WorldWideScience

Sample records for underground electric substations

  1. 30 CFR 57.4160 - Underground electric substations and liquid storage facilities.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground electric substations and liquid... Underground electric substations and liquid storage facilities. The requirements of this standard apply to...) Electric substations. (2) Unburied, combustible liquid storage tanks. (3) Any group of containers used for...

  2. Electric Substations

    Data.gov (United States)

    Department of Homeland Security — Substations. Substations are facilities and equipment that switch, transform, or regulate electric voltage. The Substations feature class includes taps, a location...

  3. Electric power substations engineering

    CERN Document Server

    McDonald, John D

    2012-01-01

    The use of electric power substations in generation, transmission, and distribution remains one of the most challenging and exciting areas of electric power engineering. Recent technological developments have had a tremendous impact on all aspects of substation design and operation. With 80% of its chapters completely revised and two brand-new chapters on energy storage and Smart Grids, Electric Power Substations Engineering, Third Edition provides an extensive updated overview of substations, serving as a reference and guide for both industry and academia. Contributors have written each chapt

  4. Using Immersive Virtual Reality for Electrical Substation Training

    Science.gov (United States)

    Tanaka, Eduardo H.; Paludo, Juliana A.; Cordeiro, Carlúcio S.; Domingues, Leonardo R.; Gadbem, Edgar V.; Euflausino, Adriana

    2015-01-01

    Usually, distribution electricians are called upon to solve technical problems found in electrical substations. In this project, we apply problem-based learning to a training program for electricians, with the help of a virtual reality environment that simulates a real substation. Using this virtual substation, users may safely practice maneuvers…

  5. Interference with the pacemakers of two workers at electricity substations.

    Science.gov (United States)

    Butrous, G S; Bexton, R S; Barton, D G; Male, J C; Camm, A J

    1983-11-01

    Pacemaker function was tested in two electricity substation workers exposed to high tension electric fields. High intensity electric fields induced reversion to the interference mode, producing in one case competitive rhythm and in the other inappropriately slow pacing which resulted in asymptomatic pauses of up to 2.5 s. A suit designed to shield the body from the effects of high intensity electric fields was tried and proved to be effective in protecting the pacemaker, allowing it to function normally in the substations.

  6. MONITORING OF ELECTRICAL ENERGY QUALITY ON THE TRACTION SUBSTATION INPUT

    Directory of Open Access Journals (Sweden)

    O.G. Gryb

    2015-12-01

    Full Text Available For the implementation of measures to maintain the quality of the energy industrial enterprises have to spend a significant material and monetary assets. In this regard, significant is the feasibility study of the allocation of such funds and, primarily, the determination of the economic damage arising from low quality of electricity. The reliability of the electricity metering system, relay protection and automation of modern digital substations depends on the quality of electrical energy. At the present time to improve the reliability of the substation operation it is necessary to monitor indicators of quality of electric energy, allowing you to take organizational and technical solutions for their improvement. Monitoring the power quality at the input traction substation has shown that indicators such as the coefficient of the n-th harmonic component of the voltage does not meet the standards GOST 13109-97. The source of higher harmonics is a voltage Converter used on the locomotive. To eliminate higher harmonics in the supply network for traction substations will need to install power filters. Today, the USB-analyzer of power quality «Digital measurement system of power quality» type of CSICE of accuracy class 0.2. Work energy requires reliable and quality electricity supply to consumers. The new model of balancing energy market are bilateral contracts. The main task of this market, it ensure the stable and reliable operation of the unified energy system of Ukraine, that is, transmission and supply of electricity of appropriate quality.

  7. 30 CFR 56.4130 - Electric substations and liquid storage facilities.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric substations and liquid storage... MINES Fire Prevention and Control Prohibitions/precautions/housekeeping § 56.4130 Electric substations... shall be stored or allowed to accumulate within 25 feet of the following: (1) Electric substations. (2...

  8. Monitoring of electrical energy quality on the traction substation input

    OpenAIRE

    Gryb, O. G.; Gapon, D. A.; Ierusalimova, T. S.; Borodin, D. V.

    2015-01-01

    For the implementation of measures to maintain the quality of the energy industrial enterprises have to spend a significant material and monetary assets. In this regard, significant is the feasibility study of the allocation of such funds and, primarily, the determination of the economic damage arising from low quality of electricity. The reliability of the electricity metering system, relay protection and automation of modern digital substations depends on the quality of electrical energy. A...

  9. Automatic Object Extraction from Electrical Substation Point Clouds

    Directory of Open Access Journals (Sweden)

    Mostafa Arastounia

    2015-11-01

    Full Text Available The reliability of power delivery can be profoundly improved by preventing wildlife-related power outages. This can be achieved by insulating electrical substation components with non-conductive covers. The manufacture of custom-built covers requires as-built models of the salient components. This study presents new, automated methodology to recognize key components of electrical substations from 3D LiDAR data acquired using terrestrial laser scanning. The proposed methodology includes six novel algorithms to recognize key components (fence, cables, circuit breakers, bushings and bus pipes of electrical substations. Three datasets with different resolutions and configurations are used in this study. A Leica HDS 6100 laser scanner was used to acquire the first dataset and a Faro Focus3D laser scanner was employed to collect the second and third datasets. The obtained results indicate that 178 and 171 out of 181 electrical substation elements were successfully recognized in the first and second dataset, respectively, and 183 out of 191 components were identified in the third dataset. The results also demonstrate that an average 97.8% accuracy and average 98.8% precision at the point cloud level can be achieved.

  10. 30 CFR 57.4130 - Surface electric substations and liquid storage facilities.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Surface electric substations and liquid storage... substations and liquid storage facilities. The requirements of this standard apply to surface areas only. (a... accumulate within 25 feet of the following: (1) Electric substations. (2) Unburied, flammable or combustible...

  11. Static Electricity as Part of Electromagnetic Environment on High-Voltage Electrical Substation

    Directory of Open Access Journals (Sweden)

    M. I. Fursanov

    2012-01-01

    Full Text Available Causes of occurrences electrostatic discharges (ESD on high-voltage electric substation were investigated and dependences values ESD’s on parameters interaction structures, humidity of air were found. Experimental research values ESD’s on high-voltage electric substation and in man-made conditions was fulfilled. Uncertainty measurement’s was taken into consideration by research results analyze. Matching with research of other authors was made. Danger ESD’s for electric devises was established.

  12. VT Electric Transmission Line Corridors - substation points

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) The ELTRN layer depicts electric transmission line corridors in Vermont. Various methods have been used to digitize features. The data layer...

  13. ENEL high and medium voltage electrical substations for power supply to urban centers

    International Nuclear Information System (INIS)

    Bargigia, A.; Boatto, C.; Di Mario, A.; Fava, N.; Sciarra, S.; Speziali, R.

    1991-12-01

    Modular high and medium voltage gas insulated electrical substations are being used by ENEL (Italian Electricity Board) to meet the specific needs of urban centers with special design and sizing constraints of a historical/architectural nature. This paper illustrates the key design, construction operation and performance characteristics of these standardized units. The descriptions include brief notes on equipment-transformer interconnection, interchangeability and environmental compatibility. Performance test procedures and results of actual reliability and certification tests on some substations are reported

  14. The fuzzy comprehensive evaluation on occupational health hazards of electric field in substation

    Science.gov (United States)

    Zhao, Xin; Wang, Jing; Gao, Yang; Chen, Tao

    2017-05-01

    In this paper, multilevel fuzzy analysis method is used to making a comprehensive evaluation on the health hazards of workers exposed to electric field in 500kV substation. The five different regions of 500kV substation is identified as the first level index, according to the specific measurement substation of each area to set up the second level index. The first level weight is established according to the proportion of the retention time of the workers in the different areas, and the weight of the second level is determined according to the proportion of the measuring points. Establishing five comment sets, and carrying out the fuzzy comprehensive evaluation according to the maximum membership principle, eventually come to the conclusion: although the measured data show that a small number of electric field intensity exposure value of 500kV substation beyond the requirements of the International Commission on non-ionizing radiation protection (ICNIRP) and the requirements of the People's Republic of China(PRC), but workers have very little contact time, therefore, it cannot be explained that there is a large occupational health hazard in 500kV substation. The multilevel fuzzy analysis method can be used to evaluate the health hazards of the electric field in the substation working environment well, it avoids the subjective and limitations of the traditional methods, and can be able to make a more accurate and objective judgment of the substation

  15. Measuring Occupational Exposure to Extremely Low-Frequency Electric Fields at 220 kV Substations.

    Science.gov (United States)

    Pirkkalainen, Herkko; Heiskanen, Timo; Tonteri, Juhani; Elovaara, Jarmo; Mika, Penttilä; Korpinen, Leena

    2017-11-01

    Earlier studies conducted at 400 and 110 kV substations in Finland have shown that the occupational exposure to electric fields can exceed the action levels (ALs) set by Directive 2013/35/EU. This is a case study investigating the level of occupational exposure experienced by workers at 220 kV substations in order to determine if the actions levels are being exceeded. The measurements were conducted at two old 220 kV substations in Finland. The higher AL of 20 kV m-1 was exceeded at both substations. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Characteristic Analysis of DC Electric Railway Systems with Superconducting Power Cables Connecting Power Substations

    Science.gov (United States)

    Ohsaki, H.; Matsushita, N.; Koseki, T.; Tomita, M.

    2014-05-01

    The application of superconducting power cables to DC electric railway systems has been studied. It could leads to an effective use of regenerative brake, improved energy efficiency, effective load sharing among the substations, etc. In this study, an electric circuit model of a DC feeding system is built and numerical simulation is carried out using MATLAB-Simulink software. A modified electric circuit model with an AC power grid connection taken into account is also created to simulate the influence of the grid connection. The analyses have proved that a certain amount of energy can be conserved by introducing superconducting cables, and that electric load distribution and concentration among the substations depend on the substation output voltage distribution.

  17. Electric and magnetic field testing in vicinity of 110/x kV substations

    Directory of Open Access Journals (Sweden)

    Grbić Maja

    2016-01-01

    Full Text Available The levels of non-ionizing radiation (electric and magnetic fields at power frequency, which occur near 110/x kV substations are analyzed in this paper. The results of electric field strength and magnetic flux density measurements in the vicinity of three typical substations of the aforementioned voltage level are shown. With the purpose of estimating the exposure of the population to these fields, the obtained results were compared to the reference maximum levels set for increased sensitivity areas, which amount to 2 kV/m for electric field and 40 μT for magnetic flux density. The objective of the conducted analysis is to reach general conclusions on the levels of electric and magnetic fields, which may occur in the vicinity of the substations mentioned above, and evaluate their compliance with the national regulations on the population protection from non-ionizing radiation.

  18. Determination of exposure to electric fields in extra high voltage substations.

    Science.gov (United States)

    Lövstrand, K G

    1976-09-01

    Electrophysical effects related to extra high voltage are surveyed for the determination of the exposure of personnel to electric fields in substations. It is concluded that the electric field strengths and the electrical discharges to the personnel are the important electrophysical factors. Instruments for measuring the field strength at grounded surfaces and at nonzero potentials were constructed. Results are presented of measurements with these instruments in substations. A dummy was used for the measurement of the distribution of capacitive currents to a man. The dummy can also be used for measuring the effectiveness of special shielding clothes.

  19. Procedures and criteria for increasing the earthquake resistance level of electrical substations and special installations

    Energy Technology Data Exchange (ETDEWEB)

    Couch, R.W.; Deacon, R.J.

    1973-09-30

    This report defines a procedure and provides basic information needed to determine the modifications required to make electrical substations and special installations of the Bonneville Power Administration (BPA) more resistant to strong earthquake ground motion. It also provides a procedure for developing an effective plan for establishing the sequence, or priority, of providing the required modifications.

  20. [Risk of electromagnetic fields in electric power stations and substations of a petrochemical plant].

    Science.gov (United States)

    Castagnoli, A; Fabri, G; Romeo, A

    2003-01-01

    Authors evaluate electromagnetic field exposure in the low-frequency range (5-30,000 Hz) in electric power stations and substations of petroleum processing plant. According to the measured values and the reference exposure limits considered, they conclude that operators should be exposed without adverse effects.

  1. Noise impact caused by electrical energy substations in the city of Curitiba, Brazil.

    Science.gov (United States)

    Diniz, F B; Zannin, P H T

    2004-07-26

    This survey is intended to characterize the noise impact due to electrical energy substations in the city of Curitiba over the population living in their vicinity. This impact has been studied with the aid of a computational tool capable of mapping the acoustical field of substations and their vicinity. Several factors have been considered in this survey: (1) sound power of the transformers; (2) vehicle flow on the surrounding roads; (3) positioning of the firewalls, buildings and walls; and (4) terrain topography. Four substations have been analyzed, and an acoustical map has been traced for each of them. With these maps it was possible to visualize what was the incident noise level on the building facades. The predicted noise levels have been compared to the environmental legislation of the noise emissions in effect in the city. Copyright 2004 Elsevier B.V.

  2. Electric Substations, Electric substation locations provided to us from Kansas City Power and Light and City of Gardner only at this time. AIMS is working on getting other providers in area. Data is limited to CUE (Collaborative Utility Exchange) Participants and subcontracto, Published in 2004, Johnson County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Electric Substations dataset current as of 2004. Electric substation locations provided to us from Kansas City Power and Light and City of Gardner only at this time....

  3. Energy saving in the operation of industrial electrical substations. Part I. Studies

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Jimenez, Juan J; Zerquera Izquierdo, Mariano D; Beltran Leon, Jose S; Garcia Martinez, Juan M; Alvarez Urena, Maria V; Meza Diaz, Guillermo [Universidad de Guadalajara (Mexico)]. E-mails: cheosj@yahoo.com; mdzi@hotmail.com; beltran5601@yahoo.com.mx; jmargarmtz@yahoo.com; victory_alvarez@telmexmail.com; depmec@cucei.udg.mx

    2013-03-15

    The main objective of this work is to offer a methodology for the operation of substations composed by two or more transformers that feed loads of first category. Understand by loads of first category those in that the interruption of the electric supply may cause the loss of human life. The core of this operation shows that in substations with several transformers, the number of transformers connected at a given moment should be one that avoids losses. [Spanish] El objetivo principal de este trabajo es ofrecer una metodologia para la operacion de subestaciones compuestas por dos o mas transformadores que alimentan cargas de primera categoria. Entendiendose por cargas de primera categoria, aquellas en que la interrupcion del suministro electrico puede causar la perdida de vidas humanas. El nucleo de esta operacion muestra que en las subestaciones con varios transformadores, el numero de transformadores conectados, en un momento dado, debe ser aquel que evite perdidas.

  4. Type B investigation of electrical fault in 351 Substation, December 4, 1994

    International Nuclear Information System (INIS)

    Debban, H.L.; Shearer, C.A.; Boger, R.M.; McDonald, G.P.; Eyre, L.E.; Dell, L.D.; Kelly, D.S.

    1995-02-01

    On December 4, 1994, at 2132:10 hours, an electrical failure of a cable-tapping splice resulted in a fire in the 300 Area of the DOE Hanford Site. The fire occurred in the yard of Substation 351 in electrical Vault R122V, where the cable-tapping splice was located. The fire incinerated all cables passing to and through the vault causing them to fail. The failure of the cables resulted in a power outage to twenty customers in the 300 Area. The vault was electrically isolated, and power was restored to the electrical distribution system at 2311 hours. This report contains the accident scenario, accident analysis, direct cause and root and contributing causes

  5. Type B investigation of electrical fault in 351 Substation, December 4, 1994

    Energy Technology Data Exchange (ETDEWEB)

    Debban, H.L.; Shearer, C.A.; Boger, R.M.; McDonald, G.P. [ICF Kaiser Hanford Co., Richland, WA (United States); Eyre, L.E.; Dell, L.D.; Kelly, D.S. [Westinghouse Hanford Co., Richland, WA (United States)

    1995-02-01

    On December 4, 1994, at 2132:10 hours, an electrical failure of a cable-tapping splice resulted in a fire in the 300 Area of the DOE Hanford Site. The fire occurred in the yard of Substation 351 in electrical Vault R122V, where the cable-tapping splice was located. The fire incinerated all cables passing to and through the vault causing them to fail. The failure of the cables resulted in a power outage to twenty customers in the 300 Area. The vault was electrically isolated, and power was restored to the electrical distribution system at 2311 hours. This report contains the accident scenario, accident analysis, direct cause and root and contributing causes.

  6. Occupational exposure to electric fields and currents associated with 110 kV substation tasks.

    Science.gov (United States)

    Korpinen, Leena H; Kuisti, Harri A; Tarao, Hiroo; Elovaara, Jarmo A

    2012-07-01

    The main aim of this study was to investigate occupational exposure to electric fields, and current densities and contact currents associated with tasks at air-insulated 110 kV substations and analyze if the action value of EU Directive 2004/40/EC was exceeded. Four workers volunteered to simulate the following tasks: Task (A) maintenance of an operating device of a disconnector at ground or floor level, Task (B) maintenance of an operating device of a circuit breaker at ground or floor level, Task (C) breaker head maintenance from a man hoist, and Task (D) maintenance of an operating device of a circuit breaker from a service platform. The highest maximum average current density in the neck was 1.8 mA/m(2) (calculated internal electric field 9.0-18.0 mV/m) and the highest contact current was 79.4 µA. All measured values at substations were lower than the limit value (10 mA/m(2)) of the EU Directive 2004/40/EC and the 2010 basic restrictions (0.1 and 0.8 V/m for central nervous system tissues of the head, and all tissues of the head and body, respectively) of the International Commission on Non-Ionizing Radiation Protection (ICNIRP). Copyright © 2012 Wiley Periodicals, Inc.

  7. Final environmental assessment for vegetation control at VHF stations, microwave stations, electrical substations, and pole yards

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-13

    Southwestern Power Adm. operates very high frequency (VHF) and microwave radio stations, electrical substations, and pole yards for electric power transmission throughout AR, MO, and OK. Vegetation growth at the stations must be suppressed for safety of operation and personnel. Southwestern has been using a combination of mechanical/manual and herbicide control for this purpose; Federally- mandated reductions in staff and budgetary resources require Southwestern to evaluate all potentially efficient methods for vegetation control. Three alternatives were examined: no action, mechanical/manual control, and (proposed) a combination of mechanical/manual and herbicide control. Environmental impacts on air and water quality, wetlands, wildlife, endangered species, archaeological and other resources, farmland, human health, transportation, etc. were evaluated.

  8. Multidimensional Risk Management for Underground Electricity Networks

    Directory of Open Access Journals (Sweden)

    Garcez Thalles V.

    2014-08-01

    Full Text Available In the paper we consider an electricity provider company that makes decision on allocating resources on electric network maintenance. The investments decrease malfunction rate of network nodes. An accidental event (explosion, fire, etc. or a malfunctioning on underground system can have various consequences and in different perspectives, such as deaths and injuries of pedestrians, fires in nearby locations, disturbances in the flow of vehicular traffic, loss to the company image, operating and financial losses, etc. For this reason it is necessary to apply an approach of the risk management that considers the multidimensional view of the consequences. Furthermore an analysis of decision making should consider network dependencies between the nodes of the electricity distribution system. In the paper we propose the use of the simulation to assess the network effects (such as the increase of the probability of other accidental event and the occurrence of blackouts of the dependent nodes in the multidimensional risk assessment in electricity grid. The analyzed effects include node overloading due to malfunction of adjacent nodes and blackouts that take place where there is temporarily no path in the grid between the power plant and a node. The simulation results show that network effects have crucial role for decisions in the network maintenance – outcomes of decisions to repair a particular node in the network can have significant influence on performance of other nodes. However, those dependencies are non-linear. The effects of network connectivity (number of connections between nodes on its multidimensional performance assessment depend heavily on the overloading effect level. The simulation results do not depend on network type structure (random or small world – however simulation outcomes for random networks have shown higher variance compared to small-world networks.

  9. Workers exposure to electric fields in 400 kV substations and overhead line works

    International Nuclear Information System (INIS)

    Elovaara, J.; Kuisti, H.; Korpinen, L.

    2010-01-01

    The maximum exposing electric field strength magnitude in the highly inhomogeneous 400 kV electric field under work conditions can reach the value of several tens of kV/m. In spite of this the average current density is, in Finland, always lower than 10 mA/m 2 . Furthermore, the total body currents or contact currents are in 400 kV works clearly less than the limit value proposed by the EU's draft for Directive. On the basis of the obtained results it can be concluded that from the limit value point of view it is not necessary to take further actions to reduce the exposure of the workers when they are working in 400 kV substations and on 400 kV overhead lines. However, because the transient peak values of the contact current can be painful and disturb work, it is advisable to develop a safe and reliable method to connect the worker and the work object in the common ground (equipotential bonding). (authors)

  10. Hazard zoning around electric substations of petrochemical industries by stimulation of extremely low-frequency magnetic fields.

    Science.gov (United States)

    Hosseini, Monireh; Monazzam, Mohammad Reza; Farhang Matin, Laleh; Khosroabadi, Hossein

    2015-05-01

    Electromagnetic fields in recent years have been discussed as one of the occupational hazards at workplaces. Hence, control and assessment of these physical factors is very important to protect and promote the health of employees. The present study was conducted to determine hazard zones based on assessment of extremely low-frequency magnetic fields at electric substations of a petrochemical complex in southern Iran, using the single-axis HI-3604 device. In measurement of electromagnetic fields by the single-axis HI-3604 device, the sensor screen should be oriented in a way to be perpendicular to the field lines. Therefore, in places where power lines are located in different directions, it is required to keep the device towards three axes of x, y, and z. For further precision, the measurements should be repeated along each of the three axes. In this research, magnetic field was measured, for the first time, in three axes of x, y, and z whose resultant value was considered as the value of magnetic field. Measurements were done based on IEEE std 644-1994. Further, the spatial changes of the magnetic field surrounding electric substations were stimulated using MATLAB software. The obtained results indicated that the maximum magnetic flux density was 49.90 μT recorded from boiler substation, while the minimum magnetic flux density of 0.02 μT was measured at the control room of the complex. As the stimulation results suggest, the spaces around incoming panels, transformers, and cables were recognized as hazardous zones of indoor electric substations. Considering the health effects of chronic exposure to magnetic fields, it would be possible to minimize exposure to these contaminants at workplaces by identification of risky zones and observation of protective considerations.

  11. Measurements of ELF electromagnetic exposure of the general public from Belgian power distribution substations.

    Science.gov (United States)

    Joseph, Wout; Verloock, Leen; Martens, Luc

    2008-01-01

    In this paper, the exposure of the general public due to distribution substations of 11/0.22-0.4 kV is investigated. The substations are categorized according to their location (substations in buildings, detached substations, substations between two houses, and underground substations in the pavement), and eight relevant substations are selected to perform measurements of the electromagnetic fields. The purpose of this paper is to determine the "minimum distances" for the general public--defined as the distances outside which the field levels do not exceed a certain field value--of these substations. In total, 637 field measurements were performed: 358 measurements of the magnetic field and 279 measurements of the electric field in different locations. Measured momentary magnetic field values are within the range of 0.025 to 47.39 microT. Electric fields are within the range 0.1 to 536 V m(-1). Also, magnetic field measurements as a function of the height above the ground were performed. The maximal magnetic (values over one day) and electric fields for all the investigated substations were below 100 microT and 5 kV m(-1), respectively. For exposure over a year, all substations except one delivered values below 100 microT. For the substation producing a magnetic field above 100 microT, a minimum distance of about 0.5 m was obtained. When comparing the average exposure with the value of 0.4 microT, minimum distances of maximally 5.4 m (average day) and 7.2 m (average year) were obtained.

  12. Workers' exposure to electric fields during the task 'maintenance of an operating device of circuit breaker from a service platform' at 110-kV substations.

    Science.gov (United States)

    Korpinen, Leena; Pääkkönen, Rauno

    2018-02-26

    The objective of the study was to investigate occupational exposure to electric fields during the task 'maintenance of an operating device of circuit breaker from a service platform' at 110-kV substations. The aim was also to compare the results to Directive 2013/35/EU. At 16 substations, 255 electric field measurements were performed. The highest mean value of the electric fields was 9.6 kV⋅m -1 . At 63% of substations the maximum values were over 10.0 kV⋅m -1 , and at 31% of the substations the 75th percentiles were over 10.0 kV⋅m -1 , which is the low action level (AL) according to Directive 2013/35/EU. All measured values were below the high AL (20.0 kV⋅m -1 ). In the future, it is important to take into account that the measurements were only taken at Finnish 110-kV substations; therefore, it is not possible to generalize these results to other countries and different types of substations.

  13. Powers of Traction Rectifier Substation of DC ELectric Railways 3kV

    Directory of Open Access Journals (Sweden)

    Josef Palecek

    2004-01-01

    Full Text Available The article states main principles of dimensioning of traction supply stations DC traction current system. it also provides detailed results of the traction rectifier substation Ostrava-Svinov load measurement. The measured valued are subsequently used for calculation of characteristic coefficients, whitch make it possible to dimension rectifier groups.

  14. Occupational exposure to electric and magnetic fields during work tasks at 110 kV substations in the Tampere region.

    Science.gov (United States)

    Korpinen, Leena H; Pääkkönen, Rauno J

    2010-04-01

    The occupational exposure to electric and magnetic fields during various work tasks at seven 110 kV substations in Finland's Tampere region was studied. The aim was to investigate if the action values (10 kV/m for the E-field and 500 microT for the B-field) of the EU Directive 2004/40/EC were exceeded. Electric and magnetic fields were measured during the following work tasks: (1) walking or operating devices on the ground; (2) working from a service platform; (3) working around the power transformer on the ground or using a ladder; and (4) changing a bulb from a man hoist. In work task 2 "working from a service platform" the measured electric field (maximum value 16.6 kV/m) exceeded 10 kV/m in three cases. In the future it is important to study if the limit value (10 mA/m(2)) of Directive 2004/40/EC is exceeded at 110 kV substations. The occupational 500 microT action value of the magnetic flux density field (B-field) was not exceeded in any working situation.

  15. Protection Coordination in Electrical Substation Part-2 Unit Protections (Differential and Distance Protection)

    OpenAIRE

    TÜR, Mehmet Rida; Shobole, Abdulfetah; Baysal, Mustafa; Wadi, Mohammed

    2018-01-01

    Power systemsmust be protected against faults to ensure quality and reliable generation,transmission and distribution of power systems. Power system protection is providedby the protection relays. This paper is the second part of the ProtectionCoordination study for the Siddik Kardesler Substation. The protection fortransmission lines, transformer, bus bars and customer feeders is provided byovercurrent protection, differential and distance protection schemes. In thispaper, issues related wit...

  16. Simulator for training operators of electric substation: an approach via RBC-Paraconsistent; Simulador para treinamento de operadores de subestacao eletrica: um enfoque via RBC-paraconsistente

    Energy Technology Data Exchange (ETDEWEB)

    Lambert-Torres, G.; Martins, H.G.; Coutinho, M.P.; Goulart, J.D.C.; Soares, F.M.A. [Universidade Federal de Itajuba (UNIFEI), MG (Brazil). Dept. de Engenharia Eletrica], Emails: germanoltorres@gmail.com, helgagonzaga@gmail.com, maurilio.coutinho@gmail.com, janaina157@yahoo.com.br, francis.azevedo@gmail.com

    2009-07-01

    This article presents a combination of two techniques applied artificial intelligence to solve problems to Restoration of an Electric Substation: Casebased Reasoning - CBR and the Four Values Annotated Paraconsistent Logic - 4vAPL. The process occurs in the connection functions of belief, disbelief, specialty and temporality to LPA4v in the retrieval of cases to determine process diagnostic of an RBC. The field of CBR is applied in a recovery of an electric substation. The LPA4v is the support applied in problems that have inconsistent information, partials and undefined. Thus this study is closer of the real situations.

  17. Water Pumping Stations, File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric substations, sewer plants, sewer pumpstations, water plants, water tanks http://www.harfordcountymd.gov/gis/Index.cfm, Published in 2011, 1:1200 (1in=100ft) scale, Harford County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Water Pumping Stations dataset current as of 2011. File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric substations, sewer...

  18. Sewerage Treatment Plants, File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric substations, sewer plants, sewer pumpstations, water plants, water tanks http://www.harfordcountymd.gov/gis/Index.cfm, Published in 2011, 1:600 (1in=50ft) scale, Harford County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Sewerage Treatment Plants dataset current as of 2011. File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric substations, sewer...

  19. Water Treatment Plants, File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric substations, sewer plants, sewer pumpstations, water plants, water tanks http://www.harfordcountymd.gov/gis/Index.cfm, Published in 2011, 1:1200 (1in=100ft) scale, Harford County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Water Treatment Plants dataset current as of 2011. File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric substations, sewer...

  20. Sewerage Pumping Stations, File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric substations, sewer plants, sewer pumpstations, water plants, water tanks http://www.harfordcountymd.gov/gis/Index.cfm, Published in 2011, 1:600 (1in=50ft) scale, Harford County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Sewerage Pumping Stations dataset current as of 2011. File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric substations, sewer...

  1. Economic and technical analysis of electric power substations` control and protection digital systems; Analise tecnico-economica de sistemas digitais de protecao e controle de subestacoes

    Energy Technology Data Exchange (ETDEWEB)

    Marchetti, Nelson Branco; Wochler, William Silveira [Siemens S.A., Sao Paulo, SP (Brazil)

    1995-12-31

    This work talks about the entrance of digital technology, in protection and control digital systems for electric power substations, in the Brazilian market. It makes a comparative evaluation between digital and conventional systems. Finally, the authors conclude that the digital systems present a better cost benefit rate considering not only financial but also functional aspects 4 refs., 1 fig.

  2. PUREX new substation ATR

    International Nuclear Information System (INIS)

    Nelson, D.E.

    1997-01-01

    This document is the acceptance test report (ATR) for the New PUREX Main and Minisubstations. It covers the factory and vendor acceptance and commissioning test reports. Reports are presented for the Main 5 kV substation building, the building fire system, switchgear, and vacuum breaker; the minisubstation control building and switch gear; commissioning test; electrical system and loads inspection; electrical utilities transformer and cable; and relay setting changes based on operational experience

  3. PUREX new substation ATR

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, D.E.

    1997-05-12

    This document is the acceptance test report (ATR) for the New PUREX Main and Minisubstations. It covers the factory and vendor acceptance and commissioning test reports. Reports are presented for the Main 5 kV substation building, the building fire system, switchgear, and vacuum breaker; the minisubstation control building and switch gear; commissioning test; electrical system and loads inspection; electrical utilities transformer and cable; and relay setting changes based on operational experience.

  4. Seismic damage in the electrical substations of the Colima state; Dano sismico en las subestaciones electricas del estado de Colima

    Energy Technology Data Exchange (ETDEWEB)

    Mena H, Ulises; Lopez L, Alberto; Guerrero F, Vicente A. [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2004-07-01

    On the 21 of January of 2003, at 20:06:36 hrs (Mexico center time) an earthquake occurred at the Pacific coast with a magnitude of 7.6 degrees in the Richter scale, whose epicenter was located near the state of Colima and it was felt in a large extent of the Mexican Republic. The earthquake caused numerous material damages in the structures (houses, churches, offices, etc) and vital lines, mainly in the infrastructure of the electrical sector of the region, leaving without electrical energy a large part of the nearby populations and some colonies of distant zones such as in Mexico City. The cause of the interruption of the electrical energy was due to the collapse of some of the equipment of 400 and 230 KV of the electrical transmission substations, among which are Manzanillo II and Colima II. With the experience acquired in the earthquake of October 9, 1995 in Manzanillo, in which also the facilities and equipment of the electrical substations were affected considerably, and as a part of the infrastructure project on the analysis of seismic risk of vital lines that is being developed at this moment at the Instituto de Investigaciones Electricas (IIE), it was decided to inspect the electrical substations of the zone, where the greater damages in the facilities and equipment were reported, to analyze and to determine the main causes of their failure. [Spanish] El 21 de enero de 2003, a las 20:06:36 hrs (hora del centro de Mexico) ocurrio un sismo en la costa del Pacifico con una magnitud de 7.6 grados en escala Richter, cuyo epicentro se localizo cerca del estado de Colima y se percibio en gran parte de la republica mexicana. El sismo causo cuantiosos danos materiales en las estructuras (viviendas, iglesias, oficinas, etc) y lineas vitales, principalmente en la infraestructura del sector electrico de la region, dejando sin energia electrica a gran parte de las poblaciones cercanas y algunas colonias de zonas lejanas como es la ciudad de Mexico. La causa del corte de

  5. Methodology for evaluating the grounding system in electrical substations; Metodologia para la evaluacion del sistema de puesta a tierra en subestaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Torrelles Rivas, L.F [Universidad Nacional Experimental Politecnica: Antonio Jose de Sucre (UNEXPO), Guayana, Bolivar (Venezuela)]. E-mail: torrellesluis@gmail.com; Alvarez, P. [Petroleos de Venezuela S.A (PDVSA), Maturin, Monagas (Venezuela)]. E-mail: alvarezph@pdvsa.com

    2013-03-15

    The present work proposes a methodology for evaluating grounding systems in electrical substations from medium and high voltage, in order to diagnose the state of the elements of the grounding system and the corresponding electrical variables. The assessment methodology developed includes a visual inspection phase to the elements of the substation. Then, by performing measurements and data analysis, the electrical continuity between the components of the substation and the mesh ground is verified, the soil resistivity and resistance of the mesh. Also included in the methodology the calculation of the step and touch voltage of the substation, based on the criteria of the International IEEE standards. We study the case of the 115 kV Pirital Substation belonging to PDVSA Oriente Transmission Network. [Spanish] En el presente trabajo se plantea una metodologia para la evaluacion de sistemas de puesta a tierra en subestaciones electricas de media y alta tension, con la finalidad de diagnosticar el estado de los elementos que conforman dicho sistema y las variables electricas correspondientes. La metodologia de evaluacion desarrollada incluye una fase de inspeccion visual de los elementos que conforman la subestacion. Luego, mediante la ejecucion de mediciones y analisis de datos, se verifica la continuidad electrica entre los componentes de la subestacion y la malla de puesta a tierra, la resistividad del suelo y resistencia de la malla. Se incluye tambien en la metodologia el calculo de las tensiones de paso y de toque de la subestacion, segun lo fundamentado en los criterios de los estandares Internacionales IEEE. Se estudia el caso de la Subestacion Pirital 115 kV perteneciente a la Red de Transmision de PDVSA Oriente.

  6. Examples of occupational exposure to electric and magnetic fields at 110-kV gas-insulated substations (GISs).

    Science.gov (United States)

    Korpinen, Leena; Pääkkönen, Rauno

    2015-02-01

    The objectives of the study were to present examples of occupational exposure to electric and magnetic fields at gas-insulated substations (GISs) and to analyse the exposure according to the new European Directive 2013/35/EU. The aim was also to describe the details of the measurements of this study at GISs. Electric and magnetic fields were measured (45 measurements in total) at two GISs in the Tampere region of Finland. Inside the GISs, magnetic field values varied from 0.4 to 43.0 µT, and electric fields from 5 to 90 V m(-1). In the cable room of GIS B, the maximum value was 250 µT (very near the cables). The values did not exceed the low or high action levels of the new Directive 2013/35/EU. In conclusion, it can be stated that at 110-kV GISs, workers are not exposed to electromagnetic fields (EMFs) higher than the new European Directive 2013/35/EU. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. System for the design of electrical distribution substations; Sistema para el diseno de subestaciones electricas de distribucion

    Energy Technology Data Exchange (ETDEWEB)

    Zayas Perez, Benjamin Eddie; Islas Perez, Eduardo; Bahena Rada, Jessica Liliana; Romero Lima, Jesus [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Sierra Rodriguez, Benjamin; Moreno Diaz, Humberto [Comision Federal de Electricidad (Mexico)

    2011-07-01

    The physical design of electric substations involves a variety of activities, such as developing, reviewing and performing modifications to different design proposals, estimating costs and producing documents to be integrated into an executive project. These activities are usually conducted at the Distribution Divisions of the Federal Electric Commission (CFE) through two separate processes: the development of engineering plans with computer-aided design software (CAD) and volumetric calculations for the initial budget using conventional spreadsheets. The documents are manually developed on an individual basis, without the existence of any functions to allow for automatically updating the design modifications of any of the plans. The corresponding initial budget becomes a lengthy and laborious process with the likelihood of inconsistencies among the documents. In order to optimize the design process for the public and electromechanical works of electric substations (ES) in a three-dimensional (3D) graphic environment, the IIE's Management of Process Supervision, in coordination with the CFE Distribution Subdivision, developed the System for the Design of Electric Substation Distribution (SDESD). This system makes use of the advantages of CAD3D technology to develop detail engineering, cost engineering to calculate initial budgets and virtual reality for three-dimensional interactive navigation. It is worth mentioning that this system is currently in the implementation phase at the CFE Distribution Subdivision. This article briefly describes the main stages in the development of the project, as well as the functioning and principal components of the system. [Spanish] El diseno fisico de subestaciones electricas implica una variedad de actividades, tales como elaborar, revisar y efectuar modificaciones de diferentes propuestas de diseno, estimar costos y producir documentos, para integrarlos como parte de un proyecto ejecutivo. Estas actividades usualmente se

  8. Automation of substation design

    Energy Technology Data Exchange (ETDEWEB)

    Milks, D. [Autodesk Inc., San Rafael, CA (United States); Scullion, T. [AutomationForce, Burlington, ON (Canada)

    2010-07-01

    Smart libraries and substation design tools are now being used by electric utilities to simplify and optimize the design of electrical control systems. A rules-based design and database approach was used to determine the placement of connections and for designing schematics, panel layouts wiring diagrams and cable schedules. Substation design solutions can reduce labour resources and field errors. Methods of synthesizing technologies in a database-centric architecture were discussed along with methods of selecting and adopting appropriate design technologies and methods for gaining efficiencies and managing change within organizations. The study demonstrated that the successful adoption of new technology requires a clear understanding of business objectives, technology requirements, and management support. 2 refs., 5 figs.

  9. Structural assessment of highway "N" power substation under earthquake loads.

    Science.gov (United States)

    2009-10-01

    In this study, the Highway N Substation was analyzed with a finite element model (FEM) for its vulnerability. The rigid bus and electric switch components were characterized with full scale shake table tests. Each component of the substation wa...

  10. A Comparative Study of Electric Load Curve Changes in an Urban Low-Voltage Substation in Spain during the Economic Crisis (2008–2013

    Directory of Open Access Journals (Sweden)

    Pedro M. Lara-Santillán

    2014-01-01

    Full Text Available This paper presents a comparative study of the electricity consumption (EC in an urban low-voltage substation before and during the economic crisis (2008–2013. This low-voltage substation supplies electric power to near 400 users. The EC was measured for an 11-year period (2002–2012 with a sampling time of 1 minute. The study described in the paper consists of detecting the changes produced in the load curves of this substation along the time due to changes in the behaviour of consumers. The EC was compared using representative curves per time period (precrisis and crisis. These representative curves were obtained after a computational process, which was based on a search for days with similar curves to the curve of a determined (base date. This similitude was assessed by the proximity on the calendar, day of the week, daylight time, and outdoor temperature. The last selection parameter was the error between the nearest neighbour curves and the base date curve. The obtained representative curves were linearized to determine changes in their structure (maximum and minimum consumption values, duration of the daily time slot, etc.. The results primarily indicate an increase in the EC in the night slot during the summer months in the crisis period.

  11. A Comparative Study of Electric Load Curve Changes in an Urban Low-Voltage Substation in Spain during the Economic Crisis (2008–2013)

    Science.gov (United States)

    Lara-Santillán, Pedro M.; Mendoza-Villena, Montserrat; Fernández-Jiménez, L. Alfredo; Mañana-Canteli, Mario

    2014-01-01

    This paper presents a comparative study of the electricity consumption (EC) in an urban low-voltage substation before and during the economic crisis (2008–2013). This low-voltage substation supplies electric power to near 400 users. The EC was measured for an 11-year period (2002–2012) with a sampling time of 1 minute. The study described in the paper consists of detecting the changes produced in the load curves of this substation along the time due to changes in the behaviour of consumers. The EC was compared using representative curves per time period (precrisis and crisis). These representative curves were obtained after a computational process, which was based on a search for days with similar curves to the curve of a determined (base) date. This similitude was assessed by the proximity on the calendar, day of the week, daylight time, and outdoor temperature. The last selection parameter was the error between the nearest neighbour curves and the base date curve. The obtained representative curves were linearized to determine changes in their structure (maximum and minimum consumption values, duration of the daily time slot, etc.). The results primarily indicate an increase in the EC in the night slot during the summer months in the crisis period. PMID:24895677

  12. Guidelines for the development of applicative software for supervising and remote electric power substations; Diretrizes de desenvolvimento de softwares aplicativos para as estacoes supervisoras e remotas

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Guilherme Moutinho; Soares, Wellington Zakhia; Morais, Arnoldo Magela [Companhia Energetica de Minas Gerais (CEMIG), Belo Horizonte, MG (Brazil)

    1995-12-31

    The increasing application of remote control supervision systems composed of regional operation centers (COR) and remote terminal units (UTR) creates the adequate conditions for the development and implementation of operational engineering functions in electric power substations (SE). In order to provide the necessary elements for such qualitative improvement, this work presents guidelines for the development of applicative soft-wares for the local control and supervision to be installed in CORs and UTRS, based in CEMIG`s, the electric power company of Minas Gerais State - Southeast Brazil, experience 4 refs.

  13. 7 CFR 1726.77 - Substation and transmission line construction.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Substation and transmission line construction. 1726... UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC SYSTEM CONSTRUCTION POLICIES AND PROCEDURES Substation and Transmission Facilities § 1726.77 Substation and transmission line construction. (a) Contract...

  14. Electric field analysis of extra high voltage (EHV) underground cables using finite element method

    DEFF Research Database (Denmark)

    Kumar, Mantosh; Bhaskar, Mahajan Sagar; Padmanaban, Sanjeevikumar

    2017-01-01

    used for the insulator due electrical, thermal or environmental stress. Most of these problems are related to the electric field stress on the insulation of the underground cables. The objective of the electric field analysis by using different numerical techniques is to find electric field stress...... electric field stress and other parameters of EHV underground cables with given boundary conditions using 2-D electric field analysis software package (IES-ELECTRO module) which is based on the finite element method (FEM).......Transmission and Distribution of electric power through underground cables is a viable alternative to overhead lines, particularly in residential or highly populated areas. The electrical stresses are consequences of regular voltages and over voltages and the thermal stresses are related to heat...

  15. Design of earth network in electric substations; Diseno de redes de tierra en subestaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Raull-Martin, J. [Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    2000-09-01

    The purpose of this paper is to present a summarized version of the different types of construction of grounding systems, as web as their materials and formulas, which are necessary and useful for the design and building of a grounding network for medium to high voltage facilities. A description is also made of how to determine the electrical resistivity of subsoil layers with different physical characteristics. Several illustrative examples are also solved in the paper. [Spanish] El proposito de este articulo es presentar de manera resumida los diferentes tipos de construccion de los sistemas de tierra, asi como sus materiales y formulas, los cuales son necesarios y utiles para el diseno y edificacion de una red de tierra para instalaciones de mediana y alta tension. Se describe tambien la obtencion de las diferentes resistividades que presentan los terrenos con diversas caracteristicas fisicas. Asi mismo, se solucionan ejercicios ilustrativos a lo largo del articulo.

  16. 30 CFR 75.340 - Underground electrical installations.

    Science.gov (United States)

    2010-07-01

    ... Section 75.340 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.340 Underground...) Ventilated with intake air that is monitored for carbon monoxide or smoke by an AMS installed and operated...

  17. Ashland Area Support Substation Project

    International Nuclear Information System (INIS)

    1992-06-01

    The Bonneville Power Administration (BPA) provides wholesale electric service to the City of Ashland (the City) by transferring power over Pacific Power ampersand Light Company's (PP ampersand L) 115-kilovolt (kV) transmission lines and through PP ampersand L's Ashland and Oak Knoll Substations. The City distributes power over a 12.5-kV system which is heavily loaded during winter peak periods and which has reached the limit of its ability to serve peak loads in a reliable manner. Peak loads under normal winter conditions have exceeded the ratings of the transformers at both the Ashland and Oak Knoll Substations. In 1989, the City modified its distribution system at the request of PP ampersand L to allow transfer of three megawatts (MW's) of electric power from the overloaded Ashland Substation to the Oak Knoll Substation. In cooperation with PP ampersand L, BPA installed a temporary 6-8 megavolt-amp (MVA) 115-12.5-kV transformer for this purpose. This additional transformer, however, is only a temporary remedy. BPA needs to provide additional, reliable long-term service to the Ashland area through additional transformation in order to keep similar power failures from occurring during upcoming winters in the Ashland area. The temporary installation of another 20-MVA mobile transformer at the Ashland Substation and additional load curtailment are currently being studied to provide for sustained electrical service by the peak winter period 1992. Two overall electrical plans-of-service are described and evaluated in this report. One of them is proposed for action. Within that proposed plan-of-service are location options for the substation. Note that descriptions of actions that may be taken by the City of Ashland are based on information provided by them

  18. Project FOOTPRINT: Substation modeling and simulations for E1 pulses

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Scott D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Larson, D. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kirkendall, B. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-11-06

    This report includes a presentation with an: Introduction to CW coupling; Introduction to single-pulse coupling; Description of E1 waveforms; Structures in a substation yard --articulated (as part of the substation's defined electrical functionality)--unarticulated (not as part of the substation's defined electrical functionality); Coupling --electrical coupling (capacitive coupling) --magnetic coupling (inductive coupling); Connectivity to long-line transmission lines; Control infrastructure; Summary; and References.

  19. Numerical evaluation of currents induced in a worker by ELF non-uniform electric fields in high voltage substations and comparison with experimental results.

    Science.gov (United States)

    Tarao, Hiroo; Korpinen, Leena H; Kuisti, Harri A; Hayashi, Noriyuki; Elovaara, Jarmo A; Isaka, Katsuo

    2013-01-01

    An ungrounded human, such as a substation worker, receives contact currents when touching a grounded object in electric fields. In this article, contact currents and internal electric fields induced in the human when exposed to non-uniform electric fields at 50 Hz are numerically calculated. This is done using a realistic human model standing at a distance of 0.1-0.5 m from the grounded conductive object. We found that the relationship between the external electric field strength and the contact current obtained by calculation is in good agreement with previous measurements. Calculated results show that the contact currents largely depend on the distance, and that the induced electric fields in the tissues are proportional to the contact current regardless of the non-uniformity of the external electric field. Therefore, it is concluded that the contact current, rather than the spatial average of the external electric field, is more suitable for evaluating electric field dosimetry of tissues. The maximum induced electric field appears in the spinal cord in the central nervous system tissues, with the induced electric field in the spinal cord approaching the basic restriction (100 mV/m) of the new 2010 International Commission on Non-Ionizing Radiation Protection guidelines for occupational exposure, if the contact current is 0.5 mA. Copyright © 2012 Wiley Periodicals, Inc.

  20. Dynamic underground stripping: steam and electric heating for in situ decontamination of soils and groundwater

    Science.gov (United States)

    Daily, W.D.; Ramirez, A.L.; Newmark, R.L.; Udell, K.; Buetnner, H.M.; Aines, R.D.

    1995-09-12

    A dynamic underground stripping process removes localized underground volatile organic compounds from heterogeneous soils and rock in a relatively short time. This method uses steam injection and electrical resistance heating to heat the contaminated underground area to increase the vapor pressure of the contaminants, thus speeding the process of contaminant removal and making the removal more complete. The injected steam passes through the more permeable sediments, distilling the organic contaminants, which are pumped to the surface. Large electrical currents are also applied to the contaminated area, which heat the impermeable subsurface layers that the steam has not penetrated. The condensed and vaporized contaminants are withdrawn by liquid pumping and vacuum extraction. The steam injection and electrical heating steps are repeated as necessary. Geophysical imaging methods can be used to map the boundary between the hot, dry, contamination-free underground zone and the cool, damp surrounding areas to help monitor the dynamic stripping process. 4 figs.

  1. Ergonomic analyse of operation work in electric energy transmission substation; Analise ergonomica do trabalho de operacao de subestacoes de transmissao de energia eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Menegon, Nilton Luiz

    1993-04-01

    The activity by the workers in sub-stations which transmits and distributes electric energy is studied within the context of ergonomic, i.e., of its adequateness to the human being characteristics. In the introduction of this book the ideas of ergonomic related to the behaviour of the workers who works which continuous processes in control room are reviewed. The development of the ideas in this field as well as the methodology to be followed in this work are discussed. The technical system involving the activities of the workers in sub-station is presented. These activities are inserted within a broad context of the electric energy sector. An analysis concerning the problems in the ergonomic field which justifies the ergonomic intervention follows the previous study. The work situation is characterized. The formal organization of the work and its physical and cognitive demands are examined. The task is explained in detail. With the analysis of the activities based on the systematic observation of the work performed by the workers, we finish this study. Finely, a diagnosis of the work situation and the recommendations compromised whit the workers health and improvement of the performance is settled. (author) 27 refs., 26 figs.

  2. Long-term exposure to electric fields. A cross-sectional epidemiologic investigation of occupationally exposed workers in high-voltage substations.

    Science.gov (United States)

    Knave, B; Gamberale, F; Bergström, S; Birke, E; Iregren, A; Kolmodin-Hedman, B; Wennberg, A

    1979-06-01

    In the present epidemiologic study, 53 workers with a long-term (more than five years) exposure to the electric field of 400 kV substations were examined and compared with a matched reference group of 53 nonexposed workers from the same power companies. Matching variables included age, geographic location and employment time. The aim of the study was to investigate the possibility of persistent, chronic health effects in the exposed group as a consequence of exposure. The investigation indluded the nervous system (neurasthenic symptoms, psychological tests, electroencephalography), the cardiovascular system (symptoms, blood pressure, electrocardiography), and the blood (hemoglobin, red blood cells, reticulocytes, white blood cells including differential count, thrombocytes, sedimentation rate). Fertility was also assessed. The results showed no differences between the exposed and reference groups as a consequence of the long-term exposure to the electric fields. The groups differed, however, in that the exposed group had (a) consistently better results on the psychological performance tests, (b) a fewer number of children, especially boys, and (c) somewhat higher education. The differences in test results were due to the higher education among the exposed. The difference in number of children was also thought to be related to factors other than exposure since it was found to be present already 10--15 years before the work in 400 kV substations began.

  3. Methodology and tests for electric distances reduction among phases of bus bar of 138 kV indoors substations; Metodologia e testes para reducao das distancias eletricas entre fases de barramentos de substacoes de 138 kV abrigadas

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Andre Nunes de

    1995-07-01

    Due to a natural imposition caused by socio-economical aspects the reduction of the area used by substations in places densely populated, is becoming a must. Considering that the Institute of Electrotechnical and Energy of the University of Sao Paulo, Brazil, has been developing a project for 138 kV indoors substations which has, in its first stage, observed closely the performance of high voltage tests. aiming at the reduction of the electric distances (phase-phase and phase-ground) of the referred bus bar substations. This paper initially presents a methodology applied in these tests as follows: origin of the atmospheric discharges, philosophy of the high voltage tests, high voltage laboratory particularities, over voltages, tests standardization, atmospheric influences on tests results, statistics, types of bus bar to be tested, etc..Finally, the tests performed are then described and the obtained results presented, proving that the electrical distances between phases could be significantly reduced. (author)

  4. Applying of Electrical Imaging Survey (EIS) to Evaluate Leachate Pollution in Underground Area of Informal Landfill

    DEFF Research Database (Denmark)

    Du, Song; Wang, Di; Mou, Zishen

    2014-01-01

    An informal landfill is an open dump that pollutes the underground environment because it lacks an impervious liner. The leakage of such a landfill is unidirectional and thus difficult to directly test. This study uses electrical imaging survey to evaluate the pollution of the underground...... environment of an informal landfill for municipal solid waste in Beijing. We hypothesize that every location has a specific resistivity resulting from the leachate. We use the membership function of fuzzy mathematics to quantitatively represent the pollution of the underground environment in the sanitary...... landfill. The results are consistent with borehole data....

  5. Occupational exposure to electric and magnetic fields during tasks at ground or floor level at 110 kV substations in Finland.

    Science.gov (United States)

    Korpinen, Leena; Pääkkönen, Rauno

    2016-09-01

    The aim was to investigate occupational exposure to electric and magnetic fields during tasks at ground or floor level at 110 kV substations in Finland and to compare the measured values to Directive 2013/35/EU. Altogether, 347 electric field measurements and 100 magnetic field measurements were performed. The average value of all electric fields was 2.3 kV/m (maximum 6.4 kV/m) and that of magnetic fields was 5.8 µT (maximum 51.0 µT). It can be concluded that the electric and magnetic field exposure at ground or floor level is typically below the low action levels of Directive 2013/35/EU. The transposition of the directive will not create new needs to modify the work practice of the evaluated tasks, which can continue to be performed as before. However, for workers with medical implants, the exposure may be high enough to cause interference.

  6. Material and Energy Flow Analysis (Mefa of the Unconventional Method of Electricity Production Based on Underground Coal Gasification

    Directory of Open Access Journals (Sweden)

    Krystyna Czaplicka-Kolarz

    2014-01-01

    Originality/value: This is the first approach which contains a whole chain of electricity production from Underground Coal Gasification, including stages of gas cleaning, electricity production and the additional capture of carbon dioxide.

  7. Study of overvoltages by phenomenon of ferroresonance in the substation Filadelfia of the Sistema Electrico Nacional

    International Nuclear Information System (INIS)

    Montealegre Lobo, Leonardo

    2012-01-01

    The mathematical analysis of the phenomenon of ferroresonance is far from easy especially when is looked an exact solution and is wanted to take into account all relevant considerations, that the characteristic of non-linearity has presented in this phenomenon. However, a series of appropriate simplifications are conducted and is possible simulate successfully variables of interest, in this case, voltages and currents. Personnel of the Area Proteccion y Medicion, Region Chorotega of the UEN Transporte Electrico (UEN TE) has approached the Centro de Investigacion en Sistemas de Potencia to be provided by a technical support in understanding (cause and possible mitigation) of a transient event that has caused the arrester output of the Subestacion Filadelfia after conducting an energization operation in said substation. The main supply by the personnel of the UEN TE has been the current measurement of fault recorder of differential protection of power transformer, the wave forms current are recorded 100 ms before, during and 200 ms after the occurrence of the event that has blown the lightning rods low side of the substation power transformer. Research has allowed to generate the simplifications needed to reconstruct the event occurred in substation in the absence of the voltage measurements of recorded event, the magnetization curve of the transformers, the electrical characteristics of underground cables and lightning rod present in the substation. Ranges are detailed on the determination of the reasons that have caused the explosion of lightning rods in the rod 13.8 kV of substation Filadelfia when maneuvering connection of electrical equipment for energization Ingenio El Viejo. Recommendations are offered for minimizing the effects caused by these maneuvers. (author) [es

  8. EHV AC undergrounding electrical power performance and planning

    CERN Document Server

    Benato, Roberto

    2014-01-01

    Analytical methods of cable performance in EHV AC electrical power are discussed in this comprehensive reference. Descriptions of energization, power quality, cable safety constraints and more, guide readers in cable planning and power network operations.

  9. Digital Metering System of New Generation Smart Substation in China

    Directory of Open Access Journals (Sweden)

    Bai Jingfen

    2016-01-01

    Full Text Available The new generation of smart substation is a summary and improvement of the earlier intelligent substations within the past 5 years. As a part of the substation operation function, the electric energy metering system must adapt to the requirements of the new generation smart substation which is more intelligent, full digitalization, networked and integrated. With the features of digitized, easy information sharing, and hardware shared, the digital measurement system is the inevitable choice for the new generation smart substation. This paper is the first literature to introduce the concept and structure of the digital metering system. The composition and technical characteristics of the new generation Smart Substation measurement system are introduced in detail.

  10. The Increase of Power Efficiency of Underground Coal Mining by the Forecasting of Electric Power Consumption

    Science.gov (United States)

    Efremenko, Vladimir; Belyaevsky, Roman; Skrebneva, Evgeniya

    2017-11-01

    In article the analysis of electric power consumption and problems of power saving on coal mines are considered. Nowadays the share of conditionally constant costs of electric power for providing safe working conditions underground on coal mines is big. Therefore, the power efficiency of underground coal mining depends on electric power expense of the main technological processes and size of conditionally constant costs. The important direction of increase of power efficiency of coal mining is forecasting of a power consumption and monitoring of electric power expense. One of the main approaches to reducing of electric power costs is increase in accuracy of the enterprise demand in the wholesale electric power market. It is offered to use artificial neural networks to forecasting of day-ahead power consumption with hourly breakdown. At the same time use of neural and indistinct (hybrid) systems on the principles of fuzzy logic, neural networks and genetic algorithms is more preferable. This model allows to do exact short-term forecasts at a small array of input data. A set of the input parameters characterizing mining-and-geological and technological features of the enterprise is offered.

  11. 3D As-Built a documentation of the substation electrical power 400 KV; Documentacion 3D As-Built de una subestacion electrica de 400 KV

    Energy Technology Data Exchange (ETDEWEB)

    Sarti Fernandez, F.

    2011-07-01

    It's getting parameters of time, yields and products obtained, in order to have an objective reference to the possible application of this technique to substations of Red Electrica Espanola (REE).

  12. Quality frontier of electricity distribution: Supply security, best practices, and underground cabling in Finland

    International Nuclear Information System (INIS)

    Saastamoinen, Antti; Kuosmanen, Timo

    2016-01-01

    Electricity distribution is a prime example of local monopoly. In most countries, the costs of electricity distribution operators are regulated by the government. However, the cost regulation may create adverse incentives to compromise the quality of service. To avoid this, cost regulation is often amended with quality incentives. This study applies theory and methods of productivity analysis to model the frontier of service quality. A semi-nonparametric estimation method is developed, which does not assume any particular functional form for the quality frontier, but can accommodate stochastic noise and heteroscedasticity. The empirical part of our paper examines how underground cabling and location affect the interruption costs. As expected, higher proportion of underground cabling decreases the level of interruption costs. The effects of cabling and location on the variance of performance are also considered. Especially the location is found to be a significant source of heteroscedasticity in the interruption costs. Finally, the proposed quality frontier benchmark is compared to the current practice of Finnish regulation system. The proposed quality frontier is found to provide more meaningful and stable basis for setting quality targets than the average practice benchmarks currently in use. - Highlights: • Cost regulation may create adverse incentives to lower the service quality. • We model the frontier of service quality using a semi-nonparametric approach. • Our nonparametric frontier accounts for stochastic noise and heteroscedasticity. • We estimate how underground cabling and location affect interruption costs. • We compare our quality frontier with the current quality regulation in Finland.

  13. Design of substation foundations for liquefaction

    International Nuclear Information System (INIS)

    Burton, P.; Buhr, C.

    1991-01-01

    This paper reports that when substation foundations penetrate liquefiable strata within risk prone seismic regions, the potential loss of support must be evaluated with state-of-the-art methods to determine foundation reliability during critical earthquake events. Drilled shaft foundations subject to relatively large overturning moments, compression loads, and uplift loads at the Bennettsville 230/69-kV substation in Marlboro County, South Carolina were designed to accommodate the corresponding loss in soil strength resulting from liquefaction of underlying, loose, saturated sands. The LIQUEFY2 program was used to predict which strata are prone to liquefaction. Additional substation locations in South Carolina have been evaluated for this same regional electric utility client. However, not all of these sites have been found to contain liquefiable soils. Liquefaction risk analysis and reliable foundation design are subject to site specific design requirements

  14. INTELLIGENT DIAGNOSTIC SYSTEM OF EMERGENCY SITUATIONS IN TRACTION SUBSTATIONS DC

    Directory of Open Access Journals (Sweden)

    Sh. N. Nasyrov

    2009-09-01

    Full Text Available In the article the architecture and algorithm of operating an expert system providing the efficiency of functioning the electric equipment for traction substation as well as the four-parameter belonging function are determined.

  15. Canby Area Service Project substation and associated transmission line

    International Nuclear Information System (INIS)

    1992-02-01

    Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp's substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC's Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC's substation can accommodate only about 10 percent of the expected additional electric load. BPA's proposed action is intended to meet SVEC's increasing electric load. BPA proposes to meet SVEC's increasing energy load by tapping into BPA's existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC's Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no ''environmental impact statement'' is not required

  16. Application of unimodal optic fiber to communications among electric substations; Aplicacion de fibra optica unimodal a comunicaciones entre subestaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Pinon, Fernando; Hernandez Juarez, Taide [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1992-07-01

    The utilization of the unimodal fiber optics technology in the electric power systems, represents one of the best communication options because of its multiple advantages, that results in a better coordination of the technical and administrative activities, needed to carry the electric energy from its generation site to the most remote locations. In this document a study, in accordance with the available options for the design of communication systems via unimodal optic fiber, is presented. With this technology, ties of more than 100 kilometers without the need of repeating stations, can be made. [Espanol] La utilizacion de la tecnologia de fibra optica unimodal en los sistemas electricos de potencia representa una de las mejores alternativas de comunicacion por sus multiples ventajas que se traducen en una mejor coordinacion de las acitividades tecnicas y administrativas necesarias para llevar la energia electrica desde el lugar de generacion hasta los puntos mas distantes. En este documento se presenta un estudio de acuerdo a las opciones disponibles para el diseno de sistemas de comunicacion por fibra optica unimodal. Con esta tecnologia se pueden realizar enlaces mayores que 100 km sin necesidad de repetidores.

  17. Effect of increased electric loads on primary substation equipment in 100-B, C, D, DR, F, and H areas

    Energy Technology Data Exchange (ETDEWEB)

    Baker, D.S.; McLenegan, D.W.

    1956-07-05

    The loading on the primary transformers which step down the 230 kv transmission voltage to a distribution voltage of 13.8 kv, at 100-B-C, 100-D-DR, 100-F, and 100-H Areas will be increased by the synchronous motors now being installed in those areas under Project CG-558. This report summarizes: The changes in electric loads (both kv and power factor) which will result when the new motors are placed in service and certain older motors are withdrawn from service. Electric loads are tabulated in section 4.0 for each area for present conditions, the planned changes and the post-CG-558 conditions. The reduction of distribution voltage during the starting of individual 4500 hp synchronous motors. Since the synchronous motors will be started across the line as induction motors, the starting current will be high, and at a low power factor. Voltage drops are calculated for the starting of a synchronous motor, with one and then with two transformer banks paralleled. The current-interrupting capacity of switchgear vs. the maximum short-circuit current which could occur with separate transformers and with two primary transformers in parallel.

  18. Use of electrical resistivity to detect underground mine voids in Ohio

    Science.gov (United States)

    Sheets, Rodney A.

    2002-01-01

    Electrical resistivity surveys were completed at two sites along State Route 32 in Jackson and Vinton Counties, Ohio. The surveys were done to determine whether the electrical resistivity method could identify areas where coal was mined, leaving air- or water-filled voids. These voids can be local sources of potable water or acid mine drainage. They could also result in potentially dangerous collapse of roads or buildings that overlie the voids. The resistivity response of air- or water-filled voids compared to the surrounding bedrock may allow electrical resistivity surveys to delineate areas underlain by such voids. Surface deformation along State Route 32 in Jackson County led to a site investigation, which included electrical resistivity surveys. Several highly resistive areas were identified using axial dipole-dipole and Wenner resistivity surveys. Subsequent drilling and excavation led to the discovery of several air-filled abandoned underground mine tunnels. A site along State Route 32 in Vinton County, Ohio, was drilled as part of a mining permit application process. A mine void under the highway was instrumented with a pressure transducer to monitor water levels. During a period of high water level, electrical resistivity surveys were completed. The electrical response was dominated by a thin, low-resistivity layer of iron ore above where the coal was mined out. Nearby overhead powerlines also affected the results.

  19. National SCADA Test Bed Substation Automation Evaluation Report

    Energy Technology Data Exchange (ETDEWEB)

    Kenneth Barnes; Briam Johnson

    2009-10-01

    Increased awareness of the potential for cyber attack has recently resulted in improved cyber security practices associated with the electrical power grid. However, the level of practical understanding and deployment of cyber security practices has not been evenly applied across all business sectors. Much of the focus has been centered on information technology business centers and control rooms. This report explores the current level of substation automation, communication, and cyber security protection deployed in electrical substations throughout existing utilities in the United States. This report documents the evaluation of substation automation implementation and associated vulnerabilities. This evaluation used research conducted by Newton-Evans Research Company for some of its observations and results. The Newton Evans Report aided in the determination of what is the state of substation automation in North American electric utilities. Idaho National Laboratory cyber security experts aided in the determination of what cyber vulnerabilities may pose a threat to electrical substations. This report includes cyber vulnerabilities as well as recommended mitigations. It also describes specific cyber issues found in typical substation automation configurations within the electric utility industry. The evaluation report was performed over a 5-month period starting in October 2008

  20. Electric personnel carrier introduced : RES Equipment Sales spearheads development of electric underground vehicle

    International Nuclear Information System (INIS)

    Tollinsky, N.

    2010-01-01

    RES Equipment Sales of Dryden, Ontario is leading the development of a battery-powered personnel utility vehicle for underground mining applications. Among the advantages of the battery-powered personnel carrier are quietness of the carrier and zero emissions, which eliminates particulates from diesel engines and reduces the need for ventilation. This article discussed the design and building of the vehicle. It was designed to accommodate up to 3 battery packs, depending on the frequency of use. Swapping batteries takes between 2 or 3 minutes. Spent batteries must be plugged in for 6 hours and rest for another 6 to 8 hours before being ready for service. The vehicle accommodates 2 or 3 people and travels at speeds of 6 to 8 miles per hour. This article also provided background information on RES Equipment Sales. The company remanufactures underground mining equipment, including load-haul-dump machines, jumbos, haul trucks and utility vehicles. In addition, the company sells and services new equipment, including Oldenburg Cannon jumbos, scalers and utility vehicles, as well as Canun International pneumatic rock drills and NPK rock breakers. 1 ref., 1 fig.

  1. Factors influencing the reliability of non-electric detonating circuit in underground uranium mines and preventive measures of misfiring

    International Nuclear Information System (INIS)

    Li Qin

    2010-01-01

    Characteristics of non-electric detonating circuit are introduced. The main factors influencing the reliability of non-electric detonating circuit are described. Taking an underground blasting of a uranium mine for example, the reliability of various kinds of detonating network system is calculated using the reliability theory and numerical analysis method. The reasons that cause the misfiring in non-electric detonating circuit system are analyzed, and preventive measures are put forward.(authors)

  2. Study on noise prediction model and control schemes for substation.

    Science.gov (United States)

    Chen, Chuanmin; Gao, Yang; Liu, Songtao

    2014-01-01

    With the government's emphasis on environmental issues of power transmission and transformation project, noise pollution has become a prominent problem now. The noise from the working transformer, reactor, and other electrical equipment in the substation will bring negative effect to the ambient environment. This paper focuses on using acoustic software for the simulation and calculation method to control substation noise. According to the characteristics of the substation noise and the techniques of noise reduction, a substation's acoustic field model was established with the SoundPLAN software to predict the scope of substation noise. On this basis, 4 reasonable noise control schemes were advanced to provide some helpful references for noise control during the new substation's design and construction process. And the feasibility and application effect of these control schemes can be verified by using the method of simulation modeling. The simulation results show that the substation always has the problem of excessive noise at boundary under the conventional measures. The excess noise can be efficiently reduced by taking the corresponding noise reduction methods.

  3. Study on Noise Prediction Model and Control Schemes for Substation

    Science.gov (United States)

    Gao, Yang; Liu, Songtao

    2014-01-01

    With the government's emphasis on environmental issues of power transmission and transformation project, noise pollution has become a prominent problem now. The noise from the working transformer, reactor, and other electrical equipment in the substation will bring negative effect to the ambient environment. This paper focuses on using acoustic software for the simulation and calculation method to control substation noise. According to the characteristics of the substation noise and the techniques of noise reduction, a substation's acoustic field model was established with the SoundPLAN software to predict the scope of substation noise. On this basis, 4 reasonable noise control schemes were advanced to provide some helpful references for noise control during the new substation's design and construction process. And the feasibility and application effect of these control schemes can be verified by using the method of simulation modeling. The simulation results show that the substation always has the problem of excessive noise at boundary under the conventional measures. The excess noise can be efficiently reduced by taking the corresponding noise reduction methods. PMID:24672356

  4. Evidence of underground electric current generation during the 2009 L'Aquila earthquake: Real or instrumental?

    Science.gov (United States)

    Masci, F.; Thomas, J. N.

    2016-06-01

    We investigate magnetic effects in correspondence of the Mw6.1 L'Aquila earthquake. Magnetic and seismic records are analyzed. Rapid and distinct changes and an offset can be seen in magnetic field components after the main shock. We show that these effects result from electromagnetic induction due to the movement of the sensors through the Earth's magnetic field and from a permanent displacement of the sensors from their original position caused by the passing seismic waves. A transient signal in total field data from an overhauser magnetometer apparently occurs in correspondence with the earthquake. Our analysis shows that the transient was not observed by other sensors that were operating in close proximity to the overhauser. Thus, the transient signal in the total magnetic field data, and the offset in the magnetic field components, cannot be associated with a hypothetical underground electric current generated by the earthquake, as suggested by Nenovski (2015).

  5. 20 CFR 631.50 - Substate plan.

    Science.gov (United States)

    2010-04-01

    ... THE JOB TRAINING PARTNERSHIP ACT Substate Programs § 631.50 Substate plan. (a) In order to receive an...)). (g) If a substate grantee fails to meet the requirements for plan submission and approval found in...

  6. Characterisation by time-frequency analysis of the EM disturbances produced by railway substations

    OpenAIRE

    HAMMI, T; DENIAU, V; OUADDI, H; BARANOWSKI, S; RIOULT, J; AYAD, M; NOTTET, G

    2010-01-01

    This paper aims to propose a methodology to characterize the electromagnetic disturbances which are provided by the railway substations which supply the railway electrical infrastructure. Currents measurements were performed inside a substation in order to identify the harmonics and the transient signals which are created by the power devices of the substation. Finally, this paper suggests exploiting a timefrequency analysis to automatically detect transient signals.

  7. A risk measurement tool for an underground electricity distribution system considering the consequences and uncertainties of manhole events

    International Nuclear Information System (INIS)

    Garcez, Thalles Vitelli; Teixeira de Almeida, Adiel

    2014-01-01

    This paper explores a risk measure of underground vaults that considers the consequences of arc faults. The increasing use of underground systems, together with the aging of networks, the lack of maintenance and interference from other (third party) underground systems nearby have caused many accidents in urban areas, thus endangering human life. The involvement of a large number (hundreds or thousands) of underground vaults with different characteristics, the lack of historical data on modes of failure, the rarity of the occurrence of some faults, the magnitude of their consequences and the involvement of a complex environment surrounding the hazard zone make risk management even more complex and uncertain. Furthermore, given that the (monetary, time, staff, etc.) resources of an electrical power company are limited and scarce, it is necessary to use decision-making tools that aggregate the consequences and the uncertainties to assess the risks jointly with the preference structure of the company, thus solving the problem more realistically. Therefore, this paper puts forward the use of an additional risk analysis for manhole events in underground electrical distribution networks with a view to its being used as a decision aid tool in risk management. As an illustration of the use of the risk measurement tool proposed, a numerical application is presented. The result rather than showing a ranking of underground vaults, gives a measure of the risk used that can show the decision-maker (DM) how much better one group of alternatives (formed by alternatives with quite similar risk values) is than other groups, based on the DM’s attitude to risk and grounded on the axiomatic structure of utility theory. - Highlights: • The paper proposes a risk measure of underground vaults for manhole events. • It makes risk analysis in underground electrical distribution networks. • It makes more than show a risk ranking of underground vaults. • It can show to the DM how

  8. Neural networks for fault location in substations

    Energy Technology Data Exchange (ETDEWEB)

    Alves da Silva, A.P.; Silveira, P.M. da; Lambert-Torres, G. [Escola Federal de Engenharia de Itajuba (Brazil); Insfran, A.H.F.

    1996-01-01

    Faults producing load disconnections or emergency situations have to be located as soon as possible to start the electric network reconfiguration, restoring normal energy supply. This paper proposes the use of artificial neural networks (ANNs), of the associative memory type, to solve the fault location problem. The main idea is to store measurement sets representing the normal behavior of the protection system, considering the basic substation topology only, into associated memories. Afterwards, these memories are employed on-line for fault location using the protection system equipment status. The associative memories work correctly even in case of malfunction of the protection system and different pre-fault configurations. Although the ANNs are trained with single contingencies only, their generalization capability allows a good performance for multiple contingencies. The resultant fault location system is in operation at the 500 kV gas-insulated substation of the Itaipu system.

  9. CITEQ creates a transformer for underground electric networks: a joint initiative by Hydro-Quebec and ABB

    International Nuclear Information System (INIS)

    Cordeau, P.

    1997-01-01

    Advances in technology regarding underground transformers was discussed. After more than 3 years of research, CITEQ (Centre d'innovation sur le transport d'energie du Quebec), a new company founded by Hydro-Quebec and ABB, is on the verge of a breakthrough with a new submersible transformer with solid insulation. This transformer was specially designed for use in underground electric networks. The new transformer is a good alternative to conventional oil transformers which have a high risk of pollution mainly due to corrosion, leaks, explosions or fires. Also, the outer shell of the new transformer is composed of composite material which will eliminate the need for maintenance. The service life of the new transformer is expected to be approximately 30 to 40 years. CITEQ is hoping that this new technology will benefit the residential sector which is powered by underground distribution networks. 1 fig

  10. Investigation and comparison of the main corrosion processes on different electric power substations of the Rio Grande de Sul state, Brazil; Investigacao e comparacao dos principais processos de corrosao em diferentes subestacoes de energia eletrica do estado do Rio Grande do Sul

    Energy Technology Data Exchange (ETDEWEB)

    Brusamarello, Valner; Bianchi, Andre L.; Rieder, Ester S.; Balbinot, Alexandre; Wentz, Marcio; Konig, Diogo; Radke, Carlos [Universidade Luterana do Brasil (Ulbra), Canoas, RS (Brazil)

    2006-07-01

    In this work experiments have been developed on four electric power substations, three located at the coastal of the state of Rio Grande do Sul and one at the capital od the state, Porto Alegre city. The study had the objective to determine the corrosion ratios of the different metallic materials exposed to aggressive agents of the environment where the substations are exposed, and to determine the corrosive attack mechanisms of those materials as well, viewing the optimization using of those materials for a more extended useful life.

  11. Summary of GOOSE Substation Communication

    Directory of Open Access Journals (Sweden)

    Xia Fei

    2015-01-01

    Full Text Available The fast real-time application message is an object-oriented substation event—GOOSE (Generic Object Oriented Substation Event. It mainly works on the process layers and bay layers of digital substation. GOOSE intelligent substation communication network can realize the key function of the overall intelligent sub-station functions. This paper will make a systematic analysis of GOOSE. At first, it will provide a detailed analysis of the transmission mechanism and process of GOOSE message. As certain practical operability lacks the actual application of the multicast filtering method which is applied to GOOSE message based on IEC61850 standard, this paper will summarize three message filtering methods, compare the advantages and disadvantages in topological networks of different kinds in accordance with the instantaneity of GOOSE intelligent substation communication network and draw a conclusion that the independent configuration scheme of GOOSE and SV can adapt to the requirement of times, so as to provide theoretical references for the selection of practical intelligent substation communication network in the future.

  12. Substation Reactive Power Regulation Strategy

    Science.gov (United States)

    Zhang, Junfeng; Zhang, Chunwang; Ma, Daqing

    2018-01-01

    With the increasing requirements on the power supply quality and reliability of distribution network, voltage and reactive power regulation of substations has become one of the indispensable ways to ensure voltage quality and reactive power balance and to improve the economy and reliability of distribution network. Therefore, it is a general concern of the current power workers and operators that what kind of flexible and effective control method should be used to adjust the on-load tap-changer (OLTC) transformer and shunt compensation capacitor in a substation to achieve reactive power balance in situ, improve voltage pass rate, increase power factor and reduce active power loss. In this paper, based on the traditional nine-zone diagram and combining with the characteristics of substation, a fuzzy variable-center nine-zone diagram control method is proposed and used to make a comprehensive regulation of substation voltage and reactive power. Through the calculation and simulation of the example, this method is proved to have satisfactorily reconciled the contradiction between reactive power and voltage in real-time control and achieved the basic goal of real-time control of the substation, providing a reference value to the practical application of the substation real-time control method.

  13. Correction: Large-scale electricity storage utilizing reversible solid oxide cells combined with underground storage of CO2 and CH4

    DEFF Research Database (Denmark)

    Jensen, Søren Højgaard; Graves, Christopher R.; Mogensen, Mogens Bjerg

    2017-01-01

    Correction for ‘Large-scale electricity storage utilizing reversible solid oxide cells combined with underground storage of CO2 and CH4’ by S. H. Jensen et al., Energy Environ. Sci., 2015, 8, 2471–2479.......Correction for ‘Large-scale electricity storage utilizing reversible solid oxide cells combined with underground storage of CO2 and CH4’ by S. H. Jensen et al., Energy Environ. Sci., 2015, 8, 2471–2479....

  14. Development of 12-Pulse Regulated Rectifier Circuit for Traction Substation

    Directory of Open Access Journals (Sweden)

    Sh. N. Nasirov

    2010-01-01

    Full Text Available The paper proposes a power circuit of a regulated 12-pulse direct current converter and a thyristor control impulse diagram for traction substations providing the best electric power supply of a rolling stock, train traction efficiency,  smooth direction regulation.

  15. Reliability 'H' scheme of HV/MV substations

    Directory of Open Access Journals (Sweden)

    Perić Dragoslav M.

    2015-01-01

    Full Text Available Substations (HV/MV connect transmission and distribution systems with consumers of electric energy. The selective search method was used for calculation of substation reliability, where all arrangement elements were grouped into blocks. Subject of the analysis was H-arrangements comprising air-insulated switchgears on the high voltage side of HV/MV substations with different number of feeder and transformer bays and diverse scope of the installed switching equipment. Failure rate and duration were used as main HV/MV substation equipment reliability indices. A large number of arrangements were classified into groups, and within a group the arrangements were ranked with the use of multiple criteria. It is shown that the reliability of the electricity transit depends on the equipment of field for the transit of electricity, which favors poorly equipped field. On the other hand, the reliability of transformation of the full power depends mostly on the equipment in coupling field. It is essential that in the coupling field, there are at least two disconnectors. Installation of the switch in the coupling field is meaningful only with appropriate protection, because it further improves reliability. Conclusions are drawn for phased construction and expansion of the single pole diagram with an additional field for the transmission line.

  16. Application of Electrical Resistivity Imaging and Land Surveying in the Analysis of Underground Construction Impact on the Warsaw Scarp

    Directory of Open Access Journals (Sweden)

    Kaczmarek Łukasz

    2016-12-01

    Full Text Available The paper presents the analysis of the II Underground Line construction’s impact on the Warsaw Scarp with the use of the electrical resistivity imaging (ERI, also known as the electrical resistivity tomography and further total station position measurements.The underground passes under the scarp perpendicular in the area of Dynasy Street 6, in Down-town district.The electrical resistivity imaging was performed for recognition of the geological structure and a potential land slide surface or zone.The gradient system was used during the prospection. In these analyses, the longitudinal section was 40 m long, and the depth of survey amounted to 6 m. In the case of the 200 m long transverse section, the resulted depth of survey was 30 m.The geophysical image of the longitudinal section,does not contain loosening soil zones,which could indicates lip surface.Next, total station measurements, which were tied to the archival geodetic observations’ results, were carried out. The aim of the measurements was to verify the activity of the horizontal and vertical displacements. The TBM excavation process led to summary vertical displacements up to approx. 24 mm and horizontal displacements amounting to approx. 13 mm. To sum up, the current land surveys reveals minor under ground line’ s construction impact on the scarp displacement. Nevertheless, the sensitive urban environment requires further monitoring, especially that the operation loads can result in displacement rate change.

  17. Canby Area Service Project : Substation and Associated Transmission Line : Environmental Assessment.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1992-02-01

    Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp's substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC's Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC's substation can accommodate only about 10 percent of the expected additional electric load. BPA's proposed action is intended to meet SVEC's increasing electric load. BPA proposes to meet SVEC's increasing energy load by tapping into BPA's existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC's Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no environmental impact statement'' is not required.

  18. Canby Area Service Project substation and associated transmission line. Environmental Assessment

    Energy Technology Data Exchange (ETDEWEB)

    1992-02-01

    Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp`s substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC`s Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC`s substation can accommodate only about 10 percent of the expected additional electric load. BPA`s proposed action is intended to meet SVEC`s increasing electric load. BPA proposes to meet SVEC`s increasing energy load by tapping into BPA`s existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC`s Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no ``environmental impact statement`` is not required.

  19. Offshore Substation Locating in Wind Farms Based on Prim Algorithm

    DEFF Research Database (Denmark)

    Hou, Peng; Hu, Weihao; Chen, Zhe

    2015-01-01

    The investment of offshore wind farm is large while the cost on electrical system can take up to 15% of the total costs. In order to reduce the cost, it is desirable to optimize the electrical system layout in design phase. Since the location of offshore substation (OS) is highly related to the e......The investment of offshore wind farm is large while the cost on electrical system can take up to 15% of the total costs. In order to reduce the cost, it is desirable to optimize the electrical system layout in design phase. Since the location of offshore substation (OS) is highly related...... with the cable connection layout. The results show that the proposed method is an effective way for offshore wind farm cable connection layout design....

  20. Major Refit for CERN's 400 kV Substation

    CERN Multimedia

    2001-01-01

    The 400 kV substation on the Prévessin site brings in the electricity that powers CERN's accelerators and the majority of the Laboratory's installations. It was originally built in the 1970s for the SPS, and is one of only five privately owned 400 kV sub-stations in France. Three of the others belong to the national railway company, SNCF, supplying the Paris-Marseilles TGV line, the other is at the Cadarache research centre near mouth of the Rhone. After nearly thirty years of service, CERN's substation has just undergone a complete overhaul. The new main 18 kV switchboard for the SPS pulsed network. The electricity supply for the original Prévessin substation was from the 400 kV EDF network, delivered through three 90 MW transformers at 18 kV to the SPS pulsed network, With the arrival of LEP, two 110 MW transformers were added to supply the new accelerator. Now, as CERN gears up for the LHC, additional pulsed power capacity is needed to supply the transfer lines carrying protons from...

  1. Future power plant control integrates process and substation automation into one system; Zukunftsorientierte Kraftwerksleittechnik vereint Prozess- und Stationsautomatisierung

    Energy Technology Data Exchange (ETDEWEB)

    Orth, J. [ABB AG, Mannheim (Germany). Div. Energietechnik-Systeme

    2007-07-01

    The new IEC 61850 standard has been established for substation control systems. In future, IEC 61850 may also be widely used for electrical systems in power plants. IEC 61850 simplifies the integration of process and substation control systems in power plants by creating one automated system across manufacturers and thus makes a significant contribution to cost efficiency in operation and maintenance. (orig.)

  2. LIFE MANAGEMENT OF ASSET FROM HIGH VOLTAGE SUBSTATION

    Directory of Open Access Journals (Sweden)

    Sorina COSTINAŞ

    2010-11-01

    Full Text Available Companies have to reinvent continuously their business model. Maintenance can play a key role in the long-term profitability of a company. In Romania, especially since the liberalization of the energy market, the electrical companies are forced to identify and coordinate a lot of processes and to promote competitivity. It is necessary to work safety and be environmentally responsible in order to achieve electrical substations obiectives. In this paper will be presented maintenance strategy (replacement, upgrade or repair and informational aspects of decisional process (technical, financial, social politic, legal and risk aspects. Proposed methodology regarding the maintenance of electrical substation will be focused in how to improve the decisions for improving asset maintenance performance through ISO 9001/14001.

  3. Experimental study of thermal field deriving from an underground electrical power cable buried in non-homogeneous soils

    International Nuclear Information System (INIS)

    Lieto Vollaro, Roberto de; Fontana, Lucia; Vallati, Andrea

    2014-01-01

    The electrical cables ampacity mainly depends on the cable system operation temperature. To achieve a better cable utilization and reduce the conservativeness typically employed in buried cable design, an accurate evaluation of the heat dissipation through the cables and the surrounding soil is important. In the traditional method adopted by the International Electrotechnical Commission (IEC) and the Institute of Electrical and Electronics Engineers (IEEE) for the computation of the thermal resistance between an existing underground cable system and the external environment, it is still assumed that the soil is homogeneous and has uniform thermal conductivity. Numerical studies have been conducted to predict the temperature distribution around the cable for various configurations and thermal properties of the soil. The paper presents an experimental study conducted on a scale model to investigate the heat transfer of a buried cable, with different geometrical configurations and thermal properties of the soil, and to validate a simplified model proposed by the authors in 2012 for the calculation of the thermal resistance between the underground pipe or electrical cable and the ground surface, in cases where the filling of the trench is filled with layers of materials with different thermal properties. Results show that experimental data are in good agreement with the numerical ones. -- Highlights: • Heat transfer of a buried cable has been experimentally studied on a scale model. • Different configurations and thermal properties of the soil have been tested. • Authors previously proposed a simplified model and obtained numerical results. • Experimental results and numerical ones previously obtained were in accordance

  4. Wolf Point Substation, Roosevelt County, Montana

    Energy Technology Data Exchange (ETDEWEB)

    1991-05-01

    The Western Area Power Administration (Western), an agency of the United States Department of Energy, is proposing to construct the 115-kV Wolf Point Substation near Wolf Point in Roosevelt County, Montana (Figure 1). As part of the construction project, Western's existing Wolf Point Substation would be taken out of service. The existing 115-kV Wolf Point Substation is located approximately 3 miles west of Wolf Point, Montana (Figure 2). The substation was constructed in 1949. The existing Wolf Point Substation serves as a Switching Station'' for the 115-kV transmission in the region. The need for substation improvements is based on operational and reliability issues. For this environmental assessment (EA), the environmental review of the proposed project took into account the removal of the old Wolf Point Substation, rerouting of the five Western lines and four lines from the Cooperatives and Montana-Dakota Utilities Company, and the new road into the proposed substation. Reference to the new proposed Wolf Point Substation in the EA includes these facilities as well as the old substation site. The environmental review looked at the impacts to all resource areas in the Wolf Point area. 7 refs., 6 figs.

  5. Wolf Point Substation, Roosevelt County, Montana

    International Nuclear Information System (INIS)

    1991-05-01

    The Western Area Power Administration (Western), an agency of the United States Department of Energy, is proposing to construct the 115-kV Wolf Point Substation near Wolf Point in Roosevelt County, Montana (Figure 1). As part of the construction project, Western's existing Wolf Point Substation would be taken out of service. The existing 115-kV Wolf Point Substation is located approximately 3 miles west of Wolf Point, Montana (Figure 2). The substation was constructed in 1949. The existing Wolf Point Substation serves as a ''Switching Station'' for the 115-kV transmission in the region. The need for substation improvements is based on operational and reliability issues. For this environmental assessment (EA), the environmental review of the proposed project took into account the removal of the old Wolf Point Substation, rerouting of the five Western lines and four lines from the Cooperatives and Montana-Dakota Utilities Company, and the new road into the proposed substation. Reference to the new proposed Wolf Point Substation in the EA includes these facilities as well as the old substation site. The environmental review looked at the impacts to all resource areas in the Wolf Point area. 7 refs., 6 figs

  6. 75 FR 43519 - Parker-Davis Project; Transmission Capacity for Renewable Energy Between Electrical District No...

    Science.gov (United States)

    2010-07-26

    ... for Renewable Energy Between Electrical District No. 5 Substation and the Palo Verde Hub AGENCY... approximately 1,700 miles of high-voltage transmission lines and the associated substations and switchyards. The... Western's substations in the vicinity of Electrical District No. 5 (ED-5) Substation near Eloy, Arizona...

  7. Rural electrification in Chihuahua, Mexico at one third of the cost vs a conventional substation

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez, Omar; Gomez, Rolando; Solano, Arturo; Acosta, Eduardo

    2010-09-15

    This paper and presentation describes technical details about a successful experience in a unique project in Mexico for making possible the rural electrification at one third of the total cost vs a traditional substation. This alternate solution for electrification of rural communities where construction of distribution lines or traditional substations are not economically possible due to local government's budget limits or because the electrical companies are looking for the ROI Return Over Investment in poverty communities.

  8. Integration of digital systems for substation control; Integracao de sistemas digitais para controle de subestacoes

    Energy Technology Data Exchange (ETDEWEB)

    Jardini, Jose Antonio; Magrini, Luiz Carlos; Kayano, Paula S.D.; Shinkai, Roberto; Nakamura, Arnaldo [Sao Paulo Univ., SP (Brazil). Escola Politecnica

    1998-12-01

    The Polytechnic School of Sao Paulo University, Brazil, developed a digital system for automation of substation from the integration of hardware and software modules available in the market using different protocols. This article describes a reduced prototype of this system in the substation which supplies electric power to the College Campus, presenting good results and demonstrating to be possible the assembly of really open system.

  9. Alternative surfacing materials for weed control at BC Hydro substations

    International Nuclear Information System (INIS)

    Wells, T.C.; Shrimpton, G.M.

    1997-01-01

    A two year study was conducted by BC Hydro in which a variety of surfacing materials were tested for their suitability for use in substations. Ideally, surfacing materials should have the following characteristics: high electrical resistivity in both dry and wet conditions, resistance to invasion by weeds, good driveability, good drainage, non-flammable, reasonably priced, no dust to foul conductors, and be aesthetically pleasing. Trials at Vernon Koksilah, and Ingledow substations were conducted to test the materials. A qualitative estimate of the amount of weed control provided by each material was recorded. The trials were meant to provide operational recommendations and screening information to allow for future testing of promising materials or combination of materials. Results showed that no single material meets all the desired criteria. The surfaces that best combined good weed control, electrical resistance and surface stability was a 15 cm deep layer of crushed gravel, especially if underlain by a layer of geotextile. 4 refs., 3 tabs., 1 fig

  10. Technical-parameter calculation model for underground low-power electrical lines and indoor installations used in telecommunications

    Directory of Open Access Journals (Sweden)

    Henry Bastidas Mora

    2011-09-01

    Full Text Available This article presents an analysis of electrical distribution theory for 60Hz-lines operating at low voltage, particularly underground lines and residential indoor installations. Such distribution lines’ behaviour is observed as a function of frequency to consider any advantages regarding the potential use of power transmission lines (PTL for transmitting telecommunication signals. A method for computing the secondary parameters is proposed which has been based on the primary parameters, namely inductance, capacitance, conductance and resistance. The secondary parameters so obtained were characteristic impedance, propagation constant (together with its real value and the attenuation constant. Conductor configurations, insulation materials and gauges commonly used in Colombia were verified for such low-voltage lines. A mathematical model is proposed as a theoretical tool for analysing and predicting characteristic impedance pattern and the attenuations which occur at high frequencies, thereby complementing our group’s previous work. Conclusions are drawn, together with a perspective regarding future work and applications.

  11. Automated system for load flow prediction in power substations using artificial neural networks

    Directory of Open Access Journals (Sweden)

    Arlys Michel Lastre Aleaga

    2015-09-01

    Full Text Available The load flow is of great importance in assisting the process of decision making and planning of generation, distribution and transmission of electricity. Ignorance of the values in this indicator, as well as their inappropriate prediction, difficult decision making and efficiency of the electricity service, and can cause undesirable situations such as; the on demand, overheating of the components that make up a substation, and incorrect planning processes electricity generation and distribution. Given the need for prediction of flow of electric charge of the substations in Ecuador this research proposes the concept for the development of an automated prediction system employing the use of Artificial Neural Networks.

  12. Influence of frequency-dependent soil electrical parameters on the evaluation of lightning electromagnetic fields in air and underground

    Science.gov (United States)

    Delfino, Federico; Procopio, Renato; Rossi, Mansueto; Rachidi, Farhad

    2009-06-01

    This paper is aimed at analyzing the influence of the frequency-dependent behavior of the ground electrical parameters (conductivity and ground permittivity) on the electromagnetic field radiated by a cloud-to-ground lightning return stroke. Both radiation in air (over the conducting ground plane) and underground are considered in the analysis. The adopted method is based on the classical Sommerfeld's theory and takes advantage of an efficient ad hoc numerical procedure to face with the slow converging Sommerfeld's integrals. This feature allows the electromagnetic field to be computed without any sort of mathematical approximation and, since it is carried out in the frequency domain, can be used either if the ground permittivity and conductivity are considered constant or if they vary with the working frequency with any functional law. Simulations have been performed to identify the cases in which the approximation of constant ground permittivity and conductivity leads to satisfactory results. It is shown that for soils with water contents of 2% to 10% (ground conductivities in the order of 0.001 to 0.01 S/m), the assumption of constant electrical parameters appears to be reasonable. However, for either very poorly conducting soils (10-4 S/m or so) or highly conducting soils (10-1 S/m), the electromagnetic field components appear to be significantly affected by the frequency dependence of the ground electrical parameters.

  13. El Paso Electric Company Diablo Substation to the US-Mexico border 115kV transmission line project. Final Environmental Assessment

    Energy Technology Data Exchange (ETDEWEB)

    1992-04-01

    This Environmental Assessment documents the analysis of alternative corridors for development and operation of a proposed 115 kilovolt transmission line using private lands and transporting power to the US-Mexico international border. The project will require (1) an amendment to El Paso Electric Company`s existing export authorization to transfer power across this border, and (2) a Presidential Permit for construction of the transmission line. The project would be located in Dona Ana county in southern New Mexico, approximately five miles west of El Paso, Texas. The alternative corridors, specific locations within those corridors, and structure types are identified and analyzed in the environmental studies.

  14. High Temperature Superconducting Underground Cable

    International Nuclear Information System (INIS)

    Farrell, Roger A.

    2010-01-01

    The purpose of this Project was to design, build, install and demonstrate the technical feasibility of an underground high temperature superconducting (HTS) power cable installed between two utility substations. In the first phase two HTS cables, 320 m and 30 m in length, were constructed using 1st generation BSCCO wire. The two 34.5 kV, 800 Arms, 48 MVA sections were connected together using a superconducting joint in an underground vault. In the second phase the 30 m BSCCO cable was replaced by one constructed with 2nd generation YBCO wire. 2nd generation wire is needed for commercialization because of inherent cost and performance benefits. Primary objectives of the Project were to build and operate an HTS cable system which demonstrates significant progress towards commercial progress and addresses real world utility concerns such as installation, maintenance, reliability and compatibility with the existing grid. Four key technical areas addressed were the HTS cable and terminations (where the cable connects to the grid), cryogenic refrigeration system, underground cable-to-cable joint (needed for replacement of cable sections) and cost-effective 2nd generation HTS wire. This was the worlds first installation and operation of an HTS cable underground, between two utility substations as well as the first to demonstrate a cable-to-cable joint, remote monitoring system and 2nd generation HTS.

  15. High Temperature Superconducting Underground Cable

    Energy Technology Data Exchange (ETDEWEB)

    Farrell, Roger, A.

    2010-02-28

    The purpose of this Project was to design, build, install and demonstrate the technical feasibility of an underground high temperature superconducting (HTS) power cable installed between two utility substations. In the first phase two HTS cables, 320 m and 30 m in length, were constructed using 1st generation BSCCO wire. The two 34.5 kV, 800 Arms, 48 MVA sections were connected together using a superconducting joint in an underground vault. In the second phase the 30 m BSCCO cable was replaced by one constructed with 2nd generation YBCO wire. 2nd generation wire is needed for commercialization because of inherent cost and performance benefits. Primary objectives of the Project were to build and operate an HTS cable system which demonstrates significant progress towards commercial progress and addresses real world utility concerns such as installation, maintenance, reliability and compatibility with the existing grid. Four key technical areas addressed were the HTS cable and terminations (where the cable connects to the grid), cryogenic refrigeration system, underground cable-to-cable joint (needed for replacement of cable sections) and cost-effective 2nd generation HTS wire. This was the world’s first installation and operation of an HTS cable underground, between two utility substations as well as the first to demonstrate a cable-to-cable joint, remote monitoring system and 2nd generation HTS.

  16. Development of Diagnostic Technology for Substation Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Kweon, D.J.; Yoon, J.Y. [Korea Electric Power Research Institute, Taejeon (Korea, Republic of)

    1998-09-01

    This report contains the conceptual design of predictive diagnostic system for KEPCO 765kV substation apparatus which will be operated in 2001. Various kinds of techniques in the world for power transformer and GIS monitoring were examined, then the integrated diagnosis system configuration which will be most effective in our future substation was suggested. In addition, the development of the optimum life management for substation facilities. development of a system to measure the ESDD of substation insulator surfaces at a distance and application study of the degradation sensor(PCS) were described also. (author) 55 refs., 27 figs., 68 tabs.

  17. Design of a grounding network in electrical substations. Materials and formulas the most used; Diseno de redes de tierra en subestaciones electricas. Materiales y formulas mas utilizadas

    Energy Technology Data Exchange (ETDEWEB)

    Raull Martin, J. [Facultad de Ingenieria, UNAM, Mexico, D.F. (Mexico)

    2000-09-01

    The purpose of this paper is to present a summarized version of the different types of construction of grounding systems, as well as their materials and formulas, which are necessary and useful for the design and building of a grounding network for medium to high voltage facilities. A description is also made of how to determine the electrical resistivity of subsoil layers with different physical characteristics. Several illustrative examples are also solved in the paper. [Spanish] El proposito de este articulo es presentar de manera resumida los diferentes tipos de construccion de los sistemas de tierra, asi como sus materiales y formulas, los cuales son necesarios y utiles para el diseno y edificacion de una red de tierra para instalaciones de mediana y alta tension. Se describe tambien la obtencion de las diferentes resistividades que presenta los terrenos con diversas caracteristicas fisicas. Asimismo, se solucionan ejercicios ilustrativos a lo largo del articulo.

  18. Comparisons process-to-bay level peer-to-peer network delay in IEC 61850 substation communication systems

    Directory of Open Access Journals (Sweden)

    Nasser Hasan Ali

    2014-12-01

    Full Text Available This paper presents the application of IEC 61850 protocol in electrical power engineering industry for data communication systems between substations. This IEC 61850 protocol presents new challenges for real-time communication performance between Intelligent Electronic Devices (IEDs within substation because of the Generic Object Oriented Substation Event (GOOSE messages. The analyses of substation Ethernet and WLAN (wireless LAN communication delay, its impact factors, various methods and different network topologies which can improve the real-time performance are discussed. For basic analysis of data flow within a substation, the Optimized Network Engineering Tool (OPNET software is used. The process-to-bay level network simulation model is performed by using the OPNET software. The Ethernet delay and WLAN peer-to-peer performance of the process-to-bay level network simulation results are analyzed which is based on AP (access point, switched, shared Ethernet network or peer-to-peer network.

  19. Metalclad substation subdivided into tight compartments

    Energy Technology Data Exchange (ETDEWEB)

    Diaferia, A.; Messie, M.

    1990-02-06

    This invention relates to a high voltage metalclad substation, having a metal enclosure, filled with a high dielectric strength gas, and subdivided into different compartments by tight insulating partitions. The object of this invention is to achieve a simplified substation of reduced dimensions preserving the possibilities of performing operations on part of the substation, while the other part remains live. According to the invention, a metalclad substation is provided, having a busbar isolating switch including an operating mechanism housed in the busbar compartment. The movable contacts of the isolating switch are housed in a compartment separated by a tight insulating partition from the busbar compartment. Tight partitioning of the compartments enables operations to be carried out in the different compartments while maintaining at least one of the busbars switched on to supply the unaffected part of the installation. The invention can be applied to a single-phase or a three-phase enclosure substation. 4 figs.

  20. ELF electromagnetic environment in power substations.

    Science.gov (United States)

    Hayashi, N; Isaka, K; Yokoi, Y

    1989-01-01

    This paper presents a theoretical analysis of electromagnetic environments in power substations in service. A new analytical method is developed and applied to magnetic field calculations in 187-kV and 66-kV substations. Experimental results verify that the method offers a good prediction of the magnetic field profiles in the substations except for the areas where localized field sources exist. The analytical results show that the magnetic field strength depends to a great extent on how the load powers distribute on individual lines and buses, that the magnetic fields in substations have a three-dimensional characteristic, and that the predominant field component depends on the position of interest. Moreover, it is suggested that objects placed in substations are exposed not only to magnetic fields of high strength in comparison to those in houses or near the distribution networks but also to fields with several percent of harmonic distortion.

  1. Offshore substation workers’ exposure to harmful factors – Actions minimizing risk of hazards

    Directory of Open Access Journals (Sweden)

    Paweł Janusz Piotrowski

    2016-02-01

    Full Text Available The current development of electric power industry in Poland, especially in the field of renewable energy sources, including wind power, brings about the need to introduce legislation on new work environment. The development of occupational safety and health (OSH regulations that must be met by new workplaces, such as offshore substations becomes necessary in view of the construction of modern offshore wind power plants – offshore wind farms. Staying on offshore substation is associated with an increased exposure to harmful health factors: physical, chemical, biological and psychophysical. The main sources of health risks on offshore substations are: temperature, electromagnetic field, noise from operating wind turbines, direct and alternating current, chemicals, Legionella bacteria and social isolation of people. The aim of this article is to draw attention to the problem of offshore substation workers’ exposure to harmful factors and to present methods of preventing and reducing the risk-related adverse health effects. In this paper, there are identified and described risks occurring on offshore substations (fire, explosion, lightning, accidents at work. Some examples of the means and the methods for reducing the negative impact of exposure on the human health are presented and discussed. The article also highlights the need to develop appropriate laws and health and safety regulations concerning the new working environment at the offshore substations. The review of researches and international standards shows that some of them can be introduced into the Polish labor market. Med Pr 2016;67(1:51–72

  2. Detection of leaks in underground storage tanks using electrical resistance methods: 1996 results

    International Nuclear Information System (INIS)

    Ramirez, A.; Daily, W.

    1996-10-01

    This document provides a summary of a field experiment performed under a 15m diameter steel tank mockup located at the Hanford Reservation, Washington. The purpose of this test was to image a contaminant plume as it develops in soil under a tank already contaminated by previous leakage and to determine whether contaminant plumes can be detected without the benefit of background data. Measurements of electrical resistance were made before and during a salt water release. These measurements were made in soil which contained the remnants of salt water plumes released during previous tests in 1994 and in 1995. About 11,150 liters of saline solution were released along a portion of the tank's edge in 1996. Changes in electrical resistivity due to release of salt water conducted in 1996 were determined in two ways: (1) changes relative to the 1996 pre-spill data, and (2) changes relative to data collected near the middle of the 1996 spill after the release flow rate was increased. In both cases, the observed resistivity changes show clearly defined anomalies caused by the salt water release. These results indicate that when a plume develops over an existing plume and in a geologic environment similar to the test site environment, the resulting resistivity changes are easily detectable. Three dimensional tomographs of the resistivity of the soil under the tank show that the salt water release caused a region of low soil resistivity which can be observed directly without the benefit of comparing the tomograph to tomographs or data collected before the spill started. This means that it may be possible to infer the presence of pre-existing plumes if there is other data showing that the regions of low resistivity are correlated with the presence of contaminated soil. However, this approach does not appear reliable in defining the total extent of the plume due to the confounding effect that natural heterogeneity has on our ability to define the margins of the anomaly

  3. Insulation coordination workstation for AC and DC substations

    International Nuclear Information System (INIS)

    Booth, R.R.; Hileman, A.R.

    1990-01-01

    The Insulation Coordination Workstation was designed to aid the substation design engineer in the insulation coordination process. The workstation utilizes state of the art computer technology to present a set of tools necessary for substation insulation coordination, and to support the decision making process for all aspects of insulation coordination. The workstation is currently being developed for personal computers supporting OS/2 Presentation Manager. Modern Computer-Aided Software Engineering (CASE) technology was utilized to create an easily expandable framework which currently consists of four modules, each accessing a central application database. The heart of the workstation is a library of user-friendly application programs for the calculation of important voltage stresses used for the evaluation of insulation coordination. The Oneline Diagram is a graphic interface for data entry into the EPRI distributed EMTP program, which allows the creation of complex systems on the CRT screen using simple mouse clicks and keyboard entries. Station shielding is graphically represented in the Geographic Viewport using a three-dimensional substation model, and the interactive plotting package allows plotting of EPRI EMTP output results on the CRT screen, printer, or pen plotter. The Insulation Coordination Workstation was designed by Advanced Systems Technology (AST), a division of ABB Power Systems, Inc., and sponsored by the Electric Power Research Institute under RP 2323-5, AC/DC Insulation Coordination Workstation

  4. Integration of three-dimensional modelling, scientific visualization and virtual reality applied to electric power substations; Integracao de modelagem tridimensional, visualizacao cientifica e realidade virtual com aplicacao em subestacoes de energia eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Buriol, Tiago Martinuzzi; Scheer, Sergio [Universidade Federal do Parana (UFPR), Curitiba, PR (Brazil). Centro de Estudos de Engenharia Civil]. E-mails: tiagoburiol@gmail.com; scheer@ufpr.br

    2007-04-15

    The Virtual Reality technology (VR) is considered the most advanced human/computer interface ever known, with applications in several fields of science and engineering. In the energy sector, research has been carried out aiming at applying this technology in planning, training and simulation activities. In this work a few possible VR applications related to power substations are presented. Aspects of modelling, navigation, and scientific visualization are addressed. In addition, an application for the visualization of illuminance fields is presented. (author)

  5. Environmental impact of high voltage substations

    International Nuclear Information System (INIS)

    Geambasu, C.; Popadiuc, S.; Drobota, C.; Marza, F.

    2004-01-01

    The first Romanian methodology for simultaneous environmental and human risk evaluation in case of HV installations within substations pertaining to nuclear power stations, based on EU regulation is now applicable in Cernavoda substation. High voltage substations are zones where the environmental impact is focused on electromagnetic field that's causes particular effects in living tissues (human being included). That is the reason why is necessary to identify the potential risk sources, the asses including the way to correct them and to dissimulate the results to the staff and the operational personal.(author)

  6. Substation design improvement with a probabilistic reliability approach using the TOPASE program

    Energy Technology Data Exchange (ETDEWEB)

    Bulot, M.; Heroin, G.; Bergerot, J-L.; Le Du, M. [Electricite de France (France)

    1997-12-31

    TOPASE, (the French acronym for Probabilistic Tools and Data Processing for the Analysis of Electric Systems), developed by Electricite de France (EDF) to perform reliability studies on transmission substations, was described. TOPASE serves a dual objective of assisting in the automation of HV substation studies, as well as enabling electrical systems experts who are not necessarily specialists in reliability studies to perform such studies. The program is capable of quantifying the occurrence rate of undesirable events and of identifying critical equipment and the main incident scenarios. The program can be used to improve an existing substation, to choose an HV structure during the design stage, or to choose a system of protective devices. Data collected during 1996 and 1997 will be analyzed to identify useful experiences and to validate the basic concepts of the program. 4 figs.

  7. Life cycle assessment of the Danish electricity distribution network

    DEFF Research Database (Denmark)

    Turconi, Roberto; Simonsen, Christian G.; Byriel, Inger P.

    2014-01-01

    Purpose This article provides life cycle inventory data for electricity distribution networks and a life cycle assessment (LCA) of the Danish transmission and distribution networks. The aim of the study was to evaluate the potential importance of environmental impacts associated with distribution......, in current and future electricity systems. Methods The functional unit was delivery of 1 kWh of electricity in Denmark. The focus of the assessment was distribution of electricity, and the related impacts were compared to the generation and transmission of electricity, in order to evaluate the importance...... of electricity distribution in Denmark. The 2010 Danish electricity distribution network was modeled, including power lines (50, 10, 0.4 kV), transformers (50/10 and 10/0.4 kV), and relevant auxiliary infrastructure (e.g., cable ditches, poles, and substations). Two types of 50 kV power lines (underground...

  8. Uncertainty models applied to the substation planning

    Energy Technology Data Exchange (ETDEWEB)

    Fontoura Filho, Roberto N. [ELETROBRAS, Rio de Janeiro, RJ (Brazil); Aires, Joao Carlos O.; Tortelly, Debora L.S. [Light Servicos de Eletricidade S.A., Rio de Janeiro, RJ (Brazil)

    1994-12-31

    The selection of the reinforcements for a power system expansion becomes a difficult task on an environment of uncertainties. These uncertainties can be classified according to their sources as exogenous and endogenous. The first one is associated to the elements of the generation, transmission and distribution systems. The exogenous uncertainly is associated to external aspects, as the financial resources, the time spent to build the installations, the equipment price and the load level. The load uncertainly is extremely sensible to the behaviour of the economic conditions. Although the impossibility to take out completely the uncertainty , the endogenous one can be convenient treated and the exogenous uncertainly can be compensated. This paper describes an uncertainty treatment methodology and a practical application to a group of substations belonging to LIGHT company, the Rio de Janeiro electric utility. The equipment performance uncertainty is treated by adopting a probabilistic approach. The uncertainly associated to the load increase is considered by using technical analysis of scenarios and choice criteria based on the Decision Theory. On this paper it was used the Savage Method and the Fuzzy Set Method, in order to select the best middle term reinforcements plan. (author) 7 refs., 4 figs., 6 tabs.

  9. Directional sound radiation from substation transformers

    International Nuclear Information System (INIS)

    Maybee, N.

    2009-01-01

    This paper presented the results of a study in which acoustical measurements at two substations were analyzed to investigate the directional behaviour of typical arrays having 2 or 3 transformers. Substation transformers produce a characteristic humming sound that is caused primarily by vibration of the core at twice the frequency of the power supply. The humming noise radiates predominantly from the tank enclosing the core. The main components of the sound are harmonics of 120 Hz. Sound pressure level data were obtained for various directions and distances from the arrays, ranging from 0.5 m to over 100 m. The measured sound pressure levels of the transformer tones displayed substantial positive and negative excursions from the calculated average values for many distances and directions. The results support the concept that the directional effects are associated with constructive and destructive interference of tonal sound waves emanating from different parts of the array. Significant variations in the directional sound pattern can occur in the near field of a single transformer or an array, and the extent of the near field is significantly larger than the scale of the array. Based on typical dimensions for substation sites, the distance to the far field may be much beyond the substation boundary and beyond typical setbacks to the closest dwellings. As such, the directional sound radiation produced by transformer arrays introduces additional uncertainty in the prediction of substation sound levels at dwellings within a few hundred meters of a substation site. 4 refs., 4 figs.

  10. Augmented Reality Applications for Substation Management by Utilizing Standards-Compliant SCADA Communication

    Directory of Open Access Journals (Sweden)

    Miro Antonijević

    2018-03-01

    Full Text Available Most electrical substations are remotely monitored and controlled by using Supervisory Control and Data Acquisition (SCADA applications. Current SCADA systems have been significantly enhanced by utilizing standardized communication protocols and the most prominent is the IEC 61850 international standard. These enhancements enable improvements in different domains of SCADA systems such as communication engineering, data management and visualization of automation process data in SCADA applications. Process data visualization is usually achieved through Human Machine Interface (HMI screens in substation control centres. However, this visualization method sometimes makes supervision, control and maintenance procedures executed by engineers slow and error-prone because it separates equipment from its automation data. Augmented reality (AR and mixed reality (MR visualization techniques have matured enough to provide new possibilities of displaying relevant data wherever needed. This paper presents a novel methodology for visualizing process related SCADA data to enhance and facilitate human-centric activities in substations such as regular equipment maintenance. The proposed solution utilizes AR visualization techniques together with standards-based communication protocols used in substations. The developed proof-of-concept AR application that enables displaying SCADA data on the corresponding substation equipment with the help of AR markers demonstrates originality and benefits of the proposed visualization method. Additionally, the application enables displaying widgets and 3D models of substation equipment to make the visualization more user-friendly and intuitive. The visualized SCADA data needs to be refreshed considering soft real-time data delivery restrictions. Therefore, the proposed solution is thoroughly tested to demonstrate the applicability of proposed methodology in real substations.

  11. A Heuristic Method for the Reduction of the Outage Rate of High-Voltage Substations Due to Atmospheric Overvoltages

    Directory of Open Access Journals (Sweden)

    Christos A. Christodoulou

    2018-02-01

    Full Text Available The adequate protection against lightning surges and the limitation of the expected annual failure rate of high-voltage substations are critical issues, in an effort to secure the safety of the equipment and the personnel. Various factors affect the lightning performance of the substations, determining the developed lightning surges and the expected outage rate, i.e., the grounding resistance, the length of the underground cable between the connected overhead transmission line and the power transformer, and the installation position of the arresters. In the current work, a heuristic method is developed to adjust different parameters of high-voltage substations that upgrade their lightning performance. The proposed methodology can be useful to the studies of substations’ designers and engineers, contributing effectively in the reduction or/and elimination of lightning failures.

  12. Analysis of Norm IEC 61850 in the transmission of data via communications network of substations

    Energy Technology Data Exchange (ETDEWEB)

    Renda, T.; Botura Junior, G. [Universidade Estadual Paulista (UNESP), Sorocaba, SP (Brazil); Mesquita, L.; Rizol, P.M.S.R. [Universidade Estadual Paulista (UNESP), Guaratingueta, SP (Brazil)

    2009-07-01

    The tendency of using a protocol allows electrical substations to become 'intelligent', that is, capable of communicating in a much more efficient manner. This greatly reduces the number of connections, and as a consequence optimizes the speed between messages. The Norm IEC 61850-9-2 came to minimize the use of cables for the interconnections of various equipment involved in safety procedures of a substation. The present paper, has the objective of identifying a way of integrating the Norm IEC-61850 with the transmission of data via 'Generic Object Oriented Substation Event' (GOOSE) and of substituting the direct connection of binary I/O's of the Intelligent Electronic Devices also known as IED's. (author)

  13. Renewal work for the substation of the Transportation Bureau of the Osaka City; Osakashi kotsukyoku hendensho no koshin koji

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-01-10

    Fuji Electric Co. delivered various kinds of power receiving/transforming equipment for the renewal of the equipment of various substations (Higashi-Mikuni, Tanimachi 4-chome, Tanimachi 9-chome) of the Transportation Bureau of the Osaka City. The main equipment is as follows at each substation. 24kV cubicle type gas insulation switch (C-GIS), transformer for rectifier, silicon rectifier, d.c. 750V and 7.2kV enclosed switchboard, main control use switchboard, etc. The main characteristics are as follows: 1) The ground substation was made incombustible by adopting the gas insulation transformer. 2) Economic measures against high frequency are taken for the rectifier by adopting the equivalent 12 pulse method in which a reactor is inserted into No.1 bank. 3) As measures against the failure of power regenerative braking of running vehicles, the GTO chopper type regenerative power absorber is adopted (Higashi-Mikuni Substation). (NEDO)

  14. Availability analysis of high voltage substations considering its main equipment; Analise de disponibilidade de subestacoes de alta tensao considerando seus principais equipamentos

    Energy Technology Data Exchange (ETDEWEB)

    Santos, R.C. [Universidade Federal do ABC (UFABC), Santo Andre, SP (Brazil)], E-mail: ricardo.santos@ufabc.edu.br; Basseto, B.A.; Cugnasca, P.S.; Almeida Junior, J.R.; Camargo Junior, J.B. [Universidade de Sao Paulo (USP), SP (Brazil). Escola Politecnica], Emails: ricardo.santos@ufabc.edu.br, joao.camargo@poli.usp.br

    2009-07-01

    This paper evaluates the availability of electric power substations, based on Monte Carlo simulation and Fault Tree Analysis, which can be used in a larger way, considering various scenarios, usually founded. The main fallouts modes considered in the availability analysis of power systems, as well as the main methods applied to reach this goal are discussed. The availability indexes of the Monte Carlos simulation are sufficient to indicate the critical points of the power system, and to make comparisons between different substations, related to the performance levels. Through these indexes it is possible to evaluate the impact of a switching action in a determined substation. For this, the substation studied indexes are compared before and after the switching action be considered to the substation in reference.

  15. Electric power underground distribution at the campus of the Sao Paulo university - project, installation and operation; Distribuicao subterranea no campus da Cidade Universitaria da USP - projeto, instalacao e operacao

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Kleber; Bussolini, Miguel [Sao Paulo Univ., SP (Brazil)

    1999-07-01

    This paper describes the new electric power distribution system at the main campus of the University of Sao Paulo - Brazil. This system aims to attain a high level of reliability in the electric power supply, with costs less than the present underground system.

  16. Going underground

    Energy Technology Data Exchange (ETDEWEB)

    Winqvist, T.; Mellgren, K.-E. (eds.)

    1988-01-01

    Contains over 100 short articles on underground structures and tunneling based largely on Swedish experience. Includes papers on underground workers - attitudes and prejudices, health investigations, the importance of daylight, claustrophobia; excavation, drilling and blasting; hydroelectric power plants; radioactive waste disposal; district heating; oil storage; and coal storage.

  17. Towards the Smart Grid: Substation Automation Architecture and Technologies

    Directory of Open Access Journals (Sweden)

    A. Leonardi

    2014-01-01

    Full Text Available This paper deals with Industrial Control Systems (ICS of the electrical sector and especially on the Smart Grid. This sector has been particularly active at establishing new standards to improve interoperability between all sector players, driven by the liberalization of the market and the introduction of distributed generation of energy. The paper provides a state-of-the-art analysis on architectures, technologies, communication protocols, applications, and information standards mainly focusing on substation automation in the transmission and distribution domain. The analysis shows that there is tremendous effort from the Smart Grid key stakeholders to improve interoperability across the different components managing an electrical grid, from field processes to market exchanges, allowing the information flowing more and more freely across applications and domains and creating opportunity for new applications that are not any more constraint to a single domain.

  18. [Offshore substation workers' exposure to harmful factors - Actions minimizing risk of hazards].

    Science.gov (United States)

    Piotrowski, Paweł Janusz; Robak, Sylwester; Polewaczyk, Mateusz Maksymilian; Raczkowski, Robert

    2016-01-01

    The current development of electric power industry in Poland, especially in the field of renewable energy sources, including wind power, brings about the need to introduce legislation on new work environment. The development of occupational safety and health (OSH) regulations that must be met by new workplaces, such as offshore substations becomes necessary in view of the construction of modern offshore wind power plants - offshore wind farms. Staying on offshore substation is associated with an increased exposure to harmful health factors: physical, chemical, biological and psychophysical. The main sources of health risks on offshore substations are: temperature, electromagnetic field, noise from operating wind turbines, direct and alternating current, chemicals, Legionella bacteria and social isolation of people. The aim of this article is to draw attention to the problem of offshore substation workers' exposure to harmful factors and to present methods of preventing and reducing the risk-related adverse health effects. In this paper, there are identified and described risks occurring on offshore substations (fire, explosion, lightning, accidents at work). Some examples of the means and the methods for reducing the negative impact of exposure on the human health are presented and discussed. The article also highlights the need to develop appropriate laws and health and safety regulations concerning the new working environment at the offshore substations. The review of researches and international standards shows that some of them can be introduced into the Polish labor market. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  19. Restoration of electric power system from the damage caused by the Hanshin-Awaji earthquake; Hanshin Awaji daishinsai to denryoku system

    Energy Technology Data Exchange (ETDEWEB)

    Kanayama, S. [Kansai Electric Power Co. Inc., Osaka (Japan)

    1996-05-30

    This paper summarizes the damage of electric power system by the Great Hanshin-Awaji Earthquake. Damages were occurred at ten power stations among 21 thermal power stations. At two power stations, damages in tanks were occurred by the liquefaction. There were damages in 181 facilities at 50 substations. There was occurred outage in 65 facilities at 17 substations. Twenty-three lines of aerial transmission facilities suffered from the earthquake. There were occurred damages in 20 steel towers at 12 lines. One of them was collapsed and the others were slightly damaged by the unequal displacement, which did not cause the outage. 102 lines of underground transmission facilities suffered from the earthquake. Outage happened at three lines with poor flexibility. Damages were occurred in 660 lines of distribution facilities. There were no dropping accidents of transformers. Although outage happened at 189 substations by the damages of facilities immediately after the earthquake, all of substations were restored up to 8:00 am next morning, to be able to supply electric power. It was considered that the functions of multiplex and multi-root facilities for transmission and transformation were secured.

  20. Environmental methodology for substation site selection

    International Nuclear Information System (INIS)

    Lamothe, P.

    1990-01-01

    In Quebec, distribution substations from 120/25 kV to 230/25 kV are subject to provincial government approval upon presentation of an environmental impact assessment. Lower voltage substations are subjected to an internal environmental assessment only, but the content in many cases is as elaborate as for higher voltage. For 315/25 kV substations, Hydro-Quebec must submit to Environment Quebec a Renseignement generaux (general information) document outlining the justification and characteristics of the project. It also includes a demarcation of the study area, the environmental approach and a calendar of the different stages of the project. Through an interdepartmental committee, the government provides Hydro-Quebec with guidelines on how to conduct the impact assessment, usually concerning the planning process, technical aspects, public consultation, and environmental aspects. Details are presented of the environmental methodology used by Hydro-Quebec for 120-230 kV substation site selection. This includes study area demarcation, preliminary public information, inventory of environmental and technical elements, ranking of inventory elements, expected impacts, value of elements, degree of environmental resistance, degree of technical and economic resistance, preliminary site selection, public consultation, site analysis, and corrective measures

  1. The San Bernabe power substation; La subestacion San Bernabe

    Energy Technology Data Exchange (ETDEWEB)

    Chavez Sanudo, Andres D. [Luz y Fuerza del Centro, Mexico, D. F. (Mexico)

    1997-12-31

    The first planning studies that gave rise to the San Bernabe substation go back to year 1985. The main circumstance that supports this decision is the gradual restriction for electric power generation that has been suffering the Miguel Aleman Hydro System, until its complete disappearance, to give priority to the potable water supply through the Cutzamala pumping system, that feeds in an important way Mexico City and the State of Mexico. In this document the author describes the construction project of the San Bernabe Substation; mention is made of the technological experiences obtained during the construction and its geographical location is shown, as well as the one line diagram of the same [Espanol] Los primeros estudios de planeacion que dieron origen a la subestacion San Bernabe se remontan al ano de 1985. La circunstancia principal que soporta esta decision es la restriccion paulatina para generar energia que ha venido experimentando el Sistema Hidroelectrico Miguel Aleman, hasta su desaparicion total, para dar prioridad al suministro de agua potable por medio del sistema de bombeo Cutzamala, que alimenta en forma importante a la Ciudad de Mexico y al Estado de Mexico. En este documento el autor describe el proyecto de construccion de la subestacion San Bernabe; se mencionan las experiencias tecnologicas obtenidas durante su construccion y se ilustra su ubicacion geografica, asi como un diagrama unifilar de la misma

  2. Dynamic Underground Stripping Project

    International Nuclear Information System (INIS)

    Aines, R.; Newmark, R.; McConachie, W.; Udell, K.; Rice, D.; Ramirez, A.; Siegel, W.; Buettner, M.; Daily, W.; Krauter, P.; Folsom, E.; Boegel, A.J.; Bishop, D.; Udell, K.

    1992-01-01

    LLNL is collaborating with the UC Berkeley College of Engineering to develop and demonstrate a system of thermal remediation and underground imaging techniques for use in rapid cleanup of localized underground spills. Called ''Dynamic Stripping'' to reflect the rapid and controllable nature of the process, it will combine steam injection, direct electrical heating, and tomographic geophysical imaging in a cleanup of the LLNL gasoline spill. In the first 8 months of the project, a Clean Site engineering test was conducted to prove the field application of the techniques before moving the contaminated site in FY 92

  3. Real business of electrical skill

    International Nuclear Information System (INIS)

    1981-03-01

    This book introduces electrical structure and duty of electric security officials with definition, kinds, safe system for electrical structure and position, mission, duty, license and revocation of one's license of officials. It also deals with plan for non utility electric installation such as condition control, the cost of materials and the cost of construction, important equipment and materials, supervisory control, design on non utility power substation, construction of non utility power substation, high voltage substation by cubicle interior wiring, utilization equipment, communication installation and safe work and safe education of electricity and related regulations.

  4. Major Refit for CERN's 400 kV Substation (Part of the new control and protection system for the 18 kV side)

    CERN Multimedia

    2001-01-01

    The 400 kV substation on the Prévessin site brings in the electricity that powers CERN's accelerators and the majority of the Laboratory's installations. It was originally built in the 1970s for the SPS, and is one of only five privately owned 400 kV sub-stations in France. Three of the others belong to the national railway company, SNCF, supplying the Paris-Marseilles TGV line, the other is at the Cadarache research centre near mouth of the Rhone. After nearly thirty years of service, CERN's substation has just undergone a complete overhaul.

  5. The evolution of the Luz y Fuerza del Centro substations. Volume 2; Evolucion de las subestaciones de Luz y Fuerza del Centro. Volumen 2

    Energy Technology Data Exchange (ETDEWEB)

    Carranza Ramirez, Sergio [Luz y Fuerza del Centro, Mexico, D. F. (Mexico)

    1997-12-31

    This document cites historical background of how the Luz y Fuerza del Centro substations have evolved up to nowadays. A brief description is made of one electric substation, the substation design criteria are mentioned, since it must comply with the requirements of reliability, service continuity, service quality, economy, geographical location, just for mentioning some of them. The more utilized arrangements of the Luz y Fuerza del Centro substations are described. In the same manner, the remote control substations are described mentioning the main elements of this type of substations. Mention is made also of the technological incorporations that have been made to the substations and the perspectives there are from these. One line diagrams of the electric substations are shown, as well as from power plant substations [Espanol] Este documento cita antecedentes historicos de como han evolucionando las subestaciones de Luz y Fuerza del Centro hasta hoy en dia. Se realiza una breve descripcion de una subestacion electrica, se mencionan los criterios de diseno de una subestacion, ya que debe cumplir con los requisitos de confiabilidad, continuidad, calidad del servicio, economia, situacion geografica, por mencionar algunos de estos. Se describen los arreglos de las subestaciones mas utilizados por Luz y Fuerza del Centro. De igual manera se describen las subestaciones telecontroladas mencionando los principales elementos de este tipo de subestaciones. Se mencionan las incorporaciones tecnologicas que se han realizado a las subestaciones y las perspectivas que se tienen de estas. Se muestran diagramas unifilares de subestaciones electricas, al igual que se muestran las plantas de las subestaciones

  6. Voltage Sags Matching to Locate Faults for Underground Distribution Networks

    Directory of Open Access Journals (Sweden)

    BAKAR, A. H. A.

    2011-05-01

    Full Text Available A voltage sags matching to locate a fault for underground distribution network is presented in this paper. Firstly the method identifies the faulted section by matching a voltage sags measured at the primary substation during a fault with pre-developed voltage sag database. From the identified faulted section, the distance of a fault from sending-end is calculated. The problem of multiple sections is addressed by ranking approach. Test results on an underground distribution network shows most faults can be located by the first attempt within high accuracy distance. Only few faulted sections found by the second attempt. Since the method is using only voltage sag data, monitored at the primary substation, the method is considers economical to be implemented for a rural distribution network.

  7. Utilization of gamagraphy in shielded substation

    International Nuclear Information System (INIS)

    Franca, W.J.; Pereira, M.J.

    1987-01-01

    The radiographic inspection using gamma rays applied to the bars/ insulating cones conenctions in SF6 gas-insulated transmission lines to idetify the bars which its lenghts could cause a failure, without disassembling, is presented. Using gamma rays radiography it was possible to correct the lenght of the bars found out the permissible tolerances with substantial reduction of the servicing time and consequently increase of the substation reliability. (author) [pt

  8. METHODOLOGY OF DETERMINATION OF QUALITY INDEX OF MAINTENANCE SERVICE SYSTEM OF POWER EQUIPMENT OF TRACTION SUBSTATIONS

    Directory of Open Access Journals (Sweden)

    O.O. Matusevych

    2016-03-01

    Full Text Available Purpose. The purpose of this paper is development of methodology for definition of a quality system of maintenance and repair (M and P power equipment of traction substations (TS of electrified railways operating under conditions of uncertainty based on expert information. Methodology. The basic tenets of the theory of fuzzy sets and marks, linguistic and interval estimates of experts were applied to solve this problem. Results. Analysis of the existing diversity of approaches to development of modern methods of improvement of M and P allows us to conclude that the improvement in the quality of the system is achieved by solving individual problems increase the operational reliability of power equipment of traction substations in the following main interrelated areas. There are technical, economic and organizational. The basis of the quality evaluation system is initial data and expertise developed version of the document formalized quality evaluation of electrical equipment of traction substations by experts. The choice of determining the level of Quality service system based on the marks, linguistic and interval estimates of experts, which are reflected in quantitative and / or qualitative form was done. The possible options for expert data presentation and their corresponding quantitative methods of calculating the integral index of quality improvement system maintenance and P of traction substations were described. The methodology and the method of assessing the quality of system maintenance and P of TS allows quickly respond to changing operating conditions of power equipment of traction substations, and to determine the most effective strategies for maintenance of electrical and P TS under conditions of uncertainty functioning distance electricity. Originality. The method of a systematic approach to improve the quality of the system maintenance and P of power equipment of traction substation under conditions of uncertainty based on expert

  9. Marys Lake 69/115-kV transmission line upgrade and substation expansion projects

    International Nuclear Information System (INIS)

    1996-05-01

    Western Area Power Administration (Western) and the Platte River Power Authority (Platte River) propose to upgrade portions of the existing electric transmission and substation system that serves the Town of Estes Park, Colorado. The existing transmission lines between the Estes Power Plant Switchyard and the Marys Lake Substation include a 115,000 volt (115-kV) line and 69,000 volt (69-kV) line. Approximately one mile is a double-circuit 115/69-kV line on steel lattice structures, and approximately two miles consists of separate single-circuit 115-kV and a 69-kV lines, constructed on wood H-Frame structures. Both lines were constructed in 1951 by the US Bureau of Reclamation. The existing transmission lines are on rights-of-way (ROW) that vary from 75 feet to 120 feet and are owned by Western. There are 48 landowners adjacent to the existing ROW. All of the houses were built adjacent to the existing ROW after the transmission lines were constructed. Upgrading the existing 69-kV transmission line between the Marys Lake Substation and the Estes Power Plant Switchyard to 115-kV and expanding the Marys Lake Substation was identified as the most effective way in which to improve electric service to Estes Park. The primary purpose and need of the proposed project is to improve the reliability of electric service to the Town of Estes Park. Lack of reliability has been a historical concern, and reliability will always be less than desired until physical improvements are made to the electrical facilities serving Estes Park

  10. Marys Lake 69/115-kV transmission line upgrade and substation expansion projects

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-01

    Western Area Power Administration (Western) and the Platte River Power Authority (Platte River) propose to upgrade portions of the existing electric transmission and substation system that serves the Town of Estes Park, Colorado. The existing transmission lines between the Estes Power Plant Switchyard and the Marys Lake Substation include a 115,000 volt (115-kV) line and 69,000 volt (69-kV) line. Approximately one mile is a double-circuit 115/69-kV line on steel lattice structures, and approximately two miles consists of separate single-circuit 115-kV and a 69-kV lines, constructed on wood H-Frame structures. Both lines were constructed in 1951 by the US Bureau of Reclamation. The existing transmission lines are on rights-of-way (ROW) that vary from 75 feet to 120 feet and are owned by Western. There are 48 landowners adjacent to the existing ROW. All of the houses were built adjacent to the existing ROW after the transmission lines were constructed. Upgrading the existing 69-kV transmission line between the Marys Lake Substation and the Estes Power Plant Switchyard to 115-kV and expanding the Marys Lake Substation was identified as the most effective way in which to improve electric service to Estes Park. The primary purpose and need of the proposed project is to improve the reliability of electric service to the Town of Estes Park. Lack of reliability has been a historical concern, and reliability will always be less than desired until physical improvements are made to the electrical facilities serving Estes Park.

  11. Knowledge engineering tool for training power-substation operators

    Energy Technology Data Exchange (ETDEWEB)

    Lambert-Torres, G. [Escola Federal de Engenharia de Itajuba (Brazil)]|[Univ. of Waterloo, Ontario (Canada); Costa, C.I.A.; Alves da Silva, A.P. [Escola Federal de Engeharia de Itajuba (Brazil); Ribeiro, G.M. [Companhia Energetica de Minas Gerais (Brazil); Quintana, V.H. [Univ. of Waterloo, Ontario (Canada)

    1997-04-01

    Artificial intelligence techniques have been applied to create systems that can give answers for different situations and assistance during the substation switching operation. These techniques have also been used for training purposes. This paper presents a computational package for training power substation operators in the control and corrective actions using expert system techniques. Illustrative examples are presented using a 138-kV CEMIG substation.

  12. Optimize awareness of hazards in underground coal mines caused by electrical ignitions and fires through appropriate training guidelines.

    CSIR Research Space (South Africa)

    Page, TPT

    1998-03-01

    Full Text Available technical requirements and suggestions for appropriate training methodologies for each category of staff that could influence the likelihood of electrical ignitions and fires occurring, are contained....

  13. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-96) - Snohomish District Substations

    Energy Technology Data Exchange (ETDEWEB)

    Hermeston, Mark W. [Bonneville Power Administration (BPA), Portland, OR (United States)

    2002-07-19

    Proposed Action: Vegetation Management for facilities located in the Snohomish District. BPA proposes total vegetation management (bareground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Snohomish District of the Snohomish Region.

  14. The use of HANDIDET reg-sign non-electric detonator assemblies to reduce blast-induced overpressure at AECL's Underground Research Laboratory

    International Nuclear Information System (INIS)

    Onagi, D.P.; Keith, S.G.; Kuzyk, G.W.

    1996-01-01

    A number of aspects of the Canadian concept for nuclear fuel waste disposal are being assessed by Atomic Energy of Canada Limited (AECL) in a series of experiments at its Underground Research Laboratory (URL) near Lac du Bonnet, Manitoba, Canada. One of the major objectives of the work being carried out at the URL is to develop and evaluate the methods and technology to ensure safe, permanent disposal of Canada's nuclear fuel waste. In 1994, AECL excavated access tunnels and a laboratory room for the Quarried Block Fracture Migration Experiment (QBFME) at the 240 Level of the URL. This facility will be used to study the transport of radionuclides in natural fractures in quarried blocks of granite under in-situ groundwater conditions. The experiment is being carried out under a cooperative agreement with the Japan Atomic Energy Research Institute. The excavation of the QBFME access tunnels and laboratory was carried out using controlled blasting techniques that minimized blast-induced overpressure which could have damaged or interrupted other ongoing experiments in the vicinity. The majority of the blasts used conventional long delay non-electric detonators but a number of blasts were carried out using HANDIDET 250/6000 non-electric long delay detonator assemblies and HTD reg-sign non-electric short delay trunkline detonator assemblies. The tunnel and laboratory excavation was monitored to determine the levels of blast-induced overpressure. This paper describes the blasting and monitoring results of the blasts using HANDIDET non-electric detonator assemblies and the effectiveness of these detonators in reducing blast-induced overpressure

  15. The use of HANDIDET{reg_sign} non-electric detonator assemblies to reduce blast-induced overpressure at AECL`s Underground Research Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Onagi, D.P.; Keith, S.G.; Kuzyk, G.W. [AECL, Pinawa, Manitoba (Canada). Underground Research Lab.; Proudfoot, D.F. [ICI Explosives Canada, North Delta, British Columbia (Canada)

    1996-12-01

    A number of aspects of the Canadian concept for nuclear fuel waste disposal are being assessed by Atomic Energy of Canada Limited (AECL) in a series of experiments at its Underground Research Laboratory (URL) near Lac du Bonnet, Manitoba, Canada. One of the major objectives of the work being carried out at the URL is to develop and evaluate the methods and technology to ensure safe, permanent disposal of Canada`s nuclear fuel waste. In 1994, AECL excavated access tunnels and a laboratory room for the Quarried Block Fracture Migration Experiment (QBFME) at the 240 Level of the URL. This facility will be used to study the transport of radionuclides in natural fractures in quarried blocks of granite under in-situ groundwater conditions. The experiment is being carried out under a cooperative agreement with the Japan Atomic Energy Research Institute. The excavation of the QBFME access tunnels and laboratory was carried out using controlled blasting techniques that minimized blast-induced overpressure which could have damaged or interrupted other ongoing experiments in the vicinity. The majority of the blasts used conventional long delay non-electric detonators but a number of blasts were carried out using HANDIDET 250/6000 non-electric long delay detonator assemblies and HTD{reg_sign} non-electric short delay trunkline detonator assemblies. The tunnel and laboratory excavation was monitored to determine the levels of blast-induced overpressure. This paper describes the blasting and monitoring results of the blasts using HANDIDET non-electric detonator assemblies and the effectiveness of these detonators in reducing blast-induced overpressure.

  16. Electrical Energy Service Options: Deregulation Presents New Opportunities.

    Science.gov (United States)

    Matterson, Gary C.

    1995-01-01

    It is noted that federal deregulation of the electrical utility industry will allow colleges and universities to buy electrical services from suppliers who provide the best reliability and cost combination. Considerations are examined for the following options: purchasing an existing electrical substation, building a new substation, using on-site…

  17. Rokibaar Underground = Rock bar Underground

    Index Scriptorium Estoniae

    2008-01-01

    Rokibaari Underground (Küütri 7, Tartu) sisekujundus, mis pälvis Eesti Sisearhitektide Liidu 2007. a. eripreemia. Sisearhitekt: Margus Mänd (Tammat OÜ). Margus Männist, tema tähtsamad tööd. Plaan, 5 värv. vaadet, foto M. Männist

  18. Underground Politics

    DEFF Research Database (Denmark)

    Galis, Vasilis; Summerton, Jane

    of various kinds, as well as for identifying and displacing undesired individuals/groups/bodies. A case in point is a recently-established police project (REVA) in Sweden for strengthening the so-called internal border control. Specifically, several underground stations in Stockholm now have checkpoints......Public spaces are often contested sites involving the political use of sociomaterial arrangements to check, control and filter the flow of people (see Virilio 1977, 1996). Such arrangements can include configurations of state-of-the-art policing technologies for delineating and demarcating borders...... status updates on identity checks at the metro stations in Stockholm and reports on locations and time of ticket controls for warning travelers. Thus the attempts by authorities to exert control over the (spatial) arena of the underground is circumvented by the effective developing of an alternative...

  19. performance assessment of substation site earthing using fluke ...

    African Journals Online (AJOL)

    2013-03-01

    Mar 1, 2013 ... to analyze earth impedance in five power substations. Other conventional methods like the use of megger for ... Ohms or less [8], which power substation is among. The telecommunication industry has often used ... Three earth electrodes which are usually hard drawn bare copper rods were driven vertically ...

  20. The Future of Substations: Centralized Protection and Control

    OpenAIRE

    Thompson, Adam Craig

    2016-01-01

    Modern power substations continue to use hardware that is dated and resistant to modernization. This document discusses the basics of substations, identifies their weaknesses, and suggests a method of improvement. This suggestion implements a centralized protection and control system to make the overall system more robust and flexible to the ever changing power system landscape. MS

  1. Optimal Supercapacitor Energy Storage System Sizing for Traction Substations

    OpenAIRE

    Sirmelis, U; Zaķis, J; Grigāns, L

    2015-01-01

    In this paper authors present a method for optimal sizing of supercapacitor (SC) energy storage system (ESS) for braking energy recovery in tram network. The method is applicable for segmented tram networks with radial feeding topology and a stationary storage system installed in traction substation. The method is demonstrated for one traction substation of Riga public transport network.

  2. Electric Power Plants and Generation Stations, File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric substations, sewer plants, sewer pumpstations, water plants, water tanks http://www.harfordcountymd.gov/gis/Index.cfm, Published in 2011, 1:2400 (1in=200ft) scale, Harford County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Electric Power Plants and Generation Stations dataset current as of 2011. File name = UTILITIES - PARTIAL Data is incomplete. Contains electric trans lines, electric...

  3. Measurement of the Magnetic Fields from High-Voltage (230 kV Substations in Tehran and Assessment of Their Effects

    Directory of Open Access Journals (Sweden)

    Mahdieh Sharifi Fard

    2010-06-01

    Full Text Available Introduction: Recent industrial developments in human societies have caused rapid advancements in technologies of production and distribution of electricity, which in turn result in enhancement of power networks and utilization of high voltages. These networks and the high voltages in transfer lines cause the exposure to electric and magnetic fields. In this study, the situation regarding the magnetic fields from high-voltage (230 kV substations in Tehran was investigated. Material and Methods: In this study, 8 high-voltage (230 kV substations were selected (Shous, Shahid Firouzi, Ozgol, Kan, Tehranpars, Azadegan, Ghorkhane and Besat substations. The premises of each substation was divided into some stations and measurements were done in each one. Measurements were done according to the IEEE std 644-1994 Standard in a way that the device, specifically its probe, was kept at a height of 1 meter above the ground surface. Then, we tried to examine the probable effects of exposure to magnetic fields through the Essex questionnaire, with Cronbach coefficient of 94%, completed by the employees of the substations. These questionnaires were completed by substation operators as an exposed group (36 persons and the employees of the office section of the Tehran regional electric company as a witness group (32 persons. Results: The measured density in none of the stations exceeded the standard limits of the International Commission on Non-Ionizing Radiation Protection. With regard to the questionnaire results about mental and neurological, cardiac and respiratory, and gastrointestinal and auditory disorders, we observed significant differences between witness and exposed groups, however, regarding skin allergies, there was no significant difference. Conclusion: Among all control rooms, the highest measured magnetic field was 6.9 mG in the Ozgol Substation Control Room and the lowest was 2 mG in the post of Shahid Firouzi. The control room of Ozgol

  4. Online monitoring of accessories for underground electrical installations through acoustics emissions; Monitoreo en linea de accesorios de instalaciones electricas subterraneas mediante emisiones acusticas

    Energy Technology Data Exchange (ETDEWEB)

    Casals-Torrens, P. [Universidad Politecnica de Cataluna, Barcelona (Espana)]. E-mail: p.casals@upc.edu; Gonzalez-Parada, A. [Universidad de Guanajuato, Guanajuato (Mexico)]. E-mail: gonzaleza@salamanca.ugto.mx; Bosch-Tous, R. [Universidad Politecnica de Cataluna, Barcelona (Espana)

    2012-04-15

    The acoustic waves caused by Partial Discharges inside the dielectric materials, can be detected by acoustic emission (AE) sensors and analyzed in the time domain. The experimental results presented, show the online detection capability of these sensors in the environment near a cable accessory, such as a splice or terminal. The AE sensors are immune to electromagnetic interference and constitute a detection method non-intrusive and non-destructive, which ensures a galvanic decoupling with respect to electric networks, this technique of partial discharge detection can be applied as a test method for preventive or predictive maintenance (condition-based maintenance) to equipment or facilities of medium and high voltage in service and represents an alternative method to electrical detection systems, conventional or not, that continue to rely on the detection of current pulses. This paper presents characterization tests of the sensors AE through comparative tests of partial discharge on accessories for underground power cables. [Spanish] Las ondas acusticas provocadas por las descargas parciales en el interior de un dielectrico pueden ser detectadas por sensores de Emisiones Acusticas (EA) y analizadas en el dominio del tiempo. Los resultados experimentales que se presentan, evidencian la capacidad de deteccion en linea de estos sensores, en el entorno proximo a un accesorio de cable, empalme o terminal. Los sensores EA son inmunes a las interferencias electromagneticas, son un metodo de deteccion no destructivo y garantizan desacople galvanico respecto a la red electrica; esta tecnica de deteccion de descargas parciales puede ser aplicada como metodo de prueba para mantenimiento preventivo o predictivo (mantenimiento basado en la condicion), en equipos o instalaciones de media y alta tension en servicio, y representa una alternativa a los sistemas electricos de deteccion, convencionales o no, que continuan basandose en la deteccion del impulsos de corriente. En el

  5. 7 CFR 1726.76 - Substation and transmission line materials and equipment.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Substation and transmission line materials and... Substation and Transmission Facilities § 1726.76 Substation and transmission line materials and equipment. (a... $500,000 and for all materials. (b) Standards and specifications. Substation and transmission line...

  6. Evaluation of demand integrated substations; Utvaerdering av funktionsintegrerad fjaerrvaermecentral

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Sofie; Werner, Sven [FVB Sverige AB, Boraas (Sweden)

    2005-07-01

    Demand integrated substations contain an intelligent control unit, which recently has been developed by NordIQ Goeteborg AB. The purpose with this project has been to evaluate the benefits of this intelligent control unit. This evaluation project has been based on field measurement of hourly heat supply, circulated water, forward- and return temperatures in six substations with a 12 month reference period with the existing substation and another 12 month evaluation period with a demand integrated substation. The results from the evaluation show that: - The annual heat delivery was reduced by 10-11 % in average, when a new demand integrated substation replaced an existing conventional substation in the same building. - The annual cooling of the district heat fluid increased by 10-11 deg C, giving lower return temperatures in the district heating systems. The annual volume of circulated water was reduced with 33,200 m{sup 3} from the initial 112,800 m{sup 3} during the reference year. - The daily variation of the customer heat demand became less bumpy from lower morning peaks and heat demands moved to evenings and nights. The financial benefit from the intelligent control unit estimated as net present value is higher than the cost for new conventional substations. Applied to the whole Swedish district heat sector, this benefit has an annual value of about 1,6-2,0 billion SEK (180- 220 million Euro), corresponding to 7-9 % of the current price level for district heat in Sweden.

  7. Fault diagnosis methods for district heating substations

    Energy Technology Data Exchange (ETDEWEB)

    Pakanen, J.; Hyvaerinen, J.; Kuismin, J.; Ahonen, M. [VTT Building Technology, Espoo (Finland). Building Physics, Building Services and Fire Technology

    1996-12-31

    A district heating substation is a demanding process for fault diagnosis. The process is nonlinear, load conditions of the district heating network change unpredictably and standard instrumentation is designed only for control and local monitoring purposes, not for automated diagnosis. Extra instrumentation means additional cost, which is usually not acceptable to consumers. That is why all conventional methods are not applicable in this environment. The paper presents five different approaches to fault diagnosis. While developing the methods, various kinds of pragmatic aspects and robustness had to be considered in order to achieve practical solutions. The presented methods are: classification of faults using performance indexing, static and physical modelling of process equipment, energy balance of the process, interactive fault tree reasoning and statistical tests. The methods are applied to a control valve, a heat excharger, a mud separating device and the whole process. The developed methods are verified in practice using simulation, simulation or field tests. (orig.) (25 refs.)

  8. ALGORITHMIZATION OF PROBLEMS FOR OPTIMAL LOCATION OF TRANSFORMERS IN SUBSTATIONS OF DISTRIBUTED NETWORKS

    Directory of Open Access Journals (Sweden)

    M. I. Fursanov

    2014-01-01

    Full Text Available This article reflects algorithmization of search methods of effective replacement of consumer transformers in distributed electrical networks. As any electrical equipment of power systems, power transformers have their own limited service duration, which is determined by natural processes of materials degradation and also by unexpected wear under different conditions of overload and overvoltage. According to the standards, adapted by in the Republic of Belarus, rated service life of power transformers is 25 years. But it can be situations that transformers should be better changed till this time – economically efficient. The possibility of such replacement is considered in order to increase efficiency of electrical network operation connected with its physical wear and aging.In this article the faults of early developed mathematical models of transformers replacement were discussed. Early such worked out transformers were not used. But in practice they can be replaced in one substation but they can be successfully used  in other substations .Especially if there are limits of financial resources and the replacement needs more detail technical and economical basis.During the research the authors developed the efficient algorithm for determining of optimal location of transformers at substations of distributed electrical networks, based on search of the best solution from all sets of displacement in oriented graph. Suggested algorithm allows considerably reduce design time of optimal placement of transformers using a set of simplifications. The result of algorithm’s work is series displacement of transformers in networks, which allow obtain a great economic effect in comparison with replacement of single transformer.

  9. Risk management study for a zone substation project

    Energy Technology Data Exchange (ETDEWEB)

    Farr, M.S.; Lendich, M.J. [South East Queensland Electricity Corporation, Brisbane, QLD (Australia)

    1995-12-31

    A risk management study which was undertaken for a project that involved development of a new $A7.8 million substation at Robina in the Gold Coast area of South East Queensland is discussed in this paper. Project risk management techniques were used to analyse all the key stages of the project and the stake-holders for each stage. In conjunction with the stake-holders, attempts were made to identify all risks that could present an obstacle to the success of the project, and responses to each one were documented. A quantitative analysis of all the risks was then undertaken, and the risks prioritized. This led to the development of a detailed action plan which was implemented by the project manager. This structured approach to analysing the potential problem areas to the project proved to be an effective systematic means to manage the project from its infant stages through to construction. The success of this study has led to the acceptance of the techniques for future South East Queensland Electricity Corporation capital works projects. (author). 3 tabs., 3 figs. 2 refs.

  10. Research on Vibration Test in Urban Indoor Substation

    Science.gov (United States)

    Ma, Yuchao; Mo, Juan; Xu, Jin; Fan, Baozhen

    2018-01-01

    The problem of vibration and noise of urban indoor substations has becoming more and more socially concerned.The urban indoor substation of 110kV and its conjoined buildings were taken as the research object and the vibration tests of the transformer and each floor slab were respectively carried out.The sound vibration characteristics and sound transmission rules of the urban indoor substation were obtained through the time-frequency analysis and coherence analysis of the test data. The vibration spectrum of transformer body was mainly 100Hz together with its multiplying factors and the vibration characteristics of the floor slab were basically the same as those of the transformer body. it is crucial to control the vibration and noise transmission in the equipment floor of the urban indoor substation.

  11. Fuzzy logic based ELF magnetic field estimation in substations

    International Nuclear Information System (INIS)

    Kosalay, I.

    2008-01-01

    This paper examines estimation of the extremely low frequency magnetic fields (MF) in the power substation. First, the results of the previous relevant research studies and the MF measurements in a sample power substation are presented. Then, a fuzzy logic model based on the geometric definitions in order to estimate the MF distribution is explained. Visual software, which has a three-dimensional screening unit, based on the fuzzy logic technique, has been developed. (authors)

  12. Fuzzy logic based ELF magnetic field estimation in substations.

    Science.gov (United States)

    Kosalay, Ilhan

    2008-01-01

    This paper examines estimation of the extremely low frequency magnetic fields (MF) in the power substation. First, the results of the previous relevant research studies and the MF measurements in a sample power substation are presented. Then, a fuzzy logic model based on the geometric definitions in order to estimate the MF distribution is explained. Visual software, which has a three-dimensional screening unit, based on the fuzzy logic technique, has been developed.

  13. Analysis of Cooling Capability in Polish District Heating Substations

    OpenAIRE

    Markowicz, Catarina

    2012-01-01

    For a district heating company it is of importance to have an efficient and well performing system. A central part in the work to lower temperature levels in district heating networks is to acknowledge and improve cooling capability in substations. The aim of this thesis is to analyse substations in Polish district heating systems in order to identify reasons of poor cooling and to present suggestions of implementable measures. Furthermore, the economical saving potential from an improved coo...

  14. Dynamic Underground Stripping Demonstration Project

    International Nuclear Information System (INIS)

    Aines, R.; Newmark, R.; McConachie, W.; Rice, D.; Ramirez, A.; Siegel, W.; Buettner, M.; Daily, W.; Krauter, P.; Folsom, E.; Boegel, A.J.; Bishop, D.; udel, K.

    1992-03-01

    LLNL is collaborating with the UC Berkeley College of Engineering to develop and demonstrate a system of thermal remediation and underground imaging techniques for use in rapid cleanup of localized underground spills. Called ''Dynamic Stripping'' to reflect the rapid and controllable nature of the process, it will combine steam injection, direct electrical heating, and tomographic geophysical imaging in a cleanup of the LLNL gasoline spill. In the first 8 months of the project, a Clean Site engineering test was conducted to prove the field application of the techniques before moving to the contaminated site in FY 92

  15. Logistics background study: underground mining

    Energy Technology Data Exchange (ETDEWEB)

    Hanslovan, J. J.; Visovsky, R. G.

    1982-02-01

    Logistical functions that are normally associated with US underground coal mining are investigated and analyzed. These functions imply all activities and services that support the producing sections of the mine. The report provides a better understanding of how these functions impact coal production in terms of time, cost, and safety. Major underground logistics activities are analyzed and include: transportation and personnel, supplies and equipment; transportation of coal and rock; electrical distribution and communications systems; water handling; hydraulics; and ventilation systems. Recommended areas for future research are identified and prioritized.

  16. Melatonin metabolite levels in workers exposed to 60-Hz magnetic fields: work in substations and with 3-phase conductors.

    Science.gov (United States)

    Burch, J B; Reif, J S; Noonan, C W; Yost, M G

    2000-02-01

    Melatonin suppression by 50/60-Hz magnetic fields represents a plausible biological mechanism for explaining increased health risks in workers. Personal exposure to magnetic fields and ambient light, and excretion of the melatonin metabolite 6-hydroxymelatonin sulfate (6-OHMS), were measured over 3 consecutive workdays in electric utility workers. There was a magnetic field-dependent reduction in adjusted mean nocturnal and post-work 6-OHMS levels among men working more than 2 hours per day in substation and 3-phase environments and no effect among those working 2 hours or less. No changes were observed among men working in 1-phase environments. The results suggest that circular or elliptical magnetic field polarization, or another factor linked to substations and 3-phase electricity, is associated with magnetic field induced melatonin suppression in humans.

  17. The Canfranc Underground Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Amare, J. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Beltran, B. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Carmona, J.M. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Cebrian, S. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Garcia, E. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Irastorza, I.G. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Gomez, H. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Luzon, G. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Martinez, M. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Morales, J. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Ortiz de Solorzano, A. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Pobes, C. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Puimedon, J. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Rodriguez, A. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Ruz, J. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Sarsa, M.L. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Torres, L. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain); Villar, J.A. [Laboratory of Nuclear and High Energy Physics, University of Zaragoza. 50009 Zaragoza (Spain)

    2005-06-15

    This paper describes the forthcoming enlargement of the Canfranc Underground Laboratory (LSC) which will allow to host new international Astroparticle Physics experiments and therefore to broaden the European underground research area. The new Canfranc Underground Laboratory will operate in coordination (through the ILIAS Project) with the Gran Sasso (Italy), Modane (France) and Boulby (UK) underground laboratories.

  18. Review of the state of the art in passive and active noise mitigation technologies for substation transformers

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    A study was conducted in which proven methods and approaches for passive and active power transformer noise reduction and mitigation were analyzed. The project also identified and documented existing commercial products and technologies and the conditions where their application is most successful. In general, the study documented leading edge substation transformer noise reduction and mitigation technologies, based on a comprehensive literature review and surveys of electric utilities.

  19. Reducing Carbon Dioxide Emissions from Electricity Sector Using Smart Electric Grid Applications

    Directory of Open Access Journals (Sweden)

    Lamiaa Abdallah

    2013-01-01

    Full Text Available Approximately 40% of global CO2 emissions are emitted from electricity generation through the combustion of fossil fuels to generate heat needed to power steam turbines. Burning these fuels results in the production of carbon dioxide (CO2—the primary heat-trapping, “greenhouse gas” responsible for global warming. Applying smart electric grid technologies can potentially reduce CO2 emissions. Electric grid comprises three major sectors: generation, transmission and distribution grid, and consumption. Smart generation includes the use of renewable energy sources (wind, solar, or hydropower. Smart transmission and distribution relies on optimizing the existing assets of overhead transmission lines, underground cables, transformers, and substations such that minimum generating capacities are required in the future. Smart consumption will depend on the use of more efficient equipment like energy-saving lighting lamps, enabling smart homes and hybrid plug-in electric vehicles technologies. A special interest is given to the Egyptian case study. Main opportunities for Egypt include generating electricity from wind and solar energy sources and its geographical location that makes it a perfect center for interconnecting electrical systems from the Nile basin, North Africa, Gulf, and Europe. Challenges include shortage of investments, absence of political will, aging of transmission and distribution infrastructure, and lack of consumer awareness for power utilization.

  20. Power quality complex estimation at alternating current traction substations

    Directory of Open Access Journals (Sweden)

    D.O. Bosiy

    2013-08-01

    Full Text Available Purpose. At alternating current traction substations are used three-winding transformers. This scheme comes to significant costs from power quality disturbances at each supplier. The most significant power quality indices at alternating current traction substation are voltage deviation, voltage unbalance and harmonic distortion. The purpose of this article is power quality complex estimation at two traction substations that work on the one district of traction network. Methodology. The measurements were made according to accepted program during 24 hours with 1 sec discretization. A few power quality analyzers PM175 are used to record data with time synchronization. The scheme of measurements means that devices are connected through current and potential transformers at the each level of voltage. Findings. Voltage level at different substation is various due to power losses in primary network. The voltage in one phase of 1-st substation is bigger than in other phases. Voltage THD values according to standard requirements are below norm only for primary 154 kV networks. For another traction and regional networks voltage THD values are above norm value. The voltage unbalances in 154 kV networks are below voltage unbalance in 35 kV networks. Besides the voltage unbalance in 154 kV network is below 2 % that complies with the requirements of standard. At the same time we can consider that voltage and current spectrums consist from discrete harmonics with frequencies that multiples of the fundamental frequency. Originality. Voltages at the connection points of traction substations to supply lines are complex stationary random process that determines the voltage mode of the external power supply system of each traction substation. The flows of active and reactive power of the higher harmonics at AC traction substation are directed opposite power of the fundamental harmonic. The power flows on higher harmonics create the disturbing impact on related

  1. Conformational Sub-states and Populations in Enzyme Catalysis

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, Pratul K [ORNL; Doucet, Nicholas [INRS-Institut Armand-Frappier, University of Quebec; Chennubholta, C [University of Pittsburgh; Ramanathan, Arvind [ORNL

    2016-01-01

    reactants in the active site, chemical turnover, and release of products. In addition to formation of crucial structural interactions between enzyme and substrate(s), coordinated motions within the enzyme substrate complex allow reaction to proceed at a much faster rate, compared to the reaction in solution and in the absence of enzyme. An increasing number of enzyme systems show the presence of conserved protein motions that are important for function. A wide variety of motions are naturally sampled (over femtosecond to millisecond time-scales) as the enzyme complex moves along the energetic landscape, driven by temperature and dynamical events from the surrounding environment. Areas of low energy along the landscape form conformational sub-states, which show higher conformational populations than surrounding areas. A small number of these protein conformational sub-states contain functionally important structural and dynamical features, which assist the enzyme mechanism along the catalytic cycle. Identification and characterization of these higher-energy (also called excited) sub-states and the associated populations are challenging, as these sub-states are very short-lived and therefore rarely populated. Specialized techniques based on computer simulations, theoretical modeling, and nuclear magnetic resonance have been developed for quantitative characterization of these sub-states and populations. This chapter discusses these techniques and provides examples of their applications to enzyme systems.

  2. Detection of Periodic Beacon Loads in Electrical Distribution Substation Data

    Energy Technology Data Exchange (ETDEWEB)

    Hammerstrom, Donald J.; Guttromson, Ross T.; Lu, Ning; Boyd, Paul A.; Trudnowski, Daniel; Chassin, David P.; Bonebrake, Christopher A.; Shaw, James M.

    2006-05-31

    This research explores methods for identifying a whether a load is sending a signal to the utility SCADA system. Such a system can identify whether various loads are signialing using existing SCADA infrastructure, that is, without added, high cost communications infrastructure.

  3. Operation of industrial electrical substations. Part II: practical applications

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Jimenez, Juan J; Zerquera Izquierdo, Mariano D; Beltran Leon, Jose S; Garcia Martinez, Juan M; Alvarez Urena, Maria V; Meza Diaz, Guillermo [Universidad de Guadalajara (Mexico)]. E-mails: cheosj@yahoo.com; mdzi@hotmail.com; beltran5601@yahoo.com.mx; jmargarmtz@yahoo.com; victory_alvarez@telmexmail.com; depmec@cucei.udg.mx

    2013-03-15

    The practical application of the methodology explained in Part 1 in a Cuban industry is the principal objective of this paper. The calculus of the economical operation of the principal transformers of the industrial plant is shown of the one very easy form, as well as the determination of the equations of the losses when the transformers operate under a given load diagram. It is calculated the state load which will be passed to the operation in parallel. [Spanish] El objetivo principal de este trabajo es la aplicacion practica de la metodologia, en una industria cubana, que se explico en la Parte 1. El calculo de la operacion economica de los principales transformadores de la planta industrial se muestra de una forma muy facil, asi como la determinacion de las ecuaciones de las perdidas cuando los transformadores operan bajo un diagrama de carga dado. Se calcula la carga de estado que se pasa a la operacion en paralelo.

  4. Large-scale electricity storage utilizing reversible solid oxide cells combined with underground storage of CO2 and CH4

    DEFF Research Database (Denmark)

    Jensen, Søren Højgaard; Graves, Christopher R.; Mogensen, Mogens Bjerg

    2015-01-01

    , but unfortunately it is limited to mountainous regions and therefore difficult to expand. Emerging technologies like adiabatic compressed air energy storage (ACAES) or storage using conventional power-to-gas (P2G) technology combined with underground gas storage can be more widely deployed, but unfortunately...

  5. Occupational hazards and other problems related to the use of sulfur hexafluoride in metalclad substations

    Energy Technology Data Exchange (ETDEWEB)

    Theoret, A.; Gilbert, R.

    1976-10-01

    A review and a detailed analysis of present knowledge of the possible risks of asphyxiation and intoxication inherent in the operation of SF/sub 6/ substations and maintenance of electrical switchgear are presented. The danger of asphyxiation in SF/sub 6/ substations is based on the physical properties of this gas with regard to flow and diffusion. The diffusion of SF/sub 6/ into air as a function of time was calculated and the curves obtained provide a clear illustration of the tendency of this heavy gas to stagnate in low areas and the consequent risks of asphyxiation faced by personnel in such places. The problem of the decomposition of SF/sub 6/ in electrical switchgear leading to the formation of several irritant or toxic products is discussed together with the undesirable influence that certain contaminants, such as humidity, have on promoting decomposition. Several examples of the types of incident that can occur with SF/sub 6/-insulated equipment are described and discussed.

  6. Implementation of computational model for the evaluation of electromagnetic susceptibility of the cables for communication and control of high voltage substations; Implementacao de modelo computacional para a avaliacao da suscetibilidade eletromagnetica dos cabos de comunicacao e controle de subestacoes de alta tensao

    Energy Technology Data Exchange (ETDEWEB)

    Sartin, Antonio C.P. [Companhia de Transmissao de Energia Eletrica Paulista (CTEEP), Bauru, SP (Brazil); Dotto, Fabio R.L.; Sant' Anna, Cezar J.; Thomazella, Rogerio [Fundacao para o Desenvolvimento de Bauru, SP (Brazil); Ulson, Jose A.C.; Aguiar, Paulo R. de [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Bauru, SP (Brazil)

    2009-07-01

    This work show the implementation of a electromagnetic model for supervision cable, protection, communication and high voltage substations control that was investigated in literature and adapted. The model was implemented by using a computational tool in order to obtain the electromagnetic behavior of various cables used in CTEEP substation, subject to several sources of electromagnetic interference in this inhospitable environment, such as lightning strikes, outbreaks of maneuvers switching and the corona effect. The results obtained in computer simulations were compared with results of laboratory tests carried out on a lot of cables that represent those systems that are present in substations 440 kV. This study characterized the electromagnetic interference, ranked them, identified possible susceptible points in the substation, which contributed to the development of a technical procedure that minimizes unwanted effects caused in communication systems and substation control. This developed procedure also assured the maximum reliability and availability in the operation of the electrical power system to the company.

  7. Decision 2010-021 : TransAlta Wind Ardenville wind plant and substation : application no. 1604970, proceeding ID 260

    International Nuclear Information System (INIS)

    2010-01-01

    TransAlta Wind, a wholly owned subsidiary of TransAlta Corporation, filed an application in April 2009 to construct and operate the Ardenville wind farm and substation in Alberta. The wind farm consists of 23 wind turbines, each rated at 3 MW, for a total installed capacity of 69 MW. The wind farm would be connected to the Alberta Interconnected Electric System at the substation. TransAlta anticipates that a new 138-kV transmission line will be required and has contacted the transmission facilities for the future applications. The Alberta Utilities Commission issued a notice to all interested parties and landholders within 2 km of the proposed wind farm. Two residents raised concerns regarding the use of fossil fuels and alternative fuels, ecological impacts and aesthetic impacts of wind farms and land values. Upon review of information, the Commission was satisfied that approval of the application was in the public interest and that the wind farm complies with all regulatory requirements, including sound levels. Pursuant to sections 11, 14 and 15 of the Hydro and Electric Energy Act, the Commission approved the application and granted approval to TransAlta Wind to construct and operate the Ardenville wind power plant and substation.

  8. Assessment of the risk of failure of high voltage substations due to environmental conditions and pollution on insulators.

    Science.gov (United States)

    Castillo Sierra, Rafael; Oviedo-Trespalacios, Oscar; Candelo, John E; Soto, Jose D

    2015-07-01

    Pollution on electrical insulators is one of the greatest causes of failure of substations subjected to high levels of salinity and environmental pollution. Considering leakage current as the main indicator of pollution on insulators, this paper focuses on establishing the effect of the environmental conditions on the risk of failure due to pollution on insulators and determining the significant change in the magnitude of the pollution on the insulators during dry and humid periods. Hierarchical segmentation analysis was used to establish the effect of environmental conditions on the risk of failure due to pollution on insulators. The Kruskal-Wallis test was utilized to determine the significant changes in the magnitude of the pollution due to climate periods. An important result was the discovery that leakage current was more common on insulators during dry periods than humid ones. There was also a higher risk of failure due to pollution during dry periods. During the humid period, various temperatures and wind directions produced a small change in the risk of failure. As a technical result, operators of electrical substations can now identify the cause of an increase in risk of failure due to pollution in the area. The research provides a contribution towards the behaviour of the leakage current under conditions similar to those of the Colombian Caribbean coast and how they affect the risk of failure of the substation due to pollution.

  9. Architecture for internet enabled measurements in a district heating substation laboratory

    OpenAIRE

    Jomni, Yassin; Yliniemi, Kimmo; van Deventer, Jan; Delsing, Jerker

    2005-01-01

    An architecture for the energy measurement and control and monitoring at a district heating substation is propsoed. A district heating substation is comprised of a set of sensors and actuators crutial for the well being of the substation. We want to make the data from the sensors available over the internet and provide access to the control system of the district heating substation over the internet. This technology will be implemented in a district heating laboratory being constructed at Lul...

  10. Underground Layout Configuration

    International Nuclear Information System (INIS)

    A. Linden

    2003-01-01

    The purpose of this analysis was to develop an underground layout to support the license application (LA) design effort. In addition, the analysis will be used as the technical basis for the underground layout general arrangement drawings

  11. Underground pipeline corrosion

    CERN Document Server

    Orazem, Mark

    2014-01-01

    Underground pipelines transporting liquid petroleum products and natural gas are critical components of civil infrastructure, making corrosion prevention an essential part of asset-protection strategy. Underground Pipeline Corrosion provides a basic understanding of the problems associated with corrosion detection and mitigation, and of the state of the art in corrosion prevention. The topics covered in part one include: basic principles for corrosion in underground pipelines, AC-induced corrosion of underground pipelines, significance of corrosion in onshore oil and gas pipelines, n

  12. SF6 gas insulated power substations. Effects of fast transients (VFT) on the equipment and adjacent equipment of the Itaipu Binacional SF6 insulated power substations; Subestaciones aisladas a gas SF6. Efectos de los transitorios rapidos (VFT's) sobre equipos y equipos adyacentes de las SE's SF6 de Itaipu Binacional

    Energy Technology Data Exchange (ETDEWEB)

    Santacruz Martinez, Miguel [Usina Hidroelectrica de Itaipu, Assuncao (Paraguay)]. E-mail: santcruz@itaipu.gov.py

    2001-07-01

    With the operation starting of the S F6 gas substations in high voltage systems occurs a new form of overvoltage presently known as Very Fast Transients. This paper aims the phenomenon characterization, defining the origins and the behaviour of the electric systems, and briefly presents the damages caused by the phenomenon on the equipment and adjacent equipment of S F6 gas insulated substations of the Itaipu Binacional, mainly on the power transformers and oil/S F6 isolators of the step-up transformers. These equipment was modified or are been modified as a consequence of the this overvoltage effects.

  13. Underground laboratories in Europe

    International Nuclear Information System (INIS)

    Coccia, E

    2006-01-01

    The only clear evidence today for physics beyond the standard model comes from underground experiments and the future activity of underground laboratories appears challenging and rich. I review here the existing underground research facilities in Europe. I present briefly the main characteristics, scientific activity and perspectives of these Laboratories and discuss the present coordination actions in the framework of the European Union

  14. Elucidation of a Peculiar Phenomenon of Voltage Measuring at a Substation

    Science.gov (United States)

    Takafuji, Kouya; Satou, Takashi; Itou, Hisanori; Kouda, Isao; Haba, Toshiaki; Satake, Atushi; Haginomori, Eiichi

    An automatic fault-recorder installed in a substation of Chubu Electric Power Company detected a peculiar phenomenon that bus-bar voltage fell to around 20-30% of the nominal value for a short time (about 8-10 cycles) though electric current didn't change during the period. The phenominon was recorded several times. In this paper, we analyzed the origin of this phenomenon and conducted simulations by EMTP. As a result, we estimated that this phenomenon occurred by the saturation of VT (voltage transformer), and this saturation caused by lightning strokes to the transmission line with line arresters, which have been increasingly installed in recent years. Moreover, we evaluated the influence of the phenomenon to protection relays.

  15. Modeling of a 22.9 kV 50 MVA superconducting power cable based on PSCAD/EMTDC for application to the Icheon substation in Korea

    Science.gov (United States)

    Lee, S.; Yoon, J.; Lee, B.; Yang, B.

    2011-11-01

    Two projects for high temperature superconducting (HTS) power cable have been carried out in Korea since 2001. One of them is a HTS cable project in DAPAS (Development of Advanced Power system by Applied Superconductivity technologies) program funded by the Ministry of Education, Science and Technology. In this project, LS Cable Ltd. (LSC) and Korea Electrotechnology Research Institute (KERI) jointly developed a 22.9 kV, 50 MVA, 3 phase, 100 m HTS cable using first generation (1G) HTS wire in 2006. The HTS cable system has been tested in a power test center of Korea Electric Power Corporation (KEPCO). LSC and KEPCO have been developing a 22.9 kV, 50 MVA, 3 phase, 500 m HTS cable system using second generation (2G) HTS wire since 2008, based on the technology of the DAPAS project. This project is called as GENI (Green Superconducting Electric Power Network at the Icheon Substation) project. The target of GENI project is to install and operate the HTS cable system in the Icheon substation located in near Seoul. In order to analyze the Icheon substation power system employing the HTS cable, an analysis model of the HTS cable is necessary. This paper describes the development of an analysis model for the 22.9 kV, 50 MVA HTS cable that will be applied to the Icheon substation in Korea.

  16. Underground laboratory in China

    Science.gov (United States)

    Chen, Heshengc

    2012-09-01

    The underground laboratories and underground experiments of particle physics in China are reviewed. The Jinping underground laboratory in the Jinping mountain of Sichuan, China is the deepest underground laboratory with horizontal access in the world. The rock overburden in the laboratory is more than 2400 m. The measured cosmic-ray flux and radioactivities of the local rock samples are very low. The high-purity germanium experiments are taking data for the direct dark-matter search. The liquid-xenon experiment is under construction. The proposal of the China National Deep Underground Laboratory with large volume at Jinping for multiple discipline research is discussed.

  17. Optimal Allocation of Smart Substations in a Distribution System Considering Interruption Costs of Customers

    DEFF Research Database (Denmark)

    Sun, Lei; You, Shi; Hu, Junjie

    2016-01-01

    number and allocation of smart substations in a given distribution system is presented, with the upgrade costs of substations and the interruption costs of customers taken into account. Besides, the reliability criterion is also properly considered in the model. By linearization strategies, the SSAM......One of the major functions of a smart substation (SS) is to restore power supply to interrupted customers as quickly as possible after an outage. The high cost of a smart substation limits its widespread utilization. In this paper, a smart substation allocation model (SSAM) to determine the optimal...

  18. IEC 61850 – for much more than substations

    OpenAIRE

    Etherden, Nicholas; Öhlen, Carl

    2010-01-01

    IEC61850 is a standardized concept for information handling and communication for power utility automation. It is NOT just another protocol. IEC 61850 is today being expanded to apply to many domains beyond the original scope of the substation. Figure 1 illustrates the Expansion of IEC 61850 world to both control centre communication and modelling of communication with renewable energy resources.

  19. Performance Assessment of Substation Site Earthing Using Fluke ...

    African Journals Online (AJOL)

    This study utilizes the automatic frequency control (AFC) feature in Fluke 1625 ground tester to analyze earth impedance in ve power substations. Other conventional methods like the use of megger for impedance test runs short of responding to variation in supply frequency and not trustworthy. Earthing is the fundamental ...

  20. SUBSTATIONS OF DISTRICT HEATING SYSTEMS WITH PULSE COOLANT CIRCULATION

    Directory of Open Access Journals (Sweden)

    Andrey N. Makeev

    2017-01-01

    Full Text Available Abstract. Objectives The aim of the study is to generalise the results of the application of technologies and means for organising pulse coolant flow within a district heating system in order to increase its energy efficiency based on the organisation of local hydraulic shocks and the subsequent use of their energy to ensure the purification of heat energy equipment, intensify the heat transfer process and realise the possibility of transforming the available head from one hydraulic circuit to another. Methods Substations connecting the thermal power installations of consumers with heat networks via dependent and independent schemes are analytically generalised. The use of pulse coolant circulation is proposed as a means of overcoming identified shortcomings. Results Principal schemes of substations with pulse coolant circulation for dependent and independent connection of thermal power installations are detailed. A detailed description of their operation is given. The advantages of using pulse coolant circulation in substations are shown. The materials reflecting the results of the technical implementation and practical introduction of this technology are presented. Conclusion Theoretical analysis of the operation of the basic schemes of substations with pulse coolant circulation and the results of their practical application, as well as the materials of scientific works devoted to the use of the energy of a hydraulic impact and the study of the effect of pulse coolant flow on thermal and hydrodynamic processes, have yielded a combination of factors reflecting technical and economic rationality of application of pulse coolant circulation. 

  1. SYSTEM ANALYSIS OF EXTERNAL POWER SUPPLY OF RAILWAYS TRACTION SUBSTATIONS

    Directory of Open Access Journals (Sweden)

    I.V. Domansky

    2013-06-01

    Full Text Available A system analysis of external power supply circuits of railways traction substations over the period of 1993 through 2011 and power supply circuits projects up to 2016 in the market economy environment and under standard requirements of the power industry of Ukraine is conducted

  2. Evaluation of the Optimal Connection of Power Transformers in the Substations of a Hospital

    Directory of Open Access Journals (Sweden)

    Carlos Javier Renedo

    2018-02-01

    Full Text Available Transformers are installed in power distribution systems to perform changes in supply voltage. Large consumers often have several transformers installed in parallel to ensure continuity of supply in the event of failure. These machines can achieve very high efficiency, but their efficiency is not constant since it depends on the power demanded at each time. Therefore, the level of efficiency that correspond to the operation of a specific transformer depends on two factors: machine technical characteristics and electrical load. In this work, the authors have proposed a methodology which shows the optimal number of transformers to be connected at each period in the substations of a large Spanish hospital, in order to achieve the maximum seasonal efficiency of these machines. The results of the energy saving are determined with respect to the current situation, in which all the transformers are permanently connected. On the other hand, the European Union has established a new regulation that sets the minimum energy efficiency requirements for new power transformers. This efficiency improvement is proposed to be applied gradually in two stages, a first limit came into force in 2015, while a more restrictive approach will appear in the year 2021. This work has also studied the potential energy savings that would occur when the substations of the hospital have more efficient transformers complying with the new European Regulation 548/2014.

  3. Principles for construction the compensators of reactive power with voltage stabilization for transformer substations

    Science.gov (United States)

    Vlasayevsky, Stanislav; Klimash, Stepan; Klimash, Vladimir

    2017-10-01

    Based on the booster transformer and the transistor converter with a DC link, a system is proposed for fast and accurate unloading the electric network from reactive power with simultaneous stabilization of voltage among consumers. The system contains a discrete stage of reactive power compensation and adjustable part. The adjustable part includes series and parallel reactive power compensators. The series compensator consists of a booster transformer, a voltage inverter and is designed to be switched on to the high voltage of the transformer substations. The parallel compensator consists of a rectifier with an input choke and is connected to the low voltage of the substation. The rectifier and inverter are connected by a DC link with an LC filter. The rectifier regulates the output voltage and the phase of the sinusoidal input current. The inverter regulates the magnitude and phase of the voltage on the control winding of the booster transformer. The rectifier and inverter control systems are synchronized with the network and with pulse width modulation.

  4. On-site Smart Operation and Maintenance System for Substation Equipment Based on Mobile Network

    Directory of Open Access Journals (Sweden)

    Lin Cheng

    2018-03-01

    Full Text Available The maintenance of substations is crucial for the safety of the electrical grid and power industry. However, for long time, the maintenance teams in the field and the experts in the power companies are divided. The data and expertise exchanges between the on-site maintenance teams and data center are delayed due to the lack of effective communication. This paper introduces an on-site smart operation maintenance system for substation equipment based on mobile network. It is able to establish real-time communication and data exchange channels between the maintenance teams and data center. It consists of an operation and maintenance system platform located on the data center side and smart operation and maintenance boxes with mobile APP which are carried to the field side by the maintenance teams. As the kernel of the system, the smart boxes are bridges between the data center and operation sites. On one hand, it is able to formally upload data to the data center in real-time. One the other hand, the operation and maintenance personnel are able to call for help from the resource on the data center anytime. Using the system proposed in the paper, both efficiency of the operation and maintenance and the normalization of the data can be improved.

  5. Electricity Delivery and its Environmental Impacts

    Science.gov (United States)

    Explains electricity delivery in the U.S. and its impacts on the environment. After a centralized power plant generates electricity, the electricity must be delivered to the end-user. Follow the path of electricity through transmission, substation, and dis

  6. Evaluation of current densities and total contact currents in occupational exposure at 400 kV substations and power lines.

    Science.gov (United States)

    Korpinen, Leena H; Elovaara, Jarmo A; Kuisti, Harri A

    2009-04-01

    This investigation studied the current densities in the neck and total contact currents in occupational exposure at 400 kV substations and power lines. Eight voluntary workers simulated their normal work tasks using the helmet-mask measuring system. In all, 151 work tasks with induced current measurements were made. Work situations were: tasks in 400 kV substations, tasks in 400-110 kV towers and the cutting of vegetation under 400 kV power lines. The average current density in the neck was estimated from the current induced in the helmet. The calculated maximum average current densities in the neck varied from 1.5 to 6.4 mA/m(2) and the maximum total contact currents from 66.8 to 458.4 microA. The study shows that the maximum average current densities and the total contact currents (caused by electric field) in occupational exposure at 400 kV substations and power lines does not exceed the limit and action values (10 mA/m(2) and 1 mA) of the new EU-directive 2004/40/EC (live-line bare-hand works excluded). (c) 2009 Wiley-Liss, Inc.

  7. Advances in the diagnosis of substations primary equipment by means of high sensitivity techniques; Avances en el diagnostico de equipo primario de subestaciones mediante tecnicas de alta sensibilidad

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Colon H, V. Rodolfo; Nava G, J. Armando; Azcarraga R, Carlos G [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2005-07-01

    In an electrical system, the substations primary equipment is integrated by the power transformers, the instrument transformers, the breakers and the interconnection circuits (energy cables). At the present time, the described primary equipment has been integrated in an arrangement denominated encapsulated substation that presents dimensional and aesthetic advantages in the conventional substations. Nevertheless, the isolation involved in this type of substations means new challenges when carrying out its diagnosis in a planned way or after the appearance of a fault. In this sense, the insulating and electromechanical system of the primary equipment of substations must be evaluated in a programmed way or be constantly monitored. This with the final purpose of detecting incipient problems that could evolve towards a fault or to the diminution of the electrical system reliability. [Spanish] En un sistema electrico, el equipo primario de subestaciones esta integrado por los transformadores de potencia, los transformadores de instrumento, los interruptores y los circuitos de interconexion (cables de energia). En la actualidad, el equipo primario descrito se ha integrado en un arreglo denominado subestacion encapsulada que presenta ventajas dimensionales y esteticas sobre las subestaciones convencionales. Sin embargo, el aislamiento involucrado en este tipo de subestaciones significa nuevos retos al efectuar su diagnostico de manera planeada o despues de presentarse una falla. En este sentido, el sistema aislante y electromecanico del equipo primario de subestaciones debe ser evaluado de manera programada o monitoreado constantemente. Ello con la finalidad de detectar problemas incipientes que pudieran evolucionar hacia una falla o la disminucion de la confiabilidad del sistema electrico.

  8. Monitoring of electromagnetic pollution inside switchyard substation ...

    African Journals Online (AJOL)

    The aim of this paper is to carried out an experimental characterization of the electromagnetic environment beneath a selected circuit of two 220Kv power lines inside El-Hadjar electrical post often requiring maintenance. An analytical calculus method is proposed in order to accomplish this study. The model of the circuit of ...

  9. Underground laboratories in Asia

    Science.gov (United States)

    Lin, Shin Ted; Yue, Qian

    2015-08-01

    Deep underground laboratories in Asia have been making huge progress recently because underground sites provide unique opportunities to explore the rare-event phenomena for the study of dark matter searches, neutrino physics and nuclear astrophysics as well as the multi-disciplinary researches based on the low radioactive environments. The status and perspectives of Kamioda underground observatories in Japan, the existing Y2L and the planned CUP in Korea, India-based Neutrino Observatory (INO) in India and China JinPing Underground Laboratory (CJPL) in China will be surveyed.

  10. Underground Storage Tank (working)

    Data.gov (United States)

    Vermont Center for Geographic Information — Database contains information on ownership and system construction for underground storage tank facilities statewide. Database was developed in early 1990's for...

  11. Underground laboratories in Asia

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Shin Ted, E-mail: linst@mails.phys.sinica.edu.tw [College of Physical Science and Technology, Sichuan University, Chengdu 610064 China (China); Yue, Qian, E-mail: yueq@mail.tsinghua.edu.cn [Key Laboratory of Particle and Radiation Imaging (Ministry of Education) and Department of Engineering Physics, Tsinghua University, Beijing 100084 China (China)

    2015-08-17

    Deep underground laboratories in Asia have been making huge progress recently because underground sites provide unique opportunities to explore the rare-event phenomena for the study of dark matter searches, neutrino physics and nuclear astrophysics as well as the multi-disciplinary researches based on the low radioactive environments. The status and perspectives of Kamioda underground observatories in Japan, the existing Y2L and the planned CUP in Korea, India-based Neutrino Observatory (INO) in India and China JinPing Underground Laboratory (CJPL) in China will be surveyed.

  12. Underground laboratories in Asia

    International Nuclear Information System (INIS)

    Lin, Shin Ted; Yue, Qian

    2015-01-01

    Deep underground laboratories in Asia have been making huge progress recently because underground sites provide unique opportunities to explore the rare-event phenomena for the study of dark matter searches, neutrino physics and nuclear astrophysics as well as the multi-disciplinary researches based on the low radioactive environments. The status and perspectives of Kamioda underground observatories in Japan, the existing Y2L and the planned CUP in Korea, India-based Neutrino Observatory (INO) in India and China JinPing Underground Laboratory (CJPL) in China will be surveyed

  13. Digital substation based on IEC 61850 : its features and benefits for power system protection

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J.; Dahlgren, M. [ABB AB Corporate Research, Vasteras (Sweden)

    2008-07-01

    This paper described features of modern digital substations with particular reference to protection and control systems that are vital to power systems security and safety. Protection relays in substations have evolved from electro-mechanical relays to static relays in the 1970s, to microprocessor based relays in the 1980s, to present-day multifunctional numerical relays with strong communication facilities such as internet connections. In order to maximize the use of microprocessor based numerical relays, many different communication protocols have been introduced into substation automation systems to form station level monitoring and control functions. The breakthrough in modern substation protection and control systems was the introduction of the advanced standard known as IEC61850. With the new standard, protection relays can communicate with each other without using protocol converters. The modern substations will not only permit a common communication link within a substation secondary system, but create the possibility for even higher level integration of protection and control functions. Non-conventional sensors for current and voltage inputs has created a need to optimize the structure of modern substations due to the simplified and standard digital outputs from those new sensors. This paper described the development stages of modern technology in substation secondary systems and then described the features for a modern digital substation in considering practical evolution of substations in terms of data acquisition and security. The main benefit of such a power system is better use of real time data for optimized control of a safe power system. 7 refs., 8 figs.

  14. TWRS privatization phase 1 electrical power system

    International Nuclear Information System (INIS)

    Singh, G.

    1997-01-01

    This document includes Conceptual Design Report (CDR) for a new 11 km (7 miles) 230 kV transmission line and a new 40 MVA substation (A6) which will be located east of Grout Facility in 200E Area tank farm. This substation will provide electrical power up to 20 MW each for two private contractor facilities for immobilization and disposal of low activity waste (LAW)

  15. TWRS privatization phase 1 electrical power system

    Energy Technology Data Exchange (ETDEWEB)

    Singh, G.

    1997-05-30

    This document includes Conceptual Design Report (CDR) for a new 11 km (7 miles) 230 kV transmission line and a new 40 MVA substation (A6) which will be located east of Grout Facility in 200E Area tank farm. This substation will provide electrical power up to 20 MW each for two private contractor facilities for immobilization and disposal of low activity waste (LAW).

  16. MFTF 230 kV pulsed power substation

    International Nuclear Information System (INIS)

    Wilson, J.H.

    1979-01-01

    The Mirror Fusion Test Facility (MFTF) currently under construction at the Lawrence Livermore Laboratory includes a Sustaining Neutral Beam Power Supply System (SNBPSS) consisting of 24 power-supply sets. The System will operate in long pulses (initially .5 seconds and eventually 30 seconds) at high power (200 MW), which will necessitate a large source of ac power. To meet this requirement, a new 230-kV substation is also being built at LLL. The constraints of cost, equipment protection, short operating lifetime (10 years), and reliability dictated a unique substation design. Its unusual features include provisions for fast fault detection and tripping, a capability for limiting ground fault current, low impedance, and economical design

  17. Abnormal Appearance Detection of Substation Based on Image Comparison

    Directory of Open Access Journals (Sweden)

    Zhang Xu

    2016-01-01

    Full Text Available Based on image comparison, a novel algorithm for abnormal appearance detection of substation is proposed. Previous spatial states of an object are compared to its current representation in a digital image. Firstly, saliency maps are acquired using a fast implementation method of salient region detection. Based on saliency maps, image registration was completed by ORB (Oriented Fast and Rotated Brief. Then, sliding widow algorithm is applied to transform the whole image comparison problem into sub-image comparison problem. Textural feature and shape feature vectors (TSFVs representing contents of images are generated by feature level fusion. Finally, decisions are automatically made as to whether or not change at the outline has occurred by the Euclidean distance of TEFVs. Experimental results show that the proposed method has good performance in abnormal appearance detection of substation.

  18. Effect of extremely low frequency electromagnetic field exposure on sleep quality in high voltage substations.

    Science.gov (United States)

    Barsam, Tayebeh; Monazzam, Mohammad Reza; Haghdoost, Ali Akbar; Ghotbi, Mohammad Reza; Dehghan, Somayeh Farhang

    2012-11-30

    This study aims to investigate the effect of extremely low frequency electromagnetic fields exposure on sleep quality in high voltage substations (132, 230 and 400 KV) in Kerman city and the suburbs. For this purpose, the electric field intensity and magnetic flux density were measured in different parts of substations, and then the occupational exposure was estimated by averaging electric field intensity and magnetic flux density in a shift work. The cases comprised 67 workers who had been exposed to electromagnetic fields in age range of 24-57 and the controls were 110 persons the age ranged 24-50 years. Sleep quality of both groups was evaluated by the Pittsburgh Sleep Quality Index questionnaire (PSQI). Finally, these data were subjected to statistical analysis. The results indicated that 90.5% of cases and 85.3% of controls had the poor quality sleep according to PSQI (P-value=0.615). Total sleep quality score mean for the case and control groups were 10.22 ± 3.4 and 9.74 ± 3.62 (P-value=0.415) ,respectively. Meantime to fall asleep for cases(35.68 ± 26.25 min) was significantly higher than for controls (28.89 ± 20.18 min) (P-value=0.002). Cases had average sleep duration of 5.49 ± 1.31 hours, which was lower ascompared with control subjects (5.90 ± 1.67hours). Although there was a higher percentage for the case group with poor sleep quality than the control group, but no statistically significant difference was observed.

  19. A New Approach to Detection of Systematic Errors in Secondary Substation Monitoring Equipment Based on Short Term Load Forecasting

    Directory of Open Access Journals (Sweden)

    Javier Moriano

    2016-01-01

    Full Text Available In recent years, Secondary Substations (SSs are being provided with equipment that allows their full management. This is particularly useful not only for monitoring and planning purposes but also for detecting erroneous measurements, which could negatively affect the performance of the SS. On the other hand, load forecasting is extremely important since they help electricity companies to make crucial decisions regarding purchasing and generating electric power, load switching, and infrastructure development. In this regard, Short Term Load Forecasting (STLF allows the electric power load to be predicted over an interval ranging from one hour to one week. However, important issues concerning error detection by employing STLF has not been specifically addressed until now. This paper proposes a novel STLF-based approach to the detection of gain and offset errors introduced by the measurement equipment. The implemented system has been tested against real power load data provided by electricity suppliers. Different gain and offset error levels are successfully detected.

  20. A New Approach to Detection of Systematic Errors in Secondary Substation Monitoring Equipment Based on Short Term Load Forecasting.

    Science.gov (United States)

    Moriano, Javier; Rodríguez, Francisco Javier; Martín, Pedro; Jiménez, Jose Antonio; Vuksanovic, Branislav

    2016-01-12

    In recent years, Secondary Substations (SSs) are being provided with equipment that allows their full management. This is particularly useful not only for monitoring and planning purposes but also for detecting erroneous measurements, which could negatively affect the performance of the SS. On the other hand, load forecasting is extremely important since they help electricity companies to make crucial decisions regarding purchasing and generating electric power, load switching, and infrastructure development. In this regard, Short Term Load Forecasting (STLF) allows the electric power load to be predicted over an interval ranging from one hour to one week. However, important issues concerning error detection by employing STLF has not been specifically addressed until now. This paper proposes a novel STLF-based approach to the detection of gain and offset errors introduced by the measurement equipment. The implemented system has been tested against real power load data provided by electricity suppliers. Different gain and offset error levels are successfully detected.

  1. Transient phenomena due to disconnect switching in high voltage substations

    Energy Technology Data Exchange (ETDEWEB)

    Shuette, A. [Siemens AG, Erlangen (Germany); Rodrigo, H. [Royal Melbourne Institute of Technology, Melbourne (Australia). Dept. of Electrical Engineering

    1999-07-01

    Field measurements in a high voltage switchyard during disconnector switching is presented. These measurements are compared with those obtained in a model circuit, set up in our High Voltage laboratory. The need for electromagnetic compatibility in substation equipment, due to its electromagnetic interference is discussed. The level of overvoltage measured in the present work is discussed in the light of those available in the literature. (author)

  2. Population Stabilization in India: A Sub-State level Analysis

    OpenAIRE

    Purohit C, Dr Brijesh

    2007-01-01

    The study aims at analyzing economic and policy factors impinging upon population stabilization measures at the district (sub-state level) in India. It reflects upon popularly debated notions, namely, that development is the best contraceptive or whether contraceptive is the best development. In order to reflect upon this notion, we hypothesize that the factors determining the success of population stabilization measures are likely to be different across rich and poor states. It is more likel...

  3. A Digital Power Quality Monitoring Equipment Designed for Digital Substation

    Science.gov (United States)

    Li, Wei; Wang, Xin; Geng, Jiewen

    2018-01-01

    Taking into account both current status and development trend of digital substation, this paper proposed a design of a new multi-channelled digital power quality monitoring equipment with high compatibility. The overall functional structure, hardware architecture, software architecture, interface architecture and some key techniques such as IEC 61850 modelling of transient event and harmonic measurement method under the condition of non-synchronous sampling are described in this paper.

  4. Radionuclides in an underground environment

    International Nuclear Information System (INIS)

    Thompson, J.L.

    1996-01-01

    In the 100 years since Becquerel recognized radioactivity, mankind has been very successful in producing large amounts of radioactive materials. We have been less successful in reaching a consensus on how to dispose of the billions of curies of fission products and transuranics resulting from nuclear weapons testing, electrical power generation, medical research, and a variety of other human endeavors. Many countries, including the United States, favor underground burial as a means of disposing of radioactive wastes. There are, however, serious questions about how such buried wastes may behave in the underground environment and particularly how they might eventually contaminate water, air and soil resources on which we are dependent. This paper describes research done in the United States in the state of Nevada on the behavior of radioactive materials placed underground. During the last thirty years, a series of ''experiments'' conducted for other purposes (testing of nuclear weapons) have resulted in a wide variety of fission products and actinides being injected in rock strata both above and below the water table. Variables which seem to control the movement of these radionuclides include the physical form (occlusion versus surface deposition), the chemical oxidation state, sorption by mineral phases of the host rock, and the hydrologic properties of the medium. The information gained from these studies should be relevant to planning for remediation of nuclear facilities elsewhere in the world and for long-term storage of nuclear wastes

  5. Wireless sensing of substation parameters for remote monitoring and analysis

    Directory of Open Access Journals (Sweden)

    Ayindrila Roy

    2015-03-01

    Full Text Available This paper aimed to monitor the different bus parameters in a substation from a centralized control room with the help of Zigbee enabled wireless sensor network (WSN. The parameters such as magnitude and phase angles of voltage and current, frequency, rate-of-change-of-frequency (ROCOF, active and reactive powers are measured using a state-of-the-art customized Zigbee enabled phasor measurement unit (ZPMU. The data from different ZPMUs at different bus nodes are acquired with the help of WSN system in order to have a centralized monitoring of different equipments load status. The coordination among different parameters for different buses and/or equipment is done from a centralized control room within the substation or plant with the help of substation management software and Zigbee networking. The data thus collected are utilized to study the power flow status of the different buses on real time basis and are stored within a server based database for future analysis purposes.

  6. Radio interference and transient field from gas-insulated substations

    International Nuclear Information System (INIS)

    Harvey, S.M.; Wong, P.S.; Balma, P.M.

    1995-01-01

    Gas-insulated substations (GIS), owing to their compact nature, offer an attractive alternative to conventional substations in areas where space is limited, such as in urban areas. Consequently, it is important to address the issue of environmental conditions within the substation and in the surrounding areas. This paper reports the result of radio interference (RI) and transient field measurements at two GIS in Ontario, Canada. For comparison with RI levels taken at the GIS, RI levels outside two hospitals in the Toronto area were also measured. The transient field study covers electromagnetic interference (EMI) levels generated during switching operations, and includes measurements inside and outside the GIS. Measurements show that RI levels from the GIS were either below background levels, or contributed little to the background. RI levels outside the GIS and the hospitals were similar. Peak transient field values up to 580 V/m were measured inside the station building, and dropped to background values of 10 V/m at about 120 m from the station. The transient field (E) dropped off at a rate of 3/2 power with distance (d) from the air-insulated 115 kV bus, i.e. E ∝ d -1.5

  7. Preliminary design study of underground pumped hydro and compressed-air energy storage in hard rock. Volume 9: Design approaches. CAES. Appendix E: Electrical systems

    Science.gov (United States)

    1981-04-01

    The design approaches provided the basis for development of the preliminary plant design. The electrical systems described include the plant power system, switchyard and electrical motor starting system. The design approaches presented are based on the design criteria presented in the Project Design criteria - CAES. Selection of the preferred approach reflect the Task 3 study results and conform to the greatest extent possible with PEPCO's standard practices.

  8. Touch and step potential analysis at 23.9kV to 4.16kV & 13.8kV to 4.16kV distribution substations with pad-mounted transformers, floating grounds, and other exposed ungrounded metal bodies using WinIGS

    Science.gov (United States)

    Guzman, David G.

    An electrical substation is composed of various subsystems that allow for the effective and safe operation of the power grid. One of the subsystems integrating a conventional substation is defined as the ground grid system. This system allows for the effective operation of the power grid and all the electrical equipment connected to it by providing a ground potential reference, commonly known as the system ground. In addition, the ground grid system provides safety to the workers and the public transiting inside or living nearby a substation by reducing the step and touch potential (or voltage) levels present during a system fault. In today's utility industry practices there is an increasing trend for using pad-mounted electrical equipment for substation applications in an effort to construct new or upgrade existing electrical facilities inside limited property spaces. This thesis work presents an analysis for the effects of touch and step voltages at existing distribution substations where 23.9kV to 4.16kV & 13.8kV to 4.16kV pad-mounted transformers and other pad-mounted switchgear was installed to replace the traditional station class equipment. Moreover, this study will expose modeling techniques employed to define and determine the effects of floating grounds and other exposed metal bodies inside or surrounding these substations using WinIGS; this is in an effort to determine any risks of electric shock associated with this type of installations. The results presented in this work are intended to verify the requirements for the ground grid analysis and design for 4.16kV distribution substations with pad-mounted equipment in order to prevent dangerous step and touch voltage levels appearing at these sites during system faults; and ultimately prevent exposing individuals to the risk of an electric shock.

  9. THE SIMULATION RESULTS OF VARIOUS MODES OF TRACTION SUBSTATIONS OF DC

    Directory of Open Access Journals (Sweden)

    P. D. Andrienko

    2008-02-01

    Full Text Available The model of direct current traction substation, with the subsequent carrying out on this model the research of electromagnetic processes on the substation in a mode of recuperation with energy absorption devices for inclusion of which contactless switches are used is developed. The modeling has allowed to estimate character of electromagnetic processes occurring on the traction substation at work of the absorbing device with contactless switches and to optimize the processes.

  10. VT VEC Primary Overhead and Underground Distribution Lines

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) Vermont Electric Cooperative, Inc. (VEC) Primary Overhead and Underground Distribution Lines. VEC’s Distribution lines were drawn from pole to...

  11. Application of computational dosimetry studies to assess electromagnetic fields exposure in the vicinity of transmission lines and power substations

    International Nuclear Information System (INIS)

    Domingues, Luis A.M.C.; Cruz, Rafael M.; Neto, Athanasio Mpalatinos; Barbosa, Carlos R. Nunez

    2008-01-01

    Full text: This paper presents a methodological approach to assess exposure to ELF EMF's from transmission lines (TL's) and power substations (SE's), in order to verify their compliance to International Standards, such as ICNIRP and IEEE. In order to calculate the fields/currents induced inside the body which are used to verify compliance to the basic restrictions established on those Standards, a chain of calculation tools is established, in order to: Determine electric and magnetic fields produced by transmission lines/substations (magnitudes and phase angles at every point in space surrounding the installation); Establish an accurate model (FEM/FDM) for an human body submitted to the EMFs; Assign electric (permittivity and conductivity) characteristics to body tissues. A specific research intended to measure those parameters on living body tissues is mentioned, as an alternative to the general use of values found on the literature based on measurements made on dead bodies; Use the above calculation tools in order to determine the fields and currents induced inside bodies, by the applied external fields, at each point in space, for both general public and occupational exposure situations. Finally an application of this methodology to a practical case where the construction of an Urban Power Substation was under analysis on Public Hearings is presented. The analysis of the original design concept, as well as the proposed design improvements, intended to lower public exposure to EMF's are presented. The case of occupational exposure concerning workers on live line conditions is also analysed, and alternatives to reduce exposure on this case are proposed. (author)

  12. Underground storage tanks

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Environmental contamination from leaking underground storage tanks poses a significant threat to human health and the environment. An estimated five to six million underground storage tanks containing hazardous substances or petroleum products are in use in the US. Originally placed underground as a fire prevention measure, these tanks have substantially reduced the damages from stored flammable liquids. However, an estimated 400,000 underground tanks are thought to be leaking now, and many more will begin to leak in the near future. Products released from these leaking tanks can threaten groundwater supplies, damage sewer lines and buried cables, poison crops, and lead to fires and explosions. As required by the Hazardous and Solid Waste Amendments (HSWA), the EPA has been developing a comprehensive regulatory program for underground storage tanks. The EPA proposed three sets of regulations pertaining to underground tanks. The first addressed technical requirements for petroleum and hazardous substance tanks, including new tank performance standards, release detection, release reporting and investigation, corrective action, and tank closure. The second proposed regulation addresses financial responsibility requirements for underground petroleum tanks. The third addressed standards for approval of state tank programs

  13. [Evaluation of reports on environmental measurements of electromagnetic fields generated by high voltage transmission lines and substations].

    Science.gov (United States)

    Szuba, Marek

    2007-01-01

    This paper presents some situations, in which measurements of electromagnetic fields generated by transmission lines and substations should be performed. The range of measurements may differ, but maximum values of electric and magnetic fields and flux density must be identified in all situations. The area with electric field exceeding 1 kV/m should be identified as well. The author also presents basic requirements to be met by the measurement technique. These requirements are specified according to the national standard. Special attention should be paid to the identification of the spatial distribution of electric field and flux density generated in the vicinity of high voltage transmission lines. To verify the measurement results, it is necessary to calculate the distribution of both aforesaid field components. For environmental protection purposes, it is also proposed that the report should include measurements of electromagnetic fields of 50 Hz along with calculated results presented in tables and diagrams.

  14. Design Optimization of a Natural Gas Substation with Intensification of the Energy Cycle

    Directory of Open Access Journals (Sweden)

    Arcangelo Pellegrino

    2010-01-01

    Full Text Available Natural gas is currently the natural substitute of petroleum as an energy source, since the foreseen ending up of this latter in the next decades. As a matter of fact, natural gas is easier to handle, less dangerous to be transported, somehow environmentally more friendly. The gas ducts operate with large flow rates over very long distances at high pressures, which are usually lowered in proximity of the final substations by lamination valves which, in fact, dissipate energy. However, a careful management of the pressure reduction may allow an energy recovery while using the gas expansion to operate a turbine. In this case, gas must be preheated to compensate for the energy required by the expansion. A proper control of all the parameters involved becomes crucial to an intelligent use of these resources. In this paper, the possibility of using a pre-heating system has been examined as a way to intensify the energy cycle in an expansion substation of the city gas network. Fuzzy logic has been used to optimize the natural gas expansion in a turbine to produce electrical energy. A fuzzy system has been designed and realized to control the whole process of gas expansion, from the gas pre-heating to the pressure reduction. The system operates over the whole year, accounting for the pressure, temperature, and gas flow rate variations experienced in the gas line. The exit values of the latter and the inlet value of the gas pressure are selected as input variables, being the output variable the temperature of the pre-heating water at the heat exchanger inlet.

  15. The underground macroeconomics

    Directory of Open Access Journals (Sweden)

    Marin Dinu

    2013-01-01

    Full Text Available Like Physics, which cannot yet explain 96% of the substance in the Universe, so is Economics, unprepared to understand and to offer a rational explicative model to the underground economy.

  16. The contribution of local distribution substations and associated area distribution system to personal exposure to power frequency magnetic fields.

    Science.gov (United States)

    Grainger, P; Preece, A W

    2000-12-01

    A number of epidemiological studies has shown a significant correlation between wire coding, magnetic fields and childhood cancer, although a more recent study has not [McBride et al. (1999) Am. J. Epidemiol. 149 (9), 831-842]. In the UK there is currently no equivalent to wire-codes and there is some uncertainty about the extent to which the UK medium-voltage electricity distribution systems contribute to personal exposure and how this compares with US overhead supply systems. Studies on four different area types were carried out to measure magnetic field intensities from typical electricity supply utility substations and cabling in the vicinity of domestic housing. Typically at distances of two metres from the substations mean magnetic field intensities were 20 nano teslas (nT) or less, increasing to 0.98 microT or less at the closest public access point. The mean magnetic field exposure level sampled around the four main test areas varied between 0.012 and 0.27 microT increasing to 0.30-0.80 microT at road junctions.

  17. Orpheus in the Underground

    Directory of Open Access Journals (Sweden)

    Puskás Dániel

    2015-12-01

    Full Text Available In my study I deal with descents to the underworld and hell in literature in the 20th century and in contemporary literature. I will focus on modem literary reinterpretations of the myth of Orpheus, starting with Rilke’s Orpheus. Eurydice. Hermes. In Seamus Heaney’s The Underground. in the Hungarian Istvan Baka’s Descending to the Underground of Moscow and in Czesław Miłosz’s Orpheus and Eurydice underworld appears as underground, similarly to the contemporary Hungarian János Térey’s play entitled Jeramiah. where underground will also be a metaphorical underworld which is populated with the ghosts of the famous deceased people of Debrecen, and finally, in Péter Kárpáti’s Everywoman the grave of the final scene of the medieval Everyman will be replaced with a contemporary underground station. I analyse how an underground station could be parallel with the underworld and I deal with the role of musicality and sounds in the literary works based on the myth of Orpheus.

  18. 77 FR 52053 - Notice of Availability of the Record of Decision for San Diego Gas and Electric's East County...

    Science.gov (United States)

    2012-08-28

    ... DEPARTMENT OF THE INTERIOR Bureau of Land Management [CACA-51625, LLCAD07000, L51010000, ER0000, LVRWB10B3800] Notice of Availability of the Record of Decision for San Diego Gas and Electric's East County...&E filed right-of-way (ROW) application CACA-51625 for the ECO Substation Project. The ECO Substation...

  19. Functional Sub-states by High-pressure Macromolecular Crystallography.

    Science.gov (United States)

    Dhaussy, Anne-Claire; Girard, Eric

    2015-01-01

    At the molecular level, high-pressure perturbation is of particular interest for biological studies as it allows trapping conformational substates. Moreover, within the context of high-pressure adaptation of deep-sea organisms, it allows to decipher the molecular determinants of piezophily. To provide an accurate description of structural changes produced by pressure in a macromolecular system, developments have been made to adapt macromolecular crystallography to high-pressure studies. The present chapter is an overview of results obtained so far using high-pressure macromolecular techniques, from nucleic acids to virus capsid through monomeric as well as multimeric proteins.

  20. 30 CFR 77.811 - Movement of portable substations and transformers.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Movement of portable substations and transformers. 77.811 Section 77.811 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... and transformers. Portable substations and transformers shall be deenergized before they are moved...

  1. optimization design of ground grid mesh of 132/33kv substation

    African Journals Online (AJOL)

    user

    determine the ground grid mesh parameters, step & touch voltages, horizontal and vertical number of conductors, vertical numbers of rods, and final substation Resistance. Etap 12.60 software is used for the analysis. Firstly, expected maximum short circuit current of OHIA 132/33kV substation is determined. Secondly ...

  2. Simulation study on the lightning overvoltage invasion control transformer intelligent substation

    Science.gov (United States)

    Xi, Chuyan; Hao, Jie; Zhang, Ying

    2018-04-01

    By simulating lightning on substation line of one intelligent substation, research the influence of different lightning points on lightning invasion wave overvoltage, and the necessity of arrester for the main transformer. The results show, in a certain lightning protection measures, the installation of arrester nearby the main transformer can effectively reduce the overvoltage value of bus and the main transformer [1].

  3. THE MINIMALIZATION OF FILTER EQUIPMENT FOR TRACTION SUBSTATIONS USING BOOSTER CONVERTER

    Directory of Open Access Journals (Sweden)

    Yu. P. Goncharov

    2008-12-01

    Full Text Available The structure of traction substation 3,2 kV DC power source is considered. It is shown that the output filter choke of traction substation with voltage added converter may be excluded. A dynamic model of voltage added converter is developed, its features, as an active filter, are described.

  4. Optimization design of ground grid mesh of 132/33kv substation ...

    African Journals Online (AJOL)

    33kV substation. Ground grid mesh is made up of horizontal and vertical conductors connected with vertical rods buried under substation ground. The function of this structure is to effectively dissipate extremely high current generated in the ...

  5. An application of data mining in district heating substations for improving energy performance

    Science.gov (United States)

    Xue, Puning; Zhou, Zhigang; Chen, Xin; Liu, Jing

    2017-11-01

    Automatic meter reading system is capable of collecting and storing a huge number of district heating (DH) data. However, the data obtained are rarely fully utilized. Data mining is a promising technology to discover potential interesting knowledge from vast data. This paper applies data mining methods to analyse the massive data for improving energy performance of DH substation. The technical approach contains three steps: data selection, cluster analysis and association rule mining (ARM). Two-heating-season data of a substation are used for case study. Cluster analysis identifies six distinct heating patterns based on the primary heat of the substation. ARM reveals that secondary pressure difference and secondary flow rate have a strong correlation. Using the discovered rules, a fault occurring in remote flow meter installed at secondary network is detected accurately. The application demonstrates that data mining techniques can effectively extrapolate potential useful knowledge to better understand substation operation strategies and improve substation energy performance.

  6. Decentralized substations for low-temperature district heating with no Legionella risk, and low return temperatures

    DEFF Research Database (Denmark)

    Yang, Xiaochen; Li, Hongwei; Svendsen, Svend

    2016-01-01

    with domestic hot water (DHW) circulation. In this study, a system with decentralized substations was analysed as a solution to this problem. Furthermore, a modification for the decentralized substation system were proposed in order to reduce the average return temperature. Models of conventional system...... with medium-temperature district heating, decentralized substation system with LTDH, and innovative decentralized substation system with LTDH were built based on the information of a case building. The annual distribution heat loss and the operating costs of the three scenarios were calculated and compared....... From the results, realizing LTDH by the decentralized substation unit, 30% of the annual distribution heat loss inside the building can be saved compared to a conventional system with medium-temperature district heating. Replacing the bypass pipe with an in-line supply pipe and a heat pump...

  7. IEC 61850: integrating substation automation into the power plant control system; IEC 61850: Integration der Schaltanlagenautomatisierung in die Kraftwerksleittechnik

    Energy Technology Data Exchange (ETDEWEB)

    Orth, J. [ABB AG, Mannheim (Germany)

    2008-07-01

    The new communication standard IEC 61850 has been developed in the substation automation domain and was released 2004 as a worldwide standard. Meanwhile IEC 61850 is already established in many substation automation markets. The paper discusses the implementation of IEC 61850 integrating process control and substation automation into one consistent system in a power plant. (orig.)

  8. The efficient use of the electric energy in underground water pumping systems in the Bajio (lowlands); El uso eficiente de la energia electrica en los sistemas de bombeo de agua subterranea en el Bajio

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, E. [Irapuato (Mexico)

    1997-12-31

    In the Bajio region the underground water is the main source of drinking water and approximately constitutes 50% of the water used for agricultural purposes. From the energy standpoint pumping represents 33% of the electricity consumption and a wastage of 35% is estimated. In order to take care of this problem a methodology was designed for an energetic appraisal of the well pumping systems, with the basic objective of knowing the electro-mechanical efficiency of the equipment and the efficiency of the auxiliary equipment and the well hydraulic response. The analysis of the results of 221 diagnoses performed demonstrates the profitability of the equipment rehabilitation, plus other advantages of collective character . [Espanol] En la region del Bajio, el agua subterranea constituye la principal fuente de agua potable y aproximadamente, el 50% del agua para riego agricola; desde el punto de vista energetico, el bombeo de ella representa el 33% de la electricidad que se consume y se estima un desperdicio del 35%. Para atender la problematica, se diseno una metodologia para un diagnostico energetico de los sistemas de bombeo de los pozos, con el objetivo basico de conocer la eficiencia electro-mecanica de los equipos, el comportamiento de los equipos auxiliares y la capacidad de respuesta hidraulica del pozo. El analisis de los resultados de 221 diagnosticos realizados, pone de manifiesto la redituabilidad de la rehabilitacion de los equipos, ademas de otras ventajas de caracter colectivo.

  9. Exposure to magnetic field harmonics in the vicinity of indoor distribution substations.

    Science.gov (United States)

    Keikko, Tommi; Seesvuori, Reino; Valkealahti, Seppo

    2006-12-01

    Due to possible health effects of electric and magnetic fields, the International Commission on Non-Ionizing Radiation Protection (ICNIRP) published in 1998 guidelines in which upper limits for public and occupational exposure were established. The guidelines are widely referenced by the EU directive of 2004. Thus, in Europe we have passed the time for discussion about the possible biological effects of magnetic fields and the duration of exposure to be allowed. Furthermore, in 2003, ICNIRP expanded their guidelines by taking into account the harmonic components of the magnetic field with phase angles. This statement has not been referenced widely. The aim of this study was to investigate magnetic fields, especially the harmonic components, in electric distribution (20/0.4 kV) substations from the public and occupational exposure point of view. The main finding is that the harmonic content of the magnetic field can dominate the exposure. The harmonic contents analyzed following the original ICNIRP guidelines varied between 49 and 74%. When taking into account the magnetic field phase angles, the harmonic content was only between 16 and 62%. By taking into account only the amplitudes of the harmonic components, ignoring their phase angles, the content of harmonic components is overestimated, on the average, by 30%.

  10. Electric engineering summary

    International Nuclear Information System (INIS)

    Kang, Sing Eun; Park, Seong Taek; Lim, Yong Un

    1975-03-01

    This book is made up six parts, which deals with circuit theory about sinusoidal alternating current, basic current circuit, wave power, distorted wave, two terminal network, distributed circuit, laplace transformation and transfer function, power engineering on line, failure analysis transmission of line, substation and protection device and hydroelectric power plant, electricity machine like DC machine, electric transformer, induction machine and rectifier, electromagnetic on dielectric substance current, electromagnetic, electricity application like lighting engineering, heat transfer and electricity chemistry, industry, industry math with integer, rational number, factorization, matrix and differential.

  11. NEW APPROACHES TO MAINTENANCE AND REPAIRING OF THE TRACTION SUBSTATIONS EQUIPMENT ON ELECTRIFIED RAILWAYS ON THE BASIS OF SMART-TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    O. O. Matusevich

    2014-06-01

    Full Text Available Purpose. At the stage of modernization and reconstruction of electrified railroads in Ukraine one should take into account the innovative development level of all electric supply subjects on the basis of advanced technologies. Determination the ways to increase the power supply reliability of electrified railways and reducing the accidents of the traction substation power equipment (TS. Methodology. For attainment a goal it’s studied the international experience on qualitative power supply of the electrical railways at the basis of the ideology of Smart Grid. It’s conducted a research of the major methods of technical servicing, repairing (TS and R and diagnostics the traction substation devices of electrified railways. Findings. As a result of research it was concluded that the basis of the new methods of maintenance and repearing is analysis of the risks of operation of the weared equipment or equipment with some defects (maintenance of equipment on the basis of the actual technical condition. It’s also concluded that the conceptual definitions of Smart Grid point to the important role of smart grid technology to the economic development of the electrical system. Significant world experience of maintenance and repairing at the basis of the actual technical state shows the following general assessment of the effectiveness of this method: reducing maintenance costs by 75%, reducing the number of services up to 50%, reduction the number of failures by 70% in the first year. Originality. As a research and improvement result of the maintenance and repairing system of traction substations, the author has proposed the concept of maintenance and repairing intelligent system, monitoring and diagnostic of technical process equipment. The basic components of the system are proposed. It’s proposed a maintenance of the equipment of traction substation at the actual technical state with better resource parameters. In the normative document for

  12. Dynamic underground stripping. Innovative technology summary report

    International Nuclear Information System (INIS)

    1995-04-01

    Dynamic Underground Stripping (DUS) is a combination of technologies targeted to remediate soil and ground water contaminated with organic compounds. DUS is effective both above and below the water table and is especially well suited for sites with interbedded sand and clay layers. The main technologies comprising DUS are steam injection at the periphery of a contaminated area to heat permeable subsurface areas, vaporize volatile compounds bound to the soil, and drive contaminants to centrally located vacuum extraction wells; electrical heating of less permeable sediments to vaporize contaminants and drive them into the steam zone; and underground imaging such as Electrical Resistance Tomography to delineate heated areas to ensure total cleanup and process control. A full-scale demonstration was conducted on a gasoline spill site at Lawrence Livermore National Laboratory in Livermore, California from November 1992 through December 1993

  13. Underground Storage Tanks in Iowa

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Underground storage tank (UST) sites which store petroleum in Iowa. Includes sites which have been reported to DNR, and have active or removed underground storage...

  14. Subsidence Induced by Underground Extraction

    Science.gov (United States)

    Galloway, Devin L.

    2016-01-01

    Subsidence induced by underground extraction is a class of human-induced (anthropogenic) land subsidence that principally is caused by the withdrawal of subsurface fluids (groundwater, oil, and gas) or by the underground mining of coal and other minerals.

  15. Underground Coal Mining

    Science.gov (United States)

    Hill, G. M.

    1980-01-01

    Computer program models coal-mining production, equipment failure and equipment repair. Underground mine is represented as collection of work stations requiring service by production and repair crews alternately. Model projects equipment availability and productivity, and indicates proper balance of labor and equipment. Program is in FORTRAN IV for batch execution; it has been implemented on UNIVAC 1108.

  16. Underground mining operation supports

    Energy Technology Data Exchange (ETDEWEB)

    Khusid, M.B.; Kozel, A.M.

    1980-12-10

    Underground mining operation supports include the supporting layer surrounded by a cylindrical jacket of cemented rock. To decrease the loss of support material due to the decreasing rock pressure on the supporting layer, the cylindrical jacket of cemented rock has an uncemented layer inside, dividing it into 2 concentric cylindrical parts.

  17. Algorithms for the evaluation of the reliability of networks and substations; Algoritmos para evaluar la confiabilidad de redes y subestaciones electricas

    Energy Technology Data Exchange (ETDEWEB)

    Vega Ortiz, Miguel [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    Two algorithms are presented, one for analyzing the reliability of networks and another one to analyzing the reliability of electrical substations. The algorithms model a network or a substation by means of a graph and determine all the exits, of up to third degree, which isolates the load points. The algorithm that is used for the network analysis, is the one of p-cuts and in the case of the substations it is the one of minimum ways, for later, from these minimum p-cuts and of the minimum ways, obtains the minimum cuts. These minimum cuts are evaluated with the approximate method and give as a result the system reliability and of each one of the components that have been modeled. At the end some examples and results obtained are shown. As case of study, the algorithm is applied to two substations arrangements and to a network of industrial distribution, but it is possible to be applied to transmission and distribution networks. [Spanish] Se presentan dos algoritmos, uno para analizar la confiabilidad de redes y otro para analizar la confiabilidad de subestaciones electricas. Los algoritmos modelan una red o una subestacion por medio de un grafo y determinan todas las salidas, de hasta tercer grado, que aislan los puntos de carga. El algoritmo que se utiliza para el analisis de redes, es el de p-cortes y en el caso de las subestaciones es el de caminos minimos, para despues, a partir de estos p-cortes minimos y de los caminos minimos, obtener los cortes minimos. Estos cortes minimos se evaluan con el metodo aproximado y dan como resultado la confiabilidad del sistema y de cada una de las componentes que se hayan modelado. Al final se muestran algunos ejemplos y resultados obtenidos. Como caso de estudio, el algoritmo se aplica a dos arreglos de subestaciones y a una red de distribucion industrial, pero se puede aplicar a redes de transmision y de distribucion.

  18. Characterization of ferroresonant modes in HV substation with CB grading capacitors

    Energy Technology Data Exchange (ETDEWEB)

    Val Escudero, M. [ESB International, 19/21 Stephen Court, Stephen' s, Green, Dublin (Ireland); Dudurych, I. [TSO EirGrid, Ireland, Power System Operations, 27, Lower Fitzwilliam Street, Dublin 2 (Ireland); Redfern, M.A. [Department of Electrical Engineering, Bath University, Claverton Down, Bath (United Kingdom)

    2007-09-15

    This paper reports a ferroresonant experience involving inductive voltage transformers (VT's) in a 400 kV substation equipped with circuit breaker grading capacitors. Field measurements are presented and compared with ATP/EMTP simulation results, showing very good agreement. A parametric analysis has been performed to investigate the effect of the substation capacitance on the occurrence of ferroresonance. Fundamental frequency and sub-harmonic ferroresonant modes have been identified and compiled in a bifurcation diagram. The methodology presented can be used to create risk maps of avoidable switching operations or substation configurations. (author)

  19. Expert systems in power substation operation and control

    Energy Technology Data Exchange (ETDEWEB)

    Ribeiro, Guilherme Moutinho; Lambert-Torres, Germano; Silva, Alexandre P. Alves da [Escola Federal de Engenharia de Itajuba, MG (Brazil)

    1994-12-31

    With digital technology being increasingly adopted in power substations (SE), perspectives are created for integration of supervision, control and protection systems in addition to making its process automation feasible. Once a SE is digitalized, the systems which previously were implemented physically will be able to be implemented by means of computer programs (software), allowing the expansion of its scope of operation. Studies and research performed at the international level have pointed to the utilization of Expert Systems (ES) as a more suitable alternative for representation and solution of the operation and control problems, especially those which do not have an established theory, which are provided with diagnosis characteristics and that associate themselves with fuzzy data and information. (author) 4 refs., 3 figs.

  20. A triggered co-ordinating gap for metalclad substations

    Energy Technology Data Exchange (ETDEWEB)

    Hampton, B.F.; Meats, R.J.

    1978-01-01

    A triggered sphere gap in SF/sup 6/ was developed to provide protection against switching overvoltages in metalclad substations. The trigger is activated when the voltage across the gap reaches a predetermined level, irrespective of its waveshape or polarity. Complete breakdown of the gap follows in 3 microsec due to delays in the triggering circuit, but there are prospects of reducing this. Protection against lightning surges at the basic insulation level is ensured by self-breakdown on the front of the wave. The protective level of the gap is well defined, the difference between the guaranteed withstand and flashover voltages being less than 2%. Since the gap must be replaced after each flashover, it should be used only where the probability of it operating is low. In those situations it could be considered as a small, low-cost alternative to a surge arrester.

  1. The possible negative consequences of underground dam and reservoir construction and operation in coastal karst areas: an example of the hydro-electric power plant (HEPP) Ombla near Dubrovnik (Croatia)

    Science.gov (United States)

    Roje-Bonacci, T.; Bonacci, O.

    2013-08-01

    The Ombla Spring represents a typical abundant coastal karst spring located in the vicinity of the town of Dubrovnik (Croatia). Its outlet is at an altitude of 2.5 m above sea level (m a.s.l.) and the water from it immediately flows into the Adriatic Sea. The minimum and maximum measured discharges are 3.96 m3 s-1 and 117 m3 s-1, respectively. The Trebišnjica River traverses through its catchment. The mean annual discharge, after the canalization of over 60 km of its watercourse with spray concrete (in the time span 1981-2011), is 24.05 m3 s-1. Before massive civil engineering work which took place during 1968-1980, the mean annual discharge was 28.35 m3 s-1. There is a project for construction of the hydro-electric power plant (HEPP) Ombla, which will exclusively use groundwater from the Ombla Spring karst aquifer. The underground dam will be constructed about 200 m behind the existing karst spring outflow in the karst massif, by injecting a grout curtain. The top of the grout curtain is planned to be at an altitude of 130 m a.s.l. This karst system is complex, sensitive, vulnerable and ecologically extremely valuable. The grout curtain, as well as the HEPP Ombla development, could lead to extremely dangerous technical and environmental consequences. In this paper some probable, negative consequences of the HEPP Ombla construction and development are explained. The HEPP Ombla could result in many large and hard-to-predict negative consequences which are specific for this particular HEPP, for example (1) severe spring discharge change; (2) unpredictable regional groundwater redistribution; (3) threatening of endemic fauna; (4) induced seismicity; (5) induced sinkholes; (6) occurrence of landslides; (7) conflict regarding internationally shared karst aquifers; (8) intensification of karst flash floods; (9) sea water intrusion in coastal karst aquifer; etc.

  2. Simulation of the Static VAR Compensator Culiacan Three Substation for the Analysis of Transients

    Directory of Open Access Journals (Sweden)

    Coronel-Mercado Luis Enrique

    2013-06-01

    Full Text Available Since its emergence in the late 60’s the FACTS (Flexible AC Transmission Systems have been and continue to be studied and implemented in all electrical networks around the world, becoming an essential element for stability, control and maximum exploitation of thereof. One of the most used FACTS devices is the Static VAR Compensator or SVC. In this work, the modeling in Simulink of the Static VAR Compensator installed at the substation Culiacán Tres (CUT belonging to CFE is presented. The SVC is the ability of ±100 MVAR and ABB brand. The modeling was performed to visually program in detail the different subsystems in Simulink such as the timing unit, the TSC (thyristor switched capacitor, TCR (thyristor controlled reactors, filters of the 5th and the 7th harmonic, the transformer bank, the control unit, distribution unit and the measurement unit. Data for major components were taken from data sheet and equipment manuals. ASPEN software was used in order to obtain Thevenin equivalent of the EPS to connect to them the SVC model to test the step and three-phase short circuit. The results of these tests were compared with test results of commissioning of the SVC.

  3. Perspective loads of transformer substations at development of urban power supply systems

    Directory of Open Access Journals (Sweden)

    Svetlana Guseva

    2012-06-01

    Full Text Available In work the system approach to formation of the urban power supply system is given. The hierarchical structure of the construction, voltage levels and load densities is considered. The mathematical and geometrical modeling of service areas for transformer substations of diff erent voltage is fulfi lled. Determination of perspective loads of transformer substations is given. The method of graphic placement of transformer substations in the city territory for new substations at existing structure of networks is off ered. The calculation program Microsoft EXCEL and the graphic program AutoCad are used for realization of method. The method allows fi nding a rational decision for the development of urban power supply system on the beginning design stages in conditions of the information uncertainty.

  4. Harmonic Characteristics of Rectifier Substations and Their Impact on Audio Frequency Track Circuits

    Science.gov (United States)

    1982-05-01

    This report describes the basic operation of substation rectifier equipment and the modes of possible interference with audio frequency track circuits used for train detection, cab signalling, and vehicle speed control. It also includes methods of es...

  5. The environmental evaluation of substation based on the fuzzy analytic hierarchy process

    Science.gov (United States)

    Qian, Wenxiao; Zuo, Xiujiang; Chen, Yuandong; Ye, Ming; Fang, Zhankai; Yang, Fan

    2018-02-01

    This paper studies on the different influences on the environment of the substations and puts forward an index system of environmental protection through the fuzzy analytic hierarchy process. A comprehensive environmental evaluation on a substation is carried out through investigation and measurement of the current environmental factors, and the statistical data has validated the effectiveness and feasibility of this evaluation index system. The results indicate that the proposed model has high efficiency.

  6. Filtration of harmonics in traction transformer substations, positive side effects on the additional harmonics

    OpenAIRE

    Kolář, Václav; Kocman, Stanislav

    2011-01-01

    The article deals with harmonics filtration in railway traction transformer substations. In traction transforms substations in the Czech Republic there are filters of 3rd and 5th harmonics. The article discuses side effect of these filters – suppression of additional harmonics. The article is based on measurement and simulation results. Przedstawiono metodę filtracji harmonicznych w trakcyjnej podstacji transformatorowej. Przedfstawiono wyniki symulacji i pomiarów. Web of Science ...

  7. Nuclear plant undergrounding

    International Nuclear Information System (INIS)

    Brown, R.C.; Bastidas, C.P.

    1978-01-01

    Under Section 25524.3 of the Public Resources Code, the California Energy Resources Conservation and Development Commission (CERCDC) was directed to study ''the necessity for '' and the effectiveness and economic feasibility of undergrounding and berm containment of nuclear reactors. The author discusses the basis for the study, the Sargent and Lundy (S and L) involvement in the study, and the final conclusions reached by S and L

  8. Monitoring underground movements

    CERN Multimedia

    Antonella Del Rosso

    2015-01-01

    On 16 September 2015 at 22:54:33 (UTC), an 8.3-magnitude earthquake struck off the coast of Chile. 11,650 km away, at CERN, a new-generation instrument – the Precision Laser Inclinometer (PLI) – recorded the extreme event. The PLI is being tested by a JINR/CERN/ATLAS team to measure the movements of underground structures and detectors.   The Precision Laser Inclinometer during assembly. The instrument has proven very accurate when taking measurements of the movements of underground structures at CERN.    The Precision Laser Inclinometer is an extremely sensitive device capable of monitoring ground angular oscillations in a frequency range of 0.001-1 Hz with a precision of 10-10 rad/Hz1/2. The instrument is currently installed in one of the old ISR transfer tunnels (TT1) built in 1970. However, its final destination could be the ATLAS cavern, where it would measure and monitor the fine movements of the underground structures, which can affect the precise posi...

  9. Electricity

    Indian Academy of Sciences (India)

    AC power generation, its transmission and distribution. The well known observations made by Oersted that an electric current produces a magnetic field led a number of researchers to investigate whether the converse was true i.e. whether electric current can be produced from a magnetic field. Michael Faraday of England ...

  10. Development of 3 D Electric Field Analysis Program under Power System Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Myung, S. H.; Lee, K. C.; Lee, J. B.; Ha, T. H. [Korea Electrotechnology Research Institute, Changwon (Korea, Republic of)

    1996-12-01

    Recently, as the effects of electric fields on animals, human beings and sensitive equipment have been reported, the study on electric fields has become more important. Transmission lines and substation among power facilities are dominant parts related to electrical environment. Electric field analysis of transmission line has been made using image charge method or CSM since 1970`s, however electric field analysis in substation has been rarely studied due to the complexity of three dimensional evaluation of an electric field in substation. For the rather complicated and time-consuming three-dimensional electric field calculation in the vicinity of transmission lines and substations, this study proposes an effective numerical calculation method based on Charge Simulation Method(CSM). In order to represent non-uniform charge distribution on an electrode better, it is subdivided into small segments with linear charge density. Each segment with linear charge density can be easily represented by a generalized finite line type of charge whose expressions for potential and electric field were analytically derived and which was named {sup f}inite slant line charge in this study. As for the arrangement of small segments of a subdivided electrode, it has been found that unequally spaced arrangement method is superior to equally spaced one. In order to arrange segments fast and effectively, effective formulas were derived from multiple regression analysis of many simulations. The proposed method is applied to the electric field calculation around the transmission lines with significant change in direction and substation busbars. (author). refs., figs., tabs.

  11. Overview of electrical energy in September 2003; Apercu sur l'energie electrique en septembre 2003

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    exchanges recorded by RTE (contracts for access to international connections). Transmission network development (the following facilities were commissioned on the RTE network in September 2003): the 90 kV substation at Trevins, connected to the substation at Niort via a 5 km underground cable, for guaranteeing the security of electricity supply to the North-Eastern area of Niort; the 63 kV substation at Arnay Le Duc on the Cote d'Or, connected by an 18 km line to the main 63 kV Crugey-Vielmoulin artery, for relieving restrictions on the zone's HVA networks; a 170 MVA 225/90 kV transformer at the La Corbiere substation - replacing a 100 MVA transformer - for strengthening the EHV/HV supply to the Anjou region; a 90 kV/MV transformer at the Tilleul substation, to improve the quality of supply to the Evreux region.

  12. Environment Of Underground Water And Pollution

    Energy Technology Data Exchange (ETDEWEB)

    Han, Jeong Sang

    1998-02-15

    This book deals with environment of underground water and pollution, which introduces the role of underground water in hydrology, definition of related study of under water, the history of hydro-geology, basic conception of underground water such as origin of water, and hydrogeologic characteristic of aquifers, movement of underground water, hydrography of underground water and aquifer test analysis, change of an underground water level, and water balance analysis and development of underground water.

  13. Pervasive Electricity Distribution System

    Directory of Open Access Journals (Sweden)

    Muhammad Usman Tahir

    2017-06-01

    Full Text Available Now a days a country cannot become economically strong until and unless it has enough electrical power to fulfil industrial and domestic needs. Electrical power being the pillar of any country’s economy, needs to be used in an efficient way. The same step is taken here by proposing a new system for energy distribution from substation to consumer houses, also it monitors the consumer consumption and record data. Unlike traditional manual Electrical systems, pervasive electricity distribution system (PEDS introduces a fresh perspective to monitor the feeder line status at distribution and consumer level. In this system an effort is taken to address the issues of electricity theft, manual billing, online monitoring of electrical distribution system and automatic control of electrical distribution points. The project is designed using microcontroller and different sensors, its GUI is designed in Labview software.

  14. Change in Brooklyn and Queens: How New York?s Reforming the Energy Vision Program and Con Edison Are Reshaping Electric Distribution Planning

    Energy Technology Data Exchange (ETDEWEB)

    Coddington, Michael; Sciano, Damian; Fuller, Jason

    2017-03-01

    In response to this tremendous growth in both population and electricity demand, Con Edison estimates that its cost to expand the “traditional” Brooklyn-Queens grid will be in the neighborhood of US$1.2 billion—a relatively high number, even for New York City and Con Edison. The complexity of the city’s underground electrical system along with the difficulties of construction in a highly congested urban environment with infrastructure both above and below ground mean that the costs for transmission, substations, and secondary networks are significantly higher than those of a typical electric utility. The New York State Public Service Commission (PSC) is in the process revising its approach to acquiring and serving energy throughout the state of New York, and traditional expansion for this rather costly project was not likely to be approved. Instead, the PSC asked Con Edison to evaluate numerous alternatives. The PSC and Con Edison are now considering and adopting strategies that include renewable energy generation, demand response (DR), battery energy storage systems, fuel-cell distributed generation, combined heat and power, volt-volt ampere reactive (VAR) optimization (VVO), and a host of other innovative solutions that would both reduce electricity demand and transform how and when Con Edison’s consumers use electricity.

  15. Regulated underground storage tanks

    International Nuclear Information System (INIS)

    1992-06-01

    This guidance package is designed to assist DOE Field operations by providing thorough guidance on the underground storage tank (UST) regulations. [40 CFR 280]. The guidance uses tables, flowcharts, and checklists to provide a ''roadmap'' for DOE staff who are responsible for supervising UST operations. This package is tailored to address the issues facing DOE facilities. DOE staff should use this guidance as: An overview of the regulations for UST installation and operation; a comprehensive step-by-step guidance for the process of owning and operating an UST, from installation to closure; and a quick, ready-reference guide for any specific topic concerning UST ownership or operation

  16. Underground water stress release models

    Science.gov (United States)

    Li, Yong; Dang, Shenjun; Lü, Shaochuan

    2011-08-01

    The accumulation of tectonic stress may cause earthquakes at some epochs. However, in most cases, it leads to crustal deformations. Underground water level is a sensitive indication of the crustal deformations. We incorporate the information of the underground water level into the stress release models (SRM), and obtain the underground water stress release model (USRM). We apply USRM to the earthquakes occurred at Tangshan region. The analysis shows that the underground water stress release model outperforms both Poisson model and stress release model. Monte Carlo simulation shows that the simulated seismicity by USRM is very close to the real seismicity.

  17. Analysis of the applicability of DNP 3.0 (distributed network protocol) in protection, monitoring, control and automation systems of electric power plants and substations; Analise da aplicabilidade do DNP 3.0 (distributed network protocol) em sistemas de protecao, supervisao, controle e automacao de usinas e SEs

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Euro Pinto de; Lippmann Junior, Lourival; Klinguelfus, Mauro Cezar; Oliveira, William Lopes de [Companhia Paranaense de Energia (COPEL), Curitiba, PR (Brazil). LAC

    1995-12-31

    This article presents the analysis of the DNP 3.0 (Distributed Network Protocol) as a feasible alternative of a model to be used in the control and supervision systems communication in the electric power sector. According to the authors, the results of such analysis are very important once the communication record can be considered as a key-piece for the feasibility of general implementation of digital systems in automation, control, supervision and protection systems on the electric power sector 4 refs.; e-mail: william at lac.copel.br

  18. Daily peak electricity load forecasting in South Africa using a ...

    African Journals Online (AJOL)

    transmission substations, scheduling of startup times of peak stations, load flow analysis and power system security ... blackout. This NESO definition excludes the demand from people, companies, etc. who are willing (or unwilling) and able (or unable) to pay for electricity, but currently do not have access to electrical power.

  19. modeling and optimization of an electric power distribution network

    African Journals Online (AJOL)

    user

    possibilities of configurations that exist in the selection of network facilities. The electric distribution network expansion planning problem (EDNEPP) is to determine the optimal location and capacities of substations, and optimal feeders route paths which would provide electric power to a given set of load demand nodes at ...

  20. Going Underground in Singapore

    CERN Multimedia

    John Osborne (GS/SEM)

    2010-01-01

    Singapore has plans to build a massive Underground Science City (USC) housing R&D laboratories and IT data centres. A delegation involved in the planning to build the subterranean complex visited CERN on 18 October 2010 to learn from civil engineers and safety experts about how CERN plans and constructs its underground facilities.   The delegation from Singapore. The various bodies and corporations working on the USC project are currently studying the feasibility of constructing up to 40 caverns (60 m below ground) similar in size to an LHC experiment hall, in a similar type of rock. Civil engineering and geotechnical experts are calculating the maximum size of the cavern complex that can be safely built. The complex could one day accommodate between 3000 and 5000 workers on a daily basis, so typical issues of size and number of access shafts need to be carefully studied. At first glance, you might not think the LHC has much in common with the USC project; as Rolf Heuer pointed out: &ldq...

  1. Underground storage tank program

    International Nuclear Information System (INIS)

    Lewis, M.W.

    1994-01-01

    Underground storage tanks, UST'S, have become a major component of the Louisville District's Environmental Support Program. The District's Geotechnical and Environmental Engineering Branch has spear-headed an innovative effort to streamline the time, effort and expense for removal, replacement, upgrade and associated cleanup of USTs at military and civil work installations. This program, called Yank-A-Tank, creates generic state-wide contracts for removal, remediation, installation and upgrade of storage tanks for which individual delivery orders are written under the basic contract. The idea is to create a ''JOC type'' contract containing all the components of work necessary to remove, reinstall or upgrade an underground or above ground tank. The contract documents contain a set of generic specifications and unit price books in addition to the standard ''boiler plate'' information. Each contract requires conformance to the specific regulations for the state in which it is issued. The contractor's bid consists of a bid factor which in the multiplier used with the prices in the unit price book. The solicitation is issued as a Request for Proposal (RPP) which allows the government to select a contractor based on technical qualification an well as bid factor. Once the basic contract is awarded individual delivery orders addressing specific areas of work are scoped, negotiated and awarded an modifications to the original contract. The delivery orders utilize the prepriced components and the contractor's factor to determine the value of the work

  2. RP delves underground

    CERN Document Server

    Anaïs Schaeffer

    2011-01-01

    The LHC’s winter technical stop is rapidly approaching. As in past years, technical staff in their thousands will be flocking to the underground areas of the LHC and the Linac2, Booster, PS and SPS injectors. To make sure they are protected from ionising radiation, members of the Radiation Protection Group will perform an assessment of the levels of radioactivity in the tunnels as soon as the beams have stopped.   Members of the Radiation Protection Group with their precision instruments that measure radioactivity. At 7-00 a.m. on 8 December the LHC and all of the upstream accelerators will begin their technical stop. At 7-30 a.m., members of the Radiation Protection Group will enter the tunnel to perform a radiation mapping, necessary so that the numerous teams can do their work in complete safety. “Before we proceed underground, we always check first to make sure that the readings from the induced radioactivity monitors installed in the tunnels are all normal,&rdqu...

  3. Underground super highway

    International Nuclear Information System (INIS)

    Latimer, Cole

    2010-01-01

    Clear communication is key. And quality communications and information equipment is now, more than ever before, integral in mine development as the industry moves towards greater remote control and automation of machinery and mining processes. In an underground mine, access to communications and information equipment has often been limited due to thermal extremes, physical hazards and dangerous chemicals. On top of this, copper conductors that are often used for communication equipment do not operate as efficiently because of the excessive noise generated by mining equipment, and may also puse a safety hazard. However, the design of extremely rugged fibre optic cables is now enabling ten gigabit transmission links in places that were never before thought possible in mining. One place though, has still proved a challenge for the expansion of fibre optic net-works, and that is in an underground coal mine. Until now. Optical Cable Corporation (OCC) has developed the rugged tight buffered breakout fibre optic cables for transmission links in harsh mining environments. Working at depths of over 300 metres below ground, and having seen roof falls actually bury the cable between rocks and still, the cables are able to operate in a myriad of conditions

  4. Dynamic underground stripping demonstration project

    International Nuclear Information System (INIS)

    Newmark, R.L.

    1992-04-01

    LLNL is collaborating with the UC Berkeley College of Engineering to develop and demonstrate a system of thermal remediation techniques for rapid cleanup of localized underground spills. Called dynamic stripping to reflect the rapid and controllable nature of the process, it will combine steam injection, direct electrical heating, and tomographic geophysical imaging in a cleanup of the LLNL gasoline spill. In the first eight months of the project, a Clean Site engineering test was conducted to prove the field application of the techniques. Tests then began on the contaminated site in FY 1992. This report describes the work at the Clean Site, including design and performance criteria, test results, interpretations, and conclusions. We fielded 'a wide range of new designs and techniques, some successful and some not. In this document, we focus on results and performance, lessons learned, and design and operational changes recommended for work at the contaminated site. Each section focuses on a different aspect of the work and can be considered a self-contained contribution

  5. 30 CFR 75.1312 - Explosives and detonators in underground magazines.

    Science.gov (United States)

    2010-07-01

    ... Blasting § 75.1312 Explosives and detonators in underground magazines. (a) The quantity of explosives kept... roadways and any source of electric current; (2) Located out of the direct line of the forces from blasting... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Explosives and detonators in underground...

  6. Electric power industry in China

    Energy Technology Data Exchange (ETDEWEB)

    Zisheng Jiang [Ministry of Electric Power, Beijing (China). Bureau of Electric Power Machinery

    1995-07-01

    This document presents the status of the electric power in China, highlighting the following aspects: recent achievement, electricity increased sharing in the total energy consumption, technical economic indexes, nuclear power, renewable energy sources, rural electrification, transmission and power network, transmission lines and substations, present status and development trends for power network, regulation of power system dispatching, power system communication. The document also presents the future developing plan, approaching the outlook and strategy, development targets of the electric power industry and the administrative system reforming of the electric power industry.

  7. Power substation location selection using fuzzy analytic hierarchy process and PROMETHEE: A case study from Bangladesh

    International Nuclear Information System (INIS)

    Kabir, Golam; Sumi, Razia Sultana

    2014-01-01

    Electromagnetic radiations emanating from the high voltage lines and substations pose serious adverse health consequences to living beings. As a result, selection of power substation location is an important strategic decision-making problem for both public and private sectors. In general, many conflicting factors affect the appropriate substation location selection problem which adheres to uncertain and imprecise data. In this paper, a simple, systematic and logical scientific approach is structured to evaluate power substation location through integrating Fuzzy Analytical Hierarchy Process (FAHP) with the Preference Ranking Organization Method for Enrichment Evaluations (PROMETHEE). The proposed integrated approach provides more realistic and reliable results, and facilitates the decision-maker to handle multiple contradictory decision perspectives through eliminating the limitations of FAHP and PROMETHEE methods. To accredit the proposed model, it is implemented in a power substation location selection problem in Bangladesh. - Highlights: • Integrate the strengths and eliminate the limitations of FAHP and PROMETHEE. • Consider social, technological, economic, environmental, and site characteristics criteria. • Determine the weights of criteria and sub-criteria using FAHP. • Present both PROMETHEE I and PROMETHEE II ranking. • Enable graphical representation of the alternatives and criteria by GAIA plane

  8. Application of Service Oriented Architecture for Sensors and Actuators in District Heating Substations

    Science.gov (United States)

    Gustafsson, Jonas; Kyusakov, Rumen; Mäkitaavola, Henrik; Delsing, Jerker

    2014-01-01

    Hardwired sensor installations using proprietary protocols found in today's district heating substations limit the potential usability of the sensors in and around the substations. If sensor resources can be shared and re-used in a variety of applications, the cost of sensors and installation can be reduced, and their functionality and operability can be increased. In this paper, we present a new concept of district heating substation control and monitoring, where a service oriented architecture (SOA) is deployed in a wireless sensor network (WSN), which is integrated with the substation. IP-networking is exclusively used from sensor to server; hence, no middleware is needed for Internet integration. Further, by enabling thousands of sensors with SOA capabilities, a System of Systems approach can be applied. The results of this paper show that it is possible to utilize SOA solutions with heavily resource-constrained embedded devices in contexts where the real-time constrains are limited, such as in a district heating substation. PMID:25196165

  9. Toward a methodology for substate projections of registered nurse supply and demand in New York.

    Science.gov (United States)

    McGinnis, Sandra; Martiniano, Robert; Moore, Jean

    2010-01-01

    Even as concerns about nursing shortages continue nationwide and for individual states in the United States, there is little information on the impact of nursing shortages at substate levels, such as counties or groups of small counties. National and state level assessments can mask wide geographic variation in the distribution of registered nurses (RNs). The Center for Health Workforce Studies at the School of Public Health, University at Albany, developed a practical approach to projecting RN supply and demand at substate levels. The experimental model used in this research was adapted from a methodology utilized for the RN National Supply Model and National Demand Model developed by the Health Resources and Services Administration in the department of Health and Human Services to make RN supply and demand projections at the broader national and state levels. The Center's research highlighted the value of substate analyses in the identification of RN supply and demand gaps and found that supply and demand gaps vary greatly by region and within regions. This study also provided an in-depth understanding of the dynamics that drive substate labor markets for RNs as well as the need for substate analyses to help policymakers better allocate scarce resources to address nursing shortages.

  10. A novel PRP based deterministic, redundant and resilient IEC 61850 substation communication architecture

    Directory of Open Access Journals (Sweden)

    S.M. Suhail Hussain

    2016-09-01

    Full Text Available A secure, reliable, redundant, resilient, time critical, efficient and interoperable substation communication network (SCN is a prerequisite for a viable Substation Automation System (SAS. Due to emergence of IEC 61850 as a global standard for substation automation, the interoperability issues among components of substation from different vendors are resolved. The communication network must be fault tolerant and any substantial levels of disturbances should not affect the normal operation of the SAS. Due to digitization in SCN, the communication methodology is mainly focused on exchange of encrypted packet information. Failure of the communication mechanism, even for the order of milliseconds, would lead to catastrophic effects within the substation and also impacts the operation of grid, if not cleared timely. The high reliability of such a system is only possible under a redundant communication network which has a zero switchover time. Hence IEC 62439-3 based redundant protocols such as Parallel Redundancy Protocol (PRP recommended to be used in SCNs to achieve redundancy and seamless recovery in case of a failure. PRP based SAS along with detailed analysis of underlying process for implementing PRP protocol and its comparison with existing conventional protocols based SCN reported in literature is presented.

  11. Application of service oriented architecture for sensors and actuators in district heating substations.

    Science.gov (United States)

    Gustafsson, Jonas; Kyusakov, Rumen; Mäkitaavola, Henrik; Delsing, Jerker

    2014-08-21

    Hardwired sensor installations using proprietary protocols found in today's district heating substations limit the potential usability of the sensors in and around the substations. If sensor resources can be shared and re-used in a variety of applications, the cost of sensors and installation can be reduced, and their functionality and operability can be increased. In this paper, we present a new concept of district heating substation control and monitoring, where a service oriented architecture (SOA) is deployed in a wireless sensor network (WSN), which is integrated with the substation. IP-networking is exclusively used from sensor to server; hence, no middleware is needed for Internet integration. Further, by enabling thousands of sensors with SOA capabilities, a System of Systems approach can be applied. The results of this paper show that it is possible to utilize SOA solutions with heavily resource-constrained embedded devices in contexts where the real-time constrains are limited, such as in a district heating substation.

  12. The electrical functions automation at the COPEL - Brazilian Energy Company of Parana state; As funcoes eletricas automatizadas na COPEL - Companhia Paranense de Energia

    Energy Technology Data Exchange (ETDEWEB)

    Frisch, Arlenio Carneiro; Krauss, Carlos Cesar; Braga, Ciro de Carvalho; Marquez, Diogenes da Cunha; Parolin, Emerson Luis; Reggiani, Rodrigo; Kawano, Wilson [Companhia Paranaense de Energia (COPEL), Curitiba, PR (Brazil)

    2000-07-01

    The electrical functions are the set of computer programs developed for automation of the substation operator tasks executing automatically the operation routines, aiming at the minimizing the list of equipment to be operated by remote operator. Those processes are conducted by the substation computer executing the Supervision, Control and Data Acquisition - SCADA which is optional. The paper presents the automation system of substation and distribution network of COPEL - Electric Power of the Parana state, Brazil conceived and developed for conciliate low operation costs, installation and maintenance allied to the fault tolerance, modularity and functionality.

  13. Urban underground infrastructure mapping and assessment

    Science.gov (United States)

    Huston, Dryver; Xia, Tian; Zhang, Yu; Fan, Taian; Orfeo, Dan; Razinger, Jonathan

    2017-04-01

    This paper outlines and discusses a few associated details of a smart cities approach to the mapping and condition assessment of urban underground infrastructure. Underground utilities are critical infrastructure for all modern cities. They carry drinking water, storm water, sewage, natural gas, electric power, telecommunications, steam, etc. In most cities, the underground infrastructure reflects the growth and history of the city. Many components are aging, in unknown locations with congested configurations, and in unknown condition. The technique uses sensing and information technology to determine the state of infrastructure and provide it in an appropriate, timely and secure format for managers, planners and users. The sensors include ground penetrating radar and buried sensors for persistent sensing of localized conditions. Signal processing and pattern recognition techniques convert the data in information-laden databases for use in analytics, graphical presentations, metering and planning. The presented data are from construction of the St. Paul St. CCTA Bus Station Project in Burlington, VT; utility replacement sites in Winooski, VT; and laboratory tests of smart phone position registration and magnetic signaling. The soil conditions encountered are favorable for GPR sensing and make it possible to locate buried pipes and soil layers. The present state of the art is that the data collection and processing procedures are manual and somewhat tedious, but that solutions for automating these procedures appear to be viable. Magnetic signaling with moving permanent magnets has the potential for sending lowfrequency telemetry signals through soils that are largely impenetrable by other electromagnetic waves.

  14. Electricity

    Indian Academy of Sciences (India)

    which removes the heat produced In the core and the colis. I represents an Isolator which is a kind of. 'switch' used to isolate the station from the grid. Note the huge Insulators (marked I) that are used. The steel structures marked S support the conductors through insulators (courtesy: Kirloskar Electric Company, Bangalore).

  15. Enlarging the underground hydroelectric plant at Villarino, Spain

    Energy Technology Data Exchange (ETDEWEB)

    Oriard, L.L.

    1997-05-01

    Near the village of Villarino de los Aires, in the province of Salamanca, Spain, was an existing underground hydroelectric power plant. A major enlargement was undertaken to increase the electrical generating capacity, under a contract awarded to a joint venture of Dragados y Construcciones, S. A. (Spain), Entrecanales y Tavora, S. A. (Spain), and S.A. Conrad Zschokke (Switzerland). The enlargement required the excavation of a large and complex underground system of tunnels, shafts and chambers adjacent to existing facilities and interconnected with these facilities. The existing machine hall and transformer chamber were both extended, requiring the blasting of the existing end walls. The drilling, blasting and excavating of the underground system had to be done without damage to existing underground chambers and tunnels, or any of the existing structures, equipment or instrumentation facilities, often within just a few feet of the blasting. This required careful control of vibrations, airblast overpressures and dust. Because the only available non-electric detonating systems were found to be unreliable and unsafe, electric systems would be preferred if they could be used in a safe manner at this site. High electrical potentials existed at the site, and the facilities could not be shut down. Electrical fields were studied carefully, both in the underground environment and above the ground surface. Based on these results, it was concluded that electric detonators could be used if special blasting procedures were developed and followed. In accord with contracting practices of this Spanish agency, the contract was not awarded to the lowest bidder, but to the bidder who demonstrated the best understanding of the project and who presented the best technical proposal for conducting the work to a conclusion that would be satisfactory to the owner. The development of the technical proposal was a two-month effort for a technical group and support staff, prepared in Madrid.

  16. Underground layout tradeoff study

    International Nuclear Information System (INIS)

    1988-01-01

    This report presents the results of a technical and economic comparative study of four alternative underground layouts for a nuclear waste geologic repository in salt. The four alternatives considered in this study are (1) separate areas for spent fuel (SF) and commercial high-level waste (CHLW); (2) panel alternation, in which SF and CHLW are emplaced in adjacent panels of rooms; (3) room alternation, in which SF and CHLW are emplaced in adjacent rooms within each panel; and (4) intimate mixture, in which SF and CHLW are emplaced in random order within each storage room. The study concludes that (1) cost is not an important factor; (2) the separate-areas and intimate-mixture alternatives appear, technically, to be more desirable than the other alternatives; and (3) the selection between the separate-areas and intimate mixture alternatives depends upon future resolution of site-specific and reprocessing questions. 5 refs., 6 figs., 12 tabs

  17. Underground space planning in Helsinki

    Directory of Open Access Journals (Sweden)

    Ilkka Vähäaho

    2014-10-01

    Full Text Available This paper gives insight into the use of underground space in Helsinki, Finland. The city has an underground master plan (UMP for its whole municipal area, not only for certain parts of the city. Further, the decision-making history of the UMP is described step-by-step. Some examples of underground space use in other cities are also given. The focus of this paper is on the sustainability issues related to urban underground space use, including its contribution to an environmentally sustainable and aesthetically acceptable landscape, anticipated structural longevity and maintaining the opportunity for urban development by future generations. Underground planning enhances overall safety and economy efficiency. The need for underground space use in city areas has grown rapidly since the 21st century; at the same time, the necessity to control construction work has also increased. The UMP of Helsinki reserves designated space for public and private utilities in various underground areas of bedrock over the long term. The plan also provides the framework for managing and controlling the city's underground construction work and allows suitable locations to be allocated for underground facilities. Tampere, the third most populated city in Finland and the biggest inland city in the Nordic countries, is also a good example of a city that is taking steps to utilise underground resources. Oulu, the capital city of northern Finland, has also started to ‘go underground’. An example of the possibility to combine two cities by an 80-km subsea tunnel is also discussed. A new fixed link would generate huge potential for the capital areas of Finland and Estonia to become a real Helsinki-Tallinn twin city.

  18. Accurately Localize and Recognize Instruments with Substation Inspection Robot in Complex Environments

    Directory of Open Access Journals (Sweden)

    Hui Song

    2014-07-01

    Full Text Available This paper designs and develops an automatic detection system in the substation environment where complex and multi-inspecting objects exist. The inspection robot is able to fix and identify the objects quickly using a visual servo control system. This paper focuses on the analysis of fast lockup and recognition method of the substation instruments based on an improved Adaboost algorithm. The robot adjusts its position to the best view point and best resolution for the instrument in real-time. The dial and pointer of the instruments are detected with an improved Hough algorithm, and the angle of the pointer is converted to the corresponding readings. The experimental results indicate that the inspection robot can fix and identify the substation instruments quickly, and has a wide range of practical applications.

  19. System of automation of substations and distribution networks; Sistema de automacao de subestacoes e redes de distribuicao de energia

    Energy Technology Data Exchange (ETDEWEB)

    Frisch, Arlenio Carneiro; Krauss, Carlos Cesar; Santos, Christina Courtouke dos; Marquez, Diogenes da Cunha; Parolin, Emerson Luis; Pinto, Jose Molinari; Reggiane, Rodrigo [Companhia Paranaense de Energia (COPEL), Curitiba, PR (Brazil)

    2000-07-01

    This paper describes the Director Plan of Automation defining that all operation of substations would be conducted based on the control and digital supervision systems. Functions were analysed that cause more impact on the operation, energy quality and system reliability, being defined that those operations would be automated and implanted locally in the substations and supervised and controlled at distance by the operation centers.

  20. Transient electromagnetic simulations of substation earth grid for improving lightning withstand performance of a large power transformer

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Einarsdottir, Kristin E.; Andresson, Einar

    This paper demonstrates the results from detailed studies of the physical layout of a substation earthing grid. The particular layout of a 400/150 kV substation is modelled in details in MATLAB by means of a thin-wire approach originally developed by J.H.Richmond in 1974 for NASA. A model...

  1. Study on the system-level test method of digital metering in smart substation

    Science.gov (United States)

    Zhang, Xiang; Yang, Min; Hu, Juan; Li, Fuchao; Luo, Ruixi; Li, Jinsong; Ai, Bing

    2017-03-01

    Nowadays, the test methods of digital metering system in smart substation are used to test and evaluate the performance of a single device, but these methods can only effectively guarantee the accuracy and reliability of the measurement results of a digital metering device in a single run, it does not completely reflect the performance when each device constitutes a complete system. This paper introduced the shortages of the existing test methods. A system-level test method of digital metering in smart substation was proposed, and the feasibility of the method was proved by the actual test.

  2. A New Method of Remote Control Checking for Substation Monitoring System Retrofit

    Science.gov (United States)

    Qiongliang, Chen; Li, Chen; Lei, Zhang; Gang, Chen; Feng, Qi; Yale, Xu

    2017-05-01

    In the process of monitoring system retrofit of 500kV Ouhai substation without power cut, because there is no design of remote control outlet plate on the measuring and control device, the remote control checking work cannot be completed by traditional method. After further study of the new and old monitoring system structure and the Siemens 8FW protocol, this paper presents a new method of remote control checking, and applies it in the field successfully, which improved the reliability and efficiency of the remote control checking work significantly. The retrofit scheme in this paper provides certain reference for the same type substation monitoring system retrofit in future.

  3. Designing an Optimal Lightning Protection Scheme for Substations Using Shielding Wires

    Directory of Open Access Journals (Sweden)

    A. Khodadadi

    2017-06-01

    Full Text Available An optimal lightning protection scheme for a substation using shielding wires is investigated in this paper through computer software analysis. An economic approach is utilized by choosing a reasonable trade-off between protection, the number of shielding wires and the heights of them from the ground. This study is initially applied to a simple two-wire system and then extended to a sample substation. The solution for each problem is executed in MATLAB and 3-D realization is shown.

  4. Lessons Learned "Establishing an Electrically Safe Work Condition" Specifically related to Racking Electrical Breakers

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, Tommy Robert [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Philbert Roland [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Garcia, Samuel Anthony [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-09

    During low voltage electrical equipment maintenance, a bad breaker was identified. The breaker was racked out from the substation cubicle without following the hazardous energy control process identified in the Integrated Work Document (IWD). The IWD required the substation to be in an electrically safe work condition prior to racking the breaker. Per NFPA 70E requirements, electrical equipment shall be put into an electrically safe work condition before an employee performs work on or interacts with equipment in a manner that increases the likelihood of creating an arc flash. Racking in or out a breaker on an energized bus may increase the likelihood of creating an arc flash dependent on equipment conditions. A thorough risk assessment must be performed prior to performing such a task. The risk assessment determines the risk control measures to be put in place prior to performing the work. Electrical Safety Officers (ESO) can assist in performing risk assessments and incorporating risk control measures.

  5. KAERI underground research tunnel (KURT)

    International Nuclear Information System (INIS)

    Cho, Won Jin; Kwon, Sang Ki; Park, Jeong Hwa; Choi, Jong Won

    2007-01-01

    An underground research tunnel is essential to validate the integrity of a high-level waste disposal system, and the safety of geological disposal. In this study, KAERI underground research tunnel (KURT) was constructed in the site of Korea Atomic Energy Research Institute(KAERI). The results of the site investigation and the design of underground tunnel were presented. The procedure for the construction permits and the construction of KURT were described briefly. The in-situ experiments being carried out at KURT were also introduced

  6. Rock massif observation from underground coal gasification point of view

    Directory of Open Access Journals (Sweden)

    T. Sasvári

    2009-04-01

    Full Text Available The Underground coal gasification (UCG of the coal seams is determined by suitable geological structure of the area. The assumption of the qualitative changes of the rock massif can be also enabled by application of geophysical methods (electric resisting methods and geoelectric tomography. This article shows the example of evaluating possibilities of realization of the underground coal gasification in the area of the Upper Nitra Coal Basin in Cíge¾ and Nováky deposits, and recommend the needs of cooperation among geological, geotechnical and geophysical researchers.

  7. Underground Facilities, Technological Challenges

    CERN Document Server

    Spooner, N

    2010-01-01

    This report gives a summary overview of the status of international under- ground facilities, in particular as relevant to long-baseline neutrino physics and neutrino astrophysics. The emphasis is on the technical feasibility aspects of creating the large underground infrastructures that will be needed in the fu- ture to house the necessary detectors of 100 kton to 1000 kton scale. There is great potential in Europe to build such a facility, both from the technical point of view and because Europe has a large concentration of the necessary engi- neering and geophysics expertise. The new LAGUNA collaboration has made rapid progress in determining the feasibility for a European site for such a large detector. It is becoming clear in fact that several locations are technically fea- sible in Europe. Combining this with the possibility of a new neutrino beam from CERN suggests a great opportunity for Europe to become the leading centre of neutrino studies, combining both neutrino astrophysics and neutrino beam stu...

  8. ATLAS solenoid operates underground

    CERN Multimedia

    2006-01-01

    A new phase for the ATLAS collaboration started with the first operation of a completed sub-system: the Central Solenoid. Teams monitoring the cooling and powering of the ATLAS solenoid in the control room. The solenoid was cooled down to 4.5 K from 17 to 23 May. The first current was established the same evening that the solenoid became cold and superconductive. 'This makes the ATLAS Central Solenoid the very first cold and superconducting magnet to be operated in the LHC underground areas!', said Takahiko Kondo, professor at KEK. Though the current was limited to 1 kA, the cool-down and powering of the solenoid was a major milestone for all of the control, cryogenic, power and vacuum systems-a milestone reached by the hard work and many long evenings invested by various teams from ATLAS, all of CERN's departments and several large and small companies. Since the Central Solenoid and the barrel liquid argon (LAr) calorimeter share the same cryostat vacuum vessel, this achievement was only possible in perfe...

  9. An embedded underground navigation system

    CSIR Research Space (South Africa)

    Hlophe, K

    2011-11-01

    Full Text Available Platform pose (localization and orientation) information is a key requirement for autonomous mobile systems. The severe natural conditions and complex terrain of underground mines diminish the capability of most pose estimation systems, especially...

  10. Man-entry grid and power substations in Germany; Begehbare Netz- und Uebergabestationen in Deutschland

    Energy Technology Data Exchange (ETDEWEB)

    Primus, Illo-Frank

    2010-11-15

    Since the first publication of an electrotechnical standard for factory-assembled stations in 1997, grid and power substations in Germany as a rule are not constructed on site - with some exceptions, e.g. large-scale switching stations - but as prefabricated, factory-assembled concrete structures. There are two types of stations depending on the producer.

  11. An Auto Tuning Substation Peak Shaving Controller for Congestion Management Using Flexible Demand

    DEFF Research Database (Denmark)

    Sossan, Fabrizio; Marinelli, Mattia

    2013-01-01

    A closed loop substation peak shaving/congestion management controller for radial distribution networks is presented. The controller it uses an individual control signal in order to shift the consumption of a population of demand side resources, DSRs. The controller auto tunes its parameters on...

  12. Modeling reliability of power systems substations by using stochastic automata networks

    International Nuclear Information System (INIS)

    Šnipas, Mindaugas; Radziukynas, Virginijus; Valakevičius, Eimutis

    2017-01-01

    In this paper, stochastic automata networks (SANs) formalism to model reliability of power systems substations is applied. The proposed strategy allows reducing the size of state space of Markov chain model and simplifying system specification. Two case studies of standard configurations of substations are considered in detail. SAN models with different assumptions were created. SAN approach is compared with exact reliability calculation by using a minimal path set method. Modeling results showed that total independence of automata can be assumed for relatively small power systems substations with reliable equipment. In this case, the implementation of Markov chain model by a using SAN method is a relatively easy task. - Highlights: • We present the methodology to apply stochastic automata network formalism to create Markov chain models of power systems. • The stochastic automata network approach is combined with minimal path sets and structural functions. • Two models of substation configurations with different model assumptions are presented to illustrate the proposed methodology. • Modeling results of system with independent automata and functional transition rates are similar. • The conditions when total independence of automata can be assumed are addressed.

  13. THE ANALYSIS OF STEADY VOLTAGE ON THE ACCESSION OF DC TRACTION SUBSTATIONS

    Directory of Open Access Journals (Sweden)

    V. H. Sychenko

    2009-09-01

    Full Text Available Research results of voltage modes at traction substation buses in primary, regional and traction network are presented in the article. Numeric characteristics of probability density distributions are obtained. Autocorrelation functions of positive and negative sequence voltages are analyzed.

  14. Coordinated Voltage Control Scheme for SEIG-Based Wind Park Utilizing Substation STATCOM and ULTC Transformer

    DEFF Research Database (Denmark)

    S. El Moursi, Mohamed; Bak-Jensen, Birgitte; Abdel-Rahman, Mansour Hassan

    2011-01-01

    and optimal tracking secondary voltage control for wind parks based on self-excited induction generators which comprise STATCOM and under-load tap changer (ULTC) substation transformers. The voltage controllers for the STATCOM and ULTC transformer are coordinated and ensure the voltage support. In steady...

  15. Proximity detection system underground

    Energy Technology Data Exchange (ETDEWEB)

    Denis Kent [Mine Site Technologies (Australia)

    2008-04-15

    Mine Site Technologies (MST) with the support ACARP and Xstrata Coal NSW, as well as assistance from Centennial Coal, has developed a Proximity Detection System to proof of concept stage as per plan. The basic aim of the project was to develop a system to reduce the risk of the people coming into contact with vehicles in an uncontrolled manner (i.e. being 'run over'). The potential to extend the developed technology into other areas, such as controls for vehicle-vehicle collisions and restricting access of vehicle or people into certain zones (e.g. non FLP vehicles into Hazardous Zones/ERZ) was also assessed. The project leveraged off MST's existing Intellectual Property and experience gained with our ImPact TRACKER tagging technology, allowing the development to be fast tracked. The basic concept developed uses active RFID Tags worn by miners underground to be detected by vehicle mounted Readers. These Readers in turn provide outputs that can be used to alert a driver (e.g. by light and/or audible alarm) that a person (Tag) approaching within their vicinity. The prototype/test kit developed proved the concept and technology, the four main components being: Active RFID Tags to send out signals for detection by vehicle mounted receivers; Receiver electronics to detect RFID Tags approaching within the vicinity of the unit to create a long range detection system (60 m to 120 m); A transmitting/exciter device to enable inner detection zone (within 5 m to 20 m); and A software/hardware device to process & log incoming Tags reads and create certain outputs. Tests undertaken in the laboratory and at a number of mine sites, confirmed the technology path taken could form the basis of a reliable Proximity Detection/Alert System.

  16. Analysis, simulation and control of electromagnetic transients in gas insulated substations in SF6 by means of grounding grid; Analisis, simulacion y control de transitorios electromagneticos en subestaciones aisladas en SF6 por medio de redes de tierra

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez Martinez, Gaston

    2007-12-15

    The use of SF6 substations is actually an extensive practice in industrial countries. Some of they replace conventional air substations and the others are new designs in the range of 34.5 kV to 1000 kV. During the switching events in a GIS substation, very fast transients overvoltage may appear and originate faults, malfunctions in the electronic and control equipment, besides the risk by electrical discharge in the personnel who are working in the substation. These overvoltage are produced by the collapse of the electric field on GIS terminals during switching events originating Very Fast Transient Overvoltage (VFTO) and the increase of the Transient Enclosure Voltage (TEV). This investigation is focused on diminishing the magnitude of the VFTO and TEV by designing and redesigning grounding grids for gas insulated substations in SF6. The objective of this work is to design a grounding grid for an air substation and redesign it for a GIS substation. The computer simulation uses a detailed model of the substation in SF6 interconnected with an aerial grounding grid and by adding methodologically grounding rods, the VFTO and TEV within the GIS are reduced. The results of the computer simulation show that the designed grounding grid allows considerably diminishing the magnitude of the VFTO; nevertheless this design doesn't appropriately attenuate the TEV magnitude. [Spanish] Hoy en dia, el uso de subestaciones GIS se ha generalizado. Algunas reemplazan a las subestaciones aereas y otras son de nueva creacion y se instalan en tensiones de 34.5kV hasta 1000 kV. Durante las operaciones de maniobra de la subestacion GIS, se presentan sobretensiones transitorias ultra rapidas que pueden dar origen a diversas fallas, a un malfuncionamiento del equipo electronico y de control asi como el riesgo por descarga electrica al personal que labora en la subestacion. Estas sobretensiones se producen debido al colapso del campo electrico en terminales del interruptor ante

  17. Overview of electrical energy in may 2003

    International Nuclear Information System (INIS)

    2003-01-01

    This document aims to give information on the exploitation of the transmission public network and the french electric power industry during may 2003: the internal electric power consumption in France (national consumption is the total of all the electrical energy supplied for consumption in France (including Corsica, but not the French Overseas Departments), thermal and hydro generation + imports - exports - pumping, and which have been consumed in the transmission and distribution networks, by the end-users, as well as by losses) - May 2003 gross consumption is 1.4% lower compared to May 2002. This is due to a 1.3 deg. C rise this year in May average temperature. However, the monthly consumption is 0.9% higher than May 2002 consumption if climatic effects are put aside. The growth rate of the corrected consumption over the last 12 months shows a rise of 0.2% from last month, whereas the growth rate of gross consumption over the last 12 months shows a decrease of 0.2% compared to April 2002; the energy accounting from the transmission point of view (The balance recorded by RTE takes into account only the energy physical flows conveyed on the RTE network) - on May 2003, consumption has fallen compared to May 2002, as did exports (-0.9 TWh). Consequently the global volume of injections shows a loss of 1.2 TWh. Compared to May 2002, thermal generation and hydroelectric generation have respectively lost 1.1 TWh and 0.3 TWh. Imports are roughly 0.2 TWh up; the consumption and the physical exchanges (these values reflect all the flows on the RTE network, as well as the generation auto-consumed by the industrial consumers connected to this network); the electric power market: the market players, contractual exchanges recorded by RTE contracts for access to international connections, contractual exchanges by border; and the evolution of the transmission network: on May 2003 the 4.3 km-long 225 kV Bouscat-Bruges underground link has come into service on the RTE system

  18. An expansion plan for the 60 Hz power distribution system at KSC: LC-39 substations load allocation plan

    Science.gov (United States)

    Kalu, Alex

    1990-01-01

    The increasing load density in the LC-39 area of Kennedy Space Center (KSC) can be met by either modifying the existing substation and increasing its capacity or by planning an additional new substation. Evidence that the later approach is more economical, enhances the system reliability, and would produce more satisfactory performance indices is provided. Network theory is the basis for the optimal location determination of the proposed substation. A load reallocation plan which minimizes investment cost and power losses and meets other desirable system features is drafted. The report should be useful to the system designer and can be a useful guideline for future facility planners.

  19. Reflection Phenomena in Underground Pumped Storage Reservoirs

    Directory of Open Access Journals (Sweden)

    Elena Pummer

    2018-04-01

    Full Text Available Energy storage through hydropower leads to free surface water waves in the connected reservoirs. The reason for this is the movement of water between reservoirs at different elevations, which is necessary for electrical energy storage. Currently, the expansion of renewable energies requires the development of fast and flexible energy storage systems, of which classical pumped storage plants are the only technically proven and cost-effective technology and are the most used. Instead of classical pumped storage plants, where reservoirs are located on the surface, underground pumped storage plants with subsurface reservoirs could be an alternative. They are independent of topography and have a low surface area requirement. This can be a great advantage for energy storage expansion in case of environmental issues, residents’ concerns and an unusable terrain surface. However, the reservoirs of underground pumped storage plants differ in design from classical ones for stability and space reasons. The hydraulic design is essential to ensure their satisfactory hydraulic performance. The paper presents a hybrid model study, which is defined here as a combination of physical and numerical modelling to use the advantages and to compensate for the disadvantages of the respective methods. It shows the analysis of waves in ventilated underground reservoir systems with a great length to height ratio, considering new operational aspects from energy supply systems with a great percentage of renewable energies. The multifaceted and narrow design of the reservoirs leads to complex free surface flows; for example, undular and breaking bores arise. The results show excessive wave heights through wave reflections, caused by the impermeable reservoir boundaries. Hence, their knowledge is essential for a successful operational and constructive design of the reservoirs.

  20. Underground disposal of radioactive wastes

    International Nuclear Information System (INIS)

    1981-01-01

    This report is an overview document for the series of IAEA reports dealing with underground waste disposal to be prepared in the next few years. It provides an introduction to the general considerations involved in implementing underground disposal of radioactive wastes. It suggests factors to be taken into account for developing and assessing waste disposal concepts, including the conditioned waste form, the geological containment and possible additional engineered barriers. These guidelines are general so as to cover a broad range of conditions. They are generally applicable to all types of underground disposal, but the emphasis is on disposal in deep geological formations. Some information presented here may require slight modifications when applied to shallow ground disposal or other types of underground disposal. Modifications may also be needed to reflect local conditions. In some specific cases it may be that not all the considerations dealt with in this book are necessary; on the other hand, while most major considerations are believed to be included, they are not meant to be all-inclusive. The book primarily concerns only underground disposal of the wastes from nuclear fuel cycle operations and those which arise from the use of isotopes for medical and research activities

  1. 30 CFR 77.500 - Electric power circuits and electric equipment; deenergization.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric power circuits and electric equipment... OF UNDERGROUND COAL MINES Electrical Equipment-General § 77.500 Electric power circuits and electric equipment; deenergization. Power circuits and electric equipment shall be deenergized before work is done on...

  2. Job Grading Standard for Electric Power Controller WG-5407.

    Science.gov (United States)

    Civil Service Commission, Washington, DC. Bureau of Policies and Standards.

    The standard is used to grade nonsupervisory jobs involved in controlling the generation or distribution of electric power. The jobs are located at power generating plants, power distribution centers, and substations. The work requires ability to anticipate load changes due to work schedules, weather, and other variables, in order to engage or cut…

  3. Performance of bulk oil circuit breaker (BOCB) influenced by its parameters (Case study at the substation of Bogor Baru)

    Science.gov (United States)

    Goeritno, Arief; Rasiman, Syofyan

    2017-06-01

    Performance examination of the bulk oil circuit breaker that is influenced by its parameters at the Substation of Bogor Baru (the State Electricity Company = PLN) has been done. It is found that (1) dielectric strength of oil still qualifies as an insulating and cooling medium, because the average value of the measurement result is still above the minimum value allowed, where the minimum limit of 80 kV/2.5 cm or 32 kV/cm; (2) the simultaneity of the CB's contacts is still eligible, so that the BOCB can still be operated, because the difference of time between the highest and lowest values when the BOCB's contacts are opened/closed are less than (Δt<) 10 milliseconds (if meeting the PLN standards as recommended by Alsthom); and (3) the parameter of resistance according to the standards, where (i) the resistance of insulation has a value far above the allowed threshold, while the minimum standards are above 2,000 Mn (if meeting the ANSI standards) or on the value of 2,000 MΩ (if meeting PLN standards), (ii) the resistance of contacts has a value far above the allowed threshold, while the minimum standards are below 350 µΩ (if meeting ANSI standards) or on the value of 200 µΩ (if meeting PLN standards). The resistance of grounding is equal to the maximum limit specified, while the maximum standard is on the value of 0.5 Ω (if meeting PLN standard).

  4. Improving the performance of subtransmission through substation reinforcement; Melhoria do desempenho de sistemas de subtransmissao atraves de reforcos em substacoes

    Energy Technology Data Exchange (ETDEWEB)

    Paiva Mendes, Dilcemar de [Ceara Univ., Fortaleza, CE (Brazil); Melo, Albert Cordeiro Geber de [Centro de Pesquisas de Energia Eletrica (CEPEL), Rio de Janeiro, RJ (Brazil); Pereira, Jose Luiz Rezende [Juiz de Fora Univ., MG (Brazil)

    1994-12-31

    This work presents an approach to the global reliability improve of power subtransmission systems through of reinforcements in critical components of the power substations. (author) 13 refs., 3 figs., 3 tabs.

  5. Underground Nuclear Astrophysics in China

    Science.gov (United States)

    Liu, Weiping

    2016-10-01

    Underground Nuclear Astrophysics in China (JUNA) will take the advantage of the ultra-low background in Jinping underground lab. High current accelerator with an ECR source and detectors will be set up. We plan to study directly a number of nuclear reactions important to hydrostatic stellar evolution at their relevant stellar energies, such as 25Mg(p,γ)26Al, 19F(p,α)16O, 13C(α,n)16O and 12C(α,γ)16O.

  6. Electric and magnetic field measurements in a high voltage center.

    Science.gov (United States)

    Safigianni, Anastasia S; Spyridopoulos, Anastasios I; Kanas, Vasilis L

    2012-01-01

    This paper investigates the electric and magnetic fields inside a large high voltage center constituted both of 400/150 and 150/20 kV substation areas. Results of previous field measurements and calculations in substations, made by the authors of this paper or other researchers, are presented first. The basic data distinguishing the examined center from previously examined substations follow. The main results of the field measurements in the areas of the above-mentioned center are presented in relevant diagrams. General conclusions arising from the comparison of the measured field values with relevant reference levels in force for safe public and occupational exposure as well as with the results of previous research are finally given.

  7. Laplace Synthesis Validation through Measurements on Underground Transmission Cables

    Directory of Open Access Journals (Sweden)

    Uribe-Campos Felipe Alejandro

    2014-10-01

    Full Text Available Underground cable electrical parameters ZY as well as their modal propagation characteristics are highly frequency dependent which in certain cases turns its analysis difficult. To perform electromagnetic transient studies of cables the calculation of electrical parameters is essential to obtain the waves propagation solution through the multiconductor system. At the same time this requires to solve the inverse Laplace transform on a numerical form. Although the analytic Laplace transform has an indisputable accuracy, the application of its numerical version up-to-date has not been completely accepted. A complete methodology is developed in this work to guide analyst engineers or graduate students in the calculation of electromagnetic transients of underground cable systems. Finally, to help the validation of the numerical inverse Laplace transform a scaled prototype experiment is performed in the laboratory in which a transient step-response at the remote end of an energized conductor is measured.

  8. 30 CFR 75.1703 - Portable electric lamps.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...

  9. The future of substation automation (protection, control, system)

    Energy Technology Data Exchange (ETDEWEB)

    Tholomier, D. [Areva T and D Automation Canada Inc., Monteal, PQ (Canada); Hossenlopp, L. [Areva T and D Automation Inc., Paris (France); Apostolov, A. [Omicron Electronics, Houston, TX (United States)

    2008-07-01

    This paper described a high-level plan for implementing wide-area control in an energy management system (EMS) designed to improve power system grid security and protect the electrical interconnection from a widespread collapse. The appropriate action in some cases would be islanding and blacking out a portion of the grid in order to prevent widespread collapse. The use of new automation solutions can address costly shortcomings in capacity, reliability, power quality and security. International organizations such as the Institute of Electrical and Electronics Engineers (IEEE), International Electrotechnical Commission (IEC) and the Conseil International des Grands Reseaux Electriques (CIGRE) launched several working groups to analyze the context of major blackouts and develop concepts for the use of new technologies and coordinated investment strategies to modernize the power system infrastructure. The main benefits of such smart grid systems would be: no wide-area blackouts, far fewer localized disruptions, and faster recovery when disruptions do occur; greater security from self-healing technologies and better real-time monitoring and response; high-quality power needed for sensitive electronics and computer applications; and new options for consumers to manage their electricity use and costs. The authors noted that in order to gain the full advantages of the new IEC 61850 standard there is a need to change project execution processes and prioritize various changes. This paper demonstrated the importance of system design and outlined some system engineering and interoperability tests aspects. 17 figs.

  10. Electric utility report '80

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    A collection of brief atricles describes the trends and developments in Canada's electric utilities for the 1980's. Generating stations planned or under construction are listed. The trends in technology discused at a recent Canadian Electrical Association meeting are summarized in such areas as turbine stability control, power line vibration control, system reliability, substations and transformer specifications. Developments in nuclear generation are discussed and compared on the world scale where Japan, for example, has the world's largest nuclear program. Progress on fusion is discussed. In Canada the electric utilities are receiving the support of the comprehensive nuclear R and D program of Atomic Energy of Canada Ltd. New innovations in utility technology such as street lighting contactors, superconductive fault limiters and demand profile analyzers are discussed. (T.I.)

  11. Design requirements document for the phase 1 privatization electrical power system

    International Nuclear Information System (INIS)

    Singh, G.

    1997-01-01

    The electrical system for the Phase 1 privatization facilities will support the TWRS mission by providing the electrical power to the Phase 1 privatized facilities. This system will receive power from the Department of Energy-Richland Operations (RL) A4-8 230 kV transmission system powered from Bonneville Power Administration (BPA) Ashe and Midway 230 kV Substations. The existing RL 230 kV transmission line will be modified and looped 1021 into the new 230 kV substation bus. The new substation will be located in the vicinity of the privatized facilities, approximately 3.2 km (2 mi) south of the existing RL A4-8 230 kV transmission line. The substation will be capable of providing up to 40 MW of electrical power to support the Phase 1 privatization facilities and has space for accommodating future expansions. The substation will require at least two 230-13.8 kV transformers, 13.8 kV split bus switchgear, switchgear building, grounding transformers, instrument transformers, control and monitoring equipment, associated protection and isolation devices, lightning protection, yard lighting, cable and raceways, and infrastructure needed to provide desired availability and reliability. The power from the 13.8 kV switchgear located in the switchgear building will be delivered at the privatization facilities site boundaries. The 13.8 kV distribution system inside the privatization facilities site boundaries is the responsibility of the privatization contract

  12. Design requirements document for the phase 1 privatization electrical power system

    Energy Technology Data Exchange (ETDEWEB)

    Singh, G.

    1997-10-31

    The electrical system for the Phase 1 privatization facilities will support the TWRS mission by providing the electrical power to the Phase 1 privatized facilities. This system will receive power from the Department of Energy-Richland Operations (RL) A4-8 230 kV transmission system powered from Bonneville Power Administration (BPA) Ashe and Midway 230 kV Substations. The existing RL 230 kV transmission line will be modified and looped 1021 into the new 230 kV substation bus. The new substation will be located in the vicinity of the privatized facilities, approximately 3.2 km (2 mi) south of the existing RL A4-8 230 kV transmission line. The substation will be capable of providing up to 40 MW of electrical power to support the Phase 1 privatization facilities and has space for accommodating future expansions. The substation will require at least two 230-13.8 kV transformers, 13.8 kV split bus switchgear, switchgear building, grounding transformers, instrument transformers, control and monitoring equipment, associated protection and isolation devices, lightning protection, yard lighting, cable and raceways, and infrastructure needed to provide desired availability and reliability. The power from the 13.8 kV switchgear located in the switchgear building will be delivered at the privatization facilities site boundaries. The 13.8 kV distribution system inside the privatization facilities site boundaries is the responsibility of the privatization contract.

  13. Earthquake damage to underground facilities

    International Nuclear Information System (INIS)

    Pratt, H.R.; Stephenson, D.E.; Zandt, G.; Bouchon, M.; Hustrulid, W.A.

    1980-01-01

    In order to assess the seismic risk for an underground facility, a data base was established and analyzed to evaluate the potential for seismic disturbance. Substantial damage to underground facilities is usually the result of displacements primarily along pre-existing faults and fractures, or at the surface entrance to these facilities. Evidence of this comes from both earthquakes and large explosions. Therefore, the displacement due to earthquakes as a function of depth is important in the evaluation of the hazard to underground facilities. To evaluate potential displacements due to seismic effects of block motions along pre-existing or induced fractures, the displacement fields surrounding two types of faults were investigated. Analytical models were used to determine relative displacements of shafts and near-surface displacement of large rock masses. Numerical methods were used to determine the displacement fields associated with pure strike-slip and vertical normal faults. Results are presented as displacements for various fault lengths as a function of depth and distance. This provides input to determine potential displacements in terms of depth and distance for underground facilities, important for assessing potential sites and design parameters

  14. Uranium extraction from underground deposits

    International Nuclear Information System (INIS)

    Wolfe, C.R.

    1982-01-01

    Uranium is extracted from underground deposits by passing an aqueous oxidizing solution of carbon dioxide over the ore in the presence of calcium ions. Complex uranium carbonate or bicarbonate ions are formed which enter the solution. The solution is forced to the surface and the uranium removed from it

  15. A new test procedure to evaluate the performance of substations for collective heating systems

    Science.gov (United States)

    Baetens, Robin; Verhaert, Ivan

    2017-11-01

    The overall heat demand of a single dwelling, existing out of space heating and domestic hot water production, decreases due to higher insulation rates. Because of this, investing in efficient and renewable heat generation becomes less interesting. Therefore, to incorporate renewables or residual heat on a larger scale, district heating or collective heating systems grow in importance. Within this set-up, the substation is responsible for the interaction between local demand for comfort and overall energy performance of the collective heating system. Many different configurations of substations exist, which influence both local comfort and central system performance. Next to that, also hybrids exist with additional local energy input. To evaluate performance of such substations, a new experimental-based test procedure is developed in order to evaluate these different aspects, characterized by the two roles a substation has, namely as heat generator and as heat consumer. The advantage of this approach is that an objective comparison between individual and central systems regarding performance on delivering local comfort can be executed experimentally. The lab set-up consists out of three different subsystems, namely the central system, the domestic hot water consumption and the local space heating. The central system can work with different temperature regimes and control strategies, as these aspects have proven to have the largest influence on actual performance. The domestic hot water system is able to generate similar tap profiles according to eco-design regulation for domestic hot water generation. The space heating system is able to demand a modular heat load.

  16. A new test procedure to evaluate the performance of substations for collective heating systems

    Directory of Open Access Journals (Sweden)

    Baetens Robin

    2017-01-01

    Full Text Available The overall heat demand of a single dwelling, existing out of space heating and domestic hot water production, decreases due to higher insulation rates. Because of this, investing in efficient and renewable heat generation becomes less interesting. Therefore, to incorporate renewables or residual heat on a larger scale, district heating or collective heating systems grow in importance. Within this set-up, the substation is responsible for the interaction between local demand for comfort and overall energy performance of the collective heating system. Many different configurations of substations exist, which influence both local comfort and central system performance. Next to that, also hybrids exist with additional local energy input. To evaluate performance of such substations, a new experimental-based test procedure is developed in order to evaluate these different aspects, characterized by the two roles a substation has, namely as heat generator and as heat consumer. The advantage of this approach is that an objective comparison between individual and central systems regarding performance on delivering local comfort can be executed experimentally. The lab set-up consists out of three different subsystems, namely the central system, the domestic hot water consumption and the local space heating. The central system can work with different temperature regimes and control strategies, as these aspects have proven to have the largest influence on actual performance. The domestic hot water system is able to generate similar tap profiles according to eco-design regulation for domestic hot water generation. The space heating system is able to demand a modular heat load.

  17. A Real-Time Digital Solver for Smart Substation Based on Orders

    Directory of Open Access Journals (Sweden)

    Bingda Zhang

    2017-11-01

    Full Text Available In order to expand the simulation scale of smart substation, a simulation model of the inlet-outlet line unit, as described by the 0/108 S conductance for multivalued coefficients pre-storage is presented in this paper. As a part of orders decomposition, the address conversion circuit for multivalued coefficients can reduce the computational burden of processing elements. For the convenience of the generalization of the real-time digital solver based on FPGA (FRTDS, FPGA: Field–Programmable Gate Array, the address conversion circuit for multivalued coefficients is matched with the guide word, the formation module of sampled value (SV packet, and the resolution module of generic object oriented substation event (GOOSE packet are associated with the application identification (APPID in the Ethernet frame. The address conversion circuit for multivalued coefficients, the formation module of SV packet, and the resolution module of GOOSE packet are reconstructed via the orders. A hardware-in-the-loop real-time simulation platform for smart substation is built based on the novel FRTDS. A case is given to demonstrate the simulation calculating capability and the hardware-in-the-loop ability of the novel FRTDS.

  18. Ingledow 500 kV substation : using mixed technology switchgear solutions for replacement

    Energy Technology Data Exchange (ETDEWEB)

    Wallner, C.; Glaubitz, P. [Siemens AG, Munich (Germany); Messinger, T. [British Columbia Transmission Corp., Vancouver, BC (Canada)

    2008-07-01

    The reliability of the 500 kV equipment at the Ingledow substation operated by BC Hydro Transmission System is of critical importance due to the energy interchange with the Bonneville Power Authority in the United States and the major role of the substation in serving the energy needs of British Columbia's densely populated Lower Mainland. Presently, the 500 kV switchyard includes 10 airblast circuit breakers and the associated current transformers which are all approaching their end of service-life. In response to environmental and safety concerns, the British Columbia Transmission Corporation adopted a policy whereby new oil-filled transformers are no longer acceptable, and the replacement of existing oil-filled transformers must be oil-free. The result is that the current transformers must be either bushing-type or sulphur-hexafluoride (SF6) type. The replacement strategies for the substation equipment consider economical, environmental and seismic issues. They have just as strong an influence on the decision process as the technical, operational and reliability aspects for the particular case or switchgear replacement in the transmission system. The Ingledow case demonstrates the advantages of using mixed technology switchgear, with its compact design flowing from gas insulated switchgear (GIS) for replacement of equipment in an outdoor switchyard. The advantages of the MTS in this case offer the possibility of future reconfiguration to improve the system reliability within the existing switchyard space. 3 refs., 5 figs.

  19. Traction Converting Substation from Viewpoint of Feeding Interlocking Plant at Czech Railwayes

    Directory of Open Access Journals (Sweden)

    Radovan Dolecek

    2004-01-01

    Full Text Available This paper presents analyses current and voltage harmonic in traction converting substation 3 kV. It researches their rise and influence to three-phase cable line 6 kV, 50 Hz that is used for feeding interlocking plant. Processing of this task is arisen from requirement practice for line Pěčky - Poříčany - Rostoklaty where happened to adverse ratio in particular transmission line of feeding system. It is meant especially about backward influence traction substation rectifier Pečky to three - phase cable line 6 kV, 50 Hz. At the determinate lenght of the cable line, when resonace frequency of circuit transformer 22 kV/6 kV and the cable line 6 kV, 50 Hz is approached frequency 550 Hz and 650 Hz (i.e. 11 and 13 harmonic are happened to socalled "annulations input reactance of this circuit". That is caused by the leakage of current resonace frequency from traction converting substation to cable line. That proceduces additional losses and deformation waveform of voltage too. This deformation can be reflected on how interlocking plant is working. 

  20. New model of inverting substation for DC traction with regenerative braking system

    Science.gov (United States)

    Omar, Abdul Malek Saidina; Samat, Ahmad Asri Abd; Isa, Siti Sarah Mat; Shamsuddin, Sarah Addyani; Jamaludin, Nur Fadhilah; Khyasudeen, Muhammad Farris

    2017-08-01

    This paper presents a power electronic devices application focus on modeling, analysis, and control of switching power converter in the inverting DC substation with regenerative braking system which is used to recycle the surplus regenerative power by feed it back to the main AC grid. The main objective of this research is to improve the switching power electronic converter of the railway inverting substation and optimize the maximum kinetic energy recovery together with minimum power losses from the railway braking system. Assess performance including efficiency and robustness will be evaluated in order to get the best solution for the design configuration. Research methodology included mathematical calculation, simulation, and detail analysis on modeling of switching power converter on inverting substation. The design stage separates to four main areas include rectification mode, regenerative mode, control inverter mode and filtering mode. The simulation result has shown that the regenerative inverter has a capability to accept a maximum recovery power on the regeneration mode. Total energy recovery has increase and power losses have decreases because inverter abilities to transfer the surplus energy back to the main AC supply. An Inverter controller with PWM Generator and PI Voltage Regulator has been designed to control voltage magnitude and frequency of the DC traction system.

  1. Study on Earthquake Response of High Voltage Electrical Equipment Coupling System with Flexible Busbar

    Science.gov (United States)

    Liu, Chuncheng; Qu, Da; Wang, Chongyang; Lv, Chunlei; Li, Guoqiang

    2017-12-01

    With the rapid development of technology and society, all walks of life in China are becoming more and more dependent on power systems. When earthquake occurs, the electrical equipment of substation is prone to damage because of its own structural features, top-heavy, and brittleness of main body. At the same time, due to the complex coupling of the soft electrical connection of substation electrical equipment, the negative impact can not be estimated. In this paper, the finite element model of the coupling system of the single unit of high voltage electrical equipment with the connecting soft bus is established and the seismic response is analysed. The results showed that there is a significant difference between the simple analysis for the seismic response of electrical equipment monomer and the analytical results of electrical equipment systems, and the impact on different electrical equipment is different. It lays a foundation for the future development of seismic performance analysis of extra high voltage electrical equipment.

  2. 29 CFR 1926.800 - Underground construction.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Underground Construction, Caissons, Cofferdams and..., floor or walls in any underground work area for more than a 24-hour period; or (ii) The history of the... inches (304.8 mm) ±0.25 inch (6.35 mm) from the roof, face, floor or walls in any underground work area...

  3. Technique on rationalization of using electricity and cases

    International Nuclear Information System (INIS)

    1988-04-01

    This book deals with rationalization of using electric and cases. It is divided into four parts. The first part introduces necessity and of progression rationalization of using electric. The second part describes the technique on rationalization of using electric with management of electric energy. The third part depicts domestic cases of rationalization on using of electric such as substation and motor. The last part also introduces foreign cases of rationalization on using of electric with measure of generator circuit, design of motor, design of lighting and design of other equipment.

  4. Life cycle assessment of overhead and underground primary power distribution.

    Science.gov (United States)

    Bumby, Sarah; Druzhinina, Ekaterina; Feraldi, Rebe; Werthmann, Danae; Geyer, Roland; Sahl, Jack

    2010-07-15

    Electrical power can be distributed in overhead or underground systems, both of which generate a variety of environmental impacts at all stages of their life cycles. While there is considerable literature discussing the trade-offs between both systems in terms of aesthetics, safety, cost, and reliability, environmental assessments are relatively rare and limited to power cable production and end-of-life management. This paper assesses environmental impacts from overhead and underground medium voltage power distribution systems as they are currently built and managed by Southern California Edison (SCE). It uses process-based life cycle assessment (LCA) according to ISO 14044 (2006) and SCE-specific primary data to the extent possible. Potential environmental impacts have been calculated using a wide range of midpoint indicators, and robustness of the results has been investigated through sensitivity analysis of the most uncertain and potentially significant parameters. The studied underground system has higher environmental impacts in all indicators and for all parameter values, mostly due to its higher material intensity. For both systems and all indicators the majority of impact occurs during cable production. Promising strategies for impact reduction are thus cable failure rate reduction for overhead and cable lifetime extension for underground systems.

  5. Deep Learning for Intelligent Substation Device Infrared Fault Image Analysis

    Directory of Open Access Journals (Sweden)

    Lin Ying

    2016-01-01

    Full Text Available As an important kind of data for device status evaluation, the increasing infrared image data in electrical system puts forward a new challenge to traditional manually processing mode. To overcome this problem, this paper proposes a feasible way to automatically process massive infrared fault images. We take advantage of the imaging characteristics of infrared fault images and detect fault regions together with its belonging device part by our proposed algorithm, which first segment images into superpixels, and then adopt the state-of-the-art convolutional and recursive neural network for intelligent object recognition. In the experiment, we compare several unsupervised pre-training methods considering the importance of a pre-train procedure, and discuss the proper parameters for the proposed network. The experimental results show the good performance of our algorithm, and its efficiency for infrared analysis.

  6. Underground Coal Preparation System and Applications

    Science.gov (United States)

    Wei, Cao; DeYong, Shang; BaoNing, Zhang

    2018-03-01

    The underground coal preparation is a cutting-edge technology of the coal industry worldwide. This paper introduced the meaning of implementing the underground coal preparation, and the practical applications of underground mechanical moving screen jig, underground heavy medium shallow slot and underground air jigger. Through analyzing the main separation equipment and the advantages and disadvantages of three primary processes from aspects of process complexity, slime water treatment, raw coal preparation, etc., the difference among technology investment, construction scale, production cost and economic benefit is concluded.

  7. Volume II solicitation package for solicitation no. 522887-5422 {open_quotes}site electrical replacements & substation{close_quotes} subproject: 69 KV substation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1991-05-03

    This solicitation is for the U.S. Department of Energy under Prime Contract No. DE-AC04-88-DP43495 with EG&G Mound Applied Technologies. Ohio Sales or Use taxes are not to be included in the proposal price. Applicable taxes due or owing to the State of Ohio will be paid by the buyer under Direct Payment Permit No. 98-002230. Refer to Form ML-2487, General Provisions, Article 24, {open_quotes}Federal, State & Local Taxes{close_quotes}. Sellers are advised that purchases of building and construction materials for incorporation into a structure or improvement to a real property which is accepted for ownership by the United States or one of its agencies are exempt from Ohio Sales and Use taxes. Unnecessarily elaborate brochures or other presentations beyond those sufficient to present a complete and effective response to this solicitation are not desired and may be construed as an indication of the seller`s lack of cost consciousness. Elaborate art work, expensive paper and binding, and expensive visual and other presentation aids are neither necessary nor wanted.

  8. 30 CFR 75.509 - Electric power circuit and electric equipment; deenergization.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric power circuit and electric equipment... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.509 Electric power circuit and electric equipment; deenergization. [Statutory Provisions] All...

  9. Advanced approach for determination of earthing characteristics of high voltage substations in terms of their optimal protection from lightning strike

    International Nuclear Information System (INIS)

    Talevski, Vladimir

    2012-01-01

    At the beginning of this PhD thesis, retrospective history is given concerning the evolution of the methods for lightning protection. The conventional methods are presented concerning lighting protection, with a comparation with the newest achievement on this field. The process of thundercloud formation is presented. The foundation of the conventional method for lightning protection is given, using data from standard IEC 62305, made according Berger research documents [10], [47], [53].The basic of the 'charge transfer system' is presented, developed by Carpenter, and in addition to this theory is the recently published theory of Rizk and his conditions of not initiating an upward leader for an object that is protected by lightning strike. Also it is high-voltage substation according to [52] and [54]. In this PhD thesis, a method for computation of additional positive charge is established for protection against direct lightning strike by the charge transfer system, which is generated over spherical electrode (ionizator) in order to get 'ultra-corona' mode, condition in which the corona current over the ionizator is not generating an upward leader. The ionizator in this computation is concerned with constant radius of curvature. The influence of the voltage increase in a very small time interval is computed and this influence is concerned in the computation of the additional space charge on the object to be protected, according to Rizk [1]. The model of the electrical thundercloud is concerned with all the electrical charge in it with its corresponding heights above ground. At the end , the condition of having minimal electrostatic field at earth is used to get the result for the additional positive charge. The computation is established by special function in Matlab, which are programmed in order to simulate a large number of values for: the electrical model of the thundercloud (positive and negative charges in thundercloud and their respective height above ground

  10. Evaluation of energy system analysis techniques for identifying underground facilities

    Energy Technology Data Exchange (ETDEWEB)

    VanKuiken, J.C.; Kavicky, J.A.; Portante, E.C. [and others

    1996-03-01

    This report describes the results of a study to determine the feasibility and potential usefulness of applying energy system analysis techniques to help detect and characterize underground facilities that could be used for clandestine activities. Four off-the-shelf energy system modeling tools were considered: (1) ENPEP (Energy and Power Evaluation Program) - a total energy system supply/demand model, (2) ICARUS (Investigation of Costs and Reliability in Utility Systems) - an electric utility system dispatching (or production cost and reliability) model, (3) SMN (Spot Market Network) - an aggregate electric power transmission network model, and (4) PECO/LF (Philadelphia Electric Company/Load Flow) - a detailed electricity load flow model. For the purposes of most of this work, underground facilities were assumed to consume about 500 kW to 3 MW of electricity. For some of the work, facilities as large as 10-20 MW were considered. The analysis of each model was conducted in three stages: data evaluation, base-case analysis, and comparative case analysis. For ENPEP and ICARUS, open source data from Pakistan were used for the evaluations. For SMN and PECO/LF, the country data were not readily available, so data for the state of Arizona were used to test the general concept.

  11. Underground spaces/cybernetic spaces

    Directory of Open Access Journals (Sweden)

    Tomaž Novljan

    2000-01-01

    Full Text Available A modern city space is a space where in the vertical and horizontal direction dynamic, non-linear processes exist, similar as in nature. Alongside the “common” city surface, cities have underground spaces as well that are increasingly affecting the functioning of the former. It is the space of material and cybernetic communication/transport. The psychophysical specifics of using underground places have an important role in their conceptualisation. The most evident facts being their limited volume and often limited connections to the surface and increased level of potential dangers of all kinds. An efficient mode for alleviating the effects of these specific features are artistic interventions, such as: shape, colour, lighting, all applications of the basic principles of fractal theory.

  12. Treatment of an underground formation

    Energy Technology Data Exchange (ETDEWEB)

    Hudson, P.E.; Braden, W.B. Jr.

    1974-03-12

    A method is described for treating underground formations, especially those containing clays or clay-like materials which are sensitive to fresh water. The treatment densensitizes the clays so they will not swell or disperse on contact with fresh water. The procedure consists of contacting the clay-containing formation with solutions which accomplish the electroless deposition of metal on the clay particles. Optionally, the formation can be resin coated prior to electroless plating. (9 claims)

  13. The Underground Economy in Romania

    Directory of Open Access Journals (Sweden)

    Cleopatra Sendroiu

    2006-07-01

    Full Text Available Underground economic activities exist in most countries around the world, and they usually have the same causes: inadequate tax systems, excessive state interference in the economy and the lack of coordination in establishing economic policies. Through this paper, we aim to offer certain recommendations, which, in our opinion, would lead to solving the issue of inadequate allocation of resources and would also contribute to restoration of the worldwide economy.

  14. The stress and underground environment

    Science.gov (United States)

    Chama, A.

    2009-04-01

    Currently,the program of prevention in occupational health needs mainly to identify occupational hazards and strategy of their prevention.Among these risks,the stress represents an important psycho-social hazard in mental health,which unfortunately does not spare no occupation.My Paper attempts to highlight and to develop this hazard in its different aspects even its regulatory side in underground environment as occupational environment.In the interest of better prevention ,we consider "the information" about the impact of stress as the second prevention efficient and no expensive to speleologists,hygienists and workers in the underground areas. In this occasion of this event in Vienna,we also highlight the scientific works on the stress of the famous viennese physician and endocrinologist Doctor Hans Selye (1907-1982),nicknamed "the father of stress" and note on relation between biological rhythms in this underground area and psychological troubles (temporal isolation) (Jurgen Aschoff’s works and experiences out-of time).

  15. First ATLAS Events Recorded Underground

    CERN Multimedia

    Teuscher, R

    As reported in the CERN Bulletin, Issue No.30-31, 25 July 2005 The ATLAS barrel Tile calorimeter has recorded its first events underground using a cosmic ray trigger, as part of the detector commissioning programme. This is not a simulation! A cosmic ray muon recorded by the barrel Tile calorimeter of ATLAS on 21 June 2005 at 18:30. The calorimeter has three layers and a pointing geometry. The light trapezoids represent the energy deposited in the tiles of the calorimeter depicted as a thick disk. On the evening of June 21, the ATLAS detector, now being installed in the underground experimental hall UX15, reached an important psychological milestone: the barrel Tile calorimeter recorded the first cosmic ray events in the underground cavern. An estimated million cosmic muons enter the ATLAS cavern every 3 minutes, and the ATLAS team decided to make good use of some of them for the commissioning of the detector. Although only 8 of the 128 calorimeter slices ('superdrawers') were included in the trigg...

  16. Development of advanced methods for planning electric energy distribution systems. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Goenen, T.; Foote, B.L.; Thompson, J.C.; Fagan, J.E.

    1979-10-01

    An extensive search was made for the identification and collection of reports published in the open literature which describes distribution planning methods and techniques. In addition, a questionnaire has been prepared and sent to a large number of electric power utility companies. A large number of these companies were visited and/or their distribution planners interviewed for the identification and description of distribution system planning methods and techniques used by these electric power utility companies and other commercial entities. Distribution systems planning models were reviewed and a set of new mixed-integer programming models were developed for the optimal expansion of the distribution systems. The models help the planner to select: (1) optimum substation locations; (2) optimum substation expansions; (3) optimum substation transformer sizes; (4) optimum load transfers between substations; (5) optimum feeder routes and sizes subject to a set of specified constraints. The models permit following existing right-of-ways and avoid areas where feeders and substations cannot be constructed. The results of computer runs were analyzed for adequacy in serving projected loads within regulation limits for both normal and emergency operation.

  17. Research on the Best Root Span of 500kV Substation Frame Based on Finite Element

    Science.gov (United States)

    Chen, Hao; Fang, Qing; Chen, Haoyuan

    2018-01-01

    A-shaped and steel tube structures have been widely applied when designing 500kV substation frame in China. While, compared with steel tube, angle steels have an advantage of easy-transporting, especially in oversea projects. However, researches on substation frame with angle steel were not enough. In order to find out the best root span of 500kV substation frame under similar engineering conditions, using the overseas project substation frame as an example, the substation frames with different root span have been detailed calculated, to find the best root span according to the cost of it. When the height of column is about 30m, the root suggestion value is 6.1m×3.1m. And then, the buckling analysis of the overall structure has been carried out by ANSYS, to find out that the weak part of the structure is in the middle of it. The structural adjustment is carried out for the weak part, including adjusting the web members and the chord members, to obtain a higher bearing capacity of the structure.

  18. Monitoring geomagnetic signals of groundwater movement using multiple underground SQUID magnetometers

    Directory of Open Access Journals (Sweden)

    Henry S.

    2014-01-01

    Full Text Available Groundwater can influence the geomagnetic field measured underground in at least two key ways. The water levels in rock will determine its electrical conductivity, and thus change the magnitude of the telluric currents induced in the rock by changing magnetic fields generated in the ionosphere. This can be studied by using multiple magnetometers at different underground locations. Secondly the flow of water through rock will generate a small magnetic signal, of unknown magnitude, through the electrokinetic effect. SQUID magnetometry has the potential to allow passive studies of groundwater changes in complex systems such as karst. We have monitored geomagnetic signals using two SQUID magnetometers at the LSBB underground laboratory, and set an initial limit on the magnitude of the electrokinetic signal. We now plan to carry out a longer term measurement using three SQUID systems as well as fluxgate sensors to track changes in the gradient of the magnetic field across the underground complex.

  19. Determination of Optimum Network Layout for Low-Energy District Heating Systems with Different Substation Types

    DEFF Research Database (Denmark)

    Tol, Hakan; Svendsen, Svend

    2011-01-01

    In this paper three different District Heating (DH) network types, which comprise substations with storage tank, and with instantaneous heat exchanger (each for domestic hot water production); and booster pumps installed in the beginning of each street at the latter network type, are pointed out...... temperature drop at supply in low heat demand conditions during summer months, are presented with the results of dynamic simulations, carried out in the Termis software with the input data of randomly generated heat demand of consumers in the basis of simultaneity factor effect in each pipe segment at the DH...

  20. Assessment of occupational exposure to magnetic fields in high-voltage substations (154/34.5 kV).

    Science.gov (United States)

    Helhel, S; Ozen, S

    2008-01-01

    This work proposes the survey of magnetic field measurements taken in 154/31.5 kV substations in the city of Antalya for occupational exposure assessment. For measurements, three substations have been taken into account, where four occupants are present for each 8 h of shift, which means 12 occupants are present during the day. Operator desks at three different substations read a lowest magnetic field of 0.3 microT at minimum loaded season and reached up to 1 microT at maximum loaded season, which means operators exposed to a magnetic field of > or = 0.3 microT 8 h d(-1). In switch gear regions, maximum magnetic field reading is 23 microT at minimum loaded season and reached up to 70 microT. Outdoor magnetic field measurement at circuit breaker region goes up to 62 microT with respect to operator heights.

  1. Análise comparativa dos custos de diferentes redes de distribuição de energia elétrica no contexto da arborização urbana Costs of aerial electricity conventional distribution networks, aerial compact distribution networks and underground networks in arboriculture context

    Directory of Open Access Journals (Sweden)

    Giuliana Del Nero Velasco

    2006-08-01

    Full Text Available Com o intuito de estudar as podas feitas em árvores urbanas e analisar novas técnicas possíveis de serem utilizadas para reduzir o número de podas e melhorar a convivência das espécies com a fiação elétrica, além de permitir à árvore desempenhar plenamente suas funções ecológicas, buscou-se levantar dados referentes aos três tipos principais de redes de distribuição de energia elétrica (aérea convencional, aérea compacta e subterrânea, em quatro concessionárias de energia elétrica, a fim de compilá-los em um só trabalho. Foram levantados custos de implantação das redes convencional, compacta e subterrânea, assim como custos de manutenção e de poda de árvores. O custo de implantação de rede convencional (primária e secundária variou de R$54.188,39 a R$67.571,43. O custo de implantação da rede compacta (primária e secundária foi em média R$62.215,99. Já o custo de implantação de uma rede subterrânea é, em média, de R$436.585,04. A rede compacta já é totalmente viável, principalmente por ter custo de implantação praticamente igual à rede convencional e ter custo de manutenção 80% menor. A rede subterrânea, embora com custo de implantação aproximadamente 10 vezes maior quando comparado com o custo da convencional, por ter reduzido custo de manutenção e alta confiabilidade do sistema elétrico, seu uso já pode ser viável em diversas ocasiões.In order to study the pruning carried out in urban trees and analyze new techniques that may be used to reduce pruning, improve the relationship between the species and the networks, and allow trees to fulfill their proper ecological functions, studies concerning the three main types of electric power distribution were carried out: aerial conventional distribution networks, aerial compact distribution networks and underground networks in four electric power companies. The study showed the implementation costs of the three named networks as well as

  2. Underground siting is a nuclear option

    International Nuclear Information System (INIS)

    Dodds, R.K.; Gilbert, P.H.

    1976-01-01

    Underground siting of nuclear power plants is a concept that can be both technologically feasible and economically attractive. To meet both these criteria, however, each underground nuclear plant must be adapted to take full advantage of its location. It cannot be a unit that was designed for the surface and is then buried. Seeking to develop potential commercial programs, Underground Design Consultants (UDC)--a joint venture of Parsons, Brinckerhoff, Quade and Douglas, New York City, Vattenbyggnadsbyran (VBB), Stockholm, Sweden, and Foundation Sciences, Inc., Portland, Oregon--has been studying the siting of nuclear plants underground. UDC has made a presentation to EPRI on the potential for underground siting in the U.S. The summary presented here is based on the experiences of underground nuclear power plants in Halden, Norway; Agesta, Sweden; Chooz, France; and Lucens, Switzerland. Data from another plant in the design phase in Sweden and UDC's own considered judgment were also used

  3. Radon in Brazilian underground mines.

    Science.gov (United States)

    Ayres da Silva, Anna Luiza Marques; Eston, Sérgio Médici; Iramina, Wilson Siguemasa; Francisca, Diego Diegues

    2018-02-14

    Radon is a chemically inert noble radioactive gas found in several radioactive decay chains. In underground mines, especially those that contain or have contained ores associated with uranium-bearing minerals, workers might be exposed to high levels of radon and its decay products (RDP). This work aimed to investigate whether the exposure of workers to radon gas and its progeny has been evaluated in Brazilian non-uranium and non-thorium underground mines. If so, the results and control measures undertaken or recommended to maintain the concentrations under Brazilian occupational exposure limits (OELs) were documented. The adopted methodology consisted of three main phases. The first was an extensive bibliographical survey of the concentration levels of radon and RDP, and the radiation dose estimates, considering measurements made heretofore by various Brazilian researchers and exhibiting original measurement work undertaken by the one of the authors (mine O). In the second phase, the values obtained were compared with OELs. In the third phase, it was verified whether any control measures were undertaken in the mines with high exposure of workers to radon and its progeny, and if so, the adopted controls were determined. Data of radon concentration obtained from 52 campaigns in 40 underground mines were analyzed. The results showed that the assessment of the exposure of workers to radon and its progeny was undertaken in many mines at least once, and that in 62.5% of the mines, when visited for the first time, the radon levels throughout them were below the Brazilian OELs. As expected, the main control measure adopted or recommended was the improvement of the ventilation system. © 2018 IOP Publishing Ltd.

  4. Third symposium on underground mining

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-01-01

    The Third Symposium on Underground Mining was held at the Kentucky Fair and Exposition Center, Louisville, KY, October 18--20, 1977. Thirty-one papers have been entered individually into EDB and ERA. The topics covered include mining system (longwall, shortwall, room and pillar, etc.), mining equipment (continuous miners, longwall equipment, supports, roof bolters, shaft excavation equipment, monitoring and control systems. Maintenance and rebuilding facilities, lighting systems, etc.), ventilation, noise abatement, economics, accidents (cost), dust control and on-line computer systems. (LTN)

  5. Underground storage of nuclear waste

    International Nuclear Information System (INIS)

    Russell, J.E.

    1977-06-01

    The objective of the National Waste Terminal Storage (NWTS) Program is to provide facilities in various deep geologic formations at multiple locations in the United States which will safely dispose of commerical radioactive waste. The NWTS Program is being administered for the Energy Research and Development Administration (ERDA) by the Office of Waste Isolation (OWI), Union Carbide Corporation, Nuclear Division. OWI manages projects that will lead to the location, construction, and operation of repositories, including all surface and underground engineering and facility design projects and technical support projects. 7 refs., 5 figs

  6. The Mounting process and dielectric tests of the Parque Caballero armored substation in SF6(220 Kv); Montaje y pruebas dielectricas de la estacion blindada en gas SF6 (220 kV) 'Parque Caballero'

    Energy Technology Data Exchange (ETDEWEB)

    Decoud, Carlos; Bobadilla, Alberto [ANDE - Administracion Nacional de Electricidad, Assuncion (Paraguay)

    2001-07-01

    This document approaches the aspects referring to the mounting and also dielectric tests for the Parque Caballero armored substation in SF6. This type of installation represents a innovation regarding substations in urban centres. The most relevant items in relation to the mounting process are shown in a summarized way, as well as the aspects related to dielectric tests executed during the substation commissioning.

  7. Electrical distribution studies for the 200 Area tank farms

    Energy Technology Data Exchange (ETDEWEB)

    Fisler, J.B.

    1994-08-26

    This is an engineering study providing reliability numbers for various design configurations as well as computer analyses (Captor/Dapper) of the existing distribution system to the 480V side of the unit substations. The objective of the study was to assure the adequacy of the existing electrical system components from the connection at the high voltage supply point through the transformation and distribution equipment to the point where it is reduced to its useful voltage level. It also was to evaluate the reasonableness of proposed solutions of identified deficiencies and recommendations of possible alternate solutions. The electrical utilities are normally considered the most vital of the utility systems on a site because all other utility systems depend on electrical power. The system accepts electric power from the external sources, reduces it to a lower voltage, and distributes it to end-use points throughout the site. By classic definition, all utility systems extend to a point 5 feet from the facility perimeter. An exception is made to this definition for the electric utilities at this site. The electrical Utility System ends at the low voltage section of the unit substation, which reduces the voltage from 13.8 kV to 2,400, 480, 277/480 or 120/208 volts. These transformers are located at various distances from existing facilities. The adequacy of the distribution system which transports the power from the main substation to the individual area substations and other load centers is evaluated and factored into the impact of the future load forecast.

  8. Underground storage tank management plan

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-09-01

    The Underground Storage Tank (UST) Management Program at the Oak Ridge Y-12 Plant was established to locate UST systems in operation at the facility, to ensure that all operating UST systems are free of leaks, and to establish a program for the removal of unnecessary UST systems and upgrade of UST systems that continue to be needed. The program implements an integrated approach to the management of UST systems, with each system evaluated against the same requirements and regulations. A common approach is employed, in accordance with Tennessee Department of Environment and Conservation (TDEC) regulations and guidance, when corrective action is mandated. This Management Plan outlines the compliance issues that must be addressed by the UST Management Program, reviews the current UST inventory and compliance approach, and presents the status and planned activities associated with each UST system. The UST Management Plan provides guidance for implementing TDEC regulations and guidelines for petroleum UST systems. (There are no underground radioactive waste UST systems located at Y-12.) The plan is divided into four major sections: (1) regulatory requirements, (2) implementation requirements, (3) Y-12 Plant UST Program inventory sites, and (4) UST waste management practices. These sections describe in detail the applicable regulatory drivers, the UST sites addressed under the Management Program, and the procedures and guidance used for compliance with applicable regulations.

  9. Underground storage tank management plan

    International Nuclear Information System (INIS)

    1994-09-01

    The Underground Storage Tank (UST) Management Program at the Oak Ridge Y-12 Plant was established to locate UST systems in operation at the facility, to ensure that all operating UST systems are free of leaks, and to establish a program for the removal of unnecessary UST systems and upgrade of UST systems that continue to be needed. The program implements an integrated approach to the management of UST systems, with each system evaluated against the same requirements and regulations. A common approach is employed, in accordance with Tennessee Department of Environment and Conservation (TDEC) regulations and guidance, when corrective action is mandated. This Management Plan outlines the compliance issues that must be addressed by the UST Management Program, reviews the current UST inventory and compliance approach, and presents the status and planned activities associated with each UST system. The UST Management Plan provides guidance for implementing TDEC regulations and guidelines for petroleum UST systems. (There are no underground radioactive waste UST systems located at Y-12.) The plan is divided into four major sections: (1) regulatory requirements, (2) implementation requirements, (3) Y-12 Plant UST Program inventory sites, and (4) UST waste management practices. These sections describe in detail the applicable regulatory drivers, the UST sites addressed under the Management Program, and the procedures and guidance used for compliance with applicable regulations

  10. Earthquake damage to underground facilities

    Energy Technology Data Exchange (ETDEWEB)

    Pratt, H.R.; Hustrulid, W.A. Stephenson, D.E.

    1978-11-01

    The potential seismic risk for an underground nuclear waste repository will be one of the considerations in evaluating its ultimate location. However, the risk to subsurface facilities cannot be judged by applying intensity ratings derived from the surface effects of an earthquake. A literature review and analysis were performed to document the damage and non-damage due to earthquakes to underground facilities. Damage from earthquakes to tunnels, s, and wells and damage (rock bursts) from mining operations were investigated. Damage from documented nuclear events was also included in the study where applicable. There are very few data on damage in the subsurface due to earthquakes. This fact itself attests to the lessened effect of earthquakes in the subsurface because mines exist in areas where strong earthquakes have done extensive surface damage. More damage is reported in shallow tunnels near the surface than in deep mines. In mines and tunnels, large displacements occur primarily along pre-existing faults and fractures or at the surface entrance to these facilities.Data indicate vertical structures such as wells and shafts are less susceptible to damage than surface facilities. More analysis is required before seismic criteria can be formulated for the siting of a nuclear waste repository.

  11. Earthquake damage to underground facilities

    International Nuclear Information System (INIS)

    Pratt, H.R.; Hustrulid, W.A.; Stephenson, D.E.

    1978-11-01

    The potential seismic risk for an underground nuclear waste repository will be one of the considerations in evaluating its ultimate location. However, the risk to subsurface facilities cannot be judged by applying intensity ratings derived from the surface effects of an earthquake. A literature review and analysis were performed to document the damage and non-damage due to earthquakes to underground facilities. Damage from earthquakes to tunnels, s, and wells and damage (rock bursts) from mining operations were investigated. Damage from documented nuclear events was also included in the study where applicable. There are very few data on damage in the subsurface due to earthquakes. This fact itself attests to the lessened effect of earthquakes in the subsurface because mines exist in areas where strong earthquakes have done extensive surface damage. More damage is reported in shallow tunnels near the surface than in deep mines. In mines and tunnels, large displacements occur primarily along pre-existing faults and fractures or at the surface entrance to these facilities.Data indicate vertical structures such as wells and shafts are less susceptible to damage than surface facilities. More analysis is required before seismic criteria can be formulated for the siting of a nuclear waste repository

  12. A Novel Partial Discharge Localization Method in Substation Based on a Wireless UHF Sensor Array.

    Science.gov (United States)

    Li, Zhen; Luo, Lingen; Zhou, Nan; Sheng, Gehao; Jiang, Xiuchen

    2017-08-18

    Effective Partial Discharge (PD) localization can detect the insulation problems of the power equipment in a substation and improve the reliability of power systems. Typical Ultra-High Frequency (UHF) PD localization methods are mainly based on time difference information, which need a high sampling rate system. This paper proposes a novel PD localization method based on a received signal strength indicator (RSSI) fingerprint to quickly locate the power equipment with potential insulation defects. The proposed method consists of two stages. In the offline stage, the RSSI fingerprint data of the detection area is measured by a wireless UHF sensor array and processed by a clustering algorithm to reduce the PD interference and abnormal RSSI values. In the online stage, when PD happens, the RSSI fingerprint of PD is measured via the input of pattern recognition for PD localization. To achieve an accurate localization, the pattern recognition process is divided into two steps: a preliminary localization is implemented by cluster recognition to reduce the localization region, and the compressed sensing algorithm is used for accurate PD localization. A field test in a substation indicates that the mean localization error of the proposed method is 1.25 m, and 89.6% localization errors are less than 3 m.

  13. Intercomparison of magnetic field measurements near MV/LV transformer substations: methodological planning and results.

    Science.gov (United States)

    Violanti, S; Fraschetta, M; Adda, S; Caputo, E

    2009-12-01

    Within the framework of Environmental Agencies system's activities, coordinated by ISPRA (superior institute for environmental protection and research), a comparison among measurements was designed and accomplished, in order to go into depth on the matter of measurement problems and to evaluate magnetic field at power frequencies. These measurements have been taken near medium voltage /low voltage transformer substation. This project was developed with the contribution of several experts who belong to different Regional Agencies. In three of these regions, substations having specific international standard characteristics were chosen; then a measurement and data analysis protocol was arranged. Data analysis showed a good level of coherence among results obtained by different laboratories. However, a range of problems emerged, either during the protocol predisposition and definition of the data analysis procedure or during the execution of measures and data reprocessing, because of the spatial and temporal variability of magnetic field. These problems represent elements of particular interest in determining a correct measurement methodology, whose purpose is the comparison with limits of exposure, attention values and quality targets.

  14. Electrical energy statistics for France

    International Nuclear Information System (INIS)

    2009-07-01

    In 2008, national electrical consumption reached 494.5 TWh, an increase of 2.9 % compared with 2007 (480.4 TWh). Adjusted for winter and summer climate contingencies and leap year, its evolution rate compared with 2007 is +1.3 % Consumption by business and private customers came to 198.0 TWh, an increase of 5.9 % compared with 2007 (187.0 TWh); consumption by Large-scale industry and SME/SMIs came to 263.0 TWh, an increase of 0.7 % compared with 2007 (261.3 TWh). Generation in France came to 549.1 TWh, as in 2006, an increase of 4.3 TWh or +0.8 % compared with 2007 (544.8 TWh). Hydro-electric generation reached 68.0 TWh, an increase of 7.5 % compared with 2007 (63.3 TWh). Renewable energy sources generation but hydro reached 9.7 TWh, an increase of 23.8 % compared with 2007 (7.8 TWh), mainly due to an increase of 37.5 % of wind energy (5.6 TWh in 2008 compared with 4.0 TWh in 2007). This progression is coherent with the increase of 48% of the installed capacity for wind generation. Nuclear generation came to 418.3 TWh in 2008, a decrease of 0.1 % compared with 2007 (418.6 TWh). Fossil thermal generation came to 53.1 TWh, a decrease of 3.5 % compared with 2007 (55.1 TWh). The heaviest load in terms of capacity reaches 92.4 GW during winter 2008/2009. Its evolution rate compared with 2007 is +3.8 % with a temperature lower by 2.2 deg. C. Since 2001, the heaviest load in winter has increased by 16% whereas the national electrical consumption has increased by 10%. The year 2008 is marked by the commissioning of the 400 kV line VIGY-MARLENHEIM. Besides, the underground circuits lengths grow by 118 km over the entire network. In terms of physical exchanges of electrical energy between France and the neighbouring countries France exported a net total of 48.0 TWh, a decrease of 15.4 % compared with 2007 (56.7 TWh). Contractual exchanges with foreign countries came to a cumulative value for exports and imports of 116.2 TWh, an increase of 5.1 % compared with 2007 (110.5 TWh

  15. Capital Subsidies and the Underground Economy

    DEFF Research Database (Denmark)

    Busato, Francesco; Chiarini, Bruno; Angelis, Pasquale de

    In this paper we investigate the effects of different fiscal policies on the firm choice to produce underground. We consider a tax evading firm operating simultaneously both in the regular and in the underground economy. We suggest that such a kind of firm, referred to as moonlighting firm, is ab...

  16. A review of international underground laboratory developments

    International Nuclear Information System (INIS)

    Cheng Jianping; Yue Qian; Wu Shiyong; Shen Manbin

    2011-01-01

    Underground laboratories are essential for various important physics areas such as the search for dark matter, double beta decay, neutrino oscillation, and proton decay. At the same time, they are also a very important location for studying rock mechanics, earth structure evolution,and ecology. It is essential for a nation's basic research capability to construct and develop underground laboratories. In the past, China had no high-quality underground laboratory,in particular no deep underground laboratory,so her scientists could not work independently in major fields such as the search for dark matter,but had to collaborate with foreign scientists and share the space of foreign underground laboratories. In 2009, Tsinghua university collaborated with the Ertan Hydropower Development Company to construct an extremely deep underground laboratory, the first in China and currently the deepest in the world, in the Jinping traffic tunnel which was built to develop hydropower from the Yalong River in Sichuan province. This laboratory is named the China Jinping Underground Laboratory (CJPL) and formally opened on December 12, 2010. It is now a major independent platform in China and can host various leading basic research projects. We present a brief review of the development of various international underground laboratories,and especially describe CJPL in detail. (authors)

  17. Underground laboratories in Japan and North America

    International Nuclear Information System (INIS)

    Sobel, Henry W

    2006-01-01

    There is a blossoming demand for deep underground laboratory space to satisfy the expanding interest in experiments that require significant cosmic-ray shielding. I'll briefly describe the existing deep facilities and their plans for expansion. I will also discuss the planning for a new major underground facility in the U.S

  18. Dewatering pump control in underground coal mines

    International Nuclear Information System (INIS)

    Anthony, Kim M.

    2012-01-01

    An underground coal mine roadway dewatering network is a highly variable, constantly changing system. Pumps used in this environment need to achieve a wide range of duties that may change regularly. This article discusses the use of and preferred methods in the context of an Australian underground coal mine with conditions particular to this industry.

  19. UNDERGROUND ECONOMY, INFLUENCES ON NATIONAL ECONOMIES

    Directory of Open Access Journals (Sweden)

    CEAUȘESCU IONUT

    2015-04-01

    Full Text Available The purpose of research is to improve the understanding of nature underground economy by rational justification of the right to be enshrined a reality that, at least statistically, can no longer be neglected. So, we propose to find the answer to the question: has underground economy to stand-alone?

  20. Damage caused to houses and equipment by underground nuclear explosions

    International Nuclear Information System (INIS)

    Delort, F.; Guerrini, C.

    1969-01-01

    A description is given of the damaged caused to various structures, buildings, houses, mechanical equipment and electrical equipment by underground nuclear explosions in granite. For each type of equipment or building are given the limiting distances for a given degree of damage. These distances have been related to a parameter characterizing the movement of the medium; it is thus possible to generalize the results obtained in granite, for different media. The problem of estimating the damage caused at a greater distance from the explosion is considered. (authors) [fr

  1. Use of ground penetrating radar in underground coal mining

    Science.gov (United States)

    Ralston, Johnathon C.; Hainsworth, David W.

    2000-04-01

    This paper reports on a novel application of ground penetrating radar to a longwall steering problem in the coal mining industry. The main goal of the work was to determine whether a radar-based system could be used to detect coal-rock interfaces in order to establish a suitable mining horizon within the coal seam. We investigated the feasibility of the radar unit and determined that a positive correlation exists between the radar data and known coal-rock interface geology. We also highlight some of the unique challenges encountered when attempting to develop electrical equipment that is suitable for hazardous underground coal mining environments.

  2. 30 CFR 57.6602 - Static electricity dissipation during loading.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Static electricity dissipation during loading... MINES Explosives Extraneous Electricity-Surface and Underground § 57.6602 Static electricity dissipation... generates a static electricity hazard— (a) An evaluation of the potential static electricity hazard shall be...

  3. 30 CFR 57.6400 - Compatibility of electric detonators.

    Science.gov (United States)

    2010-07-01

    ... Electric Blasting-Surface and Underground § 57.6400 Compatibility of electric detonators. All electric detonators to be fired in a round shall be from the same manufacturer and shall have similar electrical... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Compatibility of electric detonators. 57.6400...

  4. National Maglev initiative: California line electric utility power system requirements

    Science.gov (United States)

    Save, Phil

    1994-05-01

    The electrical utility power system requirements were determined for a Maglev line from San Diego to San Francisco and Sacramento with a maximum capacity of 12,000 passengers an hour in each direction at a speed of 300 miles per hour, or one train every 30 seconds in each direction. Basically the Maglev line requires one 50-MVA substation every 12.5 miles. The need for new power lines to serve these substations and their voltage levels are based not only on equipment loading criteria but also on limitations due to voltage flicker and harmonics created by the Maglev system. The resulting power system requirements and their costs depend mostly on the geographical area, urban or suburban with 'strong' power systems, or mountains and rural areas with 'weak' power systems. A reliability evaluation indicated that emergency power sources, such as a 10-MW battery at each substation, were not justified if sufficient redundancy is provided in the design of the substations and the power lines serving them. With a cost of $5.6 M per mile, the power system requirements, including the 12-kV DC cables and the inverters along the Maglev line, were found to be the second largest cost component of the Maglev system, after the cost of the guideway system ($9.1 M per mile), out of a total cost of $23 M per mile.

  5. National Maglev initiative: California line electric utility power system requirements

    Science.gov (United States)

    Save, Phil

    1994-01-01

    The electrical utility power system requirements were determined for a Maglev line from San Diego to San Francisco and Sacramento with a maximum capacity of 12,000 passengers an hour in each direction at a speed of 300 miles per hour, or one train every 30 seconds in each direction. Basically the Maglev line requires one 50-MVA substation every 12.5 miles. The need for new power lines to serve these substations and their voltage levels are based not only on equipment loading criteria but also on limitations due to voltage flicker and harmonics created by the Maglev system. The resulting power system requirements and their costs depend mostly on the geographical area, urban or suburban with 'strong' power systems, or mountains and rural areas with 'weak' power systems. A reliability evaluation indicated that emergency power sources, such as a 10-MW battery at each substation, were not justified if sufficient redundancy is provided in the design of the substations and the power lines serving them. With a cost of $5.6 M per mile, the power system requirements, including the 12-kV DC cables and the inverters along the Maglev line, were found to be the second largest cost component of the Maglev system, after the cost of the guideway system ($9.1 M per mile), out of a total cost of $23 M per mile.

  6. Sickness absence from 1978 to 1992 of Electricite de France (EDF) workers exposed to ELF-EMF: the substation group

    International Nuclear Information System (INIS)

    Souques, M.; Dab, W.; Lambrozo, J.; Chevalier, A.; Coing, F.

    1996-01-01

    Electromagnetic fields are suspected of many health effects, including cancers, immunity and fertility disorders, congenital malformations, suicides and depression.... Although the results of all studies are contradictory and no biological mechanism has been found, populations are concerned about this matter. This study analyzes the absence from work of some EDF employees who are a priori the most professionally exposed to ELF EMF. Absence from work is taken as an health indicator. Although it is not specific, it can be predictive of serious health problems. The specific context of EDF has made it possible to collect and analyze the medical aspect of absence from work, that is rare in France. We were interested with employees working with high voltage (over 90 kV). Three job categories have been selected: live line workers, substation maintenance workers and substation exploitation workers (called in the company the ATEX). The first group concerned the live linemen and the results were exposed previously. It appeared they had more accidents at work, but this was more related to the job of lineman rather than to the EMF exposure. Nevertheless, substation workers have an exposure less intensive but longer than live linemen. We present here the result about the absenteeism of the substation workers, maintenance and exploitation. (author)

  7. Antena Kupu - Kupu sebagai Sensor Ultra High Frequency (UHF) untuk Mendeteksi Partial Discharge pada Gas Insulation Substation

    OpenAIRE

    Andre, Hanalde; Khayam, Umar

    2013-01-01

    Penggunaan antena sebagai penerima gelombang elektromagnetik dapat digunakan sebagai alat untuk mendeteksi kegiatan partial discharge (PD) yang terjadi pada paralatan tegangan tinggi. Khususnya pada gas insulation substation (GIS), karakteristik gelombang elektromagnetik yang dihasilkan terletak pada rentang ultra high frequency (UHF) dalam rentang 300 MHz – 3 GHz. Karakteristik antena ultra wide band (UWB) diperlukan untuk mendeteksi PD pada rentang yang lebar. Perancangan antena dilakukan...

  8. First operation experiences from a 30 kV 104 MVA HTS power cable installed in a utility substation

    DEFF Research Database (Denmark)

    Willen, D.; Hansen, F.; Daumling, M.

    2002-01-01

    realistic conditions in the substation of Amager (AMK). Approximately 50 000 private and business customers are supplied from this cable. The load can be adjusted from 20% to 100% of the power supplied and the number of branches connected can be altered. This and other early HTS power installations...

  9. Radionuclide behavior at underground environment

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Phil Soo; Park, Chung Kyun; Keum, Dong Kwon; Cho, Young Hwan; Kang, Moon Ja; Baik, Min Hoon; Hahn, Kyung Won; Chun, Kwan Sik; Park, Hyun Soo

    2000-03-01

    This study of radionuclide behavior at underground environment has been carried out as a part of the study of high-level waste disposal technology development. Therefore, the main objectives of this project are constructing a data-base and producing data for the safety assessment of a high-level radioactive waste, and verification of the objectivity of the assessment through characterization of the geochemical processes and experimental validation of the radionuclide migration. The various results from the this project can be applicable to the preliminary safety and performance assessments of the established disposal concept for a future high-level radioactive waste repository. Providing required data and technical basis for assessment methodologies could be a direct application of the results. In a long-term view, the results can also be utilized as a technical background for the establishment of government policy for high-level radioactive waste disposal.

  10. Underground radioactive waste disposal concept

    International Nuclear Information System (INIS)

    Frgic, L.; Tor, K.; Hudec, M.

    2002-01-01

    The paper presents some solutions for radioactive waste disposal. An underground disposal of radioactive waste is proposed in deep boreholes of greater diameter, fitted with containers. In northern part of Croatia, the geological data are available on numerous boreholes. The boreholes were drilled during investigations and prospecting of petroleum and gas fields. The available data may prove useful in defining safe deep layers suitable for waste repositories. The paper describes a Russian disposal design, execution and verification procedure. The aim of the paper is to discuss some earlier proposed solutions, and present a solution that has not yet been considered - lowering of containers with high level radioactive waste (HLW) to at least 500 m under the ground surface.(author)

  11. Swedish mines. Underground exploitation methods

    International Nuclear Information System (INIS)

    Paucard, A.

    1960-01-01

    Between 1949 and 1957, 10 engineers of the Mining research and exploitation department of the CEA visited 17 Swedish mines during 5 field trips. This paper presents a compilation of the information gathered during these field trips concerning the different underground mining techniques used in Swedish iron mines: mining with backfilling (Central Sweden and Boliden mines); mining without backfilling (mines of the polar circle area). The following techniques are described successively: pillar drawing and backfilled slices (Ammeberg, Falun, Garpenberg, Boliden group), sub-level pillar drawing (Grangesberg, Bloettberget, Haeksberg), empty room and sub-level pillar drawing (Bodas, Haksberg, Stripa, Bastkarn), storage chamber pillar drawing (Bodas, Haeksberg, Bastkarn), and pillar drawing by block caving (ldkerberget). Reprint of a paper published in Revue de l'Industrie Minerale, vol. 41, no. 12, 1959 [fr

  12. Toxic hazards of underground excavation

    International Nuclear Information System (INIS)

    Smith, R.; Chitnis, V.; Damasian, M.

    1982-09-01

    Inadvertent intrusion into natural or man-made toxic or hazardous material deposits as a consequence of activities such as mining, excavation or tunnelling has resulted in numerous deaths and injuries in this country. This study is a preliminary investigation to identify and document instances of such fatal or injurious intrusion. An objective is to provide useful insights and information related to potential hazards due to future intrusion into underground radioactive-waste-disposal facilities. The methodology used in this study includes literature review and correspondence with appropriate government agencies and organizations. Key categories of intrusion hazards are asphyxiation, methane, hydrogen sulfide, silica and asbestos, naturally occurring radionuclides, and various mine or waste dump related hazards

  13. Radioactive wastes: underground laboratories implantation

    International Nuclear Information System (INIS)

    Bataille, Ch.

    1997-01-01

    This article studies the situation of radioactive waste management, more especially the possible storage in deep laboratories. In front of the reaction of public opinion relative to the nuclear waste question, it was essential to begin by a study on the notions of liability, transparence and democracy. At the beginning, it was a matter of underground researches with a view to doing an eventual storage of high level radioactive wastes. The Parliament had to define, through the law, a behaviour able to come to the fore for anybody. A behaviour which won recognition from authorities, from scientists, from industrial people, which guarantees the rights of populations confronted to a problem whom they were not informed, on which they received only few explanations. (N.C.)

  14. Seismic verification of underground explosions

    International Nuclear Information System (INIS)

    Glenn, L.A.

    1985-06-01

    The first nuclear test agreement, the test moratorium, was made in 1958 and lasted until the Soviet Union unilaterally resumed testing in the atmosphere in 1961. It was followed by the Limited Test Ban Treaty of 1963, which prohibited nuclear tests in the atmosphere, in outer space, and underwater. In 1974 the Threshold Test Ban Treaty (TTBT) was signed, limiting underground tests after March 1976 to a maximum yield of 250 kt. The TTBT was followed by a treaty limiting peaceful nuclear explosions and both the United States and the Soviet Union claim to be abiding by the 150-kt yield limit. A comprehensive test ban treaty (CTBT), prohibiting all testing of nuclear weapons, has also been discussed. However, a verifiable CTBT is a contradiction in terms. No monitoring technology can offer absolute assurance that very-low-yield illicit explosions have not occurred. The verification process, evasion opportunities, and cavity decoupling are discussed in this paper

  15. Toxic hazards of underground excavation

    Energy Technology Data Exchange (ETDEWEB)

    Smith, R.; Chitnis, V.; Damasian, M.; Lemm, M.; Popplesdorf, N.; Ryan, T.; Saban, C.; Cohen, J.; Smith, C.; Ciminesi, F.

    1982-09-01

    Inadvertent intrusion into natural or man-made toxic or hazardous material deposits as a consequence of activities such as mining, excavation or tunnelling has resulted in numerous deaths and injuries in this country. This study is a preliminary investigation to identify and document instances of such fatal or injurious intrusion. An objective is to provide useful insights and information related to potential hazards due to future intrusion into underground radioactive-waste-disposal facilities. The methodology used in this study includes literature review and correspondence with appropriate government agencies and organizations. Key categories of intrusion hazards are asphyxiation, methane, hydrogen sulfide, silica and asbestos, naturally occurring radionuclides, and various mine or waste dump related hazards.

  16. Locomotive track detection for underground

    Science.gov (United States)

    Ma, Zhonglei; Lang, Wenhui; Li, Xiaoming; Wei, Xing

    2017-08-01

    In order to improve the PC-based track detection system, this paper proposes a method to detect linear track for underground locomotive based on DSP + FPGA. Firstly, the analog signal outputted from the camera is sampled by A / D chip. Then the collected digital signal is preprocessed by FPGA. Secondly, the output signal of FPGA is transmitted to DSP via EMIF port. Subsequently, the adaptive threshold edge detection, polar angle and radius constrain based Hough transform are implemented by DSP. Lastly, the detected track information is transmitted to host computer through Ethernet interface. The experimental results show that the system can not only meet the requirements of real-time detection, but also has good robustness.

  17. Underground coal mining section data

    Science.gov (United States)

    Gabrill, C. P.; Urie, J. T.

    1981-01-01

    A set of tables which display the allocation of time for ten personnel and eight pieces of underground coal mining equipment to ten function categories is provided. Data from 125 full shift time studies contained in the KETRON database was utilized as the primary source data. The KETRON activity and delay codes were mapped onto JPL equipment, personnel and function categories. Computer processing was then performed to aggregate the shift level data and generate the matrices. Additional, documented time study data were analyzed and used to supplement the KETRON databased. The source data including the number of shifts are described. Specific parameters of the mines from which there data were extracted are presented. The result of the data processing including the required JPL matrices is presented. A brief comparison with a time study analysis of continuous mining systems is presented. The procedures used for processing the source data are described.

  18. Underground repository for radioactive wastes

    International Nuclear Information System (INIS)

    Cassibba, R.O.

    1989-01-01

    In the feasibility study for an underground repository in Argentina, the conceptual basis for the final disposal of high activity nuclear waste was set, as well as the biosphere isolation, according to the multiple barrier concept or to the engineering barrier system. As design limit, the container shall act as an engineering barrier, granting the isolation of the radionuclides for approximately 1000 years. The container for reprocessed and vitrified wastes shall have three metallic layers: a stainless steel inner layer, an external one of a metal to be selected and a thick intermediate lead layer preselected due to its good radiological protection and corrosion resistance. Therefore, the study of the lead corrosion behaviour in simulated media of an underground repository becomes necessary. Relevant parameters of the repository system such as temperature, pressure, water flux, variation in salt concentrations and oxidants supply shall be considered. At the same time, a study is necessary on the galvanic effect of lead coupled with different candidate metals for external layer of the container in the same experimental conditions. Also temporal evaluation about the engineering barrier system efficiency is presented in this thesis. It was considered the extrapolated results of corrosion rates and literature data about the other engineering barriers. Taking into account that corrosion is of a generalized type, the integrity of the lead shall be maintained for more than 1000 years and according to temporal evaluation, the multiple barrier concept shall retard the radionuclide dispersion to the biosphere for a period of time between 10 4 and 10 6 years. (Author) [es

  19. Seismic effects on underground openings

    International Nuclear Information System (INIS)

    Marine, I.W.; Pratt, H.R.; Wahi, K.K.; Science Applications, Inc., La Jolla, CA; Science Applications, Inc., Albuquerque, NM)

    1982-01-01

    Numerical modeling techniques were used to determine the conditions required for seismic waves generated by an earthquake to cause instability to an underground opening or create fracturing and joint movement that would lead to an increase in the permeability of the rock mass. Three different rock types (salt, granite, and shale) were considered as host media for the repository located at a depth of 600 m. Special material models were developed to account for the nonlinear material behavior of each rock type. The sensitivity analysis included variations in the in situ stress ratio, joint geometry, and pore pressures, and the presence or absence of large fractures. Three different sets of earthquake motions were used to excite the rock mass. The methodology applied was found to be suitable for studying the effects of earthquakes on underground openings. In general, the study showed that moderate earthquakes (up to 0.41 g) did not cause instability of the tunnel or major fracturing of the rock mass; however, a tremor with accelerations up to 0.95 g was amplified around the tunnel, and fracturing occurred as a result of the seismic loading in salt and granite. In situ stress is a critical parameter in determining the subsurface effects of earthquakes but is nonexistent in evaluating the cause for surface damage. In shale with the properties assumed, even the moderate seismic load resulted in tunnel instability. These studies are all generic in nature and do not abrogate the need for site and design studies for specific facilities. 30 references, 14 figures, 8 tables

  20. FAB - Underwater and underground electric connection between France and Great Britain via Aurigny. File of presentation of the project and of its investigation area. Project synthesis. Impact study constituting an incidence document under the Law on Water. Ground brochure + Sea brochure. Non technical summary. Deliberated opinion of the Environmental Authority on the underwater and underground electrical interconnection between France and Great-Britain via Aurigny (FAB)

    International Nuclear Information System (INIS)

    2014-11-01

    This document gathers several reports. The first one indicates the actors involved in the project of electrical interconnection between France and Great-Britain via Aurigny, presents various technical aspects and works of this project, and proposes a definition and a description of the concerned area. The second report proposes a synthetic presentation of the project: agreement process, project interest, project definition and equipment locations, project technical components and aspects, onshore and offshore environmental aspects, project status and planning. The third report analyses the various onshore aspects of the interconnection project: project description, initial situation of the environment, analysis of the project effects on the environment and on health, analysis of cumulated effects with other known projects, sketches of examined substitution solutions and reasons for the selection of the project, elements of analysis of compliance with land uses and various planning documents, measures aimed at avoiding, reducing or compensating project effects, methods to assess initial status and effects, faced difficulties. The fourth report addresses the same issues as the previous one but for offshore aspects. The fifth report is a non technical summarised presentation of the project which presents the French side, describes the elaboration approach, the offshore and onshore legs of the project, an assessment of impacts on Natura 2000 sites. It notably contains several detailed geographical and geological maps to illustrate and to highlight the various environmental, geological, economic, social, urban or landscape impacts. The last document is the detailed opinion of the Environmental Authority on this project. It addresses the context, the project principle, implementation and cost, environmental stakes and challenges, and impacts

  1. Numerical modelling and experimental measurements for a low-temperature district heating substation for instantaneous preparation of DHW with respect to service pipes

    DEFF Research Database (Denmark)

    Brand, Marek; Thorsen, Jan Eric; Svendsen, Svend

    2012-01-01

    as much as possible. This requires a review and improvement of a DH network, in-house substations, and the whole domestic hot water (DHW) supply system, with the focus on user comfort, hygiene, overall cost and energy efficiency. This paper describes some practical approaches to the implementation of low......-temperature district heating (LTDH) with an entry-to-substation temperature around 50 °C. To this end we developed a numerical model for an instantaneous LTDH substation that takes into consideration the effect of service pipes. The model has been verified and can be used for the further optimization of the whole...

  2. Feasibility study: Application of RCM techniques for substation maintenance at the Bonneville Power Administration

    Energy Technology Data Exchange (ETDEWEB)

    Purucker, S.L.; Tonn, B.E.; Goeltz, R.T.; James, R.D.; Kercel, S.; Rizy, D.T.; Simpson, M.L.; Van Dyke, J.W.

    1992-05-28

    This feasibility study examines reliability centered maintenance (RCM) as it applies to Bonneville Power Administrations (BPA) substation maintenance program. Reliability techniques are examined in evaluated. Existing BPA equipment maintenance procedures are documented. Equipment failure history is considered. Economic impacts are estimated. Various equipment instrumentation methods are reviewed. Based on this analysis a prototype system is proposed. The prototype will be implemented in two phases. Phase 1 is to be completed in 1992, it includes instrumenting one power transformer and one oil circuit breaker. Software development will focus on displaying data. Phase 2 is to be completed the following year. The remaining transformers and breakers will be instrumented during the second phase. Software development will focus on predictive maintenance techniques and maintenance decision support.

  3. Seminoe-Kortes transmission line/substation consolidation project, Carbon County, Wyoming

    Energy Technology Data Exchange (ETDEWEB)

    1990-07-01

    The existing switchyards at Western Area Power Administration's (WESTERN) Seminoe and Kortes facilities, located approximately 40 miles northeast of Rawlines, Carbon County, Wyoming, were constructed in 1939 and 1951, respectively. The circuit breakers at these facilities are beyond or approaching their service life and need to be replaced. In addition, the switchyards have poor access for maintenance and replacement of equipment, and their locations create potential for oil spills into the North Platte River. WESTERN is proposing to consolidate the switchyard facilities into one new substation to provide easier access, restore proper levels of system reliability, and decrease the potential for oil contamination of the river. This environmental assessment (EA) was prepared to evaluate the impacts of the proposed Seminoe-Kortes Consolidation Project. 57 refs., 12 figs., 8 tabs.

  4. Study on ventilation and noise reduction in the main transformer room in indoor substation

    Directory of Open Access Journals (Sweden)

    Hu Sheng

    2016-01-01

    Full Text Available The noise emission should be considered in the ventilation and cooling design for the main transformer room of indoor substation. In this study, based on Soundplan software, effects of four common ventilation and cooling schemes on the cooling and sound insulation were compared. The research showed that the region with low noise requirement, the ventilation could be set on the outer wall or on the door of the main transformer room, while the region with high noise requirement, air inlet muffler or ventilation through the cable interlayer under the main transformer room must be used. All of the four kinds of ventilation schemes, ventilation through the cable interlayer is the best in cooling and noise reduction.

  5. Development of a blocking logic checking apparatus for substation measurement and control devices

    Directory of Open Access Journals (Sweden)

    Chen Li

    2017-01-01

    Full Text Available After transforming substation measurement and control devices, the traditional method of blocking logic check needs to go back and forth among the measurement and control devices, and repeatedly connect a large number of wires, which lead to tedious operation and low efficiency. This paper developed a logic verification device based on 4G wireless communication, which used the Modbus/TCP transport protocol to access Ethernet, to complete the real-time data communication with the mobile control terminal. And this paper made a request to the logic controller according to practicality and cost. And the terminal software interface was designed by the orthogonal experimental design idea. The development of this device provided a new and efficient method for logic verification.

  6. Investigation of Leakage Current Waveforms Recorded in a Coastal High Voltage Substation

    Directory of Open Access Journals (Sweden)

    E. Thalassinakis

    2011-06-01

    Full Text Available Leakage current monitoring is a widely employed technique to monitor the performance of outdoor insulation. The evaluation of leakage current waveforms recorded in the field, offers significant information since insulation’s performance is strongly linked with local conditions, and the waveforms’ shape correlate to different types of surface activity. In this paper, an investigation of leakage current waveforms recorded in a 150 kV coastal Substations suffering which suffers intense marine pollution is presented. Investigation of the recorded waveforms verified the basic waveform shapes described in the literature. Further, several variations of the basic types and complex waveforms, as well as field related waveforms, are presented. The need for added categorization criteria in the case of field measurements is discussed.

  7. Audible Noise Measurement and Analysis of the Main Power Apparatus in UHV GIS Substations

    Directory of Open Access Journals (Sweden)

    Zhou Nian Guang

    2016-01-01

    Full Text Available Investigation of audible noise characteristics of the main power apparatus in UHV GIS substations provides essential statistics for the noise prediction and control. Noise pressure level, spectrum and attenuation characteristics of the main transformers and high voltage (HV reactors are measured and analyzed in this paper. The result shows that the main transformer and HV reactor have identical A-weighted equivalent sound pressure level. The medium- and low-frequency noises are the primary components in the spectral. More attention should be paid to the low-frequency bands in the noise control process. The noise of cooling fan has a large influence on that of the main transformer. Without the consideration of corona noise, the average A-weighted sound pressure level shows an overall decreasing trend with the increase of the propagation distance. Obvious interference phenomenon of the noises at 100 and 200Hz exists in the noise propagation process.

  8. Underground science initiatives at Los Alamos

    International Nuclear Information System (INIS)

    Simmons, L.M. Jr.

    1985-01-01

    Recently, the Los Alamos National Laboratory has proposed two major new initiatives in underground science. Following the dissolution of the original gallium solar neutrino collaboration, Los Alamos has formed a new North American collaboration. We briefly review the rationale for solar neutrino research, outline the proposal and new Monte Carlo simulations, and describe the candidate locations for the experiment. Because there is no dedicated deep underground site in North America suitable for a wide range of experiments, Los Alamos has conducted a survey of possible sites and developed a proposal to create a new National Underground Science Facility. This paper also reviews that proposal

  9. Review of technical features in underground laboratories

    Science.gov (United States)

    Ianni, Aldo

    2017-10-01

    Deep underground laboratories are multidisciplinary research infrastructures. The main feature of these laboratories is the reduced cosmic ray muons flux. This characteristic allows searching for rare events such as proton decay, dark matter particles or neutrino interactions. However, biology in extreme environments and geophysics are also studied underground. A number of ancillary facilities are critical to properly operate low background experiments in these laboratories. In this work we review the main characteristics of deep underground laboratories and discuss a few of the low background facilities.

  10. Supervisory control system based on PC applied to substations automatization of and to regional operation centers of distribution networks; Sistema de control supervisorio basado en PC aplicado en automatizacion de subestaciones y centros de operacion regional de redes de distribucion

    Energy Technology Data Exchange (ETDEWEB)

    Picasso B, Cuitlahuac [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Astorga Q, Clemente [Luz y Fuerza del Centro (Mexico)

    2003-07-01

    In order to increase the services quality in the electrical energy, to improve the process of identification of energy losses, to increase the equipment efficiency, to count on more complete statistics of profiles of load consumptions, among other applications, the Compania de Luz y Fuerza del Centro (LyFC) carries out the modernization in automatization of substations and regional operation centers of distribution networks. The technological base to make these programs requires automating the operative schemes of the substation and distribution centers that supervise the events of the electrical process. In this article the main results of the development and integration of master stations based on PC, that were made in the Instituto de Investigaciones Electricas (IIE) and that have been integrated in the electrical company LyFC are presented. [Spanish] Con el proposito de incrementar la calidad de los servicios en la energia electrica, mejorar el proceso de identificacion de perdidas de energia, aumentar la eficiencia de los equipos, contar con estadisticas mas completas de perfiles de consumos de carga, entre otras aplicaciones, la Compania de Luz y Fuerza del Centro (LyFC) lleva a cabo la modernizacion en automatizacion de subestaciones y centros de operacion regional de redes electricas de distribucion. La base tecnologica para realizar estos programas, requiere de automatizar los esquemas operativos de la subestacion y centros de distribucion que supervisan los eventos del proceso electrico. En este articulo se presentan los principales resultados del desarrollo e integracion de estaciones maestras basadas en PC, que se realizaron en el Instituto de Investigaciones Electricas (IIE) y que se han integrado en la compania electrica LyFC.

  11. Study of seismic response and vibration control of High voltage electrical equipment damper based on TMD

    Science.gov (United States)

    Liu, Chuncheng; Wang, Chongyang; Mao, Long; Zha, Chuanming

    2016-11-01

    Substation high voltage electrical equipment such as mutual inductor, circuit interrupter, disconnecting switch, etc., has played a key role in maintaining the normal operation of the power system. When the earthquake disaster, the electrical equipment of the porcelain in the transformer substation is the most easily to damage, causing great economic losses. In this paper, using the method of numerical analysis, the establishment of a typical high voltage electrical equipment of three dimensional finite element model, to study the seismic response of a typical SF6 circuit breaker, at the same time, analysis and contrast the installation ring tuned mass damper (TMD damper for short), by changing the damper damping coefficient and the mass block, install annular TMD vibration control effect is studied. The results of the study for guiding the seismic design of high voltage electrical equipment to provide valuable reference.

  12. Electrical energy in France in 2009

    International Nuclear Information System (INIS)

    2009-12-01

    The figures presented on this document account for the electricity flows recorded in Metropolitan France, including Corsica. Contents: national consumption; physical exchanges with foreign countries; electrical energy balance in France in 2009; net generation; noteworthy data for the year 2009 (daily maximum values of national consumption, thermal generation, hydro-electric generation, wind generation and balance of physical exchanges); electricity market: cross-borders contractual exchanges, balance responsible entities (Energy amount exchanged between balance responsible entities through the block exchange notifications), balancing mechanism (global amount of energy activated upwards and downwards), daily market coupling; power facilities: generating facilities in France (Nuclear, Fossil fuel thermal, Hydro-electric, Wind and Other renewable energy sources), transmission lines owned by RTE (circuit length in operation), transmission - transformers owned by RTE (installed capacity in operation); main transmission facilities commissioned during the year 2009 (substations connected to the RTE network and new or refurbished circuits)

  13. Borehole induction logging for the Dynamic Underground Stripping Project LLNL gasoline spill site

    International Nuclear Information System (INIS)

    Boyd, S.; Newmark, R.; Wilt, M.

    1994-01-01

    Borehole induction logs were acquired for the purpose of characterizing subsurface physical properties and monitoring steam clean up activities at the Lawrence Livermore National Laboratory. This work was part of the Dynamic Underground Stripping Project's demonstrated clean up of a gasoline spin. The site is composed of unconsolidated days, sands and gravels which contain gasoline both above and below the water table. Induction logs were used to characterize lithology, to provide ''ground truth'' resistivity values for electrical resistance tomography (ERT), and to monitor the movement of an underground steam plume used to heat the soil and drive volatile organic compounds (VOCs) to the extraction wells

  14. Deep underground reactor (passive heat removal of LWR with hard neutron energy spectrum)

    International Nuclear Information System (INIS)

    Hiroshi, Takahashi

    2001-01-01

    To run a high conversion reactor with Pu-Th fueled tight fueled assembly which has a long burn-up of a fuel, the reactor should be sited deep underground. By putting the reactor deep underground heat can be removed passively not only during a steady-state run and also in an emergency case of loss of coolant and loss of on-site power; hence the safety of the reactor can be much improved. Also, the evacuation area around the reactor can be minimized, and the reactor placed near the consumer area. This approach reduces the cost of generating electricity by eliminating the container building and shortening transmission lines. (author)

  15. Steam jacket dynamics in underground coal gasification

    Science.gov (United States)

    Otto, Christopher; Kempka, Thomas

    2017-04-01

    Underground coal gasification (UCG) has the potential to increase the world-wide hydrocarbon reserves by utilization of deposits not economically mineable by conventional methods. In this context, UCG involves combusting coal in-situ to produce a high-calorific synthesis gas, which can be applied for electricity generation or chemical feedstock production. Apart from high economic potentials, in-situ combustion may cause environmental impacts such as groundwater pollution by by-product leakage. In order to prevent or significantly mitigate these potential environmental concerns, UCG reactors are generally operated below hydrostatic pressure to limit the outflow of UCG process fluids into overburden aquifers. This pressure difference effects groundwater inflow into the reactor and prevents the escape of product gas. In the close reactor vicinity, fluid flow determined by the evolving high reactor temperatures, resulting in the build-up of a steam jacket. Numerical modeling is one of the key components to study coupled processes in in-situ combustion. We employed the thermo-hydraulic numerical simulator MUFITS (BINMIXT module) to address the influence of reactor pressure dynamics as well as hydro-geological coal and caprock parameters on water inflow and steam jacket dynamics. The US field trials Hanna and Hoe Creek (Wyoming) were applied for 3D model validation in terms of water inflow matching, whereby the good agreement between our modeling results and the field data indicates that our model reflects the hydrothermal physics of the process. In summary, our validated model allows a fast prediction of the steam jacket dynamics as well as water in- and outflows, required to avoid aquifer contamination during the entire life cycle of in-situ combustion operations.

  16. Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines

    Directory of Open Access Journals (Sweden)

    Wafa Tourab

    2016-06-01

    Conclusion: We project to set own national standards for exposure to electromagnetic fields, in order to achieve a regional database that will be at the disposal of partners concerned to ensure safety of people and mainly workers inside high voltage electrical substations.

  17. Radionuclide behavior at underground environment

    International Nuclear Information System (INIS)

    Hahn, Phil Soo; Park, Chung Kyun; Keum, Dong Kwon; Cho, Young Hwan; Kang, Moon Ja; Baik, Min Hoon; Hahn, Kyung Won; Park, Hyun Soo

    2003-04-01

    This study of radionuclide behavior at underground environment has been carried out as a part of the study of high-level waste disposal technology development. Therefore, the main objectives of this project are constructing a data-base and producing data for the safety assessment of a high-level radioactive waste, and verification of the objectivity of the assessment through characterization of the geochemical processes and experimental validation of the radionuclide migration. This project is composed of 6 subjects such as data production required for safety assessments, sorption properties and mechanisms, nuclide migration in the fractured rock, colloid formation and migration, nuclide speciation in deep geological environments, and total evaluation of geochemical behaviors considering multi-factors. The various results from the this project can be applicable to the preliminary safety and performance assessments of the established disposal concept for a future high-level radioactive waste repository. Providing required data and technical basis for assessment methodologies could be a direct application of the results. In a long-term view, the results can also be utilized as a technical background for the establishment of government policy for high-level radioactive waste disposal

  18. Advanced underground Vehicle Power and Control: The locomotive Research Platform

    Energy Technology Data Exchange (ETDEWEB)

    Vehicle Projects LLC

    2003-01-28

    Develop a fuelcell mine locomotive with metal-hydride hydrogen storage. Test the locomotive for fundamental limitations preventing successful commercialization of hydride fuelcells in underground mining. During Phase 1 of the DOE-EERE sponsored project, FPI and its partner SNL, completed work on the development of a 14.4 kW fuelcell power plant and metal-hydride energy storage. An existing battery-electric locomotive with similar power requirements, minus the battery module, was used as the base vehicle. In March 2001, Atlas Copco Wagner of Portland, OR, installed the fuelcell power plant into the base vehicle and initiated integration of the system into the vehicle. The entire vehicle returned to Sandia in May 2001 for further development and integration. Initial system power-up took place in December 2001. A revision to the original contract, Phase 2, at the request of DOE Golden Field Office, established Vehicle Projects LLC as the new prime contractor,. Phase 2 allowed industry partners to conduct surface tests, incorporate enhancements to the original design by SNL, perform an extensive risk and safety analysis, and test the fuelcell locomotive underground under representative production mine conditions. During the surface tests one of the fuelcell stacks exhibited reduced power output resulting in having to replace both fuelcell stacks. The new stacks were manufactured with new and improved technology resulting in an increase of the gross power output from 14.4 kW to 17 kW. Further work by CANMET and Hatch Associates, an engineering consulting firm specializing in safety analysis for the mining industry, both under subcontract to Vehicle Projects LLC, established minimum requirements for underground testing. CANMET upgraded the Programmable Logic Control (PLC) software used to monitor and control the fuelcell power plant, taking into account locomotive operator's needs. Battery Electric, a South Africa manufacturer, designed and manufactured (at no cost

  19. Underground Storage Tanks - Storage Tank Locations

    Data.gov (United States)

    NSGIC Education | GIS Inventory — A Storage Tank Location is a DEP primary facility type, and its sole sub-facility is the storage tank itself. Storage tanks are aboveground or underground, and are...

  20. State Certification of Underground Storage Tanks

    National Research Council Canada - National Science Library

    Granetto, Paul

    1998-01-01

    .... The audit was performed in response to a Senate Armed Services Committee inquiry about whether state environmental regulatory agencies would be able to certify that DoD underground storage tanks...

  1. EXPERIENCE IN RISK ASSESSMENT OF UNDERGROUND CONSTRUCTION

    Directory of Open Access Journals (Sweden)

    L. L. Kaufman

    2010-03-01

    Full Text Available The article gives examples of underground construction of hydropower station inNepaland sewer tunnel in the USA. These projects pay attention to influence of geotechnical risks and their consequences.

  2. Establishing sustainable strategies in urban underground engineering.

    Science.gov (United States)

    Curiel-Esparza, Jorge; Canto-Perello, Julian; Calvo, Maria A

    2004-07-01

    Growth of urban areas, the corresponding increased demand for utility services and the possibility of new types of utility systems are overcrowding near surface underground space with urban utilities. Available subsurface space will continue to diminish to the point where utilidors (utility tunnels) may become inevitable. Establishing future sustainable strategies in urban underground engineering consists of the ability to lessen the use of traditional trenching. There is an increasing interest in utility tunnels for urban areas as a sustainable technique to avoid congestion of the subsurface. One of the principal advantages of utility tunnels is the substantially lower environmental impact compared with common trenches. Implementing these underground facilities is retarded most by the initial cost and management procedures. The habitual procedure is to meet problems as they arise in current practice. The moral imperative of sustainable strategies fails to confront the economic and political conflicts of interest. Municipal engineers should act as a key enabler in urban underground sustainable development.

  3. Leaking Underground Storage Tank Sites in Iowa

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Leaking Underground Storage Tank (LUST) sites where petroleum contamination has been found. There may be more than one LUST site per UST site.

  4. Epinephrine, DNA integrity and oxidative stress in workers exposed to extremely low-frequency electromagnetic fields (ELF-EMFs) at 132 kV substations.

    Science.gov (United States)

    Tiwari, Ravindra; Lakshmi, N K; Bhargava, S C; Ahuja, Y R

    2015-03-01

    There is apprehension about widespread use of electrical and electromagnetic gadgets which are supposed to emit electromagnetic radiations. Reports are controversy. These electromagnetic fields (EMFs) have considerable effect on endocrine system of exposed subjects. This study was focused to assess the possible bioeffects of extremely low-frequency (ELF)-EMFs on epinephrine level, DNA damage and oxidative stress in subjects occupationally exposed to 132 kV high-voltage substations. The blood sample of 142 exposed subjects and 151 non-exposed individuals was analyzed. Plasma epinephrine was measured by enzyme-linked immunosorbent assay, DNA damage was studied by alkaline comet assay along with oxidative stress. Epinephrine levels of sub-groups showed mean concentration of 75.22  ±  1.46, 64.43  ±  8.26 and 48.47  ±  4.97 for high, medium and low exposed groups, respectively. DNA damage ranged between 1.69 µm and 9.91 µm. The oxidative stress levels showed significant increase. The individuals employed in the live-line procedures were found to be vulnerable for EM stress with altered epinephrine concentrations, DNA damage and increased oxidative stress.

  5. 30 CFR 57.8519 - Underground main fan controls.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground main fan controls. 57.8519 Section... Ventilation Surface and Underground § 57.8519 Underground main fan controls. All underground main fans shall have controls placed at a suitable protected location remote from the fan and preferably on the surface...

  6. Underground muons from Cygnus X-3

    International Nuclear Information System (INIS)

    Price, L.E.

    1985-01-01

    Underground detectors, intended for searches for nucleon decay and other rare processes, have recently begun searching for evidence of astrophysical sources, particularly Cygnus X-3, in the cosmic ray muons they record. Some evidence for signals from Cygnus X-3 has been reported. The underground observations are reported here in the context of previous (surface) observations of the source at high energies. 25 refs., 8 figs

  7. Heat Recovery Potential from Urban Underground Infrastructures

    OpenAIRE

    Davies, G; Boot-Handford, N; Grice, J; Dennis, W; Ajileye, A; Revesz, A; Maidment, GG

    2018-01-01

    This paper describes the results from a collaborative research project in the UK, focussing on the recovery of waste heat from underground railway tunnels, using London as a case study. The aim of the project was to investigate the feasibility of combining cooling of London’s underground railway tunnels with a waste heat recovery system. The recovered heat will then be transferred to a heat pump to upgrade its temperature, before delivery to a district heating network for reuse. The paper des...

  8. A comparison of magnetic fields inside and outside high-voltage urban 110-kV power substations with the exposure recommendations of the Ukrainian regulatory authorities.

    Science.gov (United States)

    Okun, Oleksandr; Shevchenko, Sergey; Korpinen, Leena

    2013-05-01

    The aim of this study was to carry out theoretical investigations of power frequency magnetic fields (MFs), produced inside and outside the domain of urban 110-kV power substations and to establish a correspondence between the levels of the fields and the specified population limits as defined by Ukrainian regulations. The fields produced by high-voltage substations were studied based on the application of the numerical finite element methodology. The investigations have shown that magnetic flux density values calculated inside and outside the considered 110-kV power substations do not reach the exposure limits specified by the Ukrainian regulations (1750 μT) and by international guidelines (ICNIRP 2010). Inside the domain of the substation, the maximum value of MFs was found under the 10-kV busbars and it equalled 420 μT.

  9. Underground ventilation remote monitoring and control system

    International Nuclear Information System (INIS)

    Strever, M.T.; Wallace, K.G. Jr.; McDaniel, K.H.

    1995-01-01

    This paper presents the design and installation of an underground ventilation remote monitoring and control system at the Waste Isolation Pilot Plant. This facility is designed to demonstrate safe underground disposal of U.S. defense generated transuranic nuclear waste. To improve the operability of the ventilation system, an underground remote monitoring and control system was designed and installed. The system consists of 15 air velocity sensors and 8 differential pressure sensors strategically located throughout the underground facility providing real-time data regarding the status of the ventilation system. In addition, a control system was installed on the main underground air regulators. The regulator control system gives indication of the regulator position and can be controlled either locally or remotely. The sensor output is displayed locally and at a central surface location through the site-wide Central Monitoring System (CMS). The CMS operator can review all sensor data and can remotely operate the main underground regulators. Furthermore, the Virtual Address Extension (VAX) network allows the ventilation engineer to retrieve real-time ventilation data on his personal computer located in his workstation. This paper describes the types of sensors selected, the installation of the instrumentation, and the initial operation of the remote monitoring system

  10. Groundwater and underground coal gasification in Alberta

    International Nuclear Information System (INIS)

    Haluszka, A.; MacMillan, G.; Maev, S.

    2010-01-01

    Underground coal gasification has potential in Alberta. This presentation provided background information on underground coal gasification and discussed groundwater and the Laurus Energy demonstration project. A multi-disciplined approach to project assessment was described with particular reference to geologic and hydrogeologic setting; geologic mapping; and a hydrogeologic numerical model. Underground coal gasification involves the conversion of coal into synthesis gas or syngas. It can be applied to mined coal at the surface or applied to non-mined coal seams using injection and production wells. Underground coal gasification can effect groundwater as the rate of water influx into the coal seams influences the quality and composition of the syngas. Byproducts created include heat as well as water with dissolved concentrations of ammonia, phenols, salts, polyaromatic hydrocarbons, and liquid organic products from the pyrolysis of coal. A process overview of underground coal gasification was also illustrated. It was concluded that underground coal gasification has the potential in Alberta and risks to groundwater could be minimized by a properly designed project. refs., figs.

  11. A distributed substation automation model based on the multi-agents technology; Um modelo distribuido de automacao de subestacoes baseado em tecnologia multiagentes

    Energy Technology Data Exchange (ETDEWEB)

    Geus, Klaus de; Milsztajn, Flavio; Kolb, Carlos Jose Johann; Dometerco, Jose Henrique; Souza, Alexandre Mendonca de; Braga, Ciro de Carvalho; Parolin, Emerson Luis; Frisch, Arlenio Carneiro; Fortunato Junior, Luiz Kiss; Erzinger Junior, Augusto; Jonack, Marco Antonio; Guiera, Anderson Juliano Azambuja [Companhia Paranaense de Energia (COPEL), Curitiba, PR (Brazil)]. E-mail: klaus@copel.com; flaviomil@copel.com; kolb@copel.com; dometerc@copel.com; alexandre.mendonca@copel.com; ciro@copel.com; parolin@copel.com; arlenio@copel.com; luiz.kiss@copel.com; aerzinger@copel.com; jonack@copel.com; guiera@copel.com

    2006-10-15

    The main purpose of this paper is to analyse distributed computing technology which can be used in substation automation systems. Based on performance comparative results obtained in laboratory, a specific model for distributed substation automation is proposed considering the current model employed at COPEL - Companhia Paranaense de Energia. The proposed model is based on the multi-agents technology, which has lately received special attention in the development of distributed systems with local intelligence. (author)

  12. Integrated digital system application to automation and control of distribution substations; Aplicacao de sistemas digitais comunicantes na automatizacao e controlo de subestacoes da distribuicao

    Energy Technology Data Exchange (ETDEWEB)

    Blanquet, Aurelio; Lopes, C. Pecas; Rego, Rui [Electricidade do Norte S.A. (EN), Porto (Portugal)

    1999-07-01

    This paper describes the application of integrated digital systems for automation and control of distribution substations. The evolution of the information technologies, particularly the data communication network and the using of digital technologies, allowed the specification of a solution based on a distributed structure which implements in a feasible safe and coherent way the function decentralization by the substations. Therefore, the process command an control system are approximate of the power equipment.

  13. Control and supervision integrated systems in power plants and substations: a standard and economical proposal at best portability and expansibility; Sistemas integrados de supervisao e controle em usinas e subestacoes: uma proposta economica e padronizada com maxima portabilidade e expansibilidade

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Adilio Ricardo Moreira de; Silva, Carlos Alberto Alves de Oliveira e; Freitas, Cesar Augusto Boavista de; Justo, Fernando Passos; Cotrim, Sergio Portela Romano; Neder, Ronaldo Nahar [FURNAS Centrais Eletricas S.A., Rio de Janeiro, RJ (Brazil)

    1995-12-31

    The aim of this work is to show that, based on the technical capability of the Brazilian electric sector companies on the process control using digital technology, it is possible to converge to a standard and economical solution at best portability and expansibility for the control and supervision integrated system of power plants and substations. Among the decisions to be taken by those companies, the authors emphasize the one which refers to the acquisition or development of such systems as well as the intended digitalization level. For the authors, it is advantageous that such development is limited to the specific applicatives necessary to the systems operation and will be as advantageous as the quantity of standard software and hardware that may become to be used with no prejudice to performance 3 refs.

  14. 30 CFR 57.12011 - High-potential electrical conductors.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-potential electrical conductors. 57.12011... Electricity Surface and Underground § 57.12011 High-potential electrical conductors. High-potential electrical conductors shall be covered, insulated, or placed to prevent contact with low potential conductors. ...

  15. 30 CFR 75.520 - Electric equipment; switches.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric equipment; switches. 75.520 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.520 Electric equipment; switches. All electric equipment shall be provided with switches or other controls that are...

  16. A Study on Effect of Concrete Foundations on Resistance and Surface Potentials of Gas Insulated Substation Grounding Systems

    Science.gov (United States)

    Rao, Mandava Mohana

    2017-10-01

    Ground resistance of high voltage substations must be as low as possible for safe grounding of their equipment both during normal and fault conditions. However, in gas insulated substations (GIS), even though resistance is low, it does not ensure the step and touch potentials of the grounding system within permissible levels. In the present study, an analytical model has been developed to calculate ground resistance, step and touch potentials of a grounding system used for GIS. Different models have been proposed for the evaluation of number of grounding rods to be inserted in to the ground. The effect of concrete foundations on above performance parameters has been analyzed by considering various fault currents, soil/earth resistivities and number of grounding rods. Finally, design optimization of GIS grounding system has been reported for fault currents in the order of 63 kA located in earth resistivity of 100Ω-m and above.

  17. The Underground Laboratory in South Korea : facilities and experiments

    Science.gov (United States)

    Kim, Yeongduk

    2017-01-01

    We have developed underground physics programs for last 15 years in South Korea. The scientific and technical motivation for this initiative was the lack of local facility of a large accelerator in Korea. Thanks to the large underground electric power generator in Yangyang area, we could construct a deep underground laboratory (Yangyang Laboratory, Y2L) and has performed some pioneering experiments for dark matter search and double beta decay experiments. Since year of 2013, a new research center in the Institute for Basic Science (IBS), Center for Underground Physics (CUP), is approved by the government and Y2L laboratory is managed by CUP. Due to the limited space in Y2L, we are proposing to construct a new deep underground laboratory where we can host larger scale experiments of next generation. The site is in an active iron mine, and will be made in 1100 meter underground with a space of about 2000 m2 by the end of 2019. I will describe the status and future plan for this underground laboratory. CUP has two main experimental programs. (1) Identification of dark matter : The annual modulation signal of DAMA/LIBRA experiment has been contradictory to many other experiments such as XENON100, LUX, and Super CDMS. Yale University and CUP (COSINE-100) experimentalists agreed to do an experiment together at the Y2L and recently commissioned a 100kg scale low background NaI(Tl) crystal experiment. In future, we will develop NaI(Tl) crystals with lower internal backgrounds and try to run identical detectors at both north and south hemisphere. Low mass WIMP search is also planned with a development of low temperature sensors coupled with highly scintillating crystals. (2) Neutrinoless double beta decay search : The mass of the lightest neutrino and the Majorana nature of the neutrinos are not determined yet. Neutrinoless double beta decay experiment can answer both of the questions directly, and ultra-low backgrounds and excellent energy resolution are critical to

  18. Digital Underground (Shh. It's really Applied Geophysics!)

    Science.gov (United States)

    McAdoo, B. G.

    2003-12-01

    Digital Underground (Geology/Physics 241) at Vassar College is an applied geophysics course designed for a liberal arts curriculum, and has nothing to do with Shock G and Tupac Shakur. Applied geophysics courses have a history of using geophysical methods on environmental contamination-type applications (underground storage tanks, leach fields, etc.). Inspired in large part by the Keck Geology Consortium project run by Franklin and Marshall College geophysicist (Robert Sternberg) and archaeologist (James Delle) in an old slave village in Jamaica in 1999, this class examines the history of slavery in New York's Hudson Valley region by way of its forgotten African-American graveyards. This multidisciplinary approach to an issue draws students from across the curriculum- we have had our compliments of geologists and physicists, along with students from sociology, environmental studies, history, and Africana studies. The name of the class and content are designed to attract a non-traditional student of geophysics.- The project-based nature of the class appeals to student yearning for an out-of-classroom experience. The uncontrolled nature of the class demonstrates the complications that occur in real-word situations. The class has in the past broken itself into two teams- a surveying team and an archival research team. Archival research is done (usually by the social scientists in the class) to add a human dimension to the geophysical. The surveying equipment used in delineating these forgotten graveyards includes a Total Station surveyor, an electrical resistivity meter, a magnetometer, and a ground penetrating radar. All students must have a rudimentary understanding of the physics behind the equipment (to the level of where they can explain it to the general public), and the methods used by those studying the archives. This is a project-based class, where the instructor acts as a project manager, and the students make the decisions regarding the survey itself. Every

  19. Relative Contribution of a Subsystem to the Environmental Impact of a Complex System: Application to Aluminium Electrolysis Conversion Substations

    OpenAIRE

    Cluzel , François; Millet , Dominique; Leroy , Yann; Yannou , Bernard

    2010-01-01

    International audience; We focus in this paper on the contribution of a subsystem to the environmental impact of a system. In this way we propose to explore some limits related to Life Cycle Assessment (LCA), in particular the consideration of the use phase specificities (for example lifetime, technology or energy mix). Two cases studies concerning AREVA T&D's aluminium electrolysis conversion substations are proposed to illustrate these problems. The first one considers the environmental con...

  20. 40 CFR 280.230 - Operating an underground storage tank or underground storage tank system.

    Science.gov (United States)

    2010-07-01

    ... underground storage tank or underground storage tank system. (a) Operating an UST or UST system prior to...) Operating an UST or UST system after foreclosure. The following provisions apply to a holder who, through..., the purchaser must decide whether to operate or close the UST or UST system in accordance with...

  1. Wireless system for explosion detection in underground structures

    Science.gov (United States)

    Chikhradze, M.; Bochorishvili, N.; Akhvlediani, I.; Kukhalashvili, D.; Kalichava, I.; Mataradze, E.

    2009-06-01

    Considering the growing threat of terrorist or accidental explosions in underground stations, underground highway and railway sections improvement of system for protecting people from explosions appears urgent. Current automatic protective devices with blast identification module and blast damping absorbers of various designs as their basic elements cannot be considered effective. Analysis revealed that low reliability of blast detection and delayed generation of start signal for the activation of an absorber are the major disadvantages of protective devices. Besides the transmission of trigger signal to an energy absorber through cable communication reduces the reliability of the operation of protective device due to a possible damage of electric wiring under blast or mechanical attack. This paper presents the outcomes of the studies conducted to select accurate criteria for blast identification and to design wireless system of activation of defensive device. The results of testing of blast detection methods (seismic, EMP, optical, on overpressure) showed that the proposed method, which implies constant monitoring of overpressure in terms of its reliability and response speed, best meets the requirements. Proposed wireless system for explosions identification and activation of protective device consists of transmitter and receiver modules. Transmitter module contains sensor and microprocessor equipped with blast identification software. Receiver module produces activation signal for operation of absorber. Tests were performed in the underground experimental base of Mining Institute. The time between the moment of receiving signal by the sensor and activation of absorber - 640 microsecond; distance between transmitter and receiver in direct tunnel - at least 150m; in tunnel with 900 bending - 50m. This research is sponsored by NATO's Public Diplomacy Division in the framework of "Science for Peace".

  2. Substation automation. Integration of applications of the SICLE; Automatizacion de subestaciones. Integracion de aplicaciones sobre el SICLE

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, Gustavo; Vega, Miguel [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    This paper presents the first applications developed by the Instituto de Investigaciones Electricas (IIE) on the infrastructure of the SICLE (Sistema de Informacion y Control Local de la Estacion) (Station Information and Local Control System), that Comision Federal de Electricidad (CFE) is now acquiring in order to automate its transmission substations. A computer infrastructure was obtained similar to the existing in the substation for the development of program testing at the IIE; the personnel of the same was trained; the applications in conjunction with the CFE specialists were defined; the agreed developments were made and installed at the Temascal II Substation. [Espanol] En el presente articulo se presentan las primeras aplicaciones desarrolladas por el Instituto de Investigaciones Electricas (IIE) sobre la infraestructura del SICLE (Sistema de Informacion y Control Local de Estacion) que esta adquiriendo la Comision Federal de Electricidad (CFE) a fin de automatizar sus subestaciones de transmision. Se obtuvo una infraestructura de computo similar a la existente en la subestacion para el desarrollo de prueba de programas en el IIE; se capacito al personal en la misma; se definieron las aplicaciones conjuntamente con los especialistas de la CFE; se hicieron los desarrollos acordados y se instalaron en la subestacion Temascal II.

  3. Holbrook Substation Superconductor Cable System, Long Island, New York Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Maguire, James; McNamara, Joseph

    2010-06-25

    The LIPA Superconductor project broke ground on July 4, 2006, was first energized on April 22, 2008 (Earth Day) and was commissioned on June 25, 2008. Since commissioning, up until early March, 2009, there were numerous refrigeration events that impacted steady state operations. This led to the review of the alarms that were being generated and a rewrite of the program logic in order to decrease the hypersensitivity surrounding these alarms. The high temperature superconductor (HTS) cable was energized on March 5, 2009 and ran uninterrupted until a human error during a refrigeration system switchover knocked the cable out of the grid in early February 2010. The HTS cable was in the grid uninterrupted from March 5, 2009 to February 4, 2010. Although there have been refrigeration events (propagated mainly by voltage sags/surges) during this period, the system was able to automatically switch over from the primary to the backup refrigeration system without issue as required during this period. On February 4, 2010, when switching from the backup over to the primary refrigeration system, two rather than one liquid nitrogen pumps were started inadvertently by a human error (communication) causing an overpressure in the cable cooling line. This in turn activated the pressure relief valve located in the grounding substation. The cable was automatically taken out of the grid without any damage to the components or system as a result of signals sent from the AMSC control cabinet to the LIPA substation. The cable was switched back into the grid again on March 16, 2010 without incident and has been operational since that time. Since switching from the backup to the primary is not an automatic process, a recent improvement was added to the refrigeration operating system to allow remote commands to return the system from backup to primary cooling. This improvement makes the switching procedure quicker since travel to the site to perform this operation is no longer necessary and

  4. Electrical energy in France in 2008

    International Nuclear Information System (INIS)

    2008-12-01

    The figures presented on this document account for the electricity flows recorded in Metropolitan France, including Corsica. Contents: national consumption; physical exchanges with foreign countries; electrical energy balance in France in 2008; net generation; noteworthy data for the year 2008 (daily maximum values of National consumption, Hydroelectric generation and non-Hydroelectric generation, Balance of physical exchanges); electricity market: cross-border contractual exchanges, balance responsible entities (Energy amount exchanged between balance responsible entities through the block exchange notifications), balancing mechanism (Global amount of energy activated upwards and downwards); power facilities: generating facilities in France (Nuclear, Fossil fuel thermal, Hydro-electric, Wind and Other renewable energy sources), transmission lines (circuit length in operation), transmission - transformers (installed capacity in operation); main transmission facilities commissioned during the year 2008 (substations connected to the RTE network and new or refurbished circuits)

  5. Particulate matter in the underground of Stockholm

    Science.gov (United States)

    Johansson, Christer; Johansson, Per-Åke

    The concentrations of PM 10 and PM 2.5 were measured during 2 weeks at an underground station in central Stockholm. The instrument, an automatic TEOM monitor (Tapered Element Oscillating Microbalance), was placed on the platform in the centre of the station. During weekdays between 7 a.m. and 7 p.m. the average PM 10 and PM 2.5 concentrations were 470 and 260 μg/ m3, respectively. These levels are a factor 5 and 10 times higher than the corresponding values measured in one of the busiest streets in central Stockholm. The concentrations in the underground followed closely the train traffic intensity. The levels were very similar from one day to the next. During Saturdays and Sundays the levels decreased slightly due to less frequent train passages. Additional measurements were performed right after the tunnel had been washed. Tunnel walls and railway tracks between the platforms of the underground system were washed using water. Only a slight reduction of the PM 10 levels (approximately 13%) could be observed during a few days after the water treatment. For PM 2.5 the reduction was even less, about 10% lower levels could be seen. This might indicate that particles from tunnel walls and tracks make only a minor contribution to the observed levels. These results confirm earlier unpublished measurements showing high levels of PM in the underground of Stockholm. Substantially, elevated particle exposure levels have also been reported in several earlier studies in the underground of London, UK.

  6. Technical measures and engineering management measures for radiation protection in underground uraniferous coal mine

    International Nuclear Information System (INIS)

    Wang Kaihua; Ding Dexin; Zhang Zhijun; Li Guangyue

    2006-01-01

    The reserves of uraniferous coal resource account for a certain proportion of all uranium resources in China. China began to mine the uraniferous coal deposits in late 1960s. In the process of mining, much research was conducted on the control and reduction of the radiation hazards in underground uraniferous coal mine. However, such mining practice was stopped for many reasons in late 1980s. During recent years, electricity shortages have taken place from time to time. In order to alleviate the shortages, the Chinese government has decided to further develop nuclear electricity. Under such circumstances, underground mining of uraniferous coal deposits will be restarted. In order to make sure that the radiation protection will be stressed and the radiation hazards will be controlled effectively in the underground uraniferous mine, this paper gives the basic knowledge of radiation protection, describes the radiation hazards to the miners and our national dosage standards implemented in the underground mine, and, on the basis of summing-up of the past experience in mine radiation protection, presents the technical and management measures for controlling and reducing radiation hazards. (authors)

  7. Simulation and study of power quality issues in a fixed speed wind farm substation.

    Science.gov (United States)

    Magesh, T; Chellamuthu, C

    2015-01-01

    Power quality issues associated with the fixed speed wind farm substation located at Coimbatore district are investigated as the wind generators are tripping frequently. The investigations are carried out using two power quality analyzers, Fluke 435 and Dranetz PX5.8, with one of them connected at group control breaker of the 110 kV feeder and the other at the selected 0.69 kV generator busbar during the period of maximum power generation. From the analysis of the recorded data it is found that sag, swell, and transients are the major events which are responsible for the tripping of the generators. In the present study, simulation models for wind, turbine, shaft, pitch mechanism, induction generator, and grid are developed using DIgSILENT. Using the turbine characteristics, a two-dimensional lookup table is designed to generate a reference pitch angle necessary to simulate the power curve of the passive stall controlled wind turbine. Various scenarios and their effects on the performance of the wind farm are studied and validated with the recorded data and waveforms. The simulation model will be useful for the designers for planning and development of the wind farm before implementation.

  8. Estimation of voltage unbalance at an AC traction substation with different train operational scenarios

    Directory of Open Access Journals (Sweden)

    Thanatchai Kulworawanichpong

    2017-07-01

    Full Text Available This paper presents the modeling and simulation of the voltage unbalance in the power supply system of an AC electrified railway. The operating voltage at the traction substation is obtained by MATLAB/SIMULINK program and the voltage unbalance is evaluated by considering the voltage unbalance factor (VUF. Suvarnabhumi Airport Rail Link (ARL, in Bangkok, Thailand, is chosen to be a case study. The ARL is supplied by two single-phase traction transformers connected as a cyclic permutation of phases. According to the extension plan of the ARL, four service scenarios with different headways, auxiliary loads and total weights of the trains were simulated to study how the different scenarios influence the VUF at the three-phase side. It can be summarized that at the same headway, the VUF was increased when the train weight and auxiliary power load were increased. In case of different headways, the longer the headway, the more voltage unbalance. The extension plan of the ARL in the near future can be achieved with the voltage unbalance level under the maximum allowable value.

  9. Development of expert system software to improve performance of high-voltage arresters in substations

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Andre Nunes de; Oltremari, Anderson; Zago, Maria Goretti; Silva, Paulo Sergio da; Costa Junior, Pedro da; Ferraz, Kleber [Sao Paulo State Univ. (UNESP), Bauru, SP (Brazil). Lab. of Power Systems and Intelligent Techniques], E-mail: andrejau@feb.unesp.br; Gusmao, Euripedes Silva; Prado, Jose Martins [ELETRONORTE, MT (Brazil)], E-mail: euripedes.gusmao@eln.gov.br

    2007-07-01

    One of the main causes of interruption and power outage on the energy distribution system in Brazil is related to lightning, which is also the main responsible by the reduction of service life and destruction of consumers and Utilities' equipment. As a manner of improving the protection of the energy distribution system, the Utilities have given attention on establishing maintenance techniques, such preventive as predictive, of the high-voltage arresters in substation. Currently, one of the main manners to obtain the installed arresters' characteristics involves the utilization of high cost equipment, such as leakage current meters. In this way, this paper aims to fulfill the needs of obtaining reliable results with the utilization of lower cost equipment, proposing a Expert System Software for diagnosing and aiding to decision through the utilization of intelligent techniques, which makes possible the monitoring of service life and the identification of aged arresters, allowing the establishment of one reliable chronogram for the removal of equipment, such for maintenance as for substitution. (author)

  10. Simulation and Study of Power Quality Issues in a Fixed Speed Wind Farm Substation

    Directory of Open Access Journals (Sweden)

    T. Magesh

    2015-01-01

    Full Text Available Power quality issues associated with the fixed speed wind farm substation located at Coimbatore district are investigated as the wind generators are tripping frequently. The investigations are carried out using two power quality analyzers, Fluke 435 and Dranetz PX5.8, with one of them connected at group control breaker of the 110 kV feeder and the other at the selected 0.69 kV generator busbar during the period of maximum power generation. From the analysis of the recorded data it is found that sag, swell, and transients are the major events which are responsible for the tripping of the generators. In the present study, simulation models for wind, turbine, shaft, pitch mechanism, induction generator, and grid are developed using DIgSILENT. Using the turbine characteristics, a two-dimensional lookup table is designed to generate a reference pitch angle necessary to simulate the power curve of the passive stall controlled wind turbine. Various scenarios and their effects on the performance of the wind farm are studied and validated with the recorded data and waveforms. The simulation model will be useful for the designers for planning and development of the wind farm before implementation.

  11. Bioremediation of Benzene-contaminated Underground Aquifers

    Science.gov (United States)

    Watanabe, Kazuya; Takahata, Yoh

    Contamination of underground aquifers with gasoline occurs frequently. Among the gasoline constituents, benzene is of great environmental concern, since it is carcinogenic, water-soluble and persistent under anaerobic conditions. We have analyzed a gasoline-contaminated underground aquifer undergoing natural attenuation, where benzene was degraded, albeit slowly, under anaerobic conditions. RNA-based stable-isotope probing identified that bacteria affiliated with the genus AZOARCUS was responsible for benzene degradation under nitrate-reducing conditions. This result was confirmed by isolating an anaerobic benzene-degrading bacterium AZOARCUS sp. strain DN11. This strain degraded benzene at relatively low concentrations (as low as 10 ppb). It could also degrade toluene and xylenes. In laboratory bioaugmentation experiments using benzene-contaminated groundwater, it was demonstrated that supplementation with DN11 significantly accelerated benzene degradation under a nitrate-reducing condition. These results indicate that DN11 is potentially useful for degrading benzene that contaminates underground aquifers at relatively low concentrations.

  12. Closures for underground nuclear power plants

    International Nuclear Information System (INIS)

    1981-10-01

    This study demonstrates that, with the appropriate selection of an access concept on the underground nuclear power plant, it is possible to design a gate complying with the increased requirements of the construction of an underground nuclear power plant. The investigations revealed that a comparison leakage of 42 mm in diameter for the failure of seals is too conservative. When selecting suitable seals a leakage being more extensive than the above mentioned one can be prevented even in case of disturbance lasting several months. The closure structures of the personnel and material accesses do not represent any weak point within the concept of the construction method for underground nuclear power plants. (orig./HP)

  13. Underground nuclear astrophysics at the Dresden Felsenkeller

    Energy Technology Data Exchange (ETDEWEB)

    Bemmerer, Daniel; Ilgner, Christoph; Junghans, Arnd R.; Mueller, Stefan; Rimarzig, Bernd; Schwengner, Ronald; Szuecs, Tamas; Wagner, Andreas [Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Dresden (Germany); Cowan, Thomas E.; Gohl, Stefan; Grieger, Marcel; Reinicke, Stefan; Roeder, Marko; Schmidt, Konrad; Stoeckel, Klaus; Takacs, Marcell P.; Wagner, Louis [Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Dresden (Germany); Technische Universitaet Dresden (Germany); Reinhardt, Tobias P.; Zuber, Kai [Technische Universitaet Dresden (Germany)

    2015-07-01

    Favored by the low background underground, accelerator-based experiments are an important tool to study nuclear astrophysics reactions involving stable charged particles. This technique has been used with great success at the 0.4 MV LUNA accelerator in the Gran Sasso laboratory in Italy. However, the nuclear reactions of helium and carbon burning and the neutron source reactions for the astrophysical s-process require higher beam energies, as well as the continuation of solar fusion studies. As a result, NuPECC strongly recommended the installation of one or more higher-energy underground accelerators. Such a project is underway in Dresden. A 5 MV Pelletron accelerator is currently being refurbished by installing an ion source on the high voltage terminal, enabling intensive helium beams. The preparation of the underground site is funded, and the civil engineering project is being updated. The science case, operational strategy and project status are reported.

  14. Underground pipe inspection device and method

    Energy Technology Data Exchange (ETDEWEB)

    Germata, Daniel Thomas [Wadsworth, IL

    2009-02-24

    A method and apparatus for inspecting the walls of an underground pipe from inside the pipe in which an inspection apparatus having a circular planar platform having a plurality of lever arms having one end pivotably attached to one side of the platform, having a pipe inspection device connected to an opposite end, and having a system for pivoting the lever arms is inserted into the underground pipe, with the inspection apparatus oriented with the planar platform disposed perpendicular to the pipe axis. The plurality of lever arms are pivoted toward the inside wall of the pipe, contacting the inside wall with each inspection device as the apparatus is conveyed along a length of the underground pipe.

  15. Master plan of Mizunami underground research laboratory

    International Nuclear Information System (INIS)

    1999-04-01

    In June 1994, the Atomic Energy Commission of Japan reformulated the Long-Term Programme for Research, Development and Utilisation of Nuclear Energy (LTP). The LTP (item 7, chapter 3) sets out the guidelines which apply to promoting scientific studies of the deep geological environment, with a view to providing a sound basis for research and development programmes for geological disposal projects. The Japan Nuclear Cycle Development Institute (JNC) has been conducting scientific studies of the deep geological environment as part of its Geoscientific Research Programme. The LTP also emphasised the importance of deep underground research facilities in the following terms: Deep underground research facilities play an important role in research relating to geological disposal. They allow the characteristics and features of the geological environment, which require to be considered in performance assessment of disposal systems, to be investigated in situ and the reliability of the models used for evaluating system performance to be developed and refined. They also provide opportunities for carrying out comprehensive research that will contribute to an improved overall understanding of Japan's deep geological environment. It is recommended that more than one facility should be constructed, considering the range of characteristics and features of Japan's geology and other relevant factors. It is important to plan underground research facilities on the basis of results obtained from research and development work already carried out, particularly the results of scientific studies of the deep geological environment. Such a plan for underground research facilities should be clearly separated from the development of an actual repository. JNC's Mizunami underground research laboratory (MIU) Project will be a deep underground research facility as foreseen by the above provisions of the LTP. (author)

  16. Effect of sags and shorts at electric network interruptions in cogeneration industrial plants; Efecto de los huecos de tension en plantas industriales con cogeneraciones

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Cander, J.; Bonfil, C. [Iberdrola (Spain); Fuster, V.; Catalan, S.

    1995-08-01

    At he moment the number of cogeneration facilities in the east region of Spain is rapidly increasing. The results concerning the behaviour and the problems that appear with sags and short at electric network interruptions are studied. It concludes the need of the substation protection system reconsideration to avoid the negative effects produced. 4 refs.

  17. Measurements of electric and magnetic fields, in heavy vehicles parking space, in the vicinity of a power station with 150kv to 20kv transformers

    Science.gov (United States)

    Gkanatsios, Stavros; Grigorescu, S.; Pliatsios, A.; Gkanatsiou, M.; Panagiotou, E.; Boukouvala, E.; Gavros, K.; Mitropoulos, D.

    2016-11-01

    The present paper investigates the electric and magnetic fields of extremely low frequencies in substations which step down voltage in Kozani, which is a city of about 65.000 inhabitants. In the substation, apart from the presence of voltage distribution transformers there are also power cables of 150 kV generated in pillars as well as power cables of 20 kV and 380V for the power supply of the city. Pillars with high, medium and low voltage power cables cross the parking space of heavy vehicles.

  18. Underground Nuclear Astrophysics Experiment JUNA in China

    Science.gov (United States)

    Liu, W. P.

    Underground Nuclear Astrophysics Experiment in China (JUNA) will take the advantage of the ultra-low background in Jinping underground lab. A 400 kV high current accelerator with an ECR source and γ , neutron and charged particle detectors will be set up. We plan to study directly a number of nuclear reactions important to hydrostatic stellar evolution near their Gamow window energies such as 25Mg(p, γ )26Al, 19F(p, α )16O, 13C(α , n)16O, and 12C(α , γ )16O, by the end of 2019.

  19. Analysis and design of SSC underground structures

    International Nuclear Information System (INIS)

    Clark, G.T.

    1993-01-01

    This paper describes the analysis and design of underground structures for the Superconducting Super Collider (SSC) Project. A brief overview of the SSC Project and the types of underground structures are presented. Engineering properties and non-linear behavior of the geologic materials are reviewed. The three-dimensional sequential finite element rock-structure interaction analysis techniques developed by the author are presented and discussed. Several examples of how the method works, specific advantages, and constraints are presented. Finally, the structural designs that resulted from the sequential interaction analysis are presented

  20. Assessment of condition of underground collector lines situated inside the technological complexes of underground storage facilities

    Directory of Open Access Journals (Sweden)

    Anton Misany

    2006-10-01

    Full Text Available The evaluation of status of underground gas pipeline systems operating for several decades becomes a decisive factor of the decision making for their further safe and reliable operation. The decision becomes crucial especially in cases when piping is installed within a facility without the cathodic protection. The evaluation and inspection of underground gas manifolds requires a specific approach tailored for the respective manifolds.In 2003 NAFTA, the company initiated an extensive plan of the underground gas manifolds diagnostics and evaluation. The results were presented within the Working Committee WOC2 at the 23rd World Gas Congress in Amsterdam.

  1. Ventilation experiment in the Mont Terri underground laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Mayor, J.C. [Empresa Nacional de Residuos Radiactivos, SA (ENRESA), Madrid (Spain); Velasco, M. [Dm-Iberia, Consultores en ciencias de la tierra, Madrid (Spain); Garcia-Sineriz, J.L. [Aitemin, Madrid (Spain)

    2005-07-01

    The required ventilation of the underground drifts during the construction and operational phases of a radioactive waste repository could give rise to a process of desaturation of the rock around the drifts, changing its hydraulic and thermal properties. This change of rock properties may have an impact on the design of the repositories (drifts spacing and repository size), which depends on the thermal load that the clay barrier and the rock can accept. The Ventilation Experiment (VE) has been carried out at the Mont Terri underground laboratory (Switzerland), and has been co-financed by the EC under contract FIKW-CT-2001-00126. Its main objective was to evaluate in-situ and better understand the desaturation process of a consolidated clay formation, when subjected to a flow of dry air during several months. This VE test has been performed under practically isothermal conditions (T {approx_equal} 15-16 C), in a 10 m long section of a non-lined horizontal micro-tunnel (diameter = 1,3 m), excavated in 1999 in the shaly facies of the Opalinus clay of Mont Terri. In the summer of year 2002 (3,4 years after the micro-tunnel excavation), the test section was sealed off by means of two double doors, and monitored with a total of 96 sensors (rock water potential, water content, temperature and displacements, and conditions of the air in the test section). Specifically, in a rock thickness of approximately two meters, 24 piezometers, 32 hygrometers, 10 TDR, 8 extensometers and 5 electrodes chains (geo-electrical survey) were installed. Hydraulic, geochemical and geo-electrical laboratory tests have been also performed to characterize the Opalinus clay properties. Besides, the in-situ VE test has been interpreted and modelled, using the obtained experimental data for calibration of several codes, such as the Code-Bright, Code-Aster, Tough 2 and Mherlin. (authors)

  2. Discovery Mondays - The particle physicist's best friend: electricity

    CERN Document Server

    2005-01-01

    One of CERN's electrical substations, at Prévessin. Electricity is one of CERN's closest allies. Without it, none of the physicists' extraordinary instruments would work. It is electricity that will guide and accelerate particles around the 27-km ring of the world's most powerful accelerator, the LHC. In the giant magnets inside the experiments electricity is also used to produce a magnetic field 200,000 times greater than the Earth's own magnetic field. Inside the detectors, the resulting magnetic force is used to bend the trajectories of the particles, allowing them to be identified and helping us gain a better understanding of what has happened at the heart of the collisions. Understanding how magnetic fields are produced inside the ATLAS experiment is one of several themes on the programme of the next Discovery Monday. And for a close-up view of operations, we'll also be taking you on a visit to the electricity substation at Meyrin. Come and meet CERN's best friend - electricity. Join us at the Micro...

  3. Physics at the proposed National Underground Science Facility

    International Nuclear Information System (INIS)

    Nieto, M.M.

    1983-01-01

    The scientific, technical, and financial reasons for building a National Underground Science Facility are discussed. After reviewing examples of other underground facilities, we focus on the Los Alamos proposal and the national for its choice of site

  4. Energy Policy Act of 2005 and Underground Storage Tanks (USTs)

    Science.gov (United States)

    The Energy Policy Act of 2005 significantly affected federal and state underground storage tank programs, required major changes to the programs, and is aimed at reducing underground storage tank releases to our environment.

  5. Underground siting of nuclear power plants

    International Nuclear Information System (INIS)

    Pinto, S.; Telleschi, P.

    1978-10-01

    Two of the main underground siting alternatives, the rock cavity plant and the pit siting, have been investigated in detail and two layouts, developed for specific sites, have been proposed. The influence of this type of siting on normal operating conditions and during abnormal occurences have been investigated. (Auth.)

  6. Zen Communist: Breyten Breytenbach's view from underground ...

    African Journals Online (AJOL)

    In an interview after his release from prison, Breyten Breytenbach describes himself, at the time he became involved in underground politics, as a Zen Communist. He returns occasionally to this interaction of Marxist ideas of social revolution and Buddhist ideas of non-attachment, but never attempts to explain the resulting ...

  7. Animals Underground. Young Discovery Library Series.

    Science.gov (United States)

    Ruffault, Charlotte

    This book is written for children ages 5 through 10. Part of a series designed to develop their curiosity, fascinate them and educate them, this volume explores the natural history of animals that live underground. Animals included are porcupine, insects, earthworm, mole, badger, rabbit, prairie dog, and beach animals. (YP)

  8. Nõukogudemaa underground bootleg'id / Margus Paju

    Index Scriptorium Estoniae

    Paju, Margus

    2008-01-01

    DVDst "Päratrusti pärand" - ENSV Riikliku Kultuurijäätmete Töötlemise Artelli "Päratrust" kultusfilmide kogumikust. Mustvalged underground-lühimängufilmid "Tsarli läheb Tallinna", "Tsaar Muhha", "Neurootiline pärastlõuna", "Kalkar", "Päratee" jt. aastatest 1980 -1983, filmid on taashelindatud 2007. aastal

  9. Underground siting of nuclear power plants

    International Nuclear Information System (INIS)

    Bender, F.

    1982-01-01

    The symposium gave the opportunity for an international exchange of views on the concepts of underground nuclear power plants, which are presently world wide under consideration. The results of investigations into the advantages and disadvantages with regard to the technical safety aspects of the underground plants in comparison to plants on the surface led to open and sometimes controversal discussions. As a result of the symposium (32 contributions) a general agreement can be stated on the judgement concerning the advantages and the disadvantages of underground nuclear power plants (nnp). The advantages are: increased protection against external events; delayed release of fission products in accident situations, if the closures operate properly. The disadvantages are: increased costs of the construction of underground and restrictions to such sites where either large caverns or deep pits can be constructed, which also requires that certain technical problems must be solved beforehand. Also, additional safety certificates related to the site will be required within the licensing procedures. The importance of these advantages and disadvantages was in some cases assessed very differently. The discussions also showed, that there are a number of topics where some questions have not been finally answered yet. (orig./HP) [de

  10. Underground application of magnetic resonance soundings

    CSIR Research Space (South Africa)

    Greben, JM

    2011-10-01

    Full Text Available that characterize the orientation of the mine wall. There is a geometric enhancement of the MRS signal under typical mining conditions for the locations studied. However, the loop size is severely restricted in underground conditions, limiting the feasible target...

  11. Underground mining robot: a CSIR project

    CSIR Research Space (South Africa)

    Green, JJ

    2012-11-01

    Full Text Available ) is the project lead unit and is developing the sensors needed for underground data acquisition related to the safety application. The body of the robot is being developed by the Mechatronics and Micro-Manufacturing (MMM) group. The software component is being...

  12. Modeling of long High Voltage AC Underground

    DEFF Research Database (Denmark)

    Gudmundsdottir, Unnur Stella; Bak, Claus Leth; Wiechowski, W. T.

    2010-01-01

    This paper presents the work and findings of a PhD project focused on accurate high frequency modelling of long High Voltage AC Underground cables. The project is cooperation between Aalborg University and Energinet.dk. The objective of the project is to investigate the accuracy of most up to dat...

  13. EAS selection in the EMMA underground array

    DEFF Research Database (Denmark)

    Sarkamo, J.; Bezrukov, L.; Enqvist, T.

    2013-01-01

    The first measurements of the Experiment with MultiMuon Array (EMMA) have been analyzed for the selection of the Extensive Air Showers (EAS). Test data were recorded with an underground muon tracking station and a satellite station separated laterally by 10 metres. Events with tracks distributed...

  14. Bioclimatic underground architecture: Development and principles

    OpenAIRE

    Stojić Jasmina; Stanković Danica

    2009-01-01

    The principal idea of paper lies in analyzing contemporary architectural challenges, concerning climate changes, global warming, renewable energy deficiency and population growth. The relevant examples and principles of sustainable and selfsustainable architecture development throughout history are presented. Underground structures as passive solar systems, vegetation used as insulation, ventilation and isolation are given as one of possible solutions for this global phenomenon. By studying t...

  15. Network reconfiguration for loss reduction in electrical distribution system using genetic algorithm

    International Nuclear Information System (INIS)

    Adail, A.S.A.A.

    2012-01-01

    Distribution system is a critical links between the utility and the nuclear installation. During feeding electricity to that installation there are power losses. The quality of the network depends on the reduction of these losses. Distribution system which feeds the nuclear installation must have a higher quality power. For example, in Inshas site, electrical power is supplied to it from two incoming feeders (one from new abu-zabal substation and the other from old abu-zabal substation). Each feeder is designed to carry the full load, while the operator preferred to connect with a new abu-zabal substation, which has a good power quality. Bad power quality affects directly the nuclear reactor and has a negative impact on the installed sensitive equipment's of the operation. The thesis is Studying the electrical losses in a distribution system (causes and effected factors), feeder reconfiguration methods, and applying of genetic algorithm in an electric distribution power system. In the end, this study proposes an optimization technique based on genetic algorithms for distribution network reconfiguration to reduce the network losses to minimum. The proposed method is applied to IEEE test network; that contain 3 feeders and 16 nodes. The technique is applied through two groups, distribution have general loads, and nuclear loads. In the groups the technique applied to seven cases at normal operation state, system fault condition as well as different loads conditions. Simulated results are drawn to show the accuracy of the technique.

  16. Analysis of world experience in constructing underground small nuclear power plants and assessment of its potential use in the Russian Arctic regions

    Directory of Open Access Journals (Sweden)

    Smirnov Yu. G.

    2016-03-01

    Full Text Available The paper considers the common ideology and main idea of locating underground nuclear plants. Specific examples in domestic and foreign experience have been analyzed. It has been established that underground small nuclear power plants can be used as an alternative source of electric and thermal energy for solving defense-strategic and social-economic tasks particularly when developing mineral raw material resources in the Russian Arctic regions

  17. Organ nic pollutants in underground water

    International Nuclear Information System (INIS)

    Hussein, H. H.

    1998-01-01

    Many organic compounds have been diagnosed in underground and surface waters, and there are many theories that explain the source of the dangerous materials on Punic health. The source of pollution could be the underground stored fuel or the polluted water in farms saturated with agricultural insecticides and chemical fertilizers, or there could be leaks in sewage water wastes. The source of pollution could also be the water surfaces in the areas of garbage disposal or industrial and home waste discharge. Due to the fact that the underground water is separated from oxygen in the air, its ability on self-purification is very low, in that the micro-organism that will do the dismantling and decomposition of the organic materials that pollute the water are in need for oxygen. In the event that underground water is subject to pollution m there are many methods for t resting the polluted water including the chemical decomposition method by injecting the polluted areas with neutralizing or oxidizing chemicals, such as Ozone, Chlorine or Hydrogen Peroxide. The mechanical methods could be used for getting rid of the volatile organic materials. As to biological decomposition, it is done with the use of bacteria in dismantling the poisonous materials into un poisonous materials. The preliminary analysis of water samples in one of the water wells in Sar ir and Tazarbo in Great Jamahirieh indicated that the concentration of total organic compounds (TOC) exceeded the internationally allowed limits. This indicates a deterioration of quality of some of underground water resources. It is well known that some of the organic pollutants have a great role in causing dangerous diseases, such as the polynuclear aromatic hydrocarbons and some halogenated compounds that cause cancer. Therefore, much research is required in this field for diagnosing the polluting organic compounds and determining the suitability of this water for drinking or for human consumption. (author). 21 refs., 6 figs

  18. Evaluation of the feasibility, economic impact, and effectiveness of underground nuclear power plants. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    1978-05-01

    Information on underground nuclear power plants is presented concerning underground nuclear power plant concepts; public health impacts; technical feasibility of underground concepts; economic impacts of underground construction; and evaluation of related issues.

  19. Evaluation of the feasibility, economic impact, and effectiveness of underground nuclear power plants. Final technical report

    International Nuclear Information System (INIS)

    1978-05-01

    Information on underground nuclear power plants is presented concerning underground nuclear power plant concepts; public health impacts; technical feasibility of underground concepts; economic impacts of underground construction; and evaluation of related issues

  20. Underground gasification and combustion brown with the use of groundwater

    Directory of Open Access Journals (Sweden)

    Zholudyev S.V.

    2011-11-01

    Full Text Available The problems of coal excavation and environement protection are priority for Ukraine. Underground coal gasification (UCG and underground coal incineration (UCI are combining excavation with simultaneous underground processing in entire technological process, capable to solve this problem. Using an intermediate heat carrier - ground water may optimisating of these processes.

  1. 30 CFR 57.4461 - Gasoline use restrictions underground.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Gasoline use restrictions underground. 57.4461... Prevention and Control Flammable and Combustible Liquids and Gases § 57.4461 Gasoline use restrictions underground. If gasoline is used underground to power internal combustion engines— (a) The mine shall be...

  2. Entrepreneurial Opportunity in Denmark’s Underground Economy

    DEFF Research Database (Denmark)

    Rezaei, Shahamak; Dana, L-P; Vang, Jan

    Based on interviews with immigrants to Denmark, meetings with stakeholders and with experts in the field, this article addresses issues regarding the underground economy in Denmark. What circumstances and factors characterise specific sectors or breaches to the ones in which undocumented immigrants...... participate in underground economic activities? Is the underground economy a pull factor for irregular/undocumented migration?...

  3. Underground Physics in Spain; La Fisica subterranea en Espana

    Energy Technology Data Exchange (ETDEWEB)

    Puimedon Santolaria, J.

    2005-07-01

    Underground laboratories provide the low background environment necessary to the search for extremely rare phenomena like neutrino oscillations, double deta decay or dark matter. There are only four underground infrastructures available in the Europe Union, one of them is in Spain: the Canfranc Underground Laboratory. (Author)

  4. 30 CFR 57.4360 - Underground alarm systems.

    Science.gov (United States)

    2010-07-01

    ... MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground alarm systems. 57.4360 Section 57...

  5. 78 FR 48591 - Refuge Alternatives for Underground Coal Mines

    Science.gov (United States)

    2013-08-08

    ... Administration 30 CFR Parts 7 and 75 Refuge Alternatives for Underground Coal Mines; Proposed Rules #0;#0;Federal... Underground Coal Mines AGENCY: Mine Safety and Health Administration, Labor. ACTION: Limited reopening of the... for miners to deploy and use refuge alternatives in underground coal mines. The U.S. Court of Appeals...

  6. 78 FR 73471 - Refuge Alternatives for Underground Coal Mines

    Science.gov (United States)

    2013-12-06

    ... Refuge Alternatives for Underground Coal Mines AGENCY: Mine Safety and Health Administration, Labor... Agency's Request for Information (RFI) on Refuge Alternatives for Underground Coal Mines. This extension...), MSHA published a Request for Information on Refuge Alternatives for Underground Coal Mines. The RFI...

  7. 78 FR 58264 - Refuge Alternatives for Underground Coal Mines

    Science.gov (United States)

    2013-09-23

    ... Refuge Alternatives for Underground Coal Mines AGENCY: Mine Safety and Health Administration, Labor... Agency's Request for Information (RFI) on Refuge Alternatives for Underground Coal Mines. This extension... Alternatives for Underground Coal Mines. The RFI comment period had been scheduled to close on October 7, 2013...

  8. 30 CFR 75.523 - Electric face equipment; deenergization.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric face equipment; deenergization. 75.523... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.523 Electric face equipment; deenergization. [Statutory Provision] An authorized representative of the...

  9. 30 CFR 57.12033 - Hand-held electric tools.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...

  10. 30 CFR 75.513-1 - Electric conductor; size.

    Science.gov (United States)

    2010-07-01

    ... capacity if it is smaller than is provided for in the National Electric Code, 1968. In addition, equipment... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric conductor; size. 75.513-1 Section 75... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.513-1...

  11. A Comparative Study on Substation Types and Network Layouts in Connection with Low-Energy District Heating Systems

    DEFF Research Database (Denmark)

    Tol, Hakan; Svendsen, Svend

    2012-01-01

    The study deals with low-energy district heating (DH) networks operating in low temperatures such as 55 °C in terms of supply and 25 °C in terms of return. The network layout, additional booster pumps, and different substation types such as storage tanks either equipped or not equipped in domestic...... hot water production site were examined. Effects of booster pumps on pipe dimensions in the latter case were investigated. Temperature drops during the summer months due to low heat demands of consumers were explored. Use of approaches such as looped networks and branched network layouts with bypasses...

  12. Functional utilization of control and digital protection systems in distribution substations; Aproveitamento funcional de sistemas de controle e protecao digitais em subestacoes de distribuicao

    Energy Technology Data Exchange (ETDEWEB)

    Brittes, Jose Luiz Pereira

    1996-07-01

    The application of Digital Protection and Control Systems (DPCS) in Utilities substations is a fundamental part for their Information System. Technological progress in Telematics provides nowadays, the implementation of open digital systems. But it is the wide exploitation of its potentiality that will be one of the survival factor in the competitive and multi-affair environment dictated by the new worldwide economical order. This exploitation is carried out in three levels inside the substation: at bay level, with inherent technological benefits, such as more efficient and reliable protection, data acquisition and registration, and smart control; at central level (substation), by the implantation of automatics with enormous operational and management profits; and a remote level, to whom DPCS's transpire like a very sophisticated large frame remote terminal units. (author)

  13. Measurement of the magnetic fields of high-voltage substations (230 kV) in Tehran (Iran) and comparison with the ACGIH threshold limit values.

    Science.gov (United States)

    Fard, Mahdieh Sharifi; Nasiri, Parvin; Monazzam, Mohammad Reza

    2011-06-01

    Measurements were made according to IEEE standard 644-1994 at a height of 1 m above floor level. It is concluded that none of the measurements exceeded the ACGIH threshold limit value. Among all control rooms the highest measured density amount is 0.69 μT in the control room of Ozgol substation and the lowest is 0.2 μT in the post of Shahid Firouzi. The control room of Ozgol substation is located in the second floor and bus-bars are located at a short distance from the window on the east, and so the highest recorded magnetic field is measured in this control room. Among all switchgear parts the highest amount 9.15 μT is measured in Kan substation. None of the measurements exceeded the ACGIH threshold limit value.

  14. The role of water in B-DNAs B I to B II conformer substates interconversion: a combined study by calorimetry, FT-IR spectroscopy and computer simulation

    Science.gov (United States)

    Pichler, Arthur; Rüdisser, Simon; Winger, Rudolf H.; Liedl, Klaus R.; Hallbrucker, Andreas; Mayer, Erwin

    2000-08-01

    Conformational substates of B-DNA had been observed so far in synthetic oligonucleotides but not in naturally occurring highly polymeric B-DNA. Our low-temperature experiments show that native B-DNA from salmon testes and the d(CGCGAATTCGCG) 2 dodecamer have the same B I and B II substates. Nonequilibrium distribution of conformer population was generated by quenching hydrated nonoriented films or fibers into the glassy state, and isothermal structural relaxation towards equilibrium by interconversion of substates was followed either by differential scanning calorimetry or by Fourier transform infrared spectroscopy. B I converts to B II on isothermal relaxation between 180 and 220 K, whereas on slow cooling from ambient temperature, B II converts to B I. State-of-the-art molecular dynamics simulation of the d(CGCGAATTCGCG) 2 dodecamer revealed that the B I→B II transition involves not only destacking of adjacent base pairs, but is coupled with migration of water from ionic phosphate to the sugar oxygen. These results are consistent with pronounced infrared spectral changes observed upon B I→B II interconversion. The B II substate is stabilized in comparison to B I by enhanced hydrogen-bond interaction with the migrating water. Curve resolution of infrared spectra showed that in hydrated nonoriented films of the d(CGCGAATTCGCG) 2 dodecamer, the B II population is enhanced in comparison to that in single crystals. Thus, the B II substate could be of biological relevance, and the B I to B II substate interconversion could be a major contributor to the protein recognition process.

  15. Energy optimization in an eco-district with electric vehicles smart charging

    OpenAIRE

    Dang , Xuan-Linh; Petit , Marc; Codani , Paul

    2015-01-01

    International audience; The energy modeling of an eco-district, composed of residential and commercial facilities, is proposed. First, an optimal strategy aiming at sizing the rated power of the substation transformer is introduced. Then, considering the introduction of photovoltaic (PV) panels and electric vehicles (EV) in the district, the new operating conditions of the transformer are detailed. In order to reduce (a) the peak power of the transformer and (b) the cumulative durations of th...

  16. Research into action of surface soil moistening, drying or freezing on electrical characteristics of grounding device

    Directory of Open Access Journals (Sweden)

    I.V. Nizhevskiy

    2014-03-01

    Full Text Available The analysis made has shown expediency of modernization rather than reconstruction of earth electrodes, after inspection of long operating substations grounding grids, via building a two-level structure. It will result in both technical and economic effects. The novelty of the results consists in studying, by means of a mathematical model, electrical characteristics of a two-level earth electrode versus the depth of surface soil drying or freezing.

  17. Technical and Economic Assessment of 6–10/0,4 kV Transformer Sub-Stations with Various Types of High-Voltage Switchgear

    Directory of Open Access Journals (Sweden)

    V. V. Stalovich

    2011-01-01

    Full Text Available The paper considers methodology for complex technical and economic assessment of 6-10/0,4 kV transformer sub-stations (TS. A database scheme has been developed and it makes it possible for synthesizing a computer program algorithm for selection of TS-type which has a switch-gear of an initial voltage. The paper presents results of technical and economic comparison of variants of two-transformer sub-stations with high-voltage switchgear on the basis of KCO-type chambers and with application of compact cells with sulfar hexafluorated insulation of КРУЭ type. 

  18. Measurement of age of underground water, using tritium

    International Nuclear Information System (INIS)

    Chatani, Kunio; Kagami, Tadaaki; Tomita, Ban-ichi; Onuma, Akiko; Shoka, Yasushi

    1978-01-01

    Age of four kinds of underground water in Aichi prefecture was estimated by measuring a concentration of tritium. The tritium concentration was measured by the usual method. The first water-bearing zone of the shallow part, about 50m in depth, of Nobi plain is a new underground water cultivated within 20 years, whereas second water-bearing zone is an old underground water of 20 years old or more. No relationship of water flow between the first and the second water-bearing zone was observed. A very deep underground about 100m or more in depth, of the Nobi plain is confirmed to be infinite years old fossil water by measuring of tritium. The underground water in Atsumi peninsula is mostly a new underground water within 20 years. Only one out of eight showed the existence of old underground water before 20 years or more. The underground water of the granite area at Mikawa district is confirmed to be old underground water before 20 years or more. Alkaline underground water in the granite zone is considered to be very old in view of composition of water. The origin of underground water can be learned by tritium concentration, which shows whether the water is new water in the neighborhood of earth's surface or very old cultivated water. (Iwakiri, K.)

  19. Leak detection for underground storage tanks

    International Nuclear Information System (INIS)

    Durgin, P.B.; Young, T.M.

    1993-01-01

    This symposium was held in New Orleans, Louisiana on January 29, 1992. The purpose of this conference was to provide a forum for exchange of state-of-the-art information on leak detection for underground storage tanks that leaked fuel. A widespread concern was protection of groundwater supplies from these leaking tanks. In some cases, the papers report on research that was conducted two or three years ago but has never been adequately directed to the underground storage tank leak-detection audience. In other cases, the papers report on the latest leak-detection research. The symposium was divided into four sessions that were entitled: Internal Monitoring; External Monitoring; Regulations and Standards; and Site and Risk Evaluation. Individual papers have been cataloged separately for inclusion in the appropriate data bases

  20. ANDES: An Underground Laboratory in South America

    Science.gov (United States)

    Dib, Claudio O.

    ANDES (Agua Negra Deep Experiment Site) is an underground laboratory, proposed to be built inside the Agua Negra road tunnel that will connect Chile (IV Region) with Argentina (San Juan Province) under the Andes Mountains. The Laboratory will be 1750 meters under the rock, becoming the 3rd deepest underground laboratory of this kind in the world, and the first in the Southern Hemisphere. ANDES will be an international Laboratory, managed by a Latin American consortium. The laboratory will host experiments in Particle and Astroparticle Physics, such as Neutrino and Dark Matter searches, Seismology, Geology, Geophysics and Biology. It will also be used for the development of low background instrumentation and related services. Here we present the general features of the proposed laboratory, the current status of the proposal and some of its opportunities for science.