaliteitsverbetering Ventilatievoorzieningen

    Energy Technology Data Exchange (ETDEWEB)

    Atsma, J. [Ministerie van Infrastructuur en Milieu IenM, Den Haag (Netherlands); Calon, M. [Aedes vereniging van woningcorporaties, Den Haag (Netherlands); Schoorl, F.J. [Bond Nederlandse Architecten BNA, Amsterdam (Netherlands); Van Tuinen, J.L. [Bouwend Nederland, Zoetermeer (Netherlands); Bodewes, W.J. [Vereniging van Nederlandse projectontwikkeling Maatschappijen Neprom, Voorburg (Netherlands); Goossens, J.H. [Vereniging voor ontwikkelaars en bouwondernemers NVB, Voorburg (Netherlands); Polman, E.J.M. [Stichting Waarborgfonds Koopwoningen SWK, Rotterdam (Netherlands); Engels, M. [Uneto-VNI, Zoetermeer (Netherlands); Werner-van Beek, H. J. [VACpunt Wonen, Utrecht (Netherlands); Mulder, R.J. [Vereniging Eigen Huis VEH, Amersfoort (Netherlands); Rook, G. [Vereniging Leveranciers van Luchttechnische Apparaten VLA, Zoetermeer (Netherlands); Van Noord, P. [Woningborg, Gouda (Netherlands); Paping, R.H.M. [De Nederlandse Woonbond, Amsterdam (Netherlands)

    2012-06-15

    The action plan comprises the agreements made by the Ministry of Infrastructure and Environment and the Ministry of Internal Affairs in the Netherlands with representatives of building organizations to improve the quality of ventilation systems in newly built houses [Dutch] Het actieplan bevat de afspraken die het ministerie van Infrastructuur en Milieu en het ministerie van Binnenlandse Zaken met de bouwpartijen hebben gemaakt om de kwaliteit van de ventilatievoorzieningen van nieuwbouwwoningen te verbeteren.

  11. The effect of a personalized ventilation system on perceived air quality and SBS symptoms

    DEFF Research Database (Denmark)

    Kaczmarczyk, Jan; Zeng, Q.; Melikov, Arsen Krikor

    2002-01-01

    Perceived air quality, SBS symptoms and performance were studied with 30 human subjects. Experiments were performed in an office set-up with six workplaces, each equipped with a Personalized Ventilation System (PVS). Each PVS allowed the amount of supply air and its direction to be controlled...... condition in regard to perceived air quality, perception of freshness and intensity of SBS symptoms was when PVS supplied outdoor air at 20 deg.C. Perceived air quality in this case was significantly better (p...

  12. Bedrock instability of underground storage systems in the Czech Republic, Central Europe

    Czech Academy of Sciences Publication Activity Database

    Nováková, Lucie; Brož, Milan; Záruba, J.; Sosna, K.; Najser, J.; Rukavičková, L.; Franěk, J.; Rudajev, V.

    2016-01-01

    Roč. 13, č. 2 (2016), s. 315-325 ISSN 1672-7975 R&D Projects: GA MPO(CZ) FR-TI1/367 Institutional support: RVO:67985891 ; RVO:67985530 Keywords : underground storage * instability * seismicity * Bohemian Massif Subject RIV: DD - Geochemistry Impact factor: 0.796, year: 2016

  13. Mapping For Literature Conceptual And Theoretical Framework And Methodology Case Of Hot Deep Mining Ventilation Engineering Evaluation And Design

    Directory of Open Access Journals (Sweden)

    Peter M. Lukonde

    2017-09-01

    Full Text Available The paper reports the layout of a mapping process for literature theoretical and conceptual framework and methodology for mining ventilation engineering evaluation design and methodology for a hot deep mine. The purpose of mine ventilation is to provide suitable environmental conditions in working places that promote comfort and efficiency as well as the safety and health of underground personnel. The objectives addressed in this paper include a evaluation of a current mine ventilation system for a hot deep-level mine taking into account the existing ventilation system infrastructure for building of a mine ventilation baseline parametric database for subsequent end of life mine ventilation design and b design of the extension end of mine life ventilation system taking into account increased production high geothermic gradient and subsequent increase in depth of mining. The methodology used in evaluating an existing underground mine ventilation system and designing the extension end of mine life ventilation system employed three stages i Literature mapping to identify authors titles and technical papers at global regional and nationaldistrict scales relevant to the research ii Conceptual and theoretical framework mapping to extract a kernel or core of concepts hypotheses and theories from the literature map to drive the formation of methods of implementation and iii Methodology and implementation mapping to direct and control the processes of data collection analysis and interpretation. A sample case study of a deep-level underground mine has been used in this paper to provide examples of data collection data analysis and interpretation key findings and results discussion and what is new conclusions and recommendations when the proposed mapping process is employed.

  14. Embedded Controller Design for Pig Stable Ventilation Systems

    DEFF Research Database (Denmark)

    Jessen, Jan Jacob

    present an early result for performing system identification for zone based climate dynamics, based on an idea of guaranteed internal flow directions. Paper 6 presents a verified stable distributed temperature controller for pig stables divided into zones. Paper 7 is an expanded journal version of paper 6......This thesis focuses on zone based climate control in pig stables and how to implement climate controllers in a new range of products. The presented controllers are based on simple models of climate dynamics and simple models of actuators. The implementation uses graphical point and click features...... from the Mathworks' range of products and automatic code generation. It is furthermore shown how to build new climate control systems based on cheap and readily available hardware and software. An early result for performing system identification for zone based climate dynamics is also presented...

  15. A knowledge- and model-based system for automated weaning from mechanical ventilation: technical description and first clinical application.

    Science.gov (United States)

    Schädler, Dirk; Mersmann, Stefan; Frerichs, Inéz; Elke, Gunnar; Semmel-Griebeler, Thomas; Noll, Oliver; Pulletz, Sven; Zick, Günther; David, Matthias; Heinrichs, Wolfgang; Scholz, Jens; Weiler, Norbert

    2014-10-01

    To describe the principles and the first clinical application of a novel prototype automated weaning system called Evita Weaning System (EWS). EWS allows an automated control of all ventilator settings in pressure controlled and pressure support mode with the aim of decreasing the respiratory load of mechanical ventilation. Respiratory load takes inspired fraction of oxygen, positive end-expiratory pressure, pressure amplitude and spontaneous breathing activity into account. Spontaneous breathing activity is assessed by the number of controlled breaths needed to maintain a predefined respiratory rate. EWS was implemented as a knowledge- and model-based system that autonomously and remotely controlled a mechanical ventilator (Evita 4, Dräger Medical, Lübeck, Germany). In a selected case study (n = 19 patients), ventilator settings chosen by the responsible physician were compared with the settings 10 min after the start of EWS and at the end of the study session. Neither unsafe ventilator settings nor failure of the system occurred. All patients were successfully transferred from controlled ventilation to assisted spontaneous breathing in a mean time of 37 ± 17 min (± SD). Early settings applied by the EWS did not significantly differ from the initial settings, except for the fraction of oxygen in inspired gas. During the later course, EWS significantly modified most of the ventilator settings and reduced the imposed respiratory load. A novel prototype automated weaning system was successfully developed. The first clinical application of EWS revealed that its operation was stable, safe ventilator settings were defined and the respiratory load of mechanical ventilation was decreased.

  16. How respiratory system mechanics may help in minimising ventilator-induced lung injury in ARDS patients.

    Science.gov (United States)

    Terragni, P P; Rosboch, G L; Lisi, A; Viale, A G; Ranieri, V M

    2003-08-01

    The main supportive therapy in acute respiratory distress syndrome patients is mechanical ventilation. As with any therapy, mechanical ventilation has side-effects, and may induce lung injury (ventilator-induced lung injury (VILI)/ventilator-associated lung injury). The mechanical factors responsible for VILI are thought to be related to tidal recruitment/derecruitment of previously collapsed alveoli and/or pulmonary overdistension. The volume/pressure (V/P) curve of the respiratory system in patients as well as in animal models of acute lung injury (ALI) has a characteristic sigmoid shape, with a lower inflection point (LIP) corresponding to the pressure/end-expiratory volume required to initiate recruitment of collapsed alveoli, and an upper inflection point (UIP) corresponding to the pressure/end inspiratory volume at which alveolar overdistension occurs. "Protective" ventilatory approaches have therefore set out to minimise mechanical injury by using the V/P curve to individualise positive end-expiratory pressure (PEEP) (PEEP above the LIP) and tidal volume (by setting end-inspiratory V/P below the UIP) since a large number of experimental studies correlate P/V curves to histological and biological manifestations of VILI and two randomised trials showed that protective ventilatory strategy individually tailored to the P/V curve minimised pulmonary and systemic inflammation and decreased mortality in patients with ALI. However, despite the fact that several studies have: 1) proposed new techniques to perform pressure/volume curves at the bedside, 2) confirmed that the lower inflection point and upper inflection point correspond to computed tomography scan evidence of atelectasis and overdistension, and 3) demonstrated the ability of the pressure/volume curve to estimate alveolar recruitment with positive end-expiratory pressure, no large studies have assessed whether such measurement can be performed in all intensive care units as a monitoring tool to orient

  17. Intelligent solar-powered automobile-ventilation system

    International Nuclear Information System (INIS)

    Huang, K. David; Tzeng, S.-C.; Ma Weiping; Wu Mingfung

    2005-01-01

    This study adopts airflow management technology to improve the local temperature distributions in an automobile to counteract the greenhouse effect. The automobile's temperature can be reduced to almost the outside temperature before the driver or passenger gets into the vehicle. When the engine is idling, the greenhouse-control system can be activated to remove the hot air from the car. An appropriate negative pressure is maintained to prevent stuffiness and save energy. The greenhouse-control system requires electrical power when the engine is idle, and a battery cannot supply sufficient power. An auxiliary solar-power supply can save energy and reduce the greenhouse effect of sunlight, while creating a comfortable traveling environment. It ensures that the engine is not overburdened and increases its service life, conserving energy, protecting the environment and improving comfort

  18. Manufacture, Installation and Operation of an In-situ Solute Migration System in KAERI Underground Research Tunnel (KURT)

    International Nuclear Information System (INIS)

    Lee, Jae Kwang; Baik, Min Hoon

    2009-07-01

    This report describes the design, installation, operation and maintenance of the in-situ solute migration system (IMS) which was installed in KAERI underground research tunnel (KURT) for the in-situ investigation of the solute migration. The IMS is consisted of the injection part, the extraction part, the measurement part, and the packer gas controlling system. The IMS was designed to measure the properties of the KURT groundwater in real time, which includes pH, redox potential, dissolved oxygen, electrical conductivity, and temperature. the remote control system was established to control the data processing unit through the internet

  19. Low-level multicounter β/γ systems with external guards in surface and shallow underground laboratories

    International Nuclear Information System (INIS)

    Theodorsson, P.

    1997-01-01

    When weak samples are measured it is important that they can be given ample counting time in order to obtain satisfactory accuracy and that the background count rate can be checked well. This calls for a high counting capacity, which multidetectors can bring us. I will discuss development possibilities of low-level β/γ multidetector systems with an external anticosmic shield that will in many cases be operated in underground laboratories. These simple and low-cost system can frequently help us in increasing the number of detectors. Three concepts are combined in these systems: (1) multidetectors, (2) an external anticosmic (or guard) detector arrangement and (3) overburden shielding. (orig.)

  20. Low-level multicounter {beta}/{gamma} systems with external guards in surface and shallow underground laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Theodorsson, P. [Iceland Univ. (Iceland). Science Inst.

    1997-03-01

    When weak samples are measured it is important that they can be given ample counting time in order to obtain satisfactory accuracy and that the background count rate can be checked well. This calls for a high counting capacity, which multidetectors can bring us. I will discuss development possibilities of low-level {beta}/{gamma} multidetector systems with an external anticosmic shield that will in many cases be operated in underground laboratories. These simple and low-cost system can frequently help us in increasing the number of detectors. Three concepts are combined in these systems: (1) multidetectors, (2) an external anticosmic (or guard) detector arrangement and (3) overburden shielding. (orig.)

  1. Development of Integrated Assessment System for Underground Power Cable Performance: A Case Study

    Science.gov (United States)

    Turan, Faiz Mohd; Johan, Kartina; Soliha Sahimi, Nur; Nor, Nik Hisyamudin Muhd

    2017-08-01

    The basic operation of any electrical machines that is catered to serve needs of civilization involves electrical power which is the main source to trigger the internal mechanism in the machines then transfer the power to other form of energy such as mechanical, light, sound and etc. The supplies of electrical does not happen just by providing the source itself, it has load carrying agent which in many cases, user would refer to it as cable. Specifically, it is the power cable which its ampacity depends significantly on the operation temperature and load stress on it. Apart from having to focus on providing improvement on improving efficiency on the source itself, power cable plays and important role because without it, current ranging from low to high could not be transmitted and hence a failure of the power system generally. Studies have conducted to discuss whether which factor contributes relatively more to the causes of power cable failure or breakdown. Such factors can be narrowed down to the three major causes which are over temperature, over voltage and stress caused by over current. Over current is one of the factor which is depends on the usage of the power system itself. The higher the usage of the power system, higher the chances of over current to take place. This will then produce load stress on the cable which eventually destroy the insulator of the cable and slowly reach the core of the cable. It is believed that an assessment method should be implemented in order to predict the performance and failure rate of the power cable and use this prediction as reference rather than just letting power failure to happen anytime unpredictable which cause huge inconvenience to users and industries. Not only do a method should be implemented, it should be as easy to be used and understood by large range of users and integrated by a graphical user interface to be used. Therefore, this research will further narrow down on the approaches to do so and the location

  2. Rokibaar Underground = Rock bar Underground

    Index Scriptorium Estoniae

    2008-01-01

    Rokibaari Underground (Küütri 7, Tartu) sisekujundus, mis pälvis Eesti Sisearhitektide Liidu 2007. a. eripreemia. Sisearhitekt: Margus Mänd (Tammat OÜ). Margus Männist, tema tähtsamad tööd. Plaan, 5 värv. vaadet, foto M. Männist

  3. Correlation between germ and particle measurements for the qualification of ventilation systems in the OR

    Directory of Open Access Journals (Sweden)

    Bulitta Clemens

    2017-09-01

    Full Text Available Healthcare associated infections in surgical procedures have long been the focus of scientific research. In Germany, more than 225,000 patients suffer from such infections each year [1]. However, the reduction of the microbiological contamination is not only limited by cleaning and disinfecting measures. The choice of the ventilation system in the operating room or the type of the clothing of the personnel during the operation is also an important factor contributing to patient safety and infection control. Currently there are different approaches for assessing the hygienic situation in an operating room. In Germany, the air quality and cleanliness is evaluated by the DIN 1946-4: 2008-12 [2] and is based on the measurement of particles in the operating theatre. Other countries i.eSweden. focus on the biological contamination and use microbiological methods for the assessment and surveillance of the operating room ventilation (SIS-TS 39: 2015 [3].

  4. Numerical analysis of natural ventilation system in a studio apartment in Bangladesh

    Science.gov (United States)

    Kabir, K. M. Ariful; Hasan, Md. Rakibul; Khan, Md. Abdul Hakim

    2017-07-01

    The study of temperature and air flow for natural ventilation system has been investigated numerically. A finite element model for studio apartment was developed with the aim of achieving detail energy allocation in the real buildings during the transient process in the walls and internal air. A tool of computational fluid dynamics (CFD) is employed to assist the process. In the tropical regions most of the energy is consumed by the heating, cooling and ventilation appliances. Therefore, the optimize ventilation system will be a suitable and valid option for the saving of energy from the household sector to increase cooling performance and ensuring thermal comfort as well. A mathematical exploration is carried out on full scale dwelling and small scale model and indication is given on the relevance of such a comparison. Calculations are carried out with household heat sources for calm and windy period, but without any human. As expected, for windy periods, the wind is the main driving force behind the internal air flow. However, in calm periods for unsteady flow the internal airflow looks like more complexes through observation.

  5. Development of a research-oriented system for collecting mechanical ventilator waveform data.

    Science.gov (United States)

    Rehm, Gregory B; Kuhn, Brooks T; Delplanque, Jean-Pierre; Guo, Edward C; Lieng, Monica K; Nguyen, Jimmy; Anderson, Nicholas R; Adams, Jason Y

    2017-10-28

    Lack of access to high-frequency, high-volume patient-derived data, such as mechanical ventilator waveform data, has limited the secondary use of these data for research, quality improvement, and decision support. Existing methods for collecting these data are obtrusive, require high levels of technical expertise, and are often cost-prohibitive, limiting their use and scalability for research applications. We describe here the development of an unobtrusive, open-source, scalable, and user-friendly architecture for collecting, transmitting, and storing mechanical ventilator waveform data that is generalizable to other patient care devices. The system implements a software framework that automates and enforces end-to-end data collection and transmission. A web-based data management application facilitates nontechnical end users' abilities to manage data acquisition devices, mitigates data loss and misattribution, and automates data storage. Using this integrated system, we have been able to collect ventilator waveform data from >450 patients as part of an ongoing clinical study. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. High-efficiency ventilation and heating systems by means of solar air collectors for industry building refurbishment

    OpenAIRE

    Benoit Sicre; Patrick Baumann

    2015-01-01

    For the purpose of energy conservation, modern buildings are becoming more and more air-tight and generally rely on a mechanical ventilation system. According to the literature, solar air heating systems can contribute in a cost-effective way to the heating and ventilation of utility buildings. Especially cost-efficient, unglazed, façade-integrated solar air collectors seem to be an attractive new market for façade renovation. To demonstrate the technical feasibility of generating heating ene...

  7. Design Principles for Natural and Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per

    For many years mechanical and natural ventilation systems have developed separately. Naturally, the next step in this development is the development of ventilation concepts that utilize and combine the best features from each system to create a new type of ventilation system- Hybrid Ventilation....... The hybrid ventilation concepts, design challenges and principles are discussed and illustrated by four building examples....

  8. Numerical analysis of diffuse ceiling ventilation and its integration with a radiant ceiling system

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Chen, Qingyan

    2017-01-01

    A novel system combining diffuse ceiling ventilation and radiant ceiling was proposed recently, with the aim of providing energy efficient and comfort environment to office buildings. Designing of such a system is challenging because of complex interactions between the two subsystems and a large...... number of design parameters encountered in practice. This study aimed to develop a numerical model that can reliably predict the airflow and thermal performance of the integrated system during the design stage. The model was validated by experiments under different operating conditions. The validated...

  9. [A design of simple ventilator control system based on LabVIEW].

    Science.gov (United States)

    Pei, Baoqing; Xu, Shengwei; Li, Hui; Li, Deyu; Pei, Yidong; He, Haixing

    2011-01-01

    This paper designed a ventilator control system to control proportional valves and motors. It used LabVIEW to control the object mentioned above and design ,validate, evaluate arithmetic, and establish hardware in loop platform. There are two system' s hierarchies. The high layer was used to run non-real time program and the low layer was used to run real time program. The two layers communicated through TCP/IP net. The program can be divided into several modules, which can be expanded and maintained easily. And the harvest in the prototype designing can be seamlessly used to embedded products. From all above, this system was useful in employing OEM products.

  10. Underground Politics

    DEFF Research Database (Denmark)

    Galis, Vasilis; Summerton, Jane

    of various kinds, as well as for identifying and displacing undesired individuals/groups/bodies. A case in point is a recently-established police project (REVA) in Sweden for strengthening the so-called internal border control. Specifically, several underground stations in Stockholm now have checkpoints......Public spaces are often contested sites involving the political use of sociomaterial arrangements to check, control and filter the flow of people (see Virilio 1977, 1996). Such arrangements can include configurations of state-of-the-art policing technologies for delineating and demarcating borders...... status updates on identity checks at the metro stations in Stockholm and reports on locations and time of ticket controls for warning travelers. Thus the attempts by authorities to exert control over the (spatial) arena of the underground is circumvented by the effective developing of an alternative...

  11. Underground passenger comfort : rethinking the current thermal and lighting standards

    Energy Technology Data Exchange (ETDEWEB)

    Raines, K.M. [Architectural Association Graduate School, London (United Kingdom). Environment and Energy Studies Programme

    2009-07-01

    This paper reported on a study that examined methods to improve passenger comfort in London's mass public underground transport system. In Central London, passenger surveys and thermal measuring have revealed that underground train stations are thermally uncomfortable, especially in older and deeper tunnels. Problems include excess heat accumulation, insufficient ventilation, occupancy overcrowding, and disconnection from the outside environment. New air-conditioning coupled with increasing station occupancies could lead to an increase in the excessive internal heat gains and the degradation of the soil capacity around the tunnels to absorb heat. This study examined the existing energy-intensive and unsatisfactory methods of cooling and lighting in London's underground stations and explored passive and low-energy strategies to improve human comfort. Environmental modelling software was used to analyze several strategies to improve passenger comfort. Simulations revealed that dynamic design solutions can introduce subterranean sunlight at the platform level and modulate the thermal interaction between the indoor and outdoor environments to achieve a comfortable equilibrium. Thermal analysis showed that increasing the ventilation would help to cool the thermal mass of the station construction and surrounding soil, help to dissipate internal heat gains, improve passenger comfort, and may replace the need for mechanical systems. The study found that by implementing methods that suit the seasonal conditions, the indoor temperatures can adapt to provide thermal neutrality to its passengers. Hybrid systems for ventilation, cooling, and lighting may provide year-round comfort. Coupling and decoupling of the building with the outdoor environment can increase the comfort level of indoor temperatures throughout the year. It was concluded that the ground surrounding the tunnel would be able to absorb more heat if the thermal conductivity of the tunnel surface were

  12. J-shape ventilation system for controlling high gas emission at fully mechanized sub-level caving face

    Energy Technology Data Exchange (ETDEWEB)

    Wang, K.; Yu, Q.; Miao, X. (and others) [CUMT, Xuzhou (China). School of Mineral and Safety Engineering

    2004-07-01

    Considering the practical condition of No. 5201 fully mechanized sub-level caving face in Wangzhuang Coal Mine of Lu'an Mining Group, and based on the successfully retaining of small section entry along gob side, a method of J-shape ventilation system and its regulating technology were put forward for controlling high gas emission at fully mechanized sub-level caving face. Essentially, the J-shape ventilation system has one intake and two returns for controlling high gas emission according to different gas sources using ventilation measure. Through practical application it is proved that local gas accumulation at coal face and its upper corner can be eliminated by adopting J-shape ventilation system, thus high-production and high-efficiency of fully mechanized sub-level caving face can be also realized. 6 refs., 6 figs., 1 tab.

  13. Evaluation of comfort level in desks equipped with two personalized ventilation systems in slightly warm environments

    Energy Technology Data Exchange (ETDEWEB)

    Conceicao, Eusebio Z.E. [Faculdade de Ciencias e Tecnologia - Universidade do Algarve, Campus de Gambelas, 8005-139 Faro (Portugal); Lucio, Manuela J.R. [Agrupamento Vertical Professor Paula Nogueira, R. Comunidade Lusiada, 8700-000 Olhao (Portugal); Rosa, Silvia P.; Custodio, Ana L.V.; Andrade, Renata L.; Meira, Maria J.P.A. [Faculdade de Ciencias do Mar e do Ambiente - Universidade do Algarve, Campus de Gambelas, 8005-139 Faro (Portugal)

    2010-03-15

    In this work the comfort level, namely the thermal comfort, local thermal discomfort and air quality levels, in a classroom with desks equipped with two personalized ventilation systems, in slightly warm environments, is evaluated. A manikin, a ventilated classroom desk, two indoor climate analyzers, a multi-nodal human thermal comfort numerical model and a computational fluid dynamic numerical model, are used. The classroom desk, with double occupation capacity, is used by a student, located in the right side seat. Each personalized ventilation system is equipped with one air terminal device located above the desk writing area, in front to the trunk area, and an other located below the desk writing area, in front to the legs area. The thermal comfort level is evaluated by the developed multi-nodal human thermal comfort numerical model, using a PMV value, the local thermal discomfort level, namely the draught risk and the air velocity fluctuation equivalent frequencies, is evaluated by empirical models, while the air quality level and the detailed airflow around the manikin are evaluated by the computational fluid dynamic numerical model. In the experimental tests the mean air velocity and the turbulence intensity in the upper air terminal device are 3.5 m/s and 9.7%, while in the lower air terminal device are 2.6 m/s and 15.2%. The mean air temperature in the air terminal devices is around 28 C, while the mean radiant temperature in the occupation area, the mean air temperature far from the occupation area and the internal mean air relative humidity were, respectively, 28 C, 28 C and 50%. The air velocity and temperature around the occupant are measured around 15 human body sections. The actual personalized ventilation system, which promotes an ascendant airflow around the occupant with highest air renovation rate in the respiration area, promotes acceptable thermal comfort conditions and air quality in the respiration area in accord to the present standards. The

  14. Physicochemical Characterization of Nanoparticles from Indoor Ventilation Systems and Their Potential Health Impacts

    Science.gov (United States)

    Dalton, G.; Revkin, A. C.; Gruenspecht, H.; Ramanathan, V.; Brown, M. A.; Nagel, D. C.; Revkin, A. C.; Umo, N. S.; Oseghe, E. O.

    2016-12-01

    Indoor air pollution remains a major concern to humans considering that we spend about 90% of our daily lives indoors [1,2]. Air pollutants, which ranges from gases to aerosol particles, vary considerably from our homes, public/work places and confined environments such as cars. They can impact on our health depending on the nature and concentration of the pollutants as well as the duration of exposure [3,4]. Particulate matter (PM), which is one of the major air pollutant markers, is present indoors and can be circulated for days to months within a confined space by the ventilation systems. In this study, both physical and chemical compositional evaluation of PM2.5 - 10 was carried out and the recirculation model of these particulates is presented based on the study of some ventilation systems such as air conditioners, cooling vents, and fans. For the first time, it is shown that the compositional variability of PM does not just depend on the source or the ongoing activities in the confined space but also on the recirculation time. Mineral dust particles were found to be dominant, some mixed with organics and soot or BC particles; heavy metals such as lead (Pb), cadmium (Cd), nickel (Ni), iron (Fe) and others were also analysed from the collected PM. Ventilation systems trap these particulates and do recirculate them over time and this can increase their toxicities and influences their composition. From this study, it can be suggested that regular cleaning of ventilation systems and flushing closed spaces with fresh air may become the most effective ways of controlling the concentration of PM in closed spaces with ventilation units such as indoors and cars. [1] H. K. Lai, et al., Atmospheric Environment 38 (37)(2004). [2] N.E. Klepeis, et al., J. of Exposure Analysis and Environmental Epidemiology 11(2001). [3] N. Bruce, et al., Bul. of the World Health Organization, 78 (9)(2000). [4] K.A. Miller, et al, The New England Journal of Medicine 356 (2007).

  15. Inspiratory capacity at inflation hold in ventilated newborns: a surrogate measure for static compliance of the respiratory system.

    Science.gov (United States)

    Hentschel, Roland; Semar, Nicole; Guttmann, Josef

    2012-09-01

    To study appropriateness of respiratory system compliance calculation using an inflation hold and compare it with ventilator readouts of pressure and tidal volume as well as with measurement of compliance of the respiratory system with the single-breath-single-occlusion technique gained with a standard lung function measurement. Prospective clinical trial. Level III neonatal unit of a university hospital. Sixty-seven newborns, born prematurely or at term, ventilated for a variety of pathologic conditions. A standardized sigh maneuver with a predefined peak inspiratory pressure of 30 cm H2O, termed inspiratory capacity at inflation hold, was applied. Using tidal volume, exhaled from inspiratory pause down to ambient pressure, as displayed by the ventilator, and predefined peak inspiratory pressure, compliance at inspiratory capacity at inflation hold conditions could be calculated as well as ratio of tidal volume and ventilator pressure using tidal volume and differential pressure at baseline ventilator settings: peak inspiratory pressure minus positive end-expiratory pressure. For the whole cohort, the equation for the regression between tidal volume at inspiratory capacity at inflation hold and compliance of the respiratory system was: compliance of the respiratory system = 0.052 * tidal volume at inspiratory capacity at inflation hold - 0.113, and compliance at inspiratory capacity at inflation hold conditions was closely related to the standard lung function measurement method of compliance of the respiratory system (R = 0.958). In contrast, ratio of tidal volume and ventilator pressure per kilogram calculated from the ventilator readouts and displayed against compliance of the respiratory system per kilogram yielded a broad scatter throughout the whole range of compliance; both were only weakly correlated (R = 0.309) and also the regression line was significantly different from the line of identity (p respiratory system. After a standard sigh maneuver

  16. A static pressure reset control system with a new type of flow damper for use in low pressure ventilation systems

    DEFF Research Database (Denmark)

    Terkildsen, Søren; Svendsen, Svend

    2012-01-01

    The control strategy for mechanical ventilation systems has significant impact on the performance of the system, in terms of energy consumption and correct air distribution. This paper presents a static pressure reset control system employing a new type of flow damper with lower pressure loss...... for use in low pressure ventilation systems. The flow damper has a droplet shape that minimizes turbulence generation and the resulting pressure loss. The performance of the damper was examined by making measurements of pressure loss and airflow. These were used to determine the required pressure loss...... for operation and the airflow accuracy. Results were compared to similar tests carried out with conventional flat plate dampers. A static pressure reset control algorithm was programmed and analyzed on a test system consisting of three dampers, representing three office rooms. The comparison of the dampers...

  17. Suicide patterns on the London Underground railway system, 2000-2010.

    Science.gov (United States)

    Martin, Susanna; Rawala, Muffazal

    2017-10-01

    Aims and Method Suicidal acts on underground railway networks are an area of public health concern. Our aim was to review recent epidemiological patterns of suicidal acts on the London Underground to inform future preventive interventions. Data from 2000 to 2010 were obtained from the British Transport Police via a Freedom of Information request. Results The mean annual rate of suicidal acts from 2000 to 2010 was 5.8 per 100 million passenger journey stages. Of those who died by suicide, 77.3% were of White Northern European ethnicity. A fifth had a history of mental illness. Clinical implications The widening gap between the number of recorded suicide attempts and completed suicides is encouraging. Further research is required regarding the role of drug and alcohol use, psychiatric history and area of residence. Installation of platform screen doors should be considered in future railway network expansion.

  18. Suicide patterns on the London Underground railway system, 2000–2010

    Science.gov (United States)

    Martin, Susanna; Rawala, Muffazal

    2017-01-01

    Aims and Method Suicidal acts on underground railway networks are an area of public health concern. Our aim was to review recent epidemiological patterns of suicidal acts on the London Underground to inform future preventive interventions. Data from 2000 to 2010 were obtained from the British Transport Police via a Freedom of Information request. Results The mean annual rate of suicidal acts from 2000 to 2010 was 5.8 per 100 million passenger journey stages. Of those who died by suicide, 77.3% were of White Northern European ethnicity. A fifth had a history of mental illness. Clinical implications The widening gap between the number of recorded suicide attempts and completed suicides is encouraging. Further research is required regarding the role of drug and alcohol use, psychiatric history and area of residence. Installation of platform screen doors should be considered in future railway network expansion. PMID:29018553

  19. Parametric study on the advantages of weather-predicted control algorithm of free cooling ventilation system

    International Nuclear Information System (INIS)

    Medved, Sašo; Babnik, Miha; Vidrih, Boris; Arkar, Ciril

    2014-01-01

    Predicted climate changes and the increased intensity of urban heat islands, as well as population aging, will increase the energy demand for the cooling of buildings in the future. However, the energy demand for cooling can be efficiently reduced by low-exergy free-cooling systems, which use natural processes, like evaporative cooling or the environmental cold of ambient air during night-time ventilation for the cooling of buildings. Unlike mechanical cooling systems, the energy for the operation of free-cooling system is needed only for the transport of the cold from the environment into the building. Because the natural cold potential is time dependent, the efficiency of free-cooling systems could be improved by introducing a weather forecast into the algorithm for the controlling. In the article, a numerical algorithm for the optimization of the operation of free-cooling systems with night-time ventilation is presented and validated on a test cell with different thermal storage capacities and during different ambient conditions. As a case study, the advantage of weather-predicted controlling is presented for a summer week for typical office room. The results show the necessity of the weather-predicted controlling of free-cooling ventilation systems for achieving the highest overall energy efficiency of such systems in comparison to mechanical cooling, better indoor comfort conditions and a decrease in the primary energy needed for cooling of the buildings. - Highlights: • Energy demand for cooling will increase due to climate changes and urban heat island • Free cooling could significantly reduce energy demand for cooling of the buildings. • Free cooling is more effective if weather prediction is included in operation control. • Weather predicted free cooling operation algorithm was validated on test cell. • Advantages of free-cooling on mechanical cooling is shown with different indicators

  20. Numerical Study on Different Series Modes of Jet Fan in a Longitudinal Tunnel Ventilation System

    Directory of Open Access Journals (Sweden)

    Guihong Pei

    2014-01-01

    Full Text Available Efficient ventilation systems will contribute to maintaining air quality in the tunnel. In order to improve ventilation performance in normal traffic condition, the 3D tunnel models were established according to the original design for the tunnel located in central plains of China. Based on the commercial CFD software Fluent 6.3 and k-ε turbulence model, numerical simulations were carried out to study the patterns of jet flow and the optimization of fan combinations. It is found that the axial velocity profile obtained from numerical simulation agrees quite well with turbulent free jet theory although there is a little difference on the magnitude. The comparison of four combination modes under the condition of operating four fans indicates that the ventilation effectiveness is affected mainly by both the interval of adjacent groups of fans and the combination modes of operational fans. According to the simulation results, a novel combination mode which consists of a group double paralleled fans and two groups single fan is designed. The novel combination mode is regarded as the optimum combination mode with respect to maximizing air velocity in the tunnel. Compared to the traditional combination modes, it will increase the air velocity by 5.7%.

  1. Dynamic Underground Stripping Project

    International Nuclear Information System (INIS)

    Aines, R.; Newmark, R.; McConachie, W.; Udell, K.; Rice, D.; Ramirez, A.; Siegel, W.; Buettner, M.; Daily, W.; Krauter, P.; Folsom, E.; Boegel, A.J.; Bishop, D.; Udell, K.

    1992-01-01

    LLNL is collaborating with the UC Berkeley College of Engineering to develop and demonstrate a system of thermal remediation and underground imaging techniques for use in rapid cleanup of localized underground spills. Called ''Dynamic Stripping'' to reflect the rapid and controllable nature of the process, it will combine steam injection, direct electrical heating, and tomographic geophysical imaging in a cleanup of the LLNL gasoline spill. In the first 8 months of the project, a Clean Site engineering test was conducted to prove the field application of the techniques before moving the contaminated site in FY 92

  2. Contribution to the study of hybrid ventilation system effectiveness in office and educational buildings; Contribution a l'etude de l'efficacite des systemes de ventilation hybride dans les batiments du secteur tertiaire

    Energy Technology Data Exchange (ETDEWEB)

    Cron, F.

    2004-06-15

    This study is part of the International Energy Agency Annex 35, 'Hybrid Ventilation in New and Retro-fitted Office Buildings', also called the HybVent Project. It presents the numerical analyses of a number of hybrid ventilation systems and their potential for several buildings in relation to local climate characteristics. The first part of this work reviews the state-of-the-art of existing ventilation systems and details the principles, expectations and features of hybrid ventilation systems. This first section also examines some examples of hybrid systems extracted from the collection of Annex 35 case studies. A comprehensive bibliography of numerical tools available for this type of analysis is given in the second section. The numerical models for building simulation and the object-oriented environment used to develop our simulation tool are presented in this section as well. Two single-zone studies undertaken in this project are reported in the third section. The first study concerns an experimental cell simulation. Numerical results are compared to experimental data to validate the use of the simulation tool developed. The second single-zone study predicts the potential of a specific hybrid ventilation system in a typical classroom, given climatic conditions. Finally, the last section presents a more complete study - a multi-zone study of the Tonga school, an Annex 35 case study located in Sweden. Three rooms were modelled initially to compare numerical results to experimental data and then to analyse the performance of the existing hybrid ventilation system and two other systems. This final study was completed for three European cities with very different climates. The overall analysis of the potential of the hybrid ventilation systems considered and the perspective for future work are outlined in the conclusion. (author)

  3. Corrective Action Plan for Corrective Action Unit 262: Area 25 Septic Systems and Underground Discharge Point, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    K. B. Campbell email = campbek@nv.doe.gov

    2002-01-01

    This Corrective Action Plan (CAP) provides selected corrective action alternatives and proposes the closure methodology for Corrective Action Unit (CAU) 262, Area 25 Septic Systems and Underground Discharge Point. CAU 262 is identified in the Federal Facility Agreement and Consent Order (FFACO) of 1996. Remediation of CAU 262 is required under the FFACO. CAU 262 is located in Area 25 of the Nevada Test Site (NTS), approximately 100 kilometers (km) (62 miles [mi]) northwest of Las Vegas, Nevada. The nine Corrective Action Sites (CASs) within CAU 262 are located in the Nuclear Rocket Development Station complex. Individual CASs are located in the vicinity of the Reactor Maintenance, Assembly, and Disassembly (R-MAD); Engine Maintenance, Assembly, and Disassembly (E-MAD); and Test Cell C compounds. CAU 262 includes the following CASs as provided in the FFACO (1996); CAS 25-02-06, Underground Storage Tank; CAS 25-04-06, Septic Systems A and B; CAS 25-04-07, Septic System; CAS 25-05-03, Leachfield; CAS 25-05-05, Leachfield; CAS 25-05-06, Leachfield; CAS 25-05-08, Radioactive Leachfield; CAS 25-05-12, Leachfield; and CAS 25-51-01, Dry Well. Figures 2, 3, and 4 show the locations of the R-MAD, the E-MAD, and the Test Cell C CASs, respectively. The facilities within CAU 262 supported nuclear rocket reactor engine testing. Activities associated with the program were performed between 1958 and 1973. However, several other projects used the facilities after 1973. A significant quantity of radioactive and sanitary waste was produced during routine operations. Most of the radioactive waste was managed by disposal in the posted leachfields. Sanitary wastes were disposed in sanitary leachfields. Septic tanks, present at sanitary leachfields (i.e., CAS 25-02-06,2504-06 [Septic Systems A and B], 25-04-07, 25-05-05,25-05-12) allowed solids to settle out of suspension prior to entering the leachfield. Posted leachfields do not contain septic tanks. All CASs located in CAU 262 are

  4. 30 CFR 75.313 - Main mine fan stoppage with persons underground.

    Science.gov (United States)

    2010-07-01

    ... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.313 Main... and areas where mechanized mining equipment is being installed or removed. (b) If ventilation is...) Underground power circuits shall not be energized and nonpermissible mechanized equipment shall not be started...

  5. Evaluation of a Mapleson D CPAP system for weaning of mechanical ventilation in pediatric patients.

    Science.gov (United States)

    Palomero-Rodríguez, Miguel Angel; de Arteaga, Héctor Chozas; Báez, Yolanda Laporta; de Vicente Sánchez, Jesús; Carretero, Pascual Sanabria; Conde, Pilar Sánchez; Pérez Ferrer, Antonio

    2016-01-01

    Over the last years, we have used a flow-inflating bag circuit with a nasotracheal or nasopharyngeal tube as an interface to deliver effective CPAP support in infants ("Mapleson D CPAP system"). The primary goal of this study was to assess the usefulness of the "Mapleson D CPAP system" for weaning of mechanical ventilation (MV) in infants who received MV over 24 h. All infants who received MV for more than 24 h in the last year were enrolled in the study. Demographic data included age, gender, weight, and admission diagnosis. Heart rate, respiratory rate, blood pressure, and oxygen saturation were measured during MV, 2 h after the nasotracheal Mapleson D CPAP system and 2 h after extubation. Patients were classified into two groups: patients MV more than 48 h, and patients with MV fewer than 48 h. P Mapleson D CPAP system and 2 h after extubation and spontaneous ventilation with the nasopharyngeal Mapleson D CPAP system or with nasal prongs. The overall extubation failure rate was 26% (n = 13). Weight and age were significantly associated with extubation failure (P Mapleson D CPAP system, in our opinion, is a useful and safe alternative to more complex and expensive noninvasive CPAP and BiPAP weaning from MV in infants.

  6. Assessment of the underground construction details of a road pavement using GPR antenna systems with different frequencies

    Science.gov (United States)

    Alani, Amir M.; Tosti, Fabio; Bianchini Ciampoli, Luca; Benedetto, Francesco; Benedetto, Andrea

    2017-04-01

    The assessment of the underground construction details of a road infrastructure is a problem of great concern in highway engineering. The case becomes complicated especially when damages reoccur after carrying out remedial surface maintenance and repair works over the life cycle of the infrastructure. The challenge will be exacerbated at the presence of underground watercourses, such that the geotechnical stability of the entire road structure could be threatened. In this respect, ground-penetrating radar (GPR) has been recognised and accepted as one of the most effective non-destructive testing (NDT) techniques that could be employed in identifying the cause/s of such problems. The recent advancements and developments made in the field of GPR hardware as well as the current level of understanding of the applications and processing techniques of the GPR data have immensely added to the reliability in the utilisation of this tool in variety of subsurface investigation projects. In view of this, the work presented in here focuses on the assessment of the underground construction details of a road pavement using different frequency GPR antenna systems. In addition to this, the possible presence and location of an underground watercourse was investigated in this work. The existence of the latter problem was perceived due to reoccurrence of longitudinal and traversal road surface cracking as well as subsidence at a particular location of the road. Reoccurrence of this damage was interpreted and related to the possible existence of an underground watercourse. The original design and the construction of the road were as such to prevent this movement. Therefore it seemed necessary to perform a GPR survey to investigate and confirm the underground construction details of the road. To this purpose, the identified area was surveyed using high to low frequency antennas with 2000 MHz, 900 MHz, 600 MHz and 200 MHz central frequencies of investigation. Scans were performed at 1m

  7. Application of ergonomics principles in underground mines through the Occupational Safety and Health Management System--OSHMS OHSAS 18.001:2007.

    Science.gov (United States)

    de Arruda, Agnaldo Fernando Vieira; Gontijo, Leila Maral

    2012-01-01

    The underground mining activity is regarded as one of the activities that cause most accidents, deaths and illnesses in the world, highlighting the coal mines. This study examined how ergonomics principles can help improve this environment, reduce the number of accidents and occupational diseases, train and empower workers and leaders and humanize the activities of the duty cycle of an underground mine. For this, it was developed a conceptual model of safety managing and health at work for the underground mining through the incorporation of ergonomics principles in the Occupational Safety and Health Management System and OHSAS 18001 (2007). The elaboration of the model was based on analysis of the environments and stages of work in underground mines and the PDCA cycle to ensure continuous improvement.

  8. Reflection Phenomena in Underground Pumped Storage Reservoirs

    Directory of Open Access Journals (Sweden)

    Elena Pummer

    2018-04-01

    Full Text Available Energy storage through hydropower leads to free surface water waves in the connected reservoirs. The reason for this is the movement of water between reservoirs at different elevations, which is necessary for electrical energy storage. Currently, the expansion of renewable energies requires the development of fast and flexible energy storage systems, of which classical pumped storage plants are the only technically proven and cost-effective technology and are the most used. Instead of classical pumped storage plants, where reservoirs are located on the surface, underground pumped storage plants with subsurface reservoirs could be an alternative. They are independent of topography and have a low surface area requirement. This can be a great advantage for energy storage expansion in case of environmental issues, residents’ concerns and an unusable terrain surface. However, the reservoirs of underground pumped storage plants differ in design from classical ones for stability and space reasons. The hydraulic design is essential to ensure their satisfactory hydraulic performance. The paper presents a hybrid model study, which is defined here as a combination of physical and numerical modelling to use the advantages and to compensate for the disadvantages of the respective methods. It shows the analysis of waves in ventilated underground reservoir systems with a great length to height ratio, considering new operational aspects from energy supply systems with a great percentage of renewable energies. The multifaceted and narrow design of the reservoirs leads to complex free surface flows; for example, undular and breaking bores arise. The results show excessive wave heights through wave reflections, caused by the impermeable reservoir boundaries. Hence, their knowledge is essential for a successful operational and constructive design of the reservoirs.

  9. Study on the reliability of the underground conveyor belt system installed at Vulcan Mine, the Jiu Valley Basin in Romania

    Directory of Open Access Journals (Sweden)

    Tomuș Ovidiu-Bogdan

    2017-01-01

    Full Text Available The paper deals with a comprehensive reliability analysis of the conveyor belts belonging to an underground coal mine in the Jiu Valley, Romania. As resulted from the mine management reports, the transportation system is responsible for many downtimes and is a real bottleneck in the constant and adequate production, and the suspicion is the weak state of belt conveyers, which are the spinal column of the extraction process. For this reason, a comprehensive reliability analysis has been decided, in order to deliver a maintenance-upgrading plan.

  10. Evaluation of local exhaust ventilation system performance for control of Fe2O3 dust at an iron making unit

    Directory of Open Access Journals (Sweden)

    Mahdi Jamshidi Rastani

    2016-06-01

    Full Text Available Introduction: Adherence to the design values and ventilation standards (VS after installing and also maintaining continuous work of ventilation system with maximum performance throughout its life are amongst the reasons of ventilation systems monitoring. Therefore, the aim of this study was to evaluate performance of local exhaust ventilation system for control of dust by measuring the operating parameters and also to compare it with ventilation standards (VS and design values. Material and Method: The present research is a descriptive and cross-sectional study, conducted in three sections of measuring, monitoring and evaluating the operating parameters on hoods, channels and fan of ventilation system based on the current status of the system, documentation (design, and recommended standards (VS. Static pressure, velocity pressure, surface area, and flow rate were measured based on the recommendations of various sources and ACGIH industrial ventilation manual, and the data were compared with the design and recommended values, using the SPSS software version 16.   Result: The results of paired sample t-test between flow rate and velocities of design and current status, showed significant differences in various parts. Accordingly, the results revealed a reduction of more than 50% in the design duct velocity compared to the current duct velocity, while design duct velocity is 1.3 more than the standard duct velocity of current status, and current duct velocity is about 65% of standard duct velocity. Conclusion: The reduction and nonconformity of the results of measurements of operating parameters (after a minimum of two decades with design and standard values are corroborant and sufficient reason for obstructions, abrasions, leaks, imbalance of system ducts and their inefficiency in some branches. Since there is no base line measurements for system (supposing that the system worked with maximum amounts of setup time, one of the reasons for these

  11. A risk-based decision support framework for selection of appropriate safety measure system for underground coal mines.

    Science.gov (United States)

    Samantra, Chitrasen; Datta, Saurav; Mahapatra, Siba Sankar

    2017-03-01

    In the context of underground coal mining industry, the increased economic issues regarding implementation of additional safety measure systems, along with growing public awareness to ensure high level of workers safety, have put great pressure on the managers towards finding the best solution to ensure safe as well as economically viable alternative selection. Risk-based decision support system plays an important role in finding such solutions amongst candidate alternatives with respect to multiple decision criteria. Therefore, in this paper, a unified risk-based decision-making methodology has been proposed for selecting an appropriate safety measure system in relation to an underground coal mining industry with respect to multiple risk criteria such as financial risk, operating risk, and maintenance risk. The proposed methodology uses interval-valued fuzzy set theory for modelling vagueness and subjectivity in the estimates of fuzzy risk ratings for making appropriate decision. The methodology is based on the aggregative fuzzy risk analysis and multi-criteria decision making. The selection decisions are made within the context of understanding the total integrated risk that is likely to incur while adapting the particular safety system alternative. Effectiveness of the proposed methodology has been validated through a real-time case study. The result in the context of final priority ranking is seemed fairly consistent.

  12. Evaluation of the Ventilation and Air Cleaning System Design Concepts for Safety Requirements during Fire Conditions in Nuclear Applications

    International Nuclear Information System (INIS)

    Rashad, S.; El-Fawal, M.; Kandil, M.

    2013-01-01

    The ventilation and air cleaning system in the nuclear or radiological installations is one of the essential nuclear safety concerns. It is responsible for confining the radioactive materials involved behind suitable barriers during normal and abnormal conditions. It must be designed to prevent the release of harmful products (radioactive gases, or airborne radioactive materials) from the system or facility, impacting the public or workers, and doing environmental damage. There are two important safety functions common to all ventilation and air cleaning system in nuclear facilities. They are: a) the requirements to maintain the pressure of the ventilated volume below that of surrounding, relatively non-active areas, in order to inhibit the spread of contamination during normal and abnormal conditions, and b) the need to treat the ventilated gas so as to minimize the release of any radioactive or toxic materials. Keeping the two important safety functions is achieved by applying the fire protection for the ventilation system to achieve safety and adequate protection in nuclear applications facilities during fire and accidental criticality conditions.The main purpose of this research is to assist ventilation engineers and experts in nuclear installations for safe operation and maintaining ventilation and air cleaning system during fire accident in nuclear facilities. The research focuses on fire prevention and protection of the ventilation systems in nuclear facilities. High-Efficiency particulate air (HEPA) filters are extremely susceptible to damage when exposed to the effects of fire, smoke, and water; it is the intent of this research to provide the designer with the experience gained over the years from hard lessons learned in protecting HEPA filters from fire. It describes briefly and evaluates the design safety features, constituents and working conditions of ventilation and air cleaning system in nuclear and radioactive industry.This paper provides and

  13. Emergency automatic commutation of the ventilation system of the RP-10 nuclear reactor

    International Nuclear Information System (INIS)

    Castillo, Walter; Corimanya, Mario; Ovalle, Edgar; Anaya, Olgger; Veramendi, Emilio

    2013-01-01

    The present paper summarizes the achievements in the design and implementation of a system for monitoring and automatic control of radioactive effluents from the chimney of the RP-10 reactor, using as hardware an Arduino UNO platform containing an ATMEGA 328 programmable micro controller to which has been added LCD screen to display the values, a keyboard and an EEPROM memory data, where the limit of the level of radiation is fixed. The radiation level in the air of the reactor hall, going up the chimney is counted by a radiation monitor called MAB1000, and data are supplied to the new system. When the radiation level is above the national and international standards, the new design makes work a relay, so that the ventilation system is automatically switched to operate in emergency condition, preventing the release of radioactive contaminants into the environment. After installing the new design, it was verified that removed by the radiation monitor MAB1000, value is identical to that shown in the new system. Additionally, the operation of the relay was tested successfully with radioactive sources to switch the ventilation system to the emergency condition. (authors).

  14. Individually ventilated cages impose cold stress on laboratory mice: a source of systemic experimental variability.

    Science.gov (United States)

    David, John M; Knowles, Scott; Lamkin, Donald M; Stout, David B

    2013-11-01

    Individual ventilated cages (IVC) are increasing in popularity. Although mice avoid IVC in preference testing, they show no aversion when provided additional nesting material or the cage is not ventilated. Given the high ventilation rate in IVC, we developed 3 hypotheses: that mice housed in IVC experience more cold stress than do mice housed in static cages; that IVC-induced cold stress affects the results of experiments using mice; and that, when provided shelters, mice behaviorally thermoregulate and thereby rescue the cold-stress effects of IVC. To test these hypotheses, we housed mice in IVC, IVC with shelters, and static cages maintained at 20 to 21 °C. We quantified the cold stress of each housing system on mice by assessing nonshivering thermogenesis and brown adipose vacuolation. To test housing effects in a common, murine model of human disease, we implanted mice with subcutaneous epidermoid carcinoma cells and quantified tumor growth, tumor metabolism, and adrenal weight. Mice housed in IVC had histologic signs of cold stress and significantly higher nonshivering thermogenesis, smaller subcutaneous tumors, lower tumor metabolism, and larger adrenal weights than did mice in static cages. Shelters rescued IVC-induced nonshivering thermogenesis, adrenal enlargement, and phenotype-dependent cold-mediated histologic changes in brown adipose tissue and tumor size. IVC impose chronic cold stress on mice, alter experimental results, and are a source of systemic confounders throughout rodent-dependent research. Allowing mice to exhibit behavioral thermoregulation through seeking shelter markedly rescues the experiment-altering effects of housing-imposed cold stress, improves physiologic uniformity, and increases experimental reproducibility across housing systems.

  15. Closure Report for Corrective Action Unit 262: Area 25 Septic Systems and Underground Discharge Point, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    Tobiason, D. S.

    2003-01-01

    This Closure Report (CR) documents the activities undertaken to close Corrective Action Unit (CAU) 262: Area 25 Septic Systems and Underground Discharge Point, in accordance with the Federal Facility Agreement and Consent Order (FFACO) of 1996. Site closure was performed in accordance with the Nevada Division of Environmental Protection (NDEP)-approved Corrective Action Plan (CAP) for CAU 262 (U.S. Department of Energy, National Nuclear Security Administration Nevada Operations Office [NNSA/NV, 2002a]). CAU 262 is located at the Nevada Test Site (NTS) approximately 105 kilometers (65 miles) northwest of Las Vegas, Nevada. CAU 262 consists of the following nine Corrective Action Sites (CASs) located in Area 25 of the NTS: CAS 25-02-06, Underground Storage tank CAS 25-04-06, Septic Systems A and B CAS 25-04-07, Septic System CAS 25-05-03, Leachfield CAS 25-05-05, Leachfield CAS 25-05-06, Leachfield CAS 25-05-08, Radioactive Leachfield CAS 25-05-12, Leachfield CAS 25-51-01, Dry Well

  16. Heat pipes as perspective base elements of heat recovery in heat supply and ventilating systems

    Directory of Open Access Journals (Sweden)

    Matveev Andrey

    2017-01-01

    Full Text Available Thermotechnical characteristics of heat pipes are considered as high-efficient heat-transfer devices, which can provide energy-saving technologies for heat supply and ventilating systems and for different branches of industry. Thermotechnical and working (”performance capability” characteristics of heat pipes are investigated. By ”performance capability” of heat pipes and heat-transfer devices on heat pipes we mean the system state, where it can perform set functions and keep parameter values (thermal power, conductivity, thermal resistance, heat-transfer coefficient, temperature level and differential, etc. within the regulations of standardized specifications. The article presents theoretical and experimental methods of «gaslock» length determination on noncondensable gases during long-lasting tests of ammonia heat pipes made of aluminum shape АS – КRА 7.5 – R1 (alloy АD – 31. The paper gives results of research of thermotechnical characteristics of heat pipes in horizontal and vertical states (separate and as a set part while using different systems of thermal insulation. The obtained results of thermotechnical and resource tests show the advantages of ammonia heat pipes as basic elements for heat exchanger design in heating and ventilation systems.

  17. Applications and Energy Consumption of Demand Controlled Ventilation Systems. Modelling, Simulation and Implementation of Modular Built Dynamical VAV Systems and Control Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, Bjoern R.

    2002-07-01

    This thesis discusses many topics of heating and ventilation. This is because the ventilation system is an integrated part of its host building. The functionality and effectiveness of the ventilation system are very much dependent on the building's architectural design, its internal materials, its occupants, its air tightness characteristics and its placement in the terrain. Although this thesis emphasizes strongly on VAV (Variable Air Volume) systems and, in particular, modelling and simulation of such systems, it touches a range of important HVAC related issues. The scope is however, limited to the field of comfort ventilation. That is because ventilation in industrial environments often is subject to separate regulations, and requires other and specialized methods of design and evaluation of ventilation performance. The main objectives have been to: (1) Develop mathematical models for VAV components and systems. (2) Evaluate existing and develop new strategies for VAV demand controlled ventilation by system simulation. (3) Investigate the potential for saving energy and the impact on indoor climate. The development of mathematical models and simulation of VAV systems are given quite much attention compared to the other topics discussed.

  18. Duct corrosion in the ventilating air conditioning system for Main Control Room

    International Nuclear Information System (INIS)

    Yamada, Kohei; Kobayashi, Takashi; Minami, Akiko; Fukuba, Kazushi

    2014-01-01

    Higashidori Nuclear Power Station, start-of-operation in December 2005, is a relatively new plant. We decided to get original data of air duct condition to determine maintenance policy of air duct, because planned maintenance of air duct has never been done and the corrosion of air duct has occurred in other plant. In January 2014, we found a corrosion-hole at the downstream of the inlet damper in the ventilating air conditioning system for Main Control Room (MCR). We supposed that the cause of rapid corrosion is related to the characteristic environment of this site. (author)

  19. An assessment of a partial pit ventilation system to reduce emission under slatted floor

    DEFF Research Database (Denmark)

    Wu, Wentao; Zhang, Guoqiang; Bjerg, Bjarne Schmidt

    2012-01-01

    of measured and calculated removal ratios were found for most of cases. It was feasible to use RSM to predict the removal capability. The future research should focus on depicting the airflow patterns inside the pit by using scale model under well controlled laboratory conditions and generating benchmark data...... to validate and improve CFD methods. Unsteady CFD simulation using large eddy simulation could be conducted to make more precise predictions of removal capability of the partial pit ventilation system by considering the unsteady phenomena of gas emission....

  20. Control and prevention of ice formation and accretion on heat exchangers for ventilation systems

    DEFF Research Database (Denmark)

    Rahimi, Maral; Afshari, Alireza

    2015-01-01

    In cold climates, the application of mechanical ventilation systems with heat recovery like are airto-air exchangers is used for reducing energy consumption for heating buildings by transferring heat exhausted air to supply air. However, increase efficiency of heat exchanger results in lower...... exhaust air temperatures and Ice formation on heat exchanger fins, which can cause problem and is not favourable. Therefore, prevention and control of ice formation on heat exchangers is necessary. The existing methods are divided into two different methods: active and passive ice control methods...

  1. INFLUENCE OF APPLYING ADDITIONAL FORCING FANS FOR THE AIR DISTRIBUTION IN VENTILATION NETWORK

    Directory of Open Access Journals (Sweden)

    Nikodem SZLĄZAK

    2016-07-01

    Full Text Available Mining progress in underground mines cause the ongoing movement of working areas. Consequently, it becomes neces-sary to adapt the ventilation network of a mine to direct airflow into newly-opened districts. For economic reasons, opening new fields is often achieved via underground workings. Length of primary intake and return routes increases and also increases the total resistance of a complex ventilation network. The development of a subsurface structure can make it necessary to change the air distribution in a ventilation network. Increasing airflow into newly-opened districts is necessary. In mines where extraction does not entail gas-related hazards, there is possibility of implementing a push-pull ventilation system in order to supplement airflows to newly developed mining fields. This is achieved by installing sub-surface fan stations with forcing fans at the bottom of downcast shaft. In push-pull systems with multiple main fans, it is vital to select forcing fans with characteristic curves matching those of the existing exhaust fans to prevent undesirable mutual interaction. In complex ventilation networks it is necessary to calculate distribution of airflow (especially in net-works with a large number of installed fans. In the article the influence of applying additional forcing fans for the air distribution in ventilation network for underground mine were considered. There are also analysed the extent of over-pressure caused by the additional forcing fan in branches of the ventilation network (the operating range of additional forcing fan. Possibilities of increasing airflow rate in working areas were conducted.

  2. Displacement ventilation

    DEFF Research Database (Denmark)

    Kosonen, Risto; Melikov, Arsen Krikor; Mundt, Elisabeth

    The aim of this Guidebook is to give the state-of-the art knowledge of the displacement ventilation technology, and to simplify and improve the practical design procedure. The Guidebook discusses methods of total volume ventilation by mixing ventilation and displacement ventilation and it gives...... insights of the performance of the displacement ventilation. It also shows practical case studies in some typical applications and the latest research findings to create good local micro-climatic conditions....

  3. An Event Reporting and Early-Warning Safety System Based on the Internet of Things for Underground Coal Mines: A Case Study

    Directory of Open Access Journals (Sweden)

    Byung Wan Jo

    2017-09-01

    Full Text Available Fatal accidents associated with underground coal mines require the implementation of high-level gas monitoring and miner’s localization approaches to promote underground safety and health. This study introduces a real-time monitoring, event-reporting and early-warning platform, based on cluster analysis for outlier detection, spatiotemporal statistical analysis, and an RSS range-based weighted centroid localization algorithm for improving safety management and preventing accidents in underground coal mines. The proposed platform seamlessly integrates monitoring, analyzing, and localization approaches using the Internet of Things (IoT, cloud computing, a real-time operational database, application gateways, and application program interfaces. The prototype has been validated and verified at the operating underground Hassan Kishore coal mine. Sensors for air quality parameters including temperature, humidity, CH4, CO2, and CO demonstrated an excellent performance, with regression constants always greater than 0.97 for each parameter when compared to their commercial equivalent. This framework enables real-time monitoring, identification of abnormal events (>90%, and verification of a miner’s localization (with <1.8 m of error in the harsh environment of underground mines. The main contribution of this study is the development of an open source, customizable, and cost-effective platform for effectively promoting underground coal mine safety. This system is helpful for solving the problems of accessibility, serviceability, interoperability, and flexibility associated with safety in coal mines.

  4. Noninvasive ventilation for acute respiratory distress in children with central nervous system disorders.

    Science.gov (United States)

    Falsaperla, Raffaele; Elli, Marco; Pavone, Piero; Isotta, Gentile; Lubrano, Riccardo

    2013-09-01

    Acute respiratory distress (ARD) is a relatively frequent occurrence in patients suffering from central nervous system disorders (CNSD) and moderate to severe mental retardation. Whenever conventional therapy is little effective, noninvasive mechanical ventilation (NIV) is the additional treatment in patients with diseases of the peripheral nervous system. However, NIV is traditionally little employed in the acute phase in patients suffering from CNSD. In the latter, either conventional therapy is maintained or invasive mechanical ventilation is instituted if the patient's condition worsens severely. To challenge the traditional view, we conducted the study to prove that NIV is both applicable and effective in the treatment of ARD also in children with moderate to severe mental retardation. We studied 44 children with ARD secondary to pneumonia and CNSD causing moderate to severe mental retardation. The children were divided in two groups. One group received conventional therapy and NIV, the other conventional therapy only, before being advanced to invasive ventilator support when nonresponding. On admission to hospital and one hour following admission we registered pH, PaCO(2), PaO2, A - a DO2 and the PaO2/FiO2 ratio. The mean hospital stay was also recorded. After one hour on NIV PaO2 and pH increased, PaCO(2) decreased, A - a DO2 and PaO2/FiO2 ratio improved. No changes in the above parameters were observed in children on conventional therapy only. Hospital stay was shorter when NIV was instituted. NIV is both applicable and beneficial in stabilizing blood gases, respiratory and cardiovascular parameters also in children with CNSD. Moreover its use shortens the hospital stay. © 2013 Elsevier Ltd. All rights reserved.

  5. Flow requirements and rebreathing during mechanically controlled ventilation in a T-piece (Mapleson E) system.

    Science.gov (United States)

    Hatch, D J; Yates, A P; Lindahl, S G

    1987-12-01

    The influence of fresh gas flow (FGF) setting on rebreathing was investigated in 15 infants and children (weight 3.5-21.8 kg) during balanced anaesthesia with mechanically controlled ventilation using a T-piece (Mapleson E) system and a Nuffield ventilator 200. Tidal volume (VT), minute volume (VE), maximal inspired (PICO2) and end-tidal (PE'CO2) carbon dioxide tensions and airway pressure were measured. VE, set to produce a PE'CO2 of about 4.5 kPa and measured at a high FGF (minimal rebreathing), was unchanged throughout the study and the regression equation for VE and weight was: VE (ml min-1) = 146 x kg + 482, r = 0.92. Measurements were then repeated at FGF:VE ratios reduced to 1.5 and 1.0. To achieve minimal rebreathing (PICO2 less than 0.5 kPa), FGF:VE ratios greater than 1.8 (range 1.8-4.9) had to be used. At FGF:VE ratios of 1.5, some alveolar rebreathing occurred, indicated by increased inspired (P less than 0.001) and end-tidal (P less than 0.001) carbon dioxide tensions. At FGF:VE ratios equal to 1.0, alveolar rebreathing was more pronounced and hypercapnoea occurred with a PE'CO2 (mean +/- 1 SD) of 5.89 +/- 0.53 kPa. At this FGF setting, change in I:E ratio from 1:2 to 1:1 did not influence the level of alveolar rebreathing. A minimal FGF (ml min-1) setting of 1.5 x VE (that is, 1.5 (146 x kg + 482), approximated to the expression (200 x kg + 1000) is recommended for controlled ventilation to avoid hypercapnoea when using the T-piece system in children weighing less than 20 kg.

  6. Comparison of a Constant Air Volume (CAV) and a Demand Controlled Ventilation (DCV) System in a Residential Building

    DEFF Research Database (Denmark)

    Mortensen, Dorthe Kragsig; Nielsen, Toke Rammer; Topp, Claus

    2008-01-01

    The aim of this paper was to compare the indoor climate and the energy performance of a Constant Air Volume (CAV) system of 0.5h-1 with a Demand Controlled Ventilation (DCV) system controlled by occupancy and relative humidity for a studio apartment. Furthermore the impact of building materials...... it was found that the energy consumption for heating and operating the ventilation system could be reduced by respectively 8.0% and 10.6 % in the case of DCV without negative impact on the indoor climate. Including the hygroscopic properties of the materials resulted in a reduction of the energy consumption...... for heating and operating the ventilation system by respectively 9.5% and 17.1 % in favour of the DCV system....

  7. Accessing leaking underground storage tank case studies and publications through the EPA's Computerized On-Line Information System (COLIS)

    International Nuclear Information System (INIS)

    Hillger, R.; Tibay, P.

    1991-01-01

    The US EPA's regulations for underground storage tanks (USTs) require corrective action to be taken in response to leaking USTs. Recent developments of UST programs nationwide as well as the introduction of new technologies to clean up UST sites have increased the diversity of experience levels among personnel involved with this type of work. The EPA's Computerized On-Line Information System (COLIS) has been developed to facilitate technology transfer among the personnel involved in UST cleanup. The system allows for the quick and simple retrieval of data relating to UST incidents, as well as other hazardous waste-related information. The system has been used by response personnel at all levels of government, academia, and private industry. Although it has been in existence for many years, users are just now realizing the potential wealth of information stored in this system. COLIS access can be accomplished via telephone lines utilizing a personal computer and a modem

  8. Ventilation systems analysis during tornado conditions. Progress report, January--June 1975

    International Nuclear Information System (INIS)

    Bennett, G.A.; Gregory, W.S.; Smith, P.R.

    1975-11-01

    The principal concern of this investigation is to develop the capability to simulate the dynamic effects of a tornado depressurization on a ventilation system. The basic formulation and solution of the two-zone series model ventilation subsystem is based on lumped parameter component response equations, the isothermal compression of air, and the conservation of mass. Solutions based on these assumptions are also presented for the two-zone series model with natural bypass, the two-zone series model with recirculation, and the natural branching model. A parameter study is presented comparing the effects of changes in system resistance, system capacitance, and variable tornado depressurization rates. The adaptability of the basic formulation to adiabatic compression of air and the addition of duct resistance is examined. A quasi-steady formulation is introduced and preliminary considerations of the importance of inertia are presented. Preliminary conclusions in this area indicate that inertial effects can be neglected. For relatively long ducts slow shock development appears possible. Work on the effect of tornado depressurization rates as related to shock development and on the importance of inertia effects is continuing

  9. Exploration Mission Particulate Matter Filtration Technology Performance Testing in a Simulated Spacecraft Cabin Ventilation System

    Science.gov (United States)

    Agui, Juan H.; Vijayakumar, R.; Perry, Jay L.; Frederick, Kenneth R.; Mccormick, Robert M.

    2017-01-01

    Human deep space exploration missions will require advances in long-life, low maintenance airborne particulate matter filtration technology. As one of the National Aeronautics and Space Administrations (NASA) developments in this area, a prototype of a new regenerable, multi-stage particulate matter filtration technology was tested in an International Space Station (ISS) module simulation facility. As previously reported, the key features of the filter system include inertial and media filtration with regeneration and in-place media replacement techniques. The testing facility can simulate aspects of the cabin environment aboard the ISS and contains flight-like cabin ventilation system components. The filtration technology test article was installed at the inlet of the central ventilation system duct and instrumented to provide performance data under nominal flow conditions. In-place regeneration operations were also evaluated. The real-time data included pressure drop across the filter stages, process air flow rate, ambient pressure, humidity and temperature. In addition, two video cameras positioned at the filtration technology test articles inlet and outlet were used to capture the mechanical performance of the filter media indexing operation under varying air flow rates. Recent test results are presented and future design recommendations are discussed.

  10. Ventilation of uranium mines

    International Nuclear Information System (INIS)

    Francois, Y.; Pradel, J.; Zettwoog, P.; Dumas, M.

    1975-01-01

    In the first part of the paper the authors describe the ventilation of French mines in terms of the primary ventilation system, which brings the outside air close to the working places using the overall structure of the mine to form the airways, and the secondary ventilation system, which is for the distribution of the primary air or for the ventilation of the development drifts and blind tunnels. Brief mention is made of the French regulations on the ventilation of mines in general and uranium mines in particular. The authors describe the equipment used and discuss the installed capacities and air flow per man and per working place. The difficulties encountered in properly ventilating various types of working places are mentioned, such as sublevel development drifts, reinforced stopes, and storage chambers with an artificial crown. The second part of the paper is devoted to computer calculations of the primary ventilation system. It is explained why the Commissariat a l'energie atomique has found it necessary to make these calculations. Without restating the mathematical theories underlying the methods employed, the authors demonstrate how simple measuring instruments and a small-size computer can be used to solve the ventilation problems arising in French mines. Emphasis is given to the layout of the ventilation system and to air flow and negative pressure measurements at the base of the mine. The authors show how calculations can be applied to new heading operations, a change in resistance, the replacement or addition of a ventilator, and a new air inlet or outlet. The authors come to the conclusion that since ventilation is at present the most reliable way of avoiding the pollution of mines, a thorough knowledge of the capabilities in this respect can often help improve working conditions. Despite the progress made, however, constant surveillance of the ventilation systems in uranium mines by a separate team with no responsibility for production problems is

  11. The effects of spatial variability of the aggressiveness of soil on system reliability of corroding underground pipelines

    International Nuclear Information System (INIS)

    Sahraoui, Yacine; Chateauneuf, Alaa

    2016-01-01

    In this paper, a probabilistic methodology is presented for assessing the time-variant reliability of corroded underground pipelines subjected to space-variant soil aggressiveness. The Karhunen-Loève expansion is used to model the spatial variability of soil as a correlated stochastic field. The pipeline is considered as a series system for which the component and system failure probabilities are computed by Monte Carlo simulations. The probabilistic model provides a realistic time and space modelling of stochastic variations, leading to appropriate estimation of the lifetime distribution. The numerical analyses allow us to investigate the impact of various parameters on the reliability of underground pipelines, such as the soil aggressiveness, the pipe design variables, the soil correlation length and the pipeline length. The results show that neglecting the effect of spatial variability leads to pessimistic estimation of the residual lifetime and can lead to condemn prematurely the structure. - Highlights: • The role of soil heterogeneity in pipeline reliability assessment has been shown. • The impact of pipe length and soil correlation length has been examined. • The effect of the uncertainties related to design variables has been observed. • Pipe thickness design for homogeneous reliability has been proposed.

  12. Ventilation onset prior to umbilical cord clamping (physiological-based cord clamping improves systemic and cerebral oxygenation in preterm lambs.

    Directory of Open Access Journals (Sweden)

    Graeme R Polglase

    Full Text Available As measurement of arterial oxygen saturation (SpO2 is common in the delivery room, target SpO2 ranges allow clinicians to titrate oxygen therapy for preterm infants in order to achieve saturation levels similar to those seen in normal term infants in the first minutes of life. However, the influence of the onset of ventilation and the timing of cord clamping on systemic and cerebral oxygenation is not known.We investigated whether the initiation of ventilation, prior to, or after umbilical cord clamping, altered systemic and cerebral oxygenation in preterm lambs.Systemic and cerebral blood-flows, pressures and peripheral SpO2 and regional cerebral tissue oxygenation (SctO2 were measured continuously in apnoeic preterm lambs (126±1 day gestation. Positive pressure ventilation was initiated either 1 prior to umbilical cord clamping, or 2 after umbilical cord clamping. Lambs were monitored intensively prior to intervention, and for 10 minutes following umbilical cord clamping.Clamping the umbilical cord prior to ventilation resulted in a rapid decrease in SpO2 and SctO2, and an increase in arterial pressure, cerebral blood flow and cerebral oxygen extraction. Ventilation restored oxygenation and haemodynamics by 5-6 minutes. No such disturbances in peripheral or cerebral oxygenation and haemodynamics were observed when ventilation was initiated prior to cord clamping.The establishment of ventilation prior to umbilical cord clamping facilitated a smooth transition to systemic and cerebral oxygenation following birth. SpO2 nomograms may need to be re-evaluated to reflect physiological management of preterm infants in the delivery room.

  13. Ventilation onset prior to umbilical cord clamping (physiological-based cord clamping) improves systemic and cerebral oxygenation in preterm lambs.

    Science.gov (United States)

    Polglase, Graeme R; Dawson, Jennifer A; Kluckow, Martin; Gill, Andrew W; Davis, Peter G; Te Pas, Arjan B; Crossley, Kelly J; McDougall, Annie; Wallace, Euan M; Hooper, Stuart B

    2015-01-01

    As measurement of arterial oxygen saturation (SpO2) is common in the delivery room, target SpO2 ranges allow clinicians to titrate oxygen therapy for preterm infants in order to achieve saturation levels similar to those seen in normal term infants in the first minutes of life. However, the influence of the onset of ventilation and the timing of cord clamping on systemic and cerebral oxygenation is not known. We investigated whether the initiation of ventilation, prior to, or after umbilical cord clamping, altered systemic and cerebral oxygenation in preterm lambs. Systemic and cerebral blood-flows, pressures and peripheral SpO2 and regional cerebral tissue oxygenation (SctO2) were measured continuously in apnoeic preterm lambs (126±1 day gestation). Positive pressure ventilation was initiated either 1) prior to umbilical cord clamping, or 2) after umbilical cord clamping. Lambs were monitored intensively prior to intervention, and for 10 minutes following umbilical cord clamping. Clamping the umbilical cord prior to ventilation resulted in a rapid decrease in SpO2 and SctO2, and an increase in arterial pressure, cerebral blood flow and cerebral oxygen extraction. Ventilation restored oxygenation and haemodynamics by 5-6 minutes. No such disturbances in peripheral or cerebral oxygenation and haemodynamics were observed when ventilation was initiated prior to cord clamping. The establishment of ventilation prior to umbilical cord clamping facilitated a smooth transition to systemic and cerebral oxygenation following birth. SpO2 nomograms may need to be re-evaluated to reflect physiological management of preterm infants in the delivery room.

  14. COSTEAU - preheating and cooling by means of underground collectors with water circulation - case study (Perret building at Satigny, Geneva) and generalisation; COSTEAU. Prechauffage et rafraichissement par collecteurs souterrains a eau. Etude de cas (batiment Perret a Satigny, Geneve) et generalisation

    Energy Technology Data Exchange (ETDEWEB)

    Hollmuller, P.; Lachal, B.

    2003-07-01

    Since a couple of years, underground collectors with air circulation have been becoming increasingly popular as a simple means for preheating (at winter time) and cooling (at summer time) of outdoor air ahead of a ventilation system for well insulated buildings. This report considers underground collectors with water circulation used for similar purposes. They are connected to the ventilation system via an air/water heat exchanger. Starting from a case study - one-year detailed in-situ measurements and data analysis from an air-heated office building near Geneva, Switzerland - computerised simulations have been performed as a sensitivity analysis tool as well as to establish recommendations and sizing rules for planners, including cost considerations. In the case study it turned out that the water-circulated underground collector, which is installed right under the basement of this well insulated building, is in thermal contact with the basement. Its main function is to damp the daily temperature oscillation of the inlet ventilation air, bringing the expected thermal comfort improvement in the summer time. However, this underground collector is unable to collect seasonally stored heat from the ground. Hence, in the winter time the main preheating contribution arises from the series-connected heat-recovery unit from the exit air. Numerical simulations show that optimal sizing of underground collectors is essential, and that both the underground collector and the well insulated building as a physical system with thermal inertia have to be simultaneously considered in the optimization process. Optimization also has to include parasitic energy (electricity) needed by fans and pumps. As outdoor air inlet can never be flooded in the case of underground collectors with water circulation the sanitary risk encountered with air-circulated underground collectors does not exist for them. Initial investment cost for water-circulated underground collectors is higher than for a

  15. A decision support system framework to improve design-construction integration and project performance on public sector underground utility projects

    Science.gov (United States)

    Gehrig, Gary Bruce

    One of the noted difficulties with the traditional public works project development process is the lack of integration and sharing of information between engineering and construction entities that results in a decrease in project performance. To improve project performance on public sector underground utility projects, the research develops a decision support system framework that enhances the exchange and integration of relevant information and knowledge between entities on such projects by incorporating a lessons-learned database to document, organize and disseminate lessons-learned on a project. To identify the critical activities within the project development process that could be linked to the decision support system, the Integration Definition for Functioning Modeling (IDEFO) technique was used to create a representative model of the public works project development process. The resultant model demonstrated the repeatable nature of the process both across project phases and from project-to-project and identified the decision-making activities of generating and evaluating alternatives as key opportunities for construction-related input that could be linked to a decision support system. An inspection of current industry practices was conducted through interviews with knowledgeable industry sources to determine the scope of the decision support system framework. Results revealed the type of critical decisions on underground utility projects that could benefit from construction-related input and identified the documentation of lessons-learned as a major industry weakness. A prototype decision support system incorporating a lessons-learned database was developed and the framework integrated into common project management reporting mechanisms found in the industry. The actual decision-maker can retrieve lessons-learned according to predetermined categories of critical decisions, compare and evaluated retrieved alternatives, and document the rationale behind the

  16. Multifamily Ventilation Retrofit Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K.; Lstiburek, J.; Bergey, D.

    2012-12-01

    In multifamily buildings, central ventilation systems often have poor performance, overventilating some portions of the building (causing excess energy use), while simultaneously underventilating other portions (causing diminished indoor air quality). BSC and Innova Services Corporation performed a series of field tests at a mid-rise test building undergoing a major energy audit and retrofit, which included ventilation system upgrades.

  17. Nuclear power plant control room ventilation system design for meeting general criterion 19

    International Nuclear Information System (INIS)

    Murphy, K.G.; Campe, K.M.

    1975-01-01

    The requirement for protection of control room personnel against radiation is specified in General Design Criterion 19 of Appendix A, 10 CFR Part 50. The evaluation of a control room design, especially its emergency ventilation system, with respect to radiation protection primarily consists of determining the radiation doses to control room personnel under accident conditions. The accident dose assessment involves modeling and evaluation of radiological source terms, atmospheric transport of airborne activity, and protection features of the control room ventilation system. Some of the assumptions and conservatisms used in the dose analyses are based on the technical review experience of existing or proposed control room designs. A review of over 50 control room designs has revealed a great variety of design concepts, not all of which seem to have been based on radiation protection criteria. A summary of the basic control room protection requirements, design features, dose acceptance criteria, and an outline of the methods used by the Regulatory staff for accident dose evaluation are presented. (U.S.)

  18. Booster fans : some considerations for their usage in underground coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Gillies, S.; Slaughter, C. [Missouri Univ. of Science and Technology, Rolla, MO (United States); Calizaya, F. [Utah Univ., Salt Lake City, UT (United States); Wu, H.W. [Gillies Wu Mining Technology Pty Ltd., Brisbane, QLD (Australia)

    2010-07-01

    This paper reported on a study that investigated the conditions under which booster fans can be used safely and efficiently in underground coal mines. Booster fans are installed in series with a main surface fan and are used to boost the air pressure of the ventilation air passing through it. Several coal mining countries use booster fans, but in the United States, they are only used in metal/non-metal mines due to concerns of uncontrolled recirculation. This study investigated installations of booster fans in non-US underground coal mines where safe and efficient atmospheric conditions are achieved. The purpose was to collect reliable information on airway resistances and flow requirements typical in large US coal mines. The study showed that safe booster fan installations are found in both high and low gas conditions, and sometimes where workings are located at great depths. The interlocking systems within the booster fan can control the underground fans and avoid recirculation when surface fans are unexpectedly turned off. Another purpose of the study was to determine when booster fans become a more viable solution in coal mines due to increases in air requirements at higher production rates. It was concluded that a new fan selection algorithm to produce recirculation-free ventilation designs will be developed to enable US coal mine operators to develop ventilation designs to extract coal seams from depths greater than 1000 m. 17 refs., 1 fig.

  19. Effect of central ventilation and air conditioner system on the concentration and health risk from airborne polycyclic aromatic hydrocarbons.

    Science.gov (United States)

    Lv, Jinze; Zhu, Lizhong

    2013-03-01

    Central ventilation and air conditioner systems are widely utilized nowadays in public places for air exchange and temperature control, which significantly influences the transfer of pollutants between indoors and outdoors. To study the effect of central ventilation and air conditioner systems on the concentration and health risk from airborne pollutants, a spatial and temporal survey was carried out using polycyclic aromatic hydrocarbons (PAHs) as agent pollutants. During the period when the central ventilation system operated without air conditioning (AC-off period), concentrations of 2-4 ring PAHs in the model supermarket were dominated by outdoor levels, due to the good linearity between indoor air and outdoor air (r(p) > 0.769, p ventilating like the model supermarket increased the potential health risks from low molecular weight PAHs. During the period when the central ventilation and air conditioner systems were working simultaneously (AC-on period), although the total levels of PAHs were increased, the concentrations and percentage of the particulate PAHs indoors declined significantly. The BaP equivalency (BaPeq) concentration indicated that utilization of air conditioning reduced the health risks from PAHs in the model supermarket.

  20. Evaluation of optimal dual axis concentrated photovoltaic thermal system with active ventilation using Frog Leap algorithm

    International Nuclear Information System (INIS)

    Gholami, H.; Sarwat, A.I.; Hosseinian, H.; Khalilnejad, A.

    2015-01-01

    Highlights: • Electro-thermal performance of open-loop controlled dual axis CPVT is investigated. • For using the absorbed heat, active ventilation with a heat storage tank is used. • Economic optimization of the system is performed, using Frog Leap algorithm. • Detailed model of all sections is simulated with their characteristics evaluation. • Triple-junction photovoltaic cells, which are the most recent technology, are used. - Abstract: In this study, design and optimization of a concentrated photovoltaic thermal (CPVT) system considering electrical, mechanical, and economical aspects is investigated. For this purpose, each section of the system is simulated in MATLAB, in detail. Triple-junction photovoltaic cells, which are the most recent technology, are used in this study. They are more efficient in comparison to conventional photovoltaic cells. Unlike ordinary procedures, in this work active ventilation is used for absorbing the thermal power of radiation, using heat storage tanks, which not only results in increasing the electrical efficiency of the system through decreasing the temperature, but also leads to storing and managing produced thermal energy and increasing the total efficiency of the system up to 85 percent. The operation of the CPVT system is investigated for total hours of the year, considering the needed thermal load, meteorological conditions, and hourly radiation of Khuznin, a city in Qazvin province, Iran. Finally, the collector used for this system is optimized economically, using frog leap algorithm, which resulted in the cost of 13.4 $/m 2 for a collector with the optimal distance between tubes of 6.34 cm.

  1. The LoTrach system: its role in the prevention of ventilator-associated pneumonia.

    Science.gov (United States)

    Fletcher, Andrew J W; Ruffell, Alison J; Young, Peter J

    2008-01-01

    To discuss the development of the LoTrach system in light of current evidence around the prevention of ventilator-associated pneumonia (VAP) and its practical application in the intensive care setting. VAP causes substantial morbidity and mortality in ventilated patients in the Intensive Care Unit (ICU), increases length of stay in ICU and is extremely costly. Strategies are needed to reduce the risk of VAP. We examine the need for an endotracheal tube (ETT) specifically designed for the critically-ill patient, the development of the LoTrach system from conception to production, and the role of the various components of the system in preventing VAP. Early issues in implementing this revolutionary equipment into ICU are explored and three case studies highlight advantages of this system. The LoTrach system has been designed to facilitate the provision of a number of evidence-based interventions that have been shown to reduce VAP. Pulmonary aspiration is ubiquitous with conventional cuffs but prevented by the cuff of the LoTrach system when held at a constant and safe pressure against the tracheal wall with a cuff pressure controller. Other aspects incorporated in the ETT are aimed at clearing the secretions from the subglottic space, preventing tube occlusion and accidental extubation, and avoiding damage to the airway. In this way the LoTrach system employs a multifactorial approach to the prevention of VAP and the cost savings from LoTrach rather than a standard ETT will be considerable because of an average 3 day reduction in ICU length of stay related to this. It thus has the potential to be a very useful tool in the ICU setting in the prevention of VAP.

  2. Spectacular test of the fire extinguishing system in the underground cavern of the CMS experiment

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    The enormous rumbling heard 100 m under the earth on Friday, 12 May, was not the start of a foam party at CMS. The Safety Team looked on from the second tier of the CMS underground cavern as it reechoed to the sound of water rushing through the two huge pipes overhead and the air was filled with a mixture of water and foam. A minute later it was a winter wonderland, as fluffy puffs of foam came shooting out of the twelve foam blowers lining the upper cavern walls on both sides. In less than two minutes 7 m3 of water mixed with a small percentage of foaming liquid, was transformed into 5600 m3 of foam and discharged into the cavern.

  3. Evaluation of Underground Zinc Mine Investment Based on Fuzzy-Interval Grey System Theory and Geometric Brownian Motion

    Directory of Open Access Journals (Sweden)

    Zoran Gligoric

    2014-01-01

    Full Text Available Underground mine projects are often associated with diverse sources of uncertainties. Having the ability to plan for these uncertainties plays a key role in the process of project evaluation and is increasingly recognized as critical to mining project success. To make the best decision, based on the information available, it is necessary to develop an adequate model incorporating the uncertainty of the input parameters. The model is developed on the basis of full discounted cash flow analysis of an underground zinc mine project. The relationships between input variables and economic outcomes are complex and often nonlinear. Fuzzy-interval grey system theory is used to forecast zinc metal prices while geometric Brownian motion is used to forecast operating costs over the time frame of the project. To quantify the uncertainty in the parameters within a project, such as capital investment, ore grade, mill recovery, metal content of concentrate, and discount rate, we have applied the concept of interval numbers. The final decision related to project acceptance is based on the net present value of the cash flows generated by the simulation over the time project horizon.

  4. The ground-water system and possible effects of underground coal mining in the Trail Mountain area, central Utah

    Science.gov (United States)

    Lines, Gregory C.

    1985-01-01

    The ground-water system was studied in the Trail Mountain area in order to provide hydrologic information needed to assess the hydrologic effects of underground coal mining. Well testing and spring data indicate that water occurs in several aquifers. The coal-bearing Blackhawk-Star Point aquifer is regional in nature and is the source of most water in underground mines in the region. One or more perched aquifers overlie the Blackhawk-Star Point aquifer in most areas of Trail Mountain.Aquifer tests indicate that the transmissivity of the Blackhawk-Star Point aquifer, which consists mainly of sandstone, siltstone, and shale, ranges from about 20 to 200 feet squared per day in most areas of Trail Mountain. The specific yield of the aquifer was estimated at 0.05, and the storage coefficient is about IxlO"6 per foot of aquifer where confined.The main sources of recharge to the multiaquifer system are snowmelt and rain, and water is discharged mainly by springs and by leakage along streams. Springs that issue from perched aquifers are sources of water for livestock and wildlife on Trail Mountain.Water in all aquifers is suitable for most uses. Dissolved solids concentrations range from about 250 to 700 milligrams per liter, and the predominant dissolved constituents generally are calcium, magnesium, and bicarbonate. Future underground coal mines will require dewatering when they penetrate the Blackhawk-Star Point aquifer. A finitedifference, three-dimensional computer model was used to estimate the inflow of water to various lengths and widths of a hypothetical dewatered mine and to estimate drawdowns of potentiometric surfaces in the partly dewatered aquifer. The estimates were made for a range of aquifer properties and premining hydraulic gradients that were similar to those on Trail Mountain. The computer simulations indicate that mine inflows could be several hundred gallons per minute and that potentiometric surfaces of the partly dewatered aquifer could be drawn

  5. Influence of paravertebral miorelaxant on arbitrary maximal ventilation of respirators system at skilled sportsmen

    Directory of Open Access Journals (Sweden)

    Syshko D.V.

    2012-09-01

    Full Text Available The functional being of the respirator system of the skilled sportsmen, engaged in the greco-roman fight (n=22, heavy athletics (n=25 and football (n=24 before and after course of paravertebral miorelaxant, is studied. The course of paravertebral miorelaxant was the system of exercises in a water environment with the use of «noodle». The necessity of application of correction influences, for sportsmen, was conditioned by the presence of hypertonic of paravertebral muscles, registered through miotonometric. It is got, those parameters of arbitrary maximal ventilation of respirators system (MVR, after the course of paravertebral miorelaxant, changed depending on the orientation of the training process determined by the type of sport. It is certain, whatever the change of tone of paravertebral muscles renders the reliable changes in the structure of arbitrary MVL at footballers, for certain affects chronotropics to the component at heavy athletics and inotropics at the representatives of the greco-roman fight.

  6. An example of a component replacement when applying ASME N509 and ASME N510 to older ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Arndt, T.E. [Westinghouse Hanford Company, Richland, WA (United States)

    1995-02-01

    This paper presents an example of a component replacement (electric heater) when installed in an older ventilation system that was constructed before the issuance of ASME N509{sup 1} and N510{sup 2}. Many of the existing ventilation systems at the Hanford Site were designed, fabricated, and installed before the issuance of ASME N509{sup 1} and N510{sup 2}. Requiring the application of these codes to existing ventilation systems presents challenges to the engineer when design changes are needed. Although it may seem that the application of ASME N509{sup 1} or N510{sup 2} may be a hindrance at times, this does not need to occur. Proper preparation at the start of project or design modifications can minimize frustration to the engineer when it is judged that portions of ASME N509{sup 1} and N510{sup 2} do not apply in a particular application.

  7. Operation technology of the ventilation system of the radioactive waste treatment facility(II) - Design and operation note

    Energy Technology Data Exchange (ETDEWEB)

    Lee, K. M.; Lee, B. C.; Bae, S. M. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-12-01

    As the radioactive waste treatment work, such as compaction and/or solidification of wastes, are done directly by the workers in the Radioactive Waste Treatment Facility, the reasonable design and operation of the ventilation system is essential. In this report, the design criteria and specification of the ventilation equipment, system operation method are described for the effective design and operation of ventilation system in the radioactive waste treatment facility. And the anti-vibration work which was done in the Radioactive Waste Treatment Facility in KAERI to reduce the effect of vibration due to the continuous operation of big rotational equipment, the intake fans and the exhaust fans, are described in the report. 11 refs., 10 figs., 12 tabs. (Author)

  8. Assessment of the Economic and Environmental Impact of Double Glazed Façade Ventilation Systems in Mediterranean Climates

    Directory of Open Access Journals (Sweden)

    Pere Alavedra

    2013-09-01

    Full Text Available Free convection is the most often used method in order to reduce solar load gains on a building with double glazed façades (DGFs. However, depending on the climate factors, the thermal performance of a DGF may not be satisfactory and extra energy costs are required to obtain suitable comfort conditions inside the building. Forced ventilation systems are a feasible alternative to improve the thermal performance of a DGF in Mediterranean climates where large solar gains are a permanent condition throughout the year. In this paper the feasibility of using diverse forced ventilation methods in DGF is evaluated. In addition, an economical comparison between different mechanical ventilation systems was performed in order to demonstrate the viability of DGF forced ventilation. Moreover, an environmental study was carried out to prove the positive energetic balance on cooling loads between free and forced convection in DGF for Mediterranean climates. For this investigation, a CFD model was used to simulate the thermal conditions in a DGF for the different ventilation systems. Results obtained for heat flux, temperature and reductions in solar load gains were analyzed and applied for the economic and environmental research.

  9. Experimental analysis of fuzzy controlled energy efficient demand controlled ventilation economizer cycle variable air volume air conditioning system

    Directory of Open Access Journals (Sweden)

    Rajagopalan Parameshwaran

    2008-01-01

    Full Text Available In the quest for energy conservative building design, there is now a great opportunity for a flexible and sophisticated air conditioning system capable of addressing better thermal comfort, indoor air quality, and energy efficiency, that are strongly desired. The variable refrigerant volume air conditioning system provides considerable energy savings, cost effectiveness and reduced space requirements. Applications of intelligent control like fuzzy logic controller, especially adapted to variable air volume air conditioning systems, have drawn more interest in recent years than classical control systems. An experimental analysis was performed to investigate the inherent operational characteristics of the combined variable refrigerant volume and variable air volume air conditioning systems under fixed ventilation, demand controlled ventilation, and combined demand controlled ventilation and economizer cycle techniques for two seasonal conditions. The test results of the variable refrigerant volume and variable air volume air conditioning system for each techniques are presented. The test results infer that the system controlled by fuzzy logic methodology and operated under the CO2 based mechanical ventilation scheme, effectively yields 37% and 56% per day of average energy-saving in summer and winter conditions, respectively. Based on the experimental results, the fuzzy based combined system can be considered to be an alternative energy efficient air conditioning scheme, having significant energy-saving potential compared to the conventional constant air volume air conditioning system.

  10. A study of energy use for ventilation and air-conditioning systems in Hong Kong

    Science.gov (United States)

    Yu, Chung Hoi Philip

    Most of the local modern buildings are high-rise with enclosed structure. Mechanical ventilation and air conditioning (MVAC) systems are installed for thermal comfort. Various types of MVAC systems found in Hong Kong were critically reviewed with comments on their characteristics in energy efficiency as well as application. The major design considerations were also discussed. Besides MVAC, other energy-consuming components in commercial buildings were also identified, such as lighting, lifts and escalators, office equipment, information technology facilities, etc. A practical approach has been adopted throughout this study in order that the end results will have pragmatic value to the heating, ventilating and air-conditioning (HVAC) industry in Hong Kong. Indoor Air Quality (IAQ) has become a major issue in commercial buildings worldwide including Hong Kong. Ventilation rate is no doubt a critical element in the design of HVAC systems, which can be realized more obviously in railway train compartments where the carbon dioxide level will be built up quickly when the compartments are crowded during rush hours. A study was carried out based on a simplified model using a train compartment that is equipped with an MVAC system. Overall Thermal Transfer Value (OTTV) is a single-value parameter for controlling building energy use and is relatively simple to implement legislatively. The local government has taken a first step in reacting to the worldwide concern of energy conservation and environmental protection since 1995. Different methods of OTTV calculation were studied and the computation results were compared. It gives a clear picture of the advantages and limitations for each method to the building designers. However, due to the limitations of using OTTV as the only parameter for building energy control, some new approaches to a total control of building energy use were discussed and they might be considered for future revision of the building energy codes in Hong

  11. Optimising ventilation-system design for a container-housed engine

    Energy Technology Data Exchange (ETDEWEB)

    Sala, J.M.; Eguia, J.; Flores, I. [Escuela Superior de Ingenieros Industriales de Bilbao, Universidad del Pais Vasco, Alameda de Urquijo, s/n 48013 Bilbao (Bizkaia) (Spain); Lopez-Gonzalez, L.M.; Ruiz de Adana, M. [Escuela Tecnica Superior de Ingenieria Industrial, Depto de Ingenieria Mecanica, Universidad de La Rioja, C/Luis de Ulloa, 20, E-26004 Logrono (La Rioja) (Spain); Miguez, J.L. [Universidad de Vigo, Escuela Tecnica Superior de Ingenieros Industriales, C/Lagoas-Marcosende, s/n 36200 Vigo (Pontevedra) (Spain)

    2006-10-15

    Containerised cogeneration sets, CCSs, are an efficient answer for remote developing regions which do not have alternative energy sources and for those applications requiring mobility and the quick installation of energy plants. Nevertheless, CCSs can present over-heating problems as a result of inefficient ventilation. The heat dissipated by each of the 28 elements under consideration in the engine compartment was assessed, together with the mass flow rate of air supplied to the cab and the air temperature at the inlet and outlet. A Computational Fluid Dynamics (CFD) model has been developed that allows for simulation of the parameters of velocity, temperature and pressure and for calculating the heat flows in a CCS with a reciprocating diesel engine, with an alternator power of 903kW. Predictions from this model have been contrasted with the experimental data obtained in a series of measurements. The CFD model has been used to analyse possible alternatives for improving the ventilation system. Besides the use of insulation to reduce the heat dissipated, other alternatives have been studied: e.g., improving the airflow by fitting a metal sheet as a deflector, or using a third fan. Of the three alternatives analysed, the company has decided to incorporate the simplest and cheapest, consisting in fitting a metal sheet around the alternator. (author)

  12. Comparison of two humidification systems for long-term noninvasive mechanical ventilation.

    Science.gov (United States)

    Nava, S; Cirio, S; Fanfulla, F; Carlucci, A; Navarra, A; Negri, A; Ceriana, P

    2008-08-01

    There is no consensus concerning the best system of humidification during long-term noninvasive mechanical ventilation (NIMV). In a technical pilot randomised crossover 12-month study, 16 patients with stable chronic hypercapnic respiratory failure received either heated humidification or heat and moisture exchanger. Compliance with long-term NIMV, airway symptoms, side-effects and number of severe acute pulmonary exacerbations requiring hospitalisation were recorded. Two patients died. Intention-to-treat statistical analysis was performed on 14 patients. No significant differences were observed in compliance with long-term NIMV, but 10 out of 14 patients decided to continue long-term NIMV with heated humidification at the end of the trial. The incidence of side-effects, except for dry throat (significantly more often present using heat and moisture exchanger), hospitalisations and pneumonia were not significantly different. In the present pilot study, the use heated humidification and heat and moisture exchanger showed similar tolerance and side-effects, but a higher number of patients decided to continue long-term noninvasive mechanical ventilation with heated humidification. Further larger studies are required in order to confirm these findings.

  13. KAERI underground research tunnel (KURT)

    International Nuclear Information System (INIS)

    Cho, Won Jin; Kwon, Sang Ki; Park, Jeong Hwa; Choi, Jong Won

    2007-01-01

    An underground research tunnel is essential to validate the integrity of a high-level waste disposal system, and the safety of geological disposal. In this study, KAERI underground research tunnel (KURT) was constructed in the site of Korea Atomic Energy Research Institute(KAERI). The results of the site investigation and the design of underground tunnel were presented. The procedure for the construction permits and the construction of KURT were described briefly. The in-situ experiments being carried out at KURT were also introduced

  14. Effect of a ceiling fan ventilation system on finishing young bulls' health, behaviour and growth performance.

    Science.gov (United States)

    Magrin, L; Brscic, M; Lora, I; Rumor, C; Tondello, L; Cozzi, G; Gottardo, F

    2017-06-01

    This research aimed at assessing the effects of a ceiling fan ventilation system on health, feeding, social behaviour and growth response of finishing young bulls fattened indoors during a mild summer season. A total of 69 Charolais young bulls were housed in six pens without any mechanical ventilation system (Control) and in six pens equipped with ceiling fans. The experimental period lasted 98 days from June until mid-September 2014. Four experimental days were considered in order to assess the effect of the ventilation system under two different microclimatic conditions: 2 alert days at monthly interval with temperature humidity index (THI) between 75 and 78, and 2 normal days with THI⩽74. Health and behaviour of the bulls were evaluated through 8-h observation sessions starting after morning feed delivery. The study was carried out during a rather cool summer with a climate average THI of 68.9 and 4 days with average THI>75. Despite these mild climate conditions, ceiling fans lowered litter moisture and acted as a preventive measure for bulls' dirtiness (odd ratio=47.9; 95% CI 19.6 to 117.4). The risk of abnormal breathing was increased for Control bulls (odd ratio=40.7; 95% CI 5.4 to 304.2). When exposed to alert THI conditions, respiration rate and panting scores increased and rumination duration dropped in Control bulls compared with bulls provided with a ceiling fan. During observations under alert THI, bulls spent less time eating, more time being inactive and consumed more water compared with normal THI conditions. Bulls' daily dry matter intake measured during the observation sessions decreased on alert compared with normal THI days (Pbehaviour (rumination, lying down and drinking water) and respiration rate, however. The lack of a significant improvement of bulls' growth response should not discourage beef farmers from using ceiling fans in indoor systems, considering the likely increase in frequency and intensity of heat waves in the planet

  15. A novel fuzzy logic inference system for decision support in weaning from mechanical ventilation.

    Science.gov (United States)

    Kilic, Yusuf Alper; Kilic, Ilke

    2010-12-01

    Weaning from mechanical ventilation represents one of the most challenging issues in management of critically ill patients. Currently used weaning predictors ignore many important dimensions of weaning outcome and have not been uniformly successful. A fuzzy logic inference system that uses nine variables, and five rule blocks within two layers, has been designed and implemented over mathematical simulations and random clinical scenarios, to compare its behavior and performance in predicting expert opinion with those for rapid shallow breathing index (RSBI), pressure time index and Jabour' weaning index. RSBI has failed to predict expert opinion in 52% of scenarios. Fuzzy logic inference system has shown the best discriminative power (ROC: 0.9288), and RSBI the worst (ROC: 0.6556) in predicting expert opinion. Fuzzy logic provides an approach which can handle multi-attribute decision making, and is a very powerful tool to overcome the weaknesses of currently used weaning predictors.

  16. VENTILATION MODEL

    International Nuclear Information System (INIS)

    V. Chipman

    2002-01-01

    The purpose of the Ventilation Model is to simulate the heat transfer processes in and around waste emplacement drifts during periods of forced ventilation. The model evaluates the effects of emplacement drift ventilation on the thermal conditions in the emplacement drifts and surrounding rock mass, and calculates the heat removal by ventilation as a measure of the viability of ventilation to delay the onset of peak repository temperature and reduce its magnitude. The heat removal by ventilation is temporally and spatially dependent, and is expressed as the fraction of heat carried away by the ventilation air compared to the fraction of heat produced by radionuclide decay. One minus the heat removal is called the wall heat fraction, or the remaining amount of heat that is transferred via conduction to the surrounding rock mass. Downstream models, such as the ''Multiscale Thermohydrologic Model'' (BSC 2001), use the wall heat fractions as outputted from the Ventilation Model to initialize their postclosure analyses

  17. Demand controlled ventilation; Behovsstyrt ventilasjon

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, Henning Holm

    2006-07-01

    The terms CAV and VAV have been known terms for many years in the ventilation business. The terms are also included in building regulations, but the time is now right to focus on demand controlled ventilation (DCV). The new building regulations and the accompanying energy framework underline the need for a more nuanced thinking when it comes to controlling ventilation systems. Descriptions and further details of the ventilation systems are provided (ml)

  18. Evaluation of a Mapleson D CPAP system for weaning of mechanical ventilation in pediatric patients

    Directory of Open Access Journals (Sweden)

    Miguel Angel Palomero-Rodríguez

    2016-01-01

    Full Text Available Background: Over the last years, we have used a flow-inflating bag circuit with a nasotracheal or nasopharyngeal tube as an interface to deliver effective CPAP support in infants (“Mapleson D CPAP system”. The primary goal of this study was to assess the usefulness of the “Mapleson D CPAP system” for weaning of mechanical ventilation (MV in infants who received MV over 24 h. Materials and Methods: All infants who received MV for more than 24 h in the last year were enrolled in the study. Demographic data included age, gender, weight, and admission diagnosis. Heart rate, respiratory rate, blood pressure, and oxygen saturation were measured during MV, 2 h after the nasotracheal Mapleson D CPAP system and 2 h after extubation. Patients were classified into two groups: patients MV more than 48 h, and patients with MV fewer than 48 h. P < 0.05 was considered statistically significant. Results: A total of 50 children were enrolled in the study, with a median age was 34 ± 45 months (range, 1-59 months and median weight was 11.98 ± 9.31 kg (range, 1-48 kg. Median duration of MV was 480 h (range, 2-570. There were no significant differences in PaO 2 , PaCO 2 , and pH among MV, 2 h after the nasotracheal Mapleson D CPAP system and 2 h after extubation and spontaneous ventilation with the nasopharyngeal Mapleson D CPAP system or with nasal prongs. The overall extubation failure rate was 26% (n = 13. Weight and age were significantly associated with extubation failure (P < 0.05. Conclusions: The Mapleson D CPAP system, in our opinion, is a useful and safe alternative to more complex and expensive noninvasive CPAP and BiPAP weaning from MV in infants.

  19. Evaluation of a Shaker Dust Collector for Use in a Recirculating Ventilation System.

    Science.gov (United States)

    Peters, Thomas M; Sawvel, Russell A; Park, Jae Hong; Anthony, T Renée

    2015-01-01

    General ventilation with recirculated air may be cost-effective to control the concentration of low-toxicity, contaminants in workplaces with diffuse, dusty operations, such as in agriculture. Such systems are, however, rarely adopted with little evidence showing improved air quality and ability to operate under harsh conditions. The goal of this work was to examine the initial and long-term performance of a fabric-filter shaker dust collector (SDC) in laboratory tests and as deployed within a recirculating ventilation system in an agricultural building. In laboratory tests, collection efficiency and pressure drop were tracked over several filter loading cycles, and the recovery of filter capacity (pressure drop) from filter shaking was examined. Collection efficiencies of particles larger than 5 μm was high (>95%) even when the filter was pristine, showing effective collection of large particles that dominate inhalable concentrations typical of agricultural dusts. For respirable-sized particles, collection efficiencies were low when the filter was pristine (e.g., 27% for 1 μm) but much higher when a dust cake developed on the filter (>99% for all size particles), even after shaking (e.g., 90% for 1 μm). The first shake of a filter was observed to recovery a substantial fraction of filter capacity, with subsequent shakes providing little benefit. In field tests, the SDC performed effectively over a period of three months in winter when incorporated in a recirculating ventilation system of a swine farrowing room. Trends in collection efficiency and pressure drop with loading were similar to those observed in the laboratory with overall collection efficiencies high (>80%) when pressure drop exceeded 230 Pa, or 23% of the maximum loading recommended by the manufacturer. This work shows that the SDC can function effectively over the harsh winter in swine rearing operations. Together with findings of improved air quality in the farrowing room reported in a

  20. Natural Ventilation in Atria

    DEFF Research Database (Denmark)

    Svidt, Kjeld; Heiselberg, Per; Hendriksen, Ole Juhl

    This case study comprises a monitoring programme as well as a Computational Fluid Dynamics (CFD) analysis of a natural ventilated atrium. The purpose has been to analyse the performance of a typical natural ventilation system in Denmark under both summer and winter conditions....

  1. The Canfranc Underground Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Amare, J. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Beltran, B. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Carmona, J.M. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Cebrian, S. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Garcia, E. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Irastorza, I.G. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Gomez, H. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Luzon, G. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Martinez, M. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Morales, J. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Ortiz de Solorzano, A. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Pobes, C. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Puimedon, J. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Rodriguez, A. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Ruz, J. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Sarsa, M.L. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Torres, L. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Villar, J.A. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain)

    2005-06-15

    This paper describes the forthcoming enlargement of the Canfranc Underground Laboratory (LSC) which will allow to host new international Astroparticle Physics experiments and therefore to broaden the European underground research area. The new Canfranc Underground Laboratory will operate in coordination (through the ILIAS Project) with the Gran Sasso (Italy), Modane (France) and Boulby (UK) underground laboratories.

  2. Design of Energy Efficient Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per

    The focus in the development has for both systems been to minimise energy consumption while maintaining a comfortable and healthy indoor environment. The natural next step in this development is to develop ventilation concepts that utilises and combines the best features from each system......[Mechanical and natural ventilation] into a new type of ventilation system- Hybrid Ventilation....

  3. Technical realization of a closure concept for a chamber-system in the underground Richard repository in the Czech Republic

    International Nuclear Information System (INIS)

    Kucerka, Miroslav

    2006-01-01

    The Phare project CZ 632.02.04 'Realization of closure of a chamber in the Richard repository as input for establishing a safety case' is a follow up implementation phase of the Phare project, CZ 01.14.03 'Solution for closure of a chamber in the Richard repository'. Main objective of both projects is to propose and realize a disposal system in selected chambers of the Richard repository, which will eliminate burden from the past practices in waste management during the first phase of the Richard repository operation (1965 - 1980) and which will improve its overall long term safety. This objective will be assured by realization of the concept of so called 'hydraulic cage', which technical solution was developed by DBE Technology within the Phare project CZ 01.14.03. The solution is described in the previous presentation 'Hydraulic Cage Concept for Waste Chambers and its Technical Implementation for the Underground Richard Repository, Litomerice, Czech Republic'. (author)

  4. Low-energy mechanical ventilation

    DEFF Research Database (Denmark)

    Andersen, Claus Wessel; Hviid, Christian Anker

    2014-01-01

    and with as little energy consumption as 41.1 kWh/m2/year including heating and all building services with no use of renewable energy such as PVcells or solar heating. One of the key means of reaching the objectives was to implement mechanical ventilation with low pressure loss and therefore low energy consumption....... The project consists of two buildings, building one is 6 stories high, and building two is 4 stories high. The buildings have a gross area of 50,500 m2 including underground parking. The ventilation and indoor climate concept was to use mechanical ventilation together with mechanical cooling and fanassisted......, with an average of 1.1 kJ/m3. The yearly mean SFP based on estimated runtime is approx. 0.8 kJ/m3. The case shows the unlocked potential that lies within mechanical ventilation for nearzero energy consuming buildings....

  5. Experimental Study of an Integrated System with Diffuse Ceiling Ventilation and Thermally Activated Building Constructions

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per

    of thermal comfort and energy performance. 20 cases with different boundary conditions are conducted varying on climate condition heat load. TABS water temperature and flow rate with or without diffuse ceiling. The energy evaluation includes energy balance of test room and cooling or heating capacity of TABS....... And the thermal comfort is analyzed by draught rate vertical temperature gradient and radiant temperature asymmetry. Finally the effect of plenum and diffuse ceiling is discussed. This report mainly focuses on the experiment results and discussions. Therefore, some details about the measurement are not presented......The experiments are carried out in a climate chamber located at the Department of Civil Engineering Aalborg University. The objective of the experiments is to evaluate the performance of the system combining diffuse ceiling ventilation and thermally activated building construction (TABS) in terms...

  6. New counter flow heat exchanger designed for ventilation systems in cold climates

    DEFF Research Database (Denmark)

    Kragh, Jesper; Rose, Jørgen; Nielsen, Toke Rammer

    2007-01-01

    In cold climates, mechanical ventilation systems with highly efficient heat recovery will experience problems with condensing water from the extracted humid indoor air. If the condensed water changes to ice in the heat exchanger, the airflow rate will quickly fall due to the increasing pressure...... of the developed beat exchanger are low pressure loss, cheap materials and a simple construction. The disadvantage is that the exchanger is big compared with other heat exchangers. In this paper, the new heat exchanger's efficiency is calculated theoretically and measured experimentally. The experiment shows...... drop. Preheating the inlet air (outdoor air) to a temperature above 0 degrees C before it enters the exchanger is one solution often used to solve the problem, however, this method reduces the energy saving potential significantly. To minimize the energy cost, a more efficient way to solve the freezing...

  7. Microclimate measuring and fluid‑dynamic simulation in an industrial broiler house: testing of an experimental ventilation system.

    Science.gov (United States)

    Bianchi, Biagio; Giametta, Ferruccio; La Fianza, Giovanna; Gentile, Andrea; Catalano, Pasquale

    2015-01-01

    The environment in the broiler house is a combination of physical and biological factors generating a complex dynamic system of interactions between birds, husbandry system, light, temperature, and the aerial environment. Ventilation plays a key role in this scenario. It is pivotal to remove carbon dioxide and water vapor from the air of the hen house. Adequate ventilation rates provide the most effective method of controlling temperature within the hen house. They allow for controlling the relative humidity and can play a key role in alleviating the negative effects of high stocking density and of wet litter. In the present study the results of experimental tests performed in a breeding broiler farm are shown. In particular the efficiency of a semi transversal ventilation system was studied against the use of a pure transversal one. In order to verify the efficiency of the systems, fluid dynamic simulations were carried out using the software Comsol multiphysics. The results of this study show that a correct architectural and structural design of the building must be supported by a design of the ventilation system able to maintain the environmental parameters within the limits of the thermo‑neutral and welfare conditions and to achieve the highest levels of productivity.

  8. Physiologic effects of an ambulatory ventilation system in chronic obstructive pulmonary disease.

    Science.gov (United States)

    Porszasz, Janos; Cao, Robert; Morishige, Richard; van Eykern, Leo A; Stenzler, Alex; Casaburi, Richard

    2013-08-01

    Exercise intolerance limits the ability of patients with chronic obstructive pulmonary disease (COPD) to perform daily living activities. Noninvasive ventilation reduces dyspnea and improves exercise performance, but current systems are unsuitable for ambulatory use. In patients with COPD experiencing exercise-induced desaturation, we evaluated improvements in exercise tolerance facilitated by a wearable, 1-lb, noninvasive open ventilation (NIOV) system featuring a nasal pillow interface during constant work rate (CWR) cycle ergometer exercise and associated effects on dyspnea, respiratory muscle activation, and pulmonary gas exchange efficiency. Fifteen men with COPD (FEV₁ = 32.2 ± 12.0% predicted; FEV₁/FVC = 31.6 ± 7.1%; exercise oxygen saturation as measured by pulse oximetry [Spo₂] = 86.5 ± 2.9%) participated. After incremental testing establishing peak work rate, subjects completed three visits in which they performed CWR exercise to tolerance at 80% peak work rate: (1) unencumbered breathing room air, (2) using NIOV+compressed air, (3) using NIOV+compressed O₂, or (4) using O₂ via nasal cannula. Assessments included exercise duration, surface inspiratory muscle EMG, Spo₂, transcutaneous Pco₂, and Borg dyspnea scores. Exercise endurance was 17.6 ± 5.7 minutes using NIOV+O₂, greatly prolonged compared with unencumbered (5.6 ± 1.9 min), nasal O₂ (11.4 ± 6.8 min), and NIOV+Air (6.3 ± 4.1 min). Isotime Spo₂ was higher and intercostal, scalene, and diaphragmatic EMG activity was reduced using NIOV+O₂ compared with unencumbered, nasal O₂, and NIOV+Air, signifying respiratory muscle unloading. Isotime dyspnea reduction correlated with isotime EMG reduction (r = 0.42, P = 0.0053). There were no significant differences in isotime VD/VT or transcutaneous Pco₂ among treatments. NIOV+O₂ yielded substantial exercise endurance improvements accompanied by respiratory muscle unloading and dyspnea reductions in patients with severe hypoxemic

  9. Impact of ventilation systems and energy savings in a building on the mechanisms governing the indoor radon activity concentration.

    Science.gov (United States)

    Collignan, Bernard; Powaga, Emilie

    2017-11-23

    For a given radon potential in the ground and a given building, the parameters affecting the indoor radon activity concentration (IRnAC) are indoor depressurization of a building and its air change rate. These parameters depend mainly on the building characteristics, such as airtightness, and on the nature and performances of the ventilation system. This study involves a numerical sensitivity assessment of the indoor environmental conditions on the IRnAC in buildings. A numerical ventilation model has been adapted to take into account the effects of variations in the indoor environmental conditions (depressurization and air change rate) on the radon entry rate and on the IRnAC. In the context of the development of a policy to reduce energy consumption in a building, the results obtained showed that IRnAC could be strongly affected by variations in the air permeability of the building associated with the ventilation regime. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Building a Comprehensive System of Services to Support Adults Living with Long-Term Mechanical Ventilation

    Directory of Open Access Journals (Sweden)

    David Leasa

    2016-01-01

    Full Text Available Background. Increasing numbers of individuals require long-term mechanical ventilation (LTMV in the community. In the South West Local Health Integration Network (LHIN in Ontario, multiple organizations have come together to design, build, and operate a system to serve adults living with LTMV. Objective. The goal was to develop an integrated approach to meet the health and supportive care needs of adults living with LTMV. Methods. The project was undertaken in three phases: System Design, Implementation Planning, and Implementation. Results. There are both qualitative and quantitative evidences that a multiorganizational system of care is now operational and functioning in a way that previously did not exist. An Oversight Committee and an Operations Management Committee currently support the system of services. A Memorandum of Understanding has been signed by the participating organizations. There is case-based evidence that hospital admissions are being avoided, transitions in care are being thoughtfully planned and executed collaboratively among service providers, and new roles and responsibilities are being accepted within the overall system of care. Conclusion. Addressing the complex and variable needs of adults living with LTMV requires a systems response involving the full continuum of care.

  11. Ventilation of nuclear power plants

    International Nuclear Information System (INIS)

    Madoyan, A.A.; Vlasik, V.F.

    1984-01-01

    Foundations and calculation methods of ventilation of rooms with different degree of heat and gas release with the change of operation mode of NPP main equipment, as well as problems of NPP site and adjoining area aerodynamics, have been presented. Systems of air ventilation and conditioning, cooling equipment, are considered. The main points of designing are described and determination of economic efficiency of the ventilation systems are made. Technical characteristics of the ventilators, conditioners, filters and air heaters used, are presented. Organization of adjustment, tests, operation and maintenance of the ventilation systems of NPP with RBMK and WWER-type reactors, is described

  12. Evaluation of waste temperatures in AWF tanks for bypass mode operation of the 702-AZ ventilation system (Project W-030)

    International Nuclear Information System (INIS)

    Sathyanarayana, K.

    1997-01-01

    This report describes the results of thermal hydraulic analysis performed to provide data in support of Project W-030 to startup new 702-AZ Primary Ventilation System. During the startup of W-030 system, the ventilation system will be operating in bypass mode. In bypass made of operation, the system is capable of supplying 1000 cfm total flow for all four AWF doubleshell tanks. The design of the W-030 system is based on the assumption that both the recirculation loop of the primary ventilation system and the secondary ventilation which provides cooling would be operating. However, during the startup neither the recirculation system nor the secondary ventilation system will be operating. A minimum flow of 100 cfm is required to prevent any flammable gas associated risk. The remaining 600 cfm flow can be divided among the four tanks as necessary to keep the peak sludge temperatures below the operating temperature limit. For the purpose of determining the minimum flow required for cooling each tank, the thermal hydraulic analysis is performed to predict the peak sludge temperatures in AY/AZ tanks under different ventilation flows. The heat load for AZ farm tanks is taken from characterization reports and for the AY farm tanks, the heat load was estimated by thermal analysis using the measured waste temperatures and the waste liquid evaporation rates. The tank 241-AZ-101 and the tank 241-AZ-102 have heat loads of 241,600 and 199,500 Btu/hr respectively. The tank 241-AY-101 and tank 241-AY-102 have heat loads of 41,000 and 33,000 Btu/hr respectively. Using the ambient meteorological conditions of temperature and relative humidity for the air and tank, some soil surface and the sludge levels reported in recent documents, the peak sludge and supernatant temperatures were predicted for various primary ventilation flows ranging from 100 to 400 cfm for AZ tanks and 100 and 150 cfm for AY tanks. The results of these thermal hydraulic analyses are presented. Based on the

  13. Optimal Design of Cogeneration Systems in Industrial Plants Combined with District Heating/Cooling and Underground Thermal Energy Storage

    Directory of Open Access Journals (Sweden)

    Vincenzo Dovì

    2011-12-01

    Full Text Available Combined heat and power (CHP systems in both power stations and large plants are becoming one of the most important tools for reducing energy requirements and consequently the overall carbon footprint of fundamental industrial activities. While power stations employ topping cycles where the heat rejected from the cycle is supplied to domestic and industrial consumers, the plants that produce surplus heat can utilise bottoming cycles to generate electrical power. Traditionally the waste heat available at high temperatures was used to generate electrical power, whereas energy at lower temperatures was either released to the environment or used for commercial or domestic heating. However the introduction of new engines, such as the ones using the organic Rankine cycle, capable of employing condensing temperatures very close to the ambient temperature, has made the generation of electrical power at low temperatures also convenient. On the other hand, district heating is becoming more and more significant since it has been extended to include cooling in the warm months and underground storage of thermal energy to cope with variable demand. These developments imply that electric power generation and district heating/cooling may become alternative and not complementary solutions for waste energy of industrial plants. Therefore the overall energy management requires the introduction of an optimisation algorithm to select the best strategy. In this paper we propose an algorithm for the minimisation of a suitable cost function, for any given variable heat demand from commercial and domestic users, with respect to all independent variables, i.e., temperatures and flowrates of warm fluid streams leaving the plants and volume and nature of underground storage. The results of the preliminary process integration analysis based on pinch technology are used in this algorithm to provide bounds on the values of temperatures.

  14. Demand control on room level of the supply air temperature in an air heating and ventilation system

    DEFF Research Database (Denmark)

    Polak, Joanna; Afshari, Alireza; Bergsøe, Niels Christian

    2017-01-01

    The aim of this study was to investigate a new strategy for control of supply air temperature in an integrated air heating and ventilation system. The new strategy enables demand control of supply air temperature in individual rooms. The study is based on detailed dynamic simulations of a combined...

  15. JACoW Virtual control commissioning for a large critical ventilation system: The CMS cavern use case

    CERN Document Server

    Booth, William; Bradu, Benjamin; Sourisseau, Samuel

    2018-01-01

    The current cavern ventilation control system of the CMS experiment at CERN is based on components which are already obsolete: the SCADA system, or close to the end of life: the PLCs. The control system is going to be upgraded during the LHC Long Shutdown 2 (2019-2020) and will be based on the CERN industrial control standard: UNICOS employing WinCC OA as SCADA and Schneider PLCs. Due to the critical nature of the CMS ventilation installation and the short allowed downtime, the approach was to design an environment based on the virtual commissioning of the new control. This solution uses a first principles model of the ventilation system to simulate the real process. The model was developed with the modelling and simulation software EcosimPro. In addition, the current control application of the cavern ventilation will also be re-engineered as it is not completely satisfactory in some transients where many sequences are performed manually and some pressure fluctuations observed could potentially cause issues t...

  16. Experimental study on the dynamic performance of a novel system combining natural ventilation with diffuse ceiling inlet and TABS

    DEFF Research Database (Denmark)

    Yu, Tao; Heiselberg, Per Kvols; Lei, Bo

    2016-01-01

    Highlights • Dynamic experiments are performed to study energy performance of a new HVAC system. • Designed control strategies show good utilization of natural ventilation cooling. • TABS work well with the diffuse ceiling in the dynamic measurements. • No local thermal comfort problem is found...

  17. Ontology for Life-Cycle Modeling of Heating, Ventilating, and Air Conditioning (HVAC) Systems: Experimental Applications Using Revit

    Science.gov (United States)

    2012-03-01

    Center, Construction Engineering Research Laboratory (ERDC-CERL) has developed a core life- cycle building information model ( BIM ) based on three...was to promote consistency and quality of content created for Building Information Models ( BIMs ) across various disciplines. The HVAC MVD was...MVD. 15. SUBJECT TERMS building information modeling ( BIM ), ontology, Army facilities, heating, ventilating, and air-conditioning (HVAC) systems

  18. An improved mathematical model for prediction of air quantity to minimise radiation levels in underground uranium mines.

    Science.gov (United States)

    Panigrahi, Durga Charan; Sahu, Patitapaban; Mishra, Devi Prasad

    2015-02-01

    Ventilation is the primary means of controlling radon and its daughter concentrations in an underground uranium mine environment. Therefore, prediction of air quantity is the vital component for planning and designing of ventilation systems to minimise the radiation exposure of miners in underground uranium mines. This paper comprehensively describes the derivation and verification of an improved mathematical model for prediction of air quantity, based on the growth of radon daughters in terms of potential alpha energy concentration (PAEC), to reduce the radiation levels in uranium mines. The model also explains the prediction of air quantity depending upon the quality of intake air to the stopes. This model can be used to evaluate the contribution of different sources to radon concentration in mine atmosphere based on the measurements of radon emanation and exhalation. Moreover, a mathematical relationship has been established for quick prediction of air quantity to achieve the desired radon daughter concentration in the mines. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Experimental Investigation of Convective Heat Transfer during Night Cooling with Different Ventilation Systems and Surface Emissivities

    DEFF Research Database (Denmark)

    Le Dreau, Jerome; Heiselberg, Per; Jensen, Rasmus Lund

    2013-01-01

    Night-time ventilation is a promising approach to reduce the energy needed for cooling buildings without reducing thermal comfort. Nevertheless actual building simulation tools have showed their limits in predicting accurately the efficiency of night-time ventilation, mainly due to inappropriate...

  20. Continuous monitoring of natural ventilation pressure at the Waste Isolation Pilot Plant

    International Nuclear Information System (INIS)

    Loomis, I.M.; Wallace, K.G.

    1993-01-01

    The Waste Isolation Pilot Plant (WIPP) is a US Department of Energy research and development facility designed to demonstrate the permanent, safe disposal of US defense-generated transuranic waste. The waste storage horizon is 655 m (2150 ft) below surface in bedded salt. To date the WIPP project has not emplaced any waste. There are three intake shafts used to supply air to the underground. All air is exhausted through a single return shaft. The total design airflow during normal operations is 200 m 3 /s (424,000 cfm). The ventilation system is designed to provide separate air splits to construction, experimental, and storage activities. Separation is achieved by isolating the storage circuit from the construction or experimental circuits with bulkheads. Any air leakage must be towards the storage area of the facility. Field studies have shown that the pressure differential necessary to maintain the correct leakage direction is susceptible to the effects of natural ventilation; therefore, extensive studies and analyses have been conducted to quantify the natural ventilation effects on the WIPP underground airflow system. A component of this work is a monitoring system designed to measure the air properties necessary for calculation of the natural ventilation pressure (NVP). This monitoring system consists of measuring dry bulb temperature, relative humidity, and barometric pressure at strategic location on surface and underground. The psychometric parameters of the air are measured every fifteen minutes. From these data, trends can be determined showing the impact of NVP on the ventilation system during diurnal variations in surface climate. Both summer and winter conditions have been studied. To the author's knowledge this is the first reported instance of automatic and continuous production of time and temperature variant NVPs. This paper describes the results of the initial monitoring study