WorldWideScience

Sample records for undergoing nai-131 capsules

  1. Additional effective dose by patients undergoing NAI-131 capsules therapy

    Energy Technology Data Exchange (ETDEWEB)

    Orlic, M.; Jovanovic, M.; Spasic Jokic, V.; Cuknic, O.; Ilic, Z.; Vranjes Djuric, S. [VINCA - Institute of Nuclear Sciences, Belgrade, Serbia and Montenegro (Yugoslavia)

    2006-07-01

    Capsules or solutions containing Na{sup 131}I are indicated for the therapy of some thyroid carcinomas such as functioning metastatic papillary or follicular carcinoma of the thyroid; and for the treatment of hyperthyroidism (diffuse toxic goiter and single or multiple toxic nodular goiter). The recommended dosage ranges of Na{sup 131}I capsules or solution for the therapy of the average patient (70 kg) are: (3.7-5.55) GBq for ablation of normal thyroid tissue; (3.7-7.4) GBq for subsequent treatments; a (148-370) MBq for hyperthyroidism. The purpose of this paper is to calculate effective dose as a result of iodine-131 capsules remaining in stomach before absorption starts. This result can determine the disadvantage of capsule versus solution containing sodium iodine-131 (Na{sup 131}I) in radionuclide therapy application from radiation protection point of view. The Monte Carlo code MCNP4b was used to model transport of gamma and beta particles emitted by radionuclide {sup 131}I treated as a point source at the bottom of stomach. Absorbed energy per unit transformation in stomach and surrounding organs has been calculated. (authors)

  2. ALARA implementation in 131I therapeutic capsule production facility

    International Nuclear Information System (INIS)

    Kumawat, Lalit; Swaminathan, N.; Sudheer, T.S.; Sachdev, S.S.; Arora, S.S.; Vairalkar, K.G.

    2005-01-01

    Sodium iodide 131 I solution had been invariably administered to patients for both diagnosis and therapy of thyrotoxicosis. The undue exposure to non-target organs has been over come by introducing NaI ( 131 I) in a gelatin capsule. BRIT has set up experimental facility for the preparation and the production volume has augmented into four fold due to increase in demand and the same facility is being used to cater the need. However, the adequately shielded facility (fume hood) used for (manual) dispensing activity in capsules, capsules and product vial capping, transfer of the vials into lead pots and activity measurement of each vial has resulted in significant increase in the personnel exposure. The sources had been identified and efforts were made to reduce the exposure in these operations. An annular shield was introduced around the dispenser, resulted in the reduction of radiation field at wrist level by a factor of three. Introduction of shielded automated dispenser and usage of longer tools for transfer and capping of vials has effected in two times reduction of collective wrist dose. Currently, the relocated capping station two meters away from the source certainly will bring down further exposure. (author)

  3. Sodium Iodide-131 (Na131I) AS Gelatin Capsules At TNRC-In Libya

    International Nuclear Information System (INIS)

    Sherief, M. F.; Abudeeb, F. N.; Abudaia, J. A.; Elghanoudy, Y. A.

    2004-01-01

    In this contribution, the production of a capsulated Na 131 I radiopharmaceutical, for treatment of variety of hyperthyroidism diseases, at Tajoura Nuclear Research Center in Tripoli-Libya is described. The process requires the application of a very small volume of iodine-131 (not more than 25μ l in some cases) with radioactivities reaching some 37 GBq per capsule. The application of such volume is necessary to prevent damage to gelatin material. Loading a volume of 100 μ l of radioactive Na 131 I solution containing 37 GBq. radioactivity within a capsule filled with anhydrous sodium hydrogen phosphate as an adsorption material for Na 131 I solution brings such solution into a direct interaction with the gelatin material. This is assumed to have an inadequate effect in therapy. To overcome this problem, the work team has introduced some substantial alterations on the irradiation procedure and the process of the pre-irradiation treatment of the target. As a consequence, that has successfully culminated in production of Na 131 I capsules with proper perspective (e.g. radioactive yield of 74 GBq from 37 GBq previously and radioactive concentration of 37 GBq/ml). (Authors)

  4. Therapeutic applications of radioactive 131iodine: Procedures and incidents with capsules

    International Nuclear Information System (INIS)

    Al Aamri, Marwa; Ravichandran, Ramamoorthy; Binukumar, John Pichy; Al Balushi, Naima

    2016-01-01

    Treatments for thyrotoxicosis and carcinoma thyroid are carried out by oral administration of radioactive iodine ( 131 I) in the form of liquid or capsules. The liquid form of 131 I has higher risk factors such as vapourization, spillage and need for management of higher activity wastes. Use of 131 I in capsule form simplify procedures of handling compared to liquid form of 131 I. The guidelines of safe handling and quality assurance aspects for therapeutic use 131 I are well outlined by International Atomic Energy Agency (IAEA) reports. A few unusual incidents with I-131 capsules encountered in the past need to be highlighted from health physics point of view. In Royal Hospital, Oman, I-131 is imported in capsules, and the total activity handled/year steadily increased over 10 years. Discrete activities range from 185 MBq (5 mCi) up to 7.4 GBq (200 mCi). In four incidents deviations in standard operational procedures were recorded. Nature of incidents is described as follows: (1) After assay of activity, the capsule was directly put in the lead container with missing of inner cap. (2) Patient poured water in the Perspex tube, when the capsule was handed over to her, making an emergency situation. (3) In 3 high activity capsules (2 nos 2.96 GBq, 1 no. 4.26 GBq), observed sticky behavior in capsule holder on the 2 nd day post receipt, which were in order on the 1 st day. (4) A capsule could not be swallowed by a patient, which was taken back from the mouth. Monitoring of patient later did not show residual ingested activity. The report documents some of the unusual incidents for information to other centers engaged in such radioactive administrations

  5. Production of 131I gelatin capsules

    International Nuclear Information System (INIS)

    Freud, A.; Hirshfeld, N.; Canfi, A.; Melamud, Y.

    1997-01-01

    Radioiodine ( 131 I) hard-gelatin capsules are widely used for the diagnosis and treatment of various thyroid disorders. Until 1980 radioiodine was supplied by us as a liquid dosage. This proved to be a rather inconvenient form since it resulted in inaccurate dosing by the physicians and caused frequent contamination of the patients and the hospital personnel. In an attempt to overcome these problems we have designed and constructed a production facility for capsules in which 1311 is packaged. Because of the extreme precautions necessary in handling radioactive compounds, encapsulation of radioactive materials requires specifically designed production techniques, special instrumentation and unique quality control procedures that are not encountered in the standard capsule production processes in the pharmaceutical industry

  6. Comparison of thyroid uptake of 131I capsule and solution in rabbits and graves disease patients

    International Nuclear Information System (INIS)

    Zhou Xinjian; Li Fang; Lu Jingqiao; Chen Daming; Zhang Ruilin

    2002-01-01

    Objective: To observe the difference between thyroid uptake rates (TUR) of 131 I capsule and solution in rabbits and Graves disease patients. Methods: Part one: 6 rabbits randomized into two groups received capsule or solution of 131 I 7.4 MBq. Then with SPECT scintigraphy 2,4,6 and 24 h thyroid pure counts in percentage of stomach counts (first frame) were determined. Part two: 1) Measured 131 I capsule standard. 2) 104 patients with Graves disease were administered tracing and therapeutic dose of 131 I capsule (capsule group), 118 of 131 I solution (solution group). Compared the tracing and therapeutic 131 I TUR at 24 h. Results: Part one: There were no significant difference at 2,4,6,24 h TUR between capsule and solution group. For 1 case the maximum TUR was at 6 h in capsule group and 2 cases in solution groups. Part two: 1) For the 131 I capsule administered immediately after being dissolved in 30 mL of water, the activity counts measured were higher by (13.8 +- 2.8)% than it was administered directly, t8.97, P 0.05) and in solution group were (71.3 +- 12.3)% and (65.1 +- 13.0)% (t = 3.82, P 131 I capsule standard should be dissolved before being measured. 3) 131 I capsules can be used as a standard formulation for Graves disease patients. 4) The dose of 131 I should be increased as tracer TUR is larger than 80.0%

  7. Why 131I liquid is better than capsule in thyroid CA patients evaluation of effect and side effect by quantification

    International Nuclear Information System (INIS)

    Prakash, Om; Tiwari, R.; Rach, S.; Patel, N.; Patel, V.; Vyas, R.K.

    2014-01-01

    The objective of this study was to compare the ablation rate and side effect with high dose radioiodine ( 131 I) capsule and liquid formulation. Capsule and liquid radioiodine ( 131 I) is routinely used in treatment of differentiated thyroid carcinoma. In thyroid tissue it accumulates 17-25 times more than the other parts of the body. It exert cyto toxic effect on thyroid tissue by beta emission. All the capsules and liquid radio iodine procured from BRIT, Bhabha Atomic Research Centre, Mumbai. All the patients fasted for at least 8 hrs or overnight before the dose and 1 hr after. More than 300 patients included in this study. Before large dose therapy all pts. Given 1-2 mCi 131 I and gamma imaging done with dual head gamma camera, high energy collimator used 150 pts. Got liquid iodine and 150 pts. Got capsule. The liquid form of 131 I absorbed from stomach within 15-30 min, but capsules dissolve slowly and shape maintained upto 2 hrs due to slow absorption rate mucosal lining of stomach get very high radiation dose from 100 mCi, the dose to stomach wall was approx 448 rad or 4.48 Gy per hour. On the other side liquid 131 I delivered very less dose to stomach. After admission of 131 I therapy pts. Were kept in isolation ward. Common complain from both type (liquid and capsule) was nausea, vomiting, neck pain and abdominal pain. So I have calculated the dose to stomach from capsule which was approx. 6-10 Gy to stomach. Due to radiation injury mucosa lining damage occurs, replacement of that mucosal lining takes place in 5-10 days. This quantification and dosimetric evaluation is pointing that liquid 131 I is better for patients. Quick absorption and less dose to abdomen. So less gastralgia complain (author)

  8. Production of 131I capsules. Quality control of the different stages from the physician's order to patient's administration

    International Nuclear Information System (INIS)

    Freud, A.

    2003-01-01

    The Radiochemistry Department of Rotem Industries produces 131 I hard gelatin capsules for the treatment and diagnosis of different thyroid disorders. Each capsule is designated for a specified patient according to the physician's decision that is based on the patient's morbid status. GMP (Good Manufacturing Practices) requirements have been implemented throughout the production process resulting in the accreditation by the Israeli Ministry of Health. A computerized system has been developed and is used as a QC tool throughout the process of 131 I capsule production. The request by the physician for capsules of various activities are introduced into the system and the process from production through packaging and external radiation monitoring is computer-controlled. The system prevents the possibility of double orders, out of specification production and enables documentation of data regardless of production date. (author)

  9. Iodine capsules in thyroid therapy: An individually controlled study of I-131 uptake kinetics as compared to liquid administration

    International Nuclear Information System (INIS)

    von Schulthess, G.K.; Seelentag, W.W.; Pfeiffer, G.; Blauenstein, P.; Bekier, A.

    1984-01-01

    The aim of this study was to determine the additional radiation dose sustained by parts of the patients gastric mucosa when given I-131 therapy in capsular rather than liquid form, and thus to establish the safety of this procedure. 16 patients with benign thyroid disease were studied by measuring serum radioactivity at 0, 5, 10, 20, 40, and 80 min. after administration of the capsule (120-200 MBq I131). These serum uptake values were compared to the uptake after administration of a liquid diagnostic dose of I-131 (2 MBq). From the resulting uptake curves the delay due to capsular dissolution was determined. The average dissolution time was found to be 12 min. with a large standard deviation of 7 min. Also, a theoretical curve was computed to indicate the dose rate as a function of the distance from the surface of the capsule. Based on this information the maximum dose to the gastric mucosa is of the order of 250 cGy for a therapeutic activity of 185 MBq, which is the maximum dose which may be given as single application to outpatients in Switzerland. By having the patient swallow some liquid during the first ten minutes, the capsule can be made to move around, and hence, the local radiation dose can be reduced substantially. The authors conclude, that I-131 in capsular form is a safe galenic form for therapeutic use in patients with thyroid disease. When large doses are given, administration of the dose in several capsules may be advisable

  10. Development of departmental standard for traceability of measured activity for 131I therapy capsules used in nuclear medicine

    International Nuclear Information System (INIS)

    Ravichandran, Ramamoorthy; Binukumar, J.P.

    2011-01-01

    International Basic Safety Standards (International Atomic Energy Agency, IAEA) provide guidance levels for diagnostic procedures in nuclear medicine indicating the maximum usual activity for various diagnostic tests in terms of activities of injected radioactive formulations. An accuracy of ± 10% in the activities of administered radio-pharmaceuticals is being recommended, for expected outcome in diagnostic and therapeutic nuclear medicine procedures. It is recommended that the long-term stability of isotope calibrators used in nuclear medicine is to be checked periodically for their performance using a long-lived check source, such as 137 Cs, of suitable activity. In view of the un-availability of such a radioactive source, we tried to develop methods to maintain traceability of these instruments, for certifying measured activities for human use. Two re-entrant chambers ((HDR 1000 and Selectron Source Dosimetry System (SSDS)) with 125 I and 192 Ir calibration factors in the Department of Radiotherapy were used to measure Iodine-131 ( 131 I) therapy capsules to establish traceability to Mark V isotope calibrator of the Department of Nuclear Medicine. Special nylon jigs were fabricated to keep 131 I capsule holder in position. Measured activities in all the chambers showed good agreement. The accuracy of SSDS chamber in measuring 192 Ir activities in the last 5 years was within 0.5%, validating its role as departmental standard for measuring activity. The above method is adopted because mean energies of 131 I and 192 Ir are comparable. (author)

  11. Gamma dose estimation to the gastric wall after administration of a capsule containing a large dose of /sup 131/I

    Energy Technology Data Exchange (ETDEWEB)

    Oyamada, H; Fukukita, H; Kawai, H; Nagaiwa, K [National Cancer Center, Tokyo (Japan); Kawachi, K

    1980-05-01

    Gamma dose to the gastric wall from a capsule containing 1.85 GBq (50 mCi) of /sup 131/I was estimated in 6 patients who had received total thyroidectomy for thyroid carcinoma some years before. The tests were done with a 37 MBq (1 mCi) capsule each in 5 patients and with a 185 MBq (5 mCi) capsule in one patient. All the patients were requested to fast in the morning. The capsule was given with a glass of water (200 ml). Then, the patient kept supine position under the scintillation camera for a period of one hour except one patient on whom the test was suspended at 30 minutes because of early clearance of the radioactivity from the stomach. In one of 5 patients who were tested for a period of one hour, serial scinticamera images showed almost no movement and minimum dissolution of the capsule. The remaining 4 patients showed slight to moderate movements of the capsules with a variety of dissolution speeds. Data processing were done by Scintipac-1200. The estimated doses at the distance of 0.5 cm from the source were 3.820, 2.074, 1.445, 1.154 and 1.462 grays (382.0, 207.4, 144.5, 115.4 and 146.2 rads) per initial one hour and 375 mGy (37.5 rad) per initial 30 minutes, respectively. From these data, it is thought to be wise to advise the patient to rotate or shake the body on bed occasionally after swallowing the capsules containing a large dose of /sup 131/I for the treatment of thyroid cancer. It is also desirable to recommend the patient to walk around even though the controlled patient's room is small. Additional water may be also meaningful to avoid unnecessary irradiation to the gastric wall.

  12. Small-bowel neoplasms in patients undergoing video capsule endoscopy

    DEFF Research Database (Denmark)

    Rondonotti, E; Pennazio, M; Toth, E

    2008-01-01

    BACKGROUND AND STUDY AIM: Small-bowel tumors account for 1% - 3% of all gastrointestinal neoplasms. Recent studies with video capsule endoscopy (VCE) suggest that the frequency of these tumors may be substantially higher than previously reported. The aim of the study was to evaluate the frequency......, clinical presentation, diagnostic/therapeutic work-up, and endoscopic appearance of small-bowel tumors in a large population of patients undergoing VCE. PATIENTS AND METHODS: Identification by a questionnaire of patients with VCE findings suggesting small-bowel tumors and histological confirmation...... of the neoplasm seen in 29 centers of 10 European Countries. RESULTS: Of 5129 patients undergoing VCE, 124 (2.4%) had small-bowel tumors (112 primary, 12 metastatic). Among these patients, indications for VCE were: obscure gastrointestinal bleeding (108 patients), abdominal pain (9), search for primary neoplasm...

  13. [Treatment of Graves Hyperthyroidism by Jiakangling Capsule Combined with Reduction of 131I: an Efficacy Observation].

    Science.gov (United States)

    Liu, Guan-xin; Liao, Ning

    2016-01-01

    To observe the clinical efficacy of Jiakangling Capsule (JC) combined with reduction of 1311 in treatment of Graves hyperthyroidism. Totally 387 Graves hyperthyroidism patients were randomly assigned to the treatment group (200 cases) and the control group (187 cases). Patients in the treatment group took JC combined with reduction of 131I. The 131I dosage per gram of thyroid tissue was 50-80 microCi. They additionally took JC one week after taking 1311 for one consecutive month. Patients in the control group took 131 routinely as one disposable treatment. The 131I dosage per gram of thyroid tissue was 70-120 microCi, without using JC or other anti-thyroid drugs. All patients were reexamined after 24-month treatment. Whether hyperthyroidism was cured, incurred, or permanent was observed. Efficacies of thyroglobulin antibody (TGAb) and thyroid microsome antibody (TMAb) were compared between the two groups. Compared with the control group, the incurred ratio increased in the treatment group [3.2% (6/187) vs. 16.0% (32/200), P hyperthyroidism induced permanent hypothyroidism than routine 1311 treatment, especially for strong positive TGAb and TMAb patients.

  14. Methodology for calibration of detector of NaI (TI)) 3 ' X 3 ' for in vivo measurements of patients with hyperthyroidism undergoing to radioiodotherapy

    International Nuclear Information System (INIS)

    Carvalho, Carlaine B.; Lacerda, Isabelle V.B.; Oliveira, Mercia L.; Hazin, Clovis A.; Lima, Fabiana F.

    2013-01-01

    The aim of this study is to establish the methodology for calibration of the detection system to be used in determining the therapeutic activity of 131 I required to release desired absorbed dose in the thyroid gland . This step is critical to the development of a protocol for individualized doses. The system consists of a detector of NaI (Tl ) 3'x3' coupled to software Genie 2000. We used the calibration sources of 60 Co , 137 Cs and 133 Ba. We obtained the straight calibration system, with sources 60 Co and 137 Cs. Subsequently , the detector was calibrated using a thyroid phantom-neck designed and produced by the IRD / CNEN with known activity of 133 Ba standard solution containing 18.7 kBq (on 09/24/12) evenly distributed. He was also calibrated with other thyroid- neck phantom model 3108 manufactured by Searle Radigraphics Ind., containing a liquid source of 131 I ( 7.7 MBq ). Five measurements were performed during 5 minutes for three different distances detector-simulator and calculated the corresponding calibration factors . The values of the calibration factors found for the simulator made by IRD and Searle Radigraphics Ind. for the distances 20, 25 and 30 cm were 0.35 , 0.24, 0.18, 0.15 , 0.11, 0, 09 , respectively. With the detection system properly calibrated and the calibration factors established, the technique is suitable for the evaluation of diagnostic activities of 131 I incorporated by hyperthyroid patients. (author)

  15. Calibration of filters for detection of airborne I-131 in the environment of nuclear power plant; Kalibracija filtrov za detekcijo I-131 v zraku okolja jedrske elektrarne

    Energy Technology Data Exchange (ETDEWEB)

    Zupan, M; Miklavzic, U; Pucelj, B [Institut Jozef Stefan, Ljubljana (Yugoslavia)

    1982-07-01

    A simple and clean method for efficiency calibration of filters for collection of airborne I and corresponding Ge(Li) spectrometer is described. As the calibrated source of gaseous I-131 the radiopharmaceutical water solution of NaI is used. As calibration example the absolute activity distribution of I-131 measured in a charcoal filter is shown. (author)

  16. Diagnostic and therapeutic radio pharmaceutical capsules

    International Nuclear Information System (INIS)

    Haney, T.A.; Wedeking, P.W.; Morcos, N.A.

    1981-01-01

    An improved pharmaceutical radioactive capsule consisting of a non-toxic, water soluble material adapted to being ingested and rapidly disintegrating on contact with fluids of the gastro-intestinal tract is described. Each capsule is provided with filler material supporting a pharmaceutically useful radioactive compound absorbable from the gastro-intestinal tract. The capsule is preferably of gelatin, methyl cellulose or polyvinyl alcohol and the filler is a polyethylene glycol. The radioactive compound may be iodine e.g. sodium radioiodide I-131 or 123. The capsule may also contain a reducing agent e.g. sodium thiosulphate, sulphite, or bisulphite. (author)

  17. Liquid discharges from patients undergoing {sup 131}I treatments

    Energy Technology Data Exchange (ETDEWEB)

    Barquero, R. [Servicio de Radiofisica y Proteccion Radiologica, Hospital Universitario Rio Hortega, E-47010 Valladolid (Spain)], E-mail: rbarquero@hurh.sacyl.es; Basurto, F. [Departamento de Fisica Teorica, Atomica y Optica, Universidad de Valladolid, E-47010 Valladolid (Spain); Nunez, C. [Servicio de Radiofisica y Proteccion Radiologica, Fundacion Jimenez Diaz, FJD, E-82001 Madrid (Spain); Esteban, R. [Servicio de Radiologia, Hospital Clinico Universitario, E-47005 Valladolid (Spain)

    2008-10-15

    This work discusses the production and management of liquid radioactive wastes as excretas from patients undergoing therapy procedures with {sup 131}I radiopharmaceuticals in Spain. The activity in the sewage has been estimated with and without waste radioactive decay tanks. Two common therapy procedures have been considered, the thyroid cancer (4.14 GBq administered per treatment), and the hyperthyroidism (414 MBq administered per treatment). The calculations were based on measurements of external exposure around the 244 hyperthyroidism patients and 23 thyroid cancer patients. The estimated direct activity discharged to the sewage for two thyroid carcinomas and three hyperthyroidisms was 14.57 GBq and 1.27 GBq, respectively, per week; the annual doses received by the most exposed individual (sewage worker) were 164 {mu}Sv and 13 {mu}Sv, respectively. General equations to calculate the activity as a function of the number of patient treated each week were also obtained.

  18. Radiation exposure to nuclear medicine technologists from administering I-131 therapy dosages

    International Nuclear Information System (INIS)

    Chaudakshetrin, P.; Pusuwan, P.; Sritongkul, N.; Tuntawiroon, M.

    2007-01-01

    Full text: Therapeutic doses of I-131 for treatment of thyroid cancer are administered orally in liquid or capsule form. During the last few years, a total number of patients loaded in our isolation ward increased from 4 to 10 patients per week. When considering radiation safety precautions for attending technologists, it is preferable to use the dose in capsules. The purpose of this study is to compare radiation exposure to nuclear medicine technologists from administering I-131 therapy dosages in capsules and in liquid form in a closed system. Materials and Methods: Three year radiation exposure to technologists during I-131 administration was analyzed. From January 2004 to June 2005 dose administration was in liquid form (n=263) and from July 2005 to February 2007 in capsules (n=541). Radiation dose assessment was performed with an electronic personal dosimeter (PDM 112). The dose rate in μSv and time spent per patient were recorded. Results: Dose received per patient when I-131 was given in a liquid was 3.50 ± 1.67 μSv and 1.17 ± 0.66 μSv when given in capsules. Compared with the use of a liquid, capsules significantly reduced radiation dose to technologists by 66% (P < 0.001). These doses received depended not only on the administered activity but also on the time, distance and shielding. Time spent per patient, including a brief visit before the time of dosing to explain the procedure and answer questions was reduced slightly from 4.4 ± 2.2 to 3.7 ± 1.8 minutes (P < 0.01). These correspond to a reduction in a yearly dose to 1 technologist by 40%, from 0.63 mSv to 0.38 mSv from dosing to 175 and 325 patients respectively. Conclusions: The measured doses clearly showed that handling of I-131 therapy dosages either in a liquid form or capsules are not the major contributors to the technologist's radiation exposure in routine clinical practice. However, one has to be cautious and follow good work practice to avoid risk of radiation exposure and radioiodine

  19. Development of a kinetic model and calculation of radiation dose estimates for sodium iodide-131I in athyroid individuals

    International Nuclear Information System (INIS)

    Rodriguez, M.

    1997-07-01

    The treatment for some thyroid carcinomas involves surgically removing the thyroid gland and administering the radiopharmaceutical Sodium iodide- 131 I (NaI). A diagnostic dose of NaI is given to the patient to determine if remnant tissue from the gland remains or larger doses are administered in order to treat the malignant tissue. Past research regarding NaI uptake and retention in euthyroid individuals (normal functioning thyroid) reveal that radioiodine concentrates mainly in the thyroid tissue and the remaining material is excreted from the body. The majority of radioiodine in athyroid (without thyroid) individuals is also eliminated from the body; however, there has been recent evidence of a long-term retention phase for individuals with no radioiodine concentrating tissue. The general purpose of this study was to develop a kinetic model and estimate the absorbed dose to athyroid individuals regarding the distribution and retention of NaI

  20. Fatty acids labelled with iodine 123 or 131 in. omega. position; myocardial evolution

    Energy Technology Data Exchange (ETDEWEB)

    Riche, F.; Vidal, M. (Grenoble-1 Univ., 38 (France)); Mathieu, J.P.; Busquet, G.; Comet, M. (Grenoble-1 Univ., 38 - La Tronche (France)); Coornaert, S.; Bardy, A. (CEA Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France). Office des Rayonnements Ionisants); Godart, J. (Grenoble-1 Univ., 38 (France). Inst. des Sciences Nucleaires)

    A simple and rapid method of labelling a number of saturated acetylenic and Z or E ethylenic acids has been developed. The fatty acids are labelled with /sup 123/I- or /sup 131/I- in the ..omega.. position by isotopic exchange labelled NaI in acetone. Myocardial metabolism was studied by injecting the labelled fatty acids into mice.

  1. Development of a kinetic model and calculation of radiation dose estimates for sodium iodide-{sup 131}I in athyroid individuals

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, M.

    1997-07-01

    The treatment for some thyroid carcinomas involves surgically removing the thyroid gland and administering the radiopharmaceutical Sodium iodide-{sup 131}I (NaI). A diagnostic dose of NaI is given to the patient to determine if remnant tissue from the gland remains or larger doses are administered in order to treat the malignant tissue. Past research regarding NaI uptake and retention in euthyroid individuals (normal functioning thyroid) reveal that radioiodine concentrates mainly in the thyroid tissue and the remaining material is excreted from the body. The majority of radioiodine in athyroid (without thyroid) individuals is also eliminated from the body; however, there has been recent evidence of a long-term retention phase for individuals with no radioiodine concentrating tissue. The general purpose of this study was to develop a kinetic model and estimate the absorbed dose to athyroid individuals regarding the distribution and retention of NaI.

  2. Synthesis labeling and biological studies of 16-131I

    International Nuclear Information System (INIS)

    Sato, M.K.

    1988-01-01

    The increasing interest in obtaining radiopharmaceuticals for metabolic imaging of heart muscle led us to prepare 16-IODINE HEXADECANOIC ACID by tosilation of the corresponding hydroxy acid, following iodination with NaI and finally, introducing radioiodine (Na 131 I) by isotopic exchange reaction. The reaction products were identified by determination of melting point, elementary and spectroscopic analysis such as infra-red absortion and magnetic nuclear resonance. The radiopharmaceutical after radiochemical and other specific control procedures for injetable such as sterility and apyrogenicity, was firstly utilized in dogs: preferencial uptake by the heart, as well as by the liver was confirmed. Then, studies in patients with or without heart diseases were performed. The biodistribution of 16- 131 I-HEXADECANOIC ACID was carried out in Wistar rats. The scintigraphic images in animals and in humans demonstrated that 16- 131 -HEXADECANOIC ACID is suitable for studying viable areas as well as energetic exchange of heart muscle. (author) [pt

  3. 131I treatment in patients undergoing renal dialysis: our experience

    International Nuclear Information System (INIS)

    Tobarra, Bonifacio; Campos, Pedro A.; Gonzalez Lopez, Antonio; Palma, Juan D.

    2008-01-01

    Radiation Protection issues concerning patients, public and staff must be considered carefully in hemodialysis for chronic renal failure patients scheduled for 131 I high dose therapy. In order to assess the risks related to this medical procedure, hemodialysis clearance of 131 I and contamination measurements were carried out. We have studied 12 hemodialysis procedures corresponding to 2 cases of hyperthyroidism disease (555MBq of 131 I administered) and 3 patients with carcinoma of the thyroid (5550 MBq of 131 I administered). The arterio-venous difference of 131 I across the artificial kidney and dose rate reduction at one meter of patient were measured. Contamination levels of the dialyser machine, filters and tubes were measured after dialysis with a contamination monitor. Direct read-out dosimeters were used to assess the radiation doses to nursery staff involved. The result obtained for mean 131 I clearance in blood was 75±11%. The mean dose rate reduction at one meter of the patient was 58±18%. We also checked that contamination levels for the dialyser machine, filters, tubes and accessories were lower than 10Bq/cm 2 . For the nursery staff the radiation dose was found to be lower than 0.1mSv. (author)

  4. Using ion-selective electrode for determining iodine-131 preparation specific activity

    International Nuclear Information System (INIS)

    Melnik, M.I.; Nazirova, T.E.

    2002-01-01

    A pilot facility was developed in 2000 for the production of iodine-131. The parameters of the preparation are as follows: chemical form: sodium iodide solution (NaI-131) in a carbonate-bicarbonate buffer (or in 0.001M NaOH); specific activity: carrier free (> 5 Ci/mg); solution pH: 7-10; radionuclide purity: > 99.9%; radiochemical purity: > 97%; bulk activity: 0.15 Ci/ml. The experimental results of investigation aimed at the determination of the specific activity of the I-131 preparation using a iodine-selective electrode are described. The method enables the analytical concentration of iodide ions in the carbonate-bicarbonate buffer (pH = 8-11) and NaOH solution (0.01 mol/l, pH = 8-11) to be determined. A micro-cell has been developed for the analysis of the I-131 solution allowing the sample volume to be reduced to below 0.3 ml. The relative error of determination of the analytical concentration of iodide (10 -6 to 10 -1 mol/l) does not exceed 1%

  5. Dynamics of an elastic capsule in moderate Reynolds number Poiseuille flow

    International Nuclear Information System (INIS)

    Shin, Soo Jai; Sung, Hyung Jin

    2012-01-01

    Highlights: ► Dynamics of a capsule in moderate Re Poiseuille flow were explored numerically. ► Capsule tends to tumbling motion for larger membrane elasticity and higher Re flow. ► Capsule undergoes swinging motion for larger size and aspect ratio of the capsule. ► Capsule tends to migrate to a specific lateral equilibrium as Re increases. ► Equilibrium position varies differently around the transition of the dynamic motion. - Abstract: The dynamic motions and lateral equilibrium positions of a two-dimensional elastic capsule in a Poiseuille flow were explored at moderate Reynolds number (10 ⩽ Re ⩽ 100) as a function of the initial lateral position (y 0 ), Re, aspect ratio (ε), size ratio (λ), membrane stretching coefficient (φ) and bending coefficient (γ). The transition between tank-treading (TT) and swinging (SW) to tumbling (TU) motions was observed and the lateral equilibrium positions of the capsules varied according to the conditions. The initial behavior of the elastic capsule was influenced by variation in the initial lateral position (y 0 ), but the equilibrium position and dynamic motion of the capsule were not affected by such variation. The capsules had a stronger tendency toward TU motion at higher values of Re, φ and γ, whereas the capsules underwent TT or SW motion as the values of ε and λ increased. Under moderate Re Poiseuille flows, capsules tended to migrate across streamlines to a specific equilibrium position. The lateral equilibrium position shifted toward the centerline at larger λ and migrated toward the wall at larger ε,φandγ. As Re increased, the equilibrium position first shifted toward the bottom wall, then toward the channel center. However, different equilibrium position trends were obtained around the SW–TU transition. The capsule undergoing TU motion tended to migrate downward toward the bottom wall more than the capsule undergoing SW motion, all other conditions being similar.

  6. Exposure to iodine 131 during the supply of capsules used for ira-therapy: comparative study of three measurement systems; Exposition a l'iode 131 lors de la dispensation des gelules utilisees pour l'iratherapie: etude comparative de trois systemes de mesure

    Energy Technology Data Exchange (ETDEWEB)

    Moubarik, C.; Giraud, F.; Bourrelly, M.; Guillet, B.; Pisano, P. [Service de medecine nucleaire, CHU de la Timone, Marseille, (France)

    2009-05-15

    The objective was to study the efficiency in the field of radiation protection of the new handle elaborated by the Covidien laboratories. In conclusions, this new handle seems to be the most efficient system in term of radiation protection of hands extremities. Indeed, it allows to reduce of 70% the exposure to extremities during the distribution of iodine 131 capsules. This supplementary protection comes from a better ergonomics and from the presence of a lead shield on the new prehension handle of Covidien laboratories. (N.C.)

  7. Sub-stoichiometric isotope dilution analysis method for the determination of iodine in common salts using iodine-131 tracer

    International Nuclear Information System (INIS)

    Singh, Vivek; Garg, A.N.

    1994-01-01

    A sub-stoichiometric isotope dilution analysis (SIDA) method was developed for the determination of iodine in different brands of common salts. An aqueous salt solution containing 131 I tracer and NaI as carrier is oxidized by tartaric acid and KIO 3 and the liberated iodine is extracted with CCl 4 . To the extract an aqueous solution of AgNO 3 is added in substoichiometric amount to obtain a colloidal solution of AgI. On adding sodium thiosulfate solution, the NaI so formed passes into aqueous solution, which is then counted. Several different brands of salt were analysed. The method is especially suitable for the determination of microgram amounts of iodide in the presence of excess of chloride. (Author)

  8. The NAi effect: creating architecture culture

    NARCIS (Netherlands)

    Figueiredo, S.M.

    2016-01-01

    At a time when cultural institutions (both in the Netherlands and abroad) are adjusting to new societal and political conditions (and financial restrictions), The NAi Effect aims to elucidate the social and cultural aims of architecture museums and their impact in creating architecture culture.

  9. Preparation of a radioactive boron compound (B-I-131-lipiodol) for neutron capture therapy of hepatoma

    International Nuclear Information System (INIS)

    Chou, F.I.; Chung, H.P.; Chung, R.J.; Wen, H.W.; Wei, Y.Y.; Kai, J.J.; Lui, W.Y.; Chi, C.W.

    2000-01-01

    In our research, a radioactive boron compound, B-I-131-lipiodol, that can be selectively retained in hepatoma cells was prepared. Combining the effect of α particles produced by boron neutron capture reaction with the β particles released by radionuclides in the radioactive boron compounds will produce a synergistic killing effect on cancer cells. Human hepatoma HepG2 cell cultures were used to examine the stability and the intracellular distribution of the radioactive boron drug. Microscopes were used to examine the interaction and retention of B-I-131-lipiodol globules in the individual hepatoma cell. Moreover, ICP-AES and NaI scintillation counter were performed to determine boron concentrations and I-131 radioactivity, respectively. Results showed that B-I-131-lipiodol with a boron concentration and a specific radioactivity ranged from 500-2000 ppm and 0.05-10 mCi/mL respectively was stably retained in serum. The radiochemical purity of B-I-131-lipiodol was 98%. After supplement with a medium containing B-I-131-lipiodol, the HepG2 cells had intracellular B-I-131-lipiodol globules in the cytoplasm as seen by inverted light microscope, the I-131 and boron can be stably retained in HepG2 cells. (author)

  10. Recommendations for the measurement 131I in human thyroid using a detector of NaI(Tl)

    International Nuclear Information System (INIS)

    Puerta Yepes, N.; Rojo, A.M.; Andres, P.A.

    2010-01-01

    The Argentine Total Body Counter Laboratory of the Nuclear Regulatory Authority participated in the last regional intercomparison Exercise organized in the frame of the IAEA Project RLA 9/066 related with in vivo measurements of 131 I in the thyroid. There were identified some difficulties in determining the efficiency and calibration factor (CF) for the 131 I when a source of 133 Ba and a detector of NaI (Tl) are used in the calibration process. Independent measurements were performed for two calibration sources of known activity ( 133 Ba and 131 I) with identical geometry pattern and using a gamma spectrometry system with NaI(Ti) detector. It was found that the region of interest (ROI) which, both in the spectrum of 133 Ba as in the spectrum of 131 I, had the same efficiency. It was determined the activity of the source of 133 Ba , distributed in the intercomparison, and the calibrated source of 131 I using different values of efficiency and FC obtained. It was analyzed the conditions under which the use of 133 Ba as a source of calibration is effective for the measurement of 131 I. (authors) [es

  11. Expanding the potential of NAI-107 for treating serious ESKAPE pathogens

    DEFF Research Database (Denmark)

    Brunati, Cristina; Thomsen, Thomas T; Gaspari, Eleonora

    2018-01-01

    Objectives: To characterize NAI-107 and related lantibiotics for their in vitro activity against Gram-negative pathogens, alone or in combination with polymyxin, and against non-dividing cells or biofilms of Staphylococcus aureus. NAI-107 was also evaluated for its propensity to select or induce...... showed that NAI-107 and its brominated variant are highly active against Neisseria gonorrhoeae and some other fastidious Gram-negative pathogens. Furthermore, all compounds strongly synergized with polymyxin against Acinetobacter baumannii, Escherichia coli, Klebsiella pneumoniae and Pseudomonas...... self-resistance in Gram-positive bacteria. Methods: We used MIC determinations and chequerboard experiments to establish the antibacterial activity of the examined compounds against target microorganisms. Time-kill assays were used to evaluate killing of exponential and stationary-phase cells...

  12. Iodine-131 imaging using 284 keV photons with a small animal CZT-SPECT system dedicated to low-medium-energy photon detection.

    Science.gov (United States)

    Kojima, Akihiro; Gotoh, Kumiko; Shimamoto, Masako; Hasegawa, Koki; Okada, Seiji

    2016-02-01

    Iodine-131 is widely used for radionuclide therapy because of its β-particle and for diagnostic imaging employing its principal gamma ray. Since that principal gamma ray has the relatively high energy of 364 keV, small animal single-photon emission computed tomography (SPECT) imaging systems may be required to possess the ability to image such higher energy photons. The aim of this study was to investigate the possibility of imaging I-131 using its 284 keV photons instead of its 364 keV photons in a small animal SPECT imaging system dedicated to the detection of low-medium-energy photons (below 300 keV). The imaging system used was a commercially available preclinical SPECT instrument with CZT detectors that was equipped with multi-pinhole collimators and was accompanied by a CT imager. An energy window for I-131 imaging was set to a photopeak of 284 keV with a low abundance compared with 364 keV photons. Small line sources and two mice, one of each of two types, that were injected with NaI-131 were scanned. Although higher counts occurred at the peripheral region of the reconstructed images due to the collimator penetration by the 364 keV photons, the shape of the small line sources could be well visualized. The measured spatial resolution was relatively poor (~1.9 mm for full width at half maximum and ~3.9 mm for full width at tenth maximum). However, a good linear correlation between SPECT values and the level of I-131 radioactivity was observed. Furthermore, the uptake of NaI-131 to the thyroid gland for the two mice was clearly identified in the 3D-SPECT image fused with the X-ray CT image. We conclude that the use of an energy window set on the photopeak of 284 keV and the multi-pinhole collimator may permit I-131 imaging for a preclinical CZT-SPECT system that does not have the ability to acquire images using the 364 keV photons.

  13. Evaluation of detectors for blood bioanalysis in Lu-177 and I-131 therapies for bone marrow dosimetry; Avaliacao de detectores para bioanalise de sangue em terapias com Lu-177 and I-131 para dosimetria de medula ossea

    Energy Technology Data Exchange (ETDEWEB)

    Degenhardt, Amilie Louize

    2016-10-01

    The measures traceability is mandatory for minimizing uncertainties in internal dosimetry for radiopharmaceuticals clinical studies and ensures the quality of the standard. Equipment should have resolution and efficiency compatible with radionuclides energies and, additionally, be able to quantify variations in human bodies' activities samples since the initial administration near the minimum residual activities. For testing three equipment (ionization chamber Capintec 25R, sodium iodine scintillator LTI Genesys Gamma-1 and high hyperpure germanium detector Canberra), they were prepared Lu-177 and I-131 radiation sources simulating patient's blood samples activities by adopting the following hypothesis: (1) initial activities according the Brazilian protocols; (2) blood volume in the whole body (5.3 L for adult men and 1.4 L for 5 years-old children); (3) effective half-lives (1.61 h and 42.9 h for Lu-177 bi-exponential adjustment and 15.7 h for I-131 mono-exponential adjustment); (4) sampling between 30 min and 168 h; (v) blood density adjustments. The standard sources were measured in the secondary standard ionization chamber Centronics IG11 at the Laboratorio Nacional de Metrologia das Radiacoes Ionizantes. The Capintec ionization chamber efficiencies ranged, respectively for I-131 and Lu-177, between (111.58±0.02)% and (102.27±0.01)% and HPGe semiconductor detector efficiencies ranged, respectively, between (89.40±0.03)% and (87.80±0.04)%. For the NaI detector, when the Lu-177 sources were positioned inside the detector the efficiencies ranged between (12.66±0.01)% and (11.54± 0.07)% and when the sources were positioned at 5 cm and 10 cm from the detector the efficiencies decreased to less than 5%. For I-131 sources positioned inside the detector, the efficiencies ranged between (29.76±0.21)% and (30.20±0.04)% and they decreased to less than 5% when they were positioned at 5 cm and 10 cm from the detector (deviation greater than 95

  14. Evaluation of detectors for blood bioanalysis in Lu-177 and I-131 therapies for bone marrow dosimetry

    International Nuclear Information System (INIS)

    Degenhardt, Amilie Louize

    2016-01-01

    The measures traceability is mandatory for minimizing uncertainties in internal dosimetry for radiopharmaceuticals clinical studies and ensures the quality of the standard. Equipment should have resolution and efficiency compatible with radionuclides energies and, additionally, be able to quantify variations in human bodies' activities samples since the initial administration near the minimum residual activities. For testing three equipment (ionization chamber Capintec 25R, sodium iodine scintillator LTI Genesys Gamma-1 and high hyperpure germanium detector Canberra), they were prepared Lu-177 and I-131 radiation sources simulating patient's blood samples activities by adopting the following hypothesis: (1) initial activities according the Brazilian protocols; (2) blood volume in the whole body (5.3 L for adult men and 1.4 L for 5 years-old children); (3) effective half-lives (1.61 h and 42.9 h for Lu-177 bi-exponential adjustment and 15.7 h for I-131 mono-exponential adjustment); (4) sampling between 30 min and 168 h; (v) blood density adjustments. The standard sources were measured in the secondary standard ionization chamber Centronics IG11 at the Laboratorio Nacional de Metrologia das Radiacoes Ionizantes. The Capintec ionization chamber efficiencies ranged, respectively for I-131 and Lu-177, between (111.58±0.02)% and (102.27±0.01)% and HPGe semiconductor detector efficiencies ranged, respectively, between (89.40±0.03)% and (87.80±0.04)%. For the NaI detector, when the Lu-177 sources were positioned inside the detector the efficiencies ranged between (12.66±0.01)% and (11.54± 0.07)% and when the sources were positioned at 5 cm and 10 cm from the detector the efficiencies decreased to less than 5%. For I-131 sources positioned inside the detector, the efficiencies ranged between (29.76±0.21)% and (30.20±0.04)% and they decreased to less than 5% when they were positioned at 5 cm and 10 cm from the detector (deviation greater than 95

  15. Expanding the potential of NAI-107 for treating serious ESKAPE pathogens

    DEFF Research Database (Denmark)

    Brunati, Cristina; Thomsen, Thomas Thyge; Gaspari, Eleonora

    2018-01-01

    self-resistance in Gram-positive bacteria. Methods: We used MIC determinations and chequerboard experiments to establish the antibacterial activity of the examined compounds against target microorganisms. Time-kill assays were used to evaluate killing of exponential and stationary-phase cells...... biofilms. As expected for a lipid II binder, no significant resistance to NAI-107 was observed by direct plating or serial passages. Conclusions: Overall, the results of the current work, along with previously published results on the efficacy of NAI-107 in experimental models of infection, indicate...

  16. Gamma ray energy loss spectra simulation in NaI detectors with the Monte Carlo method

    International Nuclear Information System (INIS)

    Vieira, W.J.

    1982-01-01

    With the aim of studying and applying the Monte Carlo method, a computer code was developed to calculate the pulse height spectra and detector efficiencies for gamma rays incident on NaI (Tl) crystals. The basic detector processes in NaI (Tl) detectors are given together with an outline of Monte Carlo methods and a general review of relevant published works. A detailed description of the application of Monte Carlo methods to ν-ray detection in NaI (Tl) detectors is given. Comparisons are made with published, calculated and experimental, data. (Author) [pt

  17. Thyroid remnant ablation using 1,110 MBq of I-131 after total thyroidectomy. Regulatory considerations on release of patients after unsealed radioiodine therapy

    International Nuclear Information System (INIS)

    Kusakabe, Kiyoko; Yokoyama, Kunihiko; Ito, Koichi

    2012-01-01

    This study was undertaken to measure the radiation exposure level of caregivers following outpatient NaI (I-131) 1,110 MBq therapy for remnant thyroid ablation after total thyroidectomy in patients with differentiated thyroid cancer, and to evaluate the influence of activities of daily living on radiation exposure level, with the goal of proposing an optimum method of I-131 therapy. The study included 37 patients with differentiated thyroid cancer, who had undergone total thyroidectomy and received outpatient based remnant thyroid ablation using NaI (I-131) 1,110 MBq, who were satisfying the following requirements: patients who have no evidence of distant metastases, whose living environments were appropriate for outpatient I-131 (1,110 MBq) therapy, and patients who gave written informed consent. The dose rate at a distance of 1 m from the body surface of the patient at the moment of release was measured using survey meters of the GM type or ionization chamber type. The dose level for the caregiver was measured with a personal dosimeter in all cases. The dose rate at a distance of 1 m from the patient's body surface 1 h after I-131 administration was in the range of 29-115 μSv/h (mean 63.8 μSv/h). The 7-day cumulative effective dose of caregivers was 0.11±0.08 mSv, on an average, in 34 dosimeters. In 31 of 34 dosimeters, cumulative effective dose of caregivers was below 0.2 mSv. Dose levels exceeding 0.2 mSv were recorded in 3 cases (0.21, 0.35 and 0.43 mSv in one case each). These results suggest that the exposure level of family members (caregiver and others) was minimal and is lower than the radiation levels affecting human environments. Outpatient-based remnant thyroid ablation with I-131 (1,110 MBq) performed after total thyroidectomy in patients with differentiated thyroid cancer is safe if applied in accordance with the appropriate supervision and guidance by experts with certain qualifications. (author)

  18. Investigation and thermodynamic calculation of phase diagram of CdI2-PbI2-NaI system

    International Nuclear Information System (INIS)

    Storonkin, A.V.; Vasil'kova, I.V.; Korobkov, S.V.

    1976-01-01

    Using the thermographic and X-ray phase analyses binary CdI 2 -PbI 2 , PI 2 -NaI, CdI 2 -NaI systems and a triple CdI 2 -PbI 2 -NaI system are investigated and their melting diagrams are plotted. A method of thermodynamic calculation has been proposed and tested of the shape of the eutectic lines for the system CdI 2 -PbI 2 -NaI, taking into account the non-ideality of the liquid phase. The method uses data obtained for the binary systems. The liquidus surface of the triple system has been constructed on the basis of the calculation. The results of the calculation of the triple eutectics are in good agreement with the experimental data

  19. Nose swabs and urinalysis as indicators of exposure to I-131

    Energy Technology Data Exchange (ETDEWEB)

    Barrall, R. C.

    1963-06-15

    During a maintenance operation on the Aromour Research Reactor, a heat lamp, which was drying a valve, caused a small quantity of I/sup 131/ become airborne. A continuous air monitor sampling in the area gave the alarm and the area ntified by the use of a 256 channel analyzer. Nose swabs of the personnel involved were taken and 24 hour urine samples were obtained. A single channel analyzer was set up, calibrated for I/sup 131/ and thyroid counts were started several hours after the incident. The thyroid count rose during the first 24 hour period and then declined closely following the 8 day half life of I/sup 131/. The urine Samples were analyzed by two different gamma counting techniques. Portions of the 24 hour urine sample were also sent to a commercial urinalysis service and analysis for I/sup 131/specifically requested. The results of the commercial service in this instance appeared to be poor. Nose swabs taken immediately after the incident were analyzed using a NaI well crystal. The average value of the ratio mu c on nose swabs to mu c in thyroid was found to be 2.6 x 1-/sup -1/ with all values within a factor of 6. The average value of the ratio mu c in 24 hour urine sample to mu c in thyroid was 5.7 with all values within a factor of 2. It would appear that at short times after a suspected exposure to I/sup 131/ nose swabs and urine samples are both useful in making a rapid assessment of exposure. The data presented are based on 10 subjects. (auth)

  20. Transmural gradients in Na/K pump activity and [Na+]I in canine ventricle.

    Science.gov (United States)

    Gao, J; Wang, W; Cohen, I S; Mathias, R T

    2005-09-01

    There are well-documented differences in ion channel activity and action potential shape between epicardial (EPI), midmyocardial (MID), and endocardial (ENDO) ventricular myocytes. The purpose of this study was to determine if differences exist in Na/K pump activity. The whole cell patch-clamp was used to measure Na/K pump current (I(P)) and inward background Na(+)-current (I(inb)) in cells isolated from canine left ventricle. All currents were normalized to membrane capacitance. I(P) was measured as the current blocked by a saturating concentration of dihydro-ouabain. [Na(+)](i) was measured using SBFI-AM. I(P)(ENDO) (0.34 +/- 0.04 pA/pF, n = 17) was smaller than I(P)(EPI) (0.68 +/- 0.09 pA/pF, n = 38); the ratio was 0.50 with I(P)(MID) being intermediate (0.53 +/- 0.13 pA/pF, n = 19). The dependence of I(P) on [Na(+)](i) or voltage was essentially identical in EPI and ENDO (half-maximal activation at 9-10 mM [Na(+)](i) or approximately -90 mV). Increasing [K(+)](o) from 5.4 to 15 mM caused both I(P)(ENDO) and I(P)(EPI) to increase, but the ratio remained approximately 0.5. I(inb) in EPI and ENDO were nearly identical ( approximately 0.6 pA/pF). Physiological [Na(+)](i) was lower in EPI (7 +/- 2 mM, n = 31) than ENDO (12 +/- 3 mM, n = 29), with MID being intermediate (9 +/- 3 mM, n = 22). When cells were paced at 2 Hz, [Na(+)](i) increased but the differences persisted (ENDO 14 +/- 3 mM, n = 10; EPI 9 +/- 2 mM, n = 10; and MID intermediate, 11 +/- 2 mM, n = 9). Based on these results, the larger I(P) in EPI appears to reflect a higher maximum turnover rate, which implies either a larger number of active pumps or a higher turnover rate per pump protein. The transmural gradient in [Na(+)](i) means physiological I(P) is approximately uniform across the ventricular wall, whereas transporters that utilize the transmembrane electrochemical gradient for Na(+), such as Na/Ca exchange, have a larger driving force in EPI than ENDO.

  1. Radiation safety implications of 131I treatment in a patient with Grave's disease undergoing home hemodialysis.

    Science.gov (United States)

    Simpson, J B; Godwin, G A

    2006-12-01

    The radiation safety implications following the administration of 131I for the treatment of Grave's disease to a patient undergoing home-based renal dialysis was investigated. External dose-rate measurements from the patient revealed a peak value at around day 2, post administration. The effective half-life was determined as 6.5 d. From day 3, the clearance of 131I was observed to be fairly constant and equated to 2.7% per day or 5.4% per dialysis session. From this the biological half-life was determined as 15 d. Radiation monitoring of the dialysis unit, disposables, and bed linen found no detectable contamination. For the purpose of useful protection, at a distance of 1 m from the patient, the average dose rate over the effective treatment duration was determined to be 8 microSv h(-1) and at 2 m distance, 2.6 microSv h(-1). Thus, in order to keep below a level of dose constraint of 3 mSv the total allowable time spent at 1 m would be 375 h or 15 h per day. To comply with a 1-mSv constraint, the average daily exposure allowable at 1 m would be 5 h per day. Neither of these time limits would be difficult to achieve for the majority of situations with fairly modest behavioral constraints. Initial discharge concentration rates into the waste water system are estimated at 200 MBq m(-3) and therefore might need to be considered depending upon the regulatory environment.

  2. Rapid measurement of 131I in the thyroid gland using a portable Ge system

    International Nuclear Information System (INIS)

    Kawamura, H.; Kimura, S.

    2000-01-01

    Rapid yet accurate measurement of the 131 I activity in the thyroid gland as well as in the air, water and vegetation may have an important role in obtaining quantitative information on internal doses for the people living in the vicinity of nuclear facilities shortly after an accidental release of radionuclides. Whole body counting technique is still the standard method for measuring radionuclides in the body while necessity for in situ measurement techniques has considerably increased especially after the Three Mile Island and Chernobyl accidents. For measurement of 131 I in the thyroid gland in emergency situations, NaI (Tl) detectors, as in a scintillation survey meter as in the simplest case, are most often used while measurement of urinary excretions for members of the public may also effective. The scintillation survey meter method, being easily implemented, may not have enough selectivity for radioiodine and even be liable to an elevated background radiation spectrum. This would possibly lead to higher detection limits and lower accuracy. A use of a laboratory Ge (Li) detector system in the thyroidal radioiodine measurement was suggested to overcome the problem. A real measurement with a similar instrument was reported for the residents in U.K. after the Chernobyl accident. A use of a scintillation spectro-survey meter with a NaI (Tl) probe with lead collimation to thyroidal radioiodine measurement was also reported to give satisfactorily accurate evaluation of the thyroidal 131 I burden. In this paper, a movable Ge system was developed for the above purpose and preliminarily evaluated particularly for counting efficiency. It is consisted of a portable high-purity Ge detector and a battery-operated MCA. It employs a laboratory made thin Pb shield with a collimation window and an elevator for the detector platform. The elevator was designed to adjust the height of the thyroid radioiodine probe in relation to the height and position of the neck of a subject

  3. Evaluation of moderately cooled pure NaI as a scintillator for position-sensitive PET detectors

    International Nuclear Information System (INIS)

    Wear, J.A.; Karp, J.S.; Haigh, A.T.; Freifelder, R.

    1996-01-01

    A new evaluation of pure NaI has been performed to determine if moderate cooling would lead to better performance than that of existing, activated NaI(Tl) position-sensitive detectors, particularly at high countrates. Using a freezer, an initial effort was performed to cool the crystal assembly to -90 C (183 K). At this temperature, pure NaI has a decay constant of 35 nsec, a light output which is about 20% that of room temperature NaI(Tl), and an energy resolution of 15%. For the PET applications the signal of room temperature (25 C) NaI(Tl) is normally pulse clipped, reducing the light output to 40% of the unclipped signal and yielding an energy resolution of 10.5%. Since the long decay of NaI(Tl) causes it to suffer more significantly than pure NaI from pre-pulse pileup, the difference in energy resolution between the two crystals at high countrates will be reduced. Also, a significantly shorter trigger deadtime with pure NaI will lead to a reduction in coincidence deadtime losses in PET. Computer simulations of large-area crystals operating at high countrates have been performed to quantify their trigger deadtime behavior and position resolution as a function of light output and pulse decay time. Having gained experience with the practical issues of cooling large crystals, measurements of position resolution have been performed with a NaI bar detector of similar geometry to the NaI(Tl) detectors in use in the PENN-PET scanner

  4. A method for synthesizing response functions of NaI detectors to gamma rays

    International Nuclear Information System (INIS)

    Sie, S.H.

    1978-08-01

    A simple method of parametrizing the response function of NaI detectors to gamma rays is described, based on decomposition of the pulse-height spectrum into components associated with the actual detection processes. Smooth dependence of the derived parameters on the gamma-ray energy made it possible to generate a lineshape for any gamma-ray energy by suitable interpolation techniques. The method is applied in analysis of spectra measured with a 7.6 x 7.6 cm NaI detector in continuum gamma-ray study following (HI,xn) reaction

  5. Transfer of 131I and /sup 95m/Tc from pasture to goat milk

    International Nuclear Information System (INIS)

    Bondietti, E.A.; Garten, C.T. Jr.

    1984-01-01

    Field measurements were made in 1983 on the transfer of 131 I and /sup 95m/Tc from spray-contaminated pasture to goat's milk. The transfer of 131 I to milk was similar to that used for mathematical models in US Nuclear Regulatory Commission Regulatory Guide 1.109, which was derived from stall-feeding experiments using capsulized doses. Compared to 131 I, the /sup 95m/Tc transferred to milk was about 5600 times less. The lower transfer resulted from both immobilization of technetium on pasture prior to ingestion as well as reduced gastrointestinal absorption. The results show that the food chain transfer of technetium to milk is much less than that previously expected based on inferences made from metabolism studies. 6 references, 4 figures, 1 table

  6. Studies on the airborne radioiodine-contamination in thyroid therapy with /sup 131/I doses of approx 370 MBq

    Energy Technology Data Exchange (ETDEWEB)

    Krzesniak, J W; Czerminska, M [Centralne Lab. Ochrony Radiologicznej, Warsaw (Poland); Chomicki, O A [Centrum Medyczne Ksztalcenia Podyplomowego, Warsaw (Poland)

    1979-01-01

    The equipment and methods are described and the results presented of /sup 131/I levels in various physical and chemical forms measured at the Endocrinology Clinic of the Center for Postgraduate Medical Training in Warsaw. The analysis was made of the radiation hazards to the personnel and ''nonradioisotope'' patient from /sup 131/I inhaled. Even though the /sup 131/I levels in the air exceeded the permissible levels by a factor 2-5, when the time spent in corresponding areas was taken into consideration, the /sup 131/I uptake in the above persons constituted only between 1 and 10% of the maximum permissible level of the /sup 131/I inhaled. The dynamics of radioiodine exhalation in the euthyroid and hyperthyroid patients treated with /sup 131/I is discussed. No statistical difference was found between the exhalation curves when /sup 131/I was administered as a liquid or in the form of closed capsules.

  7. T-1020 NaI crystal test for DM-Ice

    International Nuclear Information System (INIS)

    Maruyama, Reina; Heeger, Karsten; Pierpoint, Zachary; Pettus, Walter; Broerman, Benjamin; Hilgenberg, Chris; Webber, David

    2011-01-01

    This is a memorandum of understanding between the Fermi National Accelerator Laboratory (Fermilab) and the experiments of the NaI Crystal Test for DM-Ice from the University of Wisconsin who have committed to participate in detector tests to be carried out during the 2011-2012 Fermilab Neutrino program. The memorandum is intended primarily for the purpose of recording expectations for budget estimates and work allocations for Fermilab, the funding agencies and the participating institutions. It reflects an arrangement that currently is satisfactory to the parties; however, it is recognized and anticipated that changing circumstances of the evolving research program will necessitate revisions. The parties agree to modify this memorandum to reflect such required adjustments. Actual contractual obligations will be set forth in separate documents. The DM-Ice collaboration is designing a sodium-iodide (NaI) based detector for a direct dark matter search. The detectors should have low readout noise and background levels to carry out a sensitive search. A 17-kg version of the experiment is running at the South Pole, 2500 m deep in the Antarctic ice, and a large scale experiment is currently being designed. One of the keys to the success of the experiment is to have a good understanding of the background levels intrinsic in the NaI detectors. To measure the background level, the detectors have to be shielded against cosmic rays. The lead shielding used for DAMIC in the Minos Underground Areas is a well-suited location for this test since it offers enough overburden to shield against cosmic rays, lead shielding, and experimental infrastructure. The goal of the test is to assess the background levels in the detector and to assess the characteristics of phosphorescence induced by muons and 100 keV-3 MeV gamma rays.

  8. In vivo biological evaluation of 131I radiolabeled-paclitaxel glucuronide (131I-PAC-G)

    International Nuclear Information System (INIS)

    Aslan, O.; Biber Muftuler, F.Z.; Yurt Kilcar, A.; Ichedef, C.; Unak, P.

    2012-01-01

    Paclitaxel (PAC) is a natural occurring diterpene alkoloid originally isolated from the bark of Taxus Brevifolia. It is one of the most important antitumor agents for clinical treatment of ovarian, breast non-small cell lung and prostate cancers. It is known that these types of cancer cells have high β-glucuronidase enzyme which can catalyze the hydrolysis of glucuronides. This is why the synthesis compounds which undergo glucuronidation come into question in the imaging and therapy of these cancer cells. The aim of current study is conjugation of glucuronic acid (G) to the starting substance PAC, labeling with 131 I and to perform its in vivo biological evaluation. Glucuronic acid derived paclitaxel compound [paclitaxel-glucuronide (PAC-G)] was labeled with 131 I using iodogen method. According to thin layer radio chromatography (TLRC) method, the radiochemical yield of 131 I-PAC-G was 84.30 ± 7.40% (n=10). The biodistribution of 131 I-PAC-G in healthy female and male Wistar Albino rats has been investigated. Imaging studies on male Balb-C mice were performed by using the Kodak FX PRO in vivo Imaging System. The range of the breast/blood, breast/muscle; ovary/blood, ovary/muscle ratios is approximately between 1.29 and 11.34 in 240 min, and between 0.71 and 8.24 in 240 min for female rats. The prostate/blood and prostate/muscle ratio is between 1.94 and 6.95 in 30 min for male rats. All these experimental studies indicate that 131 I-PAC-G may potentially be used in breast, ovary and prostate tissues as an imaging agent. Also it is thought that 131 I-PAC-G bears a therapy potential because of the 131 I radionuclide and can be improved with further investigations. (orig.)

  9. Elucidating the molecular physiology of lantibiotic NAI-107 production in Microbispora ATCC-PTA-5024

    DEFF Research Database (Denmark)

    Gallo, Giuseppe; Renzone, Giovanni; Palazzotto, Emilia

    2016-01-01

    by a complex regulatory and metabolic network that may be elucidated by the integration of genomic, proteomic and bioinformatic tools. Accordingly, an extensive evaluation of the proteomic changes associated with NAI-107 production was performed on Microbispora ATCC-PTA-5024 by combining two......; ii) during three time-points (117, 140, and 162 h) at D stage characterized by different profiles of NAI-107 yield accumulation (117 and 140 h) and decrement (162 h). Regulatory, metabolic and unknown-function proteins, were identified and functionally clustered, revealing that nutritional signals......, regulatory cascades and primary metabolism shift-down trigger the accumulation of protein components involved in nitrogen and phosphate metabolism, cell wall biosynthesis/maturation, lipid metabolism, osmotic stress response, multi-drug resistance, and NAI-107 transport. The stimulating role on physiological...

  10. SYNTHESIS AND CRYSTAL STRUCTURE OF A NA(I COMPLEX WITH 4,4’-BIPYRIDINE AND 2-FORMYL- BENZENESULFONATE-HYDRAZINE

    Directory of Open Access Journals (Sweden)

    TAI XI-SHI

    2015-07-01

    Full Text Available A Na(I complex, [Na(4,4’-bipyridine2·(H2O4]·L·OH·2H2O (L = 2-formyl-benzenesulfonate-hydrazine, has been synthesized. And its structure was determined by X-ray single crystal diffraction analysis. The Na(I complex belongs to orthorhombic, space group C2221 with a = 7.9162(16 Å, b = 18.451(4 Å, c = 26.397(5 Å, V= 3855.7(13 Å3, Z = 4, Dc = 1.394 mg·m-3, μ = 0.218 mm-1, F(000 =1689, and final R1 = 0.0683, ωR2 = 0.2017. The result shows that the Na(I center is six-coordination with a N2O4 distorted octahedral coordination environment. The Na(I complex forms 1D chain structure by the π-π stacking interaction.

  11. Methodology for calibration of detector of NaI (TI)) 3 ' X 3 ' for in vivo measurements of patients with hyperthyroidism undergoing to radioiodotherapy; Metodologia para calibracao de detector de NaI(TI) ) 3'X3' para medicoes in vivo em pacientes portadores de hipertireoidismo submetidos a radioiodoterapia

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Carlaine B.; Lacerda, Isabelle V.B.; Oliveira, Mercia L.; Hazin, Clovis A., E-mail: carlaine.carvalho@gmail.com, E-mail: bellelacerda@hotmail.com, E-mail: mercial@cnen.gov.br, E-mail: chazin@cnen.gov.br [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear; Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Lima, Fabiana F., E-mail: fflima@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2013-10-01

    The aim of this study is to establish the methodology for calibration of the detection system to be used in determining the therapeutic activity of {sup 131}I required to release desired absorbed dose in the thyroid gland . This step is critical to the development of a protocol for individualized doses. The system consists of a detector of NaI (Tl ) 3'x3' coupled to software Genie 2000. We used the calibration sources of {sup 60}Co , {sup 137}Cs and {sup 133}Ba. We obtained the straight calibration system, with sources {sup 60}Co and {sup 137}Cs. Subsequently , the detector was calibrated using a thyroid phantom-neck designed and produced by the IRD / CNEN with known activity of {sup 133}Ba standard solution containing 18.7 kBq (on 09/24/12) evenly distributed. He was also calibrated with other thyroid- neck phantom model 3108 manufactured by Searle Radigraphics Ind., containing a liquid source of {sup 131}I ( 7.7 MBq ). Five measurements were performed during 5 minutes for three different distances detector-simulator and calculated the corresponding calibration factors . The values of the calibration factors found for the simulator made by IRD and Searle Radigraphics Ind. for the distances 20, 25 and 30 cm were 0.35 , 0.24, 0.18, 0.15 , 0.11, 0, 09 , respectively. With the detection system properly calibrated and the calibration factors established, the technique is suitable for the evaluation of diagnostic activities of {sup 131}I incorporated by hyperthyroid patients. (author)

  12. Three cases of respiratory failure after I-131 radioiodine therapy

    International Nuclear Information System (INIS)

    Watanabe, Ken; Uchiyama, Masayuki; Fukuda, Kunihiko

    2016-01-01

    We report three cases of respiratory failure after I-131 radioiodine therapy. All cases involved relapsed cervical lesions, and two showed edema of the larynx. Emergency tracheostomy was performed to treat the respiratory failure in one case while the others were treated conservatively. All patients showed improvements without after-effects. Patients who undergo I-131 radioiodine therapy, especially those with cervical lesions, should be carefully monitored for this rare complication after treatment. (author)

  13. Cytogenetic in thyroid carcinoma and therapy with 131{sup I}; Citogenetica en cancer de tiroides y terapia con 131''I

    Energy Technology Data Exchange (ETDEWEB)

    Popova, L.; Hadjidekova, V.; Christova, R.; Agova, S.; Grudeva, V.; Hadjieva, T.; Dominguez, I.

    2007-07-01

    In order to assess the genotoxic risk of the therapy with radioiodine-131(''131I), the production of micronuclei (MN) and chromosome aberrations (CA) were analyzed in the peripheral blood lymphocytes of group of 26 patients undergoing therapy with this radionuclide for differentiated thyroid carcinoma (DTC). Blood samples were taken immediately before ''131 I administration and 1 month later. The patients underwent radioiodine ablation (RIA) or radioiodine therapy (RIT) after radical thyroidectomy. The amount of orally administered ''131I activity varied from 3330 to 4030 MBq according to the king of therapy (RIA or RIT). results show that after radioiodine therapy there is a significant increase in the frequency of MN and CA. The mean frequencies of MN {+-} Sd before and after the therapy were 10.72 % {+-} 5.84 % and 25.28 %{+-} 12.6% respectively. For CA, the mean frequencies obtained were 1.16% {+-} 0.36% before and 2.3% {+-} 0.87% after the therapy. These findings indicate a genotoxic activity of ''131I therapy estimated after a period of one month. (Author) 38 refs.

  14. Management of thyroid carcinoma with radioactive 131I

    International Nuclear Information System (INIS)

    Paryani, Shyam B.; Chobe, Rashmi J.; Scott, Walter; Wells, John; Johnson, Douglas; Kuruvilla, Anand; Schoeppel, Sonja; Deshmukh, Abhijit; Miller, Robert; Dajani, Lorraine; Montgomery, Charles Ted; Puestow, Eric; Purcell, John; Roura, Miguel; Sutton, David; Mallett, Ruth; Peer, Jan

    1996-01-01

    Purpose: To evaluate the role of radioactive 131 I in the management of patients with well differentiated carcinoma of the thyroid. Methods and Materials: Between 1965 and 1995, a total of 117 patients with well-differentiated carcinoma of the thyroid underwent either lobectomy or thyroidectomy followed by 100-150 mCi of 131 I. Results: With a median follow-up of 8 years, only four patients (3%) developed a recurrence of their disease. The 5-year actuarial survival was 97% with a 10-year survival of 91%. There were no severe side effects noted after 131 I therapy. Conclusions: Radioactive 131 I is a safe and effective procedure for the majority of patients with well-differentiated thyroid carcinoma. We currently recommend that all patients undergo a subtotal or total thyroidectomy followed by 131 I thyroid scanning approximately 4 weeks after surgery. If the thyroid scan shows no residual uptake and all disease is confined to the thyroid, we recommend following patients with annual thyroid scans and serum thyroglobulin levels. If there is any residual uptake detected in the neck or if the tumor extends beyond the thyroid, we recommend routine thyroid ablation of 100-150 mCi of radioactive 131 I

  15. In vivo biological evaluation of {sup 131}I radiolabeled-paclitaxel glucuronide ({sup 131}I-PAC-G)

    Energy Technology Data Exchange (ETDEWEB)

    Aslan, O.; Biber Muftuler, F.Z.; Yurt Kilcar, A.; Ichedef, C.; Unak, P. [Ege Univ., Izmir (Turkey). Dept. of Nuclear Applications

    2012-07-01

    Paclitaxel (PAC) is a natural occurring diterpene alkoloid originally isolated from the bark of Taxus Brevifolia. It is one of the most important antitumor agents for clinical treatment of ovarian, breast non-small cell lung and prostate cancers. It is known that these types of cancer cells have high {beta}-glucuronidase enzyme which can catalyze the hydrolysis of glucuronides. This is why the synthesis compounds which undergo glucuronidation come into question in the imaging and therapy of these cancer cells. The aim of current study is conjugation of glucuronic acid (G) to the starting substance PAC, labeling with {sup 131}I and to perform its in vivo biological evaluation. Glucuronic acid derived paclitaxel compound [paclitaxel-glucuronide (PAC-G)] was labeled with {sup 131}I using iodogen method. According to thin layer radio chromatography (TLRC) method, the radiochemical yield of {sup 131}I-PAC-G was 84.30 {+-} 7.40% (n=10). The biodistribution of {sup 131}I-PAC-G in healthy female and male Wistar Albino rats has been investigated. Imaging studies on male Balb-C mice were performed by using the Kodak FX PRO in vivo Imaging System. The range of the breast/blood, breast/muscle; ovary/blood, ovary/muscle ratios is approximately between 1.29 and 11.34 in 240 min, and between 0.71 and 8.24 in 240 min for female rats. The prostate/blood and prostate/muscle ratio is between 1.94 and 6.95 in 30 min for male rats. All these experimental studies indicate that {sup 131}I-PAC-G may potentially be used in breast, ovary and prostate tissues as an imaging agent. Also it is thought that {sup 131}I-PAC-G bears a therapy potential because of the {sup 131}I radionuclide and can be improved with further investigations. (orig.)

  16. Small-bowel capsule endoscopy in patients with suspected Crohn's disease-diagnostic value and complications.

    Science.gov (United States)

    Figueiredo, Pedro; Almeida, Nuno; Lopes, Sandra; Duque, Gabriela; Freire, Paulo; Lérias, Clotilde; Gouveia, Hermano; Sofia, Carlos

    2010-01-01

    The aim of this work was to assess the value of capsule enteroscopy in the diagnosis of patients with suspected Crohn's Disease (CD). Methods. This was a retrospective study in a single tertiary care centre involving patients undergoing capsule enteroscopy for suspected CD. Patients taking nonsteroidal anti inflammatory drugs during the thirty preceding days or with a follow-up period of less than six months were excluded. Results. Seventy eight patients were included. The endoscopic findings included mucosal breaks in 50%, ulcerated stenosis in 5%, and villous atrophy in 4%. The diagnosis of CD was established in 31 patients. The sensitivity, specificity, positive and negative predictive value of the endoscopic findings were 93%, 80%, 77%, and 94%, respectively. Capsule retention occurred in four patients (5%). The presence of ulcerated stenosis was significantly more frequent in patients with positive inflammatory markers. The diagnostic yield of capsule enteroscopy in patients with negative ileoscopy was 56%, with a diagnostic acuity of 93%. Small bowel capsule endoscopy is a safe and valid technique for assessing patients with suspected CD. Capsule retention is more frequent in patients with positive inflammatory markers. Patients with negative ileoscopy and suspected CD should be submitted to capsule enteroscopy.

  17. An Excel-Based System to Manage Radiation Safety for the Family of Patients Undergoing 131I Therapy.

    Science.gov (United States)

    Steward, Palmer G

    2017-06-01

    The purpose of this study was to develop spreadsheet workbooks that assist in the radiation safety counseling of 131 I therapy patients and their families, providing individualized guidelines that avoid imposing overly conservative restrictions on family members and others. Methods: The mathematic model included biphasic patient radionuclide retention. The extrathyroidal component was a cylindric volume with a diameter corresponding to the patient's size and included patient self-absorption, whereas the thyroidal component was a point source whose transmission was reduced by self-absorption. A separate model in which the thyroid, extrathyroid, and bladder compartments fed serially from one to the next was developed to depict the radionuclide levels within the patient and to estimate the activity entering the environment at each urination. Results: The system was organized into a set of 4 workbooks: the first to be used with ablation patients prepared using thyrogen, the second with ablation patients prepared by deprivation, the third with hyperthyroid patients, and the fourth with the unusual hyperthyroid patient who finds the restrictions to be oppressive and returns 5-10 d after administration for a measurement and reassessment. The workbooks evaluated the radiation field strength external to the patient and indicated restrictions based on selected dose limits. To assist physicians in suggesting contamination precautions, the workbooks also evaluated the radioactivity present within the patient and the estimated discharge into the environment as a function of time. Conclusion: The workbooks that were developed assist the radiation safety counselor in individualizing radiation protection procedures for the family of patients undergoing 131 I therapy. The workbook system avoids overly conservative assumptions while permitting selection of appropriate dose limits for each individual. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  18. Energy levels of the single excited states in NaI and Na-like ions

    International Nuclear Information System (INIS)

    El-Sherbini, T.M.; Wahby, A.S.

    1987-08-01

    Energy levels of the single excited 1s 2 2s 2 2p 6 ns( 2 S), 1s 2 2s 2 2p 6 mp( 2 P), 1s 2 2s 2 2p 6 md( 2 D) and 1s 2 2s 2 2p 6 nf( 2 F); n=4-7, m=3-6 states for NaI and Na-like ions are calculated using the one configuration Hartree-Fock method. Good agreement is obtained between our results for the higher members of the NaI sequence and previous data from photo-absorption and beam foil experiments. (author). 11 refs, 3 figs, 9 tabs

  19. Radiolabeling of codeine with 131I and its biodistribution in rats

    International Nuclear Information System (INIS)

    Enginar, H.

    2009-01-01

    Codeine which was extracted from dry capsules of the opium poppy (Papaver somniferum) was purified by HPLC (High Performance Liquid Chromatography) and characterized by NMR (Nuclear Magnetic Resonance) and IR (Infrared) spectroscopy techniques. The purified compound was labeled with 131 I and biodistribution studies were performed in rats. Radioiodinated codeine distributed uniformly in the cerebellum, m.pons, striatum and hypothalamus while the other branch of brain and Stomach, urinary bladder, and small intestine uptakes were significantly higher than other tissues. (author)

  20. Car-borne survey measurements with a 3x3` NaI detector

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, E.; Ugletveit, F.; Floe, L.; Mikkelborg, O. [Norwegian Radiation Protection Authority, Oesteraas (Norway)

    1997-12-31

    The Norwegian Radiation Protection Authority (NRPA) took part in the international survey measurement exercise RESUME95 that was arranged in Finland in August 1995. NRPA performed measurements with a simple car-borne measuring system based on standard equipment, a 3x3` NaI detector, an MCA and a GPS connected to a portable PC. The results show substantial variations in dose rate inside areas of a few square kilometres. Spectrum analysis shows that a major part of these differences are caused by variations in deposition of {sup 137}Cs. Our results show that even standard 3x3` NaI detectors can be used for car based survey measurements in fall out situations and search for sources. The detection limits are higher than for larger detectors, but the main limiting factor seem to be the timing capabilities of the acquisition system. (au).

  1. Car-borne survey measurements with a 3x3' NaI detector

    International Nuclear Information System (INIS)

    Larsen, E.; Ugletveit, F.; Floe, L.; Mikkelborg, O.

    1997-01-01

    The Norwegian Radiation Protection Authority (NRPA) took part in the international survey measurement exercise RESUME95 that was arranged in Finland in August 1995. NRPA performed measurements with a simple car-borne measuring system based on standard equipment, a 3x3' NaI detector, an MCA and a GPS connected to a portable PC. The results show substantial variations in dose rate inside areas of a few square kilometres. Spectrum analysis shows that a major part of these differences are caused by variations in deposition of 137 Cs. Our results show that even standard 3x3' NaI detectors can be used for car based survey measurements in fall out situations and search for sources. The detection limits are higher than for larger detectors, but the main limiting factor seem to be the timing capabilities of the acquisition system. (au)

  2. Car-borne survey measurements with a 3x3` NaI detector

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, E; Ugletveit, F; Floe, L; Mikkelborg, O [Norwegian Radiation Protection Authority, Oesteraas (Norway)

    1998-12-31

    The Norwegian Radiation Protection Authority (NRPA) took part in the international survey measurement exercise RESUME95 that was arranged in Finland in August 1995. NRPA performed measurements with a simple car-borne measuring system based on standard equipment, a 3x3` NaI detector, an MCA and a GPS connected to a portable PC. The results show substantial variations in dose rate inside areas of a few square kilometres. Spectrum analysis shows that a major part of these differences are caused by variations in deposition of {sup 137}Cs. Our results show that even standard 3x3` NaI detectors can be used for car based survey measurements in fall out situations and search for sources. The detection limits are higher than for larger detectors, but the main limiting factor seem to be the timing capabilities of the acquisition system. (au).

  3. Hydrocolloid liquid-core capsules for the removal of heavy-metal cations from water

    Energy Technology Data Exchange (ETDEWEB)

    Nussinovitch, A., E-mail: amos.nussi@mail.huji.ac.il; Dagan, O.

    2015-12-15

    Highlights: • Novel liquid-core capsules with a non-crosslinked alginate core were produced. • Capsules demonstrated highest efficiency adsorption of ∼300 mg Pb{sup 2+}/g alginate. • Regeneration was carried out by suspending capsules in 1 M HNO{sub 3} for 24 h. • Adsorption capacities of the capsules followed the order: Pb{sup 2+} > Cu{sup 2+} > Cd{sup 2+} > Ni{sup 2+}. - Abstract: Liquid-core capsules with a non-crosslinked alginate fluidic core surrounded by a gellan membrane were produced in a single step to investigate their ability to adsorb heavy metal cations. The liquid-core gellan–alginate capsules, produced by dropping alginate solution with magnesium cations into gellan solution, were extremely efficient at adsorbing lead cations (267 mg Pb{sup 2+}/g dry alginate) at 25 °C and pH 5.5. However, these capsules were very weak and brittle, and an external strengthening capsule was added by using magnesium cations. The membrane was then thinned with the surfactant lecithin, producing capsules with better adsorption attributes (316 mg Pb{sup +2}/g dry alginate vs. 267 mg Pb{sup +2}/g dry alginate without lecithin), most likely due to the thinner membrane and enhanced mass transfer. The capsules’ ability to adsorb other heavy-metal cations – copper (Cu{sup 2+}), cadmium (Cd{sup 2+}) and nickel (Ni{sup 2+}) – was tested. Adsorption efficiencies were 219, 197 and 65 mg/g, respectively, and were correlated with the cation’s affinity to alginate. Capsules with the sorbed heavy metals were regenerated by placing in a 1 M nitric acid suspension for 24 h. Capsules could undergo three regeneration cycles before becoming damaged.

  4. Small-Bowel Capsule Endoscopy in Patients with Suspected Crohn's Disease—Diagnostic Value and Complications

    Science.gov (United States)

    Figueiredo, Pedro; Almeida, Nuno; Lopes, Sandra; Duque, Gabriela; Freire, Paulo; Lérias, Clotilde; Gouveia, Hermano; Sofia, Carlos

    2010-01-01

    Background. The aim of this work was to assess the value of capsule enteroscopy in the diagnosis of patients with suspected Crohn's Disease (CD). Methods. This was a retrospective study in a single tertiary care centre involving patients undergoing capsule enteroscopy for suspected CD. Patients taking nonsteroidal anti inflammatory drugs during the thirty preceding days or with a follow-up period of less than six months were excluded. Results. Seventy eight patients were included. The endoscopic findings included mucosal breaks in 50%, ulcerated stenosis in 5%, and villous atrophy in 4%. The diagnosis of CD was established in 31 patients. The sensitivity, specificity, positive and negative predictive value of the endoscopic findings were 93%, 80%, 77%, and 94%, respectively. Capsule retention occurred in four patients (5%). The presence of ulcerated stenosis was significantly more frequent in patients with positive inflammatory markers. The diagnostic yield of capsule enteroscopy in patients with negative ileoscopy was 56%, with a diagnostic acuity of 93%. Conclusions. Small bowel capsule endoscopy is a safe and valid technique for assessing patients with suspected CD. Capsule retention is more frequent in patients with positive inflammatory markers. Patients with negative ileoscopy and suspected CD should be submitted to capsule enteroscopy. PMID:20811612

  5. Small-Bowel Capsule Endoscopy in Patients with Suspected Crohn's Disease—Diagnostic Value and Complications

    Directory of Open Access Journals (Sweden)

    Pedro Figueiredo

    2010-01-01

    Full Text Available Background. The aim of this work was to assess the value of capsule enteroscopy in the diagnosis of patients with suspected Crohn's Disease (CD. Methods. This was a retrospective study in a single tertiary care centre involving patients undergoing capsule enteroscopy for suspected CD. Patients taking nonsteroidal anti inflammatory drugs during the thirty preceding days or with a follow-up period of less than six months were excluded. Results. Seventy eight patients were included. The endoscopic findings included mucosal breaks in 50%, ulcerated stenosis in 5%, and villous atrophy in 4%. The diagnosis of CD was established in 31 patients. The sensitivity, specificity, positive and negative predictive value of the endoscopic findings were 93%, 80%, 77%, and 94%, respectively. Capsule retention occurred in four patients (5%. The presence of ulcerated stenosis was significantly more frequent in patients with positive inflammatory markers. The diagnostic yield of capsule enteroscopy in patients with negative ileoscopy was 56%, with a diagnostic acuity of 93%. Conclusions. Small bowel capsule endoscopy is a safe and valid technique for assessing patients with suspected CD. Capsule retention is more frequent in patients with positive inflammatory markers. Patients with negative ileoscopy and suspected CD should be submitted to capsule enteroscopy.

  6. Iodine-131 saliva secretion in ablation treatment for thyroid cancer patients

    International Nuclear Information System (INIS)

    Nascimento, Ana C.H.; Brandao, Luis E.; Candeiro, Ricardo E.; Rebelo, Ana M.O.; Corbo, Rossana; Dutra, Janaina

    2008-01-01

    In general, well-differentiated thyroid cancer treatment consists in Na 131 I administration following total or a near total thyroidectomy. The activity of a single administration in the majority of nuclear centers ranges from 1 to 4 GBq for residual thyroid tissue elimination and ranges from 4 to 8 GBq for residual thyroid tissue as well as metastases elimination. The high magnitude of 131 I activities administered for thyroid cancer treatment can lead to side effects, where salivary gland dysfunctions are the most common observed. In the absence of thyroid gland, secondary tissues - iodide specific uptake, mainly the salivary glands, rise at the element body retention process. In addition, among nuclear medicine professionals, there is no consensus about suitable restrictions that must be observed by the hospital released patient to avoid 131 I contamination by saliva. The aim of this study is to evaluate qualitatively the secretion of 131 I by salivary glands after the administration of the radionuclide to thyroid cancer patients for ablation purposes. Well-differentiated thyroid cancer patients from Clementino Fraga Filho University Hospital (HUCFF) of Federal University of Rio de Janeiro (UFRJ) followed-up in the present study are female, adult and without additional health diseases detected. After 131 I administration for ablation purposes, saliva samples were collected systematically and counting rate was assessed using a NaI(Tl) scintillator detector. As the study is at an early stage, the preliminary results concern the possibility of conducting an evaluation of 131 I secreted in saliva using the proposed protocol. It can be seen that many factors have potential to influence the behaviour of 1 31 I secretion in saliva, for example the use of Na 131 I in solution or in capsules. It was observed two standards that can be defined according to these variables. (author)

  7. X-ray escape effects in Si, Ge, and NaI detectors

    International Nuclear Information System (INIS)

    Brunner, G.

    1989-01-01

    A 3-parameter representation of the type x = K 1 [1 -L(ln(1 + 1/L))] together with L = K 2 E K 3 is recommended for the escape to parent peak ratio. Parameter values are provided for Si, Ge, and NaI detectors. Scattering, which has been neglected up to now, is included. (author)

  8. Field Observation of the Green Ocean Amazon. Neutral Cluster Air Ion Spectrometer (NAIS) Final Campaign Summary

    Energy Technology Data Exchange (ETDEWEB)

    Petaja, T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Backman, J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Manninen, H. E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wimmer, D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-03-01

    The neutral cluster and air ion spectrometer (NAIS) was deployed to the T3 site for Intensive Operations Periods 1 and 2 (IOP1 and IOP2). The NAIS is an instrument that measures aerosol particle and ion number size distributions in the mobility diameter range of 0.8 to 42 nm, corresponding to electrical mobility range between 3.2 and 0.0013 cm2 V-1 s-1. New particle formation (NPF) events were detected using the NAIS at the T3 field site during IOP1 and IOP2. Secondary NPF is a globally important source of aerosol number. To fully explain atmospheric NPF and subsequent growth, we need to directly measure the initial steps of the formation processes in different environments, including rain forest. Particle formation characteristics, such as formation and growth rates, were used as indicators of the relevant processes and participating compounds in the initial formation. In a case of parallel ion and neutral cluster measurements, we estimated the relative contribution of ion-induced and neutral nucleation to the total particle formation.

  9. Evaluation of radiation safety from patients with thyroid disease undergoing iodine-131 therapy

    International Nuclear Information System (INIS)

    Lu, K.-Y.; Li, X.F.; Liu, J.-Z.; Li, S.-J.; Hu, G.

    2007-01-01

    Full text: Objective: By calculating the dose equivalent of patients with thyroid disease who had received iodine-131 therapy, based on the China national criteria, we evaluate the radiation safety of the individuals other than the patients who had turned into a specific 'radiant source'. Methods: 152 outpatients and inpatients, with iodine-131 therapy had been investigated and followed-up. There were 162 treatments which included patients with hyperthyroidism (HT)-124, 35 thyroid cancers (TC), 2 toxic thyroid adenomas and 1 nontoxic nodular goiter. In addition, we had achieved the practical measures and contact instance with household members and the general public, including 37 HT (contact with 37 adults and 8 infants) and 3 TC. According to the personal condition of the patients and the time of exposure to individuals other than patients, and to calculate the exposure dose (mSv) to the individuals with formulae. Results: Based on the national criteria the total dose equivalent to the individuals other than patients may not exceed 5 mSv. For most patients, including 124 HT, 2 toxic thyroid adenomas and 16 times treatment of TC, the exposure doses to the individuals were not likely to exceed 5 mSv, but the others, including 19 treatments of TC and 1 nontoxic nodular goiter, the exposure doses were higher than 5 mSv. There was no difference between the part of HT and TC of inpatients when compared with outpatients (P>0.05, respectively). We found that occupancy factor during the preequilibrium period play an important role on the exposure doses to the individuals, especially TC patients. With the dose equivalent to the same HT patient, practical measures for accumulating doses is higher and more practical than the simplistic formula calculating ones (P 0.05). Conclusions: Most of the outpatients with iodine- 131 therapy were safe to the individuals surrounding them within 1 meter, but the part of TC patients needed to be treated in the hospital and took a dose

  10. Assessments of whole body scan images (PCI) obtained in patients undergoing treatment of radioiodine (pre and post-treatment)

    International Nuclear Information System (INIS)

    Costa, Fernanda Karolina Mendonca da; Lopes Filho, Ferdinand de Jesus; Vieira, Jose Wilson; Souza, Milena Thays Barbosa de

    2014-01-01

    Nuclear medicine is a medical specialty used for diagnosis and therapy of some diseases. For the treatment of differentiated thyroid carcinoma (papillary and follicular) Radioiodine therapy is employed, in order to eliminate the rest of thyroid tissue after removal of the thyroid (thyroidectomy). In radioiodine therapy is used radioisotope iodine-131 ( 131 I) as Sodium Iodide (NaI). The amount of the activity (dose) of 131 I administered is generally the responsibility of nuclear medicine, which is based on an image Research Length of the patient (pre-dose therapy PCI). PCI is also used after treatment (post-PCI therapeutic dose) to evaluate possible metastasis. The purpose of this study was to investigate the distribution of biokinetic 131 I at length and in some organs of the patient, in order to note any similarity. Exams PCI pre-dose and post-dose were analyzed, the anterior and posterior projections of ten patients. Contours in these images (ROI - Region Of Interest) were made in the whole body and in areas with high uptake of 131 I. The total score was used in the calculation to obtain the percentage distribution of 13I in the organs of the patient. The results showed that there similarity on the biodistribution of 131 I between pre-dose and post-dose PCI. Therefore, it was found that it is valuable images of PCI pre-dose therapy as a way to assist the nuclear medicine physician in choosing the best activity to be administered to the patient in order to minimize the dose to adjacent organs. (author)

  11. Expanding the potential of NAI-107 for treating serious ESKAPE pathogens: synergistic combinations against Gram-negatives and bactericidal activity against non-dividing cells.

    Science.gov (United States)

    Brunati, Cristina; Thomsen, Thomas T; Gaspari, Eleonora; Maffioli, Sonia; Sosio, Margherita; Jabes, Daniela; Løbner-Olesen, Anders; Donadio, Stefano

    2018-02-01

    To characterize NAI-107 and related lantibiotics for their in vitro activity against Gram-negative pathogens, alone or in combination with polymyxin, and against non-dividing cells or biofilms of Staphylococcus aureus. NAI-107 was also evaluated for its propensity to select or induce self-resistance in Gram-positive bacteria. We used MIC determinations and chequerboard experiments to establish the antibacterial activity of the examined compounds against target microorganisms. Time-kill assays were used to evaluate killing of exponential and stationary-phase cells. The effects on biofilms (growth inhibition and biofilm eradication) were evaluated using biofilm-coated pegs. The frequency of spontaneous resistant mutants was evaluated by either direct plating or by continuous sub-culturing at 0.5 × MIC levels, followed by population analysis profiles. The results showed that NAI-107 and its brominated variant are highly active against Neisseria gonorrhoeae and some other fastidious Gram-negative pathogens. Furthermore, all compounds strongly synergized with polymyxin against Acinetobacter baumannii, Escherichia coli, Klebsiella pneumoniae and Pseudomonas aeruginosa, and showed bactericidal activity. Surprisingly, NAI-107 alone was bactericidal against non-dividing A. baumannii cells. Against S. aureus, NAI-107 and related lantibiotics showed strong bactericidal activity against dividing and non-dividing cells. Activity was also observed against S. aureus biofilms. As expected for a lipid II binder, no significant resistance to NAI-107 was observed by direct plating or serial passages. Overall, the results of the current work, along with previously published results on the efficacy of NAI-107 in experimental models of infection, indicate that this lantibiotic represents a promising option in addressing the serious threat of antibiotic resistance. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Antimicrobial

  12. Environmental Monitoring and Characterization of Radiation Sources on UF Campus Using a Large Volume NaI Detector

    Science.gov (United States)

    Bruner, Jesse A.; Gardiner, Hannah E.; Jordan, Kelly A.; Baciak, James E.

    2016-09-01

    Environmental radiation surveys are important for applications such as safety and regulations. This is especially true for areas exposed to emissions from nuclear reactors, such as the University of Florida Training Reactor (UFTR). At the University of Florida, surveys are performed using the RSX-1 NaI detector, developed by Radiation Solutions Inc. The detector uses incoming gamma rays and an Advanced Digital Spectrometer module to produce a linear energy spectrum. These spectra can then be analyzed in real time with a personal computer using the built in software, RadAssist. We report on radiation levels around the University of Florida campus using two mobile detection platforms, car-borne and cart-borne. The car-borne surveys provide a larger, broader map of campus radiation levels. On the other hand, cart-borne surveys provide a more detailed radiation map because of its ability to reach places on campus cars cannot go. Throughout the survey data, there are consistent radon decay product energy peaks in addition to other sources such as medical I-131 found in a large crowd of people. Finally, we investigate further applications of this mobile detection platform, such as tracking the Ar-41 plume emitted from the UFTR and detection of potential environmental hazards.

  13. Pharmacokinetic Study of a Diclofenac Sodium Capsule Filled with Enteric-coated Pellets in Healthy Chinese Volunteers by Liquid Chromatography-electrospray Ionization-tandem Mass Spectrometry.

    Science.gov (United States)

    Ma, J-Y; Liu, M; Yang, M; Zhao, H; Tong, Y; Zhang, Y; Deng, M; Liu, H

    2016-05-01

    The pharmacokinetic study of a diclofenac sodium capsule filled with enteric-coated pellets (abbreviated as CAPSULE) in healthy Chinese subjects was evaluated using liquid chromatography-electrospray ionization-tandem mass spectrometry with simple sample preparation. In a cross-over study, 12 healthy male volunteers were given 50 mg CAPSULE and diclofenac sodium enteric-coated tablet (abbreviated as TABLET, used as a control dosage form) at fasting. The Cmax, AUC0-t, and Tmax of CAPSULE were 1.01±0.52 μg/mL, 1.54±0.18 μg·h/mL, and 1.50±1.31 h, respectively. When compared with TABLET, the pharmacokinetic study showed that although this CAPSULE exhibited similar AUC (only 10% lower), it presented lower maximum plasma concentration, faster absorption and shorter time to reach maximum concentration. When compared with the previous study in Germany, obvious variations on Tmax were found in Chinese subjects taking CAPSULE, but not TABLET. The results indicated that individual difference should be paid attention when prescribing CAPSULE to Chinese patients. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Dose {sup 131}I radioactivity interfere with thyroglobulin measurement in patients undergoing radioactive iodine therapy with recombinant human TSH?

    Energy Technology Data Exchange (ETDEWEB)

    Park, So Hyun; Bang, Ji In; Lee, Ho Young; Kim, Sang Eun [Dept. of Nuclear Medicine, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2015-06-15

    Recombinant human thyroid-stimulating hormone (rhTSH) is widely used in radioactive iodine therapy (RIT) to avoid side effects caused by hypothyroidism during the therapy. Owing to RIT with rhTSH, serum thyroglobulin (Tg) is measured with high 131I concentrations. It is of concern that the relatively high energy of 131I could interfere with Tg measurement using the immunoradiometric assay (IRMA). We investigated the effect of 131I administration on Tg measurement with IRMA after RIT. A total of 67 patients with thyroid cancer were analysed retrospectively. All patients had undergone rhTSH stimulation for RIT. The patients’ sera were sampled 2 days after 131I administration and divided into two portions: for Tg measurements on days 2 and 32 after 131I administration. The count per minute (CPM) of whole serum (200 μl) was also measured at each time point. Student’s paired t-test and Pearson’s correlation analyses were performed for statistical analysis. Serum Tg levels were significantly concordant between days 2 and 32, irrespective of the serum CPM. Subgroup analysis was performed by classification based on the 131I dose. No difference was noted between the results of the two groups. IRMA using 125I did not show interference from 131I in the serum of patients stimulated by rhTSH.

  15. Radioiodine 131 therapy in hyperthyroidism evaluation of French nuclear medicine practices

    International Nuclear Information System (INIS)

    Bernard, D.; Boin, C.; Desruet, M.; Roux, J.; Wolf, M.; Fagret, D.; Allenet, B.; Foroni, L.

    2015-01-01

    using fixed doses performed pre-therapeutic thyroid scan and uptake (98%). RAI therapy was administrated in capsule form (64%), intravenous (20%) or liquid form (16%). Conclusion: this study shows that practices about prescription of therapeutic dose of iodine-131 are heterogeneous, but the actual trend in France as in Europe, is the administration of fixed doses which are cost and time effective. Meta-analysis should be performed to clarify this debate especially about treatment outcome after fixed or calculated doses. Another point is highlighted: liquid form of 131 I is still used despite existence of substitutes (for thyroid uptake e.g. iodine-123; for the treatment e.g. iodine-131 capsule) which prevents high exposition to medical personnel and increased risk of contamination. (authors)

  16. NaiKun Offshore Wind Energy Project environmental assessment certificate[In the matter of the Environmental Assessment Act S.B.C. 2002, c 43 and in the matter of an application for an Environmental Assessment Certificate by NaiKun Wind Development Inc. for the NaiKun Offshore Wind Energy Project

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-11-15

    NaiKun Wind Development Inc. has proposed to build a 396 MW wind turbine array to connect Haida Gwaii in the Queen Charlotte Islands to British Columbia's main electricity grid via NaiKun's generation facility. The project involves the installation of 67 to 110 wind turbine generators at the project site. The project also includes an underwater cable and overland transmission line connecting to BC Hydro's grid. An environmental assessment (EA) was undertaken by British Columbia's Environmental Assessment Office (EAO) to evaluate the potential effects on marine physical environment; land use; marine aquatic ecology; visual resources; marine mammals; radio communications; marine birds; navigation; terrestrial ecology; archaeological and heritage resources; employment and economy; and public health. The EAO also assessed relevant issues raised by First Nations during the course of the EA. Upon considering the results of the EA, the BC Ministry of Energy, Mines and Petroleum Resources granted an EA certificate to NaiKun Wind Development Inc. for its proposed offshore wind energy project. The EA certificate contains many conditions that the proponent must implement throughout various stages of the project. Key commitments include undertaking a joint research project with the local crab fishery; determining the movement of sediment relative to beaches and navigation in the area; implementing an adaptive management plan for marine birds; and implementing a monitoring plan to identify any unforeseen impacts to values and recreational use of Naikoon Provincial Park. Before the project can proceed, the proponent will require provincial licenses, leases and other approvals, as well as necessary federal approvals. tabs.

  17. On-line monitoring system for I-131 manufacturing labs

    International Nuclear Information System (INIS)

    Osovizky, A.; Malamud, Y.; Paran, Y.; Tal, N.; Turgeman, S.; Weinstein, M.

    1997-01-01

    An on-line monitoring and safety system has been installed in a lab for manufacturing 1-131 capsules for nuclear medicine use. Production of up to 100mCi batches is performed in shielded glove boxes. The safety system is based on a unique, 'Medi SMARTS' system (Medical Survey Mapping Automatic Radiation Tracing System), that collects continuously the radiation measurements for processing, display, and storage for future retrieval. Radiation is measured by GM tubes, data is transferred to a data processing unit, and then via a RS-485 communication line to a computer. In addition to the operational advantages and radiation levels storage, the system is being evaluated for the purpose of identifying risky stages in the process. (authors)

  18. Posterior capsule opacification.

    Science.gov (United States)

    Wormstone, I Michael; Wang, Lixin; Liu, Christopher S C

    2009-02-01

    Posterior Capsule Opacification (PCO) is the most common complication of cataract surgery. At present the only means of treating cataract is by surgical intervention, and this initially restores high visual quality. Unfortunately, PCO develops in a significant proportion of patients to such an extent that a secondary loss of vision occurs. A modern cataract operation generates a capsular bag, which comprises a proportion of the anterior and the entire posterior capsule. The bag remains in situ, partitions the aqueous and vitreous humours, and in the majority of cases, houses an intraocular lens. The production of a capsular bag following surgery permits a free passage of light along the visual axis through the transparent intraocular lens and thin acellular posterior capsule. However, on the remaining anterior capsule, lens epithelial cells stubbornly reside despite enduring the rigours of surgical trauma. This resilient group of cells then begin to re-colonise the denuded regions of the anterior capsule, encroach onto the intraocular lens surface, occupy regions of the outer anterior capsule and most importantly of all begin to colonise the previously cell-free posterior capsule. Cells continue to divide, begin to cover the posterior capsule and can ultimately encroach on the visual axis resulting in changes to the matrix and cell organization that can give rise to light scatter. This review will describe the biological mechanisms driving PCO progression and discuss the influence of IOL design, surgical techniques and putative drug therapies in regulating the rate and severity of PCO.

  19. [Metabolic therapy with iodine 131 in patients with chronic renal failure. Clinical case].

    Science.gov (United States)

    Vázquez-Rodríguez Barbero, Inmaculada; Espadas-Maeso, María José; Muñoz-Morales, Ana; Flores-Gómez, Pilar; Serrano-Carretero, María Belén; Castedo-Sal, Juan José; Sánchez Rey-Castro, Elena; Zamorano-Córdoba, Antonio

    2015-01-01

    62 year-old male with CKD stage 5 in dialysis program since 2012 who underwent surgery for papillary thyroid carcinoma with lymph node metastasis. Subsequently, the patient was admitted to the Unit of Metabolic Therapy at his reference hospital, where he is administered 80 millicuries of iodine-131 as a treatment associated with the surgery, unable to have his conventional dialysis, nursing interventions required in various stages of implementation of the continuous extrarenal clearance techniques (TCDE) were performed. The following care values were addressed targeted to patients undergoing treatment with I(131): specific equipment, personal protective measures and major diagnoses and nursing interventions. TCDE, despite being attributed to very critical patients, they can be extrapolated to other patients in a given time. TCDE allowed these patients to undergo dialysis in a safe environment for staff, ensuring proper disposal of contaminated liquids. TCDE were an effective treatment for the removal of I131, a single ssesion being necessary to normalize the levels of radioactivity. Coordination between services allewed ensure proper and effective treatment for the patient. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  20. Wireless capsule endoscopy in adolescents with familial adenomatous polyposis.

    Science.gov (United States)

    Cavallo, Debora; Ballardini, Giovanni; Ferrari, Andrea; Delconte, Gabriele; Signoroni, Stefano; Sala, Paola; Chiaravalli, Stefano; Massimino, Maura; Bertario, Lucio; Vitellaro, Marco

    2016-01-01

    Guidelines for surveillance in patients with familial adenomatous polyposis (FAP) recommend mutation carriers to undergo periodic colorectal examination starting in the early teens. Performing colonoscopy in children may lead to complications. Wireless capsule endoscopy (WCE) has been introduced recently to evaluate both the upper and lower gastrointestinal tract, and seems suitable as a first screening examination for adolescents. The aim of this study was to evaluate the pros and cons of WCE. This was a retrospective review of a single institution database of adolescent patients with FAP identified through the Hereditary Colorectal Tumor Registry between 2007 and 2013. The main outcomes were identification of upper and lower gastrointestinal tract polyps, tolerance of the examination, and number and size of polyps. Of 46 adolescent patients with FAP, 14 (30.4%) patients carrying adenomatous polyposis coli gene (APC) mutation, 6 male and 8 female, age (median, range) 12 (10-17) years, body mass index 19 (13-24), underwent WCE as first screening examination. The examination was completed in 13 patients (93.3%). Wireless capsule endoscopy identified the duodenal papilla in 4 patients and colonic and rectal polyps in all 13 patients. In 7 patients, fewer than 25 polyps were identified. No complications were recorded related to the use of the video capsule. Wireless capsule endoscopy is feasible and well-tolerated as a first screening examination in adolescent patients. It cannot be used as alternative to the colonoscopy, but could improve compliance with colonoscopy, and increase early adherence to a surveillance program.

  1. Effects of food on a gastrically degraded drug: azithromycin fast-dissolving gelatin capsules and HPMC capsules.

    Science.gov (United States)

    Curatolo, William; Liu, Ping; Johnson, Barbara A; Hausberger, Angela; Quan, Ernest; Vendola, Thomas; Vatsaraj, Neha; Foulds, George; Vincent, John; Chandra, Richa

    2011-07-01

    Commercial azithromycin gelatin capsules (Zithromax®) are known to be bioequivalent to commercial azithromycin tablets (Zithromax®) when dosed in the fasted state. These capsules exhibit a reduced bioavailability when dosed in the fed state, while tablets do not. This gelatin capsule negative food effect was previously proposed to be due to slow and/or delayed capsule disintegration in the fed stomach, resulting in extended exposure of the drug to gastric acid, leading to degradation to des-cladinose-azithromycin (DCA). Azithromycin gelatin capsules were formulated with "superdisintegrants" to provide fast-dissolving capsules, and HPMC capsule shells were substituted for gelatin capsule shells, in an effort to eliminate the food effect. Healthy volunteers were dosed with these dosage forms under fasted and fed conditions; pharmacokinetics were evaluated. DCA pharmacokinetics were also evaluated for the HPMC capsule subjects. In vitro disintegration of azithromycin HPMC capsules in media containing food was evaluated and compared with commercial tablets and commercial gelatin capsules. When the two fast-dissolving capsule formulations were dosed to fed subjects, the azithromycin AUC was 38.9% and 52.1% lower than after fasted-state dosing. When HPMC capsules were dosed to fed subjects, the azithromycin AUC was 65.5% lower than after fasted-state dosing. For HPMC capsules, the absolute fasting-state to fed-state decrease in azithromycin AUC (on a molar basis) was similar to the increase in DCA AUC. In vitro capsule disintegration studies revealed extended disintegration times for commercial azithromycin gelatin capsules and HPMC capsules in media containing the liquid foods milk and Ensure®. Interaction of azithromycin gelatin and HPMC capsules with food results in slowed disintegration in vitro and decreased bioavailability in vivo. Concurrent measurement of serum azithromycin and the acid-degradation product DCA demonstrates that the loss of azithromycin

  2. The quick and ultrasensitive determination of K in NaI using inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Arnquist, Isaac J., E-mail: isaac.arnquist@pnnl.gov; Hoppe, Eric W.

    2017-04-11

    A highly sensitive, novel and quick assay method utilizing inductively coupled plasma mass spectrometry was developed for the determination of K in NaI powders and NaI(Tl) scintillator crystals for use in ultralow background applications. The determination of K (viz.{sup 40}K), as well as Th and U and their daughters, is important in ultralow background detector materials to ensure incorporation of materials of sufficiently high radiopurity. Through the use of improved instrumentation, cool plasma operating conditions, and meticulously clean sample preparations, detection limits of 11 fg {sup nat}K g{sup −1} (or 341 pBq {sup 40}K kg{sup −1}) was attained for K in pure water. Detection limits in the sample matrix (i.e., NaI) were 0.529 ng {sup nat}K g NaI{sup −1} (or 16.4 μBq {sup 40}K kg NaI{sup −1}). A number of different precursor NaI powder samples and NaI(Tl) scintillator crystals were assayed for their K content. Determinations ranged from 0.757 to 31.4 ng {sup nat}K g NaI{sup −1}. This method allows for the screening of materials to unprecedented levels in a fraction of the time compared to gamma ray counting techniques, providing a useful method for a more effective screening tool of K in ultralow background detector materials.

  3. The phonons brownian behaviour in NaI detectors of ionizing radiation

    International Nuclear Information System (INIS)

    Lima, Helcio Ramos de

    1996-01-01

    A theoretical study for the quadratic mean displacement of quanta of vibration waves of crystalline lattices of the cubic crystals is presented. The study is applied to the inactivated NaI detector with estimates according to the behaviour of the Einstein's equation applied to the Helium. Under the aspect of photon-phonon interaction, described by Blakemore, the chaotic behaviour of the phonons open discussion about the possibility of noises in measurements of energies near 100 KeV

  4. The puzzling interpretation of NIR indices: The case of NaI2.21

    NARCIS (Netherlands)

    Röck, B.; Vazdekis, A.; La Barbera, F.; Peletier, R. F.; Knapen, J. H.; Allende-Prieto, C.; Aguado, D. S.

    2017-01-01

    We present a detailed study of the Na I line strength index centred in the K band at 22 100 Å (NaI2.21 hereafter) relying on different samples of early-type galaxies. Consistent with previous studies, we find that the observed line strength indices cannot be fit by state-of-the-art scaled-solar

  5. Petrous bone fractures violating otic capsule.

    Science.gov (United States)

    Magliulo, Giuseppe; Ciniglio Appiani, Mario; Iannella, Giannicola; Artico, Marco

    2012-12-01

    This study presents our experience with a series of patients suffering from petrous bone fractures violating the otic capsule who underwent subtotal petrosectomy combined with eustachian tube, middle ear, and mastoid obliteration, with the goal of preventing cerebrospinal fluid (CSF) leak and meningitis. This study enrolled 26 patients between 1997 and 2011. The clinical symptoms, otoscopy, and preoperative and postoperative audiometry and facial function, as well as CSF leak or meningitis, were evaluated in each patient. The entire group underwent a subtotal petrosectomy using the technique described in detail by Fisch. In addition, each patient was interviewed using a questionnaire to evaluate the impact on quality of life. Intraoperatively, we found significant CSF leaks in 14 patients (42.5%). No patient reported other episodes of CSF leak or meningitis after the surgery. The patients' responses of facial nerve function were slightly worse than the House-Brackmann evaluation (50% versus 42.3%; p < 0.05). The vast majority (88.5%) of the patients experienced no social impact. Our findings suggest the importance of not underestimating the risk for CSF leak in the petrous bone fractures violating the otic capsule. Preoperative counseling regarding the various troublesome complications must adequately motivate candidates to undergo surgery by pointing out the positive impact of the proposed treatment.

  6. New 3D gas density maps of NaI and CaII interstellar absorption within 300 pc

    Science.gov (United States)

    Welsh, B. Y.; Lallement, R.; Vergely, J.-L.; Raimond, S.

    2010-02-01

    Aims: We present new high resolution (R > 50 000) absorption measurements of the NaI doublet (5889-5895 Å) along 482 nearby sight-lines, in addition to 807 new measurements of the CaII K (3933 Å) absorption line. We have combined these new data with previously reported measurements to produce a catalog of absorptions towards a total of 1857 early-type stars located within 800 pc of the Sun. Using these data we have determined the approximate 3-dimensional spatial distribution of neutral and partly ionized interstellar gas density within a distance-cube of 300 pc from the Sun. Methods: All newly recorded spectra were analyzed by means of a multi-component line profile-fitting program, in most cases using simultaneous fits to the line doublets. Normalized absorption profiles were fitted by varying the velocity, doppler width and column density for all intervening interstellar clouds. The resulting total column densities were then used in conjunction with the Hipparcos distances of the target stars to construct inversion maps of the 3D spatial density distribution of the NaI and CaII bearing gas. Results: A plot of the equivalent width of NaI versus distance reveals a wall of neutral gas at ~80 pc that can be associated with the boundary wall to the central rarefied Local Cavity region. In contrast, a similar plot for the equivalent width of CaII shows no sharply increasing absorption at 80 pc, but instead we observe a slowly increasing value of CaII equivalent width with increasing sight-line distance sampled. Low values for the volume density of NaI (nNaI values in the range 10-8 >nNaI > 10-10 cm-3 are found for sight-lines with distance >300 pc. Both high and low values of the volume density of CaII (nCaII) are found for sight-lines 100 pc a value of nCaII ~ 10-9 cm-3 is typical for most sight-lines, indicating that the distribution of CaII bearing gas is fairly uniform throughout the general ISM. Our three maps of the 3D spatial distribution of local neutral NaI

  7. Micronucleus induction as a measure of I-131 exposure

    Energy Technology Data Exchange (ETDEWEB)

    Kasuba, V; Horvat, D [Inst. for Medical Recearch and Occupational Health, Zagreb (Croatia). Laboratory for Mutagenesis; Kusic, Z [Clinical Hospital Sestre Milosrdnice, Zagreb (Croatia). Dept. of Oncology and Nuclear Medicine; Vlatkovic, M [Clinical Hospital Centre, Zagreb (Croatia). Dept. of Nuclear Medicine and Radiation Protection

    1994-10-01

    The change of cell numbers in the peripheral blood following irradiation has been studied for many years, particularly in patients undergoing radiotherapy. Recently, attention is directed towards the use of cytogenetic-mutagenetic methods to estimate the biological effects of received radiation dose. The aim of our study was to identify the difference in number and distribution of micronucleus, depending of applied therapeutic dose of iodine-131. According to their diagnosis, six patients have received iodine-131 in range from 80 to 140 mCi, while in the other group of patients the dose values varied from 7 to 32 mCi. On in vitro peripheral blood lymphocyte cultures micronucleus test was applied. Micronucleus analyses were carried out before the treatment, 24, 48 and 96 hours after the oral application of radiopharmaceutical. The number of micronucleus is showing increase, depending on applied radioactivity of iodine-131 and duration of exposition. The clear dose response relationship was never found. These results illustrate the problem associated with the inhomogeneous distribution of dose which results from the concentration of incorporated radionuclide into thyroid or other tissues. (author).

  8. A novel diagnostic tool for detecting functional patency of the small bowel: the Given patency capsule.

    Science.gov (United States)

    Spada, C; Spera, G; Riccioni, M; Biancone, L; Petruzziello, L; Tringali, A; Familiari, P; Marchese, M; Onder, G; Mutignani, M; Perri, V; Petruzziello, C; Pallone, F; Costamagna, G

    2005-09-01

    The current visualization of small-bowel strictures using traditional radiological methods is associated with high radiation doses and false-negative results. These methods do not always reveal small-bowel patency for solids. The aim is to assess the safety of the Given patency system and its ability to detect intestinal strictures in patients with strictures that are known or suspected radiologically. The Given patency capsule is composed of lactose, remains intact in the gastrointestinal tract for 40-100 hours post ingestion, and disintegrates thereafter. A total of 34 patients with small-bowel stricture were prospectively enrolled; 30 had a previous diagnosis of Crohn's disease, three had adhesion syndrome and in one ischemic enteritis was suspected. Of the patients, 15 (44.1 %) had previously undergone surgery. Following ingestion, the capsule was monitored for integrity and transit time, using a specially designed Given scanner and also radiologically. Seventeen patients had been enrolled with the intent of using the patency capsule as a preliminary test in patients with small-bowel strictures before undergoing video capsule endoscopy. 30 patients (88.2 %) retrieved the capsule in the stool; it was intact in 20 (median transit time 22 hours), and disintegrated in 10 patients (median transit time 53 hours). Six patients complained of abdominal pain which disappeared within 24 hours. The scanner successfully indicated the presence of the capsule in 94 % of cases. Ten patients underwent video capsule endoscopy following the patency capsule examination; in all of these the video capsule passed through the small-bowel stricture. This feasibility study has shown that the Given patency capsule is a safe, effective, and convenient tool for assessment of functional patency of the small bowel. It can indicate functional patency even in cases where traditional radiology indicates stricture.

  9. Iodine-131 monitoring in sewage plant outflow

    International Nuclear Information System (INIS)

    McGowan, D R; Crawley, M T; Pratt, B E; Hinton, P J; Peet, D J

    2014-01-01

    Three different hospital sites (Oxford, Sutton and Guildford) have performed sampling of their local sewage plant outflow to determine levels of radioactivity resulting from iodine-131 patients undergoing radionuclide therapies. It was found that a maximum of 20% of activity discharged from the hospitals was present in the sewage plant final effluent channel. This is significantly below the level predicted by mathematical models in current use. The results further show that abatement systems to reduce public exposure are unlikely to be warranted at hospital sites. (paper)

  10. Comparison of the response of a NaI scintillation crystal with a pressurized ionization chamber as a function of altitude, radiation level and Ra-226 concentration

    International Nuclear Information System (INIS)

    Provencher, R.; Smith, G.; Borak, T.B.; Kearney, P.

    1986-01-01

    The Grand Junction Uranium Mill Tailings Remedial Action-Radiological Survey Activities Group (UMTRA-RASA) program employs a screening method in which external exposure rates are used to determine if a property contaminated with uranium mill tailings is eligible for remedial action. Portable NaI detectors are used by survey technicians to locate contaminated areas and determine exposure rates. The exposure rate is calculated using a regression equation derived from paired measurements made with a pressurized ionization chamber (PIC) and a NaI detector. During July of 1985 extensive measurements were taken using a PIC and a NaI scintillator with both analogue and digital readout for a wide range of exposure rates and at a variety of elevations. The surface soil was sampled at most of these locations and analyzed for 226 Ra. The response of the NaI detectors was shown to be highly correlated to radiation level but not to 226 Ra concentration or elevation

  11. Real-time control of electronic motion: Application to NaI

    DEFF Research Database (Denmark)

    Grønager, Michael; Henriksen, Niels Engholm

    1998-01-01

    + + I- depends on the electron distribution (i.e., where the electron "sits") prior to the time where the bond is broken by a subpicosecond half-cycle unipolar electromagnetic pulse. Thus we control, in real time, which nucleus one of the valence electrons will follow after the bond is broken. (C) 1998......We study theoretically the electronic and nuclear dynamics in NaI. After a femtosecond pulse has prepared a wave packet in the first excited state, we consider the adiabatic and the nonadiabatic electronic dynamics and demonstrate explicitly that a nonstationary electron is created in Na...

  12. Measurement of neutron detection efficiencies in NaI using the Crystal Ball detector

    Energy Technology Data Exchange (ETDEWEB)

    Stanislaus, T.D.S.; Koetke, D.D. E-mail: donald.koetke@valpo.edu; Allgower, C.; Bekrenev, V.; Benslama, K.; Berger, E.; Briscoe, W.J.; Clajus, M.; Comfort, J.R.; Craig, K.; Gibson, A.; Grosnick, D.; Huber, G.M.; Isenhower, D.; Kasprzyk, T.; Knecht, N.; Koulbardis, A.; Kozlenko, N.; Kruglov, S.; Kycia, T.; Lolos, G.J.; Lopatin, I.; Manley, D.M.; Manweiler, R.; Marusic, A.; McDonald, S.; Nefkens, B.M.K.; Olmsted, J.; Papandreou, Z.; Peaslee, D.; Peterson, R.J.; Phaisangittisakul, N.; Pulver, M.; Ramirez, A.F.; Sadler, M.; Shafi, A.; Slaus, I.; Spinka, H.; Starostin, A.; Staudenmaier, H.M.; Supek, I.; Thoms, J.; Tippens, W.B

    2001-04-21

    We report on a measurement of the neutron detection efficiency in NaI crystals in the Crystal Ball (CB) detector obtained from a study of {pi}{sup -}p{yields}{pi} degree sign n reactions at the Brookhaven National Laboratory AGS. A companion GEANT-based Monte Carlo study has been done to simulate these reactions in the CB, and a comparison with the data is provided.

  13. Status of the material capsule irradiation and the development of the new capsule technology in HANARO

    International Nuclear Information System (INIS)

    Choo, Kee-Nam; Kang, Young-Hwan; Choi, Myoung-Hwan; Cho, Man-Soon; Kim, Bong-Goo

    2006-01-01

    A material capsule system including a main capsule, fixing, control, cutting, and transport systems was developed for an irradiation test of non-fissile materials in HANARO. 14 irradiation capsules (12 instrumented and 2 non-instrumented capsules) have been designed, fabricated and successfully irradiated in the HANARO CT and IR test holes since 1995. The capsules were mainly designed for an irradiation of the RPV (Reactor Pressure Vessel), reactor core materials, and Zr-based alloys. Most capsules were made for KAERI material research projects, but 5 capsules were made as a part of national projects for the promotion of the HANARO utilization for universities. Based on the accumulated irradiation experience and the user's sophisticated requirements, development of new instrumented capsule technologies for a more precise control of the irradiation temperature and fluence of a specimen irrespective of the reactor operation has been performed in HANARO. (author)

  14. Vera Poska-Grünthal - Eesti riigimehe tütar ja naisõiguslane / Kairi Ilison

    Index Scriptorium Estoniae

    Ilison, Kairi

    2010-01-01

    Riigivanema ja poliitiku Jaan Poska tütrest Vera Poska-Grünthalist (1898-1986), kes oli tuntud ajakirjanik ja naisõiguslane. Põgenes Teise maailmasõja ajal Rootsi ja asutas seal 1952. aastal ajakirja "Triinu", mis lõpetas ilmumise Torontos 1995. aastal, olles Eesti naiste ühendaja vabas maailmas

  15. Summary Report for Capsule Dry Storage Project

    Energy Technology Data Exchange (ETDEWEB)

    JOSEPHSON, W S

    2003-09-04

    There are 1.936 cesium (Cs) and strontium (Sr) capsules stored in pools at the Waste Encapsulation and Storage Facility (WESF). These capsules will be moved to dry storage on the Hanford Site as an interim measure to reduce risk. The Cs/Sr Capsule Dry Storage Project (CDSP) is conducted under the assumption the capsules will eventually be moved to the repository at Yucca Mountain, and the design criteria include requirements that will facilitate acceptance at the repository. The storage system must also permit retrieval of capsules in the event vitrification of the capsule contents is pursued. A cut away drawing of a typical cesium chloride (CsCI) capsule and the capsule property and geometry information are provided in Figure 1.1. Strontium fluoride (SrF{sub 2}) capsules are similar in design to CsCl capsules. Further details of capsule design, current state, and reference information are given later in this report and its references. Capsule production and life history is covered in WMP-16938, Capsule Characterization Report for Capsule Dry Storage Project, and is briefly summarized in Section 5.2 of this report.

  16. Analytical Model for the Probability Characteristics of a Crack Penetrating Capsules in Capsule-Based Self-Healing Cementitious Materials

    Directory of Open Access Journals (Sweden)

    Zhong LV

    2017-08-01

    Full Text Available Autonomous crack healing using pre-embedded capsules containing healing agent is becoming a promising approach to restore the strength of damaged structures. In addition to the material properties, the size and volume fraction of capsules influence crack healing in the matrix. Understanding the crack and capsule interaction is critical in the development and design of structures made of capsule-based self-healing materials. Continuing our previous study, in this contribution a more practical rupturing mode of capsules characterizing the rupturing manner of capsules fractured by cracks in cementitious materials is presented, i.e., penetrating mode. With the underlying assumption that a crack penetrating capsules undoubtedly leads to crack healing, geometrical probability theory is employed to develop the quantitative relationship between crack size and capsule size, capsule concentration in capsule-based self-healing virtual cementitious material. Moreover, an analytical expression of probability of a crack penetrating with randomly dispersed capsules is developed in two-dimensional material matrix setup. The influences of the induced rupturing modes of capsules embedded on the self-healing efficiency are analyzed. Much attention is paid to compare the penetrating probability and the hitting probability, in order to assist the designer to make a choice of the optimal rupturing modes of capsules embedded. The accuracy of results of the theoretical model is also compared with Monte-Carlo numerical analysis of crack interacting with capsules. It shows that the developed probability characteristics of a crack interaction with capsules for different rupturing modes is helpful to provide guidelines for designer working with capsule-based self-healing cementitious materials.DOI: http://dx.doi.org/10.5755/j01.ms.23.3.16888

  17. Polydopamine-coated capsules

    Science.gov (United States)

    White, Scott R.; Sottos, Nancy R.; Kang, Sen; Baginska, Marta B.

    2018-04-17

    One aspect of the invention is a polymer material comprising a capsule coated with PDA. In certain embodiments, the capsule encapsulates a functional agent. The encapsulated functional agent may be an indicating agent, healing agent, protecting agent, pharmaceutical drug, food additive, or a combination thereof.

  18. Temporal Trends in Antimicrobial Resistance and Virulence-Associated Traits within the Escherichia coli Sequence Type 131 Clonal Group and Its H30 and H30-Rx Subclones, 1968 to 2012

    DEFF Research Database (Denmark)

    Olesen, Bente; Frimodt-Møller, Jakob; Leihof, Rikke Fleron

    2014-01-01

    occurred only after 2000 and 2002, respectively, in association with the H30 and H30-Rx subclones, which were characterized by multidrug resistance (including extended-spectrum-beta-lactamase [ESBL] production: H30-Rx) and absence of biofilm production. Capsular antigen K100 occurred exclusively among H30......-Rx ST131 subclones, rather than representing acquisition of resistance by diverse ST131 strains. Distinctive characteristics of the H30-Rx subclone-including specific virulence genes (iutA, afa and dra, kpsII), the K100 capsule, multidrug resistance, and ESBL production-possibly contributed...

  19. Draft Genome Sequence of the Microbispora sp. Strain ATCC-PTA-5024, Producing the Lantibiotic NAI-107

    DEFF Research Database (Denmark)

    Sosio, M.; Gallo, G.; Pozzi, R.

    2014-01-01

    We report the draft genome sequence of Microbispora sp. strain ATCC-PTA-5024, a soil isolate that produces NAI-107, a new lantibiotic with the potential to treat life-threatening infections caused by multidrug-resistant Gram-positive pathogens. The draft genome of strain Microbispora sp. ATCC...

  20. Radiation protection recommendations for I-131 thyrotoxicosis, thyroid cancer and phaeochromocytoma patients

    International Nuclear Information System (INIS)

    Woodings, S.

    2004-01-01

    Iodine-131 patients pose a radiation risk to their family members, carers and colleagues. Doses from thyrotoxicosis and thyroid cancer patients undergoing standard treatments have been well characterised in the literature. However the resulting precautions cannot be easily adapted to circumstances where the patient has an unusual affliction, or an atypical family or occupational environment. In this study, a model for calculating dose from an I-131 patient is derived from first principles. The model is combined with existing results from the literature to determine a distance weighting factor between patients and family members. This technique reduces the uncertainty in the dose calculations by removing the need to guess the unknown patterns of close contact, a problem common to all previous dose calculation techniques. Data is presented for four unusual I-131 treatments; a child thyroid cancer patient, two thyroid cancer dialysis patients and a phaeochromocytoma patient. The model is used to calculate appropriate periods of restricted contact for these patients. The recommendations provide a useful guide for future unusual I-131 treatments. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  1. NExSS/NAI Joint ExoPAG SAG 16 Report on Remote Biosignatures for Exoplanets

    Science.gov (United States)

    Kiang, Nancy Y.; Parenteau, Mary Nicole; Domagal-Goldman, Shawn

    2017-01-01

    Future exoplanet observations will soon focus on the search for life beyond the Solar System. Exoplanet biosignatures to be sought are those with global, potentially detectable, impacts on a planet. Biosignatures occur in an environmental context in which geological, atmospheric, and stellar processes and interactions may work to enhance, suppress or mimic these biosignatures. Thus biosignature scienceis inherently interdisciplinary. Its advance is necessary to inform the design of the next flagship missions that will obtain spectra of habitable extrasolar planets. The NExSS NAI Joint Exoplanet Biosignatures Workshop Without Walls brought together the astrobiology, exoplanet, and mission concept communities to review, discuss, debate, and advance the science of remote detection of planetary biosignatures. The multi-meeting workshop began in June 2016, and was a process that engaged a broad range of experts across the interdisciplinary reaches of NASA's Nexus for Exoplanet System Science (NExSS) program, the NASA Astrobiology Institute (NAI), NASAs Exoplanet Exploration Program (ExEP), and international partners, such as the European Astrobiology Network Association (EANA) and Japans Earth Life Science Institute (ELSI). These groups spanned expertise in astronomy, planetary science, Earth sciences, heliophysics, biology, instrument mission development, and engineering.

  2. Thyroid screening of members of the public for iodine isotopes with portable NaI detectors

    International Nuclear Information System (INIS)

    Hunt, John G.

    2014-01-01

    In the case of an accident in a nuclear power plant with radionuclide releases to the environment, members of the public with possible internal contamination with radioactive isotopes of iodine should be screened to identify cases where a more detailed evaluation and medical follow-up is necessary. Screening of large numbers of the public can be performed with a quick measuring protocol using hand held unshielded NaI based detectors giving results in cps. The screening geometry was simulated using the Monte Carlo code Visual Monte Carlo. The results show that for a geometry with the NaI detector near the skin in front of the thyroid, the interference of the gamma radiation coming from other radionuclides released in the accident either deposited in the lung or in the whole body is sufficiently low to allow thyroid screening criteria to be established. The screening criteria were developed using 5, 10 and 15 year old hybrid phantoms and for the adult male based on the ICRP reference voxel phantom. (author)

  3. Hot cell examination on the surveillance capsule and HANARO capsule in IMEF

    International Nuclear Information System (INIS)

    Choo, Yong Sun; Oh, Wan Ho; Yoo, Byung Ok; Jung, Yang Hong; Ahn, Sang Bok; Baik, Seung Je; Song, Wung Sup; Hong, Kwon Pyo

    2000-01-01

    For the maintenance of integrity and safety of pressurizer of commercial power plant until its life span, it is required by US NRC 10CFR50 APP. G and H and ASTM E185-94 to periodically monitor irradiation embrittlement by neutron irradiation. In order to accomplished the requirement reactor operator has been carrying out the test by extracting the monitoring capsule embeded in reactor during the period of planned preventive maintenance. In relation to this irradiation samples are being used for prediction of reactor vessel life span and reactor vessel's adjusted reference temperature by irradiation of neutron flux enough to reach to end of life span. And also irradiation capsules with and without instrumentation are used for R and D on nuclear materials. Each capsule contains high radioactivity, therefore, post irradiation examination has to be handled by all means in the hot cell. The facility available for this purpose is Irradiated material examination facility (IMEF) to handle such works as capsule receiving, capsule cut and dismantling, sample classification, various examination, and finally development and improvement of examination equipment and instrumentation. (Hong, J. S.)

  4. Identification of transplanted pancreatic islet cells by radioactive Dithizone-[131I]-Histamine conjugate. Preliminary report

    International Nuclear Information System (INIS)

    Garnuszek, P.; Licinska, I.; Mazurek, A.P.; Mrozek, A.; Wardawa, A.; Fiedor, P.S.

    2000-01-01

    Background: The unique mechanism of dithizone action in the interior of the viable pancreatic islet suggests the possible development of a specific radiopharmaceutical that may have a potential clinical application in the diagnosis of the pancreatic organ allografts or islets rejection. The radiodiagnostic properties of the newly developed radioactive analogue of dithizone, i.e. Dithizone-[131I]-Histamine conjugate have been evaluated in the present study. METHODS: The four islet cells transplantation models were chosen for this purpose. The most important feature of the Dithizone-[131I]-Histamine conjugate is its possessed ability of zinc chelation. As was presented in the recent study, the conjugate stains pink-reddish the isolated pancreatic islets in vitro. Among the studied transplantation models, only the islets grafting under testis capsule enabled determination of the pancreatic islets in rats by radioactive Dithizone-[131I]-Histamine conjugate. The level of the radioactivity in the recipient testis (right) was almost two times higher compared to the controls (0.24 v. 0.13% ID/g, respectively). CONCLUSIONS: These preliminary data demonstrate the ability of the developed radioactive analogue of dithizone for in vivo identification of transplanted pancreatic islets, and suggests a potential clinical application of the radiodithizone in the diagnosis of the pancreatic islet rejection. (author)

  5. Lattice dynamics of NaI studied by inelastic neutron scattering: absence of thermally induced discrete breathers

    Czech Academy of Sciences Publication Activity Database

    Kempa, Martin; Ondrejkovič, Petr; Bourges, P.; Márton, Pavel; Hlinka, Jiří

    2014-01-01

    Roč. 89, č. 5 (2014), "054308-1"-"054308-5" ISSN 1098-0121 R&D Projects: GA ČR GPP204/11/P404 Institutional support: RVO:68378271 Keywords : NaI * alkali halides * inelastic neutron scattering * discrete breathers Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.736, year: 2014

  6. Passive sorting of capsules by deformability

    Science.gov (United States)

    Haener, Edgar; Juel, Anne

    We study passive sorting according to deformability of liquid-filled ovalbumin-alginate capsules. We present results for two sorting geometries: a straight channel with a half-cylindrical obstruction and a pinched flow fractioning device (PFF) adapted for use with capsules. In the half-cylinder device, the capsules deform as they encounter the obstruction, and travel around the half-cylinder. The distance from the capsule's centre of mass to the surface of the half-cylinder depends on deformability, and separation between capsules of different deformability is amplified by diverging streamlines in the channel expansion downstream of the obstruction. We show experimentally that capsules can be sorted according to deformability with their downstream position depending on capillary number only, and we establish the sensitivity of the device to experimental variability. In the PFF device, particles are compressed against a wall using a strong pinching flow. We show that capsule deformation increases with the intensity of the pinching flow, but that the downstream capsule position is not set by deformation in the device. However, when using the PFF device like a T-Junction, we achieve improved sorting resolution compared to the half-cylinder device.

  7. Magnetically guided capsule endoscopy.

    Science.gov (United States)

    Shamsudhin, Naveen; Zverev, Vladimir I; Keller, Henrik; Pane, Salvador; Egolf, Peter W; Nelson, Bradley J; Tishin, Alexander M

    2017-08-01

    Wireless capsule endoscopy (WCE) is a powerful tool for medical screening and diagnosis, where a small capsule is swallowed and moved by means of natural peristalsis and gravity through the human gastrointestinal (GI) tract. The camera-integrated capsule allows for visualization of the small intestine, a region which was previously inaccessible to classical flexible endoscopy. As a diagnostic tool, it allows to localize the sources of bleedings in the middle part of the gastrointestinal tract and to identify diseases, such as inflammatory bowel disease (Crohn's disease), polyposis syndrome, and tumors. The screening and diagnostic efficacy of the WCE, especially in the stomach region, is hampered by a variety of technical challenges like the lack of active capsular position and orientation control. Therapeutic functionality is absent in most commercial capsules, due to constraints in capsular volume and energy storage. The possibility of using body-exogenous magnetic fields to guide, orient, power, and operate the capsule and its mechanisms has led to increasing research in Magnetically Guided Capsule Endoscopy (MGCE). This work shortly reviews the history and state-of-art in WCE technology. It highlights the magnetic technologies for advancing diagnostic and therapeutic functionalities of WCE. Not restricting itself to the GI tract, the review further investigates the technological developments in magnetically guided microrobots that can navigate through the various air- and fluid-filled lumina and cavities in the body for minimally invasive medicine. © 2017 American Association of Physicists in Medicine.

  8. The evaluation of kefir pure culture starter: Liquid-core capsule entrapping microorganisms isolated from kefir grains.

    Science.gov (United States)

    Wang, Liang; Zhong, Hao; Liu, Keying; Guo, Aizhen; Qi, Xianghui; Cai, Meihong

    2016-10-01

    The main purpose of this study was to develop a pure culture starter for producing kefir. In order to accomplish starter recycling, yeasts (Kluyveromyces marxianus strain, Pichia kudriavzevii clone), lactic acid bacteria (Lactobacillus kefiri strain F4Aa, Lactobacillus kefiri strain NM131-7, Lactobacillus kefiri strain NM132-3, Lactobacillus kefiri strain NM180-3, respectively), and acetic acid bacteria (Acetobacter lovaniensis strain) were entrapped in liquid core capsules based on the distribution ratio in kefir grains. The microbiological, antimicrobial, and chemical properties of kefir made with capsules (M) and kefir grains (K) were measured and compared. According to the results of plate counts in different selective medium, the number of yeasts and bacteria in the liquid core capsules gradually increased and stabilized after eight fermentation cycles. The results of gas chromatography-mass spectrometry showed that almost all the aroma components existed in the two type of kefir, except the ethyl lactate. There was no significant difference in alcohol content, protein content, and fat content, except the acidity and sugar content. Water holding capacity of kefir K was higher than kefir M. There were 14 same free amino acids in kefir M and kefir K, and the content of most free amino acids was similar. In antimicrobial test, there was no significant difference in both kefirs. © The Author(s) 2016.

  9. Estimation of parameters biokinetics from the resolution of a model compartment for I-131. Application to a patient with thyroid carcinoma hemodialysis

    International Nuclear Information System (INIS)

    Garcia, R.; Jimenez Feltstrom, D.; Luis dimon, F. J.; Sanchez Carmona, G.; Herrador Cordoba, M.

    2013-01-01

    This work aims to define a biokinetic model for the I-131, and solve it for different conditions of the patient or person affected (normal, with cancer of the thyroid or hyperthyroid). Solve the model in the case of a patient treated with I-131 for ablation of thyroid remnants with undergoing renal insufficiency and hemodialysis . Get the parameters Biokinetic this model for different situations. (Author)

  10. Capsule Endoscopy in the Assessment of Obscure Gastrointestinal Bleeding: An Evidence-Based Analysis

    Science.gov (United States)

    2015-01-01

    established reference standard to which the diagnostic accuracy of CE can be compared. Conclusions There is very-low-quality evidence that CE has a higher sensitivity but a lower specificity than other diagnostic modalities. Capsule endoscopy has few adverse events, with capsule retention being the most serious complication. Capsule endoscopy is perceived by patients as less painful and less burdensome compared with other modalities. There is low-quality evidence that patients who undergo CE have similar rates of rebleeding, further therapeutic interventions, and hospitalization compared with other diagnostic modalities. PMID:26357529

  11. Probing cell internalisation mechanics with polymer capsules.

    Science.gov (United States)

    Chen, Xi; Cui, Jiwei; Ping, Yuan; Suma, Tomoya; Cavalieri, Francesca; Besford, Quinn A; Chen, George; Braunger, Julia A; Caruso, Frank

    2016-10-06

    We report polymer capsule-based probes for quantifying the pressure exerted by cells during capsule internalisation (P in ). Poly(methacrylic acid) (PMA) capsules with tuneable mechanical properties were fabricated through layer-by-layer assembly. The P in was quantified by correlating the cell-induced deformation with the ex situ osmotically induced deformation of the polymer capsules. Ultimately, we found that human monocyte-derived macrophage THP-1 cells exerted up to approximately 360 kPa on the capsules during internalisation.

  12. Treatment of hyperthyroidism with fixed dose form Iodine 131

    International Nuclear Information System (INIS)

    Pacheco Torres, P.; Cerquera, A.M.; Acosta, F.; Sierra, M.

    2007-01-01

    Full text: Objective: Evaluation of the response to therapy with fixed dose of Iodine-131 in patients with hyperthyroidism. One hundred seventeen patients with hyperthyroidism were tested and sent for treatment with Iodine-131. The dose of the therapy was calculated according to the pathology (Diffuser goiter (DG): Multinodular goiter (MNG) and Single toxic nodule (NST). Values of TSH confirmed hyperthyroidism by laboratory methods. The thyroid-blocking agents were discontinued: methimazole for five days and propylthiouracil two days prior to therapy. The pregnancy tests were routinely conducted in females of reproductive age group. Patients reported fasting for therapy. The doses were administered in capsule form after obtaining informed consent from the patients. The patients were normally instructed to eat only after two hours after administration of iodine to promote gastric absorption of the radionuclide. Normally a post therapy thyroid scan is performed four days after treatment. Patients are usually followed up by the endocrinologists. A three- month post therapy evaluation is done by the nuclear medicine physician by telephone. The demographic data of our patients treated are as follows: Total number of patients: 117 Female: 88 (75.21%) Male: 29 (24.79%) Age average: 45 years. Diffuse Goiter= 94 (80.34%), Multinodular Goiter= 17 (14.52%) and Toxic Adenoma (NST) = 6 (5.12%). The average administered dose was 22.5 mCi to DG, 41.8 mCi to MNG and 37.5 mCi to NST. 102 (87.14%) patients at the control at 2 years after treatment presented stable response to therapy, 15 (12.86%) required a second therapy, 11 (11.70%) with BD and 4 (23.52%) with BMN; and any patient with NST required a second therapy. 83 (88.29%) of the patients with BD; 13 (76.48%) with BMN and 6 (100%) with NST the therapy was successful. Conclusion: Fixed dose of I-131 in hyperthyroidism is useful in patients with DG (11.70%). In patients with MNG whom a fixed dose is supplied, 23.52% require a

  13. 131I Metaiodobenzylguanidine scintigraphy

    International Nuclear Information System (INIS)

    Izumi, Motomori; Morimoto, Isao; Yamashita, Shunichi; Hirayu, Hideshi; Nagataki, Shigenobu

    1988-01-01

    A newly developed radiopharmaceutical agent, 131 I-metaiodobenzylguanidine ( 131 I-MIBG) has been reported to be very useful for locating pheochromocytoma and to be specific for pheochromocytoma and safe for humans. The first 131 I-MIBG scintiscanning in Japan which has been carried out in our clinic and the analysis of clinical experience of 131 I-MIBG scanning in Japan are presented

  14. Design for measurement system of Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with the Ge detector

    International Nuclear Information System (INIS)

    Mori, Kazuteru; Uedono, Akira; Tanigawa, Shoichiro; Nakai, Katsuhiko

    1998-01-01

    The measurement system for Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with a Ge detector was developed. The principle of measurement system with the coincidence technique between the NaI detector and the Ge detector was described. Application of the system for the detection of vacancy-type defects introduced by electron irradiation in Czochralski-(Cz) grown Si was shown. Detail in the difference between the Doppler broadening profiles for Cz-Si and Si grown by the floating-zone method was also obtained. (author)

  15. Design for measurement system of Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with the Ge detector

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Kazuteru; Uedono, Akira; Tanigawa, Shoichiro [Tsukuba Univ., Ibaraki (Japan). Inst. of Materials Science; Nakai, Katsuhiko

    1998-08-01

    The measurement system for Doppler broadening profiles with the coincidence technique using a NaI detector in colinear geometry with a Ge detector was developed. The principle of measurement system with the coincidence technique between the NaI detector and the Ge detector was described. Application of the system for the detection of vacancy-type defects introduced by electron irradiation in Czochralski-(Cz) grown Si was shown. Detail in the difference between the Doppler broadening profiles for Cz-Si and Si grown by the floating-zone method was also obtained. (author)

  16. Presence of e-EDCs in surface water and effluents of pollution sources in Sai Gon and Dong Nai river basin

    Directory of Open Access Journals (Sweden)

    Tam Le Thi Minh

    2016-01-01

    Full Text Available This study aimed to assess the presence of estrogenic endocrine disrupting compounds (e-EDCs including estriol, bisphenol A (BPA, atrazine (ATZ, octylphenol, octylphenol diethoxylate, octylphenol triethoxylate, nonylphenol, Nonylphenol triethoxylate (NPE3, nonylphenol diethoxylate (NPE2 and 17β-estradiol in: (i Sai Gon and Dong Nai river waters which have been major raw water sources for drinking water supply for Ho Chi Minh City (HCMC and neighbouring provinces, and (ii water pollution sources located in their catchment basin. NPE3 and NPE2 were detected in most of the surface water samples. Concentrations of NPE3 were in a range of less than 5.9–235 ng L−1, whereas BPA was detected at significantly high concentrations in the dry season in canals in HCMC. In the upstream of Sai Gon and Dong Nai Rivers, ATZ concentrations were observed at water intake of water treatment plants served for HCMC water supply system. Similarly, high potential risk of NPE2 and NPE3 contamination at Phu Cuong Bridge near Hoa Phu water intake was identified. The significant correlation between NPE2, dissolved organic carbon and total nitrogen was found. Estrogenic equivalent or estrogenic activity of Sai Gon and Dong Nai Rivers was lower than those of the previous studies. Compared with other studies, e-EDCs of pollution in Sai Gon river basin were relatively low.

  17. Clinical studies of /sup 131/I labeled fat absorption test by the temporal counting

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, T [Kumamoto Univ. (Japan). School of Medicine

    1974-09-01

    After administration of the /sup 131/I-triolein capsule test meal, a temporal count curve was obtained. In all, 87 cases were studied of which twenty were normal and 67 were pathological. The time required to reach the highest value (TRHV) of the temporal count curve, 60% in chronic pancreatitis was more than 6 hours, while it took less than 5 hours in normal cases. In cases of intrathoracic esophagogastrostomy and hypothyroidism, TRHV was longer than the normal value. In cases of radiation therapy, TRHV was prolongated with the increase of the radiation dose. Correlation coefficient between TRHV and fecal radioactivity levels (% of dose) was investigated for each patient and was found to be significant.

  18. Status of irradiation capsule design

    International Nuclear Information System (INIS)

    Nagata, Hiroshi; Yamaura, Takayuki; Nagao, Yoshiharu

    2013-01-01

    For the irradiation test after the restart of JMTR, further precise temperature control and temperature prediction are required. In the design of irradiation capsule, particularly sophisticated irradiation temperature prediction and evaluation are urged. Under such circumstance, among the conventional design techniques of irradiation capsule, the authors reviewed the evaluation method of irradiation temperature. In addition, for the improvement of use convenience, this study examined and improved FINAS/STAR code in order to adopt the new calculation code that enables a variety of analyses. In addition, the study on the common use of the components for radiation capsule enabled the shortening of design period. After the restart, the authors will apply this improved calculation code to the design of irradiation capsule. (A.O.)

  19. Biodistribution and scintigraphy of iodine-131-iododeoxyadenosine in rats bearing breast cancer

    International Nuclear Information System (INIS)

    Kim, Seon Gu; Kim, Chang Guhn; Lee, Kang Mo

    1998-01-01

    I-131 labeled (2'-deoxy-2'-iodo-β-D-arabinofuranosyl) adenine (IAD) may be involved in DNA synthesis during active proliferation of tumor cells. We conducted this study to find out the biodistribution of IAD and it's feasibility for scintigraphic tumor imaging. Tosyl acetyl-adenosine was dissolved in acetonitrile, and I-131-NaI was added and heated to synthesize IAD. Female Fisher 344 rats inoculated with breast tumor cells were injected with 0.27 MBq of IAD. Rats were sacrificed at 0.5, 1, 2, 4, 24h and the % of injected dose per gram of tissue (%ID/g) was determined. For scintigraphy, rats bearing breast cancer were administered with 1.11 MBq of IAD and imaging was performed after 2 and 24h. Then, rat body was fixed and microtomized slice was placed on radiographic film for autoradiography. %ID/g of tumor was 0.74 (0.5h), 0.73 (1h), 0.55 (2h), 0.38 (4h), and 0.05 (24h), respectively. At 1h after injection, %ID/g of tumor was higher than that of heart (0.51). However, %ID/g of tumor was lower than blood (1.06), lung (0.77), and thyroid (177.71). At 4h, %ID/g of tumor in comparison with other tissue did not change. Tumor contrast expressed by tumor to blood ratio was 0.69 and tumor to muscle ratio was 5.11 at 1h. However, these ratios did not improve through 24h. On autoradiogram and scintigraphy at 2 and 24 hour, the tumor was well visualized. This results suggest that IAD may have a potential for tumor scintigraphy. However, further work is needed to improve localization in tumor tissue

  20. The analysis of the gamma-ray pulseheight spectra resulting from the NaI detector

    International Nuclear Information System (INIS)

    Huang Zhengde; Zhang Guishan; Chen Qun; Cao Zhong

    1990-01-01

    The analysis of the Gamma-ray pulse-height spectra resulting from NaI detector is described by using weighted least square iteration. The computer program has the function of searching for Gamma-ray peak automatically. It can be used in the analysis of continuous, discrete or their superposition spectra. Besides, there are some function of the spectrum smooth,the correction of the shift in gain and zero energy channel intercept. Some results of the computer program are presented

  1. Intrauterine fertilization capsules--a clinical trial

    DEFF Research Database (Denmark)

    Lenz, S; Lindenberg, S; Sundberg, K

    1991-01-01

    Treatment of 26 women with tubal infertility was attempted using intrauterine capsules loaded with oocytes and spermatozoa. The stimulation protocol was as used for in vitro fertilization and embryo transfer and consisted of short-term use of Buserelin, human menopausal gonadotropin, and human...... and piston from an intrauterine device. Six complete capsules and parts of two other capsules were expelled. None of the women became pregnant, compared with a pregnancy rate of 21% per aspiration following in vitro fertilization and embryo transfer during the same period....... chorionic gonadotropin. Oocytes were collected by ultrasonically guided transvaginal aspiration, and spermatozoa were prepared by swim-up technique. The gametes were placed in agar capsules 4 hr after oocyte collection, and the capsules were introduced to the uterine fundus using an insertion tube...

  2. NATIONAL FOLK MUSIC TRADITIONS IN TEODOR ZGUREANU’S CONCERTO FOR NAI (ROMANIAN PAN FLUTE AND ORCHESTRA

    Directory of Open Access Journals (Sweden)

    MUZÎCA TATIANA

    2017-06-01

    Full Text Available This article presents the first musicological analysis of Teodor Zgureanu’s concerto for nai (Romanian pan flute and orchestra. The analysis places the concerto within the context of the neofolkloric and polystylistic tradition. Its main focus is to identify the concerto’s dramatic structure and its main means of expression in relation to the modern compositional techniques.

  3. High-speed precision weighing of pharmaceutical capsules

    International Nuclear Information System (INIS)

    Bürmen, Miran; Pernuš, Franjo; Likar, Boštjan

    2009-01-01

    In this paper, we present a cost-effective method for fast and accurate in-line weighing of hard gelatin capsules based on the optimized capacitance sensor and real-time processing of the capsule capacitance profile resulting from 5000 capacitance measurements per second. First, the effect of the shape and size of the capacitive sensor on the sensitivity and stability of the measurements was investigated in order to optimize the performance of the system. The method was tested on two types of hard gelatin capsules weighing from 50 mg to 650 mg. The results showed that the capacitance profile was exceptionally well correlated with the capsule weight with the correlation coefficient exceeding 0.999. The mean precision of the measurements was in the range from 1 mg to 3 mg, depending on the size of the capsule and was significantly lower than the 5% weight tolerances usually used by the pharmaceutical industry. Therefore, the method was found feasible for weighing pharmaceutical hard gelatin capsules as long as certain conditions are met regarding the capsule fill properties and environment stability. The proposed measurement system can be calibrated by using only two or three sets of capsules with known weight. However, for most applications it is sufficient to use only empty and nominally filled capsules for calibration. Finally, a practical application of the proposed method showed that a single system is capable of weighing around 75 000 capsules per hour, while using multiple systems could easily increase the inspection rate to meet almost any requirements

  4. Thermoregulation of Capsule Production by Streptococcus pyogenes

    Science.gov (United States)

    Kang, Song Ok; Wright, Jordan O.; Tesorero, Rafael A.; Lee, Hyunwoo; Beall, Bernard; Cho, Kyu Hong

    2012-01-01

    The capsule of Streptococcus pyogenes serves as an adhesin as well as an anti-phagocytic factor by binding to CD44 on keratinocytes of the pharyngeal mucosa and the skin, the main entry sites of the pathogen. We discovered that S. pyogenes HSC5 and MGAS315 strains are further thermoregulated for capsule production at a post-transcriptional level in addition to the transcriptional regulation by the CovRS two-component regulatory system. When the transcription of the hasABC capsular biosynthetic locus was de-repressed through mutation of the covRS system, the two strains, which have been used for pathogenesis studies in the laboratory, exhibited markedly increased capsule production at sub-body temperature. Employing transposon mutagenesis, we found that CvfA, a previously identified membrane-associated endoribonuclease, is required for the thermoregulation of capsule synthesis. The mutation of the cvfA gene conferred increased capsule production regardless of temperature. However, the amount of the capsule transcript was not changed by the mutation, indicating that a post-transcriptional regulator mediates between CvfA and thermoregulated capsule production. When we tested naturally occurring invasive mucoid strains, a high percentage (11/53, 21%) of the strains exhibited thermoregulated capsule production. As expected, the mucoid phenotype of these strains at sub-body temperature was due to mutations within the chromosomal covRS genes. Capsule thermoregulation that exhibits high capsule production at lower temperatures that occur on the skin or mucosal surface potentially confers better capability of adhesion and invasion when S. pyogenes penetrates the epithelial surface. PMID:22615992

  5. Characteristics of NaI detector in positron imaging device HEADTOME employing circular ring array

    International Nuclear Information System (INIS)

    Miura, Shuichi; Kanno, Iwao; Aizawa, Yasuo; Murakami, Matsutaro; Uemura, Kazuo

    1984-01-01

    In positron emission computed tomographs employing circular ring arrays of detectors, the performance of the imaging device has been specified ultimately by the characteristics of the detector. The responses of NaI detector were studied when detecting positron annihilation photon (511 keV). The study was mainly by using the NaI detector used in hybrid emission computed tomography (CT) ''HEADTOME'' we had developed. A series of measurements were carried out positioning two detectors with 40 cm distance and scanning 22 Na point source in water. Both detectors was inclined from 0 0 through 30 0 to change incident angle of positron annihilation toward crystal face. Energy window was set from 100 to 700 keV. The results were presented as follows; 1 Shortening the crystal length from 7 to 5 cm made sensitivity decrease about 10% and resolution deteriorate about 1 mm (FWHM). 2 As the results of varying the width of the crystal, 20 mm width was optimal at any incident angle. 3 The lead septum between the detectors was the thickness of 4 mm enough to reject multiple detector interactions (crosstalk). 4 Beam mask which was made of lead in order to improve spatial resolution and placed on crystal face worked effectively for incident angles from 0 0 to 15 0 but degraded uniformity of spatial resolution from 0 0 to through 30 0 . (author)

  6. Comparison of short-term effects between interventional embolization treatment and iodine-131 therapy for graves'hyperthyroidism

    International Nuclear Information System (INIS)

    Zhu Gaohong; Zhao Wei; Yuan Weihong; Wang Bailing; Yi Gengfa; Yang Shumin

    2010-01-01

    Objective: To compare the short-term effects between interventional arterial embolization and iodine-131 therapy in treating Graves' disease. Methods: A total of 84 patients with Graves' disease (GD), confirmed by clinical data and laboratory tests, were divided into two groups: interventional group (n = 42) receiving arterial embolization and iodine-131 group (n = 42)receiving iodine-131 therapy. Before and after the treatment thyroid angiography and SPECT / CT imaging were performed to determine the shape and size of the thyroid, and radioimmunoassay method was used to measure serum levels of FT3, FT4, TSH and TRAb at 3, 6 and 12 months after the therapy. The results were compared and statistically analyzed. The occurrence of complications was observed. Results: No statistically significant difference in short-term therapeutic effects was found between interventional group and iodine-131 group. The occurrence of early severe complication was much higher in interventional group than that in iodine-131 group, while the occurrence of hypothyroidism was obviously higher in iodine-131 group than that in interventional group. Conclusion: Both interventional embolization and iodine-131 therapy have reliable effect for the treatment of Graves' disease. Iodine-131 therapy may be used in patients who plan to receive initial treatment or in patients who failed to effectively respond to other kinds of therapies, while interventional embolization may be employed in patients who are not able to receive surgery or in patients who have failed to respond to anti-thyroid drug treatment, or in patients whose iodine-131 intake rate is too low to undergo iodine-131 therapy, especially in patients with refractory and intractable hyperthyroidism. Interventional embolization can be regarded as an alternative treatment for Graves' disease. (authors)

  7. NIF capsule performance modeling

    Directory of Open Access Journals (Sweden)

    Weber S.

    2013-11-01

    Full Text Available Post-shot modeling of NIF capsule implosions was performed in order to validate our physical and numerical models. Cryogenic layered target implosions and experiments with surrogate targets produce an abundance of capsule performance data including implosion velocity, remaining ablator mass, times of peak x-ray and neutron emission, core image size, core symmetry, neutron yield, and x-ray spectra. We have attempted to match the integrated data set with capsule-only simulations by adjusting the drive and other physics parameters within expected uncertainties. The simulations include interface roughness, time-dependent symmetry, and a model of mix. We were able to match many of the measured performance parameters for a selection of shots.

  8. Herniation of the anterior lens capsule

    Directory of Open Access Journals (Sweden)

    Pereira Nolette

    2007-01-01

    Full Text Available Herniation of the anterior lens capsule is a rare abnormality in which the capsule bulges forward in the pupillary area. This herniation can be mistaken for an anterior lenticonus where both the capsule and the cortex bulge forward. The exact pathology behind this finding is still unclear. We report the clinical, ultrasound biomicroscopy (UBM and histopathological findings of a case of herniation of the anterior lens capsule. UBM helped to differentiate this entity from anterior lenticonus. Light microscopy revealed capsular splitting suggestive of capsular delamination and collection of fluid (aqueous in the area of herniation giving it a characteristic appearance.

  9. 131I Metaiodobenzylguanidine (131I MIBG) kinetics in a carcinoid tumor

    International Nuclear Information System (INIS)

    Schiavo, R.; Concolino, G.; Fazi, F.; Iannantuono, P.; Voti, S. Li; Manzara, A.; Pavoni, P.

    1987-01-01

    The 131 I-MIBG kinetics was studied in vivo in patients with carcinoid tumors and liver metastases. Activity curve analysis showed that the maximum uptake of 131 I-MIBG in a carcinoid tumor occurred after 48 hours, while its biological half time was of 8 days and a half. Although more data are necessary to understand a significant variation in 131 I-MIBG kinetics between the different kinds of APUD neoplasms, it is thought that a dynamic-funtional study allowing the evaluation of the different biological half-time, could be helpful for the selection of these neoplasms, which could be treated with 131 I-MIBG. Radiation doses required for the treatment are also estimated. (M.E.L.) [es

  10. Increasing Z-pinch vacuum hohlraum capsule coupling efficiency

    International Nuclear Information System (INIS)

    Callahan, Debbie; Vesey, Roger Alan; Cochrane, Kyle Robert; Nikroo, A.; Bennett, Guy R.; Schroen, Diana Grace; Ruggles, Laurence E.; Porter, John L.; Streit, Jon; Mehlhorn, Thomas Alan; Cuneo, Michael Edward

    2004-01-01

    Symmetric capsule implosions in the double-ended vacuum hohlraum (DEH) on Z have demonstrated convergence ratios of 14-21 for 2.15-mm plastic ablator capsules absorbing 5-7 kJ of x-rays, based on backlit images of the compressed ablator remaining at peak convergence (1). Experiments with DD-filled 3.3-mm diameter capsules designed to absorb 14 kJ of x-rays have begun as an integrated test of drive temperature and symmetry, complementary to thin-shell symmetry diagnostic capsules. These capsule implosions are characterized by excellent control of symmetry (< 3% time-integrated), but low hohlraum efficiency (< 2%). Possible methods to increase the capsule absorbed energy in the DEH include mixed-component hohlraums, large diameter foam ablator capsules, transmissive shine shields between the z-pinch and capsule, higher spoke electrode x-ray transmission, a double-sided power feed, and smaller initial radius z-pinch wire arrays. Simulations will explore the potential for each of these modifications to increase the capsule coupling efficiency for near-term experiments on Z and ZR

  11. 21 CFR 520.1660b - Oxytetracycline hydrochloride capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride capsules. 520.1660b... Oxytetracycline hydrochloride capsules. (a) Specifications. The drug is in capsule form with each capsule containing 125 or 250 milligrams of oxytetracycline hydrochloride. Oxytetracycline is the antibiotic...

  12. Thermal characteristic test for saturated temperature type capsule

    International Nuclear Information System (INIS)

    Niimi, Motoji; Someya, Hiroyuki; Kobayashi, Toshiki; Ohuchi, Mitsuo; Harayama, Yasuo

    1989-08-01

    The Japan Material Testing Reactor Project is developing a new type capsule so-called 'Saturated Temperature Capsule', as a part of irradiation technique improvement program. This type capsule, in which the water is supplied and boiled, bases on the conception of keeping the coolant at the saturated temperature and facilitating the temperature setting of specimens heated by gamma-ray in reactor. However, out-pile test was planned, because there were few usable data for design and operation of the capsule into which the coolant was injected. A out-pile apparatus, simulated the capsule with electric heaters, was fabricated and experiments were carried out, to obtain data concerning design and operation for the capsule into which the water was injected. As a structure of simulated capsule, a type of downward coolant supply was adopted. The downward coolant tube type injectes the water in the bottom of capsule by tube through the upper flange. Major objects of experiences were to grasp thermal features under operation and to provide performances of capsule control equipment. Experimental results proved that the temperature of water within the capsule was easily varied by controlling supply water flow rate, and that the control equipment was operated stably and safety. (author)

  13. Capsule safety analysis of PRTF irradiation facility

    International Nuclear Information System (INIS)

    Suwarto

    2013-01-01

    Power Ramp Test Facility (PRTF) is an irradiation facility used for fuel testing of power reactor. PRTF has a capsule which is a test fuel rod container. During operation, pressurized water of 160 bars flows through in the capsule. Due to the high pressure it should be analyzed the impact of the capsule on reactor core safety. This analysis has purpose to calculate the ability of capsule pressure capacity. The analysis was carried out by calculating pressure capacity. From the calculating results it can be concluded that the capsule with pressure capacity of 438 bars will be safe to prevent the operation pressure of PRTF. (author)

  14. Evaluation of radiophoby phenomenon among patients undergoing radioisotope therapy

    International Nuclear Information System (INIS)

    Stepien, M.; Stepien, A.; Pawlus, J.; Wasilewska-Radwanska, M.

    2005-01-01

    The aim of study was to evaluate the radiophoby symptoms among 81 patients with different type hyperthyroidism undergoing 1-131 (450-600 MBq) treatment. The state anxiety as well as the trait anxiety levels using Spielberger's scale have been evaluated. Its values were 1 - 6 points (average 3) and 3 - 7 points (average 6) respectively for state anxiety and trait one. These results indicated that radioisotope therapy causes increase of patient's anxiety level. (author)

  15. Adhesive capsulitis of the shoulder: MR arthrography

    International Nuclear Information System (INIS)

    Kim, Hyun Jeong; Han, Tae Il; Lee, Kwang Won; Choi, Youn Seon; Kim, Dae Hong; Han, Hyun Young; Song, Mun Kab; Kwon, Soon Tae

    2001-01-01

    Adhesive capsulitis is a clinical syndrome involving pain and decreased joint motion caused by thickening and contraction of the joint capsule. The purpose of this study is to describe the MR arthrographic findings of this syndrome. Twenty-nine sets of MR arthrographic images were included in the study. Fourteen patients had adhesive capsulitis diagnosed by physical examination and arthrography, and their MR arthrographic findings were compared with those of 15 subjects in the control group. The images were retrospectively reviewed with specific attention to the thickness of the joint capsule, volume of the axillary pouch (length, width, height(depth)), thinkness of the coracohumeral ligament, presence of extra-articular contrast extravasation, and contrst filling of the subcoracoid bursa. Mean capsular thickness measured at the inferior portion of the axillary pouch was 4.1 mm in patients with adhesive capsulitis and 1.5 mm in the control group. The mean width of the axillary pouch was 2.5 mm in patients and 9.5 mm in controls. In patients, the capsule was significantly thicker and the axillary pouch significantly narrower than in controls (p<0.05). Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch (sensitivity 93%, specificity 80%) and a pouch narrower than 3.5 mm (sensitivity 93%, specificity 100%) were useful criteria for the diagnosis of adhesive capsulitis. In patients with this condition, extra-articular contrast extravasation was noted in six patients (43%) and contrast filling of the subcoracoid bursa in three (21%). The MR arthrographic findings of adhesive capsulitis are capsular thickening, a low-volume axillary pouch, extra-articular contrast extravasation, and contrast filling of the subcoracoid bursa. Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch and a pouch width of less than 3.5 mm are useful diagnostic imaging characteristics

  16. Video capsule endoscopy after bariatric and gastric surgery: oral ingestion is associated with satisfactory completion rate.

    Science.gov (United States)

    Stanich, Peter P; Kleinman, Bryan; Porter, Kyle M; Meyer, Marty M

    2015-01-01

    To investigate the outcomes of video capsule endoscopy (VCE) performed on patients after bariatric and gastric surgery with a focus on delivery method (oral ingestion or endoscopic placement). There is minimal published data regarding the use of VCE in patients after bariatric and gastric surgery and the optimal delivery method is unknown. Retrospective case series of patients with bariatric or gastric surgery undergoing VCE in a tertiary care center over 3 years. Outcomes of interest were completion of the procedure and bowel transit times. Twenty-three patients met study criteria. They underwent 24 VCE in the study period, with 13/16 (81.3%; 95% CI, 54%-96%) completed to the colon after oral ingestion and 5/8 (62.5%; 95% CI, 24%-91%) completed after endoscopic deployment. The median gastric transit time after oral ingestion was 440) (P=0.48). There were no instances of capsule retention. Oral ingestion of VCE resulted in a satisfactory completion rate with rapid gastric transit after bariatric and gastric surgery. There were no capsule retention events. Given this and the favorable risk and cost profile, oral ingestion should be favored over endoscopic placement in this patient population.

  17. Methodology for calibration of detector of Nal (TI) 3 'X 3' for measurements in vivo of patients with hyperthyroidism undergoing radioiodine therapy

    International Nuclear Information System (INIS)

    Carvalho, Carlaine B.; Lacerda, Isabelle V.B.; Oliveira, Mercia L.; Hazin, Clovis A.; Lima, Fabiana F.

    2013-01-01

    The aim of this study is to establish the methodology for calibration of the detection system to be used in determining the therapeutic activity of 131 I required to release the desired absorbed dose in the thyroid. This step is critical to the development of a protocol for individualized doses. The system consists of a detector of NaI (Tl ) 3 'x3' coupled to Genie 2000 software. The calibration sources of 60 CO, 137 Cs and 133 Ba were used. Obtained straight calibration system, with 60 CO and 137 Cs sources. Subsequently, the detector was calibrated using a simulator -neck thyroid designed and produced by the IRD/CNEN with known standard solution containing 18.7 kBq 133 Ba activity (in 12/09/24) evenly distributed. He was also calibrated with other thyroid - neck phantom Model 3108 manufactured by Searle Radigraphics Ind., containing a net source of 131 I ( 7.7 MBq ). Five measurements of five minutes were realized for three different distances detector simulator, and the respective calculated calibration factors was performed to three. The values of the calibration factors found for the simulator manufactured by IRD and the Searle Radigraphics Ind. for the distances 20 , 25 and 30cm were 0.35, 0.24, 0.18, and 0.15, 0.11, 0.09, respectively. With the detection system properly calibrated and the calibration factors established, the technique is suitable for the evaluation of diagnostic activity of 131 I incorporated by hyperthyroidism

  18. Reinforcing effects of caffeine in coffee and capsules.

    Science.gov (United States)

    Griffiths, R R; Bigelow, G E; Liebson, I A

    1989-09-01

    In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee.

  19. Cost-utility analysis of antithyroid drug therapy versus 131I therapy for Graves' disease

    International Nuclear Information System (INIS)

    Hayashi, Katsumi; Abe, Katsumi; Sakata, Ikuko; Sakaguchi, Chiharu; Yamamoto, Kentaro; Kosuda, Shigeru

    2005-01-01

    There is no comparative cost-utility study between 131 I therapy and antithyroid drugs (ATD) therapy for Graves' disease, though 131 I therapy has higher remission rate and less side effects. The objective of the study was to analyze the cost-utility of ATD therapy versus 131 I therapy by calculating life-long medical costs and utility, based on the responses of Graves' disease patients to questionnaires. To determine the expected cost and expected utility, a decision tree analysis was designed on the basis of the 2 competing strategies of ATD therapy versus 131 I therapy. A simulation of 1,000 female patients weighing≥50 kg who assumed to experience the onset of Graves' disease at the age of 30, to first complain of thyrotoxic symptoms and moderate goiter 2-3 mo. previously, and to undergo a 40-years-long cohort study, was created for each strategy using a decision tree and baselines of other relevant variables. The variables and costs were based on the literature and hospital bills. The maximum and minimum values of utility were defined as 1.0 and 0.0, respectively. Future costs and utilities were discounted 5%. The medical costs and utilities were 85,739-88,650 yen/patient/40 years and 16.47-16.56/patient/40 years, respectively, for the ATD therapy strategy, and 81,842 yen/patient/40 years and 17.41/patient/40 years, respectively, for the 131 I therapy strategy. These results quantitatively demonstrated that the 131 I therapy strategy was superior to the ATD therapy strategy in terms of both cost and utility. 131 I therapy should be used more widely in Japan because of its greater utility and lower cost. (author)

  20. Measuring Pu in a glove box using portable NaI and germanium detectors

    International Nuclear Information System (INIS)

    Hankins, D.E.

    1984-01-01

    A NaI crystal or germanium detector inside a portable lead shield can determine the amount of plutonium in a glove box. The number of counts required are defined and the locations outside the box where the detector needs to be positioned are given. The calculated accuracy for measuring the Pu when these locations are used is within +/-30% for most glove boxes. Other factors that may affect this accuracy, such as γ-ray absorption by glove-box materials, self-absorption by Pu, absorption by equipment in the glove box, and the limits of the counting equipment are also discussed

  1. A New Family of Capsule Polymerases Generates Teichoic Acid-Like Capsule Polymers in Gram-Negative Pathogens.

    Science.gov (United States)

    Litschko, Christa; Oldrini, Davide; Budde, Insa; Berger, Monika; Meens, Jochen; Gerardy-Schahn, Rita; Berti, Francesco; Schubert, Mario; Fiebig, Timm

    2018-05-29

    Group 2 capsule polymers represent crucial virulence factors of Gram-negative pathogenic bacteria. They are synthesized by enzymes called capsule polymerases. In this report, we describe a new family of polymerases that combine glycosyltransferase and hexose- and polyol-phosphate transferase activity to generate complex poly(oligosaccharide phosphate) and poly(glycosylpolyol phosphate) polymers, the latter of which display similarity to wall teichoic acid (WTA), a cell wall component of Gram-positive bacteria. Using modeling and multiple-sequence alignment, we showed homology between the predicted polymerase domains and WTA type I biosynthesis enzymes, creating a link between Gram-negative and Gram-positive cell wall biosynthesis processes. The polymerases of the new family are highly abundant and found in a variety of capsule-expressing pathogens such as Neisseria meningitidis , Actinobacillus pleuropneumoniae , Haemophilus influenzae , Bibersteinia trehalosi , and Escherichia coli with both human and animal hosts. Five representative candidates were purified, their activities were confirmed using nuclear magnetic resonance (NMR) spectroscopy, and their predicted folds were validated by site-directed mutagenesis. IMPORTANCE Bacterial capsules play an important role in the interaction between a pathogen and the immune system of its host. During the last decade, capsule polymerases have become attractive tools for the production of capsule polymers applied as antigens in glycoconjugate vaccine formulations. Conventional production of glycoconjugate vaccines requires the cultivation of the pathogen and thus the highest biosafety standards, leading to tremendous costs. With regard to animal husbandry, where vaccines could avoid the extensive use of antibiotics, conventional production is not sufficiently cost-effective. In contrast, enzymatic synthesis of capsule polymers is pathogen-free and fast, offers high stereo- and regioselectivity, and works with high efficacy

  2. Methods of producing cesium-131

    Science.gov (United States)

    Meikrantz, David H; Snyder, John R

    2012-09-18

    Methods of producing cesium-131. The method comprises dissolving at least one non-irradiated barium source in water or a nitric acid solution to produce a barium target solution. The barium target solution is irradiated with neutron radiation to produce cesium-131, which is removed from the barium target solution. The cesium-131 is complexed with a calixarene compound to separate the cesium-131 from the barium target solution. A liquid:liquid extraction device or extraction column is used to separate the cesium-131 from the barium target solution.

  3. Oxygen fugacity and piston cylinder capsule assemblies

    Science.gov (United States)

    Jakobsson, S.

    2011-12-01

    A double capsule assembly designed to control oxygen fugacity in piston cylinder experiments has been tested at 1200 °C and 10 kbar. The assembly consists of an outer Pt-capsule containing a solid buffer (Ni-NiO or Co-CoO plus H2O) and an inner AuPd-capsule containing the sample, H2O and a Pt-wire. To prevent direct contact with the buffer phases the AuPd-capsule is embedded in finely ground Al2O3 along with some coarser, fractured Al2O3 facilitating fluid inclusion formation. No water loss is observed in the sample even after 48 hrs but a slight increase in water content is observed in longer duration runs due to oxygen and hydrogen diffusion into the AuPd-capsule. Carbon from the furnace also diffuses through the outer Pt-capsule but reacts with H2O in the outer capsule to form CO2 and never reaches the inner capsule. Oxygen fugacity of runs in equilibrium with the Ni-NiO and Co-CoO buffers was measured by analyzing the Fe content of the Pt-wire in the sample1 and by analyzing Fe dissolved in the AuPd capsule2. The second method gives values that are in good agreement with established buffer whereas results from the first method are one half to one log units higher than the established values. References 1. E. Medard, C. A. McCammon, J. A. Barr, T. L. Grove, Am. Mineral. 93, 1838 (2008). 2. J. Barr, T. Grove, Contrib. Mineral. Petrol. 160, 631 (2010)

  4. Development of out-of-pile version of instrumented irradiation capsule for determination of online creep deformation

    International Nuclear Information System (INIS)

    Venkatesu, Sadu; Saxena, Rajesh; Chaurasia, P.K.; Muthuganesh, M.; Murugan, S.; Venugopal, S.

    2016-01-01

    Materials used for fuel cladding and structural components in fast reactors can undergo significant dimensional and physical changes due to exposure to high energy neutrons. At high temperatures in nuclear environment, material undergoes considerable deformation due to thermal and irradiation creep. Diametral increase of fuel pin due to thermal and irradiation creep, apart from irradiation swelling, reduces the coolant flow area around the fuel pins affecting the effective removal of heat generated in the fuel pins. The changes due to creep can be determined by two types of material irradiation tests in reactor. The first type includes non-instrumented irradiation tests with specimen dimensional evaluations carried out in post-irradiation examinations. The second type includes instrumented irradiation tests with online monitoring and/or controlling of test conditions and real time measurement of changes in dimensions of the specimen. During instrumented irradiation tests, parameters such as specimen temperature, the load exerted on the specimen, specimen elongation, etc. can be monitored and/or controlled using suitable components such as linear variable differential transformers (LVDTs), bellows, thermocouples, etc. Instrumented irradiation experiments in reactors are relatively complex in design but can provide full information on the experimental parameters. Such benefits provide motivation for development of instrumented irradiation capsule to measure creep behavior online during in-pile instrumented irradiation tests. Out-of-pile version of the instrumented irradiation capsule for determination of online creep deformation has been developed and tested in the furnace by raising the temperature gradually up to 330 °C. This paper discusses the details of the design, assembly of experimental set up and experimental results of the out-of-pile version of instrumented capsule developed in our laboratory for determination of online creep deformation. (author)

  5. Vortex rings from Sphagnum moss capsules

    Science.gov (United States)

    Whitaker, Dwight; Strassman, Sam; Cha, Jung; Chang, Emily; Guo, Xinyi; Edwards, Joan

    2010-11-01

    The capsules of Sphagnum moss use vortex rings to disperse spores to suitable habitats many kilometers away. Vortex rings are created by the sudden release of pressurized air when the capsule ruptures, and are an efficient way to carry the small spores with low terminal velocities to heights where they can be carried by turbulent wind currents. We will present our computational model of these explosions, which are carried out using a 2-D large eddy simulation (LES) on FLUENT. Our simulations can reproduce the observed motion of the spore clouds observed from moss capsules with high-speed videos, and we will discuss the roles of bursting pressure, cap mass, and capsule morphology on the formation and quality of vortex rings created by this plant.

  6. [Evaluation of nopal capsules in diabetes mellitus].

    Science.gov (United States)

    Frati Munari, A C; Vera Lastra, O; Ariza Andraca, C R

    1992-01-01

    To find out if commercial capsules with dried nopal (prickle-pear cactus, Opuntia ficus indica may have a role in the management of diabetes mellitus, three experiments were performed: 30 capsules where given in fasting condition to 10 diabetic subjects and serum glucose was measured through out 3 hours; a control test was performed with 30 placebo capsules. OGTT with previous intake of 30 nopal or placebo capsules was performed in ten healthy individuals. In a crossover and single blinded study 14 diabetic patients withdrew the oral hypoglycemic treatment and received 10 nopal or placebo capsules t.i.d. during one week; serum glucose, cholesterol and tryglycerides levels were measured before and after each one-week period. Five healthy subjects were also studied in the same fashion. Opuntia capsules did not show acute hypoglycemic effect and did not influence OGTT. In diabetic patients serum glucose, cholesterol and tryglycerides levels did not change with Opuntia, but they increased with placebo (P nopal, while cholesterol and triglycerides decreased (P < 0.01 vs. placebo). The intake of 30 Opuntia capsules daily in patients with diabetes mellitus had a discrete beneficial effect on glucose and cholesterol. However this dose is unpractical and at present it is not recommended in the management of diabetes mellitus.

  7. Design and fabrication of non-instrumented capsule

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Sung; Lee, Jeong Young; Kim, Joon Yeon; Lee, Sung Ho; Ji, Dae Young; Kim, Suk Hoon; Ahn, Sung Ho [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-04-01

    The use of non-instrumented capsule designed and fabricated in this time is for the evaluation of material irradiation performance, it is to be installed in the inner core of HANARO. The design process of non-instrumented capsule was accomplished by the decision of the quality of material and the shape, thermal analysis, structural analysis. The temperature of the specimen and the stress in capsule during irradiation test was calculated by the thermal analysis and the structural analysis. GGENGTC code and ABAQUS code were used for the calculation of non-instrumented capsule. In case of installing the capsule in irradiation hole, the coolant flow rate and the pressure drop in the hole is changed, which will affect the coolant flow rate of the fuel region. Eventually the coolant flow rate outside capsule have to be restricted to the allowable range. In order to obtain the required pressure drop, the flow rate control mechanism, end plate and orifice ring were used in this test. The test results are compared with 36-element fuel pressure drop data which AECL performed by the SCTR facility.

  8. Design and fabrication of non-instrumented capsule

    International Nuclear Information System (INIS)

    Kim, Yong Sung; Lee, Jeong Young; Kim, Joon Yeon; Lee, Sung Ho; Ji, Dae Young; Kim, Suk Hoon; Ahn, Sung Ho

    1995-04-01

    The use of non-instrumented capsule designed and fabricated in this time is for the evaluation of material irradiation performance, it is to be installed in the inner core of HANARO. The design process of non-instrumented capsule was accomplished by the decision of the quality of material and the shape, thermal analysis, structural analysis. The temperature of the specimen and the stress in capsule during irradiation test was calculated by the thermal analysis and the structural analysis. GGENGTC code and ABAQUS code were used for the calculation of non-instrumented capsule. In case of installing the capsule in irradiation hole, the coolant flow rate and the pressure drop in the hole is changed, which will affect the coolant flow rate of the fuel region. Eventually the coolant flow rate outside capsule have to be restricted to the allowable range. In order to obtain the required pressure drop, the flow rate control mechanism, end plate and orifice ring were used in this test. The test results are compared with 36-element fuel pressure drop data which AECL performed by the SCTR facility

  9. Clinical study of radioisotope uptake mechanisms in 33 brain lesions by comparative use of Na131I and SAIR

    International Nuclear Information System (INIS)

    Gonsette, R.E.; Claeys, L.

    1975-01-01

    It is suggested that an isotope of small molecular size, not bound to proteins (NaI), would pass more easily into little-differentiated tumours and vascular syndromes due chiefly to a lesion of the hematoencephalic barrier (HEB). On the other hand iodinated serumalbumine (SAIR), a large organic molecule accumulating in abnormal extracellular spaces, should in principle be a better indicator in non-primitive tumours and highly differentiated tumours of the SNC. The clinical study reported confirms this hypothesis. Non-primitive tumours, meningiomas, metastases, sarcomas, are shown more clearly by SAIR (especially in meningiomas, nearly 90% of cases). In non-primitive tumours the difference in behaviour between NaI and SAIR does seem to depend on the degree of differentiation of the tumour. Thus in so-called benign gliomas the NaI uptake is greater, whereas in highly differentiated gliomas the advantage goes to SAIR. In one case of circulation deficiency a vascular type of hyperfixation was observed with NaI, while SAIR showed practically nothing [fr

  10. Thick tumor capsule is a valuable risk factor for distant metastasis in follicular thyroid carcinoma.

    Science.gov (United States)

    Shimbashi, Wataru; Sugitani, Iwao; Kawabata, Kazuyoshi; Mitani, Hiroki; Toda, Kazuhisa; Yamada, Keiko; Sato, Yukiko

    2018-02-01

    While the biological behavior of follicular thyroid carcinoma (FTC) has been studied in great detail using clinical experience, few studies have investigated pre- or intraoperative factors related to the risk of distant metastasis (DM) among patients with FTC. The aim of this study was to analyze the characteristics of FTC with DM. This study retrospectively investigated 102 patients with FTC who underwent surgery between 1988 and 2013. We compared clinicopathological characteristics between FTC with and without DM. Univariate analysis revealed nodal metastasis (p=0.045), serum thyroglobulin (Tg) at initial operation (≥1000ng/ml; pthick tumor capsule (≥1mm; pthick tumor capsule (≥1mm), serum Tg at initial operation (≥1000ng/ml), and macroscopically widely invasive appearance as risk factors independently associated with development of DM. Patients with these risk factors should undergo total thyroidectomy and radioactive iodine ablation. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Predicting corrosion of 316L stainless steel capsule by low level radioactive wastes (Am-241 and Co-60) in underground repository

    International Nuclear Information System (INIS)

    Nunoo, R.

    2013-07-01

    Most of radioactive wastes in Ghana are of low level in activity, (i.e LLRW) and are currently kept under lock in a secured room. The proposed plan by the Ghana Atomic Energy Commission is to seal the LLRW In 316L stainless steel disposal capsule for borehole repository. The research presented in this thesis was aimed at predicting the rate of both uniform and pitting corrosion of the 316L stainless steel disposal capsule by LLRW that will be kept in the capsule as a function of temperature, PH and chloride concentration for a period of up to 1000 years of disposal. The prediction analysis was based on the point defect deterministic model which assumed Schottky defects as the defect of the oxide formed on the surfaces of the disposal capsule. Faradays law and Fick first law of diffusion were used to determine the current across the internal and external surfaces of the capsule used to predict the uniform corrosion rate and corrosion loss of the 316L stainless steel disposal capsule. By imposing chlorine on the external environment of the disposal capsule, pit growth rate and pit depth of capsule were also predicted over a period of 1000 years. The capsule containing disused Am-241 source at activity level of 1.67×10 3 Bq had an average uniform corrosion rate of 3.65×10 -7 m/year and average pit growth rate of 1.79×10 -6 m/year while the corrosion rate and pit growth rate of the capsule containing disused Co-60 with activity level of 2.78×10 8 Bq were 6.9×10 -7 m/year and 2.1×10 -6 m/year respectively at PH value of 8 and repository temperature of 75°C and chloride concentration of 0.5 M. The uniform corrosion rate indicated that at PH=8 and T=75°C, 80.04% of the disposal capsule containing disused Am-241 would remain whiles 62.34% of that containing Co-60 disused source would remain after 1000 years when undergoing uniform corrosion, and an arbitrary position on the disposal capsule will have a pit depth of 1.98×10 -3 m after 100 years. Hence the integrity

  12. Capsule endoscopy—A mechatronics perspective

    Science.gov (United States)

    Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay

    2011-03-01

    The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.

  13. Isolation of Capsulate Bacteria from Acute Dentoalveolar Abscesses

    OpenAIRE

    Lewis, M. A. O.; Milligan, S. G.; MacFarlane, T. W.; Carmichael, F. A.

    2011-01-01

    The presence of a capsule was determined for 198 bacterial strains (57 facultative anaerobes, 141 strict anaerobes) isobdted from pus samples aspirated from 40 acute dentoalveolar abscesses. A total of 133 (67 per cent) of the isolates (42 facultative anaerobes, 91 strict anaerobes) were found to have a capsule. Possession ofa capsule may in part explain the apparent pathogenicity of the bacterial species encountered in acute dentoalveolar abscess.Keywords - Bacterial capsule; Acute dentoalve...

  14. Quality control procedures for iodinated radiopharmaceuticals 131I-Hippuran and 131I-Risa

    International Nuclear Information System (INIS)

    Toledo e Souza, I.T. de; Pereira, N.P.S. de; Silva, C.P.G. da.

    1986-02-01

    A rapid miniaturized chromatography system was developed for fast determination of the proportion of inorganic radioactive iodide from radiopharmaceutical 131 I-Hippuran and 131 I-Risa. The technical parameters associated with miniaturized chromatography system were evaluated. One of the problems found in this system was the movement of the 131 I-Risa from the origin with consequent overestimation of the inorganic iodide. A correct spot placement eliminated this problem. (Author) [pt

  15. Capsule Endoscopy

    Science.gov (United States)

    ... because experience with it is limited and traditional upper endoscopy is widely available. Why it's done Your doctor might recommend a capsule endoscopy procedure to: Find the cause of gastrointestinal bleeding. If you have unexplained bleeding in your digestive ...

  16. Capsule development and utilization for material irradiation tests

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Kim, B G; Joo, K N [and others

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules.

  17. Capsule development and utilization for material irradiation tests

    International Nuclear Information System (INIS)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N.

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules

  18. 46 CFR 45.131 - Ventilators.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Ventilators. 45.131 Section 45.131 Shipping COAST GUARD....131 Ventilators. (a) Ventilators passing through superstructures other than enclosed superstructures must have coamings of steel or equivalent material at the freeboard deck. (b) Ventilators in position 1...

  19. Adsorption and desorption of phosphorus in ceramic capsules

    International Nuclear Information System (INIS)

    Almeida, J.R.F. de.

    1983-01-01

    Experiments were carried out in order to analyse the capacity of adsorving P from water using ceramic capsules with 32P, in the presence and absence of water flow through the capsule. Also studied was the desorption of 32 P from the capsule in water, with and without water flow. The desorption of residual 32 P was analysed by isotopic exchange with 31 P, also with and without water flow. It was observed that, in the presence of a flow, the capsule retained 32 P from the solution, which was weakly desorbed by water but was isotopically exchanged with 31 P. In the absence of a flow, the capsule was not an efficient P adsorber. (Author) [pt

  20. Production, deformation and mechanical investigation of magnetic alginate capsules

    Science.gov (United States)

    Zwar, Elena; Kemna, Andre; Richter, Lena; Degen, Patrick; Rehage, Heinz

    2018-02-01

    In this article we investigated the deformation of alginate capsules in magnetic fields. The sensitivity to magnetic forces was realised by encapsulating an oil in water emulsion, where the oil droplets contained dispersed magnetic nanoparticles. We solved calcium ions in the aqueous emulsion phase, which act as crosslinking compounds for forming thin layers of alginate membranes. This encapsulating technique allows the production of flexible capsules with an emulsion as the capsule core. It is important to mention that the magnetic nanoparticles were stable and dispersed throughout the complete process, which is an important difference to most magnetic alginate-based materials. In a series of experiments, we used spinning drop techniques, capsule squeezing experiments and interfacial shear rheology in order to determine the surface Young moduli, the surface Poisson ratios and the surface shear moduli of the magnetically sensitive alginate capsules. In additional experiments, we analysed the capsule deformation in magnetic fields. In spinning drop and capsule squeezing experiments, water droplets were pressed out of the capsules at elevated values of the mechanical load. This phenomenon might be used for the mechanically triggered release of water-soluble ingredients. After drying the emulsion-filled capsules, we produced capsules, which only contained a homogeneous oil phase with stable suspended magnetic nanoparticles (organic ferrofluid). In the dried state, the thin alginate membranes of these particles were rather rigid. These dehydrated capsules could be stored at ambient conditions for several months without changing their properties. After exposure to water, the alginate membranes rehydrated and became flexible and deformable again. During this swelling process, water diffused back in the capsule. This long-term stability and rehydration offers a great spectrum of different applications as sensors, soft actuators, artificial muscles or drug delivery systems.

  1. Capsule endoscopy: Beyond small bowel

    Directory of Open Access Journals (Sweden)

    Samuel N Adler

    2012-01-01

    Full Text Available In this article the brief and dramatic history of capsule endoscopy of the digestive tract is reviewed. Capsule endoscopy offers a non invasive method to diagnose diseases that affect the esophagus, small bowel and colon. Technological improvements relating to optics, software, data recorders with two way communication have revolutionized this field. These advancements have produced better diagnostic performance.

  2. Synthesis of (131)I-labeled-[(131)I]iodo-17-allylamino-17-demethoxy geldanamycin ([(131)I]iodo-17-AAG) and its biodistribution in mice.

    Science.gov (United States)

    Daozhen, Chen; Lu, Liu; Min, Yang; Xinyu, Jiang; Ying, Huang

    2007-10-01

    The aim of this study was to examine the radioiodinating condition of 17-allylamino-17-demethoxy geldanamycin (17-AAG) and observe its biodistribution in the hepatoma cell line HepA tumorearing ICR mice for understanding the possibility of its application in nuclear medicine. [(131)I]iodo-17-AAG was prepared by the reaction of 17-AAG with Na[(131)I] in the presence of hydrogen peroxide. [(131)I]iodo-17-AAG was purified by high-performance liquid chromatography (HPLC). The stability of [(131)I]iodo-17-AAG was measured by thin-layer chromatography (TLC). The distributions in HepA tumor-bearing ICR mice at 0.5, 1, 4, 8, 24, and 48 hours after injection of [(131)I]iodo-17-AAG were measured. Tumor uptake studies were performed in HepA tumor-bearing ICR mice. The labeling yield was over 83%. The radiochemical purity of [(131)I]iodo-17-AAG was 99.6% after purification. The specific activity was greater than 4 Ci/micromol. The labeled compound was stable for at least 120 hours in saline at 4 degrees C. It was initially in blood at 5 minutes with 4.79% of injected dose per g of tissue (%ID/g), and then dropped 0.33% ID/g at 24 hours. The uptake in liver, lung, and kidney at 4.44% ID/g, 2.03% ID/g, and 2.17% ID/g decreased with time, and less than 1% ID/g was measured after 24 hours in those organs. There was rapid tumor uptake, which reached 1.26% ID/g at 0.5 hours, the highest uptake at 8 hours. Yet, the [(131)I]iodo-17-AAG in the contralateral muscle was at a low level during the 48 hours. The tumor-contralateral muscle (T/CM) radioactivity ratio for [(131)I]iodo-17-AAG remained constant at all time points. [(131)I]iodo-17-AAG can be efficiently radiolabeled at high specific activity, purified by HPLC and stored with little radiolysis at this specific activities. [(131)I]iodo-17-AAG is a promising radiopharmaceutical in nuclear medicine, especially for tumor-targeted radionuclide brachytherapy.

  3. Model of iodine metabolism in a T3-thyrotoxic patient undergoing I-131 therapy

    International Nuclear Information System (INIS)

    Ahuja, S.; Price, R.; Brill, A.B.; Dobyns, B.M.; Berman, M.

    Data on radioactivity in the thyroid, urine, serum, butanol-extractable iodine (BEI) and chromatographic fractionations of BEI, obtained during four I-131 therapeutic treatments of a T 3 -thyrotoxic patient, have been analyzed and simulated with the help of a 7-compartment model. Good fits to most of the data can be obtained with both the dose-independent and dose-dependent models. A model with 3 or 4 compartments, which provides adequate fits to iodine kinetic data in most euthyroid and hyperthyroid patients is not satisfactory in the case of this patient. Thus, to represent iodine metabolism during T 3 -thyrotoxicosis therapy, we find that it is necessary to provide for separate biochemical pathways for the BEI components as well as the butanol-insoluble compounds released by the thyroid gland

  4. Applicability of a portable CdTe and NaI (Tl) spectrometer for activity measure

    International Nuclear Information System (INIS)

    Fernandes, Jaquiel Salvi

    2005-02-01

    In this work it was studied the application of an in situ gamma spectrometer (ROVER) of Amptek Inc., composed by a Cadmium Telluride detector (CdTe) of 3 mm x 3 mm x 1 mm and a 30 mm x 30 mm Sodium Iodide detector doped with Thallium [NaI (Tl)). The radioactive sources used were type pastille, sealed in aluminum and polyethylene, of 241 Am, 133 Ba, 152 Eu, 3 sources of 137 Cs and soil samples contaminated with 137 Cs. It was performed a factorial planning 2 3 to optimize the in situ spectrometry system. This way it was determined that the best temperature for CdTe crystal operation is -22, deg C, with Shaping Time of 3 μS and Rise Time Discrimination (RTD) with value 3. With the help of the certified radioactive sources, we determined the efficiency curve of the two detectors. The CdTe detector was positioned at the standard distance of 1 meter of the sources and also at 4.15 cm. The NaI (Tl) detector was also positioned at the standard distance of 1 meter of the sources and at 2.8 cm. Measures were performed to determine the Minimum Detectable Activity (MDA) for both detectors. For the pastille type sources, the 137 Cs MDA for the CdTe detector at 4.15 cm, analyzing the energy line of 32 keV, was 6 kBq and at 1 meter of the 137 Cs source, analyzing the line of 661.65 keV, the MDA was 67 kBq. For soil samples, CdTe detector at 4.15 cm presented a MDA of 693 kBq.kg-l for the line of 32 keV, and for the soil sample 7 Be content the MDA found was 2867 Bq.kg -1 at 4.15 cm. For the NaI (Tl) detector, analyzing the line of 661.65 keV, the 137 Cs MDA for pastille type source at 1 meter of distance was 7 kBq, and for soil sample at 2.8 cm the measured 137 Cs MDA was 71 Bq.kg -1 . For the soil sample 7 Be content, at 2.8 cm of the Nal (Tl) detector, the obtained MDA was 91 Bq.kg -1 . Due to the minimum detectable activities found for the two detectors, we concluded that the employed in situ gamma ray spectrometer system allows the quantification of 137 Cs and 7 Be

  5. Capsule development and utilization for material irradiation tests

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N. [and others

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules.

  6. 21 CFR 131.110 - Milk.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Milk. 131.110 Section 131.110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION MILK AND CREAM Requirements for Specific Standardized Milk and Cream § 131.110 Milk. (a...

  7. 49 CFR 237.131 - Design.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Design. 237.131 Section 237.131 Transportation... TRANSPORTATION BRIDGE SAFETY STANDARDS Repair and Modification of Bridges § 237.131 Design. Each repair or... component of a bridge shall be designed by a railroad bridge engineer. The design shall specify the manner...

  8. Motion of an elastic capsule in a square microfluidic channel.

    Science.gov (United States)

    Kuriakose, S; Dimitrakopoulos, P

    2011-07-01

    In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e., small, moderate, and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross section in the upstream portion of large capsules is nonaxisymmetric (i.e., square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a(-2) for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux-U ~ h ~ a(-2

  9. Development of remote welding techniques for in-pile IASCC capsules and evaluation of material integrity on capsules for long irradiation period

    Science.gov (United States)

    Shibata, A.; Nakano, J.; Ohmi, M.; Kawamata, K.; Nakagawa, T.; Tsukada, T.

    2012-03-01

    To simulate irradiation assisted stress corrosion cracking (IASCC) behavior by in-pile experiments, it is necessary to irradiate specimens up to a neutron fluence that is higher than the IASCC threshold fluence. Pre-irradiated specimens must be relocated from pre-irradiation capsules to in-pile capsules. Hence, a remote welding machine has been developed. And the integrity of capsule housing for a long term irradiation was evaluated by tensile tests in air and slow strain rate tests in water. Two type specimens were prepared. Specimens were obtained from the outer tubes of capsule irradiated to 1.0-3.9 × 1026 n/m2 (E > 1 MeV). And specimens were irradiated in a leaky capsule to 0.03-1.0 × 1026 n/m2. Elongation more than 15% in tensile test at 423 K was confirmed and no IGSCC fraction was shown in SSRT at 423 K which was estimated as temperature at the outer tubes of the capsule under irradiation.

  10. Development of remote welding techniques for in-pile IASCC capsules and evaluation of material integrity on capsules for long irradiation period

    International Nuclear Information System (INIS)

    Shibata, A.; Nakano, J.; Ohmi, M.; Kawamata, K.; Nakagawa, T.; Tsukada, T.

    2012-01-01

    To simulate irradiation assisted stress corrosion cracking (IASCC) behavior by in-pile experiments, it is necessary to irradiate specimens up to a neutron fluence that is higher than the IASCC threshold fluence. Pre-irradiated specimens must be relocated from pre-irradiation capsules to in-pile capsules. Hence, a remote welding machine has been developed. And the integrity of capsule housing for a long term irradiation was evaluated by tensile tests in air and slow strain rate tests in water. Two type specimens were prepared. Specimens were obtained from the outer tubes of capsule irradiated to 1.0–3.9 × 10 26 n/m 2 (E > 1 MeV). And specimens were irradiated in a leaky capsule to 0.03–1.0 × 10 26 n/m 2 . Elongation more than 15% in tensile test at 423 K was confirmed and no IGSCC fraction was shown in SSRT at 423 K which was estimated as temperature at the outer tubes of the capsule under irradiation.

  11. Polar tent for reduced perturbation of NIF ignition capsules

    Science.gov (United States)

    Hammel, B. A.; Pickworth, L.; Stadermann, M.; Field, J.; Robey, H.; Scott, H. A.; Smalyuk, V.

    2016-10-01

    In simulations, a tent that contacts the capsule near the poles and departs tangential to the capsule surface greatly reduces the capsule perturbation, and the resulting mass injected into the hot-spot, compared to current capsule support methods. Target fabrication appears feasible with a layered tent (43-nm polyimide + 8-nm C) for increased stiffness. We are planning quantitative measurements of the resulting shell- ρR perturbation near peak implosion velocity (PV) using enhanced self-emission backlighting, achieved by adding 1% Ar to the capsule fill in Symcaps (4He + H). Layered DT implosions are also planned for an integrated test of capsule performance. We will describe the design and simulation predictions. Prepared by LLNL under Contract DE-AC52-07NA27344.

  12. 21 CFR 131.200 - Yogurt.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Yogurt. 131.200 Section 131.200 Food and Drugs... CONSUMPTION MILK AND CREAM Requirements for Specific Standardized Milk and Cream § 131.200 Yogurt. (a) Description. Yogurt is the food produced by culturing one or more of the optional dairy ingredients specified...

  13. Diagnostic and therapeutic capsules and method of producing

    International Nuclear Information System (INIS)

    Morcos, N.A.; Haney, T.A.; Wedeking, P.W.

    1981-01-01

    An article of manufacture comprising a pharmaceutical radioactive capsule formed essentially of a non-toxic, water soluble material adapted to being ingested and rapidly disintegrating on contract with fluids of the gastro-intestinal tract, and having a filler material supporting a pharmaceutically useful radioactive compound absorbable from the gastro-intestinal tract said filler material being supported by said capsule. And a method of filling a pharmaceutical radioactive capsule comprising providing filler material supporting a pharmaceutically useful radioactive compound and transporting said filler material carrying a pharmaceutically useful radioactive compound into the chamber of said capsule

  14. Evidence for an intact polysaccharide capsule in Bordetella pertussis.

    Science.gov (United States)

    Neo, YiLin; Li, Rui; Howe, Josephine; Hoo, Regina; Pant, Aakanksha; Ho, SiYing; Alonso, Sylvie

    2010-03-01

    Polysaccharide capsules contribute to the pathogenesis of many bacteria species by providing resistance against various defense mechanisms. The production of a capsule in Bordetella pertussis, the etiologic agent of whooping cough, has remained controversial; earlier studies reported this pathogen as a capsulated microorganism whereas the recent B. pertussis genome analysis revealed the presence of a truncated capsule locus. In this work, using transmission electron microscopy and immunostaining approaches, we provide a formal evidence for the presence of an intact microcapsule produced at the surface of both laboratory strain and clinical isolates of B. pertussis. In agreement with previous studies, we found that the capsule is optimally produced in avirulent phase. Unexpectedly, the presence of the capsule was also detected at the surface of virulent B. pertussis bacteria. Consistently, a substantial transcriptional activity of the capsule operon was detected in virulent phase, suggesting that the capsular polysaccharide may play a role during pertussis pathogenesis. In vitro assays indicated that the presence of the capsule does not affect B. pertussis adherence to mammalian cells and does not further protect the bacterium from phagocytosis, complement-mediated killing or antimicrobial peptide attack. Copyright 2009. Published by Elsevier SAS.

  15. Endurance test for DUPIC capsule

    International Nuclear Information System (INIS)

    Chung, Heung June; Bae, K. K.; Lee, C. Y.; Park, J. M.; Ryu, J. S.

    1999-07-01

    This report presents the pressure drop, vibration and endurance test results for mini-plate fuel rig which were designed fabricately by KAERI. From the pressure drop test results, it is noted that the flow rate across the capsule corresponding to the pressure drop of 200 kPa is measured to be about 9.632 kg/sec. Vibration frequency for the capsule ranges from 14 to 18.5 Hz. RMS (Root Mean Square) displacement for the fuel rig is less than 14 μm, and the maximum displacement is less than 54 μm. Based on the endurance test results, the appreciable fretting wear for the DUPIC capsule was not detected. Oxidation on the support tube is observed, also tiny trace of wear between contact points observed. (author). 4 refs., 10 tabs., 45 figs

  16. 24 CFR 886.131 - Audit.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Audit. 886.131 Section 886.131... Projects With HUD-Insured and HUD-Held Mortgages § 886.131 Audit. (a) Where a State or local government is... assistance under this part, the audit requirements in 24 CFR part 44 shall apply. (b) Where a nonprofit...

  17. A simple method for preparing radioactive capsules in colon transit study

    International Nuclear Information System (INIS)

    Wang Shyhjen; Lin Wanyu; Tsai Shihchuan; Chen Granhun

    2000-01-01

    Colon transit study is currently performed by delivering technetium-99m or indium-111 labelled activated charcoal to the colon in a methacrylate-coated capsule (coated capsule). However, the coating procedure is complicated and methacrylate has not been approved by the Food and Drug Administration. Therefore, a simpler method is needed for the clinical routine use of colon transit study. In this study, we used a commercial empty enteric capsule and a coated capsule for the measurement of colon transit time. We compared the in vitro stability and in vivo scintigraphy of 99m Tc-labelled activated charcoal in the coated capsule and the enteric capsule to evaluate the possibility of clinical usage of the enteric capsule for colon transit time study. Activated charcoal powder was mixed with 99m Tc-diethylene triamine penta-acetic acid (DTPA) and vaporized to dryness. The dry 99m Tc-DTPA activated charcoal was loaded into the coated capsule and the enteric capsule. In vitro stability study was performed by immersing these capsules in a colourless buffer of variable pH which mimicked the conditions in the stomach and the small bowel. Capsule disruption was determined. Colon transit scintigraphy with 99m Tc-DTPA charcoal was performed in five normal volunteers using these two capsules. The in vitro stability of these two types of capsule was similar and the colon transit scintigraphy findings were almost identical. Most capsules dissolved in the ascending colon and very few in the terminal ileum. It is concluded that enteric capsule is a suitable alternative to coated capsule for measurement of colon transit. (orig.)

  18. Failure of the capsule for coated particles irradiation

    International Nuclear Information System (INIS)

    Yamaki, Jikei; Nomura, Yasushi; Nagamatsuya, Takaaki; Yamahara, Takeshi; Sakai, Haruyuki

    1975-10-01

    During operation cycle No. 27 of the JMTR (Japan Material Testing Reactor) on May 20, 1974, leakage of the fission product gas occurred from the capsule 72F-7A, which contained coated particles for the irradiation; the coated particles are for the development of a multi-purpose high temperature gas cooled reactor. The capsule was designed for heat 1600 0 C. Three nickel plates as the heat reflector were sandwiched in between the plates of titanium and zirconium, which were adsorbents for the impurity gases in the cladding tube (Nb-1%Zr). Temperatures of the plates were about 1000 0 C under the irradiation, so one metal diffused into the other metal through interfaces, resulting in the formation of an alloy. Its melting point was lower than those of metals in the capsule. The cladding material Nb-1%Zr was melted by the alloy and finally a pin hole developed through the cladding. The process of failure, design of the capsule, post-irradiation test of the capsule and the failure-reproducing experiment with a mock-up capsule are described. (auth.)

  19. Liquid-core nanocellulose-shell capsules with tunable oxygen permeability.

    Science.gov (United States)

    Svagan, A J; Bender Koch, C; Hedenqvist, M S; Nilsson, F; Glasser, G; Baluschev, S; Andersen, M L

    2016-01-20

    Encapsulation of oxygen sensitive components is important in several areas, including those in the food and pharmaceutical sectors, in order to improve shelf-life (oxidation resistance). Neat nanocellulose films demonstrate outstanding oxygen barrier properties, and thus nanocellulose-based capsules are interesting from the perspective of enhanced protection from oxygen. Herein, two types of nanocellulose-based capsules with liquid hexadecane cores were successfully prepared; a primary nanocellulose polyurea-urethane capsule (diameter: 1.66 μm) and a bigger aggregate capsule (diameter: 8.3 μm) containing several primary capsules in a nanocellulose matrix. To quantify oxygen permeation through the capsule walls, an oxygen-sensitive spin probe was dissolved within the liquid hexadecane core, allowing non-invasive measurements (spin-probe oximetry, electron spin resonance, ESR) of the oxygen concentration within the core. It was observed that the oxygen uptake rate was significantly reduced for both capsule types compared to a neat hexadecane solution containing the spin-probe, i.e. the slope of the non-steady state part of the ESR-curve was approximately one-third and one-ninth for the primary nanocellulose capsule and aggregated capsule, respectively, compared to that for the hexadecane sample. The transport of oxygen was modeled mathematically and by fitting to the experimental data, the oxygen diffusion coefficients of the capsule wall was determined. These values were, however, lower than expected and one plausible reason for this was that the ESR-technique underestimate the true oxygen uptake rate in the present systems at non-steady conditions, when the overall diffusion of oxygen was very slow. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Deformation of ovalbumin-alginate capsules in a T-Junction

    Science.gov (United States)

    Häner, Edgar; Juel, Anne

    2015-11-01

    We study experimentally the flow-induced deformation of liquid-filled ovalbumin-alginate capsules in a T-junction. In applications, capsules/cells often negotiate branched networks with junctions thus experiencing large deformations. We investigate the constant volume-flux viscous flow of buoyancy-neutral thin-walled capsules close to the centreline of rectangular channels, by comparison to near-rigid gelled beads. The motion of the capsules in straight channels scales with the capillary number - the ration of viscous to elastic forces. However, the effect of elastic deformation on the motion is sufficiently weak that a rigid sphere model predicts the velocity of capsules with diameters of up to 70% of that of the channel to within 5%. In the T-junction, systematic selection of daughter channel (right-left) occurs outside a finite region around the channel centreline, by contrast with near-rigid gelled beads, where the actual centreline is the separator. We quantify the behaviour of capsules in terms of their longitudinal stretching (up to a factor of three without rupture). We show the large range of deformations encountered can be applied to the measurement of the elastic properties of capsules as well as to the geometric-induced sorting and manipulation of capsules.

  1. Development of a Low Temperature Irradiation Capsule for Research Reactor Materials

    International Nuclear Information System (INIS)

    Choo, Kee Nam; Cho, Man Soon; Lee, Cheol Yong; Yang, Sung Woo; Shin, Yoon Taek; Park, Seng Jae; Kang, Suk Hoon; Kang, Young Hwan; Park, Sang Jun

    2013-01-01

    A new capsule design was prepared and tested at HANARO for a neutron irradiation of core materials of research reactors as a part of the research reactor development project. Irradiation testing of the materials including graphite, beryllium, and zircaloy-4 that are supposed to be used as core materials in research reactors was required for irradiation at up to 8 reactor operation cycles at low temperature (<100 .deg. C). Therefore, three instrumented capsules were designed and fabricated for an evaluation of the neutron irradiation properties of the core materials (Graphite, Be, Zircaloy-4) of research reactors. The capsules were first designed and fabricated to irradiate materials at low temperature (<100 .deg. C) for a long cycle of 8 irradiation cycles at HANARO. Therefore, the safety of the new designed capsule should be fully checked before irradiation testing. Out-pile performance and endurance testing before HANARO irradiation testing was performed using a capsule under a 110% condition of a reactor coolant flow amount. The structural integrity of the capsule was analyzed in terms of a vibration-induced fatigue cracking of a rod tip of the capsule that is suspected to be the most vulnerable part of a capsule. Another two capsules were irradiated at HANARO for 4 cycles, and one capsule was transferred to a hot cell to examine the integrity of the rod tip of the capsule. After confirming the soundness of the 4 cycle-irradiated capsule, the remaining capsule was irradiated at up to 8 cycles at HANARO. Based on the structural integrity analysis of the capsule, an improved capsule design will be suggested for a longer irradiation test at HANARO

  2. Digestion of bacteria by Nais variabilis (Oligochaeta) as established by autoradiography

    International Nuclear Information System (INIS)

    Harper, R.M.; Fry, J.C.; Learner, M.A.

    1981-01-01

    Serratia marcescens grown on different tritiated substrates was fed to Nais variabilis for 40 min, 4 h, and 17 h periods. The substrates were glucose, thymidine and glycerol which labelled mainly low molecular compounds, DNA, and lipids respectively. The worms incorporated radioactive label into their tissues within 40 min of feeding on the labelled bacteria. Incorporation of label where low molecular weight compounds were labelled could be due to absorption of dissolved bacterial secretions through the gut or body wall. However, DNA is a macromolecule not secreted by bacteria, consequently the label within this molecule could only accumulate in worm tissue after digestion, absorption and assimilation. No definite pattern of uptake or translocation along the worm was conclusively established but there was some indication that uptake was greatest in the anterior region of the intestine. Bacterial lipids were digested more slowly than the other materials labelled. (author)

  3. Three-dimensional simulations of Nova capsule implosion experiments

    International Nuclear Information System (INIS)

    Marinak, M.M.; Tipton, R.E.; Landen, O.L.

    1995-01-01

    Capsule implosion experiments carried out on the Nova laser are simulated with the three-dimensional HYDRA radiation hydrodynamics code. Simulations of ordered near single mode perturbations indicate that structures which evolve into round spikes can penetrate farthest into the hot spot. Bubble-shaped perturbations can burn through the capsule shell fastest, however, causing even more damage. Simulations of a capsule with multimode perturbations shows spike amplitudes evolving in good agreement with a saturation model during the deceleration phase. The presence of sizable low mode asymmetry, caused either by drive asymmetry or perturbations in the capsule shell, can dramatically affect the manner in which spikes approach the center of the hot spot. Three-dimensional coupling between the low mode shell perturbations intrinsic to Nova capsules and the drive asymmetry brings the simulated yields into closer agreement with the experimental values

  4. Equilibrium ignition for ICF capsules

    International Nuclear Information System (INIS)

    Lackner, K.S.; Colgate, S.A.; Johnson, N.L.; Kirkpatrick, R.C.; Menikoff, R.; Petschek, A.G.

    1993-01-01

    There are two fundamentally different approaches to igniting DT fuel in an ICF capsule which can be described as equilibrium and hot spot ignition. In both cases, a capsule which can be thought of as a pusher containing the DT fuel is imploded until the fuel reaches ignition conditions. In comparing high-gain ICF targets using cryogenic DT for a pusher with equilibrium ignition targets using high-Z pushers which contain the radiation. The authors point to the intrinsic advantages of the latter. Equilibrium or volume ignition sacrifices high gain for lower losses, lower ignition temperature, lower implosion velocity and lower sensitivity of the more robust capsule to small fluctuations and asymmetries in the drive system. The reduction in gain is about a factor of 2.5, which is small enough to make the more robust equilibrium ignition an attractive alternative

  5. Automated quantitative analysis of in-situ NaI measured spectra in the marine environment using a wavelet-based smoothing technique

    International Nuclear Information System (INIS)

    Tsabaris, Christos; Prospathopoulos, Aristides

    2011-01-01

    An algorithm for automated analysis of in-situ NaI γ-ray spectra in the marine environment is presented. A standard wavelet denoising technique is implemented for obtaining a smoothed spectrum, while the stability of the energy spectrum is achieved by taking advantage of the permanent presence of two energy lines in the marine environment. The automated analysis provides peak detection, net area calculation, energy autocalibration, radionuclide identification and activity calculation. The results of the algorithm performance, presented for two different cases, show that analysis of short-term spectra with poor statistical information is considerably improved and that incorporation of further advancements could allow the use of the algorithm in early-warning marine radioactivity systems. - Highlights: → Algorithm for automated analysis of in-situ NaI γ-ray marine spectra. → Wavelet denoising technique provides smoothed spectra even at parts of the energy spectrum that exhibits strong statistical fluctuations. → Automated analysis provides peak detection, net area calculation, energy autocalibration, radionuclide identification and activity calculation. → Analysis of short-term spectra with poor statistical information is considerably improved.

  6. Positron radiography of ignition-relevant ICF capsules

    Science.gov (United States)

    Williams, G. J.; Chen, Hui; Field, J. E.; Landen, O. L.; Strozzi, D. J.

    2017-12-01

    Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 × 1012 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2 g/cm2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. We evaluate the effects of magnetic fields near the capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.

  7. Aplicaciones clínicas del radioyodo 131 (I131 en las enfermedades del tiroides Clinical applications of radioiodine 131 (I131 in the thyroid diseases

    Directory of Open Access Journals (Sweden)

    Levi González Rivero

    2012-12-01

    Full Text Available El radioyodo 131 es un isótopo radioactivo que se emplea exitosamente en el diagnóstico y tratamiento de las enfermedades benignas y malignas del tiroides. Su propiedad de integrarse selectivamente al metabolismo del tiroides y emitir una señal, le permite describir el funcionamiento glandular mediante estudios de captación, y delimitar la morfología y localización de los tejidos que capten yodo, a través de la gammagrafía. Es además una radioterapia sencilla, segura y coste-efectiva, usada como primera línea terapéutica en el control del hipertiroidismo, cuya dosis y momento de aplicación debería individualizarse según la etiología y la clínica de cada paciente. El radioyodo 131 ofrece una alternativa eficaz para reducir el tamaño del bocio no tóxico; además, respalda el tratamiento quirúrgico del carcinoma diferenciado del tiroides, y destruye a dosis ablativa los restos tisulares y las lesiones metastásicas que puede identificar durante el seguimiento gammagráfico. El empleo de radioyodo 131 está sujeto al cumplimiento de regulaciones de protección contra la radioactividad.Radioiodine 131 is a radioactive isotope that is successfully used for the diagnosis and the treatment of benign and malignant thyroid diseases. Its quality of selectively integrating to the thyroid metabolism and emitting a signal allows it to describe the gland functioning through capture studies, and to delimit the morphology and location of the tissues that capture iodine by means of gammagraphy. It is also a simple, safe and cost-effective radiotherapy used as first-line therapeutics in the control of hyperthyroidism. The dose and right time of application should be individualized according to the etiology and the clinic of each patient. Radioiodine 131 offers an efficient alternative to reduce the size of non-toxic goiter in addition to supporting the surgical treatment of the differentiated thyroid carcinoma and destroying with ablative doses

  8. Assessments of whole body scan images (PCI) obtained in patients undergoing treatment of radioiodine (pre and post-treatment); Avaliacoes das imagens de pesquisa de corpo inteiro (PCI) obtidas em pacientes submetidos ao tratamento de radioiodoterapia (pre e pos-tratamento)

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Fernanda Karolina Mendonca da; Lopes Filho, Ferdinand de Jesus; Vieira, Jose Wilson; Souza, Milena Thays Barbosa de, E-mail: fernanda.radiologia8@gmail.com, E-mail: milena_thays@hotmail.com, E-mail: jose.wilson59@uol.com.br, E-mail: ferdinand.lopes@oi.com.br [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco (IFPE), Recife, PE (Brazil)

    2014-07-01

    Nuclear medicine is a medical specialty used for diagnosis and therapy of some diseases. For the treatment of differentiated thyroid carcinoma (papillary and follicular) Radioiodine therapy is employed, in order to eliminate the rest of thyroid tissue after removal of the thyroid (thyroidectomy). In radioiodine therapy is used radioisotope iodine-131 ({sup 131}I) as Sodium Iodide (NaI). The amount of the activity (dose) of {sup 131}I administered is generally the responsibility of nuclear medicine, which is based on an image Research Length of the patient (pre-dose therapy PCI). PCI is also used after treatment (post-PCI therapeutic dose) to evaluate possible metastasis. The purpose of this study was to investigate the distribution of biokinetic {sup 131}I at length and in some organs of the patient, in order to note any similarity. Exams PCI pre-dose and post-dose were analyzed, the anterior and posterior projections of ten patients. Contours in these images (ROI - Region Of Interest) were made in the whole body and in areas with high uptake of {sup 131}I. The total score was used in the calculation to obtain the percentage distribution of {sup 13I} in the organs of the patient. The results showed that there similarity on the biodistribution of {sup 131}I between pre-dose and post-dose PCI. Therefore, it was found that it is valuable images of PCI pre-dose therapy as a way to assist the nuclear medicine physician in choosing the best activity to be administered to the patient in order to minimize the dose to adjacent organs. (author)

  9. Monitoring of garbage with a 5 x 5 NaI (Tl) detector; Monitoreo de basura con un detector de NaI (Tl) de 5 x 5

    Energy Technology Data Exchange (ETDEWEB)

    Cortes P, A.; Becerril V, A.; Angeles C, A

    1991-12-15

    So far in that is carried out the first reload of nuclear fuel in the LVC, the monitoring of garbage has been carried out using monitors trade mark Eberline model RM 14. The procedure consists in manually monitoring each object and to separate of the considered 'clean' garbage the objects considered as contaminated, which register greater or equal counts to 100 cpm. This way to process was adequate under normal operation conditions, but not in the operation rhythm that implies a bigger maintenance since the time required for monitoring from 5 to 10 kg. of garbage is of the order of 0.5 hours and the production rhythm of this it ends up being a lot but high. Due to this necessity it was thought about the problem of looking by a more efficient monitoring method. In this work a method that uses a detector of NaI (Tl) of 5 x 5 inches is discussed. (Author)

  10. Monitoring of garbage with a 5 x 5 NaI (Tl) detector; Monitoreo de basura con un detector de NaI (Tl) de 5 x 5

    Energy Technology Data Exchange (ETDEWEB)

    Cortes P, A; Becerril V, A; Angeles C, A

    1991-12-15

    So far in that is carried out the first reload of nuclear fuel in the LVC, the monitoring of garbage has been carried out using monitors trade mark Eberline model RM 14. The procedure consists in manually monitoring each object and to separate of the considered 'clean' garbage the objects considered as contaminated, which register greater or equal counts to 100 cpm. This way to process was adequate under normal operation conditions, but not in the operation rhythm that implies a bigger maintenance since the time required for monitoring from 5 to 10 kg. of garbage is of the order of 0.5 hours and the production rhythm of this it ends up being a lot but high. Due to this necessity it was thought about the problem of looking by a more efficient monitoring method. In this work a method that uses a detector of NaI (Tl) of 5 x 5 inches is discussed. (Author)

  11. Capsule-odometer: a concept to improve accurate lesion localisation.

    Science.gov (United States)

    Karargyris, Alexandros; Koulaouzidis, Anastasios

    2013-09-21

    In order to improve lesion localisation in small-bowel capsule endoscopy, a modified capsule design has been proposed incorporating localisation and - in theory - stabilization capabilities. The proposed design consists of a capsule fitted with protruding wheels attached to a spring-mechanism. This would act as a miniature odometer, leading to more accurate lesion localization information in relation to the onset of the investigation (spring expansion e.g., pyloric opening). Furthermore, this capsule could allow stabilization of the recorded video as any erratic, non-forward movement through the gut is minimised. Three-dimensional (3-D) printing technology was used to build a capsule prototype. Thereafter, miniature wheels were also 3-D printed and mounted on a spring which was attached to conventional capsule endoscopes for the purpose of this proof-of-concept experiment. In vitro and ex vivo experiments with porcine small-bowel are presented herein. Further experiments have been scheduled.

  12. Radioablative therapy with Iodine-131 on a patient with thyroid cancer and chronic renal failure in hemodialysis first experience in Peru

    International Nuclear Information System (INIS)

    Apaza Veliz, D. G.; Herrera Vera, R. D.; Cardenas Abarca, C. A.; Oporto Gonzales, C. A.; Aguilar Ramírez, C.; Urquizo Baldomero, R. M.; Vega Ramírez, J. L.

    2016-01-01

    The Iodine-131 (I-131) is a radioisotope used as a standard treatment for radioablation of thyroid remnants. Among thyroid cancer patients, the ones undergoing hemodialysis represent a specific group. The dose of I-131 is given orally to these patients, part of it is absorbed by the thyroid remnants and the rest of it, largely not incorporated, is excreted primarily by renal excretion. The use of a high dose of radioactivity in the process, and the inability of excretion, represents a high risk of exposure to the patient, medical staff and hemodialysis equipment. This work describes the procedure applied on the radioablation therapy for thyroid cancer while receiving hemodialysis, minimizing the risks for the patient and the staff involved. This clinical procedure will establish the dosimetric measures, a plan on radiation protection and a treatment protocol for this specific type of patients.

  13. Radioablative therapy with Iodine-131 on a patient with thyroid cancer and chronic renal failure in hemodialysis first experience in Peru

    Energy Technology Data Exchange (ETDEWEB)

    Apaza Veliz, D. G., E-mail: dgav02@gmail.com [Hospital Nacional Carlos Alberto Seguin Escobedo, Servicio de Medicina Nuclear, Arequipa, Perú, Universidad Nacional de San Agustín de Arequipa, Escuela de Física, Arequipa (Peru); Herrera Vera, R. D.; Cardenas Abarca, C. A.; Oporto Gonzales, C. A.; Aguilar Ramírez, C.; Urquizo Baldomero, R. M. [Hospital Nacional Carlos Alberto Seguin Escobedo, Servicio de Medicina Nuclear, Arequipa (Peru); Vega Ramírez, J. L. [Universidad Nacional de San Agustín de Arequipa, Escuela de Física, Arequipa (Peru)

    2016-07-07

    The Iodine-131 (I-131) is a radioisotope used as a standard treatment for radioablation of thyroid remnants. Among thyroid cancer patients, the ones undergoing hemodialysis represent a specific group. The dose of I-131 is given orally to these patients, part of it is absorbed by the thyroid remnants and the rest of it, largely not incorporated, is excreted primarily by renal excretion. The use of a high dose of radioactivity in the process, and the inability of excretion, represents a high risk of exposure to the patient, medical staff and hemodialysis equipment. This work describes the procedure applied on the radioablation therapy for thyroid cancer while receiving hemodialysis, minimizing the risks for the patient and the staff involved. This clinical procedure will establish the dosimetric measures, a plan on radiation protection and a treatment protocol for this specific type of patients.

  14. Radioablative therapy with Iodine-131 on a patient with thyroid cancer and chronic renal failure in hemodialysis first experience in Peru

    Science.gov (United States)

    Apaza Veliz, D. G.; Herrera Vera, R. D.; Cardenas Abarca, C. A.; Oporto Gonzales, C. A.; Aguilar Ramírez, C.; Vega Ramírez, J. L.; Urquizo Baldomero, R. M.

    2016-07-01

    The Iodine-131 (I-131) is a radioisotope used as a standard treatment for radioablation of thyroid remnants. Among thyroid cancer patients, the ones undergoing hemodialysis represent a specific group. The dose of I-131 is given orally to these patients, part of it is absorbed by the thyroid remnants and the rest of it, largely not incorporated, is excreted primarily by renal excretion. The use of a high dose of radioactivity in the process, and the inability of excretion, represents a high risk of exposure to the patient, medical staff and hemodialysis equipment. This work describes the procedure applied on the radioablation therapy for thyroid cancer while receiving hemodialysis, minimizing the risks for the patient and the staff involved. This clinical procedure will establish the dosimetric measures, a plan on radiation protection and a treatment protocol for this specific type of patients.

  15. Pneumatic capsule with a measuring system for in-pile irradiation

    International Nuclear Information System (INIS)

    Oshima, Keiichi; Yamazaki, Yasaburo; Hirata, Mitsuho; Ishii, Toshio; Shimozawa, Ryohei.

    1967-01-01

    A prior-art in-pile irradiation apparatus wherein a rabbit containing an irradiation specimen therein is inserted into and removed from a pile by a pneumatic system does not include means for measuring the temperature and pressure of the specimen under irradiation. When the rabbit is deformed during irradiation, it cannot be reliably recovered. A pneumatic capsule assembly with a measuring system according to this invention has a double structure which consists of an inner capsule containing the specimen therein and an outer capsule evacuated or filled with a gas. A thermocouple lace wire and a strain gauge are welded on the outside surface of the inner capsule as detection terminals for measuring the temperature and pressure. A rupture plate which bursts when the pressure in the inner capsule reaches a predetermined value is provided at a part of the inner capsule, and a fin for heat transmission is provided between the inner and outer capsules to thus prevent the deformation of the pneumatic capsule assembly as a whole. (Takasuka, S.)

  16. Tongxinluo (Tong xin luo or Tong-xin-luo) capsule for unstable angina pectoris.

    Science.gov (United States)

    Wu, Taixiang; Harrison, R A; Chen, Xiaoyan; Ni, Juan; Zhou, Likun; Qiao, Jieqi; Wang, Qin; Wei, Jiafu; Xin, Duan; Zheng, Jie

    2006-10-18

    Tongxinluo capsule is a medicine consisting of traditional Chinese herbs and insects used for cardiovascular diseases in China and some other Asian countries. To date the evidence of its effect has not previously been subject to systematic review, making it difficult to derive robust conclusions about its actual benefits, and indeed, possible harms. To assess systematically the effects of tongxinluo capsule in people with unstable angina pectoris. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) on The Cochrane Library, Issue 4 2004, MEDLINE, EMBASE, Chinese Biomedical Database, China National Knowledge Infrastructure, Japana Centra Revuo Medicina (all 1995 to 2005). We also handsearched the relevant Chinese journals, checked with manufacturers and registers of ongoing studies. Randomised trials comparing either tongxinluo capsule only or standard treatment plus tongxinluo capsule with standard treatment or other anti-angina pectoris drugs, placebo or no intervention. Two authors identified relevant studies for the review independently and went on to abstract data, and assess trial quality. Authors of included studies were contacted to obtain further information as required. 18 short term follow-up trials involving 1413 people were included. The studies did not provide strong support of a benefit of tongxinluo for reducing the combined outcome of acute myocardial infarction, angioplasty (PTCA) coronary artery bypass graft (CABG) and sudden death or all-cause mortality (RR 0.42, 95% CI 0.07 to 2.59, P=0.35; RR 0.33, 95% CI 0.01to 7.78, P=0.49, respectively). Tongxinluo reduced the frequency of acute angina attacks (WMD -1.20, 95%CI -1.38 to -1.02, P<0.00001 and RR -2.36, 95%CI -2.53 to -2.18, P<0.00001, respectively), improved ECG (RR 1.31, 95% CI 1.08 to 1.57, P=0.005) and angina symptoms (RR 1.21, 95% CI 1.06 to 1.40; P=0.007). Tongxinluo in combination with routine angina therapy appears to reduce the risk of subsequent AMI, PTCA or CABG

  17. No stabilizing effect of the elbow joint capsule. A kinematic study

    DEFF Research Database (Denmark)

    Nielsen, K K; Olsen, Bo Sanderhoff

    1999-01-01

    We dissected 7 cadaveric elbow specimens, leaving the collateral ligaments and the joint capsule intact. The anterior and the posterior capsule were sequentially transected, followed by kinematic testings. We found no change in joint laxity after total transection of the capsule.......We dissected 7 cadaveric elbow specimens, leaving the collateral ligaments and the joint capsule intact. The anterior and the posterior capsule were sequentially transected, followed by kinematic testings. We found no change in joint laxity after total transection of the capsule....

  18. [Radioiodine 131I therapy of hyperthyroidism on an outpatient basis - safe, effective and economic option].

    Science.gov (United States)

    Jiskra, J; Kubinyi, J; Telička, Z

    2012-02-01

    Radioiodine 131I therapy of hyperthyroidism on an outpatient basis is widely accepted over the world. In Czech Republic, however, radioiodine therapy is still not enough used, and has been realized on an inpatient basis to date. Our work is the first analysis of the experiences with radioiodine therapy of hyperthyroidism on an outpatient basis in Czech Republic. Capsule with 550 MBq of 131I was administered orally in 39 hyperthyroid patients (32 women and 8 men, 21 with autoimmune Graves hyperthyroidism and 18 with toxic thyroid nodules, mean age 66.8 years). In 32 of them we evaluated effectiveness and complications of therapy after 12-42 months. We also compared financial costs of the radioiodine treatment on an outpatient basis with the treatment in hospitalization and with surgery. After the treatment, 9/32 (28 %) patients were euthyroid without thyrostatic/thyroxine treatment, 18/32 (60 %) patients were hypothyroid with thyroxine therapy, 2/32 (6 %) patients significantly decreased doses of thyrostatic drugs. In 2/32 (6 %) patients the treatment was ineffective. The effect of the treatment did not depend on the etiology and severity of hyperthyroidism, but decreased with thyroid volume. Patients with ineffective or only partially effective treatment had median of thyroid volume more than 40 ml. In 1 patient thyroid associated ophthalmopathy was moderately worsened. Other complications were not observed. If we compared financial costs in model with 1 patient, we found that the costs of radioiodine therapy on an outpatient basis (118.7 €) comprise only 16 % of the costs of radioiodine therapy in hospitalization (728 €) and only 25 % of the costs of surgery (475.6 €). Radioiodine 131I is effective and safe in the treatment of hyperthyroidism and the therapy on an outpatient basis is much cheaper choice. The therapy with 131I on an outpatient basis is not suitable in patients with thyroid volume more than 40 ml.

  19. Radioactive gas-containing polymeric capsule

    International Nuclear Information System (INIS)

    Winchell, H.S.; Lewis, R.E.

    1975-01-01

    A disposable ventilation study system for dispensing a single patient dosage of gaseous radioisotopes to patients for pulmonary function studies is disclosed. A gas impermeable capsule encloses the gaseous radioisotope and is stored within a radioactivity shielding body of valve means which shears the capsule to dispense the radioisotope to the patient. A breathing bag receives the patient's exhalation of the radioisotope and permits rebreathing of the radioisotope by the patient. 18 claims, 7 drawing figures

  20. Design procedure of capsule with multistage heater control (named MUSTAC)

    International Nuclear Information System (INIS)

    Someya, Hiroyuki; Endoh, Yasuichi; Hoshiya, Taiji; Niimi, Motoji; Harayama, Yasuo

    1990-11-01

    A capsule with electric heaters at multistage (named MUSTAC) is a type of capsule used in JMTR. The heaters are assembled in the capsule. Supply electric current to the heaters can be independently adjusted with a control systems that keeps irradiation specimens to constant temperature. The capsule being used, the irradiation specimen are inserted into specimen holders. Gas-gap size, between outer surface of specimen holders and inner surface of capsule casing, is calculated and determined to be flatten temperature of loaded specimens over the region. The rise or drop of specimen temperature in accordance with reactor power fluctuations is corrected within the target temperature of specimen by using the heaters filled into groove at specimen holder surface. The present report attempts to propose a reasonable design procedure of the capsules by means of compiling experience for designs, works and irradiation data of the capsules and to prepare for useful informations against onward capsule design. The key point of the capsule lies on thermal design. Now design thermal calculations are complicated in case of specimen holder with multihole. Resolving these issues, it is considered from new on that an emphasis have to placed on settling a thermal calculation device, for an example, a computer program on calculation specimen temperature. (author)

  1. Evaluation by computed tomography of the destruction of the internal capsule in hypertensive intracerebral hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Tomita, Yukio; Ohuchi, Tadao; Yukawa, Hideki; Konno, Jyoji; Saiki, Iwao (Iwate Medical Coll., Morioka (Japan). School of Medicine)

    1983-12-01

    Seventy-five patients, 37 with putaminal hemorrhage and 38 with thalamic hemorrhage. were examined by CT immediately after the ictus and while the patients were undergoing conservative treatment. The distance was measured on every CT from the center of the pineal body to the inside edge of the hematoma in the putaminal hemorrhage and to the outside edge in the thalamic hemorrhage, by using a slice 5 cm above the orbitomeatal line on which the pineal body was clearly recognizable. At 6 months after ictus, recuperations from hemiplegia were estimated in all patients and compared with the degree of the measured distance on CT. In the group of patients who had recovered completely from hemiplegia, the degrees were more than 28 mm in the cases of putaminal hemorrhage and less than 32 mm in the cases of thalamic hemorrhage. If the degrees were under 25 mm in the putaminal hemorrhage or over 36 mm in the thalamic hemorrhage, no rehabilitation was effective for their paralytic upper extremities. Measurements of the internal capsule were also performed on three fresh brains without cerebral disease. The normal values of the distance were 34.7+-1.0 mm from the center of the pineal body to the outside edge of the posterior limb of the internal capsule and 25.0+-0.9 mm to its inside edge. Judging from these results, it is thought that the attainable limits of avoiding destruction of the posterior limb of the internal capsule by the hematoma are 28 mm in the case of a putaminal hemorrhage and 32 mm in the case of a thalamic hemorrhage. Therefore, it was considered that the internal capsule can be shifted about 7 mm to the medial or lateral side without any direct or indirect effects from the hematoma.

  2. Ingestible capsule for remote controlled release of a substance

    DEFF Research Database (Denmark)

    2014-01-01

    The application relates to an ingestible capsule (102) for delivery of a substance e.g. a pharmaceutical drug, to a human or animal. The ingestible capsule comprises a capsule wall structure (202) forming a substantially sealed reservoir or lumen holding the substance (204). An electrical resonance...

  3. Analysis of pelvic 131I uptake after 131I whole body scan in patients with thyroid cancer

    International Nuclear Information System (INIS)

    Kou Ying; Liu Jianzhong; Hao Xinzhong; Wu Lixiang; Lu Keyi; Yang Suyun; Shi Xiaoli; Hu Tingting

    2014-01-01

    Objective: To analyze and explore the possible mechanism for pelvic 131 I uptake after 131 I post treatment whole body scan (Rx-WBS)in patients with differentiated thyroid cancer. Methods: (1) Data were retrospectively reviewed from 168 female patients with differentiated thyroid cancer (everyone has a Rx-WBS). (2) 46 patients were accepted by analyzing the characteristics of Rx-WBS and combing with some inclusion criteria,and then followed up. Results: Among the 46 patients (46 positions accumulated 131 I) with significant pelvic 131 I uptake, 6 patients had two reasons leading to pelvic 131 I uptake, and 2 patients had no specific reason. Among the 50 reasons for pelvic 131 I uptake, 41 reasons related with uterus, 3 reasons related to rectum, 5 related to bladder and 1 related to ovarian chocolate cyst. Among the 41 reasons related to uterus, by combining the examinations of SPECT/CT, ultrasound, CT and the follow-up results, 18 were uterine leiomyomas, 9 were intrauterine devices, 2 were endometrial thickening, 3 were uterine cavity effusion, 7 were menstrual periods, 1 were uterine adenomyosis, 1 were gestational sac. Conclusions: (1) In the Rx-WBS of female, the significant pelvic 131 I uptake is generally caused by uterus, but not bladder. And it usually means gynecological disease, especially uterine leiomyomas when excluding physiological factors. (2) It is generally easy to differentiate bladder from rectum because they have different characteristic features of the pelvic 131 I uptake. (3) SPECT/CT plays a very important role in locating 131 I uptake in uterus. (authors)

  4. Spheroidal and conical shapes of ferrofluid-filled capsules in magnetic fields

    Science.gov (United States)

    Wischnewski, Christian; Kierfeld, Jan

    2018-04-01

    We investigate the deformation of soft spherical elastic capsules filled with a ferrofluid in external uniform magnetic fields at fixed volume by a combination of numerical and analytical approaches. We develop a numerical iterative solution strategy based on nonlinear elastic shape equations to calculate the stretched capsule shape numerically and a coupled finite element and boundary element method to solve the corresponding magnetostatic problem and employ analytical linear response theory, approximative energy minimization, and slender-body theory. The observed deformation behavior is qualitatively similar to the deformation of ferrofluid droplets in uniform magnetic fields. Homogeneous magnetic fields elongate the capsule and a discontinuous shape transition from a spheroidal shape to a conical shape takes place at a critical field strength. We investigate how capsule elasticity modifies this hysteretic shape transition. We show that conical capsule shapes are possible but involve diverging stretch factors at the tips, which gives rise to rupture for real capsule materials. In a slender-body approximation we find that the critical susceptibility above which conical shapes occur for ferrofluid capsules is the same as for droplets. At small fields capsules remain spheroidal and we characterize the deformation of spheroidal capsules both analytically and numerically. Finally, we determine whether wrinkling of a spheroidal capsule occurs during elongation in a magnetic field and how it modifies the stretching behavior. We find the nontrivial dependence between the extent of the wrinkled region and capsule elongation. Our results can be helpful in quantitatively determining capsule or ferrofluid material properties from magnetic deformation experiments. All results also apply to elastic capsules filled with a dielectric liquid in an external uniform electric field.

  5. 40 CFR 131.40 - Puerto Rico

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 21 2010-07-01 2010-07-01 false Puerto Rico 131.40 Section 131.40... Federally Promulgated Water Quality Standards § 131.40 Puerto Rico (a) Use designations for marine waters. In addition to the Commonwealth's adopted use designations, the following waterbodies in Puerto Rico...

  6. Measurement of the dose to the family members taking care of thyroid cancer patients undergoing I-131 therapy in nuclear medicine using TLD-100

    International Nuclear Information System (INIS)

    Zehtabian, M.; Dehghan, N.; Danaei Ghazanfarkhani, M.; Haghighatafshar, M.; Sina, S.

    2017-01-01

    The family members or friends of the patients undergoing treatment using radioiodine in nuclear medicine are inevitably exposed to ionization radiation. The purpose of this study is measurement of the dose received by the people taking care of the thyroid cancer patients treated by "1"3"1I. For this purpose, the dose amounts received by 29 people accompanying patients were measured using thermoluminescence dosimeters. A badge containing three TLD-100 chips was given to each caregiver. The people were asked to wear the badges for 24 days, when they are taking care of the patients. Finally the dose to each person was estimated by averaging the readings of the three TLDs. The measured dose amounts to the people were compared with the recommendations of international commissions. According to the results obtained in this study, the amounts of dose received by the caregivers were between 0.03 and 0.38 mSv, with the average of 0.12 mSv. By comparison of the results of this study with the recommendations of International Commission on Radiological Protection (ICRP), it can be observed that the dose to family members of the patients is less than the dose constraints. However, it is recommended that the caregivers be aware of the radiation protection principles in order to reduce their dose. (authors)

  7. Production of Ba-131/Cs-131 for use in radiotherapy implants. Project 3

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    The conditions for the irradiation of anhydrous cesium chloride have been determined for 40 MeV proton beam currents up to 5 microamps. A method for the chemical separation of Ba-131 from the irradiated target material has been developed using chelex-100 ion exchange resin. The elution of Cs-131 from the column has been achieved using 0.2M NH 4 Cl solution, which can be evaporated to dryness, the NH 4 Cl sublimed off, and the Cs-131 obtained as a no-carrier added solid free of other ions, suitable for incorporation into glass or ceramic seeds. 3 refs., 2 figs., 1 tab

  8. 21 CFR 131.115 - Concentrated milk.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Concentrated milk. 131.115 Section 131.115 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION MILK AND CREAM Requirements for Specific Standardized Milk and Cream § 131.115...

  9. 21 CFR 131.130 - Evaporated milk.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Evaporated milk. 131.130 Section 131.130 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION MILK AND CREAM Requirements for Specific Standardized Milk and Cream § 131.130 Evaporated milk. (a...

  10. Scaling effects in spiral capsule robots.

    Science.gov (United States)

    Liang, Liang; Hu, Rong; Chen, Bai; Tang, Yong; Xu, Yan

    2017-04-01

    Spiral capsule robots can be applied to human gastrointestinal tracts and blood vessels. Because of significant variations in the sizes of the inner diameters of the intestines as well as blood vessels, this research has been unable to meet the requirements for medical applications. By applying the fluid dynamic equations, using the computational fluid dynamics method, to a robot axial length ranging from 10 -5 to 10 -2  m, the operational performance indicators (axial driving force, load torque, and maximum fluid pressure on the pipe wall) of the spiral capsule robot and the fluid turbulent intensity around the robot spiral surfaces was numerically calculated in a straight rigid pipe filled with fluid. The reasonableness and validity of the calculation method adopted in this study were verified by the consistency of the calculated values by the computational fluid dynamics method and the experimental values from a relevant literature. The results show that the greater the fluid turbulent intensity, the greater the impact of the fluid turbulence on the driving performance of the spiral capsule robot and the higher the energy consumption of the robot. For the same level of size of the robot, the axial driving force, the load torque, and the maximum fluid pressure on the pipe wall of the outer spiral robot were larger than those of the inner spiral robot. For different requirements of the operating environment, we can choose a certain kind of spiral capsule robot. This study provides a theoretical foundation for spiral capsule robots.

  11. Malignant disease after iodine-131 therapy

    International Nuclear Information System (INIS)

    Holm, L.E.; Hall, P.; Lundell, G.

    1991-01-01

    Iodine-131 therapy is one of the most common treatments for hyperthyroidism and thyroid cancer. Data on man exposed to 131-I are still scarce, and there is concern as to its possible genetic and carcinogenic effects. No overall increased cancer risk has been observed in patients receiving 131-I therapy for hyperthyroidism. Two studies have reported increased risks for leukemia after 131-I therapy for throid cancer. Different sites have been demonstrated to be at increased cancer risk in different record-linkage studies of thyroid cancer patients, e.g. bone-marrow, breast and kidney, nervous tissue, and connective tissue. However, the findings are not consistent. This article presents results from a Swedish multicenter cohort study analyzing risks of second primary tumors in patients treated with 131-I for hyperthyroidism or thyroid cancer. 10 refs

  12. Design of Endoscopic Capsule With Multiple Cameras.

    Science.gov (United States)

    Gu, Yingke; Xie, Xiang; Li, Guolin; Sun, Tianjia; Wang, Dan; Yin, Zheng; Zhang, Pengfei; Wang, Zhihua

    2015-08-01

    In order to reduce the miss rate of the wireless capsule endoscopy, in this paper, we propose a new system of the endoscopic capsule with multiple cameras. A master-slave architecture, including an efficient bus architecture and a four level clock management architecture, is applied for the Multiple Cameras Endoscopic Capsule (MCEC). For covering more area of the gastrointestinal tract wall with low power, multiple cameras with a smart image capture strategy, including movement sensitive control and camera selection, are used in the MCEC. To reduce the data transfer bandwidth and power consumption to prolong the MCEC's working life, a low complexity image compressor with PSNR 40.7 dB and compression rate 86% is implemented. A chipset is designed and implemented for the MCEC and a six cameras endoscopic capsule prototype is implemented by using the chipset. With the smart image capture strategy, the coverage rate of the MCEC prototype can achieve 98% and its power consumption is only about 7.1 mW.

  13. 21 CFR 131.206 - Nonfat yogurt.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Nonfat yogurt. 131.206 Section 131.206 Food and... CONSUMPTION MILK AND CREAM Requirements for Specific Standardized Milk and Cream § 131.206 Nonfat yogurt. (a) Description. Nonfat yogurt is the food produced by culturing one or more of the optional dairy ingredients...

  14. 21 CFR 131.203 - Lowfat yogurt.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Lowfat yogurt. 131.203 Section 131.203 Food and... CONSUMPTION MILK AND CREAM Requirements for Specific Standardized Milk and Cream § 131.203 Lowfat yogurt. (a) Description. Lowfat yogurt is the food produced by culturing one or more of the optional dairy ingredients...

  15. Capsule Shields the Function of Short Bacterial Adhesins

    OpenAIRE

    Schembri, Mark A.; Dalsgaard, Dorte; Klemm, Per

    2004-01-01

    Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can occur in other gram-negative bacteria. Likewise, we show that other short adhesins exemplified by the AIDA-I protein are blocked by the presence of a capsule. The results support the notion that cap...

  16. Moisture diffusion and permeability characteristics of hydroxypropylmethylcellulose and hard gelatin capsules.

    Science.gov (United States)

    Barham, Ahmad S; Tewes, Frederic; Healy, Anne Marie

    2015-01-30

    The primary objective of this paper is to compare the sorption characteristics of hydroxypropylmethylcellulose (HPMC) and hard gelatin (HG) capsules and their ability to protect capsule contents. Moisture sorption and desorption isotherms for empty HPMC and HG capsules have been investigated using dynamic vapour sorption (DVS) at 25°C. All sorption studies were analysed using the Young-Nelson model equations which distinguishes three moisture sorption types: monolayer adsorption moisture, condensation and absorption. Water vapour diffusion coefficients (D), solubility (S) and permeability (P) parameters of the capsule shells were calculated. ANOVA was performed with the Tukey comparison test to analyse the effect of %RH and capsule type on S, P, and D parameters. The moisture uptake of HG capsules were higher than HPMC capsules at all %RH conditions studied. It was found that values of D and P across HPMC capsules were greater than for HG capsules at 0-40 %RH; whereas over the same %RH range S values were higher for HG than for HPMC capsules. S values decreased gradually as the %RH was increased up to 60% RH. To probe the effect of moisture ingress, spray dried lactose was loaded into capsules. Phase evolution was characterised by scanning electron microscopy (SEM), X-ray powder diffraction (XRD), and differential scanning calorimetry (DSC). The capsules under investigation are not capable of protecting spray dried lactose from induced solid state changes as a result of moisture uptake. For somewhat less moisture sensitive formulations, HPMC would appear to be a better choice than HG in terms of protection of moisture induced deterioration. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Utilization of the capsule out-pile test facilities(2000-2003)

    Energy Technology Data Exchange (ETDEWEB)

    Cho, M. S.; Oh, J. M.; Cho, Y. G. and others

    2003-06-01

    Two out-pile test facilities were installed and being utilized for the non-irradiation tests outside the HANARO. The names of the facilities are the irradiation equipment design verification test facilities and the one-channel flow test device. In these facilities, the performance test of all capsules manufactured before loading in the HANARO and the design verification test for newly developed capsules were performed. The tests in these facilities include loading/unloading, pressure drop, endurance and vibration test etc. of capsules. In the period 2000{approx}2003, the performance tests for 8 material capsules of 99M-01K{approx}02M-05U were carried out, and the design verification tests of creep and fuel capsules developed newly were performed. For development of the creep capsule, pressure drop measurement, operation test of heater, T/C, LVDT and stress loading test were performed. In the design stage of the fuel capsule, the endurance and vibration test besides the above mentioned tests were carried out for verification of the safe operation during irradiation test in the HANARO. And in-chimeny bracket and the capsule supporting system were fixed and the flow tubes and the handling tools were manufactured for use at the facilities.

  18. Comparative study of 131I with 131I plus lithium carbonate in the treatment of Graves' hyperthyroidism

    International Nuclear Information System (INIS)

    Kang Yuguo; Kuang Anren; Guan Changtian

    2003-01-01

    Objective: To evaluate the effects of lithium carbonate on serum TSH, FT 3 , FT 4 and thyroid mass volume in patients with Graves' hyperthyroidism treated with 131 I. Methods: Thirty patients with newly diagnosed, untreated Graves' disease (GD) and nonsevere or absent Graves' ophthalmopathy, were randomly assigned to group 1 and group 2. The 1st group was treated with 131 I therapy only, the 2nd group with 131 I plus lithium carbonate. All subjects were evaluated for changes in serum TSH, FT 3 and FT 4 as well as thyroid mass volume at the 7, 14, 30 d after 131 I therapy. Differences between the two groups in thyroid mass volume, serum FT 4 , FT 3 , and TSH levels at each interval were evaluated by ANCOVA. Results: Serum FT 4 and FT 3 levels increased shortly after 131 I therapy only in group 1, and decreased in group 2. The differences of serum FT 3 and FT 4 levels between the two groups were significant. Conclusion: It is important for GD patients to accept lithium carbonate treatment and 131 I therapy simultaneously in order to decrease the serum FT 3 and FT 4 levels caused by 131 I therapy

  19. Radiation Exposure to Relatives of Patients Treated with Iodine-131 for Thyroid Cancer at Siriraj Hospital

    International Nuclear Information System (INIS)

    Tonnonchiang, S.; Sritongkul, N.; Chaudakshetrin, P.; Tuntawiroon, M.

    2012-01-01

    Thyroid carcinoma patients treated with I-131 are potential source of high radiation exposure to relatives who are knowingly and willingly exposed to ionizing radiation as a result of providing support and comfort to patients undergoing radionuclide therapy. The purpose of this study is to present the results of measurements of radiation doses to relatives who designated to care fornon self-supporting patients treated with radioiodine at Radionuclide Therapy Ward, Siriraj Hospital. Twenty caregivers of 20 patients underwent radioiodine therapy for thyroid cancers with a standard protocol were given specific instructions with regard to radiation safety and provided with electronic digital dosimeter (PDM 112) to continuously measure radiation dose received on the daily basis, during three days in the hospital. On the day of patients' release, in vivo bioassays were performed on caregivers to determine the thyroid uptake estimates. The 3-day accumulative doses to caregivers to patients receiving 5.55 GBq (n=11) and 7.4 GBq (n=9) of I-131 ranged from 37 to 333 μSv and 176 to 1920 μSv respectively depending on the extent and level of supports required. The thyroid uptake estimates in all caregivers were undetectable. Electronic dosimeters indicated a maximum whole-body effective dose of 1920 μSv was more than the public dose limit of 1 mSv but within the general dose constraint of 5 mSv. Radiation dose to caregivers of a non self-supporting hospitalized patient undergoing radioiodine therapy were well below the limits recommended by the ICRP and the IAEA. The patients can be comforted with confidence that dose to caregivers will be below the 5- mSv limit. This study provides guidance for medical practitioners to obtain practical radiation safety concerns associated with hospitalized patients receiving I-131 therapy especially when patients are comforted in the hospital ward by caregivers. (author)

  20. Approaches to contamination problems of agricultural land using Na(I) Tl spectrometer and gamma camera

    International Nuclear Information System (INIS)

    Yin, Yong-Gen; Suzui, Nobuo; Kawachi, Naoki; Ishii, Satomi; Fujimaki, Shu; Yamaguchi, Mitsutaka; Tanoi, Keitaro; Nakanishi, Tomoko M.; Chino, Mitsuo; Nakamura, Shin-ichi; Watabe, Hiroshi; Yamamoto, Seiichi

    2012-01-01

    The severe accident of Fukushima Daiichi Nuclear Power Plant made a large area of agricultural land contaminated with radioactive cesium (Cs-134 and 137). Quantitative analysis for radioactivity (discriminating for Cs-134 and Cs-137) taken in vegetables from the land was carried out using NaI (Tl) scintillation spectrometer. Development of gamma camera for their imaging due to Cs 137 was performed. The shape of the peaks in the spectrum, baseline suppression, a solution of lines overlapping, enhancement of high-resolution were studied. Furthermore, the effect of water on cesium absorbing and transferring process from the root to the tissue was studied. (S. Ohno)

  1. Diffusion of Na(I), Cs(I), Sr(II) and Eu(III) in smectite rich natural clay.

    Science.gov (United States)

    Kasar, Sharayu; Kumar, Sumit; Bajpai, R K; Tomar, B S

    2016-01-01

    Diffusion of Na(I), Cs(I), Sr(II) and Eu(III) in smectite rich natural clay, proposed as a backfill material in the Indian geological repository, was studied using the out-diffusion method. Radiotracers (22)Na, (137)Cs, (85)Sr and (154)Eu were used; the first three are carrier-free enabling experimental work at sub-micromolar metal ion concentration, and Eu(III) tracer (154)Eu was used at sub millimolar concentration. An out-diffusion methodology, wherein a thin planar source of radioactivity placed between two clay columns diffuses out, was used to obtain the apparent diffusion coefficient (Da) values. This methodology enabled determination of diffusion coefficient even for strongly sorbing (154)Eu. Da values for (22)Na, (137)Cs, (85)Sr and (154)Eu were 2.35 (±0.14) × 10(-11), 2.65 (±0.09) × 10(-12), 3.32 (±0.15) × 10(-11) and 1.23 (±0.15) × 10(-13) m(2) s(-1), respectively. Da values were found to be in fair agreement with literature data reported for similar mineralogical sediments. Sorption of radionuclides on the clay was also determined in the present study and differences in Da values were rationalized on the basis of sorption data. Distribution ratios (Kd) for Cs(I) and Eu(III) were higher than that for Sr(II), which in turn was higher than that for Na(I). Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Clinical applications of radioiodine 131 (I131) in the thyroid diseases

    International Nuclear Information System (INIS)

    Gonzalez Rivero, Levi; Turcios Trista, Silvia Elena; Velasco Mirabal, Milagros

    2012-01-01

    Radioiodine 131 is a radioactive isotope that is successfully used for the diagnosis and the treatment of benign and malignant thyroid diseases. Its quality of selectively integrating to the thyroid metabolism and emitting a signal allows it to describe the gland functioning through capture studies, and to delimit the morphology and location of the tissues that capture iodine by means of scintigraphy. It is also a simple, safe and cost-effective radiotherapy used as first-line therapeutics in the control of hyperthyroidism. The dose and right time of application should be individualized according to the etiology and the clinic of each patient. Radioiodine 131 offers an efficient alternative to reduce the size of non-toxic goiter in addition to supporting the surgical treatment of the differentiated thyroid carcinoma and destroying with ablative doses the tissular remains and the metastatic lesions that can be detected during the gammagraphic follow-up. Radioiodine 131 depends on the fulfillment of safety regulations against radioactivity

  3. Clinical applications of radioiodine 131 (I131) in the thyroid diseases

    International Nuclear Information System (INIS)

    Gonzalez, Rivero Levi; Turcios Trista, Silvia Elena; Velasco Mirabal, Milagros

    2012-01-01

    Radioiodine 131 is a radioactive isotope that is successfully used for the diagnosis and the treatment of benign and malignant thyroid diseases. Its quality of selectively integrating to the thyroid metabolism and emitting a signal allows it to describe the gland functioning through capture studies, and to delimit the morphology and location of the tissues that capture iodine by means of gammagraphy. It is also a simple, safe and cost-effective radiotherapy used as first-line therapeutics in the control of hyperthyroidism. The dose and right time of application should be individualized according to the etiology and the clinic of each patient. Radioiodine 131 offers an efficient alternative to reduce the size of non-toxic goiter in addition to supporting the surgical treatment of the differentiated thyroid carcinoma and destroying with ablative doses the tissular remains and the metastatic lesions that can be detected during the gammagraphic follow-up. Radioiodine 131 depends on the fulfillment of safety regulations against radioactivity

  4. Development of Multiple Capsule Robots in Pipe

    Directory of Open Access Journals (Sweden)

    Shuxiang Guo

    2018-05-01

    Full Text Available Swallowable capsule robots which travel in body cavities to implement drug delivery, minimally invasive surgery, and diagnosis have provided great potential for medical applications. However, the space constraints of the internal environment and the size limitations of the robots are great challenges to practical application. To address the fundamental challenges of narrow body cavities, a different-frequency driven approach for multiple capsule robots with screw structure manipulated by external electromagnetic field is proposed in this paper. The multiple capsule robots are composed of driven permanent magnets, joint permanent magnets, and a screw body. The screw body generates a propulsive force in a fluidic environment. Moreover, robots can form new constructions via mutual docking and release. To provide manipulation guidelines for active locomotion, a dynamic model of axial propulsion and circumferential torque is established. The multiple start and step-out frequencies for multiple robots are defined theoretically. Moreover, the different-frequency driven approach based on geometrical parameters of screw structure and the overlap angles of magnetic polarities is proposed to drive multiple robots in an identical electromagnetic field. Finally, two capsule robots were prototyped and experiments in a narrow pipe were conducted to verify the different motions such as docking, release, and cooperative locomotion. The experimental results demonstrated the validity of the driven approach for multiple capsule robots in narrow body cavities.

  5. Dynamic computed tomography of hepatocellular carcinoma with particular reference to capsule

    Energy Technology Data Exchange (ETDEWEB)

    Otsuji, Hideaki [Nara Prefectural Hospital (Japan); Uchida, Hideo; Ohishi, H

    1983-11-01

    Dynamic CT of 117 hepatocellular carcinoma was analyzed about the capsule. Capsules were detected in 57 cases (49%) and they were classified into three types. The tumor showed high density during 15 to 26 sec after bolus injection of conrast medium, but the capsule was not enhanced. Incidence of the capsule enhanced as ring high density was 73% during 37 to 90 sec and over 90% after 4 min. Dynamic CT was very useful in the elucidation of hemodynamics of capsules of hepatocellular carcinoma.

  6. Results from annual testing of ARECO cesium capsules from 1990-1994

    Energy Technology Data Exchange (ETDEWEB)

    Lundeen, J.E.

    1994-10-01

    The purpose of this report is to compile the results of the cesium capsule inspections and testing at the Applied Radiant Energy Corporation (ARECO) facility in Lynchburg, VA, performed in 1990, 1991, 1992, 1993, and 1994. The 25 cesium capsules at the ARECO facility were visually identified and clunk tested. A Go/No Go gauge test was required for capsules failing the clunk test. A visual inspection of capsules was required for the initial testing (1990). All 25 capsules passed the inspections and testing each year.

  7. Preliminary study of the distribution of dose in patients with Graves' disease undergoing examination of uptake of iodine-131 using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Schwarcke, Marcelo; Marques, Tatiana; Nicolucci, Patricia; Baffa, Oswaldo; Bornemann, Clarissa

    2010-01-01

    Patients with Graves disease have a high hormonal disorder, which causes behavioral changes. One way to treat this disease is the use of high doses of 131 Iodine, requiring that the patient carries out the examination of 131 I uptake to estimate the activity to be administered. Using these data capture and compared with the simulated data using the Monte Carlo code PENELOPE is possible to determine a distribution of dose to the region surrounding the thyroid. As noted the difference between the simulated values and the experimentally obtained were 10.36%, thus showing the code of simulation for accurate determination of absorbed dose in tissue near the thyroid. (author)

  8. High-gain capsule design for the HIDIF project

    International Nuclear Information System (INIS)

    Honrubia, J.J.; Cerrada, J.A.; Gomez, R.

    2000-01-01

    A high-gain capsule has been designed for the HIDIF project. The goal has been to relax the accelerator requirements by using a radiation pulse with lower peak temperature (220 eV) than previous designs (260 eV). The ablator material is beryllium doped with a very low concentration (0.2 atom %) of copper. The capsule absorbs 1.3 MJ and yields, approximately, 450 MJ in I-D simulations. The effect of the opacity of the ablator on capsule performance has been studied in detail. (authors)

  9. Thyroid cancer following 131I therapy for hyperthyroidism

    International Nuclear Information System (INIS)

    Watanabe, Iwao

    1980-01-01

    A women aged 37 who had thyroid cancer after 131 I therapy for hyperthyroidism was reported. She had received various conservative therapies and surgical treatments for hyperthyroidism for 10 years before 131 I therapy. Similar cases were picked out from many reports, and their clinical characteristics were discussed. The incidence of thyroid cancer after 131 I therapy, age and sex of patients, dosage of 131 I, histological changes after the irradiation of 131 I, sites of thyroid cancer, and the relationship between 131 I therapy and the occurrence time of thyroid cancer were also considered. (Tsunoda, M.)

  10. Capsule endoscopy in the diagnosis of Crohn’s disease

    Directory of Open Access Journals (Sweden)

    Niv Y

    2013-05-01

    Full Text Available Yaron NivDepartment of Gastroenterology, Rabin Medical Center, Tel Aviv University, Petah Tikva, IsraelAbstract: Crohn’s disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn’s disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn’s disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn’s disease. Recently, we have developed and validated the Capsule Endoscopy Crohn’s Disease Activity Index (also known as the Niv score for Crohn’s disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn’s ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing

  11. Capsule Development and Utilization for Material Irradiation Tests

    International Nuclear Information System (INIS)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N.

    2003-05-01

    The objective of this project was to establish basic capsule irradiation technology using the multi-purpose research reactor [HANARO] to eventually support national R and D projects of advanced fuel and materials related to domestic nuclear power plants and next generation reactors. There are several national nuclear projects in KAERI, which require several irradiation tests to investigate in-pile behavior of nuclear reactor fuel and materials for the R and D of several types of fuels such as advanced PWR and DUPIC fuels and for the R and D of structural materials such as RPV(reactor pressure vessel) steel, Inconel, zirconium alloy, and stainless steel. At the moment, internal and external researchers in institutes, industries and universities are interested in investigating the irradiation characteristics of materials using the irradiation facilities of HANARO. For these kinds of material irradiation tests, it is important to develop various capsules using our own techniques. The development of capsules requires several leading-edge technologies and our own experiences related to design and fabrication. In the second phase from April 1,2000 to March 31, 2003, the utilization technologies were developed using various sensors for the measurements of temperature, pressure and displacement, and instrumented capsule technologies for the required fuel irradiation tests were developed. In addition, the improvement of the existing capsule technologies and the development of an in-situ measurable creep capsule for specific purposes were done to meet the various requirements of users

  12. Crosslinking studies in gelatin capsules treated with formaldehyde and in capsules exposed to elevated temperature and humidity.

    Science.gov (United States)

    Ofner, C M; Zhang, Y E; Jobeck, V C; Bowman, B J

    2001-01-01

    Incomplete in vitro capsule shell dissolution and subsequent drug release problems have recently received attention. A modified USP dissolution method was used to follow capsule shell dissolution, and a 2,4,6-trinitrobenzenesulfonic acid (TNBS) assay was used to follow loss of epsilon-amino groups to study this shell dissolution problem postulated to be due to gelatin crosslinking. The dissolution problems were simulated using hard gelatin capsule (HGC) shells previously treated with formaldehyde to crosslink the gelatin. These methods were also used to study the effect of uncrosslinked HGC stored under stressed conditions (37 degrees C and 81% RH) with or without the presence of soft gelatin capsule shells (SGC). A 120 ppm formaldehyde treatment reduced gelatin shell dissolution to 8% within 45 min in water at 37 degrees C. A 200 ppm treatment reduced gelatin epsilon-amino groups to 83% of the original uncrosslinked value. The results also support earlier reports of non-amino group crosslinking by formaldehyde in gelatin. Under stressed conditions, HGC stored alone showed little change over 21 weeks. However, by 12 to 14 weeks, the HGC exposed to SGC showed a 23% decrease in shell dissolution and an 8% decrease in the number of epsilon-amino groups. These effects on the stressed HGC are ascribed to a volatile agent from SGC shells, most likely formaldehyde, that crosslinked nearby HGC shells. This report also includes a summary of the literature on agents that reduce gelatin and capsule shell dissolution and the possible mechanisms of this not-so-simple problem. Copyright 2001 Wiley-Liss, Inc. and the American Pharmaceutical Association J Pharm Sci 90: 79-88, 2001

  13. 36 CFR 406.131-406.139 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false [Reserved] 406.131-406.139 Section 406.131-406.139 Parks, Forests, and Public Property AMERICAN BATTLE MONUMENTS COMMISSION... BATTLE MONUMENTS COMMISSION §§ 406.131-406.139 [Reserved] ...

  14. Capsule-Fixated Intraocular Lens Implantation in Small Pupil Cases.

    Science.gov (United States)

    Schojai, Merita; Schultz, Tim; Burkhard Dick, H

    2017-08-01

    To describe a new technique for implantation of capsule-fixated intraocular lenses (IOLs) (FEMTIS; Oculentis, Berlin, Germany) in patients with small pupils. In 4 eyes with small pupils, an anterior capsule-fixated IOL was implanted into the capsular bag after femtosecond laser treatment. The two large and two small flaps of the IOL were elevated to the front of the iris and the anterior capsule. Finally, the iris was flipped over the flaps to ensure a fixation of the capsule inside of the capsulotomy. In all cases, the implantation of anterior capsule-fixated IOLs was possible. No complications occurred during surgery or within the first months after surgery. With the described technique, capsulefixated IOLs can be implanted in eyes with small pupil easily and safely. This type of IOL has great potential to improve the refractive outcome by better prediction of the postoperative IOL position and eliminating IOL rotation after cataract surgery. [J Refract Surg. 2017;33(8):568-570.]. Copyright 2017, SLACK Incorporated.

  15. Triggered Release from Polymer Capsules

    Energy Technology Data Exchange (ETDEWEB)

    Esser-Kahn, Aaron P. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Odom, Susan A. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Sottos, Nancy R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Materials Science and Engineering; White, Scott R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Aerospace Engineering; Moore, Jeffrey S. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry

    2011-07-06

    Stimuli-responsive capsules are of interest in drug delivery, fragrance release, food preservation, and self-healing materials. Many methods are used to trigger the release of encapsulated contents. Here we highlight mechanisms for the controlled release of encapsulated cargo that utilize chemical reactions occurring in solid polymeric shell walls. Triggering mechanisms responsible for covalent bond cleavage that result in the release of capsule contents include chemical, biological, light, thermal, magnetic, and electrical stimuli. We present methods for encapsulation and release, triggering methods, and mechanisms and conclude with our opinions on interesting obstacles for chemically induced activation with relevance for controlled release.

  16. Approach to a system of removal of 131I of liquid discharges in a health unit of nuclear medicine using 127I as a reference standard

    International Nuclear Information System (INIS)

    Cruz, Emeterio; Mayorga, Manuel A.; Quiverio, Noelia M.; Villada, Julian D.

    2013-01-01

    The 131 I prepared as potassium iodide (KI) or sodium iodide (NaI) is given to patients to treat some diseases related to the thyroid gland, in doses of 15 to 30 mCi for hyperthyroidism and 100 to 300 mCi in treatments of thyroid cancer. Up to 80% of the administered activity is discarded by the patient through the body fluids over a period of 24 h; these radioactive waste must be controlled and accordingly the different countries based on radiological impact studies establishing maximum release rates. In Colombia, the Resolution 180005 2010 establishes 1000 Bq/day (2.7027x10 -5 Ci /day), 10000 Bq/month (2.7027x10 -4 mCi/month) or 100000 Bq/year (2.7027x10 -3 mCi/year), this restriction requires implementing waste management methods generated by patients before discharge to the sewage networks. The method of retention of these wastes through tanks, without any treatment generates a high potential risk, therefore, this study shows three alternatives to remove the 131 I in the amount of waste liquids, to generate a small solid residue in secure containers, allowing pouring fluids with radioactive traces without exceeding the limits. The sizing of the system applicable to nuclear medicine services depends on the workload of the service and combines the three methods described here by a control system, which does not require the direct intervention of staff, optimizing safety and radiation protection in the service. (author)

  17. What we have learned and what to expect from capsule endoscopy.

    Science.gov (United States)

    Adler, Samuel N; Bjarnason, Ingvar

    2012-10-16

    Capsule endoscopy was conceived by Gabriel Iddan and Paul Swain independently two decades ago. These applications include but are not limited to Crohn's disease of the small bowel, occult gastrointestinal bleeding, non steroidal anti inflammatory drug induced small bowel disease, carcinoid tumors of the small bowel, gastro intestinal stromal tumors of the small bowel and other disease affecting the small bowel. Capsule endoscopy has been compared to traditional small bowel series, computerized tomography studies and push enteroscopy. The diagnostic yield of capsule endoscopy has consistently been superior in the diagnosis of small bowel disease compared to the competing methods (small bowel series, computerized tomography, push enteroscopy) of diagnosis. For this reason capsule endoscopy has enjoyed a meteoric success. Image quality has been improved with increased number of pixels, automatic light exposure adaptation and wider angle of view. Further applications of capsule endoscopy of other areas of the digestive tract are being explored. The increased transmission rate of images per second has made capsule endoscopy of the esophagus a realistic possibility. Technological advances that include a double imager capsule with a nearly panoramic view of the colon and a variable frame rate adjusted to the movement of the capsule in the colon have made capsule endoscopy of the colon feasible. The diagnostic rate for the identification of patients with polyps equal to or larger than 6 mm is high. Future advances in technology and biotechnology will lead to further progress. Capsule endoscopy is following the successful modern trend in medicine that replaces invasive tests with less invasive methodology.

  18. 46 CFR 131.940 - Marine sanitation device.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Marine sanitation device. 131.940 Section 131.940... Miscellaneous § 131.940 Marine sanitation device. Each vessel with installed toilet facilities must have a marine sanitation device in compliance with 33 CFR part 159. ...

  19. Molecular epidemiology and virulence of Escherichia coli O16:H5-ST131: comparison with H30 and H30-Rx subclones of O25b:H4-ST131.

    Science.gov (United States)

    Dahbi, Ghizlane; Mora, Azucena; Mamani, Rosalia; López, Cecilia; Alonso, María Pilar; Marzoa, Juan; Blanco, Miguel; Herrera, Alexandra; Viso, Susana; García-Garrote, Fernando; Tchesnokova, Veronika; Billig, Mariya; de la Cruz, Fernando; de Toro, María; González-López, Juan José; Prats, Guillermo; Chaves, Fernando; Martínez-Martínez, Luis; López-Cerezo, Lorena; Denamur, Erick; Blanco, Jorge

    2014-11-01

    The present study was carried out to evaluate the prevalence of the clonal subgroup O16:H5-ST131 and the H30 and H30-Rx subclones among E. coli isolates causing extraintestinal infections and to know their virulence potential. The ST131 clonal group accounted for 490 (16%) of the 2995 isolates obtained from clinical samples in five Spanish hospitals during the study period (2005-2012). Among those 490 ST131 isolates, 456 belonged to serotype O25b:H4, 27 to O16:H5 and seven were O-non-typeable:H4 (ONT:H4). All 27 O16:H5 isolates showed fimH41, whereas fimH30 and fimH22 alleles were the most frequently detected among O25b:H4 isolates. The majority (381/490; 78%) of ST131 isolates belonged to H30 subclone, and 302 of 381 (79%) H30 isolates belonged to the H30-Rx subclone. Of the 27 O16:H5 isolates, 48% produced CTX-M-14; however, none produced CTX-M-15. In contrast, 46% of O25b:H4 isolates produced CTX-M-15 while only 2% produced CTX-M-14. More than a half of the O16:H5 isolates (56%) showed the ExPEC status which was significantly more prevalent within O25b:H4 isolates (81%) (P<0.01), especially among H30-Rx (97%) isolates. In the present study, a modified virotype scheme was applied within which approximately half (52%) of the O16:H5 isolates showed the C1 specific virotype. Despite their low virulence-gene score (mean of virulence genes 6.4 versus 8.5 in O25b:H4 isolates), six out of the 10 O16:H5 isolates assayed showed high virulence in the mouse model of sepsis (killed 90-100% of mice challenged). Furthermore, four O16:H5 isolates of virotypes A and C1, carrying K2 variant of group II capsule, showed lethality at 24h. Thus, certain O16:H5 fimH41 isolates show a similar in vivo virulence to that reported with the highly virulent O25b:H4 H30-Rx isolates (Mora et al., PLOS ONE 2014, e87025), supporting their potential virulence for humans. Copyright © 2014 Elsevier GmbH. All rights reserved.

  20. Baseline quantity of 131I, 137Cs, 134Cs and 40K in urinary excretions from Thai people and internal exposure dose

    Science.gov (United States)

    Peekhunthod, D.; Bangvirunrak, J.; Sansakon, S.; Nukultham, A.; Pukkhaw, T.

    2017-06-01

    Today, sealed and unsealed radioactive materials have been used in Thailand for various purposes such as medical, agricultural and industrial applications. There is a growing trend in the use of radioactive materials. Moreover, neighboring countries are planning to construct and operate nuclear power plants. In case of nuclear power plant accidents, radioactive releases in environment and intakes into human body by inhalation and ingestion causing long term health effects. This research aims to determine the radiation baseline quantity of interested relevant radionuclides such as 131I, 137Cs, 134Cs as well as a natural radionuclide, 40K in urine samples of Thai people by gamma spectrometry. Two types of detectors (NaI and HpGe detectors) are calibrated by mixed radionuclide standards of 109Cd, 57Co, 133Ba, 54Mn, 137Cs and 60Co, (energy range from 88 to 1,331 keV). 720 urine samples are collected over a 24 hour period from Thai volunteers with the age older than 18 years old, who lived in eight locations of Thailand. To reduce the effect of geometric difference, 30 ml of urine samples are prepared for counting measurement and efficiency determination. The radiation baseline quantity of 131I, 137Cs, 134Cs and 40K in 30 ml of urine samples are 0.37±0.09, 0.63±0.13, 0.39±0.08 and 7.84±1.63 Bq, respectively. Based on the assumption of intake (50% of the intake by ingestion and 50% of the intake by inhalation), internal dose for members of public are assessed. The committed dose equivalent due to an intake of 131I, 137Cs, 134Cs and 40K are 2.36E-03±1.66-03, 1.15E-01±8.61E-02, 1.16E-01±7.77E-02, 9.44E-01±3.56E-01 mSv per year, respectively.

  1. Measurement of the Dose to the Family Members Taking Care of Thyroid Cancer Patients Undergoing I-131 Therapy in Nuclear Medicine Using TLD-100.

    Science.gov (United States)

    Zehtabian, M; Dehghan, N; Danaei Ghazanfarkhani, M; Haghighatafshar, M; Sina, S

    2017-05-01

    The family members or friends of the patients undergoing treatment using radioiodine in nuclear medicine are inevitably exposed to ionization radiation. The purpose of this study is measurement of the dose received by the people taking care of the thyroid cancer patients treated by 131I. For this purpose, the dose amounts received by 29 people accompanying patients were measured using thermoluminescence dosimeters. A badge containing three TLD-100 chips was given to each caregiver. The people were asked to wear the badges for 24 days, when they are taking care of the patients. Finally the dose to each person was estimated by averaging the readings of the three TLDs. The measured dose amounts to the people were compared with the recommendations of international commitions. According to the results obtained in this study, the amounts of dose received by the caregivers were between 0.03 and 0.38 mSv, with the average of 0.12 mSv. By comparison of the results of this study with the recommendations of International Commission on Radiological Protection (ICRP), it can be observed that the dose to family members of the patients is less than the dose constraints. However, it is recommended that the caregivers be aware of the radiation protection principles in order to reduce their dose. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. 9 CFR 3.131 - Sanitation.

    Science.gov (United States)

    2010-01-01

    ... Warmblooded Animals Other Than Dogs, Cats, Rabbits, Hamsters, Guinea Pigs, Nonhuman Primates, and Marine... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sanitation. 3.131 Section 3.131 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE ANIMAL...

  3. Preliminary study of the distribution of dose in patients with Graves disease undergoing examination of uptake of iodine-131 using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Schwarcke, Marcelo; Marques, Tatiana; Alva, Mirko; Baffa, Oswaldo; Nicolucci, Patricia

    2009-01-01

    Patients with Graves' disease have a high hormonal disorder, which causes the change of behavior in society. One way to treat this disease is the use of doses of Iodine-131, requiring that the patient carries out the examination of uptake of 131 I estimates for completion of the activity to be administered. Using these data capture and compared with the simulated data using the Monte Carlo code Penelope is possible to determine a distribution of dose to the region surrounding the thyroid. As noted the difference between the simulated values and the experimentally obtained were 10.36%, thus showing the code of simulation for accurate determination of absorbed dose in tissue near the thyroid. (author)

  4. Safety evaluation for packaging (onsite) singly encapsulated cesium chloride capsules

    International Nuclear Information System (INIS)

    Smyth, W.W.

    1997-01-01

    Three nonstandard Waste Encapsulation and Storage Facility (WESF) cesium chloride capsules are being shipped from WESF (225B building) to the 324 building. They would normally be shipped in the Beneficial Uses Shipping System (BUSS) cask under its US Department of Energy (DOE) license (DOE 1996), but these capsules are nonstandard: one has a damaged or defective weld in the outer layer of encapsulation, and two have the outer encapsulation removed. The 3 capsules, along with 13 other capsules, will be overpacked in the 324 building to meet the requirements for storage in WESF's pool

  5. 45 CFR 2490.131-2490.139 - [Reserved

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false [Reserved] 2490.131-2490.139 Section 2490.131-2490.139 Public Welfare Regulations Relating to Public Welfare (Continued) JAMES MADISON MEMORIAL... CONDUCTED BY THE JAMES MADISON MEMORIAL FELLOWSHIP FOUNDATION §§ 2490.131-2490.139 [Reserved] ...

  6. Capsule shields the function of short bacterial adhesins

    DEFF Research Database (Denmark)

    Schembri, Mark; Dalsgaard, D.; Klemm, Per

    2004-01-01

    Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can...

  7. Toward an integrated model of capsule regulation in Cryptococcus neoformans.

    Directory of Open Access Journals (Sweden)

    Brian C Haynes

    2011-12-01

    Full Text Available Cryptococcus neoformans is an opportunistic fungal pathogen that causes serious human disease in immunocompromised populations. Its polysaccharide capsule is a key virulence factor which is regulated in response to growth conditions, becoming enlarged in the context of infection. We used microarray analysis of cells stimulated to form capsule over a range of growth conditions to identify a transcriptional signature associated with capsule enlargement. The signature contains 880 genes, is enriched for genes encoding known capsule regulators, and includes many uncharacterized sequences. One uncharacterized sequence encodes a novel regulator of capsule and of fungal virulence. This factor is a homolog of the yeast protein Ada2, a member of the Spt-Ada-Gcn5 Acetyltransferase (SAGA complex that regulates transcription of stress response genes via histone acetylation. Consistent with this homology, the C. neoformans null mutant exhibits reduced histone H3 lysine 9 acetylation. It is also defective in response to a variety of stress conditions, demonstrating phenotypes that overlap with, but are not identical to, those of other fungi with altered SAGA complexes. The mutant also exhibits significant defects in sexual development and virulence. To establish the role of Ada2 in the broader network of capsule regulation we performed RNA-Seq on strains lacking either Ada2 or one of two other capsule regulators: Cir1 and Nrg1. Analysis of the results suggested that Ada2 functions downstream of both Cir1 and Nrg1 via components of the high osmolarity glycerol (HOG pathway. To identify direct targets of Ada2, we performed ChIP-Seq analysis of histone acetylation in the Ada2 null mutant. These studies supported the role of Ada2 in the direct regulation of capsule and mating responses and suggested that it may also play a direct role in regulating capsule-independent antiphagocytic virulence factors. These results validate our experimental approach to dissecting

  8. Monitoring of garbage with a 5x5NaI (Tl) detector

    International Nuclear Information System (INIS)

    Cortes P, A.; Becerril V, A.; Angeles C, A.

    1991-12-01

    So far in that is carried out the first reload of nuclear fuel in the LVC, the monitoring of garbage has been carried out using monitors trade mark Eberline model RM 14. The procedure consists in manually monitoring each object and to separate of the considered 'clean' garbage the objects considered as contaminated, which register greater or equal counts to 100 cpm. This way to process was adequate under normal operation conditions, but not in the operation rhythm that implies a bigger maintenance since the time required for monitoring from 5 to 10 kg. of garbage is of the order of 0.5 hours and the production rhythm of this it ends up being a lot but high. Due to this necessity it was thought about the problem of looking by a more efficient monitoring method. In this work a method that uses a detector of NaI (Tl) of 5 x 5 inches is discussed. (Author)

  9. Toxicity of upfront {sup 131}I-metaiodobenzylguanidine ({sup 131}I-MIBG) therapy in newly diagnosed neuroblastoma patients: a retrospective analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bleeker, Gitta; Schoot, Reineke A.; Caron, Huib N.; Kraker, Jan de; Tytgat, Godelieve A. [Emma Children' s Hospital, Academic Medical Centre (AMC), Department of Paediatric Oncology, PO Box 22700, Amsterdam (Netherlands); Hoefnagel, Cees A. [National Cancer Institute (NKI-AvL), Department of Nuclear Medicine, Amsterdam (Netherlands); Eck, Berthe L. van [Academic Medical Centre (AMC), Department of Nuclear Medicine, Amsterdam (Netherlands)

    2013-10-15

    In the treatment of patients with high-risk neuroblastoma, different doses of {sup 131}I-metaiodobenzylguanidine ({sup 131}I-MIBG) are administered at different time points during treatment. Toxicity, mainly haematological (thrombocytopenia), from {sup 131}I-MIBG therapy is known to occur in extensively chemotherapy pretreated neuroblastoma patients. Up to now, acute toxicity from {sup 131}I-MIBG as initial treatment has never been studied in a large cohort. The aim of this retrospective study was to document acute toxicity related to upfront {sup 131}I-MIBG. All neuroblastoma patients (stages 1-4 and 4S) treated upfront with {sup 131}I-MIBG at the Emma Children's Hospital, Academic Medical Centre (1992 - 2008) were included in this retrospective analysis. The acute toxicity (during therapy) and short-term toxicity (1st month following therapy) of the first two {sup 131}I-MIBG therapies were studied. Of 66 patients (34 boys, 32 girls; median age 2.2 years, range 0.1 - 9.4 years), 49 had stage 4 disease, 5 stage 4S, 6 stage 3, 1 stage 2 and 5 stage 1. The median first dose was 441 MBq/kg (range 157 - 804 MBq/kg). The median second dose was 328 MBq/kg (range 113 - 727 MBq/kg). The most frequently observed symptoms were nausea and vomiting (21 %, maximum grade II). The main toxicity was grade IV haematological, occurring only in stage 4 patients, after the first and second {sup 131}I-MIBG therapies: anaemia (5 % and 4 %, respectively), leucocytopenia (3 % and 4 %) and thrombocytopenia (2 % and 4 %). No stem cell rescue was needed. The main acute toxicity observed was haematological followed by nausea and vomiting. One patient developed posterior reversible encephalopathy syndrome during {sup 131}I-MIBG therapy, possibly related to {sup 131}I-MIBG. We consider {sup 131}I-MIBG therapy to be a safe treatment modality. (orig.)

  10. Non-destructive tests of capsules for JMTR irradiation examination

    International Nuclear Information System (INIS)

    Tanaka, Hidetaka; Nagao, Yoshiharu; Sato, Masashi; Osawa, Kenji

    2007-03-01

    Irradiation examination are increasing in advanced irradiation research for accurate prediction control and evaluation of irradiation parameter such as neutron fluence, etc. by using JMTR. Irradiation capsule internals are therefore structurally complicated recently. This report described the procedure of non destructive tests such as radiographic test, penetrant test, ultrasonic test, etc. for inspection of irradiation capsules in JMTR, and the result of Test-case of confirmation procedure for internal parts of irradiation capsules. (author)

  11. Regional Variation Is Present in Elbow Capsules after Injury

    OpenAIRE

    Germscheid, Niccole M.; Hildebrand, Kevin A.

    2006-01-01

    Myofibroblast numbers and α-smooth muscle actin expression are increased in anterior joint capsules of patients with posttraumatic elbow contractures. The purpose of our study was to determine whether these changes occur regionally or throughout the entire joint capsule. We hypothesized that the α-smooth muscle actin mRNA expression and the myofibroblast numbers in posterior joint capsules would be elevated in elbows obtained from patients with posttraumatic joint contractures compared with j...

  12. 46 CFR 131.920 - Level of manning.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Level of manning. 131.920 Section 131.920 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.920 Level of manning. Each vessel must carry the personnel required by the Certificate of...

  13. SATCAP-C : a program for thermal hydraulic design of pressurized water injection type capsule

    International Nuclear Information System (INIS)

    Harayama, Yasuo; Someya, Hiroyuki; Asoh, Tomokazu; Niimi, Motoji

    1992-10-01

    There are capsules called 'Pressure Water Injection Type Capsule' as a kind of irradiation devices at the Japan Materials Testing Reactor (JMTR). A type of the capsules is a 'Boiling Water Capsule' (usually named BOCA). The other type is a 'Saturated Temperature Capsule' (named SATCAP). When the water is kept at a constant pressure, the water temperature does not become higher than the saturated temperature so far as the water does not fully change to steam. These type capsules are designed on the basis of the conception of applying the water characteristic to the control of irradiation temperature of specimens in the capsules. In designing of the capsules in which the pressurized water is injected, thermal performances have to be understood as exactly as possible. It is not easy however to predict thermal performances such as axially temperature distribution of water injected in the capsule, because there are heat-sinks at both side of inner and outer of capsule casing as the result that the water is fluid. Then, a program (named SATCAP-C) for the BOCA and SATCAP was compiled to grasp the thermal performances in the capsules and has been used the design of the capsules and analysis of the data obtained from some actual irradiation capsules. It was confirmed that the program was effective in thermal analysis for the capsules. The analysis found out the values for heat transfer coefficients at various surfaces of capsule components and some thermal characteristics of capsules. (author)

  14. Decreased uptake after fractionated ablative doses of iodine-131

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Hurng-Sheng [Show Chwan Memorial Hospital, Department of Surgery, Changhua, Taiwan (Taiwan); Hseu, Huey-Herng [Taichung Veterans General Hospital, Department of Medical Education and Research, Taichung (Taiwan); Lin, Wan-Yu; Wang, Shyh-Jen [Taichung Veterans General Hospital, Department of Nuclear Medicine, Taichung, Taiwan (Taiwan); Liu, Yao-Chi [Department of Surgery, General Surgery, National Defense Medical Center, Taipe (Taiwan)

    2005-02-01

    In an attempt to obviate the necessity for hospitalisation, the ablative dose of {sup 131}I in the treatment of thyroid cancer is divided into two or three fractions at weekly intervals in some hospitals with no special bed for {sup 131}I treatment. Thyroid stunning has been observed in patients receiving a {sup 131}I dose between 74 and 370 MBq (2-10 mCi). However, the influence of {sup 131}I uptake after administration of a higher dose, such as 1,110-1,850 MBq of {sup 131}I, has never been reported. In this study, we evaluated the degree of reduction in {sup 131}I uptake after patients received 1,480 MBq of {sup 131}I and evaluated the clinical value of fractionated ablative doses of {sup 131}I. Thirty-five patients with functional thyroid cancer received a total of 4,440 MBq (120 mCi) of {sup 131}I which was divided into three fractions administered at weekly intervals. In all patients two {sup 131}I whole-body scans were performed. The first scan was performed directly prior to the second dose of {sup 131}I (7 days after the first administration of {sup 131}I), and the second scan was performed 7 days after the second administration of {sup 131}I and directly prior to the third administration. Regions of interest including the neck and lungs were drawn to calculate the uptake of {sup 131}I in the thyroid remnant and possible cervical lymph node and lung metastases. The mean uptake of {sup 131}I was 2.73% 7 days after the first administration, and decreased significantly to 0.26% 7 days after the second administration. The mean decrease was as high as 80.7%. The decrease in {sup 131}I uptake was significant in all patients except the two with lung metastases. In the two patients with lung metastases, no definite evidence of decreased uptake was noted; the uptake of {sup 131}I in the lung metastases even increased on the second {sup 131}I image in one of these patients. After administration of 1,480 MBq of {sup 131}I, the decreased uptake was significant in all

  15. Simulations of indirectly driven gas-filled capsules at the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Weber, S. V.; Casey, D. T.; Eder, D. C.; Pino, J. E.; Smalyuk, V. A.; Remington, B. A.; Rowley, D. P.; Yeamans, C. B.; Tipton, R. E.; Barrios, M.; Benedetti, R.; Berzak Hopkins, L.; Bleuel, D. L.; Bond, E. J.; Bradley, D. K.; Caggiano, J. A.; Callahan, D. A.; Cerjan, C. J.; Clark, D. S.; Divol, L. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); and others

    2014-11-15

    Gas-filled capsules imploded with indirect drive on the National Ignition Facility have been employed as symmetry surrogates for cryogenic-layered ignition capsules and to explore interfacial mix. Plastic capsules containing deuterated layers and filled with tritium gas provide a direct measure of mix of ablator into the gas fuel. Other plastic capsules have employed DT or D{sup 3}He gas fill. We present the results of two-dimensional simulations of gas-filled capsule implosions with known degradation sources represented as in modeling of inertial confinement fusion ignition designs; these are time-dependent drive asymmetry, the capsule support tent, roughness at material interfaces, and prescribed gas-ablator interface mix. Unlike the case of cryogenic-layered implosions, many observables of gas-filled implosions are in reasonable agreement with predictions of these simulations. Yields of TT and DT neutrons as well as other x-ray and nuclear diagnostics are matched for CD-layered implosions. Yields of DT-filled capsules are over-predicted by factors of 1.4–2, while D{sup 3}He capsule yields are matched, as well as other metrics for both capsule types.

  16. Escherichia coli ST131, an Intriguing Clonal Group

    Science.gov (United States)

    Bertrand, Xavier; Madec, Jean-Yves

    2014-01-01

    SUMMARY In 2008, a previously unknown Escherichia coli clonal group, sequence type 131 (ST131), was identified on three continents. Today, ST131 is the predominant E. coli lineage among extraintestinal pathogenic E. coli (ExPEC) isolates worldwide. Retrospective studies have suggested that it may originally have risen to prominence as early as 2003. Unlike other classical group B2 ExPEC isolates, ST131 isolates are commonly reported to produce extended-spectrum β-lactamases, such as CTX-M-15, and almost all are resistant to fluoroquinolones. Moreover, ST131 E. coli isolates are considered to be truly pathogenic, due to the spectrum of infections they cause in both community and hospital settings and the large number of virulence-associated genes they contain. ST131 isolates therefore seem to contradict the widely held view that high levels of antimicrobial resistance are necessarily associated with a fitness cost leading to a decrease in pathogenesis. Six years after the first description of E. coli ST131, this review outlines the principal traits of ST131 clonal group isolates, based on the growing body of published data, and highlights what is currently known and what we need to find out to provide public health authorities with better information to help combat ST131. PMID:24982321

  17. The first capsule implosion experiments on Orion

    International Nuclear Information System (INIS)

    Garbett, W J; Horsfield, C J; Gales, S G; Leatherland, A E; Rubery, M S; Coltman, J E; Meadowcroft, A E; Rice, S J; Simons, A J; Woolhead, V E

    2016-01-01

    Direct drive capsule implosions are being developed on the Orion laser at AWE as a platform for ICF and HED physics experiments. The Orion facility combines both long pulse and short-pulse beams, making it well suited for studying the physics of alternative ignition approaches. Orion implosions also provide the opportunity to study aspects of polar direct drive. Limitations on drive symmetry from the relatively small number of laser beams makes predictive modelling of the implosions challenging, resulting in some uncertainty in the expected capsule performance. Initial experiments have been fielded to evaluate baseline capsule performance and inform future design optimization. Highly promising DD fusion neutron yields in excess of 10 9 have been recorded. Results from the experiments are presented alongside radiation-hydrocode modelling. (paper)

  18. Residual mercury content and leaching of mercury and silver from used amalgam capsules.

    Science.gov (United States)

    Stone, M E; Pederson, E D; Cohen, M E; Ragain, J C; Karaway, R S; Auxer, R A; Saluta, A R

    2002-06-01

    The objective of this investigation was to carry out residual mercury (Hg) determinations and toxicity characteristic leaching procedure (TCLP) analysis of used amalgam capsules. For residual Hg analysis, 25 capsules (20 capsules for one brand) from each of 10 different brands of amalgam were analyzed. Total residual Hg levels per capsule were determined using United States Environmental Protection Agency (USEPA) Method 7471. For TCLP analysis, 25 amalgam capsules for each of 10 brands were extracted using a modification of USEPA Method 1311. Hg analysis of the TCLP extracts was done with USEPA Method 7470A. Analysis of silver (Ag) concentrations in the TCLP extract was done with USEPA Method 6010B. Analysis of the residual Hg data resulted in the segregation of brands into three groups: Dispersalloy capsules, Group A, retained the most Hg (1.225 mg/capsule). These capsules were the only ones to include a pestle. Group B capsules, Valliant PhD, Optaloy II, Megalloy and Valliant Snap Set, retained the next highest amount of Hg (0.534-0.770 mg/capsule), and were characterized by a groove in the inside of the capsule. Group C, Tytin regular set double-spill, Tytin FC, Contour, Sybraloy regular set, and Tytin regular set single-spill retained the least amount of Hg (0.125-0.266 mg/capsule). TCLP analysis of the triturated capsules showed Sybraloy and Contour leached Hg at greater than the 0.2 mg/l Resource Conservation and Recovery Act (RCRA) limit. This study demonstrated that residual mercury may be related to capsule design features and that TCLP extracts from these capsules could, in some brands, exceed RCRA Hg limits, making their disposal problematic. At current RCRA limits, the leaching of Ag is not a problem.

  19. [Exploring the clinical characters of Shugan Jieyu capsule through text mining].

    Science.gov (United States)

    Pu, Zheng-Ping; Xia, Jiang-Ming; Xie, Wei; He, Jin-Cai

    2017-09-01

    The study was main to explore the clinical characters of Shugan Jieyu capsule through text mining. The data sets of Shugan Jieyu capsule were downloaded from CMCC database by the method of literature retrieved from May 2009 to Jan 2016. Rules of Chinese medical patterns, diseases, symptoms and combination treatment were mined out by data slicing algorithm, and they were demonstrated in frequency tables and two dimension based network. Then totally 190 literature were recruited. The outcomess suggested that SC was most frequently correlated with liver Qi stagnation. Primary depression, depression due to brain disease, concomitant depression followed by physical diseases, concomitant depression followed by schizophrenia and functional dyspepsia were main diseases treated by Shugan Jieyu capsule. Symptoms like low mood, psychic anxiety, somatic anxiety and dysfunction of automatic nerve were mainy relieved bv Shugan Jieyu capsule.For combination treatment. Shugan Jieyu capsule was most commonly used with paroxetine, sertraline and fluoxetine. The research suggested that syndrome types and mining results of Shugan Jieyu capsule were almost the same as its instructions. Syndrome of malnutrition of heart spirit was the potential Chinese medical pattern of Shugan Jieyu capsule. Primary comorbid anxiety and depression, concomitant comorbid anxiety and depression followed by physical diseases, and postpartum depression were potential diseases treated by Shugan Jieyu capsule.For combination treatment, Shugan Jieyu capsule was most commonly used with paroxetine, sertraline and fluoxetine. Copyright© by the Chinese Pharmaceutical Association.

  20. The double capsules in macro-textured breast implants.

    Science.gov (United States)

    Giot, Jean-Philippe; Paek, Laurence S; Nizard, Nathanael; El-Diwany, Mostafa; Gaboury, Louis A; Nelea, Monica; Bou-Merhi, Joseph S; Harris, Patrick G; Danino, Michel A

    2015-10-01

    Breast implants are amongst the most widely used types of permanent implants in modern medicine and have both aesthetic and reconstructive applications with excellent biocompatibility. The double capsule is a complication associated with textured prostheses that leads to implant displacement; however, its etiology has yet to be elucidated. In this study, 10 double capsules were sampled from breast expander implants for in-depth analysis; histologically, the inner capsular layer demonstrated highly organized collagen in sheets with delamination of fibers. At the prosthesis interface (PI) where the implant shell contacts the inner capsular layer, scanning electron microscopy (SEM) revealed a thin layer which mirrored the three-dimensional characteristics of the implant texture; the external surface of the inner capsular layer facing the intercapsular space (ICS) was flat. SEM examination of the inner capsule layer revealed both a large bacterial presence as well as biofilm deposition at the PI; a significantly lower quantity of bacteria and biofilm were found at the ICS interface. These findings suggest that the double capsule phenomenon's etiopathogenesis is of mechanical origin. Delamination of the periprosthetic capsule leads to the creation of the ICS; the maintained separation of the 2 layers subsequently alters the biostability of the macro-textured breast implant. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. 28 CFR 39.131-39.139 - [Reserved

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false [Reserved] 39.131-39.139 Section 39.131-39.139 Judicial Administration DEPARTMENT OF JUSTICE ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE DEPARTMENT OF JUSTICE §§ 39.131-39.139 [Reserved] ...

  2. 33 CFR 25.131 - Delegation of authority.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Delegation of authority. 25.131 Section 25.131 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY GENERAL CLAIMS General § 25.131 Delegation of authority. (a) The Chief Counsel is delegated the following authority: (1...

  3. 21 CFR 131.120 - Sweetened condensed milk.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Sweetened condensed milk. 131.120 Section 131.120 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION MILK AND CREAM Requirements for Specific Standardized Milk and Cream § 131.120...

  4. 9 CFR 2.131 - Handling of animals.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Handling of animals. 2.131 Section 2.131 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE ANIMAL WELFARE REGULATIONS Miscellaneous § 2.131 Handling of animals. (a) All licensees who maintain wild...

  5. Versatile Loading of Diverse Cargo into Functional Polymer Capsules.

    Science.gov (United States)

    Richardson, Joseph J; Maina, James W; Ejima, Hirotaka; Hu, Ming; Guo, Junling; Choy, Mei Y; Gunawan, Sylvia T; Lybaert, Lien; Hagemeyer, Christoph E; De Geest, Bruno G; Caruso, Frank

    2015-02-01

    Polymer microcapsules are of particular interest for applications including self-healing coatings, catalysis, bioreactions, sensing, and drug delivery. The primary way that polymer capsules can exhibit functionality relevant to these diverse fields is through the incorporation of functional cargo in the capsule cavity or wall. Diverse functional and therapeutic cargo can be loaded into polymer capsules with ease using polymer-stabilized calcium carbonate (CaCO 3 ) particles. A variety of examples are demonstrated, including 15 types of cargo, yielding a toolbox with effectively 500+ variations. This process uses no harsh reagents and can take less than 30 min to prepare, load, coat, and form the hollow capsules. For these reasons, it is expected that the technique will play a crucial role across scientific studies in numerous fields.

  6. Recurrent thyrotoxicosis after I-131 induced hypothyroidism

    International Nuclear Information System (INIS)

    Liu, L.; Borowski, G.D.; Shtasel, P.; Rose, L.I.

    1984-01-01

    The first clinically and biochemically documented case of recurrent thyrotoxicosis after I-131 induced hypothyroidism in a patient with Graves' disease is reported. Two months after the administration of 9.2 mCi of I-131, the subject developed hypothyroidism. One month later, the patient became euthyroid. Then, nine months following ablation, the patient again developed thyrotoxicosis. A second dose of I-131 of 12.5 mCi was required to finally produce permanent hypothyroidism. This case illustrates the recurrence of hypothyroidism after what had seemed to have been adequate I-131 radiation

  7. Model of iodine metabolism in a T3-thyrotoxic patient undergoing I-131 therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ahuja, S.; Price, R.; Brill, A. B.; Dobyns, B. M.; Berman, M.

    1975-06-01

    Data on radioactivity in the thyroid, urine, serum, butanol-extractable iodine (BEI) and chromatographic fractionations of BEI, obtained during four I-131 therapeutic treatments of a T3-thyrotoxic patient, have been analyzed and simulated with the help of a 7-compartment model. Good fits to most of the data can be obtained with both the dose-independent and dose-dependent models. A model with 3 or 4 compartments, which provides adequate fits to iodine kinetic data in most euthyroid and hyperthyroid patients is not satisfactory in the case of this patient. Thus, to represent iodine metabolism during T3-thyrotoxicosis therapy, we find that it is necessary to provide for separate biochemical pathways for the BEI components as well as the butanol-insoluble compounds released by the thyroid gland. (auth)

  8. Molecular dynamics of polarizable point dipole models for molten NaI. Comparison with first principles simulations

    Directory of Open Access Journals (Sweden)

    Trullàs J.

    2011-05-01

    Full Text Available Molecular dynamics simulations of molten NaI at 995 K have been carried out using polarizable ion models based on rigid ion pair potentials to which the anion induced dipole polarization is added. The polarization is added in such a way that point dipoles are induced on the anions by both local electric field and deformation short-range damping interactions that oppose the electrically induced dipole moments. The structure and self-diffusion results are compared with those obtained by Galamba and Costa Cabral using first principles Hellmann-Feynman molecular dynamics simulations and using classical molecular dynamics of a shell model which allows only the iodide polarization

  9. Method of forming capsules containing a precise amount of material

    Science.gov (United States)

    Grossman, M.W.; George, W.A.; Maya, J.

    1986-06-24

    A method of forming a sealed capsule containing a submilligram quantity of mercury or the like, the capsule being constructed from a hollow glass tube, by placing a globule or droplet of the mercury in the tube. The tube is then evacuated and sealed and is subsequently heated so as to vaporize the mercury and fill the tube therewith. The tube is then separated into separate sealed capsules by heating spaced locations along the tube with a coiled heating wire means to cause collapse spaced locations there along and thus enable separation of the tube into said capsules. 7 figs.

  10. 11 CFR 100.131 - Testing the waters.

    Science.gov (United States)

    2010-01-01

    ... 11 Federal Elections 1 2010-01-01 2010-01-01 false Testing the waters. 100.131 Section 100.131 Federal Elections FEDERAL ELECTION COMMISSION GENERAL SCOPE AND DEFINITIONS (2 U.S.C. 431) Exceptions to Expenditures § 100.131 Testing the waters. (a) General exemption. Payments made solely for the purpose of...

  11. 47 CFR 87.131 - Power and emissions.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Power and emissions. 87.131 Section 87.131... Technical Requirements § 87.131 Power and emissions. The following table lists authorized emissions and... Authorized emission(s) 9 Maximum power 1 Aeronautical advisory VHF A3E 10 watts. 10 Aeronautical multicom VHF...

  12. Iodometric determination of ampicillin in proprietary capsules | Ejele ...

    African Journals Online (AJOL)

    The concentration of ampicillin in ampicillin capsule preparations purchased in Owerri main market, Imo State of Nigeria, was determined using the iodometric titration method. The results showed that the ampicillin concentrations in the capsules contained between 250 and 260 mg/cap of ampicillin trihydrate. Statistical ...

  13. Video-based measurements for wireless capsule endoscope tracking

    International Nuclear Information System (INIS)

    Spyrou, Evaggelos; Iakovidis, Dimitris K

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions. (paper)

  14. Video-based measurements for wireless capsule endoscope tracking

    Science.gov (United States)

    Spyrou, Evaggelos; Iakovidis, Dimitris K.

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions.

  15. Medical capsule robots: A renaissance for diagnostics, drug delivery and surgical treatment.

    Science.gov (United States)

    Mapara, Sanyat S; Patravale, Vandana B

    2017-09-10

    The advancements in electronics and the progress in nanotechnology have resulted in path breaking development that will transform the way diagnosis and treatment are carried out currently. This development is Medical Capsule Robots, which has emerged from the science fiction idea of robots travelling inside the body to diagnose and cure disorders. The first marketed capsule robot was a capsule endoscope developed to capture images of the gastrointestinal tract. Today, varieties of capsule endoscopes are available in the market. They are slightly larger than regular oral capsules, made up of a biocompatible case and have electronic circuitry and mechanisms to capture and transmit images. In addition, robots with diagnostic features such as in vivo body temperature detection and pH monitoring have also been launched in the market. However, a multi-functional unit that will diagnose and cure diseases inside the body has not yet been realized. A remote controlled capsule that will undertake drug delivery and surgical treatment has not been successfully launched in the market. High cost, inadequate power supply, lack of control over drug release, limited space for drug storage on the capsule, inadequate safety and no mechanisms for active locomotion and anchoring have prevented their entry in the market. The capsule robots can revolutionize the current way of diagnosis and treatment. This paper discusses in detail the applications of medical capsule robots in diagnostics, drug delivery and surgical treatment. In diagnostics, detailed analysis has been presented on wireless capsule endoscopes, issues associated with the marketed versions and their corresponding solutions in literature. Moreover, an assessment has been made of the existing state of remote controlled capsules for targeted drug delivery and surgical treatment and their future impact is predicted. Besides the need for multi-functional capsule robots and the areas for further research have also been

  16. 21 CFR 131.147 - Dry whole milk.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Dry whole milk. 131.147 Section 131.147 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION MILK AND CREAM Requirements for Specific Standardized Milk and Cream § 131.147 Dry whole milk. (a...

  17. 21 CFR 131.125 - Nonfat dry milk.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Nonfat dry milk. 131.125 Section 131.125 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION MILK AND CREAM Requirements for Specific Standardized Milk and Cream § 131.125 Nonfat dry milk. (a...

  18. 46 CFR 131.420 - Manning and supervision.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Manning and supervision. 131.420 Section 131.420 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Sufficiency and Supervision of Crew of Survival Craft § 131.420 Manning and supervision. (a) There must be enough trained persons aboard each survival craf...

  19. Bowman Capsulitis Predicts Poor Kidney Allograft Outcome in T Cell-Mediated Rejection.

    Science.gov (United States)

    Gallan, Alexander J; Chon, W James; Josephson, Michelle A; Cunningham, Patrick N; Henriksen, Kammi J; Chang, Anthony

    2018-02-28

    Acute T cell-mediated rejection (TCMR) is an important cause of renal allograft loss. The Banff classification for tubulointerstitial (type I) rejection is based on the extent of both interstitial inflammation and tubulitis. Lymphocytes may also be present between parietal epithelial cells and Bowman capsules in this setting, which we have termed "capsulitis." We conducted this study to determine the clinical significance of capsulitis. We identified 42 patients from the pathology archives at the University of Chicago with isolated Banff type I TCMR from 2010-2015. Patient demographic data, Banff classification, and graft outcome measurements were compared between capsulitis and non-capsulitis groups using Mann-Whitney U test. Capsulitis was present in 26 (62%), and was more frequently seen in Banff IB than IA TCMR (88% vs 44%, P=.01). Patients with capsulitis had a higher serum creatinine at biopsy (4.6 vs 2.9mg/dL, P=.04) and were more likely to progress to dialysis (42% vs 13%, P=.06) with fewer recovering their baseline serum creatinine (12% vs 38%, P=.08). Patients with both Banff IA TCMR and capsulitis have clinical outcomes similar or possibly worse than Banff IB TCMR compared to those with Banff IA and an absence of capsulitis. Capsulitis is an important pathologic parameter in the evaluation of kidney transplant biopsies with potential diagnostic, prognostic, and therapeutic implications in the setting of TCMR. Copyright © 2018. Published by Elsevier Inc.

  20. The effect of glicerol and sorbitol plasticizers toward disintegration time of phyto-capsules

    Science.gov (United States)

    Pudjiastuti, Pratiwi; Hendradi, Esti; Wafiroh, Siti; Harsini, Muji; Darmokoesoemo, Handoko

    2016-03-01

    The aim of research is determining the effect of glycerol and sorbitol toward the disintegration time of phyto-capsules, originated capsules from plant polysaccharides. Phyto-capsules were made from polysaccharides and 0.5% (v/v) of glycerol and sorbitol of each. The seven capsules of each were determined the disintegration time using Erweka disintegrator. The mean of disintegration time of phyto-capsules without plasticizers, with glycerol and sorbitol were 25'30"; 45'15" and 35'30" respectively. The color and colorless gelatin capsules showed the mean of disintegration time 7'30" and 2'35" respectively.

  1. Alginate/sodium caseinate aqueous-core capsules: a pH-responsive matrix.

    Science.gov (United States)

    Ben Messaoud, Ghazi; Sánchez-González, Laura; Jacquot, Adrien; Probst, Laurent; Desobry, Stéphane

    2015-02-15

    Alginate capsules have several applications. Their functionality depends considerably on their permeability, chemical and mechanical stability. Consequently, the creation of composite system by addition of further components is expected to control mechanical and release properties of alginate capsules. Alginate and alginate-sodium caseinate composite liquid-core capsules were prepared by a simple extrusion. The influence of the preparation pH and sodium caseinate concentration on capsules physico-chemical properties was investigated. Results showed that sodium caseinate influenced significantly capsules properties. As regards to the membrane mechanical stability, composite capsules prepared at pH below the isoelectric point of sodium caseinate exhibited the highest surface Young's modulus, increasing with protein content, explained by potential electrostatic interactions between sodium caseinate amino-groups and alginate carboxylic group. The kinetic of cochineal red A release changed significantly for composite capsules and showed a pH-responsive release. Sodium caseinate-dye mixture studied by absorbance and fluorescence spectroscopy confirmed complex formation at pH 2 by electrostatic interactions between sodium caseinate tryptophan residues and cochineal red sulfonate-groups. Consequently, the release mechanism was explained by membrane adsorption process. This global approach is useful to control release mechanism from macro and micro-capsules by incorporating guest molecules which can interact with the entrapped molecule under specific conditions. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Analysis of lomustine drug content in FDA-approved and compounded lomustine capsules.

    Science.gov (United States)

    KuKanich, Butch; Warner, Matt; Hahn, Kevin

    2017-02-01

    OBJECTIVE To determine the lomustine content (potency) in compounded and FDA-approved lomustine capsules. DESIGN Evaluation study. SAMPLE 2 formulations of lomustine capsules (low dose [7 to 11 mg] and high dose [40 to 48 mg]; 5 capsules/dose/source) from 3 compounders and from 1 manufacturer of FDA-approved capsules. PROCEDURES Lomustine content was measured by use of a validated high-pressure liquid chromatography method. An a priori acceptable range of 90% to 110% of the stated lomustine content was selected on the basis of US Pharmacopeia guidelines. RESULTS The measured amount of lomustine in all compounded capsules was less than the stated content (range, 59% to 95%) and was frequently outside the acceptable range (failure rate, 2/5 to 5/5). Coefficients of variation for lomustine content ranged from 4.1% to 16.7% for compounded low-dose capsules and from 1.1% to 10.8% for compounded high-dose capsules. The measured amount of lomustine in all FDA-approved capsules was slightly above the stated content (range, 104% to 110%) and consistently within the acceptable range. Coefficients of variation for lomustine content were 0.5% for low-dose and 2.3% for high-dose FDA-approved capsules. CONCLUSIONS AND CLINICAL RELEVANCE Compounded lomustine frequently did not contain the stated content of active drug and had a wider range of lomustine content variability than did the FDA-approved product. The sample size was small, and larger studies are needed to confirm these findings; however, we recommend that compounded veterinary formulations of lomustine not be used when appropriate doses can be achieved with FDA-approved capsules or combinations of FDA-approved capsules.

  3. Magnesium Ion Acts as a Signal for Capsule Induction in Cryptococcus neoformans.

    Science.gov (United States)

    Rathore, Sudarshan S; Raman, Thiagarajan; Ramakrishnan, Jayapradha

    2016-01-01

    Cryptococcal meningitis caused by Cryptococcus neoformans, is a common opportunistic neural infection in immunocompromised individuals. Cryptococcus meningitis is associated with fungal burden with larger capsule size in cerebrospinal fluid (CSF). To understand the role of CSF constituents in capsule enlargement, we have evaluated the effect of artificial CSF on capsule induction in comparison with various other capsule inducing media. Two different strains of C. neoformans, an environmental and a clinical isolates were used in the present study. While comparing the various capsule inducing media for the two different strains of C. neoformans, it was observed that the capsule growth was significantly increased when grown in artificial CSF at pH 5.5, temperature 34°C for ATCC C. neoformans and 37°C for Clinical C. neoformans and with an incubation period of 72 h. In addition, artificial CSF supports biofilm formation in C. neoformans. While investigating the individual components of artificial CSF, we found that Mg(2+) ions influence the capsule growth in both environmental and clinical strains of C. neoformans. To confirm our results we studied the expression of four major CAP genes namely, CAP10, CAP59, CAP60, and CAP64 in various capsule inducing media and in different concentrations of Mg(2+) and Ca(2+). Our results on gene expression suggest that, Mg(2+) does have an effect on CAP gene expression, which are important for capsule biosynthesis and virulence. Our findings on the role of Mg(2+) ion as a signal for capsule induction will promote a way to elucidate the control mechanisms for capsule biosynthesis in C. neoformans.

  4. Irradiation capsules VISA-2a-f, chapter VI

    International Nuclear Information System (INIS)

    Pavicevic, M.

    1962-01-01

    Irradiation capsules VISA-2a, b,c,d, and e were constructed in Saclay according to the drawings from Vinca and according to the demand of the experimentators. This chapter VI includes documentation for each type of capsule, review about each experiment within the VISA-2 project, the objective and purpose of the experiment as well as experimental device. Irradiation capsule VISA-2f was placed in the RA reactor core in September 1962. It was completely manufactured in Vinca including sample holders and leak tight shells. It will remain in the reactor core for about month in order to obtain the integral fast neutron flux [sr

  5. Some views on mechanical safety of capsules for radioactive waste

    International Nuclear Information System (INIS)

    Nilsson, F.

    1978-02-01

    Three different concepts for encapsulation of used nuclear fuel are discussed with respect to their mechanical safety. In the first concept the burnt out fuel elements are encapsulated into a copper capsule. The material properties of copper are discussed especially with reference to toughness and creep. A simple fracture mechanical analysis shows that the risk for direct fracture is negligible at the actual stress levels. The loads on the capsule are studied and are found to be normally less than 40 MPa (residual stresses). Transient loads that might arise in the handling of the capsule might however be dangerous to its integrity. The next concept is encapsulation of the fuel elements into a sintered aluminium oxide capsule. A fracture probability analysis based on Weibull's statistical fracture theory gives fracture probabilities that are acceptable. Extended studies of this concept, especially of the risk for delayed fracture, is recommended. The last concept is a Pb-Ti capsule for glassed refined fuel. An analysis of the relaxation of internal stresses is performed. The critical point of these capsules appears to be the welds on the titanium shell where the risk for a direct fracture is not neglibigle

  6. Behavior of Na131I and meta(131I) iodobenzylguanidine (MIBG) in municipal sewerage.

    Science.gov (United States)

    Fenner, F D; Martin, J E

    1997-08-01

    Behavior of 131I activity in primary sludge at the Ann Arbor, Michigan, Municipal Waste Water Treatment Plant was studied in relation to known radioiodine therapy events at the University of Michigan Hospital complex. The principal compounds administered are Na131I, which has widespread use, and meta (131I) iodobenzylguanidine (MIBG), which is a compound unique to the University of Michigan, although labeled antibodies and other forms are also used in therapy and research. The objectives of the study were to determine the environmental fate of such discharges and to determine radiation exposures to workers and the public when sludges are incinerated. Approximately 17% of the MIBG activity administered in a therapy was found in the primary sludge, whereas only 1.1% of the Na131I was in sludge. When land applied, the short half life of 131I in the sludge presents few radiological health concerns; however, incineration, which is done in winter months, is assumed to release organically bound 131I to the atmosphere. Radiation doses due to incineration of sludge containing measured concentrations were calculated for a maximally exposed worker to be 1.7 microSv (0.17 mrem) of which 0.48 microSv (0.048 mrem) was due to a 2-d upset condition. For a more typically exposed worker, and a member of the public, the committed effective dose equivalents were 1.2 microSv (0.12 mrem) and 0.06 microSv (0.006 mrem), respectively, for a 22-wk incineration period with release of all radioiodine in the sludge. Transport time to the treatment plant for radioiodine was found to be much longer than that of normal sewage, possibly due to organic material in sewer lines that absorb iodine. The residence time of radioiodine in the sewer also appears to be longer than expected; whether other radioactive materials are held up the same way is not known but chemical form is surely a factor.

  7. Slit-lamp Needling of the Anterior Capsule for Aqueous Misdirection After Hyaloido-zonulectomy and Iridectomy.

    Science.gov (United States)

    Mardelli, Pierre G; Mardelli, Marc E

    2018-04-01

    We present a case of persistent aqueous misdirection, after Ahmed glaucoma valve surgery, despite undergoing an anterior vitrectomy with hyaloido-zonulectomy and iridectomy. A 73-year-old female patient, 4 months after phacotrabeculectomy, was referred with persistent high intraocular pressure (IOP). Postoperatively, she developed aqueous misdirection with a flat anterior chamber (AC) but with an IOP of 15 mm Hg. On presentation, her AC was shallow with peripheral iris-cornea touch, and her IOP was 39 mm Hg. Posterior Nd:Yag capsulotomy with disruption of anterior hyaloid face partially deepened the AC. With failure of the trabeculectomy and high IOP, an Ahmed valve was placed. On the first operative day the AC was deep with an IOP of 10 mm Hg. On day 6 the patient presented with pain, flat AC, and an IOP of 10 mm Hg. Fundus examination revealed no choroidal effusion. Despite repeated reformation with viscoelastic, the AC failed to deepen. An anterior vitrectomy with hyaloido-zonulectomy was performed. Initially, the AC was deep, but, a few days later, it was flat. Multiple reformations and vitreous tap failed to keep the AC deep. A 30-G needle was passed at the slit lamp across the temporal cornea, iris, and anterior capsule into the anterior vitreous cavity. The needle was then partially withdrawn and used to create a space between the intraocular lens and anterior capsule. This immediately deepened the AC and remained so for the duration of follow-up (4 mo). Slit-lamp needling of the anterior lens capsule can be successfully performed to help resolve a persistent case of aqueous misdirection after anterior vitrectomy.

  8. The Antiphagocytic Activity of SeM of Streptococcus equi Requires Capsule.

    Science.gov (United States)

    Timoney, John F; Suther, Pranav; Velineni, Sridhar; Artiushin, Sergey C

    2014-01-01

    Resistance to phagocytosis is a crucial virulence property of Streptococcus equi (Streptococcus equi subsp. equi; Se), the cause of equine strangles. The contribution and interdependence of capsule and SeM to killing in equine blood and neutrophils were investigated in naturally occurring strains of Se. Strains CF32, SF463 were capsule and SeM positive, strains Lex90, Lex93 were capsule negative and SeM positive and strains Se19, Se1-8 were capsule positive and SeM deficient. Phagocytosis and killing of Se19, Se1-8, Lex90 and Lex93 in equine blood and by neutrophils suspended in serum were significantly (P ≤ 0.02) greater compared to CF32 and SF463. The results indicate capsule and SeM are both required for resistance to phagocytosis and killing and that the anti-phagocytic property of SeM is greatly reduced in the absence of capsule.

  9. Membrane support of accelerated fuel capsules for inertial fusion energy reactors

    International Nuclear Information System (INIS)

    Petzoldt, R.W.; Moir, R.W.

    1993-01-01

    The use of a thin membrane to suspend an (inertial fusion energy) fuel capsule in a holder for injection into a reactor chamber is investigated. Capsule displacement and membrane deformation angle are calculated for an axisymmetric geometry for a range of membrane strain and capsule size. This information is used to calculate maximum target accelerations. Membranes must be thin (perhaps of order one micron) to minimize their effect on capsule implosion symmetry. For example, a 5 μm thick cryogenic mylar membrane is calculated to allow 1,000 m/s 2 acceleration of a 3 mm radius, 100 mg capsule. Vibration analysis (for a single membrane support) shows that if membrane vibration is not deliberately minimized, allowed acceleration may be reduced by a factor of four. A two membrane alternative geometry would allow several times greater acceleration. Therefore, alternative membrane geometry's should be used to provide greater target acceleration potential and reduce capsule displacement within the holder (for a given membrane thickness)

  10. Experimental Investigation of the Spiral Structure of a Magnetic Capsule Endoscope

    Directory of Open Access Journals (Sweden)

    Wanan Yang

    2016-06-01

    Full Text Available Fitting a wireless capsule endoscope (WCE with a navigation feature can maximize its functional benefits. The rotation of a spiral-type capsule can be converted to translational motion. The study investigated how the spiral structure and rotational speed affected the capsule's translation speed. A hand-held instrument, including two permanent magnets, a stepper motor, a controller and a power supplier, were designed to generate rotational magnetic fields. The surfaces of custom-built permanent magnet rings magnetized radially were mounted in spiral lines with different lead angles and diameters, acting as mock-up capsules. The experimental results demonstrate that the rotational speed of the magnetic field and the spiral have significant effects on the translational speed of a capsule. The spiral line with a larger lead angle and the rotating magnetic field with a higher speed can change the capsule's rotation into a translational motion more efficiently in the intestine.

  11. Effect of Heat Flux on the Specimen Temperature of an LBE Capsule

    International Nuclear Information System (INIS)

    Kang, Y. H.; Park, S. J.; Cho, M. S.; Choo, K. N.; Lee, Y. S.

    2011-01-01

    For application of high-temperature irradiation tests in the HANARO reactor for Gen IV reactor material development, a number of newly designed LBE capsules have been investigated at KAERI since 2008. Recent study on heat transfer experiment of an LBE capsule with a single heater has shown that the specimen temperature of the mock-up increased linearly with an increase of heat input. The work highlighted only the heat transfer capability of an LBE capsule with a single heater as a simulated specimen in a liquid metal medium. Hence, a new LBE capsule with multi specimen sets has been designed and fabricated for the heat transfer experiment of an LBE capsule of 11M-01K. In this paper, a series of thermal analyses and heat transfer experiments for a newly designed LBE capsule was implemented to study the effect of an increase in the value of heat input and its influence on temperature distribution in the capsule mock-up

  12. A predictive mathematical model for the calculation of the final mass of Graves' disease thyroids treated with 131I

    Science.gov (United States)

    Traino, Antonio C.; Di Martino, Fabio; Grosso, Mariano; Monzani, Fabio; Dardano, Angela; Caraccio, Nadia; Mariani, Giuliano; Lazzeri, Mauro

    2005-05-01

    Substantial reductions in thyroid volume (up to 70-80%) after radioiodine therapy of Graves' hyperthyroidism are common and have been reported in the literature. A relationship between thyroid volume reduction and outcome of 131I therapy of Graves' disease has been reported by some authors. This important result could be used to decide individually the optimal radioiodine activity A0 (MBq) to administer to the patient, but a predictive model relating the change in gland volume to A0 is required. Recently, a mathematical model of thyroid mass reduction during the clearance phase (30-35 days) after 131I administration to patients with Graves' disease has been published and used as the basis for prescribing the therapeutic thyroid absorbed dose. It is well known that the thyroid volume reduction goes on until 1 year after therapy. In this paper, a mathematical model to predict the final mass of Graves' diseased thyroids submitted to 131I therapy is presented. This model represents a tentative explanation of what occurs macroscopically after the end of the clearance phase of radioiodine in the gland (the so-called second-order effects). It is shown that the final thyroid mass depends on its basal mass, on the radiation dose absorbed by the gland and on a constant value α typical of thyroid tissue. α has been evaluated based on a set of measurements made in 15 reference patients affected by Graves' disease and submitted to 131I therapy. A predictive equation for the calculation of the final mass of thyroid is presented. It is based on macroscopic parameters measurable after a diagnostic 131I capsule administration (0.37-1.85 MBq), before giving the therapy. The final mass calculated using this equation is compared to the final mass of thyroid measured 1 year after therapy administration in 22 Graves' diseased patients. The final masses calculated and measured 1 year after therapy are in fairly good agreement (R = 0.81). The possibility, for the physician, to decide a

  13. A predictive mathematical model for the calculation of the final mass of Graves' disease thyroids treated with 131I

    International Nuclear Information System (INIS)

    Traino, Antonio C; Martino, Fabio Di; Grosso, Mariano; Monzani, Fabio; Dardano, Angela; Caraccio, Nadia; Mariani, Giuliano; Lazzeri, Mauro

    2005-01-01

    Substantial reductions in thyroid volume (up to 70-80%) after radioiodine therapy of Graves' hyperthyroidism are common and have been reported in the literature. A relationship between thyroid volume reduction and outcome of 131 I therapy of Graves' disease has been reported by some authors. This important result could be used to decide individually the optimal radioiodine activity A 0 (MBq) to administer to the patient, but a predictive model relating the change in gland volume to A 0 is required. Recently, a mathematical model of thyroid mass reduction during the clearance phase (30-35 days) after 131 I administration to patients with Graves' disease has been published and used as the basis for prescribing the therapeutic thyroid absorbed dose. It is well known that the thyroid volume reduction goes on until 1 year after therapy. In this paper, a mathematical model to predict the final mass of Graves' diseased thyroids submitted to 131 I therapy is presented. This model represents a tentative explanation of what occurs macroscopically after the end of the clearance phase of radioiodine in the gland (the so-called second-order effects). It is shown that the final thyroid mass depends on its basal mass, on the radiation dose absorbed by the gland and on a constant value α typical of thyroid tissue. α has been evaluated based on a set of measurements made in 15 reference patients affected by Graves' disease and submitted to 131 I therapy. A predictive equation for the calculation of the final mass of thyroid is presented. It is based on macroscopic parameters measurable after a diagnostic 131 I capsule administration (0.37-1.85 MBq), before giving the therapy. The final mass calculated using this equation is compared to the final mass of thyroid measured 1 year after therapy administration in 22 Graves' diseased patients. The final masses calculated and measured 1 year after therapy are in fairly good agreement (R = 0.81). The possibility, for the physician, to

  14. Adhesive capsulitis of the shoulder: evaluation with MR arthrography

    International Nuclear Information System (INIS)

    Jung, Joon-Yong; Jee, Won-Hee; Chun, Ho Jong; Kim, Yang-Soo; Chung, Yang Guk; Kim, Jung-Man

    2006-01-01

    The purpose of this study was to determine the usefulness of magnetic resonance (MR) arthrography for diagnosing adhesive capsulitis. Shoulder MR images of 28 patients with (n=14) and without (n=14) adhesive capsulitis were retrospectively analyzed. MR images were assessed for capsule and synovium thickness as well as the width of the axillary recess on oblique coronal fat-suppressed T1-weighted images and T2-weighted images, respectively. On oblique sagittal fat-suppressed T1-weighted images, the width of the rotator interval and the presence of abnormal tissue in the interval were evaluated. Significant differences were found between the two groups in capsule and synovium thickness on both sides of the recess on oblique coronal T2-weighted images (P=0.000), whereas thickness on the humeral aspect showed no significant difference on oblique coronal fat-suppressed T1-weighted images (P=0.109). On oblique coronal T2-weighted images, a cut-off value of 3-mm thickness gave the highest diagnostic accuracy for adhesive capsulitis with sensitivity, specificity, and accuracy of 79% (11/14), 100% (14/14), and 89% (25/28) at the humeral side and 93% (13/14), 86% (12/14), and 89% (25/28) at the glenoid side, respectively. There were significant differences in rotator interval width, presence of abnormal tissue in the rotator interval, and axillary recess width between the two groups (P<0.05). Thickness of capsule and synovium of the axillary recess greater than 3 mm is a practical MR criterion for diagnosing adhesive capsulitis when measured on oblique coronal T2-weighted MR arthrography images without fat suppression. The presence of abnormal tissue in the rotator interval showed high sensitivity but rather low specificity. (orig.)

  15. Wireless powered capsule endoscopy for colon diagnosis and treatment

    International Nuclear Information System (INIS)

    Chen, Wenwen; Yan, Guozheng; He, Shu; Ke, Quan; Wang, Zhiwu; Liu, Hua; Jiang, Pingping

    2013-01-01

    This paper presents a wireless power transfer system integrated with an active locomotion and biopsy module in an endoscopic capsule for colon inspection. The capsule, which can move automatically, is designed for non-invasive biopsy and visual inspection of the intestine. To supply enough power for multiple functions and ensure safety for the human body, the efficiency of the current power transmission system needs to be improved. To take full advantage of the volume in the capsule body, a novel structure of receiving coils wound on a multi-core of MnZn ferrite hollow cylinder was used; with this new core, the efficiency increased to more than 7.98%. Up to 1.4 W of dc power can be delivered to the capsule as it travels along the gastrointestinal tract. Three micro motors were integrated for pumping, anchoring, locomotion and biopsy. A user interface and RF communication enables the operator to drive the capsule in an intuitive manner. To gauge the efficacy of the wireless power supply in a simulated real-world application, the biopsy and locomotion capabilities of the device were successfully tested in a slippery, soft tube and gut environment in vitro. (paper)

  16. Anomalous concentration gradient in NaI solutions inadvertently frozen in transit

    International Nuclear Information System (INIS)

    Billinghurst, M.W.; Abrams, D.N.; Coutts, A.D.

    1990-01-01

    Therapeutic doses of iodine-131 ( 131 I) are frequently dispensed volumetrically from a stock vial containing a solution of sodium iodide. During the winter months the authors have observed that initial aliquots do not always have the same radioactive concentration as that calculated for the bulk solution. In order to evaluate the cause and extent of this problem, they prepared a stock solution of low radioactive concentration sodium iodide with the same concentration of sodium thiosulfate and pH as that in the stock therapeutic iodine vial. Aliquots of this solution were transferred to plastic tubes and were stored at various temperatures. These results clearly show that when there is a risk of freezing during transportation of therapeutic solutions of sodium iodide it is essential to physically mix the liquid once thawing is complete if therapeutic doses are to be dispensed accurately on a volume basis

  17. Determination of inorganic radioiodine in 131I- Rose Bengal and 131I- bromosulphthalein

    International Nuclear Information System (INIS)

    Toledo e Souza, I.T. de; Pereira, N.P.S. de; Silva, C.P.G. da.

    1985-01-01

    A rapid miniaturized chromatographic system was developed for fast determination of the proportion of inorganic radioactive iodide from radiopharmaceuticals 131 I-Rose Bengal and 131 I-Bromosulphthalein. Using 33% W/V aqueous solution of ammonium sulphate pH 7,5 as a solvent Rf values for radiopharmaceuticals, iodide, iodate to Rf 0,0 0,5 0,9 respectively. The chromatographic quality control procedures are easy to use, rapid and can be incorporated in a routine quality control program. (Author) [pt

  18. Chord length distribution for a compound capsule

    International Nuclear Information System (INIS)

    Pitřík, Pavel

    2017-01-01

    Chord length distribution is a factor important in the calculation of ionisation chamber responses. This article describes Monte Carlo calculations of the chord length distribution for a non-convex compound capsule. A Monte Carlo code was set up for generation of random chords and calculation of their lengths based on the input number of generations and cavity dimensions. The code was written in JavaScript and can be executed in the majority of HTML viewers. The plot of occurrence of cords of different lengths has 3 peaks. It was found that the compound capsule cavity cannot be simply replaced with a spherical cavity of a triangular design. Furthermore, the compound capsule cavity is directionally dependent, which must be taken into account in calculations involving non-isotropic fields of primary particles in the beam, unless equilibrium of the secondary charged particles is attained. (orig.)

  19. Comparative assessment of hepatic Glisson's capsule and bovine pericardium in heart valve bioprostheses.

    Science.gov (United States)

    Kagramanov, I I; Kokshenev, I V; Dobrova, N B; Kastava, V T; Serov, R A; Zaets, S B

    1998-05-01

    The optimal material for heart valve bioprostheses remains disputable. This investigation was initiated to compare the properties of hepatic Glisson's capsule, clinical experience of which in cardiovascular surgery is minimal, with those of bovine pericardium. Hepatic Glisson's capsule was harvested from bull calves and used to create composite pulmonary arterial monocusp grafts and bioprostheses. Comparison of the strength and elastic properties of Glisson's capsule and bovine pericardium, as well as the hydrodynamic characteristics of valves made from these materials, was performed. Late results of operations using these materials were estimated echocardiographically. Although Glisson's capsule tissue is thinner than the bovine pericardium, its elasticity modulus is greater. However, the hydrodynamic characteristics of heart valves made from either tissue are similar. Moreover, valves made from Glisson's capsule have a lower systolic pressure gradient on the prosthesis and a higher effective orifice area. Composite pulmonary arterial xenopericardial grafts with a monocusp of Glisson's capsule were used in 30 patients during tetralogy of Fallot repair. Glisson's capsule was also used for tricuspid valve reconstruction and as a bioprosthesis in six patients with Ebstein's anomaly. At 1-2 years after surgery, the Glisson's capsule tissue remained thin and flexible, with no calcification. Although the hydrodynamic properties of hepatic Glisson's capsule and the bovine pericardium are similar, the capsule tissue is thinner and has a greater elasticity modulos. Thus, Glisson's capsule may be used for bioprosthesis construction both independently and in combination with bovine pericardium.

  20. Capsule Performance Optimization for the National Ignition Facility

    Science.gov (United States)

    Landen, Otto

    2009-11-01

    The overall goal of the capsule performance optimization campaign is to maximize the probability of ignition by experimentally correcting for likely residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. This will be accomplished using a variety of targets that will set key laser, hohlraum and capsule parameters to maximize ignition capsule implosion velocity, while minimizing fuel adiabat, core shape asymmetry and ablator-fuel mix. The targets include high Z re-emission spheres setting foot symmetry through foot cone power balance [1], liquid Deuterium-filled ``keyhole'' targets setting shock speed and timing through the laser power profile [2], symmetry capsules setting peak cone power balance and hohlraum length [3], and streaked x-ray backlit imploding capsules setting ablator thickness [4]. We will show how results from successful tuning technique demonstration shots performed at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design meet the required sensitivity and accuracy. We will also present estimates of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors, and show that these get reduced after a number of shots and iterations to meet an acceptable level of residual uncertainty. Finally, we will present results from upcoming tuning technique validation shots performed at NIF at near full-scale. Prepared by LLNL under Contract DE-AC52-07NA27344. [4pt] [1] E. Dewald, et. al. Rev. Sci. Instrum. 79 (2008) 10E903. [0pt] [2] T.R. Boehly, et. al., Phys. Plasmas 16 (2009) 056302. [0pt] [3] G. Kyrala, et. al., BAPS 53 (2008) 247. [0pt] [4] D. Hicks, et. al., BAPS 53 (2008) 2.

  1. Thermal analysis of an instrumented capsule using an ANSYS program

    International Nuclear Information System (INIS)

    Choi, Myoung Hwan; Choo, Kee Nam; Kang, Young Hwan; Cho, Man Soon; Sohn, Jae Min; Kim, Bong Goo

    2006-01-01

    An instrumented capsule has been used for an irradiation test of various nuclear materials in the research reactor, HANARO. To obtain the design data of the instrumented capsule, a thermal analysis is performed using a finite element analysis program, ANSYS. The 2-dimensional model for a cross section of the capsule including the specimens is generated, and a gamma-heating rate of the materials for the HANARO power of 24 or 30 MW is considered as an input force. The effect of the gap size and the control rod position on the temperature of the specimens or other components is discussed. From the analysis it is found that the gap between the thermal media and the external tube has a significant effect on the temperature of the specimen. In the case of the material capsule, the maximum temperature for the reactor power of 24 MW is 255degC for an irradiation test and 257degC for a FE analysis at the center stage of the capsule in the axial direction. It is expected that the analysis models using an ANSYS program will be useful in designing the instrumented capsules for an irradiation test and estimating the test results. (author)

  2. Safety Analysis Report for Primary Capsule of Ir-192 Radiation Source

    International Nuclear Information System (INIS)

    Lee, J. C.; Bang, K. S.; Choi, W. S.; Seo, K. S.; Son, K. J.; Park, W. J.

    2008-12-01

    All of the source capsules to transport a special form radioactive material should be designed and fabricated in accordance with the design criteria prescribed in IAEA standards and domestic regulations. The objective of this project is to prove the safety of a primary capsule for Ir-192 radiation source which produced in the HANARO. The safety tests of primary capsules were carried out for the impact, percussion and heat conditions. And leakage tests were carried out before and after the each tests. The capsule showed slight scratches and their deformations were not found after each tests. It also met the allowable limits of leakage rate after each test. Therefore, it has been verified that the capsule was designed and fabricated to meet all requirements for the special form radioactive materials

  3. Nuclear decay scheme studies of 30-h 131Te/sup m/, 25-min 131Te/sup g/, and 55.5-min 105Cd

    International Nuclear Information System (INIS)

    Jackson, S.V.

    1975-01-01

    High-resolution Ge(Li) detectors have been used to observe γ-ray singles and coincidence spectra of 30-h 11 / 2 - , /sup 131m/Te, 25-min 3 / 2 + , and 55.5-min 5 / 2 + 105 Cd. Sources of /sup 131m/Te and /sup 131g/Te were produced by neutron irradiation of enriched 130 Te metal, and, in the case of /sup 131m/Te, were chemically purified to remove the 131 I daughter. A total of 190 and 80 γ-rays are attributed to the decays of /sup 131m/Te and /sup 131g/Te, respectively; and 174 and 77 of these transitions have been placed in a 131 I level scheme involving 52 excited states. Absolute β group intensities were determined for the transitions to 131 I levels. Spin and parity assignments were made for all observed levels. The β feeding from the 11 / 2 - /sup 131m/Te to the 7 / 2 + 131 I ground state was determined to be (5.2 +- 3.0) percent (log ft = 10.5). The isomeric transition of 11 / 2 - /sup 131m/Te to 3 / 2 + /sup 131g/Te was determined to be (22.2 +- 1.6) percent. The 6-nsec isomer in 131 I at 1797 keV has been assigned as 15 / 2 - and interpreted as a πν 1 ν 2 three quasi-particle state. Sources of 105 Cd were produced via the 106 Cd(n,2n) reaction on enriched 106 CdO using 14 MeV neutrons. A total of 274 γ-rays are attributed to the decay of 105 Cd, and 248 of these have been placed in a 105 Ag level scheme involving 50 excited states. Absolute values for the β + /EC transition intensities to 105 Ag levels were determined. The β + /EC feeding from the 5 / 2 + 105 Cd to the 7 / 2 + 25.5-keV isomeric state in 105 Ag was determined to be (51.4 +- 4.0) percent (log ft = 5.4). The experimentally determined level structures of 131 I and 105 Cd are interpreted in terms of the shell model and core excitation considerations with emphasis placed on the core coupling model and the three-particle models. (U.S.)

  4. Approach to a system of removal of {sup 131}I of liquid discharges in a health unit of nuclear medicine using {sup 127}I as a reference standard; Planteamiento de un sistema de remocion de {sup 131}I de vertimientos liquidos en una unidad sanitaria de medicina nuclear empleando {sup 127}I como patron de referencia

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, Emeterio; Mayorga, Manuel A., E-mail: ecruzs@ecci.edu.co, E-mail: mmayorgab@ecci.edu.co [Escuela Colombiana de Carreras Industriales (ECCI), Grupo de Investigacion INDETECA (ECCI), Bogota (Colombia); Quiverio, Noelia M.; Villada, Julian D., E-mail: noelia.quiverio@estudiantes.uamerica.edu.co, E-mail: julian.villada@estudiantes.uamerica.edu.co [Fundacion Universidad de America, Grupo de Investigacion INDETECA (ECCI), Bogota (Colombia)

    2013-07-01

    The {sup 131}I prepared as potassium iodide (KI) or sodium iodide (NaI) is given to patients to treat some diseases related to the thyroid gland, in doses of 15 to 30 mCi for hyperthyroidism and 100 to 300 mCi in treatments of thyroid cancer. Up to 80% of the administered activity is discarded by the patient through the body fluids over a period of 24 h; these radioactive waste must be controlled and accordingly the different countries based on radiological impact studies establishing maximum release rates. In Colombia, the Resolution 180005 2010 establishes 1000 Bq/day (2.7027x10{sup -5} Ci /day), 10000 Bq/month (2.7027x10{sup -4} mCi/month) or 100000 Bq/year (2.7027x10{sup -3} mCi/year), this restriction requires implementing waste management methods generated by patients before discharge to the sewage networks. The method of retention of these wastes through tanks, without any treatment generates a high potential risk, therefore, this study shows three alternatives to remove the {sup 131}I in the amount of waste liquids, to generate a small solid residue in secure containers, allowing pouring fluids with radioactive traces without exceeding the limits. The sizing of the system applicable to nuclear medicine services depends on the workload of the service and combines the three methods described here by a control system, which does not require the direct intervention of staff, optimizing safety and radiation protection in the service. (author)

  5. Myofibroblast Numbers are Elevated in Human Elbow Capsules After Trauma

    OpenAIRE

    Hildebrand, Kevin A.; Zhang, Mei; van Snellenberg, Wistara; King, Graham J. W.; Hart, David A.

    2004-01-01

    Elbow contractures, a frequent problem after injury, can be treated by excision of the joint capsule. However, the underlying changes in the joint capsule are poorly understood. Based on skin healing work, we examined the hypotheses that myofibroblast numbers and expression of a myofibroblast marker α-smooth muscle actin, are elevated in patients with posttraumatic joint contractures. Anterior capsules were obtained from six patients who had operative release of posttraumatic contractures gre...

  6. Fabrication of Non-instrumented capsule for DUPIC simulated fuel irradiation test in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B.G.; Kang, Y.H.; Park, S.J.; Shin, Y.T. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-10-01

    In order to develope DUPIC nuclear fuel, the irradiation test for simulated DUPIC fuel was planed using a non-instrumented capsule in HANARO. Because DUPIC fuel is highly radioactive material the non-instrumented capsule for an irradiation test of simulated DUPIC fuel in HANARO was designed to remotely assemble and disassemble in hot cell. And then, according to the design requirements the non-instrumented DUPIC capsule was successfully manufactured. Also, the manufacturing technologies of the non-instrumented capsule for irradiating the nuclear fuel in HANARO were established, and the basic technology for the development of the instrumented capsule technology was accumulated. This report describes the manufacturing of the non-instrumented capsule for simulated DUPIC fuel. And, this report will be based to develope the instrumented capsule, which will be utilized to irradiate the nuclear fuel in HANARO. 26 refs., 4 figs. (Author)

  7. Associations Between Egg Capsule Morphology and Predation Among Populations of the Marine Gastropod, Nucella emarginata.

    Science.gov (United States)

    Rawlings, T A

    1990-12-01

    Intraspecific variation in the morphology of egg capsules is ideal for assessing the costs and benefits of encapsulation, yet little is known about the extent of such variation among populations of a single species. In the present study, I compared capsule morphology among three populations of the intertidal gastropod, Nucella emarginata. Significant differences were found both in capsule wall thickness and capsule strength. Mean capsule wall thickness varied as much as 25% among populations, with the dry weight of capsular cases differing accordingly. Capsule strength, measured as resistance to puncturing and squeezing forces, also varied among populations, but did not directly reflect differences in capsule wall thickness. Despite extensive variation in capsule morphology within this species, the number and size of eggs contained within capsules of equal volume did not differ significantly among populations. I also compared the type of capsule-eating predators that were present at each site. Shore crabs, Hemigrapsus spp., were abundant at all three sites; however, the predatory isopods Idotea wosnesenskii were only present at sites containing relatively thick-walled capsules. Although Hemigrapsus and Idotea were able to chew through both thick- and thin-walled capsules, laboratory experiments revealed that Idotea preferentially opened thin-walled capsules. These results suggest that variation in capsule morphology among populations of N. emarginata may, at least in part, reflect selection for the protection of embryos against predation.

  8. Factors affecting capsule size and production by lactic acid bacteria used as dairy starter cultures.

    Science.gov (United States)

    Hassan, A N; Frank, J F; Shalabi, S I

    2001-02-28

    The effects of sugar substrates on capsule size and production by some capsule-forming nonropy and ropy dairy starter cultures were studied. Test sugars (glucose, lactose, galactose, or sucrose) were used as a sole carbohydrate source and the presence of a capsule and its size were determined by using confocal scanning laser microscopy. Nonropy strains produced maximum capsule size when grown in milk. Strains that did not produce capsules in milk did not produce them in any other growth medium. Specific sugars required for capsule production were strain-dependent. Increasing lactose content of Elliker broth from 0.5 to 5% or adding whey protein or casein digest produced larger capsules. Whey protein concentrate stimulated production of larger capsules than did casamino acids or casitone. Some Streptococcus thermophilus strains produced capsules when grown on galactose only. Nonropy strains of Lactobacillus delbrueckii subsp. bulgaricus produced capsules on lactose, but not on glucose. A ropy strain of Lactobacillus delbrueckii subsp. bulgaricus produced a constant capsule size regardless of the growth medium. The ability of some strains of Streptococcus thermophilus to use galactose in capsule production could reduce browning of mozzarella cheese during baking by removing a source of reducing sugar. Media that do not support capsule production may improve cell harvesting.

  9. First beryllium capsule implosions on the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kline, J. L.; Yi, S. A.; Simakov, A. N.; Olson, R. E.; Wilson, D. C.; Kyrala, G. A.; Perry, T. S.; Batha, S. H.; Zylstra, A. B. [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States); Dewald, E. L.; Tommasini, R.; Ralph, J. E.; Strozzi, D. J.; MacPhee, A. G.; Callahan, D. A.; Hinkel, D. E.; Hurricane, O. A.; Milovich, J. L.; Rygg, J. R.; Khan, S. F. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); and others

    2016-05-15

    The first indirect drive implosion experiments using Beryllium (Be) capsules at the National Ignition Facility confirm the superior ablation properties and elucidate possible Be-ablator issues such as hohlraum filling by ablator material. Since the 1990s, Be has been the preferred Inertial Confinement Fusion (ICF) ablator because of its higher mass ablation rate compared to that of carbon-based ablators. This enables ICF target designs with higher implosion velocities at lower radiation temperatures and improved hydrodynamic stability through greater ablative stabilization. Recent experiments to demonstrate the viability of Be ablator target designs measured the backscattered laser energy, capsule implosion velocity, core implosion shape from self-emission, and in-flight capsule shape from backlit imaging. The laser backscatter is similar to that from comparable plastic (CH) targets under the same hohlraum conditions. Implosion velocity measurements from backlit streaked radiography show that laser energy coupling to the hohlraum wall is comparable to plastic ablators. The measured implosion shape indicates no significant reduction of laser energy from the inner laser cone beams reaching the hohlraum wall as compared with plastic and high-density carbon ablators. These results indicate that the high mass ablation rate for beryllium capsules does not significantly alter hohlraum energetics. In addition, these data, together with data for low fill-density hohlraum performance, indicate that laser power multipliers, required to reconcile simulations with experimental observations, are likely due to our limited understanding of the hohlraum rather than the capsule physics since similar multipliers are needed for both Be and CH capsules as seen in experiments.

  10. Digital instrumentation and management of dead time: first results on a NaI well-type detector setup.

    Science.gov (United States)

    Censier, B; Bobin, C; Bouchard, J; Aubineau-Lanièce, I

    2010-01-01

    The LNE-LNHB is engaged in a development program on digital instrumentation, the first step being the instrumentation of a NaI well-type detector set-up. The prototype acquisition card and its technical specifications are presented together with the first comparison with the classical NIM-based acquisition chain, for counting rates up to 100 kcps. The digital instrumentation is shown to be counting-loss free in this range. This validates the main option adopted in this project, namely the implementation of an extending dead time with live-time measurement already successfully used in the MTR2 NIM module developed at LNE-LNHB. Copyright 2010. Published by Elsevier Ltd.

  11. Potential of sago starch/carrageenan mixture as gelatin alternative for hard capsule material

    Science.gov (United States)

    Poeloengasih, Crescentiana Dewi; Pranoto, Yudi; Anggraheni, Frida Dwi; Marseno, Djagal Wiseso

    2017-03-01

    In order to replace gelatin in capsule shell production, blends of sago starch and carrageenan were developed. Films and capsules were prepared with 10% (w/v) of sago starch, 25% (w/w starch) of glycerol and various carrageenan concentration (1, 2, 3% w/w starch) in two different kappa/iota-carrageenan ratio (1:3 and 3:1). The resulted films and capsules were characterized by mechanical property, water vapor and oxygen permeability. In addition, moisture absorption and solubility of capsule in acid solution were investigated. The results reveal that addition of carrageenan makes the films stronger and less permeable. Higher kappa-carrageenan content improved tensile strength and barrier properties of the films, whereas higher iota-carrageenan content produced films with higher elongation, moisture absorption and capsule solubility in acid solution. Capsule with 2% (w/w starch) of carrageenan at kappa-/iota-ratio 3:1 had the lowest moisture absorption, whereas capsule with 3% (w/w starch) of carrageenan at kappa/iota ratio 1:3 had the highest solubility. It is illustrated that sago starch/carrageenan blends can be used as hard capsule material.

  12. Learning to Diagnose Cirrhosis with Liver Capsule Guided Ultrasound Image Classification

    Directory of Open Access Journals (Sweden)

    Xiang Liu

    2017-01-01

    Full Text Available This paper proposes a computer-aided cirrhosis diagnosis system to diagnose cirrhosis based on ultrasound images. We first propose a method to extract a liver capsule on an ultrasound image, then, based on the extracted liver capsule, we fine-tune a deep convolutional neural network (CNN model to extract features from the image patches cropped around the liver capsules. Finally, a trained support vector machine (SVM classifier is applied to classify the sample into normal or abnormal cases. Experimental results show that the proposed method can effectively extract the liver capsules and accurately classify the ultrasound images.

  13. Epidemiology and Characteristics of Escherichia coli Sequence Type 131 (ST131) from Long-Term Care Facility Residents Colonized Intestinally with Fluoroquinolone-Resistant Escherichia coli

    Science.gov (United States)

    Han, Jennifer H.; Garrigan, Charles; Johnston, Brian; Nachamkin, Irving; Clabots, Connie; Bilker, Warren B.; Santana, Evelyn; Tolomeo, Pam; Maslow, Joel; Myers, Janice; Carson, Lesley; Lautenbach, Ebbing; Johnson, James R.

    2016-01-01

    The objective of this study was to evaluate molecular and epidemiologic factors associated with Escherichia coli sequence type 131 (ST131) among long-term care facility (LTCF) residents who acquired gastrointestinal tract colonization with fluoroquinolone-resistant E. coli (FQREC). Colonizing isolates from 37 residents who newly developed FQREC colonization at three LTCFs from 2006–2008 were evaluated. Twenty-nine (78%) of 37 total FQREC colonizing isolates were ST131. Most ST131 isolates had a distinctive combination of gyrA and parC replacement mutations. The ST131 and non-ST131 isolates differed significantly for the prevalence of many individual virulence factors but not for the proportion that qualified molecularly as extraintestinal pathogenic E. coli (ExPEC) or aggregate virulence factor scores. E. coli ST131 was highly prevalent among LTCF residents with FQREC colonization. Future studies should determine the risk factors for infection among ST131-colonized residents, and assess the potential for increased transmissibility of ST131 in the long-term care setting. PMID:27939288

  14. Improvement and utilization of irradiation capsule technology in HANARO

    International Nuclear Information System (INIS)

    Choo, Kee-Nam; Cho, Man-Soon; Kim, Bong-Goo; Lee, Cheol-Yong; Yang, Sung-Woo; Shin, Yoon-Taek; Park, Seng-Jae; Jung, Hoan-Sung

    2012-01-01

    Several improvements of irradiation capsule technology regarding irradiation test parameters, such as temperature and neutron flux/fluence, and regarding instrumentation have progressed at HANARO since the last KAERI-JAERI joint seminar held in 2008. The standard HANARO capsule technology that was developed for use in a commercial power plant temperature of about 300degC was improved to apply to a temperature range of 100-1000degC for the irradiation test of materials of new research reactors and future nuclear systems. Low-flux and long-term irradiation technologies have been developed at HANARO. As a beginning step of the localization of capsule instrumentation technology, the irradiation performance of a domestically produced thermocouple and LVDT will be examined at HANARO. The accuracy of an evaluation of neutron fluence and precise welding technology are also being examined at HANARO. Based on these accumulated capsule technologies, a HANARO irradiation capsule system is being actively utilized for the national R and D programme on commercial nuclear reactors and nuclear fuel cycle technology in Korea. HANARO has recently started the irradiation support of R and D relevant to future nuclear systems including SMART, VHTR, and SFR, and HANARO is preparing new support relevant to new research and Fusion reactors. (author)

  15. Malign pheochromocytoma: importance of the scintigraphic follow-up with metaiodobenzulguanidine 131I (MIBG-131I)

    International Nuclear Information System (INIS)

    Kato, M.; Velhote, V.V.; Souto, F.J.P.; Long, Y.J.; Costa, P.L.A.

    1989-01-01

    The authors report a case of pheochromocytoma investigated with metaiodobenzylguanidine labeled with 131 I (MIBG- 131 I). The methodology identify primitive lesion, its recurrence and metastasis. The authors mention the advantage of the technique due to the high specificity, sensitivity and because it is harmless, offering optimal information about the morphology and functional nature, concerning diagnosis and follow-up of the disease. (author) [pt

  16. Molecular orientation via a dynamically induced pulse-train: Wave packet dynamics of NaI in a static electric field

    DEFF Research Database (Denmark)

    Marquetand, P.; Materny, A.; Henriksen, Niels Engholm

    2004-01-01

    We regard the rovibrational wave packet dynamics of NaI in a static electric field after femtosecond excitation to its first electronically excited state. The following quasibound nuclear wave packet motion is accompanied by a bonding situation changing from covalent to ionic. At times when...... the charge separation is present, i.e., when the bond-length is large, a strong dipole moment exists and rotational excitation takes place. Upon bond contraction, the then covalently bound molecule does not experience the external field. This scenario repeats itself periodically. Thus, the vibrational...

  17. Thermohydraulic design of saturated temperature capsule for IASCC irradiation test

    International Nuclear Information System (INIS)

    Ide, Hiroshi; Matsui, Yoshinori; Itabashi, Yukio

    2002-10-01

    An advanced water chemistry controlled irradiation research device is being developed in JAERI, to perform irradiation tests for irradiation assisted stress corrosion cracking (IASCC) research concerned with aging of LWR. This device enables the irradiation tests under the water chemistry condition and the temperature, which simulate the conditions for BWR core internals. The advanced water chemistry controlled irradiation research device is composed of saturated temperature capsule inserted into the JMTR core and the water chemistry control unit installed in the reactor building. Regarding the saturated temperature capsule, the Thermohydraulic design of capsule structure was done, aimed at controlling the specimen's temperature, feeding water velocity on specimen's surface to the environment of BWR nearer. As the result of adopting the new capsule structure based on the design study, it was found out that feeding water velocity at the surface of specimen's is increased to about 10 times as much as before, and nuclear heat generated in the capsule components can be removed safely even in the abnormal event such as the case of loss of feeding water. (author)

  18. Thermohydraulic design of saturated temperature capsule for IASCC irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Ide, Hiroshi; Matsui, Yoshinori; Itabashi, Yukio [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2002-10-01

    An advanced water chemistry controlled irradiation research device is being developed in JAERI, to perform irradiation tests for irradiation assisted stress corrosion cracking (IASCC) research concerned with aging of LWR. This device enables the irradiation tests under the water chemistry condition and the temperature, which simulate the conditions for BWR core internals. The advanced water chemistry controlled irradiation research device is composed of saturated temperature capsule inserted into the JMTR core and the water chemistry control unit installed in the reactor building. Regarding the saturated temperature capsule, the Thermohydraulic design of capsule structure was done, aimed at controlling the specimen's temperature, feeding water velocity on specimen's surface to the environment of BWR nearer. As the result of adopting the new capsule structure based on the design study, it was found out that feeding water velocity at the surface of specimen's is increased to about 10 times as much as before, and nuclear heat generated in the capsule components can be removed safely even in the abnormal event such as the case of loss of feeding water. (author)

  19. 46 CFR 131.960 - Use of auto-pilot.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Use of auto-pilot. 131.960 Section 131.960 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Miscellaneous § 131.960 Use of auto-pilot. When the automatic pilot is used in areas of high traffic density...

  20. 49 CFR 28.131 - Illegal use of drugs.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Illegal use of drugs. 28.131 Section 28.131 Transportation Office of the Secretary of Transportation ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY THE DEPARTMENT OF TRANSPORTATION § 28.131 Illegal use of...

  1. Treatment's results of hyperthyroid patients with Iodine-131

    International Nuclear Information System (INIS)

    Bastan-Hagh, M.H.; Larijani, B.; Rahim-Tabrizi, P.; Khalili-Fard, A.R.; Baradar-Jalili, R.; Saghari, M.

    2004-01-01

    Introduction: radioiodine ( 131 I) is an effective and inexpensive alternative to surgery in the treatment of thyroid hyper function. The debate today concerns the maximum and minimum ablative doses, and factors leading to hypothyroidism. Patients and method: 1035 hyperthyroid patients treated with weight-adjusted ablative doses of 131 I were retrospectively assessed for treatment outcome or correlated with sex, age, underlying pathology, and administrated dose of 131 I . Results: Thyroid hyper function was more common in women. The greatest proportions of patients were in the 31-40 years age group and the smallest proportion over -70. The commonest underlying pathology was Grave's disease. Men had a lower response rate to 131 I therapy, with 2.4-fold greater probability of persistent hyperthyroidism (P 131 I hypothyroidism decreased with increasing age (P 131 I therapy was seen in patients with toxic adenoma, (P=0.0001). The incidence of hypothyroidism did not show a positive correction with increased administered dose of 131 I (P 131 I was effective in reducing thyroid nodule size. There were 18 cases of temporary hyperthyroidism, all of which recovered to euthyroid status within 12 months. Conclusion: one dose of radioiodine was effective in treatment of hyperthyroid patients in 91.2 % of cases. Age, sex and underlying pathology were determining factors. In most cases the average time to hypothyroidism was reasonably short, obviating the need for long time follow up in these patients

  2. 131I therapy of Graves' disease using lithium

    International Nuclear Information System (INIS)

    Sato, Kenshi

    1983-01-01

    Lithium is known to cause goiter and hypothyroidism. In the mechanism of goitrogenesis, there is general agreement that lithium inhibits the release of the thyroid hormones from the thyroid gland without significantly impairing other thyroid functions. The present study was undertaken, therefore, to investigate the usefulness of lithium in the radioiodine treatment of Graves' disease. Nine patients with Graves' disease who were all, except one, previously treated with antithyroid drugs were studied. 600 mg of lithium carbonate were administered daily to investigate the effects on thyroidal 131 I uptake, disappearance rate of 131 I from the prelabeled thyroid and the serum concentrations of thyroid hormones. Lithium showed no significant effect on the thyroidal 131 I uptake when the 24 hour thyroidal 131 I uptakes were determined both before and during lithium treatment in the five cases. On the other hand, lithium clearly prolonged the mean value of effective half-lives of 131 I to approximately 8 days vs. 5.1 days before lithium treatment (p 4 and T 3 levels significantly decreased during lithium treatment, from 21.3 to 12.4μg/dl (n=9, p 131 I for the Graves' disease can be reduced by using lithium, the radiation exposure to the total body is decreased. Moreover, it is possible to perform the 131 I therapy while improving the thyrotoxicosis with lithium. Finally, it is concluded that lithium is a very useful drug to be combined with the 131 I therapy of Graves' disease. (author)

  3. Adhesive capsulitis: contrast-enhansed shoulder MRI findings

    International Nuclear Information System (INIS)

    Gokalp, Gokhan; Yildirim, Nalan; Yazici, Zeynep; Algin, Oktay

    2011-01-01

    Full text: Evaluation of contrast-enhanced magnetic resonance imaging (CE-MRI) findings in cases clinically diagnosed as adhesive capsulitis (AC). CE-MRI images of 12 cases diagnosed as AC (13 shoulder joints) and nine control cases were retrospectively evaluated. AC diagnosis was establlished based on the history and clinical symptoms. MR signal intensity changes in the axillary pouch, rotator interval, biceps anchor and anterior posterior capsules were analysed with regard to the presence of abnormal soft tissue and contrast enhancement. Capsular and synovial thickening were measured in the axillary recess and rotator interval on coronal oblique CE T1-weighted images. Patient and control groups were compared by Fisher's exact and McNemar tests in terms of signal intensity changes and contrast enhancement in the described areas. Results: Comparison of the group with AC and the control group regarding intensity changes showed a statistically significant difference in the axillary pouch (P 0.05). Comparison of AC and control groups in terms of contrast enhancement revealed statistically significant differences in the axillary pouch, rotator interval, biceps anchor and anterior-posterior capsules (P < 0.001). A significant difference was determined between the AC and control groups with regard to thickening in axillary pouch and rotator interval (P < 0.001). CE studies are useful for diagnosis of AC as it demonstrates thickening of specific soft-tissue areas like joint capsule and synovium.

  4. Criteria for cesium capsules to be shipped as special form radioactive material

    International Nuclear Information System (INIS)

    Lundeen, J.E.

    1994-01-01

    The purpose of this report is to compile all the documentation which defines the criteria for Waste Encapsulation and Storage Facility (WESF) cesium capsules at the IOTECH facility and Applied Radiant Energy Corporation (ARECO) to be shipped as special form radioactive material in the Beneficial Uses Shipping System (BUSS) Cask. The capsules were originally approved as special form in 1975, but in 1988 the integrity of the capsules came into question. WHC developed the Pre-shipment Acceptance Test Criteria for capsules to meet in order to be shipped as special form material. The Department of Energy approved the criteria and directed WHC to ship the capsules at IOTECH and ARECO meeting this criteria to WHC as special form material

  5. 131I radiocapsules as a means of administering iodide to patients for diagnoses and/or therapy

    International Nuclear Information System (INIS)

    Pillay, M.; Li Jun; Berghout, A.; Cox, P.H.

    1994-01-01

    The use of radioiodide solution either for intravenous (sterile), or for oral use carries a risk of spillage and contamination (3). In addition, the amount of activity administered is seldom complete in terms of the absolute amount dispensed so that there always is 'left-over' activity in the syringe or beaker. This is particularly important when determining the 24 hour uptake of radioiodide in the thyroid. The use of encapsulated forms of iodide-131 excludes errors due to 'left-over' activity, and is certainly preferred from the radiation hygiene point of view. Radiocapsules are easy to administer and may even be used in uncooperative patients as described by Lowry et al (2). The widespread use of radiocapsules has been restricted because of concern about the speed of dissolution of the radiocapsules in the stomach (4). In this study we investigated the speed of the capsule disintegration in in-vitro, as well as in patients. (orig.) [de

  6. Clinical effect of Resina Draconis capsules on primary dysmenorrhoea

    African Journals Online (AJOL)

    Clinical effect of Resina Draconis capsules on primary dysmenorrhoea. Li Sun, Jia Wang. Abstract. Purpose: To examine the effectiveness of Resina Draconis capsules in the treatment of primary dysmenorrhoea. Methods: In total, 324 patients with primary dysmenorrhoea were randomly allocated to three groups based on ...

  7. Design Improvements of a Fuel Capsule for Re-irradiation Tests

    International Nuclear Information System (INIS)

    Kang, Young-Hwan; Choi, Myung-Hwan; Kim, Jong Kiun; Youm, Ki Un; Yoon, Ki Byeong; Kim, Bong Goo

    2006-01-01

    The development of an advanced reactor system such as the next generation nuclear plant and other generation IV systems require new fuels, claddings, and structural materials. To characterize the performance of these new materials, it is necessary for us to have leading-edge technology to satisfy the specific test requirements of the recent R and D activities such as the high-fluence- and high burnup- related tests. Thus, new capsule assembling technology and re-instrumentation technology has been developed to meet the demands for the high burnup test at HANARO since 2003. In 2003, a mockup of the capsule assembly machine was designed and fabricated. The performance test which started in 2004 was undertaken to determine and present the main performance characteristics of the capsule assembly machine (CAM) including the special tools. In 2005, a series of analyses using a finite element analysis program, ANSYS and full scale tests in air were performed to improve the design of the capsule's components for an effective utilization of the CAM. The handling tools were fully qualified through the performance tests in 2006. KAERI is now reviewing the water flow area in the top region of a fuel capsule main body for re-irradiation tests and optimizing the design of the central region area of a capsule to be joined with special bolts

  8. 46 CFR 131.575 - Yearly inspections and repair.

    Science.gov (United States)

    2010-10-01

    ... repaired as needed at least once a year. This procedure includes emptying and cleaning each fuel tank and... 46 Shipping 4 2010-10-01 2010-10-01 false Yearly inspections and repair. 131.575 Section 131.575..., Drills, and Inspections § 131.575 Yearly inspections and repair. (a) Each lifeboat, rescue boat, rigid...

  9. Adhesive capsulitis: review of imaging and treatment

    International Nuclear Information System (INIS)

    Harris, Guy; Bou-Haider, Pascal; Harris, Craig

    2013-01-01

    Adhesive capsulitis is one of the most common conditions affecting the shoulder; however, early clinical diagnosis can be challenging. Treatment is most effective when commenced prior to the onset of capsular thickening and contracture; consequently, the role of imaging is increasing. The aim of this review is to demonstrate the typical imaging appearances of adhesive capsulitis and to examine some of the evidence regarding each of these imaging modalities. An evaluation of the various management options available to the clinician is also presented.

  10. Orion Versus Poseidon: Understanding How Nasa's Crewed Capsule Survives Nature's Fury

    Science.gov (United States)

    Barbre, Robert E., Jr.

    2016-01-01

    This presentation summarizes the Marshall Space Flight Center Natural Environments Terrestrial and Planetary Environments (TPE) Team support to the NASA Orion space vehicle. The Orion vehicle, part of the Multi-Purpose Crew Vehicle Program, is designed to carry astronauts beyond low-Earth orbit and is currently undergoing a series of tests including Exploration Flight Test (EFT)-1. This design must address the natural environment to which the capsule and launch vehicle are exposed during all mission phases. In addition, the design must, to the best extent possible, implement the same process and data to be utilized on launch day. The TPE utilizes meteorological data to assess the sensitivities of the vehicle due to the terrestrial environment. The presentation describes examples of TPE support for vehicle design and several tests, as well as support for EFT-1 and planning for upcoming Exploration Missions while emphasizing the importance of accounting for the natural environment's impact to the vehicle early in the vehicle's program.

  11. Validity, Reliability, and Inertia of Four Different Temperature Capsule Systems.

    Science.gov (United States)

    Bongers, Coen C W G; Daanen, Hein A M; Bogerd, Cornelis P; Hopman, Maria T E; Eijsvogels, Thijs M H

    2018-01-01

    Telemetric temperature capsule systems are wireless, relatively noninvasive, and easily applicable in field conditions and have therefore great advantages for monitoring core body temperature. However, the accuracy and responsiveness of available capsule systems have not been compared previously. Therefore, the aim of this study was to examine the validity, reliability, and inertia characteristics of four ingestible temperature capsule systems (i.e., CorTemp, e-Celsius, myTemp, and VitalSense). Ten temperature capsules were examined for each system in a temperature-controlled water bath during three trials. The water bath temperature gradually increased from 33°C to 44°C in trials 1 and 2 to assess the validity and reliability, and from 36°C to 42°C in trial 3 to assess the inertia characteristics of the temperature capsules. A systematic difference between capsule and water bath temperature was found for CorTemp (0.077°C ± 0.040°C), e-Celsius (-0.081°C ± 0.055°C), myTemp (-0.003°C ± 0.006°C), and VitalSense (-0.017°C ± 0.023°C; P 0.05). Comparable inertia characteristics were found for CorTemp (25 ± 4 s), e-Celsius (21 ± 13 s), and myTemp (19 ± 2 s), whereas the VitalSense system responded more slowly (39 ± 6 s) to changes in water bath temperature (P inertia were observed between capsule systems, an excellent validity, test-retest reliability, and inertia was found for each system between 36°C and 44°C after removal of outliers.

  12. Strontium and cesium radionuclide leak detection alternatives in a capsule storage pool

    International Nuclear Information System (INIS)

    Larson, D.E.; Crawford, T.W.; Joyce, S.M.

    1981-08-01

    A study was performed to assess radionuclide leak-detection systems for use in locating a capsule leaking strontium-90 or cesium-137 into a water-filled pool. Each storage pool contains about 35,000 L of water and up to 715 capsules, each of which contains up to 150 kCi strontium-90 or 80 kCi cesium-137. Potential systems assessed included instrumental chemical analyses, radionuclide detection, visual examination, and other nondestructive nuclear-fuel examination techniques. Factors considered in the assessment include: cost, simplicity of maintenance and operation, technology availability, reliability, remote operation, sensitivity, and ability to locate an individual leaking capsule in its storage location. The study concluded that an adaption of the spent nuclear-fuel examination technique of wet sipping be considered for adaption. In the suggested approoch, samples would be taken continuously from pool water adjacent to the capsule(s) being examined for remote radiation detection. In-place capsule isolation and subsequent water sampling would confirm that a capsule was leaking radionuclides. Additional studies are needed before implementing this option. Two other techniques that show promise are ultrasonic testing and eddy-current testing

  13. Effective Half-life of I-131 in Patients with Differentiated Thyroid Cancer Treated by Radioactive I-131

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seok Gun [Dankook University, Cheonan (Korea, Republic of)

    2008-12-15

    Effective half life of I-131 (T{sub eff}) in patients with differentiated thyroid cancer treated by I-131 is must-know value for dose calculation and determination of release time from isolation room. There has been no report about T{sub eff} in Koreans. Thus, author tried to measure dose rate without radiation exposure to faculty members and calculated T{sub eff}. Probe of radiation survey meter was fixed at the wall of isolation room, and body of survey meter was placed outside the room. With this simple arrangement, author could measure radiation frequently without radiation exposure to faculty members in 68 patient (F=55, M=13, age=47{+-}13.7) treated by I-131 (3.7{approx}7.4 GBq) for differentiated thyroid cancer from Jan 2006 to Dec 2006. From this data, T{sub eff}, 48 hr retention rate, and the time necessary to whole body retention of I-131 become less than 1.1 GBq were calculated. Serum creatinine levels were measured before and after thyroid hormone withdrawal. T{sub eff} was 15.4{+-}4.3 hr (9.4{approx}32.5 hr). There was a loose correlation between T{sub eff} and serum creatinine concentration (r=0.45). 48hr retention was 4.9{+-}4.2% (1{approx}23%). Time necessary to whole body retention of I-131 become less than 1.1 GBq was calculated as 47.1{+-}13.2 hr for 9.25 GBq, 42.1{+-}11.9 hr for 7.4 GBq, 35.7{+-}10.0 hr for 5.55 GBq, and 26.7{+-}7.5 hr for 3.7 GBq dose of I-131. Author successfully measured radiation dose rates in isolated patients treated by high dose of I-131 without radiation exposure to the faculty members with simple arrangement of survey meter probe. Using those data, T{sub eff} and some other indices were calculated.

  14. State diagram for adhesion dynamics of deformable capsules under shear flow.

    Science.gov (United States)

    Luo, Zheng Yuan; Bai, Bo Feng

    2016-08-17

    Due to the significance of understanding the underlying mechanisms of cell adhesion in biological processes and cell capture in biomedical applications, we numerically investigate the adhesion dynamics of deformable capsules under shear flow by using a three-dimensional computational fluid dynamic model. This model is based on the coupling of the front tracking-finite element method for elastic mechanics of the capsule membrane and the adhesion kinetics simulation for adhesive interactions between capsules and functionalized surfaces. Using this model, three distinct adhesion dynamic states are predicted, such as detachment, rolling and firm-adhesion. Specifically, the effects of capsule deformability quantified by the capillary number on the transitions of these three dynamic states are investigated by developing an adhesion dynamic state diagram for the first time. At low capillary numbers (e.g. Ca state no longer appears, since capsules exhibit large deviation from the spherical shape.

  15. Capsule Development and Utilization for Material Irradiation Tests

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Kang, Y H; Cho, M S [and others

    2007-06-15

    The essential technology for an irradiation test of materials and nuclear fuel has been successively developed and utilized to meet the user's requirements in Phase I(July 21, 1997 to March 31, 2000). It enables irradiation tests to be performed for a non-fissile material under a temperature control(300{+-}10 .deg. C) in a He gas environment, and most of the irradiation tests for the internal and external users are able to be conducted effectively. The basic technology was established to irradiate a nuclear fuel, and a creep capsule was also developed to measure the creep property of a material during an irradiation test in HANARO in Phase II(April 1, 2000 to March 31, 2003). The development of a specific purpose capsule, essential technology for a re-irradiation of a nuclear fuel, advanced technology for an irradiation of materials and a nuclear fuel were performed in Phase III(April 1, 2003 to February 28, 2007). Therefore, the technology for an irradiation test was established to support the irradiation of materials and a nuclear fuel which is required for the National Nuclear R and D Programs. In addition, an improvement of the existing capsule design and fabrication technology, and the development of an instrumented capsule for a nuclear fuel and a specific purpose will be able to satisfy the user's requirements. In order to support the irradiation test of materials and a nuclear fuel for developing the next generation nuclear system, it is also necessary to continuously improve the design and fabrication technology of the existing capsule and the irradiation technology.

  16. Merkel cell carcinoma and iodine-131 metaiodobenzylguanidine scan

    International Nuclear Information System (INIS)

    Castagnoli, A.; Biti, G.; De Cristofaro, M.T.R.; Papi, M.G.; Ferri, P.; Magrini, S.M.; Bianchi, S.

    1992-01-01

    Two cases of Merkel cell carcinoma, a neuroendocrine neoplasia of the skin, investigated with iodine, 131 metaiodobenzylguanidine ( 131 I-mIBG) scintigraphy, are reported. Uptake in the tumor was evident only in 1 case. The possible diagnostic and therapeutic role of 131 I-mIBG in patients with this rare neoplasm is discussed. (orig.)

  17. Breast cancer following 131I therapy for hyperthyroidism

    International Nuclear Information System (INIS)

    Hoffman, D.A.; McConahey, W.M.

    1983-01-01

    A retrospective cohort study of women treated for hyperthyroidism at the Mayo Clinic between 1946 and 1964 was conducted to determine if 1,005 women treated with ( 131 I) were at increased risk of breast cancer compared with 2,141 women traced, and a response (death certificate or questionnaire) was received for 99% of the traced women. The average duration of follow-up was 15 years for the 131 I-treated women and 21 years for women treated surgically. No increased risk of breast cancer was observed in the 131 I-treated women (adjusted relative risk . 0.8). No patterns were found of increased breast cancer risk by age at first treatment, by time since treatment, or by total exposure to 131 I. Failure to detect an increased risk of breast cancer in the 131 I-treated women was attributed to the moderately low doses from 131 I therapy and the relatively small number of exposed women. The study also failed to find any increased risk of breast cancer associated with hyperthyroidism

  18. Anterior Lens Capsule and Iris Thicknesses in Pseudoexfoliation Syndrome.

    Science.gov (United States)

    Batur, Muhammed; Seven, Erbil; Tekin, Serek; Yasar, Tekin

    2017-11-01

    The aim of this study was to evaluate anatomic properties of the lens capsule and iris by anterior segment optical coherence tomography (AS-OCT) in patients with pseudoexfoliation (PEX). This prospective study included 62 eyes of 62 patients with PEX syndrome and 43 eyes of 43 age- and gender-matched controls. All subjects underwent full ophthalmologic examinations including AS-OCT. Pupillary diameter, midperipheral stromal iris thickness, central and temporal lens capsule thicknesses, and peripheral pseudoexfoliation material thickness on the anterior lens capsule surface were measured and recorded. Mean age was 66.8 ± 9.3 years in the PEX group and 65.5 ± 8.9 years in the control group (p = 0.44). The PEX group consisted of 62 patients: 38 men (61.3%) and 24 women (38.7%); the control group included 43 subjects: 25 men (58.1%) and 18 women (41.9%). Pupillary diameter after pharmacologic mydriasis was 21% smaller in the PEX group than controls. Mean midperipheral iris thickness was 36 ± 7.2 μm (7.8%) thinner in the PEX group than that of control group (p = 0.047). The central anterior capsule was a mean of 3.40 ± 0.51 μm (18%) thicker in the PEX group compared to the control group (p = 0.0001). The temporal anterior lens capsule was a mean of 0.17 ± 0.15 μm thicker in the PEX group compared to the control group (p = 0.81). With high-resolution OCT imaging, it has become possible to evaluate the anterior lens capsule without histologic examination and demonstrate that it is thicker than normal in PEX patients.

  19. Hypothyroidism following 131I therapy for hyperthyroidism

    International Nuclear Information System (INIS)

    Kubo, Atsushi; Kondo, Makoto; Kinoshita, Fumio; Maekawa, Akira; Okamoto, Jiro.

    1977-01-01

    Of 890 patients who received 131 I therapy for hyperthyroidism, the results of therapy were examined on 584 who could be followed up. Of these 502 (86%), were sured including 3 patients who had been completely healed after recurrence, 9 patients are still under medical treatment, and 10 died. The incidence of hypothyroidism following 131 I therapy was 1.6% after 1 year, 2.3% after 2 years, 4.7% after 5 years, 15.0% after 10-12 years, 22.1% after 13-15 years and 27.5% after 16-20 years. The incidence increased constantly with the passage of time. Factors influencing the response to treatment have been investigated. As a consequence, the number of rads delivered to the thyroid gland, the gland size, and previous surgery correlated with the incidence of hypothyroidism. The number of doses of 131 I, uptake and half-life of 131 I in the thyroid, previous antithyroid medication, time between the onset of hyperthyroid symptoms and 131 I therapy, and the age or sex of the patients appeared unrelated. The times taken to become euthyroid following a single dose of 131 I were 5.6 months with 2000-4000 rads, 4.4 months with 4001-7000 rads, 4.2 months with 7001-10000 rads and 3.5 months with more than 10001 rads. The time was prolonged with decrease of rads delivered to the thyroid gland. It was found that the patients who passed through a transient hypothyroid phase in the period of three to four months after administration of 131 I had a high incidence of late permanent hypothyroidism. (Evans, J.)

  20. 46 CFR 131.935 - Prevention of oil pollution.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Prevention of oil pollution. 131.935 Section 131.935... Miscellaneous § 131.935 Prevention of oil pollution. Each vessel must be operated in compliance with— (a) Section 311 of the Federal Water Pollution Control Act, as amended (33 U.S.C. 1321); and (b) 33 CFR parts...

  1. Characterisation of two AGATA asymmetric high purity germanium capsules

    International Nuclear Information System (INIS)

    Colosimo, S.J.; Moon, S.; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Harkness-Brennan, L.; Judson, D.S.; Lazarus, I.H.; Nolan, P.J.; Simpson, J.; Unsworth, C.

    2015-01-01

    The AGATA spectrometer is an array of highly segmented high purity germanium detectors. The spectrometer uses pulse shape analysis in order to track Compton scattered γ-rays to increase the efficiency of nuclear spectroscopy studies. The characterisation of two high purity germanium detector capsules for AGATA of the same A-type has been performed at the University of Liverpool. This work will examine the uniformity of performance of the two capsules, including a comparison of the resolution and efficiency as well as a study of charge collection. The performance of the capsules shows good agreement, which is essential for the efficient operation of the γ-ray tracking array

  2. Characterisation of two AGATA asymmetric high purity germanium capsules

    Energy Technology Data Exchange (ETDEWEB)

    Colosimo, S.J., E-mail: sjc@ns.ph.liv.ac.uk [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Moon, S.; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Harkness-Brennan, L.; Judson, D.S. [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Lazarus, I.H. [STFC Daresbury, Daresbury, Warrington WA4 4AD (United Kingdom); Nolan, P.J. [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Simpson, J. [STFC Daresbury, Daresbury, Warrington WA4 4AD (United Kingdom); Unsworth, C. [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom)

    2015-02-11

    The AGATA spectrometer is an array of highly segmented high purity germanium detectors. The spectrometer uses pulse shape analysis in order to track Compton scattered γ-rays to increase the efficiency of nuclear spectroscopy studies. The characterisation of two high purity germanium detector capsules for AGATA of the same A-type has been performed at the University of Liverpool. This work will examine the uniformity of performance of the two capsules, including a comparison of the resolution and efficiency as well as a study of charge collection. The performance of the capsules shows good agreement, which is essential for the efficient operation of the γ-ray tracking array.

  3. Analysis of mechanical property data obtained from nuclear pressure vessel surveillance capsules

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1977-01-01

    A typical pressure vessel surveillance capsule examination program provides mechanical property data from tensile, Charpy V-notch impact, and, in some cases, fracture mechanics specimens. This data must be analyzed in conjunction with the unirradiated baseline mechanical property data to determine the effect of irradiation on the mechanical properties. In the case of Charpy impact specimens, for example, irradiation typically causes an increase in the transition temperature, and a decrease in the upper shelf energy level. The results of the Charpy impact and other mechanical specimen tests must be evaluated to determine if property changes are occurring in the manner expected when the reactor was put into service. The large amount of data obtained from surveillance capsule examinations in recent years enables one to make fairly good predictions. After the changes in the mechanical properties of specimens from a particular surveillance capsule have been experimentally determined and evaluated, they must be related to the reactor pressure vessel. This requires a knowledge of the neutron fluence of the surveillance capsule, and the ratio of the surveillance capsule fluence to the pressure vessel wall fluence. This ratio is frequently specified by the reactor manufacturer, or can be calculated from a knowledge of the geometry and materials of the reactor components inside the pressure vessel. A knowledge of the exact neutron fluence of the capsule specimens and the capsule to vessel wall neutron fluence ratio is of great importance, since inaccuracies in these numbers cause just as serious a problem as inaccuracies in the mechanical property determinations. A further area causing analysis difficulties is problems encountered in recent capsule programs relating to capsule design, construction, operation, and dismantling. (author)

  4. Capsule Performance Optimization in the National Ignition Campaign

    Energy Technology Data Exchange (ETDEWEB)

    Landen, O L; MacGowan, B J; Haan, S W; Edwards, J

    2009-10-13

    A capsule performance optimization campaign will be conducted at the National Ignition Facility to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  5. Capsule performance optimization in the national ignition campaign

    International Nuclear Information System (INIS)

    Landen, O L; MacGowan, B J; Haan, S W; Edwards, J

    2010-01-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [1] to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  6. Capsule performance optimization in the national ignition campaign

    Science.gov (United States)

    Landen, O. L.; MacGowan, B. J.; Haan, S. W.; Edwards, J.

    2010-08-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [1] to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  7. Integrity Assessment of HANARO Irradiation Capsule for Long-Term Irradiation Testing

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Kee Nam; Cho, Man Soon; Yang, Sung Woo; Shin, Yoon Taek; Park, Seng Jae; Yang, Tae Ho; Jun, Byung Hyuk; Kim, Myong Seop [KAERI, Daejeon (Korea, Republic of); Hong, Sang Hyun [Chungnam University, Daejeon (Korea, Republic of)

    2016-05-15

    The capsule technology was basically developed for irradiation testing under a commercial reactor operation environment. Most irradiation testing using capsules has been performed at around 300 .deg. C within four reactor operation cycles (about 100 days equivalent to 1.5 dpa (displacement for atom)) at HANARO. Based on the accumulated experience as well as the sophisticated requirements of users, HANARO has recently been required to support national R and D projects requiring much higher neutron fluence. To scope the user requirements for higher neutron irradiation fluence, several efforts using an instrumented capsule have been applied at HANARO. In this paper, the applied stresses on the capsule are estimated because the capsule was suspected to be susceptible to fatigue failure during irradiation testing. In addition, the on-going design improvements of the irradiation capsule for higher neutron irradiation fluence at HANARO are described. The applied stresses on the rod tip were analyzed using the ANSYS program. The applied stresses on the rod tip can be classified into stresses by the designed bottom spring, by the upward flowing coolant, by the capsule vibration, and by the welding residual stress. The maximal stresses due to the first three factors were estimated as 5.4 MPa, 132.9 MPa, and 161 MPa, respectively. These stresses do not exceed the known fatigue strength of stainless steels (∼300 MPa). Residual stress by welding is another possible stress and it is known to occur at up to about 300 MPa.

  8. WESF cesium capsule behavior at high temperature or during thermal cycling

    International Nuclear Information System (INIS)

    Tingey, G.L.; Gray, W.J.; Shippell, R.J.; Katayama, Y.B.

    1985-06-01

    Double-walled stainless steel (SS) capsules prepared for storage of radioactive 137 Cs from defense waste are now being considered for use as sources for commercial irradiation. Cesium was recovered at B-plant from the high-level radioactive waste generated during processing of defense nuclear fuel. It was then purified, converted to the chloride form, and encapsulated at the Hanford Waste Encapsulation and Storage Facility (WESF). The molten cesium chloride salt was encapsulated by pouring it into the inner of two concentric SS cylinders. Each cylinder was fitted with a SS end cap that was welded in place by inert gas-tungsten arc welding. The capsule configuration and dimensions are shown in Figure 1. In a recent review of the safety of these capsules, Tingey, Wheelwright, and Lytle (1984) indicated that experimental studies were continuing to produce long-term corrosion data, to reaffirm capsule integrity during a 90-min fire where capsule temperatures reached 800 0 C, to monitor mechanical properties as a function of time, and to assess the effects of thermal cycling due to periodic transfer of the capsules from a water storage pool to the air environment of an irradiator facility. This report covers results from tests that simulated the effects of the 90-min fire and from thermal cycling actual WESF cesium capsules for 3845 cycles over a period of six months. 11 refs., 39 figs., 9 tabs

  9. Radioactive Iodine (I-131) Therapy for Hyperthyroidism

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Radioactive Iodine (I-131) Therapy Radioiodine therapy is a nuclear ... thyroid cancer. When a small dose of radioactive iodine I-131 (an isotope of iodine that emits ...

  10. A Comparative Study of 131I-Hippuran Renogram, 131I-Hippuran Urinary Excretion Test and Intravenous Pyelogram in Obstructive Uropathy due to Cancerous Invasion

    International Nuclear Information System (INIS)

    Park, Kee Bok; Rhee, Chong Heon; Hong, Chang Gi; Park, Soo Seong; Koh, Chang Soon

    1968-01-01

    A comparative study of 131 I-hippuran renogram, 131 I-hippuran excretion test and intravenous pyelogram were performed in 61 cases of gynecological cancer. The following were the results: 1) Among 40 cases of cervix cancer showing normal excretory urography 7 cases (17.5%) were found to have unilateral or bilateral delayed excretory pattern on 131 I-hippuran renogram and on the contrary only 2 cases (5.7%) showed a mild caliectatic change on excretory urography among 35 cases of gynecological cancer showing normal pattern of 131 I-hippuran renogram. 2) In the group showing unilateral of bilateral delayed excretory pattern of 131 I-hippuran renogram there was a reduction of 131 I-hippuran excretion in the first 20 minutes, but there was no significant difference of 131 I-hippuran excretion in 60 minutes compared with that of normal renogram group. 3) In the group showing unilateral non-functioning pattern of 131 I-hippuran renogram in one side and normal pattern in the other side there was found to be no difference in 131 I-hippuran excretion amount compared with that of normal renogram group. 4) It was evident from these experimental study that 131 I-hippuran renogram was considered as a good examination method for the evaluation of obstructive uropathy, and if one side kidney was intact it might compensate for the other diseased kidney so far as to renal excretory function. It was also shown that the more severe the cancerous spread in the pelvic wall the more changes on 131 I-hippuran renogram.

  11. Standardization of 131I therapy for Graves disease

    International Nuclear Information System (INIS)

    Tang Jianlin; Li Yuying; Gao Liuyan; Tang Xiuping; Hu Hongyong

    2011-01-01

    Objective: To establish the normative and standard measures, to ensure medical safety and quality of care of the patients with Graves disease treated by 131 I therapy. Methods: Formulating and strictly implementing the medical organizational and technical measures of 131 I therapy for Graves disease and regular follow-up. Results: Receiving 131 I treatment of 104 patients, follow-up 6-36 months, no adverse events, the cure rate of 59.6%, the efficient rate is 99.9%. Conclusion: It is important guarantee for the medical quality and safety to standardize the 131 I therapy of Graves disease. (authors)

  12. Sub-Scale Re-entry Capsule Drop via High Altitude Balloons

    Data.gov (United States)

    National Aeronautics and Space Administration — The project objective is to develop and test a sub-scale version of the Maraia Entry Capsule on a high altitude balloon. The capsule is released at 100,000 ft. The...

  13. Development of glia and blood vessels in the internal capsule of rats.

    Science.gov (United States)

    Earle, K L; Mitrofanis, J

    1998-02-01

    We have explored two aspects of internal capsule development that have not been described previously, namely, the development of glia and of blood vessels. To these ends, we used antibodies to glial fibrillary acidic protein (GFAP) and to vimentin (to identify astrocytes and to radial glia) and Griffonia simplicifolia (lectin; to identify microglia and blood vessels). Further, we made intracardiac injections of Evans Blue to examine the permeability of this dye in the vessels of the internal capsule during neonatal development. Our results show that large numbers of radial glia, astrocytes and microglia are not labelled with these markers in the white matter of the internal capsule until about birth; very few are labelled earlier, during the critical stages of corticofugal and corticopetal axonal ingrowth (E15-E20). The large glial labelling in the internal capsule at birth is accompanied by a dense vascular innervation of the capsule; as with the glia, very few labelled patent vessels are seen earlier. After intracardiac injections of Evans Blue, we find that the blood vessels of the internal capsule are not particularly permeable to Evans Blue. At each age examined (P0, P5, P15), blood vessels are outlined very clearly and there is no diffuse haze of fluorescence within the extracellular space, which is indicative of a leaky vessel. There are three striking differences between the glial environment of the internal capsule and that of the adjacent thalamus. First, the internal capsule is never rich with radial glial fibres (vimentin- and GFAP-immunoreactive) during development (except at P0), whereas the thalamus has many radial fibres from very early development (E15-E17). Second, astrocytes (vimentin- and GFAP-immunoreactive) first become apparent in the internal capsule (E20-P0) well before they do in the thalamus (P15). Third, the internal capsule houses a large transient population of amoeboid microglia (P0-P22), whereas the thalamus does not; only ramified

  14. Internal Contamination by 131I in nuclear medicine department

    International Nuclear Information System (INIS)

    Chahed, N.; Mtimet, S.; Hammami, H.; Mhiri, A.

    1998-01-01

    Therapeutic applications in nuclear medicine use high activities of 131 I in sodium iodine liquid from which is volatile at ambient temperature. Besides external exposure there is, for the nuclear medicine personnel, an internal exposure risk induced by 131 iodine inhalation. So we tried to assess this risk among the personnel in a nuclear medicine department. We used direct method for measuring 131 radioactivity in vivo by external counting. Gamma ray detector with a Nal ( TI ) probe positioned near the thyroid gland allows investigation of 131 radioactivity. We realised 34 measurements among the personnel, two times at an interval of one month. The results indicate that an 131 iodine internal contamination is found. Estimated thyroid activities were ranging from 35 to 132 Bq. The highest activities has been found in the thyroid of the technicians involved in the administration of 131 iodine therapy. Therefore this values are lower than norms. This study must lead to the implementation control of the 131 iodine internal contamination in order to optimise the personnel protection in nuclear medicine departments (author)

  15. A legged anchoring mechanism for capsule endoscopes using micropatterned adhesives.

    Science.gov (United States)

    Glass, Paul; Cheung, Eugene; Sitti, Metin

    2008-12-01

    This paper presents a new concept for an anchoring mechanism to enhance existing capsule endoscopes. The mechanism consists of three actuated legs with compliant feet lined with micropillar adhesives to be pressed into the intestine wall to anchor the device at a fixed location. These adhesive systems are inspired by gecko and beetle foot hairs. Single-leg and full capsule mathematical models of the forces generated by the legs are analyzed to understand capsule performance. Empirical friction models for the interaction of the adhesives with an intestinal substrate were experimentally determined in vitro using dry and oil-coated elastomer micropillar arrays with 140 microm pillar diameter, 105 microm spacing between pillars, and an aspect ratio of 1:1 on fresh porcine small intestine specimens. Capsule prototypes were also tested in a simulated intestine environment and compared with predicted peristaltic loads to assess the viability of the proposed design. The experimental results showed that a deployed 10 gr capsule robot can withstand axial peristaltic loads and anchor reliably when actuation forces are greater than 0.27 N using dry micropillars. Required actuation forces may be reduced significantly by using micropillars coated with a thin silicone oil layer.

  16. A disposable and multifunctional capsule for easy operation of microfluidic elastomer systems

    International Nuclear Information System (INIS)

    Thorslund, Sara; Läräng, Thomas; Kreuger, Johan; Nguyen, Hugo; Barkefors, Irmeli

    2011-01-01

    The global lab-on-chip and microfluidic markets for cell-based assays have been predicted to grow considerably, as novel microfluidic systems enable cell biologists to perform in vitro experiments at an unprecedented level of experimental control. Nevertheless, microfluidic assays must, in order to compete with conventional assays, be made available at easily affordable costs, and in addition be made simple to operate for users having no previous experience with microfluidics. We have to this end developed a multifunctional microfluidic capsule that can be mass-produced at low cost in thermoplastic material. The capsule enables straightforward operation of elastomer inserts of optional design, here exemplified with insert designs for molecular gradient formation in microfluidic cell culture systems. The integrated macro–micro interface of the capsule ensures reliable connection of the elastomer fluidic structures to an external perfusion system. A separate compartment in the capsule filled with superabsorbent material is used for internal waste absorption. The capsule assembly process is made easy by integrated snap-fits, and samples within the closed capsule can be analyzed using both inverted and upright microscopes. Taken together, the capsule concept presented here could help accelerate the use of microfluidic-based biological assays in the life science sector. (technical note)

  17. Capsule endoscopy in neoplastic diseases

    Science.gov (United States)

    Pennazio, Marco; Rondonotti, Emanuele; de Franchis, Roberto

    2008-01-01

    Until recently, diagnosis and management of small-bowel tumors were delayed by the difficulty of access to the small bowel and the poor diagnostic capabilities of the available diagnostic techniques. An array of new methods has recently been developed, increasing the possibility of detecting these tumors at an earlier stage. Capsule endoscopy (CE) appears to be an ideal tool to recognize the presence of neoplastic lesions along this organ, since it is non-invasive and enables the entire small bowel to be visualized. High-quality images of the small-bowel mucosa may be captured and small and flat lesions recognized, without exposure to radiation. Recent studies on a large population of patients undergoing CE have reported small-bowel tumor frequency only slightly above that reported in previous surgical series (range, 1.6%-2.4%) and have also confirmed that the main clinical indication to CE in patients with small-bowel tumors is obscure gastrointestinal (GI) bleeding. The majority of tumors identified by CE are malignant; many were unsuspected and not found by other methods. However, it remains difficult to identify pathology and tumor type based on the lesion’s endoscopic appearance. Despite its limitations, CE provides crucial information leading in most cases to changes in subsequent patient management. Whether the use of CE in combination with other new diagnostic (MRI or multidetector CT enterography) and therapeutic (Push-and-pull enteroscopy) techniques will lead to earlier diagnosis and treatment of these neoplasms, ultimately resulting in a survival advantage and in cost savings, remains to be determined through carefully-designed studies. PMID:18785274

  18. Effect of preparation conditions on properties and permeability of chitosan-sodium hexametaphosphate capsules.

    Science.gov (United States)

    Angelova, N; Hunkeler, D

    2001-01-01

    Capsules were obtained by interpolymer complexation between chitosan (polycation) and sodium hexametaphosphate (SMP, oligoanion). The effect of the preparation conditions on the capsule characteristics was evaluated. Specifically, the influence of variables such as pH, ionic strength, reagent concentration, and additives on the capsule permeability properties was investigated using dextran as a model permeant. The capsule membrane permeability was found to increase by decreasing the chitosan/SMP ratio as well as adding mannitol to the oligoanion recipient bath. Increasing the ionic strength or the pH of the initial chitosan solution was also found to enhance the membrane permeability, moving the membrane exclusion limit to higher values. Generally, the capsules prepared tinder all tested conditions had a relatively low permeability which rarely exceeded a molecular cut-off of 40 kD based on dextran standards. Furthermore, the diffusion rate showed a strong temporal dependence, indicating that the capsules prepared under various conditions exhibit different apparent pore size densities on the surface. The results indicated that, in order to obtain the desired capsule mass-transfer properties, the preparation conditions should be carefully considered and adjusted. Adding a polyol as well as low salt amount (less than 0.15%) is preferable as a means of modulating the diffusion characteristics, without disturbing the capsule mechanical stability.

  19. SATCAP: a program for thermal-hydraulic design of saturated temperature capsule

    International Nuclear Information System (INIS)

    Harayama, Yasuo; Niimi, Motoji; Someya, Hiroyuki; Kobayashi, Toshiki.

    1988-02-01

    For material irradiation tests at JMTR, user's technical requirements are gradually becoming more rigid, permitting only a small temperature deviation from the desired during irradiation of test materials. As specimen temperature control equipment, several conception were proposed and some of them were translated into actual machines with the capsule having electrical seath heaters in it. This system is highly reliable unless the integrity of the heaters is threatened. However, in a test with the object of achieving a high exposure of specimen to neutrons, the break of a heater or deterioration of a heater caused by irradiation lowers the reliability of the system. To cope with this drawback, as a part of the irradiation technique improvement program, ''Satulated Temperature Capsule'' has been developing. This type capsule, in which the water suplied is boiled, bases on the conception of keeping the coolant at the saturated temperature facilitates the temperature control. Though there are various types of capsules employed at JMTR, the experience of the capsule into which the coolant is injected lacks. In designing, thermal performances have to fully understood. Therefore, a program was compiled to evaluate the thermal behavior in the capsule. The present report describes the calculation procedure and guides of input and output for the program. (author)

  20. Comparison of thallium-201, Tc-99m MIBI and I-131 scan in the follow-up assessment after I-131 ablative therapy in differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Kwon, Jae Sung; Lee, Sung Keun; Kim, Doe Min; Park, Sae Jong; Jang, Kyong Sun; Kim, Eun Sil; Kim, Chong Soon

    1999-01-01

    We conducted a comparative study to evaluate the diagnostic values of Tl-201, Tc-99m MIBI and I-131 scans in the follow-up assessment after ablative I-131 therapy in differentiated thyroid cancer. The study population consisted of 20 patients who underwent surgical removal of thyroid cancer and ablative radioactive iodine therapy, and followed by one or more times of I-131 retreatment (33 cases). In all patients, Tl-201, Tc-99m MIBI, diagnostic and therapeutic I-131 scans were performed and the results were analyzed retrospectively. Also serum thyroglobulin levels were measured in all patients. The final diagnosis of recurrent or metastatic thyroid cancer was determined by clinical, biochemical, radiologic and/or biopsy findings. Positive rates (PR) of Tc-99m MIBI, Tl-201, diagnostic and therapeutic I-131 scans in detecting malignant thyroid tissue lesions were 70% (19/27), 54% (15/28), 35% (17/48) and 63% (30/48), respectively. The PR in the group of 20 cases (28 lesions) who underwent concomitant Tl-201 and I-131 scans were in the order of therapeutic 131 scan 71%, Tl-201 scan 54% and diagnostic I-131 scan 36%. There was no statistically significant difference between Tl-201 and diagnostic I-131 scans (p>0.05). In the group of 20 cases (27 lesions) who underwent concomitant Tc-99m MIBI and I-131 scans, the PR were in the order of Tc-99m MIBI scan 70%, I-131 therapeutic scan 52% and I-131 diagnostic scan 33%. The PR of Tc-99m MIBI was significantly higher than that of diagnostic I-131 scan (p<0.05). Tc-99m MIBI scan is superior to diagnostic I-131 scan in detecting recurrent or metastatic thyroid cancer following ablation therapy in patients with differentiated thyroid cancer. Tl-201 scan did not showed significantly higher positive rate than diagnostic I-131 scan. Instead of diagnostic I-131 scan before the I-131 retreatment, Tc-99m MIBI scan without discontinuing thyroid hormone replacement would be a prudent and effective approach in the management of these

  1. Capsule Development and Utilization for Material Irradiation Tests

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Kang, Y. H.; Cho, M. S. (and others)

    2007-06-15

    The essential technology for an irradiation test of materials and nuclear fuel has been successively developed and utilized to meet the user's requirements in Phase I(July 21, 1997 to March 31, 2000). It enables irradiation tests to be performed for a non-fissile material under a temperature control(300{+-}10 .deg. C) in a He gas environment, and most of the irradiation tests for the internal and external users are able to be conducted effectively. The basic technology was established to irradiate a nuclear fuel, and a creep capsule was also developed to measure the creep property of a material during an irradiation test in HANARO in Phase II(April 1, 2000 to March 31, 2003). The development of a specific purpose capsule, essential technology for a re-irradiation of a nuclear fuel, advanced technology for an irradiation of materials and a nuclear fuel were performed in Phase III(April 1, 2003 to February 28, 2007). Therefore, the technology for an irradiation test was established to support the irradiation of materials and a nuclear fuel which is required for the National Nuclear R and D Programs. In addition, an improvement of the existing capsule design and fabrication technology, and the development of an instrumented capsule for a nuclear fuel and a specific purpose will be able to satisfy the user's requirements. In order to support the irradiation test of materials and a nuclear fuel for developing the next generation nuclear system, it is also necessary to continuously improve the design and fabrication technology of the existing capsule and the irradiation technology.

  2. Remote-welding technique for assembling in-pile IASCC capsule in hot cell

    International Nuclear Information System (INIS)

    Kawamata, Kazuo; Ishii, Toshimitsu; Kanazawa, Yoshiharu; Iwamatsu, Shigemi; Ohmi, Masao; Shimizu, Michio; Matsui, Yoshinori; Saito, Jun-ichi; Ugachi, Hirokazu; Kaji, Yoshiyuki; Tsukada, Takashi

    2006-01-01

    In order to investigate behavior of the irradiation assisted stress corrosion cracking (IASCC) caused by the simultaneous effects of neutron irradiation and high temperature water environment in such a light water reactor (LWR), it is necessary to perform crack growth tests in an in-pile IASCC capsule irradiated in the Japan Materials Testing Reactor (JMTR). The development of the remote-welding technique is essential for remotely assembling the in-pile IASCC capsule installing the pre-irradiated CT specimens. This report describes a new remote-welding machine developed for assembling the in-pile IASCC capsule. The remote-welding technique that the capsule tube is rotated light under the fixed torch was applied to the machine for the welding of thick and large-diameter tubes. The assembly work of four in-pile IASCC capsules having pre-irradiated CT specimens in the hot cell was succeeded for performing the crack growth test under the neutron irradiation in JMTR. The irradiation test of two capsules has been already finished in JMTR without problems. (author)

  3. Development of target capsules for muon catalyzed fusion experiments

    International Nuclear Information System (INIS)

    Watts, K.D.; Jones, S.E.; Caffrey, A.J.

    1983-01-01

    A series of Muon Catalyzed Fusion experiments has been conducted at the Los Alamos Meson Physics Facility to determine how many fusion reactions one muon would catalyze under various temperature, pressure, contamination, and tritium concentration conditions. Target capsules to contain deuterium and tritium at elevated temperatures and pressures were engineered for a maximum temperature of 540 K (512 0 F) and a maximum pressure of 103 MPa (15,000 psig). Experimental data collected with these capsules indicated that the number of fusion reactions per muon continued to increase with temperature up to the 540-K design limit. Theory had indicated that the reaction rate should peak at approximately 540 K, but this was not confirmed during the experiments. A second generation of capsules which have a maximum design temperature of 800 K (980 0 F) and a maximum design pressure of 103 MPa (15,000 psig) has now been engineered. These new capsules will be used to further study the muon catalysis rate versus deuterium-tritium mixture temperature

  4. High spin structure in 130,131Ba

    International Nuclear Information System (INIS)

    Kaur, Navneet; Kumar, A.; Singh, Amandeep; Kumar, S.; Kaur, Rajbir; Singh, Varinderjit; Behera, B.R.; Singh, K.P.; Singh, G.; Mukherjee, G.; Sharma, H.P.; Kumar, Suresh; Kumar Raju, M.; Madhusudhan Rao, P.V.; Muralithar, S.; Singh, R.P.; Kumar, Rakesh; Madhvan, N.; Bhowmik, R.K.

    2014-01-01

    High spin states of 130,131 Ba have been investigated via fusion evaporation reactions 122 Sn( 13 C,4n) 131 Ba and 122 Sn( 13 C, 5n) 130 Ba at E beam =65 MeV. The level schemes of 130,131 Ba have been extended by placing several new γ transitions. A few interband transitions connecting two negative-parity bands, which are the experimental fingerprints of signature partners, have been established in 130 Ba. Spin and parity of a side band have been assigned in 131 Ba and this dipole band is proposed to have a three-quasiparticle configuration, νh 11/2 x πh 11/2 x πg 7/2 . The observed band structures and nuclear shape evolution as a function of the angular momentum have been discussed in the light of Total-Routhian-Surface calculations. (orig.)

  5. Development and Testing of a Magnetically Actuated Capsule Endoscopy for Obesity Treatment.

    Directory of Open Access Journals (Sweden)

    Thanh Nho Do

    Full Text Available Intra-gastric balloons (IGB have become an efficient and less invasive method for obesity treatment. The use of traditional IGBs require complex insertion tools and flexible endoscopes to place and remove the balloon inside the patient's stomach, which may cause discomfort and complications to the patient. This paper introduces a new ingestible weight-loss capsule with a magnetically remote-controlled inflatable and deflatable balloon. To inflate the balloon, biocompatible effervescent chemicals are used. As the source of the actuation is provided via external magnetic fields, the magnetic capsule size can be significantly reduced compared to current weight-loss capsules in the literature. In addition, there are no limitations on the power supply. To lose weight, the obese subject needs only to swallow the magnetic capsule with a glass of water. Once the magnetic capsule has reached the patient's stomach, the balloon will be wirelessly inflated to occupy gastric space and give the feeling of satiety. The balloon can be wirelessly deflated at any time to allow the magnetic capsule to travel down the intestine and exit the body via normal peristalsis. The optimal ratio between the acid and base to provide the desired gas volume is experimentally evaluated and presented. A prototype capsule (9.6mm x 27mm is developed and experimentally validated in ex-vivo experiments. The unique ease of delivery and expulsion of the proposed magnetic capsule is slated to make this development a good treatment option for people seeking to lose excess weight.

  6. Temporary presence of myofibroblasts in human elbow capsule after trauma

    NARCIS (Netherlands)

    Doornberg, Job N.; Bosse, Tjalling; Cohen, Mark S.; Jupiter, Jesse B.; Ring, David; Kloen, Peter

    2014-01-01

    Elbow stiffness is a common complication after elbow trauma. The elbow capsule is often thickened, fibrotic, and contracted at the time of surgical release. The limited studies available suggest that the capsule is contracted because of fibroblast-to-myofibroblast differentiation. We hypothesize

  7. Non-small-bowel abnormalities identified during small bowel capsule endoscopy

    NARCIS (Netherlands)

    Hoedemakers, Reinier; Westerhof, Jessie; Weersma, Rinse K.; Koornstra, Jan J.

    2014-01-01

    AIM: To investigate the incidence of non-small-bowel abnormalities in patients referred for small bowel capsule endoscopy, this single center study was performed. METHODS: Small bowel capsule endoscopy is an accepted technique to investigate obscure gastrointestinal bleeding. This is defined as

  8. Local delivery of 131I-MIBG to treat peritoneal neuroblastoma

    International Nuclear Information System (INIS)

    Kinuya, Seigo; Li, Xiao-Feng; Yokoyama, Kunihiko; Michigishi, Takatoshi; Tonami, Norihisa; Mori, Hirofumi; Shiba, Kazuhiro; Watanabe, Naoto; Shuke, Noriyuki; Bunko, Hisashi

    2003-01-01

    Internal radiotherapy involving systemic administration of iodine-131 metaiodobenzylguanidine ( 131 I-MIBG) in neural crest tumours such as neuroblastoma has shown considerable success. Although peritoneal seeding of neuroblastoma occurs less often than metastases to organs such as the liver, no effective treatments exist in this clinical setting. Previous reports have demonstrated the effectiveness of peritoneal application of chemotherapeutic drugs or radiolabelled monoclonal antibodies in several kinds of carcinomas. Local delivery of 131 I-MIBG should produce more favourable dosimetry in comparison with its systemic administration in the treatment of peritoneal neuroblastoma. In the current investigation, a peritoneal model of neuroblastoma was established in Balb/c nu/nu mice by i.p. injection of SK-N-SH neuroblastoma cells. Two weeks after cell inoculation, comparative biodistribution studies were performed following i.v. or i.p. administration of 131 I-MIBG. Mice were treated with 55.5 MBq of 131 I-MIBG administered either i.v. or i.p. at 2 weeks. Intraperitoneal injection of 131 I-MIBG produced significantly higher tumour accumulation than did i.v. injection (P 131 I-MIBG failed to improve the survival of mice; mean survival of untreated mice and mice treated with i.v. administration of 131 I-MIBG was 59.3±3.9 days and 60.6±2.8 days, respectively. On the other hand, radiotherapy delivered via i.p. administration of 131 I-MIBG prolonged survival of mice to 94.7±17.5 days (P 131 I-MIBG therapy). Radiation doses absorbed by tumours at 55.5 MBq of 131 I-MIBG were estimated to be 4,140 cGy with i.p. injection and 450 cGy with i.v. injection. These results indicate the benefits of locoregional delivery of 131 I-MIBG in the treatment of peritoneal neuroblastoma. (orig.)

  9. Transport of solid commodities via freight pipeline: freight pipeline technology. Volume II. First year final report. [Slurry, pneumatic, pneumo-capsule, and hydro-capsule

    Energy Technology Data Exchange (ETDEWEB)

    Zandi, I.; Gimm, K.K.

    1976-07-01

    In order to determine the feasibility of pipeline as an intercity freight transportation mode, it was necessary to examine its technological feasibility and reliability. This report describes the technology of the major generic freight pipelines in terms of both historical and current trends and operations. Additionally, it presents a state-of-the-art review of calculating energy requirements of various generic freight pipelines. It was concluded that slurry and pneumatic pipelines are technologically feasible and reliable. There are many commercial installations of both types operating around the world. Based on European experience with pneumo-capsule pipelines for mail delivery and Russian gravel- and sand-transport installations, it appears that a pneumo-capsule pipeline is a technologically feasible and operationally reliable mode for transport of solids. Since no commercial pneumo-capsule pipeline installations yet exist in the U.S., it seems desirable that a service demonstration of the advantages and feasibility of this mode of transport be undertaken to attract the shippers' confidence. Hydro-capsule pipelines are technologically feasible, but its reliability within a commercial environment remains to be tested.

  10. Abundance and co-occurrence of extracellular capsules increase environmental breadth: Implications for the emergence of pathogens.

    Science.gov (United States)

    Rendueles, Olaya; Garcia-Garcerà, Marc; Néron, Bertrand; Touchon, Marie; Rocha, Eduardo P C

    2017-07-01

    Extracellular capsules constitute the outermost layer of many bacteria, are major virulence factors, and affect antimicrobial therapies. They have been used as epidemiological markers and recently became vaccination targets. Despite the efforts to biochemically serotype capsules in a few model pathogens, little is known of their taxonomic and environmental distribution. We developed, validated, and made available a computational tool, CapsuleFinder, to identify capsules in genomes. The analysis of over 2500 prokaryotic genomes, accessible in a database, revealed that ca. 50% of them-including Archaea-encode a capsule. The Wzx/Wzy-dependent capsular group was by far the most abundant. Surprisingly, a fifth of the genomes encode more than one capsule system-often from different groups-and their non-random co-occurrence suggests the existence of negative and positive epistatic interactions. To understand the role of multiple capsules, we queried more than 6700 metagenomes for the presence of species encoding capsules and showed that their distribution varied between environmental categories and, within the human microbiome, between body locations. Species encoding capsules, and especially those encoding multiple capsules, had larger environmental breadths than the other species. Accordingly, capsules were more frequent in environmental bacteria than in pathogens and, within the latter, they were more frequent among facultative pathogens. Nevertheless, capsules were frequent in clinical samples, and were usually associated with fast-growing bacteria with high infectious doses. Our results suggest that capsules increase the environmental range of bacteria and make them more resilient to environmental perturbations. Capsules might allow opportunistic pathogens to profit from empty ecological niches or environmental perturbations, such as those resulting from antibiotic therapy, to colonize the host. Capsule-associated virulence might thus be a by-product of environmental

  11. Abundance and co-occurrence of extracellular capsules increase environmental breadth: Implications for the emergence of pathogens.

    Directory of Open Access Journals (Sweden)

    Olaya Rendueles

    2017-07-01

    Full Text Available Extracellular capsules constitute the outermost layer of many bacteria, are major virulence factors, and affect antimicrobial therapies. They have been used as epidemiological markers and recently became vaccination targets. Despite the efforts to biochemically serotype capsules in a few model pathogens, little is known of their taxonomic and environmental distribution. We developed, validated, and made available a computational tool, CapsuleFinder, to identify capsules in genomes. The analysis of over 2500 prokaryotic genomes, accessible in a database, revealed that ca. 50% of them-including Archaea-encode a capsule. The Wzx/Wzy-dependent capsular group was by far the most abundant. Surprisingly, a fifth of the genomes encode more than one capsule system-often from different groups-and their non-random co-occurrence suggests the existence of negative and positive epistatic interactions. To understand the role of multiple capsules, we queried more than 6700 metagenomes for the presence of species encoding capsules and showed that their distribution varied between environmental categories and, within the human microbiome, between body locations. Species encoding capsules, and especially those encoding multiple capsules, had larger environmental breadths than the other species. Accordingly, capsules were more frequent in environmental bacteria than in pathogens and, within the latter, they were more frequent among facultative pathogens. Nevertheless, capsules were frequent in clinical samples, and were usually associated with fast-growing bacteria with high infectious doses. Our results suggest that capsules increase the environmental range of bacteria and make them more resilient to environmental perturbations. Capsules might allow opportunistic pathogens to profit from empty ecological niches or environmental perturbations, such as those resulting from antibiotic therapy, to colonize the host. Capsule-associated virulence might thus be a by

  12. NMR relaxation dispersion of Miglyol molecules confined inside polymeric micro-capsules.

    Science.gov (United States)

    Nechifor, Ruben; Ardelean, Ioan; Mattea, Carlos; Stapf, Siegfried; Bogdan, Mircea

    2011-11-01

    Frequency dependent NMR relaxation studies have been carried out on Miglyol molecules confined inside core shell polymeric capsules to obtain a correlation between capsule dimension and the measurable parameters. The polymeric capsules were prepared using an interfacial polymerization technique for three different concentrations of Miglyol. It was shown that the variation of Miglyol concentration influences the capsule dimension. Their average size was estimated using the pulsed field gradient diffusometry technique. The relaxation dispersion curves were obtained at room temperature by a combined use of a fast field cycling instrument and a high-field instrument. The frequency dependence of relaxation rate shows a transition from a diffusion-limited to a surface-limited relaxation regime. Copyright © 2011 John Wiley & Sons, Ltd.

  13. [sup 131]I-metaiodobenzylguanidine therapy for malignant pheochromocytoma

    Energy Technology Data Exchange (ETDEWEB)

    Sakahara, Harumi; Saga, Tsuneo; Hosono, Makoto; Kobayashi, Hisataka; Konishi, Junji (Kyoto Univ. (Japan). Faculty of Medicine); Endo, Keigo

    1994-05-01

    [sup 131]I-metaiodobenzylguanidine (MIBG) therapy was given to five patients with malignant pheochromocytoma. The patients received 1-3 doses of 3.33-4.625 GBq (total dose: 3.7 to 10.73 GBq). Partial tumor regression was observed in two patients, the tumor was unchanged in two patients, and slow progression was noted in one patient. Marked improvement in clinical symptoms was achieved in four patients. The other patients had no symptoms before [sup 131]I-MIBG treatment, but the serum epinephrine and dopamine decreased. There were no severe untoward responses in four patients. However, one patient developed transient but severe orthostatic hypotension, hypertension, and hyperglycemia from 1 week to 1 month after [sup 131]I-MIBG administration. Although complete remission was not obtained, all the patients achieved some benefit from [sup 131]I-MIBG therapy. Thus, [sup 131]I-MIBG appears to be useful for the palliation of malignant pheochromocytoma. (author).

  14. Visualization of adrenocortical carcinoma with 131I-Adosterol

    International Nuclear Information System (INIS)

    Maruoka, Shin; Nakamura, Mamoru

    1987-01-01

    There are very few literatures on successful visualization of adrenocortical carcinoma by means of 131 I-iodocholesterol scintigraphy, although many reports have referred to utility of 131 I-iodocholesterol scintigraphy for adrenal disorders. Since 1976, we have experienced 4 cases of adrenocortical carcinoma which were delineated by 131 I-6β-iodomethyl-19-norcholesterol ( 131 I-Adosterol). Three of 4 cases were adrenocortical carcinoma with Cushing's syndrome, and one was adrenocortical carcinoma with adrenogenital syndrome. In 3 cases of cortisol secreting adrenocortical carcinoma, uptake in the tumor and lack of uptake in the contralateral adrenal gland were seen. Faint to moderate uptakes were observed in the 2 cases, but another one showed as high uptake as seen in adenoma. Patient with androgen secreting adrenocortical carcinoma had increased uptake in the tumor and showed faint uptake in the contralateral adrenal gland. Intensity of 131 I-Adosterol uptake in adrenocortical carcinoma seems to depend on the extent of tumor necrosis, cell differentiation and function. (author)

  15. Stability of /sup 131/I--thyroxine and of /sup 131/I-tri-iodothyronine: the influence of radiolytic disintegration on certain diagnostic tests

    Energy Technology Data Exchange (ETDEWEB)

    Reviczky, A.L.; Szanto, L.

    1974-01-01

    The blood-protein fractions responsible for the transport of thyroid hormones (TBG, TBPA, TBA) were assayed for their thyroxine-binding capacity in the serum of the same control subject over a one-year period, by a procedure based on the isotope-dilution technique. In the dilutions of /sup 131/I--T/sub 4/ (Amersham RCC) required for the procedure, the ratio /sup 131/I--T/sub 4/:/sup 131/I--T/sub 3/ was measured in every case. Parallel with the accumulation of /sup 131/I--T/sub 3/ resulting from deiodination of /sup 131/I--T/sub 4/, the binding capacity of the individual fractions was found to have shifted from TBG to TBPA. The fact that, in contrast to the principle of the isotope-dilution technique, the labelled substance and the non-radioactive T/sub 4/ were partly different, suggests that the measurements of radioactivity do not reflect the true binding conditions of T/sub 4/. Successive batches of /sup 131/I--T/sub 3/ were examined in the same manner, and the values of the Hamolsky test were determined in the same serum. The figures displayed little variations and /sup 131/I--T/sub 3/ was also found significantly more stable than /sup 131/I--T/sub 4/. Thus, the Hamolsky test was found to represent a fairly reliable indicator of thyroid function, in contrast to measurement of the T/sub 4/-binding capacity of the blood protein fractions by the isotope-dilution technique, the results of which are uncertain and therefore inconclusive in both clinical and therapeutic respects. It is suggested that the /sup 131/I--T/sub 4/ serving for the assays should be supplied as a substance and diluted before use, but not later than a few days after preparation. The advantages of doublet tagging are pointed out.

  16. X-ray drive of beryllium capsule implosions at the National Ignition Facility

    International Nuclear Information System (INIS)

    Wilson, D C; Yi, S A; Simakov, A N; Kline, J L; Kyrala, G A; Olson, R E; Zylstra, A B; Dewald, E L; Tommasini, R; Ralph, J E; Strozzi, D J; Celliers, P M; Schneider, M B; MacPhee, A G; Callahan, D A; Hurricane, O A; Milovich, J L; Hinkel, D E; Rygg, J R; Rinderknecht, H G

    2016-01-01

    National Ignition Facility experiments with beryllium capsules have followed a path begun with “high-foot” plastic capsule implosions. Three shock timing keyhole targets, one symmetry capsule, a streaked backlit capsule, and a 2D backlit capsule were fielded before the DT layered shot. After backscatter subtraction, laser drive degradation is needed to match observed X-ray drives. VISAR measurements determined drive degradation for the picket, trough, and second pulse. Time dependence of the total Dante flux reflects degradation of the of the third laser pulse. The same drive degradation that matches Dante data for three beryllium shots matches Dante and bangtimes for plastic shots N130501 and N130812. In the picket of both Be and CH hohlraums, calculations over-estimate the x-ray flux > 1.8 keV by ∼100X, while calculating the total flux correctly. In beryllium calculations these X-rays cause an early expansion of the beryllium/fuel interface at ∼3 km/s. VISAR measurements gave only ∼0.3 km/s. The X-ray drive on the Be DT capsule was further degraded by an unplanned decrease of 9% in the total picket flux. This small change caused the fuel adiabat to rise from 1.8 to 2.3. The first NIF beryllium DT implosion achieved 29% of calculated yield, compared to CH capsules with 68% and 21%. (paper)

  17. Hydrochlorothiazide-induced 131I excretion facilitated by salt and water

    International Nuclear Information System (INIS)

    Beyer, K.H. Jr.; Fehr, D.M.; Gelarden, R.T.; White, W.J.; Lang, C.M.; Vesell, E.S.

    1981-01-01

    Salt intake is restricted under clinical conditions for which thiazide diuretics are customarily used. Dietary iodide intake offsets any effect of thiazide on iodide loss. However, our correlation coefficients relating Na+ to Cl- to I- excretion indicate that as thiazide administration or sodium chloride intake increases renal Na+ and Cl- excretion, I- reabsorption by the nephron coordinately decreases. Increased sodium chloride and water intake by the dog doubled I-excretion rates. Hydrochlorothiazide increased the sodium chloride and water enhanced I-excretion rate as much as eight-fold. Without added NaCl, hydrochlorothiazide increased the excretion rate of 131I by three- to eightfold, acutely. Within five to seven days after 131I oral administration, hydrochlorothiazide (1 or 2 mg/kg twice daily) doubled the rate of 131I disappearance from plasma, reduced the fecal output of 131I, and increased its rate of renal excretion. When hydrochlorothiazide was administered, as much 131I was excreted in the first 24 hours as occurred in 48 hours when sodium chloride and water were given without hydrochlorothiazide. Thiazide administration in customary clinical dosage twice a day with substantial sodium chloride and water for the first two days after exposure to 131I, should therefore facilitate the safe excretion of 131I. This accelerated removal of 131I might be enhanced even more if thyroid uptake of 131I is blocked by administration of potassium iodide, as judged by the greater 131I recovery from thyroidectomized dogs

  18. The development of the nasal capsule of the silver carp ...

    African Journals Online (AJOL)

    The development of the nasal capsule, including the procartilaginous as well as some mesenchymatous developmental stages, is described in the chinese silver carp,. Hypophthalmichthys molitrix (VaL). In the nasal capsule a primitive feature, namely the presence of a complete paraphysial bridge was observed.

  19. Fabrication and operation of HFIR-MFE RB* spectrally tailored irradiation capsules

    International Nuclear Information System (INIS)

    Longest, A.W.; Pawel, J.E.; Heatherly, D.W.; Sitterson, R.G.; Wallace, R.L.

    1993-01-01

    Fabrication and operation of four HFIR-MFE RB * capsules (60, 200, 330, and 400 degrees C) to accommodate MFE specimens previously irradiated in spectrally tailored experiments in the ORR are proceeding satisfactorily. With the exception of the 60 degrees C capsule, where the test specimens were in direct contact with the reactor cooling water, specimen temperatures (monitored by 21 thermocouples) are controlled by varying the thermal conductance of a thin gap region between the specimen holder outer sleeve and containment tube. Irradiation of the 60 and 330 degrees C capsules, which started on July 17, 1990, was completed on November 14, 1992, after 24 cycles of irradiation to an incremental damage level of approximately 10.9 displacements per atom (dpa). Assembly of the follow-up 200 and 400 degrees C capsules was completed in November 1992, and their planned 20-cycle irradiation to approximately 9.1 incremental dpa was started on November 21, 1992. As of February 11, 1993, the 200 and 400 degrees C capsules had successfully completed three cycles of irradiation to approximately 1.4 incremental dpa

  20. 20 CFR 1001.131 - Secretary's annual report to Congress.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Secretary's annual report to Congress. 1001.131 Section 1001.131 Employees' Benefits OFFICE OF THE ASSISTANT SECRETARY FOR VETERANS' EMPLOYMENT... Compliance § 1001.131 Secretary's annual report to Congress. The Secretary shall report, after the end of...

  1. 26 CFR 1.381(c)(13)-1 - Involuntary conversions.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 4 2010-04-01 2010-04-01 false Involuntary conversions. 1.381(c)(13)-1 Section 1.381(c)(13)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Insolvency Reorganizations § 1.381(c)(13)-1 Involuntary conversions...

  2. Analysis of 131I therapy in 71 patients with hyperthyroidism

    International Nuclear Information System (INIS)

    Wang Ping; Chen Zequan; Wang Yuanzhi; Ye Shiqing

    2001-01-01

    Objective: To evaluate the clinical significance of iodine-131 treatment in patients with hyperthyroidism. Methods: The dose of 131 I was determined according to thyroid absorption of 131 I at 24 hrs post administration and thyroid weight estimated in ECT examination. Results: One dose cure rate of 131 I treatment was 96% (68/71). Hypothyroidism occurred in 3 of 71 patients (4%) in one year after administration. No other serious complication was observed. Conclusion: The therapeutic effect of 131 I in treating hyperthyroidism was quite encouraging. The administration regime was also simple

  3. Imaging of High-Z doped, Imploded Capsule Cores

    Science.gov (United States)

    Prisbrey, Shon T.; Edwards, M. John; Suter, Larry J.

    2006-10-01

    The ability to correctly ascertain the shape of imploded fusion capsules is critical to be able to achieve the spherical symmetry needed to maximize the energy yield of proposed fusion experiments for the National Ignition Facility. Implosion of the capsule creates a hot, dense core. The introduction of a high-Z dopant into the gas-filled core of the capsule increases the amount of bremsstrahlung radiation produced in the core and should make the imaging of the imploded core easier. Images of the imploded core can then be analyzed to ascertain the symmetry of the implosion. We calculate that the addition of Ne gas into a deuterium gas core will increase the amount of radiation emission while preserving the surrogacy of the radiation and hydrodynamics in the indirect drive NIF hohlraum in the proposed cryogenic hohlraums. The increased emission will more easily enable measurement of asymmetries and tuning of the implosion.

  4. Alternative hot spot formation techniques using liquid deuterium-tritium layer inertial confinement fusion capsules

    International Nuclear Information System (INIS)

    Olson, R. E.; Leeper, R. J.

    2013-01-01

    The baseline DT ice layer inertial confinement fusion (ICF) ignition capsule design requires a hot spot convergence ratio of ∼34 with a hot spot that is formed from DT mass originally residing in a very thin layer at the inner DT ice surface. In the present paper, we propose alternative ICF capsule designs in which the hot spot is formed mostly or entirely from mass originating within a spherical volume of DT vapor. Simulations of the implosion and hot spot formation in two DT liquid layer ICF capsule concepts—the DT wetted hydrocarbon (CH) foam concept and the “fast formed liquid” (FFL) concept—are described and compared to simulations of standard DT ice layer capsules. 1D simulations are used to compare the drive requirements, the optimal shock timing, the radial dependence of hot spot specific energy gain, and the hot spot convergence ratio in low vapor pressure (DT ice) and high vapor pressure (DT liquid) capsules. 2D simulations are used to compare the relative sensitivities to low-mode x-ray flux asymmetries in the DT ice and DT liquid capsules. It is found that the overall thermonuclear yields predicted for DT liquid layer capsules are less than yields predicted for DT ice layer capsules in simulations using comparable capsule size and absorbed energy. However, the wetted foam and FFL designs allow for flexibility in hot spot convergence ratio through the adjustment of the initial cryogenic capsule temperature and, hence, DT vapor density, with a potentially improved robustness to low-mode x-ray flux asymmetry

  5. 131I-BSP liver function test by BSP tolerance

    International Nuclear Information System (INIS)

    Kanda, Koichi

    1974-01-01

    131 I-BSP liver function test after BSP intravenous tolerance was discussed, assuming that the reason why measurements of 131 I-BSP retention rate at 30 minutes and 131 I-BSP disappearance rate in blood showed respectable overlapping between normal group and group with slight liver disorders as compared with BSP test and the reason why differential diagnosis was difficult were due to underestimate of tolerance volume of 131 I-BSP. 131 I-BSP was observed with time as to 70 persons with normal liver function and 257 cases of liver diseases, using 5, 3 and 2 mg of non-radioactive BSP tolerance volume per kilogram of body weight. 131 I-BSP retention rate at 30 minutes and 131 I-BSP disappearance rate in blood are possible to separate overlapping over control in each measurement value at 3-5 mg/kg of tolerance, and in comparison of 3 mg and 5 mg, the latter showed a little excellent result. So, it was decided that tolerance of 3 mg/kg was a proper dose, considering tolerance to liver cells. 131 I-BSP retention rate at 30 minutes was a little excellent in accuracy and disappearance rate in blood after BSP tolerance is simple and profitable for practical use because collection of blood was only one time and measurement could be made with whole blood. As mentioned above, this method is seemed to be useful to practice of liver function test. (Kanao, N.)

  6. SATCAP-B: a program for thermal-hydraulic design of 'Saturated Temperature Capsule'

    International Nuclear Information System (INIS)

    Harayama, Yasuo; Someya, Hiroyuki; Niimi, Motoji

    1989-11-01

    As an advanced irradiation technique, the JMTR (Japan Materials Testing Reactor) project is developing a 'Saturated Temperature Capsule' which water is injected in and boiled. When the water is kept at a constant pressure, the water temperature does not become higher than the saturated temperature. This type capsule is based on the conception of keeping the coolant to the saturated temperature and using the temperature control. In designing the capsule in which the inner coolant is injected, thermal performances have to be understood as exactly as possible. Then, a program (named SATCAP) was compiled to graps the thermal performance within the capsule. On the other hand, a 'Saturated Temperature Capsule' was made and irradiated in the JMTR core. It was indicated from supplied water temperatures recorded by thermo-couples attached in the capsule that heat transfer coefficients prefered models due to natural convection to models incorporated in the initial version of the program. Then, the program was revised by adding mainly heat transfer model based on natural convection. The present report describes the calculation procedure and guides of input and output for the revised program (SATCAP version-B). (author)

  7. Mitigate the tent-induced perturbation in ignition capsules by supersonic radiation propagation

    Science.gov (United States)

    Dai, Zhensheng; Gu, Jianfa; Zheng, Wudi

    2017-10-01

    In the inertial confinement fusion (ICF) scheme, to trap the alpha particle products of the D-T reaction, the capsules needs to be imploded and compressed with high symmetry In the laser indirect drive scheme, the capsules are held at the center of high-Z hohlraums by thin membranes (tents). However, the tents are recognized as one of the most important contributors to hot spot asymmetries, areal density perturbations and reduced performance. To improve the capsule implosion performance, various alternatives such as the micro-scale rods, a larger fill-tube and a low-density foam layer around the capsule have been presented. Our simulations show that the radiation propagates supersonically in the low-density foam layer and starts to ablate the capsule before the perturbations induced by the tents reach the ablating fronts. The tent induced perturbations are remarkably weakened when they are propagating in the blow-off plasma.

  8. A hydrogel capsule as gate dielectric in flexible organic field-effect transistors

    Energy Technology Data Exchange (ETDEWEB)

    Dumitru, L. M.; Manoli, K.; Magliulo, M.; Torsi, L., E-mail: luisa.torsi@uniba.it [Department of Chemistry, University of Bari “Aldo Moro”, Via Orabona 4, Bari I-70126 (Italy); Ligonzo, T. [Department of Physics, University of Bari “Aldo Moro”, Via Orabona 4, Bari I-70126 (Italy); Palazzo, G. [Department of Chemistry, University of Bari “Aldo Moro”, Via Orabona 4, Bari I-70126 (Italy); Center of Colloid and Surface Science—CSGI—Bari Unit, Via Orabona 4, Bari I-70126 (Italy)

    2015-01-01

    A jellified alginate based capsule serves as biocompatible and biodegradable electrolyte system to gate an organic field-effect transistor fabricated on a flexible substrate. Such a system allows operating thiophene based polymer transistors below 0.5 V through an electrical double layer formed across an ion-permeable polymeric electrolyte. Moreover, biological macro-molecules such as glucose-oxidase and streptavidin can enter into the gating capsules that serve also as delivery system. An enzymatic bio-reaction is shown to take place in the capsule and preliminary results on the measurement of the electronic responses promise for low-cost, low-power, flexible electronic bio-sensing applications using capsule-gated organic field-effect transistors.

  9. Renal 131I-hippuran extraction in man

    DEFF Research Database (Denmark)

    Hutchings, M; Hesse, B; Grønvall, J

    2002-01-01

    This study examined the 131I-hippuran extraction fraction during baseline renal blood flow rates and at high flow rates induced by dopamine.......This study examined the 131I-hippuran extraction fraction during baseline renal blood flow rates and at high flow rates induced by dopamine....

  10. Radiopharmaceutical potential of I-131 labelled diazepam

    International Nuclear Information System (INIS)

    Yurt, F.; Unek, P.; Asikoglu, M.; Baggi, S.; Erener, G.; Ozkilic, H.; Uluc, F.; Tuglular, I.

    1998-01-01

    In this study, diazepam is a derivative of the 1.4 benzodiazepine family that the most widely used drug as anticonvulsant agent has been labeled with I-131, as a new radiopharmaceutical and its radiopharmaceutical potential has been determined. Labeling of diazepam has been performed by iodogen method and optimum labeling conditions have been determined. Optimum reaction conditions are 1 mg for iodogen amount; 1-5 mg for diazepam amount, 15-20 minutes for reaction time and room temperature for reaction temperature. Specific activity of labeled compound was 0,15 Ci/mmol level. N-octanol/water ratio was found 1.9 for 131 IDZ ( 131 I labeled diazepam). In vivo experiments have been carried out to determine radiopharmaceutical potentials of labeled compound. Biodistribution studies on rats showed that 131 IDZ have accumulated in kidneys, liver, lungs and brain tissues. Scintigraphic results taken with gamma camera on rabbits agree with biodistribution results of rats. (author)

  11. Thin film drainage between pre-inflated capsules or vesicles

    Science.gov (United States)

    Keh, Martin; Walter, Johann; Leal, Gary

    2013-11-01

    Capsules and vesicles are often used as vehicles to carry active ingredients or fragrance in drug delivery and consumer products and oftentimes in these applications the particles may be pre-inflated due to the existence of a small osmotic pressure difference between the interior and exterior fluid. We study the dynamics of thin film drainage between capsules and vesicles in flow as it is crucial to fusion and deposition of the particles and, therefore, the stability and effectiveness of the products. Simulations are conducted using a numerical model coupling the boundary integral method for the motion of the fluids and a finite element method for the membrane mechanics. For low capillary numbers, the drainage behavior of vesicles and capsules are approximately the same, and also similar to that of drops as the flow-independent and uniform tension due to pre-inflation dominates. The tension due to deformation caused by flow will become more important as the strength of the external flow (i.e. the capillary number) increases. In this case, the shapes of the thin film region are fundamentally different for capsules and vesicles, and the drainage behavior in both cases differs from a drop. Funded by P&G.

  12. A probabilistic method for determining the volume fraction of pre-embedded capsules in self-healing materials

    International Nuclear Information System (INIS)

    Lv, Zhong; Chen, Huisu

    2014-01-01

    Autonomous healing of cracks using pre-embedded capsules containing healing agent is becoming a promising approach to restore the strength of damaged structures. In addition to the material properties, the size and volume fraction of capsules influence crack healing in the matrix. Understanding the crack and capsule interaction is critical in the development and design of structures made of self-healing materials. Assuming that the pre-embedded capsules are randomly dispersed we theoretically model flat ellipsoidal crack interaction with capsules and determine the probability of a crack intersecting the pre-embedded capsules i.e. the self-healing probability. We also develop a probabilistic model of a crack simultaneously meeting with capsules and catalyst carriers in two-component self-healing system matrix. Using a risk-based healing approach, we determine the volume fraction and size of the pre-embedded capsules that are required to achieve a certain self-healing probability. To understand the effect of the shape of the capsules on self-healing we theoretically modeled crack interaction with spherical and cylindrical capsules. We compared the results of our theoretical model with Monte-Carlo simulations of crack interaction with capsules. The formulae presented in this paper will provide guidelines for engineers working with self-healing structures in material selection and sustenance. (paper)

  13. Polysaccharide capsule-mediated resistance to opsonophagocytosis in Klebsiella pneumoniae.

    OpenAIRE

    Domenico, P; Salo, R J; Cross, A S; Cunha, B A

    1994-01-01

    The polysaccharide capsule of Klebsiella pneumoniae is an important virulence factor that confers resistance to phagocytosis. The treatment of encapsulated bacteria with salicylate to inhibit capsule expression was found to enhance the phagocytosis of encapsulated bacteria by human neutrophils only in the presence of cell surface-specific antibodies. Both type-specific rabbit antisera and anticapsular human hyperimmune globulin were employed as opsonins. Salicylate significantly enhanced phag...

  14. Evaluation of hard gelatin capsules and hydroxypropyl methylcellulose containing ampicillin

    Directory of Open Access Journals (Sweden)

    Graziella Gonçalves Weigert

    2012-01-01

    Full Text Available This study aims to develop and evaluate formulations containing ampicillin in capsules of gelatin and hydroxypropyl methylcellulose (HPMC. Two formulations (A and B were developed. The final product quality was evaluated by testing for quality control and the results were in agreement with the Brazilian Pharmacopoeia. The formulations with HPMC capsules showed lower percentages of drug dissolved (99.67%, HPMC-A and 87.70%, HPMC-B than the gelatin (100.18%, GEL-A and 101.16% GEL-B. Because of the delay of the ampicillin release observed in the dissolution profiles, it becomes necessary to evaluate the drugs that can be conditioned in the HPMC capsules.

  15. Thyroid cancer from occupational exposures to iodine-131

    International Nuclear Information System (INIS)

    Shore, R.E.

    1983-01-01

    Studies of external irradiation, primarily of children, suggest that the thyroid gland is one of the most radiosensitive sites for carcinogenesis. However, it has generally been thought that 131 I confers much less risk (per rad) than external radiation because of its low dose-rate. A review of the epidemiologic literature indicates that age at irradiation is also an important variable in defining thyroid cancer risk, with a lesser risk at older ages. The available human studies are reasonably consistent in affirming that risks following 131 I are small. However, the data on 131 I exposure are too sparse, particularly for childhood exposure, to determine how much of the observed diminution in risk is due to older ages at exposure and how much is attributable to the characteristics of 131 I exposure per se, such as low dose-rate. Since most of the existing studies have inadequacies in design, dose levels, dosimetry or number of subjects, additional studies are needed before the risk assessment of 131 I at lower dose levels in adult workers can be regarded as definitive

  16. Prevalence and risk factors of adhesive capsulitis of the shoulder after breast cancer treatment.

    Science.gov (United States)

    Yang, Seoyon; Park, Dae Hwan; Ahn, Sei Hyun; Kim, Jisun; Lee, Jong Won; Han, Jun Young; Kim, Dong Kyu; Jeon, Jae Yong; Choi, Kyoung Hyo; Kim, Won

    2017-04-01

    The present study investigated the prevalence and risk factors of adhesive capsulitis of the shoulder in breast cancer patients between 13 and 18 months after surgery. This study included 271 women who underwent surgery for breast cancer with a postoperative period of 13-18 months. Current adhesive capsulitis was defined as restriction of external rotation and one or more additional directional restrictions with history of shoulder pain. Cumulative adhesive capsulitis was defined as current adhesive capsulitis or a previous history of adhesive capsulitis after breast cancer surgery. Multivariate logistic regression analysis was performed to examine associations between current or cumulative adhesive capsulitis and potential risk factors. Among the 271 study patients, 28 (10.3%) and 21 (7.7%) had cumulative or current adhesive capsulitis, respectively. The incidences of cumulative and current adhesive capsulitis were higher in those aged 50-59 years (odds ratio [OR], 9.912; 95% confidence interval [CI], 1.790-54.880; and OR, 12.395; 95% CI, 1.187-129.444, respectively) and those who underwent mastectomy (OR, 6.805; 95% CI, 1.800-25.733; and OR, 9.645; 95% CI, 2.075-44.829, respectively) or mastectomy with reconstruction (OR, 13.122; 95% CI, 2.488-69.218; and OR, 20.075; 95% CI, 2.873-140.261, respectively). Adhesive capsulitis of the shoulder is a common problem after breast cancer treatment. An age of 50-59 years and mastectomy are major risk factors for adhesive capsulitis, and breast reconstruction additionally increases the risk. Patients with these risk factors require greater attention for early diagnosis and proper treatment.

  17. Application of Bio-digestion for Capsule Gelatin-- From the Pharmaceutical Wastes to the Manure

    Science.gov (United States)

    Pan, C.; Huang, S.; Chang, Y.; Wen, J.

    2013-12-01

    The purpose of this study was to bio-digest the capsule gelatin from the waste of pharmaceutical processes such as cutting and stamping for capsule shells producing. We screened soil bacterial flora for capsule gelatin biolysis, and found the most competent one named Yuntech-7. A 15% (w/w) of capsule gelatin could fully digested by Yuntech-7 for 3 days growth with an N-limited medium in a 37°C incubator. In order to recycle and reuse the gelatin waste, the different percentages of capsule gelatin were co-composted with the vegetable residues to produce manure in an anaerobic fermentation by an extra Yuntech-7 inoculation. After 14 days incubation, we collected the filtrate to examine the contents of N, P, and K. The data shows that the P and K keep the same value by roughly between the blank and the control sets, but the total N values were approximately a 5-fold increase in 20% and a 10-fold increase in 40% of capsule gelatin integrated. We suggested that the capsule gelatin was majorly decomposed by Yuntech-7, because the total N value was no observable change in the capsule gelatin and vegetable residues co-compost with a Yuntech-7-free condition. We also performed some field tests using the capsule gelatin generated liquid manure, and the preliminary test shows the plants got great benefits on culture size and in environmental resistance. In conclusion, the process in bio-digestion of waste capsule gelatin by soil bacteria, Yuntech-7, was produced a valuable manure not only aliment the plants but also complement the soil bacterial populations.

  18. Generic Delivery of Payload of Nanoparticles Intracellularly via Hybrid Polymer Capsules for Bioimaging Applications

    Science.gov (United States)

    Sami, Haider; Maparu, Auhin K.; Kumar, Ashok; Sivakumar, Sri

    2012-01-01

    Towards the goal of development of a generic nanomaterial delivery system and delivery of the ‘as prepared’ nanoparticles without ‘further surface modification’ in a generic way, we have fabricated a hybrid polymer capsule as a delivery vehicle in which nanoparticles are loaded within their cavity. To this end, a generic approach to prepare nanomaterials-loaded polyelectrolyte multilayered (PEM) capsules has been reported, where polystyrene sulfonate (PSS)/polyallylamine hydrochloride (PAH) polymer capsules were employed as nano/microreactors to synthesize variety of nanomaterials (metal nanoparticles; lanthanide doped inorganic nanoparticles; gadolinium based nanoparticles, cadmium based nanoparticles; different shapes of nanoparticles; co-loading of two types of nanoparticles) in their hollow cavity. These nanoparticles-loaded capsules were employed to demonstrate generic delivery of payload of nanoparticles intracellularly (HeLa cells), without the need of individual nanoparticle surface modification. Validation of intracellular internalization of nanoparticles-loaded capsules by HeLa cells was ascertained by confocal laser scanning microscopy. The green emission from Tb3+ was observed after internalization of LaF3:Tb3+(5%) nanoparticles-loaded capsules by HeLa cells, which suggests that nanoparticles in hybrid capsules retain their functionality within the cells. In vitro cytotoxicity studies of these nanoparticles-loaded capsules showed less/no cytotoxicity in comparison to blank capsules or untreated cells, thus offering a way of evading direct contact of nanoparticles with cells because of the presence of biocompatible polymeric shell of capsules. The proposed hybrid delivery system can be potentially developed to avoid a series of biological barriers and deliver multiple cargoes (both simultaneous and individual delivery) without the need of individual cargo design/modification. PMID:22649489

  19. Generic delivery of payload of nanoparticles intracellularly via hybrid polymer capsules for bioimaging applications.

    Directory of Open Access Journals (Sweden)

    Haider Sami

    Full Text Available Towards the goal of development of a generic nanomaterial delivery system and delivery of the 'as prepared' nanoparticles without 'further surface modification' in a generic way, we have fabricated a hybrid polymer capsule as a delivery vehicle in which nanoparticles are loaded within their cavity. To this end, a generic approach to prepare nanomaterials-loaded polyelectrolyte multilayered (PEM capsules has been reported, where polystyrene sulfonate (PSS/polyallylamine hydrochloride (PAH polymer capsules were employed as nano/microreactors to synthesize variety of nanomaterials (metal nanoparticles; lanthanide doped inorganic nanoparticles; gadolinium based nanoparticles, cadmium based nanoparticles; different shapes of nanoparticles; co-loading of two types of nanoparticles in their hollow cavity. These nanoparticles-loaded capsules were employed to demonstrate generic delivery of payload of nanoparticles intracellularly (HeLa cells, without the need of individual nanoparticle surface modification. Validation of intracellular internalization of nanoparticles-loaded capsules by HeLa cells was ascertained by confocal laser scanning microscopy. The green emission from Tb(3+ was observed after internalization of LaF(3:Tb(3+(5% nanoparticles-loaded capsules by HeLa cells, which suggests that nanoparticles in hybrid capsules retain their functionality within the cells. In vitro cytotoxicity studies of these nanoparticles-loaded capsules showed less/no cytotoxicity in comparison to blank capsules or untreated cells, thus offering a way of evading direct contact of nanoparticles with cells because of the presence of biocompatible polymeric shell of capsules. The proposed hybrid delivery system can be potentially developed to avoid a series of biological barriers and deliver multiple cargoes (both simultaneous and individual delivery without the need of individual cargo design/modification.

  20. Influence of different excipients on the properties of hard gelatin capsules with metamizole sodium

    Directory of Open Access Journals (Sweden)

    Rogowska Magdalena

    2016-09-01

    Full Text Available Metamizole is an effective non-opioid analgesic drug used in the treatment of acute and chronic pain. Due to induced potentially life-threatening blood disorders, metamizole was withdrawn from market in many parts of the world, however, it is one of the most popular analgesics in Poland that is available as an over the counter drug. Patients tend to prefer capsules over tablets, as they are easier to swallow and taste better. The powder-filled capsules also have greater bioavailability and require less excipients, as compared to tablets. Polymic excipients are mainly used in capsule filling, and have influence upon the physico-chemical properties of the hard gelatin capsules and the powder formulation. The aim of the study was to determine whether various combinations of polymers impact the disintegration time and pharmaceutical availability of hard gelatin capsules with metamizole sodium. The results of our work demonstrated that the 80% of all active substance was released in all tested formulations within 15 minutes. Herein, the capsule containing lactose monohydrate had the longest release (4% after 2 min., while capsules containing mannitol had the fastest release (81.2% after 2 min.. Moreover, the addition of HPMC to capsules with lactose brought about a slight increase in the metamizole release rate, while the addition of PVP 30 to capsules with microcrystalline cellulose slightly accelerated release. This data suggests that the use of different polymers in capsules formulation brings about changes in the physical properties of powders and modifies the release profile of metamizole. In our study, the most preferred formulation was one containing microcrystalline cellulose (good powder properties and fairly fast release.

  1. U-turn type continuous irradiation method and device for radiation-irradiated capsule

    International Nuclear Information System (INIS)

    Kikuchi, Takayuki.

    1997-01-01

    A capsule to be irradiated is moved while being rotated in one of conveying shafts disposed in a reactor to conduct irradiation treatment. Then, the irradiated capsule is made U-turn in the reactor, inserted to the other conveying shaft and moved while being rotated to conduct irradiation treatment again, and then transported out of the reactor. The device comprises a rotational conveying shaft for moving the irradiated capsule while rotating it, a conveying gear for U-turning the irradiated capsule in the reactor and inserting it to the conveying shaft and a driving mechanism for synchronously rotating the conveying gear relative to the conveying shaft at a constant ratio. Mechanical time loss and manual operation time loss can be reduced upon loading and taking up of the irradiated capsule. Then, the amount of irradiation treatment per unit time is increased, and an optional neutron irradiation amount can be obtained thereby enabling to reduce operator's radiation exposure. (N.H.)

  2. Design and testing of tubular polymeric capsules for self-healing of concrete

    Science.gov (United States)

    Araújo, M.; Van Tittelboom, K.; Feiteira, J.; Gruyaert, E.; Chatrabhuti, S.; Raquez, J.-M.; Šavija, B.; Alderete, N.; Schlangen, E.; De Belie, N.

    2017-10-01

    Polymeric healing agents have proven their efficiency to heal cracks in concrete in an autonomous way. However, the bottleneck for valorisation of self-healing concrete with polymeric healing agents is their encapsulation. In the present work, the suitability of polymeric materials such as poly(methyl methacrylate) (PMMA), polystyrene (PS) and poly(lactic acid) (PLA) as carriers for healing agents in self-healing concrete has been evaluated. The durability of the polymeric capsules in different environments (demineralized water, salt water and simulated concrete pore solution) and their compatibility with various healing agents have been assessed. Next, a numerical model was used to simulate capsule rupture when intersected by a crack in concrete and validated experimentally. Finally, two real-scale self-healing concrete beams were made, containing the selected polymeric capsules (with the best properties regarding resistance to concrete mixing and breakage upon crack formation) or glass capsules and a reference beam without capsules. The self-healing efficiency was determined after crack creation by 3-point-bending tests.

  3. Utility of capsule endoscopy for evaluating anthelmintic efficacy in fully conscious dogs.

    Science.gov (United States)

    Lee, Alice C Y; Epe, Christian; Simpson, Kenneth W; Bowman, Dwight D

    2011-11-01

    The current accepted standard for evaluating the efficacy of gastrointestinal anthelmintic drugs is necropsy of infected animals followed by a comparison of worm counts between treated and non-treated groups. In this study capsule endoscopy, a minimally invasive method of imaging the small intestine of humans, is evaluated as a possible alternative to necropsy for the purposes of worm quantification in dogs. Eighteen Beagle dogs were included in this study. These dogs were part of a separate trial intended to determine the efficacy of various candidate parasiticides against Ancylostoma caninum via the necropsy standard. Dogs were inoculated with A. caninum L3s 4 weeks prior to treatment with one of the candidate compounds; a control group (n=8) received no treatment. Capsule endoscopy was performed 6-14 days post-treatment, followed by necropsy the following day. Seventeen dogs had complete examinations, i.e. the capsule traversed the small intestine and reached the colon within the battery life of the capsule. A strong correlation (r(s)=0.87, Pcapsule endoscopy and necropsy. There was no clear relationship between the ability of the capsule endoscope to detect hookworms and either visibility of the intestinal lumen or small intestinal transit time. Generation of a virtual spatial record of hookworm location from the capsule endoscopy data revealed a temporal trend, with the majority of worms present in the proximal small intestine in the morning versus the central to distal small intestine in the afternoon. Worm distribution as determined by capsule endoscopy closely resembled post-mortem findings. In conclusion, capsule endoscopy shows promise as an alternative to necropsy for the enumeration of A. caninum in the canine small intestine, although further work is required to improve completion rates and optimise intestinal examination. Copyright © 2011 Australian Society for Parasitology Inc. Published by Elsevier Ltd. All rights reserved.

  4. Swallowable Wireless Capsule Endoscopy: Progress and Technical Challenges

    Directory of Open Access Journals (Sweden)

    Guobing Pan

    2012-01-01

    Full Text Available Wireless capsule endoscopy (WCE offers a feasible noninvasive way to detect the whole gastrointestinal (GI tract and revolutionizes the diagnosis technology. However, compared with wired endoscopies, the limited working time, the low frame rate, and the low image resolution limit the wider application. The progress of this new technology is reviewed in this paper, and the evolution tendencies are analyzed to be high image resolution, high frame rate, and long working time. Unfortunately, the power supply of capsule endoscope (CE is the bottleneck. Wireless power transmission (WPT is the promising solution to this problem, but is also the technical challenge. Active CE is another tendency and will be the next geneion of the WCE. Nevertheless, it will not come true shortly, unless the practical locomotion mechanism of the active CE in GI tract is achieved. The locomotion mechanism is the other technical challenge, besides the challenge of WPT. The progress about the WPT and the active capsule technology is reviewed.

  5. Capsule performance optimization in the National Ignition Campaigna)

    Science.gov (United States)

    Landen, O. L.; Boehly, T. R.; Bradley, D. K.; Braun, D. G.; Callahan, D. A.; Celliers, P. M.; Collins, G. W.; Dewald, E. L.; Divol, L.; Glenzer, S. H.; Hamza, A.; Hicks, D. G.; Hoffman, N.; Izumi, N.; Jones, O. S.; Kirkwood, R. K.; Kyrala, G. A.; Michel, P.; Milovich, J.; Munro, D. H.; Nikroo, A.; Olson, R. E.; Robey, H. F.; Spears, B. K.; Thomas, C. A.; Weber, S. V.; Wilson, D. C.; Marinak, M. M.; Suter, L. J.; Hammel, B. A.; Meyerhofer, D. D.; Atherton, J.; Edwards, J.; Haan, S. W.; Lindl, J. D.; MacGowan, B. J.; Moses, E. I.

    2010-05-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [G. H. Miller et al., Nucl. Fusion 44, 228 (2004)] to substantially increase the probability of ignition by laser-driven hohlraums [J. D. Lindl et al., Phys. Plasmas 11, 339 (2004)]. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the OMEGA facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  6. Capsule performance optimization in the National Ignition Campaign

    International Nuclear Information System (INIS)

    Landen, O. L.; Bradley, D. K.; Braun, D. G.; Callahan, D. A.; Celliers, P. M.; Collins, G. W.; Dewald, E. L.; Divol, L.; Glenzer, S. H.; Hamza, A.; Hicks, D. G.; Izumi, N.; Jones, O. S.; Kirkwood, R. K.; Michel, P.; Milovich, J.; Munro, D. H.; Robey, H. F.; Spears, B. K.; Thomas, C. A.

    2010-01-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [G. H. Miller et al., Nucl. Fusion 44, 228 (2004)] to substantially increase the probability of ignition by laser-driven hohlraums [J. D. Lindl et al., Phys. Plasmas 11, 339 (2004)]. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the OMEGA facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  7. Technology Insight: current status of video capsule endoscopy.

    Science.gov (United States)

    Cave, David R

    2006-03-01

    Video capsule endoscopy (VCE) is the most recent major practical and conceptual development in the field of endoscopy. The video capsule endoscope-a small, pill-sized, passive imaging device-has been demonstrated to be the pre-eminent imaging device for disorders of the small intestine. The initial use for VCE was to detect the origin of obscure gastrointestinal bleeding. Several other indications have now been justified, or are in the process of evaluation. More than 200,000 of these disposable devices have been used worldwide, with an extraordinarily good safety record: indeed, the device has been approved for use in children as young as 10 years of age. In addition, a double-ended capsule has now been approved for the evaluation of mucosal disease in the esophagus. The now-widespread deployment of the device into gastrointestinal practice in the US and many other countries suggests that VCE has achieved mainstream utility. The development of similar competitor devices, and devices whose movement can be controlled, is in progress.

  8. Differential expression profiling of circulation microRNAs in PTC patients with non-131I and 131I-avid lungs metastases: a pilot study

    International Nuclear Information System (INIS)

    Qiu, Zhong-Ling; Shen, Chen-Tian; Song, Hong-Jun; Wei, Wei-Jun; Luo, Quan-Yong

    2015-01-01

    Introduction: Loss of the ability to concentrate 131 I is one of the important causes of radioiodine-refractory disease in papillary thyroid carcinoma (PTC). Recent advantages of serum microRNAs (miRNAs) open a new realm of possibilities for noninvasive diagnosis and prognosis of many cancers. The aim of the current study was to identify differential expression profiling of circulation miRNAs in PTC patients with non- 131 I and 131 I-avid lungs metastases. Methods: The expressions of miRNAs were examined using miRNA microarray chip. The most significantly changed miRNAs from microarray were verified by using qRT-PCR. The potential miRNAs regulating target genes and their preliminary biological functions were forecasted by Bioinformatic analysis. Results: Compared to 131 I-avid lung metastases, 13 kinds of significantly differential serum miRNAs including 5 upregulated miRNAs (miR-1249, miR-106a, miR-503, miR-34c-5p, miR-1281) and 8 downregulated miRNAs (miR-1915, miR-2861, miR-3196, miR-500, miR-572, miR-33b, miR-554, miR-18a) in PTC patients with non- 131 I-avid lung metastases were identified. Bioinformatic analysis demonstrated that miR-106a was the core miRNA regulating 193 genes in the network. The results of validation confirmed the up-regulation of miR-106a in non- 131 I-avid lungs metastatic PTC patients. Conclusion: Differentially expressed serum miRNA profiles between PTC patients with non- 131 I and 131 I-avid lungs metastases were analyzed. These findings in our present study could represent new clues for the diagnostic and therapeutic strategy in PTC patients with non- 131 I-avid metastatic disease

  9. Distribution and Bioaccumulation of I-131 Within The Water-Fish System

    International Nuclear Information System (INIS)

    Darussalam, M; Wijaya, DGO; Sutrisno

    1996-01-01

    Distribution and Bioaccumulation of I-131 Within The Water-Fish System. As one of fission products, radioiodine I-131 potentially become a pollutant either resulted froma fallout or radioactive waste. Therefore, special interest has been given to handle I-131 starting from its production implementation and its waste management. The observations in this research have been focussed on distribution and bio accumulation of I-131 within the water-fish systems. Some number of Tilapia fish were put in aquaria containing I-131 contamined water with certain radioactivity concentration. Within time interval of 0, 6, 24, 48 and 72 hours after treatment the radioactivities of water media. fish and their organs have been measured. The results show that the radioactivity percentage different water media containing different I-131 concentration tend to have similar patterns. Meanwhile, the I-131 concentrations of fish and their organs were varied with similar patterns for different I-131 content in water media

  10. Structure and selectivity trends in crystalline urea-functionalized anion-binding capsules

    Energy Technology Data Exchange (ETDEWEB)

    Rajbanshi, Arbin [Oak Ridge National Laboratory (ORNL); Custelcean, Radu [ORNL

    2012-01-01

    A tripodal trisurea receptor (L1) persistently self-assembles with various divalent oxoanion salts M{sub n}X (M = Na, K, Mg, Ca, Cd; X = SO{sub 4}{sup 2-}, SO{sub 3}{sup 2-}, SeO{sub 4}{sup 2-}, CrO{sub 4}{sup 2-}) into isomorphous series of crystalline frameworks in three different compositions: MX(L1){sub 2}(H{sub 2}O){sub 6} (M = Mg, Ca, Cd) (1), Na{sub 2}X(L1){sub 2}(H{sub 2}O){sub 4} (2) and K{sub 2}X(L1){sub 2}(H{sub 2}O){sub 2} (3). Single-crystal X-ray structural analysis revealed that all three series of structures adopt a NaCl-type topology, consisting of alternating anionic X(L1){sub 2}{sup 2-} capsules and M(H{sub 2}O){sub 6}{sup 2+}, Na{sub 2}(H{sub 2}O){sub 4}{sup 2+} or K{sub 2}(H{sub 2}O){sub 2}{sup 2+} hydrated cations. The capsules provide a complementary environment to tetrahedral oxoanions via 12 hydrogen bonds from six urea groups lining the cavities of the capsules. The persistent formation of the capsules facilitated the investigation of structural trends and structure-selectivity relationships across series 1-3. First, it was found that the size of the capsules is relatively unresponsive to the change in the encapsulated anion, resulting in good shape and size recognition in the separation of anions by competitive crystallizations. Second, it was found that the size of the capsules varies linearly with the size of the external cation, which provides a way for tuning the anion encapsulation selectivity. However, no straightforward dependence was found between the size of the capsules and the relative selectivity for different-sized tetrahedral oxoanions in competitive crystallizations.

  11. Assessment of patency capsule retention using MR diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Klang, Eyal; Rozendorn, Noa; Amitai, Michal Marianne [Sheba Medical Center, Department of Diagnostic Imaging, Ramat Gan (Israel); Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Kopylov, Uri; Ben-Horin, Shomron; Lahat, Adi; Yablecovitch, Doron; Eliakim, Rami [Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Sheba Medical Center, Department of Gastroenterology, Ramat Gan (Israel)

    2017-12-15

    Evaluate the ability of MR diffusion-weighted imaging (DWI) to predict patency capsule retention in Crohn's disease (CD). Clinical and imaging data were prospectively reviewed for 80 CD patients following patency capsule administration and MR-DWI under institutional review board (IRB) approval with informed consent. Two radiologists separately assessed the presence/absence of restricted diffusion in the distal ileum. Apparent diffusion coefficients (ADC) from three regions of interest on the ileal wall were averaged. The association between restricted diffusion and retention, and sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. Ability of ADC to predict retention was assessed with receiver operating characteristic (ROC) curve analysis. Restricted diffusion in the distal ileum was associated with capsule retention (p = 0.001, p < 0.0001). Sensitivity, specificity, PPV and NPV of restricted diffusion for capsule retention were 100.0%, 46.2%, 30.0%, 100% and 100.0%, 56.9%, 34.9%, 100%, respectively, for two radiologists. Accuracy of ADC to predict retention was high (area under the curve = 0.851, p < 0.0001). An ADC of 1.47 mm{sup 2}/s showed 90.0% sensitivity and 50.0% specificity for retention. Sensitivity and NPV of restricted diffusion for patency capsule retention were 100%, suggesting that DWI may predict gastrointestinal tract capability to pass video camera endoscopy. (orig.)

  12. Assessment of patency capsule retention using MR diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Klang, Eyal; Rozendorn, Noa; Amitai, Michal Marianne; Kopylov, Uri; Ben-Horin, Shomron; Lahat, Adi; Yablecovitch, Doron; Eliakim, Rami

    2017-01-01

    Evaluate the ability of MR diffusion-weighted imaging (DWI) to predict patency capsule retention in Crohn's disease (CD). Clinical and imaging data were prospectively reviewed for 80 CD patients following patency capsule administration and MR-DWI under institutional review board (IRB) approval with informed consent. Two radiologists separately assessed the presence/absence of restricted diffusion in the distal ileum. Apparent diffusion coefficients (ADC) from three regions of interest on the ileal wall were averaged. The association between restricted diffusion and retention, and sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. Ability of ADC to predict retention was assessed with receiver operating characteristic (ROC) curve analysis. Restricted diffusion in the distal ileum was associated with capsule retention (p = 0.001, p < 0.0001). Sensitivity, specificity, PPV and NPV of restricted diffusion for capsule retention were 100.0%, 46.2%, 30.0%, 100% and 100.0%, 56.9%, 34.9%, 100%, respectively, for two radiologists. Accuracy of ADC to predict retention was high (area under the curve = 0.851, p < 0.0001). An ADC of 1.47 mm 2 /s showed 90.0% sensitivity and 50.0% specificity for retention. Sensitivity and NPV of restricted diffusion for patency capsule retention were 100%, suggesting that DWI may predict gastrointestinal tract capability to pass video camera endoscopy. (orig.)

  13. Development of a design methodology for hydraulic pipelines carrying rectangular capsules

    International Nuclear Information System (INIS)

    Asim, Taimoor; Mishra, Rakesh; Abushaala, Sufyan; Jain, Anuj

    2016-01-01

    The scarcity of fossil fuels is affecting the efficiency of established modes of cargo transport within the transportation industry. Efforts have been made to develop innovative modes of transport that can be adopted for economic and environmental friendly operating systems. Solid material, for instance, can be packed in rectangular containers (commonly known as capsules), which can then be transported in different concentrations very effectively using the fluid energy in pipelines. For economical and efficient design of such systems, both the local flow characteristics and the global performance parameters need to be carefully investigated. Published literature is severely limited in establishing the effects of local flow features on system characteristics of Hydraulic Capsule Pipelines (HCPs). The present study focuses on using a well validated Computational Fluid Dynamics (CFD) tool to numerically simulate the solid-liquid mixture flow in both on-shore and off-shore HCPs applications including bends. Discrete Phase Modelling (DPM) has been employed to calculate the velocity of the rectangular capsules. Numerical predictions have been used to develop novel semi-empirical prediction models for pressure drop in HCPs, which have then been embedded into a robust and user-friendly pipeline optimisation methodology based on Least-Cost Principle. - Highlights: • Local flow characteristics in a pipeline transporting rectangular capsules. • Development of prediction models for the pressure drop contribution of capsules. • Methodology developed for sizing of Hydraulic Capsule Pipelines. • Implementation of the developed methodology to obtain optimal pipeline diameter.

  14. The roles of Tenascin C and Fibronectin 1 in adhesive capsulitis: a pilot gene expression study

    Directory of Open Access Journals (Sweden)

    Carina Cohen

    Full Text Available OBJECTIVES: We evaluated mRNA expression levels of genes that encode TGF-β1; the TGF-β1 receptor; the collagen-modifying enzymes LOX, PLOD1, and PLOD2; and the extracellular matrix proteins COMP, FN1, TNC and TNXB in synovial/capsule specimens from patients with idiopathic adhesive capsulitis. Possible associations between the measured mRNA levels and clinical parameters were also investigated. METHODS: We obtained glenohumeral joint synovium/capsule specimens from 9 patients with idiopathic adhesive capsulitis who had not shown improvement in symptoms after 5 months of physiotherapy. Adhesive capsulitis was confirmed in all patients by magnetic resonance imaging. We also obtained specimens from 8 control patients who had underwent surgery for acute acromioclavicular joint dislocation and who had radiological indication of glenohumeral capsule alteration based on arthroscopic evaluation. mRNA expression in the synovium/capsule specimens was analyzed by quantitative reverse transcription PCR. The B2M and HPRT1 genes were used as references to normalize target gene expression in the shoulder tissue samples. RESULTS: The synovium/capsule samples from the patients with adhesive capsulitis had significantly higher TNC and FN1 expression than those from the controls. Additionally, symptom duration directly correlated with expression of TGFβ1 receptor I. CONCLUSION: Elevated levels of TNC and FN1 expression may be a marker of capsule injury. Upregulation of TGFβ1 receptor I seems to be dependent on symptom duration; therefore, TGFβ signaling may be involved in adhesive capsulitis. As such, TNC, FN1 and TGFβ1 receptor I may also play roles in adhesive capsulitis by contributing to capsule inflammation and fibrosis.

  15. Collapse of experimental capsules under external pressure

    International Nuclear Information System (INIS)

    Simonen, F.A.; Shippell, R.J. Jr.

    1980-01-01

    Stress analyses and developmental tests of capsules fabricated from thick-walled tubing were performed for an external pressure design condition. In the design procedure no credit was taken for the expected margin in pressure between yielding of the capsule wall and catastrophic collapse or flattening. In tests of AISI-1018 low carbon steel capsules, a significant margin was seen between yield and collapse pressure. However, the experimental yield pressures were significantly below predictions, essentially eliminating the safety margin present in the conservative design approach. The differences between predictions and test results are attributed to deficiencies in the plasticity theories commonly in use for engineering stress analyses. The results of this study show that the von Mises yield condition does not accurately describe the yield behavior of the AISI-1018 steel tubing material for the triaxial stress conditions of interest. Finite element stress analyses successfully predicted the transition between uniform inward plastic deformation and ovalization that leads to catastrophic collapse. After adjustments to correct for the unexpected yield behavior of the tube material, the predicted pressure-deflection trends were found to follow the experimental data

  16. The application value of capsule endoscopy in diagnosing small intestinal carcinoma

    Directory of Open Access Journals (Sweden)

    Xiaohuan Li

    2018-01-01

    Conclusion: Capsule endoscopy demonstrated a high diagnostic value for various small bowel diseases, including both tumor and inflammatory lesions. Given its simplicity, safety, and reliability, capsule endoscopy was an important examination tool for the diagnosis of small bowel diseases.

  17. Quality control of 131I treatment of graves' disease

    International Nuclear Information System (INIS)

    Liu Zeng; Liu Guoqiang

    2009-01-01

    To make a preliminary quality control (QC) criteria and apply on the various stages of clinic 131 I treatment of Graves' disease in order to decrease the early happening of hypothyroidism and enhance the onetime 131 I cure rate of Graves' disease, the quality control criteria in the stochastic outpatient with 131 I treatment, such as plan of the indication, contraindication, method of treatment, matters needing attention, follow-up observation and curative effect appraisal, patient selection, RAIU, thyroid gland weight measurement and 131 I dose criteria for the various steps of 131 I medication were determined. The 131 I treatment effects of Graves' disease including the once-cure rate, the improving rate, duplicate cure rate and the early happening rate of hypothyroidism were analyzed in patients with applying QC and without QC ccriteria. The results showed that the oncecure rate in patients with applying QC criteria was increased from 76.6% to 90.9% (P≤0.01); the improving rate was decreased from 12.2% to 7.0% (P≤0.01); the duplicate cure rate was increased from 90.1% to 93.0% (P>0.05); the early happening rate of hypothyroidism was decreased from 11.0% to 2.1% (P≤0.01). The 131 I treatment of Graves' disease applying with QC criteria had tremendously improved the oncecure rate and decreased the early happening of hypothyroidism rate. (authors)

  18. The clinical significance of measuring the thyroid 131I uptake rate to identify the type of premature hypothyroidism for hyperthyroid after 131I treatment

    International Nuclear Information System (INIS)

    Deng Bo; Chen Huaming; Zhu Tianfeng

    2001-01-01

    The 3 h thyroid 131 I uptake rate and the content of serum TT 3 , TT 4 , TSH are measured in 63 patients of premature hypothyroidism (consisting of 33 provisional hypothyroids and 30 perpetual hypothyroidism) before and after thyroxine substitutes treatment for six moths. The results show that there is obvious difference in 131 I uptake rate compared provisional hypothyroidism with perpetual hypothyroidism, and no difference in the content of serum TT 3 , TT 4 , TSH before the treatment. Compared with normal conditions, there is no difference in 131 I uptake rate of provisional hypothyroidism, but the 131 I uptake rate of perpetual hypothyroidism has obvious decrease before and after the treatment. Therefore the type of patients who suffer from premature hypothyroidism can be distinguished according to the 131 I uptake rate: if the 3 h thyroid 131 I uptake rate is normal, it is provisional hypothyroidism; if not, it is perpetual hypothyroidism

  19. Effficacy of 131I therapy hyperthyroidism in adolescent

    International Nuclear Information System (INIS)

    Qin Lan; Wang Junqi; Feng Xuemin; Yin Le

    2004-01-01

    To investigate the possibility of 131 I therapy hyperthyroidism in adolescent, 117 adolescent patients treated with 131 I are analyzed retrospectively. In the first treatment of 131 I, 76 patients gain with euthyroidism (65.0%), 28 patients have remission (23.9%), 13 patients have hypothyroidism (11.0%), the total efficacy is 88.9%. The administered dose to the patients with younger than 14 years is significantly lower than the patients aged from 15 years to 18 years. There is no significantly difference in cure rate or incidence of hypothyroidism between the two groups. The second treatment may improve the cure rate and not exert any significant impact to the incidence of hypothyroidism. Therefore, 131 I treatment hyperthyroidism in younger is efficacious, inexpensive and safe. The dosages given to patients are different between age groups. (authors)

  20. Next generation molten NaI batteries for grid scale energy storage

    Science.gov (United States)

    Small, Leo J.; Eccleston, Alexis; Lamb, Joshua; Read, Andrew C.; Robins, Matthew; Meaders, Thomas; Ingersoll, David; Clem, Paul G.; Bhavaraju, Sai; Spoerke, Erik D.

    2017-08-01

    Robust, safe, and reliable grid-scale energy storage continues to be a priority for improved energy surety, expanded integration of renewable energy, and greater system agility required to meet modern dynamic and evolving electrical energy demands. We describe here a new sodium-based battery based on a molten sodium anode, a sodium iodide/aluminum chloride (NaI/AlCl3) cathode, and a high conductivity NaSICON (Na1+xZr2SixP3-xO12) ceramic separator. This NaI battery operates at intermediate temperatures (120-180 °C) and boasts an energy density of >150 Wh kg-1. The energy-dense NaI-AlCl3 ionic liquid catholyte avoids lifetime-limiting plating and intercalation reactions, and the use of earth-abundant elements minimizes materials costs and eliminates economic uncertainties associated with lithium metal. Moreover, the inherent safety of this system under internal mechanical failure is characterized by negligible heat or gas production and benign reaction products (Al, NaCl). Scalability in design is exemplified through evolution from 0.85 to 10 Ah (28 Wh) form factors, displaying lifetime average Coulombic efficiencies of 99.45% and energy efficiencies of 81.96% over dynamic testing lasting >3000 h. This demonstration promises a safe, cost-effective, and long-lifetime technology as an attractive candidate for grid scale storage.

  1. Colon Cancer Detection by ‘Rendezvous Colonoscopy’: Successful Removal of Stuck Colon Capsule by Conventional Colonoscopy

    Directory of Open Access Journals (Sweden)

    István Rácz

    2010-02-01

    Full Text Available Although capsule retention is a known complication of small bowel capsule endoscopy, initial studies with colon capsule endoscopy (CCE have not reported any capsule retention or sticking neither in the small bowel nor in the colon. We report a complication of CCE when the stuck colon capsule was passed through the malignant colon stricture and removed by the aid of a flexible colonoscope. During CCE in a 76-year-old iron deficiency anemia patient the real-time viewing system indicated the colon capsule to be stuck in a malignant ascending colon stricture for more than two hours. With the aim to avoid complete capsule retention, immediate colonoscopy was performed. The stuck capsule was caught by a polypectomy snare, passed through the tumor stricture and finally removed from the large bowel. The current case describes the usefulness of the real-time viewing system. Similar situations may occur during the forthcoming spread of CCE and the present case is an example of how to manage the potentially risky stuck colon capsule condition.

  2. Applicability of a portable CdTe and NaI (Tl) spectrometer for activity measure; Aplicabilidade de um espectrometro portatil de CdTe e NaI (Tl) para a medida da atividade de Cesio-137 ({sup 137}Cs) e Berilio-7 ({sup 7}Be)

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Jaquiel Salvi

    2005-02-15

    In this work it was studied the application of an in situ gamma spectrometer (ROVER) of Amptek Inc., composed by a Cadmium Telluride detector (CdTe) of 3 mm x 3 mm x 1 mm and a 30 mm x 30 mm Sodium Iodide detector doped with Thallium [NaI (Tl)). The radioactive sources used were type pastille, sealed in aluminum and polyethylene, of {sup 241}Am, {sup 133}Ba, {sup 152}Eu, 3 sources of {sup 137}Cs and soil samples contaminated with {sup 137}Cs. It was performed a factorial planning 2{sup 3} to optimize the in situ spectrometry system. This way it was determined that the best temperature for CdTe crystal operation is -22, deg C, with Shaping Time of 3 {mu}S and Rise Time Discrimination (RTD) with value 3. With the help of the certified radioactive sources, we determined the efficiency curve of the two detectors. The CdTe detector was positioned at the standard distance of 1 meter of the sources and also at 4.15 cm. The NaI (Tl) detector was also positioned at the standard distance of 1 meter of the sources and at 2.8 cm. Measures were performed to determine the Minimum Detectable Activity (MDA) for both detectors. For the pastille type sources, the {sup 137}Cs MDA for the CdTe detector at 4.15 cm, analyzing the energy line of 32 keV, was 6 kBq and at 1 meter of the {sup 137}Cs source, analyzing the line of 661.65 keV, the MDA was 67 kBq. For soil samples, CdTe detector at 4.15 cm presented a MDA of 693 kBq.kg-l for the line of 32 keV, and for the soil sample {sup 7}Be content the MDA found was 2867 Bq.kg{sup -1} at 4.15 cm. For the NaI (Tl) detector, analyzing the line of 661.65 keV, the {sup 137}Cs MDA for pastille type source at 1 meter of distance was 7 kBq, and for soil sample at 2.8 cm the measured {sup 137}Cs MDA was 71 Bq.kg{sup -1}. For the soil sample {sup 7}Be content, at 2.8 cm of the Nal (Tl) detector, the obtained MDA was 91 Bq.kg{sup -1}. Due to the minimum detectable activities found for the two detectors, we concluded that the employed in situ gamma

  3. A Comparative Study of {sup 131}I-Hippuran Renogram, {sup 131}I-Hippuran Urinary Excretion Test and Intravenous Pyelogram in Obstructive Uropathy due to Cancerous Invasion

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kee Bok; Rhee, Chong Heon; Hong, Chang Gi; Park, Soo Seong; Koh, Chang Soon [Radiological Research Institue, Seoul (Korea, Republic of)

    1968-03-15

    A comparative study of {sup 131}I-hippuran renogram, {sup 131}I-hippuran excretion test and intravenous pyelogram were performed in 61 cases of gynecological cancer. The following were the results: 1) Among 40 cases of cervix cancer showing normal excretory urography 7 cases (17.5%) were found to have unilateral or bilateral delayed excretory pattern on {sup 131}I-hippuran renogram and on the contrary only 2 cases (5.7%) showed a mild caliectatic change on excretory urography among 35 cases of gynecological cancer showing normal pattern of {sup 131}I-hippuran renogram. 2) In the group showing unilateral of bilateral delayed excretory pattern of {sup 131}I-hippuran renogram there was a reduction of {sup 131}I-hippuran excretion in the first 20 minutes, but there was no significant difference of {sup 131}I-hippuran excretion in 60 minutes compared with that of normal renogram group. 3) In the group showing unilateral non-functioning pattern of {sup 131}I-hippuran renogram in one side and normal pattern in the other side there was found to be no difference in {sup 131}I-hippuran excretion amount compared with that of normal renogram group. 4) It was evident from these experimental study that {sup 131}I-hippuran renogram was considered as a good examination method for the evaluation of obstructive uropathy, and if one side kidney was intact it might compensate for the other diseased kidney so far as to renal excretory function. It was also shown that the more severe the cancerous spread in the pelvic wall the more changes on {sup 131}I-hippuran renogram.

  4. Iodine 131 and 133 as Fission Indicators

    Energy Technology Data Exchange (ETDEWEB)

    Broda, E.

    1944-07-01

    This report was written by E. Broda at the Cavendish Laboratory (Cambridge) in September 1944 and is about the possible use of Iodine 131 and 133 as fission indicators. Additionally, the description of the chemical procedure for I 131 and I 133 and the corresponding results can be found in this report. (nowak)

  5. Crossed-swords, capsule-pinch technique for capsulotomy in pediatric and/or loose lens cataract extraction.

    Science.gov (United States)

    Snyder, Michael E; Lindsell, Luke B

    2010-02-01

    Puncturing the anterior capsule in a patient with a very soft lens, an elastic capsule, and/or deficient zonular countertraction can be challenging even with a sharp needle or blade. The crossed-swords, capsule-pinch technique capitalizes on opposing forces from 2 needles directed toward each other with a "pinch" of the capsule between their tips. This affords a controlled and facile puncture of the capsule without creating stress on the zonules or anteroposterior displacement of the lens. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. An O antigen capsule modulates bacterial pathogenesis in Shigella sonnei.

    Science.gov (United States)

    Caboni, Mariaelena; Pédron, Thierry; Rossi, Omar; Goulding, David; Pickard, Derek; Citiulo, Francesco; MacLennan, Calman A; Dougan, Gordon; Thomson, Nicholas R; Saul, Allan; Sansonetti, Philippe J; Gerke, Christiane

    2015-03-01

    Shigella is the leading cause for dysentery worldwide. Together with several virulence factors employed for invasion, the presence and length of the O antigen (OAg) of the lipopolysaccharide (LPS) plays a key role in pathogenesis. S. flexneri 2a has a bimodal OAg chain length distribution regulated in a growth-dependent manner, whereas S. sonnei LPS comprises a monomodal OAg. Here we reveal that S. sonnei, but not S. flexneri 2a, possesses a high molecular weight, immunogenic group 4 capsule, characterized by structural similarity to LPS OAg. We found that a galU mutant of S. sonnei, that is unable to produce a complete LPS with OAg attached, can still assemble OAg material on the cell surface, but a galU mutant of S. flexneri 2a cannot. High molecular weight material not linked to the LPS was purified from S. sonnei and confirmed by NMR to contain the specific sugars of the S. sonnei OAg. Deletion of genes homologous to the group 4 capsule synthesis cluster, previously described in Escherichia coli, abolished the generation of the high molecular weight OAg material. This OAg capsule strongly affects the virulence of S. sonnei. Uncapsulated knockout bacteria were highly invasive in vitro and strongly inflammatory in the rabbit intestine. But, the lack of capsule reduced the ability of S. sonnei to resist complement-mediated killing and to spread from the gut to peripheral organs. In contrast, overexpression of the capsule decreased invasiveness in vitro and inflammation in vivo compared to the wild type. In conclusion, the data indicate that in S. sonnei expression of the capsule modulates bacterial pathogenesis resulting in balanced capabilities to invade and persist in the host environment.

  7. An O antigen capsule modulates bacterial pathogenesis in Shigella sonnei.

    Directory of Open Access Journals (Sweden)

    Mariaelena Caboni

    2015-03-01

    Full Text Available Shigella is the leading cause for dysentery worldwide. Together with several virulence factors employed for invasion, the presence and length of the O antigen (OAg of the lipopolysaccharide (LPS plays a key role in pathogenesis. S. flexneri 2a has a bimodal OAg chain length distribution regulated in a growth-dependent manner, whereas S. sonnei LPS comprises a monomodal OAg. Here we reveal that S. sonnei, but not S. flexneri 2a, possesses a high molecular weight, immunogenic group 4 capsule, characterized by structural similarity to LPS OAg. We found that a galU mutant of S. sonnei, that is unable to produce a complete LPS with OAg attached, can still assemble OAg material on the cell surface, but a galU mutant of S. flexneri 2a cannot. High molecular weight material not linked to the LPS was purified from S. sonnei and confirmed by NMR to contain the specific sugars of the S. sonnei OAg. Deletion of genes homologous to the group 4 capsule synthesis cluster, previously described in Escherichia coli, abolished the generation of the high molecular weight OAg material. This OAg capsule strongly affects the virulence of S. sonnei. Uncapsulated knockout bacteria were highly invasive in vitro and strongly inflammatory in the rabbit intestine. But, the lack of capsule reduced the ability of S. sonnei to resist complement-mediated killing and to spread from the gut to peripheral organs. In contrast, overexpression of the capsule decreased invasiveness in vitro and inflammation in vivo compared to the wild type. In conclusion, the data indicate that in S. sonnei expression of the capsule modulates bacterial pathogenesis resulting in balanced capabilities to invade and persist in the host environment.

  8. Association of quality of sleep with cognitive decline among the patients of chronic kidney disease undergoing haemodialysis

    International Nuclear Information System (INIS)

    Zubair, U.B.; Butt, B.

    2017-01-01

    This study was conducted to determine the association between the subjective quality of sleep and cognitive decline among the patients of chronic kidney disease (CKD) undergoing haemodialysis. Methods: In this cross-sectional study 106 patients of chronic kidney disease (CKD) undergoing haemodialysis at a tertiary care hospital in Rawalpindi, Pakistan were included in the final analysis. Cognitive decline was measured by British Columbia Cognitive Complaints Inventory (BC-CCI). Sleep quality was measured by using the Pittsburgh Sleep Quality Index (PSQI). Relationship of age, gender, marital status, education, occupation, BMI, duration of dialysis, dialysis count per week, family income, tobacco smoking and use of naswar was assessed with the cognitive decline. Results: Out of 106 patients screened through BC-CCI and PSQI, 13.1% had no cognitive decline while 86.9% had significant cognitive decline. Relationship between quality of sleep and cognitive decline was significant on binary logistic regression. Conclusion: This study showed significant relationship between the sleep quality and cognitive decline among the patients of CKD undergoing haemodialysis. The findings of our study also call for a greater degree of understanding of the physical and psychological state of patients of CKD undergoing haemodialysis. (author)

  9. H2 gas pressure calculation of FPM capsule failure at RSG-GAS reactor core

    International Nuclear Information System (INIS)

    Hastuti, Endiah Puji; Sunaryo, Geni Rina

    2002-01-01

    RSG-GAS has been irradiated FPM capsule for 236 times, one of those i.e. capsule number 228 has failure. The one of root cause of failure possibility is radiolysis reaction can be occurred in FPM capsule when it is filled with water during irradiation in the reactor core. The safety analysis of the radiolysis reaction in the capsule has been done. The oc cumulative hydrogen gas production can cause high pressure in the capsule then a mechanical damage occurred. The analysis was done at 10 MW of reactor power which equivalent with neutron flux of 0,6929 x 10 1 4 n/cm 2 sec and γ dose rate of 0,63x10 9 rad/hour. The assumption is the capsule is filled with water at maximum volume, i.e. 176.67 ml. The results of calculation showed that radiolysis reaction with γ and neutron produce hydrogen gas for nominal flow rate each are 494 atm and 19683 atm for γ and neutron radiolysis, respectively. H 2 gas pressure for 5% flow rate each are 723 atm. and 25772 atm., for γ and neutron radiolysis, respectively. The changing of the operation condition due to radiolysis together with one way valve' phenomena, can be produce hydrogen gas from water during irradiation in the reactor core and can be the one of root cause of capsule failure. This analysis recommended the FPM capsule preparation must be guaranteed no water or/and there is no possibility of water immersion in the capsule during irradiation in the core by more accurate leak test

  10. Determination of {sup 131}I and thorium in urine; Determinacao de iodo-131 e torio em urina

    Energy Technology Data Exchange (ETDEWEB)

    Tomida, Rute Miwa

    1978-07-01

    Methods for the determination of {sup 131}I and Thorium in urine have been developed taking into account the monitoring needs for people who handle with these radioisotopes. The method for determining {sup 131}I is based in the use of silver chloride to separate iodine by precipitation from the sample; the detection was carried out in a Nal (Tl) well type scintillator connected to a single channel analyser. This method has the following advantages; it is easy and relatively fast as well as selective, showing a separation yield higher than 80%. Thorium in urine was determined by colorimetry after the mineralization of the sample using nitric acid, and sulphuric acid, and then oxygen peroxide. The chromophore reagent used was Thoron (disodium salt of 2-(2-hydroxy-3,6-disulfo-l-naphthylazo) benzenearsonic acid).The absorbance was measured in a spectro colorimeter at a fixed wavelength (530 nm). The method proved to be simple allowing a separation yield of about 80%. The most representative sample for a monitoring program in a {sup 131}I production laboratory has been established. The {sup 131}I concentration in urine of individuals with chronic contamination have also been measured; an interpretation of these results is discussed. (author)

  11. Ignition capsules with aerogel-supported liquid DT fuel for the National Ignition Facility

    Directory of Open Access Journals (Sweden)

    Ho D.D.-M.

    2013-11-01

    Full Text Available For high repetition-rate fusion power plant applications, capsules with aerogel-supported liquid DT fuel can have much reduced fill time compared to β-layering a solid DT fuel layer. The melting point of liquid DT can be lowered once liquid DT is embedded in an aerogel matrix, and the DT vapor density is consequently closer to the desired density for optimal capsule design requirement. We present design for NIF-scale aerogel-filled capsules based on 1-D and 2-D simulations. An optimal configuration is obtained when the outer radius is increased until the clean fuel fraction is within 65 – 75% at peak velocity. A scan (in ablator and fuel thickness parameter space is used to optimize the capsule configurations. The optimized aerogel-filled capsule has good low-mode robustness and acceptable high-mode mix.

  12. Evaluation of capsule endoscopy to detect mucosal lesions associated with gastrointestinal bleeding in dogs.

    Science.gov (United States)

    Davignon, D L; Lee, A C Y; Johnston, A N; Bowman, D D; Simpson, K W

    2016-03-01

    The objective of this study was to examine the utility of capsule endoscopy to detect mucosal abnormalities in dogs with gastrointestinal haemorrhage. Capsules were administered to 2 healthy controls and 8 patients with gastrointestinal haemorrhage. Images were evaluated for quality, gastric emptying time, small intestinal transit time and presence of lesions. There were no adverse effects of capsule endoscopy in dogs weighing from 7·7 to 58 kg. The capsule traversed the entire gastrointestinal tract in 5 of 8 patients, with high quality images obtained in the stomach and small intestine. Gastric emptying time and small intestinal transit time ranged from 1 to 270 and 15 to 180 minutes, respectively. In 3 of 8 patients, the capsule remained in the stomach despite pro-kinetics. Gastric lesions included mild haemorrhage and pinpoint erosion (4 of 8), a mass (1) and thickened bleeding pyloric mucosa (2). Two of 3 dogs with capsule retention had gastric lesions. Intestinal lesions included a healing duodenal ulcer, abnormal villi, ileal ulceration and colonic bleeding. Lesions identified by capsule endoscopy were considered a significant source of haemorrhage in 4 of 7 dogs with active bleeding. The relevance of pinpoint gastric mucosal erosions to blood loss is unclear. Capsule endoscopy can enable the non-invasive detection of gastric and small intestinal mucosal lesions in dogs presenting for evaluation of gastrointestinal bleeding. © 2016 British Small Animal Veterinary Association.

  13. Labelling of tung oil with 131I

    International Nuclear Information System (INIS)

    Correia, R.J.; Mitta, A.E.A.

    1975-01-01

    A method for labelling Tung Oil with 131 I is described. The oil is dissolved in peroxide free, dry ethyl ether and then it is treated with 131 ICl. A 2,5% mercuric acetate solution in glacial acetic acid is added as a catalist. A radiochemical yield of 100% is achieved in 20 minutes. (author)

  14. Effects of compound amino acids capsule on the immunological function of naval servicemen

    Directory of Open Access Journals (Sweden)

    Hai-zhong ZHONG

    2012-01-01

    Full Text Available Objective  To investigate the effects of the compound amino acids capsule on the immunological function of the naval servicemen during military activity. Methods  The subjects included 100 officers and soldiers, whose Modified Fatigue Rating Scale (MFIS scores were >21 points. The participants were randomly divided into two groups, namely, the amino acids capsule group and placebo group (n=50. Under the condition of military operations, either amino acids capsule (8 kinds of essential amino acids and 11 kinds of vitamins were contained or placebo capsule was given for 14 days continuously. The humoral immune indices, i.e., IgG, IgA, IgM, and complements C3 and C4, were measured with immunoturbidimetry. The percentage of peripheral blood CD subsets was measured using flow cytometry on the first day and 14th day. Results  The levels of IgG, IgM, and complement C3 in the capsule group were significantly higher on the 14th day than on the first day (P+CD4+ T lymphocytes and CD3-CD19+ B lymphocytes in the capsule group on the 14th day were higher than those on the first day, whereas the CD3-CD56+ NK lymphocytes decreased significantly (PConclusion  Compound amino acids capsule can improve the humoral and cellular immunological function of naval servicemen.

  15. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants

    International Nuclear Information System (INIS)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R.

    2007-01-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  16. Capsules with evolving brittleness to resist the preparation of self-healing concrete

    Directory of Open Access Journals (Sweden)

    Gruyaert, E.

    2016-09-01

    Full Text Available Capsules for self-healing concrete have to possess multifunctional properties and it would be an enormous advantage in the valorization process when they could also be mixed in. Therefore, we aimed to develop capsules with evolving brittleness. Capsules with high initial flexibility were prepared by adding a plasticizer to an ethyl cellulose matrix. During hardening of the concrete, the plasticizing agent should leach out to the moist environment yielding more brittle capsules which break upon crack appearance. The tested capsules could easily be mixed in during concrete production. However, incompatibility issues between the capsule wall and the inner polymeric healing agent appeared. Moreover, the capsules became insufficiently brittle and the bond strength to the cementitious matrix was too weak. Consequently, multilayer capsules were tested. These capsules had a high impact resistance to endure concrete mixing and were able to break upon crack formation.Las cápsulas para la auto-reparación del hormigón tienen que poseer propiedades multifuncionales. Una enorme ventaja en el proceso para su valorización se obtendría si aquellas pudieran resistir con éxito el mezclado. Por lo tanto, nos propusimos desarrollar cápsulas cuya fragilidad evoluciona. Cápsulas con una alta flexibilidad inicial se prepararon mediante la adición de un plastificante a una matriz de etil celulosa. Durante el endurecimiento del hormigón, el agente plastificante debe filtrarse hacia el medio ambiente húmedo produciendo cápsulas más frágiles que se rompen con el surgimiento de fisuras. Las cápsulas pudieron ser fácilmente mezcladas durante la producción de hormigón. Sin embargo, aparecieron problemas de incompatibilidad entre la pared de la cápsula y el agente de curación polimérico interior. Por otra parte, las cápsulas se comportaron insuficientemente frágiles y con una baja adherencia hacia la matriz cementicia. En consecuencia, se probaron las c

  17. Radiological Risk for Patients Treated with 131I

    International Nuclear Information System (INIS)

    Chas, J.; Janiak, M.K.; Kowalczyk, A.; Siekierzynski, M.; Dziuk, E.

    2001-01-01

    Full text: Dose equivalents were measured during the three-day therapy with 131 I in patients treated at the Clinic of Endocrinology and Radioisotope Therapy, Central Clinical Hospital, Military University School of Medicine, Warsaw, Poland, for thyroid cancer (supplementary treatment; 21 cases), hyperthyroidism in the Graves-Basedov's disease (18 cases), and toxic nodular goiter (19 cases). The absorbed doses were measured with thermoluminescent dosimeters placed above the jugular incisure and above the pubic symphysis; the readings were used for calculation of the dose equivalent over the thyroid and in the ovaries. Following the radical treatment of thyroid cancer iodine uptake in the thyroid gland was very low and most of the applied 131 I was excreted within one to three days. In our 21 patients who were given on average 2.8 GBq (76 mCi) 131 I and stimulated with TSH (approx. 60 μIU/mL) the mean dose equivalents over the thyroid and in the ovaries were 115±123 mSv and 56±19 mSv, respectively. In comparison, the calculated dose equivalents in the Graves-Basedov's disease patients (424 MBq mean activity of the applied 131 I) and the goiter patients (544 MBq mean activity of the applied 131 I) were approx. 3.5 times higher over the thyroid and approx. 2.5 times lower in the ovaries. No disfunctions of the ovaries were detected in the treated young women. Based on these results it is recommended to stimulate diuresis during the first two-three days after the injection of 131 I. The results also indicate that exposure to ionising radiation of patients treated for various thyroid disorders with 131 I does not lead to the development of clinically detectable non-stochastic effects. (author)

  18. Testicular effects of 131radioiodine therapy for hyperthyroidism

    International Nuclear Information System (INIS)

    Ceccarelli, Claudia; Canale, Domenico; Carolina, Caglieresi; Moschini, Cecilia; Grasso, Lucia; Pinchera, Aldo; Vitti, Paolo

    2005-01-01

    Full text: Little data is available on possible untoward effects of 131 I therapy for hyperthyroidism on gonad male function. FSH, LH, Total Testosterone(T), Inhibin B and spermiogram were evaluated in 15 hyperthyroid males (mean age 38.5+/-6.7 years, m +/- SD) before, and at day 45, month 3, 6 and 12 after 131 I therapy. Mean basal FSH was 5.6 +/- 3.8 mU/ml. After 131 I, FSH remained unchanged in 13 patients. In two, one of whom with basal FSH in the upper normal limits (16.4 mU/ml), a mild increase was observed after therapy. Basal LH and T were in normal range and did not vary significantly after 131 I, but T/LH ratio significantly decreased at month 3 and 6 (basal: 1.34 +/- 0.6; month 3: 0.85 +/- 0.3, p=0.02, month 6: 0.8 +/- 0.1, p= 0.06). Basal Inhibin B values did not vary significantly after 131 I. Basal mean sperm concentration did not differ from that found in a control group of 20 normal men (51.0 +/- 6.9 x 106 E/ml, vs. 57.6 +/- 7.5 x 106 E/ml) and did not vary significantly after 131 I therapy. Sperm progressive motility (SPM) was 39.1+/-4.7 % in hyperthyroid patients and 54.4 +/- 1.8 % in the controls (p=0.02). Ten patients (67%) were asthenospermic (SPM 131 I treatment of hyperthyroidism may account for a marginal and transient damage of Leydig cells, as highlighted by T/LH ratio. The lower SPM and increased theratospermia observed in patients before treatment could be due to hyperthyroidism per se, as suggested by the normalization of SPM in 5/10 patients after therapy. (author)

  19. Welding iridium heat-source capsules for space missions

    International Nuclear Information System (INIS)

    Kanne, W.R. Jr.

    1982-03-01

    A remote computer-controlled welding station was developed to encapsulate radioactive PuO 2 in iridium. Weld quench cracking caused an interruption in production of capsules for upcoming space missions. Hot crack sensitivity of the DOP-26 iridium alloy was associated with low melting constituents in the grain boundaries. The extent of cracking was reduced but could not be eliminated by changes to the welding operation. An ultrasonic test was developed to detect underbead cracks exceeding a threshold size. Production was continued using the ultrasonic test to reject capsules with detectable cracks

  20. Capsule of parotid gland tumor: evaluation by 3.0 T magnetic resonance imaging using surface coils

    International Nuclear Information System (INIS)

    Ishibashi, Mana; Fujii, Shinya; Nishihara, Keisuke; Matsusue, Eiji; Kodani, Kazuhiko; Kaminou, Toshio; Ogawa, Toshihide; Kawamoto, Katsuyuki

    2010-01-01

    Background: Magnetic resonance (MR) imaging of parotid gland tumors has been widely reported, although few reports have evaluated the capsule of parotid gland tumors in detail. Purpose: To evaluate the diagnostic usefulness of 3.0 T MR imaging with surface coils for detection of the parotid gland tumor capsule, and to clarify the characteristics of the capsules. Material and Methods: Seventy-eight patients with parotid gland tumors (63 benign and 15 malignant) were evaluated. Axial and coronal T2-weighted and contrast-enhanced T1-weighted images were obtained using a 3.0 T MR scanner with 70 mm surface coils. It was retrospectively assessed whether each parotid gland tumor was completely surrounded by a capsule. The capsule was classified as regular or irregular in terms of capsular thickness, and as none, mildly, or strongly enhancing in terms of contrast enhancement. Visual interpretations were compared with histopathological findings to evaluate the diagnostic ability of MR imaging to detect parotid gland tumor capsules. Statistical evaluation was conducted concerning the presence of capsules, capsular irregularity, and the difference in contrast enhancement between benign and malignant tumors, and that between pleomorphic adenomas and Warthin's tumors. Results: Capsules completely surrounding the tumor on MR imaging yielded a sensitivity of 87.7% (50/57), specificity of 90.5% (19/21), and accuracy of 88.5% (69/78). Benign tumors had a capsule completely surrounding the tumor significantly more often than malignant tumors (P = 0.009). Concerning capsular irregularity, malignant tumors tended to have more irregular capsules than benign tumors, although there were no significant differences. The capsules of malignant tumors enhanced significantly more strongly than those of benign tumors (P = 0.018). Conclusion: 3.0 T MR imaging using surface coils could correctly depict parotid gland tumor capsules in most cases. Most benign and some malignant tumors had capsules

  1. Effect of 131I therapy on outcomes of Graves' ophthalmopathy

    International Nuclear Information System (INIS)

    Wang Renfei; Tan Jian; Zhang Guizhi; Yin Liang

    2011-01-01

    Objective: To analyze the correlation between the therapeutic effect of Graves' hyperthyroidism and the outcomes of Graves' ophthalmopathy after 131 I therapy, and to explore the effect of 131 I treatment on turnout of Graves' ophthalmopathy. Methods: Six hundreds and fifty-two patients of Graves' disease accompanied with Graves' ophthalmopathy, received one-time 131 I treatment according to routine procedure. We recorded exophthalmometer readings, the signs and symptoms of eyes before therapy. Regular follow-up and appraisal of curative effect were carried out. Results: At least six months after 131 I therapy, the effective rate of Graves' hyperthyroidism and Graves' ophthalmopathy were 94.3% and 73.3% respectively. The total effective rate of hyperthyroidism with ophthalmopathy was 71.2%. There was a significant correlation between the prognosis of Graves' ophthalmopathy and therapeutic efficacy of hyperthyroidism (r=0.302, P 131 I therapy (χ 2 =0.296, P>0.05). Conclusions: The key to treat Graves' ophthalmopathy is the cure of Graves' hyperthyroidism through 131 I therapy. The timely diagnosis and replacement treatment of hypothyroidism can effectively avoid the aggravation of Graves' ophthalmopathy after 131 I therapy. (authors)

  2. 21 CFR 155.131 - Canned field corn.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Canned field corn. 155.131 Section 155.131 Food... Canned field corn. (a) Identity. (1) Canned field corn conforms to the definition and standard of... corn by § 155.130(a), except that the corn ingredient consists of succulent field corn or a mixture of...

  3. 12 CFR 410.131-410.139 - [Reserved

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false [Reserved] 410.131-410.139 Section 410.131-410.139 Banks and Banking EXPORT-IMPORT BANK OF THE UNITED STATES ENFORCEMENT OF NONDISCRIMINATION ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES CONDUCTED BY EXPORT-IMPORT BANK OF THE UNITED STATES §§ 410...

  4. Fabrication of mechanical system of the FPM capsule puller

    International Nuclear Information System (INIS)

    Sudirdjo, Hari; Prasetya, Hendra

    2000-01-01

    A mechanical system of the FPM capsule puller has been fabricated, which has a function to pull the irradiated FPM capsule. The construction of the system consist of driving motor equipped with reduction gear, spindle, and puller wire. The system has puller stroke of 700 mm, therefore the puller will be terminated at the outside of the reactor core. A function test had been done and shows that the system has fulfilled the requirements

  5. Neuro-fuzzy Classification System for Wireless-Capsule Endoscopic Images

    OpenAIRE

    Vassilis S. Kodogiannis; John N. Lygouras

    2008-01-01

    In this research study, an intelligent detection system to support medical diagnosis and detection of abnormal lesions by processing endoscopic images is presented. The images used in this study have been obtained using the M2A Swallowable Imaging Capsule - a patented, video color-imaging disposable capsule. Schemes have been developed to extract texture features from the fuzzy texture spectra in the chromatic and achromatic domains for a selected region of interest from ...

  6. Radioiodine 131I metabolism in human

    International Nuclear Information System (INIS)

    Mori, Toru

    1976-01-01

    Metabolic fate of orally administered 131 I in human was studied. Chronological observations of whole body radioactivity distribution and thyroid 131 I uptake curve revealed that 131 I metabolism was greatly affected by the amount of dietary iodine intake. Under the high iodine intake exceeding 1 mg per day, uptake curve showed biphasic descending type, that is, rapid accumulation during 3 to 6 hours and rapid fall up to 48 hours and gradual decrease afterwards. While, ascending type, monophasic and maximal at 24 hours, was found universary under low iodine intake less than 500 μg per day. Thyroid function should not be affected by the amount of iodine intake, and we analysed 131 I metabolism using a new four compartments which included intrathyroidal inorganic iodine pool. The results, especially hormone production rate, were found quite useful even under high iodine intake. Thyroidal organic iodine contents were calculated as approximately 2.5 mg and this value was much less than previously reported values from other countries. Administered radioiodine were mixed up with stable body iodine and reached equilibration by around 10 days. From seroimmunological, histological (microscopic and electron microscopic) studies, and irradiation studies to the cultured human thyroid cells, we concluded that this unexpected phenomenon was derived from chromosomal damage which induced gradual decrease in cell population because of inability to reproduce. Carcinogenic and genetic effects were not serious, and only three leukemic patients were reported in this country and 484 normal babies were born from 7,500 treated parents. Thus, therapeutic dose of 131 I was proved rather safe, and even when exposed to radioiodine, administration of perchlorate or thiocyanate, excessive iodine and TSH seemed effective to avoid radiation injuries. (auth.)

  7. A modular and programmable development platform for capsule endoscopy system.

    Science.gov (United States)

    Khan, Tareq Hasan; Shrestha, Ravi; Wahid, Khan A

    2014-06-01

    The state-of-the-art capsule endoscopy (CE) technology offers painless examination for the patients and the ability to examine the interior of the gastrointestinal tract by a noninvasive procedure for the gastroenterologists. In this work, a modular and flexible CE development system platform consisting of a miniature field programmable gate array (FPGA) based electronic capsule, a microcontroller based portable data recorder unit and computer software is designed and developed. Due to the flexible and reprogrammable nature of the system, various image processing and compression algorithms can be tested in the design without requiring any hardware change. The designed capsule prototype supports various imaging modes including white light imaging (WLI) and narrow band imaging (NBI), and communicates with the data recorder in full duplex fashion, which enables configuring the image size and imaging mode in real time during examination. A low complexity image compressor based on a novel color-space is implemented inside the capsule to reduce the amount of RF transmission data. The data recorder contains graphical LCD for real time image viewing and SD cards for storing image data. Data can be uploaded to a computer or Smartphone by SD card, USB interface or by wireless Bluetooth link. Computer software is developed that decompresses and reconstructs images. The fabricated capsule PCBs have a diameter of 16 mm. An ex-vivo animal testing has also been conducted to validate the results.

  8. Effects of lipophilic components on the compatibility of lipid-based formulations with hard gelatin capsules.

    Science.gov (United States)

    Chen, Feng-Jing; Etzler, Frank M; Ubben, Johanna; Birch, Amy; Zhong, Li; Schwabe, Robert; Dudhedia, Mayur S

    2010-01-01

    The present study investigated the effect of lipophilic components on the compatibility of propylene glycol (PG)-containing lipid-based drug delivery system (LBDDS) formulations with hard gelatin capsules. The presence of a lipophilic active pharmaceutical ingredient (API) (log P approximately 6.1) and an additional lipophilic excipient (Capmul MCM) significantly affected the activity of PG in the fills and the equilibrium of PG between capsule shells and fills. These changes in activity and equilibrium of PG were furthermore correlated to the mechanical and thermal properties of the liquid-filled capsules and subsequently linked to the shelf-life of the capsules on stability with respect to capsule deformation. The present study also investigated the mechanism by which lipophilic component(s) might affect the activity of PG in the fill formulations and the equilibrium of PG between capsule shells and fills. The activities of PG in two series of "binary" mixtures with Capmul MCM and with Cremophor EL were measured, respectively. The mixtures of PG containing Capmul MCM were found to be more nearly ideal than those containing Cremophor EL. The observed negative deviation from Rauolt's law indicates that the excess free energies of mixing are less then zero indicating favorable interaction between PG and the other component. It is speculated that enhanced hydrogen bonding opportunities with Cremophor EL are responsible for the decreased excess free energy of mixing. Replacement of Cremophor EL with lipophilic API also reduces the hydrogen bonding opportunities for PG in the mixtures. This hypothesis may further explain the increased activity of PG in the fills and the shifted equilibrium of PG toward the capsule shells. Activity determination utilizing headspace gas chromatography (GC) using short 30 min incubation time seems to be a time-efficient approach for assessing capsule-fill compatibility. Direct measurements of PG migration and other physical properties of

  9. Studies on the radiation burden using I-131 for thyroid therapy

    International Nuclear Information System (INIS)

    Krzesniak, J.W.; Chomicki, O.A.

    1980-01-01

    The exposure to personnel from 131 I inhaled from open sources during laboratory procedures and that exhaled by patients treated with 131 I was estimated. The method and the apparatus used to detect airborne 131 I are described. It was found that the ratio of the activity absorbed through the lungs to that permissible for a given category of exposure is not higher than 10%. The kinetics of the 131 I exhaled by patients seems to be complementary to that of 131 I concentration changes in the blood. (H.K.)

  10. Simulation-Aided Design of Tubular Polymeric Capsules for Self-Healing Concrete

    Science.gov (United States)

    Šavija, Branko; Feiteira, João; Araújo, Maria; Chatrabhuti, Sutima; Raquez, Jean-Marie; Van Tittelboom, Kim; Gruyaert, Elke; De Belie, Nele; Schlangen, Erik

    2016-01-01

    Polymeric capsules can have an advantage over glass capsules used up to now as proof-of-concept carriers in self-healing concrete. They allow easier processing and afford the possibility to fine tune their mechanical properties. Out of the multiple requirements for capsules used in this context, the capability of rupturing when crossed by a crack in concrete of a typical size is one of the most relevant, as without it no healing agent is released into the crack. This study assessed the fitness of five types of polymeric capsules to fulfill this requirement by using a numerical model to screen the best performing ones and verifying their fitness with experimental methods. Capsules made of a specific type of poly(methyl methacrylate) (PMMA) were considered fit for the intended application, rupturing at average crack sizes of 69 and 128 μm, respectively for a wall thickness of ~0.3 and ~0.7 mm. Thicker walls were considered unfit, as they ruptured for crack sizes much higher than 100 μm. Other types of PMMA used and polylactic acid were equally unfit for the same reason. There was overall good fitting between model output and experimental results and an elongation at break of 1.5% is recommended regarding polymers for this application. PMID:28772370

  11. Renal capsule for augmentation cystoplasty in canine model: a favorable biomaterial?

    Directory of Open Access Journals (Sweden)

    Mehdi Salehipour

    2016-04-01

    Full Text Available ABSTRACT Purpose: To evaluate effectiveness of canine renal capsule for augmentation cystoplasty. Materials and Methods: Ten adult dogs participated in this study. After induction of anesthesia each animal underwent bed side urodynamic study, bladder capacity and bladder pressure was recorded. Then via mid line incision abdominal cavity was entered, right kidney was identified and its capsule was dissected. Bladder augmentation was done by anastomosing the renal capsule to the bladder. After 6 months bed side urodynamic study was performed again and changes in bladder volume and pressure were recorded. Then the animals were sacrificed and the augmented bladders were sent for histopathology evaluation. Results: Mean maximum anatomic bladder capacity before cystoplasty was 334.00±11.40cc which increased to 488.00±14.83cc post-operatively (p=0.039. Mean anatomic bladder pressure before cystoplasty was 19.00±1.58cmH2O which decreased to 12.60±1.14cmH2O post-operatively (p=0.039. Histopathology evaluation revealed epithelialization of the renal capsule with urothelium without evidence of fibrosis, collagen deposits or contracture. Conclusions: Our data shows that renal capsule is a favorable biomaterial for bladder augmentation in a canine model.

  12. Vibration test report on the instrumented capsule for fuel irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Yoon, D. B.; Wu, J. S.; Oh, J. M.; Park, S. J.; Cho, M. S.; Kim, B. G.; Kang, Y. W

    2003-01-01

    The fluid-induced vibration level of instrumented capsule, which was manufactured for fuel irradiation test at the reactor core of HANARO, was investigated. For this purpose, the instrumented capsule was loaded at the OR site of the HANARO design verification test facility that could simulate identical flow condition as the HANARO core. Then, vibration signals of the instrumented capsule subjected to various flow conditions were measured by using vibration sensors. In time domain analysis, maximum amplitudes and RMS values of the measured acceleration and displacement signals were obtained. By using frequency domain analysis, frequency components of the fluid-induced vibration were analyzed. In addition, natural frequencies of the instrumented capsule were obtained by performing modal test. The frequency analysis results showed that the natural frequency components near 7.5Hz and 17.5Hz were dominant in the fluid-induced vibration signal. The maximum amplitude of the accelerations was measured as 12.04m/s{sup 2} that is within the allowable vibrational limit(18.99m/s{sup 2})of the reactor structure. Also, the maximum displacement amplitude was calculated as 0.191mm. Since these vibration levels are remarkably low, excessive vibration is not expected when the irradiation test of the instrumented capsule is performed at the HANARO core.

  13. Therapy of hyperthyroidism with Na131I

    International Nuclear Information System (INIS)

    Kakehi, Hirotake; Furukawa, Takashi; Fukakusa, Shunichi; Futonaka, Hiroshi; Takahashi, Yuji

    1984-01-01

    Forty one patients of hyperthyroidism were treated with Na 131 I. Men and women are in the ratio 1:3.1. The ages of patients are between twenties and sixties and the forties are the highest in number. The observation period of clinical courses is between 1 and 8 years. The number of patients observed over 5 years are 51% of them and over 2 years are 83%. The treatment frequency is as follows: On 37 cases each one was treated once with Na 131 I. 2 cases twice, 1 case at 4 times in 3 years and 1 case at 5 times in 6 years. The treatment doses are between 4,000-6,000 rad (40-60 Gray). In the cases treated with the irradiation dose of 6,000 rad, we often saw hypothyroidism. In cases aiming 4,000-5,000 rad, there is a tendency of leaving hyperthyroidism unrecovered. In conclusion, the patients should be treated giving 4,000-5,000 rad or with Na 131 I doses of 3-6mCi. If the effects of the treatment are insufficient, the patients should be further treated with anti-thyroid drug or treated again with Na 131 I. As the result, there are at present 25 cases (61.0%) in normal status of the thyroid gland, 12 cases (29.2%) in hyperthyroidism and 4 cases (9.8%) in hypothyroidism totaling 41 cases in all. (author)

  14. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... When radiotracer is taken by mouth, in either liquid or capsule form, it is typically swallowed up ... radioactive iodine (I-123 or I-131) in liquid or capsule form to swallow. The thyroid uptake ...

  15. Normal and abnormal distribution of the adrenomedullary imaging agent m-[I-131]iodobenzylguanidine (I-131 MIBG) in man; evaluation by scintigraphy

    International Nuclear Information System (INIS)

    Nakajo, M.; Shapiro, B.; Copp, J.; Kalff, V.; Gross, M.D.; Sisson, J.C.; Beierwaltes, W.H.

    1983-01-01

    The scintigraphic distribution of m-[ 131 I]iodobenzylguanidine (I-131 MIBG), an adrenal medullary imaging agent, was studied to determine the patterns of uptake of this agent in man. The normal distribution of I-131 MIBG includes clear portrayal of the salivary glands, liver, spleen, and urinary bladder. The heart, middle and lower lung zones, and colon were less frequently or less clearly seen. The upper lung zones and kidneys were seldom visualized. The thyroid appeared only in cases of inadequate thyroidal blockade. The normal adrenal glands were seldom seen and faintly imaged in 2% at 24 h after injection and in 16% at 48 h, in patients shown not to have pheochromocytomas, whereas intra-adrenal, extra-adrenal, and malignant pheochromocytomas usually appeared as intense focal areas of I-131 MIBG uptake at 24 through 72 h

  16. {sup 131}I treatment of nodular non-toxic goitre

    Energy Technology Data Exchange (ETDEWEB)

    Nygaard, B.; Faber, J.; Hegdeues, L.; Hansen, J.M. [Herlev Hospital (Denmark)

    1996-01-01

    The traditional treatment of a growing nodular non-toxic goitre has for many years been surgical resection or levothyroxine suppressive treatment. During recent years, several studies have reported promising results of {sup 131}I treatment in terms of thyroid size reduction. This review outlines the different treatment modalities on non-toxic nodular goitre with special emphasis on {sup 131}I treatment. By the term nodular goitre the authors include glands with solitary or multiple thyroid nodules with uptake on a scintiscan. At what point of the natural history of non-toxic multinodular goitre {sup 131}I therapy should be used is not clear. In principle, the best result is obtained in smaller goitres and it is possible that the best effect of {sup 131}I is seen if treatment is given to patients with diffuse goitre before these become nodular. However, then there is a potential risk to swing in the direction to where {sup 131}I is used in an indiscriminate way, since the prevalence of non-toxic multinodular goitre is much higher than that of hyperthyroidism. Although we have data on the long-term hazards of {sup 131}I treatment in hyperthyroidism in terms of risk of cancer, we have only follow-up periods of 5 to 10 years for non-toxic goitres in small groups of patients and no data regarding the long-term risk of high-dose {sup 131}I treatment (>600 MBq) for this condition. Ideally, long term randomized studies comparing the effect, side effect and cost-benefit of surgery as opposed to {sup 131}I treatment should be performed. Awaiting this, it is at present mandatory that each individual patient be given a choice of treatment after proper information. 44 refs.

  17. Surface phonon modes of the NaI(001) crystal surface by inelastic He atom scattering

    International Nuclear Information System (INIS)

    Brug, W.P.; Chern, G.; Duan, J.; Safron, S.A.; Skofronick, J.G.; Benedek, G.

    1990-01-01

    The present theoretical treatment of the surface dynamics of ionic insulators employs the shell model with parameters obtained from bulk materials. The approach has been generally very successful in comparisons with experiment. However, most of the experimental surface dynamics work has been on the low-mass alkali halides with very little effort on higher energy modes or on the heavier alkali halides, where effects from relaxation might be important. The work of this paper explores these latter two conditions. Inelastic scattering of He atoms from the left-angle 110 right-angle NaI(001) surface has been used to obtain the acoustic S 1 Rayleigh mode, the S 6 longitudinal mode, and the S 8 crossing mode, however, no gap S 4 optical mode was seen. The results compare favorably with reported theoretical models employing both slab calculations and the Green's function method thus indicating that bulk parameters and the shell model go a long way in explaining most of the observations

  18. Iodine-131 in breast milk following therapy for thyroid carcinoma

    International Nuclear Information System (INIS)

    Robinson, P.S.; Barker, P.; Campbell, A.

    1994-01-01

    This study evaluates breast milk secretion of 131 I following therapeutic adminstration of 4000 MBq of 131 I-iodide during lactation. Breast milk 131 I activity concentration was measured over a 32-day period. Dosimetry calculations were undertaken to estimate the period for discontinuation of breast feeding and the equivalent dose to the breasts. To achieve an infant effective dose 131 I-iodide adminstration is not undertaken during lactation and that breast feeding is discontinued several days prior to administration. 26 refs., 2 figs., 2 tabs

  19. Thulium oxide fuel characterization study (thulium-170 fueled capsule parametric design)

    Energy Technology Data Exchange (ETDEWEB)

    DesChamps, N.H.

    1968-10-01

    A doubly encapsulated thulia wafer, i.e., individually lined wafers stacked one upon another inside a fuel capsule was studied. The temperature profiles were determined for thulia power densities ranging from 8 to 24 W/cc and fuel capsule surface temperatures ranging from 1000/sup 0/F (538/sup 0/C) to 2000/sup 0/F (1093/sup 0/C). Parametric studies were also carried out on a singly encapsulated configuration in which the thulia wafers were stacked face to face in an infinitely long, lined cylinder. The doubly encapsulated wafer configuration yielded a lower centerline temperature than the singly encapsulated capsule. Only in extreme cases of a large wafer diameter in combination with a high thulia power density did the fuel capsule centerline temperature exceed the thulia melt temperature of 4172/sup 0/F (2300/sup 0/C). Results are also given for the maximum radius attainable without having centerline melting when using a thulia microsphere fuel form.

  20. Is {sup 131}I ablation necessary for patients with low-risk papillary thyroid carcinoma and slightly elevated stimulated thyroglobulin after thyroidectomy?

    Energy Technology Data Exchange (ETDEWEB)

    Rosario, Pedro Weslley; Mourao, Gabriela Franco, E-mail: pedrowsrosario@gmail.com [Santa Casa de Belo Horizonte, MG (Brazil). Instituto de Ensino e Pesquisa

    2016-02-15

    Objective: This prospective study evaluated the recurrence rate in low-risk patients with papillary thyroid cancer (PTC) who presented slightly elevated thyroglobulin (Tg) after thyroidectomy and who did not undergo ablation with {sup 131}I. Subjects and methods: The study included 53 low-risk patients (non aggressive histology; pT1b-3, cN0pNx, M0) with slightly elevated Tg after thyroidectomy (> 1 ng/mL, but ≤ 5 ng/mL after levothyroxine withdrawal or ≤ 2 ng/mL after recombinant human TSH). Results: The time of follow-up ranged from 36 to 96 months. Lymph node metastases were detected in only one patient (1.9%). Fifty-two patients continued to present negative neck ultrasound. None of these patients without apparent disease presented an increase in Tg. Conclusions: Low-risk patients with PTC who present slightly elevated Tg after thyroidectomy do not require ablation with {sup 131}I. (author)

  1. Validating Inertial Confinement Fusion (ICF) predictive capability using perturbed capsules

    Science.gov (United States)

    Schmitt, Mark; Magelssen, Glenn; Tregillis, Ian; Hsu, Scott; Bradley, Paul; Dodd, Evan; Cobble, James; Flippo, Kirk; Offerman, Dustin; Obrey, Kimberly; Wang, Yi-Ming; Watt, Robert; Wilke, Mark; Wysocki, Frederick; Batha, Steven

    2009-11-01

    Achieving ignition on NIF is a monumental step on the path toward utilizing fusion as a controlled energy source. Obtaining robust ignition requires accurate ICF models to predict the degradation of ignition caused by heterogeneities in capsule construction and irradiation. LANL has embarked on a project to induce controlled defects in capsules to validate our ability to predict their effects on fusion burn. These efforts include the validation of feature-driven hydrodynamics and mix in a convergent geometry. This capability is needed to determine the performance of capsules imploded under less-than-optimum conditions on future IFE facilities. LANL's recently initiated Defect Implosion Experiments (DIME) conducted at Rochester's Omega facility are providing input for these efforts. Recent simulation and experimental results will be shown.

  2. Trade study for the disposition of cesium and strontium capsules

    International Nuclear Information System (INIS)

    Claghorn, R.D.

    1996-03-01

    This trade study analyzes alternatives for the eventual disposal of cesium and strontium capsules currently stored at the Waste Encapsulation and Storage Facility as by-product. However, for purposes of this study, it is assumed that at some time in the future, the capsules will be declared high-level waste and therefore will require disposal at an offsite geologic repository. The study considered numerous alternatives and selected three for detailed analysis: (1) overpack and storage at high-level waste canister storage building, (2) overpack at the high-level waste vitrification facility followed by storage at a high-level waste canister storage building, and (3) blend capsule contents with other high-level waste feed streams and vitrify at the high-level waste vitrification facility

  3. Clinical evaluation of 131I in treatment hyperthyroidism

    International Nuclear Information System (INIS)

    Wang Jing; Deng Jinglan; Qiao Hongqing

    2001-01-01

    The clinical value of 131 I in the treatment of hyperthyroidism is observed. The weight of the thyroid was evaluated by palpation, 131 I was taken orally by one dose method. The dose was calculated by actual absorption of 131 I/per gram of thyroid. 3 - 6 months after drug administration, the symptom, clinical manifestation and the serum hormone of the pituitary-hypothyroid axis were observed. In 105 cases, 80(76.2%) were nearly recovered, among them 16(15.2%) had hypothyroidism in the early period. The all over recovering rate was 91.4% in one dose, but 9(8.6%) were recurred and can be controlled at a second dose. Therefore 131 I for the hyperthyroidism had a high recovering rate, low recurring rate and was very convenient. If prospect on the Chinese effort the controlled, the occurrence of hypothyroidism can be reduced to the acceptable level

  4. Capsule-Preserving Hydrodilatation With Corticosteroid Versus Corticosteroid Injection Alone in Refractory Adhesive Capsulitis of Shoulder: A Randomized Controlled Trial.

    Science.gov (United States)

    Lee, Doo-Hyung; Yoon, Seung-Hyun; Lee, Michael Y; Kwack, Kyu-Sung; Rah, Ueon Woo

    2017-05-01

    To determine whether capsule-preserved hydrodilatation with corticosteroid improves pain and function in patients with refractory adhesive capsulitis (AC) better than intra-articular corticosteroid injection (IACI) alone. Prospective randomized controlled study. University-affiliated tertiary care hospital. Subjects with primary AC (N=64) with shoulder pain level of visual analog scale (VAS) score ≥5, even after the initial administration of IACI alone. Participants randomly received ultrasound-guided IACI alone with 1mL of 40mg/mL triamcinolone acetonide and 3mL of 1% lidocaine (n=32) or ultrasound-guided capsule-preserved hydrodilatation with corticosteroid with a mixture of 1mL of 40mg/mL triamcinolone acetonide, 6mL of 1% lidocaine, and normative saline (n=32). The primary outcome measure was the Shoulder Pain and Disability Index score. Secondary outcomes were the VAS of shoulder pain level and angles of shoulder passive range of motion, including flexion, abduction, extension, external rotation, and internal rotation at pretreatment and weeks 3, 6, and 12 of posttreatment. There were no significant differences between the 2 groups in terms of demographic characteristics (age, sex, duration of symptoms, shoulder affected, and body mass index) at baseline. Repeated-measures analysis of variance showed significant effect of time in all outcome measurements in both groups. However, group-by-time interactions were not significantly different for any of the outcomes between groups. This study shows that compared with pretreatment, all outcome measures improved significantly in both groups by time; however, there was no significant difference between the 2 groups. Therefore, we recommend IACI alone over capsule-preserved hydrodilatation with corticosteroid when considering the corticosteroid injection as a secondary option after the initial IACI fails to improve symptoms for patients with refractory AC. Copyright © 2016 American Congress of Rehabilitation

  5. Sensitive Detection of Deliquescent Bacterial Capsules through Nanomechanical Analysis.

    Science.gov (United States)

    Nguyen, Song Ha; Webb, Hayden K

    2015-10-20

    Encapsulated bacteria usually exhibit strong resistance to a wide range of sterilization methods, and are often virulent. Early detection of encapsulation can be crucial in microbial pathology. This work demonstrates a fast and sensitive method for the detection of encapsulated bacterial cells. Nanoindentation force measurements were used to confirm the presence of deliquescent bacterial capsules surrounding bacterial cells. Force/distance approach curves contained characteristic linear-nonlinear-linear domains, indicating cocompression of the capsular layer and cell, indentation of the capsule, and compression of the cell alone. This is a sensitive method for the detection and verification of the encapsulation status of bacterial cells. Given that this method was successful in detecting the nanomechanical properties of two different layers of cell material, i.e. distinguishing between the capsule and the remainder of the cell, further development may potentially lead to the ability to analyze even thinner cellular layers, e.g. lipid bilayers.

  6. SrF2 capsule design for heat engine applications

    International Nuclear Information System (INIS)

    Lester, D.H.

    1976-04-01

    A number of design changes were considered to improve heat transfer characteristics of the WESF capsule. This capsule was evaluated in a design concept for use as a heat source in a helium-working fluid, Stirling heat engine. Throughout the study a heat block concept was used. The helium was assumed to be at 1200 0 F and 200 atm. The upper temperature limit at the fuel-metal interface was assumed to be 800 0 C because of material compatibility considerations. A 0.6-in. thick outer can was considered since it may be required for impact resistance and high pressure accident environments. The modifications considered were: (1) filling all gaps with helium rather than air, (2) filling gaps with powdered metal, and (3) adding a third can to the existing capsule. Also, enhancement of emissivity on metal surfaces was considered as a possible modification

  7. The development and current status of 131I treatment for hyperthyroidism

    International Nuclear Information System (INIS)

    Wang Chunmei; Wang Xuemei

    2010-01-01

    Hyperthyroidism is an autoimmune diseasein which excessive amounts of thyroid hormones circulate in the blood. The treatments for hyperthyroidism mainly include antithyroid drugs, 131 I treatment, and surgery. 131 I had been verified as an effective, safe, simple method to treat adult and children hyperthyroidism. Current research trends of 131 I treatment mainly are problems of 131 I treatment of hyperthyroidism and its long-term security. (authors)

  8. Graves hyperthyroidism 131I treatment the clinical curative effect of observation

    International Nuclear Information System (INIS)

    Duan Yongqiang; Wang Zuobing; Yu Hui; Wang Jing; Li Xiaoqin; Chen Yuanhao; Wu Jiquan

    2012-01-01

    Objective: to study the clinical treatment of 131 I Graves hyperthyroidism curative effect. Methods: the clinical data of Graves hyperthyroidism patients were retrospectively analyzed. Results: 258 cases of patients with hyperthyroidism Graves. 131 I treatment 1∼2 times after healed 200 cases, improvement of 38 patients, a low, 10 cases were invalid 10 cases failure; the total effective 96.12%. 1 year after treatment 131 I thyroid quality by before treatment 43.6 + 20.9 grams shrinks to 1.98 + 18.5 grams (p 131 I before treatment with prominent eyes 68 cases (26.4%) 131 I after treatment, the prominent eyes healed 24 cases (34.8%), improvement 30 patients (43.5%), invalid in 12 cases (17.4%), aggravating in 2 cases (2.9%), efficient for 79.7%. Concurrent hyperthyroidism 131 I before treatment in patients with 31 patients (heart), after the treatment of 131 I 12.0% in 25 patients recovered, 6 patients get better, efficient 100%. After the treatment of 131 I temporary armor low in 25 patients (9.7%) , permanent armour low 27 cases (10.5%). After the treatment of 131 I 15 cases have been reduced to a sex WBC (5.8%), 8 cases of liver function mild damage (3.1%), 13 cases itchy skin (1 case), cholesterol by 5.0% compared appear suspected hyperthyroidism crises (0.4%). 258 patients with thyroid type micronodular 41 cases, treatment cured after 131 I in 25 patients (61.0%), improvement in 16 (39.0%), laseris 100%, Diffuse 217 example, cure 175 cases (80.6%), improvement 22 patients (10%), a low 10 (4.6%), invalid 10 (4.6%), laseris 95.4 percent. Conclusion: 131 I treatment Graves hyperthyroidism is simple, safe, effective, and can be used as the preferred treatment method outperforms that of anti-thyroid drugs. (authors)

  9. A generalized scaling law for the ignition energy of inertial confinement fusion capsules

    International Nuclear Information System (INIS)

    Herrmann, M.C.

    2001-01-01

    The minimum energy needed to ignite an inertial confinement fusion capsule is of considerable interest in the optimization of an inertial fusion driver. Recent computational work investigating this minimum energy has found that it depends on the capsule implosion history, in particular, on the capsule drive pressure. This dependence is examined using a series of LASNEX simulations to find ignited capsules which have different values of the implosion velocity, fuel adiabat and drive pressure. It is found that the main effect of varying the drive pressure is to alter the stagnation of the capsule, changing its stagnation adiabat, which, in turn, affects the energy required for ignition. To account for this effect a generalized scaling law has been devised for the ignition energy, E ign ∝α if 1.88±0.05 υ -5.89±0.12 P -0.77±0.03 . This generalized scaling law agrees with the results of previous work in the appropriate limits. (author)

  10. Work plan for testing silicone impression material and fixture on pool cell capsule

    International Nuclear Information System (INIS)

    Lundeen, J.E.

    1994-01-01

    The purpose of this work plan is to provide a safe procedure to test a cesium capsule impression fixture at Waste Encapsulation and Storage Facility (WESF). The impression will be taken with silicone dental impression material pressed down upon the capsule using the impression fixture. This test will evaluate the performance of the fixture and impression material under high radiation and temperature conditions on a capsule in a WESF pool cell

  11. /sup 131/I-meta-iodobenzylguanidine scintigraphy of neuroblastomas

    International Nuclear Information System (INIS)

    Munkner, T.

    1986-01-01

    Sixteen neuroblastoma patients have been studied by /sup 131/I-meta-iodobenzylguanidine scintigraphy. Three patients were possibly cured, and their scintigraphy results were normal. Thirteen patients had tumors and metastases demonstrated by /sup 131/I-MIBG, two of these patients had a normal vanillylmandelic acid excretion levels. One patient has been treated by /sup 131/I-MIBG, but died. /sup 131/I-MIBG was concentrated in other cells too, e.g., in erythrocytes and platelets. Neuroblastoma is the most common solid malignant disease in children. It has a poor prognosis in patients more than one year old. Early detection and a display of the spread of the tumor is of utmost importance for planning and controlling the treatment. Mass screening for neuroblastoma in infants has been suggested and tried in Japan. Scintigraphy after injection of /sup 131/I-meta-iodobenzylguanidine has been used successfully for locating neuroblastomas. An initial study failed to demonstrate neuroblastoma by means of MIBG in two patients. Since the latter part of 1983, MIBG has been used in a number of European centers for imaging neuroblastomas with very promising results, and a multicenter investigation has been initiated. The Ann Arbor group has recently extended its studies to a group of ten patients and has confirmed the European results

  12. Ultrahigh speed en face OCT capsule for endoscopic imaging.

    Science.gov (United States)

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G

    2015-04-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.

  13. Thermal Analysis of a Dry Storage Concept for Capsule Dry Storage Project

    International Nuclear Information System (INIS)

    JOSEPHSON, W.S.

    2003-01-01

    There are 1,936 cesium (Cs) and strontium (Sr) capsules stored in pools at the Waste Encapsulation and Storage Facility (WESF). These capsules will be moved to dry storage on the Hanford Site as an interim measure to reduce risk. The Cs/Sr Capsule Dry Storage Project is conducted under the assumption that the capsules will eventually be moved to the repository at Yucca Mountain, and the design criteria include requirements that will facilitate acceptance at the repository. The storage system must also permit retrieval of capsules in the event that vitrification of the capsule contents is pursued. The Capsule Advisory Panel (CAP) was created by the Project Manager for the Hanford Site Capsule Dry Storage Project (CDSP). The purpose of the CAP is to provide specific technical input to the CDSP; to identify design requirements; to ensure design requirements for the project are conservative and defensible; to identify and resolve emerging, critical technical issues, as requested; and to support technical reviews performed by regulatory organizations, as requested. The CAP will develop supporting and summary documents that can be used as part of the technical and safety bases for the CDSP. The purpose of capsule dry storage thermal analysis is to: (1) Summarize the pertinent thermal design requirements sent to vendors, (2) Summarize and address the assumptions that underlie those design requirements, (3) Demonstrate that an acceptable design exists that satisfies the requirements, (4) Identify key design features and phenomena that promote or impede design success, (5) Support other CAP analyses such as corrosion and integrity evaluations, and (6) Support the assessment of proposed designs. It is not the purpose of this report to optimize or fully analyze variations of postulated acceptable designs. The present evaluation will indicate the impact of various possible design features, but not systematically pursue design improvements obtainable through analysis

  14. Value of 201Tl imaging in predicting therapeutic 131I uptake in patients with thyroglobulin-positive but 131I scan-negative differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Conlu, R.A.O.; Obaldo, J.M.

    2004-01-01

    Background: Serum thyroglobulin assay and 131Iodine (1311) whole body scan are considered complementary in detecting malignant thyroid tissue or metastases. A large number of patients, however, are encountered presenting with scan-negative, thyroglobulin-positive differentiated thyroid carcinoma posing a dilemma in therapeutic management. One of the first alternative scanning agents to be employed is 201Thallium (201Tl). Recent studies have demonstrated its usefulness in identifying lesions that are not visualized with traditional 131I whole body scan. It is not clear, however, whether 201Tl scan helps in the decision-making for subsequent 131I therapy. This study was conducted to determine if 201Tl scan can predict therapeutic 131I uptake and to define the clinical role of 201Tl scanning in these patients. Methods and results: A total of 12 patients (20-63 y/o), 5 males and 7 females, underwent surgery for differentiated thyroid cancer and all had serum thyroglobulin values above 10 ng/ml and normal TPO autoantibodies. Pre-therapy 131I scan using 111 MBq (3mCi) of 131I were obtained. As required for inclusion, all patients had negative pre-therapy scan and negative TPO autoantibody results and underwent 20lTl scanning within 3 weeks. All patients were given 131I therapy (3.7-5.5 GBq or 100-150 mCi) between one to two months after 201Tl scanning. Within a week after therapy, all patients underwent whole body 1311 scanning. 201Tl imaging demonstrated thyroid remnants in 9 out of 12 patients having positive 201Tl scan but negative pre-therapy 1311 scan. However, only 2 of the positive 201Tl scans showed 131I uptake post-therapy (positive predictive value of 20%). None of the subjects presented with a negative 201Tl scan and a positive post-therapy 131I scan. Conclusion: Our study suggests that evidence of remnants or metastases on 201Tl scanning may be an inappropriate basis for the decision to proceed with 131I therapy. The role of 20lTl imaging in this subset of

  15. Transient hypothyroidism after 131I treatment of Graves disease

    International Nuclear Information System (INIS)

    Liu Jianfeng; Fang Yi; Zhang Xiuli; Ye Genyao; Xing Jialiu; Zhang Youren

    2003-01-01

    Objective: To evaluate the results of the transient hypothyroidism after 131 I treatment of Graves disease. Methods: A total of 32 transient hypothyroidism patients treated with 131 I for Graves disease were studied and followed up. Results: Transient hypothyroidism occurred within 2-6 months after 131 I treatment and 19 patients were symptomatic. At diagnosis of transient hypothyroidism, T 3 and T 4 levels were decreased had normal, TSH levels were increased, normal or low. Follow-up examination found that 20 patients were normal and 12 patients had relapse of hyperthyroidism. Conclusions: Therapy of Graves disease with low doses of 131 I causes a high incidence of transient hypothyroidism. After recovery of transient hypothyroidism, some patients have relapse of hyperthyroidism

  16. Comparison of 131I whole-body imaging, 131I SPECT/CT, and 18F-FDG PET/CT in the detection of metastatic thyroid cancer

    International Nuclear Information System (INIS)

    Oh, Jong-Ryool; Chong, Ari; Kim, Jahae; Kang, Sae-Ryung; Song, Ho-Chun; Bom, Hee-Seung; Byun, Byung-Hyun; Hong, Sun-Pyo; Yoo, Su-Woong; Kim, Dong-Yeon; Min, Jung-Joon

    2011-01-01

    The aim of this study was to compare 131 I whole-body scintigraphy (WBS), WBS with 131 I single photon emission computed tomography/computed tomography (SPECT/CT), and 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT in the detection of distant metastases of differentiated thyroid cancer (DTC). A total of 140 patients with 258 foci of suspected distant metastases were evaluated. 131 I WBS, 131 I SPECT/CT, and 18 F-FDG PET/CT images were interpreted separately. The final diagnosis was obtained from histopathologic study, serum thyroglobulin level, other imaging modalities, and/or clinical follow-up. Of the 140 patients with 258 foci, 46 patients with 166 foci were diagnosed as positive for distant metastasis. The sensitivity, specificity, and diagnostic accuracy of each imaging modality were 65, 55, and 59%, respectively, for 131 I WBS; 65, 95, and 85% for 131 I SPECT/CT, respectively; and 61, 98, and 86%, respectively, for 18 F-FDG PET/CT in patient-based analyses. Lesion-based analyses demonstrated that both SPECT/CT and PET/CT were superior to WBS (p 18 F-FDG PET/CT presented the highest diagnostic performance in patients who underwent multiple challenges of radioiodine therapy. (orig.)

  17. The position control of a capsule filled with magnetic fluid

    International Nuclear Information System (INIS)

    Rhee, E.J.; Park, M.K.; Yamane, R.; Oshima, S.

    2002-01-01

    In this paper, in order to establish the technique of a nozzle-flapper system of a servo valve using magnetic fluid in hydraulic system, a governing equation regarding the levitation of a capsule filled with magnetic fluid is formulated. Using PID control, an experiment for the position control of a capsule was performed. The experimental results were compared with the simulation results found by the governing equation

  18. Interventional microadhesiolysis: A new nonsurgical release technique for adhesive capsulitis of the shoulder

    Directory of Open Access Journals (Sweden)

    Lim Tae-Kyun

    2008-01-01

    Full Text Available Abstract Background A nonsurgical intervention, interventional microadhesiolysis, was developed to release adhesions in joints and soft tissues. This paper introduces the procedure and evaluates the efficacy of the intervention for adhesive capsulitis of the shoulder. Methods Ten patients (five men and five women with primary adhesive capsulitis of the shoulder were treated at a chronic pain management center in Korea. Three specially made needles are used in interventional microadhesiolysis: the Round, Flexed Round, and Ahn's needles. A Round Needle is inserted on the skin over middle of supraspinatus and advanced under the acromion and acromioclavicular joint (subacromial release. A Flexed Round Needle is inserted two-fingers caudal to the inferior border of the scapular spine and advanced over the capsule sliding on the surface of infraspinatus muscle-tendon fascia. The capsule is released while an assistant simultaneously passively abducts the shoulder to full abduction (posteroinferior capsule release. An Ahn's Needle is inserted on the skin over the lesser tubercle and advanced under the coracoid process sliding on the surface of the subscapularis muscle (subcoracoid release. Results After the patients underwent interventional microadhesiolysis, the self-rated pain score or severity declined significantly (p p Conclusion Our findings suggest that interventional microadhesiolysis is effective for managing adhesive capsulitis of the shoulder.

  19. Beta-endorphin 1-31 biotransformation and cAMP modulation in inflammation.

    Directory of Open Access Journals (Sweden)

    Naghmeh Hajarol Asvadi

    Full Text Available A large body of evidence now exists for the immune cell expression, production, and the release of beta-endorphin (BE 1-31 within inflamed tissue. The inflammatory milieu is characterised by increased acidity, temperature and metabolic activity. Within these harsh conditions BE 1-31 is even more susceptible to increased enzymatic degradation over that of plasma or other non-injured tissue. To elucidate the biotransformation pathways of BE 1-31 and provide an insight to the impact of inflamed tissue environments, BE 1-31 and three of its major N-terminal fragments (BE 1-11, BE 1-13 and BE 1-17 were incubated in inflamed tissue homogenates at pH 5.5 for 2 hrs. In addition, the potency of BE 1-31 and five main N--terminal fragments (BE 1-9, BE 1-11, BE 1-13, BE 1-17, BE 1-20 was assessed at mu-opioid receptors (MOR, delta-opioid receptors (DOR, and kappa-opioid receptors (KOR. Opioid receptor potency was investigated by examining the modulation of forskolin induced cAMP accumulation. The majority of the N-terminal fragment of BE 1-31 had similar efficacy to BE 1-31 at MOR. The shortest of the major N-terminal fragments (BE 1-9, had partial agonist activity at MOR but possessed the highest potency of all tested peptides at DOR. There was limited effect for BE 1-31 and the biotransformed peptides at KOR. Major N-terminal fragments produced within inflamed tissue have increased presence within inflamed tissue over that of the parent molecule BE 1-31 and may therefore contribute to BE 1-31 efficacy within disease states that involve inflammation.

  20. Matrix polyelectrolyte capsules based on polysaccharide/MnCO₃ hybrid microparticle templates.

    Science.gov (United States)

    Wei, Qingrong; Ai, Hua; Gu, Zhongwei

    2011-06-15

    An efficient strategy for biomacromolecule encapsulation based on spontaneous deposition into polysaccharide matrix-containing capsules is introduced in this study. First, hybrid microparticles composed of manganese carbonate and ionic polysaccharides including sodium hyaluronate (HA), sodium alginate (SA) and dextran sulfate sodium (DS) with narrow size distribution were synthesized to provide monodisperse templates. Incorporation of polysaccharide into the hybrid templates was successful as verified by thermogravimetric analysis (TGA) and confocal laser scanning microscopy (CLSM). Matrix polyelectrolyte microcapsules were fabricated through layer-by-layer (LbL) self-assembly of oppositely charged polyelectrolytes (PEs) onto the hybrid particles, followed by removal of the inorganic part of the cores, leaving polysaccharide matrix inside the capsules. The loading and release properties of the matrix microcapsules were investigated using myoglobin as a model biomacromolecule. Compared to matrix-free capsules, the matrix capsules had a much higher loading capacity up to four times; the driving force is mostly due to electrostatic interactions between myoglobin and the polysaccharide matrix. From our observations, for the same kind of polysaccharide, a higher amount of polysaccharide inside the capsules usually led to better loading capacity. The release behavior of the loaded myoglobin could be readily controlled by altering the environmental pH. These matrix microcapsules may be used as efficient delivery systems for various charged water-soluble macromolecules with applications in biomedical fields. Copyright © 2010 Elsevier B.V. All rights reserved.

  1. /sup 131/I-BSP liver function test by BSP tolerance

    Energy Technology Data Exchange (ETDEWEB)

    Kanda, K [Minami Osaka Hospital (Japan)

    1974-11-01

    /sup 131/I-BSP liver function test after BSP intravenous tolerance was discussed, assuming that the reason why measurements of /sup 131/I-BSP retention rate at 30 minutes and /sup 131/I-BSP disappearance rate in blood showed respectable overlapping between normal group and group with slight liver disorders as compared with BSP test and the reason why differential diagnosis was difficult were due to underestimate of tolerance volume of /sup 131/I-BSP. /sup 131/I-BSP was observed with time as to 70 persons with normal liver function and 257 cases of liver diseases, using 5, 3 and 2 mg of non-radioactive BSP tolerance volume per kilogram of body weight. /sup 131/I-BSP retention rate at 30 minutes and /sup 131/I-BSP disappearance rate in blood are possible to separate overlapping over control in each measurement value at 3 to 5 mg/kg of tolerance, and in comparison of 3 mg and 5 mg, the latter showed a little excellent result. So, it was decided that tolerance of 3 mg/kg was a proper dose, considering tolerance to liver cells. /sup 131/I-BSP retention rate at 30 minutes was a little excellent in accuracy and disappearance rate in blood after BSP tolerance is simple and profitable for practical use because collection of blood was only one time and measurement could be made with whole blood. As mentioned above, this method is seemed to be useful to practice of liver function test.

  2. Egg capsules of the dusky catshark Bythaelurus canescens (Carcharhiniformes, Scyliorhinidae) from the south-eastern Pacific Ocean.

    Science.gov (United States)

    Concha, F; Bustamante, C; Oddone, M C; Hernández, S; Lamilla, J

    2010-09-01

    The external morphology of the egg capsule of Bythaelurus canescens and its fixation to the substratum are described. Bythaelurus canescens egg capsules are typically vase-shaped, dorso-ventrally flattened, pale yellow in colour when fresh and covered by 12-15 longitudinal ridges. The anterior border of the capsule is straight, whereas the posterior border is semicircular. Two horns bearing long, coiled tendrils arise from the anterior and posterior ends of the capsule. The presence of longitudinal ridges and long coiled tendrils at both anterior and posterior ends of the capsule readily distinguish these egg capsules from those of other chondrichthyans occurring in the south-east Pacific Ocean. © 2010 The Authors. Journal compilation © 2010 The Fisheries Society of the British Isles.

  3. β-CIT labelled with 131I and its preliminary clinical practice

    International Nuclear Information System (INIS)

    Ye Bin; Kuang Anren; Ding Hao; Zheng Hongbo; Yuan Qiang; He Li

    2002-01-01

    β-CIT is labelled with 131 I by the peracetic acid method. 4 normal controls, 8 patients with PD and 3 patients with PS are studied by 131 I-β-CIT SPECT imaging. Striatal specific uptake of 131 I-β-CIT is calculated by the radioactivity ratio of striatal to cerebellar. The results shows that the radiochemical purity of 131 I-β-CIT is (97.6 +- 0.3)%. 131 I-β-CIT remains stable for at least 4 h after incubated with waters and serum respectively. The striatal specific uptake of 131 I-β-CIT in normal controls, PD and PS patients are (4.39 +- 0.14)%, (2.95 +- 0.68)% and (3.96 +- 0.52)% at 4h and (6.60 +- 0.06)%, (3.85 +- 0.71)% and (6.14 +- 0.08)% at 20 h after administration. There is a significant reduction of striatal tracer uptake in PD patients compared to the controls and PS patients. Striatal specific uptake in contralateral to the clinical symptom side is more pronounced reduced than the ipsilateral side in PD patients. 131 I-β-CIT uptake in PD patients is correlated with disease severity. These results suggest that 131 I-β-CIT can be used for the diagnosis of Parkinsion's disease

  4. Structural analysis on the open basket type instrumented capsule for fuel irradiation tests in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Do Sik; Kang, Y. H.; Kim, B. G.; Cho, M. S.; Sohn, J. M.; Choo, K. N.; Oh, J. M.; Shin, Y. T.; Park, S. J. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-05-01

    To develop the open basket type instrumented capsule to be used for the irradiation test of various nuclear fuels, it is necessary to ensure the compatibility of the capsule with HANARO and the structural integrity of the capsule. The dimensions of the open basket type instrumented capsule were determined in the basis of the pressure drop criteria in OR test hole of HANARO(mass flow rate <12.7kg/s, pressure drop {delta}P>200kPa). From the buckling stability analysis for this capsule, the critical buckling load P{sub cr} was 7.5kN. The vertical impact stress of the capsule under unit impact load was evaluated by the transient analysis, and the maximum vertical impact load calculated from the impact stress and the allowable stress was 60.5kN. Under the loading of the calculated Pcr, the maximum vertical impact stress was 20.4MPa. The structural integrity of the capsule under a horizontal impact loading was also examined. The mechanical stresses occurred by the pressure difference at the inner and outer surface of cladding and by the coolant pressure at the surface of cladding were 3.1MPa and 43.3MPa, respectively. These stress values were lower than the allowable stress in each case. Therefore, it was ensured that the instrumented capsule for the irradiation test of various nuclear fuels met the criteria on the structural integrity during installing and testing the capsule in HANARO. 8 refs., 61 figs., 3 tabs. (Author)

  5. Visualization of adrenocortical carcinoma with /sup 131/I-Adosterol

    Energy Technology Data Exchange (ETDEWEB)

    Maruoka, Shin; Nakamura, Mamoru

    1987-01-01

    There are very few literatures on successful visualization of adrenocortical carcinoma by means of /sup 131/I-iodocholesterol scintigraphy, although many reports have referred to utility of /sup 131/I-iodocholesterol scintigraphy for adrenal disorders. Since 1976, we have experienced 4 cases of adrenocortical carcinoma which were delineated by /sup 131/I-6US -iodomethyl-19-norcholesterol (/sup 131/I-Adosterol). Three of 4 cases were adrenocortical carcinoma with Cushing's syndrome, and one was adrenocortical carcinoma with adrenogenital syndrome. In 3 cases of cortisol secreting adrenocortical carcinoma, uptake in the tumor and lack of uptake in the contralateral adrenal gland were seen. Faint to moderate uptakes were observed in the 2 cases, but another one showed as high uptake as seen in adenoma. Patient with androgen secreting adrenocortical carcinoma had increased uptake in the tumor and showed faint uptake in the contralateral adrenal gland. Intensity of /sup 131/I-Adosterol uptake in adrenocortical carcinoma seems to depend on the extent of tumor necrosis, cell differentiation and function.

  6. Unremitted hyperthyroidism following 131I treatment: an analysis of clinical markers in 48 patients

    International Nuclear Information System (INIS)

    Fang Yi; Zhang Xiuli; Liu Jianfeng; Zhang Youren

    2002-01-01

    Objective: To evaluate changes in clinical markers of unremitted hyperthyroidism patients after the first 131 I treatment. Methods: Forth eight unremitted hyperthyroidism patients were selected. Their thyroid function, the peak of 131 I uptake rate and thyroid weight before and after 131 I treatment were compared. Results: TT 3 , TT 4 , TSH were relatively stable and the peak of 131 I uptake rate and thyroid weight were reduced after 131 I treatment. Conclusions: Thyroid volume was reduced after 131 I treatment even if patients' clinical symptoms still existed; the peak of 131 I uptake rate was reduced after 131 I treatment, suggesting that their sensibility to 131 I decreased, so the absorbed dose should be adjusted when the 131 I dosage of second treatment is calculated

  7. Method and apparatus for dispensing small quantities of mercury from evacuated and sealed glass capsules

    Science.gov (United States)

    Grossman, Mark W.; George, William A.; Pai, Robert Y.

    1985-01-01

    A technique for opening an evacuated and sealed glass capsule containing a material that is to be dispensed which has a relatively high vapor pressure such as mercury. The capsule is typically disposed in a discharge tube envelope. The technique involves the use of a first light source imaged along the capsule and a second light source imaged across the capsule substantially transversely to the imaging of the first light source. Means are provided for constraining a segment of the capsule along its length with the constraining means being positioned to correspond with the imaging of the second light source. These light sources are preferably incandescent projection lamps. The constraining means is preferably a multiple looped wire support.

  8. Capsule Typing of Haemophilus influenzae by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry.

    Science.gov (United States)

    Månsson, Viktor; Gilsdorf, Janet R; Kahlmeter, Gunnar; Kilian, Mogens; Kroll, J Simon; Riesbeck, Kristian; Resman, Fredrik

    2018-03-01

    Encapsulated Haemophilus influenzae strains belong to type-specific genetic lineages. Reliable capsule typing requires PCR, but a more efficient method would be useful. We evaluated capsule typing by using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Isolates of all capsule types (a-f and nontypeable; n = 258) and isogenic capsule transformants (types a-d) were investigated. Principal component and biomarker analyses of mass spectra showed clustering, and mass peaks correlated with capsule type-specific genetic lineages. We used 31 selected isolates to construct a capsule typing database. Validation with the remaining isolates (n = 227) showed 100% sensitivity and 92.2% specificity for encapsulated strains (a-f; n = 61). Blinded validation of a supplemented database (n = 50) using clinical isolates (n = 126) showed 100% sensitivity and 100% specificity for encapsulated strains (b, e, and f; n = 28). MALDI-TOF mass spectrometry is an accurate method for capsule typing of H. influenzae.

  9. Physics of ignition for ICF capsules

    International Nuclear Information System (INIS)

    Lindl, J.D.

    1989-01-01

    The implosion of an ICF capsule must accomplish both compression of the main fuel to several hundred grams per cubic centimeter and heating and compression of the central region of the fuel to ignition. This report discusses the physics of these conditions

  10. Radiation research of materials using irradiation capsules

    International Nuclear Information System (INIS)

    Chamrad, B.

    1976-01-01

    The methods are briefly characterized of radiation experiments on the WWR-S research reactor. The irradiation capsule installed in the reactor including the electronic instrumentation is described. Irradiated samples temperature is stabilized by an auxiliary heat source placed in the irradiation space. The electronic control equipment of the system is automated. In irradiation experiments, experimental and operating conditions are recorded by a digital measuring centre with electric typewriter and paper tape data recording and by an analog compensating recorder. The irradiation experiment control system controls irradiated sample temperature, the supply current size and the heating element temperature of the auxiliary stabilizing source, inert and technological pressures of the capsule atmosphere and the thermostat temperature of the thermocouple junctions. (O.K.)

  11. 47 CFR 25.131 - Filing requirements for receive-only earth stations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Filing requirements for receive-only earth stations. 25.131 Section 25.131 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES SATELLITE COMMUNICATIONS Applications and Licenses Earth Stations § 25.131 Filing...

  12. The normal and abnormal distribution of the adrenomedullary imaging agent m-[I-131]iodobenzylguanidine (I-131 MIBG) in man: evaluation by scintigraphy

    International Nuclear Information System (INIS)

    Nakajo, M.; Shapiro, B.; Copp, J.; Kalff, V.; Gross, M.D.; Sisson, J.C.; Beierwaltes, W.H.

    1983-01-01

    The scintigraphic distribution of m-[ 131 I]iodobenzylguanidine (I- 131 MIBG), an adrenal medullary imaging agent, was studied to determine the patterns of uptake of this agent in man. The normal distribution of I- 131 MIBG includes clear portrayal of the salivary glands, liver, spleen, and urinary bladder. The heart, middle and lower lung zones, and colon were less frequently or less clearly seen. The upper lung zones and kidneys were seldom visualized. The thyroid appeared only in cases of inadequate thyroidal blockade. The ''normal'' adrenal glands were seldom seen and faintly imaged in 2% at 24 hr after injection and in 16% at 48 hr, in patients shown not to have pheochromocytomas, whereas intra-adrenal, extraadrenal, and malignant pheochromocytomas usually appeared as intense focal areas of I- 131 MIBG uptake at 24 through 72 hr

  13. Therapeutical uses of 131I

    International Nuclear Information System (INIS)

    Lago, Graciela.

    1994-01-01

    Physiology of thyroid gland, pathology of thyroid , papillary, follicular cancer is considered together as differentiated thyroid cancer with very good results under therapy with iodine, invitro determination of calcitonin, search of metastasis, anaplastic carcinoma, as indifferentiated carcinoma with similar results as medullary carcinoma. This work gives a protocol for therapeutical use of 131I , in hyperthyroidism due to Graves-Basedow disease, thyrotoxic adenoma or Plummer disease, toxic multi nodular goiter, subacute thyroiditis. Is studied too the treatment with pharmaceuticals, surgery and radioactive iodine. A recommended use of each and protocol for iodine administration, fixed dose technique, dose estimation,absorbed dose, recommendations about when to use and not use 131I are included in this work

  14. Review of safety issues that pertain to the use of WESF cesium chloride capsules in an irradiator

    International Nuclear Information System (INIS)

    Tingey, G.L.; Wheelwright, E.J.; Lytle, J.M.

    1984-07-01

    Since the recovery of the fission product cesium-137 began in 1967, about 1500 capsules, each containing an average of about 50,000 curies of cesium chloride, have been produced. These capsules were designed to safely store this gamma-emitting fission product, but they are now considered to be a valuable source for irradiators. The capsules were designed to have a large margin of safety in their mechanical properties. Impact, percussion, and thermal tests have been conducted that demonstrate their ability to meet anticipated licensing requirements. Although this document is not intended to develop or evaluate accident scenarios, an examination of the effects of heating a capsule to 800 0 C for up to 90 min was completed. At 800 0 C, the salt volume would be expected to exceed the initial capsule volume in a few (up to 1/3) of the WESF capsules. Under these conditions, the inner capsule would expand to accommodate the salt volume and the gas pressure. The strength and ductility of the capsule are more than adequate to permit this expansion with a safety margin of at least a factor of three. Capsules have now been stored in the WESF pool for 10 years, and 15 capsules have been used in the Sandia Irradiator for Dried Sewage Solids facility for nearly 5 years without any capsule failure. This experience, along with available laboratory and production data, gives reasonable assurance that the capsules can be safely used in properly designed commercial irradiators. This is especially the case when one considers current and future evaluation programs designed to assess the long-term effects of corrosion and mechanical properties degradation

  15. The highest spin discrete levels in 131,132Ce

    International Nuclear Information System (INIS)

    Paul, E S; Choy, P T W; Andreoiu, C; Boston, A J; Evans, A O; Fox, C; Gros, S; Nolan, P J; Rainovski, G; Sampson, J A; Scraggs, H C; Walker, A; Appelbe, D E; Joss, D T; Simpson, J; Gizon, J; Astier, A; Buforn, N; Prevost, A; Redon, N; Stezowski, O; Nyako, B M; Sohler, D; Timar, J; Zolnai, L; Bazzacco, D; Lunardi, S; Petrache, C M; Bednarczyk, P; Curien, D; Kintz, N; Ragnarsson, I

    2006-01-01

    The three superdeformed (SD) bands in 132 Ce and the two SD bands in 131 Ce have been extended to higher spin following experiments with the EUROBALL IV spectrometer. The two SD bands in 131 Ce have been linked together. However, despite the relatively high population intensity of the bands (up to 5% of the respective channel), it has not been possible to unambiguously link any of the five SD bands into the low-spin, normally deformed structures of 131,132 Ce

  16. Fabrication, characterization and evaluation of bacterial cellulose-based capsule shells for oral drug delivery

    DEFF Research Database (Denmark)

    Ullah, Hanif; Badshah, Munair; Mäkilä, Ermei

    2017-01-01

    Bacterial cellulose (BC) was investigated for the first time for the preparation of capsule shells for immediate and sustained release of drugs. The prepared capsule shells were characterized using X-ray diffraction, scanning electron microscopy and Fourier transform infrared spectroscopy. The BC...... to gelatin capsules with both immediate and sustained drug release properties depending upon the compositions of the encapsulated materials....

  17. A study for the development of the capsule assembly machine for the re-irradiation test

    International Nuclear Information System (INIS)

    Kang, Y. H.; Kim, J. K.; Yeom, K. Y.; Yoon, K. B.; Choi, M. H.; Kim, B. K.

    2004-01-01

    A series of in-pile tests are being carried out to support the advanced fuel development programs at the HANARO reactor. There are still some limitations for satisfying the test requirements. To meet the demands for the high burnup test at HANARO, new capsule assembling technology is required. This paper describes the design requirements, design and fabrication of the mockup, and pre-operational tests performed for the development of the new capsule assembly machine. The mockup manufactured consists of a base plate, a capsule stand, a capsule guide pipe and clamping device and is 1m in outer diameter, 1.8m in height and 136kg in weight. From the pre-operation tests, the optimum clamping torque was 450kgf·cm for preventing rotation and shaking of the capsule main body during assembling capsule main body and protection tube, and this remote assembling procedure can be applicable to the high burnup test

  18. Summary of the irradiation history of the TRIST-ER1 capsule

    Energy Technology Data Exchange (ETDEWEB)

    Qualls, A.L.; Eatherly, W.S.; Heatherly, D.W. [Oak Ridge National Lab., TN (United States)

    1996-10-01

    The TRIST-ERI capsule was assembled and irradiated in a large Removable Beryllium (RB{star}) position of the High Flux Isotope Reactor (HFIR) during this reporting period. Irradiation began on March 8, 1996, was completed on June 20, 1996, during operating cycles 344, 345, and 346. This report describes the thermal operation of the capsule.

  19. Behavior of medically-derived 131I in the tidal Potomac River

    International Nuclear Information System (INIS)

    Rose, Paula S.; Smith, Joseph P.; Cochran, J. Kirk; Aller, Robert C.; Swanson, R. Lawrence

    2013-01-01

    Iodine-131 (t 1/2 = 8.04 d) is administered to patients for treatment of thyroid disorders, excreted by patients and discharged to surface waters via sewage effluent. Radionuclides generally behave like their stable analogs; therefore, medically-derived 131 I is useful as a transport-reaction tracer of anthropogenic inputs and the aquatic biogeochemistry of iodine. Iodine-131 was measured in Potomac River water and sediments in the vicinity of the Blue Plains Water Pollution Control Plant (WPCP), Washington, DC, USA. Concentrations measured in sewage effluent from Blue Plains WPCP and in the Potomac River suggest a relatively continuous source of this radionuclide. The range of 131 I concentrations detected in surface water was 0.076 ± 0.006 to 6.07 ± 0.07 Bq L −1 . Iodine-131 concentrations in sediments ranged from 1.3 ± 0.8 to 117 ± 2 Bq kg −1 dry weight. Partitioning in the sewage effluent from Blue Plains and in surface waters indicated that 131 I is associated with colloidal and particulate organic material. The behavior of medically-derived 131 I in the Potomac River is consistent with the nutrient-like behavior of natural iodine in aquatic environments. After discharge to the river via sewage effluent, it is incorporated into biogenic particulate material and deposited in sediments. Solid phase sediment profiles of 131 I indicated rapid mixing or sedimentation of particulate debris and diagenetic remineralization and recycling on short time scales. - Highlights: ► Medically-derived 131 I was measured in sewage effluent, river water, and sediments. ► Sediment 210 Pb and 7 Be profiles help characterize the sedimentary environment. ► 131 I flux to sediments in study area is ∼ 1% of that discharged in sewage effluent. ► 131 I distributions constrain reaction-transport processes to weekly time scales. ► Collectively these data are used to better understand iodine biogeochemistry

  20. I131-meta-iodobenzylguanidine in the diagnosis and treatment of neural crest tumours

    International Nuclear Information System (INIS)

    Hoefnagel, C.A.; Hartog Jager, F.C.A. den; Taal, B.G.; Engelsman, E.; Kraker, J. de; Voute, P.A.

    1988-01-01

    Iodine-131-meta-iodobenzylguanidine (I-131-MIBG) was used for scintigraphic detection and therapy of neural crest tumours. The methodology of both techniques is described. Based upon experience with I-131-MIBG-scintigraphy in 170 patients with neural crest tumours, of whom 46 received multiple therapeutic doses of I-131-MIBG, and upon the cumulative reports in the literature, the role of I-131-MIBG in diagnosis and treatment of each of these diseases is indicated. I-131-MIBG-scintigraphy is one of the most sensitive and specific techniques for the diagnosis, staging and follow-up of phaeochromocytoma and neuroblastoma and I-131-MIBG-therapy may induce remission in a number of these patients. In carcinoid and medullary thyroid carcinoma the diagnostic sensitivity is less; however, once the diagnosis has been made, it is useful to establish that the tumour concentrates I-131-MIBG, to see if the patients at some point in time may be amenable to I-131-MIBG-therapy