  1. A model for ultrasound contrast agent in a phantom vessel

    KAUST Repository

    Qamar, Adnan; Samtaney, Ravi

    2014-01-01

    A theoretical framework to model the dynamics of Ultrasound Contrast Agent (UCA) inside a phantom vessel is presented. The model is derived from the reduced Navier-Stokes equation and is coupled with the evolving flow field solution inside

  2. A model for ultrasound contrast agent in a phantom vessel

    KAUST Repository

    Qamar, Adnan

    2014-02-01

    A theoretical framework to model the dynamics of Ultrasound Contrast Agent (UCA) inside a phantom vessel is presented. The model is derived from the reduced Navier-Stokes equation and is coupled with the evolving flow field solution inside the vessel by a similarity transformation approach. The results are computed, and compared with experiments available in literature, for the initial UCA radius of Ro=1.5 μm and 2 μm for the vessel diameter of D=12 μm and 200 μm with the acoustic parameters as utilized in the experiments. When compared to other models, better agreement on smaller vessel diameter is obtained with the proposed coupled model. The model also predicts, quite accurately, bubble fragmentation in terms of acoustic and geometric parameters. © 2014 IEEE.

  3. Paraffin-gel tissue-mimicking material for ultrasound-guided needle biopsy phantom.

    Science.gov (United States)

    Vieira, Sílvio L; Pavan, Theo Z; Junior, Jorge E; Carneiro, Antonio A O

    2013-12-01

    Paraffin-gel waxes have been investigated as new soft tissue-mimicking materials for ultrasound-guided breast biopsy training. Breast phantoms were produced with a broad range of acoustical properties. The speed of sound for the phantoms ranged from 1425.4 ± 0.6 to 1480.3 ± 1.7 m/s at room temperature. The attenuation coefficients were easily controlled between 0.32 ± 0.27 dB/cm and 2.04 ± 0.65 dB/cm at 7.5 MHz, depending on the amount of carnauba wax added to the base material. The materials do not suffer dehydration and provide adequate needle penetration, with a Young's storage modulus varying between 14.7 ± 0.2 kPa and 34.9 ± 0.3 kPa. The phantom background material possesses long-term stability and can be employed in a supine position without changes in geometry. These results indicate that paraffin-gel waxes may be promising materials for training radiologists in ultrasound biopsy procedures. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  4. A review of the benefits and pitfalls of phantoms in ultrasound-guided regional anesthesia.

    Science.gov (United States)

    Hocking, Graham; Hebard, Simon; Mitchell, Christopher H

    2011-01-01

    With the growth of ultrasound-guided regional anesthesia, so has the requirement for training tools to practice needle guidance skills and evaluate echogenic needles. Ethically, skills in ultrasound-guided needle placement should be gained in a phantom before performance of nerve blocks on patients in clinical practice. However, phantom technology is varied, and critical evaluation of the images is needed to understand their application to clinical use. Needle visibility depends on the echogenicity of the needle relative to the echogenicity of the tissue adjacent the needle. We demonstrate this point using images of echogenic and nonechogenic needles in 5 different phantoms at both shallow angles (20 degrees) and steep angles (45 degrees). The echogenicity of phantoms varies enormously, and this impacts on how needles are visualized. Water is anechoic, making all needles highly visible, but does not fix the needle to allow practice placement. Gelatin phantoms and Blue Phantoms provide tactile feedback but have very low background echogenicity, which greatly exaggerates needle visibility. This makes skill acquisition easier but can lead to false confidence in regard to clinical ability. Fresh-frozen cadavers retain much of the textural feel of live human tissue and are nearly as echogenic. Similar to clinical practice, this makes needles inserted at steep angles practically invisible, unless they are highly echogenic. This review describes the uses and pitfalls of phantoms that have been described or commercially produced. Copyright © 2011 by American Society of Regional Anesthesia and Pain Medicine

  5. Design and development of an ultrasound calibration phantom and system

    Science.gov (United States)

    Cheng, Alexis; Ackerman, Martin K.; Chirikjian, Gregory S.; Boctor, Emad M.

    2014-03-01

    Image-guided surgery systems are often used to provide surgeons with informational support. Due to several unique advantages such as ease of use, real-time image acquisition, and no ionizing radiation, ultrasound is a common medical imaging modality used in image-guided surgery systems. To perform advanced forms of guidance with ultrasound, such as virtual image overlays or automated robotic actuation, an ultrasound calibration process must be performed. This process recovers the rigid body transformation between a tracked marker attached to the ultrasound transducer and the ultrasound image. A phantom or model with known geometry is also required. In this work, we design and test an ultrasound calibration phantom and software. The two main considerations in this work are utilizing our knowledge of ultrasound physics to design the phantom and delivering an easy to use calibration process to the user. We explore the use of a three-dimensional printer to create the phantom in its entirety without need for user assembly. We have also developed software to automatically segment the three-dimensional printed rods from the ultrasound image by leveraging knowledge about the shape and scale of the phantom. In this work, we present preliminary results from using this phantom to perform ultrasound calibration. To test the efficacy of our method, we match the projection of the points segmented from the image to the known model and calculate a sum squared difference between each point for several combinations of motion generation and filtering methods. The best performing combination of motion and filtering techniques had an error of 1.56 mm and a standard deviation of 1.02 mm.

  6. Vessel bifurcation localization based on intraoperative three-dimensional ultrasound and catheter path for image-guided catheter intervention of oral cancers.

    Science.gov (United States)

    Luan, Kuan; Ohya, Takashi; Liao, Hongen; Kobayashi, Etsuko; Sakuma, Ichiro

    2013-03-01

    We present a method to localize intraoperative target vessel bifurcations under bones for ultrasound (US) image-guided catheter interventions. A catheter path is recorded to acquire skeletons for the target vessel bifurcations that cannot be imaged by intraoperative US. The catheter path is combined with the centerlines of the three-dimensional (3D) US image to construct a preliminary skeleton. Based on the preliminary skeleton, the orientations of target vessels are determined by registration with the preoperative image and the bifurcations were localized by computing the vessel length. An accurate intraoperative vessel skeleton is obtained for correcting the preoperative image to compensate for vessel deformation. A reality check of the proposed method was performed in a phantom experiment. Reasonable results were obtained. The in vivo experiment verified the clinical workflow of the proposed method in an in vivo environment. The accuracy of the centerline length of the vessel for localizing the target artery bifurcation was 2.4mm. These results suggest that the proposed method can allow the catheter tip to stop at the target artery bifurcations and enter into the target arteries. This method can be applied for virtual reality-enhanced image-guided catheter intervention of oral cancers. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Anatomically realistic ultrasound phantoms using gel wax with 3D printed moulds

    Science.gov (United States)

    Maneas, Efthymios; Xia, Wenfeng; Nikitichev, Daniil I.; Daher, Batol; Manimaran, Maniragav; Wong, Rui Yen J.; Chang, Chia-Wei; Rahmani, Benyamin; Capelli, Claudio; Schievano, Silvia; Burriesci, Gaetano; Ourselin, Sebastien; David, Anna L.; Finlay, Malcolm C.; West, Simeon J.; Vercauteren, Tom; Desjardins, Adrien E.

    2018-01-01

    Here we describe methods for creating tissue-mimicking ultrasound phantoms based on patient anatomy using a soft material called gel wax. To recreate acoustically realistic tissue properties, two additives to gel wax were considered: paraffin wax to increase acoustic attenuation, and solid glass spheres to increase backscattering. The frequency dependence of ultrasound attenuation was well described with a power law over the measured range of 3-10 MHz. With the addition of paraffin wax in concentrations of 0 to 8 w/w%, attenuation varied from 0.72 to 2.91 dB cm-1 at 3 MHz and from 6.84 to 26.63 dB cm-1 at 10 MHz. With solid glass sphere concentrations in the range of 0.025-0.9 w/w%, acoustic backscattering consistent with a wide range of ultrasonic appearances was achieved. Native gel wax maintained its integrity during compressive deformations up to 60%; its Young’s modulus was 17.4  ±  1.4 kPa. The gel wax with additives was shaped by melting and pouring it into 3D printed moulds. Three different phantoms were constructed: a nerve and vessel phantom for peripheral nerve blocks, a heart atrium phantom, and a placental phantom for minimally-invasive fetal interventions. In the first, nerves and vessels were represented as hyperechoic and hypoechoic tubular structures, respectively, in a homogeneous background. The second phantom comprised atria derived from an MRI scan of a patient with an intervening septum and adjoining vena cavae. The third comprised the chorionic surface of a placenta with superficial fetal vessels derived from an image of a post-partum human placenta. Gel wax is a material with widely tuneable ultrasound properties and mechanical characteristics that are well suited for creating patient-specific ultrasound phantoms in several clinical disciplines.

  8. Measurement of flow velocity fields in small vessel-mimic phantoms and vessels of small animals using micro ultrasonic particle image velocimetry (micro-EPIV).

    Science.gov (United States)

    Qian, Ming; Niu, Lili; Wang, Yanping; Jiang, Bo; Jin, Qiaofeng; Jiang, Chunxiang; Zheng, Hairong

    2010-10-21

    Determining a multidimensional velocity field within microscale opaque fluid flows is needed in areas such as microfluidic devices, biofluid mechanics and hemodynamics research in animal studies. The ultrasonic particle image velocimetry (EchoPIV) technique is appropriate for measuring opaque flows by taking advantage of PIV and B-mode ultrasound contrast imaging. However, the use of clinical ultrasound systems for imaging flows in small structures or animals has limitations associated with spatial resolution. This paper reports on the development of a high-resolution EchoPIV technique (termed as micro-EPIV) and its application in measuring flows in small vessel-mimic phantoms and vessels of small animals. Phantom experiments demonstrate the validity of the technique, providing velocity estimates within 4.1% of the analytically derived values with regard to the flows in a small straight vessel-mimic phantom, and velocity estimates within 5.9% of the computationally simulated values with regard to the flows in a small stenotic vessel-mimic phantom. Animal studies concerning arterial and venous flows of living rats and rabbits show that the micro-EPIV-measured peak velocities within several cardiac cycles are about 25% below the values measured by the ultrasonic spectral Doppler technique. The micro-EPIV technique is able to effectively measure the flow fields within microscale opaque fluid flows.

  9. Measurement of flow velocity fields in small vessel-mimic phantoms and vessels of small animals using micro ultrasonic particle image velocimetry (micro-EPIV)

    International Nuclear Information System (INIS)

    Qian Ming; Niu Lili; Jiang Bo; Jin Qiaofeng; Jiang Chunxiang; Zheng Hairong; Wang Yanping

    2010-01-01

    Determining a multidimensional velocity field within microscale opaque fluid flows is needed in areas such as microfluidic devices, biofluid mechanics and hemodynamics research in animal studies. The ultrasonic particle image velocimetry (EchoPIV) technique is appropriate for measuring opaque flows by taking advantage of PIV and B-mode ultrasound contrast imaging. However, the use of clinical ultrasound systems for imaging flows in small structures or animals has limitations associated with spatial resolution. This paper reports on the development of a high-resolution EchoPIV technique (termed as micro-EPIV) and its application in measuring flows in small vessel-mimic phantoms and vessels of small animals. Phantom experiments demonstrate the validity of the technique, providing velocity estimates within 4.1% of the analytically derived values with regard to the flows in a small straight vessel-mimic phantom, and velocity estimates within 5.9% of the computationally simulated values with regard to the flows in a small stenotic vessel-mimic phantom. Animal studies concerning arterial and venous flows of living rats and rabbits show that the micro-EPIV-measured peak velocities within several cardiac cycles are about 25% below the values measured by the ultrasonic spectral Doppler technique. The micro-EPIV technique is able to effectively measure the flow fields within microscale opaque fluid flows.

  10. Technical Note: A new phantom design for routine testing of Doppler ultrasound.

    Science.gov (United States)

    Grice, J V; Pickens, D R; Price, R R

    2016-07-01

    The objective of this project is to demonstrate the principle and operation for a simple, inexpensive, and highly portable Doppler ultrasound quality assurance (QA) phantom intended for routine QA testing. A prototype phantom has been designed, fabricated, and evaluated. The phantom described here is powered by gravity alone, requires no external equipment for operation, and produces a stable fluid velocity useful for quality assurance. Many commercially available Doppler ultrasound testing systems can suffer from issues such as a lengthy setup, prohibitive cost, nonportable size, or difficulty in use. This new phantom design aims to address some of these problems and create a phantom appropriate for assessing Doppler ultrasound stability. The phantom was fabricated using a 3D printer. The basic design of the phantom is to provide gravity-powered flow of a Doppler fluid between two reservoirs. The printed components were connected with latex tubing and then seated in a tissue mimicking gel. Spectral Doppler waveforms were sampled to evaluate variations in the data, and the phantom was evaluated using high frame rate video to find an alternate measure of mean fluid velocity flowing in the phantom. The current system design maintains stable flow from one reservoir to the other for approximately 7 s. Color Doppler imaging of the phantom was found to be qualitatively consistent with laminar flow. Using pulsed spectral Doppler, the average fluid velocity from a sample volume approximately centered in the synthetic vessel was measured to be 56 cm/s with a standard deviation of 3.2 cm/s across 118 measurements. An independent measure of the average fluid velocity was measured to be 51.9 cm/s with a standard deviation of 0.7 cm/s over 4 measurements. The developed phantom provides stable fluid flow useful for frequent clinical Doppler ultrasound testing and attempts to address several obstacles facing Doppler phantom testing. Such an ultrasound phantom can make routine

  11. Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging

    International Nuclear Information System (INIS)

    Surry, K J M; Austin, H J B; Fenster, A; Peters, T M

    2004-01-01

    Poly(vinyl alcohol) cryogel, PVA-C, is presented as a tissue-mimicking material, suitable for application in magnetic resonance (MR) imaging and ultrasound imaging. A 10% by weight poly(vinyl alcohol) in water solution was used to form PVA-C, which is solidified through a freeze-thaw process. The number of freeze-thaw cycles affects the properties of the material. The ultrasound and MR imaging characteristics were investigated using cylindrical samples of PVA-C. The speed of sound was found to range from 1520 to 1540 m s -1 , and the attenuation coefficients were in the range of 0.075-0.28 dB (cm MHz) -1 . T1 and T2 relaxation values were found to be 718-1034 ms and 108-175 ms, respectively. We also present applications of this material in an anthropomorphic brain phantom, a multi-volume stenosed vessel phantom and breast biopsy phantoms. Some suggestions are made for how best to handle this material in the phantom design and development process

  12. Comparison of a GPS needle-tracking system, multiplanar imaging and 2D imaging for real-time ultrasound-guided epidural anaesthesia: A randomized, comparative, observer-blinded study on phantoms.

    Science.gov (United States)

    Menacé, Cécilia; Choquet, Olivier; Abbal, Bertrand; Bringuier, Sophie; Capdevila, Xavier

    2017-04-01

    The real-time ultrasound-guided paramedian sagittal oblique approach for neuraxial blockade is technically demanding. Innovative technologies have been developed to improve nerve identification and the accuracy of needle placement. The aim of this study was to evaluate three types of ultrasound scans during ultrasound-guided epidural lumbar punctures in a spine phantom. Eleven sets of 20 ultrasound-guided epidural punctures were performed with 2D, GPS, and multiplanar ultrasound machines (660 punctures) on a spine phantom using an in-plane approach. For all punctures, execution time, number of attempts, bone contacts, and needle redirections were noted by an independent physician. Operator comfort and visibility of the needle (tip and shaft) were measured using a numerical scale. The use of GPS significantly decreased the number of punctures, needle repositionings, and bone contacts. Comfort of the physician was also significantly improved with the GPS system compared with the 2D and multiplanar systems. With the multiplanar system, the procedure was not facilitated and execution time was longer compared with 2D imaging after Bonferroni correction but interaction between the type of ultrasound system and mean execution time was not significant in a linear mixed model. There were no significant differences regarding needle tip and shaft visibility between the systems. Multiplanar and GPS needle-tracking systems do not reduce execution time compared with 2D imaging using a real-time ultrasound-guided paramedian sagittal oblique approach in spine phantoms. The GPS needle-tracking system can improve performance in terms of operator comfort, the number of attempts, needle redirections and bone contacts. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  13. CT and Ultrasound Guided Stereotactic High Intensity Focused Ultrasound (HIFU)

    Science.gov (United States)

    Wood, Bradford J.; Yanof, J.; Frenkel, V.; Viswanathan, A.; Dromi, S.; Oh, K.; Kruecker, J.; Bauer, C.; Seip, R.; Kam, A.; Li, K. C. P.

    2006-05-01

    To demonstrate the feasibility of CT and B-mode Ultrasound (US) targeted HIFU, a prototype coaxial focused ultrasound transducer was registered and integrated to a CT scanner. CT and diagnostic ultrasound were used for HIFU targeting and monitoring, with the goals of both thermal ablation and non-thermal enhanced drug delivery. A 1 megahertz coaxial ultrasound transducer was custom fabricated and attached to a passive position-sensing arm and an active six degree-of-freedom robotic arm via a CT stereotactic frame. The outer therapeutic transducer with a 10 cm fixed focal zone was coaxially mounted to an inner diagnostic US transducer (2-4 megahertz, Philips Medical Systems). This coaxial US transducer was connected to a modified commercial focused ultrasound generator (Focus Surgery, Indianapolis, IN) with a maximum total acoustic power of 100 watts. This pre-clinical paradigm was tested for ability to heat tissue in phantoms with monitoring and navigation from CT and live US. The feasibility of navigation via image fusion of CT with other modalities such as PET and MRI was demonstrated. Heated water phantoms were tested for correlation between CT numbers and temperature (for ablation monitoring). The prototype transducer and integrated CT/US imaging system enabled simultaneous multimodality imaging and therapy. Pre-clinical phantom models validated the treatment paradigm and demonstrated integrated multimodality guidance and treatment monitoring. Temperature changes during phantom cooling corresponded to CT number changes. Contrast enhanced or non-enhanced CT numbers may potentially be used to monitor thermal ablation with HIFU. Integrated CT, diagnostic US, and therapeutic focused ultrasound bridges a gap between diagnosis and therapy. Preliminary results show that the multimodality system may represent a relatively inexpensive, accessible, and simple method of both targeting and monitoring HIFU effects. Small animal pre-clinical models may be translated to large

  14. Comparison of a novel real-time SonixGPS needle-tracking ultrasound technique with traditional ultrasound for vascular access in a phantom gel model.

    Science.gov (United States)

    Kopac, Daniel S; Chen, Jerry; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    Ultrasound-guided percutaneous vascular access for endovascular procedures is well established in surgical practice. Despite this, rates of complications from venous and arterial access procedures remain a significant cause of morbidity. We hypothesized that the use of a new technique of vascular access using an ultrasound with a novel needle-guidance positioning system (GPS) would lead to improved success rates of vascular puncture for both in-plane and out-of-plane techniques compared with traditional ultrasound. A prospective, randomized crossover study of medical students from all years of medical school was conducted using a phantom gel model. Each medical student performed three ultrasound-guided punctures with each of the four modalities (in-plane no GPS, in-plane with GPS, out-of-plane no GPS, out-of-plane with GPS) for a total of 12 attempts. The success or failure was judged by the ability to aspirate a simulated blood solution from the model. The time to successful puncture was also recorded. A poststudy validated NASA Task Load Index workload questionnaire was conducted to assess the student's perceptions of the two different techniques. A total of 30 students completed the study. There was no significant difference seen in the mean times of vascular access for each of the modalities. Higher success rates for vascular access using the GPS for both the in-plane (94% vs 91%) and the out-of-plane (86% vs 70%) views were observed; however, this was not statistically significant. The students perceived the mental demand (median 12.0 vs 14.00; P = .035) and effort to be lower (mean 11.25 vs 14.00; P = .044) as well as the performance to be higher (mean 15.50 vs 14.00; P = .041) for the GPS vs the traditional ultrasound-guided technique. Students also perceived their ability to access vessels increased with the aid of the GPS (7.00 vs 6.50; P = .007). The majority of students expressed a preference for GPS (26/30, 87%) as opposed to the traditional counterpart

  15. An Inexpensive and Easy Ultrasound Phantom: A Novel Use for SPAM.

    Science.gov (United States)

    Nolting, Laura; Hunt, Patrick; Cook, Thomas; Douglas, Barton

    2016-04-01

    Ultrasound models, commonly referred to as "phantoms," are simulation tools for ultrasound education. Commercially produced phantoms are available, but there are "homemade" alternatives such as raw poultry and gelatin molds. Precooked, processed meat, better known as SPAM (Hormel Foods Corporation, Austin, MN), can be used as an ultrasound phantom to teach several ultrasound applications. It is a versatile, hygienic, and easily manipulated medium that does not require refrigeration or preparatory work and can be easily discarded at the end of use. © 2016 by the American Institute of Ultrasound in Medicine.

  16. Realistic deformable 3D numeric phantom for transcutaneous ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Fernando Mitsuyama; Moraes, Matheus Cardoso; Furuie, Sergio Shiguemi, E-mail: fernando.okara@gmail.com [Universidade de Sao Paulo (USP), SP (Brazil). Escola de Engenharia

    2017-01-15

    Introduction: Numerical phantoms are important tools to design, calibrate and evaluate several methods in various image-processing applications, such as echocardiography and mammography. We present a framework for creating ultrasound numerical deformable phantoms based on Finite Element Method (FEM), Linear Isomorphism and Field II. The proposed method considers that the scatterers map is a property of the tissue; therefore, the scatterers should move according to the tissue strain. Methods: First, a volume representing the target tissue is loaded. Second, parameter values, such as Young's Modulus, scatterers density, attenuation and scattering amplitudes are inserted for each different regions of the phantom. Then, other parameters related to the ultrasound equipment, such as ultrasound frequency and number of transducer elements, are also defined in order to perform the ultrasound acquisition using Field II. Third, the size and position of the transducer and the pressures that are applied against the tissue are defined. Subsequently, FEM is executed and deformation is computed. Next, 3D linear isomorphism is performed to displace the scatterers according to the deformation. Finally, Field II is carried out to generate the non-deformed and deformed ultrasound data. Results: The framework is evaluated by comparing strain values obtained the numerical simulation and from the physical phantom from CIRS. The mean difference between both phantoms is lesser than 10%. Conclusion: The acoustic and deformation outcomes are similar to those obtained using a physical phantom. This framework led to a tool, which is available online and free of charges for educational and research purposes. (author)

  17. Trapping of Embolic Particles in a Vessel Phantom by Cavitation-Enhanced Acoustic Streaming

    Science.gov (United States)

    Maxwell, Adam D.; Park, Simone; Vaughan, Benjamin L.; Cain, Charles A.; Grotberg, James B.; Xu, Zhen

    2014-01-01

    Cavitation clouds generated by short, high-amplitude, focused ultrasound pulses were previously observed to attract, trap, and erode thrombus fragments in a vessel phantom. This phenomenon may offer a noninvasive method to capture and eliminate embolic fragments flowing through the bloodstream during a cardiovascular intervention. In this article, the mechanism of embolus trapping was explored by particle image velocimetry (PIV). PIV was used to examine the fluid streaming patterns generated by ultrasound in a vessel phantom with and without crossflow of blood-mimicking fluid. Cavitation enhanced streaming, which generated fluid vortices adjacent to the focus. The focal streaming velocity, uf, was as high as 120 cm/s, while mean crossflow velocities, uc, were imposed up to 14 cm/s. When a solid particle 3-4 mm diameter was introduced into crossflow, it was trapped near the focus. Increasing uf promoted particle trapping while increasing uc promoted particle escape. The maximum crossflow Reynolds number at which particles could be trapped, Rec, was approximately linear with focal streaming number, Ref, i.e. Rec = 0.25Ref + 67.44 (R2=0.76) corresponding to dimensional velocities uc=0.084uf + 3.122 for 20 < uf < 120 cm/s. The fluidic pressure map was estimated from PIV and indicated a negative pressure gradient towards the focus, trapping the embolus near this location. PMID:25109407

  18. Comparison of the development of performance skills in ultrasound-guided regional anesthesia simulations with different phantom models.

    Science.gov (United States)

    Liu, Yang; Glass, Nancy L; Glover, Chris D; Power, Robert W; Watcha, Mehernoor F

    2013-12-01

    Ultrasound-guided regional anesthesia (UGRA) skills are traditionally obtained by supervised performance on patients, but practice on phantom models improves success. Currently available models are expensive or use perishable products, for example, olive-in-chicken breasts (OCB). We constructed 2 inexpensive phantom (transparent and opaque) models with readily available nonperishable products and compared the process of learning UGRA skills by novice practitioners on these models with the OCB model. Three experts first established criteria for a satisfactory completion of the simulated UGRA task in the 3 models. Thirty-six novice trainees (simulations was accomplished. The number of errors, needle passes, and time for task completion per attempt progressively decreased in all 3 groups. However, failure to identify the target and to visualize the needle on the ultrasound image occurred more frequently with the OCB model. The time to complete simulator training was shortest with the transparent model, owing to shorter target identification times. However, trainees were less likely to agree strongly that this model was realistic for teaching UGRA skills. Training on inexpensive synthetic simulation models with no perishable products permits learning of UGRA skills by novices. The OCB model has disadvantages of containing potentially infective material, requires refrigeration, cannot be used after multiple needle punctures, and is associated with more failures during simulated UGRA. Direct visualization of the target in the transparent model allows the trainee to focus on needle insertion skills, but the opaque model may be more realistic for learning target identification skills required when UGRA is performed on real patients in the operating room.

  19. An ultrasound needle insertion guide in a porcine phantom model.

    Science.gov (United States)

    Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I

    2013-08-01

    We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  20. Trapping of embolic particles in a vessel phantom by cavitation-enhanced acoustic streaming

    International Nuclear Information System (INIS)

    Maxwell, Adam D; Park, Simone; Cain, Charles A; Grotberg, James B; Xu, Zhen; Vaughan, Benjamin L

    2014-01-01

    Cavitation clouds generated by short, high-amplitude, focused ultrasound pulses were previously observed to attract, trap, and erode thrombus fragments in a vessel phantom. This phenomenon may offer a noninvasive method to capture and eliminate embolic fragments flowing through the bloodstream during a cardiovascular intervention. In this article, the mechanism of embolus trapping was explored by particle image velocimetry (PIV). PIV was used to examine the fluid streaming patterns generated by ultrasound in a vessel phantom with and without crossflow of blood-mimicking fluid. Cavitation enhanced streaming, which generated fluid vortices adjacent to the focus. The focal streaming velocity, u f , was as high as 120 cm/s, while mean crossflow velocities, u c , were imposed up to 14 cm/s. When a solid particle 3–4 mm diameter was introduced into crossflow, it was trapped near the focus. Increasing u f promoted particle trapping while increasing u c promoted particle escape. The maximum crossflow Reynolds number at which particles could be trapped, Re c , was approximately linear with focal streaming number, Re f , i.e. Re c = 0.25Re f + 67.44 (R 2 = 0.76) corresponding to dimensional velocities u c = 0.084u f + 3.122 for 20 < u f  < 120 cm/s. The fluidic pressure map was estimated from PIV and indicated a negative pressure gradient towards the focus, trapping the embolus near this location. (paper)

  1. Design of a tracked ultrasound calibration phantom made of LEGO bricks

    Science.gov (United States)

    Walsh, Ryan; Soehl, Marie; Rankin, Adam; Lasso, Andras; Fichtinger, Gabor

    2014-03-01

    PURPOSE: Spatial calibration of tracked ultrasound systems is commonly performed using precisely fabricated phantoms. Machining or 3D printing has relatively high cost and not easily available. Moreover, the possibilities for modifying the phantoms are very limited. Our goal was to find a method to construct a calibration phantom from affordable, widely available components, which can be built in short time, can be easily modified, and provides comparable accuracy to the existing solutions. METHODS: We designed an N-wire calibration phantom made of LEGO® bricks. To affirm the phantom's reproducibility and build time, ten builds were done by first-time users. The phantoms were used for a tracked ultrasound calibration by an experienced user. The success of each user's build was determined by the lowest root mean square (RMS) wire reprojection error of three calibrations. The accuracy and variance of calibrations were evaluated for the calibrations produced for various tracked ultrasound probes. The proposed model was compared to two of the currently available phantom models for both electromagnetic and optical tracking. RESULTS: The phantom was successfully built by all ten first-time users in an average time of 18.8 minutes. It cost approximately $10 CAD for the required LEGO® bricks and averaged a 0.69mm of error in the calibration reproducibility for ultrasound calibrations. It is one third the cost of similar 3D printed phantoms and takes much less time to build. The proposed phantom's image reprojections were 0.13mm more erroneous than those of the highest performing current phantom model The average standard deviation of multiple 3D image reprojections differed by 0.05mm between the phantoms CONCLUSION: It was found that the phantom could be built in less time, was one third the cost, compared to similar 3D printed models. The proposed phantom was found to be capable of producing equivalent calibrations to 3D printed phantoms.

  2. Noncontact ultrasound imaging applied to cortical bone phantoms.

    Science.gov (United States)

    Bulman, J B; Ganezer, K S; Halcrow, P W; Neeson, Ian

    2012-06-01

    The purpose of this paper was to take the first steps toward applying noncontact ultrasound (NCU) to the tasks of monitoring osteoporosis and quantitative ultrasound imaging (QUS) of cortical bone. The authors also focused on the advantages of NCU, such as its lack of reliance on a technologist to apply transducers and a layer of acoustical coupling gel, the ability of the transducers to operate autonomously as specified by preprogrammed software, and the likely reduction in statistical and systematic errors associated with the variability in the pressure applied by the clinician to the transmitting transducer that NCU might provide. The authors also undertook this study in order to find additional applications of NCU beyond its past limited usage in assessing the severity of third degree burns. A noncontact ultrasound imaging system using a pair of specially designed broadband, 1.5 MHz noncontact piezoelectric transducers and cortical bone phantoms, were used to determine bone mineral density (BMD), speed of sound (SOS), integrated response (IR), and ultrasonic transmittance. Air gaps of greater than 3 cm, two transmission and two reflection paths, and a digital signal processor were also used in the collection of data from phantoms of nominal mass densities that varied from 1.17 to 2.25 g/cm(3) and in bone mineral density from 0 to 1.7 g/cm(3). Good correlations between known BMD and measured SOS, IR, and transmittance were obtained for all 17 phantoms, and methods for quantifying and minimizing sources of systematic errors were outlined. The BMD of the phantom sets extended through most of the in vivo range found in cortical bone. A total of 16-20 repeated measurements of the SOS, thickness, and IR for the phantom set that were conducted over a period of several months showed a small variation in the range of measurements of ±1%-2%. These NCU data were shown to be in agreement with similar results using contact ultrasound to be within 1%-2%. Transmittance

  3. Technical Note: Multipurpose CT, ultrasound, and MRI breast phantom for use in radiotherapy and minimally invasive interventions

    Energy Technology Data Exchange (ETDEWEB)

    Ruschin, Mark, E-mail: Mark.Ruschin@sunnybrook.ca; Chin, Lee; Ravi, Ananth; McCann, Claire [Department of Medical Physics, Sunnybrook Odette Cancer Centre, Toronto, Ontario M4N 3M5, Canada and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M4N 3M5 (Canada); Davidson, Sean R. H. [Techna Institute, University Health Network, Toronto, Ontario M5G 1P5 (Canada); Phounsy, William [Department of Physics, Ryerson University, Toronto, Ontario M5B 2K3 (Canada); Yoo, Tae Sun [Institute of Health Policy, University of Toronto, Toronto, Ontario M5T 3M6 (Canada); Pignol, Jean-Philippe [Department of Radiation Oncology, Erasmus MC Cancer Institute, 3075 EA Rotterdam (Netherlands)

    2016-05-15

    Purpose: To develop a multipurpose gel-based breast phantom consisting of a simulated tumor with realistic imaging properties in CT, ultrasound and MRI, or a postsurgical cavity on CT. Applications for the phantom include: deformable image registration (DIR) quality assurance (QA), autosegmentation validation, and localization testing and training for minimally invasive image-guided procedures such as those involving catheter or needle insertion. Methods: A thermoplastic mask of a typical breast patient lying supine was generated and then filled to make an array of phantoms. The background simulated breast tissue consisted of 32.4 g each of ballistic gelatin (BG) powder and Metamusil™ (MM) dissolved in 800 ml of water. Simulated tumors were added using the following recipe: 12 g of barium sulfate (1.4% v/v) plus 0.000 14 g copper sulfate plus 0.7 g of MM plus 7.2 g of BG all dissolved in 75 ml of water. The phantom was evaluated quantitatively in CT by comparing Hounsfield units (HUs) with actual breast tissue. For ultrasound and MRI, the phantoms were assessed based on subjective image quality and signal-difference to noise (SDNR) ratio, respectively. The stiffness of the phantom was evaluated based on ultrasound elastography measurements to yield an average Young’s modulus. In addition, subjective tactile assessment of phantom was performed under needle insertion. Results: The simulated breast tissue had a mean background value of 24 HU on CT imaging, which more closely resembles fibroglandular tissue (40 HU) as opposed to adipose (−100 HU). The tumor had a mean CT number of 45 HU, which yielded a qualitatively realistic image contrast relative to the background either as an intact tumor or postsurgical cavity. The tumor appeared qualitatively realistic on ultrasound images, exhibiting hypoechoic characteristics compared to background. On MRI, the tumor exhibited a SDNR of 3.7. The average Young’s modulus was computed to be 15.8 ± 0.7 kPa (1 SD

  4. A tissue phantom for visualization and measurement of ultrasound-induced cavitation damage.

    Science.gov (United States)

    Maxwell, Adam D; Wang, Tzu-Yin; Yuan, Lingqian; Duryea, Alexander P; Xu, Zhen; Cain, Charles A

    2010-12-01

    Many ultrasound studies involve the use of tissue-mimicking materials to research phenomena in vitro and predict in vivo bioeffects. We have developed a tissue phantom to study cavitation-induced damage to tissue. The phantom consists of red blood cells suspended in an agarose hydrogel. The acoustic and mechanical properties of the gel phantom were found to be similar to soft tissue properties. The phantom's response to cavitation was evaluated using histotripsy. Histotripsy causes breakdown of tissue structures by the generation of controlled cavitation using short, focused, high-intensity ultrasound pulses. Histotripsy lesions were generated in the phantom and kidney tissue using a spherically focused 1-MHz transducer generating 15 cycle pulses, at a pulse repetition frequency of 100 Hz with a peak negative pressure of 14 MPa. Damage appeared clearly as increased optical transparency of the phantom due to rupture of individual red blood cells. The morphology of lesions generated in the phantom was very similar to that generated in kidney tissue at both macroscopic and cellular levels. Additionally, lesions in the phantom could be visualized as hypoechoic regions on a B-mode ultrasound image, similar to histotripsy lesions in tissue. High-speed imaging of the optically transparent phantom was used to show that damage coincides with the presence of cavitation. These results indicate that the phantom can accurately mimic the response of soft tissue to cavitation and provide a useful tool for studying damage induced by acoustic cavitation. Copyright © 2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. Fabrication of subcutaneous veins phantom for vessel visualization system

    Science.gov (United States)

    Cheng, Kai; Narita, Kazuyuki; Morita, Yusuke; Nakamachi, Eiji; Honda, Norihiro; Awazu, Kunio

    2013-09-01

    The technique of subcutaneous veins imaging by using NIR (Near Infrared Radiation) is widely used in medical applications, such as the intravenous injection and the blood sampling. In the previous study, an automatic 3D blood vessel search and automatic blood sampling system was newly developed. In order to validate this NIR imaging system, we adopted the subcutaneous vein in the human arm and its artificial phantom, which imitate the human fat and blood vessel. The human skin and subcutaneous vein is characterized as the uncertainty object, which has the individual specificity, non-accurate depth information, non-steady state and hardly to be fixed in the examination apparatus. On the other hand, the conventional phantom was quite distinct from the human's characteristics, such as the non-multilayer structure, disagreement of optical property. In this study, we develop a multilayer phantom, which is quite similar with human skin, for improvement of NIR detection system evaluation. The phantom consists of three layers, such as the epidermis layer, the dermis layer and the subcutaneous fat layer. In subcutaneous fat layer, we built a blood vessel. We use the intralipid to imitate the optical scattering characteristics of human skin, and the hemoglobin and melanin for the optical absorption characteristics. In this study, we did two subjects. First, we decide the fabrication process of the phantom. Second, we compared newly developed phantoms with human skin by using our NIR detecting system, and confirm the availability of these phantoms.

  6. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  7. Gelatin model for training ultrasound-guided puncture

    Directory of Open Access Journals (Sweden)

    Alexandre Campos Moraes Amato

    2015-09-01

    Full Text Available BACKGROUND: It is indispensable that members of the medical profession receive the technical training needed to enable them to rapidly obtain effective vascular access. Training procedures should be used judiciously to familiarize students with the technique. However, existing models are expensive or ineffective, and models need to be developed that are similar to what will be encountered in real patients.OBJECTIVES: To demonstrate creation and application of a gelatin model for training ultrasound-guided puncture.METHOS: The model was made using a mixture of colorless gelatin and water in a transparent plastic receptacle with two pairs of orifices of different diameters, through which two plastic tubes were inserted, to simulate blood vessels.RESULTS: The model was a close approximation to the real medical procedure in several aspects, since gelatin has a similar consistency to human tissues, providing a more faithful reproduction of the tactile sensation at the moment when the needle reaches the interior of a vessel and its contents are aspirated.CONCLUSIONS: The method proposed here can be used to easily construct a low-cost model using everyday materials that is suitable for large-scale training of ultrasound-guided puncture.

  8. Creation of a High-fidelity, Low-cost Pediatric Skull Fracture Ultrasound Phantom.

    Science.gov (United States)

    Soucy, Zachary P; Mills, Lisa; Rose, John S; Kelley, Kenneth; Ramirez, Francisco; Kuppermann, Nathan

    2015-08-01

    Over the past decade, point-of-care ultrasound has become a common tool used for both procedures and diagnosis. Developing high-fidelity phantoms is critical for training in new and novel point-of-care ultrasound applications. Detecting skull fractures on ultrasound imaging in the younger-than-2-year-old patient is an emerging area of point-of-care ultrasound research. Identifying a skull fracture on ultrasound imaging in this age group requires knowledge of the appearance and location of sutures to distinguish them from fractures. There are currently no commercially available pediatric skull fracture models. We outline a novel approach to building a cost-effective, simple, high-fidelity pediatric skull fracture phantom to meet a unique training requirement. © 2015 by the American Institute of Ultrasound in Medicine.

  9. Line fiducial material and thickness considerations for ultrasound calibration

    Science.gov (United States)

    Ameri, Golafsoun; McLeod, A. J.; Baxter, John S. H.; Chen, Elvis C. S.; Peters, Terry M.

    2015-03-01

    Ultrasound calibration is a necessary procedure in many image-guided interventions, relating the position of tools and anatomical structures in the ultrasound image to a common coordinate system. This is a necessary component of augmented reality environments in image-guided interventions as it allows for a 3D visualization where other surgical tools outside the imaging plane can be found. Accuracy of ultrasound calibration fundamentally affects the total accuracy of this interventional guidance system. Many ultrasound calibration procedures have been proposed based on a variety of phantom materials and geometries. These differences lead to differences in representation of the phantom on the ultrasound image which subsequently affect the ability to accurately and automatically segment the phantom. For example, taut wires are commonly used as line fiducials in ultrasound calibration. However, at large depths or oblique angles, the fiducials appear blurred and smeared in ultrasound images making it hard to localize their cross-section with the ultrasound image plane. Intuitively, larger diameter phantoms with lower echogenicity are more accurately segmented in ultrasound images in comparison to highly reflective thin phantoms. In this work, an evaluation of a variety of calibration phantoms with different geometrical and material properties for the phantomless calibration procedure was performed. The phantoms used in this study include braided wire, plastic straws, and polyvinyl alcohol cryogel tubes with different diameters. Conventional B-mode and synthetic aperture images of the phantoms at different positions were obtained. The phantoms were automatically segmented from the ultrasound images using an ellipse fitting algorithm, the centroid of which is subsequently used as a fiducial for calibration. Calibration accuracy was evaluated for these procedures based on the leave-one-out target registration error. It was shown that larger diameter phantoms with lower

  10. Automatic Segmentation of Vessels in In-Vivo Ultrasound Scans

    DEFF Research Database (Denmark)

    Tamimi-Sarnikowski, Philip; Brink-Kjær, Andreas; Moshavegh, Ramin

    2017-01-01

    presents a fully automatic segmentation algorithm, for robustly segmenting the vessel lumen in longitudinal B-mode ultrasound images. The automatic segmentation is performed using a combination of B-mode and power Doppler images. The proposed algorithm includes a series of preprocessing steps, and performs......Ultrasound has become highly popular to monitor atherosclerosis, by scanning the carotid artery. The screening involves measuring the thickness of the vessel wall and diameter of the lumen. An automatic segmentation of the vessel lumen, can enable the determination of lumen diameter. This paper...... a vessel segmentation by use of the marker-controlled watershed transform. The ultrasound images used in the study were acquired using the bk3000 ultrasound scanner (BK Ultrasound, Herlev, Denmark) with two transducers ”8L2 Linear” and ”10L2w Wide Linear” (BK Ultrasound, Herlev, Denmark). The algorithm...

  11. Ultrasound-guided approach for axillary brachial plexus, femoral nerve, and sciatic nerve blocks in dogs.

    Science.gov (United States)

    Campoy, Luis; Bezuidenhout, Abraham J; Gleed, Robin D; Martin-Flores, Manuel; Raw, Robert M; Santare, Carrie L; Jay, Ariane R; Wang, Annie L

    2010-03-01

    To describe an ultrasound-guided technique and the anatomical basis for three clinically useful nerve blocks in dogs. Prospective experimental trial. Four hound-cross dogs aged 2 +/- 0 years (mean +/- SD) weighing 30 +/- 5 kg and four Beagles aged 2 +/- 0 years and weighing 8.5 +/- 0.5 kg. Axillary brachial plexus, femoral, and sciatic combined ultrasound/electrolocation-guided nerve blocks were performed sequentially and bilaterally using a lidocaine solution mixed with methylene blue. Sciatic nerve blocks were not performed in the hounds. After the blocks, the dogs were euthanatized and each relevant site dissected. Axillary brachial plexus block Landmark blood vessels and the roots of the brachial plexus were identified by ultrasound in all eight dogs. Anatomical examination confirmed the relationship between the four ventral nerve roots (C6, C7, C8, and T1) and the axillary vessels. Three roots (C7, C8, and T1) were adequately stained bilaterally in all dogs. Femoral nerve block Landmark blood vessels (femoral artery and femoral vein), the femoral and saphenous nerves and the medial portion of the rectus femoris muscle were identified by ultrasound in all dogs. Anatomical examination confirmed the relationship between the femoral vessels, femoral nerve, and the rectus femoris muscle. The femoral nerves were adequately stained bilaterally in all dogs. Sciatic nerve block. Ultrasound landmarks (semimembranosus muscle, the fascia of the biceps femoris muscle and the sciatic nerve) could be identified in all of the dogs. In the four Beagles, anatomical examination confirmed the relationship between the biceps femoris muscle, the semimembranosus muscle, and the sciatic nerve. In the Beagles, all but one of the sciatic nerves were stained adequately. Ultrasound-guided needle insertion is an accurate method for depositing local anesthetic for axillary brachial plexus, femoral, and sciatic nerve blocks.

  12. Design and application of model for training ultrasound-guided vascular cannulation in pediatric patients.

    Science.gov (United States)

    Pérez-Quevedo, O; López-Álvarez, J M; Limiñana-Cañal, J M; Loro-Ferrer, J F

    2016-01-01

    Central vascular cannulation is not a risk-free procedure, especially in pediatric patients. Newborn and infants are small and low-weighted, their vascular structures have high mobility because of tissue laxity and their vessels are superficial and with small diameter. These characteristics, together with the natural anatomical variability and poor collaboration of small children, make this technique more difficult to apply. Therefore, ultrasound imaging is increasingly being used to locate vessels and guide vascular access in this population. (a) To present a model that simulates the vascular system for training ultrasound-guided vascular access in pediatrics patients; (b) to ultrasound-guided vascular cannulation in the model. The model consisted of two components: (a) muscular component: avian muscle, (b) vascular component: elastic tube-like structure filled with fluid. 864 ecoguided punctures was realized in the model at different vessel depth and gauge measures were simulated, for two medical operators with different degree of experience. The average depth and diameter of vessel cannulated were 1.16 (0.42)cm and 0.43 (0.1)cm, respectively. The average number of attempts was of 1.22 (0.62). The percentage of visualization of the needle was 74%. The most frequent maneuver used for the correct location, was the modification of the angle of the needle and the relocation of the guidewire in 24% of the cases. The average time for the correct cannulations was 41 (35.8)s. The more frequent complications were the vascular perforation (11.9%) and the correct vascular puncture without possibility of introducing the guidewire (1.2%). The rate of success was 96%. The model simulates the anatomy (vascular and muscular structures) of a pediatric patient. It is cheap models, easily reproducible and a useful tool for training in ultrasound-guided puncture and cannulation. Copyright © 2015 Elsevier España, S.L.U. y SEMICYUC. All rights reserved.

  13. Comparative imaging study in ultrasound, MRI, CT, and DSA using a multimodality renal artery phantom

    Energy Technology Data Exchange (ETDEWEB)

    King, Deirdre M.; Fagan, Andrew J.; Moran, Carmel M.; Browne, Jacinta E. [Medical Ultrasound Physics and Technology Group, School of Physics, Dublin Institute of Technology, Dublin 8 (Ireland); Centre for Advanced Medical Imaging (CAMI), St James' s Hospital, Dublin 8 (Ireland); Department of Medical Physics, University of Edinburgh, Edinburgh EH16 4TJ (United Kingdom); Medical Ultrasound Physics and Technology Group, School of Physics, Dublin Institute of Technology, Dublin 8 (Ireland)

    2011-02-15

    Purpose: A range of anatomically realistic multimodality renal artery phantoms consisting of vessels with varying degrees of stenosis was developed and evaluated using four imaging techniques currently used to detect renal artery stenosis (RAS). The spatial resolution required to visualize vascular geometry and the velocity detection performance required to adequately characterize blood flow in patients suffering from RAS are currently ill-defined, with the result that no one imaging modality has emerged as a gold standard technique for screening for this disease. Methods: The phantoms, which contained a range of stenosis values (0%, 30%, 50%, 70%, and 85%), were designed for use with ultrasound, magnetic resonance imaging, x-ray computed tomography, and x-ray digital subtraction angiography. The construction materials used were optimized with respect to their ultrasonic speed of sound and attenuation coefficient, MR relaxometry (T{sub 1},T{sub 2}) properties, and Hounsfield number/x-ray attenuation coefficient, with a design capable of tolerating high-pressure pulsatile flow. Fiducial targets, incorporated into the phantoms to allow for registration of images among modalities, were chosen to minimize geometric distortions. Results: High quality distortion-free images of the phantoms with good contrast between vessel lumen, fiducial markers, and background tissue to visualize all stenoses were obtained with each modality. Quantitative assessments of the grade of stenosis revealed significant discrepancies between modalities, with each underestimating the stenosis severity for the higher-stenosed phantoms (70% and 85%) by up to 14%, with the greatest discrepancy attributable to DSA. Conclusions: The design and construction of a range of anatomically realistic renal artery phantoms containing varying degrees of stenosis is described. Images obtained using the main four diagnostic techniques used to detect RAS were free from artifacts and exhibited adequate contrast

  14. Comparative imaging study in ultrasound, MRI, CT, and DSA using a multimodality renal artery phantom

    International Nuclear Information System (INIS)

    King, Deirdre M.; Fagan, Andrew J.; Moran, Carmel M.; Browne, Jacinta E.

    2011-01-01

    Purpose: A range of anatomically realistic multimodality renal artery phantoms consisting of vessels with varying degrees of stenosis was developed and evaluated using four imaging techniques currently used to detect renal artery stenosis (RAS). The spatial resolution required to visualize vascular geometry and the velocity detection performance required to adequately characterize blood flow in patients suffering from RAS are currently ill-defined, with the result that no one imaging modality has emerged as a gold standard technique for screening for this disease. Methods: The phantoms, which contained a range of stenosis values (0%, 30%, 50%, 70%, and 85%), were designed for use with ultrasound, magnetic resonance imaging, x-ray computed tomography, and x-ray digital subtraction angiography. The construction materials used were optimized with respect to their ultrasonic speed of sound and attenuation coefficient, MR relaxometry (T 1 ,T 2 ) properties, and Hounsfield number/x-ray attenuation coefficient, with a design capable of tolerating high-pressure pulsatile flow. Fiducial targets, incorporated into the phantoms to allow for registration of images among modalities, were chosen to minimize geometric distortions. Results: High quality distortion-free images of the phantoms with good contrast between vessel lumen, fiducial markers, and background tissue to visualize all stenoses were obtained with each modality. Quantitative assessments of the grade of stenosis revealed significant discrepancies between modalities, with each underestimating the stenosis severity for the higher-stenosed phantoms (70% and 85%) by up to 14%, with the greatest discrepancy attributable to DSA. Conclusions: The design and construction of a range of anatomically realistic renal artery phantoms containing varying degrees of stenosis is described. Images obtained using the main four diagnostic techniques used to detect RAS were free from artifacts and exhibited adequate contrast to allow

  15. Tracked ultrasound calibration studies with a phantom made of LEGO bricks

    Science.gov (United States)

    Soehl, Marie; Walsh, Ryan; Rankin, Adam; Lasso, Andras; Fichtinger, Gabor

    2014-03-01

    In this study, spatial calibration of tracked ultrasound was compared by using a calibration phantom made of LEGO® bricks and two 3-D printed N-wire phantoms. METHODS: The accuracy and variance of calibrations were compared under a variety of operating conditions. Twenty trials were performed using an electromagnetic tracking device with a linear probe and three trials were performed using varied probes, varied tracking devices and the three aforementioned phantoms. The accuracy and variance of spatial calibrations found through the standard deviation and error of the 3-D image reprojection were used to compare the calibrations produced from the phantoms. RESULTS: This study found no significant difference between the measured variables of the calibrations. The average standard deviation of multiple 3-D image reprojections with the highest performing printed phantom and those from the phantom made of LEGO® bricks differed by 0.05 mm and the error of the reprojections differed by 0.13 mm. CONCLUSION: Given that the phantom made of LEGO® bricks is significantly less expensive, more readily available, and more easily modified than precision-machined N-wire phantoms, it prompts to be a viable calibration tool especially for quick laboratory research and proof of concept implementations of tracked ultrasound navigation.

  16. Treatment planning for image-guided neuro-vascular interventions using patient-specific 3D printed phantoms

    Science.gov (United States)

    Russ, M.; O'Hara, R.; Setlur Nagesh, S. V.; Mokin, M.; Jimenez, C.; Siddiqui, A.; Bednarek, D.; Rudin, S.; Ionita, C.

    2015-03-01

    Minimally invasive endovascular image-guided interventions (EIGIs) are the preferred procedures for treatment of a wide range of vascular disorders. Despite benefits including reduced trauma and recovery time, EIGIs have their own challenges. Remote catheter actuation and challenging anatomical morphology may lead to erroneous endovascular device selections, delays or even complications such as vessel injury. EIGI planning using 3D phantoms would allow interventionists to become familiarized with the patient vessel anatomy by first performing the planned treatment on a phantom under standard operating protocols. In this study the optimal workflow to obtain such phantoms from 3D data for interventionist to practice on prior to an actual procedure was investigated. Patientspecific phantoms and phantoms presenting a wide range of challenging geometries were created. Computed Tomographic Angiography (CTA) data was uploaded into a Vitrea 3D station which allows segmentation and resulting stereo-lithographic files to be exported. The files were uploaded using processing software where preloaded vessel structures were included to create a closed-flow vasculature having structural support. The final file was printed, cleaned, connected to a flow loop and placed in an angiographic room for EIGI practice. Various Circle of Willis and cardiac arterial geometries were used. The phantoms were tested for ischemic stroke treatment, distal catheter navigation, aneurysm stenting and cardiac imaging under angiographic guidance. This method should allow for adjustments to treatment plans to be made before the patient is actually in the procedure room and enabling reduced risk of peri-operative complications or delays.

  17. Polyvinyl chloride plastisol breast phantoms for ultrasound imaging.

    Science.gov (United States)

    de Carvalho, Isabela Miller; De Matheo, Lucas Lobianco; Costa Júnior, José Francisco Silva; Borba, Cecília de Melo; von Krüger, Marco Antonio; Infantosi, Antonio Fernando Catelli; Pereira, Wagner Coelho de Albuquerque

    2016-08-01

    Ultrasonic phantoms are objects that mimic some features of biological tissues, allowing the study of their interactions with ultrasound (US). In the diagnostic-imaging field, breast phantoms are an important tool for testing performance and optimizing US systems, as well as for training medical professionals. This paper describes the design and manufacture of breast lesions by using polyvinyl chloride plastisol (PVCP) as the base material. Among the materials available for this study, PVCP was shown to be stable, durable, and easy to handle. Furthermore, it is a nontoxic, nonpolluting, and low-cost material. The breast's glandular tissue (image background) was simulated by adding graphite powder with a concentration of 1% to the base material. Mixing PVCP and graphite powder in differing concentrations allows one to simulate lesions with different echogenicity patterns (anechoic, hypoechoic, and hyperechoic). From this mixture, phantom materials were obtained with speed of sound varying from 1379.3 to 1397.9ms(-1) and an attenuation coefficient having values between 0.29 and 0.94dBcm(-1) for a frequency of 1MHz at 24°C. A single layer of carnauba wax was added to the lesion surface in order to evaluate its applicability for imaging. The images of the phantoms were acquired using commercial ultrasound equipment; a specialist rated the images, elaborating diagnoses representative of both benign and malignant lesions. The results indicated that it was possible to easily create a phantom by using low-cost materials, readily available in the market and stable at room temperature, as the basis of ultrasonic phantoms that reproduce the image characteristics of fatty breast tissue and typical lesions of the breast. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. A novel composite material specifically developed for ultrasound bone phantoms: cortical, trabecular and skull

    International Nuclear Information System (INIS)

    Wydra, A; Maev, R Gr

    2013-01-01

    In the various stages of developing diagnostic and therapeutic equipment, the use of phantoms can play a very important role in improving the process, help in implementation, testing and calibrations. Phantoms are especially useful in developing new applications and training new doctors in medical schools. However, devices that use different physical factors, such as MRI, Ultrasound, CT Scan, etc will require the phantom to be made of different physical properties. In this paper we introduce the properties of recently designed new materials for developing phantoms for ultrasonic human body investigation, which in today's market make up more than 30% in the world of phantoms. We developed a novel composite material which allows fabrication of various kinds of ultrasound bone phantoms to mimic most of the acoustical properties of human bones. In contrast to the ex vivo tissues, the proposed material can maintain the physical and acoustical properties unchanged for long periods of time; moreover, these properties can be custom designed and created to suit specific needs. As a result, we introduce three examples of ultrasound phantoms that we manufactured in our laboratory: cortical, trabecular and skull bone phantoms. The paper also presents the results of a comparison study between the acoustical and physical properties of actual human bones (reported in the referenced literatures) and the phantoms manufactured by us. (note)

  19. Development of an Anthropomorphic Breast Phantom for Combined PET, B-Mode Ultrasound and Elastographic Imaging

    OpenAIRE

    Dang, J; Lecoq, P; Tavernier, S; Lasaygues, P; Mensah, S; Zhang, D C; Auffray, E; Frisch, B; Varela, J; Wan, M X; Felix, N

    2011-01-01

    International audience; Combining the advantages of different imaging modalities leads to improved clinical results. For example, ultrasound provides good real-time structural information without any radiation and PET provides sensitive functional information. For the ongoing ClearPEM-Sonic project combining ultrasound and PET for breast imaging, we developed a dual-modality PET/Ultrasound (US) phantom. The phantom reproduces the acoustic and elastic properties of human breast tissue and allo...

  20. Shooting with sound: optimizing an affordable ballistic gelatin recipe in a graded ultrasound phantom education program.

    Science.gov (United States)

    Tanious, Shariff F; Cline, Jamie; Cavin, Jennifer; Davidson, Nathan; Coleman, J Keegan; Goodmurphy, Craig W

    2015-06-01

    The goal of this study was to investigate the durability and longevity of gelatin formulas for the production of staged ultrasound phantoms for education. Gelatin phantoms were prepared from Knox gelatin (Kraft Foods, Northfield, IL) and a standard 10%-by-mass ordinance gelatin solution. Phantoms were durability tested by compressing to a 2-cm depth until cracking was visible. Additionally, 16 containers with varying combinations of phenol, container type, and storage location were tested for longevity against desiccation and molding. Once formulation was determined, 4 stages of phantoms from novice to clinically relevant were poured, and clinicians with ultrasound training ranked them on a 7-point Likert scale based on task difficulty, phantom suitability, and fidelity. On durability testing, the ballistic gelatin outperformed the Knox gelatin by more than 200 compressions. On longevity testing, gelatin with a 0.5% phenol concentration stored with a lid and refrigeration lasted longest, whereas containers without a lid had desiccation within 1 month, and those without phenol became moldy within 6 weeks. Ballistic gelatin was more expensive when buying in small quantities but was 7.4% less expensive when buying in bulk. The staged phantoms were deemed suitable for training, but clinicians did not consistently rank the phantoms in the intended order of 1 to 4 (44%). Refrigerated and sealed ballistic gelatin with phenol was a cost-effective method for creating in-house staged ultrasound phantoms suitable for large-scale ultrasound educational training needs. Clinician ranking of phantoms may be influenced by current training methods that favor biological tissue scanning as easier. © 2015 by the American Institute of Ultrasound in Medicine.

  1. Development of an Anthropomorphic Breast Phantom for Combined PET, B-Mode Ultrasound and Elastographic Imaging

    CERN Document Server

    Dang, J; Tavernier, S; Lasaygues, P; Mensah, S; Zhang, D C; Auffray, E; Frisch, B; Varela, J; Wan, M X; Felix, N

    2011-01-01

    Combining the advantages of different imaging modalities leads to improved clinical results. For example, ultrasound provides good real-time structural information without any radiation and PET provides sensitive functional information. For the ongoing ClearPEM-Sonic project combining ultrasound and PET for breast imaging, we developed a dual-modality PET/Ultrasound (US) phantom. The phantom reproduces the acoustic and elastic properties of human breast tissue and allows labeling the different tissues in the phantom with different concentrations of FDG. The phantom was imaged with a whole-body PET/CT and with the Supersonic Imagine Aixplorer system. This system allows both B-mode US and shear wave elastographic imaging. US elastography is a new imaging method for displaying the tissue elasticity distribution. It was shown to be useful in breast imaging. We also tested the phantom with static elastography. A 6D magnetic positioning system allows fusing the images obtained with the two modalities. ClearPEM-Soni...

  2. Ultrasound guided supraclavicular block.

    LENUS (Irish Health Repository)

    Hanumanthaiah, Deepak

    2013-09-01

    Ultrasound guided regional anaesthesia is becoming increasingly popular. The supraclavicular block has been transformed by ultrasound guidance into a potentially safe superficial block. We reviewed the techniques of performing supraclavicular block with special focus on ultrasound guidance.

  3. Development of an Anthropomorphic Breast Phantom for Combined PET, B-Mode Ultrasound and Elastographic Imaging

    Science.gov (United States)

    Dang, Jun; Frisch, Benjamin; Lasaygues, Philippe; Zhang, Dachun; Tavernier, Stefaan; Felix, Nicolas; Lecoq, Paul; Auffray, Etiennette; Varela, Joao; Mensah, Serge; Wan, Mingxi

    2011-06-01

    Combining the advantages of different imaging modalities leads to improved clinical results. For example, ultrasound provides good real-time structural information without any radiation and PET provides sensitive functional information. For the ongoing ClearPEM-Sonic project combining ultrasound and PET for breast imaging, we developed a dual-modality PET/Ultrasound (US) phantom. The phantom reproduces the acoustic and elastic properties of human breast tissue and allows labeling the different tissues in the phantom with different concentrations of FDG. The phantom was imaged with a whole-body PET/CT and with the Supersonic Imagine Aixplorer system. This system allows both B-mode US and shear wave elastographic imaging. US elastography is a new imaging method for displaying the tissue elasticity distribution. It was shown to be useful in breast imaging. We also tested the phantom with static elastography. A 6D magnetic positioning system allows fusing the images obtained with the two modalities. ClearPEM-Sonic is a project of the Crystal Clear Collaboration and the European Centre for Research on Medical Imaging (CERIMED).

  4. Feasibility evaluation of 3D photoacoustic imaging of blood vessel structure using multiple wavelengths with a handheld probe

    Science.gov (United States)

    Uchimoto, Yo; Namita, Takeshi; Kondo, Kengo; Yamakawa, Makoto; Shiina, Tsuyoshi

    2018-02-01

    Photoacoustic imaging is anticipated for use in portraying blood vessel structures (e.g. neovascularization in inflamed regions). To reduce invasiveness and enhance ease handling, we developed a handheld photoacoustic imaging system using multiple wavelengths. The usefulness of the proposed system was investigated in phantom experiments and in vivo measurements. A silicon tube was embedded into chicken breast meat to simulate the blood vessel. The tube was filled with ovine blood. Then laser light was guided to the phantom surface by an optical fiber bundle close to the linear ultrasound probe. Photoacoustic images were obtained at 750-950 nm wavelengths. Strong photoacoustic signals from the boundary between blood and silicon tube are observed in these images. The shape of photoacoustic spectrum at the boundary resembles that of the HbO2 absorption spectrum at 750-920 nm. In photoacoustic images, similarity between photoacoustic spectrum and HbO2 absorption spectrum was evaluated by calculating the normalized correlation coefficient. Results show high correlation in regions of strong photoacoustic signals in photoacoustic images. These analyses demonstrate the feasibility of portraying blood vessel structures under practical conditions. To evaluate the feasibility of three-dimensional vascular imaging, in vivo experiments were conducted using three wavelengths. A right hand and ultrasound probe were set in degassed water. By scanning a probe, cross-sectional ultrasound and photoacoustic images were obtained at each location. Then, all ultrasound or photoacoustic images were piled up respectively. Then three-dimensional images were constructed. Resultant images portrayed blood vessel-like structures three-dimensionally. Furthermore, to distinguish blood vessels from other tissues (e.g. skin), distinguishing images of them were constructed by comparing photoacoustic signal intensity among three wavelengths. The resultant image portrayed blood vessels as

  5. The Role of Anthropomorphic Phantoms in Diagnostic Ultrasound Imaging for Disease Characterization

    International Nuclear Information System (INIS)

    Cannon, L. M.; King, D. M.; Browne, J. E.

    2009-01-01

    An anthropomorhic phantom is an object that can mimic a region of the human anatomy. Anthropomorphic phantoms have a variety of roles in diagnostic ultrasound. These roles include quality assurance testing of ultrasound machines, calibration and testing of new imaging techniques, training of sonographers, and--most importantly--use as a tool to obtain a better understanding of disease progression in the relevant anatomy. To be anthropomorphic a phantom must accurately mimic the body in terms of its ultrasonic and mechanical properties, as well as anatomically. The acoustic properties are speed of sound, attenuation, and backscatter. The mechanical properties are elasticity and density. Phantoms are constructed from tissue-mimicking materials (TMMs). TMMs are prepared from a variety of ingredients, such as gelatine, agar, safflower oil, and glass beads. These ingredients are then boiled and cooled under controlled conditions to produce a solid TMM. To determine if the TMM has the correct acoustic properties, acoustic measurements are performed using a scanning acoustic macroscope. Mechanical measurements are also performed to test the elasticity and density properties. TMMs with the correct properties are subsequently put through a series of moulding procedures to produce the anthropomorphic phantom.

  6. MR-guided focused ultrasound: a potentially disruptive technology.

    Science.gov (United States)

    Bradley, William G

    2009-07-01

    A disruptive technology is a technological innovation that overturns the existing dominant technologies in a market. Magnetic resonance (MR)-guided focused ultrasound (MRgFUS) is a noninvasive procedure based on the combination of real-time MR anatomic guidance, MR thermometry, and high-intensity focused ultrasound. Several hundred transducer elements become convergent at a point under MR guidance, leading to heating and coagulation necrosis. Outside the focal point, there is no significant heating. There is no need to break the skin for procedures in the body or to perform a craniotomy for procedures in the brain. This lack of invasiveness is what makes MRgFUS so disruptive compared with surgery. At present, MRgFUS has been used for the ablation of uterine fibroids, breast tumors, painful bony metastases, and liver tumors. In the brain, it has been used for the ablation of glioblastomas and for functional neurosurgery. Phantom and animal studies suggest future applications for prostate cancer and acute stroke treatment.

  7. Speckle tracking in a phantom and feature-based tracking in liver in the presence of respiratory motion using 4D ultrasound

    International Nuclear Information System (INIS)

    Harris, Emma J; Miller, Naomi R; Bamber, Jeffrey C; Symonds-Tayler, J Richard N; Evans, Philip M

    2010-01-01

    We have evaluated a 4D ultrasound-based motion tracking system developed for tracking of abdominal organs during therapy. Tracking accuracy and precision were determined using a tissue-mimicking phantom, by comparing tracked motion with known 3D sinusoidal motion. The feasibility of tracking 3D liver motion in vivo was evaluated by acquiring 4D ultrasound data from four healthy volunteers. For two of these volunteers, data were also acquired whilst simultaneously measuring breath flow using a spirometer. Hepatic blood vessels, tracked off-line using manual tracking, were used as a reference to assess, in vivo, two types of automated tracking algorithm: incremental (from one volume to the next) and non-incremental (from the first volume to each subsequent volume). For phantom-based experiments, accuracy and precision (RMS error and SD) were found to be 0.78 mm and 0.54 mm, respectively. For in vivo measurements, mean absolute distance and standard deviation of the difference between automatically and manually tracked displacements were less than 1.7 mm and 1 mm respectively in all directions (left-right, anterior-posterior and superior-inferior). In vivo non-incremental tracking gave the best agreement. In both phantom and in vivo experiments, tracking performance was poorest for the elevational component of 3D motion. Good agreement between automatically and manually tracked displacements indicates that 4D ultrasound-based motion tracking has potential for image guidance applications in therapy.

  8. Targeted Vessel Ablation for More Efficient Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Uterine Fibroids

    Energy Technology Data Exchange (ETDEWEB)

    Voogt, Marianne J., E-mail: m.voogt@umcutrecht.nl [University Medical Center Utrecht, Department of Radiology (Netherlands); Stralen, Marijn van [University Medical Center Utrecht, Image Sciences Institute (Netherlands); Ikink, Marlijne E. [University Medical Center Utrecht, Department of Radiology (Netherlands); Deckers, Roel; Vincken, Koen L.; Bartels, Lambertus W. [University Medical Center Utrecht, Image Sciences Institute (Netherlands); Mali, Willem P. Th. M.; Bosch, Maurice A. A. J. van den [University Medical Center Utrecht, Department of Radiology (Netherlands)

    2012-10-15

    Purpose: To report the first clinical experience with targeted vessel ablation during magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) treatment of symptomatic uterine fibroids. Methods: Pretreatment T1-weighted contrast-enhanced magnetic resonance angiography was used to create a detailed map of the uterine arteries and feeding branches to the fibroids. A three-dimensional overlay of the magnetic resonance angiography images was registered on 3D T2-weighted pretreatment imaging data. Treatment was focused primarily on locations where supplying vessels entered the fibroid. Patients were followed 6 months after treatment with a questionnaire to assess symptoms and quality of life (Uterine Fibroid Symptom and Quality of Life) and magnetic resonance imaging to quantify shrinkage of fibroid volumes. Results: In two patients, three fibroids were treated with targeted vessel ablation during MR-HIFU. The treatments resulted in almost total fibroid devascularization with nonperfused volume to total fibroid volume ratios of 84, 68, and 86%, respectively, of treated fibroids. The predicted ablated volumes during MR-HIFU in patients 1 and 2 were 45, 40, and 82 ml, respectively, while the nonperfused volumes determined immediately after treatment were 195, 92, and 190 ml respectively, which is 4.3 (patient 1) and 2.3 (patient 2) times higher than expected based on the thermal dose distribution. Fibroid-related symptoms reduced after treatment, and quality of life improved. Fibroid volume reduction ranged 31-59% at 6 months after treatment. Conclusion: Targeted vessel ablation during MR-HIFU allowed nearly complete fibroid ablation in both patients. This technique may enhance the use of MR-HIFU for fibroid treatment in clinical practice.

  9. Measurement of guided mode wavenumbers in soft tissue–bone mimicking phantoms using ultrasonic axial transmission

    International Nuclear Information System (INIS)

    Chen Jiangang; Su Zhongqing; Cheng Li; Foiret, Josquin; Minonzio, Jean-Gabriel; Talmant, Maryline; Laugier, Pascal

    2012-01-01

    Human soft tissue is an important factor that influences the assessment of human long bones using quantitative ultrasound techniques. To investigate such influence, a series of soft tissue–bone phantoms (a bone-mimicking plate coated with a layer of water, glycerol or silicon rubber) were ultrasonically investigated using a probe with multi-emitter and multi-receiver arrays in an axial transmission configuration. A singular value decomposition signal processing technique was applied to extract the frequency-dependent wavenumbers of several guided modes. The results indicate that the presence of a soft tissue-mimicking layer introduces additional guided modes predicted by a fluid waveguide model. The modes propagating in the bone-mimicking plate covered by the soft-tissue phantom are only slightly modified compared to their counterparts in the free bone-mimicking plate, and they are still predicted by an elastic transverse isotropic two-dimensional waveguide. Altogether these observations suggest that the soft tissue–bone phantoms can be modeled as two independent waveguides. Even in the presence of the overlying soft tissue-mimicking layer, the modes propagating in the bone-mimicking plate can still be extracted and identified. These results suggest that our approach can be applied for the purpose of the characterization of the material and structural properties of cortical bone. (paper)

  10. A novel ultrasound-guided shoulder arthroscopic surgery

    Science.gov (United States)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Chen, T.; Pichora, D.; Abolmaesumi, P.

    2006-03-01

    This paper presents a novel ultrasound-guided computer system for arthroscopic surgery of the shoulder joint. Intraoperatively, the system tracks and displays the surgical instruments, such as arthroscope and arthroscopic burrs, relative to the anatomy of the patient. The purpose of this system is to improve the surgeon's perception of the three-dimensional space within the anatomy of the patient in which the instruments are manipulated and to provide guidance towards the targeted anatomy. Pre-operatively, computed tomography images of the patient are acquired to construct virtual threedimensional surface models of the shoulder bone structure. Intra-operatively, live ultrasound images of pre-selected regions of the shoulder are captured using an ultrasound probe whose three-dimensional position is tracked by an optical camera. These images are used to register the surface model to the anatomy of the patient in the operating room. An initial alignment is obtained by matching at least three points manually selected on the model to their corresponding points identified on the ultrasound images. The registration is then improved with an iterative closest point or a sequential least squares estimation technique. In the present study the registration results of these techniques are compared. After the registration, surgical instruments are displayed relative to the surface model of the patient on a graphical screen visible to the surgeon. Results of laboratory experiments on a shoulder phantom indicate acceptable registration results and sufficiently fast overall system performance to be applicable in the operating room.

  11. The Role of Anthropomorphic Phantoms in Diagnostic Ultrasound Imaging for Disease Characterization (abstract)

    Science.gov (United States)

    Cannon, L. M.; King, D. M.; Browne, J. E.

    2009-04-01

    An anthropomorhic phantom is an object that can mimic a region of the human anatomy. Anthropomorphic phantoms have a variety of roles in diagnostic ultrasound. These roles include quality assurance testing of ultrasound machines, calibration and testing of new imaging techniques, training of sonographers, and-most importantly-use as a tool to obtain a better understanding of disease progression in the relevant anatomy. To be anthropomorphic a phantom must accurately mimic the body in terms of its ultrasonic and mechanical properties, as well as anatomically. The acoustic properties are speed of sound, attenuation, and backscatter. The mechanical properties are elasticity and density. Phantoms are constructed from tissue-mimicking materials (TMMs). TMMs are prepared from a variety of ingredients, such as gelatine, agar, safflower oil, and glass beads. These ingredients are then boiled and cooled under controlled conditions to produce a solid TMM. To determine if the TMM has the correct acoustic properties, acoustic measurements are performed using a scanning acoustic macroscope. Mechanical measurements are also performed to test the elasticity and density properties. TMMs with the correct properties are subsequently put through a series of moulding procedures to produce the anthropomorphic phantom.

  12. Existing Evidence on Ultrasound-Guided Injections in Sports Medicine.

    Science.gov (United States)

    Daniels, Eldra W; Cole, David; Jacobs, Bret; Phillips, Shawn F

    2018-02-01

    Office-based ultrasonography has become increasingly available in many settings, and its use to guide joint and soft tissue injections has increased. Numerous studies have been conducted to evaluate the use of ultrasound-guided injections over traditional landmark-guided injections, with a rapid growth in the literature over the past few years. A comprehensive review of the literature was conducted to demonstrate increased accuracy of ultrasound-guided injections regardless of anatomic location. In the upper extremity, ultrasound-guided injections have been shown to provide superior benefit to landmark-guided injections at the glenohumeral joint, the subacromial space, the biceps tendon sheath, and the joints of the hand and wrist. Ultrasound-guided injections of the acromioclavicular and the elbow joints have not been shown to be more efficacious. In the lower extremity, ultrasound-guided injections at the knee, ankle, and foot have superior efficacy to landmark-guided injections. Conclusive evidence is not available regarding improved efficacy of ultrasound-guided injections of the hip, although landmark-guided injection is performed less commonly at the hip joint. Ultrasound-guided injections are overall more accurate than landmark-guided injections. While current studies indicate that ultrasound guidance improves efficacy and cost-effectiveness of many injections, these studies are limited and more research is needed.

  13. [Ultrasound-guided peripheral catheterization].

    Science.gov (United States)

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  14. MRI-guided vacuum-assisted breast biopsy: comparison with stereotactically guided and ultrasound-guided techniques

    Energy Technology Data Exchange (ETDEWEB)

    Imschweiler, Thomas; Freiwald, Bianka; Kubik-Huch, Rahel A. [Kantonspital Baden AG, Institute for Radiology, Baden (Switzerland); Haueisen, Harald [Kantonspital Aarau AG, Institute for Radiology, Aarau (Switzerland); Kampmann, Gert [Clinica Sant' Anna, Lugano, Sorengo (Switzerland); Rageth, Luzi [Adjumed Services AG, Zurich (Switzerland); Seifert, Burkhardt [Institute for Social and Preventive Medicine, University of Zurich, Division of Biostatistics, Zuerich (Switzerland); Rageth, Christoph [Breast Centre, Zurich (Switzerland)

    2014-01-15

    To analyse the development of MRI-guided vacuum-assisted biopsy (VAB) in Switzerland and to compare the procedure with stereotactically guided and ultrasound-guided VAB. We performed a retrospective analysis of VABs between 2009 and 2011. A total of 9,113 VABs were performed. Of these, 557 were MRI guided. MRI-guided VAB showed the highest growth rate (97 %) of all three procedures. The technical success rates for MRI-guided, stereotactically guided and ultrasound-guided VAB were 98.4 % (548/557), 99.1 % (5,904/5,960) and 99.6 % (2,585/2,596), respectively. There were no significant differences (P = 0.12) between the MRI-guided and the stereotactically guided procedures. The technical success rate for ultrasound-guided VAB was significantly higher than that for MRI-guided VAB (P < 0.001). There were no complications using MRI-guided VAB requiring open surgery. The malignancy diagnosis rate for MRI-guided VAB was similar to that for stereotactically guided VAB (P = 0.35). MRI-guided VAB is a safe and accurate procedure that provides insight into clinical breast findings. (orig.)

  15. Investigation of vessel visibility of iterative reconstruction method in coronary computed tomography angiography using simulated vessel phantom

    International Nuclear Information System (INIS)

    Inoue, Takeshi; Uto, Fumiaki; Ichikawa, Katsuhiro; Hara, Takanori; Urikura, Atsushi; Hoshino, Takashi; Miura, Youhei; Terakawa, Syouichi

    2012-01-01

    Iterative reconstruction methods can reduce the noise of computed tomography (CT) images, which are expected to contribute to the reduction of patient dose CT examinations. The purpose of this study was to investigate impact of an iterative reconstruction method (iDose 4 , Philips Healthcare) on vessel visibility in coronary CT angiography (CTA) by using phantom studies. A simulated phantom was scanned by a CT system (iCT, Philips Healthcare), and the axial images were reconstructed by filtered back projection (FBP) and given a level of 1 to 7 (L1-L7) of the iterative reconstruction (IR). The vessel visibility was evaluated by a quantitative analysis using profiles across a 1.5-mm diameter simulated vessel as well as visual evaluation for multi planar reformation (MPR) images and volume rendering (VR) images in terms of the normalized-rank method with analysis of variance. The peak CT value of the profiles decreased with IR level and full width at half maximum of the profile also decreased with the IR level. For normalized-rank method, there was no statistical difference between FBP and L1 (20% dose reduction) for both MPR and VR images. The IR levels higher than L1 sacrificed the spatial resolution for the 1.5-mm simulated vessel, and their visual vessel visibilities were significantly inferior to that of the FBP. (author)

  16. Comparison of Ultrasound Attenuation and Backscatter Estimates in Layered Tissue-Mimicking Phantoms among Three Clinical Scanners

    Science.gov (United States)

    Nam, Kibo; Rosado-Mendez, Ivan M.; Wirtzfeld, Lauren A.; Ghoshal, Goutam; Pawlicki, Alexander D.; Madsen, Ernest L.; Lavarello, Roberto J.; Oelze, Michael L.; Zagzebski, James A.; O’Brien, William D.; Hall, Timothy J.

    2013-01-01

    Backscatter and attenuation coefficient estimates are needed in many quantitative ultrasound strategies. In clinical applications, these parameters may not be easily obtained because of variations in scattering by tissues overlying a region of interest (ROI). The goal of this study is to assess the accuracy of backscatter and attenuation estimates for regions distal to nonuniform layers of tissue-mimicking materials. In addition, this work compares results of these estimates for “layered” phantoms scanned using different clinical ultrasound machines. Two tissue-mimicking phantoms were constructed, each exhibiting depth-dependent variations in attenuation or backscatter. The phantoms were scanned with three ultrasound imaging systems, acquiring radio frequency echo data for offline analysis. The attenuation coefficient and the backscatter coefficient (BSC) for sections of the phantoms were estimated using the reference phantom method. Properties of each layer were also measured with laboratory techniques on test samples manufactured during the construction of the phantom. Estimates of the attenuation coefficient versus frequency slope, α0, using backscatter data from the different systems agreed to within 0.24 dB/cm-MHz. Bias in the α0 estimates varied with the location of the ROI. BSC estimates for phantom sections whose locations ranged from 0 to 7 cm from the transducer agreed among the different systems and with theoretical predictions, with a mean bias error of 1.01 dB over the used bandwidths. This study demonstrates that attenuation and BSCs can be accurately estimated in layered inhomogeneous media using pulse-echo data from clinical imaging systems. PMID:23160474

  17. A novel graphical user interface for ultrasound-guided shoulder arthroscopic surgery

    Science.gov (United States)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Pichora, D.; Abolmaesumi, P.

    2007-03-01

    This paper presents a novel graphical user interface developed for a navigation system for ultrasound-guided computer-assisted shoulder arthroscopic surgery. The envisioned purpose of the interface is to assist the surgeon in determining the position and orientation of the arthroscopic camera and other surgical tools within the anatomy of the patient. The user interface features real time position tracking of the arthroscopic instruments with an optical tracking system, and visualization of their graphical representations relative to a three-dimensional shoulder surface model of the patient, created from computed tomography images. In addition, the developed graphical interface facilitates fast and user-friendly intra-operative calibration of the arthroscope and the arthroscopic burr, capture and segmentation of ultrasound images, and intra-operative registration. A pilot study simulating the computer-aided shoulder arthroscopic procedure on a shoulder phantom demonstrated the speed, efficiency and ease-of-use of the system.

  18. Models to teach lung sonopathology and ultrasound-guided thoracentesis

    Directory of Open Access Journals (Sweden)

    Jacek A. Wojtczak

    2014-12-01

    Full Text Available Lung sonography allows rapid diagnosis of lung emergencies such as pulmonary edema, hemothorax or pneumothorax. The ability to timely diagnose an intraoperative pneumothorax is an important skill for the anesthesiologist. However, lung ultrasound exams require an interpretation of not only real images but also complex acoustic artifacts such as A-lines and B-lines. Therefore, appropriate training to gain proficiency is important. Simulated environment using ultrasound phantom models allows controlled, supervised learning. We have developed hybrid models that combine dry or wet polyurethane foams, porcine rib cages and human hand simulating a rib cage. These models simulate fairly accurately pulmonary sonopathology and allow supervised teaching of lung sonography with the immediate feedback. In-vitro models can also facilitate learning of procedural skills, improving transducer and needle positioning and movement, rapid recognition of thoracic anatomy and hand – eye coordination skills. We described a new model to teach an ultrasound guided thoracentesis. This model consists of the experimenter’s hand placed on top of the water-filled container with a wet foam. Metacarpal bones of the human hand simulate a rib cage and a wet foam simulates a diseased lung immersed in the pleural fluid. Positive fluid flow offers users feedback when a simulated pleural effusion is accurately assessed.

  19. Dynamics of micro-bubble sonication inside a phantom vessel

    KAUST Repository

    Qamar, Adnan; Samtaney, Ravi; Bull, Joseph L.

    2013-01-01

    A model for sonicated micro-bubble oscillations inside a phantom vessel is proposed. The model is not a variant of conventional Rayleigh-Plesset equation and is obtained from reduced Navier-Stokes equations. The model relates the micro-bubble oscillation dynamics with geometric and acoustic parameters in a consistent manner. It predicts micro-bubble oscillation dynamics as well as micro-bubble fragmentation when compared to the experimental data. For large micro-bubble radius to vessel diameter ratios, predictions are damped, suggesting breakdown of inherent modeling assumptions for these cases. Micro-bubble response with acoustic parameters is consistent with experiments and provides physical insight to the micro-bubble oscillation dynamics.

  20. Dynamics of micro-bubble sonication inside a phantom vessel

    KAUST Repository

    Qamar, Adnan

    2013-01-10

    A model for sonicated micro-bubble oscillations inside a phantom vessel is proposed. The model is not a variant of conventional Rayleigh-Plesset equation and is obtained from reduced Navier-Stokes equations. The model relates the micro-bubble oscillation dynamics with geometric and acoustic parameters in a consistent manner. It predicts micro-bubble oscillation dynamics as well as micro-bubble fragmentation when compared to the experimental data. For large micro-bubble radius to vessel diameter ratios, predictions are damped, suggesting breakdown of inherent modeling assumptions for these cases. Micro-bubble response with acoustic parameters is consistent with experiments and provides physical insight to the micro-bubble oscillation dynamics.

  1. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.

    Science.gov (United States)

    Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R

    2017-07-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  2. Yield and Safety Profile of Ultrasound Guided Fine Needle Aspiration Cytology (FNAC) of Lymph Nodes

    International Nuclear Information System (INIS)

    Sattar, A.; Wahab, S.; Javed, A.; Shamim, S. H.

    2016-01-01

    Objective: To determine the re-biopsy rate, positive yield and safety profile of ultrasound guided fine needle aspiration cytology (FNAC) in cervical lymph nodes in terms of its complications and repeat procedures. Study Design: An analytical study. Place and Duration of Study: Department of Vascular and Interventional Radiology, Dow University Hospital, Dow University of Health Sciences, Karachi, from June to December 2013. Methodology: Eighty neck swellings, which were found to be lymph nodes on ultrasound, underwent ultrasound guided FNAC, from outpatients. Lymph nodes which were included in the study were those that were not easily palpable, located near major blood vessels, where patient refused of direct palpation and wanted image guided FNAC, those directly sent by physician for image guided FNAC and where blind biopsy remained inconclusive. Patients who refused on explanation or did not give consent were excluded. Complications and repeat biopsy were noted. Result: This study consisted of 80 cases, of which 51 cases (63.75 percentage) were female and 29 cases (36.25 percentage) were male. Repeat biopsy was required in 1 case (1.6 percentage). There were no procedure-related complications. A total of 44 cases (55 percentage) revealed evidence suggesting or confirming the existence of tuberculosis. Rest of the others showed other benign lesions, reactive lymphadenopathy and malignancy. Conclusion: Ultrasound guided FNAC is a safe procedure with low re-biopsy rate that aids diagnosis. The predominant cause of cervical lymphadenopathy in this study was tuberculous lymphadenitis. (author)

  3. Ultrasound-controlled neuronavigator-guided brain surgery.

    Science.gov (United States)

    Koivukangas, J; Louhisalmi, Y; Alakuijala, J; Oikarinen, J

    1993-07-01

    The development of a unique neurosurgical navigator is described and a preliminary series of seven cases of intracerebral lesions approached with the assistance of this neuronavigation system under ultrasound control is presented. The clinical series included five low-grade astrocytomas, one chronic intracerebral hematoma, and one porencephalic cyst. Management procedures included biopsy in all cases, drainage of the hematoma, and endoscopy and fenestration for the cyst. The features of the neuronavigation system are interactive reconstructions of preoperative computerized tomography and magnetic resonance imaging data, corresponding intraoperative ultrasound images, versatility of the interchangeable end-effector instruments, graphic presentation of instruments on the reconstructed images, and voice control of the system. The principle of a common axis in the reconstructed images served to align the navigational pointer, biopsy guide, endoscope guide, ultrasound transducer, and surgical microscope to the brain anatomy. Intraoperative ultrasound imaging helped to verify the accuracy of the neuronavigator and check the results of the procedures. The arm of the neuronavigation system served as a holder for instruments, such as the biopsy guide, endoscope guide, and ultrasound transducer, in addition to functioning as a navigational pointer. Also, the surgical microscope was aligned with the neuronavigator for inspection and biopsy of the hematoma capsule to rule out tumor etiology. Voice control freed the neurosurgeon from manual exercises during start-up and calibration of the system.

  4. An experimental system for the study of ultrasound exposure of isolated blood vessels

    International Nuclear Information System (INIS)

    Tokarczyk, Anna; Rivens, Ian; Symonds-Tayler, Richard; Ter Haar, Gail; Van Bavel, E

    2013-01-01

    An experimental system designed for the study of the effects of diagnostic or therapeutic ultrasound exposure on isolated blood vessels in the presence or absence of intraluminal contrast agent is described. The system comprised several components. A microscope was used to monitor vessel size (and thus vessel functionality), and potential leakage of intraluminal 70 kDa FITC-dextran fluorescence marker. A vessel chamber allowed the mounting of an isolated vessel whilst maintaining its viability, with pressure regulation for the control of intraluminal pressure and induction of flow for the infusion of contrast microbubbles. A fibre-optic hydrophone sensor mounted on the vessel chamber using a micromanipulator allowed pre-exposure targeting of the vessel to within 150 µm, and monitoring of acoustic cavitation emissions during exposures. Acoustic cavitation was also detected using changes in the ultrasound drive voltage and by detection of audible emissions using a submerged microphone. The suitability of this system for studying effects in the isolated vessel model has been demonstrated using a pilot study of 6 sham exposed and 18 high intensity focused ultrasound exposed vessels, with or without intraluminal contrast agent (SonoVue) within the vessels. (paper)

  5. Non-invasive ultrasound-based temperature imaging for monitoring radiofrequency heating-phantom results

    International Nuclear Information System (INIS)

    Daniels, M J; Varghese, T; Madsen, E L; Zagzebski, J A

    2007-01-01

    Minimally invasive therapies (such as radiofrequency ablation) are becoming more commonly used in the United States for the treatment of hepatocellular carcinomas and liver metastases. Unfortunately, these procedures suffer from high recurrence rates of hepatocellular carcinoma (∼34-55%) or metastases following ablation therapy. The ability to perform real-time temperature imaging while a patient is undergoing radiofrequency ablation could provide a significant reduction in these recurrence rates. In this paper, we demonstrate the feasibility of ultrasound-based temperature imaging on a tissue-mimicking phantom undergoing radiofrequency heating. Ultrasound echo signals undergo time shifts with increasing temperature, which are tracked using 2D correlation-based speckle tracking methods. Time shifts or displacements in the echo signal are accumulated, and the gradient of these time shifts are related to changes in the temperature of the tissue-mimicking phantom material using a calibration curve generated from experimental data. A tissue-mimicking phantom was developed that can undergo repeated radiofrequency heating procedures. Both sound speed and thermal expansion changes of the tissue-mimicking material were measured experimentally and utilized to generate the calibration curve relating temperature to the displacement gradient. Temperature maps were obtained, and specific regions-of-interest on the temperature maps were compared to invasive temperatures obtained using fiber-optic temperature probes at the same location. Temperature elevation during a radiofrequency ablation procedure on the phantom was successfully tracked to within ±0.5 0 C

  6. Inexpensive homemade models for ultrasound-guided vein cannulation training.

    Science.gov (United States)

    Di Domenico, Stefano; Santori, Gregorio; Porcile, Elisa; Licausi, Martina; Centanaro, Monica; Valente, Umberto

    2007-11-01

    To test the hypothesis that low-cost homemade models may be used to acquire the basic skills for ultrasound-guided central vein puncture. Training study. University transplantation department. Training was performed using three different homemade models (A, B, and C). Segments of a common rubber tourniquet (V1) and Silastic tube (V2) were used to simulate vessels within agar-based models. Overall cost for each model was less than 5 euro (US$7). For each test (test I, A-V1; II, A-V2; III, B-V1; IV, C-V2), the number of punctures and attempts needed to locate the needle inside the lumen were recorded. Each test was considered completed when participants punctured the vessels at the first attempt for three consecutive times. In test I, the mean number of punctures and attempts were 3.85 +/- 1.26 and 4.95 +/- 3.05; in test II, 4.60 +/- 1.14 and 6.30 +/- 2.51; in test III, 4.80 +/- 1.06 and 4.65 +/- 2.21; and in test IV, 4.45 +/- 1.23 and 6.05 +/- 2.92, respectively. For each test, no statistical difference was found by comparison of number of punctures and attempts for anesthesiologists versus nonanesthesiologists, men versus women, or previous experience versus no experience with central vein cannulation (CVC). Video game users obtained better results than did nonusers in test I (punctures, P = 0.033; attempts, P = 0.038), test II (punctures, P = 0.052; attempts, P = 0.011), and test IV (punctures, P = 0.001; attempts, P = 0.003). A posttraining questionnaire showed favorable opinions about the clarity of the instructions, aptness of the models, and adequacy of the training. In our operative unit, the use of ultrasound guidance for CVC increased from 2% to 23% in the first month after training. Low-cost homemade models are useful in acquiring basic coordination skills for ultrasound-guided CVC.

  7. Palpation- and ultrasound-guided brachial plexus blockade in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    da Cunha, Anderson F; Strain, George M; Rademacher, Nathalie; Schnellbacher, Rodney; Tully, Thomas N

    2013-01-01

    To compare palpation-guided with ultrasound-guided brachial plexus blockade in Hispaniolan Amazon parrots. Prospective randomized experimental trial. Eighteen adult Hispaniolan Amazon parrots (Amazona ventralis) weighing 252-295 g. After induction of anesthesia with isoflurane, parrots received an injection of lidocaine (2 mg kg(-1)) in a total volume of 0.3 mL at the axillary region. The birds were randomly assigned to equal groups using either palpation or ultrasound as a guide for the brachial plexus block. Nerve evoked muscle potentials (NEMP) were used to monitor effectiveness of brachial plexus block. The palpation-guided group received the local anesthetic at the space between the pectoral muscle, triceps, and supracoracoideus aticimus muscle, at the insertion of the tendons of the caudal coracobrachial muscle, and the caudal scapulohumeral muscle. For the ultrasound-guided group, the brachial plexus and the adjacent vessels were located with B-mode ultrasonography using a 7-15 MHz linear probe. After location, an 8-5 MHz convex transducer was used to guide injections. General anesthesia was discontinued 20 minutes after lidocaine injection and the birds recovered in a padded cage. Both techniques decreased the amplitude of NEMP. Statistically significant differences in NEMP amplitudes, were observed within the ultrasound-guided group at 5, 10, 15, and 20 minutes after injection and within the palpation-guided group at 10, 15, and 20 minutes after injection. There was no statistically significant difference between the two groups. No effect on motor function, muscle relaxation or wing droop was observed after brachial plexus block. The onset of the brachial plexus block tended to be faster when ultrasonography was used. Brachial plexus injection can be performed in Hispaniolan Amazon parrots and nerve evoked muscle potentials were useful to monitor the effects on nerve conduction in this avian species. Neither technique produced an effective block at the

  8. Hydrogel based tissue mimicking phantom for in-vitro ultrasound contrast agents studies.

    Science.gov (United States)

    Demitri, Christian; Sannino, Alessandro; Conversano, Francesco; Casciaro, Sergio; Distante, Alessandro; Maffezzoli, Alfonso

    2008-11-01

    Ultrasound medical imaging (UMI) is the most widely used image analysis technique, and often requires advanced in-vitro set up to perform morphological and functional investigations. These studies are based on contrast properties both related to tissue structure and injectable contrast agents (CA). In this work, we present a three-dimensional structure composed of two different hydrogels reassembly the microvascular network of a human tissue. This phantom was particularly suitable for the echocontrastographic measurements in human microvascular system. This phantom has been characterized to present the acoustic properties of an animal liver, that is, acoustic impedance (Z) and attenuation coefficient (AC), in UMI signal analysis in particular; the two different hydrogels have been selected to simulate the target organ and the acoustic properties of the vascular system. The two hydrogels were prepared starting from cellulose derivatives to simulating the target organ parenchyma and using a PEG-diacrylate to reproduce the vascular system. Moreover, harmonic analysis was performed on the hydrogel mimicking the liver parenchyma hydrogel to evaluate the ultrasound (US) distortion during echographic measurement. The phantom was employed in the characterization of an experimental US CA. Perfect agreement was found when comparing the hydrogel acoustical properties materials with the corresponding living reference tissues (i.e., vascular and parenchimal tissue).

  9. Superficial Ultrasound Shear Wave Speed Measurements in Soft and Hard Elasticity Phantoms: Repeatability and Reproducibility Using Two Different Ultrasound Systems

    Science.gov (United States)

    Dillman, Jonathan R.; Chen, Shigao; Davenport, Matthew S.; Zhao, Heng; Urban, Matthew W.; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L.

    2014-01-01

    Background There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. Purpose To assess the repeatability and reproducibility of superficial shear wave speed (SWS) measurements acquired from elasticity phantoms at varying imaging depths using three different imaging methods, two different ultrasound systems, and multiple operators. Methods and Materials Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems, Inc. (Norfolk, VA) were utilized for our investigation. Institution #1 used an Acuson S3000 ultrasound system (Siemens Medical Solutions USA, Inc.) and three different shear wave imaging method/transducer combinations, while institution #2 used an Aixplorer ultrasound system (Supersonic Imagine) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0, 2.5, and 4.0 cm) by four operators at each institution. Student’s t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single measure intra-class correlation coefficients and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. Results For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (p=0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (p>0.05). The coefficients of variation were low (0.5–6.8%), and inter-operator agreement was near-perfect (ICCs ≥0.99). Shear wave imaging method and imaging depth

  10. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Me [Dankook University Hospital, Seoul (Korea, Republic of); Park, Hee Boong [Park Breast Clinic, Seoul (Korea, Republic of); Ryu, Jin Woo [Cheonan Choongmu Hospital, Cheonan (Korea, Republic of)

    2005-08-15

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images.

  11. Usefulness of ultrasound-guided mammotome biopsy for microcalcification

    International Nuclear Information System (INIS)

    Kim, You Me; Park, Hee Boong; Ryu, Jin Woo

    2005-01-01

    To evaluate the usefulness of ultrasound-guided mammotome biopsy for microcalcification and to suggest a new approach for the localization of microcalcifications which are not detected on ultrasound. Twenty-one calcific lesions in 21 women (aged 33-56 years) underwent ultrasound-guided, vacuum-assisted, mammotome biopsy and a mean of 14 specimens per lesion were obtained. Calcification retrieval was defined as identification of calcifications on specimen radiographs. In the 13 cases of calcifications which were not detected on ultrasound imaging, mammotome biopsy was performed after localization of one or two needles at the microcalcifications under mammography-guidance. Radiographs of the specimens and histologic findings were reviewed and scheduled follow-up imaging was performed for evaluation of the complications of biopsy. Ultrasound-guided, vacuum-assisted, mammotome biopsy removed all calcifications in 21 lesions. Eight (38%) lesions showed visible calcification on the ultrasound while 13 (62%) lesions were invisible, which underwent mammotome biopsy after needle localization under mammography-guidance. Surgery revealed DCIS in 1 (4.8%) of 21 lesions, infiltrating ductal carcinoma in two (9.5%), fibroadenomas with calcifications in 6 (28.6%), fibroadenmas with adenosis in 2(9.5%), and fibrocystic change with calcifications in 10 (47.6%). Clinical significant complications did not occur on follow-up examination in any of the cases. Ultrasound-guided, vacuum-assisted, mammotome biopsy was an effective method for microcalcifications on mammogram. The results suggested that mammotome biopsy after mammogram-guided, needle localization is a good alternative method for the diagnosis of microcalcifications which are undetectable in the ultrasound images

  12. Endoscopic ultrasound-guided biliary drainage using a newly designed metal stent with a thin delivery system: a preclinical study in phantom and porcine models.

    Science.gov (United States)

    Minaga, Kosuke; Kitano, Masayuki; Itonaga, Masahiro; Imai, Hajime; Miyata, Takeshi; Yamao, Kentaro; Tamura, Takashi; Nuta, Junya; Warigaya, Kenji; Kudo, Masatoshi

    2017-12-08

    This study was designed to evaluate the feasibility and safety of a newly designed self-expandable metal stent for endoscopic ultrasound-guided biliary drainage (EUS-BD) when it was delivered via three different stent delivery systems: a 7.5Fr delivery catheter with a bullet-shaped tip (7.5Fr-bullet), a 7Fr catheter with a bullet-shaped tip (7Fr-bullet), or a 7Fr catheter with a tee-shaped tip (7Fr-tee). This experimental study utilized a porcine model of biliary dilatation involving ten pigs. In the animal study, technical feasibility and clinical outcomes of the stent when placed with each of the delivery systems were examined. In addition, a phantom model was used to measure the resistance of these delivery systems to advancement. Phantom experiments showed that, compared with 7Fr-bullet, 7Fr-tee had less resistance force to the advancement of the stent delivery system. EUS-BD was technically successful in all ten pigs. Fistulous tract dilation was necessary in 100% (2/2), 75% (3/4), and 0% (0/4) of the pigs that underwent EUS-BD using 7.5Fr-bullet, 7Fr-bullet, and 7Fr-tee, respectively. There were no procedure-related complications. Our newly designed metal stent may be feasible and safe for EUS-BD, particularly when delivered by 7Fr-tee, because it eliminates the need for fistulous tract dilation.

  13. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  14. Tracked "Pick-Up" Ultrasound for Robot-Assisted Minimally Invasive Surgery.

    Science.gov (United States)

    Schneider, Caitlin; Nguan, Christopher; Rohling, Robert; Salcudean, Septimiu

    2016-02-01

    We present a novel "pick-up" ultrasound transducer for intraabdominal robot-assisted minimally invasive surgery. Such a "pick-up" ultrasound transducer is inserted through an abdominal incision at the beginning of the procedure and remains in the abdominal cavity throughout, eliminating the need for a dedicated port or a patient bedside surgical assistant. The transducer has a handle that can be grasped in a repeatable manner using a da Vinci Prograsp tool, allowing the transducer to be accurately manipulated by the surgeon using the da Vinci Robot. This is one way to enable 3-D tracking of the transducer, and, thus, mapping of the vasculature. The 3-D vascular images can be used to register preoperative CT to intraoperative camera images. To demonstrate the feasibility of the approach, we use an ultrasound vessel phantom to register a CT surface model to extracted ultrasound vessel models. The 3-D vascular phantom images are generated by segmenting B-mode images and tracking the pick-up ultrasound transducer with the da Vinci kinematics, internal electromagnetic sensor, or visible fiducials suitable for camera tracking. Reconstruction results using da Vinci kinematics for tracking give a target registration error of 5.4 ± 1.7 mm.

  15. Outcomes of ultrasound guided renal mass biopsies.

    Science.gov (United States)

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  16. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ... Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During ...

  17. [Novel echogenic needle for ultrasound-guided peripheral nerve block "Hakko type CCR"].

    Science.gov (United States)

    Takayama, Wataru; Yasumura, Rie; Kaneko, Takehiko; Kobayashi, Yoshiro; Kamada, Takaaki; Yoshikawa, Tamotsu; Aoyama, Yasuhiko

    2009-04-01

    A novel echogenic insulated nerve block needle (CCR-needle: Echogenic Needle Type CCR; Hakko, Japan) is commercially available since 2006 in Japan. This needle has three echogenic dimples, namely corner cube reflectors (CCR) on its tip. The CCR-needle will potentially provide a significant advantage for detecting the needle tip. In this report, we firstly evaluated this new disposable echogenic needle in simulation phantom, and demonstrated improved visibility of the needle tip. Afterwards, an interscalene brachial plexus block was performed on a male patient undergoing shoulder surgery. The needle insertion procedure was the "out of plane" ultrasound-guided technique using simultaneous electrical nerve stimulation. The surgery was successfully conducted without any complications.

  18. Ultrasound-Guided Single-Injection Infraclavicular Block Versus Ultrasound-Guided Double-Injection Axillary Block: A Noninferiority Randomized Controlled Trial.

    Science.gov (United States)

    Boivin, Ariane; Nadeau, Marie-Josée; Dion, Nicolas; Lévesque, Simon; Nicole, Pierre C; Turgeon, Alexis F

    2016-01-01

    Single-injection ultrasound-guided infraclavicular block is a simple, reliable, and effective technique. A simplified double-injection ultrasound-guided axillary block technique with a high success rate recently has been described. It has the advantage of being performed in a superficial and compressible location, with a potentially improved safety profile. However, its effectiveness in comparison with single-injection infraclavicular block has not been established. We hypothesized that the double-injection ultrasound-guided axillary block would show rates of complete sensory block at 30 minutes noninferior to the single-injection ultrasound-guided infraclavicular block. After approval by our research ethics committee and written informed consent, adults undergoing distal upper arm surgery were randomized to either group I, ultrasound-guided single-injection infraclavicular block, or group A, ultrasound-guided double-injection axillary block. In group I, 30 mL of 1.5% mepivacaine was injected posterior to the axillary artery. In group A, 25 mL of 1.5% mepivacaine was injected posteromedial to the axillary artery, after which 5 mL was injected around the musculocutaneous nerve. Primary outcome was the rate of complete sensory block at 30 minutes. Secondary outcomes were the onset of sensory and motor blocks, surgical success rates, performance times, and incidence of complications. All outcomes were assessed by a blinded investigator. The noninferiority of the double-injection ultrasound-guided axillary block was considered if the limits of the 90% confidence intervals (CIs) were within a 10% margin of the rate of complete sensory block of the infraclavicular block. At 30 minutes, the rate of complete sensory block was 79% in group A (90% CI, 71%-85%) compared with 91% in group I (90% CI, 85%-95%); the upper limit of CI of group A is thus included in the established noninferiority margin of 10%. The rate of complete sensory block was lower in group A (proportion

  19. A compact mechatronic system for 3D ultrasound guided prostate interventions

    International Nuclear Information System (INIS)

    Bax, Jeffrey; Smith, David; Bartha, Laura; Montreuil, Jacques; Sherebrin, Shi; Gardi, Lori; Edirisinghe, Chandima; Fenster, Aaron

    2011-01-01

    Purpose: Ultrasound imaging has improved the treatment of prostate cancer by producing increasingly higher quality images and influencing sophisticated targeting procedures for the insertion of radioactive seeds during brachytherapy. However, it is critical that the needles be placed accurately within the prostate to deliver the therapy to the planned location and avoid complications of damaging surrounding tissues. Methods: The authors have developed a compact mechatronic system, as well as an effective method for guiding and controlling the insertion of transperineal needles into the prostate. This system has been designed to allow guidance of a needle obliquely in 3D space into the prostate, thereby reducing pubic arch interference. The choice of needle trajectory and location in the prostate can be adjusted manually or with computer control. Results: To validate the system, a series of experiments were performed on phantoms. The 3D scan of the string phantom produced minimal geometric error, which was less than 0.4 mm. Needle guidance accuracy tests in agar prostate phantoms showed that the mean error of bead placement was less then 1.6 mm along parallel needle paths that were within 1.2 mm of the intended target and 1 deg. from the preplanned trajectory. At oblique angles of up to 15 deg. relative to the probe axis, beads were placed to within 3.0 mm along a trajectory that were within 2.0 mm of the target with an angular error less than 2 deg. Conclusions: By combining 3D TRUS imaging system to a needle tracking linkage, this system should improve the physician's ability to target and accurately guide a needle to selected targets without the need for the computer to directly manipulate and insert the needle. This would be beneficial as the physician has complete control of the system and can safely maneuver the needle guide around obstacles such as previously placed needles.

  20. Methods for characterizing convective cryoprobe heat transfer in ultrasound gel phantoms.

    Science.gov (United States)

    Etheridge, Michael L; Choi, Jeunghwan; Ramadhyani, Satish; Bischof, John C

    2013-02-01

    While cryosurgery has proven capable in treating of a variety of conditions, it has met with some resistance among physicians, in part due to shortcomings in the ability to predict treatment outcomes. Here we attempt to address several key issues related to predictive modeling by demonstrating methods for accurately characterizing heat transfer from cryoprobes, report temperature dependent thermal properties for ultrasound gel (a convenient tissue phantom) down to cryogenic temperatures, and demonstrate the ability of convective exchange heat transfer boundary conditions to accurately describe freezing in the case of single and multiple interacting cryoprobe(s). Temperature dependent changes in the specific heat and thermal conductivity for ultrasound gel are reported down to -150 °C for the first time here and these data were used to accurately describe freezing in ultrasound gel in subsequent modeling. Freezing around a single and two interacting cryoprobe(s) was characterized in the ultrasound gel phantom by mapping the temperature in and around the "iceball" with carefully placed thermocouple arrays. These experimental data were fit with finite-element modeling in COMSOL Multiphysics, which was used to investigate the sensitivity and effectiveness of convective boundary conditions in describing heat transfer from the cryoprobes. Heat transfer at the probe tip was described in terms of a convective coefficient and the cryogen temperature. While model accuracy depended strongly on spatial (i.e., along the exchange surface) variation in the convective coefficient, it was much less sensitive to spatial and transient variations in the cryogen temperature parameter. The optimized fit, convective exchange conditions for the single-probe case also provided close agreement with the experimental data for the case of two interacting cryoprobes, suggesting that this basic characterization and modeling approach can be extended to accurately describe more complicated

  1. A long arm for ultrasound: a combined robotic focused ultrasound setup for magnetic resonance-guided focused ultrasound surgery.

    Science.gov (United States)

    Krafft, Axel J; Jenne, Jürgen W; Maier, Florian; Stafford, R Jason; Huber, Peter E; Semmler, Wolfhard; Bock, Michael

    2010-05-01

    Focused ultrasound surgery (FUS) is a highly precise noninvasive procedure to ablate pathogenic tissue. FUS therapy is often combined with magnetic resonance (MR) imaging as MR imaging offers excellent target identification and allows for continuous monitoring of FUS induced temperature changes. As the dimensions of the ultrasound (US) focus are typically much smaller than the targeted volume, multiple sonications and focus repositioning are interleaved to scan the focus over the target volume. Focal scanning can be achieved electronically by using phased-array US transducers or mechanically by using dedicated mechanical actuators. In this study, the authors propose and evaluate the precision of a combined robotic FUS setup to overcome some of the limitations of the existing MRgFUS systems. Such systems are typically integrated into the patient table of the MR scanner and thus only provide an application of the US wave within a limited spatial range from below the patient. The fully MR-compatible robotic assistance system InnoMotion (InnoMedic GmbH, Herxheim, Germany) was originally designed for MR-guided interventions with needles. It offers five pneumatically driven degrees of freedom and can be moved over a wide range within the bore of the magnet. In this work, the robotic system was combined with a fixed-focus US transducer (frequency: 1.7 MHz; focal length: 68 mm, and numerical aperture: 0.44) that was integrated into a dedicated, in-house developed treatment unit for FUS application. A series of MR-guided focal scanning procedures was performed in a polyacrylamide-egg white gel phantom to assess the positioning accuracy of the combined FUS setup. In animal experiments with a 3-month-old domestic pig, the system's potential and suitability for MRgFUS was tested. In phantom experiments, a total targeting precision of about 3 mm was found, which is comparable to that of the existing MRgFUS systems. Focus positioning could be performed within a few seconds

  2. PLUS: open-source toolkit for ultrasound-guided intervention systems.

    Science.gov (United States)

    Lasso, Andras; Heffter, Tamas; Rankin, Adam; Pinter, Csaba; Ungi, Tamas; Fichtinger, Gabor

    2014-10-01

    A variety of advanced image analysis methods have been under the development for ultrasound-guided interventions. Unfortunately, the transition from an image analysis algorithm to clinical feasibility trials as part of an intervention system requires integration of many components, such as imaging and tracking devices, data processing algorithms, and visualization software. The objective of our paper is to provide a freely available open-source software platform-PLUS: Public software Library for Ultrasound-to facilitate rapid prototyping of ultrasound-guided intervention systems for translational clinical research. PLUS provides a variety of methods for interventional tool pose and ultrasound image acquisition from a wide range of tracking and imaging devices, spatial and temporal calibration, volume reconstruction, simulated image generation, and recording and live streaming of the acquired data. This paper introduces PLUS, explains its functionality and architecture, and presents typical uses and performance in ultrasound-guided intervention systems. PLUS fulfills the essential requirements for the development of ultrasound-guided intervention systems and it aspires to become a widely used translational research prototyping platform. PLUS is freely available as open source software under BSD license and can be downloaded from http://www.plustoolkit.org.

  3. [Ultrasound guided percutaneous nephrolithotripsy].

    Science.gov (United States)

    Guliev, B G

    2014-01-01

    The study was aimed to the evaluation of the effectiveness and results of ultrasound guided percutaneous nephrolithotripsy (PNL) for the treatment of patients with large stones in renal pelvis. The results of PNL in 138 patients who underwent surgery for kidney stones from 2011 to 2013 were analyzed. Seventy patients (Group 1) underwent surgery with combined ultrasound and radiological guidance, and 68 patients (Group 2)--only with ultrasound guidance. The study included patients with large renal pelvic stones larger than 2.2 cm, requiring the formation of a single laparoscopic approach. Using the comparative analysis, the timing of surgery, the number of intra- and postoperative complications, blood loss and length of stay were evaluated. Percutaneous access was successfully performed in all patients. Postoperative complications (exacerbation of chronic pyelonephritis, gross hematuria) were observed in 14.3% of patients in Group 1 and in 14.7% of patients in Group 2. Bleeding requiring blood transfusion, and injuries of adjacent organs were not registered. Efficacy of PNL in the Group 1 was 95.7%; 3 (4.3%) patients required additional interventions. In Group 2, the effectiveness of PNL was 94.1%, 4 (5.9%) patients additionally underwent extracorporeal lithotripsy. There were no significant differences in the effectiveness of PNL, the volume of blood loss and duration of hospitalization. Ultrasound guided PNL can be performed in large pelvic stones and sufficient expansion of renal cavities, thus reducing radiation exposure of patients and medical staff.

  4. Ultrasound-guided sacroiliac joint injection technique.

    LENUS (Irish Health Repository)

    Harmon, Dominic

    2008-07-01

    We describe a case report and technique for using a portable ultrasound scanner and a curvilinear transducer (4-5MHz) (SonoSite Micromaxx SonoSite, Inc. 21919 30th Drive SE Bothwell W. A.) to guide sacroiliac joint (SIJ) injection. A 42-year-old male presented with chronic lower back pain centered on his left SIJ. His pain averaged 7 out of 10 (numerical rating scale). For the ultrasound-guided SIJ injection the patient was placed in the prone position. The ultrasound transducer was oriented in a transverse orientation at the level of the sacral hiatus. Here the sacral cornuae were identified. Moving the transducer laterally from here, the lateral edge of the sacrum was identified. This bony edge was followed in a cephalad direction with the transducer maintained in a transverse orientation. A second bony contour, the ileum, was identified. The cleft between both bony contours represented the sacroiliac joint. This was found at 4.5 cm depth. Real-time imaging was used to direct a 22G spinal needle into the SIJ, where solution was injected under direct vision. The patient\\'s pain intensity decreased to a 2 out of 10 (numerical rating scale). Function improved and the patient was able to return to work. These improvements were maintained at 16 weeks. Ultrasound guidance does not expose patients and personnel to radiation and is readily accessible. Ultrasound-guided SIJ injections may have particular applications in the management of chronic lower back pain in certain clinical scenarios (e.g. pregnancy). Future studies to demonstrate efficacy and reproducibility are needed.

  5. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach

    Directory of Open Access Journals (Sweden)

    Feng Mao

    2017-01-01

    Full Text Available Aim. To investigate the value of contrast-enhanced ultrasound (CEUS guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6 who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US guidance group (n=75. All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3% and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm nonenhanced necrotic areas. More inner (20.0% versus 6.7% and surrounding (18.3% versus 2.7% major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%. The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%. Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  6. Contrast-Enhanced Ultrasound Guided Biopsy of Undetermined Abdominal Lesions: A Multidisciplinary Decision-Making Approach.

    Science.gov (United States)

    Mao, Feng; Dong, Yi; Ji, Zhengbiao; Cao, Jiaying; Wang, Wen-Ping

    2017-01-01

    Aim. To investigate the value of contrast-enhanced ultrasound (CEUS) guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT) decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6) who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US) guidance group ( n = 75). All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3%) and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm) nonenhanced necrotic areas. More inner (20.0% versus 6.7%) and surrounding (18.3% versus 2.7%) major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%). The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%). Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.

  7. Point-of-Care Ultrasound-Guided Percutaneous Cannulation of Extracorporeal Membrane Oxygenation: Make it Simple.

    Science.gov (United States)

    Ahn, Hong Joon; Lee, Jun Wan; Joo, Ki Hyuk; You, Yeon Ho; Ryu, Seung; Lee, Jin Woong; Kim, Seung Whan

    2017-12-30

    Cannulation of the great vessels is required for extracorporeal membrane oxygenation (ECMO). Currently, there is no guideline for optimal imaging modalities during percutaneous cannulation of ECMO. The purpose of this study was to describe percutaneous cannulation guided by point-of-care ultrasound (POCUS) for ECMO and compare it with fluoroscopy and landmark guidance. Three groups (POCUS-, fluoroscopy-, and landmark-guided) of percutaneous cannulation for ECMO were analyzed retrospectively in a tertiary academic hospital. In the POCUS-guided group, visual confirmation of guidewire and cannula by ultrasound in both the access and return cannula were essential for successful cannulation. Fluoroscopy- and landmark-guided groups were cannulated with the conventional technique. A total of 128 patients were treated by ECMO during the study period, of which 94 (73.4%) cases were venoarterial ECMO. This included 56 cases of extracorporeal cardiopulmonary resuscitation. Also, there were 30 (23.4%) cases of venovenous ECMO and 4 (3.1%) cases of venoarteriovenous ECMO. A total of 71 (55.5%) patients were cannulated under POCUS guidance, and 43 (33.6%) patients were cannulated under fluoroscopy guidance and 14 (10.9%) patients were cannulated by landmark guidance. No surgical cut downs were required. Misplacement of cannula occurred in 3 (2.3%) cases. All three occurred in the landmark-guided group. POCUS-guided cannulation is comparable to fluoroscopy-guided cannulation in terms of avoiding cannula misplacement. In our experience, POCUS-guided cannulation is a useful strategy over fluoroscopy- and landmark-guided cannulation during peripheral ECMO. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Ultrasound guided electrochemotherapy for the treatment of a clear ...

    African Journals Online (AJOL)

    Ultrasound guided biopsy yielded a diagnosis of clear cell thymoma upon histopathology. After complete staging procedures, the owner elected to treat the cat with electrochemotherapy (ECT) using systemic bleomycin. Two sessions of ultrasound guided ECT were performed at two week intervals with trains of biphasic ...

  9. Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting.

    Science.gov (United States)

    Kim, Chunwoo; Chang, Doyoung; Petrisor, Doru; Chirikjian, Gregory; Han, Misop; Stoianovici, Dan

    2013-06-01

    Image-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device. We report a calibration method for 2-D ultrasound probes using robotic manipulation and a planar calibration rig. Moreover, a needle guide that is attached to the probe is also calibrated for ultrasound-guided needle targeting. The method is applied to a transrectal ultrasound (TRUS) probe for robot-assisted prostate biopsy. Validation experiments include TRUS-guided needle targeting accuracy tests. This paper outlines the entire process from the calibration to image-guided targeting. Freehand TRUS-guided prostate biopsy is the primary method of diagnosing prostate cancer, with over 1.2 million procedures performed annually in the U.S. alone. However, freehand biopsy is a highly challenging procedure with subjective quality control. As such, biopsy devices are emerging to assist the physician. Here, we present a method that uses robotic TRUS manipulation. A 2-D TRUS probe is supported by a 4-degree-of-freedom robot. The robot performs ultrasound scanning, enabling 3-D reconstructions. Based on the images, the robot orients a needle guide on target for biopsy. The biopsy is acquired manually through the guide. In vitro tests showed that the 3-D images were geometrically accurate, and an image-based needle targeting accuracy was 1.55 mm. These validate the probe calibration presented and the overall robotic system for needle targeting. Targeting accuracy is sufficient for targeting small, clinically significant prostatic cancer lesions, but actual in vivo targeting will include additional error components that will have to be determined.

  10. Comparison of longitudinal excursion of a nerve-phantom model using quantitative ultrasound imaging and motion analysis system methods: A convergent validity study.

    Science.gov (United States)

    Paquette, Philippe; El Khamlichi, Youssef; Lamontagne, Martin; Higgins, Johanne; Gagnon, Dany H

    2017-08-01

    Quantitative ultrasound imaging is gaining popularity in research and clinical settings to measure the neuromechanical properties of the peripheral nerves such as their capability to glide in response to body segment movement. Increasing evidence suggests that impaired median nerve longitudinal excursion is associated with carpal tunnel syndrome. To date, psychometric properties of longitudinal nerve excursion measurements using quantitative ultrasound imaging have not been extensively investigated. This study investigates the convergent validity of the longitudinal nerve excursion by comparing measures obtained using quantitative ultrasound imaging with those determined with a motion analysis system. A 38-cm long rigid nerve-phantom model was used to assess the longitudinal excursion in a laboratory environment. The nerve-phantom model, immersed in a 20-cm deep container filled with a gelatin-based solution, was moved 20 times using a linear forward and backward motion. Three light-emitting diodes were used to record nerve-phantom excursion with a motion analysis system, while a 5-cm linear transducer allowed simultaneous recording via ultrasound imaging. Both measurement techniques yielded excellent association ( r  = 0.99) and agreement (mean absolute difference between methods = 0.85 mm; mean relative difference between methods = 7.48 %). Small discrepancies were largely found when larger excursions (i.e. > 10 mm) were performed, revealing slight underestimation of the excursion by the ultrasound imaging analysis software. Quantitative ultrasound imaging is an accurate method to assess the longitudinal excursion of an in vitro nerve-phantom model and appears relevant for future research protocols investigating the neuromechanical properties of the peripheral nerves.

  11. The comparative study of CT guided and ultrasound guided percutaneous ethanol injection in the treatment of intra-abdominal cyst

    International Nuclear Information System (INIS)

    Li Heping; Yang Jianyong; Chen Wei; Zhuang Wenquan; Huang Yulian; Chen Jianye

    2005-01-01

    Objective: An comparative study of the interventional approach of CT guided and ultiasound guided percutaneous ethanol injection(PEI) in the treatment of intra-abdominal cyst. Methods: CT guided PEI was performed in the treatment of intra-abdominal cyst in 38 patients while ultrasound guided PEI was performed in 45 cases. Results: The puncture procedure of CT guided PEI was totally performed 83 times in treating 56 intra-abdominal cysts in 38 patients and CT guided PEI was unsuccessful in 6 patients. The puncture procedure of ultrasound guided PEI were performed 87 times in treating 71 intra-abdominal cysts in 55 patients and ultrasound guided PEI only failed only in 1 patient. Conclusion: Ultrasound guided PEI is superior to CT guided PEI in the treatment of intra-abdominal cyst. (authors)

  12. Ultrasound guided synovial biopsy of the wrist

    NARCIS (Netherlands)

    van Vugt, R. M.; van Dalen, A.; Bijlsma, J. W.

    1997-01-01

    Seven patients (4 female and 3 male, mean age 46) with arthritis of the wrist (n = 7) without known etiology were evaluated. High-definition ultrasound equipment was used for localization of synovial hypertrophy, suitable for ultrasound guided biopsy without risk. A 18-gauge diameter Tru-cut biopsy

  13. The future perspectives in transrectal prostate ultrasound guided biopsy

    Directory of Open Access Journals (Sweden)

    Sung Il Hwang

    2014-12-01

    Full Text Available Prostate cancer is one of the most common neoplasms in men. Transrectal ultrasound (TRUS-guided systematic biopsy has a crucial role in the diagnosis of prostate cancer. However, it shows limited value with gray-scale ultrasound alone because only a small number of malignancies are visible on TRUS. Recently, new emerging technologies in TRUS-guided prostate biopsy were introduced and showed high potential in the diagnosis of prostate cancer. High echogenicity of ultrasound contrast agent reflect the increased status of angiogenesis in tumor. Molecular imaging for targeting specific biomarker can be also used using ultrasound contrast agent for detecting angiogenesis or surface biomarker of prostate cancer. The combination of TRUS-guided prostate biopsy and ultrasound contrast agents can increase the accuracy of prostate cancer diagnosis. Elastography is an emerging ultrasound technique that can provide the information regarding tissue elasticity and stiffness. Tumors are usually stiffer than the surrounding soft tissue. In two types of elastography techniques, shearwave elastography has many potential in that it can provide quantitative information on tissue elasticity. Multiparametric magnetic resonance imaging (MRI from high resolution morphologic and functional magnetic resonance (MR technique enables to detect more prostate cancers. The combination of functional techniques including apparent diffusion coefficient map from diffusion weighted imaging, dynamic contrast enhanced MR and MR spectroscopy are helpful in the localization of the prostate cancer. MR-ultrasound (US fusion image can enhance the advantages of both two modalities. With MR-US fusion image, targeted biopsy of suspicious areas on MRI is possible and fusion image guided biopsy can provide improved detection rate. In conclusion, with recent advances in multiparametric-MRI, and introduction of new US techniques such as contrast-enhanced US and elastography, TRUS-guided biopsy

  14. Faculty staff-guided versus self-guided ultrasound training for internal medicine residents.

    Science.gov (United States)

    Alba, George A; Kelmenson, Daniel A; Noble, Vicki E; Murray, Alice F; Currier, Paul F

    2013-11-01

    Ultrasonography is of growing importance within internal medicine (IM), but the optimal method of training doctors to use it is uncertain. In this study, the authors provide the first objective comparison of two approaches to training IM residents in ultrasonography. In this randomised trial, a simulation-based ultrasound training curriculum was implemented during IM intern orientation at a tertiary care teaching hospital. All 72 incoming interns attended a lecture and were given access to online modules. Interns were then randomly assigned to a 4-hour faculty-guided (FG) or self-guided (SG) ultrasound training session in a simulation laboratory with both human and manikin models. Interns were asked to self-assess their competence in ultrasonography and underwent an objective structured clinical examination (OSCE) to assess their competence in basic and procedurally oriented ultrasound tasks. The primary outcome was the score on the OSCE. Faculty-guided training was superior to self-guided training based on the OSCE scores. Subjects in the FG training group achieved significantly higher OSCE scores on the two subsets of task completion (0.9-point difference, 95% confidence interval [CI] 0.27-1.54; p = 0.008) and ultrasound image quality (2.43-point difference, 95% CI 1.5-3.36; p training groups demonstrated an increase in self-assessed competence after their respective training sessions and there was little difference between the groups. Subjects rated the FG training group much more favourably than the SG training group. Both FG and SG ultrasound training curricula can improve the self-reported competence of IM interns in ultrasonography. However, FG training was superior to SG training in both skills acquisition and intern preference. Incorporating mandatory ultrasound training into IM residencies can address the perceived need for ultrasound training, improve confidence and procedural skills, and may enhance patient safety. However, the optimal training method

  15. Pulmonary ultrasound elastography: a feasibility study with phantoms and ex-vivo tissue

    Science.gov (United States)

    Nguyen, Man Minh; Xie, Hua; Paluch, Kamila; Stanton, Douglas; Ramachandran, Bharat

    2013-03-01

    Elastography has become widely used for minimally invasive diagnosis in many tumors as seen with breast, liver and prostate. Among different modalities, ultrasound-based elastography stands out due to its advantages including being safe, real-time, and relatively low-cost. While lung cancer is the leading cause of cancer mortality among both men and women, the use of ultrasound elastography for lung cancer diagnosis has hardly been investigated due to the limitations of ultrasound in air. In this work, we investigate the use of static-compression based endobronchial ultrasound elastography by a 3D trans-oesophageal echocardiography (TEE) transducer for lung cancer diagnosis. A water-filled balloon was designed to 1) improve the visualization of endobronchial ultrasound and 2) to induce compression via pumping motion inside the trachea and bronchiole. In a phantom study, we have successfully generated strain images indicating the stiffness difference between the gelatin background and agar inclusion. A similar strain ratio was confirmed with Philips ultrasound strain-based elastography product. For ex-vivo porcine lung study, different tissue ablation methods including chemical injection, Radio Frequency (RF) ablation, and direct heating were implemented to achieve tumor-mimicking tissue. Stiff ablated lung tissues were obtained and detected with our proposed method. These results suggest the feasibility of pulmonary elastography to differentiate stiff tumor tissue from normal tissue.

  16. Ultrasound-guided percutaneous biopsy of digestive tract lesions

    International Nuclear Information System (INIS)

    Gil, S.; Martin, I.; Ballesteros, J. M.; Gomez, C.; Marco, S. F.; Fernandez, P.

    1999-01-01

    To present our experience in ultrasound-guided percutaneous biopsy of lesions located in the digestive tract. We performed ultrasound-guided percutaneous biopsy in 14 patients (10 men and 4 women) ranging in age from 7 to 71 years (mean; 519 years). The lesions were located throughout the digestive tract, from the pyriform sinus to the sigmoid colon. The biopsy was carried out with a 5 MHz convex probe equipped with a device to direct the needle. An 18G automatic needle or a 20G Chiba needle was used to obtain specimens for histological study in every case, and additional samples were collected with a 22G needle for cytological examination in 13 of the patients. The ultrasound images corresponded to pseudokidney in 9 cases and extrinsic masses in 5. The diagnosis was obtained from the histological examination in every case (100%) and from cytology in 6 (44.4%), the latter results were less specific. The only complication corresponded to a case of bilioperitoneum. Ultrasound-guided percutaneous biopsy is a suitable technique for the histological diagnosis of those lesions of the digestive tract that are visible in ultrasound images, but that for some reason can not be examined by endoscopic biopsy. (Author) 20 refs

  17. Ultrasonographic Quantification of Fat Content in Fatty Liver Phantoms

    International Nuclear Information System (INIS)

    Kim, Il Young; Kim, Pyo Nyun; Joo, Gyung Soo; Kim, Ho Jung; Kim, Young Beom; Lee, Byoung Ho

    1995-01-01

    Assuming that the fat content of certain tissue might be quantified by measurirrg the ultrasound echo level, we analyzed the ultrasound histograms obtained from the fatty liver phantoms that contained various amount of fat. Various amount of margarine(Mazola. Cliff wood. USA) was mixed with 2% of agarin solution state to produce fatty liver phantoms that contained 5, 10, 20, 30 and 40% of fat. We obtained ultrasound histogram from each fatty liver phantom in gel state. We used 2% agar gel as a control. The ultrasound histograms from the control phantom showed gradual increase in echo level as the depth from the surface increased. The echo level from the phantom that contained 5% of fat showed gradual increase and subsequent decrease with the peak echo level at the depth of 3cm. The echo levels from the phantoms that contained more in 5% of fat gradually decreased as the depth from the surface increased; the change becoming more pronounced as the fat content of the phantom increased. The echo levels measured at the depth of 1cm were 9.3(control), 29.6(5%phantom), 3l.3 (10% phantom), 26.3 (20% phantom), l8.8 (30% phantom), and l6dB (40% phantom). Fat content of fatty phantoms can not be quantified by measuring only echo level. Simultaneous measurement of attenuation of ultrasound, which is not easy to do and not done in this study, is prerequisite to quantify fat content

  18. Temporal regularization of ultrasound-based liver motion estimation for image-guided radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    O’Shea, Tuathan P., E-mail: tuathan.oshea@icr.ac.uk; Bamber, Jeffrey C.; Harris, Emma J. [Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden NHS foundation Trust, Sutton, London SM2 5PT (United Kingdom)

    2016-01-15

    Purpose: Ultrasound-based motion estimation is an expanding subfield of image-guided radiation therapy. Although ultrasound can detect tissue motion that is a fraction of a millimeter, its accuracy is variable. For controlling linear accelerator tracking and gating, ultrasound motion estimates must remain highly accurate throughout the imaging sequence. This study presents a temporal regularization method for correlation-based template matching which aims to improve the accuracy of motion estimates. Methods: Liver ultrasound sequences (15–23 Hz imaging rate, 2.5–5.5 min length) from ten healthy volunteers under free breathing were used. Anatomical features (blood vessels) in each sequence were manually annotated for comparison with normalized cross-correlation based template matching. Five sequences from a Siemens Acuson™ scanner were used for algorithm development (training set). Results from incremental tracking (IT) were compared with a temporal regularization method, which included a highly specific similarity metric and state observer, known as the α–β filter/similarity threshold (ABST). A further five sequences from an Elekta Clarity™ system were used for validation, without alteration of the tracking algorithm (validation set). Results: Overall, the ABST method produced marked improvements in vessel tracking accuracy. For the training set, the mean and 95th percentile (95%) errors (defined as the difference from manual annotations) were 1.6 and 1.4 mm, respectively (compared to 6.2 and 9.1 mm, respectively, for IT). For each sequence, the use of the state observer leads to improvement in the 95% error. For the validation set, the mean and 95% errors for the ABST method were 0.8 and 1.5 mm, respectively. Conclusions: Ultrasound-based motion estimation has potential to monitor liver translation over long time periods with high accuracy. Nonrigid motion (strain) and the quality of the ultrasound data are likely to have an impact on tracking

  19. A randomised crossover study to compare the cross-sectional and longitudinal approaches to ultrasound-guided peripheral venepuncture in a model.

    Science.gov (United States)

    Griffiths, James; Carnegie, Amadeus; Kendall, Richard; Madan, Rajeev

    2017-12-01

    Ultrasound-guided peripheral intravenous access may present an alternative to central or intraosseous access in patients with difficult peripheral veins. Using venepuncture of a phantom model as a proxy, we investigated whether novice ultrasound users should adopt a cross-sectional or longitudinal approach when learning to access peripheral veins under ultrasound guidance. This result would inform the development of a structured training method for this procedure. We conducted a randomised controlled trial of 30 medical students. Subjects received 35 min of training, then attempted to aspirate 1 ml of synthetic blood from a deep vein in a training model under ultrasound guidance. Subjects attempted both the cross-sectional and longitudinal approaches. Group 1 used cross-sectional first, followed by longitudinal. Group 2 used longitudinal first, then cross-sectional. We measured the time from first puncture of the model's skin to aspiration of fluid, and the number of attempts required. Subjects also reported difficulty ratings for each approach. Paired sample t-tests were used for statistical analysis. The mean number of attempts was 1.13 using the cross-sectional approach, compared with 1.30 using the longitudinal approach (p = 0.17). Mean time to aspiration of fluid was 45.1 s using the cross-sectional approach and 52.8 s using the longitudinal approach (p = 0.43). The mean difficulty score out of 10 was 3.97 for the cross-sectional approach and 3.93 for the longitudinal approach (p = 0.95). We found no significant difference in effectiveness between the cross-sectional and longitudinal approaches to ultrasound-guided venepuncture when performed on a model. We believe that both approaches should be included when teaching ultrasound-guided peripheral vascular access. To confirm which approach would be best in clinical practice, we advocate future testing of both approaches on patients.

  20. Active point out-of-plane ultrasound calibration

    Science.gov (United States)

    Cheng, Alexis; Guo, Xiaoyu; Zhang, Haichong K.; Kang, Hyunjae; Etienne-Cummings, Ralph; Boctor, Emad M.

    2015-03-01

    Image-guided surgery systems are often used to provide surgeons with informational support. Due to several unique advantages such as ease of use, real-time image acquisition, and no ionizing radiation, ultrasound is a common intraoperative medical imaging modality used in image-guided surgery systems. To perform advanced forms of guidance with ultrasound, such as virtual image overlays or automated robotic actuation, an ultrasound calibration process must be performed. This process recovers the rigid body transformation between a tracked marker attached to the transducer and the ultrasound image. Point-based phantoms are considered to be accurate, but their calibration framework assumes that the point is in the image plane. In this work, we present the use of an active point phantom and a calibration framework that accounts for the elevational uncertainty of the point. Given the lateral and axial position of the point in the ultrasound image, we approximate a circle in the axial-elevational plane with a radius equal to the axial position. The standard approach transforms all of the imaged points to be a single physical point. In our approach, we minimize the distances between the circular subsets of each image, with them ideally intersecting at a single point. We simulated in noiseless and noisy cases, presenting results on out-of-plane estimation errors, calibration estimation errors, and point reconstruction precision. We also performed an experiment using a robot arm as the tracker, resulting in a point reconstruction precision of 0.64mm.

  1. Randomized trial of tourniquet vs blood pressure cuff for target vein dilation in ultrasound-guided peripheral intravenous access.

    Science.gov (United States)

    Nelson, Drew; Jeanmonod, Rebecca; Jeanmonod, Donald

    2014-07-01

    Ten percent of the time, peripheral intravenous access (PIV) is not obtained in 2 attempts in the emergency department. Typically, a tourniquet is used to dilate the target vein; but recent research showed that a blood pressure (BP) cuff improves dilation, which may translate to increased PIV success. We sought to determine if there is improved success in obtaining ultrasound-guided PIV using a BP cuff vs a tourniquet in "difficult stick" patients. This is a prospective, randomized, single-blinded trial. Adult patients requiring PIV with at least 2 prior failed attempts were enrolled. Patients were assigned to tourniquet or BP cuff for target vein dilation randomly. Nurses prepared the patient for PIV attempt by either placing a BP cuff inflated to 150 mm Hg or placing a tourniquet on the chosen extremity. The extremity was draped to blind the physician to assignment. Physicians then attempted ultrasound-guided PIV. Failures were defined as IVs requiring greater than 3 ultrasound-guided attempts or 30 minutes, or patient intolerance. If failure occurred, the physician was unblinded; and the patient could be crossed over and reattempted. Thirty-eight patients were enrolled. The success rate for the tourniquet group (n = 17) and BP cuff group (n = 21) was 82.4% and 47.6%, respectively (P = .04). There were no differences between groups for vessel depth, diameter, or procedure time. Six in the BP cuff group were crossed over and had successful PIV obtained with tourniquet. Tourniquet is superior to BP cuff for target vein dilation in ultrasound-guided PIV. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. A New Ultrasound-Guided Puncture Device with Augmented Degrees of Performance Freedom and Ability to Attach to Most Convex Probes

    International Nuclear Information System (INIS)

    Jung, Sung Il; Son, Kyu Ri; Kim, Young Jun; Jeon, Hae Jeong; Park, Sang Woo; Cho, Jeong Yeon; Kim, Seung Hyup

    2008-01-01

    To evaluate the performance of a newly-designed ultrasound (US)-guided puncture device. A newly-designed US-guided puncture device was composed of a guide segment and an attachable segment. The guide segment allowed the needle to be placed in the plane of US view with a maximal degree of freedom, and the attachable segment was designed to attach to most convex US probes. Six operators punctured 144 targets in phantoms using either the new device (n = 72) or free-hand technique (n = 72). The number of required needle passages and the necessary procedure times were compared between the two groups. The number of required needle passages and the necessary procedure time were significantly reduced in five operators when the newly-designed US-guided puncture device was used (p < 0.05). A newly-designed US-guided puncture device, which allows for a maximal degree of freedom in needle placement and can attach to most convex US probes, showed good performance in our study

  3. An experimental system for the study of ultrasound exposure of isolated blood vessels

    NARCIS (Netherlands)

    Tokarczyk, Anna; Rivens, Ian; van Bavel, E.; Symonds-Tayler, Richard; ter Haar, Gail

    2013-01-01

    An experimental system designed for the study of the effects of diagnostic or therapeutic ultrasound exposure on isolated blood vessels in the presence or absence of intraluminal contrast agent is described. The system comprised several components. A microscope was used to monitor vessel size (and

  4. Comparison of ultrasound-guided versus anatomical landmark ...

    African Journals Online (AJOL)

    Background Femoral vein cannulation may be required during major surgery in infants and children and may prove to be life saving under certain conditions. This study compared ultrasound (US)-guided cannulation of the femoral vein in infants with the traditional anatomical landmark-guided technique. Methods Eighty ...

  5. Effects of line fiducial parameters and beamforming on ultrasound calibration

    OpenAIRE

    Ameri, Golafsoun; Baxter, John S. H.; McLeod, A. Jonathan; Peters, Terry M.; Chen, Elvis C. S.

    2017-01-01

    Ultrasound (US)-guided interventions are often enhanced via integration with an augmented reality environment, a necessary component of which is US calibration. Calibration requires the segmentation of fiducials, i.e., a phantom, in US images. Fiducial localization error (FLE) can decrease US calibration accuracy, which fundamentally affects the total accuracy of the interventional guidance system. Here, we investigate the effects of US image reconstruction techniques as well as phantom mater...

  6. An experimental study on feasibility of ex-vessel cooling through the external guide vessel

    International Nuclear Information System (INIS)

    Kang, Kyoung-Ho; Kim, Jong-Hwan; Park, Rae-Jun; Kim, Sang-Baik

    2000-01-01

    This paper presents the results of a series of experiments for assessing the efficacy of ex-vessel cooling through the external guide vessel during a severe accident. Four tests were performed in the LAVA test facility at KAERI, varying the boundary conditions at the outer surface of the vessel. The first test was a dry condition test conducted without cooling the outside of the vessel. On the other hand, in the second test, the cooling of the vessel surface was produced by gravity-driven forced injection of water along the annular gap of 25 mm between the vessel and the external guide vessel. Water flow rate was about 0.85 kg/s and total mass of available water was 300 kg. For the evaluation of the water flow rate effect, the third test was performed with a pool type cooling in the annulus without any circulation of water. These two external cooling tests were performed under elevated pressure of about 1.6 MPa. Finally, the fourth test was conducted under atmospheric pressure to evaluate the effect of system pressure on boiling heat transfer characteristics. In the dry test and the pool type ex-vessel cooling test performed under atmospheric pressure, the vessel was failed by a melt penetration at about 40 degree upper position from the vessel bottom, which is coincident with the boundary of the Al 2 O 3 /Fe melt separated layers. On the other hand, in both of the ex-vessel cooling tests conducted under elevated pressure of about 1.6 MPa, the vessel didn't fail. Compared with the pool boiling test, the vessel experienced effective cooling due to the inlet flow in the forced flow test. Synthesized the results of the tests, it was shown that the heat removal with ex-vessel cooling through the guide vessel is feasible, but the additional evaluations should be performed to guarantee enough thermal margin. (author)

  7. Detecting breast microcalcifications using super-resolution and wave-equation ultrasound imaging: a numerical phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Lianjie [Los Alamos National Laboratory; Simonetti, Francesco [IMPERIAL COLLEGE LONDON; Huthwaite, Peter [IMPERIAL COLLEGE LONDON; Rosenberg, Robert [UNM; Williamson, Michael [UNM

    2010-01-01

    Ultrasound image resolution and quality need to be significantly improved for breast microcalcification detection. Super-resolution imaging with the factorization method has recently been developed as a promising tool to break through the resolution limit of conventional imaging. In addition, wave-equation reflection imaging has become an effective method to reduce image speckles by properly handling ultrasound scattering/diffraction from breast heterogeneities during image reconstruction. We explore the capabilities of a novel super-resolution ultrasound imaging method and a wave-equation reflection imaging scheme for detecting breast microcalcifications. Super-resolution imaging uses the singular value decomposition and a factorization scheme to achieve an image resolution that is not possible for conventional ultrasound imaging. Wave-equation reflection imaging employs a solution to the acoustic-wave equation in heterogeneous media to backpropagate ultrasound scattering/diffraction waves to scatters and form images of heterogeneities. We construct numerical breast phantoms using in vivo breast images, and use a finite-difference wave-equation scheme to generate ultrasound data scattered from inclusions that mimic microcalcifications. We demonstrate that microcalcifications can be detected at full spatial resolution using the super-resolution ultrasound imaging and wave-equation reflection imaging methods.

  8. Hybrid Segmentation of Vessels and Automated Flow Measures in In-Vivo Ultrasound Imaging

    DEFF Research Database (Denmark)

    Moshavegh, Ramin; Martins, Bo; Hansen, Kristoffer Lindskov

    2016-01-01

    Vector Flow Imaging (VFI) has received an increasing attention in the scientific field of ultrasound, as it enables angle independent visualization of blood flow. VFI can be used in volume flow estimation, but a vessel segmentation is needed to make it fully automatic. A novel vessel segmentation...

  9. Visibility of solid and liquid fiducial markers used for image-guided radiation therapy on optical coherence tomography: an esophageal phantom study (Conference Presentation)

    Science.gov (United States)

    Jelvehgaran, Pouya; Alderliesten, Tanja; Weda, Jelmer J. A.; de Bruin, Daniel M.; Faber, Dirk J.; Hulshof, Maarten C. C. M.; van Leeuwen, Ton G.; van Herk, Marcel B.; de Boer, Johannes F.

    2017-03-01

    Radiation therapy (RT) is used in operable and inoperable esophageal cancer patients. Endoscopic ultrasound-guided fiducial marker placement allows improved translation of the disease extent on endoscopy to computed tomography (CT) images used for RT planning and enables image-guided RT. However, microscopic tumor extent at the time of RT planning is unknown. Endoscopic optical coherence tomography (OCT) is a high-resolution (10-30µm) imaging modality with the potential for accurately determining the longitudinal disease extent. Visibility of fiducial markers on OCT is crucial for integrating OCT findings with the RT planning CT. We investigated the visibility on OCT (NinePoint Medical, Inc.) of 13 commercially available solid (Visicoil, Gold Anchor, Flexicoil, Polymark, and QLRAD) and liquid (BioXmark, Lipiodol, and Hydrogel) fiducial markers of different diameter. We designed and manufactured a set of dedicated Silicone-based esophageal phantoms to perform imaging in a controlled environment. The esophageal phantoms consist of several layers with different TiO2 concentrations to simulate the scattering properties of a typical healthy human esophagus. Markers were placed at various depths (0.5, 1.1, 2.0, and 3.0mm). OCT imaging allowed detection of all fiducial markers and phantom layers. The signal to background ratio was 6-fold higher for the solid fiducial markers than the liquid fiducial markers, yet OCT was capable of visualizing all 13 fiducial markers at all investigated depths. We conclude that RT fiducial markers can be visualized with OCT. This allows integration of OCT findings with CT for image-guided RT.

  10. Feasibility of ultrasound-guided intraarticular contrast injection for MR arthrography

    International Nuclear Information System (INIS)

    Baek, Soo Jin; Lee, Jong Min; Kang, Duck Sick

    2005-01-01

    To assess the feasibility of ultrasound-guided intraarticular contrast injection using the posterior approach for MR arthrography. Between June 2002 and October 2004, 132 patients (29 female, 103 male: mean age, 33.6 years) underwent ultrasound-guided intraarticular contrast media injection (40 ml saline + 10 ml 2% lidocaine + 0.2 ml gadopentetate dimeglumine + 0.4 ml epinephrine) for MR arthrography. The patients were classified into four groups, viz. the no leakage group, the minor leakage with successful intraarticular injection group, the major leakage with unsuccessful intraarticular injection group, and the injection failure group. The 'no leakage' and 'minor leakage' groups were considered to be technical successes, while the 'major leakage' and 'injection failure' groups were regarded as technical failures. The technical success rate of ultrasound-guided intraarticular contrast injection using the posterior approach for MR Arthrography was 99.2% (131/132 patients) and one patients 0.7% (1/132 patients) was included in the 'major leakage' group. Ultrasound-guided intraarticular contrast injection using the posterior approach for MR arthrography was feasible with a high success rate

  11. Microwave ablation of liver metastases guided by contrast-enhanced ultrasound

    DEFF Research Database (Denmark)

    Lorentzen, T; Skjoldbye, B O; Nolsoe, C P

    2011-01-01

    The aim of our study was to evaluate the efficacy of microwave (MW) ablation of liver metastases guided by B-mode ultrasound (US) and contrast-enhanced US (CEUS).......The aim of our study was to evaluate the efficacy of microwave (MW) ablation of liver metastases guided by B-mode ultrasound (US) and contrast-enhanced US (CEUS)....

  12. EFSUMB Guidelines on Interventional Ultrasound (INVUS), Part IV - EUS-guided interventions

    DEFF Research Database (Denmark)

    Jenssen, C; Hocke, M; Fusaroli, P

    2016-01-01

    The fourth part of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Guidelines on Interventional Ultrasound describes general aspects of endoscopic ultrasound-guided diagnostic and therapeutic interventions and assesses the evidence for endoscopic ultrasound-gu...

  13. Endoscopic Ultrasound-Guided Biliary Drainage

    International Nuclear Information System (INIS)

    Artifon, Everson L.A.; Ferreira, Fla'vio C.; Sakai, Paulo

    2012-01-01

    To demonstrate a comprehensive review of published articles regarding endoscopic ultrasound (EUS)-guided biliary drainage. Review of studies regarding EUS-guided biliary drainage including case reports, case series and previous reviews. EUS-guided hepaticogastrostomy, coledochoduodenostomy and choledoantrostomy are advanced biliary and pancreatic endoscopy procedures, and together make up the echo-guided biliary drainage. Hepaticogastrostomy is indicated in cases of hilar obstruction, while the procedure of choice is the coledochoduodenostomy or choledochoantrostomy in distal lesions. Both procedures must be performed only after unsuccessful ERCPs. The indication of these procedures must be made under a multidisciplinary view while sharing information with the patient or legal guardian. Hepaticogastrostomy and coledochoduodenostomy or choledochoantrostomy are feasible when performed by endoscopists with expertise in biliopancreatic endoscopy. Advanced echo-endoscopy should currently be performed under a rigorous protocol in educational institutions.

  14. Endoscopic Ultrasound-Guided Biliary Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Artifon, Everson L.A.; Ferreira, Fla& #x27; vio C.; Sakai, Paulo [University of Saeo Paulo, Saeo Paulo (Brazil)

    2012-02-15

    To demonstrate a comprehensive review of published articles regarding endoscopic ultrasound (EUS)-guided biliary drainage. Review of studies regarding EUS-guided biliary drainage including case reports, case series and previous reviews. EUS-guided hepaticogastrostomy, coledochoduodenostomy and choledoantrostomy are advanced biliary and pancreatic endoscopy procedures, and together make up the echo-guided biliary drainage. Hepaticogastrostomy is indicated in cases of hilar obstruction, while the procedure of choice is the coledochoduodenostomy or choledochoantrostomy in distal lesions. Both procedures must be performed only after unsuccessful ERCPs. The indication of these procedures must be made under a multidisciplinary view while sharing information with the patient or legal guardian. Hepaticogastrostomy and coledochoduodenostomy or choledochoantrostomy are feasible when performed by endoscopists with expertise in biliopancreatic endoscopy. Advanced echo-endoscopy should currently be performed under a rigorous protocol in educational institutions.

  15. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  16. Ultrasound-guided drainage of subcutaneous abscesses on the trunk is feasible

    DEFF Research Database (Denmark)

    Kjær, Søren; Rud, Bo; Bay-Nielsen, Morten

    2013-01-01

    Subcutaneous trunk abscesses are frequent, and current treatment options generally involve incision. By contrast, the standard care for breast abcesses is ultrasound-guided drainage. The aim of this study was to evaluate the feasibility of ultrasound-guided drainage combined with antibiotics...... in the treatment of subcutaneous abscesses on the trunk....

  17. Ultrasound-guided stellate ganglion blocks combined with pharmacological and occupational therapy in Complex Regional Pain Syndrome (CRPS): a pilot case series ad interim.

    Science.gov (United States)

    Wei, Karin; Feldmann, Robert E; Brascher, Anne-Kathrin; Benrath, Justus

    2014-12-01

    This preliminary and retrospective pilot case series examines a treatment concept consisting of ultrasound-guided stellate ganglion blocks (SGBs) combined with pharmacological and occupational therapy in patients with complex regional pain syndrome (CRPS) of the hand. Efficacy of combined treatment concepts and safety of ultrasound-guided SGB have not been sufficiently investigated yet. A total number of 156 blocks were evaluated in 16 patients with CRPS in a retrospective analysis. All patients received pharmacotherapy and a standard regimen of occupational therapy offered simultaneously to the SGBs. Changes in both spontaneous and evoked pain levels were assessed by numerical pain rating score before and after the last blockade of a series. Side effects were documented. The overall mean pain reduction was 63.2% regarding spontaneous and 45.3% regarding evoked pain. Mild complications, such as hoarseness or dysphagia, occurred in 13.5% of the blocks (21 SGBs). Serious complications, such as plexus paresis or accidental puncture of vessels or other structures, did not occur. Time between symptom onset and start of treatment did not affect the extent of pain reduction. The combination of ultrasound-guided SGB and simultaneous pharmacological and occupational therapy showed encouraging treatment results under conditions of this pilot case series. Assessment of efficacy of this combined treatment concept and safety of ultrasound-guided SGB require further prospective clinical studies with larger number of participants. Wiley Periodicals, Inc.

  18. The effect of ultrasound-guided compression immediately after transrectal ultrasound-guided prostate biopsy on postbiopsy bleeding: a randomized controlled pilot study.

    Science.gov (United States)

    Park, Bong Hee; Kim, Jung Im; Bae, Sang Rak; Lee, Yong Seok; Kang, Sung Hak; Han, Chang Hee

    2017-08-01

    To evaluate whether ultrasound-guided compression performed immediately after transrectal ultrasound (TRUS)-guided prostate biopsy decreases bleeding complications. We prospectively evaluated a total of 148 consecutive patients who underwent TRUS-guided prostate biopsy between March 2015 and July 2016. Systematic 12-core prostate biopsy was performed in all patients. Of these, 100 patients were randomly assigned to one of two groups: the compression group (n = 50) underwent TRUS-guided compression on bleeding biopsy tracts immediately after prostate biopsy, while the non-compression group (n = 50) underwent TRUS-guided prostate biopsy alone. The incidence rate and duration of hematuria, hematospermia, and rectal bleeding were compared between the two groups. The incidence rates of hematuria and hematospermia were not significantly different between the two groups (60 vs. 64%, p = 0.68; 22 vs. 30%, p = 0.362, respectively, for compression vs. non-compression group). The rectal bleeding incidence was significantly lower in the compression group as compared to the non-compression group (20 vs. 44%, p = 0.01). However, there were no significant differences in the median duration of hematuria, hematospermia, or rectal bleeding between the two groups (2, 8, and 2 days vs. 2, 10, and 1 days, p > 0.05, respectively, for compression vs. non-compression group). TRUS-guided compression [p = 0.004, odds ratio (OR) 0.25] and patient age (p = 0.013, OR 0.93) were significantly protective against the occurrence of rectal bleeding after prostate biopsy in multivariable analysis. Although it has no impact on other complications, ultrasound-guided compression on bleeding biopsy tracts performed immediately after TRUS-guided prostate biopsy is an effective and practical method to treat or decrease rectal bleeding.

  19. CT-guided procedures: evaluation of a phantom system to teach accurate needle placement

    International Nuclear Information System (INIS)

    Dimmick, S.; Jones, M.; Challen, J.; Iedema, J.; Wattuhewa, U.; Coucher, J.

    2007-01-01

    Aim: To evaluate the use of a phantom system to help teach the basic techniques of accurate CT-guided needle placement, thereby avoiding the risks associated with teaching on patients. Materials and Methods: Gelatine phantoms with five, 1.9 cm embedded spherical wooden targets were constructed. Four trainee operators performed 15 simulated biopsy procedures on the targets (series one) and repeated identical procedures 2 weeks later (series two). Statistical analysis of accuracy of needle placement and subject confidence were performed. Results: Significant sequential improvement in axial plane angular error was noted with the average error decreasing by 0.33 degrees after every five procedures performed (95% CI: -0.58 to -0.08, p = 0.01). Operator confidence indicated significant improvement both within each series and from series one to series two (95% CI: 0.08 to 1.17, p = 0.025 and 95% CI: 0.00 to 0.58, p = 0.05) respectively. However, variability in operator performance made statistically significant improvement in other variables unproven. Conclusion: Despite the study comprising a relatively small number of participants and procedures, it clearly demonstrated the effectiveness of teaching operators to perform CT-guided procedures using a phantom system. Needle placement accuracy significantly improved, with a reduction in axial angular error, and improved operator confidence without the risks associated with training on patients. Three of the operators in this study had never performed a CT-guided procedure previously, and their proficiency, after a relatively short but intense period of training, was impressive. The use of phantoms should be considered routinely for basic training of CT-guided needle placement

  20. Ultrasound- versus palpation-guided injection of corticosteroid for plantar fasciitis: a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Zonghuan Li

    Full Text Available It is controversial whether ultrasound-guided injection of corticosteroid is superior to palpation-guided injection for plantar fasciitis. This meta-analysis was performed to compare the effectiveness of ultrasound-guided and palpation-guided injection of corticosteroid for the treatment of plantar fasciitis.Databases (MEDLINE, Cochrane library and EMBASE and reference lists were searched from their establishment to August 30, 2013 for randomized controlled trials (RCTs comparing ultrasound-guided with palpation-guided injection for plantar fasciitis. The Cochrane risk of bias (ROB tool was used to assess the methodological quality. Outcome measurements were visual analogue scale (VAS, tenderness threshold (TT, heel tenderness index (HTI, response rate, plantar fascia thickness (PFT, hypoechogenicity and heel pad thickness (HPT. The statistical analysis was performed with software RevMan 5.2 and Stata 12.0. When I2<50%, the fixed-effects model was adopted. Otherwise the randomized-effects model was adopted. The Grading of Recommendations Assessment, Development and Evaluation (GRADE system was used to assess the quality of evidence.Five RCTs with 149 patients were identified and analyzed. Compared with palpation-guided injection, ultrasound-guided injection was superior with regard to VAS, TT, response rate, PFT and hypoechogenicity. However, there was no statistical significance between the two groups for HPT and HTI.Ultrasound-guided injection of corticosteroid tends to be more effective than palpation-guided injection. However, it needs to be confirmed by further research.

  1. Ultrasound- versus Palpation-Guided Injection of Corticosteroid for Plantar Fasciitis: A Meta-Analysis

    Science.gov (United States)

    Yu, Aixi; Qi, Baiwen

    2014-01-01

    Background It is controversial whether ultrasound-guided injection of corticosteroid is superior to palpation-guided injection for plantar fasciitis. This meta-analysis was performed to compare the effectiveness of ultrasound-guided and palpation-guided injection of corticosteroid for the treatment of plantar fasciitis. Methods Databases (MEDLINE, Cochrane library and EMBASE) and reference lists were searched from their establishment to August 30, 2013 for randomized controlled trials (RCTs) comparing ultrasound-guided with palpation-guided injection for plantar fasciitis. The Cochrane risk of bias (ROB) tool was used to assess the methodological quality. Outcome measurements were visual analogue scale (VAS), tenderness threshold (TT), heel tenderness index (HTI), response rate, plantar fascia thickness (PFT), hypoechogenicity and heel pad thickness (HPT). The statistical analysis was performed with software RevMan 5.2 and Stata 12.0. When I2<50%, the fixed-effects model was adopted. Otherwise the randomized-effects model was adopted. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was used to assess the quality of evidence. Results Five RCTs with 149 patients were identified and analyzed. Compared with palpation-guided injection, ultrasound-guided injection was superior with regard to VAS, TT, response rate, PFT and hypoechogenicity. However, there was no statistical significance between the two groups for HPT and HTI. Conclusion Ultrasound-guided injection of corticosteroid tends to be more effective than palpation-guided injection. However, it needs to be confirmed by further research. PMID:24658102

  2. Pulse-wave propagation in straight-geometry vessels for stiffness estimation: theory, simulations, phantoms and in vitro findings.

    Science.gov (United States)

    Shahmirzadi, Danial; Li, Ronny X; Konofagou, Elisa E

    2012-11-01

    Pulse wave imaging (PWI) is an ultrasound-based method for noninvasive characterization of arterial stiffness based on pulse wave propagation. Reliable numerical models of pulse wave propagation in normal and pathological aortas could serve as powerful tools for local pulse wave analysis and a guideline for PWI measurements in vivo. The objectives of this paper are to (1) apply a fluid-structure interaction (FSI) simulation of a straight-geometry aorta to confirm the Moens-Korteweg relationship between the pulse wave velocity (PWV) and the wall modulus, and (2) validate the simulation findings against phantom and in vitro results. PWI depicted and tracked the pulse wave propagation along the abdominal wall of canine aorta in vitro in sequential Radio-Frequency (RF) ultrasound frames and estimates the PWV in the imaged wall. The same system was also used to image multiple polyacrylamide phantoms, mimicking the canine measurements as well as modeling softer and stiffer walls. Finally, the model parameters from the canine and phantom studies were used to perform 3D two-way coupled FSI simulations of pulse wave propagation and estimate the PWV. The simulation results were found to correlate well with the corresponding Moens-Korteweg equation. A high linear correlation was also established between PWV² and E measurements using the combined simulation and experimental findings (R² =  0.98) confirming the relationship established by the aforementioned equation.

  3. The impact of anthropometric patient-phantom matching on organ dose: A hybrid phantom study for fluoroscopy guided interventions

    International Nuclear Information System (INIS)

    Johnson, Perry B.; Geyer, Amy; Borrego, David; Ficarrotta, Kayla; Johnson, Kevin; Bolch, Wesley E.

    2011-01-01

    Purpose: To investigate the benefits and limitations of patient-phantom matching for determining organ dose during fluoroscopy guided interventions. Methods: In this study, 27 CT datasets representing patients of different sizes and genders were contoured and converted into patient-specific computational models. Each model was matched, based on height and weight, to computational phantoms selected from the UF hybrid patient-dependent series. In order to investigate the influence of phantom type on patient organ dose, Monte Carlo methods were used to simulate two cardiac projections (PA/left lateral) and two abdominal projections (RAO/LPO). Organ dose conversion coefficients were then calculated for each patient-specific and patient-dependent phantom and also for a reference stylized and reference hybrid phantom. The coefficients were subsequently analyzed for any correlation between patient-specificity and the accuracy of the dose estimate. Accuracy was quantified by calculating an absolute percent difference using the patient-specific dose conversion coefficients as the reference. Results: Patient-phantom matching was shown most beneficial for estimating the dose to heavy patients. In these cases, the improvement over using a reference stylized phantom ranged from approximately 50% to 120% for abdominal projections and for a reference hybrid phantom from 20% to 60% for all projections. For lighter individuals, patient-phantom matching was clearly superior to using a reference stylized phantom, but not significantly better than using a reference hybrid phantom for certain fields and projections. Conclusions: The results indicate two sources of error when patients are matched with phantoms: Anatomical error, which is inherent due to differences in organ size and location, and error attributed to differences in the total soft tissue attenuation. For small patients, differences in soft tissue attenuation are minimal and are exceeded by inherent anatomical differences

  4. Ultrasound- and MRI-Guided Prostate Biopsy

    Science.gov (United States)

    ... assistance of a nurse and an MR imaging technologist. As with the ultrasound procedure, you may receive antibiotics, sedatives and pain medication before the biopsy. The MRI-guided procedure may use contrast ... A nurse or technologist will insert an intravenous (IV) catheter into a ...

  5. Settings and artefacts relevant for Doppler ultrasound in large vessel vasculitis

    DEFF Research Database (Denmark)

    Terslev, L; Diamantopoulos, A P; Døhn, U Møller

    2017-01-01

    Ultrasound is used increasingly for diagnosing large vessel vasculitis (LVV). The application of Doppler in LVV is very different from in arthritic conditions. This paper aims to explain the most important Doppler parameters, including spectral Doppler, and how the settings differ from those used...

  6. Automated 3D ultrasound elastography of the breast: a phantom validation study

    Science.gov (United States)

    Hendriks, Gijs A. G. M.; Holländer, Branislav; Menssen, Jan; Milkowski, Andy; Hansen, Hendrik H. G.; de Korte, Chris L.

    2016-04-01

    In breast cancer screening, the automated breast volume scanner (ABVS) was introduced as an alternative for mammography since the latter technique is less suitable for women with dense breasts. Although clinical studies show promising results, clinicians report two disadvantages: long acquisition times (>90 s) introducing breathing artefacts, and high recall rates due to detection of many small lesions of uncertain malignant potential. Technical improvements for faster image acquisition and better discrimination between benign and malignant lesions are thus required. Therefore, the aim of this study was to investigate if 3D ultrasound elastography using plane-wave imaging is feasible. Strain images of a breast elastography phantom were acquired by an ABVS-mimicking device that allowed axial and elevational movement of the attached transducer. Pre- and post-deformation volumes were acquired with different constant speeds (between 1.25 and 40.0 mm s-1) and by three protocols: Go-Go (pre- and post-volumes with identical start and end positions), Go-Return (similar to Go-Go with opposite scanning directions) and Control (pre- and post-volumes acquired per position, this protocol can be seen as reference). Afterwards, 2D and 3D cross-correlation and strain algorithms were applied to the acquired volumes and the results were compared. The Go-Go protocol was shown to be superior with better strain image quality (CNRe and SNRe) than Go-Return and to be similar as Control. This can be attributed to applying opposite mechanical forces to the phantom during the Go-Return protocol, leading to out-of-plane motion. This motion was partly compensated by using 3D cross-correlation. However, the quality was still inferior to Go-Go. Since these results were obtained in a phantom study with controlled deformations, the effect of possible uncontrolled in vivo tissue motion artefacts has to be addressed in future studies. In conclusion, it seems feasible to implement 3D ultrasound

  7. Hoarseness of voice after supraclavicular ultrasound-guided subclavian perivascular brachial plexus block

    Directory of Open Access Journals (Sweden)

    Monika Gupta

    2017-01-01

    Full Text Available Supraclavicular brachial plexus nerve block is ideal for surgical procedures at or distal to the elbow. Ultrasound (USG continues to grow in popularity as a method of nerve localization, and for the supraclavicular block, it has the advantage of allowing real-time visualization of the plexus, pleura, and vessels along with the needle and local anesthetic spread, but it may conversely create a false sense of security. The incidence of the recurrent laryngeal nerve (RLN block occurring with supraclavicular approach is 1.3% of patients.[10] Incidence of RLN block with USG-guided supraclavicular block is not known. In this case report, we discuss a rare complication of RLN block which occurred while performing a supraclavicular perivascular block performed under USG guidance.

  8. [Endoscopic ultrasound guided rendezvous for biliary drainage].

    Science.gov (United States)

    Knudsen, Marie Høxbro; Vilmann, Peter; Hassan, Hazem; Karstensen, John Gésdal

    2015-04-27

    Endoscopic retrograde cholangiography (ERCP) is currently standard treatment for biliary drainage. Endoscopic ultrasound guided rendezvous (EUS-RV) is a novel method to overcome an unsuccessful biliary drainage procedure. Under endoscopic ultrasound guidance a guidewire is passed via a needle from the stomach or duodenum to the common bile duct and from there on to the duodenum enabling ERCP. With a relatively high rate of success EUS-RV should be considered as an alternative to biliary drainage and surgical intervention.

  9. Transvaginal Ultrasound-Guided Biopsy of Deep Pelvic Masses: How We Do It.

    Science.gov (United States)

    Plett, Sara K; Poder, Liina; Brooks, Rebecca A; Morgan, Tara A

    2016-06-01

    The purpose of this review is to discuss the rationale and indications for transvaginal ultrasound-guided biopsy. Transvaginal ultrasound-guided biopsy can be a helpful tool for diagnosis and treatment planning in the evaluation of pelvic masses, particularly when the anatomy precludes a transabdominal or posterior transgluteal percutaneous biopsy approach. A step-by-step summary of the technique with preprocedure and postprocedure considerations is included. © 2016 by the American Institute of Ultrasound in Medicine.

  10. Adjustable guide for a testing system for reactor pressure vessels

    International Nuclear Information System (INIS)

    Seifert, W.

    1980-01-01

    The device consisting of a guide rail and a manipulator is introduced into the gap between pressure vessel wall and biological shield by means of suspending wire drums and manipulator drums. For adjustment of the device an elbow telescope is used. The guide rail is fixed to the pressure vessel wall by means of electromagnets. The movements of the manipulator with respect to the guide rail are performed with the aid of a motor. (DG) [de

  11. The transabdominal chorionic villus sampling puncture guided by color Doppler ultrasound during early pregnancy

    International Nuclear Information System (INIS)

    Liang Weixiang; Chen Zhiyi; Yuan Wenlin; Cai Kuan; Zhu Junlin; Wang Weiqun; Chen Xia

    2008-01-01

    Objective: To study the operation of chorionic villus sampling (CVS) guided by color Doppler ultrasound (CDU) via abdomen puncture during early pregnancy and investigate the advertences during the operation. Methods: CVS guided by CDU probe via abdomen puncture were operated on 28 pregnant women who had the indications of antenatal diagnosis. CDU was used to observe the implantation position of the fo1iaceous villis and help setting mark of the puncture point and puncture range on body surface before operation. The needle was punctured under real-time ultrasound guidance and villis were aspirated during the operation: The choice of the right time of puncture and the operation skills were emphasized in the study. Results: The CVS puncture approach should be set through CDU ob servation, which attend to avoid the surrounding blood vessels, intestinal canal and surrounding important organs. The puncture point should be chosen in a point where lobif0rmed villis distributed wider and with a larger scope. The operations were performed from 10 to13 weeks of pregnancy, with an average of 11 weeks. Among these 28 cases, 9.6 were successfully drawn materials in one time, 1 in twice and l failure, with the total ratio of achievement was 96.4%. For all the cases, fetal heart pulsating could be seen by real-time CDU observation fight after the operation, and no larger hematoma echo in the placental site occurred. Ultrasound reexamined one week after the operation, fetal heart pulsation could be found in all cases, and no abortion cases occurred after regular follow-up in 25 continued pregnant patients. Conclusion: Abdominal CVS puncture guided by CDU probe is conveniently operated, safe and available in clinic. It is an important method for antenatal diagnosis during early pregnancy. The puncture localization, skills and the time are the key points for the success in obtaining the materials. (authors)

  12. Ultrasound-guided antegrade pyelography of renal transplants

    International Nuclear Information System (INIS)

    Wernecke, K.; Heckemann, R.; Rehwald, U.; Ringert, R.H.; Essen Univ.

    1983-01-01

    The indications for, and technique of, ultrasound-guided antegrade pyelography of renal transplants are illustrated by eight patients. Because of the detailed anatomical information which the antegrade method provides, it is superior to other diagnostic methods for the investigation of ureteric obstruction or fistulae. The severity of renal pelvis dilatation as shown by sonography must not be taken as a criterian for the grade of obstruction, since transplants may show dilated collecting systems, even in the absence of obstruction. In our view, real time sonography with a suitable probe provides the best means of achieving successful puncture of the renal pelvis. The combination of ultrasound-guided puncture and radiological contrast examination of the ureter is the best diagnostic method available and lead, in all eight cases, to immediate and definitive treatment. (orig.)

  13. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    Science.gov (United States)

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  14. Comparison of Ultrasound-Guided and Fluoroscopy-Assisted Antegrade Common Femoral Artery Puncture Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Slattery, Michael M.; Goh, Gerard S.; Power, Sarah; Given, Mark F.; McGrath, Frank P.; Lee, Michael J., E-mail: mlee@rcsi.ie [Beaumont Hospital, Department of Radiology (Ireland)

    2015-06-15

    PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrade puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.

  15. Ultrasound-guided central venous access using Google Glass.

    Science.gov (United States)

    Wu, Teresa S; Dameff, Christian J; Tully, Jeffrey L

    2014-12-01

    The use of ultrasound during invasive bedside procedures is quickly becoming the standard of care. Ultrasound machine placement during procedures often requires the practitioner to turn their head during the procedure to view the screen. Such turning has been implicated in unintentional hand movements in novices. Google Glass is a head-mounted computer with a specialized screen capable of projecting images and video into the view of the wearer. Such technology may help decrease unintentional hand movements. Our aim was to evaluate whether or not medical practitioners at various levels of training could use Google Glass to perform an ultrasound-guided procedure, and to explore potential advantages of this technology. Forty participants of varying training levels were randomized into two groups. One group used Google Glass to perform an ultrasound-guided central line. The other group used traditional ultrasound during the procedure. Video recordings of eye and hand movements were analyzed. All participants from both groups were able to complete the procedure without difficulty. Google Glass wearers took longer to perform the procedure at all training levels (medical student year 1 [MS1]: 193 s vs. 77 s, p > 0.5; MS4: 197s vs. 91s, p ≤ 0.05; postgraduate year 1 [PGY1]: 288s vs. 125 s, p > 0.5; PGY3: 151 s vs. 52 s, p ≤ 0.05), and required more needle redirections (MS1: 4.4 vs. 2.0, p > 0.5; MS4: 4.8 vs. 2.8, p > 0.5; PGY1: 4.4 vs. 2.8, p > 0.5; PGY3: 2.0 vs. 1.0, p > 0.5). In this study, it was possible to perform ultrasound-guided procedures with Google Glass. Google Glass wearers, on average, took longer to gain access, and had more needle redirections, but less head movements were noted. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Development and Implementation of an Ultrasound-Guided Peripheral Intravenous Catheter Program for Emergency Nurses.

    Science.gov (United States)

    Edwards, Courtney; Jones, Jodi

    2018-01-01

    Emergency medical care often necessitates placement of peripheral intravenous (PIV) catheters. When traditional methods for obtaining PIV access are not successful, ultrasound guidance is a rescue technique for peripheral vascular placement that improves the quality of patient care. The aim of this training program was to develop a process where emergency nurses would be competent to perform ultrasound guided PIV to improve the quality of patient care delivered while reducing throughput time. Administrative program development required creating a nursing practice statement, procedure guideline, operational plan, and competency validation. A training program comprising both didactic and hands-on training was developed and provided by emergency medicine physicians with formal ultrasound fellowship training. In determining whether the training program was adequate in preparing the student to place an ultrasound-guided PIV, 92.9% of students "agreed" or "strongly agreed." In having confidence in their ability to obtain an ultrasound guided PIV catheter placement, 35.7% of respondents "agreed" and 64.3% "strongly agreed." In finding it difficult to be successful in achieving ultrasound guided PIV catheter placement, 71.4% of students "strongly disagreed" and 14.3% "disagreed." All students (100%) felt it was a feasible task to train nurses to successfully place ultrasound-guided PIV catheters and 71.4% of students strongly support continuing to provide this training program and competency validation. Establishment of an effective didactic and hands-on training program resulted in emergency department nurses becoming competent in placement of ultrasound guided PIV catheters to provide optimal patient care. Copyright © 2017 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.

  17. Ultrasound guided pleural biopsy in undiagnosed exudative pleural effusion patients

    Directory of Open Access Journals (Sweden)

    Adel S. Ahmed

    2016-04-01

    In conclusion: Thoracic ultrasound (TUS guided pleural biopsy had a diagnostic yield which was slightly lower but comparable to both CT guided pleural biopsy and medical thoracoscopic pleural biopsy (MT.

  18. Ultrasound-guided percutaneous transhepatic biliary drainage: Experiences in 146 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jai Keun [Sohwa Children' s Hospital, Seoul(Korea, Republic of); Yu, Jeong Sik; Kim, Ki Whang; Chung, Soo Yoon; Jeong, Mi Gyoung [Yonsei University College of Medicine, Seoul (Korea, Republic of); Choi, Deuk Lin; Kwon, Gui Hyang; Lee, Hae Kyung [Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    1999-03-15

    Percutaneous biliary drainage is an important technique for palliative therapy of obstructive biliary disease and diagnostic information. The purpose of this study is to review and evaluate the experiences of ultrasound-guided percutaneous transhepatic biliary drainage. Ultrasound-guided percutaneous transhepatic biliary drainage was performed on 146 occasions in 134 patients. The causes of biliary obstruction were: benign diseases (19 cases, 14.2%) such as bile duct stones or stricture, cholangiocarcinoma (37 cases, 27.6%), pancreatic carcinoma (35 cases, 26.1%), metastasis (22 cases, 16.5%), gall bladder cancer (14 cases, 10.4%), ampulla of Vater cancer (4 cases, 3.0%), hepatocellular carcinoma (3 cases, 2.2%). Retrospectively reviewing medical records, we found out frequency of external or external/internal biliary drainages, puncture of left or right hepatic duct, and presence of bileinfection. Ultrasound-guided percutaneous transhepatic biliary drainage was compared with conventional biliary drainage of previous reports on the basis of frequency of complications. External (124 procedures, 84.9%) and external/internal biliary drainage (22 procedures, 15.1%) were carried out by puncture of dilated right (59.6%) or left (40.4%) intrahepatic duct. Sixty-nine complications occurred in 47 patients. Catheter related complications (33/69, 47.8%) were most common: catheter dislodgement (17/69, 24.6%), malfunction (9/69, 13.1%), leakage (7/69, 10.1%). Other minor complications such as simple fever (16/69, 23.2%), cholangitis (7/69, 10.1%), hemobilia (4/69, 5.8%), biloma (2/69, 2.9%) and wound infection (1/69, 1.5%) occurred. Major complications including sepsis (4/69, 5.8%) and bile peritonitis (2/69, 2.9%) were also noted. Puncture-related complications such as hemobilia, biloma and bile peritonitis occurred in 8 cases (5.5%). Comparing with conventional X-ray guided drainage, ultrasound-guided percutaneous transhepatic biliary drainage is a safe procedure for

  19. Contrast-enhanced ultrasound-guided radiofrequency ablation in inconspicuous hepatocellular carcinoma on B-mode ultrasound.

    Science.gov (United States)

    Kim, Eui Joo; Kim, Yun Soo; Shin, Seung Kak; Kwon, Oh Sang; Choi, Duck Joo; Kim, Ju Hyun

    2017-11-01

    B-mode ultrasound (US) has difficulty targeting small hepatocellular carcinomas (HCCs) with poor conspicuity during radiofrequency ablation (RFA). Contrast-enhanced ultrasound (CEUS) can improve visualization of small or inconspicuous HCCs. This study was conducted to evaluate the effectiveness of CEUS-guided RFA electrode insertion during the arterial phase in inconspicuous HCCs. Ninety-three treatment-naïve HCCs from 80 patients treated with RFA from August 2012 to December 2014 were retrospectively reviewed. Seventy-five HCCs from 65 patients underwent B-mode US-guided RFA, and 15 HCCs from 14 patients that were inconspicuous on B-mode US underwent CEUS-guided RFA during the arterial phase after injection of sulfur hexafluoride microbubbles (SonoVue®). Technical success was assessed by contrast-enhanced computed tomography within 1 week and 3 months after the procedure. The mean size of HCCs treated with CEUS-guided RFA was smaller than that of HCCs treated with B-mode US-guided RFA (1.17±0.36 vs. 1.63±0.55 cm, p=0.003). Technical success rates of CEUS-guided RFA within 1 week and 3 months were 100% (15/15) and 93.3% (14/15), respectively. Technical success rates of B-mode US-guided RFA were 97.3% (73/75) and 94.5% (69/73), respectively. CEUS-guided RFA is highly efficacious for ablation of very small and inconspicuous HCCs.

  20. Review of magnetic resonance-guided focused ultrasound in the treatment of uterine fibroids

    Directory of Open Access Journals (Sweden)

    Pedro Felipe Magalhães Peregrino

    Full Text Available Uterine leiomyoma is the most frequently occurring solid pelvic tumor in women during the reproductive period. Magnetic resonance-guided high-intensity focused ultrasound is a promising technique for decreasing menorrhagia and dysmenorrhea in symptomatic women. The aim of this study is to review the role of Magnetic resonance-guided high-intensity focused ultrasound in the treatment of uterine fibroids in symptomatic patients. We performed a review of the MEDLINE and Cochrane databases up to April 2016. The analysis and data collection were performed using the following keywords: Leiomyoma, High-Intensity Focused Ultrasound Ablation, Ultrasonography, Magnetic Resonance Imaging, Menorrhagia. Two reviewers independently performed a quality assessment; when there was a disagreement, a third reviewer was consulted. Nineteen studies of Magnetic resonance-guided high-intensity focused ultrasound-treated fibroid patients were selected. The data indicated that tumor size was reduced and that symptoms were improved after treatment. There were few adverse effects, and they were not severe. Some studies have reported that in some cases, additional sessions of Magnetic resonance-guided high-intensity focused ultrasound or other interventions, such as myomectomy, uterine artery embolization or even hysterectomy, were necessary. This review suggests that Magnetic resonance-guided high-intensity focused ultrasound is a safe and effective technique. However, additional evidence from future studies will be required before the technique can be recommended as an alternative treatment for fibroids.

  1. Transvaginal Ultrasound-Guided Aspiration of Pelvic Abscesses

    Directory of Open Access Journals (Sweden)

    P. J. Corsi

    1999-01-01

    Full Text Available Objective: To assess the utility of a less invasive approach to the care of women with a pelvic abscess, we retrospectively reviewed the outcome of women with pelvic abscesses managed by transvaginal ultrasound-guided aspiration.

  2. Temperature dependence of acoustic harmonics generated by nonlinear ultrasound beam propagation in ex vivo tissue and tissue-mimicking phantoms.

    Science.gov (United States)

    Maraghechi, Borna; Kolios, Michael C; Tavakkoli, Jahan

    2015-01-01

    Hyperthermia is a cancer treatment technique that could be delivered as a stand-alone modality or in conjunction with chemotherapy or radiation therapy. Noninvasive and real-time temperature monitoring of the heated tissue improves the efficacy and safety of the treatment. A temperature-sensitive acoustic parameter is required for ultrasound-based thermometry. In this paper the amplitude and the energy of the acoustic harmonics of the ultrasound backscattered signal are proposed as suitable parameters for noninvasive ultrasound thermometry. A commercial high frequency ultrasound imaging system was used to generate and detect acoustic harmonics in tissue-mimicking gel phantoms and ex vivo bovine muscle tissues. The pressure amplitude and the energy content of the backscattered fundamental frequency (p1 and E1), the second (p2 and E2) and the third (p3 and E3) harmonics were detected in pulse-echo mode. Temperature was increased from 26° to 46 °C uniformly through both samples. The amplitude and the energy content of the harmonics and their ratio were measured and analysed as a function of temperature. The average p1, p2 and p3 increased by 69%, 100% and 283%, respectively as the temperature was elevated from 26° to 46 °C in tissue samples. In the same experiment the average E1, E2 and E3 increased by 163%, 281% and 2257%, respectively. A similar trend was observed in tissue-mimicking gel phantoms. The findings suggest that the harmonics generated due to nonlinear ultrasound beam propagation are highly sensitive to temperature and could potentially be used for noninvasive ultrasound tissue thermometry.

  3. Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education.

    Science.gov (United States)

    Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J A; Dandorf, Stewart J; Dunleavy, James; Viscusi, Rebecca; Amini, Richard

    2016-05-01

    Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (pcadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical

  4. A review of the recommendations governing quality assurance of ultrasound systems used for guidance in prostate brachytherapy.

    Science.gov (United States)

    Doyle, Andrea Jane; King, Deirdre M; Browne, Jacinta E

    2017-12-01

    Ultrasound guided brachytherapy for the treatment of prostate cancer has become a routine treatment option, due to many benefits including patient recovery and dose localisation [1]; however it is not clear whether the standards which govern the image quality for these systems are adequate. Upon review of the recommended standards for ultrasound systems used in prostate brachytherapy procedures, the recommended tests do not appear to be specific to the clinical application of ultrasound guided prostate brachytherapy. Rather they are generic and similar to those recommended for other clinical applications such as general abdominal scanning [2]. Furthermore, there is growing evidence that these tests should be specific to the clinical application [3,4] in order to gain meaningful data about the performance of the system for the application, and also to detect clinically relevant changes in quality control results. An additional problem is that there are no clinically relevant test phantom recommended for the quality assurance of ultrasound systems used in prostate brachytherapy. The image quality for this application of ultrasound needs to be monitored to ensure consistent levels of confidence in the procedure. This paper reviews the currently recommended test guidelines and test phantoms for ultrasound systems used in prostate brachytherapy from the different standard bodies and professional organisations. A critical analysis of those tests which are most reflective of the imaging and guidance tasks undertaken in an ultrasound guided prostate brachytherapy procedure will also be presented to inform the design of a TRUS quality assurance protocol. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  5. Transbiliary intravascular ultrasound-guided diagnostic biopsy of an inaccessible pancreatic head mass

    Directory of Open Access Journals (Sweden)

    Jeffrey Forris Beecham Chick, MD, MPH, DABR

    2017-06-01

    Full Text Available Percutaneous image-guided biopsies of pancreatic malignancies may prove challenging and nondiagnostic due to a variety of anatomic considerations. For patients with complex post-surgical anatomy, such as a Roux-en-Y gastric bypass, diagnosis via endoscopic ultrasound with fine-needle aspiration may not be possible because of an inability to reach the proximal duodenum. This report describes the first diagnostic case of transbiliary intravascular ultrasound-guided biopsy of a pancreatic head mass in a patient with prior Roux-en-Y gastric bypass for which a diagnosis could not be achieved via percutaneous and endoscopic approaches. Transbiliary intravascular ultrasound-guided biopsy resulted in a diagnosis of pancreatic adenocarcinoma, allowing the initiation of chemotherapy.

  6. Proactive error analysis of ultrasound-guided axillary brachial plexus block performance.

    LENUS (Irish Health Repository)

    O'Sullivan, Owen

    2012-07-13

    Detailed description of the tasks anesthetists undertake during the performance of a complex procedure, such as ultrasound-guided peripheral nerve blockade, allows elements that are vulnerable to human error to be identified. We have applied 3 task analysis tools to one such procedure, namely, ultrasound-guided axillary brachial plexus blockade, with the intention that the results may form a basis to enhance training and performance of the procedure.

  7. Ultrasound-guided lumpectomy of nonpalpable breast cancer versus wire-guided resection: a randomized clinical trial.

    NARCIS (Netherlands)

    Rahusen, F.D.; Bremers, A.J.A.; Fabry, H.F.; Taets van Amerongen, A.H.; Boom, R.P.; Meijer, S.

    2002-01-01

    BACKGROUND: The wire-guided excision of nonpalpable breast cancer often results in tumor resections with inadequate margins. This prospective, randomized trial was undertaken to investigate whether intraoperative ultrasound (US) guidance enables a better margin clearance than the wire-guided

  8. Ultrasound guided double injection of blood into cisterna magna: a rabbit model for treatment of cerebral vasospasm.

    Science.gov (United States)

    Chen, Yongchao; Zhu, Youzhi; Zhang, Yu; Zhang, Zixuan; Lian, Juan; Luo, Fucheng; Deng, Xuefei; Wong, Kelvin K L

    2016-02-06

    Double injection of blood into cisterna magna using a rabbit model results in cerebral vasospasm. An unacceptably high mortality rate tends to limit the application of model. Ultrasound guided puncture can provide real-time imaging guidance for operation. The aim of this paper is to establish a safe and effective rabbit model of cerebral vasospasm after subarachnoid hemorrhage with the assistance of ultrasound medical imaging. A total of 160 New Zealand white rabbits were randomly divided into four groups of 40 each: (1) manual control group, (2) manual model group, (3) ultrasound guided control group, and (4) ultrasound guided model group. The subarachnoid hemorrhage was intentionally caused by double injection of blood into their cisterna magna. Then, basilar artery diameters were measured using magnetic resonance angiography before modeling and 5 days after modeling. The depth of needle entering into cisterna magna was determined during the process of ultrasound guided puncture. The mortality rates in manual control group and model group were 15 and 23 %, respectively. No rabbits were sacrificed in those two ultrasound guided groups. We found that the mortality rate in ultrasound guided groups decreased significantly compared to manual groups. Compared with diameters before modeling, the basilar artery diameters after modeling were significantly lower in manual and ultrasound guided model groups. The vasospasm aggravated and the proportion of severe vasospasms was greater in ultrasound guided model group than that of manual group. In manual model group, no vasospasm was found in 8 % of rabbits. The ultrasound guided double injection of blood into cisterna magna is a safe and effective rabbit model for treatment of cerebral vasospasm.

  9. Evolution of Robot-assisted ultrasound-guided breast biopsy systems

    Directory of Open Access Journals (Sweden)

    Mustafa Z. Mahmoud

    2018-01-01

    Full Text Available Robot-assisted ultrasound-guided breast biopsy combines ultrasound (US imaging with a robotic system for medical interventions. This study was designed to provide a literature review of a robotic US-guided breast biopsy system to delineate its efficacious impact on current medical practice. In addition, the strengths and limitations of this approach were also addressed. Articles published in the English language between 2000 and 2016 were appraised in this review. A wide range of systems that bind robotics with US imaging and guided breast biopsy were examined in this article. The fundamental safety and real-time imaging capabilities of US, together with the accuracy and maneuverability of robotic devices, is clearly an effective association with unmatched capabilities. Numerous experimental systems have obvious benefits over old-fashioned techniques, and the future of robot-assisted US-guided breast biopsy will be characterized by increasing levels of automation, and they hold tremendous possibility to impact doctor achievement, patient recovery, and clinical management.

  10. Musculoskeletal ultrasound: how to treat calcific tendinitis of the rotator cuff by ultrasound-guided single-needle lavage technique.

    Science.gov (United States)

    Lee, Kenneth S; Rosas, Humberto G

    2010-09-01

    The purpose of this video article is to illustrate the ultrasound appearance of calcium deposition in the rotator cuff and provide a detailed step-by-step protocol for performing the ultrasound-guided single-needle lavage technique for the treatment of calcific tendinitis with emphasis on patient positioning, necessary supplies, real-time lavage technique, and steroid injection into the subacromial subdeltoid bursa. Musculoskeletal ultrasound is well established as a safe, cost-effective imaging tool in diagnosing and treating common musculoskeletal disorders. Calcific tendinitis of the rotator cuff is a common disabling cause of shoulder pain. Although most cases are self-limiting, a subset of patients is refractory to conservative therapy and requires treatment intervention. Ultrasound-guided lavage is an effective and safe minimally-invasive treatment not readily offered in the United States as an alternative to surgery, perhaps because of the limited prevalence of musculoskeletal ultrasound programs and limited training. On completion of this video article, the participant should be able to develop an appropriate diagnostic and therapeutic algorithm for the treatment of calcific tendinitis of the rotator cuff using ultrasound.

  11. Full experimental modelling of a liver tissue mimicking phantom for medical ultrasound studies employing different hydrogels.

    Science.gov (United States)

    Casciaro, Sergio; Conversano, Francesco; Musio, Stefano; Casciaro, Ernesto; Demitri, Christian; Sannino, Alessandro

    2009-04-01

    Tissue mimicking phantoms have been widely reported to be an important tool for development, optimisation and performance testing of ultrasound-based diagnostic techniques. In particular, modern applications of tissue mimicking phantoms often include characterisation of the nonlinear behaviour of experimental ultrasound contrast agents. In such cases, the tissue-mimicking materials should be chosen not only based on the values of their density, speed of sound and attenuation coefficient, but also considering their effect on the appearance of "native harmonics" due to nonlinear distortion of ultrasound signal during propagation. In a previous paper it was demonstrated that a cellulose-based hydrogel is suitable to simulate nonlinear acoustical behaviour of liver tissue for thicknesses up to 8 cm. In this paper we present the experimental characterisation of the nonlinear acoustical behaviour of a different polyethylene glycol diacrylate (PEGDA)-based hydrogel, in order to assess whether and how it can improve the performances and overcome some limitations of the cellulose-based hydrogel as liver tissue-mimicking material. Samples of pig liver tissue, cellulose-based hydrogel and PEGDA-based hydrogel were insonified in a through-transmission set-up, employing 2.25-MHz pulses with different mechanical index (MI) values. Second harmonic and first harmonic amplitudes were extracted from the spectra of received signals and their difference was then used to compare sample behaviours. Obtained results show how a new more accurate and combined experimental model of linear and nonlinear acoustical behaviour of liver tissue is feasible. In fact, a further confirmation of the cellulose-based hydrogel effectiveness to precisely simulate the liver tissue for penetration depths up to 8 cm was provided, and it was also shown that the employment of the PEGDA-based hydrogel can extend the range of useful tissue-mimicking material thicknesses up to 11 cm, moreover allowing a

  12. Quantitative measurement of portal blood flow by magnetic resonance phase contrast. Comparative study of flow phantom and Doppler ultrasound in vivo

    International Nuclear Information System (INIS)

    Tsunoda, Masatoshi; Kimoto, Shin; Hamazaki, Keisuke; Takeda, Yoshihiro; Hiraki, Yoshio.

    1994-01-01

    A non-invasive method for measuring portal blood flow by magnetic resonance (MR) phase contrast was evaluated in a flow phantom and 20 healthy volunteers. In a flow phantom study, the flow volumes and mean flow velocities measured by MR phase contrast showed close correlations with those measured by electromagnetic flow-metry. In 20 healthy volunteers, the cross-sectional areas, flow volumes and mean flow velocities measured by MR phase contrast correlated well with those measured by the Doppler ultrasound method. Portal blood flow averaged during the imaging time could be measured under natural breathing conditions by using a large number of acquisitions without the limitations imposed on the Doppler ultrasound method. MR phase contrast is considered to be useful for the non-invasive measurement of portal blood flow. (author)

  13. Automated 3D ultrasound elastography of the breast: a phantom validation study

    International Nuclear Information System (INIS)

    Hendriks, Gijs A G M; Holländer, Branislav; Menssen, Jan; Hansen, Hendrik H G; De Korte, Chris L; Milkowski, Andy

    2016-01-01

    In breast cancer screening, the automated breast volume scanner (ABVS) was introduced as an alternative for mammography since the latter technique is less suitable for women with dense breasts. Although clinical studies show promising results, clinicians report two disadvantages: long acquisition times (>90 s) introducing breathing artefacts, and high recall rates due to detection of many small lesions of uncertain malignant potential. Technical improvements for faster image acquisition and better discrimination between benign and malignant lesions are thus required. Therefore, the aim of this study was to investigate if 3D ultrasound elastography using plane-wave imaging is feasible. Strain images of a breast elastography phantom were acquired by an ABVS-mimicking device that allowed axial and elevational movement of the attached transducer. Pre- and post-deformation volumes were acquired with different constant speeds (between 1.25 and 40.0 mm s −1 ) and by three protocols: Go–Go (pre- and post-volumes with identical start and end positions), Go–Return (similar to Go–Go with opposite scanning directions) and Control (pre- and post-volumes acquired per position, this protocol can be seen as reference). Afterwards, 2D and 3D cross-correlation and strain algorithms were applied to the acquired volumes and the results were compared. The Go–Go protocol was shown to be superior with better strain image quality (CNR e and SNR e ) than Go–Return and to be similar as Control. This can be attributed to applying opposite mechanical forces to the phantom during the Go–Return protocol, leading to out-of-plane motion. This motion was partly compensated by using 3D cross-correlation. However, the quality was still inferior to Go–Go. Since these results were obtained in a phantom study with controlled deformations, the effect of possible uncontrolled in vivo tissue motion artefacts has to be addressed in future studies. In conclusion, it seems feasible to

  14. Ultrasound-guided genitourinary interventions: principles and techniques

    Directory of Open Access Journals (Sweden)

    Byung Kwan Park

    2017-10-01

    Full Text Available Ultrasound (US is often used to guide various interventional procedures in the genitourinary (GU tract because it can provide real-time imaging without any radiation hazard. Moreover, US can clearly visualize the pathway of an aspiration or biopsy needle to ensure the safety of the intervention. US guidance also helps clinicians to access lesions via the transabdominal, transhepatic, transvaginal, transrectal, and transperineal routes. Hence, US-guided procedures are useful for radiologists who wish to perform GU interventions. However, US-guided procedures and interventions are difficult for beginners because they involve a steep initial learning curve. The purpose of this review is to describe the basic principles and techniques of US-guided GU interventions.

  15. Ultrasound-guided genitourinary interventions: principles and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byung Kwan [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-10-15

    Ultrasound (US) is often used to guide various interventional procedures in the genitourinary (GU) tract because it can provide real-time imaging without any radiation hazard. Moreover, US can clearly visualize the pathway of an aspiration or biopsy needle to ensure the safety of the intervention. US guidance also helps clinicians to access lesions via the transabdominal, transhepatic, transvaginal, transrectal, and transperineal routes. Hence, US-guided procedures are useful for radiologists who wish to perform GU interventions. However, US-guided procedures and interventions are difficult for beginners because they involve a steep initial learning curve. The purpose of this review is to describe the basic principles and techniques of US-guided GU interventions.

  16. Ultrasound-guided forceps for pleural biopsy

    Directory of Open Access Journals (Sweden)

    Gamal Agmy

    2014-04-01

    Clinical implications: Ultrasound-guided forceps for pleural biopsy can overcome many of the limitations of the conventional needle biopsy procedures, provides multiple biopsy specimens of the parietal pleura that are inaccessible to the biopsy needle, and can be carried out easily and safely even in sick and obese patients. The diagnostic yield is nearly similar to thoracoscopy.

  17. A study of magnification effect to precision of computerized diameter measurement of a 3-mm vessel phantom in cineangiograms

    International Nuclear Information System (INIS)

    Yanagihara, Yoshio; Sugahara, Tetsuo; Sugimoto, Naozou; Fukunishi, Yasunobu.

    1994-01-01

    To estimate influence of magnification on digitizing to Precision of computerized measurement of coronary vessel diameter, the two measurement methods, i.e., a combined filter and Entropy filter, were applied to magnified images (x1-x6) of cineangiograms radiographed for a 3-mm vessel phantom. In conclusion, the desirable precision in clinical use, we thought, was obtainable at the magnification of x3 to x4. (author)

  18. Significance of 'Bridging vessel sign' on color Doppler ultrasound in diagnosis of uterine subserosal leiomyoma

    International Nuclear Information System (INIS)

    Lee, Jin Hee; Lee, Jung Hee; Sohn, Chul Ho; Woo, Seung Koo; Kim, Jung Sik

    2002-01-01

    To evaluate the usefulness of the 'bridging vessel sign' in differentiating uterine subserosal leiomyoma from other pelvic masses mimicking leiomyoma on color Doppler ultrasound. Histologically (n=58) and clinically (n=1) proven 59 masses from 55 women were included in this study. Histologic diagnoses included leiomyoma (n=32) and various kinds of other masses (n=27). On gray scale ultrasound, the size of tumor and presence of the ovaries were recorded. On color Doppler ultrasound, the presence of 'bridging vessel sign', which was defined as a linear vessel demonstrated between the mass and the uterus was documented. Uterine subserosal leiomyoma was diagnosed on the basis of finding this sign, and the diagnostic accuracy of this sign in differentiating subserosal leiomyoma from other pelvic tumors was calculated. In addition, the diagnostic accuracy of this sign combined with the visibility of theopsilateral ovary was compared. The size of subserosal leiomyomas ranged from 4.2 to 22.1 cm (mean, 8.3 cm) while the size of other pelvic masses, from 4.6 to 21.5 cm (mean, 9.6 cm). The 'bridging vessel sign' was demonstrated in thirty of 32 leiomyomas and in three of 27 other pelvis masses. The sensitivity, specificity, accuracy, positive predictive value, and negative value of the 'bridging vessel sign' in the diagnosis of subserosal leiomyoma were 93.8%, 99.9%, 91.5%, 90.9% and 92.3%, respectively. The detection of the ipsilateral ovary was possible in 14 of 30 women with leiomyomas and in four of 25 women with other pelvic masses. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of this finding in the diagnosis of subserosal leiomyoma were 46.7%, 84.0%, 63.6%, 77.8%, and 56.8%, respectively. 'Bridging vessel sign' can be an useful finding in the differential diagnosis of subserosal leiomyomas from other pelvic masses mimicking leiomyoma.

  19. Endoscopic ultrasound-guided transmural drainage of postoperative pancreatic collections.

    Science.gov (United States)

    Tilara, Amy; Gerdes, Hans; Allen, Peter; Jarnagin, William; Kingham, Peter; Fong, Yuman; DeMatteo, Ronald; D'Angelica, Michael; Schattner, Mark

    2014-01-01

    Pancreatic leak is a major cause of morbidity after pancreatectomy. Traditionally, peripancreatic fluid collections have been managed by percutaneous or operative drainage. Data for endoscopic ultrasound (EUS)-guided drainage of postoperative fluid collections are limited. Here we report on the safety, efficacy, and timing of EUS-guided drainage of postoperative peripancreatic collections. This is a retrospective review of 31 patients who underwent EUS-guided drainage of fluid collections after pancreatic resection. Technical success was defined as successful transgastric deployment of at least one double pigtail plastic stent. Clinical success was defined as resolution of the fluid collection on follow-up CT scan and resolution of symptoms. Early drainage was defined as initial transmural stent placement within 30 days after surgery. Endoscopic ultrasound-guided drainage was performed effectively with a technical success rate of 100%. Clinical success was achieved in 29 of 31 patients (93%). Nineteen of the 29 patients (65%) had complete resolution of their symptoms and collection with the first endoscopic procedure. Repeat drainage procedures, including some with necrosectomy, were required in the remaining 10 patients, with eventual resolution of collection and symptoms. Two patients who did not achieve durable clinical success required percutaneous drainage by interventional radiology. Seventeen (55%) of 31 patients had successful early drainage completed within 30 days of their operation. Endoscopic ultrasound-guided drainage of fluid collections after pancreatic resection is safe and effective. Early drainage (collections was not associated with increased complications in this series. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Minimally Invasive Ultrasound-Guided Carpal Tunnel Release: Preliminary Clinical Results.

    Science.gov (United States)

    Henning, P Troy; Yang, Lynda; Awan, Tariq; Lueders, Daniel; Pourcho, Adam M

    2018-04-02

    Ultrasound-guided carpal tunnel release was performed on 14 patients (18 wrists) using dynamic expansion of the transverse safe zone. Our patient population included able-bodied patients and those with impairments. The first 8 cases (12 wrists) underwent the procedure in an operating room, the remainder in an outpatient setting. No complications occurred, and all patients were able to immediately resume use of their hands without therapy. Improvements in the Quick Form of the Disabilities of the Arm, Shoulder, and Hand Index and Boston Carpal Tunnel Questionnaire at 3 months were comparable to results reported with mini-open and endoscopic release. Our results show that ultrasound-guided carpal tunnel release can be safely and effectively performed in an outpatient setting. © 2018 by the American Institute of Ultrasound in Medicine.

  1. Measurement of cone beam CT coincidence with megavoltage isocentre and image sharpness using the QUASAR Penta-Guide phantom.

    Science.gov (United States)

    Sykes, J R; Lindsay, R; Dean, C J; Brettle, D S; Magee, D R; Thwaites, D I

    2008-10-07

    For image-guided radiotherapy (IGRT) systems based on cone beam CT (CBCT) integrated into a linear accelerator, the reproducible alignment of imager to x-ray source is critical to the registration of both the x-ray-volumetric image with the megavoltage (MV) beam isocentre and image sharpness. An enhanced method of determining the CBCT to MV isocentre alignment using the QUASAR Penta-Guide phantom was developed which improved both precision and accuracy. This was benchmarked against our existing method which used software and a ball-bearing (BB) phantom provided by Elekta. Additionally, a method of measuring an image sharpness metric (MTF(50)) from the edge response function of a spherical air cavity within the Penta-Guide phantom was developed and its sensitivity was tested by simulating misalignments of the kV imager. Reproducibility testing of the enhanced Penta-Guide method demonstrated a systematic error of <0.2 mm when compared to the BB method with near equivalent random error (s=0.15 mm). The mean MTF(50) for five measurements was 0.278+/-0.004 lp mm(-1) with no applied misalignment. Simulated misalignments exhibited a clear peak in the MTF(50) enabling misalignments greater than 0.4 mm to be detected. The Penta-Guide phantom can be used to precisely measure CBCT-MV coincidence and image sharpness on CBCT-IGRT systems.

  2. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    Science.gov (United States)

    Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun

    2017-11-09

    Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P 20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.

  3. Effects of line fiducial parameters and beamforming on ultrasound calibration.

    Science.gov (United States)

    Ameri, Golafsoun; Baxter, John S H; McLeod, A Jonathan; Peters, Terry M; Chen, Elvis C S

    2017-01-01

    Ultrasound (US)-guided interventions are often enhanced via integration with an augmented reality environment, a necessary component of which is US calibration. Calibration requires the segmentation of fiducials, i.e., a phantom, in US images. Fiducial localization error (FLE) can decrease US calibration accuracy, which fundamentally affects the total accuracy of the interventional guidance system. Here, we investigate the effects of US image reconstruction techniques as well as phantom material and geometry on US calibration. It was shown that the FLE was reduced by 29% with synthetic transmit aperture imaging compared with conventional B-mode imaging in a Z-bar calibration, resulting in a 10% reduction of calibration error. In addition, an evaluation of a variety of calibration phantoms with different geometrical and material properties was performed. The phantoms included braided wire, plastic straws, and polyvinyl alcohol cryogel tubes with different diameters. It was shown that these properties have a significant effect on calibration error, which is a variable based on US beamforming techniques. These results would have important implications for calibration procedures and their feasibility in the context of image-guided procedures.

  4. The clinical value of trans-vaginal ultrasound-guided puncture in the treatment of pelvic abscess

    International Nuclear Information System (INIS)

    Wang Ping; Gong Wei

    2008-01-01

    Objective: To investigate the clinical value of trans-vaginal ultrasound-guided (TVS) puncture in the treatment of pelvic abscess. Methods 30 cases with pelvic abscess were treated by transvaginal ultrasound-guided puncture. The long-dated effects were followed-up. Results: 29 cases were cured by TVS puncture. Operation was performed in 1 patient because of invalid effect. The cure rate was 97%. Conclusion: Ultrasound-guided puncture is a safe and convenient method in the treatment of pelvic abscess. (authors)

  5. Ultrasound guided local steroid injection versus extracorporeal ...

    African Journals Online (AJOL)

    Nayera Saber

    2011-12-17

    Dec 17, 2011 ... Results: There was a statistically significant reduction in plantar fascia .... Several previous studies evaluate the effects of either local ... The choice of ultrasound guided technique of steroid injection was related to the accuracy of application and supe- ..... chronic proximal plantar fasciitis: a meta analysis.

  6. Biopsy guided by real-time sonography fused with MRI: a phantom study

    DEFF Research Database (Denmark)

    Ewertsen, C.; Grossjohann, Hanne Sønder; Nielsen, Kristina Rue

    2008-01-01

    OBJECTIVE: The purpose of our study was to test the accuracy of sonographically guided biopsies in a phantom of structures not visible on sonography but shown on MRI by using commercially available sonography systems with image fusion software. MATERIALS AND METHODS: A previously recorded MRI...

  7. Calibrating Doppler imaging of preterm intracerebral circulation using a microvessel flow phantom

    Directory of Open Access Journals (Sweden)

    Fleur A. Camfferman

    2015-01-01

    Full Text Available Introduction. Preterm infants are born during critical stages of brain development, in which the adaptive capacity of the fetus to extra-uterine environment is limited. Inadequate brain perfusion has been directly linked to preterm brain damage. Advanced high-frequency ultrasound probes and processing algorithms allow visualization of microvessels and depiction of regional variation. To assess whether visualization and flow velocity estimates of preterm cerebral perfusion using Doppler techniques is accurate, we conducted an in vitro experiment using a microvessel flow phantom.Materials and Methods. An in-house developed flow phantom containing two microvessels (inner diameter 200 and 700 microns with attached syringe pumps, filled with blood-mimicking fluid, was used to generate non-pulsatile perfusion of variable flow. Measurements were performed using an Esaote MyLab70 scanner.Results. Microvessel mimicking catheters with velocities as low as 1cm/sec were adequately visualized with a linear ultrasound probe. With a convex probe velocities <2 cm/sec could not be depicted. Within settings, velocity and diameter measurements were highly reproducible (intra class correlation 0.997 (95% CI 0.996-0.998 and 0.914 (0.864-0.946. Overall, mean velocity was overestimated up to 3-fold, especially in high velocity ranges. Significant differences were seen in velocity measurements when using steer angle correction and in vessel diameter estimation (p<0.05.Conclusion. Visualization of microvessel size catheters mimicking small brain vessels is feasible. Reproducible velocity and diameter results can be obtained, although important overestimation of the values is observed. Before velocity estimates of microcirculation can find its use in clinical practice, calibration of the ultrasound machine for any specific Doppler purpose is essential. The ultimate goal is to develop a sonographic tool that can be used for objective study of regional perfusion in routine

  8. Reproducibility of phantom-based quality assurance parameters in real-time ultrasound imaging.

    Science.gov (United States)

    Sipilä, Outi; Blomqvist, Päivi; Jauhiainen, Mervi; Kilpeläinen, Tiina; Malaska, Paula; Mannila, Vilma; Vinnurva-Jussila, Tuula; Virsula, Sari

    2011-07-01

    In a large radiological center, the ultrasound (US) quality assurance (QA) program involves several professionals. Although the operator and the parameters utilized can contribute to the results, the selected QA parameters should still reflect the quality of the US scanner, not the measuring process. To evaluate the reproducibility of recommended phantom-based US QA parameters in a realistic environment. Six sonographers measured six high-end US scanners with 20 transducers using a general purpose phantom. Every transducer was measured altogether seven times, using one frequency per transducer. The QA parameters studied were homogeneity, visualization depth, vertical and horizontal distance measurements, axial and lateral resolution, and the correct visibility of anechoic and high-contrast masses. The evaluation of the homogeneity was based on visual observations. Inter-observer interquartile ranges were computed for the grading of the masses. For the other QA parameters, the mean inter- and intra-observer coefficients of variation (CoV) were calculated. In addition, the symmetry of the reverberations when imaging air with a clean transducer was checked. The mean inter-observer CoVs were: visualization depth 11 ± 4%, vertical distance 1.7 ± 0.4%, horizontal distance 1.4 ± 0.6%, axial resolution 22 ± 7%, and lateral resolution 16 ± 8%. The mean intra-observer values were about half of these values with similar standard deviations. The visual evaluation of the homogeneity and the symmetry of the reverberations produced false-positive findings in 5% of the cases, but were found useful in detecting a defective transducer. The grading of the masses had mean interquartile ranges of 20-30% of the grading scale. The inter-observer variability in measuring phantom-based QA parameters can be relatively high. This should be considered when implementing a phantom-based QA protocol and evaluating the results.

  9. Measurement of cone beam CT coincidence with megavoltage isocentre and image sharpness using the QUASAR(TM) Penta-Guide phantom

    International Nuclear Information System (INIS)

    Sykes, J R; Lindsay, R; Dean, C J; Thwaites, D I; Brettle, D S; Magee, D R

    2008-01-01

    For image-guided radiotherapy (IGRT) systems based on cone beam CT (CBCT) integrated into a linear accelerator, the reproducible alignment of imager to x-ray source is critical to the registration of both the x-ray-volumetric image with the megavoltage (MV) beam isocentre and image sharpness. An enhanced method of determining the CBCT to MV isocentre alignment using the QUASAR(TM) Penta-Guide phantom was developed which improved both precision and accuracy. This was benchmarked against our existing method which used software and a ball-bearing (BB) phantom provided by Elekta. Additionally, a method of measuring an image sharpness metric (MTF 50 ) from the edge response function of a spherical air cavity within the Penta-Guide phantom was developed and its sensitivity was tested by simulating misalignments of the kV imager. Reproducibility testing of the enhanced Penta-Guide method demonstrated a systematic error of 50 for five measurements was 0.278 ± 0.004 lp mm -1 with no applied misalignment. Simulated misalignments exhibited a clear peak in the MTF 50 enabling misalignments greater than 0.4 mm to be detected. The Penta-Guide phantom can be used to precisely measure CBCT-MV coincidence and image sharpness on CBCT-IGRT systems

  10. Ultrasound-guided removal of Implanon devices.

    LENUS (Irish Health Repository)

    Persaud, T

    2008-11-01

    Our study has shown that ultrasound-guided localisation and removal of Implanon rods is safe, practical and highly successful. Over a 4-year period, 119 patients had successful, uncomplicated removal of their subdermal devices.The technique is particularly useful for removal of the device when it is not palpable or when an attempt at removal of a palpable device has not been successful.

  11. Two-dimensional mapping of needle visibility with linear and curved array for ultrasound-guided interventional procedure

    Science.gov (United States)

    Susanti, Hesty; Suprijanto, Kurniadi, Deddy

    2018-02-01

    Needle visibility in ultrasound-guided technique has been a crucial factor for successful interventional procedure. It has been affected by several factors, i.e. puncture depth, insertion angle, needle size and material, and imaging technology. The influences of those factors made the needle not always well visible. 20 G needles of 15 cm length (Nano Line, facet) were inserted into water bath with variation of insertion angles and depths. Ultrasound measurements are performed with BK-Medical Flex Focus 800 using 12 MHz linear array and 5 MHz curved array in Ultrasound Guided Regional Anesthesia mode. We propose 3 criteria to evaluate needle visibility, i.e. maximum intensity, mean intensity, and the ratio between minimum and maximum intensity. Those criteria were then depicted into representative maps for practical purpose. The best criterion candidate for representing the needle visibility was criterion 1. Generally, the appearance pattern of the needle from this criterion was relatively consistent, i.e. for linear array, it was relatively poor visibility in the middle part of the shaft, while for curved array, it is relatively better visible toward the end of the shaft. With further investigations, for example with the use of tissue-mimicking phantom, the representative maps can be built for future practical purpose, i.e. as a tool for clinicians to ensure better needle placement in clinical application. It will help them to avoid the "dead" area where the needle is not well visible, so it can reduce the risks of vital structures traversing and the number of required insertion, resulting in less patient morbidity. Those simple criteria and representative maps can be utilized to evaluate general visibility patterns of the needle in vast range of needle types and sizes in different insertion media. This information is also important as an early investigation for future research of needle visibility improvement, i.e. the development of beamforming strategies and

  12. Ultrasound Guided Nerve Root Injection in Patients with Cervical Spondylytic Radicular Pain

    Directory of Open Access Journals (Sweden)

    LT Choong

    2009-05-01

    Full Text Available Selective cervical nerve root injection using a mixture of corticosteroid and lignocaine is a treatment option for managing cervical radiculopathic pain. The procedure is usually performed under image guided fluoroscopy or Computerized Tomograhy. Ultrasound-guided cervical nerve root block does not expose the patients and personnel to radiation. During injection, the fluid is mostly visualized in a real-time fashion. This retrospective study reviewed the effectiveness of ultrasound in guiding cervical peri-radicular injection for pain relief in patients with recalcitrant cervical radiculopathy. There were no complications reported in this series.

  13. Ultrasound guided pO2 measurement of breast cancer reoxygenation after neoadjuvant chemotherapy and hyperthermia treatment.

    Science.gov (United States)

    Vujaskovic, Z; Rosen, E L; Blackwell, K L; Jones, E L; Brizel, D M; Prosnitz, L R; Samulski, T V; Dewhirst, M W

    2003-01-01

    The objective of this study was to determine whether neoadjuvant chemotherapy in combination with hyperthermia (HT) would improve oxygenation in locally advanced breast tumours. The study describes a new optimized ultrasound guided technique of pO2 measurement using Eppendorf polarographic oxygen probes in 18 stage IIB-III breast cancer patients. Prior to treatment, tumour hypoxia (median pO2pO2=3.2 mmHg). Seven patients had well oxygenated tumours (median pO2 of 48.3 mmHg). Eight patients with hypoxic tumours prior to treatment had a significant improvement (p=0.0008) in tumour pO2 after treatment (pO2 increased to 19.2 mmHg). In three patients, tumours remained hypoxic (average median pO2=4.5 mmHg). The advantages of the ultrasound guided pO2 probe are in the accuracy of the Eppendorf electrode placement in tumour tissue, the ability to monitor electrode movement through the tumour tissue during the measurement and the ability to avoid electrode placement near or in large blood vessels by using colour Doppler imaging. The results of this preliminary study suggest that the combination of neoadjuvant chemotherapy and hyperthermia improves oxygenation in locally advanced breast tumours that are initially hypoxic.

  14. Streaming flow from ultrasound contrast agents by acoustic waves in a blood vessel model.

    Science.gov (United States)

    Cho, Eunjin; Chung, Sang Kug; Rhee, Kyehan

    2015-09-01

    To elucidate the effects of streaming flow on ultrasound contrast agent (UCA)-assisted drug delivery, streaming velocity fields from sonicated UCA microbubbles were measured using particle image velocimetry (PIV) in a blood vessel model. At the beginning of ultrasound sonication, the UCA bubbles formed clusters and translated in the direction of the ultrasound field. Bubble cluster formation and translation were faster with 2.25MHz sonication, a frequency close to the resonance frequency of the UCA. Translation of bubble clusters induced streaming jet flow that impinged on the vessel wall, forming symmetric vortices. The maximum streaming velocity was about 60mm/s at 2.25MHz and decreased to 15mm/s at 1.0MHz for the same acoustic pressure amplitude. The effect of the ultrasound frequency on wall shear stress was more noticeable. Maximum wall shear stress decreased from 0.84 to 0.1Pa as the ultrasound frequency decreased from 2.25 to 1.0MHz. The maximum spatial gradient of the wall shear stress also decreased from 1.0 to 0.1Pa/mm. This study showed that streaming flow was induced by bubble cluster formation and translation and was stronger upon sonication by an acoustic wave with a frequency near the UCA resonance frequency. Therefore, the secondary radiant force, which is much stronger at the resonance frequency, should play an important role in UCA-assisted drug delivery. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Ultrasound-Guided Intervention for Treatment of Trigeminal Neuralgia: An Updated Review of Anatomy and Techniques

    Directory of Open Access Journals (Sweden)

    Abdallah El-Sayed Allam

    2018-01-01

    Full Text Available Orofacial myofascial pain is prevalent and most often results from entrapment of branches of the trigeminal nerves. It is challenging to inject branches of the trigeminal nerve, a large portion of which are shielded by the facial bones. Bony landmarks of the cranium serve as important guides for palpation-guided injections and can be delineated using ultrasound. Ultrasound also provides real-time images of the adjacent muscles and accompanying arteries and can be used to guide the needle to the target region. Most importantly, ultrasound guidance significantly reduces the risk of collateral injury to vital neurovascular structures. In this review, we aimed to summarize the regional anatomy and ultrasound-guided injection techniques for the trigeminal nerve and its branches, including the supraorbital, infraorbital, mental, auriculotemporal, maxillary, and mandibular nerves.

  16. Medial approach of ultrasound-guided costoclavicular plexus block and its effects on regional perfussion.

    Science.gov (United States)

    Nieuwveld, D; Mojica, V; Herrera, A E; Pomés, J; Prats, A; Sala-Blanch, X

    2017-04-01

    Ultrasound-guided infraclavicular block in the costoclavicular space located between the clavicle and the first rib, reaches the secondary trunks when they are clustered together and lateral to the axillary artery. This block is most often performed through a lateral approach, the difficulty being finding the coracoid process an obstacle and guiding the needle towards the vessels and pleura. A medial approach, meaning from inside to outside, will avoid these structures. Traditionally the assessment of a successful block is through motor or sensitive responses but a sympathetic fibre block can also be evaluated measuring the changes in humeral artery blood flow, skin temperature and/or perfusion index. To describe the medial approach of the ultrasound-guided costoclavicular block evaluating its development by motor and sensitive response and measurement of sympathetic changes. Description of the technique and administration of 20ml of contrast in a fresh cadaver model, evaluating the distribution with CT-scan and sagittal sections of the anatomic piece. Subsequently in a clinical phase, including 11 patients, we evaluated the establishment of motor, sensitive and sympathetic blocks. We evaluated the sympathetic changes reflected by humeral artery blood flow, skin temperature and distal perfusion index. In the anatomical model the block was conducted without difficulties, showing an adequate periclavicular distribution of the contrast in the CT-scan and in sagittal sections, reaching the interscalenic space as far as the secondary trunks. Successful blocks were observed in 91% of patients after 25minutes. All the parameters reflecting sympathetic block increased significantly. The humeral artery blood flow showed an increase from 108 ± 86 to 188±141ml/min (P=.05), skin temperature from 32.1±2 to 32.8±9°C (P=.03) and perfusion index from 4±3 to 9±5 (P=.003). The medial approach of the ultrasound-guided costoclavicular block is anatomically feasible, with high

  17. Pre-puncture ultrasound guided epidural insertion before vaginal delivery.

    Science.gov (United States)

    Nassar, Mahmoud; Abdelazim, Ibrahim A

    2015-10-01

    Palpation method is widely used in clinical practice to identify the puncture site during combined spinal-epidural (CSE) blocks. Tuffier's line, is an anatomical landmark between two iliac crests (inter-cristal), which is widely used to identify the puncture site during CSE blocks is not always an indicator for specific vertebral level or inter-vertebral space. One hundred and Ten (110) women were scheduled for normal vaginal delivery and were randomized into two equal groups; palpation group and an ultrasound guided group to detect the efficacy of puncture ultrasound before CSE blocks to increase chances of successful CSE procedure on the first attempt and to reduce the number of attempts or punctures during insertion of CSE catheter. There were no significant differences between two studied groups regarding; maternal age, weight and height, while, there was a significant difference between two studied groups regarding; parity. Percentage of successful CSE procedure on the first attempt was significantly higher (67.27%) in ultrasound compared to palpation group (40%). Number of punctures (attempts) were significantly less in ultrasound (1.2 ± 0.6) compared to palpation group (2.3 ± 0.8) and the number of redirections was also significantly less in ultrasound (1.4 ± 0.5) compared to palpation group (2.8 ± 1.6). Although, time to identify puncture site was significantly longer in ultrasound compared to palpation group and total procedure time was longer in ultrasound (9.1 ± 1.5 min) compared to palpation group (6.2 ± 1.2 min), there was no significant difference between two studied groups regarding; time to identify puncture site and total procedure time. Two cases of dural puncture in palpation versus no cases in ultrasound group and two cases of intravascular catheter placement (one in each group), with no significant difference between two groups. Pre- puncture ultrasound guided epidural insertion before vaginal delivery, increases the chance of a

  18. Ultrasound-Guided Percutaneous Dilational Tracheostomy: A Systematic Review of Randomized Controlled Trials and Meta-Analysis.

    Science.gov (United States)

    Gobatto, André L N; Besen, Bruno A M P; Cestari, Mino; Pelosi, Paolo; Malbouisson, Luiz M S

    2018-01-01

    Percutaneous dilational tracheostomy (PDT) is a common and increasingly used procedure in the intensive care unit (ICU). It is usually performed with bronchoscopy guidance. Ultrasound has emerged as a useful tool in order to assist PDT, potentially improving its success rate and reducing procedural-related complications. To investigate whether the ultrasound-guided PDT is equivalent or superior to the bronchoscopy-guided or anatomical landmarks-guided PDT with regard to procedural-related and clinical complications. A systematic review of randomized clinical trials was conducted comparing an ultrasound-guided PDT to the control groups (either a bronchoscopy-guided PDT or an anatomical landmark-guided PDT) in patients undergoing a PDT in the ICU. The primary outcome was the incidence of major procedural-related and clinical complication rates. The secondary outcome was the incidence of minor complication rates. Random-effect meta-analyzes were used to pool the results. Four studies fulfilled the inclusion criteria and they were analyzed. The studies included 588 participants. There were no differences in the major complication rates between the patients who were assigned to the ultrasound-guided PDT when compared to the control groups (pooled risk ratio [RR]: 0.48; 95% confidence interval [CI]: 0.13-1.71, I 2 = 0%). The minor complication rates were not different between the groups, but they had a high heterogeneity (pooled RR: 0.49; 95% CI 0.16-1.50; I 2 = 85%). The sensitivity analyzes that only included the randomized controlled trials that used a landmark-guided PDT as the control group showed lower rates of minor complications in the ultrasound-guided PDT group (pooled RR: 0.55; 95% CI: 0.31-0.98, I 2 = 0%). The ultrasound-guided PDT seems to be safe and it is comparable to the bronchoscopy-guided PDT regarding the major and minor procedural-related or clinical complications. It also seems to reduce the minor complications when compared to the anatomical

  19. Ultrasound-guided high-intensity focused ultrasound treatment for abdominal wall endometriosis: Preliminary results

    International Nuclear Information System (INIS)

    Wang Yang; Wang Wei; Wang Longxia; Wang Junyan; Tang Jie

    2011-01-01

    Purpose: To evaluate the safety and therapeutic efficacy of ultrasound (US)-guided high-intensity focused ultrasound (HIFU) ablation for the treatment of abdominal wall endometriosis (AWE). Materials and methods: Twenty-one consecutive patients with AWE were treated as outpatients by US-guided HIFU ablation under conscious sedation. The median size of the AWE was 2.4 cm (range 1.0-5.3 cm). An acoustic power of 200-420 W was used, intermittent HIFU exposure of 1 s was applied. Treatment was considered complete when the entire nodule and its nearby 1 cm margin become hyperechoic on US. Pain relief after HIFU ablation was observed and the treated nodule received serial US examinations during follow-up. Results: All AWE was successfully ablated after one session of HIFU ablation, the ablation time lasted for 5-48 min (median 13 min), no major complications occurred. The cyclic pain disappeared in all patients during a mean follow-up of 18.7 months (range 3-31 months). The treated nodules gradually shank over time, 16 nodules became unnoticeable on US during follow-up. Conclusion: US-guided HIFU ablation appears to be safe and effective for the treatment of AWE.

  20. Ultrasound-guided high-intensity focused ultrasound treatment for abdominal wall endometriosis: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yang [Department of Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China); Wang Wei, E-mail: wangyang301301@yahoo.com.cn [Department of Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China); Wang Longxia; Wang Junyan; Tang Jie [Department of Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing 100853 (China)

    2011-07-15

    Purpose: To evaluate the safety and therapeutic efficacy of ultrasound (US)-guided high-intensity focused ultrasound (HIFU) ablation for the treatment of abdominal wall endometriosis (AWE). Materials and methods: Twenty-one consecutive patients with AWE were treated as outpatients by US-guided HIFU ablation under conscious sedation. The median size of the AWE was 2.4 cm (range 1.0-5.3 cm). An acoustic power of 200-420 W was used, intermittent HIFU exposure of 1 s was applied. Treatment was considered complete when the entire nodule and its nearby 1 cm margin become hyperechoic on US. Pain relief after HIFU ablation was observed and the treated nodule received serial US examinations during follow-up. Results: All AWE was successfully ablated after one session of HIFU ablation, the ablation time lasted for 5-48 min (median 13 min), no major complications occurred. The cyclic pain disappeared in all patients during a mean follow-up of 18.7 months (range 3-31 months). The treated nodules gradually shank over time, 16 nodules became unnoticeable on US during follow-up. Conclusion: US-guided HIFU ablation appears to be safe and effective for the treatment of AWE.

  1. Integral test phantom for dosimetric quality assurance of image guided and intensity modulated stereotactic radiotherapy.

    Science.gov (United States)

    Létourneau, Daniel; Keller, Harald; Sharpe, Michael B; Jaffray, David A

    2007-05-01

    The objective of this work is to develop a dosimetric phantom quality assurance (QA) of linear accelerators capable of cone-beam CT (CBCT) image guided and intensity-modulated radiotherapy (IG-IMRT). This phantom is to be used in an integral test to quantify in real-time both the performance of the image guidance and the dose delivery systems in terms of dose localization. The prototype IG-IMRT QA phantom consisted of a cylindrical imaging phantom (CatPhan) combined with an array of 11 radiation diodes mounted on a 10 cm diameter disk, oriented perpendicular to the phantom axis. Basic diode response characterization was performed for 6 and 18 MV photons. The diode response was compared to planning system calculations in the open and penumbrae regions of simple and complex beam arrangements. The clinical use of the QA phantom was illustrated in an integral test of an IG-IMRT treatment designed for a clinical spinal radiosurgery case. The sensitivity of the phantom to multileaf collimator (MLC) calibration and setup errors in the clinical setting was assessed by introducing errors in the IMRT plan or by displacing the phantom. The diodes offered good response linearity and long-term reproducibility for both 6 and 18 MV. Axial dosimetry of coplanar beams (in a plane containing the beam axes) was made possible with the nearly isoplanatic response of the diodes over 360 degrees of gantry (usually within +/-1%). For single beam geometry, errors in phantom placement as small as 0.5 mm could be accurately detected (in gradient > or = 1% /mm). In clinical setting, MLC systematic errors of 1 mm on a single MLC bank introduced in the IMRT plan were easily detectable with the QA phantom. The QA phantom demonstrated also sufficient sensitivity for the detection of setup errors as small as 1 mm for the IMRT delivery. These results demonstrated that the prototype can accurately and efficiently verify the entire IG-IMRT process. This tool, in conjunction with image guidance

  2. Integral test phantom for dosimetric quality assurance of image guided and intensity modulated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Letourneau, Daniel; Keller, Harald; Sharpe, Michael B.; Jaffray, David A.

    2007-01-01

    The objective of this work is to develop a dosimetric phantom quality assurance (QA) of linear accelerators capable of cone-beam CT (CBCT) image guided and intensity-modulated radiotherapy (IG-IMRT). This phantom is to be used in an integral test to quantify in real-time both the performance of the image guidance and the dose delivery systems in terms of dose localization. The prototype IG-IMRT QA phantom consisted of a cylindrical imaging phantom (CatPhan) combined with an array of 11 radiation diodes mounted on a 10 cm diameter disk, oriented perpendicular to the phantom axis. Basic diode response characterization was performed for 6 and 18 MV photons. The diode response was compared to planning system calculations in the open and penumbrae regions of simple and complex beam arrangements. The clinical use of the QA phantom was illustrated in an integral test of an IG-IMRT treatment designed for a clinical spinal radiosurgery case. The sensitivity of the phantom to multileaf collimator (MLC) calibration and setup errors in the clinical setting was assessed by introducing errors in the IMRT plan or by displacing the phantom. The diodes offered good response linearity and long-term reproducibility for both 6 and 18 MV. Axial dosimetry of coplanar beams (in a plane containing the beam axes) was made possible with the nearly isoplanatic response of the diodes over 360 deg. of gantry (usually within ±1%). For single beam geometry, errors in phantom placement as small as 0.5 mm could be accurately detected (in gradient ≥1%/mm). In clinical setting, MLC systematic errors of 1 mm on a single MLC bank introduced in the IMRT plan were easily detectable with the QA phantom. The QA phantom demonstrated also sufficient sensitivity for the detection of setup errors as small as 1 mm for the IMRT delivery. These results demonstrated that the prototype can accurately and efficiently verify the entire IG-IMRT process. This tool, in conjunction with image guidance capabilities

  3. A review of transrectal ultrasound guided prostate biopsies: Is there ...

    African Journals Online (AJOL)

    Objective: We compared our institution's initial experience with transrectal ultrasound-guided (TRUS) prostate biopsies in a single arm prospective study to a historical cohort of finger guided (FG) biopsies. The primary outcome measure was prostate cancer detection. We documented our findings on TRUS including the ...

  4. A successful model to learn and implement ultrasound-guided venous catheterization in apheresis.

    Science.gov (United States)

    Gopalasingam, Nigopan; Thomsen, Anna-Marie Eller; Folkersen, Lars; Juhl-Olsen, Peter; Sloth, Erik

    2017-12-01

    Apheresis treatments can be performed with peripheral venous catheters (PVC), although central venous catheters (CVC) are inserted when PVCs fail or patient with history of difficult vascular access prior to the apheresis. Ultrasound guidance for PVC has shown promising results in other settings. To investigate if ultrasound guidance for PVC could be implemented among apheresis nurses. Second, how implementation of ultrasound guidance affected the number of CVCs used for apheresis per patient. Apheresis nurses completed a systematic training program for ultrasound-guided vascular access. All independent catheterizations were registered during the implementation stage. The number of CVCs in the pre- and postimplementation stages of the ultrasound guidance was compared. Six nurses completed the training program within a median of 48 days (range 38-83 days). In 77 patients, 485 independent ultrasound-guided PVC placements were performed during the implementation stage. All apheresis treatments (485/485) were accomplished using PVCs without requiring CVC as rescue. During the preimplementation stage, 125 of 273 (45.8%) procedures required a CVC for completion of apheresis procedures; during the postimplementation stage only 30 of 227 (13.2%) procedures required a CVC (p < 0.001). In the postimplementation stage, no CVCs were placed as rescue caused by failed PVCs but were only placed for patients where the ultrasound machine was unavailable. It indicates an effective success rate of 100% for ultrasound-guided PVC use. This study showed that ultrasound guidance could be implemented among apheresis nurses as a routine tool eliminating the need of CVC as a rescue. © 2017 Wiley Periodicals, Inc.

  5. Noninvasive treatment of deep venous thrombosis using pulsed ultrasound cavitation therapy (histotripsy) in a porcine model.

    Science.gov (United States)

    Maxwell, Adam D; Owens, Gabe; Gurm, Hitinder S; Ives, Kimberly; Myers, Daniel D; Xu, Zhen

    2011-03-01

    This study evaluated histotripsy as a noninvasive, image-guided method of thrombolysis in a porcine model of deep vein thrombosis. Histotripsy therapy uses short, high-intensity, focused ultrasound pulses to cause mechanical breakdown of targeted soft tissue by acoustic cavitation, which is guided by real-time ultrasound imaging. This is an in vivo feasibility study of histotripsy thrombolysis. Acute thrombi were formed in the femoral vein of juvenile pigs weighing 30-40 kg by balloon occlusion with two catheters and thrombin infusion. A 10-cm-diameter 1-MHz focused transducer was used for therapy. An 8-MHz ultrasound imager was used to align the clot with the therapy focus. Therapy consisted of five cycle pulses delivered at a rate of 1 kHz and peak negative pressure between 14 and 19 MPa. The focus was scanned along the long axis of the vessel to treat the entire visible clot during ultrasound exposure. The targeted region identified by a hyperechoic cavitation bubble cloud was visualized via ultrasound during treatment. Thrombus breakdown was apparent as a decrease in echogenicity within the vessel in 10 of 12 cases and in 7 cases improved flow through the vein as measured by color Doppler. Vessel histology found denudation of vascular endothelium and small pockets of hemorrhage in the vessel adventitia and underlying muscle and fatty tissue, but perforation of the vessel wall was never observed. The results indicate histotripsy has potential for development as a noninvasive treatment for deep vein thrombosis. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  6. Technical tips to perform safe and effective ultrasound guided steroid joint injections in children.

    Science.gov (United States)

    Parra, Dimitri A

    2015-01-01

    The aim of this article is to describe the technique used to perform ultrasound guided steroid joint injections in children in a group of joints that can be injected using ultrasound as the only image guidance modality. The technique is described and didactic figures are provided to illustrate key technical concepts. It is very important to be familiar with the sonographic appearance of the pediatric joints and the developing bone when performing ultrasound-guided joint injections in children.

  7. Ultrasound-Guided Regional Anesthesia Simulation Training: A Systematic Review.

    Science.gov (United States)

    Chen, Xiao Xu; Trivedi, Vatsal; AlSaflan, AbdulHadi A; Todd, Suzanne Clare; Tricco, Andrea C; McCartney, Colin J L; Boet, Sylvain

    Ultrasound-guided regional anesthesia (UGRA) has become the criterion standard of regional anesthesia practice. Ultrasound-guided regional anesthesia teaching programs often use simulation, and guidelines have been published to help guide URGA education. This systematic review aimed to examine the effectiveness of simulation-based education for the acquisition and maintenance of competence in UGRA. Studies identified in MEDLINE, EMBASE, CINAHL, Cochrane Central Register of Controlled Trials, and ERIC were included if they assessed simulation-based UGRA teaching with outcomes measured at Kirkpatrick level 2 (knowledge and skills), 3 (transfer of learning to the workplace), or 4 (patient outcomes). Two authors independently reviewed all identified references for eligibility, abstracted data, and appraised quality. After screening 176 citations and 45 full-text articles, 12 studies were included. Simulation-enhanced training improved knowledge acquisition (Kirkpatrick level 2) when compared with nonsimulation training. Seven studies measuring skill acquisition (Kirkpatrick level 2) found that simulation-enhanced UGRA training was significantly more effective than alternative teaching methods or no intervention. One study measuring transfer of learning into the clinical setting (Kirkpatrick level 3) found no difference between simulation-enhanced UGRA training and non-simulation-based training. However, this study was discontinued early because of technical challenges. Two studies examined patient outcomes (Kirkpatrick level 4), and one of these found that simulation-based UGRA training improved patient outcomes compared with didactic teaching. Ultrasound-guided regional anesthesia knowledge and skills significantly improved with simulation training. The acquired UGRA skills may be transferred to the clinical setting; however, further studies are required to confirm these changes translate to improved patient outcomes.

  8. Ultrasound-guided nerve block for inguinal hernia repair

    DEFF Research Database (Denmark)

    Bærentzen, Finn; Maschmann, Christian; Jensen, Kenneth

    2012-01-01

    Open inguinal hernia repair in adults is considered a minor surgical procedure but can be associated with significant pain. We aimed to evaluate acute postoperative pain management in male adults randomized to receive an ultrasound-guided ilioinguinal and iliohypogastric nerve block administered...

  9. SU-E-J-04: Integration of Interstitial High Intensity Therapeutic Ultrasound Applicators On a Clinical MRI-Guided High Intensity Focused Ultrasound Treatment Planning Software Platform

    Energy Technology Data Exchange (ETDEWEB)

    Ellens, N [Johns Hopkins University, Baltimore, Maryland (United States); Partanen, A [Philips Healthcare, Andover, Massachusetts (United States); Ghoshal, G; Burdette, E [Acoustic MedSystems Inc., Savoy, IL (United States); Farahani, K [National Cancer Institute, Bethesda, MD (United States)

    2015-06-15

    Purpose: Interstitial high intensity therapeutic ultrasound (HITU) applicators can be used to ablate tissue percutaneously, allowing for minimally-invasive treatment without ionizing radiation [1,2]. The purpose of this study was to evaluate the feasibility and usability of combining multielement interstitial HITU applicators with a clinical magnetic resonance imaging (MRI)-guided focused ultrasound software platform. Methods: The Sonalleve software platform (Philips Healthcare, Vantaa, Finland) combines anatomical MRI for target selection and multi-planar MRI thermometry to provide real-time temperature information. The MRI-compatible interstitial US applicators (Acoustic MedSystems, Savoy, IL, USA) had 1–4 cylindrical US elements, each 1 cm long with either 180° or 360° of active surface. Each applicator (4 Fr diameter, enclosed within a 13 Fr flexible catheter) was inserted into a tissue-mimicking agar-silica phantom. Degassed water was circulated around the transducers for cooling and coupling. Based on the location of the applicator, a virtual transducer overlay was added to the software to assist targeting and to allow automatic thermometry slice placement. The phantom was sonicated at 7 MHz for 5 minutes with 6–8 W of acoustic power for each element. MR thermometry data were collected during and after sonication. Results: Preliminary testing indicated that the applicator location could be identified in the planning images and the transducer locations predicted within 1 mm accuracy using the overlay. Ablation zones (thermal dose ≥ 240 CEM43) for 2 active, adjacent US elements ranged from 18 mm × 24 mm (width × length) to 25 mm × 25 mm for the 6 W and 8 W sonications, respectively. Conclusion: The combination of interstitial HITU applicators and this software platform holds promise for novel approaches in minimally-invasive MRI-guided therapy, especially when bony structures or air-filled cavities may preclude extracorporeal HIFU.[1] Diederich et al

  10. Ultrasound-guided needle aspiration of parotid abscess

    Directory of Open Access Journals (Sweden)

    André Takahashi

    2012-01-01

    Full Text Available Ultrasound (US has been used as a tool for parotid abscess diagnosis and treatment. The present article aimed to report a case of 72-year-old woman with parotid abscess treated by US-guided needle aspiration and conventional surgical drainage. Along with the clinical report, indications, advantages, and limitations of the method are discussed.

  11. A non-disruptive technology for robust 3D tool tracking for ultrasound-guided interventions.

    Science.gov (United States)

    Mung, Jay; Vignon, Francois; Jain, Ameet

    2011-01-01

    In the past decade ultrasound (US) has become the preferred modality for a number of interventional procedures, offering excellent soft tissue visualization. The main limitation however is limited visualization of surgical tools. A new method is proposed for robust 3D tracking and US image enhancement of surgical tools under US guidance. Small US sensors are mounted on existing surgical tools. As the imager emits acoustic energy, the electrical signal from the sensor is analyzed to reconstruct its 3D coordinates. These coordinates can then be used for 3D surgical navigation, similar to current day tracking systems. A system with real-time 3D tool tracking and image enhancement was implemented on a commercial ultrasound scanner and 3D probe. Extensive water tank experiments with a tracked 0.2mm sensor show robust performance in a wide range of imaging conditions and tool position/orientations. The 3D tracking accuracy was 0.36 +/- 0.16mm throughout the imaging volume of 55 degrees x 27 degrees x 150mm. Additionally, the tool was successfully tracked inside a beating heart phantom. This paper proposes an image enhancement and tool tracking technology with sub-mm accuracy for US-guided interventions. The technology is non-disruptive, both in terms of existing clinical workflow and commercial considerations, showing promise for large scale clinical impact.

  12. Ultrasound-guided radiofrequency neurotomy in cervical spine: sonoanatomic study of a new technique in cadavers

    International Nuclear Information System (INIS)

    Lee, S.-H.; Kang, C.H.; Lee, S.-H.; Derby, R.; Yang, S.N.; Lee, J.E.; Kim, J.H.; Kim, S.S.; Lee, J.-H.

    2008-01-01

    Aim: To develop an ultrasound-guided technique for radiofrequency (RF) cervical medial branch neurotomy and to validate the accuracy of this new method. Materials and methods: Five non-embalmed, fresh cadavers were used; three male and two female cadavers with a median age at death of 67.2 years (range 50-84 years). This study was conducted in two parts. First, two of the cadavers were used to define the sonographic target point for RF cervical medial branch neurotomy using high-resolution ultrasound (12 to 5 MHz). The needles were guided to five consecutive cervical medial branches in the cadavers under ultrasound guidance. Subsequently, the position of the ultrasound-guided needle was verified using C-arm fluoroscopy. Ultrasound-guided RF neurotomy was performed to the C5 medial branches in all five cadavers. In the three cadavers not used in the first part of the study, ultrasound-guided RF neurotomy without C-arm fluoroscopic confirmation was performed to the C3-C7 medial branches. The accuracy of neurotomy was assessed by pathological examination of the cervical medial branches obtained through cadaver dissection. Results: In all five cadavers, the sonographic target point was identified in all C3-C7 segments with the 12 to 5 MHz linear transducer. In all 20 needle placements for the first and second cadavers, C-arm fluoroscopy validated proper needle tip positions. In all five cadavers, successful neurotomy was pathologically confirmed in 30 of 34 cervical medial branches. Conclusions: Ultrasound-guided cervical medial branch neurotomy was successfully performed in 30 of 34 cervical medial branches in five cadavers. However, before eliminating fluoroscopic validation of final needle tip positioning, the technique should be validated in symptomatic patients

  13. Novel Use of the GuideLiner Catheter to Deliver Rotational Atherectomy Burrs in Tortuous Vessels

    Directory of Open Access Journals (Sweden)

    Minh Vo

    2014-01-01

    Full Text Available Rotational atherectomy (RA for heavily calcified lesions is essential for improved stent delivery and stent expansion. In tortuous vessels it is often difficult to advance the burr without rotation and possible injury to the endothelium of healthy vessel. The GuideLiner catheter, a child in mother catheter, has recently been used to allow for increased support for delivery of stents through tortuous vessels. We report a novel use of the GuideLiner for the delivery of an RA burr in tortuous vessels requiring increased guide support.

  14. Fluoroscopy- vs ultrasound-guided aspiration techniques in the management of periprosthetic joint infection: which is the best?

    Science.gov (United States)

    Randelli, Filippo; Brioschi, Marco; Randelli, Pietro; Ambrogi, Federico; Sdao, Silvana; Aliprandi, Alberto

    2018-01-01

    Fluid samples obtained from an affected joint still play a central role in the diagnosis of periprosthetic joint infection (PJI). It is the only preoperative test able to discover the causative microbiological agent. In the hip, fluid aspiration can be performed through fluoroscopy, ultrasound, or, less commonly, computed tomography. However, there is still a lack of consensus on which method is preferable in terms of efficacy and costbenefit. We, therefore, asked whether (1) the benefits in terms of sensitivity and specificity and (2) the costs were comparable between fluoroscopy- and ultrasound-guided joint aspirations in a suspicious of hip PJI. Between 2013 and 2016, 52 hip aspirations were performed on 49 patients with clinical, radiological, or serological suspicion of PJI, waiting for a revision surgery. The patients were divided in two groups: fluoroscopy- (n = 26) vs ultrasound-guided hip aspiration group (n = 26). These groups were also divided in control and infected patients. The criteria of MusculoSkeletal Infection Society (MSIS) were used, as gold standard, to define PJI. (1) Ultrasound-guided aspiration revealed valid sensitivity (89% vs 60%) and specificity (94% vs 81%) in comparison with fluoroscopic-guided aspiration. (2) The cost analysis was also in favor of ultrasound-guided aspiration (125.30€) than fluoroscopic-guided aspiration (343.58€). We concluded that ultrasound-guided hip aspiration could represent a valid, safe, and less expensive diagnostic alternative to fluoroscopic-guided aspiration in hip PJI.

  15. Simulation of ultrasound interaction with tissue

    International Nuclear Information System (INIS)

    Edee, M.K.A.; Ogulu, A.

    1995-08-01

    We model the effect of an ultrasound beam on a water phantom by considering water as an incompressible Newtonian viscous fluid. The two-dimensional flow velocities (u,v) induced in the water phantom, mimic displacement in living tissues for a phantom of unit width. The displacements depend on the ultrasound signal which is emitted and the model also predicts the nature of the signal received. 13 refs, 3 figs

  16. Ultrasound-guided interventional therapy for recurrent ovarian chocolate cysts.

    Science.gov (United States)

    Wang, Lu-Lu; Dong, Xiao-Qiu; Shao, Xiao-Hui; Wang, Si-Ming

    2011-10-01

    The aim of this study was to determine the effectiveness of ultrasound-guided interventional therapy in the treatment of postoperative recurrent chocolate cysts. The 198 patients enrolled in this study were divided into three groups. In group 1, the saline washing group, the cavity of the cyst was washed thoroughly with warm saline. In group 2, the ethanol short-time retention group, after washing with saline, the cyst was injected with 95% ethanol with a volume of half of the fluid aspirated from the cyst. Ten minutes later, the rest of the ethanol was aspirated. In group 3, the ethanol retention group, the procedures were the same as with the ethanol short-time retention group, except that 95% of the ethanol was retained in the cyst. An ultrasound examination was performed in the third, sixth and 12th months after therapy. The chocolate cyst cure rate was significantly higher in the ethanol retention group (96%, 66/69) than in the ethanol short-time retention group (82%, 56/68) and no case was cured in the first group (saline washing). We conclude that ultrasound-guided injection and 95% ethanol retention are an effective therapy for the treatment of postoperative recurrent chocolate cysts. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  17. Efficacy of ultrasound-guided thoracentesis catheter drainage for pleural effusion

    Science.gov (United States)

    Cao, Weitian; Wang, Yi; Zhou, Ningming; Xu, Bing

    2016-01-01

    The factors influencing the efficacy of ultrasound-guided thoracentesis catheter drainage were investigated in the present study. A retrospective analysis of clinical data from 435 patients who presented with a pleural effusion was performed. Patients were divided into a control group and an intervention group. Thirty-seven patients in the control group were given standard care using pleural puncture to draw the excess fluid. The 398 patients in the intervention group were treated using ultrasound-guided thoracentesis catheter drainage. The rate of successful drainage of a pleural effusion was significantly higher (Ppleural effusion. The efficacy of the procedure is related to the separation of pleural effusion, drainage tube type and tube diameter. PMID:28105155

  18. Success of ultrasound-guided versus landmark-guided arthrocentesis of hip, ankle, and wrist in a cadaver model.

    Science.gov (United States)

    Berona, Kristin; Abdi, Amin; Menchine, Michael; Mailhot, Tom; Kang, Tarina; Seif, Dina; Chilstrom, Mikaela

    2017-02-01

    The objectives of this study were to evaluate emergency medicine resident-performed ultrasound for diagnosis of effusions, compare the success of a landmark-guided (LM) approach with an ultrasound-guided (US) technique for hip, ankle and wrist arthrocentesis, and compare change in provider confidence with LM and US arthrocentesis. After a brief video on LM and US arthrocentesis, residents were asked to identify artificially created effusions in the hip, ankle and wrist in a cadaver model and to perform US and LM arthrocentesis of the effusions. Outcomes included success of joint aspiration, time to aspiration, and number of attempts. Residents were surveyed regarding their confidence in identifying effusions with ultrasound and performing LM and US arthrocentesis. Eighteen residents completed the study. Sensitivity of ultrasound for detecting joint effusion was 86% and specificity was 90%. Residents were successful with ultrasound in 96% of attempts and with landmark 89% of attempts (p=0.257). Median number of attempts was 1 with ultrasound and 2 with landmarks (p=0.12). Median time to success with ultrasound was 38s and 51s with landmarks (p=0.23). After the session, confidence in both US and LM arthrocentesis improved significantly, however the post intervention confidence in US arthrocentesis was higher than LM (4.3 vs. 3.8, p<0.001). EM residents were able to successfully identify joint effusions with ultrasound, however we were unable to detect significant differences in actual procedural success between the two modalities. Further studies are needed to define the role of ultrasound for arthrocentesis in the emergency department. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Outcome of ultrasound-guided small-bore catheter drainage in exudative pleural effusions.

    Science.gov (United States)

    Kiranantawat, Nantaka; Sungsiri, Jitpreedee; Geater, Sarayut L

    2014-05-01

    To evaluate the outcome and safety of ultrasound-guided percutaneous catheter drainage of exudative pleural effusion. The present study was a retrospective analysis of 412 pleural effusions from 373 patients that underwent ultrasound-guided small-bore catheter drainage in exudative pleural effusions between 2004 and 2009. The two most common causes for drainage were parapneumonic effusion or empyema (52.2%) and malignant effusion (30.3%), while the remains were trauma, iatrogenic, and others. Overall clinical success rate was 76.5%. The success rate was lower among malignant pleural effusion (p = 0.003). Causes of effusion were the only independent predictors related to success. Only five (1.2%) patients developed complication during the procedure. Seventy-five of 412 effusions (15.8%) developed complication during the period of drainage; the majority were drain blockage (9%) and accidental dislodgment (4.1%). Ultrasound-guided small-bore catheter drainage was a safe and efficient procedure for exudative pleural effusions.

  20. Ultrasound-guided hydrostatic reduction of intestinal intussusception: description of three cases

    Directory of Open Access Journals (Sweden)

    Martha Hanemann Kim

    2008-09-01

    Full Text Available With the objective of reporting the technique of ultrasound-guided hydrostatic reduction of intestinal intussusception, three cases with confirmed diagnosis of the disease submitted to reduction with this technique are described. All cases had successful reductions with no complications. One patient experienced a recurrence of the invagination eight days after treatment, which was surgically corrected. The technique of hydrostatic reversal of intestinal intussusception guided by ultrasound may be used in place of the conventional barium enema, since it is a minimally invasive and safe method, with high rates of success and few complications.

  1. High-Resolution Ultrasound-Switchable Fluorescence Imaging in Centimeter-Deep Tissue Phantoms with High Signal-To-Noise Ratio and High Sensitivity via Novel Contrast Agents.

    Science.gov (United States)

    Cheng, Bingbing; Bandi, Venugopal; Wei, Ming-Yuan; Pei, Yanbo; D'Souza, Francis; Nguyen, Kytai T; Hong, Yi; Yuan, Baohong

    2016-01-01

    For many years, investigators have sought after high-resolution fluorescence imaging in centimeter-deep tissue because many interesting in vivo phenomena-such as the presence of immune system cells, tumor angiogenesis, and metastasis-may be located deep in tissue. Previously, we developed a new imaging technique to achieve high spatial resolution in sub-centimeter deep tissue phantoms named continuous-wave ultrasound-switchable fluorescence (CW-USF). The principle is to use a focused ultrasound wave to externally and locally switch on and off the fluorophore emission from a small volume (close to ultrasound focal volume). By making improvements in three aspects of this technique: excellent near-infrared USF contrast agents, a sensitive frequency-domain USF imaging system, and an effective signal processing algorithm, for the first time this study has achieved high spatial resolution (~ 900 μm) in 3-centimeter-deep tissue phantoms with high signal-to-noise ratio (SNR) and high sensitivity (3.4 picomoles of fluorophore in a volume of 68 nanoliters can be detected). We have achieved these results in both tissue-mimic phantoms and porcine muscle tissues. We have also demonstrated multi-color USF to image and distinguish two fluorophores with different wavelengths, which might be very useful for simultaneously imaging of multiple targets and observing their interactions in the future. This work has opened the door for future studies of high-resolution centimeter-deep tissue fluorescence imaging.

  2. Ultrasound-guided injection of triamcinolone and bupivacaine in the management of De Quervain's disease.

    Science.gov (United States)

    Jeyapalan, Kanagaratnam; Choudhary, Surabhi

    2009-11-01

    The aim of this study was to describe the technique and usefulness of ultrasound-guided intrasynovial injection of triamcinolone and bupivacaine in treatment of de Quervain's disease. A total of 17 patients with symptomatic De Quervain's disease were included in this study. The procedure involved confirmation of diagnosis with ultrasound followed by guided injection of a mixture of 20 mg of triamcinolone (40 mg/ml) and 1 ml of 0.5% bupivacaine. Ultrasound guidance with a high resolution 15-Mhz footprint probe was used for injection into the first dorsal extensor compartment tendon sheath (E1). The response to ultrasound-guided injection was ascertained at the post procedure outpatient clinic appointment according to the follow-up clinic notes. There were 14 female and 3 male patients aged 29 to 74 years. Mean duration of symptoms was 8.9 months. One patient had an atypical septum in the first extensor compartment and the extensor pollicis brevis alone was involved. The mean post-injection follow-up was at 6.75 weeks. One patient was lost to follow-up. Fifteen out of 16 patients had significant symptomatic relief (93.75%). There were no immediate or delayed complications. Recurrence of symptoms was seen in 3 (20%) patients. Ultrasound-guided injection of triamcinolone and bupivacaine is safe and useful in controlling symptoms of De Quervain's disease. Correct needle placement with ultrasound guidance avoids intratendinous injection as well as local complications like fat atrophy and depigmentation.

  3. Magnetic Resonance-Guided High-Intensity-Focused Ultrasound for Palliation of Painful Skeletal Metastases: A Pilot Study.

    Science.gov (United States)

    Chan, Michael; Dennis, Kristopher; Huang, Yuexi; Mougenot, Charles; Chow, Edward; DeAngelis, Carlo; Coccagna, Jennifer; Sahgal, Arjun; Hynynen, Kullervo; Czarnota, Gregory; Chu, William

    2017-10-01

    Bone is one of the most common sites of metastases, with bone metastases-related pain representing a significant source of morbidity among patients with cancer. Magnetic resonance-guided focused ultrasound is a noninvasive, outpatient modality with the potential for treating painful bone metastases. The aim of this study is to report our initial experience with magnetic resonance-guided focused ultrasound in the treatment of bone metastases and our preliminary analysis of urinary cytokine levels after therapy. This was a single-center pilot study of 10 patients with metastatic cancer to investigate the feasibility of magnetic resonance-guided focused ultrasound for primary pain control in device-accessible skeletal metastases. Treatments were performed on a clinical magnetic resonance-guided focused ultrasound system using a volumetric ablation technique. Primary efficacy was assessed using Brief Pain Inventory scores and morphine equivalent daily dose intake at 3 time points: before, day 14, and day 30 after the magnetic resonance-guided focused ultrasound treatment. Urine cytokines were measured 3 days before treatment and 2 days after the treatment. Of the 10 patients, 8 were followed up 14 days and 6 were followed up 30 days after the treatment. At day 14, 3 patients (37.5%) exhibited partial pain response and 4 patients (50%) exhibited an indeterminate response, and at day 30 after the treatment, 5 patients (83%) exhibited partial pain response. No treatment-related adverse events were recorded. Of the urine cytokines measured, only Transforming growth factor alpha (TGFα) demonstrated an overall decrease, with a trend toward statistical significance ( P = .078). Our study corroborates magnetic resonance-guided focused ultrasound as a feasible and safe modality as a primary, palliative treatment for painful bone metastases and contributes to the limited body of literature using magnetic resonance-guided focused ultrasound for this clinical indication.

  4. A CT-ultrasound-coregistered augmented reality enhanced image-guided surgery system and its preliminary study on brain-shift estimation

    International Nuclear Information System (INIS)

    Huang, C H; Hsieh, C H; Lee, J D; Huang, W C; Lee, S T; Wu, C T; Sun, Y N; Wu, Y T

    2012-01-01

    With the combined view on the physical space and the medical imaging data, augmented reality (AR) visualization can provide perceptive advantages during image-guided surgery (IGS). However, the imaging data are usually captured before surgery and might be different from the up-to-date one due to natural shift of soft tissues. This study presents an AR-enhanced IGS system which is capable to correct the movement of soft tissues from the pre-operative CT images by using intra-operative ultrasound images. First, with reconstructing 2-D free-hand ultrasound images to 3-D volume data, the system applies a Mutual-Information based registration algorithm to estimate the deformation between pre-operative and intra-operative ultrasound images. The estimated deformation transform describes the movement of soft tissues and is then applied to the pre-operative CT images which provide high-resolution anatomical information. As a result, the system thus displays the fusion of the corrected CT images or the real-time 2-D ultrasound images with the patient in the physical space through a head mounted display device, providing an immersive augmented-reality environment. For the performance validation of the proposed system, a brain phantom was utilized to simulate brain-shift scenario. Experimental results reveal that when the shift of an artificial tumor is from 5mm ∼ 12mm, the correction rates can be improved from 32% ∼ 45% to 87% ∼ 95% by using the proposed system.

  5. Ultrasound-guided wire localization of lesions detected on ...

    African Journals Online (AJOL)

    Background: Wire localization for planned surgical treatment in the management of breast cancer is underutilized in our environment. The objective of this study is to assess the role of ultrasound-guided wire localization of breast masses detected on screening mammography and its impact on biopsy and breast ...

  6. Ultrasound-guided endoscopic transgastric drainage of a post ...

    African Journals Online (AJOL)

    Despite of a number of techniques in the armentarium of the paediatric surgeon, the management of pancreatic pseudocysts remains a challenge. We report on a case of a 5-year-old child with a post-traumatic pancreatic pseudocyst who was successfully treated with endoscopic ultrasound-guided transgastric approach.

  7. Doppler ultrasound compatible plastic material for use in rigid flow models.

    Science.gov (United States)

    Wong, Emily Y; Thorne, Meghan L; Nikolov, Hristo N; Poepping, Tamie L; Holdsworth, David W

    2008-11-01

    A technique for the rapid but accurate fabrication of multiple flow phantoms with variations in vascular geometry would be desirable in the investigation of carotid atherosclerosis. This study demonstrates the feasibility and efficacy of implementing numerically controlled direct-machining of vascular geometries into Doppler ultrasound (DUS)-compatible plastic for the easy fabrication of DUS flow phantoms. Candidate plastics were tested for longitudinal speed of sound (SoS) and acoustic attenuation at the diagnostic frequency of 5 MHz. Teflon was found to have the most appropriate SoS (1376 +/- 40 m s(-1) compared with 1540 m s(-1) in soft tissue) and thus was selected to construct a carotid bifurcation flow model with moderate eccentric stenosis. The vessel geometry was machined directly into Teflon using a numerically controlled milling technique. Geometric accuracy of the phantom lumen was verified using nondestructive micro-computed tomography. Although Teflon displayed a higher attenuation coefficient than other tested materials, Doppler data acquired in the Teflon flow model indicated that sufficient signal power was delivered throughout the depth of the vessel and provided comparable velocity profiles to that obtained in the tissue-mimicking phantom. Our results indicate that Teflon provides the best combination of machinability and DUS compatibility, making it an appropriate choice for the fabrication of rigid DUS flow models using a direct-machining method.

  8. Reflection-artifact-free photoacoustic imaging using PAFUSion (photoacoustic-guided focused ultrasound)

    Science.gov (United States)

    Kuniyil Ajith Singh, Mithun; Jaeger, Michael; Frenz, Martin; Steenbergen, Wiendelt

    2016-03-01

    Reflection artifacts caused by acoustic inhomogeneities are a main challenge to deep-tissue photoacoustic imaging. Photoacoustic transients generated by the skin surface and superficial vasculature will propagate into the tissue and reflect back from echogenic structures to generate reflection artifacts. These artifacts can cause problems in image interpretation and limit imaging depth. In its basic version, PAFUSion mimics the inward travelling wave-field from blood vessel-like PA sources by applying focused ultrasound pulses, and thus provides a way to identify reflection artifacts. In this work, we demonstrate reflection artifact correction in addition to identification, towards obtaining an artifact-free photoacoustic image. In view of clinical applications, we implemented an improved version of PAFUSion in which photoacoustic data is backpropagated to imitate the inward travelling wave-field and thus the reflection artifacts of a more arbitrary distribution of PA sources that also includes the skin melanin layer. The backpropagation is performed in a synthetic way based on the pulse-echo acquisitions after transmission on each single element of the transducer array. We present a phantom experiment and initial in vivo measurements on human volunteers where we demonstrate significant reflection artifact reduction using our technique. The results provide a direct confirmation that reflection artifacts are prominent in clinical epi-photoacoustic imaging, and that PAFUSion can reduce these artifacts significantly to improve the deep-tissue photoacoustic imaging.

  9. An ultrasound-driven needle-insertion robot for percutaneous cholecystostomy

    International Nuclear Information System (INIS)

    Hong, J; Dohi, T; Hashizume, M; Konishi, K; Hata, N

    2004-01-01

    A real-time ultrasound-guided needle-insertion medical robot for percutaneous cholecystostomy has been developed. Image-guided interventions have become widely accepted because they are consistent with minimal invasiveness. However, organ or abnormality displacement due to involuntary patient motion may undesirably affect the intervention. The proposed instrument uses intraoperative images and modifies the needle path in real time by using a novel ultrasonic image segmentation technique. In phantom and volunteer experiments, the needle path updating time was 130 and 301 ms per cycle, respectively. In animal experiments, the needle could be placed accurately in the target

  10. Amoebic liver abscess: Drained by ultrasound guided percutaneous ...

    African Journals Online (AJOL)

    Summary: Amoebic Liver Abscess in a 20-month-old child: A case of amoebic liver abscess in a Nigerian child is presented. Management consisted of 10days course of Metronidazole and 5days course of Tinidazole without improvement. This was followed by four sessions of ultrasound guided percutaneous needle ...

  11. Ultrasound-guided botulinum toxin injections

    Directory of Open Access Journals (Sweden)

    S. E. Khatkova

    2016-01-01

    Full Text Available One of the key conditions for achieving the desirable result during botulinum toxin therapy for muscular dystonia, spasticity, and other diseases accompanied by spasm, pain, and autonomic dysfunction (dystonias, spasticity, etc. is the proper administration of the agent into the muscles directly involved in the pathological process. The exact entry of botulinum toxin into the target muscles is essential for successful and safe treatment because its injection into a normal muscle may cause side effects. The most common errors are the incorrect depth and incorrect direction of a needle on insertion. Therefore, the exact injection of the agent particularly into the shallow and deep muscles is a difficult task even for an experienced specialist and requires the use of controlling methods.The European Consensus on Botulinum Toxin Therapy points out that various injection techniques are needed for the better identification of necessary muscles. However, there are currently no reports on the clear advantage of any technique. In our country, injections using palpation and anatomical landmarks have been widely used in routine practice so far; electromyographic monitoring and electrostimulation have been less frequently applied. In recent years, the new method ultrasound-guided injection has continued to grow more popular. This effective, accessible, and easy-to-use method makes it possible to manage a real-time injection process and to ensure the exact entry of the agent into the muscle. This paper is dedicated to a comparative analysis of different injection methods and to a description of the ultrasound-guided technique and its advantages over others. 

  12. Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy

    Science.gov (United States)

    Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk

    2017-03-01

    A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.

  13. Ultrasound guided electrical impedance tomography for 2D free-interface reconstruction

    Science.gov (United States)

    Liang, Guanghui; Ren, Shangjie; Dong, Feng

    2017-07-01

    The free-interface detection problem is normally seen in industrial or biological processes. Electrical impedance tomography (EIT) is a non-invasive technique with advantages of high-speed and low cost, and is a promising solution for free-interface detection problems. However, due to the ill-posed and nonlinear characteristics, the spatial resolution of EIT is low. To deal with the issue, an ultrasound guided EIT is proposed to directly reconstruct the geometric configuration of the target free-interface. In the method, the position of the central point of the target interface is measured by a pair of ultrasound transducers mounted at the opposite side of the objective domain, and then the position measurement is used as the prior information for guiding the EIT-based free-interface reconstruction. During the process, a constrained least squares framework is used to fuse the information from different measurement modalities, and the Lagrange multiplier-based Levenberg-Marquardt method is adopted to provide the iterative solution of the constraint optimization problem. The numerical results show that the proposed ultrasound guided EIT method for the free-interface reconstruction is more accurate than the single modality method, especially when the number of valid electrodes is limited.

  14. Ultrasound guided electrical impedance tomography for 2D free-interface reconstruction

    International Nuclear Information System (INIS)

    Liang, Guanghui; Ren, Shangjie; Dong, Feng

    2017-01-01

    The free-interface detection problem is normally seen in industrial or biological processes. Electrical impedance tomography (EIT) is a non-invasive technique with advantages of high-speed and low cost, and is a promising solution for free-interface detection problems. However, due to the ill-posed and nonlinear characteristics, the spatial resolution of EIT is low. To deal with the issue, an ultrasound guided EIT is proposed to directly reconstruct the geometric configuration of the target free-interface. In the method, the position of the central point of the target interface is measured by a pair of ultrasound transducers mounted at the opposite side of the objective domain, and then the position measurement is used as the prior information for guiding the EIT-based free-interface reconstruction. During the process, a constrained least squares framework is used to fuse the information from different measurement modalities, and the Lagrange multiplier-based Levenberg–Marquardt method is adopted to provide the iterative solution of the constraint optimization problem. The numerical results show that the proposed ultrasound guided EIT method for the free-interface reconstruction is more accurate than the single modality method, especially when the number of valid electrodes is limited. (paper)

  15. Preliminary study of ergonomic behavior during simulated ultrasound-guided regional anesthesia using a head-mounted display.

    Science.gov (United States)

    Udani, Ankeet D; Harrison, T Kyle; Howard, Steven K; Kim, T Edward; Brock-Utne, John G; Gaba, David M; Mariano, Edward R

    2012-08-01

    A head-mounted display provides continuous real-time imaging within the practitioner's visual field. We evaluated the feasibility of using head-mounted display technology to improve ergonomics in ultrasound-guided regional anesthesia in a simulated environment. Two anesthesiologists performed an equal number of ultrasound-guided popliteal-sciatic nerve blocks using the head-mounted display on a porcine hindquarter, and an independent observer assessed each practitioner's ergonomics (eg, head turning, arching, eye movements, and needle manipulation) and the overall block quality based on the injectate spread around the target nerve for each procedure. Both practitioners performed their procedures without directly viewing the ultrasound monitor, and neither practitioner showed poor ergonomic behavior. Head-mounted display technology may offer potential advantages during ultrasound-guided regional anesthesia.

  16. Ultrasound-guided thoracenthesis: the V-point as a site for optimal drainage positioning.

    Science.gov (United States)

    Zanforlin, A; Gavelli, G; Oboldi, D; Galletti, S

    2013-01-01

    In the latest years the use of lung ultrasound is increasing in the evaluation of pleural effusions, because it makes follow-up easier and drainage more efficient by providing guidance on the most appropriate sampling site. However, no standardized approach for ultrasound-guided thoracenthesis is actually available. To evaluate our usual ultrasonographic landmark as a possible standard site to perform thoracenthesis by assessing its value in terms of safety and efficiency (success at first attempt, drainage as complete as possible). Hospitalized patients with non organized pleural effusion underwent thoracenthesis after ultrasound evaluation. The point showing on ultrasound the maximum thickness of the effusion ("V-point") was chosen for drainage. 45 ultrasound guided thoracenthesis were performed in 12 months. In 22 cases there were no complications; 16 cases of cough, 2 cases of mild dyspnea without desaturation, 4 cases of mild pain; 2 cases of complications requiring medical intervention occurred. No case of pneumothorax related to the procedure was detected. In all cases drainage was successful on the first attempt. The collected values of maximum thickness at V-point (min 3.4 cm - max 15.3 cm) and drained fluid volume (min 70 ml - max 2000 ml) showed a significative correlation (p measure of the maximum thickness at V-point provides high efficiency to ultrasound guided thoracentesis and allows to estimate the amount of fluid in the pleural cavity. It is also an easy parameter that makes the proposed method quick to learn and apply.  

  17. MR-Guided Focused Ultrasound for the Treatment of Uterine Fibroids

    International Nuclear Information System (INIS)

    Hesley, Gina K.; Gorny, Krzysztof R.; Woodrum, David A.

    2013-01-01

    Magnetic resonance imaging–guided focused ultrasound (MRgFUS) ablation of uterine fibroids provides a minimally invasive outpatient technique for targeting and treating symptomatic uterine fibroids. Magnetic resonance imaging provides a guidance platform that has high temporal and spatial resolution for guiding, as well as thermal monitoring of the procedure. The high-intensity focused ultrasound provides a mechanism for delivering large amounts of energy directly into the fibroid without causing detrimental effects to the nontarget tissues. Early and intermediate follow-up of patients treated with MRgFUS provided promising results on the efficacy of the technique for providing symptom relief to patients. As more long-term follow-up data are published, the efficacy of this technique can be compared to more invasive surgical and minimally invasive catheter treatments.

  18. Ultrasound-Guided Versus Landmark-Guided Local Corticosteroid Injection for Carpal Tunnel Syndrome: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.

    Science.gov (United States)

    Babaei-Ghazani, Arash; Roomizadeh, Peyman; Forogh, Bijan; Moeini-Taba, Seyed-Mohammad; Abedini, Amin; Kadkhodaie, Mona; Jahanjoo, Fateme; Eftekharsadat, Bina

    2018-04-01

    To review the literature and assess the comparative effectiveness of ultrasound-guided versus landmark-guided local corticosteroid injections in patients with carpal tunnel syndrome (CTS). Cochrane Central Register of Controlled Trials, MEDLINE (PubMed), Embase (Ovid), and Web of Science (from inception to February 1, 2017). Randomized controlled trials (RCTs) comparing ultrasound-guided injection with landmark-guided injection in patients with CTS were included. Two authors independently screened abstracts and full texts. The outcomes of interest were Symptom Severity Scale (SSS) and Functional Status Scale (FSS) scores of the Boston Carpal Tunnel Questionnaire and 4 electrodiagnostic parameters, including compound muscle action potential (CMAP), sensory nerve action potential (SNAP), distal motor latency (DML), and distal sensory latency (DSL). Overall, 569 abstracts were retrieved and checked for eligibility; finally, 3 RCTs were included (181 injected hands). Pooled analysis showed that ultrasound-guided injection was more effective in SSS improvement (mean difference [MD], -.46; 95% confidence interval [CI], -.59 to -.32; P.99), DML (MD, .05; 95% CI, -.30 to .39; P=.80), or DSL (MD, .00; 95% CI, -.65 to .65; P>.99). This review suggested that ultrasound-guided injection was more effective than landmark-guided injection in symptom severity improvement in patients with CTS; however, no significant differences were observed in functional status or electrodiagnostic improvements between the 2 methods. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  19. Practice guidelines for endoscopic ultrasound-guided celiac plexus neurolysis

    DEFF Research Database (Denmark)

    Wyse, Jonathan M; Battat, Robert; Sun, Siyu

    2017-01-01

    OBJECTIVES: The objective of guideline was to provide clear and relevant consensus statements to form a practical guideline for clinicians on the indications, optimal technique, safety and efficacy of endoscopic ultrasound guided celiac plexus neurolysis (EUS-CPN). METHODS: Six important clinical...

  20. Practice guidelines for endoscopic ultrasound-guided celiac plexus neurolysis

    NARCIS (Netherlands)

    Wyse, J.M. (Jonathan M.); Battat, R. (Robert); Sun, S. (Siyu); A. Saftoiu (Adrian); Siddiqui, A.A. (Ali A.); Leong, A.T. (Ang Tiing); Arias, B.L.A. (Brenda Lucia Arturo); Fabbri, C. (Carlo); Adler, D.G. (Douglas G.); Santo, E. (Erwin); Kalaitzakis, E. (Evangelos); Artifon, E. (Everson); Mishra, G. (Girish); Okasha, H.H. (Hussein Hassan); J.-W. Poley (Jan-Werner); Guo, J. (Jintao); Vila, J.J. (Juan J.); Lee, L.S. (Linda S.); Sharma, M. (Malay); Bhutani, M.S. (Manoop S.); M. Giovannini (Marcello); Kitano, M. (Masayuki); Eloubeidi, M.A. (Mohamad Ali); Khashab, M.A. (Mouen A.); Nguyen, N.Q. (Nam Q.); Saxena, P. (Payal); Vilmann, P. (Peter); Fusaroli, P. (Pietro); Garg, P.K. (Pramod Kumar); Ho, S. (Sammy); Mukai, S. (Shuntaro); Carrara, S. (Silvia); Sridhar, S. (Subbaramiah); S. Lakhtakia (S.); Rana, S.S. (Surinder S.); Dhir, V. (Vinay); Sahai, A.V. (Anand V.)

    2017-01-01

    textabstractObjectives: The objective of guideline was to provide clear and relevant consensus statements to form a practical guideline for clinicians on the indications, optimal technique, safety and efficacy of endoscopic ultrasound guided celiac plexus neurolysis (EUS-CPN). Methods: Six important

  1. Rapid prototyping of biomimetic vascular phantoms for hyperspectral reflectance imaging

    Science.gov (United States)

    Ghassemi, Pejhman; Wang, Jianting; Melchiorri, Anthony J.; Ramella-Roman, Jessica C.; Mathews, Scott A.; Coburn, James C.; Sorg, Brian S.; Chen, Yu; Joshua Pfefer, T.

    2015-12-01

    The emerging technique of rapid prototyping with three-dimensional (3-D) printers provides a simple yet revolutionary method for fabricating objects with arbitrary geometry. The use of 3-D printing for generating morphologically biomimetic tissue phantoms based on medical images represents a potentially major advance over existing phantom approaches. Toward the goal of image-defined phantoms, we converted a segmented fundus image of the human retina into a matrix format and edited it to achieve a geometry suitable for printing. Phantoms with vessel-simulating channels were then printed using a photoreactive resin providing biologically relevant turbidity, as determined by spectrophotometry. The morphology of printed vessels was validated by x-ray microcomputed tomography. Channels were filled with hemoglobin (Hb) solutions undergoing desaturation, and phantoms were imaged with a near-infrared hyperspectral reflectance imaging system. Additionally, a phantom was printed incorporating two disjoint vascular networks at different depths, each filled with Hb solutions at different saturation levels. Light propagation effects noted during these measurements-including the influence of vessel density and depth on Hb concentration and saturation estimates, and the effect of wavelength on vessel visualization depth-were evaluated. Overall, our findings indicated that 3-D-printed biomimetic phantoms hold significant potential as realistic and practical tools for elucidating light-tissue interactions and characterizing biophotonic system performance.

  2. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology

    DEFF Research Database (Denmark)

    Dumonceau, J-M; Polkowski, M; Larghi, A

    2011-01-01

    This article is part of a combined publication that expresses the current view of the European Society of Gastrointestinal Endoscopy (ESGE) about endoscopic ultrasound (EUS)-guided sampling in gastroenterology, including EUS-guided fine needle aspiration (EUS-FNA) and EUS-guided trucut biopsy (EU...

  3. Quality control culture of diagnostic ultrasound parameters

    International Nuclear Information System (INIS)

    Andam, A.A.B; Addison, E.C.K.; Aggry-Smith, S.; Nani, E.K.

    2003-01-01

    A phantom, consisting of two phases, has been designed and constructed to mimic the human body. The phase one phantom was designed to mimic a a surface lesion in the human body and the phase two phantom designed to mimic a section of the whole body. Ultrasound scans of the phantom were acquired for various material in the phantom at six hospitals in Kumasi, Ghana. A linear array transducer with parallel beams having a convex probe and a 3.5 MHz ultrasound frequency were used to carry out the experiment. It was observed that the depth of penetration of ultrasound, which constitutes the maximum depth of visualization or sensitivity, is determined by the frequency of the transducer, the attenuation of the medium being imaged and the system settings. Uniformity and linearity of the machines investigated were found to be within clinically acceptable standards. Spatial resolution, comprising axial and lateral resolutions, was observed to be satisfactory for the machines tested. It was observed that lateral resolution improved with the narrowing of the beam width. The ultrasound scanners at the selected hospitals were found to be operating at the expected level of performance. This work highlights the importance of putting in place a locally based mechanism for quality control of diagnostic ultrasound machines (author)

  4. Effects of arthroscopy-guided suprascapular nerve block combined with ultrasound-guided interscalene brachial plexus block for arthroscopic rotator cuff repair: a randomized controlled trial.

    Science.gov (United States)

    Lee, Jae Jun; Hwang, Jung-Taek; Kim, Do-Young; Lee, Sang-Soo; Hwang, Sung Mi; Lee, Na Rea; Kwak, Byung-Chan

    2017-07-01

    The aim of this study was to compare the pain relieving effect of ultrasound-guided interscalene brachial plexus block (ISB) combined with arthroscopy-guided suprascapular nerve block (SSNB) with that of ultrasound-guided ISB alone within the first 48 h after arthroscopic rotator cuff repair. Forty-eight patients with rotator cuff tears who had undergone arthroscopic rotator cuff repair were enrolled. The 24 patients in group 1 received ultrasound-guided ISB and arthroscopy-guided SSNB; the remaining 24 patients in group 2 underwent ultrasound-guided ISB alone. Visual analogue scale pain score and patient satisfaction score were checked at 1, 3, 6, 12, 18, 24, and 48 h post-operatively. Group 1 had a lower visual analogue scale pain score at 3, 6, 12, 18, 24, and 48 h post-operatively (1.7  6.0, 6.2 > 4.3, 6.4 > 5.1, 6.9 > 5.9, 7.9 > 7.1). Six patients in group 1 developed rebound pain twice, and the others in group 1 developed it once. All of the patients in group 2 had one rebound phenomenon each (p = 0.010). The mean timing of rebound pain in group 1 was later than that in group 2 (15.5 > 9.3 h, p  4.0, p = 0.001). Arthroscopy-guided SSNB combined with ultrasound-guided ISB resulted in lower visual analogue scale pain scores at 3-24 and 48 h post-operatively, and higher patient satisfaction scores at 6-36 h post-operatively with the attenuated rebound pain compared to scores in patients who received ultrasound-guided ISB alone after arthroscopic rotator cuff repair. The combined blocks may relieve post-operative pain more effectively than the single block within 48 h after arthroscopic cuff repair. Randomized controlled trial, Level I. ClinicalTrials.gov Identifier: NCT02424630.

  5. Ultrasound-guided pigtail catheters for drainage of various pleural diseases.

    Science.gov (United States)

    Liu, Yi-Heng; Lin, Yu-Chao; Liang, Shinn-Jye; Tu, Chih-Yen; Chen, Chia-Hung; Chen, Hung-Jen; Chen, Wei; Shih, Chuen-Ming; Hsu, Wu-Huei

    2010-10-01

    Little is known about the efficacy and safety of ultrasound-guided pigtail catheters for the management of various pleural diseases in the emergency department, ward, and intensive care unit. We conducted a retrospective study in a university hospital during a 1-year interval. A total of 276 patients (178 men and 98 women) underwent 332 pigtail catheters (the drain size ranged from 10F to 16F) under ultrasound guidance. The mean ± SEM patient age was 59 ± 18 years, and mean duration of drainage was 6.1 ± 2 days. A total of 64 drains (19.2%) were inserted for pneumothoraces; 98 drains (29.5%), for malignant effusions; 119 drains (35.8%), for parapneumonic effusions/empyemas; and 38 drains (11.4%), for massive transudate pleural effusions. The overall success rate was 72.9%. The success rate was highest when the drain was used to treat massive transudate effusions (81.6%) and malignant pleural effusions (75.5%), followed by parapneumonic effusions/empyemas (72.2%), hemothoraces (66.6%), and pneumothoraces (64.0%). Only 10 (3.0%) drains had complications due to the procedure, including infection (n = 4, 1.2%), dislodgment (n = 4, 1.2%), wound bleeding at the pigtail catheter puncture area complicated with hemothoraces (n = 1, 0.3%), and lung puncture (n = 1, 0.3%). There was no significant difference in success rate when different catheter sizes were used to treat pleural diseases. Ultrasound-guided pigtail catheters provide a safe and effective method of draining various pleural diseases. We strongly suggest that ultrasound-guided pigtail catheters be considered as the initial draining method for a variety of pleural diseases. Copyright © 2010 Elsevier Inc. All rights reserved.

  6. Predicting target vessel location on robot-assisted coronary artery bypass graft using CT to ultrasound registration

    International Nuclear Information System (INIS)

    Cho, Daniel S.; Linte, Cristian; Chen, Elvis C. S.; Bainbridge, Daniel; Wedlake, Chris; Moore, John; Barron, John; Patel, Rajni; Peters, Terry

    2012-01-01

    Purpose: Although robot-assisted coronary artery bypass grafting (RA-CABG) has gained more acceptance worldwide, its success still depends on the surgeon's experience and expertise, and the conversion rate to full sternotomy is in the order of 15%-25%. One of the reasons for conversion is poor pre-operative planning, which is based solely on pre-operative computed tomography (CT) images. In this paper, the authors propose a technique to estimate the global peri-operative displacement of the heart and to predict the intra-operative target vessel location, validated via both an in vitro and a clinical study. Methods: As the peri-operative heart migration during RA-CABG has never been reported in the literatures, a simple in vitro validation study was conducted using a heart phantom. To mimic the clinical workflow, a pre-operative CT as well as peri-operative ultrasound images at three different stages in the procedure (Stage 0 --following intubation; Stage 1 --following lung deflation; and Stage 2 --following thoracic insufflation) were acquired during the experiment. Following image acquisition, a rigid-body registration using iterative closest point algorithm with the robust estimator was employed to map the pre-operative stage to each of the peri-operative ones, to estimate the heart migration and predict the peri-operative target vessel location. Moreover, a clinical validation of this technique was conducted using offline patient data, where a Monte Carlo simulation was used to overcome the limitations arising due to the invisibility of the target vessel in the peri-operative ultrasound images. Results: For the in vitro study, the computed target registration error (TRE) at Stage 0 , Stage 1 , and Stage 2 was 2.1, 3.3, and 2.6 mm, respectively. According to the offline clinical validation study, the maximum TRE at the left anterior descending (LAD) coronary artery was 4.1 mm at Stage 0 , 5.1 mm at Stage 1 , and 3.4 mm at Stage 2 . Conclusions: The authors

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart ... Articles and Media Angioplasty and Vascular Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview ...

  8. Percutaneous antegrade pyelgraphy guided by ultrasound

    International Nuclear Information System (INIS)

    Kim, Jin Gyoo; Chung, Chun Phil; Lee, Suk Hong; Sol, Chang Hyo; Kim, Byung Soo

    1985-01-01

    The authors performed percutaneous antegrade pyelography guided by ultrasound on 33 patients, from June 1982 to October 1984, at the Department of Radiology, Busan National University Hospital. The results obtained were as follows: 1. Of the 31 cases, 17 cases (51.5%) were female and 16 cases (48.5%) were male, and age distribution was nearly even, but most prevalent age group was third decade. 2. Comparing intravenous pyelographic findings with ultrasonographic findings, pyelographically nonvisualized kidney 15 cases (45.5%) were hydronephrosis 12 cases, multiple cysts 2 cases, and intrarenal cystic mass 1 case, ultrasonographically. Pyelographically hydronephrosis 9 cases (27.3%) were all hydronephrosis, ultrasonographically. Intrarenal mass 5 cases (15.2%) were all intrarenal cystic mass, NVK with air kidney 1 case (3.0%) was air in perirenal space, partial NVK 1 case (3.0%) was perirenal fluid, suprarenal mass 1 case (3.0%) was suprarenal intrarenal and huge perirenal cystic masses, ultrasonographically. 3. On technical reliability of antegrade pyelography under ultrasound guide, 31 cases (93.9%) could be done fluid aspiration and visualization, and 2 cases (6.1%) could be only done fluid aspiration but failed visualization. 31 successful cases were visualization of collecting systems 23 cases, visualization of cyst 6 case, and visualization of perirenal space 2 cases. 2 partical successful cases were perirenal injection 1 case and parenchymal injection 1 case. 4. On fluid aspiration, 22 cases (66.7%) were clear, but 11 cases (33.3%) were not clear, which were pus 7 cases, turbid urine 2 cases, bloody urine 1 case, and bloody pus and air 1 case. 5. Comparing ultrasonographic findings with antegrade pyelographic findings, ultrasonographiclly hydronephrosis 21 cases revealed obstruction in 16 cases, antegrade pyelographicaaly, which were consisted of ureteral stricture 14 case, ureteral stone 1 case, and ureteral mass 1 case, non-obstruction in 4 cases, which

  9. Ultrasound-Guided 50% Ethyl Alcohol Injection for Patients With Malleolar and Olecranon Bursitis: A Prospective Pilot Study

    Science.gov (United States)

    Hong, Ji Seong; Lee, Jin Hyung

    2016-01-01

    Objective To evaluate the feasibility and effect of ultrasound-guided ethyl alcohol injection on malleolar and olecranon synovial proliferative bursitis. Methods Twenty-four patients received ultrasound-guided 50% diluted ethyl alcohol injection at the site of synovial proliferative bursitis after aspiration of the free fluid. Results Swelling and symptoms significantly decreased in 13 of the 24 patients without any complications. Eleven patients had partial improvement in swelling and symptoms. Conclusion Ultrasound-guided alcohol injection could be an alternative therapeutic option before surgery in patients with chronic intractable malleolar and olecranon synovial proliferative bursitis. PMID:27152282

  10. Ultrasound-guided procedures around the wrist and hand: How to do

    International Nuclear Information System (INIS)

    Orlandi, Davide; Corazza, Angelo; Silvestri, Enzo; Serafini, Giovanni; Savarino, Edoardo Vincenzo; Garlaschi, Giacomo; Mauri, Giovanni; Cimmino, Marco Amedeo; Sconfienza, Luca Maria

    2014-01-01

    Ultrasound has emerged as a low-cost, radiation-free and effective imaging technique to detect joint abnormalities and to guide percutaneous procedures. Being superficial, wrist and hand tendons and joints represent a good target to perform such procedures using ultrasound guidance. This kind of approach allows for a clear and real-time visualization of the needles during their whole path. In this setting, the knowledge of technical aspects and tips is essential to act in the most accurate way on target tissues that can be as small as a few millimetres. The aim of this review is to summarize the local treatments of inflammatory and degenerative disease described in literature (such as treatment of De Quervain's tenosynovitis, trigger finger, trapezio-metacarpal joint osteoarthritis, etc.), emphasizing precautions and tricks based on day-by-day experience that may help to improve the outcome of percutaneous ultrasound-guided procedures around the wrist and hand

  11. Ultrasound-guided procedures around the wrist and hand: How to do

    Energy Technology Data Exchange (ETDEWEB)

    Orlandi, Davide; Corazza, Angelo [Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Genova, Via L.B. Alberti 4, 16132 Genova (Italy); Silvestri, Enzo [Diagnostica per Immagini, Ospedale Evangelico Internazionale, Corso Solferino 29A, 16100 Genova (Italy); Serafini, Giovanni [Dipartimento di Diagnostica per Immagini, Ospedale Santa Corona, Via XXV Aprile 38, 17037 Pietra Ligure, Savona (Italy); Savarino, Edoardo Vincenzo [Dipartimento di Scienze Chirurgiche, Oncologiche e Gastroenterologiche, Università degli Studi di Padova, Via Giustiniani, Padova (Italy); Garlaschi, Giacomo [Dipartimento di Scienze per la Salute, Università degli Studi di Genova, Via L.B. Alberti 4, 16132 Genova (Italy); Mauri, Giovanni [Servizio di Radiologia, IRCCS Policlinico San Donato, Piazza Malan 2, San Donato Milanese, Milano (Italy); Cimmino, Marco Amedeo [Dipartimento di Medicina Interna, Università degli Studi di Genova, Via L.B. Alberti 4, 16132 Genova (Italy); Sconfienza, Luca Maria, E-mail: io@lucasconfienza.it [Servizio di Radiologia, IRCCS Policlinico San Donato, Piazza Malan 2, San Donato Milanese, Milano (Italy); Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Piazza Malan 2, San Donato Milanese, Milano (Italy)

    2014-07-15

    Ultrasound has emerged as a low-cost, radiation-free and effective imaging technique to detect joint abnormalities and to guide percutaneous procedures. Being superficial, wrist and hand tendons and joints represent a good target to perform such procedures using ultrasound guidance. This kind of approach allows for a clear and real-time visualization of the needles during their whole path. In this setting, the knowledge of technical aspects and tips is essential to act in the most accurate way on target tissues that can be as small as a few millimetres. The aim of this review is to summarize the local treatments of inflammatory and degenerative disease described in literature (such as treatment of De Quervain's tenosynovitis, trigger finger, trapezio-metacarpal joint osteoarthritis, etc.), emphasizing precautions and tricks based on day-by-day experience that may help to improve the outcome of percutaneous ultrasound-guided procedures around the wrist and hand.

  12. TU-B-210-00: MR-Guided Focused Ultrasound Therapy in Oncology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advanced techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.

  13. Ultrasound-guided continuous phrenic nerve block for persistent hiccups.

    NARCIS (Netherlands)

    Renes, S.H.; Geffen, G.J. van; Rettig, H.C.; Gielen, M.J.M.; Scheffer, G.J.

    2010-01-01

    BACKGROUND: Phrenic nerve block can be performed and repeated if necessary for persistent hiccups, when conservative and pharmacological treatment is unsuccessful. We report the first description of an in-plane ultrasound (US)-guided phrenic nerve block (PhNB) with a catheter, after US investigation

  14. Evaluation of tomosynthesis elastography in a breast-mimicking phantom

    International Nuclear Information System (INIS)

    Engelken, Florian Jan; Sack, Ingolf; Klatt, Dieter; Fischer, Thomas; Fallenberg, Eva Maria; Bick, Ulrich; Diekmann, Felix

    2012-01-01

    Objective: To evaluate whether measurement of strain under static compression in tomosynthesis of a breast-mimicking phantom can be used to distinguish tumor-simulating lesions of different elasticities and to compare the results to values predicted by rheometric analysis as well as results of ultrasound elastography. Materials and methods: We prepared three soft breast-mimicking phantoms containing simulated tumors of different elasticities. The phantoms were imaged using a wide angle tomosynthesis system with increasing compression settings ranging from 0 N to 105 N in steps of 15 N. Strain of the inclusions was measured in two planes using a commercially available mammography workstation. The elasticity of the phantom matrix and inclusion material was determined by rheometric analysis. Ultrasound elastography of the inclusions was performed using two different ultrasound elastography algorithms. Results: Strain at maximal compression was 24.4%/24.5% in plane 1/plane 2, respectively, for the soft inclusion, 19.6%/16.9% for the intermediate inclusion, and 6.0%/10.2% for the firm inclusion. The strain ratios predicted by rheometrical testing were 0.41, 0.83 and 1.26 for the soft, intermediate, and firm inclusions, respectively. The strain ratios obtained for the soft, intermediate, and firm inclusions were 0.72 ± 0.13, 1.02 ± 0.21 and 2.67 ± 1.70, respectively for tomosynthesis elastography, 0.91, 1.64 and 2.07, respectively, for ultrasound tissue strain imaging, and 0.97, 2.06 and 2.37, respectively, for ultrasound real-time elastography. Conclusions: Differentiation of tumor-simulating inclusions by elasticity in a breast mimicking phantom may be possible by measuring strain in tomosynthesis. This method may be useful for assessing elasticity of breast lesions tomosynthesis of the breast

  15. Experimental investigations of an endoluminal ultrasound applicator for MR-guided thermal therapy of pancreatic cancer

    Science.gov (United States)

    Adams, Matthew; Salgaonkar, Vasant; Jones, Peter; Plata, Juan; Chen, Henry; Pauly, Kim Butts; Sommer, Graham; Diederich, Chris

    2017-03-01

    An MR-guided endoluminal ultrasound applicator has been proposed for palliative and potential curative thermal therapy of pancreatic tumors. Minimally invasive ablation or hyperthermia treatment of pancreatic tumor tissue would be performed with the applicator positioned in the gastrointestinal (GI) lumen, and sparing of the luminal tissue would be achieved with a water-cooled balloon surrounding the ultrasound transducers. This approach offers the capability of conformal volumetric therapy for fast treatment times, with control over the 3D spatial deposition of energy. Prototype endoluminal ultrasound applicators have been fabricated using 3D printed fixtures that seat two 3.2 or 5.6 MHz planar or curvilinear transducers and contain channels for wiring and water flow. Spiral surface coils have been integrated onto the applicator body to allow for device localization and tracking for therapies performed under MR guidance. Heating experiments with a tissue-mimicking phantom in a 3T MR scanner were performed and demonstrated capability of the prototype to perform volumetric heating through duodenal luminal tissue under real-time PRF-based MR temperature imaging (MRTI). Additional experiments were performed in ex vivo pig carcasses with the applicator inserted into the esophagus and aimed towards liver or soft tissue surrounding the spine under MR guidance. These experiments verified the capacity of heating targets up to 20-25 mm from the GI tract. Active device tracking and automated prescription of imaging and temperature monitoring planes through the applicator were made possible by using Hadamard encoded tracking sequences to obtain the coordinates of the applicator tracking coils. The prototype applicators have been integrated with an MR software suite that performs real-time device tracking and temperature monitoring.

  16. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  17. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  18. Ultrasound guided aspiration of breast abscess as an alternative to surgical incision and drainage

    International Nuclear Information System (INIS)

    Naper, M.A.; Shaikh, M.S.; Dholia, K.R.

    2017-01-01

    To evaluate the outcome and assess the success rate of ultrasound guided aspiration of breast abscess as an alternative to surgical incision and drainage. Methodology: A prospective descriptive study was carried out at Department of Surgery, Chandka Medical College Hospital, Larkana, Pakistan, from January 2015 to December 2015. A total of 111 patients of breast abscess who underwent ultrasound guided aspiration without anesthesias with oral antibiotic cover were studied. Females with breast abscess within seven days, and the abscess size was <3cm were included in the study. Males, antibioma and inflammatory carcinoma were excluded from the study. Outcome of success or failure was observed within two weeks and recorded. Results: Out of 111 patients, 68.46% were lactating and 31.53% were non-lactating women, with ages ranging from 18 to 60 years (mean 36.5 years). The successful rate with complete resolution after ultrasound guided aspiration was observed in 94.5%. 80.82% responded after single aspiration, 12.38% after two times aspiration, and 6.66% after multiple aspirations, while 5.4% of patients required incision and drainage. Conclusion: Ultrasound guided aspiration of breast abscess is an effective treatment option with a diameter of <3cm, which can be recommended as a routine outpatient procedure. (author)

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  20. Correction of Non-Linear Propagation Artifact in Contrast-Enhanced Ultrasound Imaging of Carotid Arteries: Methods and in Vitro Evaluation.

    Science.gov (United States)

    Yildiz, Yesna O; Eckersley, Robert J; Senior, Roxy; Lim, Adrian K P; Cosgrove, David; Tang, Meng-Xing

    2015-07-01

    Non-linear propagation of ultrasound creates artifacts in contrast-enhanced ultrasound images that significantly affect both qualitative and quantitative assessments of tissue perfusion. This article describes the development and evaluation of a new algorithm to correct for this artifact. The correction is a post-processing method that estimates and removes non-linear artifact in the contrast-specific image using the simultaneously acquired B-mode image data. The method is evaluated on carotid artery flow phantoms with large and small vessels containing microbubbles of various concentrations at different acoustic pressures. The algorithm significantly reduces non-linear artifacts while maintaining the contrast signal from bubbles to increase the contrast-to-tissue ratio by up to 11 dB. Contrast signal from a small vessel 600 μm in diameter buried in tissue artifacts before correction was recovered after the correction. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS

  2. Advanced 3D Mesh Manipulation in Stereolithographic Files and Post-Print Processing for the Manufacturing of Patient-Specific Vascular Flow Phantoms.

    Science.gov (United States)

    O'Hara, Ryan P; Chand, Arpita; Vidiyala, Sowmya; Arechavala, Stacie M; Mitsouras, Dimitrios; Rudin, Stephen; Ionita, Ciprian N

    2016-02-27

    Complex vascular anatomies can cause the failure of image-guided endovascular procedures. 3D printed patient-specific vascular phantoms provide clinicians and medical device companies the ability to preemptively plan surgical treatments, test the likelihood of device success, and determine potential operative setbacks. This research aims to present advanced mesh manipulation techniques of stereolithographic (STL) files segmented from medical imaging and post-print surface optimization to match physiological vascular flow resistance. For phantom design, we developed three mesh manipulation techniques. The first method allows outlet 3D mesh manipulations to merge superfluous vessels into a single junction, decreasing the number of flow outlets and making it feasible to include smaller vessels. Next we introduced Boolean operations to eliminate the need to manually merge mesh layers and eliminate errors of mesh self-intersections that previously occurred. Finally we optimize support addition to preserve the patient anatomical geometry. For post-print surface optimization, we investigated various solutions and methods to remove support material and smooth the inner vessel surface. Solutions of chloroform, alcohol and sodium hydroxide were used to process various phantoms and hydraulic resistance was measured and compared with values reported in literature. The newly mesh manipulation methods decrease the phantom design time by 30 - 80% and allow for rapid development of accurate vascular models. We have created 3D printed vascular models with vessel diameters less than 0.5 mm. The methods presented in this work could lead to shorter design time for patient specific phantoms and better physiological simulations.

  3. Rapid prototyping of biomimetic vascular phantoms for hyperspectral reflectance imaging

    Science.gov (United States)

    Ghassemi, Pejhman; Wang, Jianting; Melchiorri, Anthony J.; Ramella-Roman, Jessica C.; Mathews, Scott A.; Coburn, James C.; Sorg, Brian S.; Chen, Yu; Joshua Pfefer, T.

    2015-01-01

    Abstract. The emerging technique of rapid prototyping with three-dimensional (3-D) printers provides a simple yet revolutionary method for fabricating objects with arbitrary geometry. The use of 3-D printing for generating morphologically biomimetic tissue phantoms based on medical images represents a potentially major advance over existing phantom approaches. Toward the goal of image-defined phantoms, we converted a segmented fundus image of the human retina into a matrix format and edited it to achieve a geometry suitable for printing. Phantoms with vessel-simulating channels were then printed using a photoreactive resin providing biologically relevant turbidity, as determined by spectrophotometry. The morphology of printed vessels was validated by x-ray microcomputed tomography. Channels were filled with hemoglobin (Hb) solutions undergoing desaturation, and phantoms were imaged with a near-infrared hyperspectral reflectance imaging system. Additionally, a phantom was printed incorporating two disjoint vascular networks at different depths, each filled with Hb solutions at different saturation levels. Light propagation effects noted during these measurements—including the influence of vessel density and depth on Hb concentration and saturation estimates, and the effect of wavelength on vessel visualization depth—were evaluated. Overall, our findings indicated that 3-D-printed biomimetic phantoms hold significant potential as realistic and practical tools for elucidating light–tissue interactions and characterizing biophotonic system performance. PMID:26662064

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  5. HIFU procedures at moderate intensities-effect of large blood vessels

    International Nuclear Information System (INIS)

    Hariharan, P; Myers, M R; Banerjee, R K

    2007-01-01

    A three-dimensional computational model is presented for studying the efficacy of high-intensity focused ultrasound (HIFU) procedures targeted near large blood vessels. The analysis applies to procedures performed at intensities below the threshold for cavitation, boiling and highly nonlinear propagation, but high enough to increase tissue temperature a few degrees per second. The model is based upon the linearized KZK equation and the bioheat equation in tissue. In the blood vessel the momentum and energy equations are satisfied. The model is first validated in a tissue phantom, to verify the absence of bubble formation and nonlinear effects. Temperature rise and lesion-volume calculations are then shown for different beam locations and orientations relative to a large vessel. Both single and multiple ablations are considered. Results show that when the vessel is located within about a beam width (few mm) of the ultrasound beam, significant reduction in lesion volume is observed due to blood flow. However, for gaps larger than a beam width, blood flow has no major effect on the lesion formation. Under the clinically representative conditions considered, the lesion volume is reduced about 40% (relative to the no-flow case) when the beam is parallel to the blood vessel, compared to about 20% for a perpendicular orientation. Procedures involving multiple ablation sites are affected less by blood flow than single ablations. The model also suggests that optimally focused transducers can generate lesions that are significantly larger (>2 times) than the ones produced by highly focused beams

  6. HIFU procedures at moderate intensities-effect of large blood vessels

    Energy Technology Data Exchange (ETDEWEB)

    Hariharan, P [Mechanical, Industrial, and Nuclear Engineering Department, University of Cincinnati, Cincinnati, OH (United States); Myers, M R [Division of Solid and Fluid Mechanics, Center for Devices and Radiological Health, US Food and Drug Administration, 10903 New Hampshire Avenue, Building 62, Silver Spring, MD 20993-0002 (United States); Banerjee, R K [Mechanical, Industrial, and Nuclear Engineering Department, University of Cincinnati, Cincinnati, OH (United States)

    2007-07-21

    A three-dimensional computational model is presented for studying the efficacy of high-intensity focused ultrasound (HIFU) procedures targeted near large blood vessels. The analysis applies to procedures performed at intensities below the threshold for cavitation, boiling and highly nonlinear propagation, but high enough to increase tissue temperature a few degrees per second. The model is based upon the linearized KZK equation and the bioheat equation in tissue. In the blood vessel the momentum and energy equations are satisfied. The model is first validated in a tissue phantom, to verify the absence of bubble formation and nonlinear effects. Temperature rise and lesion-volume calculations are then shown for different beam locations and orientations relative to a large vessel. Both single and multiple ablations are considered. Results show that when the vessel is located within about a beam width (few mm) of the ultrasound beam, significant reduction in lesion volume is observed due to blood flow. However, for gaps larger than a beam width, blood flow has no major effect on the lesion formation. Under the clinically representative conditions considered, the lesion volume is reduced about 40% (relative to the no-flow case) when the beam is parallel to the blood vessel, compared to about 20% for a perpendicular orientation. Procedures involving multiple ablation sites are affected less by blood flow than single ablations. The model also suggests that optimally focused transducers can generate lesions that are significantly larger (>2 times) than the ones produced by highly focused beams.

  7. WE-EF-210-06: Ultrasound 2D Strain Measurement of Radiation-Induced Toxicity: Phantom and Ex Vivo Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Liu, T; Torres, M; Rossi, P; Jani, A; Curran, W; Yang, X [Emory Univ, Atlanta, GA (United States)

    2015-06-15

    Purpose: Radiation-induced fibrosis is a common long-term complication affecting many patients following cancer radiotherapy. Standard clinical assessment of subcutaneous fibrosis is subjective and often limited to visual inspection and palpation. Ultrasound strain imaging describes the compressibility (elasticity) of biological tissues. This study’s purpose is to develop a quantitative ultrasound strain imaging that can consistently and accurately characterize radiation-induce fibrosis. Methods: In this study, we propose a 2D strain imaging method based on deformable image registration. A combined affine and B-spline transformation model is used to calculate the displacement of tissue between pre-stress and post-stress B-mode image sequences. The 2D displacement is estimated through a hybrid image similarity measure metric, which is a combination of the normalized mutual information (NMI) and normalized sum-of-squared-differences (NSSD). And 2D strain is obtained from the gradient of the local displacement. We conducted phantom experiments under various compressions and compared the performance of our proposed method with the standard cross-correlation (CC)- based method using the signal-to-noise (SNR) and contrast-to-noise (CNS) ratios. In addition, we conducted ex-vivo beef muscle experiment to further validate the proposed method. Results: For phantom study, the SNR and CNS values of the proposed method were significantly higher than those calculated from the CC-based method under different strains. The SNR and CNR increased by a factor of 1.9 and 2.7 comparing to the CC-based method. For the ex-vivo experiment, the CC-based method failed to work due to large deformation (6.7%), while our proposed method could accurately detect the stiffness change. Conclusion: We have developed a 2D strain imaging technique based on the deformable image registration, validated its accuracy and feasibility with phantom and ex-vivo data. This 2D ultrasound strain imaging

  8. Significance of 'Bridging vessel sign' on color Doppler ultrasound in diagnosis of uterine subserosal leiomyoma

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Hee; Lee, Jung Hee; Sohn, Chul Ho; Woo, Seung Koo [Keimyung University School of Medicine, Taegu (Korea, Republic of); Kim, Jung Sik [Radiological Clinic, Taegu (Korea, Republic of)

    2002-06-15

    To evaluate the usefulness of the 'bridging vessel sign' in differentiating uterine subserosal leiomyoma from other pelvic masses mimicking leiomyoma on color Doppler ultrasound. Histologically (n=58) and clinically (n=1) proven 59 masses from 55 women were included in this study. Histologic diagnoses included leiomyoma (n=32) and various kinds of other masses (n=27). On gray scale ultrasound, the size of tumor and presence of the ovaries were recorded. On color Doppler ultrasound, the presence of 'bridging vessel sign', which was defined as a linear vessel demonstrated between the mass and the uterus was documented. Uterine subserosal leiomyoma was diagnosed on the basis of finding this sign, and the diagnostic accuracy of this sign in differentiating subserosal leiomyoma from other pelvic tumors was calculated. In addition, the diagnostic accuracy of this sign combined with the visibility of theopsilateral ovary was compared. The size of subserosal leiomyomas ranged from 4.2 to 22.1 cm (mean, 8.3 cm) while the size of other pelvic masses, from 4.6 to 21.5 cm (mean, 9.6 cm). The 'bridging vessel sign' was demonstrated in thirty of 32 leiomyomas and in three of 27 other pelvis masses. The sensitivity, specificity, accuracy, positive predictive value, and negative value of the 'bridging vessel sign' in the diagnosis of subserosal leiomyoma were 93.8%, 99.9%, 91.5%, 90.9% and 92.3%, respectively. The detection of the ipsilateral ovary was possible in 14 of 30 women with leiomyomas and in four of 25 women with other pelvic masses. The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of this finding in the diagnosis of subserosal leiomyoma were 46.7%, 84.0%, 63.6%, 77.8%, and 56.8%, respectively. 'Bridging vessel sign' can be an useful finding in the differential diagnosis of subserosal leiomyomas from other pelvic masses mimicking leiomyoma.

  9. Design and Production of an Articulating Needle Guide for Ultrasound-Guided Needle Block Manufactured With a Three-Dimensional Printer: Technical Communication.

    Science.gov (United States)

    Bigeleisen, Paul E

    2017-05-15

    Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.

  10. 3D perfused brain phantom for interstitial ultrasound thermal therapy and imaging: design, construction and characterization

    International Nuclear Information System (INIS)

    Martínez, José M; Jarosz, Boguslaw J

    2015-01-01

    Thermal therapy has emerged as an independent modality of treating some tumors. In many clinics the hyperthermia, one of the thermal therapy modalities, has been used adjuvant to radio- or chemotherapy to substantially improve the clinical treatment outcomes. In this work, a methodology for building a realistic brain phantom for interstitial ultrasound low dose-rate thermal therapy of the brain is proposed. A 3D brain phantom made of the tissue mimicking material (TMM) had the acoustic and thermal properties in the 20–32 °C range, which is similar to that of a brain at 37 °C. The phantom had 10–11% by mass of bovine gelatin powder dissolved in ethylene glycol. The TMM sonicated at 1 MHz, 1.6 MHz and 2.5 MHz yielded the amplitude attenuation coefficients of 62  ±  1 dB m −1 , 115  ±  4 dB m −1 and 175  ±  9 dB m −1 , respectively. The density and acoustic speed determination at room temperature (∼24 °C) gave 1040  ±  40 kg m −3 and 1545  ±  44 m s −1 , respectively. The average thermal conductivity was 0.532 W m −1  K −1 . The T1 and T2 values of the TMM were 207  ±  4 and 36.2  ±  0.4 ms, respectively. We envisage the use of our phantom for treatment planning and for quality assurance in MRI based temperature determination. Our phantom preparation methodology may be readily extended to other thermal therapy technologies. (paper)

  11. Neurologic Outcomes After Low-Volume, Ultrasound-Guided Interscalene Block and Ambulatory Shoulder Surgery.

    Science.gov (United States)

    Rajpal, Gaurav; Winger, Daniel G; Cortazzo, Megan; Kentor, Michael L; Orebaugh, Steven L

    2016-01-01

    Postoperative neurologic symptoms after interscalene block and shoulder surgery have been reported to be relatively frequent. Reports of such symptoms after ultrasound-guided block have been variable. We evaluated 300 patients for neurologic symptoms after low-volume, ultrasound-guided interscalene block and arthroscopic shoulder surgery. Patients underwent ultrasound-guided interscalene block with 16 to 20 mL of 0.5% bupivacaine or a mix of 0.2% bupivacaine/1.2% mepivacaine solution, followed by propofol/ketamine sedation for ambulatory arthroscopic shoulder surgery. Patients were called at 10 days for evaluation of neurologic symptoms, and those with persistent symptoms were called again at 30 days, at which point neurologic evaluation was initiated. Details of patient demographics and block characteristics were collected to assess any association with persistent neurologic symptoms. Six of 300 patients reported symptoms at 10 days (2%), with one of these patients having persistent symptoms at 30 days (0.3%). This was significantly lower than rates of neurologic symptoms reported in preultrasound investigations with focused neurologic follow-up and similar to other studies performed in the ultrasound era. There was a modest correlation between the number of needle redirections during the block procedure and the presence of postoperative neurologic symptoms. Ultrasound guidance of interscalene block with 16- to 20-mL volumes of local anesthetic solution results in a lower frequency of postoperative neurologic symptoms at 10 and 30 days as compared with investigations in the preultrasound period.

  12. Ultrasound-guided percutaneous cholecysto-cholangiography for the exclusion of biliary atresia in infants

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Kyung Min; Ryeom, Hun Kyu; Choe, Byung Ho; Kim, Kap Cheol; Kim, Jong Yeol; Lee, Jong Min; Kim, Hye Jeong; Lee, Hee Jung [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2006-08-15

    The aim of this study is to determine the feasibility and effectiveness of performing an ultrasound-guided percutaneous cholecysto-cholangiogram (PCC) for excluding biliary atresia as the cause of neonatal jaundice. Between Oct. 2003 and Feb. 2005, six ultrasound-guided PCC procedures were performed to five jaundiced infants (4 females and 1 male; mean age: 60 days old) for whom possibility of biliary atresia could not be ruled out by the DISIDA scan as the cause of their neonatal jaundice. Gallbladder puncture was performed under ultrasound guidance with a 23-gauge needle. Contrast material injection during fluoroscopic examination was performed after dilatation of the gallbladder lumen with normal saline under ultrasound guidance. The criteria used for excluding biliary atresia were complete visualization of the extrahepatic biliary trees and/or contrast excretion into the duodenum. The complications and final diagnosis was assessed according to the clinical and laboratory findings. The procedures were successful in all the patients without any complication. Biliary atresia could be ruled out in all the patients. The final diagnosis was neonatal cytomegalovirus hepatitis in two patients, total parenteral nutrition-associated cholestasis in two patients, and combined cytomegalovirus hepatitis and total parenteral nutrition-associated cholestasis in one patient. Ultrasound-guided PCC is a feasible and effective method for the early definitive exclusion of biliary atresia as the cause of neonatal jaundice. By the technique of injecting normal saline before contrast injection, PCC can be done even in a totally collapsed or very small gallbladder.

  13. Ultrasound-guided percutaneous cholecysto-cholangiography for the exclusion of biliary atresia in infants

    International Nuclear Information System (INIS)

    Shin, Kyung Min; Ryeom, Hun Kyu; Choe, Byung Ho; Kim, Kap Cheol; Kim, Jong Yeol; Lee, Jong Min; Kim, Hye Jeong; Lee, Hee Jung

    2006-01-01

    The aim of this study is to determine the feasibility and effectiveness of performing an ultrasound-guided percutaneous cholecysto-cholangiogram (PCC) for excluding biliary atresia as the cause of neonatal jaundice. Between Oct. 2003 and Feb. 2005, six ultrasound-guided PCC procedures were performed to five jaundiced infants (4 females and 1 male; mean age: 60 days old) for whom possibility of biliary atresia could not be ruled out by the DISIDA scan as the cause of their neonatal jaundice. Gallbladder puncture was performed under ultrasound guidance with a 23-gauge needle. Contrast material injection during fluoroscopic examination was performed after dilatation of the gallbladder lumen with normal saline under ultrasound guidance. The criteria used for excluding biliary atresia were complete visualization of the extrahepatic biliary trees and/or contrast excretion into the duodenum. The complications and final diagnosis was assessed according to the clinical and laboratory findings. The procedures were successful in all the patients without any complication. Biliary atresia could be ruled out in all the patients. The final diagnosis was neonatal cytomegalovirus hepatitis in two patients, total parenteral nutrition-associated cholestasis in two patients, and combined cytomegalovirus hepatitis and total parenteral nutrition-associated cholestasis in one patient. Ultrasound-guided PCC is a feasible and effective method for the early definitive exclusion of biliary atresia as the cause of neonatal jaundice. By the technique of injecting normal saline before contrast injection, PCC can be done even in a totally collapsed or very small gallbladder

  14. Augmented Reality Using Transurethral Ultrasound for Laparoscopic Radical Prostatectomy: Preclinical Evaluation.

    Science.gov (United States)

    Lanchon, Cecilia; Custillon, Guillaume; Moreau-Gaudry, Alexandre; Descotes, Jean-Luc; Long, Jean-Alexandre; Fiard, Gaelle; Voros, Sandrine

    2016-07-01

    To guide the surgeon during laparoscopic or robot-assisted radical prostatectomy an innovative laparoscopic/ultrasound fusion platform was developed using a motorized 3-dimensional transurethral ultrasound probe. We present what is to our knowledge the first preclinical evaluation of 3-dimensional prostate visualization using transurethral ultrasound and the preliminary results of this new augmented reality. The transurethral probe and laparoscopic/ultrasound registration were tested on realistic prostate phantoms made of standard polyvinyl chloride. The quality of transurethral ultrasound images and the detection of passive markers placed on the prostate surface were evaluated on 2-dimensional dynamic views and 3-dimensional reconstructions. The feasibility, precision and reproducibility of laparoscopic/transurethral ultrasound registration was then determined using 4, 5, 6 and 7 markers to assess the optimal amount needed. The root mean square error was calculated for each registration and the median root mean square error and IQR were calculated according to the number of markers. The transurethral ultrasound probe was easy to manipulate and the prostatic capsule was well visualized in 2 and 3 dimensions. Passive markers could precisely be localized in the volume. Laparoscopic/transurethral ultrasound registration procedures were performed on 74 phantoms of various sizes and shapes. All were successful. The median root mean square error of 1.1 mm (IQR 0.8-1.4) was significantly associated with the number of landmarks (p = 0.001). The highest accuracy was achieved using 6 markers. However, prostate volume did not affect registration precision. Transurethral ultrasound provided high quality prostate reconstruction and easy marker detection. Laparoscopic/ultrasound registration was successful with acceptable mm precision. Further investigations are necessary to achieve sub mm accuracy and assess feasibility in a human model. Copyright © 2016 American Urological

  15. Ultrasound-guided percutaneous drainage of meniscal cysts: preliminary clinical experience

    International Nuclear Information System (INIS)

    MacMahon, P.J.; Brennan, D.D.; Duke, D.; Forde, S.; Eustace, S.J.

    2007-01-01

    Aim: To evaluate the efficacy of ultrasound-guided percutaneous drainage of symptomatic meniscal cysts. Materials and methods: Patients with lateral knee joint tenderness and swelling and confirmed meniscal cyst on magnetic resonance imaging (MRI) were consecutively enrolled for ultrasound-guided percutaneous cyst aspiration. Cysts were injected with local anaesthetic and steroid before completion of procedure. All 18 patients (all male, average age 33 years) were subsequently followed up (average time 10 months) and meniscal cyst symptoms assessed by questionnaire. Fischer's exact test used to analyse the data. Results: In every case the procedure was well tolerated, and each patient indicated that they would be willing to have a repeat procedure in the future. Ten patients reported complete resolution of symptoms secondary to therapeutic cyst aspiration and had resumed participation in high-performance sport. Two patients reported a satisfactory sustained response, reporting only occasional 'twinges of pain'. In the remaining six patients, symptoms returned after an initial pain-free period. The pain-free period ranged from 1-8 weeks. In this study, patient outcome did not significantly correlate with any meniscal cyst characteristic. Conclusion: Ultrasound-guided percutaneous aspiration of meniscal cysts is a well-tolerated, simple, and safe procedure. In this small patient series, it was associated with positive early results with favourable outcomes in the mid to long-term. It should be considered in patients unsuitable for surgical debridement or as an interim therapy if surgery is delayed or postponed

  16. Gestrinone combined with ultrasound-guided aspiration and ethanol injection for treatment of chocolate cyst of ovary.

    Science.gov (United States)

    Wu, Xiaoyun; Xu, Yun

    2015-05-01

    The aim of this study was to determine clinical performance of gestrinone combined with ultrasound-guided aspiration and ethanol injection in treating chocolate cyst of ovary. Sixty-eight patients enrolled in this study were randomly divided into two groups: control group and combination treatment group. In the control group, 34 patients were treated with ultrasound-guided aspiration and ethanol injection. In the combination treatment group, 34 patients received gestrinone p.o. following ultrasound-guided aspiration and ethanol injection. The recurrence rate of chocolate cyst was 10-fold lower in the combination treatment group (2.94%, 1/34) than in the control group (29.4%, 10/34) at 12 months. The effective rate for reduction of chocolate cyst was significantly higher in the combination treatment group (94.12%, 32/34) than in the control group (64.71%, 22/34) (P = 0.009). Gestrinone combined with ultrasound-guided aspiration and ethanol injection therapy is an effective treatment for ovarian chocolate cyst with low recurrence rate. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  17. Ultrasound-Guided Percutaneous Drainage of Neonatal Pyometrocolpos Under Local Anesthesia

    International Nuclear Information System (INIS)

    Algin, Oktay; Erdogan, Cuneyt; Kilic, Nizamettin

    2011-01-01

    Hydrometrocolpos is an uncommon congenital disorder with cystic dilatation of the vagina and uterus that occurs as a result of accumulated secretions from the reproductive tract due to distal genital tract obstruction. Secondary infection may also occur, resulting in pyometrocolpos, a potentially lethal disease. Immediate drainage of the cystic mass in patients determined to have pyometrocolpos is required to prevent or treat uropathy and septicemia until definitive corrective surgery can be performed. We report an unusual cause of obstructive uropathy in three infants: pyometrocolpos due to lower genital tract atresia. Ultrasound-guided percutaneous drainage of the pyometrocolpos resulted in dramatically improved clinical and laboratory findings in these patients. Ultrasound-guided percutaneous drainage under local anesthesia is a simple, minimally invasive, safe, and effective procedure that facilitates later successful corrective surgery and avoids the need for more complex drainage procedures.

  18. Efficacy of Ablation Therapy for Secondary Hyperparathyroidism by Ultrasound Guided Percutaneous Thermoablation.

    Science.gov (United States)

    Zhao, Junfeng; Qian, Linxue; Zu, Yuan; Wei, Ying; Hu, Xiangdong

    2016-05-01

    The objective of this study was to explore the value of ultrasound-guided percutaneous microwave thermoablation to treat secondary hyperparathyroidism (SHPT). One hundred and thirty-eight parathyroid glands from 56 patients with SHPT were ablated in this study. All the parathyroid glands were evaluated by real-time contrast-enhanced ultrasound before, during and after ablation. Changes in serum parathyroid hormone (sPTH) levels were measured before treatment and at 1 h, 1 wk, 1 mo and 6 mo after thermoablation treatment. All 56 cases had a 1-mo follow-up, and 34 cases had a 6-mo follow-up. The sPTH level of the 54 cases 1 mo after ablation was significantly lower than that before (p 0.05). Ultrasound-guided percutaneous microwave thermoablation is a feasible and effective non-surgical alternative treatment for SHPT patients. Copyright © 2016. Published by Elsevier Inc.

  19. Quality assessment of ultrasonographic equipment using an ATS-539 multipurpose phantom

    International Nuclear Information System (INIS)

    Kim, Pyo Nyun; Lim, Joo Won; Kim, Hyun Cheol; Yoon, Young Cheol; Sung, Deuk Je; Moon, Min Hoan; Kim, Jeong Sook; Kim, Jong Chan

    2008-01-01

    To determine the rate of congruence and to standardize assessment of US (ultrasound) phantom images with the use of an ATS-539 multipurpose phantom for US equipment currently utilized in Korea. US phantom images were scanned with a 3.0-5.0 MHz convex transducer and were digitized by use of an analogue-digital converter. Members of a committee with consent evaluated the US phantom images from 108 types of ultrasound equipment. The dead zone, vertical and horizontal measurement, axial/lateral resolution, focal zone, sensitivity, functional resolution and gray scale/dynamic range were evaluated. Congruence or incongruence of ultrasound equipment was determined based on the results of dead zone, axial/lateral resolution and gray scale/dynamic range measurements. Other factors were evaluated for the possibility as criteria with the use of the Mann-Whitney U test and receiver operator characteristic (ROC) curve analysis. The dead zone, axial/lateral resolution and gray scale/dynamic range were 91.7%, 94.4% and 76.9%, respectively, for suitable US equipment. Considering all three factors, 78 types of ultrasound equipment were passed. The congruence rate of focal zone and functional resolution were 62.4% and 69.3% of the US equipment, respectively. Of the US equipment, 72.2% of the equipment was acceptable based on the dead zone, axial/lateral resolution, and gray scale/dynamic range measurement as determined with the use of an ATS-539 phantom. Focal zone and 8 mm-functional resolution can be useful as a standard in the assessment of a US phantom image

  20. Imprint cytology from ultrasound-guided core biopsies: accurate and immediate diagnosis in a one-stop breast clinic

    International Nuclear Information System (INIS)

    Jones, L.; Lott, M.F.; Calder, C.J.; Kutt, E.

    2004-01-01

    AIM: To investigate whether imprint cytology from ultrasound-guided core biopsy specimens was adequate for the National Health Service Breast Screening Programme (NHSBSP) guidelines. METHODS: We prospectively audited imprint cytology from ultrasound-guided core biopsy specimens. The performance indicators for imprint cytology specimens from 111 consecutive ultrasound-guided core biopsy were compared with standards set by the NHSBSP for fine-needle aspiration cytology (FNAC). RESULTS: Imprint cytology fulfilled the 'preferred' targets for absolute and complete sensitivity, specificity, positive predictive value, false-positive and false-negative rates, inadequate rate and inadequate rate from cancers. It also satisfied the minimum target for suspicious rate. The complete sensitivity was 97%, full specificity 78%, with 100% positive predictive value for C5 cytology and an inadequate rate from cancers of 1.5%. CONCLUSION: Imprint cytology from ultrasound-guided core biopsy allows same-day diagnosis and the collection of data regarding the grade of the carcinoma for treatment decisions from a single needle test

  1. Ultrasound-guided supra-acetabular pin placement in pelvic external fixation: description of a surgical technique and results.

    Science.gov (United States)

    Chana-Rodríguez, Francisco; Cuervas-Mons, Manuel; Rojo-Manaute, José; Mora, Félix; Arnal, Juan; Vaquero-Martín, Javier

    2017-11-01

    Pelvic fracture in trauma patients can lead to hemodynamic instability. External fixation is a treatment capable of stabilizing these injuries in the context of damage control surgery. Supra-acetabular pin offers the greater biomechanical stability but requires the use of intraoperative fluoroscopy. The aim of this study was to analyze our results for an ultrasound-guided supra-acetabular pinning. Cross-sectional study with cadaveric specimens. Ultrasound-guided pin placement assessed by fluoroscopy and dissection. Fourteen ultrasound-guided supra-acetabular pins were placed in seven cadaveric specimens. Excellent placement in all cases, evaluated with radiological control. Good qualitative bone fixation after dissection. One femoral cutaneous nerve was not found during anatomic dissection and was assumed injured. Ultrasound-guided supra-acetabular pin placement is a feasible and effective technique. Our study indicates that pin placement without intraoperative fluoroscopy is feasible without compromising the reliability of its placement. © 2017 Elsevier Ltd. All rights reserved.

  2. Ultrasound-guided versus fluoroscopy-guided sacroiliac joint intra-articular injections in the noninflammatory sacroiliac joint dysfunction: a prospective, randomized, single-blinded study.

    Science.gov (United States)

    Jee, Haemi; Lee, Ji-Hae; Park, Ki Deok; Ahn, Jaeki; Park, Yongbum

    2014-02-01

    To compare the short-term effects and safety of ultrasound (US)-guided sacroiliac joint (SIJ) injections with fluoroscopy (FL)-guided SIJ injections in patients with noninflammatory SIJ dysfunction. Prospective, randomized controlled trial. University hospital. Patients (N=120) with noninflammatory sacroiliac arthritis were enrolled. All procedures were performed using an FL or US apparatus. Subjects were randomly assigned to either the FL or US group. Immediately after the SIJ injections, fluoroscopy was applied to verify the correct placement of the injected medication and intravascular injections. Treatment effects and functional improvement were compared at 2 and 12 weeks after the procedures. The verbal numeric pain scale and Oswestry Disability Index improved at 2 and 12 weeks after the injections without statistical significances between groups. Of 55 US-guided injections, 48 (87.3%) were successful and 7 (12.7%) were missed. The FL-guided SIJ approach exhibited a greater accuracy (98.2%) than the US-guided approach. Vascularization around the SIJ was seen in 34 of 55 patients. Among the 34 patients, 7 had vascularization inside the joint, 23 had vascularization around the joint, and 4 had vascularization both inside and around the joint. Three cases of intravascular injections occurred in the FL group. The US-guided approach may facilitate the identification and avoidance of the critical vessels around or within the SIJ. Function and pain relief significantly improved in both groups without significant differences between groups. The US-guided approach was shown to be as effective as the FL-guided approach in treatment effects. However, diagnostic application in the SIJ may be limited because of the significantly lower accuracy rate (87.3%). Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  3. Septic bursitis after ultrasound-guided percutaneous treatment of rotator cuff calcific tendinopathy.

    Science.gov (United States)

    Sconfienza, Luca Maria; Randelli, Filippo; Sdao, Silvana; Sardanelli, Francesco; Randelli, Pietro

    2014-08-01

    Calcific tendinopathy of the rotator cuff is a common condition. Ultrasound-guided percutaneous aspiration is one of several options to treat this condition. The main advantages of this procedure are short duration, good outcome, and low cost. Furthermore, only minor complications have been reported in the literature, namely, vagal reactions during the procedure and mild postprocedural pain. We report the first case of septic bursitis after ultrasound-guided percutaneous treatment of calcific tendinopathy. Although this is generally considered a very safe procedure, a risk of infection should be taken into account. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  4. Ultrasound-Guided Drainage of Supralevator Hematoma in a Hemodynamically Stable Patient.

    Science.gov (United States)

    Mukhopadhyay, Debjani; Jennings, Paul E; Banerjee, Mamta; Gada, Ruta

    2015-12-01

    Paravaginal hematomas can be life-threatening. In patients with intact vaginal walls and perineum, they may pose a diagnostic and therapeutic challenge. Supralevator hematomas are much less common than infralevator hematomas. We present a case of puerperal hemorrhagic shock after a normal vaginal delivery in a low-risk parous woman resulting from an occult supralevator hematoma. Because the woman was hemodynamically unstable initially, she underwent a vaginal surgical drainage. A week later, the supravaginal hematoma reformed. At this time the patient was hemodynamically stable, and ultrasound-guided drainage was performed, which resulted in complete resolution of the hematoma within 10 days. In a clinically stable puerperal patient, ultrasound-guided drainage of a supralevator hematoma resulted in rapid and complete resolution of symptoms.

  5. How to achieve ultrasound-guided femoral venous access: the new standard of care in the electrophysiology laboratory.

    Science.gov (United States)

    Wiles, Benedict M; Child, Nicholas; Roberts, Paul R

    2017-06-01

    Bedside vascular ultrasound machines are increasingly available. They are used to facilitate safer vascular access across a number of different specialties. In the electrophysiology laboratory however, where patients are frequently anticoagulated and require the insertion of multiple venous sheaths, anatomical landmark techniques predominate. Despite the high number of vascular complications associated with electrophysiological procedures and the increasing evidence to support its use in electrophysiology, ultrasound remains underutilised. A new standard of care is required. A comprehensive technical report, providing a detailed explanation of this important technique, will provide other electrophysiology centres with the knowledge and justification for adopting ultrasound guidance as their standard practice. We review the increasing body of evidence which demonstrates that routine ultrasound usage can substantially improve the safety of femoral venous access in the electrophysiology laboratory. We offer a comprehensive technical report to guide operators through the process of ultrasound-guided venous access, with a specific focus on the electrophysiology laboratory. Additionally, we detail a novel technique which utilises real-time colour Doppler ultrasound to accurately identify needle tip location during venous puncture. The use of vascular ultrasound to guide femoral venous cannulation is rapid, inexpensive and easily learnt. Ultrasound is readily available and offers the potential to significantly reduce vascular complications in the unique setting of the electrophysiology laboratory. Ultrasound guidance to achieve femoral venous access should be the new standard of care in electrophysiology.

  6. The effect of magnetic nanoparticles on the acoustic properties of tissue-mimicking agar-gel phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Józefczak, A., E-mail: aras@amu.edu.pl [Institute of Acoustics, Faculty of Physics, Adam Mickiewicz University, Poznań (Poland); Kaczmarek, K. [Institute of Acoustics, Faculty of Physics, Adam Mickiewicz University, Poznań (Poland); Kubovčíková, M. [Institute of Experimental Physics, Slovak Academy of Sciences, Košice (Slovakia); Rozynek, Z.; Hornowski, T. [Institute of Acoustics, Faculty of Physics, Adam Mickiewicz University, Poznań (Poland)

    2017-06-01

    In ultrasonic hyperthermia, ultrasound-induced heating is achieved by the absorption of wave energy and its conversion into heat. The effectiveness of ultrasounds can be improved by using sonosensitisers that greatly attenuate ultrasonic waves and then dissipate the acquired energy in the form of heat. One possible candidate for such a sonosensitiser are superparamagnetic iron oxide nanoparticles. Here, we used magnetic nanoparticles embedded in a tissue-mimicking agar-gel matrix. Such tissue-mimicking phantoms possess acoustic properties similar to those of real tissues, and are used as a tool for performance testing and optimisation of medical ultrasound systems. In this work, we studied the effect of magnetic nanoparticles on the acoustic properties of agar-gel phantoms, including the attenuation of ultrasonic waves. - Highlights: • Ultrasonic insertion technique is used to study acoustic properties of agar-gel phantoms with and without magnetic particles. • The addition of magnetic nanoparticles improves effectiveness of ultrasound heating in agar phantoms. • Acoustics properties of a pure agar-gel phantom are altered by adding nanoparticles.

  7. Task-oriented comparison of power spectral density estimation methods for quantifying acoustic attenuation in diagnostic ultrasound using a reference phantom method.

    Science.gov (United States)

    Rosado-Mendez, Ivan M; Nam, Kibo; Hall, Timothy J; Zagzebski, James A

    2013-07-01

    Reported here is a phantom-based comparison of methods for determining the power spectral density (PSD) of ultrasound backscattered signals. Those power spectral density values are then used to estimate parameters describing α(f), the frequency dependence of the acoustic attenuation coefficient. Phantoms were scanned with a clinical system equipped with a research interface to obtain radiofrequency echo data. Attenuation, modeled as a power law α(f)= α0 f (β), was estimated using a reference phantom method. The power spectral density was estimated using the short-time Fourier transform (STFT), Welch's periodogram, and Thomson's multitaper technique, and performance was analyzed when limiting the size of the parameter-estimation region. Errors were quantified by the bias and standard deviation of the α0 and β estimates, and by the overall power-law fit error (FE). For parameter estimation regions larger than ~34 pulse lengths (~1 cm for this experiment), an overall power-law FE of 4% was achieved with all spectral estimation methods. With smaller parameter estimation regions as in parametric image formation, the bias and standard deviation of the α0 and β estimates depended on the size of the parameter estimation region. Here, the multitaper method reduced the standard deviation of the α0 and β estimates compared with those using the other techniques. The results provide guidance for choosing methods for estimating the power spectral density in quantitative ultrasound methods.

  8. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    A retrospective analysis of ultrasound-guided large core needle biopsies of breast lesions at a regional public hospital in Durban, KwaZulu-Natal, South Africa. ... Objective: To assess the influence of technical variables on the diagnostic yield of breast specimens obtained by using US-LCNB, and the sensitivity of detecting ...

  9. A comparison of ultrasound guided fine needle aspiration cytology and core needle biopsy in evaluation of palpable breast lesions

    International Nuclear Information System (INIS)

    Altaf, H.N.; Farooqui, F.

    2015-01-01

    Objective: To compare ultrasound guided fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients presenting with palpable breast lumps (PBLs), in terms of sensitivity and specificity, taking final histopathology as gold standard. Methodology: This cross-sectional study was conducted at Holy Family Hospital, Rawalpindi, Pakistan. Ultrasound guided FNAC and CNB were taken of all female patients with PBLs. The results were compared with final histopathology as gold standard. Data analysis was performed using SPSS software and chi-square test. Results: A total of 60 patients were included in the study. The mean age was 33.8 yrs. The sensitivity and specificity of ultrasound guided FNAC were 68.7% and 93.1%, respectively. The sensitivity and specificity of ultrasound guided CNB was 93.7% and 100%. The accuracy of FNAC was 86.2% and that of core needle biopsy was 98.3%. Conclusion: The ultrasound guided core needle biopsy can be used as an initial diagnostic test for the evaluation of all PBLs. Because of high negative predictive value core needle biopsy can replace surgical excision biopsy for benign lesions. (author)

  10. Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma

    Directory of Open Access Journals (Sweden)

    Vetrivel Chezian Sengodan

    2017-01-01

    Full Text Available Background: The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. Materials and Methods: 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Results: Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side (P < 0.001 at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Conclusion: Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment.

  11. 75 FR 56903 - Pacific Halibut Fisheries; Limited Access for Guided Sport Charter Vessels in Alaska

    Science.gov (United States)

    2010-09-17

    .... 100503209-0430-02] RIN 0648-AY85 Pacific Halibut Fisheries; Limited Access for Guided Sport Charter Vessels... program for charter vessels in the guided sport fishery for Pacific halibut in the waters of International... necessary to achieve the halibut fishery management goals of the North Pacific Fishery Management Council...

  12. Combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures

    International Nuclear Information System (INIS)

    Sommer, C.M.; Huber, J.; Radeleff, B.A.; Hosch, W.; Stampfl, U.; Loenard, B.M.; Hallscheidt, P.; Haferkamp, A.; Kauczor, H.U.; Richter, G.M.

    2011-01-01

    Aim: To report our experience of combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures. Patients and methods: Eighteen patients (23 kidneys) with non-obstructive uropathy due to urine leaks underwent combined CT- and fluoroscopy-guided nephrostomy. All procedures were indicated as second-line interventions after failed ultrasound-guided nephrostomy. Thirteen males and five females with an age of 62.3 ± 8.7 (40–84) years were treated. Urine leaks developed in majority after open surgery, e.g. postoperative insufficiency of ureteroneocystostomy (5 kidneys). The main reasons for failed ultrasound-guided nephrostomy included anatomic obstacles in the puncture tract (7 kidneys), and inability to identify pelvic structures (7 kidneys). CT-guided guidewire placement into the collecting system was followed by fluoroscopy-guided nephrostomy tube positioning. Procedural success rate, major and minor complication rates, CT-views and needle passes, duration of the procedure and radiation dose were analyzed. Results: Procedural success was 91%. Major and minor complication rates were 9% (one septic shock and one perirenal abscess) and 9% (one perirenal haematoma and one urinoma), respectively. 30-day mortality rate was 6%. Number of CT-views and needle passes were 9.3 ± 6.1 and 3.6 ± 2.6, respectively. Duration of the complete procedure was 87 ± 32 min. Dose-length product and dose-area product were 1.8 ± 1.4 Gy cm and 3.9 ± 4.3 Gy cm 2 , respectively. Conclusions: Combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound-guided procedures was feasible with high technical success and a tolerable complication rate.

  13. Guide to the periodic inspection of nuclear reactor steel pressure vessels

    International Nuclear Information System (INIS)

    1969-01-01

    This Guide is intended to provide general information and guidance to reactor owners or operators, inspection authorities, certifying authorities or regulatory bodies who are responsible for establishing inspection procedures for specific reactors or reactor types, and for the preparation of national codes or standards. The recommendations of the Guide apply primarily to water-cooled steel reactor vessels which are at a sufficiently early stage of design so that recommendations to provide accessibility for inspection can be incorporated into the early stages of design and inspection planning. However, much of the contents of the Guide are also applicable in part to vessels for other reactor types, such as gas-cooled, pressure-tube, or liquid-metal-cooled reactors, and also to some existing water-cooled reactors and reactors which are in advanced stage of design or construction. 46 refs, figs, 1 tab

  14. Ultrasound-guided truncal blocks: A new frontier in regional anaesthesia

    Directory of Open Access Journals (Sweden)

    Arunangshu Chakraborty

    2016-01-01

    Full Text Available The practice of regional anaesthesia is rapidly changing with the introduction of ultrasound into the working domain of the anaesthesiologist. New techniques are being pioneered. Among the recent techniques, notable are the truncal blocks, for example, the transversus abdominis plane block, rectus sheath block, hernia block and quadratus lumborum block in the abdomen and the pectoral nerves (Pecs block 1 and 2, serratus anterior plane block and intercostal nerve block. This narrative review covers the brief anatomical discourse along with technical description of the ultrasound-guided truncal blocks.

  15. Approach to treatment for obstructive jaundice of PTCD guided by combining ultrasound with X-ray scan

    International Nuclear Information System (INIS)

    Tang Huanliang; Cao Haoqian; Fei Jianguo

    2008-01-01

    Objective: To investigate the technical and clinical value of PTCD in patients with obstructive jaundice by the guiding of ultrasound combined with X-ray scan. Methods PTCD was performed in 58 patients with obstructive jaundice, with 47 patients malignant diseases and 11 patients benign diseases, guided by combining ultrasound and X-ray scan. 51 patients were punctured to right bile ducts and 7 cases were left bile ducts. Cholangiography was routinely used. Results: Technical success was obtained in all patients. No bleeding and biliary peritonitis were found after procedures. The bilirubin was reduced by 75.4ummol/L one week after operation. Conclusion: The technique of PTCD guided by combining ultrasound with X-ray scan was safe, simple, cost saving and less complications for obstructive jaundice. (authors)

  16. Ultrasound-Guided Bipolar Umbilical Cord Occlusion in Complicated Monochorionic Pregnancies

    DEFF Research Database (Denmark)

    Schou, Katrine V; Jensen, Lisa N; Jørgensen, Connie

    2017-01-01

    INTRODUCTION: Ultrasound-guided bipolar umbilical cord occlusion (UCO) is used in complicated monochorionic multiple pregnancies in Denmark. The aim of this study was to assess a learning curve in the procedure of UCO. MATERIALS AND METHODS: One hundred and two monochorionic pregnancies treated...

  17. Ultrasound-guided injection for plantar fasciitis: A brief review

    Directory of Open Access Journals (Sweden)

    A S Nair

    2016-01-01

    Full Text Available Plantar fasciitis (PF is a distressing condition experienced by many patients. Although self-limiting, it tends to become a chronic ailment if the precipitating factors are not addressed. One of the modality of treating PF is intra-lesional corticosteroid injection. This was done using palpation technique earlier but nowadays many specialists use ultrasound (US imaging as a guide to give injection accurately instead of inadvertently damaging the plantar fascia or injecting into surrounding soft tissue, both of which can have serious implications. We did a literature search in Medline, Scopus, and Embase databases to find out articles describing US-guided corticosteroid injection for treating PF and whether guided injection was effective than injection given by palpation.

  18. Ultrasound/Magnetic Resonance Image Fusion Guided Lumbosacral Plexus Block – A Clinical Study

    DEFF Research Database (Denmark)

    Strid, JM; Pedersen, Erik Morre; Søballe, Kjeld

    2014-01-01

    in a double-blinded randomized controlled trial with crossover design. MR datasets will be acquired and uploaded in an advanced US system (Epiq7, Phillips, Amsterdam, Netherlands). All volunteers will receive SSPS blocks with lidocaine added gadolinium contrast guided by US/MR image fusion and by US one week......Background and aims Ultrasound (US) guided lumbosacral plexus block (Supra Sacral Parallel Shift [SSPS]) offers an alternative to general anaesthesia and perioperative analgesia for hip surgery.1 The complex anatomy of the lumbosacral region hampers the accuracy of the block, but it may be improved...... by guidance of US and magnetic resonance (MR) image fusion and real-time 3D electronic needle tip tracking.2 We aim to estimate the effect and the distribution of lidocaine after SSPS guided by US/MR image fusion compared to SSPS guided by ultrasound. Methods Twenty-four healthy volunteers will be included...

  19. Ultrasound guided aspiration cytology of neck mass except thyroid mass

    International Nuclear Information System (INIS)

    Kim, Myeong Jin; Lee, Jong Tae; Yoo, Hyung Sik; Suh, Jung Ho; Park, Cheong Soo; Lee, Gwang Gil

    1988-01-01

    Results of ultrasound guided aspiration cytology of extrathyroidal neck masses of 73 patients were reviewed. Included cases were 23 malignant lesions; 16 metastatic tumors, 4 lymphomas, 3 salivary gland tumors and 50 benign lesions: 24 tuberculous lymphadenites, 15 abscess, 3 benign lymph node hyperplasias, etc. There were one case of false negative and none of false positive result for malignancy. In two cases of malignancy, insufficient cellular material was obtained. In one case of lymphoma, and a benign lymph node hyperplasia, it was difficult to distinguish between benignancy and malignancy on cytologic smear. For the malignant lesions, sensitivity was 83%, specificity was 98%, and overall accuracy was 93%. There were none who had suffered adverse effect from the procedure. Ultrasound guided aspiration cytology seems to be simple, accurate and safe diagnostic modality for neck masses especially in condition that malignancy can not be excluded

  20. An estimation of the minimum effective anesthetic volume of 2% lidocaine in ultrasound-guided axillary brachial plexus block.

    LENUS (Irish Health Repository)

    O'Donnell, Brian D

    2009-07-01

    Ultrasound guidance facilitates precise needle and injectate placement, increasing axillary block success rates, reducing onset times, and permitting local anesthetic dose reduction. The minimum effective volume of local anesthetic in ultrasound-guided axillary brachial plexus block is unknown. The authors performed a study to estimate the minimum effective anesthetic volume of 2% lidocaine with 1:200,000 epinephrine (2% LidoEpi) in ultrasound-guided axillary brachial plexus block.

  1. Image-guided focused ultrasound ablation of breast cancer: current status, challenges, and future directions

    NARCIS (Netherlands)

    Schmitz, A.C.; Gianfelice, D.; Daniel, B.L.; Mali, W.P.T.M.; Bosch, M.A.A.J. van den

    2008-01-01

    Image-guided focussed ultrasound (FUS) ablation is a noninvasive procedure that has been used for treatment of benign or malignant breast tumours. Image-guidance during ablation is achieved either by using real-time ultrasound (US) or magnetic resonance imaging (MRI). The past decade phase I

  2. Toward a real-time system for temporal enhanced ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Azizi, Shekoofeh; Van Woudenberg, Nathan; Sojoudi, Samira; Li, Ming; Xu, Sheng; Abu Anas, Emran M; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Mousavi, Parvin; Abolmaesumi, Purang

    2018-03-27

    We have previously proposed temporal enhanced ultrasound (TeUS) as a new paradigm for tissue characterization. TeUS is based on analyzing a sequence of ultrasound data with deep learning and has been demonstrated to be successful for detection of cancer in ultrasound-guided prostate biopsy. Our aim is to enable the dissemination of this technology to the community for large-scale clinical validation. In this paper, we present a unified software framework demonstrating near-real-time analysis of ultrasound data stream using a deep learning solution. The system integrates ultrasound imaging hardware, visualization and a deep learning back-end to build an accessible, flexible and robust platform. A client-server approach is used in order to run computationally expensive algorithms in parallel. We demonstrate the efficacy of the framework using two applications as case studies. First, we show that prostate cancer detection using near-real-time analysis of RF and B-mode TeUS data and deep learning is feasible. Second, we present real-time segmentation of ultrasound prostate data using an integrated deep learning solution. The system is evaluated for cancer detection accuracy on ultrasound data obtained from a large clinical study with 255 biopsy cores from 157 subjects. It is further assessed with an independent dataset with 21 biopsy targets from six subjects. In the first study, we achieve area under the curve, sensitivity, specificity and accuracy of 0.94, 0.77, 0.94 and 0.92, respectively, for the detection of prostate cancer. In the second study, we achieve an AUC of 0.85. Our results suggest that TeUS-guided biopsy can be potentially effective for the detection of prostate cancer.

  3. Ultrasound Guided Needle Aspiration versus Surgical Drainage in the management of breast abscesses: a Ugandan experience

    Directory of Open Access Journals (Sweden)

    Chandika Alphonce B

    2012-01-01

    Full Text Available Abstract Background Despite breast abscess becoming less common in developed countries, it has remained one of the leading causes of morbidity in women in developing countries. A randomized controlled trial was conducted at Mulago hospital complex in Kampala Uganda to establish whether ultrasound guided needle aspiration is a feasible alternative treatment option for breast abscesses. Results A total of 65 females with breast abscess were analyzed, of these 33 patients were randomized into the ultrasound guided needle aspiration and 32 patients in the Incision and drainage arm. The mean age was 23.12, most of them were lactating (66.2%, primipararous (44.6% with peripheral abscesses (73.8% located in the upper lateral quadrant (56%.The mean breast size was 3.49 cm. The two groups were comparably in demographic characteristic and breast abscess size. Survival analysis showed no difference in breast abscess healing rate between the two groups (Log rank 0.24 df 1 and P = 0.63. Incision and drainage was found to be more costly than ultrasound guided aspiration (cost effective ratio of 2.85. Conclusion Ultrasound guided needle aspiration is therefore a feasible and cost effective treatment option for both lactating and non lactating breast abscesses with a diameter up to 5 cm by ultrasound in an immune competent patient

  4. Ultrasound assessment of the posterior circumflex humeral artery in elite volleyball players: Aneurysm prevalence, anatomy, branching pattern and vessel characteristics

    OpenAIRE

    van de Pol, Daan; Maas, Mario; Terpstra, Aart; Pannekoek-Hekman, Marja; Alaeikhanehshir, Sena; Kuijer, P. Paul F. M.; Planken, R. Nils

    2016-01-01

    Objectives To determine the prevalence of posterior circumflex humeral artery (PCHA) aneurysms and vessel characteristics of the PCHA and deep brachial artery (DBA) in elite volleyball players. Methods Two-hundred and eighty players underwent standardized ultrasound assessment of the dominant arm by a vascular technologist. Assessment included determination of PCHA aneurysms (defined as segmental vessel dilatation ?150 %), PCHA and DBA anatomy, branching pattern, vessel course and diameter. R...

  5. Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain

    Science.gov (United States)

    Arvanitis, Costas D.; Livingstone, Margaret S.; McDannold, Nathan

    2013-07-01

    Several emerging therapies with potential for use in the brain, harness effects produced by acoustic cavitation—the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood-brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. While preliminary, these data clearly demonstrate, for the first time, that it is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood-brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate that it will also prove to be an important research tool that will

  6. Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain

    International Nuclear Information System (INIS)

    Arvanitis, Costas D; McDannold, Nathan; Livingstone, Margaret S

    2013-01-01

    Several emerging therapies with potential for use in the brain, harness effects produced by acoustic cavitation—the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood–brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. While preliminary, these data clearly demonstrate, for the first time, that it is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood–brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate that it will also prove to be an important research tool that

  7. Novel ultrasound-responsive chitosan/perfluorohexane nanodroplets for image-guided smart delivery of an anticancer agent: Curcumin.

    Science.gov (United States)

    Baghbani, Fatemeh; Chegeni, Mahdieh; Moztarzadeh, Fathollah; Hadian-Ghazvini, Samaneh; Raz, Majid

    2017-05-01

    Ultrasound-responsive nanodroplets are a class of new emerging smart drug delivery systems which provide image-guided nano-therapy of various diseases, especially cancers. Here, we developed multifunctional smart curcumin-loaded chitosan/perfluorohexane nanodroplets for contrast-ultrasound imaging and on-demand drug delivery. The nanodroplets were synthesized via nanoemulsion process. The optimal formulation with the size of 101.2nm and 77.8% curcumin entrapment was chosen for release study and cytotoxicity evaluation. Sonication at the frequency of 1MHz, 2W/cm 2 for 4min triggered the release of 63.5% of curcumin from optimal formulation (Cur-NDs-2). Ultrasound aided release study indicated that the concentration of perfluorohexane and the degree of acoustic droplet vaporization play important role in ultrasound-active drug release. B-mode ultrasound imaging confirmed strong ultrasound contrast of chitosan nanodroplets even at low concentrations via droplet to bubble transition. Finally, cytotoxicity of the ultrasound-responsive nanodroplets in the presence of ultrasound was evaluated in-vitro on 4T1 human breast cancer cells. Cell growth inhibitory effects of curcumin-loaded nanodroplets significantly increased by ultrasound exposure. According to the obtained results, these ultrasound responsive curcumin-loaded chitosan/perfluorohexane nanodroplets have a great potential for imaged-guided cancer therapy. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Ultrasound-guided intraarticular injection for MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Schaeffeler, Christoph; Bruegel, M.; Waldt, S.; Rummeny, E.J.; Woertler, K.

    2010-01-01

    Purpose: To evaluate ultrasound guidance for intraarticular contrast injection via an anterolateral approach in comparison with fluoroscopic guidance. Materials and Methods: Contrast agent injection was performed in 40 consecutive patients, 20 under sonographic guidance and 20 under fluoroscopic guidance. None of the patients had previous shoulder surgery. The procedure time was measured and the efficiency of joint distension, incidence of extravasation and intraarticular air on the consecutive MR arthrograms were assessed by three blinded radiologists with musculoskeletal radiology experience. Statistical analysis was performed using the Kruskal-Wallis test. Results: Intraarticular contrast injection was successfully accomplished in all 40 patients. Subsequent MR arthrograms did not show any significant difference between sonographic and fluoroscopic guidance with respect to diagnostic quality, joint distension (p = 0.6665), intraarticular air bubbles (p = 0.1567) and occurrence of contrast extravasation (p = 0.8565). The mean duration of ultrasound-guided injection was 7:30 min compared to a shorter procedure time of 4:15 min for fluoroscopic guidance. In both groups, no procedural complications were observed. Conclusion: Ultrasound-guided injection for MR arthrography of the shoulder via an anterolateral approach represents a simple, safe, and effective technique which yields comparable results to those of injection under fluoroscopic guidance, but is slightly more time-consuming. (orig.)

  9. Quality assurance in ultrasound screening for hepatocellular carcinoma using a standardized phantom and standard clinical images: a 3-year national investigation in Korea.

    Science.gov (United States)

    Choi, Joon-Il; Jung, Seung Eun; Kim, Pyo Nyun; Cha, Sang Hoon; Jun, Jae Kwan; Lee, Hoo-Yeon; Park, Eun-Cheol

    2014-06-01

    The purpose of this study was to investigate the quality of ultrasound (US) imaging for hepatocellular carcinoma screening. The investigation was performed at all medical institutes participating in the National Cancer Screening Program in Korea. For assessment of personnel, we inquired who was performing the US screenings. For phantom image evaluation, the dead zone, vertical and horizontal measurements, axial and lateral resolution, sensitivity, and gray scale/dynamic range were evaluated. For clinical image evaluation, US images of patients were evaluated in terms of the standard images, technical information, overall image quality, appropriateness of depth, foci, annotations, and the presence of any artifacts. Failure rates for phantom and clinical image evaluations at general hospitals, smaller hospitals, and private clinics were 20.9%, 24.5%, 24.1% and 5.5%, and 14.8% and 9.5%, respectively. No statistically significant difference was observed in the failure rates for the phantom images among groups of different years of manufacture. For the clinical image evaluation, the results of radiologists were significantly better than those of other professional groups (P = .0001 and .0004 versus nonradiology physicians and nonphysicians, respectively). The failure rate was also higher when the storage format was analog versus digital (P quality of the clinical images obtained by radiologists was the best. © 2014 by the American Institute of Ultrasound in Medicine.

  10. Assessment of a Low-Cost Ultrasound Pericardiocentesis Model

    Directory of Open Access Journals (Sweden)

    Marco Campo dell'Orto

    2013-01-01

    Full Text Available Introduction. The use of ultrasound during resuscitation is emphasized in the latest European resuscitation council guidelines of 2013 to identify treatable conditions such as pericardial tamponade. The recommended standard treatment of tamponade in various guidelines is pericardiocentesis. As ultrasound guidance lowers the complication rates and increases the patient’s safety, pericardiocentesis should be performed under ultrasound guidance. Acute care physicians actually need to train emergency pericardiocentesis. Methods. We describe in detail a pericardiocentesis ultrasound model, using materials at a cost of about 60 euros. During training courses of focused echocardiography n=67, participants tested the phantom and completed a 16-item questionnaire, assessing the model using a visual analogue scale (VAS. Results. Eleven of fourteen questions were answered with a mean VAS score higher than 60% and thus regarded as showing the strengths of the model. Unrealistically outer appearance and heart shape were rated as weakness of the model. A total mean VAS score of all questions of 63% showed that participants gained confidence for further interventions. Conclusions. Our low-cost pericardiocentesis model, which can be easily constructed, may serve as an effective training tool of ultrasound-guided pericardiocentesis for acute and critical care physicians.

  11. Assessment of a Low-Cost Ultrasound Pericardiocentesis Model

    Science.gov (United States)

    Campo dell'Orto, Marco; Hempel, Dorothea; Starzetz, Agnieszka; Seibel, Armin; Hannemann, Ulf; Walcher, Felix; Breitkreutz, Raoul

    2013-01-01

    Introduction. The use of ultrasound during resuscitation is emphasized in the latest European resuscitation council guidelines of 2013 to identify treatable conditions such as pericardial tamponade. The recommended standard treatment of tamponade in various guidelines is pericardiocentesis. As ultrasound guidance lowers the complication rates and increases the patient's safety, pericardiocentesis should be performed under ultrasound guidance. Acute care physicians actually need to train emergency pericardiocentesis. Methods. We describe in detail a pericardiocentesis ultrasound model, using materials at a cost of about 60 euros. During training courses of focused echocardiography n = 67, participants tested the phantom and completed a 16-item questionnaire, assessing the model using a visual analogue scale (VAS). Results. Eleven of fourteen questions were answered with a mean VAS score higher than 60% and thus regarded as showing the strengths of the model. Unrealistically outer appearance and heart shape were rated as weakness of the model. A total mean VAS score of all questions of 63% showed that participants gained confidence for further interventions. Conclusions. Our low-cost pericardiocentesis model, which can be easily constructed, may serve as an effective training tool of ultrasound-guided pericardiocentesis for acute and critical care physicians. PMID:24288616

  12. [An easy, safe and affective method for the treatment of intussusception: ultrasound-guided hydrostatic reduction].

    Science.gov (United States)

    Ülger, Fatma Esra Bahadır; Ülger, Aykut; Karakaya, Ali Erdal; Tüten, Fatih; Katı, Ömer; Çolak, Mustafa

    2014-03-01

    Intussusception is one of the important causes of intestinal obstruction in children. Hydrostatic reduction under ultrasound guidance is a popular treatment method for intussusception. In the present study, we aimed to explain the demographic characteristics of and treatment approaches in patients diagnosed with intussusception by ultrasound. Forty-one patients diagnosed with intussusception by ultrasound between August 2011 and May 2013 were retrospectively analyzed. Twenty-four of these patients who had no contraindications had been treated with ultrasound-guided hydrostatic reduction. Twenty-four of the patients were male and 17 were female, a 1.4/1 male-to-female ratio. The majority of the patients were between the ages of 6-24 months and 2-5 years. The mean age was 31.12±26.32 months (range 3-125). Patients were more frequently diagnosed in April and May. Seventeen patients who had clinical contraindications enrolled directly for surgery. In 20 of the 24 patients who underwent ultrasound-guided hydrostatic reduction, reduction was achieved. Three experienced recurrence. In two of these patients, successful reduction was achieved with the second attempt. The remaining patient was enrolled for surgery. Hydrostatic reduction was performed 26 times on these 24 patients, and in 22, success was achieved (84.6%). No procedure-related complications occurred in the patients. Ultrasound-guided hydrostatic reduction, with its high success rates and lack of radiation risk, should be the first choice therapeutic approach for children diagnosed with intussusception.

  13. Efficacy evaluation of laparoscopy assisted ultrasound guided radiofrequency ablation in the treatment of hepatocellular carcinoma beneath the diaphragm

    Directory of Open Access Journals (Sweden)

    Song WANG

    2017-06-01

    Full Text Available Objective To explore the feasibility, safety and efficacy of laparoscopy assisted ultrasound guided radiofrequency ablation (RFA in the treatment of hepatocellular carcinoma (HCC beneath the diaphragm. Methods Twenty- three consecutive patients with solitary HCC beneath the diaphragm were treated by laparoscopy assisted ultrasound guided RFA in the Chinese PLA General Hospital from January 2013 to March 2016. We observed the perioperative complications and followed- up long-term effect. Results All the 23 patients successfully underwent laparoscopy assisted ultrasound guided radiofrequency ablation. No serious complications such as massive hemorrhage, biliary fistula and severe pleural effusion, hemopneumothorax occurred in the patients during perioperative period. CT examination 2-3 days after the operation revealed that the tumor was completely covered by the ablation area. Besides, the survival condition was satisfactory during follow-up period of 9-38 months. Conclusion Laparoscopy-assisted ultrasound-guided radiofrequency ablation is effective and safe for HCC beneath the diaphragm. DOI: 10.11855/j.issn.0577-7402.2017.05.16

  14. Actuator-Assisted Calibration of Freehand 3D Ultrasound System.

    Science.gov (United States)

    Koo, Terry K; Silvia, Nathaniel

    2018-01-01

    Freehand three-dimensional (3D) ultrasound has been used independently of other technologies to analyze complex geometries or registered with other imaging modalities to aid surgical and radiotherapy planning. A fundamental requirement for all freehand 3D ultrasound systems is probe calibration. The purpose of this study was to develop an actuator-assisted approach to facilitate freehand 3D ultrasound calibration using point-based phantoms. We modified the mathematical formulation of the calibration problem to eliminate the need of imaging the point targets at different viewing angles and developed an actuator-assisted approach/setup to facilitate quick and consistent collection of point targets spanning the entire image field of view. The actuator-assisted approach was applied to a commonly used cross wire phantom as well as two custom-made point-based phantoms (original and modified), each containing 7 collinear point targets, and compared the results with the traditional freehand cross wire phantom calibration in terms of calibration reproducibility, point reconstruction precision, point reconstruction accuracy, distance reconstruction accuracy, and data acquisition time. Results demonstrated that the actuator-assisted single cross wire phantom calibration significantly improved the calibration reproducibility and offered similar point reconstruction precision, point reconstruction accuracy, distance reconstruction accuracy, and data acquisition time with respect to the freehand cross wire phantom calibration. On the other hand, the actuator-assisted modified "collinear point target" phantom calibration offered similar precision and accuracy when compared to the freehand cross wire phantom calibration, but it reduced the data acquisition time by 57%. It appears that both actuator-assisted cross wire phantom and modified collinear point target phantom calibration approaches are viable options for freehand 3D ultrasound calibration.

  15. Varying ultrasound power level to distinguish surgical instruments and tissue.

    Science.gov (United States)

    Ren, Hongliang; Anuraj, Banani; Dupont, Pierre E

    2018-03-01

    We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of varying transducer power level images. The proposed framework exploits the physics of ultrasound imaging system by varying the transducer power level to effectively distinguish metallic surgical instruments from tissue. This power-varying image-guidance is motivated from our observations that ultrasound imaging at different power levels exhibit different contrast enhancement capabilities between tissue and instruments in ultrasound-guided robotic beating-heart surgery. Using lower transducer power levels (ranging from 40 to 75% of the rated lowest ultrasound power levels of the two tested ultrasound scanners) can effectively suppress the strong imaging artifacts from metallic instruments and thus, can be utilized together with the images from normal transducer power levels to enhance the separability between instrument and tissue, improving intraoperative instrument tracking accuracy from the acquired noisy ultrasound volumetric images. We performed experiments in phantoms and ex vivo hearts in water tank environments. The proposed multi-level power-varying ultrasound imaging approach can identify robotic instruments of high acoustic impedance from low-signal-to-noise-ratio ultrasound images by power adjustments.

  16. [Efficacy and safety of ultrasound-guided or neurostimulator-guided bilateral axillary brachial plexus block].

    Science.gov (United States)

    Xu, C S; Zhao, X L; Zhou, H B; Qu, Z J; Yang, Q G; Wang, H J; Wang, G

    2017-10-17

    Objective: To explore the efficacy and safety of bilateral axillary brachial plexus block under the guidance of ultrasound or neurostimulator. Methods: From February 2012 to April 2014, 120 patients undergoing bilateral hand/forearm surgery in Beijing Jishuitan Hospital were enrolled and anaesthetized with bilateral axillary brachial plexus block. All patients were divided into two groups randomly using random number table: the ultrasound-guided group (group U, n =60) and the neurostimulator-guidedgroup (group N, n =60). The block was performed with 0.5% ropivacaine. Patients' age, sex and operation duration were recorded. Moreover, success rate, performance time, onset of sensor and motor block, performance pain, patient satisfaction degree and the incidence of related complications were also documented. Venous samples were collected at selected time points and the total and the plasma concentrations of ropivacaine were analyzed with HPLC. Results: The performance time, the onset of sensor block and the onset of motor block of group U were (8.2±1.5), (14.2± 2.2)and (24.0±3.5)min respectively, which were markedly shorter than those in group N( (14.6±3.9), (19.9±3.8), (28.8±4.2)min, respectively), and the differences were statistically significant( t =11.74, 10.09, 6.73, respectively, all P 0.05). No analgesic was superadded and no other anesthesia methods were applied. No complications were detected perioperatively. Conclusions: The bilateral axillary brachial plexus block under the guidance of ultrasound or neurostimulator are both effective and safe for bilateral hand/forearm surgery. However, the ultrasound-guided block may be more clinically beneficial because of its shorter performance time, rapid onset and higher patient satisfaction degree.

  17. Trans-Stent B-Mode Ultrasound and Passive Cavitation Imaging.

    Science.gov (United States)

    Haworth, Kevin J; Raymond, Jason L; Radhakrishnan, Kirthi; Moody, Melanie R; Huang, Shao-Ling; Peng, Tao; Shekhar, Himanshu; Klegerman, Melvin E; Kim, Hyunggun; McPherson, David D; Holland, Christy K

    2016-02-01

    Angioplasty and stenting of a stenosed artery enable acute restoration of blood flow. However, restenosis or a lack of re-endothelization can subsequently occur depending on the stent type. Cavitation-mediated drug delivery is a potential therapy for these conditions, but requires that particular types of cavitation be induced by ultrasound insonation. Because of the heterogeneity of tissue and stochastic nature of cavitation, feedback mechanisms are needed to determine whether the sustained bubble activity is induced. The objective of this study was to determine the feasibility of passive cavitation imaging through a metal stent in a flow phantom and an animal model. In this study, an endovascular stent was deployed in a flow phantom and in porcine femoral arteries. Fluorophore-labeled echogenic liposomes, a theragnostic ultrasound contrast agent, were injected proximal to the stent. Cavitation images were obtained by passively recording and beamforming the acoustic emissions from echogenic liposomes insonified with a low-frequency (500 kHz) transducer. In vitro experiments revealed that the signal-to-noise ratio for detecting stable cavitation activity through the stent was greater than 8 dB. The stent did not significantly reduce the signal-to-noise ratio. Trans-stent cavitation activity was also detected in vivo via passive cavitation imaging when echogenic liposomes were insonified by the 500-kHz transducer. When stable cavitation was detected, delivery of the fluorophore into the arterial wall was observed. Increased echogenicity within the stent was also observed when echogenic liposomes were administered. Thus, both B-mode ultrasound imaging and cavitation imaging are feasible in the presence of an endovascular stent in vivo. Demonstration of this capability supports future studies to monitor restenosis with contrast-enhanced ultrasound and pursue image-guided ultrasound-mediated drug delivery to inhibit restenosis. Copyright © 2016 World Federation for

  18. Ultrasound guided percutaneous fine needle aspiration biopsy of the liver with focal lesion

    International Nuclear Information System (INIS)

    Ko, Gang Seok; Yang, Hyun Cheol; Park, Byoung Lan; Kim, Byoung Geun; Sohn, Jang Sihn

    1985-01-01

    The ultrasound-guided fine needle aspirations were performed in order to diagnose a suspected neoplastic or infectious disease in 52 patients with focal liver disease. Of these, neoplastic lesions were suspected in 31 patients and infectious lesions in 21 patients ultrasonically and/or clinically. The overall accuracy for both suspected malignant and infectious disease was 79% (41/52). The primary indication for fine needle aspiration was to document the presence of malignancy and to avoid a diagnostic laparotomy, and to drain hepatic abscess. Consequently we were convinced that the ultrasound-guided percutaneous fine needle aspiration biopsy in the focal liver disease is the best method for a conclusive diagnosis

  19. Two-step reconstruction method using global optimization and conjugate gradient for ultrasound-guided diffuse optical tomography.

    Science.gov (United States)

    Tavakoli, Behnoosh; Zhu, Quing

    2013-01-01

    Ultrasound-guided diffuse optical tomography (DOT) is a promising method for characterizing malignant and benign lesions in the female breast. We introduce a new two-step algorithm for DOT inversion in which the optical parameters are estimated with the global optimization method, genetic algorithm. The estimation result is applied as an initial guess to the conjugate gradient (CG) optimization method to obtain the absorption and scattering distributions simultaneously. Simulations and phantom experiments have shown that the maximum absorption and reduced scattering coefficients are reconstructed with less than 10% and 25% errors, respectively. This is in contrast with the CG method alone, which generates about 20% error for the absorption coefficient and does not accurately recover the scattering distribution. A new measure of scattering contrast has been introduced to characterize benign and malignant breast lesions. The results of 16 clinical cases reconstructed with the two-step method demonstrates that, on average, the absorption coefficient and scattering contrast of malignant lesions are about 1.8 and 3.32 times higher than the benign cases, respectively.

  20. Treatment of cervical pregnancy with ultrasound-guided local methotrexate injection.

    Science.gov (United States)

    Yamaguchi, M; Honda, R; Erdenebaatar, C; Monsur, M; Honda, T; Sakaguchi, I; Okamura, Y; Ohba, T; Katabuchi, H

    2017-12-01

    Cervical pregnancy (CP) is a rare type of ectopic pregnancy. While methotrexate (MTX) is generally the first-line method of choice for clinically stable women, there is still no consensus on the most appropriate treatment for this abnormal pregnancy. The aim of this study was to investigate the efficacy of a single local MTX injection under transvaginal ultrasound guidance for the initial treatment of CP and to assess post-treatment fertility. We reviewed retrospectively 15 patients with CP treated with local MTX injection under transvaginal ultrasound guidance. In all patients, the serum human chorionic gonadotropin (hCG) levels were monitored and the gestational sac was evaluated using ultrasonography after treatment. Magnetic resonance imaging (MRI) was performed as necessary. We evaluated the patients' clinical characteristics and clinical course after treatment, the efficacy of the treatment and the post-treatment fertility in patients desiring subsequent pregnancy. The median estimated gestational age at the time of MTX injection was 6 + 2 (range, 5 + 2 to 11 + 0) weeks. All 15 patients were treated successfully, without the need for blood transfusion or surgical procedures; however, three patients required an additional local MTX injection due to a poor decline in serum hCG level following the initial injection, while one patient required uterine artery embolization due to persistent vaginal bleeding and an enlarging gestational sac with blood vessels visible on contrast-enhanced MRI. The mean time following initial MTX injection for hCG normalization was 43.8 (95% CI, 33.3-54.3) days and for resumption of menses was 68.4 (95% CI, 51.9-84.9) days. Seven of the 10 women desiring subsequent pregnancy following treatment had uneventful pregnancy, one became pregnant but miscarried spontaneously at 8 weeks of gestation, one was treated by laparoscopic surgery after diagnosis of a tubal pregnancy and one did not conceive. A single, ultrasound-guided

  1. Subacute posteromedial impingement of the ankle in athletes: MR imaging evaluation and ultrasound guided therapy

    International Nuclear Information System (INIS)

    Messiou, Christina; Robinson, Philip; O'Connor, Philip J.; Grainger, Andrew

    2006-01-01

    To describe the use of MR imaging and efficacy of ultrasound-guided steroid injection in the diagnosis and management of athletes with clinical posteromedial impingement of the ankle. A retrospective analysis of imaging findings on MR was undertaken in nine elite athletes with clinical posteromedial ankle impingement. MR studies from six professional athletes with posterolateral pain were also reviewed as an imaging control group. The two reviewing radiologists were blinded to the clinical details and the proportion of control and study subjects. The nine study athletes also underwent diagnostic ultrasound and ultrasound-guided injection of steroid and anaesthetic into the posteromedial capsular abnormality. Follow-up was by telephone interview. Posteromedial capsular thickening was seen only in athletes with posteromedial impingement (7/9). Posteromedial synovitis was present in all athletes with posteromedial impingement; however, posterior and posterolateral synovitis was also seen in these athletes. Mild posteromedial synovitis was present in two control athletes. Ultrasound identified abnormal posteromedial soft tissue thickening deep to tibialis posterior between the medial malleolus and talus in all nine athletes. After injection all athletes returned to their previous level of sport, with eight of the nine not experiencing any residual or recurrent symptoms. If MR imaging excludes significant coexistent abnormality, ultrasound can localise posteromedial soft tissue abnormality and guide injection therapy, allowing return to athletic activity without surgical intervention. (orig.)

  2. Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy

    Science.gov (United States)

    2018-01-01

    Ultrasound (US)-guided breast biopsy has become the main method for diagnosing breast pathology, and it has a high diagnostic accuracy, approaching that of open surgical biopsy. However, methods for confirming adequate lesion retrieval after US-guided biopsy are relatively limited and false-negative results are unavoidable. Determining imaging-pathology concordance after US-guided biopsy is essential for validating the biopsy result and providing appropriate management. In this review article, we briefly present the results of US-guided breast biopsy; describe general aspects to consider when establishing imaging-pathology concordance; and review the various categories of imaging-pathology correlations and corresponding management strategies. PMID:29169231

  3. Guided interventions in musculoskeletal ultrasound: what's the evidence?

    International Nuclear Information System (INIS)

    Davidson, J.; Jayaraman, S.

    2011-01-01

    Increasing histological and radiological understanding of the processes involved in soft-tissue injury is leading to novel targeted treatments. A number of reviews have recommended that these treatments should be performed with image guidance. This review describes current ultrasound-guided interventions and injections, together with the level of evidence for these. Discussion of guided interventions will include; percutaneous lavage (barbotage), brisement, dry needling, electrocoagulation, and of guided injections; corticosteroids, autologous substances (blood and platelet rich plasma), sclerosants, and prolotherapy (hyperosmolar dextrose). Representative imaging illustrating some of these techniques is included for correlation with the methods described. As these procedures are often performed in sportspeople, it is essential that the radiologist is aware of prohibited substances and methods outlined in an annual publication from the World Anti-Doping Association (WADA). Finally, future directions, including the use of autologous substances, mesenchymal and stem cells will be discussed.

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: ...

  5. Guiding tissue regeneration with ultrasound in vitro and in vivo

    Science.gov (United States)

    Dalecki, Diane; Comeau, Eric S.; Raeman, Carol H.; Child, Sally Z.; Hobbs, Laura; Hocking, Denise C.

    2015-05-01

    Developing new technologies that enable the repair or replacement of injured or diseased tissues is a major focus of regenerative medicine. This paper will discuss three ultrasound technologies under development in our laboratories to guide tissue regeneration both in vitro and in vivo. A critical obstacle in tissue engineering is the need for rapid and effective tissue vascularization strategies. To address this challenge, we are developing acoustic patterning techniques for microvascular tissue engineering. Acoustic radiation forces associated with ultrasound standing wave fields provide a rapid, non-invasive approach to spatially pattern cells in three dimensions without affecting cell viability. Acoustic patterning of endothelial cells leads to the rapid formation of microvascular networks throughout the volumes of three-dimensional hydrogels, and the morphology of the resultant microvessel networks can be controlled by design of the ultrasound field. A second technology under development uses ultrasound to noninvasively control the microstructure of collagen fibers within engineered tissues. The microstructure of extracellular matrix proteins provides signals that direct cell functions critical to tissue regeneration. Thus, controlling collagen microfiber structure with ultrasound provides a noninvasive approach to regulate the mechanical properties of biomaterials and control cellular responses. The third technology employs therapeutic ultrasound to enhance the healing of chronic wounds. Recent studies demonstrate increased granulation tissue thickness and collagen deposition in murine dermal wounds exposed to pulsed ultrasound. In summary, ultrasound technologies offer noninvasive approaches to control cell behaviors and extracellular matrix organization and thus hold great promise to advance tissue regeneration in vitro and in vivo.

  6. The design and fabrication of two portal vein flow phantoms by different methods

    Energy Technology Data Exchange (ETDEWEB)

    Yunker, Bryan E., E-mail: bryan.yunker@ucdenver.edu; Lanning, Craig J.; Shandas, Robin; Hunter, Kendall S. [Department of Bioengineering, University of Colorado – Denver/Anschutz, 12700 East 19th Avenue, MS 8607, Aurora, Colorado 80045 (United States); Dodd, Gerald D., E-mail: gerald.dodd@ucdenver.edu; Chang, Samuel; Scherzinger, Ann L. [Department of Radiology, University of Colorado – SOM, 12401 East 17th Avenue, Mail Stop L954, Aurora, Colorado 80045 (United States); Chen, S. James, E-mail: james.chen@ucdenver.edu [Department of Medicine, University of Colorado Denver, Colorado 80045 and Department of Medicine/Cardiology, University of Colorado – SOM, 12401 East 17th Avenue, Mail Stop B132, Aurora, Colorado 80045 (United States); Feng, Yusheng, E-mail: yusheng.feng@utsa.edu [Department of Mechanical Engineering, University of Texas – San Antonio, One UTSA Circle, Mail Stop: AET 2.332, San Antonio, Texas 78249–0670 (United States)

    2014-02-15

    Purpose: This study outlines the design and fabrication techniques for two portal vein flow phantoms. Methods: A materials study was performed as a precursor to this phantom fabrication effort and the desired material properties are restated for continuity. A three-dimensional portal vein pattern was created from the Visual Human database. The portal vein pattern was used to fabricate two flow phantoms by different methods with identical interior surface geometry using computer aided design software tools and rapid prototyping techniques. One portal flow phantom was fabricated within a solid block of clear silicone for use on a table with Ultrasound or within medical imaging systems such as MRI, CT, PET, or SPECT. The other portal flow phantom was fabricated as a thin walled tubular latex structure for use in water tanks with Ultrasound imaging. Both phantoms were evaluated for usability and durability. Results: Both phantoms were fabricated successfully and passed durability criteria for flow testing in the next project phase. Conclusions: The fabrication methods and materials employed for the study yielded durable portal vein phantoms.

  7. Ultrasound-guided facet block to low back pain: a case report

    Directory of Open Access Journals (Sweden)

    Ana Ellen Q. Santiago

    2014-07-01

    Full Text Available BACKGROUND: Osteoarthrosis is a common cause of low back pain. The diagnosis is clinical and can be confirmed by imaging studies. Pain treatment and confirmation of diagnosis are made by intra-articular injection of corticosteroid and by local anesthetic use, due to clinical improvement. A direct monitoring of the procedure can be done under fluoroscopy, a classic technique, or else by an ultrasound-guided procedure. CASE REPORT: Female patient, 88 years old, 1.68 m and 72 kg, with facet osteoarthrosis at L2-L3, L3-L4 and L4-L5 for two years. On physical examination, she exhibited pain on lateralization and spinal extension. We opted in favor of an ultrasound-guided facet joint block. A midline spinal longitudinal scan was obtained, with identification of the desired joint space at L3-L4. A 25 G needle was inserted into the skin by the echographic off-plane ultrasound technique. 1 mL of contrast was administered, with confirmation by fluoroscopy. After aspiration of the contrast, 1 mL of solution containing 0.25% bupivacaine hydrochloride and 10 mg of methylprednisolone acetate was injected. Injections into L3-L4, L2-L3 and L1-L2 to the right were applied. CONCLUSIONS: The visualization of the facet joint by ultrasound involves minimal risk, besides reduction of radiation. This option is suitable for a large part of the population. However, fluoroscopy and computed tomography remain as monitoring techniques indicated for patients with specific characteristics, such as obesity, severe degenerative diseases and anatomical malformations, in which the ultrasound technique is still in need of further study.

  8. T1-weighted MRI as a substitute to CT for refocusing planning in MR-guided focused ultrasound

    International Nuclear Information System (INIS)

    Wintermark, Max; Sumer, Suna; Lau, Benison; Cupino, Alan; Tustison, Nicholas J; Demartini, Nicholas; Elias, William J; Kassell, Neal; Patrie, James T; Xin, Wenjun; Eames, Matt; Snell, John; Hananel, Arik; Aubry, Jean-Francois

    2014-01-01

    Precise focusing is essential for transcranial MRI-guided focused ultrasound (TcMRgFUS) to minimize collateral damage to non-diseased tissues and to achieve temperatures capable of inducing coagulative necrosis at acceptable power deposition levels. CT is usually used for this refocusing but requires a separate study (CT) ahead of the TcMRgFUS procedure. The goal of this study was to determine whether MRI using an appropriate sequence would be a viable alternative to CT for planning ultrasound refocusing in TcMRgFUS. We tested three MRI pulse sequences (3D T1 weighted 3D volume interpolated breath hold examination (VIBE), proton density weighted 3D sampling perfection with applications optimized contrasts using different flip angle evolution and 3D true fast imaging with steady state precision T2-weighted imaging) on patients who have already had a CT scan performed. We made detailed measurements of the calvarial structure based on the MRI data and compared those so-called ‘virtual CT’ to detailed measurements of the calvarial structure based on the CT data, used as a reference standard. We then loaded both standard and virtual CT in a TcMRgFUS device and compared the calculated phase correction values, as well as the temperature elevation in a phantom. A series of Bland–Altman measurement agreement analyses showed T1 3D VIBE as the optimal MRI sequence, with respect to minimizing the measurement discrepancy between the MRI derived total skull thickness measurement and the CT derived total skull thickness measurement (mean measurement discrepancy: 0.025; 95% CL (−0.22–0.27); p = 0.825). The T1-weighted sequence was also optimal in estimating skull CT density and skull layer thickness. The mean difference between the phase shifts calculated with the standard CT and the virtual CT reconstructed from the T1 dataset was 0.08 ± 1.2 rad on patients and 0.1 ± 0.9 rad on phantom. Compared to the real CT, the MR-based correction showed a 1 °C drop on the

  9. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients.

    Science.gov (United States)

    Liu, Yu-Jiang; Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-09-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients' clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications.

  10. Safety of Ultrasound-Guided Botulinum Toxin Injections for Sialorrhea as Performed by Pediatric Otolaryngologists.

    Science.gov (United States)

    Shariat-Madar, Bahbak; Chun, Robert H; Sulman, Cecille G; Conley, Stephen F

    2016-05-01

    To evaluate incidence of complications and hospital readmission as a result of ultrasound-guided botulinum toxin injections to manage sialorrhea. Case series with chart review. Children's Hospital of Wisconsin. A case series with chart review was performed of all cases of ultrasound-guided injection of botulinum toxin by pediatric otolaryngologists from March 5, 2010, to September 26, 2014,. Primary outcomes included complications such as dysphagia, aspiration pneumonia, and motor paralysis. Secondary outcomes included hospitalization, intubation, and nasogastric tube placement. There were 48 patients, 111 interventions, and 306 intraglandular injections identified. Botulinum toxin type A and type B were utilized in 4 and 107 operative interventions, respectively. Type A was injected into 4 parotid and 4 submandibular glands, utilizing doses of 20 U per parotid and 30 U per submandibular gland. Type B was injected into 98 parotid and 200 submandibular glands, with average dosing of 923 U per parotid and 1170 U per submandibular gland, respectively. There were 2 instances of subjectively worsening of baseline dysphagia that self-resolved. No cases were complicated by aspiration pneumonia or motor paralysis. No patients required hospital readmission, intubation, or nasogastric tube placement. Prior published data indicated 16% complication incidence with ultrasound-guided injection of botulinum toxin. Our study found a low complication rate (0.6%) with ultrasound-guided injections of botulinum toxin to manage sialorrhea, without cases of aspiration pneumonia or motor paralysis. Of 306 intraglandular injections, there were 2 cases of worsening baseline subjective dysphagia that self-resolved. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  11. Safety and Efficacy of Ultrasound-Guided Fiducial Marker Implantation for CyberKnife Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Hyun; Hong, Seong; Sook; Kim, Jung Hoon; Park, Hyun Jeong; Chang, Yun Woo; Chang, A Ram [Soonchunhyang University Seoul Hospital, Seoul (Korea, Republic of); Kwon, Seok Beom [Hallym University College of Medicine, Chuncheon (Korea, Republic of)

    2012-06-15

    To evaluate the safety and technical success rate of an ultrasound-guided fiducial marker implantation in preparation for CyberKnife radiation therapy. We retrospectively reviewed 270 percutaneous ultrasound-guided fiducial marker implantations in 77 patients, which were performed from June 2008 through March 2011. Of 270 implantations, 104 were implanted in metastatic lymph nodes, 96 were in the liver, 39 were in the pancreas, and 31 were in the prostate. During and after the implantation, major and minor procedure-related complications were documented. We defined technical success as the implantation enabling adequate treatment planning and CT simulation. The major and minor complication rates were 1% and 21%, respectively. One patient who had an implantation in the liver suffered severe abdominal pain, biloma, and pleural effusion, which were considered as major complication. Abdominal pain was the most common complication in 11 patients (14%). Among nine patients who had markers inserted in the prostate, one had transient hematuria for less than 24 hours, and the other experienced transient voiding difficulty. Of the 270 implantations, 261 were successful (97%). The reasons for unsuccessful implantations included migration of fiducial markers (five implantations, 2%) and failure to discriminate the fiducial markers (three implantations, 1%). Among the unsuccessful implantation cases, six patients required additional procedures (8%). The symptomatic complications following ultrasound-guided percutaneous implantation of fiducial markers are relatively low. However, careful consideration of the relatively higher rate of migration and discrimination failure is needed when performing ultrasound-guided percutaneous implantations of fiducial markers.

  12. Study on in-vessel ISI for JOYO. Ultrasound propagation characteristic in the core support plate

    International Nuclear Information System (INIS)

    Ariyoshi, Masahiko; Ara, Kuniaki; Hirabayashi, Masaru

    2005-03-01

    The report describes the feasibility study on the in-vessel inspection technique to be applied for the experimental fast reactor JOYO. The object of this examination is to confirm the integration of reactor structure under sodium environment by an immediate means. The core support plate which is an important structure supports the weight of the core assembly is selected to an object of the inspection. In the examination until last year, the core support plate inspection equipment concept which combined ultrasound sensor with manipulator was constructed. In this concept, the ultrasound sensor is accessed to a low-pressure plenum sidewall and integrity of the core support plate weld is inspected. In this study, the ultrasound propagation behavior was examined to confirm the range where the core support plate by this concept was able to be inspected. The outline result is shown follows. (1) Only the transverse wave can be generated in the structure material by reflecting the incidence longitudinal wave from the sensor in the wedge. The use of this transverse wave is effective in the core support plate inspection. (2) Because the attenuation of the ultrasound wave depends on the distance, the sensor is made to approach from the fuel rack in the reactor vessel about two places in the upper part of the core support plate weld far from low-pressure plenum. (3) It is necessary to evaluate the permeability of the ultrasound wave by the mock-up examination in consideration of a peculiar attenuation of the structural material, the reflectivity from defect, etc. (4) In the core support plate inspection of phenix reactor, a weld about 4m away from the sensor position is inspected by using the Lamb wave. In this inspection, because it was generated to echo according to the geometrical shape of the structure material, the evaluation method by the analysis to identify the echo from the defect was constructed, and it was verified by the mock-up examination. It is preferable that

  13. Ultrasound-guided biopsy of transplanted pancreas: evaluation of 20 cases

    Directory of Open Access Journals (Sweden)

    Marcel Vieira da Nóbrega

    2009-03-01

    Full Text Available Objective: To report the experience with percutaneous biopsies of pancreatic grafts guided by ultrasonography. Methods: Series of cases referred from outpatient’s clinic for biopsy of pancreas transplant, between December 2006 and March 2008. Data were collected from medical electronic records for age, sex and histopathology. The indication for the procedure was obtained from medical and laboratory records. Doppler ultrasonography was performed for control and to guide biopsy in real time. Rresults: Twenty patients referred for biopsy of their transplanted pancreas over a one-year period were evaluated. In one patient, biopsy was not performed for having no safe access for ultrasound. It was used 18 gauge needles, mostly automatic-cut type. The main indications were increased blood glucose and pancreatic enzyme levels as well as reduction of urinary amylase. The sonographic aspect of the pancreatic graft was normal in 18 cases. In all 19 biopsies performed, satisfactory samples for histopathological study were obtained. There were no complications. Cconclusions: This series of cases demonstrated low sensitivity and specificity of ultrasound in diagnosis of pancreatic transplants disorders, but showed to be very useful to guide transplanted pancreas biopsies. Although no complications occurred in this experience, the risk-benefit relation should always be assessed for every patient.

  14. Ultrasound-Guided Multiple Peripheral Nerve Blocks in a Superobese Patient

    Directory of Open Access Journals (Sweden)

    Alper Kilicaslan

    2014-01-01

    Full Text Available The number of obese patients has increased dramatically worldwide. Morbid obesity is associated with an increased incidence of medical comorbidities and restricts the application choices in anesthesiology. We report a successfully performed combined ultrasound-guided blockade of the femoral, tibial, and common peroneal nerve in a superobese patient. We present a case report of a 31-year-old, ASA-PS II, super obese man (190 kg, 180 cm, BMI: 58 kg/m2 admitted to the emergency department with a type II segmental tibia shaft fracture and ankle dislocation after a vehicle accident. After two failed spinal anesthesia attempts, we decided to apply a femoral block combined with a sciatic block. Femoral blocks were successfully performed with US guided in-plane technique. Separate blocks of the tibial and common peroneal nerves were planned after the sciatic nerve could not be located due to the thick subcutaneous tissue. We performed a tibial nerve block at 2 cm above the popliteal crease and common peroneal nerve at the level of the fibular head with US guided in-plane technique. The blocks were successful and no block-related complications were noted. Ultrasound guidance allows new approaches for multiple peripheral nerve blocks with low local anesthetic doses in obese patients.

  15. A novel lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections

    DEFF Research Database (Denmark)

    Walter, Daisy; Will, Uwe; Sanchez-Yague, Andres

    2015-01-01

    BACKGROUND AND STUDY AIMS: A novel large-diameter, lumen-apposing, self-expanding metal stent with bilateral flanges was recently developed for endoscopic ultrasound (EUS)-guided transmural drainage of symptomatic pancreatic fluid collections (PFCs). The aim of this study was to evaluate the effi......BACKGROUND AND STUDY AIMS: A novel large-diameter, lumen-apposing, self-expanding metal stent with bilateral flanges was recently developed for endoscopic ultrasound (EUS)-guided transmural drainage of symptomatic pancreatic fluid collections (PFCs). The aim of this study was to evaluate...

  16. Feasibility of MRI-guided Focused Ultrasound as Organ-Sparing Treatment for Testicular Cancer

    Science.gov (United States)

    Staruch, Robert; Curiel, Laura; Chopra, Rajiv; Hynynen, Kullervo

    2009-04-01

    High cure rates for testicular cancer have prompted interest in organ-sparing surgery for patients with bilateral disease or single testis. Focused ultrasound (FUS) ablation could offer a noninvasive approach to organ-sparing surgery. The objective of this study was to determine the feasibility of using MR thermometry to guide organ-sparing focused ultrasound surgery in the testis. The testes of anesthetized rabbits were sonicated in several discrete locations using a single-element focused transducer operating at 2.787MHz. Focal heating was visualized with MR thermometry, using a measured PRF thermal coefficient of -0.0089±0.0003 ppm/° C. Sonications at 3.5-14 acoustic watts applied for 30 seconds produced maximum temperature elevations of 10-80° C, with coagulation verified by histology. Coagulation of precise volumes in the testicle is feasible with MRI-guided focused ultrasound. Variability in peak temperature for given sonication parameters suggests the need for online temperature feedback control.

  17. The role of ultrasound-guided triamcinolone injection in the treatment of de Quervain's disease: treatment and a diagnostic tool?

    NARCIS (Netherlands)

    Hajder, E.; de Jonge, M. C.; van der Horst, C. M. A. M.; Obdeijn, M. C.

    2013-01-01

    The purpose of this study was to describe the technique and usefulness of ultrasound-guided intrasheath injection of triamcinolone in the treatment of de Quervain's disease (dQD). Our study was retrospective in design. Seventy-one wrists of 62 patients who were treated with an ultrasound-guided

  18. Ultrasound-guided compression repair of pseudoaneurysms of brachial and femoral arteries - 2 cases-

    International Nuclear Information System (INIS)

    Kim, Hak Soo; Choi, Yeon Hyeon; Kim, Ji Eun; Lee, Sang Hoon; Kim, Myung A; Kim, Tae Kyoung; Cho, Jae Min

    1994-01-01

    Ultrasound-guided compression repair of postcatherization pseudoaneurysm has been reported recently. We successfuly treated two cases of cardiac catherization-related pseudoaneurysms of brachial and femoral arteries with compression repair technique under color Doppler US-guidance. We regard US-guided compression repair as a saft and effective first-line treatment for catherization-related pseudoaneurysm

  19. Towards Vision-Based Control of a Handheld Micromanipulator for Retinal Cannulation in an Eyeball Phantom

    Science.gov (United States)

    Becker, Brian C.; Yang, Sungwook; MacLachlan, Robert A.; Riviere, Cameron N.

    2012-01-01

    Injecting clot-busting drugs such as t-PA into tiny vessels thinner than a human hair in the eye is a challenging procedure, especially since the vessels lie directly on top of the delicate and easily damaged retina. Various robotic aids have been proposed with the goal of increasing safety by removing tremor and increasing precision with motion scaling. We have developed a fully handheld micromanipulator, Micron, that has demonstrated reduced tremor when cannulating porcine retinal veins in an “open sky” scenario. In this paper, we present work towards handheld robotic cannulation with the goal of vision-based virtual fixtures guiding the tip of the cannula to the vessel. Using a realistic eyeball phantom, we address sclerotomy constraints, eye movement, and non-planar retina. Preliminary results indicate a handheld micromanipulator aided by visual control is a promising solution to retinal vessel occlusion. PMID:24649479

  20. Ultrasound guided core biopsy of suspicious mammographic calcifications using high frequency and power Doppler ultrasound

    International Nuclear Information System (INIS)

    Teh, W.L.; Wilson, A.R.M; Evans, A.J.; Burrell, H.; Pinder, S.E.; Ellis, I.O.

    2000-01-01

    AIM: The pre-operative diagnosis of suspicious mammographic microcalcifications usually requires stereotactic needle biopsy. The aim of this study was to evaluate if high frequency 13 MHz ultrasound (HFUS) and power Doppler (PD) can aid visualization and biopsy of microcalcifications. MATERIALS AND METHODS: Forty-four consecutive patients presenting with microcalcifications without associated mammographic or palpable masses were examined with HFUS and PD. Ultrasound-guided core biopsy (USCB) was performed where possible. Stereotactic biopsy was carried out when US-guided biopsy was unsuccessful. Surgery was performed if a diagnosis of malignancy was made on core biopsy or if the repeat core biopsy was non-diagnostic. RESULTS: Forty-one patients (93%) had ultrasound abnormalities corresponding to mammographic calcification. USCB was performed on 37 patients. In 29/37, USCB obtained a definitive result (78.4%). USCB was non-diagnostic in 4/9 benign (44.4%) and 4/28 (14.3%) malignant lesions biopsied. The complete and absolute sensitivities for malignancy using USCB were 85.7% (24/28) and 81% (23/28), respectively. USCB correctly identified invasive disease in 12/23 (52.2%) cases. There was no significant difference in the presence of abnormal flow on PD between benign and malignant lesions. However, abnormal PD vascularity was present in 43.5% of invasive cancer and was useful in directing successful biopsy in eight cases. CONCLUSION: The combination of high frequency US with PD is useful in the detection and guidance of successful needle biopsy of microcalcifications particularly where there is an invasive focus within larger areas of DCIS. Teh, W.L. (2000)

  1. 3D conformal MRI-controlled transurethral ultrasound prostate therapy: validation of numerical simulations and demonstration in tissue-mimicking gel phantoms.

    Science.gov (United States)

    Burtnyk, Mathieu; N'Djin, William Apoutou; Kobelevskiy, Ilya; Bronskill, Michael; Chopra, Rajiv

    2010-11-21

    MRI-controlled transurethral ultrasound therapy uses a linear array of transducer elements and active temperature feedback to create volumes of thermal coagulation shaped to predefined prostate geometries in 3D. The specific aims of this work were to demonstrate the accuracy and repeatability of producing large volumes of thermal coagulation (>10 cc) that conform to 3D human prostate shapes in a tissue-mimicking gel phantom, and to evaluate quantitatively the accuracy with which numerical simulations predict these 3D heating volumes under carefully controlled conditions. Eleven conformal 3D experiments were performed in a tissue-mimicking phantom within a 1.5T MR imager to obtain non-invasive temperature measurements during heating. Temperature feedback was used to control the rotation rate and ultrasound power of transurethral devices with up to five 3.5 × 5 mm active transducer elements. Heating patterns shaped to human prostate geometries were generated using devices operating at 4.7 or 8.0 MHz with surface acoustic intensities of up to 10 W cm(-2). Simulations were informed by transducer surface velocity measurements acquired with a scanning laser vibrometer enabling improved calculations of the acoustic pressure distribution in a gel phantom. Temperature dynamics were determined according to a FDTD solution to Pennes' BHTE. The 3D heating patterns produced in vitro were shaped very accurately to the prostate target volumes, within the spatial resolution of the MRI thermometry images. The volume of the treatment difference falling outside ± 1 mm of the target boundary was, on average, 0.21 cc or 1.5% of the prostate volume. The numerical simulations predicted the extent and shape of the coagulation boundary produced in gel to within (mean ± stdev [min, max]): 0.5 ± 0.4 [-1.0, 2.1] and -0.05 ± 0.4 [-1.2, 1.4] mm for the treatments at 4.7 and 8.0 MHz, respectively. The temperatures across all MRI thermometry images were predicted within -0.3 ± 1.6 °C and 0

  2. Ultrashort echo-time MRI versus CT for skull aberration correction in MR-guided transcranial focused ultrasound: In vitro comparison on human calvaria.

    Science.gov (United States)

    Miller, G Wilson; Eames, Matthew; Snell, John; Aubry, Jean-François

    2015-05-01

    Transcranial magnetic resonance-guided focused ultrasound (TcMRgFUS) brain treatment systems compensate for skull-induced beam aberrations by adjusting the phase and amplitude of individual ultrasound transducer elements. These corrections are currently calculated based on a preacquired computed tomography (CT) scan of the patient's head. The purpose of the work presented here is to demonstrate the feasibility of using ultrashort echo-time magnetic resonance imaging (UTE MRI) instead of CT to calculate and apply aberration corrections on a clinical TcMRgFUS system. Phantom experiments were performed in three ex-vivo human skulls filled with tissue-mimicking hydrogel. Each skull phantom was imaged with both CT and UTE MRI. The MR images were then segmented into "skull" and "not-skull" pixels using a computationally efficient, threshold-based algorithm, and the resulting 3D binary skull map was converted into a series of 2D virtual CT images. Each skull was mounted in the head transducer of a clinical TcMRgFUS system (ExAblate Neuro, Insightec, Israel), and transcranial sonications were performed using a power setting of approximately 750 acoustic watts at several different target locations within the electronic steering range of the transducer. Each target location was sonicated three times: once using aberration corrections calculated from the actual CT scan, once using corrections calculated from the MRI-derived virtual CT scan, and once without applying any aberration correction. MR thermometry was performed in conjunction with each 10-s sonication, and the highest single-pixel temperature rise and surrounding-pixel mean were recorded for each sonication. The measured temperature rises were ∼ 45% larger for aberration-corrected sonications than for noncorrected sonications. This improvement was highly significant (p skull-induced ultrasound aberration corrections. Their results suggest that UTE MRI could be used instead of CT to implement such corrections on

  3. Computer phantoms for simulating ultrasound B-mode and CFM images

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Munk, Peter

    1997-01-01

    in a file that defines their position and amplitude. Adjusting the number of scatterers and their relative amplitude yields the proper image.Five different computer phantoms are described. The first one consists of a number of point targets. It is used for studying the point spread function as a function...... of spatial position, and can give an indication of sidelobe levels and focusing abilities. The second phantom contains a number of cysts and point tagets along with a homogeneous speckle pattern. This is used for investigating image contrast, and the system's ability to detect low-contrast objects. The third...... phantom is for realistic clinical imaging. It contains the image of a 12 week old fetus, where the placenta and the upper body of the fetus is visible. This phantom gives an indication of the whole system's capability for real imaging. The current fetus phantom is only two-dimensional, as it is constant...

  4. Simplified spinal cord phantom for evaluation of SQUID magnetospinography

    International Nuclear Information System (INIS)

    Adachi, Y; Oyama, D; Uehara, G; Somchai, N; Kawabata, S

    2014-01-01

    Spinal cord functional imaging by magnetospinography (MSG) is a noninvasive diagnostic method for spinal cord diseases. However, the accuracy and spatial resolution of lesion localization by MSG have barely been evaluated in detail so far. We developed a simplified spinal cord phantom for MSG evaluation. The spinal cord phantom is composed of a cylindrical vessel filled with saline water, which acts as a model of a neck. A set of modeled vertebrae is arranged in the cylindrical vessel, which has a neural current model made from catheter electrodes. The neural current model emulates the current distribution around the activated site along the axon of the spinal cord nerve. Our MSG system was used to observe the magnetic field from the phantom; a quadrupole-like pattern of the magnetic field distribution, which is a typical distribution pattern for spinal cord magnetic fields, was successfully reproduced by the phantom. Hence, the developed spinal cord phantom can be used to evaluate MSG source analysis methods.

  5. Ultrasound-guided Breast Biopsy in the Resource-limited Setting: An Initial Experience in Rural Uganda

    Directory of Open Access Journals (Sweden)

    Christopher R. Stark

    2017-06-01

    Full Text Available Purpose: To describe the methodology and initial experience behind creation of an ultrasoundguided percutaneous breast core biopsy program in rural Uganda. Methods and Materials: Imaging the World Africa (ITWA is the registered non-governmental organization division of Imaging the World (ITW, a not-for-profit organization whose primary aim is the integration of affordable high-quality ultrasound into rural health centers. In 2013, ITWA began the pilot phase of an IRB-approved breast care protocol at a rural health center in Uganda. As part of the protocol’s diagnostic arm, an ultrasound-guided percutaneous breast core biopsy training curriculum was implemented in tandem with creation of regionally supplied biopsy kits. Results: A surgeon at a rural regional referral hospital was successfully trained and certified to perform ultrasound-guided percutaneous breast core biopsies. Affordable and safe biopsy kits were created using locally available medical supplies with the cost of each kit totaling $10.62 USD. Conclusion: Successful implementation of an ultrasound-guided percutaneous breast core biopsy program in the resource-limited setting is possible and can be made sustainable through incorporation of local health care personnel and regionally supplied biopsy materials. Our hope is that ITWA’s initial experience in rural Uganda can serve as a model for similar programs in the future.

  6. The ultrasound-guided retrolaminar block: volume-dependent injectate distribution

    Directory of Open Access Journals (Sweden)

    Damjanovska M

    2018-02-01

    Full Text Available Marija Damjanovska,1 Tatjana Stopar Pintaric,1,2 Erika Cvetko,2 Kamen Vlassakov3 1Clinical Department of Anesthesiology and Intensive Therapy, University Medical Centre Ljubljana, Ljubljana, Slovenia; 2Institute of Anatomy, Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia; 3Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, USA Purpose: The ultrasound-guided retrolaminar block is one of the newer and simpler alternatives to the traditional, often technically challenging, paravertebral (PV block. Its feasibility, safety, and efficacy have already been clinically demonstrated in patients with multiple rib fractures using higher volumes of local anesthetic, when compared with the traditional approach. The primary aim of this observational anatomical study was to assess the spread of local anesthetic from the retrolaminar injection point to the PV space and its volume dependence. Second, we assessed the incidence of epidural and contralateral PV spread in the both groups.Methods: Ten fresh porcine cadavers were randomized into 2 groups (n=5 each to receive ultrasound-guided retrolaminar injections at Th4-Th5 level with either 10 mL (low-volume group or 30 mL (high-volume group of 2% lidocaine and methylene blue mixture. After the procedure, the cadavers were dissected and frozen. Cross-section cuts (~1 cm thick were performed to evaluate the injectate spread.Results: In the high-volume group, injectate spread from the retrolaminar to the PV space was observed in all specimens (5 out of 5; 100%, while in the low-volume group, no apparent spread to the PV space was found (0 out of 5; 0%. No epidural or contralateral PV spread was observed in any of the specimens.Conclusion: Following ultrasound-guided retrolaminar injections in fresh porcine cadavers, injectate spread from the retrolaminar tissue plane to the PV space is strongly volume dependent

  7. Ultrasound guided versus landmark guided corticosteroid injection in patients with rotator cuff syndrome: Randomised controlled trial.

    Science.gov (United States)

    Bhayana, Himanshu; Mishra, Puneet; Tandon, Anupama; Pankaj, Amite; Pandey, Rohit; Malhotra, Raskesh

    2018-03-01

    Impingement syndrome is the most common differential in a patient presenting to an orthopaedic OPD with shoulder pain. Impingement syndrome is often managed with subacromial corticosteroid injection, which can be instilled using either landmark guided (LMG) approach or with the assistance of ultrasound (US). This study was envisaged to enquire whether ultrasound assistance improves the accuracy, efficacy or safety profile of the injection. 60 patients of rotator cuff syndrome underwent diagnostic ultrasound. They were randomly assigned to receive subacromial injection of 2 ml (40 mg/ml) methylprenisolone and 2 ml of 1% lignocaine combination either by US assistance (n = 30) or using LMG assistance (n = 30). The patients were evaluated before injection and on follow up visits at day 5, week 3, week 6 and 3rd month by a single assessor. The assessor was blinded of the treatment group to which patient belonged. Clinical assessment included demographic and clinical data, accuracy of injection, VAS (0-100) for pain, Constant score with goniometer evaluation of range of motion, patient's self assessment proforma and post injection side effects if any. Initial demographic, clinical and US findings in the groups exhibited no significant differences. The accuracy of US guided injections (100%) was more when compared from LMG injection (93.3%). Both VAS and Constant score showed significant improvement following steroid injection up to 3 months of follow up. However the differences in the two groups were not significant suggesting comparable efficacy of the two approaches. (Mean VAS score decrease: 27.23 for US and 25.16 for LMG, p guided injections have a higher accuracy of drug placement in the subacromial bursa, there is no difference in terms of clinical outcomes or safety profile of either of the method. Hence US guided injections seems to be unjustified, when compared to equally efficacious and cost effective LMG steroid injection.

  8. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    Science.gov (United States)

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  9. MRI screening-detected breast lesions in high-risk young women: the value of targeted second-look ultrasound and imaging-guided biopsy.

    Science.gov (United States)

    Peter, P; Dhillon, R; Bose, S; Bourke, A

    2016-10-01

    To analyse the value of targeted second-look ultrasound and imaging-guided biopsy in high-risk young women eligible for screening magnetic resonance imaging (MRI) in a tertiary referral centre in Perth, Western Australia. A retrospective analysis of eligible high-risk young women who underwent screening breast MRI and targeted second-look ultrasound between June 2012 and June 2014 was performed with review of data. Over a 2-year period, 139 women underwent high-risk screening MRI. Of these, 30 women (with a total of 45 lesions) were recalled for targeted second-look ultrasound. Thirty-four MRI-detected lesions were identified on targeted ultrasound with 19 of them proceeding to ultrasound-guided biopsy, while the remaining 15 lesions were considered benign on ultrasound, were not biopsied, and were stable on follow-up imaging 12 months later. One lesion proceeded to an MRI-guided biopsy to confirm a benign result. Of the 11 lesions not seen on ultrasound, nine underwent MRI biopsy, one proceeded directly to hook wire localisation and excision, and one did not return for biopsy and was lost to follow-up. The overall biopsy rate was 14.4%. The cancer detection rate was 1.4%. The results of this study indicate that targeted second-look ultrasound and ultrasound-guided biopsy is a cost-effective and time-efficient approach for MRI-detected lesions in young women at high risk of developing breast cancer. MRI-guided biopsy should be considered for ultrasonographically occult suspicious lesions as there is a low, but definite, risk of cancer. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  10. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: A randomised controlled trial.

    Science.gov (United States)

    Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I

    2017-03-01

    Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or percentage of perfect

  11. The feasibility of trans-abdominal biopsy by ultrasound guiding during uterine artery embolization for benign diseases of uterus

    International Nuclear Information System (INIS)

    Guo Wenbo; Yang Jianyong; Chen Wei; Zhuang Wenquan; Li Heping; Yao Shuzhong

    2006-01-01

    Objective: To investigate the feasibility of trans-abdominal biopsy by ultrasound guiding during uterine artery embolization (UAE) for uterine fibroids and adenomyosis. Methods: Trans-abdominal biopsies by ultrasound guiding were performed in 62 cases of uterine fibroids or adenomyosis diagnosed pre-UAE. Multi-points in focus were punctured in single lesion and multi-points in every focus of multiple lesions were punctured. The diagnosis before UAE was made according to clinical symptoms, pelvic ultrasound and pelvic magnetic resonance imaging (MRI). The pathological diagnosis by biopsy was comparative to its clinical diagnosis before biopsy. The complications were also observed. Results: Biopsies were performed successfully in 60 cases with pathological examination, including 52 uterine fibroids and 8 adenomyosis cases. The clinical diagnosis of uterine fibroids or adenomyosis was coincident with the pathology except 2 cases of fibroids diagnosed before biopsy were failed to puncture. Conclusion: Trans-abdominal biopsy by ultrasound guiding in uterine artery embolization for benign diseases of uterus is safe and feasible. (authors)

  12. Glenohumeral joint injection: a comparative study of ultrasound and fluoroscopically guided techniques before MR arthrography.

    NARCIS (Netherlands)

    Rutten, M.J.; Collins, J.M.; Maresch, B.J.; Smeets, J.H.R.; Janssen, C.M.; Kiemeney, L.A.L.M.; Jager, G.J.

    2009-01-01

    To assess the variability in accuracy of contrast media introduction, leakage, required time and patient discomfort in four different centres, each using a different image-guided glenohumeral injection technique. Each centre included 25 consecutive patients. The ultrasound-guided anterior (USa) and

  13. Standard Guide for In-Service Annealing of Light-Water Moderated Nuclear Reactor Vessels

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This guide covers the general procedures to be considered for conducting an in-service thermal anneal of a light-water moderated nuclear reactor vessel and demonstrating the effectiveness of the procedure. The purpose of this in-service annealing (heat treatment) is to improve the mechanical properties, especially fracture toughness, of the reactor vessel materials previously degraded by neutron embrittlement. The improvement in mechanical properties generally is assessed using Charpy V-notch impact test results, or alternatively, fracture toughness test results or inferred toughness property changes from tensile, hardness, indentation, or other miniature specimen testing (1). 1.2 This guide is designed to accommodate the variable response of reactor-vessel materials in post-irradiation annealing at various temperatures and different time periods. Certain inherent limiting factors must be considered in developing an annealing procedure. These factors include system-design limitations; physical constrain...

  14. Superficial vessel reconstruction with a multiview camera system

    Science.gov (United States)

    Marreiros, Filipe M. M.; Rossitti, Sandro; Karlsson, Per M.; Wang, Chunliang; Gustafsson, Torbjörn; Carleberg, Per; Smedby, Örjan

    2016-01-01

    Abstract. We aim at reconstructing superficial vessels of the brain. Ultimately, they will serve to guide the deformation methods to compensate for the brain shift. A pipeline for three-dimensional (3-D) vessel reconstruction using three mono-complementary metal-oxide semiconductor cameras has been developed. Vessel centerlines are manually selected in the images. Using the properties of the Hessian matrix, the centerline points are assigned direction information. For correspondence matching, a combination of methods was used. The process starts with epipolar and spatial coherence constraints (geometrical constraints), followed by relaxation labeling and an iterative filtering where the 3-D points are compared to surfaces obtained using the thin-plate spline with decreasing relaxation parameter. Finally, the points are shifted to their local centroid position. Evaluation in virtual, phantom, and experimental images, including intraoperative data from patient experiments, shows that, with appropriate camera positions, the error estimates (root-mean square error and mean error) are ∼1  mm. PMID:26759814

  15. Effectiveness of ultrasound-guided injections combined with shoulder exercises in the treatment of subacromial adhesive bursitis.

    Science.gov (United States)

    Gasparre, Giuseppe; Fusaro, Isabella; Galletti, Stefano; Volini, Silvia; Benedetti, Maria Grazia

    2012-05-01

    The aim of this study was to evaluate whether the association of exercises for the shoulder with ultrasound-guided injection into the bursa significantly improves the treatment outcome in adhesive bursitis. Two groups of 35 patients, one treated with ultrasound-guided injection (UGI) and the other one with ultrasound-guided injection and home exercise program (UGI-exercise) for 1 month, were assessed for pain and shoulder function before treatment, 1 and 3 months post-treatment. Fourteen patients in UGI group and 23 patients in the UGI-exercises group were completely free of pain after 1 month (p = 0.031). At 3 months' follow-up, patients in the UGI-exercise group showed a significant improvement with respect to the other group (p = 0.005). No differences were found in function assessment. The UGI combined with shoulder exercises in the treatment of subacromial adhesive bursitis is effective to ensure a more frequent complete pain relief in the medium term.

  16. Steroid injection for painful shoulder: Usefulness of ultrasound-guided approach

    International Nuclear Information System (INIS)

    Lee, Min Hee

    2004-01-01

    To evaluate the efficacy of steroid injection into the subacromial bursa and biceps tendon sheath for painful shoulders and the usefulness of ultrasound-guided approach. Seventeen shoulders of twelve patients with shoulder pain and limited motion were included, and these patient were clinically diagnosed as a painful arc syndrome. Under ultrasound guidance, steroid injection was performed into the subacormial bursa (13 cases) and biceps tendon sheath (4 cases). In 7 cases, 1 mL of steroid was used while the remaining six patients received a mixture of 1 mL of steroid and 1 ml of lidocaine. Both shoulders of two patients received 0.5 mL of steroid. The location of needle and injection duration of fluid were continuously monitored, and complications such as leakage of steroid were recorded. Medical records were reviewed for the presence of pain relief and increasing range of motion following the injection. On ultrasonogram, the needle within the subacromial bursa and biceps tendon sheath was seen as a linear echogenic structure, and injected fluid was identified. There was neither the leakage of steroid injection nor any other complications. In 16 (94%) of 17 shoulders, there was decreased intensity of shoulder pain while increased range of motion was noted in three patients following the injection. Steroid injection into the subacormial bursa and biceps tendon sheath is effective in treating shoulder pain and limited range of motion of the shoulder, and ultrasound is useful guiding method.

  17. Optimizing MR imaging-guided navigation for focused ultrasound interventions in the brain

    Science.gov (United States)

    Werner, B.; Martin, E.; Bauer, R.; O'Gorman, R.

    2017-03-01

    MR imaging during transcranial MR imaging-guided Focused Ultrasound surgery (tcMRIgFUS) is challenging due to the complex ultrasound transducer setup and the water bolus used for acoustic coupling. Achievable image quality in the tcMRIgFUS setup using the standard body coil is significantly inferior to current neuroradiologic standards. As a consequence, MR image guidance for precise navigation in functional neurosurgical interventions using tcMRIgFUS is basically limited to the acquisition of MR coordinates of salient landmarks such as the anterior and posterior commissure for aligning a stereotactic atlas. Here, we show how improved MR image quality provided by a custom built MR coil and optimized MR imaging sequences can support imaging-guided navigation for functional tcMRIgFUS neurosurgery by visualizing anatomical landmarks that can be integrated into the navigation process to accommodate for patient specific anatomy.

  18. Open-source, small-animal magnetic resonance-guided focused ultrasound system.

    Science.gov (United States)

    Poorman, Megan E; Chaplin, Vandiver L; Wilkens, Ken; Dockery, Mary D; Giorgio, Todd D; Grissom, William A; Caskey, Charles F

    2016-01-01

    MR-guided focused ultrasound or high-intensity focused ultrasound (MRgFUS/MRgHIFU) is a non-invasive therapeutic modality with many potential applications in areas such as cancer therapy, drug delivery, and blood-brain barrier opening. However, the large financial costs involved in developing preclinical MRgFUS systems represent a barrier to research groups interested in developing new techniques and applications. We aim to mitigate these challenges by detailing a validated, open-source preclinical MRgFUS system capable of delivering thermal and mechanical FUS in a quantifiable and repeatable manner under real-time MRI guidance. A hardware and software package was developed that includes closed-loop feedback controlled thermometry code and CAD drawings for a therapy table designed for a preclinical MRI scanner. For thermal treatments, the modular software uses a proportional integral derivative controller to maintain a precise focal temperature rise in the target given input from MR phase images obtained concurrently. The software computes the required voltage output and transmits it to a FUS transducer that is embedded in the delivery table within the magnet bore. The delivery table holds the FUS transducer, a small animal and its monitoring equipment, and a transmit/receive RF coil. The transducer is coupled to the animal via a water bath and is translatable in two dimensions from outside the magnet. The transducer is driven by a waveform generator and amplifier controlled by real-time software in Matlab. MR acoustic radiation force imaging is also implemented to confirm the position of the focus for mechanical and thermal treatments. The system was validated in tissue-mimicking phantoms and in vivo during murine tumor hyperthermia treatments. Sonications were successfully controlled over a range of temperatures and thermal doses for up to 20 min with minimal temperature overshoot. MR thermometry was validated with an optical temperature probe, and focus

  19. Ultrasound-guided interstitial laser photocoagulation of an autonomous thyroid nodule

    DEFF Research Database (Denmark)

    Døssing, Helle; Bennedbaek, Finn Noe; Hegedüs, Laszlo

    2003-01-01

    effects and often necessitates multiple treatment sessions. We present a case of a 17-year-old female successfully treated with ultrasound (US)-guided percutaneous interstitial laser photocoagulation (ILP) for an AFTN. Initially, she had a serum thyrotropin (TSH) of 0.01 mU/L and normal peripheral thyroid.......9 mL (40% reduction) without further alterations during an additional 9 months of follow-up. Side effects were transient thyrotoxicosis and local pain as seen with PEI. To our knowledge, this is the first reported case of ILP used in a patient with a pretoxic thyroid nodule. US-guided thermic tissue...

  20. Ultrasound-guided brachial plexus block: a study on 30 patients

    Directory of Open Access Journals (Sweden)

    Amiri HR

    2009-05-01

    Full Text Available "n Normal 0 false false false EN-GB X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Successful brachial plexus blocks rely on proper techniques of nerve localization, needle placement, and local anesthetic injection. Standard approaches used today (elicitation of paresthesia or nerve-stimulated muscle contraction, unfortunately, are all "blind" techniques resulting in procedure-related pain and complications. Ultrasound guidance for brachial plexus blocks can potentially improve success and complication rates. This study presents the ultrasound-guided brachial plexus blocks for the first time in Iran in adults and pediatrics. "n"n Methods: In this study ultrasound-guided brachial plexus blocks in 30 patients (25 adults & 5 pediatrics scheduled for an elective upper extremity surgery, are introduced. Ultrasound imaging was used to identify the brachial plexus before the block, guide the block needle to reach target nerves, and visualize the pattern of local anesthetic spread. Needle position was further confirmed by nerve stimulation before injection. Besides basic variables, block approach, block time, postoperative analgesia duration (VAS<3 was considered as target pain control opioid consumption during surgery, patient satisfaction and block related complications were reported

  1. Neuroprotective effects of ultrasound-guided nerve growth factor injections after sciatic nerve injury

    Directory of Open Access Journals (Sweden)

    Hong-fei Li

    2015-01-01

    Full Text Available Nerve growth factor (NGF plays an important role in promoting neuroregeneration after peripheral nerve injury. However, its effects are limited by its short half-life; it is therefore important to identify an effective mode of administration. High-frequency ultrasound (HFU is increasingly used in the clinic for high-resolution visualization of tissues, and has been proposed as a method for identifying and evaluating peripheral nerve damage after injury. In addition, HFU is widely used for guiding needle placement when administering drugs to a specific site. We hypothesized that HFU guiding would optimize the neuroprotective effects of NGF on sciatic nerve injury in the rabbit. We performed behavioral, ultrasound, electrophysiological, histological, and immunohistochemical evaluation of HFU-guided NGF injections administered immediately after injury, or 14 days later, and compared this mode of administration with intramuscular NGF injections. Across all assessments, HFU-guided NGF injections gave consistently better outcomes than intramuscular NGF injections administered immediately or 14 days after injury, with immediate treatment also yielding better structural and functional results than when the treatment was delayed by 14 days. Our findings indicate that NGF should be administered as early as possible after peripheral nerve injury, and highlight the striking neuroprotective effects of HFU-guided NGF injections on peripheral nerve injury compared with intramuscular administration.

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... size, shape and consistency (whether the object is solid or filled with fluid). In medicine, ultrasound is ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ... structure and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound ...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, ...

  6. Noninvasive Label-Free Detection of Micrometastases in the Lymphatics with Ultrasound-Guided Photoacoustic Imaging

    Science.gov (United States)

    2015-10-01

    imaging can be used to guide dissection. We have also successfully integrated a programmable ultrasound machine ( Verasonics Vantage ) and tunable pulsed...Mobile HE) with the programmable ultrasound machine ( Verasonics Vantage ). We have synchronized the signals to enable interleaved acquisition of US...transducer (L11-4v, Verasonics Inc.) and build a housing which effectively couples fiber optic light delivery. o What opportunities for training and

  7. Contrast ultrasound-guided photothermal therapy using gold nanoshelled microcapsules in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shumin [Department of Ultrasonography, Peking University Third Hospital, Beijing 100083 (China); Ordos Center Hospital, Ordos, Inner Mongolia 017000 (China); Dai, Zhifei [Department of Biomedical Engineering, College of Engineering, Peking University, Beijing 100871 (China); Ke, Hengte [Nanomedicine and Biosensor Laboratory, School of Life Science and Technology, Harbin Institute of Technology, Harbin 150001 (China); Qu, Enze [Department of Ultrasonography, Peking University Third Hospital, Beijing 100083 (China); Qi, Xiaoxu; Zhang, Kuo [Department of Laboratory Animal Science, Peking University Health Science Center, Beijing 100019 (China); Wang, Jinrui, E-mail: jinrui_wang@sina.com [Department of Ultrasonography, Peking University Third Hospital, Beijing 100083 (China)

    2014-01-15

    Objectives: The purpose of this study was to test whether dual functional gold nano-shelled microcapsules (GNS-MCs) can be used as an ultrasound imaging enhancer and as an optical absorber for photothermal therapy (PTT) in a rodent model of breast cancer. Methods: GNS-MCs were fabricated with an inner air and outer gold nanoshell spherical structure. Photothermal cytotoxicity of GNS-MCs was tested with BT474 cancer cells in vitro and non-obese diabetes-SCID (NOD/SCID) mice with breast cancer. GNS-MCs were injected into the tumor under ultrasound guidance and treated with near-infrared (NIR) laser irradiation. The photothermal ablative effectiveness of GNS-MCs was evaluated by measuring the surface and internal temperature of the tumor as well as the size of the tumor using histological confirmation. Results: NIR laser irradiation resulted in significant tumor cell death in GNS-MCs-treated BT474 cells in vitro. GNS-MCs were able to serve as an ultrasound enhancer to guide the intratumoral injection of GNS-MCs and ensure their uniform distribution. In vivo studies revealed that NIR laser irradiation increased the intratumoral temperature to nearly 70 °C for 8 min in GNS-MCs-treated mice. Tumor volumes decreased gradually and tumors were completely ablated in 6 out of 7 mice treated with GNS-MCs and laser irradiation by 17 days after treatment. Conclusion: This study demonstrates that ultrasound-guided PTT with theranostic GNS-MCs is a promising technique for in situ treatment of breast cancer.

  8. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis

    Science.gov (United States)

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A.; Quiles, Katherine G.; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2017-01-01

    Background: The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. Methods and results: This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Conclusions: Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis. PMID:29265002

  9. Radiofrequency ablation guided by contrast-enhanced ultrasound for hepatic malignancies: Preliminary results

    International Nuclear Information System (INIS)

    Dong, Y.; Wang, W.-P.; Gan, Y.-H.; Huang, B.-J.; Ding, H.

    2014-01-01

    Aim: To evaluate whether contrast-enhanced ultrasound (CEUS)-guided radiofrequency ablation (RFA) can be performed effectively in small hepatic malignancies that are invisible or poorly visualized at traditional grey-scale ultrasonography (US). Materials and methods: The institutional ethics committee approved the study, and all patients provided written informed consent before their enrolment. The study focused on 55 patients (43 men, 12 women, age 57.4 ± 10.9 years) with 60 hepatic lesions from May 2010 to March 2011. All lesions were treated with multipolar radiofrequency ablation (RFA). During the RFA procedure, with the injection of ultrasound contrast agent (sulphur hexafluoride; SonoVue, Bracco Imaging Spa, Milan, Italy), RFA was conducted under CEUS guidance when the optimal depiction of a lesion was obtained. Artificial pleural effusions were used in those cases obstructed by the lungs. Twenty-four hours after RFA, contrast-enhanced MRI was used as the reference standard to evaluate the primary effectiveness rate and complete tumour necrosis. The follow-up time was 12–24 months (median 15 months). Results: Among 60 hepatic malignancies, CEUS detected 57 lesions (95%), which was higher than that at US (26.6%). Artificial pleural effusions were performed in three cases, resulting in the detection of three additional lesions. The insertion of RFA electrodes was monitored by CEUS in all lesions. Immediately after RFA, complete tumour necrosis were achieved in all 60 lesions as apparent at MRI, for a primary effectiveness rate of 100%. Conclusion: CEUS-guided RFA is a promising technique for targeting and improving the efficiency of treatment of hepatic malignancies. - Highlights: • CEUS guided RFA improved the detectability of hepatic malignancies indistinctive on gray-scale ultrasound. • Pre-operation CEUS helped localization of indistinctive hepatic malignancies. • CEUS guided RFA of hepatic malignancies achieved a more complete ablation

  10. Ultrasound-guided peripheral and truncal blocks in pediatric patients

    Directory of Open Access Journals (Sweden)

    Mohamed Bilal Delvi

    2011-01-01

    Full Text Available Ultrasound has added a feather in the cap of the anesthesiologists as real-time nerve localization and drug deposition around the nerve structure under real-time guidance is now a reality, as the saying "seeing is believing" has been proven true with the advent of ultrasound in anesthesia. Pediatric patients are a unique group regarding their anatomical and physiological features in comparison with adults; regional blocks in adults with the anatomical landmark and surface marking are almost uniform across the adult population. The landmark technique in pediatric patients is not reliable in all patients due to the variability in the age and size; the advent of ultrasound in assisting nerve localization has changed the way regional blocks are achieved in children and the range of blocks performed on adults can now be performed on pediatric patients; with advances in the technology and dexterity of ultrasound equipment, the chances of success of blocks has increased with a smaller dose of the local anesthetic in comparison to the traditional methods. Anesthesiologists are now able to perform blocks with more accuracy and avoid complications like intravascular injection and injury to the pleura and peritoneum during routine practice with the assistance of high-frequency transducers and top of the range portable ultrasound machines; catheters can be inserted to provide a continuous analgesia in the postoperative period. This review article describes the common peripheral blocks in pediatric patients; the readers are encouraged to gain experience by attending workshops, hands-on practice under supervision, and conduct random controlled trials pertaining to ultrasound-guided blocks in the pediatric age group. The recent literature is encouraging and further research is promising; a wide range of blocks being described in detail by many prominent experts from all over the world.

  11. A clinical assessment tool for ultrasound-guided axillary brachial plexus block.

    LENUS (Irish Health Repository)

    Sultan, S F

    2012-05-01

    Competency in anesthesia traditionally has been determined subjectively in practice. Optimal training in procedural skills requires valid and reliable forms of assessment. The objective was to examine a procedure-specific clinical assessment tool for ultrasound-guided axillary brachial plexus block for inter-rater reliability and construct validity in a clinical setting.

  12. Effects of microchannel confinement on acoustic vaporisation of ultrasound phase change contrast agents

    Science.gov (United States)

    Lin, Shengtao; Zhang, Ge; Hau Leow, Chee; Tang, Meng-Xing

    2017-09-01

    The sub-micron phase change contrast agent (PCCA) composed of a perfluorocarbon liquid core can be activated into gaseous state and form stable echogenic microbubbles for contrast-enhanced ultrasound imaging. It has shown great promise in imaging microvasculature, tumour microenvironment, and cancer cells. Although PCCAs have been extensively studied for different diagnostic and therapeutic applications, the effect of biologically geometrical confinement on the acoustic vaporisation of PCCAs is still not clear. We have investigated the difference in PCCA-produced ultrasound contrast enhancement after acoustic activation with and without a microvessel confinement on a microchannel phantom. The experimental results indicated more than one-order of magnitude less acoustic vaporisation in a microchannel than that in a free environment taking into account the attenuation effect of the vessel on the microbubble scattering. This may provide an improved understanding in the applications of PCCAs in vivo.

  13. Intra-articular distribution pattern after ultrasound-guided injections in wrist joints of patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Boesen, Mikael; Jensen, Karl Erik; Torp-Pedersen, Søren

    2007-01-01

    OBJECTIVE: To investigate the distribution of an ultrasound-guided intra-articular (IA) injection in the wrist joint of patients with rheumatoid arthritis (RA). METHODS: An ultrasound-guided IA drug injection into the wrist joint was performed in 17 patients with 1 ml methylprednisolone (40 mg...... with the MRI OMERACT synovitis score (r=0.60, p=0.014), but not with the erosions, bonemarrow oedema scores or any clinical parameters. CONCLUSION: The distribution of contrast on MRI showed patient specific and random patterns after IA injections in active RA wrist joints. The degree of distribution increased...

  14. In-Plane Ultrasound-Guided Knee Injection Through a Lateral Suprapatellar Approach: A Safe Technique.

    Science.gov (United States)

    Chagas-Neto, Francisco A; Taneja, Atul K; Gregio-Junior, Everaldo; Nogueira-Barbosa, Marcello H

    2017-06-01

    This study aims to describe a technique for in-plane ultrasound-guided knee arthrography through a lateral suprapatellar approach, reporting its accuracy and related complications. A retrospective search was performed for computed tomography and magnetic resonance reports from June 2013 through June 2015. Imaging studies, puncture descriptions, and guided-procedure images were reviewed along with clinical and surgical history. A fellowship-trained musculoskeletal radiologist performed all procedures under sterile technique and ultrasound guidance with the probe in oblique position on the lateral suprapatellar recess after local anesthesia with the patient on dorsal decubitus, hip in neutral rotation, and 30 to 45 degrees of knee flexion. A total of 86 consecutive subjects were evaluated (mean, 55 years). All subjects underwent intra-articular injection of contrast, which was successfully reached in the first attempt in 94.2% of the procedures (81/86), and in the second attempt in 5.8% (5/86) after needle repositioning without a second puncture. There were no postprocedural reports of regional complications at the puncture site, such as significant pain, bleeding, or vascular lesions. Our study demonstrates that in-plane ultrasound-guided injection of the knee in semiflexion approaching the lateral suprapatellar recess is a safe and useful technique to administer intra-articular contrast solution, as an alternative method without radiation exposure.

  15. Nova técnica para treinamento em acessos vasculares guiados por ultrassom utilizando modelo de tecido animal New technique for ultrasound-guided vascular access training using an animal tissue model

    Directory of Open Access Journals (Sweden)

    Robson Barbosa de Miranda

    2012-03-01

    Full Text Available A ultrassonografia Doppler deixou de ter seu uso apenas como método diagnóstico e vem galgando espaço nos procedimentos terapêuticos. Com maior aplicabilidade e uso de cateteres venosos centrais e procedimentos guiados por ultrassom, há preocupação com a melhora da eficácia e segurança durante o procedimento, assim como com a diminuição das potenciais complicações. Para isso, o treinamento da técnica em modelos (phantoms é desejável. Os modelos industrializados para treinamento em acesso vascular guiado por ultrassom são caros e não reproduzem adequadamente a ecotextura e a densidade dos tecidos humanos. Na tentativa de treinar e aprimorar os profissionais para o uso do ultrassom em procedimentos de acessos vasculares, desenvolveu-se um modelo animal de baixo custo, fácil confecção e excelente aplicabilidade.Duplex ultrasonography has not been used only as a noninvasive diagnostic method. Recently it has been applied for therapeutic procedures. Due to the increasing use and applicability of central venous catheters and eco-guided vascular procedures, there are concerns about improving results regarding accuracy and safety, reducing complication rates during those procedures. It would be desirable that training was accomplished using phantoms before actual procedures in human subjects. Industrialized phantoms are expensive and they do not reproduce human's ecographic density and texture. In order to train and improve ultrasound guided vascular access, we have developed a cheap animal tissue model, which is of easy preparation and applicability.

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) ...

  17. Role of ultrasound-guided continuous brachial plexus block in the management of neonatal ischemia in upper limb

    Directory of Open Access Journals (Sweden)

    Vrushali C Ponde

    2012-01-01

    Full Text Available Neonatal upper limb ischemia due to accidental arterial damage remains a major concern, which can lead to devastating complications if untreated. The primary objective of this case report is to emphasize the role of continuous infraclavicular brachial plexus block, the issues related with block performance in an ischemic hand, and the importance of ultrasound guidance in this particular case scenario. A 1.1 kg infant suffered from distal forearm ischemia due to accidental arterial damage, which was treated with brachial plexus block. An ultrasound-guided single shot block with 0.5 mL/kg of 0.25% bupivacaine was followed by ultrasound-guided catheter placement in the target area. A continuous infusion of 0.03% of bupivacaine at the rate of 0.5 mL/kg/hr (approx. 0.15 mg/kg/h of bupivacaine was administered for 36 h. This treatment resulted in reversal of ischemia. Permanent ischemic damage was eventually confined to the tips of 4 fingers. We conclude that ultrasound-guided continuous infraclavicular block has a therapeutic role to play in the treatment of hand ischemia due to arterial damage and subsequent arterial spasm in neonates with added benefits.

  18. Homemade ultrasound phantom for simulation of hydronephrosis

    Directory of Open Access Journals (Sweden)

    Ana Karine Brandao Novaes

    2018-05-01

    Full Text Available Abstract In this article, we describe the development of a simple and inexpensive simulation phantom as a surrogate of human hydronephrosis for the identification of urinary tract obstruction at bedside to be used in undergraduate training of medical students.

  19. Focal point determination in magnetic resonance-guided focused ultrasound using tracking coils.

    Science.gov (United States)

    Svedin, Bryant T; Beck, Michael J; Hadley, J Rock; Merrill, Robb; de Bever, Joshua T; Bolster, Bradley D; Payne, Allison; Parker, Dennis L

    2017-06-01

    To develop a method for rapid prediction of the geometric focus location in MR coordinates of a focused ultrasound (US) transducer with arbitrary position and orientation without sonicating. Three small tracker coil circuits were designed, constructed, attached to the transducer housing of a breast-specific MR-guided focused US (MRgFUS) system with 5 degrees of freedom, and connected to receiver channel inputs of an MRI scanner. A one-dimensional sequence applied in three orthogonal directions determined the position of each tracker, which was then corrected for gradient nonlinearity. In a calibration step, low-level heating located the US focus in one transducer position orientation where the tracker positions were also known. Subsequent US focus locations were determined from the isometric transformation of the trackers. The accuracy of this method was verified by comparing the tracking coil predictions to thermal center of mass calculated using MR thermometry data acquired at 16 different transducer positions for MRgFUS sonications in a homogeneous gelatin phantom. The tracker coil predicted focus was an average distance of 2.1 ± 1.1 mm from the thermal center of mass. The one-dimensional locator sequence and prediction calculations took less than 1 s to perform. This technique accurately predicts the geometric focus for a transducer with arbitrary position and orientation without sonicating. Magn Reson Med 77:2424-2430, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  20. Wear plates control rod guide tubes top internal reactor vessel C. N. VANDELLOS II

    International Nuclear Information System (INIS)

    2010-01-01

    The guide tubes for control rods forming part of the upper internals of the reactor vessel, its function is to guide the control rod to permit its insertion in the reactor core. These guide tubes are suspended from the upper support plate which are fixed by bolts and extending to the upper core plate which is fastened by clamping bolts (split pin) to prevent lateral displacement of the guide tubes, while allowing axial expansion.

  1. Targeted Ultrasound-Guided Perineural Hydrodissection of the Sciatic Nerve for the Treatment of Piriformis Syndrome.

    Science.gov (United States)

    Burke, Christopher J; Walter, William R; Adler, Ronald S

    2018-05-01

    Piriformis syndrome is a common cause of lumbar, gluteal, and thigh pain, frequently associated with sciatic nerve symptoms. Potential etiologies include muscle injury or chronic muscle stretching associated with gait disturbances. There is a common pathological end pathway involving hypertrophy, spasm, contracture, inflammation, and scarring of the piriformis muscle, leading to impingement of the sciatic nerve. Ultrasound-guided piriformis injections are frequently used in the treatment of these pain syndromes, with most of the published literature describing injection of the muscle. We describe a safe, effective ultrasound-guided injection technique for the treatment of piriformis syndrome using targeted sciatic perineural hydrodissection followed by therapeutic corticosteroid injection.

  2. High-intensity focused ultrasound ablation around the tubing.

    Science.gov (United States)

    Siu, Jun Yang; Liu, Chenhui; Zhou, Yufeng

    2017-01-01

    High-intensity focused ultrasound (HIFU) has been emerging as an effective and noninvasive modality in cancer treatment with very promising clinical results. However, a small vessel in the focal region could be ruptured, which is an important concern for the safety of HIFU ablation. In this study, lesion formation in the polyacrylamide gel phantom embedded with different tubing (inner diameters of 0.76 mm and 3 mm) at varied flow speeds (17-339 cm/s) by HIFU ablation was photographically recorded. Produced lesions have decreased length (~30%) but slightly increased width (~6%) in comparison to that without the embedded tubing. Meanwhile, bubble activities during the exposures were measured by passive cavitation detection (PCD) at the varied pulse repetition frequency (PRF, 10-30 Hz) and duty cycle (DC, 10%-20%) of the HIFU bursts. High DC and low flow speed were found to produce stronger bubble cavitation whereas no significant influence of the PRF. In addition, high-speed photography illustrated that the rupture of tubing was produced consistently after the first HIFU burst within 20 ms and then multiple bubbles would penetrate into the intraluminal space of tubing through the rupture site by the acoustic radiation force. Alignment of HIFU focus to the anterior surface, middle, and posterior surface of tubing led to different characteristics of vessel rupture and bubble introduction. In summary, HIFU-induced vessel rupture is possible as shown in this phantom study; produced lesion sizes and shapes are dependent on the focus alignment to the tubing, flow speed, and tubing properties; and bubble cavitation and the formation liquid jet may be one of the major mechanisms of tubing rupture as shown in the high-speed photography.

  3. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions.

    Science.gov (United States)

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure.

  4. Radiation damage characterization in reactor pressure vessel steels with nonlinear ultrasound

    International Nuclear Information System (INIS)

    Matlack, K. H.; Kim, J.-Y.; Wall, J. J.; Qu, J.; Jacobs, L. J.

    2014-01-01

    Nuclear generation currently accounts for roughly 20% of the US baseload power generation. Yet, many US nuclear plants are entering their first period of life extension and older plants are currently undergoing assessment of technical basis to operate beyond 60 years. This means that critical components, such as the reactor pressure vessel (RPV), will be exposed to higher levels of radiation than they were originally intended to withstand. Radiation damage in reactor pressure vessel steels causes microstructural changes such as vacancy clusters, precipitates, dislocations, and interstitial loops that leave the material in an embrittled state. The development of a nondestructive evaluation technique to characterize the effect of radiation exposure on the properties of the RPV would allow estimation of the remaining integrity of the RPV with time. Recent research has shown that nonlinear ultrasound is sensitive to radiation damage. The physical effect monitored by nonlinear ultrasonic techniques is the generation of higher harmonic frequencies in an initially monochromatic ultrasonic wave, arising from the interaction of the ultrasonic wave with microstructural features such as dislocations, precipitates, and their combinations. Current findings relating the measured acoustic nonlinearity parameter to increasing levels of neutron fluence for different representative RPV materials are presented

  5. Radiation damage characterization in reactor pressure vessel steels with nonlinear ultrasound

    Science.gov (United States)

    Matlack, K. H.; Kim, J.-Y.; Wall, J. J.; Qu, J.; Jacobs, L. J.

    2014-02-01

    Nuclear generation currently accounts for roughly 20% of the US baseload power generation. Yet, many US nuclear plants are entering their first period of life extension and older plants are currently undergoing assessment of technical basis to operate beyond 60 years. This means that critical components, such as the reactor pressure vessel (RPV), will be exposed to higher levels of radiation than they were originally intended to withstand. Radiation damage in reactor pressure vessel steels causes microstructural changes such as vacancy clusters, precipitates, dislocations, and interstitial loops that leave the material in an embrittled state. The development of a nondestructive evaluation technique to characterize the effect of radiation exposure on the properties of the RPV would allow estimation of the remaining integrity of the RPV with time. Recent research has shown that nonlinear ultrasound is sensitive to radiation damage. The physical effect monitored by nonlinear ultrasonic techniques is the generation of higher harmonic frequencies in an initially monochromatic ultrasonic wave, arising from the interaction of the ultrasonic wave with microstructural features such as dislocations, precipitates, and their combinations. Current findings relating the measured acoustic nonlinearity parameter to increasing levels of neutron fluence for different representative RPV materials are presented.

  6. Evaluation of the UF/NCI hybrid computational phantoms for use in organ dosimetry of pediatric patients undergoing fluoroscopically guided cardiac procedures

    Science.gov (United States)

    Marshall, Emily L.; Borrego, David; Tran, Trung; Fudge, James C.; Bolch, Wesley E.

    2018-03-01

    Epidemiologic data demonstrate that pediatric patients face a higher relative risk of radiation induced cancers than their adult counterparts at equivalent exposures. Infants and children with congenital heart defects are a critical patient population exposed to ionizing radiation during life-saving procedures. These patients will likely incur numerous procedures throughout their lifespan, each time increasing their cumulative radiation absorbed dose. As continued improvements in long-term prognosis of congenital heart defect patients is achieved, a better understanding of organ radiation dose following treatment becomes increasingly vital. Dosimetry of these patients can be accomplished using Monte Carlo radiation transport simulations, coupled with modern anatomical patient models. The aim of this study was to evaluate the performance of the University of Florida/National Cancer Institute (UF/NCI) pediatric hybrid computational phantom library for organ dose assessment of patients that have undergone fluoroscopically guided cardiac catheterizations. In this study, two types of simulations were modeled. A dose assessment was performed on 29 patient-specific voxel phantoms (taken as representing the patient’s true anatomy), height/weight-matched hybrid library phantoms, and age-matched reference phantoms. Two exposure studies were conducted for each phantom type. First, a parametric study was constructed by the attending pediatric interventional cardiologist at the University of Florida to model the range of parameters seen clinically. Second, four clinical cardiac procedures were simulated based upon internal logfiles captured by a Toshiba Infinix-i Cardiac Bi-Plane fluoroscopic unit. Performance of the phantom library was quantified by computing both the percent difference in individual organ doses, as well as the organ dose root mean square values for overall phantom assessment between the matched phantoms (UF/NCI library or reference) and the patient

  7. Minimum Effective Volume of Lidocaine for Ultrasound-Guided Costoclavicular Block.

    Science.gov (United States)

    Sotthisopha, Thitipan; Elgueta, Maria Francisca; Samerchua, Artid; Leurcharusmee, Prangmalee; Tiyaprasertkul, Worakamol; Gordon, Aida; Finlayson, Roderick J; Tran, De Q

    This dose-finding study aimed to determine the minimum effective volume in 90% of patients (MEV90) of lidocaine 1.5% with epinephrine 5 μg/mL for ultrasound-guided costoclavicular block. Using an in-plane technique and a lateral-to-medial direction, the block needle was positioned in the middle of the 3 cords of the brachial plexus in the costoclavicular space. The entire volume of lidocaine was deposited in this location. Dose assignment was carried out using a biased-coin-design up-and-down sequential method, where the total volume of local anesthetic administered to each patient depended on the response of the previous one. In case of failure, the next subject received a higher volume (defined as the previous volume with an increment of 2.5 mL). If the previous patient had a successful block, the next subject was randomized to a lower volume (defined as the previous volume with a decrement of 2.5 mL), with a probability of b = 0.11, or the same volume, with a probability of 1 - b = 0.89. Success was defined, at 30 minutes, as a minimal score of 14 of 16 points using a sensorimotor composite scale. Patients undergoing surgery of the elbow, forearm, wrist, or hand were prospectively enrolled until 45 successful blocks were obtained. This clinical trial was registered with ClinicalTrials.gov (ID NCT02932670). Fifty-seven patients were included in the study. Using isotonic regression and bootstrap confidence interval, the MEV90 for ultrasound-guided costoclavicular block was estimated to be 34.0 mL (95% confidence interval, 33.4-34.4 mL). All patients with a minimal composite score of 14 points at 30 minutes achieved surgical anesthesia intraoperatively. For ultrasound-guided costoclavicular block, the MEV90 of lidocaine 1.5% with epinephrine 5 μg/mL is 34 mL. Further dose-finding studies are required for other concentrations of lidocaine, other local anesthetic agents, and multiple-injection techniques.

  8. Ultrasound-Guided Fine-Needle Aspiration Biopsy of Multiple Thyroid Nodules

    International Nuclear Information System (INIS)

    Kim, Ji Dae; Bae, Il Hun; Lee, Seung Young; Han, Gi Seok; Cha, Sang Hun; Kim, Sung Jin; Park, Kil Sun; Koong, Sung Soo; Lee, Ok Jun

    2006-01-01

    To standardize the number of nodules which necessitates ultrasound-guided, fine-needle, aspiration biopsy in patients who have multiple thyroid nodules with the same sonographic characteristics as each other. From February, 2002 to March, 2004, among patients whose diagnosis was confirmed by ultrasound-guided, fine-needle, aspiration biopsy, 545 nodules of 203 patients were found in sonography with more than two thyroid nodules. Each thyroid gland nodule was classified on a score from 0 to 2 points on the basis of the following 5 characteristics: internal content, margin, echogenicity, shape and calcification in sonography. When the score of all characteristics was the same, by deciding on nodules with the same sonographic characteristics and with the score of at least one characteristic being different, we divided the nodules with different sonographic characteristics in a patient. By methods such as given in the preceding descriptions, patients with multiple thyroid nodules were separated into two groups: one in which all nodules had the same sonographic characteristics and another in which nodules have at least one different sonographic characteristic. Then, each pathologic result was searched for the same case and different case in each patient group. Among the 203 patients who were diagnosed with multiple thyroid nodules in ultrasonography, 79 patients (38.9%) had nodules with the same ultrasonographic characteristics and 124 patients (61.1%) had nodules with at least one different ultrasonographic characteristic. All 79 patient's nodules with the same ultrasonographic characteristics in each patient showed the same pathologic result in all cases (100.0%) and there was no case showing a different pathologic result. Otherwise, among the 124 patient's nodules with different ultrasonographic characteristics, each patient showed the same pathologic result in 111 (89.5%) and different pathologic result in 13 (10.5%). In patients who have multiple thyroid nodules

  9. A simulation technique for 3D MR-guided acoustic radiation force imaging

    International Nuclear Information System (INIS)

    Payne, Allison; Bever, Josh de; Farrer, Alexis; Coats, Brittany; Parker, Dennis L.; Christensen, Douglas A.

    2015-01-01

    Purpose: In magnetic resonance-guided focused ultrasound (MRgFUS) therapies, the in situ characterization of the focal spot location and quality is critical. MR acoustic radiation force imaging (MR-ARFI) is a technique that measures the tissue displacement caused by the radiation force exerted by the ultrasound beam. This work presents a new technique to model the displacements caused by the radiation force of an ultrasound beam in a homogeneous tissue model. Methods: When a steady-state point-source force acts internally in an infinite homogeneous medium, the displacement of the material in all directions is given by the Somigliana elastostatic tensor. The radiation force field, which is caused by absorption and reflection of the incident ultrasound intensity pattern, will be spatially distributed, and the tensor formulation takes the form of a convolution of a 3D Green’s function with the force field. The dynamic accumulation of MR phase during the ultrasound pulse can be theoretically accounted for through a time-of-arrival weighting of the Green’s function. This theoretical model was evaluated experimentally in gelatin phantoms of varied stiffness (125-, 175-, and 250-bloom). The acoustic and mechanical properties of the phantoms used as parameters of the model were measured using independent techniques. Displacements at focal depths of 30- and 45-mm in the phantoms were measured by a 3D spin echo MR-ARFI segmented-EPI sequence. Results: The simulated displacements agreed with the MR-ARFI measured displacements for all bloom values and focal depths with a normalized RMS difference of 0.055 (range 0.028–0.12). The displacement magnitude decreased and the displacement pattern broadened with increased bloom value for both focal depths, as predicted by the theory. Conclusions: A new technique that models the displacements caused by the radiation force of an ultrasound beam in a homogeneous tissue model theory has been rigorously validated through comparison

  10. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology

    DEFF Research Database (Denmark)

    Dumonceau, Jean-Marc; Deprez, Pierre H; Jenssen, Christian

    2017-01-01

    For pancreatic solid lesions, ESGE recommends performing endoscopic ultrasound (EUS)-guided sampling as first-line procedure when a pathological diagnosis is required. Alternatively, percutaneous sampling may be considered in metastatic disease.Strong recommendation, moderate quality evidence.In ...

  11. Ultrasound-guided hydrostatic reduction of intussusception with saline: Safe and effective.

    Science.gov (United States)

    Karadağ, Çetin Ali; Abbasoğlu, Latif; Sever, Nihat; Kalyoncu, Meltem Kaba; Yıldız, Abdullah; Akın, Melih; Candan, Mustafa; Dokucu, Ali İhsan

    2015-09-01

    The study was undertaken to assess the efficacy of ultrasound-guided saline enema in reducing intussusception and to determine the role of age and duration of symptoms on this event. The case records of patients who were treated for intussusception at our institutions over the past 10 years were retrospectively analyzed. A total of 419 patients were treated for intussusception and 375 of them were included into the study. Patients were excluded if they had symptoms and signs of acute abdominal disease and required surgery as an initial treatment. Hydrostatic reduction was successful in 313 of the 375 patients (83.46%). The procedure-related complication rate was nil. There were 29 episodes of recurrences in 23 patients, and recurrence rates did not differ between patients who responded to hydrostatic reduction and those who required surgery. Younger age [median (range); 11 months (3-108 months) vs. 20 months (1-180 months); phydrostatic reduction. Ultrasound-guided hydrostatic reduction is an easy, safe and effective method for the treatment of intussusception in the absence of acute abdominal findings. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Remote just-in-time telementored trauma ultrasound: a double-factorial randomized controlled trial examining fluid detection and remote knobology control through an ultrasound graphic user interface display.

    Science.gov (United States)

    Kirkpatrick, Andrew W; McKee, Ian; McKee, Jessica L; Ma, Irene; McBeth, Paul B; Roberts, Derek J; Wurster, Charles L; Parfitt, Robbie; Ball, Chad G; Oberg, Scott; Sevcik, William; Hamilton, Douglas R

    2016-05-01

    Remote-telementored ultrasound involves novice examiners being remotely guided by experts using informatic-technologies. However, requiring a novice to perform ultrasound is a cognitively demanding task exacerbated by unfamiliarity with ultrasound-machine controls. We incorporated a randomized evaluation of using remote control of the ultrasound functionality (knobology) within a study in which the images generated by distant naive examiners were viewed on an ultrasound graphic user interface (GUI) display viewed on laptop computers by mentors in different cities. Fire-fighters in Edmonton (101) were remotely mentored from Calgary (n = 65), Nanaimo (n = 19), and Memphis (n = 17) to examine an ultrasound phantom randomized to contain free fluid or not. Remote mentors (2 surgeons, 1 internist, and 1 ED physician) were randomly assigned to use GUI knobology control during mentoring (GUIK+/GUIK-). Remote-telementored ultrasound was feasible in all cases. Overall accuracy for fluid detection was 97% (confidence interval = 91 to 99%) with 3 false negatives (FNs). Positive/negative likelihood ratios were infinity/0.0625. One FN occurred with the GUIK+ and 2 without (GUIK-). There were no statistical test performance differences in either group (GUIK+ and GUIK-). Ultrasound-naive 1st responders can be remotely mentored with high accuracy, although providing basic remote control of the knobology did not affect outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. A comparison between plaque-based and vessel-based measurement for plaque component using volumetric intravascular ultrasound radiofrequency data analysis.

    Science.gov (United States)

    Shin, Eun-Seok; Garcia-Garcia, Hector M; Garg, Scot; Serruys, Patrick W

    2011-04-01

    Although percent plaque components on plaque-based measurement have been used traditionally in previous studies, the impact of vessel-based measurement for percent plaque components have yet to be studied. The purpose of this study was therefore to correlate percent plaque components derived by plaque- and vessel-based measurement using intravascular ultrasound virtual histology (IVUS-VH). The patient cohort comprised of 206 patients with de novo coronary artery lesions who were imaged with IVUS-VH. Age ranged from 35 to 88 years old, and 124 patients were male. Whole pullback analysis was used to calculate plaque volume, vessel volume, and absolute and percent volumes of fibrous, fibrofatty, necrotic core, and dense calcium. The plaque and vessel volumes were well correlated (r = 0.893, P measurement was also highly correlated with vessel-based measurement. Therefore, the percent plaque component volume calculated by vessel volume could be used instead of the conventional percent plaque component volume calculated by plaque volume.

  14. Central lung tumors with obstructive pneumonitis; ultrasonographic findings and usefulness of ultrasound-guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong An; Kim, Sun Su; Seon, Young Seok; Lee, Kyoung Rok; Kim, Byoung Geun; Park, Byung Ran; Kim, Se Jong [Kwangju Christian Hospital, Kwangju (Korea, Republic of)

    2001-02-01

    To determine the ultrasonographic findings and assess the usefulness of ultrasound (US)-guided biopsy of central lung tumors in patients with obstructive pneumonitis. Fourteen patients with central lung tumors causing obstructive pneumonitis, as seen on chest radiographs and chest CT scans, were examined between January 1997 and January 2000. In no patient conclusive histologic diagnosis obtained by means of bronchoscopic biopsy or sputum cytology. Eleven patients were men and three were women, and their ages ranged from 45 to 83 (mean, 64) years. For all examinations, real-time, linear-array, convex US units with a 3.75-and a 5.0-MHz transducer were used. The images obtained were analyzed for evidence of consolidation or atelectasis in the lung, demonstrable tumors, and tumor size and echogenicity. For US-guided percutaneous transthoracic biopsy, 19.5G automatic biopsy devices, were employed. Lung consolidation due to a wedge-shaped, homogeneous, hypoechoic lesion was revealed by sonographic fluid bronchograms, air bronchograms, air alvelograms, and visualization of intraparenchymal pulmonary vessels, which showed appropriate motion with respiration. The tumor presumed to be causing obstruction was seen as a hypoechoic nodule near the hilum or as a well-defined hyperechoic mass inside the partially consolidated lung. Pleural effusion was observed in one case. The cytologic findings indicated the presence of squamous cell carcinoma (n=4), adenocarcinoma (n=4), small cell carcinoma (n=3), non-small cell carcinoma (n=2) and large cell carcinoma (n=1). The success rate was 100%, and there were no complications. In patients with central lung tumors causing obstructive pneumonitis, chest ultrasonography and US-guided biopsy are useful adjunctive diagnostic modalities and techniques.

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... inserted into a man's rectum to view the prostate. Transvaginal ultrasound. The transducer is inserted into a ... Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos ...

  16. A serious game for learning ultrasound-guided needle placement skills.

    Science.gov (United States)

    Chan, Wing-Yin; Qin, Jing; Chui, Yim-Pan; Heng, Pheng-Ann

    2012-11-01

    Ultrasound-guided needle placement is a key step in a lot of radiological intervention procedures such as biopsy, local anesthesia and fluid drainage. To help training future intervention radiologists, we develop a serious game to teach the skills involved. We introduce novel techniques for realistic simulation and integrate game elements for active and effective learning. This game is designed in the context of needle placement training based on the some essential characteristics of serious games. Training scenarios are interactively generated via a block-based construction scheme. A novel example-based texture synthesis technique is proposed to simulate corresponding ultrasound images. Game levels are defined based on the difficulties of the generated scenarios. Interactive recommendation of desirable insertion paths is provided during the training as an adaptation mechanism. We also develop a fast physics-based approach to reproduce the shadowing effect of needles in ultrasound images. Game elements such as time-attack tasks, hints and performance evaluation tools are also integrated in our system. Extensive experiments are performed to validate its feasibility for training.

  17. Ultrasound-guided, vacuum-assisted biopsy in evaluation of breast lesions

    International Nuclear Information System (INIS)

    Luczynska, E.; Kocurek, A.; Dyczek, S.; Skotnicki, P.; Stelmach, A.; Herman, K.

    2008-01-01

    Aim. Evaluation of the efficacy of ultrasound-guided vacuum-assisted biopsy for the verification of breast lesions. Introduction. Ultrasound breast examination is a noninvasive method of breast imaging. It is adjunct to mammography and physical examination and, in women under 30 years of age, pregnant and lactating, it is the basic examination used for the detection and diagnosing of breast diseases. It allows also to obtain cells or tissue samples with such minimally invasive techniques as fine-needle biopsy, core needle biopsy or vacuum-assisted biopsy. Material and methods. The study group consisted of 138 women, aged from 20 to 76 years, who underwent ultrasound guided vacuum-assisted biopsy between March and December 2006. Because double lesions were diagnosed in 6 patients, this resulted in 144 performed procedures. Each patient underwent ultrasound examination, performed with a 10-12 MHz transducer. Biopsies were guided by a 12 MHz transducer and performed with the Mammotome System using an 11G or an 8G needle, depending upon the size and site of the lesion. Obtained data were compared using the Chi-square test; p values of less than 0.05 were considered indicative of a significant difference. Results. The average size of the biopted lesions was estimated as 11±3,8 mm (range: 4-30 mm). However, lesions described by radiologists as apparently suspicious were not qualified for the vacuum-assisted biopsy, in the tested material 4 lesions appeared to be carcinomas (3 were invasive breast carcinomas and 1 was ductal carcinoma in situ). When compared with other changes, these lesions were most frequently equivocal (3 vs 1 determined as benign, p=0.014). There was no statistically significant difference in echogenicity (3 hypoechoic vs 1 with mixed echogenicity) nor in the shape (1 oval change, 2 lobulated and 1 irregular). Pathological examination revealed 86 cases of fibroadenoma within the tested material. Those lesions were mostly benign (77 vs 9 equivocal

  18. Technical Note: Error metrics for estimating the accuracy of needle/instrument placement during transperineal magnetic resonance/ultrasound-guided prostate interventions.

    Science.gov (United States)

    Bonmati, Ester; Hu, Yipeng; Villarini, Barbara; Rodell, Rachael; Martin, Paul; Han, Lianghao; Donaldson, Ian; Ahmed, Hashim U; Moore, Caroline M; Emberton, Mark; Barratt, Dean C

    2018-04-01

    Image-guided systems that fuse magnetic resonance imaging (MRI) with three-dimensional (3D) ultrasound (US) images for performing targeted prostate needle biopsy and minimally invasive treatments for prostate cancer are of increasing clinical interest. To date, a wide range of different accuracy estimation procedures and error metrics have been reported, which makes comparing the performance of different systems difficult. A set of nine measures are presented to assess the accuracy of MRI-US image registration, needle positioning, needle guidance, and overall system error, with the aim of providing a methodology for estimating the accuracy of instrument placement using a MR/US-guided transperineal approach. Using the SmartTarget fusion system, an MRI-US image alignment error was determined to be 2.0 ± 1.0 mm (mean ± SD), and an overall system instrument targeting error of 3.0 ± 1.2 mm. Three needle deployments for each target phantom lesion was found to result in a 100% lesion hit rate and a median predicted cancer core length of 5.2 mm. The application of a comprehensive, unbiased validation assessment for MR/US guided systems can provide useful information on system performance for quality assurance and system comparison. Furthermore, such an analysis can be helpful in identifying relationships between these errors, providing insight into the technical behavior of these systems. © 2018 American Association of Physicists in Medicine.

  19. Long-term follow-up of ultrasound-guided botulinum toxin-A injections for sialorrhea in neurological dysphagia.

    Science.gov (United States)

    Barbero, Pierangelo; Busso, Marco; Tinivella, Marco; Artusi, Carlo Alberto; De Mercanti, Stefania; Cucci, Angele; Veltri, Andrea; Avagnina, Paolo; Calvo, Andrea; Chio', Adriano; Durelli, Luca; Clerico, Marinella

    2015-12-01

    Literature provides reports only of a limited follow-up single injection of botulinum toxin-A (BoNT-A) in patients with sialorrhea. The aim of our study is to evaluate the long-lasting efficacy and safety of ultrasound-guided BoNT-A injections for severe sialorrhea secondary to neurological dysphagia. We enrolled 38 severe adult sialorrhea patients referred consecutively to the neurology unit and performed bilateral parotid and submandibular gland BoNT-A injections under ultrasound guidance. The outcomes of the study were reduction of sialorrhea, duration of therapeutic effect, and subjective patient- and caregiver-reported satisfaction. A total of 113 BoNT-A administrations were given during the study period with a mean duration of follow-up of 20.2 ± 4.4 months. We observed a significant decrease from baseline in mean number of daily aspirations and a significant improvement in patient- and caregiver-reported outcomes following ultrasound-guided BoNT-A injections (p < 0.001 vs baseline for all comparisons) and the mean duration of the efficacy was 5.6 ± 1 months. No major treatment-related adverse events occurred and a low incidence of minor adverse events was reported. This study confirms the long-lasting efficacy and safety of ultrasound-guided BoNT-A injections for sialorrhea, regardless of the causative neurological disorder. These results should encourage the use of BoNT-A in the treatment of severe sialorrhea and highlight the role of ultrasound guidance to obtain optimal results in terms of safety and reproducible outcomes.

  20. Ultrasound elastography: advantages, limitations and artefacts of the different techniques from a study on a phantom.

    Science.gov (United States)

    Franchi-Abella, S; Elie, C; Correas, J-M

    2013-05-01

    Ultrasound elastography is a technique currently under development. Its use in clinical practice is complicated because of the wide range of techniques used by the different manufacturers and the parameters proposed to characterise tissues. A comparative analysis on five ultrasound diagnostic systems has been performed on a calibrated elasticity phantom and demonstrated that: (1) all systems tested are reliable for simple qualitative analysis: is a nodule present and is it harder or softer than neighbouring tissues? (2) the deformation or hardness ratios between two regions are usually, however, not proportional to the theoretical ratios and only a binary analysis greater than 1 (harder) and less than 1 (softer) is reliable and could be used as a negative predictive value (NPV) for malignant lesions, as has been suggested by some authors; (3) finally, quantitative analysis using shear wave techniques performed variably, reliable measurements being obtained with only one of the systems. Measurements produced by these different systems must not be compared in clinical practice to monitor a patient and the threshold values proposed in the literature must only be used in an analysis carried out with the same system and same probe. Copyright © 2013 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  1. Effectiveness of imaging-guided intra-articular injection: a comparison study between fluoroscopy and ultrasound.

    Science.gov (United States)

    Furtado, Rita Nely Vilar; Pereira, Daniele Freitas; da Luz, Karine Rodrigues; dos Santos, Marla Francisca; Konai, Monique Sayuri; Mitraud, Sonia de Aguiar Vilela; Rosenfeld, Andre; Fernandes, Artur da Rocha Correa; Natour, Jamil

    2013-01-01

    Compare the effectiveness of ultrasound and fluoroscopy to guide intra-articular injections (IAI) in selected cases. A prospective study in our outpatient clinics at the Rheumatology Division at Universidade Federal de São Paulo (UNIFESP), Brazil, was conducted to compare the short-term (4 weeks) effectiveness of ultrasound and fluoroscopy-guided IAI in patients with rheumatic diseases. Inclusion criteria were: adults with refractory synovitis undergoing IAI with glucocorticoid. All patients had IAI performed with triamcinolone hexacetonide (20mg/ml) with varying doses according to the joint injected. A total of 71 rheumatic patients were evaluated (52 women, 44 whites). Mean age was 51.9 ± 13 years and 47 of them (66.2%) were on regular DMARD use. Analysis of the whole sample (71 patients) and hip sub-analysis (23 patients) showed that significant improvement was observed for both groups in terms of pain (P < 0.001). Global analysis also demonstrated better outcomes for patients in the FCG in terms of joint flexion (P < 0.001) and percentage change in joint flexion as compared to the USG. Likert scale score analyses demonstrated better results for the patients in the USG as compared to the FCG at the end of the study (P < 0.05). No statistically significant difference between groups was observed for any other study variable. Imaging-guided IAI improves regional pain in patients with various types of synovitis in the short term. For the vast majority of variables, no significant difference in terms of effectiveness was observed between fluoroscopy and ultrasound guided IAI.

  2. Detecting failed elements on phased array ultrasound transducers using the Edinburgh Pipe Phantom

    Science.gov (United States)

    Inglis, Scott; Pye, Stephen D

    2016-01-01

    Aims Imaging faults with ultrasound transducers are common. Failed elements on linear and curvilinear array transducers can usually be detected with a simple image uniformity or ‘paperclip’ test. However, this method is less effective for phased array transducers, commonly used in cardiac imaging. The aim of this study was to assess whether the presence of failed elements could be detected through measurement of the resolution integral (R) using the Edinburgh Pipe Phantom. Methods A 128-element paediatric phased array transducer was studied. Failed elements were simulated using layered polyvinyl chloride (PVC) tape as an attenuator and measurements of resolution integral were carried out for several widths of attenuator. Results All widths of attenuator greater than 0.5 mm resulted in a significant reduction in resolution integral and low contrast penetration measurements compared to baseline (p tests to detect failed elements on phased array transducers. Particularly encouraging is the result for low contrast penetration as this is a quick and simple measurement to make and can be performed with many different test objects, thus enabling ‘in-the-field’ checks. PMID:27482276

  3. Ultrasound-Guided Femoral Nerve Block to Facilitate the Closed Reduction of a Dislocated Hip Prosthesis

    Directory of Open Access Journals (Sweden)

    Edward Carlin

    2017-10-01

    Full Text Available Prosthetic hip dislocation is a common but unfortunate complication in patients who have undergone total hip arthroplasty. Successful closed reduction in the emergency department leads to a reduced length of stay and rate of hospitalization. 1, 2 The use of regional anesthesia by femoral nerve block represents a novel approach for controlling pain in patients with hip pathologies. 3 Ultrasound-guided approaches have been used with great success for controlling pain in patients with hip fractures. 4, 5 Here we report the case of a 90-year-old male who presented with a dislocated hip prosthesis, which was subsequently corrected with closed reduction following delivery of regional anesthesia to the femoral nerve under ultrasound guidance. To our knowledge, this represents the first reported use of an ultrasound-guided femoral nerve block to facilitate closed reduction of a dislocated prosthetic hip, and highlights a novel approach that avoids the use of procedural sedation in an elderly patient.

  4. MR-Guided Pulsed High-Intensity Focused Ultrasound Enhancement of Gene Therapy Combined With Androgen Deprivation and Radiotherapy for Prostate Cancer Treatment

    Science.gov (United States)

    2009-09-01

    ultrasound . J. Acoust. Soc.Am. 72 1926-1932, (1982) (7) Neppiras E A. Acoustic cavitation . Physics reports 61(3): 159-251, (1980) (8) ter Haar G R, Daniels...Guided Pulsed High-Intensity Focused Ultrasound Enhancement of 5b. GRANT NUMBER W81XWH-08-1-0469 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT...failing to This work is aimed to study MR guided high intensity focused ultrasound (MRgHIFU) enhancement of gene therapy for Prostate Cancer. The

  5. Analgesic effect of ultrasound-guided transversus abdominis plane block after total abdominal hysterectomy

    DEFF Research Database (Denmark)

    Røjskjaer, Jesper O; Gade, Erik; Kiel, Louise B

    2015-01-01

    OBJECTIVE: To assess the effect of bilateral ultrasound-guided transversus abdominis plane block with ropivacaine compared with placebo as part of a multimodal analgesic regimen. DESIGN: A randomized, double-blind, placebo-controlled trial following the CONSORT criteria. SETTING: Hvidovre Univers...

  6. Evaluation of a Standardized Program for Training Practicing Anesthesiologists in Ultrasound-Guided Regional Anesthesia Skills.

    Science.gov (United States)

    Mariano, Edward R; Harrison, T Kyle; Kim, T Edward; Kan, Jack; Shum, Cynthia; Gaba, David M; Ganaway, Toni; Kou, Alex; Udani, Ankeet D; Howard, Steven K

    2015-10-01

    Practicing anesthesiologists have generally not received formal training in ultrasound-guided perineural catheter insertion. We designed this study to determine the efficacy of a standardized teaching program in this population. Anesthesiologists in practice for 10 years or more were recruited and enrolled to participate in a 1-day program: lectures and live-model ultrasound scanning (morning) and faculty-led iterative practice and mannequin-based simulation (afternoon). Participants were assessed and recorded while performing ultrasound-guided perineural catheter insertion at baseline, at midday (interval), and after the program (final). Videos were scored by 2 blinded reviewers using a composite tool and global rating scale. Participants were surveyed every 3 months for 1 year to report the number of procedures, efficacy of teaching methods, and implementation obstacles. Thirty-two participants were enrolled and completed the program; 31 of 32 (97%) completed the 1-year follow-up. Final scores [median (10th-90th percentiles)] were 21.5 (14.5-28.0) of 30 points compared to 14.0 (9.0-20.0) at interval (P < .001 versus final) and 12.0 (8.5-17.5) at baseline (P < .001 versus final), with no difference between interval and baseline. The global rating scale showed an identical pattern. Twelve of 26 participants without previous experience performed at least 1 perineural catheter insertion after training (P < .001). However, there were no differences in the monthly average number of procedures or complications after the course when compared to baseline. Practicing anesthesiologists without previous training in ultrasound-guided regional anesthesia can acquire perineural catheter insertion skills after a 1-day standardized course, but changing clinical practice remains a challenge. © 2015 by the American Institute of Ultrasound in Medicine.

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... move through vessels. The movement of blood cells causes a change in pitch of the reflected sound ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... size, shape and consistency (whether the object is solid or filled with fluid). In medicine, ultrasound is ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ... structure and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound ...

  10. Magnetic resonance–guided interstitial high-intensity focused ultrasound for brain tumor ablation

    Science.gov (United States)

    MacDonell, Jacquelyn; Patel, Niravkumar; Rubino, Sebastian; Ghoshal, Goutam; Fischer, Gregory; Burdette, E. Clif; Hwang, Roy; Pilitsis, Julie G.

    2018-01-01

    Currently, treatment of brain tumors is limited to resection, chemotherapy, and radiotherapy. Thermal ablation has been recently explored. High-intensity focused ultrasound (HIFU) is being explored as an alternative. Specifically, the authors propose delivering HIFU internally to the tumor with an MRI-guided robotic assistant (MRgRA). The advantage of the authors’ interstitial device over external MRI-guided HIFU (MRgHIFU) is that it allows for conformal, precise ablation and concurrent tissue sampling. The authors describe their workflow for MRgRA HIFU delivery. PMID:29385926

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... testing. image the breasts and guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  12. Endoscopic ultrasound-guided radiofrequency ablation of the pancreas

    DEFF Research Database (Denmark)

    Silviu, Ungureanu Bogdan; Daniel, Pirici; Claudiu, Mărgăritescu

    2015-01-01

    ultrasound (EUS)-guided radiofrequency ablation (RFA) probe through a 19G needle in order to achieve a desirable necrosis area in the pancreas. Radiofrequency ablation of the head of the pancreas was performed on 10 Yorkshire pigs with a weight between 25 kg and 35 kg and a length of 40-70 cm. Using an EUS...... analysis revealed increased values of amylase, alkaline phosphatase, and gamma-glutamyl transpeptidase on the 3rd day but a decrease on the 5th day. After necropsy and isolation of the pancreas, the ablated area was easily found, describing a solid necrosis. The pathological examination revealed...

  13. Ultrasound-Guided Intermediate Site Greater Occipital Nerve Infiltration: A Technical Feasibility Study.

    Science.gov (United States)

    Zipfel, Jonathan; Kastler, Adrian; Tatu, Laurent; Behr, Julien; Kechidi, Rachid; Kastler, Bruno

    2016-01-01

    Two studies recently reported that computed tomography (CT) guided infiltration of the greater occipital nerve at its intermediate site allows a high efficacy rate with long-lasting pain relief following procedure in occipital neuralgia and in various craniofacial pain syndromes. The purpose of our study was to evaluate the technical feasibility and safety of ultrasound-guided intermediate site greater occipital nerve infiltration. Retrospective study. This study was conducted at the imaging department of a 1,409 bed university hospital. Local institutional review board approval was obtained and written consent was waived. In this retrospective study, 12 patients suffering from refractory occipital neuralgia or craniofacial pain syndromes were included between April and October 2014. They underwent a total of 21 ultrasound-guided infiltrations. Infiltration of the greater occipital nerve was performed at the intermediate site of the greater occipital nerve, at its first bend between obliqus capitis inferior and semispinalis capitis muscles with local anestetics and cortivazol. Technical success was defined as satisfactory diffusion of added iodinated contrast media in the fatty space between these muscles depicted on control CT scan. We also reported first data of immediate block test efficacy and initial clinical efficacy at 7 days, one month, and 3 months, defined by a decrease of at least 50% of visual analog scale (VAS) scores. Technical success rate was 95.24%. Patients suffered from right unilateral occipital neuralgia in 3 cases, left unilateral occipital neuralgia in 2 cases, bilateral occipital neuralgia in 2 cases, migraine in one case, cervicogenic headache in one case, tension-type headache in 2 cases, and cluster headache in one case. Block test efficacy was found in 93.3% (14/15) cases. Clinical efficacy was found in 80% of cases at 7 days, in 66.7% of cases at one month and in 60% of cases at 3 months. No major complications were noted. Some of the

  14. How to learn and to perform endoscopic ultrasound and endobronchial ultrasound for lung cancer staging

    DEFF Research Database (Denmark)

    Konge, Lars; Colella, Sara; Vilmann, Peter

    2015-01-01

    The learning of transesophageal ultrasound guided fine needle aspiration (FNA) (endoscopic ultrasound-FNA), and endobronchial ultrasound guided transbronchial needle aspiration (endosonography) should be based on the following steps: Acquiring theoretical knowledge, training on simulators, and su...

  15. Individualized laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer.

    Science.gov (United States)

    Xu, Zhifeng; Yang, Zhangwei; Pan, Jianghua; Hu, Yiren

    2018-03-01

    Liver cancer is one of the most common malignancies of the digestive system. Minimally invasive ablation procedures have become one of the major means for treating unresectable multifocal liver cancer and have been extensively applied in primary and metastatic liver cancer treatment. Laparoscopic B-ultrasound-guided microwave ablation is an example of the progress made in this field. To analyze and summarize the results of and experience with laparoscopic B-ultrasound-guided microwave ablation for multifocal primary liver cancer; moreover, the ablation effects were compared between tumors of different sizes. Laparoscope-guided needle ablation was conducted on 84 lesions from 32 patients with primary liver cancer based on tumor size, quantity, and location. Moreover, the perioperative data, ablation effects according to tumor size, and long-term follow-up results were analyzed. Among the 84 nodules treated via microwave ablation, tumors measuring ≤ 3 cm demonstrated complete ablation upon imaging analysis conducted 1 month after surgery. Moreover, 5 of the tumors measuring > 3 cm demonstrated incomplete ablation. In these cases, a second procedure was performed, until imaging studies confirmed that complete ablation was achieved. Laparoscopic microwave ablation allows for precise puncture positioning, an effective ablation range, and safe and feasible surgery, which is especially suitable for liver tumors located in sites difficult to access.

  16. Segmentation of arterial vessel wall motion to sub-pixel resolution using M-mode ultrasound.

    Science.gov (United States)

    Fancourt, Craig; Azer, Karim; Ramcharan, Sharmilee L; Bunzel, Michelle; Cambell, Barry R; Sachs, Jeffrey R; Walker, Matthew

    2008-01-01

    We describe a method for segmenting arterial vessel wall motion to sub-pixel resolution, using the returns from M-mode ultrasound. The technique involves measuring the spatial offset between all pairs of scans from their cross-correlation, converting the spatial offsets to relative wall motion through a global optimization, and finally translating from relative to absolute wall motion by interpolation over the M-mode image. The resulting detailed wall distension waveform has the potential to enhance existing vascular biomarkers, such as strain and compliance, as well as enable new ones.

  17. Dual-Modality Imaging of the Human Finger Joint Systems by Using Combined Multispectral Photoacoustic Computed Tomography and Ultrasound Computed Tomography

    Directory of Open Access Journals (Sweden)

    Yubin Liu

    2016-01-01

    Full Text Available We developed a homemade dual-modality imaging system that combines multispectral photoacoustic computed tomography and ultrasound computed tomography for reconstructing the structural and functional information of human finger joint systems. The fused multispectral photoacoustic-ultrasound computed tomography (MPAUCT system was examined by the phantom and in vivo experimental tests. The imaging results indicate that the hard tissues such as the bones and the soft tissues including the blood vessels, the tendon, the skins, and the subcutaneous tissues in the finger joints systems can be effectively recovered by using our multimodality MPAUCT system. The developed MPAUCT system is able to provide us with more comprehensive information of the human finger joints, which shows its potential for characterization and diagnosis of bone or joint diseases.

  18. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    Science.gov (United States)

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  19. A computational study for investigating acoustic streaming and tissue heating during high intensity focused ultrasound through blood vessel with an obstacle

    Science.gov (United States)

    Parvin, Salma; Sultana, Aysha

    2017-06-01

    The influence of High Intensity Focused Ultrasound (HIFU) on the obstacle through blood vessel is studied numerically. A three-dimensional acoustics-thermal-fluid coupling model is employed to compute the temperature field around the obstacle through blood vessel. The model construction is based on the linear Westervelt and conjugate heat transfer equations for the obstacle through blood vessel. The system of equations is solved using Finite Element Method (FEM). We found from this three-dimensional numerical study that the rate of heat transfer is increasing from the obstacle and both the convective cooling and acoustic streaming can considerably change the temperature field.

  20. 3D reconstruction of microvascular flow phantoms with hybrid imaging modalities

    Science.gov (United States)

    Lin, Jingying; Hsiung, Kevin; Ritenour, Russell; Golzarian, Jafar

    2011-03-01

    Microvascular flow phantoms were built to aid the development of a hemodynamic simulation model for treating hepatocelluar carcinoma. The goal is to predict the blood flow routing for embolotherapy planning. Embolization is to deliver agents (e.g. microspheres) to the vicinity of the tumor to obstruct blood supply and nutrients to the tumor, targeting into 30 - 40 μm arterioles. Due to the size of the catheter, it has to release microspheres at an upper stream location, which may not localize the blocking effect. Accurate anatomical descriptions of microvasculature will help to conduct a reliable simulation and prepare a successful embolization strategy. Modern imaging devices can generate 3D reconstructions with ease. However, with a fixed detector size, larger field of view yields lower resolution. Clinical CT images can't be used to measure micro vessel dimensions, while micro-CT requires more acquisitions to reconstruct larger vessels. A multi-tiered, montage 3D reconstruction method with hybrid-modality imagery is devised to minimize the reconstruction effort. Regular CT is used for larger vessels and micro-CT is used for micro vessels. The montage approach aims to stitch up images with different resolutions and orientations. A resolution-adaptable 3D image registration is developed to assemble the images. We have created vessel phantoms that consist of several tiers of bifurcating polymer tubes in reducing diameters, down to 25 μm. No previous work of physical flow phantom has ventured into this small scale. Overlapping phantom images acquired from clinical CT and micro-CT are used to verify the image registration fidelity.

  1. Integrated ultrasound and magnetic resonance imaging for simultaneous temperature and cavitation monitoring during focused ultrasound therapies.

    Science.gov (United States)

    Arvanitis, Costas D; McDannold, Nathan

    2013-11-01

    Ultrasound can be used to noninvasively produce different bioeffects via viscous heating, acoustic cavitation, or their combination, and these effects can be exploited to develop a wide range of therapies for cancer and other disorders. In order to accurately localize and control these different effects, imaging methods are desired that can map both temperature changes and cavitation activity. To address these needs, the authors integrated an ultrasound imaging array into an MRI-guided focused ultrasound (MRgFUS) system to simultaneously visualize thermal and mechanical effects via passive acoustic mapping (PAM) and MR temperature imaging (MRTI), respectively. The system was tested with an MRgFUS system developed for transcranial sonication for brain tumor ablation in experiments with a tissue mimicking phantom and a phantom-filled ex vivo macaque skull. In experiments on cavitation-enhanced heating, 10 s continuous wave sonications were applied at increasing power levels (30-110 W) until broadband acoustic emissions (a signature for inertial cavitation) were evident. The presence or lack of signal in the PAM, as well as its magnitude and location, were compared to the focal heating in the MRTI. Additional experiments compared PAM with standard B-mode ultrasound imaging and tested the feasibility of the system to map cavitation activity produced during low-power (5 W) burst sonications in a channel filled with a microbubble ultrasound contrast agent. When inertial cavitation was evident, localized activity was present in PAM and a marked increase in heating was observed in MRTI. The location of the cavitation activity and heating agreed on average after registration of the two imaging modalities; the distance between the maximum cavitation activity and focal heating was -3.4 ± 2.1 mm and -0.1 ± 3.3 mm in the axial and transverse ultrasound array directions, respectively. Distortions and other MRI issues introduced small uncertainties in the PAM

  2. Comparison between ultrasound guided technique and digital palpation technique for radial artery cannulation in adult patients: An updated meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Bhattacharjee, Sulagna; Maitra, Souvik; Baidya, Dalim K

    2018-03-22

    Possible advantages and risks associated with ultrasound guided radial artery cannulation in-comparison to digital palpation guided method in adult patients are not fully known. We have compared ultrasound guided radial artery cannulation with digital palpation technique in this meta-analysis. Meta-analysis of randomized controlled trials. Trials conducted in operating room, emergency department, cardiac catheterization laboratory. PubMed and Cochrane Central Register of Controlled Trials (CENTRAL) were searched (from 1946 to 20th November 2017) to identify prospective randomized controlled trials in adult patients. Two-dimensional ultrasound guided radial artery catheterization versus digital palpation guided radial artery cannulation. Overall cannulation success rate, first attempt success rate, time to cannulation and mean number of attempts to successful cannulation. Odds ratio (OR) and standardized mean difference (SMD) or mean difference (MD) with 95% confidence interval (CI) were calculated for categorical and continuous variables respectively. Data of 1895 patients from 10 studies have been included in this meta- analysis. Overall cannulation success rate was similar between ultrasound guided technique and digital palpation [OR (95% CI) 2.01 (1.00, 4.06); p = 0.05]. Ultrasound guided radial artery cannulation is associated with higher first attempt success rate of radial artery cannulation in comparison to digital palpation [OR (95% CI) 2.76 (186, 4.10); p guided technique with palpation technique. Radial artery cannulation by ultrasound guidance may increase the first attempt success rate but not the overall cannulation success when compared to digital palpation technique. However, results of this meta-analysis should be interpreted with caution due presence of heterogeneity. Copyright © 2018. Published by Elsevier Inc.

  3. Guided interventions in musculoskeletal ultrasound: what's the evidence?

    Energy Technology Data Exchange (ETDEWEB)

    Davidson, J., E-mail: jdavidson@doctors.org.u [St Richard' s Hospital, Spitalfield Lane, Chichester, West Sussex (United Kingdom); Jayaraman, S. [St Richard' s Hospital, Spitalfield Lane, Chichester, West Sussex (United Kingdom)

    2011-02-15

    Increasing histological and radiological understanding of the processes involved in soft-tissue injury is leading to novel targeted treatments. A number of reviews have recommended that these treatments should be performed with image guidance. This review describes current ultrasound-guided interventions and injections, together with the level of evidence for these. Discussion of guided interventions will include; percutaneous lavage (barbotage), brisement, dry needling, electrocoagulation, and of guided injections; corticosteroids, autologous substances (blood and platelet rich plasma), sclerosants, and prolotherapy (hyperosmolar dextrose). Representative imaging illustrating some of these techniques is included for correlation with the methods described. As these procedures are often performed in sportspeople, it is essential that the radiologist is aware of prohibited substances and methods outlined in an annual publication from the World Anti-Doping Association (WADA). Finally, future directions, including the use of autologous substances, mesenchymal and stem cells will be discussed.

  4. Noncontact ultrasound imaging applied to cortical bone phantoms

    OpenAIRE

    Bulman, J. B.; Ganezer, K. S.; Halcrow, P. W.; Neeson, Ian

    2012-01-01

    Purpose: The purpose of this paper was to take the first steps toward applying noncontact ultrasound (NCU) to the tasks of monitoring osteoporosis and quantitative ultrasound imaging (QUS) of cortical bone. The authors also focused on the advantages of NCU, such as its lack of reliance on a technologist to apply transducers and a layer of acoustical coupling gel, the ability of the transducers to operate autonomously as specified by preprogrammed software, and the likely reduction in statisti...

  5. Interventional ultrasound

    International Nuclear Information System (INIS)

    VanSonnenberg, E.

    1987-01-01

    This book contains 12 chapters and several case studies. Some of the chapter titles are: The Interplay of Ultrasound and Computed Tomography in the Planning and Execution of Interventional Procedures: Ulltrasound Guided Biopsy; Interventioal Genitourinary Sonography; Diagnosis and Treatment of Pericardial Effusion Using Ultrasonic Guidance; and New Ultrasound-Guided Interventional Procedures--Cholecystostomy, Pancreatography, Gastrostomy

  6. Evaluation of motion measurement using cine MRI for image guided stereotactic body radiotherapy on a new phantom platform

    Science.gov (United States)

    Cai, Jing; Wang, Ziheng; Yin, Fang-Fang

    2011-01-01

    The objective of this study is to investigate accuracy of motion tracking of cine magnetic resonance imaging (MRI) for image-guided stereotactic body radiotherapy. A phantom platform was developed in this work to fulfill the goal. The motion phantom consisted of a platform, a solid thread, a motor and a control system that can simulate motion in various modes. To validate its reproducibility, the phantom platform was setup three times and imaged with fluoroscopy using an electronic portal imaging device (EPID) for the same motion profile. After the validation test, the phantom platform was evaluated using cine MRI at 2.5 frames/second on a 1.5T GE scanner using five different artificial profiles and five patient profiles. The above profiles were again measured with EPID fluoroscopy and used as references. Discrepancies between measured profiles from cine MRI and EPID were quantified using root-mean-square (RMS) and standard deviation (SD). Pearson’s product moment correlational analysis was used to test correlation. The standard deviation for the reproducibility test was 0.28 mm. The discrepancies (RMS) between all profiles measured by cine MRI and EPID fluoroscopy ranged from 0.30 to 0.49 mm for artificial profiles and ranged from 0.75 to 0.91 mm for five patient profiles. The cine MRI sequence could precisely track phantom motion and the proposed motion phantom was feasible to evaluate cine MRI accuracy. PMID:29296304

  7. A multimodal instrument for real-time in situ study of ultrasound and cavitation mediated drug delivery.

    Science.gov (United States)

    Bian, Shuning; Seth, Anjali; Daly, Dan; Carlisle, Robert; Stride, Eleanor

    2017-03-01

    The development of a multimodal instrument capable of real-time in situ measurements of cavitation activity and effect in tissue mimicking phantoms during ultrasound and cavitation mediated drug delivery experiments is described here. The instrument features an acoustic arm that can expose phantoms to high-intensity focused-ultrasound while measuring cavitation activity and an optical arm that monitors cavitation effect using confocal microscopy. This combination of modalities allows real-time in situ characterisation of drug delivery in tissue and tissue mimicking phantoms during ultrasound and cavitation mediated drug delivery experiments. A representative result, obtained with a tissue mimicking phantom and acoustically activated droplets, is presented here as a demonstration of the instrument's capabilities and potential applications.

  8. SU-F-J-176: Development of a Patient-Specific 3D Couplant Pad for Ultrasound IGRT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, H; Chang, A [Soonchunhyang University Hospital, Seoul (Korea, Republic of); Ye, S [Seoul National University, Seoul (Korea, Republic of)

    2016-06-15

    Purpose: to overcome the several issues of ultrasound image-guided radiation therapy (US IGRT) such as probe pressure and optical tracking disability by using a patient-specific three-dimensional couplant pad (CP) fabricated by a patient’s skin mold using a 3D printing technique. Methods: A CP was then fabricated by pouring gelatin solution into a fixed-shape container accommodating the patient skin mold fabricated by a 3D printer. A breast phantom was fabricated with the compound of gelatin and agarose and a phantom study was carried out. From four patients who underwent US IGRT, total 486 ultrasound images with and without a CP were acquired before treatment. Effectiveness of the use of the CP was evaluated. Results: The positioning accuracies in the phantom study were 0.9 ± 0.3 mm and 1.3 ± 0.4 mm with and without the CP in 3D vector amplitude, respectively. In the patient study, the use of CP reduced the mean target shift from 4.7 mm to 3.7 mm in 3D vector amplitude and the one standard deviation from 2.2 mm to 1.7 mm. It also improved the image contrast around the treatment target by 10 %. The centroid offset of the target volume affected from the US scanning coverage and the target deformation due to the excessive probe pressure was decreased from 4.4 mm to 2.9 mm due to the use of CP. Its difference among three different users was statistically significant (p=0.020) without the use of CP but not significantly different (p=0.133) with the use of CP. Conclusion: Our patient-specific 3D CP using a mold by 3D printing technique is a promising strategy for improving tracking accuracy, image quality, and inter-observer variation for ultrasound-based image guided radiotherapy. In addition to its conventional advantage of non-invasiveness, US can be more facilitated in radiotherapy by the developed CP.

  9. SU-F-J-176: Development of a Patient-Specific 3D Couplant Pad for Ultrasound IGRT

    International Nuclear Information System (INIS)

    Kim, H; Chang, A; Ye, S

    2016-01-01

    Purpose: to overcome the several issues of ultrasound image-guided radiation therapy (US IGRT) such as probe pressure and optical tracking disability by using a patient-specific three-dimensional couplant pad (CP) fabricated by a patient’s skin mold using a 3D printing technique. Methods: A CP was then fabricated by pouring gelatin solution into a fixed-shape container accommodating the patient skin mold fabricated by a 3D printer. A breast phantom was fabricated with the compound of gelatin and agarose and a phantom study was carried out. From four patients who underwent US IGRT, total 486 ultrasound images with and without a CP were acquired before treatment. Effectiveness of the use of the CP was evaluated. Results: The positioning accuracies in the phantom study were 0.9 ± 0.3 mm and 1.3 ± 0.4 mm with and without the CP in 3D vector amplitude, respectively. In the patient study, the use of CP reduced the mean target shift from 4.7 mm to 3.7 mm in 3D vector amplitude and the one standard deviation from 2.2 mm to 1.7 mm. It also improved the image contrast around the treatment target by 10 %. The centroid offset of the target volume affected from the US scanning coverage and the target deformation due to the excessive probe pressure was decreased from 4.4 mm to 2.9 mm due to the use of CP. Its difference among three different users was statistically significant (p=0.020) without the use of CP but not significantly different (p=0.133) with the use of CP. Conclusion: Our patient-specific 3D CP using a mold by 3D printing technique is a promising strategy for improving tracking accuracy, image quality, and inter-observer variation for ultrasound-based image guided radiotherapy. In addition to its conventional advantage of non-invasiveness, US can be more facilitated in radiotherapy by the developed CP.

  10. Update on the role of ultrasound guided radiofrequency ablation for thyroid nodule treatment

    DEFF Research Database (Denmark)

    Radzina, Maija; Cantisani, Vito; Rauda, Madara

    2017-01-01

    Thyroid nodules can be frequently detected in general population, most of them are benign, however malignant cases are rising in the past decades. Ultrasound (US) is the most common imaging modality to assess thyroid nodular lesions, plan patient work-up and guide minimally invasive treatment...

  11. Contrast generation in the nuclear-spin tomography by pulsed ultrasound

    International Nuclear Information System (INIS)

    Oehms, Ole Benjamin

    2009-01-01

    In the framework of this thesis a combined method of ultrasound and nuclear-spin tomography is presented. Via ultrasound pulses by the sound-radiation force in liquids and tissue phantoms motions are generated, which depend on ther viscoelastic properties. This motions are made visible by a motion-sensitive tomograph sequence in the phase image of the tomograph in form of a phase change. The first measurements on simple phantoms and liquids are presented. [de

  12. pH/Ultrasound Dual-Responsive Gas Generator for Ultrasound Imaging-Guided Therapeutic Inertial Cavitation and Sonodynamic Therapy.

    Science.gov (United States)

    Feng, Qianhua; Zhang, Wanxia; Yang, Xuemei; Li, Yuzhen; Hao, Yongwei; Zhang, Hongling; Hou, Lin; Zhang, Zhenzhong

    2018-03-01

    Herein, a pH/ultrasound dual-responsive gas generator is reported, which is based on mesoporous calcium carbonate (MCC) nanoparticles by loading sonosensitizer (hematoporphyrin monomethyl ether (HMME)) and modifying surface hyaluronic acid (HA). After pinpointing tumor regions with prominent targeting efficiency, HMME/MCC-HA decomposes instantaneously under the cotriggering of tumoral inherent acidic condition and ultrasound (US) irradiation, concurrently accompanying with CO 2 generation and HMME release with spatial/temporal resolution. Afterward, the CO 2 bubbling and bursting effect under US stimulus results in cavitation-mediated irreversible cell necrosis, as well as the blood vessel destruction to further occlude the blood supply, providing a "bystander effect." Meanwhile, reactive oxygen species generated from HMME can target the apoptotic pathways for effective sonodynamic therapy. Thus, the combination of apoptosis/necrosis with multimechanisms consequently results in a remarkable antitumor therapeutic efficacy, simultaneously minimizing the side effects on major organs. Moreover, the echogenic property of CO 2 make the nanoplatform as a powerful ultrasound contrast agent to identify cancerous lesions. Based on the above findings, such all-in-one drug delivery platform of HMME/MCC-HA is utilized to provide the US imaging guidance for therapeutic inertial cavitation and sonodynamic therapy simultaneously, which highlights possibilities of advancing cancer theranostics in biomedical fields. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. The Usefulness of Intensivist-Performed Bedside Drainage of Pleural Effusion via Ultrasound-Guided Pigtail Catheter

    Directory of Open Access Journals (Sweden)

    Joo Won Min

    2014-08-01

    CONCLUSIONS: Intensivist-performed bedside drainage of pleural effusion via ultrasound (US-guided pigtail catheter is useful and safe and may be recommended in some patients in an intensive care unit.

  14. Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields.

    Science.gov (United States)

    Ben Daya, Ibrahim; Chen, Albert I H; Shafiee, Mohammad Javad; Wong, Alexander; Yeow, John T W

    2017-09-06

    The row-column method received a lot of attention for 3-D ultrasound imaging. By reducing the number of connections required to address the 2-D array and therefore reducing the amount of data to handle, this addressing method allows for real time 3-D imaging. Row-column still has its limitations: the issues of sparsity, speckle noise inherent to ultrasound, the spatially varying point spread function, and the ghosting artifacts inherent to the row-column method must all be taken into account when building a reconstruction framework. In this research, we build on a previously published system and propose an edge-guided, compensated row-column ultrasound imaging system that incorporates multilayered edge-guided stochastically fully connected conditional random fields to address the limitations of the row-column method. Tests carried out on simulated and real row-column ultrasound images show the effectiveness of our proposed system over other published systems. Visual assessment show our proposed system's potential at preserving edges and reducing speckle. Quantitative analysis shows that our proposed system outperforms previously published systems when evaluated with metrics such as Peak Signal-to-Noise Ratio, Coefficient of Correlation, and Effective Number of Looks. These results show the potential of our proposed system as an effective tool for enhancing 3-D row-column imaging.

  15. Ultrasound-guided transversus abdominis plane (TAP) block: a useful adjunct in the management of postoperative respiratory failure.

    Science.gov (United States)

    Singh, Mandeep; Chin, Ki Jinn; Chan, Vincent

    2011-06-01

    The ultrasound-guided transversus abdominis plane (TAP) block is a useful tool in controlling postoperative pain following abdominal surgery. The bilateral ultrasound-guided TAP blocks successfully managed the pain of a patient presenting with hypoxemia and respiratory failure in the Post-anesthesia Care Unit, following a laparotomy for small bowel obstruction during general anesthesia. The TAP block reduced systemic opioid requirements and opioid-induced sedation and respiratory depression, improved patient compliance with non-invasive positive pressure ventilation, and prevented the need for intubation and ventilation in the intensive care unit. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Ultrasound-guided image fusion with computed tomography and magnetic resonance imaging. Clinical utility for imaging and interventional diagnostics of hepatic lesions

    International Nuclear Information System (INIS)

    Clevert, D.A.; Helck, A.; Paprottka, P.M.; Trumm, C.; Reiser, M.F.; Zengel, P.

    2012-01-01

    Abdominal ultrasound is often the first-line imaging modality for assessing focal liver lesions. Due to various new ultrasound techniques, such as image fusion, global positioning system (GPS) tracking and needle tracking guided biopsy, abdominal ultrasound now has great potential regarding detection, characterization and treatment of focal liver lesions. Furthermore, these new techniques will help to improve the clinical management of patients before and during interventional procedures. This article presents the principle and clinical impact of recently developed techniques in the field of ultrasound, e.g. image fusion, GPS tracking and needle tracking guided biopsy and discusses the results based on a feasibility study on 20 patients with focal hepatic lesions. (orig.) [de

  17. A tool for validating MRI-guided strategies: a digital breathing CT/MRI phantom of the abdominal site.

    Science.gov (United States)

    Paganelli, Chiara; Summers, Paul; Gianoli, Chiara; Bellomi, Massimo; Baroni, Guido; Riboldi, Marco

    2017-11-01

    Dynamic magnetic resonance imaging (MRI) is emerging as the elected image modality for organ motion quantification and management in image-guided radiotherapy. However, the lack of validation tools is an open issue for image guidance in the abdominal and thoracic organs affected by organ motion due to respiration. We therefore present an abdominal four-dimensional (4D) CT/MRI digital phantom, including the estimation of MR tissue parameters, simulation of dedicated abdominal MR sequences, modeling of radiofrequency coil response and noise, followed by k-space sampling and image reconstruction. The phantom allows the realistic simulation of images generated by MR pulse sequences with control of scan and tissue parameters, combined with co-registered CT images. In order to demonstrate the potential of the phantom in a clinical scenario, we describe the validation of a virtual T1-weighted 4D MRI strategy. Specifically, the motion extracted from a T2-weighted 4D MRI is used to warp a T1-weighted breath-hold acquisition, with the aim of overcoming trade-offs that limit T1-weighted acquisitions. Such an application shows the applicability of the digital CT/MRI phantom as a validation tool, which should be especially useful for cases unsuited to obtain real imaging data.

  18. A dual-mode hemispherical sparse array for 3D passive acoustic mapping and skull localization within a clinical MRI guided focused ultrasound device

    Science.gov (United States)

    Crake, Calum; Brinker, Spencer T.; Coviello, Christian M.; Livingstone, Margaret S.; McDannold, Nathan J.

    2018-03-01

    Previous work has demonstrated that passive acoustic imaging may be used alongside MRI for monitoring of focused ultrasound therapy. However, past implementations have generally made use of either linear arrays originally designed for diagnostic imaging or custom narrowband arrays specific to in-house therapeutic transducer designs, neither of which is fully compatible with clinical MR-guided focused ultrasound (MRgFUS) devices. Here we have designed an array which is suitable for use within an FDA-approved MR-guided transcranial focused ultrasound device, within the bore of a 3 Tesla clinical MRI scanner. The array is constructed from 5  ×  0.4 mm piezoceramic disc elements arranged in pseudorandom fashion on a low-profile laser-cut acrylic frame designed to fit between the therapeutic elements of a 230 kHz InSightec ExAblate 4000 transducer. By exploiting thickness and radial resonance modes of the piezo discs the array is capable of both B-mode imaging at 5 MHz for skull localization, as well as passive reception at the second harmonic of the therapy array for detection of cavitation and 3D passive acoustic imaging. In active mode, the array was able to perform B-mode imaging of a human skull, showing the outer skull surface with good qualitative agreement with MR imaging. Extension to 3D showed the array was able to locate the skull within  ±2 mm/2° of reference points derived from MRI, which could potentially allow registration of a patient to the therapy system without the expense of real-time MRI. In passive mode, the array was able to resolve a point source in 3D within a  ±10 mm region about each axis from the focus, detect cavitation (SNR ~ 12 dB) at burst lengths from 10 cycles to continuous wave, and produce 3D acoustic maps in a flow phantom. Finally, the array was used to detect and map cavitation associated with microbubble activity in the brain in nonhuman primates.

  19. Diagnostic efficacy of ultrasound-guided core-needle biopsy of peripheral lymph nodes in sarcoidosis.

    Science.gov (United States)

    Boussouar, S; Medjhoul, A; Bernaudin, J F; Tayebjee, O; Soussan, M; Uzunhan, Y; Nunes, H; Kambouchner, M; Martin, A; Valeyre, D; Brillet, P Y

    2015-09-14

    Core-needle biopsy guided by ultrasound can be performed for investigating peripheral lymph node (PLN). The aim of this study was to determine the efficacy of this technique in sarcoidosis. Retrospective review of files of all patients in the database of the radiology department of Avicenne university hospital who underwent PLN biopsies guided by ultrasound from January 2008 to June 2011 (n=292). Cases with either granulomas at histology with the procedure or with a final diagnosis of sarcoidosis were included in the study. The histological specimens were adequate in 282 out of 292 cases (96%) showing non-caseating granulomas in 22 cases (n=20 patients with a final diagnosis of sarcoidosis and n=2 patients with tuberculosis). After reviewing clinical files of the 282 patient, 22 were confirmed to have sarcoidosis, at initial presentation (n=19) or later during flare-up or relapse (n=3) with only 2 patients having no granuloma on PLN biopsy. PLN were palpable in 18 cases and only detected by (18F)FDG-PET/CT showing increased PLN uptake in 4 cases. The sensitivity and specificity of adequate biopsy were 91 and 99% and the positive and negative predictive values were 91 and 99%, respectively. Core-needle biopsy guided by ultrasound has a high efficacy for evidencing granulomas in sarcoidosis patients with PLN involvement either clinically palpable or in the presence of (18F)FDG-PET/CT uptake.

  20. Comparative study between ultrasound guided TAP block and paravertebral block in upper abdominal surgeries

    Directory of Open Access Journals (Sweden)

    Ruqaya M Elsayed Goda

    2017-01-01

    Conclusion: We concluded that ultrasound guided transverses abdominis plane block and thoracic paravertebral block were safe and effective anesthetic technique for upper abdominal surgery with longer and potent postoperative analgesia in thoracic paravertebral block than transverses abdominis block.

  1. Detection of the Single-Session Complete Ablation Rate by Contrast-Enhanced Ultrasound during Ultrasound-Guided Laser Ablation for Benign Thyroid Nodules: A Prospective Study

    Directory of Open Access Journals (Sweden)

    Shuhua Ma

    2016-01-01

    Full Text Available This study aimed to investigate the single-session complete ablation rate of ultrasound-guided percutaneous laser ablation (LA for benign thyroid nodules. LA was performed in 90 patients with 118 benign thyroid nodules. Contrast-enhanced ultrasound (CEUS was used to evaluate complete nodule ablation one day after ablation. Thyroid nodule volumes, thyroid functions, clinical symptoms and complications were evaluated 1, 3, 6, 12, and 18 months after ablation. Results showed that all benign thyroid nodules successfully underwent LA. The single-session complete ablation rates for nodules with maximum diameters ≤2 cm, 2-3 cm and ≥3 cm were 93.4%, 70.3% and 61.1%, respectively. All nodule volumes significantly decreased than that one day after ablation (P0.05. Three patients had obvious pain during ablation; one (1.1% had recurrent laryngeal nerve injury, but the voice returned to normal within 6 months after treatment. Thus, ultrasound-guided LA can effectively inactivate benign thyroid nodules. LA is a potentially viable minimally invasive treatment that offers good cosmetic effects.

  2. MO-FG-CAMPUS-JeP3-04: Feasibility Study of Real-Time Ultrasound Monitoring for Abdominal Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Su, Lin; Kien Ng, Sook; Zhang, Ying; Herman, Joseph; Wong, John; Ding, Kai [Department of Radiation Oncology, John Hopkins University, Baltimore, MD (United States); Ji, Tianlong [Department of Radiation Oncology, The First Hospital of China Medical University, Shenyang, Liaoning (China); Iordachita, Iulian [Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD (United States); Tutkun Sen, H.; Kazanzides, Peter; Lediju Bell, Muyinatu A. [Department of Computer Science, Johns Hopkins University, Baltimore, MD (United States)

    2016-06-15

    Purpose: Ultrasound is ideal for real-time monitoring in radiotherapy with high soft tissue contrast, non-ionization, portability, and cost effectiveness. Few studies investigated clinical application of real-time ultrasound monitoring for abdominal stereotactic body radiation therapy (SBRT). This study aims to demonstrate the feasibility of real-time monitoring of 3D target motion using 4D ultrasound. Methods: An ultrasound probe holding system was designed to allow clinician to freely move and lock ultrasound probe. For phantom study, an abdominal ultrasound phantom was secured on a 2D programmable respiratory motion stage. One side of the stage was elevated than another side to generate 3D motion. The motion stage made periodic breath-hold movement. Phantom movement tracked by infrared camera was considered as ground truth. For volunteer study three healthy subjects underwent the same setup for abdominal SBRT with active breath control (ABC). 4D ultrasound B-mode images were acquired for both phantom and volunteers for real-time monitoring. 10 breath-hold cycles were monitored for each experiment. For phantom, the target motion tracked by ultrasound was compared with motion tracked by infrared camera. For healthy volunteers, the reproducibility of ABC breath-hold was evaluated. Results: Volunteer study showed the ultrasound system fitted well to the clinical SBRT setup. The reproducibility for 10 breath-holds is less than 2 mm in three directions for all three volunteers. For phantom study the motion between inspiration and expiration captured by camera (ground truth) is 2.35±0.02 mm, 1.28±0.04 mm, 8.85±0.03 mm in LR, AP, SI directly, respectively. The motion monitored by ultrasound is 2.21±0.07 mm, 1.32±0.12mm, 9.10±0.08mm, respectively. The motion monitoring error in any direction is less than 0.5 mm. Conclusion: The volunteer study proved the clinical feasibility of real-time ultrasound monitoring for abdominal SBRT. The phantom and volunteer ABC

  3. MO-FG-CAMPUS-JeP3-04: Feasibility Study of Real-Time Ultrasound Monitoring for Abdominal Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Su, Lin; Kien Ng, Sook; Zhang, Ying; Herman, Joseph; Wong, John; Ding, Kai; Ji, Tianlong; Iordachita, Iulian; Tutkun Sen, H.; Kazanzides, Peter; Lediju Bell, Muyinatu A.

    2016-01-01

    Purpose: Ultrasound is ideal for real-time monitoring in radiotherapy with high soft tissue contrast, non-ionization, portability, and cost effectiveness. Few studies investigated clinical application of real-time ultrasound monitoring for abdominal stereotactic body radiation therapy (SBRT). This study aims to demonstrate the feasibility of real-time monitoring of 3D target motion using 4D ultrasound. Methods: An ultrasound probe holding system was designed to allow clinician to freely move and lock ultrasound probe. For phantom study, an abdominal ultrasound phantom was secured on a 2D programmable respiratory motion stage. One side of the stage was elevated than another side to generate 3D motion. The motion stage made periodic breath-hold movement. Phantom movement tracked by infrared camera was considered as ground truth. For volunteer study three healthy subjects underwent the same setup for abdominal SBRT with active breath control (ABC). 4D ultrasound B-mode images were acquired for both phantom and volunteers for real-time monitoring. 10 breath-hold cycles were monitored for each experiment. For phantom, the target motion tracked by ultrasound was compared with motion tracked by infrared camera. For healthy volunteers, the reproducibility of ABC breath-hold was evaluated. Results: Volunteer study showed the ultrasound system fitted well to the clinical SBRT setup. The reproducibility for 10 breath-holds is less than 2 mm in three directions for all three volunteers. For phantom study the motion between inspiration and expiration captured by camera (ground truth) is 2.35±0.02 mm, 1.28±0.04 mm, 8.85±0.03 mm in LR, AP, SI directly, respectively. The motion monitored by ultrasound is 2.21±0.07 mm, 1.32±0.12mm, 9.10±0.08mm, respectively. The motion monitoring error in any direction is less than 0.5 mm. Conclusion: The volunteer study proved the clinical feasibility of real-time ultrasound monitoring for abdominal SBRT. The phantom and volunteer ABC

  4. Efficacy of a single ultrasound-guided injection for the treatment of hip osteoarthritis.

    LENUS (Irish Health Repository)

    Atchia, Ismaël

    2011-01-01

    Intra-articular injection is effective for osteoarthritis, but the best single injection strategy is not known, nor are there established predictors of response. The objectives of this study were to assess and predict response to a single ultrasound-guided injection in moderate to severe hip osteoarthritis.

  5. MRI monitoring of focused ultrasound sonications near metallic hardware.

    Science.gov (United States)

    Weber, Hans; Ghanouni, Pejman; Pascal-Tenorio, Aurea; Pauly, Kim Butts; Hargreaves, Brian A

    2018-07-01

    To explore the temperature-induced signal change in two-dimensional multi-spectral imaging (2DMSI) for fast thermometry near metallic hardware to enable MR-guided focused ultrasound surgery (MRgFUS) in patients with implanted metallic hardware. 2DMSI was optimized for temperature sensitivity and applied to monitor focus ultrasound surgery (FUS) sonications near metallic hardware in phantoms and ex vivo porcine muscle tissue. Further, we evaluated its temperature sensitivity for in vivo muscle in patients without metallic hardware. In addition, we performed a comparison of temperature sensitivity between 2DMSI and conventional proton-resonance-frequency-shift (PRFS) thermometry at different distances from metal devices and different signal-to-noise ratios (SNR). 2DMSI thermometry enabled visualization of short ultrasound sonications near metallic hardware. Calibration using in vivo muscle yielded a constant temperature sensitivity for temperatures below 43 °C. For an off-resonance coverage of ± 6 kHz, we achieved a temperature sensitivity of 1.45%/K, resulting in a minimum detectable temperature change of ∼2.5 K for an SNR of 100 with a temporal resolution of 6 s per frame. The proposed 2DMSI thermometry has the potential to allow MR-guided FUS treatments of patients with metallic hardware and therefore expand its reach to a larger patient population. Magn Reson Med 80:259-271, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  6. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun [Seoul Red Cross Hospital, Seoul (Korea, Republic of)

    1993-05-15

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer.

  7. The diagnostic value of ultrasound-guided fine-needle aspiration biopsy in breast masses

    International Nuclear Information System (INIS)

    Lee, Nam Hee; Lim, Hyun Yang; Park, Noh Kyong; Tae, Seok; Shin, Kyung Ja; Lee, Sang Chun

    1993-01-01

    Real-time ultrasound-guided fine-needle aspiration biopsy in 137 solid breast masses was performed. Sonographic findings were categorized into three groups and aspirates were categorized into three cytologic groups. The cytologic results was reported benign masses (cytologic group 1) in 71 cases (52%). malignant masses (cytologic group 2 and 3) in 44 cases (32%) and insufficient specimens in 22 case (16%). Insufficient specimens were treated as benign masses. Excisional biopsy in 44 malignant masses and 3 benign masses according to cytologic results, clinical findings and follow up study was performed. The result was reported 41 malignant masses and 6 benign masses. Based on cytologic criteria, sensitivity for detection of malignancy was 93% and specificity was 94%. In conclusion, the high specificity provided by ultrasound-guided fine-needle aspiration biopsy could markedly reduce unnecessary surgical excisions for benign masses and it should be routinely performed, since it can give physical and emotional benefits to patients and lead to earlier and cost effective diagnosis of breast cancer

  8. Feasibility and safety of ultrasound-guided nerve block for management of limb injuries by emergency care physicians

    Directory of Open Access Journals (Sweden)

    Sanjeev Bhoi

    2012-01-01

    Full Text Available Background: Patients require procedural sedation and analgesia (PSA for the treatment of acute traumatic injuries. PSA has complications. Ultrasound (US guided peripheral nerve block is a safe alternative. Aim: Ultrasound guided nerve blocks for management of traumatic limb emergencies in Emergency Department (ED. Setting and Design: Prospective observational study conducted in ED. Materials and Methods: Patients above five years requiring analgesia for management of limb emergencies were recruited. Emergency Physicians trained in US guided nerve blocks performed the procedure. Statistical analysis: Effectiveness of pain control, using visual analogue scale was assessed at baseline and at 15 and 60 minutes after the procedure. Paired t test was used for comparison. Results: Fifty US guided nerve blocks were sciatic- 4 (8%, femoral-7 (14%, brachial- 29 (58%, median -6 (12%, and radial 2 (4% nerves. No patients required rescue PSA. Initial median VAS score was 9 (Inter Quartile Range [IQR] 7-10 and at 1 hour was 2(IQR 0-4. Median reduction in VAS score was 7.44 (IQR 8-10(75%, 1-2(25% (P=0.0001. Median procedure time was 9 minutes (IQR 3, 12 minutes and median time to reduction of pain was 5 minutes (IQR 1,15 minutes. No immediate or late complications noticed at 3 months. Conclusion: Ultrasound-guided nerve blocks can be safely and effectively performed for upper and lower limb emergencies by emergency physicians with adequate training.

  9. Ultrasound-guided epidural anesthesia for a parturient with severe malformations of the skeletal system undergoing cesarean delivery: a case report

    Directory of Open Access Journals (Sweden)

    Luo LL

    2015-05-01

    Full Text Available LinLi Luo,* Juan Ni,* Lan Wu, Dong Luo Department of Anesthesiology, West China Second Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China  *These authors contributed equally to this work and should be considered co-first authors Abstract: Anesthetic management of patients with preexisting diseases is challenging and individualized approaches need to be determined based on patients' complications. We report here a case of ultrasound-guided epidural anesthesia in combination with low-dose ketamine during cesarean delivery on a parturient with severe malformations of the skeletal system and airway problems. The ultrasound-guided epidural anesthesia was performed in the L1–L2 space, followed by an intravenous administration of ketamine (0.5 mg/kg for sedation and analgesia. Satisfactory anesthesia was provided to the patient and spontaneous ventilation was maintained during the surgery. The mother and the baby were discharged 5 days after surgery, no complications were reported for either of them. Our work demonstrated that an ultrasound-guided epidural anesthesia combined with low-dose ketamine can be used to successfully maintain spontaneous ventilation and provide effective analgesia during surgery and reduce the risk of postoperative anesthesia-related pulmonary infection. Keywords: anesthesia, regional, cesarean delivery, ketamine, ultrasound-guided

  10. Cost-Effectiveness Comparison of Imaging-Guided Prostate Biopsy Techniques: Systematic Transrectal Ultrasound, Direct In-Bore MRI, and Image Fusion

    NARCIS (Netherlands)

    Venderink, W.; Govers, T.M.; Rooij, M. de; Futterer, J.J.; Sedelaar, J.P.M.

    2017-01-01

    OBJECTIVE: Three commonly used prostate biopsy approaches are systematic transrectal ultrasound guided, direct in-bore MRI guided, and image fusion guided. The aim of this study was to calculate which strategy is most cost-effective. MATERIALS AND METHODS: A decision tree and Markov model were

  11. Engineering analysis of ITER In-Vessel Viewing System guide tube

    Energy Technology Data Exchange (ETDEWEB)

    Casal, Natalia, E-mail: natalia.casal@iter.org [ITER Organization, Route de Vinon sur Verdon, St Paul-lez-Durance (France); Bates, Philip [Fusion for Energy, Barcelona (Spain); Bede, Ottó [Oxford Technologies Ltd., Abingdon (United Kingdom); Damiani, Carlo; Dubus, Gregory [Fusion for Energy, Barcelona (Spain); Omran, Hassan [Oxford Technologies Ltd., Abingdon (United Kingdom); Palmer, Jim [ITER Organization, Route de Vinon sur Verdon, St Paul-lez-Durance (France); Puiu, Adrian [Fusion for Energy, Barcelona (Spain); Reichle, Roger; Suárez, Alejandro; Walker, Christopher; Walsh, Michael [ITER Organization, Route de Vinon sur Verdon, St Paul-lez-Durance (France)

    2015-10-15

    Highlights: • Conceptual design of IVVS Loads action on IVVS Dominant loads. • Seismic and baking conditions. • No active cooling needed for IVVS. • IVVS requires additional support points to avoid excessive deformation. - Abstract: The In Vessel Viewing System (IVVS) will be one of the essential machine diagnostic systems at ITER to provide information about the status of in-vessel and plasma facing components and to evaluate the dust inside the Vacuum Vessel. The current design consists of six scanning probes and their deployment systems, which are placed in dedicated ports at the divertor level. These units are located in resident guiding tubes 10 m long, which allow the IVVS probes to go from their storage location to the scanning position by means of a simple straight translation. Moreover, each resident tube is supported inside the corresponding Vacuum Vessel and Cryostat port extensions, which are part of the primary confinement barrier. As the Vacuum Vessel and the Cryostat will move with respect to each other during operation (especially during baking) and during incidents and accidents (disruptions, vertical displacement events, seismic events), the structural integrity of the resident tube and the surrounding vacuum boundaries would be compromised if the required flexibility and supports are not appropriately assured. This paper focuses on the integration of the present design of the IVVS into the Vacuum Vessel and Cryostat environment. It presents the adopted strategy to withstand all the main interfacing loads without damaging the confinement barriers and the corresponding analysis supporting it.

  12. A Case of Bilateral Acute Calcific Tendinitis of the Gluteus Medius, Treated by Ultrasound-guided Needle Lavage and Corticosteroid Injection

    OpenAIRE

    Vereecke, Elke; Mermuys, Koen; Casselman, Jan

    2015-01-01

    Calcium hydroxyapatite deposition disease is a common pathology, most frequently located in the rotator cuff tendons of the shoulder, for which different therapeutic approaches are used. Ultrasound guided needle lavage and injection of anesthetic/corticosteroid is a well-known and extensively described treatment for calcific tendinits of the rotator cuff. We present a case of bilateral calcific tendinitis of the gluteus medius tendon, both sides successfully treated using ultrasound guided ne...

  13. Evaluation of the setup margins for cone beam computed tomography–guided cranial radiosurgery: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Calvo Ortega, Juan Francisco, E-mail: jfcdrr@yahoo.es [Department of Radiation Oncology, Hospital Quirón, Barcelona (Spain); Wunderink, Wouter [Department of Radiotherapy, Erasmus MC Cancer Institute, University Medical Center Rotterdam, Rotterdam (Netherlands); Delgado, David; Moragues, Sandra; Pozo, Miquel; Casals, Joan [Department of Radiation Oncology, Hospital Quirón, Barcelona (Spain)

    2016-10-01

    The aim of this study is to evaluate the setup margins from the clinical target volume (CTV) to planning target volume (PTV) for cranial stereotactic radiosurgery (SRS) treatments guided by cone beam computed tomography (CBCT). We designed an end-to-end (E2E) test using a skull phantom with an embedded 6mm tungsten ball (target). A noncoplanar plan was computed (E2E plan) to irradiate the target. The CBCT-guided positioning of the skull phantom on the linac was performed. Megavoltage portal images were acquired after 15 independent deliveries of the E2E plan. The displacement 2-dimensional (2D) vector between the centers of the square field and the ball target on each portal image was used to quantify the isocenter accuracy. Geometrical margins on each patient's direction (left-right or LR, anterior-posterior or AP, superior-inferior or SI) were calculated. Dosimetric validation of the margins was performed in 5 real SRS cases: 3-dimesional (3D) isocenter deviations were mimicked, and changes in CTV dose coverage and organs-at-risk (OARs) dosage were analyzed. The CTV-PTV margins of 1.1 mm in LR direction, and 0.7 mm in AP and SI directions were derived from the E2E tests. The dosimetric analysis revealed that a 1-mm uniform margin was sufficient to ensure the CTV dose coverage, without compromising the OAR dose tolerances. The effect of isocenter uncertainty has been estimated to be 1 mm in our CBCT-guided SRS approach.

  14. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Children's (pediatric) abdominal ultrasound imaging produces pictures ...

  15. Real-time registration of 3D to 2D ultrasound images for image-guided prostate biopsy.

    Science.gov (United States)

    Gillies, Derek J; Gardi, Lori; De Silva, Tharindu; Zhao, Shuang-Ren; Fenster, Aaron

    2017-09-01

    During image-guided prostate biopsy, needles are targeted at tissues that are suspicious of cancer to obtain specimen for histological examination. Unfortunately, patient motion causes targeting errors when using an MR-transrectal ultrasound (TRUS) fusion approach to augment the conventional biopsy procedure. This study aims to develop an automatic motion correction algorithm approaching the frame rate of an ultrasound system to be used in fusion-based prostate biopsy systems. Two modes of operation have been investigated for the clinical implementation of the algorithm: motion compensation using a single user initiated correction performed prior to biopsy, and real-time continuous motion compensation performed automatically as a background process. Retrospective 2D and 3D TRUS patient images acquired prior to biopsy gun firing were registered using an intensity-based algorithm utilizing normalized cross-correlation and Powell's method for optimization. 2D and 3D images were downsampled and cropped to estimate the optimal amount of image information that would perform registrations quickly and accurately. The optimal search order during optimization was also analyzed to avoid local optima in the search space. Error in the algorithm was computed using target registration errors (TREs) from manually identified homologous fiducials in a clinical patient dataset. The algorithm was evaluated for real-time performance using the two different modes of clinical implementations by way of user initiated and continuous motion compensation methods on a tissue mimicking prostate phantom. After implementation in a TRUS-guided system with an image downsampling factor of 4, the proposed approach resulted in a mean ± std TRE and computation time of 1.6 ± 0.6 mm and 57 ± 20 ms respectively. The user initiated mode performed registrations with in-plane, out-of-plane, and roll motions computation times of 108 ± 38 ms, 60 ± 23 ms, and 89 ± 27 ms, respectively, and corresponding

  16. Does ultrasound-guided lidocaine injection improve local anaesthesia before femoral artery catheterization?

    International Nuclear Information System (INIS)

    Spiliopoulos, S.; Katsanos, K.; Diamantopoulos, A.; Karnabatidis, D.; Siablis, D.

    2011-01-01

    Aim: To present the results of a prospective, randomized, single-centre study investigating local anaesthesia before percutaneous common femoral artery (CFA) puncture and catheterization with the use of ultrasound-guided injection of lidocaine versus standard infiltration by manual palpation. Materials and methods: Patients scheduled to undergo diagnostic or therapeutic transfemoral catheter-based procedures gave informed consent and were randomized in two groups. In the first arm local anaesthesia with lidocaine hydrochloride 1% was performed under ultrasound guidance (group U/S), while in the second arm the standard method of manual artery palpation was applied (group M). In both groups, subsequent CFA catheterization was achieved under ultrasound guidance. The primary study endpoint was peri-procedural pain level evaluated with a visual-analogue scale (VAS score 0-10). Results: Between January 2009 and 2010, 200 patients (161 men, mean age 63 ± 12 years) were equally assigned to each group without any significant differences in baseline demographics. Patients in group U/S experienced significantly less pain during CFA catheterization in comparison with group M with a difference of three points in mean VAS score reported (1.6 ± 1.6 versus 4.6 ± 1.9, p < 0.0001). In addition, significantly less volume of lidocaine was used in group U/S compared to group M (16 ± 2.7 versus 19 ± 0.8 ml, p < 0.001).Total vascular access time was similar in both groups (4.4 ± 1.3 versus 4.5 ± 1.3 min). Overall complications included two small groin haematomas in each group. Conclusion: Ultrasound-guided local anaesthesia of the CFA prior to percutaneous transcatheter procedures is safe and achieves superior levels of analgesia with minimal patient pain and discomfort compared to the standard method of manual palpation.

  17. Does ultrasound-guided lidocaine injection improve local anaesthesia before femoral artery catheterization?

    Energy Technology Data Exchange (ETDEWEB)

    Spiliopoulos, S., E-mail: stavspiliop@upatras.g [Department of Diagnostic and Interventional Radiology, Patras University Hospital, School of Medicine, Patras (Greece); Katsanos, K.; Diamantopoulos, A.; Karnabatidis, D.; Siablis, D. [Department of Diagnostic and Interventional Radiology, Patras University Hospital, School of Medicine, Patras (Greece)

    2011-05-15

    Aim: To present the results of a prospective, randomized, single-centre study investigating local anaesthesia before percutaneous common femoral artery (CFA) puncture and catheterization with the use of ultrasound-guided injection of lidocaine versus standard infiltration by manual palpation. Materials and methods: Patients scheduled to undergo diagnostic or therapeutic transfemoral catheter-based procedures gave informed consent and were randomized in two groups. In the first arm local anaesthesia with lidocaine hydrochloride 1% was performed under ultrasound guidance (group U/S), while in the second arm the standard method of manual artery palpation was applied (group M). In both groups, subsequent CFA catheterization was achieved under ultrasound guidance. The primary study endpoint was peri-procedural pain level evaluated with a visual-analogue scale (VAS score 0-10). Results: Between January 2009 and 2010, 200 patients (161 men, mean age 63 {+-} 12 years) were equally assigned to each group without any significant differences in baseline demographics. Patients in group U/S experienced significantly less pain during CFA catheterization in comparison with group M with a difference of three points in mean VAS score reported (1.6 {+-} 1.6 versus 4.6 {+-} 1.9, p < 0.0001). In addition, significantly less volume of lidocaine was used in group U/S compared to group M (16 {+-} 2.7 versus 19 {+-} 0.8 ml, p < 0.001).Total vascular access time was similar in both groups (4.4 {+-} 1.3 versus 4.5 {+-} 1.3 min). Overall complications included two small groin haematomas in each group. Conclusion: Ultrasound-guided local anaesthesia of the CFA prior to percutaneous transcatheter procedures is safe and achieves superior levels of analgesia with minimal patient pain and discomfort compared to the standard method of manual palpation.

  18. Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms.

    Science.gov (United States)

    Ben-Shlomo, A; Cohen, D; Bruckheimer, E; Bachar, G N; Konstantinovsky, R; Birk, E; Atar, E

    2016-05-01

    To compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT. Effective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms. The effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590% for upper lung, 639 and 525% for mid-lung, and 461 and 251% for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762% for liver and 513 and 608% for kidney biopsies. Based on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

  19. Ultrasound assessment of the posterior circumflex humeral artery in elite volleyball players: Aneurysm prevalence, anatomy, branching pattern and vessel characteristics.

    Science.gov (United States)

    van de Pol, Daan; Maas, Mario; Terpstra, Aart; Pannekoek-Hekman, Marja; Alaeikhanehshir, Sena; Kuijer, P Paul F M; Planken, R Nils

    2017-03-01

    To determine the prevalence of posterior circumflex humeral artery (PCHA) aneurysms and vessel characteristics of the PCHA and deep brachial artery (DBA) in elite volleyball players. Two-hundred and eighty players underwent standardized ultrasound assessment of the dominant arm by a vascular technologist. Assessment included determination of PCHA aneurysms (defined as segmental vessel dilatation ≥150 %), PCHA and DBA anatomy, branching pattern, vessel course and diameter. The PCHA and DBA were identified in 100 % and 93 % (260/280) of cases, respectively. The prevalence of PCHA aneurysms was 4.6 % (13/280). All aneurysms were detected in proximal PCHA originating from the axillary artery (AA). The PCHA originated from the AA in 81 % of cases (228/280), and showed a curved course dorsally towards the humeral head in 93 % (211/228). The DBA originated from the AA in 73 % of cases (190/260), and showed a straight course parallel to the AA in 93 % (177/190). PCHA aneurysm prevalence in elite volleyball players is high and associated with a specific branching type: a PCHA that originates from the axillary artery. Radiologists should have a high index of suspicion for this vascular overuse injury. For the first time vessel characteristics and reference values are described to facilitate ultrasound assessment. • Prevalence of PCHA aneurysms is 4.6 % among elite volleyball players. • All aneurysms are in proximal PCHA that originates directly from AA. • Vessel characteristics and reference values are described to facilitate US assessment. • Mean PCHA and DBA diameters can be used as reference values. • Radiologists need a high index of suspicion for this vascular overuse injury.

  20. Ultrasound guided percutaneous treatment and follow-up of Baker's cyst in knee osteoarthritis

    International Nuclear Information System (INIS)

    Köroğlu, Mert; Çallıoğlu, Mehmet; Eriş, Hüseyin Naim; Kayan, Mustafa; Çetin, Meltem; Yener, Mahmut; Gürses, Cemil; Erol, Bekir; Türkbey, Barış; Parlak, Ayşe Eda; Akhan, Okan

    2012-01-01

    Objective: Purpose of this study is to assess sonographic changes and clinical response in different subgroups of Baker's cyst patients with knee osteoarthritis after a single session of ultrasound-guided percutaneous aspiration and corticosteroid injection. Materials and methods: Thirty-two knee osteoarthritis patients (46–85 years, mean 58.97 ± 9.88) with symptomatic Baker's cyst diagnosed at ultrasonography were included in the study. To determine the grade of the symptoms, Visual Analogue Scale was applied. The patients were grouped in two, as simple (n = 24) and complex (n = 8) Baker's cyst. Thirty-two ultrasound-guided cyst aspirations concomitant 1 ml betamethasone injection (24 simple, 8 complex subgroups) were performed. Patients were followed clinically as well as via ultrasonography for 6 months after procedures. Results: A significant decrease in volume of the Baker's cysts after percutaneous treatment was accompanied by a significant clinical improvement. Moreover, the volume reduction of Baker's cyst after the treatment was significantly correlated with the clinical improvement (Pearson correlation coefficient = 0.542, p = 0.001). All 6 Baker's cysts relapsed at ultrasonography were complex type. Furthermore, a comparison of patients with simple Baker's cysts and those with complex Baker's cysts demonstrated no significant change in Visual Analogue Scale scores between two groups (p = 0.061, Mann–Whitney U). No complications (minor or major) occurred secondary to percutaneous treatment. Conclusion: Baker's cysts can be grouped as simple and complex groups via ultrasonography prior to the treatment. Cyst aspiration with ultrasound-guided corticosteroid injection yields clinical improvement and cyst volume reduction in all subgroups of patients with Baker's cyst secondary to knee osteoarthritis.

  1. Ultrasound-guided photoacoustic imaging of lymph nodes with biocompatible gold nanoparticles as a novel contrast agent (Conference Presentation)

    Science.gov (United States)

    Sun, In-Cheol; Dumani, Diego; Emelianov, Stanislav Y.

    2017-02-01

    A key step in staging cancer is the diagnosis of metastasis that spreads through lymphatic system. For this reason, researchers develop various methods of sentinel lymph node mapping that often use a radioactive tracer. This study introduces a safe, cost-effective, high-resolution, high-sensitivity, and real-time method of visualizing the sentinel lymph node: ultrasound-guided photoacoustic (US/PA) imaging augmented by a contrast agent. In this work, we use clearable gold nanoparticles covered by a biocompatible polymer (glycol chitosan) to enhance cellular uptake by macrophages abundant in lymph nodes. We incubate macrophages with glycol-chitosan-coated gold nanoparticles (0.05 mg Au/ml), and then fix them with paraformaldehyde solution for an analysis of in vitro dark-field microscopy and cell phantom. The analysis shows enhanced cellular uptake of nanoparticles by macrophages and strong photoacoustic signal from labeled cells in tissue-mimicking cell phantoms consisting gelatin solution (6 %) with silica gel (25 μm, 0.3%) and fixed macrophages (13 X 105 cells). The in-vivo US/PA imaging of cervical lymph nodes in healthy mice (nu/nu, female, 5 weeks) indicates a strong photoacoustic signal from a lymph node 10 minutes post-injection (2.5 mg Au/ml, 80 μl). The signal intensity and the nanoparticle-labeled volume of tissue within the lymph node continues to increase until 4 h post-injection. Histological analysis further confirms the accumulation of gold nanoparticles within the lymph nodes. This work suggests the feasibility of molecular/cellular US/PA imaging with biocompatible gold nanoparticles as a photoacoustic contrast agent in the diagnosis of lymph-node-related diseases.

  2. 3D printed abdominal aortic aneurysm phantom for image guided surgical planning with a patient specific fenestrated endovascular graft system

    Science.gov (United States)

    Meess, Karen M.; Izzo, Richard L.; Dryjski, Maciej L.; Curl, Richard E.; Harris, Linda M.; Springer, Michael; Siddiqui, Adnan H.; Rudin, Stephen; Ionita, Ciprian N.

    2017-03-01

    Following new trends in precision medicine, Juxatarenal Abdominal Aortic Aneurysm (JAAA) treatment has been enabled by using patient-specific fenestrated endovascular grafts. The X-ray guided procedure requires precise orientation of multiple modular endografts within the arteries confirmed via radiopaque markers. Patient-specific 3D printed phantoms could familiarize physicians with complex procedures and new devices in a risk-free simulation environment to avoid periprocedural complications and improve training. Using the Vascular Modeling Toolkit (VMTK), 3D Data from a CTA imaging of a patient scheduled for Fenestrated EndoVascular Aortic Repair (FEVAR) was segmented to isolate the aortic lumen, thrombus, and calcifications. A stereolithographic mesh (STL) was generated and then modified in Autodesk MeshMixer for fabrication via a Stratasys Eden 260 printer in a flexible photopolymer to simulate arterial compliance. Fluoroscopic guided simulation of the patient-specific FEVAR procedure was performed by interventionists using all demonstration endografts and accessory devices. Analysis compared treatment strategy between the planned procedure, the simulation procedure, and the patient procedure using a derived scoring scheme. Results: With training on the patient-specific 3D printed AAA phantom, the clinical team optimized their procedural strategy. Anatomical landmarks and all devices were visible under x-ray during the simulation mimicking the clinical environment. The actual patient procedure went without complications. Conclusions: With advances in 3D printing, fabrication of patient specific AAA phantoms is possible. Simulation with 3D printed phantoms shows potential to inform clinical interventional procedures in addition to CTA diagnostic imaging.

  3. Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game

    Science.gov (United States)

    Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann

    Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.

  4. Development of an intravascular ultrasound elastography based on a dual-element transducer

    Science.gov (United States)

    Shih, Cho-Chiang; Chen, Pei-Yu; Ma, Teng; Zhou, Qifa; Shung, K. Kirk; Huang, Chih-Chung

    2018-04-01

    The ability to measure the elastic properties of plaques and vessels would be useful in clinical diagnoses, particularly for detecting a vulnerable plaque. This study demonstrates the feasibility of the combination of intravascular ultrasound (IVUS) and acoustic radiation force elasticity imaging for detecting the distribution of stiffness within atherosclerotic arteries ex vivo. A dual-frequency IVUS transducer with two elements was used to induce the propagation of the shear wave (by the 8.5 MHz pushing element) which could be simultaneously monitored by the 31 MHz imaging element. The wave-amplitude image and the wave-velocity image were reconstructed by measuring the peak displacement and wave velocity of shear wave propagation, respectively. System performance was verified using gelatin phantoms. The phantom results demonstrate that the stiffness differences of shear modulus of 1.6 kPa can be distinguished through the wave-amplitude and wave-velocity images. The stiffness distributions of the atherosclerotic aorta from a rabbit were obtained, for which the values of peak displacement and the shear wave velocity were 3.7 ± 1.2 µm and 0.38 ± 0.19 m s-1 for the lipid-rich plaques, and 1.0 ± 0.2 µm and 3.45 ± 0.45 m s-1 for the arterial walls, respectively. These results indicate that IVUS elasticity imaging can be used to distinguish the elastic properties of plaques and vessels.

  5. Effects of using simulation versus CD-ROM in the performance of ultrasound-guided regional anesthesia.

    Science.gov (United States)

    Gasko, John; Johnson, Arthur; Sherner, John; Craig, John; Gegel, Brian; Burgert, James; Sama, Samuel; Franzen, Thomas

    2012-08-01

    The purpose of this study was to determine which method of teaching, CD-ROM, simulation, or a combination of both, was more effective in increasing the performance of ultrasound-guided regional anesthesia. No studies have investigated these methods. The framework for this study was critical thinking. The study was a prospective, mixed (between and within) subjects, experimental design. The sample consisted of 29 student registered nurse anesthetists randomly assigned to 1 of 3 groups: CD-ROM (n = 11), simulation (n = 11), and combination (n = 7). All groups were evaluated by the use of cadavers before and 2 months after the intervention using a valid and reliable instrument of performance. A repeated-measures analysis of variance indicated that the combination was significantly better than the CD-ROM and simulation (P teaching ultrasound-guided regional anesthesia techniques.

  6. Ultrasound-Guided Angioplasty of Dysfunctional Vascular Access for Haemodialysis. The Pros and Cons

    Energy Technology Data Exchange (ETDEWEB)

    García-Medina, J., E-mail: josegmedina57@gmail.com [“Reina Sofia” University Hospital, Vascular and Interventional Radiology Unit, Department of Radiology (Spain); García-Alfonso, J. J., E-mail: juanjozarandieta@gmail.com [University of Murcia, Faculty of Medicine (Spain)

    2017-05-15

    PurposeTo describe the benefits and the disadvantages of angioplasty in dialysis fistulas using only ultrasound guidance.Materials and MethodsThis is a prospective study in 132 failing or non-maturing arteriovenous accesses that underwent 189 ultrasound-guided balloon angioplasties. The technical success was defined as non-use of X-ray fluoroscopy during the procedure.Results127 procedures (67%) were successfully completed without fluoroscopy. Most failures were due to difficulty to traverse aneurismal segments, as well as anastomotic stenoses. Including initial failures, the primary patency rates at 6, 12 months and 2 years were 75 ± 3, 41 ± 3 and 14 ± 2%, respectively.ConclusionEndovascular repair of the dysfunctional vascular access for haemodialysis under ultrasound guidance is feasible and safe in roughly two-thirds of cases.

  7. Alleviating Pancreatic Cancer-Associated Pain Using Endoscopic Ultrasound-Guided Neurolysis

    Science.gov (United States)

    Takenaka, Mamoru; Kamata, Ken; Yoshikawa, Tomoe; Nakai, Atsushi; Omoto, Shunsuke; Miyata, Takeshi; Yamao, Kentaro; Imai, Hajime; Sakamoto, Hiroki; Kitano, Masayuki; Kudo, Masatoshi

    2018-01-01

    The most common symptom in patients with advanced pancreatic cancer is abdominal pain. This has traditionally been treated with nonsteroidal anti-inflammatory drugs and opioid analgesics. However, these treatments result in inadequate pain control or drug-related adverse effects in some patients. An alternative pain-relief modality is celiac plexus neurolysis, in which the celiac plexus is chemically ablated. This procedure was performed percutaneously or intraoperatively until 1996, when endoscopic ultrasound (EUS)-guided celiac plexus neurolysis was first described. In this transgastric anterior approach, a neurolytic agent is injected around the celiac trunk under EUS guidance. The procedure gained popularity as a minimally invasive approach and is currently widely used to treat pancreatic cancer-associated pain. We focus on two relatively new techniques of EUS-guided neurolysis: EUS-guided celiac ganglia neurolysis and EUS-guided broad plexus neurolysis, which have been developed to improve efficacy. Although the techniques are safe and effective in general, some serious adverse events including ischemic and infectious complications have been reported as the procedure has gained widespread popularity. We summarize reported clinical outcomes of EUS-guided neurolysis in pancreatic cancer (from the PubMed and Embase databases) with a goal of providing information useful in developing strategies for pancreatic cancer-associated pain alleviation. PMID:29462851

  8. Ultrasound-guided percutaneous radiofrequency ablation of liver tumors: How we do it safety and completely

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Woong; Shin, Sang Soo; Heo, Suk Hee; Hong, Jun Hyung; Lim, Hyo Soon; Seon, Hyun Ju; Hur, Young Hoe; Park, Chang Hwan; Jeong, Yong Yeon; Kang, Heoung Keun [Chonnam National University Medical School, Gwangju (Korea, Republic of)

    2015-12-15

    Ultrasound-guided percutaneous radiofrequency (RF) ablation has become one of the most promising local cancer therapies for both resectable and nonresectable hepatic tumors. Although RF ablation is a safe and effective technique for the treatment of liver tumors, the outcome of treatment can be closely related to the location and shape of the tumors. There may be difficulties with RF ablation of tumors that are adjacent to large vessels or extrahepatic heat-vulnerable organs and tumors in the caudate lobe, possibly resulting in major complications or treatment failure. Thus, a number of strategies have been developed to overcome these challenges, which include artificial ascites, needle track ablation, fusion imaging guidance, parallel targeting, bypass targeting, etc. Operators need to use the right strategy in the right situation to avoid the possibility of complications and incomplete thermal tissue destruction; with the right strategy, RF ablation can be performed successfully, even for hepatic tumors in high-risk locations. This article offers technical strategies that can be used to effectively perform RF ablation as well as to minimize possible complications related to the procedure with representative cases and schematic illustrations.

  9. Endoscopic ultrasound-guided hepaticogastrostomy for advanced cholangiocarcinoma after failed stenting by endoscopic retrograde cholangiopancreatography

    Directory of Open Access Journals (Sweden)

    Sukij Panpimanmas

    2013-10-01

    Conclusion: Endoscopic-ultrasound-guided hepaticogastrostomy is safe and can be a good palliative option for advanced malignant biliary obstruction because it drains internally and is remote from the tumor site, promoting a long patency period of prosthesis and better quality of life.

  10. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... imaging produces pictures of the internal organs and blood vessels located within a child's abdomen. A Doppler ultrasound study may be part of a child's abdominal ultrasound ...

  11. Ultrasound-guided lateral infraclavicular block evaluated by infrared thermography and distal skin temperature

    DEFF Research Database (Denmark)

    Asghar, Semera; Lundstrøm, Lars Hyldborg; Bjerregaard, Lars Stryhn

    2014-01-01

    of the 2nd and 5th digits. METHODS: We performed an ultrasound-guided lateral infraclavicular block in 45 patients undergoing upper limb surgery. The contralateral hand served as control and we obtained infrared thermographic images of both hands before the block and during the following 30 min. We defined...

  12. A method for the measurement of dispersion curves of circumferential guided waves radiating from curved shells: experimental validation and application to a femoral neck mimicking phantom

    Science.gov (United States)

    Nauleau, Pierre; Minonzio, Jean-Gabriel; Chekroun, Mathieu; Cassereau, Didier; Laugier, Pascal; Prada, Claire; Grimal, Quentin

    2016-07-01

    Our long-term goal is to develop an ultrasonic method to characterize the thickness, stiffness and porosity of the cortical shell of the femoral neck, which could enhance hip fracture risk prediction. To this purpose, we proposed to adapt a technique based on the measurement of guided waves. We previously evidenced the feasibility of measuring circumferential guided waves in a bone-mimicking phantom of a circular cross-section of even thickness. The goal of this study is to investigate the impact of the complex geometry of the femoral neck on the measurement of guided waves. Two phantoms of an elliptical cross-section and one phantom of a realistic cross-section were investigated. A 128-element array was used to record the inter-element response matrix of these waveguides. This experiment was simulated using a custom-made hybrid code. The response matrices were analyzed using a technique based on the physics of wave propagation. This method yields portions of dispersion curves of the waveguides which were compared to reference dispersion curves. For the elliptical phantoms, three portions of dispersion curves were determined with a good agreement between experiment, simulation and theory. The method was thus validated. The characteristic dimensions of the shell were found to influence the identification of the circumferential wave signals. The method was then applied to the signals backscattered by the superior half of constant thickness of the realistic phantom. A cut-off frequency and some portions of modes were measured, with a good agreement with the theoretical curves of a plate waveguide. We also observed that the method cannot be applied directly to the signals backscattered by the lower half of varying thicknesses of the phantom. The proposed approach could then be considered to evaluate the properties of the superior part of the femoral neck, which is known to be a clinically relevant site.

  13. Phased laser diode array permits selective excitation of ultrasonic guided waves in coated bone-mimicking tubes

    Science.gov (United States)

    Moilanen, Petro; Salmi, Ari; Kilappa, Vantte; Zhao, Zuomin; Timonen, Jussi; Hæggström, Edward

    2017-10-01

    This paper validates simulation predictions, which state that specific modes could be enhanced in quantitative ultrasonic bone testing. Tunable selection of ultrasonic guided wave excitation is useful in non-destructive testing since it permits the mediation of energy into diagnostically useful modes while reducing the energy mediated into disturbing contributions. For instance, it is often challenging to distinguish and extract the useful modes from ultrasound signals measured in bone covered by a soft tissue. We show that a laser diode array can selectively excite ultrasound in bone mimicking phantoms. A fiber-coupled diode array (4 elements) illuminated two solid tubes (2-3 mm wall thickness) embraced by an opaque soft-tissue mimicking elastomer coating (5 mm thick). A predetermined time delay matching the selected mode and frequency was employed between the outputs of the elements. The generated ultrasound was detected by a 215 kHz piezo receiver. Our results suggest that this array reduces the disturbances caused by the elastomer cover and so pave way to permit non-contacting in vivo guided wave ultrasound assessment of human bones. The implementation is small, inexpensive, and robust in comparison with the conventional pulsed lasers.

  14. Computer tomography urography assisted real-time ultrasound-guided percutaneous nephrolithotomy on renal calculus.

    Science.gov (United States)

    Fang, You-Qiang; Wu, Jie-Ying; Li, Teng-Cheng; Zheng, Hao-Feng; Liang, Guan-Can; Chen, Yan-Xiong; Hong, Xiao-Bin; Cai, Wei-Zhong; Zang, Zhi-Jun; Di, Jin-Ming

    2017-06-01

    This study aimed to assess the role of pre-designed route on computer tomography urography (CTU) in the ultrasound-guided percutaneous nephrolithotomy (PCNL) for renal calculus.From August 2013 to May 2016, a total of 100 patients diagnosed with complex renal calculus in our hospital were randomly divided into CTU group and control group (without CTU assistance). CTU was used to design a rational route for puncturing in CTU group. Ultrasound was used in both groups to establish a working trace in the operation areas. Patients' perioperative parameters and postoperative complications were recorded.All operations were successfully performed, without transferring to open surgery. Time of channel establishment in CTU group (6.5 ± 4.3 minutes) was shorter than the control group (10.0 ± 6.7 minutes) (P = .002). In addition, there was shorter operation time, lower rates of blood transfusion, secondary operation, and less establishing channels. The incidence of postoperative complications including residual stones, sepsis, severe hemorrhage, and perirenal hematoma was lower in CTU group than in control group.Pre-designing puncture route on CTU images would improve the puncturing accuracy, lessen establishing channels as well as improve the security in the ultrasound-guided PCNL for complex renal calculus, but at the cost of increased radiation exposure.

  15. MO-DE-210-05: Improved Accuracy of Liver Feature Motion Estimation in B-Mode Ultrasound for Image-Guided Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    O’Shea, T; Bamber, J; Harris, E [The Institute of Cancer Research & Royal Marsden, Sutton and London (United Kingdom)

    2015-06-15

    Purpose: In similarity-measure based motion estimation incremental tracking (or template update) is challenging due to quantization, bias and accumulation of tracking errors. A method is presented which aims to improve the accuracy of incrementally tracked liver feature motion in long ultrasound sequences. Methods: Liver ultrasound data from five healthy volunteers under free breathing were used (15 to 17 Hz imaging rate, 2.9 to 5.5 minutes in length). A normalised cross-correlation template matching algorithm was implemented to estimate tissue motion. Blood vessel motion was manually annotated for comparison with three tracking code implementations: (i) naive incremental tracking (IT), (ii) IT plus a similarity threshold (ST) template-update method and (iii) ST coupled with a prediction-based state observer, known as the alpha-beta filter (ABST). Results: The ABST method produced substantial improvements in vessel tracking accuracy for two-dimensional vessel motion ranging from 7.9 mm to 40.4 mm (with mean respiratory period: 4.0 ± 1.1 s). The mean and 95% tracking errors were 1.6 mm and 1.4 mm, respectively (compared to 6.2 mm and 9.1 mm, respectively for naive incremental tracking). Conclusions: High confidence in the output motion estimation data is required for ultrasound-based motion estimation for radiation therapy beam tracking and gating. The method presented has potential for monitoring liver vessel translational motion in high frame rate B-mode data with the required accuracy. This work is support by Cancer Research UK Programme Grant C33589/A19727.

  16. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    Science.gov (United States)

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  17. Ultrasound-guided block of the axillary nerve

    DEFF Research Database (Denmark)

    Rothe, C; Lund, J; Jenstrup, M T

    2012-01-01

    The specific blocking of the axillary nerve has never been investigated clinically. We present four cases illustrating potential applications of the axillary nerve block in the perioperative setting and discuss possible directions for future research in this area. The axillary nerve blocks were all...... performed using a newly developed in-plane ultrasound-guided technique. In one patient undergoing arthroscopic shoulder surgery, we used the axillary nerve block as the only analgesic combined with propofol sedation and spontaneous breathing. Chronic shoulder pain was eliminated after the axillary nerve...... block in two patients. The pain score after arthroscopic shoulder surgery in these two patients remained low until termination of the nerve block. In a fourth patient, severe post-operative pain after osteosynthesis of a displaced proximal humerus fracture was almost eliminated after performing...

  18. Recent advances on the development of phantoms using 3D printing for imaging with CT, MRI, PET, SPECT and Ultrasound.

    Science.gov (United States)

    Filippou, Valeria; Tsoumpas, Charalampos

    2018-06-22

    Printing technology, capable of producing three-dimensional (3D) objects, has evolved in recent years and provides potential for developing reproducible and sophisticated physical phantoms. 3D printing technology can help rapidly develop relatively low cost phantoms with appropriate complexities, which are useful in imaging or dosimetry measurements. The need for more realistic phantoms is emerging since imaging systems are now capable of acquiring multimodal and multiparametric data. This review addresses three main questions about the 3D printers currently in use, and their produced materials. The first question investigates whether the resolution of 3D printers is sufficient for existing imaging technologies. The second question explores if the materials of 3D-printed phantoms can produce realistic images representing various tissues and organs as taken by different imaging modalities such as computer tomography (CT), positron emission tomography (PET), single-photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), ultrasound (US), and mammography. The emergence of multimodal imaging increases the need for phantoms that can be scanned using different imaging modalities. The third question probes the feasibility and easiness of "printing" radioactive and/or non-radioactive solutions during the printing process. A systematic review of medical imaging studies published after January 2013 is performed using strict inclusion criteria. The databases used were Scopus and Web of Knowledge with specific search terms. In total, 139 papers were identified, however only 50 were classified as relevant for the purpose of this paper. In this review, following an appropriate introduction and literature research strategy, all 50 articles are presented in detail. A summary of tables and example figures of the most recent advances in 3D printing for the purposes of phantoms across different imaging modalities are provided. All 50 studies printed and scanned

  19. The efficacy of an ultrasound-guided core needle biopsy with an 18G cutting needle for the diagnosis of pancreatic diseases

    International Nuclear Information System (INIS)

    Jung, Sung Hwa; Park, Won Kyu; Chang, Jay Chun; Kim, Jae Woon; Cho, Jae Ho; Jang, Han Won; Lee, Jae Kyo; Choi, Joon Hyuk

    2008-01-01

    The objective of this study is to evaluate the efficacy and safety of an ultrasound-guided core needle biopsy with an 18G cutting needle in patients suspected of having a pancreatic disease by analyzing the diagnostic performance and complication rate. The study population comprised 35 consecutive patients who underwent an ultrasound-guided core needle biopsy using a high-speed biopsy gun accompanied with an 18G cutting-type needle between May of 2001 and October of 2005. The diagnostic performance (i.e., the acquisition rate and diagnostic accuracy) and complications associated with core needle biopsies were evaluated for its efficacy and safety. Thirty-six sessions of ultrasound-guided core needle biopsies were performed in 35 consecutive patients. All patients, except two (serous cystadenoma and autoimmune pancreatitis) were diagnosed with various subtypes of pancreatic cancer. The acquisition rate and diagnostic accuracy were 97% (35/36) and 94% (34/36), respectively. A complication occurred only in one patient (3%), which further proved to be a delayed complication (i.e., needle tract implantation). According to our findings, the ultrasound-guided core needle biopsy is a viable and safe method for the diagnosis of pancreatic diseases. Moreover, it enables the diagnosis of the pancreatic cancer subtype

  20. A new instrument to assess physician skill at thoracic ultrasound, including pleural effusion markup.

    Science.gov (United States)

    Salamonsen, Matthew; McGrath, David; Steiler, Geoff; Ware, Robert; Colt, Henri; Fielding, David

    2013-09-01

    To reduce complications and increase success, thoracic ultrasound is recommended to guide all chest drainage procedures. Despite this, no tools currently exist to assess proceduralist training or competence. This study aims to validate an instrument to assess physician skill at performing thoracic ultrasound, including effusion markup, and examine its validity. We developed an 11-domain, 100-point assessment sheet in line with British Thoracic Society guidelines: the Ultrasound-Guided Thoracentesis Skills and Tasks Assessment Test (UGSTAT). The test was used to assess 22 participants (eight novices, seven intermediates, seven advanced) on two occasions while performing thoracic ultrasound on a pleural effusion phantom. Each test was scored by two blinded expert examiners. Validity was examined by assessing the ability of the test to stratify participants according to expected skill level (analysis of variance) and demonstrating test-retest and intertester reproducibility by comparison of repeated scores (mean difference [95% CI] and paired t test) and the intraclass correlation coefficient. Mean scores for the novice, intermediate, and advanced groups were 49.3, 73.0, and 91.5 respectively, which were all significantly different (P < .0001). There were no significant differences between repeated scores. Procedural training on mannequins prior to unsupervised performance on patients is rapidly becoming the standard in medical education. This study has validated the UGSTAT, which can now be used to determine the adequacy of thoracic ultrasound training prior to clinical practice. It is likely that its role could be extended to live patients, providing a way to document ongoing procedural competence.

  1. Detection of a coronary artery vessel wall: performance of 0.3 mm fine-cell detector computed tomography-a phantom study

    International Nuclear Information System (INIS)

    Yamada, Minoru; Jinzaki, Masahiro; Tanami, Yutaka; Matsumoto, Kazuhiro; Ueno, Akihisa; Kuribayashi, Sachio; Nukui, Masatake; Imai, Yasuhiro; Ishihara, Yotaro; Nishide, Akihiko; Sasaki, Kosuke

    2011-01-01

    The purpose of this study was to evaluate whether experimental fine-cell detector computed tomography with a 0.3125 mm cell (0.3 mm cell CT) can improve the detection of coronary vessel walls compared with conventional 64-slice computed tomography with a 0.625 mm cell (0.6 mm cell CT). A coronary vessel wall phantom was scanned using 0.6 mm cell CT and 0.3 mm cell CT. The data for 0.3 mm cell CT were obtained using four protocols: a radiation dose equal, double, triple or quadruple that were used in the 0.6 mm cell CT protocol. The detectable size of the vessel wall was assessed based on the first and second derivative functions, and the minimum measurable values were compared using a paired t-test. As a result, the minimum detectable wall thickness of 0.6 mm cell CT (1.5 mm) was significantly larger than that of 0.3 mm cell CT performed using the triple- and quadruple-dose protocols (0.9 mm) and the double-dose protocol (1.1 mm). The difference in the minimum detectable vessel wall thickness measured using 0.6 mm cell CT (1.5 ± 0.1 mm) and 0.3 mm cell CT (0.9 ± 0.1 mm, 1.1 ± 0.2 mm) was significant (p < 0.01). We concluded that 0.3 mm cell CT improved the detection of coronary vessel walls when a more than double-dose protocol was used compared with 0.6 mm cell CT.

  2. Post-mortem computed tomography angiography utilizing barium sulfate to identify microvascular structures : a preliminary phantom model and case study

    NARCIS (Netherlands)

    Haakma, Wieke; Rohde, Marianne; Kuster, Lidy; Uhrenholt, Lars; Pedersen, Michael; Boel, Lene Warner Thorup

    2016-01-01

    We investigated the use of computer tomography angiography (CTA) to visualize microvascular structures in a vessel-mimicking phantom and post-mortem (PM) bodies. A contrast agent was used based on 22% barium sulfate, 20% polyethylene glycol and 58% distilled water. A vessel-mimicking phantom

  3. Three-dimensional ultrasound image-guided robotic system for accurate microwave coagulation of malignant liver tumours.

    Science.gov (United States)

    Xu, Jing; Jia, Zhen-zhong; Song, Zhang-jun; Yang, Xiang-dong; Chen, Ken; Liang, Ping

    2010-09-01

    The further application of conventional ultrasound (US) image-guided microwave (MW) ablation of liver cancer is often limited by two-dimensional (2D) imaging, inaccurate needle placement and the resulting skill requirement. The three-dimensional (3D) image-guided robotic-assisted system provides an appealing alternative option, enabling the physician to perform consistent, accurate therapy with improved treatment effectiveness. Our robotic system is constructed by integrating an imaging module, a needle-driven robot, a MW thermal field simulation module, and surgical navigation software in a practical and user-friendly manner. The robot executes precise needle placement based on the 3D model reconstructed from freehand-tracked 2D B-scans. A qualitative slice guidance method for fine registration is introduced to reduce the placement error caused by target motion. By incorporating the 3D MW specific absorption rate (SAR) model into the heat transfer equation, the MW thermal field simulation module determines the MW power level and the coagulation time for improved ablation therapy. Two types of wrists are developed for the robot: a 'remote centre of motion' (RCM) wrist and a non-RCM wrist, which is preferred in real applications. The needle placement accuracies were robot with the RCM wrist was improved to 1.6 +/- 1.0 mm when real-time 2D US feedback was used in the artificial-tissue phantom experiment. By using the slice guidance method, the robot with the non-RCM wrist achieved accuracy of 1.8 +/- 0.9 mm in the ex vivo experiment; even target motion was introduced. In the thermal field experiment, a 5.6% relative mean error was observed between the experimental coagulated neurosis volume and the simulation result. The proposed robotic system holds promise to enhance the clinical performance of percutaneous MW ablation of malignant liver tumours. Copyright 2010 John Wiley & Sons, Ltd.

  4. Comparison of two ultrasound-guided injection techniques targeting the sacroiliac joint region in equine cadavers.

    Science.gov (United States)

    Stack, John David; Bergamino, Chiara; Sanders, Ruth; Fogarty, Ursula; Puggioni, Antonella; Kearney, Clodagh; David, Florent

    2016-09-20

    To compare the accuracy and distribution of injectate for cranial (CR) and caudomedial (CM) ultrasound-guided injections of equine sacroiliac joints. Both sacroiliac joints from 10 lumbosacropelvic specimens were injected using cranial parasagittal (CR; curved 18 gauge, 25 cm spinal needles) and caudomedial (CM; straight 18 gauge, 15 cm spinal needles) ultrasound-guided approaches. Injectate consisted of 4 ml iodinated contrast and 2 ml methylene blue. Computed tomographical (CT) scans were performed before and after injections. Time for needle guidance and repositioning attempts were recorded. The CT sequences were analysed for accuracy and distribution of contrast. Intra-articular contrast was detected in sacroiliac joints following 15/40 injections. The CR and CM approaches deposited injectate ≤2 cm from sacroiliac joint margins following 17/20 and 20/20 injections, respectively. Median distance of closest contrast to the sacroiliac joint was 0.4 cm (interquartile range [IQR]: 1.5 cm) for CR approaches and 0.6 cm (IQR: 0.95 cm) for CM approaches. Cranial injections resulted in injectate contacting lumbosacral intertransverse joints 15/20 times. Caudomedial injections were perivascular 16/20 times. Safety and efficacy could not be established. Cranial and CM ultrasound-guided injections targeting sacroiliac joints were very accurate for periarticular injection, but accuracy was poor for intra-articular injection. Injectate was frequently found in contact with interosseous sacroiliac ligaments, as well as neurovascular and synovial structures in close vicinity of sacroiliac joints.

  5. Ultrasound in Biomedical Engineering: Ultrasound Microbubble Contrast Agents Promote Transdermal Permeation of Drugs

    OpenAIRE

    Ai-Ho Liao

    2016-01-01

    This report discusses a new development in the use of ultrasound microbubble contrast agents on transdermal drug delivery. The medium surrounding the microbubbles at the optimum concentration from liquid to gel can be modified and it can still achieve the same enhancement for transdermal drug permeation as liquid medium. It was also found that under the same ultrasound power density, microbubbles of larger particle sizes can extend the penetration depths of dye at the phantom surface.

  6. CT angiography using electron-beam computed tomography (EBCT). A phantom study

    International Nuclear Information System (INIS)

    Uchino, Akira; Kato, Akira; Kudo, Sho

    1997-01-01

    The purpose of this study was to evaluate the accuracy of CT angiography in small vessels using electron-beam computed tomography (EBCT). Vessel phantoms with inner diameters of 8 mm, 6 mm, and 4 mm were prepared with segments of 75%, 50%, and 25% stenosis in each vessel. The vessels were filled with contrast medium (Iopamidol 300 at 1/24 dilution, approximately 380 HU). The EBCT apparatus used was an Imatron C-150. The step volume scan mode was used with slice thicknesses of 1.5 mm and 3.0 mm, scan time of 0.3 sec, and 210 mm field of view. Images with a slice thickness of 1.5 mm were definitely better than those with a slice thickness of 3.0 mm. The quality of maximum intensity projection (MIP) images was quite similar to that of three-dimensional (3D) images. Using the 8 mm vessel phantom, all stenotic segments were accurately visualized on CT angiography. The 50% stenotic segments were accurately estimated in all vessels. However, the 75% stenotic segments were slightly overestimated in smaller vessels, and the 25% stenotic segments were slightly underestimated in smaller vessels. We consider CT angiography using EBCT to be a useful, less invasive diagnostic modality for stenoocclusive lesions. (author)

  7. Ultrasound-guided plantar fascia release technique: a retrospective study of 46 feet.

    Science.gov (United States)

    Vohra, Praveen K; Japour, Christopher J

    2009-01-01

    Ultrasound-guided plantar fascia release offers the surgeon clear visualization of anatomy at the surgical site. This technique uses small arthroscopic dissecting instruments through a 0.5-cm incision, allowing the surgeon to avoid the larger and more tissue-disruptive incision that is traditionally used for plantar heel spur resection and plantar fascia releases. Forty-one patients (46 feet) were selected for the study. The mean patient age was 47 years. Twenty-nine were considered obese with a body mass index greater than 30 kg/m(2). Patients were functionally and subjectively evaluated 4 weeks after surgery using the American Orthopedic Foot and Ankle Society Ankle and Hindfoot Rating Scale. Results from the study show a significant improvement (P = .05 confidence level) 4 weeks postoperatively for the 41 patients (46 feet), compared to their preoperative condition. The mean pretest score was 33.6 (range 10-52); this score improved to 88.0 (range 50-100), 4 weeks postoperatively. There were no postoperative infections or complications. The ultrasound-guided plantar fascia release technique is a practical surgical procedure for the relief of chronic plantar fascia pain because the surgeon is able to clearly visualize the plantar fascia by ultrasound. In addition, there is minimal disruption to surrounding tissue because small instruments are passed through a small 0.5-cm incision. The traditional open method of heel spur surgery, in contrast, uses a larger skin incision of 3 to 5 cm, followed by larger instruments to dissect to the plantar fascia.

  8. Value of Artisanal Simulators to Train Veterinary Students in Performing Invasive Ultrasound-Guided Procedures

    Science.gov (United States)

    Hage, Maria Cristina F. N. S.; Massaferro, Ana Beatriz; Lopes, Érika Rondon; Beraldo, Carolina Mariano; Daniel, Jéssika

    2016-01-01

    Pericardial effusion can lead to cardiac tamponade, which endangers an animal's life. Ultrasound-guided pericardiocentesis is used to remove abnormal liquid; however, it requires technical expertise. In veterinary medical education, the opportunity to teach this procedure to save lives during emergencies is rare; therefore, simulators are…

  9. Endogenous Catalytic Generation of O2 Bubbles for In Situ Ultrasound-Guided High Intensity Focused Ultrasound Ablation.

    Science.gov (United States)

    Liu, Tianzhi; Zhang, Nan; Wang, Zhigang; Wu, Meiying; Chen, Yu; Ma, Ming; Chen, Hangrong; Shi, Jianlin

    2017-09-26

    High intensity focused ultrasound (HIFU) surgery generally suffers from poor precision and low efficiency in clinical application, especially for cancer therapy. Herein, a multiscale hybrid catalytic nanoreactor (catalase@MONs, abbreviated as C@M) has been developed as a tumor-sensitive contrast and synergistic agent (C&SA) for ultrasound-guided HIFU cancer surgery, by integrating dendritic-structured mesoporous organosilica nanoparticles (MONs) and catalase immobilized in the large open pore channels of MONs. Such a hybrid nanoreactor exhibited sensitive catalytic activity toward H 2 O 2 , facilitating the continuous O 2 gas generation in a relatively mild manner even if incubated with 10 μM H 2 O 2 , which finally led to enhanced ablation in the tissue-mimicking PAA gel model after HIFU exposure mainly resulting from intensified cavitation effect. The C@M nanoparticles could be accumulated within the H 2 O 2 -enriched tumor region through enhanced permeability and retention effect, enabling durable contrast enhancement of ultrasound imaging, and highly efficient tumor ablation under relatively low power of HIFU exposure in vivo. Very different from the traditional perfluorocarbon-based C&SA, such an on-demand catalytic nanoreactor could realize the accurate positioning of tumor without HIFU prestimulation and efficient HIFU ablation with a much safer power output, which is highly desired in clinical HIFU application.

  10. Efficacy of ultrasound-guided transversus abdominis plane block for postoperative analgesia in patients undergoing inguinal hernia repair

    Directory of Open Access Journals (Sweden)

    Venkatraman R

    2016-01-01

    Full Text Available Rajagopalan Venkatraman, Ranganathan Jothi Abhinaya, Ayyanar Sakthivel, Govindarajan Sivarajan Department of Anaesthesia, SRM Medical College Hospital and Research Centre, Chennai, Tamil Nadu, India Background and aim: Transversus abdominis plane block (TAP block is a novel procedure to provide postoperative analgesia following inguinal hernia surgery. The utilization of ultrasound has greatly augmented the success rate of this block and additionally avoiding complications. The aim of our study was to gauge the analgesic efficacy of ultrasound-guided TAP block in patients undergoing unilateral inguinal hernia repair. Materials and methods: Sixty patients scheduled for elective inguinal hernia repair were selected for the study. At the end of the surgical procedure, they were randomly divided into two groups. Ultrasound-guided TAP block was performed with 20 mL of ropivacaine 0.2% (group A or normal saline (group B. Visual analog scale (VAS scores were used to assess pain. Paracetamol was given if VAS >3 and tramadol was used when VAS >6. Patients were monitored for VAS scores and total analgesic consumption for the 24-hour period. Results: The TAP block with ropivacaine (group A reduced VAS scores at 4, 6, and 12 hours. There was no distinction in VAS scores at 0, 2, and 24 hours between the two groups. The duration of analgesia for TAP block with ropivacaine lasted for 390 minutes. Total analgesics consumption was also significantly reduced in group A than group B. No complication was reported to TAP block in both the groups. Conclusion: The ultrasound-guided TAP block provides good postoperative analgesia, reduces analgesic requirements, and provides good VAS scores with fewer complications following inguinal hernia surgery. Keywords: inguinal hernia repair, postoperative analgesia, ropivacaine, transversus abdominis block, ultrasound

  11. Feasibility of contrast-enhanced ultrasound-guided biopsy of sentinel lymph nodes in dogs.

    Science.gov (United States)

    Gelb, Hylton R; Freeman, Lynetta J; Rohleder, Jacob J; Snyder, Paul W

    2010-01-01

    Our goal was to develop and validate a technique to identify the sentinel lymph nodes of the mammary glands of healthy dogs with contrast-enhanced ultrasound, and evaluate the feasibility of obtaining representative samples of a sentinel lymph node under ultrasound guidance using a new biopsy device. Three healthy intact female adult hounds were anesthetized and each received an injection of octafluoropropane-filled lipid microspheres and a separate subcutaneous injection of methylene blue dye around a mammary gland. Ultrasound was then used to follow the contrast agent through the lymphatic channel to the sentinel lymph node. Lymph node biopsy was performed under ultrasound guidance, followed by an excisional biopsy of the lymph nodes and a regional mastectomy procedure. Excised tissues were submitted for histopathologic examination and evaluated as to whether they were representative of the node. The ultrasound contrast agent was easily visualized with ultrasound leading up to the sentinel lymph nodes. Eight normal lymph nodes (two inguinal, one axillary in two dogs; two inguinal in one dog) were identified and biopsied. Lymphoid tissue was obtained from all biopsy specimens. Samples from four of eight lymph nodes contained both cortical and medullary lymphoid tissue. Contrast-enhanced ultrasound can be successfully used to image and guide minimally invasive biopsy of the normal sentinel lymph nodes draining the mammary glands in healthy dogs. Further work is needed to evaluate whether this technique may be applicable in patients with breast cancer or other conditions warranting evaluation of sentinel lymph nodes in animals.

  12. Ultrasound guided electrochemotherapy for the treatment of a clear cell thymoma in a cat

    Directory of Open Access Journals (Sweden)

    Enrico Pierluigi Spugnini

    2017-03-01

    Full Text Available A twelve-year-old male castrated domestic shorthair cat was presented for rapidly progressing respiratory distress. The cat was depressed, tachypneic and moderately responsive. Ultrasonography showed a mediastinal mass associated with a significant pleural effusion that needed tapping every five to seven days. Ultrasound guided biopsy yielded a diagnosis of clear cell thymoma upon histopathology. After complete staging procedures, the owner elected to treat the cat with electrochemotherapy (ECT using systemic bleomycin. Two sessions of ultrasound guided ECT were performed at two week intervals with trains of biphasic electric pulses applied using needle electrodes until complete coverage of the area was achieved. The treatment was well tolerated and resulted in partial remission (PR. Additional sessions were performed on a monthly basis. The cat is still in PR after fourteen months. ECT resulted in improved local control and should be considered among the available adjuvant treatments in pets carrying visceral tumors.

  13. WE-H-209-00: Carson/Zagzebski Distinguished Lectureship: Image Guided Ultrasound Therapy

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Focused ultrasound has been shown to be the only method that allows noninvasive thermal coagulation of tissues and recently this potential has been explored for image-guided drug delivery. In this presentation, the advances in ultrasound phased array technology for energy delivery, exposure monitoring and control will be discussed. Experimental results from novel multi-frequency transmit/receive arrays will be presented. In addition, the feasibility of fully electronically focused and steered high power arrays with many thousands of transducer elements will be discussed. Finally, some of the recent clinical and preclinical results for the treatment of brain disease will be reviewed. Learning Objectives: Introduce FUS therapy principles and modern techniques Discuss use of FUS for drug delivery Cover the technology required to deliver FUS and monitor therapy Present clinical examples of the uses of these techniques This research was supported by funding from The Canada Research Chair Program, Grants from CIHR and NIH (no. EB003268).; K. Hynynen, Canada Foundation for Innovation; Canadian Institutes of Health Research; Focused Ultrasound Surgery Foundation; Canada Research Chair Program; Natural Sciences and Engineering Research Council of Canada; Ontario Research Fund; National Institutes of Health; Canadian Cancer Society Research Institute; The Weston Brain Institute; Harmonic Medical; Focused Ultrasound Instruments.

  14. The decrease effect of music on anxiety and distress of patients undergoing ultrasound guided core biopsy of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Ae Rang [Dept. of Diagnostic Radiology, St. Carollo General Hospital, Suncheon (Korea, Republic of); Sohn, Seok Joon [Dept. of Preventive Medicine, Chonnam National University Medical School, Chonnam National University Hospital, Gwangju (Korea, Republic of); Moon, Il Bong; Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of)

    2017-06-15

    The aim of this study was to investigate that listening to music reduces the anxiety and distress of the patients who underwent ultrasound guided core biopsy in a clinic. One hundred patients underwent Ultrasound Guided Core Biopsy of the Breast. Each patients was allocated to one of two groups with different methods whether they listened to music or not. The experimental group listening to music are 50 patients and the control group are 50 patients. The difference of VAS anxiety score of pre-test and post-test was signifcant (p<0.001). Compared by the control group, the subjective distress of the patients listening to music such as pain and tension was significant (p<0.001) but nausea and dyspnea was not significant. The objective distress of the patients listening to music was statistically significant (p<0.001). The Differances of systolic blood pressure, diastolic blood pressure, pulse between pre-test and post-test were not signifcant. The results suggest that listening to music reduces the anxiety and distress of the patients who underwent ultrasound guided core biopsy in a clinic.

  15. The decrease effect of music on anxiety and distress of patients undergoing ultrasound guided core biopsy of the breast

    International Nuclear Information System (INIS)

    Woo, Ae Rang; Sohn, Seok Joon; Moon, Il Bong; Dong, Kyung Rae

    2017-01-01

    The aim of this study was to investigate that listening to music reduces the anxiety and distress of the patients who underwent ultrasound guided core biopsy in a clinic. One hundred patients underwent Ultrasound Guided Core Biopsy of the Breast. Each patients was allocated to one of two groups with different methods whether they listened to music or not. The experimental group listening to music are 50 patients and the control group are 50 patients. The difference of VAS anxiety score of pre-test and post-test was signifcant (p<0.001). Compared by the control group, the subjective distress of the patients listening to music such as pain and tension was significant (p<0.001) but nausea and dyspnea was not significant. The objective distress of the patients listening to music was statistically significant (p<0.001). The Differances of systolic blood pressure, diastolic blood pressure, pulse between pre-test and post-test were not signifcant. The results suggest that listening to music reduces the anxiety and distress of the patients who underwent ultrasound guided core biopsy in a clinic

  16. Can ultrasound be helpful in selecting optimal management methods for pregnancies complicated by placental non-trophpblastic tumors?

    Directory of Open Access Journals (Sweden)

    Nabil Abdalla

    2017-06-01

    Full Text Available Placental chorioangioma is the most common subtype of non-trophoblastic placental tumors. Other subtypes are very rare and usually associated with an uneventful course of pregnancy. Most chorioangiomas are small and of no clinical significance. Giant chorioangiomas may be associated with serious fetal and maternal complications. So far, no established ultrasound guidelines are available for the management of placental non-trophoblastic tumors. This may be attributed to the rarity of the disease entity and its different clinical features and complications. In this article, the role of ultrasound findings such as the tumor’s size, vascularity, feeding vessels, amniotic fluid and location of the placenta in the diagnosis, treatment and follow up of these tumors is presented relying on up-todate literature review. Conservative management with serial ultrasound examinations can be an adequate method for monitoring small uncomplicated tumors. Ultrasound-guided procedures such as amnioreduction and cordocentesis can be used for amelioration of complications. Chorioangioma-specific treatment is reserved for complicated cases in the second trimester of pregnancy when prematurity is a matter of concern. Endoscopic laser ablation is indicated when the feeding vessel is superficial and small. Interstitial laser ablation is helpful when the placenta is located in the anterior uterine wall. Ligation of the feeding vessels is preferred when they are large. Alcohol injection should be performed away from the vasculature to prevent toxicity. Microcoils should be inserted as near as possible to the tumor to prevent collateral formation. Ultrasound is also a method of choice for monitoring the effectiveness of these procedures.

  17. Real-time ultrasound-guided spinal anaesthesia: a prospective observational study of a new approach.

    LENUS (Irish Health Repository)

    Conroy, P H

    2013-01-01

    Identification of the subarachnoid space has traditionally been achieved by either a blind landmark-guided approach or using prepuncture ultrasound assistance. To assess the feasibility of performing spinal anaesthesia under real-time ultrasound guidance in routine clinical practice we conducted a single center prospective observational study among patients undergoing lower limb orthopaedic surgery. A spinal needle was inserted unassisted within the ultrasound transducer imaging plane using a paramedian approach (i.e., the operator held the transducer in one hand and the spinal needle in the other). The primary outcome measure was the success rate of CSF acquisition under real-time ultrasound guidance with CSF being located in 97 out of 100 consecutive patients within median three needle passes (IQR 1-6). CSF was not acquired in three patients. Subsequent attempts combining landmark palpation and pre-puncture ultrasound scanning resulted in successful spinal anaesthesia in two of these patients with the third patient requiring general anaesthesia. Median time from spinal needle insertion until intrathecal injection completion was 1.2 minutes (IQR 0.83-4.1) demonstrating the feasibility of this technique in routine clinical practice.

  18. Histopathology of breast cancer after magnetic resonance-guided high-intensity focused ultrasound and radiofrequency ablation

    NARCIS (Netherlands)

    Knuttel, Floor; Waaijer, Laurien; Merckel, LG; van den Bosch, Maurice A A J; Witkamp, Arjen J.; Deckers, Roel; van Diest, Paul J.

    AIMS: Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation and radiofrequency ablation (RFA) are being researched as possible substitutes for surgery in breast cancer patients. The histopathological appearance of ablated tissue has not been studied in great detail. This

  19. Hybrid Photoacoustic/Ultrasound Tomograph for Real-Time Finger Imaging.

    Science.gov (United States)

    Oeri, Milan; Bost, Wolfgang; Sénégond, Nicolas; Tretbar, Steffen; Fournelle, Marc

    2017-10-01

    We report a target-enclosing, hybrid tomograph with a total of 768 elements based on capacitive micromachined ultrasound transducer technology and providing fast, high-resolution 2-D/3-D photoacoustic and ultrasound tomography tailored to finger imaging. A freely programmable ultrasound beamforming platform sampling data at 80 MHz was developed to realize plane wave transmission under multiple angles. A multiplexing unit enables the connection and control of a large number of elements. Fast image reconstruction is provided by GPU processing. The tomograph is composed of four independent and fully automated movable arc-shaped transducers, allowing imaging of all three finger joints. The system benefits from photoacoustics, yielding high optical contrast and enabling visualization of finger vascularization, and ultrasound provides morphologic information on joints and surrounding tissue. A diode-pumped, Q-switched Nd:YAG laser and an optical parametric oscillator are used to broaden the spectrum of emitted wavelengths to provide multispectral imaging. Custom-made optical fiber bundles enable illumination of the region of interest in the plane of acoustic detection. Precision in positioning of the probe in motion is ensured by use of a motor-driven guide slide. The current position of the probe is encoded by the stage and used to relate ultrasound and photoacoustic signals to the corresponding region of interest of the suspicious finger joint. The system is characterized in phantoms and a healthy human finger in vivo. The results obtained promise to provide new opportunities in finger diagnostics and establish photoacoustic/ultrasound-tomography in medical routine. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  1. Hepatic vessel segmentation for 3D planning of liver surgery experimental evaluation of a new fully automatic algorithm.

    Science.gov (United States)

    Conversano, Francesco; Franchini, Roberto; Demitri, Christian; Massoptier, Laurent; Montagna, Francesco; Maffezzoli, Alfonso; Malvasi, Antonio; Casciaro, Sergio

    2011-04-01

    The aim of this study was to identify the optimal parameter configuration of a new algorithm for fully automatic segmentation of hepatic vessels, evaluating its accuracy in view of its use in a computer system for three-dimensional (3D) planning of liver surgery. A phantom reproduction of a human liver with vessels up to the fourth subsegment order, corresponding to a minimum diameter of 0.2 mm, was realized through stereolithography, exploiting a 3D model derived from a real human computed tomographic data set. Algorithm parameter configuration was experimentally optimized, and the maximum achievable segmentation accuracy was quantified for both single two-dimensional slices and 3D reconstruction of the vessel network, through an analytic comparison of the automatic segmentation performed on contrast-enhanced computed tomographic phantom images with actual model features. The optimal algorithm configuration resulted in a vessel detection sensitivity of 100% for vessels > 1 mm in diameter, 50% in the range 0.5 to 1 mm, and 14% in the range 0.2 to 0.5 mm. An average area overlap of 94.9% was obtained between automatically and manually segmented vessel sections, with an average difference of 0.06 mm(2). The average values of corresponding false-positive and false-negative ratios were 7.7% and 2.3%, respectively. A robust and accurate algorithm for automatic extraction of the hepatic vessel tree from contrast-enhanced computed tomographic volume images was proposed and experimentally assessed on a liver model, showing unprecedented sensitivity in vessel delineation. This automatic segmentation algorithm is promising for supporting liver surgery planning and for guiding intraoperative resections. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  2. Propagation of ultrasonic guided waves in an acrylic plate as a cortical-bone-mimicking phantom

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kang Il [Kangwon National University, Chuncheon (Korea, Republic of); Choi, Bok Kyoung [Maritime Security Research Center, KIOST, Ansan (Korea, Republic of)

    2014-12-15

    The present study aims to investigate the propagation of ultrasonic guided waves in an acrylic plate as a cortical-bone-mimicking phantom. The velocities of the guided waves in a 5-mm-thick acrylic plate were measured by using the axial transmission technique. A pure A0 Lamb mode could be successfully launched in the 5-mm-thick acrylic plate through a time reversal process of Lamb waves, consistent with the fact that the time reversal process can automatically compensate for the dispersive nature of Lamb waves. The experimental velocities of the slow guided wave (SGW) and the time-reversed Lamb wave were found to be in reasonable agreement with the theoretical group velocity of the A0 Lamb mode, suggesting that both the SGW and the time-reversed Lamb wave excited in the 5-mm-thick acrylic plate correspond to the A0 Lamb mode. These results suggest that the time reversal process of Lamb waves can be usefully applied to noninvasive characterization of long cortical bones.

  3. Propagation of ultrasonic guided waves in an acrylic plate as a cortical-bone-mimicking phantom

    International Nuclear Information System (INIS)

    Lee, Kang Il; Choi, Bok Kyoung

    2014-01-01

    The present study aims to investigate the propagation of ultrasonic guided waves in an acrylic plate as a cortical-bone-mimicking phantom. The velocities of the guided waves in a 5-mm-thick acrylic plate were measured by using the axial transmission technique. A pure A0 Lamb mode could be successfully launched in the 5-mm-thick acrylic plate through a time reversal process of Lamb waves, consistent with the fact that the time reversal process can automatically compensate for the dispersive nature of Lamb waves. The experimental velocities of the slow guided wave (SGW) and the time-reversed Lamb wave were found to be in reasonable agreement with the theoretical group velocity of the A0 Lamb mode, suggesting that both the SGW and the time-reversed Lamb wave excited in the 5-mm-thick acrylic plate correspond to the A0 Lamb mode. These results suggest that the time reversal process of Lamb waves can be usefully applied to noninvasive characterization of long cortical bones.

  4. ultrasound-guided shoulder arthrogram injection

    African Journals Online (AJOL)

    2008-10-15

    Oct 15, 2008 ... Using an aseptic technique and without moving the ultrasound transducer from the desired transverse plane, the needle is advanced into the joint space through the rotator cuff interval, using real-time ultrasound guidance (Fig.2). The needle is inserted into the shoulder approximately midway between the ...

  5. Distal infrared thermography and skin temperature after ultrasound-guided interscalene brachial plexus block

    DEFF Research Database (Denmark)

    Asghar, Semera; Bjerregaard, Lars S; Lundstrøm, Lars H

    2014-01-01

    thermographic imaging of the hand before and at 1 min intervals for 30 min after an ultrasound-guided IBPB with 20 ml ropivacaine 7.5 mg ml. Cooling of both hands was performed to standardise measurements. MAIN OUTCOME MEASURES: Thermographic changes in skin temperature on the dorsum of the hand. RESULTS: Forty...

  6. Phantom evaluation of a commercially available three modality image guided radiation therapy system

    International Nuclear Information System (INIS)

    Ploquin, Nicolas; Rangel, Alejandra; Dunscombe, Peter

    2008-01-01

    The authors describe a detailed evaluation of the capabilities of imaging and image registration systems available with Varian linear accelerators for image guided radiation therapy (IGRT). Specifically, they present modulation transfer function curves for megavoltage planar, kilovoltage (kV) planar, and cone beam computed tomography imaging systems and compare these with conventional computed tomography. While kV planar imaging displayed the highest spatial resolution, all IGRT imaging techniques were assessed as adequate for their intended purpose. They have also characterized the image registration software available for use in conjunction with these imaging systems through a comprehensive phantom study involving translations in three orthogonal directions. All combinations of imaging systems and image registration software were found to be accurate, although the planar kV imaging system with automatic registration was generally superior, with both accuracy and precision of the order of 1 mm, under the conditions tested. Based on their phantom study, the attainable accuracy for rigid body translations using any of the features available with Varian equipment will more likely be limited by the resolution of the couch readouts than by inherent limitations in the imaging systems and image registration software. Overall, the accuracy and precision of currently available IGRT technology exceed published experience with the accuracy and precision of contouring for planning.

  7. Delphi Method Validation of a Procedural Performance Checklist for Insertion of an Ultrasound-Guided Internal Jugular Central Line.

    Science.gov (United States)

    Hartman, Nicholas; Wittler, Mary; Askew, Kim; Manthey, David

    2016-01-01

    Placement of ultrasound-guided central lines is a critical skill for physicians in several specialties. Improving the quality of care delivered surrounding this procedure demands rigorous measurement of competency, and validated tools to assess performance are essential. Using the iterative, modified Delphi technique and experts in multiple disciplines across the United States, the study team created a 30-item checklist designed to assess competency in the placement of ultrasound-guided internal jugular central lines. Cronbach α was .94, indicating an excellent degree of internal consistency. Further validation of this checklist will require its implementation in simulated and clinical environments. © The Author(s) 2014.

  8. In-service ultrasonic inspection of nuclear reactor pressure vessels

    International Nuclear Information System (INIS)

    Prepechal, J.; Sulc, J.

    1982-01-01

    Ultrasonic tests of pressure vessels for WWER 440 reactors, type 213 V, are carried out partly manually and partly by test equipment. The inner surface of the pressure vessel is tested using device REACTORTEST TRC which is fully mobile. The outer surface of the cylindrical parts and bottoms of the body is tested using handling equipment permanently in-built under the pressure vessel and dismountable testing heads. A set of these heads may be used for two reactor units. The testing equipment REACTORTEST TRC is equipped with a TRC 800 ultrasound device. The equipment for testing the outer surface of the vessel operates with the UDAR 16 ultrasound apparatus to which may be simultaneously connected 10 ultrasound probes and six probes for acoustic feedback. The whole system of ultrasonic tests makes possible a first-rate and reliable volume control of the whole pressure vessel and all points where cracks may originate and grow. (Z.M.)

  9. Ultrasound guided injection of dexamethasone versus placebo for treatment of plantar fasciitis: protocol for a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Gilheany Mark F

    2010-07-01

    Full Text Available Abstract Background Plantar fasciitis is the most commonly reported cause of chronic pain beneath the heel. Management of this condition commonly involves the use of corticosteroid injection in cases where less invasive treatments have failed. However, despite widespread use, only two randomised trials have tested the effect of this treatment in comparison to placebo. These trials currently offer the best available evidence by which to guide clinical practice, though both were limited by methodological issues such as insufficient statistical power. Therefore, the aim of this randomised trial is to compare the effect of ultrasound-guided corticosteroid injection versus placebo for treatment of plantar fasciitis. Methods The trial will be conducted at the La Trobe University Podiatry Clinic and will recruit 80 community-dwelling participants. Diagnostic ultrasound will be used to diagnose plantar fasciitis and participants will be required to meet a range of selection criteria. Participants will be randomly allocated to one of two treatment arms: (i ultrasound-guided injection of the plantar fascia with 1 mL of 4 mg/mL dexamethasone sodium phosphate (experimental group, or (ii ultrasound-guided injection of the plantar fascia with 1 mL normal saline (control group. Blinding will be applied to participants and the investigator performing procedures, measuring outcomes and analysing data. Primary outcomes will be pain measured by the Foot Health Status Questionnaire and plantar fascia thickness measured by ultrasound at 4, 8 and 12 weeks. All data analyses will be conducted on an intention-to-treat basis. Conclusion This will be a randomised trial investigating the effect of dexamethasone injection on pre-specified treatment outcomes in people with plantar fasciitis. Within the parameters of this protocol, the trial findings will be used to make evidence-based recommendations regarding the use of corticosteroid injection for treatment of this

  10. Standard Guide for Conducting Supplemental Surveillance Tests for Nuclear Power Reactor Vessels, E 706 (IH)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide discusses test procedures that can be used in conjunction with, but not as alternatives to, those required by Practices E185 and E2215 for the surveillance of nuclear reactor vessels. The supplemental mechanical property tests outlined permit the acquisition of additional information on radiation-induced changes in fracture toughness, notch ductility, and yield strength properties of the reactor vessel steels. 1.2 This guide provides recommendations for the preparation of test specimens for irradiation, and identifies special precautions and requirements for reactor surveillance operations and postirradiation test planning. Guidance on data reduction and computational procedures is also given. Reference is made to other ASTM test methods for the physical conduct of specimen tests and for raw data acquisition.

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Because ultrasound provides real-time images, it also can be used to guide procedures such as needle ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ... bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the prostate gland because ...

  14. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... size, shape and consistency (whether the object is solid or filled with fluid). In medicine, ultrasound is ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  15. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ... structure and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound ...

  16. Image-guided ultrasound phased arrays are a disruptive technology for non-invasive therapy.

    Science.gov (United States)

    Hynynen, Kullervo; Jones, Ryan M

    2016-09-07

    Focused ultrasound offers a non-invasive way of depositing acoustic energy deep into the body, which can be harnessed for a broad spectrum of therapeutic purposes, including tissue ablation, the targeting of therapeutic agents, and stem cell delivery. Phased array transducers enable electronic control over the beam geometry and direction, and can be tailored to provide optimal energy deposition patterns for a given therapeutic application. Their use in combination with modern medical imaging for therapy guidance allows precise targeting, online monitoring, and post-treatment evaluation of the ultrasound-mediated bioeffects. In the past there have been some technical obstacles hindering the construction of large aperture, high-power, densely-populated phased arrays and, as a result, they have not been fully exploited for therapy delivery to date. However, recent research has made the construction of such arrays feasible, and it is expected that their continued development will both greatly improve the safety and efficacy of existing ultrasound therapies as well as enable treatments that are not currently possible with existing technology. This review will summarize the basic principles, current statures, and future potential of image-guided ultrasound phased arrays for therapy.

  17. Technical guide to evaluate upper limb joints (shoulder, elbow and wrist) by ultrasound

    International Nuclear Information System (INIS)

    Obregon Baez, Luis Rafael

    2014-01-01

    A guideline to follow is offered to radiologists and residents of radiology service of medical imaging, when evaluating by ultrasound the shoulder joints, elbow, wrist. The importance to performing of musculoskeletal ultrasound by its pathology variable is established. The use of appropriate equipment and effective application of the techniques exposed of echography exploration have made enable the valuation of many pathologies with high sensitivity and specificity. The echography has been the musculoskeletal imaging technique that more rapidly has evolved. Currently, this technique has been replaced by magnetic resonance imaging in various clinical fields and also serves as a complement to other techniques. Exposed techniques have been of great benefit for radiologists medical and residents, obtaining with its use a quick guide for the realization of upper limb musculoskeletal ultrasounds. The appropriate and easy techniques are better known for the evaluation of these structures, and so document both sports injuries, as joint and rheumatic diseases [es

  18. Vessel size measurements in angiograms: Manual measurements

    International Nuclear Information System (INIS)

    Hoffmann, Kenneth R.; Dmochowski, Jacek; Nazareth, Daryl P.; Miskolczi, Laszlo; Nemes, Balazs; Gopal, Anant; Wang Zhou; Rudin, Stephen; Bednarek, Daniel R.

    2003-01-01

    Vessel size measurement is perhaps the most often performed quantitative analysis in diagnostic and interventional angiography. Although automated vessel sizing techniques are generally considered to have good accuracy and precision, we have observed that clinicians rarely use these techniques in standard clinical practice, choosing to indicate the edges of vessels and catheters to determine sizes and calibrate magnifications, i.e., manual measurements. Thus, we undertook an investigation of the accuracy and precision of vessel sizes calculated from manually indicated edges of vessels. Manual measurements were performed by three neuroradiologists and three physicists. Vessel sizes ranged from 0.1-3.0 mm in simulation studies and 0.3-6.4 mm in phantom studies. Simulation resolution functions had full-widths-at-half-maximum (FWHM) ranging from 0.0 to 0.5 mm. Phantom studies were performed with 4.5 in., 6 in., 9 in., and 12 in. image intensifier modes, magnification factor = 1, with and without zooming. The accuracy and reproducibility of the measurements ranged from 0.1 to 0.2 mm, depending on vessel size, resolution, and pixel size, and zoom. These results indicate that manual measurements may have accuracies comparable to automated techniques for vessels with sizes greater than 1 mm, but that automated techniques which take into account the resolution function should be used for vessels with sizes smaller than 1 mm

  19. A quick guide to API 510 certified pressure vessel inspector syllabus example questions and worked answers

    CERN Document Server

    Matthews, Clifford

    2010-01-01

    The API Individual Certification Programs (ICPs) are well established worldwide in the oil, gas, and petroleum industries. This Quick Guide is unique in providing simple, accessible and well-structured guidance for anyone studying the API 510 Certified Pressure Vessel Inspector syllabus by summarizing and helping them through the syllabus and providing multiple example questions and worked answers.Technical standards are referenced from the API 'body of knowledge' for the examination, i.e. API 510 Pressure vessel inspection, alteration, rerating; API 572 Pressure vessel inspection; API

  20. Derivation of a Performance Checklist for Ultrasound-Guided Arthrocentesis Using the Modified Delphi Method.

    Science.gov (United States)

    Kunz, Derek; Pariyadath, Manoj; Wittler, Mary; Askew, Kim; Manthey, David; Hartman, Nicholas

    2017-06-01

    Arthrocentesis is an important skill for physicians in multiple specialties. Recent studies indicate a superior safety and performance profile for this procedure using ultrasound guidance for needle placement, and improving quality of care requires a valid measurement of competency using this modality. We endeavored to create a validated tool to assess the performance of this procedure using the modified Delphi technique and experts in multiple disciplines across the United States. We derived a 22-item checklist designed to assess competency for the completion of ultrasound-guided arthrocentesis, which demonstrated a Cronbach's alpha of 0.89, indicating an excellent degree of internal consistency. Although we were able to demonstrate content validity for this tool, further validity evidence should be acquired after the tool is used and studied in clinical and simulated contexts. © 2017 by the American Institute of Ultrasound in Medicine.