  1. Automatic Ultrasound Scanning

    DEFF Research Database (Denmark)

    Moshavegh, Ramin

    on the user adjustments on the scanner interface to optimize the scan settings. This explains the huge interest in the subject of this PhD project entitled “AUTOMATIC ULTRASOUND SCANNING”. The key goals of the project have been to develop automated techniques to minimize the unnecessary settings...... on the scanners, and to improve the computer-aided diagnosis (CAD) in ultrasound by introducing new quantitative measures. Thus, four major issues concerning automation of the medical ultrasound are addressed in this PhD project. They touch upon gain adjustments in ultrasound, automatic synthetic aperture image...

  2. Practical recommendations for performing ultrasound scanning in the urological and andrological fields.

    Science.gov (United States)

    Martino, Pasquale; Galosi, Andrea Benedetto; Bitelli, Marco; Consonni, Paolo; Fiorini, Fulvio; Granata, Antonio; Gunelli, Roberta; Liguori, Giovanni; Palazzo, Silvano; Pavan, Nicola; Scattoni, Vincenzo; Virgili, Guido

    2014-03-28

    US scanning has been defined as the urologist's stethoscope. These recommendations have been drawn up with the aim of ensuring minimum standards of excellence for ultrasound imaging in urological and andrological practice. A series of essential recommendations are made, to be followed during ultrasound investigations in kidney, prostate, bladder, scrotal and penile diseases. Members of the Imaging Working Group of the Italian Society of Urology (SIU) in collaboration with the Italian Society of Ultrasound in Urology, Andrology and Nephrology (SIEUN) identified expert Urologists, Andrologists, Nephrologists and Radiologists. The recommendations are based on review of the literature, previously published recommendations, books and the opinions of the experts. The final document was reviewed by national experts, including members of the Italian Society of Radiology. Recommendations are listed in 5 chapters, focused on: kidney, bladder, prostate and seminal vesicles, scrotum and testis, penis, including penile echo-doppler. In each chapter clear definitions are made of: indications, technological standards of the devices, the method of performance of the investigation. The findings to be reported are described and discussed, and examples of final reports for each organ are included. In the tables, the ultrasound features of the principal male uro-genital diseases are summarized. Diagnostic accuracy and second level investigations are considered. Ultrasound is an integral part of the diagnosis and follow-up of diseases of the urinary system and male genitals in patients of all ages, in both the hospital and outpatient setting. These recommendations are dedicated to enhancing communication and evidence-based medicine in an inter- and multi-disciplinary approach. The ability to perform and interpret ultrasound imaging correctly has become an integral part of clinical practice in uro-andrology, but intra and inter-observer variability is a well known limitation. These

  3. Practical recommendations for performing ultrasound scanning in the urological and andrological fields

    Directory of Open Access Journals (Sweden)

    Pasquale Martino

    2014-03-01

    Full Text Available Aim: US scanning has been defined as the urologist’s stethoscope. These recommendations have been drawn up with the aim of ensuring minimum standards of excellence for ultrasound imaging in urological and andrological practice. A series of essential recommendations are made, to be followed during ultrasound investigations in kidney, prostate, bladder, scrotal and penile diseases. Methods: Members of the Imaging Working Group of the Italian Society of Urology (SIU in collaboration with the Italian Society of Ultrasound in Urology, Andrology and Nephrology (SIEUN identified expert Urologists, Andrologists, Nephrologists and Radiologists. The recommendations are based on review of the literature, previously published recommendations, books and the opinions of the experts. The final document was reviewed by national experts, including members of the Italian Society of Radiology. Results: Recommendations are listed in 5 chapters, focused on: kidney, bladder, prostate and seminal vesicles, scrotum and testis, penis, including penile echo-doppler. In each chapter clear definitions are made of: indications, technological standards of the devices, the method of performance of the investigation. The findings to be reported are described and discussed, and examples of final reports for each organ are included. In the tables, the ultrasound features of the principal male uro-genital diseases are summarized. Diagnostic accuracy and second level investigations are considered. Conclusions: Ultrasound is an integral part of the diagnosis and follow-up of diseases of the urinary system and male genitals in patients of all ages, in both the hospital and outpatient setting. These recommendations are dedicated to enhancing communication and evidence-based medicine in an inter- and multi-disciplinary approach. The ability to perform and interpret ultrasound imaging correctly has become an integral part of clinical practice in uro-andrology, but intra and inter

  4. Automatic Segmentation of Vessels in In-Vivo Ultrasound Scans

    DEFF Research Database (Denmark)

    Tamimi-Sarnikowski, Philip; Brink-Kjær, Andreas; Moshavegh, Ramin

    2017-01-01

    presents a fully automatic segmentation algorithm, for robustly segmenting the vessel lumen in longitudinal B-mode ultrasound images. The automatic segmentation is performed using a combination of B-mode and power Doppler images. The proposed algorithm includes a series of preprocessing steps, and performs......Ultrasound has become highly popular to monitor atherosclerosis, by scanning the carotid artery. The screening involves measuring the thickness of the vessel wall and diameter of the lumen. An automatic segmentation of the vessel lumen, can enable the determination of lumen diameter. This paper...... a vessel segmentation by use of the marker-controlled watershed transform. The ultrasound images used in the study were acquired using the bk3000 ultrasound scanner (BK Ultrasound, Herlev, Denmark) with two transducers ”8L2 Linear” and ”10L2w Wide Linear” (BK Ultrasound, Herlev, Denmark). The algorithm...

  5. A multipoint feedback control system for scanned focussed ultrasound hyperthermia

    International Nuclear Information System (INIS)

    Johnson, C.; Kress, R.; Roemer, R.; Hynynen, K.

    1987-01-01

    A multipoint feedback control system has been developed and tested for use with a scanned focussed ultrasound hyperthermia system. Extensive in-vivo tests (using a perfused organ model) have been made to evaluate the basic performance characteristics of the feedback control scheme for control of temperature in perfused media. The results of these tests are presented and compared with the predictions of a simulation routine. The control scheme was also tested in vivo using dogs' thighs and kidneys. Thigh experiments show the control scheme responds well to the affects of vasodilation and is able to maintain the targeted temperatures. In kidney experiments, where the rate of perfusion was controllable, the power adjusting algorithm successfully maintained uniform temperature distributions across regions of varying rates of perfusion. As a conclusion, the results show that this multipoint feedback controller scheme induces uniform temperature distributions when used with scanned focussed ultrasound systems

  6. Experience and use of ultrasound scan for fetal evaluation among ...

    African Journals Online (AJOL)

    Experience and use of ultrasound scan for fetal evaluation among obstetricians in an African population. ... Annals of Biomedical Sciences ... scan held in May 2014 at the University of Benin Teaching Hospital were recruited for the study.

  7. Doppler ultrasound scan during normal gestation: umbilical circulation

    International Nuclear Information System (INIS)

    Ruiz, T.; Sabate, J.; Martinez-Benavides, M. M.; Sanchez-Ramos, J.

    2002-01-01

    To determine normal umbilical circulation patterns by means of Doppler ultrasound scan in a healthy gestating population without risk factors and with normal perinatal results, and to evaluate any occurring modifications relative to gestational age by obtaining records kept during pregnancy. One hundred and sixteen pregnant women carrying a single fetus have been studied. These women had no risk factors, with both clinical and analytical controls, as well as ultrasound scans, all being normal. There were performed a total of 193 Doppler ultrasound scans between weeks 15 and 41 of gestation, with blood-flow analysis in the arteries and vein of the umbilical cord. The obtained information was correlated with parameters that evaluate fetal well-being (fetal monitoring and/or oxytocin test) and perinatal result (delivery type, birth weight, Apgar score). Statistical analysis was performed with the programs SPSS 6.0.1 for Windows and EPIINFO 6.0.4. With pulsed Doppler, the umbilical artery in all cases demonstrated a biphasic morphology with systolic and diastolic components and without retrograde blood flow. As the gestation period increased, there was observed a progressive decrease in resistance along with an increase in blood-flow velocity during the diastolic phase. The Doppler ultrasound scan is a non-invasive method that permits the hemodynamic study of umbilical blood circulation. A knowledge of normal blood-flow signal morphology, as well as of the normal values for Doppler indices in relation to gestational age would permit us to utilize this method in high-risk pregnancies. (Author) 30 refs

  8. Spatial Angular Compounding Technique for H-Scan Ultrasound Imaging.

    Science.gov (United States)

    Khairalseed, Mawia; Xiong, Fangyuan; Kim, Jung-Whan; Mattrey, Robert F; Parker, Kevin J; Hoyt, Kenneth

    2018-01-01

    H-Scan is a new ultrasound imaging technique that relies on matching a model of pulse-echo formation to the mathematics of a class of Gaussian-weighted Hermite polynomials. This technique may be beneficial in the measurement of relative scatterer sizes and in cancer therapy, particularly for early response to drug treatment. Because current H-scan techniques use focused ultrasound data acquisitions, spatial resolution degrades away from the focal region and inherently affects relative scatterer size estimation. Although the resolution of ultrasound plane wave imaging can be inferior to that of traditional focused ultrasound approaches, the former exhibits a homogeneous spatial resolution throughout the image plane. The purpose of this study was to implement H-scan using plane wave imaging and investigate the impact of spatial angular compounding on H-scan image quality. Parallel convolution filters using two different Gaussian-weighted Hermite polynomials that describe ultrasound scattering events are applied to the radiofrequency data. The H-scan processing is done on each radiofrequency image plane before averaging to get the angular compounded image. The relative strength from each convolution is color-coded to represent relative scatterer size. Given results from a series of phantom materials, H-scan imaging with spatial angular compounding more accurately reflects the true scatterer size caused by reductions in the system point spread function and improved signal-to-noise ratio. Preliminary in vivo H-scan imaging of tumor-bearing animals suggests this modality may be useful for monitoring early response to chemotherapeutic treatment. Overall, H-scan imaging using ultrasound plane waves and spatial angular compounding is a promising approach for visualizing the relative size and distribution of acoustic scattering sources. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  9. Ultrasound scan in the diagnosis of neonatal renal candidiasis

    International Nuclear Information System (INIS)

    Muro, D.; Sanguesa, C.; Torres, D.; Berbel, O.; Andres, V.

    2003-01-01

    To describe the most pertinent echographic findings regarding systemic and renal candidiasis in high-risk neonates. Echographic findings and clinical histories of 40 neonates in the neonatal intensive care unit were retrospectively analyzed. Thirty-eight presented systemic candidiasis with renal participation, while two showed only renal candidiasis. Ultrasound scans were performed using 7.5 MHz probes. Alterations in renal echo structure, presence of echogenic material without acoustic shadowing in the excretory system (mycetoma), presence of lithiasis, pyonephrosis and associated renal malformations were all evaluated. Ten patients presented renal alterations in ultrasound scan. Six children had originally shown increased eye-catching in the renal parenchyma which was resolved after medical treatment. Four children presented renal mycetoma, and in two there were renal malformations. Both of these exhibited a profile for pyonephrosis. One patient with renal mycetoma without urological abnormalities developed a lithiasis. Surgical intervention was unnecessary in all cases. The most common echographic findings in immature high-risk low-weight patients with systemic and renal candidiasis were alterations in the eye-catching of renal parenchyma and the presence of mycetoma. (Author) 22 refs

  10. Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting.

    Science.gov (United States)

    Kim, Chunwoo; Chang, Doyoung; Petrisor, Doru; Chirikjian, Gregory; Han, Misop; Stoianovici, Dan

    2013-06-01

    Image-to-robot registration is a typical step for robotic image-guided interventions. If the imaging device uses a portable imaging probe that is held by a robot, this registration is constant and has been commonly named probe calibration. The same applies to probes tracked by a position measurement device. We report a calibration method for 2-D ultrasound probes using robotic manipulation and a planar calibration rig. Moreover, a needle guide that is attached to the probe is also calibrated for ultrasound-guided needle targeting. The method is applied to a transrectal ultrasound (TRUS) probe for robot-assisted prostate biopsy. Validation experiments include TRUS-guided needle targeting accuracy tests. This paper outlines the entire process from the calibration to image-guided targeting. Freehand TRUS-guided prostate biopsy is the primary method of diagnosing prostate cancer, with over 1.2 million procedures performed annually in the U.S. alone. However, freehand biopsy is a highly challenging procedure with subjective quality control. As such, biopsy devices are emerging to assist the physician. Here, we present a method that uses robotic TRUS manipulation. A 2-D TRUS probe is supported by a 4-degree-of-freedom robot. The robot performs ultrasound scanning, enabling 3-D reconstructions. Based on the images, the robot orients a needle guide on target for biopsy. The biopsy is acquired manually through the guide. In vitro tests showed that the 3-D images were geometrically accurate, and an image-based needle targeting accuracy was 1.55 mm. These validate the probe calibration presented and the overall robotic system for needle targeting. Targeting accuracy is sufficient for targeting small, clinically significant prostatic cancer lesions, but actual in vivo targeting will include additional error components that will have to be determined.

  11. Ultrasound detection of pneumothorax compared with chest X-ray and computed tomography scan.

    Science.gov (United States)

    Nagarsheth, Khanjan; Kurek, Stanley

    2011-04-01

    Pneumothorax after trauma can be a life threatening injury and its care requires expeditious and accurate diagnosis and possible intervention. We performed a prospective, single blinded study with convenience sampling at a Level I trauma center comparing thoracic ultrasound with chest X-ray and CT scan in the detection of traumatic pneumothorax. Trauma patients that received a thoracic ultrasound, chest X-ray, and chest CT scan were included in the study. The chest X-rays were read by a radiologist who was blinded to the thoracic ultrasound results. Then both were compared with CT scan results. One hundred and twenty-five patients had a thoracic ultrasound performed in the 24-month period. Forty-six patients were excluded from the study due to lack of either a chest X-ray or chest CT scan. Of the remaining 79 patients there were 22 positive pneumothorax found by CT and of those 18 (82%) were found on ultrasound and 7 (32%) were found on chest X-ray. The sensitivity of thoracic ultrasound was found to be 81.8 per cent and the specificity was found to be 100 per cent. The sensitivity of chest X-ray was found to be 31.8 per cent and again the specificity was found to be 100 per cent. The negative predictive value of thoracic ultrasound for pneumothorax was 0.934 and the negative predictive value for chest X-ray for pneumothorax was found to be 0.792. We advocate the use of chest ultrasound for detection of pneumothorax in trauma patients.

  12. Acute pyelonephritis in pediatric age: comparative study between power Doppler ultrasound scan and DMSA

    International Nuclear Information System (INIS)

    Muro, M. D.; Sanguesa, C.; Otero, M. C.; Piqueras, A. I.; Lloret, M. T.

    2002-01-01

    To evaluate the usefulness of power Doppler (PD) Ultrasound Scan in the study of acute pyelonephritis (APN). To compare ultrasound scan results with those obtained with renal gammagraphy (DMSA). To relate the findings to the clinical criteria and to determine the presence of vesicoureteral reflux (VUR) in the serial micturition cystography (SMC). Prospective study of 92 patients (ages between 1 month and 10 years) with suspected clinical PNA. All children were initially subjected to PD ultrasound scan and DMSA. Those under 3 years old were also subjected to SMC for the study of VUR. PNA in the PD ultrasound scan was manifested by decrease in vascularisation and in the DMSA by decrease in caption in the affected zones. 87 renal units (RU) with PNA foci were detected. Conformity between the PD ultrasound scan and DMSA was 157 RU (92%): 52 positives, 22 negatives with PNA and 83 normal RU. The sensitivities of PD and DMSA were 65.5% and 69.0%. 51 SMC were performed, with VUR being detected in 18 (13 bilateral and 5 unilateral), in which the sensitivities of PD and DMSA were 65.5% and 69.0%. 51 SMC were performed, with VUR being detected in 18 (13 bilateral and 5 unilateral), in which the sensitivities of PD and DMSA were 80% and 85%, respectively. Mode B ultrasound scan and PD can replace DMSA in the initial study of PPNA. It is non-invasive, simple, economical and just as reliable as DMSA in expert hands. it can also postpone by up to 6 months the need to perform DMSA for detection of permanent renal damage. (Author) 22 refs

  13. Prediction of trabecular bone qualitative properties using scanning quantitative ultrasound

    Science.gov (United States)

    Qin, Yi-Xian; Lin, Wei; Mittra, Erik; Xia, Yi; Cheng, Jiqi; Judex, Stefan; Rubin, Clint; Müller, Ralph

    2013-11-01

    Microgravity induced bone loss represents a critical health problem in astronauts, particularly occurred in weight-supporting skeleton, which leads to osteopenia and increase of fracture risk. Lack of suitable evaluation modality makes it difficult for monitoring skeletal status in long term space mission and increases potential risk of complication. Such disuse osteopenia and osteoporosis compromise trabecular bone density, and architectural and mechanical properties. While X-ray based imaging would not be practical in space, quantitative ultrasound may provide advantages to characterize bone density and strength through wave propagation in complex trabecular structure. This study used a scanning confocal acoustic diagnostic and navigation system (SCAN) to evaluate trabecular bone quality in 60 cubic trabecular samples harvested from adult sheep. Ultrasound image based SCAN measurements in structural and strength properties were validated by μCT and compressive mechanical testing. This result indicated a moderately strong negative correlations observed between broadband ultrasonic attenuation (BUA) and μCT-determined bone volume fraction (BV/TV, R2=0.53). Strong correlations were observed between ultrasound velocity (UV) and bone's mechanical strength and structural parameters, i.e., bulk Young's modulus (R2=0.67) and BV/TV (R2=0.85). The predictions for bone density and mechanical strength were significantly improved by using a linear combination of both BUA and UV, yielding R2=0.92 for BV/TV and R2=0.71 for bulk Young's modulus. These results imply that quantitative ultrasound can characterize trabecular structural and mechanical properties through measurements of particular ultrasound parameters, and potentially provide an excellent estimation for bone's structural integrity.

  14. Performance of the SRK/T formula using A-Scan ultrasound biometry after phacoemulsification in eyes with short and long axial lengths.

    Science.gov (United States)

    Karabela, Yunus; Eliacik, Mustafa; Kaya, Faruk

    2016-07-08

    The SRK/T formula is one of the third generation IOL calculation formulas. The purpose of this study was to evaluate the performance of the SRK/T formula in predicting a target refraction ±1.0D in short and long eyes using ultrasound biometry after phacoemulsification. The present study was a retrospective analysis, which included 38 eyes with an AL ultrasound biometry and SRK/T formula was used for IOL calculation. Three different IOLs were implanted in the capsular bag. The prediction error was defined as the difference between the achieved postoperative refraction, and attempted predicted target refraction. Statistical analysis was performed with SPSS V21. In short ALs, the mean age was 65.13 ± 9.49 year, the mean AL was 21.55 ± 0.45 mm, the mean K1 and K2 were 45.76 ± 1.77D and 46.09 ± 1.61D, the mean IOL power was 23.96 ± 1.92D, the mean attempted (predicted) value was 0.07 ± 0.26D, the mean achieved value was 0.07 ± 0.63 D, the mean PE was 0.01 ± 0.60D, and the MAE was 0.51 ± 0.31D. A significant positive relationship with AL and K1, K2, IOL power and a strong negative relationship with PE and achieved postoperative was found. In long ALs, the mean age was 64.05 ± 7.31 year, the mean AL was 25.77 ± 1.64 mm, the mean K1 and K2 were 42.20 ± 1.57D and 42.17 ± 1.68D, the mean IOL power was 15.79 ± 5.17D, the mean attempted value was -0.434 ± 0.315D, the mean achieved value was -0.42 ± 0.96D, the mean PE was -0.004 ± 0.93D, the MAE was 0.68 ± 0.62D. A significant positive relationship with AL and K1, K2 and a significant positive relationship with PE and achieved value, otherwise a negative relationship with AL and IOL power was found. There was a little tendency towards hyperopic for short ALs and myopic for long ALs. The majority of eyes (94.74 %) for short ALs and (70.97 %) for long ALs were within ±1 D of the predicted refractive error. No significant relationship

  15. Sustained effect of simulation-based ultrasound training on clinical performance

    DEFF Research Database (Denmark)

    Tolsgaard, M G; Ringsted, C; Dreisler, E

    2015-01-01

    on a virtual-reality transvaginal ultrasound simulator until an expert performance level was attained followed by training on a pelvic mannequin. After two months of clinical training, one transvaginal ultrasound scan was recorded for assessment of participants' clinical performance. Two blinded ultrasound...

  16. Cognitive load predicts point-of-care ultrasound simulator performance.

    Science.gov (United States)

    Aldekhyl, Sara; Cavalcanti, Rodrigo B; Naismith, Laura M

    2018-02-01

    The ability to maintain good performance with low cognitive load is an important marker of expertise. Incorporating cognitive load measurements in the context of simulation training may help to inform judgements of competence. This exploratory study investigated relationships between demographic markers of expertise, cognitive load measures, and simulator performance in the context of point-of-care ultrasonography. Twenty-nine medical trainees and clinicians at the University of Toronto with a range of clinical ultrasound experience were recruited. Participants answered a demographic questionnaire then used an ultrasound simulator to perform targeted scanning tasks based on clinical vignettes. Participants were scored on their ability to both acquire and interpret ultrasound images. Cognitive load measures included participant self-report, eye-based physiological indices, and behavioural measures. Data were analyzed using a multilevel linear modelling approach, wherein observations were clustered by participants. Experienced participants outperformed novice participants on ultrasound image acquisition. Ultrasound image interpretation was comparable between the two groups. Ultrasound image acquisition performance was predicted by level of training, prior ultrasound training, and cognitive load. There was significant convergence between cognitive load measurement techniques. A marginal model of ultrasound image acquisition performance including prior ultrasound training and cognitive load as fixed effects provided the best overall fit for the observed data. In this proof-of-principle study, the combination of demographic and cognitive load measures provided more sensitive metrics to predict ultrasound simulator performance. Performance assessments which include cognitive load can help differentiate between levels of expertise in simulation environments, and may serve as better predictors of skill transfer to clinical practice.

  17. Chest wall segmentation in automated 3D breast ultrasound scans.

    Science.gov (United States)

    Tan, Tao; Platel, Bram; Mann, Ritse M; Huisman, Henkjan; Karssemeijer, Nico

    2013-12-01

    In this paper, we present an automatic method to segment the chest wall in automated 3D breast ultrasound images. Determining the location of the chest wall in automated 3D breast ultrasound images is necessary in computer-aided detection systems to remove automatically detected cancer candidates beyond the chest wall and it can be of great help for inter- and intra-modal image registration. We show that the visible part of the chest wall in an automated 3D breast ultrasound image can be accurately modeled by a cylinder. We fit the surface of our cylinder model to a set of automatically detected rib-surface points. The detection of the rib-surface points is done by a classifier using features representing local image intensity patterns and presence of rib shadows. Due to attenuation of the ultrasound signal, a clear shadow is visible behind the ribs. Evaluation of our segmentation method is done by computing the distance of manually annotated rib points to the surface of the automatically detected chest wall. We examined the performance on images obtained with the two most common 3D breast ultrasound devices in the market. In a dataset of 142 images, the average mean distance of the annotated points to the segmented chest wall was 5.59 ± 3.08 mm. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Is there a relationship between ultrasound scanning ability (sonography) and visuospatial perception or psychomotor ability?

    Science.gov (United States)

    Hagen, Suzanne; Gallagher, Helen

    2016-01-01

    Background Competent sonography is thought to include a unique combination of skills not yet fully defined. This presents challenges when recruiting the correct people for training. Skills are thought to include visuospatial perception and psychomotor skills, but little is known about the relationship between these aptitudes and scanning ability. This feasibility study explored such relationships, to identify evaluation techniques which may improve selection and recruitment. Methods A sample of 30 experienced ultrasound practitioners and 30 trainees at commencement and on completion of training were administered eight tests. Results No significant relationships between experienced practitioners’ or trainees’ visuospatial abilities or psychomotor abilities and scanning abilities were found. Results demonstrated that two of the visuospatial perception tests were not influenced by training and therefore, may be measuring the innate skills of ultrasound practitioners. As ultrasound practitioners had not performed any of the tests previously, ranges of scores for each of the eight tests were established for this group. This included measures for psychomotor skills which added to the current body of knowledge for sonography. Conclusions Although no significant correlations were found between participants’ visuospatial perception or psychomotor abilities and scanning ability, performance on the Obstetric Structured Assessment Test (combining all the skills required) pre-training gave the best indication of post-training scanning performance. The Obstetric Structured Assessment Test may prove a useful tool for initial assessment of potential trainees but abilities will require further investigation. PMID:27847536

  19. Doppler ultrasound scan during normal gestation: umbilical circulation; Ecografia Doppler en la gestacion normal: circulacion umbilical

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, T.; Sabate, J.; Martinez-Benavides, M. M.; Sanchez-Ramos, J. [Hospital Virgen Macarena. Sevilla (Spain)

    2002-07-01

    To determine normal umbilical circulation patterns by means of Doppler ultrasound scan in a healthy gestating population without risk factors and with normal perinatal results, and to evaluate any occurring modifications relative to gestational age by obtaining records kept during pregnancy. One hundred and sixteen pregnant women carrying a single fetus have been studied. These women had no risk factors, with both clinical and analytical controls, as well as ultrasound scans, all being normal. There were performed a total of 193 Doppler ultrasound scans between weeks 15 and 41 of gestation, with blood-flow analysis in the arteries and vein of the umbilical cord. The obtained information was correlated with parameters that evaluate fetal well-being (fetal monitoring and/or oxytocin test) and perinatal result (delivery type, birth weight, Apgar score). Statistical analysis was performed with the programs SPSS 6.0.1 for Windows and EPIINFO 6.0.4. With pulsed Doppler, the umbilical artery in all cases demonstrated a biphasic morphology with systolic and diastolic components and without retrograde blood flow. As the gestation period increased, there was observed a progressive decrease in resistance along with an increase in blood-flow velocity during the diastolic phase. The Doppler ultrasound scan is a non-invasive method that permits the hemodynamic study of umbilical blood circulation. A knowledge of normal blood-flow signal morphology, as well as of the normal values for Doppler indices in relation to gestational age would permit us to utilize this method in high-risk pregnancies. (Author) 30 refs.

  20. Laser Ultrasound Spectroscopy Scanning for 3D Printed Parts

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, Guendalyn Kendra [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-04

    One of the challenges of additive manufacturing is quality control due to the possibility of unseen flaws in the final product. The current methods of inspection are lacking in detail, too slow for practical use, or unable to validate internal structure. This report examines the use of laser ultrasound spectroscopy in layer by layer scans of 3D printed parts as they are created. The result is fast and detailed quality control. An additional advantage of this method is the ability to cancel a print as soon as a defect is detected, therefore saving materials and time. This technique, though simple in concept, has been a challenge to implement. I discuss tweaking the 3D printer configuration, and finding the optimal settings for laser scanning small parts made of ABS plastic, as well as the limits of how small of a detail the laser can detect. These settings include the frequency of the ultrasonic transducer, the speed of the laser, and the distance from the laser to the part.

  1. Performance of chest ultrasound in pediatric pneumonia

    International Nuclear Information System (INIS)

    Claes, Anne-Sophie; Clapuyt, Philippe; Menten, Renaud; Michoux, Nicolas; Dumitriu, Dana

    2017-01-01

    Highlights: • Prospective comparison between chest X-ray and thoracic ultrasound for the detection of pneumonia in children. • Good correlation between X-ray and ultrasound for the detection and localization of pneumonia. • Thoracic ultrasound has an excellent negative predictive value (99%) for pediatric pneumonia. • Ultrasound may be used as a non-ionizing alternative to X-ray to exclude pneumonia in children. - Abstract: Objective: The objective of this study was to evaluate the performance of ultrasound in detecting lung consolidation in children suspected of pneumonia, in comparison to the current gold standard, chest X-rays. Materials and methods: From September 2013 to June 2014, a monocentric prospective study was performed on all children between 0 and 16 years-old, referred for chest X-ray for suspected pneumonia. Each child was examined by chest ultrasound by an examiner blinded to the chest X-ray. The presence or absence of areas of consolidation, their number and location were noted for each technique. The size of the consolidations identified only on ultrasound was compared with that of consolidations visible on both techniques. Results: 143 children (mean age 3 years; limits between 8 days and 14 years) were included. Ultrasound detected at least one area of consolidation in 44 out of 45 patients with positive X-rays. Of the 59 areas of consolidation on X-ray, ultrasound identified 54. In the 8 patients with negative X-ray, ultrasound revealed 17 areas of consolidation. The mean size of consolidations visible only on ultrasound was 9.4 mm; for consolidations visible on both techniques the mean size was 26 mm (p < 0.0001). The sensitivity and specificity of ultrasound were calculated at 98% and 92%. PPV and NPV were 85% and 99%, respectively. Conclusion: Chest ultrasound is a fast, non-ionizing and feasible technique. With its high negative predictive value, it can replace X-rays in order to exclude lung consolidation in children, thus

  2. Performance of chest ultrasound in pediatric pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Claes, Anne-Sophie, E-mail: anso.claes@gmail.com [Departement of Radiology, Pediatric and Thoracic Radiology Unit, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Clapuyt, Philippe, E-mail: philippe.clapuyt@uclouvain.be [Departement of Radiology, Pediatric Radiology Unit, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Menten, Renaud, E-mail: renaud.menten@uclouvain.be [Departement of Radiology, Pediatric Radiology Unit, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Michoux, Nicolas, E-mail: nicolas.michoux@uclouvain.be [Departement of Radiology, Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Dumitriu, Dana, E-mail: dana.dumitriu@uclouvain.be [Departement of Radiology, Pediatric Radiology Unit, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium)

    2017-03-15

    Highlights: • Prospective comparison between chest X-ray and thoracic ultrasound for the detection of pneumonia in children. • Good correlation between X-ray and ultrasound for the detection and localization of pneumonia. • Thoracic ultrasound has an excellent negative predictive value (99%) for pediatric pneumonia. • Ultrasound may be used as a non-ionizing alternative to X-ray to exclude pneumonia in children. - Abstract: Objective: The objective of this study was to evaluate the performance of ultrasound in detecting lung consolidation in children suspected of pneumonia, in comparison to the current gold standard, chest X-rays. Materials and methods: From September 2013 to June 2014, a monocentric prospective study was performed on all children between 0 and 16 years-old, referred for chest X-ray for suspected pneumonia. Each child was examined by chest ultrasound by an examiner blinded to the chest X-ray. The presence or absence of areas of consolidation, their number and location were noted for each technique. The size of the consolidations identified only on ultrasound was compared with that of consolidations visible on both techniques. Results: 143 children (mean age 3 years; limits between 8 days and 14 years) were included. Ultrasound detected at least one area of consolidation in 44 out of 45 patients with positive X-rays. Of the 59 areas of consolidation on X-ray, ultrasound identified 54. In the 8 patients with negative X-ray, ultrasound revealed 17 areas of consolidation. The mean size of consolidations visible only on ultrasound was 9.4 mm; for consolidations visible on both techniques the mean size was 26 mm (p < 0.0001). The sensitivity and specificity of ultrasound were calculated at 98% and 92%. PPV and NPV were 85% and 99%, respectively. Conclusion: Chest ultrasound is a fast, non-ionizing and feasible technique. With its high negative predictive value, it can replace X-rays in order to exclude lung consolidation in children, thus

  3. Approach to treatment for obstructive jaundice of PTCD guided by combining ultrasound with X-ray scan

    International Nuclear Information System (INIS)

    Tang Huanliang; Cao Haoqian; Fei Jianguo

    2008-01-01

    Objective: To investigate the technical and clinical value of PTCD in patients with obstructive jaundice by the guiding of ultrasound combined with X-ray scan. Methods PTCD was performed in 58 patients with obstructive jaundice, with 47 patients malignant diseases and 11 patients benign diseases, guided by combining ultrasound and X-ray scan. 51 patients were punctured to right bile ducts and 7 cases were left bile ducts. Cholangiography was routinely used. Results: Technical success was obtained in all patients. No bleeding and biliary peritonitis were found after procedures. The bilirubin was reduced by 75.4ummol/L one week after operation. Conclusion: The technique of PTCD guided by combining ultrasound with X-ray scan was safe, simple, cost saving and less complications for obstructive jaundice. (authors)

  4. Value of Abdominal Radiography, Colonic Transit Time, and Rectal Ultrasound Scanning in the Diagnosis of Idiopathic Constipation in Children : A Systematic Review

    NARCIS (Netherlands)

    Berger, Marjolein Y.; Tabbers, Merit M.; Kurver, Miranda J.; Boluyt, Nicole; Benninga, Marc A.

    Objective To perform a systematic review evaluating the value of abdominal radiography, colonic transit time (CTT), and rectal ultrasound scanning in the diagnosis of idiopathic constipation in children. Study design Eligible studies were those assessing diagnostic accuracy of abdominal radiography,

  5. Ultrasound

    Science.gov (United States)

    ... reflect off body structures. A computer receives the waves and uses them to create a picture. Unlike with an x-ray or CT scan, this test does not use ionizing radiation. The test is done in the ultrasound ...

  6. Discrimination between Newly Formed and Aged Thrombi Using Empirical Mode Decomposition of Ultrasound B-Scan Image

    Directory of Open Access Journals (Sweden)

    Jui Fang

    2015-01-01

    Full Text Available Ultrasound imaging is a first-line diagnostic method for screening the thrombus. During thrombus aging, the proportion of red blood cells (RBCs in the thrombus decreases and therefore the signal intensity of B-scan can be used to detect the thrombus age. To avoid the effect of system gain on the measurements, this study proposed using the empirical mode decomposition (EMD of ultrasound image as a strategy to classify newly formed and aged thrombi. Porcine blood samples were used for the in vitro induction of fresh and aged thrombi (at hematocrits of 40%. Each thrombus was imaged using an ultrasound scanner at different gains (15, 20, and 30 dB. Then, EMD of ultrasound signals was performed to obtain the first and second intrinsic mode functions (IMFs, which were further used to calculate the IMF-based echogenicity ratio (IER. The results showed that the performance of using signal amplitude of B-scan to reflect the thrombus age depends on gain. However, the IER is less affected by the gain in discriminating between fresh and aged thrombi. In the future, ultrasound B-scan combined with the EMD may be used to identify the thrombus age for the establishment of thrombolytic treatment planning.

  7. Ultrasound scans and dual energy CT identify tendons as preferred anatomical location of MSU crystal depositions in gouty joints.

    Science.gov (United States)

    Yuan, Yuan; Liu, Chang; Xiang, Xi; Yuan, Tong-Ling; Qiu, Li; Liu, Yi; Luo, Yu-Bin; Zhao, Y; Herrmann, Martin

    2018-05-01

    The present study was performed to localize the articular deposition of monosodium urate (MSU) crystal in joints. We compare the detection efficiencies of dual-energy CT (DECT) and ultrasound scans. Analyses by DECT and ultrasound were performed with 184 bilateral joints of the lower limbs of 54 consecutive gout patients. All joints were categorized into (1) knee, (2) ankle, (3) MTP1, and (4) MTP2, and sorted into those with and those without detectable MSU deposition. The comparison of the positive rate between DECT and ultrasound and the agreement was performed using the McNemar test and the Cohen's κ coefficient, respectively. Next, we listed the MSU crystal deposition as assessed by ultrasound between the DECT-positive and -negative joints according to their interior structure. We included tendons, synovia, cartilage, subcutaneous tissue, etc. RESULTS: Among all joints, the percentages with MSU crystal deposition detected by DECT (99/184, 53.8%) and ultrasound (106/184, 57.6%) were comparable (P = 0.530 > 0.05). For MTP1 (21/34, 61.8%; 12/34, 35.3%; P efficient, respectively. The data concordance in 46 of 50 joints (92.00%; κ = 0.769, P location of MSU crystal deposition. The tendons are the most frequent anatomical location of MSU crystal depositions. The concordance rate of knee joints and MTP2-5 joints shows good agreement between DECT and ultrasound depending on the location.

  8. Mechanical scanning in intravascular ultrasound imaging: Artifacts and driving mechanisms

    NARCIS (Netherlands)

    H. ten Hoff (H.); E.J. Gussenhoven (Elma); C.M. Korbijn (Carin); F. Mastik (Frits); C.T. Lancée (Charles); N. Bom (Klaas)

    1995-01-01

    textabstractObjective: Currently, intravascular ultrasound (US) imaging catheters are developed and produced to provide a complementary diagnostic method in the treatment of blood vessel obstructive disease. Typical catheter dimensions are a diameter of 1–2.5 mm and a length of 1–1.5 m. A real-time

  9. Endoscopic ultrasound duplex scanning for measurement of portal venous flow. Validation against transit time ultrasound flowmetry in pigs

    DEFF Research Database (Denmark)

    Hansen, E F; Strandberg, C; Bendtsen, F

    1999-01-01

    with that of transit time ultrasound (TTU) in healthy pigs. The ability of EUS to detect changes in the portal venous flow after pharmacologic intervention was also investigated. METHODS: Six anaesthetized pigs were studied. Portal venous flow was measured simultaneously by EUS duplex scanning, using a Pentax FG-32UA...... echoendoscope connected to a Hitachi EUB 515-A ultrasound scanner, and by TTU with a Cardiomed CM 4000 flowmeter probe placed on the portal vein. Terlipressin, 1 mg, and placebo were administered in a blind, randomized, crossover design. Measurements were taken at base line and 30 min after each drug...

  10. Focal hepatic steatosis: ultrasound and CT scan features may mimick carcinoma of the liver

    International Nuclear Information System (INIS)

    Monnin, J.L.; Blanc, F.; Guiry, P.; Bruel, J.M.; Monnin, E.; Ciurana, A.J.

    1988-01-01

    Ultrasound and CT scan features of focal hepatic steatosis (FHS) may closely resemble those of primary or secondary malignant hepatic tumors. Three cases of FHS in chronic alcoholics are reported. In two cases, the area of steatosis was hyperechogenic upon ultrasonography. In all three patients, CT scan demonstrated a hypodense image, with poor enhancement following opacification and no mass effect. Diagnosis of FHS was ascertained upon hepatic biopsy under CT scan guidance in all three patients [fr

  11. A postmortem correlation of computer tomography and ultrasound scans of periventricular hemorrhage in preterm infants

    International Nuclear Information System (INIS)

    Fukuda, Seiichi; Hashimoto, Takeo; Yamashita, Yushiro; Nishimi, Toshihiro; Utsunomiya, Hidetsuna; Nakamura, Yasuhiro; Okudera, Toshio

    1988-01-01

    From January 1984 through September 1987, ultrasound scanning (US), computed tomography (CT), and autopy have been performed in 80 consecutive premature infants. Intracranial lesions consisted of intraventricular hemorrhage (IVH, n = 61), subarachnoid hemorrhage (SAH, n = 63), cerebellar hemorrhage (n = 5), hydrocephalus (n = 8), periventricular leukoencephalomalacia (n = 20), and anoxic encephalopathy (n = 40). Using autopsy findings as the standard, both US and CT had an accuracy of 80 % or more in detecting subependymal hemorrhage (SEH), IVH, dilated ventricle, and parenchymal hemorrhage ; however, both imaging modalities showed a high false negative for SAH (77 % for US vs 55 % for CT). Accuracy of US and CT was 82 % vs 72 % for SEH, and 72 % vs 85 % for IVH. High false positive and false negative rates, in spite of 80 % or more accuracy of imaging modalities, warrant further studies to obtain higher accuracy in the diagnosis of intracranial lesions. (Namekawa, K.)

  12. Postmortem correlation of computer tomography and ultrasound scans of periventricular hemorrhage in preterm infants

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Seiichi; Hashimoto, Takeo; Yamashita, Yushiro; Nishimi, Toshihiro; Utsunomiya, Hidetsuna; Nakamura, Yasuhiro; Okudera, Toshio

    1988-08-01

    From January 1984 through September 1987, ultrasound scanning (US), computed tomography (CT), and autopy have been performed in 80 consecutive premature infants. Intracranial lesions consisted of intraventricular hemorrhage (IVH, n = 61), subarachnoid hemorrhage (SAH, n = 63), cerebellar hemorrhage (n = 5), hydrocephalus (n = 8), periventricular leukoencephalomalacia (n = 20), and anoxic encephalopathy (n = 40). Using autopsy findings as the standard, both US and CT had an accuracy of 80 % or more in detecting subependymal hemorrhage (SEH), IVH, dilated ventricle, and parenchymal hemorrhage ; however, both imaging modalities showed a high false negative for SAH (77 % for US vs 55 % for CT). Accuracy of US and CT was 82 % vs 72 % for SEH, and 72 % vs 85 % for IVH. High false positive and false negative rates, in spite of 80 % or more accuracy of imaging modalities, warrant further studies to obtain higher accuracy in the diagnosis of intracranial lesions. (Namekawa, K.).

  13. Ultrasound of the acute abdomen performed by surgeons in training

    DEFF Research Database (Denmark)

    Eiberg, J.P.; Grantcharov, T.P.; Eriksen, J.R.

    2008-01-01

    , specificity and kappa-agreement of the surgeon performed ultrasound examination was 1.00 (0.77-1.00), 0.96 (0.79-0.99), 0.94 (0.3-1.00) and 0.40 (0.12-0.77), 0.97 (0.83-0.99), 0.44 (0.00-0.96); respectively. Visualization of the common bile duct was poor having 73% non-diagnostic surgeon-performed ultrasound...... perform valid abdominal ultrasound examinations of patients referred with acute abdominal pain. METHODS: Patients referred with acute abdominal pain had an ultrasound examination by a surgeon in training as well as by an experienced consultant radiologist whose results served as the gold standard. All...... participating surgeons were without any pre-existing ultrasound experience and received one hour of introduction to abdominal ultrasound. RESULTS: Thirty patients underwent 40 surgeon performed and 30 radiologist performed ultrasound examinations. Regarding gallstone and cholecholecystitis the sensitivity...

  14. Simultaneous delivery of electron beam therapy and ultrasound hyperthermia using scanning reflectors: a feasibility study

    International Nuclear Information System (INIS)

    Moros, Eduardo G.; Straube, William L.; Klein, Eric E.; Yousaf, Muhammed; Myerson, Robert J.

    1995-01-01

    Purpose: The feasibility of simultaneously delivering external electron beam radiation and superficial hyperthermia using a scanning ultrasound reflector-array system (SURAS) was experimentally investigated and demonstrated. Methods and Materials: A new system uses a scanning reflector to distribute the acoustic energy from a planar ultrasound array over the surface of the target volume. External photon/electron beams can be concurrently delivered with hyperthermia by irradiating through the scanning reflectors. That is, this system enables the acoustic waves and the radiation beams to enter the target volume from the same direction. Reflectors were constructed of air-equivalent materials for maximum acoustic reflection and minimum radiation attenuation. Acoustically, the air reflectors were compared to brass reflectors (assumed ideal) for reflectivity and specular quality using several single transducers ranging in frequency from 0.68 to 4.8 MHz. The relative reflectivity was determined from acoustic power measurements using a force-balance technique. The specular quality was assessed by comparing the acoustic pressure fields reflected by air reflectors with those reflected by brass reflectors. Also, acoustic pressure fields generated by a SURAS prototype for two different arrays (2.24 and 4.5 MHz) were measured to investigate field distribution variations as a function of the distance separating the array and the scanning reflector. All pressure fields were measured with a hydrophone in a degassed water tank. Finally, to determine the effect of the air reflectors on electron dose distributions, these were measured using film in a water-equivalent solid phantom after passage of a 20 MeV electron beam through the SURAS. These measurements were performed with the reflector scanning continuously across the electron beam and at rest within the electron beam. Results: The measurements performed using single ultrasound transducers showed that the air reflectors had

  15. Human performance in radiological survey scanning

    International Nuclear Information System (INIS)

    Brown, W.S.; Abelquist, E.W.

    1998-03-01

    The probability of detecting residual contamination in the field using portable radiological survey instruments depends not only on the sensitivity of the instrumentation used in scanning, but also on the surveyor's performance. This report provides a basis for taking human performance into account in determining the minimum level of activity detectable by scanning. A theoretical framework was developed (based on signal detection theory) which allows influences on surveyors to be anticipated and understood, and supports a quantitative assessment of performance. The performance of surveyors under controlled yet realistic field conditions was examined to gain insight into the task and to develop means of quantifying performance. Then, their performance was assessed under laboratory conditions to quantify more precisely their ability to make the required discriminations. The information was used to characterize surveyors' performance in the scanning task and to provide a basis for predicting levels of radioactivity that are likely to be detectable under various conditions by surveyors using portable survey instruments

  16. Human performance in radiological survey scanning

    Energy Technology Data Exchange (ETDEWEB)

    Brown, W.S. [Brookhaven National Lab., Upton, NY (United States); Abelquist, E.W. [Oak Ridge Inst. for Science and Education, TN (United States)

    1998-03-01

    The probability of detecting residual contamination in the field using portable radiological survey instruments depends not only on the sensitivity of the instrumentation used in scanning, but also on the surveyor`s performance. This report provides a basis for taking human performance into account in determining the minimum level of activity detectable by scanning. A theoretical framework was developed (based on signal detection theory) which allows influences on surveyors to be anticipated and understood, and supports a quantitative assessment of performance. The performance of surveyors under controlled yet realistic field conditions was examined to gain insight into the task and to develop means of quantifying performance. Then, their performance was assessed under laboratory conditions to quantify more precisely their ability to make the required discriminations. The information was used to characterize surveyors` performance in the scanning task and to provide a basis for predicting levels of radioactivity that are likely to be detectable under various conditions by surveyors using portable survey instruments.

  17. Estimation of pulses in ultrasound B-scan images

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    1991-01-01

    It is shown, based on an expression for the received pressure field in pulsed medical ultrasound systems, that a common one-dimensional pulse can be estimated from individual A-lines. An autoregressive moving average (ARMA) model is suggested for the pulse, and an estimator based on the prediction...... error method is derived. The estimator is used on a segment of an A-line, assuming that the pulse does not change significantly inside the segment. Several examples of the use of the estimator on synthetic data measured from a tissue phantom and in vitro data measured from a calf's liver are given....... They show that a pulse can be estimated even at moderate signal-to-noise ratios...

  18. Performance of Bedside Lung Ultrasound by a Pediatric Resident

    DEFF Research Database (Denmark)

    Zhan, Chen; Grundtvig, Natalia; Klug, Bent Helmuth

    2017-01-01

    OBJECTIVES: Recent studies suggest that lung ultrasound is a good, radiation-free alternative to chest radiography in children with pneumonia. We investigated how bedside lung ultrasound performed by a pediatric resident compared with chest radiography in children with suspected pneumonia. METHODS......: This was a prospective study comparing bedside lung ultrasound to chest radiography as the reference standard. Children aged 0 to 15 years with suspected pneumonia at a pediatric emergency department were included and underwent chest radiography and lung ultrasound. A pediatric resident with minimal practical ultrasound...

  19. Paediatric renal length measurements from ultrasound and DMSA scans: does clinical practice reflect theoretical normal values?

    International Nuclear Information System (INIS)

    Que, L.; Rutland, M.D.; Hassan, I.M.

    1999-01-01

    Full text: Renal length measurement is a routine part of ultrasound examination in children and those results are plotted on a normogram style graph, so that each child's results are compared to a normal range (mean ± 2 S.D.). Renal length measurements from the posterior oblique views of dimercaptosuccinic acid (DMSA) scans in our department have not always correlated well with the ultrasound measurements on the same patients. Renal lengths from the DMSA scans of 120 patients with apparently normal kidneys were recorded and used to generate a normogram of renal length at different ages (0.5-7 years). This DMSA normogram was compared to the ultrasound (US) normogram used in the Paediatric Radiology Department, and it showed slight differences in renal lengths (3-8 mm), but that the US normogram had smaller coefficients of variation (US = 6.6%, NM 8.3%), implying a 'tighter' normal range. 39 of these patients had DMSA and ultrasound measurements of renal length within 3 months, and these were studied first by calculating the mean and CV values for different age groups, and then by plotting individual renal lengths on the appropriate normograms. The measured data produced much greater variability in the ultrasound measurements than the DTPA measurements, and the individual points produced 4/78 (5.1%) abnormal results for DMSA, but 21/78 (26.9%) abnormal results for ultrasound. Thus, in routine clinical use, using patients with apparently normal kidneys, ultrasound was unable to match the 'normal range' set by their current normogram, but the nuclear medicine showed 5.1% of values outside the normal (DMSA) range, which was completely appropriate for a range of ± 2 standard deviations

  20. Emergency medicine physicians performed ultrasound for pediatric intussusceptions

    Directory of Open Access Journals (Sweden)

    Yi-Jung Chang

    2013-08-01

    Full Text Available Background: Intussusception is the common acute abdomen in children with difficult clinical diagnosis. The routine ultrasound has recently been proposed as the initial diagnostic modality with high accuracy, but is not available for 24 h by gastroenterologists. We aimed to evaluate the validation of bedside ultrasound for intussusceptions performed by pediatric emergency physicians with ultrasound training during the night or holiday. Methods: A retrospective study was conducted in children with suspected intussusceptions when routine ultrasounds by gastroenterologists were not available over the period from July 2004 to July 2008. Patients were divided into two groups: those diagnosed by emergency physicians with ultrasound training and without training. The clinical characteristics and course for all patients were reviewed and compared for seeking the difference. Results: A total of 186 children were included. One hundred and thirteen (61% children were diagnosed by pediatric emergency physician with ultrasound training. The clinical symptoms were not statistically different between the two groups. The diagnostic sensitivity of the ultrasound training group was significantly higher (90% vs. 79%, p = 0.034. Children of the training group also had significantly shorter hospital stay duration at emergency departments before reduction (2.41 ± 2.01 vs. 4.58 ± 4.80 h, p = 0.002. Conclusion: Bedside ultrasound performed by pediatric emergency physicians with ultrasound training is a sensitive test for detecting intussusceptions. Knowledge and use of bedside ultrasound can aid the emergency physician in the diagnosis of pediatric intussusceptions with less delay in treatment.

  1. The utility of neck ultrasound and sestamibi scans in patients with secondary and tertiary hyperparathyroidism.

    Science.gov (United States)

    Alkhalili, Eyas; Tasci, Yunus; Aksoy, Erol; Aliyev, Shamil; Soundararajan, Saranya; Taskin, Eren; Siperstein, Allan; Berber, Eren

    2015-03-01

    Secondary hyperparathyroidism (SHPT) and tertiary hyperparathyroidism (THPT) are disease entities in patients with chronic kidney disease that are caused by parathyroid hyperplasia. The role of preoperative localization studies in patients undergoing parathyroidectomy for these conditions remains poorly defined. To evaluate the utility of surgeon-performed neck ultrasound (US) as well as sestamibi scans in the localization of parathyroid glands in patients with SHPT/THPT. A retrospective analysis of patients with SHPT/THPT who underwent parathyroidectomy at a single institution. Results of preoperative localization studies were compared to intraoperative findings. One hundred and three patients underwent parathyroidectomy for SHPT/THPT. All patients underwent surgeon-performed neck US, while 92 (89%) underwent sestamibi scans. US failed to localize any of the parathyroids in 4 patients (3.8%), while sestamibi was negative in 11 (12%). Forty-seven ectopic glands were identified in 38 patients in whom sestamibi was performed. In five patients (13%), ectopic glands were identified by both modalities, by US only in 6 (16%), by sestamibi only in 8 (21%), and by neither study in 19 patients (50%). US showed new thyroid nodules in 19 patients (18.4 %), leading to lobectomy or thyroidectomy at the time of parathyroidectomy in 16 patients (15.5%). Pathology showed malignancy in 7 patients (6.8%). US and MIBI offer little benefit in localizing ectopic glands and rarely change the conduct of a standard four-gland exploration. Although there was a benefit of US in the assessment of thyroid nodules, in only 8.7% of patients was sestamibi of benefit in identifying ectopic glands.

  2. Improved detection and biopsy of solid liver lesions using pulse-inversion ultrasound scanning and contrast agent infusion

    DEFF Research Database (Denmark)

    Skjoldbye, B.; Pedersen, Morten Høgholm; Struckmann, J.

    2002-01-01

    The purpose of this study was to assess the ability of pulse-inversion ultrasound (US) scanning (PIUS), combined with an IV contrast agent, to detect malignant liver lesions and its impact on patient management (resectability). Additionally, to determine the feasibility of US-guided biopsy of new...... PIUS-findings at the same session. A total of 30 patients with known or clinically suspected cancer underwent conventional B-mode scanning and PIUS with IV-administered contrast agent. The number of liver metastases in the right and the left liver lobe, respectively, was recorded. All patients...... findings were performed in 17 of 18 patients. All biopsies of additional findings confirmed malignancy. PIUS with an IV contrast agent increased the ability to detect liver metastases compared to conventional US scanning. The technique had a high impact on patient management. The results showed that PIUS...

  3. Consensus-based identification of factors related to false-positives in ultrasound scanning of synovitis and tenosynovitis.

    Science.gov (United States)

    Ikeda, Kei; Narita, Akihiro; Ogasawara, Michihiro; Ohno, Shigeru; Kawahito, Yutaka; Kawakami, Atsushi; Ito, Hiromu; Matsushita, Isao; Suzuki, Takeshi; Misaki, Kenta; Ogura, Takehisa; Kamishima, Tamotsu; Seto, Yohei; Nakahara, Ryuichi; Kaneko, Atsushi; Nakamura, Takayuki; Henmi, Mihoko; Fukae, Jun; Nishida, Keiichiro; Sumida, Takayuki; Koike, Takao

    2016-01-01

    We aimed to identify causes of false-positives in ultrasound scanning of synovial/tenosynovial/bursal inflammation and provide corresponding imaging examples. We first performed systematic literature review to identify previously reported causes of false-positives. We next determined causes of false-positives and corresponding example images for educational material through Delphi exercises and discussion by 15 experts who were an instructor and/or a lecturer in the 2013 advanced course for musculoskeletal ultrasound organized by Japan College of Rheumatology Committee for the Standardization of Musculoskeletal Ultrasonography. Systematic literature review identified 11 articles relevant to sonographic false-positives of synovial/tenosynovial inflammation. Based on these studies, 21 candidate causes of false-positives were identified in the consensus meeting. Of these items, 11 achieved a predefined consensus (≥ 80%) in Delphi exercise and were classified as follows: (I) Gray-scale assessment [(A) non-specific synovial findings and (B) normal anatomical structures which can mimic synovial lesions due to either their low echogenicity or anisotropy]; (II) Doppler assessment [(A) Intra-articular normal vessels and (B) reverberation)]. Twenty-four corresponding examples with 49 still and 23 video images also achieved consensus. Our study provides a set of representative images that can help sonographers to understand false-positives in ultrasound scanning of synovitis and tenosynovitis.

  4. Multiplatform Mobile Laser Scanning: Usability and Performance

    Directory of Open Access Journals (Sweden)

    Yuwei Chen

    2012-08-01

    Full Text Available Mobile laser scanning is an emerging technology capable of capturing three-dimensional data from surrounding objects. With state-of-the-art sensors, the achieved point clouds capture object details with good accuracy and precision. Many of the applications involve civil engineering in urban areas, as well as traffic and other urban planning, all of which serve to make 3D city modeling probably the fastest growing market segment in this field. This article outlines multiplatform mobile laser scanning solutions such as vehicle- and trolley-operated urban area data acquisition, and boat-mounted equipment for fluvial environments. Moreover, we introduce a novel backpack version of mobile laser scanning equipment for surveying applications in the field of natural sciences where the requirements include precision and mobility in variable terrain conditions. In addition to presenting a technical description of the systems, we discuss the performance of the solutions in the light of various applications in the fields of urban mapping and modeling, fluvial geomorphology, snow-cover characterization, precision agriculture, and in monitoring the effects of climate change on permafrost landforms. The data performance of the mobile laser scanning approach is described by the results of an evaluation of the ROAMER on a permanent MLS test field. Furthermore, an in situ accuracy assessment using a field of spherical 3D targets for the newly-introduced Akhka backpack system is conducted and reported on.

  5. Ultrasound line-by-line scanning method of spatial-temporal active cavitation mapping for high-intensity focused ultrasound.

    Science.gov (United States)

    Ding, Ting; Zhang, Siyuan; Fu, Quanyou; Xu, Zhian; Wan, Mingxi

    2014-01-01

    This paper presented an ultrasound line-by-line scanning method of spatial-temporal active cavitation mapping applicable in a liquid or liquid filled tissue cavities exposed by high-intensity focused ultrasound (HIFU). Scattered signals from cavitation bubbles were obtained in a scan line immediately after one HIFU exposure, and then there was a waiting time of 2 s long enough to make the liquid back to the original state. As this pattern extended, an image was built up by sequentially measuring a series of such lines. The acquisition of the beamformed radiofrequency (RF) signals for a scan line was synchronized with HIFU exposure. The duration of HIFU exposure, as well as the delay of the interrogating pulse relative to the moment while HIFU was turned off, could vary from microseconds to seconds. The feasibility of this method was demonstrated in tap-water and a tap-water filled cavity in the tissue-mimicking gelatin-agar phantom as capable of observing temporal evolutions of cavitation bubble cloud with temporal resolution of several microseconds, lateral and axial resolution of 0.50 mm and 0.29 mm respectively. The dissolution process of cavitation bubble cloud and spatial distribution affected by cavitation previously generated were also investigated. Although the application is limited by the requirement for a gassy fluid (e.g. tap water, etc.) that allows replenishment of nuclei between HIFU exposures, the technique may be a useful tool in spatial-temporal cavitation mapping for HIFU with high precision and resolution, providing a reference for clinical therapy. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Quality assurance of lower limb venous duplex scans performed by vascular surgeons.

    Science.gov (United States)

    Kordowicz, A; Ferguson, G; Salaman, R; Onwudike, M

    2015-02-01

    Duplex scanning is the gold standard for investigating venous reflux; increasingly surgeons perform these scans themselves. There has been no data published analysing the accuracy of Duplex scans performed by vascular surgeons. We aimed to evaluate an objective method of comparing the results of lower limb Duplex scans performed by one consultant vascular surgeon with those performed by a vascular technologist. We assessed 100 legs with symptomatic varicose veins. Each patient underwent two lower limb venous Duplex scans; one performed by a consultant vascular surgeon and one by a vascular technologist. Scan results were randomised and sent to two consultant vascular surgeons blinded to the identity and experience of the sonographer. They were asked to recommend treatment. A k score was calculated in each case to assess the level of agreement between the scans performed by the consultant and the technologist. Eighty-one patients were studied (53 females). The kappa score for assessor 1 was 0.60 (95%CI:0.44-0.75) and for assessor 2 was 0.62 (95%CI:0.48-0.75). k scores >0.60 represent a substantial strength of agreement. Duplex scans performed by this surgeon were comparable to those performed by a vascular technologist. It is possible to quality-assure duplex performed by vascular surgeons without directly observing the scanning process or reviewing digitally recorded images. We propose standardisation of training, assessment and quality assurance for vascular surgeons wishing to perform ultrasound scans.

  7. Non-invasive transcranial ultrasound therapy based on a 3D CT scan: protocol validation and in vitro results

    International Nuclear Information System (INIS)

    Marquet, F; Pernot, M; Aubry, J-F; Montaldo, G; Tanter, M; Fink, M; Marsac, L

    2009-01-01

    A non-invasive protocol for transcranial brain tissue ablation with ultrasound is studied and validated in vitro. The skull induces strong aberrations both in phase and in amplitude, resulting in a severe degradation of the beam shape. Adaptive corrections of the distortions induced by the skull bone are performed using a previous 3D computational tomography scan acquisition (CT) of the skull bone structure. These CT scan data are used as entry parameters in a FDTD (finite differences time domain) simulation of the full wave propagation equation. A numerical computation is used to deduce the impulse response relating the targeted location and the ultrasound therapeutic array, thus providing a virtual time-reversal mirror. This impulse response is then time-reversed and transmitted experimentally by a therapeutic array positioned exactly in the same referential frame as the one used during CT scan acquisitions. In vitro experiments are conducted on monkey and human skull specimens using an array of 300 transmit elements working at a central frequency of 1 MHz. These experiments show a precise refocusing of the ultrasonic beam at the targeted location with a positioning error lower than 0.7 mm. The complete validation of this transcranial adaptive focusing procedure paves the way to in vivo animal and human transcranial HIFU investigations.

  8. Non-invasive transcranial ultrasound therapy based on a 3D CT scan: protocol validation and in vitro results

    Energy Technology Data Exchange (ETDEWEB)

    Marquet, F; Pernot, M; Aubry, J-F; Montaldo, G; Tanter, M; Fink, M [Laboratoire Ondes et Acoustique, ESPCI, Universite Paris VII, UMR CNRS 7587, 10 rue Vauquelin, 75005 Paris (France); Marsac, L [Supersonic Imagine, Les Jardins de la Duranne, 510 rue Rene Descartes, 13857 Aix-en-Provence (France)], E-mail: fabrice.marquet@espci.org

    2009-05-07

    A non-invasive protocol for transcranial brain tissue ablation with ultrasound is studied and validated in vitro. The skull induces strong aberrations both in phase and in amplitude, resulting in a severe degradation of the beam shape. Adaptive corrections of the distortions induced by the skull bone are performed using a previous 3D computational tomography scan acquisition (CT) of the skull bone structure. These CT scan data are used as entry parameters in a FDTD (finite differences time domain) simulation of the full wave propagation equation. A numerical computation is used to deduce the impulse response relating the targeted location and the ultrasound therapeutic array, thus providing a virtual time-reversal mirror. This impulse response is then time-reversed and transmitted experimentally by a therapeutic array positioned exactly in the same referential frame as the one used during CT scan acquisitions. In vitro experiments are conducted on monkey and human skull specimens using an array of 300 transmit elements working at a central frequency of 1 MHz. These experiments show a precise refocusing of the ultrasonic beam at the targeted location with a positioning error lower than 0.7 mm. The complete validation of this transcranial adaptive focusing procedure paves the way to in vivo animal and human transcranial HIFU investigations.

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  11. Comparative study of lesions created by high-intensity focused ultrasound using sequential discrete and continuous scanning strategies.

    Science.gov (United States)

    Fan, Tingbo; Liu, Zhenbo; Zhang, Dong; Tang, Mengxing

    2013-03-01

    Lesion formation and temperature distribution induced by high-intensity focused ultrasound (HIFU) were investigated both numerically and experimentally via two energy-delivering strategies, i.e., sequential discrete and continuous scanning modes. Simulations were presented based on the combination of Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation and bioheat equation. Measurements were performed on tissue-mimicking phantoms sonicated by a 1.12-MHz single-element focused transducer working at an acoustic power of 75 W. Both the simulated and experimental results show that, in the sequential discrete mode, obvious saw-tooth-like contours could be observed for the peak temperature distribution and the lesion boundaries, with the increasing interval space between two adjacent exposure points. In the continuous scanning mode, more uniform peak temperature distributions and lesion boundaries would be produced, and the peak temperature values would decrease significantly with the increasing scanning speed. In addition, compared to the sequential discrete mode, the continuous scanning mode could achieve higher treatment efficiency (lesion area generated per second) with a lower peak temperature. The present studies suggest that the peak temperature and tissue lesion resulting from the HIFU exposure could be controlled by adjusting the transducer scanning speed, which is important for improving the HIFU treatment efficiency.

  12. Ultrasound scan in the diagnosis of neonatal renal candidiasis; Ecografia en el diagnostico de la candidiasis renal neonatal

    Energy Technology Data Exchange (ETDEWEB)

    Muro, D.; Sanguesa, C.; Torres, D.; Berbel, O.; Andres, V. [Hospital Infantil La Fe. Valencia (Spain)

    2003-07-01

    To describe the most pertinent echographic findings regarding systemic and renal candidiasis in high-risk neonates. Echographic findings and clinical histories of 40 neonates in the neonatal intensive care unit were retrospectively analyzed. Thirty-eight presented systemic candidiasis with renal participation, while two showed only renal candidiasis. Ultrasound scans were performed using 7.5 MHz probes. Alterations in renal echo structure, presence of echogenic material without acoustic shadowing in the excretory system (mycetoma), presence of lithiasis, pyonephrosis and associated renal malformations were all evaluated. Ten patients presented renal alterations in ultrasound scan. Six children had originally shown increased eye-catching in the renal parenchyma which was resolved after medical treatment. Four children presented renal mycetoma, and in two there were renal malformations. Both of these exhibited a profile for pyonephrosis. One patient with renal mycetoma without urological abnormalities developed a lithiasis. Surgical intervention was unnecessary in all cases. The most common echographic findings in immature high-risk low-weight patients with systemic and renal candidiasis were alterations in the eye-catching of renal parenchyma and the presence of mycetoma. (Author) 22 refs.

  13. Combined diagnosis of lateral cervical masses by RI-scintigraphy, ultrasound and CT-scanning

    International Nuclear Information System (INIS)

    Yang, Kuang-Tsuong; Yamashita, Toshio; Sasa, Hidehiko

    1984-01-01

    Careful palpation, plain X-rays and angiography are useful in the diagnosis of lateral cervical masses, but accurate preoperative evaluation sometimes needs further examinations. Recently several new auxiliary procedures have become available such as RI-scintigraphy, Ultrasound, and CT-scanning but even these may not be sufficient when used singly. When all these procedures were combined preoperatively in the case of lateral cervical masses and the results were compared with the findings at time of surgery and the pathology of the extirpated masses, acurate preoperative diagnose were possible. (author)

  14. B-lines with Lung Ultrasound: The Optimal Scan Technique at Rest and During Stress.

    Science.gov (United States)

    Scali, Maria Chiara; Zagatina, Angela; Simova, Iana; Zhuravskaya, Nadezhda; Ciampi, Quirino; Paterni, Marco; Marzilli, Mario; Carpeggiani, Clara; Picano, Eugenio

    2017-11-01

    Various lung ultrasound (LUS) scanning modalities have been proposed for the detection of B-lines, also referred to as ultrasound lung comets, which are an important indication of extravascular lung water at rest and after exercise stress echo (ESE). The aim of our study was to assess the lung water spatial distribution (comet map) at rest and after ESE. We performed LUS at rest and immediately after semi-supine ESE in 135 patients (45 women, 90 men; age 62 ± 12 y, resting left ventricular ejection fraction = 41 ± 13%) with known or suspected heart failure or coronary artery disease. B-lines were measured by scanning 28 intercostal spaces (ISs) on the antero-lateral chest, 2nd-5th IS, along with the midaxillary (MA), anterior axillary (AA), mid-clavicular (MC) and parasternal (PS) lines. Complete 28-region, 16-region (3rd and 4th IS), 8-region (3rd IS), 4-region (3rd IS, only AA and MA) and 1-region (left 3rd IS, MA) scans were analyzed. In each space, the B-lines were counted from 0 = black lung to 10 = white lung. Interpretable images were obtained in all spaces (feasibility = 100 %). B-lines (>0 in at least 1 space) were present at ESE in 93 patients (69%) and absent in 42. More B-lines were found in the 3rd IS and along AA and MA lines. The B-line cumulative distribution was symmetric at rest (right/left = 1.10) and asymmetric with left lung predominance during stress (right/left = 0.67). The correlation of per-patient B-line number between 28-S and 16-S (R 2  = 0.9478), 8-S (R 2  = 0.9478) and 4-S scan (R 2  = 0.9146) was excellent, but only good with 1-S (R 2  = 0.8101). The average imaging and online analysis time were 5 s per space. In conclusion, during ESE, the comet map of lung water accumulation follows a predictable spatial pattern with wet spots preferentially aligned with the third IS and along the AA and MA lines. The time-saving 4-region scan is especially convenient during stress, simply dismissing dry regions and

  15. Optical detection of ultrasound using an apertureless near-field scanning optical microscopy system

    Science.gov (United States)

    Ahn, Phillip; Zhang, Zhen; Sun, Cheng; Balogun, Oluwaseyi

    2013-01-01

    Laser ultrasonics techniques are power approaches for non-contact generation and detection of high frequency ultrasound on a local scale. In these techniques, optical diffraction limits the spatial information that can be accessed from a measurement. In order to improve the lateral spatial resolution, we incorporate an apertureless near-field scanning optical microscope (aNSOM) into laser ultrasonics setup for local detection of laser generated ultrasound. The aNSOM technique relies on the measurement of a weak backscattered near-field light intensity resulting from the oblique illumination of a nanoscale probe-tip positioned close to a sample surface. We enhance the optical near-field intensity by coupling light to surface plasmon polaritons (SPPs) on the shaft of an atomic force microscopy (AFM) cantilever. The SPPs propagate down the AFM shaft, localize at the tip apex, and are backscattered to the far-field when the separation distance between the probe tip and the sample surface is comparable to the probe-tip radius. The backscattered near-field intensity is dynamically modulated when an ultrasonic wave arrives at the sample surface leading to a transient change in the tip-sample separation distance. We present experimental results detailing measurement of broadband and narrowband laser generated ultrasound in solids with frequencies reaching up to 180 MHz range.

  16. Abdominal aortic aneurysm development in men following a "normal" aortic ultrasound scan.

    Science.gov (United States)

    Hafez, H; Druce, P S; Ashton, H A

    2008-11-01

    To determine predictors related to abdominal aortic aneurysm (AAA) development following a "normal" aortic ultrasound scan. Over a 23-year period, 22 961 men participated in an AAA screening programme. Maximum aortic diameter of less than 30 mm was deemed "normal". 4308 of these "normal" individuals were later re-scanned at intervals for research purposes. AAA prevalence was 4.4% at initial scanning. In those with a normal scan, 46 patients subsequently presented with AAAs incidentally detected and 120 (2.8%) had AAAs identified as part of the ongoing surveillance. The median initial aortic size of these 166 men was 25 mm (range 15-29 mm). Over the follow-up period, there have been 24 (14%) AAA-related deaths, 24 patients underwent successful AAA surgery and 36 died of unrelated causes. In those with an initial aortic diameter of <25 mm who later developed an AAA, the odds ratio for AAA-related mortality was 2 (95% CI 1-4.1, p=0.03, x(2)). AAAs can develop following an initial "normal" scan and men with an aortic diameters of 25-29 mm appear to be at greater risk. Surveillance for this sub-group may further reduce the incidence of undiagnosed AAA and AAA-related mortality.

  17. Safety and Efficacy of Scanning Ultrasound Treatment of Aged APP23 Mice

    Directory of Open Access Journals (Sweden)

    Gerhard Leinenga

    2018-02-01

    Full Text Available Deposition of amyloid-β (Aβ peptide leads to amyloid plaques that together with tau deposits characterize the brains of patients with Alzheimer's disease (AD. In modeling this pathology, transgenic animals such as the APP23 strain, that expresses a mutant form of the amyloid precursor protein found in familial cases of AD, have been instrumental. In previous studies, we have shown that repeated treatments with ultrasound in a scanning mode (termed scanning ultrasound or SUS were effective in removing Aβ and restoring memory functions, without the need for a therapeutic agent such as an Aβ antibody. Considering that age is the most important risk factor for AD, we extended this study in which the mice were only 12 months old at the time of treatment by assessing a cohort of 2 year-old mice. Interestingly, at this age, APP23 mice are characterized by cerebral amyloid angiopathy (CAA and the presence of occasional microbleeds. We found that SUS in aged mice that have been exposed to four SUS sessions that were spread out over 8 weeks and analyzed 4 weeks later did not show evidence of increased CAA or microbleeds. Furthermore, amyloid was reduced as assessed by methoxy-XO4 fluorescence. In addition, plaque-associated microglia were more numerous in SUS treated mice. Together this adds to the notion that SUS may be a treatment modality for human neurodegenerative diseases.

  18. Muscle metastases: ultrasound and CT scan imaging in nine cases. Report on 9 cases

    International Nuclear Information System (INIS)

    Folinais, D.; Cluzel, Ph.; Blangy, S.; Sibert, A.; David, M.; Benacerraf, R.

    1988-01-01

    Clinical, ultrasound and CT scan examinations were carried out in 9 patients with secondary muscle lesions. All muscles can be affected but there was a marked predominance of psoas lesions (6 of the 9 cases). Two contrasting clinical pictures are seen. Secondary muscle tumors can occur during evolution of a known treated cancer (5 of the 9 cases), revealed usually by large, rarely painful, mass. CT scan imaging shows an heterogeneous mass taking up contrast and often partially necrotic, the lesions appearing hypoechogenic or heterogeneous on ultrasound exmination. Certain lesions can be totally necrotic. In some cases (4 of the 9 patients) the muscle metastases revealed the presence of a tumor. Symptomatology may be atypical and lead to a delay in diagnosis. Fine needle puncture biopsy can detect the secondary origin of the muscle lesion and also the primary tumor site (4 out of 9 cases), bronchopulmonary and colon cancer predominating. Images are however non-specific and in the absence of NMR imaging the muscle or lymph node metastases can be confused, although this has no practic consequences since treatment is identical [fr

  19. Sustained effect of simulation-based ultrasound training on clinical performance: a randomized trial

    Science.gov (United States)

    Tolsgaard, M G; Ringsted, C; Dreisler, E; Nørgaard, L N; Petersen, J H; Madsen, M E; Freiesleben, N L C; Sørensen, J L; Tabor, A

    2015-01-01

    Objective To study the effect of initial simulation-based transvaginal sonography (TVS) training compared with clinical training only, on the clinical performance of residents in obstetrics and gynecology (Ob-Gyn), assessed 2 months into their residency. Methods In a randomized study, new Ob-Gyn residents (n = 33) with no prior ultrasound experience were recruited from three teaching hospitals. Participants were allocated to either simulation-based training followed by clinical training (intervention group; n = 18) or clinical training only (control group; n = 15). The simulation-based training was performed using a virtual-reality TVS simulator until an expert performance level was attained, and was followed by training on a pelvic mannequin. After 2 months of clinical training, one TVS examination was recorded for assessment of each resident's clinical performance (n = 26). Two ultrasound experts blinded to group allocation rated the scans using the Objective Structured Assessment of Ultrasound Skills (OSAUS) scale. Results During the 2 months of clinical training, participants in the intervention and control groups completed an average ± SD of 58 ± 41 and 63 ± 47 scans, respectively (P = 0.67). In the subsequent clinical performance test, the intervention group achieved higher OSAUS scores than did the control group (mean score, 59.1% vs 37.6%, respectively; P training leads to substantial improvement in clinical performance that is sustained after 2 months of clinical training. © 2015 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology. PMID:25580809

  20. Protocol of plain radiographs, hip ultrasound, and triple phase bone scans in the evaluation of the painful pediatric hip

    International Nuclear Information System (INIS)

    Alexander, J.E.; Seibert, J.J.; Aronson, J.; Williamson, S.L.; Glasier, C.M.; Rodgers, A.B.; Corbitt, S.L.

    1988-01-01

    A useful protocol for the evaluation of hip pain in the pediatric patient, using a combination of plain radiographs, hip ultrasound (US), and triple phase radionuclide bone scans is presented. Patients with hip pain were initially evaluated by plain radiographs of the pelvis and hips. If no diagnosis was reached, the hips were studied for effusions by real-time hip ultrasonography. If an effusion was present, the joint was aspirated for diagnosis. If no effusion was present by US or if no diagnosis was reached by aspiration, triple phase radionuclide bone scans were performed. Fifty patients were evaluated by this prospective protocol, and the diagnosis was reached in 48 of the 50 cases (10 by plain radiographs, 16 by US, and aspiration of the joint, and 22 by triple phase bone scans). Hip effusions were found in 20 patients by US, with no false positives or false negatives. Previous studies for detecting effusions by US have emphasized absolute measurements of the capsular width, but we report a typical appearance of the hip capsule when fluid is present (a bulging convex capsule). When no effusion is present, the capsule is concave and parallels the long axis of the femoral neck

  1. Comparison of CT scan and colour flow doppler ultrasound in detecting venous tumour thrombous in renal cell carcinoma

    International Nuclear Information System (INIS)

    Khan, A.R.; Anwar, K.

    2008-01-01

    Renal cell carcinoma has marked tendency to spread into renal vein, inferior vena cava and right side of heart. Extension of tumour thrombus into these veins will alter the surgical approach. We have compared the CT scan with Colour flow Doppler ultrasound in detecting venous tumour thrombus in renal vein and inferior vena cava. This cross-sectional study included 30 adult patients presenting with renal tumour. Patients of either gender were included in the study. Non probability convenience sampling was used. All patients underwent colour flow Doppler ultrasound and CT scan with contrast to asses the renal vein and inferior vena cava. The results were confirmed by intra operative findings and histopathology. The data was analyzed using SPSS version 12. Out of 30 patients, 20 (66%) were males and 10 (34%) female. The tumour was predominantly on the right side (60%), as was renal venous tumour thrombus (44%). Inferior vena cava was involved in 4 cases predominantly due to right sided tumours. The sensitivity of Doppler ultrasound in detecting renal venous tumour thrombus (88% on right and 100% on left side) was higher than CT scan (63% on right and 60% on left side). Doppler ultrasound was also superior to CT scan in detecting vena caval thrombus. The overall sensitivity of Doppler sonography was higher than CT scan in detecting tumour extension into renal veins and inferior vena cava. Therefore, it can be used as a complementary tool in equivocal cases. (author)

  2. Performance of the SRRC scanning photoelectron microscope

    Science.gov (United States)

    Hong, I.-H.; Lee, T.-H.; Yin, G.-C.; Wei, D.-H.; Juang, J.-M.; Dann, T.-E.; Klauser, R.; Chuang, T. J.; Chen, C. T.; Tsang, K.-L.

    2001-07-01

    A scanning photoelectron microscope has been constructed at SRRC. This SPEM system consists primarily of a Fresnel zone plate (ZP) with an order-selection aperture, a flexure scanning stage, a hemispherical electron analyzer, and sample/ZP insertion system. The flexure stage is used to scan the sample. A hemispherical analyzer with Omni V lens and a 16-channel multichannel detector (MCD) is used to collect photoelectrons. A set of 16 photoelectron images at different kinetic energies can be simultaneously acquired in one single scan. The data acquisition system is designed to collect up to 32 images concurrently, including 16 MCD signals, total electron yield and transmitted photon flux. The design and some initial test results of this SPEM station are presented and discussed.

  3. Performance of the SRRC scanning photoelectron microscope

    International Nuclear Information System (INIS)

    Hong, I.-H.; Lee, T.-H.; Yin, G.-C.; Wei, D.-H.; Juang, J.-M.; Dann, T.-E.; Klauser, R.; Chuang, T.J.; Chen, C.T.; Tsang, K.-L.

    2001-01-01

    A scanning photoelectron microscope has been constructed at SRRC. This SPEM system consists primarily of a Fresnel zone plate (ZP) with an order-selection aperture, a flexure scanning stage, a hemispherical electron analyzer, and sample/ZP insertion system. The flexure stage is used to scan the sample. A hemispherical analyzer with Omni V lens and a 16-channel multichannel detector (MCD) is used to collect photoelectrons. A set of 16 photoelectron images at different kinetic energies can be simultaneously acquired in one single scan. The data acquisition system is designed to collect up to 32 images concurrently, including 16 MCD signals, total electron yield and transmitted photon flux. The design and some initial test results of this SPEM station are presented and discussed

  4. Performance of the SRRC scanning photoelectron microscope

    CERN Document Server

    Hong, I H; Yin, G C; Wei, D H; Juang, J M; Dann, T E; Klauser, R; Chuang, T J; Chen, C T; Tsang, K L

    2001-01-01

    A scanning photoelectron microscope has been constructed at SRRC. This SPEM system consists primarily of a Fresnel zone plate (ZP) with an order-selection aperture, a flexure scanning stage, a hemispherical electron analyzer, and sample/ZP insertion system. The flexure stage is used to scan the sample. A hemispherical analyzer with Omni V lens and a 16-channel multichannel detector (MCD) is used to collect photoelectrons. A set of 16 photoelectron images at different kinetic energies can be simultaneously acquired in one single scan. The data acquisition system is designed to collect up to 32 images concurrently, including 16 MCD signals, total electron yield and transmitted photon flux. The design and some initial test results of this SPEM station are presented and discussed.

  5. Ultrasound

    Science.gov (United States)

    Ultrasound is a useful procedure for monitoring the baby's development in the uterus. Ultrasound uses inaudible sound waves to produce a two-dimensional image of the baby while inside the mother's ...

  6. Novel Automatic Detection of Pleura and B-lines (Comet-Tail Artifacts) on In-Vivo Lung Ultrasound Scans

    DEFF Research Database (Denmark)

    Moshavegh, Ramin; Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse

    2016-01-01

    This paper presents a novel automatic method for detection of B-lines (comet-tail artifacts) in lung ultrasound scans. B-lines are the most commonly used artifacts for analyzing the pulmonary edema. They appear as laser-like vertical beams, which arise from the pleural line and spread down without...

  7. How to learn and to perform endoscopic ultrasound and endobronchial ultrasound for lung cancer staging

    DEFF Research Database (Denmark)

    Konge, Lars; Colella, Sara; Vilmann, Peter

    2015-01-01

    The learning of transesophageal ultrasound guided fine needle aspiration (FNA) (endoscopic ultrasound-FNA), and endobronchial ultrasound guided transbronchial needle aspiration (endosonography) should be based on the following steps: Acquiring theoretical knowledge, training on simulators, and su...

  8. A 3D freehand ultrasound system for multi-view reconstructions from sparse 2D scanning planes.

    Science.gov (United States)

    Yu, Honggang; Pattichis, Marios S; Agurto, Carla; Beth Goens, M

    2011-01-20

    A significant limitation of existing 3D ultrasound systems comes from the fact that the majority of them work with fixed acquisition geometries. As a result, the users have very limited control over the geometry of the 2D scanning planes. We present a low-cost and flexible ultrasound imaging system that integrates several image processing components to allow for 3D reconstructions from limited numbers of 2D image planes and multiple acoustic views. Our approach is based on a 3D freehand ultrasound system that allows users to control the 2D acquisition imaging using conventional 2D probes.For reliable performance, we develop new methods for image segmentation and robust multi-view registration. We first present a new hybrid geometric level-set approach that provides reliable segmentation performance with relatively simple initializations and minimum edge leakage. Optimization of the segmentation model parameters and its effect on performance is carefully discussed. Second, using the segmented images, a new coarse to fine automatic multi-view registration method is introduced. The approach uses a 3D Hotelling transform to initialize an optimization search. Then, the fine scale feature-based registration is performed using a robust, non-linear least squares algorithm. The robustness of the multi-view registration system allows for accurate 3D reconstructions from sparse 2D image planes. Volume measurements from multi-view 3D reconstructions are found to be consistently and significantly more accurate than measurements from single view reconstructions. The volume error of multi-view reconstruction is measured to be less than 5% of the true volume. We show that volume reconstruction accuracy is a function of the total number of 2D image planes and the number of views for calibrated phantom. In clinical in-vivo cardiac experiments, we show that volume estimates of the left ventricle from multi-view reconstructions are found to be in better agreement with clinical

  9. Investigation into the quantitative and qualitative characteristics of choroidal melanoma through magnetic resonance imaging and B-scan ultrasound

    Directory of Open Access Journals (Sweden)

    Papayiannis V

    2017-08-01

    Full Text Available Vassilis Papayiannis,1 Konstantinos T Tsaousis,2,3 Constantinos A Kouskouras,4 Afroditi Haritanti,4 Vasilios F Diakonis,5 Ioannis T Tsinopoulos2 1Department of Radiology, Papageorgiou General Hospital, 2Department of Ophthalmology, Aristotle University of Thessaloniki, Thessaloniki, Greece; 3John A Moran Eye Center, University of Utah, Salt Lake City, UT, USA; 4Department of Radiology, AHEPA Aristotle University Hospital of Thessaloniki, Thessaloniki, Greece; 5Bascom Palmer Eye Institute, Miller School of Medicine, University of Miami, Miami, FL, USA Objective: To investigate the homogeneity and vascularity of choroidal melanoma through magnetic resonance imaging (MRI and brightness modulation (B-mode ultrasound scan and their correlation with dimensions of tumor, as well as to measure the sensitivity of both modalities in retinal detachment (RD detection.Materials and methods: This retrospective chart review included patients diagnosed with choroidal melanoma. All these patients underwent MRI scans using T2-weighted (T2-WI and T1-weighted (T1-WI sequences, before and after an intravenous injection of paramagnetic contrast material. The patients were also examined using a B-mode ultrasound scan, and the results from both modalities were compared (tumor homogeneity, tumor height, tumor base diameter, and tumor vascularity.Results: Forty-two patients (mean age =65.33±12.51 years with choroidal melanoma were included in the study. Homogeneity was confirmed in 16 patients through ultrasound scan, in 19 patients through T1-WI sequence, in 21 patients through T2-WI sequence, and in 25 patients through T1-WI sequence + contrast (gadolinium. Patients with homogenous tumors presented with lower (P=0.0045 mean height than that of those with nonhomogenous tumors, whereas no statistically significant difference was found for base diameter measurements (P=0.056. Patients with tumors of high vascularity presented with greater mean height (P=0.000638 and

  10. Comparison of the biometric formulas used for applanation A-scan ultrasound biometry.

    Science.gov (United States)

    Özcura, Fatih; Aktaş, Serdar; Sağdık, Hacı Murat; Tetikoğlu, Mehmet

    2016-10-01

    The purpose of the study was to compare the accuracy of various biometric formulas for predicting postoperative refraction determined using applanation A-scan ultrasound. This retrospective comparative study included 485 eyes that underwent uneventful phacoemulsification with intraocular lens (IOL) implantation. Applanation A-scan ultrasound biometry and postoperative manifest refraction were obtained in all eyes. Biometric data were entered into each of the five IOL power calculation formulas: SRK-II, SRK/T, Holladay I, Hoffer Q, and Binkhorst II. All eyes were divided into three groups according to axial length: short (≤22.0 mm), average (22.0-25.0 mm), and long (≥25.0 mm) eyes. The postoperative spherical equivalent was calculated and compared with the predicted refractive error using each biometric formula. The results showed that all formulas had significantly lower mean absolute error (MAE) in comparison with Binkhorst II formula (P < 0.01). The lowest MAE was obtained with the SRK-II for average (0.49 ± 0.40 D) and short (0.67 ± 0.54 D) eyes and the SRK/T for long (0.61 ± 0.50 D) eyes. The highest postoperative hyperopic shift was seen with the SRK-II for average (46.8 %), short (28.1 %), and long (48.4 %) eyes. The highest postoperative myopic shift was seen with the Holladay I for average (66.4 %) and long (71.0 %) eyes and the SRK/T for short eyes (80.6 %). In conclusion, the SRK-II formula produced the lowest MAE in average and short eyes and the SRK/T formula produced the lowest MAE in long eyes. The SRK-II has the highest postoperative hyperopic shift in all eyes. The highest postoperative myopic shift is with the Holladay I for average and long eyes and SRK/T for short eyes.

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  12. Acute pyelonephritis in pediatric age: comparative study between power Doppler ultrasound scan and DMSA; Pielonefritis aguda en la edad pediatrica: estudio comparative entre la ecografiapower-Doppler y el DMSA

    Energy Technology Data Exchange (ETDEWEB)

    Muro, M. D.; Sanguesa, C.; Otero, M. C.; Piqueras, A. I.; Lloret, M. T. [Hospital Infantil Universitario La Fe. Valencia (Spain)

    2002-07-01

    To evaluate the usefulness of power Doppler (PD) Ultrasound Scan in the study of acute pyelonephritis (APN). To compare ultrasound scan results with those obtained with renal gammagraphy (DMSA). To relate the findings to the clinical criteria and to determine the presence of vesicoureteral reflux (VUR) in the serial micturition cystography (SMC). Prospective study of 92 patients (ages between 1 month and 10 years) with suspected clinical PNA. All children were initially subjected to PD ultrasound scan and DMSA. Those under 3 years old were also subjected to SMC for the study of VUR. PNA in the PD ultrasound scan was manifested by decrease in vascularisation and in the DMSA by decrease in caption in the affected zones. 87 renal units (RU) with PNA foci were detected. Conformity between the PD ultrasound scan and DMSA was 157 RU (92%): 52 positives, 22 negatives with PNA and 83 normal RU. The sensitivities of PD and DMSA were 65.5% and 69.0%. 51 SMC were performed, with VUR being detected in 18 (13 bilateral and 5 unilateral), in which the sensitivities of PD and DMSA were 65.5% and 69.0%. 51 SMC were performed, with VUR being detected in 18 (13 bilateral and 5 unilateral), in which the sensitivities of PD and DMSA were 80% and 85%, respectively. Mode B ultrasound scan and PD can replace DMSA in the initial study of PPNA. It is non-invasive, simple, economical and just as reliable as DMSA in expert hands. it can also postpone by up to 6 months the need to perform DMSA for detection of permanent renal damage. (Author) 22 refs.

  13. Whole Body Bone Scan Findings after High Intensity Focused Ultrasound (HIFU) Treatment

    International Nuclear Information System (INIS)

    Seo, Ye Young; O, Joo Hyun; Sohn, Hyung Sun; Choi, Eun Kyoung; Yoo, Ik Dong; Oh, Jin Kyoung; Han, Eun Ji; Jung, Seung Eun; Kim, Sung Hoon

    2011-01-01

    This study aims to examine the findings of 99mT c diphosphonate bone scans in cancer patients with a history of HIFU treatment. Bone scan images of patients with a history of HIFU treatment for primary of metastatic cancer from January 2006 to July 2010 were retrospectively reviewed. Cases of primary bone tumor or HIFU treatment reaching only the superficial soft tissue layer were excluded. Bone scan images of 62 patients (26 female, 36 male; mean age 57±9 years) were studied. HIFU treatment was performed in the liver (n=40), pancreas (n=40), pancreas (n=16), and breast (n=6). Mean interval time between HIFU treatment and bone scan was 106±105 days (range: 1-572 days). Of 62 scans, 43 showed diffusely decreased uptake of bone within the path of HIFU treatment: antero axillary and/or posterior arcs of right 5th to 11th ribs in 34 cases after treatment of hepatic lesions; anterior arcs of 2nd to 5th ribs in 5 cases after treatment for breast tumors; and posterior arcs of left 9th to 11th ribs or thoraco lumbar vertebrae in 4 cases after treatment for pancreas tumor. Of 20 patients who had bone scans more than twice, five showed recovered uptake of the radiotracer in the involved ribs in the follow up bone scan. Of 62 bone scans in patients with a history of HIFU treatment for primary of metastatic cancer, 69% presented diffusely decreased uptake in the bone in the path of HIFU treatment.

  14. Ultrasound as a Screening Tool for Performing Caudal Epidural Injections

    International Nuclear Information System (INIS)

    Nikooseresht, Mahshid; Hashemi, Masoud; Mohajerani, Seyed Amir; Shahandeh, Farideh; Agah, Mahvash

    2014-01-01

    The caudal approach to the epidural space has been used for decades to treat low back pain caused by lumbosacral root compression. The use of fluoroscopy during epidural steroid injection is the preferred method for placing the needle more accurately in the sacral hiatus, but it carries the risk of radiation hazard. The aim of the study was to assess the anatomical structure of the sacral hiatus and the feasibility of caudal epidural injections under ultrasound guidance. Two hundred and forty patients (male = 100, female = 140) with low back pain and sciatica who were candidates for caudal epidural injection were enrolled into this study. Ultrasound images of the sacral hiatus and bilateral cornua were obtained by a real-time linear array ultrasound transducer. The distance between bilateral cornua and the anterior and posterior wall of the sacrum were measured at the base (sacral hiatus). Under the guide of ultrasonography, we defined the injection successful if turbulence of medication fluid was observed in the sacral canal, but correct placement of the needle and injectant was confirmed on fluoroscopic view as the gold standard technique. The epidurogram showed that the injection was successful in 230 of the 240 patients (95.8%). In eight patients, the injection was not in the correct place in the sacral canal. The sacral hiatus could not be identified by ultrasound images in only two patients who had a closed sacral hiatus identified by fluoroscopy. The mean distance of the sacral hiatus was 4.7 ± 1.7 mm and the mean distance between bilateral cornua was 18.0 ± 2.8 mm. The mean duration of the procedure was 10.8 ± 6.8 minutes. No major complication was observed in the next month. In conclusion, ultrasound could be used as a safe, fast and reliable modality to observe the anatomic variation of the sacral hiatus and to perform caudal epidural injections

  15. Assessment of performance measures and learning curves for use of a virtual-reality ultrasound simulator in transvaginal ultrasound examination

    DEFF Research Database (Denmark)

    Madsen, M E; Konge, L; Nørgaard, L N

    2014-01-01

    OBJECTIVE: To assess the validity and reliability of performance measures, develop credible performance standards and explore learning curves for a virtual-reality simulator designed for transvaginal gynecological ultrasound examination. METHODS: A group of 16 ultrasound novices, along with a group......-6), corresponding to an average of 219 min (range, 150-251 min) of training. The test/retest reliability was high, with an intraclass correlation coefficient of 0.93. CONCLUSIONS: Competence in the performance of gynecological ultrasound examination can be assessed in a valid and reliable way using virtual-reality...

  16. Investigation into the quantitative and qualitative characteristics of choroidal melanoma through magnetic resonance imaging and B-scan ultrasound.

    Science.gov (United States)

    Papayiannis, Vassilis; Tsaousis, Konstantinos T; Kouskouras, Constantinos A; Haritanti, Afroditi; Diakonis, Vasilios F; Tsinopoulos, Ioannis T

    2017-01-01

    To investigate the homogeneity and vascularity of choroidal melanoma through magnetic resonance imaging (MRI) and brightness modulation (B-mode) ultrasound scan and their correlation with dimensions of tumor, as well as to measure the sensitivity of both modalities in retinal detachment (RD) detection. This retrospective chart review included patients diagnosed with choroidal melanoma. All these patients underwent MRI scans using T2-weighted (T2-WI) and T1-weighted (T1-WI) sequences, before and after an intravenous injection of paramagnetic contrast material. The patients were also examined using a B-mode ultrasound scan, and the results from both modalities were compared (tumor homogeneity, tumor height, tumor base diameter, and tumor vascularity). Forty-two patients (mean age=65.33±12.51 years) with choroidal melanoma were included in the study. Homogeneity was confirmed in 16 patients through ultrasound scan, in 19 patients through T1-WI sequence, in 21 patients through T2-WI sequence, and in 25 patients through T1-WI sequence + contrast (gadolinium). Patients with homogenous tumors presented with lower ( P =0.0045) mean height than that of those with nonhomogenous tumors, whereas no statistically significant difference was found for base diameter measurements ( P =0.056). Patients with tumors of high vascularity presented with greater mean height ( P =0.000638) and greater mean base diameter compared with those with tumors of low vascularity ( P =0.019543). RD was detected in 26 patients through T1-WI sequence, in 13 patients through T2-WI sequence, in 26 patients through T1-WI sequence + contrast, and in 32 patients through ultrasound scan, which proved to be the most sensitive modality. The height of choroidal melanoma was positively correlated with tumor's homogeneity. Melanomas of greater height were found to be less homogenous, due to increased degeneration and higher occurrence of intratumoral hemorrhage. In addition, choroidal melanoma's height was also

  17. Fluid mechanics of blood flow in human fetal left ventricles based on patient-specific 4D ultrasound scans.

    Science.gov (United States)

    Lai, Chang Quan; Lim, Guat Ling; Jamil, Muhammad; Mattar, Citra Nurfarah Zaini; Biswas, Arijit; Yap, Choon Hwai

    2016-10-01

    The mechanics of intracardiac blood flow and the epigenetic influence it exerts over the heart function have been the subjects of intense research lately. Fetal intracardiac flows are especially useful for gaining insights into the development of congenital heart diseases, but have not received due attention thus far, most likely because of technical difficulties in collecting sufficient intracardiac flow data in a safe manner. Here, we circumvent such obstacles by employing 4D STIC ultrasound scans to quantify the fetal heart motion in three normal 20-week fetuses, subsequently performing 3D computational fluid dynamics simulations on the left ventricles based on these patient-specific heart movements. Analysis of the simulation results shows that there are significant differences between fetal and adult ventricular blood flows which arise because of dissimilar heart morphology, E/A ratio, diastolic-systolic duration ratio, and heart rate. The formations of ventricular vortex rings were observed for both E- and A-wave in the flow simulations. These vortices had sufficient momentum to last until the end of diastole and were responsible for generating significant wall shear stresses on the myocardial endothelium, as well as helicity in systolic outflow. Based on findings from previous studies, we hypothesized that these vortex-induced flow properties play an important role in sustaining the efficiency of diastolic filling, systolic pumping, and cardiovascular flow in normal fetal hearts.

  18. Investigation of infant brain with or without hydrocephalous in our environment using anterior transfontanelle ultrasound scan

    Directory of Open Access Journals (Sweden)

    Tobechukwu T Marchie

    2013-01-01

    Full Text Available Aim: A prospective study aimed to suggest easy and simple reproducible ventricular site that will be basic measurement plane and normal dimension determined, correlated to sizes of infants for comparative evaluation of hydrocephalous infants and should be reproducible in follow-up. Materials and Methods: A prospective study done in University of Benin Teaching Hospital Benin, Nigeria. This study used 50 consecutive infants with Ultrasound scan (US diagnosis of hydrocephalus and a control group of 50 US normal from 1 st January 2007 to 30 th June 2008. The infants were scan through the mid-patent anterior fontanelle in sagittal, and transverse planes with minor angulations to properly outline the ventricles and the position of measurement determined at the foramen of Monro of lateral ventricles and the diameter measured. The infants′ weight, crown-heel length, and head circumference were measured and body mass index (BMI calculated and correlated to lateral ventricular measurement. Data analysis was conducted using the Statistical Package for Social Sciences (SPSS Inc, USA, Version 11.0. Results: There was no statistically sex and age-related difference. There is statistically comparative high mean weight and height and lower BMI in hydrocephalic infants as against the control group (P < 0.001. The mean head circumference for hydrocephalus was 45.6 (± 10.5 standard deviation [SD], whereas the control group was 35.9 (± 2.7 SD with P < 0.001. The mean diameter of the anterior horn of left and right lateral ventricles at the level of foramen of Monro in hydrocephalic subjects is 18.4 mm ± 14.3 mm and 20.1 mm ± 16.8 mm with median diameter of 14.1 mm and 15.2 mm, respectively, whereas control group is 2.5 mm ± 0.6 mm and 2.5 mm ± 0.7 mm with median diameter of 2.5 mm and 2.4 mm, respectively. Conclusion: Transfontanelle US was found highly useful in investigation of hydrocephalous in infant.

  19. Thermal therapy for breast tumors by using a cylindrical ultrasound phased array with multifocus pattern scanning: a preliminary numerical study

    International Nuclear Information System (INIS)

    Ho, C-S; Ju, K-C; Cheng, T-Y; Chen, Y-Y; Lin, W-L

    2007-01-01

    The purpose of this study is to investigate the feasibility of using a 1 MHz cylindrical ultrasound phased array with multifocus pattern scanning to produce uniform heating for breast tumor thermal therapy. The breast was submerged in water and surrounded by the cylindrical ultrasound phased array. A multifocus pattern was generated and electrically scanned by the phased array to enlarge the treatment lesion in single heating. To prevent overheating normal tissues, a large planning target volume (PTV) would be divided into several planes with several subunits on each plane and sequentially treated with a cooling phase between two successive heatings of the subunit. Heating results for different target temperatures (T tgt ), blood perfusion rates and sizes of the PTV have been studied. Furthermore, a superficial breast tumor with different water temperatures was also studied. Results indicated that a higher target temperature would produce a slightly larger thermal lesion, and a higher blood perfusion rate would not affect the heating lesion size but increase the heating time significantly. The acoustic power deposition and temperature elevations in ribs can be minimized by orienting the acoustic beam from the ultrasound phased array approximately parallel to the ribs. In addition, a large acoustic window on the convex-shaped breast surface for the proposed ultrasound phased array and the cooling effect of water would prevent the skin overheating for the production of a lesion at any desired location. This study demonstrated that the proposed cylindrical ultrasound phased array can provide effective heating for breast tumor thermal therapy without overheating the skin and ribs within a reasonable treatment time

  20. Ultrasound

    Science.gov (United States)

    ... completed. Young children may need additional preparation. When scheduling an ultrasound for yourself or your child, ask ... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization ...

  1. Intracavitary ultrasound impairs left ventricular performance: presumed role of endocardial endothelium

    NARCIS (Netherlands)

    Gillebert, T. C.; de Hert, S. G.; Andries, L. J.; Jageneau, A. H.; Brutsaert, D. L.

    1992-01-01

    Irradiation of isolated cardiac muscle by high-power, high-frequency, continuous wave ultrasound selectively damages endocardial endothelium (EE). We evaluated this ultrasound effect in vivo on the performance of the intact ejecting canine left ventricle (LV). A cylindrical ultrasound probe (0.9

  2. Diagnosing and staging of cystic echinococcosis: how do CT and MRI perform in comparison to ultrasound?

    Directory of Open Access Journals (Sweden)

    Marija Stojkovic

    Full Text Available BACKGROUND: Imaging plays the key role in diagnosing and staging of CE. The description of CE-specific imaging features and the WHO CE cyst classification is based on ultrasound. The reproducibility of the ultrasound-defined features of CE cysts is variable in MR- and CT-imaging. This is of particular importance for cysts that are not accessible by US and because of the increasing availability and overuse of CT and MR imaging. METHODOLOGY/PRINCIPAL FINDINGS: Retrospective analysis of patients with abdominal CE cysts of an interdisciplinary CE clinic who had CT and/or MRI scans performed additionally to US imaging. All images were read and interpreted by the same senior radiologist experienced in the diagnosis of CE. US, CT and MR images were staged according to the WHO classification criteria. The agreement beyond chance was quantified by kappa coefficients (κ. 107 patients with 187 CE cysts met the inclusion criteria. All cysts were assessed by US, 138 by CT, and 125 by MRI. The level of agreement beyond chance of the individual CE stages 1-4 was clearly lower for CT, with κ ranging from 0.62 to 0.72, compared to MRI with values of κ between 0.83 and 1.0. For CE5 cysts CT (κ = 0.95 performed better than MRI (κ = 0.65. CONCLUSIONS: Ultrasound remains the corner stone of diagnosis, staging and follow up of CE cysts. MRI reproduces the ultrasound-defined features of CE better than CT. If US cannot be performed due to cyst location or patient-specific reasons MRI with heavily T2-weighted series is preferable to CT.

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures of the inside of ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  4. Combined Scanning Confocal Ultrasound Diagnostic and Treatment System for Bone Quality Assessment and Fracture Healing

    Data.gov (United States)

    National Aeronautics and Space Administration — The objectives of this study are to develop a combined diagnostic and treatment ultrasound technology for early prediction of bone disorder and guided acceleration...

  5. Preferences for a third-trimester ultrasound scan in a low-risk obstetric population: a discrete choice experiment.

    Science.gov (United States)

    Lynn, Fiona A; Crealey, Grainne E; Alderdice, Fiona A; McElnay, James C

    2015-10-01

    Establish maternal preferences for a third-trimester ultrasound scan in a healthy, low-risk pregnant population. Cross-sectional study incorporating a discrete choice experiment. A large, urban maternity hospital in Northern Ireland. One hundred and forty-six women in their second trimester of pregnancy. A discrete choice experiment was designed to elicit preferences for four attributes of a third-trimester ultrasound scan: health-care professional conducting the scan, detection rate for abnormal foetal growth, provision of non-medical information, cost. Additional data collected included age, marital status, socio-economic status, obstetric history, pregnancy-specific stress levels, perceived health and whether pregnancy was planned. Analysis was undertaken using a mixed logit model with interaction effects. Women's preferences for, and trade-offs between, the attributes of a hypothetical scan and indirect willingness-to-pay estimates. Women had significant positive preference for higher rate of detection, lower cost and provision of non-medical information, with no significant value placed on scan operator. Interaction effects revealed subgroups that valued the scan most: women experiencing their first pregnancy, women reporting higher levels of stress, an adverse obstetric history and older women. Women were able to trade on aspects of care and place relative importance on clinical, non-clinical outcomes and processes of service delivery, thus highlighting the potential of using health utilities in the development of services from a clinical, economic and social perspective. Specifically, maternal preferences exhibited provide valuable information for designing a randomized trial of effectiveness and insight for clinical and policy decision makers to inform woman-centred care. © 2013 Blackwell Publishing Ltd.

  6. Diagnostic performance of shear wave elastography of the breast according to scanning orientation.

    Science.gov (United States)

    Kim, Solip; Choi, SeonHyeong; Choi, Yoonjung; Kook, Shin-Ho; Park, Hee Jin; Chung, Eun Chul

    2014-10-01

    To evaluate the influence of the scanning orientation on diagnostic performance measured by the mean elasticity, maximum elasticity, and fat-to-lesion elasticity ratio on ultrasound-based shear wave elastography in differentiating breast cancers from benign lesions. In this study, a total of 260 breast masses from 235 consecutive patients were observed from March 2012 to November 2012. For each lesion, the mean elasticity value, maximum elasticity value, and fat-to-lesion ratio were measured along two orthogonal directions, and all values were compared with pathologic results. There were 59 malignant and 201 benign lesions. Malignant masses showed higher mean elasticity, maximum elasticity, and fat-to-lesion ratio values than benign lesions (P masses; and mean elasticity, 0.392, for anterior mammary fat. Mean elasticity, maximum elasticity, and fat-to-lesion elasticity ratio values were helpful in differentiating benign and malignant breast masses. The scanning orientation did not significantly affect the diagnostic performance of shear wave elastography for breast masses. © 2014 by the American Institute of Ultrasound in Medicine.

  7. Efficient high-performance ultrasound beamforming using oversampling

    Science.gov (United States)

    Freeman, Steven R.; Quick, Marshall K.; Morin, Marc A.; Anderson, R. C.; Desilets, Charles S.; Linnenbrink, Thomas E.; O'Donnell, Matthew

    1998-05-01

    High-performance and efficient beamforming circuitry is very important in large channel count clinical ultrasound systems. Current state-of-the-art digital systems using multi-bit analog to digital converters (A/Ds) have matured to provide exquisite image quality with moderate levels of integration. A simplified oversampling beamforming architecture has been proposed that may a low integration of delta-sigma A/Ds onto the same chip as digital delay and processing circuitry to form a monolithic ultrasound beamformer. Such a beamformer may enable low-power handheld scanners for high-end systems with very large channel count arrays. This paper presents an oversampling beamformer architecture that generates high-quality images using very simple; digitization, delay, and summing circuits. Additional performance may be obtained with this oversampled system for narrow bandwidth excitations by mixing the RF signal down in frequency to a range where the electronic signal to nose ratio of the delta-sigma A/D is optimized. An oversampled transmit beamformer uses the same delay circuits as receive and eliminates the need for separate transmit function generators.

  8. Performance evaluation of a rectifier column using gamma column scanning

    Directory of Open Access Journals (Sweden)

    Aquino Denis D.

    2017-12-01

    Full Text Available Rectifier columns are considered to be a critical component in petroleum refineries and petrochemical processing installations as they are able to affect the overall performance of these facilities. It is deemed necessary to monitor the operational conditions of such vessels to optimize processes and prevent anomalies which could pose undesired consequences on product quality that might lead to huge financial losses. A rectifier column was subjected to gamma scanning using a 10-mCi Co-60 source and a 2-inch-long detector in tandem. Several scans were performed to gather information on the operating conditions of the column under different sets of operating parameters. The scan profiles revealed unexpected decreases in the radiation intensity at vapour levels between trays 2 and 3, and between trays 4 and 5. Flooding also occurred during several scans which could be attributed to parametric settings.

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does ...

  10. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions.

    Science.gov (United States)

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure.

  11. The use of real time ultrasound scanning as a teaching method of anatomy in an undergraduate sonography and medical imaging degree in an Australian university

    International Nuclear Information System (INIS)

    Bowman, A.; Lawson, C.; McKillup, S.

    2016-01-01

    Background: Real-time ultrasound scanning is increasing in popularity as a teaching tool for human anatomy because it is non-invasive, offers real-time 3-D anatomy and is cheaper than dissections. Aim: To assess real-time ultrasound scanning as a teaching method of human anatomy, and to determine what teaching methods medical imaging and sonography students consider effective for understanding human anatomy. Method: Surveys were distributed to two consecutive cohorts of first year medical imaging and medical sonography students at CQUniversity. Participation was voluntary. Comparisons among teaching methods were made using repeated measures ANOVA. Results: Real-time ultrasound scanning was the most preferred method of delivery for anatomy classes overall especially compared to computer programs, videos, 3-D radiological images and dissection. Specifically, students indicated that ultrasound scanning was the preferred method to encourage learning from experience (F 7,231  = 2.942, p = 0.006), to develop team skills (F 7,231  = 4.550, p < 0.006), to follow complex instructions (F 7,231  = 4.656 p < 0.001) and to appreciate anatomical variation (F 7,231  = 2.067, p = 0.048). Dissection was the least favoured teaching method. Conclusion: Real-time ultrasound scanning is a useful tool for teaching anatomy, and animal dissections are a poor substitute for the use of human cadavers. - Highlights: • Real-time ultrasound scanning is a valid teaching tool for human anatomy. • Real-time ultrasound is preferred by students compared to other teaching methods. • Dissection is the least favoured method to learn anatomy. • Ultrasound encourages learning from experience and develops team skills.

  12. Tissue ablation accelerated by peripheral scanning mode with high-intensity focused ultrasound: a study on isolated porcine liver perfusion.

    Science.gov (United States)

    Bu, Rui; Yin, Li; Yang, Han; Wang, Qi; Wu, Feng; Zou, Jian Zhong

    2013-08-01

    The aims of this study were to investigate the feasibility of accelerated tissue ablation using a peripheral scanning mode with high-intensity focused ultrasound (HIFU) and to explore the effect of flow rate on total energy consumption of the target tissues. Using a model of isolated porcine liver perfusion via the portal vein and hepatic artery, we conducted a scanning protocol along the periphery of the target tissues using linear-scanned HIFU to carefully adjust the varying focal depth, generator power, scanning velocity and line-by-line interval over the entire ablation range. Porcine livers were divided into four ablation groups: group 1, n = 12, with dual-vessel perfusion; group 2, n = 11, with portal vein perfusion alone; group 3, n = 10, with hepatic artery perfusion alone; and group 4, n = 11, control group with no-flow perfusion. The samples were cut open consecutively at a thickness of 3 mm, and the actual ablation ranges were calculated along the periphery of the target tissues after triphenyl tetrazolium chloride staining. Total energy consumption was calculated as the sum of the energy requirements at various focal depths in each group. On the basis of the pre-supposed scanning protocol, the peripheral region of the target tissue formed a complete coagulation necrosis barrier in each group with varying dose combinations, and the volume of the peripheral necrotic area did not differ significantly among the four groups (p > 0.05). Furthermore, total energy consumption in each group significantly decreased with the corresponding decrease in flow rate (p Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. Fluid mechanics of human fetal right ventricles from image-based computational fluid dynamics using 4D clinical ultrasound scans.

    Science.gov (United States)

    Wiputra, Hadi; Lai, Chang Quan; Lim, Guat Ling; Heng, Joel Jia Wei; Guo, Lan; Soomar, Sanah Merchant; Leo, Hwa Liang; Biwas, Arijit; Mattar, Citra Nurfarah Zaini; Yap, Choon Hwai

    2016-12-01

    There are 0.6-1.9% of US children who were born with congenital heart malformations. Clinical and animal studies suggest that abnormal blood flow forces might play a role in causing these malformation, highlighting the importance of understanding the fetal cardiovascular fluid mechanics. We performed computational fluid dynamics simulations of the right ventricles, based on four-dimensional ultrasound scans of three 20-wk-old normal human fetuses, to characterize their flow and energy dynamics. Peak intraventricular pressure gradients were found to be 0.2-0.9 mmHg during systole, and 0.1-0.2 mmHg during diastole. Diastolic wall shear stresses were found to be around 1 Pa, which could elevate to 2-4 Pa during systole in the outflow tract. Fetal right ventricles have complex flow patterns featuring two interacting diastolic vortex rings, formed during diastolic E wave and A wave. These rings persisted through the end of systole and elevated wall shear stresses in their proximity. They were observed to conserve ∼25.0% of peak diastolic kinetic energy to be carried over into the subsequent systole. However, this carried-over kinetic energy did not significantly alter the work done by the heart for ejection. Thus, while diastolic vortexes played a significant role in determining spatial patterns and magnitudes of diastolic wall shear stresses, they did not have significant influence on systolic ejection. Our results can serve as a baseline for future comparison with diseased hearts. Copyright © 2016 the American Physiological Society.

  14. Predicting need for additional CT scan in children with a non-diagnostic ultrasound for appendicitis in the emergency department.

    Science.gov (United States)

    Nishizawa, Takuya; Maeda, Shigenobu; Goldman, Ran D; Hayashi, Hiroyuki

    2018-01-01

    This study aimed to determine which children with suspected appendicitis should be considered for a computerized tomography (CT) scan after a non-diagnostic ultrasound (US) in the Emergency Department (ED). We retrospectively reviewed patients 0-18year old, who presented to the ED with complaints of abdominal pain, during 2011-2015 and while in the hospital had both US and CT. We recorded demographic and clinical data and outcomes, and used univariate and multivariate methods for comparing patients who did and didn't have appendicitis on CT after non-diagnostic US. Multivariate analysis was performed using logistic regression to determine what variables were independently associated with appendicitis. A total of 328 patients were enrolled, 257 with non-diagnostic US (CT: 82 had appendicitis, 175 no-appendicitis). Younger children and those who reported vomiting or had right lower abdominal quadrant (RLQ) tenderness, peritoneal signs or White Blood Cell (WBC) count >10,000 in mm 3 were more likely to have appendicitis on CT. RLQ tenderness (Odds Ratio: 2.84, 95%CI: 1.07-7.53), peritoneal signs (Odds Ratio: 11.37, 95%CI: 5.08-25.47) and WBC count >10,000 in mm 3 (Odds Ratio: 21.88, 95%CI: 7.95-60.21) remained significant after multivariate analysis. Considering CT with 2 or 3 of these predictors would have resulted in sensitivity of 94%, specificity of 67%, positive predictive value of 57% and negative predictive value of 96% for appendicitis. Ordering CT should be considered after non-diagnostic US for appendicitis only when children meet at least 2 predictors of RLQ tenderness, peritoneal signs and WBC>10,000 in mm 3 . Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Technical tips to perform safe and effective ultrasound guided steroid joint injections in children.

    Science.gov (United States)

    Parra, Dimitri A

    2015-01-01

    The aim of this article is to describe the technique used to perform ultrasound guided steroid joint injections in children in a group of joints that can be injected using ultrasound as the only image guidance modality. The technique is described and didactic figures are provided to illustrate key technical concepts. It is very important to be familiar with the sonographic appearance of the pediatric joints and the developing bone when performing ultrasound-guided joint injections in children.

  16. Power Doppler ultrasonography and synovitis: correlating ultrasound imaging with histopathological findings and evaluating the performance of ultrasound equipments.

    Science.gov (United States)

    Koski, J M; Saarakkala, S; Helle, M; Hakulinen, U; Heikkinen, J O; Hermunen, H

    2006-12-01

    To examine the validity of power Doppler ultrasound imaging to identify synovitis, using histopathology as gold standard, and to assess the performance of ultrasound equipments. 44 synovial sites in small and large joints, bursae and tendon sheaths were depicted with ultrasound. A synovial biopsy was performed on the site depicted and a synovial sample was taken for histopathological evaluation. The performance of three ultrasound devices was tested using flow phantoms. A positive Doppler signal was detected in 29 of 35 (83%) of the patients with active histological inflammation. In eight additional samples, histological examination showed other pathological synovial findings and a Doppler signal was detected in five of them. No significant correlation was found between the amount of Doppler signal and histological synovitis score (r = 0.239, p = NS). The amount of subsynovial infiltration of polymorphonuclear leucocytes and surface fibrin correlated significantly with the amount of power Doppler signal: r = 0.397 (pultrasound devices differed in showing the smallest detectable flow. A negative Doppler signal does not exclude the possibility of synovitis. A positive Doppler signal in the synovium is an indicator of an active synovial inflammation in patients. A Doppler signal does not correlate with the extent of the inflammation and it can also be seen in other synovial reactions. It is important that the quality measurements of ultrasound devices are reported, because the results should be evaluated against the quality of the device used.

  17. Practice guideline for the performance of breast ultrasound elastography

    Directory of Open Access Journals (Sweden)

    Su Hyun Lee

    2014-01-01

    Full Text Available

    Ultrasound (US elastography is a valuable imaging technique for tissue characterization. Two main types of elastography, strain and shear-wave, are commonly used to image breast tissue. The use of elastography is expected to increase, particularly with the increased use of US for breast screening. Recently, the US elastographic features of breast masses have been incorporated into the 2nd edition of the Breast Imaging Reporting and Data System (BI-RADS US lexicon as associated findings. This review suggests practical guidelines for breast US elastography in consensus with the Korean Breast Elastography Study Group, which was formed in August 2013 to perform a multicenter prospective study on the use of elastography for US breast screening. This article is focused on the role of elastography in combination with B-mode US for the evaluation of breast masses. Practical tips for adequate data acquisition and the interpretation of elastography results are also presented.

  18. Practice guideline for the performance of breast ultrasound elastography.

    Science.gov (United States)

    Lee, Su Hyun; Chang, Jung Min; Cho, Nariya; Koo, Hye Ryoung; Yi, Ann; Kim, Seung Ja; Youk, Ji Hyun; Son, Eun Ju; Choi, Seon Hyeong; Kook, Shin Ho; Chung, Jin; Cha, Eun Suk; Park, Jeong Seon; Jung, Hae Kyoung; Ko, Kyung Hee; Choi, Hye Young; Ryu, Eun Bi; Moon, Woo Kyung

    2014-01-01

    Ultrasound (US) elastography is a valuable imaging technique for tissue characterization. Two main types of elastography, strain and shear-wave, are commonly used to image breast tissue. The use of elastography is expected to increase, particularly with the increased use of US for breast screening. Recently, the US elastographic features of breast masses have been incorporated into the 2nd edition of the Breast Imaging Reporting and Data System (BI-RADS) US lexicon as associated findings. This review suggests practical guidelines for breast US elastography in consensus with the Korean Breast Elastography Study Group, which was formed in August 2013 to perform a multicenter prospective study on the use of elastography for US breast screening. This article is focused on the role of elastography in combination with B-mode US for the evaluation of breast masses. Practical tips for adequate data acquisition and the interpretation of elastography results are also presented.

  19. Practice guideline for the performance of breast ultrasound elastography

    International Nuclear Information System (INIS)

    Lee, Su Hyun; Chang, Jung Min; Cho, Nariya

    2014-01-01

    Ultrasound (US) elastography is a valuable imaging technique for tissue characterization. Two main types of elastography, strain and shear-wave, are commonly used to image breast tissue. The use of elastography is expected to increase, particularly with the increased use of US for breast screening. Recently, the US elastographic features of breast masses have been incorporated into the 2nd edition of the Breast Imaging Reporting and Data System (BI-RADS) US lexicon as associated findings. This review suggests practical guidelines for breast US elastography in consensus with the Korean Breast Elastography Study Group, which was formed in August 2013 to perform a multicenter prospective study on the use of elastography for US breast screening. This article is focused on the role of elastography in combination with B-mode US for the evaluation of breast masses. Practical tips for adequate data acquisition and the interpretation of elastography results are also presented.

  20. Practice guideline for the performance of breast ultrasound elastography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Su Hyun; Chang, Jung Min; Cho, Nariya [Dept. of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); and others

    2014-03-15

    Ultrasound (US) elastography is a valuable imaging technique for tissue characterization. Two main types of elastography, strain and shear-wave, are commonly used to image breast tissue. The use of elastography is expected to increase, particularly with the increased use of US for breast screening. Recently, the US elastographic features of breast masses have been incorporated into the 2nd edition of the Breast Imaging Reporting and Data System (BI-RADS) US lexicon as associated findings. This review suggests practical guidelines for breast US elastography in consensus with the Korean Breast Elastography Study Group, which was formed in August 2013 to perform a multicenter prospective study on the use of elastography for US breast screening. This article is focused on the role of elastography in combination with B-mode US for the evaluation of breast masses. Practical tips for adequate data acquisition and the interpretation of elastography results are also presented.

  1. Ultrasound for Appendicitis: Performance and Integration with Clinical Parameters

    Science.gov (United States)

    Löfvenberg, Fanny

    2016-01-01

    Objective. To evaluate the performance of ultrasound in pediatric appendicitis and the integration of US with the pediatric appendicitis score (PAS) and C-reactive protein (CRP). Method. An institution-based, retrospective study of children who underwent abdominal US for suspected appendicitis between 2012 and 2015 at a tertiary pediatric surgery center. US results were dichotomized, with a nonvisualized appendix considered as a negative examination. Results. In total, 438 children were included (mean 8.5 years, 54% boys), with an appendicitis rate of 29%. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for US were 82%, 97%, 92%, and 93%, respectively, without significant age or gender differences. Pediatric radiologists had significantly higher sensitivity compared to general radiologists, 88% and 71%, respectively (p appendicitis, regardless of age or gender, and should be the first choice of imaging modalities. Combining US with PAS and CRP may reduce several unnecessary admissions for in-hospital observation. PMID:28044133

  2. Irregular or absent periods--what can an ultrasound scan tell you?

    Science.gov (United States)

    Khalid, Asma

    2004-02-01

    Transvaginal ultrasonography has increased our appreciation of the physiological changes in the ovary and endometrium that occur during the normal menstrual cycle. It has become a primary investigative tool in women with irregular or absent periods. Its usefulness in cases of primary amenorrhoea to assess anatomy is also undisputed although it may have limitations in terms of its specificity. However, the interpretation of ultrasound images in women with irregular menses or secondary amenorrhoea is not entirely straightforward. This is particularly true in the diagnosis of polycystic ovary syndrome, a condition of uncertain aetiology, which may present with oligoamenorrhoea. This chapter aims to discuss the benefits and limitations of ultrasound while taking into account the broad overlap between normal and abnormal physiology, some of which has still to be elucidated.

  3. Digital breast tomosynthesis versus mammography and breast ultrasound: a multireader performance study

    International Nuclear Information System (INIS)

    Thibault, Fabienne; Malhaire, Caroline; Tardivon, Anne; Dromain, Clarisse; Balleyguier, Corinne S.; Breucq, Catherine; Steyaert, Luc; Baldan, Enrica; Drevon, Harir

    2013-01-01

    To compare the diagnostic performance of single-view breast tomosynthesis (BT) with that of dual-view mammography (MX); to assess the benefit of adding the craniocaudal (CC) mammographic view to BT, and of adding BT to MX plus breast ultrasound, considered to be the reference work-up. One hundred and fifty-five consenting patients with unresolved mammographic and/or ultrasound findings or breast symptoms underwent conventional work-up plus mediolateral oblique-view BT of the affected breast. The final study set in 130 patients resulted in 55 malignant and 76 benign and normal cases. Seven breast radiologists rated the cases through five sequential techniques using a BIRADS-based scale: MX, MX + ultrasound, MX + ultrasound + BT, BT, BT + MX(CC). Multireader, multicase receiver operating characteristic (ROC) analysis was performed and performance of the techniques was assessed from the areas under ROC curves. The performance of BT and of BT + MX(CC) was tested versus MX; the performance of MX + ultrasound + BT tested versus MX + ultrasound. Tomosynthesis was found to be non-inferior to mammography. BT + MX(CC) did not appear to be superior to MX, and MX + ultrasound + BT not superior to MX + ultrasound. Overall, none of the five techniques tested outperformed the others. Further clinical studies are needed to clarify the role of BT as a substitute for traditional work-up in the diagnostic environment. (orig.)

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... scanning or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on ... to do the scanning. The transducer is a small hand-held device that resembles a microphone, attached ...

  5. Scanning Ultrasound (SUS Causes No Changes to Neuronal Excitability and Prevents Age-Related Reductions in Hippocampal CA1 Dendritic Structure in Wild-Type Mice.

    Directory of Open Access Journals (Sweden)

    Robert John Hatch

    Full Text Available Scanning ultrasound (SUS is a noninvasive approach that has recently been shown to ameliorate histopathological changes and restore memory functions in an Alzheimer's disease mouse model. Although no overt neuronal damage was reported, the short- and long-term effects of SUS on neuronal excitability and dendritic tree morphology had not been investigated. To address this, we performed patch-clamp recordings from hippocampal CA1 pyramidal neurons in wild-type mice 2 and 24 hours after a single SUS treatment, and one week and 3 months after six weekly SUS treatments, including sham treatments as controls. In both treatment regimes, no changes in CA1 neuronal excitability were observed in SUS-treated neurons when compared to sham-treated neurons at any time-point. For the multiple treatment groups, we also determined the dendritic morphology and spine densities of the neurons from which we had recorded. The apical trees of sham-treated neurons were reduced at the 3 month time-point when compared to one week; however, surprisingly, no longitudinal change was detected in the apical dendritic trees of SUS-treated neurons. In contrast, the length and complexity of the basal dendritic trees were not affected by SUS treatment at either time-point. The apical dendritic spine densities were reduced, independent of the treatment group, at 3 months compared to one week. Collectively, these data suggest that ultrasound can be employed to prevent an age-associated loss of dendritic structure without impairing neuronal excitability.

  6. CLINICOPATHOLOGICAL FACTORS ASSOCIATED WITH POSITIVE PREOPERATIVE AXILLARY ULTRASOUND SCANNING IN BREAST CANCER PATIENTS

    Directory of Open Access Journals (Sweden)

    Lona Jalini

    2016-01-01

    Full Text Available Background: Axillary lymph node status is the most important breast cancer prognostic factor. Preoperative axillary ultrasound examination (PAUS is used to triage patients for sentinel lymph node biopsy (SLNB or axillary lymph node dissection (ALND. We assessed the detection rate of lymph node metastases by PAUS in a screening unit and evaluated associations between clinicopathological factors and PAUS positivity. Patients and Methods: This was a single-centre retrospective analysis of data extracted from a hospital breast cancer database and clinical records. Clinical, radiological, and pathological and prognostic indices were compared between PAUS-positive and PAUS-negative patients subsequently found to have lymph node metastases on histopathological analysis. Results: Two hundred and two patients were eligible for analysis. 50.5% of lymph node-positive patients were correctly identified as PAUS positive. Patients with PAUS-positive lymph nodes had less favorable disease characteristics, namely clinically palpable lymph nodes, higher Nottingham prognostic (NPI index, high lymph node burden according to the European Society of Medical Oncology (ESMO group classification, and larger, grade 3 tumors with lymphovascular invasion and extranodal spread. Moreover, PAUS-positive patients had more macrometastases and lymph node involvement than PAUS-negative patients. Conclusion: PAUS-positive patients and PAUS-negative (SLNB-positive patients have different clinicopathological characteristics. The presence of LVI, extranodal spread, grade 3 histology, or large tumors with poor prognostic indices in PAUS-negative patients should be regarded with caution and perhaps prompt second-look ultrasound examination.

  7. Selective heating of soft tissue-bone interfaces during scanned focussed ultrasound hyperthermia

    International Nuclear Information System (INIS)

    Hynynen, K.; De Young, D.; Roemer, R.; Kundrat, M.

    1987-01-01

    Bone heating has been a frequent problem with clinical hyperthermia treatments induced by plane ultrasonic transducers. In this study, detailed temperature distributions were measured in dogs' (5 dogs) thigh muscles and bone in vivo while focussed ultrasound was applied to elevate the muscle temperature next to the bone. Significantly higher temperature elevations were measured at the bone surface than in the target volume in front of the bone. The temperature distribution was sharp decreasing fast inside the bone and also in front of it. By using more sharply focussed and multiple beams the temperature elevation at the bone surface was reduced and by suitable choice of the distance between the bone surface and the acoustical focus almost uniform temperature could be induced in the overlying muscle tissue from the surface down to the bone - the bone surface being in the same temperature as the muscle. Similar result was obtained by using single, higher frequency focussed beam (3.58 MHz). Also the utilization of nonlinear ultrasonic propagation appeared to reduce bone heating. The results showed that by carefully planning ultrasound hyperthermia treatments, tissues close to bone can be heated without extensive temperature elevation at bone surface

  8. SonoNet: Real-Time Detection and Localisation of Fetal Standard Scan Planes in Freehand Ultrasound.

    Science.gov (United States)

    Baumgartner, Christian F; Kamnitsas, Konstantinos; Matthew, Jacqueline; Fletcher, Tara P; Smith, Sandra; Koch, Lisa M; Kainz, Bernhard; Rueckert, Daniel

    2017-11-01

    Identifying and interpreting fetal standard scan planes during 2-D ultrasound mid-pregnancy examinations are highly complex tasks, which require years of training. Apart from guiding the probe to the correct location, it can be equally difficult for a non-expert to identify relevant structures within the image. Automatic image processing can provide tools to help experienced as well as inexperienced operators with these tasks. In this paper, we propose a novel method based on convolutional neural networks, which can automatically detect 13 fetal standard views in freehand 2-D ultrasound data as well as provide a localization of the fetal structures via a bounding box. An important contribution is that the network learns to localize the target anatomy using weak supervision based on image-level labels only. The network architecture is designed to operate in real-time while providing optimal output for the localization task. We present results for real-time annotation, retrospective frame retrieval from saved videos, and localization on a very large and challenging dataset consisting of images and video recordings of full clinical anomaly screenings. We found that the proposed method achieved an average F1-score of 0.798 in a realistic classification experiment modeling real-time detection, and obtained a 90.09% accuracy for retrospective frame retrieval. Moreover, an accuracy of 77.8% was achieved on the localization task.

  9. Accuracy of non-operative identification of the sentinel lymph node using combined gamma and ultrasound scanning

    International Nuclear Information System (INIS)

    Whelehan, P.; Vinnicombe, S.J.; Brown, D.C.; McLean, D.; Evans, A.

    2014-01-01

    Aim: To assess how accurately the sentinel lymph node (SLN) can be identified percutaneously, using gamma probe and ultrasound technology. Materials and methods: Women with breast cancer, scheduled for wide local excision or mastectomy with SLN biopsy (SLNB), were included. Peri-areolar intradermal injection of technetium-99 nanocolloid was performed on the morning of surgery and 1–2 ml of blue dye was injected in the peri-areolar region once the patient was anaesthetized. Prior to surgery, a gamma probe was used over the skin to identify any hot spot that could represent a SLN. Ultrasound, guided by the hot spot, was then used to visualize potential SLNs and guide the insertion of a localizing wire. The accuracy in localizing the SLN by preoperative gamma-probe guided ultrasonography was assessed by comparison to SLNB. Results: A SLN was correctly identified and marked using gamma-probe guided ultrasonography in 44 of 59 cases (75%; 95% CI: 63–86%). Conclusion: This study supports the case for investigating percutaneous gamma probe and ultrasound guided interventions in the axilla in women with breast cancer, as a potential alternative to surgical SLNB. - Highlights: • Percutaneous radio-isotope guided localisation of the SLN was successful in 75% of cases. • Success rates varied slightly by operator. • Success rates did not vary between same-day and previous-day isotope injection methods

  10. Accuracy of non-operative identification of the sentinel lymph node using combined gamma and ultrasound scanning.

    Science.gov (United States)

    Whelehan, P; Vinnicombe, S J; Brown, D C; McLean, D; Evans, A

    2014-08-01

    To assess how accurately the sentinel lymph node (SLN) can be identified percutaneously, using gamma probe and ultrasound technology. Women with breast cancer, scheduled for wide local excision or mastectomy with SLN biopsy (SLNB), were included. Peri-areolar intradermal injection of technetium-99 nanocolloid was performed on the morning of surgery and 1-2 ml of blue dye was injected in the peri-areolar region once the patient was anaesthetized. Prior to surgery, a gamma probe was used over the skin to identify any hot spot that could represent a SLN. Ultrasound, guided by the hot spot, was then used to visualize potential SLNs and guide the insertion of a localizing wire. The accuracy in localizing the SLN by preoperative gamma-probe guided ultrasonography was assessed by comparison to SLNB. A SLN was correctly identified and marked using gamma-probe guided ultrasonography in 44 of 59 cases (75%; 95% CI: 63-86%). This study supports the case for investigating percutaneous gamma probe and ultrasound guided interventions in the axilla in women with breast cancer, as a potential alternative to surgical SLNB. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  11. Efficacy and safety in performing of large bore percutaneous nephrostomy under ultrasound guidance

    International Nuclear Information System (INIS)

    Smilov, N.; Mlachkova, D.; Rizov, A.; Lozev, I.

    2009-01-01

    The aim of the study was to compare the success rate, complications and the outcomes from large-bore percutaneous nephrostomy under ultrasound guidance performed to 178 cases with another 54 when nephrostomy under x-ray control was performed. We have performed 178 large-bore percutaneous nephrostomy under ultrasound guidance and another 54 percutaneous nephrostomy under x-ray guidance to patients diagnosed with obstructive uropathy resulting from benign or malignant supravesical obstruction. We have performed successful nephrostomy in 93,8% of the cases under ultrasound guidance and 100% successful nephrostomy in the cases under x-ray control. In 2,8% of patients under ultrasound guidance the nephrostomy was performed using 4 additional punctures of the pyelocaliceal system and artificially caused hydronephrosis via infiltration of normal saline; and in the remaining 1,7% it was successful at the second attempt after 24 hours. It was not necessary to perform open surgery nephrostomy in any of the cases. The performance of percutaneous nephrostomy under ultrasound guidance has a success rate similar to the one done under x-ray guidance and with commensurable frequency and severity of complications, however without the patient and the operator being exposed to x-ray radiation. In general, the percutaneous nephrostomy under ultrasound guidance is performed without difficulties in the cases of third or fourth degree hydronephrosis. The lateral decubital patient position, the appropriate place for the puncture, the usage of Color Doppler imaging when the puncture is performed and the continuos ultrasound guidance during dilatation and placement of the nephrostomy tube should ensure the successful performance of the procedure in the case of first or second degree hydronephrosis. When hydronephrosis is absent, the nephrostomy should be performed under x-ray guidance. In emergency cases the application of ultrasound guidance allows the nephrostomy to be performed along the

  12. Obstetrical ultrasound

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    The use of diagnostic ultrasound in obstetrics may provide fuel for legal action. While most legal implications of this relatively new imaging modality are purely speculative, some have already given rise to legal action. Several situations will likely provide a basis for the courts to find against the physician. The failure to perform a sonogram when clinically indicated will most likely be the strongest plaintiff argument. Other major concerns include the use and availability of state-of-the-art equipment, as well as interpretation of the scans by a trained physician. Obstetrical ultrasound is usually performed by a radiologist or obstetrician. However, many physicians performing these examinations have had little or no formal training in the field. While this is now being remedied by the respective board examines who require a certain amount of training, it may not be enough. When ultrasound-related cases reach the courts, the involved physicians will most likely be regarded as experts in the field and, therefore, will be held to a very high standard of care. This would be difficult to achieve without formal training. At the present time, the American Board of Radiology requires more training time in ultrasound than the American Board of Obstetrics and Gynecology

  13. Focused ultrasound in ophthalmology

    Directory of Open Access Journals (Sweden)

    Silverman RH

    2016-09-01

    Full Text Available Ronald H Silverman1,2 1Department of Ophthalmology, Columbia University Medical Center, 2F.L. Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA Abstract: The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, mechanically scanned transducers are most common in ophthalmology. Specially designed transducers have been used to generate focused, high-intensity ultrasound that through thermal effects has been used to treat glaucoma (via cilio-destruction, tumors, and other pathologies. Linear and annular transducer arrays offer synthetic focusing in which precise timing of the excitation of independently addressable array elements allows formation of a converging wavefront to create a focus at one or more programmable depths. Most recently, linear array-based plane-wave ultrasound, in which the array emits an unfocused wavefront and focusing is performed solely on received data, has been demonstrated for imaging ocular anatomy and blood flow. While the history of ophthalmic ultrasound extends back over half-a-century, new and powerful technologic advances continue to be made, offering the prospect of novel diagnostic capabilities. Keywords: ophthalmic ultrasound, ultrasound biomicroscopy (UBM, high-intensity focused ultrasound (HIFU, ultrafast imaging, Doppler imaging 

  14. The skin-to-calyx distance measured by renal ct scan and ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Shan, Chen Jen; Mazzucchi, Eduardo; Payão, Fabio; Gomes, Andrea Cavalanti; Baroni, Ronaldo Hueb; Torricelli, Fabio Cesar; Vicentini, Fabio Carvalho; Srougi, Miguel [Hospital das Clínicas, University of Sao Paulo Medical School, Sao Paulo, SP (Brazil)

    2014-03-15

    Purpose: We developed a stereotactic device to guide the puncture for percutaneous nephrolithotripsy, which uses the distance from the target calyx to its perpendicular point on skin (SCD) to calculate the needle´s entry angle. This study seeks to validate the use of measurements obtained by ultrasound (US) and computerized tomography (CT) for needle´s entry angle calculation and to study factors that may interfere in this procedure. Materials and Methods: Height, weight, abdominal circumference, CT of the urinary tract in dorsal decubitus (DD) and ventral decubitus (VD), and US of the kidneys in VD were obtained from thirty-five renal calculi patients. SCD obtained were compared and correlated with body-mass index (BMI). Results: BMI was 28.66 ± 4.6 Kg/m2. SCD on CT in DD was 8.40 ± 2.06cm, in VD was 8.32 ± 1.95cm, in US was 6.74 ± 1.68cm. SCD measured by US and CT were statistically different (p < 0.001), whereas between CT in DD and VD were not. SCD of the lower calyx presented moderate correlation with BMI. Conclusion: SCD obtained by CT in ventral and dorsal decubitus may be used for calculation of the needle´s entry angle. SCD obtained by US cannot be used. A rule for the correlation between BMI and the SCD could not be determined. (author)

  15. Proactive error analysis of ultrasound-guided axillary brachial plexus block performance.

    LENUS (Irish Health Repository)

    O'Sullivan, Owen

    2012-07-13

    Detailed description of the tasks anesthetists undertake during the performance of a complex procedure, such as ultrasound-guided peripheral nerve blockade, allows elements that are vulnerable to human error to be identified. We have applied 3 task analysis tools to one such procedure, namely, ultrasound-guided axillary brachial plexus blockade, with the intention that the results may form a basis to enhance training and performance of the procedure.

  16. Effects of Student-Performed Point-of-Care Ultrasound on Physician Diagnosis and Management of Patients in the Emergency Department.

    Science.gov (United States)

    Udrea, Daniel S; Sumnicht, Andrew; Lo, Deanna; Villarreal, Logan; Gondra, Stephanie; Chyan, Richard; Wisham, Audra; Dinh, Vi Am

    2017-07-01

    Despite the increasing integration of ultrasound training into medical education, there is an inadequate body of research demonstrating the benefits and practicality of medical student-performed point-of-care ultrasound (SP-POCUS) in the clinical setting. The primary purpose of this study was to evaluate the effects that SP-POCUS can have on physician diagnosis and management of patients in the emergency department, with a secondary purpose of evaluating the diagnostic accuracy of SP-POCUS. SP-POCUS examinations were performed in the emergency department by medical students who completed year one of a 4-year medical school curriculum with integrated ultrasound training. Scans were evaluated by an emergency physician who then completed a survey to record any changes in diagnosis and management. A total of 641 scans were performed on the 482 patients enrolled in this study. SP-POCUS resulted in a change in management in 17.3% of scans performed. For 12.4% of scans, SP-POCUS discovered a new diagnosis. SP-POCUS reduced time to disposition 33.5% of the time. Because of SP-POCUS, physicians avoided ordering an additional imaging study for 53.0% of the scans performed. There was 94.7% physician agreement with SP-POCUS diagnosis. This study showed that SP-POCUS is feasible and may potentially have a meaningful impact on physician diagnosis and management of patients in the emergency department. In addition, the implementation of SP-POCUS could serve as an ideal method of developing ultrasound skills in medical school while positively impacting patient care. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the procedure? In women, a pelvic ultrasound is most often performed to evaluate the: uterus cervix ovaries ... page How is the procedure performed? Transabdominal: For most ultrasound exams, you will be positioned lying face- ...

  18. Ultrasound screening of thyroid nodules in adults with no previous exposed to irradiation comparison between scanning, palpation and fine needle aspiration cytology. A study in Ghaem Hospital, Mashhad, North East of Iran

    International Nuclear Information System (INIS)

    Rahrouh, M.; Namadanian, G.R.; Zakavi, S.R.; Rezaei, H.

    2003-01-01

    There are a great number of studies on the association between childhood radiation exposure and thyroid nodules and cancer. Ultrasound imaging of thyroid nodules is valuable part of diagnostics and identifies abnormalities, because ultrasound can detect nodules as small as 2-3 mm and no radiation is involved , it has gained wide acceptance for the screening of nodular thyroid disease. 500 subjects were selected randomly from medical students in university of medical sciences in Mashhad North East of Iran. Individuals were screened by a health survey , thyroid ultrasounds, 99mTc-pertechnetate scans, palpation and fine needle aspiration obtained as necessary. The ultrasound was performed with a 7.5-MHz transducer in direct contact with the lubricated skin of the extended neck. Each ultrasound exam was read independently by two radiologists and one endocrinologist. Each nodule was characterized as follows: 1) presence; 2) size ; 3) location; ant or post; 4) location; upper pole, midportion of lobe, lower pole, or isthmus; and 5) type; solid, cystic, or mixed. In 500 cases (312 men, 188 women; age range, 18 - 30 years) underwent neck sonography. Normal findings were verified by clinical follow-up and thyroid disease was found in (5%) of subjectes. A total of 25 certain thyroid nodules were detected by the ultrasound examinations. Eighty eight percent nodules were less than 1.0 cm dimension.Among the subjects who had them thyroid nodules,(48%) were cystic , (44%) were hypoechoic lesions and (8 %) were hyperechoic .The abnormality of thyroid echo was solitary in (1,8%) ,multiple in (1,4%) and diffuse in (0,6%) of subjectes. All abnormal findings were verified by fine needle aspiration biopsy and correlated with thyroid scan, and surgery. The results reported here can be compared to several reports on the prevalence of ultrasound detected thyroid nodules in adult populations not exposed to radiation .The major advantage is that ultrasound can find clinically important

  19. Ovarian and uterine maturity assessed by pelvic ultrasound scanning in adolescent girls with anorexia nervosa at the start of treatment – correlation with the history of menstruation

    Directory of Open Access Journals (Sweden)

    Gabriela Jagielska

    2010-12-01

    Full Text Available In females, absence of at least three consecutive menstrual cycles when otherwise expected to occur or cessation of pubescence (primary and secondary amenorrhea are the symptoms of anorexia nervosa, secondary to hypogonadotropic hypogonadism. Disturbances in sexual organs are seen in inappropriate for age pelvic ultrasound scanning. The aim of the study was to determine the ovarian and uterine maturity at the onset of anorexia nervosa (AN in adolescence, using pelvic ultrasound scanning, and their relations to clinical factors describing the course of AN. Material and method: The group consisted of 38 adolescent girls with anorexia nervosa diagnosed acc. to ICD-10 criteria – mean age 14.3±2.1 years, mean age at the beginning of AN symptoms 13±2.3 years, mean BMI 14±1.6 kg/m2. On initial assessment, all girls underwent physical examination, clinical interview concerning AN symptoms and pelvic ultrasound scanning. Results: Sixteen patients (42% had primary amenorrhea. In 32% of patients cessation of menses occurred before a significant decrease in weight. Ovarian and uterine volumes significantly below the expected were found in 11 and 15 patients with secondary amenorrhea, respectively. The varian and uterine maturity was related to shorter duration of amenorrhea and longer duration of adequate menstruation before the onset of AN. There were no BMI differences between the groups with more and less mature ultrasound picture.

  20. Principle and performance of the transverse oscillation vector velocity technique in medical ultrasound

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Pihl, Michael Johannes; Udesen, Jesper

    2010-01-01

    Medical ultrasound systems measure the blood velocity by tracking the blood cells motion along the ultrasound field. The is done by pulsing in the same direction a number of times and then find e.q. the shift in phase between consecutive pulses. Properly normalized this is directly proportional...... a double oscillating field. A special estimator is then used for finding both the axial and lateral velocity component, so that both magnitude and phase can be calculated. The method for generating double oscillating ultrasound fields and the special estimator are described and its performance revealed...

  1. Performance of analytical methods for tomographic gamma scanning

    International Nuclear Information System (INIS)

    Prettyman, T.H.; Mercer, D.J.

    1997-01-01

    The use of gamma-ray computerized tomography for nondestructive assay of radioactive materials has led to the development of specialized analytical methods. Over the past few years, Los Alamos has developed and implemented a computer code, called ARC-TGS, for the analysis of data obtained by tomographic gamma scanning (TGS). ARC-TGS reduces TGS transmission and emission tomographic data, providing the user with images of the sample contents, the activity or mass of selected radionuclides, and an estimate of the uncertainty in the measured quantities. The results provided by ARC-TGS can be corrected for self-attenuation when the isotope of interest emits more than one gamma-ray. In addition, ARC-TGS provides information needed to estimate TGS quantification limits and to estimate the scan time needed to screen for small amounts of radioactivity. In this report, an overview of the analytical methods used by ARC-TGS is presented along with an assessment of the performance of these methods for TGS

  2. Inter-Scan Reproducibility of Carotid Plaque Volume Measurements by 3-D Ultrasound

    DEFF Research Database (Denmark)

    Sandholt, Benjamin V; Collet-Billon, Antoine; Entrekin, Robert

    2018-01-01

    (PPV) measure centered on MPT. Total plaque volume (TPV), PPV from a 10-mm segment and MPT were measured using dedicated semi-automated software on 38 plaques from 26 patients. Inter-scan reproducibility was assessed using the t-test, Bland-Altman plots and Pearson's correlation coefficient....... There was a mean difference of 0.01 mm in MPT (limits of agreement: -0.45 to 0.42 mm, Pearson's correlation coefficient: 0.96). Both volume measurements exhibited high reproducibility, with PPV being superior (limits of agreement: -35.3 mm3to 33.5 mm3, Pearson's correlation coefficient: 0.96) to TPV (limits...... of agreement: -88.2 to 61.5 mm3, Pearson's correlation coefficient: 0.91). The good reproducibility revealed by the present results encourages future studies on establishing plaque quantification as part of cardiovascular risk assessment and for follow-up of disease progression over time....

  3. 2-D Ultrasound Scanning Probes for 3-D Medical Diagnostic Imaging

    National Research Council Canada - National Science Library

    Slayton, Michael

    1999-01-01

    .... It is being pursued vigorously by the industry and is technologically feasible. However, cost versus performance issues are currently extremely sensitive and holding back commercialization of a number of 3-D technical concepts...

  4. Use of modulated excitation signals in ultrasound. Part II: Design and performance for medical imaging applications

    DEFF Research Database (Denmark)

    Misaridis, Thanassis; Jensen, Jørgen Arendt

    2005-01-01

    ultrasound presents design methods of linear FM signals and mismatched filters, in order to meet the higher demands on resolution in ultrasound imaging. It is shown that for the small time-bandwidth (TB) products available in ultrasound, the rectangular spectrum approximation is not valid, which reduces....... The method is evaluated first for resolution performance and axial sidelobes through simulations with the program Field II. A coded excitation ultrasound imaging system based on a commercial scanner and a 4 MHz probe driven by coded sequences is presented and used for the clinical evaluation of the coded...... excitation/compression scheme. The clinical images show a significant improvement in penetration depth and contrast, while they preserve both axial and lateral resolution. At the maximum acquisition depth of 15 cm, there is an improvement of more than 10 dB in the signal-to-noise ratio of the images...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls ...

  6. Can continuous scans in orthogonal planes improve diagnostic performance of shear wave elastography for breast lesions?

    Science.gov (United States)

    Yang, Pan; Peng, Yulan; Zhao, Haina; Luo, Honghao; Jin, Ya; He, Yushuang

    2015-01-01

    Static shear wave elastography (SWE) is used to detect breast lesions, but slice and plane selections result in discrepancies. To evaluate the intraobserver reproducibility of continuous SWE, and whether quantitative elasticities in orthogonal planes perform better in the differential diagnosis of breast lesions. One hundred and twenty-two breast lesions scheduled for ultrasound-guided biopsy were recruited. Continuous SWE scans were conducted in orthogonal planes separately. Quantitative elasticities and histopathology results were collected. Reproducibility in the same plane and diagnostic performance in different planes were evaluated. The maximum and mean elasticities of the hardest portion, and standard deviation of whole lesion, had high inter-class correlation coefficients (0.87 to 0.95) and large areas under receiver operation characteristic curve (0.887 to 0.899). Without loss of accuracy, sensitivities had increased in orthogonal planes compared with single plane (from 73.17% up to 82.93% at most). Mean elasticity of whole lesion and lesion-to-parenchyma ratio were significantly less reproducible and less accurate. Continuous SWE is highly reproducible for the same observer. The maximum and mean elasticities of the hardest portion and standard deviation of whole lesion are most reliable. Furthermore, the sensitivities of the three parameters are improved in orthogonal planes without loss of accuracies.

  7. The role of contrast-enhanced ultrasound (CEUS) in visualizing atherosclerotic carotid plaque vulnerability: Which injection protocol? Which scanning technique?

    Energy Technology Data Exchange (ETDEWEB)

    Iezzi, Roberto, E-mail: roberto.iezzi@rm.unicatt.it [Department of Bioimaging and Radiological Sciences, Institute of Radiology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Petrone, Gianluigi [Institute of Pathology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168, Rome (Italy); Ferrante, Angela [Department of Vascular Surgery, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Lauriola, Libero [Institute of Pathology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168, Rome (Italy); Vincenzoni, Claudio [Department of Vascular Surgery, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Torre, Michele Fabio la [Department of Bioimaging and Radiological Sciences, Institute of Radiology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Snider, Francesco [Department of Vascular Surgery, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy); Rindi, Guido [Institute of Pathology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168, Rome (Italy); Bonomo, Lorenzo [Department of Bioimaging and Radiological Sciences, Institute of Radiology, “A. Gemelli” Hospital—Catholic University, L.go A Gemelli 8, 00168 Rome (Italy)

    2015-05-15

    Highlights: • CEUS is a safe and efficacious technique for the identification and characterization of carotid plaque. • CEUS represents a diagnostic tool for the management of patients with carotid plaque, particularly in asymptomatic patients. • Improved diagnostic performance is achieved with the injection of 4 mL bolus of contrast-medium. • Improved diagnostic performance is achieved with the use of Dynamic Imaging rather than late-phase imaging. - Abstract: Purpose: To correlate the degree of plaque vulnerability as determined by contrast-enhanced ultrasound (CEUS) with histological findings. Secondary objectives were to optimize the CEUS acquisition technique and image evaluation methods. Materials and methods: Fifty consecutive patients, either symptomatic and asymptomatic referring to our department in order to perform carotid endarterectomy (TEA), were enrolled. Each patient provided informed consent before undergoing CEUS. Ultrasound examination was performed using high-frequency (8–14 MHz) linear probe and a non-linear pulse inversion technique (mechanical index: 0.09–1.3). A double contrast media injection (Sonovue, 2 mL and 4 mL; Bracco, Italy) was performed. Two videotapes were recorded for every injection: early “dynamic” phase and late “flash” phase, performed with 6 high mechanical index impulses. Movies were quantitatively and qualitatively evaluated. Qualitative and quantitative evaluation were statistically compared to immunohistological diagnosis of vulnerable plaque, considered as gold standard. Results: Qualitative CEUS evaluation obtained high statistical results when compared to immunohistological results, with values of sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of 94%, 68%, 87%, 85% and 86%, respectively, which became higher if considering only asymptomatic patient, with a NPV of 91%. Nevertheless, quantitative software evaluation proved less

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not use any ionizing radiation. Ultrasound scanning gives a clear picture of soft tissues that do not show up well on ...

  9. Performance evaluation of a vibration desensitized scanning white light interferometer

    International Nuclear Information System (INIS)

    Troutman, J; Evans, C J; Ganguly, V; Schmitz, T L

    2014-01-01

    Surface metrology instruments normally require thermal, seismic and acoustic isolation. Shop-floor metrology solutions offer reduced cost and process time. If they operate on the same principles as laboratory devices, an inherent sensitivity to vibration remains. This paper describes a methodology for evaluating ‘environmental tolerance’ and applying it to characterize a recently introduced ‘environmentally tolerant’ scanning white light interferometer (SWLI). Previously published measurements of replicated nickel reference standards on the new instrument and on a stylus profilometer showed good correlation. Surface topography repeatabilities (per ISO 25178-604:2013) were insignificantly different when evaluated on the SWLI instrument in a metrology laboratory and in a manufacturing area. Measurements of reference standards under forced vibration of the entire instrument show maximum ripple error and data dropout in regions of structural resonance. Measurements were performed with large forced horizontal and vertical sample oscillation beneath the objective, exhibiting maximum ripple error near odd integer multiples of half the instrument detector frequency. Error due to data dropout was also investigated. (paper)

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... no ionizing radiation. Ultrasound scanning may be able to give a clearer picture of soft tissues that do ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... scanning or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on ... the child prior to the exam. Bringing books, small toys, music or games can help to distract ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  13. Ultrasound pregnancy

    Science.gov (United States)

    Pregnancy sonogram; Obstetric ultrasonography; Obstetric sonogram; Ultrasound - pregnancy; IUGR - ultrasound; Intrauterine growth - ultrasound; Polyhydramnios - ultrasound; Oligohydramnios - ultrasound; ...

  14. Relationship between hemodynamic changes of portal vein and hepatic artery measured by color Doppler ultrasound and FibroScan value in patients with liver cirrhosis

    Directory of Open Access Journals (Sweden)

    CHENG Xiaofei

    2014-11-01

    Full Text Available ObjectiveTo explore the relationship between hemodynamic changes of the portal vein and hepatic artery measured by color Doppler ultrasound and FibroScan value in patients with liver cirrhosis. MethodsA total of 192 patients with hepatitis B cirrhosis who were admitted to our hospital from March 2010 to December 2013, as well as 100 healthy persons, were recruited. The mean portal vein blood flow velocity (PVVmean, hepatic artery pulsatility index (HAPI, and hepatic artery resistance index (HARI were measured by color Doppler ultrasound. FibroScan was also carried out. All data were statistically analyzed using SPSS 13.0. Continuous data were expressed as mean±SD and compared between groups by t-test. ResultsThe HAPI, HARI, and FibroScan value of the patient group were 1.56±024, 0.73±0.05, and 25.38±7.73, respectively, significantly higher than those of the control group (1.36±0.14, 0.65±0.07, and 7.8±3.6 (P<0.05; the PVVmean of the patient group was 14.43±1.86, significantly lower than that of the control group (17.35±0.56 (P<0.05. FibroScan value was positively correlated with HAPI and HARI (r1=0.59, r2=0.66, P<0.001, but negatively correlated with PVVmean (r=-0.64, P<0.001. ConclusionThe liver stiffness assessed by FibroScan and the hemodynamic changes of the portal vein and hepatic artery measured by color Doppler ultrasound are vitally important for evaluating the severity of liver cirrhosis.

  15. Derivation of a Performance Checklist for Ultrasound-Guided Arthrocentesis Using the Modified Delphi Method.

    Science.gov (United States)

    Kunz, Derek; Pariyadath, Manoj; Wittler, Mary; Askew, Kim; Manthey, David; Hartman, Nicholas

    2017-06-01

    Arthrocentesis is an important skill for physicians in multiple specialties. Recent studies indicate a superior safety and performance profile for this procedure using ultrasound guidance for needle placement, and improving quality of care requires a valid measurement of competency using this modality. We endeavored to create a validated tool to assess the performance of this procedure using the modified Delphi technique and experts in multiple disciplines across the United States. We derived a 22-item checklist designed to assess competency for the completion of ultrasound-guided arthrocentesis, which demonstrated a Cronbach's alpha of 0.89, indicating an excellent degree of internal consistency. Although we were able to demonstrate content validity for this tool, further validity evidence should be acquired after the tool is used and studied in clinical and simulated contexts. © 2017 by the American Institute of Ultrasound in Medicine.

  16. Transmitting Performance Evaluation of ASICs for CMUT-Based Portable Ultrasound Scanners

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Diederichsen, Søren Elmin; Jørgensen, Ivan Harald Holger

    2017-01-01

    Portable ultrasound scanners (PUS) have, in recent years, raised a lot of attention, as they can potentially overcome some of the limitations of static scanners. However, PUS have a lot of design limitations including size and power consumption. These restrictions can compromise the image quality...... of the scanner. In order to overcome these restrictions, application specific integrated circuits (ASICs) are needed to implement the electronics. In this work, a comparative study of the transmitting performance of a capacitive micromachined ultrasonic transducer (CMUT) driven by a commercial generic ultrasound...

  17. Training Midwives to Perform Basic Obstetric Point-of-Care Ultrasound in Rural Areas Using a Tablet Platform and Mobile Phone Transmission Technology-A WFUMB COE Project.

    Science.gov (United States)

    Vinayak, Sudhir; Sande, Joyce; Nisenbaum, Harvey; Nolsøe, Christian Pállson

    2017-10-01

    Point-of-care ultrasound (POCUS) has become a topical subject and can be applied in a variety of ways with differing outcomes. The cost of all diagnostic procedures including obstetric ultrasound examinations is a major factor in the developing world and POCUS is only useful if it can be equated to good outcomes at a lower cost than a routine obstetric examination. The aim of this study was to assess a number of processes including accuracy of images and reports generated by midwives, performance of a tablet-sized ultrasound scanner, training of midwives to complete ultrasounds, teleradiology solution transmissions of images via internet, review of images by a radiologist, communication between midwife and radiologist, use of this technique to identify high-risk patients and improvement of the education and teleradiology model components. The midwives had no previous experience in ultrasound. They were stationed in rural locations where POCUS was available for the first time. After scanning the patients, an interim report was generated by the midwives and sent electronically together with all images to the main hospital for validation. Unique software was used to send lossless images by mobile phone using a modem. Transmission times were short and quality of images transmitted was excellent. All reports were validated by two experienced radiologists in our department and returned to the centers using the same transmission software. The transmission times, quality of scans, quality of reports and other parameters were recorded and monitored. Analysis showed excellent correlation between provisional and validated reports. Reporting accuracy of scans performed by the midwives was 99.63%. Overall flow turnaround time (from patient presentation to validated report) was initially 35 min but reduced to 25 min. The unique mobile phone transmission was faultless and there was no degradation of image quality. We found excellent correlation between final outcomes of the

  18. Round Robin Test for Performance Demonstration System of Ultrasound Examination Personnel in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kim, Young Ho; Yang, Seung Han; Kim, Yong Sik; Yoon, Byung Sik; Lee, Hee Jong

    2005-01-01

    Ultrasound testing performance during in-service inspection for the main components of NPPs is strongly affected by each examination person. Therefore, ASME established a more strict qualification requirement in Sec. XI Appendix VIII for the ultrasound testing personnel in nuclear power plants. The Korean Performance Demonstration (KPD) System according to the ASME code for the ultrasonic testing personnel, equipments, and procedures to apply to the Class 1 and 2 piping ultrasound examination of nuclear power plants in Korea was established. And a round robin test was conducted in order to verify the effectiveness of PD method by comparing the examination results from the method of Performance Demonstration (PD) and a traditional ASME code dB-drop method. The round robin test shows that the reliability of the PD method is better than that of the dB-drop method. As a result, application of the PD method to the in-service inspection of the nuclear power plants will improve the performance of ultrasound testing

  19. Performance of Ultrasound in the Diagnosis of Gout in a Multi-Center Study

    DEFF Research Database (Denmark)

    Ogdie, Alexis; Taylor, William J; Neogi, Tuhina

    2017-01-01

    OBJECTIVES: To examine the performance of ultrasound for the diagnosis of gout using presence of monosodium urate (MSU) crystals as the gold standard. METHODS: We analyzed data from the Study for Updated Gout Classification Criteria (SUGAR), a large, multi-center observational cross-sectional stu...

  20. Diagnostic performance and useful findings of ultrasound re-evaluation for patients with equivocal CT features of acute appendicitis.

    Science.gov (United States)

    Kim, Mi Sung; Kwon, Heon-Ju; Kang, Kyung A; Do, In-Gu; Park, Hee-Jin; Kim, Eun Young; Hong, Hyun Pyo; Choi, Yoon Jung; Kim, Young Hwan

    2018-02-01

    To evaluate the diagnostic performance of ultrasound and to determine which ultrasound findings are useful to differentiate appendicitis from non-appendicitis in patients who underwent ultrasound re-evaluation owing to equivocal CT features of acute appendicitis. 62 patients who underwent CT examinations for suspected appendicitis followed by ultrasound re-evaluation owing to equivocal CT findings were included. Equivocal CT findings were considered based on the presence of only one or two findings among the CT criteria, and ultrasound re-evaluation was done based on a predefined structured report form. The diagnostic performance of ultrasound and independent variables to discriminate appendicitis from non-appendicitis were assessed. There were 27 patients in the appendicitis group. The overall diagnostic performance of ultrasound re-evaluation was sensitivity of 96.3%, specificity of 91.2% and accuracy of 91.9%. In terms of the performance of individual ultrasound findings, probe-induced tenderness showed the highest accuracy (86.7%) with sensitivity of 74% and specificity of 97%, followed by non-compressibility (accuracy 71.7%, sensitivity 85.2% and specificity 60.6%). The independent ultrasound findings for discriminating appendicitis were non-compressibility (p = 0.002) and increased flow on the appendiceal wall (p = 0.001). Ultrasound re-evaluation can be used to improve diagnostic accuracy in cases with equivocal CT features for diagnosing appendicitis. The presence of non-compressibility and increased vascular flow on the appendix wall are useful ultrasound findings to discriminate appendicitis from non-appendicitis. Advances in knowledge: Ultrasound re-evaluation is useful to discriminate appendicitis from non-appendicitis when CT features are inconclusive.

  1. Identifying subassemblies by ultrasound to prevent fuel handling error in sodium fast reactors: First test performed in water

    International Nuclear Information System (INIS)

    Paumel, Kevin; Lhuillier, Christian

    2015-01-01

    Identifying subassemblies by ultrasound is a method that is being considered to prevent handling errors in sodium fast reactors. It is based on the reading of a code (aligned notches) engraved on the subassembly head by an emitting/receiving ultrasonic sensor. This reading is carried out in sodium with high temperature transducers. The resulting one-dimensional C-scan can be likened to a binary code expressing the subassembly type and number. The first test performed in water investigated two parameters: width and depth of the notches. The code remained legible for notches as thin as 1.6 mm wide. The impact of the depth seems minor in the range under investigation. (authors)

  2. Assessment of breadmaking performance of wheat flour dough by means of frequency dependent ultrasound

    International Nuclear Information System (INIS)

    Braunstein, D; Peressini, D; Page, J H; Strybulevych, A; Scanlon, M G

    2012-01-01

    Technological performance of wheat flour varies among different wheat varieties. Gluten plays a key role within the solid phase of dough in the formation and the retention of gas bubbles during breadmaking. Rheological tests are usually performed to predict breadmaking potential. The aim here was to investigate the ability of ultrasound to discriminate wheat doughs based on breadmaking qualities. The ultimate goal is the development of an online quality control system currently unavailable in the baked goods industry, rendering this work innovative. Samples were prepared from a strong wheat flour, with one control sample and one added with inulin and distilled monoglycerides, producing doughs of distinct breadmaking quality. Doughs were subjected to density determination, elongation tests, and ultrasound analysis. The ultrasound tests were performed in the frequency range of 300 kHz – 6 MHz. Ultrasonic phase velocity increased with increasing frequency to about 2 MHz, becoming constant and then decreasing from 3 MHz for the control sample. Distinct differences in attenuation coefficient between the fibre-enriched and control doughs were observed. Ultrasound can potentially add to a better understanding of dough quality and can discriminate between doughs of contrasting properties.

  3. Assessment of breadmaking performance of wheat flour dough by means of frequency dependent ultrasound

    Science.gov (United States)

    Braunstein, D.; Page, J. H.; Strybulevych, A.; Peressini, D.; Scanlon, M. G.

    2012-12-01

    Technological performance of wheat flour varies among different wheat varieties. Gluten plays a key role within the solid phase of dough in the formation and the retention of gas bubbles during breadmaking. Rheological tests are usually performed to predict breadmaking potential. The aim here was to investigate the ability of ultrasound to discriminate wheat doughs based on breadmaking qualities. The ultimate goal is the development of an online quality control system currently unavailable in the baked goods industry, rendering this work innovative. Samples were prepared from a strong wheat flour, with one control sample and one added with inulin and distilled monoglycerides, producing doughs of distinct breadmaking quality. Doughs were subjected to density determination, elongation tests, and ultrasound analysis. The ultrasound tests were performed in the frequency range of 300 kHz - 6 MHz. Ultrasonic phase velocity increased with increasing frequency to about 2 MHz, becoming constant and then decreasing from 3 MHz for the control sample. Distinct differences in attenuation coefficient between the fibre-enriched and control doughs were observed. Ultrasound can potentially add to a better understanding of dough quality and can discriminate between doughs of contrasting properties.

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... 3-D) ultrasound that formats the sound wave data into 3-D images. A Doppler ultrasound study ... to do the scanning. The transducer is a small hand-held device that resembles a microphone, attached ...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Most ultrasound scanning is noninvasive (no needles ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  6. Effects of introducing routinely ultrasound scanning during Ante Natal Care (ANC) clinics on number of visits of ANC and facility delivery: a cohort study.

    Science.gov (United States)

    Mbuyita, Selemani; Tillya, Robert; Godfrey, Ritha; Kinyonge, Iddajovana; Shaban, Josephine; Mbaruku, Godfrey

    2015-01-01

    Many countries have integrated antenatal care as an essential part of routine maternal health services. The importance of this service cannot be overemphasized as many women's lives are usually saved particularly through early detection of pregnancy related complications. However, while many women would attend at least one visit for ante natal care (ANC), completion of recommended number of visits (4+) has been a challenge of many health systems particularly in developing countries like Tanzania. We conducted a cohort study to include ultrasound scanning using a portable hand-held Vscan to test whether by integrating it in routine ANC clinics at dispensary and health centre levels would promote number of ANC visits by women. Health providers rendering ANC services in selected facilities were trained on how to use the simple technology of ultrasound scanning. Women living in catchment areas of the respective selected facilities were eligible to inclusion to the study when consented. A baseline status of the ANC attendance in the study area was established through baseline household and facility surveys. A total of 257 women consented and received the study treatment. Our results showed that, there was no a slight change between baseline (97.2 %) and endline (97.4 %) results among women attending ANC clinics at least once. However, there was a significant change in percentage of women attending ANC clinic four times or more (27.2 % during baseline and 60.3 %; p = 0001). We conclude that, introduction of the simplified ultrasound scanning technology at lowest levels of care has an effect to improving ANC attendance in terms of number of visits and motivate facility delivery.

  7. [Could we perform quality second trimester ultrasound among obese pregnant women?].

    Science.gov (United States)

    Fuchs, F; Voulgaropoulos, A; Houllier, M; Senat, M-V

    2013-05-01

    To compare the quality of second trimester ultrasound images and their anatomical quality scores among obese women and those with a normal body mass index (BMI). This prospective study, which took place from 2009 to 2011, included every obese pregnant woman (prepregnancy BMI greater than 30 kg/m(2)) who had an ultrasound examination at 20 to 24 weeks in our hospital and a control group with a normal BMI (20-24.9kg/m(2)) who had the same examination. A single operator evaluated the quality of all images, reviewing the standardized ultrasound planes - three biometric and six anatomical - required by French guidelines and scoring the quality of the six anatomical images. Each image was assessed according to 4-6 criteria, each worth one point. We sought excellent quality, defined as the frequency of maximum points for a given image. The obese group included 223 women and the control group 60. The completion rate for each image was at least 95 % in the control group and 90 % in the obese group, except for diaphragm and right outflow tract images. Overall, the excellence rate varied from 35 % to 92 % in the normal BMI group and 18 % to 58 % in the obese group and was significantly lower in the latter for all images except abdominal circumference (P=0.26) and the spine (P=0.06). Anatomical quality scores were also significantly lower in the obese group (22.3 vs. 27.2 ; P=0.001). Image quality and global anatomical scores in second trimester ultrasound scans were significantly lower among obese than normal-weight women. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  8. Initial experience of automated breast volume scanning (ABVS) and ultrasound elastography in predicting breast cancer subtypes and staging.

    Science.gov (United States)

    Wang, Xiao-Lei; Tao, Lin; Zhou, Xian-Li; Wei, Hong; Sun, Jia-Wei

    2016-12-01

    Breast cancer is a heterogeneous disease consisting of distinct histopathological subtypes with different clinical outcomes. In this article, we identified the automated breast volume scanning (ABVS) and shear wave velocity (SWV) characteristics of different pathological types of breast carcinoma. A retrospective review of both ABVS and SWV imaging of 118 consecutive breast masses was performed. The imaging features of both techniques were assessed with reference to histopathological results. Echo heterogeneity with a smooth and lobulated margin was a significant feature more frequently found in mucinous carcinoma groups (100%, P breast carcinoma stages. The central and tumor margin areas of ductal carcinomas were much harder than in tubular carcinoma and micro-carcinoma, respectively (P breast carcinoma types and stages, ABVS and SWV imaging has the potential to give clues about breast carcinoma differentiation in a non-invasive manner. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. [Ultrasound findings in rhabdomyolysis].

    Science.gov (United States)

    Carrillo-Esper, Raúl; Galván-Talamantes, Yazmin; Meza-Ayala, Cynthia Margarita; Cruz-Santana, Julio Alberto; Bonilla-Reséndiz, Luis Ignacio

    Rhabdomyolysis is defined as skeletal muscle necrosis. Ultrasound assessment has recently become a useful tool for the diagnosis and monitoring of muscle diseases, including rhabdomyolysis. A case is presented on the ultrasound findings in a patient with rhabdomyolysis. To highlight the importance of ultrasound as an essential part in the diagnosis in rhabdomyolysis, to describe the ultrasound findings, and review the literature. A 30 year-old with post-traumatic rhabdomyolysis of both thighs. Ultrasound was performed using a Philips Sparq model with a high-frequency linear transducer (5-10MHz), in low-dimensional scanning mode (2D), in longitudinal and transverse sections at the level of both thighs. The images obtained showed disorganisation of the orientation of the muscle fibres, ground glass image, thickening of the muscular fascia, and the presence of anechoic areas. Ultrasound is a useful tool in the evaluation of rhabdomyolysis. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  10. Anicteric dilatation of the biliary tree demonstrated by ultrasound 131I rose bengal liver scan and PTC

    International Nuclear Information System (INIS)

    Kapoor, R.; Saha, M.M.; Gupta, A.K.

    1991-01-01

    An uncommon case of gross dilatation of biliary tract, without clinical or biochemical evidence of jaundice, is presented. Dilatation of bile ducts was initially demonstrated on ultrasound and it was subsequently confirmed by 131 I rose bengal liver can, PTC and at surgery. (author). 6 refs., 3 figs

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of page How is the procedure performed? For most ultrasound exams, you will be positioned lying face- ... Ultrasound examinations are painless and easily tolerated by most patients. Ultrasound exams in which the transducer is ...

  12. Ultrasound guided supraclavicular block.

    LENUS (Irish Health Repository)

    Hanumanthaiah, Deepak

    2013-09-01

    Ultrasound guided regional anaesthesia is becoming increasingly popular. The supraclavicular block has been transformed by ultrasound guidance into a potentially safe superficial block. We reviewed the techniques of performing supraclavicular block with special focus on ultrasound guidance.

  13. Comparison of the biometric values obtained by two different A-mode ultrasound devices (Eye Cubed vs. PalmScan): a transversal, descriptive, and comparative study.

    Science.gov (United States)

    Velez-Montoya, Raul; Shusterman, Eugene Mark; López-Miranda, Miriam Jessica; Mayorquin-Ruiz, Mariana; Salcedo-Villanueva, Guillermo; Quiroz-Mercado, Hugo; Morales-Cantón, Virgilio

    2010-03-24

    To assess the reliability of the measurements obtained with the PalmScan, when compared with another standardized A-mode ultrasound device, and assess the consistency and correlation between the two methods. Transversal, descriptive, and comparative study. We recorded the axial length (AL), anterior chamber depth (ACD) and lens thickness (LT) obtained with two A-mode ultrasounds (PalmScan A2000 and Eye Cubed) using an immersion technique. We compared the measurements with a two-sample t-test. Agreement between the two devices was assessed with Bland-Altman plots and 95% limits of agreement. 70 eyes of 70 patients were enrolled in this study. The measurements with the Eye Cubed of AL and ACD were shorter than the measurements taken by the PalmScan. The differences were not statistically significant regarding AL (p < 0.4) but significant regarding ACD (p < 0.001). The highest agreement between the two devices was obtained during LT measurement. The PalmScan measurements were shorter, but not statistically significantly (p < 0.2). The values of AL and LT, obtained with both devices are not identical, but within the limits of agreement. The agreement is not affected by the magnitude of the ocular dimensions (but only between range of 20 mm to 27 mm of AL and 3.5 mm to 5.7 mm of LT). A correction of about 0.5 D could be considered if an intraocular lens is being calculated. However due to the large variability of the results, the authors recommend discretion in using this conversion factor, and to adjust the power of the intraocular lenses based upon the personal experience of the surgeon.

  14. ROC Analysis of Diagnostic Performance in Liver Scan

    International Nuclear Information System (INIS)

    Lee, Myung Chul; Moon, Dyuk Hyuk; Koh, Chang Soon; Matumoto, Toru; Tateno, Yukio

    1988-01-01

    To evaluate diagnostic accuracy of liver scintigraphy we analysed liver scans of 143 normal and 258 patients with various liver diseases. Three ROC curves for SOL, liver cirrhosis and diffuse liver disease were fitted using rating methods and areas under the ROC curves and their standard errors were calculated by the trapezoidal rule and the variance of the Wilcoxon statistic suggested by McNeil. We compared these results with that of National Institute of Radiological Science in Japan. 1) The sensitivity of liver scintigraphy was 74.2% in SOL, 71.8% in liver cirrhosis and 34.8% in diffuse liver disease. The specificity was 96.0% in SOL, 94.2% in liver cirrhosis and 87.6% in diffuse liver disease. 2) ROC curves of SOL and liver cirrhosis approached the upper left-hand corner closer than that of diffuse liver disease. Area (± standard error) under the ROC curve was 0.868±0.024 in SOL and 0.867±0.028 in liver cirrhosis. These were significantly higher than 0.658±0.043 in diffuse liver disease. 3) There was no interobserver difference in terms of ROC curves. But low sensitivity and high specificity of authors' SOL diagnosis suggested we used more strict decision threshold.

  15. Mesotherapy for skin rejuvenation: assessment of the subepidermal low-echogenic band by ultrasound evaluation with cross-sectional B-mode scanning.

    Science.gov (United States)

    Lacarrubba, Francesco; Tedeschi, Aurora; Nardone, Beatrice; Micali, Giuseppe

    2008-01-01

    Skin-targeted ultrasound is a noninvasive technique that has been extensively used to evaluate age-related dermal changes, and the presence of a subepidermal low-echogenic band (SLEB) has been related to chronic UVR exposure in several studies. Since SLEB echogenicity is photoage-related, the aim of this study was to evaluate, through ultrasound imaging, the effects on skin photoaging of mesotherapy, a treatment approach currently used in cosmetic dermatology for skin rejuvenation. Twenty women (mean age: 46.7 range 40-60 years) with physical signs of moderate photoaging on the dorsum of the hands were enrolled and treated with multiple microinjections of hyaluronic acid (HA) salts of biotechnological origin (1.000 Kd) every week for 4 weeks. In all subjects, ultrasound evaluation was performed at each visit and 1 week after the last treatment to evaluate SLEB echogenicity changes during treatment. At the end of study, a statistically significant (p mesotherapy with HA may be an effective treatment for skin photoaging, as confirmed by ultrasound. Follow-up investigations on larger series of patients are necessary to further evaluate the safety, effectiveness, and duration of effect of this possible therapeutic approach to skin photoaging.

  16. Abdominal ultrasound-scanning versus non-contrast computed tomography as screening method for abdominal aortic aneurysm

    DEFF Research Database (Denmark)

    Liisberg, Mads; Diederichsen, Axel C.; Lindholt, Jes S.

    2017-01-01

    Background: Validating non-contrast-enhanced computed tomography (nCT) compared to ultrasound sonography (US) as screening method for abdominal aortic aneurysm (AAA) screening. Methods: Consecutively attending men (n = 566) from the pilot study of the randomized Danish CardioVascular Screening......CT seems superior to US concerning sensitivity, and is able to detect aneurysmal lesions not detectable with US. Finally, the prevalence of AAA in Denmark seems to remain relatively high, in this small pilot study group....

  17. Outcomes of an Advanced Ultrasound Elective: Preparing Medical Students for Residency and Practice.

    Science.gov (United States)

    Prats, Michael I; Royall, Nelson A; Panchal, Ashish R; Way, David P; Bahner, David P

    2016-05-01

    Many medical specialties have adopted the use of ultrasound, creating demands for higher-quality ultrasound training at all levels of medical education. Little is known about the long-term benefit of integrating ultrasound training during undergraduate medical education. This study evaluated the effect of a longitudinal fourth-year undergraduate medical education elective in ultrasound and its impact on the future use of ultrasound in clinical practice. A cross-sectional survey of medical graduates from The Ohio State University College of Medicine (2006-2011) was done, comparing those who participated and those who did not participate in a rigorous ultrasound program for fourth-year medical students. A 38-item questionnaire queried graduates concerning ultrasound education in residency, their proficiency, and their current use of ultrasound in clinical practice. Surveys were completed by 116 respondents, for a return rate of 40.8% (116 of 284). The participants of the undergraduate medical education ultrasound elective (n = 61) reported more hours of ultrasound training after graduation (hands-on training, bedside scanning, and number of scans performed; P practice (P medical education ultrasound elective produced physicians who were more likely to seek additional training in residency, evaluate themselves as more proficient, and use ultrasound in their clinical practice. Early training in bedside ultrasound during undergraduate medical education yields physicians who are better prepared for integration of ultrasound into clinical practice. © 2016 by the American Institute of Ultrasound in Medicine.

  18. The Usefulness of Intensivist-Performed Bedside Drainage of Pleural Effusion via Ultrasound-Guided Pigtail Catheter

    Directory of Open Access Journals (Sweden)

    Joo Won Min

    2014-08-01

    CONCLUSIONS: Intensivist-performed bedside drainage of pleural effusion via ultrasound (US-guided pigtail catheter is useful and safe and may be recommended in some patients in an intensive care unit.

  19. Five-year Retrospective Review of Physician and Non-physician Performed Ultrasound in a Canadian Critical Care Helicopter Emergency Medical Service.

    Science.gov (United States)

    O'Dochartaigh, Domhnall; Douma, Matthew; MacKenzie, Mark

    2017-01-01

    To describe the use of prehospital ultrasonography (PHUS) to support interventions, when used by physician and non-physician air medical crew (AMC), in a Canadian helicopter emergency medical service (HEMS). A retrospective review was conducted of consecutive patients who underwent ultrasound examination during HEMS care from January 1, 2009 through March 10, 2014. An a priori created data form was used to record patient demographics, type of ultrasound scan performed, ultrasound findings, location of scan, type of interventions supported by PHUS, factors that affected PHUS completion, and quality indicator(s). Data analysis was performed through descriptive statistics, Student's t-test for continuous variables, Z-test for proportions, and Mann-Whitney U Test for nonparametric data. Outcomes included interventions supported by PHUS, factors associated with incomplete scans, and quality indicators associated with PHUS use. Differences between physician and AMC groups were also assessed. PHUS was used in 455 missions, 318 by AMC and 137 by physicians. In combined trauma and medical patients, in the AMC group interventions were supported by PHUS in 26% of cases (95% CI 18-34). For transport physicians the percentage support was found to be significantly greater at 45% of cases (95% CI 34-56) p = reasons included patient obesity, lack of time, patient access, and clinical reasons. Quality indicators associated with PHUS were rarely identified. The use of PHUS by both physicians and non-physicians was found to support interventions in select trauma and medical patients. Key words: emergency medical services; aircraft; helicopter; air ambulance; ultrasonography; emergency care, prehospital; prehospital emergency care.

  20. Effective doses associated with the common hybrid scans performed in nuclear medicine to adult patients

    International Nuclear Information System (INIS)

    Camacho Lopez, C.; Garcia Martinez, M. T.; Martin Vidal, J. F.; Falgas Lacuela, M.; Vercher Conejero, J. L.

    2011-01-01

    The main objective of this paper is to outline the effective dose (E) that can be taught in hybrid SPECT-CT scans and PET-CT performed more common in adult patients. E is expressed as the Natural Radiation Equivalent Time (TERN) and consider, for each scan, the percentage of the total dose due to TC.

  1. Endoscopic ultrasound guided biopsy performed routinely in lung cancer staging spares futile thoracotomies

    DEFF Research Database (Denmark)

    Larsen, Soeren S; Vilmann, Peter; Krasnik, Mark

    2005-01-01

    BACKGROUND: Up to 45% of operations with curative intent for non-small-cell lung cancer (NSCLC) can be regarded as futile, apparently because the stage of the disease is more advanced than expected preoperatively. During the past decade several studies have evaluated the usefulness of endoscopic...... ultrasound guided fine needle aspiration biopsy (EUS-FNA) in lung cancer staging with promising results. However, no randomised trials have been performed, in which a staging strategy with EUS-FNA performed in all patients is compared with a conventional workup. METHODS: Before surgery (i.e. mediastinoscopy...

  2. Safety of Ultrasound-Guided Botulinum Toxin Injections for Sialorrhea as Performed by Pediatric Otolaryngologists.

    Science.gov (United States)

    Shariat-Madar, Bahbak; Chun, Robert H; Sulman, Cecille G; Conley, Stephen F

    2016-05-01

    To evaluate incidence of complications and hospital readmission as a result of ultrasound-guided botulinum toxin injections to manage sialorrhea. Case series with chart review. Children's Hospital of Wisconsin. A case series with chart review was performed of all cases of ultrasound-guided injection of botulinum toxin by pediatric otolaryngologists from March 5, 2010, to September 26, 2014,. Primary outcomes included complications such as dysphagia, aspiration pneumonia, and motor paralysis. Secondary outcomes included hospitalization, intubation, and nasogastric tube placement. There were 48 patients, 111 interventions, and 306 intraglandular injections identified. Botulinum toxin type A and type B were utilized in 4 and 107 operative interventions, respectively. Type A was injected into 4 parotid and 4 submandibular glands, utilizing doses of 20 U per parotid and 30 U per submandibular gland. Type B was injected into 98 parotid and 200 submandibular glands, with average dosing of 923 U per parotid and 1170 U per submandibular gland, respectively. There were 2 instances of subjectively worsening of baseline dysphagia that self-resolved. No cases were complicated by aspiration pneumonia or motor paralysis. No patients required hospital readmission, intubation, or nasogastric tube placement. Prior published data indicated 16% complication incidence with ultrasound-guided injection of botulinum toxin. Our study found a low complication rate (0.6%) with ultrasound-guided injections of botulinum toxin to manage sialorrhea, without cases of aspiration pneumonia or motor paralysis. Of 306 intraglandular injections, there were 2 cases of worsening baseline subjective dysphagia that self-resolved. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... scanning or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on ... to do the scanning. The transducer is a small hand-held device that resembles a microphone, attached ...

  4. Comparison of the Diagnostic Performance of Power Doppler Ultrasound and a New Microvascular Doppler Ultrasound Technique (AngioPLUS) for Differentiating Benign and Malignant Breast Masses.

    Science.gov (United States)

    Jung, Hae Kyoung; Park, Ah Young; Ko, Kyung Hee; Koh, Jieun

    2018-03-12

    This study was performed to compare the diagnostic performance of power Doppler ultrasound (US) and a new microvascular Doppler US technique (AngioPLUS; SuperSonic Imagine, Aix-en-Provence, France) for differentiating benign and malignant breast masses. Power Doppler US and AngioPLUS findings were available in 124 breast masses with confirmed pathologic results (benign, 80 [64.5%]; malignant, 44 [35.5%]). The diagnostic performance of each tool was calculated to distinguish benign from malignant masses using a receiver operating characteristic curve analysis and compared. The area under the curve showed that AngioPLUS was superior to power Doppler US in differentiating benign from malignant breast masses, but the difference was not statistically significant. © 2018 by the American Institute of Ultrasound in Medicine.

  5. Comparison of Diagnostic Performance of Semi-Quantitative Knee Ultrasound and Knee Radiography with MRI: Oulu Knee Osteoarthritis Study

    Science.gov (United States)

    Podlipská, Jana; Guermazi, Ali; Lehenkari, Petri; Niinimäki, Jaakko; Roemer, Frank W.; Arokoski, Jari P.; Kaukinen, Päivi; Liukkonen, Esa; Lammentausta, Eveliina; Nieminen, Miika T.; Tervonen, Osmo; Koski, Juhani M.; Saarakkala, Simo

    2016-01-01

    Osteoarthritis (OA) is a common degenerative musculoskeletal disease highly prevalent in aging societies worldwide. Traditionally, knee OA is diagnosed using conventional radiography. However, structural changes of articular cartilage or menisci cannot be directly evaluated using this method. On the other hand, ultrasound is a promising tool able to provide direct information on soft tissue degeneration. The aim of our study was to systematically determine the site-specific diagnostic performance of semi-quantitative ultrasound grading of knee femoral articular cartilage, osteophytes and meniscal extrusion, and of radiographic assessment of joint space narrowing and osteophytes, using MRI as a reference standard. Eighty asymptomatic and 79 symptomatic subjects with mean age of 57.7 years were included in the study. Ultrasound performed best in the assessment of femoral medial and lateral osteophytes, and medial meniscal extrusion. In comparison to radiography, ultrasound performed better or at least equally well in identification of tibio-femoral osteophytes, medial meniscal extrusion and medial femoral cartilage morphological degeneration. Ultrasound provides relevant additional diagnostic information on tissue-specific morphological changes not depicted by conventional radiography. Consequently, the use of ultrasound as a complementary imaging tool along with radiography may enable more accurate and cost-effective diagnostics of knee osteoarthritis at the primary healthcare level. PMID:26926836

  6. Hydrogen production via reforming of biogas over nanostructured Ni/Y catalyst: Effect of ultrasound irradiation and Ni-content on catalyst properties and performance

    Energy Technology Data Exchange (ETDEWEB)

    Sharifi, Mahdi [Chemical Engineering Faculty, Sahand University of Technology, P.O. Box 51335-1996, Sahand New Town, Tabriz (Iran, Islamic Republic of); Reactor and Catalysis Research Center (RCRC), Sahand University of Technology, P.O. Box 51335-1996, Sahand New Town, Tabriz (Iran, Islamic Republic of); Haghighi, Mohammad, E-mail: haghighi@sut.ac.ir [Chemical Engineering Faculty, Sahand University of Technology, P.O. Box 51335-1996, Sahand New Town, Tabriz (Iran, Islamic Republic of); Reactor and Catalysis Research Center (RCRC), Sahand University of Technology, P.O. Box 51335-1996, Sahand New Town, Tabriz (Iran, Islamic Republic of); Abdollahifar, Mozaffar [Chemical Engineering Faculty, Sahand University of Technology, P.O. Box 51335-1996, Sahand New Town, Tabriz (Iran, Islamic Republic of); Reactor and Catalysis Research Center (RCRC), Sahand University of Technology, P.O. Box 51335-1996, Sahand New Town, Tabriz (Iran, Islamic Republic of)

    2014-12-15

    Highlights: • Synthesis of nanostructured Ni/Y catalyst by sonochemical and impregnation methods. • Enhancement of size distribution and active phase dispersion by employing sonochemical method. • Evaluation of biogas reforming over Ni/Y catalyst with different Ni-loadings. • Preparation of highly active and stable catalyst with low Ni content for biogas reforming. • Getting H{sub 2}/CO very close to equilibrium ratio by employing sonochemical method. - Abstract: The effect of ultrasound irradiation and various Ni-loadings on dispersion of active phase over zeolite Y were evaluated in biogas reforming for hydrogen production. X-ray diffraction, field emission scanning electron microscopy, energy dispersive X-ray, Brunauer–Emmett–Teller, Fourier transform infrared analysis and TEM analysis were employed to observe the characteristics of nanostructured catalysts. The characterizations implied that utilization of ultrasound irradiation enhanced catalyst physicochemical properties including high dispersion of Ni on support, smallest particles size and high catalyst surface area. The reforming reactions were carried out at GHSV = 24 l/g.h, P = 1 atm, CH{sub 4}/CO{sub 2} = 1 and temperature range of 550–850 °C. Activity test displayed that ultrasound irradiated Ni(5 wt.%)/Y had the best performance and the activity remained stable during 600 min. Furthermore, the proposed reaction mechanism showed that there are three major reaction channels in biogas reforming.

  7. Virtual reality, ultrasound-guided liver biopsy simulator: development and performance discrimination

    Science.gov (United States)

    Johnson, S J; Hunt, C M; Woolnough, H M; Crawshaw, M; Kilkenny, C; Gould, D A; England, A; Sinha, A; Villard, P F

    2012-01-01

    Objectives The aim of this article was to identify and prospectively investigate simulated ultrasound-guided targeted liver biopsy performance metrics as differentiators between levels of expertise in interventional radiology. Methods Task analysis produced detailed procedural step documentation allowing identification of critical procedure steps and performance metrics for use in a virtual reality ultrasound-guided targeted liver biopsy procedure. Consultant (n=14; male=11, female=3) and trainee (n=26; male=19, female=7) scores on the performance metrics were compared. Ethical approval was granted by the Liverpool Research Ethics Committee (UK). Independent t-tests and analysis of variance (ANOVA) investigated differences between groups. Results Independent t-tests revealed significant differences between trainees and consultants on three performance metrics: targeting, p=0.018, t=−2.487 (−2.040 to −0.207); probe usage time, p = 0.040, t=2.132 (11.064 to 427.983); mean needle length in beam, p=0.029, t=−2.272 (−0.028 to −0.002). ANOVA reported significant differences across years of experience (0–1, 1–2, 3+ years) on seven performance metrics: no-go area touched, p=0.012; targeting, p=0.025; length of session, p=0.024; probe usage time, p=0.025; total needle distance moved, p=0.038; number of skin contacts, p<0.001; total time in no-go area, p=0.008. More experienced participants consistently received better performance scores on all 19 performance metrics. Conclusion It is possible to measure and monitor performance using simulation, with performance metrics providing feedback on skill level and differentiating levels of expertise. However, a transfer of training study is required. PMID:21304005

  8. Radiologists' Performance for Detecting Lesions and the Interobserver Variability of Automated Whole Breast Ultrasound

    International Nuclear Information System (INIS)

    Kim, Sung Hun; Kang, Bong Joo; Choi, Byung Gil; Choi, Jae Jung; Lee, Ji Hye; Song, Byung Joo; Choe, Byung Joo; Park, Sarah; Kim, Hyunbin

    2013-01-01

    To compare the detection performance of the automated whole breast ultrasound (AWUS) with that of the hand-held breast ultrasound (HHUS) and to evaluate the interobserver variability in the interpretation of the AWUS. AWUS was performed in 38 breast cancer patients. A total of 66 lesions were included: 38 breast cancers, 12 additional malignancies and 16 benign lesions. Three breast radiologists independently reviewed the AWUS data and analyzed the breast lesions according to the BI-RADS classification. The detection rate of malignancies was 98.0% for HHUS and 90.0%, 88.0% and 96.0% for the three readers of the AWUS. The sensitivity and the specificity were 98.0% and 62.5% in HHUS, 90.0% and 87.5% for reader 1, 88.0% and 81.3% for reader 2, and 96.0% and 93.8% for reader 3, in AWUS. There was no significant difference in the radiologists' detection performance, sensitivity and specificity (p > 0.05) between the two modalities. The interobserver agreement was fair to good for the ultrasonographic features, categorization, size, and the location of breast masses. AWUS is thought to be useful for detecting breast lesions. In comparison with HHUS, AWUS shows no significant difference in the detection rate, sensitivity and the specificity, with high degrees of interobserver agreement

  9. Radiologists' Performance for Detecting Lesions and the Interobserver Variability of Automated Whole Breast Ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hun; Kang, Bong Joo; Choi, Byung Gil; Choi, Jae Jung; Lee, Ji Hye [Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of); Song, Byung Joo; Choe, Byung Joo [Department of General Surgery, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of); Park, Sarah [Department of Internal Medicine, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of); Kim, Hyunbin [CMC Clinical Research Coordinating Center, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of)

    2013-07-01

    To compare the detection performance of the automated whole breast ultrasound (AWUS) with that of the hand-held breast ultrasound (HHUS) and to evaluate the interobserver variability in the interpretation of the AWUS. AWUS was performed in 38 breast cancer patients. A total of 66 lesions were included: 38 breast cancers, 12 additional malignancies and 16 benign lesions. Three breast radiologists independently reviewed the AWUS data and analyzed the breast lesions according to the BI-RADS classification. The detection rate of malignancies was 98.0% for HHUS and 90.0%, 88.0% and 96.0% for the three readers of the AWUS. The sensitivity and the specificity were 98.0% and 62.5% in HHUS, 90.0% and 87.5% for reader 1, 88.0% and 81.3% for reader 2, and 96.0% and 93.8% for reader 3, in AWUS. There was no significant difference in the radiologists' detection performance, sensitivity and specificity (p > 0.05) between the two modalities. The interobserver agreement was fair to good for the ultrasonographic features, categorization, size, and the location of breast masses. AWUS is thought to be useful for detecting breast lesions. In comparison with HHUS, AWUS shows no significant difference in the detection rate, sensitivity and the specificity, with high degrees of interobserver agreement.

  10. Performances of the scanning system for the CNAO center of oncological hadron therapy

    CERN Document Server

    Giordanengo, S; Attili, A; Pardo, J; Russo, G; Taddia, G; Monaco, V; Garella, M A; Zampieri, A; Fabbricatore, P; Cirio, R; Voelker, F; Sacchi, R; Bourhaleb, F; Marchetto, F; Burini, F; Incurvati, M; Ansarinejad, A; Peroni, C

    2010-01-01

    In hadron therapy one of the most advanced methods for beam delivery is the active scanning technique which uses fast scanning magnets to drive a narrow particle beam across the target. The Centro Nazionale di Adroterapia Oncologica (CNAO) will treat tumours with this technique. The CNAO scanning system includes two identical dipole magnets for horizontal and vertical beam deflection, each one connected to a fast power supply. The dose delivery system exploits a set of monitor chambers to measure the fluence and position of the beam and drives the beam during the treatment by controlling the sequence of currents set by the power supplies. A test of the dynamic performance of the scanning system has been performed using a Hall probe to measure the field inside the magnet and the results are presented in this paper. (C) 2009 Elsevier B.V. All rights reserved.

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is located directly in front of the rectum, so the ultrasound exam is performed transrectally in order ... A follow-up examination may also be necessary so that any change in a known abnormality can ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is smaller than the standard speculum used when performing a Pap test . A protective cover is placed ... of soft tissues that do not show up well on x-ray images. Ultrasound is the preferred ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... tip of the transducer is smaller than the standard speculum used when performing a Pap test . A ... both sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... in the abdomen, arms, legs, neck and/or brain (in infants and children) or within various body organs ... or uterine cancers A transvaginal ultrasound is usually performed to view ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is Pelvic Ultrasound Imaging? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... The ultrasound exam room may have a television. Feel free to ask for your child's favorite channel. ... performed over an area of tenderness, you may feel pressure or minor pain from the transducer. Once ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view ... detect: uterine anomalies uterine scars endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is at high risk for cancer. In this case, a biopsy is performed and an ultrasound probe ... will share the results with you. In some cases, the radiologist may discuss results with you at ...

  19. Clinician-performed Beside Ultrasound for the Diagnosis of Traumatic Pneumothorax

    Directory of Open Access Journals (Sweden)

    Bon S. Ku

    2013-03-01

    Full Text Available Introduction: Prior studies have reported conflicting results regarding the utility of ultrasound in thediagnosis of traumatic pneumothorax (PTX because they have used sonologists with extensiveexperience. This study evaluates the characteristics of ultrasound for PTX for a large cohort oftrauma and emergency physicians.Methods: This was a prospective, observational study on a convenience sample of patientspresenting to a trauma center who had a thoracic ultrasound (TUS evaluation for PTX performedafter the Focused Assessment with Sonography for Trauma exam. Sonologists recorded theirfindings prior to any other diagnostic studies. The results of TUS were compared to one or more ofthe following: chest computed tomography, escape of air on chest tube insertion, or supine chestradiography followed by clinical observation.Results: There were 549 patients enrolled. The median injury severity score of the patients was 5(inter-quartile range [IQR] 1-14; 36 different sonologists performed TUS. Forty-seven of the 549patients had traumatic PTX, for an incidence of 9%. TUS correctly identified 27/47 patients with PTXfor a sensitivity of 57% (confidence interval [CI] 42-72%. There were 3 false positive cases of TUSfor a specificity of 99% (CI 98%-100%. A “wet” chest radiograph reading done in the trauma bayshowed a sensitivity of 40% (CI 23-59 and a specificity of 100% (99-100.Conclusion: In a large heterogenous group of clinicians who typically care for trauma patients, thesonographic evaluation for pneumothorax was as accurate as supine chest radiography. Thoracicultrasound may be helpful in the initial evaluation of patients with truncal trauma.

  20. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... radiation. Ultrasound scanning gives a clear picture of soft tissues that do not show up well on x-ray images. Ultrasound provides real-time imaging, making it a good tool for guiding ...

  1. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Most ultrasound scanning is noninvasive (no needles ... cord and hip joints in newborns and infants. Risks For standard diagnostic ultrasound , there are no known ...

  2. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... abdomen is a safe, noninvasive test that uses sound waves to produce a clear picture of the ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and ...

  6. Core review: physician-performed ultrasound: the time has come for routine use in acute care medicine.

    Science.gov (United States)

    Royse, Colin F; Canty, David J; Faris, John; Haji, Darsim L; Veltman, Michael; Royse, Alistair

    2012-11-01

    The use of ultrasound in the acute care specialties of anesthesiology, intensive care, emergency medicine, and surgery has evolved from discrete, office-based echocardiographic examinations to the real-time or point-of-care clinical assessment and interventions. "Goal-focused" transthoracic echocardiography is a limited scope (as compared with comprehensive examination) echocardiographic examination, performed by the treating clinician in acute care medical practice, and is aimed at addressing specific clinical concerns. In the future, the practice of surface ultrasound will be integrated into the everyday clinical practice as ultrasound-assisted examination and ultrasound-guided procedures. This evolution should start at the medical student level and be reinforced throughout specialist training. The key to making ultrasound available to every physician is through education programs designed to facilitate uptake, rather than to prevent access to this technology and education by specialist craft groups. There is evidence that diagnosis is improved with ultrasound examination, yet data showing change in management and improvement in patient outcome are few and an important area for future research.

  7. Software Application Profile: PHESANT: a tool for performing automated phenome scans in UK Biobank.

    Science.gov (United States)

    Millard, Louise A C; Davies, Neil M; Gaunt, Tom R; Davey Smith, George; Tilling, Kate

    2017-10-05

    Epidemiological cohorts typically contain a diverse set of phenotypes such that automation of phenome scans is non-trivial, because they require highly heterogeneous models. For this reason, phenome scans have to date tended to use a smaller homogeneous set of phenotypes that can be analysed in a consistent fashion. We present PHESANT (PHEnome Scan ANalysis Tool), a software package for performing comprehensive phenome scans in UK Biobank. PHESANT tests the association of a specified trait with all continuous, integer and categorical variables in UK Biobank, or a specified subset. PHESANT uses a novel rule-based algorithm to determine how to appropriately test each trait, then performs the analyses and produces plots and summary tables. The PHESANT phenome scan is implemented in R. PHESANT includes a novel Javascript D3.js visualization and accompanying Java code that converts the phenome scan results to the required JavaScript Object Notation (JSON) format. PHESANT is available on GitHub at [https://github.com/MRCIEU/PHESANT]. Git tag v0.5 corresponds to the version presented here. © The Author 2017. Published by Oxford University Press on behalf of the International Epidemiological Association.

  8. Fundamental radiological and geometric performance of two types of proton beam modulated discrete scanning systems.

    Science.gov (United States)

    Farr, J B; Dessy, F; De Wilde, O; Bietzer, O; Schönenberg, D

    2013-07-01

    The purpose of this investigation was to compare and contrast the measured fundamental properties of two new types of modulated proton scanning systems. This provides a basis for clinical expectations based on the scanned beam quality and a benchmark for computational models. Because the relatively small beam and fast scanning gave challenges to the characterization, a secondary purpose was to develop and apply new approaches where necessary to do so. The following performances of the proton scanning systems were investigated: beamlet alignment, static in-air beamlet size and shape, scanned in-air penumbra, scanned fluence map accuracy, geometric alignment of scanning system to isocenter, maximum field size, lateral and longitudinal field uniformity of a 1 l cubic uniform field, output stability over time, gantry angle invariance, monitoring system linearity, and reproducibility. A range of detectors was used: film, ionization chambers, lateral multielement and longitudinal multilayer ionization chambers, and a scintillation screen combined with a digital video camera. Characterization of the scanned fluence maps was performed with a software analysis tool. The resulting measurements and analysis indicated that the two types of delivery systems performed within specification for those aspects investigated. The significant differences were observed between the two types of scanning systems where one type exhibits a smaller spot size and associated penumbra than the other. The differential is minimum at maximum energy and increases inversely with decreasing energy. Additionally, the large spot system showed an increase in dose precision to a static target with layer rescanning whereas the small spot system did not. The measured results from the two types of modulated scanning types of system were consistent with their designs under the conditions tested. The most significant difference between the types of system was their proton spot size and associated resolution

  9. Fundamental radiological and geometric performance of two types of proton beam modulated discrete scanning systems

    Energy Technology Data Exchange (ETDEWEB)

    Farr, J. B.; Schoenenberg, D. [Westdeutsches Protonentherapiezentrum Essen, Universitaetsklinikum-Essen, Hufelandstrasse 55, 45147 Essen (Germany); Dessy, F.; De Wilde, O.; Bietzer, O. [Ion Beam Applications, Chemin du Cyclotron, 3, 1348 Louvain-la-Neuve (Belgium)

    2013-07-15

    Purpose: The purpose of this investigation was to compare and contrast the measured fundamental properties of two new types of modulated proton scanning systems. This provides a basis for clinical expectations based on the scanned beam quality and a benchmark for computational models. Because the relatively small beam and fast scanning gave challenges to the characterization, a secondary purpose was to develop and apply new approaches where necessary to do so.Methods: The following performances of the proton scanning systems were investigated: beamlet alignment, static in-air beamlet size and shape, scanned in-air penumbra, scanned fluence map accuracy, geometric alignment of scanning system to isocenter, maximum field size, lateral and longitudinal field uniformity of a 1 l cubic uniform field, output stability over time, gantry angle invariance, monitoring system linearity, and reproducibility. A range of detectors was used: film, ionization chambers, lateral multielement and longitudinal multilayer ionization chambers, and a scintillation screen combined with a digital video camera. Characterization of the scanned fluence maps was performed with a software analysis tool.Results: The resulting measurements and analysis indicated that the two types of delivery systems performed within specification for those aspects investigated. The significant differences were observed between the two types of scanning systems where one type exhibits a smaller spot size and associated penumbra than the other. The differential is minimum at maximum energy and increases inversely with decreasing energy. Additionally, the large spot system showed an increase in dose precision to a static target with layer rescanning whereas the small spot system did not.Conclusions: The measured results from the two types of modulated scanning types of system were consistent with their designs under the conditions tested. The most significant difference between the types of system was their proton

  10. Thyroid Ultrasound: Change of Inter-observer Variability and Diagnostic Performance after Training

    International Nuclear Information System (INIS)

    Moon, Hee Jung; Kim, Eun Kyung; Kwak, Jin Young; Park, Jeong Seon

    2011-01-01

    To investigate and compare inter-observer variability and diagnostic performance of thyroid ultrasound (US) between a faculty member and observing residents. From October 2007 to June 2009, 18 residents underwent training in thyroid US section. Group 1 included 8 residents that were trained for the first time and group 2 included 10 residents that were trained for the second time. US features of nodules were recorded according to the composition, echogenicity, margin, calcifications, shape, and final assessment by a faculty member and residents, respectively. Following a discussion, a faculty member performed fine needle aspiration. Then, the inter-observer variability and diagnostic performance between a faculty member and residents were investigated and compared for US. In group 1, agreement for composition in resident 1, calcification for residents 5 and 6, and shape for resident 4 were slight, moderate, moderate, and moderate, respectively. In group 2, agreement for composition in residents 1 and 10 were moderate. Substantial or greater agreement was observed more frequently in group 2 than 1. The diagnostic performances for both the faculty and residents were high and not statistically different. Agreement for US features between a faculty and residents as well as diagnostic performance were high. Moreover, diagnostic performance of residents that underwent training a second time of training was higher than residents that underwent training only once

  11. Assessment of the accuracy of an ultrasound elastography liver scanning system using a PVA-cryogel phantom with optimal acoustic and mechanical properties.

    Science.gov (United States)

    Cournane, S; Cannon, L; Browne, J E; Fagan, A J

    2010-10-07

    The accuracy of a transient elastography liver-scanning ultrasound system was assessed using a novel application of PVA-cryogel as a tissue-mimicking material with acoustic and shear elasticity properties optimized to best represent those of liver tissue. Although the liver-scanning system has been shown to offer a safer alternative for diagnosing liver cirrhosis through stiffness measurement, as compared to the liver needle biopsy exam, the scanner's accuracy has not been fully established. Young's elastic modulus values of 5-6 wt% PVA-cryogel phantoms, also containing glycerol and 0.3 µm Al(2)O(3) and 3 µm Al(2)O(3), were measured using a 'gold standard' mechanical testing technique and transient elastography. The mechanically measured values and acoustic velocities of the phantoms ranged between 1.6 and 16.1 kPa and 1540 and 1570 m s(-1), respectively, mimicking those observed in liver tissue. The values reported by the transient elastography system overestimated Young's elastic modulus values representative of the progressive stages of liver fibrosis by up to 32%. These results were attributed to the relative rather than absolute nature of the measurement arising from the single-point acoustic velocity calibration of the system, rendering the measurements critically dependent on the speed of sound of the sample under investigation. Given the wide range of acoustic velocities which exist in the liver, spanning healthy tissue to cirrhotic pathology, coupled with the system's assumption that the liver is approximately elastic when it is rather highly viscoelastic, care should be exercised when interpreting the results from this system in patient groups.

  12. Assessment of the accuracy of an ultrasound elastography liver scanning system using a PVA-cryogel phantom with optimal acoustic and mechanical properties

    Energy Technology Data Exchange (ETDEWEB)

    Cournane, S; Fagan, A J [Department of Medical Physics and Bioengineering, St James' s Hospital, Dublin 8 (Ireland); Cannon, L; Browne, J E [Medical Ultrasound Physics and Technology Group, School of Physics, Dublin Institute of Technology, Kevin' s Street, Dublin 8 (Ireland)

    2010-10-07

    The accuracy of a transient elastography liver-scanning ultrasound system was assessed using a novel application of PVA-cryogel as a tissue-mimicking material with acoustic and shear elasticity properties optimized to best represent those of liver tissue. Although the liver-scanning system has been shown to offer a safer alternative for diagnosing liver cirrhosis through stiffness measurement, as compared to the liver needle biopsy exam, the scanner's accuracy has not been fully established. Young's elastic modulus values of 5-6 wt% PVA-cryogel phantoms, also containing glycerol and 0.3 {mu}m Al{sub 2}O{sub 3} and 3 {mu}m Al{sub 2}O{sub 3}, were measured using a 'gold standard' mechanical testing technique and transient elastography. The mechanically measured values and acoustic velocities of the phantoms ranged between 1.6 and 16.1 kPa and 1540 and 1570 m s{sup -1}, respectively, mimicking those observed in liver tissue. The values reported by the transient elastography system overestimated Young's elastic modulus values representative of the progressive stages of liver fibrosis by up to 32%. These results were attributed to the relative rather than absolute nature of the measurement arising from the single-point acoustic velocity calibration of the system, rendering the measurements critically dependent on the speed of sound of the sample under investigation. Given the wide range of acoustic velocities which exist in the liver, spanning healthy tissue to cirrhotic pathology, coupled with the system's assumption that the liver is approximately elastic when it is rather highly viscoelastic, care should be exercised when interpreting the results from this system in patient groups.

  13. CT Scan-Guided Abrams' Needle Pleural Biopsy versus Ultrasound-Assisted Cutting Needle Pleural Biopsy for Diagnosis in Patients with Pleural Effusion: A Randomized, Controlled Trial.

    Science.gov (United States)

    Metintas, Muzaffer; Yildirim, Huseyin; Kaya, Tamer; Ak, Guntulu; Dundar, Emine; Ozkan, Ragip; Metintas, Selma

    2016-01-01

    Image-guided pleural biopsies, both using ultrasound (US) or computed tomography (CT), are important in the diagnosis of pleural disease. However, no consensus exists regarding which biopsy needles are appropriate for specific procedures. In this randomized, prospective study, we aimed to compare CT scan-guided pleural biopsy using an Abrams' needle (CT-ANPB) with US-assisted pleural biopsy using a cutting needle (US-CNPB) with respect to both diagnostic yield and safety. Between February 2009 and April 2013, 150 patients with exudative pleural effusion who could not be diagnosed by cytological analysis were included in the study. The patients were randomized into either the US-CNPB group or the CT-ANPB group. The two groups were compared in terms of diagnostic sensitivity and complications. Of the 150 patients enrolled in this study, 45 were diagnosed with malignant mesothelioma, 46 were diagnosed with metastatic pleural disease, 18 were diagnosed with pleural tuberculosis, 34 were diagnosed with benign pleural disease, and 7 were lost to follow-up. In the US-CNPB group, the diagnostic sensitivity was 66.7%, compared with 82.4% in the CT-ANPB group; the difference between the two groups was statistically significant (p = 0.029). The sensitivity of CT-ANPB increased to 93.7% for patients with a pleural thickness ≥1 cm. The complication rates were low and acceptable. The first diagnostic intervention that should be preferred in patients with pleural effusion and associated pleural thickening on a CT scan is CT-ANPB. US-CNPB should be used primarily in cases for which only pleural thickening but no pleural effusion is noted. © 2016 S. Karger AG, Basel.

  14. Assessment and evaluation of the performance of nuclear medicine and ultrasound imaging instrumentation

    International Nuclear Information System (INIS)

    Bergmann, Helmar; Kollmann, Christian

    1996-01-01

    The purpose of this work has been to assess the quality of instrumentation used for the collection of representative patient images during the coordinated research program entitled ''Evaluation of Imaging Procedures for the Diagnosis of Liver Diseases''. Previous work carried out during earlier phases of the project was concerned with the establishment of methods for comparison of the quality of such instrumentation. In this stage the quality of both gamma cameras and ultrasound scanners were assessed using the previously established methods. The evaluation was partly used to validate acceptable working conditions of the equipment during the collection of patient studies, partly to obtain basic data in order to be able to characterize the imaging quality of the devices. This would permit to both identify equipment unsuitable to be used in the study and to take into account the imaging quality token performing the ROC analysis of the evaluation of the patient images

  15. Construction and performance of the scanning and measuring machine HOLMES used for bubble chamber holograms

    International Nuclear Information System (INIS)

    Drevermann, H.; Geissler, K.K.; Johansson, K.E.

    1985-01-01

    The construction and performance of the scanning and measuring machine HOLMES are described. It has been used to analyse in-line holograms taken with the small bubble chamber HOBC. A total of 8000 holograms has up to now been analysed on HOLMES. (orig.)

  16. Hi-Res scan mode in clinical MDCT systems: Experimental assessment of spatial resolution performance.

    Science.gov (United States)

    Cruz-Bastida, Juan P; Gomez-Cardona, Daniel; Li, Ke; Sun, Heyi; Hsieh, Jiang; Szczykutowicz, Timothy P; Chen, Guang-Hong

    2016-05-01

    The introduction of a High-Resolution (Hi-Res) scan mode and another associated option that combines Hi-Res mode with the so-called High Definition (HD) reconstruction kernels (referred to as a Hi-Res/HD mode in this paper) in some multi-detector CT (MDCT) systems offers new opportunities to increase spatial resolution for some clinical applications that demand high spatial resolution. The purpose of this work was to quantify the in-plane spatial resolution along both the radial direction and tangential direction for the Hi-Res and Hi-Res/HD scan modes at different off-center positions. A technique was introduced and validated to address the signal saturation problem encountered in the attempt to quantify spatial resolution for the Hi-Res and Hi-Res/HD scan modes. Using the proposed method, the modulation transfer functions (MTFs) of a 64-slice MDCT system (Discovery CT750 HD, GE Healthcare) equipped with both Hi-Res and Hi-Res/HD modes were measured using a metal bead at nine different off-centered positions (0-16 cm with a step size of 2 cm); at each position, both conventional scans and Hi-Res scans were performed. For each type of scan and position, 80 repeated acquisitions were performed to reduce noise induced uncertainties in the MTF measurements. A total of 15 reconstruction kernels, including eight conventional kernels and seven HD kernels, were used to reconstruct CT images of the bead. An ex vivo animal study consisting of a bone fracture model was performed to corroborate the MTF results, as the detection of this high-contrast and high frequency task is predominantly determined by spatial resolution. Images of this animal model generated by different scan modes and reconstruction kernels were qualitatively compared with the MTF results. At the centered position, the use of Hi-Res mode resulted in a slight improvement in the MTF; each HD kernel generated higher spatial resolution than its counterpart conventional kernel. However, the MTF along the

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to ... Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces pictures ...

  18. Ultrasound imaging with a micromotor; Micromotor ni yoru choonpa imaging

    Energy Technology Data Exchange (ETDEWEB)

    Oshiro, O.; Salimuzzaman, M.; Matani, A.; Chihara, K. [Nara Institute of Science and Technology, Nara (Japan); Asao, M. [Osaka National Hospital, Osaka (Japan)

    1998-03-01

    This paper describes a new ultrasound intravascular imaging system. In this system, an ultrasound probe consists of a micromotor, an ultrasound reflecting mirror attached with the micromotor and an ultrasound transducer. Ultrasound is scanned radially by a micromotor instead of a rotation transmitting wire and the rotation of the micromotor is performed and controlled by an external magnetic field. This ultrasound imaging system with a micromotor was applied to observe the inside of blood vessels through in vitro experiments. The preliminary results suggest that this system has the sufficient ability to define the blood vessel morphology and that the simple image processing enhances signal-to-noise ratio of the reconstructed image. 12 refs., 5 figs.

  19. The infiltration of the AC joint performed by one specialist: Ultrasound versus palpation a prospective randomized pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Sabeti-Aschraf, M., E-mail: manuel.sabeti-aschraf@meduniwien.ac.a [Vienna Medical School, Department for Orthopaedics and Orthopaedic Surgery, AKH-Wien, Waehringer Guertel18-20, 1090 Vienna (Austria); Ochsner, A. [Vienna Medical School, Department for Orthopaedics and Orthopaedic Surgery, AKH-Wien, Waehringer Guertel18-20, 1090 Vienna (Austria); Schueller-Weidekamm, C. [Vienna Medical School, Department for Radiology, AKH-Wien, Waehringer Guertel 18-20, 1090 Vienna (Austria); Schmidt, M. [Vienna Medical School, Department for Orthopaedics and Orthopaedic Surgery, AKH-Wien, Waehringer Guertel18-20, 1090 Vienna (Austria); Funovics, Ph.T. [Vienna Medical School, Department for Radiology, AKH-Wien, Waehringer Guertel 18-20, 1090 Vienna (Austria); Skrbensky, G. von [Vienna Medical School, Department for Orthopaedics and Orthopaedic Surgery, AKH-Wien, Waehringer Guertel18-20, 1090 Vienna (Austria); Goll, A. [Vienna Medical School, Core Unit for Medical Statistics and Wien, Waehringer Guertel18-20, 1090 Vienna (Austria); Schatz, K.D. [Vienna Medical School, Department for Orthopaedics and Orthopaedic Surgery, AKH-Wien, Waehringer Guertel18-20, 1090 Vienna (Austria)

    2010-07-15

    Introduction: The acromio-clavicular (AC) joint is very susceptible to degenerative processes that result in pain and functional impairment. One common modality of treatment has been local infiltration of the joint space. Although this procedure has produced notable positive results, needle misplacement occurs frequently. The aim of this investigation is to evaluate the effects of an intra articular infiltration by comparing precise needle placement into the joint space using high-resolution-ultrasound with the conventional palpation technique. Methods: This prospective and randomized pilot study analysed 20 patients who were assigned either to the 'ultrasound' or the 'palpation' group. Clinical examinations were performed before treatment and at 1 h, 1 week and 3 weeks after a single infiltration of local anaesthetic and corticoid carried out by one specialist. Results: In both groups significant improvement in pain and function was obtained up to one-week post injection. Function remained significantly improved until the last follow-up and did not differ between the two groups. The agent was administered in all patients into the joint space in the ultrasound group. Conclusion: Ultrasound guided infiltration of the AC joint is an easily achieved procedure without any complications. However, clinical follow-up did not differ between free-hand and ultrasound-guided AC joint space infiltration.

  20. Who should be performing routine abdominal ultrasound? A prospective double-blind study comparing the accuracy of radiologist and radiographer

    International Nuclear Information System (INIS)

    Leslie, A.; Lockyer, H.; Virjee, J.P.

    2000-01-01

    AIM: To compare the accuracy of radiographers and radiologists in routine abdominal ultrasound. MATERIALS AND METHODS: One hundred consecutive patients attending for routine abdominal ultrasound were included. Each patient was examined by both a radiographer and radiologist. Both operators noted their findings and wrote a concluding report without conferring. Reports were compared. Where there was disagreement the patient was either re-examined by another radiologist or had further investigation. RESULTS: Of 100 patients, 52 were men and 48 were women. The age range was 19-88 years (median 52 years). Thirty-seven patients had renal tract ultrasound, one had an aortic ultrasound and 62 had general upper abdominal ultrasound. In 44 cases both operators reported the examination as normal. In 49 cases both operators reported the examinations as abnormal and there was complete agreement between the operators. In seven cases there was not complete agreement between operators. Three of these disagreements were considered minor and four major. In three of the seven cases the radiographer was correct, and in four the radiologist was correct. CONCLUSION: Experienced radiographers and radiologists are highly accurate in performing and interpreting routine abdominal sonography. Both operators missed a small minority of abnormalities. There was no statistically significant difference in the accuracy of radiographers and radiologist. Leslie, A. (2000)

  1. The infiltration of the AC joint performed by one specialist: Ultrasound versus palpation a prospective randomized pilot study

    International Nuclear Information System (INIS)

    Sabeti-Aschraf, M.; Ochsner, A.; Schueller-Weidekamm, C.; Schmidt, M.; Funovics, Ph.T.; Skrbensky, G. von; Goll, A.; Schatz, K.D.

    2010-01-01

    Introduction: The acromio-clavicular (AC) joint is very susceptible to degenerative processes that result in pain and functional impairment. One common modality of treatment has been local infiltration of the joint space. Although this procedure has produced notable positive results, needle misplacement occurs frequently. The aim of this investigation is to evaluate the effects of an intra articular infiltration by comparing precise needle placement into the joint space using high-resolution-ultrasound with the conventional palpation technique. Methods: This prospective and randomized pilot study analysed 20 patients who were assigned either to the 'ultrasound' or the 'palpation' group. Clinical examinations were performed before treatment and at 1 h, 1 week and 3 weeks after a single infiltration of local anaesthetic and corticoid carried out by one specialist. Results: In both groups significant improvement in pain and function was obtained up to one-week post injection. Function remained significantly improved until the last follow-up and did not differ between the two groups. The agent was administered in all patients into the joint space in the ultrasound group. Conclusion: Ultrasound guided infiltration of the AC joint is an easily achieved procedure without any complications. However, clinical follow-up did not differ between free-hand and ultrasound-guided AC joint space infiltration.

  2. Delphi Method Validation of a Procedural Performance Checklist for Insertion of an Ultrasound-Guided Internal Jugular Central Line.

    Science.gov (United States)

    Hartman, Nicholas; Wittler, Mary; Askew, Kim; Manthey, David

    2016-01-01

    Placement of ultrasound-guided central lines is a critical skill for physicians in several specialties. Improving the quality of care delivered surrounding this procedure demands rigorous measurement of competency, and validated tools to assess performance are essential. Using the iterative, modified Delphi technique and experts in multiple disciplines across the United States, the study team created a 30-item checklist designed to assess competency in the placement of ultrasound-guided internal jugular central lines. Cronbach α was .94, indicating an excellent degree of internal consistency. Further validation of this checklist will require its implementation in simulated and clinical environments. © The Author(s) 2014.

  3. Diagnostic Accuracy of Secondary Ultrasound Exam in Blunt Abdominal Trauma

    International Nuclear Information System (INIS)

    Rajabzadeh Kanafi, Alireza; Giti, Masoumeh; Gharavi, Mohammad Hossein; Alizadeh, Ahmad; Pourghorban, Ramin; Shekarchi, Babak

    2014-01-01

    In stable patients with blunt abdominal trauma, accurate diagnosis of visceral injuries is crucial. To determine whether repeating ultrasound exam will increase the sensitivity of focused abdominal sonography for trauma (FAST) through revealing additional free intraperitoneal fluid in patients with blunt abdominal trauma. We performed a prospective observational study by performing primary and secondary ultrasound exams in blunt abdominal trauma patients. All ultrasound exams were performed by four radiology residents who had the experience of more than 400 FAST exams. Five routine intraperitoneal spaces as well as the interloop space were examined by ultrasound in order to find free fluid. All patients who expired or were transferred to the operating room before the second exam were excluded from the study. All positive ultrasound results were compared with intra-operative and computed tomography (CT) findings and/or the clinical status of the patients. Primary ultrasound was performed in 372 patients; 61 of them did not undergo secondary ultrasound exam; thus, were excluded from the study.Three hundred eleven patients underwent both primary and secondary ultrasound exams. One hundred and two of all patients were evaluated by contrast enhanced CT scan and 31 underwent laparotomy. The sensitivity of ultrasound exam in detecting intraperitoneal fluid significantly increased from 70.7% for the primary exam to 92.7% for the secondary exam. Examining the interloop space significantly improved the sensitivity of ultrasonography in both primary (from 36.6% to 70.7%) and secondary (from 65.9% to 92.7%) exams. Performing a secondary ultrasound exam in stable blunt abdominal trauma patients and adding interloop space scan to the routine FAST exam significantly increases the sensitivity of ultrasound in detecting intraperitoneal free fluid

  4. Performance analysis of three-dimensional ridge acquisition from live finger and palm surface scans

    Science.gov (United States)

    Fatehpuria, Abhishika; Lau, Daniel L.; Yalla, Veeraganesh; Hassebrook, Laurence G.

    2007-04-01

    Fingerprints are one of the most commonly used and relied-upon biometric technology. But often the captured fingerprint image is far from ideal due to imperfect acquisition techniques that can be slow and cumbersome to use without providing complete fingerprint information. Most of the diffculties arise due to the contact of the fingerprint surface with the sensor platen. To overcome these diffculties we have been developing a noncontact scanning system for acquiring a 3-D scan of a finger with suffciently high resolution which is then converted into a 2-D rolled equivalent image. In this paper, we describe certain quantitative measures evaluating scanner performance. Specifically, we use some image software components developed by the National Institute of Standards and Technology, to derive our performance metrics. Out of the eleven identified metrics, three were found to be most suitable for evaluating scanner performance. A comparison is also made between 2D fingerprint images obtained by the traditional means and the 2D images obtained after unrolling the 3D scans and the quality of the acquired scans is quantified using the metrics.

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... sonography is performed using the same transducer. Rarely, young children may need to be sedated in order ...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... may produce minimal discomfort. If a Doppler ultrasound study is performed, you may actually hear pulse-like sounds that change in pitch as the blood flow is monitored and measured. Most ultrasound examinations ...

  7. Clinical Evaluation of Iliopsoas Strain with Findings from Diagnostic Musculoskeletal Ultrasound in Agility Performance Canines – 73 Cases

    Directory of Open Access Journals (Sweden)

    Robert Cullen

    2017-06-01

    Full Text Available Objective: Iliopsoas injury and strain is a commonly diagnosed disease process, especially amongst working and sporting canines. There has been very little published literature regarding iliopsoas injuries and there is no information regarding the ultrasound evaluation of abnormal iliopsoas muscles. This manuscript is intended to describe the ultrasound findings in 73 canine agility athletes who had physical examination findings consistent with iliopsoas discomfort. The population was chosen given the high incidence of these animals for the development of iliopsoas injury; likely due to repetitive stress.Methods: Medical records of 73 agility performance canines that underwent musculoskeletal ultrasound evaluation of bilateral iliopsoas muscle groups were retrospectively reviewed. Data included signalment, previous radiographic findings, and ultrasound findings. A 3-tier grading scheme for acute strains was used while the practitioner also evaluated for evidence of chronic injury and bursitis.Results: The majority of pathologies were localised to the tendon of insertion, with the majority being low grade I-II strains (80.8%. Tendon fibre disruption (71.2% and indistinct hypoechoic lesions (91.8% were the most common of acute changes noted. Hyperechoic chronic changes were noted in 84.9 percent of cases. Acute and chronic changes were commonly seen together (62.8%.Conclusion: Diagnostic musculoskeletal ultrasound was used to identify lesions of the iliopsoas tendon consistent with acute and chronic injury, as well as identifying the region of pathology. The majority of agility performance dogs had low grade acute strains based on the tiered system, with mixed acute and chronic lesions being noted frequently.Application: Diagnostic musculoskeletal ultrasound provides a non-invasive diagnostic modality for patients suspected of having an iliopsoas strain.

  8. Learning process for performing and analyzing 3D/4D transperineal ultrasound imaging and interobserver reliability study.

    Science.gov (United States)

    Siafarikas, F; Staer-Jensen, J; Braekken, I H; Bø, K; Engh, M Ellström

    2013-03-01

    To evaluate the learning process for acquiring three- and four-dimensional (3D/4D) transperineal ultrasound volumes of the levator hiatus (LH) dimensions at rest, during pelvic floor muscle (PFM) contraction and on Valsalva maneuver, and for analyzing the ultrasound volumes, as well as to perform an interobserver reliability study between two independent ultrasound examiners. This was a prospective study including 22 women. We monitored the learning process of an inexperienced examiner (IE) performing 3D/4D transperineal ultrasonography and analyzing the volumes. The examination included acquiring volumes during three PFM contractions and three Valsalva maneuvers. LH dimensions were determined in the axial plane. The learning process was documented by estimating agreement between the IE and an experienced examiner (E) using the intraclass correlation coefficient. Agreement was calculated in blocks of 10 ultrasound examinations and analyzed volumes. After the learning process was complete the interobserver reliability for the technique was calculated between these two independent examiners. For offline analysis of the first 10 ultrasound volumes obtained by E, good to very good agreement between E and IE was achieved for all LH measurements except for the left and right levator-urethra gap and pubic arc. For the next 10 analyzed volumes, agreement improved for all LH measurements. Volumes that had been obtained by IE and E were then re-evaluated by IE, and good to very good agreement was found for all LH measurements indicating consistency in volume acquisition. The interobserver reliability study showed excellent ICC values (ICC, 0.81-0.97) for all LH measurements except the pubic arc (ICC = 0.67). 3D/4D transperineal ultrasound is a reliable technique that can be learned in a short period of time. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  9. Hand-held ultrasound serving three EDs.

    Science.gov (United States)

    2007-02-01

    Having a portable ultrasound available to your ED will enable you to perform scans during the nighttime hours, instead of having patients wait for several hours until the radiology department opens. Additional time can be saved by having a technologist read the scans, which frees your ED physicians for other duties. Having ED docs contact the technologist directly, rather than going through a resident, also saves valuable time. Arriving at a diagnosis more quickly provides a boost to patient safety.

  10. Design and performance of the 2-ID-B scanning x-ray microscope

    International Nuclear Information System (INIS)

    McNulty, I.

    1998-01-01

    We have constructed a high resolution scanning x-ray microscope at the 2-ID-B beamline at the Advanced Photon Source for 1-4 keV x-ray imaging and microspectroscopy experiments. The microscope uses a Fresnel zone plate to focus coherent x-ray undulator radiation to a 150 nm focal spot on a sample. The spectral flux in the focus is 10 8 ph/s/0.1% BW. X-ray photons transmitted by the sample are detected by an avalanche photodiode as the sample is scanned to form an absorption image. The sample stage has both coarse and fine translation axes for raster scanning and a rotation axis for microtomography experiments. The incident x-ray beam energy can also be scanned via the 2-ID-B monochromator while the sample is kept in focus to record spatially resolved absorption spectra. We have measured the performance of the instrument with various test objects. The microscope hardware, software, and performance are discussed in this paper

  11. Evaluation of trainees' ability to perform obstetrical ultrasound using simulation: challenges and opportunities.

    Science.gov (United States)

    Chalouhi, Gihad E; Bernardi, Valeria; Gueneuc, Alexandra; Houssin, Isabelle; Stirnemann, Julien J; Ville, Yves

    2016-04-01

    Evaluation of trainee's ability in obstetrical ultrasound is a time-consuming process, which requires involving patients as volunteers. With the use of obstetrical ultrasound simulators, virtual reality could help in assessing competency and evaluating trainees in this field. The objective of the study was to test the validity of an obstetrical ultrasound simulator as a tool for evaluating trainees following structured training by comparing scores obtained on obstetrical ultrasound simulator with those obtained on volunteers and by assessing correlations between scores of images and of dexterity given by 2 blinded examiners. Trainees, taking the 2013 French national examination for the practice of obstetrical ultrasound were asked to obtain standardized ultrasound planes both on volunteer pregnant women and on an obstetrical ultrasound simulator. These planes included measurements of biparietal diameter, abdominal circumference, and femur length as well as reference planes for cardiac 4-chamber and outflow tracts, kidneys, stomach/diaphragm, spine, and face. Images were stored and evaluated subsequently by 2 national examiners who scored each picture according to previously established quality criteria. Dexterity was also evaluated and subjectively scored between 0 and 10. The Raghunathan's modification of Pearson, Filon's z, Spearman's rank correlation, and analysis of variance tests were used to assess correlations between the scores by the 2 examiners and scores of dexterity and also to compare the final scores between the 2 different methods. We evaluated 29 trainees. The mean dexterity scores in simulation (6.5 ± 2.0) and real examination (5.9 ± 2.3) were comparable (P = .31). Scores with an obstetrical ultrasound simulator were significantly higher than those obtained on volunteers (P = .027). Nevertheless, there was a good correlation between the scores of the 2 examiners judging on simulation (R = 0.888) and on volunteers (R = 0.873) (P = .81). An

  12. The Along Track Scanning Radiometer (ATSR) - Orbital performance and future developments

    Science.gov (United States)

    Sandford, M. C. W.; Edwards, T.; Mutlow, C. T.; Delderfield, J.; Llewellyn-Jones, D. T.

    1992-08-01

    The Along-Track Scanning Radiometer (ATSR), a new kind of infrared radiometer which is intended to make sea surface temperature measurements with an absolute accuracy of +/- 0.5 K averaged over cells of 0.5 deg in latitude, is discussed. The ATSR employs four detectors centered at 12, 11, 3.7, and 1.6 microns. The noise performance thermal performance, and Stirling cycle cooler performance of the ATSR on ERS-1 are examined along with 3.7 micron channel results. The calibration, structure, and data handling of the ATSRs planned for ERS-2 and for the POEM mission are examined.

  13. Observer agreement of lower limb venous reflux assessed by duplex ultrasound scanning using manual and pneumatic cuff compression in patients with chronic venous disease and controls

    DEFF Research Database (Denmark)

    Broholm, R; Kreiner, S; Bækgaard, Niels

    2011-01-01

    The study aimed to evaluate observer agreement between two experienced ultrasound operators examining deep venous reflux assessed by duplex ultrasound (DU) using either manual or pneumatic cuff compression. In addition, the two methods were compared with each other with regard to immediate "eyeba...... "eyeballing" and direct measurements of reflux time from Doppler flow curves....

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  15. Abdominal ultrasound (image)

    Science.gov (United States)

    Abdominal ultrasound is a scanning technique used to image the interior of the abdomen. Like the X- ... use high frequency sound waves to produce an image and do not expose the individual to radiation. ...

  16. Performance of a Rapid-Scan Vacuum Michelson Interferometer at the NSLS

    International Nuclear Information System (INIS)

    Brierly, P.; Dumas, P.; Smith, M.; Williams, G.P.

    2001-01-01

    A commercial Nicolet Magna series rapid-scan Michelson Fourier Transform Infrared (FTIR) was installed in a vacuum housing and integrated into the U4IR beamline at the National Synchrotron Light Source at Brookhaven National Laboratory. The frequency reference laser was mounted outside vacuum, but the moving mirror mechanism and the dynamic alignment system for the fixed mirror were in vacuum. The performance of the instrument was measured in the usual way by measuring the repeatability of data collected under specific conditions of aperture, resolution and mirror scanning velocity. We briefly discuss the beamline design, to put the interferometer in context, then present signal to noise data which we discuss in terms of both instrument performance and also storage ring stability. Under optimal conditions, the instrument has a reproducibility of 0.01% in 1 minute of measuring time at a resolution of 2 cmss, -1 , over a range from 100-3000 cm -1

  17. Maternal exposure to ambient air pollution and fetal growth in North-East Scotland: A population-based study using routine ultrasound scans.

    Science.gov (United States)

    Clemens, Tom; Turner, Steve; Dibben, Chris

    2017-10-01

    Maternal ambient air pollution exposure is associated with reduced birthweight. Few studies have examined the effect on growth in utero and none have examined the effect of exposure to particulates less than 2.5µm (PM 2.5 ) and possible effect modification by smoking status. Examine the effect of maternal exposure to ambient concentrations of PM 10 , PM 2.5 and nitrogen dioxide (NO 2 ) for in utero fetal growth, size at birth and effect modification by smoking status. Administratively acquired second and third trimester fetal measurements (bi-parietal diameter, femur length and abdominal circumference), birth outcomes (weight, crown heel length and occipito-frontal circumference) and maternal details were obtained from routine fetal ultrasound scans and maternity records (period 1994-2009). These were modelled against residential annual pollution concentrations (calendar year mean) adjusting for covariates and stratifying by smoking status. In the whole sample (n=13,775 pregnancies), exposure to PM 10 , PM 2.5 and NO 2 was associated with reductions in measurements at birth and biparietal diameter from late second trimester onwards. Among mothers who did not smoke at all during pregnancy (n=11,075), associations between biparietal diameter and pollution exposure remained significant but were insignificant among those who did smoke (n=2700). Femur length and abdominal circumference were not significantly associated with pollution exposure. Fetal growth is strongly associated with particulates exposure from later in second trimester onwards but the effect appears to be subsumed by smoking. Typical ambient exposures in this study were relatively low compared to other studies and given these results, it may be necessary to consider reducing recommended "safe" ambient air exposures. Copyright © 2017. Published by Elsevier Ltd.

  18. [Design Method Analysis and Performance Comparison of Wall Filter for Ultrasound Color Flow Imaging].

    Science.gov (United States)

    Wang, Lutao; Xiao, Jun; Chai, Hua

    2015-08-01

    The successful suppression of clutter arising from stationary or slowly moving tissue is one of the key issues in medical ultrasound color blood imaging. Remaining clutter may cause bias in the mean blood frequency estimation and results in a potentially misleading description of blood-flow. In this paper, based on the principle of general wall-filter, the design process of three classes of filters, infinitely impulse response with projection initialization (Prj-IIR), polynomials regression (Pol-Reg), and eigen-based filters are previewed and analyzed. The performance of the filters was assessed by calculating the bias and variance of a mean blood velocity using a standard autocorrelation estimator. Simulation results show that the performance of Pol-Reg filter is similar to Prj-IIR filters. Both of them can offer accurate estimation of mean blood flow speed under steady clutter conditions, and the clutter rejection ability can be enhanced by increasing the ensemble size of Doppler vector. Eigen-based filters can effectively remove the non-stationary clutter component, and further improve the estimation accuracy for low speed blood flow signals. There is also no significant increase in computation complexity for eigen-based filters when the ensemble size is less than 10.

  19. Incidental finding of knee osteoarthritis in bone scans performed in obese patients with neoplasia

    International Nuclear Information System (INIS)

    Regalado R, R.; Morales G, R.; Cano P, R.; Mendoza P, G.; Vidal N, L.

    1996-01-01

    Bone scanning performed in the Nuclear Medicine Center (IPEN-INEN) to patients with neoplastic diagnosis between January 1995 and June 1996, permitted the incidental finding of increased uptake images in the knees of 28 patients associated to an asymptomatic arthropathy: osteoarthritis. The histories and bone scanning of this patients were reviewed obtaining their weight, occupation, symptomatology, neoplastic diagnosis and previous scan diagnosis. Patients under 66 years old, asymptomatic, were included, not presenting secondary focuses, without arthropathia antecedent and with a body mass index equal or above class I. The arthropathy was classified according to the localization of the compromised compartment of the knee. >From the body mass index assessment of every patient it was obtained: Class I=12, Class II=11, Class III=3 and Class IV=1. The predominant localization of the osteoarthritic lesions was the patellar zone. We discuss factors that may influence the absence of symptoms of this disease, the relation obesity-osteoarthritis and the usefulness of bone scanning in the diagnosis of this arthropathy in these patients. (authors). 16 refs., 1 fig., 3 tabs

  20. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... scanning or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on ... to do the scanning. The transducer is a small hand-held device that resembles a microphone, attached ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  2. Training Program for Cardiology Residents to Perform Focused Cardiac Ultrasound Examination with Portable Device.

    Science.gov (United States)

    Siqueira, Vicente N; Mancuso, Frederico J N; Campos, Orlando; De Paola, Angelo A; Carvalho, Antonio C; Moises, Valdir A

    2015-10-01

    Training requirements for general cardiologists without echocardiographic expertise to perform focused cardiac ultrasound (FCU) with portable devices have not yet been defined. The objective of this study was to evaluate a training program to instruct cardiology residents to perform FCU with a hand-carried device (HCD) in different clinical settings. Twelve cardiology residents were subjected to a 50-question test, 4 lectures on basic echocardiography and imaging interpretation, the supervised interpretation of 50 echocardiograms and performance of 30 exams using HCD. After this period, they repeated the written test and were administered a practical test comprising 30 exams each (360 patients) in different clinical settings. They reported on 15 parameters and a final diagnosis; their findings were compared to the HCD exam of a specialist in echocardiography. The proportion of correct answers on the theoretical test was higher after training (86%) than before (51%; P = 0.001). The agreement was substantial among the 15 parameters analyzed (kappa ranging from 0.615 to 0.891; P < 0.001). The percentage of correct interpretation was lower for abnormal (75%) than normal (95%) items, for valve abnormalities (85%) compared to other items (92%) and for graded scale (87%) than for dichotomous (95%) items (P < 0.0001, for all). For the final diagnoses, the kappa value was higher than 0.941 (P < 0.001; 95% CI [0.914, 0.955]). The training proposed enabled residents to perform FCU with HCD, and their findings were in good agreement with those of a cardiologist specialized in echocardiography. © 2015, Wiley Periodicals, Inc.

  3. Performance Evaluation of a Synthetic Aperture Real-Time Ultrasound System

    DEFF Research Database (Denmark)

    Stuart, Matthias Bo; Tomov, Borislav Gueorguiev; Jensen, Jørgen Arendt

    2011-01-01

    This paper evaluates the signal-to-noise ratio, the time stability, and the phase difference of the sampling in the experimental ultrasound scanner SARUS: A synthetic aperture, real-time ultrasound system. SARUS has 1024 independent transmit and receive channels and is capable of handling 2D probes...... arrays (FPGAs) making it very flexible and allowing implementation of other real-time ultrasound processing methods in the future. For conventional B-mode imaging, a penetration depth around 7 cm for a 7 MHz transducer is obtained (signal-tonoise ratio of 0 dB), which is comparable to commercial...... for 3D ultrasound imaging. It samples at 12 bits per sample and has a sampling rate of 70 MHz with the possibility of decimating the sampling frequency at the input. SARUS is capable of advanced real-time computations such as synthetic aperture imaging. The system is built using fieldprogrammable gate...

  4. Surgeon-Performed Ultrasound as Preoperative Localization Study in Patients with Primary Hyperparathyroidism

    NARCIS (Netherlands)

    van Ginhoven, T. M.; Morks, A. N.; Schepers, T.; de Graaf, P. W.; Smit, P. C.

    2011-01-01

    Background: Minimally invasive parathyroidectomy is the treatment of choice for single-gland primary hyperparathyroidism. However, the exact location of the abnormal gland has to be established. Sestamibi scintigraphy, computed tomography and ultrasound (US) are commonly used modalities. We describe

  5. Standards of the Polish Ultrasound Society – update. Ultrasound examination of thyroid gland and ultrasound-guided thyroid biopsy

    Directory of Open Access Journals (Sweden)

    Anna Trzebińska

    2014-03-01

    Full Text Available Ultrasonography is a primary imaging technique in patients with suspected thyroid disease. It allows to assess the location, size and echostructures of the thyroid gland as well as detect focal lesions, along with indication of their size, echogenicity, echostructure and vascularity. Based on these features, ultrasound examination allows to predict abnormal focal lesions for biopsy and monitor the biopsy needle track. This paper presents the standards of thyroid ultrasound examination regarding ultrasound apparatus technical requirements, scanning techniques, readings, measurements, and the description of the examination. It discusses the ultrasound features of increased malignancy risk in focal lesions (nodules found in the thyroid gland. It presents indications for fine needle aspiration biopsy of the thyroid gland for the visibility of single nodules (focal lesions and numerous lesions as well as discusses contraindications for thyroid biopsy. It describes the biopsy technique, possible complications and rules for post-biopsy monitoring of benign lesions. The paper is an update of the Standards of the Polish Ultrasound Society issued in 2011. It has been prepared on the basis of current literature, taking into account the information contained in the following publications: Thyroid ultrasound examination and Recommendations of the Polish Ultrasound Society for the performance of the FNAB of the thyroid.

  6. Ten good reasons why everybody can and should perform cardiac ultrasound in the ICU.

    Science.gov (United States)

    Charron, Cyril; Repessé, Xavier; Bodson, Laurent; Au, Siu-Ming; Vieillard-Baron, Antoine

    2014-01-01

    Critical care ultrasonography (CCUS) has been defined as an ultrasound evaluation of the heart, abdomen, pleura and lungs at the bedside by the intensivist, 24/7. Within CCUS, critical care echocardiography (CCE) is used to assess cardiac function and more generally haemodynamics. Experts in haemodynamics have published a 'consensus of 16' regarding an update on haemodynamic monitoring. They reported the ten key properties of an 'ideal' haemodynamic monitoring system, which perfectly match the ten good reasons we describe here for performing CCE in critically ill patients. Even though unfortunately no evidence-based medicine study is available to support this review, especially regarding CCE-related improvement of outcome, many clinical studies have demonstrated that CCE provides measurements of relevant, accurate, reproducible and interpretable variables, is easy to use, readily available, has a rapid response time, causes no harm, and is cost-effective. Whether it is operator-independent is obviously more debatable and is discussed in this review. All these characteristics are arguments for the extensive use of CCE by intensivists. This is why experts in the field have recommended that a basic level of CCE should be included in the training of all intensivists.

  7. Impact of Music in Reducing Patient Anxiety During Pediatric Ultrasound.

    Science.gov (United States)

    Kesselman, Andrew; Bergen, Michael; Stefanov, Dimitre; Goldfisher, Rachelle; Amodio, John

    2016-03-31

    The use of noninvasive ultrasound examinations can potentially result in significant anxiety in the pediatric population. The purpose of this study was to assess the influence of music during pediatric ultrasound examinations to reduce anxiety measured by heart rate. A total of 44 patients were recruited; 21 controls and 23 experimental. Each participant was randomized to either music or no music (control) after parental consent was obtained. Pulse oximeters were used to monitor heart rate at 15 second intervals for a total of 1 minute, with mean values calculated prior to entering the procedure room, during the middle of the procedure, and after the procedure was completed. The total scan time was determined from the initial image acquisition until the last image recorded by the ultrasound technologist. At the completion of each procedure, the ultrasound technologist scored the ease of performance for the scan on a subjective scale of 1-10 based on prior experience. When utilizing music during pediatric ultrasounds examinations, our study demonstrated significantly decreased heart rate variability from pre-procedural to post-procedural periods. There was no statistical significant difference in total scan time or ultrasound technologist scoring between the two groups. This study demonstrates that music is an inexpensive and effective means of reducing anxiety during pediatric ultrasound as indicated by heart rate.

  8. Impact of music in reducing patient anxiety during pediatric ultrasound

    Directory of Open Access Journals (Sweden)

    Andrew Kesselman

    2016-03-01

    Full Text Available The use of noninvasive ultrasound examinations can potentially result in significant anxiety in the pediatric population. The purpose of this study was to assess the influence of music during pediatric ultrasound examinations to reduce anxiety measured by heart rate. A total of 44 patients were recruited; 21 controls and 23 experimental. Each participant was randomized to either music or no music (control after parental consent was obtained. Pulse oximeters were used to monitor heart rate at 15 second intervals for a total of 1 minute, with mean values calculated prior to entering the procedure room, during the middle of the procedure, and after the procedure was completed. The total scan time was determined from the initial image acquisition until the last image recorded by the ultrasound technologist. At the completion of each procedure, the ultrasound technologist scored the ease of performance for the scan on a subjective scale of 1-10 based on prior experience. When utilizing music during pediatric ultrasounds examinations, our study demonstrated significantly decreased heart rate variability from pre-procedural to post-procedural periods. There was no statistical significant difference in total scan time or ultrasound technologist scoring between the two groups. This study demonstrates that music is an inexpensive and effective means of reducing anxiety during pediatric ultrasound as indicated by heart rate.

  9. Ultrasound -- Pelvis

    Science.gov (United States)

    ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  10. Evaluation of lymph node status after neoadjuvant chemotherapy in breast cancer patients: comparison of diagnostic performance of ultrasound, MRI and ¹⁸F-FDG PET/CT.

    Science.gov (United States)

    You, S; Kang, D K; Jung, Y S; An, Y-S; Jeon, G S; Kim, T H

    2015-08-01

    To evaluate the diagnostic performance of ultrasound, MRI and fluorine-18 fludeoxyglucose positron emission tomography (¹⁸F-FDG PET)/CT for the diagnosis of metastatic axillary lymph node (ALN) after neoadjuvant chemotherapy (NAC) and to find out histopathological factors affecting the diagnostic performance of these imaging modalities. From January 2012 to November 2014, 191 consecutive patients with breast cancer who underwent NAC before surgery were retrospectively reviewed. We included 139 patients with ALN metastasis that was confirmed on fine needle aspiration or core needle biopsy at initial diagnosis. After NAC, 39 (28%) patients showed negative conversion of ALN on surgical specimens of sentinel lymph node (LN) or ALN. The sensitivity of ultrasound, MRI and PET/CT was 50% (48/96), 72% (70/97) and 22% (16/73), respectively. The specificity of ultrasound, MRI and PET/CT was 77% (30/39), 54% (21/39) and 85% (22/26), respectively. The Az value of combination of ultrasound and PET/CT was the highest (0.634) followed by ultrasound (0.626) and combination of ultrasound, MRI and PET/CT (0.617). The size of tumour deposit in LN and oestrogen receptor was significantly associated with the diagnostic performance of ultrasound (p performance of PET/CT (p = 0.023, p = 0.002, p = 0.036, p = 0.044 and p = 0.008, respectively). On multivariate logistic regression analysis, size of tumour deposit within LN was identified as being independently associated with diagnostic performance of ultrasound [odds ratio, 13.07; 95% confidence interval (CI), 2.95-57.96] and PET/CT (odds ratio, 6.47; 95% CI, 1.407-29.737). Combination of three imaging modalities showed the highest sensitivity, and PET/CT showed the highest specificity for the evaluation of ALN metastasis after NAC. Ultrasound alone or combination of ultrasound and PET/CT showed the highest positive-predictive value. The size of tumour deposit within ALN was significantly associated with

  11. Use of 'non-medical' ultrasound imaging before mid-pregnancy in Copenhagen

    DEFF Research Database (Denmark)

    Thorup, Tine J; Zingenberg, Helle

    2015-01-01

    We have investigated prospectively how many pregnant women purchase ultrasound imaging before week 20, why they purchase scans, and which professional skills and certifications women expect the person performing the scan to have. In addition, we wanted to investigate whether the women were aware...... shows that there is a significant demand among pregnant women for commercial ultrasound imaging of their fetus for various reasons. Knowledge of certifications and requirements for legal authorization is, however, sparse....

  12. Novel Scanning Lens Instrument for Evaluating Fresnel Lens Performance: Equipment Development and Initial Results (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Herrero, R.; Miller, D. C.; Kurtz, S. R.; Anton, I.; Sala, G.

    2013-07-01

    A system dedicated to the optical transmittance characterization of Fresnel lenses has been developed at NREL, in collaboration with the UPM. The system quantifies the optical efficiency of the lens by generating a performance map. The shape of the focused spot may also be analyzed to understand change in the lens performance. The primary instrument components (lasers and CCD detector) have been characterized to confirm their capability for performing optical transmittance measurements. Measurements performed on SoG and PMMA lenses subject to a variety of indoor conditions (e.g., UV and damp heat) identified differences in the optical efficiency of the evaluated lenses, demonstrating the ability of the Scanning Lens Instrument (SLI) to distinguish between the aged lenses.

  13. Effects of using simulation versus CD-ROM in the performance of ultrasound-guided regional anesthesia.

    Science.gov (United States)

    Gasko, John; Johnson, Arthur; Sherner, John; Craig, John; Gegel, Brian; Burgert, James; Sama, Samuel; Franzen, Thomas

    2012-08-01

    The purpose of this study was to determine which method of teaching, CD-ROM, simulation, or a combination of both, was more effective in increasing the performance of ultrasound-guided regional anesthesia. No studies have investigated these methods. The framework for this study was critical thinking. The study was a prospective, mixed (between and within) subjects, experimental design. The sample consisted of 29 student registered nurse anesthetists randomly assigned to 1 of 3 groups: CD-ROM (n = 11), simulation (n = 11), and combination (n = 7). All groups were evaluated by the use of cadavers before and 2 months after the intervention using a valid and reliable instrument of performance. A repeated-measures analysis of variance indicated that the combination was significantly better than the CD-ROM and simulation (P teaching ultrasound-guided regional anesthesia techniques.

  14. The Interobserver Variability and Diagnostic Performance of 3-Dimensional Breast Ultrasound

    International Nuclear Information System (INIS)

    Lyou, Chae Yeon; Kim, Sun Mi; Jang, Mi Jung; Kim, Sung Won; Kang, Eun Young; Park, So Yeon; Moon, Woo Kyung

    2011-01-01

    We wanted to evaluate the interobserver variability and diagnostic performance of 3-dimensional (3D) breast ultrasound (US) as compared with that of 2- dimensional (2D) US. We included 150 patients who received US-guided core biopsy and 3D US between June 2009 and April 2010. Three breast imaging radiologists analyzed the 2D and 3D US images using the Breast Imaging Reporting and Data System (BI-RADS) lexicon. The intra-observer agreement and inter-observer agreement were calculated. The sensitivity and specificity of 2D and 3D US were evaluated. The intra-observer agreement between 2D and 3D US was mostly slight or fair agreement. However, in terms of the final category, there was substantial agreement for all three radiologists. The inter-observer agreement of 3D US was similar to that of 2D US (moderate agreement for shape, orientation, circumscribed margin and boundary: fair agreement for indistinct margin, angular margin, microlobulated margin, echo pattern and final category). The sensitivity of 3D US for breast cancer was higher than that of 2D US for two radiologists (2D vs. 3D for reader 2: 55.8% vs. 61.5%, 2D vs. 3D for reader 3: 59.6% vs. 63.5%), and the specificity of 3D US was lower than that of 2D US for all the readers (2D vs. 3D for reader 1: 90.8% vs. 86.7%, 2D vs. 3D for reader 2: 90.8% vs. 87.8%, 2D vs. 3D for reader 3: 94.9% vs. 90.8%), but the difference was not significant (p ≥ 0.05). The interobserver variability and diagnostic performance of 3D breast US were similar to those of 2D US

  15. Performance and ultrasound measurements of beef cattle fed diets based on whole corn or oats grains

    Directory of Open Access Journals (Sweden)

    Hugo M Arelovich

    2013-09-01

    Full Text Available This study intended to contrast dietary effects of whole grain oats versus corn included in rations with moderate roughage content on animal performance, beef ultrasound measurements, rumen and blood parameters. Ten Aberdeen Angus steers (203 kg in individual pens were fed twice daily on either whole oats (OD or corn (CD based diets. Measurements were: DM intake (DMI, average daily gain (ADG, feed to gain ratio (F/G; back fat (BF and rib eye area (RA; blood parameters. Four cannulated steers were used to study rumen pH, NH3-N and grain degradability. Rations dietary components were 55% grain, 30.1% barley straw, and 10.6% whole soybeans. Despite calculated higher ME supply (P = 0.0887 no differences were found for DMI, ADG, or F/G. Metabolizable protein intake (19.4% was larger and degradable protein intake (43.3% smaller for CD compared with OD (P < 0.01. The growth rate (cm² d-1 for RA was 40% grater for OD, but larger BF deposition (P = 0.0787 was found for CD. Blood Mg was higher for OD (p = 0.0564, nevertheless other blood parameters remained unaffected. Rumen pH and NH3-N were not influenced by diet, variations were only observed within time periods. Rumen pH decreased linearly from 7.05 to 6.13 and 7.11 to 6.37 for OD and CD respectively (P < 0.05. Minimum NH3-N concentrations (mg dL-1 were reached 12 and 18 h after morning meal for OD (7.10 and CD (5.82 respectively. Rumen degradation was larger for oats than corn. Whole oats rather than corn fed up to 55% of total DM seems to improve protein deposition, without significant changes in animal performance, rumen environment or blood parameters.

  16. Going beyond a First Reader: A Machine Learning Methodology for Optimizing Cost and Performance in Breast Ultrasound Diagnosis.

    Science.gov (United States)

    Venkatesh, Santosh S; Levenback, Benjamin J; Sultan, Laith R; Bouzghar, Ghizlane; Sehgal, Chandra M

    2015-12-01

    The goal of this study was to devise a machine learning methodology as a viable low-cost alternative to a second reader to help augment physicians' interpretations of breast ultrasound images in differentiating benign and malignant masses. Two independent feature sets consisting of visual features based on a radiologist's interpretation of images and computer-extracted features when used as first and second readers and combined by adaptive boosting (AdaBoost) and a pruning classifier resulted in a very high level of diagnostic performance (area under the receiver operating characteristic curve = 0.98) at a cost of pruning a fraction (20%) of the cases for further evaluation by independent methods. AdaBoost also improved the diagnostic performance of the individual human observers and increased the agreement between their analyses. Pairing AdaBoost with selective pruning is a principled methodology for achieving high diagnostic performance without the added cost of an additional reader for differentiating solid breast masses by ultrasound. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  17. Follow-up of recurrences of limb soft tissue sarcomas in patients with localized disease: performance of ultrasound

    International Nuclear Information System (INIS)

    Tagliafico, Alberto; Truini, Mauro; Spina, Bruno; Cambiaso, Paolo; Zaottini, Federico; Bignotti, Bianca; Derchi, Lorenzo E.; Martinoli, Carlo; Calabrese, Massimo

    2015-01-01

    To evaluate diagnostic performance of ultrasound in the detection of local recurrences in patients with localized soft tissue sarcomas of the limb. An analysis of patients treated for soft tissue sarcomas between 2005 and April 2014 was performed. Sixty-eight patients (men/women, 36:32; age range, 18-84 years) were evaluated. Sensitivity, specificity with 95 % confidence intervals (CIs), positive predictive value (PPV), pre-test probability (the prevalence), negative predictive value (NPV), likelihood ratio for positive results (LH+), accuracy and post-test probability (post-P) of ultrasound were reported on a per patient basis using surgical findings and clinical follow-up as reference standard. Effects of independent variables (US equipment, age and sex, body mass index, radiologist) were considered. Comparison with MR was also performed. The overall sensitivity and specificity were 0.88 (0.60-0.94) and 0.94 (0.86-0.98). PPV, pre-test probability, NPV, LH+, accuracy and post-P: 0.83/0.25/0.96/14.9/0.92/0.83. There were two false negative cases both graded as G3 and deeply located and three false positive US cases. Diagnostic accuracy was not dependent by US machine (p = 0.08), age and sex (p = 0.16), body mass index (p = 0.07) and radiologists (p = 0.07). Diagnostic accuracy of ultrasound was relatively high. Negative US results excluded the presence of a local recurrence with acceptable accuracy. (orig.)

  18. Asymmetric actuating structure generates negligible influence on the supporting base for high performance scanning probe microscopies

    Science.gov (United States)

    Yi Yan, Gang; Bin Liu, Yong; Hua Feng, Zhi

    2014-02-01

    An asymmetric actuating structure generating negligible influence on the supporting base for high performance scanning probe microscopies is proposed in this paper. The actuator structure consists of two piezostacks, one is used for actuating while the other is for counterbalancing. In contrast with balanced structure, the two piezostacks are installed at the same side of the supporting base. The effectiveness of the structure is proved by some experiments with the actuators fixed to the free end of a cantilever. Experimental results show that almost all of the vibration modes of the cantilever are suppressed effectively at a wide frequency range of 90 Hz-10 kHz.

  19. Impact of ultrasound video transfer on the practice of ultrasound

    Science.gov (United States)

    Duerinckx, Andre J.; Hayrapetian, Alek S.; Grant, Edward G.; Valentino, Daniel J.; Rahbar, Darius; Kiszonas, Mike; Franco, Ricky; Melany, Michelle; Narin, Sherelle L.; Ragavendra, Nagesh

    1996-05-01

    Sonography can be highly dependent on real-time imaging and as such is highly physician intensive. Such situations arise mostly during complicated ultrasound radiology studies or echocardiology examinations. Under those circumstances it would be of benefit to transmit real-time images beyond the immediate area of the ultrasound laboratory when a physician is not on location. We undertook this study to determine if both static and dynamic image transfer to remote locations might be accomplished using an ultrafast ATM network and PACS. Image management of the local image files was performed by a commercial PACS from AGFA corporation. The local network was Ethernet based, and the global network was based on Asynchronous Transfer Mode (ATM, rates up to 100 Mbits/sec). Real-time image transfer involved two teaching hospitals, one of which had 2 separate ultrasound facilities. Radiologists consulted with technologists via telephone while the examinations were being performed. The applications of ATM network providing real time video for ultrasound imaging in a clinical environment and its potential impact on health delivery and clinical teaching. This technology increased technologist and physician productivity due to the elimination of commute time for physicians and waiting time for technologists and patients. Physician confidence in diagnosis increased compared to reviewing static images alone. This system provided instant access for radiologists to real-time scans from remote sites. Image quality and frame rate were equivalent to the original. The system increased productivity by allowing physicians to monitor studies at multiple sites simultaneously.

  20. Experimental performance assessment of the sub-band minimum variance beamformer for ultrasound imaging

    DEFF Research Database (Denmark)

    Diamantis, Konstantinos; Greenaway, Alan H.; Anderson, Tom

    2017-01-01

    Recent progress in adaptive beamforming techniques for medical ultrasound has shown that current resolution limits can be surpassed. One method of obtaining improved lateral resolution is the Minimum Variance (MV) beamformer. The frequency domain implementation of this method effectively divides...... the broadband ultrasound signals into sub-bands (MVS) to conform with the narrow-band assumption of the original MV theory. This approach is investigated here using experimental Synthetic Aperture (SA) data from wire and cyst phantoms. A 7 MHz linear array transducer is used with the SARUS experimental...... ultrasound scanner for the data acquisition. The lateral resolution and the contrast obtained, are evaluated and compared with those from the conventional Delay-and-Sum (DAS) beamformer and the MV temporal implementation (MVT). From the wire phantom the Full-Width-at-Half-Maximum (FWHM) measured at a depth...

  1. Experimental performance assessment of the sub-band minimum variance beamformer for ultrasound imaging

    DEFF Research Database (Denmark)

    Diamantis, Konstantinos; Greenaway, Alan H.; Anderson, Tom

    2017-01-01

    Recent progress in adaptive beamforming techniques for medical ultrasound has shown that current resolution limits can be surpassed. One method of obtaining improved lateral resolution is the Minimum Variance (MV) beamformer. The frequency domain implementation of this method effectively divides...... the broadband ultrasound signals into sub-bands (MVS) to conform with the narrow-band assumption of the original MV theory. This approach is investigated here using experimental Synthetic Aperture (SA) data from wire and cyst phantoms. A 7 MHz linear array transducer is used with the SARUS experimental...

  2. Detecting Distributed Scans Using High-Performance Query-DrivenVisualization

    Energy Technology Data Exchange (ETDEWEB)

    Stockinger, Kurt; Bethel, E. Wes; Campbell, Scott; Dart, Eli; Wu,Kesheng

    2006-09-01

    Modern forensic analytics applications, like network trafficanalysis, perform high-performance hypothesis testing, knowledgediscovery and data mining on very large datasets. One essential strategyto reduce the time required for these operations is to select only themost relevant data records for a given computation. In this paper, wepresent a set of parallel algorithms that demonstrate how an efficientselection mechanism -- bitmap indexing -- significantly speeds up acommon analysist ask, namely, computing conditional histogram on verylarge datasets. We present a thorough study of the performancecharacteristics of the parallel conditional histogram algorithms. Asacase study, we compute conditional histograms for detecting distributedscans hidden in a dataset consisting of approximately 2.5 billion networkconnection records. We show that these conditional histograms can becomputed on interactive timescale (i.e., in seconds). We also show how toprogressively modify the selection criteria to narrow the analysis andfind the sources of the distributed scans.

  3. Value of Artisanal Simulators to Train Veterinary Students in Performing Invasive Ultrasound-Guided Procedures

    Science.gov (United States)

    Hage, Maria Cristina F. N. S.; Massaferro, Ana Beatriz; Lopes, Érika Rondon; Beraldo, Carolina Mariano; Daniel, Jéssika

    2016-01-01

    Pericardial effusion can lead to cardiac tamponade, which endangers an animal's life. Ultrasound-guided pericardiocentesis is used to remove abnormal liquid; however, it requires technical expertise. In veterinary medical education, the opportunity to teach this procedure to save lives during emergencies is rare; therefore, simulators are…

  4. Using virtual-reality simulation to assess performance in endobronchial ultrasound

    DEFF Research Database (Denmark)

    Konge, Lars; Annema, Jouke; Clementsen, Paul

    2013-01-01

    For optimal treatment of patients with non-small cell lung carcinoma, it is essential to have physicians with competence in endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). EBUS training and certification requirements are under discussion and the establishment of basi...

  5. Performance analysis of a compact and low-cost mapping-grade mobile laser scanning system

    Science.gov (United States)

    Julge, Kalev; Vajakas, Toivo; Ellmann, Artu

    2017-10-01

    The performance of a low-cost, self-contained, compact, and easy to deploy mapping-grade mobile laser scanning (MLS) system, which is composed of a light detection and ranging sensor Velodyne VLP-16 and a dual antenna global navigation satellite system/inertial navigation system SBG Systems Ellipse-D, is analyzed. The field tests were carried out in car-mounted and backpack modes for surveying road engineering structures (such as roads, parking lots, underpasses, and tunnels) and coastal erosion zones, respectively. The impact of applied calculation principles on trajectory postprocessing, direct georeferencing, and the theoretical accuracy of the system is analyzed. A calibration method, based on Bound Optimization BY Quadratic Approximation, for finding the boresight angles of an MLS system is proposed. The resulting MLS point clouds are compared with high-accuracy static terrestrial laser scanning data and survey-grade MLS data from a commercially manufactured MLS system. The vertical, horizontal, and relative accuracy are assessed-the root-mean-square error (RMSE) values were determined to be 8, 15, and 3 cm, respectively. Thus, the achieved mapping-grade accuracy demonstrates that this relatively compact and inexpensive self-assembled MLS can be successfully used for surveying the geometry and deformations of terrain, buildings, road, and other engineering structures.

  6. Evaluation of a point-of-care ultrasound scan list in a resource-limited emergency centre in Addis Ababa Ethiopia

    Directory of Open Access Journals (Sweden)

    Maja Stachura

    2017-09-01

    Discussion: In this urban, low-resource, academic EC in Ethiopia, POCUS provided clinically relevant information for patient management, particularly for polytrauma, undifferentiated shock and undifferentiated dyspnea. Results have subsequently been used to develop a locally relevant emergency department ultrasound curriculum for Ethiopia’s first emergency medicine residency program.

  7. ULTRASOUND AND COMPUTED TOMOGRAPHIC DIAGNOSIS OF OPTIC NERVE TUMORS

    Directory of Open Access Journals (Sweden)

    S. V. Saakyan

    2012-01-01

    Full Text Available A comprehensive examination was made in 93 patients, including 18 children, with tumors of the optic nerve (ON. Duplex ultrasound scanning was performed in 39 patients, of them there were 11 patients with ON gliomas and 28 with ON meningiomas. The specific computed tomographic and echographic signs of ON glioma and meningiomas were detected. The studies have shown that duplex ultrasound scanning and structural computed tomography of orbital sockets are highly informative complementary imaging procedures for ON tumors, which permits one to make their correct diagnosis, to specify surgical volume, and to plan adequate treatment.

  8. Prehospital Ultrasound

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Full Text Available Ultrasound is a commonly used diagnostic tool in clinical conditions. With recent developments in technology, use of portable ultrasound devices has become feasible in prehospital settings. Many studies also proved the feasibility and accuracy of prehospital ultrasound. In this article, we focus on the use of prehospital ultrasound, with emphasis on trauma and chest ultrasound.

  9. C-Scan Performance Test of Under-Sodium ultrasonic Waveguide Sensor in Sodium

    International Nuclear Information System (INIS)

    Joo, Young Sang; Bae, Jin Ho; Kim, Jong Bum

    2011-01-01

    Reactor core and in-vessel structures of a sodium-cooled fast (SFR) are submerged in opaque liquid sodium in the reactor vessel. The ultrasonic inspection techniques should be applied for observing the in-vessel structures under hot liquid sodium. Ultrasonic sensors such as immersion sensors and rod-type waveguide sensors have developed in order to apply under-sodium viewing of the in-vessel structures of SFR. Recently the novel plate-type ultrasonic waveguide sensor has been developed for the versatile application of under-sodium viewing in SFR. In previous studies, the ultrasonic waveguide sensor module was designed and manufactured, and the feasibility study of the ultrasonic waveguide sensor was performed. To improve the performance of the ultrasonic waveguide sensor in the under-sodium application, a new concept of ultrasonic waveguide sensors with a Be coated SS304 plate is suggested for the effective generation of a leaky wave in liquid sodium and the non-dispersive propagation of A 0 -mode Lamb wave in an ultrasonic waveguide sensor. In this study, the C-scan performance of the under-sodium ultrasonic waveguide sensor in sodium has been investigated by the experimental test in sodium. The under-sodium ultrasonic waveguide sensor and the sodium test facility with a glove box system and a sodium tank are designed and manufactured to carry out the performance test of under-sodium ultrasonic waveguide sensor in sodium environment condition

  10. Optical 3D scans for orthodontic diagnostics performed on full-arch impressions. Completeness of surface structure representation.

    Science.gov (United States)

    Vogel, Annike B; Kilic, Fatih; Schmidt, Falko; Rübel, Sebastian; Lapatki, Bernd G

    2015-11-01

    The purpose of this work was to evaluate the completeness of surface structure representation offered by full-arch impression scans in different situations of tooth (mal)alignment and whether this completeness could be improved by performing rescans on the same impressions reduced sequentially to different levels of gingival height and by adding extra single scans to the number of single scans recommended by the manufacturer. Three pairs of full-arch resin models were used as reference, characterized either by normal occlusion, by anterior diastematic protrusion (and edentulous spaces in the lower posterior segments), or by anterior crowding. An alginate impression of each arch was taken and digitized with a structured-light scanner, followed by three rescans with the impression cut back to 10, 5, and 1 mm of gingival height. Both the initial scan and the rescans were performed both with 19 basic single scans and with 10 extra single scans. Each impression scan was analyzed for quantitative completeness relative to its homologous direct scan of the original resin model. In addition, the topography of voids in the resultant digital model was assessed by visual inspection. Compared to the homologous reference scans of the original resin models, completeness of the original impression scans--in the absence of both gingival cutback and extra single scans--was 97.23 ± 0.066% in the maxilla or 95.72 ± 0.070% in the mandible with normal occlusion, 91.11 ± 0.132% or 96.07 ± 0.109% in the arches with anterior diastematic protrusion, and 98.24 ± 0.085% or 93.39 ± 0.146% in those with anterior crowding. Gingival cutback and extra single scans were found to improve these values up to 100.35 ± 0.066% or 99.53 ± 0.070% in the arches with normal occlusion, 91.77 ± 0.132% or 97.95 ± 0.109% in those with anterior diastematic protrusion, and 98.59 ± 0.085% or 98.96 ± 0.146% in those with anterior crowding. In strictly quantitative terms, the impression scans did capture

  11. Construction and performance of a dilution-refrigerator based spectroscopic-imaging scanning tunneling microscope.

    Science.gov (United States)

    Singh, U R; Enayat, M; White, S C; Wahl, P

    2013-01-01

    We report on the set-up and performance of a dilution-refrigerator based spectroscopic imaging scanning tunneling microscope. It operates at temperatures below 10 mK and in magnetic fields up to 14T. The system allows for sample transfer and in situ cleavage. We present first-results demonstrating atomic resolution and the multi-gap structure of the superconducting gap of NbSe(2) at base temperature. To determine the energy resolution of our system we have measured a normal metal/vacuum/superconductor tunneling junction consisting of an aluminum tip on a gold sample. Our system allows for continuous measurements at base temperature on time scales of up to ≈170 h.

  12. Performance Evaluation of the IrisScan2200 Against Four Respirator Masks; TOPICAL

    International Nuclear Information System (INIS)

    WRIGHT, LARRY J.; TERRY, PRESTON L.

    2002-01-01

    The use of biometrics for the identification of individuals is becoming more prevalent in society and in the general government community. As the demand for these devices increases, it becomes necessary for the user community to have the facts needed to determine which device is the most appropriate for any given application. One such application is the use of biometric devices in areas where an individual may not be able to present a biometric feature that requires contact with the identifier (e.g., when dressed in anti-contamination suits or when wearing a respirator). This paper discusses a performance evaluation conducted on the IrisScan2200 from Iridian Technologies to determine if it could be used in such a role

  13. Design and performance of a compact scanning transmission X-ray microscope at the Photon Factory

    Energy Technology Data Exchange (ETDEWEB)

    Takeichi, Y., E-mail: yasuo.takeichi@kek.jp; Mase, K.; Ono, K. [Institute of Materials Structure Science, High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba 305-0801 (Japan); Department of Materials Structure Science, SOKENDAI (The Graduate University for Advanced Studies), 1-1 Oho, Tsukuba 305-0801 (Japan); Inami, N. [Institute of Materials Structure Science, High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba 305-0801 (Japan); Suga, H. [Department of Earth and Planetary Systems Science, Hiroshima University, 1-3-1 Kagamiyama, Higashi-Hiroshima 739-8526 (Japan); Miyamoto, C. [Department of Earth and Planetary Systems Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku 113-0033 (Japan); Ueno, T. [National Institute for Materials Science, 1-2-1 Sengen, Tsukuba 305-0047 (Japan); Takahashi, Y. [Institute of Materials Structure Science, High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba 305-0801 (Japan); Department of Earth and Planetary Systems Science, Hiroshima University, 1-3-1 Kagamiyama, Higashi-Hiroshima 739-8526 (Japan); Department of Earth and Planetary Systems Science, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku 113-0033 (Japan)

    2016-01-15

    We present a new compact instrument designed for scanning transmission X-ray microscopy. It has piezo-driven linear stages, making it small and light. Optical components from the virtual source point to the detector are located on a single optical table, resulting in a portable instrument that can be operated at a general-purpose spectroscopy beamline without requiring any major reconstruction. Careful consideration has been given to solving the vibration problem common to high-resolution microscopy, so as not to affect the spatial resolution determined by the Fresnel zone plate. Results on bacteriogenic iron oxides, single particle aerosols, and rare-earth permanent magnets are presented as examples of its performance under diverse applications.

  14. Indications for and comparative diagnostic value of combined ultrasound and X-ray mammography

    International Nuclear Information System (INIS)

    Novak, D.

    1983-01-01

    A standardised method of ultrasound mammography is described. In order to achieve the same position, form, and shape of the breast as during roentgen mammography a Lucite plate in horizontal, and vertical position us used. Ultrasound contact scanning of the whole breast is carried out in cranio-caudal as well as in medio-lateral direction of the ultrasound beam. Ultrasound scanning is performed with the compression of the breast corresponding to the compression during roentgen mammography. It was found that the ultrasound breast examination combined with X-ray mammography optimizes the differentiation between benign and malignant masses and therefore may reduce the incidence of breast biopsy. A combined use of both examination modalities in the evaluation of the breast is advocated. (orig.)

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a pelvic ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are ... Ultrasound page for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: pelvic ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ... pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Obstetrical Ultrasound page for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: ...

  19. Quality of pediatric abdominal CT scans performed at a dedicated children's hospital and its referring institutions: a multifactorial evaluation

    International Nuclear Information System (INIS)

    Snow, Aisling; Milliren, Carly E.; Graham, Dionne A.; Callahan, Michael J.; MacDougall, Robert D.; Robertson, Richard L.; Taylor, George A.

    2017-01-01

    Pediatric patients requiring transfer to a dedicated children's hospital from an outside institution may undergo CT imaging as part of their evaluation. Whether this imaging is performed prior to or after transfer has been shown to impact the radiation dose imparted to the patient. Other quality variables could also be affected by the pediatric experience and expertise of the scanning institution. To identify differences in quality between abdominal CT scans and reports performed at a dedicated children's hospital, and those performed at referring institutions. Fifty consecutive pediatric abdominal CT scans performed at outside institutions were matched (for age, gender and indication) with 50 CT scans performed at a dedicated freestanding children's hospital. We analyzed the scans for technical parameters, report findings, correlation with final clinical diagnosis, and clinical utility. Technical evaluation included use of intravenous and oral contrast agents, anatomical coverage, number of scan phases and size-specific dose estimate (SSDE) for each scan. Outside institution scans were re-reported when the child was admitted to the children's hospital; they were also re-interpreted for this study by children's hospital radiologists who were provided with only the referral information given in the outside institution's report. Anonymized original outside institutional reports and children's hospital admission re-reports were analyzed by two emergency medicine physicians for ease of understanding, degree to which the clinical question was answered, and level of confidence in the report. Mean SSDE was lower (8.68) for children's hospital scans, as compared to outside institution scans (13.29, P = 0.03). Concordance with final clinical diagnosis was significantly lower for original outside institution reports (38/48, 79%) than for both the admission and study children's hospital reports (48/50, 96%; P = 0.005). Children's hospital admission reports were rated higher

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: ...

  1. The Use of Ultrasound to Exclude Extremity Fractures in Adults

    DEFF Research Database (Denmark)

    Døssing, Kaj Verner; Mechlenburg, Inger; Hansen, Lars Bolvig

    2017-01-01

    for a conventional radiographic examination of a suspected extremity fracture. No additional clinical examination was performed. Ultrasound examination was consistently carried out prior to conventional radiographic examination, which was regarded as the gold standard. At the end of the study, the positive scans...

  2. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... children. Except for traumatic injury, appendicitis is the most common reason for emergency abdominal surgery. Ultrasound imaging ... of page How is the procedure performed? For most ultrasound exams, you will be positioned lying face- ...

  3. Lumbar epidural depth using transverse ultrasound scan and its correlation with loss of resistance technique: A prospective observational study in Indian population.

    Science.gov (United States)

    Chauhan, Amit Kumar; Bhatia, Rohan; Agrawal, Sanjay

    2018-01-01

    The objective of the present study was to evaluate the skin-epidural space distance as assessed by ultrasonography and conventional loss of resistance (LOR) technique and to find the correlation of epidural depth with body mass index (BMI). Ninety-eight patients of either sex, American Society of Anesthesiology I/II, BMI transverse plane at L3-L4 intervertebral space. Thereafter, the epidural depth from skin was assessed with conventional LOR method while performing the epidural. The needle depth (ND) was measured using a sterile linear scale, and any change in the needle direction or intervertebral space was noted. The patients were demographically similar. Depth of epidural space measured by US depth (UD) was 3.96 ± 0.44 cm (range 3.18-5.44 cm) and by ND was 4.04 ± 0.52 cm (range 2.7-5.7 cm). The Pearson's correlation coefficient (r) between UD and ND was 0.935 (95% confidence interval: 0.72-0.92, r 2 = 0.874, P study demonstrates a good correlation between UD and ND and shows that the preprocedural US scan in transverse plane provides accurate needle entry site with a high success rate in single attempt for lumbar epidurals in patients with a BMI <30 kg/m 2 .

  4. Office-based ultrasound screening for abdominal aortic aneurysm.

    Science.gov (United States)

    Blois, Beau

    2012-03-01

    To assess the efficacy of an office-based, family physician–administered ultrasound examination to screen for abdominal aortic aneurysm (AAA). A prospective observational study. Consecutive patients were approached by nonphysician staff. Rural family physician offices in Grand Forks and Revelstoke, BC. The Canadian Society for Vascular Surgery screening recommendations for AAA were used to help select patients who were at risk of AAA. All men 65 years of age or older were included. Women 65 years of age or older were included if they were current smokers or had diabetes, hypertension, a history of coronary artery disease, or a family history of AAA. A focused “quick screen”, which measured the maximal diameter of the abdominal aorta using point-of-care ultrasound technology, was performed in the office by a resident physician trained in emergency ultrasonography. Each patient was then booked for a criterion standard scan (i.e., a conventional abdominal ultrasound scan performed by a technician and interpreted by a radiologist). The maximal abdominal aortic diameter measured by ultrasound in the office was compared with that measured by the criterion standard method. The time to screen each patient was recorded. Forty-five patients were included in data analysis; 62% of participants were men. The mean age was 73 years. The mean pairwise difference between the office-based ultrasound scan and the criterion standard scan was not statistically significant. The mean absolute difference between the 2 scans was 0.20 cm (95% CI 0.15 to 0.25 cm). Correlation between the scans was 0.81. The office-based ultrasound scan had both a sensitivity and a specificity of 100%. The mean time to screen each patient was 212 seconds (95% CI 194 to 230 seconds). Abdominal aortic aneurysm screening can be safely performed in the office by family physicians who are trained to use point-of- care ultrasound technology. The screening test can be completed within the time constraints of a

  5. Establishing the accuracy and acceptability of abdominal ultrasound to define the foetal head position in the second stage of labour: a validation study.

    LENUS (Irish Health Repository)

    Ramphul, Meenakshi

    2012-09-01

    To compare the diagnosis of the foetal head position in the second stage of labour by ultrasound scan performed by a novice sonographer and by clinical assessment, to that of an expert sonographer (gold standard); and to evaluate the acceptability of ultrasound in the second stage of labour to women and clinicians.

  6. Point of Care Ultrasound

    DEFF Research Database (Denmark)

    Dietrich, Christoph F; Goudie, Adrian; Chiorean, Liliana

    2017-01-01

    Over the last decade, the use of portable ultrasound scanners has enhanced the concept of point of care ultrasound (PoC-US), namely, "ultrasound performed at the bedside and interpreted directly by the treating clinician." PoC-US is not a replacement for comprehensive ultrasound, but rather allows...... and critical care medicine, cardiology, anesthesiology, rheumatology, obstetrics, neonatology, gynecology, gastroenterology and many other applications. In the future, PoC-US will be more diverse than ever and be included in medical student training....

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page This page was reviewed on ... Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding ... Images related to Ultrasound - Pelvis Sponsored by Please ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  9. [Role of ultrasound in elective abortions].

    Science.gov (United States)

    Wylomanski, S; Winer, N

    2016-12-01

    Ultrasound plays a fundamental role in the management of elective abortions. Although it can improve the quality of post-abortion care, it must not be an obstacle to abortion access. We thus studied the role of ultrasound in pregnancy dating and possible alternatives and analyzed the literature to determine the role of ultrasound in post-abortion follow-up. During an ultrasound scan, the date of conception is estimated by measurement of the crown-rump length (CRL), defined by Robinson, or of the biparietal diameter (BPD), as defined by the French Center for Fetal Ultrasound (CFEF) after 11 weeks of gestation (Robinson and CFEF curves) (grade B). Updated curves have been developed in the INTERGROWTH study. In the context of abortion, the literature recommends the application of a safety margin of 5 days, especially when the CRL and/or BPD measurement indicates a term close to 14 weeks (that is equal or below 80 and 27mm, respectively) (best practice agreement). Accordingly, with the ultrasound measurement reliable to±5 days when its performance meets the relevant criteria, an abortion can take place when the CRL measurement is less than 90mm or the BPD less than 30mm (INTERGROWTH curves) (best practice agreement). While a dating ultrasound should be encouraged, its absence is not an obstacle to scheduling an abortion for women who report that they know the date of their last menstrual period and/or of the at-risk sexual relations and for whom a clinical examination by a healthcare professional is possible (best practice agreement). In cases of intrauterine pregnancy of uncertain viability or of a pregnancy of unknown location, without any particular symptoms, the patient must be able to have a transvaginal ultrasound to increase the precision of the diagnosis (grade B). Various reviews of the literature on post-abortion follow-up indicate that the routine use of ultrasound during instrumental abortions should be avoided (best practice agreement). If it becomes

  10. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: A randomised controlled trial.

    Science.gov (United States)

    Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I

    2017-03-01

    Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or percentage of perfect

  11. An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging.

    Science.gov (United States)

    Matrone, Giulia; Ramalli, Alessandro; Savoia, Alessandro Stuart; Quaglia, Fabio; Castellazzi, Gloria; Morbini, Patrizia; Piastra, Marco

    2017-09-24

    The possibility to perform an early and repeatable assessment of imaging performance is fundamental in the design and development process of new ultrasound (US) probes. Particularly, a more realistic analysis with application-specific imaging targets can be extremely valuable to assess the expected performance of US probes in their potential clinical field of application. The experimental protocol presented in this work was purposely designed to provide an application-specific assessment procedure for newly-developed US probe prototypes based on Capacitive Micromachined Ultrasonic Transducer (CMUT) technology in relation to brain imaging. The protocol combines the use of a bovine brain fixed in formalin as the imaging target, which ensures both realism and repeatability of the described procedures, and of neuronavigation techniques borrowed from neurosurgery. The US probe is in fact connected to a motion tracking system which acquires position data and enables the superposition of US images to reference Magnetic Resonance (MR) images of the brain. This provides a means for human experts to perform a visual qualitative assessment of the US probe imaging performance and to compare acquisitions made with different probes. Moreover, the protocol relies on the use of a complete and open research and development system for US image acquisition, i.e. the Ultrasound Advanced Open Platform (ULA-OP) scanner. The manuscript describes in detail the instruments and procedures involved in the protocol, in particular for the calibration, image acquisition and registration of US and MR images. The obtained results prove the effectiveness of the overall protocol presented, which is entirely open (within the limits of the instrumentation involved), repeatable, and covers the entire set of acquisition and processing activities for US images.

  12. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... video display screen and a transducer that is used to do the scanning. The transducer is a ... the body. The principles are similar to sonar used by boats and submarines. The ultrasound image is ...

  13. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  14. Ultrasound of the Thyroid Gland

    Science.gov (United States)

    ... type your comment or suggestion into the following text box: Comment: E-mail: Area code: Phone no: ... Related Articles and Media Head and Neck Cancer Treatment Thyroid Scan and Uptake Ultrasound-Guided ...

  15. First performance results of two novel spectroradiometers developed for fast scanning of solar spectra UV irradiance

    Science.gov (United States)

    Feister, Uwe; Kaifel, Anton K.; Grewe, Rolf-Dieter; Kaptur, Jasmine; Reutter, Oliver; Wohlfart, Michael; Gericke, Klaus

    2003-11-01

    Two recently developed different types of fast spectroradiometers measuring solar UV irradiance have been compared in a field campaign: i) the UV spectroradiometer on filter model basis (UV-SPRAFIMO) and ii) the modified version of the spectroradiometer SPECTRO 320D by Instrument Systems. The all-weather UV-SPRAFIMO instrument combines a UV filter radiometer with 5 narrow-band (FBHM ~ 2.0 to 2.5 nm) filters centered within +/- 0.01 nm at 303.5, 309.0, 314.5, 327.0 and 387.0 nm, and an advanced neural network-based model. It allows up to 5 measurements per second to be taken that are averaged within time intervals between 5 and 30 s. The neural networks model that is embedded in the PC-based processing software converts the 5 measured irradiances into a full spectrum from 280 to 450 nm at small wavelength steps (>= 0.05 nm). These spectra can be convoluted with user-defined slit function and integrated to broad-band and action-spectra-weighted irradiance values. Users can access the data stored in the internal data logger by a serial RS232 interface or by a modem and display them on a PC-based Graphical User Interface. The spectroradiometer SPECTRO320D consists of a grating double monochromator with a cooled (-20°C) PMT receiver. The modified instrument version run by DWD uses a Schreder type cosine diffuser that directs the solar global irradiance via quartz fiber optics onto the spectroradiometer's entrance slit. The spectroradiometer used at the campaign was installed in a thermostatted (22 +/- 0.02)°C aluminum box. The modified instrument version performs a spectral scan over the whole UV region in two subsequent parts, with a lower speed in the UV-B than in the UV-A to account for the exponential changes of solar irradiance with increasing wavelengths in the UV-B and for the almost linear change in the UV-A region. In the configuration applied in the comparison, i.e. wavelength steps of 0.2 nm within the scan range from 290 nm to 450 nm, the resulting scan

  16. Bedside Ultrasound in the Emergency Department to Detect Hydronephrosis for the Evaluation of Suspected Ureteric Colic.

    Science.gov (United States)

    Shrestha, R; Shakya, R M; Khan A, A

    2016-01-01

    Background Renal colic is a common emergency department presentation. Hydronephrosis is indirect sign of urinary obstruction which may be due to obstructing ureteric calculus and can be detected easily by bedside ultrasound with minimal training. Objective To compare the accuracy of detection of hydronephrosis performed by the emergency physician with that of radiologist's in suspected renal colic cases. Method This was a prospective observational study performed over a period of 6 months. Patients >8 years with provisional diagnosis of renal colic with both the bedside ultrasound and the formal ultrasound performed were included. Presence of hydronephrosis in both ultrasounds and size and location of ureteric stone if present in formal ultrasound was recorded. The accuracy of the emergency physician detection of hydronephrosis was determined using the scan reported by the radiologists as the "gold standard" as computed tomography was unavailable. Statistical analysis was executed using SPSS 17.0. Result Among the 111 included patients, 56.7% had ureteric stone detected in formal ultrasound. The overall sensitivity, specificity, positive predictive value and negative predictive value of bedside ultrasound performed by emergency physician for detection of hydronephrosis with that of formal ultrasound performed by radiologist was 90.8%., 78.3%, 85.5% and 85.7% respectively. Bedside ultrasound and formal ultrasound both detected hydronephrosis more often in patients with larger stones and the difference was statistically significant (p=.000). Conclusion Bedside ultrasound can be potentially used as an important tool in detecting clinically significant hydronephrosis in emergency to evaluate suspected ureteric colic. Focused training in ultrasound could greatly improve the emergency management of these patients.

  17. Design and performance of a beetle-type double-tip scanning tunneling microscope

    International Nuclear Information System (INIS)

    Jaschinsky, Philipp; Coenen, Peter; Pirug, Gerhard; Voigtlaender, Bert

    2006-01-01

    A combination of a double-tip scanning tunneling microscope with a scanning electron microscope in ultrahigh vacuum environment is presented. The compact beetle-type design made it possible to integrate two independently driven scanning tunneling microscopes in a small space. Moreover, an additional level for coarse movement allows the decoupling of the translation and approach of the tunneling tip. The position of the two tips can be controlled from the millimeter scale down to 50 nm with the help of an add-on electron microscope. The instrument is capable of atomic resolution imaging with each tip

  18. Emergency Department Ultrasound Is not a Sensitive Detector of Solid Organ Injury

    Directory of Open Access Journals (Sweden)

    Kendall, John L

    2009-02-01

    Full Text Available Objective: To estimate the sensitivity and specificity of emergency department (ED ultrasound for the detection of solid organ injury following blunt abdominal trauma.Methods: A prospective cohort study performed in the ED of an urban Level I trauma center on patients who sustained blunt abdominal trauma. Following initial standard trauma evaluation, patients underwent a secondary ultrasound examination performed specifically to identify injury to the liver or spleen, followed by computed tomography (CT scan of the abdomen. Ultrasound examinations were performed by emergency medicine residents or attending physicians experienced in the use of ultrasound for detecting hemoperitoneum. Ultrasonographers prospectively determined the presence or absence of liver or spleen injury. CT findings were used as the criterion standard to evaluate the ultrasound results.Results: From July 1998 through June 1999, 152 patients underwent secondary ultrasound examination and CT. Of the 152 patients, nine (6% had liver injuries and 10 (7% had spleen injuries. Ultrasound correctly detected only one of the liver injuries for a sensitivity of 11% (95% CI: 0%-48% and a specificity of 98% (95% CI: 94%-100%. Ultrasound correctly detected eight spleen injuries for a sensitivity of 80% (95% CI: 44%-98% and a specificity of 99% (95% CI: 95%-100%.Conclusion: Emergency ultrasound is not sensitive or specific for detecting liver or spleen injuries following blunt abdominal trauma.[WestJEM. 2009;10:1-5.

  19. Vascular ultrasound.

    Science.gov (United States)

    Pilcher, D B; Ricci, M A

    1998-04-01

    Surgeon-interpreted diagnostic ultrasound has become the preferred screening test and often the definitive test for the diagnosis of arterial stenosis, aneurysm, and venous thrombosis. As a modality for surveillance, its noninvasive quality makes it particularly appealing as the test of choice to screen patients for abdominal aortic aneurysms or to perform follow-up examinations on those patients with a carotid endartectomy or in situ bypass grafts. The increasing reliance on intraoperative duplex imaging of vascular procedures demands that the surgeon learn the skills to perform the studies without a technologist or radiologist to interpret the examination.

  20. Single-photon compressive imaging with some performance benefits over raster scanning

    International Nuclear Information System (INIS)

    Yu, Wen-Kai; Liu, Xue-Feng; Yao, Xu-Ri; Wang, Chao; Zhai, Guang-Jie; Zhao, Qing

    2014-01-01

    A single-photon imaging system based on compressed sensing has been developed to image objects under ultra-low illumination. With this system, we have successfully realized imaging at the single-photon level with a single-pixel avalanche photodiode without point-by-point raster scanning. From analysis of the signal-to-noise ratio in the measurement we find that our system has much higher sensitivity than conventional ones based on point-by-point raster scanning, while the measurement time is also reduced. - Highlights: • We design a single photon imaging system with compressed sensing. • A single point avalanche photodiode is used without raster scanning. • The Poisson shot noise in the measurement is analyzed. • The sensitivity of our system is proved to be higher than that of raster scanning

  1. Hand-carried ultrasound performed at bedside in cardiology inpatient setting – a comparative study with comprehensive echocardiography

    Directory of Open Access Journals (Sweden)

    Ramires Jose F

    2004-11-01

    Full Text Available Abstract Background Hand-carried ultrasound (HCU devices have been demonstrated to improve the diagnosis of cardiac diseases over physical examination, and have the potential to broaden the versatility in ultrasound application. The role of these devices in the assessment of hospitalized patients is not completely established. In this study we sought to perform a direct comparison between bedside evaluation using HCU and comprehensive echocardiography (CE, in cardiology inpatient setting. Methods We studied 44 consecutive patients (mean age 54 ± 18 years, 25 men who underwent bedside echocardiography using HCU and CE. HCU was performed by a cardiologist with level-2 training in the performance and interpretation of echocardiography, using two-dimensional imaging, color Doppler, and simple calliper measurements. CE was performed by an experienced echocardiographer (level-3 training and considered as the gold standard. Results There were no significant differences in cardiac chamber dimensions and left ventricular ejection fraction determined by the two techniques. The agreement between HCU and CE for the detection of segmental wall motion abnormalities was 83% (Kappa = 0.58. There was good agreement for detecting significant mitral valve regurgitation (Kappa = 0.85, aortic regurgitation (kappa = 0.89, and tricuspid regurgitation (Kappa = 0.74. A complete evaluation of patients with stenotic and prosthetic dysfunctional valves, as well as pulmonary hypertension, was not possible using HCU due to its technical limitations in determining hemodynamic parameters. Conclusion Bedside evaluation using HCU is helpful for assessing cardiac chamber dimensions, left ventricular global and segmental function, and significant valvular regurgitation. However, it has limitations regarding hemodynamic assessment, an important issue in the cardiology inpatient setting.

  2. Tribological Performance of Ni3Al Matrix Composites Synthesized by Laser Melt Deposition Under Different Scanning Velocities

    Science.gov (United States)

    Huang, Yuchun; Shi, Xiaoliang; Liu, Xiyao; Yan, Zhao; Deng, Xiaobin

    2018-02-01

    In order to study the effect of scanning velocity on the microstructure and tribological properties of Ni3Al matrix composites containing graphene nanoplatelets (NGs), a series of NG samples are successfully synthesized by laser melt deposition under the various scanning velocities from 300 to 500 mm s-1. The sliding friction tests of NG against GCr15 steel balls are carried out under 10 N and 0.2 m s-1 at room temperature. The microstructures, tribological properties and wear mechanisms of the NG samples are analyzed. The results show that the scanning velocity can be optimized to effectively control the surface hardness and relative density, as well as tribological performance of NG. The NG sample synthesized under scanning velocity of 450 mm s-1 has a dense and fine microstructure as well as excellent properties such as higher relative density (98.6%), lower friction coefficient (0.23) and wear rate (5.5 × 10-6 mm3 N-1 m-1). The lower substrate layer with dense and stable structure plays an important role in supporting the upper glaze layer with rich graphene and oxides, as well as nanocrystalline structure, which contributes to the excellent friction-reducing and wear resistance performances of NG. The research results could be used to guide the selection of suitable scanning velocity and study the wear mechanisms of NG for having excellent tribological performance.

  3. Quality control culture of diagnostic ultrasound parameters

    International Nuclear Information System (INIS)

    Andam, A.A.B; Addison, E.C.K.; Aggry-Smith, S.; Nani, E.K.

    2003-01-01

    A phantom, consisting of two phases, has been designed and constructed to mimic the human body. The phase one phantom was designed to mimic a a surface lesion in the human body and the phase two phantom designed to mimic a section of the whole body. Ultrasound scans of the phantom were acquired for various material in the phantom at six hospitals in Kumasi, Ghana. A linear array transducer with parallel beams having a convex probe and a 3.5 MHz ultrasound frequency were used to carry out the experiment. It was observed that the depth of penetration of ultrasound, which constitutes the maximum depth of visualization or sensitivity, is determined by the frequency of the transducer, the attenuation of the medium being imaged and the system settings. Uniformity and linearity of the machines investigated were found to be within clinically acceptable standards. Spatial resolution, comprising axial and lateral resolutions, was observed to be satisfactory for the machines tested. It was observed that lateral resolution improved with the narrowing of the beam width. The ultrasound scanners at the selected hospitals were found to be operating at the expected level of performance. This work highlights the importance of putting in place a locally based mechanism for quality control of diagnostic ultrasound machines (author)

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... is Abdominal Ultrasound Imaging? What are some common uses of the procedure? How should we prepare for an ultrasound exam? What does the ultrasound equipment look like? How does the procedure work? How is the procedure performed? What will my ...

  5. Hand ultrasound: a high-fidelity simulation of lung sliding.

    Science.gov (United States)

    Shokoohi, Hamid; Boniface, Keith

    2012-09-01

    Simulation training has been effectively used to integrate didactic knowledge and technical skills in emergency and critical care medicine. In this article, we introduce a novel model of simulating lung ultrasound and the features of lung sliding and pneumothorax by performing a hand ultrasound. The simulation model involves scanning the palmar aspect of the hand to create normal lung sliding in varying modes of scanning and to mimic ultrasound features of pneumothorax, including "stratosphere/barcode sign" and "lung point." The simple, reproducible, and readily available simulation model we describe demonstrates a high-fidelity simulation surrogate that can be used to rapidly illustrate the signs of normal and abnormal lung sliding at the bedside. © 2012 by the Society for Academic Emergency Medicine.

  6. JPSS-1 VIIRS Pre-Launch Response Versus Scan Angle Testing and Performance

    Science.gov (United States)

    Moyer, David; McIntire, Jeff; Oudrari, Hassan; McCarthy, James; Xiong, Xiaoxiong; De Luccia, Frank

    2016-01-01

    The Visible Infrared Imaging Radiometer Suite (VIIRS) instruments on-board both the Suomi National Polar-orbiting Partnership (S-NPP) and the first Joint Polar Satellite System (JPSS-1) spacecraft, with launch dates of October 2011 and December 2016 respectively, are cross-track scanners with an angular swath of +/-56.06 deg. A four-mirror Rotating Telescope Assembly (RTA) is used for scanning combined with a Half Angle Mirror (HAM) that directs light exiting from the RTA into the aft-optics. It has 14 Reflective Solar Bands (RSBs), seven Thermal Emissive Bands (TEBs) and a panchromatic Day Night Band (DNB). There are three internal calibration targets, the Solar Diffuser, the BlackBody and the Space View, that have fixed scan angles within the internal cavity of VIIRS. VIIRS has calibration requirements of 2% on RSB reflectance and as tight as 0.4% on TEB radiance that requires the sensor's gain change across the scan or Response Versus Scan angle (RVS) to be well quantified. A flow down of the top level calibration requirements put constraints on the characterization of the RVS to 0.2%-0.3% but there are no specified limitations on the magnitude of response change across scan. The RVS change across scan angle can vary significantly between bands with the RSBs having smaller changes of approximately 2% and some TEBs having approximately 10% variation. Within aband, the RVS has both detector and HAM side dependencies that vary across scan. Errors in the RVS characterization will contribute to image banding and striping artifacts if their magnitudes are above the noise level of the detectors. The RVS was characterized pre-launch for both S-NPP and JPSS-1 VIIRS and a comparison of the RVS curves between these two sensors will be discussed.

  7. Sonomammography: An atlas of comparative breast ultrasound

    International Nuclear Information System (INIS)

    Guyer, B.P.; Dewsbury, K.C.

    1987-01-01

    This atlas of breast ultrasound is extensively illustrated and provides a short analytical text before each group of pathologies. Although based on B-scan techniques, there are numerous comparisons with sector scans and linear array scans. X-ray mammography and breast ultrasound is analyzed, based upon 2000 sonomammograms, showing how a more accurate pre-operation assessment can be made, and how unnecessary surgery can be reduced. Major features of this atlas include a detailed analysis of the appearances of breast lesions, extensive illustrations of the various pathologies (generally confirmed histologically), a close comparison of ultrasound with x-ray mammography, and illustrations of lesions by different ultrasound techniques

  8. Diagnostic significance of ultrasound in dermatology

    OpenAIRE

    Stojanović Slobodan; Poljački Mirjana N.; Roš Tatjana

    2002-01-01

    Introduction Utilization of 20 MHz ultrasound probes provided application of ultrasound in dermatology - dermatosonography. As a diagnostic tool, ultrasound was first registered in the early fifties of the past century. Great progress of dermatosonography occurred in the mid-nineties with introduction of the first 20 MHz scanner. Methods of ultrasonography in dermatology Several methods of ultrasonography have been developed: method A, method B, scanning C method and Doppler ultrasound. They ...

  9. [Ultrasound scanning of the distraction regenerate in case of multilocus elongation of the fragments in patients with defects of long bones].

    Science.gov (United States)

    Menshikova, T I; Borzunov, D Iu; Dolganova, T I

    2014-01-01

    It was done ultrasound examination of distraction regenerates in patients with defect of bone tissue. The first group included 4 patients who had the size of congenital bone tissue defect 15.8±8.1 cm; the second group (3 patients) included posttraumatic defects with defect size 11.75±3.6 cm; the third group (4 patients) included posttraumatic defects with defect size 11±5.3 cm. It was discovered the particularities of distraction regenerate structural condition in case of low level of reparative osteogenesis. In the first group "ischemic" regenerate was characterized by slow formation of bone trabecules. In the second group "ischemic" regenerate had one or two hypo-echogenic cystic-like formations in the intermediate regenerate area. All patients of the third group had organotypic remodeling of the regenerate according to terms of distraction and fixation.

  10. Neuromuscular ultrasound of cranial nerves.

    Science.gov (United States)

    Tawfik, Eman A; Walker, Francis O; Cartwright, Michael S

    2015-04-01

    Ultrasound of cranial nerves is a novel subdomain of neuromuscular ultrasound (NMUS) which may provide additional value in the assessment of cranial nerves in different neuromuscular disorders. Whilst NMUS of peripheral nerves has been studied, NMUS of cranial nerves is considered in its initial stage of research, thus, there is a need to summarize the research results achieved to date. Detailed scanning protocols, which assist in mastery of the techniques, are briefly mentioned in the few reference textbooks available in the field. This review article focuses on ultrasound scanning techniques of the 4 accessible cranial nerves: optic, facial, vagus and spinal accessory nerves. The relevant literatures and potential future applications are discussed.

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ... of page What are the benefits vs. risks? Benefits Most ultrasound scanning is ... with your doctor, the medical facility staff and/or your insurance provider to get a better understanding of the ...

  12. SCaN Network Ground Station Receiver Performance for Future Service Support

    Science.gov (United States)

    Estabrook, Polly; Lee, Dennis; Cheng, Michael; Lau, Chi-Wung

    2012-01-01

    Objectives: Examine the impact of providing the newly standardized CCSDS Low Density Parity Check (LDPC) codes to the SCaN return data service on the SCaN SN and DSN ground stations receivers: SN Current Receiver: Integrated Receiver (IR). DSN Current Receiver: Downlink Telemetry and Tracking (DTT) Receiver. Early Commercial-Off-The-Shelf (COTS) prototype of the SN User Service Subsystem Component Replacement (USS CR) Narrow Band Receiver. Motivate discussion of general issues of ground station hardware design to enable simple and cheap modifications for support of future services.

  13. Comparison of the development of performance skills in ultrasound-guided regional anesthesia simulations with different phantom models.

    Science.gov (United States)

    Liu, Yang; Glass, Nancy L; Glover, Chris D; Power, Robert W; Watcha, Mehernoor F

    2013-12-01

    Ultrasound-guided regional anesthesia (UGRA) skills are traditionally obtained by supervised performance on patients, but practice on phantom models improves success. Currently available models are expensive or use perishable products, for example, olive-in-chicken breasts (OCB). We constructed 2 inexpensive phantom (transparent and opaque) models with readily available nonperishable products and compared the process of learning UGRA skills by novice practitioners on these models with the OCB model. Three experts first established criteria for a satisfactory completion of the simulated UGRA task in the 3 models. Thirty-six novice trainees (simulations was accomplished. The number of errors, needle passes, and time for task completion per attempt progressively decreased in all 3 groups. However, failure to identify the target and to visualize the needle on the ultrasound image occurred more frequently with the OCB model. The time to complete simulator training was shortest with the transparent model, owing to shorter target identification times. However, trainees were less likely to agree strongly that this model was realistic for teaching UGRA skills. Training on inexpensive synthetic simulation models with no perishable products permits learning of UGRA skills by novices. The OCB model has disadvantages of containing potentially infective material, requires refrigeration, cannot be used after multiple needle punctures, and is associated with more failures during simulated UGRA. Direct visualization of the target in the transparent model allows the trainee to focus on needle insertion skills, but the opaque model may be more realistic for learning target identification skills required when UGRA is performed on real patients in the operating room.

  14. Solubilization of bovine gelatin using power ultrasound: gelation without heating.

    Science.gov (United States)

    Farahnaky, Asgar; Zendeboodi, Fatemeh; Azizi, Rezvan; Mesbahi, Gholamreza; Majzoobi, Mahsa

    2017-04-01

    The aim of this study was to investigate the efficacy of power ultrasound without using any heating stage in solubilizeing gelatin dispersions, and to characterize the mechanical and microstructural properties of the resulting gels using texture analysis and scanning electron microscopy, respectively. Usually to prepare a gel from gelatin, a primary heating stage of at about 40C or above is required to solubilize gelatin macromolecules. In this study solubilizing gelatin dispersions using power ultrasound without any heating was successfully performed. For solubilising gelatin, an ultrasound equipment with a frequency of 20 kHz, amplitude of 100% and power range of 50-150 W was used. Aqueous gelatin dispersions (4% w/v) were subjected to ultrasound for different times (40-240 s) at a constant temperature of 13C. Applying ultrasound to gelatin dispersions caused increases in water absorption and water solubility of the hydrocolloid. The textural parameters of the resulting gelatin gels, increased with increasing time and power of ultrasound. Moreover, a generalized Maxwell model with three elements was used for calculating relaxation times of the gels. The microstructural observations by SEM showed that the structural cohesiveness of the gels increased by increasing ultrasonication time. Ultrasound-assisted solubilization of gelatin can have emerging implications for industrial uses in pharmaceuticals, food and non-food systems. Usually to prepare a gel from gelatin, a primary heating stage of at about 40C or above is required to solubilize gelatin macromolecules. Therefore, the use of gelatin as a hydrocolloid in food processings or pharmaceutical formulations which lack a heating step has been a technological and practical challenge. In this study solubilizing gelatin dispersions using power ultrasound without any heating was successfully performed. Ultrasound-assisted solubilisation of gelatin can have emerging implications for industrial uses in pharmaceuticals

  15. Optimalisatie performance van vleeskuikens bij mobiel voer- en drinksysteem (scanFeeder) op praktijkbedrijf

    NARCIS (Netherlands)

    Harn, van J.; Veldkamp, T.

    2007-01-01

    Het gebruik van de Ridder ScanFeeder, een mobiel voer- en drinksysteem met strooiselbeluchting voor vleeskuikens, geeft een betere strooiselkwaliteit (ruller en droger strooisel) en minder voetzoolaandoeningen. De technische resultaten bij dit systeem blijven echter achter bij die van een

  16. Performance analysis of a hybrid fingerprint extracted from optical coherence tomography fingertip scans

    CSIR Research Space (South Africa)

    Darlow, Luke N

    2016-06-01

    Full Text Available The Hybrid fingerprint is a local-quality-specific blend of the surface and internal fingerprints, extracted from optical coherence tomography scans. Owing to its origin, and the manner in which it is obtained, the Hybrid fingerprint is a high...

  17. Pilot performance: assessing how scan patterns & navigational assessments vary by flight expertise.

    Science.gov (United States)

    Yang, Ji Hyun; Kennedy, Quinn; Sullivan, Joseph; Fricker, Ronald D

    2013-02-01

    Helicopter overland navigation is a cognitively complex task that requires continuous monitoring of system and environmental parameters and many hours of training to master. This study investigated the effect of expertise on pilots' gaze measurements, navigation accuracy, and subjective assessment of their navigation accuracy in overland navigation on easy and difficult routes. A simulated overland task was completed by 12 military officers who ranged in flight experience as measured by total flight hours (TFH). They first studied a map of a route that included both easy and difficult route sections, and then had to 'fly' this simulated route in a fixed-base helicopter simulator. They also completed pre-task estimations and post-task assessments of the navigational difficulty of the transit to each waypoint in the route. Their scan pattern was tracked via eye tracking systems, which captured both the subject's out-the-window (OTW) and topographical map scan data. TFH was not associated with navigation accuracy or root mean square (RMS) error for any route section. For the easy routes, experts spent less time scanning out the window (p = 0.61) and had shorter OTW dwell (p = -0.66). For the difficult routes, experts appeared to slow down their scan by spending as much time scanning out the window as the novices while also having fewer Map fixations (p = -0.65) and shorter OTW dwell (p = -0.69). However, TFH was not significantly correlated with more accurate estimates of route difficulty. This study found that TFH did not predict navigation accuracy or subjective assessment, but was correlated with some gaze parameters.

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ... pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic organs early ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... size, shape and consistency (whether the object is solid or filled with fluid). In medicine, ultrasound is ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... pictures of a man’s prostate gland and to help diagnose symptoms such as difficulty urinating or an ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also help identify: ... fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... There are three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams ... are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is used to evaluate the: bladder seminal vesicles prostate Transrectal ultrasound, a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ultrasound transducer into ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding ... questions or for a referral to a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ... abnormal masses, such as tumors. In an ultrasound examination, a transducer both sends the sound waves into ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ... structure and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ... sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... help to distract the child and make the time pass quickly. The ultrasound exam room may have ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ... bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the prostate gland because ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Imaging? Ultrasound waves are disrupted by air or gas; therefore ultrasound is not an ideal imaging technique ... page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Because ultrasound provides real-time images, it also can be used to guide procedures such as needle ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Ultrasound exams in which the transducer ... in the sperm or urine following the procedure. After an ultrasound examination, you should be able to ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries ... abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with infertility. In ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  2. Obstetrical Ultrasound

    Science.gov (United States)

    ... heartbeat can be seen as an ongoing ultrasound movie. Ultrasound devices also use Doppler, a special application ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... menstrual problems Ultrasound exams also help identify: palpable masses such as ovarian cysts and uterine fibroids ovarian ... In children, pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and development of an embryo or fetus during pregnancy. See the Obstetrical Ultrasound page for more information . ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... most ultrasound exams, you will be positioned lying face-up on an examination table that can be ... region of the prostate. A biopsy will add time to the procedure. If a Doppler ultrasound study ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  10. Lung Ultrasound for Diagnosing Pneumothorax in the Critically Ill Neonate.

    Science.gov (United States)

    Raimondi, Francesco; Rodriguez Fanjul, Javier; Aversa, Salvatore; Chirico, Gaetano; Yousef, Nadya; De Luca, Daniele; Corsini, Iuri; Dani, Carlo; Grappone, Lidia; Orfeo, Luigi; Migliaro, Fiorella; Vallone, Gianfranco; Capasso, Letizia

    2016-08-01

    To evaluate the accuracy of lung ultrasound for the diagnosis of pneumothorax in the sudden decompensating patient. In an international, prospective study, sudden decompensation was defined as a prolonged significant desaturation (oxygen saturation pneumothorax was detected in 26 (62%). Lung ultrasound accuracy in diagnosing pneumothorax was as follows: sensitivity 100%, specificity 100%, positive predictive value 100%, and negative predictive value 100%. Clinical evaluation of pneumothorax showed sensitivity 84%, specificity 56%, positive predictive value 76%, and negative predictive value 69%. After sudden decompensation, a lung ultrasound scan was performed in an average time of 5.3 ± 5.6 minutes vs 19 ± 11.7 minutes required for a chest radiography. Emergency drainage was performed after an ultrasound scan but before radiography in 9 cases. Lung ultrasound shows high accuracy in detecting pneumothorax in the critical infant, outperforming clinical evaluation and reducing time to imaging diagnosis and drainage. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Ultrasound Imaging. Chapter 13

    Energy Technology Data Exchange (ETDEWEB)

    Lacefield, J. C. [University of Western Ontario, London (Canada)

    2014-09-15

    In the conventional method of ultrasonography, images are acquired in reflection, or pulse echo, mode. An array of small piezoelectric elements transmits a focused pulse along a specified line of sight known as a scan line. Echoes returning from the tissue are received by the same array, focused via the delay-and-sum beam forming process reviewed in Section 13.2, and demodulated to obtain the magnitude, or envelope, of the echo signal. The scanner measures the arrival time of the echoes relative to the time the pulse was transmitted and maps the arrival time to the distance from the array, using an assumed speed of sound. The earliest ultrasound systems would display the result of a single pulse acquisition in 1-D A-mode (amplitude mode) format by plotting echo magnitude as a function of distance. A 2-D or 3-D B-mode (brightness mode) image is acquired by performing a large number of pulse echo acquisitions, incrementally increasing the scan line direction between each pulse echo operation, to sweep out a 2-D or 3-D field of view (FOV). The term B-mode imaging reflects the fact that the echo magnitude from each point in the FOV is mapped to the grey level, or brightness, of the corresponding pixel in the image.

  12. A Formalized Three-Year Emergency Medicine Residency Ultrasound Education Curriculum

    Directory of Open Access Journals (Sweden)

    Andrew King

    2016-09-01

    Full Text Available Audience and type of curriculum: The Ohio State University Wexner Medical Center Emergency Medicine Residency Program Ultrasound Education Curriculum is a three-year curriculum for PGY-1 to PGY-3 learners. Introduction/Background: Each year of the three-year The Ohio State University Wexner Medical Center Emergency Medicine Ultrasound Curriculum focuses on different aspects of emergency ultrasonography, thereby promoting progressive understanding and utilization of point-of-care ultrasound in medical decision-making during residency training. Ultrasound is an invaluable bedside tool for emergency physicians; this skill must be mastered by resident learners during residency training, and ultrasound competency is a required ACGME milestone.1 The American College of Emergency Physicians (ACEP currently recommends that 11 applications of emergency ultrasound be part of the core skills of an emergency physician.2 This curriculum acknowledges the standards developed by ACEP and the ACGME. Objectives: Learners will 1 know the indications for each the 11 ACEP point-of-care ultrasound (POCUS applications; 2 perform each of the 11 ACEP POCUS applications; 3 integrate POCUS into medical decision-making. Methods: The educational strategies used in this curriculum include: independent, self-directed learning (textbook and literature reading, brief didactic sessions describing indications and technique for each examination, hands-on ultrasound scanning under the direct supervision of ultrasound faculty with real-time feedback, and quality assurance review of ultrasound images. Residents are expected to perform a minimum of 150 ultrasound examinations with associated quality assurance during the course of their residency training. The time requirements, reading material, and ultrasound techniques taught vary depending on the year of training. Length of curriculum: The entirety of the curriculum is three years; however, each year of residency training has

  13. Using low frequency and intensity ultrasound to enhance start-up and operation performance of Anammox process inoculated with the conventional sludge.

    Science.gov (United States)

    Wang, Tao; Zhang, Diandian; Sun, Yating; Zhou, Shanshan; Li, Lin; Shao, Jingjing

    2018-04-01

    A lab-scale ultrasound enhancing Anammox reactor (R1) was established and irradiated once a week by ultrasound with the optimal parameter (frequency of 25 kHz, intensity of 0.2 W cm -2 and exposure time of 3 min) obtained by batch experiments. R1 and the controlled Anammox reactor (R2) without exposure to the ultrasound were operated in parallel. The start-up period of Anammox process (53 days) in R1 was shorter than that (61 days) in R2. The nitrogen loading-enhancing period (day 53-day 135) in R1 was also shorter than that (day 61-day 151) in R2. At the end of the nitrogen loading-enhancing period, NLR (0.76 kg N m -3  d -1 ) and NRR (0.68 kg N m -3  d -1 ) of R1 were both higher than NLR (0.66 kg N m -3  d -1 ) and NRR (0.56 kg N m -3  d -1 ) of R2. Moreover, The stability of Anammox process in R1 was better than that in R2. The results demonstrated that the periodical irradiation of ultrasound enhanced the start-up and operational performance of Anammox reactor. Microbial community analysis indicated that the ultrasound accelerated the microbial succession from some other bacteria to Anammox bacteria so that shorten the start-up period of Anammox process from the conventional activated sludge. It also indicated that the ultrasound strengthened the competitive advantage of Candidatus Kuenenia stuttgartiensis in Anammox bacteria of the mature sludge so as to enhance the nitrogen removal performance of the Anammox reactor under the operation condition of high nitrogen loading. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Sonographic measurement of thyroid gland volume: A comparison of 2D and 3D ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Ying, Michael [Department of Optometry and Radiography, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China)]. E-mail: ormying@polyu.edu.hk; Sin Manhong [Department of Optometry and Radiography, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China); Pang, Shuk-fan [Department of Optometry and Radiography, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China)

    2005-11-01

    Aims: This study was undertaken to investigate the inter-observer reproducibility of 2D and 3D ultrasound in the measurement of thyroid gland volume. The symmetry of thyroid lobes in healthy subjects was also investigated. Materials and methods: The volume of the left and right lobes of the thyroid gland was measured in 20 healthy subjects (10 men and 10 women) using 2D and 3D ultrasound. On 2D ultrasound, the thyroid lobe volume was calculated by ellipsoid equation (volume = {pi}/6 x craniocaudal x mediolateral x anteroposterior dimensions), whereas 3D ultrasound volumetric measurements were performed with a 3D add-on system. In each subject, the thyroid gland was scanned by two operators to investigate inter-observer variability. Results: There was a moderate agreement between 2D and 3D ultrasound in the measurement of thyroid volume (r = 0.77). 3D ultrasound (90%) had a higher inter-observer reproducibility than 2D ultrasound (85%) in the measurements. About 74% of healthy subjects had the right thyroid lobe larger than the left lobe. Conclusion: 3D ultrasound is useful in the measurement of thyroid volume with a higher reproducibility than 2D ultrasound. Asymmetry of thyroid lobes was noted in healthy subjects.

  15. Sonographic measurement of thyroid gland volume: A comparison of 2D and 3D ultrasound

    International Nuclear Information System (INIS)

    Ying, Michael; Sin Manhong; Pang, Shuk-fan

    2005-01-01

    Aims: This study was undertaken to investigate the inter-observer reproducibility of 2D and 3D ultrasound in the measurement of thyroid gland volume. The symmetry of thyroid lobes in healthy subjects was also investigated. Materials and methods: The volume of the left and right lobes of the thyroid gland was measured in 20 healthy subjects (10 men and 10 women) using 2D and 3D ultrasound. On 2D ultrasound, the thyroid lobe volume was calculated by ellipsoid equation (volume = π/6 x craniocaudal x mediolateral x anteroposterior dimensions), whereas 3D ultrasound volumetric measurements were performed with a 3D add-on system. In each subject, the thyroid gland was scanned by two operators to investigate inter-observer variability. Results: There was a moderate agreement between 2D and 3D ultrasound in the measurement of thyroid volume (r = 0.77). 3D ultrasound (90%) had a higher inter-observer reproducibility than 2D ultrasound (85%) in the measurements. About 74% of healthy subjects had the right thyroid lobe larger than the left lobe. Conclusion: 3D ultrasound is useful in the measurement of thyroid volume with a higher reproducibility than 2D ultrasound. Asymmetry of thyroid lobes was noted in healthy subjects

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Pelvic Ultrasound Imaging? Ultrasound waves are ...

  17. Organizations as Information Processing Systems. Environmental Characteristics, Company Performance, and Chief Executive Scanning: An Empirical Study.

    Science.gov (United States)

    1986-04-01

    H. Igor , "Managing Strategic Surprise by Response to Weak Signals," California Management Review, 18, No. 2 (Winter 1975), pp. 21-33. Ansoff , H. Igor ...environment (Hamhrick, 1981). Scanning provides the external intelligence that is used in planning, decision making and strategy formulation ( Ansoff , 1979...discussion. Personal communications are content rich and enable executives to detect weak N. signals ( Ansoff , 1975). Impersonal sources are appropriate

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... is General Ultrasound Imaging? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  19. Performance of hand-held whole-breast ultrasound based on BI-RADS in women with mammographically negative dense breast

    International Nuclear Information System (INIS)

    Youk, Ji Hyun; Kim, Eun-Kyung; Kim, Min Jung; Kwak, Jin Young; Son, Eun Ju

    2011-01-01

    To assess the performance of breast ultrasound based on BI-RADS final assessment categories in women with mammographically negative dense breast. Of 3,820 cases with mammographically negative dense breast and subsequent hand-held bilateral whole-breast ultrasound, a total of 1,507 cases in 1,046 women who had biopsy or at least 2-year follow-up ultrasound constituted the basis of this retrospective study. Cancer rate of each sonographic BI-RADS category was determined and medical audit was performed separately in screening-general, screening-treated, and diagnostic group. A total of 43 cases (2.9%) were confirmed as malignancy. Cancer rate among BI-RADS categories was significantly different (p < 0.0001). Among three groups, the cancer rate was significantly different (p < 0.0001) and the highest in diagnostic group (15.8%, 22 of 139). Abnormal interpretation rate, PPV of biopsy performed, cancer detection rate, and rate of early stage cancer, and the size of invasive cancer were significantly different among three groups and the highest in diagnostic group. Regarding cancer characteristics, the proportion of advanced cancer was the highest in diagnostic group. Breast ultrasound based on BI-RADS as an adjunctive to negative mammography can be useful for predicting malignancy in women with dense breast. (orig.)

  20. USEFUL: Ultrasound Exam for Underlying Lesions Incorporated into Physical Exam

    Directory of Open Access Journals (Sweden)

    Jon Steller

    2014-05-01

    Full Text Available Introduction: The Ultrasound Screening Exam for Underlying Lesions (USEFUL was developed in an attempt to establish a role for bedside ultrasound in the primary and preventive care setting. It is the purpose of our pilot study to determine if students were first capable of performing all of the various scans required of our USEFUL while defining such an ultrasound-assisted physical exam that would supplement the standard hands-on physical exam in the same head-to-toe structure. We also aimed to assess the time needed for an adequate exam and analyze if times improved with repetition and previous ultrasound training. Methods: Medical students with ranging levels of ultrasound training received a 25-minute presentation on our USEFUL followed by a 30-minute hands-on session. Following the hands-on session, the students were asked to perform a timed USEFUL on 2-3 standardized subjects. All images were documented as normal or abnormal with the understanding that an official detailed exam would be performed if an abnormality were to be found. All images were read and deemed adequate by board eligible emergency medicine ultrasound fellows. Results: Twenty-six exams were performed by 9 students. The average time spent by all students per USEFUL was 11 minutes and 19 seconds. Students who had received the University of California, Irvine School of Medicine’s integrated ultrasound curriculum performed the USEFUL significantly faster (p< 0.0025. The time it took to complete the USEFUL ranged from 6 minutes and 32 seconds to 17 minutes, and improvement was seen with each USEFUL performed. The average time to complete the USEFUL on the first standardized patient was 13 minutes and 20 seconds, while 11 minutes and 2 seconds, and 9 minutes and 20 seconds were spent performing the exam on the second and third patient, respectively. Conclusion: Students were able to effectively complete all scans required by the USEFUL in a timely manner. Students who have

  1. Ultrasound-based guidance of intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Fung, Albert Y.C.; Ayyangar, Komanduri M.; Djajaputra, David; Nehru, Ramasamy M.; Enke, Charles A.

    2006-01-01

    In ultrasound-guided intensity-modulated radiation therapy (IMRT) of prostate cancer, ultrasound imaging ascertains the anatomical position of patients during x-ray therapy delivery. The ultrasound transducers are made of piezoelectric ceramics. The same crystal is used for both ultrasound production and reception. Three-dimensional (3D) ultrasound devices capture and correlate series of 2-dimensional (2D) B-mode images. The transducers are often arranged in a convex array for focusing. Lower frequency reaches greater depth, but results in low resolution. For clear image, some gel is usually applied between the probe and the skin contact surface. For prostate positioning, axial and sagittal scans are performed, and the volume contours from computed tomography (CT) planning are superimposed on the ultrasound images obtained before radiation delivery at the linear accelerator. The planning volumes are then overlaid on the ultrasound images and adjusted until they match. The computer automatically deduces the offset necessary to move the patient so that the treatment area is in the correct location. The couch is translated as needed. The currently available commercial equipment can attain a positional accuracy of 1-2 mm. Commercial manufacturer designs differ in the detection of probe coordinates relative to the isocenter. Some use a position-sensing robotic arm, while others have infrared light-emitting diodes or pattern-recognition software with charge-couple-device cameras. Commissioning includes testing of image quality and positional accuracy. Ultrasound is mainly used in prostate positioning. Data for 7825 daily fractions of 234 prostate patients indicated average 3D inter-fractional displacement of about 7.8 mm. There was no perceivable trend of shift over time. Scatter plots showed slight prevalence toward superior-posterior directions. Uncertainties of ultrasound guidance included tissue inhomogeneities, speckle noise, probe pressure, and inter

  2. STEMsalabim: A high-performance computing cluster friendly code for scanning transmission electron microscopy image simulations of thin specimens

    International Nuclear Information System (INIS)

    Oelerich, Jan Oliver; Duschek, Lennart; Belz, Jürgen; Beyer, Andreas; Baranovskii, Sergei D.; Volz, Kerstin

    2017-01-01

    Highlights: • We present STEMsalabim, a modern implementation of the multislice algorithm for simulation of STEM images. • Our package is highly parallelizable on high-performance computing clusters, combining shared and distributed memory architectures. • With STEMsalabim, computationally and memory expensive STEM image simulations can be carried out within reasonable time. - Abstract: We present a new multislice code for the computer simulation of scanning transmission electron microscope (STEM) images based on the frozen lattice approximation. Unlike existing software packages, the code is optimized to perform well on highly parallelized computing clusters, combining distributed and shared memory architectures. This enables efficient calculation of large lateral scanning areas of the specimen within the frozen lattice approximation and fine-grained sweeps of parameter space.

  3. STEMsalabim: A high-performance computing cluster friendly code for scanning transmission electron microscopy image simulations of thin specimens

    Energy Technology Data Exchange (ETDEWEB)

    Oelerich, Jan Oliver, E-mail: jan.oliver.oelerich@physik.uni-marburg.de; Duschek, Lennart; Belz, Jürgen; Beyer, Andreas; Baranovskii, Sergei D.; Volz, Kerstin

    2017-06-15

    Highlights: • We present STEMsalabim, a modern implementation of the multislice algorithm for simulation of STEM images. • Our package is highly parallelizable on high-performance computing clusters, combining shared and distributed memory architectures. • With STEMsalabim, computationally and memory expensive STEM image simulations can be carried out within reasonable time. - Abstract: We present a new multislice code for the computer simulation of scanning transmission electron microscope (STEM) images based on the frozen lattice approximation. Unlike existing software packages, the code is optimized to perform well on highly parallelized computing clusters, combining distributed and shared memory architectures. This enables efficient calculation of large lateral scanning areas of the specimen within the frozen lattice approximation and fine-grained sweeps of parameter space.

  4. A new Krakow scanning nuclear microprobe performance tests and early application experienc

    CERN Document Server

    Lebed, S; Polak, W; Potempa, A W; Stachura, Z; Paszkowski, M

    2001-01-01

    A new scanning nuclear microprobe (MP) with a short-length probe forming system was designed,installed and tested at the 3MV Van de Graaff accelerator in Krakow.The MP resolution of 3.3 mu m was reached for 2.4 MeV proton beam in the high-current mode (>= 100pA).The MP facility provides a local,non-destructive,quantitative elemental microanalysis using a Proton Induced X-ray Emission (PIXE) technique.As example of possible application an analysis of a geological sample containing monazite crystals investigated by PIXE method is presented.

  5. Anthropometry, physical performance, and ultrasound patellar tendon abnormality in elite junior basketball players: a cross-sectional study.

    Science.gov (United States)

    Cook, J L; Kiss, Z S; Khan, K M; Purdam, C R; Webster, K E

    2004-04-01

    Patellar tendinopathy has been reported to be associated with many intrinsic risk factors. Few have been fully investigated. This cross-sectional study examined the anthropometric and physical performance results of elite junior basketball players with normal or abnormal patellar tendons to see if any measures were associated with changes in tendon morphology. Agility, leg strength, endurance, and flexibility were measured in 71 male and 64 female players. A blinded radiologist ultrasonographically examined their patellar tendons and athletes were grouped as having normal or abnormal tendons. One-way ANOVA was used to test for differences in anthropometric and physical performance data for athletes whose tendons were normal or abnormal (unilateral or bilateral tendinopathy) on ultrasound. Results show that females with abnormalities in their tendons had a significantly better vertical jump (50.9+/-6.8 cm) than those with normal tendons (46.1+/-5.4 cm) (p = 0.02). This was not found in males. In males, the mean sit and reach in those with normal tendons (13.2+/-6.7 cm) was greater (ptendinopathy (10.3+/-6.2 cm) or in bilateral tendinopathy (7.8+/-8.3 cm). In females, those with normal tendons (13.3+/-4.8 cm) and bilateral tendinopathy (15.8+/-6.2 cm) were distinctly different from those with unilateral tendinopathy (7.9+/-6.6 cm). Flexibility and vertical jump ability are associated with patellar tendinopathy and the findings warrant consideration when managing young, jumping athletes.

  6. Contrast-enhanced ultrasound features of histologically proven focal nodular hyperplasia: diagnostic performance compared with contrast-enhanced CT

    International Nuclear Information System (INIS)

    Wang, Wei; Chen, Li-Da; Liu, Guang-Jian; Xu, Zuo-Feng; Xie, Xiao-Yan; Wang, Yan; Zhou, Lu-Yao; Lu, Ming-De; Shen, Shun-Li

    2013-01-01

    To investigate and compare contrast-enhanced ultrasound (CEUS) in the characterisation of histologically proven focal nodular hyperplasia (FNH) with contrast-enhanced computed tomography (CECT). CEUS was performed in 85 patients with 85 histologically proven FNHs. Enhancement, centrifugal filling, spoke-wheel arteries, feeding artery and central scarring were reviewed and correlated with lesion size or liver background. Independent factors for predicting FNH from other focal liver lesions (FLLs) were evaluated. Forty-seven FLLs with CECT were randomly selected for comparison of diagnostic performance with CEUS. Centrifugal filling was more common (P = 0.002) and the significant predictor (P = 0.003) in FNHs ≤3 cm. Lesion size or liver background has no significant influence on the detection rate of the spoke-wheel arteries and feeding artery (P > 0.05). Central scarring was found in 42.6 % of FNHs ≥3 cm (P = 0.000). The area under the ROC curve, sensitivity and specificity showed no significant differences between CEUS and CECT (P > 0.05), except that the sensitivity of CEUS was better for reader 1 (P = 0.041). CEUS is valuable in characterising centrifugal filling signs or spoke wheels in small FNHs and should be employed as the first-line imaging technique for diagnosis of FNH. (orig.)

  7. Supplementation of beef cattle grazing Brachiariabrizantha during the dry and rainy seasons: performance and carcass ultrasound prediction

    Directory of Open Access Journals (Sweden)

    Geisi Loures Guerra

    2016-10-01

    Full Text Available The aim of this study was to evaluate the influence of genetic group, sex and level of protein-energy supplementation on the performance and carcass traitsultrasound prediction of weaned calves Nellore and crossbred animals ½ Nellore x ½ Aberdeen Angus. A completely randomized design in a factorial 2x2x2, were used, with two levels of protein-energy supplementation, two sex and two genetic groups. Fifty-six animals were used (28 Nellore and 28 crossbred ½ Nellore x ½ Aberdeen Angus, equally divided between males and females, maintained on grazing Brachiariabrizanthacv. Marandu and evaluated in three experimental periods: period 1 = protein-energy supplementation in the dry season; period 2 = protein-energy supplementation during the rainy season; period 3 = only mineral supplementation. In the dry season, they were supplemented with levels of 0.5 and 1% of body weight (BW and in the rainy season with 0 and 1% BW. Dry matter intake (kg day-1, % BW, g kgBW0.75-1 was estimated. In vivo ultrasound measurements of carcass were: loin eye area (LEA, fat thickness (FT and rump fat thickness (RFT. There was influence of genetic group and protein-energy supplementation levels on average daily gain (ADG of animals in period 1 and 2 (P < 0.05. Sex affected the ADG only in period 2, and the males had 754 gday-1 and females, 582 g day-1. There was no interaction of genetic group x sex x supplementation level. At the end of the experimental period (end of period 3, it was found that male animals and crossbred animals ½ Nellore x ½ Aberdeen Angus had higher ADG (716 and 748 g day-1, respectively. The values of dry matter intake (DMI were influenced by genetic group and sex, in all periods, verifying highest intake in crossbred animals ½ Nellore x ½ Aberdeen Angus, with better feed conversion for crossbred animals. Regarding ultrasound measurements taken on the carcass, the influence of sex on FT and RFT, it was observed, and the males showed higher

  8. Boosting antenatal care attendance and number of hospital deliveries among pregnant women in rural communities: a community initiative in Ghana based on mobile phones applications and portable ultrasound scans.

    Science.gov (United States)

    Amoah, Benjamin; Anto, Evelyn A; Osei, Prince K; Pieterson, Kojo; Crimi, Alessandro

    2016-06-14

    The World Health Organization has recommended at least four antenatal care (ANC) visits and skilled attendants at birth. Most pregnant women in rural communities in low-income countries do not achieve the minimum recommended visits and deliver without skilled attendants. With the aim of increasing number of ANC visits, reducing home deliveries, and supplementing care given by ANC clinics, a proposed system based on low-cost mobile phones and portable ultrasound scan machines was piloted. A sample of 323 pregnant women from four rural communities in the Central Region of Ghana were followed within a 11-month project. In each community, at least one health worker was trained and equipped with a mobile phone to promote ANC and hospital deliveries in her own community. If women cannot attend ANC, technicians acquired scans by using portable ultrasound machines in her community directly and sent them almost in real time to be analyzed by a gynecologist in an urban hospital. A preliminary survey to assess ANC status preceding the pilot study was conducted. During this, one hundred women who had had pregnancies within five years prior to the study were interviewed. The preliminary survey showed that women who attended ANC were less likely to have a miscarriage and more likely to have delivery at hospital or clinic than those who did not, and women who attained at least four ANC visits were less likely to practice self-medication. Among the women involved in the project, 40 gave birth during the period of observation. The proposed prenatal care approach showed that 62.5 % of pregnant women who gave birth during the observation period included in the project (n=40) had their labor attended in clinics or hospitals as against 37.5 % among the cases reported in the pre-survey. One case of ectopic and two cases of breech pregnancies were detected during the pilot through the proposed approach, and appropriate medical interventions were sought. Our results show that the proposed

  9. Is a positive L-dimer result a sufficient indication for performing a V/Q lung scan?

    International Nuclear Information System (INIS)

    Salanitri, G.C.; Kelly, M.J.; O'Donnell, M.; Kalff, V.

    2002-01-01

    Full text: At our institution there has developed a practice of referring some patients for assessment of pulmonary embolism (PE) because of a positive L-dimer test but without standard clinical indications. Therefore this study aimed to determine whether a positive L-dimer test result by itself is a sufficient indication to perform a ventilation/perfusion V/Q study. V/Q lung scan results, L-dimer test results and appropriate radiology results of 949 consecutive patients from August 2000 to October 2001 were retrospectively reviewed. Prediction of V/Q results by L-dimer results was compared with that of clinical risk factors for PE (Risk factor + or -) These factors were dyspnoea, current deep vein thrombosis (DVT), recent orthopaedic procedure or a past history of PE/DVT, Of the 949 patients in the study population, 254 patients had an L-dimer study, with 206 positive and 48 negative L-dimer results. Helical CT was performed in 8 patients with an equivocal V/Q - 4 showed PE and 4 did not. In the 27 patients with a positive L-dimer result and PE on either V-Q scan or CT, 25 (92.6%) had additional recognised major risk factors for PE. A positive L-dimer test is a poor predictor of a positive V/Q scan compared to conventional clinical indications. Thus, a positive L-dimer test result in isolation does not constitute an appropriate indication to perform a V/Q scan. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  10. Improve performance of scanning probe microscopy by balancing tuning fork prongs

    International Nuclear Information System (INIS)

    Ng, Boon Ping; Zhang Ying; Wei Kok, Shaw; Chai Soh, Yeng

    2009-01-01

    This paper presents an approach for improving the Q-factor of tuning fork probe used in scanning probe microscopes. The improvement is achieved by balancing the fork prongs with extra mass attachment. An analytical model is proposed to characterize the Q-factor of a tuning fork probe with respect to the attachment of extra mass on the tuning fork prongs, and based on the model, the Q-factors of the unbalanced and balanced tuning fork probes are derived and compared. Experimental results showed that the model fits well the experimental data and the approach can improve the Q-factor by more than a factor of three. The effectiveness of the approach is further demonstrated by applying the balanced probe on an atomic force microscope to obtain improved topographic images.

  11. High Performance Protein Sequence Database Scanning on the Cell Broadband Engine

    Directory of Open Access Journals (Sweden)

    Adrianto Wirawan

    2009-01-01

    Full Text Available The enormous growth of biological sequence databases has caused bioinformatics to be rapidly moving towards a data-intensive, computational science. As a result, the computational power needed by bioinformatics applications is growing rapidly as well. The recent emergence of low cost parallel multicore accelerator technologies has made it possible to reduce execution times of many bioinformatics applications. In this paper, we demonstrate how the Cell Broadband Engine can be used as a computational platform to accelerate two approaches for protein sequence database scanning: exhaustive and heuristic. We present efficient parallelization techniques for two representative algorithms: the dynamic programming based Smith–Waterman algorithm and the popular BLASTP heuristic. Their implementation on a Playstation®3 leads to significant runtime savings compared to corresponding sequential implementations.

  12. 3D Flow reconstruction using ultrasound PIV

    Science.gov (United States)

    Poelma, C.; Mari, J. M.; Foin, N.; Tang, M.-X.; Krams, R.; Caro, C. G.; Weinberg, P. D.; Westerweel, J.

    2011-04-01

    Ultrasound particle image velocimetry (PIV) can be used to obtain velocity fields in non-transparent geometries and/or fluids. In the current study, we use this technique to document the flow in a curved tube, using ultrasound contrast bubbles as flow tracer particles. The performance of the technique is first tested in a straight tube, with both steady laminar and pulsatile flows. Both experiments confirm that the technique is capable of reliable measurements. A number of adaptations are introduced that improve the accuracy and applicability of ultrasound PIV. Firstly, due to the method of ultrasound image acquisition, a correction is required for the estimation of velocities from tracer displacements. This correction accounts for the fact that columns in the image are recorded at slightly different instances. The second improvement uses a slice-by-slice scanning approach to obtain three-dimensional velocity data. This approach is here demonstrated in a strongly curved tube. The resulting flow profiles and wall shear stress distribution shows a distinct asymmetry. To meaningfully interpret these three-dimensional results, knowledge of the measurement thickness is required. Our third contribution is a method to determine this quantity, using the correlation peak heights. The latter method can also provide the third (out-of-plane) component if the measurement thickness is known, so that all three velocity components are available using a single probe.

  13. Synthetic aperture tissue and flow ultrasound imaging

    DEFF Research Database (Denmark)

    Nikolov, Svetoslav

    imaging applied to medical ultrasound. It is divided into two major parts: tissue and blood flow imaging. Tissue imaging using synthetic aperture algorithms has been investigated for about two decades, but has not been implemented in medical scanners yet. Among the other reasons, the conventional scanning...... and beamformation methods are adequate for the imaging modalities in clinical use - the B-mode imaging of tissue structures, and the color mapping of blood flow. The acquisition time, however, is too long, and these methods fail to perform real-time three-dimensional scans. The synthetic transmit aperture......, on the other hand, can create a Bmode image with as little as 2 emissions, thus significantly speeding-up the scan procedure. The first part of the dissertation describes the synthetic aperture tissue imaging. It starts with an overview of the efforts previously made by other research groups. A classification...

  14. PERFORMANCE OF QUANTITATIVE ULTRASOUND AND SIX OSTEOPOROSIS RISK INDEXES IN MENOPAUSAL WOMEN: VALIDATION AND COMPARATIVE EVALUATION STUDY.

    Directory of Open Access Journals (Sweden)

    Imad GHOZLANI

    2016-12-01

    Full Text Available Background: A number of questionnaire-based systems and the use of portable quantitative ultrasound scanners (QUS have been devised in an attempt to produce a cost-effective method of screening for osteoporosis.Objective: to assess the sensitivity and specificity of different techniques and their ability to act as screening tools in relation to dual energy X-ray absorptiometry (DXA.Methods: 295 white postmenopausal women aged over 60 were enrolled. Each subject completed a standardized questionnaire which permits the measure of six osteoporosis indexes and had bone mineral density (BMD measured using QUS and DXA. Sensitivity and specificity of the different techniques in relation to DXA were plotted as receiver-operating characteristic (ROC curves at DXA T-score total hip ≤ -2.5 (osteoporosis.Results: BUA sensitivity and specificity values were respectively 76.8% and 51.2% at the total hip. The optimal cut-off T-score for QUS was -2 at the total hip. The osteoporosis self-assessment tool (OST provided consistently the highest AUC (0.80 among the clinical tools and had the best sensitivity and specificity balance (90.2%-44.5%. OST negative likelihood ratio was 0.22.Conclusion: OST (based only on the weight and the age performed slightly better than QUS and other risk questionnaires in predicting low BMD at the total hip

  15. Study on value of Extended-Focused Abdominal Scan For Trauma (e-FAST performed by non-radiologist emergency care doctors in Management of Trauma at Emergency Trauma Centre, Teaching Hospital, Karapitiya,Galle, Sri Lanka

    Directory of Open Access Journals (Sweden)

    Seneviratne RW

    2015-05-01

    Full Text Available Background This study was designed to evaluate the accuracy and usefulness of ultrasound in the hands of emergency physicians and medical officers who are non-radiologistsin assessing Trauma patients at Emergency Trauma Centre(ETC at Teaching Hospital, Karapitiya, Galle, Sri Lanka Methodology We performed an observational study on Trauma patients admitted to Emergency Department at Teaching Hospital, Karapitiya from 1.12.2014 to 31.12.2014 who fulfilled indications for e-FAST using a specially designed performa. Accuracy of eFAST was tested by comparing the original with subsequent imaging, clinical decision by surgeons, findings at surgery or more than one of the above. Results 69 patients fulfilled the entry criteria.Nineteen of the scans were performed by consultants while rest was done by senior medical officers. All of them were trained in eFAST. Of the 20 scans which were positive there were four pneumothoraxes and one haemothorax. 15 scans which were positive for intraperitoneal free fluid were later. Out of 49 Patients who had negative scans 47 did not require surgery or any interventions. Other two required laparotomy later. Sensitivity and specificity ofeFast was 90.4% and 97.9% respectively. Positive predictive value was 95.0% while Negative predictive value was at 95.9% . Conclusions eFAST is a rapidand reliable alternative in detecting free intra-abdominal fluid as well as pneumotorax and haemothorax. It is a safe decision making tool which can be used with confidence and accuracy after brief training and experience by non radiologists which will reduce morbidity and mortality in trauma patients of Sri Lanka.

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  17. Determination of gestational age by ultrasound.

    Science.gov (United States)

    Butt, Kimberly; Lim, Ken

    2014-02-01

    (such as fetal growth restriction or macrosomia) result in a discrepancy between ultrasound biometric and clinical gestational age. Such reassignment may lead to the omission of appropriate-or the performance of inappropriate-fetal interventions. Summary Statements 1. When performed with quality and precision, ultrasound alone is more accurate than a "certain" menstrual date for determining gestational age in the first and second trimesters (≤ 23 weeks) in spontaneous conceptions, and it is the best method for estimating the delivery date. (II) 2. In the absence of better assessment of gestational age, routine ultrasound in the first or second trimester reduces inductions for post-term pregnancies. (I) 3. Ideally, every pregnant woman should be offered a first-trimester dating ultrasound; however, if the availability of obstetrical ultrasound is limited, it is reasonable to use a second-trimester scan to assess gestational age. (I) 4. Notwithstanding Summary Statements 1, 2, and 3, women vary greatly in their awareness of their internal functions, including ovulation, and this self-knowledge can sometimes be very accurate. (III) Recommendations 1. First-trimester crown-rump length is the best parameter for determining gestational age and should be used whenever appropriate. (I-A) 2. If there is more than one first-trimester scan with a mean sac diameter or crown-rump length measurement, the earliest ultrasound with a crown-rump length equivalent to at least 7 weeks (or 10 mm) should be used to determine the gestational age. (III-B) 3. Between the 12th and 14th weeks, crown-rump length and biparietal diameter are similar in accuracy. It is recommended that crown-rump length be used up to 84 mm, and the biparietal diameter be used for measurements > 84 mm. (II-1A) 4. Although transvaginal ultrasound may better visualize early embryonic structures than a transabdominal approach, it is not more accurate in determining gestational age. Crown-rump length measurement from

  18. Ultrasound manifestation of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, M S; Yoo, H S; Park, C Y; Choi, H J; Moon, Y M; Lee, S I [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1982-06-15

    With the advent of gray scale ultrasonographic equipment, the parenchymal disease of liver is more easily evaluated. Ultrasonography is a non-invasive technique, different from angiography, and performed without discomfort to patient. And also ultrasonography can be used in assessing the liver in cases showing equivocal scintigraphy and in differentiation of solid and cystic masses, first detected on scintigrams. Therefore, the complementary use of ultrasonography, Tc-99m-sulfur colloid scan and angiography provides better diagnostic accuracy for the detection of hepatocellular carcinoma, and moreover, sequential ultrasonographic studies in the same patient are valuable of following the course of hepatocellular carcinoma and monitoring the effectiveness of therapy for hepatocellular carcinoma. In thirty patients with histologically proven hepatocellular carcinoma, an analysis of ultrasound manifestation is made and the results are as follows; 1. Ultrasound manifestation of hepatocellular carcinoma by gray scale showed four different sonographic patterns including discrete echo free, discrete echogenic, ill defined echogenic and mixed patterns. 2. The size of hepatocellular carcinoma by ultrasonographic measurement was larger than 5 cm in diameter in 28 cases. 3. In 7 cases performed with angiography, all echogenicities of hepatocellualr carcinoma were correlated with the findings of vascularity of angiography. 4. In cases combined with liver cirrhosis, the sonographic pattern of hepatocellular carcinoma appeared to be discrete or ill defined echogenic patterns.

  19. Ultrasound manifestation of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Hwang, M. S.; Yoo, H. S.; Park, C. Y.; Choi, H. J.; Moon, Y. M.; Lee, S. I.

    1982-01-01

    With the advent of gray scale ultrasonographic equipment, the parenchymal disease of liver is more easily evaluated. Ultrasonography is a non-invasive technique, different from angiography, and performed without discomfort to patient. And also ultrasonography can be used in assessing the liver in cases showing equivocal scintigraphy and in differentiation of solid and cystic masses, first detected on scintigrams. Therefore, the complementary use of ultrasonography, Tc-99m-sulfur colloid scan and angiography provides better diagnostic accuracy for the detection of hepatocellular carcinoma, and moreover, sequential ultrasonographic studies in the same patient are valuable of following the course of hepatocellular carcinoma and monitoring the effectiveness of therapy for hepatocellular carcinoma. In thirty patients with histologically proven hepatocellular carcinoma, an analysis of ultrasound manifestation is made and the results are as follows; 1. Ultrasound manifestation of hepatocellular carcinoma by gray scale showed four different sonographic patterns including discrete echo free, discrete echogenic, ill defined echogenic and mixed patterns. 2. The size of hepatocellular carcinoma by ultrasonographic measurement was larger than 5 cm in diameter in 28 cases. 3. In 7 cases performed with angiography, all echogenicities of hepatocellualr carcinoma were correlated with the findings of vascularity of angiography. 4. In cases combined with liver cirrhosis, the sonographic pattern of hepatocellular carcinoma appeared to be discrete or ill defined echogenic patterns

  20. Diagnostic Performance and Confidence of Contrast-Enhanced Ultrasound in the Differential Diagnosis of Cystic and Cysticlike Liver Lesions.

    Science.gov (United States)

    Corvino, Antonio; Catalano, Orlando; Corvino, Fabio; Sandomenico, Fabio; Petrillo, Antonella

    2017-09-01

    The aims of this study were to assess the diagnostic performance of contrast-enhanced ultrasound (CEUS) in the characterization of atypical cystic and cysticlike focal liver lesions in comparison with conventional US and to determine whether the use of CEUS can reduce the need for further diagnostic workup. In a 3-year period 48 patients with 50 atypical cystic and cysticlike lesions found at conventional US underwent CEUS. Diagnostic confirmation was obtained in cytohistopathologic examinations, with other imaging modalities, and in follow-up. Overall, there were 24 cystic lesions and 26 cysticlike solid lesions, specifically 32 benign and 18 malignant lesions. The conventional US and CEUS images and cine loops were reviewed by two blinded readers independently. Sensitivity, specificity, area under the ROC curve (A z ), and interobserver agreement were calculated. Diagnostic performance improved after review of CEUS examinations by both readers (conventional US A z = 0.781 vs 0.972; CEUS A z = 0.734 vs 0.957). Interreader agreement increased, although slightly (conventional US weighted κ = 0.894; CEUS weighted κ = 0.953). In terms of differential diagnosis, the occurrence of correctly characterized lesions increased after CEUS for both readers (reader 1, 62% to 98%; reader 2, 56% to 96%). The development of low-acoustic-power CEUS has made it possible to identify several imaging features of cystic and cysticlike focal liver lesions that, in association with history and clinical findings, may help to correctly characterize them. Our data indicate the usefulness of CEUS in the evaluation of patients with these lesions.

  1. Assessing the performance of commercial Agisoft PhotoScan software to deliver reliable data for accurate3D modelling

    Directory of Open Access Journals (Sweden)

    Jebur Ahmed

    2018-01-01

    Full Text Available 3D models delivered from digital photogrammetric techniques have massively increased and developed to meet the requirements of many applications. The reliability of these models is basically dependent on the data processing cycle and the adopted tool solution in addition to data quality. Agisoft PhotoScan is a professional image-based 3D modelling software, which seeks to create orderly, precise n 3D content from fixed images. It works with arbitrary images those qualified in both controlled and uncontrolled conditions. Following the recommendations of many users all around the globe, Agisoft PhotoScan, has become an important source to generate precise 3D data for different applications. How reliable is this data for accurate 3D modelling applications is the current question that needs an answer. Therefore; in this paper, the performance of the Agisoft PhotoScan software was assessed and analyzed to show the potential of the software for accurate 3D modelling applications. To investigate this, a study was carried out in the University of Baghdad / Al-Jaderia campus using data collected from airborne metric camera with 457m flying height. The Agisoft results show potential according to the research objective and the dataset quality following statistical and validation shape analysis.

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... inserted into a man's rectum to view the prostate. Transvaginal ultrasound. The transducer is inserted into a ... Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos ...

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce ... the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, and ...

  4. Performance of confocal scanning laser tomograph Topographic Change Analysis (TCA) for assessing glaucomatous progression.

    Science.gov (United States)

    Bowd, Christopher; Balasubramanian, Madhusudhanan; Weinreb, Robert N; Vizzeri, Gianmarco; Alencar, Luciana M; O'Leary, Neil; Sample, Pamela A; Zangwill, Linda M

    2009-02-01

    To determine the sensitivity and specificity of confocal scanning laser ophthalmoscope's Topographic Change Analysis (TCA; Heidelberg Retina Tomograph [HRT]; Heidelberg Engineering, Heidelberg, Germany) parameters for discriminating between progressing glaucomatous and stable healthy eyes. The 0.90, 0.95, and 0.99 specificity cutoffs for various (n=70) TCA parameters were developed by using 1000 permuted topographic series derived from HRT images of 18 healthy eyes from Moorfields Eye Hospital, imaged at least four times. The cutoffs were then applied to topographic series from 36 eyes with known glaucomatous progression (by optic disc stereophotograph assessment and/or standard automated perimetry guided progression analysis, [GPA]) and 21 healthy eyes from the University of California, San Diego (UCSD) Diagnostic Innovations in Glaucoma Study (DIGS), all imaged at least four times, to determine TCA sensitivity and specificity. Cutoffs also were applied to 210 DIGS patients' eyes imaged at least four times with no evidence of progression (nonprogressed) by stereophotography or GPA. The TCA parameter providing the best sensitivity/specificity tradeoff using the 0.90, 0.95, and 0.99 cutoffs was the largest clustered superpixel area within the optic disc margin (CAREA(disc) mm(2)). Sensitivities/specificities for classifying progressing (by stereophotography and/or GPA) and healthy eyes were 0.778/0.809, 0.639/0.857, and 0.611/1.00, respectively. In nonprogressing eyes, specificities were 0.464, 0.570, and 0.647 (i.e., lower than in the healthy eyes). In addition, TCA parameter measurements of nonprogressing eyes were similar to those of progressing eyes. TCA parameters can discriminate between progressing and longitudinally observed healthy eyes. Low specificity in apparently nonprogressing patients' eyes suggests early progression detection using TCA.

  5. Bedside Ultrasound for the Diagnosis of Small Bowel Obstruction

    Directory of Open Access Journals (Sweden)

    Alexander Anshus

    2017-09-01

    Full Text Available History of present illness: An elderly female with no history of prior abdominal surgeries presented to the emergency department (ED with acute onset of abdominal pain and distention. Upon arrival, she began having large volume bilious emesis. While waiting for a computed tomography (CT scan of her abdomen and pelvis, a point of care ultrasound (POCUS was performed which showed evidence of a small bowel obstruction (SBO. The patient had a nasogastric tube placed that put out over two liters of bilious contents. A subsequent CT scan confirmed the diagnosis of SBO from a left inguinal hernia and the patient was admitted to the surgical service. Significant findings: The POCUS utilizing the low frequency curvilinear probe demonstrates fluid-filled, dilated bowel loops greater than 2.5cm with to-and-fro peristalsis, and thickened bowel walls greater than 3mm, concerning for SBO. Discussion: Gastrointestinal obstruction is a common diagnosis in the ED, accounting for approximately 15% of all ED visits for acute abdominal pain.1 SBO accounts for approximately 80% of all obstructions.2 In the diagnosis of SBO, studies show that abdominal x-rays have a sensitivity of 66-77% and specificity of 50-57%,3 CT scans have a sensitivity of 92% and specificity of 93%,4 and ultrasound has a sensitivity of 88% and specificity of 96%.5 While CT scan remains a widely accepted modality for diagnosing SBO, ultrasound is more cost effective, well tolerated, does not involve ionizing radiation, and can be done in a timely manner at the patient’s bedside. Ultrasound can also identify transition points as well as distinguish between functional and mechanical obstruction.6 In addition to SBO, ultrasound can be used to diagnose external hernias, intussusception, tumors, superior mesenteric artery (SMA syndrome, foreign bodies, bezoars, and ascariasis.7

  6. Compact Beamformer Design with High Frame Rate for Ultrasound Imaging

    Directory of Open Access Journals (Sweden)

    Jun Luo

    2014-04-01

    Full Text Available In medical field, two-dimension ultrasound images are widely used in clinical diagnosis. Beamformer is critical in determining the complexity and performance of an ultrasound imaging system. Different from traditional means implemented with separated chips, a compact beamformer with 64 effective channels in a single moderate Field Programmable Gate Array has been presented in this paper. The compactness is acquired by employing receive synthetic aperture, harmonic imaging, time sharing and linear interpolation. Besides that, multi-beams method is used to improve the frame rate of the ultrasound imaging system. Online dynamic configuration is employed to expand system’s flexibility to two kinds of transducers with multi-scanning modes. The design is verified on a prototype scanner board. Simulation results have shown that on-chip memories can be saved and the frame rate can be improved on the case of 64 effective channels which will meet the requirement of real-time application.

  7. Diagnostic performance of multi-organ ultrasound with pocket-sized device in the management of acute dyspnea.

    Science.gov (United States)

    Sforza, Alfonso; Mancusi, Costantino; Carlino, Maria Viviana; Buonauro, Agostino; Barozzi, Marco; Romano, Giuseppe; Serra, Sossio; de Simone, Giovanni

    2017-06-19

    The availability of ultra-miniaturized pocket ultrasound devices (PUD) adds diagnostic power to the clinical examination. Information on accuracy of ultrasound with handheld units in immediate differential diagnosis in emergency department (ED) is poor. The aim of this study is to test the usefulness and accuracy of lung ultrasound (LUS) alone or combined with ultrasound of the heart and inferior vena cava (IVC) using a PUD for the differential diagnosis of acute dyspnea (AD). We included 68 patients presenting to the ED of "Maurizio Bufalini" Hospital in Cesena (Italy) for AD. All patients underwent integrated ultrasound examination (IUE) of lung-heart-IVC, using PUD. The series was divided into patients with dyspnea of cardiac or non-cardiac origin. We used 2 × 2 contingency tables to analyze sensitivity, specificity, positive predictive value and negative predictive value of the three ultrasonic methods and their various combinations for the diagnosis of cardiogenic dyspnea (CD), comparing with the final diagnosis made by an independent emergency physician. LUS alone exhibited a good sensitivity (92.6%) and specificity (80.5%). The highest accuracy (90%) for the diagnosis of CD was obtained with the combination of LUS and one of the other two methods (heart or IVC). The IUE with PUD is a useful extension of the clinical examination, can be readily available at the bedside or in ambulance, requires few minutes and has a reliable diagnostic discriminant ability in the setting of AD.

  8. Feasibility of Remote Real-Time Guidance of a Cardiac Examination Performed by Novices Using a Pocket-Sized Ultrasound Device

    Directory of Open Access Journals (Sweden)

    Tuan V. Mai

    2013-01-01

    Full Text Available Background. The potential of pocket-sized ultrasound devices (PUDs to improve global healthcare delivery is limited by the lack of a suitable imaging protocol and trained users. Therefore, we investigated the feasibility of performing a brief, evidence-based cardiac limited ultrasound exam (CLUE through wireless guidance of novice users. Methods. Three trainees applied PUDs on 27 subjects while directed by an off-site cardiologist to obtain a CLUE to screen for LV systolic dysfunction (LVSD, LA enlargement (LAE, ultrasound lung comets (ULC+, and elevated CVP (eCVP. Real-time remote audiovisual guidance and interpretation by the cardiologist were performed using the iPhone 4/iPod (FaceTime, Apple, Inc. attached to the PUD and transmitted data wirelessly. Accuracy and technical quality of transmitted images were compared to on-site, gold-standard echo thresholds. Results. Novice versus sonographer imaging yielded technically adequate views in 122/135 (90% versus 130/135 (96% (. CLUE’s combined SN, SP, and ACC were 0.67, 0.96, and 0.90. Technical adequacy (% and accuracy for each abnormality ( were LVSD (85%, 0.93, , LAE (89%, 0.74, , ULC+ (100%, 0.94, , and eCVP (78%, 0.91, . Conclusion. A novice can perform the CLUE using PUD when wirelessly guided by an expert. This method could facilitate PUD use for off-site bedside medical decision making and triaging of patients.

  9. Bilateral periventricular nodular heterotopia – neonatal cranial ultrasound.

    Directory of Open Access Journals (Sweden)

    A R Horn

    2010-03-01

    Full Text Available A female neonate was delivered at 30 weeks’ gestation to a mother with suspected bilateral periventricular nodular heterotopia (PNH on computed tomography brain scan. Antenatal ultrasound (US performed at 28 weeks’ gestation showed mild lateral cerebral ventricle dilatation, but no other fetal anomalies. Clinical examination revealed mild dysmorphic features: facial and skull asymmetry, square-shaped ears, and long tapering fingers. Chromosomal analysis showed a 46XX karyotype.

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... be able to give a clearer picture of soft tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding ...

  11. Prostate Ultrasound

    Science.gov (United States)

    ... be able to give a clearer picture of soft tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to ...

  13. Interventional ultrasound

    International Nuclear Information System (INIS)

    VanSonnenberg, E.

    1987-01-01

    This book contains 12 chapters and several case studies. Some of the chapter titles are: The Interplay of Ultrasound and Computed Tomography in the Planning and Execution of Interventional Procedures: Ulltrasound Guided Biopsy; Interventioal Genitourinary Sonography; Diagnosis and Treatment of Pericardial Effusion Using Ultrasonic Guidance; and New Ultrasound-Guided Interventional Procedures--Cholecystostomy, Pancreatography, Gastrostomy

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of ...

  16. Ultrasound stethoscopy

    NARCIS (Netherlands)

    E.C. Vourvouri (Eleni)

    2002-01-01

    textabstractIn this thesis we repmi the many evaluation studies with the hand-held ultrasound device in the assessment of different cardiac pathologies and in different clinical settings. The reason for using the tetm "ultrasound stethoscopy" is that these devices are augmenting our

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the best way to see if treatment is working or if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  19. Phenotypic and genetic relationships of feed efficiency with growth performance, ultrasound, and carcass merit traits in Angus and Charolais steers.

    Science.gov (United States)

    Mao, F; Chen, L; Vinsky, M; Okine, E; Wang, Z; Basarab, J; Crews, D H; Li, C

    2013-05-01

    Feed efficiency is of particular importance to the beef industry, as feed costs represent the single largest variable cost in beef production systems. Selection for more efficient cattle will lead to reduction of feed related costs, but should not have adverse impacts on quality of the carcass. In this study, we evaluated phenotypic and genetic correlations of residual feed intake (RFI), RFI adjusted for end-of-test ultrasound backfat thickness (RFIf), and RFI adjusted for ultrasound backfat thickness and LM area (RFIfr) with growth, ultrasound, and carcass merit traits in an Angus population of 551 steers and in a Charolais population of 417 steers. In the Angus steer population, the phenotypic and genetic correlation of RFI with carcass merit traits including HCW, carcass backfat, carcass LM area, lean meat yield, and carcass marbling were not significant or weak with correlations coefficients ranging from -0.0007 ± 0.05 to 0.18 ± 0.21. In the Charolais steer population, the phenotypic and genetic correlations of RFI with the carcass merit traits were also weak, with correlation coefficients ranging from -0.07 ± 0.06 to 0.19 ± 0.18, except for the genetic correlation with carcass average backfat, which was moderate with a magnitude of 0.42 ± 0.29. Inclusion of ultrasound backfat thickness in the model to predict the expected daily DMI for maintenance explained on average an additional 0.5% variation of DMI in the Angus steers and 2.3% variation of DMI in the Charolais steer population. Inclusion of both the ultrasound backfat and LM area in the model explained only 0.7% additional variance in DMI in the Angus steer population and only 0.6% in the Charolais steer population on top of the RFIf model. We concluded that RFIf adjusted for ultrasound backfat at the end of the test will lead to decreases of both the phenotypic and genetic correlations with carcass backfat and marbling score to a greater extent for late-maturing beef breeds such as Charolais than

  20. Ultrasound guidance to perform intra-articular injection of gadolinium-based contrast material for magnetic resonance arthrography as an alternative to fluoroscopy: the time is now

    Energy Technology Data Exchange (ETDEWEB)

    Messina, Carmelo [Universita degli Studi di Milano, Scuola di Specializzazione in Radiodiagnostica, Milano (Italy); Banfi, Giuseppe [IRCCS Istituto Ortopedico Galeazzi, Milano (Italy); Universita Vita-Salute San Raffaele, Milano (Italy); Aliprandi, Alberto [Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, Milano (Italy); Mauri, Giovanni [Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, Milano (Italy); Istituto Europeo di Oncologia, Unita di Radiologia Interventistica, Milano (Italy); Secchi, Francesco; Sardanelli, Francesco; Sconfienza, Luca Maria [Universita degli Studi di Milano, Dipartimento di Scienze Biomediche per la Salute, Milano (Italy); IRCCS Policlinico San Donato, Servizio di Radiologia, San Donato, Milanese (Italy)

    2016-05-15

    Magnetic resonance (MR) imaging has been definitively established as the reference standard in the evaluation of joints in the body. Similarly, magnetic resonance arthrography has emerged as a technique that has been proven to increase significantly the diagnostic performance if compared with conventional MR imaging, especially when dealing with fibrocartilage and articular cartilage abnormalities. Diluted gadolinium can be injected in the joint space using different approaches: under palpation using anatomic landmarks or using an imaging guidance, such as fluoroscopy, computed tomography, or ultrasound. Fluoroscopy has been traditionally used, but the involvement of ionizing radiation should represent a remarkable limitation of this modality. Conversely, ultrasound has emerged as a feasible, cheap, quick, and radiation-free modality that can be used to inject joints, with comparable accuracy of fluoroscopy. In the present paper, we discuss the advantages and disadvantages of using fluoroscopy or ultrasound in injecting gadolinium-based contrast agents in joints to perform magnetic resonance arthrography, also in view of the new EuroSAFE Imaging initiative promoted by the European Society of Radiology and the recent updates to the European Atomic Energy Community 2013/59 directive on the medical use of ionizing radiation. (orig.)

  1. Is it time to include point-of-care ultrasound in general surgery training? A review to stimulate discussion.

    Science.gov (United States)

    Mollenkopf, Maximilian; Tait, Noel

    2013-12-01

    Point-of-care ultrasound scanning or POCUS is a focused ultrasound (US) scan, performed by non-imaging clinicians during physical examination, an invasive procedure or surgery. As this technology becomes cheaper, smaller and easier to use, its scope for use by surgeons grows, a trend that may generate a gap between use and training. Opportunities for enhanced general surgery skill sets may be reduced unless consideration is given to inclusion of POCUS in general surgery training. To stimulate discussion regarding inclusion of POCUS in the general surgery curriculum; to resource this discussion with an overview of current trends and issues around POCUS; and to discuss concerns and controversies that may arise if POCUS was adopted into general surgery training. A literature search was performed using PUBMED, MEDLINE, Google and Google Scholar, using the terms 'ultrasound', 'point-of-care-ultrasound', 'bedside ultrasound', 'portable ultrasound' and 'hand-held ultrasound'. Literature, references and non-literature resources found were reviewed for relevance to US education in general surgery. Increasingly, medical students are graduating with basic POCUS skills. Specialty-specific uses of POCUS are proliferating. Training and assessment resources are not keeping up, in accessibility or standardization. A learned surgical college led training and accreditation process would require aligned education in anatomy and US technology and collaboration with the specialist imaging community to ensure appropriate standards are clarified and met. Research is also required into how general surgery trainees can best achieve and maintain POCUS competence. © 2013 Royal Australasian College of Surgeons.

  2. Quick Green Scan: A Methodology for Improving Green Performance in Terms of Manufacturing Processes

    Directory of Open Access Journals (Sweden)

    Aldona Kluczek

    2017-01-01

    Full Text Available The heating sector has begun implementing technologies and practices to tackle the environmental and social–economic problems caused by their production process. The purpose of this paper is to develop a methodology, “the Quick-Green-Scan”, that caters for the need of quick assessment decision-makers to improve green manufacturing performance in companies that produce heating devices. The study uses a structured approach that integrates Life Cycle Assessment-based indicators, framework and linguistic scales (fuzzy numbers to evaluate the extent of greening of the enterprise. The evaluation criteria and indicators are closely related to the current state of technology, which can be improved. The proposed methodology has been created to answer the question whether a company acts on the opportunity to be green and whether these actions are contributing towards greening, maintaining the status quo or moving away from a green outcome. Results show that applying the proposed improvements in processes helps move the facility towards being a green enterprise. Moreover, the methodology, being particularly quick and simple, is a practical tool for benchmarking, not only in the heating industry, but also proves useful in providing comparisons for facility performance in other manufacturing sectors.

  3. Prevalence and diagnostic performance of computed tomography angiography spot sign for intracerebral hematoma expansion depend on scan timing

    Energy Technology Data Exchange (ETDEWEB)

    Tsukabe, Akio; Watanabe, Yoshiyuki; Tanaka, Hisashi; Kunitomi, Yuki; Nishizawa, Mitsuo; Arisawa, Atsuko; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan); Yoshiya, Kazuhisa; Shimazu, Takeshi [Osaka University Graduate School of Medicine, Department of Traumatology and Acute Critical Medicine, Suita, Osaka (Japan)

    2014-12-15

    The computed tomography angiography (CTA) spot sign correlates with intracerebral hemorrhage (ICH) expansion; however, various diagnostic performances for hematoma expansion, especially in sensitivity, have been reported. We aimed to assess the impact of scan timing of CTA on the diagnostic performance of the CTA spot sign for ICH expansion in two different arterial phases within patients. Eighty-three consecutive patients with primary ICH who received two sequential CTAs were recruited. Two neuroradiologists reviewed CTAs for CTA spot signs, while one reviewed initial and follow-up non-contrast CT for measuring ICH volume. The time interval between two phases was then calculated, and the diagnostic performance of CTA spot sign in each phase was evaluated. CTA spot signs were observed in 20/83 (24.1 %) patients in the early phase and 44/83 (53.0 %) patients in the late phase. The mean time interval between the two phases was 12.7 s. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for hematoma progression of CTA spot sign were 48.1, 87.5, 65.0, 77.8, and 74.7 %, respectively, in early phase and 92.6, 66.1, 56.8, 94.9, and 74.7 %, respectively, in late phase. The CTA spot sign was significantly associated with ICH expansion in early (P < 0.001) and late (P < 0.00001) phases (Pearson's chi-square test). A mere 10-s difference in scan timing could make a difference on prevalence and diagnostic performance of the CTA spot sign, suggesting a need for the standardization of the CTA protocol to generalize the approach for effective clinical application. (orig.)

  4. Physics of Ultrasound. Chapter 12

    Energy Technology Data Exchange (ETDEWEB)

    Lacefield, J. C. [University of Western Ontario, London (Canada)

    2014-09-15

    Ultrasound is the most commonly used diagnostic imaging modality, accounting for approximately 25% of all imaging examinations performed worldwide at the beginning of the 21st century. The success of ultrasound may be attributed to a number of attractive characteristics, including the relatively low cost and portability of an ultrasound scanner, the non-ionizing nature of ultrasound waves, the ability to produce real time images of blood flow and moving structures such as the beating heart, and the intrinsic contrast among soft tissue structures that is achieved without the need for an injected contrast agent. The latter characteristic enables ultrasound to be used for a wide range of medical applications, which historically have primarily included cardiac and vascular imaging, imaging of the abdominal organs and, most famously, in utero imaging of the developing fetus. Ongoing technological improvements continue to expand the use of ultrasound for many applications, including cancer imaging, musculoskeletal imaging, ophthalmology and others. The term ultrasound refers specifically to acoustic waves at frequencies greater than the maximum frequency audible to humans, which is nominally 20 kHz. Diagnostic imaging is generally performed using ultrasound in the frequency range of 2–15 MHz. The choice of frequency is dictated by a trade off between spatial resolution and penetration depth, since higher frequency waves can be focused more tightly but are attenuated more rapidly by tissue. The information contained in an ultrasonic image is influenced by the physical processes underlying propagation, reflection and attenuation of ultrasound waves in tissue.

  5. 'Peripheric' pancreatic cysts: performance of CT scan, MRI and endoscopy according to final pathological examination.

    Science.gov (United States)

    Duconseil, P; Turrini, O; Ewald, J; Soussan, J; Sarran, A; Gasmi, M; Moutardier, V; Delpero, J R

    2015-06-01

    To assess the accuracy of pre-operative staging in patients with peripheral pancreatic cystic neoplasms (pPCNs). From 2005 to 2011, 148 patients underwent a pancreatectomy for pPCNs. The pre-operative examination methods of computed tomography (CT), magnetic resonance imaging (MRI), endoscopic ultrasonography (EUS) were compared for their ability to predict the suggested diagnosis accurately, and the definitive diagnosis was affirmed by pathological examination. A mural nodule was detected in 34 patients (23%): only 1 patient (3%) had an invasive pPCN at the final histological examination. A biopsy was performed in 79 patients (53%) during EUS: in 55 patients (70%), the biopsy could not conclude a diagnosis; the biopsy provided the correct and wrong diagnosis in 19 patients (24%) and 5 patients (6%), respectively. A correct diagnosis was affirmed by CT, EUS and pancreatic MRI in 60 (41%), 103 (74%) and 80 (86%) patients (when comparing EUS and MRI; P = 0.03), respectively. The positive predictive values (PPVs) of CT, EUS and MRI were 70%, 75% and 87%, respectively. Pancreatic MRI appears to be the most appropriate examination to diagnose pPCNs accurately. EUS alone had a poor PPV. Mural nodules in a PCN should not be considered an indisputable sign of pPCN invasiveness. © 2015 International Hepato-Pancreato-Biliary Association.

  6. High definition ultrasound imaging for battlefield medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Kwok, K.S.; Morimoto, A.K.; Kozlowski, D.M.; Krumm, J.C.; Dickey, F.M. [Sandia National Labs., Albuquerque, NM (United States); Rogers, B; Walsh, N. [Texas Univ. Health Science Center, San Antonio, TX (United States)

    1996-06-23

    A team has developed an improved resolution ultrasound system for low cost diagnostics. This paper describes the development of an ultrasound based imaging system capable of generating 3D images showing surface and subsurface tissue and bone structures. We include results of a comparative study between images obtained from X-Ray Computed Tomography (CT) and ultrasound. We found that the quality of ultrasound images compares favorably with those from CT. Volumetric and surface data extracted from these images were within 7% of the range between ultrasound and CT scans. We also include images of porcine abdominal scans from two different sets of animal trials.

  7. The effect of dyad versus individual simulation-based ultrasound training on skills transfer

    DEFF Research Database (Denmark)

    Tolsgaard, Martin G; Madsen, Mette E; Oxlund, Birgitte S

    2015-01-01

    : This study was conducted to compare the effectiveness of simulation-based ultrasound training in pairs (dyad practice) with that of training alone (single-student practice) on skills transfer. METHODS: In a non-inferiority trial, 30 ultrasound novices were randomised to dyad (n = 16) or single-student (n...... through pre-, post- and transfer tests. The transfer test involved the assessment of a transvaginal ultrasound scan by one of two clinicians using the Objective Structured Assessment of Ultrasound Skills (OSAUS). RESULTS: Thirty participants completed the simulation-based training and 24...... interactions between training type and performance (p = 0.59). The dyad group demonstrated higher training efficiency in terms of simulator score per number of attempts compared with the single-student group (p = 0.03). CONCLUSION: Dyad practice improves the efficiency of simulation-based training and is non...

  8. Comparing Performance of Combinations of Shear Wave Elastography and B-Mode Ultrasound in Diagnosing Breast Masses: Is It Influenced by Mass Size?

    Science.gov (United States)

    Cong, Rui; Li, Jing; Wang, Xuejiao

    2017-10-01

    We determined the diagnostic performance of combinations of shear wave elastography (SWE) and B-mode ultrasound (US) in differentiating malignant from benign breast masses, and we investigated whether performance is affected by mass size. In this prospective study of 315 consecutive patients with 326 breast masses, US and SWE were performed before biopsy. Masses were categorized into two subgroups on the basis of mass size (≤15 mm and >15 mm), and the optimal thresholds for the SWE parameters were determined for each subgroup using receiver operating characteristic curves. The combination proposed here achieved an area under the receiver operating characteristic curve of 0.943, 95.00% sensitivity and 81.18% specificity, which approximated the diagnostic performance of US alone. The performance of the combinations using the subgroups' thresholds did not differ significantly from those based on the entire study group's thresholds, but the optimal thresholds were higher in the subgroup of larger masses. Further research is needed to determine whether mass size affects the performance of combinations of SWE and US. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  9. Strain measurement of abdominal aortic aneurysm with real-time 3D ultrasound speckle tracking.

    Science.gov (United States)

    Bihari, P; Shelke, A; Nwe, T H; Mularczyk, M; Nelson, K; Schmandra, T; Knez, P; Schmitz-Rixen, T

    2013-04-01

    Abdominal aortic aneurysm rupture is caused by mechanical vascular tissue failure. Although mechanical properties within the aneurysm vary, currently available ultrasound methods assess only one cross-sectional segment of the aorta. This study aims to establish real-time 3-dimensional (3D) speckle tracking ultrasound to explore local displacement and strain parameters of the whole abdominal aortic aneurysm. Validation was performed on a silicone aneurysm model, perfused in a pulsatile artificial circulatory system. Wall motion of the silicone model was measured simultaneously with a commercial real-time 3D speckle tracking ultrasound system and either with laser-scan micrometry or with video photogrammetry. After validation, 3D ultrasound data were collected from abdominal aortic aneurysms of five patients and displacement and strain parameters were analysed. Displacement parameters measured in vitro by 3D ultrasound and laser scan micrometer or video analysis were significantly correlated at pulse pressures between 40 and 80 mmHg. Strong local differences in displacement and strain were identified within the aortic aneurysms of patients. Local wall strain of the whole abdominal aortic aneurysm can be analysed in vivo with real-time 3D ultrasound speckle tracking imaging, offering the prospect of individual non-invasive rupture risk analysis of abdominal aortic aneurysms. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Enhancement of bone shadow region using local phase-based ultrasound transmission maps.

    Science.gov (United States)

    Hacihaliloglu, Ilker

    2017-06-01

    Ultrasound is increasingly being employed in different orthopedic procedures as an imaging modality for real-time guidance. Nevertheless, low signal-to-noise-ratio and different imaging artifacts continue to hamper the success of ultrasound-based procedures. Bone shadow region is an important feature indicating the presence of bone/tissue interface in the acquired ultrasound data. Enhancement and automatic detection of this region could improve the sensitivity of ultrasound for imaging bone and result in improved guidance for various orthopedic procedures. In this work, a method is introduced for the enhancement of bone shadow regions from B-mode ultrasound data. The method is based on the combination of three different image phase features: local phase tensor, local weighted mean phase angle, and local phase energy. The combined local phase image features are used as an input to an [Formula: see text] norm-based contextual regularization method which emphasizes uncertainty in the shadow regions. The enhanced bone shadow images are automatically segmented and compared against expert segmentation. Qualitative and quantitative validation was performed on 100 in vivo US scans obtained from five subjects by scanning femur and vertebrae bones. Validation against expert segmentation achieved a mean dice similarity coefficient of 0.88. The encouraging results obtained in this initial study suggest that the proposed method is promising enough for further evaluation. The calculated bone shadow maps could be incorporated into different ultrasound bone segmentation and registration approaches as an additional feature.

  11. Ultrasound diagnosis of lower limb deep venous thrombosis.

    Science.gov (United States)

    Fletcher, J P; Kershaw, L Z; Barker, D S; Koutts, J; Varnava, A

    1990-10-15

    Venous ultrasound imaging was compared with ascending contrast venography for the diagnosis of suspected deep vein thrombosis (DVT) in the femoral, popliteal and calf vein segments of 44 limbs in 44 patients. One femoral and one calf vein segment could not be imaged (1.5% of the segments examined), but during the same period venography failed in six patients because of an inability to cannulate a swollen limb. Ultrasound imaging compared with venography as a means of diagnosing DVT showed an overall sensitivity of 95% and a specificity of 92%. The sensitivity and specificity of ultrasound imaging for the diagnosis of both femoral and popliteal vein thromboses were 100% and 97%, respectively, and for calf vein thrombosis were 85% and 83%, respectively. This study supports the recommendation that ultrasound imaging is now the investigation of choice for the diagnosis of DVT provided that the scan is performed by an experienced vascular technologist. Ultrasound imaging may also define other pathological conditions presenting in the differential diagnosis of DVT, such as superficial thrombophlebitis and Baker's cyst.

  12. Fetal Ultrasound

    Science.gov (United States)

    ... isn't recommended simply to determine a baby's sex. Similarly, fetal ultrasound isn't recommended solely for the purpose of producing keepsake videos or pictures. If your health care provider doesn' ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... nodule felt by a physician during a routine physical exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ... well on x-ray images. Ultrasound causes no health problems and may be repeated as often as ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exams are also used to monitor the health and development of an embryo or fetus during ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... the transducer (the device placed on the patient's skin to send and receive the returning sound waves), ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... the transducer (the device placed on the patient's skin to send and receive the returning sound waves), ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... use different transducers (with different capabilities) during a single exam. The transducer sends out high-frequency sound ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the rectal wall is relatively insensitive to the pain in the region of the prostate. A biopsy ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... diagnose symptoms such as difficulty urinating or an elevated blood test result. It’s also used to investigate ... physical exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... The principles are similar to sonar used by boats and submarines. The ultrasound image is immediately visible ... principles involved in the sonar used by bats, ships and fishermen. When a sound wave strikes an ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... areas of the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. For ... make secure contact with the body and eliminate air pockets between the transducer and the skin that ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... a follow-up exam is done because a potential abnormality needs further evaluation with additional views or ... of soft tissues that do not show up well on x-ray images. Ultrasound causes no health ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a follow-up exam is done because a potential abnormality needs further evaluation with additional views or ... of soft tissues that do not show up well on x-ray images. Ultrasound is the preferred ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... less than 20 minutes. top of page What will I experience during and after the procedure? Ultrasound ... in the region of the prostate. A biopsy will add time to the procedure. Rarely, a small ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound images are reviewed. top of page What will I experience during and after the procedure? For ... in the region of the prostate. A biopsy will add time to the procedure. If a Doppler ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... arteries and veins in the abdomen, arms, legs, neck and/or brain (in infants and children) or ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the best way to see if treatment is working or if a finding is stable or changed ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and development of an embryo or fetus during pregnancy. See the Obstetrical Ultrasound page for more information . ... move through vessels. The movement of blood cells causes a change in pitch of the reflected sound ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... abdomen, arms, legs, neck and/or brain (in infants and children) or within various body organs such ... and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time imaging, making it a ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... move through vessels. The movement of blood cells causes a change in pitch of the reflected sound ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  19. Ultrasound imaging

    International Nuclear Information System (INIS)

    Wells, P.N.T.

    1983-01-01

    Ultrasound is a form of energy which consists of mechanical vibrations the frequencies of which are so high that they are above the range of human hearing. The lower frequency limit of the ultrasonic spectrum may generally be taken to be about 20 kHz. Most biomedical applications of ultrasound employ frequencies in the range 1-15 MHz. At these frequencies, the wavelength is in the range 1.5 - 0.1 mm in soft tissues, and narrow beams of ultrasound can be generated which propagate through such tissues without excessive attenuation. This chapter begins with brief reviews of the physics of diagnostic ultrasound pulse-echo imaging methods and Doppler imaging methods. The remainder of the chapter is a resume of the applications of ultrasonic imaging to physiological measurement

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... frequently used to evaluate the reproductive and urinary systems. Ultrasound is safe, noninvasive and does not use ... and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... be asked to drink water prior to the examination to fill your bladder. Leave jewelry at home ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Prostate Cancer top of page ... to Ultrasound - Prostate Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... with measurements acquired as needed for any treatment planning. detect an abnormal growth within the prostate. help ... end of their bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... prostate gland and to help diagnose symptoms such as difficulty urinating or an elevated blood test result. ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is enlarged, also known as benign prostatic hyperplasia (BPH) , with measurements acquired as needed for any treatment ... caption Related Articles and Media Benign Prostatic Hyperplasia (BPH) (Enlargement of the Prostate) Prostate Cancer Ultrasound- and ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the exam. Bringing books, small toys, music or games can help to distract the child and make ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries in planes that ... a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the examination process. To ensure a smooth experience, it often helps to explain the procedure to the ... on the amplitude (loudness), frequency (pitch) and time it takes for the ultrasound signal to return from ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... difficulty urinating or an elevated blood test result. It’s also used to investigate a nodule found during ... difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide procedures such ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ... and Resources RTAnswers.org Radiation Therapy for Prostate Cancer top of page This page was reviewed on ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects on ... and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... rectum. top of page What are some common uses of the procedure? A transrectal ultrasound of the ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... legs, neck and/or brain (in infants and children) or within various body organs such as the ... tumors other disorders of the urinary bladder In children, pelvic ultrasound can help evaluate: pelvic masses pelvic ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterus). Sonohysterography allows for a more in-depth investigation of the uterine cavity . Three-dimensional (3-D) ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... quickly. The ultrasound exam room may have a television. Feel free to ask for your child's favorite ... display screen that looks like a computer or television monitor. The image is created based on the ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Images related to Ultrasound - Prostate Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Images related to Ultrasound - Pelvis Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... also known as benign prostatic hyperplasia (BPH) , with measurements acquired as needed for any treatment planning. detect ... areas of the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. For ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... rectum. top of page What are some common uses of the procedure? A transrectal ultrasound of the ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... kidneys. top of page What are some common uses of the procedure? In women, a pelvic ultrasound ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... various body organs such as the liver or kidneys. top of page What are some common uses ... women, a pelvic ultrasound exam can help identify: kidney stones bladder tumors other disorders of the urinary ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls of the uterus). Sonohysterography allows for a ... and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls of the uterus). Sonohysterography allows for a more ... needle insertion) is usually minimal because the rectal wall is relatively insensitive to the pain in the ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... uses sound waves to produce pictures of a man’s prostate gland and to help diagnose symptoms such ... also called transrectal ultrasound, provides images of a man's prostate gland and surrounding tissue. The exam typically ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... pain ambiguous genitalia and anomalies of pelvic organs early or delayed puberty in girls Pelvic ultrasound is ... sensitive to motion, and an active or crying child can prolong the examination process. To ensure a ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... consist of a console containing a computer and electronics, a video display screen and a transducer that ... the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  16. Complex blood flow quantification using real-time in vivo vector flow ultrasound

    DEFF Research Database (Denmark)

    Pedersen, Mads Møller; Pihl, Michael Johannes; Per, Haugaard

    A new method to define and quantify complex blood flow is presented. The standard deviations of real-time in vivo vector flow angle estimates are used. Using vector flow ultrasound imaging both carotid bifurcations of two healthy volunteers were scanned. Scanning was performed with a 7.6 MHz linear...... transducer (8670, B-K Medical, Denmark) and a commercial vector flow ultrasound scanner (ProFocus 2202, B-K Medical). Eight video sequences of one cardiac cycle were obtained. In every frame boxes were placed to define the common carotid artery(box1) and the carotid bulb(box2). The standard deviation...... for the vector angle estimates was calculated for each box in every frame. For comparison three ultrasound experts evaluated the presence of complex flow in every box. The trial was blinded. For every sequence the mean standard deviation of the vector angle estimates were calculated for box1 {39...

  17. Adaptive Beamforming for Medical Ultrasound Imaging

    DEFF Research Database (Denmark)

    Holfort, Iben Kraglund

    This dissertation investigates the application of adaptive beamforming for medical ultrasound imaging. The investigations have been concentrated primarily on the Minimum Variance (MV) beamformer. A broadband implementation of theMV beamformer is described, and simulated data have been used...... to demonstrate the performance. The MV beamformer has been applied to different sets of ultrasound imaging sequences; synthetic aperture ultrasound imaging and plane wave ultrasound imaging. And an approach for applying MV optimized apodization weights on both the transmitting and the receiving apertures...

  18. Ultrasound diagnostics of thyroid diseases

    International Nuclear Information System (INIS)

    Kharchenko, Vladimir P.; Kotlyarov, Peter M.; Mogutov, Mikhail S.; Sencha, Alexander N.; Patrunov, Yury N.; Belyaev, Denis V.; Alexandrov, Yury K.

    2010-01-01

    This book is based on the authors' extensive practical experience in the use of modern ultrasound, and other radiological methods, in the diagnosis of thyroid diseases. The authors have analyzed more than 100,000 ultrasound examinations performed between 1995 and 2008 in patients with thyroid and parathyroid disease, as well as many thousands of diagnostic and therapeutic ultrasound-guided minimally invasive procedures. The opening chapters include discussion of current ultrasound techniques, pitfalls, and the specifics of ultrasound examination of the thyroid in children. Detailed attention is then devoted to findings in the normal thyroid and in the presence of diffuse and focal changes. Further chapters focus on such topics as ultrasound examination after thyroid surgery and ultrasound diagnosis of parathyroid disease, recurrent goiter, and neck masses. Ultrasound-guided minimally invasive techniques, such as fine-needle aspiration biopsy, percutaneous laser ablation, and ethanol and glucocorticoid injections, are considered in depth. This up-to-date and richly illustrated book will interest and assist specialists in ultrasound diagnostics, radiologists, endocrinologists, and neck surgeons. (orig.)

  19. Adaptive kernel regression for freehand 3D ultrasound reconstruction

    Science.gov (United States)

    Alshalalfah, Abdel-Latif; Daoud, Mohammad I.; Al-Najar, Mahasen

    2017-03-01

    Freehand three-dimensional (3D) ultrasound imaging enables low-cost and flexible 3D scanning of arbitrary-shaped organs, where the operator can freely move a two-dimensional (2D) ultrasound probe to acquire a sequence of tracked cross-sectional images of the anatomy. Often, the acquired 2D ultrasound images are irregularly and sparsely distributed in the 3D space. Several 3D reconstruction algorithms have been proposed to synthesize 3D ultrasound volumes based on the acquired 2D images. A challenging task during the reconstruction process is to preserve the texture patterns in the synthesized volume and ensure that all gaps in the volume are correctly filled. This paper presents an adaptive kernel regression algorithm that can effectively reconstruct high-quality freehand 3D ultrasound volumes. The algorithm employs a kernel regression model that enables nonparametric interpolation of the voxel gray-level values. The kernel size of the regression model is adaptively adjusted based on the characteristics of the voxel that is being interpolated. In particular, when the algorithm is employed to interpolate a voxel located in a region with dense ultrasound data samples, the size of the kernel is reduced to preserve the texture patterns. On the other hand, the size of the kernel is increased in areas that include large gaps to enable effective gap filling. The performance of the proposed algorithm was compared with seven previous interpolation approaches by synthesizing freehand 3D ultrasound volumes of a benign breast tumor. The experimental results show that the proposed algorithm outperforms the other interpolation approaches.

  20. Standardized ultrasound templates for diagnosing appendicitis reduce annual imaging costs.

    Science.gov (United States)

    Nordin, Andrew B; Sales, Stephen; Nielsen, Jason W; Adler, Brent; Bates, David Gregory; Kenney, Brian

    2018-01-01

    Ultrasound is preferred over computed tomography (CT) for diagnosing appendicitis in children to avoid undue radiation exposure. We previously reported our experience in instituting a standardized appendicitis ultrasound template, which decreased CT rates by 67.3%. In this analysis, we demonstrate the ongoing cost savings associated with using this template. Retrospective chart review for the time period preceding template implementation (June 2012-September 2012) was combined with prospective review through December 2015 for all patients in the emergency department receiving diagnostic imaging for appendicitis. The type of imaging was recorded, and imaging rates and ultrasound test statistics were calculated. Estimated annual imaging costs based on pretemplate ultrasound and CT utilization rates were compared with post-template annual costs to calculate annual and cumulative savings. In the pretemplate period, ultrasound and CT rates were 80.2% and 44.3%, respectively, resulting in a combined annual cost of $300,527.70. Similar calculations were performed for each succeeding year, accounting for changes in patient volume. Using pretemplate rates, our projected 2015 imaging cost was $371,402.86; however, our ultrasound rate had increased to 98.3%, whereas the CT rate declined to 9.6%, yielding an annual estimated cost of $224,853.00 and a savings of $146,549.86. Since implementation, annual savings have steadily increased for a cumulative cost savings of $336,683.83. Standardizing ultrasound reports for appendicitis not only reduces the use of CT scans and the associated radiation exposure but also decreases annual imaging costs despite increased numbers of imaging studies. Continued cost reduction may be possible by using diagnostic algorithms. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Computer-aided detection (CAD) of lung nodules in CT scans: radiologist performance and reading time with incremental CAD assistance

    International Nuclear Information System (INIS)

    Roos, Justus E.; Paik, David; Olsen, David; Liu, Emily G.; Leung, Ann N.; Mindelzun, Robert; Choudhury, Kingshuk R.; Napel, Sandy; Rubin, Geoffrey D.; Chow, Lawrence C.; Naidich, David P.

    2010-01-01

    The diagnostic performance of radiologists using incremental CAD assistance for lung nodule detection on CT and their temporal variation in performance during CAD evaluation was assessed. CAD was applied to 20 chest multidetector-row computed tomography (MDCT) scans containing 190 non-calcified ≥3-mm nodules. After free search, three radiologists independently evaluated a maximum of up to 50 CAD detections/patient. Multiple free-response ROC curves were generated for free search and successive CAD evaluation, by incrementally adding CAD detections one at a time to the radiologists' performance. The sensitivity for free search was 53% (range, 44%-59%) at 1.15 false positives (FP)/patient and increased with CAD to 69% (range, 59-82%) at 1.45 FP/patient. CAD evaluation initially resulted in a sharp rise in sensitivity of 14% with a minimal increase in FP over a time period of 100 s, followed by flattening of the sensitivity increase to only 2%. This transition resulted from a greater prevalence of true positive (TP) versus FP detections at early CAD evaluation and not by a temporal change in readers' performance. The time spent for TP (9.5 s ± 4.5 s) and false negative (FN) (8.4 s ± 6.7 s) detections was similar; FP decisions took two- to three-times longer (14.4 s ± 8.7 s) than true negative (TN) decisions (4.7 s ± 1.3 s). When CAD output is ordered by CAD score, an initial period of rapid performance improvement slows significantly over time because of non-uniformity in the distribution of TP CAD output and not to a changing reader performance over time. (orig.)

  2. An ultrasound system for simultaneous ultrasound hyperthermia and photon beam irradiation

    International Nuclear Information System (INIS)

    Straube, William L.; Moros, Eduardo G.; Low, Daniel A.; Klein, Eric E.; Willcut, Virgil M.; Myerson, Robert J.

    1996-01-01

    Purpose: An existing ultrasound system has been adapted for simultaneous use with external photon beam irradiation. The system is being used to investigate the potential for increased biological benefit of simultaneously combined hyperthermia and external beam irradiation with currently achievable temperature distributions. Methods and Materials: An existing clinical ultrasound system has been modified for simultaneous operation with a 60 Co teletherapy machine. The generator, thermometry system, computer, and applicators are located inside the treatment room, while the monitor and system control are located at the control console. Two approaches have been used clinically to combine the two modalities. In the first approach, an en-face setup is used in which the ultrasound beam and the photon beam travel through the same window of entry to the tumor. This is achieved by a reflecting system designed to deflect the ultrasound to the tumor while positioning the ultrasound transducer outside the radiation beam. The reflecting system consists of water and water-equivalent materials except for a 1 mm sheet of polished brass that is used as the reflector. The relative pressure fields were measured in water at the same distance from the ultrasound source using a scanning hydrophone with and without the reflector at the two operating frequencies of the device (1.0 and 3.4 MHz) for two applicators. Radiation dosimetry measurements were performed to determine the relationship between 60 Co irradiation through the reflector and absorbed dose. In the second approach the ultrasound and the radiation beam travel into the tumor from different windows of entry such that the radiation beam passes through no portion of the water bolus prior to entering the patient. We have termed this approach the orthogonal approach. For both approaches, the radiation fraction is given in the middle of an uninterrupted 60-min hyperthermia treatment. Results: The system modifications did not impair

  3. Robot-assisted ultrasound imaging: overview and development of a parallel telerobotic system.

    Science.gov (United States)

    Monfaredi, Reza; Wilson, Emmanuel; Azizi Koutenaei, Bamshad; Labrecque, Brendan; Leroy, Kristen; Goldie, James; Louis, Eric; Swerdlow, Daniel; Cleary, Kevin

    2015-02-01

    Ultrasound imaging is frequently used in medicine. The quality of ultrasound images is often dependent on the skill of the sonographer. Several researchers have proposed robotic systems to aid in ultrasound image acquisition. In this paper we first provide a short overview of robot-assisted ultrasound imaging (US). We categorize robot-assisted US imaging systems into three approaches: autonomous US imaging, teleoperated US imaging, and human-robot cooperation. For each approach several systems are introduced and briefly discussed. We then describe a compact six degree of freedom parallel mechanism telerobotic system for ultrasound imaging developed by our research team. The long-term goal of this work is to enable remote ultrasound scanning through teleoperation. This parallel mechanism allows for both translation and rotation of an ultrasound probe mounted on the top plate along with force control. Our experimental results confirmed good mechanical system performance with a positioning error of < 1 mm. Phantom experiments by a radiologist showed promising results with good image quality.

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ... of page What are the benefits vs. risks? Benefits Most ultrasound scanning is ... with your doctor, the medical facility staff and/or your insurance provider to get a better understanding of the ...

  5. Cranial Ultrasound/Head Ultrasound

    Science.gov (United States)

    ... used to screen for brain conditions associated with prematurity, such as bleeding or brain tissue damage as ... or crying child will slow the examination process. Large patients are more difficult to image by ultrasound, ...

  6. An analysis of whether surgeon-performed neck ultrasound can be used as the main localizing study in primary hyperparathyroidism.

    Science.gov (United States)

    Aliyev, Shamil; Agcaoglu, Orhan; Aksoy, Erol; Birsen, Onur; Milas, Mira; Mitchell, Jamie; Siperstein, Allan; Berber, Eren

    2014-11-01

    Tc-99 sestamibi (MIBI) scan is the imaging study most frequently used in primary hyperparathyroidism (PHP). Transcutaneous cervical ultrasonography (US) is the other modality used for preoperative localization. The aim of this study was to determine whether surgeon-performed neck US can be used as the primary localizing study in PHP. This was a prospective study of 1,000 consecutive patients with first-time, sporadic PHP who underwent parathyroidectomy at a tertiary academic center. All patients had surgeon-performed neck US and MIBI before bilateral neck exploration. The findings at exploration were 72% single adenoma, 15% double adenoma, and 13% hyperplasia. When US suggested single-gland disease (n = 842), MIBI was concordant in 82.5%, discordant and false in 8%, negative in 7%, and discordant but correct in 2.5%. When US suggested multigland disease (n = 68), MIBI was concordant in 47%, discordant and false in 41%, and negative in 12%. When US was negative (n = 90), MIBI was positive and correct in 43%, negative in 31%, and positive but false in 26%. Surgeon-performed neck US identified unrecognized thyroid nodules in 326 patients (33%), which led to fine-needle aspiration biopsy in 161 (49%) patients and thyroid surgery in 103 (32%) patients, with a final diagnosis of thyroid cancer in 24 (7%) patients. Our results show that MIBI provides additional useful information in only a minority of patients with a positive US in PHP. Nevertheless, MIBI benefits about half of patients with a negative US. Because one-third of this patient population has unrecognized thyroid nodules as well, we propose that the most cost-effective algorithm would be to do US first and reserve MIBI for US-negative cases. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart ... Articles and Media Angioplasty and Vascular Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ... ultrasound study may be part of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... What are the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and ... be heard with every heartbeat. top of page What are some common uses of the procedure? Ultrasound ...

  11. The clinical importance and prediction of steal following femoro-femoral cross-over bypass: study of the donor iliac artery by intravascular ultrasound, arteriography, duplex scanning and pressure measurements

    DEFF Research Database (Denmark)

    Vogt, K C; Rasmussen, J G; Schroeder, T V

    2000-01-01

    to evaluate the clinical significance of the steal phenomenon following femoro-femoral bypass, and whether the addition of intravascular ultrasound (IVUS) to the established examinations of the donor iliac artery can improve the prediction of patients who will develop steal.......to evaluate the clinical significance of the steal phenomenon following femoro-femoral bypass, and whether the addition of intravascular ultrasound (IVUS) to the established examinations of the donor iliac artery can improve the prediction of patients who will develop steal....

  12. The Lunula: An ultrasound imaging approach

    International Nuclear Information System (INIS)

    Choi, Soo Jung; Shin, Myung Jin; Kim, Sung Moon; Ahn, Joong Mo

    2001-01-01

    The lunula is the white, half-moon-shaped area seen on some, but not all nails. Usually the lunula is the topographic marker of the distal part of the nail matrix, and known to have the ability of nail production. Ultrasonographic imaging of the lunula has not been reported before. This study was undertaken to demonstrate normal ultrasonographic features of the lunula. Ultrasonographic examination of the lunula was performed in the right thumb of 20 healthy volunteers (10M, 10F, mean age 30, range 26-36 years) with a real-time, high-resolution ultrasound unit (Sequoia 512, Acuson, Mountain view, CA, USA) with 8-15 MHz linear transducers. Gray scale color, and special Doppler imagings were performed with longitudinal scanning. The lunula was not seen inspection in three of the 20 volunteers. The mean size of the lunula in the other 17 volumteen was 3.31 ± 1.24 mm (range 2-6.2 mm). Gray scale ultrasound imaging showed the lunula; ovoid shaped hypo-echoic zone in proximal fingernail in 18 of 20 volunteers (mean size, 6.74 ± 0.98 mm, range 5-8.8 mm). In two of 20 volunteers, the lunula was indistinct on gray scale ultrasound examination. However, all lunula were identifiable on color Doppler imaging by detecting vascularity within the lunula. Spectral wave pattern of the lunula was a bi-directional pulsatile wave. Peak velocity was within 5-15 m/sec (mean 8 m/sec). The lunula is identifiable on ultrasound examination as a hyper-vascular, ovoid shaped, hypo-echoic zone in proximal fingernail. This normal structure should not be misinterpreted as an abnormal sub-ungual lesion.

  13. Quality of pediatric abdominal CT scans performed at a dedicated children's hospital and its referring institutions: a multifactorial evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Snow, Aisling [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Our Lady' s Children' s Hospital, Department of Radiology, Dublin (Ireland); Milliren, Carly E.; Graham, Dionne A. [Boston Children' s Hospital, Program for Patient Safety and Quality, Boston, MA (United States); Callahan, Michael J.; MacDougall, Robert D.; Robertson, Richard L.; Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States)

    2017-04-15

    Pediatric patients requiring transfer to a dedicated children's hospital from an outside institution may undergo CT imaging as part of their evaluation. Whether this imaging is performed prior to or after transfer has been shown to impact the radiation dose imparted to the patient. Other quality variables could also be affected by the pediatric experience and expertise of the scanning institution. To identify differences in quality between abdominal CT scans and reports performed at a dedicated children's hospital, and those performed at referring institutions. Fifty consecutive pediatric abdominal CT scans performed at outside institutions were matched (for age, gender and indication) with 50 CT scans performed at a dedicated freestanding children's hospital. We analyzed the scans for technical parameters, report findings, correlation with final clinical diagnosis, and clinical utility. Technical evaluation included use of intravenous and oral contrast agents, anatomical coverage, number of scan phases and size-specific dose estimate (SSDE) for each scan. Outside institution scans were re-reported when the child was admitted to the children's hospital; they were also re-interpreted for this study by children's hospital radiologists who were provided with only the referral information given in the outside institution's report. Anonymized original outside institutional reports and children's hospital admission re-reports were analyzed by two emergency medicine physicians for ease of understanding, degree to which the clinical question was answered, and level of confidence in the report. Mean SSDE was lower (8.68) for children's hospital scans, as compared to outside institution scans (13.29, P = 0.03). Concordance with final clinical diagnosis was significantly lower for original outside institution reports (38/48, 79%) than for both the admission and study children's hospital reports (48/50, 96%; P = 0.005). Children

  14. Ultrasound surveillance of endovascular aneurysm repair: a safe modality versus computed tomography.

    Science.gov (United States)

    Collins, John T; Boros, Michael J; Combs, Kristin

    2007-11-01

    Routine ultrasound surveillance is adequate and safe for monitoring endovascular aneurysm repairs (EVARs). A retrospective chart review including 160 endograft patients was performed from August 2000 to September 2005. All ultrasound examinations (n = 359) were performed by a board-certified vascular surgery group's accredited laboratory. Registered vascular technologists utilized the same equipment consisting of Siemens Antares high-definition ultrasonography with tissue harmonics and color flow Doppler. An identical protocol was followed by each technologist: scan body and both limbs of the endograft and distal iliac vessels, measure anterior-posterior aneurysm sac size, and detect intrasac pulsatility and color flow. Statistical analysis utilized Pearson's correlation coefficient and the paired t-test. Forty-one endoleaks were discovered out of the 359 exams (11.4%). There were type I (7, 17%), type II (26, 63%), and combined type I with type II (8, 20%) endoleaks. Correlation with computed tomography (CT) was obtained in 35 of these cases. CT discovered three endoleaks that were not seen with ultrasound. However, these particular ultrasound exams were inadequate due to additional factors (bowel gas, body habitus, hernia), which prompted CT investigation and, hence, endoleak discovery. Of the 41 endoleaks found on ultrasound, only 14 were seen on CT. Specifically, 26 type II endoleaks were seen with ultrasound versus only nine during CT. Additional factors addressed included comparison between ultrasound and CT of residual aneurysm sac measurements and conditions limiting ultrasound examination. Although criticized in the past, color flow ultrasonography is a safe and effective modality for surveillance of aortic endografts. Utilizing ultrasound to analyze abdominal aortic aneurysm (AAA) sac dimensions and endoleak detection is statistically sound for screening AAA status post-EVAR.

  15. Nuclear Scans

    Science.gov (United States)

    Nuclear scans use radioactive substances to see structures and functions inside your body. They use a special ... images. Most scans take 20 to 45 minutes. Nuclear scans can help doctors diagnose many conditions, including ...

  16. Volumetric scans of wind turbine wakes performed with three simultaneous wind LiDARs under different atmospheric stability regimes

    International Nuclear Information System (INIS)

    Iungo, Giacomo Valerio; Porté-Agel, Fernando

    2014-01-01

    Aerodynamic optimization of wind farm layout is a crucial task to reduce wake effects on downstream wind turbines, thus to maximize wind power harvesting. However, downstream evolution and recovery of wind turbine wakes are strongly affected by the characteristics of the incoming atmospheric boundary layer (ABL) flow, such as wind shear and turbulence intensity, which are in turn affected by the ABL thermal stability. In order to characterize the downstream evolution of wakes produced by full-scale wind turbines under different atmospheric conditions, wind velocity measurements were performed with three wind LiDARs. The volumetric scans are performed by continuously sweeping azimuthal and elevation angles of the LiDARs in order to cover a 3D volume that includes the wind turbine wake. The minimum wake velocity deficit is then evaluated as a function of the downstream location for different atmospheric conditions. It is observed that the ABL thermal stability has a significant effect on the wake evolution, and the wake recovers faster under convective conditions

  17. The Ghanaian Woman's experience and perception of ultrasound use in antenatal care

    International Nuclear Information System (INIS)

    Mensah, Y. B.; Nkyekyer, K.; Mensah, K.

    2014-01-01

    The objective of this study is to evaluate how Ghanaian women perceive the use, and their assessment of the experience, of antenatal ultrasound scanning. A cross-sectional study, using interviewer administered questionnaire, from 25th February to 16th April, 2011 was conducted at the Obstetrics Units of Korle Bu Teaching Hospital, Accra, University of Ghana Hospital, Legon and Ga South District Hospital, Weija. A total of 337 clients were randomly selected after delivery and interviewed. Issues addressed included why women went for antenatal ultrasound, their knowledge of the uses of ultrasound in pregnancy, information provided by health care providers, clients’ eagerness to know the sex of their fetuses, and their overall assessment of the ultrasound scanning experience. The results of this study showed that the mean number of scans was 2.2(1.1). Most were performed on the request of a doctor or midwife; 154(45.7%) were not told the reasons for the request and 185(54.9%) did not have the results explained to them. For 239(70.9%) women the sonographer did not explain the procedure before the examination; 89(26.4%) were allowed to ask questions and 61(18.1%) were allowed to see their fetuses on the monitor. One hundred and sixty respondents (47.5%) asked for and were told the sex of their fetuses, with accuracy at delivery of 86.5%. Most respondents perceived antenatal ultrasound as a useful tool. There is lack of information flow from health care providers to clients concerning the indications for the ultrasound, the processes involved and the results of the procedure. Improvements in these areas are needed to enhance the experience of antenatal ultrasound among Ghanaian women

  18. Influence of case-based e-learning on students' performance in point-of-care ultrasound courses: a randomized trial.

    Science.gov (United States)

    Hempel, Dorothea; Sinnathurai, Sivajini; Haunhorst, Stephanie; Seibel, Armin; Michels, Guido; Heringer, Frank; Recker, Florian; Breitkreutz, Raoul

    2016-08-01

    Theoretical knowledge, visual perception, and sensorimotor skills are key elements in ultrasound education. Classroom-based presentations are used routinely to teach theoretical knowledge, whereas visual perception and sensorimotor skills typically require hands-on training (HT). We aimed to compare the effect of classroom-based lectures versus a case-based e-learning (based on clinical cases only) on the hands-on performance of trainees during an emergency ultrasound course. This is a randomized, controlled, parallel-group study. Sixty-two medical students were randomized into two groups [group 1 (G1) and group 2 (G2)]. G1 (n=29) was subjected to a precourse e-learning, based on 14 short screencasts (each 5 min), an on-site discussion (60 min), and a standardized HT session on the day of the course. G2 (n=31) received classroom-based presentations on the day of the course before an identical HT session. Both groups completed a multiple-choice (MC) pretest (test A), a practical postcourse test (objective structured clinical exam), and MC tests directly after the HT (test B) and 1 day after the course (test C). The Mann-Whitney U-test was used for statistical analysis. G1 performed markedly better in test A (median 84.2, 25%; 75% percentile: 68.5; 92.2) compared with G2 (65.8; 53.8; 80.4), who had not participated in case-based e-learning (P=0.0009). No differences were found in the objective structured clinical exam, test B, and test C. e-learning exclusively based on clinical cases is an effective method of education in preparation for HT sessions and can reduce attendance time in ultrasound courses.

  19. Therapeutic ultrasound

    International Nuclear Information System (INIS)

    Crum, Lawrence A

    2004-01-01

    The use of ultrasound in medicine is now quite commonplace, especially with the recent introduction of small, portable and relatively inexpensive, hand-held diagnostic imaging devices. Moreover, ultrasound has expanded beyond the imaging realm, with methods and applications extending to novel therapeutic and surgical uses. These applications broadly include: tissue ablation, acoustocautery, lipoplasty, site-specific and ultrasound mediated drug activity, extracorporeal lithotripsy, and the enhancement of natural physiological functions such as wound healing and tissue regeneration. A particularly attractive aspect of this technology is that diagnostic and therapeutic systems can be combined to produce totally non-invasive, imageguided therapy. This general lecture will review a number of these exciting new applications of ultrasound and address some of the basic scientific questions and future challenges in developing these methods and technologies for general use in our society. We shall particularly emphasize the use of High Intensity Focused Ultrasound (HIFU) in the treatment of benign and malignant tumors as well as the introduction of acoustic hemostasis, especially in organs which are difficult to treat using conventional medical and surgical techniques. (amum lecture)

  20. Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience

    Directory of Open Access Journals (Sweden)

    Michael O. Harris-Love

    2016-06-01

    Full Text Available Background. Quantitative ultrasound measures are influenced by multiple external factors including examiner scanning force. Force feedback may foster the acquisition of reliable morphometry measures under a variety of scanning conditions. The purpose of this study was to determine the reliability of force-feedback image acquisition and morphometry over a range of examiner-generated forces using a muscle tissue-mimicking ultrasound phantom. Methods. Sixty material thickness measures were acquired from a muscle tissue mimicking phantom using B-mode ultrasound scanning by six examiners with varied experience levels (i.e., experienced, intermediate, and novice. Estimates of interrater reliability and measurement error with force feedback scanning were determined for the examiners. In addition, criterion-based reliability was determined using material deformation values across a range of examiner scanning forces (1–10 Newtons via automated and manually acquired image capture methods using force feedback. Results. All examiners demonstrated acceptable interrater reliability (intraclass correlation coefficient, ICC = .98, p .90, p < .001, independent of their level of experience. The measurement error among all examiners was 1.5%–2.9% across all applied stress conditions. Conclusion. Manual image capture with force feedback may aid the reliability of morphometry measures across a range of examiner scanning forces, and allow for consistent performance among examiners with differing levels of experience.

  1. A comparison of portable ultrasound and fully-equipped clinical ultrasound unit in the thyroid size measurement of the Indo-Pacific bottlenose dolphin.

    Directory of Open Access Journals (Sweden)

    Brian C W Kot

    Full Text Available Measurement of thyroid size and volume is a useful clinical parameter in both human and veterinary medicine, particularly for diagnosing thyroid diseases and guiding corrective therapy. Procuring a fully-equipped clinical ultrasound unit (FCUS may be difficult in most veterinary settings. The present study evaluated the inter-equipment variability in dolphin thyroid ultrasound measurements between a portable ultrasound unit (PUS and a FCUS; for both units, repeatability was also assessed. Thyroid ultrasound examinations were performed on 15 apparently healthy bottlenose dolphins with both PUS and FCUS under identical scanning conditions. There was a high level of agreement between the two ultrasound units in dolphin thyroid measurements (ICC = 0.859-0.976. A high intra-operator repeatability in thyroid measurements was found (PUS: ICC = 0.854-0.984, FCUS: ICC = 0.709-0.954. As a conclusion, no substantial inter-equipment variability was found between PUS and FCUS in dolphin thyroid size measurements under identical scanning conditions, supporting further application of PUS for quantitative analyses of dolphin thyroid gland in both research and clinical practices at aquarium settings.

  2. Costs and role of ultrasound follow-up of polytrauma patients after initial computed tomography

    International Nuclear Information System (INIS)

    Maurer, M.H.; Winkler, A.; Powerski, M.J.; Elgeti, F.; Huppertz, A.; Roettgen, R.; Marnitz, T.; Wichlas, F.

    2012-01-01

    Purpose: To assess the costs and diagnostic gain of abdominal ultrasound follow-up of polytrauma patients initially examined by whole-body computed tomography (CT). Materials and Methods: A total of 176 patients with suspected multiple trauma (126 men, 50 women; age 43.5 ± 17.4 years) were retrospectively analyzed with regard to supplementary and new findings obtained by ultrasound follow-up compared with the results of exploratory FAST (focused assessment with sonography for trauma) at admission and the findings of whole-body CT. A process model was used to document the staff, materials, and total costs of the ultrasound follow-up examinations. Results: FAST yielded 26 abdominal findings (organ injury and/or free intra-abdominal fluid) in 19 patients, while the abdominal scan of whole-body CT revealed 32 findings in 25 patients. FAST had 81 % sensitivity and 100 % specificity. Follow-up ultrasound examinations revealed new findings in 2 of the 25 patients with abdominal injuries detected with initial CT. In the 151 patients without abdominal injuries in the initial CT scan, ultrasound follow-up did not yield any supplementary or new findings. The total costs of an ultrasound follow-up examination were EUR 28.93. The total costs of all follow-up ultrasound examinations performed in the study population were EUR 5658.23. Conclusion: Follow-up abdominal ultrasound yields only a low overall diagnostic gain in polytrauma patients in whom initial CT fails to detect any abdominal injuries but incurs high personnel expenses for radiological departments. (orig.)

  3. Diagnostic Performance of Three Phase Bone Scan for Complex Regional Pain Syndrome Type 1 with Optimally Modified Image Criteria

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyun Woo; Paeng, Jin Chul; Nahm, Francins Sahngun; Kim, Seog Gyun; Zehra, Tanzeel; Oh, So Won; Lee, Hyo Sang; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    2011-12-15

    Although the three phase bone scan (TBPS) is one of the widely used imaging studies for diagnosing complex regional pain syndrome type 1 (CRPS 1), there is some controversy regarding the TPBS image criteria for CRPS 1. In this study, we modified the image criteria using image pattern and quantitative analysis in the patients diagnosed using the most recent consensus clinical diagnostic criteria. The study included 140 patients with suspected CRPS 1 (CRPS 1, n=79; non CRPS, n=61; mean age 39{+-}15 years) who underwent TPBS. The clinical diagnostic criteria for CRPS 1 revised by the Budapest consensus group were used for confirmative diagnosis. Patients were classified according to flow/pool and delayed uptake (DU) image patterns, and the time interval between the initiating event and TPBS (TI{sup eventscan)}. Quantitative analysis for lesion to contralateral ratio (LCR) was performed. Modified TPBS image criteria were created and evaluated for optimal diagnostic performance. Both increased and decreased periarticular DU were significant image findings for CRPS 1 (CRPS 1 positive rate=73% in the increased DU group, 75% in the decreased DU group). The TI{sup eventscand}id not differ significantly between the different image pattern groups. Quantitative analysis revealed an LCR of 1.43 was the optimal cutoff value for CRPS 1 and diagnostic performance was significantly improved in the increased DU group (area under the curve=0.732). Given the modified image criteria, the sensitivity and specificity of TPBS for diagnosing CRPS 1 were 80% and 72%, respectively. Optimally modified TPBS image criteria for CRPS 1 were suggested using image pattern and quantitative analysis. With the criteria, TPBS is an effective imaging study for CRPS 1 even with the most recent consensus clinical diagnostic criteria.

  4. Diagnostic Performance of Three Phase Bone Scan for Complex Regional Pain Syndrome Type 1 with Optimally Modified Image Criteria

    International Nuclear Information System (INIS)

    Kwon, Hyun Woo; Paeng, Jin Chul; Nahm, Francins Sahngun; Kim, Seog Gyun; Zehra, Tanzeel; Oh, So Won; Lee, Hyo Sang; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo

    2011-01-01

    Although the three phase bone scan (TBPS) is one of the widely used imaging studies for diagnosing complex regional pain syndrome type 1 (CRPS 1), there is some controversy regarding the TPBS image criteria for CRPS 1. In this study, we modified the image criteria using image pattern and quantitative analysis in the patients diagnosed using the most recent consensus clinical diagnostic criteria. The study included 140 patients with suspected CRPS 1 (CRPS 1, n=79; non CRPS, n=61; mean age 39±15 years) who underwent TPBS. The clinical diagnostic criteria for CRPS 1 revised by the Budapest consensus group were used for confirmative diagnosis. Patients were classified according to flow/pool and delayed uptake (DU) image patterns, and the time interval between the initiating event and TPBS (TI eventscan) . Quantitative analysis for lesion to contralateral ratio (LCR) was performed. Modified TPBS image criteria were created and evaluated for optimal diagnostic performance. Both increased and decreased periarticular DU were significant image findings for CRPS 1 (CRPS 1 positive rate=73% in the increased DU group, 75% in the decreased DU group). The TI eventscand id not differ significantly between the different image pattern groups. Quantitative analysis revealed an LCR of 1.43 was the optimal cutoff value for CRPS 1 and diagnostic performance was significantly improved in the increased DU group (area under the curve=0.732). Given the modified image criteria, the sensitivity and specificity of TPBS for diagnosing CRPS 1 were 80% and 72%, respectively. Optimally modified TPBS image criteria for CRPS 1 were suggested using image pattern and quantitative analysis. With the criteria, TPBS is an effective imaging study for CRPS 1 even with the most recent consensus clinical diagnostic criteria.

  5. Performance of third-trimester ultrasound for prediction of small-for-gestational-age neonates and evaluation of contingency screening policies.

    Science.gov (United States)

    Souka, A P; Papastefanou, I; Pilalis, A; Michalitsi, V; Kassanos, D

    2012-05-01

    To assess the performance of third-trimester fetal biometry and fetal Doppler studies for the prediction of small-for-gestational-age (SGA) neonates, and to explore contingency strategies using a first-trimester prediction model based on maternal and fetal parameters and third-trimester ultrasound. This was an observational cross-sectional study of uncomplicated singleton pregnancies. Risk assessment for chromosomal abnormality was carried out in 4702 pregnancies using a combination of ultrasound markers (fetal nuchal translucency thickness (NT) and nasal bone assessment) and biochemistry (free beta-human chorionic gonadotropin (β-hCG) and pregnancy-associated plasma protein-A (PAPP-A)) at 11 to 13 + 6 weeks. Maternal demographic characteristics and method of conception were recorded. Third-trimester (30-34 weeks) fetal biometry (biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC) and femur length (FL)) and umbilical artery (UA) and middle cerebral artery Doppler studies were performed routinely in a subgroup (n = 2310). Reference ranges for birth weight were constructed using the cohort of 4702 women, and neonates were classified as small (SGA, ≤ 5th centile) or appropriate (AGA) for gestational age. First-trimester, third-trimester and integrated first- and third-trimester prediction models for SGA were constructed using regression analysis and three different contingency strategies of rescanning in the third trimester were investigated. According to the areas under the receiver-operating characteristics curves (AUCs), AC (AUC = 0.85) and ultrasound-estimated fetal weight (EFW, AUC = 0.87) were equally good predictors of SGA. The model was marginally improved by the addition of UA Doppler, smoking status and first-trimester indices (free β-hCG and PAPP-A multiples of the median) (combined model, AUC = 0.88), but the difference was not statistically significant. A contingency strategy of rescanning 50% of the population in the

  6. Impact of number of repeated scans on model observer performance for a low-contrast detection task in computed tomography.

    Science.gov (United States)

    Ma, Chi; Yu, Lifeng; Chen, Baiyu; Favazza, Christopher; Leng, Shuai; McCollough, Cynthia

    2016-04-01

    Channelized Hotelling observer (CHO) models have been shown to correlate well with human observers for several phantom-based detection/classification tasks in clinical computed tomography (CT). A large number of repeated scans were used to achieve an accurate estimate of the model's template. The purpose of this study is to investigate how the experimental and CHO model parameters affect the minimum required number of repeated scans. A phantom containing 21 low-contrast objects was scanned on a 128-slice CT scanner at three dose levels. Each scan was repeated 100 times. For each experimental configuration, the low-contrast detectability, quantified as the area under receiver operating characteristic curve, [Formula: see text], was calculated using a previously validated CHO with randomly selected subsets of scans, ranging from 10 to 100. Using [Formula: see text] from the 100 scans as the reference, the accuracy from a smaller number of scans was determined. Our results demonstrated that the minimum number of repeated scans increased when the radiation dose level decreased, object size and contrast level decreased, and the number of channels increased. As a general trend, it increased as the low-contrast detectability decreased. This study provides a basis for the experimental design of task-based image quality assessment in clinical CT using CHO.

  7. Determination of atenolol in human plasma using ionic-liquid-based ultrasound-assisted in situ solvent formation microextraction followed by high-performance liquid chromatography.

    Science.gov (United States)

    Zeeb, Mohsen; Farahani, Hadi; Papan, Mohammad Kazem

    2016-06-01

    An efficient analytical method called ionic-liquid-based ultrasound-assisted in situ solvent formation microextraction followed by high-performance liquid chromatography was developed for the determination of atenolol in human plasma. A hydrophobic ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) was formed by the addition of a hydrophilic ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate) to a sample solution containing an ion-pairing agent during microextraction. The analyte was extracted into the ionic liquid phase while the microextraction solvent was dispersed throughout the sample by utilizing ultrasound. The sample was then centrifuged, and the extracting phase retracted into the microsyringe and injected to liquid chromatography. After optimization, the calibration curve showed linearity in the range of 2-750 ng/mL with the regression coefficient corresponding to 0.998. The limits of detection (S/N = 3) and quantification (S/N = 10) were 0.5 and 2 ng/mL, respectively. A reasonable relative recovery range of 90-96.7% and satisfactory intra-assay (4.8-5.1%, n = 6) and interassay (5.0-5.6%, n = 9) precision along with a substantial sample clean-up demonstrated good performance of the procedure. It was applied for the determination of atenolol in human plasma after oral administration and some pharmacokinetic data were obtained. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... kidneys. top of page What are some common uses of the procedure? Abdominal ultrasound imaging is performed ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  9. Ultrasound Fracture Diagnosis in Space

    Data.gov (United States)

    National Aeronautics and Space Administration — This ground-based proposal accumulated high-level clinical evidence on the sensitivity and specificity of point of care ultrasound performed by expert and novice...

  10. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... kidneys. top of page What are some common uses of the procedure? Abdominal ultrasound imaging is performed ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  11. Role of B-scan ultrasonography in pre-operative cataract patients.

    Science.gov (United States)

    Qureshi, Manzoor A; Laghari, Khalida

    2010-01-01

    To visualize the posterior portion of eye globe in dense cataract patients with B scan ultrasound, and to find out any posterior segment lesion in such pre-operative cases. We performed diagnostic B-scan ultrasound on 750 cataract patients before surgery. This was a prospective diagnostic study which was conducted in the Department of Opthalmology, Liaquat University Eye Hospital, Hyderabad Sind, Pakistan from January 2007 to July 2007. Detailed history and some basic eye examination techniques, like slit lamp and tonometry were done in two groups of patients, traumatic (71) and non traumatic(679). Patients in the age range of 1 to 79 years of both sexes were included. Patients having already posterior segment lesions and those who had previous history of ocular surgery were excluded from the study. An ultrasound machine Nidek Echo Scan Model US-3300 with a probe of direct contact was used. Out of 750 patients, 90 patients had posterior segment lesions. Among traumatic group of 71 patients, 39 (55%) had positive posterior segment lesions, while in the non traumatic group of 679 patients, only 51 (7%) cases had positive posterior segment lesions. Out of the 90 positive cases, 25 (3%) had retinal detachment, 14 (2%) had posterior vitreous detachment, 24 (3%) had vitreous hemorrhage, 12 (2%) were asteroid hyolosis, while posterior staphyloma and intra-ocular foreign body were found with the frequency of 9 (1.2%) and 6 (1%), respectively. We concluded that two dimensional B-scan ultrasound can be one of the diagnostic tool for the detection of hidden posterior segment lesions and can be performed routinely in pre-operative cataract patients, as this would help in surgical planning. In cases, where a two dimensional B-scan is not sufficient or helpful. a three dimensional ultrasound would be justified.

  12. Adaptive optics scanning laser ophthalmoscope using liquid crystal on silicon spatial light modulator: Performance study with involuntary eye movement

    Science.gov (United States)

    Huang, Hongxin; Toyoda, Haruyoshi; Inoue, Takashi

    2017-09-01

    The performance of an adaptive optics scanning laser ophthalmoscope (AO-SLO) using a liquid crystal on silicon spatial light modulator and Shack-Hartmann wavefront sensor was investigated. The system achieved high-resolution and high-contrast images of human retinas by dynamic compensation for the aberrations in the eyes. Retinal structures such as photoreceptor cells, blood vessels, and nerve fiber bundles, as well as blood flow, could be observed in vivo. We also investigated involuntary eye movements and ascertained microsaccades and drifts using both the retinal images and the aberrations recorded simultaneously. Furthermore, we measured the interframe displacement of retinal images and found that during eye drift, the displacement has a linear relationship with the residual low-order aberration. The estimated duration and cumulative displacement of the drift were within the ranges estimated by a video tracking technique. The AO-SLO would not only be used for the early detection of eye diseases, but would also offer a new approach for involuntary eye movement research.

  13. Evaluation of Hydrate Inhibition Performance of Water-soluble Polymers using Torque Measurement and Differential Scanning Calorimeter

    International Nuclear Information System (INIS)

    Shin, Kyuchul; Park, Juwoon; Kim, Jakyung; Kim, Hyunho; Seo, Yutaek; Lee, Yohan; Seo, Yongwon

    2014-01-01

    In this work, hydrate inhibition performance of water-soluble polymers including pyrrolidone, caprolactam, acrylamide types were evaluated using torque measurement and high pressure differential scanning calorimeter (HP µ-DSC). The obtained experimental results suggest that the studied polymers represent the kinetic hydrate inhibition (KHI) performance. 0.5 wt% polyvinylcaprolactam (PVCap) solution shows the hydrate onset time of 34.4 min and subcooling temperature of 15.9 K, which is better KHI performance than that of pure water - hydrate onset time of 12.3 min and subcooling temperature of 6.0 K. 0.5 wt% polyvinylpyrrolidone (PVP) solution shows the hydrate onset time of 27.6 min and the subcooling temperature of 13.2 K while polyacrylamide-co-acrylic acid partial sodium salt (PAM-co-AA) solution shows less KHI performance than PVP solution at both 0.5 and 5.0 wt%. However, PAM-co-AA solution shows slow growth rate and low hydrate amount than PVCap. In addition to hydrate onset and growth condition, torque change with time was investigated as one of KHI evaluation methods. 0.5 wt% PVCap solution shows the lowest average torque of 6.4 N cm and 0.5 wt% PAM-co-AA solution shows the average torque of 7.2 N cm. For 0.5 wt% PVP solution, it increases 11.5 N cm and 5.0 wt% PAM-co-AA solution shows the maximum average torque of 13.4 N cm, which is similar to the average torque of pure water, 15.2 N cm. Judging from the experimental results obtained by both an autoclave and a HP µ-DSC, the PVCap solution shows the best performance among the KHIs in terms of delaying hydrate nucleation. From these results, it can be concluded that the torque change with time is useful to identify the flow ability of tested solution, and the further research on the inhibition of hydrate formation can be approached in various aspects using a HP µ-DSC

  14. Dichorionic twin ultrasound surveillance: sonography every 4 weeks significantly underperforms sonography every 2 weeks: results of the Prospective Multicenter ESPRiT Study.

    Science.gov (United States)

    Corcoran, Siobhan; Breathnach, Fionnuala; Burke, Gerard; McAuliffe, Fionnuala; Geary, Michael; Daly, Sean; Higgins, John; Hunter, Alyson; Morrison, John J; Higgins, Shane; Mahony, Rhona; Dicker, Patrick; Tully, Elizabeth; Malone, Fergal D

    2015-10-01

    A 2-week ultrasound scanning schedule for monochorionic twins is endorsed widely. There is a lack of robust data to inform a schedule for the surveillance of dichorionic gestations. We aimed to determine how ultrasound scanning that is performed at 2- or 4-week intervals (or every 4 weeks before 32 weeks' gestation and every 2 weeks thereafter) may impact the prenatal detection of fetal growth restriction (FGR) and ultimately influence timing of delivery. In a consecutive cohort of 789 dichorionic twin pregnancies that were recruited prospectively for the multicenter Evaluation of Sonographic Predictors of Restricted Growth in Twins study, ultrasound determination of fetal growth and interrogation of umbilical and middle cerebral artery Doppler scans were performed every 2 weeks from 24 weeks' gestation until delivery. Complete delivery and perinatal outcome data were recorded for all pregnancies. Where delivery was prompted by FGR, abnormal umbilical artery Doppler examination or poor biophysical profile and in the absence of ruptured membranes, onset of labor, preeclampsia, or antepartum hemorrhage, the delivery was considered "ultrasound-indicated." For ultrasound-indicated deliveries, detection probabilities for FGR/abnormal umbilical artery Doppler scans/poor biophysical were determined according to the interval between examinations, by the suppression if alternate examination data. Among 789 dichorionic twin pregnancies, 66 pairs (8%) had an "ultrasound indicated" delivery. Detection of FGR was reduced from 88-69%, and detection of abnormal umbilical artery Doppler was reduced from 82-62% when a 4-week ultrasound schedule was simulated. Both of these reductions reached statistical significance. There was a nonsignificant trend toward a reduction in the recording of oligohydramnios with a 4-week interval between examinations. This study suggests that the ultrasound surveillance program of every 2 weeks that is recommended currently for monochorionic twins

  15. Power ultrasound irradiation during the alkaline etching process of the 2024 aluminum alloy

    Science.gov (United States)

    Moutarlier, V.; Viennet, R.; Rolet, J.; Gigandet, M. P.; Hihn, J. Y.

    2015-11-01

    Prior to any surface treatment on an aluminum alloy, a surface preparation is necessary. This commonly consists in performing an alkaline etching followed by acid deoxidizing. In this work, the use of power ultrasound irradiation during the etching step on the 2024 aluminum alloy was studied. The etching rate was estimated by weight loss, and the alkaline film formed during the etching step was characterized by glow discharge optical emission spectrometry (GDOES) and scanning electron microscope (SEM). The benefit of power ultrasound during the etching step was confirmed by pitting potential measurement in NaCl solution after a post-treatment (anodizing).

  16. Contrast Enhanced Ultrasound of the Kidneys: What Is It Capable of?

    Directory of Open Access Journals (Sweden)

    Demosthenes D. Cokkinos

    2013-01-01

    Full Text Available One of the many imaging uses of contrast enhanced ultrasound (CEUS is studying a wide variety of kidney pathology, due to its ability to detect microvascular blood flow in real time without affecting renal function. CEUS enables dynamic assessment and quantification of microvascularisation up to capillary perfusion. The objective of this paper is to briefly refresh basic knowledge of ultrasound (US contrast agents’ physical properties, to study technical details of CEUS scanning in the kidneys, and to review the commonest renal indications for CEUS, with imaging examples in comparison to baseline unenhanced US and computed tomography when performed. Safety matters and limitations of CEUS of the kidneys are also discussed.

  17. Ultrasound findings in biliary system

    International Nuclear Information System (INIS)

    Park, Won Sik; Lee, Yong Woo; Cheung, Hwan

    1986-01-01

    In the liver and biliary system ultrasound has emerged as one of the most useful imaging techniques. It is usually the first radiological procedure selected and is often sufficient alone to enable a clinical decision to be made. Good result with ultrasound depend critically on expert scanning technique coupled with an understanding of tomographic anatomy and, of course, an appreciation of the clinical significance of any findings. In addition to we'd like to stress on the ultrasonical anatomy and for the technologist and also discuss about pathological part

  18. Negative predictive value of ultrasound in predicting tumor-free margins in specimen sonography

    International Nuclear Information System (INIS)

    Naz, S.; Hafeez, S.; Hussain, Z.; Hilal, K.

    2017-01-01

    Objective: To evaluate the success of ultrasound in post-excision specimen visualization, and negative predictive value of ultrasound for estimation of tumor-free margins using histopathology as the gold standard. Study Design: Cross-sectional analytical study. Place and Duration of Study: The Aga Khan University Hospital, Karachi, Pakistan, from May 2010 till January 2013. Methodology: Sonography of all breast nodules was done before and after exicision by two female radiologists with at least five years clinical experience. All surgeries were performed by the same referring breast surgeons. All nodules were non-palpable and had histopathology as well as specimen sonography performed at AKUH. Subjects were excluded, if histopathology was not available, post-procedure sonogram not done or done in another hospital and nodules that were not seen on ultrasound. After needle localization in 47 patients using ultrasound and in 7 patients using mammogram was done, sonogram was conducted in all 54 lesions. These were then assessed by ultrasound for detection of lesion and tumor-free margins in malignant lesion. Post-excision ultrasound was performed for the evaluation of lesion whether visualized or absent with localizing needle in situ, lesion dimensions, depth measurement between the superior margin of the lesion and its edge. Results: All 54 lesions were present on post-exicison scan, out of which 28 were documented as malignant and 26 as benign. Ultrasound declared all specimens as tumor-free. On histopathology, two lesions were documented as having tumor-positive margins and were proven to be invasive lobular carcinoma. Therefore, the negative predictive value of the specimen sonography for margin detection was 26/28 (92.8%). Conclusion: Ultrasound of the excised breast tumor specimen is a simple and reliable technique for confirmation of the tumor-free margins in non-palpable breast lesions. (author)

  19. 3D ultrasound imaging for prosthesis fabrication and diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, A.K.; Bow, W.J.; Strong, D.S. [and others

    1995-06-01

    The fabrication of a prosthetic socket for a below-the-knee amputee requires knowledge of the underlying bone structure in order to provide pressure relief for sensitive areas and support for load bearing areas. The goal is to enable the residual limb to bear pressure with greater ease and utility. Conventional methods of prosthesis fabrication are based on limited knowledge about the patient`s underlying bone structure. A 3D ultrasound imaging system was developed at Sandia National Laboratories. The imaging system provides information about the location of the bones in the residual limb along with the shape of the skin surface. Computer assisted design (CAD) software can use this data to design prosthetic sockets for amputees. Ultrasound was selected as the imaging modality. A computer model was developed to analyze the effect of the various scanning parameters and to assist in the design of the overall system. The 3D ultrasound imaging system combines off-the-shelf technology for image capturing, custom hardware, and control and image processing software to generate two types of image data -- volumetric and planar. Both volumetric and planar images reveal definition of skin and bone geometry with planar images providing details on muscle fascial planes, muscle/fat interfaces, and blood vessel definition. The 3D ultrasound imaging system was tested on 9 unilateral below-the- knee amputees. Image data was acquired from both the sound limb and the residual limb. The imaging system was operated in both volumetric and planar formats. An x-ray CT (Computed Tomography) scan was performed on each amputee for comparison. Results of the test indicate beneficial use of ultrasound to generate databases for fabrication of prostheses at a lower cost and with better initial fit as compared to manually fabricated prostheses.

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the prostate. help diagnose the cause of a man's infertility. A transrectal ultrasound of the prostate gland is typically used to help diagnose symptoms such as: a nodule felt by a physician during a routine physical exam or prostate cancer screening exam. an elevated ...